WorldWideScience

Sample records for instrumentation preliminary analysis

  1. Active cooling for downhole instrumentation: Preliminary analysis and system selection

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, G.A.

    1988-03-01

    A feasibility study and a series of preliminary designs and analyses were done to identify candidate processes or cycles for use in active cooling systems for downhole electronic instruments. A matrix of energy types and their possible combinations was developed and the energy conversion process for each pari was identified. The feasibility study revealed conventional as well as unconventional processes and possible refrigerants and identified parameters needing further clarifications. A conceptual design or series od oesigns for each system was formulated and a preliminary analysis of each design was completed. The resulting coefficient of performance for each system was compared with the Carnot COP and all systems were ranked by decreasing COP. The system showing the best combination of COP, exchangeability to other operating conditions, failure mode, and system serviceability is chosen for use as a downhole refrigerator. 85 refs., 48 figs., 33 tabs.

  2. Instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-15

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  3. Instrumental analysis

    International Nuclear Information System (INIS)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-01

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  4. Preliminary safety analysis report for project 89-GEB-610 Plutonium Finishing Plant instrumentation upgrade. Revision 1

    International Nuclear Information System (INIS)

    Huber, T.E.

    1995-01-01

    This document consists of an analysis of the MICON system upgrade. This project shall install a Micon Co. distributed process monitor and control system with Sparc Sun workstation operator interfaces. The Sparc workstations are housed in consoles custom designed to human factors specifications. The distributed control system (DCS) shall have the installed capacity to monitor and control all related instruments and equipment presently connected to the panels in the PFP Power Control Room 321A as listed in the input/output list. This also includes all devices monitored and controlled by the 2736-ZB Allen Bradley programmable logic controller. The system has since assumed the control and monitoring responsibilities for Projects B- 680H ''Low Level Waste Treatment Facility'' and C-031H ''PFP Liquid Effluent Facilities''. Part of the new en's change area in Building 234-5ZA, Room 712, has been remodeled to house two consoles and one supervisor console. Local control units containing the microprocontrollers and the input/output interface circuit boards shall be wired to the instrumentation and controlled equipment. These units communicate with the Sparc workstations via a redundant data communications highway and shall be strategic, throughout the PFP facility. The DCS has already been purchased from Micon Co., located in Houston Texas, presently on site

  5. Preliminary Analysis of Assessment Instrument Design to Reveal Science Generic Skill and Chemistry Literacy

    Science.gov (United States)

    Sumarni, Woro; Sudarmin; Supartono, Wiyanto

    2016-01-01

    The purpose of this research is to design assessment instrument to evaluate science generic skill (SGS) achievement and chemistry literacy in ethnoscience-integrated chemistry learning. The steps of tool designing refers to Plomp models including 1) Investigation Phase (Prelimenary Investigation); 2) Designing Phase (Design); 3)…

  6. The influence of evaluation recommendations on instrumental and conceptual uses: A preliminary analysis.

    Science.gov (United States)

    Bourgeois, Isabelle; Whynot, Jane

    2018-06-01

    Evaluation recommendations are sometimes included in evaluation reports to highlight specific actions to be taken to improve a program or to make other changes to its operational context. This preliminary study sought to examine evaluation recommendations drawn from 25 evaluation reports published by Canadian federal government departments and agencies, in order to examine the evaluation issues covered and the focus of the recommendations. Our results show that in keeping with policy requirements, the evaluation recommendations focused on program relevance, effectiveness and efficiency and economy. Furthermore, a significant number of recommendations also focused on the implementation of more rigorous performance measurement strategies. The focus of the recommendations did not vary by publication date, recommendation type, and organizational sector. The findings also show that for the most part, the management responses produced as part of the broader evaluation process support the recommendations included in the report and identify specific timelines for implementation. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. A preliminary study of archaeological ceramic from the Sao Paulo II, Brazil, archaeological site by Instrumental Neutron Activation Analysis (INAA)

    International Nuclear Information System (INIS)

    Ribeiro, Rogerio B.; Munita, Casimiro S.; Oliveira, Paulo M.S.; Neves, Eduardo G.; Tamahara, Eduardo K.

    2011-01-01

    The determination of trace elements plays an important role in the characterization of archaeological ceramics. It is well established that ceramics can be grouped based on similarities/dissimilarities derived from chemical data. Different analytical methods can be applied to determine the sample composition. Instrumental neutron activation analysis (INAA) is the method preferred because present several advantages in relation to the other techniques. In this work, the elements determined were As, K, La, Lu, Na, Nd, Sb, Sm, U, Yb, Ba, Ce, Co, Cr, Cs, I, Fe, Hf, Rb, Sc, Ta , Tb, Th and Zn to carry out a preliminary chemical characterization in 44 ceramic samples from Sao Paulo II archaeological site by INAA. The site is located in Coari city, 363 km from Manaus, Amazonas state (AM). The elementary concentration results were studied using multivariate statistical methods. The similarity/dissimilarity among the samples was studied by means of discriminant analysis. The compositions group classification was done through cluster analysis, showing the formation of the three distinct groups of the ceramics. (author)

  8. Instrumental analysis

    International Nuclear Information System (INIS)

    Jae, Myeong Gi; Lee, Won Seong; Kim, Ha Hyeok

    1989-02-01

    This book give description of electronic engineering such as circuit element and device, circuit analysis and logic digital circuit, the method of electrochemistry like conductometry, potentiometry and current measuring, spectro chemical analysis with electromagnetic radiant rays, optical components, absorption spectroscopy, X-ray analysis, atomic absorption spectrometry and reference, chromatography like gas-chromatography and liquid-chromatography and automated analysis on control system evaluation of automated analysis and automated analysis system and reference.

  9. Instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jae, Myeong Gi; Lee, Won Seong; Kim, Ha Hyeok

    1989-02-15

    This book give description of electronic engineering such as circuit element and device, circuit analysis and logic digital circuit, the method of electrochemistry like conductometry, potentiometry and current measuring, spectro chemical analysis with electromagnetic radiant rays, optical components, absorption spectroscopy, X-ray analysis, atomic absorption spectrometry and reference, chromatography like gas-chromatography and liquid-chromatography and automated analysis on control system evaluation of automated analysis and automated analysis system and reference.

  10. UVISS preliminary visibility analysis

    DEFF Research Database (Denmark)

    Betto, Maurizio

    1998-01-01

    The goal of this work is to obtain a preliminary assessment of the sky visibility for anastronomical telescope located on the express pallet of the International SpaceStation (ISS)} taking into account the major constraints imposed on the instrument by the ISSattitude and structure. Part of the w......The goal of this work is to obtain a preliminary assessment of the sky visibility for anastronomical telescope located on the express pallet of the International SpaceStation (ISS)} taking into account the major constraints imposed on the instrument by the ISSattitude and structure. Part...... of the work is also to setup the kernel of a software tool for the visibility analysis thatshould be easily expandable to consider more complex strucures for future activities.This analysis is part of the UVISS assessment study and it is meant to provide elementsfor the definition and the selection...

  11. The Thirty Gigahertz Instrument Receiver for the QUIJOTE Experiment: Preliminary Polarization Measurements and Systematic-Error Analysis

    Directory of Open Access Journals (Sweden)

    Francisco J. Casas

    2015-08-01

    Full Text Available This paper presents preliminary polarization measurements and systematic-error characterization of the Thirty Gigahertz Instrument receiver developed for the QUIJOTE experiment. The instrument has been designed to measure the polarization of Cosmic Microwave Background radiation from the sky, obtaining the Q, U, and I Stokes parameters of the incoming signal simultaneously. Two kinds of linearly polarized input signals have been used as excitations in the polarimeter measurement tests in the laboratory; these show consistent results in terms of the Stokes parameters obtained. A measurement-based systematic-error characterization technique has been used in order to determine the possible sources of instrumental errors and to assist in the polarimeter calibration process.

  12. Instrumental analysis, second edition

    International Nuclear Information System (INIS)

    Christian, G.D.; O'Reilly, J.E.

    1988-01-01

    The second edition of Instrumental Analysis is a survey of the major instrument-based methods of chemical analysis. It appears to be aimed at undergraduates but would be equally useful in a graduate course. The volume explores all of the classical quantitative methods and contains sections on techniques that usually are not included in a semester course in instrumentation (such as electron spectroscopy and the kinetic methods). Adequate coverage of all of the methods contained in this book would require several semesters of focused study. The 25 chapters were written by different authors, yet the style throughout the book is more uniform than in the earlier edition. With the exception of a two-chapter course in analog and digital circuits, the book purports to de-emphasize instrumentation, focusing more on the theory behind the methods and the application of the methods to analytical problems. However, a detailed analysis of the instruments used in each method is by no means absent. The book has the favor of a user's guide to analysis

  13. MANU. Instrumentation of Buffer Demo. Preliminary Study

    International Nuclear Information System (INIS)

    Laaksonen, R.

    2010-01-01

    The purpose of this work is to describe feasible measuring and monitoring alternatives which can be used, if needed, in medium to full scale nuclear waste repository deposition hole mock-up tests. The focus of the work was to determine what variables can actually be measured, how to achieve the measurements and what kind of demands comes from the modelling, scientific, and technical points of view. This project includes a review of the previous waste repository mock-up tests carried out in several European countries such as Belgium, Czech Republic, Spain and Sweden. Also information was gathered by interviewing domestic and foreign scientists specialized in the fields of measurement instrumentation and related in-situ and laboratory work. On the basis of this review, recommendations were developed for the necessary actions needed to be done from the instrumentation point of view for future tests. It is possible to measure and monitor the processes going on in a deposition hole in-situ conditions. The data received during a test in real repository conditions enables to follow the processes and to verify the hypothesis made on the behaviour of various components of the repository: buffer, canister, rock and backfill. Because full scale testing is expensive, the objectives and hypothesis must be carefully set and the test itself with its instrumentation must serve very specific objectives. The main purpose of mock-up tests is to verify that the conditions surrounding the canister are according to the design requirements. A whole mock-up test and demonstration process requires a lot of time and effort. The instrumentation part of the work must also start at early stages to ensure that the instrumentation itself will not become bottlenecked nor suffer from low quality solutions. The planning of the instrumentation work could be done in collaboration with foreign scientists which have participated to previous instrumentation projects. (orig.)

  14. Easy instrumental analysis

    International Nuclear Information System (INIS)

    Ko, Myeong Su; Kim, Tae Hwa; Park, Gyu Hyeon; Yang, Jong Beom; Oh, Chang Hwan; Lee, Kyoung Hye

    2010-04-01

    This textbook describes instrument analysis in easy way with twelve chapters. The contents of the book are pH measurement on principle, pH meter, pH measurement, examples of the experiments, centrifugation, Absorptiometry, Fluorescent method, Atomic absorption analysis, Gas-chromatography, Gas chromatography-mass spectrometry, High performance liquid chromatography liquid chromatograph-mass spectrometry, Electrophoresis on practical case and analysis of the result and examples, PCR on principle, device, application and examples and Enzyme-linked immunosorbent assay with indirect ELISA, sandwich ELISA and ELISA reader.

  15. Easy instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Myeong Su; Kim, Tae Hwa; Park, Gyu Hyeon; Yang, Jong Beom; Oh, Chang Hwan; Lee, Kyoung Hye

    2010-04-15

    This textbook describes instrument analysis in easy way with twelve chapters. The contents of the book are pH measurement on principle, pH meter, pH measurement, examples of the experiments, centrifugation, Absorptiometry, Fluorescent method, Atomic absorption analysis, Gas-chromatography, Gas chromatography-mass spectrometry, High performance liquid chromatography liquid chromatograph-mass spectrometry, Electrophoresis on practical case and analysis of the result and examples, PCR on principle, device, application and examples and Enzyme-linked immunosorbent assay with indirect ELISA, sandwich ELISA and ELISA reader.

  16. Pickering safeguards: a preliminary analysis

    International Nuclear Information System (INIS)

    Todd, J.L.; Hodgkinson, J.G.

    1977-05-01

    A summary is presented of thoughts relative to a systems approach for implementing international safeguards. Included is a preliminary analysis of the Pickering Generating Station followed by a suggested safeguards system for the facility

  17. Nuclear instrumentation evaluation and analysis

    International Nuclear Information System (INIS)

    Park, Suk Jun; Han, Sang Joon; Chung, Chong Eun; Han, Kwang Soo; Kim, Dong Hwa; Park, Byung Hae; Moon, Je Sun; Lee, Chel Kwon; Song, Ki Sang; Choi, Myung Jin; Kim, Seung Bok; Kim, Jung Bok

    1986-12-01

    This project provides the program for improving instrumentation reliability as well as developing a cost-effective preventive maintenance activity through evaluation and analysis of nuclear instrumentation concerning pilot plants, large-scale test facilities and various laboratories on KAERI site. In addition, it discusses the program for enhancing safe operations and improving facility availability through establishment of maintenance technology. (Author)

  18. Preliminary thermal architecture of the X-IFU instrument dewar

    Science.gov (United States)

    Charles, Ivan; Daniel, Christophe; André, Jérome; Duband, Lionel; Duval, Jean-Marc; den Hartog, Roland; Mitsuda, Kazuhisa; Shinozaki, Keisuke; van Weers, Henk; Yamasaki, Noriko Y.

    2016-07-01

    The ESA Athena mission will implement 2 instruments to study the hot and energetic universe. The X-ray Integral Field Unit (X-IFU) will provide spatially resolved high resolution spectroscopy. This high energy resolution of 2.5 eV at 7 keV could be achieved thanks to TES (Transition Edge Sensor) detectors that need to be cooled to very low temperature. To obtain the required 50 mK temperature level, a careful design of the cryostat and of the cooling chain including different technologies in cascade is needed. The preliminary cryogenic architecture of the X-IFU instrument that fulfils the TES detector thermal requirements is described. In particular, the thermal design of the detector focal plane assembly (FPA), that uses three temperature stages (from 2 K to 50 mK) to limit the thermal loads on the lowest temperature stage, is described. The baseline cooling chain is based on European and Japanese mechanical coolers (Stirling, Pulse tube and Joule Thomson coolers) that precool a sub Kelvin cooler made of a 3He sorption cooler coupled with a small ADR (Adiabatic Demagnetization Refrigerator). Preliminary thermal budgets of the X-IFU cryostat are presented and discussed regarding cooling chain performances.

  19. Pesticide Instrumental Analysis

    International Nuclear Information System (INIS)

    Samir, E.; Fonseca, E.; Baldyga, N.; Acosta, A.; Gonzalez, F.; Felicita, F.; Tomasso, M.; Esquivel, D.; Parada, A.; Enriquez, P.; Amilibia, M.

    2012-01-01

    This workshop was the evaluation of the pesticides impact on the vegetable matrix with the purpose to determine the analysis by GC / M S. The working material were lettuce matrix, chard and a mix of green leaves and pesticides.

  20. Jovian seismology: preliminary results of the SYMPA instrument

    Science.gov (United States)

    Gaulme, P.; Schmider, F. X.; Gay, J.; Jacob, C.; Jeanneaux, F.; Alvarez, M.; Reyes, M.; Valtier, J. C.; Fossat, E.; Palle, P. L.; Belmonte, J. C.; Gelly, B.

    2006-06-01

    Jupiter's internal structure is poorly known (Guillot et al. 2004). Seismology is a powerful tool to investigate the internal structure of planets and stars, by analyzing how acoustic waves propagate. Mosser (1997) and Gudkova & Zarkhov (1999) showed that the detection and the identification of non-radial modes up to degree ℓ=25 can constrain strongly the internal structure. SYMPA is a ground-based network project dedicated to the Jovian oscillations (Schmider et al. 2002). The instrument is composed of a Mach-Zehnder interferometer producing four interferograms of the planetary spectrum. The combination of the four images in phase quadrature allows the reconstruction of the incident light phase, which is related to the Doppler shift generated by the oscillations. Two SYMPA instruments were built at the Nice university and were used simultaneously during two observation campaigns, in 2004 and 2005, at the San Pedro Martir observatory (Mexico) and the Teide observatory (Las Canarias). We will present for the first time the data processing and the preliminary results of the experiment.

  1. Preliminary HECTOR analysis by Dragon

    Energy Technology Data Exchange (ETDEWEB)

    Presser, W; Woloch, F

    1972-06-02

    From the different cores measured in HECTOR, only ACH 4/B-B was selected for the Dragon analysis, since it presented the largest amount of uniform fuel loading in the central test region and is therefore nearest to an infinite lattice. Preliminary results are discussed.

  2. Instrumental activation analysis of molybdenites

    International Nuclear Information System (INIS)

    Geisler, M.; Schelhorn, H.

    1981-01-01

    Na, K, Sc, Cr, Fe, Co, Se, Rb, Ag, Cs, Ba, La, Ce, Eu, Yb, Hf, W, Re, and Th have been determined in 6 molybdenite samples by instrumental activation analysis. The samples were of different origin and showed K, Sc, W, and Re values with differences of more than two orders of magnitude, whereas Sc values were within one order of magnitude

  3. Soil analysis. Modern instrumental technique

    International Nuclear Information System (INIS)

    Smith, K.A.

    1993-01-01

    This book covers traditional methods of analysis and specialist monographs on individual instrumental techniques, which are usually not written with soil or plant analysis specifically in mind. The principles of the techniques are combined with discussions of sample preparation and matrix problems, and critical reviews of applications in soil science and related disciplines. Individual chapters are processed separately for inclusion in the appropriate data bases

  4. Concept Overview & Preliminary Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ruth, Mark

    2017-07-12

    'H2@Scale' is an opportunity for wide-scale use of hydrogen as an intermediate that carries energy from various production options to multiple uses. It is based on identifying and developing opportunities for low-cost hydrogen production and investigating opportunities for using that hydrogen across the electricity, industrial, and transportation sectors. One of the key production opportunities is use of low-cost electricity that may be generated under high penetrations of variable renewable generators such as wind and solar photovoltaics. The technical potential demand for hydrogen across the sectors is 60 million metric tons per year. The U.S. has sufficient domestic renewable resources so that each could meet that demand and could readily meet the demand using a portfolio of generation options. This presentation provides an overview of the concept and the technical potential demand and resources. It also motivates analysis and research on H2@Scale.

  5. Electrolytic preconcentration in instrumental analysis.

    Science.gov (United States)

    Sioda, R E; Batley, G E; Lund, W; Wang, J; Leach, S C

    1986-05-01

    The use of electrolytic deposition as a separation and preconcentration step in trace metal analysis is reviewed. Both the principles and applications of the technique are dealt with in some detail. Electrolytic preconcentration can be combined with a variety of instrumental techniques. Special attention is given to stripping voltammetry, potentiometric stripping analysis, different combinations with atomic-absorption spectrometry, and the use of flow-through porous electrodes. It is pointed out that the electrolytic preconcentration technique deserves more extensive use as well as fundamental investigation.

  6. Analysis of instrumentation technology for SMART

    International Nuclear Information System (INIS)

    Hur, Seop; Koo, I. S.; Park, H. Y.; Lee, C. K.; Kim, D. H.; Suh, Y. S.; Seong, S. H.; Jang, G. S.

    1998-03-01

    It is necessary that development requirements, techniques to be developed, and development tasks and approach are established to develop the SMART instrumentation system. It is important to establish the development strategies for input for developing SMART instrumentation system. To meet above needs, the industry general and nuclear instrumentation techniques were analyzed and reviewed, respectively, based on the classification of instrumentation to analyze the industrial instrumentation techniques, and analysis results which described the inherent merits and demerits of each technique can be used for inputs to select the instruments for SMART. For the instrumentation techniques for nuclear environments, the major instrumentation techniques were reviewed, and the instrumentation system were established. The following development approaches were established based on the development requirements and the analysis results of research and development trends of industrial and nuclear instrumentation techniques. (author). 90 refs., 38 tabs., 33 figs

  7. Preliminary hazards analysis -- vitrification process

    International Nuclear Information System (INIS)

    Coordes, D.; Ruggieri, M.; Russell, J.; TenBrook, W.; Yimbo, P.

    1994-06-01

    This paper presents a Preliminary Hazards Analysis (PHA) for mixed waste vitrification by joule heating. The purpose of performing a PHA is to establish an initial hazard categorization for a DOE nuclear facility and to identify those processes and structures which may have an impact on or be important to safety. The PHA is typically performed during and provides input to project conceptual design. The PHA is then followed by a Preliminary Safety Analysis Report (PSAR) performed during Title 1 and 2 design. The PSAR then leads to performance of the Final Safety Analysis Report performed during the facility's construction and testing. It should be completed before routine operation of the facility commences. This PHA addresses the first four chapters of the safety analysis process, in accordance with the requirements of DOE Safety Guidelines in SG 830.110. The hazards associated with vitrification processes are evaluated using standard safety analysis methods which include: identification of credible potential hazardous energy sources; identification of preventative features of the facility or system; identification of mitigative features; and analyses of credible hazards. Maximal facility inventories of radioactive and hazardous materials are postulated to evaluate worst case accident consequences. These inventories were based on DOE-STD-1027-92 guidance and the surrogate waste streams defined by Mayberry, et al. Radiological assessments indicate that a facility, depending on the radioactive material inventory, may be an exempt, Category 3, or Category 2 facility. The calculated impacts would result in no significant impact to offsite personnel or the environment. Hazardous materials assessment indicates that a Mixed Waste Vitrification facility will be a Low Hazard facility having minimal impacts to offsite personnel and the environment

  8. Preliminary hazards analysis -- vitrification process

    Energy Technology Data Exchange (ETDEWEB)

    Coordes, D.; Ruggieri, M.; Russell, J.; TenBrook, W.; Yimbo, P. [Science Applications International Corp., Pleasanton, CA (United States)

    1994-06-01

    This paper presents a Preliminary Hazards Analysis (PHA) for mixed waste vitrification by joule heating. The purpose of performing a PHA is to establish an initial hazard categorization for a DOE nuclear facility and to identify those processes and structures which may have an impact on or be important to safety. The PHA is typically performed during and provides input to project conceptual design. The PHA is then followed by a Preliminary Safety Analysis Report (PSAR) performed during Title 1 and 2 design. The PSAR then leads to performance of the Final Safety Analysis Report performed during the facility`s construction and testing. It should be completed before routine operation of the facility commences. This PHA addresses the first four chapters of the safety analysis process, in accordance with the requirements of DOE Safety Guidelines in SG 830.110. The hazards associated with vitrification processes are evaluated using standard safety analysis methods which include: identification of credible potential hazardous energy sources; identification of preventative features of the facility or system; identification of mitigative features; and analyses of credible hazards. Maximal facility inventories of radioactive and hazardous materials are postulated to evaluate worst case accident consequences. These inventories were based on DOE-STD-1027-92 guidance and the surrogate waste streams defined by Mayberry, et al. Radiological assessments indicate that a facility, depending on the radioactive material inventory, may be an exempt, Category 3, or Category 2 facility. The calculated impacts would result in no significant impact to offsite personnel or the environment. Hazardous materials assessment indicates that a Mixed Waste Vitrification facility will be a Low Hazard facility having minimal impacts to offsite personnel and the environment.

  9. High-performance instruments in neutron arena of JHP. Preliminary version

    International Nuclear Information System (INIS)

    Furusaka, M.; Itoh, S.; Otomo, T.; Arai, M.

    1996-05-01

    This report is a preliminary report of high-performance instruments in neutron arena of JHP (Japan Hadron Project). This report consists of as follows; neutron intensity of neutron arena, development of neutron sources in neutron arena, experimental devices and instrumentation. (J.P.N.)

  10. LISA Pathfinder instrument data analysis

    Science.gov (United States)

    Guzman, Felipe

    LISA Pathfinder (LPF) is an ESA-launched demonstration mission of key technologies required for the joint NASA-ESA gravitational wave observatory in space, LISA. As part of the LPF interferometry investigations, analytic models of noise sources and corresponding noise subtrac-tion techniques have been developed to correct for effects like the coupling of test mass jitter into displacement readout, and fluctuations of the laser frequency or optical pathlength difference. Ground testing of pre-flight hardware of the Optical Metrology Subsystem is currently ongoing at the Albert Einstein Institute Hannover. In collaboration with NASA Goddard Space Flight Center, the LPF mission data analysis tool LTPDA is being used to analyze the data product of these tests. Furthermore, the noise subtraction techniques and in-flight experiment runs for noise characterization are being defined as part of the mission experiment master plan. We will present the data analysis outcome of pre-flight hardware ground tests and possible noise subtraction strategies for in-flight instrument operations.

  11. Long range radio tracking of sea turtles and polar bear: Instrumentation and preliminary results

    Science.gov (United States)

    Baldwin, H. A.

    1972-01-01

    Instrumentation developed for studies of path behavior of the green sea turtle and migration movement of polar bear is described. Preliminary results bearing on navigation ability in these species are presented. Both species operate in difficult environments, and the problems faced in the design of electronic instrumentation for these studies are not completely specified at this time. However, the critical factors yet to be understood are primarily related to the behavior of instrumented animals. The data obtained with these experimental techniques are included, first to illustrate the technique and, second to provide initial preliminary results bearing on animal navigation.

  12. Preliminary Context Analysis of Community Informatics Social ...

    African Journals Online (AJOL)

    Preliminary context analysis is always part of the feasibility study phase in the development of information system for Community Development (CD) purposes. In this paper, a context model and a preliminary context analysis are presented for Social Network Web Application (SNWA) for CD in the Niger Delta region of ...

  13. MITS instrumentation error analysis report

    International Nuclear Information System (INIS)

    Nelson, D.W.; Hillon, D.D.

    1980-01-01

    The MITS (Machine Interface Test System) installation consists of three types of process monitoring and control instrumentation: flow, pressure, and temperature. An effort has been made to assess the various instruments used and assign a value to the accuracy that can be expected. Efforts were also made to analyze the calibration and installation procedures to be used and determine how these might effect the system accuracy

  14. Laparoendoscopic pfannenstiel nephrectomy using conventional laparoscopic instruments - preliminary experience

    Directory of Open Access Journals (Sweden)

    Anibal W. Branco

    2010-12-01

    Full Text Available PURPOSE: To confirm the feasibility of the laparoendoscopic Pfannenstiel nephrectomy using conventional laparoscopic instruments. MATERIALS AND METHODS: Since March 2009, laparoscopic nephrectomy through a Pfannenstiel incision has been performed in selected patients in our service. The Veress needle was placed through the umbilicus which allowed carbon dioxide inflow. One 5 mm (or 10 mm trocar was placed at the umbilicus for the laparoscope, to guide the placement of three trocars over the Pfannenstiel incision. Additional trocars were placed as follows: a 10 mm in the midline, a 10 mm ipsilateral to the kidney to be removed (2 cm away from the middle one, and a 5 mm contralateral to the kidney to be removed (2 cm away from the middle one. The entire procedure was performed using conventional laparoscopic instruments. At the end of the surgery, trocars were removed and all three incisions were united into a single Pfannenstiel incision for specimen retrieval. RESULTS: Five nephrectomies were performed following this technique: one atrophic kidney, one kidney donation, two renal cancers and one bilateral renal atrophy. Median operative time was 100 minutes and median intraoperative blood loss was 100 cc. No intraoperative complications occurred and no patients required blood transfusion. Median length of hospital stay was 1 day (range 1 to 2 days. CONCLUSIONS: The use of the Pfannenstiel incision for laparoscopic nephrectomy seems to be feasible even when using conventional laparoscopic instruments, and can be considered a potential alternative for traditional laparoscopic nephrectomy.

  15. Instrumental neutron activation analysis - a routine method

    International Nuclear Information System (INIS)

    Bruin, M. de.

    1983-01-01

    This thesis describes the way in which at IRI instrumental neutron activation analysis (INAA) has been developed into an automated system for routine analysis. The basis of this work are 20 publications describing the development of INAA since 1968. (Auth.)

  16. Preliminary investigations on TINI based distributed instrumentation systems

    International Nuclear Information System (INIS)

    Bezboruah, T.; Kalita, M.

    2006-04-01

    A prototype web enabled distributed instrumentation system is being proposed in the Department of Electronics Science, Gauhati University, Assam, India. The distributed instrumentation system contains sensors, legacy hardware, TCP/IP protocol converter, TCP/IP network Ethernet, Database Server, Web/Application Server and Client PCs. As part of the proposed work, Tiny Internet Interface (TINI, TBM390: Dallas Semiconductor) has been deployed as TCP/IP stack, and java programming language as software tools. A feature supported by Java, that is particularly relevant to the distributed system is its applet. An applet is a java class that can be downloaded from the web server and can be run in a context application such as web browser or an applet viewer. TINI has been installed as TCP/IP stack, as it is the best suited embedded system with java programming language and it has been uniquely designed for communicating over One Wire Devices (OWD) over network. Here we will discuss the hardware and software aspects of TINI with OWD for the present system. (author)

  17. Instrumental concept and preliminary performances of SIFTI: static infrared fourier transform interferometer

    Science.gov (United States)

    Hébert, Philippe-Jean; Cansot, E.; Pierangelo, C.; Buil, C.; Bernard, F.; Loesel, J.; Trémas, T.; Perrin, L.; Courau, E.; Casteras, C.; Maussang, I.; Simeoni, D.

    2017-11-01

    The SIFTI (Static Infrared Fourier Transform Interferometer) instrument aims at supporting an important part in a mission for atmospheric pollution sounding from space, by providing high spectral resolution and high Signal to Noise Ratio spectra of the atmosphere. They will allow to resolve tropospheric profiles of ozone (03) and carbon monoxide (C0), especially down to the planetary boundary layer (PBL), an altitude region of very high interest, though poorly monitored to date, for air quality and pollution monitoring. The retrieved profile of ozone, resp. C0, will contain 5 to 7, resp. 2.5 to 4, independent pieces of information. The French space agency CNES (Centre National d'Etudes Spatiales) has proposed and is studying an instrument concept for SIFTI based on a static interferometer, where the needed optical path are generated by a pair of crossed staircase fixed mirrors (replacing the moving reflector of dynamic Fourier transform interferometers like IASI or MIPAS). With the SIFTI design, a very high spectral resolution ( 0.1 cm-1 apodised) is achieved in a very compact optical setup, allowing a large throughput, hence a high SNR. The measurements are performed in the 9.5 μm band for 03 and in the 4.6 μm band for C0. The science return of the sounder can be further increased if an "intelligent pointing" process is implemented. This consists in combining the TIR sounder with a companion TIR imager, providing information on the cloud coverage in the next observed scene. 0nboard, real-time analysis of the IR image is used to command the sounder staring mirror to cloud free areas, which will maximize the probability for probing down to the surface. After the first part of the phase A, the architecture of SIFTI was studied as a trade-off between performance and resource budget. We review the main architecture and functional choices, and their advantages. The preliminary instrument concept is then presented in its main aspects and in terms of main subsystem

  18. Original Article PRELIMINARY BIOAUTOGRAPHIC ANALYSIS OF ...

    African Journals Online (AJOL)

    PRELIMINARY BIOAUTOGRAPHIC ANALYSIS OF THE SEEDS OF GLYPHAEA BREVIS. (SPRENG) MONACHINO FOR ANTIOXIDANT AND ANTIBACTERIAL PRINCIPLES. Michael Lahai1, Tiwalade Adewale Olugbade2. 1Department of Pharmaceutical Chemistry, Faculty of Pharmaceutical Sciences, College of Medicine ...

  19. Preliminary Analysis of Reinforced Concrete Waffle Walls

    National Research Council Canada - National Science Library

    Shugar, Theodore

    1997-01-01

    A preliminary analytical method based upon modified plate bending theory is offered for structural analysis of a promising new construction method for walls of small buildings and residential housing...

  20. Instrumental methods of analysis, 7th edition

    International Nuclear Information System (INIS)

    Willard, H.H.; Merritt, L.L. Jr.; Dean, J.A.; Settle, F.A. Jr.

    1988-01-01

    The authors have prepared an organized and generally polished product. The book is fashioned to be used as a textbook for an undergraduate instrumental analysis course, a supporting textbook for graduate-level courses, and a general reference work on analytical instrumentation and techniques for professional chemists. Four major areas are emphasized: data collection and processing, spectroscopic instrumentation and methods, liquid and gas chromatographic methods, and electrochemical methods. Analytical instrumentation and methods have been updated, and a thorough citation of pertinent recent literature is included

  1. Preliminary Report of Instrumentation in Tuberculous Lumbosacral Spine

    Directory of Open Access Journals (Sweden)

    T Zin-Naing

    2014-11-01

    Full Text Available The aims of spinal tuberculosis treatment are to eradicate the disease, to prevent the development of paraplegia and kyphotic deformity, to manage the existing deformity and neurological deficit, to allow early ambulation and to return the patient back to daily life. Methods for the treatment of tuberculosis of vertebra are still controversial. Conservative treatment includes medical therapy as well as external supports and surgery is indicated for deformity of spine, severe pain, or neurological compromise conditions. Most cases in our country were late presentations with disc space already infected, and after débridement there was a large gap needing bone graft to enhance bony fusion and anterior column support. Although the spine was infected, instrumentation posed no additional hazard in terms of tuberculous discitis. Oga et al. reported that M. tuberculosis has low adhesion capability and forms only a few microcolonies surrounded by a biofilm. Moon et al. stated that interbody fusion performed with classical anterior radical surgery per se was ineffective in the correction of kyphosis and did not prevent the increase in kyphosis angle. The present study focuses on collected clinical and radiographic outcomes in ten patients who underwent Posterior Lumbar Interbody Fusion (PLIF for tuberculous lumbosacral spine. All the cases had instability with kyphotic deformity or loss of lordosis. Clinical outcomes were measured by Visual Analogue Scale (VAS, modified MacNab Criteria, and radiographic outcomes (segmental kyphotic angle and total lumbar lordotic, TLL, angle on follow-up to six months. The mean VAS back scores showed decrease, and kyphotic angles and lordotic angles improved. Three cases had excellent results, six good and one fair using the modified MacNab criteria.

  2. Hydrothermal Liquefaction Treatment Preliminary Hazard Analysis Report

    Energy Technology Data Exchange (ETDEWEB)

    Lowry, Peter P.; Wagner, Katie A.

    2015-08-31

    A preliminary hazard assessment was completed during February 2015 to evaluate the conceptual design of the modular hydrothermal liquefaction treatment system. The hazard assessment was performed in 2 stages. An initial assessment utilizing Hazard Identification and Preliminary Hazards Analysis (PHA) techniques identified areas with significant or unique hazards (process safety-related hazards) that fall outside of the normal operating envelope of PNNL and warranted additional analysis. The subsequent assessment was based on a qualitative What-If analysis. This analysis was augmented, as necessary, by additional quantitative analysis for scenarios involving a release of hazardous material or energy with the potential for affecting the public.

  3. Conference on instrumental activation analysis - IAA 89

    International Nuclear Information System (INIS)

    Vobecky, M.; Obrusnik, I.

    1989-05-01

    The proceedings contain 40 abstracts of papers all of which have been incorporated in INIS. The papers were centred on the applications of radioanalytical methods, especialy on neutron activation analysis, X-ray fluorescence analysis, PIXE analysis and tracer techniques in biology, medicine and metallurgy, measuring instruments including microcomputers, and data processing methods. (J.P.)

  4. Conference on instrumental activation analysis IAA 92

    International Nuclear Information System (INIS)

    Frana, J.; Obrusnik, I.

    1992-05-01

    The publication contains 26 abstracts primarily concerned with neutron activation analysis, although other analytical techniques based on X-ray fluorescence analysis, PIXE, PIGE, RBS are also included. Some contributions deal with aspects of quality practice and assurance in radioanalytical laboratories, with marketing of instrumental neutron activation analysis services, with hard- and software aspects of radiation detection, etc. (Z.S.)

  5. The proposed Diagnostic Instrumentation and Analysis Laboratory, Mississippi State University

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-11-01

    The Department of Energy (DOE) proposes to authorize Mississippi State University (MSU) to proceed with the detailed design, construction and equipping of the proposed Diagnostic Instrumentation and Analysis Laboratory (DIAL). DOE grant funds are available to the University for the limited purpose of performing preliminary studies, including analysis necessary to conduct this environmental assessment. The proposed facility would be located in the Mississippi Research and Technology Park, adjacent to the Mississippi Agriculture and Forestry Experiment Station campus in Starkville, Mississippi. Total project cost is estimated at $7,953,600. This proposed laboratory would be designed to conduct research into combustion devices related to waste management and environmental restoration that is of importance to industry and government. The proposed facility`s role would be to develop diagnostic instrumentation capabilities in the area of combustion and related processes.

  6. Surveillance of instruments by noise analysis

    International Nuclear Information System (INIS)

    Thie, J.A.

    1981-01-01

    Random fluctuations of neutron flux, temperature, and pressure in a reactor provide multifrequency excitation of the corresponding instrumentation chains. Mathematical descriptors suitable for characterizing the output, or noise, of the instrumentation are reviewed with a view toward using such noise in detecting instrument faults. Demonstrations of the feasibility of this approach in a number of reactors provide illustrative examples. Comparisons with traditional surveillance testing are made, and a number of advantages and some disadvantages of using noise analysis as a supplementary technique are pointed out

  7. Development and preliminary validation of a post-fistula repair reintegration instrument among Ugandan women.

    Science.gov (United States)

    El Ayadi, Alison; Nalubwama, Hadija; Barageine, Justus; Neilands, Torsten B; Obore, Susan; Byamugisha, Josaphat; Kakaire, Othman; Mwanje, Haruna; Korn, Abner; Lester, Felicia; Miller, Suellen

    2017-09-02

    Obstetric fistula is a debilitating and traumatic birth injury affecting 2-3 million women globally, mostly in sub-Saharan Africa and Asia. Affected women suffer physically, psychologically and socioeconomically. International efforts have increased access to surgical treatment, yet attention to a holistic outcome of post-surgical rehabilitation is nascent. We sought to develop and pilot test a measurement instrument to assess post-surgical family and community reintegration. We conducted an exploratory sequential mixed-methods study, beginning with 16 in-depth interviews and four focus group discussions with 17 women who underwent fistula surgery within two previous years to inform measure development. The draft instrument was validated in a longitudinal cohort of 60 women recovering from fistula surgery. Qualitative data were analyzed through thematic analysis. Socio-demographic characteristics were described using one-way frequency tables. We used exploratory factor analysis to determine the latent structure of the scale, then tested the fit of a single higher-order latent factor. We evaluated internal consistency and temporal stability reliability through Raykov's ρ and Pearson's correlation coefficient, respectively. We estimated a series of linear regression models to explore associations between the standardized reintegration measure and validated scales representing theoretically related constructs. Themes central to women's experiences following surgery included resuming mobility, increasing social interaction, improved self-esteem, reduction of internalized stigma, resuming work, meeting their own needs and the needs of dependents, meeting other expected and desired roles, and negotiating larger life issues. We expanded the Return to Normal Living Index to reflect these themes. Exploratory factor analysis suggested a four-factor structure, titled 'Mobility and social engagement', 'Meeting family needs', 'Comfort with relationships', and 'General life

  8. An Instrument to Assess Self-Statements During Public Speaking: Scale Development and Preliminary Psychometric Properties

    Science.gov (United States)

    Hofmann, Stefan G.; DiBartolo, Patricia Marten

    2006-01-01

    Public speaking is the most commonly reported fearful social situation. Although a number of contemporary theories emphasize the importance of cognitive processes in social anxiety, there is no instrument available to assess fearful thoughts experienced during public speaking. The Self-Statements During Public Speaking (SSPS) scale is a 10-item questionnaire consisting of two 5-item subscales, the “Positive Self-Statements” (SSPS-P) and the “Negative Self-Statements” subscale (SSPS-N). Four studies report on the development and the preliminary psychometric properties of this instrument. PMID:16763666

  9. Preliminary safety analysis methodology for the SMART

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Kyoo Hwan; Chung, Y. J.; Kim, H. C.; Sim, S. K.; Lee, W. J.; Chung, B. D.; Song, J. H. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-03-01

    This technical report was prepared for a preliminary safety analysis methodology of the 330MWt SMART (System-integrated Modular Advanced ReacTor) which has been developed by Korea Atomic Energy Research Institute (KAERI) and funded by the Ministry of Science and Technology (MOST) since July 1996. This preliminary safety analysis methodology has been used to identify an envelope for the safety of the SMART conceptual design. As the SMART design evolves, further validated final safety analysis methodology will be developed. Current licensing safety analysis methodology of the Westinghouse and KSNPP PWRs operating and under development in Korea as well as the Russian licensing safety analysis methodology for the integral reactors have been reviewed and compared to develop the preliminary SMART safety analysis methodology. SMART design characteristics and safety systems have been reviewed against licensing practices of the PWRs operating or KNGR (Korean Next Generation Reactor) under construction in Korea. Detailed safety analysis methodology has been developed for the potential SMART limiting events of main steam line break, main feedwater pipe break, loss of reactor coolant flow, CEA withdrawal, primary to secondary pipe break and the small break loss of coolant accident. SMART preliminary safety analysis methodology will be further developed and validated in parallel with the safety analysis codes as the SMART design further evolves. Validated safety analysis methodology will be submitted to MOST as a Topical Report for a review of the SMART licensing safety analysis methodology. Thus, it is recommended for the nuclear regulatory authority to establish regulatory guides and criteria for the integral reactor. 22 refs., 18 figs., 16 tabs. (Author)

  10. Preliminary failure mode and effect analysis

    International Nuclear Information System (INIS)

    Addison, J.V.

    1972-01-01

    A preliminary Failure Mode and Effect Analysis (FMEA) was made on the overall 5 Kwe system. A general discussion of the system and failure effect is given in addition to the tabulated FMEA and a primary block diagram of the system. (U.S.)

  11. Preliminary safety analysis report for the TFTR

    International Nuclear Information System (INIS)

    Lind, K.E.; Levine, J.D.; Howe, H.J.

    A Preliminary Safety Analysis Report has been prepared for the Tokamak Fusion Test Reactor. No accident scenarios have been identified which would result in exposures to on-site personnel or the general public in excess of the guidelines defined for the project by DOE

  12. Malware Instrumentation Application to Regin Analysis

    Directory of Open Access Journals (Sweden)

    Matthieu Kaczmarek

    2015-12-01

    Full Text Available The complexity of the Regin malware underlines the importance of reverse engineering in modern incident response. The present study shows that such complexity can be overcome: substantial information about adversary tactics, techniques and procedures is obtained from reverse engineering. An introduction to the Regin development framework is provided along with instrumentation guidelines. Such instrumentation enables experimentation with malware modules. So analysis can derectly leverage malware’s own code without the need to program an analysis toolkit. As an application of the presented instrumentation, the underlying botnet architecture is analysed. Finally conclusions from different perspectives are provided: defense, attack and counter intelligence.

  13. Licensing Support System: Preliminary data scope analysis

    International Nuclear Information System (INIS)

    1989-01-01

    The purpose of this analysis is to determine the content and scope of the Licensing Support System (LSS) data base. Both user needs and currently available data bases that, at least in part, address those needs have been analyzed. This analysis, together with the Preliminary Needs Analysis (DOE, 1988d) is a first effort under the LSS Design and Implementation Contract toward developing a sound requirements foundation for subsequent design work. These reports are preliminary. Further refinements must be made before requirements can be specified in sufficient detail to provide a basis for suitably specific system specifications. This document provides a baseline for what is known at this time. Additional analyses, currently being conducted, will provide more precise information on the content and scope of the LSS data base. 23 refs., 4 figs., 8 tabs

  14. Work-nonwork interference: Preliminary results on the psychometric properties of a new instrument

    Directory of Open Access Journals (Sweden)

    Eileen Koekemoer

    2010-11-01

    Research purpose: The objectives of this study were to investigate the internal validity (construct, discriminant and convergent validity, reliability and external validity (relationship with theoretically relevant variables, including job characteristics, home characteristics, burnout, ill health and life satisfaction of the instrument. Motivation for the study: Work-family interaction is a key topic receiving significant research attention. In order to facilitate comparison across work-family studies, the use of psychometrically sound instruments is of great importance. Research design, approach and method: A cross-sectional survey design was used for the target population of married employees with children working at a tertiary institution in the North West province (n = 366. In addition to the new instrument, job characteristics, home characteristics, burnout, ill health and life satisfaction were measured. Main findings: The results provided evidence for construct, discriminant and convergent validity, reliability and significant relations with external variables. Practical/managerial implications: The new instrument can be used by researchers and managers as a test under development to investigate the interference between work and different nonwork roles (i.e. parental role, spousal role, work role, domestic role and specific relations with antecedents (e.g. job/home characteristics and well-being (e.g. burnout, ill health and life satisfaction. Contribution/value-add: This study provides preliminary information on the psychometric properties of a new instrument that measures the interference between work and nonwork.

  15. Preliminary Analysis of Google+'s Privacy

    OpenAIRE

    Mahmood, Shah; Desmedt, Yvo

    2011-01-01

    In this paper we provide a preliminary analysis of Google+ privacy. We identified that Google+ shares photo metadata with users who can access the photograph and discuss its potential impact on privacy. We also identified that Google+ encourages the provision of other names including maiden name, which may help criminals performing identity theft. We show that Facebook lists are a superset of Google+ circles, both functionally and logically, even though Google+ provides a better user interfac...

  16. Principle And Practice Of Instrumental Analysis

    International Nuclear Information System (INIS)

    Kim, Chong Il; Kim, Chang Gyo; Oh, Yong Taek

    2010-03-01

    This book gives descriptions of instrumental analysis, which includes quantum physics and chemical foundation with Bohr's adatom model and structure of an electron of atom and the periodic table, analytical theory on analytical chemistry and chemometrics, measurement uncertainty and probability and statistics, state of crystalline materials, structure of crystalline materials, spectroscopy, like infrared spectroscopy and near infrared spectroscopy, electro spectroscopy, mass spectroscopy and Atomic spectroscopy.

  17. Use of electronic computers for processing of spectrometric data in instrument neutron activation analysis

    International Nuclear Information System (INIS)

    Vyropaev, V.Ya.; Zlokazov, V.B.; Kul'kina, L.I.; Maslov, O.D.; Fefilov, B.V.

    1977-01-01

    A computer program is described for processing gamma spectra in the instrumental activation analysis of multicomponent objects. Structural diagrams of various variants of connection with the computer are presented. The possibility of using a mini-computer as an analyser and for preliminary processing of gamma spectra is considered

  18. Development and preliminary validation of a leadership competency instrument for existing and emerging allied health professional leaders.

    Science.gov (United States)

    Ang, Hui-Gek; Koh, Jeremy Meng-Yeow; Lee, Jeffrey; Pua, Yong-Hao

    2016-02-19

    No instruments, to our knowledge, exist to assess leadership competency in existing and emerging allied health professional (AHP) leaders. This paper describes the development and preliminary exploration of the psychometric properties of a leadership competency instrument for existing and emerging AHP leaders and examines (i) its factor structure, (ii) its convergent validity with the Leadership Practices Inventory (LPI), and (iii) its discriminative validity in AHPs with different grades. During development, we included 25 items in the AHEAD (Aspiring leaders in Healthcare-Empowering individuals, Achieving excellence, Developing talents) instrument. A cross-sectional study was then conducted in 106 high-potential AHPs from Singapore General Hospital (34 men and 72 women) of different professional grades (49 principal-grade AHPs, 41 senior-grade AHPs, and 16 junior-grade AHPs) who completed both AHEAD and LPI instruments. Exploratory factor analysis was used to test the theoretical structure of AHEAD. Spearman correlation analysis was performed to evaluate the convergent validity of AHEAD with LPI. Using proportional odds regression models, we evaluated the association of grades of AHPs with AHEAD and LPI. To assess discriminative validity, the c-statistics - a measure of discrimination - were derived from these ordinal models. As theorized, factor analysis suggested a two-factor solution, where "skills" and "values" formed separate factors. Internal consistency of AHEAD was excellent (α-values > 0.88). Total and component AHEAD and LPI scores correlated moderately (Spearman ρ-values, 0.37 to 0.58). The c-index for discriminating between AHP grades was higher for AHEAD than for the LPI (0.76 vs. 0.65). The factorial structure of AHEAD was generally supported in our study. AHEAD showed convergent validity with the LPI and outperformed the LPI in terms of discriminative validity. These results provide initial evidence for the use of AHEAD to assess leadership

  19. Instrumental Neutron Activation Analysis in archaeology interpretation beyond elemental abundance

    International Nuclear Information System (INIS)

    Bishop, Ronald L.

    2001-01-01

    Application of instrumental neutron activation analysis to the study of archaeological ceramics involves the determination of the source or sources used to produce pottery. Groups of relatively homogeneous elemental abundances are shown to be statically distinct from one another often leading to the assesment of what was locally produced and what was imported to a site. These assesment, however are among the most preliminary interpretations. Archaeology is concerned with the reasons for artificial distributions and how and why the distribution varied through time 3 reasons that include the social and political basis of ancient economics and how these responded to other factors, such as ideology. These objectives are addressed through the increasing refinement of compositional groups leading toward greater specificity of attribution. In so doing the role of analytical precision among other considerations groves in importance. This paper illustration some of these considerations with examples from the U.S. southwest, the Maya region of southern mexico, and lower central America

  20. Instrumental neutron activation analysis of soil sample

    International Nuclear Information System (INIS)

    Abdul Khalik Haji Wood.

    1983-01-01

    This paper describes the analysis of soil samples collected from 5 different location around Sungai Lui, Kajang, Selangor, Malaysia. These sample were taken at 22-24 cm from the top of the ground and were analysed using the techniques of Instrumental Neutron Activation Analysis (INAA). The analysis on soil sample taken above 22-24 cm level were done in order to determine if there is any variation in elemental contents at different sampling levels. The results indicate a wide variation in the contents of the samples. About 30 elements have been analysed. The major ones are Na, I, Cl, Mg, Al, K, Ti, Ca and Fe. Trace elements analysed were Ba, Sc, V, Cr, Mn, Ga, As, Zn, Br, Rb, Co, Hf, Zr, Th, U, Sb, Cs, Ce, Sm, Eu, Tb, Dy, Yb, Lu and La. (author)

  1. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  2. Preliminary Hazards Analysis Plasma Hearth Process

    International Nuclear Information System (INIS)

    Aycock, M.; Coordes, D.; Russell, J.; TenBrook, W.; Yimbo, P.

    1993-11-01

    This Preliminary Hazards Analysis (PHA) for the Plasma Hearth Process (PHP) follows the requirements of United States Department of Energy (DOE) Order 5480.23 (DOE, 1992a), DOE Order 5480.21 (DOE, 1991d), DOE Order 5480.22 (DOE, 1992c), DOE Order 5481.1B (DOE, 1986), and the guidance provided in DOE Standards DOE-STD-1027-92 (DOE, 1992b). Consideration is given to ft proposed regulations published as 10 CFR 830 (DOE, 1993) and DOE Safety Guide SG 830.110 (DOE, 1992b). The purpose of performing a PRA is to establish an initial hazard categorization for a DOE nuclear facility and to identify those processes and structures which may have an impact on or be important to safety. The PHA is typically performed during and provides input to project conceptual design. The PRA then is followed by a Preliminary Safety Analysis Report (PSAR) performed during Title I and II design. This PSAR then leads to performance of the Final Safety Analysis Report performed during construction, testing, and acceptance and completed before routine operation. Radiological assessments indicate that a PHP facility, depending on the radioactive material inventory, may be an exempt, Category 3, or Category 2 facility. The calculated impacts would result in no significant impact to offsite personnel or the environment. Hazardous material assessments indicate that a PHP facility will be a Low Hazard facility having no significant impacts either onsite or offsite to personnel and the environment

  3. Overview of the StratoClim Asian Monsoon Aircraft Campaign: Strategy, Instrumentation and preliminary Results

    Science.gov (United States)

    Stroh, F.

    2017-12-01

    The StratoClim Aircraft Field Campaign employing the high-flying research aircraft M55 Geophysica was carried out from mid July to mid August of 2017 from Kathmandu, Nepal, covering the airspace of Nepal, India, Bangladesh and Myanmar in the frame of the EC FP7 funded StratoClim project (see the Rex. et al. overview in this session). In order to sample the first detailed data set on climate relevant processes of the Asian Summer Monsoon anticyclone a comprehensive chemical and aerosol payload of more than 2 metric tons consisting of 26 different instrumets was flown to altitudes in excess of 20km to measure remote sensing and in-situ data on dynamical, chemical, and micro-chemical processes governing this experimentally underresearched atmospheric domain. An overview of the instrumentation, observation strategies, and preliminary results on open challenges as the horizontal and vertical trace gas and aerosol structures, effects of convective events and the ATAL will be given.

  4. Repository Subsurface Preliminary Fire Hazard Analysis

    International Nuclear Information System (INIS)

    Logan, Richard C.

    2001-01-01

    This fire hazard analysis identifies preliminary design and operations features, fire, and explosion hazards, and provides a reasonable basis to establish the design requirements of fire protection systems during development and emplacement phases of the subsurface repository. This document follows the Technical Work Plan (TWP) (CRWMS M and O 2001c) which was prepared in accordance with AP-2.21Q, ''Quality Determinations and Planning for Scientific, Engineering, and Regulatory Compliance Activities''; Attachment 4 of AP-ESH-008, ''Hazards Analysis System''; and AP-3.11Q, ''Technical Reports''. The objective of this report is to establish the requirements that provide for facility nuclear safety and a proper level of personnel safety and property protection from the effects of fire and the adverse effects of fire-extinguishing agents

  5. Practical considerations in instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Ahmad, N.

    2001-01-01

    Activation analysis is a technique of elemental analysis based on the measurement of characteristics radiation from radionuclides formed directly or indirectly by activation. The activation can be induced by bombarding the material with neutrons or charged particles or gamma rays. This is a well-accepted analytical technique for the determination of composition of complex materials. This technique is also sensitive at trace levels and is almost free from analytical interferences of matrix. It is used for multi-elemental determination in rocks, minerals, alloys, biological materials, geological samples, non-destructive analysis of materials and environmental samples such as water, air particulate matter, plants, soil, sediments and diets. This method is also used for production and measurements of radioisotopes in materials of known composition, for example, when radioactivation is used for nuclear reaction studies, for flux and beam intensity measurements for trace experiments and process quality control. In this article the parameters affecting the sensitivity of instrumental neutron activation analysis are briefly discussed. (author)

  6. Optimization of instrumental activation analysis conditions

    International Nuclear Information System (INIS)

    Guinn, V.; Gavrilas-Guinn, M.

    1993-01-01

    In instrumental neutron activation analysis (INAA) work, a good commonsense rule of thumb is that the opium conditions for the measurement of any induced activity, in a multi-element sample matrix, are an irradiation time, a decay time, and a counting time each approximately equal to the half-life of the radionuclide (if feasible). The INAA Advance Computer Program (APCP) was used to test this rule on ten reference materials. For the 280 radionuclide/material combinations traced through all 14 APCP condition sets, the rule predicted the best set for 67% of them, was off by one set for 31% of them, and was only off by two sets of 2% of them. (author) 6 refs.; 1 fig.; 3 tabs

  7. Plasma brake model for preliminary mission analysis

    Science.gov (United States)

    Orsini, Leonardo; Niccolai, Lorenzo; Mengali, Giovanni; Quarta, Alessandro A.

    2018-03-01

    Plasma brake is an innovative propellantless propulsion system concept that exploits the Coulomb collisions between a charged tether and the ions in the surrounding environment (typically, the ionosphere) to generate an electrostatic force orthogonal to the tether direction. Previous studies on the plasma brake effect have emphasized the existence of a number of different parameters necessary to obtain an accurate description of the propulsive acceleration from a physical viewpoint. The aim of this work is to discuss an analytical model capable of estimating, with the accuracy required by a preliminary mission analysis, the performance of a spacecraft equipped with a plasma brake in a (near-circular) low Earth orbit. The simplified mathematical model is first validated through numerical simulations, and is then used to evaluate the plasma brake performance in some typical mission scenarios, in order to quantify the influence of the system parameters on the mission performance index.

  8. Preliminary Shielding Analysis for HCCB TBM Transport

    Science.gov (United States)

    Miao, Peng; Zhao, Fengchao; Cao, Qixiang; Zhang, Guoshu; Feng, Kaiming

    2015-09-01

    A preliminary shielding analysis on the transport of the Chinese helium cooled ceramic breeder test blanket module (HCCB TBM) from France back to China after being irradiated in ITER is presented in this contribution. Emphasis was placed on irradiation safety during transport. The dose rate calculated by MCNP/4C for the conceptual package design satisfies the relevant dose limits from IAEA that the dose rate 3 m away from the surface of the package containing low specific activity III materials should be less than 10 mSv/h. The change with location and the time evolution of dose rates after shutdown have also been studied. This will be helpful for devising the detailed transport plan of HCCB TBM back to China in the near future. supported by the Major State Basic Research Development Program of China (973 Program) (No. 2013GB108000)

  9. Instrument to collect fogwater for chemical analysis

    OpenAIRE

    Jacob, Daniel J.; Waldman, Jed M.; Haghi, Mehrdad; Hoffmann, Michael R.; Flagan, Richard C.

    1985-01-01

    An instrument is presented which collects large samples of ambient fogwater by impaction of droplets on a screen. The collection efficiency of the instrument is determined as a function of droplet size, and it is shown that fog droplets in the range 3–100-µm diameter are efficiently collected. No significant evaporation or condensation occurs at any stage of the collection process. Field testing indicates that samples collected are representative of the ambient fogwater. The instrument may ea...

  10. Canal preparation with nickel-titanium or stainless steel instruments without the risk of instrument fracture: preliminary observations

    OpenAIRE

    Ghassan Yared

    2015-01-01

    This report introduces a novel technique that allows a safe and predictable canal negotiation, creation of a glide path and canal preparation with reciprocating nickel-titanium or stainless steel engine-driven instruments in canals where the use of rotary and the newly developed reciprocating instruments is contraindicated. In this novel technique, the instruments are used in reciprocating motion with very small angles. Hand files are not used regardless of the complexity of the canal anatomy...

  11. Canal preparation with nickel-titanium or stainless steel instruments without the risk of instrument fracture: preliminary observations

    Directory of Open Access Journals (Sweden)

    Ghassan Yared

    2015-02-01

    Full Text Available This report introduces a novel technique that allows a safe and predictable canal negotiation, creation of a glide path and canal preparation with reciprocating nickel-titanium or stainless steel engine-driven instruments in canals where the use of rotary and the newly developed reciprocating instruments is contraindicated. In this novel technique, the instruments are used in reciprocating motion with very small angles. Hand files are not used regardless of the complexity of the canal anatomy. It also allows achieving predictable results in canal negotiation and glide path creation in challenging canals without the risk of instrument fracture.

  12. ProRisk : risk analysis instrument : developed for William properties

    NARCIS (Netherlands)

    van Doorn, W.H.W.; Egeberg, Ingrid; Hendrickx, Kristoff; Kahramaner, Y.; Masseur, B.; Waijers, Koen; Weglicka, K.A.

    2005-01-01

    This report presents a Risk Analysis Instrument developed for William Properties. Based on the analysis, it appears that the practice of Risk Analysis exists within the organization, yet rather implicit. The Risk Analysis Instrument comes with a package of four components: an activity diagram, a

  13. Spectroscopy: Developments in instrumentation and analysis

    Directory of Open Access Journals (Sweden)

    Dardenne, Pierre

    2002-03-01

    Full Text Available This review presents the characteristics, advantages, limits and potential of three spectroscopic techniques: near-infrared spectroscopy (NIR, mid-infrared spectroscopy (MIR and Raman spectroscopy. The theoretical aspects related with these techniques, the information that can supplied and the main features of the instrumentation are presented and briefly discussed. The last part of the review concerns the application of the spectroscopy to food analysis, with special emphasis on the lipid analysis. The illustrations and examples have been chosen to demonstrate the importance of spectroscopic techniques both in process (on-line control and in laboratories for the analysis of major or minor compounds.Este artículo de revisión presenta las características, ventajas, límites y potencial de tres técnicas espectroscópicas: las espectroscopias del infrarrojo cercano, del medio infrarrojo y Raman. Se presentan, y discuten brevemente, los aspectos teóricos relacionados con estas técnicas, la información que pueden suministrar, y las principales características de la instrumentación. La última parte de la revisión esta dedicada a las aplicaciones de la espectroscopia en análisis de alimentos, con especial énfasis en análisis de lípidos. La ilustraciones y los ejemplos se han elegido para demostrar la importancia de las técnicas espectroscópicas en los procesos en-línea y en los laboratorios en el análisis de componentes mayoritarios y minoritarios.

