WorldWideScience

Sample records for instrumentation initiative describes

  1. 7-GeV Advanced Photon Source Instrumentation Initiative conceptual design report

    International Nuclear Information System (INIS)

    1992-12-01

    In this APS Instrumentation Initiative, 2.5-m-long and 5-m-long insertion-device x-ray sources will be built on 9 straight sections of the APS storage ring, and an additional 9 bending-magnet sources will also be put in use. The front ends for these 18 x-ray sources will be built to contain and safeguard access to these bright x-ray beams. In addition, funds will be provided to build state-of-the-art insertion-device beamlines to meet scientific and technological research demands well into the next century. This new initiative will also include four user laboratory modules and a special laboratory designed to meet the x-ray imaging research needs of the users. The Conceptual Design Report (CDR) for the APS Instrumentation Initiative describes the scope of all the above technical and conventional construction and provides a detailed cost and schedule for these activities. According to these plans, this new initiative begins in FY 1994 and ends in FY 1998. The document also describes the preconstruction R ampersand D plans for the Instrumentation Initiative activities and provides the cost estimates for the required R ampersand D

  2. Aquarius: The Instrument and Initial Results

    Science.gov (United States)

    Vine, David M Le; Lagerloef, G.S.E.; Ruf, C.; Wentz, F.; Yueh, S.; Piepmeier, J.; Lindstrom, E.; Dinnat, E.

    2012-01-01

    Aquarius was launched on June 10, 2011 aboard the Aquarius/SAC-D observatory and the instrument has been operating continuously since the initial turned-on was completed on August 25. The initial observed antenna temperatures were close to predicted and the first salinity map was released in September. In order to map the ocean salinity field, Aquarius includes several special features such as the inclusion of a scatterometer to provide a roughness correction, measurement of the third Stokes parameter to correct for Faraday rotation, and fast sampling to mitigate the effects of RFI. This paper provides an overview of the instrument and an example of initial results. Details are covered in subsequent papers in the session on Aquarius

  3. The Open Geospatial Consortium PUCK Standard: Building Sensor Networks with Self-Describing Instruments

    Science.gov (United States)

    O'Reilly, T. C.; Broering, A.; del Rio, J.; Headley, K. L.; Toma, D.; Bermudez, L. E.; Edgington, D.; Fredericks, J.; Manuel, A.

    2012-12-01

    Sensor technology is rapidly advancing, enabling smaller and cheaper instruments to monitor Earth's environment. It is expected that many more kinds and quantities of networked environmental sensors will be deployed in coming years. Knowledge of each instrument's command protocol is required to operate and acquire data from the network. Making sense of these data streams to create an integrated picture of environmental conditions requires that each instrument's data and metadata be accurately processed and that "suspect" data be flagged. Use of standards to operate an instrument and retrieve and describe its data generally simplifies instrument software development, integration, operation and data processing. The Open Geospatial Consortium (OGC) PUCK protocol enables instruments that describe themselves in a standard way. OGC PUCK defines a small "data sheet" that describes key instrument characteristics, and a standard protocol to retrieve the data sheet from the device itself. Data sheet fields include a universal serial number that is unique across all PUCK-compliant instruments. Other fields identify the instrument manufacturer and model. In addition to the data sheet, the instrument may also provide a "PUCK payload" which can contain additional descriptive information (e.g. a SensorML document or IEEE 1451 TEDS), as well as actual instrument "driver" code. Computers on the sensor network can use PUCK protocol to retrieve this information from installed instruments and utilize it appropriately, e.g. to automatically identify, configure and operate the instruments, and acquire and process their data. The protocol is defined for instruments with an RS232 or Ethernet interface. OGC members recently voted to adopt PUCK as a component of the OGC's Sensor Web Enablement (SWE) standards. The protocol is also supported by a consortium of hydrographic instrument manufacturers and has been implemented by several of them (https://sites.google.com/site/soscsite/). Thus far

  4. Rotary mode system initial instrument calibration

    International Nuclear Information System (INIS)

    Johns, B.R.

    1994-01-01

    The attached report contains the vendor calibration procedures used for the initial instrument calibration of the rotary core sampling equipment. The procedures are from approved vendor information files

  5. Instrumented Pipeline Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Thomas Piro; Michael Ream

    2010-07-31

    This report summarizes technical progress achieved during the cooperative agreement between Concurrent Technologies Corporation (CTC) and U.S. Department of Energy to address the need for a for low-cost monitoring and inspection sensor system as identified in the Department of Energy (DOE) National Gas Infrastructure Research & Development (R&D) Delivery Reliability Program Roadmap.. The Instrumented Pipeline Initiative (IPI) achieved the objective by researching technologies for the monitoring of pipeline delivery integrity, through a ubiquitous network of sensors and controllers to detect and diagnose incipient defects, leaks, and failures. This report is organized by tasks as detailed in the Statement of Project Objectives (SOPO). The sections all state the objective and approach before detailing results of work.

  6. Utilisation and performance of sodium instrumentation during start-up and initial operation of Phenix

    International Nuclear Information System (INIS)

    Lions, N.; Buis, H.; Baron, J.; Fournier, C.; Gourdon, J.

    1976-01-01

    The main process-instruments on the Phenix reactor are presented with the exception of the FFDL System and of the hydrogen-detector which are described in other papers. The results obtained during reactor start-up and during initial operation of the nuclear power-station are given [fr

  7. A mathematical model for describing the mechanical behaviour of root canal instruments.

    Science.gov (United States)

    Zhang, E W; Cheung, G S P; Zheng, Y F

    2011-01-01

    The purpose of this study was to establish a general mathematical model for describing the mechanical behaviour of root canal instruments by combining a theoretical analytical approach with a numerical finite-element method. Mathematical formulas representing the longitudinal (taper, helical angle and pitch) and cross-sectional configurations and area, the bending and torsional inertia, the curvature of the boundary point and the (geometry of) loading condition were derived. Torsional and bending stresses and the resultant deformation were expressed mathematically as a function of these geometric parameters, modulus of elasticity of the material and the applied load. As illustrations, three brands of NiTi endodontic files of different cross-sectional configurations (ProTaper, Hero 642, and Mani NRT) were analysed under pure torsion and pure bending situation by entering the model into a finite-element analysis package (ANSYS). Numerical results confirmed that mathematical models were a feasible method to analyse the mechanical properties and predict the stress and deformation for root canal instruments during root canal preparation. Mathematical and numerical model can be a suitable way to examine mechanical behaviours as a criterion of the instrument design and to predict the stress and strain experienced by the endodontic instruments during root canal preparation. © 2010 International Endodontic Journal.

  8. Design of and initial results from a Highly Instrumented Reactor for Atmospheric Chemistry (HIRAC

    Directory of Open Access Journals (Sweden)

    D. R. Glowacki

    2007-10-01

    Full Text Available The design of a Highly Instrumented Reactor for Atmospheric Chemistry (HIRAC is described and initial results obtained from HIRAC are presented. The ability of HIRAC to perform in-situ laser-induced fluorescence detection of OH and HO2 radicals with the Fluorescence Assay by Gas Expansion (FAGE technique establishes it as internationally unique for a chamber of its size and pressure/temperature variable capabilities. In addition to the FAGE technique, HIRAC features a suite of analytical instrumentation, including: a multipass FTIR system; a conventional gas chromatography (GC instrument and a GC instrument for formaldehyde detection; NO/NO2, CO, O3, and H2O vapour analysers. Ray tracing simulations and NO2 actinometry have been utilized to develop a detailed model of the radiation field within HIRAC. Comparisons between the analysers and the FTIR coupled to HIRAC have been performed, and HIRAC has also been used to investigate pressure dependent kinetics of the chlorine atom reaction with ethene and the reaction of O3 and t-2-butene. The results obtained are in good agreement with literature recommendations and Master Chemical Mechanism predictions. HIRAC thereby offers a highly instrumented platform with the potential for: (1 high precision kinetics investigations over a range of atmospheric conditions; (2 detailed mechanism development, significantly enhanced according to its capability for measuring radicals; and (3 field instrument intercomparison, calibration, development, and investigations of instrument response at a range of atmospheric conditions.

  9. [Development and validation of an instrument for initial nursing assessment].

    Science.gov (United States)

    Fernández-Sola, Cayetano; Granero-Molina, José; Mollinedo-Mallea, Judith; de Gonzales, María Hilda Peredo; Aguilera-Manrique, Gabriel; Ponce, Mara Luna

    2012-12-01

    The objective of this study, conducted in Bolivia from April to July of 2008, is the design and validation of an initial nursing assessment instrument to be used in clinical and educational environments in Santa Cruz (Bolivia). Twelve Bolivian nurses participated; both document analysis as well as consensus techniques were used to determine the categories and criteria to be assessed. Categories included in the nursing assessment instrument are a physical assessment and the eleven Gordon's Functional Health Patterns. The nursing assessment instrument stands out as being concise, easy to complete and utilizing a nursing approach. It does not include items for advanced nursing assessment. However, it incorporates items regarding lifestyle and the patient's autonomy. The nursing assessment instrument contributes to improving the quality of clinical records, supports the nursing diagnosis and implementation of the nursing process, promotes the nurse's role and helps to standardize practice.

  10. Diverse Portfolio of Scientific Instrumentation Initiatives of the Deep Carbon Observatory

    Science.gov (United States)

    Schiffries, Craig; Hazen, Robert; Hemley, Russell; Mangum, Andrea

    2016-04-01

    Advances in scientific instrumentation are important drivers of scientific discovery. The Deep Carbon Observatory (DCO) supports a diverse portfolio of scientific instrumentation initiatives worldwide as part of its ten-year quest to achieve a transformational understanding of the quantities, movements, origins, and forms of Earth's deep carbon. Substantial progress has been made in the development of a wide range of instruments, including: • Quantum cascade laser-infrared absorption spectrometer for clumped methane isotope thermometry (Shuhei Ono) • Large-radius high-mass-resolution multiple-collector isotope ratio mass spectrometer for analysis of rare isotopologues of methane and other gases (Edward Young, Douglas Rumble) • Volcanic field deployment of the laser isotope ratio-meter (Damien Weidmann) • Novel large-volume diamond anvil cell for neutron scattering (Malcolm Guthrie, Reinhard Boehler) • Novel synchrotron x-ray probes for deep carbon (Wendy Mao) • Ultrafast laser instrument for in situ measurements of elastic, electronic, and transport properties of carbon-bearing fluids and crystalline materials (Alexander Goncharov) • Combined instrument for molecular imaging in geochemistry (Andrew Steele) • Pressurized Underwater Sample Handler (Isabelle Daniel, Karyn Rogers) These and other DCO instrumentation projects are highly leveraged investments involving a large number of sponsors, partners, and collaborators.

  11. Instrument validation system of general application

    International Nuclear Information System (INIS)

    Filshtein, E.L.

    1990-01-01

    This paper describes the Instrument Validation System (IVS) as a software system which has the capability of evaluating the performance of a set of functionally related instrument channels to identify failed instruments and to quantify instrument drift. Under funding from Combustion Engineering (C-E), the IVS has been developed to the extent that a computer program exists whose use has been demonstrated. The initial development work shows promise for success and for wide application, not only to power plants, but also to industrial manufacturing and process control. Applications in the aerospace and military sector are also likely

  12. Invited Article: First Flight in Space of a Wide-field-of-view Soft X-Ray Imager Using Lobster-Eye Optics: Instrument Description and Initial Flight Results

    Science.gov (United States)

    Collier, Michael; Porter, F. Scott; Sibeck, David G.; Carter, Jenny A.; Chiao, Meng P.; Chomay, Dennis J.; Cravens, Thomas E.; Galeazzi, Massiniliano; Keller, John; Koutroumpa, Dimitra

    2015-01-01

    We describe the development, launch into space, and initial results from a prototype wide eld-of-view (FOV) soft X-ray imager that employs Lobster-eye optics and targets heliophysics, planetary, and astrophysics science. The Sheath Transport Observer for the Redistribution of Mass (STORM) is the rst instrument using this type of optics launched into space and provides proof-of-concept for future ight instruments capable of imaging structures such as the terrestrial cusp, the entire dayside magnetosheath from outside the magnetosphere, comets, the moon, and the solar wind interaction with planetary bodies like Venus and Mars.

  13. Invited Article: First flight in space of a wide-field-of-view soft x-ray imager using lobster-eye optics: Instrument description and initial flight results.

    Science.gov (United States)

    Collier, Michael R; Porter, F Scott; Sibeck, David G; Carter, Jenny A; Chiao, Meng P; Chornay, Dennis J; Cravens, Thomas E; Galeazzi, Massimiliano; Keller, John W; Koutroumpa, Dimitra; Kujawski, Joseph; Kuntz, Kip; Read, Andy M; Robertson, Ina P; Sembay, Steve; Snowden, Steven L; Thomas, Nicholas; Uprety, Youaraj; Walsh, Brian M

    2015-07-01

    We describe the development, launch into space, and initial results from a prototype wide field-of-view soft X-ray imager that employs lobster-eye optics and targets heliophysics, planetary, and astrophysics science. The sheath transport observer for the redistribution of mass is the first instrument using this type of optics launched into space and provides proof-of-concept for future flight instruments capable of imaging structures such as the terrestrial cusp, the entire dayside magnetosheath from outside the magnetosphere, comets, the Moon, and the solar wind interaction with planetary bodies like Venus and Mars [Kuntz et al., Astrophys. J. (in press)].

  14. From Qualitative Data to Instrument Development: The Women's Breast Conflict Scale

    Science.gov (United States)

    Thomas, Eileen

    2011-01-01

    The purpose of this article is to describe the initial development of the Women's Breast Conflict Scale, a predictive instrument designed to identify women who may be least likely to follow recommended mammography screening guidelines. This new instrument incorporates self/body image, teasing, family norms and values, and societal/media…

  15. Using XML and Java for Astronomical Instrumentation Control

    Science.gov (United States)

    Ames, Troy; Koons, Lisa; Sall, Ken; Warsaw, Craig

    2000-01-01

    Traditionally, instrument command and control systems have been highly specialized, consisting mostly of custom code that is difficult to develop, maintain, and extend. Such solutions are initially very costly and are inflexible to subsequent engineering change requests, increasing software maintenance costs. Instrument description is too tightly coupled with details of implementation. NASA Goddard Space Flight Center is developing a general and highly extensible framework that applies to any kind of instrument that can be controlled by a computer. The software architecture combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML), a human readable and machine understandable way to describe structured data. A key aspect of the object-oriented architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). ]ML is used to describe graphical user interfaces to control and monitor the instrument, command sets and command formats, data streams, and communication mechanisms. Although the current effort is targeted for the High-resolution Airborne Wideband Camera, a first-light instrument of the Stratospheric Observatory for Infrared Astronomy, the framework is designed to be generic and extensible so that it can be applied to any instrument.

