WorldWideScience

Sample records for instrumentation techniques utilizing

  1. Proceedings of the OECD/CSNI specialist meeting on advanced instrumentation and measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lehner, J [comp.

    1998-09-01

    In the last few years, tremendous advances in the local instrumentation technology for two-phase flow have been accomplished by the applications of new sensor techniques, optical or beam methods and electronic technology. The detailed measurements gave new insight to the true nature of local mechanisms of interfacial transfer between phases, interfacial structure and two-phase flow turbulent transfers. These new developments indicate that more accurate and reliable two-phase flow models can be obtained, if focused experiments are designed and performed by utilizing this advanced instrumentation. The purpose of this Specialist Meeting on Advanced Instrumentation and Measurement Techniques was to review the recent instrumentation developments and the relation between thermal-hydraulic codes and instrumentation capabilities. Four specific objectives were identified for this meeting: bring together international experts on instrumentation, experiments, and modeling; review recent developments in multiphase flow instrumentation; discuss the relation between modeling needs and instrumentation capabilities, and discuss future directions for instrumentation development, modeling, and experiments.

  2. Proceedings of the OECD/CSNI specialist meeting on advanced instrumentation and measurement techniques

    International Nuclear Information System (INIS)

    Lehner, J.

    1998-09-01

    In the last few years, tremendous advances in the local instrumentation technology for two-phase flow have been accomplished by the applications of new sensor techniques, optical or beam methods and electronic technology. The detailed measurements gave new insight to the true nature of local mechanisms of interfacial transfer between phases, interfacial structure and two-phase flow turbulent transfers. These new developments indicate that more accurate and reliable two-phase flow models can be obtained, if focused experiments are designed and performed by utilizing this advanced instrumentation. The purpose of this Specialist Meeting on Advanced Instrumentation and Measurement Techniques was to review the recent instrumentation developments and the relation between thermal-hydraulic codes and instrumentation capabilities. Four specific objectives were identified for this meeting: bring together international experts on instrumentation, experiments, and modeling; review recent developments in multiphase flow instrumentation; discuss the relation between modeling needs and instrumentation capabilities, and discuss future directions for instrumentation development, modeling, and experiments

  3. Introduction to focused ion beams instrumentation, theory, techniques and practice

    CERN Document Server

    Giannuzzi, Lucille A

    2005-01-01

    The focused ion beam (FIB) instrument has experienced an intensive period of maturation since its inception. Numerous new techniques and applications have been brought to fruition, and over the past few years, the FIB has gained acceptance as more than just an expensive sample preparation tool. It has taken its place among the suite of other instruments commonly available in analytical and forensic laboratories, universities, geological, medical and biological research institutions, and manufacturing plants. Although the utility of the FIB is not limited to the preparation of specimens for subsequent analysis by other analytical techniques, it has revolutionized the area of TEM specimen preparation. The FIB has also been used to prepare samples for numerous other analytical techniques, and offers a wide range of other capabilities. While the mainstream of FIB usage remains within the semiconductor industry, FIB usage has expanded to applications in metallurgy, ceramics, composites, polymers, geology, art, bio...

  4. Instrument setpoints and data gathering techniques

    International Nuclear Information System (INIS)

    Leong, J.L.; Ornellas, R.P.; Atkinson, J.L.; Gross, R.S.

    1994-01-01

    Setpoint calculation project sizes vary greatly depending upon the level of effort required and can generally be classified as small or large depending on the number of setpoint calculations required. Small projects usually consist of new system upgrades, power uprates, and the utility's response to industry wide issues and concerns, and require between 10 and 120 setpoint calculations. Large projects usually involve design basis reconstitutions and the complete recalculating of all setpoints prioritized on system or safety related bases. Both large and small project schedules are usually directly tied to Nuclear Regulatory Commission (NRC) commitment dates and it is not uncommon for a large project to take 2 to 3 years to complete. Setpoint calculation projects have historically been performed by the brute force technique employing a variety of methodologies. The brute force technique typically employed today involves putting together a project team large enough to perform all the scheduled setpoint calculations. Setpoint calculations vary in size and complexity and, therefore, may require a wide range of man-hours of a qualified instrument setpoint engineer's time to perform instrument input data retrieval, resolve conflicting input data values, and complete the calculation. The actual time to perform the setpoint calculation using a computer program to calculate results is relatively small in comparison with the time required for data collection and the preparation of supporting documentation. Three major issues have traditionally plagued setpoint calculation projects: data collection; methodology; and incomplete and inconsistent calculations. These traditional problems are addressed and an innovative solution to performing instrument setpoint calculation projects is presented. Through the use of the POWRTRAK database and powerful computer software programs, a new solution to an old and persistent industry challenge is established

  5. Management of broken instrument by file bypass technique

    Directory of Open Access Journals (Sweden)

    Sultana Parveen

    2017-02-01

    Full Text Available Different devices and techniques have been developed to retrieve fractured instruments during the endodontic procedures. This case report describes the management of a broken instrument, which was accidentally broken during cleaning and shaping of the root canal in right 2nd molar tooth. A # 25 stainless steel K-file was separated in mesiobuccal canal of the treated tooth. At first, a radiograph was taken to confirm the level of separation of the instrument. The instrument was found to be separated at the apical 3rd of the mesial canal and then file bypass technique was performed. Calcium hydroxide dressing was given for 7 days followed by obturation with guttapercha cone and zinc oxide eugenol sealer in lateral condensation technique. It can be concluded that bypass technique can be considered as simple and effective technique for the management of broken instrument into the root canal.

  6. Single incision laparoscopic cholecystectomy using the one-incision three-trocar technique with all straight instruments: how I do it?

    Institute of Scientific and Technical Information of China (English)

    Hongyi Cui

    2011-01-01

    Single incision laparoscopic surgery (SILS) is a novel minimally invasive surgical technique that is gaining popularity around the world.One of the most commonly performed procedures is single incision laparoscopic cholecystectomy (SILC).Most reported techniques utilize special purpose-made access port and articulating instruments,rendering the procedure costly and difficult to learn.This article provides a stepwise description of SILC technique using all straight instruments without the need for a special port.It aims to shorten the learning curve for surgeons wishing to adopt a safe and cost-effective SILC technique to their practice.

  7. Soil analysis. Modern instrumental technique

    International Nuclear Information System (INIS)

    Smith, K.A.

    1993-01-01

    This book covers traditional methods of analysis and specialist monographs on individual instrumental techniques, which are usually not written with soil or plant analysis specifically in mind. The principles of the techniques are combined with discussions of sample preparation and matrix problems, and critical reviews of applications in soil science and related disciplines. Individual chapters are processed separately for inclusion in the appropriate data bases

  8. Principles of fluorescence techniques

    CERN Document Server

    2016-01-01

    Fluorescence techniques are being used and applied increasingly in academics and industry. The Principles of Fluorescence Techniques course will outline the basic concepts of fluorescence techniques and the successful utilization of the currently available commercial instrumentation. The course is designed for students who utilize fluorescence techniques and instrumentation and for researchers and industrial scientists who wish to deepen their knowledge of fluorescence applications. Key scientists in the field will deliver theoretical lectures. The lectures will be complemented by the direct utilization of steady-state and lifetime fluorescence instrumentation and confocal microscopy for FLIM and FRET applications provided by leading companies.

  9. Instrumental analytical techniques in geochemistry: Requirements and applications

    International Nuclear Information System (INIS)

    Willis, J.P.

    1986-01-01

    Geochemists must analyse an extremely wide range of terrestrial and planetary materials. The instrumental techniques necessary to cope with this difficult task are considered. The most important analytical techniques in use by the geochemist today are AAS, ICP-OES, INAA, MSID and XRFS, and the electron microscope for in situ mineral analysis. Some applications of these techniques to solving major problems in geochemistry are discussed. The importance of certified reference materials and of high quality geochemical data are emphasized. It is concluded that the general quality of trace element data has improved over the past 25 years, as a direct result of the application of modern instrumental techniques. Surprisingly, the quality of data reported for certain major elements has deteriorated over that time, when compared with data obtainable by classical chemical methods. Predictions are made concerning the instrumentation needs of the next generation of geochemists. (orig.) [de

  10. Diabetes and quality of life: Comparing results from utility instruments and Diabetes-39.

    Science.gov (United States)

    Chen, Gang; Iezzi, Angelo; McKie, John; Khan, Munir A; Richardson, Jeff

    2015-08-01

    To compare the Diabetes-39 (D-39) with six multi-attribute utility (MAU) instruments (15D, AQoL-8D, EQ-5D, HUI3, QWB, and SF-6D), and to develop mapping algorithms which could be used to transform the D-39 scores into the MAU scores. Self-reported diabetes sufferers (N=924) and members of the healthy public (N=1760), aged 18 years and over, were recruited from 6 countries (Australia 18%, USA 18%, UK 17%, Canada 16%, Norway 16%, and Germany 15%). Apart from the QWB which was distributed normally, non-parametric rank tests were used to compare subgroup utilities and D-39 scores. Mapping algorithms were estimated using ordinary least squares (OLS) and generalised linear models (GLM). MAU instruments discriminated between diabetes patients and the healthy public; however, utilities varied between instruments. The 15D, SF-6D, AQoL-8D had the strongest correlations with the D-39. Except for the HUI3, there were significant differences by gender. Mapping algorithms based on the OLS estimator consistently gave better goodness-of-fit results. The mean absolute error (MAE) values ranged from 0.061 to 0.147, the root mean square error (RMSE) values 0.083 to 0.198, and the R-square statistics 0.428 and 0.610. Based on MAE and RMSE values the preferred mapping is D-39 into 15D. R-square statistics and the range of predicted utilities indicate the preferred mapping is D-39 into AQoL-8D. Utilities estimated from different MAU instruments differ significantly and the outcome of a study could depend upon the instrument used. The algorithms reported in this paper enable D-39 data to be mapped into utilities predicted from any of six instruments. This provides choice for those conducting cost-utility analyses. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Geosciences research: development of techniques and instruments for investigation geological environments

    International Nuclear Information System (INIS)

    1993-01-01

    In order to understand the geological environment in Japan, new investigation techniques have been developed. These include: 1) Geological techniques for fracture characterization, 2) Nondestructive investigation techniques for detailed geological structure, 3) Instruments for hydraulic characterization, 4) Instruments for hydrochemical characterization. Results so far obtained are: 1) Fractures can be classified by their patterns, 2) The applicability and limitations of conventional geophysical methods were defined, 3) Instruments for measuring very low permeability were successfully developed, 4) Instruments for sampling formation water without changing in-situ conditions were developed. (author)

  12. USB technique and its application in nuclear instruments

    International Nuclear Information System (INIS)

    Zhou Tong; Wei Yixiang; Wang Yuemin

    2001-01-01

    This paper introduces the technique of communication of USB between computer and collection interface in nuclear instruments. Because Universal Serial Bus has many advantages such as high speed, low energy consuming and Plug and Play. It has been a universal interface of computer. The realization of communication by USB is a step to digital, modularization, and universality of instruments. The mainly content of this paper is the design of circuit and program of the USB intelligent interface, which include how to program a driver and how the software and the hardware interplay with each other. At the end, a testing result in a Multi-Channel Analyzer also is presented. This technique can also be used in other data acquisition instruments

  13. A Comparison of seismic instrument noise coherence analysis techniques

    Science.gov (United States)

    Ringler, A.T.; Hutt, C.R.; Evans, J.R.; Sandoval, L.D.

    2011-01-01

    The self-noise of a seismic instrument is a fundamental characteristic used to evaluate the quality of the instrument. It is important to be able to measure this self-noise robustly, to understand how differences among test configurations affect the tests, and to understand how different processing techniques and isolation methods (from nonseismic sources) can contribute to differences in results. We compare two popular coherence methods used for calculating incoherent noise, which is widely used as an estimate of instrument self-noise (incoherent noise and self-noise are not strictly identical but in observatory practice are approximately equivalent; Holcomb, 1989; Sleeman et al., 2006). Beyond directly comparing these two coherence methods on similar models of seismometers, we compare how small changes in test conditions can contribute to incoherent-noise estimates. These conditions include timing errors, signal-to-noise ratio changes (ratios between background noise and instrument incoherent noise), relative sensor locations, misalignment errors, processing techniques, and different configurations of sensor types.

  14. Premature Ejaculation and Utilization of Cognitive Techniques

    Directory of Open Access Journals (Sweden)

    Serkan AKKOYUNLU

    2013-03-01

    Full Text Available Introduction: Premature ejaculation is the most common male sexual dysfunction leading to distress in many couples. Master and Johnson emphasized the concept of early learned experiences and Kaplan emphasized lack of sensory awareness. For treatment sex therapists mainly utilize start-stop and squeeze techniques as homework. Couples enter sex therapy with some cognitive distortions and beliefs about sex and sexuality. These beliefs are also named sexual myths. For some couples using techniques to challenge cognitive distortions and maladaptive beliefs about sex and sexuality can be used. In this paper by presenting a case we discussed how cognitive techniques can be used along with behaviour techniques with couples. Case: Presenting clients are five years married couple who are thirty and twenty nine years old respectively. They attended to the outpatient clinic with the request of the female client. Their main complaint was premature ejaculation. They were diagnosed premature ejaculation using clinical interview. In treatment besides start and stop technique, cognitive techniques were utilized to address dysfunctional beliefs about sexuality. Discussion: Premature ejaculation is a male sexual dysfunction that causes distress and intimacy problems between couples. Stop start and squeeze techniques were accepted as the choice of treatment but their effectiveness is questioned recently. Also cognitive distortions and maladaptive beliefs may hamper therapy progress. Besides that, behavioral techniques utilizing cognitive techniques to lessen the degree of dysfunctional beliefs about sex and sexuality may help the couple to overcome premature ejaculation and enhance sexual satisfaction and intimacy.

  15. Innovative instrumentation for VVERs based in non-invasive techniques

    International Nuclear Information System (INIS)

    Jeanneau, H.; Favennec, J.M.; Tournu, E.; Germain, J.L.

    2000-01-01

    Nuclear power plants such as VVERs can greatly benefit from innovative instrumentation to improve plant safety and efficiency. In recent years innovative instrumentation has been developed for PWRs with the aim of providing additional measurements of physical parameters on the primary and secondary circuits: the addition of new instrumentation is made possible by using non-invasive techniques such as ultrasonics and radiation detection. These innovations can be adapted for upgrading VVERs presently in operation and also in future VVERs. The following innovative instrumentation for the control, monitoring or testing at VVERs is described: 1. instrumentation for more accurate primary side direct measurements (for a better monitoring of the primary circuit); 2. instrumentation to monitor radioactivity leaks (for a safer plant); 3. instrumentation-related systems to improve the plant efficiency (for a cheaper kWh)

  16. Field results of antifouling techniques for optical instruments

    Science.gov (United States)

    Strahle, W.J.; Hotchkiss, F.S.; Martini, Marinna A.

    1998-01-01

    An anti-fouling technique is developed for the protection of optical instruments from biofouling which leaches a bromide compound into a sample chamber and pumps new water into the chamber prior to measurement. The primary advantage of using bromide is that it is less toxic than the metal-based antifoulants. The drawback of the bromide technique is also discussed.

  17. Statistical evaluation of recorded knowledge in nuclear and other instrumental analytical techniques

    International Nuclear Information System (INIS)

    Braun, T.

    1987-01-01

    The main points addressed in this study are the following: Statistical distribution patterns of published literature on instrumental analytical techniques 1981-1984; structure of scientific literature and heuristics for identifying active specialities and emerging hot spot research areas in instrumental analytical techniques; growth and growth rates of the literature in some of the identified hot research areas; quality and quantity in instrumental analytical research output. (orig.)

  18. Instrumented techniques in tool - and object perspectives

    DEFF Research Database (Denmark)

    Andresen, Mette

    2007-01-01

    The aim of this paper is to report from a study of the role of instrumented techniques in the students? learning process. The paper analyses an episode from a case study of students solving differential equations in a CAS environment. The analysis demonstrates how tasks can be designed with the aim...... to encourage the students to change between the perspective of tool on a mathematical conception and the perspective of object on the conception. Reasons are given in the paper for the assertion, that changing between these two perspectives supports the instrumental genesis as well as the conceptual...

  19. Development of thermocouple re-instrumentation technique for irradiated fuel rod. Techniques for making center hole into UO2 pellets and thermocouple re-instrumentation to fuel rod

    International Nuclear Information System (INIS)

    Shimizu, Michio; Saito, Junichi; Oshima, Kunio

    1995-07-01

    The information on FP gas pressure and centerline temperature of fuel pellets during power transient is important to study the pellet clad interaction (PCI) mechanism of high burnup LWR fuel rods. At the Department of JMTR, a re-instrumentation technique of FP gas pressure gage for an irradiated fuel rod was developed in 1990. Furthermore, a thermocouple re-instrumentation technique was successfully developed in 1994. Two steps were taken to carry out the development program of the thermocouple re-instrumentation technique. In the first step, a drilling technique was developed for making a center hole of the irradiated fuel pellets. Various drilling tests were carried out using dummy of fuel rods consisted of Ba 2 FeO 3 pellets and Zry-2 cladding. On this work it is important to keep the pellets just the state cracked at a power reactor. In these tests, the technique to fix the pellets by frozen CO 2 was used during the drilling work. Also, diamond drills were used to make the center hole. These tests were completed successfully. A center hole, 54mm depth and 2.5mm diameter, was realized by these methods. The second step of this program is the in-pile demonstration test on an irradiated fuel rod instrumented dually a thermocouple and FP gas pressure gage. The demonstration test was carried out at the JMTR in 1995. (author)

  20. Intraosseous anesthesia: implications, instrumentation and techniques.

    Science.gov (United States)

    Kleber, Christopher H

    2003-04-01

    The author reviews historical methods and the instruments used to bring about intraosseous anesthesia, or IOA; discusses the criteria for successful use of the intraosseous injection, or IOI, technique; and provides recommendations. Articles from before 1990 consisted of subjective reports of patient types and procedures performed using IOI as a primary technique. Studies published after 1990 yielded subjective findings on indications for expanded clinical use. The author discusses the expansion of the role of IOI relative to integrated local anesthetic delivery systems. The literature and studies verify the efficacy of IOI as a supplemental or primary technique. The author recommends anesthetics and infusion sites, and reports on the patients' perceptions of comfort. IOI can be used as a supplemental or primary technique to bring about local anesthesia in routine dental procedures. It can be used as a supplemental technique with mandibular nerve blocks to enhance deep pulpal anesthesia. It can be used as a primary technique so that patients do not experience numb lips or tongues postoperatively. Dentists can appreciate the immediate onset of anesthesia and reduced dosage levels of anesthetics associated with using IOI.

  1. Advanced instrumentation and control techniques for nuclear power plants

    International Nuclear Information System (INIS)

    Hayakawa, Hiroyasu; Makino, Maomi

    1989-01-01

    Toshiba has been promoting the development and improvement of control and instrumentation (C and I) systems employing the latest technologies, to fulfill the requirements of nuclear power plants for increased reliability, the upgrading of functions, improved maintainability, and reasonable cost. Such development has been systematically performed based on a schematic view of integrated digital control and instrumentation systems, actively adopting state-of-the-art techniques such as the latest man-machine interfaces, digital and optical multiplexing techniques, and artificial intelligence. In addition, comprehensive feedback has been obtained from the accumulation of operating experience. This paper describes the purpose, contents and status of applications of representative newly-developed systems. (author)

  2. Measurement techniques and instruments suitable for life-prediction testing of photovoltaic arrays. Interim report

    Energy Technology Data Exchange (ETDEWEB)

    Noel, G.T.; Sliemers, F.A.; Deringer, G.C.; Wood, V.E.; Wilkes, K.E.; Gaines, G.B.; Carmichael, D.C.

    1978-01-15

    The validation of a service life of 20 years for low-cost photovoltaic arrays must be accomplished through accelerated life-prediction tests. A methodology for such tests has been developed in a preceding study. The results discussed consist of the initial identification and assessment of all known measurement techniques and instruments that might be used in these life-prediction tests. Array failure modes, relevant materials property changes, and primary degradation mechanisms are discussed as a prerequisite to identifying suitable measurement techniques and instruments. Candidate techniques and instruments are identified on the basis of extensive reviews of published and unpublished information. These methods are organized in six measurement categories--chemical, electrical, optical, thermal, mechanical, and ''other physicals''. Using specified evaluation criteria, the most promising techniques and instruments for use in life-prediction tests of arrays are then selected. These recommended techniques and their characteristics are described. Recommendations are made regarding establishment of the adequacy, particularly with respect to precision, of the more fully developed techniques for this application, and regarding the experimental evaluation of promising developmental techniques. Measurement needs not satisfied by presently available techniques/instruments are also identified.

  3. Novel Techniques for Background / Foreground Rejection in Particle Instruments

    Data.gov (United States)

    National Aeronautics and Space Administration — The Novel Techniques for Background / Foreground Rejection in Particle Instruments project addresses the need for signal contamination and background signal...

  4. Pre-concentration technique for reduction in "Analytical instrument requirement and analysis"

    Science.gov (United States)

    Pal, Sangita; Singha, Mousumi; Meena, Sher Singh

    2018-04-01

    Availability of analytical instruments for a methodical detection of known and unknown effluents imposes a serious hindrance in qualification and quantification. Several analytical instruments such as Elemental analyzer, ICP-MS, ICP-AES, EDXRF, ion chromatography, Electro-analytical instruments which are not only expensive but also time consuming, required maintenance, damaged essential parts replacement which are of serious concern. Move over for field study and instant detection installation of these instruments are not convenient to each and every place. Therefore, technique such as pre-concentration of metal ions especially for lean stream elaborated and justified. Chelation/sequestration is the key of immobilization technique which is simple, user friendly, most effective, least expensive, time efficient; easy to carry (10g - 20g vial) to experimental field/site has been demonstrated.

  5. Argonne National Laboratory's thermal plume measurements: instruments and techniques

    International Nuclear Information System (INIS)

    Van Loon, L.S.; Frigo, A.A.; Paddock, R.A.

    1977-12-01

    Instrumentation and techniques were developed at Argonne National Laboratory for measuring the three-dimensional temperature structure of thermal plumes from power plants, along with the limnological, meteorological, and plant operating conditions affecting their behavior. The equipment and procedures were designed to provide field data for use in evaluating predictive models that describe thermal plume behavior, and over 100 sets of these data have been collected. The instrument systems and techniques employed in a typical thermal discharge survey are highly integrated. Continuous monitoring of ambient and plant conditions is coupled with plume mapping from a moving survey boat. The instantaneous location of the boat together with subsurface temperature measurements from a towed thermistor chain provide a quasisynoptic view of the plume structure. Real-time, onboard display of the boat path and vertical temperatures supply feedback to investigators for determining the extent and spatial resolution of measurements required. The unique design, reliability, accuracy, calibration, and historical development of the components of these integrated systems are described. Survey system interfaces with data handling and processing techniques are also explained. Special supportive studies to investigate plume dynamics, values of eddy diffusivities, time-temperature histories of water parcels in thermal plumes, and rapid changes in plume shape are also described along with instrumentation used

  6. Study on Instrument Fault Detection using OLM Techniques for PHM Application in NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Hwan; Park, Gee Yong; Kim, Jung Taek; Hur, Seop [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    The diagnosis system is relatively being mature owing to many research. Among the various models, this paper introduces some On-Line Monitoring (OLM) models for instrument health monitoring and review applicability on NPPs. In recent years, many researchers are being focused on the prognostics which is predicting the future failure of instruments or equipment by using the status monitoring data. By using the prognostic techniques, we can expect a lot of advantages such as ease of control, power optimization, or optimal use of maintenance resources. And we have performed the test for detecting fault of safety-critical instruments and analyzed the fault detection sensitivity for various instrument failure modes using OLM techniques. OLM techniques using data-driven based model such AAKR or AANN can be useful tools for securing integrity of safety-critical instrument that should always keep healthy conditions for the plant safety.

  7. Support for cold neutron utilization

    International Nuclear Information System (INIS)

    Lee, Kye Hong; Han, Young Soo; Choi, Sungmin; Choi, Yong; Kwon, Hoon; Lee, Kwang Hee

    2012-06-01

    - Support for experiments by users of cold neutron scattering instrument - Short-term training of current and potential users of cold neutron scattering instrument for their effective use of the instrument - International collaboration for advanced utilization of cold neutron scattering instruments - Selection and training of qualified instrument scientists for vigorous research endeavors and outstanding achievements in experiments with cold neutron - Research on nano/bio materials using cold neutron scattering instruments - Bulk nano structure measurement using small angle neutron scattering and development of analysis technique

  8. Safety Assessment of Two Hybrid Instrumentation Techniques in a Dental Student Endodontic Clinic: A Retrospective Study.

    Science.gov (United States)

    Coelho, Marcelo Santos; Card, Steven John; Tawil, Peter Zahi

    2017-03-01

    The aim of this study was to retrospectively assess the safety potential of a hybrid technique combining nickel-titanium (NiTi) reciprocating and rotary instruments by third- and fourth-year dental students in the predoctoral endodontics clinic at one U.S. dental school. For the study, 3,194 root canal treatments performed by 317 dental students from 2012 through 2015 were evaluated for incidence of ledge creation and instrument separation. The hybrid reciprocating and rotary technique (RRT) consisted of a glide path creation with stainless steel hand files up to size 15/02, a crown down preparation with a NiTi reciprocating instrument, and an apical preparation with NiTi rotary instruments. The control was a traditional rotary and hand technique (RHT) that consisted of the same glide path procedure followed by a crown down preparation with NiTi rotary instruments and an apical preparation with NiTi hand instruments. The results showed that the RHT technique presented a rate of ledge creation of 1.4% per root and the RRT technique was 0.5% per root (protary technique for root canal instrumentation by these dental students provided good safety. This hybrid technique offered a low rate of ledge creation along with no NiTi instrument separation.

  9. Premature Ejaculation and Utilization of Cognitive Techniques

    Directory of Open Access Journals (Sweden)

    Serkan AKKOYUNLU

    2013-04-01

    Discussion: Premature ejaculation is a male sexual dysfunction that causes distress and intimacy problems between couples. Stop start and squeeze techniques were accepted as the choice of treatment but their effectiveness is questioned recently. Also cognitive distortions and maladaptive beliefs may hamper therapy progress. Besides that, behavioral techniques utilizing cognitive techniques to lessen the degree of dysfunctional beliefs about sex and sexuality may help the couple to overcome premature ejaculation and enhance sexual satisfaction and intimacy. [JCBPR 2013; 2(1.000: 47-52

  10. Utility of Military Strategy as an Instrument of Foreign Policy | Ebaye ...

    African Journals Online (AJOL)

    This research has taken a critical appraisal of state actors in the international system, and the utility of military power as an instrument of foreign policy. The paper asserts as Osgood did, that one of the main prerequisite of a credible state actor is to develop the military compatibilities and political will, to back its diplomacy by ...

  11. Instrumentation development

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    Areas being investigated for instrumentation improvement during low-level pollution monitoring include laser opto-acoustic spectroscopy, x-ray fluorescence spectroscopy, optical fluorescence spectroscopy, liquid crystal gas detectors, advanced forms of atomic absorption spectroscopy, electro-analytical chemistry, and mass spectroscopy. Emphasis is also directed toward development of physical methods, as opposed to conventional chemical analysis techniques for monitoring these trace amounts of pollution related to energy development and utilization

  12. The single chip microcomputer technique in an intelligent nuclear instrument

    International Nuclear Information System (INIS)

    Wang Tieliu; Sun Punan; Wang Ying

    1995-01-01

    The authors present that how to acquire and process the output signals from the nuclear detector adopting single chip microcomputer technique, including working principles and the designing method of the computer's software and hardware in the single chip microcomputer instrument

  13. Single event upset mitigation techniques for FPGAs utilized in nuclear power plant digital instrumentation and control

    International Nuclear Information System (INIS)

    Wang Xin; Holbert, Keith E.; Clark, Lawrence T.

    2011-01-01

    Highlights: → Triple modular redundancy (TMR) implementation is the best solution for digital I and C. → Maximal probability of two simultaneous errors with TMR maximum partition is 4.44%. → Dual modular redundancy minimum logic partitioning design is an additional option. - Abstract: Field programmable gate arrays (FPGAs) are integrated circuits being increasingly used for digital instrumentation and control (I and C) in nuclear power plants (NPPs) because of low cost, re-configurability and low design turn-around time. However, to ensure reliability, proper design techniques must be employed since the memory and logic in FPGAs are susceptible to single event upsets (SEUs). Triple modular redundancy (TMR) has become a common SEU mitigation design technique because of its straightforward implementation and reliable results. Partitioned TMR approaches are introduced in this paper, and formulae derived indicate that the maximum probability of two simultaneous errors [P E ] max is inversely proportional to the number of logic partitions in a TMR design, when each redundant logic block in every logic partition has the same number of sensitive nodes. However, the maximum logic partitioning design cannot completely eliminate the possibility of two simultaneous upsets. For the example test circuit it is found that [P E ] max is reduced dramatically from 66.67% for minimum logic partitioning to 4.44% for maximum logic partitioning. Because TMR introduces significant overhead due to its full hardware redundancy, a dual modular redundancy approach is also examined for application to less demanding situations. By comparative analysis this study reaches the conclusion that the maximum logic partitioning TMR implementation is the best solution for digital I and C applications in NPPs where obtaining robustness is of the highest importance, despite its higher area overhead.

  14. Contrast echocardiography: history, micro bubble characteristics and instrumental techniques

    International Nuclear Information System (INIS)

    Cubides, Carlos; Restrepo, Gustavo; Aristizabal, Dagnovar; Munera, Ana

    2006-01-01

    This article describes the history of contrast echocardiography, the physical characteristics of the contrast agent's micro bubbles, the main instrumental tools (mechanical index, focus and focusing, frame rate), and the echocardiography techniques (second harmonic imaging, fusion harmonic, power pulse inversion imaging, triggered imaging, intermittent harmonic power Doppler, color power angio and acoustic densitometry), actually available for clinical use

  15. A Checklist for Reporting Valuation Studies of Multi-Attribute Utility-Based Instruments (CREATE)

    NARCIS (Netherlands)

    Xie, Feng; Pickard, A. Simon; Krabbe, Paul F. M.; Revicki, Dennis; Viney, Rosalie; Devlin, Nancy; Feeny, David

    Multi-attribute utility-based instruments (MAUIs) assess health status and provide an index score on the full health-dead scale, and are widely used to support reimbursement decisions for new healthcare interventions worldwide. A valuation study is a key part of the development of MAUIs, with the

  16. Quantification of chlorine in zirconium oxide and biological samples by instrumental NAA utilizing PCF of Dhruva reactor

    International Nuclear Information System (INIS)

    Shinde, Amol D.; Reddy, A.V.R.; Acharya, R.; Balaji Rao, Y.

    2012-01-01

    Recently studies on chlorine contents in various samples are being pursued due to its corrosive nature. Chlorine present at trace level in various finished products as well as powder is used as a raw material for production of different types of zircaloys used as structural materials in nuclear technology. As a part of quality assurance program, it is necessary to quantify chlorine accurately with suitable and simple technique. In the present work we have applied instrumental neutron activation analysis (INAA) utilizing its short-lived activation product ( 38 Cl, 37 min, 1642 and 2168 keV) for its estimation. Pneumatic Carrier Facility (PCF) of Dhruva reactor, BARC was used sample irradiation of zirconium oxide dry powder, synthetic wax and IAEA RMs 1515 (Apple leaves) and Lichen 336. (author)

  17. MicroASC instrument onboard Juno spacecraft utilizing inertially controlled imaging

    DEFF Research Database (Denmark)

    Pedersen, David Arge Klevang; Jørgensen, Andreas Härstedt; Benn, Mathias

    2016-01-01

    This contribution describes the post-processing of the raw image data acquired by the microASC instrument during the Earth-fly-by of the Juno spacecraft. The images show a unique view of the Earth and Moon system as seen from afar. The procedure utilizes attitude measurements and inter......-calibration of the Camera Head Units of the microASC system to trigger the image capturing. The triggering is synchronized with the inertial attitude and rotational phase of the sensor acquiring the images. This is essentially works as inertially controlled imaging facilitating image acquisition from unexplored...

  18. Ultrasonic imaging with a fixed instrument configuration

    Energy Technology Data Exchange (ETDEWEB)

    Witten, A.; Tuggle, J.; Waag, R.C.

    1988-07-04

    Diffraction tomography is a technique based on an inversion of the wave equation which has been proposed for high-resolution ultrasonic imaging. While this approach has been considered for diagnostic medical applications, it has, until recently, been limited by practical limitations on the speed of data acquisition associated with instrument motions. This letter presents the results of an experimental study directed towards demonstrating tomography utilizing a fixed instrument configuration.

  19. Measurement and instrumentation techniques for monitoring plutonium and uranium particulates released from nuclear facilities

    International Nuclear Information System (INIS)

    Nero, A.V. Jr.

    1976-08-01

    The purpose of this work has been an analysis and evaluation of the state-of-the-art of measurement and instrumentation techniques for monitoring plutonium and uranium particulates released from nuclear facilities. The occurrence of plutonium and uranium in the nuclear fuel cycle, the corresponding potential for releases, associated radiological protection standards and monitoring objectives are discussed. Techniques for monitoring via decay radiation from plutonium and uranium isotopes are presented in detail, emphasizing air monitoring, but also including soil sampling and survey methods. Additionally, activation and mass measurement techniques are discussed. The availability and prevalence of these various techniques are summarized. Finally, possible improvements in monitoring capabilities due to alterations in instrumentation, data analysis, or programs are presented

  20. Improved biomass utilization through the use of nuclear techniques

    International Nuclear Information System (INIS)

    1988-10-01

    Biomass is a major by-product resource of agriculture and food manufacturing, but it is under-utilized as a source of food, fibre, and chemicals. Nuclear techniques provide unique tools for studies of the capabilities of micro-organisms in methane digestor operation and in the transformation of lignocellulosic materials to useful products. Nuclear techniques have also been effectively employed as mutagenic agents in the preparation of more efficient microbial strains for the conversion of biomass. This report reviews the variety and diversity of such applications with focus on the development of microbial processes to utilize agricultural wastes and by-products. The value of nuclear techniques is manifestly demonstrated in the production of efficient microbial mutant strains, in the tracing of metabolic pathways, in the monitoring of lignin degradation and also of fermenter operation. Refs, figs and tabs

  1. Safeguarding on-power fuelled reactors - instrumentation and techniques

    International Nuclear Information System (INIS)

    Waligura, A.; Konnov, Y.; Smith, R.M.; Head, D.A.

    1977-01-01

    Instrumentation and techniques applicable to safeguarding reactors that are fuelled on-power, particularly the CANDU type, have been developed. A demonstration is being carried out at the Douglas Point Nuclear Generating Station in Canada. Irradiated nuclear materials in certain areas - the reactor and spent fuel storage bays - are monitored using photographic and television cameras, and seals. Item accounting is applied by counting spent-fuel bundles during transfer from the reactor to the storage bay and by placing these spent-fuel bundles in a sealed enclosure. Provision is made for inspection and verification of the bundles before sealing. The reactor's power history is recorded by a track-etch power monitor. Redundancy is provided so that the failure of any single piece of equipment does not invalidate the entire safeguards system. Several safeguards instruments and devices have beeen developed and evaluated. These include a super-8 mm surveillance camera system, a television surveillance system, a spent-fuel bundle counter, a device to detect dummy fuel bundles, a cover for enclosing a stack of spent-fuel bundles, and a seal suitable for underwater installation and ultrasonic interrogation. The information provided by these different instruments should increase the effectiveness of Agency safeguards and, when used in combination with other measures, will facilitate inspection at reactor sites

  2. Recent advances in the instrumental techniques for the analysis of modern materials (II)

    International Nuclear Information System (INIS)

    Ahmed, M.

    1990-01-01

    Inductively Coupled Plasma Mass Spectrometry ICP-MS a logical development of equally established sister technique of ICP-AEA discussed in part-1 of this series of article on modern analytical techniques. The rapid adaptation of argon plasma as ion source for time of flight quadrupole mass analyser has led to the development of truly integrated instrumental technique for analysis of solutions and slurries. The powerful combination with laser ablation device has made the direct analysis of geological, geochemical and other complex conducting and non conducting samples possible in days rather months at sub ppm levels. Parallel development in computer hardware and software has made the instrumental optimization easy enabling the generation of meaningful analytical data a matter of routine. The limitations imposed by spectroscopic and non restricted the variety of matrices and materials covered by ICP-MS of LA-ICP-MS. The technique has provided it formidable analytical power in wide areas of industrial environmental, social, biological and break through advanced materials used in space mass communication, transportation and general areas of advanced analytical chemistry. It is expected that in combination with other instrumental methods as HPLC, ETC, ion chromatography. ICP-MS shall continue to dominate well into the 21st century. (author)

  3. Proceedings of the symposium on advanced measurement techniques and instrumentation: abstract book

    International Nuclear Information System (INIS)

    Kale, Y.B.; Kushwaha, M.; Somkuwar, S.P.; Ajayakumar, S.; Sampathkumar, R.

    2011-01-01

    In order to consolidate the existing knowledge base and further to focus on the future directions of the field of advanced measurement techniques and instrumentation, Bhabha Atomic Research Centre has organized a three-day symposium on 'Advanced Measurement Techniques and Instrumentation' at Multi Purpose Hall, Training School Hostel, Anushaktinagar, Mumbai during February 02-04, 2011. The symposium is aimed at providing a forum to discuss the emerging trends and challenges ahead in the important area of measurement science and technology. This is a unique symposium, which brings together scientists and engineers from all disciplines and provides them a platform for close interaction to exchange ideas, methodologies and expertise, which is extremely important for synergic growth of this field. The symposium consists of 27 talks, which include keynote address, plenary and invited talks, and 63 contributory papers. The abstracts of these papers are brought to you in this volume. Readers may observe that the scientific programme of the symposium covers a wide ranging issues including advanced scientific concepts in measurements, instrumentation strategies, mathematical techniques and development of devices for applications in fundamental physics, astrophysics, fusion plasmas, nuclear reactors, accelerators, environment, chemical and biological sciences, and national security. Papers relevant to INIS are indexed separately

  4. Utilization of the Differential Die-Away Self-Interrogation Technique for Characterization and Verification of Spent Nuclear Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Trahan, Alexis Chanel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-01-27

    New nondestructive assay techniques are sought to better characterize spent nuclear fuel. One of the NDA instruments selected for possible deployment is differential die-away self-interrogation (DDSI). The proposed DDSI approach for spent fuel assembly assay utilizes primarily the spontaneous fission and (α, n) neutrons in the assemblies as an internal interrogating radiation source. The neutrons released in spontaneous fission or (α,n) reactions are thermalized in the surrounding water and induce fission in fissile isotopes, thereby creating a measurable signal from isotopes of interest that would be otherwise difficult to measure. The DDSI instrument employs neutron coincidence counting with 3He tubes and list-mode-based data acquisition to allow for production of Rossi-alpha distributions (RADs) in post-processing. The list-mode approach to data collection and subsequent construction of RADs has expanded the analytical possibilities, as will be demonstrated throughout this thesis. One of the primary advantages is that the measured signal in the form of a RAD can be analyzed in its entirety including determination of die-away times in different time domains. This capability led to the development of the early die-away method, a novel leakage multiplication determination method which is tested throughout the thesis on different sources in simulation space and fresh fuel experiments. The early die-away method is a robust, accurate, improved method of determining multiplication without the need for knowledge of the (α,n) source term. The DDSI technique and instrument are presented along with the many novel capabilities enabled by and discovered through RAD analysis. Among the new capabilities presented are the early die-away method, total plutonium content determination, and highly sensitive missing pin detection. Simulation of hundreds of different spent and fresh fuel assemblies were used to develop the analysis algorithms and the techniques were tested on a

  5. Recently-developed neutron activation analysis techniques utilizing the University of California at Irvine TRIGA Mark I reactor

    International Nuclear Information System (INIS)

    Guinn, V.P.; Chambless, D.; Cortes T, E.; DeLancey, K.; Garzonov, E.; Miller, D.A.; Miller, G.E.; Purcell, M.A.

    1976-01-01

    The University of California at Irvine (UCI) 250 kW TRIGA Mark I reactor is used extensively for neutron activation analysis (NAA) studies. These particularly include basic technique studies and application studies in the fields of environmental pollution, crime investigation, archaeology, oceanography, and geochemistry. In recent NAA studies at UCI, a number of techniques have been developed which considerably improve the usefulness of such a research reactor for NAA work, and which should be of interest and use to others. Six of these techniques will be described in further detail in the full paper. They are as follows: development and use of (1) an automated high-precision rapid transfer system for instrumental NAA measurements with induced activities having half lives as short as 0.5 second, (2) an automated measurement system and computer program for making accurate dead-time corrections under conditions where the Ge(Li) spectrometer deadtime is changing rapidly during the counting period, (3) a technique to minimize the loss of mercury from samples during reactor irradiation via the use of dry-ice-packed, vented TRIGA rotary rack tubes, (4) a technique for compacting powdered samples, by pre-irradiation treatment with a solution of paraffin in carbon disulfide, to provide reproducible irradiation and counting geometries, (5) a method utilizing hydrated antimony pentoxide (HAP) as a pre-irradiation treatment material for removal of sodium from aqueous and wet-ashed samples, and (6) a computerized system for predicting in advance of activation, from approximate known elemental compositions, the total counting rate, deadtime, spectrum shape, principal photopeaks, and approximate actual lower limits of instrumental NAA detection of designated elements for any selected irradiation and decay times. (author)

  6. A Survey on Nickel Titanium Rotary Instruments and their Usage Techniques by Endodontists in India.

    Science.gov (United States)

    Patil, Thimmanagowda N; Saraf, Prahlad A; Penukonda, Raghavendra; Vanaki, Sneha S; Kamatagi, Laxmikant

    2017-05-01

    The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited information is available to explain the adoption of changing concepts with respect to nickel titanium rotary instruments pertaining to the endodontists in India. The aim of this study was to conduct a questionnaire survey to acquire the knowledge concerning different NiTi rotary instruments and their usage techniques by endodontists in India. A Survey questionnaire was designed which consisted of 32 questions regarding designation, demographics, experience with rotary instruments, usage of different file systems, usage techniques, frequency of reuse, occurrence of file fracture, reasons and their management was distributed by hand in the national postgraduate convention and also disseminated via electronic medium to 400 and 600 endodontists respectively. Information was collected from each individual to gain insight into the experiences and beliefs of endodontists concerning the new endodontic technology of rotary NiTi instrumentation based on their clinical experience with the rotary systems. The questions were designed to ascertain the problems, patterns of use and to identify areas of perceived or potential concern regarding the rotary instruments and the data acquired was statistically evaluated using Fisher's-exact test and the Chi-Square test. Overall 63.8% (638) endodontists responded. ProTaper was one of the most commonly used file system followed by M two and ProTaper Next. There was a significant co relation between the years of experience and the file re use frequency, preparation technique, file separation, management of file separation. A large number of Endodontists prefer to reuse the rotary NiTi instruments. As there was an increase in the experience, the incidence of file separation reduced with increasing number of re use frequency and with

  7. Further development of the instrument and technique for photometric evaluation of autoradiograms

    Energy Technology Data Exchange (ETDEWEB)

    Freyer, K; Baumbach, H; Birkholz, W; Kiese, H J [Akademie der Wissenschaften der DDR, Leipzig. Zentralinstitut fuer Isotopen- und Strahlenforschung

    1976-01-01

    Analogous and digital techniques for evaluation of autoradiograms are compared and measured for critical evaluation of autoradiograms. Additional instruments to a Zeiss-Photometer for digital and analogous evaluation of autoradiograms are described.

  8. Tabular cross section file generation and utilization techniques

    International Nuclear Information System (INIS)

    Cullen, D.E.; Ozer, O.; Weisbin, C.R.

    1975-03-01

    Criteria of importance to the generation of linear cross section tabulations are presented. Algorithms for reducing or thinning such tables within a desired accuracy criterion and the implementation of paging techniques for efficient utilization of large data tables are reviewed. (1 figure, 3 tables) (U.S.)

  9. Neutron flux measurement utilizing Campbell technique

    International Nuclear Information System (INIS)

    Kropik, M.

    2000-01-01

    Application of the Campbell technique for the neutron flux measurement is described in the contribution. This technique utilizes the AC component (noise) of a neutron chamber signal rather than a usually used DC component. The Campbell theorem, originally discovered to describe noise behaviour of valves, explains that the root mean square of the AC component of the chamber signal is proportional to the neutron flux (reactor power). The quadratic dependence of the reactor power on the root mean square value usually permits to accomplish the whole current power range of the neutron flux measurement by only one channel. Further advantage of the Campbell technique is that large pulses of the response to neutrons are favoured over small pulses of the response to gamma rays in the ratio of their mean square charge transfer and thus, the Campbell technique provides an excellent gamma rays discrimination in the current operational range of a neutron chamber. The neutron flux measurement channel using state of the art components was designed and put into operation. Its linearity, accuracy, dynamic range, time response and gamma discrimination were tested on the VR-1 nuclear reactor in Prague, and behaviour under high neutron flux (accident conditions) was tested on the TRIGA nuclear reactor in Vienna. (author)

  10. OECD/CSNI specialist meeting on advanced instrumentation and measurements techniques: summary and conclusions

    International Nuclear Information System (INIS)

    1997-01-01

    This specialist meeting on Advanced Instrumentation and Measurements Techniques was held in Santa Barbara (USA) in 1997 and attracted some 70 participants in ten technical sessions and a session of the round table discussions, with a total of 41 papers. It was intended to bring together the international experts in multi-phase flow instrumentation, experiment and modeling to review the state-of-the-art of the two-phase flow instrumentation methods and to discuss the relation between modeling needs and instrumentation capabilities. The following topics were included: Modeling needs and future direction for improved constitutive relations, interfacial area transport equation, and multi-dimensional two-fluid model formulation; local instrumentation developments for void fraction, interfacial area, phase velocities, turbulence, entrainment, particle size, thermal non-equilibrium, shear stress, nucleation, condensation and boiling; global instrumentation developments for void fraction, mass flow, two-phase level, non-condensable concentration, flow regimes, low flow and break flow; relation between modeling needs and instrumentation capabilities, future directions for experiments focused on modeling needs and for instrumentation developments

  11. Comparison of the Effect of Canal Preparation by Step Back Technique Using Hand Instruments and Gates Glidden Drills with ProTaper Universal Rotary System on the Root Resistance to Vertical Fracture

    Directory of Open Access Journals (Sweden)

    A Abbaszadegan

    2013-06-01

    Full Text Available Introduction: Cleaning and shaping of the root canal system with an efficient and safe technique are the major goals of root canal treatment. The aim of this study was to compare the conventional root canal preparation technique by hand instruments and Gates Glidden drills with ProTaper Universal Rotary system on the root susceptibility to vertical fracture. Methods: Thirty extracted human mandibular premolars were randomly assigned to two groups. In group I, apical preparation was performed with k-files up to #40 utilizing step back technique and coronal flaring was done with Gates Glidden drills. In group II, ProTaper Universal Rotary instruments were used up to the file F4. All teeth were obturated with lateral compaction technique using gutta-percha and AH26 sealer. A simulated periodontal ligament was fabricated, and the teeth were mounted. A stainless steel finger spreader #35 was mounted in an Instron testing machine and the necessary load to cause a root fracture was inserted and recorded. The obtained data were analyzed statistically using T-test. Results: The force required to fracture was significantly lower for the roots prepared by ProTaper instruments in comparison with the specimens prepared by hand instruments and Gates Glidden drills (P< 0.001. Conclusion: Canal preparation with ProTaper rotary instruments can make the roots more susceptible to vertical fracture than traditional instrumentation with k-files and Gates Glidden drills.

  12. The utilization of performance evaluation instruments by technical trainers to evaluate maintenance personnel in the nuclear power industry in the United States

    International Nuclear Information System (INIS)

    Hornberger, C.K.

    1993-01-01

    The purpose of this study was to document the utilization of performance evaluation instruments by technical trainers in the evaluation of maintenance personnel in US nuclear power plants. Performance evaluation of maintenance personnel has been identified by nuclear utilities and the Nuclear Regulatory Commission as the only acceptable method of determining worker competence. The NRC requires performance evaluation to be conducted to performance standards, but it does not specify the standards or the method to be utilized. Each plant is free to establish its own standards and methods of evaluation. This was a descriptive study utilizing descriptive statistics for the analysis of the data. The subjects included 655 maintenance trainers in 72 US nuclear plants. Conclusions of the study include: (1) Technical trainers are in compliance with NRC regulations. (2) Evaluation materials developed by the Institute of Nuclear Power Operations are used by technical trainers in every one of the 62 plants that responded. (3) In-plant or self-developed Performance Evaluation Instruments are utilized by 419 or 95.2% of the technical trainers. (4) Technical trainers incorporate nine common components into their Performance Evaluation Instruments. (5) Technical trainers evaluate maintenance processes and the product produced by workers when following procedures and specifications are critical and when safety hazards are involved. (6) Technical trainers believe that utilizing Performance Evaluation Instruments makes their job easier by providing documentation about the quality and standards of maintenance skills. (7) Technical trainers believe that maintenance workers benefit when their skills are assessed through the use of Performance Evaluation Instruments

  13. Evaluation of instruments used in particle size analysis by using the sedimentation technique

    International Nuclear Information System (INIS)

    Elmasry, M.A.A.; Abdrahman, A.A.M.; Ahmed, A.Z.

    2007-01-01

    This study is carried out to evaluate the performance of some instruments in which the sedimentation technique is used for the determination of particle size distribution using Stoke's law. A mathematical formula has been developed to calculate the particle size distribution for different cases and the results were compared to the real ones. The results revealed unsatisfactory agreement between the calculated and the measured values. In addition, illogic results were obtained indicating that the instruments in which the sedimentation technique is used are not the proper ones to provide accurate measurements except for mono particle size cases. More above, the results obtained represent the sedimentation rate but not the particle size distribution.

  14. Cleaning capacity of hybrid instrumentation technique using reamer with alternating cutting edges system files: Histological analysis

    Directory of Open Access Journals (Sweden)

    Emilio Carlos Sponchiado Junior

    2014-01-01

    Full Text Available Aim: The aim of the following study is to evaluate the cleaning capacity of a hybrid instrumentation technique using Reamer with Alternating Cutting Edges (RaCe system files in the apical third of mesial roots of mandibular molars. Materials and Methods: Twenty teeth were selected and separated into two groups (n = 20 according to instrumentation technique as follows: BioRaCe - chemomechanical preparation with K-type files #10 and #15; and files BioRaCe BR0, BR1, BR2, BR3, and BR4; HybTec - hybrid instrumentation technique with K-type files #10 and #15 in the working length, #20 at 2 mm, #25 at 3 mm, cervical preparation with Largo burs #1 and #2; apical preparation with K-type files #15, #20, and #25 and RaCe files #25.04 and #30.04. The root canals were irrigated with 1 ml of 2.5% sodium hypochlorite at each change of instrument. The specimens were histologically processed and photographed under light optical microscope. The images were inserted onto an integration grid to count the amount of debris present in the root canal. Results: BioRaCe presented the highest percentage of debris in the apical third, however, with no statistically significant difference for HybTec (P > 0.05. Conclusions: The hybrid technique presented similar cleaning capacity as the technique recommended by the manufacturer.

  15. Innovative operating modes and techniques for the spaceborne imaging radar-C instrument

    Science.gov (United States)

    Huneycutt, Bryan L.

    1990-01-01

    The operation of the spaceborne imaging radar-C (SIR-C) is discussed. The SIR-C instrument has been designed to obtain simultaneous multifrequency and simultaneous multipolarization radar images from a low earth orbit. It is a multiparameter imaging radar which will be flown during at least two different seasons. The instrument has been designed to operate in innovative modes such as the squint alignment mode, the extended aperture mode, the scansar mode, and the interferometry mode. The instrument has been designed to demonstrate innovative engineering techniques such as beam nulling for echo tracking, pulse-repetition frquency hopping for Doppler centroid tracking, generating the frequency step chirp for radar parameter flexibility, block floating point quantizing for data rate compression, and elevation beamwidth broadening for increasing the swath illumination.

  16. Apical extrusion of intracanal debris using two engine driven and step-back instrumentation techniques: an in-vitro study.

    Science.gov (United States)

    Kustarci, Alper; Akdemir, Neslihan; Siso, Seyda Herguner; Altunbas, Demet

    2008-10-01

    The purpose of this study was to compare in-vitro the amount of debris extruded apically from extracted teeth, using K3, Protaper rotary instruments and manual step-back technique. Forty five human single-rooted mandibular premolar teeth were randomly divided into 3 groups. The teeth in 3 groups were instrumented until reaching the working length with K3, Protaper rotary instruments and K-type stainless steel instruments with manual step-back technique, respectively. Debris extruded from the apical foramen was collected into centrifuge tubes and the amount was determined. The data obtained were analyzed using Kruskal-Wallis one-way analysis of variance and Mann-Whitney U tests, with P=.05 as the level for statistical significance. Statistically significant difference was observed between K3, Protaper and step-back groups in terms of debris extrusion (PStep-back group had the highest mean debris weight, which was significantly different from the K3 and Protaper groups (Pengine-driven Ni-Ti systems extruded significantly less apical debris than step-back technique. However, Protaper rotary instruments extruded significantly more debris than K3 rotary instruments.

  17. Safeguarding on-power fuelled reactors - instrumentation and techniques

    International Nuclear Information System (INIS)

    Waligura, A.; Konnov, Y.; Smith, R.M.; Head, D.A.

    1977-05-01

    Instrumentation and techniques applicable to safeguarding reactors that are fuelled on-power, particularly the CANDU type, have been developed. A demonstration is being carried out at the Douglas Point Nuclear Generating Station in Canada. Irradiated nuclear materials in certain areas - the reactor and spent fuel storage bays - are monitored using photographic and television cameras, and seals. Item accounting is applied by counting spent-fuel bundles during transfer from the reactor to the storage bay and by placing these spent-fuel bundles in a sealed enclosure. Provision is made for inspection and verification of the bundles before sealing. The reactor's power history is recorded by a Track-Etch power monitor. Redundancy is provided so that the failure of any single piece of equipment does not invalidate the entire safeguards system. Several safeguards instruments and devices have been developed and evaluated. These include a super-8-mm surveillance camera system, a television surveillance system, a spent-fuel bundle counter, a device to detect dummy fuel bundles, a cover for enclosing a stack of spent-fuel bundles, and a seal suitable for underwater installation and ultrasonic interrogation. (author)

  18. Robotic right middle lobectomy with a subxiphoid utility port.

    Science.gov (United States)

    Jayakumar, Shruti; Nardini, Marco; Papoulidis, Pavlos; Dunning, Joel

    2018-06-01

    We present the case of a 74-year-old man with Stage IIa pulmonary adenocarcinoma, for which he underwent a robotic right middle lobectomy. A 4-armed, 5-port approach was used. Four intercostal ports were created above the ninth rib using the Cerfolio's technique. The subxiphoid port was created in the midline, 5 cm down from the xiphisternum. The robot offers higher image quality, depth perception and improved articulation of the instruments, allowing for more accurate dissection and stitching. The usage of a subxiphoid utility port reduces the clashing between instruments, offers a good angle for stapling and provides a direct view of the instruments entering into the chest. Specimen removal through the subxiphoid port may reduce postoperative pain and enhance patient recovery. The use of the subxiphoid approach as a utility port for robotic surgery is promising and may be a suitable replacement for the traditional utility port.

  19. Instrumentation and process control development for in situ coal gasification. Fourth quarterly report, September--November 1975

    Energy Technology Data Exchange (ETDEWEB)

    Northrop, D.A. (ed.)

    1976-01-01

    The instrumentation effort for Phases 2 and 3 of the Second Hanna In Situ Coal Gasification Experiment was fielded and background data obtained prior to the initiation of Phase 2 on November 25, 1975. A total of over 600 channels of instrumentation in 15 instrumentation wells and two surface arrays was fielded for the instrumentation techniques under evaluation. The feasibility of the passive acoustic technique to locate the source of process-related noises has been demonstrated; its utility is presently hampered by the inexact definition of signal arrivals and the lack of automated signal monitoring and analysis systems. A revised mathematical model for the electrical techniques has been developed which demonstrates the potential for remote monitoring. (auth)

  20. Construction of the descriptive system for the Assessment of Quality of Life AQoL-6D utility instrument.

    Science.gov (United States)

    Richardson, Jeffrey R J; Peacock, Stuart J; Hawthorne, Graeme; Iezzi, Angelo; Elsworth, Gerald; Day, Neil A

    2012-04-17

    Multi attribute utility (MAU) instruments are used to include the health related quality of life (HRQoL) in economic evaluations of health programs. Comparative studies suggest different MAU instruments measure related but different constructs. The objective of this paper is to describe the methods employed to achieve content validity in the descriptive system of the Assessment of Quality of Life (AQoL)-6D, MAU instrument. The AQoL program introduced the use of psychometric methods in the construction of health related MAU instruments. To develop the AQoL-6D we selected 112 items from previous research, focus groups and expert judgment and administered them to 316 members of the public and 302 hospital patients. The search for content validity across a broad spectrum of health states required both formative and reflective modelling. We employed Exploratory Factor Analysis and Structural Equation Modelling (SEM) to meet these dual requirements. The resulting instrument employs 20 items in a multi-tier descriptive system. Latent dimension variables achieve sensitive descriptions of 6 dimensions which, in turn, combine to form a single latent QoL variable. Diagnostic statistics from the SEM analysis are exceptionally good and confirm the hypothesised structure of the model. The AQoL-6D descriptive system has good psychometric properties. They imply that the instrument has achieved construct validity and provides a sensitive description of HRQoL. This means that it may be used with confidence for measuring health related quality of life and that it is a suitable basis for modelling utilities for inclusion in the economic evaluation of health programs.

  1. Technique for increasing dynamic range of space-borne ion composition instruments

    International Nuclear Information System (INIS)

    Burch, J.L.; Miller, G.P.; Santos, A. de los; Pollock, C.J.; Pope, S.E.; Valek, P. W.; Young, D.T.

    2005-01-01

    The dynamic range of ion composition spectrometers is limited by several factors, including saturation of particle counters and spillover of signals from highly dominant species into channels tuned to minor species. Instruments designed for composition measurements of hot plasmas in space can suffer greatly from both of these problems because of the wide energy range required and the wide disparity in fluxes encountered in various regions of interest. In order to detect minor ions in regions of very weak fluxes, geometry factors need to be as large as possible within the mass and volume resources available. As a result, problems with saturation by the dominant fluxes and spillover to minor-ion channels in plasma regions with intense fluxes become especially acute. This article reports on a technique for solving the dynamic-range problem in the few eV to several keV energy/charge range that is of central importance for space physics research where the dominant ion is of low mass/charge (typically H + ), and the minor ions are of higher mass/charge (typically O + ). The technique involves employing a radio-frequency modulation of the deflection electric field in the back section of an electrostatic analyzer in a time-of-flight instrument. This technique is shown to reduce H + counts by a controllable amount of up to factors of 1000 while reducing O + counts by only a few percent that can be calibrated

  2. Use of neural network techniques to identify cosmic ray electrons and positrons during the 1993 balloon flight of the NMSU/Wizard-TS93 instrument

    Energy Technology Data Exchange (ETDEWEB)

    Bellotti, R.; Castellano, M. [Bari Univ. (Italy)]|[INFN, Bari (Italy); Candusso, M.; Casolino, M.; Morselli, A.; Picozza, P. [Rome Univ. `Tor Vergata` (Italy)]|[INFN, Rome (Italy); Aversa, F.; Boezio, M. [Trieste Univ. (Italy)]|[INFN, Trieste (Italy); Barbiellini, G. [Trieste Univ. (Italy)]|[INFN, Trieste (Italy); Basini, G. [INFN, Laboratori Nazionali di Frascati, Rome (Italy)

    1995-09-01

    The detectors used in the TS93 balloon flight produced a large volume of information for each cosmic ray trigger. Some of the data was visual in nature, other portions contained energy deposition and timing information. The data sets are amenable to conventional analysis techniques but there is no assurance that conventional techniques make full use of subtle correlations and relations amongst the detector responses. With the advent of neural network technologies, particularly adept at classification of complex phenomena, it would seem appropriate to explore the utility of neural network techniques to classify particles observed with the instruments. In this paper neural network based methodology for signal/background discrimination in a cosmic ray space experiment is discussed. Results are presented for electron and positron classification in the TS93 flight data set and will be compared to conventional analyses.

  3. Proceedings: Instrumentation and control test reduction workshop

    International Nuclear Information System (INIS)

    1991-09-01

    Instrumentation and control (I ampersand C) surveillance and testing is a significant contributor to operations and management costs. Several techniques to eliminate or reduce manual testing requirements could reduce costs while improving plant safety and performance. I ampersand C test reduction was the subject of this 1991 workshop. The workshop covered test elimination, test reduction, test automation, and relevant standards and benefits. The conclusions of the workshop were the following: More utility information sharing is important. There is a significant amount of information available throughout the industry, but it is not available in a concise, useable form. An I ampersand C utility users group is needed to address items such as instrument calibration reduction, set-point methodologies, and other current I ampersand C issues. The workshop was well received. The timing is right to initiate actions to reduce testing

  4. Re-irradiation tests of spent fuel at JMTR by means of re-instrumentation technique

    International Nuclear Information System (INIS)

    Nakamura, Jinichi; Shimizu, Michio; Endo, Yasuichi; Nabeya, Hideaki; Ichise, Kenichi; Saito, Junichi; Oshima, Kunio; Uetsuka, Hiroshi

    1999-01-01

    JAERI has developed re-irradiation test procedures of spent fuel irradiated at commercial reactor by means of re-instrumentation technique. Full length rods irradiated at commercial LWRs were re-fabricated to short length rods, and rod inner pressure gauges and fuel center thermocouples were re-instrumented to the rods. Re-irradiation tests to study the fuel behavior during power change were carried out by means of BOCA/OSF-1 facility at the JMTR. In the tests to study the fission gas release during power change, the rod inner pressure increase was observed during power change, especially during power reduction. The fission gas release during power reduction is estimated to be the release from fission gas bubbles on the grain boundary caused by the thermal stress in the pellet during power reduction. Re-irradiation test of gadolinia added fuel was performed by means of dual re-instrumentation technique (fuel center thermocouples and rod inner pressure gauge). A stepwise fission gas release during power change, and the following fuel center temperature change due to gap conductance change were observed. (author)

  5. Micrometeorological Technique for Monitoring of Geological Carbon Capture, Utilization and Storage: Methodology, Workflow and Resources

    Science.gov (United States)

    Burba, G. G.; Madsen, R.; Feese, K.

    2013-12-01

    The eddy covariance (EC) method is a micrometeorological technique for direct high-speed measurements of the transport of gases and energy between land or water surfaces and the atmosphere [1]. This method allows for observations of gas transport scales from 20-40 times per second to multiple years, represents gas exchange integrated over a large area, from hundreds of square meters to tens of square kilometres, and corresponds to gas exchange from the entire surface, including canopy, and soil or water layers. Gas fluxes, emission and exchange rates are characterized from single-point in situ measurements using permanent or mobile towers, or moving platforms such as automobiles, helicopters, airplanes, etc. Presently, over 600 eddy covariance stations are in operation in over 120 countries [1]. EC is now recognized as an effective method in regulatory and industrial applications, including CCUS [2-10]. Emerging projects utilize EC to continuously monitor large areas before and after the injections, to locate and quantify leakages where CO2 may escape from the subsurface, to improve storage efficiency, and for other CCUS characterizations [5-10]. Although EC is one of the most direct and defensible micrometeorological techniques measuring gas emission and transport, and complete automated stations and processing are readily available, the method is mathematically complex, and requires careful setup and execution specific to the site and project. With this in mind, step-by-step instructions were created in [1] to introduce a novice to the EC method, and to assist in further understanding of the method through more advanced references. In this presentation we provide brief highlights of the eddy covariance method, its application to geological carbon capture, utilization and storage, key requirements, instrumentation and software, and review educational resources particularly useful for carbon sequestration research. References: [1] Burba G. Eddy Covariance Method

  6. Construction of the descriptive system for the assessment of quality of life AQoL-6D utility instrument

    Directory of Open Access Journals (Sweden)

    Richardson Jeffrey RJ

    2012-04-01

    Full Text Available Abstract Background Multi attribute utility (MAU instruments are used to include the health related quality of life (HRQoL in economic evaluations of health programs. Comparative studies suggest different MAU instruments measure related but different constructs. The objective of this paper is to describe the methods employed to achieve content validity in the descriptive system of the Assessment of Quality of Life (AQoL-6D, MAU instrument. Methods The AQoL program introduced the use of psychometric methods in the construction of health related MAU instruments. To develop the AQoL-6D we selected 112 items from previous research, focus groups and expert judgment and administered them to 316 members of the public and 302 hospital patients. The search for content validity across a broad spectrum of health states required both formative and reflective modelling. We employed Exploratory Factor Analysis and Structural Equation Modelling (SEM to meet these dual requirements. Results and Discussion The resulting instrument employs 20 items in a multi-tier descriptive system. Latent dimension variables achieve sensitive descriptions of 6 dimensions which, in turn, combine to form a single latent QoL variable. Diagnostic statistics from the SEM analysis are exceptionally good and confirm the hypothesised structure of the model. Conclusions The AQoL-6D descriptive system has good psychometric properties. They imply that the instrument has achieved construct validity and provides a sensitive description of HRQoL. This means that it may be used with confidence for measuring health related quality of life and that it is a suitable basis for modelling utilities for inclusion in the economic evaluation of health programs.