  14. Instrumental neutron activation analysis in environmental research

    International Nuclear Information System (INIS)

    Bruin, M. de.

    1985-01-01

    The main characteristics of instrumental neutron activation analysis (INAA),relevant for environmental research and monitoring, was reviewed and discussed-sensitivity, suitable for detection of many toxic elements, the low risks of contamination of element loss, lack of matrix effects, lack of light element interference except for 24 Na, capability for multi-element determination, comparatively low costs. A detailed description of the IRI analysis system for routine INAA is given. The system is based on the single comparator method of standartization to take full advantage of multi-element without preparation and use the trace element standards. Zinc was used as mono element standard, the element concentrations are calculated on the basis of 65 Zn and 69m Zn-activities. The irradiations were carried out in a thermal neutron flux of 1.10 13 n/cm 2 .s. The gamma spectra is converted into element concentrations using a set of dedicated software, performing the following functions: spectrum analysis and interpretation, comparison and combination of the intermediate results from different decay times, generation of the final report, bookkeeping of the results obtained. The main applications of the INAA system mentioned are: identification of sources of heavy metal air pollution using air filters or biological indicators such as mosses, lichens, toe-nails, bird feathers, molusks and waterplants; and study of the uptake and translocation of heavy element in plants. Special attention was paid to mathematical techniques for a reliable interpretation of the element concentration patterns observed in sets of lichen samples. Future developments in INAA in environmental science are briefly mentioned

  15. Preliminary results of aerosols' properties studied with EPF measurements from the SPICAM/UV instrument

    Science.gov (United States)

    Willame, Yannick; Carine Vandaele, Ann; Depiesse, Cedric; Gillotay, Didier; Kochenova, Svetlana; Montmessin, Franck

    2013-04-01

    Aerosols on Mars have an important impact on the radiative transfer properties of its atmosphere. Today their spectral properties and therefore their interaction with UV radiation are only poorly known. Improving the radiative transfer modeling requires a better knowledge of their characteristics, in particular of their opacity, phase function and single scattering albedo. Part of such information can be accessed by using EPF observations. The SPICAM instrument on board of the Mars-Express satellite is a 2 channel spectrometer. One channel operates in the ultraviolet (118-320 nm) and the second one in the infrared (1.0-1.7μm). SPICAM has been orbiting around the red planet since 2003 and has thus provided a large set of data. The instrument is capable of measuring under different geometries (nadir, limb, occultation) and one of them, called EPF (Emission Phase Function), can be a tool to study aerosols' properties. We have developed a new retrieval algorithm for nadir measurements based on the radiative transfer model LIDORT. This new code performs simulations of spectra taking into account gas absorption, surface reflection and scattering by aerosols and gases. The retrieval method, based on the optimal estimation, allows us up to now to deduce the ozone column density, the aerosols' optical depth and the surface albedo (with fixed wavelength dependencies). We are developing our model further in order to better study the aerosols' characteristics using EPF observations, which consist in looking at the same point on the planet while the satellite moves along the orbit. As the attempt to study all the aerosols' properties simultaneously was not convincing, we started studying their opacity and the influence of its altitude distribution with the other characteristics fixed. We will present preliminary results of our study on aerosols' properties using EPF data from SPICAM.

  16. Activation analysis by filtered neutrons. Preliminary investigation

    International Nuclear Information System (INIS)

    Skarnemark, G.; Rodinson, T.; Skaalberg, M.; Tokay, R.K.

    1986-01-01

    In order to investigate if measuring sensibility and precision by epithermal neutron activation analysis may be improved, different types of geological and biologic test samples were radiated. The test samples were enclosed in an extra filter of tungsten or sodium in order to reduce the flux of those neutrons that otherwise would induce interfering activity in the sample. The geological test samples consist of granites containing lanthanides which had been crushed in tung- sten carbide grinder. Normally such test samples show a interferins 1 87W-activity. By use of a tungsten filter the activity was reduced by up to 60%, which resulted in a considerable improvement of sensibility and precision of the measurement. The biologic test samples consisted of evaporated urine from patients treated with the cell poison cis-platinol. A reliable method to measure the platinum content has not existed so far. This method, however, enables platinum contents as low as about 0.1 ppm to be determined which is quite adequate. To sum up this preliminary study has demonstrated that activation analysis using filtered neutrons, correctly applied, is a satisfactory method of reducing interferences without complicated and time-consuming chemical separation procedures. (O.S.)

  17. CRITICAL ANALYSIS OF THEIR RISK FINANCIAL INSTRUMENTS

    Directory of Open Access Journals (Sweden)

    CARUNTU GENU ALEXANDRU

    2013-12-01

    Full Text Available In the last decade, accounting for financial instruments has experienced a revolution, following the publication of accounting rules on recognition and measurement of these instruments saddle. Need to develop standards for financial instruments appeared on the background of explosion using derivatives and the markets in which they are traded, and as a result of numerous financial scandals that rocked developed countries in the last decade. These were based, among other causes, improper use of derivatives and hiding their disastrous effects of poor management by keeping them off balance and failure to provide related information in the notes of the financial statements.

  18. Instrument to collect fogwater for chemical analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jacob, D.J.; Waldman, J.M.; Haghi, M.; Hoffmann, M.R.; Flagan, R.C.

    1985-06-01

    An instrument is presented which collects large samples of ambient fogwater by impaction of droplets on a screen. The collection efficiency of the instrument is determined as a function of droplet size, and it is shown that fog droplets in the range 3--100-..mu..m diameter are efficiently collected. No significant evaporation or condensation occurs at any stage of the collection process. Field testing indicates that samples collected are representative of the ambient fogwater. The instrument may easily be automated, and is suitable for use in routine air quality monitoring programs.

  19. Instrument to collect fogwater for chemical analysis

    Science.gov (United States)

    Jacob, Daniel J.; Waldman, Jed M.; Haghi, Mehrdad; Hoffmann, Michael R.; Flagan, Richard C.

    1985-06-01

    An instrument is presented which collects large samples of ambient fogwater by impaction of droplets on a screen. The collection efficiency of the instrument is determined as a function of droplet size, and it is shown that fog droplets in the range 3-100-μm diameter are efficiently collected. No significant evaporation or condensation occurs at any stage of the collection process. Field testing indicates that samples collected are representative of the ambient fogwater. The instrument may easily be automated, and is suitable for use in routine air quality monitoring programs.

  20. Analysis the fatigue using pro taper rotary instruments durin instrumentation of extrated mandibular premolars. SEM observation.

    OpenAIRE

    Siragusa, Martha; Racciatti, Gabriela; García, María

    2007-01-01

    Recibido: Marzo 2007 Aceptado: Julio 2007 Siragusa, Martha; Racciatti, Gabriela y García, María. Analysis the fatigue using pro taper rotary instruments durin instrumentation of extrated mandibular premolars. SEM observation. Electronic Journal of Endodontics Rosario [Online], Volumen 2 Número 13. [octubre 2007]. http://www.endojournal.com.ar/journal/index.php/ejer/article/view/44. ISSN 1666-6143.

  1. Teaching Students to Be Instrumental in Analysis: Peer-Led Team Learning in the Instrumental Laboratory

    Science.gov (United States)

    Williams, Jacob L.; Miller, Martin E.; Avitabile, Brianna C.; Burrow, Dillon L.; Schmittou, Allison N.; Mann, Meagan K.; Hiatt, Leslie A.

    2017-01-01

    Many instrumental analysis students develop limited skills as the course rushes through different instruments to ensure familiarity with as many methodologies as possible. This broad coverage comes at the expense of superficiality of learning and a lack of student confidence and engagement. To mitigate these issues, a peer-led team learning model…

  2. Preliminary hazard analysis using sequence tree method

    International Nuclear Information System (INIS)

    Huang Huiwen; Shih Chunkuan; Hung Hungchih; Chen Minghuei; Yih Swu; Lin Jiinming

    2007-01-01

    A system level PHA using sequence tree method was developed to perform Safety Related digital I and C system SSA. The conventional PHA is a brainstorming session among experts on various portions of the system to identify hazards through discussions. However, this conventional PHA is not a systematic technique, the analysis results strongly depend on the experts' subjective opinions. The analysis quality cannot be appropriately controlled. Thereby, this research developed a system level sequence tree based PHA, which can clarify the relationship among the major digital I and C systems. Two major phases are included in this sequence tree based technique. The first phase uses a table to analyze each event in SAR Chapter 15 for a specific safety related I and C system, such as RPS. The second phase uses sequence tree to recognize what I and C systems are involved in the event, how the safety related systems work, and how the backup systems can be activated to mitigate the consequence if the primary safety systems fail. In the sequence tree, the defense-in-depth echelons, including Control echelon, Reactor trip echelon, ESFAS echelon, and Indication and display echelon, are arranged to construct the sequence tree structure. All the related I and C systems, include digital system and the analog back-up systems are allocated in their specific echelon. By this system centric sequence tree based analysis, not only preliminary hazard can be identified systematically, the vulnerability of the nuclear power plant can also be recognized. Therefore, an effective simplified D3 evaluation can be performed as well. (author)

  3. Analysis of atmospheric particulate samples via instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Greenberg, R.R.

    1990-01-01

    Instrumental neutron activation analysis (INAA) is a powerful analytical technique for the elemental characterization of atmospheric particulate samples. It is a true multielement technique with adequate sensitivity to determine 30 to 40 elements in a sample of atmospheric particulate material. Its nondestructive nature allows sample reanalysis by the same or a different analytical technique. In this paper as an example of the applicability of INAA to the study of atmospheric particulate material, a study of the emissions from municipal incinerators is described

  4. The Pavlovian analysis of instrumental conditioning.

    Science.gov (United States)

    Gormezano, I; Tait, R W

    1976-01-01

    An account was given of the development within the Russian literature of a uniprocess formulation of classical and instrumental conditioning, known as the bidirectional conditioning hypothesis. The hypothesis purports to offer a single set of Pavlovian principles to account for both paradigms, based upon a neural model which assumes that bidirectional (forward and backward) connections are formed in both calssical and instrumental conditioning situations. In instrumental conditioning, the bidirectional connections are hypothesized to be simply more complex than those in classical conditioning, and any differences in empirical functions are presumed to lie not in difference in mechanism, but in the strength of the forward and backward connections. Although bidirectional connections are assumed to develop in instrumental conditioning, the experimental investigation of the bidirectional conditioning hypothesis has been essentially restricted to the classical conditioning operations of pairing two CSs (sensory preconditioning training), a US followed by a CS (backward conditioning training) and two USs. However, the paradigm involving the pairing of two USs, because of theoretical and analytical considerations, is the one most commonly employed by Russian investigators. The results of an initial experiment involving the pairing of two USs, and reference to the results of a more extensive investigation, leads us to tentatively question the validity of the bidirectional conditioning account of instrumental conditioning.

  5. Cross-instrument Analysis Correlation Software

    Energy Technology Data Exchange (ETDEWEB)

    2017-06-28

    This program has been designed to assist with the tracking of a sample from one analytical instrument to another such as SEM, microscopes, micro x-ray diffraction and other instruments where particular positions/locations on the sample are examined, photographed, etc. The software is designed to easily enter the position of fiducials and locations of interest such that in a future session in the same of different instrument the positions of interest can be re-found through using the known location fiducials in the current and reference session to transform the point into the current sessions coordinate system. The software is dialog box driven guiding the user through the necessary data entry and program choices. Information is stored in a series of text based extensible markup language (XML) files.

  6. Preliminary Analysis and Selection of Mooring Solution Candidates

    DEFF Research Database (Denmark)

    Thomsen, Jonas Bjerg; Delaney, Martin

    This report covers a preliminary analysis of mooring solutions candidates for four large floating wave energy converters. The work is part of the EUDP project “Mooring Solutions for Large Wave Energy Converters” and is the outcome of "Work Package 3: Preliminary Analysis". The report further...... compose the "Milestone 4: Report on results of preliminary analysis and selection of final candidates. The report is produced by Aalborg University with input from the partner WECs Floating Power Plant, KNSwing, LEANCON and Wave Dragon. Tension Technology International (TTI) has provided a significant...

  7. Setting up a new CZO in the Ganga basin: instrumentation, stakeholder engagement and preliminary observations

    Science.gov (United States)

    Gupta, S.; Tripathi, S.; Sinha, R.; Karumanchi, S. H.; Paul, D.; Tripathi, S. N.; Sen, I. S.; Dash, S. K.

    2017-12-01

    The Ganga plains represent the abode of more than 400 million people and a region of severe anthropogenic disturbance to natural processes. Changing agricultural practices, inefficient use of water, contamination of groundwater systems, and decrease in soil fertility are some of the issues that have affected the long-term resilience of hydrological processes. The quantification of these processes demands a network of hydro-meteorological instrumentation, low-cost sensors, continuous engagement of stakeholders and real time data transmission at a fine interval. We have therefore set up a Critical Zone Observatory (CZO) in a small watershed (35km2) that forms an intensively managed rural landscape consisting of 92% of agricultural land in the Pandu River Basin (a small tributary of the Ganga River). Apart from setting up a hydro-meteorological observatory, the major science questions we want to address relate to development of water balance model, understanding the soil-water interaction and estimation of nutrient fluxes in the watershed. This observatory currently has various types of sensors that are divided into three categories: (a) spatially not dense but temporally fine data, (b) spatially dense but temporally not fine data and(c) spatially dense and temporally fine data. The first category represent high-cost sensors namely automatic weather stations that are deployed at two locations and provide data at 15-minute interval. The second category includes portable soil moisture, discharge and groundwater level at weekly/ biweekly interval. The third category comprises low-cost sensors including automatic surface and groundwater level sensors installed on open wells to monitor the continuous fluctuation of water level at every 15 minutes. In addition to involving the local communities in data collection (e.g. manual rainfall measurement, water and soil sampling), this CZO also aims to provide relevant information to them for improving their sustainability. The

  8. Quality charter. Instrumentation of solar and wind powered electricity generating systems in isolated sites. A preliminary functional analysis; Charte de qualite. Instrumentation des systemes de production d`electricite en sites isoles a base d`energie photovoltaique et eolienne. Premiere analyse fonctionnelle

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, A.; Mauras, P.; Jacquin, P.

    1996-10-01

    This document is intended to become one of the Quality Charter documents. It presents the functions which must be provided by the instrumentation systems designed for use in solar and wind powered electricity generating systems in isolated designed for use in solar and wind powered electricity generating systems in isolated sites and should be viewed in close conjunction with the `Typology` and `Energy Management` documents covering the same systems of electricity generation in isolated sites; Together, these documents provide the definition of a range of eight energy management systems and four instrumentation systems specially adapted to the different types of facilities and requirements. (authors)

  9. Preliminary safety analysis of the Gorleben site

    International Nuclear Information System (INIS)

    Bracke, G.; Fischer-Appelt, K.

    2014-01-01

    The safety requirements governing the final disposal of heat-generating radioactive waste in Germany were implemented by the Federal Ministry of Environment, Natural Conservation and Nuclear Safety (BMU) in 2010. The Ministry considers as a fundamental objective the protection of man and the environment against the hazards of radioactive waste. Unreasonable burdens and obligation for future generations shall be avoided. The main safety principles are concentration and inclusion of radioactive and other pollutants in a containment-providing rock zone. Any release of radioactive nuclides may increase the risk for men and the environment only negligibly compared to natural radiation exposure. No intervention or maintenance work shall be necessary in the post-closure phase. Retrieval/recovery of the waste shall be possible up to 500 years after closure. The Gorleben salt dome has been discussed since the 1970's as a possible repository site for heat-generating radioactive waste in Germany. The objective of the project preliminary safety analysis of the Gorleben site (VSG) was to assess if repository concepts at the Gorleben site or other sites with a comparable geology could comply with these requirements based on currently available knowledge (Fischer-Appelt, 2013; Bracke, 2013). In addition to this it was assessed if methodological approaches can be used for a future site selection procedure and which technological and conceptual considerations can be transferred to other geological situations. The objective included the compilation and review of the available exploration data of the Gorleben site and on disposal in salt rock, the development of repository designs, and the identification of the needs for future R and D work and further site investigations. (authors)

  10. Comparing surgical trays with redundant instruments with trays with reduced instruments: a cost analysis.

    Science.gov (United States)

    John-Baptiste, A; Sowerby, L J; Chin, C J; Martin, J; Rotenberg, B W

    2016-01-01

    When prearranged standard surgical trays contain instruments that are repeatedly unused, the redundancy can result in unnecessary health care costs. Our objective was to estimate potential savings by performing an economic evaluation comparing the cost of surgical trays with redundant instruments with surgical trays with reduced instruments ("reduced trays"). We performed a cost-analysis from the hospital perspective over a 1-year period. Using a mathematical model, we compared the direct costs of trays containing redundant instruments to reduced trays for 5 otolaryngology procedures. We incorporated data from several sources including local hospital data on surgical volume, the number of instruments on redundant and reduced trays, wages of personnel and time required to pack instruments. From the literature, we incorporated instrument depreciation costs and the time required to decontaminate an instrument. We performed 1-way sensitivity analyses on all variables, including surgical volume. Costs were estimated in 2013 Canadian dollars. The cost of redundant trays was $21 806 and the cost of reduced trays was $8803, for a 1-year cost saving of $13 003. In sensitivity analyses, cost savings ranged from $3262 to $21 395, based on the surgical volume at the institution. Variation in surgical volume resulted in a wider range of estimates, with a minimum of $3253 for low-volume to a maximum of $52 012 for high-volume institutions. Our study suggests moderate savings may be achieved by reducing surgical tray redundancy and, if applied to other surgical specialties, may result in savings to Canadian health care systems.

  11. Analysis of cryptocurrencies as standard financial instruments

    OpenAIRE

    Bartoš, Jakub

    2014-01-01

    This paper analyzes cryptocurrencies as financial instruments. Firstly, we introduced the main features of cryptocurrencies and summarized the brief history. We found out that price of the most famous cryptocurrency Bitcoin follows the hypothesis of efficient markets and it immediately react on publicly announce information. Furthermore, Bitcoin can be seen as standard economic good that is priced by interaction of supply and demand on the market. These factors can be driven by macro financia...

  12. The Scrap Tire Problem: A Preliminary Economic Analysis (1985)

    Science.gov (United States)

    The purpose of the study was to conduct a preliminary economic analysis of the social benefits of EPA action to require more appropriate disposal of scrap tires versus the social costs of such an action.

  13. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  14. Original Article PRELIMINARY BIOAUTOGRAPHIC ANALYSIS OF ...

    African Journals Online (AJOL)

    Sierra Leone 2Department of Pharmaceutical Chemistry, Faculty of Pharmacy, ... the seeds are used in the treatment of skin infections. ... Screening with DPPH showed prominent antioxidant spots on silica at Rf 0.8, 0.5, 0.4 .... underpins conditions like rheumatoid arthritis, ..... As a follow-up to the preliminary TLC studies.

  15. Power calculator for instrumental variable analysis in pharmacoepidemiology.

    Science.gov (United States)

    Walker, Venexia M; Davies, Neil M; Windmeijer, Frank; Burgess, Stephen; Martin, Richard M

    2017-10-01

    Instrumental variable analysis, for example with physicians' prescribing preferences as an instrument for medications issued in primary care, is an increasingly popular method in the field of pharmacoepidemiology. Existing power calculators for studies using instrumental variable analysis, such as Mendelian randomization power calculators, do not allow for the structure of research questions in this field. This is because the analysis in pharmacoepidemiology will typically have stronger instruments and detect larger causal effects than in other fields. Consequently, there is a need for dedicated power calculators for pharmacoepidemiological research. The formula for calculating the power of a study using instrumental variable analysis in the context of pharmacoepidemiology is derived before being validated by a simulation study. The formula is applicable for studies using a single binary instrument to analyse the causal effect of a binary exposure on a continuous outcome. An online calculator, as well as packages in both R and Stata, are provided for the implementation of the formula by others. The statistical power of instrumental variable analysis in pharmacoepidemiological studies to detect a clinically meaningful treatment effect is an important consideration. Research questions in this field have distinct structures that must be accounted for when calculating power. The formula presented differs from existing instrumental variable power formulae due to its parametrization, which is designed specifically for ease of use by pharmacoepidemiologists. © The Author 2017. Published by Oxford University Press on behalf of the International Epidemiological Association

  16. Preliminary analysis of a 1:4 scale prestressed concrete containment vessel model

    International Nuclear Information System (INIS)

    Dameron, R.A.; Rashid, Y.R.; Luk, V.K.; Hessheimer, M.F.

    1997-01-01

    Sandia National Laboratories is conducting a research program to investigate the integrity of nuclear containment structures. As part of the program Sandia will construct an instrumented 1:4 scale model of a prestressed concrete containment vessel (PCCV) for pressurized water reactors (PWR), which will be pressure tested up to its ultimate capacity. One of the key program objectives is to develop validated methods to predict the structural performance of containment vessels when subjected to beyond design basis loadings. Analytical prediction of structural performance requires a stepwise, systematic approach that addresses all potential failure modes. The analysis effort includes two and three-dimensional nonlinear finite element analyses of the PCCV test model to evaluate its structural performance under very high internal pressurization. Such analyses have been performed using the nonlinear concrete constitutive model, ANACAP-U, in conjunction with the ABAQUS general purpose finite element code. The analysis effort is carried out in three phases: preliminary analysis; pretest prediction; and post-test data interpretation and analysis evaluation. The preliminary analysis phase serves to provide instrumentation support and identify candidate failure modes. The associated tasks include the preliminary prediction of failure pressure and probable failure locations and the development of models to be used in the detailed failure analyses. This paper describes the modeling approaches and some of the results obtained in the first phase of the analysis effort

  17. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2000-01-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised

  18. Analysis and Synthesis of Musical Instrument Sounds

    Science.gov (United States)

    Beauchamp, James W.

    For synthesizing a wide variety of musical sounds, it is important to understand which acoustic properties of musical instrument sounds are related to specific perceptual features. Some properties are obvious: Amplitude and fundamental frequency easily control loudness and pitch. Other perceptual features are related to sound spectra and how they vary with time. For example, tonal "brightness" is strongly connected to the centroid or tilt of a spectrum. "Attack impact" (sometimes called "bite" or "attack sharpness") is strongly connected to spectral features during the first 20-100 ms of sound, as well as the rise time of the sound. Tonal "warmth" is connected to spectral features such as "incoherence" or "inharmonicity."

  19. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  20. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  1. Professionalism Mini-Evaluation Exercise in Finland: A preliminary investigation introducing the Finnish version of the P-MEX instrument.

    Science.gov (United States)

    Karukivi, Max; Kortekangas-Savolainen, Outi; Saxén, Ulla; Haapasalo-Pesu, Kirsi-Maria

    2015-10-01

    Teaching medical professionalism is increasingly acknowledged as an important aspect of medical education. The Professionalism Mini-Evaluation Exercise (P-MEX) is an assessment tool for evaluating medical professionalism, but no studies using it as a self-assessment instrument have been reported. This paper reports on a preliminary investigation of the Finnish version of the P-MEX instrument as an assessment and self-assessment measure. The sample in the present cross-sectional study comprised all 23 medical students and recent graduates (15 females and 8 males) participating in a summer school of psychiatry program in 2014. The two-month program combines clinical work with multifaceted teaching and intensive tutoring. At the end of the program, the participants' medical professionalism was assessed by the tutors and other members of the work community as well as the students themselves using the Finnish version of the P-MEX instrument. The P-MEX scores were compared, using the Friedman test. The mean values and SD for the P-MEX assessments were as follows: tutor assessment 3.26±0.21, work community assessment 3.32±0.26 and self-assessment 3.01±0.07. No significant gender differences were observed. The tutor and work community assessments were significantly correlated (r=0.573, p=0.040), but the self-assessment scores did not correlate with either of the other assessments. Overall, the students evaluated their skills significantly poorer in comparison to the other assessments. Although the small sample size limits the generalization of these preliminary results, the Finnish version of the P-MEX instrument appears to be a feasible measure of medical professionalism. The instrument can also be used as a self-assessment instrument, but subjective evaluations should be complemented with external assessments or feedback in order to take individual and cultural aspects into account.

  2. Surface Properties of TNOs: Preliminary Statistical Analysis

    Science.gov (United States)

    Antonieta Barucci, Maria; Fornasier, S.; Alvarez-Cantal, A.; de Bergh, C.; Merlin, F.; DeMeo, F.; Dumas, C.

    2009-09-01

    An overview of the surface properties based on the last results obtained during the Large Program performed at ESO-VLT (2007-2008) will be presented. Simultaneous high quality visible and near-infrared spectroscopy and photometry have been carried out on 40 objects with various dynamical properties, using FORS1 (V), ISAAC (J) and SINFONI (H+K bands) mounted respectively at UT2, UT1 and UT4 VLT-ESO telescopes (Cerro Paranal, Chile). For spectroscopy we computed the spectral slope for each object and searched for possible rotational inhomogeneities. A few objects show features in their visible spectra such as Eris, whose spectral bands are displaced with respect to pure methane-ice. We identify new faint absorption features on 10199 Chariklo and 42355 Typhon, possibly due to the presence of aqueous altered materials. The H+K band spectroscopy was performed with the new instrument SINFONI which is a 3D integral field spectrometer. While some objects show no diagnostic spectral bands, others reveal surface deposits of ices of H2O, CH3OH, CH4, and N2. To investigate the surface properties of these bodies, a radiative transfer model has been applied to interpret the entire 0.4-2.4 micron spectral region. The diversity of the spectra suggests that these objects represent a substantial range of bulk compositions. These different surface compositions can be diagnostic of original compositional diversity, interior source and/or different evolution with different physical processes affecting the surfaces. A statistical analysis is in progress to investigate the correlation of the TNOs’ surface properties with size and dynamical properties.

  3. The role of domain analysis in prediction instrument development

    NARCIS (Netherlands)

    van der Spoel, Sjoerd; Amrit, Chintan Amrit; van Hillegersberg, Jos

    2016-01-01

    In order to develop prediction instruments that have sufficient predictive power, it is essential to understand the specific domain the prediction instrument is developed for. This domain analysis is especially important for domains where human behavior, politics, or other soft factors play a role.

  4. Life cycle analysis in preliminary design stages

    OpenAIRE

    Agudelo , Lina-Maria; Mejía-Gutiérrez , Ricardo; Nadeau , Jean-Pierre; PAILHES , Jérôme

    2014-01-01

    International audience; In a design process the product is decomposed into systems along the disciplinary lines. Each stage has its own goals and constraints that must be satisfied and has control over a subset of design variables that describe the overall system. When using different tools to initiate a product life cycle, including the environment and impacts, its noticeable that there is a gap in tools that linked the stages of preliminary design and the stages of materialization. Differen...

  5. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  6. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  7. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2000-07-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised.

  8. Instrumental Neutron Activation Analysis and Multivariate Statistics for Pottery Provenance

    Science.gov (United States)

    Glascock, M. D.; Neff, H.; Vaughn, K. J.

    2004-06-01

    The application of instrumental neutron activation analysis and multivariate statistics to archaeological studies of ceramics and clays is described. A small pottery data set from the Nasca culture in southern Peru is presented for illustration.

  9. Instrumental Neutron Activation Analysis and Multivariate Statistics for Pottery Provenance

    International Nuclear Information System (INIS)

    Glascock, M. D.; Neff, H.; Vaughn, K. J.

    2004-01-01

    The application of instrumental neutron activation analysis and multivariate statistics to archaeological studies of ceramics and clays is described. A small pottery data set from the Nasca culture in southern Peru is presented for illustration.

  10. Instrumental Neutron Activation Analysis and Multivariate Statistics for Pottery Provenance

    Energy Technology Data Exchange (ETDEWEB)

    Glascock, M. D.; Neff, H. [University of Missouri, Research Reactor Center (United States); Vaughn, K. J. [Pacific Lutheran University, Department of Anthropology (United States)

    2004-06-15

    The application of instrumental neutron activation analysis and multivariate statistics to archaeological studies of ceramics and clays is described. A small pottery data set from the Nasca culture in southern Peru is presented for illustration.

  11. Review of Preliminary Analysis Techniques for Tension Structures.

    Science.gov (United States)

    1984-02-01

    however,a linear dinamic analysis can be conducted for purposes of preliminary design, relative to the static configuration. It is noted that the amount of...16 Chapter 3. PRELIMINARY DESIGN OF TENSION STRUCTURES . . .. .. .. .... 22 S.3.1 Cable Systems . . . . . . . . . . . . .. .. .. .... 23...3.1.1 Singly-Connected Segments. .. .... ... 24 3.1.2 Multiply-Connected Segments . . .. .. .. .. 27 3.1.3 Linearized Dynamics of Cable Systems . . . . 29

  12. Biomedical instruments versus toys:a preliminary comparison of force platforms and the nintendo wii balance board - biomed 2011.

    Science.gov (United States)

    Pagnacco, Guido; Oggero, Elena; Wright, Cameron H G

    2011-01-01

    Biomedical sciences rely heavily on devices to acquire and analyze the physiological data needed to understand and model the biological processes of humans and animals. Therefore, the results of the investigations, clinical or academic, depend heavily on the instrumentation used. Unfortunately, all too often the users do not understand their instruments and end up compromising the results of their investigations by choosing an inadequate instrument or by not using it appropriately. One field where this is particularly apparent is posturography: the misconceptions about instruments are so widespread and deep that just recently there have been articles published in scientific journals suggesting the use of a “toy”, the Nintendo Wii Balance Board, instead of instrument grade force platform to acquire posturographic data. Characterizing the tools used for research becomes the first and probably the most important step in producing sound research and clinical results, and in the case of posturographic force platforms and the Nintendo Wii Balance Board a simple experimental setup can be used to find their characteristics. Furthermore, based on the preliminary results of this investigation, a mathematical formula can be used to predict the behavior of a posturographic tool, once its noise characteristics and “dead weight” response are known.

  13. Development of intelligent system for a thermal analysis instrument

    International Nuclear Information System (INIS)

    Xu Xiaoli; Wu Guoxin; Shi Yongchao

    2005-01-01

    The key techniques for the intelligent analysis instrument developed are proposed. Based on the technique of virtual instrumentation, the intelligent PID control algorithm to control the temperature of thermal analysis instrument is described. The dynamic character and the robust performance of traditional PID controls are improved through the dynamic gain factor, temperature rate change factor, the forecast factor, and the temperature correction factor is introduced. Using the graphic development environment of LabVIEW, the design of system modularization and the graphic display are implemented. By means of multiple mathematical modules, intelligent data processing is realized

  14. Instrumental neutron activation analysis of brewer's yeast

    International Nuclear Information System (INIS)

    Bergerioux, C.; Zikovsky, L.

    1978-01-01

    Instrumental neutron activation was used for the determination of 23 trace and minor elements in 4 different samples of brewer's yeast. Detection limits vary from 2 ppb to 100 ppm. The following average concentrations were found (ppm, dry weight): Al 597, Br 0.36, Cl 1473, Co 0.21, Cu 19, Fe 285, K 16400, Mg 1355, Mn 8.4, Na 2330, Rb 19, Sb 0.053, Se 1.2, V 2.2 and Zn 80. NBS standard 1569 was also analyzed and the following concentrations (in ppm) were measured: Al 2300, Br 0.65, Ce 0.23, Cl 460, Co 0.26, Cr 2.12, Cu 11, Fe 707, Gd 7.1, Hf 0.13, K 15500, Mg 1780, Mn 7, Na 510, Rb 16, Sb 0.075, Sc 0.18, Se 0.92, Th 3.7, Ti 38, U 0.49, V 4.1 and Zn 70. (author)

  15. Conference on instrumental activation analysis IAA 85

    International Nuclear Information System (INIS)

    1985-05-01

    The conference heard 23 papers dealing with the application of activation analysis in environmental control, the preparation of calibration standards, gamma spectroscopy, data processing and with the control of the purity of radiopharmaceuticals. (J.P.)

  16. An equipment complex for instrumental elementary analysis

    International Nuclear Information System (INIS)

    Borisov, G.I.; Komkov, M.M.; Kuz'michev, V.A.; Leonov, V.F.; Tarasov, Y.F.

    1986-01-01

    The competitiveness of elementary analysis on a research reactor depends, in many respects, on the provision of equipment which would permit the realization of the advantages of the analytical method. This paper describes the IR-8 reactor at the I.V. Kurchatov Institute of Atomic energy. In the design of the complex considerable attention was focused on automation and the radiation safety of the operations, which is of particular importance in the light of the large volumes of analysis

  17. Evaluating Preschool Children Knowledge about Healthy Lifestyle: Preliminary Examination of the Healthy Lifestyle Evaluation Instrument

    Science.gov (United States)

    Grammatikopoulos, Vasilis; Konstantinidou, Elisavet; Tsigilis, Nikolaos; Zachopoulou, Evridiki; Tsangaridou, Niki; Liukkonen, Jarmo

    2008-01-01

    The aim of this study was to develop an instrument to evaluate the knowledge of preschool children about healthy lifestyle behavior. The innovation was that the instrument was designed to get direct evidence about healthy lifestyle from children aged 4-6 years old. Usually, children knowledge is estimated indirectly (parents, teachers), but the…

  18. Instrumental Neutron Activation Analysis for Human Hair

    International Nuclear Information System (INIS)

    Ratanatongchai, W.; Dharmvanij, W; Chongkum, S.

    1998-01-01

    Hair samples from students aged between 7 to 22 years old were analysed by neutron activation analysis at nuclear research reactor TRR-1.M1. From qualitative analysis of short-lived isotopes, A1, V, Ca, I, Cl, Mn, and Na were found. The quantity of those elements can be classified into three groups. The first group is A1, Ca, Na and Cl with variance less than 10%. The second group is V and I with variance between 10% to 50% and the third group, Mn, two samples have concentration about 12 times higher than the others

  19. Conference on instrumental activation analysis IAA 86

    International Nuclear Information System (INIS)

    Vobecky, M.; Obrusnik, I.

    1986-04-01

    Thirty five papers were presented at the conference held in Klucenice, Czechoslovakia from May 4 to 8, 1986. The abstracts of all papers are printed in the proceedings. The conference discussed the following problem areas: the application of activation analysis in determining elements in ores, tectites, fungi, the thyroid, the primary circuit coolant, semiconductor materials; the application of nuclear reaction analysis in determining elements in rubber and coal; the application of tracer techniques in metallurgy; the description of alpha and gamma spectrometric systems and their testing; the use of microcomputers for data processing, and the description of programs. (J.P.)

  20. Detection Limit of Smectite by Chemin IV Laboratory Instrument: Preliminary Implications for Chemin on the Mars Science Laboratory Mission

    Science.gov (United States)

    Archilles, Cherie; Ming, D. W.; Morris, R. V.; Blake, D. F.

    2011-01-01

    The CheMin instrument on the Mars Science Laboratory (MSL) is an miniature X-ray diffraction (XRD) and X-ray fluorescence (XRF) instrument capable of detecting the mineralogical and elemental compositions of rocks, outcrops and soils on the surface of Mars. CheMin uses a microfocus-source Co X-ray tube, a transmission sample cell, and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D XRD patterns and energy-dispersive X-ray histograms from powdered samples. CRISM and OMEGA have identified the presence of phyllosilicates at several locations on Mars including the four candidate MSL landing sites. The objective of this study was to conduct preliminary studies to determine the CheMin detection limit of smectite in a smectite/olivine mixed mineral system.

  1. Instruments

    International Nuclear Information System (INIS)

    Buehrer, W.

    1996-01-01

    The present paper mediates a basic knowledge of the most commonly used experimental techniques. We discuss the principles and concepts necessary to understand what one is doing if one performs an experiment on a certain instrument. (author) 29 figs., 1 tab., refs

  2. Financial analysis as a financial management instrument

    Directory of Open Access Journals (Sweden)

    Stehlíková Beáta

    2001-12-01

    Full Text Available The financial market is one of the elements of the market-oriented economy. The financial analysis is a fundamental element of the financial controlling business. The purpose of this article is to inform briefly about horizontal and vertical financial statements analysis as the source of competitive advantage of the firm. The article is divided into two parts. First describes financial analysis and financial statements generally. Second, it presents a practical contribution of the horizontal and vertical financial statements analysis at the controlled businesses as financial management tools, which identify the financial position, market behaviour, correlations between the net profit and the prohibitively cost and operating profit, the financial activities profit, the income tax etc.Business, which the analysed firm operates in asks a provable claim on the high value of fixed assets. The capital composition of the firm is call to typify for the state-owned enterprise that was transformed to private joint-stock companies. Analysis is specially pleading for the needs considering the price of the borrowed capital in the capital structure rating. Fault factor ø value talks about needs for the cost regulation. Stair-step conception used for counting of the net profit in the accountant period indicates the financial profit, alternatively loss, as the distinguished pre-tax profit element. Picture about firm’s financial results can be completed with the information about the income tax value. Form of financial analyses presented in the article entablature the accents on the necessity to compare several accounting period and on the necessity of complex understanding of statements accounting slide “en bloc”.Financial analyse makes the decision makers possible to screen potential partners before the cooperation starts. On the other side, it makes a possibility to influence the production process, sales and financial management during the accounting

  3. Development and Preliminary Tests of an Open-Path Airborne Diode Laser Absorption Instrument for Carbon Dioxide

    Science.gov (United States)

    Diskin, Glenn S.; DiGangi, Joshua P.; Yang, Melissa; Slate, Thomas A.; Rana, Mario

    2015-01-01

    Carbon dioxide (CO2) is well known for its importance as an atmospheric greenhouse gas, with many sources and sinks around the globe. Understanding the fluxes of carbon into and out of the atmosphere is a complex and daunting challenge. One tool applied by scientists to measure the vertical flux of CO2 near the surface uses the eddy covariance technique, most often from towers but also from aircraft flying specific patterns over the study area. In this technique, variations of constituents of interest are correlated with fluctuations in the local vertical wind velocity. Measurement requirements are stringent, particularly with regard to precision, sensitivity to small changes, and temporal sampling rate. In addition, many aircraft have limited payload capability, so instrument size, weight, and power consumption are also important considerations. We report on the development and preliminary application of an airborne sensor for the measurement of atmospheric CO2. The instrument, modeled on the successful DLH (Diode Laser Hygrometer) series of instruments, has been tested in the laboratory and on the NASA DC-8 aircraft. Performance parameters such as accuracy, precision, sensitivity, specificity, and temporal response are discussed in the context of typical atmospheric variability and suitability for flux measurement applications. On-aircraft, in-flight data have been obtained and are discussed as well. Performance of the instrument has been promising, and continued flight testing is planned during 2016.

  4. Instrumental neutron activation analysis in environmental studies of trace elements

    International Nuclear Information System (INIS)

    Salmon, L.

    1975-06-01

    The application of a routine instrumental nuclear method is described in relation to environmental surveys and studies. A working rather than formal review is made of the techniques applied with particular reference to the data processing methods involved. The elements measured by instrumental activation analysis were: Ag, Al, As, Au, Ba, Br, Ca, Ce, Cl, Cd, Co, Cr, Cs, Cu, Fe, Hg, I, In, La, Mn, Na, Ni, Pb, Rb, Sb, Sc, Se, Th, Ti, U, V, W, Zn. (author)

  5. General and preliminary thermohydraulic, hydrogen and aerosol instrumentation plan for the Phebus Fp-project

    International Nuclear Information System (INIS)

    Hampel, G.; Poss, G.; Frohlich, H.K.

    1989-10-01

    The objective of the project was to draw up an instrumentation plan for the French core melting programme PHEBUS FP. This instrumentation plan essentially was to include proven and reliable instruments for recording various thermohydraulic, aerosol and hydrogen phenomena. The candidate measuring methods, which are known mainly from reactor safety programmes, have been described and examined for their usefulness in PHEBUS. Each method and instrument has been described in detail under various aspects such as measuring principle, measuring range, technical design, evaluation model, calibration procedure, accuracy, previous experience, commercial availability, etc. Special attention has been paid to the behaviour of the measuring transducers when exposed to radiation. First, the performance of the instruments was compared with the requirements of PHEBUS. The results of this comparison served as the basis for a measuring concept in tabular form, giving the locations of the measurements, the measuring tasks, and the number and kind of instruments that are recommended. Redundancy and cost-benefit aspects have been taken into account in qualitative terms

  6. Instrumental neutron activation analysis of kidney stones

    International Nuclear Information System (INIS)

    Sarmani, S.; Kuan, L.L.; Bakar, M.A.A.

    1990-01-01

    Kidney stone samples of the types calcium oxalate, uric acid, and xanthine were analyzed for their elemental contents by neutron activation analysis to study both the elemental correlation and influence of element on stone precipitation processes. Elements, such as Al, Au, Br, Ca, Cl, Co, Cr, Fe,H, I, K, Mg, Na, Sb, Se, Sr, and Zn, were determined quantitatively. Calcium oxalate stones contained higher concentration of all the elements analyzed compared to uric acid or xanthine stones. The concentrations of Cl, Fe, K, Na, Sr, and Zn were relatively higher than Au, Co, Cr, and Sb. A positive correlation exists between Ca and Zn, whereas a negative correlation exists between Sr and Ca. Zinc may play an important role in the formation of calcium oxalate stone

  7. Preliminary ATWS analysis for the IRIS PRA

    International Nuclear Information System (INIS)

    Maddalena Barra; Marco S Ghisu; David J Finnicum; Luca Oriani

    2005-01-01

    Full text of publication follows: The pressurized light water cooled, medium power (1000 MWt) IRIS (International Reactor Innovative and Secure) has been under development for four years by an international consortium of over 21 organizations from ten countries. The plant conceptual design was completed in 2001 and the preliminary design is nearing completion. The pre-application licensing process with NRC started in October, 2002. IRIS has been primarily focused on establishing a design with innovative safety characteristics. The first line of defense in IRIS is to eliminate event initiators that could potentially lead to core damage. In IRIS, this concept is implemented through the 'safety by design' approach, which allows to minimize the number and complexity of the safety systems and required operator actions. The end result is a design with significantly reduced complexity and improved operability, and extensive plant simplifications to enhance construction. To support the optimization of the plant design and confirm the effectiveness of the safety by design approach in mitigating or eliminating events and thus providing a significant reduction in the probability of severe accidents, the PRA is being used as an integral part of the design process. A preliminary but extensive Level 1 PRA model has been developed to support the pre-application licensing of the IRIS design. As a result of the Preliminary IRIS PRA, an optimization of the design from a reliability point of view was completed, and an extremely low (about 1.2 E -8 ) core damage frequency (CDF) was assessed to confirm the impact of the safety by design approach. This first assessment is a result of a PRA model including internal initiating events. During this assessment, several assumptions were necessary to complete the CDF evaluation. In particular Anticipated Transients Without Scram (ATWS) were not included in this initial assessment, because their contribution to core damage frequency was assumed

  8. Instrumentation

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.G.

    1982-01-01

    This chapter reviews the parameters which are important to positron-imaging instruments. It summarizes the options which various groups have explored in designing tomographs and the methods which have been developed to overcome some of the limitations inherent in the technique as well as in present instruments. The chapter is not presented as a defense of positron imaging versus single-photon or other imaging modality, neither does it contain a description of various existing instruments, but rather stresses their common properties and problems. Design parameters which are considered are resolution, sampling requirements, sensitivity, methods of eliminating scattered radiation, random coincidences and attenuation. The implementation of these parameters is considered, with special reference to sampling, choice of detector material, detector ring diameter and shielding and variations in point spread function. Quantitation problems discussed are normalization, and attenuation and random corrections. Present developments mentioned are noise reduction through time-of-flight-assisted tomography and signal to noise improvements through high intrinsic resolution. Extensive bibliography. (U.K.)

  9. Applied research of environmental monitoring using instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Young Sam; Moon, Jong Hwa; Chung, Young Ju

    1997-08-01

    This technical report is written as a guide book for applied research of environmental monitoring using Instrumental Neutron Activation Analysis. The contents are as followings; sampling and sample preparation as a airborne particulate matter, analytical methodologies, data evaluation and interpretation, basic statistical methods of data analysis applied in environmental pollution studies. (author). 23 refs., 7 tabs., 9 figs.

  10. Preliminary safety design analysis of KALIMER

    Energy Technology Data Exchange (ETDEWEB)

    Suk, Soo Dong; Kwon, Y. M.; Kim, K. D. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-03-01

    The national long-term R and D program updated in 1997 requires Korea Atomic Energy Research Institute(KAERI) to complete by the year 2006 the basic design of Korea Advanced Liquid Metal Reactor (KALIMER), along with supporting R and D work, with the capability of resolving the issue of spent fuel storage as well as with significantly enhanced safety. KALIMER is a 150 MWe pool-type sodium cooled prototype reactor that uses metallic fuel. The conceptual design is currently under way to establish a self consistent design meeting a set of the major safety design requirements for accident prevention. Some of current emphasis include those for inherent and passive means of negative reactivity insertion and decay heat removal, high shutdown reliability, prevention of and protection from sodium chemical reaction, and high seismic margin, among others. All of these requirements affect the reactor design significantly and involve supporting R and D programs of substance. This document first introduces a set of safety design requirements and accident evaluation criteria established for the conceptual design of KALIMER and then summarizes some of the preliminary results of engineering and design analyses performed for the safety of KALIMER. 19 refs., 19 figs., 6 tabs. (Author)

  11. Preliminary shielding analysis of VHTR reactors

    International Nuclear Information System (INIS)

    Flaspoehler, Timothy M.; Petrovic, Bojan

    2011-01-01

    Over the last 20 years a number of methods have been established for automated variance reduction in Monte Carlo shielding simulations. Hybrid methods rely on deterministic adjoint and/or forward calculations to generate these parameters. In the present study, we use the FWCADIS method implemented in MAVRIC sequence of the SCALE6 package to perform preliminary shielding analyses of a VHTR reactor. MAVRIC has been successfully used by a number of researchers for a range of shielding applications, including modeling of LWRs, spent fuel storage, radiation field throughout a nuclear power plant, study of irradiation facilities, and others. However, experience in using MAVRIC for shielding studies of VHTRs is more limited. Thus, the objective of this work is to contribute toward validating MAVRIC for such applications, and identify areas for potential improvement. A simplified model of a prismatic VHTR has been devised, based on general features of the 600 MWt reactor considered as one of the NGNP options. Fuel elements have been homogenized, and the core region is represented as an annulus. However, the overall mix of materials and the relatively large dimensions of the spatial domain challenging the shielding simulations have been preserved. Simulations are performed to evaluate fast neutron fluence, dpa, and other parameters of interest at relevant positions. The paper will investigate and discuss both the effectiveness of the automated variance reduction, as well as applicability of physics model from the standpoint of specific VHTR features. (author)

  12. Preliminary Results From a Heavily Instrumented Engine Ice Crystal Icing Test in a Ground Based Altitude Test Facility

    Science.gov (United States)

    Flegel, Ashlie B.; Oliver, Michael J.

    2016-01-01

    Preliminary results from the heavily instrumented ALF502R-5 engine test conducted in the NASA Glenn Research Center Propulsion Systems Laboratory are discussed. The effects of ice crystal icing on a full scale engine is examined and documented. This same model engine, serial number LF01, was used during the inaugural icing test in the Propulsion Systems Laboratory facility. The uncommanded reduction of thrust (rollback) events experienced by this engine in flight were simulated in the facility. Limited instrumentation was used to detect icing on the LF01 engine. Metal temperatures on the exit guide vanes and outer shroud and the load measurement were the only indicators of ice formation. The current study features a similar engine, serial number LF11, which is instrumented to characterize the cloud entering the engine, detect/characterize ice accretion, and visualize the ice accretion in the region of interest. Data were acquired at key LF01 test points and additional points that explored: icing threshold regions, low altitude, high altitude, spinner heat effects, and the influence of varying the facility and engine parameters. For each condition of interest, data were obtained from some selected variations of ice particle median volumetric diameter, total water content, fan speed, and ambient temperature. For several cases the NASA in-house engine icing risk assessment code was used to find conditions that would lead to a rollback event. This study further helped NASA develop necessary icing diagnostic instrumentation, expand the capabilities of the Propulsion Systems Laboratory, and generate a dataset that will be used to develop and validate in-house icing prediction and risk mitigation computational tools. The ice accretion on the outer shroud region was acquired by internal video cameras. The heavily instrumented engine showed good repeatability of icing responses when compared to the key LF01 test points and during day-to-day operation. Other noticeable

  13. Preliminary analysis of B. E. C. I

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, H; Sato, S [Waseda Univ., Tokyo (Japan). Science and Engineering Research Lab.; Saito, T; Noma, M; Matsubayashi, T

    1974-10-01

    An emulsion chamber (B.E.C.I.) with a generating layer, mounted on a baloon, was flown as preliminary experiment in May 1973. The object of this experiment was (1) the observation of high energy cosmic ray, (2) study of ultra-high energy multiple generation phenomenon, and (3) study of ultra-high energy heavy ion nuclear reaction. The emulsion chamber comprises three portions. Upper portion is 130 sheets arranged vertically at 3 mm intervals, each sheet is a 1,500 ..mu..m methacrylic base coated on one side with 200 ..mu..m emulsion. Middle portion comprises horizontally arranged 800 ..mu..m methacrylic bases coated on both sides with 50 ..mu..m emulsion, and a 1 mm methacrylic sheet is inserted every five bases. Lower portion comprises first five layers of the sandwich of 1 mm lead sheet and 800 ..mu..m methacrylic base coated on both sides with 50 ..mu..m emulsion and second ten layers of the sandwich of 2 mm lead sheet, 800 ..mu..m methacrylic base coated on one side with 50 ..mu..m emulsion, and X-ray film of N type. The cascade having energy of Esub(o)>400 GeV as the scanning efficiency of lower E.C.C., the events having incidental energy of Esub(o)>3TeV among the jets occured in lower E.C.C., and the events having incidental energy of Esub(o)>10TeV among the jets occured in generating layer have been observed. Angle distribution of the secondary charged particles of jets produced in the generating layer can be obtained accurately.

  14. A study on feature analysis for musical instrument classification.

    Science.gov (United States)

    Deng, Jeremiah D; Simmermacher, Christian; Cranefield, Stephen

    2008-04-01

    In tackling data mining and pattern recognition tasks, finding a compact but effective set of features has often been found to be a crucial step in the overall problem-solving process. In this paper, we present an empirical study on feature analysis for recognition of classical instrument, using machine learning techniques to select and evaluate features extracted from a number of different feature schemes. It is revealed that there is significant redundancy between and within feature schemes commonly used in practice. Our results suggest that further feature analysis research is necessary in order to optimize feature selection and achieve better results for the instrument recognition problem.

  15. Practical Recommendations for the Preliminary Design Analysis of ...

    African Journals Online (AJOL)

    Interior-to-exterior shear ratios for equal and unequal bay frames, as well as column inflection points were obtained to serve as practical aids for preliminary analysis/design of fixed-feet multistory sway frames. Equal and unequal bay five story frames were analysed to show the validity of the recommended design ...

  16. Yucca Mountain transportation routes: Preliminary characterization and risk analysis

    International Nuclear Information System (INIS)

    Souleyrette, R.R. II; Sathisan, S.K.; di Bartolo, R.

    1991-01-01

    This report presents appendices related to the preliminary assessment and risk analysis for high-level radioactive waste transportation routes to the proposed Yucca Mountain Project repository. Information includes data on population density, traffic volume, ecologically sensitive areas, and accident history

  17. Preliminary analysis of patent trends for magnetic fusion technology

    International Nuclear Information System (INIS)

    Levine, L.O.; Ashton, W.B.; Campbell, R.S.

    1984-02-01

    This study presents a preliminary analysis of development trends in magnetic fusion technology based on data from US patents. The research is limited to identification and description of general patent activity and ownership characteristics for 373 patents. The results suggest that more detailed studies of fusion patents could provide useful R and D planning information

  18. Licensing support system preliminary needs analysis: Volume 1

    International Nuclear Information System (INIS)

    1989-01-01

    This Preliminary Needs Analysis, together with the Preliminary Data Scope Analysis (next in this series of reports), is a first effort under the LSS Design and Implementation Contract toward developing a sound requirements foundation for subsequent design work. Further refinements must be made before requirements can be specified in sufficient detail to provide a basis for suitably specific system specifications. This preliminary analysis of the LSS requirements has been divided into a ''needs'' and a ''data scope'' portion only for project management and scheduling reasons. The Preliminary Data Scope Analysis will address all issues concerning the content and size of the LSS data base; providing the requirements basis for data acquisition, cataloging and storage sizing specifications. This report addresses all other requirements for the LSS. The LSS consists of both computer subsystems and non-computer archives. This study addresses only the computer subsystems, focusing on the Access Subsystems. After providing background on previous LSS-related work, this report summarizes the findings from previous examinations of needs and describes a number of other requirements that have an impact on the LSS. The results of interviews conducted for this report are then described and analyzed. The final section of the report brings all of the key findings together and describes how these needs analyses will continue to be refined and utilized in on-going design activities. 14 refs., 2 figs., 1 tab

  19. Preliminary thermal and stress analysis of the SINQ window

    International Nuclear Information System (INIS)

    Heidenreich, G.

    1991-01-01

    Preliminary results of a finite element analysis for the SINQ proton beam window are presented. Temperatures and stresses are calculated in an axisymmetric model. As a result of these calculations, the H 2 O-cooled window (safety window) could be redesigned in such a way that plastic deformation resulting from excessive stress in some areas is avoided. (author)

  20. Development and Preliminary Testing of a High Precision Long Stroke Slit Change Mechanism for the SPICE Instrument

    Science.gov (United States)

    Paciotti, Gabriel; Humphries, Martin; Rottmeier, Fabrice; Blecha, Luc

    2014-01-01

    In the frame of ESA's Solar Orbiter scientific mission, Almatech has been selected to design, develop and test the Slit Change Mechanism of the SPICE (SPectral Imaging of the Coronal Environment) instrument. In order to guaranty optical cleanliness level while fulfilling stringent positioning accuracies and repeatability requirements for slit positioning in the optical path of the instrument, a linear guiding system based on a double flexible blade arrangement has been selected. The four different slits to be used for the SPICE instrument resulted in a total stroke of 16.5 mm in this linear slit changer arrangement. The combination of long stroke and high precision positioning requirements has been identified as the main design challenge to be validated through breadboard models testing. This paper presents the development of SPICE's Slit Change Mechanism (SCM) and the two-step validation tests successfully performed on breadboard models of its flexible blade support system. The validation test results have demonstrated the full adequacy of the flexible blade guiding system implemented in SPICE's Slit Change Mechanism in a stand-alone configuration. Further breadboard test results, studying the influence of the compliant connection to the SCM linear actuator on an enhanced flexible guiding system design have shown significant enhancements in the positioning accuracy and repeatability of the selected flexible guiding system. Preliminary evaluation of the linear actuator design, including a detailed tolerance analyses, has shown the suitability of this satellite roller screw based mechanism for the actuation of the tested flexible guiding system and compliant connection. The presented development and preliminary testing of the high-precision long-stroke Slit Change Mechanism for the SPICE Instrument are considered fully successful such that future tests considering the full Slit Change Mechanism can be performed, with the gained confidence, directly on a

  1. Preliminary Integrated Safety Analysis Status Report

    International Nuclear Information System (INIS)

    Gwyn, D.

    2001-01-01

    This report provides the status of the potential Monitored Geologic Repository (MGR) Integrated Safety Analysis (EA) by identifying the initial work scope scheduled for completion during the ISA development period, the schedules associated with the tasks identified, safety analysis issues encountered, and a summary of accomplishments during the reporting period. This status covers the period from October 1, 2000 through March 30, 2001

  2. Preliminary Validation of a New Instrument to Measure Life Satisfaction in Adolescents with Neuromuscular Disorders.

    Science.gov (United States)

    Reid, Denise T.; Renwick, Rebecca M.

    1994-01-01

    A new questionnaire instrument, the Life Satisfaction Index for Adolescents (LSIA), has been developed for adolescents with Duchenne muscular dystrophy (DMD). This article reviews the conceptual basis of the LSIA, its development, and its reliability and validity (established with 15 male adolescents with DMD). (DB)

  3. Preliminary analysis of alternative fuel cycles for proliferation evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Steindler, M. J.; Ripfel, H. C.F.; Rainey, R. H.

    1977-01-01

    The ERDA Division of Nuclear Research and Applications proposed 67 nuclear fuel cycles for assessment as to their nonproliferation potential. The object of the assessment was to determine which fuel cycles pose inherently low risk for nuclear weapon proliferation while retaining the major benefits of nuclear energy. This report is a preliminary analysis of these fuel cycles to develop the fuel-recycle data that will complement reactor data, environmental data, and political considerations, which must be included in the overall evaluation. This report presents the preliminary evaluations from ANL, HEDL, ORNL, and SRL and is the basis for a continuing in-depth study. (DLC)

  4. antibacterial properties and preliminary phytochemical analysis

    African Journals Online (AJOL)

    DR. AMINU

    2Department of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Benin, Benin City. *Correspondence ... phytochemical analysis of the dried leaves extracts revealed the presence of alkaloids, ... for the synthesis of useful drugs.

  5. Comparison of instrumental neutron activation analysis and instrumental charged-particle activation analysis for determining of Zn-68 abundance

    International Nuclear Information System (INIS)

    Rafii, H.; Mirzaei, M.; Aslani, G.R.; Kamali-Dehghan, M.; Rajamand, A-A.; Rahiminejad, A.; Mirzajani, N.; Sardari, D.; Shahabi, I.; Majidi, F.