  16. Evaluation of a draft standard on performance specifications for health physics instrumentation. Initial results for radiological tests

    International Nuclear Information System (INIS)

    Swinth, K.L.; Kenoyer, J.L.; Mileham, A.P.; Kathren, R.L.; Selby, J.M.

    1983-06-01

    The draft ANSI standard N42.17D2 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. The primary objective of the project is the evaluation of the applicability and practicality of the proposed standard through testing of a cross-section of currently available commercial instruments to determine how well they conform to the standard. The standard is being tested against instruments such as ionization chambers, G.M. detectors, alpha survey meters, and neutron dose equivalent survey meters. This paper presents results of the preliminary radiological performance tests on ionization chambers and G.M. detectors. This includes both the data generated during the tests and a discussion of procedures developed to perform the testing. Results are reported for response time, accuracy, precision, radiation overloads, and angular dependence. In addition, results are reported for parameters that affect instrument performance including battery lifetime, geotropism and stability. Initial test indicates that some of the instruments will not meet the criteria specified in ANSI N42.17D2. Results cover approximately 40 instruments that have been obtained by direct purchase, by loan from instrument vendors or by loan from others including DOE licensees

  17. UAVSAR Program: Initial Results from New Instrument Capabilities

    Science.gov (United States)

    Lou, Yunling; Hensley, Scott; Moghaddam, Mahta; Moller, Delwyn; Chapin, Elaine; Chau, Alexandra; Clark, Duane; Hawkins, Brian; Jones, Cathleen; Marks, Phillip; hide

    2013-01-01

    UAVSAR is an imaging radar instrument suite that serves as NASA's airborne facility instrument to acquire scientific data for Principal Investigators as well as a radar test-bed for new radar observation techniques and radar technology demonstration. Since commencing operational science observations in January 2009, the compact, reconfigurable, pod-based radar has been acquiring L-band fully polarimetric SAR (POLSAR) data with repeat-pass interferometric (RPI) observations underneath NASA Dryden's Gulfstream-III jet to provide measurements for science investigations in solid earth and cryospheric studies, vegetation mapping and land use classification, archaeological research, soil moisture mapping, geology and cold land processes. In the past year, we have made significant upgrades to add new instrument capabilities and new platform options to accommodate the increasing demand for UAVSAR to support scientific campaigns to measure subsurface soil moisture, acquire data in the polar regions, and for algorithm development, verification, and cross-calibration with other airborne/spaceborne instruments.

  18. [Support of the nursing process through electronic nursing documentation systems (UEPD) – Initial validation of an instrument].

    Science.gov (United States)

    Hediger, Hannele; Müller-Staub, Maria; Petry, Heidi

    2016-01-01

    Electronic nursing documentation systems, with standardized nursing terminology, are IT-based systems for recording the nursing processes. These systems have the potential to improve the documentation of the nursing process and to support nurses in care delivery. This article describes the development and initial validation of an instrument (known by its German acronym UEPD) to measure the subjectively-perceived benefits of an electronic nursing documentation system in care delivery. The validity of the UEPD was examined by means of an evaluation study carried out in an acute care hospital (n = 94 nurses) in German-speaking Switzerland. Construct validity was analyzed by principal components analysis. Initial references of validity of the UEPD could be verified. The analysis showed a stable four factor model (FS = 0.89) scoring in 25 items. All factors loaded ≥ 0.50 and the scales demonstrated high internal consistency (Cronbach's α = 0.73 – 0.90). Principal component analysis revealed four dimensions of support: establishing nursing diagnosis and goals; recording a case history/an assessment and documenting the nursing process; implementation and evaluation as well as information exchange. Further testing with larger control samples and with different electronic documentation systems are needed. Another potential direction would be to employ the UEPD in a comparison of various electronic documentation systems.

  19. An overview of therapeutic initiatives when working with persons suffering from dementia

    DEFF Research Database (Denmark)

    Ridder, Hanne Mette Ochsner

    2005-01-01

    In this chapter I will describe how music is used in a wide range of initiatives with persons suffering from dementia. There are various ways of implementing music: in groups or individually, by singing songs, listening to music, dancing, or improvising on instruments. I hope to give an introduct......In this chapter I will describe how music is used in a wide range of initiatives with persons suffering from dementia. There are various ways of implementing music: in groups or individually, by singing songs, listening to music, dancing, or improvising on instruments. I hope to give...

  20. NASA Instrument Cost/Schedule Model

    Science.gov (United States)

    Habib-Agahi, Hamid; Mrozinski, Joe; Fox, George

    2011-01-01

    NASA's Office of Independent Program and Cost Evaluation (IPCE) has established a number of initiatives to improve its cost and schedule estimating capabilities. 12One of these initiatives has resulted in the JPL developed NASA Instrument Cost Model. NICM is a cost and schedule estimator that contains: A system level cost estimation tool; a subsystem level cost estimation tool; a database of cost and technical parameters of over 140 previously flown remote sensing and in-situ instruments; a schedule estimator; a set of rules to estimate cost and schedule by life cycle phases (B/C/D); and a novel tool for developing joint probability distributions for cost and schedule risk (Joint Confidence Level (JCL)). This paper describes the development and use of NICM, including the data normalization processes, data mining methods (cluster analysis, principal components analysis, regression analysis and bootstrap cross validation), the estimating equations themselves and a demonstration of the NICM tool suite.

  1. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. This report describes an inspector-instrument interface design which allows communication of procedures, responses, and results between the instrument and user. The interface has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  2. Incidence of apical crack initiation and propagation during the removal of root canal filling material with ProTaper and Mtwo rotary nickel-titanium retreatment instruments and hand files.

    Science.gov (United States)

    Topçuoğlu, Hüseyin Sinan; Düzgün, Salih; Kesim, Bertan; Tuncay, Oznur

    2014-07-01

    The aim of this study was to determine the incidence of crack initiation and propagation in apical root dentin after retreatment procedures performed by using 2 rotary retreatment systems and hand files with additional instrumentation. Eighty extracted mandibular premolars with single canals were selected. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the control group, and no preparation was performed. The remaining 60 teeth were prepared to size 35 with rotary files and filled with gutta-percha and AH Plus sealer. Specimens were then divided into 3 groups (n = 20), and retreatment procedures were performed with the following devices and techniques: ProTaper Universal retreatment files, Mtwo retreatment files, and hand files. After retreatment, the additional instrumentation was performed by using size 40 ProTaper, Mtwo, and hand files. Digital images of the apical root surface were recorded before preparation, after instrumentation, after filling, after retreatment, and after additional instrumentation. The images were then inspected for the presence of any new apical cracks and propagation. Data were analyzed with the logistic regression and Fisher exact tests. All experimental groups caused crack initiation and propagation after use of retreatment instruments. The ProTaper and Mtwo retreatment groups caused greater crack initiation and propagation than the hand instrument group (P ProTaper and Mtwo instruments after the use of retreatment instruments caused crack initiation and propagation, whereas hand files caused neither crack initiation nor propagation (P < .05). This study showed that retreatment procedures and additional instrumentation after the use of retreatment files may cause crack initiation and propagation in apical dentin. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. The Community College Survey of Men: An Initial Validation of the Instrument's Non-Cognitive Outcomes Construct

    Science.gov (United States)

    Wood, J. \\Luke; Harris, Frank, III.

    2013-01-01

    The purpose of this manuscript is to discuss the utility of the Community College Survey of Men (CCSM[c]), an instrument designed to examine predictors of student success for men in community colleges. The authors highlight initial validation results from a recent pilot of the CCSM[c], with a focus on the non-cognitive outcomes construct employed…

  4. Initial development and psychometric testing of an instrument to measure the quality of children's end-of-life care.

    Science.gov (United States)

    Widger, Kimberley; Tourangeau, Ann E; Steele, Rose; Streiner, David L

    2015-01-01

    The field of pediatric palliative care is hindered by the lack of a well-defined, reliable, and valid method for measuring the quality of end-of-life care. The study purpose was to develop and test an instrument to measure mothers' perspectives on the quality of care received before, at the time of, and following a child's death. In Phase 1, key components of quality end-of-life care for children were synthesized through a comprehensive review of research literature. These key components were validated in Phase 2 and then extended through focus groups with bereaved parents. In Phase 3, items were developed to assess structures, processes, and outcomes of quality end-of-life care then tested for content and face validity with health professionals. Cognitive testing was conducted through interviews with bereaved parents. In Phase 4, bereaved mothers were recruited through 10 children's hospitals/hospices in Canada to complete the instrument, and psychometric testing was conducted. Following review of 67 manuscripts and 3 focus groups with 10 parents, 141 items were initially developed. The overall content validity index for these items was 0.84 as rated by 7 health professionals. Based on feedback from health professionals and cognitive testing with 6 parents, a 144-item instrument was finalized for further testing. In Phase 4, 128 mothers completed the instrument, 31 of whom completed it twice. Test-retest reliability, internal consistency, and construct validity were demonstrated for six subscales: Connect With Families, Involve Parents, Share Information With Parents, Share Information Among Health Professionals, Support Parents, and Provide Care at Death. Additional items with content validity were grouped in four domains: Support the Child, Support Siblings, Provide Bereavement Follow-up, and Structures of Care. Forty-eight items were deleted through psychometric testing, leaving a 95-item instrument. There is good initial evidence for the reliability and

  5. Health physics instrument manual

    International Nuclear Information System (INIS)

    Gupton, E.D.

    1978-08-01

    The purpose of this manual is to provide apprentice health physics surveyors and other operating groups not directly concerned with radiation detection instruments a working knowledge of the radiation detection and measuring instruments in use at the Laboratory. The characteristics and applications of the instruments are given. Portable instruments, stationary instruments, personnel monitoring instruments, sample counters, and miscellaneous instruments are described. Also, information sheets on calibration sources, procedures, and devices are included. Gamma sources, beta sources, alpha sources, neutron sources, special sources, a gamma calibration device for badge dosimeters, and a calibration device for ionization chambers are described

  6. An instrumentation and control philosophy for high-level nuclear waste processing facilities

    International Nuclear Information System (INIS)

    Weigle, D.H.

    1990-01-01

    The purpose of this paper is to present an instrumentation and control philosophy which may be applied to high-level nuclear waste processing facilities. This philosophy describes the recommended criteria for automatic/manual control, remote/local control, remote/local display, diagnostic instrumentation, interlocks, alarm levels, and redundancy. Due to the hazardous nature of the process constituents of a high-level nuclear waste processing facility, it is imperative that safety and control features required for accident-free operation and maintenance be incorporated. A well-instrumented and controlled process, while initially more expensive in capital and design costs, is generally safer and less expensive to operate. When the long term cost savings of a well designed process is coupled with the high savings enjoyed by accident avoidance, the benefits far outweigh the initial capital and design costs

  7. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  8. Drugs as instruments: Describing and testing a behavioral approach to the study of neuroenhancement

    Directory of Open Access Journals (Sweden)

    Ralf Brand

    2016-08-01

    Full Text Available Neuroenhancement (NE is the non-medical use of psychoactive substances to produce a subjective enhancement in psychological functioning and experience. So far empirical investigations of individuals’ motivation for NE however have been hampered by the lack of theoretical foundation. This study aimed to apply drug instrumentalization theory to user motivation for NE. We argue that NE should be defined and analyzed from a behavioral perspective rather than in terms of the characteristics of substances used for NE. In the empirical study we explored user behavior by analyzing relationships between drug options (use over-the-counter products, prescription drugs, illicit drugs and postulated drug instrumentalization goals (e.g. improved cognitive performance, counteracting fatigue, improved social interaction. Questionnaire data from 1,438 university students were subjected to exploratory and confirmatory factor analysis to address the question of whether analysis of drug instrumentalization should be based on the assumption that users are aiming to achieve a certain goal and choose their drug accordingly or whether NE behavior is more strongly rooted in a decision to try or use a certain drug option. We used factor mixture modeling to explore whether users could be separated into qualitatively different groups defined by a shared ‘goal × drug option’ configuration. Our results indicate, first, that individuals’ decisions about NE are eventually based on personal attitude to drug options (e.g. willingness to use an over-the-counter product but not to abuse prescription drugs rather than motivated by desire to achieve a specific goal (e.g. fighting tiredness for which different drug options might be tried. Second, data analyses suggested two qualitatively different classes of users. Both predominantly used over-the-counter products, but ‘neuroenhancers’ might be characterized by a higher propensity to instrumentalize over

  9. Direct Measurement of Initial Enrichment, Burn-up and Cooling Time of Spent Fuel Assembly with a Differential Die-Away Technique Based Instrument

    International Nuclear Information System (INIS)

    Henzl, Vladimir; Swinhoe, Martyn T.; Tobin, Stephen J.

    2012-01-01

    An outline of this presentation of what a Differential Die-Away (DDA) instrument can do are: (1) Principle of operation of DDA instrument; (2) Determination of initial enrichment (IE) (σ DDA response increases (die-away time is longer) with increasing fissile content; and (2) Spent fuel => DDA response decreases (die-away time is shorter) with higher burn-up (i.e. more neutron absorbers present).

  10. Gearbox Instrumentation for the Investigation of Bearing Axial Cracking

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lambert, Scott R [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-03-27

    Failures in gearbox bearings have been the primary source of reliability issues for wind turbine drivetrains, leading to costly downtime and unplanned maintenance. The most common failure mode is attributed to so-called axial cracks or white-etching cracks, which primarily affect the intermediate and high-speed-stage bearings. The high-speed-shaft and bearing loads and sliding will be measured with a specially instrumented gearbox installed in a 1.5-megawatt turbine at the National Wind Technology Center in an upcoming test campaign. Additional instrumentation will also measure the tribological environment of these bearings, including bearing temperatures, lubricant temperature and water content, air temperature and humidity, and stray electrical current across the bearings. This paper fully describes the instrumentation package and summarizes initial results.