  7. Buried pipeline leak-detection technique and instruments using radioactive tracers

    International Nuclear Information System (INIS)

    Zhou Shuxuan; Lu Qingqian; Tang Yonghua

    1987-01-01

    For detecting and locating leaks on buried pipelines, a leak-detection technique and related instruments have been developed. Some quantity of fluid mixed with a radioactive tracer is injected. After the pipeline is cleaned, a leak-detector is put into and moves along the pipline to monitor the leaked radioactivity and to record both the radioactive signal and the time signal on a magnetic tape. From the signal curves, it can be judged whether there are any leaks on the pipeline and, if any, where they are

  8. Derivation of tensile flow characteristics for austenitic materials from instrumented indentation technique

    International Nuclear Information System (INIS)

    Lee, K-W; Kim, K-H; Kim, J-Y; Kwon, D

    2008-01-01

    In this study, a method for deriving the tensile flow characteristics of austenitic materials from an instrumented indentation technique is presented along with its experimental verification. We proposed a modified algorithm for austenitic materials that takes their hardening behaviour into account. First, the true strain based on sine function instead of tangent function was adapted. It was proved that the sine function shows constant degrees of hardening which is a main characteristic of the hardening of austenitic materials. Second, a simple and linear constitutive equation was newly suggested to optimize indentation flow curves. The modified approach was experimentally verified by comparing tensile properties of five austenitic materials from uniaxial tensile test and instrumented indentation tests

  9. Application of Resource Utilization in Dementia (RUD) instrument in a global setting.

    Science.gov (United States)

    Wimo, Anders; Gustavsson, Anders; Jönsson, Linus; Winblad, Bengt; Hsu, Ming-Ann; Gannon, Brenda

    2013-07-01

    The Resource Utilization in Dementia (RUD) questionnaire is the most widely used instrument for resource use data collection in dementia, enabling comparison of costs of care across countries with differing health care provisions. Recent feedback from payers questioned its face validity given that health care provisions have changed since the initial development of the RUD in 1998. The aim of this study was to update the RUD to improve its face validity in Alzheimer's disease (AD) clinical research and its utility for health care resource allocation. An extensive PubMed review was conducted of current relevant resource items in AD in 15 countries. The findings were complemented by interviews with local care providers and experts in dementia care and health economics. Their proposed revisions were discussed with five leading dementia experts in North and South America, northern and southern Europe, and Asia. A new version of the RUD was developed based on their recommendations. RUD users identified a need for more information relevant to coverage decisions. Proposed revisions included changes to existing questions (e.g., to capture more accurately the number and type of health care visits) and the addition of new questions (e.g., on informal caregiver hours and the primary caregiver's hours of sleep). Several minor changes were made to the RUD instrument to improve the accuracy and precision of the data while maintaining comparability with the original version and reflecting current medical practice. The RUD Complete Version 4.0 is now available for use in future AD clinical trials. Copyright © 2013 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  10. Design and operation of dust measuring instrumentation based on the beta-radiation method

    International Nuclear Information System (INIS)

    Lilienfeld, P.

    1975-01-01

    The theory, instrument design aspects and applications of beta-radiation attenuation for the measurement of the mass concentration of airborne particulates are reviewed. Applicable methods of particle collection, beta sensing configurations, source ( 63 Ni, 14 C, 147 Pr, 85 Kr) and detector design criteria, electronic signal processing, digital control and instrument programming techniques are treated. Advantages, limitations and error sources of beta-attenuation instrumentation are analyzed. Applications to industrial dust measurements, source testing, ambient monitoring, and particle size analysis are the major areas of practical utilization of this technique, and its inherent capability for automated and unattended operation provides compatibility with process control synchronization and alarm, telemetry, and incorporation into pollution monitoring network sensing stations. (orig.) [de

  11. A comparison of three rotary systems and hand instrumentation technique for the elimination of Enterococcus faecalis from the root canal.

    Science.gov (United States)

    Gorduysus, Melahat; Nagas, Emre; Torun, Ozgur Yildirim; Gorduysus, Omer

    2011-12-01

    The aim of this study was to compare the in vitro reduction of a bacterial population in a root canal by mechanical instrumentation using three rotary systems and hand instrumentation technique. The root canals contaminated with a suspension of Enterococcus faecalis were instrumented using ProTaper, K3, HeroShaper and K-file hand instrumentation technique. Later the root canals were sampled. After serial dilutions, samples were incubated in culture media for 24 h. Bacterial colonies were counted and the results were given as number of colony-forming units per millilitre. The results showed that all the canal instrumentation systems reduced the number of bacterial cells in the root canals. Statistically, ProTaper instruments were more effective in reducing the number of bacteria than the other rotary files or hand instruments. © 2010 The Authors. Australian Endodontic Journal © 2010 Australian Society of Endodontology.

  12. Analysis of instrumentation technology for SMART

    International Nuclear Information System (INIS)

    Hur, Seop; Koo, I. S.; Park, H. Y.; Lee, C. K.; Kim, D. H.; Suh, Y. S.; Seong, S. H.; Jang, G. S.

    1998-03-01

    It is necessary that development requirements, techniques to be developed, and development tasks and approach are established to develop the SMART instrumentation system. It is important to establish the development strategies for input for developing SMART instrumentation system. To meet above needs, the industry general and nuclear instrumentation techniques were analyzed and reviewed, respectively, based on the classification of instrumentation to analyze the industrial instrumentation techniques, and analysis results which described the inherent merits and demerits of each technique can be used for inputs to select the instruments for SMART. For the instrumentation techniques for nuclear environments, the major instrumentation techniques were reviewed, and the instrumentation system were established. The following development approaches were established based on the development requirements and the analysis results of research and development trends of industrial and nuclear instrumentation techniques. (author). 90 refs., 38 tabs., 33 figs

  13. Nanopositioning techniques development for synchrotron radiation instrumentation applications at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Shu Deming

    2010-01-01

    At modern synchrotron radiation sources and beamlines, high-precision positioning techniques present a significant opportunity to support state-of-the-art synchrotron radiation research. Meanwhile, the required instrument positioning performance and capabilities, such as resolution, dynamic range, repeatability, speed, and multiple axes synchronization are exceeding the limit of commercial availability. This paper presents the current nanopositioning techniques developed for the Argonne Center for Nanoscale Materials (CNM)/Advanced Photon Source (APS) hard x-ray nanoprobe and high-resolution x-ray monochromators and analyzers for the APS X-ray Operations and Research (XOR) beamlines. Future nanopositioning techniques to be developed for the APS renewal project will also be discussed.

  14. Fabrication of a metal-free ceramic restoration utilizing the monobloc technique.

    Science.gov (United States)

    Pissis, P

    1995-01-01

    This article presents a new technique which utilizes a porcelain core/crown unit, fabricated in the laboratory as a single component. The monobloc technique was developed by the author to replace the traditional metal post and core which prevents the transmission of light through porcelain crowns, creating a dark color effect. Between 1989 and 1992, a number of cases were successfully treated with several variations of the monobloc technique. Approximately 50 cases were completed with vitro-ceramic and followed up. The learning objective of this article is to introduce this novel technique. The article discusses the development of the technique, its advantages, disadvantages, and the potential failures. The clinical procedure is illustrated with several case presentations.

  15. Ex vivo evaluation of three instrumentation techniques on E. faecalis biofilm within oval shaped root canals

    Directory of Open Access Journals (Sweden)

    Vitor Cesar NAKAMURA

    2015-01-01

    Full Text Available The objective of the present study was to assess the effectiveness of reciprocating instrumentation in disinfecting oval-shaped root canals infected with Enterococcus faecalis. Forty-five human lower premolars were infected with a culture of E. faecalis (ATCC 29212 for 28 days. Five other teeth that were neither contaminated nor instrumented were used as controls. The 45 specimens were divided into three experimental groups (n = 15 based on the root canal preparation technique used: manual (K-type, Dentsply Maillefer, Ballaigues, Switzerland; rotary (MTwo, VDW GmbH, Munich, Germany; and reciprocating (Reciproc R50, VDW GmbH, Munich, Germany instruments. During chemomechanical preparation, 21 mL of 2.5% NaOCl was used as the irrigating solution. Microbiological sampling was performed before (S1 and immediately after (S2 the chemomechanical preparation using sterilized paper points. Specimens were then cleaved, and 0.02 g of dentine chips was collected from the root thirds to verify the presence of microorganisms in dentinal tubules. All three preparation techniques reduced the number of microorganisms in the root canal lumen and dentine chips from the root thirds, but no significant differences were observed between the three groups (p > 0.05. Reciprocating instrumentation with Reciproc R50 was effective in reducing the number of microorganisms within the root canal system. Although this technique involves the use of only one file to perform the root canal therapy, it is as effective as conventional rotary instrumentation in reducing theE. faecalis biofilm from the root canal system. However, further clinical investigations are warranted in order to ratify these results.

  16. SEM-based characterization techniques

    International Nuclear Information System (INIS)

    Russell, P.E.

    1986-01-01

    The scanning electron microscope is now a common instrument in materials characterization laboratories. The basic role of the SEM as a topographic imaging system has steadily been expanding to include a variety of SEM-based analytical techniques. These techniques cover the range of basic semiconductor materials characterization to live-time device characterization of operating LSI or VLSI devices. This paper introduces many of the more commonly used techniques, describes the modifications or additions to a conventional SEM required to utilize the techniques, and gives examples of the use of such techniques. First, the types of signals available from a sample being irradiated by an electron beam are reviewed. Then, where applicable, the type of spectroscopy or microscopy which has evolved to utilize the various signal types are described. This is followed by specific examples of the use of such techniques to solve problems related to semiconductor technology. Techniques emphasized include: x-ray fluorescence spectroscopy, electron beam induced current (EBIC), stroboscopic voltage analysis, cathodoluminescnece and electron beam IC metrology. Current and future trends of some of the these techniques, as related to the semiconductor industry are discussed

  17. An Automated Sorting System Based on Virtual Instrumentation Techniques

    Directory of Open Access Journals (Sweden)

    Rodica Holonec

    2008-07-01

    Full Text Available The application presented in this paper represents an experimental model and it refers to the implementing of an automated sorting system for pieces of same shape but different sizes and/or colors. The classification is made according to two features: the color and weight of these pieces. The system is a complex combination of NI Vision hardware and software tools, strain gauges transducers, signal conditioning connected to data acquisition boards, motion and control elements. The system is very useful for students to learn and experiment different virtual instrumentation techniques in order to be able to develop a large field of applications from inspection and process control to sorting and assembly

  18. Lumbar lordosis restoration following single-level instrumented fusion comparing 4 commonly used techniques.

    Science.gov (United States)

    Dimar, John R; Glassman, Steven D; Vemuri, Venu M; Esterberg, Justin L; Howard, Jennifer M; Carreon, Leah Y

    2011-11-09

    A major sequelae of lumbar fusion is acceleration of adjacent-level degeneration due to decreased lumbar lordosis. We evaluated the effectiveness of 4 common fusion techniques in restoring lordosis: instrumented posterolateral fusion, translumbar interbody fusion, anteroposterior fusion with posterior instrumentation, and anterior interbody fusion with lordotic threaded (LT) cages (Medtronic Sofamor Danek, Memphis, Tennessee). Radiographs were measured preoperatively, immediately postoperatively, and a minimum of 6 months postoperatively. Parameters measured included anterior and posterior disk space height, lumbar lordosis from L3 to S1, and surgical level lordosis.No significant difference in demographics existed among the 4 groups. All preoperative parameters were similar among the 4 groups. Lumbar lordosis at final follow-up showed no difference between the anteroposterior fusion with posterior instrumentation, translumbar interbody fusion, and LT cage groups, although the posterolateral fusion group showed a significant loss of lordosis (-10°) (Plordosis and showed maintenance of anterior and posterior disk space height postoperatively compared with the other groups. Instrumented posterolateral fusion produces a greater loss of lordosis compared with anteroposterior fusion with posterior instrumentation, translumbar interbody fusion, and LT cages. Maintenance of lordosis and anterior and posterior disk space height is significantly better with anterior interbody fusion with LT cages. Copyright 2011, SLACK Incorporated.

  19. INSTRUMENTS MEASURING PERCEIVED RACISM/RACIAL DISCRIMINATION: REVIEW AND CRITIQUE OF FACTOR ANALYTIC TECHNIQUES

    Science.gov (United States)

    Atkins, Rahshida

    2015-01-01

    Several compendiums of instruments that measure perceived racism and/or discrimination are present in the literature. Other works have reviewed the psychometric properties of these instruments in terms of validity and reliability and have indicated if the instrument was factor analyzed. However, little attention has been given to the quality of the factor analysis performed. The aim of this study was to evaluate the exploratory factor analyses done on instruments measuring perceived racism/racial discrimination using guidelines from experts in psychometric theory. The techniques used for factor analysis were reviewed and critiqued and the adequacy of reporting was evaluated. Internet search engines and four electronic abstract databases were used to identify 16 relevant instruments that met the inclusion/exclusion criteria. Principal component analysis was the most frequent method of extraction (81%). Sample sizes were adequate for factor analysis in 81 percent of studies. The majority of studies reported appropriate criteria for the acceptance of un-rotated factors (81%) and justified the rotation method (75%). Exactly 94 percent of studies reported partially acceptable criteria for the acceptance of rotated factors. The majority of articles (69%) reported adequate coefficient alphas for the resultant subscales. In 81 percent of the studies, the conceptualized dimensions were supported by factor analysis. PMID:25626225

  20. Nuclear measurements, techniques and instrumentation, industrial applications, plasma physics and nuclear fusion 1986-1996. International Atomic Energy Agency publications

    International Nuclear Information System (INIS)

    1997-03-01

    This catalogue lists all sales publications of the International Atomic Energy Agency dealing with Nuclear Measurements, Techniques, and Instrumentation, Industrial Applications, Plasma Physics and Nuclear Fusion, issued during the period 1986-1996. Most publications are in English. Proceedings of conferences, symposia and panels of experts may contain some papers in languages other than English (French, Russian or Spanish), but all of these papers have abstracts in English. Contents cover the three main areas of (i) Nuclear Measurements, Techniques and Instrumentation (Physics, Dosimetry Techniques, Nuclear Analytical Techniques, Research Reactor and Particle Accelerator Applications, and Nuclear Data), (ii) Industrial Applications (Radiation Processing, Radiometry, and Tracers), and (iii) Plasma Physics and Controlled Thermonuclear Fusion

  1. Contribution to applications of EBW in instrument techniques

    Science.gov (United States)

    Hrabovsky, Miroslav

    1999-07-01

    The electron beam welding belongs to so-called physical methods of welding and it is utilized to welding of most materials, that can be arc welded. It is of use there, where one taxing welding technics and structure technologyableless heavily. As a rule, the quality of weld is better than at most first-rate welds being done by inert gas shielded arc welding (WIG, Argoarc). In plant instrumentation, where the limitation of any welded material distortion is of extraordinary importance, this way of welding is significant at welding of thermal-treated Cu-Be alloys, used in measurement technics, structural members from Ti alloys and stainless steels in branches of biomedicine and cryotechnics. This technology positives, especially high weld purity, narrow and deep root penetration, high welding rate, together with low energy consumption, lead to applications and verification of optimum operating mode at welding of frequent materials. In the contribution the results of this proofs of selected welded materials from viewpoint of weld quality, their physical-mechanic properties and microhardness, are presented.

  2. Knowledge based expert system approach to instrumentation selection (INSEL

    Directory of Open Access Journals (Sweden)

    S. Barai

    2004-08-01

    Full Text Available The selection of appropriate instrumentation for any structural measurement of civil engineering structure is a complex task. Recent developments in Artificial Intelligence (AI can help in an organized use of experiential knowledge available on instrumentation for laboratory and in-situ measurement. Usually, the instrumentation decision is based on the experience and judgment of experimentalists. The heuristic knowledge available for different types of measurement is domain dependent and the information is scattered in varied knowledge sources. The knowledge engineering techniques can help in capturing the experiential knowledge. This paper demonstrates a prototype knowledge based system for INstrument SELection (INSEL assistant where the experiential knowledge for various structural domains can be captured and utilized for making instrumentation decision. In particular, this Knowledge Based Expert System (KBES encodes the heuristics on measurement and demonstrates the instrument selection process with reference to steel bridges. INSEL runs on a microcomputer and uses an INSIGHT 2+ environment.

  3. Utilization of artificial intelligence techniques for the Space Station power system

    Science.gov (United States)

    Evatt, Thomas C.; Gholdston, Edward W.

    1988-01-01

    Due to the complexity of the Space Station Electrical Power System (EPS) as currently envisioned, artificial intelligence/expert system techniques are being investigated to automate operations, maintenance, and diagnostic functions. A study was conducted to investigate this technology as it applies to failure detection, isolation, and reconfiguration (FDIR) and health monitoring of power system components and of the total system. Control system utilization of expert systems for load scheduling and shedding operations was also researched. A discussion of the utilization of artificial intelligence/expert systems for Initial Operating Capability (IOC) for the Space Station effort is presented along with future plans at Rocketdyne for the utilization of this technology for enhanced Space Station power capability.

  4. Olive oil sensory defects classification with data fusion of instrumental techniques and multivariate analysis (PLS-DA).

    Science.gov (United States)

    Borràs, Eva; Ferré, Joan; Boqué, Ricard; Mestres, Montserrat; Aceña, Laura; Calvo, Angels; Busto, Olga

    2016-07-15

    Three instrumental techniques, headspace-mass spectrometry (HS-MS), mid-infrared spectroscopy (MIR) and UV-visible spectrophotometry (UV-vis), have been combined to classify virgin olive oil samples based on the presence or absence of sensory defects. The reference sensory values were provided by an official taste panel. Different data fusion strategies were studied to improve the discrimination capability compared to using each instrumental technique individually. A general model was applied to discriminate high-quality non-defective olive oils (extra-virgin) and the lowest-quality olive oils considered non-edible (lampante). A specific identification of key off-flavours, such as musty, winey, fusty and rancid, was also studied. The data fusion of the three techniques improved the classification results in most of the cases. Low-level data fusion was the best strategy to discriminate musty, winey and fusty defects, using HS-MS, MIR and UV-vis, and the rancid defect using only HS-MS and MIR. The mid-level data fusion approach using partial least squares-discriminant analysis (PLS-DA) scores was found to be the best strategy for defective vs non-defective and edible vs non-edible oil discrimination. However, the data fusion did not sufficiently improve the results obtained by a single technique (HS-MS) to classify non-defective classes. These results indicate that instrumental data fusion can be useful for the identification of sensory defects in virgin olive oils. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Multielement comparison of instrumental neutron activation analysis techniques using reference materials

    International Nuclear Information System (INIS)

    Ratner, R.T.; Vernetson, W.G.

    1995-01-01

    Several instrumental neutron activation analysis techniques (parametric, comparative, and k o -standardization) are evaluated using three reference materials. Each technique is applied to National Institute of Standards and Technology standard reference materials, SRM 1577a (Bovine Liver) and SRM 2704 (Buffalo River Sediment), and the United States Geological Survey standard BHVO-1 (Hawaiian Basalt Rock). Identical (but not optimum) irradiation, decay, and counting schemes are employed with each technique to provide a basis for comparison and to determine sensitivities in a routine irradiation scheme. Fifty-one elements are used in this comparison; however, several elements are not detected in the reference materials due to rigid analytical conditions (e.g. insufficient length of irradiation or activity for radioisotope of interest decaying below the lower limit of detection before counting interval). Most elements are normally distributed around certified or consensus values with a standard deviation of 10%. For some elements, discrepancies are observed and discussed. The accuracy, precision, and sensitivity of each technique are discussed by comparing the analytical results to consensus values for the Hawaiian Basalt Rock to demonstrate the diversity of multielement applications. (author) 4 refs.; 2 tabs

  6. Fiber break location technique utilizing stimulated Brillouin scattering effects in optical fiber

    International Nuclear Information System (INIS)

    Bakar, A A A; Al-Mansoori, M H; Mahdi, M A; Mohd Azau, M A; Zainal Abidin, M S

    2009-01-01

    A new technique of fiber break detection system in optical communication networks is proposed and experimentally demonstrated in this paper. This technique is based-on continuous wave light source rather than pulsed source that is commonly deployed in existing techniques. The nonlinear effect of stimulated Brillouin scattering is manipulated to locate the fiber-break position in optical communication networks. This technique enables the utilization of a less-sensitive photodetector to detect the Brillouin Stokes line since its intensity increases with the fiber length in the detectable region. The fiber break location can be determined with accuracy of more than 98% for fiber length less than 50 km using this technique

  7. Validation of Reverse-Engineered and Additive-Manufactured Microsurgical Instrument Prototype.

    Science.gov (United States)

    Singh, Ramandeep; Suri, Ashish; Anand, Sneh; Baby, Britty

    2016-12-01

    With advancements in imaging techniques, neurosurgical procedures are becoming highly precise and minimally invasive, thus demanding development of new ergonomically aesthetic instruments. Conventionally, neurosurgical instruments are manufactured using subtractive manufacturing methods. Such a process is complex, time-consuming, and impractical for prototype development and validation of new designs. Therefore, an alternative design process has been used utilizing blue light scanning, computer-aided designing, and additive manufacturing direct metal laser sintering (DMLS) for microsurgical instrument prototype development. Deviations of DMLS-fabricated instrument were studied by superimposing scan data of fabricated instrument with the computer-aided designing model. Content and concurrent validity of the fabricated prototypes was done by a group of 15 neurosurgeons by performing sciatic nerve anastomosis in small laboratory animals. Comparative scoring was obtained for the control and study instrument. T test was applied to the individual parameters and P values for force (P direct application of these additive-manufactured instruments in the operating room requires further validation. © The Author(s) 2016.

  8. An in vitro study to determine fracture resistance of tooth roots after different instrumentation techniques

    Directory of Open Access Journals (Sweden)

    Marri Shilpa Reddy

    2016-01-01

    Conclusion: Preparation of canals with a conventional hand instrumentation technique using 0.02 taper K-files showed highest fracture resistance with least amount of dentin removed at all levels followed by Endowave, ProTaper Hand, and Rotary files.

  9. Current activities and plans for polarized neutron instruments of the JSNS/J-PARC project

    International Nuclear Information System (INIS)

    Furusaka, M.

    2005-01-01

    Neutron polarization is one of the key technologies for the next generation megawatt-class pulsed spallation neutron sources, such as SNS in the US and the JSNS in Japan. To polarize or analyze neutron spin, several techniques are under development in Japan: a small d-spacing magnetic multilayer mirror, spin exchange type He-3 filter and a dynamical proton polarizer. Several application techniques related to polarized neutrons are also under development, such as, a microwave-induced optical nuclear polarization technique, which allows us to polarize protons in naphtalene doped with pentacene at 77 K; neutron focusing-SANS instrument utilizing a focusing magnet; a Drabkin spin-filter instrument that has two filters in series for neutron-pulse shaping

  10. Thermal processes identification using virtual instrumentation

    Directory of Open Access Journals (Sweden)

    Iosif OLAH

    2007-12-01

    Full Text Available In this paper the experimental identification problem of thermal processes is presented, in order to establish their mathematical models which permit the adoption of the automation solutions, respectively the specification of a suitable control law. With this aim in view, the authors resorted to use Virtual Instrumentation with the aid of the LabVIEW development medium. In order to solve the problem of acquisition and processing data from physical real processes, Virtual Instruments which provide at the end a mathematical model which is basis of choosing the automation equipment of the aim followed was designed and achieved. The achieved Virtual Instruments get the opportunity to be used either in student instruction field with the virtual processes identification techniques or to put the identification of some real processes to good use of diverse beneficiaries. The results of some experimental attempts which were achieved during different thermal processes, illustrate the utility of the demarches performed in this paper.

  11. Developments in FT-ICR MS instrumentation, ionization techniques, and data interpretation methods for petroleomics.

    Science.gov (United States)

    Cho, Yunju; Ahmed, Arif; Islam, Annana; Kim, Sunghwan

    2015-01-01

    Because of the increasing importance of heavy and unconventional crude oil as an energy source, there is a growing need for petroleomics: the pursuit of more complete and detailed knowledge of the chemical compositions of crude oil. Crude oil has an extremely complex nature; hence, techniques with ultra-high resolving capabilities, such as Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), are necessary. FT-ICR MS has been successfully applied to the study of heavy and unconventional crude oils such as bitumen and shale oil. However, the analysis of crude oil with FT-ICR MS is not trivial, and it has pushed analysis to the limits of instrumental and methodological capabilities. For example, high-resolution mass spectra of crude oils may contain over 100,000 peaks that require interpretation. To visualize large data sets more effectively, data processing methods such as Kendrick mass defect analysis and statistical analyses have been developed. The successful application of FT-ICR MS to the study of crude oil has been critically dependent on key developments in FT-ICR MS instrumentation and data processing methods. This review offers an introduction to the basic principles, FT-ICR MS instrumentation development, ionization techniques, and data interpretation methods for petroleomics and is intended for readers having no prior experience in this field of study. © 2014 Wiley Periodicals, Inc.

  12. Using GPS instruments and GIS techniques in data management for insect pest control programs

    International Nuclear Information System (INIS)

    2006-01-01

    This interactive tutorial CD entitled 'Using GPS Instruments and GIS Techniques in Data Management for Insect Pest Control Programs' was developed by Micha silver of the Arava Development Co., Sapir, Israel, and includes step-by-step hands on lessons on the use of GPS/GIS in support of area-wide pest control operations

  13. Comparison of the Multiattribute Utility Instruments EQ-5D and SF-6D in a Europe-Wide Population-Based Cohort of Patients with Inflammatory Bowel Disease 10 Years after Diagnosis.

    Science.gov (United States)

    Huppertz-Hauss, Gert; Aas, Eline; Lie Høivik, Marte; Langholz, Ebbe; Odes, Selwyn; Småstuen, Milada; Stockbrugger, Reinhold; Hoff, Geir; Moum, Bjørn; Bernklev, Tomm

    2016-01-01

    Background. The treatment of chronic inflammatory bowel disease (IBD) is costly, and limited resources call for analyses of the cost effectiveness of therapeutic interventions. The present study evaluated the equivalency of the Short Form 6D (SF-6D) and the Euro QoL (EQ-5D), two preference-based HRQoL instruments that are broadly used in cost-effectiveness analyses, in an unselected IBD patient population. Methods. IBD patients from seven European countries were invited to a follow-up visit ten years after their initial diagnosis. Clinical and demographic data were assessed, and the Short Form 36 (SF-36) was employed. Utility scores were obtained by calculating the SF-6D index values from the SF-36 data for comparison with the scores obtained with the EQ-5D questionnaire. Results. The SF-6D and EQ-5D provided good sensitivities for detecting disease activity-dependent utility differences. However, the single-measure intraclass correlation coefficient was 0.58, and the Bland-Altman plot indicated numerous values beyond the limits of agreement. Conclusions. There was poor agreement between the measures retrieved from the EQ-5D and the SF-6D utility instruments. Although both instruments may provide good sensitivity for the detection of disease activity-dependent utility differences, the instruments cannot be used interchangeably. Cost-utility analyses performed with only one utility instrument must be interpreted with caution.

  14. Design techniques for modular integrated utility systems. [energy production and conversion efficiency

    Science.gov (United States)

    Wolfer, B. M.

    1977-01-01

    Features basic to the integrated utility system, such as solid waste incineration, heat recovery and usage, and water recycling/treatment, are compared in terms of cost, fuel conservation, and efficiency to conventional utility systems in the same mean-climatic area of Washington, D. C. The larger of the two apartment complexes selected for the test showed the more favorable results in the three areas of comparison. Restrictions concerning the sole use of currently available technology are hypothetically removed to consider the introduction and possible advantages of certain advanced techniques in an integrated utility system; recommendations are made and costs are estimated for each type of system.

  15. Nuclear measurements, techniques and instrumentation industrial applications plasma physics and nuclear fusion. 1980-1994. International Atomic Energy Agency publications

    International Nuclear Information System (INIS)

    1995-04-01

    This catalogue lists all sales publications of the International Atomic Energy Agency dealing with Nuclear Measurements, Techniques and Instrumentation, with Industrial Applications (of Nuclear Physics and Engineering), and with Plasma Physics and Nuclear Fusion, issued during the period 1980-1994. Most publications are in English. Proceedings of conferences, symposia, and panels of experts may contain some papers in other languages (French, Russian, or Spanish), but all papers have abstracts in English. Price quotes are in Austrian Schillings, do not include local taxes, and are subject to change without notice. Contents cover the three main categories of (i) Nuclear Measurements, Techniques and Instrumentation (Physics, Chemistry, Dosimetry Techniques, Nuclear Analytical Techniques, Research Reactors and Particle Accelerator Applications, Nuclear Data); (ii) Industrial Applications (Radiation Processing, Radiometry, Tracers); and (iii) Plasma Physics and Nuclear Fusion

  16. Nuclear measurements, techniques and instrumentation industrial applications plasma physics and nuclear fusion, 1980-1993. International Atomic Energy Agency publications

    International Nuclear Information System (INIS)

    1994-01-01

    This catalogue lists all sales publications of the International Atomic Energy Agency dealing with Nuclear Measurements, Techniques and Instrumentation, with Industrial Applications (of Nuclear Physics and Engineering), and with Plasma Physics and Nuclear Fusion, issued during the period 1980-1993. Most publications are in English. Proceedings of conferences, symposia, and panels of experts may contain some papers in other languages (French, Russian, or Spanish), but all papers have abstracts in English. Price quotes are in Austrian Schillings, do not include local taxes, and are subject to change without notice. Contents cover the three main categories of (I) Nuclear Measurements, Techniques and Instrumentation (Physics, Chemistry, Dosimetry Techniques, Nuclear Analytical Techniques, Research Reactors and Particle Accelerator Applications, Nuclear Data); (ii) Industrial Applications (Radiation Processing, Radiometry, Tracers); and (iii) Plasma Physics and Nuclear Fusion

  17. Volumetric analysis of hand, reciprocating and rotary instrumentation techniques in primary molars using spiral computed tomography: An in vitro comparative study.

    Science.gov (United States)

    Jeevanandan, Ganesh; Thomas, Eapen

    2018-01-01

    This present study was conducted to analyze the volumetric change in the root canal space and instrumentation time between hand files, hand files in reciprocating motion, and three rotary files in primary molars. One hundred primary mandibular molars were randomly allotted to one of the five groups. Instrumentation was done using Group I; nickel-titanium (Ni-Ti) hand file, Group II; Ni-Ti hand files in reciprocating motion, Group III; Race rotary files, Group IV; prodesign pediatric rotary files, and Group V; ProTaper rotary files. The mean volumetric changes were assessed using pre- and post-operative spiral computed tomography scans. Instrumentation time was recorded. Statistical analysis to access intergroup comparison for mean canal volume and instrumentation time was done using Bonferroni-adjusted Mann-Whitney test and Mann-Whitney test, respectively. Intergroup comparison of mean canal volume showed statistically significant difference between Groups II versus IV, Groups III versus V, and Groups IV versus V. Intergroup comparison of mean instrumentation time showed statistically significant difference among all the groups except Groups IV versus V. Among the various instrumentation techniques available, rotary instrumentation is the considered to be the better instrumentation technique for canal preparation in primary teeth.

  18. Evaluation of three instrumentation techniques at the precision of apical stop and apical sealing of obturation

    Directory of Open Access Journals (Sweden)

    Özgür Genç

    2011-08-01

    Full Text Available OBJECTIVE: The aim of this study was to investigate the ability of two NiTi rotary apical preparation techniques used with an electronic apex locator-integrated endodontic motor and a manual technique to create an apical stop at a predetermined level (0.5 mm short of the apical foramen in teeth with disrupted apical constriction, and to evaluate microleakage following obturation in such prepared teeth. MATERIAL AND METHODS: 85 intact human mandibular permanent incisors with single root canal were accessed and the apical constriction was disrupted using a #25 K-file. The teeth were embedded in alginate and instrumented to #40 using rotary Lightspeed or S-Apex techniques or stainless-steel K-files. Distance between the apical foramen and the created apical stop was measured to an accuracy of 0.01 mm. In another set of instrumented teeth, root canals were obturated using gutta-percha and sealer, and leakage was tested at 1 week and 3 months using a fluid filtration device. RESULTS: All techniques performed slightly short of the predetermined level. Closest preparation to the predetermined level was with the manual technique and the farthest was with S-Apex. A significant difference was found between the performances of these two techniques (p<0.05. Lightspeed ranked in between. Leakage was similar for all techniques at either period. However, all groups leaked significantly more at 3 months compared to 1 week (p<0.05. CONCLUSIONS: Despite statistically significant differences found among the techniques, deviations from the predetermined level were small and clinically acceptable for all techniques. Leakage following obturation was comparable in all groups.

  19. Instrumentation for studying binder burnout in an immobilized plutonium ceramic wasteform

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, M; Pugh, D; Herman, C

    2000-04-21

    The Plutonium Immobilization Program produces a ceramic wasteform that utilizes organic binders. Several techniques and instruments were developed to study binder burnout on full size ceramic samples in a production environment. This approach provides a method for developing process parameters on production scale to optimize throughput, product quality, offgas behavior, and plant emissions. These instruments allow for offgas analysis, large-scale TGA, product quality observation, and thermal modeling. Using these tools, results from lab-scale techniques such as laser dilametry studies and traditional TGA/DTA analysis can be integrated. Often, the sintering step of a ceramification process is the limiting process step that controls the production throughput. Therefore, optimization of sintering behavior is important for overall process success. Furthermore, the capabilities of this instrumentation allows better understanding of plant emissions of key gases: volatile organic compounds (VOCs), volatile inorganics including some halide compounds, NO{sub x}, SO{sub x}, carbon dioxide, and carbon monoxide.

  20. Using the in situ lift-out technique to prepare TEM specimens on a single-beam FIB instrument

    International Nuclear Information System (INIS)

    Lekstrom, M; McLachlan, M A; Husain, S; McComb, D W; Shollock, B A

    2008-01-01

    Transmission electron microscope (TEM) specimens are today routinely prepared using focussed ion beam (FIB) instruments. Specifically, the lift-out method has become an increasingly popular technique and involves removing thin cross-sections from site-specific locations and transferring them to a TEM grid. This lift-out process can either be performed ex situ or in situ. The latter is mainly carried out on combined dual-beam FIB and scanning electron microscope (SEM) systems whereas conventional single-beam instruments often are limited to the traditional ex situ method. It is nevertheless desirable to enhance the capabilities of existing single-beam instruments to allow for in situ lift-out preparation to be performed since this technique offers a number of advantages over the older ex situ method. A single-beam FIB instrument was therefore modified to incorporate an in situ micromanipulator fitted with a tungsten needle, which can be attached to a cut-out FIB section using ion beam induced platinum deposition. This article addresses the issues of using an ion beam to monitor the in situ manipulation process as well as approaches that can be used to create stronger platinum welds between two objects, and finally, views on how to limit the extent of ion beam damage to the specimen surface.

  1. Comparison of the Multiattribute Utility Instruments EQ-5D and SF-6D in a Europe-Wide Population-Based Cohort of Patients with Inflammatory Bowel Disease 10 Years after Diagnosis

    Directory of Open Access Journals (Sweden)

    Gert Huppertz-Hauss

    2016-01-01

    Full Text Available Background. The treatment of chronic inflammatory bowel disease (IBD is costly, and limited resources call for analyses of the cost effectiveness of therapeutic interventions. The present study evaluated the equivalency of the Short Form 6D (SF-6D and the Euro QoL (EQ-5D, two preference-based HRQoL instruments that are broadly used in cost-effectiveness analyses, in an unselected IBD patient population. Methods. IBD patients from seven European countries were invited to a follow-up visit ten years after their initial diagnosis. Clinical and demographic data were assessed, and the Short Form 36 (SF-36 was employed. Utility scores were obtained by calculating the SF-6D index values from the SF-36 data for comparison with the scores obtained with the EQ-5D questionnaire. Results. The SF-6D and EQ-5D provided good sensitivities for detecting disease activity-dependent utility differences. However, the single-measure intraclass correlation coefficient was 0.58, and the Bland-Altman plot indicated numerous values beyond the limits of agreement. Conclusions. There was poor agreement between the measures retrieved from the EQ-5D and the SF-6D utility instruments. Although both instruments may provide good sensitivity for the detection of disease activity-dependent utility differences, the instruments cannot be used interchangeably. Cost-utility analyses performed with only one utility instrument must be interpreted with caution.

  2. Effect of Instrumentation Techniques, Irrigant Solutions and Artificial accelerated Aging on Fiberglass Post Bond Strength to Intraradicular Dentin.

    Science.gov (United States)

    Santana, Fernanda Ribeiro; Soares, Carlos José; Silva, Júlio Almeida; Alencar, Ana Helena Gonçalves; Renovato, Sara Rodrigues; Lopes, Lawrence Gonzaga; Estrela, Carlos

    2015-07-01

    To evaluate the effect of instrumentation techniques, irrigant solutions and specimen aging on fiberglass posts bond strength to intraradicular dentine. A total of 120 bovine teeth were prepared and randomized into control and experimental groups resulting from three study factors (instrumentation techniques, irrigant solutions, specimen aging). Posts were cemented with RelyX U100. Samples were submitted to push-out test and failure mode was evaluated under a confocal microscope. In specimens submitted to water artificial aging, nickel-titanium rotary instruments group presented higher bond strength values in apical third irrigated with NaOCl or chlorhexi-dine. Irrigation with NaOCl resulted in higher bond strength than ozonated water. Artificial aging resulted in significant bond strength increase. Adhesive cement-dentin failure was prevalent in all the groups. Root canal preparation with NiTi instruments associated with NaOCl irrigation and ethylenediaminetetra acetic acid (EDTA) increased bond strength of fiberglass posts cemented with self-adhesive resin cement to intraradicular dentine. Water artificial aging significantly increased post-Clinical significance: The understanding of factors that may influence the optimal bond between post-cement and cement-dentin are essential to the success of endodontically treated tooth restoration.

  3. Evaluation of apically extruded debris during removal of gutta-percha and ResilonTM using different instrumentation techniques

    Directory of Open Access Journals (Sweden)

    Pešić Dragana

    2018-01-01

    Full Text Available Background/Aim. Apical extrusion of material is considered as one of the very important factor for endodontic treatment success. Microorganisms, necrotic tissue, filling material and irrigants, which can be extruded apically during endodontic retreatment, may jeopardize the success of the therapy. The aim of this in vitro study was to quantitatively evaluate the amount of apically extruded debris during endodontic retreatment of teeth obturated with two different materials, using one hand and three rotary instrumentation techniques. Methods. Ninety-six extracted single-rooted teeth were endodontically treated and enlarged to size 40 using BioRaCe system, and then randomly divided into 8 groups of 12 specimens each. Half of the specimens were obturated with gutta-percha and AH Plus® sealer and another half with RealSeal SE system, using lateral condensation technique. Retreatment was performed using: Hedström files; ProFile rotary files; ProTaper Retreatment system and D-RaCe system. Apically extruded debris was collected in pre-weighed Eppendorf tubes and evaluated using an electronic microbalance. Data were analyzed statistically using t-test and analysis of variance. Results. In the AH Plus/gutta-percha group, all tested rotary instruments gave significantly less extruded debris compared with Hedström files (p < 0.05. In theRealSeal group, there was significant difference between DRaCe and Hedström instruments (p < 0.05. Conclusion. All retreatment techniques resulted in apical extrusion. DRaCe system produced significantly less extruded debris compared to hand files. No significant difference was found when comparing two instruments specially designed for retreatment: D-RaCe and ProTaper systems.

  4. New anastomosis technique for (laparoscopic) instrumental small-diameter anastomosis.

    Science.gov (United States)

    Schöb, O; Schmid, R; Schlumpf, R; Klotz, H P; Spiess, M; Largiadèr, F

    1995-04-01

    This study presents a new technique for visceral anastomosis. The principle consists of connecting the two parts to be anastomosed around a reabsorbable stent which is transluminally introduced into small-diameter viscus, where it is fixed. Advancing a larger tube along the axis of the machine, the larger, perforated viscus is inverted and pulled over the stent, and finally a rubber band pops off the machine endoluminally in order to fix the intestinal walls in seroserosal contact onto the stent. To evaluate this "micro" anastomosis, a biliary bypass (choledochojejunostomy and roux-en-y-loop) was performed in ten pigs. Nine of ten animals showed biliary bypass with good runoff in contrast radiography and completely reabsorbed stent after a 3-month follow-up. Weight gain, bilirubin, and alkaline phosphatase were normal. This technology demonstrates a safe and quick way to perform instrumental "micro" anastomosis without remnant foreign material.

  5. Development of source range measurement instrument in Xi'an pulsed reactor

    CERN Document Server

    Wang Li

    2002-01-01

    Source range measurement instrument in Xi'an pulsed reactor is key equipment of low-side measuring in source range. At the same time, it is also weighty component of out-of-pile neutron-flux level observation system. The authors have done some researching and renovating based on the similar type devices used in nuclear reactor to improve the meter sensitivity, measuring range, noise proof features, reliability in running and maintainability which belong to the main performance index of the instrument. The design ideas, configurations, working principle, performance indexes, technique features and effect in utilizing are introduced briefly

  6. Instrumentation reference book

    CERN Document Server

    Boyes, Walt

    2002-01-01

    Instrumentation is not a clearly defined subject, having a 'fuzzy' boundary with a number of other disciplines. Often categorized as either 'techniques' or 'applications' this book addresses the various applications that may be needed with reference to the practical techniques that are available for the instrumentation or measurement of a specific physical quantity or quality. This makes it of direct interest to anyone working in the process, control and instrumentation fields where these measurements are essential.* Comprehensive and authoritative collection of technical information* Writte

  7. [Development and validation of an instrument for initial nursing assessment].

    Science.gov (United States)

    Fernández-Sola, Cayetano; Granero-Molina, José; Mollinedo-Mallea, Judith; de Gonzales, María Hilda Peredo; Aguilera-Manrique, Gabriel; Ponce, Mara Luna

    2012-12-01

    The objective of this study, conducted in Bolivia from April to July of 2008, is the design and validation of an initial nursing assessment instrument to be used in clinical and educational environments in Santa Cruz (Bolivia). Twelve Bolivian nurses participated; both document analysis as well as consensus techniques were used to determine the categories and criteria to be assessed. Categories included in the nursing assessment instrument are a physical assessment and the eleven Gordon's Functional Health Patterns. The nursing assessment instrument stands out as being concise, easy to complete and utilizing a nursing approach. It does not include items for advanced nursing assessment. However, it incorporates items regarding lifestyle and the patient's autonomy. The nursing assessment instrument contributes to improving the quality of clinical records, supports the nursing diagnosis and implementation of the nursing process, promotes the nurse's role and helps to standardize practice.

  8. Utilization of analytical techniques in aid the implantation of nuclear installations

    International Nuclear Information System (INIS)

    Ferreira, M.P.; Sabino, C.V.S.; Avelar, M.M.

    1984-01-01

    Nuclear, physico-chemical and classic techniques developed and utilized by Centro de Desenvolvimento de Tecnicas Nucleares are presented, as back up to the implementation and operation of nuclear installations related with several parts of fuel cycle from uranium prospecting to waste treatment samples of soils, ores, alloys, plastics, paints, biological materials, air and water were analysed. (M.C.K) [pt

  9. A Limited Submuscular Direct-to-Implant Technique Utilizing AlloMax

    Directory of Open Access Journals (Sweden)

    Michal Brichacek, MD

    2017-07-01

    Full Text Available Background:. This study evaluates a novel limited submuscular direct-to-implant technique utilizing AlloMax where only the upper few centimeters of the implant is covered by the pectoralis, whereas the majority of the implant including the middle and lower poles are covered by acellular dermal matrix. Methods:. The pectoralis muscle is released off its inferior and inferior-medial origins and allowed to retract superiorly. Two sheets of AlloMax (6 × 16 cm are sutured together and secured to the inframammary fold, serratus fascia, and the superiorly retracted pectoralis. Thirty-seven breasts in 19 consecutive patients with follow-up at 6 months were reviewed. Results:. Nineteen consecutive patients with 37 reconstructed breasts were studied. Average age was 50 years, average BMI was 24.3. Ptosis ranged from grade 0–III, and average cup size was B (range, A–DDD. Early minor complications included 1 seroma, 3 minor postoperative hematomas managed conservatively, and 3 minor wound healing problems. Three breasts experienced mastectomy skin flap necrosis and were managed with local excision. There were no cases of postoperative infection, red breast, grade III/IV capsular contractures, or implant loss. A single patient complained of animation postoperatively. One patient desired fat grafting for rippling. Conclusions:. The limited submuscular direct-to-implant technique utilizing AlloMax appears to be safe with a low complication rate at 6 months. This technique minimizes the action of the pectoralis on the implant, reducing animation deformities but still providing muscle coverage of the upper limit of the implant. Visible rippling is reduced, and a vascularized bed remains for fat grafting of the upper pole if required.

  10. Mobile instrumentation platform and robotic accessory for real-time screening of hazardous waste

    International Nuclear Information System (INIS)

    Anderson, M.S.; Jaselskis, E.J.

    1992-01-01

    An innovative mobile laboratory for real-time field screening of soils for inorganic hazardous waste using laser ablation-inductively coupled plasma-atomic emission spectrometry sampling and analysis technique is being developed at Ames Laboratory. This sampling technique as well as the concept for installing, monitoring, and controlling the instrumentation and utilities in the mobile laboratory, the robotic sampling accessory, and manual sampling method are discussed. Benefits of this mobile configuration and future development plans also are described

  11. Synchrotron radiation microtomography of musical instruments: a non-destructive monitoring technique for insect infestations

    Directory of Open Access Journals (Sweden)

    Beatrice Bentivoglio-Ravasio

    2011-08-01

    Full Text Available X-ray computed tomography is becoming a common technique for the structural analysis of samples of cultural relevance, providing luthiers, art historians, conservators and restorators with a unique tool for the characterization of musical instruments. Synchrotron-radiation phase-contrast microtomography is an ideal technique for the non-destructive 3D analysis of samples where small lowabsorbing details such as larvae and eggs can be detected. We report results from the first feasibility studies performed at the Elettra synchrotron laboratory, where the 1494 organ by Lorenzo Gusnasco da Pavia has been studied. Together with important information about the structural conditions, the presence of xylophages could be detected and characterized.

  12. The effect of a manual instrumentation technique on five types of premolar root canal geometry assessed by microcomputed tomography and three-dimensional reconstruction

    International Nuclear Information System (INIS)

    Li, Ke-Zeng; Gao, Yuan; Zhang, Ru; Hu, Tao; Guo, Bin

    2011-01-01

    Together with diagnosis and treatment planning, a good knowledge of the root canal system and its frequent variations is a necessity for successful root canal therapy. The selection of instrumentation techniques for variants in internal anatomy of teeth has significant effects on the shaping ability and cleaning effectiveness. The aim of this study was to reveal the differences made by including variations in the internal anatomy of premolars into the study protocol for investigation of a single instrumentation technique (hand ProTaper instruments) assessed by microcomputed tomography and three-dimensional reconstruction. Five single-root premolars, whose root canal systems were classified into one of five types, were scanned with micro-CT before and after preparation with a hand ProTaper instrument. Instrumentation characteristics were measured quantitatively in 3-D using a customized application framework based on MeVisLab. Numeric values were obtained for canal surface area, volume, volume changes, percentage of untouched surface, dentin wall thickness, and the thickness of dentin removed. Preparation errors were also evaluated using a color-coded reconstruction. Canal volumes and surface areas were increased after instrumentation. Prepared canals of all five types were straightened, with transportation toward the inner aspects of S-shaped or multiple curves. However, a ledge was formed at the apical third curve of the type II canal system and a wide range in the percentage of unchanged canal surfaces (27.4-83.0%) was recorded. The dentin walls were more than 0.3 mm thick except in a 1 mm zone from the apical surface and the hazardous area of the type II canal system after preparation with an F3 instrument. The 3-D color-coded images showed different morphological changes in the five types of root canal systems shaped with the same hand instrumentation technique. Premolars are among the most complex teeth for root canal treatment and instrumentation techniques

  13. The effect of a manual instrumentation technique on five types of premolar root canal geometry assessed by microcomputed tomography and three-dimensional reconstruction

    Directory of Open Access Journals (Sweden)

    Hu Tao

    2011-06-01

    Full Text Available Abstract Background Together with diagnosis and treatment planning, a good knowledge of the root canal system and its frequent variations is a necessity for successful root canal therapy. The selection of instrumentation techniques for variants in internal anatomy of teeth has significant effects on the shaping ability and cleaning effectiveness. The aim of this study was to reveal the differences made by including variations in the internal anatomy of premolars into the study protocol for investigation of a single instrumentation technique (hand ProTaper instruments assessed by microcomputed tomography and three-dimensional reconstruction. Methods Five single-root premolars, whose root canal systems were classified into one of five types, were scanned with micro-CT before and after preparation with a hand ProTaper instrument. Instrumentation characteristics were measured quantitatively in 3-D using a customized application framework based on MeVisLab. Numeric values were obtained for canal surface area, volume, volume changes, percentage of untouched surface, dentin wall thickness, and the thickness of dentin removed. Preparation errors were also evaluated using a color-coded reconstruction. Results Canal volumes and surface areas were increased after instrumentation. Prepared canals of all five types were straightened, with transportation toward the inner aspects of S-shaped or multiple curves. However, a ledge was formed at the apical third curve of the type II canal system and a wide range in the percentage of unchanged canal surfaces (27.4-83.0% was recorded. The dentin walls were more than 0.3 mm thick except in a 1 mm zone from the apical surface and the hazardous area of the type II canal system after preparation with an F3 instrument. Conclusions The 3-D color-coded images showed different morphological changes in the five types of root canal systems shaped with the same hand instrumentation technique. Premolars are among the most

  14. Final report, Ames Mobile Laboratory Project: The development and operation of instrumentation in a mobile laboratory for in situ, real-time screening and characterization of soils using the laser ablation sampling technique

    International Nuclear Information System (INIS)

    Anderson, M.S.; Braymen, S.D.

    1995-01-01

    The main focus of the Ames Laboratory's Technology Integration Program, TIP, from May 1991 through December 1994 was the development, fabrication, and demonstration of a mobile instrumentation laboratory incorporating rapid in situ sampling systems for safe, rapid, and cost effective soil screening/characterization. The Mobile Demonstration Laboratory for Environmental Screening Technologies, MDLEST, containing the analysis instrumentation, along with surface and subsurface sampling probe prototypes employing the laser ablation sampling technique were chosen to satisfy the particular surface and subsurface soil characterization needs of the various Department of Energy facilities for determining the extent of heavy metal and radionuclide contamination. The MDLEST, a 44 foot long 5th wheel trailer, is easily configured for the analysis instrumentation and sampling system required for the particular site work. This mobile laboratory contains all of the utilities needed to satisfy the operating requirements of the various instrumentation installed. These utilities include, an electric generator, a chilled water system, process gases, a heating/air conditioning system, and computer monitoring and automatic operating systems. Once the MDLEST arrives at the job site, the instrumentation is aligned and calibration is completed, sampling and analysis operations begin. The sample is acquired, analyzed and the results reported in as little as 10 minutes. The surface sampling probe is used in two modes to acquire samples for analysis. It is either set directly on the ground over the site to be sampled, in situ sampling, or in a special fixture used for calibrating the sampling analysis system with standard soil samples, having the samples brought to the MDLEST. The surface sampling probe was used to in situ sample a flat concrete surface (nondestructively) with the ablated sample being analyzed by the instrumentation in the MDLEST

  15. Utilization technique for advanced nuclear materials database system Data-Free-Way'

    International Nuclear Information System (INIS)

    Fujita, Mitsutane; Kurihara, Yutaka; Kinugawa, Junichi; Kitajima, Masahiro; Nagakawa, Josei; Yamamoto, Norikazu; Noda, Tetsuji; Yagi, Koichi; Ono, Akira

    2001-01-01

    Four organizations the National Research Institute for Metals (NRIM), the Japan Atomic Energy Research Institute (JAERI), the Japan Nuclear Fuel Cycle Development Institute (JNC) and Japan Science and Technology Incorporation (JST), conducted the 2nd period joint research for the purpose of development of utilization techniques for advanced nuclear materials database system named 'Data-Free-Way' (DFW), to make more useful system to support research and development of the nuclear materials, from FY 1995 to FY 1999. NRIM intended to fill a data system on diffusion and nuclear data by developing utilization technique on diffusion informations of steels and aluminum and nuclear data for materials for its independent system together with participating in fulfil of the DFW. And, NRIM has entered to a project on wide area band circuit application agreed at the G7 by using technologies cultivated by NRIM, to investigate network application technology with the Michigan State University over the sea under cooperation assistant business of JST, to make results on CCT diagram for welding and forecasting of welding heat history accumulated at NRIM for a long term, to perform development of a simulator assisting optimum condition decision of welding. (G.K.)

  16. A review of modern instrumental techniques for measurements of ice cream characteristics.

    Science.gov (United States)

    Bahram-Parvar, Maryam

    2015-12-01

    There is an increasing demand of the food industries and research institutes to have means of measurement allowing the characterization of foods. Ice cream, as a complex food system, consists of a frozen matrix containing air bubbles, fat globules, ice crystals, and an unfrozen serum phase. Some deficiencies in conventional methods for testing this product encourage the use of alternative techniques such as rheometry, spectroscopy, X-ray, electro-analytical techniques, ultrasound, and laser. Despite the development of novel instrumental applications in food science, use of some of them in ice cream testing is few, but has shown promising results. Developing the novel methods should increase our understanding of characteristics of ice cream and may allow online testing of the product. This review article discusses the potential of destructive and non-destructive methodologies in determining the quality and characteristics of ice cream and similar products. Copyright © 2015. Published by Elsevier Ltd.

  17. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  18. The learning curve of the three-port two-instrument complete thoracoscopic lobectomy for lung cancer—A feasible technique worthy of popularization

    Directory of Open Access Journals (Sweden)

    Yu-Jen Cheng

    2015-07-01

    Conclusion: Three-port complete thoracoscopic lobectomy with the two-instrument technique is feasible for lung cancer treatment. The length of the learning curve consisted of 28 cases. This TPTI technique should be popularized.

  19. Instrumentation a reader

    CERN Document Server

    Pope, P

    1990-01-01

    This book contains a selection of papers and articles in instrumentation previously pub­ lished in technical periodicals and journals of learned societies. Our selection has been made to illustrate aspects of current practice and applications of instrumentation. The book does not attempt to be encyclopaedic in its coverage of the subject, but to provide some examples of general transduction techniques, of the sensing of particular measurands, of components of instrumentation systems and of instrumentation practice in two very different environments, the food industry and the nuclear power industry. We have made the selection particularly to provide papers appropriate to the study of the Open University course T292 Instrumentation. The papers have been chosen so that the book covers a wide spectrum of instrumentation techniques. Because of this, the book should be of value not only to students of instrumen­ tation, but also to practising engineers and scientists wishing to glean ideas from areas of instrumen...

  20. On-line calibration of process instrumentation channels in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hashemian, H.M.; Farmer, J.P. [Analysis and Measurement Services Corp., Knoxville, TN (United States)

    1995-04-01

    An on-line instrumentation monitoring system was developed and validated for use in nuclear power plants. This system continuously monitors the calibration status of instrument channels and determines whether or not they require manual calibrations. This is accomplished by comparing the output of each instrument channel to an estimate of the process it is monitoring. If the deviation of the instrument channel from the process estimate is greater than an allowable limit, then the instrument is said to be {open_quotes}out of calibration{close_quotes} and manual adjustments are made to correct the calibration. The success of the on-line monitoring system depends on the accuracy of the process estimation. The system described in this paper incorporates both simple intercomparison techniques as well as analytical approaches in the form of data-driven empirical modeling to estimate the process. On-line testing of the calibration of process instrumentation channels will reduce the number of manual calibrations currently performed, thereby reducing both costs to utilities and radiation exposure to plant personnel.

  1. Trace elements in California aerosols. Part I. Instrumental neutron activation analysis techniques

    International Nuclear Information System (INIS)

    Ragaini, R.C.; Ralston, H.R.; Garvis, D.; Kaifer, R.

    1975-01-01

    Instrumental Neutron Activation Analysis (INAA) done at LLL played a key role in the 1972--1974 California Aerosol Characterization Experiment (ACHEX), a major experiment in the chemistry of aerosols in urban and non-urban sites of California sponsored by the State of California Air Resources Board. The main purpose of INAA was to measure the particle size distributions and diurnal patterns of key chemical constituents in aerosols collected in California. These data were used to satisfy some of the key objectives of ACHEX, including aerosol characterization and evaluation of the origins and evolutions of aerosols. Secondary uses of INAA were the validations of the Lundgren rotating drum cascade impactors used in the ACHEX, and validations of other analytical techniques used in the chemical analyses. As a result of these studies, it was concluded that techniques using INAA were useful operational methods for chemical analysis of aerosols collected over two-hour periods in urban air with an active monitoring program. (U.S.)

  2. Development of 40m SANS and Its Utilization Techniques

    International Nuclear Information System (INIS)

    Choi, Sung Min; Kim, Tae Hwan

    2010-06-01

    Small angle neutron scattering (SANS) has been a very powerful tool to study nanoscale (1-100 nm) bulk structures in various materials such as polymer, self assembled materials, nano-porous materials, nano-magnetic materials, metal and ceramics. Understanding the importance of the SANS instrument, the 8m SANS instrument was installed at the CN beam port of HANARO in 2001. However, without having a cold neutron source, the beam intensity is fairly low and the Q-range is rather limited due to short instrument length. In July 1, 2003, therefore, the HANARO cold neutron research facility project was launched and a state of the art 40m SANS instrument was selected as top-priority instrument. The development of the 40m SANS instrument was completed as a joint project between Korea Advanced Institute of Science and Technology and the HANARO in 2010. Here, we report the specification of a state of art 40m SANS instrument at HANARO

  3. Outcomes and Resource Utilization of Endoscopic Mass-Closure Technique for Laryngeal Clefts.

    Science.gov (United States)

    Balakrishnan, Karthik; Cheng, Esther; de Alarcon, Alessandro; Sidell, Douglas R; Hart, Catherine K; Rutter, Michael J

    2015-07-01

    To compare resource utilization and clinical outcomes between endoscopic mass-closure and open techniques for laryngeal cleft repair. Case series with chart review. Tertiary academic children's hospital. Pediatric patients undergoing repair for Benjamin-Inglis type 1-3 laryngeal clefts over a 15-year period. All 20 patients undergoing endoscopic repair were included. Eight control patients undergoing open repair were selected using matching by age and cleft type. Demographic, clinical, and resource utilization data were collected. Twenty-eight patients were included (20 endoscopic, 8 open). Mean age, rates of tracheostomy and vocal fold immobility, and distribution of cleft types were not different between the 2 groups (all P > .2). Mean operative time (P = .004) and duration of hospital stay (P group. All repairs were intact in both groups at final postoperative endoscopy. Rates of persistent laryngeal penetration or aspiration on swallow study were not different between groups (P = 1.000), although results were available for only 11 patients. Endoscopic laryngeal cleft repair using a mass-closure technique provides a durable result while requiring significantly shorter operative times and hospital stays than open repair and avoiding the potential morbidity of laryngofissure. However, open repair may allow the simultaneous performance of other airway reconstructive procedures and may be a useful salvage technique when endoscopic repair fails. Postoperative swallowing results require further study. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  4. Development of performance test instrument in the experiment of law of conservation mass using self and peer assessment’s technique

    Science.gov (United States)

    Siswaningsih, W.; Nahadi; Firmansyah, D. R.

    2018-05-01

    The purpose of this research is to develop the instrument of performance assessment of law of mass conservation using self and peer assessment technique that meet valid and reliable criteria. The instrument components consist of task and rubric. The method used is development and validation.Value of the instrument reliability obtained from twice observations that are at four and six students every group with three same observers. Cronbach alpha value for four and six students every group consecutively are 0.94 and 0.76, indicating that value shows that the instrument is reliable. Optimum amount of the students that can be observed are four students. The implementation of the instrument to limited group of students showed that All of the students give positive responses to the instrument used with the interpretation of questionnaire scores >90% that categorized as good.

  5. Proceedings of the advanced research and technology development direct utilization, instrumentation and diagnostics contractors' review meeting

    Energy Technology Data Exchange (ETDEWEB)

    Geiling, D.W. (USDOE Morgantown Energy Technology Center, WV (USA)); Goldberg, P.M. (eds.) (USDOE Pittsburgh Energy Technology Center, PA (USA))

    1990-01-01

    The 1990 Advanced Research and Technology Development (AR TD) Direct Utilization, and Instrumentation and Diagnostics Contractors Review Meeting was held September 16--18, 1990, at the Hyatt at Chatham Center in Pittsburgh, PA. The meeting was sponsored by the US Department of Energy (DOE), Office of Fossil Energy, and the Pittsburgh and Morgantown Energy Technology Centers. Each year the meeting provides a forum for the exchange of information among the DOE AR TD contractors and interested parties. This year's meeting was hosted by the Pittsburgh Energy Technology Center and was attended by 120 individuals from industry, academia, national laboratories, and other governmental agencies. Papers were presented on research addressing coal surface, science, devolatilization and combustion, ash behavior, emission controls for gases particulates, fluid bed combustion and utilization in diesels and turbines. Individual reports are processed separately for the data bases.

  6. Decoupling Solar Variability and Instrument Trends Using the Multiple Same-Irradiance-Level (MuSIL) Analysis Technique

    Science.gov (United States)

    Woods, Thomas N.; Eparvier, Francis G.; Harder, Jerald; Snow, Martin

    2018-05-01

    The solar spectral irradiance (SSI) dataset is a key record for studying and understanding the energetics and radiation balance in Earth's environment. Understanding the long-term variations of the SSI over timescales of the 11-year solar activity cycle and longer is critical for many Sun-Earth research topics. Satellite measurements of the SSI have been made since the 1970s, most of them in the ultraviolet, but recently also in the visible and near-infrared. A limiting factor for the accuracy of previous solar variability results is the uncertainties for the instrument degradation corrections, which need fairly large corrections relative to the amount of solar cycle variability at some wavelengths. The primary objective of this investigation has been to separate out solar cycle variability and any residual uncorrected instrumental trends in the SSI measurements from the Solar Radiation and Climate Experiment (SORCE) mission and the Thermosphere, Mesosphere, Ionosphere, Energetic, and Dynamics (TIMED) mission. A new technique called the Multiple Same-Irradiance-Level (MuSIL) analysis has been developed, which examines an SSI time series at different levels of solar activity to provide long-term trends in an SSI record, and the most common result is a downward trend that most likely stems from uncorrected instrument degradation. This technique has been applied to each wavelength in the SSI records from SORCE (2003 - present) and TIMED (2002 - present) to provide new solar cycle variability results between 27 nm and 1600 nm with a resolution of about 1 nm at most wavelengths. This technique, which was validated with the highly accurate total solar irradiance (TSI) record, has an estimated relative uncertainty of about 5% of the measured solar cycle variability. The MuSIL results are further validated with the comparison of the new solar cycle variability results from different solar cycles.

  7. Instrumentation, computer software and experimental techniques used in low-frequency internal friction studies at WNRE

    International Nuclear Information System (INIS)

    Sprugmann, K.W.; Ritchie, I.G.