    2004-01-01

    Gallium-67 has found important applications in nuclear medicine since last decades. The bombardment of enriched zinc-68 by proton beams in cyclotron is the most suitable method for the carrier-free production of this radionuclide. Any traces and isotopic impurities of the target cause serious radiological hazards because of their associated induced radioactivities. Trace analysis and Zn-68 content determination of the target material before any bombardment and chemical separation provide a valuable assessment of desired product. The elemental abundance evaluation of enriched isotopes is generally carried out by inductively coupled plasma-mass spectrometry method, ICP-Ms Instrumental neutron activation analysis and instrumental charged particle activation analysis. International neutron activation analysis and instrumental charged- particle activation analysis, looks be an alternative nuclear method for determining the abundance evaluation of enriched Zn-68 enrichment in two different samples has been studied by mean of international neutron activation analysis and instrumental charged- particle activation analysis . One sample was purchased from a French company, cortecnet, and the other was separated by an electromagnetic system in the Ions source department of our center, NRCAM. The neutron or proton irradiation was took place respectively in miniature neutron source reactor of Esfahan by flux of (1 to 5) 10 11 n/cm 2 .sec for 30 min and in Cyclon30 by 19 MeV proton beams of 100μA current for 12 min. The produced radioactivity was measured by HpGe detector for determination of trace impurities and evaluation of Zn-68 content in the samples. The result shows a good agreement with the reported ones by their producers and their low derivation of about ± indicates that the international neutron activation analysis and instrumental charged- particle activation analysis are relatively precise and rapid and each one can be used as a supplemental method for analyzing

  6. Preliminary conceptual design and analysis on KALIMER reactor structures

    International Nuclear Information System (INIS)

    Kim, Jong Bum

    1996-10-01

    The objectives of this study are to perform preliminary conceptual design and structural analyses for KALIMER (Korea Advanced Liquid Metal Reactor) reactor structures to assess the design feasibility and to identify detailed analysis requirements. KALIMER thermal hydraulic system analysis results and neutronic analysis results are not available at present, only-limited preliminary structural analyses have been performed with the assumptions on the thermal loads. The responses of reactor vessel and reactor internal structures were based on the temperature difference of core inlet and outlet and on engineering judgments. Thermal stresses from the assumed temperatures were calculated using ANSYS code through parametric finite element heat transfer and elastic stress analyses. While, based on the results of preliminary conceptual design and structural analyses, the ASME Code limits for the reactor structures were satisfied for the pressure boundary, the needs for inelastic analyses were indicated for evaluation of design adequacy of the support barrel and the thermal liner. To reduce thermal striping effects in the bottom are of UIS due to up-flowing sodium form reactor core, installation of Inconel-718 liner to the bottom area was proposed, and to mitigate thermal shock loads, additional stainless steel liner was also suggested. The design feasibilities of these were validated through simplified preliminary analyses. In conceptual design phase, the implementation of these results will be made for the design of the reactor structures and the reactor internal structures in conjunction with the thermal hydraulic, neutronic, and seismic analyses results. 4 tabs., 24 figs., 4 refs. (Author)

  7. Experience with PET FDG - Preliminary analysis

    International Nuclear Information System (INIS)

    Massardo, Teresa; Jofre, Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Galaz, Rodrigo; Miranda, Karina

    2004-01-01

    Full text: The objective of this preliminary communication was to analyse the indications and data in initial group of patients studied with first dedicated PET scanner in the country at Hospital Militar in Santiago Chile. The main application of positron emission tomography (PET) with 18-Fluoro deoxyglucose (FDG) is related with oncological patients management. We studied 136 patients, 131 (97%) with known or suspected malignant disease and remaining 5 for cardiological or neuropsychiatric disease. Ten patients were controlled diabetics (1 insulin dependent). Their mean age was 51.6±18 years ranging from 6 to 84 years and 65% were females. A total of 177 scans were acquired using a dedicated PET (Siemens HR + with 4mm resolution) system. Mean F18-FDG injected dose was 477±107 MBq (12.9±2.9 mCi). Mean blood glucose levels, performed prior the injection, were 94±17mg/dl (range 62-161). F18-FDG was obtained from the cyclotron IBA Cyclone 18/9 installed in the Chilean Agency of Nuclear Energy, distant about 15 miles away from the clinical PET facility. PET studies were analyzed by at least 4 independent observers visually. Standardized uptake value (SUV) was calculated in some cases. Image fusion of FDG images with recent anatomical (CT, MRI) studies was performed where available. Data acquisition protocol consisted in 7-8 beds/study from head to mid-thighs, with 6-7-min/bed acquisitions, 36% transmission with germanium 68 rods. Data was reconstructed with standard OSEM protocol. The main indications included pulmonary lesions in 31%, gastrointestinal cancers in 21%, melanoma in 13% and lymphoma in 9% patients. The remaining were of breast, thyroid, testes, ovary, musculoskeletal (soft tissue and bone), brain tumour etc. Abnormal focal tracer uptake was observed in 83/131 oncological patients, 54% corroborating with clinical diagnosis of primary tumor or recurrence while 46% showed new metastatic localization. FDG scans were normal 36/131 patients. In 9 patients

  8. Experience with PET FDG - Preliminary analysis

    Energy Technology Data Exchange (ETDEWEB)

    Massardo, Teresa; Jofre, Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Galaz, Rodrigo; Miranda, Karina [Centro PET de Imagenes Moleculares, Hospital Militar de Santiago, Santiago (Chile)

    2004-01-01

    Full text: The objective of this preliminary communication was to analyse the indications and data in initial group of patients studied with first dedicated PET scanner in the country at Hospital Militar in Santiago Chile. The main application of positron emission tomography (PET) with 18-Fluoro deoxyglucose (FDG) is related with oncological patients management. We studied 136 patients, 131 (97%) with known or suspected malignant disease and remaining 5 for cardiological or neuropsychiatric disease. Ten patients were controlled diabetics (1 insulin dependent). Their mean age was 51.6{+-}18 years ranging from 6 to 84 years and 65% were females. A total of 177 scans were acquired using a dedicated PET (Siemens HR + with 4mm resolution) system. Mean F18-FDG injected dose was 477{+-}107 MBq (12.9{+-}2.9 mCi). Mean blood glucose levels, performed prior the injection, were 94{+-}17mg/dl (range 62-161). F18-FDG was obtained from the cyclotron IBA Cyclone 18/9 installed in the Chilean Agency of Nuclear Energy, distant about 15 miles away from the clinical PET facility. PET studies were analyzed by at least 4 independent observers visually. Standardized uptake value (SUV) was calculated in some cases. Image fusion of FDG images with recent anatomical (CT, MRI) studies was performed where available. Data acquisition protocol consisted in 7-8 beds/study from head to mid-thighs, with 6-7-min/bed acquisitions, 36% transmission with germanium 68 rods. Data was reconstructed with standard OSEM protocol. The main indications included pulmonary lesions in 31%, gastrointestinal cancers in 21%, melanoma in 13% and lymphoma in 9% patients. The remaining were of breast, thyroid, testes, ovary, musculoskeletal (soft tissue and bone), brain tumour etc. Abnormal focal tracer uptake was observed in 83/131 oncological patients, 54% corroborating with clinical diagnosis of primary tumor or recurrence while 46% showed new metastatic localization. FDG scans were normal 36/131 patients. In 9

  9. Preliminary engineering analysis for clothes washers

    Energy Technology Data Exchange (ETDEWEB)

    Biermayer, Peter J.

    1996-10-01

    The Engineering Analysis provides information on efficiencies, manufacturer costs, and other characteristics of the appliance class being analyzed. For clothes washers, there are two classes: standard and compact. Since data were not available to analyze the compact class, only clothes washers were analyzed in this report. For this analysis, individual design options were combined and ordered in a manner that resulted in the lowest cumulative cost/savings ratio. The cost/savings ratio is the increase in manufacturer cost for a design option divided by the reduction in operating costs due to fuel and water savings.

  10. Preliminary Results of the VLFE Quadrupole Instrumentation From The PARX Sounding Rocket

    Science.gov (United States)

    Reinleitner, L. A.; Holzworth, R. H.; Meadows, A. L.

    2003-12-01

    The NASA Pulsating Auroral Rocket eXperiment (PARX - March '97 from Poker Flat, AK) was equipped with 4 electric field probes oriented (X and Y) perpendicular to the ambient magnetic field, and one probe (along the Z axis) to obtain the parallel electric field. The rocket also included a three-axis VLF search coil magnetometer. The VLF measurements for both instruments were from 100 Hz - 8 KHz. Additionally, the electric field information was used onboard the rocket to obtain the "quadrupole" electric field, defined to be {(V1+V2) - (V3+V4)}/2d, which shows significant response only to short wavelength waves. This instrumentation clearly shows the long wavelength nature of features tentatively described as auroral hiss, and the shorter wavelength nature of the electrostatic and/or quasi-electrostatic waves.

  11. A quantitative preliminary evaluation of nuclear medicine instruments in the Philippines

    International Nuclear Information System (INIS)

    Valdezco, E.M.; Caseria, E.S.; Lopez, L.B.; Pasion, I.S.; Linilitan, V.E.

    1986-01-01

    This paper is the result of a survey conducted on several nuclear medicine centers in Metro Manila including one in Baguio City to assess the performance of nuclear medicine instruments and the extent of quality procedures being carried out. It was revealed that prompt and competent service seems to be a major problem. Of the eleven sites visited, 4 have cameras only, 4 with cameras with computers, 3 with rectilinear scanners only and 1 with cameras + rectilinear scanners. (ELC) 8 figs

  12. Development and preliminary validation of a post-fistula repair reintegration instrument among Ugandan women

    OpenAIRE

    El Ayadi, Alison; Nalubwama, Hadija; Barageine, Justus; Neilands, Torsten B.; Obore, Susan; Byamugisha, Josaphat; Kakaire, Othman; Mwanje, Haruna; Korn, Abner; Lester, Felicia; Miller, Suellen

    2017-01-01

    Background Obstetric fistula is a debilitating and traumatic birth injury affecting 2?3 million women globally, mostly in sub-Saharan Africa and Asia. Affected women suffer physically, psychologically and socioeconomically. International efforts have increased access to surgical treatment, yet attention to a holistic outcome of post-surgical rehabilitation is nascent. We sought to develop and pilot test a measurement instrument to assess post-surgical family and community reintegration. Metho...

  13. Incorporating Basic Optical Microscopy in the Instrumental Analysis Laboratory

    Science.gov (United States)

    Flowers, Paul A.

    2011-01-01

    A simple and versatile approach to incorporating basic optical microscopy in the undergraduate instrumental analysis laboratory is described. Attaching a miniature CCD spectrometer to the video port of a standard compound microscope yields a visible microspectrophotometer suitable for student investigations of fundamental spectrometry concepts,…

  14. Malaysian English: An Instrumental Analysis of Vowel Contrasts

    Science.gov (United States)

    Pillai, Stefanie; Don, Zuraidah Mohd.; Knowles, Gerald; Tang, Jennifer

    2010-01-01

    This paper makes an instrumental analysis of English vowel monophthongs produced by 47 female Malaysian speakers. The focus is on the distribution of Malaysian English vowels in the vowel space, and the extent to which there is phonetic contrast between traditionally paired vowels. The results indicate that, like neighbouring varieties of English,…

  15. Analysis and application of analog electronic circuits to biomedical instrumentation

    CERN Document Server

    Northrop, Robert B

    2003-01-01

    This book introduces the basic mathematical tools used to describe noise and its propagation through linear systems and provides a basic description of the improvement of signal-to-noise ratio by signal averaging and linear filtering. The text also demonstrates how op amps are the keystone of modern analog signal conditioning systems design, and illustrates their use in isolation and instrumentation amplifiers, active filters, and numerous biomedical instrumentation systems and subsystems. It examines the properties of the ideal op amp and applies this model to the analysis of various circuits

  16. Instrumental biosensors: new perspectives for the analysis of biomolecular interactions.

    Science.gov (United States)

    Nice, E C; Catimel, B

    1999-04-01

    The use of instrumental biosensors in basic research to measure biomolecular interactions in real time is increasing exponentially. Applications include protein-protein, protein-peptide, DNA-protein, DNA-DNA, and lipid-protein interactions. Such techniques have been applied to, for example, antibody-antigen, receptor-ligand, signal transduction, and nuclear receptor studies. This review outlines the principles of two of the most commonly used instruments and highlights specific operating parameters that will assist in optimising experimental design, data generation, and analysis.

  17. Applicability of analytical instrument in trace evidence analysis

    International Nuclear Information System (INIS)

    Sharma, Mukesh; Jha, Shailendra

    2014-01-01

    In the present paper, we explain the importance of the analytical instrument used in the field of forensic science for the analysis of the trace evidences collected from the scene of occurrence. The forensic scientist has to rely upon these instrumental analyses of trace amounts of materials like drugs, toxicological specimens, GSR, fibres, glass, paints, soil etc. Through this paper, reviews on these techniques which are extensively used in forensic sciences are reported. Our report summaries on the basis of analytical problem facing for a forensic expert and techniques employed to tackle them like XRD/XRF, inductively coupled plasma (ICP) techniques, Raman spectroscopy and microscopy (optical, GRIM, electron microscopy, TEM). (author)

  18. Availability analysis of the nuclear instrumentation of a research reactor

    International Nuclear Information System (INIS)

    Vianna Filho, Alfredo Marques

    2016-01-01

    The maintenance of systems and equipment is a central question related to Production Engineering. Although systems are not fully reliable, it is often necessary to minimize the failure occurrence likelihood. The failures occurrences can have disastrous consequences during a plane flight or operation of a nuclear power plant. The elaboration of a maintenance plan has as objective the prevention and recovery from system failures, increasing reliability and reducing the cost of unplanned shutdowns. It is also important to consider the issues related to organizations safety, especially those dealing with dangerous technologies. The objective of this thesis is to propose a method for maintenance analysis of a nuclear research reactor, using a socio-technical approach, and focused on existing conditions in Brazil. The research reactor studied belongs to the federal government and it is located in the city of Rio de Janeiro. The specific objective of this thesis is to develop the availability analysis of one of the principal systems of the research reactor, the nuclear instrumentation system. In this analysis, were taken into account not only the technical aspects of the modules related to nuclear instrumentation system, but also the human and organizational factors that could affect the availability of the nuclear instrumentation system. The results showed the influence of these factors on the availability of the nuclear instrumentation system. (author)

  19. Preliminary analysis of the KAERI RCCS Experiment Using GAMMA+

    Energy Technology Data Exchange (ETDEWEB)

    Khoza, Samukelisiwe; Tak, Nam-il; Lim, Hong-Sik; Lee, Sung-Nam; Cho, Bong-Hyun; Kim, Jong-Hwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    This paper describes the analysis of the KAERI RCCS experiment. GAMMA+ code was used for analysis of the RCCS 1/4-scale natural cooling experimental facility designed and built at KAERI to verify the performance of the natural circulation phenomenon. The results obtained from the GAMMA+ analysis showing the temperature profiles and flow rates at steady state were compared with the results from the preliminary experiments conducted in this facility. GAMMA+ analysis for the KAERI RCCS experimental setup was carried out to understand its natural circulation behavior. The air flow rate at the chimney exit achieved by experiments was from to be almost same as that of GAMMA+.

  20. Gravity field of Venus - A preliminary analysis

    Science.gov (United States)

    Phillips, R. J.; Sjogren, W. L.; Abbott, E. A.; Smith, J. C.; Wimberly, R. N.; Wagner, C. A.

    1979-01-01

    The gravitational field of Venus obtained by tracking the Pioneer Venus Orbiter is examined. For each spacecraft orbit, two hours of Doppler data centered around periapsis were used to estimate spacecraft position and velocity and the velocity residuals obtained were spline fit and differentiated to produce line of sight gravitational accelerations. Consistent variations in line of sight accelerations from orbit to orbit reveal the presence of gravitational anomalies. A simulation of isostatic compensation for an elevated region on the surface of Venus indicates that the mean depth of compensation is no greater than about 100 km. Gravitational spectra obtained from a Fourier analysis of line of sight accelerations from selected Venus orbits are compared to the earth's gravitational spectrum and spherical harmonic gravitational potential power spectra of the earth, the moon and Mars. The Venus power spectrum is found to be remarkably similar to that of the earth, however systematic variations in the harmonics suggest differences in dynamic processes or lithospheric behavior.

  1. Instrumental trace element analysis of California market milk

    International Nuclear Information System (INIS)

    Ragaini, R.C.; Langhorst, A.L.; Ralston, H.R.; Heft, R.

    1975-01-01

    Trace element analysis for 15 elements (Zn, Na, Br, Rb, Sr, Mg, Al, Ca, Cl, I, K, Fe, Co, Se, Cs) was carried out on 32 samples of California market milk and 6 samples of Colorado milk in a pilot study of toxic and nutrient trace elements in the soil-forage-cow-milk food chain. The techniques of instrumental neutron activation analysis and x-ray fluorescence analysis are described. Sample collection, preparation, analysis, and data reduction procedures are discussed. The mean values and variations of trace element concentrations in milk are compared to data from other studies. (U.S.)

  2. Analysis Brazilian preference shares: financial liabilities or equity instruments?

    Directory of Open Access Journals (Sweden)

    Diana Lucia de Almeida

    2016-05-01

    Full Text Available The Brazilian preference shares, in general, except when they present specific features, such as mandatory redemption and cumulative dividends, meet the accounting definition of equity instruments. However, the scientific literature believes that those shares that do not have discretion to avoid the delivery of cash must be classified as financial liabilities. In a context in which remain differences of understanding of their proper accounting treatment, the following question arises: preferred shares of Brazilian companies are being recognized in the financial statements in accordance with the theoretical and normative precepts? Thus, the aim of this study is to verify if the preference shares of Brazilian companies have been recognized in the financial statements for according to the scientific literature and accounting standards. Through content analysis, we analyzed the information of 157 companies listed on BM&FBOVESPA. The results show that 155 companies classify its preference shares as equity instruments and two as financial liabilities. These two companies, as well as 149 of those which qualify as equity instruments, are treating them properly in its accounting. The other six companies should present its preference shares as liabilities, given the absence of discretion to avoid cash delivery, feature present in financial liabilities, unlike equity instruments. It is noticed that, unlike what happens, for instance, in the US market, it is not possible to classify all Brazilian preference shares as a financial liability, since, in Brazil , they are used in different legal format of those widely found in that market. Moreover, almost all of the analyzed shares have essential features for classification as equity instruments. Hence, the importance of analysis of the economic essence of each instrument, thus, enabling the appropriate accounting treatment in the financial statements.

  3. Advanced high conversion PWR: preliminary analysis

    International Nuclear Information System (INIS)

    Golfier, H.; Bellanger, V.; Bergeron, A.; Dolci, F.; Gastaldi, B.; Koberl, O.; Mignot, G.; Thevenot, C.

    2007-01-01

    In this paper, physical aspects of a HCPWR (High Conversion Light Water Reactor), which is an innovative PWR fuelled with mixed oxide and having a higher conversion ratio due to a lower moderation ratio. Moderation ratios lower than unity are considered which has led to low moderation PWR fuel assembly designs. The objectives of this parametric study are to define a feasibility area with regard to the following neutronic aspects: moderation ratio, Pu loading, reactor spectrum, irradiation time, and neutronic coefficients. Important thermohydraulic parameters are the pressure drop, the critical heat flux, the maximum temperature in the fuel rod and the pumping power. The thermohydraulic analysis shows that a range of moderation ratios from 0.8 to 1.2 is technically possible. A compromise between improved fuel utilization and research and development effort has been found for the moderation ration of about 1. The parametric study shows that there are 2 ranges of interest for the moderation ratio: -) moderation ratio between 0.8 and 1.2 with reduced fissile heights (> 3 m), hexagonal arrangement fuel assembly and square arrangement fuel assembly are possible; and -) moderation between 0.6 and 0.7 with a modification of the reactor operating conditions (reduction of the primary flow and of the thermal power), the fuel rods could be arranged inside a hexagonal fuel rod assembly. (A.C.)

  4. A preliminary analysis of bidayuh Jagoi patun

    Directory of Open Access Journals (Sweden)

    Dayang Sariah Abang Suhai

    2013-12-01

    Full Text Available Bidayuh Pantun or Patun remains a under researched topic in Borneo studies and language research due to the difficulties associated with obtaining critical, poetic information in oral culture, language variations and societal mobility. Existing data from anthologies however provide little detail about the instrinsic and extrinsic features ascribed to the poem by the people who produce and use them. This paper attempts to explore patun from the Jagoi community. In this study, the structural aspects, themes and moral values of 47 patun from the Jagoi community were analysed. The initial explanations suggested by the poet were further analysed to determine the various structural features to place it alongside existing mainstream lyric poetry. The analysis of the intrinsic features showed that good rhythmic patun has four to six words per line and eight to 12 syllables per line, and the final syllables of each line has assonance and consonance patterns of a-a-a-a and a-b-a-b. The themes of the patun include love, advice, forgiveness, beliefs, hopelessness and happiness, and the moral values take the form of subtle advice and admonishments. The Bidayuh patun is indeed a projection of knowledge, experiences, beliefs, values, and emotions of the community.

  5. Thermal analysis of an instrumented capsule using an ANSYS program

    International Nuclear Information System (INIS)

    Choi, Myoung Hwan; Choo, Kee Nam; Kang, Young Hwan; Cho, Man Soon; Sohn, Jae Min; Kim, Bong Goo

    2006-01-01

    An instrumented capsule has been used for an irradiation test of various nuclear materials in the research reactor, HANARO. To obtain the design data of the instrumented capsule, a thermal analysis is performed using a finite element analysis program, ANSYS. The 2-dimensional model for a cross section of the capsule including the specimens is generated, and a gamma-heating rate of the materials for the HANARO power of 24 or 30 MW is considered as an input force. The effect of the gap size and the control rod position on the temperature of the specimens or other components is discussed. From the analysis it is found that the gap between the thermal media and the external tube has a significant effect on the temperature of the specimen. In the case of the material capsule, the maximum temperature for the reactor power of 24 MW is 255degC for an irradiation test and 257degC for a FE analysis at the center stage of the capsule in the axial direction. It is expected that the analysis models using an ANSYS program will be useful in designing the instrumented capsules for an irradiation test and estimating the test results. (author)

  6. Remote Access to Instrumental Analysis for Distance Education in Science

    Directory of Open Access Journals (Sweden)

    Dietmar Kennepohl

    2005-11-01

    Full Text Available Remote access to experiments offers distance educators another tool to integrate a strong laboratory component within a science course. Since virtually all modern chemical instrumental analysis in industry now use devices operated by a computer interface, remote control of instrumentation is not only relatively facile, it enhances students’ opportunity to learn the subject matter and be exposed to “real world” contents. Northern Alberta Institute of Technology (NAIT and Athabasca University are developing teaching laboratories based on the control of analytical instruments in real-time via an Internet connection. Students perform real-time analysis using equipment, methods, and skills that are common to modern analytical laboratories (or sophisticated teaching laboratories. Students obtain real results using real substances to arrive at real conclusions, just as they would if they were in a physical laboratory with the equipment; this approach allows students to access to conduct instrumental science experiments, thus providing them with an advantageous route to upgrade their laboratory skills while learning at a distance.

  7. Preliminary Seismic Response and Fragility Analysis for DACS Cabinet

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jinho; Kwag, Shinyoung; Lee, Jongmin; Kim, Youngki [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    A DACS cabinet is installed in the main control room. The objective of this paper is to perform seismic analyses and evaluate the preliminary structural integrity and seismic capacity of the DACS cabinet. For this purpose, a 3-D finite element model of the DACS cabinet was developed and its modal analyses are carried out to analyze the dynamic characteristics. The response spectrum analyses and the related safety evaluation are then performed for the DACS cabinet subject to seismic loads. Finally, the seismic margin and seismic fragility of the DACS cabinet are investigated. A seismic analysis and preliminary structural integrity of the DACS cabinet under self weight and SSE load have been evaluated. For this purpose, 3-D finite element models of the DACS cabinet were developed. A modal analysis, response spectrum analysis, and seismic fragility analysis were then performed. From the structural analysis results, the DACS cabinet is below the structural design limit of under SSE 0.3g, and can structurally withstand until less than SSE 3g based on an evaluation of the maximum effective stresses. The HCLPF capacity for the DGRS of the SSE 0.3g is 0.55g. A modal analysis, response spectrum analysis, and seismic fragility analysis were then performed. From the structural analysis results, the DACS cabinet is below the structural design limit of under SSE 0.3g, and can structurally withstand until less than SSE 3g based on an evaluation of the maximum effective stresses. The HCLPF capacity for the DGRS of the SSE 0.3g is 0.55g. Therefore, it is concluded that the DACS cabinet was safely designed in that no damage to the preliminary structural integrity and sufficient seismic margin is expected.

  8. Preliminary Seismic Response and Fragility Analysis for DACS Cabinet

    International Nuclear Information System (INIS)

    Oh, Jinho; Kwag, Shinyoung; Lee, Jongmin; Kim, Youngki

    2013-01-01

    A DACS cabinet is installed in the main control room. The objective of this paper is to perform seismic analyses and evaluate the preliminary structural integrity and seismic capacity of the DACS cabinet. For this purpose, a 3-D finite element model of the DACS cabinet was developed and its modal analyses are carried out to analyze the dynamic characteristics. The response spectrum analyses and the related safety evaluation are then performed for the DACS cabinet subject to seismic loads. Finally, the seismic margin and seismic fragility of the DACS cabinet are investigated. A seismic analysis and preliminary structural integrity of the DACS cabinet under self weight and SSE load have been evaluated. For this purpose, 3-D finite element models of the DACS cabinet were developed. A modal analysis, response spectrum analysis, and seismic fragility analysis were then performed. From the structural analysis results, the DACS cabinet is below the structural design limit of under SSE 0.3g, and can structurally withstand until less than SSE 3g based on an evaluation of the maximum effective stresses. The HCLPF capacity for the DGRS of the SSE 0.3g is 0.55g. A modal analysis, response spectrum analysis, and seismic fragility analysis were then performed. From the structural analysis results, the DACS cabinet is below the structural design limit of under SSE 0.3g, and can structurally withstand until less than SSE 3g based on an evaluation of the maximum effective stresses. The HCLPF capacity for the DGRS of the SSE 0.3g is 0.55g. Therefore, it is concluded that the DACS cabinet was safely designed in that no damage to the preliminary structural integrity and sufficient seismic margin is expected

  9. Combined Raman/Infrared Reflectance Instrument for In Situ Mineral Analysis, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's Science Instruments, Observatories, and Sensor Systems Roadmap calls for instruments capable of in situ mineralogical analysis in support of planetary...

  10. Engineering Analysis of the Recovered SAFOD Borehole Instrumentation

    International Nuclear Information System (INIS)

    Johnson, Wade

    2014-01-01

    The basic data set was acquired during 18 instrumentation setting tests conducted from 2004 through 2007 as part of SAFOD. Active hydrocarbon-rich water invaded the borehole because the borehole had not sealed at the bottom. For this reason, the water in the casing reached the cable head and caused a malfunction. Attempts were made to use better O rings, Krytox oil, and epoxy seal, but all failed. In most of these deployments, standard wire-line was used and the average failure time was two weeks. Based on design review, many improvements such as stainless tube encapsulate electric cables, all-metal seals, and Swageloks were applied. Setting of improved downhole instrument packages was carried out in the autumn of 2008. Still, these instruments could not endure the high temperature environment of 120 degrees Celsius for a long period of time, and all were offline in less than a month. A SAFOD engineering subcommittee was established in 2010 to investigate the problems caused through an examination of the removed instruments. It became clear that fluid including active hydrocarbons had invaded the stainless tubing from the seal part and caused all instruments to fail. Based on the above-mentioned experience, recommendations for the future are as follows. - Perform strict oversight of subcontractors. - Perform robust risk analysis and prepare a risk mitigation plan. - Multiple checks should be performed on points of failure by different people. - If possible, avoid the use of active electronics in environments like those in SAFOD. - Components must be rated for use in the temperature range of the environment in which they are to be used. - If a failure occurs, remove the instrumentation in a timely manner. - The SAFOD POD design was not inherently flawed but poorly implemented. (author)

  11. Radiochemical and instrumental neutron activation analysis - recent trends

    International Nuclear Information System (INIS)

    Dams, R.

    1990-01-01

    Recent trends of radiochemical and instrumental neutron activation analysis are discussed. Novel developments include the application of cyclic and pulsed activation, better energy resolution with hyperpure germanium detectors, and use of pulse processing systems allowing extremely high count rates of very short-lived isotopes. Further development is anticipated in the field of speciation in biological and environmental studies. Radiochemical methods have led to accurate determinations at the ng/g level. A promising future is expected for neutron activation techniques. (orig.)

  12. A study on cigarette tobacco by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Md Soot Haji Ahmad; Tey Nsan Yen

    1987-01-01

    The concentration of 25 elements in cigarette tobacco of popular brands locally marketed were determined using instrumental neutron activation analysis. These elements are: Al, Ba, Br, Ca, Ce, Cl, Co, Cr, Cs, Eu, Fe, Hf, Hg, K, La, Mg, Mn, Na, Rb, Sb, Sc, Se, Sr, Th, and Zn. Comparison of the element contents to the reported cigarette tobacco of Egypt, Iran and Turkey was also done. (author)

  13. Development of advanced instrumentation for the Phebus FP project-preliminary studies

    International Nuclear Information System (INIS)

    Hampel, G.; Poss, G.

    1989-10-01

    The objective of the project was to examine advanced measuring methods for on-line determination of aerosol, thermohydraulic and hydrogen parameters for their usefulness in the French core melting programme PHEBUS FP. Advanced methods that are known from reactor safety programmes as well as novel measuring techniques as used in related fields such as fuel reprocessing and in non-nuclear process technology have been described and analysed with a view to their potential application in the planned tests. Possibly necessary further developments and modifications have been identified and approaches to solution have been outlined. Special emphasis has been put on the present state of radiation resistant optical fibre wave-guides, which might be integrated in several instruments. As regards the particularly important on-line aerosol measurements in PHEBUS FP, a combined system is recommended as the most promising further development. This novel system configuration comprises the mass monitor of a MESA dust monitoring system and one or several photometers of EIR design

  14. Preliminary Mass Spectrometric Analysis of Uranium on Environmental Swipe Materials

    International Nuclear Information System (INIS)

    Cheong, Chang-Sik; Jeong, Youn-Joong; Ryu, Jong-Sik; Shin, Hyung-Seon; Cha, Hyun-Ju; Ahn, Gil-Hoon; Park, Il-Jin; Min, Gyung-Sik

    2006-01-01

    It is well-known that uranium and plutonium isotopic compositions of safeguards samples are very useful to investigate the history of nuclear activities. To strengthen the capabilities of environmental sampling analysis in the ROK through MOST/DOE collaboration, round robin test for uranium and plutonium was designed in 2003. As the first round robin test, a set of dried uranium-containing solutions (∼35ng and (∼300ng) was distributed to the participating laboratories in November of 2003, with results reported in April of 2004. The KBSI (Korea Basic Science Institute) and ORNL (Oak Ridge National Laboratory) are currently in the process of analyzing uranium on cotton swipes for the second round robin test. As a preliminary test for the second round, KBSI intends to analyze home-made swipe samples into which international uranium standards are added. Here we describe technical steps of sample preparation and mass spectrometry at KBSI, and report some results of the preliminary test

  15. Preliminary study of soil permeability properties using principal component analysis

    Science.gov (United States)

    Yulianti, M.; Sudriani, Y.; Rustini, H. A.

    2018-02-01

    Soil permeability measurement is undoubtedly important in carrying out soil-water research such as rainfall-runoff modelling, irrigation water distribution systems, etc. It is also known that acquiring reliable soil permeability data is rather laborious, time-consuming, and costly. Therefore, it is desirable to develop the prediction model. Several studies of empirical equations for predicting permeability have been undertaken by many researchers. These studies derived the models from areas which soil characteristics are different from Indonesian soil, which suggest a possibility that these permeability models are site-specific. The purpose of this study is to identify which soil parameters correspond strongly to soil permeability and propose a preliminary model for permeability prediction. Principal component analysis (PCA) was applied to 16 parameters analysed from 37 sites consist of 91 samples obtained from Batanghari Watershed. Findings indicated five variables that have strong correlation with soil permeability, and we recommend a preliminary permeability model, which is potential for further development.

  16. Preliminary data on a mnemonic instrument with proverbs for tracking Alzheimer's disease

    Directory of Open Access Journals (Sweden)

    Mauricéa Tabósa Ferreira Santos

    Full Text Available Abstract In the differential diagnosis between Alzheimer's disease (AD and normal aging, tests evaluating memory and executive functions are frequently used. The addition of abstraction tests may enhance the effectiveness of screening tests for AD. Objectives: The aim of this study was to compare initial data of a new instrument - The Screening Test for Alzheimer's Disease with Proverbs (STADP - against other screening tests used in AD diagnosis. Methods: Sixty elderly individuals (46 controls and 14 AD subjects with CDR=1, aged ³60 years, with at least one year of schooling, were evaluated using the STADP at outpatient clinic. The STADP assesses short-term memory, episodic memory, executive functions and language, in addition to proverb recognition. The performance of the participants on the Mini-Mental State Examination (MMSE, semantic Verbal Fluency (VF and Clock Drawing Test (CDT were evaluated and the habit of reading, writing and sociodemographic data were also taken into account. Results: There were significant correlations between STADP and the performance on the MMSE (r=0.64, CDT (r=0.50 and VF (r=0.56. Age influenced all sub-items of the STADP, specifically episodic memory (r= -0.54, whereas schooling mainly influenced executive functions and language (r=0.46. The total score, stages A and C and the "proverb recognition" of STADP (p<0.001, as well as the MMSE (p<0.001, CDT (p=0.016, VF (p<0.001 were significantly different in AD versus control groups. Conclusions: The findings point to the potential use of the STADP in AD, warranting the conducting of further studies.

  17. Preliminary Safety Analysis Report for the Tokamak Physics Experiment

    International Nuclear Information System (INIS)

    Motloch, C.G.; Bonney, R.F.; Levine, J.D.; Masson, L.S.; Commander, J.C.

    1995-04-01

    This Preliminary Safety Analysis Report (PSAR), includes an indication of the magnitude of facility hazards, complexity of facility operations, and the stage of the facility life-cycle. It presents the results of safety analyses, safety assurance programs, identified vulnerabilities, compensatory measures, and, in general, the rationale describing why the Tokamak Physics Experiment (TPX) can be safely operated. It discusses application of the graded approach to the TPX safety analysis, including the basis for using Department of Energy (DOE) Order 5480.23 and DOE-STD-3009-94 in the development of the PSAR

  18. Complex of the equipment for instrumental element analysis

    International Nuclear Information System (INIS)

    Borisov, G.I.; Komkov, M.M.; Kuz'michev, V.A.

    1986-01-01

    Complex of the equipment for instrumental element analysis at the IR-8 reactor is designed, fabricated and taken into operation. The complex is provided with a multichannel system of vacuum pneumatic transport with radiation positions in the reactor horizontal tangential channel for neutron-activation analysis by short-lived isotopes; specialized dry vertical channels in a beryllium reflector of the reactor and remote system of radioactive sample replacement for neutron-activation analysis by long-lived isotopes; a specialized horizontal tangential channel for neutron beam extraction by means of a beryllium converter and remote device for studied sample replacement under radiation and measurement of prompt γ-radiation for neutron-radiation analysis; a measuring center using minicomputers for experimental data accumulation and processing and analysis control

  19. OASIS: An automotive analysis and safety engineering instrument

    International Nuclear Information System (INIS)

    Mader, Roland; Armengaud, Eric; Grießnig, Gerhard; Kreiner, Christian; Steger, Christian; Weiß, Reinhold

    2013-01-01

    In this paper, we describe a novel software tool named OASIS (AutOmotive Analysis and Safety EngIneering InStrument). OASIS supports automotive safety engineering with features allowing the creation of consistent and complete work products and to simplify and automate workflow steps from early analysis through system development to software development. More precisely, it provides support for (a) model creation and reuse, (b) analysis and documentation and (c) configuration and code generation. We present OASIS as a part of a tool chain supporting the application of a safety engineering workflow aligned with the automotive safety standard ISO 26262. In particular, we focus on OASIS' (1) support for property checking and model correction as well as its (2) support for fault tree generation and FMEA (Failure Modes and Effects Analysis) table generation. Finally, based on the case study of hybrid electric vehicle development, we demonstrate that (1) and (2) are able to strongly support FTA (Fault Tree Analysis) and FMEA

  20. Sensitivity analysis and power for instrumental variable studies.

    Science.gov (United States)

    Wang, Xuran; Jiang, Yang; Zhang, Nancy R; Small, Dylan S

    2018-03-31

    In observational studies to estimate treatment effects, unmeasured confounding is often a concern. The instrumental variable (IV) method can control for unmeasured confounding when there is a valid IV. To be a valid IV, a variable needs to be independent of unmeasured confounders and only affect the outcome through affecting the treatment. When applying the IV method, there is often concern that a putative IV is invalid to some degree. We present an approach to sensitivity analysis for the IV method which examines the sensitivity of inferences to violations of IV validity. Specifically, we consider sensitivity when the magnitude of association between the putative IV and the unmeasured confounders and the direct effect of the IV on the outcome are limited in magnitude by a sensitivity parameter. Our approach is based on extending the Anderson-Rubin test and is valid regardless of the strength of the instrument. A power formula for this sensitivity analysis is presented. We illustrate its usage via examples about Mendelian randomization studies and its implications via a comparison of using rare versus common genetic variants as instruments. © 2018, The International Biometric Society.

  1. Analysis of key technologies for virtual instruments metrology

    Science.gov (United States)

    Liu, Guixiong; Xu, Qingui; Gao, Furong; Guan, Qiuju; Fang, Qiang

    2008-12-01

    Virtual instruments (VIs) require metrological verification when applied as measuring instruments. Owing to the software-centered architecture, metrological evaluation of VIs includes two aspects: measurement functions and software characteristics. Complexity of software imposes difficulties on metrological testing of VIs. Key approaches and technologies for metrology evaluation of virtual instruments are investigated and analyzed in this paper. The principal issue is evaluation of measurement uncertainty. The nature and regularity of measurement uncertainty caused by software and algorithms can be evaluated by modeling, simulation, analysis, testing and statistics with support of powerful computing capability of PC. Another concern is evaluation of software features like correctness, reliability, stability, security and real-time of VIs. Technologies from software engineering, software testing and computer security domain can be used for these purposes. For example, a variety of black-box testing, white-box testing and modeling approaches can be used to evaluate the reliability of modules, components, applications and the whole VI software. The security of a VI can be assessed by methods like vulnerability scanning and penetration analysis. In order to facilitate metrology institutions to perform metrological verification of VIs efficiently, an automatic metrological tool for the above validation is essential. Based on technologies of numerical simulation, software testing and system benchmarking, a framework for the automatic tool is proposed in this paper. Investigation on implementation of existing automatic tools that perform calculation of measurement uncertainty, software testing and security assessment demonstrates the feasibility of the automatic framework advanced.

  2. Integrated intelligent instruments using supercritical fluid technology for soil analysis

    International Nuclear Information System (INIS)

    Liebman, S.A.; Phillips, C.; Fitzgerald, W.; Levy, E.J.

    1994-01-01

    Contaminated soils pose a significant challenge for characterization and remediation programs that require rapid, accurate and comprehensive data in the field or laboratory. Environmental analyzers based on supercritical fluid (SF) technology have been designed and developed for meeting these global needs. The analyzers are designated the CHAMP Systems (Chemical Hazards Automated Multimedia Processors). The prototype instrumentation features SF extraction (SFE) and on-line capillary gas chromatographic (GC) analysis with chromatographic and/or spectral identification detectors, such as ultra-violet, Fourier transform infrared and mass spectrometers. Illustrations are given for a highly automated SFE-capillary GC/flame ionization (FID) configuration to provide validated screening analysis for total extractable hydrocarbons within ca. 5--10 min, as well as a full qualitative/quantitative analysis in 25--30 min. Data analysis using optional expert system and neural networks software is demonstrated for test gasoline and diesel oil mixtures in this integrated intelligent instrument approach to trace organic analysis of soils and sediments

  3. Seismic response analysis of an instrumented building structure

    Science.gov (United States)

    Li, H.-J.; Zhu, S.-Y.; Celebi, M.

    2003-01-01

    The Sheraton - Universal hotel, an instrumented building lying in North Hollywood, USA is selected for case study in this paper. The finite element method is used to produce a linear time - invariant structural model, and the SAP2000 program is employed for the time history analysis of the instrumented structure under the base excitation of strong motions recorded in the basement during the Northridge, California earthquake of 17 January 1994. The calculated structural responses are compared with the recorded data in both time domain and frequency domain, and the effects of structural parameters evaluation and indeterminate factors are discussed. Some features of structural response, such as the reason why the peak responses of acceleration in the ninth floor are larger than those in the sixteenth floor, are also explained.

  4. Analysis on detection accuracy of binocular photoelectric instrument optical axis parallelism digital calibration instrument

    Science.gov (United States)

    Ying, Jia-ju; Yin, Jian-ling; Wu, Dong-sheng; Liu, Jie; Chen, Yu-dan

    2017-11-01

    Low-light level night vision device and thermal infrared imaging binocular photoelectric instrument are used widely. The maladjustment of binocular instrument ocular axises parallelism will cause the observer the symptom such as dizziness, nausea, when use for a long time. Binocular photoelectric equipment digital calibration instrument is developed for detecting ocular axises parallelism. And the quantitative value of optical axis deviation can be quantitatively measured. As a testing instrument, the precision must be much higher than the standard of test instrument. Analyzes the factors that influence the accuracy of detection. Factors exist in each testing process link which affect the precision of the detecting instrument. They can be divided into two categories, one category is factors which directly affect the position of reticle image, the other category is factors which affect the calculation the center of reticle image. And the Synthesize error is calculated out. And further distribute the errors reasonably to ensure the accuracy of calibration instruments.

  5. Waste Feed Delivery System Phase 1 Preliminary RAM Analysis

    International Nuclear Information System (INIS)

    DYKES, A.A.

    2000-01-01

    This report presents the updated results of the preliminary reliability, availability, and maintainability (RAM) analysis of selected waste feed delivery (WFD) operations to be performed by the Tank Farm Contractor (TFC) during Phase I activities in support of the Waste Treatment and Immobilization Plant (WTP). For planning purposes, waste feed tanks are being divided into five classes in accordance with the type of waste in each tank and the activities required to retrieve, qualify, and transfer waste feed. This report reflects the baseline design and operating concept, as of the beginning of Fiscal Year 2000, for the delivery of feed from three of these classes, represented by source tanks 241-AN-102, 241-AZ-101 and 241-AN-105. The preliminary RAM analysis quantifies the potential schedule delay associated with operations and maintenance (OBM) field activities needed to accomplish these operations. The RAM analysis is preliminary because the system design, process definition, and activity planning are in a state of evolution. The results are being used to support the continuing development of an O and M Concept tailored to the unique requirements of the WFD Program, which is being documented in various volumes of the Waste Feed Delivery Technical Basis (Carlson. 1999, Rasmussen 1999, and Orme 2000). The waste feed provided to the WTP must: (1) meet limits for chemical and radioactive constituents based on pre-established compositional envelopes (i.e., feed quality); (2) be in acceptable quantities within a prescribed sequence to meet feed quantities; and (3) meet schedule requirements (i.e., feed timing). In the absence of new criteria related to acceptable schedule performance due to the termination of the TWRS Privatization Contract, the original criteria from the Tank Waste Remediation System (77443s) Privatization Contract (DOE 1998) will continue to be used for this analysis

  6. Instrument for Analysis of Organic Compounds on Other Planets

    Science.gov (United States)

    Daulton, Riley M.; Hintze, Paul E.

    2016-01-01

    The goal of this project is to develop the Instrument for Solvent Extraction and Analysis of Extraterrestrial Bodies using In Situ Resources (ISEE). Specifically, ISEE will extract and characterize organic compounds from regolith which is found on the surface of other planets or asteroids. The techniques this instrument will use are supercritical fluid extraction (SFE) and supercritical fluid chromatography (SFC). ISEE aligns with NASA's goal to expand the frontiers of knowledge, capability, and opportunities in space in addition to supporting NASA's aim to search for life elsewhere by characterizing organic compounds. The outcome of this project will be conceptual designs of 2 components of the ISEE instrument as well as the completion of proof-of-concept extraction experiments to demonstrate the capabilities of SFE. The first conceptual design is a pressure vessel to be used for the extraction of the organic compounds from the regolith. This includes a comparison of different materials, geometry's, and a proposition of how to insert the regolith into the vessel. The second conceptual design identifies commercially available fluid pumps based on the requirements needed to generate supercritical CO2. The proof-of-concept extraction results show the percent mass lost during standard solvent extractions of regolith with organic compounds. This data will be compared to SFE results to demonstrate the capabilities of ISEE's approach.

  7. Preliminary analysis of a target factory for laser fusion

    International Nuclear Information System (INIS)

    Sherohman, J.W.; Hendricks, C.D.

    1980-01-01

    An analysis of a target factory leading to the determination of production expressions has provided for the basis of a parametric study. Parameters involving the input and output rate of a process system, processing yield factors, and multiple processing steps and production lines have been used to develop an understanding of their dependence on the rate of target injection for laser fusion. Preliminary results have indicated that a parametric study of this type will be important in the selection of processing methods to be used in the final production scheme of a target factory

  8. Determinants of Trade Credit: A Preliminary Analysis on Construction Sector

    Directory of Open Access Journals (Sweden)

    Nicoleta Barbuta-Misu

    2016-07-01

    Full Text Available This paper introduces a preliminary analysis of the correlations between trade credit and some selected measures of financial performance for a sample of 958 firms acting in the construction sector. The examined period covers 2004-2013. The sample derived from Amadeus database contains firms that have sold and bought on credit. Results showed that larger firms offered and used more credit than counterparties. Firms offered and used in same time credit, but not in same level. Firms with higher return on assets and profit margin used and offered less credit from suppliers, respectively to clients. Moreover, more liquid firms used less trade payables.

  9. Instrumental analysis for mercury in thumbnails of human subjects

    Energy Technology Data Exchange (ETDEWEB)

    Kanabrocki, E L; Kanabrocki, J A; Greco, J [Veterans Administration Hospital, Hines, Ill. (USA)

    1977-07-01

    Mercury levels in thumbnails were determined by instrumental analysis using thermal neutron activation technique. Samples were obtained from 14 subjects employed in the hospital dental service (a), 19 in the clinical laboratories (b), and from 16 hospitalized patients who were not employed in laboratory occupations (c). The average mercury levels in ppM for the respective groups were: (a) dentists, 2.7; technicians, 3.9; assistants, 6.6; (b) male technicians, 0.4; female technicians, 1.9; (c) patients, 0.3.

  10. Certification of biological reference materials by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Lanjewar, Mamata R.; Lanjewar, R.B.

    2014-01-01

    A multielemental instrumental neutron activation analysis (INAA) method by short and long irradiation has been employed for the determination of 21 minor and trace elements in two standard Reference Materials P-RBF and P-WBF from Institute of Radioecology and Applied Nuclear Techniques ,Czechoslovakia. Also some biological standards such as Bowen's kale, cabbage leaves (Poland) including wheat and rice flour samples of local origin were analysed. It is suggested that INAA is an ideal method for the certification of Reference Materials of Biological Matrices. (author)

  11. Instrumental neutron activation analysis of wheat bunt spores

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y G; Schmitt, R A [Oregon State Univ., Corvallis (USA). Dept. of Chemistry; Oregon State Univ., Corvallis (USA). Radiation Center); Trione, E J [Oregon State Univ., Corvallis (USA). Dept. of Botany; Laul, J C [Battelle Pacific Northwest Labs., Richland, WA (USA)

    1982-01-01

    The concentrations of seventeen elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Cr, Mn, Fe, Co, Zn, Br, Rb, La, Sm) in two species of fungus which cause wheat bunt disease, Tilletia caries (DC.) Tul. and Tilletia controversa Kuehn, were determined by instrumental neutron activation analysis. A standard sequential INAA procedure was used. Differences in the K and Cl concentrations between these two species of spores are large and therefore can be used as a criterion of distinguishing between the two species of fungus.

  12. CONTENT ANALYSIS, DISCOURSE ANALYSIS, AND CONVERSATION ANALYSIS: PRELIMINARY STUDY ON CONCEPTUAL AND THEORETICAL METHODOLOGICAL DIFFERENCES

    Directory of Open Access Journals (Sweden)

    Anderson Tiago Peixoto Gonçalves

    2016-08-01

    Full Text Available This theoretical essay aims to reflect on three models of text interpretation used in qualitative research, which is often confused in its concepts and methodologies (Content Analysis, Discourse Analysis, and Conversation Analysis. After the presentation of the concepts, the essay proposes a preliminary discussion on conceptual and theoretical methodological differences perceived between them. A review of the literature was performed to support the conceptual and theoretical methodological discussion. It could be verified that the models have differences related to the type of strategy used in the treatment of texts, the type of approach, and the appropriate theoretical position.

  13. Job/task analysis for I ampersand C [Instrumentation and Controls] instrument technicians at the High Flux Isotope Reactor

    International Nuclear Information System (INIS)

    Duke, L.L.

    1989-09-01

    To comply with Department of Energy Order 5480.XX (Draft), a job/task analysis was initiated by the Maintenance Management Department at Oak Ridge National Laboratory (ORNL). The analysis was applicable to instrument technicians working at the ORNL High Flux Isotope Reactor (HFIR). This document presents the procedures and results of that analysis. 2 refs., 2 figs

  14. Structural analysis of HyFlex EDM instruments.

    Science.gov (United States)

    Iacono, F; Pirani, C; Generali, L; Bolelli, G; Sassatelli, P; Lusvarghi, L; Gandolfi, M G; Giorgini, L; Prati, C

    2017-03-01

    To compare the phase transformation behaviour, the microstructure, the nano-hardness and the surface chemistry of electro-discharge machined HyFlex EDM instruments with conventionally manufactured HyFlex CM. New and laboratory used HyFlex EDM were examined by X-ray diffraction (XRD) and differential scanning calorimetry (DSC). Nano-hardness and modulus of elasticity were also investigated using a maximum load of 20 mN with a minimum of 40 significant indentations for each sample. Raman spectroscopy and field emission-scanning electron microscope (FE-SEM) were used to assess the surface chemistry of HyFlex EDM. HyFlex CM were subjected to the same investigations and used as a comparison. Nano-indentation data were statistically analysed using the Student's t-test. XRD analysis on HyFlex EDM revealed the presence of martensite and rhombohedral R-phase, while a mixture of martensite and austenite structure was identified in HyFlex CM. DSC analysis also disclosed higher austenite finish (Af) temperatures for electro-discharge machining (EDM) instruments. Significant differences in nano-hardness and modulus of elasticity were found between EDM and CM files (P EDM and CM files were covered by an oxide layer. Micro-Raman spectroscopy assessed the presence of rutile-TiO 2 . HyFlex EDM revealed peculiar structural properties, such as increased phase transformation temperatures and hardness. Present results corroborated previous findings and shed light on the enhanced mechanical behaviour of these instruments. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  15. Air pollution assessment in two Moroccan cities using instrumental neutron activation analysis on bio-accumulators

    International Nuclear Information System (INIS)

    Embarch, K.; Moutea, Z.; Bounakhla, M.; Cherkaoui, R.; Chouak, A.; Lferde, M.; Gaudry, A.

    2008-01-01

    Full text: Biomonitoring is an appropriate tool for the air pollution assessment studies. In this work, lichens and barks have been used as bio-accumulators in several sites in two Moroccan cities (Rabat and Mohammadia). The specific ability of absorbing and accumulating heavy metals and toxic element from the air, their longevity and resistance to the environmental stresses, make those bioindicators suitable for this kind of studies. The Instrumental Neutron Activation Analysis (INAA) is universally accepted as one of the most reliable analytical tools for trace and ultra-trace elements determination. Its use in trace elements atmospheric pollution related studies has been and is still extensive as can be demonstrated by several specific works and detailed reviews. In this work, a preliminary investigation employing lichens, barks and instrumental neutron activation analysis (INAA) was carried out to evaluate the trace elements distribution in six different areas of Rabat and Mohammadia cities characterised by the presence of many industries and heavy traffic. Samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted using high-resolution Germanium-Lithium detectors. More than 30 elements were determined using two modes : short irradiation (1 minute) and long irradiation (17 hours). Accuracy and quality control were assessed using the reference standard material IAEA-336. This was less than 1% for major and about 5 to 10% for traces. [fr

  16. Enhanced Accident Tolerant Fuels for LWRS - A Preliminary Systems Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gilles Youinou; R. Sonat Sen

    2013-09-01

    The severe accident at Fukushima Daiichi nuclear plants illustrates the need for continuous improvements through developing and implementing technologies that contribute to safe, reliable and cost-effective operation of the nuclear fleet. Development of enhanced accident tolerant fuel contributes to this effort. These fuels, in comparison with the standard zircaloy – UO2 system currently used by the LWR industry, should be designed such that they tolerate loss of active cooling in the core for a longer time period (depending on the LWR system and accident scenario) while maintaining or improving the fuel performance during normal operations, operational transients, and design-basis events. This report presents a preliminary systems analysis related to most of these concepts. The potential impacts of these innovative LWR fuels on the front-end of the fuel cycle, on the reactor operation and on the back-end of the fuel cycle are succinctly described without having the pretension of being exhaustive. Since the design of these various concepts is still a work in progress, this analysis can only be preliminary and could be updated as the designs converge on their respective final version.

  17. Mini-DIAL system measurements coupled with multivariate data analysis to identify TIC and TIM simulants: preliminary absorption database analysis

    International Nuclear Information System (INIS)

    Gaudio, P; Malizia, A; Gelfusa, M; Poggi, L.A.; Martinelli, E.; Di Natale, C.; Bellecci, C.

    2017-01-01

    Nowadays Toxic Industrial Components (TICs) and Toxic Industrial Materials (TIMs) are one of the most dangerous and diffuse vehicle of contamination in urban and industrial areas. The academic world together with the industrial and military one are working on innovative solutions to monitor the diffusion in atmosphere of such pollutants. In this phase the most common commercial sensors are based on “point detection” technology but it is clear that such instruments cannot satisfy the needs of the smart cities. The new challenge is developing stand-off systems to continuously monitor the atmosphere. Quantum Electronics and Plasma Physics (QEP) research group has a long experience in laser system development and has built two demonstrators based on DIAL (Differential Absorption of Light) technology could be able to identify chemical agents in atmosphere. In this work the authors will present one of those DIAL system, the miniaturized one, together with the preliminary results of an experimental campaign conducted on TICs and TIMs simulants in cell with aim of use the absorption database for the further atmospheric an analysis using the same DIAL system. The experimental results are analysed with standard multivariate data analysis technique as Principal Component Analysis (PCA) to develop a classification model aimed at identifying organic chemical compound in atmosphere. The preliminary results of absorption coefficients of some chemical compound are shown together pre PCA analysis. (paper)

  18. Advanced concepts for gamma-ray isotopic analysis and instrumentation

    International Nuclear Information System (INIS)

    Buckley, W.M.; Carlson, J.B.

    1994-07-01

    The Safeguards Technology Program at the Lawrence Livermore National Laboratory is developing actinide isotopic analysis technologies in response to needs that address issues of flexibility of analysis, robustness of analysis, ease-of-use, automation and portability. Recent developments such as the Intelligent Actinide Analysis System (IAAS), begin to address these issues. We are continuing to develop enhancements on this and other instruments that improve ease-of-use, automation and portability. Requests to analyze samples with unusual isotopics, contamination, or containers have made us aware of the need for more flexible and robust analysis. We have modified the MGA program to extend its plutonium isotopic analysis capability to samples with greater 241 Am content or U isotopics. We are looking at methods for dealing with tantalum or lead contamination and contamination with high-energy gamma emitters, such as 233 U. We are looking at ways to allow the program to use additional information about the sample to further extend the domain of analyzable samples. These unusual analyses will come from the domain of samples that need to be measured because of complex reconfiguration or environmental cleanup

  19. Seismic response of transamerical building. I. Data and preliminary analysis

    Science.gov (United States)

    Celebi, M.; Safak, E.

    1991-01-01

    The objective of this paper is to present preliminary analyses of a set of acceleration response records obtained during the October 17, 1989 Loma Prieta earthquake (Ms = 7.1) from the 60-story vertically tapered, pyramid-shaped Trans-america Building-a landmark of San Francisco. The building was instrumented in 1985 with 22 channels of synchronized sensors consisting of 13 uniaxial accelerometers deployed throughout the structure and connected to a central recording system and three triaxial strong-motion accelerographs at three different levels of the structure. No free-field accelerographs are at the site. The acceleration records permit the study of the behavior of this unique structure. The predominant translational response of the building and the associated frequency at approximately 0.28 Hz are identified from the records and their Fourier amplitude spectra. The records do not indicate any significant torsional motion. However, there is rocking type soil-structure interaction, and an associated frequency of approximately 2.0 Hz is identified from the Fourier amplitude spectra of the differential motions between the ground level and that at the basement. In addition, the response spectra for the basement motions indicate significant resonance in both directions at a period of approximately 0.5 seconds.

  20. Preliminary hazards analysis of thermal scrap stabilization system. Revision 1

    International Nuclear Information System (INIS)

    Lewis, W.S.

    1994-01-01

    This preliminary analysis examined the HA-21I glovebox and its supporting systems for potential process hazards. Upon further analysis, the thermal stabilization system has been installed in gloveboxes HC-21A and HC-21C. The use of HC-21C and HC-21A simplified the initial safety analysis. In addition, these gloveboxes were cleaner and required less modification for operation than glovebox HA-21I. While this document refers to glovebox HA-21I for the hazards analysis performed, glovebox HC-21C is sufficiently similar that the following analysis is also valid for HC-21C. This hazards analysis document is being re-released as revision 1 to include the updated flowsheet document (Appendix C) and the updated design basis (Appendix D). The revised Process Flow Schematic has also been included (Appendix E). This Current revision incorporates the recommendations provided from the original hazards analysis as well. The System Design Description (SDD) has also been appended (Appendix H) to document the bases for Safety Classification of thermal stabilization equipment

  1. Analysis preliminary phytochemical raw extract of leaves Nephrolepis pectinata

    Directory of Open Access Journals (Sweden)

    Natally Marreiros Gomes

    2017-06-01

    Full Text Available The Nephrolepis pectinata popularly known as paulista fern, ladder-heaven, cat tail, belongs to the family Davalliaceae. For the beauty of the arrangements of their leaves ferns are quite commercialized in Brazil, however, have not been described in the literature studies on their pharmacological potential. Thus, the objective of this research was to analyze the phytochemical properties of the crude extract of the leaves of Nephrolepis pectinata. To perform the phytochemical analysis were initially made the collection of the vegetable, preparation of voucher specimen, washing, drying and grinding. Then, extraction by percolation method and end the phytochemical analysis. Preliminary results phytochemicals the crude extract of the leaves of Nephrolepis pectinata tested positive for reducing sugars, phenols/tannins (catechins tannins and catechins.

  2. Preliminary analysis of accident in SST-1 current feeder system

    International Nuclear Information System (INIS)

    Roy, Swati; Kanabar, Deven; Garg, Atul; Singh, Amit; Tanna, Vipul; Prasad, Upendra; Srinivasan, R.

    2017-01-01

    Steady-state Tokamak-1 (SST-1) has 16 superconducting Toroidal field (TF) and 9 superconducting poloidal field (PF) coils rated for 10kA DC. All the TF are connected in series and are operated in DC condition whereas PF coils are individually operated in pulse mode during SST-1 campaigns. SST-1 current feeder system (CFS) houses 9 pairs of PF current leads and 1 pair of TF current leads. During past SST-1 campaign, there were arcing incidents within SST-1 CFS chamber which caused significant damage to PF superconducting current leads as well as its Helium cooling lines of the current leads. This paper brings out the preliminary analysis of the mentioned arcing incident, possible reasons and its investigation thereby laying out the sequence of events. From this analysis and observations, various measures to avoid such arcing incidents have also been proposed. (author)

  3. Limits of detection in instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Guinn, V.P.

    1990-01-01

    Lower limits of detection (LLODs), frequently referred to simply as limits of detection and abbreviated as LODs, often appear in the literature of analytical chemistry - for numerous different methods of elemental and/or molecular analysis. In this chapter, one particular method of quantitative elemental analysis, that of instrumental neutron activation analysis (INAA), is the subject discussed, with reference to LODs. Particularly in the literature of neutron activation analysis (NAA), many tables of 'interference-free' NAA LODs are available. Not all of these are of much use, because (1) for many the definition used for LOD is not clear, or reasonable, (2) for many, the analysis conditions used are not clearly specified, and (3) for many, the analysis conditions used are specified, but not very practicable for most laboratories. For NAA work, such tables of interference-free LODs are, in any case, only applicable to samples in which, at the time of counting, only one radionuclide is present to any significant extent in the activated sample. It is important to note that tables of INAA LODs, per se, do not exist - since the LOD for a given element, under stated analysis conditions, can vary by orders of magnitude, depending on the elemental composition of the matrix in which it is present. For any given element, its INAA LOD will always be as large as, and usually much larger than, its tabulated 'interference-free' NAA LOD - how much larger depending upon the elemental composition of the matrix in which it is present. As discussed in this chapter, however, an INAA computer program exists that can calculate realistic INAA LODs for any elements of interest, in any kind of specified sample matrix, under any given set of analysis conditions

  4. Preliminary RAMI analysis of WCLL blanket and breeder systems

    International Nuclear Information System (INIS)

    Arroyo, Jose Manuel; Brown, Richard; Harman, Jon; Rosa, Elena; Ibarra, Angel

    2015-01-01

    Highlights: • Preliminary RAMI model for WCLL has been developed. • Critical parts and parameters influencing WCLL availability have been focused. • Necessary developments of tools/models to represent system performance have been identified. - Abstract: DEMO will be a prototype fusion reactor designed to prove the capability to produce electrical power in a commercially acceptable way. One of the key factors in that endeavor is the achievement of certain level of plant availability. Therefore, RAMI (Reliability, Availability, Maintainability and Inspectability) will be a key element in the engineering development of DEMO. Some studies have been started so as to develop the tools and models to assess different design alternatives from RAMI point of view. The main objective of these studies is to be able to evaluate the influence of different parameters on DEMO availability and to focus the critical parts that should be further researched and improved in order to develop a high-availability oriented DEMO design. A preliminary RAMI analysis of the Water Cooled Lithium-Lead (WCLL) blanket and breeder concept for DEMO has been developed. The amounts of single elements that may fail (e.g. more than 180,000 C-shaped tubes) and the mean down time associated to failures inside the vacuum vessel (around 3 months) have been highlighted as the critical parameters influencing the system availability. On the other hand, the necessary developments of tools/models to better represent the system performance have been identified and proposed for future work.