  11. Use and maintenance of nuclear medicine instruments in Southeast Asia

    International Nuclear Information System (INIS)

    1983-02-01

    Nuclear medicine instruments are rather sophisticated. They are difficult to maintain in effective working condition, especially in developing countries. The present document describes a survey conducted in Bangladesh, India, Malaysia, Pakistan, Philippines, Singapore, Sri Lanka and Thailand from October 1977 to March 1978, on the use and maintenance of nuclear medicine equipment. The survey evaluated the existing problems of instrument maintenance in the 8 countries visited. The major instruments in use were (1) scintillation probe counters, (2) well scintillation counters and (3) rectilinear cameras. Gamma camera was not widely available in the region at the time of the survey. Most of the surveyed instruments were kept in a detrimental environment resulting in a high failure rate, that caused the relatively high instrument unavailability of 11%. Insufficient bureaucratic handling of repair cases, difficulties with the supply of spare- and replacement parts and lack of training proved to be the main reasons for long periods of instrument inoperation. Remedial actions, based on the survey data, have been initiated

  12. Instrumental Capital

    Directory of Open Access Journals (Sweden)

    Gabriel Valerio

    2007-07-01

    Full Text Available During the history of human kind, since our first ancestors, tools have represented a mean to reach objectives which might otherwise seemed impossibles. In the called New Economy, where tangibles assets appear to be losing the role as the core element to produce value versus knowledge, tools have kept aside man in his dairy work. In this article, the author's objective is to describe, in a simple manner, the importance of managing the organization's group of tools or instruments (Instrumental Capital. The characteristic conditions of this New Economy, the way Knowledge Management deals with these new conditions and the sub-processes that provide support to the management of Instrumental Capital are described.

  13. Using XML and Java Technologies for Astronomical Instrument Control

    Science.gov (United States)

    Ames, Troy; Case, Lynne; Powers, Edward I. (Technical Monitor)

    2001-01-01

    Traditionally, instrument command and control systems have been highly specialized, consisting mostly of custom code that is difficult to develop, maintain, and extend. Such solutions are initially very costly and are inflexible to subsequent engineering change requests, increasing software maintenance costs. Instrument description is too tightly coupled with details of implementation. NASA Goddard Space Flight Center, under the Instrument Remote Control (IRC) project, is developing a general and highly extensible framework that applies to any kind of instrument that can be controlled by a computer. The software architecture combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML), a human readable and machine understandable way to describe structured data. A key aspect of the object-oriented architecture is that the software is driven by an instrument description, written using the Instrument Markup Language (IML), a dialect of XML. IML is used to describe the command sets and command formats of the instrument, communication mechanisms, format of the data coming from the instrument, and characteristics of the graphical user interface to control and monitor the instrument. The IRC framework allows the users to define a data analysis pipeline which converts data coming out of the instrument. The data can be used in visualizations in order for the user to assess the data in real-time, if necessary. The data analysis pipeline algorithms can be supplied by the user in a variety of forms or programming languages. Although the current integration effort is targeted for the High-resolution Airborne Wideband Camera (HAWC) and the Submillimeter and Far Infrared Experiment (SAFIRE), first-light instruments of the Stratospheric Observatory for Infrared Astronomy (SOFIA), the framework is designed to be generic and extensible so that it can be applied to any instrument. Plans are underway to test the framework

  14. Development of multifunctional radiation monitoring instrument based on PLC technology

    International Nuclear Information System (INIS)

    Li Ziqiang; Zhu Yuye; Zhuang Min

    2007-01-01

    This eight-channel multifunctional Radiation Monitoring Instrument is developed by making use of the built-in high-speed counters and the powerful instruction system of the SIEMES SIMATICS S7 series Programmable Logic Controllers (PLC) to record and process the pulse signal output by the detectors. The instrument with functions, such as analog and digital display, digital storage of digital data, pulse signal generator, network communication, can connect various types of pulse detectors. The initial process can be translated between Graduation Apparatus method and Formula method. the logicality of the high-dosage warning system is processed itself. The signal output will drive the alarm lights and bell directly. This paper mainly describes the configuration, programming and feature of the instrument. (authors)

  15. Use of microinterrupts to provide an instrument oriented input/output structure

    International Nuclear Information System (INIS)

    Zaky, S.G.

    1981-01-01

    This paper describes the design of a bit-slice based computer, which has been developed for use in data acquisition and control applications. The main design goals have been to provide fast response to external events, and sufficient processing capability to perform data reduction in real time. The initial application of this computer has been in airborne, geophysical surveying, where such instruments as Gamma-ray spectrometers, magnetometers and navigation equipment are involved. In order to meet the response requirement mentioned above, a microinterrupt facility has been incorporated. Microinterrupts are serviced in microcodes routines which can be initiated within a maximum of two microinstruction cycle times from an external event. This facility makes it possible to implement powerful input/output control functions without the need for complex and specialized hardware interfaces for each instrument. (orig.)

  16. The instruments in the first psychological laboratory in Mexico: antecedents, influence, and methods.

    Science.gov (United States)

    Escobar, Rogelio

    2014-11-01

    Enrique O. Aragón established the first psychological laboratory in Mexico in 1916. This laboratory was inspired by Wundt's laboratory and by those created afterward in Germany and the United States. It was equipped with state-of-the art instruments imported from Germany in 1902 from Ernst Zimmermann who supplied instruments for Wundt's laboratory. Although previous authors have described the social events leading to the creation of the laboratory, there are limited descriptions of the instruments, their use, and their influence. With the aid of archival resources, the initial location of the laboratory was determined. The analysis of instruments revealed a previously overlooked relation with a previous laboratory of experimental physiology. The influence of the laboratory was traced by describing the careers of 4 students, 3 of them women, who worked with the instruments during the first 2 decades of the 20th century, each becoming accomplished scholars. In addition, this article, by identifying and analyzing the instruments shown in photographs of the psychological laboratory and in 1 motion film, provides information of the class demonstrations and the experiments conducted in this laboratory.

  17. Long range radio tracking of sea turtles and polar bear: Instrumentation and preliminary results

    Science.gov (United States)

    Baldwin, H. A.

    1972-01-01

    Instrumentation developed for studies of path behavior of the green sea turtle and migration movement of polar bear is described. Preliminary results bearing on navigation ability in these species are presented. Both species operate in difficult environments, and the problems faced in the design of electronic instrumentation for these studies are not completely specified at this time. However, the critical factors yet to be understood are primarily related to the behavior of instrumented animals. The data obtained with these experimental techniques are included, first to illustrate the technique and, second to provide initial preliminary results bearing on animal navigation.

  18. Ontology Based Vocabulary Matching for Oceanographic Instruments

    Science.gov (United States)

    Chen, Yu; Shepherd, Adam; Chandler, Cyndy; Arko, Robert; Leadbetter, Adam

    2014-05-01

    Data integration act as the preliminary entry point as we enter the era of big data in many scientific domains. However the reusefulness of various dataset has met the hurdle due to different initial of interests of different parties, therefore different vocabularies in describing similar or semantically related concepts. In this scenario it is vital to devise an automatic or semi-supervised algorithm to facilitate the convergence of different vocabularies. The Ocean Data Interoperability Platform (ODIP) seeks to increase data sharing across scientific domains and international boundaries by providing a forum to harmonize diverse regional data systems. ODIP participants from the US include the Rolling Deck to Repository (R2R) program, whose mission is to capture, catalog, and describe the underway/environmental sensor data from US oceanographic research vessels and submit the data to public long-term archives. In an attempt to harmonize these regional data systems, especially vocabularies, R2R recognizes the value of the SeaDataNet vocabularies served by the NERC Vocabulary Server (NVS) hosted at the British Oceanographic Data Centre as a trusted, authoritative source for describing many oceanographic research concepts such as instrumentation. In this work, we make use of the semantic relations in the vocabularies served by NVS to build a Bayesian network and take advantage of the idea of entropy in evaluating the correlation between different concepts and keywords. The performance of the model is evaluated against matching instruments from R2R against the SeaDataNet instrument vocabularies based on calculated confidence scores in the instrument pairings. These pairings with their scores can then be analyzed for assertion growing the interoperability of the R2R vocabulary through its links to the SeaDataNet entities.

  19. Nuclear reactor instrumentation

    International Nuclear Information System (INIS)

    Duncombe, E.; McGonigal, G.

    1975-01-01

    A liquid metal cooled nuclear reactor is described which has an equal number of fuel sub-assemblies and sensing instruments. Each instrument senses temperature and rate of coolant flow of a coolant derived from a group of three sub-assemblies so that an abnormal value for one sub-assembly will be indicated on three instruments thereby providing for redundancy of up to two of the three instruments. The abnormal value may be a precurser to unstable boiling of coolant

  20. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  1. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  2. Effect of the size of the apical enlargement with rotary instruments, single-cone filling, post space preparation with drills, fiber post removal, and root canal filling removal on apical crack initiation and propagation.

    Science.gov (United States)

    Çapar, İsmail Davut; Uysal, Banu; Ok, Evren; Arslan, Hakan

    2015-02-01

    The purpose of this study was to investigate the incidence of apical crack initiation and propagation in root dentin after several endodontic procedures. Sixty intact mandibular premolars were sectioned perpendicular to the long axis at 1 mm from the apex, and the apical surface was polished. Thirty teeth were left unprepared and served as a control, and the remaining 30 teeth were instrumented with ProTaper Universal instruments (Dentsply Maillefer, Ballaigues, Switzerland) up to size F5. The root canals were filled with the single-cone technique. Gutta-percha was removed with drills of the Rebilda post system (VOCO, Cuxhaven, Germany). Glass fiber-reinforced composite fiber posts were cemented using a dual-cure resin cement. The fiber posts were removed with a drill of the post system. Retreatment was completed after the removal of the gutta-percha. Crack initiation and propagation in the apical surfaces of the samples were examined with a stereomicroscope after each procedure. The absence/presence of cracks was recorded. Logistic regression was performed to analyze statistically the incidence of crack initiation and propagation with each procedure. The initiation of the first crack and crack propagation was associated with F2 and F4 instruments, respectively. The logistic regression analysis revealed that instrumentation and F2 instrument significantly affected apical crack initiation (P .05). Rotary nickel-titanium instrumentation had a significant effect on apical crack initiation, and post space preparation with drills had a significant impact on crack propagation. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Instrumentation for the study of low emittance tuning and beam dynamics at CESR

    Science.gov (United States)

    Billing, M. G.; Dobbins, J. A.; Forster, M. J.; Kreinick, D. L.; Meller, R. E.; Peterson, D. P.; Ramirez, G. A.; Rendina, M. C.; Rider, N. T.; Sagan, D. C.; Shanks, J.; Sikora, J. P.; Stedinger, M. G.; Strohman, C. R.; Williams, H. A.; Palmer, M. A.; Holtzapple, R. L.; Flanagan, J.

    2017-11-01

    The Cornell Electron-positron Storage Ring (CESR) has been converted from a High Energy Physics electron-positron collider to operate as a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS) and to conduct accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Some of the specific topics that were targeted for the initial phase of operation of the storage ring in this mode for CESR as a Test Accelerator (CesrTA) included 1) tuning techniques to produce low emittance beams, 2) the study of electron cloud development in a storage ring and 3) intra-beam scattering effects. The complete conversion of CESR to CesrTA occurred over a several year period, described elsewhere [1-3]. In addition to instrumentation for the storage ring, which was created for CesrTA, existing instrumentation was modified to facilitate the entire range of investigations to support these studies. Procedures were developed, often requiring coordinated measurements among different instruments [4]. This paper describes the instruments utilized for the study of beam dynamics during the operation of CesrTA. The treatment of these instruments will remain fairly general in this paper as it focusses on an overview of the instruments themselves. Their interaction and inter-relationships during sequences of observations is found in a companion paper describing the associated measurement techniques. More detailed descriptions and detailed operational performance for some of the instrumentation may be found elsewhere and these will be referenced in the related sections of this paper.

  4. Een helpende hand bij snelhedenbeleid gericht op veiligheid en geloofwaardigheid : eerste aanzet voor een beslissingsondersteunend instrument voor veilige snelheden en geloofwaardige snelheidslimieten.

    NARCIS (Netherlands)

    Aarts, L.T. & Nes, C.N. van

    2008-01-01

    One of the Dutch regions asked SWOV to help with the development of a decision-support instrument for safe speeds and credible speed limits, hence abbreviated to SSCS. This report describes an initial impetus to the functioning of this instrument which is yet to be developed: the SSCS model. The

  5. The High Visible Resolution (HVR) instrument of the spot ground observation satellite

    Science.gov (United States)

    Otrio, G.

    1980-01-01

    Two identical high resolution cameras, capable of attaining a track width of 116 km in an almost vertical line of sight from the two 60 km images of each instrument, will be carried on the initial mission of the space observation of Earth satellite (SPOT). Specifications for the instrument, including the telescope and CCD devices are summarized. The present status of development is described including the optical characteristics, structure and thermal control, detector assembly, electronic equipment, and calibration. SPOT mission objectives include the developments relating to soil use, the exploration of EART Earth resources, the discrimination of plant species, and cartography.

  6. The Sensors and Instrumentation Knowledge Transfer Network

    International Nuclear Information System (INIS)

    Cooper, P

    2009-01-01

    The Sensors and Instrumentation KTN has established itself as the UK's national network in sensors and instrumentation, developing a community of over 2,250 member organisations. This paper describes the background to Knowledge Transfer Networks (KTNs) and the changes that are happening to KTNs at a national level, before describing the market size, activities and successes of the Sensors and Instrumentation KTN. The paper concludes by describing the merger between the Sensors and Instrumentation KTN and four other KTNs to create a new KTN, with a working title of the Electronics, Sensors and Photonics KTN.

  7. Patient-Reported Outcome and Quality of Life Instruments Database (PROQOLID: Frequently asked questions

    Directory of Open Access Journals (Sweden)

    Perrier Laure-Lou

    2005-03-01

    Full Text Available Abstract The exponential development of Patient-Reported Outcomes (PRO measures in clinical research has led to the creation of the Patient-Reported Outcome and Quality of Life Instruments Database (PROQOLID to facilitate the selection process of PRO measures in clinical research. The project was initiated by Mapi Research Trust in Lyon, France. Initially called QOLID (Quality of Life Instruments Database, the project's purpose was to provide all those involved in health care evaluation with a comprehensive and unique source of information on PRO and HRQOL measures available through the Internet. PROQOLID currently describes more than 470 PRO instruments in a structured format. It is available in two levels, non-subscribers and subscribers, at http://www.proqolid.org. The first level is free of charge and contains 14 categories of basic useful information on the instruments (e.g. author, objective, original language, list of existing translations, etc.. The second level provides significantly more information about the instruments. It includes review copies of over 350 original instruments, 120 user manuals and 350 translations. Most are available in PDF format. This level is only accessible to annual subscribers. PROQOLID is updated in close collaboration with the instruments' authors on a regular basis. Fifty or more new instruments are added to the database annually. Today, all of the major pharmaceutical companies, prestigious institutions (such as the FDA, the NIH's National Cancer Institute, the U.S. Veterans Administration, dozens of universities, public institutions and researchers subscribe to PROQOLID on a yearly basis. More than 800 users per day routinely visit the database.