    1980-04-01

    A detailed and comprehensive account of the equipment, computer programs and experimental methods developed at the Whiteshell Nuclear Research Estalbishment for the study of low-frequency internal friction is presented. Part 1 describes the mechanical apparatus, electronic instrumentation and computer software, while Part II describes in detail the laboratory techniques and various types of experiments performed together with data reduction and analysis. Experimental procedures for the study of internal friction as a function of temperature, strain amplitude or time are described. Computer control of these experiments using the free-decay technique is outlined. In addition, a pendulum constant-amplitude drive system is described. (auth)

  8. Shielding and filtering techniques to protect sensitive instrumentation from electromagnetic interference caused by arc welding

    International Nuclear Information System (INIS)

    Kalechstein, W.

    1997-01-01

    Electromagnetic interference (EMI) caused by arc welding is a concern for sensitive CANDU instrumentation and control equipment, especially start-up instrumentation (SUI) and ion chamber instruments used to measure neutron flux at low power. Measurements of the effectiveness of simple shielding and filtering techniques that may be applied to limit arc welding electromagnetic emissions below the interference threshold are described. Shielding configurations investigated include an arrangement in which the welding power supply, torch (electrode holder), interconnecting cables and welder operator were housed in a single enclosure and a more practical configuration of separate shields for the power supply, cables and operator with torch. The two configuration were found to provide 30 dB and 26 dB attenuation, respectively, for arc welder electric-field emissions and were successful in preventing EMI in SUI set up just outside the shielding enclosures. Practical improvements that may be incorporated in the shielding arrangement to facilitate quick setup in the field in a variety of application environments, while maintaining adequate EMI protection, are discussed. (author)

  9. Determination of total uranium by mass spectrometry utilizing the isotopic dilution technique

    International Nuclear Information System (INIS)

    Cretella, R.F.; Noutary, C.J.; Servant, R.E.

    1981-01-01

    The isotopic dilution associated to mass spectrometry is a high-sensitivity technique that allows to work with microquantities of the sample, making it possible to analize the content in highly radioactive solutions with excellent accuracy and minimum risk. The proposed technique is described and its results are discussed through the analysis of: 1) A synthetic sample that simulates dissolved spent fuel elements; 2) Uranium dioxide of nuclear purity and 3) Uranium concentrate. 233 U(ORNL) was employed as a tracer and a Nuclide 12-90-SU mass spectrometer of simple magnetic focus as measurement instrument. The accuracy reached in the analyses is better than 0.5% with a reliability of 95%. The analysis of the errors shows that their main contributing source are the errors in the measurement of the isotopic ratios. (M.E.L.) [es

  10. On Representative Spaceflight Instrument and Associated Instrument Sensor Web Framework

    Science.gov (United States)

    Kizhner, Semion; Patel, Umeshkumar; Vootukuru, Meg

    2007-01-01

    Sensor Web-based adaptation and sharing of space flight mission resources, including those of the Space-Ground and Control-User communication segment, could greatly benefit from utilization of heritage Internet Protocols and devices applied for Spaceflight (SpaceIP). This had been successfully demonstrated by a few recent spaceflight experiments. However, while terrestrial applications of Internet protocols are well developed and understood (mostly due to billions of dollars in investments by the military and industry), the spaceflight application of Internet protocols is still in its infancy. Progress in the developments of SpaceIP-enabled instrument components will largely determine the SpaceIP utilization of those investments and acceptance in years to come. Likewise SpaceIP, the development of commercial real-time and instrument colocated computational resources, data compression and storage, can be enabled on-board a spacecraft and, in turn, support a powerful application to Sensor Web-based design of a spaceflight instrument. Sensor Web-enabled reconfiguration and adaptation of structures for hardware resources and information systems will commence application of Field Programmable Arrays (FPGA) and other aerospace programmable logic devices for what this technology was intended. These are a few obvious potential benefits of Sensor Web technologies for spaceflight applications. However, they are still waiting to be explored. This is because there is a need for a new approach to spaceflight instrumentation in order to make these mature sensor web technologies applicable for spaceflight. In this paper we present an approach in developing related and enabling spaceflight instrument-level technologies based on the new concept of a representative spaceflight Instrument Sensor Web (ISW).

  11. Advanced neutron instrumentation at FRM-II

    International Nuclear Information System (INIS)

    Petry, Winfried

    2003-01-01

    The construction of the new German high flux neutron source FRM-II is finished and FRM-II is waiting for its licence to start nuclear operation. With the beginning of the routine operation 22 instruments will be in action, including 5 irradiation facilities and 17 beam tube instruments, most of them use neutron scattering techniques. Additional instruments are under construction. Some of these instruments are unique, others are expected to be the best of their kind, all instruments are based on innovative techniques. (author)

  12. [Evaluation of Medical Instruments Cleaning Effect of Fluorescence Detection Technique].

    Science.gov (United States)

    Sheng, Nan; Shen, Yue; Li, Zhen; Li, Huijuan; Zhou, Chaoqun

    2016-01-01

    To compare the cleaning effect of automatic cleaning machine and manual cleaning on coupling type surgical instruments. A total of 32 cleaned medical instruments were randomly sampled from medical institutions in Putuo District medical institutions disinfection supply center. Hygiena System SUREII ATP was used to monitor the ATP value, and the cleaning effect was evaluated. The surface ATP values of the medical instrument of manual cleaning were higher than that of the automatic cleaning machine. Coupling type surgical instruments has better cleaning effect of automatic cleaning machine before disinfection, the application is recommended.

  13. Achieving a predictable 24-hour return to normal activities after breast augmentation: part II. Patient preparation, refined surgical techniques, and instrumentation.

    Science.gov (United States)

    Tebbetts, John B

    2006-12-01

    The goal of this study was to develop practices that would allow patients undergoing subpectoral augmentation to predictably return to full normal activities within 24 hours after the operation, free of postoperative adjuncts. Part I of this study used motion and time study principles to reduce operative times, medication dosages, perioperative morbidity, and recovery times in augmentation mammaplasty. Part II of the study focuses on details of patient education, preoperative planning, instrumentation, and surgical technique modifications that were identified, modified, and implemented to achieve the results reported in part I. Two groups of 16 patients each (groups 1 and 2) were studied retrospectively for comparison to a third group of 627 patients (group 3) studied prospectively. Patients in group 1 had axillary partial retropectoral breast augmentations in 1982-1983, using dissociative anesthesia, blunt instrument implant pocket dissection, and Dow Corning, double-lumen implants containing 20 mg of methylprednisolone and 20 cc of saline in the outer lumen of the implants. Patients in group 2 (1990) had inframammary, retromammary augmentations by using a combination of blunt and electrocautery dissection, Surgitek Replicon polyurethane-covered, silicone gel-filled implants, and general endotracheal anesthesia. Patients in group 3 (1998 to 2001, n = 627) had inframammary partial retropectoral, inframammary retromammary, and axillary partial retropectoral augmentations under general endotracheal anesthesia. Refined practices and surgical techniques from studies of groups 1 and 2 were applied in group 3. Videotapes from operative procedures of groups 1 and 2 were analyzed with macromotion and micromotion study principles, and tables of events were formulated for each move during the operation for all personnel in the operating room. Extensive details of surgical technique were examined and reexamined in 13 different stages by using principles of motion and time

  14. Utilization technique for advanced nuclear materials database system Data-Free-Way'

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Mitsutane; Kurihara, Yutaka; Kinugawa, Junichi; Kitajima, Masahiro; Nagakawa, Josei; Yamamoto, Norikazu; Noda, Tetsuji; Yagi, Koichi; Ono, Akira [National Research Inst. for Metals, Tsukuba, Ibaraki (Japan)

    2001-02-01

    Four organizations the National Research Institute for Metals (NRIM), the Japan Atomic Energy Research Institute (JAERI), the Japan Nuclear Fuel Cycle Development Institute (JNC) and Japan Science and Technology Incorporation (JST), conducted the 2nd period joint research for the purpose of development of utilization techniques for advanced nuclear materials database system named 'Data-Free-Way' (DFW), to make more useful system to support research and development of the nuclear materials, from FY 1995 to FY 1999. NRIM intended to fill a data system on diffusion and nuclear data by developing utilization technique on diffusion informations of steels and aluminum and nuclear data for materials for its independent system together with participating in fulfil of the DFW. And, NRIM has entered to a project on wide area band circuit application agreed at the G7 by using technologies cultivated by NRIM, to investigate network application technology with the Michigan State University over the sea under cooperation assistant business of JST, to make results on CCT diagram for welding and forecasting of welding heat history accumulated at NRIM for a long term, to perform development of a simulator assisting optimum condition decision of welding. (G.K.)

  15. Developing an instrument to measure emotional behaviour abilities of meaningful learning through the Delphi technique.

    Science.gov (United States)

    Cadorin, Lucia; Bagnasco, Annamaria; Tolotti, Angela; Pagnucci, Nicola; Sasso, Loredana

    2017-09-01

    To identify items for a new instrument that measures emotional behaviour abilities of meaningful learning, according to Fink's Taxonomy. Meaningful learning is an active process that promotes a wider and deeper understanding of concepts. It is the result of an interaction between new and previous knowledge and produces a long-term change of knowledge and skills. To measure meaningful learning capability, it is very important in the education of health professionals to identify problems or special learning needs. For this reason, it is necessary to create valid instruments. A Delphi Study technique was implemented in four phases by means of e-mail. The study was conducted from April-September 2015. An expert panel consisting of ten researchers with experience in Fink's Taxonomy was established to identify the items of the instrument. Data were analysed for conceptual description and item characteristics and attributes were rated. Expert consensus was sought in each of these phases. An 87·5% consensus cut-off was established. After four rounds, consensus was obtained for validation of the content of the instrument 'Assessment of Meaningful learning Behavioural and Emotional Abilities'. This instrument consists of 56 items evaluated on a 6-point Likert-type scale. Foundational Knowledge, Application, Integration, Human Dimension, Caring and Learning How to Learn were the six major categories explored. This content validated tool can help educators (teachers, trainers and tutors) to identify and improve the strategies to support students' learning capability, which could increase their awareness of and/or responsibility in the learning process. © 2017 John Wiley & Sons Ltd.

  16. Utility Assessment of Specificity in Upward Feedback Instruments for Leadership Development

    National Research Council Canada - National Science Library

    Wardak, Theresa

    2003-01-01

    ...) and the other is the recently developed, non-proprietary Upward Feedback Instrument (2002). The Upward Feedback Instrument was designed to measure leadership behaviors at a more specific level...

  17. Instruments to assess stigmatization in dermatology.

    Science.gov (United States)

    Dimitrov, Dimitre; Szepietowski, Jacek C

    2017-11-03

    Stigmatization is the assignment of negative perceptions to an individual because of a perceived difference from the population at large. Skin conditions are frequently the reason of social rejection with a consequent negative influence on the personal and social life of patients. The aim of the current study was to review the available instruments that can be successfully utilized to measure the stigmatization level among dermatological patients. We performed our search on PubMed up to November 2016 and utilized combinations of key phrases containing such words as stigmatization, skin, dermatology, names of various skin conditions (psoriasis, vitiligo, acne, etc.), measurement. The search found a considerable number of articles - 548. After filtering them through a precise selection process, 58 articles remained. We concentrated only on the methodological aspects to assess stigmatization in various dermatoses. The review ascertained that there exist numerous instruments in the form of questionnaires. They were utilized in various researches in order to assess the stigmatization level in patients with skin problems. We divided them into two main groups: dermatology specific instruments (6 questionnaires) and dermatosis/disease specific ones (8 questionnaires). It is recommended to use dermatology-specific instruments to compare the stigmatization level in various skin conditions. They can be utilized as well as a first line tools to study the feeling of stigmatization in specific skin diseases; however, where it is possible, they should be supplemented with the disease-specific instrument for deeper analysis of both qualities of life and stigmatization.

  18. IN VITRO COMPARISON OF GUTTA-PERCHA-FILLED AREA PERCENTAGES IN ROOT CANALS INSTRUMENTED AND OBTURATED WITH DIFFERENT TECHNIQUES*

    Directory of Open Access Journals (Sweden)

    Ayça YILMAZ

    2017-04-01

    Full Text Available Purpose: To evaluate the efficacy of different obturation techniques in root canals instrumented either by hand or rotary instruments with regard to the percentage of gutta- percha-filled area (PGFA. Materials and Methods: One hundred and sixty extracted mandibular premolars with single, straight root canals were studied. Root canals were prepared to an apical size of 30 by hand with a modified crown-down technique or the ProTaper and HEROShaper systems. Teeth were divided into eight groups (n=20 according to the following instrumentation and obturation techniques: G1: Hand files+lateral condensation (LC, G2: Hand files+Thermafil, G3: ProTaper+LC, G4: ProTaper+single-cone, G5: ProTaper+ProTaper-Obturator, G6: HEROShaper+LC, G7: HEROShaper+single-cone, G8: HEROShaper+HEROfill. Horizontal sections were cut at 1, 3, 5, 7, 9, 11 and 13 mm from the apical foramen. A total of 1120 sections obtained were digitally photographed under a stereomicroscope set at 48X magnification. The cross-sectional area of the canal and the gutta-percha was measured by digital image analysis and the PGFA was calculated for each section. Results: The mean of the PGFA in Thermafil (G2, ProTaper-Obturator (G5 and HEROfill (G8 groups was significantly higher than the other groups. In G3 and G4, PGFA showed no significant difference in the apical segments whereas PGFA was significantly higher at the middle and coronal segments in G3. In G6 and G7, PGFA showed no significant difference in the apical and middle segments whereas PGFA was significantly higher at the coronal segments in G6. Conclusion: The carrier-based gutta-percha obturation systems revealed significantly higher PGFA in comparison to single-cone and lateral condensation techniques.

  19. In vitro comparison of gutta-percha-filled area percentages in root canals instrumented and obturated with different techniques.

    Science.gov (United States)

    Yilmaz, Ayca; Karagoz-Kucukay, Isil

    2017-01-01

    To evaluate the efficacy of different obturation techniques in root canals instrumented either by hand or rotary instruments with regard to the percentage of gutta- percha-filled area (PGFA). One hundred and sixty extracted mandibular premolars with single, straight root canals were studied. Root canals were prepared to an apical size of 30 by hand with a modified crown-down technique or the ProTaper and HEROShaper systems. Teeth were divided into eight groups (n=20) according to the following instrumentation and obturation techniques: G1: Hand files+lateral condensation (LC), G2: Hand files+Thermafil, G3: ProTaper+LC, G4: ProTaper+single-cone, G5: ProTaper+ProTaper-Obturator, G6: HEROShaper+LC, G7: HEROShaper+single-cone, G8: HEROShaper+HEROfill. Horizontal sections were cut at 1, 3, 5, 7, 9, 11 and 13 mm from the apical foramen. A total of 1120 sections obtained were digitally photographed under a stereomicroscope set at 48X magnification. The cross-sectional area of the canal and the gutta-percha was measured by digital image analysis and the PGFA was calculated for each section. The mean of the PGFA in Thermafil (G2), ProTaper-Obturator (G5) and HEROfill (G8) groups was significantly higher than the other groups. In G3 and G4, PGFA showed no significant difference in the apical segments whereas PGFA was significantly higher at the middle and coronal segments in G3. In G6 and G7, PGFA showed no significant difference in the apical and middle segments whereas PGFA was significantly higher at the coronal segments in G6. The carrier-based gutta-percha obturation systems revealed significantly higher PGFA in comparison to single-cone and lateral condensation techniques.

  20. Nondestructive evaluation of reinforced plastics by a radiometric measurement technique

    International Nuclear Information System (INIS)

    Entine, Gerald; Afshari, Sia; Verlinden, Matt

    1990-01-01

    The demand for new high-performance plastics has greatly increased with advances in the performance characteristics of sophisticated reinforced engineering resins. However, conventional methods for the evaluation of the glass and filler contents of reinforced plastics are destructive, labor intensive, and time consuming. We have developed a new instrument, to address this problem, which provides for the rapid, accurate, and nondestructive measurement of glass or filler content in reinforced plastics. This instrument utilizes radiation transmission and scattering techniques for analytical measurement of glass, graphite and other fillers used in reinforced plastics. (author)

  1. Commercial Applications of X Ray Spectrometric Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Wegrzynek, D., E-mail: D.Wedgrznek@iaea.org [International Atomic Energy Agency, The IAEA Laboratories, Seibersdorf, Vienna (Austria)

    2013-07-15

    In the 21st century, the X-ray fluorescence (XRF) technique is widely used in process control, industrial applications and for routine elemental analysis. The technique has a multielement capability capable of detecting elements with Z {>=} 10, with a few instruments capable of detecting also elements with Z {>=} 5. It is characterized by a non-destructive analysis process and relatively good detection limits, typically one part per million, for a wide range of elements. The first commercial XRF instruments were introduced to the market about 50 years ago. They were the wavelength dispersive X ray fluorescence (WDXRF) spectrometers utilizing Bragg's law and reflection on crystal lattices for sequential elemental analysis of sample composition. The advances made in radiation detector technology, especially the introduction of semiconductor detectors, improvements in signal processing electronics, availability and exponential growth of personal computer market led to invention of energy dispersive X ray fluorescence (EDXRF) technique. The EDXRF is more cost effective as compared to WDXRF. It also allows for designing compact instruments. Such instruments can be easily tailored to the needs of different customers, integrated with industrial installations, and also miniaturized for the purpose of in-situ applications. The versatility of the technique has been confirmed in a spectacular way by using the XRF and X-ray spectrometric techniques, among few others, during the NASA and ESA missions in search for the evidence of life and presence of water on the surface of Mars. The XRF technique has achieved its strong position within the atomic spectroscopy group of analytical techniques not only due to its versatility but also due to relatively low running costs, as compared to the commonly used methods, e.g., atomic absorption spectrometry (AAS) or inductively coupled plasma atomic emission/mass spectrometry (ICP-AES/MS). Presently, the XRF technique together with X ray

  2. INSTRUMENT FOR EVALUATION OF THE ADAPTED ABILITIES FROM THE ELEMENT OF BASKETBALL TECHNIQUE

    Directory of Open Access Journals (Sweden)

    Goran Šekeljić

    2006-06-01

    Full Text Available The idea of the work is clearly defined, precise and objective instrument for evaluation of the adopted abilities from the elements of basketball technique. The intention is to cut into small fragments the chosen elements of technique which are going to be evaluated with numerical value of every piece itself. The model established in that way is possible to compare with motorical forms acquired by those who are been inquired. Every fragment of motorical form has precise numerical value on which basis is possible to quantify by simple numerical total the obtained level of sports- technical education. We consider possible to diminish the influence of subjectivity such as to form schoolmarks more objectivly by precise and high-quality system of evaluation on the basis of clearly cut into small pieces structures of elements of the complete technique. In that case we could talk about real expert evaluation. The results of the research have shown that the method of evaluation conceived in this way has given excellent metrics characteristics and that, statistically verified, has been more objective than the two other methods predicted in the experiment

  3. Use of elevator instruments when luxating and extracting teeth in dentistry: clinical techniques.

    Science.gov (United States)

    Mamoun, John

    2017-06-01

    In dentistry, elevator instruments are used to luxate teeth, and this technique imparts forces to tooth particles that sever the periodontal ligament around tooth roots inside the socket and expand alveolar bone around tooth particles. These effects can result in extraction of the tooth particles or facilitate systematic forceps extraction of the tooth particles. This article presents basic oral surgery techniques for applying elevators to luxate teeth. Determination of the optimal luxation technique requires understanding of the functions of the straight elevator and the Cryer elevator, the concept of purchase points, how the design elements of elevator working ends and tips influence the functionality of an elevator, application of forces to tooth particles, sectioning teeth at furcations, and bone removal to facilitate luxation. The effectiveness of tooth particle luxation is influenced by elevator tip shape and size, the magnitude and the vectors of forces applied to the tooth particle by the tip, and sectioning and bone removal within the operating field. Controlled extraction procedures are facilitated by a dental operating microscope or the magnification of binocular surgical loupes telescopes, combined with co-axial illumination.

  4. Calibration methodology for instruments utilized in X radiation beams, diagnostic level

    International Nuclear Information System (INIS)

    Penha, M. da; Potiens, A.; Caldas, L.V.E.

    2004-01-01

    Methodologies for the calibration of diagnostic radiology instruments were established at the Calibration Laboratory of IPEN. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. The established qualities are recommended by the international standards IEC 1267 and ISO 4037-3. Two ionization chambers were used as reference systems, one with a volume of 30 cm 3 for radiation protection measurements, and the other with a volume of 1 cm 3 for direct beam measurements. Both are traceable to the German Primary Laboratory of Physikalisch-Technische Bundesanstalt (PTB). In the case of calibration of quality control instruments, a non-invasive method using the measurement of the spectrum endpoint was established with a portable gamma and X-ray Intertechnique spectrometer system. The methods were applied to survey meters (radiation protection measurements), ionization chambers (direct beam measurements) and k Vp meters (invasive and non-invasive instruments). (Author)

  5. Calibration methodology for instruments utilized in X radiation beams, diagnostic level

    Energy Technology Data Exchange (ETDEWEB)

    Penha, M. da; Potiens, A.; Caldas, L.V.E. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear, Sao Paulo (Brazil)]. E-mail: mppalbu@ipen.br

    2004-07-01

    Methodologies for the calibration of diagnostic radiology instruments were established at the Calibration Laboratory of IPEN. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. The established qualities are recommended by the international standards IEC 1267 and ISO 4037-3. Two ionization chambers were used as reference systems, one with a volume of 30 cm{sup 3} for radiation protection measurements, and the other with a volume of 1 cm{sup 3} for direct beam measurements. Both are traceable to the German Primary Laboratory of Physikalisch-Technische Bundesanstalt (PTB). In the case of calibration of quality control instruments, a non-invasive method using the measurement of the spectrum endpoint was established with a portable gamma and X-ray Intertechnique spectrometer system. The methods were applied to survey meters (radiation protection measurements), ionization chambers (direct beam measurements) and k Vp meters (invasive and non-invasive instruments). (Author)

  6. Material control in nuclear fuel fabrication facilities. Part II. Accountability, instrumentation and measurement techniques in fuel fabrication facilities

    International Nuclear Information System (INIS)

    Borgonovi, G.M.; McCartin, T.J.; McDaniel, T.; Miller, C.L.; Nguyen, T.

    1978-01-01

    This report describes the measurement techniques, the instrumentation, and the procedures used in accountability and control of nuclear materials, as they apply to fuel fabrication facilities. A general discussion is given of instrumentation and measurement techniques which are presently used being considered for fuel fabrication facilities. Those aspects which are most significant from the point of view of satisfying regulatory constraints have been emphasized. Sensors and measurement devices have been discussed, together with their interfacing into a computerized system designed to permit real-time data collection and analysis. Estimates of accuracy and precision of measurement techniques have been given, and, where applicable, estimates of associated costs have been presented. A general description of material control and accounting is also included. In this section, the general principles of nuclear material accounting have been reviewed first (closure of material balance). After a discussion of the most current techniques used to calculate the limit of error on inventory difference, a number of advanced statistical techniques are reviewed. The rest of the section deals with some regulatory aspects of data collection and analysis, for accountability purposes, and with the overall effectiveness of accountability in detecting diversion attempts in fuel fabrication facilities. A specific example of application of the accountability methods to a model fuel fabrication facility is given. The effect of random and systematic errors on the total material uncertainty has been discussed, together with the effect on uncertainty of the length of the accounting period

  7. Material control in nuclear fuel fabrication facilities. Part II. Accountability, instrumentation and measurement techniques in fuel fabrication facilities

    Energy Technology Data Exchange (ETDEWEB)

    Borgonovi, G.M.; McCartin, T.J.; McDaniel, T.; Miller, C.L.; Nguyen, T.

    1978-01-01

    This report describes the measurement techniques, the instrumentation, and the procedures used in accountability and control of nuclear materials, as they apply to fuel fabrication facilities. A general discussion is given of instrumentation and measurement techniques which are presently used being considered for fuel fabrication facilities. Those aspects which are most significant from the point of view of satisfying regulatory constraints have been emphasized. Sensors and measurement devices have been discussed, together with their interfacing into a computerized system designed to permit real-time data collection and analysis. Estimates of accuracy and precision of measurement techniques have been given, and, where applicable, estimates of associated costs have been presented. A general description of material control and accounting is also included. In this section, the general principles of nuclear material accounting have been reviewed first (closure of material balance). After a discussion of the most current techniques used to calculate the limit of error on inventory difference, a number of advanced statistical techniques are reviewed. The rest of the section deals with some regulatory aspects of data collection and analysis, for accountability purposes, and with the overall effectiveness of accountability in detecting diversion attempts in fuel fabrication facilities. A specific example of application of the accountability methods to a model fuel fabrication facility is given. The effect of random and systematic errors on the total material uncertainty has been discussed, together with the effect on uncertainty of the length of the accounting period.

  8. An instrument to assess subjective task value beliefs regarding the decision to pursue postgraduate training.

    Science.gov (United States)

    Hagemeier, Nicholas E; Murawski, Matthew M

    2014-02-12

    To develop and validate an instrument to assess subjective ratings of the perceived value of various postgraduate training paths followed using expectancy-value as a theoretical framework; and to explore differences in value beliefs across type of postgraduate training pursued and type of pharmacy training completed prior to postgraduate training. A survey instrument was developed to sample 4 theoretical domains of subjective task value: intrinsic value, attainment value, utility value, and perceived cost. Retrospective self-report methodology was employed to examine respondents' (N=1,148) subjective task value beliefs specific to their highest level of postgraduate training completed. Exploratory and confirmatory factor analytic techniques were used to evaluate and validate value belief constructs. Intrinsic, attainment, utility, cost, and financial value constructs resulted from exploratory factor analysis. Cross-validation resulted in a 26-item instrument that demonstrated good model fit. Differences in value beliefs were noted across type of postgraduate training pursued and pharmacy training characteristics. The Postgraduate Training Value Instrument demonstrated evidence of reliability and construct validity. The survey instrument can be used to assess value beliefs regarding multiple postgraduate training options in pharmacy and potentially inform targeted recruiting of individuals to those paths best matching their own value beliefs.

  9. A guide on instrument of biochemistry and molecular biology

    International Nuclear Information System (INIS)

    1995-10-01

    This book is about instrument on biochemistry and molecular biology, which consists of six chapters. It deals with introduction of advanced bio-instrument, common utilization and maintain, explanation of each instrument like capillary electrophoresis, interactive laser cytometer, personal computer and software, an electron microscope and DNA/RNS synthesis instrument, large equipment and special system like information system and network, analysis system for genome and large spectro graph, outside donation, examples for common utilization and appendix on data like application form for use.

  10. Minimizing Experimental Setup Time and Effort at APS beamline 1-ID through Instrumentation Design

    Energy Technology Data Exchange (ETDEWEB)

    Benda, Erika; Almer, Jonathan; Kenesei, Peter; Mashayekhi, Ali; Okasinksi, John; Park, Jun-Sang; Ranay, Rogelio; Shastri, Sarvijt

    2016-01-01

    Sector 1-ID at the APS accommodates a number of dif-ferent experimental techniques in the same spatial enve-lope of the E-hutch end station. These include high-energy small and wide angle X-ray scattering (SAXS and WAXS), high-energy diffraction microscopy (HEDM, both near and far field modes) and high-energy X-ray tomography. These techniques are frequently combined to allow the users to obtain multimodal data, often attaining 1 μm spatial resolution and <0.05º angular resolution. Furthermore, these techniques are utilized while the sam-ple is thermo-mechanically loaded to mimic real operat-ing conditions. The instrumentation required for each of these techniques and environments has been designed and configured in a modular way with a focus on stability and repeatability between changeovers. This approach allows the end station to be more versatile, capable of collecting multi-modal data in-situ while reducing time and effort typically required for set up and alignment, resulting in more efficient beam time use. Key instrumentation de-sign features and layout of the end station are presented.

  11. Nuclear medicine imaging instrumentations for molecular imaging

    International Nuclear Information System (INIS)

    Chung, Yong Hyun; Song, Tae Yong; Choi, Yong

    2004-01-01

    Small animal models are extensively utilized in the study of biomedical sciences. Current animal experiments and analysis are largely restricted to in vitro measurements and need to sacrifice animals to perform tissue or molecular analysis. This prevents researchers from observing in vivo the natural evolution of the process under study. Imaging techniques can provide repeatedly in vivo anatomic and molecular information noninvasively. Small animal imaging systems have been developed to assess biological process in experimental animals and increasingly employed in the field of molecular imaging studies. This review outlines the current developments in nuclear medicine imaging instrumentations including fused multi-modality imaging systems for small animal imaging

  12. Clinical utility of an automated instrument for gram staining single slides.

    Science.gov (United States)

    Baron, Ellen Jo; Mix, Samantha; Moradi, Wais

    2010-06-01

    Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis.

  13. Postoperative endodontic pain of three different instrumentation techniques in asymptomatic necrotic mandibular molars with periapical lesion: a prospective, randomized, double-blind clinical trial.

    Science.gov (United States)

    Shokraneh, Ali; Ajami, Majid; Farhadi, Nastaran; Hosseini, Mohsen; Rohani, Bita

    2017-01-01

    The purpose of this prospective, randomized, double-blind study was to compare postoperative pain of root canal treatment in patients with asymptomatic mandibular molar teeth with necrotic pulp and periapical lesion using three different instrumentation techniques: hand, multi-file rotary (ProTaper Universal), and reciprocating single-file (Wave-One) instrumentation techniques. Ninety-six patients who fulfilled specific inclusion criteria were assigned to three groups according to the root canal instrumentation technique used: Hand (G1), ProTaper Universal (G2), and Wave-One (G3). One-visit root canal treatment was carried out, and the severity of the postoperative pain was assessed by the Heft-Parker visual analogue scale 6, 12, 18, 24, 48, and 72 h after treatment. Data were analyzed by Kruskal-Wallis, χ 2 , Cochrane Q, one-way ANOVA, and Spearman's correlation analyses (α = 0.05). The patients in group 3 reported significantly lower postoperative pain levels at 6, 12, and 18 h compared with the patients in the two other groups (P  .05). The analgesic consumption was significantly higher in group 1 (P  .05). Postoperative pain was significantly lower in patients undergoing root canal instrumentation with the Wave-One file compared with the ProTaper Universal and hand files.

  14. Digital Signal Processing. A review of DSP formalism, algorithms and networks for the beam instrumentation workshop, Vancouver, Canada, October 4, 1994

    International Nuclear Information System (INIS)

    Linscott, I.

    1995-01-01

    The formalism of Digital Signal Processing (DSP), is reviewed with the objective of providing a framework for understanding the utility of DSP techniques for Beam Instrumentation and developiong criteria for assessing the merits of DSP applications. copyright 1995 American Institute of Physics

  15. ProTaper rotary instrument fracture during root canal preparation: a comparison between rotary and hybrid techniques.

    Science.gov (United States)

    Farid, Huma; Khan, Farhan Raza; Rahman, Munawar

    2013-03-01

    This study aimed to compare the frequency of ProTaper rotary instrument fracture with rotary (conventional) and hybrid (rotary and hand files) canal preparation techniques. Secondary objectives were to determine whether there was an association of ProTaper file fracture with the canal curvature and to compare the mean time required for canal preparation in the two techniques. An in vitro experiment was conducted on 216 buccal canals of extracted maxillary and mandibular first molars. After creating an access cavity and a glide path for each canal, a periapical radiograph was taken and the canal curvature was measured with Schneider's technique. The canals were then randomly divided into Group A (rotary technique) and Group B (hybrid technique). The length of ProTaper files were measured before and after each canal preparation. Time taken for each canal preparation was recorded. A total of seven ProTaper files fractured in Group A (P=0.014) in canals with a curvature >25 degrees (PProTaper rotary files, although time consuming, was safer in canals having a curvature greater than 25 degrees.

  16. On Common Techniques of Music Instrument Perfor-mance and the References%乐器演奏的通用技法和借鉴

    Institute of Scientific and Technical Information of China (English)

    张馨元

    2014-01-01

    The performance techniques of a lot of music instru-ments are extremely similar and interlinked, especially hand styles, fingering, tone tuning, and so on. Therefore, common per-formance techniques of some music instruments were summa-rized to help learners draw inferences from what they've learned, instead of being restricted by the concept of "different instru-ments with different techniques", and in this way they can get more access to the learning of music instrument types with limited energies in limited time. The references to the interlink and and intercommunication of the performance techniques will give im-petus to a better understanding, inheritance, breakthrough and flexible use of the music instruments.%很多乐器的演奏方法都有着极其相似之处,尤其是手型、指法、调音等,相通之处更多。因此,总结出部分乐器演奏的通用技法,让乐器学习者可以举一反三、触类旁通,而不是拘泥于“术业有专攻”的限制,这样就可以在有限的时间内、用有限的精力对乐器种类有更为广泛的接触和学习,从而借鉴演奏方法上的相通之处和相互联系,进一步推动对这些乐器更好地了解、传承、突破及灵活运用。

  17. Astronomical Instrumentation System Markup Language

    Science.gov (United States)

    Goldbaum, Jesse M.

    2016-05-01

    The Astronomical Instrumentation System Markup Language (AISML) is an Extensible Markup Language (XML) based file format for maintaining and exchanging information about astronomical instrumentation. The factors behind the need for an AISML are first discussed followed by the reasons why XML was chosen as the format. Next it's shown how XML also provides the framework for a more precise definition of an astronomical instrument and how these instruments can be combined to form an Astronomical Instrumentation System (AIS). AISML files for several instruments as well as one for a sample AIS are provided. The files demonstrate how AISML can be utilized for various tasks from web page generation and programming interface to instrument maintenance and quality management. The advantages of widespread adoption of AISML are discussed.

  18. Instrumentation for the study of low emittance tuning and beam dynamics at CESR

    Science.gov (United States)

    Billing, M. G.; Dobbins, J. A.; Forster, M. J.; Kreinick, D. L.; Meller, R. E.; Peterson, D. P.; Ramirez, G. A.; Rendina, M. C.; Rider, N. T.; Sagan, D. C.; Shanks, J.; Sikora, J. P.; Stedinger, M. G.; Strohman, C. R.; Williams, H. A.; Palmer, M. A.; Holtzapple, R. L.; Flanagan, J.

    2017-11-01

    The Cornell Electron-positron Storage Ring (CESR) has been converted from a High Energy Physics electron-positron collider to operate as a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS) and to conduct accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Some of the specific topics that were targeted for the initial phase of operation of the storage ring in this mode for CESR as a Test Accelerator (CesrTA) included 1) tuning techniques to produce low emittance beams, 2) the study of electron cloud development in a storage ring and 3) intra-beam scattering effects. The complete conversion of CESR to CesrTA occurred over a several year period, described elsewhere [1-3]. In addition to instrumentation for the storage ring, which was created for CesrTA, existing instrumentation was modified to facilitate the entire range of investigations to support these studies. Procedures were developed, often requiring coordinated measurements among different instruments [4]. This paper describes the instruments utilized for the study of beam dynamics during the operation of CesrTA. The treatment of these instruments will remain fairly general in this paper as it focusses on an overview of the instruments themselves. Their interaction and inter-relationships during sequences of observations is found in a companion paper describing the associated measurement techniques. More detailed descriptions and detailed operational performance for some of the instrumentation may be found elsewhere and these will be referenced in the related sections of this paper.

  19. Thermal Modeling of the Mars Reconnaissance Orbiter's Solar Panel and Instruments during Aerobraking

    Science.gov (United States)

    Dec, John A.; Gasbarre, Joseph F.; Amundsen, Ruth M.

    2007-01-01

    The Mars Reconnaissance Orbiter (MRO) launched on August 12, 2005 and started aerobraking at Mars in March 2006. During the spacecraft s design phase, thermal models of the solar panels and instruments were developed to determine which components would be the most limiting thermally during aerobraking. Having determined the most limiting components, thermal limits in terms of heat rate were established. Advanced thermal modeling techniques were developed utilizing Thermal Desktop and Patran Thermal. Heat transfer coefficients were calculated using a Direct Simulation Monte Carlo technique. Analysis established that the solar panels were the most limiting components during the aerobraking phase of the mission.

  20. Clinical utility of measures of breathlessness.

    Science.gov (United States)

    Cullen, Deborah L; Rodak, Bernadette

    2002-09-01

    The clinical utility of measures of dyspnea has been debated in the health care community. Although breathlessness can be evaluated with various instruments, the most effective dyspnea measurement tool for patients with chronic lung disease or for measuring treatment effectiveness remains uncertain. Understanding the evidence for the validity and reliability of these instruments may provide a basis for appropriate clinical application. Evaluate instruments designed to measure breathlessness, either as single-symptom or multidimensional instruments, based on psychometrics foundations such as validity, reliability, and discriminative and evaluative properties. Classification of each dyspnea measurement instrument will recommend clinical application in terms of exercise, benchmarking patients, activities of daily living, patient outcomes, clinical trials, and responsiveness to treatment. Eleven dyspnea measurement instruments were selected. Each instrument was assessed as discriminative or evaluative and then analyzed as to its psychometric properties and purpose of design. Descriptive data from all studies were described according to their primary patient application (ie, chronic obstructive pulmonary disease, asthma, or other patient populations). The Borg Scale and the Visual Analogue Scale are applicable to exertion and thus can be applied to any cardiopulmonary patient to determine dyspnea. All other measures were determined appropriate for chronic obstructive pulmonary disease, whereas the Shortness of Breath Questionnaire can be applied to cystic fibrosis and lung transplant patients. The most appropriate utility for all instruments was measuring the effects on activities of daily living and for benchmarking patient progress. Instruments that quantify function and health-related quality of life have great utility for documenting outcomes but may be limited as to documenting treatment responsiveness in terms of clinically important changes. The dyspnea

  1. Toward biotechnology in space: High-throughput instruments for in situ biological research beyond Earth.

    Science.gov (United States)

    Karouia, Fathi; Peyvan, Kianoosh; Pohorille, Andrew

    2017-11-15

    Space biotechnology is a nascent field aimed at applying tools of modern biology to advance our goals in space exploration. These advances rely on our ability to exploit in situ high throughput techniques for amplification and sequencing DNA, and measuring levels of RNA transcripts, proteins and metabolites in a cell. These techniques, collectively known as "omics" techniques have already revolutionized terrestrial biology. A number of on-going efforts are aimed at developing instruments to carry out "omics" research in space, in particular on board the International Space Station and small satellites. For space applications these instruments require substantial and creative reengineering that includes automation, miniaturization and ensuring that the device is resistant to conditions in space and works independently of the direction of the gravity vector. Different paths taken to meet these requirements for different "omics" instruments are the subjects of this review. The advantages and disadvantages of these instruments and technological solutions and their level of readiness for deployment in space are discussed. Considering that effects of space environments on terrestrial organisms appear to be global, it is argued that high throughput instruments are essential to advance (1) biomedical and physiological studies to control and reduce space-related stressors on living systems, (2) application of biology to life support and in situ resource utilization, (3) planetary protection, and (4) basic research about the limits on life in space. It is also argued that carrying out measurements in situ provides considerable advantages over the traditional space biology paradigm that relies on post-flight data analysis. Published by Elsevier Inc.

  2. [In vitro comparison of root canal preparation with step-back technique and GT rotary file--a nickel-titanium engine driven rotary instrument system].

    Science.gov (United States)

    Krajczár, Károly; Tóth, Vilmos; Nyárády, Zoltán; Szabó, Gyula

    2005-06-01

    The aim of the authors' study was to compare the remaining root canal wall thickness and the preparation time of root canals, prepared either with step-back technique, or with GT Rotary File, an engine driven nickel-titanium rotary instrument system. Twenty extracted molars were decoronated. Teeth were divided in two groups. In Group 1 root canals were prepared with step-back technique. In Group 2 GT Rotary File System was utilized. Preoperative vestibulo-oral X-ray pictures were taken from all teeth with radiovisiograph (RVG). The final preparations at the mesiobuccal canals (MB) were performed with size #30 and palatinal/distal canals with size #40 instruments. Postoperative RVG pictures were taken ensuring the preoperative positioning. The working time was measured in seconds during each preparation. The authors also assessed the remaining root canal wall thickness at 3, 6 and 9 mm from the radiological apex, comparing the width of the canal walls of the vestibulo-oral projections on pre- and postoperative RVG pictures both mesially and buccally. The ratios of the residual and preoperative root canal wall thickness were calculated and compared. The largest difference was found at the MB canals of the coronal and middle third level of the root, measured on the distal canal wall. The ratio of the remaining dentin wall thickness at the coronal and the middle level in the case of step-back preparation was 0.605 and 0.754, and 0.824 and 0.895 in the cases of GT files respectively. The preparation time needed for GT Rotary File System was altogether 68.7% (MB) and 52.5% (D/P canals) of corresponding step-back preparation times. The use of GT Rotary File with comparison of standard step-back method resulted in a shortened preparation time and excessive damage of the coronal part of the root canal could be avoided.

  3. Identification of the finishing technique of an early eighteenth century musical instrument using FTIR spectromicroscopy.

    Science.gov (United States)

    Bertrand, Loïc; Robinet, Laurianne; Cohen, Serge X; Sandt, Christophe; Le Hô, Anne-Solenn; Soulier, Balthazar; Lattuati-Derieux, Agnès; Echard, Jean-Philippe

    2011-03-01

    The study of varnishes from musical instruments presents the difficulty of analysing very thin layers of heterogeneous materials on samples most of which are generally brittle and difficult to prepare. Such study is crucial to the understanding of historical musical instrument varnishing practices since written sources before 1800 are very rare and not precise. Fourier-transform infrared (FTIR) spectroscopy and imaging methods were applied to identify the major chemical components within the build-up of the varnish layers on a cello made by one of the most prominent French violin-makers of the eighteenth century (Jacques Boquay, ca. 1680-1730). Two types of FTIR imaging methods were used: scanning with a synchrotron-based microscope and full-field imaging using a 2D imager with a conventional source. An interpretation of the results obtained from these studies on the Boquay cello is that the maker first applied a proteinaceous layer, probably gelatine-based animal glue. He later applied a second layer based on a mixture of a drying oil and diterpenic resin from Pinaceae sp. From an historical perspective, the results complement previous studies by describing a second technique used for musical instrument finishes at the beginning of the eighteenth century in Europe.

  4. Commercial Applications of X Ray Spectrometric Techniques

    International Nuclear Information System (INIS)

    Wegrzynek, D.

    2013-01-01

    In the 21st century, the X-ray fluorescence (XRF) technique is widely used in process control, industrial applications and for routine elemental analysis. The technique has a multielement capability capable of detecting elements with Z ≥ 10, with a few instruments capable of detecting also elements with Z ≥ 5. It is characterized by a non-destructive analysis process and relatively good detection limits, typically one part per million, for a wide range of elements. The first commercial XRF instruments were introduced to the market about 50 years ago. They were the wavelength dispersive X ray fluorescence (WDXRF) spectrometers utilizing Bragg’s law and reflection on crystal lattices for sequential elemental analysis of sample composition. The advances made in radiation detector technology, especially the introduction of semiconductor detectors, improvements in signal processing electronics, availability and exponential growth of personal computer market led to invention of energy dispersive X ray fluorescence (EDXRF) technique. The EDXRF is more cost effective as compared to WDXRF. It also allows for designing compact instruments. Such instruments can be easily tailored to the needs of different customers, integrated with industrial installations, and also miniaturized for the purpose of in-situ applications. The versatility of the technique has been confirmed in a spectacular way by using the XRF and X-ray spectrometric techniques, among few others, during the NASA and ESA missions in search for the evidence of life and presence of water on the surface of Mars. The XRF technique has achieved its strong position within the atomic spectroscopy group of analytical techniques not only due to its versatility but also due to relatively low running costs, as compared to the commonly used methods, e.g., atomic absorption spectrometry (AAS) or inductively coupled plasma atomic emission/mass spectrometry (ICP-AES/MS). Presently, the XRF technique together with X ray

  5. Current practice and feasibility in microlaryngeal surgery: microsurgical pressing excision technique.

    Science.gov (United States)

    Lee, Ka-Wo; Chiang, Feng-Yu

    2009-12-01

    Since the introduction of endolaryngeal microsurgery, several basic microsurgical techniques have been described for the removal of benign vocal fold lesions. These techniques include conventional incision or dissection, bimanual retraction and cutting, microflap technique and the CO2 laser. Until recently, only a few microsurgical methods have emerged as new choices for the treatment of benign vocal fold lesions. This article introduces an innovative method that can precisely remove benign sessile vocal fold lesions with epithelial keratosis or hyperplasia without jeopardizing the intermediate or deep layer of the lamina propria. Instead of using conventional vertically opening microinstruments, this microsurgical pressing excision technique (MPET) utilized two pairs of custom-made horizontally left-opening or right-opening, curved microscissors/curved cupped microforceps to remove right or left vocal fold lesions accordingly. Using one instrument at a time, the lesion was subsequently removed with the microscissors and microforceps in a press-evert-cut manner. Among a total of 553 cases, the treatment results were satisfactory, with 520 (94%) patients retaining a satisfactory/normal (G0) voice 2 months postoperatively. More importantly, no patient's voice was worse postoperatively. This technique has several advantages: utilizing one instrument at a time can maximize exposure of the narrow endoscopic view, adjusting the pressing force makes precise excision easy in a well controlled horizontal plane. The MPET is particularly useful for removing sessile vocal nodules (especially those with epithelial keratosis), epithelial hyperplasia and leukoplakia in patients with difficult endolaryngeal exposure. This could be a well tolerated and precise microsurgical technique.

  6. An improved instrument setpoint control program

    International Nuclear Information System (INIS)

    Cash, J.S. Jr.; George, R.T.; Kincaid, S.C.

    1991-01-01

    Instrument setpoints have a definite and often significant impact on plant safety, reliability, and availability. Although typically overshadowed by plant design, modification, and physical change activities, instrument setpoints can alter plant status and system operating characteristics just as significantly. Recognizing the need for a formal program that provides configuration control of instrument setpoints, provides a readily accessible and clearly documented basis for instrument setpoints, and integrates and coordinates operations, engineering, and maintenance activities that influence the basis for instrument setpoints, Philadelphia Electric Company (PECo) is developing an Improved Instrument Setpoint Control Program (IISCP) that incorporates current industry guidance and practices and state-of-the-art information systems technology. The IISCP was designed around PECo's then existing business processes for setpoint control, determination, and maintenance. A task force representing the various constituencies from both plants and the engineering and services organizations were formed to identify objectives and design features for the IISCP. Utilizing industry standards and guidance, regulatory documents, the experiences and good practices obtained from other utilities, and PECo's nuclear group strategies, objectives, and goals, specific objectives were identified to enhance the business processes

  7. Canal preparation with nickel-titanium or stainless steel instruments without the risk of instrument fracture: preliminary observations

    OpenAIRE

    Ghassan Yared

    2015-01-01

    This report introduces a novel technique that allows a safe and predictable canal negotiation, creation of a glide path and canal preparation with reciprocating nickel-titanium or stainless steel engine-driven instruments in canals where the use of rotary and the newly developed reciprocating instruments is contraindicated. In this novel technique, the instruments are used in reciprocating motion with very small angles. Hand files are not used regardless of the complexity of the canal anatomy...

  8. A technical study of alloy compositions of "brass" wind musical instruments (1651-1867) utilizing non-destructive X-ray fluorescence

    Science.gov (United States)

    Bacon, Alice Louise

    This thesis represents a new interdisciplinary approach to the conservation, care and curatorial study of 'brass' wind musical instruments. It attempts to combine metallurgical, chronological and historical aspects for a selection of instruments. The research consists of the systematic study of seventy-seven musical instruments, by known makers, using standardised non-destructive energy dispersive x-ray fluorescence (XRF). Such compositional data are virtually non-existent for historical 'brass' instruments in Britain and what few technical data that do exist are sporadic in quantity and quality. The development of brass instruments is interwoven with the history of brass making, but because there are a limited number of appropriate examples such links can be difficult to identify. This thesis describes the development of brass production from the cementation process to the commercial production of zinc and modern brass. Its relationship to the musical instrument industry in Britain is linked with historical evidence. It will be shown that innovation and known historical metallurgical achievements are reflected in the compositional changes of the alloys used for musical instruments. This thesis focuses on specific named brass wind musical instrument makers. This thesis sets out to investigate the extent to which a single analytical technique such as non-destructive analysis utilising XRF could be useful in the curatorial and conservation care of musical instruments. The results of the analyses revealed new aspects to the use of metals for making musical instruments. They give new information on approximate alloy compositions and, in particular, the results have shown that in the seventeenth-century in England, a ternary alloy of copper/tin/zinc was used, and that it was, perhaps, only superseded by brass (copper/zinc alloy) in the eighteenth century. It has been possible to arrange the results into a chronology of alloys particularly reflecting the change from the

  9. Analytical techniques for wine analysis: An African perspective; a review

    International Nuclear Information System (INIS)

    Villiers, André de; Alberts, Phillipus; Tredoux, Andreas G.J.; Nieuwoudt, Hélène H.

    2012-01-01

    Highlights: ► Analytical techniques developed for grape and wine analysis in Africa are reviewed. ► The utility of infrared spectroscopic methods is demonstrated. ► An overview of separation of wine constituents by GC, HPLC, CE is presented. ► Novel LC and GC sample preparation methods for LC and GC are presented. ► Emerging methods for grape and wine analysis in Africa are discussed. - Abstract: Analytical chemistry is playing an ever-increasingly important role in the global wine industry. Chemical analysis of wine is essential in ensuring product safety and conformity to regulatory laws governing the international market, as well as understanding the fundamental aspects of grape and wine production to improve manufacturing processes. Within this field, advanced instrumental analysis methods have been exploited more extensively in recent years. Important advances in instrumental analytical techniques have also found application in the wine industry. This review aims to highlight the most important developments in the field of instrumental wine and grape analysis in the African context. The focus of this overview is specifically on the application of advanced instrumental techniques, including spectroscopic and chromatographic methods. Recent developments in wine and grape analysis and their application in the African context are highlighted, and future trends are discussed in terms of their potential contribution to the industry.

  10. Analytical techniques for wine analysis: An African perspective; a review

    Energy Technology Data Exchange (ETDEWEB)

    Villiers, Andre de, E-mail: ajdevill@sun.ac.za [Department of Chemistry and Polymer Science, Stellenbosch University, Private Bag X1, Matieland 7602, Stellenbosch (South Africa); Alberts, Phillipus [Department of Chemistry and Polymer Science, Stellenbosch University, Private Bag X1, Matieland 7602, Stellenbosch (South Africa); Tredoux, Andreas G.J.; Nieuwoudt, Helene H. [Institute for Wine Biotechnology, Department of Viticulture and Oenology, Stellenbosch University, Private Bag X1, Matieland 7602, Stellenbosch (South Africa)

    2012-06-12

    Highlights: Black-Right-Pointing-Pointer Analytical techniques developed for grape and wine analysis in Africa are reviewed. Black-Right-Pointing-Pointer The utility of infrared spectroscopic methods is demonstrated. Black-Right-Pointing-Pointer An overview of separation of wine constituents by GC, HPLC, CE is presented. Black-Right-Pointing-Pointer Novel LC and GC sample preparation methods for LC and GC are presented. Black-Right-Pointing-Pointer Emerging methods for grape and wine analysis in Africa are discussed. - Abstract: Analytical chemistry is playing an ever-increasingly important role in the global wine industry. Chemical analysis of wine is essential in ensuring product safety and conformity to regulatory laws governing the international market, as well as understanding the fundamental aspects of grape and wine production to improve manufacturing processes. Within this field, advanced instrumental analysis methods have been exploited more extensively in recent years. Important advances in instrumental analytical techniques have also found application in the wine industry. This review aims to highlight the most important developments in the field of instrumental wine and grape analysis in the African context. The focus of this overview is specifically on the application of advanced instrumental techniques, including spectroscopic and chromatographic methods. Recent developments in wine and grape analysis and their application in the African context are highlighted, and future trends are discussed in terms of their potential contribution to the industry.

  11. Instruments

    International Nuclear Information System (INIS)

    Buehrer, W.

    1996-01-01

    The present paper mediates a basic knowledge of the most commonly used experimental techniques. We discuss the principles and concepts necessary to understand what one is doing if one performs an experiment on a certain instrument. (author) 29 figs., 1 tab., refs

  12. 3D Analysis of D-RaCe and Self-Adjusting File in Removing Filling Materials from Curved Root Canals Instrumented and Filled with Different Techniques

    Directory of Open Access Journals (Sweden)

    Neslihan Simsek

    2014-01-01

    Full Text Available The aim of this study was to compare the efficacy of D-RaCe files and a self-adjusting file (SAF system in removing filling material from curved root canals instrumented and filled with different techniques by using microcomputed tomography (micro-CT. The mesial roots of 20 extracted mandibular first molars were used. Root canals (mesiobuccal and mesiolingual were instrumented with SAF or Revo-S. The canals were then filled with gutta-percha and AH Plus sealer using cold lateral compaction or thermoplasticized injectable techniques. The root fillings were first removed with D-RaCe (Step 1, followed by Step 2, in which a SAF system was used to remove the residual fillings in all groups. Micro-CT scans were used to measure the volume of residual filling after root canal filling, reinstrumentation with D-RaCe (Step 1, and reinstrumentation with SAF (Step 2. Data were analyzed using Wilcoxon and Kruskal-Wallis tests. There were no statistically significant differences between filling techniques in the canals instrumented with SAF (P=0.292 and Revo-S (P=0.306. The amount of remaining filling material was similar in all groups (P=0.363; all of the instrumentation techniques left filling residue inside the canals. However, the additional use of SAF was more effective than using D-RaCe alone.

  13. Canal preparation with nickel-titanium or stainless steel instruments without the risk of instrument fracture: preliminary observations

    Directory of Open Access Journals (Sweden)

    Ghassan Yared

    2015-02-01

    Full Text Available This report introduces a novel technique that allows a safe and predictable canal negotiation, creation of a glide path and canal preparation with reciprocating nickel-titanium or stainless steel engine-driven instruments in canals where the use of rotary and the newly developed reciprocating instruments is contraindicated. In this novel technique, the instruments are used in reciprocating motion with very small angles. Hand files are not used regardless of the complexity of the canal anatomy. It also allows achieving predictable results in canal negotiation and glide path creation in challenging canals without the risk of instrument fracture.

  14. Instrumental Effects of Fiscal Policy for Pakistan Economy

    Directory of Open Access Journals (Sweden)

    Ghulam Rasool Madni

    2013-12-01

    Full Text Available Fiscal policy has much controversial debate regarding its effectiveness on economic growth. Taxation and government expenditure are two main instruments of fiscal policy. This paper is aimed to analyze the effect of different categories of government expenditure on economic growth of Pakistan. Based on impact on economic growth, government expenditures are classified into productive (having positive or neutral effect on economic growth and unproductive expenditures (having negative or insignificant impact on economic growth. The data time span for this study is 1979-2012. After classification of expenditures, the impact of fiscal instruments is analyzed by utilizing the ARDL approach of Co integration which is a better estimation technique for small sample size. The results reveal that unproductive government expenditure have negative impact while productive government expenditure has insignificant impact on the economic growth. It is found that private investment positively and significantly affect the economic growth. On the other side, direct and indirect taxes have also insignificant impact on economic growth of Pakistan

  15. Calibration through on-line monitoring of instruments channels

    International Nuclear Information System (INIS)

    James, R.W.

    1996-01-01

    Plant technical specifications require periodic calibration of instrument channels, and this has traditionally meant calibration at fixed time intervals for nearly all instruments. Experience has shown that unnecessarily frequent calibrations reduce channel availability and reliability, impact outage durations, and increase maintenance costs. An alternative approach to satisfying existing requirements for periodic calibration consists of on-line monitoring and quantitative comparison of instrument channels during operation to identify instrument degradation and failure. A Utility Working Group has been formed by EPRI to support the technical activities necessary to achieve generic NRC acceptance of on-line monitoring of redundant instrument channels as a basis for determining when to perform calibrations. A topical report proposing NRC acceptance of this approach was submitted in August 1995, and the Working Group is currently resolving NRC technical questions. This paper describes the proposed approach and the current status of the topical report with regard to NRC review. While these activities will not preclude utilities from continuing to use existing calibration approaches, successful acceptance of this performance-based approach will allow utilities to substantially reduce the number of calibrations which are performed. Concurrent benefits will include reduced I ampersand C impact on outage durations and improved sensitivity to instrument channel performance

  16. Techniques of analyzing the impacts of certain electric-utility ratemaking and regulatory-policy concepts. Bibliography

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-08-01

    This bibliography provides documentation for use by state public utility commissions and major nonregulated utilities in evaluating the applicability of a wide range of electric utility rate design and regulatory concepts in light of certain regulatory objectives. Part I, Utility Regulatory Objectives, contains 2084 citations on conservation of energy and capital; efficient use of facilities and resources; and equitable rates to electricity consumers. Part II, Rate Design Concepts, contains 1238 citations on time-of-day rates; seasonally-varying rates; cost-of-service rates; interruptible rates (including the accompanying use of load management techniques); declining block rates; and lifeline rates. Part III, Regulatory Concepts, contains 1282 references on restrictions on master metering; procedures for review of automatic adjustment clauses; prohibitions of rate or regulatory discrimination against solar, wind, or other small energy systems; treatment of advertising expenses; and procedures to protect ratepayers from abrupt termination of service.

  17. Design of and initial results from a Highly Instrumented Reactor for Atmospheric Chemistry (HIRAC

    Directory of Open Access Journals (Sweden)

    D. R. Glowacki

    2007-10-01

    Full Text Available The design of a Highly Instrumented Reactor for Atmospheric Chemistry (HIRAC is described and initial results obtained from HIRAC are presented. The ability of HIRAC to perform in-situ laser-induced fluorescence detection of OH and HO2 radicals with the Fluorescence Assay by Gas Expansion (FAGE technique establishes it as internationally unique for a chamber of its size and pressure/temperature variable capabilities. In addition to the FAGE technique, HIRAC features a suite of analytical instrumentation, including: a multipass FTIR system; a conventional gas chromatography (GC instrument and a GC instrument for formaldehyde detection; NO/NO2, CO, O3, and H2O vapour analysers. Ray tracing simulations and NO2 actinometry have been utilized to develop a detailed model of the radiation field within HIRAC. Comparisons between the analysers and the FTIR coupled to HIRAC have been performed, and HIRAC has also been used to investigate pressure dependent kinetics of the chlorine atom reaction with ethene and the reaction of O3 and t-2-butene. The results obtained are in good agreement with literature recommendations and Master Chemical Mechanism predictions. HIRAC thereby offers a highly instrumented platform with the potential for: (1 high precision kinetics investigations over a range of atmospheric conditions; (2 detailed mechanism development, significantly enhanced according to its capability for measuring radicals; and (3 field instrument intercomparison, calibration, development, and investigations of instrument response at a range of atmospheric conditions.

  18. Proceedings of recent innovations and experience with plant monitoring and utility operations

    International Nuclear Information System (INIS)

    Fruchtman, I.

    1991-01-01

    This book contains proceedings of Recent Innovations and Experience with Plant Monitoring and Utility Operations. Topics covered include: a number of innovative actions recently applied at plants in the United States, Australia, and the People's Republic of China. A preview of forthcoming instrumentation and monitoring techniques, enhanced boiler and turbine operations and maintenance, determining root causes of boiler related problems, welding technique that eliminates high temperature, post weld heat treatment, successful application of a portable oil filtration skid, and a method of evaluation for high pressure turbine life assessment using the EPRI rotor life assessment software

  19. The Coherent X-ray Imaging (CXI) Instrument at the Linac Coherent Light Source (LCLS)

    International Nuclear Information System (INIS)

    Boutet, Sebastien

    2011-01-01

    The Linac Coherent Light Source (LCLS) has become the first ever operational hard X-ray Free Electron Laser in 2009. It will operate as a user facility capable of delivering unique research opportunities in multiple fields of science. The LCLS and the LCLS Ultrafast Science Instruments (LUSI) construction projects are developing instruments designed to make full use of the capabilities afforded by the LCLS beam. One such instrument is being designed to utilize the LCLS coherent beam to image with high resolution any sub-micron object. This instrument is called the Coherent X-ray Imaging (CXI) instrument. This instrument will provide a flexible optical system capable of tailoring key beam parameters for the users. A suite of shot-to-shot diagnostics will also be provided to characterize the beam on every pulse. The provided instrumentation will include multi-purpose sample environments, sample delivery and a custom detector capable of collecting 2D data at 120 Hz. In this article, the LCLS will be briefly introduced along with the technique of Coherent X-ray Diffractive Imaging (CXDI). A few examples of scientific opportunities using the CXI instrument will be described. Finally, the conceptual layout of the instrument will be presented along with a description of the key requirements for the overall system and specific devices required.

  20. Update on Instrumentations for Cholecystectomies Performed via Transvaginal Route: State of the Art and Future Prospectives

    Directory of Open Access Journals (Sweden)

    Elia Pulvirenti

    2010-01-01

    Full Text Available Natural Orifice Transluminal Endoscopic Surgery (NOTES is an innovative approach in which a flexible endoscope enters the abdominal cavity via the transesophageal, transgastric, transcolonic, transvaginal or transvescical route, combining the technique of minimally invasive surgery with flexible endoscopy. Several groups have described different modifications by using flexible endoscopes with different levels of laparoscopic assistance. Transvaginal cholecystectomy (TVC consists in accessing the abdominal cavity through a posterior colpotomy and using the vaginal incision as a visual or operative port. An increasing interest has arisen around the TVC; nevertheless, the most common and highlighted concern is about the lack of specific instruments dedicated to the vaginal access route. TVC should be distinguished between “pure”, in which the entire operation is performed through the transvaginal route, and “hybrid”, in which the colpotomy represents only a support to introduce instruments and the operation is performed mainly by the classic transabdominal-introduced instruments. Although this new technique seems very appealing for patients, on the other hand it is very challenging for the surgeon because of the difficulties related to the mode of access, the limited technology currently available and the risk of complications related to the organ utilized for access. In this brief review all the most recent advancements in the field of TVC's techniques and instrumentations are listed and discussed.

  1. Instrumental development and data processing

    International Nuclear Information System (INIS)

    Franzen, J.

    1978-01-01

    A review of recent developments in mass spectrometry instrumentation is presented under the following headings: introduction (scope of mass spectrometry compared with neighbouring fields); ion sources and ionization techniques; spectrometers (instrumental developments); measuring procedures; coupling techniques; data systems; conclusions (that mass spectrometry should have a broader basis and that there would be mutual profit from a better penetration of mass spectrometry into fields of routine application). (U.K.)

  2. Instrumentation for environmental monitoring: biomedical

    International Nuclear Information System (INIS)

    1979-05-01

    An update is presented to Volume four of the six-volume series devoted to a survey of instruments useful for measurements in biomedicine related to environmental research and monitoring. Results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Methods of detection and analysis of gaseous organic pollutants and metals, including Ni and As are presented. Instrument techniques and notes are included on atomic spectrometry and uv and visible absorption instrumentation

  3. Non-process instrumentation surveillance and test reduction

    International Nuclear Information System (INIS)

    Ferrell, R.; LeDonne, V.; Donat, T.; Thomson, I.; Sarlitto, M.

    1993-12-01

    Analysis of operating experience, instrument failure modes, and degraded instrument performance has led to a reduction in Technical Specification surveillance and test requirements for nuclear power plant process instrumentation. These changes have resulted in lower plant operations and maintenance (O ampersand M) labor costs. This report explores the possibility of realizing similar savings by reducing requirements for non-process instrumentation. The project team reviewed generic Technical Specifications for the four major US nuclear steam supply system (NSSS) vendors (Westinghouse, General Electric, Combustion Engineering, and Babcock ampersand Wilcox) to identify nonprocess instrumentation for which surveillance/test requirements could be reduced. The team surveyed 10 utilities to identify specific non-process instrumentation at their plants for which requirements could be reduced. The team evaluated utility analytic approaches used to justify changes in surveillance/test requirements for process equipment to determine their applicability to non-process instrumentation. The report presents a prioritized list of non-process instrumentation systems suitable for surveillance/test requirements reduction. The top three systems in the list are vibration monitors, leak detection monitors, and chemistry monitors. In general, most non-process instrumentation governed by Technical Specification requirements are candidates for requirements reduction. If statistical requirements are somewhat relaxed, the analytic approaches previously used to reduce requirements for process instrumentation can be applied to non-process instrumentation. The report identifies as viable the technical approaches developed and successfully used by Southern California Edison, Arizona Public Service, and Boston Edison

  4. VIRUS instrument enclosures

    Science.gov (United States)

    Prochaska, T.; Allen, R.; Mondrik, N.; Rheault, J. P.; Sauseda, M.; Boster, E.; James, M.; Rodriguez-Patino, M.; Torres, G.; Ham, J.; Cook, E.; Baker, D.; DePoy, Darren L.; Marshall, Jennifer L.; Hill, G. J.; Perry, D.; Savage, R. D.; Good, J. M.; Vattiat, Brian L.