  5. Preliminary RAMI analysis of WCLL blanket and breeder systems

    Energy Technology Data Exchange (ETDEWEB)

    Arroyo, Jose Manuel, E-mail: josemanuel.arroyo@ciemat.es [Laboratorio Nacional de Fusión por Confinamiento Magnético – CIEMAT, Madrid (Spain); Brown, Richard [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon (United Kingdom); Harman, Jon [EFDA Close Support Unit, Garching (Germany); Rosa, Elena; Ibarra, Angel [Laboratorio Nacional de Fusión por Confinamiento Magnético – CIEMAT, Madrid (Spain)

    2015-10-15

    Highlights: • Preliminary RAMI model for WCLL has been developed. • Critical parts and parameters influencing WCLL availability have been focused. • Necessary developments of tools/models to represent system performance have been identified. - Abstract: DEMO will be a prototype fusion reactor designed to prove the capability to produce electrical power in a commercially acceptable way. One of the key factors in that endeavor is the achievement of certain level of plant availability. Therefore, RAMI (Reliability, Availability, Maintainability and Inspectability) will be a key element in the engineering development of DEMO. Some studies have been started so as to develop the tools and models to assess different design alternatives from RAMI point of view. The main objective of these studies is to be able to evaluate the influence of different parameters on DEMO availability and to focus the critical parts that should be further researched and improved in order to develop a high-availability oriented DEMO design. A preliminary RAMI analysis of the Water Cooled Lithium-Lead (WCLL) blanket and breeder concept for DEMO has been developed. The amounts of single elements that may fail (e.g. more than 180,000 C-shaped tubes) and the mean down time associated to failures inside the vacuum vessel (around 3 months) have been highlighted as the critical parameters influencing the system availability. On the other hand, the necessary developments of tools/models to better represent the system performance have been identified and proposed for future work.

  6. Analysis instruments for the performance of Advanced Practice Nursing.

    Science.gov (United States)

    Sevilla-Guerra, Sonia; Zabalegui, Adelaida

    2017-11-29

    Advanced Practice Nursing has been a reality in the international context for several decades and recently new nursing profiles have been developed in Spain as well that follow this model. The consolidation of these advanced practice roles has also led to of the creation of tools that attempt to define and evaluate their functions. This study aims to identify and explore the existing instruments that enable the domains of Advanced Practice Nursing to be defined. A review of existing international questionnaires and instruments was undertaken, including an analysis of the design process, the domains/dimensions defined, the main results and an exploration of clinimetric properties. Seven studies were analysed but not all proved to be valid, stable or reliable tools. One included tool was able to differentiate between the functions of the general nurse and the advanced practice nurse by the level of activities undertaken within the five domains described. These tools are necessary to evaluate the scope of advanced practice in new nursing roles that correspond to other international models of competencies and practice domains. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  7. The Sample Analysis at Mars Investigation and Instrument Suite

    Science.gov (United States)

    Mahaffy, Paul; Webster, Christopher R.; Conrad, Pamela G.; Arvey, Robert; Bleacher, Lora; Brinckerhoff, William B.; Eigenbrode, Jennifer L.; Chalmers, Robert A.; Dworkin, Jason P.; Errigo, Therese; hide

    2012-01-01

    The Sample Analysis at Mars (SAM) investigation of the Mars Science Laboratory (MSL) addresses the chemical and isotopic composition of the atmosphere and volatiles extracted from solid samples. The SAM investigation is designed to contribute substantially to the mission goal of quantitatively assessing the habitability of Mars as an essential step in the search for past or present life on Mars. SAM is a 40 kg instrument suite located in the interior of MSL's Curiosity rover. The SAM instruments are a quadrupole mass spectrometer, a tunable laser spectrometer, and a 6-column gas chromatograph all coupled through solid and gas processing systems to provide complementary information on the same samples. The SAM suite is able to measure a suite of light isotopes and to analyze volatiles directly from the atmosphere or thermally released from solid samples. In addition to measurements of simple inorganic compounds and noble gases SAM will conduct a sensitive search for organic compounds with either thermal or chemical extraction from sieved samples delivered by the sample processing system on the Curiosity rover's robotic arm,

  8. Absolute instrumental neutron activation analysis at Lawrence Livermore Laboratory

    International Nuclear Information System (INIS)

    Heft, R.E.

    1977-01-01

    The Environmental Science Division at Lawrence Livermore Laboratory has in use a system of absolute Instrumental Neutron Activation Analysis (INAA). Basically, absolute INAA is dependent upon the absolute measurement of the disintegration rates of the nuclides produced by neutron capture. From such disintegration rate data, the amount of the target element present in the irradiated sample is calculated by dividing the observed disintegration rate for each nuclide by the expected value for the disintegration rate per microgram of the target element that produced the nuclide. In absolute INAA, the expected value for disintegration rate per microgram is calculated from nuclear parameters and from measured values of both thermal and epithermal neutron fluxes which were present during irradiation. Absolute INAA does not depend on the concurrent irradiation of elemental standards but does depend on the values for thermal and epithermal neutron capture cross-sections for the target nuclides. A description of the analytical method is presented

  9. Preliminary analysis of biomass potentially useful for producing biodiesel

    International Nuclear Information System (INIS)

    Cabrera Cifuentes, Gerardo; Burbano Jaramillo, Juan Carlos; Garcia Melo, Jose Isidro

    2011-01-01

    Given that biodiesel is emerging as a viable solution for some energy and environmental problems, research on raw materials appropriate for its production is a matter of growing interest. In this study we present the results of research devoted to preliminary analysis on several vegetable (biomass) species potentially useful for producing biodiesel. The bioprospection zone is a region on the Colombian Pacific coast. The candidate species collected underwent different standardized ASTM tests in order for us to define properties that facilitate their evaluation. Some of the species underwent a transesterification process. Comparisons between the thermo-physical properties of the biofuels obtained and the properties of commercial diesel were carried out. Also, performance tests for these biofuels were conducted in compression ignition engines, particularly evaluating efficiency, fuel consumption, and potency at different RPMs.

  10. Preliminary radar systems analysis for Venus orbiter missions

    Science.gov (United States)

    Brandenburg, R. K.; Spadoni, D. J.

    1971-01-01

    A short, preliminary analysis is presented of the problems involved in mapping the surface of Venus with radar from an orbiting spacecraft. Two types of radar, the noncoherent sidelooking and the focused synthetic aperture systems, are sized to fulfill two assumed levels of Venus exploration. The two exploration levels, regional and local, assumed for this study are based on previous Astro Sciences work (Klopp 1969). The regional level is defined as 1 to 3 kilometer spatial and 0.5 to 1 km vertical resolution of 100 percent 0 of the planet's surface. The local level is defined as 100 to 200 meter spatial and 50-10 m vertical resolution of about 100 percent of the surfAce (based on the regional survey). A 10cm operating frequency was chosen for both radar systems in order to minimize the antenna size and maximize the apparent radar cross section of the surface.

  11. Development of a Symptom-Based Patient-Reported Outcome Instrument for Functional Dyspepsia: A Preliminary Conceptual Model and an Evaluation of the Adequacy of Existing Instruments.

    Science.gov (United States)

    Taylor, Fiona; Reasner, David S; Carson, Robyn T; Deal, Linda S; Foley, Catherine; Iovin, Ramon; Lundy, J Jason; Pompilus, Farrah; Shields, Alan L; Silberg, Debra G

    2016-10-01

    The aim was to document, from the perspective of the empirical literature, the primary symptoms of functional dyspepsia (FD), evaluate the extent to which existing questionnaires target those symptoms, and, finally, identify any missing evidence that would impact the questionnaires' use in regulated clinical trials to assess treatment efficacy claims intended for product labeling. A literature review was conducted to identify the primary symptoms of FD and existing symptom-based FD patient-reported outcome (PRO) instruments. Following a database search, abstracts were screened and articles were retrieved for review. The primary symptoms of FD were organized into a conceptual model and the PRO instruments were evaluated for conceptual coverage as well as compared against evidentiary requirements presented in the FDA's PRO Guidance for Industry. Fifty-six articles and 16 instruments assessing FD symptoms were reviewed. Concepts listed in the Rome III criteria for FD (n = 7), those assessed by existing FD instruments (n = 34), and symptoms reported by patients in published qualitative research (n = 6) were summarized in the FD conceptual model. Except for vomiting, all of the identified symptoms from the published qualitative research reports were also specified in the Rome III criteria. Only three of the 16 instruments, the Dyspepsia Symptom Severity Index (DSSI), Nepean Dyspepsia Index (NDI), and Short-Form Nepean Dyspepsia Index (SF-NDI), measure all seven FD symptoms defined by the Rome III criteria. Among these three, each utilizes a 2-week recall period and 5-point Likert-type scale, and had evidence of patient involvement in development. Despite their coverage, when these instruments were evaluated in light of regulatory expectations, several issues jeopardized their potential qualification for substantiation of a labeling claim. No existing PRO instruments that measured all seven symptoms adhered to the regulatory principles necessary to support product

  12. Preliminary Experimental Analysis of Soil Stabilizers for Contamination Control

    International Nuclear Information System (INIS)

    Lagos, L.; Varona, J.; Zidan, A.; Gudavalli, R.; Wu, Kuang-His

    2006-01-01

    A major focus of Department of Energy's (DOE's) environmental management mission at the Hanford site involves characterizing and remediating contaminated soil and groundwater; stabilizing contaminated soil; remediating disposal sites; decontaminating and decommissioning structures, and demolishing former plutonium production process buildings, nuclear reactors, and separation plants; maintaining inactive waste sites; transitioning facilities into the surveillance and maintenance program; and mitigating effects to biological and cultural resources from site development and environmental cleanup and restoration activities. For example, a total of 470,914 metric tons of contaminated soil from 100 Areas remediation activities were disposed at the Environmental Restoration Disposal Facility (ERDF) during 2004. The Applied Research Center (ARC) at Florida International University (FIU) is supporting the Hanford's site remediation program by analyzing the effectiveness of several soil stabilizers (fixatives) for contamination control during excavation activities. The study is focusing on determining the effects of varying soil conditions, temperature, humidity and wind velocity on the effectiveness of the candidate stabilizers. The test matrix consists of a soil penetration-depth study, wind tunnel experiments for determination of threshold velocity, and temperature and moisture-controlled drying/curing experiments. These three set of experiments are designed to verify performance metrics, as well as provide insight into what fundamental forces are altered by the use of the stabilizer. This paper only presents the preliminary results obtained during wind tunnel experiments using dry Hanford soil samples (with 2.7% moisture by weight). These dry soil samples were exposed to varying wind speeds from 2.22 m/sec to 8.88 m/sec. Furthermore, airborne particulate data was collected for the dry Hanford soil experiments using an aerosol analyzer instrument. (authors)

  13. The MacArthur Competence Assessment Tool-Fitness to Plead: a preliminary evaluation of a research instrument for assessing fitness to plead in England and Wales.

    Science.gov (United States)

    Akinkunmi, Akintunde A

    2002-01-01

    This study concerns the preliminary evaluation of an instrument, the MacArthur Competence Assessment Tool-Fitness to Plead (MacCAT-FP), for assessing competence to stand trial, according to the legal requirements in England and Wales. The purposes of the study were to ascertain whether the instrument can be administered practically to groups of prisoners, both those with mental illness and those without; to examine its internal consistency and interrater reliability; to determine whether it can distinguish between fit and unfit individuals, as judged by expert forensic psychiatrists; and to discover whether it is sensitive to changes over time. The instrument was administered to two groups of remanded prisoners: those transferred to psychiatric units for treatment and those without mental illness. In addition to the MacCAT-FP, scales measuring symptom severity and IQ were administered to all participants. Results suggest that the instrument is practical, with good internal consistency and interrater reliability. The correlation of scores with psychiatrists' opinions as to fitness was 0.77. Scores of unfit patients were significantly different from those of fit individuals. The instrument was able to detect significant differences in scores over time. It is suggested that once the instrument has been further validated for research purposes, it may be developed for clinical application.

  14. Cosmetics chemical composition characterization by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Ana Paula; Pereira, Gustavo Jose; Amaral, Angela Maria; Ferreira, Andrea Vidal, E-mail: ana_allves2008@hotmail.co [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2009-07-01

    Brazil is in the third position in the world's cosmetics market. It is an expanding and growing market where new products and manufacturing processes are in a constant and steady expansion. Therefore, it is mandatory that the composition of the products is well known in order to guarantee safety and quality of daily used cosmetics. The Brazilian National Health Surveillance Agency (ANVISA) has issued a resolution, RDC No. 48, March 16, 2006, which defines a 'List of Substances which can not be used in personal hygiene products, cosmetics and perfumes'. In this work, samples of locally manufactured and imported cosmetics (lipsticks, eye shadows, etc.) were analyzed using the Instrumental Neutron Activation Analysis technique. The samples were irradiated in the TRIGA IPR-R1 reactor of the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN), on a 100kW thermal power, with a thermal neutron fluence rate about 8x10{sup 11}ncm{sup -2}s{sup -1}. The analysis has detected the chemical elements Br, Ba, Ga, Na, K, Sc, Fe, Cr, Zn, Sm, W, La, Rb, Cs, Ta, Ge, Co, U, Ti, V, Cl, Al, Mn and Cu. The concentrations of these elements are on a range from 5 to 3000mug.g{sup -1}. Some chemical elements observed in samples (Cl, Br, Cr, U) are included at ANVISA prohibitive list. (author)

  15. Positron emission tomography: Physics, instrumentation, and image analysis

    International Nuclear Information System (INIS)

    Porenta, G.

    1994-01-01

    Positron emission tomography (PET) is a noninvasive diagnostic technique that permits reconstruction of cross-sectional images of the human body which depict the biodistribution of PET tracer substances. A large variety of physiological PET tracers, mostly based on isotopes of carbon, nitrogen, oxygen, and fluorine is available and allows the in vivo investigation of organ perfusion, metabolic pathways and biomolecular processes in normal and diseased states. PET cameras utilize the physical characteristics of positron decay to derive quantitative measurements of tracer concentrations, a capability that has so far been elusive for conventional SPECT (single photon emission computed tomography) imaging techniques. Due to the short half lives of most PET isotopes, an on-site cyclotron and a radiochemistry unit are necessary to provide an adequate supply of PET tracers. While operating a PET center in the past was a complex procedure restricted to few academic centers with ample resources. PET technology has rapidly advanced in recent years and has entered the commercial nuclear medicine market. To date, the availability of compact cyclotrons with remote computer control, automated synthesis units for PET radiochemistry, high-performance PET cameras, and userfriendly analysis workstations permits installation of a clinical PET center within most nuclear medicine facilities. This review provides simple descriptions of important aspects concerning physics, instrumentation, and image analysis in PET imaging which should be understood by medical personnel involved in the clinical operation of a PET imaging center. (author)

  16. Cosmetics chemical composition characterization by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Alves, Ana Paula; Pereira, Gustavo Jose; Amaral, Angela Maria; Ferreira, Andrea Vidal

    2009-01-01

    Brazil is in the third position in the world's cosmetics market. It is an expanding and growing market where new products and manufacturing processes are in a constant and steady expansion. Therefore, it is mandatory that the composition of the products is well known in order to guarantee safety and quality of daily used cosmetics. The Brazilian National Health Surveillance Agency (ANVISA) has issued a resolution, RDC No. 48, March 16, 2006, which defines a 'List of Substances which can not be used in personal hygiene products, cosmetics and perfumes'. In this work, samples of locally manufactured and imported cosmetics (lipsticks, eye shadows, etc.) were analyzed using the Instrumental Neutron Activation Analysis technique. The samples were irradiated in the TRIGA IPR-R1 reactor of the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN), on a 100kW thermal power, with a thermal neutron fluence rate about 8x10 11 ncm -2 s -1 . The analysis has detected the chemical elements Br, Ba, Ga, Na, K, Sc, Fe, Cr, Zn, Sm, W, La, Rb, Cs, Ta, Ge, Co, U, Ti, V, Cl, Al, Mn and Cu. The concentrations of these elements are on a range from 5 to 3000μg.g -1 . Some chemical elements observed in samples (Cl, Br, Cr, U) are included at ANVISA prohibitive list. (author)

  17. Clinical scoring and instrumental analysis to evaluate skin types.

    Science.gov (United States)

    Mercurio, D G; Segura, J H; Demets, M B A; Maia Campos, P M B G

    2013-04-01

    The biology of the skin is very complex, and there are a number of methods used to classify the different skin types. It is possible to measure or quantify the characteristics of the specific skin types, using a variety of techniques that can objectively evaluate the properties of the skin in a noninvasive manner. To clinically characterize different skin types by dermatological evaluation and biophysical and skin imaging techniques, and to evaluate the relationship between the different characteristics. The study recruited 26 volunteers. Clinical scoring was performed by a dermatologist who classified the volunteers' skin as normal or dry (group 1) and combination or oily (group 2). Objective measurements included skin microrelief, pH, oiliness, water content of the stratum corneum and transepidermal water loss (TEWL). Positive correlations were found between the level of skin oiliness and skin texture obtained from both instrumental analysis and clinical scoring. The combination and oily skin types had higher clinical scores for shine intensity, oiliness and tendency to pigmentation, and also had higher objective scores for sebum secretion, TEWL and roughness. Biophysical and skin imaging techniques are effective tools to help characterize skin type and assist in clinical dermatology. We found that different skin types had different characteristics related to skin microrelief, oiliness and TEWL, and therefore require specific dermatological treatments. © The Author(s) CED © 2013 British Association of Dermatologists.

  18. Instrumental neutron activation analysis of tree rings for dendrochemical studies

    International Nuclear Information System (INIS)

    Schaumloffel, J.C.; Filby, R.H.

    1996-01-01

    Instrumental neutron activation analysis (INAA) was employed to determine zinc, cadmium and potassium concentrations in the growth rings of ponderosa pine (Pinus ponderosa Dougl.) trees growing along the shores of Lake Roosevelt in Washington State, U.S.A. where mineral processing activities have resulted in high burdens of zinc and cadmium in the lake sediments. The tree growing along the contaminated waterway display elevated concentrations of zinc in its growth rings relative to a tree growing along an uncontaminated tributary of Lake Roosevelt. Cadmium concentrations in the growth rings from both sites are similar from 1988 to 1993. Water quality data indicate an increased concentration of cadmium in the lake from 1984 to 1988. The increased concentrations of cadmium in the lake water were reflected in apparent increases in concentrations of cadmium in individual rings of the tree sampled at the contaminated site. This suggests that translocation of cadmium in the sapwood of heartwood-forming species does not occur in the short term, and thus may not be a limiting factor in using trees as environmental monitors for cadmium. In addition, five-year tree ring segments were analyzed and subsequently reanalyzed as individual single-year ring segments. The analytical data obtained for the pooled individual rings are essentially the same as for the five-year segments, demonstrating the utility of NAA for dendrochemical studies. (author). 24 refs., 5 figs., 2 tabs

  19. Analysis of marketing instruments used by domestic organic food producers

    Directory of Open Access Journals (Sweden)

    Vehapi Semir

    2016-01-01

    Full Text Available The overview of previous research results points out to the fact that the majority of the sources related to the organic food marketing belong to the literature based on the research of consumers, with the lack of extensive research of organic food producers. Thus, the results obtained by the quantitative research of organic food producers on the territory of the Republic of Serbia, are presented in this paper. The main marketing mix instruments (4P are in the focus of analysis, as the most beneficial way of determining the success of marketing activities of the organic food producers in Serbia. In order to get a comprehensive idea of the success of the market activity of the producers, the obtained results are explained in regard to the theoretical knowledge of consumer behavior, acquired by an extensive overview of the relevant literature. The research results are significant, both for the producers of organic food, as well as for traders, because they indicate the key elements to improve the placement of organic food products originating in Serbia. As an important contribution of the paper to the topic, recommendations for the development of an appropriate marketing strategy are given in the conclusion.

  20. Instrumental neutron activation analysis of carbonatites from Homa Mountain, Kenya

    International Nuclear Information System (INIS)

    Ohde, S.

    2004-01-01

    Twenty eight (major and trace) elements including eight rare earth elements (REEs) in African carbonatite samples were determined by instrumental neutron activation analysis. The geochemical behavior of trace elements was studied in relation to the order of carbonatite intrusion from C1 to C4 through C2 and C3 at Homa Mountain, Kenya. The enrichment of Mn, Fe, Sr, Ba, Th, U and REE is found in the sixteen carbonatites examined in this study. The general increase in the concentrations of Na, Sc, Mn, Sb, Ba, Th, U and REE occurs from C1 to C4 through C2 and C2c, but C3 carbonatite shows a different pattern. The C3 carbonatite is extraordinarily enriched in Mn, Fe and Ba and is highly enriched in Cr, As, Sb and Th. The chondrite-normalized REE distribution pattern of the C3 carbonatite is not rich in the light REE. Strong fractionation between light and heavy REEs is found in the carbonatites, and moderate fractionation in the two alkalic igneous rock samples. In order to evaluate partitioning of REEs into carbonate, oxide and other mineral fractions, a selective chemical leaching technique on carbonatites was applied and is discussed. (author)

  1. Characterization of Brazilian commercial milks by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Santos, L.G.C.; De Nadai Fernandes, E.A.; Tagliaferro, F.S.; Bacchi, M.A.

    2008-01-01

    Aiming at the determination of toxic and essential elements in Brazilian commercial bovine milk, 25 ultra high temperature (UHT) milk samples were acquired in the local market of Piracicaba, SP. The samples were freeze-dried and analyzed by instrumental neutron activation analysis (INAA) allowing the determination of Br, Ca, Co, Cs, Fe, K, Na, Rb and Zn. When the results were expressed as concentration (mg x l -1 ) no significant differences were found. However, considering the dry matter, results showed a clear difference between the mass fractions (mg x kg -1 d.w.) of skim milk and whole milk for the elements Br, Ca, K, Na, Rb and Zn, indicating that the removal of fat caused a concentration effect in the dry matter of skim milks. Discrepancies were found between the concentrations of Ca and Na measured by INAA and the values informed in the labels. Ca showed variations within 30% for most samples, while concentrations of Na were up to 190% higher than informed values. The sample preparation and the INAA procedure were appropriate for the determination of Br, Ca, Co, Cs, Fe, K, Na, Rb and Zn in milk samples. (author)

  2. Instrumental neutron activation analysis of prehistoric and ancient bone remains

    International Nuclear Information System (INIS)

    Vasidov, A.; Osinskaya, N.S.; Khatamov, Sh.; Rakhmanova, T.

    2008-01-01

    Instrumental neutron activation analysis (INAA) was used to study the element contents in bones of prehistoric dinosaurs and bones of an ancient bear and an archantrop (ancient person), which were found on the territory of Uzbekistan. Concentrations of more than 25 elements were in the range of 0.043-3600 mg/kg. Multielement analyses of bone and soil samples were carried out by INAA using the WWR-SM research nuclear reactor. Results of measurements have shown that in the dinosaurs bones the concentration of the rare earth elements (REEs) were within 280-3200 mg/kg; the uranium content reached a very high value, up to 180 mg/kg, while in soils coating the dinosaurs bones this content was 4.2 mg/kg; in the bones of the archantrop it was 1.53 mg/kg and in the bones of a standard person its amount is less than 0.016 mg/kg. (author)

  3. Geochemistry of single diamond crystals by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Damarupurshad, A.

    1995-02-01

    Neutron activation analysis is probably the most powerful technique, available to date, for the analysis of the trace elements in diamond. In this study the technique of neutron activation analysis has been modified and optimized for the analysis of single, small (0.01-0.5 carat), inclusion-bearing and inclusion-free diamonds. Instrumental neutron activation analysis was used to analyze for up to 40 different elements at the ppb and ppt levels in diamonds from Brazil, South Africa, Colorado and China. The data obtained was used to detect and understand the differences between diamonds from the eclogitic and peridotitic para geneses and between diamonds from the different localities. In this regard, two inter element ratios, i.e. Cr/Sc and Au/Ir ratios were found to be useful. It seems that diamonds from a particular locality or mine have a unique range of Cr/Sc ratios. Furthermore, the identity of the dominant silicate inclusion(s) can be deduced from the Cr/Sc ratio of the diamond, since each type of silicate inclusion has a different range of Cr/Sc ratios. Not only is the Cr/Sc ratio distinctive for silicate inclusions in diamonds, it is also distinctive for minerals co genetic with diamond, such as orange garnet, red garnet, chrome diopside and ortho pyroxene (macrocrysts) which were separated from kimberlites. Sulphide inclusions may also contain detectable quantities of Au and Ir and the ratios of these two elements can also be used to differentiate between diamonds of the two para geneses. Carbon isotope ratios of these eclogitic and peridotitic diamonds were also measured. The comparison of this with the Cr/Sc ratios revealed that the carbon isotope ratios of both para geneses overlap in a narrow range and do not show the clear separations seen with Cr/Sc and Au/Ir ratios. It can be suggested, therefore, on the basis of the suite of 61 diamonds analyzed in this study, that the Cr/Sc and Au/Ir ratios are much more useful tools to distinguish between diamonds

  4. Authentic Performance in the Instrumental Analysis Laboratory: Building a Visible Spectrophotometer Prototype

    Science.gov (United States)

    Wilson, Mark V.; Wilson, Erin

    2017-01-01

    In this work we describe an authentic performance project for Instrumental Analysis in which students designed, built, and tested spectrophotometers made from simple components. The project addressed basic course content such as instrument design principles, UV-vis spectroscopy, and spectroscopic instrument components as well as skills such as…

  5. Instrumental neutron activation analysis, a valuable link in chemical metrology

    International Nuclear Information System (INIS)

    Zeisler, R.; Lindstrom, R.M.; Greenberg, R.R.

    2002-01-01

    Instrumental neutron activation analysis (INAA) is sufficiently versatile to establish a direct link to the amount of substance determined. The inherent quality parameters of INAA, such as being virtually free of blank, having fully accountable effects of matrix and physical form, and operating over a huge range of amounts, allows the comparison of a mole (or its fraction) of a pure element with the amount of substance in the sample analyzed with the same direct relationship as a beam balance provides. Indeed, varieties of this approach are in common use in INAA in the comparator methods of quantitation. To eliminate possible perturbations of the traceability chain as they may occur in common INAA practice, experimental measurements have been set up that only involve the fraction of a mole of the element(s) of interest in form of the pure element, compound or certified standard and the unknown sample. This principle has been used in INAA measurements for certification value assignment of high temperature alloy SRMs. To further demonstrate the performance parameters of INAA, we selected the determination of chromium in SRM 1152a Stainless Steel by direct non-destructive comparison with the pure metal in form of crystalline chromium. The measurements were validated with weighed aliquots of SRM 3112a dried on filter paper pellets. The experimental results do not show deviations beyond the uncertainties of the SRMs (≤ 0.2 % relative), and the assessment of the uncertainty budget indicates that expanded uncertainties of ≤ 0.3 % are achievable. The measurements demonstrate that INAA can meet the CCQM definition of a primary ratio method of analysis

  6. Food-related lifestyles in Singapore: Preliminary testing of a Western European research instrument in Southeast Asia

    DEFF Research Database (Denmark)

    Askegaard, Søren; Brunsø, Karen

    1999-01-01

    The food-related lifestyle instrument developed by the MAPP research group has, up till now, been applied mainly in the context of European cultures. The purpose of the present study is to apply the food-related life style instrument in a new and very different cultural setting, to compare result...

  7. Preliminary results on a new instrument to assess patient motivation for treatment in cognitive-behaviour therapy

    NARCIS (Netherlands)

    Keijsers, G.P.J.; Schaap, C.P.D.R.; Hoogduin, C.A.L.; Hoogsteyns, B.; Kemp, E.C.M. de

    1999-01-01

    The Nijmegen Motivation List 2 (NML2) is a new instrument to assess patient motivation for psychotherapy. A previous version of the instrument was associated with positive treatment outcome in cognitive-behaviour therapy in several studies but its psychometric properties were poor. The present study

  8. The Development of the Planet Formation Concept Inventory: A Preliminary Analysis of Version 1

    Science.gov (United States)

    Simon, Molly; Impey, Chris David; Buxner, Sanlyn

    2018-01-01

    The topic of planet formation is poorly represented in the educational literature, especially at the college level. As recently as 2014, when developing the Test of Astronomy Standards (TOAST), Slater (2014) noted that for two topics (formation of the Solar System and cosmology), “high quality test items that reflect our current understanding of students’ conceptions were not available [in the literature]” (Slater,2014, p. 8). Furthermore, nearly half of ASTR 101 enrollments are at 2 year/community colleges where both instructors and students have little access to current research and models of planet formation. In response, we administered six student replied response (SSR) short answer questions on the topic of planet formation to n = 1,050 students enrolled in introductory astronomy and planetary science courses at The University of Arizona in the Fall 2016 and Spring 2017 semesters. After analyzing and coding the data from the SSR questions, we developed a preliminary version of the Planet Formation Concept Inventory (PFCI). The PFCI is a multiple-choice instrument with 20 planet formation-related questions, and 4 demographic-related questions. We administered version 1 of the PFCI to six introductory astronomy and planetary science courses (n ~ 700 students) during the Fall 2017 semester. We provided students with 7-8 multiple-choice with explanation of reasoning (MCER) questions from the PFCI. Students selected an answer (similar to a traditional multiple-choice test), and then briefly explained why they chose the answer they did. We also conducted interviews with ~15 students to receive feedback on the quality of the questions and clarity of the instrument. We will present an analysis of the MCER responses and student interviews, and discuss any modifications that will be made to the instrument as a result.

  9. Preliminary Analysis of a Submerged Wave Energy Device

    Science.gov (United States)

    Wagner, J. R.; Wagner, J. J.; Hayatdavoodi, M.; Ertekin, R. C.

    2016-02-01

    Preliminary analysis of a submerged wave energy harvesting device is presented. The device is composed of a thin, horizontally submerged plate that is restricted to heave oscillations under the influence of surface waves. The submerged plate is oscillating, and it can be attached to a fixed rotor, or a piston, to harvest the wave energy. A fully submerged wave energy converter is preferred over a surface energy convertor due to its durability and less visual and physical distractions it presents. In this study, the device is subject to nonlinear shallow-water waves. Wave loads on the submerged oscillating plate are obtained via the Level I Green-Naghdi equations. The unsteady motion of the plate is obtained by solving the nonlinear equations of motion. The results are obtained for a range of waves with varying heights and periods. The amplitude and period of plate oscillations are analyzed as functions of the wave parameters and plate width. Particular attention is given to the selection of the site of desired wave field. Initial estimation on the amount of energy extraction from the device, located near shore at a given site, is provided.

  10. Preliminary radiation criteria and nuclear analysis for ETF

    International Nuclear Information System (INIS)

    Engholm, B.A.

    1980-09-01

    Preliminary biological and materials radiation dose criteria for the Engineering Test Facility are described and tabulated. In keeping with the ETF Mission Statement, a key biological dose criterion is a 24-hour shutdown dose rate of 2 mrem/hr on the surface of the outboard bulk shield. Materials dose criteria, which primarily govern the inboard shield design, include 10 9 rads exposure limit to epoxy insulation, 3 x 10 -4 dpa damage to the TF coil copper stabilizer, and a total nuclear heating rate of 5 kW in the inboard TF coils. Nuclear analysis performed during FY 80 was directed primarily at the inboard and outboard bulk shielding, and at radiation streaming in the neutral beam drift ducts. Inboard and outboard shield thicknesses to achieve the biological and materials radiation criteria are 75 cm inboard and 125 cm outboard, the configuration consisting of alternating layers of stainless steel and borated water. The outboard shield also includes a 5 cm layer of lead. NBI duct streaming analyses performed by ORNL and LASL will play a key role in the design of the duct and NBI shielding in FY 81. The NBI aluminum cryopanel nuclear heating rate during the heating cycle is about 1 milliwatt/cm 3 , which is far less than the permissible limit

  11. Preliminary Analysis For Wolsong Par Effects Using ISACC Calculations

    International Nuclear Information System (INIS)

    Song, Yong Mann; Kim, Dong Ha

    2012-01-01

    In the paper, hydrogen control effects using PARs only are analyzed for severe SBO station blackout (SBO) sequences beyond the design basis accidents in WS-1 which are of CANDU6 type reactor. As a computational tool, the latest version of ISAAC4.3 (Integrated Severe Accident Analysis Code for CANDU), which is a fully integrated and lumped severe accident computer code, is used to simulate hydrogen generation and transport inside the reactor building (R/B) before its failure. For the performance of hydrogen removal, the depletion rate equation of K-PAR developed in Korea is applied. In a CANDU reactor, three areas are identified as sources of hydrogen under severe accidents: fuel-coolant interactions in intact channels, suspended fuel or debris interactions in-calandria tank and debris interactions in-calandria vault. The first two origins provide source for the late ('late' terminology is used because it takes more than one day before calandria tank failure) potential hydrogen combustion before calandria tank failure and all the three origins would provide source for the very late potential hydrogen combustion occurring at or after calaria tank failure. If the hydrogen mitigation system fails, the AICC (adiabatic isochoric complete combustion) burning of highly flammable hydrogen may cause Wolsong R/B failure. So hydrogen induced failure possibility is evaluated, using preliminary ISAAC calculations, under several SBO conditions with and without PAR for both late and very late accident periods

  12. Preliminary analysis of accelerated space flight ionizing radiation testing

    Science.gov (United States)

    Wilson, J. W.; Stock, L. V.; Carter, D. J.; Chang, C. K.

    1982-01-01

    A preliminary analysis shows that radiation dose equivalent to 30 years in the geosynchronous environment can be accumulated in a typical composite material exposed to space for 2 years or less onboard a spacecraft orbiting from perigee of 300 km out to the peak of the inner electron belt (approximately 2750 km). Future work to determine spacecraft orbits better tailored to materials accelerated testing is indicated. It is predicted that a range of 10 to the 9th power to 10 to the 10th power rads would be accumulated in 3-6 mil thick epoxy/graphite exposed by a test spacecraft orbiting in the inner electron belt. This dose is equivalent to the accumulated dose that this material would be expected to have after 30 years in a geosynchronous orbit. It is anticipated that material specimens would be brought back to Earth after 2 years in the radiation environment so that space radiation effects on materials could be analyzed by laboratory methods.

  13. Investigation of Sorption and Diffusion Mechanisms, and Preliminary Economic Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bhave, Ramesh R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jubin, Robert Thomas [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Spencer, Barry B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Nair, Sankar [Georgia Inst. of Technology, Atlanta, GA (United States)

    2017-02-01

    This report describes the synthesis and evaluation of molecular sieve zeolite membranes to separate and concentrate tritiated water (HTO) from dilute HTO-bearing aqueous streams. Several monovalent and divalent cation exchanged silico alumino phosphate (SAPO-34) molecular sieve zeolite membranes were synthesized on disk supports and characterized with gas and vapor permeation measurements. The pervaporation process performance was evaluated for the separation and concentration of tritiated water. Experiments were performed using tritiated water feed solution containing tritium at the high end of the range (1 mCi/mL) anticipated in a nuclear fuel processing system that includes both acid and water streams recycling. The tritium concentration was about 0.1 ppm. The permeate was recovered under vacuum. The HTO/H2O selectivity and separation factor calculated from the measured tritium concentrations ranged from 0.99 to 1.23, and 0.83-0.98, respectively. Although the membrane performance for HTO separation was lower than expected, several encouraging observations including molecular sieving and high vapor permeance are reported. Additionally, several new approaches are proposed, such as tuning the sorption and diffusion properties offered by small pore LTA zeolite materials, and cation exchanged aluminosilicates with high metal loading. It is hypothesized that substantially improved preferential transport of tritium (HTO) resulting in a more concentrated permeate can be achieved. Preliminary economic analysis for the membrane-based process to concentrate tritiated water is also discussed.

  14. Preliminary analysis of public dose from CFETR gaseous tritium release

    Energy Technology Data Exchange (ETDEWEB)

    Nie, Baojie [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); University of Science and Technology of China, Hefei, Anhui 230027 (China); Ni, Muyi, E-mail: muyi.ni@fds.org.cn [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Lian, Chao; Jiang, Jieqiong [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China)

    2015-02-15

    Highlights: • Present the amounts and limit dose of tritium release to the environment for CFETR. • Perform a preliminary simulation of radiation dose for gaseous tritium release. • Key parameters about soil types, wind speed, stability class, effective release height and age were sensitivity analyzed. • Tritium release amount is recalculated consistently with dose limit in Chinese regulation for CFETR. - Abstract: To demonstrate tritium self-sufficiency and other engineering issues, the scientific conception of Chinese Fusion Engineering Test Reactor (CFETR) has been proposed in China parallel with ITER and before DEMO reactor. Tritium environmental safety for CFETR is an important issue and must be evaluated because of the huge amounts of tritium cycling in reactor. In this work, different tritium release scenarios of CFETR and dose limit regulations in China are introduced. And the public dose is preliminarily analyzed under normal and accidental events. Furthermore, after finishing the sensitivity analysis of key input parameters, the public dose is reevaluated based on extreme parameters. Finally, tritium release amount is recalculated consistently with the dose limit in Chinese regulation for CFETR, which would provide a reference for tritium system design of CFETR.

  15. Cost risk analysis of radioactive waste management Preliminary study

    International Nuclear Information System (INIS)

    Forsstroem, J.

    2006-12-01

    This work begins with exposition of the basics of risk analysis. These basics are then applied to the Finnish radioactive waste disposal environment in which the nuclear power companies are responsible for all costs of radioactive waste management including longterm disposal of spent fuel. Nuclear power companies prepare cost estimates of the waste disposal on a yearly basis to support the decision making on accumulation of resources to the nuclear waste disposal fund. These cost estimates are based on the cost level of the ongoing year. A Monte Carlo simulation model of the costs of the waste disposal system was defined and it was used to produce preliminary results of its cost risk characteristics. Input data was synthesised by modifying the original coefficients of cost uncertainty to define a cost range for each cost item. This is a suitable method for demonstrating results obtainable by the model but it is not accurate enough for supporting decision making. Two key areas of further development were identified: the input data preparation and identifying and handling of (i.e. eliminating or merging) interacting cost elements in the simulation model. Further development in both of the mentioned areas can be carried out by co-operating with the power companies as they are the sources of the original data. (orig.)

  16. Grid-connected ICES: preliminary feasibility analysis and evaluation. Volume 2. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1977-06-30

    The HEAL Complex in New Orleans will serve as a Demonstration Community for which the ICES Demonstration System will be designed. The complex is a group of hospitals, clinics, research facilities, and medical educational facilities. The five tasks reported on are: preliminary energy analysis; preliminary institutional assessment; conceptual design; firming-up of commitments; and detailed work management plan.

  17. Preliminary safety analysis of molten salt breeder reactor

    International Nuclear Information System (INIS)

    Cheng Maosong; Dai Zhimin

    2013-01-01

    Background: The molten salt reactor is one of the six advanced reactor concepts identified by the Generation IV International Forum as a candidate for cooperative development, which is characterized by remarkable advantages in inherent safety, fuel cycle, miniaturization, effective utilization of nuclear resources and proliferation resistance. ORNL finished the conceptual design of Molten Salt Breeder Reactor (MSBR) based on the design, building and operation of Molten Salt Reactor Experiment (MSRE). Purpose: We attempt to implement the preliminary safety analysis of MSBR in order to provide a reference for the design and optimization of MSBR in the future. Methods: According to the conceptual design of MSBR, a model of safety analysis using point kinetics coupled with the simplified heat transfer mechanism is presented. The model is applied to simulate the transient phenomena of MSBR initiated by an abnormal step reactivity addition and an abnormal ramp reactivity addition at full-power equilibrium condition. Results: The thermal power in the core increases rapidly at the beginning and is accompanied by a rise of the fuel and graphite temperatures after 100, 300, 500 and 600 pcm reactivity addition. The maximum outlet temperature of the fuel in the core is at 1250℃ in 500 pcm reactivity addition, but up to 1350℃ in 600 pcm reactivity addition. The maximum of the power and the temperature are delayed and lower in the ramp reactivity addition rather than in the step reactivity addition. Conclusions: Based on the results, when the reactivity inserted is less than 500 pcm in maximum at full power equilibrium condition, the structural material in Hastelloy-N is not melted and can keep integrity without external control action. And it is necessary to try to avoid inserting a reactivity at short time. (authors)

  18. Conversion Preliminary Safety Analysis Report for the NIST Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Diamond, D. J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Baek, J. S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Hanson, A. L. [Brookhaven National Lab. (BNL), Upton, NY (United States); Cheng, L-Y [Brookhaven National Lab. (BNL), Upton, NY (United States); Brown, N. [Brookhaven National Lab. (BNL), Upton, NY (United States); Cuadra, A. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-01-30

    The NIST Center for Neutron Research (NCNR) is a reactor-laboratory complex providing the National Institute of Standards and Technology (NIST) and the nation with a world-class facility for the performance of neutron-based research. The heart of this facility is the NIST research reactor (aka NBSR); a heavy water moderated and cooled reactor operating at 20 MW. It is fueled with high-enriched uranium (HEU) fuel elements. A Global Threat Reduction Initiative (GTRI) program is underway to convert the reactor to low-enriched uranium (LEU) fuel. This program includes the qualification of the proposed fuel, uranium and molybdenum alloy foil clad in an aluminum alloy, and the development of the fabrication techniques. This report is a preliminary version of the Safety Analysis Report (SAR) that would be submitted to the U.S. Nuclear Regulatory Commission (NRC) for approval prior to conversion. The report follows the recommended format and content from the NRC codified in NUREG-1537, “Guidelines for Preparing and Reviewing Applications for the Licensing of Non-power Reactors,” Chapter 18, “Highly Enriched to Low-Enriched Uranium Conversions.” The emphasis in any conversion SAR is to explain the differences between the LEU and HEU cores and to show the acceptability of the new design; there is no need to repeat information regarding the current reactor that will not change upon conversion. Hence, as seen in the report, the bulk of the SAR is devoted to Chapter 4, Reactor Description, and Chapter 13, Safety Analysis.

  19. Application of instrumental neutron activation analysis and X-ray fluorescence analysis in art pieces investigation

    International Nuclear Information System (INIS)

    Panczyk, E.; Kierzek, J.; Walis, L.; Ligeza, M.

    1996-01-01

    The application of instrumental neutron activation analysis have been shown for the trace element identification in dyes of old painting and other art objects. The recognition of their composition is a important measure for attribution. Also the X-ray fluorescence analysis has been frequently used for examination of art objects. The age determination of the old chinese porcelain is a good example described in the paper. 20 refs, 4 figs

  20. Trace element contents in atmospheric suspended particles: inferences from instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Querol, X.; Alastuey, A.; Lopez-Soler, A.; Boix, A.; Sanfeliu, T.; Martynov, V.V.; Piven, P.I.; Kabina, L.P.; Souschov, P.A.

    1997-01-01

    This study focuses on the determination of trace element concentrations in total suspended particles by instrumental neutron activation analysis (INAA) in two different areas in Northeastern Spain (a rural area influenced by the emissions of a large coal-fired power station, and the urban and industrial areas of Castellon). Total suspended particles were sampled by means of standard MCV high- and medium-volume captors, using cellulose membrane filters of 0.8 and 0.45 μm pore size. Preliminary research was performed on the homogeneous distribution of elements in the sample filters and on the study of blank filters for the calculations of the background average element contents. The results obtained allowed to distinguish different major anthropogenic sources of trace elements in the atmosphere at the sampling sites: (a) Zr, Hf, Sc, U and Th are related to atmospheric pollution derived from the ceramic industry of the Castellon area; (b) As, Cr, Cs, Rb, Sb, Se, Zn are related to traffic and other industrial emission in the Castellon area, and As, Cr, Sb and Zn to power generation emissions in the rural area. (orig.). With 3 figs., 5 tabs

  1. A Preliminary Tsunami vulnerability analysis for Bakirkoy district in Istanbul

    Science.gov (United States)

    Tufekci, Duygu; Lutfi Suzen, M.; Cevdet Yalciner, Ahmet; Zaytsev, Andrey

    2016-04-01

    Resilience of coastal utilities after earthquakes and tsunamis has major importance for efficient and proper rescue and recovery operations soon after the disasters. Vulnerability assessment of coastal areas under extreme events has major importance for preparedness and development of mitigation strategies. The Sea of Marmara has experienced numerous earthquakes as well as associated tsunamis. There are variety of coastal facilities such as ports, small craft harbors, and terminals for maritime transportation, water front roads and business centers mainly at North Coast of Marmara Sea in megacity Istanbul. A detailed vulnerability analysis for Yenikapi region and a detailed resilience analysis for Haydarpasa port in Istanbul have been studied in previously by Cankaya et al., (2015) and Aytore et al., (2015) in SATREPS project. In this study, the methodology of vulnerability analysis under tsunami attack given in Cankaya et al., (2015) is modified and applied to Bakirkoy district of Istanbul. Bakirkoy district is located at western part of Istanbul and faces to the North Coast of Marmara Sea from 28.77oE to 28.89oE. High resolution spatial dataset of Istanbul Metropolitan Municipality (IMM) is used and analyzed. The bathymetry and topography database and the spatial dataset containing all buildings/structures/infrastructures in the district are collated and utilized for tsunami numerical modeling and following vulnerability analysis. The tsunami parameters from deterministically defined worst case scenarios are computed from the simulations using tsunami numerical model NAMI DANCE. The vulnerability assessment parameters in the district according to vulnerability and resilience are defined; and scored by implementation of a GIS based TVA with appropriate MCDA methods. The risk level is computed using tsunami intensity (level of flow depth from simulations) and TVA results at every location in Bakirkoy district. The preliminary results are presented and discussed

  2. ASPECT OF LANGUAGE ON A QUALITATIVE ANALYSIS OF STUDENT’S EVALUATION INSTRUMENT

    Directory of Open Access Journals (Sweden)

    Ismanto Ismanto

    2016-11-01

    Full Text Available This article examined the characteristics of good student’s evaluation instrument. There are at least two requirements that must be met. Those are valid and reliable. The validity of the instrument can be seen from the instrument's ability to measure what should be measured. The fact the existence of the validity of an instrument may be a grain fill, the response process, internal structure, relationship with other variables, and the consequences of the implementation of the charging instrument. Analysis of the content is then known as content validity, i.e. rational analysis of the domain to be measured to determine the representation of each item on the instrument with the ability to be measured. Content validity is submitting pieces of blue print and items of the instrument to the experts to be analyzed quantitatively and qualitatively.

  3. Risk Assessment of Healthcare Waste by Preliminary Hazard Analysis Method

    Directory of Open Access Journals (Sweden)

    Pouran Morovati

    2017-09-01

    Full Text Available Introduction and purpose: Improper management of healthcare waste (HCW can pose considerable risks to human health and the environment and cause serious problems in developing countries such as Iran. In this study, we sought to determine the hazards of HCW in the public hospitals affiliated to Abadan School of Medicine using the preliminary hazard analysis (PHA method. Methods: In this descriptive and analytic study, health risk assessment of HCW in government hospitals affiliated to Abadan School of Medicine (4 public hospitals was carried out by using PHA in the summer of  2016. Results: We noted the high risk of sharps and infectious wastes. Considering the dual risk of injury and disease transmission, sharps were classified in the very high-risk group, and pharmaceutical and chemical and radioactive wastes were classified in the medium-risk group. Sharps posed the highest risk, while pharmaceutical and chemical wastes had the lowest risk. Among the various stages of waste management, the waste treatment stage was the most hazardous in all the studied hospitals. Conclusion: To diminish the risks associated with healthcare waste management in the studied hospitals, adequate training of healthcare workers and care providers, provision of suitable personal protective and transportation equipment, and supervision of the environmental health manager of hospitals should be considered by the authorities.  

  4. A preliminary study on identification of Thai rice samples by INAA and statistical analysis

    Science.gov (United States)

    Kongsri, S.; Kukusamude, C.

    2017-09-01

    This study aims to investigate the elemental compositions in 93 Thai rice samples using instrumental neutron activation analysis (INAA) and to identify rice according to their types and rice cultivars using statistical analysis. As, Mg, Cl, Al, Br, Mn, K, Rb and Zn in Thai jasmine rice and Sung Yod rice samples were successfully determined by INAA. The accuracy and precision of the INAA method were verified by SRM 1568a Rice Flour. All elements were found to be in a good agreement with the certified values. The precisions in term of %RSD were lower than 7%. The LODs were obtained in range of 0.01 to 29 mg kg-1. The concentration of 9 elements distributed in Thai rice samples was evaluated and used as chemical indicators to identify the type of rice samples. The result found that Mg, Cl, As, Br, Mn, K, Rb, and Zn concentrations in Thai jasmine rice samples are significantly different but there was no evidence that Al is significantly different from concentration in Sung Yod rice samples at 95% confidence interval. Our results may provide preliminary information for discrimination of rice samples and may be useful database of Thai rice.

  5. Introduction to Instrumental Analysis of Water Pollutants. Training Manual.

    Science.gov (United States)

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This course is designed for those requiring an introduction to instruments commonly used in water pollution analyses. Examples are: pH, conductivity, dissolved oxygen meters, spectrophotometers, turbidimeters, carbon analyzer, and gas chromatographs. Students should have a basic knowledge of analytical chemistry. (CO)

  6. A Comparison of seismic instrument noise coherence analysis techniques

    Science.gov (United States)

    Ringler, A.T.; Hutt, C.R.; Evans, J.R.; Sandoval, L.D.

    2011-01-01

    The self-noise of a seismic instrument is a fundamental characteristic used to evaluate the quality of the instrument. It is important to be able to measure this self-noise robustly, to understand how differences among test configurations affect the tests, and to understand how different processing techniques and isolation methods (from nonseismic sources) can contribute to differences in results. We compare two popular coherence methods used for calculating incoherent noise, which is widely used as an estimate of instrument self-noise (incoherent noise and self-noise are not strictly identical but in observatory practice are approximately equivalent; Holcomb, 1989; Sleeman et al., 2006). Beyond directly comparing these two coherence methods on similar models of seismometers, we compare how small changes in test conditions can contribute to incoherent-noise estimates. These conditions include timing errors, signal-to-noise ratio changes (ratios between background noise and instrument incoherent noise), relative sensor locations, misalignment errors, processing techniques, and different configurations of sensor types.

  7. Validation of a Visionary Leadership Attitude Instrument Using Factor Analysis.

    Science.gov (United States)

    LeSourd, Sandra J.; And Others

    Findings from a study to develop and validate an instrument for the measurement of principals' attitudes toward visionary leadership are presented in this paper. Two leadership styles--visionary and managerial--were measured by a 35-item five-point Likert attitude scale. Questionnaires mailed to a random sample of 250 K-12 Nebraska and 250…

  8. Cost analysis of small hydroelectric power plants components and preliminary estimation of global cost

    International Nuclear Information System (INIS)

    Basta, C.; Olive, W.J.; Antunes, J.S.

    1990-01-01

    An analysis of cost for each components of Small Hydroelectric Power Plant, taking into account the real costs of these projects is shown. It also presents a global equation which allows a preliminary estimation of cost for each construction. (author)

  9. SEM analysis of defects and wear on Ni-Ti rotary instruments.

    Science.gov (United States)

    Arantes, Werington Borges; da Silva, Celso Monteiro; Lage-Marques, José Luiz; Habitante, Sandramarcia; da Rosa, Luiz Carlos Laureano; de Medeiros, João Marcelo Ferreira

    2014-01-01

    SEM analysis of endodontic instruments from a Ni-Ti rotary system was assessed, before and after using them, considering their defects and deformations. Twenty Twisted File®, BioRąCe®, Mtwo®, and EndoWave® instruments were micrographed at 190× magnification. The files were washed and micrographed again to view alterations as to the presence or absence of irregular edges, grooves, microcavities, and scraping. Simulated root canal preparations were performed using these instruments. The instruments were cleaned and received a microscopic analysis after being used five times. After analysis tests were tested using Fisher's exact test and Kappa to evaluate the concordance among examiners. There was a statistically significant difference with respect to deformations between Twisted File® and other instruments (p  0.05). All Twisted File® instruments showed the same defects; however damage were lower than those found in BioRace® and Mtwo®. The Endowave® did not show the same defects. In accordance with the data we conclude that the presence of defects was higher in Twisted File® instruments as the instruments and BioRace® Mtwo® brand, the defect rate was smaller and Endowave® instruments had no defects. Regarding the presence of wear after five uses among the groups all instruments showed changes in their cutting blades. © 2014 Wiley Periodicals, Inc.

  10. Instrumentation requirements for the ESF thermomechanical experiments

    International Nuclear Information System (INIS)

    Pott, J.; Brechtel, C.E.

    1992-01-01

    In situ thermomechanical experiments are planned as part of the Yucca Mountain Site Characterization Project that require instruments to measure stress and displacement at temperatures that exceed the typical specifications of existing geotechnical instruments. A high degree of instrument reliability will also be required to satisfy the objectives of the experiments, therefore a study was undertaken to identify areas where improvement in instrument performance was required. A preliminary list of instruments required for the experiments was developed, based on existing test planning and analysis. Projected temperature requirements were compared to specifications of existing instruments to identify instrumentation development needs. Different instrument technologies, not currently employed in geotechnical instrumentation, were reviewed to identify potential improvements of existing designs for the high temperature environment. Technologies with strong potentials to improve instrument performance with relatively high reliability include graphite fiber composite materials, fiber optics, and video imagery

  11. The Organic Food Market and Marketing Initiatives in Europe: a Preliminary Analysis

    DEFF Research Database (Denmark)

    Kristensen, Niels Heine; Nielsen, Thorkild; Bruselius-Jensen, Maria Louisa

    2003-01-01

    Kristensen NH, Nielsen T, Bruselius-Jensen M, Scheperlen-Bøgh P, Beckie M, Foster C, Midmore P, Padel S (2002): The Organic Food Market and Marketing Initiatives in Europe: a Preliminary Analysis. Final Report to the EU Commission......Kristensen NH, Nielsen T, Bruselius-Jensen M, Scheperlen-Bøgh P, Beckie M, Foster C, Midmore P, Padel S (2002): The Organic Food Market and Marketing Initiatives in Europe: a Preliminary Analysis. Final Report to the EU Commission...

  12. Oxygenates in automotive fuels. Consequence analysis - preliminary study

    International Nuclear Information System (INIS)

    Brandberg, Aa.; Saevbark, B.

    1994-01-01

    Oxygenates is used in gasoline due to several reasons. They are added as high-octane components in unleaded gasoline and as agents to reduce the emission of harmful substances. Oxygenates produced from biomass might constitute a coming market for alternative fuels. This preliminary study describes the prerequisites and consequences of such an oxygenate utilization. 39 refs, 9 figs, 5 tabs

  13. Analysis Brazilian preference shares: financial liabilities or equity instruments?

    OpenAIRE

    Diana Lucia de Almeida; Patricia de Souza Costa; Eliseu Martins

    2016-01-01

    The Brazilian preference shares, in general, except when they present specific features, such as mandatory redemption and cumulative dividends, meet the accounting definition of equity instruments. However, the scientific literature believes that those shares that do not have discretion to avoid the delivery of cash must be classified as financial liabilities. In a context in which remain differences of understanding of their proper accounting treatment, the following question arises: pre...

  14. Analysis of medicinal plants and soil sample from Haridwar region by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Maharia, R.S.; Dutta, R.K.; Acharya, R.; Reddy, A.V.R.

    2009-01-01

    Samples of leaves and stems of four medicinal plants namely Kalmegh, Amaltas, Moalshri, and Arusa were analysed by Instrumental Neutron Activation Analysis. Soil from same location was analyzed. Though concentrations of many elements were determined in the plant samples, results of selected elements namely Na, K, Mn, Fe, Co, Cr, Zn and As are discussed in this paper. The results show that all medicinal plants analyzed have lower elemental contents except Zn compared to the soil. (author)

  15. Neutron activation analysis as applied to instrumental analysis of trace elements from seawater

    International Nuclear Information System (INIS)

    Boniforti, R.; Moauro, A.; Madaro, M.

    1983-01-01

    Particulate matter collected from the coastal area delimited by the mouth of the river Volturno and the Sabaudia lake has been analyzed by instrumental neutron activation analysis for its content of twenty-two trace elements. The results for surface water and bottom water are reported separately, thus evidencing the effect of sampling depth on the concentration of many elements. The necessity of accurately 'cleaning' the filters before use is stressed

  16. [Management of cytostatic drugs by nurses: analysis of preliminary results].

    Science.gov (United States)

    Bilski, Bartosz

    2004-01-01

    Cytostatic drugs pose a quite specific occupational risk to health care workers. There is a wide range of potential harmful effects, including remote effects, exerted by this group of drugs. In Polish and international regulations, standards of work safety and hygiene concerning these substances are clearly defined. Nevertheless working conditions in Polish health care institutions are now mostly influenced by economic and organizational problems, which may also be reflected in the compliance with the work safety rules. This paper presents a preliminary analysis of subjective assessment of practice with regard to the management of cytostatics reported by nurses, an occupational group mostly exposed to these substances. The study was carried out at hospital departments in the Warmińsko-Mazurskie Voivodship, where exposure of the staff to these drugs was observed. The study covered the whole nursing staff exposed. Completed questionnaires were obtained from 60 nurses, aged +/- 32 years (20-54 years) with job seniority +/- 8 years (2-18), including 58 nurses with secondary education and two university graduates. Undergraduate education did not develop in respondents skills to work with cytostatics. There is a need to increase the involvement of nursing schools, research institutes and teaching hospitals in the improvement of vocational training of nurses working with cytostatic drugs. To this end, all nurses should be covered with the obligatory training how to handle this group of drugs. The respondents reported that they had acquired their knowledge and experience of managing cytostatics in their work and during training organized at workplace. Despite the acquired knowledge and experience the interviewed nurses did not always comply with work safety and hygiene regulations. The problem of exposure to cytostatic drugs in the form of tablets was most frequently neglected. Some of the nurses were additionally exposed to ionizing radiation. Shortage of the nursing

  17. Virtual Instruments for the Circuit Analysis with Interactive Parameter Modification

    Directory of Open Access Journals (Sweden)

    Eberhard Stefan Brenner

    2006-08-01

    Full Text Available Abstract—The contribution presents the possibilities of LabVIEW in the special application as formula interpreter by using of the formula node. The main advantage is the immediate presentation of results in case of a parameter modification. The presentation of the time behaviour, the calculation of characteristic values and curves for typical examples of power electronics and control engineering are shown. Index Terms—Education; Formula Interpretation; LabVIEW; Power Electronics; Virtual Instruments

  18. Rare earths analysis of rock samples by instrumental neutron activation analysis, internal standard method

    International Nuclear Information System (INIS)

    Silachyov, I.