  8. Astronomical Instruments in India

    Science.gov (United States)

    Sarma, Sreeramula Rajeswara

    The earliest astronomical instruments used in India were the gnomon and the water clock. In the early seventh century, Brahmagupta described ten types of instruments, which were adopted by all subsequent writers with minor modifications. Contact with Islamic astronomy in the second millennium AD led to a radical change. Sanskrit texts began to lay emphasis on the importance of observational instruments. Exclusive texts on instruments were composed. Islamic instruments like the astrolabe were adopted and some new types of instruments were developed. Production and use of these traditional instruments continued, along with the cultivation of traditional astronomy, up to the end of the nineteenth century.

  9. Describing Instrumental Music Teachers' Thinking: Implications for Understanding Pedagogical Content Knowledge

    Science.gov (United States)

    Millican, J. Si

    2013-01-01

    Pedagogical content knowledge, the particular ways that teachers understand their subjects in order to instruct others, has been described and explored in the math and science education fields in some depth, yet little research exists illustrating this concept in music instruction. I used a descriptive approach to explore expert beginning band…

  10. Teen drivers' awareness of vehicle instrumentation in naturalistic research.

    Science.gov (United States)

    Ehsani, J P; Haynie, D; Ouimet, M C; Zhu, C; Guillaume, C; Klauer, S G; Dingus, T; Simons-Morton, B G

    2017-12-01

    Naturalistic driving methods require the installation of instruments and cameras in vehicles to record driving behavior. A critical, yet unexamined issue in naturalistic driving research is the extent to which the vehicle instruments and cameras used for naturalistic methods change human behavior. We sought to describe the degree to which teenage participants' self-reported awareness of vehicle instrumentation changes over time, and whether that awareness was associated with driving behaviors. Forty-two newly-licensed teenage drivers participated in an 18-month naturalistic driving study. Data on driving behaviors including crash/near-crashes and elevated gravitational force (g-force) events rates were collected over the study period. At the end of the study, participants were asked to rate the extent to which they were aware of instruments in the vehicle at four time points. They were also asked to describe their own and their passengers' perceptions of the instrumentation in the vehicle during an in-depth interview. The number of critical event button presses was used as a secondary measure of camera awareness. The association between self-reported awareness of the instrumentation and objectively measured driving behaviors was tested using correlations and linear mixed models. Most participants' reported that their awareness of vehicle instrumentation declined across the duration of the 18-month study. Their awareness increased in response to their passengers' concerns about the cameras or if they were involved in a crash. The number of the critical event button presses was initially high and declined rapidly. There was no correlation between driver's awareness of instrumentation and their crash and near-crash rate or elevated g-force events rate. Awareness was not associated with crash and near-crash rates or elevated g-force event rates, consistent with having no effect on this measure of driving performance. Naturalistic driving studies are likely to yield

  11. Use of Adult Patient Focus Groups to Develop the Initial Item Bank for a Cochlear Implant Quality-of-Life Instrument.

    Science.gov (United States)

    McRackan, Theodore R; Velozo, Craig A; Holcomb, Meredith A; Camposeo, Elizabeth L; Hatch, Jonathan L; Meyer, Ted A; Lambert, Paul R; Melvin, Cathy L; Dubno, Judy R

    2017-10-01

    No instrument exists to assess quality of life (QOL) in adult cochlear implant (CI) users that has been developed and validated using accepted scientific standards. To develop a CI-specific QOL instrument for adults in accordance with the Patient Reported Outcomes Measurement Information System (PROMIS) guidelines. As required in the PROMIS guidelines, patient focus groups participated in creation of the initial item bank. Twenty-three adult CI users were divided into 1 of 3 focus groups stratified by word recognition ability. Three moderator-led focus groups were conducted based on grounded theory on December 3, 2016. Two reviewers independently analyzed focus group recordings and transcripts, with a third reviewer available to resolve discrepancies. All data were reviewed and reported according to the Consolidated Criteria for Reporting Qualitative Research. The setting was a tertiary referral center. Coded focus group data. The 23 focus group participants (10 [43%] female; mean [range] age, 68.1 [46.2-84.2] years) represented a wide range of income levels, education levels, listening modalities, CI device manufacturers, duration of CI use, and age at implantation. Data saturation was determined to be reached before the conclusion of each of the focus groups. After analysis of the transcripts, the central themes identified were communication, emotion, environmental sounds, independence and work function, listening effort, social isolation and ability to socialize, and sound clarity. Cognitive interviews were carried out on 20 adult CI patients who did not participate in the focus groups to ensure item clarity. Based on these results, the initial QOL item bank and prototype were developed. Patient focus groups drawn from the target population are the preferred method of identifying content areas and domains for developing the item bank for a CI-specific QOL instrument. Compared with previously used methods, the use of patient-centered item development for a CI

  12. Project W-314 DST and DCRT instrument and control systems, initial assessment

    International Nuclear Information System (INIS)

    Acree, C.D.

    1996-01-01

    This report contains an assessment of the instrument and control systems in the Double Shell Tank Farms and the 244-A DCRT. The assessment report contains data from physical inspection activities and an overall engineering assessment of the instruments and control systems in use in the Double Shell Tanks

  13. Status of safeguards instrumentation

    International Nuclear Information System (INIS)

    Higinbotham, W.A.

    The International Atomic Energy Agency is performing safeguards at some nuclear power reactors, 50 bulk processing facilities, and 170 research facilities. Its verification activities require the use of instruments to measure nuclear materials and of surveillance instruments to maintain continuity of knowledge of the locations of nuclear materials. Instruments that are in use and under development to measure weight, volume, concentration, and isotopic composition of nuclear materials, and the major surveillance instruments, are described in connection with their uses at representative nuclear facilities. The current status of safeguards instrumentation and the needs for future development are discussed

  14. VIRUS instrument enclosures

    Science.gov (United States)

    Prochaska, T.; Allen, R.; Mondrik, N.; Rheault, J. P.; Sauseda, M.; Boster, E.; James, M.; Rodriguez-Patino, M.; Torres, G.; Ham, J.; Cook, E.; Baker, D.; DePoy, Darren L.; Marshall, Jennifer L.; Hill, G. J.; Perry, D.; Savage, R. D.; Good, J. M.; Vattiat, Brian L.

    2014-08-01

    The Visible Integral-Field Replicable Unit Spectrograph (VIRUS) instrument will be installed at the Hobby-Eberly Telescope† in the near future. The instrument will be housed in two enclosures that are mounted adjacent to the telescope, via the VIRUS Support Structure (VSS). We have designed the enclosures to support and protect the instrument, to enable servicing of the instrument, and to cool the instrument appropriately while not adversely affecting the dome environment. The system uses simple HVAC air handling techniques in conjunction with thermoelectric and standard glycol heat exchangers to provide efficient heat removal. The enclosures also provide power and data transfer to and from each VIRUS unit, liquid nitrogen cooling to the detectors, and environmental monitoring of the instrument and dome environments. In this paper, we describe the design and fabrication of the VIRUS enclosures and their subsystems.

  15. Instrument for detecting gas bubbles in sodium filled pipework

    Energy Technology Data Exchange (ETDEWEB)

    Stapleton, D

    1973-08-01

    An instrument employing an electromagnetic sensor is described. Gas bubbles down to 0.5 mm diameter can be detected in sodium filled pipework of 1 in. nominal bore at temperatures up to 400 deg C. Installation of the sensing head involves no break in the integrity of the pipework. Facilities to enable bubble size discrimination, bubble counting and timing pulse generation are provided in the signal processing unit. Initial operating experience has been gained on a sodium loop used for gas entrainment studies. (auth)

  16. Seismic instrumentation for nuclear power plants

    International Nuclear Information System (INIS)

    Senne Junior, M.

    1983-01-01

    A seismic instrumentation system used in Nuclear Power Plants to monitor the design parameters of systems, structures and components, needed to provide safety to those Plants, against the action of earthquakes is described. The instrumentation described is based on the nuclear standards in force. The minimum amount of sensors and other components used, as well as their general localization, is indicated. The operation of the instrumentation system as a whole and the handling of the recovered data are dealt with accordingly. The various devices used are not covered in detail, except for the accelerometer, which is the seismic instrumentation basic component. (Author) [pt

  17. Modularized Parallel Neutron Instrument Simulation on the TeraGrid

    International Nuclear Information System (INIS)

    Chen, Meili; Cobb, John W.; Hagen, Mark E.; Miller, Stephen D.; Lynch, Vickie E.

    2007-01-01

    In order to build a bridge between the TeraGrid (TG), a national scale cyberinfrastructure resource, and neutron science, the Neutron Science TeraGrid Gateway (NSTG) is focused on introducing productive HPC usage to the neutron science community, primarily the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). Monte Carlo simulations are used as a powerful tool for instrument design and optimization at SNS. One of the successful efforts of a collaboration team composed of NSTG HPC experts and SNS instrument scientists is the development of a software facility named PSoNI, Parallelizing Simulations of Neutron Instruments. Parallelizing the traditional serial instrument simulation on TeraGrid resources, PSoNI quickly computes full instrument simulation at sufficient statistical levels in instrument de-sign. Upon SNS successful commissioning, to the end of 2007, three out of five commissioned instruments in SNS target station will be available for initial users. Advanced instrument study, proposal feasibility evaluation, and experiment planning are on the immediate schedule of SNS, which pose further requirements such as flexibility and high runtime efficiency on fast instrument simulation. PSoNI has been redesigned to meet the new challenges and a preliminary version is developed on TeraGrid. This paper explores the motivation and goals of the new design, and the improved software structure. Further, it describes the realized new features seen from MPI parallelized McStas running high resolution design simulations of the SEQUOIA and BSS instruments at SNS. A discussion regarding future work, which is targeted to do fast simulation for automated experiment adjustment and comparing models to data in analysis, is also presented

  18. Design of a Channel Error Simulator using Virtual Instrument Techniques for the Initial Testing of TCP/IP and SCPS Protocols

    Science.gov (United States)

    Horan, Stephen; Wang, Ru-Hai

    1999-01-01

    There exists a need for designers and developers to have a method to conveniently test a variety of communications parameters for an overall system design. This is no different when testing network protocols as when testing modulation formats. In this report, we discuss a means of providing a networking test device specifically designed to be used for space communications. This test device is a PC-based Virtual Instrument (VI) programmed using the LabVIEW(TM) version 5 software suite developed by National Instruments(TM)TM. This instrument was designed to be portable and usable by others without special, additional equipment. The programming was designed to replicate a VME-based hardware module developed earlier at New Mexico State University (NMSU) and to provide expanded capabilities exceeding the baseline configuration existing in that module. This report describes the design goals for the VI module in the next section and follows that with a description of the design of the VI instrument. This is followed with a description of the validation tests run on the VI. An application of the error-generating VI to networking protocols is then given.

  19. Energetic neutral atom imaging with the Polar CEPPAD/IPS instrument: Initial forward modeling results

    International Nuclear Information System (INIS)

    Henderson, M.G.; Reeves, G.D.; Moore, K.R.; Spence, H.E.; Jorgensen, A.M.; Roelof, E.C.

    1997-01-01

    Although the primary function of the CEP-PAD/IPS instrument on Polar is the measurement of energetic ions in-situ, it has also proven to be a very capable Energetic neutral Atom (ENA) imager. Raw ENA images are currently being constructed on a routine basis with a temporal resolution of minutes during both active and quiet times. However, while analyses of these images by themselves provide much information on the spatial distribution and dynamics of the energetic ion population in the ring current, detailed modeling is required to extract the actual ion distributions. In this paper, the authors present the initial results of forward modeling an IPS ENA image obtained during a small geo-magnetic storm on June 9, 1997. The equatorial ion distribution inferred with this technique reproduces the expected large noon/midnight and dawn/dusk asymmetries. The limitations of the model are discussed and a number of modifications to the basic forward modeling technique are proposed which should significantly improve its performance in future studies

  20. Seismic instrumentation for nuclear power plants

    International Nuclear Information System (INIS)

    Senne Junior, M.

    1983-07-01

    A seismic instrumentation system used in Nuclear Power Plants to monitor the design parameters of systems, structures and components, needed to provide safety to those plants, against the action of earth quarks is described. The instrumentation is based on the nuclear standards and other components used, as well as their general localization is indicated. The operation of the instrumentation system as a whole and the handling of the recovered data are dealt with accordingly. The accelerometer is described in detail. (Author) [pt

  1. Instrumentation for three-dimensional tomography

    International Nuclear Information System (INIS)

    Derenzo, S.E.

    1981-01-01

    The Donner 280-crystal positron tomograph is described and its operation is explained. The instrument was put into operation in 1978. Possible uses of this instrument in human and animal studies are given

  2. Californium interrogation prompt neutron (CIPN) instrument for non-destructive assay of spent nuclear fuel—Design concept and experimental demonstration

    International Nuclear Information System (INIS)

    Henzlova, D.; Menlove, H.O.; Rael, C.D.; Trellue, H.R.; Tobin, S.J.; Park, Se-Hwan; Oh, Jong-Myeong; Lee, Seung-Kyu; Ahn, Seong-Kyu; Kwon, In-Chan; Kim, Ho-Dong

    2016-01-01

    This paper presents results of the first experimental demonstration of the Californium Interrogation Prompt Neutron (CIPN) instrument developed within a multi-year effort launched by the Next Generation Safeguards Initiative Spent Fuel Project of the United States Department of Energy. The goals of this project focused on developing viable non-destructive assay techniques with capabilities to improve an independent verification of spent fuel assembly characteristics. For this purpose, the CIPN instrument combines active and passive neutron interrogation, along with passive gamma-ray measurements, to provide three independent observables. This paper describes the initial feasibility demonstration of the CIPN instrument, which involved measurements of four pressurized-water-reactor spent fuel assemblies with different levels of burnup and two initial enrichments. The measurements were performed at the Post-Irradiation Examination Facility at the Korea Atomic Energy Institute in the Republic of Korea. The key aim of the demonstration was to evaluate CIPN instrument performance under realistic deployment conditions, with the focus on a detailed assessment of systematic uncertainties that are best evaluated experimentally. The measurements revealed good positioning reproducibility, as well as a high degree of insensitivity of the CIPN instrument's response to irregularities in a radial burnup profile. Systematic uncertainty of individual CIPN instrument signals due to assembly rotation was found to be <4.5%, even for assemblies with fairly extreme gradients in the radial burnup profile. These features suggest that the CIPN instrument is capable of providing a good representation of assembly average characteristics, independent of assembly orientation in the instrument.