    2014-08-01

    The Visible Integral-Field Replicable Unit Spectrograph (VIRUS) instrument will be installed at the Hobby-Eberly Telescope† in the near future. The instrument will be housed in two enclosures that are mounted adjacent to the telescope, via the VIRUS Support Structure (VSS). We have designed the enclosures to support and protect the instrument, to enable servicing of the instrument, and to cool the instrument appropriately while not adversely affecting the dome environment. The system uses simple HVAC air handling techniques in conjunction with thermoelectric and standard glycol heat exchangers to provide efficient heat removal. The enclosures also provide power and data transfer to and from each VIRUS unit, liquid nitrogen cooling to the detectors, and environmental monitoring of the instrument and dome environments. In this paper, we describe the design and fabrication of the VIRUS enclosures and their subsystems.

  5. Compact and Light-Weight Solar Spaceflight Instrument Designs Utilizing Newly Developed Miniature Free-Standing Zone Plates: EUV Radiometer and Limb-Scanning Monochromator

    Science.gov (United States)

    Seely, J. F.; McMullin, D. R.; Bremer, J.; Chang, C.; Sakdinawat, A.; Jones, A. R.; Vest, R.

    2014-12-01

    Two solar instrument designs are presented that utilize newly developed miniature free-standing zone plates having interconnected Au opaque bars and no support membrane resulting in excellent long-term stability in space. Both instruments are based on a zone plate having 4 mm outer diameter and 1 to 2 degree field of view. The zone plate collects EUV radiation and focuses a narrow bandpass through a pinhole aperture and onto a silicon photodiode detector. As a miniature radiometer, EUV irradiance is accurately determined from the zone plate efficiency and the photodiode responsivity that are calibrated at the NIST SURF synchrotron facility. The EUV radiometer is pointed to the Sun and measures the absolute solar EUV irradiance in high time cadence suitable for solar physics and space weather applications. As a limb-scanning instrument in low earth orbit, a miniature zone-plate monochromator measures the extinction of solar EUV radiation by scattering through the upper atmosphere which is a measure of the variability of the ionosphere. Both instruments are compact and light-weight and are attractive for CubeSats and other missions where resources are extremely limited.

  6. Instruments for radiation measurement in biosciences. Series 3. radioluminography. 1. Results of questionnaires to the scientists using radioluminographic techniques

    International Nuclear Information System (INIS)

    Kurihara, Norio; Nakajima, Eiichi; Takahashi, Sentaro

    1998-01-01

    Radioluminography (RLG) is a method to detect radioactivity with its photostimulated luminescence phenomenon. This paper describes major results of questionnaires to the scientists using RLG technique which was performed by the technical subcommittee for research instruments for isotope tracer of Life Science Section, Japan Radioisotope Association. The main purpose was to find the advantage and problems of RLG recognized by users. Questionnaires were sent to 271 users and 101 answers were obtained from pharmaceutical companies, universities and other public research facilities. RLG was found mainly used in gel electrophoresis in the molecular biology field, thin layer chromatography and quantitative whole body autoradiography. RLG technology itself of the instrument, imaging plate and standard usage was found to be in progress as well. Problems were those on the fundamental handling (e.g., ROI definition), on instruments, on quantitativeness, on different nuclides, on value for formal data and on radiation control. The major instrument manufacturers were Fuji Film Co., BioRad Co. and Molecular Dynamics Co. Results of the questionnaire will be published in more detailed form in future. (K.H.)

  7. [Clinical Application of Analytical and Medical Instruments Mainly Using MS Techniques].

    Science.gov (United States)

    Tanaka, Koichi

    2016-02-01

    Analytical instruments for clinical use are commonly required to confirm the compounds and forms related to diseases with the highest possible sensitivity, quantitative performance, and specificity and minimal invasiveness within a short time, easily, and at a low cost. Advancements of technical innovation for Mass Spectrometer (MS) have led to techniques that meet such requirements. Besides confirming known substances, other purposes and advantages of MS that are not fully known to the public are using MS as a tool to discover unknown phenomena and compounds. An example is clarifying the mechanisms of human diseases. The human body has approximately 100 thousand types of protein, and there may be more than several million types of protein and their metabolites. Most of them have yet to be discovered, and their discovery may give birth to new academic fields and lead to the clarification of diseases, development of new medicines, etc. For example, using the MS system developed under "Contribution to drug discovery and diagnosis by next generation of advanced mass spectrometry system," one of the 30 projects of the "Funding Program for World-Leading Innovative R&D on Science and Technology" (FIRST program), and other individual basic technologies, we succeeded in discovering new disease biomarker candidates for Alzheimer's disease, cancer, etc. Further contribution of MS to clinical medicine can be expected through the development and improvement of new techniques, efforts to verify discoveries, and communications with the medical front.

  8. Instruments and techniques of undispersion X-ray spectral analysis for nickel in case of high iron contents

    International Nuclear Information System (INIS)

    Betin, Yu.P.; Zhabin, E.G.; Komov, A.P.; Krampit, I.A.; Novikov, A.M.; Serkin, V.P.; Smirnov, V.N.; Chernov, A.I.

    1979-01-01

    Considered is one of the most complicated problems of dispersionless X-ray spectral analysis (DXRSA) for low concentrations of the element with Z+2 atomic number in presence of large contents of element with Z atomic number (from manganese to zinc) in conformity with the DXRSA. The problem is solved with the help of instruments with two-channel registration system including a selection filter, target-converter and proportional counter at excitation of secondary radiation with X-ray tube. At the developed methodics an absolute mean square error of reproduction does not exceed 0.01%, the deviation of DXRSA results on results of control analysis for slags of nickel production - not more than 0.02-0.03%. The introduction of instruments and technique has given the economic effect of 32 thousand rubles

  9. Clinical Utility of an Automated Instrument for Gram Staining Single Slides ▿

    Science.gov (United States)

    Baron, Ellen Jo; Mix, Samantha; Moradi, Wais

    2010-01-01

    Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis. PMID:20410348

  10. Comparison of the remaining dentin thickness in the root after hand and four rotary instrumentation techniques: an in vitro study.

    Science.gov (United States)

    Rao, M S Rama; Shameem, Abdul; Nair, Rashmi; Ghanta, Sureshbabu; Thankachan, Rekha P; Issac, Johnson K

    2013-07-01

    The aim of the present study was to compare the remaining dental thickness (RDT) in the mesiobuccal root of mandibular first molars at 3 and 7 mm from the anatomic apex after instrumentation with ProTaper, light speed LSX, K3 and M2 and to compare with that of K-files. In this study, 60 extracted, untreated human mandibular first molars with fully formed apices, with curvature less than 35° and no root resorption were used. Prepared specimens were cut horizontally at 3 and 7 mm short of anatomic apex. The least dentin thickness from canal to external root surface was observed under 3× magnification and recorded using Clemax measuring tool and the sections were reassembled. Group I-instrumentation with ProTaper, group II-instrumentation with K3, group III-instrumentation with Light Speed LSX, group IV-instrumentation with M2 and group V- instrumentation with K-files and RDT was measured. Results showed that group V removed lesser amount of dentin compared to all other groups while all the three instrumentation techniques removed almost equal amount of dentin apically. Cleaning and shaping of the root canal space involves the elimination of pathogenic contents as well as attaining a uniform specific shape. However, the RDT following the use of various intraradicular procedures is an important factor to be considered as an iatrogenic cause that may result in root fracture. To avoid this, newer rotary instruments are being introduced.

  11. Development of indigenous technology at CNEN in the fields of nuclear medicine, nuclear detectors, instrumentation, radioisotope production and application of nuclear techniques

    International Nuclear Information System (INIS)

    Mafra, O.

    1990-01-01

    The main objectives of the program developed at CNEN in the field of nuclear medicine, nuclear detectors, instrumentation, radioisotope production and application of nuclear technique are described. (E.G.) [pt

  12. Instrument Remote Control via the Astronomical Instrument Markup Language

    Science.gov (United States)

    Sall, Ken; Ames, Troy; Warsaw, Craig; Koons, Lisa; Shafer, Richard

    1998-01-01

    The Instrument Remote Control (IRC) project ongoing at NASA's Goddard Space Flight Center's (GSFC) Information Systems Center (ISC) supports NASA's mission by defining an adaptive intranet-based framework that provides robust interactive and distributed control and monitoring of remote instruments. An astronomical IRC architecture that combines the platform-independent processing capabilities of Java with the power of Extensible Markup Language (XML) to express hierarchical data in an equally platform-independent, as well as human readable manner, has been developed. This architecture is implemented using a variety of XML support tools and Application Programming Interfaces (API) written in Java. IRC will enable trusted astronomers from around the world to easily access infrared instruments (e.g., telescopes, cameras, and spectrometers) located in remote, inhospitable environments, such as the South Pole, a high Chilean mountaintop, or an airborne observatory aboard a Boeing 747. Using IRC's frameworks, an astronomer or other scientist can easily define the type of onboard instrument, control the instrument remotely, and return monitoring data all through the intranet. The Astronomical Instrument Markup Language (AIML) is the first implementation of the more general Instrument Markup Language (IML). The key aspects of our approach to instrument description and control applies to many domains, from medical instruments to machine assembly lines. The concepts behind AIML apply equally well to the description and control of instruments in general. IRC enables us to apply our techniques to several instruments, preferably from different observatories.

  13. Evalution of NDA techniques and instruments for assay of nuclear waste at a waste terminal storage facility

    International Nuclear Information System (INIS)

    Blakeman, E.D.; Allen, E.J.; Jenkins, J.D.

    1978-05-01

    The use of Nondestructive Assay (NDA) instrumentation at a nuclear waste terminal storage facility for purposes of Special Nuclear Material (SNM) accountability is evaluated. Background information is given concerning general NDA techniques and the relative advantages and disadvantages of active and passive NDA methods are discussed. The projected characteristics and amounts of nuclear wastes that will be delivered to a waste terminal storage facility are presented. Wastes are divided into four categories: High Level Waste, Cladding Waste, Intermediate Level Waste, and Low Level Waste. Applications of NDA methods to the assay of these waste types is discussed. Several existing active and passive NDA instruments are described and, where applicable, results of assays performed on wastes in large containers (e.g., 55-gal drums) are given. It is concluded that it will be difficult to routinely achieve accuracies better than approximately 10--30% with ''simple'' NDA devices or 5--20% with more sohpisticated NDA instruments for compacted wastes. It is recommended that NDA instruments not be used for safeguards accountability at a waste storage facility. It is concluded that item accountability methods be implemented. These conclusions and recommendations are detailed in a concurrent report entitled ''Recommendations on the Safeguards Requirements Related to the Accountability of Special Nuclear Material at Waste Terminal Storage Facilities'' by J.D. Jenkins, E.J. Allen and E.D. Blakeman

  14. The Portable Dynamic Fundus Instrument: Uses in telemedicine and research

    Science.gov (United States)

    Hunter, Norwood; Caputo, Michael; Billica, Roger; Taylor, Gerald; Gibson, C. Robert; Manuel, F. Keith; Mader, Thomas; Meehan, Richard

    1994-01-01

    For years ophthalmic photographs have been used to track the progression of many ocular diseases such as macular degeneration and glaucoma as well as the ocular manifestations of diabetes, hypertension, and hypoxia. In 1987 a project was initiated at the Johnson Space Center (JSC) to develop a means of monitoring retinal vascular caliber and intracranial pressure during space flight. To conduct telemedicine during space flight operations, retinal images would require real-time transmissions from space. Film-based images would not be useful during in-flight operations. Video technology is beneficial in flight because the images may be acquired, recorded, and transmitted to the ground for rapid computer digital image processing and analysis. The computer analysis techniques developed for this project detected vessel caliber changes as small as 3 percent. In the field of telemedicine, the Portable Dynamic Fundus Instrument demonstrates the concept and utility of a small, self-contained video funduscope. It was used to record retinal images during the Gulf War and to transmit retinal images from the Space Shuttle Columbia during STS-50. There are plans to utilize this device to provide a mobile ophthalmic screening service in rural Texas. In the fall of 1993 a medical team in Boulder, Colorado, will transmit real-time images of the retina during remote consultation and diagnosis. The research applications of this device include the capability of operating in remote locations or small, confined test areas. There has been interest shown utilizing retinal imaging during high-G centrifuge tests, high-altitude chamber tests, and aircraft flight tests. A new design plan has been developed to incorporate the video instrumentation into face-mounted goggle. This design would eliminate head restraint devices, thus allowing full maneuverability to the subjects. Further development of software programs will broaden the application of the Portable Dynamic Fundus Instrument in

  15. The instrumentation calibration reduction program (ICRP) at Northeast Utilities

    International Nuclear Information System (INIS)

    Wyckoff, R.; Blanch, P.

    1987-01-01

    Northeast Utilities (NU) funded a project to study the feasibility of determining the state of core exit thermocouple (CET) calibration without having to have direct access to the CETs. Although the CETs were the prime focus, other safety related sensors were investigated. This paper describes presumptions and methods employed in the first phase, the feasibility study. Additionally, it describes the cost/benefit analysis which can be used by any utility to determine ICRP payback

  16. Application of physical separation techniques for waste utilization and management - case studies from Indian uranium deposits

    International Nuclear Information System (INIS)

    Anand Rao, K.; Sreenivas, T.

    2013-01-01

    The importance of physical beneficiation techniques in metallurgical industry showed gradual decline due to decreasing ore grades and very-fine size dissemination of valuable minerals in the host matrix. However, this technology regained prominence in recent past due to their utility in resource recycle, waste utilization, waste treatment and environmental remediation. Hybrid processes combined with physical, chemical and biological technology is now developing such that the idea of sustainable development is implemented. The uranium ore processing industry has always been under intense public scanner for some of the apprehensions, chiefly radioactivity, inspite of its immense energy delivering potential. Besides this, the chemical compounds formed due to gangue mineral reactivity and their carry-over to tailings pond added further owes. However, conscious scientific efforts are being made to contain these hazards to permissible levels by application of various remedial methods of which the physical separation techniques too are quite prominent

  17. Karolinska prostatectomy: a robot-assisted laparoscopic radical prostatectomy technique.

    Science.gov (United States)

    Nilsson, Andreas E; Carlsson, Stefan; Laven, Brett A; Wiklund, N Peter

    2006-01-01

    The last decade has witnessed an increasing trend towards minimally invasive management of prostate cancer, including laparoscopic and, more recently, robot-assisted laparoscopic prostatectomy. Several different laparoscopic approaches have been continuously developed during the last 5 years and it is still unclear which technique yields the best outcome. We present our current technique of robot-assisted laparoscopic radical prostatectomy. The technique described has evolved during the course of >400 robotic prostatectomies performed by the robotic team since the robot-assisted laparoscopic radical prostatectomy program was introduced at Karolinska University Hospital in January 2002. Our procedure comprises several modifications of previously reported ones, and we utilize fewer robotic instruments to reduce costs. An extended posterior dissection is performed to aid in the bladder neck-sparing dissection. In nerve-sparing procedures the vesicles are divided to avoid damage to the erectile nerves. In order to preserve the apical anatomy the dorsal venous complex is incised sharply and is first over-sewn after the apical dissection is completed. Our technique enables a more fluent dissection than previously described robotic techniques. Minimizing changes of instruments and the camera not only cuts costs but also reduces inefficient operating maneuvers, such as switching between 30 degrees and 0 degrees lenses during the procedure. We present a technique which in our hands has achieved excellent functional and oncological results.

  18. Refabricated and instrumented fuel rods

    International Nuclear Information System (INIS)

    Silberstein, K.

    2005-01-01

    Nuclear Fuel for power reactors capabilities evaluation is strongly based on the intimate knowledge of its behaviour under irradiation. This knowledge can be acquired from refabricated and instrumented fuel rods irradiated at different levels in commercial reactors. This paper presents the development and qualification of a new technique called RECTO related to a double-instrumented rod re-fabrication process developed by CEA/LECA hot laboratory facility at CADARACHE. The technique development includes manufacturing of the properly dimensioned cavity in the fuel pellet stack to house the thermocouple and the use of a newly designed pressure transducer. An analytic irradiation of such a double-instrumented fuel rod will be performed in OSIRIS test reactor starting October 2004. (Author)

  19. An overview of instrumentation for the Large Binocular Telescope

    Science.gov (United States)

    Wagner, R. Mark

    2012-09-01

    An overview of instrumentation for the Large Binocular Telescope (LBT) is presented. Optical instrumentation includes the Large Binocular Camera (LBC), a pair of wide-field (27' x 27') mosaic CCD imagers at the prime focus, and the Multi-Object Double Spectrograph (MODS), a pair of dual-beam blue-red optimized long-slit spectrographs mounted at the left and right direct F/15 Gregorian foci incorporating multiple slit masks for multi-object spectroscopy over a 6' field and spectral resolutions of up to 2000. Infrared instrumentation includes the LBT Near-IR Spectroscopic Utility with Camera and Integral Field Unit for Extragalactic Research (LUCI), a modular near-infrared (0.9-2.5 μm) imager and spectrograph pair mounted at the left and right front bent F/15 Gregorian foci and designed for seeing-limited (FOV: 4' × 4') imaging, long-slit spectroscopy, and multiobject spectroscopy utilizing cooled slit masks and diffraction limited (FOV: 0'.5 × 0'.5) imaging and long-slit spectroscopy. Strategic instruments under development that can utilize the full 23-m baseline of the LBT include an interferometric cryogenic beam combiner with near-infrared and thermal-infrared instruments for Fizeau imaging and nulling interferometry (LBTI) and an optical bench near-infrared beam combiner utilizing multi-conjugate adaptive optics for high angular resolution and sensitivity (LINC-NIRVANA). LBTI is currently undergoing commissioning on the LBT and utilizing the installed adaptive secondary mirrors in both single- sided and two-sided beam combination modes. In addition, a fiber-fed bench spectrograph (PEPSI) capable of ultra high resolution spectroscopy and spectropolarimetry (R = 40,000-300,000) will be available as a principal investigator instrument. Over the past four years the LBC pair, LUCI1, and MODS1 have been commissioned and are now scheduled for routine partner science observations. The delivery of both LUCI2 and MODS2 is anticipated before the end of 2012. The

  20. Review of crop growth and soil moisture monitoring from a ground-based instrument implementing the Interference Pattern GNSS-R Technique

    Science.gov (United States)

    Rodriguez-Alvarez, N.; Bosch-Lluis, X.; Camps, A.; Aguasca, A.; Vall-Llossera, M.; Valencia, E.; Ramos-Perez, I.; Park, H.

    2011-12-01

    Reflectometry using Global Navigation Satellite Systems signals (GNSSR) has been the focus of many studies during the past few years for a number of applications over different scenarios as land, ocean or snow and ice surfaces. In the past decade, its potential has increased yearly, with improved receivers and signal processors, from generic GNSS receivers whose signals were recorded in magnetic tapes to instruments that measure full Delay Doppler Maps (the power distribution of the reflected GNSS signal over the 2-D space of delay offsets and Doppler shifts) in real time. At present, these techniques are considered to be promising tools to retrieve geophysical parameters such as soil moisture, vegetation height, topography, altimetry, sea state and ice and snow thickness, among others. This paper focuses on the land geophysical retrievals (topography, vegetation height and soil moisture) performed from a ground-based instrument using the Interference Pattern Technique (IPT). This technique consists of the measurement of the power fluctuations of the interference signal resulting from the simultaneous reception of the direct and the reflected GNSS signals. The latest experiment performed using this technique over a maize field is shown in this paper. After a review of the previous results, this paper presents the latest experiment performed using this technique over a maize field. This new study provides a deeper analysis on the soil moisture retrieval by observing three irrigation-drying cycles and comparing them to different depths soil moisture probes. Furthermore, the height of the maize, almost 300 cm, has allowed testing the capabilities of the technique over dense and packed vegetation layers, with high vegetation water content.

  1. Performance of BATAN-SANS instrument

    Energy Technology Data Exchange (ETDEWEB)

    Ikram, Abarrul; Insani, Andon [National Nuclear Energy Agency, P and D Centre for Materials Science and Technology, Serpong (Indonesia)

    2003-03-01

    SANS data from some standard samples have been obtained using BATAN-SANS instrument in Serpong. The experiments were performed for various experimental set-ups that involve different detector positions and collimator lengths. This paper describes the BATAN-SANS instrument briefly as well as the data taken from those experiments and followed with discussion of the results concerning the performance and calibration of the instrument. The standard samples utilized in these experiments include porous silica, polystyrene-poly isoprene, silver behenate, poly ball and polystyrene-poly (ethylene-alt-propylene). Even though the results show that BATAN-SANS instrument is in good shape, but rooms for improvements are still widely open especially for the velocity selector and its control system. (author)

  2. Accuracy of Implant Placement Utilizing Customized Patient Instrumentation in Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    William D. Bugbee

    2013-01-01

    Full Text Available Customized patient instrumentation (CPI combines preoperative planning with customized cutting jigs to position and align implants during total knee arthroplasty (TKA. We compared postoperative implant alignment of patients undergoing surgery with CPI to traditional TKA instrumentation for accuracy of implant placement. Twenty-five consecutive TKAs using CPI were analyzed. Preoperative CT scans of the lower extremities were segmented using a computer program. Limb alignment and mechanical axis were computed. Virtual implantation of computer-aided design models was done. Postoperative coronal and sagittal view radiographs were obtained. Using 3D image-matching software, relative positions of femoral and tibial implants were determined. Twenty-five TKAs implanted using traditional instrumentation were also analyzed. For CPI, difference in alignment from the preoperative plan was calculated. In the CPI group, the mean absolute difference between the planned and actual femoral placements was 0.67° in the coronal plane and 1.2° in the sagittal plane. For tibial alignment, the mean absolute difference was 0.9° in the coronal plane and 1.3° in the sagittal plane. For traditional instrumentation, difference from ideal placement for the femur was 1.5° in the coronal plane and 2.3° in the sagittal plane. For the tibia, the difference was 1.8° in the coronal plane. CPI achieved accurate implant positioning and was superior to traditional TKA instrumentation.

  3. Utilizing Z-track Air Lock Technique to Reduce Pain in Intramuscular Injections

    Directory of Open Access Journals (Sweden)

    Evelyn Hemme Tambunan

    2015-04-01

    Full Text Available Introduction: Injection is one of most painful and common medical interventions that more than 12 billion of it are administered annually throughout the world. Pain remains as one of the unresolved health problems. The objective of this research was to investigate the pain severity utilizing the z-track air lock technique during intra muscular injection procedure. Method:This study was conducted as an unblinded cinical trial, where 90 female subjects aged between 18-25 years old were randomly assigned to three groups of 30. Each group received z-track air lock (Group ZTAL, air lock (AL, and z-track (Group ZT techniques. Neurobion 5000 vitamin used as an injection substance.A Verbal Rating Scale (VRS on 0–3 was used to evaluate the severity of pain during procedure. Data were analized using the SPSS version 19. Groups’ age, Body Mass Index (BMI and pain severity were analyzed through descriptive and One Way ANOVA statistics. Results: Results showed that there were no signifi cant differences of pain severity both within and between groups (p > 0.05. Discussion: Both Z-track and air lock method are less pain compared to traditional method according to previous studies. Noncicepti stimulus inhibited nocicepti stimulus in z-track technique while locking effect inhibit leakeage of substance injection to subcutaneous layer of skin which contain of nerve fi bers. However All techniques are recommended to produce less pain therefore it can be considered as a standard procedure for intra muscular injection. Keywords: intramuscular injection, z-track air lock technique, pain

  4. Novel technique for addressing streak artifact in gated dual-source MDCT angiography utilizing ECG-editing

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Laura T.; Boll, Daniel T. [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC (United States)

    2008-11-15

    Streak artifact is an important source of image degradation in computed tomographic imaging. In coronary MDCT angiography, streak artifact from pacemaker leads in the SVC can render segments of the right coronary artery uninterpretable. With current technology in clinical practice, there is no effective way to eliminate streak artifact in coronary MDCT angiography entirely. We propose a technique to minimize the impact of streak artifact in retrospectively gated coronary MDCT angiography by utilizing small shifts in the reconstruction window. In our experience, previously degraded portions of the coronary vasculature were able to be well evaluated using this technique. (orig.)

  5. Instrumentation utilisation for risk control in safety operations. [balloons and rockets

    Science.gov (United States)

    Swayer, F. R.

    1987-01-01

    Ways in which instrumentation is utilized for risk control for inherently safe (no control or guidance) and flight programmed launch vehicles is presented. Instrumentation and how it is utilized in the launching and recovery of balloons and payloads is also presented. Wind sensing, computer systems, tracking, and telemetry are discussed.

  6. Advanced Instrumentation and control techniques for nuclear power plants

    International Nuclear Information System (INIS)

    Mori, Nobuyuki; Makino, Maomi; Naito, Norio

    1992-01-01

    Toshiba has been promoting the development of an advanced instrumentation and control system for nuclear power plants to fulfill the requirements for increased reliability, improved functionality and maintainability, and more competitive economic performance. This system integrates state-of-the-art technologies such as those for the latest man-machine interface, digital processing, optical multiplexing signal transmission, human engineering, and artificial intelligence. Such development has been systematically accomplished based on a schematic view of integrated digital control and instrumentation systems, and the development of whole systems has now been completed. This paper describes the purpose, design philosophy, and contents of newly developed systems, then considers the future trends of advanced man-machine systems. (author)

  7. Instrumentation

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.G.

    1982-01-01

    This chapter reviews the parameters which are important to positron-imaging instruments. It summarizes the options which various groups have explored in designing tomographs and the methods which have been developed to overcome some of the limitations inherent in the technique as well as in present instruments. The chapter is not presented as a defense of positron imaging versus single-photon or other imaging modality, neither does it contain a description of various existing instruments, but rather stresses their common properties and problems. Design parameters which are considered are resolution, sampling requirements, sensitivity, methods of eliminating scattered radiation, random coincidences and attenuation. The implementation of these parameters is considered, with special reference to sampling, choice of detector material, detector ring diameter and shielding and variations in point spread function. Quantitation problems discussed are normalization, and attenuation and random corrections. Present developments mentioned are noise reduction through time-of-flight-assisted tomography and signal to noise improvements through high intrinsic resolution. Extensive bibliography. (U.K.)

  8. Overview of intercalibration of satellite instruments

    Science.gov (United States)

    Chander, G.; Hewison, T.J.; Fox, N.; Wu, X.; Xiong, X.; Blackwell, W.J.

    2013-01-01

    Inter-calibration of satellite instruments is critical for detection and quantification of changes in the Earth’s environment, weather forecasting, understanding climate processes, and monitoring climate and land cover change. These applications use data from many satellites; for the data to be inter-operable, the instruments must be cross-calibrated. To meet the stringent needs of such applications requires that instruments provide reliable, accurate, and consistent measurements over time. Robust techniques are required to ensure that observations from different instruments can be normalized to a common scale that the community agrees on. The long-term reliability of this process needs to be sustained in accordance with established reference standards and best practices. Furthermore, establishing physical meaning to the information through robust Système International d'unités (SI) traceable Calibration and Validation (Cal/Val) is essential to fully understand the parameters under observation. The processes of calibration, correction, stability monitoring, and quality assurance need to be underpinned and evidenced by comparison with “peer instruments” and, ideally, highly calibrated in-orbit reference instruments. Inter-calibration between instruments is a central pillar of the Cal/Val strategies of many national and international satellite remote sensing organizations. Inter-calibration techniques as outlined in this paper not only provide a practical means of identifying and correcting relative biases in radiometric calibration between instruments but also enable potential data gaps between measurement records in a critical time series to be bridged. Use of a robust set of internationally agreed upon and coordinated inter-calibration techniques will lead to significant improvement in the consistency between satellite instruments and facilitate accurate monitoring of the Earth’s climate at uncertainty levels needed to detect and attribute the mechanisms

  9. Scintigraphic instruments and techniques in nuclear medicine

    International Nuclear Information System (INIS)

    Bornand, B.; Soussaline, F.

    1977-03-01

    The development of new radiopharmaceuticals, cyclotron-produced radionuclides and improvement of detector, scanner and gamma camera characteristics have enable a remarkable recent progress in scintigraphic techniques for organ visualization and functional studies. Using a variety of techniques, positron cameras, section scanners, gamma holography, tomographic imaging appear to be playing an increasing important role. Data processing techniques, for example image processing and three dimensional reconstruction have significantly increased their impact. The principal research work and advances in technique achieved up to 1972 are summarized and the subjects which have been further exploited are outlined. The main section comprises references and abstracts of articles from scientific journals and conference proceedings (191 articles and 221 papers mentioned) for the period 1972-1975 to illustrate advances in this domain: Excerpta Medica (Nuclear Medicine) Abstract Journals and Nuclear Science Abstracts (1972-1975) were used as abstracting publications. This survey is completed with an index of authors and subject-matters. Eleven thesis are mentionned in an appendix [fr

  10. Comparing and transforming PROMIS utility values to the EQ-5D.

    Science.gov (United States)

    Hartman, John D; Craig, Benjamin M

    2018-03-01

    Summarizing patient-reported outcomes (PROs) on a quality-adjusted life year (QALY) scale is an essential component to any economic evaluation comparing alternative medical treatments. While multiple studies have compared PRO items and instruments based on their psychometric properties, no study has compared the preference-based summary of the EQ-5D-3L and Patient Reported Outcomes Measurement Information System (PROMIS-29) instruments. As part of this comparison, a major aim of this manuscript is to transform PROMIS-29 utility values to an EQ-5D-3L scale. A nationally representative survey of 2623 US adults completed the 29-item PROMIS health profile instrument (PROMIS-29) and the 3-level version of the EQ-5D instrument (EQ-5D-3L). Their responses were summarized on a health utility scale using published estimates. Using regression analysis, PROMIS-29 and EQ-5D-3L utility weights were compared with each other as well as with self-reported general health. PROMIS-29 utility weights were much lower than the EQ-5D-3L weights. However, a correlation coefficient of 0.769 between the utility values of the two instruments suggests that the main discordance is simply a difference in scale between the measures. It is also possible to map PROMIS-29 utility weights onto an EQ-5D-3L scale. EQ-5D-3L losses equal .1784 × (PROMIS-29 Losses) .7286 . The published estimates of the PROMIS-29 produce lower utility values than many other health instruments. Mapping the PROMIS-29 estimates to an EQ-5D-3L scale alleviates this issue and allows for a more straightforward comparison between the PROMIS-29 and other common health instruments.

  11. Lab-on-a-Chip Instrument Development for Titan Exploration

    Science.gov (United States)

    Willis, P. A.; Greer, F.; Fisher, A.; Hodyss, R. P.; Grunthaner, F.; Jiao, H.; Mair, D.; Harrison, J.

    2009-12-01

    This contribution will describe the initial stages of a new ASTID-funded research program initiated in Fall 2009 aimed at lab-on-a-chip system development for astrobiological investigations on Titan. This technology development builds off related work at JPL and Berkeley [1-3] on the ultrasensitive compositional and chiral analysis of amino acids on Mars in order to search for signatures of past or present life. The Mars-focused instrument system utilizes a microcapillary electrophoresis (μCE) system integrated with on-chip perfluoropolyether (PFPE) membrane valves and pumps for automated liquid sample handling, on-chip derivitization of samples with fluorescent tags, dilution, and mixing with standards for data calibration. It utilizes a four-layer wafer stack design with CE channels patterned in glass, along with a PFPE membrane, a pneumatic manifold layer, and a fluidic bus layer. Three pneumatically driven on-chip diaphragm valves placed in series are used to peristaltically pump reagents, buffers, and samples to and from capillary electrophoresis electrode well positions. Electrophoretic separation occurs in the all-glass channels near the base of the structure. The Titan specific lab-on-a-chip system under development here focuses its attention on the unique organic chemistry of Titan. In order to chromatographically separate mixtures of neutral organics such as polycyclic aromatic hydrocarbons (PAHs), the Titan-specific microfluidic platform utilizes the related technique of microcapillary electrochromatography (μCEC). This technique differs from conventional μCE in that microchannels are filled with a porous stationary phase that presents surfaces upon which analyte species can adsorb/desorb. It is this additional surface interaction that enables separations of species critical to the understanding of the astrobiological potential of Titan that are not readily separated by the μCE technique. We have developed two different approaches for the integration

  12. The Sound Access Parent Outcomes Instrument (SAPOI): Construction of a new instrument for children with severe multiple disabilities who use cochlear implants or hearing aids.

    Science.gov (United States)

    Hayward, Denyse V; Ritter, Kathryn; Mousavi, Amin; Vatanapour, Shabnam

    2016-01-01

    To report on the Phase 2 development of the Sound Access Parent Outcomes Instrument (SAPOI), a new instrument focused on formalizing outcomes that parents of children with severe multiple disabilities (SMD) who use amplification prioritize as important. Phase 2 of this project involved item selection and refinement of the SAPOI based on (a) Phase 1 study participant input, (b) clinical specialist feedback, and (c) test-retest instrument reliability. Phase 1 participant responses were utilized to construct a draft version of the SAPOI. Next, clinical specialists examined the instrument for content validity and utility and instrument reliability was examined through a test-retest process with parents of children with SMD. The draft SAPOI was constructed based on Phase 1 participant input. Clinical specialists supported content validity and utility of the instrument and the inclusion of 19 additional items across four categories, namely Child Affect, Child Interaction, Parent Well-being, and Child's Device Use. The SAPOI was completed twice at one-month intervals by parents of children with SMD to examine instrument reliability across the four categories (Child Affect, Child Interaction, Parent Well-being, and Child's Device Use). Instrument reliability was strong-to-excellent across all four sections. The SAPOI shows promise as a much-needed addition to the assessment battery currently used for children with SMD who use cochlear implants and hearing aids. It provides valuable information regarding outcomes resulting from access to sound in this population that currently used assessments do not identify.

  13. Advanced Instrumentation for Ultrafast Science at the LCLS

    Energy Technology Data Exchange (ETDEWEB)

    Berrah, Nora [Univ. of Connecticut, Storrs, CT (United States)

    2015-10-13

    This grant supported a Single Investigator and Small Group Research (SISGR) application to enable multi-user research in Ultrafast Science using the Linac Coherent Light Source (LCLS), the world’s first hard x-ray free electron laser (FEL) which lased for the first time at 1.5 Å on April 20, 2009. The goal of our proposal was to enable a New Era of Science by requesting funds to purchase and build Advanced Instrumentation for Ultrafast Science (AIUS), to utilize the intense, short x-ray pulses produced by the LCLS. The proposed instrumentation will allow peer review selected users to probe the ultrasmall and capture the ultrafast. These tools will expand on the investment already made in the construction of the light source and its instrumentation in both the LCLS and LUSI projects. The AIUS will provide researchers in the AMO, Chemical, Biological and Condensed Matter communities with greater flexibility in defining their scientific agenda at the LCLS. The proposed instrumentation will complement and significantly augment the present AMO instrument (funded through the LCLS project) through detectors and capabilities not included in the initial suite of instrumentation at the facility. We have built all of the instrumentations and they have been utilized by scientists. Please see report attached.

  14. Computer utility for interactive instrument control

    International Nuclear Information System (INIS)

    Day, P.

    1975-08-01

    A careful study of the ANL laboratory automation needs in 1967 led to the conclusion that a central computer could support all of the real-time needs of a diverse collection of research instruments. A suitable hardware configuration would require an operating system to provide effective protection, fast real-time response and efficient data transfer. An SDS Sigma 5 satisfied all hardware criteria, however it was necessary to write an original operating system; services include program generation, experiment control real-time analysis, interactive graphics and final analysis. The system is providing real-time support for 21 concurrently running experiments, including an automated neutron diffractometer, a pulsed NMR spectrometer and multi-particle detection systems. It guarantees the protection of each user's interests and dynamically assigns core memory, disk space and 9-track magnetic tape usage. Multiplexor hardware capability allows the transfer of data between a user's device and assigned core area at rates of 100,000 bytes/sec. Real-time histogram generation for a user can proceed at rates of 50,000 points/sec. The facility has been self-running (no computer operator) for five years with a mean time between failures of 10 []ays and an uptime of 157 hours/week. (auth)

  15. Vesical endometriosis: utility of imaging techniques

    International Nuclear Information System (INIS)

    Parra, M.; Cascon, E.; Robledo, R.; Perez, M.

    1999-01-01

    We present three cases of vesical endometriosis initially studied with ultrasound. One case was also studied with intravenous urography, computed tomography and magnetic resonance imaging. We discuss on the utility of these imaging methods in the diagnosis of vesical endometriosis. (Author) 9 refs

  16. Advanced Technologies For Heterodyne Radio Astronomy Instrumentation - Part1 By A. Pavolotsky, And Advanced Technologies For Heterodyne Radio Astronomy Instrumentation - Part2 By V. Desmaris

    Science.gov (United States)

    Pavolotsky, Alexey

    2018-01-01

    Modern and future heterodyne radio astronomy instrumentation critically depends on availability of advanced fabrication technologies and components. In Part1 of the Poster, we present the thin film fabrication process for SIS mixer receivers, utilizing either AlOx, or AlN barrier superconducting tunnel junctions developed and supported by GARD. The summary of the process design rules is presented. It is well known that performance of waveguide mixer components critically depends on accuracy of their geometrical dimensions. At GARD, all critical mechanical parts are 3D-mapped with a sub-um accuracy. Further progress of heterodyne instrumentation requires new efficient and compact sources of LO signal. We present SIS-based frequency multiplier, which could become a new option for LO source. Future radio astronomy THz receivers will need waveguide components, which fabricating due to their tiny dimensions is not feasible by traditional mechanical machining. We present the alternative micromachining technique for fabricating waveguide component for up 5 THz band and probably beyond.

  17. Development of nano-fabrication technique utilizing self-organizational behavior of point defects induced by ion irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Nitta, Noriko [Department of Environmental Systems Engineering, Kochi University of Technology, Tosayamada-Cho, Kochi-Prefecture 782-8502 (Japan); Taniwaki, Masafumi [Department of Environmental Systems Engineering, Kochi University of Technology, Tosayamada-Cho, Kochi-Prefecture 782-8502 (Japan)]. E-mail: taniwaki.masafumi@kochi-tech.ac.jp

    2006-04-01

    The present authors proposed a novel nano-fabrication technique that is able to arrange the fine cells orderly, based on their finding in GaSb implanted at a low temperature. In this article, first the experimental results that anomalous cellular structure was formed in GaSb by ion implantation is introduced and the self-organizational formation mechanism of the structure is described. Next a nano-fabrication technique that utilizes focused ion beam is described. This technique consists of two procedures, i.e. the formation process of the voids array and the development of the initial array to ordered cellular structure. Finally, the nano-fabrication is actually performed by this technique and their results are reported. Fabrication succeeded in structures where the dot (cell) interval was 100 nm or larger. The minimum ion dose for initial voids which develops to the ordered cellular structure is evaluated. It is also shown that the substrate temperature during implantation is an essential parameter for this technique.

  18. Development of nano-fabrication technique utilizing self-organizational behavior of point defects induced by ion irradiation

    International Nuclear Information System (INIS)

    Nitta, Noriko; Taniwaki, Masafumi

    2006-01-01

    The present authors proposed a novel nano-fabrication technique that is able to arrange the fine cells orderly, based on their finding in GaSb implanted at a low temperature. In this article, first the experimental results that anomalous cellular structure was formed in GaSb by ion implantation is introduced and the self-organizational formation mechanism of the structure is described. Next a nano-fabrication technique that utilizes focused ion beam is described. This technique consists of two procedures, i.e. the formation process of the voids array and the development of the initial array to ordered cellular structure. Finally, the nano-fabrication is actually performed by this technique and their results are reported. Fabrication succeeded in structures where the dot (cell) interval was 100 nm or larger. The minimum ion dose for initial voids which develops to the ordered cellular structure is evaluated. It is also shown that the substrate temperature during implantation is an essential parameter for this technique

  19. Optical fibers and their instrumentation applications

    International Nuclear Information System (INIS)

    Boisde, Gilbert.

    1982-09-01

    The use of optical fibers in instrumentation requires a knowledge of their properties as ''photon carriers'' and ''sensors''. New instrumentation design implies a satisfactory evaluation of the entire measurement circuit, including the emitter, optical coupling, optical fiber with its physical, spectral and physico-chemical properties, the connector, receiver, signal amplifier and data processing system. An example, is provided of the development of a new technique in physico-chemical instrumentation: remote spectrophotometry. Three aspects are discussed: 1) industrial measurement in ''process control'' using the Telephot (R), 2) remote spectral measurement, 3) opical multiplexing. This is followed by a review of various optical fiber based instrumental techniques used in the fields of medicine (endoscopy, fluorothermy, laser surgery), solar energy industrial applications subject to electrical disturbances (position sensors, strain measurements), and in physico-chemical analysis (fluorescence, redox potentials) [fr

  20. Introduction to digital instrumentation and control techniques used in nuclear engineering

    International Nuclear Information System (INIS)

    Kurilla, R.G.; Kenney, E.S.

    1988-01-01

    For the past 8 yr, the nuclear engineering department at Pennsylvania State University has been teaching a digital interfacing class at the undergraduate (senior) level. With the ever-increasing use of computers in the nuclear engineering area (such as in the use of automated data acquisition systems) and the complexity of control instrumentation, more than a cursory introduction into electronics and computer controls is needed. Because of the ever-increasing popularity, and hence importance, of IBM-PC compatible microcomputers in the engineering fields, the program has been adapted to the Intel 8086 microprocessor. Courses such as this one are helpful in ensuring the students have an adequate design and practice base as required by accrediting groups. The course, is composed of three parts: (1) machine code/assembly language, (2) interfacing, and (3) final project. Experience demonstrates that a course of this inherent complexity can successfully be taught within a nuclear engineering curriculum without extensive prerequisites. The important ingredient is to treat nuclear engineering students for exactly what they are, engineers. By having them use their creativity and adaptability, they can successfully integrate the digital interfacing techniques now routinely used in the nuclear industry

  1. Concerning the application of the nuclear and related techniques

    International Nuclear Information System (INIS)

    Desdin Garcia, Luis Felipe

    1997-01-01

    The present work intends to describe briefly, some of the nuclear and connected techniques of greater application in the conditions of developing countries, which are employed in the Center of Studies Applied to the Nuclear Development, and that can be of interest for the Latin-American countries. Within those techniques we have: radiobiology, that consists of the employment of ionizing radiations to induce mutations oriented to the improvement of the cultivations. It mentions the atmospheric contamination generated by the industry of the exposition to metals and toxic waste, and of mortiferous parasites that adapt quickly to the unhealthy environmental conditions. It also enumerates some advantages of the utilization of instruments based on radioisotopic fountains. (S. Grainger) [es

  2. Spectrometric techniques 3

    CERN Document Server

    Vanasse, George A

    2013-01-01

    Spectrometric Techniques, Volume III presents the applications of spectrometric techniques to atmospheric and space studies. This book reviews the spectral data processing and analysis techniques that are of broad applicability.Organized into five chapters, this volume begins with an overview of the instrumentation used for obtaining field data. This text then reviews the contribution that space-borne spectroscopy in the thermal IR has made to the understanding of the planets. Other chapters consider the instruments that have recorded the planetary emission spectra. This book discusses as well

  3. On-line Monitoring of Instrumentation in Research Reactors

    International Nuclear Information System (INIS)

    2017-12-01

    This publication is the result of a benchmarking effort undertaken under the IAEA coordinated research project on improved instrumentation and control (I&C) maintenance techniques for research reactors. It lays the foundation for implementation of on-line monitoring (OLM) techniques and establishment of the validity of those for improved maintenance practices in research reactors for a number of applications such as change to condition based calibration, performance monitoring of process instrumentation systems, detection of process anomalies and to distinguish between process problems/effects and instrumentation/sensor issues. The techniques and guidance embodied in this publication will serve the research reactor community in providing the technical foundation for implementation of OLM techniques. It is intended to be used by Member States to implement I&C maintenance and to improve performance of research reactors.

  4. Neutron Scattering in Biology Techniques and Applications

    CERN Document Server

    Fitter, Jörg; Katsaras, John

    2006-01-01

    The advent of new neutron facilities and the improvement of existing sources and instruments world wide supply the biological community with many new opportunities in the areas of structural biology and biological physics. The present volume offers a clear description of the various neutron-scattering techniques currently being used to answer biologically relevant questions. Their utility is illustrated through examples by some of the leading researchers in the field of neutron scattering. This volume will be a reference for researchers and a step-by-step guide for young scientists entering the field and the advanced graduate student.

  5. Advanced sampling techniques for hand-held FT-IR instrumentation

    Science.gov (United States)

    Arnó, Josep; Frunzi, Michael; Weber, Chris; Levy, Dustin

    2013-05-01

    FT-IR spectroscopy is the technology of choice to identify solid and liquid phase unknown samples. The challenging ConOps in emergency response and military field applications require a significant redesign of the stationary FT-IR bench-top instruments typically used in laboratories. Specifically, field portable units require high levels of resistance against mechanical shock and chemical attack, ease of use in restrictive gear, extreme reliability, quick and easy interpretation of results, and reduced size. In the last 20 years, FT-IR instruments have been re-engineered to fit in small suitcases for field portable use and recently further miniaturized for handheld operation. This article introduces the HazMatID™ Elite, a FT-IR instrument designed to balance the portability advantages of a handheld device with the performance challenges associated with miniaturization. In this paper, special focus will be given to the HazMatID Elite's sampling interfaces optimized to collect and interrogate different types of samples: accumulated material using the on-board ATR press, dispersed powders using the ClearSampler™ tool, and the touch-to-sample sensor for direct liquid sampling. The application of the novel sample swipe accessory (ClearSampler) to collect material from surfaces will be discussed in some detail. The accessory was tested and evaluated for the detection of explosive residues before and after detonation. Experimental results derived from these investigations will be described in an effort to outline the advantages of this technology over existing sampling methods.

  6. Measurement, instrumentation, and sensors handbook

    CERN Document Server

    Eren, Halit

    2014-01-01

    The Second Edition of the bestselling Measurement, Instrumentation, and Sensors Handbook brings together all aspects of the design and implementation of measurement, instrumentation, and sensors. Reflecting the current state of the art, it describes the use of instruments and techniques for performing practical measurements in engineering, physics, chemistry, and the life sciences and discusses processing systems, automatic data acquisition, reduction and analysis, operation characteristics, accuracy, errors, calibrations, and the incorporation of standards for control purposes. Organized acco

  7. Ex vivo evaluation of various instrumentation techniques and irrigants in reducing E. faecalis within root canals.

    Science.gov (United States)

    Basmaci, F; Oztan, M D; Kiyan, M

    2013-09-01

    To evaluate ex vivo the effectiveness of single-file instrumentation techniques compared with serial Ni-Ti rotary instrumentation with several irrigation regimens in reducing E. faecalis within root canals. A total of 81 extracted human mandibular premolar teeth with a single root canal were infected with E. faecalis before and after canal preparation. Samples were divided randomly into 9 groups, as follows: group 1-A: sterile phosphate-buffered saline + Self-adjusting file, group 1-B: 5% sodium hypochlorite + 15% EDTA + Self-adjusting file, group 1-C: 5% sodium hypochlorite + 7% maleic acid + Self-adjusting file, group 2-A: sterile phosphate-buffered saline + Reciproc (R25), group 2-B: 5% sodium hypochlorite + 15% EDTA + Reciproc (R25), group 2-C: 5% sodium hypochlorite + 7% maleic acid + Reciproc (R25), group 3-A: sterile phosphate-buffered saline + ProTaper, group 3-B: 5% sodium hypochlorite + 15% EDTA + ProTaper, group 3-C: 5% sodium hypochlorite + 7% maleic acid + ProTaper. anova was used to analyse statistically the differences in terms of reduction in colony counts between the groups, and Dunn's post hoc test was used for multiple comparisons. All techniques and irrigation regimens significantly reduced the number of bacterial cells in the root canal (P irrigants. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  8. Small-angle neutron scattering instrument at MINT

    International Nuclear Information System (INIS)

    Mohd Ali Sufi; Yusof Abdullah; Razali Kassim; Hamid; Shahidan Radiman; Mohammad Deraman; Abdul Ghaffar Ramli

    1996-01-01

    The Small Angle Neutron Scattering (SANS) Instrument has been developed at Malaysian Institute for Nuclear Technology Research (MINT) for studying structural properties of materials on the length scale 1 nm to 100 nm. This is the length scale which is relevant for many topics within soft condensed matter, like polymers, colloids, biological macromolecules, etc. The SANS is a complementary technique to X-ray and electron scattering. However, while these later techniques give information on structures near surface, SANS concerns the structure of the bulk. Samples studied by SANS technique are typically bulk materials of the sizes mm's to cm's, or materials dissolved in a liquid. This paper described the general characteristics of SANS instrument as well as the experimental formulation in neutron scattering. The preliminary results obtained by this instrument are shown

  9. Utilization of induced mutation techniques in rice improvement in the Philippines

    International Nuclear Information System (INIS)

    Asencion, A.B.; Santos, I.S.; Barrida, A.C.; Medina, F.I.S. III

    2001-01-01

    Rice is one of the most important food crops in the Philippines, as such, efforts have been made consistently to improve the varieties released to the farmers for planting. Both conventional and induced mutation techniques were utilized to solve some of the problems. Varieties with improved qualities, resistance to pests and diseases, reduced height, early maturity and non-photoperiod sensitive were developed using either physical or chemical mutagen. Other methods were also tried to enhance variability like combination of gamma irradiation and biotechnology. Irradiation of F1 seeds was also initiated including the use of mutants in crosses to transfer their improved mutated characters. Promising selections were already tested and six lines from the F1 irradiation out-yielded both C4-63G and IR 1561-288-3, their parents. (author)

  10. Utilization of induced mutation techniques in rice improvement in the Philippines

    Energy Technology Data Exchange (ETDEWEB)

    Asencion, A.B.; Santos, I.S.; Barrida, A.C.; Medina, F.I.S. III [Philippine Nuclear Research Institute, Atomic Research Center (Philippines)

    2001-03-01

    Rice is one of the most important food crops in the Philippines, as such, efforts have been made consistently to improve the varieties released to the farmers for planting. Both conventional and induced mutation techniques were utilized to solve some of the problems. Varieties with improved qualities, resistance to pests and diseases, reduced height, early maturity and non-photoperiod sensitive were developed using either physical or chemical mutagen. Other methods were also tried to enhance variability like combination of gamma irradiation and biotechnology. Irradiation of F1 seeds was also initiated including the use of mutants in crosses to transfer their improved mutated characters. Promising selections were already tested and six lines from the F1 irradiation out-yielded both C4-63G and IR 1561-288-3, their parents. (author)

  11. Protaper--hybrid technique.

    Science.gov (United States)

    Simon, Stephane; Lumley, Philip; Tomson, Phillip; Pertot, Wilhelm-Joseph; Machtou, Pierre

    2008-03-01

    Crown down preparation is the most known and described technique since the introduction of Nickel Titanium (NiTi) rotary instruments in endodontics. This technique gives good results but has limitations, such as not addressing the initial anatomy of oval or dumb-bell shaped canals. The specific design of the Protaper instruments allows use of them with a different technique and, specifically, with a brushing motion in the body of the canal. The recent introduction of hand Protaper files has expanded the range of application of this system, especially in curved canals. The 'hybrid technique', using rotary and hand files, and the advantages of the combination of both instruments, are clearly described in this article. Used with this technique, the Protaper is a very safe system to use, and more controllable, for both inexperienced and experienced practitioners alike, than other systems. To understand the precautions needed with rotary files, and how to use them to preserve the anatomy of the canal and get a tapered shaping, even in severely curved canals.

  12. Intercomparison of different instruments that measure radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, M.; Iida, T.; Ikebe, Y.

    1987-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap technique, a flow-type ionization chamber (pulse-counting technique), a two-filter method, an electrostatic collection method and a passive integrating radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq/m/sup 3/ (in outdoor air) to 110 Bq/m/sup 3/ (in indoor air). The results obtained from these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling technique was about 52% of radon concentrations

  13. Virtual instrumentation technique used in the nuclear digital signal processing system design: Energy and time measurement tests

    International Nuclear Information System (INIS)

    Pechousek, J.; Prochazka, R.; Prochazka, V.; Frydrych, J.

    2011-01-01

    In this report, computer-based digital signal processing system with a 200 MS s -1 sampling digitizer is presented. Virtual instrumentation technique is used to easily develop a system which provides spectroscopy measurements such as amplitude and time signal analysis, with the time-of-flight facility. Several test measurements were performed to determine the characteristics of a system. The presented system may find its application in the coincidence measurement since the system is usable for different types of detectors and sensitive to decay lifetimes from tens of nanoseconds to seconds.

  14. Repairing method of color TV with measuring instrument

    International Nuclear Information System (INIS)

    1996-01-01

    This book concentrates on repairing method of color TV with measuring instrument, which deals with direction and sorts of measuring instrument for service, application and basic technique of an oscilloscope and a synchroscope, constituent of TV and wave reading, everything for test skill for service man, service technique by electronic voltmeter, service technique by sweep generator and maker generator, dot-bar generator and support skill for color TV and color bar generator and application technology of color circuit.

  15. The history of thoracic surgical instruments and instrumentation.

    Science.gov (United States)

    Hagopian, E J; Mann, C; Galibert, L A; Steichen, F M

    2000-02-01

    Thoracic surgical practice has evolved from the innovations of its pioneers. Beginning with the stethoscope discovered by Laënnec with his system of auscultation, to the tools we use in the dissection and control of the hilum of the lung for resection, our practice of thoracic surgery has been entwined with the development of instruments and instrumentation. The development of strategies to prevent death from the open pneumothorax began with manual control of the mediastinum and progressed through differential pressure to, finally, the technique of intubation and the methods of positive-pressure and insufflation anesthesia. The instruments we place in our hands are not enough to define our art. Entry into the chest would not be possible without the use of rib retractors, rib shears, and even periosteal elevators. Finally, to the present day of minimally invasive techniques and the application of thoracoscopy for therapeutic purposes, we find the efforts of our predecessors well developed. For the progression from the fear of the open pneumothorax to the present-day state of the ease of thoracotomy for lung resection we are indebted to those who gave so much of their time and, for some, their lives to death from tuberculosis, to allow the advancement of our practice of surgery. These great people should be remembered not only for their acceptance of novel ideas but also, more importantly, for their lack of fear of testing them.

  16. Patient-Specific CT-Based Instrumentation versus Conventional Instrumentation in Total Knee Arthroplasty: A Prospective Randomized Controlled Study on Clinical Outcomes and In-Hospital Data

    Directory of Open Access Journals (Sweden)

    Andrzej Kotela

    2015-01-01

    Full Text Available Total knee arthroplasty (TKA is a frequently performed procedure in orthopaedic surgery. Recently, patient-specific instrumentation was introduced to facilitate correct positioning of implants. The aim of this study was to compare the early clinical results of TKA performed with patient-specific CT-based instrumentation and conventional technique. A prospective, randomized controlled trial on 112 patients was performed between January 2011 and December 2011. A group of 112 patients who met the inclusion and exclusion criteria were enrolled in this study and randomly assigned to an experimental or control group. The experimental group comprised 52 patients who received the Signature CT-based implant positioning system, and the control group consisted of 60 patients with conventional instrumentation. Clinical outcomes were evaluated with the KSS scale, WOMAC scale, and VAS scales to assess knee pain severity and patient satisfaction with the surgery. Specified in-hospital data were recorded. Patients were followed up for 12 months. At one year after surgery, there were no statistically significant differences between groups with respect to clinical outcomes and in-hospital data, including operative time, blood loss, hospital length of stay, intraoperative observations, and postoperative complications. Further high-quality investigations of various patient-specific systems and longer follow-up may be helpful in assessing their utility for TKA.

  17. Dealing with the paradox of energy efficiency promotion by electric utilities

    International Nuclear Information System (INIS)

    Sousa, José Luís; Martins, António Gomes; Jorge, Humberto

    2013-01-01

    Utility-based Demand-Side Management (DSM) programmes started after the oil crises of the 70's and were adopted by utilities as a standard practice. However, deregulation of the electricity industry threatened DSM. More recent concerns regarding energy dependence and environmental impact of energy use caused renewed attention on the utilities role in energy efficiency fostering. EE is presently a cross-cutting issue, influencing energy policy definition and regulatory activity worldwide. Some instruments for influencing the behaviour of electric utilities in the market are used by regulators, corresponding to both impositions and stimuli, such as defining savings targets or decoupling profits from energy sales. The paper addresses categories of regulatory instruments and refers to examples of countries and regions using these identified categories of instruments. Although some cases show voluntary involvement of utilities in EE promotion on the grounds of customer retention strategies, there is a clear prevalence of regulatory constrained markets where utilities rationally engage in energy efficiency promotion

  18. [French residents' training in instrumental deliveries: A national survey].

    Science.gov (United States)

    Saunier, C; Raimond, E; Dupont, A; Pelissier, A; Bonneau, S; Gabriel, R; Graesslin, O

    2016-11-01

    To evaluate French residents in Obstetrics and Gynaecology's training in instrumental deliveries in 2015. We conducted a national descriptive survey among 758 residents between December 2014 and January 2015. Respondents were invited by email to specify their University Hospital, their current university term, the number of instrumental deliveries performed by vacuum extractor, forceps or spatulas, and whether they made systematic ultrasound exams before performing the extraction. Response rate was 34.7 % (n=263). There were important differences between regions in terms of type of instruments used. Vacuum extractor was the most commonly used instrument for instrumental deliveries by French residents (56.9 %), more than forceps (25.2 %) and spatulas (17.9 %). At the end of the residency, all the residents had been trained in instrumental deliveries with at least two instruments. The training of difficult techniques as well as their perfect control is required for instrumental deliveries. Yet, we are forced to note that there are substantial differences in the French residents' training in instrumental deliveries depending on their region. So, teaching at least two techniques seems essential as well as improving the training capacities and standardizing practices. A greater systematization of the teaching of the mechanics and obstetric techniques might be a solution to be considered too. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  19. Monte Carlo simulations of neutron scattering instruments

    International Nuclear Information System (INIS)

    Aestrand, Per-Olof; Copenhagen Univ.; Lefmann, K.; Nielsen, K.

    2001-01-01

    A Monte Carlo simulation is an important computational tool used in many areas of science and engineering. The use of Monte Carlo techniques for simulating neutron scattering instruments is discussed. The basic ideas, techniques and approximations are presented. Since the construction of a neutron scattering instrument is very expensive, Monte Carlo software used for design of instruments have to be validated and tested extensively. The McStas software was designed with these aspects in mind and some of the basic principles of the McStas software will be discussed. Finally, some future prospects are discussed for using Monte Carlo simulations in optimizing neutron scattering experiments. (R.P.)

  20. Robotic, MEMS-based Multi Utility Sample Preparation Instrument for ISS Biological Workstation, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This project will develop a multi-functional, automated sample preparation instrument for biological wet-lab workstations on the ISS. The instrument is based on a...

  1. Maintenance of scientific instruments

    International Nuclear Information System (INIS)

    Lucero, E.

    1986-01-01

    During the last years Colombia has increased the use of nuclear techniques, instruments and equipment in ambitious health programs, as well as in research centers, industry and education; this has resulted in numerous maintenance problems. As an alternative solution IAN has established a Central Maintenance Laboratory for nuclear instruments within an International Atomic Energy Agency program for eight Latin American and nine Asian Countries. Established strategies and some results are detailed in this writing

  2. Application of advanced nuclear and instrumental analytical techniques for characterisation of environmental materials

    International Nuclear Information System (INIS)

    Sudersanan, M.; Pawaskar, P.B.; Kayasth, S.R.; Kumar, S.C.

    2002-01-01

    Full text: Increasing realisation about the toxic effects of metal ions in environmental materials has given an impetus to research on analytical techniques for their characterization. The large number of analytes present at very low levels has necessitated the use of sensitive, selective and element specific techniques for their characterization. The concern about precision and accuracy on such analysis, which have socio-economic bearing, has emphasized the use of Certified Reference Materials and the use of multi-technique approach for the unambiguous characterization of analytes. The recent work carried out at Analytical Chemistry Division, BARC on these aspects is presented in this paper. Increasing use of fossil fuels has led to the generation of large quantities of fly ash which pose problems of safe disposal. The utilization of these materials for land filling is an attractive option but the presence of trace amounts of toxic metals like mercury, arsenic, lead etc may cause environmental problems. In view of the inhomogeneous nature of the material, efficient sample processing is an important factor, in addition to the validation of the results by the use of proper standards. Analysis was carried out on flyash samples received as reference materials and also as samples from commercial sources using a combination of both nuclear techniques like INAA and RNAA as well as other techniques like AAS, ICPAES, cold vapour AAS for mercury and hydride generation technique for arsenic. Similar analysis using nuclear techniques was employed for the characterization of air particulates. Biological materials often serve as sensitive indicator materials for pollution measurements. They are also employed for studies on the uptake of toxic metals like U, Th, Cd, Pb, Hg etc. The presence of large amounts of organic materials in them necessitate an appropriate sample dissolution procedure. In view of the possibility of loss of certain analytes like Cd, Hg, As, by high

  3. Scintigraphic instruments and techniques in nuclear medicine

    International Nuclear Information System (INIS)

    Bornand, Bernard; Soussaline Francoise

    1979-11-01

    This bibliographical supplement brings out the importance assumed from now on by comparative studies on various imagery systems: radioisotopic scintigraphy, computerized tomography and ultra sonography. Another aspect to emerge is the anxiety of the medical world faced with ethical and economic problems in weighing up as accurately as possible the justifiability and consequences of clinical decisions, hence the value of visual observations and interpretations of images, as well as the quality of the instruments used. Four lists of bibliographical notices with abstracts covering the period late 1976-early 1979 mention 258 articles from journals, 67 conference lectures, 13 reports, 3 theses and 44 invention patents respectively. To these lists are attached the author, inventor and subject indices [fr

  4. Current activities in development of PIE techniques in JMTR hot laboratory

    International Nuclear Information System (INIS)

    Ishii, Toshimitsu; Ohmi, Masao; Shimizu, Michio; Kaji, Yoshiyuki; Ueno, Fumiyoshi

    2006-01-01

    A wide variety of post-irradiation examinations (PIEs) for research and development of nuclear fuels and materials to be utilized in nuclear field has been carried out since 1971 in three kinds of β-γ hot cells; concrete, lead and steel cells in the JMTR Hot Laboratory (JMTR HL) associated with the Japan Materials Testing Reactor (JMTR). In addition to PIEs, the re-capsuling work including re-instrumentation was also conducted for the power ramping tests of the irradiated LWR fuels using Boiling Water Capsule (BOCA). Recently, new PIE techniques are required for the advanced irradiation studies. In this paper, the irradiation assisted stress corrosion cracking (IASCC) growth test technique of irradiated in-core structural materials and the remote operation technique of the atomic force microscope (AFM) are described as JMTR HL's current activities in the development of new PIE techniques. (author)

  5. New technology and techniques for x-ray mirror calibration at PANTER

    Science.gov (United States)

    Freyberg, Michael J.; Budau, Bernd; Burkert, Wolfgang; Friedrich, Peter; Hartner, Gisela; Misaki, Kazutami; Mühlegger, Martin

    2008-07-01

    The PANTER X-ray Test Facility has been utilized successfully for developing and calibrating X-ray astronomical instrumentation for observatories such as ROSAT, Chandra, XMM-Newton, Swift, etc. Future missions like eROSITA, SIMBOL-X, or XEUS require improved spatial resolution and broader energy band pass, both for optics and for cameras. Calibration campaigns at PANTER have made use of flight spare instrumentation for space applications; here we report on a new dedicated CCD camera for on-ground calibration, called TRoPIC. As the CCD is similar to ones used for eROSITA (pn-type, back-illuminated, 75 μm pixel size, frame store mode, 450 μm micron wafer thickness, etc.) it can serve as prototype for eROSITA camera development. New techniques enable and enhance the analysis of measurements of eROSITA shells or silicon pore optics. Specifically, we show how sub-pixel resolution can be utilized to improve spatial resolution and subsequently the characterization of of mirror shell quality and of point spread function parameters in particular, also relevant for position reconstruction of astronomical sources in orbit.

  6. A Comparison of Apical Bacterial Extrusion in Manual, ProTaper Rotary, and One Shape Rotary Instrumentation Techniques.