    2016-01-01

    The application of instrumental neutron activation analysis for the determination of long-lived rare earth elements (REE) in rock samples is considered in this work. Two different methods are statistically compared: the well established external standard method carried out using standard reference materials, and the internal standard method (ISM), using Fe, determined through X-ray fluorescence analysis, as an element-comparator. The ISM proved to be the more precise method for a wide range of REE contents and can be recommended for routine practice. (author)

  19. Toenail elemental analysis of Korean young adults by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Lee, O.

    2016-01-01

    The element contents in toenail clippings of healthy Korean young adults were measured using an instrumental neutron activation analysis. The average contents of elements such as Na, K, Cl, Ca, Fe, Se, and Zn are 449, 474, 1024, 1677, 66, 0.7 and 94 mg/kg in men, whereas those contents in women respectively 332, 476, 836, 1097, 66, 0.8 and 104 mg/kg. The correlation analysis of toenail elements with chronic disease risks showed positive associations between Na and serum HDL-cholesterol, blood pressure, and negative associations between Se and Hs-CRP, between Zn and hemoglobin level. (author)

  20. Overpowering posterior lumbar instrumentation and fusion with hyperlordotic anterior lumbar interbody cages followed by posterior revision: a preliminary feasibility study.

    Science.gov (United States)

    Kadam, Abhijeet; Wigner, Nathan; Saville, Philip; Arlet, Vincent

    2017-12-01

    OBJECTIVE The authors' aim in this study was to evaluate whether sagittal plane correction can be obtained from the front by overpowering previous posterior instrumentation and/or fusion with hyperlordotic anterior lumbar interbody fusion (ALIF) cages in patients undergoing revision surgery for degenerative spinal conditions and/or spinal deformities. METHODS The authors report their experience with the application of hyperlordotic cages at 36 lumbar levels for ALIFs in a series of 20 patients who underwent revision spinal surgery at a single institution. Included patients underwent staged front-back procedures: ALIFs with hyperlordotic cages (12°, 20°, and 30°) followed by removal of posterior instrumentation and reinstrumentation from the back. Patients were divided into the following 2 groups depending on the extent of posterior instrumentation and fusion during the second stage: long constructs (≥ 6 levels with extension into thoracic spine and/or pelvis) and short constructs (lumbar lordosis increased from 44.3° to 59.8° (p lumbar levels that have pseudarthrosis from the previous posterior spinal fusion. Meticulous selection of levels for ALIF is crucial for safely and effectively performing this technique.

  1. Preliminary Analysis of Helicopter Options to Support Tunisian Counterterrorism Operations

    Science.gov (United States)

    2016-04-27

    helicopters from Sikorsky to fulfill a number of roles in counterterrorism operations. Rising costs and delays in delivery raised the question of...whether other cost-effective options exist to meet Tunisia’s helicopter requirement. Approach Our team conducted a preliminary assessment of...alternative helicopters for counterterrorism air assault missions. Any decision to acquire an aircraft must consider many factors, including technical

  2. Bias and Bias Correction in Multi-Site Instrumental Variables Analysis of Heterogeneous Mediator Effects

    Science.gov (United States)

    Reardon, Sean F.; Unlu, Faith; Zhu, Pei; Bloom, Howard

    2013-01-01

    We explore the use of instrumental variables (IV) analysis with a multi-site randomized trial to estimate the effect of a mediating variable on an outcome in cases where it can be assumed that the observed mediator is the only mechanism linking treatment assignment to outcomes, as assumption known in the instrumental variables literature as the…

  3. Análise da versão espanhola do Sport Satisfaction Instrument (SSI adaptado à Educação Física Analysis of the Spanish version of the Sport Satisfaction Instrument (SSI adapted to Physical Education

    Directory of Open Access Journals (Sweden)

    Antonio Granero-Gallegos

    2013-03-01

    Full Text Available O objetivo deste estudo foi analisar as propriedades psicométricas do Sport Satisfation Instrument (SSI adaptado para a Educação Física (EF por meio de uma análise fatorial exploratória da estrutura bidimensional do instrumento em uma amostra espanhola. Com isso, buscou-se determinar, de maneira preliminar, se o SSI constitui um instrumento válido e fiável para ser utilizado em futuras pesquisas. O instrumento foi elaborado em um modelo teórico de dois fatores: Satisfação/Diversão e Tédio. A amostra constituiu-se de um total de 224 alunos de secundária entre 12 e 19 anos. A versão [espanhola] do instrumento adaptado para a EF demonstrou níveis aceitáveis de consistência interna.The objective of this study was to analyze the psychometric properties of Sport Satisfaction Instrument (SSI adapted physical education (PE using exploratory factor analysis of the dimensional structure of the instrument in a Spanish sample. It was intended to determine, on a preliminary basis, whether it constitutes a valid and reliable for use in future research. Was administered to a total of 224 high school students 12 to 19 years. This analysis supports the hypothesized theoretical model of two factors (satisfaction / fun and boredom. The Spanish version of the instrument for PE showed acceptable levels of internal consistency.

  4. Validation of virtual instrument for data analysis in metrology of time and frequency

    International Nuclear Information System (INIS)

    Jordao, Bruno; Quaresma, Daniel; Rocha, Pedro; Carvalho, Ricardo; Peixoto, Jose Guilherme

    2016-01-01

    Commercial Software (CS) for collection, analysis and plot time and frequency data plots are being increasingly used in reference laboratories worldwide. With this, it has greatly improved the results of calculations of uncertainty for these values. We propose the creation of a collection of software and data analysis using Virtual Instruments (VI) developed the Primary Laboratory Time and frequency of the National Observatory - ON and validation of this instrument. To validate the instrument developed, it made a comparative analysis between the results obtained (VI) with the results obtained by (CS) widely used in many metrology laboratories. From these results we can conclude that there was equivalence between the analyzed data. (author)

  5. Preliminary Geologic/spectral Analysis of LANDSAT-4 Thematic Mapper Data, Wind River/bighorn Basin Area, Wyoming

    Science.gov (United States)

    Lang, H. R.; Conel, J. E.; Paylor, E. D.

    1984-01-01

    A LIDQA evaluation for geologic applications of a LANDSAT TM scene covering the Wind River/Bighorn Basin area, Wyoming, is examined. This involves a quantitative assessment of data quality including spatial and spectral characteristics. Analysis is concentrated on the 6 visible, near infrared, and short wavelength infrared bands. Preliminary analysis demonstrates that: (1) principal component images derived from the correlation matrix provide the most useful geologic information. To extract surface spectral reflectance, the TM radiance data must be calibrated. Scatterplots demonstrate that TM data can be calibrated and sensor response is essentially linear. Low instrumental offset and gain settings result in spectral data that do not utilize the full dynamic range of the TM system.

  6. Preliminary homogeneity study of in-house reference material using neutron activation analysis and X-ray fluorescence

    International Nuclear Information System (INIS)

    Gras, N.; Munoz, L.; Cassorla, V.; Castillo, P.

    1993-01-01

    Although many biological reference materials for quality control of trace element analysis are commercially available, there is still a need for additional local materials for special matrices. In the Latin American region a preliminary study has been commenced involving analytical strategies for the characterization of in-house reference material. A biological sample, prepared in Brazil, constitutes the first regional attempt to prepare reference material. It was analyzed by neutron activation analysis (NAA) and X-ray fluorescence (XRF) to verify its homogeneity. The determination of the trace elements and certain major elements was carried out by instrumental NAA. Trace elements such as Cd, Mn, Mo and Cu were determined using NAA with radiochemical separations to improve the sensitivity and precision. XRF was applied only to major constituents and some trace elements with concentration of more than 10 μg/g. From a total of 18 elements analyzed, only Fe, Cr and Sc were not homogeneously distributed. (orig.)

  7. Protective Alternatives of SMR against Extreme Threat Scenario – A Preliminary Risk Analysis

    International Nuclear Information System (INIS)

    Shohet, I.M.; Ornai, D.; Gal, E.; Ronen, Y.; Vidra, M.

    2014-01-01

    The article presents a preliminary risk analysis of the main features in NPP (Nuclear Power Plant) that includes SMR - Small and Modular Reactors, given an extreme threat scenario. A review of the structure and systems of the SMR is followed by systematic definitions and analysis of the threat scenario to which a preliminary risk analysis was carried out. The article outlines the basic events caused by the referred threat scenario, which had led to possible failure mechanisms according to FTA (Fault-Tree-Analysis),critical protective circuits, and todetecting critical topics for the protection and safety of the reactor

  8. Thermal Hydraulic Analysis of K-DEMO Single Blanket Module for Preliminary Accident Analysis using MELCOR

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Sung Bo; Bang, In Cheol [UNIST, Ulsan (Korea, Republic of)

    2016-05-15

    To develop the Korean fusion commercial reactor, preliminary design concept for K-DEMO (Korean fusion demonstration reactor) has been announced by NFRI (National Fusion Research Institute). This pre-conceptual study of K-DEMO has been introduced to identify technical details of a fusion power plant for the future commercialization of fusion reactor in Korea. Before this consideration, to build the K-DEMO, accident analysis is essential. Since the Fukushima accident, which is severe accident from unexpected disaster, safety analysis of nuclear power plant has become important. The safety analysis of both fission and fusion reactors is deemed crucial in demonstrating the low radiological effect of these reactors on the environment, during severe accidents. A risk analysis of K-DEMO should be performed, as a prerequisite for the construction of a fusion reactor. In this research, thermal-hydraulic analysis of single blanket module of K-DEMO is conducted for preliminary accident analysis for K-DEMO. Further study about effect of flow distributer is conducted. The normal K-DEMO operation condition is applied to the boundary condition and simulated to verify the material temperature limit using MELCOR. MELCOR is fully integrated, relatively fast-running code developed by Sandia National Laboratories. MELCOR had been used for Light Water Reactors and fusion reactor version of MELCOR was developed for ITER accident analysis. This study shows the result of thermal-hydraulic simulation of single blanket module with MELCOR which is severe accident code for nuclear fusion safety analysis. The difference of mass flow rate for each coolant channel with or without flow distributer is presented. With flow distributer, advantage of broadening temperature gradient in the K-DEMO blanket module and increase mass flow toward first wall is obtained. This can enhance the safety of K-DEMO blanket module. Most 13 .deg. C temperature difference in blanket module is obtained.

  9. ANALYSIS OF OPERATING INSTRUMENT LANDING SYSTEM ACCURACY UNDER SIMULATED CONDITIONS

    Directory of Open Access Journals (Sweden)

    Jerzy MERKISZ

    2017-03-01

    Full Text Available The instrument landing system (ILS is the most popular landing aid in the world. It is a distance-angled support system for landing in reduced visibility, while its task is the safe conduct of the aircraft from the prescribed course landing on the approach path. The aim of this study is to analyse the correctness of the ILS in simulated conditions. The study was conducted using a CKAS MotionSim5 flight simulator in the Simulation Research Laboratory of the Institute of Combustion Engines and Transport at Poznan University of Technology. With the advancement of technical equipment, it was possible to check the operation of the system in various weather conditions. Studies have shown that the impact of fog, rain and snow on the correct operation of the system is marginal. Significant influence has been observed, however, during landing in strong winds.

  10. Design of Simple Instrumentation System for the Quality Analysis of Milk (Casein Analysis

    Directory of Open Access Journals (Sweden)

    V. G. Sangam

    2010-08-01

    Full Text Available This paper describes the design of a simple instrumentation system for the analysis of casein concentration in the milk. Casein is one of the major constituent of milk and its concentration describes the quality of the milk. Normally casein is analyzed by conventional analytical methods or by using Spectrophotometric methods. Here an attempt has been made to develop a simple portable system using optical instrumentation technique. The objective of the developed system is the real time analysis of the casein concentration of the milk at the field. The system involves UV light source, UV filter, cuvette, photo detector, display unit, data Acquisition Card (DAC as peripheral with USB port. Appropriate program has been developed in visual studio 6 and turbo C. Repeated number of real time analysis was carried out for different samples of milk; the results obtained are in excellent agreement with the amount determined by standard conventional methods with an accuracy of ±1.5 %, and the response time is within 100 seconds. This system can be used in the field for the quality analysis of milk as an independent unit and can also be interfaced to PC with USB port. The system has good accuracy, less response time and low cost.

  11. The apparent source size of type III radio bursts: Preliminary results by the STEREO/WAVES instruments

    Czech Academy of Sciences Publication Activity Database

    Krupař, Vratislav; Maksimovic, M.; Santolík, Ondřej; Cecconi, B.; Nguyen, Q. N.; Hoang, S.; Goetz, K.

    2010-01-01

    Roč. 1216, č. 1 (2010), s. 284-287 ISSN 0094-243X. [International Solar Wind Conference /12./. Saint-Milo, 21.06.2009-26.06.2009] R&D Projects: GA ČR GAP205/10/2279; GA AV ČR IAA301120601; GA MŠk ME09107 Institutional research plan: CEZ:AV0Z30420517 Keywords : WAVES Instrument * Solar Radio Emissions * Singular Value Decomposition technique Subject RIV: BL - Plasma and Gas Discharge Physics

  12. Antares: preliminary demonstrator results

    International Nuclear Information System (INIS)

    Kouchner, A.

    2000-05-01

    The ANTARES collaboration is building an undersea neutrino telescope off Toulon (Mediterranean sea) with effective area ∼ 0.1 km 2 . An extensive study of the site properties has been achieved together with software analysis in order to optimize the performance of the detector. Results are summarized here. An instrumented line, linked to shore for first time via an electro-optical cable, has been immersed late 1999. The preliminary results of this demonstrator line are reported. (author)

  13. X-Ray Diffraction and Fluorescence Instrument for Mineralogical Analysis at the Lunar Surface, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop LUNA, a compact and lightweight X-Ray Diffraction (XRD) / X-Ray Fluorescence (XRF) instrument for mineralogical analysis of regolith, rock...

  14. X-Ray Diffraction and Fluorescence Instrument for Mineralogical Analysis at the Lunar Surface, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a compact and lightweight X-Ray Diffraction (XRD) / X-Ray Fluorescence (XRF) instrument for analysis of mineralogical composition of regolith,...

  15. Determination of toxic elements in tobacco by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Yaprak, G.; Cam, N.F.

    1998-01-01

    The concentration of toxic elements in the tobacco of six different brands of domestic and two brands of imported cigarettes heavily smoked in Turkey were determined using instrumental neutron activation analysis (INAA)

  16. Lessons Learned From the Analysis of the SAFOD Downhole Instrument Package.

    Science.gov (United States)

    Johnson, Wade; Mencin, David; Mattioli, Glen

    2013-04-01

    In September of 2008 a downhole instrument package (DIP) consisting of a string of seismometers and tilt meters in isolated pressure vessels (PODs) was installed in the SAFOD main borehole. This package was designed to protect the sensors from the corrosive borehole environment and to operate for two years. The SAFOD borehole is not sealed at the bottom allowing borehole gasses and fluids infiltratration. Previous short-term installations of instruments in the SAFOD main borehole had also failed as a result of corrosion of the wireline cable head. The average failure time for these installations was two weeks. The use of stainless steel tubing connected to the pressure vessels through gas tight fittings was designed to block borehole fluid and gas infiltration of the individual instruments within the PODs. Unfortunately, the DIP completely failed within a month of its installation. In October of 2010, the DIP was removed from the borehole and a failure analysis was performed. This analysis involved to following steps: 1. Analysis of data to understand timeline of failure 2. Remove instrument safely, maintaining integrity of spliced section and documenting any external clues. Test instrument at surface 3. Open PODs in a way that allows for sampling and avoids damaging instruments. 4. Chemical analysis of fluids recovered from splices and PODs. 5. Instrument failure analysis by the instrument manufacturers. The analysis found that there were several design flaws in the DIP. This included the use of motor oil to take up air space in the individual PODs, use of a large number of gas tight seals, lack of internal seals, poorly done solder joints, use of non-temperature rated sensors, and lack of management oversight. The lessons learned from the attempts to instrument the SAFOD borehole are critical to the success of future deep borehole projects.

  17. Instrumental neutron activation analysis as a routine method for rock analysis

    International Nuclear Information System (INIS)

    Rosenberg, R.J.

    1977-06-01

    Instrumental neutron activation methods for the analysis of geological samples have been developed. Special emphasis has been laid on the improvement of sensitivity and accuracy in order to maximize tha quality of the analyses. Furthermore, the procedures have been automated as far as possible in order to minimize the cost of the analysis. A short review of the basic literature is given followed by a description of the principles of the method. All aspects concerning the sensitivity are discussed thoroughly in view of the analyst's possibility of influencing them. Experimentally determined detection limits for Na, Al, K, Ca, Sc, Cr, Ti, V, Mn, Fe, Ni, Co, Rb, Zr, Sb, Cs, Ba, La, Ce, Nd, Sm, Eu, Gd, Tb, Dy, Yb, Lu, Hf, Ta, Th and U are given. The errors of the method are discussed followed by actions taken to avoid them. The most significant error was caused by flux deviation, but this was avoided by building a rotating sample holder for rotating the samples during irradiation. A scheme for the INAA of 32 elements is proposed. The method has been automated as far as possible and an automatic γ-spectrometer and a computer program for the automatic calculation of the results are described. Furthermore, a completely automated uranium analyzer based on delayed neutron counting is described. The methods are discussed in view of their applicability to rock analysis. It is stated that the sensitivity varies considerably from element to element and instrumental activation analysis is an excellent method for the analysis of some specific elements like lanthanides, thorium and uranium but less so for many other elements. The accuracy is good varying from 2% to 10% for most elements. Instrumental activation analysis for most elements is rather an expensive method there being, however, a few exceptions. The most important of these is uranium. The analysis of uranium by delayed neutron counting is an inexpensive means for the analysis of large numbers of samples needed for

  18. Intelligent data-acquisition instrumentation for special nuclear material assay data analysis

    International Nuclear Information System (INIS)

    Ethridge, C.D.

    1980-01-01

    The Detection, Surveillance, Verification, and Recovery Group of the Los Alamos Scientific Laboratory Energy Division/Nuclear Safeguards Programs is now utilizing intelligent data-acquisition instrumentation for assay data analysis of special nuclear material. The data acquisition and analysis are enabled by the incorporation of a number-crunching microprocessor sequenced by a single component microcomputer. Microcomputer firmware establishes the capability for processing the computation of several selected functions and also the ability of instrumentation self-diagnostics

  19. Comparison of textural atributes of selected meat sausages using instrumental analysis

    OpenAIRE

    Vladimír Vietoris; Ľubomír Lopašovský; Peter Zajác; Jozef Čurlej; Jozef Čapla

    2013-01-01

    The aim of the study was to compare textural atributes of selected meat sausages using instrumental analysis. For this purpose, seven different meat sausage samples were treated by instrumental analysis, by the use of Warner-Bratzler probe,  to find differences for two selected textural parameter firmness and work of shear. As expected, various values of mentioned atributes were obtained for different samples tested in fresh stage and after storage under controlled conditions (48 hrs., 30 °...

  20. Multielement analysis of Nigerian chewing sticks by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Asubiojo, O.I.; Guinn, V.P.

    1982-01-01

    In Nigeria, various parts of various species of native plants have long been used for dental hygiene, with reportedly considerable effectiveness. These materials are known as 'chewing sticks'. This study was an effort to ascertain whether any unusual trace element concentrations might be present in Nigerian chewing sticks. Results are presented for 17 elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Mn, Fe, Co, Zn, Br, Cs, La, Sm, Au) detected and measured in 12 species of such plants, via instrumental thermal-neutron activation analysis. (author)

  1. Multielement analysis of Nigerian chewing sticks by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Asubiojo, O.I.; Guinn, V.P. (California Univ., Irvine (USA). Dept. of Chemistry); Okunuga, A. (California Polytechnic Univ., Pomona, CA (USA))

    1982-01-01

    In Nigeria, various parts of various species of native plants have long been used for dental hygiene, with reportedly considerable effectiveness. These materials are known as 'chewing sticks'. This study was an effort to ascertain whether any unusual trace element concentrations might be present in Nigerian chewing sticks. Results are presented for 17 elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Mn, Fe, Co, Zn, Br, Cs, La, Sm, Au) detected and measured in 12 species of such plants, via instrumental thermal-neutron activation analysis.

  2. Elemental analysis of soil and hair sample by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Quraishi, Shamshad Begum; Moon, Jong Hwa; Kim, Sun Ha; Baek, Sung Yeoil; Kang, Sang Hoon; Lim, Jong Myoung; Cho, Hyun Je; Kim, Young Jin

    2004-03-01

    Myanmar soil sample was analyzed by using the instrumental neutron activation analysis. The elemental concentrations in the sample, altogether 34 elements, Al As, Ba, Ce, Co, Cr, Cs, Eu, Fe, Ga, Gd, Hf, Ir, K, La, Lu, Mn, Na, Nd, Rb, Sb, Sc, Se, Sm, Th, Ti, V, Yb, Zn and Zr were determined. The concentration of 17 elements (Al, Au, Br, Ca, Cl, Cr, Cu, Co, Fe, Hg, K, Na, Mn, Mg, Sb, Se, Zn) in human hair samples were determined by INAA For quality control of analytical method, certified reference material was used

  3. Elemental analysis of soil and hair sample by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yong Sam; Quraishi, Shamshad Begum; Moon, Jong Hwa; Kim, Sun Ha; Baek, Sung Yeoil; Kang, Sang Hoon; Lim, Jong Myoung; Cho, Hyun Je; Kim, Young Jin

    2004-03-01

    Myanmar soil sample was analyzed by using the instrumental neutron activation analysis. The elemental concentrations in the sample, altogether 34 elements, Al As, Ba, Ce, Co, Cr, Cs, Eu, Fe, Ga, Gd, Hf, Ir, K, La, Lu, Mn, Na, Nd, Rb, Sb, Sc, Se, Sm, Th, Ti, V, Yb, Zn and Zr were determined. The concentration of 17 elements (Al, Au, Br, Ca, Cl, Cr, Cu, Co, Fe, Hg, K, Na, Mn, Mg, Sb, Se, Zn) in human hair samples were determined by INAA For quality control of analytical method, certified reference material was used.

  4. Preliminary Hazard Analysis applied to Uranium Hexafluoride - UF6 production plant

    International Nuclear Information System (INIS)

    Tomzhinsky, David; Bichmacher, Ricardo; Braganca Junior, Alvaro; Peixoto, Orpet Jose

    1996-01-01

    The purpose of this paper is to present the results of the Preliminary hazard Analysis applied to the UF 6 Production Process, which is part of the UF 6 Conversion Plant. The Conversion Plant has designed to produce a high purified UF 6 in accordance with the nuclear grade standards. This Preliminary Hazard Analysis is the first step in the Risk Management Studies, which are under current development. The analysis evaluated the impact originated from the production process in the plant operators, members of public, equipment, systems and installations as well as the environment. (author)

  5. Survival Analysis of Factors Influencing Cyclic Fatigue of Nickel-Titanium Endodontic Instruments

    Directory of Open Access Journals (Sweden)

    Eva Fišerová

    2015-01-01

    Full Text Available Objective. The aim of this study was to validate a survival analysis assessing the effect of type of rotary system, canal curvature, and instrument size on cyclic resistance. Materials and Methods. Cyclic fatigue testing was carried out in stainless steel artificial canals with radii of curvature of 3 or 5 mm and the angle of curvature of 60 degrees. All the instruments were new and 25 mm in working length, and ISO colour coding indicated the instrument size (yellow for size 20; red for size 25. Wizard Navigator instruments, Mtwo instruments, ProTaper instruments, and Revo-S instruments were passively rotated at 250 rotations per minute, and the time fracture was being recorded. Subsequently, fractographic analysis of broken tips was performed by scanning electron microscope. The data were then analysed by the Kaplan-Meier estimator of the survival function, the Cox proportional hazards model, the Wald test for regression covariates, and the Wald test for significance of regression model. Conclusion. The lifespan registered for the tested instruments was Mtwo > Wizard Navigator > Revo-S > ProTaper; 5 mm radius > 3 mm radius; and yellow > red in ISO colour coding system.

  6. ANALYSIS COGNITIVE DOMAIN INSTRUMENTS OF EVALUATION IN SMA BANDUNG

    Directory of Open Access Journals (Sweden)

    sepita ferazona

    2018-01-01

    Full Text Available The level of competence achievement will be known by evaluating the students after all the basic competencies that exist in the standard of the content they are studying, which must be seen how the suitability of the evaluation instruments provided to the students with the demands of basic competencies and the process of learning in the class .. The method used in this researchis a descriptive method. Subjects were ten biology teachers from seven SMANs in Bandung as a sample, each school representing three clusters. Selection of this research sample is done by using stratified sampling technique, that is by choosing school with high category, medium and low. KD analyzed material of Class X Plantae and Class X Excression System. Plantae material learning process question and excretion system on cluster 1, the highest average at level C2 (understanding that is equal to 55,91%. While on cluster 2 the highest average also at level C2 (understanding that is equal to 50,96%. While on the cluster 3 the highest average is also at level C2 (understand that is equal to 48,91%. The cognitive domain of Plantae's exercise / material tasks in cluster 1, the highest average at the level C1 (knowledge is 57.5%. While on the cluster 2 the highest average also at level C1 (knowledge that is equal to 71,67%. While the highest average cluster is at level C2 (understanding that is equal to 51,67%. The cognitive domain of Plantae material repetition and Excretion System in cluster 1, the highest average at the level of C1 (knowledge is 56.67%. While on the cluster 2 average highest at level C1 (knowledge that is equal to 56,3%. While on the cluster 3 highest cognitive domain is at level C1 (knowledge that is equal to 52,55%.

  7. Preliminary analysis of the transient overpower accident for CRBRP. Final report

    International Nuclear Information System (INIS)

    Kastenberg, W.E.; Frank, M.V.

    1975-07-01

    A preliminary analysis of the transient overpower accident for the Clinch River Breeder Reactor Plant (CRBRP) is presented. Several uncertainties in the analysis and the estimation of ramp rates during the transition to disassembly are discussed. The major conclusions are summarized

  8. SUMS preliminary design and data analysis development. [shuttle upper atmosphere mass spectrometer experiment

    Science.gov (United States)

    Hinson, E. W.

    1981-01-01

    The preliminary analysis and data analysis system development for the shuttle upper atmosphere mass spectrometer (SUMS) experiment are discussed. The SUMS experiment is designed to provide free stream atmospheric density, pressure, temperature, and mean molecular weight for the high altitude, high Mach number region.

  9. Full-Band Quasi-Harmonic Analysis and Synthesis of Musical Instrument Sounds with Adaptive Sinusoids

    Directory of Open Access Journals (Sweden)

    Marcelo Caetano

    2016-05-01

    Full Text Available Sinusoids are widely used to represent the oscillatory modes of musical instrument sounds in both analysis and synthesis. However, musical instrument sounds feature transients and instrumental noise that are poorly modeled with quasi-stationary sinusoids, requiring spectral decomposition and further dedicated modeling. In this work, we propose a full-band representation that fits sinusoids across the entire spectrum. We use the extended adaptive Quasi-Harmonic Model (eaQHM to iteratively estimate amplitude- and frequency-modulated (AM–FM sinusoids able to capture challenging features such as sharp attacks, transients, and instrumental noise. We use the signal-to-reconstruction-error ratio (SRER as the objective measure for the analysis and synthesis of 89 musical instrument sounds from different instrumental families. We compare against quasi-stationary sinusoids and exponentially damped sinusoids. First, we show that the SRER increases with adaptation in eaQHM. Then, we show that full-band modeling with eaQHM captures partials at the higher frequency end of the spectrum that are neglected by spectral decomposition. Finally, we demonstrate that a frame size equal to three periods of the fundamental frequency results in the highest SRER with AM–FM sinusoids from eaQHM. A listening test confirmed that the musical instrument sounds resynthesized from full-band analysis with eaQHM are virtually perceptually indistinguishable from the original recordings.

  10. Low COST surgery setting for one-operational port laparoscopic hysterectomy surgery with ordinary laparoscopic instruments: preliminary results.

    Science.gov (United States)

    Limberger, Leo Francisco; Campos, Luciana Silveira; da Alves, Nilton Jacinto Rosa; Pedrini, Daniel Siqueira; de Limberger, Andiara Souza

    2013-10-02

    Hysterectomy dates back to 120BC and is the second most commonly performed gynecological surgery in the world. Cosmetic demands and the necessity of rapid return to work have contributed to the minimally invasive laparoscopic approach for hysterectomy. The majority of reports describe the use of three or four incisions to perform the surgery (two or three for manipulation and one for optics). This work describes our experience with using only two ports for 11 patients who underwent video-laparoscopic hysterectomy surgery. One port was used for the optical system, and the second was used for manipulation. Early and late surgery complications, as well as the time to return to work and daily activities, were assessed. The mean age of the patients was 41.4 years old (range 16 to 52 years) and the mean uterine weight was 133.54 g, ranging from 35 g and 291 g. The operative time ranged from 30 to 60 minutes (average 46.4 minutes) and the hospital stay ranged between 24 and 48 hrs. No intraoperative complications occurred, and no early or late postoperative complications were recorded. Patients reported minimal pain during the first 24-48 hrs in the hospital. Patients returned to their daily activities within seven days after surgery. Clinical care follow-up continued until the 40th postoperative day. The laparoscopic hysterectomy technique with a single port for manipulation is a feasible procedure when the uterine weight is not greater than 400 mg with little postoperative pain. The patients had an early return-to-work and daily activities and a better cosmetic outcome. These preliminary data led us to make the one-operative port laparoscopic hysterectomy the procedure of choice for patients with a low uterine weight.

  11. Sequential-Injection Analysis: Principles, Instrument Construction, and Demonstration by a Simple Experiment

    Science.gov (United States)

    Economou, A.; Tzanavaras, P. D.; Themelis, D. G.

    2005-01-01

    The sequential-injection analysis (SIA) is an approach to sample handling that enables the automation of manual wet-chemistry procedures in a rapid, precise and efficient manner. The experiments using SIA fits well in the course of Instrumental Chemical Analysis and especially in the section of Automatic Methods of analysis provided by chemistry…

  12. Characterisation of South African coals using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Hart, R.J.

    1985-01-01

    This report includes the establishment of the major minor and trace element compositions of South African coals with the aim of characterising the different coal seams within a basin, defining regions of similar compositions and obtaining an overall view of the geochemistry of coals in this country. The results of 40 coal samples analysed by neutron activation analysis

  13. Robust IFE Based Order Analysis of Rotating Machinery in Virtual Instrument

    International Nuclear Information System (INIS)

    Guo, Y; Chi, Y L; Huang, Y Y; Qin, S R

    2006-01-01

    Character analysis plays an important role in fault-find and diagnosis of rotating machinery. Order analysis is one of the major methods in character analysis for the analysis of non-stationary vibration signals in run-up or coast down of rotating machinery. An order analysis method, which employs instantaneous frequency estimation based on time-frequency analysis, is introduced. In contrast with traditional order analysis methods, this method avoids the use of tachometer and other special hardware; hence it makes the application of order analysis simplified. The order analysis introduced in the paper with the character that only software is depended for order tracking makes it specially satisfy the requirement of Virtual Instruments. Corresponding order analysis items, such as order spectrum, order spectrum matrix and tracking order spectrum etc., which are applied in Virtual Instruments, are also introduced. A test example is provided to demonstrate the validity of the method presented

  14. Multielement characterization of atmospheric pollutants by x-ray fluorescence analysis and instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Rancitelli, L.A.; Tanner, T.M.

    1976-01-01

    The simultaneous measurement of a wide spectrum of elements in aerosols collected on air filters and in rainwater can yield information on the origin, transport, and removal of atmospheric pollutants. In order to determine the elemental content of these aerosols, a pair of highly sensitive, precise and complementing instrumental techniques, x-ray fluorescence and neutron activation analysis, have been developed and employed. Data are presented on the results of combined x-ray fluorescence and activation analysis of aerosols collected in a number of urban areas of the USA and from the 80th median sampling network in March 1972. From a comparison of these ratios in granite and diabase with those of filters placed in urban areas, it is evident that Zn, Se, Sb, Hg, and Pb levels have been increased by as much as several orders of magnitude. Al, Co, La, Fe, Eu, Sm, Tb, Ta, Hf, and Th appear to exist at levels compatible with an earth's crust origin

  15. The Complex Trauma Questionnaire (ComplexTQ:Development and preliminary psychometric properties of an instrument for measuring early relational trauma

    Directory of Open Access Journals (Sweden)

    Carola eMaggiora Vergano

    2015-09-01

    Full Text Available Research on the etiology of adult psychopathology and its relationship with childhood trauma has focused primarily on specific forms of maltreatment. This study developed an instrument for the assessment of childhood and adolescence trauma that would aid in identifying the role of co-occurring childhood stressors and chronic adverse conditions. The Complex Trauma Questionnaire (ComplexTQ, in both clinician and self-report versions, is a measure for the assessment of multi-type maltreatment: physical, psychological, and sexual abuse; physical and emotional neglect as well as other traumatic experiences, such rejection, role reversal, witnessing domestic violence, separations, and losses. The four-point Likert scale allows to specifically indicate with which caregiver the traumatic experience has occurred. A total of 229 participants, a sample of 79 nonclinical and that of 150 high-risk and clinical participants, were assessed with the ComplexTQ clinician version applied to Adult Attachment Interview (AAI transcripts. Initial analyses indicate acceptable inter-rater reliability. A good fit to a 6-factor model regarding the experience with the mother and to a 5-factor model with the experience with the father was obtained; the internal consistency of factors derived was good. Convergent validity was provided with the AAI scales. ComplexTQ factors discriminated normative from high-risk and clinical samples. The findings suggest a promising, reliable, and valid measurement of early relational trauma that is reported; furthermore, it is easy to complete and is useful for both research and clinical practice.

  16. Predicting child maltreatment: A meta-analysis of the predictive validity of risk assessment instruments.

    Science.gov (United States)

    van der Put, Claudia E; Assink, Mark; Boekhout van Solinge, Noëlle F

    2017-11-01

    Risk assessment is crucial in preventing child maltreatment since it can identify high-risk cases in need of child protection intervention. Despite widespread use of risk assessment instruments in child welfare, it is unknown how well these instruments predict maltreatment and what instrument characteristics are associated with higher levels of predictive validity. Therefore, a multilevel meta-analysis was conducted to examine the predictive accuracy of (characteristics of) risk assessment instruments. A literature search yielded 30 independent studies (N=87,329) examining the predictive validity of 27 different risk assessment instruments. From these studies, 67 effect sizes could be extracted. Overall, a medium significant effect was found (AUC=0.681), indicating a moderate predictive accuracy. Moderator analyses revealed that onset of maltreatment can be better predicted than recurrence of maltreatment, which is a promising finding for early detection and prevention of child maltreatment. In addition, actuarial instruments were found to outperform clinical instruments. To bring risk and needs assessment in child welfare to a higher level, actuarial instruments should be further developed and strengthened by distinguishing risk assessment from needs assessment and by integrating risk assessment with case management. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. A preliminary analysis of the reactor-based plutonium disposition alternative deployment schedules

    International Nuclear Information System (INIS)

    Zurn, R.M.

    1997-09-01

    This paper discusses the preliminary analysis of the implementation schedules of the reactor-based plutonium disposition alternatives. These schedule analyses are a part of a larger process to examine the nine decision criteria used to determine the most appropriate method of disposing of U.S. surplus weapons plutonium. The preliminary analysis indicates that the mission durations for the reactor-based alternatives range from eleven years to eighteen years and the initial mission fuel assemblies containing surplus weapons-usable plutonium could be loaded into the reactors between nine and fourteen years after the Record of Decision

  18. Purification, crystallization and preliminary X-ray structure analysis of the laccase from Ganoderma lucidum

    International Nuclear Information System (INIS)

    Lyashenko, Andrey V.; Belova, Oksana; Gabdulkhakov, Azat G.; Lashkov, Alexander A.; Lisov, Alexandr V.; Leontievsky, Alexey A.; Mikhailov, Al’bert M.

    2011-01-01

    The purification, crystallization and preliminary X-ray structure analysis of the laccase from G. lucidum are reported. The ligninolytic enzymes of the basidiomycetes play a key role in the global carbon cycle. A characteristic property of these enzymes is their broad substrate specificity, which has led to their use in various biotechnologies, thus stimulating research into the three-dimensional structures of ligninolytic enzymes. This paper presents the purification, crystallization and preliminary X-ray analysis of the laccase from the ligninolytic basidiomycete Ganoderma lucidum

  19. NRC staff preliminary analysis of public comments on advance notice of proposed rulemaking on emergency planning

    International Nuclear Information System (INIS)

    Peabody, C.A.; Hickey, J.W.N.

    1980-01-01

    The Nuclear Regulatory Commission (NRC) published an advance notice of proposed rulemaking on emergency planning on July 17, 1979 (44 FR 41483). In October and November 1979, the NRC staff submitted several papers to the Commission related to the emergency planning rulemaking. One of these papers was a preliminary analysis of public comments received on the advance notice (SECY-79-591B, November 13, 1979). This document consists of the preliminary analysis as it was submitted to the Commission, with minor editorial changes

  20. Instrumental neutron activation analysis of pottery for provenience study

    International Nuclear Information System (INIS)

    Kuleff, I.; Djingova, R.; Penev, I.

    1986-01-01

    A scheme for INAA of pottery is proposed. The combination of 3 irradiations - epithermal and pile (short and long time) - and 6 measurements (2 times after each irradiation) enables the determination of Al, As, Au, Ba, Br, Ce, Co, Cr, Cs, Dy, Eu, Fe, Hf, K, La, Lu, Mg, Mn, Na, Nd, Rb, Sb, Sc, Si, Sm, Ta, Tb, Th, Ti, U, V and Yb. The accuracy and precision of the method is evaluated by analysis of standard reference materials (USGS-BCR-1, USGS-W-1, ZGI-TB). The applicability of the method is demonstrated by analysis of 15 sgraffito ceramics from XV-XVIII cc. from Tsarevets, Veliko Tirnovo (Bulgaria). The results from the clustering of the analytical data are presented and discussed. (author)

  1. Time series analysis of nuclear instrumentation in EBR-II

    International Nuclear Information System (INIS)

    Imel, G.R.

    1996-01-01

    Results of a time series analysis of the scaler count data from the 3 wide range nuclear detectors in the Experimental Breeder Reactor-II are presented. One of the channels was replaced, and it was desired to determine if there was any statistically significant change (ie, improvement) in the channel's response after the replacement. Data were collected from all 3 channels for 16-day periods before and after detector replacement. Time series analysis and statistical tests showed that there was no significant change after the detector replacement. Also, there were no statistically significant differences among the 3 channels, either before or after the replacement. Finally, it was determined that errors in the reactivity change inferred from subcritical count monitoring during fuel handling would be on the other of 20-30 cents for single count intervals

  2. Thick Concrete Specimen Construction, Testing, and Preliminary Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hoegh, Kyle [Univ. of Minnesota, Minneapolis, MN (United States); Khazanovich, Lev [Univ. of Minnesota, Minneapolis, MN (United States)

    2015-03-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations. A preliminary report detailed some of the challenges associated with thick reinforced concrete sections and prioritized conceptual designs of specimens that could be fabricated to represent NPP concrete structures for using in NDE evaluation comparisons. This led to the construction of the concrete specimen presented in this report, which has sufficient reinforcement density and cross-sectional size to represent an NPP containment wall. Details on how a suitably thick concrete specimen was constructed are presented, including the construction materials, final nominal design schematic, as well as formwork and rigging required to safely meet the desired dimensions of the concrete structure. The report also details the type and methods of forming the concrete specimen as well as information on how the rebar and simulated defects were embedded. Details on how the resulting specimen was transported, safely anchored, and marked to allow access for systematic comparative NDE testing of defects in a representative NPP containment wall concrete specimen are also given. Data collection using the MIRA Ultrasonic NDE equipment and

  3. Comparison of neutron activation analysis with other instrumental methods for elemental analysis of airborne particulate matter

    International Nuclear Information System (INIS)

    Regge, P. de; Lievens, F.; Delespaul, I.; Monsecour, M.

    1976-01-01

    A comparison of instrumental methods, including neutron activation analysis, X-ray fluorescence spectrometry, atomic absorption spectrometry and emission spectrometry, for the analysis of heavy metals in airborne particulate matter is described. The merits and drawbacks of each method for the routine analysis of a large number of samples are discussed. The sample preparation technique, calibration and statistical data relevant to each method are given. Concordant results are obtained by the different methods for Co, Cu, Ni, Pb and Zn. Less good agreement is obtained for Fe, Mn and V. The results are not in agreement for the elements Cd and Cr. Using data obtained on the dust sample distributed by Euratom-ISPRA within the framework of an interlaboratory comparison, the accuracy of each method for the various elements is estimated. Neutron activation analysis was found to be the most sensitive and accurate of the non-destructive analysis methods. Only atomic absorption spectrometry has a comparable sensitivity, but requires considerable preparation work. X-ray fluorescence spectrometry is less sensitive and shows biases for Cr and V. Automatic emission spectrometry with simultaneous measurement of the beam intensities by photomultipliers is the fastest and most economical technique, though at the expense of some precision and sensitivity. (author)

  4. Instrumental determination of iodine in milk by neutron activation analysis

    International Nuclear Information System (INIS)

    Isaac Olive, K.; Chatt, A.

    2006-01-01

    Iodine is an essential trace element. It is related to thyroid functions and its deficiency or excess can be harmful. Deficiency of iodine leads to brain damage including cretinism, excess of iodine blocks the thyroid gland ultimately producing iodine deficiency as well. World Health Organization has set a daily iodine intake dose of 150 μg d -1 . Currently there are 740 million people in the world at risk of iodine deficiency disorders; therefore the monitoring of iodine intake is necessary. Although the iodized salt policy has been adopted in many countries, milk is also one of the major natural sources of iodine and it is also the principal food in children. Therefore, the determination of iodine in milk is needed. This work deals with the determination of iodine in milk by neutron activation analysis. Different methods of irradiation-counting are compared in terms of sensitivity and detection limits. The quantification of iodine was calculated using also two methods, the classic relative one and the standardization of k 0 parameter. A brief analysis of the uncertainty sources in the analytical method is also discussed.(Full text)

  5. Analysis of Bonds as an Instrument for Financing Mining Investments

    Science.gov (United States)

    Ranosz, Robert

    2017-06-01

    The purpose of this article is to examine the structure of financing for mining enterprises in the years 2007-2013, with particular emphasis on bonds. The document pays special attention to Polish mining enterprises. The financing structure analysis was based on data collected from financial statements (cash flows) of the largest mining companies in Poland, and their comparison with the results of global mining enterprises pursuant to reports prepared by international advisory firms. The article takes into account capital sources such as: corporate bonds, bank loans and issue of shares. As indicated by the performed analysis, mining enterprises both around the world and in Poland are increasingly eager to take advantage of obtaining business financing from issue of corporate bonds. It should also be recognized that in the analyzed period, both global and Polish mining enterprises deviate from forms of financing such as issue of shares. This may be caused by the fact that the bonds market in Poland is becoming increasingly popular, mainly due to interest rate on bonds being lower in comparison with bank loans. Another reason may be that banks and potential buyers of shares are less eager to finance this type of investment due to a relatively substantial risk acceptable to bondholders.

  6. Preliminary Coupling of MATRA Code for Multi-physics Analysis

    International Nuclear Information System (INIS)

    Kim, Seongjin; Choi, Jinyoung; Yang, Yongsik; Kwon, Hyouk; Hwang, Daehyun

    2014-01-01

    The boundary conditions such as the inlet temperature, mass flux, averaged heat flux, power distributions of the rods, and core geometry is given by constant values or functions of time. These conditions are separately calculated and provided by other codes, such as a neutronics or a system codes, into the MATRA code. In addition, the coupling of several codes in the different physics field is focused and embodied. In this study, multiphysics coupling methods were developed for a subchannel code (MATRA) with neutronics codes (MASTER, DeCART) and a fuel performance code (FRAPCON-3). Preliminary evaluation results for representative sample cases are presented. The MASTER and DeCART codes provide the power distribution of the rods in the core to the MATRA code. In case of the FRAPCON-3 code, the variation of the rod diameter induced by the thermal expansion is yielded and provided. The MATRA code transfers the thermal-hydraulic conditions that each code needs. Moreover, the coupling method with each code is described

  7. Preliminary Analysis of Species Partitioning in the DWPF Melter

    Energy Technology Data Exchange (ETDEWEB)

    Choi, A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Kesterson, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Johnson, F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-07-15

    The work described in this report is preliminary in nature since its goal was to demonstrate the feasibility of estimating the off-gas entrainment rates from the Defense Waste Processing Facility (DWPF) melter based on a simple mass balance using measured feed and glass pour stream compositions and timeaveraged melter operating data over the duration of one canister-filling cycle. The only case considered in this study involved the SB6 pour stream sample taken while Canister #3472 was being filled over a 20-hour period on 12/20/2010, approximately three months after the bubblers were installed. The analytical results for that pour stream sample provided the necessary glass composition data for the mass balance calculations. To estimate the “matching” feed composition, which is not necessarily the same as that of the Melter Feed Tank (MFT) batch being fed at the time of pour stream sampling, a mixing model was developed involving three preceding MFT batches as well as the one being fed at that time based on the assumption of perfect mixing in the glass pool but with an induction period to account for the process delays involved in the calcination/fusion step in the cold cap and the melter turnover.

  8. Analysis and research of PWR instrument commissioning based on Simulink

    International Nuclear Information System (INIS)

    Luan Zhenhua; Liu Daoguang; Qiu Shaoshuai; Yang Zongwei; Feng Guangyu

    2013-01-01

    Based on Simulink platform, a mathematical model of the lead lag link, differential unit, arithmetic logic module is built. Considering the specific problems encountered in the debug field work, this model is applied in the analysis of key modules and controller and in the resolving of eddy current problems. The test process dynamic control characteristic is simulated, to analyze the trend of the actual response, and conduct the simulation study and propose the concrete solutions. The actual debugging process proved that the use of simulation technology to find the problem, optimize the control data, and adjust the control strategy is very important for the early detection of problems and to speed the test process, shorten the debug duration and increase the debug quality. (authors)

  9. Delayed phenomena analysis from French PWR containment instrumentation system

    International Nuclear Information System (INIS)

    Costaz, J.L.

    1987-01-01

    The analysis of the large amount of measurements which has been now gathered by EDF on its twenty two PWR 900 MW shows that the behaviour of concrete under creep and shrinkage effects is in good agreement with the values given as correct estimates by french regulations and taken into account for the design of nuclear prestressed structures. None of the containment buildings studied here showed significant differences with the regulations theoretical values and consequently all the measurements remain in the field of the allowable strain variations used for design. On the other hand, if the instant loading elastic modulus is clearly determined for each containment, and its effect on theoretical creep taken into account, it was not possible up till now to extract from measurements some particular effects such as type of concrete and agregates or climatic effects. (orig.)

  10. TEABAGS: computer programs for instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lindstrom, D J [Washington Univ., St. Louis, MO (USA); Korotev, R L [Washington Univ., St. Louis, MO (USA). McDonnell Center for the Space Sciences

    1982-01-01

    Described is a series of INAA data reduction programs collectively known as TEABAGS (Trace Element Analysis By Automated Gamma-ray Spectrometry). The programs are written in FORTRAN and run on a Nuclear Data ND-6620 computer system, but should be adaptable to any medium-sized minicomputer. They are designed to monitor the status of all spectra obtained from samples and comparison standards irradiated together and to do all pending calculations without operator intervention. Major emphasis is placed on finding all peaks in the spectrum, properly identifying all nuclides present and all contributors to each peak, determining accurate estimates of the background continua under peaks, and producing realistic uncertainties on peak areas and final abundances.

  11. Diesel engine coolant analysis, new application for established instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, D P; Lukas, M; Lynch, B K [Spectro Incorporated, Littleton, MA (United States)

    1998-12-31

    Rotating disk electrode (RDE) arc emission spectrometers are user` many commercial, industrial and military laboratories throughout the world to analyze millions of oil and fuel samples each year. In fact, RDE spectrometers have been used exclusively for oil and fuel analysis for so long that it has nearly been forgotten by most practitioners that when RDE spectrometers were first introduced more than 40 years ago, they were routinely used for aqueous samples as well. This presentation reviews early methods of aqueous sample analysis using RDE technology. This presentation also describes recent work to calibrate an RDE spectrometer for both water samples and for engine coolant samples which are a mixture of approximately 50 % water and 50 % ethylene or propylene glycol. Limits of detection determined for aqueous standards are comparable to limits of detection for oil standards. Repeatability of aqueous samples is comparable to the repeatability achieved for oil samples. A comparison of results for coolant samples measured by both inductively coupled plasma (ICP) and rotating disk electrode (RDE) spectrometers is presented. Not surprisingly, RDE results are significantly higher for samples containing particles larger than a few micrometers. Although limits of detection for aqueous samples are not as low as can be achieved using the more modern ICP spectrometric method or the more cumbersome atomic absorption (AA) method, this presentation suggests that RDE spectrometers may be appropriate for certain types of aqueous samples in situations where the more sensitive ICP or AA spectrometers and the laboratory environment and skilled personnel needed for them to operate are not conveniently available. (orig.) 4 refs.

  12. Diesel engine coolant analysis, new application for established instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, D.P.; Lukas, M.; Lynch, B.K. [Spectro Incorporated, Littleton, MA (United States)

    1997-12-31

    Rotating disk electrode (RDE) arc emission spectrometers are user` many commercial, industrial and military laboratories throughout the world to analyze millions of oil and fuel samples each year. In fact, RDE spectrometers have been used exclusively for oil and fuel analysis for so long that it has nearly been forgotten by most practitioners that when RDE spectrometers were first introduced more than 40 years ago, they were routinely used for aqueous samples as well. This presentation reviews early methods of aqueous sample analysis using RDE technology. This presentation also describes recent work to calibrate an RDE spectrometer for both water samples and for engine coolant samples which are a mixture of approximately 50 % water and 50 % ethylene or propylene glycol. Limits of detection determined for aqueous standards are comparable to limits of detection for oil standards. Repeatability of aqueous samples is comparable to the repeatability achieved for oil samples. A comparison of results for coolant samples measured by both inductively coupled plasma (ICP) and rotating disk electrode (RDE) spectrometers is presented. Not surprisingly, RDE results are significantly higher for samples containing particles larger than a few micrometers. Although limits of detection for aqueous samples are not as low as can be achieved using the more modern ICP spectrometric method or the more cumbersome atomic absorption (AA) method, this presentation suggests that RDE spectrometers may be appropriate for certain types of aqueous samples in situations where the more sensitive ICP or AA spectrometers and the laboratory environment and skilled personnel needed for them to operate are not conveniently available. (orig.) 4 refs.

  13. Defect propagation in NiTi rotary instruments: a noncontact optical profilometry analysis.

    Science.gov (United States)

    Barbosa, I; Ferreira, F; Scelza, P; Neff, J; Russano, D; Montagnana, M; Zaccaro Scelza, M

    2018-04-10

    To evaluate the presence and propagation of defects and their effects on surfaces of nickel-titanium (NiTi) instruments using noncontact, three-dimensional optical profilometry, and to assess the accuracy of this method of investigation. The flute surface areas of instruments from two commercial instrumentation systems, namely Reciproc R25 (n = 5) and WaveOne Primary (n = 5), were assessed and compared before and after performing two instrumentation cycles in simulated root canals in clear resin blocks. All the analyses were conducted on areas measuring 211 × 211 μm, located 3 mm from the tips of the instruments. A quantitative analysis was conducted before and after the first and second instrumentation cycles, using the Sa (average roughness over the measurement field), Sq (root mean square roughness) and Sz (average height over the measurement field) amplitude parameters. All the data were submitted to statistical analysis at a 5% level of significance. There was a significant increase (P = 0.007) in wear in both groups, especially between baseline and the second instrumentation cycle, with significantly higher wear values being observed on WaveOne instruments (Sz median values = 33.68 and 2.89 μm, respectively, for WO and RP groups). A significant increase in surface roughness (P = 0.016 and P = 0.008, respectively, for Sa and Sq) was observed in both groups from the first to the second instrumentation cycle, mostly in WaveOne specimens. Qualitative analysis revealed a greater number of defects on the flute topography of all the instruments after use. More defects were identified in WaveOne Primary instruments compared to Reciproc R25, irrespective of the evaluation stage. The investigation method provided an accurate, repeatable and reproducible assessment of NiTi instruments at different time-points. © 2018 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  14. A review of modern instrumental methods of elemental analysis of petroleum related material. Part 2

    International Nuclear Information System (INIS)

    Nadkarni, R.A.

    1991-01-01

    In this paper a review is presented of the state of the art in elemental analysis of petroleum-related materials (crude oil, gasoline, additives, and lubricants) using modern instrumental analysis techniques. The major instrumental techniques used for elemental analysis of petroleum products include atomic absorption spectrometry (both with flame and with graphite furnace atomizer), inductively coupled plasma atomic emission spectrometry, ion chromatography, microelemental methods, neutron activation, spark source mass spectrometry, and x-ray fluorescence. Each of these techniques is compared for its advantages, disadvantages, and typical applications in the petroleum field

  15. Fukushima Daiichi unit 1 uncertainty analysis--Preliminary selection of uncertain parameters and analysis methodology

    Energy Technology Data Exchange (ETDEWEB)

    Cardoni, Jeffrey N.; Kalinich, Donald A.

    2014-02-01

    Sandia National Laboratories (SNL) plans to conduct uncertainty analyses (UA) on the Fukushima Daiichi unit (1F1) plant with the MELCOR code. The model to be used was developed for a previous accident reconstruction investigation jointly sponsored by the US Department of Energy (DOE) and Nuclear Regulatory Commission (NRC). However, that study only examined a handful of various model inputs and boundary conditions, and the predictions yielded only fair agreement with plant data and current release estimates. The goal of this uncertainty study is to perform a focused evaluation of uncertainty in core melt progression behavior and its effect on key figures-of-merit (e.g., hydrogen production, vessel lower head failure, etc.). In preparation for the SNL Fukushima UA work, a scoping study has been completed to identify important core melt progression parameters for the uncertainty analysis. The study also lays out a preliminary UA methodology.

  16. Preliminary Psychometric Analysis of the Modified Perceived Value of Certification Tool for the Nurse Educator.

    Science.gov (United States)

    Barbe, Tammy

    2015-01-01

    The purpose of this study was to examine psychometric properties of the Perceived Value of Certification Tool© with a focus on nurse educator certification (PVCT-NE) in a sample of nurse educators. Greater understanding of faculty perceptions of certification is necessary to facilitate a strong cadre of nursing faculty; however, research around nurse educator certification is limited by a lack of reliable and valid instruments to measure such perceptions. Twenty-four nursing faculty from one university participated in the psychometric study, which involved completion of the PVCT-NE in a web-based survey format. Internal consistency reliability was excellent. Cronbach's alpha for the total PVCT-NE was .94 (.93 for the intrinsic subscale and .86 for the extrinsic subscale). A content validity index of .95 was obtained. There is preliminary evidence that the PVCT-NE is a reliable and valid instrument to measure perceived value of certification in nurse educators.

  17. The Cambridge Otology Quality of Life Questionnaire: an otology-specific patient-recorded outcome measure. A paper describing the instrument design and a report of preliminary reliability and validity.

    Science.gov (United States)

    Martin, T P C; Moualed, D; Paul, A; Ronan, N; Tysome, J R; Donnelly, N P; Cook, R; Axon, P R

    2015-04-01

    The Cambridge Otology Quality of Life Questionnaire (COQOL) is a patient-recorded outcome measurement (PROM) designed to quantify the quality of life of patients attending otology clinics. Item-reduction model. A systematically designed long-form version (74 items) was tested with patient focus groups before being presented to adult otology patients (n. 137). Preliminary item analysis tested reliability, reducing the COQOL to 24 questions. This was then presented in conjunction with the SF-36 (V1) questionnaire to a total of 203 patients. Subsequently, these were re-presented at T + 3 months, and patients recorded whether they felt their condition had improved, deteriorated or remained the same. Non-responders were contacted by post. A correlation between COQOL scores and patient perception of change was examined to analyse content validity. Teaching hospital and university psychology department. Adult patients attending otology clinics with a wide range of otological conditions. Item reliability measured by item–total correlation, internal consistency and test– retest reliability. Validity measured by correlation between COQOL scores and patient-reported symptom change. Reliability: the COQOL showed excellent internal consistency at both initial presentation (a = 0.90) and 3 months later (a = 0.93). Validity: One-way analysis of variance showed a significant difference between groups reporting change and those reporting no change in quality of life (F(2, 80) = 5.866, P < 0.01). The COQOL is the first otology-specific PROM. Initial studies demonstrate excellent reliability and encouraging preliminary criterion validity: further studies will allow a deeper validation of the instrument.

  18. Network Analysis as a Communication Audit Instrument: Uncovering Communicative Strengths and Weaknesses Within Organizations

    NARCIS (Netherlands)

    Koning, K.H.; de Jong, Menno D.T.

    2015-01-01

    Network analysis is one of the instruments in the communication audit toolbox to diagnose communication problems within organizations. To explore its contribution to a communication audit, the authors conducted a network analysis within three secondary schools, comparing its results with those of

  19. Validation of an Instrument and Testing Protocol for Measuring the Combinatorial Analysis Schema.

    Science.gov (United States)

    Staver, John R.; Harty, Harold

    1979-01-01

    Designs a testing situation to examine the presence of combinatorial analysis, to establish construct validity in the use of an instrument, Combinatorial Analysis Behavior Observation Scheme (CABOS), and to investigate the presence of the schema in young adolescents. (Author/GA)

  20. ISO Guest Observer Data Analysis and LWS Instrument Team Activities

    Science.gov (United States)

    Smith, Howard

    2001-01-01

    The following is an interim annual report. Dr. Smith is currently on an extended TDY to the Istituto di Fisica dello Spazio Interplanetario (IFSI) at the Consilio Nazionale delle Richerche (CNR) in Rome, Italy, where he has been working on a related NASA grant in support of analysis of Infrared Space Observatory (ISO) data on star formation in Ultra Luminous Infrared Galaxies and our galaxy. Work emphasizes development of metal mesh grids for use in spacecraft, and the design and fabrication of test elements by the Naval Research Laboratory, Washington D.C. Work has progressed well, but slowly, on that program due to the departure of a key engineer. NASA has been advised of the delay, and granted a no-cost extension, whereby SAO has authorized a delay in the final report from NRL. Nevertheless NRL has continued to make progress. Two papers have been submitted to refereed journals related to this program, and a new design for mesh operating in the 20-40 micron region has been developed. Meetings continue through the summer on these items. A new technical scientist has been made a job offer and hopefully will be on board NRL shortly, although most of the present grant work is already completed. A more complete report, with copies of the submitted papers, designs, and other measures of progress, will be submitted to NASA in September when Dr. Smith returns from his current TDY.

  1. Current studies of biological materials using instrumental and radiochemical neutron activation analysis

    International Nuclear Information System (INIS)

    Fardy, J.J.; McOrist, G.D.; Farrar, Y.J.

    1985-01-01

    Instrumental neutron activation analysis still remains the preferred option when analysing the trace element distribution in a wide rage of materials by neutron activation analysis. However, when lower limits of detection are required or major interferences reduce the effectiveness of this technique, radiochemical neutron activation analysis is applied. This paper examines the current use of both methods and the development of rapid radiochemical techniques for analysis of the biological materials, hair, cow's milk, human's milk, milk powder, blood and blood serum

  2. LOFT reactor vessel 290/sup 0/ downcomer stalk instrument penetration flange stress analysis

    Energy Technology Data Exchange (ETDEWEB)

    Finicle, D.P.

    1978-06-06

    The LOFT Reactor Vessel 290/sup 0/ Downcomer Stalk Instrument Penetration Flange Stress Analysis has been completed using normal operational and blowdown loading. A linear elastic analysis was completed using simplified hand analysis techniques. The analysis was in accordance with the 1977 ASME Boiler and Pressure Vessel Code, Section III, for a Class 1 component. Loading included internal pressure, bolt preload, and thermal gradients due to normal operating and blowdown.