  3. Californium interrogation prompt neutron (CIPN) instrument for non-destructive assay of spent nuclear fuel—Design concept and experimental demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Henzlova, D., E-mail: henzlova@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Menlove, H.O.; Rael, C.D.; Trellue, H.R.; Tobin, S.J. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Park, Se-Hwan; Oh, Jong-Myeong; Lee, Seung-Kyu; Ahn, Seong-Kyu; Kwon, In-Chan; Kim, Ho-Dong [Korea Atomic Energy Research Institute, Daejeong (Korea, Republic of)

    2016-01-11

    This paper presents results of the first experimental demonstration of the Californium Interrogation Prompt Neutron (CIPN) instrument developed within a multi-year effort launched by the Next Generation Safeguards Initiative Spent Fuel Project of the United States Department of Energy. The goals of this project focused on developing viable non-destructive assay techniques with capabilities to improve an independent verification of spent fuel assembly characteristics. For this purpose, the CIPN instrument combines active and passive neutron interrogation, along with passive gamma-ray measurements, to provide three independent observables. This paper describes the initial feasibility demonstration of the CIPN instrument, which involved measurements of four pressurized-water-reactor spent fuel assemblies with different levels of burnup and two initial enrichments. The measurements were performed at the Post-Irradiation Examination Facility at the Korea Atomic Energy Institute in the Republic of Korea. The key aim of the demonstration was to evaluate CIPN instrument performance under realistic deployment conditions, with the focus on a detailed assessment of systematic uncertainties that are best evaluated experimentally. The measurements revealed good positioning reproducibility, as well as a high degree of insensitivity of the CIPN instrument's response to irregularities in a radial burnup profile. Systematic uncertainty of individual CIPN instrument signals due to assembly rotation was found to be <4.5%, even for assemblies with fairly extreme gradients in the radial burnup profile. These features suggest that the CIPN instrument is capable of providing a good representation of assembly average characteristics, independent of assembly orientation in the instrument.

  4. Nuclear instrumentation for research reactors

    International Nuclear Information System (INIS)

    Hofer, Carlos G.; Pita, Antonio; Verrastro, Claudio A.; Maino, Eduardo J.

    1997-01-01

    The nuclear instrumentation for research reactors in Argentina was developed in 70'. A gradual modernization of all the nuclear instrumentation is planned. It includes start-up and power range instrumentation, as well as field monitors, clamp, scram and rod movement control logic. The new instrumentation is linked to a computer network, based on real time operating system for data acquisition, display and logging. This paper describes the modules and whole system aspects. (author). 2 refs

  5. An Evaluation Instrument for Object-Oriented Example Programs for Novices

    DEFF Research Database (Denmark)

    Christensen, Henrik Bærbak; Börstler, Jürgen; Nordström,, Marie

    objectively and consistently requires some kind of measurement instrument. In this paper, we describe the development and initial validation of an evaluation instrument for example programs, based on three aspects of quality; technical quality, object-oriented quality, and didactical quality. Validation......Examples are important tools for programming education. In this paper, we investigate desirable properties of programming examples from a cognitive and a measurement point of view. We argue that some cognitive aspects of example programs are "caught" by common software measures......, but they are not sufficient to capture all important aspects of understandability. We propose a framework for measuring the understandability of example programs that also considers factors related to the usage context of examples. Research shows that examples play an important role for cognitive skill acquisition. Students...

  6. Making the Grade: Describing Inherent Requirements for the Initial Teacher Education Practicum

    Science.gov (United States)

    Sharplin, Elaine; Peden, Sanna; Marais, Ida

    2016-01-01

    This study explores the development, description, and illustration of inherent requirement (IR) statements to make explicit the requirements for performance on an initial teacher education (ITE) practicum. Through consultative group processes with stakeholders involved in ITE, seven IR domains were identified. From interviews with academics,…

  7. Advanced In-Pile Instrumentation for Materials Testing Reactors

    Science.gov (United States)

    Rempe, J. L.; Knudson, D. L.; Daw, J. E.; Unruh, T. C.; Chase, B. M.; Davis, K. L.; Palmer, A. J.; Schley, R. S.

    2014-08-01

    The U.S. Department of Energy sponsors the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) program to promote U.S. research in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR NSUF facilitates basic and applied nuclear research and development, advancing U.S. energy security needs. A key component of the ATR NSUF effort is to design, develop, and deploy new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. This paper describes the strategy developed by the Idaho National Laboratory (INL) for identifying instrumentation needed for ATR irradiation tests and the program initiated to obtain these sensors. New sensors developed from this effort are identified, and the progress of other development efforts is summarized. As reported in this paper, INL researchers are currently involved in several tasks to deploy real-time length and flux detection sensors, and efforts have been initiated to develop a crack growth test rig. Tasks evaluating `advanced' technologies, such as fiber-optics based length detection and ultrasonic thermometers, are also underway. In addition, specialized sensors for real-time detection of temperature and thermal conductivity are not only being provided to NSUF reactors, but are also being provided to several international test reactors.

  8. HTGR Measurements and Instrumentation Systems

    International Nuclear Information System (INIS)

    Ball, Sydney J.; Holcomb, David Eugene; Cetiner, Mustafa Sacit

    2012-01-01

    This report provides an integrated overview of measurements and instrumentation for near-term future high-temperature gas-cooled reactors (HTGRs). Instrumentation technology has undergone revolutionary improvements since the last HTGR was constructed in the United States. This report briefly describes the measurement and communications needs of HTGRs for normal operations, maintenance and inspection, fuel fabrication, and accident response. The report includes a description of modern communications technologies and also provides a potential instrumentation communications architecture designed for deployment at an HTGR. A principal focus for the report is describing new and emerging measurement technologies with high potential to improve operations, maintenance, and accident response for the next generation of HTGRs, known as modular HTGRs, which are designed with passive safety features. Special focus is devoted toward describing the failure modes of the measurement technologies and assessing the technology maturity.

  9. Report of the Instrumentation Service - Annex C

    International Nuclear Information System (INIS)

    Mikic, N.; Majstorovic, D.

    1993-01-01

    This report describes the tasks and organizational structure of the Instrumentation service. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment, inspection of the reactor vessel and spent fuel storage pool and describes activities related to renewal of the equipment [sr

  10. Report of the Instrumentation Service - Annex C

    International Nuclear Information System (INIS)

    Mikic, N.

    1999-01-01

    This report describes the tasks and organizational structure of the Instrumentation service. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment, inspection of the reactor vessel and spent fuel storage pool and describes activities related control and maintenace of the experimental devices [sr

  11. Report of the Instrumentation Service - Annex C

    International Nuclear Information System (INIS)

    Mikic, N.

    2000-01-01

    This report describes the tasks and organizational structure of the Instrumentation service. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment, inspection of the reactor vessel and spent fuel storage pool and describes activities related control and maintenace of the experimental devices [sr

  12. Report of the Instrumentation Service - Annex C

    International Nuclear Information System (INIS)

    Majstorovic, D.

    1986-01-01

    This report describes the tasks and organizational structure of the Instrumentation service. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment, inspection of the reactor vessel and spent fuel storage pool and describes activities related to renewal of the equipment [sr

  13. Report of the Instrumentation Service - Annex C

    International Nuclear Information System (INIS)

    Majstorovic, D.

    1988-01-01

    This report describes the tasks and organizational structure of the Instrumentation service. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment, inspection of the reactor vessel and spent fuel storage pool and describes activities related to renewal of the equipment [sr

  14. Development and initial validation of an instrument to assess stressors among South African sports coaches.

    Science.gov (United States)

    Kubayi, Alliance; Toriola, Abel; Didymus, Faye

    2018-06-01

    The aim of this series of studies was to develop and initially validate an instrument to assess stressors among South African sports coaches. In study one, a preliminary pool of 45 items was developed based on existing literature and an expert panel was employed to assess the content validity and applicability of these items. In study two, the 32 items that were retained after study one were analysed using principal component analysis (PCA). The resultant factorial structure comprised four components: environmental stressors, performance stressors, task-related stressors, and athlete stressors. These four components were made up of 26 items and, together, the components and items comprised the provisional Stressors in Sports Coaching Questionnaire (SSCQ). The results show that the SSCQ demonstrates acceptable internal consistency (.73-.89). The findings provide preliminary evidence that SSCQ is a valid tool to assess stressors among South African sports coaches.

  15. Development of the Electron Drift Instrument (EDI) for Cluster

    Science.gov (United States)

    Quinn, Jack; Christensen, John L. (Technical Monitor)

    2001-01-01

    The Electron Drift Instrument (EDI) is a new technique for measuring electric fields in space by detecting the effect on weak beams of test electrons. This U.S. portions of the technique, flight hardware, and flight software were developed for the Cluster mission under this contract. Dr. Goetz Paschmann of the Max Planck Institute in Garching, Germany, was the Principle Investigator for Cluster EDI. Hardware for Cluster was developed in the U.S. at the University of New Hampshire, Lockheed Palo Alto Research Laboratory, and University of California, San Diego. The Cluster satellites carrying the original EDI instruments were lost in the catastrophic launch failure of first flight of the Arianne-V rocket in 1996. Following that loss, NASA and ESA approved a rebuild of the Cluster mission, for which all four satellites were successfully launched in the Summer of 2000. Limited operations of EDI were also obtained on the Equator-S satellite, which was launched in December, 1997. A satellite failure caused a loss of the Equator-S mission after only 5 months, but these operations were extremely valuable in learning about the characteristics and operations of the complex EDI instrument. The Cluster mission, satellites, and instruments underwent an extensive on-orbit commissioning phase in the Fall of 2000, carrying over through January 2001. During this period all elements of the instruments were checked and careful measurements of inter-experiments interferences were made. EDI is currently working exceptionally well in orbit. Initial results verify that all aspects of the instrument are working as planned, and returning highly valuable scientific information. The first two papers describing EDI on-orbit results have been submitted for publication in April, 2001. The principles of the EDI technique, and its implementation on Cluster are described in two papers by Paschmann et al., attached as Appendices A and B. The EDI presentation at the formal Cluster Commissioning

  16. Development of CAMAC and Fastbus instrumentation

    International Nuclear Information System (INIS)

    Venkateswaran, Aruna; Behere, Anita; Ghodgaonkar, M.D.; Bairi, B.R.

    1987-01-01

    This report describes the work being done towards the development of CAMAC and Fast Bus Instrumentation under the VII Five Year Plan Project 'Modernisation of Reactor Control Instrumentation and Development of CAMAC and FAST BUS Instrumentation'. The report summarises the goals, objectives, principles and concepts of CAMAC and Fast Bus Instrumentation. While emphasizing the motivation behind the development of CAMAC and Fast Bus Instrumentation, the report brings out the current status and future plans of this development program. (author)

  17. MEASURING COERCION TO PARTICIPATE IN RESEARCH WITHIN A DOUBLY VULNERABLE POPULATION: INITIAL DEVELOPMENT OF THE COERCION ASSESSMENT SCALE

    Science.gov (United States)

    Dugosh, Karen Leggett; Festinger, David S.; Croft, Jason R.; Marlowe, Douglas B.

    2011-01-01

    Despite many efforts aimed to ensure that research participation is autonomous and not coerced, there exists no reliable and valid measure of perceived coercion for the doubly vulnerable population of substance-abusing offenders. The current study describes the development and initial validation of an instrument measuring perceived coercion to participate in research among substance-abusing offenders. The results indicated that a substantial number of individuals report feeling coerced to participate in the study. In addition, the instrument has adequate levels of internal consistency, a one-dimensional factor structure, and evidence of discriminative validity. This study provides initial support for the instrument’s validity and clinical utility. PMID:20235867

  18. Soil monitoring instrumentation

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1980-01-01

    The Los Alamos Scientific Laboratory (LASL) has an extensive program for the development of nondestructive assay instrumentation for the quantitative analysis of transuranic (TRU) materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. Included are wastes generated in decontamination and decommissioning of outdated nuclear facilities as well as wastes from old waste burial ground exhumation programs. The assay instrumentation is designed to have detection limits below 10 nCi/g wherever practicable. Because of the topic of this workshop, only the assay instrumentation applied specifically to soil monitoring will be discussed here. Four types of soil monitors are described

  19. The Squiggle: A Digital Musical Instrument

    OpenAIRE

    Sheehan, Brian

    2004-01-01

    This paper discusses some of the issues pertaining to thedesign of digital musical instruments that are to effectively fillthe role of traditional instruments (i.e. those based on physicalsound production mechanisms). The design andimplementation of a musical instrument that addresses some ofthese issues, using scanned synthesis coupled to a "smart"physical system, is described.

  20. Advanced In-pile Instrumentation for Material and Test Reactors

    International Nuclear Information System (INIS)

    Rempe, J.L.; Knudson, D.L.; Daw, J.E.; Unruh, T.C.; Chase, B.M.; Davis, K.L.; Palmer, A.J.; Schley, R.S.

    2013-06-01

    The US Department of Energy sponsors the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) program to promote U.S. research in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR NSUF facilitates basic and applied nuclear research and development, advancing U.S. energy security needs. A key component of the ATR NSUF effort is to design, develop, and deploy new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. This paper describes the strategy developed by the Idaho National Laboratory (INL) for identifying instrumentation needed for ATR irradiation tests and the program initiated to obtain these sensors. New sensors developed from this effort are identified; and the progress of other development efforts is summarized. As reported in this paper, INL staff is currently involved in several tasks to deploy real-time length and flux detection sensors, and efforts have been initiated to develop a crack growth test rig. Tasks evaluating 'advanced' technologies, such as fiber-optics based length detection and ultrasonic thermometers are also underway. In addition, specialized sensors for real-time detection of temperature and thermal conductivity are not only being provided to NSUF reactors, but are also being provided to several international test reactors. (authors)

  1. Designing an Instrument to Measure the QoS of a Spanish Virtual Store

    Science.gov (United States)

    de Abajo, Beatriz Sainz; de La Torre Díez, Isabel; Salcines, Enrique García; Fernández, Javier Burón; Pernas, Francisco Díaz; Coronado, Miguel López; de Castro Lozano, Carlos

    This article describes the development of an instrument, in the form of a survey, which is distributed to users of a B2C website selling electronic books in order to ascertain their satisfaction. The opinions compiled from a pilot sample and the exploratory factor analysis carried out point to factors that best summarise the quality of the application analysed here. Analysis of the initial survey, with a total of 40 items, shaped the final instrument, encompassing 18 items divided into 6 dimensions, which measure the perceptions of users of the application in order to improve the contents of the website. Subsequently, a confirmatory factorial analysis is performed, ensuring the reliability of the study and which confirms that the structure of the instrument developed truly measures service quality in accordance with the requirements of the website in terms of offering a space that fulfils consumer expectations in the Information Society.