    Science.gov (United States)

    Mittal, Rakesh; Singla, Meenu G; Garg, Ashima; Dhawan, Anu

    2015-12-01

    Apical extrusion of irrigants and debris is an inherent limitation associated with cleaning and shaping of root canals and has been studied extensively because of its clinical relevance as a cause of flare-ups. Many factors affect the amount of extruded intracanal materials. The purpose of this study was to assess the bacterial extrusion by using manual, multiple-file continuous rotary system (ProTaper) and single-file continuous rotary system (One Shape). Forty-two human mandibular premolars were inoculated with Enterococcus faecalis by using a bacterial extrusion model. The teeth were divided into 3 experimental groups (n = 12) and 1 control group (n = 6). The root canals of experimental groups were instrumented according to the manufacturers' instructions by using manual technique, ProTaper rotary system, or One Shape rotary system. Sterilized saline was used as an irrigant, and bacterial extrusion was quantified as colony-forming units/milliliter. The results obtained were statistically analyzed by using one-way analysis of variance for intergroup comparison and post hoc Tukey test for pair-wise comparison. The level for accepting statistical significance was set at P step-back technique exhibiting significantly more bacterial extrusion than the engine-driven systems. Of the 2 engine-driven systems, ProTaper rotary extruded significantly more bacteria than One Shape rotary system (P engine-driven nickel-titanium systems were associated with less apical extrusion. The instrument design may play a role in amount of extrusion. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. Advanced accounting techniques in automated fuel fabrication facilities

    International Nuclear Information System (INIS)

    Carlson, R.L.; DeMerschman, A.W.; Engel, D.W.

    1977-01-01

    The accountability system being designed for automated fuel fabrication facilities will provide real-time information on all Special Nuclear Material (SNM) located in the facility. It will utilize a distributed network of microprocessors and minicomputers to monitor material movement and obtain nuclear materials measurements directly from remote, in-line Nondestructive Assay instrumentation. As SNM crosses an accounting boundary, the accountability computer will update the master files and generate audit trail records. Mass balance accounting techniques will be used around each unit process step, while item control will be used to account for encapsulated material, and SNM in transit

  8. Costing for long-term care: the development of Scottish health service resource utilization groups as a casemix instrument.

    Science.gov (United States)

    Urquhart, J; Kennie, D C; Murdoch, P S; Smith, R G; Lennox, I

    1999-03-01

    to create a casemix measure with a limited number of categories which discriminate in terms of resource use and will assist in the development of a currency for contracting for the provision of health care. nursing staff completed a questionnaire providing clinical data and also gave estimates of relative patient resource use; ward-based costs were collected from appropriate unit managers. National Health Service continuing-care wards in 50 Scottish hospitals. 2783 long-stay patients aged 65 years and over. inter-rater reliability was assessed using 1402 patients; percentage agreement between raters for individual variables varied from 68% for feeding to 97% for clinically complex treatments. Nursing costs gave 62% agreement given categories of high, medium and low. The Scottish health service resource utilization groups (SHRUG) measure was developed using 606 cases, and 67% consistency was achieved for the five categories. The relative weights for the SHRUG categories ranged from 0.56 to 1.41. The five categories explain 35% of variance in costs. the five SHRUG casemix categories show good discrimination in terms of costs. The SHRUG measure compares favourably with diagnosis-related groups in the acute sector and with other casemix instruments for long-term care previously piloted in the UK. SHRUG is a useful measurement instrument in assessing the resource needs of elderly people in long-term care.

  9. Optical techniques for the determination of nitrate in environmental waters: Guidelines for instrument selection, operation, deployment, maintenance, quality assurance, and data reporting

    Science.gov (United States)

    Pellerin, Brian A.; Bergamaschi, Brian A.; Downing, Bryan D.; Saraceno, John Franco; Garrett, Jessica D.; Olsen, Lisa D.

    2013-01-01

    The recent commercial availability of in situ optical sensors, together with new techniques for data collection and analysis, provides the opportunity to monitor a wide range of water-quality constituents on time scales in which environmental conditions actually change. Of particular interest is the application of ultraviolet (UV) photometers for in situ determination of nitrate concentrations in rivers and streams. The variety of UV nitrate sensors currently available differ in several important ways related to instrument design that affect the accuracy of their nitrate concentration measurements in different types of natural waters. This report provides information about selection and use of UV nitrate sensors by the U.S. Geological Survey to facilitate the collection of high-quality data across studies, sites, and instrument types. For those in need of technical background and information about sensor selection, this report addresses the operating principles, key features and sensor design, sensor characterization techniques and typical interferences, and approaches for sensor deployment. For those needing information about maintaining sensor performance in the field, key sections in this report address maintenance and calibration protocols, quality-assurance techniques, and data formats and reporting. Although the focus of this report is UV nitrate sensors, many of the principles can be applied to other in situ optical sensors for water-quality studies.

  10. Mass Spectrometric C-14 Detection Techniques: Progress Report

    Science.gov (United States)

    Synal, H.

    2013-12-01

    Accelerator Mass Spectrometry (AMS) has been established as the best-suited radiocarbon detection technique. In the past years, significant progress with AMS instrumentation has been made resulting in a boom of new AMS facilities around the World. Today, carbon only AMS systems predominantly utilize 1+ charge state and molecule destruction in multiple ion gas collisions in stripper gas cell. This has made possible a significant simplification of the instruments, a reduction of ion energies and related to this less required space of the installations. However, state-of-the-art AMS instruments have still not reached a development stage where they can be regarded as table-top systems. In this respect, more development is needed to further advance the applicability of radiocarbon not only in the traditional fields of dating but also in biomedical research and new fields in Earth and environmental sciences. In a the proof-of-principle experiment the feasibility of radiocarbon detection over the entire range of dating applications was demonstrated using a pure mass spectrometer and ion energies below 50 keV. Now an experimental platform has been completed to test performance and to explore operation and measurement conditions of pure mass spectrometric radiocarbon detection. This contribution will overview the physical principles, which make this development possible and discuss key parameters of the instrumental design and performance of such an instrument.

  11. Low-Dimensional Feature Representation for Instrument Identification

    Science.gov (United States)

    Ihara, Mizuki; Maeda, Shin-Ichi; Ikeda, Kazushi; Ishii, Shin

    For monophonic music instrument identification, various feature extraction and selection methods have been proposed. One of the issues toward instrument identification is that the same spectrum is not always observed even in the same instrument due to the difference of the recording condition. Therefore, it is important to find non-redundant instrument-specific features that maintain information essential for high-quality instrument identification to apply them to various instrumental music analyses. For such a dimensionality reduction method, the authors propose the utilization of linear projection methods: local Fisher discriminant analysis (LFDA) and LFDA combined with principal component analysis (PCA). After experimentally clarifying that raw power spectra are actually good for instrument classification, the authors reduced the feature dimensionality by LFDA or by PCA followed by LFDA (PCA-LFDA). The reduced features achieved reasonably high identification performance that was comparable or higher than those by the power spectra and those achieved by other existing studies. These results demonstrated that our LFDA and PCA-LFDA can successfully extract low-dimensional instrument features that maintain the characteristic information of the instruments.

  12. Proceedings: Electromagnetic interference control in modern digital instrumentation and control upgrades

    International Nuclear Information System (INIS)

    1993-06-01

    A workshop on Electro-Magnetic Interference (EMI) Control in Modern Digital Instrumentation ampersand Control System Upgrade was held in Baltimore on September 10-11, 1992 to provide a forum for technology transfer, technical information exchange, and education. The workshop was attended by more than 70 representatives of electric utilities, equipment manufacturers, engineering consulting organizations, and government agencies. The workshop consists of four sessions: (1) Organizational EMC Perspectives, (2) EMI Environment, Case Histories ampersand Solutions, (3) EMC in Digital Instrumentation ampersand Control Systems, and (4) EMI Utility Needs. A group discussion followed the presentations to identify utility needs. Individual papers have been cataloged separately

  13. Instrumental analysis of bacterial cells using vibrational and emission Moessbauer spectroscopic techniques

    International Nuclear Information System (INIS)

    Kamnev, Alexander A.; Tugarova, Anna V.; Antonyuk, Lyudmila P.; Tarantilis, Petros A.; Kulikov, Leonid A.; Perfiliev, Yurii D.; Polissiou, Moschos G.; Gardiner, Philip H.E.

    2006-01-01

    In biosciences and biotechnology, the expanding application of physicochemical approaches using modern instrumental techniques is an efficient strategy to obtain valuable and often unique information at the molecular level. In this work, we applied a combination of vibrational (Fourier transform infrared (FTIR), FT-Raman) spectroscopic techniques, useful in overall structural and compositional analysis of bacterial cells of the rhizobacterium Azospirillum brasilense, with 57 Co emission Moessbauer spectroscopy (EMS) used for sensitive monitoring of metal binding and further transformations in live bacterial cells. The information obtained, together with ICP-MS analyses for metals taken up by the bacteria, is useful in analysing the impact of the environmental conditions (heavy metal stress) on the bacterial metabolism and some differences in the heavy metal stress-induced behaviour of non-endophytic (Sp7) and facultatively endophytic (Sp245) strains. The results show that, while both strains Sp7 and Sp245 take up noticeable and comparable amounts of heavy metals from the medium (0.12 and 0.13 mg Co, 0.48 and 0.44 mg Cu or 4.2 and 2.1 mg Zn per gram of dry biomass, respectively, at a metal concentration of 0.2 mM in the medium), their metabolic responses differ essentially. Whereas for strain Sp7 the FTIR measurements showed significant accumulation of polyhydroxyalkanoates as storage materials involved in stress endurance, strain Sp245 did not show any major changes in cellular composition. Nevertheless, EMS measurements showed rapid binding of cobalt(II) by live bacterial cells (chemically similar to metal binding by dead bacteria) and its further transformation in the live cells within an hour

  14. Instrumental analysis of bacterial cells using vibrational and emission Moessbauer spectroscopic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kamnev, Alexander A. [Laboratory of Biochemistry of Plant-Bacterial Symbioses, Institute of Biochemistry and Physiology of Plants and Microorganisms, Russian Academy of Sciences, 410049 Saratov (Russian Federation)]. E-mail: aakamnev@ibppm.sgu.ru; Tugarova, Anna V. [Laboratory of Biochemistry of Plant-Bacterial Symbioses, Institute of Biochemistry and Physiology of Plants and Microorganisms, Russian Academy of Sciences, 410049 Saratov (Russian Federation); Antonyuk, Lyudmila P. [Laboratory of Biochemistry of Plant-Bacterial Symbioses, Institute of Biochemistry and Physiology of Plants and Microorganisms, Russian Academy of Sciences, 410049 Saratov (Russian Federation); Tarantilis, Petros A. [Laboratory of Chemistry, Department of Science, Agricultural University of Athens, 11855 Athens (Greece); Kulikov, Leonid A. [Laboratory of Nuclear Chemistry Techniques, Department of Radiochemistry, Faculty of Chemistry, M.V. Lomonosov Moscow State University, 119992 Moscow (Russian Federation); Perfiliev, Yurii D. [Laboratory of Nuclear Chemistry Techniques, Department of Radiochemistry, Faculty of Chemistry, M.V. Lomonosov Moscow State University, 119992 Moscow (Russian Federation); Polissiou, Moschos G. [Laboratory of Chemistry, Department of Science, Agricultural University of Athens, 11855 Athens (Greece); Gardiner, Philip H.E. [Division of Chemistry, School of Science and Mathematics, Sheffield Hallam University, Sheffield S1 1WB (United Kingdom)

    2006-07-28

    In biosciences and biotechnology, the expanding application of physicochemical approaches using modern instrumental techniques is an efficient strategy to obtain valuable and often unique information at the molecular level. In this work, we applied a combination of vibrational (Fourier transform infrared (FTIR), FT-Raman) spectroscopic techniques, useful in overall structural and compositional analysis of bacterial cells of the rhizobacterium Azospirillum brasilense, with {sup 57}Co emission Moessbauer spectroscopy (EMS) used for sensitive monitoring of metal binding and further transformations in live bacterial cells. The information obtained, together with ICP-MS analyses for metals taken up by the bacteria, is useful in analysing the impact of the environmental conditions (heavy metal stress) on the bacterial metabolism and some differences in the heavy metal stress-induced behaviour of non-endophytic (Sp7) and facultatively endophytic (Sp245) strains. The results show that, while both strains Sp7 and Sp245 take up noticeable and comparable amounts of heavy metals from the medium (0.12 and 0.13 mg Co, 0.48 and 0.44 mg Cu or 4.2 and 2.1 mg Zn per gram of dry biomass, respectively, at a metal concentration of 0.2 mM in the medium), their metabolic responses differ essentially. Whereas for strain Sp7 the FTIR measurements showed significant accumulation of polyhydroxyalkanoates as storage materials involved in stress endurance, strain Sp245 did not show any major changes in cellular composition. Nevertheless, EMS measurements showed rapid binding of cobalt(II) by live bacterial cells (chemically similar to metal binding by dead bacteria) and its further transformation in the live cells within an hour.

  15. Characterization of a catalyst-based conversion technique to measure total particulate nitrogen and organic carbon and comparison to a particle mass measurement instrument

    Science.gov (United States)

    Stockwell, Chelsea E.; Kupc, Agnieszka; Witkowski, Bartłomiej; Talukdar, Ranajit K.; Liu, Yong; Selimovic, Vanessa; Zarzana, Kyle J.; Sekimoto, Kanako; Warneke, Carsten; Washenfelder, Rebecca A.; Yokelson, Robert J.; Middlebrook, Ann M.; Roberts, James M.

    2018-05-01

    electrospray ionization source of a quadrupole mass spectrometer (PILS-ESI/MS) sampling in the negative-ion mode. We obtain excellent correlations (R2 = 0.99) of particle mass measured as Nr with PILS-ESI/MS measurements converted to the corresponding particle anion mass (e.g., nitrate, sulfate, and chloride). The Nr and PILS-ESI/MS are shown to agree to within ˜ 6 % for particle mass loadings of up to 120 µg m-3. Consideration of all the sources of error in the PILS-ESI/MS technique yields an overall uncertainty of ±20 % for these single-component particle streams. These results demonstrate the Nr system is a reliable direct particle mass measurement technique that differs from other particle instrument calibration techniques that rely on knowledge of particle size, shape, density, and refractive index.

  16. Comparison of SANS instruments at reactors and pulsed sources

    International Nuclear Information System (INIS)

    Thiyagarajan, P.; Epperson, J.E.; Crawford, R.K.; Carpenter, J.M.; Hjelm, R.P. Jr.

    1992-01-01

    Small angle neutron scattering is a general purpose technique to study long range fluctuations and hence has been applied in almost every field of science for material characterization. SANS instruments can be built at steady state reactors and at the pulsed neutron sources where time-of-flight (TOF) techniques are used. The steady state instruments usually give data over small q ranges and in order to cover a large q range these instruments have to be reconfigured several times and SANS measurements have to be made. These instruments have provided better resolution and higher data rates within their restricted q ranges until now, but the TOF instruments are now developing to comparable performance. The TOF-SANS instruments, by using a wide band of wavelengths, can cover a wide dynamic q range in a single measurement. This is a big advantage for studying systems that are changing and those which cannot be exactly reproduced. This paper compares the design concepts and performances of these two types of instruments

  17. The Effect of the SCAMPER Technique in Raising Awareness Regarding the Collection and Utilization of Solid Waste

    Science.gov (United States)

    Çelikler, Dilek; Harman, Gonca

    2015-01-01

    The aim of this study was to determine the effect of the SCAMPER technique in raising awareness among science students regarding the collection and utilization of solid waste. The participants included a total of 65 third-year students. According to the study results, the science students described schools and visual media as their main source of…

  18. The 2007 ESO Instrument Calibration Workshop

    CERN Document Server

    Kaufer, Andreas; ESO Workshop

    2008-01-01

    The 2007 ESO Instrument Calibration workshop brought together more than 120 participants with the objective to a) foster the sharing of information, experience and techniques between observers, instrument developers and instrument operation teams, b) review the actual precision and limitations of the applied instrument calibration plans, and c) collect the current and future requirements by the ESO users. These present proceedings include the majority of the workshop’s contributions and document the status quo of instrument calibration at ESO in large detail. Topics covered are: Optical Spectro-Imagers, Optical Multi-Object Spectrographs, NIR and MIR Spectro-Imagers, High-Resolution Spectrographs, Integral Field Spectrographs, Adaptive Optics Instruments, Polarimetric Instruments, Wide Field Imagers, Interferometric Instruments as well as other crucial aspects such as data flow, quality control, data reduction software and atmospheric effects. It was stated in the workshop that "calibration is a life-long l...

  19. The sliding rail system (monorail): description of a new technique for intravascular instrumentation and its application to coronary angioplasty.

    Science.gov (United States)

    Bonzel, T; Wollschläger, H; Kasper, W; Meinertz, T; Just, H

    1987-01-01

    The sliding rail technique is a new technique for intravascular instrumentation, especially coronary stenosis dilatation. The so-called monorail balloon catheter is the first device which can be used according to this technique. The monorail catheter has a single lumen shaft and only a short central tube within the distal balloon part. With the guidewire inserted into the tube, the balloon can be advanced or retracted on the guidewire as on a sliding rail. The most relevant improvements for coronary dilatation are steerability, contrast flow and rapid and easy exchangeability of balloon catheters and other intracoronary devices. These characteristics are felt to result in a more simple and time- and fluoroscopy-saving dilatation procedure. A special transfusion catheter may also improve procedural safety. The first clinical results in 69 patients with a success rate of 96%, an emergency bypass rate of two patients (one infarction) and a stenosis improvement of 58% confirm the theoretically conceived advantages.

  20. Providing nuclear reactor control information in the presence of instrument failures

    International Nuclear Information System (INIS)

    Tylee, J.L.; Purviance, J.E.

    1986-01-01

    A technique for using unfailed instrument outputs to generate optimal estimates of failed sensor outputs is presented and evaluated. The technique uses a bank of discrete, linear Kalman filters, each dedicated to one instrument, and a combinatory logic to perform the output estimation. The technique is tested using measurement data from a university research reactor

  1. Cross-cultural adaptation of instruments assessing breastfeeding determinants: a multi-step approach

    Science.gov (United States)

    2014-01-01

    Background Cross-cultural adaptation is a necessary process to effectively use existing instruments in other cultural and language settings. The process of cross-culturally adapting, including translation, of existing instruments is considered a critical set to establishing a meaningful instrument for use in another setting. Using a multi-step approach is considered best practice in achieving cultural and semantic equivalence of the adapted version. We aimed to ensure the content validity of our instruments in the cultural context of KwaZulu-Natal, South Africa. Methods The Iowa Infant Feeding Attitudes Scale, Breastfeeding Self-Efficacy Scale-Short Form and additional items comprise our consolidated instrument, which was cross-culturally adapted utilizing a multi-step approach during August 2012. Cross-cultural adaptation was achieved through steps to maintain content validity and attain semantic equivalence in the target version. Specifically, Lynn’s recommendation to apply an item-level content validity index score was followed. The revised instrument was translated and back-translated. To ensure semantic equivalence, Brislin’s back-translation approach was utilized followed by the committee review to address any discrepancies that emerged from translation. Results Our consolidated instrument was adapted to be culturally relevant and translated to yield more reliable and valid results for use in our larger research study to measure infant feeding determinants effectively in our target cultural context. Conclusions Undertaking rigorous steps to effectively ensure cross-cultural adaptation increases our confidence that the conclusions we make based on our self-report instrument(s) will be stronger. In this way, our aim to achieve strong cross-cultural adaptation of our consolidated instruments was achieved while also providing a clear framework for other researchers choosing to utilize existing instruments for work in other cultural, geographic and population

  2. Tritium instrumentation for a fusion reactor power plant

    International Nuclear Information System (INIS)

    Shank, K.E.; Easterly, C.E.

    1976-09-01

    A review of tritium instrumentation is presented. This includes a discussion of currently available in-plant instrumentation and methods required for sampling stacks, monitoring process streams and reactor coolants, analyzing occupational work areas for air and surface contamination, and personnel monitoring. Off-site instrumentation and collection techniques are also presented. Conclusions are made concerning the adequacy of existing instrumentation in relation to the monitoring needs for fusion reactors

  3. Proceedings of national symposium on advanced instrumentation for nuclear research

    International Nuclear Information System (INIS)

    1993-01-01

    The National Symposium on Advanced Instrumentation for Nuclear Research was held in Bombay during January 27-29, 1993 at BARC. Progress of modern nuclear research is closely related to the availability of state of the art instruments and systems. With the advancements in experimental techniques and sophisticated detector developments, the performance specifications have become more stringent. State of the art techniques and diverse applications of sophisticated nuclear instrumentation systems are discussed along with indigenous efforts to meet the specific instrumentation needs of research programs in nuclear sciences. Papers of relevance to nuclear science and technology are indexed separately. (original)

  4. Development of intelligent system for a thermal analysis instrument

    International Nuclear Information System (INIS)

    Xu Xiaoli; Wu Guoxin; Shi Yongchao

    2005-01-01

    The key techniques for the intelligent analysis instrument developed are proposed. Based on the technique of virtual instrumentation, the intelligent PID control algorithm to control the temperature of thermal analysis instrument is described. The dynamic character and the robust performance of traditional PID controls are improved through the dynamic gain factor, temperature rate change factor, the forecast factor, and the temperature correction factor is introduced. Using the graphic development environment of LabVIEW, the design of system modularization and the graphic display are implemented. By means of multiple mathematical modules, intelligent data processing is realized

  5. Proceedings of symposium on intelligent nuclear instrumentation-2001

    International Nuclear Information System (INIS)

    Kataria, S.K.; Vaidya, P.P.; Das, Debashis; Narurkar, P.V.

    2001-02-01

    Advances in the field of instrumentation are relevant to many areas of importance such as nuclear and accelerator based research, reactor monitoring and control, non-destructive testing and evaluation, laser programme and health and environment monitoring etc. The nuclear instrumentation is a specialized field with very specific expertise in detection, processing and its analysis. The symposium covers various fields of nuclear interest such as radiation detectors, application of ASICs and FPGA in instruments, field instruments, nuclear instrumentation for basic research, accelerator, reactor, health and environmental monitoring instrumentation, medical instrumentation, instrument net working inclusive of field buses, WEB based and wireless technologies, software tools, AI technique in instrumentation etc., in this specialized area. Papers relevant to INIS are indexed separately

  6. Neutron diagnostics on TFTR utilizing the Campbelling technique

    International Nuclear Information System (INIS)

    England, A.C.; Hendel, H.W.; Neischmidt, E.B.

    1986-01-01

    The authors report modified commercial neutron counting equipment installed on a tokamak fusion test reactor (TFTR) which utilizes the Campbelling theorem to monitor the neutron source strength at very high neutron count rates. Campbelling utilizes the large amplitude fluctuation from neutron events in the detectors to discriminate against small amplitude noise events. Source strengths yielding equivalent count rates a factor of five higher than possible in the conventional count rate mode have been obtained to date. The concept of Campbelling is discussed and the particular application to TFTR is illustrated

  7. Instrumentation in elementary particle physics

    Energy Technology Data Exchange (ETDEWEB)

    Fabjan, C W [European Organization for Nuclear Research, Geneva (Switzerland); Pilcher, J E [Chicago Univ., IL (United States); eds.

    1988-01-01

    The first International Committee for Future Accelerators Instrumentation School was held at the International Centre for Theoretical Physics, Trieste, Italy from 8 to 19 June 1987. The School was attended by 74 students of whom 45 were from developing countries, 10 lecturers and 9 laboratory instructors. The next generation of elementary particle physics experiments would depend vitally on new ideas in instrumentation. This is a field where creativity and imagination play a major role and large budgets are not a prerequisite. One of the unique features was the presentation of four laboratory experiments using modern techniques and instrumentation. Refs, figs and tabs.

  8. Instrumentation in elementary particle physics

    International Nuclear Information System (INIS)

    Fabjan, C.W.; Pilcher, J.E.

    1988-01-01

    The first International Committee for Future Accelerators Instrumentation School was held at the International Centre for Theoretical Physics, Trieste, Italy from 8 to 19 June 1987. The School was attended by 74 students of whom 45 were from developing countries, 10 lecturers and 9 laboratory instructors. The next generation of elementary particle physics experiments would depend vitally on new ideas in instrumentation. This is a field where creativity and imagination play a major role and large budgets are not a prerequisite. One of the unique features was the presentation of four laboratory experiments using modern techniques and instrumentation. Refs, figs and tabs

  9. Instrumental methods of analysis, 7th edition

    International Nuclear Information System (INIS)

    Willard, H.H.; Merritt, L.L. Jr.; Dean, J.A.; Settle, F.A. Jr.

    1988-01-01

    The authors have prepared an organized and generally polished product. The book is fashioned to be used as a textbook for an undergraduate instrumental analysis course, a supporting textbook for graduate-level courses, and a general reference work on analytical instrumentation and techniques for professional chemists. Four major areas are emphasized: data collection and processing, spectroscopic instrumentation and methods, liquid and gas chromatographic methods, and electrochemical methods. Analytical instrumentation and methods have been updated, and a thorough citation of pertinent recent literature is included

  10. New technology in nuclear power plant instrumentation and control

    International Nuclear Information System (INIS)

    Anon.

    1985-01-01

    The primary topic of this book is what can be done to improve nuclear power plant operation safety and the economic benefits that can be gained with the utilization of advance instrumentation and control technology. Other topics discussed are the industry's reluctance to accept new designs determining cost effective improvements, and difficulties in meeting regulatory standards with new technology control. The subjects will be useful when considering the area of instrumentation and control for enhancing plant operation and safety. Contents: Advanced Instrumention, Plant Control and Monitoring, Plant Diagnostics and Failure Detection, Human Factors Considerations in Instrumentation and Control, NRC and Industry Perspective on Advanced Instrumentation and Control

  11. Utilization technique on variable speed device

    International Nuclear Information System (INIS)

    1989-12-01

    This reports of workshop on power technology describes using technique on variable speed device, which deals with alternating current situation and prospect of current variable speed device, technical trend and prospect of electronics, reduce expenses by variable speed device, control technique, measurement technology, high voltage variable speed device, recent trend of inverter technology, low voltage and high voltage variable speed device control device, operating variable speed device in cooling fan, FDF application and defect case of variable speed device, cooling pump application of water variable transformer, inverter application and energy effect of ventilation equipment, application of variable speed device and analysis of the result of operation and study for application of variable speed technology.

  12. About the parametrizations utilized to perform magnetic moments measurements using the transient field technique

    Energy Technology Data Exchange (ETDEWEB)

    Gómez, A. M., E-mail: amgomezl-1@uqvirtual.edu.co [Programa de Física, Universidad del Quindo (Colombia); Torres, D. A., E-mail: datorresg@unal.edu.co [Physics Department, Universidad Nacional de Colombia, Bogotá (Colombia)

    2016-07-07

    The experimental study of nuclear magnetic moments, using the Transient Field technique, makes use of spin-orbit hyperfine interactions to generate strong magnetic fields, above the kilo-Tesla regime, capable to create a precession of the nuclear spin. A theoretical description of such magnetic fields is still under theoretical research, and the use of parametrizations is still a common way to address the lack of theoretical information. In this contribution, a review of the main parametrizations utilized in the measurements of Nuclear Magnetic Moments will be presented, the challenges to create a theoretical description from first principles will be discussed.

  13. Virtual experiment instrument of nuclear pulse measuring

    International Nuclear Information System (INIS)

    Shan Jian; Zhao Xiuliang; Yu Hong; Zhang Meiqin

    2009-01-01

    Study on the scheme of application of virtual instrument(VI) technique in measuring of nuclear pulse. The system of Counter based on technology of LabVIEW and NI company's products USB-6009-DAQ is developed. Virtual nuclear instrument-Virtual Counter is realized. This system extends the application of technology of virtual instrument. The experimental results indicate that the system of Counter had the good counting measuring function of Nuclear Pulse. (authors)

  14. Data acquisition instruments: Psychopharmacology

    Energy Technology Data Exchange (ETDEWEB)

    Hartley, D.S. III

    1998-01-01

    This report contains the results of a Direct Assistance Project performed by Lockheed Martin Energy Systems, Inc., for Dr. K. O. Jobson. The purpose of the project was to perform preliminary analysis of the data acquisition instruments used in the field of psychiatry, with the goal of identifying commonalities of data and strategies for handling and using the data in the most advantageous fashion. Data acquisition instruments from 12 sources were provided by Dr. Jobson. Several commonalities were identified and a potentially useful data strategy is reported here. Analysis of the information collected for utility in performing diagnoses is recommended. In addition, further work is recommended to refine the commonalities into a directly useful computer systems structure.

  15. A comparison of instrumentation using Naviflex and Profile nickel-titanium engine-driven rotary instruments.

    Science.gov (United States)

    Ottosen, S R; Nicholls, J I; Steiner, J C

    1999-06-01

    This study was designed to compare the changes in canal configuration resulting from instrumentation by either Profile or Naviflex instruments. Forty mesial canals in extracted human molar teeth were embedded and sectioned at two root levels. Reassembled teeth were instrumented with a modified crown-down technique as described in the Profile training video for Profile files and in a similar manner for Naviflex instruments. Superimposed pre- and postinstrumented cross-sectional root images were projected, traced, and scanned into a computer for analysis. Canal movement, in relation to the furca, and canal area change were recorded. The results showed no significant difference in canal center movement or canal area change between the Profile or Naviflex groups. The degree of canal curvature had no effect on canal center movement or canal area change.

  16. Health physics instruments: what are the current needs

    International Nuclear Information System (INIS)

    Armantrout, G.A.

    1982-01-01

    Health Physics instruments are used to measure the risk which may be incurred by an individual exposed to a given radiation field. The response of the instrument sensors will differ markedly from actual human risk factors for a variety of reasons, and this requires the use of instrument modifications and conversion factors. The values of these conversion factors continue to be updated and will likely change in the future. To accommodate the effects of different types of radiation and new conversion and usage factors, new instruments should be able to determine the type, energy distribution, and direction of incoming radiation and then apply the proper weighting factors to determine relative human risk. Such instrumentation will need to utilize modern sensor elements and microprocessor electronics

  17. Instrumentation for Air Pollution Monitoring

    Science.gov (United States)

    Hollowell, Craig D.; McLaughlin, Ralph D.

    1973-01-01

    Describes the techniques which form the basis of current commercial instrumentation for monitoring five major gaseous atmospheric pollutants (sulfur dioxide, oxides of nitrogen, oxidants, carbon monoxide, and hydrocarbons). (JR)

  18. The utilization of irradiation techniques in food industry

    International Nuclear Information System (INIS)

    Szabo, S.A.

    1988-01-01

    Irradiation technical researches and the main areas of nuclear technical applications are surveyed, and the main areas where nuclear techniques are used are reported. Then an overview on radiation techniques including radiostimulation, radiomutation, radurization, radioecology and isotope techniques used in the food industry is presented. (author) 4 refs

  19. Actinide recovery techniques utilizing electromechanical processes

    International Nuclear Information System (INIS)

    Westphal, B.R.; Benedict, R.W.

    1994-01-01

    Under certain conditions, the separation of actinides using electromechanical techniques may be an effective means of residue processing. The separation of granular mixtures of actinides and other materials is based on appreciable differences in the magnetic and electrical properties of the actinide elements. In addition, the high density of actinides, particularly uranium and plutonium, may render a simultaneous separation based on mutually complementary parameters. Both high intensity magnetic separation and electrostatic separation have been investigated for the concentration of an actinide waste stream. Waste stream constituents include an actinide metal alloy and broken quartz shards. The investigation of these techniques is in support of the Integral Fast Reactor (IFR) concept currently being developed at Argonne National Laboratory under the auspices of the Department of Energy

  20. Surveillance of instruments by noise analysis

    International Nuclear Information System (INIS)

    Thie, J.A.

    1981-01-01

    Random fluctuations of neutron flux, temperature, and pressure in a reactor provide multifrequency excitation of the corresponding instrumentation chains. Mathematical descriptors suitable for characterizing the output, or noise, of the instrumentation are reviewed with a view toward using such noise in detecting instrument faults. Demonstrations of the feasibility of this approach in a number of reactors provide illustrative examples. Comparisons with traditional surveillance testing are made, and a number of advantages and some disadvantages of using noise analysis as a supplementary technique are pointed out

  1. Instrumental analysis, second edition

    International Nuclear Information System (INIS)

    Christian, G.D.; O'Reilly, J.E.

    1988-01-01

    The second edition of Instrumental Analysis is a survey of the major instrument-based methods of chemical analysis. It appears to be aimed at undergraduates but would be equally useful in a graduate course. The volume explores all of the classical quantitative methods and contains sections on techniques that usually are not included in a semester course in instrumentation (such as electron spectroscopy and the kinetic methods). Adequate coverage of all of the methods contained in this book would require several semesters of focused study. The 25 chapters were written by different authors, yet the style throughout the book is more uniform than in the earlier edition. With the exception of a two-chapter course in analog and digital circuits, the book purports to de-emphasize instrumentation, focusing more on the theory behind the methods and the application of the methods to analytical problems. However, a detailed analysis of the instruments used in each method is by no means absent. The book has the favor of a user's guide to analysis

  2. Development of an instrument for measuring moisture deep into solid materials

    International Nuclear Information System (INIS)

    Westin, R.; Walletun, H.

    1993-01-01

    It is of value in some applications to be able to detect humidity rather deep into a solid material, for example when determining the moisture content in the frame of buildings, in insulation or in biofuels. Common to these measurement problems is that it is difficult to measure moisture in the bulk of a solid, in contrast to the surface layers. In this report is described the principle and the functioning of an instrument to measure moisture at larger depths than other instruments that are available today. It is intended for use primarily on solid materials, not on gases or liquids. Field experience is also reported here. The principle of the measuring technique is nuclear: we have utilized the ability of hydrogen atoms to moderate (or brake) high energy neutrons. If there is hydrogen in the sample, fast neutrons will interact with the hydrogen atoms and one may detect and count low energy, so called thermal neutrons. The intensity of the slow neutron flux is proportional to the water content, if one assumes that hydrogen atoms are water, i.e. moisture

  3. Discrete-time modelling of musical instruments

    International Nuclear Information System (INIS)

    Vaelimaeki, Vesa; Pakarinen, Jyri; Erkut, Cumhur; Karjalainen, Matti

    2006-01-01

    This article describes physical modelling techniques that can be used for simulating musical instruments. The methods are closely related to digital signal processing. They discretize the system with respect to time, because the aim is to run the simulation using a computer. The physics-based modelling methods can be classified as mass-spring, modal, wave digital, finite difference, digital waveguide and source-filter models. We present the basic theory and a discussion on possible extensions for each modelling technique. For some methods, a simple model example is chosen from the existing literature demonstrating a typical use of the method. For instance, in the case of the digital waveguide modelling technique a vibrating string model is discussed, and in the case of the wave digital filter technique we present a classical piano hammer model. We tackle some nonlinear and time-varying models and include new results on the digital waveguide modelling of a nonlinear string. Current trends and future directions in physical modelling of musical instruments are discussed

  4. The utility of neuroimaging in the management of dementia

    Directory of Open Access Journals (Sweden)

    Uduak E Williams

    2015-01-01

    Full Text Available Dementia is a syndrome of progressive dysfunction of two or more cognitive domains associated with impairment of activities of daily living. An understanding of the pathophysiology of dementia and its early diagnosis is important in the pursuit of possible disease modifying therapy for dementia. Neuroimaging has greatly transformed this field of research as its function has changed from a mere tool for diagnosing treatable causes of dementia to an instrument for pre-symptomatic diagnosis of dementia. This review focuses on the diagnostic utility of neuroimaging in the management of progressive dementias. Structural imaging techniques like computerized tomography scan and magnetic resonance imaging highlights the anatomical, structural and volumetric details of the brain; while functional imaging techniques such as positron emission tomography, arterial spin labeling, single photon emission computerized tomography and blood oxygen level-dependent functional magnetic resonance imaging focuses on chemistry, circulatory status and physiology of the different brain structures and regions.

  5. The Overtone Fiddle: an Actuated Acoustic Instrument

    DEFF Research Database (Denmark)

    Overholt, Daniel

    2011-01-01

    both traditional violin techniques, as well as extended playing techniques that incorporate shared man/machine control of the resulting sound. A magnetic pickup system is mounted to the end of the fiddle’s fingerboard in order to detect the signals from the vibrating strings, deliberately not capturing...... vibrations from the full body of the instrument. This focused sensing approach allows less restrained use of DSP-generated feedback signals, as there is very little direct leakage from the actuator embedded in the body of the instrument back to the pickup....

  6. Optical inspection techniques for security instrumentation

    Science.gov (United States)

    van Renesse, Rudolf L.

    1996-03-01

    This paper reviews four optical inspection systems, in which development TNO Institute of Applied Physics was involved: (1) intaglio scanning and recognition, (2) banknote quality inspection, (3) visualization and reading of a finger pattern, and (4) 3DAS authentication. (1) Intaglio is reserved for high security printing. It renders a tactile relief that can be recognized by a laser scanning technique. This technique is applied by various national banks to detect counterfeit banknotes returning from circulation. A new system is proposed that will detect intaglio on arbitrary wrinkled banknotes. (2) A banknote fitness inspection system (BFIS) that inspects banknotes in specularly reflected light is described. As modern banknotes are provided increasingly with reflective security foils, a new system is proposed that inspects banknotes in specular and diffuse reflection, as well as in transmission. (3) An alternative visualization method for visualization of finger patterns is described, employing a reflective elastomer. A CD scanning system reads the finger patterns. (4) A nonwoven structure has two advantageous properties for card authentication: a random structure which renders each few square millimeters of the pattern uniqueness (identification) and a 3D structure which makes it virtually impossible to be counterfeited (authentication). Both properties are inspected by an extremely simple lenseless reader.

  7. Developing of Individual Instrument Performance Anxiety Scale: ValidityReliability Study

    Directory of Open Access Journals (Sweden)

    Esra DALKIRAN

    2016-07-01

    Full Text Available In this study, it is intended to develop a scale unique to our culture, concerning individual instrument performance anxiety of the students who are getting instrument training in the Department of Music Education. In the study, the descriptive research model is used and qualitative research techniques are utilized. The study population consists of the students attending the 23 universities which has Music Education Department. The sample of the study consists of 438 girls and 312 boys, totally 750 students who are studying in the Department of Music Education of randomly selected 10 universities. As a result of the explanatory and confirmatory factor analyses that were performed, a onedimensional structure consisting of 14 items was obtained. Also, t-scores and the coefficient scores of total item correlation concerning the distinguishing power of the items, the difference in the scores of the set of lower and upper 27% was calculated, and it was observed that the items are distinguishing as a result of both analyses. Of the scale, Cronbach's alpha coefficient of internal consistency was calculated as .94, and test-retest reliability coefficient was calculated as .93. As a result, a valid and reliable assessment and evaluation instrument that measures the exam performance anxiety of the students studying in the Department of Music Education, has been developed.

  8. Legal instruments for the promotion of a sustainable consumption. Using products as an example; Rechtliche Instrumente zur Foerderung des nachhaltigen Konsums. Am Beispiel von Produkten

    Energy Technology Data Exchange (ETDEWEB)

    Schlacke, Sabine; Stadermann, Michael; Grunow, Moritz [Forschungsstelle fuer Europaeisches Umweltrecht (FEU), Bremen (Germany)

    2012-06-15

    The expertise under consideration attempts to identify, to analyze and to develop further the legal instruments for the promotion of asustainable consumption. Legal possibilities of impacting the consumer behaviour in the utilization phase of products shall be highlighted in order to promote the sustainable consumption. The focus of this expertise are instruments directly aimed at consumers. The activation of these instruments shall effectuate a more sustainable behaviour of consumption.

  9. Survey of beam instrumentation used in SLC

    International Nuclear Information System (INIS)

    Ecklund, S.D.

    1991-03-01

    A survey of beam instruments used at SLAC in the SLC machine is presented. The basic utility and operation of each device is briefly described. The various beam instruments used at the Stanford Linear Collider (SLC), can be classified by the function they perform. Beam intensity, position and size are typical of the parameters of beam which are measured. Each type of parameter is important for adjusting or tuning the machine in order to achieve optimum performance. 39 refs

  10. Actinide recovery techniques utilizing electromechanical processes

    International Nuclear Information System (INIS)

    Westphal, B.R.; Benedict, R.W.

    1994-01-01

    Under certain conditions, the separation of actinides using electromechanical techniques may be an effective means of residue processing. The separation of granular mixtures of actinides and other materials discussed in this report is based on appreciable differences in the magnetic and electrical properties of the actinide elements. In addition, the high density of actinides, particularly uranium and plutonium, may render a simultaneous separation based on mutually complementary parameters. Both high intensity magnetic separation and electrostatic separation have been investigated for the concentration of an actinide waste stream. Waste stream constituents include an actinide metal alloy and broken quartz shards. The investigation of these techniques is in support of the Integral Fast Reactor (IFR) concept currently being developed at Argonne National Laboratory under the auspices of the Department of Energy

  11. ALADIN - Advanced Laue Diffraction Instruments using Neutrons

    International Nuclear Information System (INIS)

    Lemee-Cailleau, M.H.; Ouladdiaf, B.; McIntyre, G.J.

    2011-01-01

    Laue diffraction techniques have proven to be very attractive to a broad user community interested in obtaining detailed structural information on very small single-crystal samples or needing data collection speeds comparable to those available with the powder diffraction technique. However our experience has clearly demonstrated the negative effect of up-stream monochromatic instruments on the quality of Laue data. In order to obtain Laue diffraction data with a statistical accuracy similar to that achieved on a monochromatic instrument (neutron or X-rays), the project ALADIN (for Advanced Laue Diffraction Instruments using Neutrons) aims to: -) construct a Laue-dedicated thermal neutron guide, with m=2 super-mirror coating, providing access to the desirable wavelength bandwidth; -) installation of one of the ILL Laue diffractometers (VIVALDI or CYCLOPS) on this new guide. (authors)

  12. Development of fault diagnostic technique using reactor noise analysis

    International Nuclear Information System (INIS)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B.

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  13. Development of fault diagnostic technique using reactor noise analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  14. Falsification Testing of Instrumental Variables Methods for Comparative Effectiveness Research.

    Science.gov (United States)

    Pizer, Steven D

    2016-04-01

    To demonstrate how falsification tests can be used to evaluate instrumental variables methods applicable to a wide variety of comparative effectiveness research questions. Brief conceptual review of instrumental variables and falsification testing principles and techniques accompanied by an empirical application. Sample STATA code related to the empirical application is provided in the Appendix. Comparative long-term risks of sulfonylureas and thiazolidinediones for management of type 2 diabetes. Outcomes include mortality and hospitalization for an ambulatory care-sensitive condition. Prescribing pattern variations are used as instrumental variables. Falsification testing is an easily computed and powerful way to evaluate the validity of the key assumption underlying instrumental variables analysis. If falsification tests are used, instrumental variables techniques can help answer a multitude of important clinical questions. © Health Research and Educational Trust.

  15. Applicability of analytical instrument in trace evidence analysis

    International Nuclear Information System (INIS)

    Sharma, Mukesh; Jha, Shailendra

    2014-01-01

    In the present paper, we explain the importance of the analytical instrument used in the field of forensic science for the analysis of the trace evidences collected from the scene of occurrence. The forensic scientist has to rely upon these instrumental analyses of trace amounts of materials like drugs, toxicological specimens, GSR, fibres, glass, paints, soil etc. Through this paper, reviews on these techniques which are extensively used in forensic sciences are reported. Our report summaries on the basis of analytical problem facing for a forensic expert and techniques employed to tackle them like XRD/XRF, inductively coupled plasma (ICP) techniques, Raman spectroscopy and microscopy (optical, GRIM, electron microscopy, TEM). (author)

  16. Increasing Laser Stability with Improved Electronic Instruments

    Science.gov (United States)

    Troxel, Daylin; Bennett, Aaron; Erickson, Christopher J.; Jones, Tyler; Durfee, Dallin S.

    2010-03-01

    We present several electronic instruments developed to implement an ultra-stable laser lock. These instruments include a high speed, low noise homodyne photo-detector; an ultrahigh stability, low noise current driver with high modulation bandwidth and digital control; a high-speed, low noise PID controller; a low-noise piezo driver; and a laser diode temperature controller. We will present the theory of operation for these instruments, design and construction techniques, and essential characteristics for each device.

  17. Utilization of a photon transport code to investigate radiation therapy treatment planning quantities and techniques

    International Nuclear Information System (INIS)

    Palta, J.R.

    1981-01-01

    A versatile computer program MORSE, based on neutron and photon transport theory has been utilzed to investigate radiation therapy treatment planning quantities and techniques. A multi-energy group representation of transport equation provides a concise approach in utilizing Monte Carlo numerical techniques to multiple radiation therapy treatment planning problems. Central axis total and scattered dose distributions for homogeneous and inhomogeneous water phantoms are calculated and the correction factor for lung and bone inhomogeneities are also evaluated. Results show that Monte Carlo calculations based on multi-energy group tansport theory predict the depth dose distributions that are in good agreement with available experimental data. Central axis depth dose distributions for a bremsstrahlung spectrum from a linear accelerator is also calculated to exhibit the versatility of the computer program in handling multiple radiation therapy problems. A novel approach is undertaken to study the dosimetric properties of brachytherapy sources

  18. Comparison of three aerosol chemical characterization techniques utilizing PTR-ToF-MS: a study on freshly formed and aged biogenic SOA

    Science.gov (United States)

    Gkatzelis, Georgios I.; Tillmann, Ralf; Hohaus, Thorsten; Müller, Markus; Eichler, Philipp; Xu, Kang-Ming; Schlag, Patrick; Schmitt, Sebastian H.; Wegener, Robert; Kaminski, Martin; Holzinger, Rupert; Wisthaler, Armin; Kiendler-Scharr, Astrid

    2018-03-01

    An intercomparison of different aerosol chemical characterization techniques has been performed as part of a chamber study of biogenic secondary organic aerosol (BSOA) formation and aging at the atmosphere simulation chamber SAPHIR (Simulation of Atmospheric PHotochemistry In a large Reaction chamber). Three different aerosol sampling techniques - the aerosol collection module (ACM), the chemical analysis of aerosol online (CHARON) and the collection thermal-desorption unit (TD) were connected to proton transfer reaction time-of-flight mass spectrometers (PTR-ToF-MSs) to provide chemical characterization of the SOA. The techniques were compared among each other and to results from an aerosol mass spectrometer (AMS) and a scanning mobility particle sizer (SMPS). The experiments investigated SOA formation from the ozonolysis of β-pinene, limonene, a β-pinene-limonene mix and real plant emissions from Pinus sylvestris L. (Scots pine). The SOA was subsequently aged by photo-oxidation, except for limonene SOA, which was aged by NO3 oxidation. Despite significant differences in the aerosol collection and desorption methods of the PTR-based techniques, the determined chemical composition, i.e. the same major contributing signals, was found by all instruments for the different chemical systems studied. These signals could be attributed to known products expected from the oxidation of the examined monoterpenes. The sampling and desorption method of ACM and TD provided additional information on the volatility of individual compounds and showed relatively good agreement. Averaged over all experiments, the total aerosol mass recovery compared to an SMPS varied within 80 ± 10, 51 ± 5 and 27 ± 3 % for CHARON, ACM and TD, respectively. Comparison to the oxygen-to-carbon ratios (O : C) obtained by AMS showed that all PTR-based techniques observed lower O : C ratios, indicating a loss of molecular oxygen either during aerosol sampling or detection. The differences in total

  19. Instrumentation techniques for studying heterogeneous combustion

    Science.gov (United States)

    Chigier, N. A.

    1977-01-01

    Velocity measurements in flames and the simultaneous measurement of droplet size and velocity with the aid of laser anemometry are considered along with methods of particle size measurement and techniques based on laser Raman spectroscopy. Attention is given to high-speed photography and holography, computer compensated thermocouples, and the determination of turbulence characteristics. The employment of suction probes is also discussed, taking into account sampling methods, the effects of temperature change in sampling probes on particle formation, and the chemical analysis of samples.

  20. Improving the accuracy of total quality management instruments.

    Science.gov (United States)

    Bechtel, G A; Wood, D

    1996-03-01

    Total quality management (TQM) instruments are essential tools in defining concepts identified in an Ishikawa or ¿cause-and-effect¿ diagram. Collecting meaningful and accurate data using TQM instruments is imperative if productivity and quality of care are to be enhanced. This article provides managers with techniques and guidelines that will enhance the reliability and validity of TQM instruments, thereby promoting organization efficiency and customer satisfaction.

  1. Instrumentation for contrast echocardiography: technology and techniques.

    Science.gov (United States)

    Kaul, Sanjiv

    2002-11-18

    Contrast echocardiography is the only clinical imaging technique in which the imaging modality (ultrasound) can cause a change in the contrast agent (microbubbles). The change in the contrast agent can range from small oscillations of the microbubbles at a low mechanical index to their disruption at a high mechanical index. The specific mechanical index required to produce these various effects may be different for each contrast agent, depending on the bubble dimension as well as shell and gas characteristics. These alterations in bubbles result in changes in ultrasound backscatter that are specific for the bubbles themselves, rather than for tissue, and are therefore exploited for imaging their presence in tissue. These signal-processing techniques have resulted in an increased signal-to-noise ratio from bubbles vis-à-vis the tissue and have made online assessment of myocardial perfusion possible.

  2. Microspectrometers: an industry and instrumentation overview

    Science.gov (United States)

    Neece, Gregory A.

    2008-08-01

    Microspectrometers, miniature spectrometers, portable spectrometers, or Fiber Optic Spectrometers are some of the names typically given to the class small spectrometers that are derived from simple, fixed optics, and low cost detector arrays. The author will use these terms interchangeably. This class of instrument has been available for over 18 years, gaining industry acceptance with each year. From a very basic optical platform to sophisticated instrumentation for scientific investigation and process control, this class of instrument has evolved substantially since its introduction to the market. For instance it is now possible to cover the range from 200 - 2,500 nm utilizing only two channels of spectrometers with either synchronous or asynchronous channel control. On board processing and memory have enabled the instruments to become fully automated, stand alone sensors communicating with their environment via analog, digital, USB2 and even wireless protocols. New detectors have entered the market enabling solutions "tuned" to the demands of specific applications.

  3. Human factors aspects of advanced instrumentation in the nuclear industry

    International Nuclear Information System (INIS)

    Carter, R.J.

    1989-01-01

    An important consideration in regards to the use of advanced instrumentation in the nuclear industry is the interface between the instrumentation system and the human. A survey, oriented towards identifying the human factors aspects of digital instrumentation, was conducted at a number of United States (US) and Canadian nuclear vendors and utilities. Human factors issues, subsumed under the categories of computer-generated displays, controls, organizational support, training, and related topics were identified. 20 refs., 2 tabs

  4. The Characterization of Biosignatures in Caves Using an Instrument Suite

    Science.gov (United States)

    Uckert, Kyle; Chanover, Nancy J.; Getty, Stephanie; Voelz, David G.; Brinckerhoff, William B.; McMillan, Nancy; Xiao, Xifeng; Boston, Penelope J.; Li, Xiang; McAdam, Amy; Glenar, David A.; Chavez, Arriana

    2017-12-01

    The search for life and habitable environments on other Solar System bodies is a major motivator for planetary exploration. Due to the difficulty and significance of detecting extant or extinct extraterrestrial life in situ, several independent measurements from multiple instrument techniques will bolster the community's confidence in making any such claim. We demonstrate the detection of subsurface biosignatures using a suite of instrument techniques including IR reflectance spectroscopy, laser-induced breakdown spectroscopy, and scanning electron microscopy/energy dispersive X-ray spectroscopy. We focus our measurements on subterranean calcium carbonate field samples, whose biosignatures are analogous to those that might be expected on some high-interest astrobiology targets. In this work, we discuss the feasibility and advantages of using each of the aforementioned instrument techniques for the in situ search for biosignatures and present results on the autonomous characterization of biosignatures using multivariate statistical analysis techniques.

  5. A new technique for promoting cyclic utilization of cyclodextrins in biotransformation.

    Science.gov (United States)

    Shen, Yanbing; Yu, Ziqi; Yang, Xu; Wang, Fang; Luo, Jianmei; Wang, Min

    2017-01-01

    Cyclodextrins (CDs) can improve the productivity of steroid biotransformation by enhancing substrate solubility. CDs can be recycled by grafting them with appropriate carriers. Loofah fiber is an excellent grafting material for CDs, and can be applied to the biotransformation and recycling of β-cyclodextrin (β-CD). In this work, a technique for recycling β-CD in cortisone acetate (CA) biotransformation by Arthrobacter simplex CPCC 140451 was studied. Loofah fiber-grafted β-CD (LF-β-CD) was prepared using epichlorohydrin, which is a cross-linking agent. The grafting yield of β-CD was 74.8 mg g -1 dried fibers. LF-β-CD could increase the solubility of CA and enhance biotransformation. The initial conversion rate of CA was 1.5-fold higher than that of the blank group. LF-β-CD was also used in biocatalytic reactions for eight cycles, and it maintained the conversion ratio of CA at approximately 90%. Given the above positive results, LF-β-CD can be utilized in biotechnological recycling applications. This method can also be applied to CD derivatives and hydrophobic compounds.

  6. Electrolytic preconcentration in instrumental analysis.

    Science.gov (United States)

    Sioda, R E; Batley, G E; Lund, W; Wang, J; Leach, S C

    1986-05-01

    The use of electrolytic deposition as a separation and preconcentration step in trace metal analysis is reviewed. Both the principles and applications of the technique are dealt with in some detail. Electrolytic preconcentration can be combined with a variety of instrumental techniques. Special attention is given to stripping voltammetry, potentiometric stripping analysis, different combinations with atomic-absorption spectrometry, and the use of flow-through porous electrodes. It is pointed out that the electrolytic preconcentration technique deserves more extensive use as well as fundamental investigation.

  7. Spectroelectrochemical Instrument Measures TOC

    Science.gov (United States)

    Kounaves, Sam

    2011-01-01

    A spectroelectrochemical instrument has been developed for measuring the total organic carbon (TOC) content of an aqueous solution. Measurements of TOC are frequently performed in environmental, clinical, and industrial settings. Until now, techniques for performing such measurements have included, various ly, the use of hazardous reagents, ultraviolet light, or ovens, to promote reactions in which the carbon contents are oxidized. The instrument now being developed is intended to be a safer, more economical means of oxidizing organic carbon and determining the TOC levels of aqueous solutions and for providing a low power/mass unit for use in planetary missions.

  8. Utilization of the research reactors for the power reactor control instrumentation development

    International Nuclear Information System (INIS)

    Duchene, J.; Verdant, R.; Gilbert, J.

    1977-01-01

    Studies on characteristics and reliability of control instruments lead to testing with various radiations of various intensities and energy spectra. Osiris and Triton reactors present this great variety of radiations and a flexibility of use better than power reactors [fr

  9. Activities of research-reactor-technology project in FNCA from FY2005 to FY2007. Sharing neutronics calculation technique for core management and utilization of research reactors

    International Nuclear Information System (INIS)

    2010-07-01

    RRT project (Research-Reactor-Technology Project) was carried out with the theme of 'sharing neutronics calculation technique for core management and utilization of research reactors' in the framework of FNCA (Forum for Nuclear Cooperation in Asia) from FY2005 to FY2007. The objective of the project was to improve and equalize the level of neutronics calculation technique for the reactor core management among participating countries to assure the safe and stable operation of research reactors and the promotion of the effective utilization. Neutronics calculation codes, namely SRAC code system and MVP code, were adopted as common codes. Participating countries succeeded in applying the common codes to analyzing the core of each domestic research reactor. Some participating countries succeeded in applying the common codes to analyzing for utilization of own research reactors. Activities of RRT project have improved and equalized the level of neutronics calculation technique among participating countries. (author)

  10. In-Pile Instrumentation Multi- Parameter System Utilizing Photonic Fibers and Nanovision

    Energy Technology Data Exchange (ETDEWEB)

    Burgett, Eric [Idaho State Univ., Pocatello, ID (United States)

    2015-10-13

    An advanced in-pile multi-parameter reactor monitoring system is being proposed in this funding opportunity. The proposed effort brings cutting edge, high fidelity optical measurement systems into the reactor environment in an unprecedented fashion, including in-core, in-cladding and in-fuel pellet itself. Unlike instrumented leads, the proposed system provides a unique solution to a multi-parameter monitoring need in core while being minimally intrusive in the reactor core. Detector designs proposed herein can monitor fuel compression and expansion in both the radial and axial dimensions as well as monitor linear power profiles and fission rates during the operation of the reactor. In addition to pressure, stress, strain, compression, neutron flux, neutron spectra, and temperature can be observed inside the fuel bundle and fuel rod using the proposed system. The proposed research aims at developing radiation-hard, harsh-environment multi-parameter systems for insertion into the reactor environment. The proposed research holds the potential to drastically increase the fidelity and precision of in-core instrumentation with little or no impact in the neutron economy in the reactor environment while providing a measurement system capable of operation for entire operating cycles.

  11. In-Pile Instrumentation Multi- Parameter System Utilizing Photonic Fibers and Nanovision

    International Nuclear Information System (INIS)

    Burgett, Eric

    2015-01-01

    An advanced in-pile multi-parameter reactor monitoring system is being proposed in this funding opportunity. The proposed effort brings cutting edge, high fidelity optical measurement systems into the reactor environment in an unprecedented fashion, including in-core, in-cladding and in-fuel pellet itself. Unlike instrumented leads, the proposed system provides a unique solution to a multi-parameter monitoring need in core while being minimally intrusive in the reactor core. Detector designs proposed herein can monitor fuel compression and expansion in both the radial and axial dimensions as well as monitor linear power profiles and fission rates during the operation of the reactor. In addition to pressure, stress, strain, compression, neutron flux, neutron spectra, and temperature can be observed inside the fuel bundle and fuel rod using the proposed system. The proposed research aims at developing radiation-hard, harsh-environment multi-parameter systems for insertion into the reactor environment. The proposed research holds the potential to drastically increase the fidelity and precision of in-core instrumentation with little or no impact in the neutron economy in the reactor environment while providing a measurement system capable of operation for entire operating cycles.

  12. Electron Density Measurement on JUICE Mission by Mutual Impedance Technique: MIME Instrument as a Part of RPWI Consortium

    Science.gov (United States)

    Rauch, J. L.; Henri, P.; Wahlund, J. E.; Le Duff, O.; Sene, O.; Colin, F.; Lagoutte, D.; Gilet, N.; Ahlen, L.; Bergman, J.; Gill, R.; Puccio, W.

    2017-09-01

    Mutual Impedance MEasurements (MIME) instrument is a part of the Radio Wave Plasma Investigation (RPWI) consortium which has been selected by European Space Agency (ESA) on the nest planetary mission JJUpiter ICy moons Exploer (JUICE) for a launch in 2022. The goals are to explore Jupiter and its potentially habitable icy moons and to study its plasma environment. Impedance probes, which are well known in geophysical prospection, in particular for ground permittivity investigations, have been successfully transposed to space plasmas diagnostic. Transmitting and receiving electrodes are used for measuring on open circuit the dynamic impedance of the system at several fixed frequencies over a range that includes characteristic frequencies of the ambient plasma. The measurements are then interpreted using a suitable theory and the values of plasma parameters, such as the electron density and possibly the temperature of the plasma can be deduced. To show how powerful this technique is, results obtained in the Earth's plasmasphere by the mutual impedance probe onboard ROSETTA are presented as example. MIME instrument proposal is then described and its ability to make valuable measurements in the Jupiter space environment and in particular around Europe, Callisto and Ganymede is investigated..

  13. Utilization of advanced calibration techniques in stochastic rock fall analysis of quarry slopes

    Science.gov (United States)

    Preh, Alexander; Ahmadabadi, Morteza; Kolenprat, Bernd

    2016-04-01

    In order to study rock fall dynamics, a research project was conducted by the Vienna University of Technology and the Austrian Central Labour Inspectorate (Federal Ministry of Labour, Social Affairs and Consumer Protection). A part of this project included 277 full-scale drop tests at three different quarries in Austria and recording key parameters of the rock fall trajectories. The tests involved a total of 277 boulders ranging from 0.18 to 1.8 m in diameter and from 0.009 to 8.1 Mg in mass. The geology of these sites included strong rock belonging to igneous, metamorphic and volcanic types. In this paper the results of the tests are used for calibration and validation a new stochastic computer model. It is demonstrated that the error of the model (i.e. the difference between observed and simulated results) has a lognormal distribution. Selecting two parameters, advanced calibration techniques including Markov Chain Monte Carlo Technique, Maximum Likelihood and Root Mean Square Error (RMSE) are utilized to minimize the error. Validation of the model based on the cross validation technique reveals that in general, reasonable stochastic approximations of the rock fall trajectories are obtained in all dimensions, including runout, bounce heights and velocities. The approximations are compared to the measured data in terms of median, 95% and maximum values. The results of the comparisons indicate that approximate first-order predictions, using a single set of input parameters, are possible and can be used to aid practical hazard and risk assessment.

  14. Application of a model of instrumental conditioning to mobile robot control

    Science.gov (United States)

    Saksida, Lisa M.; Touretzky, D. S.

    1997-09-01

    Instrumental conditioning is a psychological process whereby an animal learns to associate its actions with their consequences. This type of learning is exploited in animal training techniques such as 'shaping by successive approximations,' which enables trainers to gradually adjust the animal's behavior by giving strategically timed reinforcements. While this is similar in principle to reinforcement learning, the real phenomenon includes many subtle effects not considered in the machine learning literature. In addition, a good deal of domain information is utilized by an animal learning a new task; it does not start from scratch every time it learns a new behavior. For these reasons, it is not surprising that mobile robot learning algorithms have yet to approach the sophistication and robustness of animal learning. A serious attempt to model instrumental learning could prove fruitful for improving machine learning techniques. In the present paper, we develop a computational theory of shaping at a level appropriate for controlling mobile robots. The theory is based on a series of mechanisms for 'behavior editing,' in which pre-existing behaviors, either innate or previously learned, can be dramatically changed in magnitude, shifted in direction, or otherwise manipulated so as to produce new behavioral routines. We have implemented our theory on Amelia, an RWI B21 mobile robot equipped with a gripper and color video camera. We provide results from training Amelia on several tasks, all of which were constructed as variations of one innate behavior, object-pursuit.