  3. Preliminary study of elemental analysis of hydroxyapatite used neutron activation analysis method

    International Nuclear Information System (INIS)

    Yustinus Purwamargapratala; Rina Mulyaningsih

    2010-01-01

    Preliminary study has been carried out elemental analysis of hydroxyapatite synthesized using the method of neutron activation analysis. Hydroxyapatite is the main component constituent of bones and teeth which can be synthesized from limestone and phosphoric acid. Hydroxyapatite can be used as a bone substitute material and human and animal teeth. Tests on the metal content is necessary to prevent the risk of damage to bones and teeth due to contamination. Results of analysis using neutron activation analysis method with samples irradiated at the neutron flux 10"3 n.det"-"1cm"-"2 for one minute, the impurities of Al (48.60±6.47 mg/kg), CI (38.00±7.47 mg/kg), Mn (1.05±0.19 mg/kg), and Mg (2095.30±203.66 mg/kg), were detected, whereas with irradiation time for 10 minutes and 40 minutes with a time decay of three days there were K (103.89 ± 26.82 mg/kg), Br (1617.06 ± 193.66 mg/kg), and Na (125.10±9.57 mg/kg). These results indicate that there is impurity Al, CI, Mn, Mg, Br, K and Na, although in very small amounts and do not cause damage to bones and teeth. (author)

  4. Chemical Analysis of the Moon at the Surveyor VI Landing Site: Preliminary Results.

    Science.gov (United States)

    Turkevich, A L; Patterson, J H; Franzgrote, E J

    1968-06-07

    The alpha-scattering experiment aboard soft-landing Surveyor VI has provided a chemical analysis of the surface of the moon in Sinus Medii. The preliminary results indicate that, within experimental errors, the composition is the same as that found by Surveyor V in Mare Tranquillitatis. This finding suggests that large portions of the lunar maria resemble basalt in composition.

  5. Chemical Analysis of the Moon at the Surveyor VII Landing Site: Preliminary Results.

    Science.gov (United States)

    Turkevich, A L; Franzgrote, E J; Patterson, J H

    1968-10-04

    The alpha-scattering experiment aboard Surveyor VII has provided a chemical analysis of the moon in the area of the crater Tycho. The preliminary results indicate a chemical composition similar to that already found at two mare sites, but with a lower concentration of elements of the iron group (titanium through copper).

  6. Current Mooring Design in Partner WECs and Candidates for Preliminary Analysis

    DEFF Research Database (Denmark)

    Thomsen, Jonas Bjerg; Ferri, Francesco; Kofoed, Jens Peter

    This report is the combined report of Commercial Milestone "CM1: Design and Cost of Current Mooring Solutions of Partner WECs" and Milestone "M3: Mooring Solutions for Preliminary Analysis" of the EUDP project "Mooring Solutions for Large Wave Energy Converters". The report covers a description o...

  7. ANSI/ASHRAE/IES Standard 90.1-2013 Preliminary Determination: Quantitative Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Halverson, Mark A.; Rosenberg, Michael I.; Wang, Weimin; Zhang, Jian; Mendon, Vrushali V.; Athalye, Rahul A.; Xie, YuLong; Hart, Reid; Goel, Supriya

    2014-03-01

    This report provides a preliminary quantitative analysis to assess whether buildings constructed according to the requirements of ANSI/ASHRAE/IES Standard 90.1-2013 would result in energy savings compared with buildings constructed to ANSI/ASHRAE/IES Standard 90.1-2010.

  8. Preliminary fire hazard analysis for the PUTDR and TRU trenches in the Solid Waste Burial Ground

    International Nuclear Information System (INIS)

    Gaschott, L.J.

    1995-01-01

    This document represents the Preliminary Fire Hazards Analysis for the Pilot Unvented TRU Drum Retrieval effort and for the Transuranic drum trenches in the low level burial grounds. The FHA was developed in accordance with DOE Order 5480.7A to address major hazards inherent in the facility

  9. A Preliminary Analysis of the Outcomes of Students Assisted by VET FEE-HELP: Summary

    Science.gov (United States)

    National Centre for Vocational Education Research (NCVER), 2015

    2015-01-01

    This summary highlights the key findings from the report "A preliminary analysis of the outcomes of students assisted by VET FEE-HELP". VET FEE-HELP is an income-contingent loan scheme that assists eligible students undertaking certain vocational education training (VET) courses with an approved provider by paying for all or part of…

  10. Expression, purification, crystallization and preliminary X-ray analysis of Aeromonas hydrophilia metallo-β-lactamase

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Nandini, E-mail: nandini-sharma@merck.com; Toney, Jeffrey H.; Fitzgerald, Paula M. D.

    2005-02-01

    Crystallization and preliminary X-ray analysis of the CphA metallo-β-lactamase from A. hydrophilia are described. The crystals belonged to space group P2{sub 1}2{sub 1}2, with unit-cell parameters a = 40.75, b = 42.05, c = 128.88 Å, and diffract to 1.8 Å.

  11. Preliminary Study of the Onset of Nucleate Boiling (ONB) for the Thermal-hydraulic Design of HANARO Irradiation non-instrumented Capsule during the Natural Convection

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Kyungho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The HANARO reactor is an open-tank-in-pool type for easy access, and the capsules are being utilized for the irradiation test of materials and nuclear fuel in HANARO. The concept of the capsule is the direct contact with the coolant to cool the temperature of specimen down. To successfully accomplish the irradiation test, it is essential that the capsule should be designed considering the thermal margin such as the margin to Onset of Nucleate Boiling (ONB), the margin to Departure from Nucleate Boiling (DNB). In this paper, the preliminary study was performed by focusing on the ONB and the capsule design will be performed using the heat flux and temperature at ONB condition calculated in this paper. In this paper, the temperature and heat flux under ONB condition are simply calculated for the thermal design of fuel capsule for irradiation test. These values will be considered to design the non-instrumented capsule for natural circulation. To confirm the calculated value, detailed calculation will be performed using the one dimensional and multi-dimensional codes.

  12. Preliminary safety analysis of unscrammed events for KLFR

    International Nuclear Information System (INIS)

    Kim, S.J.; Ha, G.S.

    2005-01-01

    The report presents the design features of KLFR; Safety Analysis Code; steady-state calculation results and analysis results of unscrammed events. The calculations of the steady-state and unscrammed events have been performed for the conceptual design of KLFR using SSC-K code. UTOP event results in no fuel damage and no centre-line melting. The inherent safety features are demonstrated through the analysis of ULOHS event. Although the analysis of ULOF has much uncertainties in the pump design, the analysis results show the inherent safety characteristics. 6% flow of rated flow of natural circulation is formed in the case of ULOF. In the metallic fuel rod, the cladding temperature is somewhat high due to the low heat transfer coefficient of lead. ULOHS event should be considered in design of RVACS for long-term cooling

  13. The Preliminary GAMMA Code Thermal hydraulic Analysis for the Steady State of HTR-10 Initial Core

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Ji Su; Lim, Hong Sik; Lee, Won Jae

    2006-07-15

    This report describes the preliminary thermalhydraulic analysis of HTR-10 steady state full power initial core to provide a benchmark calculation of VHTGR(Very High-Temperature Gas-Cooled Reactors) safety analysis code of GAMMA(GAs Multicomponent Mixture Analysis). The input data of GAMMA code are produced for the models of fluid block, wall block, radiation heat transfer and each component material properties in HTR-10 reactor. The temperature and flow distributions of HTR-10 steady state 10 MW{sub th} full power initial core are calculated by GAMMA code with boundary conditions of total reactor inlet flow rate of 4.32 kg/s, inlet temperature of 250 .deg. C, inlet pressure of 3 MPa, outlet pressure of 2.992 MPa and the fixed temperature at RCCS water cooling tube of 50 .deg C. The calculation results are compared with the measured solid material temperatures at 22 fixed instrumentation positions in HTR-10. The wall temperature distribution in pebble bed core shows that the minimum temperature of 358 .deg. C is located at upper core, a higher temperature zone than 829 .deg. C is located at the inner region of 0.45 m radius at the bottom of core centre, and the maximum wall temperature is 897 .deg. C. The wall temperatures linearly decreases at radially and axially farther side from the bottom of core centre. The maximum temperature of RPV is 230 .deg. C, and the maximum values of fuel average temperature and TRISO centreline temperature are 907 .deg. C and 929 .deg. C, respectively and they are much lower than the fuel temperature limitation of 1230 .deg. C. The comparsion between the GAMMA code predictions and the measured temperature data shows that the calculation results are very close to the measured values in top and side reflector region, but a great difference is appeared in bottom reflector region. Some measured data are abnormally high in bottom reflector region, and so the confirmation of data is necessary in future. Fifteen of twenty two data have a

  14. The determination of some impurities in zirconium metal by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Eddy, B.T.; Pearton, D.C.G.; Watterson, J.J.

    1976-01-01

    This report describes the work done on the development of an instrumental neutron-activation method for the analysis of impurities in reactor-grade zirconium. Nine samples were analysed, and the results were compared with those obtained by other techniques. No statistically significant differences were observed for ten of the twelve elements that could possibly be determined by instrumental neutron-activation analysis. Cadmium cannot be determined at the 0,5 p.p.m. level, and there is doubt about the comparative values recorded for aluminium. The precision of the measurement by direct instrumental neutron-activation analysis ranges from 1,4 per cent for tungsten to 17 per cent for chromium [af

  15. The Brazilian Research Consortium on Obsessive-Compulsive Spectrum Disorders: recruitment, assessment instruments, methods for the development of multicenter collaborative studies and preliminary results.

    Science.gov (United States)

    Miguel, Euripedes Constantino; Ferrão, Ygor Arzeno; Rosário, Maria Conceição do; Mathis, Maria Alice de; Torres, Albina Rodrigues; Fontenelle, Leonardo Franklin; Hounie, Ana Gabriela; Shavitt, Roseli Gedanke; Cordioli, Aristides Volpato; Gonzalez, Christina Hojaij; Petribú, Kátia; Diniz, Juliana Belo; Malavazzi, Dante Marino; Torresan, Ricardo C; Raffin, Andréa Litvin; Meyer, Elisabeth; Braga, Daniela T; Borcato, Sonia; Valério, Carolina; Gropo, Luciana N; Prado, Helena da Silva; Perin, Eduardo Alliende; Santos, Sandro Iêgo; Copque, Helen; Borges, Manuela Corrêa; Lopes, Angélica Prazeres; Silva, Elenita D da

    2008-09-01

    To describe the recruitment of patients, assessment instruments, implementation, methods and preliminary results of The Brazilian Research Consortium on Obsessive-Compulsive Spectrum Disorders, which includes seven university sites. This cross-sectional study included a comprehensive clinical assessment including semi-structured interviews (sociodemographic data, medical and psychiatric history, disease course and comorbid psychiatric diagnoses), and instruments to assess obsessive-compulsive (Yale-Brown Obsessive-Compulsive Scale and Dimensional Yale-Brown Obsessive-Compulsive Scale), depressive (Beck Depression Inventory) and anxious (Beck Anxiety Inventory) symptoms, sensory phenomena (Universidade de São Paulo Sensory Phenomena Scale), insight (Brown Assessment Beliefs Scale), tics (Yale Global Tics Severity Scale) and quality of life (Medical Outcome Quality of Life Scale Short-form-36 and Social Assessment Scale). The raters' training consisted of watching at least five videotaped interviews and interviewing five patients with an expert researcher before interviewing patients alone. The reliability between all leaders for the most important instruments (Structured Clinical Interview for DSM-IV, Dimensional Yale-Brown Obsessive-Compulsive Scale, Universidade de São Paulo Sensory Phenomena Scale) was measured after six complete interviews. Inter-rater reliability was 96%. By March 2008, 630 obsessive-compulsive disorder patients had been systematically evaluated. Mean age (+/-SE) was 34.7 (+/-0.51), 56.3% were female, and 84.6% Caucasian. The most prevalent obsessive compulsive symptom dimensions were symmetry and contamination. The most common comorbidities were major depression, generalized anxiety and social anxiety disorder. The most common DSM-IV impulsive control disorder was skin picking. The sample was composed mainly by Caucasian individuals, unmarried, with some kind of occupational activity, mean age of 35 years, onset of obsessive

  16. First fungal genome sequence from Africa: A preliminary analysis

    Directory of Open Access Journals (Sweden)

    Rene Sutherland

    2012-01-01

    Full Text Available Some of the most significant breakthroughs in the biological sciences this century will emerge from the development of next generation sequencing technologies. The ease of availability of DNA sequence made possible through these new technologies has given researchers opportunities to study organisms in a manner that was not possible with Sanger sequencing. Scientists will, therefore, need to embrace genomics, as well as develop and nurture the human capacity to sequence genomes and utilise the ’tsunami‘ of data that emerge from genome sequencing. In response to these challenges, we sequenced the genome of Fusarium circinatum, a fungal pathogen of pine that causes pitch canker, a disease of great concern to the South African forestry industry. The sequencing work was conducted in South Africa, making F. circinatum the first eukaryotic organism for which the complete genome has been sequenced locally. Here we report on the process that was followed to sequence, assemble and perform a preliminary characterisation of the genome. Furthermore, details of the computer annotation and manual curation of this genome are presented. The F. circinatum genome was found to be nearly 44 million bases in size, which is similar to that of four other Fusarium genomes that have been sequenced elsewhere. The genome contains just over 15 000 open reading frames, which is less than that of the related species, Fusarium oxysporum, but more than that for Fusarium verticillioides. Amongst the various putative gene clusters identified in F. circinatum, those encoding the secondary metabolites fumosin and fusarin appeared to harbour evidence of gene translocation. It is anticipated that similar comparisons of other loci will provide insights into the genetic basis for pathogenicity of the pitch canker pathogen. Perhaps more importantly, this project has engaged a relatively large group of scientists

  17. Preliminary design analysis of the ALT-II limiter for TEXTOR

    International Nuclear Information System (INIS)

    Koski, J.A.; Boyd, R.D.; Kempka, S.M.; Romig, A.D. Jr.; Smith, M.F.; Watson, R.D.; Whitley, J.B.; Conn, R.W.; Grotz, S.P.

    1984-01-01

    Installation of a large toroidal belt pump limiter, Advanced Limiter Test II (ALT-II), on the TEXTOR tokamak at Juelich, FRG is anticipated for early 1986. This paper discusses the preliminary mechanical design and materials considerations undertaken as part of the feasibility study phase for ALT-II. Since the actively cooled limiter blade is the component in direct contact with the plasma edge, and thus subject to the severe plasma environment, most preliminary design efforts have concentrated on analysis of the blade. The screening process which led to the recommended preliminary design consisting of a dispersion strenghthened copper or OFHC copper cover plate over an austenitic stainless steel base plate is discussed. A 1 to 3 mm thick low atomic number coating consisting of a graded plasma-sprayed Silicon Carbide-Aluminium composite is recommended subject to further experiment and evaluation. Thermal-hydraulic and stress analyses of the limiter blade are also discussed. (orig.)

  18. ORNL: PWR-BDHT analysis procedure, a preliminary overview

    International Nuclear Information System (INIS)

    Cliff, S.B.

    1978-01-01

    The computer programs currently used in the analysis of the ORNL-PWR Blowdown Heat Transfer Separate-Effects Program are overviewed. The current linkages and relationships among the programs are given along with general comments about the future directions of some of these programs. The overview is strictly from the computer science point of view with only minimal information concerning the engineering aspects of the analysis procedure

  19. Square root metric in the analysis of the measurements of high energy physics instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Petrillo, L; Severi, M [Istituto Nazionale di Fisica Nucleare, Rome (Italy); Rome Univ. (Italy). Ist. di Fisica)

    1982-09-15

    A vast category of detectors are characterized by a charge output with a distribution which has a variance proportional to the mean value. In all these cases a square root scale achieved in the hardware seems more suitable from the point of view of the resolution of the measurements, of the number of ADC channels needed, and of a preliminary analysis in the stage of tuning and checking of the detector.

  20. Failure mode analysis of preliminary design of ITER divertor impurity monitor

    International Nuclear Information System (INIS)

    Kitazawa, Sin-iti; Ogawa, Hiroaki

    2016-01-01

    Highlights: • Divertor impurity influx monitor for ITER (DIM) is procured by JADA. • DIM is designed to observe light from nuclear fusion plasma directly. • DIM is under preliminary design phase. • Failure mode of DIM was prepared for RAMI analysis. • RAMI analysis on DIM was performed to reduce technical risks. - Abstract: The objective of the divertor impurity influx monitor (DIM) for ITER is to measure the parameters of impurities and hydrogen isotopes (tritium, deuterium, and hydrogen) in divertor plasma using visible and UV spectroscopic techniques in the 200–1000 nm wavelength range. In ITER, special provisions are required to ensure accuracy and full functionality of the diagnostic components under harsh conditions (high temperature, high magnetic field, high vacuum condition, and high radiation field). Japan Domestic Agency is preparing the preliminary design of the ITER DIM system, which will be installed in the upper, equatorial and lower ports. The optical and mechanical designs of the DIM are conducted to fit ITER’s requirements. The optical and mechanical designs meet the requirements of spatial resolution. Some auxiliary systems were examined via prototyping. The preliminary design of the ITER DIM system was evaluated by RAMI analysis. The availability of the designed system is adequately high to satisfy the project requirements. However, some equipment does not have certain designs, and this may cause potential technical risks. The preliminary design should be modified to reduce technical risks and to prepare the final design.

  1. Summary of the Preliminary Analysis of Savannah River Depleted Uranium Trioxide

    International Nuclear Information System (INIS)

    2010-01-01

    This report summarizes a preliminary special analysis of the Savannah River Depleted Uranium Trioxide waste stream (SVRSURANIUM03, Revision 2). The analysis is considered preliminary because a final waste profile has not been submitted for review. The special analysis is performed to determine the acceptability of the waste stream for shallow land burial at the Area 5 Radioactive Waste Management Site (RWMS) at the Nevada National Security Site (NNSS). The Savannah River Depleted Uranium Trioxide waste stream requires a special analysis because the waste stream's sum of fractions exceeds one. The 99Tc activity concentration is 98 percent of the NNSS Waste Acceptance Criteria and the largest single contributor to the sum of fractions.

  2. Analysis of a spacecraft instrument ball bearing assembly lubricated by a perfluoroalkylether

    Science.gov (United States)

    Morales, W.; Jones, W. R., Jr.; Buckley, D. H.

    1986-01-01

    An analysis of a spacecraft instrument ball bearing assembly, subjected to a scanning life test, was performed to determine the possible case of rotational problems involving these units aboard several satellites. The analysis indicated an ineffective transfer of a fluorinated liquid lubricant from a phenolic retainer to the bearing balls. Part of the analysis led to a novel HPLC separation method employing a fluorinated mobile phase in conjunction with silica based size exclusion columns.

  3. Preliminary Analysis of the (Process and Product) Quality of Physical Education in Flemish Secondary Schools: Implementation of IKLO

    Science.gov (United States)

    Huts, K.; Van Hoecke, J.; De Knop, P.; Theeboom, M.

    2009-01-01

    The purpose of the present study was twofold, namely implementing a multifunctional (self-) evaluation instrument for physical education in a sample of Flemish secondary schools (N=100), while simultaneously obtaining a preliminary picture of the subjects' product and process quality. Descriptive statistics revealed that P. E. teachers' engagement…

  4. Bioelectrical impedance analysis for bovine milk: Preliminary results

    Science.gov (United States)

    Bertemes-Filho, P.; Valicheski, R.; Pereira, R. M.; Paterno, A. S.

    2010-04-01

    This work reports the investigation and analysis of bovine milk quality by using biological impedance measurements using electrical impedance spectroscopy (EIS). The samples were distinguished by a first chemical analysis using Fourier transform midinfrared spectroscopy (FTIR) and flow citometry. A set of milk samples (100ml each) obtained from 17 different cows in lactation with and without mastitis were analyzed with the proposed technique using EIS. The samples were adulterated by adding distilled water and hydrogen peroxide in a controlled manner. FTIR spectroscopy and flow cytometry were performed, and impedance measurements were made in a frequency range from 500Hz up to 1MHz with an implemented EIS system. The system's phase shift was compensated by measuring saline solutions. It was possible to show that the results obtained with the Bioelectrical Impedance Analysis (BIA) technique may detect changes in the milk caused by mastitis and the presence of water and hydrogen peroxide in the bovine milk.

  5. Application of instrumental neutron activation analysis to study ceramic fragments from Damascus Castle site, Syria

    International Nuclear Information System (INIS)

    Bakraji, E.H.

    2005-01-01

    Thirty-three archaeological ceramic fragment samples from Damascus Castle archaeological site, Damascus city, Syria, were analyzed using instrumental neutron activation analysis (INAA). 36 elements were determined. These elemental concentrations have been processed using two multivariate statistical methods, cluster and factor analysis in order to determine similarities and correlation between the various samples. Factor analysis confirms that 84.8% of the ceramics samples classified by cluster analysis are correctly classified by cluster analysis. The results provided persuasive evidence that Castle pottery used at least four different clay sources. Moreover, by means of systematic local analysis it will be clear whether these sources are local or not. (author)

  6. Data acquisition instruments: Psychopharmacology

    Energy Technology Data Exchange (ETDEWEB)

    Hartley, D.S. III

    1998-01-01

    This report contains the results of a Direct Assistance Project performed by Lockheed Martin Energy Systems, Inc., for Dr. K. O. Jobson. The purpose of the project was to perform preliminary analysis of the data acquisition instruments used in the field of psychiatry, with the goal of identifying commonalities of data and strategies for handling and using the data in the most advantageous fashion. Data acquisition instruments from 12 sources were provided by Dr. Jobson. Several commonalities were identified and a potentially useful data strategy is reported here. Analysis of the information collected for utility in performing diagnoses is recommended. In addition, further work is recommended to refine the commonalities into a directly useful computer systems structure.

  7. Isolation and preliminary function analysis of a Na + /H + antiporter ...

    African Journals Online (AJOL)

    A full-length cDNA Na+/H+ antiporter gene (MzNHX1) was isolated from Malus zumi according to the homologous Na+/H+ antiporter gene region in plants. Sequence analysis indicated that the cDNA was 2062 bp in length, including an open reading frame (ORF) of 1629 bp, which encoded a predicted polypeptide of 542 ...

  8. A Preliminary Analysis of a Behavioral Classrooms Needs Assessment

    Science.gov (United States)

    Leaf, Justin B.; Leaf, Ronald; McCray, Cynthia; Lamkins, Carol; Taubman, Mitchell; McEachin, John; Cihon, Joseph H.

    2016-01-01

    Today many special education classrooms implement procedures based upon the principles of Applied Behavior Analysis (ABA) to establish educationally relevant skills and decrease aberrant behaviors. However, it is difficult for school staff and consultants to evaluate the implementation of various components of ABA and general classroom set up. In…

  9. Frequency-Zooming ARMA Modeling for Analysis of Noisy String Instrument Tones

    Directory of Open Access Journals (Sweden)

    Paulo A. A. Esquef

    2003-09-01

    Full Text Available This paper addresses model-based analysis of string instrument sounds. In particular, it reviews the application of autoregressive (AR modeling to sound analysis/synthesis purposes. Moreover, a frequency-zooming autoregressive moving average (FZ-ARMA modeling scheme is described. The performance of the FZ-ARMA method on modeling the modal behavior of isolated groups of resonance frequencies is evaluated for both synthetic and real string instrument tones immersed in background noise. We demonstrate that the FZ-ARMA modeling is a robust tool to estimate the decay time and frequency of partials of noisy tones. Finally, we discuss the use of the method in synthesis of string instrument sounds.

  10. Pilot Workload and Speech Analysis: A Preliminary Investigation

    Science.gov (United States)

    Bittner, Rachel M.; Begault, Durand R.; Christopher, Bonny R.

    2013-01-01

    Prior research has questioned the effectiveness of speech analysis to measure the stress, workload, truthfulness, or emotional state of a talker. The question remains regarding the utility of speech analysis for restricted vocabularies such as those used in aviation communications. A part-task experiment was conducted in which participants performed Air Traffic Control read-backs in different workload environments. Participant's subjective workload and the speech qualities of fundamental frequency (F0) and articulation rate were evaluated. A significant increase in subjective workload rating was found for high workload segments. F0 was found to be significantly higher during high workload while articulation rates were found to be significantly slower. No correlation was found to exist between subjective workload and F0 or articulation rate.

  11. Preliminary analysis of productivity of fruiting fungi on Strzeleckie meadows

    Directory of Open Access Journals (Sweden)

    Barbara Sadowska

    2014-11-01

    Full Text Available Analysis demonstrated that the fresh ahd dry weight as well as the ash content of fungal fruit bodies collected on a forest-surrounded unmown meadow (Stellario-Deschampsietum Freitag 1957 and Caricetum elatae W.Koch 1926 were lower than the same values for a plot of exploited mown meadow and higher than on an exploited unmown meadow (Arrhenatheretum medioeuropaeum (Br.-Bl. Oberd. 1952.

  12. Preliminary analysis on incore performance of nuclear fuel: pt. 4

    International Nuclear Information System (INIS)

    Noh, S.K.; Chang, M.H.; Lee, C.C.; Chung, Y.H.; Kuk, K.Y.; Park, C.Y.; Lee, S.K.

    1981-01-01

    An analysis has been performed for thermal hydraulic design parameters of Wolsung-1 reactor core in steady state with the help of a computer code COBRA-IV-I. The design parameters are coolant enthalpy, flow velocity, coolant quality, pressure and fuel temperature distribution. The maximum power channel has been taken into account in this work. The results appear to be reasonably agreeable with data from PSR'S, with the maximum difference between this work and PSR'S being 4.3%

  13. Job Search Success in Local Labour Markets - A Preliminary Analysis

    OpenAIRE

    Greig, Malcolm; McQuaid, Ronald W.

    2001-01-01

    This study tests the appropriateness of current government employment policies, in particular the New Deal, in targeting specific groups of unemployed jobseekers. A sample of 169 unemployed jobseekers is divided into those who were successful and unsuccessful in finding employment and each group is analysed in terms of their attributes. A factor analysis of these attributes is then carried out in order to develop typical profiles of unsuccessful jobseekers who are possibly in need of special ...

  14. Preliminary analysis of knee stress in Full Extension Landing

    Directory of Open Access Journals (Sweden)

    Majid Davoodi Makinejad

    2013-09-01

    Full Text Available OBJECTIVE: This study provides an experimental and finite element analysis of knee-joint structure during extended-knee landing based on the extracted impact force, and it numerically identifies the contact pressure, stress distribution and possibility of bone-to-bone contact when a subject lands from a safe height. METHODS: The impact time and loads were measured via inverse dynamic analysis of free landing without knee flexion from three different heights (25, 50 and 75 cm, using five subjects with an average body mass index of 18.8. Three-dimensional data were developed from computed tomography scans and were reprocessed with modeling software before being imported and analyzed by finite element analysis software. The whole leg was considered to be a fixed middle-hinged structure, while impact loads were applied to the femur in an upward direction. RESULTS: Straight landing exerted an enormous amount of pressure on the knee joint as a result of the body's inability to utilize the lower extremity muscles, thereby maximizing the threat of injury when the load exceeds the height-safety threshold. CONCLUSIONS: The researchers conclude that extended-knee landing results in serious deformation of the meniscus and cartilage and increases the risk of bone-to-bone contact and serious knee injury when the load exceeds the threshold safety height. This risk is considerably greater than the risk of injury associated with walking downhill or flexion landing activities.

  15. Implementation of picoSpin Benchtop NMR Instruments into Organic Chemistry Teaching Laboratories through Spectral Analysis of Fischer Esterification Products

    Science.gov (United States)

    Yearty, Kasey L.; Sharp, Joseph T.; Meehan, Emma K.; Wallace, Doyle R.; Jackson, Douglas M.; Morrison, Richard W.

    2017-01-01

    [Superscript 1]H NMR analysis is an important analytical technique presented in introductory organic chemistry courses. NMR instrument access is limited for undergraduate organic chemistry students due to the size of the instrument, price of NMR solvents, and the maintenance level required for instrument upkeep. The University of Georgia Chemistry…

  16. Analysis for preliminary evaluation of discrete fracture flow and large-scale permeability in sedimentary rocks

    International Nuclear Information System (INIS)

    Kanehiro, B.Y.; Lai, C.H.; Stow, S.H.

    1987-05-01

    Conceptual models for sedimentary rock settings that could be used in future evaluation and suitability studies are being examined through the DOE Repository Technology Program. One area of concern for the hydrologic aspects of these models is discrete fracture flow analysis as related to the estimation of the size of the representative elementary volume, evaluation of the appropriateness of continuum assumptions and estimation of the large-scale permeabilities of sedimentary rocks. A basis for preliminary analysis of flow in fracture systems of the types that might be expected to occur in low permeability sedimentary rocks is presented. The approach used involves numerical modeling of discrete fracture flow for the configuration of a large-scale hydrologic field test directed at estimation of the size of the representative elementary volume and large-scale permeability. Analysis of fracture data on the basis of this configuration is expected to provide a preliminary indication of the scale at which continuum assumptions can be made

  17. Preliminary RAMI analysis of DFLL TBS for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Dagui [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui, 230031 (China); University of Science and Technology of China, Hefei, Anhui, 230031 (China); Yuan, Run [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui, 230031 (China); Wang, Jiaqun, E-mail: jiaqun.wang@fds.org.cn [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui, 230031 (China); Wang, Fang; Wang, Jin [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui, 230031 (China)

    2016-11-15

    Highlights: • We performed the functional analysis of the DFLL TBS. • We performed a failure mode analysis of the DFLL TBS. • We estimated the reliability and availability of the DFLL TBS. • The ITER RAMI approach was applied to the DFLL TBS for technical risk control in the design phase. - Abstract: ITER is the first fusion machine fully designed to prove the physics and technological basis for next fusion power plants. Among the main technical objectives of ITER is to test and validate design concepts of tritium breeding blankets relevant to the fusion power plants. To achieve this goal, China has proposed the dual functional lithium-lead test blanket module (DFLL TBM) concept design. The DFLL TBM and its associated ancillary system were called DFLL TBS. The DFLL TBS play a key role in next fusion reactor. In order to ensure reliable and available of DFLL TBS, the risk control project of DFLL TBS has been put on the schedule. As the stage of the ITER technical risk control policy, the RAMI (Reliability, Availability, Maintainability, Inspectability) approach was used to control the technical risk of ITER. In this paper, the RAMI approach was performed on the conceptual design of DFLL TBS. A functional breakdown was prepared on DFLL TBS, and the system was divided into 3 main functions and 72 basic functions. Based on the result of functional breakdown of DFLL TBS, the reliability block diagrams were prepared to estimate the reliability and availability of each function under the stipulated operating conditions. The inherent availability of the DFLL TBS expected after implementation of mitigation actions was calculated to be 98.57% over 2 years based on the ITER reliability database. A Failure Modes Effects and Criticality Analysis (FMECA) was performed with criticality charts highlighting the risk level of the different failure modes with regard to their probability of occurrence and their effects on the availability.

  18. Preliminary safety analysis for key design features of KALIMER

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, D. H.; Kwon, Y. M.; Chang, W. P.; Suk, S. D.; Lee, S. O.; Lee, Y. B.; Jeong, K. S

    2000-07-01

    KAERI is currently developing the conceptual design of a liquid metal reactor, KALIMER(Korea Advanced Liquid Metal Reactor) under the long-term nuclear R and D program. In this report, descriptions of the KALIMER safety design features and safety analyses results for selected ATWS accidents are presented. First, the basic approach to achieve the safety goal is introduced in chapter 1, and the safety evaluation procedure for the KALIMER design is described in chapter 2. It includes event selection, event categorization, description of design basis events, and beyond design basis events. In chapter 3, results of inherent safety evaluations for the KALIMER conceptual design are presented. The KALIMER core and plant system are designed to assure design performance during a selected set of events without either reactor control or protection system intervention. Safety analyses for the postulated anticipated transient without scram(ATWS) have been performed to investigate the KALIMER system response to the events. They are categorized as bounding events(BEs) because of their low probability of occurrence. In chapter 4, the design of the KALIMER containment dome and the results of its performance analysis are presented. The designs of the existing LMR containment and the KALIMER containment dome have been compared in this chapter. Procedure of the containment performance analysis and the analysis results are described along with the accident scenario and source terms. Finally, a simple methodology is introduced to investigate the core kinetics and hydraulic behavior during HCDA in chapter 5. Mathematical formulations have been developed in the framework of the modified bethe-tait method, and scoping analyses have been performed for the KALIMER core behavior during super-prompt critical excursions.

  19. SeDA: A software package for the statistical analysis of the instrument drift

    International Nuclear Information System (INIS)

    Lee, H. J.; Jang, S. C.; Lim, T. J.

    2006-01-01

    The setpoints for safety-related equipment are affected by many sources of an uncertainty. ANSI/ISA-S67.04.01-2000 [1] and ISA-RP6 7.04.02-2000 [2] suggested the statistical approaches for ensuring that the safety-related instrument setpoints were established and maintained within the technical specification limits [3]. However, Jang et al. [4] indicated that the preceding methodologies for a setpoint drift analysis might be insufficient to manage a setpoint drift on an instrumentation device and proposed new statistical analysis procedures for the management of a setpoint drift, based on the plant specific as-found/as-left data. Although IHPA (Instrument History Performance Analysis) is a widely known commercial software package to analyze an instrument setpoint drift, several steps in the new procedure cannot be performed by using it because it is based on the statistical approaches suggested in the ANSI/ISA-S67.04.01 -2000 [1] and ISA-RP67.04.02-2000 [2], In this paper we present a software package (SeDA: Setpoint Drift Analysis) that implements new methodologies, and which is easy to use, as it is accompanied by powerful graphical tools. (authors)

  20. Bias and Bias Correction in Multisite Instrumental Variables Analysis of Heterogeneous Mediator Effects

    Science.gov (United States)

    Reardon, Sean F.; Unlu, Fatih; Zhu, Pei; Bloom, Howard S.

    2014-01-01

    We explore the use of instrumental variables (IV) analysis with a multisite randomized trial to estimate the effect of a mediating variable on an outcome in cases where it can be assumed that the observed mediator is the only mechanism linking treatment assignment to outcomes, an assumption known in the IV literature as the exclusion restriction.…

  1. Protein Analysis Using Real-Time PCR Instrumentation: Incorporation in an Integrated, Inquiry-Based Project

    Science.gov (United States)

    Southard, Jonathan N.

    2014-01-01

    Instrumentation for real-time PCR is used primarily for amplification and quantitation of nucleic acids. The capability to measure fluorescence while controlling temperature in multiple samples can also be applied to the analysis of proteins. Conformational stability and changes in stability due to ligand binding are easily assessed. Protein…

  2. Coulometric Titration of Ethylenediaminetetraacetate (EDTA) with Spectrophotometric Endpoint Detection: An Experiment for the Instrumental Analysis Laboratory

    Science.gov (United States)

    Williams, Kathryn R.; Young, Vaneica Y.; Killian, Benjamin J.

    2011-01-01

    Ethylenediaminetetraacetate (EDTA) is commonly used as an anticoagulant in blood-collection procedures. In this experiment for the instrumental analysis laboratory, students determine the quantity of EDTA in commercial collection tubes by coulometric titration with electrolytically generated Cu[superscript 2+]. The endpoint is detected…

  3. A new type on line fast analysis instrument of uranium ore grade

    International Nuclear Information System (INIS)

    Guo Maojin.

    1992-01-01

    The instrument is used to analyse the average grade of uranium ore on the belt. Its average analysis speed is about 300 t/h. The physical mechanism of measurement, characteristics, principle of operation and applications in several years are described. The CMOS LSI IC are adopted. The stability, reliability and anti-interference ability are very good

  4. Instrument and Survey Analysis Technical Report: Program Implementation Survey. Technical Report #1112

    Science.gov (United States)

    Alonzo, Julie; Tindal, Gerald

    2011-01-01

    This technical document provides guidance to educators on the creation and interpretation of survey instruments, particularly as they relate to an analysis of program implementation. Illustrative examples are drawn from a survey of educators related to the use of the easyCBM learning system. This document includes specific sections on…

  5. Trace elements in Turkish tobacco determined by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Guelovali, M.C.; Guenduez, G.

    1983-01-01

    The concentration of 20 trace elements in nine brands of Turkish cigarette tobacco and in a brand of pipe tobacco ash has been determined by instrumental neutron activation analysis. The percent transference of elements into smoke has been estimated from the amounts remaining in the ash. (author)

  6. Bringing in the Bard: Shakespearean Plays as Context for Instrumental Analysis Projects

    Science.gov (United States)

    Kloepper, Kathryn D.

    2015-01-01

    Scenes from the works of William Shakespeare were incorporated into individual and group projects for an upper-level chemistry class, instrumental analysis. Students read excerpts from different plays and then viewed a corresponding video clip from a stage or movie production. Guided-research assignments were developed based on these scenes. These…

  7. Trace element concentrations in human bone using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    El-Amri, F.A.; El-Kabroun, M.A.R.

    1997-01-01

    Instrumental neutron activation analysis has been applied to analyze 23 bone samples obtained from Libyan patient aged (3-80) years for the study of the concentration levels of trace elements Ba, Br, Ca, Fe, Sr and Zn and their concentration patterns regarding to the age and sex of the patients. (author)

  8. Flavour Profiling of 'Marion' and Thornless Blackberries by Instrumental and Sensory Analysis

    Science.gov (United States)

    The flavour of thornless blackberries grown in Pacific Northwest including 'Thornless Evergreen', 'Black Diamond', 'Black Pearl', 'Nightfall', ORUS 1843-3, 'Waldo', NZ 9351-4, and 'Chester Thornless' as well as 'Marion' was profiled by sensory evaluation and instrumental analysis. Sensory results sh...

  9. A survey of environmental exposure amongst locoshed workers by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Singh, V.K.N.; Garg, A.N.

    1995-01-01

    Instrumental neutron activation analysis (INAA) has been used for the determination of 16 elements in hair of locoshed workers (n=10) to study environmental exposure. A comparison of mean elemental contents with control (n=11) shows a significant enhancement for Cr, Th, Ca, Se and Na whereas Br and Sb show a declining trend. (author). 4 refs., 1 tab

  10. Black Boxes in Analytical Chemistry: University Students' Misconceptions of Instrumental Analysis

    Science.gov (United States)

    Carbo, Antonio Domenech; Adelantado, Jose Vicente Gimeno; Reig, Francisco Bosch

    2010-01-01

    Misconceptions of chemistry and chemical engineering university students concerning instrumental analysis have been established from coordinated tests, tutorial interviews and laboratory lessons. Misconceptions can be divided into: (1) formal, involving specific concepts and formulations within the general frame of chemistry; (2)…

  11. An Exploratory Factor Analysis and Reliability Analysis of the Student Online Learning Readiness (SOLR) Instrument

    Science.gov (United States)

    Yu, Taeho; Richardson, Jennifer C.

    2015-01-01

    The purpose of this study was to develop an effective instrument to measure student readiness in online learning with reliable predictors of online learning success factors such as learning outcomes and learner satisfaction. The validity and reliability of the Student Online Learning Readiness (SOLR) instrument were tested using exploratory factor…

  12. Computer content analysis of schizophrenic speech: a preliminary report.

    Science.gov (United States)

    Tucker, G J; Rosenberg, S D

    1975-06-01

    Computer analysis significantly differtiated the thermatic content of the free speech of 10 schizophrenic patients from that of 10 nonschizophrenic patients and from the content of transcripts of dream material from 10 normal subjects. Schizophrenic patients used the thematic categories in factor 1 (the "schizophrenic factor") 3 times more frequently than the nonschizophrenics and 10 times more frequently than the normal subjects (p smaller than 01). In general, the language content of the schizophrenic patient mirrored an almost agitated attempt to locate oneself in time and space and to defend against internal discomfort and confusion. The authors discuss the implications of this study for future research.

  13. Preliminary report on the PIXE analysis of the squid statoliths

    International Nuclear Information System (INIS)

    Ikeda, Yuzuru; Arai, Nobuaki; Sakamoto, Wataru; Murayama, Tatsuro; Maeda, Kuniko; Yoshida, Koji.

    1996-01-01

    Micro trace elements in the squid statolith, a calcareous stone which acts as a balancer and hearing, was analyzed with Particle Induced X-ray Emission (PIXE) for the Japanese common squid for the first time. Calcium is the main component of the squid statoliths, which means that squid statolith is the pure calcified structure similar to the fish otolith. Beside Ca, Sr was detected with strong dosage, and some other elements as Mn, Fe, Cu, Zn and As were also detected. Possible assumption of intake of microelements to the statoliths and the suitability of PIXE for statoliths analysis are discussed. (author)

  14. Macroalgae as a Biomass Feedstock: A Preliminary Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Roesijadi, Guritno; Jones, Susanne B.; Snowden-Swan, Lesley J.; Zhu, Yunhua

    2010-09-26

    A thorough of macroalgae analysis as a biofuels feedstock is warranted due to the size of this biomass resource and the need to consider all potential sources of feedstock to meet current biomass production goals. Understanding how to harness this untapped biomass resource will require additional research and development. A detailed assessment of environmental resources, cultivation and harvesting technology, conversion to fuels, connectivity with existing energy supply chains, and the associated economic and life cycle analyses will facilitate evaluation of this potentially important biomass resource.

  15. Preliminary safety analysis report for the Waste Characterization Facility

    International Nuclear Information System (INIS)

    1994-10-01

    This safety analysis report outlines the safety concerns associated with the Waste Characterization Facility located in the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. The three main objectives of the report are to: define and document a safety basis for the Waste Characterization Facility activities; demonstrate how the activities will be carried out to adequately protect the workers, public, and environment; and provide a basis for review and acceptance of the identified risk that the managers, operators, and owners will assume. 142 refs., 38 figs., 39 tabs

  16. Application of instrumental neutron activation analysis and multivariate statistical methods to archaeological Syrian ceramics

    International Nuclear Information System (INIS)

    Bakraji, E. H.; Othman, I.; Sarhil, A.; Al-Somel, N.

    2002-01-01

    Instrumental neutron activation analysis (INAA) has been utilized in the analysis of thirty-seven archaeological ceramics fragment samples collected from Tal AI-Wardiate site, Missiaf town, Hamma city, Syria. 36 chemical elements were determined. These elemental concentrations have been processed using two multivariate statistical methods, cluster and factor analysis in order to determine similarities and correlation between the various samples. Factor analysis confirms that samples were correctly classified by cluster analysis. The results showed that samples can be considered to be manufactured using three different sources of raw material. (author)

  17. Preliminary uranium enrichment analysis results using cadmium zinc telluride detectors

    International Nuclear Information System (INIS)

    Lavietes, A.D.; McQuaid, J.H.; Paulus, T.J.

    1995-01-01

    Lawrence Livermore National Laboratory (LLNL) and EG ampersand G ORTEC have jointly developed a portable ambient-temperature detection system that can be used in a number of application scenarios. The detection system uses a planar cadmium zinc telluride (CZT) detector with custom-designed detector support electronics developed at LLNL and is based on the recently released MicroNOMAD multichannel analyzer (MCA) produced by ORTEC. Spectral analysis is performed using software developed at LLNL that was originally designed for use with high-purity germanium (HPGe) detector systems. In one application, the CZT detection system determines uranium enrichments ranging from less than 3% to over 75% to within accuracies of 20%. The analysis was performed using sample sizes of 200 g or larger and acquisition times of 30 min. The authors have demonstrated the capabilities of this system by analyzing the spectra gathered by the CZT detection system from uranium sources of several enrichments. These experiments demonstrate that current CZT detectors can, in some cases, approach performance criteria that were previously the exclusive domain of larger HPGe detector systems

  18. RoboSCell: An automated single cell arraying and analysis instrument

    KAUST Repository

    Sakaki, Kelly

    2009-09-09

    Single cell research has the potential to revolutionize experimental methods in biomedical sciences and contribute to clinical practices. Recent studies suggest analysis of single cells reveals novel features of intracellular processes, cell-to-cell interactions and cell structure. The methods of single cell analysis require mechanical resolution and accuracy that is not possible using conventional techniques. Robotic instruments and novel microdevices can achieve higher throughput and repeatability; however, the development of such instrumentation is a formidable task. A void exists in the state-of-the-art for automated analysis of single cells. With the increase in interest in single cell analyses in stem cell and cancer research the ability to facilitate higher throughput and repeatable procedures is necessary. In this paper, a high-throughput, single cell microarray-based robotic instrument, called the RoboSCell, is described. The proposed instrument employs a partially transparent single cell microarray (SCM) integrated with a robotic biomanipulator for in vitro analyses of live single cells trapped at the array sites. Cells, labeled with immunomagnetic particles, are captured at the array sites by channeling magnetic fields through encapsulated permalloy channels in the SCM. The RoboSCell is capable of systematically scanning the captured cells temporarily immobilized at the array sites and using optical methods to repeatedly measure extracellular and intracellular characteristics over time. The instrument\\'s capabilities are demonstrated by arraying human T lymphocytes and measuring the uptake dynamics of calcein acetoxymethylester-all in a fully automated fashion. © 2009 Springer Science+Business Media, LLC.

  19. Yucca Mountain transportation routes: Preliminary characterization and risk analysis

    International Nuclear Information System (INIS)

    Souleyrette, R.R. II; Sathisan, S.K.; di Bartolo, R.

    1991-01-01

    In this study, rail and highway routes which may be used for shipments of high-level nuclear waste to a proposed repository at Yucca Mountain, Nevada are characterized. This characterization facilitates three types of impact analysis: comparative study, limited worst-case assessment, and more sophisticated probabilistic risk assessment techniques. Data for relative and absolute impact measures are provided to support comparisons of routes based on selected characteristics. A worst-case scenario assessment is included to determine potentially critical and most likely places for accidents or incidents to occur. The assessment facilitated by the data in this study is limited because impact measures are restricted to the identification of potential areas or persons affected. No attempt is made to quantify the magnitude of these impacts. Most likely locations for accidents to occur are determined relative to other locations within the scope of this study. Independent factors and historical trends used to identify these likely locations are only proxies for accident probability

  20. City of Hoboken Energy Surety Analysis: Preliminary Design Summary

    Energy Technology Data Exchange (ETDEWEB)

    Stamp, Jason Edwin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Military and Energy Systems Analysis Dept.; Baca, Michael J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Military and Energy Systems Analysis Dept.; Munoz-Ramos, Karina [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Military and Energy Systems Analysis Dept.; Schenkman, Benjamin L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Military and Energy Systems Analysis Dept.; Eddy, John P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Systems Readiness and Sustainment Technology Dept.; Smith, Mark A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Systems Readiness and Sustainment Technology Dept.; Guttromson, Ross [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electric Power Systems Research Dept.; Henry, Jordan M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Critical Infrastructure Systems Dept.; Jensen, Richard Pearson [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Geomechanics Dept.

    2014-09-01

    In 2012, Hurricane Sandy devastated much of the U.S. northeast coastal areas. Among those hardest hit was the small community of Hoboken, New Jersey, located on the banks of the Hudson River across from Manhattan. This report describes a city-wide electrical infrastructure design that uses microgrids and other infrastructure to ensure the city retains functionality should such an event occur in the future. The designs ensure that up to 55 critical buildings will retain power during blackout or flooded conditions and include analysis for microgrid architectures, performance parameters, system control, renewable energy integration, and financial opportunities (while grid connected). The results presented here are not binding and are subject to change based on input from the Hoboken stakeholders, the integrator selected to manage and implement the microgrid, or other subject matter experts during the detailed (final) phase of the design effort.

  1. The Σ − D relation for planetary nebulae: Preliminary analysis

    Directory of Open Access Journals (Sweden)

    Urošević D.

    2007-01-01

    Full Text Available An analysis of the relation between radio surface brightness and diameter, so-called Σ − D relation, for planetary nebulae (PNe is presented: i the theoretical Σ − D relation for the evolution of bremsstrahlung surface brightness is derived; ii contrary to the results obtained earlier for the Galactic supernova remnant (SNR samples, our results show that the updated sample of Galactic PNe does not severely suffer from volume selection effect - Malmquist bias (same as for the extragalactic SNR samples and; iii we conclude that the empirical S − D relation for PNe derived in this paper is not useful for valid determination of distances for all observed PNe with unknown distances. .

  2. Multielement analysis of rice flour-unpolished reference material by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Suzuki, Shogo; Hirai, Shoji

    1990-01-01

    Trace elements in NIES certified reference material No. 10-a∼10-c Rice Flour-Unpolished, prepared by the National Institute for Environmental Studies of Japan (NIES), were determined by instrumental neutron activation analysis (INAA). A set of three samples with different Cd concentration levels was subjected to analyses. Portions of each sample (ca. 200∼1000 mg) were irradiated, either with thermal neutrons without cadmium filter or with epithermal neutrons with cadmium filter, in the Musashi Institute of Technology Research Reactor (MITRR). The activated samples were analyzed by the three methods; conventional γ-ray spectrometry using a coaxial Ge detector, anticoincidence counting spectrometry, and coincidence counting spectrometry using a coaxial Ge detector and a well type NaI(Tl) detector. Concentrations of 26∼28 elements were determined by these methods. The values obtained for many elements, except for Mg and K, were in good agreement with those of the NIES certified and reference. Concentrations of 10 elements (S, Sc, V, Ag, Sb, Cs, Ba, La, Sm, Th), whose certified or reference values are not available from NIES, were also determined in this work. (author)

  3. A Preliminary Tsunami Vulnerability Analysis for Yenikapi Region in Istanbul

    Science.gov (United States)

    Ceren Cankaya, Zeynep; Suzen, Lutfi; Cevdet Yalciner, Ahmet; Kolat, Cagil; Aytore, Betul; Zaytsev, Andrey

    2015-04-01

    One of the main requirements during post disaster recovery operations is to maintain proper transportation and fluent communication at the disaster areas. Ports and harbors are the main transportation hubs which must work with proper performance at all times especially after the disasters. Resilience of coastal utilities after earthquakes and tsunamis have major importance for efficient and proper rescue and recovery operations soon after the disasters. Istanbul is a mega city with its various coastal utilities located at the north coast of the Sea of Marmara. At Yenikapi region of Istanbul, there are critical coastal utilities and vulnerable coastal structures and critical activities occur daily. Fishery ports, commercial ports, small craft harbors, passenger terminals of intercity maritime transportation, water front commercial and/or recreational structures are some of the examples of coastal utilization which are vulnerable against marine disasters. Therefore their vulnerability under tsunami or any other marine hazard to Yenikapi region of Istanbul is an important issue. In this study, a methodology of vulnerability analysis under tsunami attack is proposed with the applications to Yenikapi region. In the study, high resolution (1m) GIS database of Istanbul Metropolitan Municipality (IMM) is used and analyzed by using GIS implementation. The bathymetry and topography database and the vector dataset containing all buildings/structures/infrastructures in the study area are obtained for tsunami numerical modeling for the study area. GIS based tsunami vulnerability assessment is conducted by applying the Multi-criteria Decision Making Analysis (MCDA). The tsunami parameters from deterministically defined worst case scenarios are computed from the simulations using tsunami numerical model NAMI DANCE. The vulnerability parameters in the region due to two different classifications i) vulnerability of buildings/structures and ii) vulnerability of (human) evacuation

  4. Preliminary analysis of Psoroptes ovis transcriptome in different developmental stages

    Directory of Open Access Journals (Sweden)

    Man-Li He

    2016-11-01

    Full Text Available Abstract Background Psoroptic mange is a chronic, refractory, contagious and infectious disease mainly caused by the mange mite Psoroptes ovis, which can infect horses, sheep, buffaloes, rabbits, other domestic animals, deer, wild camels, foxes, minks, lemurs, alpacas, elks and other wild animals. Features of the disease include intense pruritus and dermatitis, depilation and hyperkeratosis, which ultimately result in emaciation or death caused by secondary bacterial infections. The infestation is usually transmitted by close contact between animals. Psoroptic mange is widespread in the world. In this paper, the transcriptome of P. ovis is described following sequencing and analysis of transcripts from samples of larvae (i.e. the Pso_L group and nymphs and adults (i.e. the Pso_N_A group. The study describes differentially expressed genes (DEGs and genes encoding allergens, which help understanding the biology of P. ovis and lay foundations for the development of vaccine antigens and drug target screening. Methods The transcriptome of P. ovis was assembled and analyzed using bioinformatic tools. The unigenes of P. ovis from each developmental stage and the unigenes differentially between developmental stages were compared with allergen protein sequences contained in the allergen database website to predict potential allergens. Results We identified 38,836 unigenes, whose mean length was 825 bp. On the basis of sequence similarity with seven databases, a total of 17,366 unigenes were annotated. A total of 1,316 DEGs were identified, including 496 upregulated and 820 downregulated in the Pso_L group compared with the Pso_N_A group. We predicted 205 allergens genes in the two developmental stages similar to genes from other mites and ticks, of these, 14 were among the upregulated DEGs and 26 among the downregulated DEGs. Conclusion This study provides a reference transcriptome of P. ovis in absence of a reference genome. The analysis of DEGs and

  5. Preliminary analysis of a new IAEA lichen AQCS material

    International Nuclear Information System (INIS)

    Grass, F.; Bichler, M.; Dorner, J.; Ismail, S.; Kregshammer, P.; Zamini, S.; Gwozdz, R.

    2000-01-01

    Lichen with a higher content on interesting trace elements were analyzed by activation analysis and by X-RF measurements on pressed lichen samples. The activation analyses were performed in three different ways: Short-time AA in the Fast Irradiation and Measurement System. Up to 580mg of lichen were irradiated 5-300s in polyethylene containers. Single spectra and spectra of 6 samples were summed up and evaluated. Longer irradiation at the ASTRA-Reactor: 2h at 8E13/s cm 2 . 100-150mg of lichen were irradiated in quartz suprasil vials. Longer irradiation at the Institute's TRIGA-Reactor: 6-7h at 1.8E12/s cm 2 , sample size: 7-48g of lichen were irradiated in polyethylene containers and after irradiation transferred to new measurement containers and measured in a device constructed by Gwozdz. The X-RF analysis was performed with a Spectrace 5000 energy dispersive X-ray fluorescence analyzer with a rhodium anode tube for excitation. From the activation analyses, the following elements were determined: Ag, Al, As, Au, Ba, Br, Ca, Cd, Ce, Cl, Co, Cr, Cs, Cu, Dy, Eu, Fe, Hf, Hg, I, K, La, Lu, Mg, Mn, Mo, Na, Nd, Ni, Rb, Sb, Sc, Se, Sr, Ta, Tb, Th, Ti, U, V, Yb, Zn. From the X-RF measurements, the elements Ag, Al, Ba, Br, Ca, Cd, Cu, Fe, I, K, Mg, Mn, P, Pb, Rb, S, Sb, Si, Sn, Sr, Ti, Y, Zn, and Zr were evaluated. From the X-RF data as well as from the AA-data of samples of different weight it is apparent that milling to a particle size of 200m is not sufficient for all elements, especially not for gold, cadmium, and cobalt which may be present as nuggets or accessory heavy minerals. It is therefore advisable to mill the sample to a particle size which is an order of magnitude smaller and remove the not adhering dust, even if this lowers the content of these elements. (author)

  6. Preliminary results of standard quantitative analysis by ED-XRF

    Energy Technology Data Exchange (ETDEWEB)

    Lara, Alessandro L. de; Franca, Alana C.; Neto, Manoel R.M.; Paschuk, Sergei A., E-mail: alellara@hotmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Dept. de Fisica; Denyak, Valeriy, E-mail: denyak@gmail.com [Instituto de Pesquisa Pele Pequeno Principe (IPPP), Curitiba, PR (Brazil)

    2013-07-01

    A comparison between the results of elemental concentration proposed by XRS-FP software , using data obtained by EDXRF technique with those obtained by stoichiometric calculation was performed. For this purpose, five standard samples of known compounds were produced: two lead- oxide, magnesium chloride and iodine in controlled amounts. The compounds were subsequently mixed and compressed to form tablets. The samples were irradiated in three endpoints, according to an orientation. The measurements were performed at the Laboratory for Radiological UTFPR using X-123SDD the Amptek detector and X-ray tube with silver target from the same manufacturer. The operating conditions tube were 05μA current to a 40 kV voltage. Finally, the 15 spectra analyzed with the software to determine the concentration of chlorine, iodine and lead. Data from this analysis were compared with results expected in stoichiometric calculations. The data provided by the program, a convergence of results, indicating homogeneity of the samples was found. Compared to the stoichiometric calculation, a considerable discrepancy that may be the result of a misconfiguration or contamination of the sample was found. At the end, we created a proposal for continuation of the work using an auxiliary calculation should be developed in the next step.

  7. A preliminary study of DTI Fingerprinting on stroke analysis.

    Science.gov (United States)

    Ma, Heather T; Ye, Chenfei; Wu, Jun; Yang, Pengfei; Chen, Xuhui; Yang, Zhengyi; Ma, Jingbo

    2014-01-01

    DTI (Diffusion Tensor Imaging) is a well-known MRI (Magnetic Resonance Imaging) technique which provides useful structural information about human brain. However, the quantitative measurement to physiological variation of subtypes of ischemic stroke is not available. An automatically quantitative method for DTI analysis will enhance the DTI application in clinics. In this study, we proposed a DTI Fingerprinting technology to quantitatively analyze white matter tissue, which was applied in stroke classification. The TBSS (Tract Based Spatial Statistics) method was employed to generate mask automatically. To evaluate the clustering performance of the automatic method, lesion ROI (Region of Interest) is manually drawn on the DWI images as a reference. The results from the DTI Fingerprinting were compared with those obtained from the reference ROIs. It indicates that the DTI Fingerprinting could identify different states of ischemic stroke and has promising potential to provide a more comprehensive measure of the DTI data. Further development should be carried out to improve DTI Fingerprinting technology in clinics.

  8. FFTF vertical sodium storage tank preliminary thermal analysis

    International Nuclear Information System (INIS)

    Irwin, J.J.

    1995-01-01

    In the FFTF Shutdown Program, sodium from the primary and secondary heat transport loops, Interim Decay Storage (IDS), and Fuel Storage Facility (FSF) will be transferred to four large storage tanks for temporary storage. Three of the storage tanks will be cylindrical vertical tanks having a diameter of 28 feet, height of 22 feet and fabricated from carbon steel. The fourth tank is a horizontal cylindrical tank but is not the subject of this report. The storage tanks will be located near the FFTF in the 400 Area and rest on a steel-lined concrete slab in an enclosed building. The purpose of this work is to document the thermal analyses that were performed to ensure that the vertical FFTF sodium storage tank design is feasible from a thermal standpoint. The key criterion for this analysis is the time to heat up the storage tank containing frozen sodium at ambient temperature to 400 F. Normal operating conditions include an ambient temperature range of 32 F to 120 F. A key parameter in the evaluation of the sodium storage tank is the type of insulation. The baseline case assumed six inches of calcium silicate insulation. An alternate case assumed refractory fiber (Cerablanket) insulation also with a thickness of six inches. Both cases assumed a total electrical trace heat load of 60 kW, with 24 kW evenly distributed on the bottom head and 36 kW evenly distributed on the tank side wall

  9. Preliminary analysis of the proposed BN-600 benchmark core

    International Nuclear Information System (INIS)

    John, T.M.