  2. Development and initial validation of the Pharmacist Frequency of Interprofessional Collaboration Instrument (FICI-P) in primary care.

    Science.gov (United States)

    Van, Connie; Costa, Daniel; Mitchell, Bernadette; Abbott, Penny; Krass, Ines

    2012-01-01

    Existing validated measures of pharmacist-physician collaboration focus on measuring attitudes toward collaboration and do not measure frequency of collaborative interactions. To develop and validate an instrument to measure the frequency of collaboration between pharmacists and general practitioners (GPs) from the pharmacist's perspective. An 11-item Pharmacist Frequency of Interprofessional Collaboration Instrument (FICI-P) was developed and administered to 586 pharmacists in 8 divisions of general practice in New South Wales, Australia. The initial items were informed by a review of the literature in addition to interviews of pharmacists and GPs. Items were subjected to principal component and Rasch analyses to determine each item's and the overall measure's psychometric properties and for any needed refinements. Two hundred and twenty four (38%) of pharmacist surveys were completed and returned. Principal component analysis suggested removal of 1 item for a final 1-factor solution. The refined 10-item FICI-P demonstrated internal consistency reliability at Cronbach's alpha=0.90. After collapsing the original 5-point response scale to a 4-point response scale, the refined FICI-P demonstrated fit to the Rasch model. Criterion validity of the FICI-P was supported by the correlation of FICI-P scores with scores on a previously validated Physician-Pharmacist Collaboration Instrument. Validity was also supported by predicted differences in FICI-P scores between subgroups of respondents stratified on age, colocation with GPs, and interactions during the intern-training period. The refined 10-item FICI-P was shown to have good internal consistency, criterion validity, and fit to the Rasch model. The creation of such a tool may allow for the measure of impact in the evaluation of interventions designed to improve interprofessional collaboration between GPs and pharmacists. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. ECLSS Integration Analysis: Advanced ECLSS Subsystem and Instrumentation Technology Study for the Space Exploration Initiative

    Science.gov (United States)

    1990-01-01

    In his July 1989 space policy speech, President Bush proposed a long range continuing commitment to space exploration and development. Included in his goals were the establishment of permanent lunar and Mars habitats and the development of extended duration space transportation. In both cases, a major issue is the availability of qualified sensor technologies for use in real-time monitoring and control of integrated physical/chemical/biological (p/c/b) Environmental Control and Life Support Systems (ECLSS). The purpose of this study is to determine the most promising instrumentation technologies for future ECLSS applications. The study approach is as follows: 1. Precursor ECLSS Subsystem Technology Trade Study - A database of existing and advanced Atmosphere Revitalization (AR) and Water Recovery and Management (WRM) ECLSS subsystem technologies was created. A trade study was performed to recommend AR and WRM subsystem technologies for future lunar and Mars mission scenarios. The purpose of this trade study was to begin defining future ECLSS instrumentation requirements as a precursor to determining the instrumentation technologies that will be applicable to future ECLS systems. 2. Instrumentation Survey - An instrumentation database of Chemical, Microbial, Conductivity, Humidity, Flowrate, Pressure, and Temperature sensors was created. Each page of the sensor database report contains information for one type of sensor, including a description of the operating principles, specifications, and the reference(s) from which the information was obtained. This section includes a cursory look at the history of instrumentation on U.S. spacecraft. 3. Results and Recommendations - Instrumentation technologies were recommended for further research and optimization based on a consideration of both of the above sections. A sensor or monitor technology was recommended based on its applicability to future ECLS systems, as defined by the ECLSS Trade Study (1), and on whether its

  4. Reactor instrumentation and control

    International Nuclear Information System (INIS)

    Wach, D.; Beraha, D.

    1980-01-01

    The methods for measuring radiation are shortly reviewed. The instrumentation for neutron flux measurement is classified into out-of-core and in-core instrumentation. The out-of-core instrumentation monitors the operational range from the subcritical reactor to full power. This large range is covered by several measurement channels which derive their signals from counter tubes and ionization chambers. The in-core instrumentation provides more detailed information on the power distribution in the core. The self-powered neutron detectors and the aeroball system in PWR reactors are discussed. Temperature and pressure measurement devices are briefly discussed. The different methods for leak detection are described. In concluding the plant instrumentation part some new monitoring systems and analysis methods are presented: early failure detection methods by noise analysis, acoustic monitoring and vibration monitoring. The presentation of the control starts from an qualitative assessment of the reactor dynamics. The chosen control strategy leads to the definition of the part-load diagram, which provides the set-points for the different control systems. The tasks and the functions of these control systems are described. In additiion to the control, a number of limiting systems is employed to keep the reactor in a safe operating region. Finally, an outlook is given on future developments in control, concerning mainly the increased application of process computers. (orig./RW)

  5. Isotope-equipped measuring instruments

    International Nuclear Information System (INIS)

    Miyagawa, Kazuo; Amano, Hiroshi

    1980-01-01

    In the steel industry, though the investment in isotope-equipped measuring instruments is small as compared with that in machinery, they play important role in the moisture measurement in sintering and blast furnaces, the thickness measurement in rolling process and others in automatic control systems. The economic aspect of the isotope-equipped measuring instruments is described on the basis of the practices in Kimitsu Works of Nippon Steel Corporation: distribution of such instruments, evaluation of economic effects, usefulness evaluation in view of raising the accuracy, and usefulness evaluation viewed from the failure of the isotope instruments. The evaluation of economic effects was made under the premise that the isotope-equipped measuring instruments are not employed. Then, the effects of raising the accuracy are evaluated for a γ-ray plate thickness gauge and a neutron moisture gauge for coke in a blast furnace. Finally, the usefulness was evaluated, assuming possible failure of the isotope-equipped measuring instruments. (J.P.N.)

  6. Analysis of instrumentation technology for SMART

    International Nuclear Information System (INIS)

    Hur, Seop; Koo, I. S.; Park, H. Y.; Lee, C. K.; Kim, D. H.; Suh, Y. S.; Seong, S. H.; Jang, G. S.

    1998-03-01

    It is necessary that development requirements, techniques to be developed, and development tasks and approach are established to develop the SMART instrumentation system. It is important to establish the development strategies for input for developing SMART instrumentation system. To meet above needs, the industry general and nuclear instrumentation techniques were analyzed and reviewed, respectively, based on the classification of instrumentation to analyze the industrial instrumentation techniques, and analysis results which described the inherent merits and demerits of each technique can be used for inputs to select the instruments for SMART. For the instrumentation techniques for nuclear environments, the major instrumentation techniques were reviewed, and the instrumentation system were established. The following development approaches were established based on the development requirements and the analysis results of research and development trends of industrial and nuclear instrumentation techniques. (author). 90 refs., 38 tabs., 33 figs

  7. Regulatory requirements on the calibration and use of survey instruments

    International Nuclear Information System (INIS)

    Domondon, D.B.

    1989-01-01

    Regulatory requirements on the provision, calibration and occasions of use of survey instruments are enumerated for a number of licensed activities. Two methods of calibrating survey instruments are described. Factors that must be taken into consideration in conducting calibrations, contents of calibration reports and of the sticker attached to the instrument which are needed for the correct use of the instrument are discussed. The precautions to be observed in order to insure correct use of survey instruments are described. (Auth.)

  8. Measurement, instrumentation, and sensors handbook

    CERN Document Server

    Eren, Halit

    2014-01-01

    The Second Edition of the bestselling Measurement, Instrumentation, and Sensors Handbook brings together all aspects of the design and implementation of measurement, instrumentation, and sensors. Reflecting the current state of the art, it describes the use of instruments and techniques for performing practical measurements in engineering, physics, chemistry, and the life sciences and discusses processing systems, automatic data acquisition, reduction and analysis, operation characteristics, accuracy, errors, calibrations, and the incorporation of standards for control purposes. Organized acco

  9. Cascadia Initiative Ocean Bottom Seismograph Performance

    Science.gov (United States)

    Evers, B.; Aderhold, K.

    2017-12-01

    The Ocean Bottom Seismograph Instrument Pool (OBSIP) provided instrumentation and operations support for the Cascadia Initiative community experiment. This experiment investigated geophysical processes across the Cascadia subduction zone through a combination of onshore and offshore seismic data. The recovery of Year 4 instruments in September 2015 marked the conclusion of a multi-year experiment that utilized 60 ocean-bottom seismographs (OBSs) specifically designed for the subduction zone boundary, including shallow/deep water deployments and active fisheries. The new instruments featured trawl-resistant enclosures designed by Lamont-Doherty Earth Observatory (LDEO) and Scripps Institution of Oceanography (SIO) for shallow deployment [water depth ≤ 500 m], as well as new deep-water instruments designed by Woods Hole Oceanographic Institute (WHOI). Existing OBSIP instruments were also deployed along the Blanco Transform Fault and on the Gorda Plate through complementary experiments. Station instrumentation included weak and strong motion seismometers, differential pressure gauges (DPG) and absolute pressure gauges (APG). All data collected from the Cascadia, Blanco, and Gorda deployments is available through the Incorporated Research Institutions for Seismology (IRIS) Data Management Center (DMC). The Cascadia Initiative is the largest amphibious seismic experiment undertaken to date, encompassing a diverse technical implementation and demonstrating an effective structure for community experiments. Thus, the results from Cascadia serve as both a technical and operational resource for the development of future community experiments, such as might be contemplated as part of the SZ4D Initiative. To guide future efforts, we investigate and summarize the quality of the Cascadia OBS data using basic metrics such as instrument recovery and more advanced metrics such as noise characteristics through power spectral density analysis. We also use this broad and diverse

  10. 2H Evaporator CP class instrumentation uncertainties evaluations

    International Nuclear Information System (INIS)

    Hwang, E.

    1994-01-01

    The Evaporator Pot Temperature Instrumentations and the Steam Condensate Gamma Monitors are two instrumentation systems in the 2H Evaporator facilities that are classified as the critical protection. The temperature high alarm and interlock circuit and the temperature recorder circuit of the pot temperature instrumentation loop are described. From the gamma monitor loop, the high gamma alarm and interlock circuit, failure alarm and interlock circuit, cesium activity recorder circuit, and americium activity recorder circuit are described

  11. 2H Evaporator CP class instrumentation uncertainties evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, E.

    1994-02-10

    The Evaporator Pot Temperature Instrumentations and the Steam Condensate Gamma Monitors are two instrumentation systems in the 2H Evaporator facilities that are classified as the critical protection. The temperature high alarm and interlock circuit and the temperature recorder circuit of the pot temperature instrumentation loop are described. From the gamma monitor loop, the high gamma alarm and interlock circuit, failure alarm and interlock circuit, cesium activity recorder circuit, and americium activity recorder circuit are described. (GHH)

  12. A Finescale Lagrangian Instrument System

    National Research Council Canada - National Science Library

    Toole, John

    2003-01-01

    ... from conventional, bottom-anchored moorings. An initial trial of the concept targeting the upper ocean was carried out off Bermuda in November 2001 with an instrument profiling between 12 and 28O-m depth...

  13. Atomic absorption instrument functional description

    International Nuclear Information System (INIS)

    Bystroff, R.I.; Boyle, W.G. Jr.; Barton, G.W. Jr.

    1976-01-01

    This report describes a proposed system for automating atomic absorption analysis. The system consists of two atomic absorption instruments and an automatic sampler that can be attached to either instrument. A computer program controls the sampling and gathers data. The program then uses the data to perform bookkeeping, data processing, and report writing

  14. A Database Management Assessment Instrument

    Science.gov (United States)

    Landry, Jeffrey P.; Pardue, J. Harold; Daigle, Roy; Longenecker, Herbert E., Jr.

    2013-01-01

    This paper describes an instrument designed for assessing learning outcomes in data management. In addition to assessment of student learning and ABET outcomes, we have also found the instrument to be effective for determining database placement of incoming information systems (IS) graduate students. Each of these three uses is discussed in this…

  15. Pre-flight calibration and initial data processing for the ChemCam laser-induced breakdown spectroscopy instrument on the Mars Science Laboratory rover

    Energy Technology Data Exchange (ETDEWEB)

    Wiens, R.C., E-mail: rwiens@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM 87544 (United States); Maurice, S.; Lasue, J.; Forni, O. [Institut de Recherche en Astrophysique et Planetologie, Toulouse (France); Anderson, R.B. [United States Geological Survey, Flagstaff, AZ (United States); Clegg, S. [Los Alamos National Laboratory, Los Alamos, NM 87544 (United States); Bender, S. [Planetary Science Institute, Tucson, AZ (United States); Blaney, D. [Jet Propulsion Laboratory, Pasadena, CA (United States); Barraclough, B.L. [Planetary Science Institute, Tucson, AZ (United States); Cousin, A. [Los Alamos National Laboratory, Los Alamos, NM 87544 (United States); Institut de Recherche en Astrophysique et Planetologie, Toulouse (France); Deflores, L. [Jet Propulsion Laboratory, Pasadena, CA (United States); Delapp, D. [Los Alamos National Laboratory, Los Alamos, NM 87544 (United States); Dyar, M.D. [Mount Holyoke College, South Hadley, MA (United States); Fabre, C. [Georessources, Nancy (France); Gasnault, O. [Institut de Recherche en Astrophysique et Planetologie, Toulouse (France); Lanza, N. [Los Alamos National Laboratory, Los Alamos, NM 87544 (United States); Mazoyer, J. [LESIA, Observatoire de Paris, Meudon (France); Melikechi, N. [Delaware State University, Dover, DE (United States); Meslin, P.-Y. [Institut de Recherche en Astrophysique et Planetologie, Toulouse (France); Newsom, H. [University of New Mexico, Albuquerque, NM (United States); and others