  15. Bioprinting of Cartilage and Skin Tissue Analogs Utilizing a Novel Passive Mixing Unit Technique for Bioink Precellularization

    Science.gov (United States)

    Thayer, Patrick Scott; Orrhult, Linnea Stridh; Martínez, Héctor

    2018-01-01

    Bioprinting is a powerful technique for the rapid and reproducible fabrication of constructs for tissue engineering applications. In this study, both cartilage and skin analogs were fabricated after bioink pre-cellularization utilizing a novel passive mixing unit technique. This technique was developed with the aim to simplify the steps involved in the mixing of a cell suspension into a highly viscous bioink. The resolution of filaments deposited through bioprinting necessitates the assurance of uniformity in cell distribution prior to printing to avoid the deposition of regions without cells or retention of large cell clumps that can clog the needle. We demonstrate the ability to rapidly blend a cell suspension with a bioink prior to bioprinting of both cartilage and skin analogs. Both tissue analogs could be cultured for up to 4 weeks. Histological analysis demonstrated both cell viability and deposition of tissue specific extracellular matrix (ECM) markers such as glycosaminoglycans (GAGs) and collagen I respectively. PMID:29364216

  16. Limit of detection in the presence of instrumental and non-instrumental errors: study of the possible sources of error and application to the analysis of 41 elements at trace levels by inductively coupled plasma-mass spectrometry technique

    International Nuclear Information System (INIS)

    Badocco, Denis; Lavagnini, Irma; Mondin, Andrea; Tapparo, Andrea; Pastore, Paolo

    2015-01-01

    In this paper the detection limit was estimated when signals were affected by two error contributions, namely instrumental errors and operational-non-instrumental errors. The detection limit was theoretically obtained following the hypothesis testing schema implemented with the calibration curve methodology. The experimental calibration design was based on J standards measured I times with non-instrumental errors affecting each standard systematically but randomly among the J levels. A two-component variance regression was performed to determine the calibration curve and to define the detection limit in these conditions. The detection limit values obtained from the calibration at trace levels of 41 elements by ICP-MS resulted larger than those obtainable from a one component variance regression. The role of the reagent impurities on the instrumental errors was ascertained and taken into account. Environmental pollution was studied as source of non-instrumental errors. The environmental pollution role was evaluated by Principal Component Analysis technique (PCA) applied to a series of nine calibrations performed in fourteen months. The influence of the seasonality of the environmental pollution on the detection limit was evidenced for many elements usually present in the urban air particulate. The obtained results clearly indicated the need of using the two-component variance regression approach for the calibration of all the elements usually present in the environment at significant concentration levels. - Highlights: • Limit of detection was obtained considering a two variance component regression. • Calibration data may be affected by instrumental and operational conditions errors. • Calibration model was applied to determine 41 elements at trace level by ICP-MS. • Non instrumental errors were evidenced by PCA analysis

  17. Instruments and techniques for analysing the time-resolved transverse phase space distribution of high-brightness electron beams

    International Nuclear Information System (INIS)

    Rudolph, Jeniffa

    2012-01-01

    This thesis deals with the instruments and techniques used to characterise the transverse phase space distribution of high-brightness electron beams. In particular, methods are considered allowing to measure the emittance as a function of the longitudinal coordinate within the bunch (slice emittance) with a resolution in the ps to sub-ps range. The main objective of this work is the analysis of techniques applicable for the time-resolved phase space characterisation for future high-brightness electron beam sources and single-pass accelerators based on these. The competence built up by understanding and comparing different techniques is to be used for the design and operation of slice diagnostic systems for the Berlin Energy Recovery Linac Project (BERLinPro). In the framework of the thesis, two methods applicable for slice emittance measurements are considered, namely the zero-phasing technique and the use of a transverse deflector. These methods combine the conventional quadrupole scan technique with a transfer of the longitudinal distribution into a transverse distribution. Measurements were performed within different collaborative projects. The experimental setup, the measurement itself and the data analysis are discussed as well as measurement results and simulations. In addition, the phase space tomography technique is introduced. In contrast to quadrupole scan-based techniques, tomography is model-independent and can reconstruct the phase space distribution from simple projected measurements. The developed image reconstruction routine based on the Maximum Entropy algorithm is introduced. The quality of the reconstruction is tested using different model distributions, simulated data and measurement data. The results of the tests are presented. The adequacy of the investigated techniques, the experimental procedures as well as the developed data analysis tools could be verified. The experimental and practical experience gathered during this work, the

  18. FY 1998 R and D of utilization of biological resources such as those in bioconsortia. Report on development results of techniques for utilization/production of organisms in bioconsortia; 1998 nendo fukugo seibutsukeinado seibutsu shigen riyo gijutsu kaihatsu seika hokokusho. Fukugo seibutsukei riyo seisan gijutsu no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    The objectives are set to analyze functions and interactions of organisms having specific functions, to develop the techniques for isolating and cultivating the constituent organisms, and thereby to develop the techniques for their industrial utilization, in order to develop the techniques for handling organisms in bioconsortia as the techniques to utilize their functions, e.g., production and decomposition of materials, and also to develop the techniques for culturing/controlling microorganisms in bioconsortia and for strengthening their functions. The FY 1998 themes are development of the functional material production technology, and comprehensive study for the project. More concretely, the former includes histochemical analytical technology (development of techniques for detecting microorganisms in soil, and of techniques for in-situ detection/isolation of specific microorganisms in bioconsortia and for analysis their functions), isolation and culture technology (development of detection, separation and cultivation technology of microorganisms that are not easily cultured), functional substance production technology (technical utilization of microbial consortia for production of environment-friendly oil/water separation polymers), and functional material production technology (development of methods for artificial gene exchange in microbial consortia). (NEDO)

  19. The Utility of Risk Assessment Instruments for the Prediction of Recidivism in Sexual Homicide Perpetrators

    Science.gov (United States)

    Hill, Andreas; Rettenberger, Martin; Habermann, Niels; Berner, Wolfgang; Eher, Reinhard; Briken, Peer

    2012-01-01

    To examine the predictive accuracy of four well established risk assessment instruments (PCL-R, HCR-20, SVR-20, and Static-99) in an important subgroup of sexual offenders, these instruments were assessed retrospectively based on information from forensic psychiatric court reports in a sample of 90 released male sexual homicide offenders (out of…

  20. Instrumentation requirements from the user's view

    International Nuclear Information System (INIS)

    Harsha, P.T.

    1988-01-01

    The use of combustor diagnostics is considered from the point of view of demonstration of performance of an airbreathing hypersonic engine. The basic need is seen to be that of providing the data necessary to verify performance predictions for the engine as installed in the airplane. This necessitates the use of a diagnostics capability that can provide the inputs required by the computational analyses that will be used to assess this performance. Because of the cost of ground test facilities, a premium is placed on measurement technique reliability and redundancy of instrumentation. A mix of nonintrusive optical techniques and probe-based measurements is seen to be the best approach using current diagnostics capability; one such instrument mix is outlined for a ramjet/scramjet test program. 11 references

  1. Cost-Utility Analysis of Pedicle Screw Removal After Successful Posterior Instrumented Fusion in Thoracolumbar Burst Fractures.

    Science.gov (United States)

    Lee, Han-Dong; Jeon, Chang-Hoon; Chung, Nam-Su; Seo, Young-Wook

    2017-08-01

    A cost-utility analysis (CUA). The aim of this study was to determine the cost-effectiveness of pedicle screw removal after posterior fusion in thoracolumbar burst fractures. Pedicle screw instrumentation is a standard fixation method for unstable thoracolumbar burst fracture. However, removal of the pedicle screw after successful fusion remains controversial because the clinical benefits remain unclear. CUA can help clinicians make appropriate decisions about optimal health care for pedicle screw removal after successful fusion in thoracolumbar burst fractures. We conducted a single-center, retrospective, longitudinal matched-cohort study of prospectively collected outcomes. In total, 88 consecutive patients who had undergone pedicle screw instrumentation for thoracolumbar burst fracture with successful fusion confirmed by computed tomography (CT) were used in this study. In total, 45 patients wanted to undergo implant removal surgery (R group), and 43 decided not to remove the implant (NR group). A CUA was conducted from the health care perspective. The direct costs of health care were obtained from the medical bill of each patient. Changes in health-related quality of life (HRQoL) scores, validated by Short Form 6D, were used to calculate quality-adjusted life-years (QALYs). Total costs and gained QALY were calculated at 1 year (1 year) and 2 years (2 years) compared with baseline. Results are expressed as an incremental cost-effectiveness ratio (ICER). Different discount rates (0%, 3%, and 5%) were applied to both cost and QALY for sensitivity analysis. Baseline patient variables were similar between the two groups (all P > 0.05). The additional benefits of implant removal (0.201 QALY at 2 years) were achieved with additional costs ($2541 at 2 years), equating to an ICER of $12,641/QALY. On the basis of the different discount rates, the robustness of our study's results was also determined. Implant removal after successful fusion in a thoracolumbar burst

  2. A differential absorption technique to estimate atmospheric total water vapor amounts

    Science.gov (United States)

    Frouin, Robert; Middleton, Elizabeth

    1990-01-01

    Vertically integrated water-vapor amounts can be remotely determined by measuring the solar radiance reflected by the earth's surface with satellites or aircraft-based instruments. The technique is based on the method by Fowle (1912, 1913) and utilizes the 0.940-micron water-vapor band to retrieve total-water-vapor data that is independent of surface reflectance properties and other atmospheric constituents. A channel combination is proposed to provide more accurate results, the SE-590 spectrometer is used to verify the data, and the effects of atmospheric photon backscattering is examined. The spectrometer and radiosonde data confirm the accuracy of using a narrow and a wide channel centered on the same wavelength to determine water vapor amounts. The technique is suitable for cloudless conditions and can contribute to atmospheric corrections of land-surface parameters.

  3. Radiation measuring instrument

    International Nuclear Information System (INIS)

    Genrich, V.

    1985-01-01

    A highly sensitive and compactly structured radiation measuring instrument for detecting ionizing radiation, in particular for measuring dose rates and contamination. The laminar structure of the associated counter tube, using only a few, simple plastic parts and a highly elastic counter wire, makes it possible to use the simplest manufacturing techniques. The service life of the counter tube construction, which is completely and permanently sealed and filled with gas, is expected to be more than 12 years. The described counter tube can be adapted in optimal fashion to the available space in a pocket instrument if it is used in combination with a specialized high-voltage generator which is low in interference voltage and with a pulse evaluation circuit having a means of compensating for interference voltage

  4. Comparison of three aerosol chemical characterization techniques utilizing PTR-ToF-MS: a study on freshly formed and aged biogenic SOA

    Directory of Open Access Journals (Sweden)

    G. I. Gkatzelis

    2018-03-01

    Full Text Available An intercomparison of different aerosol chemical characterization techniques has been performed as part of a chamber study of biogenic secondary organic aerosol (BSOA formation and aging at the atmosphere simulation chamber SAPHIR (Simulation of Atmospheric PHotochemistry In a large Reaction chamber. Three different aerosol sampling techniques – the aerosol collection module (ACM, the chemical analysis of aerosol online (CHARON and the collection thermal-desorption unit (TD were connected to proton transfer reaction time-of-flight mass spectrometers (PTR-ToF-MSs to provide chemical characterization of the SOA. The techniques were compared among each other and to results from an aerosol mass spectrometer (AMS and a scanning mobility particle sizer (SMPS. The experiments investigated SOA formation from the ozonolysis of β-pinene, limonene, a β-pinene–limonene mix and real plant emissions from Pinus sylvestris L. (Scots pine. The SOA was subsequently aged by photo-oxidation, except for limonene SOA, which was aged by NO3 oxidation. Despite significant differences in the aerosol collection and desorption methods of the PTR-based techniques, the determined chemical composition, i.e. the same major contributing signals, was found by all instruments for the different chemical systems studied. These signals could be attributed to known products expected from the oxidation of the examined monoterpenes. The sampling and desorption method of ACM and TD provided additional information on the volatility of individual compounds and showed relatively good agreement. Averaged over all experiments, the total aerosol mass recovery compared to an SMPS varied within 80 ± 10, 51 ± 5 and 27 ± 3 % for CHARON, ACM and TD, respectively. Comparison to the oxygen-to-carbon ratios (O : C obtained by AMS showed that all PTR-based techniques observed lower O : C ratios, indicating a loss of molecular oxygen either during aerosol sampling or

  5. Automatic classification of minimally invasive instruments based on endoscopic image sequences

    Science.gov (United States)

    Speidel, Stefanie; Benzko, Julia; Krappe, Sebastian; Sudra, Gunther; Azad, Pedram; Müller-Stich, Beat Peter; Gutt, Carsten; Dillmann, Rüdiger

    2009-02-01

    Minimally invasive surgery is nowadays a frequently applied technique and can be regarded as a major breakthrough in surgery. The surgeon has to adopt special operation-techniques and deal with difficulties like the complex hand-eye coordination and restricted mobility. To alleviate these constraints we propose to enhance the surgeon's capabilities by providing a context-aware assistance using augmented reality techniques. To analyze the current situation for context-aware assistance, we need intraoperatively gained sensor data and a model of the intervention. A situation consists of information about the performed activity, the used instruments, the surgical objects, the anatomical structures and defines the state of an intervention for a given moment in time. The endoscopic images provide a rich source of information which can be used for an image-based analysis. Different visual cues are observed in order to perform an image-based analysis with the objective to gain as much information as possible about the current situation. An important visual cue is the automatic recognition of the instruments which appear in the scene. In this paper we present the classification of minimally invasive instruments using the endoscopic images. The instruments are not modified by markers. The system segments the instruments in the current image and recognizes the instrument type based on three-dimensional instrument models.

  6. Assessment of wind turbine load measurement instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Morfiadakis, E; Papadopoulos, K [CRES (Greece); Borg, N van der [ECN, Petten (Netherlands); Petersen, S M [Risoe, Roskilde (Denmark); Seifert, H [DEWI, Wilhelmshaven (Germany)

    1999-03-01

    In the framework of Sub-Task3 `Wind turbine load measurement instrumentation` of EU-project `European Wind Turbine Testing Procedure Development`, the load measurement techniques have been assessed by laboratory, full scale and numerical tests. The existing methods have been reviewed with emphasis on the strain gage application techniques on composite materials and recommendations are provided for the optimisation of load measurement techniques. (au) EU. 14 refs.

  7. Power-assisted liposuction and the pull-through technique for the treatment of gynecomastia.

    Science.gov (United States)

    Lista, Frank; Ahmad, Jamil

    2008-03-01

    Gynecomastia is a common condition affecting many adolescent and adult males. Surgical techniques utilizing a variety of incisions, excisions, suction-assisted lipectomy, ultrasound-assisted liposuction, power-assisted liposuction, or some combination of these methods have been used in the treatment of gynecomastia. This article describes the authors' method of using power-assisted liposuction and the pull-through technique to treat gynecomastia. This technique involves the use of power-assisted liposuction to remove fatty breast tissue. The pull-through technique is then performed utilizing several instruments to sever the subdermal attachments of fibroglandular breast tissue; this tissue is removed through the incision used for liposuction. Finally, power-assisted liposuction is performed again to contour the remaining breast tissue. A chart review of 99 consecutive patients (197 breasts) treated between January of 2003 and November of 2006 was performed. Ninety-six patients (192 breasts) were successfully treated using this technique. Power-assisted liposuction was performed in all cases, and the average volume aspirated per breast was 459 ml (range, 25 to 1400 ml). Using the pull-through technique, the authors were able to remove between 5 and 70 g of tissue per breast. Complications were minimal (1.0 percent of breasts), and no revisions were required. Since January of 2003, the authors have used this technique to successfully treat 97 percent of their gynecomastia patients. Combining power-assisted liposuction and the pull-through technique has proven to be a versatile approach for the treatment of gynecomastia and consistently produces a naturally contoured male breast while resulting in a single inconspicuous scar.

  8. Instrumentation Cables Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Muna, Alice Baca [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); LaFleur, Chris Bensdotter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-10-01

    A fire at a nuclear power plant (NPP) has the potential to damage structures, systems, and components important to safety, if not promptly detected and suppressed. At Browns Ferry Nuclear Power Plant on March 22, 1975, a fire in the reactor building damaged electrical power and control systems. Damage to instrumentation cables impeded the function of both normal and standby reactor coolant systems, and degraded the operators’ plant monitoring capability. This event resulted in additional NRC involvement with utilities to ensure that NPPs are properly protected from fire as intended by the NRC principle design criteria (i.e., general design criteria 3, Fire Protection). Current guidance and methods for both deterministic and performance based approaches typically make conservative (bounding) assumptions regarding the fire-induced failure modes of instrumentation cables and those failure modes effects on component and system response. Numerous fire testing programs have been conducted in the past to evaluate the failure modes and effects of electrical cables exposed to severe thermal conditions. However, that testing has primarily focused on control circuits with only a limited number of tests performed on instrumentation circuits. In 2001, the Nuclear Energy Institute (NEI) and the Electric Power Research Institute (EPRI) conducted a series of cable fire tests designed to address specific aspects of the cable failure and circuit fault issues of concern1. The NRC was invited to observe and participate in that program. The NRC sponsored Sandia National Laboratories to support this participation, whom among other things, added a 4-20 mA instrumentation circuit and instrumentation cabling to six of the tests. Although limited, one insight drawn from those instrumentation circuits tests was that the failure characteristics appeared to depend on the cable insulation material. The results showed that for thermoset insulated cables, the instrument reading tended to drift

  9. A low tritium hydride bed inventory estimation technique

    Energy Technology Data Exchange (ETDEWEB)

    Klein, J.E.; Shanahan, K.L.; Baker, R.A. [Savannah River National Laboratory, Aiken, SC (United States); Foster, P.J. [Savannah River Nuclear Solutions, Aiken, SC (United States)

    2015-03-15

    Low tritium hydride beds were developed and deployed into tritium service in Savannah River Site. Process beds to be used for low concentration tritium gas were not fitted with instrumentation to perform the steady-state, flowing gas calorimetric inventory measurement method. Low tritium beds contain less than the detection limit of the IBA (In-Bed Accountability) technique used for tritium inventory. This paper describes two techniques for estimating tritium content and uncertainty for low tritium content beds to be used in the facility's physical inventory (PI). PI are performed periodically to assess the quantity of nuclear material used in a facility. The first approach (Mid-point approximation method - MPA) assumes the bed is half-full and uses a gas composition measurement to estimate the tritium inventory and uncertainty. The second approach utilizes the bed's hydride material pressure-composition-temperature (PCT) properties and a gas composition measurement to reduce the uncertainty in the calculated bed inventory.

  10. Clinical Evaluation of Quality of Obturation and Instrumentation Time using Two Modified Rotary File Systems with Manual Instrumentation in Primary Teeth.

    Science.gov (United States)

    Govindaraju, Lavanya; Jeevanandan, Ganesh; Subramanian, Emg

    2017-09-01

    Pulp therapy in primary teeth has been performed using various instrumentation techniques. However, the conventional instrumentation technique used for root canal preparation in primary teeth is hand instrumentation. Various Nickel-Titanium (Ni-Ti) instruments are available to perform efficient root canal preparation in primary teeth. These Ni-Ti instruments has been designed to aid in better root canal preparation in permanent teeth but are rarely used in primary teeth. It is necessary to assess the feasibility of using these adult rotary files with a modified sequence in primary teeth. To compare the quality of obturation and instrumentation time during root canal preparation using hand files and modified rotary file systems in primary molars. Forty-five primary mandibular molars were randomly assigned to three experimental groups (n=15). Group I was instrumented using k-hand files, Group II with S2 ProTaper universal file and Group III with 0.25 tip 4% taper K3 rotary file. Standardized digital radiographs were taken before and after root canal instrumentation. Root canal preparation time was also recorded. Statistical analysis of the obtained data was done using SPSS Software version 17.0. An intergroup comparison of the instrumentation time and the quality of obturation was done using ANOVA and Chi-square test with the level of significance set at 0.05. No significant differences were noted with regard to the quality of obturation (p=0.791). However, a statistically significant difference was noted in the instrumentation time between the three groups (pProTaper rotary system had significantly lesser instrumentation time when compared to that of K3 rotary system and hand file system. The hand files, S2 ProTaper Universal and K3 0.25 tip 4% taper files systems performed similarly with respect to the quality of obturation. There was a significant difference in instrumentation time with manual instrumentation compared to the modified rotary file systems in primary

  11. Advanced Instrumentation and Measurement Techniques for Near Surface Flows

    Science.gov (United States)

    Cadel, Daniel R.

    The development of aerodynamic boundary layers on wind turbine blades is an important consideration in their performance. It can be quite challenging to replicate full scale conditions in laboratory experiments, and advanced diagnostics become valuable in providing data not available from traditional means. A new variant of Doppler global velocimetry (DGV) known as cross-correlation DGV is developed to measure boundary layer profiles on a wind turbine blade airfoil in the large scale Virginia Tech Stability Wind Tunnel. The instrument provides mean velocity vectors with reduced sensitivity to external conditions, a velocity measurement range from 0 ms-1 to over 3000 ms-1, and an absolute uncertainty. Monte Carlo simulations with synthetic signals reveal that the processing routine approaches the Cramer-Rao lower bound in optimized conditions. A custom probe-beam technique is implanted to eliminate laser flare for measuring boundary layer profiles on a DU96-W-180 wind turbine airfoil model. Agreement is seen with laser Doppler velocimetry data within the uncertainty estimated for the DGV profile. Lessons learned from the near-wall flow diagnostics development were applied to a novel benchmark model problem incorporating the relevant physical mechanisms of the high amplitude periodic turbulent flow experienced by turbine blades in the field. The model problem is developed for experimentally motivated computational model development. A circular cylinder generates a periodic turbulent wake, in which a NACA 63215b airfoil with a chord Reynolds number Rec = 170,000 is embedded for a reduced frequency k = pi f c/V = 1.53. Measurements are performed with particle image velocimetry on the airfoil suction side and in highly magnified planes within the boundary layer. Outside of the viscous region, the Reynolds stress profile is consistent with the prediction of Rapid Distortion Theory (RDT), confirming that the redistribution of normal stresses is an inviscid effect. The

  12. Contemporary management of carotid blowout syndrome utilizing endovascular techniques.

    Science.gov (United States)

    Manzoor, Nauman F; Rezaee, Rod P; Ray, Abhishek; Wick, Cameron C; Blackham, Kristine; Stepnick, David; Lavertu, Pierre; Zender, Chad A

    2017-02-01

    To illustrate complex interdisciplinary decision making and the utility of modern endovascular techniques in the management of patients with carotid blowout syndrome (CBS). Retrospective chart review. Patients treated with endovascular strategies and/or surgical modalities were included. Control of hemorrhage, neurological, and survival outcomes were studied. Between 2004 and 2014, 33 patients had 38 hemorrhagic events related to head and neck cancer that were managed with endovascular means. Of these, 23 were localized to the external carotid artery (ECA) branches and five localized to the ECA main trunk; nine were related to the common carotid artery (CCA) or internal carotid artery (ICA), and one event was related to the innominate artery. Seven events related to the CCA/ICA or innominate artery were managed with endovascular sacrifice, whereas three cases were managed with a flow-preserving approach (covered stent). Only one patient developed permanent hemiparesis. In two of the three cases where the flow-preserving approach was used, the covered stent eventually became exposed via the overlying soft tissue defect, and definitive management using carotid revascularization or resection was employed to prevent further hemorrhage. In cases of soft tissue necrosis, vascularized tissues were used to cover the great vessels as applicable. The use of modern endovascular approaches for management of acute CBS yields optimal results and should be employed in a coordinated manner by the head and neck surgeon and the neurointerventionalist. 4. Laryngoscope, 2016 127:383-390, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  13. New type of radiation instrumentation system

    International Nuclear Information System (INIS)

    Matsuo, Keichi; Takaoka, Akira; Uranaka, Yasuo

    2000-01-01

    The Mitsubishi Electric Co., Ltd. developed a radiation instrumentation system introduced some recent techniques such as computation technique, network technique and so on into conventional radiation detection aiming at general market except power generation company. In a conventional system, a detector and an operation processing board was placed at a field and center, respectively, and a feeble pulse signal from the detector was transferred to the operation processing board. Then, on establishment of cables, detectors and operation processing board, it is essential to carry out engineering planning and field engineering conceiving on noise countermeasure. Noise resistance of the new type of radiation instrumentation system, not by adding operation processing function and network interface function into a detector unit in a field to transfer feeble signal, but by transferring testing result as a digital signal. And, noise removing function capable of selectively passing only signal pulse waveform from the detector to judge its signal waveform was also added to a detector unit in the field, to carry out a thoroughly removing noise. In addition, by connecting between each apparatus placed at the field with a network a system capable of reducing some cable engineering could be executed. Here were introduced on abstract of this new type of radiation instrumentation system and on noise removing function of its characteristics. (G.K.)

  14. Optimizing Availability of a Framework in Series Configuration Utilizing Markov Model and Monte Carlo Simulation Techniques

    Directory of Open Access Journals (Sweden)

    Mansoor Ahmed Siddiqui

    2017-06-01

    Full Text Available This research work is aimed at optimizing the availability of a framework comprising of two units linked together in series configuration utilizing Markov Model and Monte Carlo (MC Simulation techniques. In this article, effort has been made to develop a maintenance model that incorporates three distinct states for each unit, while taking into account their different levels of deterioration. Calculations are carried out using the proposed model for two distinct cases of corrective repair, namely perfect and imperfect repairs, with as well as without opportunistic maintenance. Initially, results are accomplished using an analytical technique i.e., Markov Model. Validation of the results achieved is later carried out with the help of MC Simulation. In addition, MC Simulation based codes also work well for the frameworks that follow non-exponential failure and repair rates, and thus overcome the limitations offered by the Markov Model.

  15. 浅谈提高大型仪器设备使用效率的措施%Discussion on improving utilization efficiency of large instruments and equipment

    Institute of Scientific and Technical Information of China (English)

    吴冰; 张勇

    2011-01-01

    大型仪器设备在高校学科建设中起着重要的支撑作用,高校对仪器设备的投人逐年增加,本文从提高机时利用率、管理人员素质和健全管理制度等方面探讨了提高大型仪器设备使用效率的措施.%Large instruments and equipment play an important supporting role in the building of academic disciplines in colleges and universities, and funds apropriated for their purchase and operation are increasing each year. This paper discusses the methods to improve the utilization efficiency of these instruments through improving the quality of management staff and administration system and increasing the usage factor.

  16. Study of the uniform corrosion of non alloy and stainless steels: combined utilization of acoustic emission and electrochemical techniques

    International Nuclear Information System (INIS)

    Jaubert, Lionel

    2004-01-01

    In chemical and petrochemical industry, uniform corrosion induces important economic and security disappointments. The mechanisms of this damaging corrosion mode are well understood, but methods for on-line detection are badly missing. Acoustic emission technique presents, to palliate this lack, potentialities that have been studied in an instrumented laboratory loop allowing the simulation of industrial uniform corrosion conditions. In acidic media, acoustic activity is related to the hydrogen evolution resulting from proton reduction; it is therefore well correlated to the damage severity. In neutral aerated media, the deposit formation of corrosion products is not very emissive. Yet, a specific study of frequency parameters allows detection of corrosion evolution, but in that case, the quantification of corrosion rate remains difficult. A subsidiary study confirms the technique applicability in the case of 'acidic' corrosion, even in very noisy conditions. (author) [fr

  17. A Report on The Data Acquisition and On-line Instrument Technique Development for FTL

    International Nuclear Information System (INIS)

    Sim, B. S.; Chi, D. Y.; Lee, C. Y.; Park, S. K.; Lee, J. M.; Ahn, S. H.; Kim, Y. K.

    2009-01-01

    Documents produced during the design, procurement manufacturing, and commissioning stage for the instruments such as SPND, Thermocouple, and LVDT which are installed on the In-pile section(IPS) of the fuel test loop(FTL) are gathered together. The values measured by the instruments are stored on the database of the data acquisition system(DAS) and displayed through both DAS and remote monitoring system installed on the users office. The commissioning status and the problems and items to be improved which are revealed during the commissioning stage are described. The report will be used for the development and operation of the instruments in the near future

  18. Onboard calibration and monitoring for the SWIFT instrument

    International Nuclear Information System (INIS)

    Rahnama, P; McDade, I; Shepherd, G; Gault, W

    2012-01-01

    The SWIFT (Stratospheric Wind Interferometer for Transport studies) instrument is a proposed space-based field-widened Doppler Michelson interferometer designed to measure stratospheric winds and ozone densities using a passive optical technique called Doppler Michelson imaging interferometry. The onboard calibration and monitoring procedures for the SWIFT instrument are described in this paper. Sample results of the simulations of onboard calibration measurements are presented and discussed. This paper also discusses the results of the derivation of the calibrations and monitoring requirements for the SWIFT instrument. SWIFT's measurement technique and viewing geometry are briefly described. The reference phase calibration and filter monitoring for the SWIFT instrument are two of the main critical design issues. In this paper it is shown that in order to meet SWIFT's science requirements, Michelson interferometer optical path difference monitoring corresponding to a phase calibration accuracy of ∼10 −3 radians, filter passband monitoring corresponding to phase accuracy of ∼5 × 10 −3 radians and a thermal stability of 10 −3 K s −1 are required. (paper)

  19. Inelastic scattering using the three-axis spectrometer technique

    International Nuclear Information System (INIS)

    Currat, R.

    1999-01-01

    The three-axis technique is a basic neutron scattering technique for inelastic work on single-crystal specimens. There is, at the moment, a fair degree of complementarity between TAS instruments on steady-state sources and TOF instruments on steady-state or pulsed sources. The technique is described, the issue of TAS versus TOF method is discussed, and investigations relating to the resolution functions are presented. (K.A.)

  20. Quantitative assessment of apical debris extrusion and intracanal debris in the apical third, using hand instrumentation and three rotary instrumentation systems.

    Science.gov (United States)

    H K, Sowmya; T S, Subhash; Goel, Beena Rani; T N, Nandini; Bhandi, Shilpa H

    2014-02-01

    Decreased apical extrusion of debris and apical one third debris have strong implications for decreased incidence of postoperative inflammation and pain. Thus, the aim of this study was to assess quantitatively the apical extrusion of debris and intracanal debris in the apical third during root canal instrumentation using hand and three different types of rotary instruments. Sixty freshly extracted single rooted human teeth were randomly divided into four groups. Canal preparation was done using step-back with hand instrumentation, crown-down technique with respect to ProTaper and K3, and hybrid technique with LightSpeed LSX. Irrigation was done with NaOCl, EDTA, and normal saline and for final irrigation, EndoVac system was used. The apically extruded debris was collected on the pre-weighed Millipore plastic filter disk and weighed using microbalance. The teeth were submitted to the histological processing. Sections from the apical third were analyzed by a trinocular research microscope that was coupled to a computer where the images were captured and analyzed using image proplus V4.1.0.0 software. The mean weight of extruded debris for each group and intracanal debris in the root canal was statistically analyzed by a Kruskal-Wallis one-way analysis of variance and Mann-Whitney U test. The result showed that, hand instrumentation using K files showed the highest amount of debris extrusion apically when compared to ProTaper, K3 and LightSpeed LSX. The result also showed that there was no statistically significant difference between the groups in relation to presence of intracanal debris in the apical one third. Based on the results, all instrumentation techniques produced debris extrusion. The engine driven Ni-Ti systems extruded significantly less apical debris than hand instrumentation. There was no statistically significant difference between the groups in relation to presence of intracanal debris in the apical one third.

  1. Assessment of Work Performance (AWP)--development of an instrument.

    Science.gov (United States)

    Sandqvist, Jan L; Törnquist, Kristina B; Henriksson, Chris M

    2006-01-01

    Adequate work assessments are a matter of importance both for individuals and society [5,29,31,38,40,46,52]. However, there is a lack of adequate and reliable instruments for use in work rehabilitation [14,15,20,21,31,44]. The purpose of this study was to develop and evaluate an observation instrument for assessing work performance, the AWP (Assessment of Work Performance). The purpose of the 14-item instrument is to assess the individual's observable working skills in three different areas: motor skills, process skills, and communication and interaction skills. This article describes the development and results of preliminary testing of the AWP. The testing indicates a satisfactory face validity and utility for the AWP and supports further research and testing of the instrument.

  2. A Comparison of Two Instruments for the Assessment of Legibility of ...

    African Journals Online (AJOL)

    Purpose: To compare the utility of a rating and visual analogue scale for the assessment of legibility in prescriptions Methods: A sample of fifty randomly selected ... Conclusion: The findings support the utility of both instruments in the assessment of handwriting but suggest that there may be important differences between ...

  3. The influence of parental concern on the utility of autism diagnostic instruments.

    Science.gov (United States)

    Havdahl, Karoline Alexandra; Bishop, Somer L; Surén, Pål; Øyen, Anne-Siri; Lord, Catherine; Pickles, Andrew; von Tetzchner, Stephen; Schjølberg, Synnve; Gunnes, Nina; Hornig, Mady; Lipkin, W Ian; Susser, Ezra; Bresnahan, Michaeline; Magnus, Per; Stenberg, Nina; Reichborn-Kjennerud, Ted; Stoltenberg, Camilla

    2017-10-01

    The parental report-based Autism Diagnostic Interview-Revised (ADI-R) and the clinician observation-based Autism Diagnostic Observation Schedule (ADOS) have been validated primarily in U.S. clinics specialized in autism spectrum disorder (ASD), in which most children are referred by their parents because of ASD concern. This study assessed diagnostic agreement of the ADOS-2 and ADI-R toddler algorithms in a more broadly based sample of 679 toddlers (age 35-47 months) from the Norwegian Mother and Child Cohort. We also examined whether parental concern about ASD influenced instrument performance, comparing toddlers identified based on parental ASD concern (n = 48) and parent-reported signs of developmental problems (screening) without a specific concern about ASD (n = 400). The ADOS cutoffs showed consistently well-balanced sensitivity and specificity. The ADI-R cutoffs demonstrated good specificity, but reduced sensitivity, missing 43% of toddlers whose parents were not specifically concerned about ASD. The ADI-R and ADOS dimensional scores agreed well with clinical diagnoses (area under the curve ≥ 0.85), contributing additively to their prediction. On the ADI-R, different cutoffs were needed according to presence or absence of parental ASD concern, in order to achieve comparable balance of sensitivity and specificity. These results highlight the importance of taking parental concern about ASD into account when interpreting scores from parental report-based instruments such as the ADI-R. While the ADOS cutoffs performed consistently well, the additive contributions of ADI-R and ADOS scores to the prediction of ASD diagnosis underscore the value of combining instruments based on parent accounts and clinician observation in evaluation of ASD. Autism Res 2017, 10: 1672-1686. © 2017 International Society for Autism Research, Wiley Periodicals, Inc. © 2017 International Society for Autism Research, Wiley Periodicals, Inc.

  4. Safeguards instrumentation: past, present, future

    International Nuclear Information System (INIS)

    Higinbotham, W.A.

    1982-01-01

    Instruments are essential for accounting, for surveillance and for protection of nuclear materials. The development and application of such instrumentation is reviewed, with special attention to international safeguards applications. Active and passive nondestructive assay techniques are some 25 years of age. The important advances have been in learning how to use them effectively for specific applications, accompanied by major advances in radiation detectors, electronics, and, more recently, in mini-computers. The progress in seals has been disappointingly slow. Surveillance cameras have been widely used for many applications other than safeguards. The revolution in TV technology will have important implications. More sophisticated containment/surveillance equipment is being developed but has yet to be exploited. On the basis of this history, some expectations for instrumentation in the near future are presented

  5. "Fibromyalgia and quality of life: mapping the revised fibromyalgia impact questionnaire to the preference-based instruments".

    Science.gov (United States)

    Collado-Mateo, Daniel; Chen, Gang; Garcia-Gordillo, Miguel A; Iezzi, Angelo; Adsuar, José C; Olivares, Pedro R; Gusi, Narcis

    2017-05-30

    The revised version of the Fibromyalgia Impact Questionnaire (FIQR) is one of the most widely used specific questionnaires in FM studies. However, this questionnaire does not allow calculation of QALYs as it is not a preference-based measure. The aim of this study was to develop mapping algorithm which enable FIQR scores to be transformed into utility scores that can be used in the cost utility analyses. A cross-sectional survey was conducted. One hundred and 92 Spanish women with Fibromyalgia were asked to complete four general quality of life questionnaires, i.e. EQ-5D-5 L, 15D, AQoL-8D and SF-12, and one specific disease instrument, the FIQR. A direct mapping approach was adopted to derive mapping algorithms between the FIQR and each of the four multi-attribute utility (MAU) instruments. Health state utility was treated as the dependent variable in the regression analysis, whilst the FIQR score and age were predictors. The mean utility scores ranged from 0.47 (AQoL-8D) to 0.69 (15D). All correlations between the FIQR total score and MAU instruments utility scores were highly significant (p fibromyalgia specific questionnaire.

  6. Neutrons and music: Imaging investigation of ancient wind musical instruments

    Science.gov (United States)

    Festa, G.; Tardino, G.; Pontecorvo, L.; Mannes, D. C.; Senesi, R.; Gorini, G.; Andreani, C.

    2014-10-01

    A set of seven musical instruments and two instruments cares from the 'Fondo Antico della Biblioteca del Sacro Convento' in Assisi, Italy, were investigated through neutron and X-ray imaging techniques. Historical and scientific interests around ancient musical instruments motivate an intense research effort for their characterization using non-destructive and non-invasive techniques. X-ray and neutron tomography/radiography were applied to the study of composite material samples containing wood, hide and metals. The study was carried out at the NEUTRA beamline, PSI (Paul Scherrer Institute, Switzerland). Results of the measurements provided new information on the composite and multi-scale structure, such as: the internal structure of the samples, position of added materials like metals, wood fiber displays, deformations, presence of adhesives and their spatial distribution and novel insight about construction methods to guide the instruments' restoration process.

  7. Evolutionary programming for neutron instrument optimisation

    Energy Technology Data Exchange (ETDEWEB)

    Bentley, Phillip M. [Hahn-Meitner Institut, Glienicker Strasse 100, D-14109 Berlin (Germany)]. E-mail: phillip.bentley@hmi.de; Pappas, Catherine [Hahn-Meitner Institut, Glienicker Strasse 100, D-14109 Berlin (Germany); Habicht, Klaus [Hahn-Meitner Institut, Glienicker Strasse 100, D-14109 Berlin (Germany); Lelievre-Berna, Eddy [Institut Laue-Langevin, 6 rue Jules Horowitz, BP 156, 38042 Grenoble Cedex 9 (France)

    2006-11-15

    Virtual instruments based on Monte-Carlo techniques are now integral part of novel instrumentation development and the existing codes (McSTAS and Vitess) are extensively used to define and optimise novel instrumental concepts. Neutron spectrometers, however, involve a large number of parameters and their optimisation is often a complex and tedious procedure. Artificial intelligence algorithms are proving increasingly useful in such situations. Here, we present an automatic, reliable and scalable numerical optimisation concept based on the canonical genetic algorithm (GA). The algorithm was used to optimise the 3D magnetic field profile of the NSE spectrometer SPAN, at the HMI. We discuss the potential of the GA which combined with the existing Monte-Carlo codes (Vitess, McSTAS, etc.) leads to a very powerful tool for automated global optimisation of a general neutron scattering instrument, avoiding local optimum configurations.

  8. Evolutionary programming for neutron instrument optimisation

    International Nuclear Information System (INIS)

    Bentley, Phillip M.; Pappas, Catherine; Habicht, Klaus; Lelievre-Berna, Eddy

    2006-01-01

    Virtual instruments based on Monte-Carlo techniques are now integral part of novel instrumentation development and the existing codes (McSTAS and Vitess) are extensively used to define and optimise novel instrumental concepts. Neutron spectrometers, however, involve a large number of parameters and their optimisation is often a complex and tedious procedure. Artificial intelligence algorithms are proving increasingly useful in such situations. Here, we present an automatic, reliable and scalable numerical optimisation concept based on the canonical genetic algorithm (GA). The algorithm was used to optimise the 3D magnetic field profile of the NSE spectrometer SPAN, at the HMI. We discuss the potential of the GA which combined with the existing Monte-Carlo codes (Vitess, McSTAS, etc.) leads to a very powerful tool for automated global optimisation of a general neutron scattering instrument, avoiding local optimum configurations

  9. Instrumentation and test gear circuits manual

    CERN Document Server

    Marston, R M

    2013-01-01

    Instrumentation and Test Gear Circuits Manual provides diagrams, graphs, tables, and discussions of several types of practical circuits. The practical circuits covered in this book include attenuators, bridges, scope trace doublers, timebases, and digital frequency meters. Chapter 1 discusses the basic instrumentation and test gear principles. Chapter 2 deals with the design of passive attenuators, and Chapter 3 with passive and active filter circuits. The subsequent chapters tackle 'bridge' circuits, analogue and digital metering techniques and circuitry, signal and waveform generation, and p

  10. Electron beam instrumentation techniques using coherent radiation

    International Nuclear Information System (INIS)

    Wang, D.X.

    1997-01-01

    Much progress has been made on coherent radiation research since coherent synchrotron radiation was first observed in 1989. The use of coherent radiation as a bunch length diagnostic tool has been studied by several groups. In this paper, brief introductions to coherent radiation and far-infrared measurement are given, the progress and status of their beam diagnostic application are reviewed, different techniques are described, and their advantages and limitations are discussed

  11. Report on evaluation of research and development of light-aided instrumentation/control systems. Abstract; Hikari oyo keisoku seigyo system no kenkyu kaihatsu ni kansuru hyoka hokokusho. Gaiyohen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1986-08-01

    This research and development project is aimed at commercialization of the light-aided instrumentation technology systems which safely, stably measure, transmit and control process information including image information, e.g., temperature, flow rates and components at large plants in industrial complexes, in the severe atmospheres in the presence of, e.g., electromagnetic induction and combustible gases. These optical systems need development of light transmitting/receiving devices, various optical devices that constitute the network nodes, and various types of sensors of improved functions and reliability, in addition to development of the techniques required for transmitting large quantities of information on a large scale. This project has attempted to systematically make break-through in the individual elementary techniques, in particular those in the widely diversified technological areas for the advanced devices, and thereby to expand the instrumentation/control technology frontiers. The results of studies on gallium/arsenic crystals, which are prerequisite for photoelectronic integrated circuits as the bases for the light application technology, and processes for producing thereof are highly rated worldwide. It is planned to effectively utilize the total system, constructed at then Nippon Mining's Mizushima Refinery, and thereby to establish the effective instrumentation techniques for commercial plants and to promote commercialization of these results. (NEDO)

  12. Malware Instrumentation Application to Regin Analysis

    Directory of Open Access Journals (Sweden)

    Matthieu Kaczmarek

    2015-12-01

    Full Text Available The complexity of the Regin malware underlines the importance of reverse engineering in modern incident response. The present study shows that such complexity can be overcome: substantial information about adversary tactics, techniques and procedures is obtained from reverse engineering. An introduction to the Regin development framework is provided along with instrumentation guidelines. Such instrumentation enables experimentation with malware modules. So analysis can derectly leverage malware’s own code without the need to program an analysis toolkit. As an application of the presented instrumentation, the underlying botnet architecture is analysed. Finally conclusions from different perspectives are provided: defense, attack and counter intelligence.

  13. Combustion and heat transfer monitoring in large utility boilers

    Energy Technology Data Exchange (ETDEWEB)

    Ignacio Diez, L.; Cortes, C.; Arauzo, I.; Valero, A. [Zaragoza Univ., Centro de Investigacion del rendimiento de Centrales Electricas (CIRCE) (Spain)

    2001-05-01

    As a result of the quick and vast development of instrumentation and software capabilities, the optimization and control of complex energy systems can presently take advantage of highly sophisticated engineering techniques, such as CFD calculations and correlation algorithms based on artificial intelligence concepts. However, the most advanced numerical prediction still relies on strong simplifications of the exact transport equations. Likewise, the output of a neural network, or any other refined data-processing device, is actually based in a long record of observed past responses. Therefore, the implementation of modern diagnosis tools generally requires a great amount of experimental data, in order to achieve an adequate validation of the method. Consequently, a sort of paradox results, since the validation data cannot be less accurate or complete than the predictions sought. To remedy this situation, there are several alternatives. In opposition to laboratory work or well-instrumented pilot plants, the information obtained in the full scale installation offers the advantages of realism and low cost. This paper presents the case-study of a large, pulverized-coal fired utility boiler, discussing both the evaluation of customary measurements and the adoption of supplementary instruments. The generic outcome is that it is possible to significantly improve the knowledge on combustion and heat transfer performance within a reasonable cost. Based on the experience and results, a general methodology is outlined to cope with this kind of analysis. (author)

  14. Product bundling, the key to a successful multi-utility strategy; Buendelung: Der Schluessel zu einer erfolgreichen Multi Utility-Strategie

    Energy Technology Data Exchange (ETDEWEB)

    Laker, M.; Nigge, K.M.; Wuebker, G. [Simon, Kucher und Partner Strategy and Marketing Consultants GmbH, Berlin (Germany)

    2002-04-01

    The article explains essential aspects of successful multi-utility management strategies for local utilities. Product bundling and the creation of incentives for enhancing the consumers' propensity to conclude multi-utility contracts, as e.g. pricing policy and the range of services that can be offered in a package are discussed. (orig./CB) [German] Das Thema Multi Utility, d.h. die Integration von Strom, Erdgas, Wasser, Entsorgung und Dienstleistungen wird ausfuehrlich diskutiert. Es muessen vielmehr Anreize dafuer geschaffen werden, dass die Kunden die Komplettangebote auch wahrnehmen. Dies ist eine Frage der Produkt- und Preisgestaltung. Buendelung ist das ideale Instrument zur Schaffung solcher Anreize. (orig./CB)

  15. Application of thin-film breakdown counters for characterization of neutron field of the VESUVIO instrument at the ISIS spallation source

    Science.gov (United States)

    Smirnov, A. N.; Pietropaolo, A.; Prokofiev, A. V.; Rodionova, E. E.; Frost, C. D.; Ansell, S.; Schooneveld, E. M.; Gorini, G.

    2012-09-01

    The high-energy neutron field of the VESUVIO instrument at the ISIS facility has been characterized using the technique of thin-film breakdown counters (TFBC). The technique utilizes neutron-induced fission reactions of natU and 209Bi with detection of fission fragments by TFBCs. Experimentally determined count rates of the fragments are ≈50% higher than those calculated using spectral neutron flux simulated with the MCNPX code. This work is a part of the project to develop ChipIr, a new dedicated facility for the accelerated testing of electronic components and systems for neutron-induced single event effects in the new Target Station 2 at ISIS. The TFBC technique has shown to be applicable for on-line monitoring of the neutron flux in the neutron energy range 1-800 MeV at the position of the device under test (DUT).

  16. Application of thin-film breakdown counters for characterization of neutron field of the VESUVIO instrument at the ISIS spallation source

    International Nuclear Information System (INIS)

    Smirnov, A.N.; Pietropaolo, A.; Prokofiev, A.V.; Rodionova, E.E.; Frost, C.D.; Ansell, S.; Schooneveld, E.M.; Gorini, G.

    2012-01-01

    The high-energy neutron field of the VESUVIO instrument at the ISIS facility has been characterized using the technique of thin-film breakdown counters (TFBC). The technique utilizes neutron-induced fission reactions of nat U and 209 Bi with detection of fission fragments by TFBCs. Experimentally determined count rates of the fragments are ≈50% higher than those calculated using spectral neutron flux simulated with the MCNPX code. This work is a part of the project to develop ChipIr, a new dedicated facility for the accelerated testing of electronic components and systems for neutron-induced single event effects in the new Target Station 2 at ISIS. The TFBC technique has shown to be applicable for on-line monitoring of the neutron flux in the neutron energy range 1–800 MeV at the position of the device under test (DUT).

  17. Measurement of utility.

    Science.gov (United States)

    Thavorncharoensap, Montarat

    2014-05-01

    The Quality Adjusted Life Year (QALY) is the most widely recommended health outcome measure for use in economic evaluations. The QALY gives a value to the effect of a given health intervention in terms of both quantity and quality. QALYs are calculated by multiplying the duration of time spent in a given health state, in years, by the quality of life weighted, known as utility. Utility can range from 0 (the worst health state-the equivalent of death) to 1 (the best health state-full health). This paper provides an overview of the various methods that can be used to measure utility and outlines the recommended protocol for measuring utility, as described in the Guidelines for Health Technology Assessment in Thailand (second edition). The recommendations are as follows: Wherever possible, primary data collection using EQ-5D-3L in patients using Thai value sets generated from the general public should be used. Where the EQ-5D-3L is considered inappropriate, other methods such as Standard gamble (SG), Time-trade-off (TTO), Visual analogue scale (VAS), Health Utilities Index (HUI), SF-6D, or Quality of well being (QWB) can be used. However, justification and full details on the chosen instrument should always be provided.

  18. Intercomparison of different instruments for measuring radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, Michikuni; Iida, Takao

    1990-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap method, a flow-type ionization chamber (pulse-counting method), a two-filter method, an electrostatic collection method and a passive integration radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq·m -3 (in outdoor air) to 110 Bq·m -3 (in indoor air). The results obtained by these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling method was about 52% of radon concentration. (author)

  19. Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation.

    Science.gov (United States)

    Guelzow, A; Stamm, O; Martus, P; Kielbassa, A M

    2005-10-01

    To compare ex vivo various parameters of root canal preparation using a manual technique and six different rotary nickel-titanium (Ni-Ti) instruments (FlexMaster, System GT, HERO 642, K3, ProTaper, and RaCe). A total of 147 extracted mandibular molars were divided into seven groups (n = 21) with equal mean mesio-buccal root canal curvatures (up to 70 degrees), and embedded in a muffle system. All root canals were prepared to size 30 using a crown-down preparation technique for the rotary nickel-titanium instruments and a standardized preparation (using reamers and Hedströem files) for the manual technique. Length modifications and straightening were determined by standardized radiography and a computer-aided difference measurement for every instrument system. Post-operative cross-sections were evaluated by light-microscopic investigation and photographic documentation. Procedural errors, working time and time for instrumentation were recorded. The data were analysed statistically using the Kruskal-Wallis test and the Mann-Whitney U-test. No significant differences were detected between the rotary Ni-Ti instruments for alteration of working length. All Ni-Ti systems maintained the original curvature well, with minor mean degrees of straightening ranging from 0.45 degrees (System GT) to 1.17 degrees (ProTaper). ProTaper had the lowest numbers of irregular post-operative root canal diameters; the results were comparable between the other systems. Instrument fractures occurred with ProTaper in three root canals, whilst preparation with System GT, HERO 642, K3 and the manual technique resulted in one fracture each. Ni-Ti instruments prepared canals more rapidly than the manual technique. The shortest time for instrumentation was achieved with System GT (11.7 s). Under the conditions of this ex vivo study all Ni-Ti systems maintained the canal curvature, were associated with few instrument fractures and were more rapid than a standardized manual technique. Pro

  20. Nondestructive assay instrument for measurement of plutonium in solutions

    International Nuclear Information System (INIS)

    Shirk, D.G.; Hsue, F.; Li, T.K.; Canada, T.R.

    1979-01-01

    A nondestructive assay (NDA) instrument that measures the 239 Pu content in solutions, using a passive gamma-ray spectroscopy technique, has been developed and installed in the LASL Plutonium Processing Facility. A detailed evaluation of this instrument has been performed. The results show that the instrument can routinely determine 239 Pu concentrations of 1 to 500 g/l with accuracies of 1 to 5% and assay times of 1 to 2 x 10 3 s

  1. Modern spinal instrumentation. Part 1: Normal spinal implants

    International Nuclear Information System (INIS)

    Davis, W.; Allouni, A.K.; Mankad, K.; Prezzi, D.; Elias, T.; Rankine, J.; Davagnanam, I.

    2013-01-01

    The general radiologist frequently encounters studies demonstrating spinal instrumentation, either as part of the patient's postoperative evaluation or as incidental to a study performed for another purpose. There are various surgical approaches and devices used in spinal surgery with an increased understanding of spinal and spinal implant biomechanics drives development of modern fixation devices. It is, therefore, important that the radiologist can recognize commonly used devices and identify their potential complications demonstrated on imaging. The aim of part 1 of this review is to familiarize the reader with terms used to describe surgical approaches to the spine, review the function and normal appearances of commonly used instrumentations, and understand the importance of the different fixation techniques. The second part of this review will concentrate on the roles that the different imaging techniques play in assessing the instrumented spine and the recognition of complications that can potentially occur.

  2. A new bridge technique for neutron tomography and diffraction measurements

    International Nuclear Information System (INIS)

    Burca, G.; James, J.A.; Kockelmann, W.; Fitzpatrick, M.E.; Zhang, S.Y.; Hovind, J.; Langh, R. van

    2011-01-01

    An attractive feature of neutron techniques is the ability to identify hidden materials and structures inside engineering components and objects of art and archaeology. Bearing this in mind we are investigating a new technique, 'Tomography Driven Diffraction' (TDD), that exploits tomography data to guide diffraction experiments on samples with complex structures and shapes. The technique can be used utilising combinations of individual tomography and diffraction instruments, such as NEUTRA (PSI, CH) and ENGIN-X (ISIS, UK), but is also suitable for new combined imaging and diffraction instruments such as the JEEP synchrotron engineering instrument (DIAMOND, UK) and the proposed IMAT neutron imaging and diffraction instrument (ISIS, UK).

  3. Dipole field measurement technique utilizing the Faraday rotation effect in polarization preserving optical fibers

    International Nuclear Information System (INIS)

    Haddock, C.; Tong, M.Y.M.

    1989-10-01

    TRIUMF is presently in the project definition stage of its proposed KAON factory. The facility will require approximately 300 dipole magnets. The rapid measurement of representative parameters of these magnets, in particular effective length, is one of the challenges to be met. As well as the commissioning of a.c magnetic field measurement systems based on established techniques a project is underway to investigate an alternative method utilizing the Faraday Rotation effect in polarization preserving optical fibers. It is shown that a fiber equivalent to a Faraday cell can be constructed by winding a fiber in a such a way that the induced beat length L p is equal to (2n+1) times the bending circumference, with n integer. Background to the subject and preliminary results of the measurements are reported in this paper

  4. The OCO-3 Mission: Science Objectives and Instrument Performance

    Science.gov (United States)

    Eldering, A.; Basilio, R. R.; Bennett, M. W.

    2017-12-01

    The Orbiting Carbon Observatory 3 (OCO-3) will continue global CO2 and solar-induced chlorophyll fluorescence (SIF) using the flight spare instrument from OCO-2. The instrument is currently being tested, and will be packaged for installation on the International Space Station (ISS) (launch readiness in early 2018.) This talk will focus on the science objectives, updated simulations of the science data products, and the outcome of recent instrument performance tests. The low-inclination ISS orbit lets OCO-3 sample the tropics and sub-tropics across the full range of daylight hours with dense observations at northern and southern mid-latitudes (+/- 52º). The combination of these dense CO2 and SIF measurements provides continuity of data for global flux estimates as well as a unique opportunity to address key deficiencies in our understanding of the global carbon cycle. The instrument utilizes an agile, 2-axis pointing mechanism (PMA), providing the capability to look towards the bright reflection from the ocean and validation targets. The PMA also allows for a snapshot mapping mode to collect dense datasets over 100km by 100km areas. Measurements over urban centers could aid in making estimates of fossil fuel CO2 emissions. Similarly, the snapshot mapping mode can be used to sample regions of interest for the terrestrial carbon cycle. In addition, there is potential to utilize data from ISS instruments ECOSTRESS (ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station) and GEDI (Global Ecosystem Dynamics Investigation), which measure other key variables of the control of carbon uptake by plants, to complement OCO-3 data in science analysis. In 2017, the OCO-2 instrument was transformed into the ISS-ready OCO-3 payload. The transformed instrument was thoroughly tested and characterized. Key characteristics, such as instrument ILS, spectral resolution, and radiometric performance will be described. Analysis of direct sun measurements taken during testing

  5. Optical, infrared and radio astronomy from techniques to observation

    CERN Document Server

    Poggiani, Rosa

    2017-01-01

    This textbook presents the established sciences of optical, infrared, and radio astronomy as distinct research areas, focusing on the science targets and the constraints that they place on instrumentation in the different domains. It aims to bridge the gap between specialized books and practical texts, presenting the state of the art in different techniques. For each type of astronomy, the discussion proceeds from the orders of magnitude for observable quantities that drive the building of instrumentation and the development of advanced techniques. The specific telescopes and detectors are then presented, together with the techniques used to measure fluxes and spectra. Finally, the instruments and their limits are discussed to assist readers in choice of setup, planning and execution of observations, and data reduction. The volume also includes worked examples and problem sets to improve student understanding; tables and figures in chapters summarize the state of the art of instrumentation and techniques.

  6. Avoidance-based human Pavlovian-to-instrumental transfer

    Science.gov (United States)

    Lewis, Andrea H.; Niznikiewicz, Michael A.; Delamater, Andrew R.; Delgado, Mauricio R.

    2013-01-01

    The Pavlovian-to-instrumental transfer (PIT) paradigm probes the influence of Pavlovian cues over instrumentally learned behavior. The paradigm has been used extensively to probe basic cognitive and motivational processes in studies of animal learning but, more recently, PIT and its underlying neural basis have been extended to investigations in humans. These initial neuroimaging studies of PIT have focused on the influence of appetitively conditioned stimuli on instrumental responses maintained by positive reinforcement, and highlight the involvement of the striatum. In the current study, we sought to understand the neural correlates of PIT in an aversive Pavlovian learning situation when instrumental responding was maintained through negative reinforcement. Participants exhibited specific PIT, wherein selective increases in instrumental responding to conditioned stimuli occurred when the stimulus signaled a specific aversive outcome whose omission negatively reinforced the instrumental response. Additionally, a general PIT effect was observed such that when a stimulus was associated with a different aversive outcome than was used to negatively reinforce instrumental behavior, the presence of that stimulus caused a non-selective increase in overall instrumental responding. Both specific and general PIT behavioral effects correlated with increased activation in corticostriatal circuitry, particularly in the striatum, a region involved in cognitive and motivational processes. These results suggest that avoidance-based PIT utilizes a similar neural mechanism to that seen with PIT in an appetitive context, which has implications for understanding mechanisms of drug-seeking behavior during addiction and relapse. PMID:24118624

  7. Developing and Testing a New Measurement Instrument for Documenting Instrumental Knowledge Utilisation: The Degrees of Knowledge Utilization (DoKU) Scale

    Science.gov (United States)

    Bøllingtoft Knudsen, Søren

    2018-01-01

    Focus on evidence-based policymaking is greater than ever, and public spending on evaluations is rising. A primary merit of these expenditures is that politicians actually use new knowledge instrumentally--to influence and inform decision making. Nevertheless, we know surprisingly little about whether and how research-based knowledge is utilised.…

  8. Pulsed neutron source and instruments at neutron facility

    Energy Technology Data Exchange (ETDEWEB)

    Teshigawara, Makoto; Aizawa, Kazuya; Suzuki, Jun-ichi; Morii, Yukio; Watanabe, Noboru [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-11-01

    We report the results of design studies on the optimal target shape, target - moderator coupling, optimal layout of moderators, and neutron instruments for a next generation pulsed spallation source in JAERI. The source utilizes a projected high-intensity proton accelerator (linac: 1.5 GeV, {approx}8 MW in total beam power, compressor ring: {approx}5 MW). We discuss the target neutronics, moderators and their layout. The sources is designed to have at least 30 beam lines equipped with more than 40 instruments, which are selected tentatively to the present knowledge. (author)

  9. Performance and quality control of nuclear medicine instrumentation

    International Nuclear Information System (INIS)

    Paras, P.

    1981-01-01

    The status and the recent developments of nuclear medicine instrumentation performance, with an emphasis on gamma-camera performance, are discussed as the basis for quality control. New phantoms and techniques for the measurement of gamma-camera performance parameters are introduced and their usefulness for quality control is discussed. Tests and procedures for dose calibrator quality control are included. Also, the principles of quality control, tests, equipment and procedures for each type of instrument are reviewed, and minimum requirements for an effective quality assurance programme for nuclear medicine instrumentation are suggested. (author)

  10. Approaches of High School Instrumental Music Educators in Response to Student Challenges

    Science.gov (United States)

    Edgar, Scott N.

    2016-01-01

    The purpose of this multiple instrumental case study was to explore approaches of four high school instrumental music educators assuming the role of facilitative teacher in responding to challenges affecting the social and emotional well-being of their students. This study utilized the framework of social emotional learning as a lens to view the…

  11. Prediction method of unburnt carbon for coal fired utility boiler using image processing technique of combustion flame

    International Nuclear Information System (INIS)

    Shimoda, M.; Sugano, A.; Kimura, T.; Watanabe, Y.; Ishiyama, K.

    1990-01-01

    This paper reports on a method predicting unburnt carbon in a coal fired utility boiler developed using an image processing technique. The method consists of an image processing unit and a furnace model unit. temperature distribution of combustion flames can be obtained through the former unit. The later calculates dynamics of the carbon reduction from the burner stages to the furnace outlet using coal feed rate, air flow rate, chemical and ash content of coal. An experimental study shows that the prediction error of the unburnt carbon can be reduced to 10%

  12. Existing and new techniques in uranium exploration

    International Nuclear Information System (INIS)

    Bowie, S.H.U.; Cameron, J.

    1976-01-01

    The demands on uranium exploration over the next 25 years will be very great indeed and will call for every possible means of improvement in exploration capability. The first essential is to increase geological knowledge of the mode of occurrence of uranium ore deposits. The second is to improve existing exploration techniques and instrumentation while, at the same time, promoting research and development on new methods to discover uranium ore bodies on the earth's surface and at depth. The present symposium is an effort to increase co-operation and the exchange of information in the critical field of uranium exploration techniques and instrumentation. As an introduction to the symposium a brief review is presented, firstly of what can be considered as existing techniques and, secondly, of techniques which have not yet been used on an appreciable scale. Some fourteen techniques used over the last 30 years are identified and their appropriate application, advantages and limitations are briefly summarized and the possibilities of their further development considered. The aim of future research on new techniques, in addition to finding new ways and means of identifying surface deposits, should be mainly directed to devising methods and instrumentation capable of detecting buried ore bodies that do not give a gamma signal at the surface. To achieve this aim, two contributory factors are essential: adequate financial support for research and development and increased specialized training in uranium exploration and instrumentation design. The papers in this symposium describe developments in the existing techniques, proposals for future research and development and case histories of exploration programmes

  13. Comparison of non-invasive tear film stability measurement techniques.

    Science.gov (United States)

    Wang, Michael Tm; Murphy, Paul J; Blades, Kenneth J; Craig, Jennifer P

    2018-01-01

    Measurement of tear film stability is commonly used to give an indication of tear film quality but a number of non-invasive techniques exists within the clinical setting. This study sought to compare three non-invasive tear film stability measurement techniques: instrument-mounted wide-field white light clinical interferometry, instrument-mounted keratoscopy and hand-held keratoscopy. Twenty-two subjects were recruited in a prospective, randomised, masked, cross-over study. Tear film break-up or thinning time was measured non-invasively by independent experienced examiners, with each of the three devices, in a randomised order, within an hour. Significant correlation was observed between instrument-mounted interferometric and keratoscopic measurements (p 0.05). Tear film stability values obtained from the hand-held device were significantly shorter and demonstrated narrower spread than the other two instruments (all p 0.05). Good clinical agreement exists between the instrument-mounted interferometric and keratoscopic measurements but not between the hand-held device and either of the instrument-mounted techniques. The results highlight the importance of specifying the instrument employed to record non-invasive tear film stability. © 2017 Optometry Australia.

  14. Factors affecting utilization of university health services in a tertiary institution in South-West Nigeria.

    Science.gov (United States)

    Obiechina, G O; Ekenedo, G O

    2013-01-01

    Most university health services have extensive health infrastructures, for the provision of effective and efficient health services to the students. In this study, we have tried to determine student's perception of factors affecting their utilization. To determine students' perception of health care services provided in a tertiary institution and assess students' attitude towards utilization. Simple random sampling technique was used to select 540 respondents, comprising of 390 males and 150 females. A structured and self-administered questionnaire was the instrument used to collect data for the study, while data collected was analyzed using descriptive statistics of frequency count and percentage. High cost of drugs (72.0%), non availability of essential drugs (54.8%), time spent waiting for treatment (67.2%), inadequate referral services (81.7%), and satisfaction with services (60.6%) were considered by the respondents as factors affecting the utilization of university health services. Students-medical staff relationship and accessibility to health facility (77.6% and 74.3% respectively) were, however, not considered as factors that affect utilization of university health services. It is recommended that to improve utilization and cost of care, government should make necessary efforts to incorporate tertiary institution into National Health Insurance scheme so that students above the age of 18 years can benefit from free treatment.

  15. Efficacy of different instrumentation techniques on reducing Enterococcus faecalis infection in experimentally infected root canals

    Directory of Open Access Journals (Sweden)

    Ebru Özsezer Demiryürek

    2014-03-01

    Conclusion: This study indicates that instruments with a greater taper play an important role in maximizing the effectiveness of mechanical preparation. However, since using mechanical instrumentation alone is insufficient to completely eliminate root canal infection, the use of complementary antibacterial compounds is necessary.

  16. Particle size distribution instrument. Topical report 13

    Energy Technology Data Exchange (ETDEWEB)

    Okhuysen, W.; Gassaway, J.D.

    1995-04-01

    The development of an instrument to measure the concentration of particles in gas is described in this report. An in situ instrument was designed and constructed which sizes individual particles and counts the number of occurrences for several size classes. Although this instrument was designed to detect the size distribution of slag and seed particles generated at an experimental coal-fired magnetohydrodynamic power facility, it can be used as a nonintrusive diagnostic tool for other hostile industrial processes involving the formation and growth of particulates. Two of the techniques developed are extensions of the widely used crossed beam velocimeter, providing simultaneous measurement of the size distribution and velocity of articles.

  17. Fuel cell-based instrumentation for ethanol determination in alcoholic beverages, fermentations, and biofluids

    Energy Technology Data Exchange (ETDEWEB)

    Parry, K W

    1988-01-01

    The main aim of this project was to devise an alternative method for ethanol assay, employing an electrochemical fuel cell sensor. Thus, the early part of this thesis describes the work carried out in the development of a new analytical technique for this purpose. This work resulted in the production of a successful prototype unit which has led to the development of a commercial instrument, vis., the Lion Drinks Alcolmeter (DA-1) available from Lion Laboratories Ltd. The problem of determining the ethanol content of a fermenting liquor at any point during a fermentation process was also broached and a novel technique combining a flow dilution system, dynamic headspace analysis and a fuel cell sensor was developed. This procedure, suitably automated, will enable the ethanolic content of a fermenting beverage to be determined at any stage during a fermentation, the results obtained in this manner being in excellent agreement with those obtained gas chromatographically. Methods of extending the linear working range of a fuel cell-based sampling system are reported in the hope that the encouraging results obtained may initiate further progress in this field. Finally, the sensing system used in this work has also been utilized with an alternative sampling procedure for the determination of ethanol in biological fluids, mainly for clinical and forensic applications. This work has also led to the production of a commercial instrument, viz. the Lion AE-D3 Alcolmeter.