    2000-01-01

    The Indira Gandhi Centre for Atomic Research is actively involved in the design of Fast Power Reactors in India. The core physics calculations are performed by the computer codes that are developed in-house or by the codes obtained from other laboratories and suitably modified to meet the computational requirements. The basic philosophy of the core physics calculations is to use the diffusion theory codes with the 25 group nuclear cross sections. The parameters that are very sensitive is the core leakage, like the power distribution at the core blanket interface etc. are calculated using transport theory codes under the DSN approximations. All these codes use the finite difference approximation as the method to treat the spatial variation of the neutron flux. Criticality problems having geometries that are irregular to be represented by the conventional codes are solved using Monte Carlo methods. These codes and methods have been validated by the analysis of various critical assemblies and calculational benchmarks. Reactor core design procedure at IGCAR consists of: two and three dimensional diffusion theory calculations (codes ALCIALMI and 3DB); auxiliary calculations, (neutron balance, power distributions, etc. are done by codes that are developed in-house); transport theory corrections from two dimensional transport calculations (DOT); irregular geometry treated by Monte Carlo method (KENO); cross section data library used CV2M (25 group)

  10. Social network analysis in identifying influential webloggers: A preliminary study

    Science.gov (United States)

    Hasmuni, Noraini; Sulaiman, Nor Intan Saniah; Zaibidi, Nerda Zura

    2014-12-01

    In recent years, second generation of internet-based services such as weblog has become an effective communication tool to publish information on the Web. Weblogs have unique characteristics that deserve users' attention. Some of webloggers have seen weblogs as appropriate medium to initiate and expand business. These webloggers or also known as direct profit-oriented webloggers (DPOWs) communicate and share knowledge with each other through social interaction. However, survivability is the main issue among DPOW. Frequent communication with influential webloggers is one of the way to keep survive as DPOW. This paper aims to understand the network structure and identify influential webloggers within the network. Proper understanding of the network structure can assist us in knowing how the information is exchanged among members and enhance survivability among DPOW. 30 DPOW were involved in this study. Degree centrality and betweenness centrality measurement in Social Network Analysis (SNA) were used to examine the strength relation and identify influential webloggers within the network. Thus, webloggers with the highest value of these measurements are considered as the most influential webloggers in the network.

  11. Preliminary results of standard quantitative analysis by ED-XRF

    International Nuclear Information System (INIS)

    Lara, Alessandro L. de; Franca, Alana C.; Neto, Manoel R.M.; Paschuk, Sergei A.

    2013-01-01

    A comparison between the results of elemental concentration proposed by XRS-FP software , using data obtained by EDXRF technique with those obtained by stoichiometric calculation was performed. For this purpose, five standard samples of known compounds were produced: two lead- oxide, magnesium chloride and iodine in controlled amounts. The compounds were subsequently mixed and compressed to form tablets. The samples were irradiated in three endpoints, according to an orientation. The measurements were performed at the Laboratory for Radiological UTFPR using X-123SDD the Amptek detector and X-ray tube with silver target from the same manufacturer. The operating conditions tube were 05μA current to a 40 kV voltage. Finally, the 15 spectra analyzed with the software to determine the concentration of chlorine, iodine and lead. Data from this analysis were compared with results expected in stoichiometric calculations. The data provided by the program, a convergence of results, indicating homogeneity of the samples was found. Compared to the stoichiometric calculation, a considerable discrepancy that may be the result of a misconfiguration or contamination of the sample was found. At the end, we created a proposal for continuation of the work using an auxiliary calculation should be developed in the next step

  12. Preliminary analysis of space mission applications for electromagnetic launchers

    Science.gov (United States)

    Miller, L. A.; Rice, E. E.; Earhart, R. W.; Conlon, R. J.

    1984-01-01

    The technical and economic feasibility of using electromagnetically launched EML payloads propelled from the Earth's surface to LEO, GEO, lunar orbit, or to interplanetary space was assessed. Analyses of the designs of rail accelerators and coaxial magnetic accelerators show that each is capable of launching to space payloads of 800 KG or more. A hybrid launcher in which EML is used for the first 2 KM/sec followed by chemical rocket stages was also tested. A cost estimates study shows that one to two EML launches per day are needed to break even, compared to a four-stage rocket. Development models are discussed for: (1) Earth orbital missions; (2) lunar base supply mission; (3) solar system escape mission; (4) Earth escape missions; (5) suborbital missions; (6) electromagnetic boost missions; and (7) space-based missions. Safety factors, environmental impacts, and EML systems analysis are discussed. Alternate systems examined include electrothermal thrustors, an EML rocket gun; an EML theta gun, and Soviet electromagnetic accelerators.

  13. A simplified procedure of linear regression in a preliminary analysis

    Directory of Open Access Journals (Sweden)

    Silvia Facchinetti

    2013-05-01

    Full Text Available The analysis of a statistical large data-set can be led by the study of a particularly interesting variable Y – regressed – and an explicative variable X, chosen among the remained variables, conjointly observed. The study gives a simplified procedure to obtain the functional link of the variables y=y(x by a partition of the data-set into m subsets, in which the observations are synthesized by location indices (mean or median of X and Y. Polynomial models for y(x of order r are considered to verify the characteristics of the given procedure, in particular we assume r= 1 and 2. The distributions of the parameter estimators are obtained by simulation, when the fitting is done for m= r + 1. Comparisons of the results, in terms of distribution and efficiency, are made with the results obtained by the ordinary least square methods. The study also gives some considerations on the consistency of the estimated parameters obtained by the given procedure.

  14. Preliminary Analysis of Slope Stability in Kuok and Surrounding Areas

    Directory of Open Access Journals (Sweden)

    Dewandra Bagus Eka Putra

    2016-12-01

    Full Text Available The level of slope influenced by the condition of the rocks beneath the surface. On high level of slopes, amount of surface runoff and water transport energy is also enlarged. This caused by greater gravity, in line with the surface tilt from the horizontal plane. In other words, topsoil eroded more and more. When the slope becomes twice as steep, then the amount of erosion per unit area be 2.0 - 2.5 times more. Kuok and surrounding area is the road access between the West Sumatra and Riau which plays an important role economies of both provinces. The purpose of this study is to map the locations that have fairly steep slopes and potential mode of landslides. Based on SRTM data obtained,  the roads in Kuok area has a minimum elevation of + 33 m and a maximum  + 217.329 m. Rugged road conditions with slope ranging from 24.08 ° to 44.68 ° causing this area having frequent landslides. The result of slope stability analysis in a slope near the Water Power Plant Koto Panjang, indicated that mode of active failure is toppling failure or rock fall and the potential zone of failure is in the center part of the slope.

  15. Electrical field of electrical appliances versus distance: A preliminary analysis

    International Nuclear Information System (INIS)

    Mustafa, Nur Badariah Ahmad; Nordin, Farah Hani; Ismail, Fakaruddin Ali Ahmad; Alkahtani, Ammar Ahmed; Balasubramaniam, Nagaletchumi; Hock, Goh Chin; Shariff, Z A M

    2013-01-01

    Every household electrical appliance that is plugged in emits electric field even if it is not operating. The source where the appliance is plugged into and the components of household electrical appliance contribute to electric field emission. The electric field may cause unknown disturbance to the environment or also affect the human health and the effect might depends on the strength of the electric field emitted by the appliance. This paper will investigate the strength of the electric field emitted by four different electrical appliances using spectrum analyser. The strength will be captured at three different distances; (i) 1m (ii) 2m and (iii) 3m and analysis of the strength of the electrical field is done based on the three different distances. The measurement results show that the strength of the electric field is strongest when it is captured at 1m and the weakest at 3m from the electrical appliance. The results proved that the farther an object is located from the electrical appliance; the less effect the magnetic field has.

  16. Gas cooled fast reactor 2400 MWTh, status on the conceptual design studies and preliminary safety analysis

    International Nuclear Information System (INIS)

    Malo, J.Y.; Alpy, N.; Bentivoglio, F.

    2009-01-01

    The Gas cooled Fast Reactor (GFR) is considered by the French Commissariat a l'Energie Atomique as a promising concept, combining the benefits of fast spectrum and high temperature, using Helium as coolant. A status on the GFR preliminary viability was made at the end of 2007, ending the pre-conceptual design phase. A consistent overall systems arrangement was proposed and a preliminary safety analysis based on operating transient calculations and a simplified PSA had established a global confidence in the feasibility and safety of this baseline concept. Its potential for attractive performances had been pointed out. Compare to the more mature Sodium Fast Reactor technology, no demonstrator has ever been built and the feasibility demonstration will required a longer lead time. The next main project milestone is related to the GFR viability, scheduled in 2012. The current studies consist in revisiting the reactor reference design options as selected at the end of 2007. Most of them are being consolidated by going more in depth in the analysis. Some possible alternatives are assessed. The paper will give a status on the last studies performed on the core design and corresponding neutronics and cycle performance, the Decay Heat Removal strategy and preliminary safety analysis, systems design and balance of plant... This paper is complementary to the Icapp'09 papers 9062 dealing with the Gas cooled Fast Reactor Demonstrator ALLEGRO and 9378 related to GFR transients analysis. (author)

  17. Conceptual thermal design and analysis of a far-infrared/mid-infrared remote sensing instrument

    Science.gov (United States)

    Roettker, William A.

    1992-07-01

    This paper presents the conceptual thermal design and analysis results for the Spectroscopy of the Atmosphere using Far-Infrared Emission (SAFIRE) instrument. SAFIRE has been proposed for Mission to Planet Earth to study ozone chemistry in the middle atmosphere using remote sensing of the atmosphere in the far-infrared (21-87 microns) and mid-infrared (9-16 microns) spectra. SAFIRE requires that far-IR detectors be cooled to 3-4 K and mid-IR detectors to 80 K for the expected mission lifetime of five years. A superfluid helium dewar and Stirling-cycle cryocoolers provide the cryogenic temperatures required by the infrared detectors. The proposed instrument thermal design uses passive thermal control techniques to reject 465 watts of waste heat from the instrument.

  18. Portable generator-based X RF instrument for non-destructive analysis at crime scenes

    International Nuclear Information System (INIS)

    Schweitzer, Jeffrey S.; Trombka, Jacob I.; Floyd, Samuel; Selavka, Carl; Zeosky, Gerald; Gahn, Norman; McClanahan, Timothy; Burbine, Thomas

    2005-01-01

    Unattended and remote detection systems find applications in space exploration, telemedicine, teleforensics, homeland security and nuclear non-proliferation programs. The National Institute of Justice (NIJ) and the National Aeronautics and Space Administration's (NASA) Goddard Space Flight Center (GSFC) have teamed up to explore the use of NASA developed technologies to help criminal justice agencies and professionals investigate crimes. The objective of the program is to produce instruments and communication networks that have application within both NASA's space program and NIJ, together with state and local forensic laboratories. A general-purpose X-ray fluorescence system has been built for non-destructive analyses of trace and invisible material at crime scenes. This portable instrument is based on a generator that can operate to 60 kV and a Schottky CdTe detector. The instrument has been shown to be successful for the analysis of gunshot residue and a number of bodily fluids at crime scenes

  19. Clinical registry for rheumatoid arthritis; a preliminary analysis

    International Nuclear Information System (INIS)

    Fakhr, A.; Hakim, F.; Zaidi, S.K.; Sharif, A.

    2017-01-01

    To establish a clinical registry for Rheumatoid Arthritis and delineate the most common symptoms that rheumatoid arthritis (RA) patients experience in our set up. Study Design: Cross sectional study. Place and Duration of Study: Study was carried out at Military Hospital (MH) Rawalpindi at Rheumatology Department during the period of Jan 2013 to Jun 2015. Material and Methods: A clinical registry for Rheumatoid Arthritis was developed as per criteria jointly developed by American College of Rheumatology (ACR) along with European League against Rheumatism (EULAR) (2010). Fifty-eight patients were registered after their informed consent and approval by Military Hospital (MH) Rawalpindi ethical committee. Age, gender and relevant clinical parameters of RA patients were recorded on case report forms and stored for analysis in the RA registry in Excel 2010. The figures were reported in frequencies and percentages. Results: Multiple joint pains (48.28%), fever (24.14%), morning stiffness of joints (22.41%) were the most common symptoms in RA patients. Other clinical manifestations included painful bilateral swollen joints (13.79%), pain in different parts of the body (10.34%), Raynaud's phenomenon (10.34%), malaise (8.62%), swollen body parts (8.62%), ulcers (8.62%), fatigue (6.90%), nodules on skin/elbow/interphalangeal joints (6.90%), deformities of fingers/ hand (3.45%), redness of eyes (3.45%), body rash (3.45%), inability to walk (3.45%), cervical lymphadenopathy (1.72%), stiffness of spine (1.72%) and myalgias (1.72%). Conclusion: It is concluded that multiple joint pains, fever and morning stiffness of joints are the most common symptoms of RA patients. (author)

  20. Advanced analysis of finger-tapping performance: a preliminary study.

    Science.gov (United States)

    Barut, Cağatay; Kızıltan, Erhan; Gelir, Ethem; Köktürk, Fürüzan

    2013-06-01

    The finger-tapping test is a commonly employed quantitative assessment tool used to measure motor performance in the upper extremities. This task is a complex motion that is affected by external stimuli, mood and health status. The complexity of this task is difficult to explain with a single average intertap-interval value (time difference between successive tappings) which only provides general information and neglects the temporal effects of the aforementioned factors. This study evaluated the time course of average intertap-interval values and the patterns of variation in both the right and left hands of right-handed subjects using a computer-based finger-tapping system. Cross sectional study. Thirty eight male individuals aged between 20 and 28 years (Mean±SD = 22.24±1.65) participated in the study. Participants were asked to perform single-finger-tapping test for 10 seconds of test period. Only the results of right-handed (RH) 35 participants were considered in this study. The test records the time of tapping and saves data as the time difference between successive tappings for further analysis. The average number of tappings and the temporal fluctuation patterns of the intertap-intervals were calculated and compared. The variations in the intertap-interval were evaluated with the best curve fit method. An average tapping speed or tapping rate can reliably be defined for a single-finger tapping test by analysing the graphically presented data of the number of tappings within the test period. However, a different presentation of the same data, namely the intertap-interval values, shows temporal variation as the number of tapping increases. Curve fitting applications indicate that the variation has a biphasic nature. The measures obtained in this study reflect the complex nature of the finger-tapping task and are suggested to provide reliable information regarding hand performance. Moreover, the equation reflects both the variations in and the general

  1. Diisocyanate emission from a paint product: a preliminary analysis.

    Science.gov (United States)

    Jarand, Curtis W; Akapo, Samuel O; Swenson, Lonie J; Kelman, Bruce J

    2002-07-01

    Exposure of workers to diisocyanates in the polyurethane foam manufacturing industry is well documented. However, very little quantitative data have been published on exposure to diisocyanates from the use of paints and coatings. The purpose of this study was to evaluate emission of 2,4-toluene diisocyanate, 2,6-toluene diisocyanate (2,6-TDI), and isophorone diisocyanate from a commercially available two-stage concrete coating and sealant. A laboratory model of an outdoor deck coating process was developed and diisocyanate concentrations determined by derivatization with 1-(2-methoxyphenol)-piperazine and subsequent high performance liquid chromatographic analysis with UV detection. The detection limit for 2,4-toluene diisocyanate and 2,6-toluene diisocyanate urea derivatives was 0.6 microg TDI/gm wet product, and 0.54 microg IPDI/gm wet product for the isophorone diisocyanate urea derivative. No 2,4-toluene diisocyanate or isophorone diisocyanate was detected in the mixed product. A maximum mean 2,6-TDI emission rate of 0.32 microg of 2,6-TDI/gram of wet product applied/hour was observed for the 1-hour sampling time, 0.38 microg of 2,6-TDI/gram of wet product applied/hour was observed for the 5-hour sampling time, and 0.02 micrpg of 2,6-TDI/gram of wet product applied/hour was observed for the 15-hour sampling time. The decrease in rate of 2,6-TDI emission over the 15-hour period indicates that emission of 2,6-TDI is virtually complete after 5 hours. These emission rates should allow industrial hygienists to calculate exposures to isocyanates emitted from at least one curing sealant.

  2. Cognitive Task Analysis of Business Jet Pilots' Weather Flying Behaviors: Preliminary Results

    Science.gov (United States)

    Latorella, Kara; Pliske, Rebecca; Hutton, Robert; Chrenka, Jason

    2001-01-01

    This report presents preliminary findings from a cognitive task analysis (CTA) of business aviation piloting. Results describe challenging weather-related aviation decisions and the information and cues used to support these decisions. Further, these results demonstrate the role of expertise in business aviation decision-making in weather flying, and how weather information is acquired and assessed for reliability. The challenging weather scenarios and novice errors identified in the results provide the basis for experimental scenarios and dependent measures to be used in future flight simulation evaluations of candidate aviation weather information systems. Finally, we analyzed these preliminary results to recommend design and training interventions to improve business aviation decision-making with weather information. The primary objective of this report is to present these preliminary findings and to document the extended CTA methodology used to elicit and represent expert business aviator decision-making with weather information. These preliminary findings will be augmented with results from additional subjects using this methodology. A summary of the complete results, absent the detailed treatment of methodology provided in this report, will be documented in a separate publication.

  3. Astrobiology Sample Analysis Program (ASAP) for Advanced Life Detection Instrumentation Development and Calibration

    Science.gov (United States)

    Glavin, Daniel; Brinkerhoff, Will; Dworkin, Jason; Eigenbrode, Jennifer; Franz, Heather; Mahaffy, Paul; Stern, Jen; Blake, Daid; Sandford, Scott; Fries, marc; hide

    2008-01-01

    Scientific ground-truth measurements for near-term Mars missions, such as the 2009 Mars Science Laboratory (MSL) mission, are essential for validating current in situ flight instrumentation and for the development of advanced instrumentation technologies for life-detection missions over the next decade. The NASA Astrobiology Institute (NAI) has recently funded a consortium of researchers called the Astrobiology Sample Analysis Program (ASAP) to analyze an identical set of homogenized martian analog materials in a "round-robin" style using both state-of-the-art laboratory techniques as well as in-situ flight instrumentation including the SAM gas chromatograph mass spectrometer and CHEMIN X-ray diffraction/fluorescence instruments on MSL and the Urey and MOMA organic analyzer instruments under development for the 2013 ExoMars missions. The analog samples studied included an Atacama Desert soil from Chile, the Murchison meteorite, a gypsum sample from the 2007 AMASE Mars analog site, jarosite from Panoche Valley, CA, a hydrothermal sample from Rio Tinto, Spain, and a "blind" sample collected during the 2007 MSL slow-motion field test in New Mexico. Each sample was distributed to the team for analysis to: (1) determine the nature and inventory of organic compounds, (2) measure the bulk carbon and nitrogen isotopic composition, (3) investigate elemental abundances, mineralogy and matrix, and (4) search for biological activity. The experimental results obtained from the ASAP Mars analog research consortium will be used to build a framework for understanding the biogeochemistry of martian analogs, help calibrate current spaceflight instrumentation, and enhance the scientific return from upcoming missions.

  4. Crystallization and preliminary X-ray diffraction analysis of rat autotaxin

    International Nuclear Information System (INIS)

    Day, Jacqueline E.; Hall, Troii; Pegg, Lyle E.; Benson, Timothy E.; Hausmann, Jens; Kamtekar, Satwik

    2010-01-01

    Autotaxin (ATX), a pyrophosphatase/phosphodiesterase enzyme, is a promising drug target for many indications and is only distantly related to enzymes of previously determined structure. Here, the cloning, expression, purification, crystallization and preliminary diffraction analysis of ATX are reported. Rat autotaxin has been cloned, expressed, purified to homogeneity and crystallized via hanging-drop vapour diffusion using PEG 3350 as precipitant and ammonium iodide and sodium thiocyanate as salts. The crystals diffracted to a maximum resolution of 2.05 Å and belonged to space group P1, with unit-cell parameters a = 53.8, b = 63.3, c = 70.5 Å, α = 98.8, β = 106.2, γ = 99.8°. Preliminary X-ray diffraction analysis indicated the presence of one molecule per asymmetric unit, with a solvent content of 47%

  5. Relative risk analysis in regulating the use of radiation-emitting medical devices. A preliminary application

    Energy Technology Data Exchange (ETDEWEB)

    Jones, E.D.; Banks, W.W.; Altenbach, T.J.; Fischer, L.E. [Lawrence Livermore National Lab., CA (United States)

    1995-09-01

    This report describes a preliminary application of an analysis approach for assessing relative risks in the use of radiation- emitting medical devices. Results are presented on human-initiated actions and failure modes that are most likely to occur in the use of the Gamma Knife, a gamma irradiation therapy device. This effort represents an initial step in a US Nuclear Regulatory Commission (NRC) plan to evaluate the potential role of risk analysis in regulating the use of nuclear medical devices. For this preliminary application of risk assessment, the focus was to develop a basic process using existing techniques for identifying the most likely risk contributors and their relative importance. The approach taken developed relative risk rankings and profiles that incorporated the type and quality of data available and could present results in an easily understood form. This work was performed by the Lawrence Livermore National Laboratory for the NRC.

  6. Crystallization and preliminary X-ray diffraction analysis of West Nile virus

    International Nuclear Information System (INIS)

    Kaufmann, Bärbel; Plevka, Pavel; Kuhn, Richard J.; Rossmann, Michael G.

    2010-01-01

    Crystals of infectious West Nile virus were obtained and diffracted at best to about 25 Å resolution. Preliminary analysis of the diffraction pattern suggested tight hexagonal packing of the intact virus. West Nile virus, a human pathogen, is closely related to other medically important flaviviruses of global impact such as dengue virus. The infectious virus was purified from cell culture using polyethylene glycol (PEG) precipitation and density-gradient centrifugation. Thin amorphously shaped crystals of the lipid-enveloped virus were grown in quartz capillaries equilibrated by vapor diffusion. Crystal diffraction extended at best to a resolution of about 25 Å using synchrotron radiation. A preliminary analysis of the diffraction images indicated that the crystals had unit-cell parameters a ≃ b ≃ 480 Å, γ = 120°, suggesting a tight hexagonal packing of one virus particle per unit cell

  7. Preliminary Dynamic Feasibility and Analysis of a Spherical, Wind-Driven (Tumbleweed), Martian Rover

    Science.gov (United States)

    Flick, John J.; Toniolo, Matthew D.

    2005-01-01

    The process and findings are presented from a preliminary feasibility study examining the dynamics characteristics of a spherical wind-driven (or Tumbleweed) rover, which is intended for exploration of the Martian surface. The results of an initial feasibility study involving several worst-case mobility situations that a Tumbleweed rover might encounter on the surface of Mars are discussed. Additional topics include the evaluation of several commercially available analysis software packages that were examined as possible platforms for the development of a Monte Carlo Tumbleweed mission simulation tool. This evaluation lead to the development of the Mars Tumbleweed Monte Carlo Simulator (or Tumbleweed Simulator) using the Vortex physics software package from CM-Labs, Inc. Discussions regarding the development and evaluation of the Tumbleweed Simulator, as well as the results of a preliminary analysis using the tool are also presented. Finally, a brief conclusions section is presented.

  8. Preliminary X-ray analysis of twinned crystals of sarcosine dimethylglycine methyltransferase from Halorhodospira halochoris

    International Nuclear Information System (INIS)

    Kallio, Juha Pekka; Jänis, Janne; Nyyssölä, Antti; Hakulinen, Nina; Rouvinen, Juha

    2009-01-01

    The crystallization and preliminary X-ray diffraction analysis of sarcosine dimethylglycine methyltransferase from H. halochoris is reported. Sarcosine dimethylglycine methyltransferase (EC 2.1.1.157) is an enzyme from the extremely halophilic anaerobic bacterium Halorhodospira halochoris. This enzyme catalyzes the twofold methylation of sarcosine to betaine, with S-adenosylmethionine (AdoMet) as the methyl-group donor. This study presents the crystallization and preliminary X-ray analysis of recombinant sarcosine dimethylglycine methyltransferase produced in Escherichia coli. Mass spectroscopy was used to determine the purity and homogeneity of the enzyme material. Two different crystal forms, which initially appeared to be hexagonal and tetragonal, were obtained. However, on analyzing the diffraction data it was discovered that both crystal forms were pseudo-merohedrally twinned. The true crystal systems were monoclinic and orthorhombic. The monoclinic crystal diffracted to a maximum of 2.15 Å resolution and the orthorhombic crystal diffracted to 1.8 Å resolution

  9. Preliminary Disposal Analysis for Selected Accelerator Production of Tritium Waste Streams

    International Nuclear Information System (INIS)

    Ades, M.J.; England, J.L.

    1998-06-01

    A preliminary analysis was performed for two selected Accelerator Production of Tritium (APT) generated mixed and low-level waste streams to determine if one mixed low-level waste (MLLW) stream that includes the Mixed Waste Lead (MWL) can be disposed of at the Nevada Test Site (NTS) and at the Hanford Site and if one low-level radioactive waste (LLW) stream, that includes the Tungsten waste stream (TWS) generated by the Tungsten Neutron Source modules and used in the Target/Blanket cavity vessel, can be disposed of in the LLW Vaults at the Savannah River Plant (SRP). The preliminary disposal analysis that the radionuclide concentrations of the two selected APT waste streams are not in full compliance with the Waste Acceptance Criteria (WAC) and the Performance Assessment (PA) radionuclide limits of the disposal sites considered

  10. Relative risk analysis in regulating the use of radiation-emitting medical devices. A preliminary application

    International Nuclear Information System (INIS)

    Jones, E.D.; Banks, W.W.; Altenbach, T.J.; Fischer, L.E.

    1995-09-01

    This report describes a preliminary application of an analysis approach for assessing relative risks in the use of radiation- emitting medical devices. Results are presented on human-initiated actions and failure modes that are most likely to occur in the use of the Gamma Knife, a gamma irradiation therapy device. This effort represents an initial step in a US Nuclear Regulatory Commission (NRC) plan to evaluate the potential role of risk analysis in regulating the use of nuclear medical devices. For this preliminary application of risk assessment, the focus was to develop a basic process using existing techniques for identifying the most likely risk contributors and their relative importance. The approach taken developed relative risk rankings and profiles that incorporated the type and quality of data available and could present results in an easily understood form. This work was performed by the Lawrence Livermore National Laboratory for the NRC

  11. National Data Center Preparedness Exercise 2015 (NPE 2015): MY-NDC Preliminary Analysis Result

    International Nuclear Information System (INIS)

    Faisal Izwan Abdul Rashid; Muhammed Zulfakar Zolkaffly

    2016-01-01

    Malaysia has established the CTBT National Data Centre (MY-NDC) in December 2005. MY-NDC is tasked to perform Comprehensive Nuclear-Test-Ban-Treaty (CTBT) data management as well as provide information for Treaty related events to Nuclear Malaysia as CTBT National Authority. In 2015, MY-NDC has participated in the National Data Centre Preparedness Exercise 2015 (NPE 2015). This paper aims at presenting MY-NDC preliminary analysis result of NPE 2015. In NPE 2015, MY-NDC has performed five different analyses, namely, radionuclide, atmospheric transport modelling (ATM), data fusion, seismic analysis and site forensics. The preliminary findings show the hypothetical scenario in NPE 2015 most probably is an uncontained event resulted high release of radionuclide to the air. (author)

  12. Preliminary safety analysis of the HTTR-IS nuclear hydrogen production system

    International Nuclear Information System (INIS)

    Sato, Hiroyuki; Ohashi, Hirofumi; Tazawa, Yujiro; Tachibana, Yukio; Sakaba, Nariaki

    2010-06-01

    Japan Atomic Energy Agency is planning to demonstrate hydrogen production by thermochemical water-splitting IS process utilizing heat from the high-temperature gas-cooled reactor HTTR (HTTR-IS system). The previous study identified that the HTTR modification due to the coupling of hydrogen production plant requires an additional safety review since the scenario and quantitative values of the evaluation items would be altered from the original HTTR safety review. Hence, preliminary safety analyses are conducted by using the system analysis code. Calculation results showed that evaluation items such as a coolant pressure, temperatures of heat transfer tubes at the pressure boundary, etc., did not exceed allowable values. Also, the peak fuel temperature did not exceed allowable value and therefore the reactor core was not damaged and cooled sufficiently. This report compiles calculation conditions, event scenarios and the calculation results of the preliminary safety analysis. (author)

  13. Preliminary Hazards Analysis of K-Basin Fuel Encapsulation and Storage

    International Nuclear Information System (INIS)

    Strickland, G.C.

    1994-01-01

    This Preliminary Hazards Analysis (PHA) systematically examines the K-Basin facilities and their supporting systems for hazards created by abnormal operating conditions and external events (e.g., earthquakes) which have the potential for causing undesirable consequences to the facility worker, the onsite individual, or the public. The operational activities examined are fuel encapsulation, fuel storage and cooling. Encapsulation of sludges in the basins is not examined. A team of individuals from Westinghouse produced a set of Hazards and Operability (HAZOP) tables documenting their examination of abnormal process conditions in the systems and activities examined in K-Basins. The purpose of this report is to reevaluate and update the HAZOP in the original Preliminary Hazard Analysis of K-Basin Fuel Encapsulation and Storage originally developed in 1991

  14. Elemental analysis of granite by instrumental neutron activation analysis (INAA) and X-ray fluorescence analysis (XRF)

    International Nuclear Information System (INIS)

    El-Taher, A.

    2012-01-01

    The instrumental neutron activation analysis technique (INAA) was used for qualitative and quantitative analysis of granite samples collected from four locations in the Aswan area in South Egypt. The samples were prepared together with their standards and simultaneously irradiated in a neutron flux of 7×10 11 n/cm 2 s in the TRIGA Mainz research reactor. Gamma-ray spectra from an hyper-pure germanium detector were analyzed. The present study provides the basic data of elemental concentrations of granite rocks. The following elements have been determined Na, Mg, K, Fe, Mn, Sc, Cr, Ti, Co, Zn, Ga, Rb, Zr, Nb, Sn, Ba, Cs, La, Ce, Nd, Sm, Eu, Yb, Lu, Hf, Ta, Th and U. The X-ray fluorescence (XRF) was used for comparison and to detect elements, which can be detected only by XRF such as F, S, Cl, Co, Cu, Mo, Ni, Pb, Se and V. The data presented here are our contribution to understanding the elemental composition of the granite rocks. Because there are no existing databases for the elemental analysis of granite, our results are a start to establishing a database for the Egyptian granite. It is hoped that the data presented here will be useful to those dealing with geochemistry, granite chemistry and related fields. - Highlights: ► Instrumental neutron activation analysis technique (INAA) was used for qualitative and quantitative analysis of granite. ► The samples were prepared together with their standards and simultaneously irradiated in a neutron flux of 7×10 11 n/cm 2 s in the TRIGA Mainz research reactor. ► Following elements have been determined Na, Mg, K, Fe, Mn, Sc, Cr, Ti, Co, Zn, Ga, Rb, Zr, Nb, Sn, Ba, Cs, La, Ce, Nd, Sm, Eu, Yb, Lu, Hf, Ta, Th and U.

  15. Preliminary spatial analysis of combined BATSE/Ulysses gamma-ray burst locations

    International Nuclear Information System (INIS)

    Kippen, R. Marc; Hurley, Kevin; Pendleton, Geoffrey N.

    1998-01-01

    We present the preliminary spatial analysis of 278 bursts that have been localized by BATSE and the two-spacecraft Compton/Ulysses Interplanetary Network. The large number and superior accuracy of the combined BATSE/Ulysses locations provides improved sensitivity to small-angle source properties. We find that the locations are consistent with large- and small-scale isotropy, with no significant small-angle clustering. We constrain the fraction of sources in clusters and discuss the implications for burst repetition

  16. Sludge Treatment Project Engineered Container Retrieval And Transfer System Preliminary Design Hazard Analysis Supplement 1

    International Nuclear Information System (INIS)

    Franz, G.R.; Meichle, R.H.

    2011-01-01

    This 'What/If' Hazards Analysis addresses hazards affecting the Sludge Treatment Project Engineered Container Retrieval and Transfer System (ECRTS) NPH and external events at the preliminary design stage. In addition, the hazards of the operation sequence steps for the mechanical handling operations in preparation of Sludge Transport and Storage Container (STSC), disconnect STSC and prepare STSC and Sludge Transport System (STS) for shipping are addressed.

  17. Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module

    Energy Technology Data Exchange (ETDEWEB)

    Lee C. Cadwallader

    2010-06-01

    This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a small tritium-breeding test blanket module design for the International Thermonuclear Experimental Reactor. The FMEA was quantified with “generic” component failure rate data, and the failure events are binned into postulated initiating event families and frequency categories for safety assessment. An appendix to this report contains repair time data to support an occupational radiation exposure assessment for test blanket module maintenance.

  18. Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module

    Energy Technology Data Exchange (ETDEWEB)

    Lee C. Cadwallader

    2007-08-01

    This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a small tritium-breeding test blanket module design for the International Thermonuclear Experimental Reactor. The FMEA was quantified with “generic” component failure rate data, and the failure events are binned into postulated initiating event families and frequency categories for safety assessment. An appendix to this report contains repair time data to support an occupational radiation exposure assessment for test blanket module maintenance.

  19. Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module

    International Nuclear Information System (INIS)

    Lee C. Cadwallader

    2007-01-01

    This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a small tritium-breeding test blanket module design for the International Thermonuclear Experimental Reactor. The FMEA was quantified with 'generic' component failure rate data, and the failure events are binned into postulated initiating event families and frequency categories for safety assessment. An appendix to this report contains repair time data to support an occupational radiation exposure assessment for test blanket module maintenance

  20. PANDA-A novel instrument for non-destructive sample analysis

    International Nuclear Information System (INIS)

    Turunen, Jani; Peraejaervi, Kari; Poellaenen, Roy; Toivonen, Harri

    2010-01-01

    An instrument known as PANDA (Particles And Non-Destructive Analysis) for non-destructive sample analysis has been designed and built at the Finnish Radiation and Nuclear Safety Authority (STUK). In PANDA the measurement techniques and instruments designed for the basic research are applied to the analysis of environmental samples. PANDA has two vacuum chambers, one for loading samples and the other for measurements. In the measurement chamber there are two individual measurement positions. Currently the first one hosts an HPGe gamma detector and a position-sensitive alpha detector. The second measurement position is intended for precise characterization of found particles. PANDA's data are recorded in event mode and events are timestamped. In the present article the technical design of PANDA is presented in detail. In addition, its performance using depleted uranium particles and an air filter is demonstrated.

  1. Study on the mercury evolution in a laboratory multi specific aquatic system by using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Bubach, Debora; Guevara, Sergio Ribeiro; Arribere, Maria A.; Pechen de d'Angelo, Ana; Ferrari, Ana; Venturino, Andres

    1999-01-01

    A preliminary study on the evolution of mercury in the organisms of a laboratory multi specific aquatic system was performed using Instrumental Neutron Activation Analysis (INAA). Some of the possible effects of mercury toxicity were monitored by analyzing early biochemical indicators. The system consisted of an aquarium with bed sediments, aquatic macrophytes (Myriophyllum sp.), bivalves (Diplodom sp.) and exotic fish, simulating a long term contamination situation of unknown causes, where the sediments are the contaminant reservoir. Samples of the abiotic components of the system were analyzed at the beginning of the experiment, and again when the organisms were sampled. Fish carcass, kidney and liver samples, bivalve hepatopancreas, and whole macrophytes were extracted ana analyzed for mercury and other elements by INAA at the beginning of the experiment, and after 48 and 96 hours. Since some crustal elements such as Sc and La were detected in the hepatopancreas and macrophyte samples, enrichment factors for mercury, with respect to the <63 μm sediment fraction, were computed to discriminate the metabolized Hg content from that associated to the particulate. The hepatopancreas index, some indicators of oxidative stress (γ-Glutamyl-cysteinyl-glycine content and lipid peroxidation) and brain acetilcolinesterasa were measured as early indicators of toxicity. (author)

  2. Preliminary crystallographic analysis of a possible transcription factor encoded by the mimivirus L544 gene

    International Nuclear Information System (INIS)

    Ciaccafava, Alexandre; Lartigue, Audrey; Mansuelle, Pascal; Jeudy, Sandra; Abergel, Chantal

    2011-01-01

    The mimivirus L544 gene product was expressed in E. coli and crystallized; preliminary phasing of a MAD data set was performed using the selenium signal present in a crystal of recombinant selenomethionine-substituted protein. Mimivirus is the prototype of a new family (the Mimiviridae) of nucleocytoplasmic large DNA viruses (NCLDVs), which already include the Poxviridae, Iridoviridae, Phycodnaviridae and Asfarviridae. Mimivirus specifically replicates in cells from the genus Acanthamoeba. Proteomic analysis of purified mimivirus particles revealed the presence of many subunits of the DNA-directed RNA polymerase II complex. A fully functional pre-transcriptional complex appears to be loaded in the virions, allowing mimivirus to initiate transcription within the host cytoplasm immediately upon infection independently of the host nuclear apparatus. To fully understand this process, a systematic study of mimivirus proteins that are predicted (by bioinformatics) or suspected (by proteomic analysis) to be involved in transcription was initiated by cloning and expressing them in Escherichia coli in order to determine their three-dimensional structures. Here, preliminary crystallographic analysis of the recombinant L544 protein is reported. The crystals belonged to the orthorhombic space group C222 1 with one monomer per asymmetric unit. A MAD data set was used for preliminary phasing using the selenium signal present in a selenomethionine-substituted protein crystal

  3. EVA: laparoscopic instrument tracking based on Endoscopic Video Analysis for psychomotor skills assessment.

    Science.gov (United States)

    Oropesa, Ignacio; Sánchez-González, Patricia; Chmarra, Magdalena K; Lamata, Pablo; Fernández, Alvaro; Sánchez-Margallo, Juan A; Jansen, Frank Willem; Dankelman, Jenny; Sánchez-Margallo, Francisco M; Gómez, Enrique J

    2013-03-01

    The EVA (Endoscopic Video Analysis) tracking system is a new system for extracting motions of laparoscopic instruments based on nonobtrusive video tracking. The feasibility of using EVA in laparoscopic settings has been tested in a box trainer setup. EVA makes use of an algorithm that employs information of the laparoscopic instrument's shaft edges in the image, the instrument's insertion point, and the camera's optical center to track the three-dimensional position of the instrument tip. A validation study of EVA comprised a comparison of the measurements achieved with EVA and the TrEndo tracking system. To this end, 42 participants (16 novices, 22 residents, and 4 experts) were asked to perform a peg transfer task in a box trainer. Ten motion-based metrics were used to assess their performance. Construct validation of the EVA has been obtained for seven motion-based metrics. Concurrent validation revealed that there is a strong correlation between the results obtained by EVA and the TrEndo for metrics, such as path length (ρ = 0.97), average speed (ρ = 0.94), or economy of volume (ρ = 0.85), proving the viability of EVA. EVA has been successfully validated in a box trainer setup, showing the potential of endoscopic video analysis to assess laparoscopic psychomotor skills. The results encourage further implementation of video tracking in training setups and image-guided surgery.

  4. Development Instruments Through Confirmatory Factor Analysis (CFA in Appropriate Intensity Assessment

    Directory of Open Access Journals (Sweden)

    Ari Saptono

    2017-06-01

    Full Text Available The research aims to develop the valid and reliable measurement instruments of entrepreneurship intention in vocational secondary school students. Multi stage random sampling was used as the technique to determine sample (300 respondents. The research method used research and development with confirmatory factor analysis (CFA. Result of confirmatory factor analysis (CFA at the second order with robust maximum likelihood method shows that valid and reliable instrument with the acquisition value of loading factor is more than 0.5 (> 0,5 and a significance value of t is more than 1,96 (> 1,96. Reliability test results shows that the value of the combined construct reliability (CR of 0.97and a variance value extract (VE to 0.52 is greater than the limit of acceptance CR ≥ 0.70 and VE ≥ 0.50. The conclusion of the measurement instruments of entrepreneurship intention with three dimensions and 31 items met the standards of validity and reliability in accordance with the instrument development process.

  5. Instruments for the promotion of environmental innovations. Stocktaking, evaluation and deficit analysis; Instrumente zur Foerderung von Umweltinnovationen. Bestandsaufnahme, Bewertung und Defizitanalyse

    Energy Technology Data Exchange (ETDEWEB)

    Rennings, Klaus; Rammer, Christian; Oberndorfer, Ulrich [Zentrum fuer Europaeische Wirtschaftsforschung (ZEW), GmbH, Mannheim (DE)] (and others)

    2008-03-15

    In the ecological report 2006 of the Federal Ministry for the Environment, Nature Conservation and Nuclear Safety (Berlin, Federal Republic of Germany) with the title ''Environment - Innovation - Occupation'', the Federal Ministry outlines the concept of an innovative oriented environmental policy. An innovative environmental policy contributes to the reduction of the environmental pollution and the ecological damages of industrial production. In this background, the question arises, how the environmental policy can support appropriate innovative activities. For this, the research project under consideration presents the following contributions: (a) Overview of the most important instruments for the promotion of environmental innovations in Germany; (b) Estimation of the effectiveness of the instruments including gap analysis and deficit analysis; (c) Presentation of foreign Best Practice Examples (instruments and environmental political beginnings); (d) Proposals for priority environmental political starting points to the advancement of the equipment and pointing out the further research need.

  6. Serum analysis of coronary heart disease patients by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Jong-Hwa Moon; Yong-Sam Chung; Kwang-Won Park; Okhee Lee

    2007-01-01

    Due to changes of the dietary pattern and life style, cardiovascular diseases like coronary heart disease (CHD) have been increasing in Korea. In this study, the levels of the serum minerals such as Na, Cl, K, Ca, Fe, Zn and Se for 75 patients with CHD and 25 normal persons, who were older than the age of 40, were investigated by instrumental neutron activation analysis. For analytical quality control, the reference materials, INSPQ and Seronorm, were analyzed simultaneously. The relative errors of the analytical values for the reference materials were within 10% of the certified values. The average concentrations of Na, Cl, K, Ca, Fe, Zn and Se in the serum of the male patients were 2,850±260 mg/l, 3,400±310 mg/l, 160±30 mg/l, 80.9±11.7 mg/l, 1.57±0.73 mg/l, 0.094±0.019 mg/l and 0.795±0.163 mg/l, respectively. The concentrations of Na, Cl, K, Ca, Fe, Zn and Se in the serum of the female patients were 2,890±240 mg/l, 3,430±350 mg/l, 169±27 mg/l, 81.8±13.0 mg/l, 1.26±0.44 mg/l, 0.099±0.015 mg/l and 0.769±0.105 mg/l, respectively. In a comparison between the patients and the normal group for both genders, while the levels of the elemental concentrations such as Na, Cl, K, Ca, Fe and Se were similar, the Zn concentration level of the CHD patients was significantly lower than that of the normal ones. The present study showed that the Zn concentration in the serum could be associated with CHD in Korean adults. (author)

  7. The contextual effects of social capital on health: a cross-national instrumental variable analysis.

    Science.gov (United States)

    Kim, Daniel; Baum, Christopher F; Ganz, Michael L; Subramanian, S V; Kawachi, Ichiro

    2011-12-01

    Past research on the associations between area-level/contextual social capital and health has produced conflicting evidence. However, interpreting this rapidly growing literature is difficult because estimates using conventional regression are prone to major sources of bias including residual confounding and reverse causation. Instrumental variable (IV) analysis can reduce such bias. Using data on up to 167,344 adults in 64 nations in the European and World Values Surveys and applying IV and ordinary least squares (OLS) regression, we estimated the contextual effects of country-level social trust on individual self-rated health. We further explored whether these associations varied by gender and individual levels of trust. Using OLS regression, we found higher average country-level trust to be associated with better self-rated health in both women and men. Instrumental variable analysis yielded qualitatively similar results, although the estimates were more than double in size in both sexes when country population density and corruption were used as instruments. The estimated health effects of raising the percentage of a country's population that trusts others by 10 percentage points were at least as large as the estimated health effects of an individual developing trust in others. These findings were robust to alternative model specifications and instruments. Conventional regression and to a lesser extent IV analysis suggested that these associations are more salient in women and in women reporting social trust. In a large cross-national study, our findings, including those using instrumental variables, support the presence of beneficial effects of higher country-level trust on self-rated health. Previous findings for contextual social capital using traditional regression may have underestimated the true associations. Given the close linkages between self-rated health and all-cause mortality, the public health gains from raising social capital within and across

  8. Thermal and Alignment Analysis of the Instrument-Level ATLAS Thermal Vacuum Test

    Science.gov (United States)

    Bradshaw, Heather

    2012-01-01

    This paper describes the thermal analysis and test design performed in preparation for the ATLAS thermal vacuum test. NASA's Advanced Topographic Laser Altimeter System (ATLAS) will be flown as the sole instrument aboard the Ice, Cloud, and land Elevation Satellite-2 (ICESat-2). It will be used to take measurements of topography and ice thickness for Arctic and Antarctic regions, providing crucial data used to predict future changes in worldwide sea levels. Due to the precise measurements ATLAS is taking, the laser altimeter has very tight pointing requirements. Therefore, the instrument is very sensitive to temperature-induced thermal distortions. For this reason, it is necessary to perform a Structural, Thermal, Optical Performance (STOP) analysis not only for flight, but also to ensure performance requirements can be operationally met during instrument-level thermal vacuum testing. This paper describes the thermal model created for the chamber setup, which was used to generate inputs for the environmental STOP analysis. This paper also presents the results of the STOP analysis, which indicate that the test predictions adequately replicate the thermal distortions predicted for flight. This is a new application of an existing process, as STOP analyses are generally performed to predict flight behavior only. Another novel aspect of this test is that it presents the opportunity to verify pointing results of a STOP model, which is not generally done. It is possible in this case, however, because the actual pointing will be measured using flight hardware during thermal vacuum testing and can be compared to STOP predictions.

  9. Preliminary CFD Analysis for HVAC System Design of a Containment Building

    Energy Technology Data Exchange (ETDEWEB)

    Son, Sung Man; Choi, Choengryul [ELSOLTEC, Yongin (Korea, Republic of); Choo, Jae Ho; Hong, Moonpyo; Kim, Hyungseok [KEPCO Engineering and Construction, Gimcheon (Korea, Republic of)

    2016-10-15

    HVAC (Heating, Ventilation, Air Conditioning) system has been mainly designed based on overall heat balance and averaging concepts, which is simple and useful for designing overall system. However, such a method has the disadvantage that cannot predict the local flow and temperature distributions in a containment building. In this study, a CFD (Computational Fluid Dynamics) preliminary analysis is carried out to obtain detailed flow and temperature distributions in a containment building and to ensure that such information can be obtained via CFD analysis. This approach can be useful for hydrogen analysis in an accident related to hydrogen released into a containment building. In this study, CFD preliminary analysis has been performed to obtain the detailed information of the reactor containment building by using the CFD analysis techniques and to ensure that such information can be obtained via CFD analysis. We confirmed that CFD analysis can offer enough detailed information about flow patterns and temperature field and that CFD technique is a useful tool for HVAC design of nuclear power plants.

  10. Prevalence Estimation and Validation of New Instruments in Psychiatric Research: An Application of Latent Class Analysis and Sensitivity Analysis

    Science.gov (United States)

    Pence, Brian Wells; Miller, William C.; Gaynes, Bradley N.

    2009-01-01

    Prevalence and validation studies rely on imperfect reference standard (RS) diagnostic instruments that can bias prevalence and test characteristic estimates. The authors illustrate 2 methods to account for RS misclassification. Latent class analysis (LCA) combines information from multiple imperfect measures of an unmeasurable latent condition to…

  11. Comparison of textural atributes of selected meat sausages using instrumental analysis

    Directory of Open Access Journals (Sweden)

    Vladimír Vietoris

    2013-03-01

    Full Text Available Normal 0 21 false false false SK X-NONE X-NONE The aim of the study was to compare textural atributes of selected meat sausages using instrumental analysis. For this purpose, seven different meat sausage samples were treated by instrumental analysis, by the use of Warner-Bratzler probe,  to find differences for two selected textural parameter firmness and work of shear. As expected, various values of mentioned atributes were obtained for different samples tested in fresh stage and after storage under controlled conditions (48 hrs., 30 °C temp., and 60 % R.H. before and after cooking. For statistical evaluation of results, paired T test was used, statistically significant differences were taken at pdoi:10.5219/273

  12. The use of instrumental neutron activation analysis for the determination of arsenic concentrations in poultry

    International Nuclear Information System (INIS)

    Bolton, B.A.; Hopke, Ph.K.

    1975-01-01

    There has been recent public concern over the use of organic arsenicals as medicaments and growth stimulators for poultry. In early studies, there was a correlation shown between the intake of arsenic and carcinogenisis. Several investigators have stronly disputed these results. The purpose of this study was not to verify or discredit this carcinogenic theory but simply to determine if the arsenic levels in poultry could be measured using instrumental activation analysis. These analyses indicate that arsenic concentrations in poultry can be measured at levels below the mandatory maximum levels of arsenic in poultry, in the investigated cases it varied between 0.3 and 0.03 ppm. Nondestructive, instrumental neutron activation analysis with a simple comparative evaluation was used: arsenic concentrations were determined by comparing the sample gamma-ray peak area to the standard peak area. (T.G.)

  13. Coherent diffraction microscopy at SPring-8: instrumentation, data acquisition and data analysis

    International Nuclear Information System (INIS)

    Xu, Rui; Salha, Sara; Raines, Kevin S.; Jiang, Huaidong; Chen, Chien-Chun; Takahashi, Yukio; Kohmura, Yoshiki; Nishino, Yoshinori; Song, Changyong; Ishikawa, Tetsuya; Miao, Jianwei

    2011-01-01

    An instrumentation and data analysis review of coherent diffraction microscopy at SPring-8 is given. This work will be of interest to those who want to apply coherent diffraction imaging to studies of materials science and biological samples. Since the first demonstration of coherent diffraction microscopy in 1999, this lensless imaging technique has been experimentally refined by continued developments. Here, instrumentation and experimental procedures for measuring oversampled diffraction patterns from non-crystalline specimens using an undulator beamline (BL29XUL) at SPring-8 are presented. In addition, detailed post-experimental data analysis is provided that yields high-quality image reconstructions. As the acquisition of high-quality diffraction patterns is at least as important as the phase-retrieval procedure to guarantee successful image reconstructions, this work will be of interest for those who want to apply this imaging technique to materials science and biological samples

  14. Preliminary hazard analysis for the Brayton Isotope Ground Demonstration System (including vacuum test chamber)

    International Nuclear Information System (INIS)

    Miller, L.G.

    1975-01-01

    The Preliminary Hazard Analysis (PHA) of the BIPS-GDS is a tabular summary of hazards and undesired events which may lead to system damage or failure and/or hazard to personnel. The PHA reviews the GDS as it is envisioned to operate in the Vacuum Test Chamber (VTC) of the GDS Test Facility. The VTC and other equipment which will comprise the test facility are presently in an early stage of preliminary design and will undoubtedly undergo numerous changes before the design is frozen. The PHA and the FMECA to follow are intended to aid the design effort by identifying areas of concern which are critical to the safety and reliability of the BIPS-GDS and test facility

  15. Expression, purification, crystallization and preliminary crystallographic analysis of the proliferation-associated protein Ebp1

    International Nuclear Information System (INIS)

    Kowalinski, Eva; Bange, Gert; Wild, Klemens; Sinning, Irmgard

    2007-01-01

    Preliminary X-ray analysis of the proliferation-associated protein Ebp1 from Homo sapiens is provided. ErbB-3-binding protein 1 (Ebp1) is a member of the family of proliferation-associated 2G4 proteins (PA2G4s) and plays a role in cellular growth and differentiation. Ligand-induced activation of the transmembrane receptor ErbB3 leads to dissociation of Ebp1 from the receptor in a phosphorylation-dependent manner. The non-associated protein is involved in transcriptional and translational regulation in the cell. Here, the overexpression, purification, crystallization and preliminary crystallographic studies of Ebp1 from Homo sapiens are reported. Initially observed crystals were improved by serial seeding to single crystals suitable for data collection. The optimized crystals belong to the tetragonal space group P4 1 2 1 2 or P4 3 2 1 2 and diffracted to a resolution of 1.6 Å

  16. Most significant preliminary results of the probabilistic safety analysis on the Juragua nuclear power plant

    International Nuclear Information System (INIS)

    Perdomo, Manuel

    1995-01-01

    Since 1990 the Group for PSA Development and Applications (GDA/APS) is working on the Level-1 PSA for the Juragua-1 NPP, as a part of an IAEA Technical Assistance Project. The main objective of this study, which is still under way, is to assess, in a preliminary way, the Reactor design safety to find its potential 'weak points' at the construction stage, using a eneric data base. At the same time, the study allows the PSA team to familiarize with the plant design and analysis techniques for the future operational PSA of the plant. This paper presents the most significant preliminary results of the study, which reveal some advantages of the safety characteristics of the plant design in comparison with the homologous VVER-440 reactors and some areas, where including slight modifications would improve the plant safety, considering the level of detail at which the study is carried out. (author). 13 refs, 1 fig, 2 tabs

  17. Characterization of inorganic compounds in nutritional supplements by the instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Nardi, Daniela T.; Saiki, Mitiko; Vasconcellos, Maria B.A.

    2000-01-01

    In this work instrumental neutron activation analysis was applied in the analyses of samples of nutritional supplements in order to evaluate the composition of their essential inorganic components. Results obtained in these analyses presented, in general, a good agreement with the label values. Precision and accuracy of the results were also evaluated by analyzing NIST 2704 Buffalo River Sediment and NIST 1400 Bone Ash reference materials. (author)

  18. The preparation of synthetic standards for use in instrumental neutron-activation analysis

    International Nuclear Information System (INIS)

    Eddy, B.T.; Watterson, J.I.W.; Erasmus, C.S.

    1979-01-01

    An account is given of the formulation and preparation of synthetic standards suitable for the routine analysis of minerals, ores, and ore concentrates by instrumental neutron activation. Fifteen standards were prepared, each containing from one to seven elements. The standards contain forty-four elements that produce isotopes with half-lives longer than 12 hours. An evaluation of the accuracy and precision of the method of preparation is given

  19. Characterization of ophiolites from northern Havana-Matanzas petroleum fields using instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Montero Cabrera, M.E. E-mail: montero@yakko.cimav.edu.mx; Ortueta Milan, M.; Herrera Peraza, E.F.; Herrera Hernandez, H.; Rodriguez Martinez, N.; Olivares Rieumont, S.; Lopez Reyes, M.C

    2001-01-15

    Concentrations of 16 elements from 14 serpentinitic samples from Basilio and Cantel petroleum fields were obtained by instrumental neutron activation analysis (INAA): Cr, Co, Ni, La, Nd, Sm, Eu, Gd, Tb, Ce Yb, Lu, Rb, Cs, Hf and Th. Relative INAA was performed using certified reference materials and laboratory standards. Average elemental concentrations showed that the ophiolites have a basic character, suggesting the use of a well-logging method designed for volcano-sedimentary petroleum fields.

  20. Instrumental neutron activation analysis of human hair and related radiotracer experiments on washing and leaching

    International Nuclear Information System (INIS)

    Das, H.A.; Hoede, D.; Sloot, H.A. van der; Herber, R.F.M.

    1981-11-01

    The work done under the IAEA-contract 2440/RB is summarized. The aim was to develop a fast and reliable system for the determination of tracer elements in human head hair by instrumental neutron activation analysis (INAA) and radiotracer washing experiments. The standardized procedure for INAA was applied to hair samples collected by the Coronel Laboratory of the University of Amsterdam. The correlation between trace element contents is considered

  1. Neutron xyz - polarization analysis at a time-of-flight instrument

    Energy Technology Data Exchange (ETDEWEB)

    Ehlers, Georg [ORNL; Stewart, John Ross [ISIS Facility, Rutherford Appleton Laboratory; Andersen, Ken [ESS

    2015-01-01

    When implementing a dedicated polarization analysis setup at a neutron time-of-flight instrument with a large area detector, one faces enormous challenges. Nevertheless, significant progress has been made towards this goal over the last few years. This paper addresses systematic limitations of the traditional method that is used to make these measurements, and a possible strategy to overcome these limitations. This will be important, for diffraction as well as inelastic experiments, where the scattering occurs mostly out-of-plane.

  2. Determination of toxic elements in tobacco products by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Ahmad, S.; Chaudhry, M.S.; Qureshi, I.H.

    1979-01-01

    The concentration of 15 elements in various brands of cigarette tobacco and cigarette wrapping paper were determined using instrumental neutron activation analysis. The paper of some of the brands contains higher concentrations of toxic elements than the tobacco. The cigarette filter and the ash were also analyzed to determine the adsorption of toxic elements on the filter and their transference in smoke. The toxic effects of some of the elements have been briefly discussed. (author)

  3. Salvinia auriculata: Aquatic bioindicator studied by instrumental neutron activation analysis (INAA)

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira Soares, Daniel Cristian; Figueiredo de Oliveira, Ester [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN), Avenida Antonio Carlos, 6627 Pampulha, CEP 30123-970 Belo Horizonte, Minas Gerais (Brazil); Fatima Silva, Gracia Divina de; Duarte, Lucienir Pains [Departamento de Quimica, ICEx, Nucleo de estudos de Plantas Medicinais (NEPLAM), Universidade Federal de Minas Gerais, Avenida Antonio Carlos, 6627 Pampulha, 31270-901 Belo Horizonte, Minas Gerais (Brazil); Pott, Vali Joana [Empresa Brasileira de Agropecuaria (EMBRAPA), BR 262 km 4, Caixa Postal 154, CEP 79002-970 Campo Grande, Mato Grosso do Sul (Brazil); Vieira Filho, Sidney Augusto [Escola de Farmacia, DEFAR, Universidade Federal de Ouro Preto, Rua Costa Sena, 171, CEP 35400-000 Ouro Preto, Minas Gerais (Brazil)], E-mail: bibo@ef.ufop.br

    2008-05-15

    Through instrumental neutron activation analysis (INAA) the elemental chemical composition of Salvinia auriculata and Ouro Preto city public water was determined. Elements Ce, Th, Cr, Hf, Sb, Sc, Rb, Fe, Zn, Co, Au, La and Br were quantified. High chromium concentration was determined in this plant. But, chromium was determined only in low concentrations in the water. The results indicate the great capacity of this plant to absorb and accumulate inorganic elements.

  4. Uses of instrumental neutron activation analysis (INAA) for lichen as bio indicators of environmental contamination

    International Nuclear Information System (INIS)

    Arribere, M.; Guevara, S.R.; Calvelo, S.

    1994-01-01

    Three species of epiphytic lichens were sampled at NW Patagonia, Argentina, from urban and peripherical forest area environments Sixty lichen samples were analysed individually by Instrumental Neutron Activation Analysis (INAA). The elements present in the samples were determined by parametric methods at the Neutron Activation Laboratory at Centro Atomico Bariloche, Argentina. All concentration values were normalized to Al concentration. The average normalized concentrations for each element, discriminated by species and environment, are presented in this work. (author). 11 refs, 6 tabs

  5. Characterization of ophiolites from northern Havana-Matanzas petroleum fields using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Montero Cabrera, M.E.; Ortueta Milan, M.; Herrera Peraza, E.F.; Herrera Hernandez, H.; Rodriguez Martinez, N.; Olivares Rieumont, S.; Lopez Reyes, M.C.

    2001-01-01

    Concentrations of 16 elements from 14 serpentinitic samples from Basilio and Cantel petroleum fields were obtained by instrumental neutron activation analysis (INAA): Cr, Co, Ni, La, Nd, Sm, Eu, Gd, Tb, Ce Yb, Lu, Rb, Cs, Hf and Th. Relative INAA was performed using certified reference materials and laboratory standards. Average elemental concentrations showed that the ophiolites have a basic character, suggesting the use of a well-logging method designed for volcano-sedimentary petroleum fields

  6. Mars Geochemical Instrument (MarGI): An instrument for the analysis of the Martian surface and the search for evidence of life

    Science.gov (United States)

    Kojiro, Daniel R.; Mancinelli, Rocco; Martin, Joe; Holland, Paul M.; Stimac, Robert M.; Kaye, William J.