    2013-04-01

    The ChemCam instrument package on the Mars Science Laboratory rover, Curiosity, is the first planetary science instrument to employ laser-induced breakdown spectroscopy (LIBS) to determine the compositions of geological samples on another planet. Pre-processing of the spectra involves subtracting the ambient light background, removing noise, removing the electron continuum, calibrating for the wavelength, correcting for the variable distance to the target, and applying a wavelength-dependent correction for the instrument response. Further processing of the data uses multivariate and univariate comparisons with a LIBS spectral library developed prior to launch as well as comparisons with several on-board standards post-landing. The level-2 data products include semi-quantitative abundances derived from partial least squares regression. A LIBS spectral library was developed using 69 rock standards in the form of pressed powder disks, glasses, and ceramics to minimize heterogeneity on the scale of the observation (350–550 μm dia.). The standards covered typical compositional ranges of igneous materials and also included sulfates, carbonates, and phyllosilicates. The provenance and elemental and mineralogical compositions of these standards are described. Spectral characteristics of this data set are presented, including the size distribution and integrated irradiances of the plasmas, and a proxy for plasma temperature as a function of distance from the instrument. Two laboratory-based clones of ChemCam reside in Los Alamos and Toulouse for the purpose of adding new spectra to the database as the need arises. Sensitivity to differences in wavelength correlation to spectral channels and spectral resolution has been investigated, indicating that spectral registration needs to be within half a pixel and resolution needs to match within 1.5 to 2.6 pixels. Absolute errors are tabulated for derived compositions of each major element in each standard using PLS regression

  16. Radiation protection commissioning of neutron beam instruments at the OPAL research reactor

    International Nuclear Information System (INIS)

    Parkes, Alison; Saratsopoulos, John; Deura, Michael; Kenny, Pat

    2008-01-01

    The neutron beam facilities at the 20 MW OPAL Research Reactor were commissioned in 2007 and 2008. The initial suite of eight neutron beam instruments on two thermal neutron guides, two cold neutron guides and one thermal beam port located at the reactor face, together with their associated shielding were progressively installed and commissioned according to their individual project plans. Radiation surveys were systematically conducted as reactor power was raised in a step-wise manner to 20 MW in order to validate instrument shielding design and performance. The performance of each neutron guide was assessed by neutron energy spectrum and flux measurements. The activation of beam line components, decay times assessments and access procedures for Bragg Institute beam instrument scientists were established. The multiple configurations for each instrument and the influence of operating more than one instrument or beamline simultaneously were also tested. Areas of interest were the shielding around the secondary shutters, guide shield and bunker shield interfaces and monochromator doors. The shielding performance, safety interlock checks, improvements, radiation exposures and related radiation protection challenges are discussed. This paper discusses the health physics experience of commissioning the OPAL Research Reactor neutron beam facilities and describes health physics results, actions taken and lessons learned during commissioning. (author)

  17. The Development of a Survey Instrument on South Dakota's School District Leadership Climate as Related to Deming's Fourteen Points.

    Science.gov (United States)

    Holmes, Lawrence W. O.; And Others

    Development of an instrument to measure baseline levels of applied Total Quality Management (TQM) practices in South Dakota before the introduction and dissemination of TQM theory to the state's educational leaders is described. Using the interpretation of Deming's 14 points that was developed by J. J. Bonstigl, a 115-item initial item pool was…

  18. Linear Plasma Oscillation Described by Superposition of Normal Modes

    DEFF Research Database (Denmark)

    Pécseli, Hans

    1974-01-01

    The existence of steady‐state solutions to the linearized ion and electron Vlasov equation is demonstrated for longitudinal waves in an initially stable plasma. The evolution of an arbitrary initial perturbation can be described by superposition of these solutions. Some common approximations...

  19. Initial results from beam commissioning of the LHC beam dump system

    CERN Document Server

    Goddard, B; Carlier, E; Ducimetière, L; Gallet, E; Gyr, M; Jensen, L; Jones, R; Kain, V; Kramer, T; Lamont, M; Meddahi, M; Mertens, V; Risselada, Thys; Uythoven, J; Wenninger, J; Weterings, W

    2010-01-01

    Initial commissioning of the LHC beam dump system with beam took place in August and September 2008. The preparation, setting-up and the tests performed are described together with results of the extractions of beam into the dump lines. Analysis of the first detailed aperture measurements of the extraction channels and kicker performance derived from dilution sweep shapes are presented. The performance of the other equipment subsystems is summarised, in particular that of the dedicated dump system beam instrumentation.

  20. Critical Science Instrument Alignment of the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM)

    Science.gov (United States)

    Rohrbach, Scott O.; Kubalak, David A.; Gracey, Renee M.; Sabatke, Derek S.; Howard, Joseph M.; Telfer, Randal C.; Zielinski, Thomas P.

    2016-01-01

    This paper describes the critical instrument alignment terms associated with the six-degree of freedom alignment of each the Science Instrument (SI) in the James Webb Space Telescope (JWST), including focus, pupil shear, pupil clocking, and boresight. We present the test methods used during cryogenic-vacuum tests to directly measure the performance of each parameter, the requirements levied on each, and the impact of any violations of these requirements at the instrument and Observatory level.

  1. Measurement techniques and instruments suitable for life-prediction testing of photovoltaic arrays. Interim report

    Energy Technology Data Exchange (ETDEWEB)

    Noel, G.T.; Sliemers, F.A.; Deringer, G.C.; Wood, V.E.; Wilkes, K.E.; Gaines, G.B.; Carmichael, D.C.

    1978-01-15

    The validation of a service life of 20 years for low-cost photovoltaic arrays must be accomplished through accelerated life-prediction tests. A methodology for such tests has been developed in a preceding study. The results discussed consist of the initial identification and assessment of all known measurement techniques and instruments that might be used in these life-prediction tests. Array failure modes, relevant materials property changes, and primary degradation mechanisms are discussed as a prerequisite to identifying suitable measurement techniques and instruments. Candidate techniques and instruments are identified on the basis of extensive reviews of published and unpublished information. These methods are organized in six measurement categories--chemical, electrical, optical, thermal, mechanical, and ''other physicals''. Using specified evaluation criteria, the most promising techniques and instruments for use in life-prediction tests of arrays are then selected. These recommended techniques and their characteristics are described. Recommendations are made regarding establishment of the adequacy, particularly with respect to precision, of the more fully developed techniques for this application, and regarding the experimental evaluation of promising developmental techniques. Measurement needs not satisfied by presently available techniques/instruments are also identified.

  2. Initial results from the fast imaging solar spectrograph (FISS)

    CERN Document Server

    2015-01-01

    This collection of papers describes the instrument and initial results obtained from the Fast Imaging Solar Spectrograph (FISS),  one of the post-focus instruments of the 1.6 meter New Solar Telescope at the Big Bear Solar Observatory. The FISS primarily aims at investigating structures and dynamics of  chromospheric features. This instrument is a dual-band Echelle spectrograph optimized for the simultaneous recording of the H I 656.3 nm band and the Ca II 854.2 nm band. The imaging is done with the fast raster scan realized by the linear motion of a two-mirror scanner, and its quality is determined by the performance of the adaptive optics of the telescope.    These papers illustrate the capability of the early FISS observations in the study of chromospheric features. Since the imaging quality has been improved a lot with the advance of the adaptive optics, one can obtain much better data with the current FISS observations.        This volume is aimed at graduate students and researchers working in...

  3. Traceability of radiation protection instruments

    Science.gov (United States)

    Hino, Y.; Kurosawa, T.

    2007-08-01

    Radiation protection instruments are used in daily measurement of dose and activities in workplaces and environments for safety management. The requirements for calibration certificates with traceability are increasing for these instruments to ensure the consistency and reliabilities of the measurement results. The present traceability scheme of radiation protection instruments for dose and activity measurements is described with related IEC/ISO requirements. Some examples of desirable future calibration systems with recent new technologies are also discussed to establish the traceability with reasonable costs and reliabilities.

  4. Steam 80 steam generator instrumentation

    International Nuclear Information System (INIS)

    Carson, W.H.; Harris, H.H.

    1980-01-01

    This paper describes two special instrumentation packages in an integral economizer (preheater) steam generator of one of the first System 80 plants scheduled to go into commercial operation. The purpose of the instrumentation is to obtain accurate operating information from regions of the secondary side of the steam generator inaccessible to normal plant instrumentation. In addition to verification of the System 80 steam generator design predictions, the data obtained will assist in verification of steam generator thermal/hydraulic computer codes developed for generic use in the industry

  5. Laboratory for Calibration of Gamma Radiation Measurement Instruments (LabCal) of Institute of Chemical, Biological, Radiological and Nuclear Defense (IDQBRN) from Brazilian Army Technology Center (CTEx)

    International Nuclear Information System (INIS)

    Amorim, Aneuri de; Balthar, Mario Cesar V.; Santos, Avelino; Vilela, Paulo Ricardo T. de; Oliveira, Luciano Santa Rita; Penha, Paulo Eduardo C. de Oliveira; Gonzaga, Roberto Neves; Andrade, Edson Ramos de; Oliveira, Celio Jorge Vasques de; Fagundes, Luiz Cesar S.

    2016-01-01

    This paper describes the calibration laboratory deployment steps (LABCAL) gamma ionizing radiation measuring instruments in the Army Technology Center, CTEx. Initially the calibration of radiation monitors will be held in the dosimetric quantity air kerma and operational quantity ambient dose equivalent H*(d). The LABCAL / CTEx has not yet authorized by CASEC / CNEN. This laboratory aims to calibrate the ionizing radiation instruments used by the Brazilian Army. (author)

  6. Report of the Instrumentation Service - Annex C

    International Nuclear Information System (INIS)

    Majstorovic, D.

    1987-01-01

    This report describes the tasks and organizational structure of the Instrumentation service. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment related to experimental facilities [sr

  7. Augmenting traditional instruments with a motion capture system

    DEFF Research Database (Denmark)

    Götzen, Amalia De; Vidolin, Alvise; Bernardini, Nicola

    2013-01-01

    This paper describes some composition works where the real instruments have been augmented through a motion capture system (Phasespace). While playing his instrument in the traditional way, the player is also controlling some other sound effects by moving his hands: the instrument becomes totally...

  8. Portable radiation instrumentation traceability of standards and measurements

    International Nuclear Information System (INIS)

    Wiserman, A.; Walke, M.

    1995-01-01

    Portable radiation measuring instruments are used to estimate and control doses for workers. Calibration of these instruments must be sufficiently accurate to ensure that administrative and legal dose limits are not likely to be exceeded due to measurement uncertainties. An instrument calibration and management program is established which permits measurements made with an instrument to be traced to a national standard. This paper describes the establishment and maintenance of calibration standards for gamma survey instruments and an instrument management program which achieves traceability of measurement for uniquely identified field instruments. (author)

  9. Performance Monitoring for Nuclear Safety Related Instrumentation at PUSPATI TRIGA Reactor (RTP)

    International Nuclear Information System (INIS)

    Zareen Khan Abdul Jalil Khan; Ridzuan Abdul Mutalib; Mohd Sabri Minhat

    2015-01-01

    The Reactor TRIGA PUSPATI (RTP) at Malaysia Nuclear Agency is a TRIGA Mark II type reactor and pool type cooled by natural circulation of light water. This paper describe on performance monitoring for nuclear safety related instrumentation in TRIGA PUSPATI Reactor (RTP) of based on various parameter of reactor safety instrument channel such as log power, linear power, Fuel temperature, coolant temperature will take into consideration. Methodology of performance on estimation and monitoring is to evaluate and analysis of reactor parameters which is important of reactor safety and control. And also to estimate power measurement, differential of log and linear power and fuel temperature during reactor start-up, operation and shutdown .This study also focus on neutron power fluctuation from fission chamber during reactor start-up and operation. This work will present result of performance monitoring from RTP which indicated the safety parameter identification and initiate safety action on crossing the threshold set point trip. Conclude that performance of nuclear safety related instrumentation will improved the reactor control and safety parameter during reactor start-up, operation and shutdown. (author)

  10. Beam Instrumentation Global Network [BIGNET]: a common web portal for Beam instrumentalists

    CERN Document Server

    Gras, J-J

    2012-01-01

    This document will present an initiative launched during the International Particle Accelerator Conference (IPAC11) to define and produce a common web portal for Beam Instrumentation, with the aim of allowing any beam instrumentalist to easily and efficiently: - find the laboratories with machines using beams of similar characteristics (particle type, total beam intensity, bunch intensity, frequency, energy) - find the person who is working there on the beam observable concerned (i.e. beam position, loss, intensity, transverse or longitudinal profile, tune) and how to contact him/her - create discussion forums with the right audience on hot beam instrumentation topics or issues - advertise topical events and workshop - provide links towards documents describing system designs and performance assessments... This document will cover the status and prospects of the project with the aim to invite and welcome new laboratories to join the adventure.

  11. Describing the Climate of Student Organizations: The Student Organization Environment Scales.

    Science.gov (United States)

    Winston, Roger B., Jr.; Bledsoe, Tyrone; Goldstein, Adam R.; Wisbey, Martha E.; Street, James L.; Brown, Steven R.; Goyen, Kenneth D.; Rounds, Linda E.

    1997-01-01

    Using M. R. Weisbord's model of organizational diagnosis, researchers developed the Student Organization Environment Scales to measure students' perceptions of the psychosocial environment or climate of college student organizations. Development of the instrument is described and estimates of its reliability and validity are reported. Describes…

  12. Performance of BATAN-SANS instrument

    Energy Technology Data Exchange (ETDEWEB)

    Ikram, Abarrul; Insani, Andon [National Nuclear Energy Agency, P and D Centre for Materials Science and Technology, Serpong (Indonesia)

    2003-03-01

    SANS data from some standard samples have been obtained using BATAN-SANS instrument in Serpong. The experiments were performed for various experimental set-ups that involve different detector positions and collimator lengths. This paper describes the BATAN-SANS instrument briefly as well as the data taken from those experiments and followed with discussion of the results concerning the performance and calibration of the instrument. The standard samples utilized in these experiments include porous silica, polystyrene-poly isoprene, silver behenate, poly ball and polystyrene-poly (ethylene-alt-propylene). Even though the results show that BATAN-SANS instrument is in good shape, but rooms for improvements are still widely open especially for the velocity selector and its control system. (author)

  13. Multi-Institutional Development of a Mastoidectomy Performance Evaluation Instrument.

    Science.gov (United States)

    Kerwin, Thomas; Hittle, Brad; Stredney, Don; De Boeck, Paul; Wiet, Gregory

    A method for rating surgical performance of a mastoidectomy procedure that is shown to apply universally across teaching institutions has not yet been devised. This work describes the development of a rating instrument created from a multi-institutional consortium. Using a participatory design and a modified Delphi approach, a multi-institutional group of expert otologists constructed a 15-element task-based checklist for evaluating mastoidectomy performance. This instrument was further refined into a 14-element checklist focusing on the concept of safety after using it to rate a large and varied population of performances. Twelve otolaryngological surgical training programs in the United States. A total of 14 surgeons from 12 different institutions took part in the construction of the instrument. By using 14 experts from 12 different institutions and a literature review, individual metrics were identified, rated as to the level of importance and operationally defined to create a rating scale for mastoidectomy performance. Initial use of the rating scale showed modest rater agreement. The operational definitions of individual metrics were modified to emphasize "safe" as opposed to "proper" technique. A second rating instrument was developed based on this feedback. Using a consensus-building approach with multiple rounds of communication between experts is a feasible way to construct a rating instrument for mastoidectomy. Expert opinion alone using a Delphi method provides face and content validity evidence, however, this is not sufficient to develop a universally acceptable rating instrument. A continued process of development and experimentation to demonstrate evidence for reliability and validity making use of a large population of raters and performances is necessary to achieve universal acceptance. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  14. Tool – Material, Metaphor – Metonymy, Instrument(ness)

    DEFF Research Database (Denmark)

    Bertelsen, Olav Wedege; Breinbjerg, Morten; Pold, Søren

    2008-01-01

    creativity , supported by analysis of, and interviews with, musical composers. Instrumentness is explained through discussions of materiality and metonymy as central strategies for computer mediated creativity. The paper is contributing to an investigation of the aesthetics of use in relation to software...... are controlled and conceptualized through values such as virtuosity and palyability, which are important for computer-mediated creative work supporting development in use beyond what is initially designed for. The papet performs a conceptual investigation into qualities in software interfaces that support...