  18. Deformation of HyFlex CM instruments and their shape recovery following heat sterilization.

    Science.gov (United States)

    Alfoqom Alazemi, M; Bryant, S T; Dummer, P M H

    2015-06-01

    To assess the deformation of HyFlex CM instruments (Coltene Whaledent) when used in two instrumentation sequences and to assess their shape recovery after heat sterilization. Simulated root canals with four different shapes were prepared with HyFlex CM instruments using a single-length technique (n = 40) or a crown down technique (n = 40). Pre-preparation, post-preparation and post-sterilization standardized images of each instrument were recorded. Assessment of instrument deformation and their subsequent shape recovery was carried out visually and by comparing the digitised images. Data analysis was carried out using chi-square tests. None of the 400 instruments fractured. Visual assessment of instruments post-preparation revealed that 30.5% had unwound and 0.5% had reverse winding. Following sterilization 8.5% remained unwound and 0.5% remained with reverse winding. When assessing instrument shape using digital images, 35.25% were unwound post-preparation, which reduced to 11% post-sterilization. Nine size 25, 0.08 instruments deformed, but none fully regained their original shape after sterilization; however, other sizes of deformed instruments did regain their shape (P recovery. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  19. IOT Overview: Calibrations of the VLTI Instruments (MIDI and AMBER)

    Science.gov (United States)

    Morel, S.; Rantakyrö, F.; Rivinius, T.; Stefl, S.; Hummel, C.; Brillant, S.; Schöller, M.; Percheron, I.; Wittkowski, M.; Richichi, A.; Ballester, P.

    We present here a short review of the calibration processes that are currently applied to the instruments AMBER and MIDI of the VLTI (Very Large Telescope Interferometer) at Paranal. We first introduce the general principles to calibrate the raw data (the "visibilities") that have been measured by long-baseline optical interferometry. Then, we focus on the specific case of the scientific operation of the VLTI instruments. We explain the criteria that have been used to select calibrator stars for the observations with the VLTI instruments, as well as the routine internal calibration techniques. Among these techniques, the "P2VM" (Pixel-to-Visibility Matrix) in the case of AMBER is explained. Also, the daily monitoring of AMBER and MIDI, that has recently been implemented, is shortly introduced.

  20. Benefits of using customized instrumentation in total knee arthroplasty: results from an activity-based costing model.

    Science.gov (United States)

    Tibesku, Carsten O; Hofer, Pamela; Portegies, Wesley; Ruys, C J M; Fennema, Peter

    2013-03-01

    The growing demand for total knee arthroplasty (TKA) associated with the efforts to contain healthcare expenditure by advanced economies necessitates the use of economically effective technologies in TKA. The present analysis based on activity-based costing (ABC) model was carried out to estimate the economic value of patient-matched instrumentation (PMI) compared to standard surgical instrumentation in TKA. The costs of the two approaches, PMI and standard instrumentation in TKA, were determined by the use of ABC which measures the cost of a particular procedure by determining the activities involved and adding the cost of each activity. Improvement in productivity due to increased operating room (OR) turn-around times was determined and potential additional revenue to the hospital by the efficient utilization of gained OR time was estimated. Increased efficiency in the usage of OR and utilization of surgical trays were noted with patient-specific approach. Potential revenues to the hospital were estimated with the use of PMI by efficient utilization of time saved in OR. Additional revenues of 78,240 per year were estimated considering utilization of gained OR time to perform surgeries other than TKA. The analysis suggests that use of PMI in TKA is economically effective when compared to standard instrumentation.

  1. Status of the Neutron Imaging and Diffraction Instrument IMAT

    Science.gov (United States)

    Kockelmann, Winfried; Burca, Genoveva; Kelleher, Joe F.; Kabra, Saurabh; Zhang, Shu-Yan; Rhodes, Nigel J.; Schooneveld, Erik M.; Sykora, Jeff; Pooley, Daniel E.; Nightingale, Jim B.; Aliotta, Francesco; Ponterio, Rosa C.; Salvato, Gabriele; Tresoldi, Dario; Vasi, Cirino; McPhate, Jason B.; Tremsin, Anton S.

    A cold neutron imaging and diffraction instrument, IMAT, is currently being constructed at the ISIS second target station. IMAT will capitalize on time-of-flight transmission and diffraction techniques available at a pulsed neutron source. Analytical techniques will include neutron radiography, neutron tomography, energy-selective neutron imaging, and spatially resolved diffraction scans for residual strain and texture determination. Commissioning of the instrument will start in 2015, with time-resolving imaging detectors and two diffraction detector prototype modules. IMAT will be operated as a user facility for material science applications and will be open for developments of time-of-flight imaging methods.

  2. Instrumentation qualification. Seismic qualification of C-E instrumentation equipment. Part One

    International Nuclear Information System (INIS)

    1977-05-01

    A summary of the C-E seismic qualification program utilized to demonstrate the seismic design adequacy of the instrumentation and control equipment used in C-E supplied Nuclear Steam Supply Systems (NSSS) is presented. The report is divided into two parts. Part One includes the equipment seismic requirements and a description of the qualification methods. Part Two lists the specific equipment by nuclear station in which it is used and the equipment test results are summarized in a standard data sheet format to facilitate review. The seismic requirements are based on individual contract commitments with C-E customers and the NRC Standard Review Plan, Section 3.10 ''Seismic Qualification of Category I Instrumentation and Electrical Equipment.'' Equipment is qualified for use in a seismic environment where damage potential to the equipment is less than or equal to that simulated seismic environment to which it has been qualified. The anticipated Safe Shutdown Earthquake (SSE) environment at the inservice location of equipment should be confirmed by each applicant as not exceeding that to which it is qualified

  3. Solvent Front Position Extraction procedure with thin-layer chromatography as a mode of multicomponent sample preparation for quantitative analysis by instrumental technique.

    Science.gov (United States)

    Klimek-Turek, A; Sikora, E; Dzido, T H

    2017-12-29

    A concept of using thin-layer chromatography to multicomponent sample preparation for quantitative determination of solutes followed by instrumental technique is presented. Thin-layer chromatography (TLC) is used to separate chosen substances and their internal standard from other components (matrix) and to form a single spot/zone containing them at the solvent front position. The location of the analytes and internal standard in the solvent front zone allows their easy extraction followed by quantitation by HPLC. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Measurement of sexual functioning after spinal cord injury: preferred instruments

    DEFF Research Database (Denmark)

    Alexander, Marcalee Sipski; Brackett, Nancy L; Bodner, Donald

    2009-01-01

    into male and female sexual function, male reproductive function, and female reproductive function. The instruments that have been used most frequently to measure these aspects of sexual function over the past 5 years were identified by expert consensus. Finally, these instruments were subjected...... to a critical review. RESULTS: The Female Sexual Function Index (FSFI), measurement of vaginal pulse amplitude (VPA), the International Index of Erectile Function (IIEF), and the measurement of ejaculatory function and semen quality were considered appropriate measures to assess sexual responses......BACKGROUND/OBJECTIVE: To determine the utility of certain instruments to assess sexuality and fertility after SCI, an expert panel identified key areas to study and evaluated available instruments. These were rated according to certain predefined criteria. METHODS: The authors divided sexual issues...

  5. A comparative study of sample dissolution techniques and plasma-based instruments for the precise and accurate quantification of REEs in mineral matrices

    International Nuclear Information System (INIS)

    Whitty-Léveillé, Laurence; Turgeon, Keven; Bazin, Claude; Larivière, Dominic

    2017-01-01

    The recent commercialisation of inductively coupled plasma tandem mass spectrometric (ICP-MS/MS) instruments has provided analytical chemists with a new tool to properly quantify atomic composition in a variety of matrices with minimal sample preparation. In this article, we report on our assessment of the compatibility of 3 sample preparation techniques (open-vessel acid digestion, microwave digestion and alkaline fusion) for the quantification of rare earth elements (REEs) in mineral matrices. The combination of the high digestion temperatures (1050 °C) and using LiBO_2 as a flux was the most effective strategy for the digestion of all rare earth elements in mineral matrices and was compatible with ICP-MS/MS measurements. We also assessed the analytical performances of ICP-MS/MS against other plasma-based instrumentation (microwave induced plasma and inductively coupled plasma atomic emission spectroscopy (MIP-AES and ICP-AES, respectively) and single quadrupole inductively coupled plasma mass spectrometry (ICP-MS). The comparative study showed that the concentrations obtained by ICP-MS/MS are in excellent agreement with the certified reference material values, and much more suited than the other analytical techniques tested for the quantification of REEs, which exhibited low detectability and/or spectral interferences for some elements/isotopes. Finally, the ruggedness of the analytical protocol proposed which combines a rapid sample dissolution step performed by an automated fusion unit and an ICP-MS/MS as a detector was established using various certified mineral matrices containing variable levels of REEs. - Highlights: • Three types of digestion methods were tested. • Four types of analytical techniques were compared. • Elimination of the spectral interferences encountered in ICP-MS was achieved by the use of Tandem ICP-MS. • Robustness of the analytical procedure was successfully evaluate on four types of certified reference material.

  6. A comparative study of sample dissolution techniques and plasma-based instruments for the precise and accurate quantification of REEs in mineral matrices

    Energy Technology Data Exchange (ETDEWEB)

    Whitty-Léveillé, Laurence; Turgeon, Keven [Département de génie des mines, de la métallurgie et des matériaux, Université Laval, Québec, QC (Canada); Département de chimie, Université Laval, Québec, QC (Canada); Bazin, Claude [Département de génie des mines, de la métallurgie et des matériaux, Université Laval, Québec, QC (Canada); Larivière, Dominic, E-mail: dominic.lariviere@chm.ulaval.ca [Département de chimie, Université Laval, Québec, QC (Canada)

    2017-04-08

    The recent commercialisation of inductively coupled plasma tandem mass spectrometric (ICP-MS/MS) instruments has provided analytical chemists with a new tool to properly quantify atomic composition in a variety of matrices with minimal sample preparation. In this article, we report on our assessment of the compatibility of 3 sample preparation techniques (open-vessel acid digestion, microwave digestion and alkaline fusion) for the quantification of rare earth elements (REEs) in mineral matrices. The combination of the high digestion temperatures (1050 °C) and using LiBO{sub 2} as a flux was the most effective strategy for the digestion of all rare earth elements in mineral matrices and was compatible with ICP-MS/MS measurements. We also assessed the analytical performances of ICP-MS/MS against other plasma-based instrumentation (microwave induced plasma and inductively coupled plasma atomic emission spectroscopy (MIP-AES and ICP-AES, respectively) and single quadrupole inductively coupled plasma mass spectrometry (ICP-MS). The comparative study showed that the concentrations obtained by ICP-MS/MS are in excellent agreement with the certified reference material values, and much more suited than the other analytical techniques tested for the quantification of REEs, which exhibited low detectability and/or spectral interferences for some elements/isotopes. Finally, the ruggedness of the analytical protocol proposed which combines a rapid sample dissolution step performed by an automated fusion unit and an ICP-MS/MS as a detector was established using various certified mineral matrices containing variable levels of REEs. - Highlights: • Three types of digestion methods were tested. • Four types of analytical techniques were compared. • Elimination of the spectral interferences encountered in ICP-MS was achieved by the use of Tandem ICP-MS. • Robustness of the analytical procedure was successfully evaluate on four types of certified reference material.

  7. Research and development of radiation utilizations in 1981 at JAERI

    International Nuclear Information System (INIS)

    1981-01-01

    There is the field of radiation utilization such as the application of the effect of radiation on matters and the techniques of measurement and analysis utilizing the properties of radiation, in addition to the use of atomic energy as heat or electric power. The fields of application of radiation utilization are very wide, and are closely related to the health and daily life of people. The Japan Atomic Energy Research Institute has performed the research and development on radiation utilization regarding radiochemistry, the application of irradiation, and the production and industrial utilization of radioisotopes. Also, the research of the radiation resistance of organic materials used for nuclear facilities, the development of organic materials, and the production of tritium have become necessary. In this booklet, the recent results of radiation utilization in the JAERI are summarized. The research and development of ion exchange membranes, organic glasses, the fixation of living body activators and water paints, the techniques of utilizing irradiation, the techniques of radioisotope productions and utilization, and the techniques related to the development of atomic energy are reported. (Kako, I.)

  8. Combustion and heat transfer monitoring in large utility boilers

    Energy Technology Data Exchange (ETDEWEB)

    Diez, L.I.; Cortes, C.; Arauzo, I.; Valero, A. [University of Zaragoza, Zaragoza (Spain). Center of Power Plant Efficiency Research

    2001-05-01

    The optimization and control of complex energy systems can presently take advantage of highly sophisticated engineering techniques, such as CFD calculations and correlation algorithms based on artificial intelligence concepts. However, the most advanced numerical prediction still relies on strong simplifications of the exact transport equations. Likewise, the output of a neural network is actually based on a long record of observed past responses. Therefore, the implementation of modern diagnosis tools generally requires a great amount of experimental data, in order to achieve an adequate validation of the method. Consequently, a sort of paradox results, since the validation data cannot be less accurate or complete than the predictions sought. To remedy this situation, there are several alternatives. In contrast to laboratory work or well-instrumented pilot plants, the information obtained in the full scale installation offers the advantages of realism and low cost. This paper presents the case-study of a large, pulverized-coal fired utility boiler, discussing both the evaluation of customary measurements and the adoption of supplementary instruments. The generic outcome is that it is possible to significantly improve the knowledge on combustion and heat transfer performance within a reasonable cost. Based on the experience and results, a general methodology is outlined to cope with this kind of analysis.

  9. High-Performance Operational and Instrumentation Amplifiers

    NARCIS (Netherlands)

    Shahi, B.

    2015-01-01

    This thesis describes techniques to reduce the offset error in precision instrumentation and operational amplifiers. The offset error which is considered a major error source associated with gain blocks, together with other errors are reviewed. Conventional and newer approaches to remove offset and

  10. Advances in Miniaturized Instruments for Genomics

    Directory of Open Access Journals (Sweden)

    Cihun-Siyong Alex Gong

    2014-01-01

    Full Text Available In recent years, a lot of demonstrations of the miniaturized instruments were reported for genomic applications. They provided the advantages of miniaturization, automation, sensitivity, and specificity for the development of point-of-care diagnostics. The aim of this paper is to report on recent developments on miniaturized instruments for genomic applications. Based on the mature development of microfabrication, microfluidic systems have been demonstrated for various genomic detections. Since one of the objectives of miniaturized instruments is for the development of point-of-care device, impedimetric detection is found to be a promising technique for this purpose. An in-depth discussion of the impedimetric circuits and systems will be included to provide total consideration of the miniaturized instruments and their potential application towards real-time portable imaging in the “-omics” era. The current excellent demonstrations suggest a solid foundation for the development of practical and widespread point-of-care genomic diagnostic devices.

  11. Developing a Research Instrument to Document Awareness, Knowledge, and Attitudes Regarding Breast Cancer and Early Detection Techniques for Pakistani Women: The Breast Cancer Inventory (BCI).

    Science.gov (United States)

    Naqvi, Atta Abbas; Zehra, Fatima; Ahmad, Rizwan; Ahmad, Niyaz

    2016-12-09

    There is a general hesitation in participation among Pakistani women when it comes to giving their responses in surveys related to breast cancer which may be due to the associated stigma and conservatism in society. We felt that no research instrument was able to extract information from the respondents to the extent it was needed for the successful execution of our study. The need to develop a research instrument tailored for Pakistani women was based upon the fact that most Pakistani women come from a conservative background and sometimes view this topic as provocative and believe discussing publicly about it as inappropriate. Existing research instruments exhibited a number of weaknesses during literature review. Therefore, using them may not be able to extract information concretely. A research instrument was, thus, developed exclusively. It was coined as, "breast cancer inventory (BCI)" by a panel of experts for executing a study aimed at documenting awareness, knowledge, and attitudes of Pakistani women regarding breast cancer and early detection techniques. The study is still in the data collection phase. The statistical analysis involved the Kaiser-Meyer-Olkin (KMO) measure and Bartlett's test for sampling adequacy. In addition, reliability analysis and exploratory factor analysis (EFA) were, also employed. This concept paper focuses on the development, piloting and validation of the BCI. It is the first research instrument which has high acceptability among Pakistani women and is able to extract adequate information from the respondents without causing embarrassment or unease.

  12. Application of thin-film breakdown counters for characterization of neutron field of the VESUVIO instrument at the ISIS spallation source

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, A.N. [V.G. Khlopin Radium Institute, St. Petersburg (Russian Federation); Pietropaolo, A., E-mail: antonino.pietropaolo@roma2.infn.it [CNISM UdR Tor Vergata, and Centro NAST Roma, Italy Scientifica 1 I-00133 Roma Italy (Italy); Prokofiev, A.V. [The Svedberg Laboratory, Uppsala University, Uppsala (Sweden); Rodionova, E.E. [V.G. Khlopin Radium Institute, St. Petersburg (Russian Federation); Frost, C.D.; Ansell, S.; Schooneveld, E.M. [ISIS Facility, Rutherford Appleton Laboratory, Chilton (United Kingdom); Gorini, G. [Dipartimento di Fisica ' G. Occhialini,' Universita degli Studi di Milano-Bicocca, Milano (Italy)

    2012-09-21

    The high-energy neutron field of the VESUVIO instrument at the ISIS facility has been characterized using the technique of thin-film breakdown counters (TFBC). The technique utilizes neutron-induced fission reactions of {sup nat}U and {sup 209}Bi with detection of fission fragments by TFBCs. Experimentally determined count rates of the fragments are Almost-Equal-To 50% higher than those calculated using spectral neutron flux simulated with the MCNPX code. This work is a part of the project to develop ChipIr, a new dedicated facility for the accelerated testing of electronic components and systems for neutron-induced single event effects in the new Target Station 2 at ISIS. The TFBC technique has shown to be applicable for on-line monitoring of the neutron flux in the neutron energy range 1-800 MeV at the position of the device under test (DUT).

  13. German activities in optical space instrumentation

    Science.gov (United States)

    Hartmann, G.

    2018-04-01

    In the years of space exploration since the mid-sixties, a wide experience in optical space instrumentation has developed in Germany. This experience ranges from large telescopes in the 1 m and larger category with the accompanying focal plane detectors and spectrometers for all regimes of the electromagnetic spectrum (infrared, visible, ultraviolet, x-rays), to miniature cameras for cometary and planetary explorations. The technologies originally developed for space science. are now also utilized in the fields of earth observation and even optical telecommunication. The presentation will cover all these areas, with examples for specific technological or scientific highlights. Special emphasis will be given to the current state-of-the-art instrumentation technologies in scientific institutions and industry, and to the future perspective in approved and planned projects.

  14. Portable instrument for in-vivo infrared oxymetry using spread-spectrum modulation

    Energy Technology Data Exchange (ETDEWEB)

    Trevisan, S [Dipartimento di Elettronica, Universita di Pavia, Pavia, Via Ferrata, 1 - 27100 Pavia (Italy); Bavera, M [National Institute for the Physics of Matter, INFM, C.so Perrone, 24 - 16152 Genova (Italy); Giardini, M E [National Institute for the Physics of Matter, INFM, C.so Perrone, 24 - 16152 Genova (Italy)

    2007-04-15

    Near Infrared Spectroscopy (NIRS) can be employed to monitor noninvasively and continuously local changes in hemodynamics and oxygenation of human tissues. A portable NIRS research-grade acquisition system, dedicated to measurements during muscular exercise, is presented. The instrument is able to control up to eight LED sources and two detectors. A digital correlation technique, implemented on a single-chip RISC microcontroller, performs source-to-detector multiplexing. Such algorithm is highly optimized for computational efficiency and ambient noise rejection. Software-configurable input stages allow for flexibility in instrument setup. As a result of the specific correlation technique employed, the instrument is compact, lightweight and efficient. Clinical tests on oxygen consumption show excellent performance.

  15. Portable instrument for in-vivo infrared oxymetry using spread-spectrum modulation

    International Nuclear Information System (INIS)

    Trevisan, S; Bavera, M; Giardini, M E

    2007-01-01

    Near Infrared Spectroscopy (NIRS) can be employed to monitor noninvasively and continuously local changes in hemodynamics and oxygenation of human tissues. A portable NIRS research-grade acquisition system, dedicated to measurements during muscular exercise, is presented. The instrument is able to control up to eight LED sources and two detectors. A digital correlation technique, implemented on a single-chip RISC microcontroller, performs source-to-detector multiplexing. Such algorithm is highly optimized for computational efficiency and ambient noise rejection. Software-configurable input stages allow for flexibility in instrument setup. As a result of the specific correlation technique employed, the instrument is compact, lightweight and efficient. Clinical tests on oxygen consumption show excellent performance

  16. Instrumentation and quantitative methods of evaluation. Progress report, January 15-September 14, 1986

    International Nuclear Information System (INIS)

    Beck, R.N.

    1986-09-01

    This document reports progress under grant entitled ''Instrumentation and Quantitative Methods of Evaluation.'' Individual reports are presented on projects entitled the physical aspects of radionuclide imaging, image reconstruction and quantitative evaluation, PET-related instrumentation for improved quantitation, improvements in the FMI cyclotron for increased utilization, and methodology for quantitative evaluation of diagnostic performance

  17. Increased Science Instrumentation Funding Strengthens Mars Program

    Science.gov (United States)

    Graham, Lee D.; Graff, T. G.

    2012-01-01

    As the strategic knowledge gaps mature for the exploration of Mars, Mars sample return (MSR), and Phobos/Deimos missions, one approach that becomes more probable involves smaller science instrumentation and integrated science suites. Recent technological advances provide the foundation for a significant evolution of instrumentation; however, the funding support is currently too small to fully utilize these advances. We propose that an increase in funding for instrumentation development occur in the near-term so that these foundational technologies can be applied. These instruments would directly address the significant knowledge gaps for humans to Mars orbit, humans to the Martian surface, and humans to Phobos/ Deimos. They would also address the topics covered by the Decadal Survey and the Mars scientific goals, objectives, investigations and priorities as stated by the MEPAG. We argue that an increase of science instrumentation funding would be of great benefit to the Mars program as well as the potential for human exploration of the Mars system. If the total non-Earth-related planetary science instrumentation budget were increased 100% it would not add an appreciable amount to the overall NASA budget and would provide the real potential for future breakthroughs. If such an approach were implemented in the near-term, NASA would benefit greatly in terms of science knowledge of the Mars, Phobos/Deimos system, exploration risk mitigation, technology development, and public interest.

  18. Error reduction techniques for measuring long synchrotron mirrors

    International Nuclear Information System (INIS)

    Irick, S.

    1998-07-01

    Many instruments and techniques are used for measuring long mirror surfaces. A Fizeau interferometer may be used to measure mirrors much longer than the interferometer aperture size by using grazing incidence at the mirror surface and analyzing the light reflected from a flat end mirror. Advantages of this technique are data acquisition speed and use of a common instrument. Disadvantages are reduced sampling interval, uncertainty of tangential position, and sagittal/tangential aspect ratio other than unity. Also, deep aspheric surfaces cannot be measured on a Fizeau interferometer without a specially made fringe nulling holographic plate. Other scanning instruments have been developed for measuring height, slope, or curvature profiles of the surface, but lack accuracy for very long scans required for X-ray synchrotron mirrors. The Long Trace Profiler (LTP) was developed specifically for long x-ray mirror measurement, and still outperforms other instruments, especially for aspheres. Thus, this paper focuses on error reduction techniques for the LTP

  19. Development of Processing Techniques for Advanced Thermal Protection Materials

    Science.gov (United States)

    Selvaduray, Guna; Cox, Michael; Srinivasan, Vijayakumar

    1997-01-01

    Thermal Protection Materials Branch (TPMB) has been involved in various research programs to improve the properties and structural integrity of the existing aerospace high temperature materials. Specimens from various research programs were brought into the analytical laboratory for the purpose of obtaining and refining the material characterization. The analytical laboratory in TPMB has many different instruments which were utilized to determine the physical and chemical characteristics of materials. Some of the instruments that were utilized by the SJSU students are: Scanning Electron Microscopy (SEM), Energy Dispersive X-ray analysis (EDX), X-ray Diffraction Spectrometer (XRD), Fourier Transform-Infrared Spectroscopy (FTIR), Ultra Violet Spectroscopy/Visible Spectroscopy (UV/VIS), Particle Size Analyzer (PSA), and Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES). The above mentioned analytical instruments were utilized in the material characterization process of the specimens from research programs such as: aerogel ceramics (I) and (II), X-33 Blankets, ARC-Jet specimens, QUICFIX specimens and gas permeability of lightweight ceramic ablators. In addition to analytical instruments in the analytical laboratory at TPMB, there are several on-going experiments. One particular experiment allows the measurement of permeability of ceramic ablators. From these measurements, physical characteristics of the ceramic ablators can be derived.

  20. Effect of applying wheat stubble on preservation and utilization of n-fertilizer by 15N trace technique

    International Nuclear Information System (INIS)

    Xu Xinyu; Zhang Yumei; Xiang Hua; Hu Jisheng

    1991-10-01

    By using 15 N trace technique, the effect of applying wheat stubble on the preservation and utilization rate of 15 N- ammonium sulphate have been studied. The abundance of ( 15 NH 4 ) 2 SO 4 fertilizer was 8.92%. After three years pot test and field plot test, the results showed that the yields with ' 15 N+mulching' and ' 15 N+incorporating' treated were increased by 5.4∼30.0% for spring wheat and millet(pot test), and 18∼23% for winter wheat and summer corn(field plot test), as compared with only ' 15 N' treatment. The results of 15 N-fertilizer labelled tests showed that the utilization rates of 15 N-fertilizer treated by ' 15 N+mulching' for cropping seasons were 57.8%, 65.8%, 36.6% and 8.5% respectively. These were increased 3.7%, 10.2%, 21.5% and 2.8% as compared with only ' 15 N' treatment. Comparing with only ' 15 N'treatment, the N leached off by percolation water was decreasing 50%, the loss of N caused by volatilization was decreasing 30.3% and the N in humus was increasing 21.1%. All of these proved that the applying of wheat stubble in different mode would adjust and control the activation of microbe in the soil, and the preservation and utilization rate of fertilizer in the soul would be increased

  1. Instrumental Variables in the Long Run

    DEFF Research Database (Denmark)

    Casey, Gregory; Klemp, Marc Patrick Brag

    2017-01-01

    In the study of long-run economic growth, it is common to use historical or geographical variables as instruments for contemporary endogenous regressors. We study the interpretation of these conventional instrumental variable (IV) regressions in a general, yet simple, framework. Our aim...... quantitative implications for the field of long-run economic growth. We also use our framework to examine related empirical techniques. We find that two prominent regression methodologies - using gravity-based instruments for trade and including ancestry-adjusted variables in linear regression models - have...... is to estimate the long-run causal effect of changes in the endogenous explanatory variable. We find that conventional IV regressions generally cannot recover this parameter of interest. To estimate this parameter, therefore, we develop an augmented IV estimator that combines the conventional regression...

  2. Cell-Detection Technique for Automated Patch Clamping

    Science.gov (United States)

    McDowell, Mark; Gray, Elizabeth

    2008-01-01

    A unique and customizable machinevision and image-data-processing technique has been developed for use in automated identification of cells that are optimal for patch clamping. [Patch clamping (in which patch electrodes are pressed against cell membranes) is an electrophysiological technique widely applied for the study of ion channels, and of membrane proteins that regulate the flow of ions across the membranes. Patch clamping is used in many biological research fields such as neurobiology, pharmacology, and molecular biology.] While there exist several hardware techniques for automated patch clamping of cells, very few of those techniques incorporate machine vision for locating cells that are ideal subjects for patch clamping. In contrast, the present technique is embodied in a machine-vision algorithm that, in practical application, enables the user to identify good and bad cells for patch clamping in an image captured by a charge-coupled-device (CCD) camera attached to a microscope, within a processing time of one second. Hence, the present technique can save time, thereby increasing efficiency and reducing cost. The present technique involves the utilization of cell-feature metrics to accurately make decisions on the degree to which individual cells are "good" or "bad" candidates for patch clamping. These metrics include position coordinates (x,y) in the image plane, major-axis length, minor-axis length, area, elongation, roundness, smoothness, angle of orientation, and degree of inclusion in the field of view. The present technique does not require any special hardware beyond commercially available, off-the-shelf patch-clamping hardware: A standard patchclamping microscope system with an attached CCD camera, a personal computer with an imagedata- processing board, and some experience in utilizing imagedata- processing software are all that are needed. A cell image is first captured by the microscope CCD camera and image-data-processing board, then the image

  3. Utility of the three-dimensional reconstruction by means of helical scanography in the study of stringed instruments

    International Nuclear Information System (INIS)

    Morillo Zarate, Anibal Jose; Uriza Carrasco, Luis Felipe

    1998-01-01

    The evaluation of stringed instruments with axial computerized tomography (CT) sections has been described as a reliable method for the study of its internal components and for the detection of damaged instruments. We present the application of helical CT with thin sections and 3-D reconstructions in a series of violins, for an anatomical study of the instrument. The 3-D images offer complementary information and permit a better evaluation of the internal structure of the violin that can be useful for the understanding of the secrets of its construction and for the diagnosis of structural lesions that can affect its acoustic performance

  4. Portable (handheld) clinical device for quantitative spectroscopy of skin, utilizing spatial frequency domain reflectance techniques

    Science.gov (United States)

    Saager, Rolf B.; Dang, An N.; Huang, Samantha S.; Kelly, Kristen M.; Durkin, Anthony J.

    2017-09-01

    Spatial Frequency Domain Spectroscopy (SFDS) is a technique for quantifying in-vivo tissue optical properties. SFDS employs structured light patterns that are projected onto tissues using a spatial light modulator, such as a digital micromirror device. In combination with appropriate models of light propagation, this technique can be used to quantify tissue optical properties (absorption, μa, and scattering, μs', coefficients) and chromophore concentrations. Here we present a handheld implementation of an SFDS device that employs line (one dimensional) imaging. This instrument can measure 1088 spatial locations that span a 3 cm line as opposed to our original benchtop SFDS system that only collects a single 1 mm diameter spot. This imager, however, retains the spectral resolution (˜1 nm) and range (450-1000 nm) of our original benchtop SFDS device. In the context of homogeneous turbid media, we demonstrate that this new system matches the spectral response of our original system to within 1% across a typical range of spatial frequencies (0-0.35 mm-1). With the new form factor, the device has tremendously improved mobility and portability, allowing for greater ease of use in a clinical setting. A smaller size also enables access to different tissue locations, which increases the flexibility of the device. The design of this portable system not only enables SFDS to be used in clinical settings but also enables visualization of properties of layered tissues such as skin.

  5. Programming for a nuclear reactor instrument simulator

    International Nuclear Information System (INIS)

    Cohn, C.E.

    1989-01-01

    A new computerized control system for a transient test reactor incorporates a simulator for pre-operational testing of control programs. The part of the simulator pertinent to the discussion here consists of two microprocessors. An 8086/8087 reactor simulator calculates simulated reactor power by solving the reactor kinetics equations. An 8086 instrument simulator takes the most recent power value developed by the reactor simulator and simulates the appropriate reading on each of the eleven reactor instruments. Since the system is required to run on a one millisecond cycle, careful programming was required to take care of all eleven instruments in that short time. This note describes the special programming techniques used to attain the needed performance

  6. Assessing utility where short measures are required: development of the short Assessment of Quality of Life-8 (AQoL-8) instrument.

    Science.gov (United States)

    Hawthorne, Graeme

    2009-09-01

    As researchers seek to include clinical outcomes, the health-related quality of life (HRQoL) of participants and meet economic evaluation demands, they are confronted with collecting disparate outcome data where parsimony is imperative. This study addressed this through construction of a short HRQoL measure, the Assessment of Quality of Life (AQoL)-8 from the original AQoL. Data from the AQoL validation database (N = 996) were reanalyzed using item response theory (IRT) to identify the least fitting items, which were removed. The standard AQoL scoring algorithm and weights were applied. Validity, reliability, and sensitivity tests were carried out using the 2004 South Australian Health Omnibus Survey (N = 3015), including direct comparisons with other short utility measures, the EQ5D and SF6D. The IRT analysis showed that the AQoL was a weak scale (Loevinger H = 0.36) but reliable (Mokken rho = 0.84). Removal of the four weakest items led to an 8-item instrument with two items per subscale, the AQoL-8. The AQoL-8 Loevinger H = 0.38 and Mokken rho = 0.80 suggested similar psychometric properties to the AQoL. It correlated (intraclass correlation coefficient) 0.95 (or 90% of shared variance) with the AQoL. The AQoL-8 was as sensitive to six common health conditions as the AQoL, EQ5D, and SF6D. The utility scores fall on the same life-death scale as those of the AQoL. Where parsimony is imperative, researchers may consider use of the AQoL-8 to collect participant self-report HRQoL data that is suitable for use either as reported outcomes or for the calculation of quality-adjusted life-years for cost-utility analysis.

  7. On-line Monitoring and Calibration Techniques in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Hashemian, H.M.

    2011-01-01

    Years of research, testing and experience in the field of sensor diagnostics have yielded many technologies which offer financial as well as operational benefits to the nuclear industry. Among these technologies are On-Line Monitoring (OLM) and On-Line Calibration of critical process monitoring sensors such as resistance temperature detectors (RTD), thermocouples, and pressure transmitters to name a few. The remote access and verification of these sensors have been shown to limit the exposure of maintenance personnel to harsh environments while at the same time effectively and efficiently diagnosing the health and performance of these sensors. In addition to sensors, technologies exist in determining not only the health of instrumentation and control (I and C) cabling that carries the signals from these sensors, but also these same cable testing techniques can be used in the remote evaluation of many end devices used in safety related operations as well. Given these advances in sensor system monitoring techniques it would seem to follow that nuclear utilities from around the world would be applying these tried and true techniques to optimize up time and to provide additional confidence in the output of processing sensors. However, although several of the world's regulatory bodies have approved of the concept of these techniques, few utilities have undertaken to fully embrace on-line monitoring and on-line calibration of nuclear process sensors. In the United States efforts are now underway, with representatives of the U.S. nuclear industry and nuclear power plant vendors to obtain generic NRC licensing for the use of OLM in nuclear power plants. If approved, generic licensing will help pave the way toward greater implementation of OLM and its related calibration techniques. (author)

  8. A quantitative analysis of rotary, ultrasonic and manual techniques to treat proximally flattened root canals

    Directory of Open Access Journals (Sweden)

    Fabiana Soares Grecca

    2007-04-01

    Full Text Available OBJECTIVE: The efficiency of rotary, manual and ultrasonic root canal instrumentation techniques was investigated in proximally flattened root canals. MATERIAL AND METHODS: Forty human mandibular left and right central incisors, lateral incisors and premolars were used. The pulp tissue was removed and the root canals were filled with red die. Teeth were instrumented using three techniques: (i K3 and ProTaper rotary systems; (ii ultrasonic crown-down technique; and (iii progressive manual technique. Roots were bisected longitudinally in a buccolingual direction. The instrumented canal walls were digitally captured and the images obtained were analyzed using the Sigma Scan software. Canal walls were evaluated for total canal wall area versus non-instrumented area on which dye remained. RESULTS: No statistically significant difference was found between the instrumentation techniques studied (p<0.05. CONCLUSION: The findings of this study showed that no instrumentation technique was 100% efficient to remove the dye.

  9. Scintigraphic instruments and techniques in nuclear medicine

    International Nuclear Information System (INIS)

    Bornand, Bernard; Soussaline, Francoise; CEA, 91 - Orsay

    1978-01-01

    A short survey of data processing techniques in medical scintigraphy is presented. Three lists of abstracts being firstly from reviews, secondly from proceedings, and thirdly of reports and thesis, are presented as an addendum to the bibliography CEA-BIB-214, for the period 1975 up to march 1977. An index of authors and subjects is included. Finally an appendix with 18 patents is attached. Several bibliographical reviews: Excerpta Medica (Nuclear Medicine) Abstract Journal, INIS Atomindex, Nuclear Science Abstracts, together with a number of special journals and documents, recently published, have been used for this work [fr

  10. Development of infrared spectroscopy techniques for environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Sandsten, Jonas

    2000-08-01

    Infrared spectroscopy techniques have long been utilized in identifying and quantifying species of interest to us. Many of the elementary molecules in the atmosphere interact with infrared radiation through their ability to absorb and emit energy in vibrational and rotational transitions. A large variety of methods for monitoring of molecules and aerosol particles by collecting samples or by using remote sensing methods are available. The objective of the work presented in this thesis was to develop infrared spectroscopic techniques to further enhance the amount of useful information obtained from gathering spectral data. A new method for visualization and quantification of gas flows based on gas-correlation techniques was developed. Real-time imaging of gas leaks and incomplete or erratic flare combustion of ethene was demonstrated. The method relies on the thermal background as a radiation source and the gas can be visualized in absorption or in emission depending on the temperature difference. Diode laser spectroscopy was utilized to monitor three molecular species at the same time and over the same path. Two near-infrared diode lasers beams were combined in a periodically poled lithium niobate crystal and by difference-frequency generation a third beam was created, enabling simultaneous monitoring of oxygen, water vapor and methane. Models of aerosol particle cross sections were used to simulate the diffraction pattern of light scattered by fibers, spherical particles and real particles, such as pollen, through a new aerosol particle sensing prototype. The instrument, using a coupled cavity diode laser, has been designed with a ray-tracing program and the final prototype was employed for single aerosol particle sizing and identification.

  11. Low power data acquisition unit for autonomous geophysical instrumentation

    Science.gov (United States)

    Prystai, Andrii

    2017-04-01

    The development of an autonomous instrumentation for field research is always a challenge which needs knowledge and application of recent advances in technology and components production. Using this information a super-low power, low-cost, stand-alone GPS time synchronized data acquisition unit was created. It comprises an extended utilization of the microcontroller modules and peripherals and special firmware with flexible PLL parameters. The present report is devoted to a discussion of synchronization mode of data sampling in autonomous field instruments with possibility of GPS random breaks. In the result the achieved sampling timing accuracy is better than ± 60 ns without phase jumps and distortion plus fixed shift depending on the sample rate. The main application of the system is for simultaneous measurement of several channels from magnetic and electric sensors in field conditions for magneto-telluric instruments. First utilization of this system was in the new developed versions of LEMI-026 magnetometer and LEMI-423 field station, where it was applied for digitizing of up to 6 analogue channels with 32-bit resolution in the range ± 2.5V, digital filtration (LPF) and maximum sample rate 4kS/s. It is ready for record in 5 minutes after being turned on. Recently, this system was successfully utilized with the drone-portable magnetometers destined for the search of metallic objects, like UXO, in rural areas, research of engineering underground structure and for mapping ore bodies. The successful tests of drone-portable system were made and tests results are also discussed.

  12. Recent developments in nuclear instruments

    International Nuclear Information System (INIS)

    Vaidya, P.P.

    2004-01-01

    Full text : Nuclear Instrumentation is a field of vital importance for DAE. It has important applications in many areas of interest such as Reactor Monitoring and control, Accelerator based research, Laser and nuclear physics experiments, Health and environmental monitoring, Astrophysics experiments etc. It is a specialized field involving expertise in detection of radioactivity down to the level of few events per minute as well as processing and analysis of signals which can be as small as few hundred micro volts embedded in noise. Some applications involve digitizing and processing these signals with 0.001% accuracy and timing accuracies of a fraction of nano sec. Rapid developments in semiconductor related technologies have influenced the field of nuclear instrumentation. Development of FPGA's and ASIC's have made it possible to develop miniaturized smart and portable instruments for field applications. Advancements in field of computers, communications and various field buses have been successfully utilized for smart, portable and DSP based instrumentation. Smart sensor with detector and front-end electronics on a single silicon chip is now a reality. These instruments are also made intelligent by addition of fuzzy logic, artificial neural networks and expert systems. Electronics Division of BARC has made significant contribution to the field of nuclear instrumentation to achieve self-reliance in this area. This has also led to development of several new methods, which have been published in international journals and appreciated worldwide. As a step towards achieving complete self-reliance a programme for development of FPGA's, HMC's and ASIC's has been undertaken and is being followed with special emphasis. This also includes development of detector and front- end electronics on a single chip. This talk brings out details of these developments and describes the 'state of art' work done in India

  13. Comparison of two techniques for assessing the shaping efficacy of repeatedly used nickel-titanium rotary instruments.

    Science.gov (United States)

    Ounsi, Hani F; Franciosi, Giovanni; Paragliola, Raffaele; Al-Hezaimi, Khalid; Salameh, Ziad; Tay, Franklin R; Ferrari, Marco; Grandini, Simone

    2011-06-01

    The shaping capacity of nickel-titanium (NiTi) rotary instruments is often assessed by photographic or micro-computed tomography (micro-CT) measurements, and these instruments are often used more than once clinically. This study was conducted to compare photographic and micro-CT measurements and to assess if the repeated use of NiTi instruments affected the shape of canal preparation. Ten new sets of ProTaper Universal instruments (Dentsply-Maillefer, Ballaigues, Switzerland) were used in 60 resin blocks simulating curved root canals. Groups 1 to 6 (n=10) represented the first to sixth use of the instrument, respectively. Digitized images of the prepared blocks were taken in both mesiodistal (MD) and buccolingual (BL) directions and area measurements (mm(2)) were calculated using AutoCAD (Autodesk Inc, San Rafael, CA). The volumes of the same prepared canals were measured using micro-CT (mm(3)). Statistical analysis was performed to detect differences between photographic and volumetric measurements and differences between uses. Two-way repeated-measures analysis of variance revealed significant differences between groups (P < .001). Regarding measurement type, there were no significant differences between BL and MD measurements, but there were significant differences between micro-CT and BL measurements (P < .001) and micro-CT and MD measurements (P=.001). Significant differences were also noted between uses. Within the limitations of the present study, micro-CT scanning is more discriminative of the changes in canal space associated with repeated instrument use than photographic measurements. Canal preparations are significantly smaller after the third use of the same instrument. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  14. Cold Vacuum Drying Instrument Air System Design Description. System 12

    International Nuclear Information System (INIS)

    SHAPLEY, B.J.; TRAN, Y.S.

    2000-01-01

    This system design description (SDD) addresses the instrument air (IA) system of the spent nuclear fuel (SNF). This IA system provides instrument quality air to the Cold Vacuum Drying (CVD) Facility. The IA system is a general service system that supports the operation of the heating, ventilation, and air conditioning (HVAC) system, the process equipment skids, and process instruments in the CVD Facility. The following discussion is limited to the compressor, dryer, piping, and valving that provide the IA as shown in Drawings H-1-82222, Cold Vacuum Drying Facility Mechanical Utilities Compressed and Instrument Air PandID, and H-1.82161, Cold Vacuum Drying Facility Process Equipment Skid PandID MCO/Cusk Interface. Figure 1-1 shows the physical location of the 1A system in the CVD Facility

  15. Cold Vacuum Drying Instrument Air System Design Description (SYS 12)

    Energy Technology Data Exchange (ETDEWEB)

    SHAPLEY, B.J.; TRAN, Y.S.

    2000-06-05

    This system design description (SDD) addresses the instrument air (IA) system of the spent nuclear fuel (SNF). This IA system provides instrument quality air to the Cold Vacuum Drying (CVD) Facility. The IA system is a general service system that supports the operation of the heating, ventilation, and air conditioning (HVAC) system, the process equipment skids, and process instruments in the CVD Facility. The following discussion is limited to the compressor, dryer, piping, and valving that provide the IA as shown in Drawings H-1-82222, Cold Vacuum Drying Facility Mechanical Utilities Compressed & Instrument Air P&ID, and H-1.82161, Cold Vacuum Drying Facility Process Equipment Skid P&ID MCO/Cusk Interface. Figure 1-1 shows the physical location of the 1A system in the CVD Facility.

  16. Clinical utility of an endoscopic ultrasound-guided rendezvous technique via various approach routes.

    Science.gov (United States)

    Kawakubo, Kazumichi; Isayama, Hiroyuki; Sasahira, Naoki; Nakai, Yousuke; Kogure, Hirofumi; Hamada, Tsuyoshi; Miyabayashi, Koji; Mizuno, Suguru; Sasaki, Takashi; Ito, Yukiko; Yamamoto, Natsuyo; Hirano, Kenji; Tada, Minoru; Koike, Kazuhiko

    2013-09-01

    The endoscopic ultrasound-guided rendezvous techniques (EUS-rendezvous) provide reliable biliary access after failed endoscopic retrograde cholangiopancreatography (ERCP) cannulation. We evaluated the clinical utility of an EUS-rendezvous technique using various approach routes. Patients undergoing EUS-rendezvous for biliary access after failed bile duct cannulation in ERCP were included. EUS-rendezvous was performed via three approach routes depending on the patient's condition: transgastric, transduodenal in a short endoscopic position, or transduodenal in a long endoscopic position. The main outcomes were the technical success rates. Secondary outcomes were procedure time and complications. Fourteen patients (median age, 77 years) underwent EUS-rendezvous for biliary access resulting from failed biliary cannulation. The reasons for biliary drainage were malignant biliary obstruction in five patients and choledocholithiasis in nine. Transgastric, transduodenal in a short position, and transduodenal in a long position EUS-rendezvous was performed in five, five, and four patients, respectively. Bile duct puncture occurred in the left intrahepatic duct in four patients, right hepatic duct in one, middle common bile duct in four, and lower common bile duct in five. The technical success rate was 100 %. In four patients, the approach route was modified from transduodenal in a short position to transduodenal in a long position or transgastric route. The median procedure time was 81 min. One case each of biliary peritonitis and pancreatitis occurred and were managed conservatively. EUS-rendezvous provided safe and reliable transpapillary bile duct access after failed ERCP cannulation. The selection of the appropriate approach routes, depending on patient condition, is critical.

  17. Active instrumental guidance in interventional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Wildermuth, S.; Erhart, P.; Leung, D.A.; Goehde, S.; Schoenenberger, A.; Debatin, J.F.

    1998-01-01

    Purpose: An active MR-based guidance system for visualisation of invasive instruments is described. Methods: The principle of MR tracking is based on the integration of a miniaturised coil into the tip of the instrument itself. A phantom experiment was designed to demonstrate the localising accuracy of this technique. In [dition, bicompatibility and warming effects were evaluated. Preliminary intravascular applications that were performed in animal experiments under MR guidance included embolisation, vascular occlusion as well as transjugular intrahepatic punctures. Percutaneous biopsies, cholecystostomies and laparoscopic applications were also evaluated with MR tracking. Results: Phantom experiments confirmed an excellent localisation accuracy of MR tracking compared to conventional r[iography. At a field strength of 0.5 T, the temperature increase remained below 2 C. Results of phantom experiments revealed a potential of significant heating dependent on the sequence parameters employed. MR tracking allowed a robust, simultaneously biplanar visualisation of the instrument tips in real time. Based on MR 'ro[ map' images, various intravascular and percutaneous interventions were successfully performed in vivo under MR guidance. Conclusions: MR tracking is a flexible concept permitting monitoring in the guidance of instruments in an MR environment. Various preliminary in vitro and in vivo experiments demonstrate safety, localisation accuracy and feasibility of this biplanar localisation technique in real time. (orig.) [de

  18. Comparison of apical debris extrusion using a conventional and two rotary techniques.

    Science.gov (United States)

    Adl, Alireza; Sahebi, Safoora; Moazami, Fariborz; Niknam, Mahnaz

    2009-01-01

    Preparation techniques and instruments produce and push debris out of canals. This can induce inflammation within the periapical area. Therefore, instrumentation that causes less extrusion of debris is more desirable. The purpose of this in vitro study was to evaluate the quantity of debris extruded from the apical foramen during root canal preparation by using one hand, and two rotary instrumentation techniques. Three different groups each with 12 mesiobuccal roots of human maxillary first molar were instrumented using either step-back technique with hand instruments, FlexMaster or Mtwo rotary system. Debris extruded from the apical foramen during canal preparation was collected. The mean dry weights of debris were compared using one-way ANOVA. Step-back group had a significantly greater mean weight of debris compared to the other two groups (Pengine driven techniques were associated with less apical debris extrusion. [Iranian Endodontic Journal 2009;4(4):135-8].

  19. Instrumentation and signal processing for the detection of heavy water using off axis-integrated cavity output spectroscopy technique

    Science.gov (United States)

    Gupta, A.; Singh, P. J.; Gaikwad, D. Y.; Udupa, D. V.; Topkar, A.; Sahoo, N. K.

    2018-02-01

    An experimental setup is developed for the trace level detection of heavy water (HDO) using the off axis-integrated cavity output spectroscopy technique. The absorption spectrum of water samples is recorded in the spectral range of 7190.7 cm-1-7191.5 cm-1 with the diode laser as the light source. From the recorded water vapor absorption spectrum, the heavy water concentration is determined from the HDO and water line. The effect of cavity gain nonlinearity with per pass absorption is studied. The signal processing and data fitting procedure is devised to obtain linear calibration curves by including nonlinear cavity gain effects into the calculation. Initial calibration of mirror reflectivity is performed by measurements on the natural water sample. The signal processing and data fitting method has been validated by the measurement of the HDO concentration in water samples over a wide range from 20 ppm to 2280 ppm showing a linear calibration curve. The average measurement time is about 30 s. The experimental technique presented in this paper could be applied for the development of a portable instrument for the fast measurement of water isotopic composition in heavy water plants and for the detection of heavy water leak in pressurized heavy water reactors.

  20. Instrumental nuclear physics: elements for a proper choice

    International Nuclear Information System (INIS)

    1994-01-01

    This report consists of 11 documents about instrumental nuclear physics. It describes several detectors and data analysis techniques. Separate abstracts were prepared for all the papers in this volume. (TEC)

  1. The nuclear instrumentation system of the French 1400 MWe reactors

    International Nuclear Information System (INIS)

    Bourgerette, A.; Mauduit, J.P.

    1993-01-01

    The nuclear instrumentation systems in power reactors in France have made considerable advances thanks to technological progress. The appearance of an integrated digital protection system (SPIN) and the extension of digital techniques have considerably improved performance and operating flexibility. Working on the basis of technology developed jointly with the Nuclear Electronics and Instrumentation Department at the French Atomic Energy Commission (CEA), Framatome and Merlin Gerin have designed the new nuclear instrumentation system for 1400 MW reactors. (authors). 4 figs

  2. Appraisal of the Availability and Utilization of New Technological ...

    African Journals Online (AJOL)

    FIRST LADY

    Items 31 - 36 ... instrument was a 36-item questionnaire developed by the researchers. The ... Nigeria utilize new technological resources in science curriculum delivery. ... science instructions makes learning of science concepts clearer to.

  3. Instrumentation for PSD based neutron diffractometers at Dhruva reactor

    International Nuclear Information System (INIS)

    Pande, S.S.; Borkar, S.P.; Prafulla, S.; Srivastava, V.D.; Behare, A.; Mukhopadhyay, P.K.; Ghodgaonkar, M.D.; Kataria, S.K.

    2004-01-01

    Linear position sensitive detectors (PSDs) are widely used to configure neutron diffractometers and other instruments. Necessary front-end electronics and a data acquisition system is developed to cater to such instruments built around the Dhruva research reactor in BARC. These include three diffractometers with multiple PSDs and four with single PSD. The front-end electronics consists of high voltage units, preamplifiers, shaping amplifiers, ratio ADCs (RDC). The data acquisition system consists of an interface card and software. Commercially available hardware like temperature controller or stepper motor controller connected over GPIB or RS232 are also integrated in the data acquisition system. The data acquisition is automated so that it can continue unattended for control parameter like temperature, thus enabling optimum utilization of available beam time. The instrumentation is scalable and can be easily configured for various instrumental requirements. The front-end electronics and the data acquisition system are described here. (author)

  4. Dosimetry tools and techniques for IMRT

    International Nuclear Information System (INIS)

    Low, Daniel A.; Moran, Jean M.; Dempsey, James F.; Dong Lei; Oldham, Mark

    2011-01-01

    Intensity modulated radiation therapy (IMRT) poses a number of challenges for properly measuring commissioning data and quality assurance (QA) radiation dose distributions. This report provides a comprehensive overview of how dosimeters, phantoms, and dose distribution analysis techniques should be used to support the commissioning and quality assurance requirements of an IMRT program. The proper applications of each dosimeter are described along with the limitations of each system. Point detectors, arrays, film, and electronic portal imagers are discussed with respect to their proper use, along with potential applications of 3D dosimetry. Regardless of the IMRT technique utilized, some situations require the use of multiple detectors for the acquisition of accurate commissioning data. The overall goal of this task group report is to provide a document that aids the physicist in the proper selection and use of the dosimetry tools available for IMRT QA and to provide a resource for physicists that describes dosimetry measurement techniques for purposes of IMRT commissioning and measurement-based characterization or verification of IMRT treatment plans. This report is not intended to provide a comprehensive review of commissioning and QA procedures for IMRT. Instead, this report focuses on the aspects of metrology, particularly the practical aspects of measurements that are unique to IMRT. The metrology of IMRT concerns the application of measurement instruments and their suitability, calibration, and quality control of measurements. Each of the dosimetry measurement tools has limitations that need to be considered when incorporating them into a commissioning process or a comprehensive QA program. For example, routine quality assurance procedures require the use of robust field dosimetry systems. These often exhibit limitations with respect to spatial resolution or energy response and need to themselves be commissioned against more established dosimeters. A chain of

  5. Present status of research on radiation utilization in 1994 at JAERI. Utilization of irradiation and RI production and utilization

    International Nuclear Information System (INIS)

    1994-10-01

    In Japan Atomic Energy Research Institute, Takasaki Radiation Chemistry Research Establishment is in charge of the utilization of irradiation, and Tokai Research Establishment is in charge of the production and utilization of radioisotopes. As for the utilization of irradiation the development of new polymers, the development of environment preservation technology such as flue gas treatment, and by using various ion beams from four accelerators, the development of the materials used for space environment, nuclear fusion and new functional materials, the research on the radiation application to biotechnology, the development of the production and utilization of new radioisotopes have been carried out. As for the production and utilization of radioisotopes, the development of new products and new utilization techniques, the technology of producing and using a large amount of tritium, and the research on the chemical behavior of tritium have been carried out. The international cooperations have been promoted positively. In this report, the research activities in 1994 are described. (K.I.)

  6. New instruments for radiation protection

    International Nuclear Information System (INIS)

    Bartos, D.; Ciobanu, M.; Constantin, F.; Petcu, M.; Plostinaru, V.D.; Rusu, Al.; Lupu, A.C.; Lupu, F.

    2003-01-01

    Though a century old, the radiation protection is actual by its purpose: a dose as low as reasonable achievable is to be received either by involved professionals or population. This threshold is dependent on the technical progress. Some major developments like surface mounted device technology, consumer almost ideal operational amplifiers, microcontrollers and the news signal digital processing techniques, offer the opportunity to design improved instruments for radioprotection. To put in a light portable instrument both the whole measuring system and the 'intelligence' - a microcontroller and the associated software - are the main ideas applied by the authors. The result is presented: a family of eight members, at least, based on two parents. (authors)

  7. Validation of smart sensor technologies for instrument calibration reduction in nuclear power plants

    International Nuclear Information System (INIS)

    Hashemian, H.M.; Mitchell, D.W.; Petersen, K.M.; Shell, C.S.

    1993-01-01

    This report presents the preliminary results of a research and development project on the validation of new techniques for on-line testing of calibration drift of process instrumentation channels in nuclear power plants. These techniques generally involve a computer-based data acquisition and data analysis system to trend the output of a large number of instrument channels and identify the channels that have drifted out of tolerance. This helps limit the calibration effort to those channels which need the calibration, as opposed to the current nuclear industry practice of calibrating essentially all the safety-related instrument channels at every refueling outage

  8. Efforts onto electricity and instrumentation technology for nuclear power generation

    International Nuclear Information System (INIS)

    Hayakawa, Toshifumi

    2000-01-01

    Nuclear power generation shares more than 1/3 of all amounts of in-land generation at present, as a supplying source of stable electric energy after 2000 either. As a recent example of efforts onto electricity and instrumentation technology for nuclear power generation, there are, on instrumentation control system a new central control board aiming at reduction of operator's load, protection of human error, and upgrading of system reliability and economics by applying high level micro-processor applied technique and high speed data transfer technique to central monitoring operation and plant control protection, on a field of reactor instrumentation a new digital control rod position indicator improved of conventional system on a base of operation experience and recent technology, on a field of radiation instrumentation a new radiation instrumentation system accumulating actual results in a wide application field on a concept of application to nuclear power plant by adopting in-situ separation processing system using local network technique, and on a field of operation maintenance and management a conservation management system for nuclear generation plant intending of further effectiveness of operation maintenance management of power plant by applying of operation experience and recent data processing and communication technology. And, in the large electric apparatus, there are some generators carried out production and verification of a model one with actual size in lengthwise dimension, to correspond to future large capacity nuclear power plant. By this verification, it was proved that even large capacity generator of 1800 MVA class could be manufactured. (G.K.)

  9. Developing a Research Instrument to Document Awareness, Knowledge, and Attitudes Regarding Breast Cancer and Early Detection Techniques for Pakistani Women: The Breast Cancer Inventory (BCI

    Directory of Open Access Journals (Sweden)

    Atta Abbas Naqvi

    2016-12-01

    Full Text Available There is a general hesitation in participation among Pakistani women when it comes to giving their responses in surveys related to breast cancer which may be due to the associated stigma and conservatism in society. We felt that no research instrument was able to extract information from the respondents to the extent it was needed for the successful execution of our study. The need to develop a research instrument tailored for Pakistani women was based upon the fact that most Pakistani women come from a conservative background and sometimes view this topic as provocative and believe discussing publicly about it as inappropriate. Existing research instruments exhibited a number of weaknesses during literature review. Therefore, using them may not be able to extract information concretely. A research instrument was, thus, developed exclusively. It was coined as, “breast cancer inventory (BCI” by a panel of experts for executing a study aimed at documenting awareness, knowledge, and attitudes of Pakistani women regarding breast cancer and early detection techniques. The study is still in the data collection phase. The statistical analysis involved the Kaiser-Meyer-Olkin (KMO measure and Bartlett’s test for sampling adequacy. In addition, reliability analysis and exploratory factor analysis (EFA were, also employed. This concept paper focuses on the development, piloting and validation of the BCI. It is the first research instrument which has high acceptability among Pakistani women and is able to extract adequate information from the respondents without causing embarrassment or unease.

  10. Scientific instruments, scientific progress and the cyclotron

    International Nuclear Information System (INIS)

    Baird, David; Faust, Thomas

    1990-01-01

    Philosophers speak of science in terms of theory and experiment, yet when they speak of the progress of scientific knowledge they speak in terms of theory alone. In this article it is claimed that scientific knowledge consists of, among other things, scientific instruments and instrumental techniques and not simply of some kind of justified beliefs. It is argued that one aspect of scientific progress can be characterized relatively straightforwardly - the accumulation of new scientific instruments. The development of the cyclotron is taken to illustrate this point. Eight different activities which promoted the successful completion of the cyclotron are recognised. The importance is in the machine rather than the experiments which could be run on it and the focus is on how the cyclotron came into being, not how it was subsequently used. The completed instrument is seen as a useful unit of scientific progress in its own right. (UK)

  11. Intelligent data-acquisition instrumentation for special nuclear material assay data analysis

    International Nuclear Information System (INIS)

    Ethridge, C.D.

    1980-01-01

    The Detection, Surveillance, Verification, and Recovery Group of the Los Alamos Scientific Laboratory Energy Division/Nuclear Safeguards Programs is now utilizing intelligent data-acquisition instrumentation for assay data analysis of special nuclear material. The data acquisition and analysis are enabled by the incorporation of a number-crunching microprocessor sequenced by a single component microcomputer. Microcomputer firmware establishes the capability for processing the computation of several selected functions and also the ability of instrumentation self-diagnostics

  12. Application of non-destructive impedance-based monitoring technique for cyclic fatigue evaluation of endodontic nickel-titanium rotary instruments.

    Science.gov (United States)

    Chang, Yau-Zen; Liu, Mou-Chuan; Pai, Che-An; Lin, Chun-Li; Yen, Kuang-I

    2011-06-01

    This study investigates the application of non-destructive testing based on the impedance theory in the cyclic fatigue evaluation of endodontic Ni-Ti rotary instruments. Fifty Ni-Ti ProTaper instruments were divided into five groups (n=10 in Groups A to E). Groups A to D were subjected to cyclic fatigue within an artificial canal (Group E was the control group). The mean value of the total life limit (TLL), defined as the instrument being rotated until fracture occurred was found to be 104 s in Group A. Each rotary instrument in Groups B, C and D were rotated until the tested instruments reached 80% (84 s), 60% (62 s) and 40% (42 s) of the TLL. After fatigue testing, each rotary instrument was mounted onto a custom-developed non-destructive testing device to give the tip of the instrument a progressive sideways bend in four mutually perpendicular directions to measure the corresponding impedance value (including the resistance and the reactance). The results indicated that the impedance value showed the same trend as the resistance, implying that the impedance was primarily affected by the resistance. The impedance value for the instruments in the 80% and 60% TLL groups increased by about 6 mΩ (about 7.5%) more than that of the instruments in the intact and 40% TLL groups. The SEM analysis result showed that crack striations were only found at the tip of the thread on the cracked surface of the instrument, consistent with the impedance measurements that found the impedance value of the cracked surface to be significantly different from those in other surfaces. These findings indicate that the impedance value may represent an effective parameter for evaluating the micro-structural status of Ni-Ti rotary instruments subjected to fatigue loading. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. Payment Instrument Characteristics

    DEFF Research Database (Denmark)

    Holst, Jacques; Kjeldsen, Martin; Hedman, Jonas

    2015-01-01

    Over the last decade, we have witnessed payment innovations that fundamentally have changed the ways we pay. Payment innovations, such as mobile payments and on-line banking, include characteristics or features that are essential to understand if we want to know how and why payers choose among...... payment innovations. Using the Repertory Grid technique to explore 15 payers’ perception of six payment instruments, including coins, banknotes, debit cards, credit cards, mobile payments, and on-line banking, we identify 16 payment characteristics. The characteristics aggregate seventy-six unique...

  14. Neutrons and music: Imaging investigation of ancient wind musical instruments

    Energy Technology Data Exchange (ETDEWEB)

    Festa, G., E-mail: giulia.festa@roma2.infn.it [Università degli Studi di Roma Tor Vergata (Italy); Università degli Studi di Milano-Bicocca (Italy); Consiglio Nazionale delle Ricerche-IPCF, Messina (Italy); Tardino, G. [BauArt Basel, Basel (Switzerland); Pontecorvo, L. [Conservatorio di Cosenza – Cosenza Conservatory (Italy); Mannes, D.C. [Paul Scherrer Institut, Villigen (Switzerland); Senesi, R. [Università degli Studi di Roma Tor Vergata (Italy); Consiglio Nazionale delle Ricerche-IPCF, Messina (Italy); Gorini, G. [Università degli Studi di Milano-Bicocca (Italy); Andreani, C. [Università degli Studi di Roma Tor Vergata (Italy); Consiglio Nazionale delle Ricerche-IPCF, Messina (Italy)

    2014-10-01

    A set of seven musical instruments and two instruments cares from the ‘Fondo Antico della Biblioteca del Sacro Convento’ in Assisi, Italy, were investigated through neutron and X-ray imaging techniques. Historical and scientific interests around ancient musical instruments motivate an intense research effort for their characterization using non-destructive and non-invasive techniques. X-ray and neutron tomography/radiography were applied to the study of composite material samples containing wood, hide and metals. The study was carried out at the NEUTRA beamline, PSI (Paul Scherrer Institute, Switzerland). Results of the measurements provided new information on the composite and multi-scale structure, such as: the internal structure of the samples, position of added materials like metals, wood fiber displays, deformations, presence of adhesives and their spatial distribution and novel insight about construction methods to guide the instruments’ restoration process.

  15. Neutrons and music: Imaging investigation of ancient wind musical instruments

    International Nuclear Information System (INIS)

    Festa, G.; Tardino, G.; Pontecorvo, L.; Mannes, D.C.; Senesi, R.; Gorini, G.; Andreani, C.