    2005-01-01

    The Mars Geochemical Instrument, MarGI, was developed to provide a comprehensive analysis of the rocks and surface material on Mars. The instrument combines Differential Thermal Analysis (DTA) with miniature Gas Chromatography-Ion Mobility Spectrometry (GC-IMS) to identify minerals, the presence and state of water, and organic compounds. Miniature pyrolysis ovens are used to both, conduct DTA analysis of soil or crushed rocks samples, and pyrolyze the samples at temperatures up to 1000 degrees C for GC-IMS analysis of the released gases. This combination of analytical processes and techniques, which can characterize the mineralogy of the rocks and soil, and identify and quantify volatiles released during pyrolysis, has applications across a wide range of target sites including comets, planets, asteroids, and moons such as Titan and Europa. The MarGI analytical approach evolved from the Cometary Ice and Dust Experiment (CIDEX) selected to fly on the Comet Rendezvous Asteroid Flyby Mission (CRAF).

  7. Elemental analysis using instrumental neutron activation analysis and inductively coupled plasma atomic emission spectrometry: a comparative study

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Choi, Kwang Soon; Moon, Jong Hwa; Kim, Sun Ha; Lim, Jong Myoung; Kim, Young Jin; Quraishi, Shamshad Begum

    2003-05-01

    Elemental analyses for certified reference materials were carried out using instrumental neutron activation analysis and inductively coupled plasma-atomic emission spectrometry. Five Certified Reference Materials (CRM) were selected for the study on comparative analysis of environmental samples. The CRM are Soil (NIST SRM 2709), Coal fly ash (NIST SRM 1633a), urban dust (NIST SRM 1649a) and air particulate on filter media (NIST SRM 2783 and human hair (GBW 09101)

  8. Implementation of an ultrasonic instrument for simultaneous mixture and flow analysis of binary gas systems

    Energy Technology Data Exchange (ETDEWEB)

    Alhroob, M.; Boyd, G.; Hasib, A.; Pearson, B.; Srauss, M.; Young, J. [Department of Physics and Astronomy, University of Oklahoma, Norman, OK 73019, (United States); Bates, R.; Bitadze, A. [School of Physics and Astronomy, University of Glasgow, G12 8QQ, (United Kingdom); Battistin, M.; Berry, S.; Bonneau, P.; Botelho-Direito, J.; Bozza, G.; Crespo-Lopez, O.; DiGirolamo, B.; Favre, G.; Godlewski, J.; Lombard, D.; Zwalinski, L. [CERN, 1211 Geneva 23, (Switzerland); Bousson, N.; Hallewell, G.; Mathieu, M.; Rozanov, A. [Centre de Physique des Particules de Marseille, 163 Avenue de Luminy, 13288 Marseille Cedex 09, (France); Deterre, C.; O' Rourke, A. [Deutsches Elektronen-Synchrotron, Notkestrasse 85, D-22607 Hamburg, (Germany); Doubek, M.; Vacek, V. [Czech Technical University, Technick 4, 166 07 Prague 6, (Czech Republic); Degeorge, C. [Physics Department, Indiana University, Bloomington, IN 47405, (United States); Katunin, S. [B.P. Konstantinov Petersburg Nuclear Physics Institute (PNPI), 188300 St. Petersburg, (Russian Federation); Langevin, N. [Institut Universitaire de Technologie of Marseille, University of Aix-Marseille, 142 Traverse Charles Susini, 13013 Marseille, (France); McMahon, S. [Rutherford Appleton Laboratory - Science and Technology Facilities Council, Harwell Science and Innovation Campus, Didcot OX11 OQX, (United Kingdom); Nagai, K. [Department of Physics, Oxford University, Oxford OX1 3RH, (United Kingdom); Robinson, D. [Department of Physics and Astronomy, University of Cambridge, (United Kingdom); Rossi, C. [INFN - Genova, Via Dodecaneso 33, 16146 Genova, (Italy)

    2015-07-01

    Precision ultrasonic measurements in binary gas systems provide continuous real-time monitoring of mixture composition and flow. Using custom micro-controller-based electronics, we have developed an ultrasonic instrument, with numerous potential applications, capable of making continuous high-precision sound velocity measurements. The instrument measures sound transit times along two opposite directions aligned parallel to - or obliquely crossing - the gas flow. The difference between the two measured times yields the gas flow rate while their average gives the sound velocity, which can be compared with a sound velocity vs. molar composition look-up table for the binary mixture at a given temperature and pressure. The look-up table may be generated from prior measurements in known mixtures of the two components, from theoretical calculations, or from a combination of the two. We describe the instrument and its performance within numerous applications in the ATLAS experiment at the CERN Large Hadron Collider (LHC). The instrument can be of interest in other areas where continuous in-situ binary gas analysis and flowmetry are required. (authors)

  9. Trace elements evaluation of some medicinal herbs by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Zaidi, J.H.; Fatima, I.; Qureshi, I.H.; Subhani, M.S.

    2004-01-01

    Instrumental neutron activation analysis has been used for the analysis of seven varieties of medicinal herbs generally used by the people of South Asian region. Twenty-one trace elements (essential, toxic and non-essential) were determined. This data should not only be helpful in establishing the base-line values in these medicinal herbs but also in correlating their role as therapeutic agents. A comparison of our data with literature values shows variation in trace element contents of same species of different origin which can be attributed to ecological and geographical variations to some extent; however an exact interpretation demands further extensive investigations. (orig.)

  10. The instrumental neutron-activation analysis of granites from the Bushveld Complex

    International Nuclear Information System (INIS)

    Watterson, J.I.W.

    1978-01-01

    Three methods of instrumental neutron-activation analysis, 14MeV, reactor thermal, and reactor epithermal, are compared for the analysis of granites form the Bushveld Complex. A total of 34 elements can be determined in the granites by these methods. Samples from the Zaaiplaats area were analysed by thermal neutron activation, and 22 elements were determined in all of them. These elements were used to distinguish between the mineralized Bobbejaankop and Lease granites and the Main granite by the use of multivariate statistics. The Bobbejaankop granite appears as a more-differentaited rock carrying greater amounts of the incompatible elements than does the Main granite [af

  11. Preliminary design and off-design performance analysis of an Organic Rankine Cycle for geothermal sources

    International Nuclear Information System (INIS)

    Hu, Dongshuai; Li, Saili; Zheng, Ya; Wang, Jiangfeng; Dai, Yiping

    2015-01-01

    Highlights: • A method for preliminary design and performance prediction is established. • Preliminary data of radial inflow turbine and plate heat exchanger are obtained. • Off-design performance curves of critical components are researched. • Performance maps in sliding pressure operation are illustrated. - Abstract: Geothermal fluid of 90 °C and 10 kg/s can be exploited together with oil in Huabei Oilfield of China. Organic Rankine Cycle is regarded as a reasonable method to utilize these geothermal sources. This study conducts a detailed design and off-design performance analysis based on the preliminary design of turbines and heat exchangers. The radial inflow turbine and plate heat exchanger are selected in this paper. Sliding pressure operation is applied in the simulation and three parameters are considered: geothermal fluid mass flow rate, geothermal fluid temperature and condensing pressure. The results indicate that in all considered conditions the designed radial inflow turbine has smooth off-design performance and no choke or supersonic flow are found at the nozzle and rotor exit. The lager geothermal fluid mass flow rate, the higher geothermal fluid temperature and the lower condensing pressure contribute to the increase of cycle efficiency and net power. Performance maps are illustrated to make system meet different load requirements especially when the geothermal fluid temperature and condensing pressure deviate from the design condition. This model can be used to provide basic data for future detailed design, and predict off-design performance in the initial design phase

  12. Waste Feed Delivery System Phase 1 Preliminary RAM Analysis [SEC 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    DYKES, A.A.

    2000-10-11

    This report presents the updated results of the preliminary reliability, availability, and maintainability (RAM) analysis of selected waste feed delivery (WFD) operations to be performed by the Tank Farm Contractor (TFC) during Phase I activities in support of the Waste Treatment and Immobilization Plant (WTP). For planning purposes, waste feed tanks are being divided into five classes in accordance with the type of waste in each tank and the activities required to retrieve, qualify, and transfer waste feed. This report reflects the baseline design and operating concept, as of the beginning of Fiscal Year 2000, for the delivery of feed from three of these classes, represented by source tanks 241-AN-102, 241-AZ-101 and 241-AN-105. The preliminary RAM analysis quantifies the potential schedule delay associated with operations and maintenance (OBM) field activities needed to accomplish these operations. The RAM analysis is preliminary because the system design, process definition, and activity planning are in a state of evolution. The results are being used to support the continuing development of an O&M Concept tailored to the unique requirements of the WFD Program, which is being documented in various volumes of the Waste Feed Delivery Technical Basis (Carlson. 1999, Rasmussen 1999, and Orme 2000). The waste feed provided to the WTP must: (1) meet limits for chemical and radioactive constituents based on pre-established compositional envelopes (i.e., feed quality); (2) be in acceptable quantities within a prescribed sequence to meet feed quantities; and (3) meet schedule requirements (i.e., feed timing). In the absence of new criteria related to acceptable schedule performance due to the termination of the TWRS Privatization Contract, the original criteria from the Tank Waste Remediation System (77443s) Privatization Contract (DOE 1998) will continue to be used for this analysis.

  13. Recent developments in X-ray and neutron small-angle scattering instrumentation and data analysis

    International Nuclear Information System (INIS)

    Schelten, J.

    1978-01-01

    The developments in instrumentation and data analysis that have occurred in the field of small-angle X-ray and neutron scattering since 1973 are reviewed. For X-rays, the cone camera collimation was invented, synchrotrons and storage rings were demonstrated to be intense sources of X-radiation, and one- and two-dimensional position-sensitive detectors were interfaced to cameras with both point and line collimation. For neutrons, the collimators and detectors on the Juelich and Grenoble machines were improved, new D11-type instruments were built or are under construction at several sites, double-crystal instruments were set up, and various new machines have been proposed. Significant progress in data analysis and evaluation has been made through application of mathematical techniques such as the use of spline functions, error minimization with constraints, and linear programming. Several special experiments, unusual in respect to the anisotropy of the scattering pattern, gravitational effects, moving scatterers, and dynamic fast time slicing, are discussed. (Auth.)

  14. Recent advances in the instrumental techniques for the analysis of modern materials (II)

    International Nuclear Information System (INIS)

    Ahmed, M.

    1990-01-01

    Inductively Coupled Plasma Mass Spectrometry ICP-MS a logical development of equally established sister technique of ICP-AEA discussed in part-1 of this series of article on modern analytical techniques. The rapid adaptation of argon plasma as ion source for time of flight quadrupole mass analyser has led to the development of truly integrated instrumental technique for analysis of solutions and slurries. The powerful combination with laser ablation device has made the direct analysis of geological, geochemical and other complex conducting and non conducting samples possible in days rather months at sub ppm levels. Parallel development in computer hardware and software has made the instrumental optimization easy enabling the generation of meaningful analytical data a matter of routine. The limitations imposed by spectroscopic and non restricted the variety of matrices and materials covered by ICP-MS of LA-ICP-MS. The technique has provided it formidable analytical power in wide areas of industrial environmental, social, biological and break through advanced materials used in space mass communication, transportation and general areas of advanced analytical chemistry. It is expected that in combination with other instrumental methods as HPLC, ETC, ion chromatography. ICP-MS shall continue to dominate well into the 21st century. (author)

  15. A new instrumental method for the analysis of rare earth elements

    International Nuclear Information System (INIS)

    Santos, A.N. dos.

    1975-01-01

    A method for the simultaneous elemental analysis of the rare earths is proposed and empirically verified. It is based on the analysis of the escape peaks, generated by the characteristic X-rays of these elements in a xenon proportional counter. The peaks are well resolved and intense, in contrast to the photopeak which is lost in the background. The spectra are generated by a radioisotope such as Co 57 , and the equipment is simple, portable and low cost, although resolution challenges that of the best solid state detectors. Since X-rays are utilized, matrix, granulometric or mineralogical effects are minimal, and the method is rapid, sensitive, non-destructive and requires little or no sample preparation. The results are preliminary and an improvement in resolution of up to fourfold seems possible; precision is better than 0,1% in concentrated samples and sensitivity is about 20 μg

  16. Preliminary analysis for model development of groundwater evolution in Horonobe area

    International Nuclear Information System (INIS)

    Yoshida, Yasushi; Yui, Mikazu

    2003-03-01

    The preliminary analysis for model development of groundwater evolution in Horonobe area was performed with data at D-1, HDB-1 and HDB-2 bore hole where hydrogen / oxygen isotope concentration, mineral property in sedimentary rock and physico-chemical parameters (pH, Eh and ionic concentrations) were measured. As a result of analysis for hydrogen and oxygen isotope concentration, saline water in marine sediment was diluted by the mixing with shallow groundwater and diffusion. And as a result of analysis for a concentration of bicarbonate from the difference of pH values measured between in-situ and under air, the estimated in-situ concentration of bicarbonate differs from that measured under air. And minerals which were assumed to be equilibrium with groundwater were selected by thermodynamic calculation. This report presents the results of preliminary analysis for groundwater evolution by using data derived from D-1, HDB-1 and HDB-2 boring research. In order to establish the model which interprets the groundwater evolution as a next step, data which satisfy the representative in-situ property of groundwater chemistry in Horonobe area are needed. Reliable measurements for physico-chemical parameter and property of minerals in sedimentary rock in dominant layer and at the variety of depth are also needed. (author)

  17. Ares-I-X Vehicle Preliminary Range Safety Malfunction Turn Analysis

    Science.gov (United States)

    Beaty, James R.; Starr, Brett R.; Gowan, John W., Jr.

    2008-01-01

    Ares-I-X is the designation given to the flight test version of the Ares-I rocket (also known as the Crew Launch Vehicle - CLV) being developed by NASA. As part of the preliminary flight plan approval process for the test vehicle, a range safety malfunction turn analysis was performed to support the launch area risk assessment and vehicle destruct criteria development processes. Several vehicle failure scenarios were identified which could cause the vehicle trajectory to deviate from its normal flight path, and the effects of these failures were evaluated with an Ares-I-X 6 degrees-of-freedom (6-DOF) digital simulation, using the Program to Optimize Simulated Trajectories Version 2 (POST2) simulation framework. The Ares-I-X simulation analysis provides output files containing vehicle state information, which are used by other risk assessment and vehicle debris trajectory simulation tools to determine the risk to personnel and facilities in the vicinity of the launch area at Kennedy Space Center (KSC), and to develop the vehicle destruct criteria used by the flight test range safety officer. The simulation analysis approach used for this study is described, including descriptions of the failure modes which were considered and the underlying assumptions and ground rules of the study, and preliminary results are presented, determined by analysis of the trajectory deviation of the failure cases, compared with the expected vehicle trajectory.

  18. Extracting Loop Bounds for WCET Analysis Using the Instrumentation Point Graph

    Science.gov (United States)

    Betts, A.; Bernat, G.

    2009-05-01

    Every calculation engine proposed in the literature of Worst-Case Execution Time (WCET) analysis requires upper bounds on loop iterations. Existing mechanisms to procure this information are either error prone, because they are gathered from the end-user, or limited in scope, because automatic analyses target very specific loop structures. In this paper, we present a technique that obtains bounds completely automatically for arbitrary loop structures. In particular, we show how to employ the Instrumentation Point Graph (IPG) to parse traces of execution (generated by an instrumented program) in order to extract bounds relative to any loop-nesting level. With this technique, therefore, non-rectangular dependencies between loops can be captured, allowing more accurate WCET estimates to be calculated. We demonstrate the improvement in accuracy by comparing WCET estimates computed through our HMB framework against those computed with state-of-the-art techniques.

  19. Long Term Analysis of Adaptive Low-Power Instrument Platform Power and Battery Performance

    Science.gov (United States)

    Edwards, T.; Bowman, J. R.; Clauer, C. R.

    2017-12-01

    Operation of the Autonomous Adaptive Low-Power Instrument Platform (AAL-PIP) by the Magnetosphere-Ionosphere Science Team (MIST) at Virginia Tech has been ongoing for about 10 years. These instrument platforms are deployed on the East Antarctic Plateau in remote locations that are difficult to access regularly. The systems have been designed to operate unattended for at least 5 years. During the Austral summer, the systems charge batteries using solar panels and power is provided by the batteries during the winter months. If the voltage goes below a critical level, the systems go into hibernation and wait for voltage from the solar panels to initiate a restart sequence to begin operation and battery charging. Our first system was deployed on the East Antarctic Plateau in 2008 and we report here on an analysis of the power and battery performance over multiple years and provide an estimate for how long these systems can operate before major battery maintenance must be performed.

  20. Fruit of Morus nigra and Morus alba as environmental biomonitor. An elemental analysis by k0-instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Mohammad Wasim; Sajid Iqbal; Sohaila Rahman

    2016-01-01

    In this study, potential of fruit of Morus nigra and Morus alba was evaluated as short-term biomonitor. Each variety of the fruits was collected from 13 different locations of Islamabad with different level of pollution. Both fruits were quantified by k 0 -instrumental neutron activation analysis. Pollution level was assessed by the application of enrichment factor (EF) and principal component analysis (PCA). EF revealed a source of (As, Hg, I and Se) and PCA showed the areas of high dust level. The overall analysis suggested that both fruits could be used as short-term biomonitor. (author)

  1. Application of instrumental neutron activation analysis for the examination of oil pigments

    International Nuclear Information System (INIS)

    Chung, Y.S.; Kim, S.H.; Sun, G.M.; Lim, J.M.; Moon, J.H.; Kim, Y.J.; Lim, S.J.; Song, Y.N.; Kim, K.

    2011-01-01

    This study is to investigate the applicability of instrumental neutron activation analysis (INAA) as a non-destructive examination tool for the quantitative chemical composition analysis associated with authentication, restoration and conservation of art objects in the field of cultural heritage. The quantitative analysis of major, minor and trace elements in Rembrandt's registered oil pigments recently collected at the Korean market as one of the art objects was carried out using INAA facilities of the HANARO research reactor at the Korea Atomic Energy Research Institute in collaboration with the National Museum of Contemporary Art in Korea. Analytical quality control was implemented using NIST SRM 2709, certified reference materials and metal standards. The analytical results for seventeen characteristic elements of thirty-one measured elements were statistically treated to identify the characteristic correlations and patterns between color and source of oil pigment and similarity degree of constituents using a cluster and discriminate analysis. (orig.)

  2. Application of instrumental neutron activation analysis for the examination of oil pigments

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y.S.; Kim, S.H.; Sun, G.M.; Lim, J.M.; Moon, J.H.; Kim, Y.J. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lim, S.J.; Song, Y.N.; Kim, K. [National Museum of Contemporary Art, Gwacheon, Gyeonggi-do (Korea, Republic of)

    2011-07-01

    This study is to investigate the applicability of instrumental neutron activation analysis (INAA) as a non-destructive examination tool for the quantitative chemical composition analysis associated with authentication, restoration and conservation of art objects in the field of cultural heritage. The quantitative analysis of major, minor and trace elements in Rembrandt's {sup registered} oil pigments recently collected at the Korean market as one of the art objects was carried out using INAA facilities of the HANARO research reactor at the Korea Atomic Energy Research Institute in collaboration with the National Museum of Contemporary Art in Korea. Analytical quality control was implemented using NIST SRM 2709, certified reference materials and metal standards. The analytical results for seventeen characteristic elements of thirty-one measured elements were statistically treated to identify the characteristic correlations and patterns between color and source of oil pigment and similarity degree of constituents using a cluster and discriminate analysis. (orig.)

  3. A preliminary analysis of the risk of transporting nuclear waste to potential candidate commercial repository sites

    International Nuclear Information System (INIS)

    Madsen, M.M.

    1984-01-01

    In accordance with the provisions of the Nuclear Waste Policy Act of 1982, environmental assessments for potential candidate sites are required to provide a basis for selection of the first site for disposal of commercial radioactive waste in deep geologic repositories. A preliminary analysis of the impacts of transportation for each of the five potential sites will be described. Transportation was assumed to be entirely by truck or entirely by rail in order to obtain bounding impacts. This paper presents both radiological and nonradiological risks for the once-through fuel cycle

  4. Foregrounds in the BOOMERANG-LDB data: a preliminary rms analysis

    OpenAIRE

    Masi, S.; Ade, P. A. R.; Bock, J.; Boscaleri, A.; Crill, B. P.; de Bernardis, P.; Ganga, K.; Giacometti, M.; Hivon, E.; Hristov, V. V.; Lange, A. E.; Martinis, L.; Mauskopf, P. D.; Montroy, T.; Netterfield, C. B.

    2000-01-01

    We present a preliminary analysis of the BOOMERanG LDB maps, focused on foregrounds. BOOMERanG detects dust emission at moderately low galactic latitudes ($b > -20^o$) in bands centered at 90, 150, 240, 410 GHz. At higher Galactic latitudes, we use the BOOMERanG data to set conservative upper limits on the level of contamination at 90 and 150 GHz. We find that the mean square signal correlated with the IRAS/DIRBE dust template is less than 3% of the mean square signal due to CMB anisotropy.

  5. Documentation of Hanford Site independent review of the Hanford Waste Vitrification Plant Preliminary Safety Analysis Report

    International Nuclear Information System (INIS)

    Herborn, D.I.

    1991-10-01

    The requirements for Westinghouse Hanford independent review of the Preliminary Safety Analysis Report (PSAR) are contained in Section 1.0, Subsection 4.3 of WCH-CM-4-46. Specifically, this manual requires the following: (1) Formal functional reviews of the HWVP PSAR by the future operating organization (HWVP Operations), and the independent review organizations (HWVP and Environmental Safety Assurance, Environmental Assurance, and Quality Assurance); and (2) Review and approval of the HWVP PSAR by the Tank Waste Disposal (TWD) Subcouncil of the Safety and Environmental Advisory Council (SEAC), which provides independent advice to the Westinghouse Hanford President and executives on matters of safety and environmental protection. 7 refs

  6. Preliminary study of energy confinement data with a statistical analysis system in HL-2A tokamak

    International Nuclear Information System (INIS)

    Xu Yuan; Cui Zhengying; Ji Xiaoquan; Dong Chunfeng; Yang Qingwei; O J W F Kardaun

    2010-01-01

    Taking advantage of the HL-2A experimental data,an energy confinement database facing ITERL DB2.0 version has been originally established. As for this database,a world widely used statistical analysis system (SAS) has been adopted for the first time to analyze and evaluate the confinement data from HL-2A and the research on scaling laws of energy confinement time corresponding to plasma density is developed, some preliminary results having been achieved. Finally, through comparing with both ITER scaling law and previous ASDEX database, the investigation about L-mode confinement quality on HL-2A and influence of temperature on Spitzer resistivity will be discussed. (authors)

  7. Geoscientific long-term prognosis. Preliminary safety analysis for the site Gorleben

    International Nuclear Information System (INIS)

    Mrugalla, Sabine

    2011-07-01

    The preliminary safety analysis of the site Gorleben includes the following chapters: (1) Introduction; (2) Aim and content of the geoscientific long-term prognosis for the site Gorleben; (3) Boundary conditions at the site Gorleben: climate; geomorphology; overlying rocks and adjoining rocks; hydrogeology; salt deposit Gorleben. (4) Probable future geological developments at the site Gorleben: supraregional developments with effects on the site Gorleben; glacial period developments; developments of the geomorphology, overlying and adjoining rocks; future developments of the hydrological systems at the site Gorleben; future saliniferous specific developments of the salt deposit Gorleben. (5) Commentary on the unlikely or excludable developments of the site Gorleben.

  8. Andragogy's Transition into the Future: Meta-Analysis of Andragogy and Its Search for a Measurable Instrument

    Science.gov (United States)

    Taylor, Bryan; Kroth, Michael

    2009-01-01

    This article is a meta-analysis of the theory of andragogy and its search for a measurable instrument. The article explores three areas surrounding andragogy: (a) its concept and history, (b) its assumptions, and (c) its primary criticisms. In examining these three areas, a foundation is established for the creation of an instrument to provide…

  9. Preliminary Report: Analysis of the baseline study on the prevalence of Salmonella in laying hen flocks of Gallus gallus

    DEFF Research Database (Denmark)

    Hald, Tine

    This is a preliminary report on the analysis of the Community-wide baseline study to estimate the prevalence of Salmonella in laying hen flocks. It is being published pending the full analysis of the entire dataset from the baseline study. The report contains the elements necessary for the establ......This is a preliminary report on the analysis of the Community-wide baseline study to estimate the prevalence of Salmonella in laying hen flocks. It is being published pending the full analysis of the entire dataset from the baseline study. The report contains the elements necessary...

  10. Analysis of kinematic, kinetic and electromyographic patterns during root canal preparation with rotary and manual instruments

    Directory of Open Access Journals (Sweden)

    Braulio Pasternak-Júnior

    2012-02-01

    Full Text Available OBJECTIVE: This study assessed the muscular activity during root canal preparation through kinematics, kinetics, and electromyography (EMG. MATERIAL AND METHODS: The operators prepared one canal with RaCe rotary instruments and another with Flexo-files. The kinematics of the major joints was reconstructed using an optoelectronic system and electromyographic responses of the flexor carpi radialis, extensor carpi radialis, brachioradialis, biceps brachii, triceps brachii, middle deltoid, and upper trapezius were recorded. The joint torques of the shoulder, elbow and wrist were calculated using inverse dynamics. In the kinematic analysis, angular movements of the wrist and elbow were classified as low risk factors for work-related musculoskeletal disorders. With respect to the shoulder, the classification was medium-risk. RESULTS: There was no significant difference revealed by the kinetic reports. The EMG results showed that for the middle deltoid and upper trapezius the rotary instrumentation elicited higher values. The flexor carpi radialis and extensor carpi radialis, as well as the brachioradialis showed a higher value with the manual method. CONCLUSION: The muscular recruitment for accomplishment of articular movements for root canal preparation with either the rotary or manual techniques is distinct. Nevertheless, the rotary instrument presented less difficulty in the generation of the joint torque in each articulation, thus, presenting a greater uniformity of joint torques.

  11. Analysis of kinematic, kinetic and electromyographic patterns during root canal preparation with rotary and manual instruments

    Science.gov (United States)

    PASTERNAK-JÚNIOR, Braulio; de SOUSA NETO, Manoel Damião; DIONÍSIO, Valdeci Carlos; PÉCORA, Jesus Djalma; SILVA, Ricardo Gariba

    2012-01-01

    Objective This study assessed the muscular activity during root canal preparation through kinematics, kinetics, and electromyography (EMG). Material and Methods The operators prepared one canal with RaCe rotary instruments and another with Flexo-files. The kinematics of the major joints was reconstructed using an optoelectronic system and electromyographic responses of the flexor carpi radialis, extensor carpi radialis, brachioradialis, biceps brachii, triceps brachii, middle deltoid, and upper trapezius were recorded. The joint torques of the shoulder, elbow and wrist were calculated using inverse dynamics. In the kinematic analysis, angular movements of the wrist and elbow were classified as low risk factors for work-related musculoskeletal disorders. With respect to the shoulder, the classification was medium-risk. Results There was no significant difference revealed by the kinetic reports. The EMG results showed that for the middle deltoid and upper trapezius the rotary instrumentation elicited higher values. The flexor carpi radialis and extensor carpi radialis, as well as the brachioradialis showed a higher value with the manual method. Conclusion The muscular recruitment for accomplishment of articular movements for root canal preparation with either the rotary or manual techniques is distinct. Nevertheless, the rotary instrument presented less difficulty in the generation of the joint torque in each articulation, thus, presenting a greater uniformity of joint torques. PMID:22437679

  12. Apical extrusion of debris in four different endodontic instrumentation systems: A meta-analysis.

    Science.gov (United States)

    Western, J Sylvia; Dicksit, Daniel Devaprakash

    2017-01-01

    All endodontic instrumentation systems tested so far, promote apical extrusion of debris, which is one of the main causes of postoperative pain, flare ups, and delayed healing. Of this meta-analysis was to collect and analyze in vitro studies quantifying apically extruded debris while using Hand ProTaper (manual), ProTaper Universal (rotary), Wave One (reciprocating), and self-adjusting file (SAF; vibratory) endodontic instrumentation systems and to determine methods which produced lesser extrusion of debris apically. An extensive electronic database search was done in PubMed, Scopus, Cochrane, LILACS, and Google Scholar from inception until February 2016 using the key terms "Apical Debris Extrusion, extruded material, and manual/rotary/reciprocating/SAF systems." A systematic search strategy was followed to extract 12 potential articles from a total of 1352 articles. The overall effect size was calculated from the raw mean difference of weight of apically extruded debris. Statistically significant difference was seen in the following comparisons: SAF ProTaper. Apical extrusion of debris was invariably present in all the instrumentation systems analyzed. SAF system seemed to be periapical tissue friendly as it caused reduced apical extrusion compared to Rotary ProTaper and Wave One.

  13. Portable generator-based X RF instrument for non-destructive analysis at crime scenes

    Energy Technology Data Exchange (ETDEWEB)

    Schweitzer, Jeffrey S. [University of Connecticut, Department of Physics, Unit 3046 Storrs, CT 06269-3046 (United States)]. E-mail: schweitz@phys.uconn.edu; Trombka, Jacob I. [Goddard Space Flight Center, Code 691, Greenbelt Road, Greenbelt, MD 20771 (United States); Floyd, Samuel [Goddard Space Flight Center, Code 691, Greenbelt Road, Greenbelt, MD 20771 (United States); Selavka, Carl [Massachusetts State Police Crime Laboratory, 59 Horse Pond Road, Sudbury, MA 01776 (United States); Zeosky, Gerald [Forensic Investigation Center, Crime Laboratory Building, 22 State Campus, Albany, NY 12226 (United States); Gahn, Norman [Assistant District Attorney, Milwaukee County, District Attorney' s Office, 821 West State Street, Milwaukee, WI 53233-1427 (United States); McClanahan, Timothy [Goddard Space Flight Center, Code 691, Greenbelt Road, Greenbelt, MD 20771 (United States); Burbine, Thomas [Goddard Space Flight Center, Code 691, Greenbelt Road, Greenbelt, MD 20771 (United States)

    2005-12-15

    Unattended and remote detection systems find applications in space exploration, telemedicine, teleforensics, homeland security and nuclear non-proliferation programs. The National Institute of Justice (NIJ) and the National Aeronautics and Space Administration's (NASA) Goddard Space Flight Center (GSFC) have teamed up to explore the use of NASA developed technologies to help criminal justice agencies and professionals investigate crimes. The objective of the program is to produce instruments and communication networks that have application within both NASA's space program and NIJ, together with state and local forensic laboratories. A general-purpose X-ray fluorescence system has been built for non-destructive analyses of trace and invisible material at crime scenes. This portable instrument is based on a generator that can operate to 60 kV and a Schottky CdTe detector. The instrument has been shown to be successful for the analysis of gunshot residue and a number of bodily fluids at crime scenes.

  14. The Inner Magnetospheric Imager (IMI): Instrument heritage and orbit viewing analysis

    Science.gov (United States)

    Wilson, Gordon R.

    1992-12-01

    For the last two years an engineering team in the Program Development Office at MSFC has been doing design studies for the proposed Inner Magnetospheric Imager (IMI) mission. This team had a need for more information about the instruments that this mission would carry so that they could get a better handle on instrument volume, mass, power, and telemetry needs as well as information to help assess the possible cost of such instruments and what technology development they would need. To get this information, an extensive literature search was conducted as well as interviews with several members of the IMI science working group. The results of this heritage survey are summarized below. There was also a need to evaluate the orbits proposed for this mission from the stand point of their suitability for viewing the various magnetospheric features that are planned for this mission. This was accomplished by first, identifying the factors which need to be considered in selecting an orbit, second, translating these considerations into specific criteria, and third, evaluating the proposed orbits against these criteria. The specifics of these criteria and the results of the orbit analysis are contained in the last section of this report.

  15. Instrumental analysis of low level of Cs-137 in marine samples by gamma spectrometry; Analise instrumental de baixos niveis de Cs-137 em amostras marinhas por espectrometria gama

    Energy Technology Data Exchange (ETDEWEB)

    Figueira, Rubens C.L.; Silva, Luiz R.N.; Figueiredo, Ana M.G.; Cunha, Ieda I.L. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Supervisao de Radioquimica

    1997-12-31

    An instrumental method for low level Cs-137 analysis in marine samples is presented. The method consists in the detector calibration, as well as, determination of detector counting efficiency, accumulative counting of both background and sample and smoothing of 661.6 keV photopeak. The methodology was applied in reference samples and in sediments samples of south Brazilian coast 11 refs., 6 figs., 4 tabs.; e-mail: figueira at net.ipen.br

  16. Preliminary phytochemical screening, Antibacterial potential and GC-MS analysis of two medicinal plant extracts.

    Science.gov (United States)

    Vijayaram, Seerangaraj; Kannan, Suruli; Saravanan, Konda Mani; Vasantharaj, Seerangaraj; Sathiyavimal, Selvam; P, Palanisamy Senthilkumar

    2016-05-01

    The presence study was aimed to catalyze the primary metabolites and their confirmation by using GC-MS analysis and antibacterial potential of leaf extract of two important medicinal plant viz., Eucalyptus and Azadirachta indica. The antibacterial potential of the methanol leaf extract of the studied species was tested against Escherichia coli, Pseudomonas aeruginosa, Klebsiellap neumoniae, Streptococcus pyogens, Staphylococcus aureus using by agar well diffusion method. The higher zone of inhibition (16mm) was observed against the bacterium Pseudomonas aeruginosa at 100μl concentration of methanol leaf extract. Preliminary phytochemical analysis of studied species shows that presence of phytochemical compounds like steroids, phenolic compounds and flavonoids. GC-MS analysis confirms the occurrence of 20 different compounds in the methanol leaf extract of the both studied species.

  17. 1972 preliminary safety analysis report based on a conceptual design of a proposed repository in Kansas

    International Nuclear Information System (INIS)

    Blomeke, J.O.

    1977-08-01

    This preliminary safety analysis report is based on a proposed Federal Repository at Lyons, Kansas, for receiving, handling, and depositing radioactive solid wastes in bedded salt during the remainder of this century. The safety analysis applies to a hypothetical site in central Kansas identical to the Lyons site, except that it is free of nearby salt solution-mining operations and bore holes that cannot be plugged to Repository specifications. This PSAR contains much information that also appears in the conceptual design report. Much of the geological-hydrological information was gathered in the Lyons area. This report is organized in 16 sections: considerations leading to the proposed Repository, design requirements and criteria, a description of the Lyons site and its environs, land improvements, support facilities, utilities, different impacts of Repository operations, safety analysis, design confirmation program, operational management, requirements for eventually decommissioning the facility, design criteria for protection from severe natural events, and the proposed program of experimental investigations

  18. Modeling and preliminary thermal analysis of the capsule for a creep test in HANARO

    International Nuclear Information System (INIS)

    Choi, Myoung Hwan; Cho, Man Soon; Choo, Kee Nam; Kang, Young Hwan; Sohn, Jae Min; Shin, Yoon Taeg; Park, Sung Jae; Kim, Bong Goo; Kim, Young Jin

    2005-01-01

    A creep capsule is a device to investigate the creep characteristics of nuclear materials during inpile irradiation tests. To obtain the design data of the capsule through a preliminary thermal analysis, a 2-dimensional model for the cross section of the capsule including the specimens and components is generated, and an analysis using the ANSYS program is performed. The gamma-heating rates of the materials for the HANARO power of 30MW are considered, and the effect of the gap size and the control rod position on the temperature of the specimen is discussed. From the analysis it is found that the gap between the thermal media and the external tube has a significant effect on the temperature of the specimen. The temperature by increasing the position of the control rod is decreased

  19. 1972 preliminary safety analysis report based on a conceptual design of a proposed repository in Kansas

    Energy Technology Data Exchange (ETDEWEB)

    Blomeke, J.O.

    1977-08-01

    This preliminary safety analysis report is based on a proposed Federal Repository at Lyons, Kansas, for receiving, handling, and depositing radioactive solid wastes in bedded salt during the remainder of this century. The safety analysis applies to a hypothetical site in central Kansas identical to the Lyons site, except that it is free of nearby salt solution-mining operations and bore holes that cannot be plugged to Repository specifications. This PSAR contains much information that also appears in the conceptual design report. Much of the geological-hydrological information was gathered in the Lyons area. This report is organized in 16 sections: considerations leading to the proposed Repository, design requirements and criteria, a description of the Lyons site and its environs, land improvements, support facilities, utilities, different impacts of Repository operations, safety analysis, design confirmation program, operational management, requirements for eventually decommissioning the facility, design criteria for protection from severe natural events, and the proposed program of experimental investigations. (DLC)

  20. Preliminary Computational Analysis of the (HIRENASD) Configuration in Preparation for the Aeroelastic Prediction Workshop

    Science.gov (United States)

    Chwalowski, Pawel; Florance, Jennifer P.; Heeg, Jennifer; Wieseman, Carol D.; Perry, Boyd P.

    2011-01-01

    This paper presents preliminary computational aeroelastic analysis results generated in preparation for the first Aeroelastic Prediction Workshop (AePW). These results were produced using FUN3D software developed at NASA Langley and are compared against the experimental data generated during the HIgh REynolds Number Aero- Structural Dynamics (HIRENASD) Project. The HIRENASD wind-tunnel model was tested in the European Transonic Windtunnel in 2006 by Aachen University0s Department of Mechanics with funding from the German Research Foundation. The computational effort discussed here was performed (1) to obtain a preliminary assessment of the ability of the FUN3D code to accurately compute physical quantities experimentally measured on the HIRENASD model and (2) to translate the lessons learned from the FUN3D analysis of HIRENASD into a set of initial guidelines for the first AePW, which includes test cases for the HIRENASD model and its experimental data set. This paper compares the computational and experimental results obtained at Mach 0.8 for a Reynolds number of 7 million based on chord, corresponding to the HIRENASD test conditions No. 132 and No. 159. Aerodynamic loads and static aeroelastic displacements are compared at two levels of the grid resolution. Harmonic perturbation numerical results are compared with the experimental data using the magnitude and phase relationship between pressure coefficients and displacement. A dynamic aeroelastic numerical calculation is presented at one wind-tunnel condition in the form of the time history of the generalized displacements. Additional FUN3D validation results are also presented for the AGARD 445.6 wing data set. This wing was tested in the Transonic Dynamics Tunnel and is commonly used in the preliminary benchmarking of computational aeroelastic software.

  1. Bioanalytical and instrumental analysis of thyroid hormone disrupting compounds in water sources along the Yangtze River

    International Nuclear Information System (INIS)

    Shi Wei; Wang Xiaoyi; Hu Guanjiu; Hao Yingqun; Zhang Xiaowei; Liu Hongling; Wei Si; Wang Xinru; Yu Hongxia

    2011-01-01

    Thyroid hormone (TH) agonist and antagonist activities of water sources along the Yangtze River in China were surveyed by a green monkey kidney fibroblast (CV-1) cell-based TH reporter gene assay. Instrumental analysis was conducted to identify the responsible thyroid-active compounds. Instrumentally derived L-3,5,3'-triiodothyronine (T 3 ) equivalents (T 3 -EQs) and thyroid receptor (TR) antagonist activity equivalents referring to dibutyl phthalate (DBP-EQs) were calculated from the concentrations of individual congeners. The reporter gene assay demonstrated that three out of eleven water sources contained TR agonist activity equivalents (TR-EQs), ranging from 286 to 293 ng T 3 /L. Anti-thyroid hormone activities were found in all water sources with the TR antagonist activity equivalents referring to DBP (Ant-TR-EQs), ranging from 51.5 to 555.3 μg/L. Comparisons of the equivalents from instrumental and biological assays suggested that high concentrations of DBP and di-2-ethylhexyl phthalate (DEHP) were responsible for the observed TR antagonist activities at some locations along the Yangtze River. - Research highlights: → First of all, we indicated the instrumentally derived L-3,5,3'-triiodothyronine (T 3 ) equivalents (T 3 -EQs) and thyroid receptor (TR) antagonist activity equivalents referring to DBP (DBP-EQs) for the very first time. → Secondly, high concentrations of DBP and DEHP might be responsible for the observed TR antagonist activities at some locations. → Finally, we found that thyroid receptor (TR) antagonist activities were very common in Yangtze River. More attentions should be paid to the TR antagonist activities and the responsible compounds. - In vitro bioassay responses observed in Yangtze River source water extracts showed great TR antagonist activities, and DBP and DEHP were responsible.

  2. Bioanalytical and instrumental analysis of thyroid hormone disrupting compounds in water sources along the Yangtze River

    Energy Technology Data Exchange (ETDEWEB)

    Shi Wei [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210093 (China); Wang Xiaoyi [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210093 (China); Jiangsu Academy of Environmental Science, Nanjing 210036 (China); Hu Guanjiu; Hao Yingqun [State Environmental Protection Key Laboratory of Monitoring and Analysis for Organic Pollutants in Surface Water, Jiangsu Provincial Environmental Monitoring Center, Nanjing 210036 (China); Zhang Xiaowei [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210093 (China); Liu Hongling, E-mail: hlliu@nju.edu.c [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210093 (China); Wei Si [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210093 (China); Wang Xinru [Key Laboratory of Reproductive Medicine and Institute of Toxicology, Nanjing Medical University, Nanjing 210029 (China); Yu Hongxia, E-mail: hongxiayu@nju.edu.c [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210093 (China)

    2011-02-15

    Thyroid hormone (TH) agonist and antagonist activities of water sources along the Yangtze River in China were surveyed by a green monkey kidney fibroblast (CV-1) cell-based TH reporter gene assay. Instrumental analysis was conducted to identify the responsible thyroid-active compounds. Instrumentally derived L-3,5,3'-triiodothyronine (T{sub 3}) equivalents (T{sub 3}-EQs) and thyroid receptor (TR) antagonist activity equivalents referring to dibutyl phthalate (DBP-EQs) were calculated from the concentrations of individual congeners. The reporter gene assay demonstrated that three out of eleven water sources contained TR agonist activity equivalents (TR-EQs), ranging from 286 to 293 ng T{sub 3}/L. Anti-thyroid hormone activities were found in all water sources with the TR antagonist activity equivalents referring to DBP (Ant-TR-EQs), ranging from 51.5 to 555.3 {mu}g/L. Comparisons of the equivalents from instrumental and biological assays suggested that high concentrations of DBP and di-2-ethylhexyl phthalate (DEHP) were responsible for the observed TR antagonist activities at some locations along the Yangtze River. - Research highlights: First of all, we indicated the instrumentally derived L-3,5,3'-triiodothyronine (T{sub 3}) equivalents (T{sub 3}-EQs) and thyroid receptor (TR) antagonist activity equivalents referring to DBP (DBP-EQs) for the very first time. Secondly, high concentrations of DBP and DEHP might be responsible for the observed TR antagonist activities at some locations. Finally, we found that thyroid receptor (TR) antagonist activities were very common in Yangtze River. More attentions should be paid to the TR antagonist activities and the responsible compounds. - In vitro bioassay responses observed in Yangtze River source water extracts showed great TR antagonist activities, and DBP and DEHP were responsible.

  3. Determination of catalyst residues in hydrocarbon fuels by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Burgess, D.D.

    1982-01-01

    A procedure has been developed for the determination of entrained catalytic cracking catalyst in hydrocarbon fuels. Aluminium is measured by instrumental neutron activation analysis and the amount of catalyst present is calculated from the amount of aluminium found and the known composition of the catalyst. Entrained catalyst may be determined at levels above 3 ppm with a precision of +-2%-25% according to sample composition. Only simple procedures are required. Vanadium may reduce sensitivity by dead time and pulse pile-up. No other interferences were observed. (author)

  4. Instrumental neutron activities analysis of Marrubium vulgare L., a valuable medicinal herb

    Energy Technology Data Exchange (ETDEWEB)

    Nedjimi, Bouzid [Djelfa Univ. (Algeria). Lab. of Exploration and Valorization of Steppe Ecosystem; Beladel, Brahim [Djelfa Univ. (Algeria). Dept. of Physics

    2016-08-01

    Twenty two chemical elements were identified by Instrumental neutron activation analysis in Marrubium vulgare (Lamiaceae) a traditional medicine plant, used indigenously in Mediterranean basin to cure several diseases. The precision of the results was assessed by analyzing the certified reference material GBW 07605 (GSV-4) Tea leaves. Results showed that K was the dominant chemical element in studied plant (4.40%). The Ca and Fe mass fractions were also relatively high. However potential toxic elements in this Lamiaceae plant were within the safety limits suggested by WHO/FAO.

  5. Critical evaluation of the determination of zirconium and hafnium by instrumental and radiochemical neutron activation analysis

    International Nuclear Information System (INIS)

    Burger, Mario; Kraehenbuehl, Urs

    1991-01-01

    Neutron activation analysis (instrument or radiochemical) is suitable for the determination of zirconium and hafnium in samples of geochemical origin only when sufficient attention is paid to inter-fering nuclides. The size of the necessary correction for INAA depends on the composition of the sample; this problem is discussed. The radio-chemical technique which is recommended involves separation of the samples, precipitations and anion-exchange separation. Results are given for various standard reference materials and for meteorites. (author). 12 refs.; 1 fig.; 9 tabs

  6. Determination of phosphorus in wheat grass samples by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Kulkarni, S.D.; Rajurkar, N.S.; Acharya, R.; Nair, A.G.C.; Reddy, A.V.R.

    2005-01-01

    An instrumental neutron activation analysis (INAA) method using β-counting was used to determine phosphorus in wheat grass; grown in three different conditions. The phosphorus concentration was found to be in the range of 950-23000 mg/g in the samples grown in different conditions. The accuracy of the method was evaluated by determining phosphorus in three reference materials and the % deviations were within 10%. Reliability of the method was checked by following the half-life of the 32 P. (author)

  7. Determination of gold and silver in geological standard samples MGI by instrument neutron activation analysis

    International Nuclear Information System (INIS)

    Lu Huijiuan; Zhou; Yunlu

    1987-01-01

    Gold and silver in geological standard samples MGI were determined by instrument neutron activation analysis. The various interferences of nuclides were considered. Corrected factors of the geometry in different positions have been determined. Using the geological standard sample MGM and radiochemical separation neutron activation method as reference, the reliability of this method is proved. Gold content in samples is 0.4-0.009 g/t, silver content is 9-0.3 g/t. Standard deviation is less than 3.5%, the precision of the measurement is 4.8-11.6%

  8. Trace elements in cigarette tobacco by a method of instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Noordin Ibrahim

    1986-01-01

    A total of ten cigarette brands were investigated for determining the trace elemental concentrations in tobacco so as to assess their role in the induction of related diseases through smoking. A method instrumental Neutron Activation analysis was employed due to high sensitivity, speed and ability to analyse sample for a wide spectrum of elements simultaneously. A total of 18 elements were detected of which the majority are toxic elements. A full result and conclusion will be reported in the forthcoming paper. (A.J.)

  9. A hybrid instrument combining electronic and photonic tunnelling for surface analysis

    International Nuclear Information System (INIS)

    Pechou, R.; Ajustron, F.; Seine, G.; Coratger, R.; Maurel, C.; Beauvillain, J.

    2004-01-01

    A PSTM working in the collection mode and based on an STM probe-sample regulation scheme has been developed. This original hybrid instrument for surface analysis uses apertureless metal-coated chemically etched optical fibres. The use of an electronic tunnelling-based feedback loop significantly reduces tip-sample distance and leads to the collection of a high level near-field optical (NFO) signal. A simple amplified photodiode is thus used to perform optical signal acquisition and to draw electromagnetic field maps of sample surfaces. Experimental results on nanostructured gold surfaces are presented

  10. Mercury determination in dentist's hair and nails by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Mazzilli, B.; Munita, C.S.

    1986-01-01

    The mercury in scalp hair and fingernails of a group of dentists who usually handle with this toxic element in their profession is determined. The results were obtained by instrumental neutron activation analysis. The experimental procedure was based on the evaluation of the 197 Hg photopeak area, whose half life is 65h. After at a neutron fluxo of 5x10 12 n.cm -2 .sec -1 , the activity of the samples were measured by using a solid state Ge (Li) detector coupled to a 4.096 channel pulse height analyser. (M.A.C.) [pt

  11. Instrumental neutron activation analysis for the certification of biological reference materials

    International Nuclear Information System (INIS)

    Ambulkar, M.N.; Chutke, N.L.; Garg, A.N.

    1992-01-01

    A multielemental instrumental neutron activation analysis (INAA) method by short and long irradiation has been employed for the determination of 22 minor and trace constituents in two proposed Standard Reference Materials P-RBF and P-WBF from Institute of Radioecology and Applied Nuclear Techniques, Czechoslovakia. Also some biological standards such as Bowen's Kale, Cabbage leaves (Poland) including wheat and rice flour samples of local origin were analysed. It is suggested that INAA is an ideal method for the certification of reference materials of biological matrices. (author). 7 refs., 1 tab

  12. Instrument for Solvent Extraction and Analysis (ISEE) of Organics from Regolith Simulant Using Supercritical Fluid Extraction and Chromatography

    Science.gov (United States)

    Franco, Carolina; Hintze, Paul E.

    2017-01-01

    ISEE is an instrument with the potential to perform extractions from regolith found on the surface of asteroids and planets, followed by characterization and quantitation of the extracts using supercritical fluid extraction (SFE) and chromatography (SFC). SFE is a developed technique proven to extract a wide range of organic compounds. SFC is similar to High Performance Liquid Chromatography (HPLC) but has the advantage of performing chiral separations without needing to derivatize the chiral compounds. CO2 will be the solvent for both stages as it is readily available in the Mars atmosphere. ISEE will capture CO2 from the environment, and use it for SFE and SFC. If successful, this would allow ISEE to perform analysis of organic compounds without using consumables. This paper will present results on a preliminary, proof-of-principle effort to use SFE and SFC to extract and analyze lunar regolith simulant spiked with organic compounds representing a range of organics that ISEE would expect to characterize. An optimization of variables for the extraction of the organics from the spiked regolith was successfully developed, using 138 bar pressure and 40 C temperature. The extraction flow rate was optimized at 2% SLPM with 30% methanol modifier. The extractions were successful with a value of 77.3+/- 0.9% of organics extracted. However, the recovery of organics after the extraction was very low with only 48.5+/-14.2%. Moreover, three columns were selected to analyze multiple samples at a time; two of them are Viridis HSS C18 SB and Torus DIOL, and the third column, specific for chiral separations, has not yet been selected yet.

  13. Determination of uranium and thorium in rock samples from Harargaj Anticline by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Rahman, M.; Molla, N.I.; Sharif, A.K.M.; Basunia, S.; Islam, S.; Miah, R.U.; Hossain, S.M.; Chowdhury, M.I.; Bhuiyan, A.D.; Stegnar, P.

    1993-01-01

    Uranium and thorium were determined in geological materials such as radioactive rock samples collected from the Harargaj Anticline in Moulavi Bazar. The pure instrumental neutron activation analysis (INAA) technique was used in qualitative and quantitative analysis of the rock samples for U and Th. The samples were properly prepared together with their standards and simultaneously irradiated in a neutron flux of the order of 10 12 n*cm -2 *s -1 using the TRIGA MARK II research reactor facility at the AERE, Savar, Dhaka. After activation the samples were subjected to γ-ray spectrometry using a high purity germanium detection system. As a result of the analysis, U and Th could be determined. The data are consistent with the values reported by the ground radiometric survey group for some of the samples. (author) 7 refs.; 1 fig.; 2 tabs

  14. Siderophile element concentrations in magnetic spherules from deep sea sediments revealed by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Nogami, Ken-ichi; Shimamura, Tadashi; Tazawa, Yuji; Yamakoshi, Kazuo.

    1980-01-01

    For the purpose of deciding the extraterrestrial origin of the magnetic spherules found in deep sea sediments, the siderophile elements Co, Ni, Ir and/or Au etc., were measured by instrumental neutron activation analysis. Spherules were collected from red clay samples which were dredged from Mid Pacific Ocean. Only spherules which had smooth surfaces and relatively high specific gravities were chosen for analysis. Existence of Co, Ni and Ir in most spherules suggests the possibility of an extraterrestrial origin for these spherules. It is not clear whether these spherules are droplets ablated from iron meteorites entering into the Earth's atmosphere or they are cosmic iron grains themselves. X-ray diffraction analysis suggested that these spherules are the products of rapid cooling materials. (author)

  15. The geographical origin and chemical composition in phellinus mushrooms measured by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Lim, J.M.; Sun, G.M.; Moon, J.H.; Chung, Y.S.; Lee, J.H.; Kim, K.H.

    2012-01-01

    In order to expand the utilization of phellinus mushrooms as a dietary supplement, we attempted to evaluate the chemical composition by measuring its inorganic elemental content with the aid of instrumental neutron activation analysis (INAA). Twenty seven phellinus mushrooms samples were collected from Korea, Cambodia, and Vietnam. A total of 28 elements were analyzed in the phellinus mushroom samples using the INAA. The concentrations of Ca, K, and Mg are much higher than those of other elements in phellinus mushroom samples. The sum of determined elemental concentration in Cambodia samples was about 2-6 times higher than those in Korea and Vietnam samples, respectively. Based on our measurement data, we attempted to discriminate the geographical origin using principal components analysis (PCA) and linear discriminant analysis (LDA). The geographical origins of all samples were clearly classified with correct classification rate of 100%. (author)

  16. Determination of selenium and zinc in rat plasma by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Munoz A, Luis.

    1997-01-01

    To evaluate the effects on the thyroid function when simple or multiple zinc, selenium and iodine deficiency are induced, research was carried out in laboratory animals. For simultaneously determining the Zn and Se concentration in rat plasma, an instrumental neutron activation analysis technique was applied. A clean laboratory, was used for the preparation of samples. High purity materials were used for sample collection and storage. Irradiation, decay and counting parameters were optimized to obtain the best sensitivity, accuracy and precision analysis. The Zn and Se concentrations were determined from the peak area of gamma-rays of 1115 and 265 KeV respectively. The analytical methodology used was validated with standard reference materials. The procedure used for the analysis, including the phases of collection, treatment of the samples and analytical determination was considered suitable for the study of trace elements in biological samples, especially plasma. (author) [es

  17. Development and preliminary validation of Brace Questionnaire (BrQ: a new instrument for measuring quality of life of brace treated scoliotics

    Directory of Open Access Journals (Sweden)

    Gkoltsiou Konstantina

    2006-05-01

    Full Text Available Abstract Background The quality of life among children with idiopathic scoliosis during their adolescence has been reported to be affected by the brace itself. However, a controversy exists whether brace treated scoliotics experience a poor quality of life, thus there is a need for the development of a brace-oriented instrument, as the now-existing questionnaires that are commonly used, such as the SRS -22, take into consideration the effects of both the conservative and the surgical treatment on quality of life of scoliotic children. The aim of the present study is to assess the validity and reliability of Brace Questionnaire (BrQ, a new instrument for measuring quality of life of scoliotic adolescents who are treated conservatively with a brace. Material-method Methodology of development involved literature review, patient and health care professionals' in-depth interviews and content validity analysis on patients. A validation study was performed on 28 brace treated scoliotic children aged between 9 and 18 years old. BrQ was assessed for the following psychometric properties: item convergent validity, floor and ceiling effects, internal consistency reliability, clinical validity and responsiveness to change. Results BrQ is self administrated and developmentally appropriate for ages 9 to 18 years old and is consisted of 34 Likert-scale items associated with eight domains: general health perception, physical functioning, emotional functioning, self esteem and aesthetics, vitality, school activity, bodily pain and social functioning of scoliotic children treated conservatively with a brace. The subscales of these eight dimensions can be combined to produce a total score. Higher scores mean a better quality of life. An item convergent validity ≥ 0.40 was satisfied by all items in the present study. A satisfactory internal consistency reliability for the BrQ was recorded (Cronbach's alpha coefficient was 0.82. There were no floor or ceiling

  18. The purification, crystallization and preliminary X-ray diffraction analysis of dihydrodipicolinate synthase from Clostridium botulinum

    International Nuclear Information System (INIS)

    Dobson, Renwick C. J.; Atkinson, Sarah C.; Gorman, Michael A.; Newman, Janet M.; Parker, Michael W.; Perugini, Matthew A.

    2008-01-01

    Dihydrodipicolinate synthase (DHDPS), an enzyme in the lysine-biosynthetic pathway, is a promising target for antibiotic development against pathogenic bacteria. Here, the expression, purification, crystallization and preliminary diffraction analysis of DHDPS from C. botulinum are reported. In recent years, dihydrodipicolinate synthase (DHDPS; EC 4.2.1.52) has received considerable attention from both mechanistic and structural viewpoints. This enzyme, which is part of the diaminopimelate pathway leading to lysine, couples (S)-aspartate-β-semialdehyde with pyruvate via a Schiff base to a conserved active-site lysine. In this paper, the expression, purification, crystallization and preliminary X-ray diffraction analysis of DHDPS from Clostridium botulinum, an important bacterial pathogen, are presented. The enzyme was crystallized in a number of forms, predominantly using PEG precipitants, with the best crystal diffracting to beyond 1.9 Å resolution and displaying P4 2 2 1 2 symmetry. The unit-cell parameters were a = b = 92.9, c = 60.4 Å. The crystal volume per protein weight (V M ) was 2.07 Å 3 Da −1 , with an estimated solvent content of 41%. The structure of the enzyme will help guide the design of novel therapeutics against the C. botulinum pathogen

  19. A Preliminary Analysis of Reactor Performance Test (LOEP) for a Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyeonil; Park, Su-Ki [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The final phase of commissioning is reactor performance test, which is to prove the integrated performance and safety of the research reactor at full power with fuel loaded such as neutron power calibration, Control Absorber Rod/Second Shutdown Rod drop time, InC function test, Criticality, Rod worth, Core heat removal with natural mechanism, and so forth. The last test will be safety-related one to assure the result of the safety analysis of the research reactor is marginal enough to be sure about the nuclear safety by showing the reactor satisfies the acceptance criteria of the safety functions such as for reactivity control, maintenance of auxiliaries, reactor pool water inventory control, core heat removal, and confinement isolation. After all, the fuel integrity will be ensured by verifying there is no meaningful change in the radiation levels. To confirm the performance of safety equipment, loss of normal electric power (LOEP), possibly categorized as Anticipated Operational Occurrence (AOO), is selected as a key experiment to figure out how safe the research reactor is before turning over the research reactor to the owner. This paper presents a preliminary analysis of the reactor performance test (LOEP) for a research reactor. The results showed how different the transient between conservative estimate and best estimate will look. Preliminary analyses have shown all probable thermal-hydraulic transient behavior of importance as to opening of flap valve, minimum critical heat flux ratio, the change of flow direction, and important values of thermal-hydraulic parameters.

  20. Crystallization and preliminary X-ray diffraction analysis of diaminopimelate epimerase from Escherichia coli

    International Nuclear Information System (INIS)

    Hor, Lilian; Dobson, Renwick C. J.; Dogovski, Con; Hutton, Craig A.; Perugini, Matthew A.

    2009-01-01

    Diaminopimelate (DAP) epimerase, an enzyme in the lysine-biosynthetic pathway, is a promising target for antibiotic development against pathogenic bacteria. Here, the cloning, expression, purification, crystallization and preliminary diffraction analysis of DAP epimerase from E. coli are reported. Diaminopimelate (DAP) epimerase (EC 5.1.1.7) catalyzes the penultimate step of lysine biosynthesis in bacteria and plants, converting l,l-diaminopimelate to meso-diaminopimelate. Here, the cloning, expression, purification, crystallization and preliminary X-ray diffraction analysis of DAP epimerase from Escherichia coli are presented. Crystals were obtained in space group P4 1 2 1 2 and diffracted to 2.0 Å resolution, with unit-cell parameters a = b = 89.4, c = 179.6 Å. Molecular replacement was conducted using Bacillus anthracis DAP epimerase as a search model and showed the presence of two molecules in the asymmetric unit, with an initial R free of 0.456 and R work of 0.416