    2014-01-01

    A set of seven musical instruments and two instruments cares from the ‘Fondo Antico della Biblioteca del Sacro Convento’ in Assisi, Italy, were investigated through neutron and X-ray imaging techniques. Historical and scientific interests around ancient musical instruments motivate an intense research effort for their characterization using non-destructive and non-invasive techniques. X-ray and neutron tomography/radiography were applied to the study of composite material samples containing wood, hide and metals. The study was carried out at the NEUTRA beamline, PSI (Paul Scherrer Institute, Switzerland). Results of the measurements provided new information on the composite and multi-scale structure, such as: the internal structure of the samples, position of added materials like metals, wood fiber displays, deformations, presence of adhesives and their spatial distribution and novel insight about construction methods to guide the instruments’ restoration process

  16. Computational and instrumental methods in EPR

    CERN Document Server

    Bender, Christopher J

    2006-01-01

    Computational and Instrumental Methods in EPR Prof. Bender, Fordham University Prof. Lawrence J. Berliner, University of Denver Electron magnetic resonance has been greatly facilitated by the introduction of advances in instrumentation and better computational tools, such as the increasingly widespread use of the density matrix formalism. This volume is devoted to both instrumentation and computation aspects of EPR, while addressing applications such as spin relaxation time measurements, the measurement of hyperfine interaction parameters, and the recovery of Mn(II) spin Hamiltonian parameters via spectral simulation. Key features: Microwave Amplitude Modulation Technique to Measure Spin-Lattice (T1) and Spin-Spin (T2) Relaxation Times Improvement in the Measurement of Spin-Lattice Relaxation Time in Electron Paramagnetic Resonance Quantitative Measurement of Magnetic Hyperfine Parameters and the Physical Organic Chemistry of Supramolecular Systems New Methods of Simulation of Mn(II) EPR Spectra: Single Cryst...

  17. Design and installation of advanced computer safety related instrumentation

    International Nuclear Information System (INIS)

    Koch, S.; Andolina, K.; Ruether, J.

    1993-01-01

    The rapidly developing area of computer systems creates new opportunities for commercial utilities operating nuclear reactors to improve plant operation and efficiency. Two of the main obstacles to utilizing the new technology in safety-related applications is the current policy of the licensing agencies and the fear of decision making managers to introduce new technologies. Once these obstacles are overcome, advanced diagnostic systems, CRT-based displays, and advanced communication channels can improve plant operation considerably. The article discusses outstanding issues in the area of designing, qualifying, and licensing of computer-based instrumentation and control systems. The authors describe the experience gained in designing three safety-related systems, that include a Programmable Logic Controller (PLC) based Safeguard Load Sequencer for NSP Prairie Island, a digital Containment Isolation monitoring system for TVA Browns Ferry, and a study that was conducted for EPRI/NSP regarding a PLC-based Reactor Protection system. This article presents the benefits to be gained in replacing existing, outdated equipment with new advanced instrumentation

  18. When are network coding based dynamic multi-homing techniques beneficial?

    DEFF Research Database (Denmark)

    Pereira, Carlos; Aguiar, Ana; Roetter, Daniel Enrique Lucani

    2016-01-01

    Mechanisms that can cope with unreliable wireless channels in an efficient manner are required due to the increasing number of resource constrained devices. Concurrent use of multiple communications technologies can be instrumental towards improving services to mobile devices in heterogeneous...... networks. In our previous work, we developed an optimization framework to generate channel-aware transmission policies for multi-homed devices under different cost criteria. Our formulation considers network coding as a key technique that simplifies load allocation across multiple channels and provides...... high resiliency under time-varying channel conditions. This paper seeks to explore the parameter space and identify the operating regions where dynamic coded policies offer most improvement over static ones in terms of energy consumption and channel utilization. We leverage meta-heuristics to find...

  19. Fabrication of Non-instrumented capsule for DUPIC simulated fuel irradiation test in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B.G.; Kang, Y.H.; Park, S.J.; Shin, Y.T. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-10-01

    In order to develope DUPIC nuclear fuel, the irradiation test for simulated DUPIC fuel was planed using a non-instrumented capsule in HANARO. Because DUPIC fuel is highly radioactive material the non-instrumented capsule for an irradiation test of simulated DUPIC fuel in HANARO was designed to remotely assemble and disassemble in hot cell. And then, according to the design requirements the non-instrumented DUPIC capsule was successfully manufactured. Also, the manufacturing technologies of the non-instrumented capsule for irradiating the nuclear fuel in HANARO were established, and the basic technology for the development of the instrumented capsule technology was accumulated. This report describes the manufacturing of the non-instrumented capsule for simulated DUPIC fuel. And, this report will be based to develope the instrumented capsule, which will be utilized to irradiate the nuclear fuel in HANARO. 26 refs., 4 figs. (Author)

  20. Development of the Electron Drift Instrument (EDI) for Cluster

    Science.gov (United States)

    Quinn, Jack; Christensen, John L. (Technical Monitor)

    2001-01-01

    The Electron Drift Instrument (EDI) is a new technique for measuring electric fields in space by detecting the effect on weak beams of test electrons. This U.S. portions of the technique, flight hardware, and flight software were developed for the Cluster mission under this contract. Dr. Goetz Paschmann of the Max Planck Institute in Garching, Germany, was the Principle Investigator for Cluster EDI. Hardware for Cluster was developed in the U.S. at the University of New Hampshire, Lockheed Palo Alto Research Laboratory, and University of California, San Diego. The Cluster satellites carrying the original EDI instruments were lost in the catastrophic launch failure of first flight of the Arianne-V rocket in 1996. Following that loss, NASA and ESA approved a rebuild of the Cluster mission, for which all four satellites were successfully launched in the Summer of 2000. Limited operations of EDI were also obtained on the Equator-S satellite, which was launched in December, 1997. A satellite failure caused a loss of the Equator-S mission after only 5 months, but these operations were extremely valuable in learning about the characteristics and operations of the complex EDI instrument. The Cluster mission, satellites, and instruments underwent an extensive on-orbit commissioning phase in the Fall of 2000, carrying over through January 2001. During this period all elements of the instruments were checked and careful measurements of inter-experiments interferences were made. EDI is currently working exceptionally well in orbit. Initial results verify that all aspects of the instrument are working as planned, and returning highly valuable scientific information. The first two papers describing EDI on-orbit results have been submitted for publication in April, 2001. The principles of the EDI technique, and its implementation on Cluster are described in two papers by Paschmann et al., attached as Appendices A and B. The EDI presentation at the formal Cluster Commissioning

  1. Instrument to determine prestress remaining in a damaged bridge girder

    Science.gov (United States)

    Civjan, Scott A.; Jirsa, James O.; Carrasquillo, Ramon L.; Fowler, David W.

    1998-03-01

    An instrument has been developed to estimate stress levels in prestress strands in existing members. The prototype instrument applies a lateral load to an exposed prestressing strand and measures the resulting displacements. The instrument was calibrated for 0.5-inch (12.7 mm) diameter seven-wire strand with exposed lengths of 1.5 feet (0.46 m) to 3.75 feet (1.14 m). It was tested to determine its accuracy, precision, and usefulness in the field. Strand forces were consistently estimated to within ten percent of the actual load. The device was also utilized in the placement of strand splices and was found to be more reliable in checking induced strand tensions than the standard torque wrench method.

  2. Statistical comparisons of Savannah River anemometer data applied to quality control of instrument networks

    International Nuclear Information System (INIS)

    Porch, W.M.; Dickerson, M.H.

    1976-08-01

    Continuous monitoring of extensive meteorological instrument arrays is a requirement in the study of important mesoscale atmospheric phenomena. The phenomena include pollution transport prediction from continuous area sources, or one time releases of toxic materials and wind energy prospecting in areas of topographic enhancement of the wind. Quality control techniques that can be applied to these data to determine if the instruments are operating within their prescribed tolerances were investigated. Savannah River Plant data were analyzed with both independent and comparative statistical techniques. The independent techniques calculate the mean, standard deviation, moments about the mean, kurtosis, skewness, probability density distribution, cumulative probability and power spectra. The comparative techniques include covariance, cross-spectral analysis and two dimensional probability density. At present the calculating and plotting routines for these statistical techniques do not reside in a single code so it is difficult to ascribe independent memory size and computation time accurately. However, given the flexibility of a data system which includes simple and fast running statistics at the instrument end of the data network (ASF) and more sophisticated techniques at the computational end (ACF) a proper balance will be attained. These techniques are described in detail and preliminary results are presented

  3. Translating state-of-the-art spinal cord MRI techniques to clinical use: A systematic review of clinical studies utilizing DTI, MT, MWF, MRS, and fMRI.

    Science.gov (United States)

    Martin, Allan R; Aleksanderek, Izabela; Cohen-Adad, Julien; Tarmohamed, Zenovia; Tetreault, Lindsay; Smith, Nathaniel; Cadotte, David W; Crawley, Adrian; Ginsberg, Howard; Mikulis, David J; Fehlings, Michael G

    2016-01-01

    A recent meeting of international imaging experts sponsored by the International Spinal Research Trust (ISRT) and the Wings for Life Foundation identified 5 state-of-the-art MRI techniques with potential to transform the field of spinal cord imaging by elucidating elements of the microstructure and function: diffusion tensor imaging (DTI), magnetization transfer (MT), myelin water fraction (MWF), MR spectroscopy (MRS), and functional MRI (fMRI). However, the progress toward clinical translation of these techniques has not been established. A systematic review of the English literature was conducted using MEDLINE, MEDLINE-in-Progress, Embase, and Cochrane databases to identify all human studies that investigated utility, in terms of diagnosis, correlation with disability, and prediction of outcomes, of these promising techniques in pathologies affecting the spinal cord. Data regarding study design, subject characteristics, MRI methods, clinical measures of impairment, and analysis techniques were extracted and tabulated to identify trends and commonalities. The studies were assessed for risk of bias, and the overall quality of evidence was assessed for each specific finding using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework. A total of 6597 unique citations were identified in the database search, and after full-text review of 274 articles, a total of 104 relevant studies were identified for final inclusion (97% from the initial database search). Among these, 69 studies utilized DTI and 25 used MT, with both techniques showing an increased number of publications in recent years. The review also identified 1 MWF study, 11 MRS studies, and 8 fMRI studies. Most of the studies were exploratory in nature, lacking a priori hypotheses and showing a high (72%) or moderately high (20%) risk of bias, due to issues with study design, acquisition techniques, and analysis methods. The acquisitions for each technique varied widely across

  4. Optical Methods and Instrumentation in Brain Imaging and Therapy

    CERN Document Server

    2013-01-01

    This book provides a comprehensive up-to-date review of optical approaches used in brain imaging and therapy. It covers a variety of imaging techniques including diffuse optical imaging, laser speckle imaging, photoacoustic imaging and optical coherence tomography. A number of laser-based therapeutic approaches are reviewed, including photodynamic therapy, fluorescence guided resection and photothermal therapy. Fundamental principles and instrumentation are discussed for each imaging and therapeutic technique. Represents the first publication dedicated solely to optical diagnostics and therapeutics in the brain Provides a comprehensive review of the principles of each imaging/therapeutic modality Reviews the latest advances in instrumentation for optical diagnostics in the brain Discusses new optical-based therapeutic approaches for brain diseases

  5. Current trends in pedicle screw stimulation techniques: lumbosacral, thoracic, and cervical levels.

    Science.gov (United States)

    Isley, Michael R; Zhang, Xiao-Feng; Balzer, Jeffrey R; Leppanen, Ronald E

    2012-06-01

    justification" of intraoperative neuromonitoring"... is the perception that the safety and efficacy of pedicle screw fixation are enhanced..." (Resnick et al. 2005b). However in summarizing a massive (over 1000 papers taken from the National Library of Medicine), contemporary, literature review spanning nearly a decade (1996 to 2003), this invited panel (Resnick et al. 2005b) recognized that the evidence-based documents contributing to the parts related to pedicle screw fixation and neuromonitoring were "... full of potential sources of error ..." and lacked appropriate, randomized, prospective studies for formulating rigid standards and guidelines. Nevertheless, current trends support the routine use and clinical utility of these neuromonitoring techniques. In particular free-run and triggered EMG have been well recognized in numerous publications for improving both the accuracy and safety of pedicle screw implantation. Currently, treatment with pedicle screw instrumentation routinely involves all levels of the spine - lumbosacral, thoracic, and cervical. Significant historical events, various neuromonitoring modalities, intraoperative alarm criteria, clinical efficacy, current trends, and caveats related to pedicle screw stimulation along the entire vertebral column will be reviewed.

  6. Instrumentation for PSD-based neutron diffractometers at Dhruva reactor

    Science.gov (United States)

    Pande, S. S.; Borkar, S. P.; Prafulla, S.; Srivastava, V. D.; Behare, A.; Mukhopadhyay, P. K.; Ghodgaonkar, M. D.; Kataria, S. K.

    2004-08-01

    Linear position sensitive detectors (PSDs) are widely used to configure neutron diffractometers and other instruments. Necessary front-end electronics and a data acquisition system [1] is developed to cater to such instruments built around the Dhruva research reactor in BARC. These include three diffractometers with multiple PSDs and four with single PSD. The front-end electronics consists of high voltage units, preamplifiers [2], shaping amplifiers, ratio ADCs (RDC) [3]. The data acquisition system consists of an interface card and software. Commercially available hardware like temperature controller or stepper motor controller connected over GPIB or RS232 are also integrated in the data acquisition system. The data acquisition is automated so that it can continue unattended for control parameter like temperature, thus enabling optimum utilization of available beam time. The instrumentation is scalable and can be easily configured for various instrumental requirements. The front-end electronics and the data acquisition system are described here.

  7. Utility application of simulation software

    International Nuclear Information System (INIS)

    Sudduth, A.L.

    1986-01-01

    The purpose of this paper is to discuss dynamic system simulation from the perspective of a successful utility user. In it, four aspects of the issue of utility use of simulation will be addressed: (1) What simulation software is available to utilities which can be of practical assistance with a modest investment in staff and training. (2) To what specific problems can utilities apply the technique of simulation and achieve reasonably cost effective results. (3) What the advantages are of in-house dynamic simulation capability, as opposed to depending on NSSS vendors or consultants. (4) What the prospects are for wider use of dynamic simulation in the utility industry

  8. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    Energy Technology Data Exchange (ETDEWEB)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides. (JGB)

  9. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    International Nuclear Information System (INIS)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides

  10. Corrosion protection of reusable surgical instruments.

    Science.gov (United States)

    Shah, Sadiq; Bernardo, Mildred

    2002-01-01

    To understand the corrosion properties of surgical scissors, 416 stainless steel disks and custom electrodes were used as simulated surfaces under various conditions. These simulated surfaces were exposed to tap water and 400-ppm synthetic hard water as Ca2CO3 under different conditions. The samples were evaluated by various techniques for corrosion potential and the impact of environmental conditions on the integrity of the passive film. The electrodes were used to monitor the corrosion behavior by potentiodynamic polarization technique in water both in the presence and absence of a cleaning product. The surface topography of the 416 stainless steel disks was characterized by visual observations and scanning electron microscopy (SEM), and the surface chemistry of the passive film on the surface of the scissors was characterized by x-ray photoelectron spectroscopy (XPS). The results suggest that surgical instruments made from 416 stainless steel are not susceptible to uniform corrosion; however, they do undergo localized corrosion. The use of suitable cleaning products can offer protection against localized corrosion during the cleaning step. More importantly, the use of potentiodynamic polarization techniques allowed for a quick and convenient approach to evaluate the corrosion properties of surgical instruments under a variety of simulated-use environmental conditions.

  11. Integrating photovoltaics into utility distribution systems

    International Nuclear Information System (INIS)

    Zaininger, H.W.; Barnes, P.R.

    1995-01-01

    Electric utility distribution system impacts associated with the integration of distributed photovoltaic (PV) energy sources vary from site to site and utility to utility. The objective of this paper is to examine several utility- and site-specific conditions which may affect economic viability of distributed PV applications to utility systems. Assessment methodology compatible with technical and economic assessment techniques employed by utility engineers and planners is employed to determine PV benefits for seven different utility systems. The seven case studies are performed using utility system characteristics and assumptions obtained from appropriate utility personnel. The resulting site-specific distributed PV benefits increase nonsite-specific generation system benefits available to central station PV plants as much as 46%, for one utility located in the Southwest

  12. Varying ultrasound power level to distinguish surgical instruments and tissue.

    Science.gov (United States)

    Ren, Hongliang; Anuraj, Banani; Dupont, Pierre E

    2018-03-01

    We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of varying transducer power level images. The proposed framework exploits the physics of ultrasound imaging system by varying the transducer power level to effectively distinguish metallic surgical instruments from tissue. This power-varying image-guidance is motivated from our observations that ultrasound imaging at different power levels exhibit different contrast enhancement capabilities between tissue and instruments in ultrasound-guided robotic beating-heart surgery. Using lower transducer power levels (ranging from 40 to 75% of the rated lowest ultrasound power levels of the two tested ultrasound scanners) can effectively suppress the strong imaging artifacts from metallic instruments and thus, can be utilized together with the images from normal transducer power levels to enhance the separability between instrument and tissue, improving intraoperative instrument tracking accuracy from the acquired noisy ultrasound volumetric images. We performed experiments in phantoms and ex vivo hearts in water tank environments. The proposed multi-level power-varying ultrasound imaging approach can identify robotic instruments of high acoustic impedance from low-signal-to-noise-ratio ultrasound images by power adjustments.

  13. Review of techniques and detectors used in instruments for field measurement of beta doses and dose rates

    International Nuclear Information System (INIS)

    Jones, A.R.

    1983-01-01

    Generally, field measurements are required to assess the hazard from #betta#-rays before personnel are allowed to occupy a working space or perform a task. Occasionally, the measurements are required for an assessment after a #betta#-ray exposure is suspected to have occurred. Until recently the dose or dose rate have been the quantities of interest but there is now felt to be a need to characterize the energies and directions of the #betta#-rays as well. The purpose of #betta#-dosimetry is the assessment of hazard to superficial tissues (within approx. 10 mm of the surface) and that these tissues may also be exposed simultaneously to other ionizing radiations. The #betta#-dosimetry technique must take account of this. With these uses of field instruments in mind the following detectors, and associated techniques will be discussed in terms of the measurement principles, advantages and limitations: thin-walled ion chambers (sometimes in combination with thick-walled ones or with covers thick enough to prevent penetration of #betta#-particles); thin scintillators, nearly tissue equivalent, to provide a detector analogous to skin; scintillators, thick enough to absorb all the energy of the #betta#-particles (circuitry is required to count pulses according to size to permit calculation of dose or dose rate); silicon diodes with thin detection layers operated as photocurrent generators; silicon diodes, reversed biassed, with pulses counted according to size; and simple pulse counters (e.g., GM counters or silicon diodes with thin windows)

  14. Effectiveness of an educational video as an instrument to refresh and reinforce the learning of a nursing technique: a randomized controlled trial.

    Science.gov (United States)

    Salina, Loris; Ruffinengo, Carlo; Garrino, Lorenza; Massariello, Patrizia; Charrier, Lorena; Martin, Barbara; Favale, Maria Santina; Dimonte, Valerio

    2012-05-01

    The Undergraduate Nursing Course has been using videos for the past year or so. Videos are used for many different purposes such as during lessons, nurse refresher courses, reinforcement, and sharing and comparison of knowledge with the professional and scientific community. The purpose of this study was to estimate the efficacy of the video (moving an uncooperative patient from the supine to the lateral position) as an instrument to refresh and reinforce nursing techniques. A two-arm randomized controlled trial (RCT) design was chosen: both groups attended lessons in the classroom as well as in the laboratory; a month later while one group received written information as a refresher, the other group watched the video. Both groups were evaluated in a blinded fashion. A total of 223 students agreed to take part in the study. The difference observed between those who had seen the video and those who had read up on the technique turned out to be an average of 6.19 points in favour of the first (P video were better able to apply the technique, resulting in a better performance. The video, therefore, represents an important tool to refresh and reinforce previous learning.

  15. INSTRUMENTATION FOR ENVIRONMENTAL MONITORING--Radiation--Vol3Pt1

    Energy Technology Data Exchange (ETDEWEB)

    Authors, Various

    1972-01-02

    A comprehensive survey of instrumentation for environmental monitoring is being carried out by the Lawrence Berkeley Laboratory originally under a grant from the National Science Foundation and now by the Office of Health and Environmental Research of the Department of Energy. Instruments being investigated are those useful for measurements in Air Quality, Water Quality, Radiation, and Biomedicine related to environmental research and monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to this work. The results of the survey are given as (a) descriptions of the physical and operating characteristics of available instruments, (b) critical comparisons among instrumentation methods, and (c) recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored: their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls.

  16. Overview: Field instrumentation - A Mikado's dream

    International Nuclear Information System (INIS)

    Spittler, T.M.

    1992-01-01

    The Mikado of Gilbert ampersand Sullivan fame held out as an open-quotes object all sublimeclose quotes which he hoped to open-quotes achieve in timeclose quotes the fitting of the punishment to the crime. Like that potentate, I too have long held the hope of finding instrumentation which is ideally suited to measurement of environmental contaminants in the field. Today, at least one of us has had that dream fulfilled. For years, those of us interested in field analysis have had to apply time consuming and cumbersome methods to relatively simple and often short-term environmental measurement problems. Meanwhile, we watched the literature and perused the product blurbs in hopes of finding the ideal tools for on-site, real time analysis. Of course, that search will always go forward as better instruments are developed. Today we can finally point to many pieces of equipment that are on the market and which provide high quality data in real time for a number of the most important environmental contaminants. Furthermore, the sensitivity of some of these field instruments exceeds that of conventional lab instrumentation. Coupled with innovative techniques for sample preparation and proper quality control, field instrumentation can often go a long way to solving problems in rapid detection, quantitation, and positive identification

  17. Standardization of portable assay instrumentation: the neutron-coincidence tree

    International Nuclear Information System (INIS)

    Menlove, H.O.

    1983-01-01

    Standardization of portable neutron assay instrumentation has been achieved by using the neutron coincidence technique as a common basis for a wide range of instruments and applications. The electronics originally developed for the High-Level Neutron Coincidence Counter has been adapted to both passive- and active-assay instrumentation for field verification of bulk plutonium, inventory samples, pellets, powders, nitrates, high-enriched uranium, and materials-testing-reactor, light-water-reactor, and mixed-oxide fuel assemblies. The family of detectors developed at Los Alamos National Laboratory and their performance under in-field conditions are described. 16 figures, 3 tables

  18. Instrumental tactile diagnostics in robot-assisted surgery

    Directory of Open Access Journals (Sweden)

    Solodova RF

    2016-10-01

    Full Text Available Rozalia F Solodova,1,2 Vladimir V Galatenko,1,2 Eldar R Nakashidze,3 Igor L Andreytsev,3 Alexey V Galatenko,1 Dmitriy K Senchik,2 Vladimir M Staroverov,1 Vladimir E Podolskii,1,2 Mikhail E Sokolov,1,2 Victor A Sadovnichy1,2 1Faculty of Mechanics and Mathematics, 2Institute of Mathematical Studies of Complex Systems, Lomonosov Moscow State University, 31st Surgery Department, Clinical Hospital 31, Moscow, Russia Background: Robotic surgery has gained wide acceptance due to minimizing trauma in patients. However, the lack of tactile feedback is an essential limiting factor for the further expansion. In robotic surgery, feedback related to touch is currently kinesthetic, and it is mainly aimed at the minimization of force applied to tissues and organs. Design and implementation of diagnostic tactile feedback is still an open problem. We hypothesized that a sufficient tactile feedback in robot-assisted surgery can be provided by utilization of Medical Tactile Endosurgical Complex (MTEC, which is a novel specialized tool that is already commercially available in the Russian Federation. MTEC allows registration of tactile images by a mechanoreceptor, real-time visualization of these images, and reproduction of images via a tactile display. Materials and methods: Nine elective surgeries were performed with da Vinci™ robotic system. An assistant performed tactile examination through an additional port under the guidance of a surgeon during revision of tissues. The operating surgeon sensed registered tactile data using a tactile display, and the assistant inspected the visualization of tactile data. First, surgeries where lesion boundaries were visually detectable were performed. The goal was to promote cooperation between the surgeon and the assistant and to train them in perception of the tactile feedback. Then, instrumental tactile diagnostics was utilized in case of visually undetectable boundaries. Results: In robot-assisted surgeries where lesion

  19. Safari: instrument design of the far-infrared imaging spectrometer for spica

    Science.gov (United States)

    Jellema, W.; Pastor, C.; Naylor, D.; Jackson, B.; Sibthorpe, B.; Roelfsema, P.

    2017-11-01

    The next great leap forward in space-based far-infrared astronomy will be made by the Japanese-led SPICA mission, which is anticipated to be launched late 2020's as the next large astrophysics mission of JAXA, in partnership with ESA and with key European contributions. Filling in the gap between JWST and ALMA, the SPICA mission will study the evolution of galaxies, stars and planetary systems. SPICA will utilize a deeply cooled 3m-class telescope, provided by European industry, to realize zodiacal background limited performance, high spatial resolution and large collecting area. Making full advantage of the deeply cooled telescope (architecture. We will describe the reference design of the SAFARI focal- plane unit, the implementation of the various optical instrument functions designed around the central large-stroke FTS system, the photometric band definition and out-of-band filtering by quasioptical elements, the control of straylight, diffraction and thermal emission in the long-wavelength limit, and how we interface to the large-format FPA arrays at one end and the SPICA telescope assembly at the other end. We will briefly discuss the key performance drivers with special emphasis on the optical techniques adopted to overcome issues related to very low background operation of SAFARI. A summary and discussion of the expected instrument performance and an overview of the astronomical capabilities finally conclude the paper.

  20. FFTF utilization for irradiation testing

    International Nuclear Information System (INIS)

    Corrigan, D.C.; Julyk, L.J.; Hoth, C.W.; McGuire, J.C.; Sloan, W.R.

    1980-01-01

    FFTF utilization for irradiation testing is beginning. Two Fuels Open Test Assemblies and one Vibration Open Test Assembly, both containing in-core contact instrumentation, are installed in the reactor. These assemblies will be used to confirm plant design performance predictions. Some 100 additional experiments are currently planned to follow these three. This will result in an average core loading of about 50 test assemblies throughout the early FFTF operating cycles

  1. Positron emission tomography: Physics, instrumentation, and image analysis

    International Nuclear Information System (INIS)

    Porenta, G.

    1994-01-01

    Positron emission tomography (PET) is a noninvasive diagnostic technique that permits reconstruction of cross-sectional images of the human body which depict the biodistribution of PET tracer substances. A large variety of physiological PET tracers, mostly based on isotopes of carbon, nitrogen, oxygen, and fluorine is available and allows the in vivo investigation of organ perfusion, metabolic pathways and biomolecular processes in normal and diseased states. PET cameras utilize the physical characteristics of positron decay to derive quantitative measurements of tracer concentrations, a capability that has so far been elusive for conventional SPECT (single photon emission computed tomography) imaging techniques. Due to the short half lives of most PET isotopes, an on-site cyclotron and a radiochemistry unit are necessary to provide an adequate supply of PET tracers. While operating a PET center in the past was a complex procedure restricted to few academic centers with ample resources. PET technology has rapidly advanced in recent years and has entered the commercial nuclear medicine market. To date, the availability of compact cyclotrons with remote computer control, automated synthesis units for PET radiochemistry, high-performance PET cameras, and userfriendly analysis workstations permits installation of a clinical PET center within most nuclear medicine facilities. This review provides simple descriptions of important aspects concerning physics, instrumentation, and image analysis in PET imaging which should be understood by medical personnel involved in the clinical operation of a PET imaging center. (author)

  2. Corrosion rate of steel in concrete - Evaluation of confinement techniques for on-site corrosion rate

    DEFF Research Database (Denmark)

    Nygaard, Peter Vagn; Geiker, Mette Rica; Elsener, Bernhard

    2009-01-01

    Earlier on-site investigations and laboratory studies have shown that varying corrosion rates are obtained when different commercially available instruments are used. The different confinement techniques, rather than the different electrochemical techniques used in the instruments, are considered...... to be the main reason for the discrepancies. This paper presents a method for the quantitative assessment of confinement techniques based on monitoring the operation of the corrosion rate instrument and the current distribution between the electrode assembly on the concrete surface and a segmented reinforcement...... bar embedded in the concrete. The applicability of the method was demonstrated on two commercially available corrosion rate instruments based on different confinement techniques. The method provided an explanation of the differences in performance of the two instruments. Correlated measurements...

  3. [The utility of the interrupter technique in pediatric asthma].

    Science.gov (United States)

    Iimura, Akiko; Yoshihara, Shigemi; Arisaka, Osamu

    2002-11-01

    Interrupter respiratory resistance (Rint) is a new lung function test for measuring airway resistance. We investigated the utility of the Rint lung function test in pediatric patients with asthma. Thirty seven asthmatic patients with mild or moderate asthma attack (asthma group) and 9 healthy children (control group) were enrolled in the study, and the utility of the Ring test was compared with that of the PEF lung function test. Rint and PEF were measured after the inhalation of saline or beta(2) stimulant, and the values for the asthma and control groups were compared. The rint and PEF values did not change after the inhalation of saline, but both values improved after the inhalation of beta(2) stimulant in the asthma group. In the control group, the PEF and Rint values measured after saline or beta(2) stimulant were not significantly different. Rint measurements may be more useful than PEF tests for evaluating therapeutic responses to mild asthma attacks in children. These findings suggest that Rint is a useful respiratory function test for evaluating children with asthma.

  4. Exploratory and Creative Properties of Physical-Modeling-based Musical Instruments

    DEFF Research Database (Denmark)

    Gelineck, Steven

    Digital musical instruments are developed to enable musicians to find new ways of expressing themselves. The development and evaluation of these instruments can be approached from many different perspectives depending on which capabilities one wants the musicians to have. This thesis attempts...... to approach development and evaluation of these instruments with the notion that instruments today are able to facilitate the creative process that is so crucial for creating music. The fundamental question pursued throughout the thesis is how creative work processes of composers of electronic music can...... be supported and even challenged by the instruments they use. What is it that makes one musical instrument more creatively inspiring than another, and how do we evaluate how well it succeeds? In order to present answers to these questions, the thesis focusses on the sound synthesis technique of physical...

  5. The utilization of cranial models created using rapid prototyping techniques in the development of models for navigation training.

    Science.gov (United States)

    Waran, V; Pancharatnam, Devaraj; Thambinayagam, Hari Chandran; Raman, Rajagopal; Rathinam, Alwin Kumar; Balakrishnan, Yuwaraj Kumar; Tung, Tan Su; Rahman, Z A

    2014-01-01

    Navigation in neurosurgery has expanded rapidly; however, suitable models to train end users to use the myriad software and hardware that come with these systems are lacking. Utilizing three-dimensional (3D) industrial rapid prototyping processes, we have been able to create models using actual computed tomography (CT) data from patients with pathology and use these models to simulate a variety of commonly performed neurosurgical procedures with navigation systems. To assess the possibility of utilizing models created from CT scan dataset obtained from patients with cranial pathology to simulate common neurosurgical procedures using navigation systems. Three patients with pathology were selected (hydrocephalus, right frontal cortical lesion, and midline clival meningioma). CT scan data following an image-guidance surgery protocol in DIACOM format and a Rapid Prototyping Machine were taken to create the necessary printed model with the corresponding pathology embedded. The ability in registration, planning, and navigation of two navigation systems using a variety of software and hardware provided by these platforms was assessed. We were able to register all models accurately using both navigation systems and perform the necessary simulations as planned. Models with pathology utilizing 3D rapid prototyping techniques accurately reflect data of actual patients and can be used in the simulation of neurosurgical operations using navigation systems. Georg Thieme Verlag KG Stuttgart · New York.

  6. Utilization of mining and mineral wastes

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Ho; Hong, Seung Woong; Choi, Young Yoon; Kim, Byung Gyu; Park, Je Shin [Korea Institute of Geology Mining and Materials, Taejon (Korea)

    1998-12-01

    Up to now, it is estimated that more than 50 million tons of mineral wastes have been generated mining industries and deposited on the land in Korea. Much of cultivated land and hilly areas have been occupied by this wastes, which cause pollution of the environment. Utilization of the mineral wastes is preferable to stabilization because full use would both eliminate the waste and broaden the mineral resource base. Therefore, the development of utilization techniques of mineral wastes is very important not only for improving the environment but also for resource conservation. In countries with high population and poor natural resources like Korea, the utilization of these wastes is essential to decrease the environmental problem and the secure the resources and the study on this field play a important part. Therefore, the objective of this study is to develop the utilization techniques of the mineral wastes. In first year's research, the contents and scope of this study are 1) Present condition and Field Survey on the mineral wastes with respect of their utilization, 2) Reviews of Current effects and research to utilize mineral wastes, 3) Characterization of mineral wastes and environmental test, 4) Evaluation and study on the utilization. (author). 67 refs., 25 tabs., 54 figs.

  7. Utilization of mining and mineral wastes

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Ho; Hong, Seung Woong; Choi, Young Yoon; Kim, Byung Gyu; Park, Je Shin [Korea Institute of Geology Mining and Materials, Taejon (Korea)

    1998-12-01

    Up to now, it is estimated that more than 50 million tons of mineral wastes have been generated mining industries and deposited on the land in Korea. Much of cultivated land and hilly areas have been occupied by this wastes, which cause pollution of the environment. Utilization of the mineral wastes is preferable to stabilization because full use would both eliminate the waste and broaden the mineral resource base. Therefore, the development of utilization techniques of mineral wastes is very important not only for improving the environment but also for resource conservation. In countries with high population and poor natural resources like Korea, the utilization of these wastes is essential to decrease the environmental problem and the secure the resources and the study on this field play a important part. Therefore, the objective of this study is to develop the utilization techniques of the mineral wastes. In first year's research, the contents and scope of this study are 1) Present condition and Field Survey on the mineral wastes with respect of their utilization, 2) Reviews of Current effects and research to utilize mineral wastes, 3) Characterization of mineral wastes and environmental test, 4) Evaluation and study on the utilization. (author). 67 refs., 25 tabs., 54 figs.

  8. Long range radio tracking of sea turtles and polar bear: Instrumentation and preliminary results

    Science.gov (United States)

    Baldwin, H. A.

    1972-01-01

    Instrumentation developed for studies of path behavior of the green sea turtle and migration movement of polar bear is described. Preliminary results bearing on navigation ability in these species are presented. Both species operate in difficult environments, and the problems faced in the design of electronic instrumentation for these studies are not completely specified at this time. However, the critical factors yet to be understood are primarily related to the behavior of instrumented animals. The data obtained with these experimental techniques are included, first to illustrate the technique and, second to provide initial preliminary results bearing on animal navigation.

  9. A systematic literature review of health state utility values in head and neck cancer.

    Science.gov (United States)

    Meregaglia, Michela; Cairns, John

    2017-09-02

    Health state utility values (HSUVs) are essential parameters in model-based economic evaluations. This study systematically identifies HSUVs in head and neck cancer and provides guidance for selecting them from a growing body of health-related quality of life studies. We systematically reviewed the published literature by searching PubMed, EMBASE and The Cochrane Library using a pre-defined combination of keywords. The Tufts Cost-Effectiveness Analysis Registry and the School of Health and Related Research Health Utilities Database (ScHARRHUD) specifically containing health utilities were also queried, in addition to the Health Economics Research Centre database of mapping studies. Studies were considered for inclusion if reporting original HSUVs assessed using established techniques. The characteristics of each study including country, design, sample size, cancer subsite addressed and demographics of responders were summarized narratively using a data extraction form. Quality scoring and critical appraisal of the included studies were performed based on published recommendations. Of a total 1048 records identified by the search, 28 studies qualified for data extraction and 346 unique HSUVs were retrieved from them. HSUVs were estimated using direct methods (e.g. standard gamble; n = 10 studies), multi-attribute utility instruments (MAUIs; n = 13) and mapping techniques (n = 3); two studies adopted both direct and indirect approaches. Within the MAUIs, the EuroQol 5-dimension questionnaire (EQ-5D) was the most frequently used (n = 11), followed by the Health Utility Index Mark 3 (HUI3; n = 2), the 15D (n = 2) and the Short Form-Six Dimension (SF-6D; n = 1). Different methods and types of responders (i.e. patients, healthy subjects, clinical experts) influenced the magnitude of HSUVs for comparable health states. Only one mapping study developed an original algorithm using head and neck cancer data. The identified studies were considered

  10. UTILIZING CREEKS FOR INTEGRATED RURAL COASTAL ...

    African Journals Online (AJOL)

    Osondu

    2013-02-09

    Feb 9, 2013 ... This study examines the Utilization of Creeks for Integrated Coastal Development of Ilaje ... utilization, poor fishing techniques, poor sources of water and navigation routes, and manual ... Ethiopian Journal of Environmental Studies and Management Vol. 6 No.3 .... together, implement, monitor and evaluate.

  11. Reduction in bacterial counts in infected root canals after rotary or hand nickel-titanium instrumentation--a clinical study.

    Science.gov (United States)

    Rôças, I N; Lima, K C; Siqueira, J F

    2013-07-01

    To compare the antibacterial efficacy of two instrumentation techniques, one using hand nickel-titanium (NiTi) instruments and the other using rotary NiTi instruments, in root canals of teeth with apical periodontitis. Root canals from single-rooted teeth were instrumented using either hand NiTi instruments in the alternated rotation motion technique or rotary BioRaCe instruments. The irrigant used in both groups was 2.5% NaOCl. DNA extracts from samples taken before and after instrumentation were subjected to quantitative analysis by real-time polymerase chain reaction (qPCR). Qualitative analysis was also performed using presence/absence data from culture and qPCR assays. Bacteria were detected in all S1 samples by both methods. In culture analysis, 45% and 35% of the canals were still positive for bacterial presence after hand and rotary NiTi instrumentation, respectively (P > 0.05). Rotary NiTi instrumentation resulted in significantly fewer qPCR-positive cases (60%) than hand NiTi instrumentation (95%) (P = 0.01). Intergroup comparison of quantitative data showed no significant difference between the two techniques. There was no significant difference in bacterial reduction in infected canals after instrumentation using hand or rotary NiTi instruments. In terms of incidence of positive results for bacteria, culture also showed no significant differences between the groups, but the rotary NiTi instrumentation resulted in more negative results in the more sensitive qPCR analysis. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  12. Student mathematical imagination instruments: construction, cultural adaptation and validity

    Science.gov (United States)

    Dwijayanti, I.; Budayasa, I. K.; Siswono, T. Y. E.

    2018-03-01

    Imagination has an important role as the center of sensorimotor activity of the students. The purpose of this research is to construct the instrument of students’ mathematical imagination in understanding concept of algebraic expression. The researcher performs validity using questionnaire and test technique and data analysis using descriptive method. Stages performed include: 1) the construction of the embodiment of the imagination; 2) determine the learning style questionnaire; 3) construct instruments; 4) translate to Indonesian as well as adaptation of learning style questionnaire content to student culture; 5) perform content validation. The results stated that the constructed instrument is valid by content validation and empirical validation so that it can be used with revisions. Content validation involves Indonesian linguists, english linguists and mathematics material experts. Empirical validation is done through a legibility test (10 students) and shows that in general the language used can be understood. In addition, a questionnaire test (86 students) was analyzed using a biserial point correlation technique resulting in 16 valid items with a reliability test using KR 20 with medium reability criteria. While the test instrument test (32 students) to find all items are valid and reliability test using KR 21 with reability is 0,62.

  13. Utilizing the GentleWave® System for Debridement of Undetected Apical Anatomy.

    Science.gov (United States)

    Ford, Michael W

    2018-03-01

    Debriding and disinfecting complex anatomies within the root canal system pose a major challenge during root canal therapy. Even with current chemomechanical techniques, debris and bacterial remnants are commonly left behind, which are generally believed to increase the risk of endodontic failure. This case details the use of a new technique to debride complex apical anatomy in a maxillary molar. A 48-year-old female presented to the clinic with a chief complaint of increasing pain in her tooth. Clinical examination of the right first maxillary molar (#3) revealed moderate sensitivity to percussion and mild sensitivity to palpation. A pulpal diagnosis of symptomatic irreversible pulpitis and a periapi-cal diagnosis of symptomatic apical periodontitis were made. Mechanical instrumentation was performed using rotary file size #25/.04 for the mesiobuccal and distobuccal canals and size #25/.06 for the palatal canal to create a fluid path and enable obturation of the root canal system following the GentleWave® Procedure. The GentleWave Procedure was completed using Multisonic Ultracleaning™ for complete debridement and disinfection of the root canal system. The tooth was obturated using a warm vertical continuous wave obturation technique. Postoperative radiographs revealed complex anatomy within the apical third that was undetected both during pre-operative radiography and mechanical instrumentation. The palatal canal exhibited a complex apical delta with multiple points of exit, and the mesiobuccal canal revealed an undetected lateral canal within the apical third that had a separate and distinct egress. Conclusion and clinical significance: It is important for the clinician to debride and disinfect complex anatomy within the root canal system to reduce the risk of endodontic failure. This case report highlights the clinical significance of utilizing the GentleWave Procedure for detecting complex apical anatomy during endodontic therapy.

  14. TECHNICAL TRAINING SEMINAR: National Instruments

    CERN Multimedia

    Monique Duval

    2004-01-01

    From 9:30 to 12:00 and from 13:00 to 16:00 hrs - Council Chamber, Salle B, Salle des Pas Perdus National Instruments (NI) on Tour 2004 Claudia Jüngel, Evrem Yarkin, Joel Clerc, Hervé Baour / NATIONAL INSTRUMENTS The special event NI on Tour 2004, run in Germany, Austria and Switzerland, will be at CERN on March 30. Technical seminars and free introductory courses will be offered all day long in the Council Chamber, Salle B, and Salle des Pas Perdus (buildings 61 and 503). Data acquisition systems on PCs, industrial measurement and control techniques, advanced LabVIEW software and PXI instrumentation, and system components for tests and automation will be presented. Walk-in courses will address DIAdem, LabVIEW and data acquisition. Language: English and French Free seminars and courses, no registration Organisers: Rolf Stampfli / IT-CO / 78102 & 160367 / Rolf.Stampfli@cern.ch Davide Vitè / HR-PMD-ATT / 75141 Davide.Vite@cern.ch For more information and the complete event programme, please visit the...

  15. Nuclear techniques in industry

    International Nuclear Information System (INIS)

    Hammad, F.H.

    1994-01-01

    Nuclear techniques are utilized in almost every industry. The discussion in this paper includes discussions on tracer methods and uses nucleonic control systems technology; non-destructive testing techniques and radiation technology. 1 fig., 2 tabs

  16. In vitro comparative study of manual and mechanical rotary instrumentation of root canals using computed tomography.

    Science.gov (United States)

    Limongi, Orlando; de Albuquerque, Diana Santana; Baratto Filho, Flares; Vanni, José Roberto; de Oliveira, Elias P Motcy; Barletta, Fernando Branco

    2007-01-01

    This in vitro study compared, using computed tomography (CT), the amount of dentin removed from root canal walls by manual and mechanical rotary instrumentation techniques. Forty mandibular incisors with dental crown and a single canal were selected. The teeth were randomly assigned to two groups, according to the technique used for root canal preparation: Group I - manual instrumentation with stainless steel files; Group II - mechanical instrumentation with RaCe rotary nickel-titanium instruments. In each tooth, root dentin thickness of the buccal, lingual, mesial and distal surfaces in the apical, middle and cervical thirds of the canal was measured (in mm) using a multislice CT scanner (Siemens Emotion, Duo). Data were stored in the SPSS v. 11.5 and SigmaPlot 2001 v. 7.101 softwares. After crown opening, working length was determined, root canals were instrumented and new CT scans were taken for assessment of root dentin thickness. Pre- and post-instrumentation data were compared and analyzed statistically by ANOVA and Tukey's post-hoc test for significant differences (p=0.05). Based on the findings of this study, it may be concluded that regarding dentin removal from root canal walls during instrumentation, neither of the techniques can be considered more effective than the other.

  17. PERFORMANCE CONFIRMATION IN-SITU INSTRUMENTATION

    International Nuclear Information System (INIS)

    N.T. Raczka

    2000-01-01

    The purpose of this document is to identify and analyze the types of in-situ instruments and methods that could be used in support of the data acquisition portion of the Performance Confirmation (PC) program at the potential nuclear waste repository at Yucca Mountain. The PC program will require geomechanical , geophysical, thermal, and hydrologic instrumentation of several kinds. This analysis is being prepared to document the technical issues associated with each type of measurement during the PC period. This analysis utilizes the ''Performance Confirmation Input Criteria'' (CRWMS M andO 1999a) as its starting point. The scope of this analysis is primarily on the period after the start of waste package emplacement and before permanent closure of the repository, a period lasting between 15 and 300 years after last package emplacement (Stroupe 2000, Attachment 1, p. 1). The primary objectives of this analysis are to: (1) Review the design criteria as presented in the ''Performance Confirmation Input Criteria'' (CRWMS M andO 1999a). The scope of this analysis will be limited to the instrumentation related to parameters that require continuous monitoring of the conditions underground. (2) Preliminary identification and listing of the data requirements and parameters as related to the current repository layout in support of PC monitoring. (3) Preliminary identification of methods and instrumentation for the acquisition of the required data. Although the ''Performance Confirmation Input Criteria'' (CRWMS M andO 1999a) defines a broad range of data that must be obtained from a variety of methods, the focus of this analysis is on instrumentation related to the performance of the rock mass and the formation of water in the repository environment, that is obtainable from in-situ observation, testing, and monitoring

  18. Real-time instrument-failure detection in the LOFT pressurizer using functional redundancy

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1982-07-01

    The functional redundancy approach to detecting instrument failures in a pressurized water reactor (PWR) pressurizer is described and evaluated. This real-time method uses a bank of Kalman filters (one for each instrument) to generate optimal estimates of the pressurizer state. By performing consistency checks between the output of each filter, failed instruments can be identified. Simulation results and actual pressurizer data are used to demonstrate the capabilities of the technique

  19. How EPRI [Electric Power Research Institute] helps utilities save money

    International Nuclear Information System (INIS)

    Anon.

    1996-01-01

    A number of case studies are presented which illustrate how the work of the Electric Power Research Institute in the USA has enabled nuclear utilities to save money. The areas covered by the examples are: steam generator tube repair; streamlining of reliability centred maintenance; cost effective instrumentation and control maintenance; reducing the frequency of instrument calibration; optimising the engineering change process; detecting and reducing fuel failure; extending the qualified life of equipment. (U.K.)

  20. Heterodyne quasi-elastic light-scattering instrument for biomedical diagnostics.

    Science.gov (United States)

    Lebedev, A D; Ivanova, M A; Lomakin, A V; Noskin, V A

    1997-10-20

    The heterodyne technique has a number of advantages over the homodyne technique when an accurate characterization of particle-size distribution (PSD) of heterogeneous systems is required. However, there are problems related to acoustic vibrations that make it difficult to take advantage of the heterodyne technique. An instrument developed for quasi-elastic light scattering (QELS) that uses the optical heterodyning principle is described. Vibration-related problems are considerably reduced because of the incorporation of all optical elements into one solid optical block. A real-time correlation analysis of the photocurrent fluctuations is performed by a PC-embedded analog-to-digital converter card with a digital signal processor. Investigation of the PSD in biological fluids for medical diagnostics is presented as a typical application. A diagnostic analysis of the PSD requires a simultaneous processing of a huge number of QELS data. An original statistical algorithm to accomplish this analysis has been developed. Technical specifications of instrumentation for heterodyne QELS measurement are discussed.

  1. Enhanced Measurements of Chromophoric Dissolved Organic Matter (CDOM) for Water Quality Analysis using a New Simultaneous Absorbance and Fluorescence Instrument

    Science.gov (United States)

    Gilmore, A. M.

    2009-12-01

    Water quality, with respect to suspended particles and dissolved organic and inorganic compounds, is now recognized as one of the top global environmental concerns. Contemporary research indicates fluorescence spectral analyses coupled with UV-VIS absorbance assays have the potential, especially when combined and coordinated, to facilitate rapid, robust quantification of a wide range of compounds, including interactions among them. Fluorescence excitation-emission matrices (EEMs) collected over the UV-VIS region provide a wealth of information on chromophoric dissolved organic matter (CDOM). CDOM includes humic and fulvic acid, chlorophyll, petroleum, protein, amino acid, quinone, fertilizer, pesticide, sewage and numerous other compound classes. Analysis of the EEMs using conventional and multivariate techniques, including primarily parallel factor analysis (PARAFAC), provides information about many types of CDOM relevant to carbon cycling and pollution of fresh, marine and drinking water sources. Of critical concern also are the CDOM interactions with, and optical activities of, dissolved inorganic compounds. Many of the inorganic compounds and oxygen demand parameters can be analyzed with a wide range of UV-VIS absorbance assays. The instrument is designed and optimized for high UV throughput and low stray light performance. The sampling optics are optimized for both fluorescence and absorbance detection with the same sample. Both EEM and absorbance measurements implement NIST traceable instrument correction and calibration routines. The fluorescence detection utilizes a high dynamic range CCD coupled to a high-resolution spectrograph while absorbance utilizes diode based detection with a high dynamic range and extremely low-stray light specifications. The CDOM analysis is facilitated by a transfer of the data and model information with the PARAFAC routine. The EEM analysis software package facilitates coordinated correction of and correlation with the

  2. Comparison of the Effect of Canal Preparation by Step Back Technique Using Hand Instruments and Gates Glidden Drills with ProTaper Universal Rotary System on the Root Resistance to Vertical Fracture

    OpenAIRE

    A Abbaszadegan; Z Sadat Aleyasin; M Sedigh Shamsi; Sh Shahriari

    2013-01-01

    Introduction: Cleaning and shaping of the root canal system with an efficient and safe technique are the major goals of root canal treatment. The aim of this study was to compare the conventional root canal preparation technique by hand instruments and Gates Glidden drills with ProTaper Universal Rotary system on the root susceptibility to vertical fracture. Methods: Thirty extracted human mandibular premolars were randomly assigned to two groups. In group I, apical preparation was performed ...

  3. Obtaining the neutron time-of-flight instrument response function for a single D-T neutron utilizing n-alpha coincidence from the d(t, α) n nuclear reaction

    Science.gov (United States)

    Styron, Jedediah; Ruiz, Carlos; Hahn, Kelly; Cooper, Gary; Chandler, Gordon; Jones, Brent; McWatters, Bruce; Smith, Jenny; Vaughan, Jeremy

    2017-10-01

    A measured neutron time-of-flight (nTOF) signal is a convolution of the neutron reaction history and the instrument response function (IRF). For this work, the IRF was obtained by measuring single, D-T neutron events by utilizing n-alpha coincidence. The d(t, α) n nuclear reaction was produced at Sandia National Laboratories' Ion Beam Laboratory using a 300-keV Cockroft-Walton generator to accelerate a 2- μA beam, of 175-keV D + ions, into a stationary, 2.6- μm, ErT2 target. Comparison of these results to those obtained using cosmic-rays and photons will be discussed. Sandia National Laboratories.

  4. Absorption coefficient instrument for turbid natural waters

    Science.gov (United States)

    Friedman, E.; Cherdak, A.; Poole, L.; Houghton, W.

    1980-01-01

    The paper presents an instrument that directly measures multispectral absorption coefficient of turbid natural water. Attention is given to the design, which is shown to incorporate methods for the compensation of variation in the internal light source intensity, correction of the spectrally dependent nature of the optical elements, and correction for variation in the background light level. In addition, when used in conjunction with a spectrally matched total attenuation instrument, the spectrally dependent scattering coefficient can also be derived. Finally, it is reported that systematic errors associated with multiple scattering have been estimated using Monte Carlo techniques.

  5. An in vitro comparison of apically extruded debris using three rotary nickel-titanium instruments

    Directory of Open Access Journals (Sweden)

    Tamer Tasdemir

    2010-09-01

    Conclusion: According to this study, all instrumentation techniques apically extruded debris through the apical foramen. However, the BioRaCe instruments induced less extruded debris than the ProTaper Universal and Mtwo rotary systems.

  6. Instrumentation for two-phase flow measurements in code verification experiments

    International Nuclear Information System (INIS)

    Fincke, J.R.; Anderson, J.L.; Arave, A.E.; Deason, V.A.; Lassahn, G.D.; Goodrich, L.D.; Colson, J.B.; Fickas, E.T.

    1981-01-01

    The development of instrumentation and techniques for the measurement of mass flow rate in two-phase flows conducted at the Idaho National Engineering Laboratory during the past year is briefly described. Instruments discussed are the modular drag-disc turbine transducer, the gamma densitometers, the ultrasonic densitometer, Pitot tubes, and full-flow drag screens. Steady state air-water and transient steam-water data are presented

  7. Current status of operation, utilization and refurbishment of the Dalat nuclear research reactor

    International Nuclear Information System (INIS)

    Pham Duy Hien.

    1993-01-01

    The reconstructed nuclear research reactor at Dalat, Vietnam has been put into operation since March 1984. Up to present a cumulative operation time of 13,172 hrs at nominal power (500 kW) has been recorded. Production of radioisotopes for medical uses, element analysis by using activation techniques, as well as fundamental and applied research with filtered neutrons are the main activities of reactor utilizations. The problems facing Dalat Nuclear Research Institute are the ageing of the re-used TRIGA-MARK-II reactor components (especially the corrosion of the reactor tank), as well as the obsolescence of many equipment and components of the reactor control and instrumentation system. Refurbishment works are being in process with the technical and financial supports from the Vietnam government and the IAEA. (author). 7 refs, 2 tabs, 10 figs

  8. Utilization of Innovations and Techniques of Educational Technology in Delivering of Educational Practicum and Its Impact on Increasing Academic Achievement among Pre-Service Teachers

    Science.gov (United States)

    Ibrahim, Hatim G.

    2017-01-01

    The current study aims to identify the utilization of innovations and techniques of educational technology in teaching of educational practicum and its impact on increasing academic achievement among pre-service teachers. The study sample consisted of (60) pre-service teachers (student teachers) randomly selected from public middle and secondary…

  9. Review of techniques and detectors used in instruments for field measurement of β doses and dose rates

    International Nuclear Information System (INIS)

    Jones, A.R.

    1984-01-01

    Generally, field measurements are required to assess the hazard from β-rays before personnel are allowed to occupy a working space or perform a task. Occasionally, the measurements are required for an assessment after a β-ray exposure is suspected to have occurred. With these uses of field instruments in mind, the following detectors and associated techniques will be discussed in terms of the measurement principles, advantages, and limitations: 1) thin-walled ion chambers (sometimes in combination with thick-walled ones or with covers thick enough to prevent penetration of β-particles); 2) thin scintillators, nearly tissue equivalent, to provide a detector analogous to skin; 3) scintillators, thick enough to absorb all the energy of the β-particles. Circuitry is required to count pulses according to size to permit calculation of dose or dose rate; 4) silicon diodes with thin detection layers operated as photocurrent generators; 5) silicon diodes, reversed biassed, with pulses counted according to size; 6) simple pulse counters (e.g., GM counters or silicon diodes with thin windows)

  10. Vibration monitoring/diagnostic techniques, as applied to reactor coolant pumps

    International Nuclear Information System (INIS)

    Sculthorpe, B.R.; Johnson, K.M.

    1986-01-01

    With the increased awareness of reactor coolant pump (RCP) cracked shafts, brought about by the catastrophic shaft failure at Crystal River number3, Florida Power and Light Company, in conjunction with Bently Nevada Corporation, undertook a test program at St. Lucie Nuclear Unit number2, to confirm the integrity of all four RCP pump shafts. Reactor coolant pumps play a major roll in the operation of nuclear-powered generation facilities. The time required to disassemble and physically inspect a single RCP shaft would be lengthy, monetarily costly to the utility and its customers, and cause possible unnecessary man-rem exposure to plant personnel. When properly applied, vibration instrumentation can increase unit availability/reliability, as well as provide enhanced diagnostic capability. This paper reviews monitoring benefits and diagnostic techniques applicable to RCPs/motor drives

  11. Irradiated fuel examination using the Cerenkov technique

    International Nuclear Information System (INIS)

    Nicholson, N.; Dowdy, E.J.

    1981-03-01

    A technique for monitoring irradiated nuclear fuel inventories located in water filled storage ponds has been developed and demonstrated. This technique provides sufficient qualitative information to be useful as a confirmatory technique to International Atomic Energy Agency inspectors. Measurements have been made on the Cerenkov glow light intensity from irradiated fuel that show the intensity of this light to be proportional to the cooling time. Fieldable instruments used in several tests confirm that such measurements can be made easily and rapidly, without fuel assembly movement or the introduction of apparatus into the storage ponds. The Cerenkov technique and instrumentation have been shown to be of potential use to operators of reactor spent fuel facilities and away from reactor storage facilities, and to the International Atomic Energy Agency inspectors who provide surveillance of the irradiated fuel stored in these facilities

  12. Epithermal neutron instrumentation at ISIS

    International Nuclear Information System (INIS)

    Gorini, G; Festa, G; Andreani, C

    2014-01-01

    The advent of pulsed neutron sources makes available high epithermal neutron fluxes (in the energy range between 500 meV and 100 eV). New dedicated instrumentation, such as Resonance Detectors, was developed at ISIS spallation neutron source in the last years to apply the specific properties of this kind of neutron beam to the study of condensed matter. New detection strategies like Filter Difference method and Foil Cycling Technique were also developed in parallel to the detector improvement at the VESUVIO beamline. Recently, epithermal neutron beams were also used at the INES beamline to study elemental and isotopic composition of materials, with special application to cultural heritage studies. In this paper we review a series of epithermal neutron instrumentation developed at ISIS, their evolution over time and main results obtained

  13. Angle measurement with laser feedback instrument.

    Science.gov (United States)

    Chen, Wenxue; Zhang, Shulian; Long, Xingwu

    2013-04-08

    An instrument for angle measurement based on laser feedback has been designed. The measurement technique is based on the principle that when a wave plate placed into a feedback cavity rotates, its phase retardation varies. Phase retardation is a function of the rotating angle of the wave plate. Hence, the angle can be converted to phase retardation. The phase retardation is measured at certain characteristic points identified in the laser outputting curve that are then modulated by laser feedback. The angle of a rotating object can be measured if it is connected to the wave plate. The main advantages of this instrument are: high resolution, compact, flexible, low cost, effective power, and fast response.

  14. Safeguards instrumentation: a computer-based catalog. Second edition

    International Nuclear Information System (INIS)

    Auerbach, C.

    1985-04-01

    This catalog contains entries on new developments and on items listed in BNL 51450, which have either been carried over unchanged or been updated. More than 70 entries were deleted because of either obsolescence, insufficient interest in terms of safeguards, or lack of documentable development activities in recent years. Some old listings as well as new material was consolidated into more generic entries. As in the earlier document, the emphasis is on devices and instruments that are either in field use at this time or under active development. A few items such as NDA reference materials, instrument vans and certain shipping containers are included because they are important adjuncts to optimum utilization of safeguards instrumentation. This catalog does not include devices for physical protection. As was the case with its predecessor, most of the material in this catalog originated in the US and Canada; a few contributions came from member states of the European Community

  15. Safeguards instrumentation: a computer-based catalog. Second edition

    Energy Technology Data Exchange (ETDEWEB)

    Auerbach, C.

    1985-04-01

    This catalog contains entries on new developments and on items listed in BNL 51450, which have either been carried over unchanged or been updated. More than 70 entries were deleted because of either obsolescence, insufficient interest in terms of safeguards, or lack of documentable development activities in recent years. Some old listings as well as new material was consolidated into more generic entries. As in the earlier document, the emphasis is on devices and instruments that are either in field use at this time or under active development. A few items such as NDA reference materials, instrument vans and certain shipping containers are included because they are important adjuncts to optimum utilization of safeguards instrumentation. This catalog does not include devices for physical protection. As was the case with its predecessor, most of the material in this catalog originated in the US and Canada; a few contributions came from member states of the European Community.

  16. Development of nuclear imaging instrument and software

    International Nuclear Information System (INIS)

    Kim, Jang Hee; Chung Jae Myung; Nam, Sang Won; Chang, Hyung Uk

    1999-03-01

    In the medical diagnosis, the nuclear medical instrument using the radioactive isotope are commonly utilized. In the foreign countries, the medical application and development of the most advanced nuclear medical instrument such as Single Photon Emission Computer Tomography (SPECT) and position emission tomograph (PET), have been extensively carried out. However, in Korea, such highly expensive instruments have been all, imported, paying foreign currency. Since 1997, much efforts, the development of the radio nuclide medical instrument, the drive of the domestic production, etc. have been made to establish our own technologies and to balance the international payments under the support of the Ministry of Science and Technology. At present time, 180 nuclear imaging instruments are now in operation and 60 of them are analog camera. In analog camera, the vector X-Y monitor is need for are image display. Since the analog camera, signal can not be process in the digital form, we have difficulties to transfer and store the image data. The image displayed at the monitor must be stored in the form of polaroid or X ray film. In order to discard these disadvantages, if we developed the computer interface system, the performance analog camera will be comparable with that of the digital camera. The final objective of the research is that using the interface system developed in this research, we reconstruct the image data transmitted to the personal computer in the form of the generalized data file

  17. US utility I ampersand C upgrade initiative

    International Nuclear Information System (INIS)

    Wilkinson, D.

    1993-01-01

    This paper describes an initiative which is being pursued to address the problems associated with the increasing obsolescence of instrumentation and control (I ampersand C) systems in nuclear power plants. Such efforts will improve safety, availability, and reliability of plant operation. The program presented is a joint plan between EPRI, utilities, and vendors, to bring about the development of technology to meet these needs, to encourage the private sector to develop such technology, and to prove to utilities the value and utility in applying such technology to upgrade their facilities. Part of this plan is demonstration programs where plant-wide sensor and I ampersand C improvements can be implemented, in a documented manner, to provide R ampersand D information on their performance, functionality, and reliability. The intent is to reduce the costs and shorten the learning curve associated with the utilization of modern I ampersand C equipment

  18. Interferences of commercial NO2 instruments in the urban atmosphere and in a smog chamber

    Directory of Open Access Journals (Sweden)

    J. Kleffmann

    2012-01-01

    Full Text Available Reliable measurements of atmospheric trace gases are necessary for both, a better understanding of the chemical processes occurring in the atmosphere, and for the validation of model predictions. Nitrogen dioxide (NO2 is a toxic gas and is thus a regulated air pollutant. Besides, it is of major importance for the oxidation capacity of the atmosphere and plays a pivotal role in the formation of ozone and acid precipitation. Detection of NO2 is a difficult task since many of the different commercial techniques used are affected by interferences. The chemiluminescence instruments that are used for indirect NO2 detection in monitoring networks and smog chambers use either molybdenum or photolytic converters and are affected by either positive (NOy or negative interferences (radical formation in the photolytic converter. Erroneous conclusions on NO2 can be drawn if these interferences are not taken into consideration. In the present study, NO2 measurements in the urban atmosphere, in a road traffic tunnel and in a smog-chamber using different commercial techniques, i.e. chemiluminescence instruments with molybdenum or photolytic converters, a Luminol based instrument and a new NO2-LOPAP, were compared with spectroscopic techniques, i.e. DOAS and FTIR. Interferences of the different instruments observed during atmospheric measurements were partly characterised in more detail in the smog chamber experiments. Whereas all the commercial instruments showed strong interferences, excellent agreement was obtained between a new NO2-LOPAP instrument and the FTIR technique for the measurements performed in the smog chamber.

  19. Advanced Measuring (Instrumentation Methods for Nuclear Installations: A Review

    Directory of Open Access Journals (Sweden)

    Wang Qiu-kuan

    2012-01-01

    Full Text Available The nuclear technology has been widely used in the world. The research of measurement in nuclear installations involves many aspects, such as nuclear reactors, nuclear fuel cycle, safety and security, nuclear accident, after action, analysis, and environmental applications. In last decades, many advanced measuring devices and techniques have been widely applied in nuclear installations. This paper mainly introduces the development of the measuring (instrumentation methods for nuclear installations and the applications of these instruments and methods.

  20. Techniques, processes, and measures for software safety and reliability

    International Nuclear Information System (INIS)

    Sparkman, D.

    1992-01-01

    The purpose of this report is to provide a detailed survey of current recommended practices and measurement techniques for the development of reliable and safe software-based systems. This report is intended to assist the United States Nuclear Reaction Regulation (NRR) in determining the importance and maturity of the available techniques and in assessing the relevance of individual standards for application to instrumentation and control systems in nuclear power generating stations. Lawrence Livermore National Laboratory (LLNL) provides technical support for the Instrumentation and Control System Branch (ICSB) of NRRin advanced instrumentation and control systems, distributed digital systems, software reliability, and the application of verificafion and validafion for the development of software