  15. Development and initial validation of the Parental PELICAN Questionnaire (PaPEQu)--an instrument to assess parental experiences and needs during their child's end-of-life care.

    Science.gov (United States)

    Zimmermann, Karin; Cignacco, Eva; Eskola, Katri; Engberg, Sandra; Ramelet, Anne-Sylvie; Von der Weid, Nicolas; Bergstraesser, Eva

    2015-12-01

    To develop and test the Parental PELICAN Questionnaire, an instrument to retrospectively assess parental experiences and needs during their child's end-of-life care. To offer appropriate care for dying children, healthcare professionals need to understand the illness experience from the family perspective. A questionnaire specific to the end-of-life experiences and needs of parents losing a child is needed to evaluate the perceived quality of paediatric end-of-life care. This is an instrument development study applying mixed methods based on recommendations for questionnaire design and validation. The Parental PELICAN Questionnaire was developed in four phases between August 2012-March 2014: phase 1: item generation; phase 2: validity testing; phase 3: translation; phase 4: pilot testing. Psychometric properties were assessed after applying the Parental PELICAN Questionnaire in a sample of 224 bereaved parents in April 2014. Validity testing covered the evidence based on tests of content, internal structure and relations to other variables. The Parental PELICAN Questionnaire consists of approximately 90 items in four slightly different versions accounting for particularities of the four diagnostic groups. The questionnaire's items were structured according to six quality domains described in the literature. Evidence of initial validity and reliability could be demonstrated with the involvement of healthcare professionals and bereaved parents. The Parental PELICAN Questionnaire holds promise as a measure to assess parental experiences and needs and is applicable to a broad range of paediatric specialties and settings. Future validation is needed to evaluate its suitability in different cultures. © 2015 John Wiley & Sons Ltd.

  16. Computer-Aided Instruction in Automated Instrumentation.

    Science.gov (United States)

    Stephenson, David T.

    1986-01-01

    Discusses functions of automated instrumentation systems, i.e., systems which combine electrical measuring instruments and a controlling computer to measure responses of a unit under test. The computer-assisted tutorial then described is programmed for use on such a system--a modern microwave spectrum analyzer--to introduce engineering students to…

  17. Enhanced in-pile instrumentation at the advanced test reactor

    Energy Technology Data Exchange (ETDEWEB)

    Rempe, J. L.; Knudson, D. L.; Daw, J. E.; Unruh, T.; Chase, B. M.; Palmer, J.; Condie, K. G.; Davis, K. L. [Idaho National Laboratory, MS 3840, P.O. Box 1625, Idaho Falls, ID 83415 (United States)

    2011-07-01

    Many of the sensors deployed at materials and test reactors cannot withstand the high flux/high temperature test conditions often requested by users at U.S. test reactors, such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory. To address this issue, an instrumentation development effort was initiated as part of the ATR National Scientific User Facility in 2007 to support the development and deployment of enhanced in-pile sensors. This paper reports results from this effort. Specifically, this paper identifies the types of sensors currently available to support in-pile irradiations and those sensors currently available to ATR users. Accomplishments from new sensor technology deployment efforts are highlighted by describing new temperature and thermal conductivity sensors now available to ATR users. Efforts to deploy enhanced in-pile sensors for detecting elongation and realtime flux detectors are also reported, and recently-initiated research to evaluate the viability of advanced technologies to provide enhanced accuracy for measuring key parameters during irradiation testing are noted. (authors)

  18. Enhanced In-Pile Instrumentation at the Advanced Test Reactor

    Science.gov (United States)

    Rempe, Joy L.; Knudson, Darrell L.; Daw, Joshua E.; Unruh, Troy; Chase, Benjamin M.; Palmer, Joe; Condie, Keith G.; Davis, Kurt L.

    2012-08-01

    Many of the sensors deployed at materials and test reactors cannot withstand the high flux/high temperature test conditions often requested by users at U.S. test reactors, such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory. To address this issue, an instrumentation development effort was initiated as part of the ATR National Scientific User Facility in 2007 to support the development and deployment of enhanced in-pile sensors. This paper provides an update on this effort. Specifically, this paper identifies the types of sensors currently available to support in-pile irradiations and those sensors currently available to ATR users. Accomplishments from new sensor technology deployment efforts are highlighted by describing new temperature and thermal conductivity sensors now available to ATR users. Efforts to deploy enhanced in-pile sensors for detecting elongation and real-time flux detectors are also reported, and recently-initiated research to evaluate the viability of advanced technologies to provide enhanced accuracy for measuring key parameters during irradiation testing are noted.

  19. Impact Disdrometers Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Bartholomew, Mary Jane [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-03-01

    To improve the quantitative description of precipitation processes in climate models, the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Climate Research Facility has been collecting observations of the drop size spectra of rain events since early in 2006. Impact disdrometers were the initial choice due to their reliability, ease of maintenance, and relatively low cost. Each of the two units deployed was accompanied by a nearby tipping bucket. In 2010, the tipping buckets were replaced by weighing buckets rain gauges. Five video disdrometers were subsequently purchased and are described in ARM’s VDIS Handbook.1 As of April 2011, three of the weighing bucket instruments were deployed, one was to travel with the second ARM Mobile Facility, and the fifth was a spare. Two of the video disdrometers were deployed, a third was to be deployed later in the spring of 2011, one was to travel with the second ARM Mobile Facility, and the last was a spare. Detailed descriptions of impact disdrometers and their datastreams are provided in this document.

  20. Remote Monitoring of Instrumentation in Sealed Compartments

    International Nuclear Information System (INIS)

    Landron, Clinton; Moser, John C.

    1999-01-01

    The Instrumentation and Telemetry Departments at Sandia National Laboratories have been exploring the instrumentation of sealed canisters where the flight application will not tolerate either the presence of a chemical power source or penetration by power supply wires. This paper will describe the application of a low power micro-controller based instrumentation system that uses magnetic coupling for both power and data to support a flight application

  1. A comparison of instrumentation using Naviflex and Profile nickel-titanium engine-driven rotary instruments.

    Science.gov (United States)

    Ottosen, S R; Nicholls, J I; Steiner, J C

    1999-06-01

    This study was designed to compare the changes in canal configuration resulting from instrumentation by either Profile or Naviflex instruments. Forty mesial canals in extracted human molar teeth were embedded and sectioned at two root levels. Reassembled teeth were instrumented with a modified crown-down technique as described in the Profile training video for Profile files and in a similar manner for Naviflex instruments. Superimposed pre- and postinstrumented cross-sectional root images were projected, traced, and scanned into a computer for analysis. Canal movement, in relation to the furca, and canal area change were recorded. The results showed no significant difference in canal center movement or canal area change between the Profile or Naviflex groups. The degree of canal curvature had no effect on canal center movement or canal area change.

  2. Standard practice for evaluating performance characteristics of ultrasonic Pulse-Echo testing instruments and systems without the use of electronic measurement instruments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This practice describes procedures for evaluating the following performance characteristics of ultrasonic pulse-echo examination instruments and systems: Horizontal Limit and Linearity; Vertical Limit and Linearity; Resolution - Entry Surface and Far Surface; Sensitivity and Noise; Accuracy of Calibrated Gain Controls. Evaluation of these characteristics is intended to be used for comparing instruments and systems or, by periodic repetition, for detecting long-term changes in the characteristics of a given instrument or system that may be indicative of impending failure, and which, if beyond certain limits, will require corrective maintenance. Instrument characteristics measured in accordance with this practice are expressed in terms that relate to their potential usefulness for ultrasonic testing. Instrument characteristics expressed in purely electronic terms may be measured as described in E1324. 1.2 Ultrasonic examination systems using pulsed-wave trains and A-scan presentation (rf or video) may be ev...

  3. Nuclear instrumentation for radiation measurement

    International Nuclear Information System (INIS)

    Madan, V.K.

    2012-01-01

    Nuclear radiation cannot be detected by human senses. Nuclear detectors and associated electronics facilitate detection and measurement of different types of radiation like alpha particles, beta particles, gamma radiation, and detection of neutrons. Nuclear instrumentation has evolved greatly since the discovery of radioactivity. There has been tremendous advancement in detector technology, electronics, computer technology, and development of efficient algorithms and methods for spectral processing to extract precisely qualitative and quantitative information of the radiation. Various types of detectors and nuclear instruments are presently available and are used for different applications. This paper describes nuclear radiation, its detection and measurement and associated electronics, spectral information extraction, and advances in these fields. The paper also describes challenges in this field

  4. Ion chamber instrument

    International Nuclear Information System (INIS)

    Stephan, D.H.

    1975-01-01

    An electrical ionization chamber is described having a self-supporting wall of cellular material which is of uniform areal density and formed of material, such as foamed polystyrene, having an average effective atomic number between about 4 and about 9, and easily replaceable when on the instrument. (auth)

  5. Imperative-program transformation by instrumented-interpreter specialization

    DEFF Research Database (Denmark)

    Debois, Søren

    2008-01-01

    We describe how to implement strength reduction, loop-invariant code motion and loop quasi-invariant code motion by specializing instrumented interpreters. To curb code duplication intrinsic to such specialization, we introduce a new program transformation, rewinding, which uses Moore-automata mi......We describe how to implement strength reduction, loop-invariant code motion and loop quasi-invariant code motion by specializing instrumented interpreters. To curb code duplication intrinsic to such specialization, we introduce a new program transformation, rewinding, which uses Moore...

  6. Quality control of nuclear medicine instruments

    International Nuclear Information System (INIS)

    1984-11-01

    This document, which gives detailed guidance on the quality control of the various electronic instruments used for radiation detection and measurement in nuclear medicine, stems from the work of two Advisory Groups convened by the International Atomic Energy Agency (IAEA). A preliminary document, including recommended test schedules but lacking actual protocols for the tests, was drawn up by the first of these groups, meeting at the IAEA Headquarters in Vienna in 1979. A revised and extended version, incorporating recommended test protocols, was prepared by the second Group, meeting likewise in Vienna in 1982. This version is the model for the present text. The document should be of value to all nuclear medicine units, and especially to those in developing countries, in the initiation or revision of schemes for the quality control of their instruments. Its recommendations have provided the basis for instruction in two IAEA regional technical co-operation projects in the subject field, one initiated in 1981 for countries of Latin America and one initiated in 1982 for countries of Asia and the Pacific

  7. Economic instruments for environmental policy making in Ontario

    International Nuclear Information System (INIS)

    Barg, S.; Duraiappah, A.; Van Exan, S.

    2000-01-01

    The conditions and approaches required for a successful implementation of economic instruments in Ontario are reviewed. The advantages and disadvantages of economic instruments are discussed, as are some design issues. Some best practices and practical experiences from Canada, the United States, and Europe are examined through the use of nine specific case studies. Each one highlights a different environmental challenge, such as energy efficiency, air pollution, water pollution, waste management along with the solutions that were implemented. The situations described were not all successful, but there is much to be learned from unsuccessful episodes. Lessons learned from the review of the case studies were presented. The points to ponder when using economic instruments in Ontario were highlighted. The command and control policy instrument must be kept in context when considering economic instruments. The reasons that underline the preference of the economic theory for economic instruments are discussed. The different types of economic instruments are described, and the considerations related to the design and comparison of economic instruments is briefly discussed. The authors concluded with several points to ponder: there are a number of options available, details must not be neglected, consultation with the interested parties is important, there is a need for frequent reassessment, and using a number of instruments is helpful. 55 refs., tabs., figs

  8. Direct concurrent comparison of multiple pediatric acute asthma scoring instruments.

    Science.gov (United States)

    Johnson, Michael D; Nkoy, Flory L; Sheng, Xiaoming; Greene, Tom; Stone, Bryan L; Garvin, Jennifer

    2017-09-01

    Appropriate delivery of Emergency Department (ED) treatment to children with acute asthma requires clinician assessment of acute asthma severity. Various clinical scoring instruments exist to standardize assessment of acute asthma severity in the ED, but their selection remains arbitrary due to few published direct comparisons of their properties. Our objective was to test the feasibility of directly comparing properties of multiple scoring instruments in a pediatric ED. Using a novel approach supported by a composite data collection form, clinicians categorized elements of five scoring instruments before and after initial treatment for 48 patients 2-18 years of age with acute asthma seen at the ED of a tertiary care pediatric hospital ED from August to December 2014. Scoring instruments were compared for inter-rater reliability between clinician types and their ability to predict hospitalization. Inter-rater reliability between clinician types was not different between instruments at any point and was lower (weighted kappa range 0.21-0.55) than values reported elsewhere. Predictive ability of most instruments for hospitalization was higher after treatment than before treatment (p < 0.05) and may vary between instruments after treatment (p = 0.054). We demonstrate the feasibility of comparing multiple clinical scoring instruments simultaneously in ED clinical practice. Scoring instruments had higher predictive ability for hospitalization after treatment than before treatment and may differ in their predictive ability after initial treatment. Definitive conclusions about the best instrument or meaningful comparison between instruments will require a study with a larger sample size.

  9. XML in an Adaptive Framework for Instrument Control

    Science.gov (United States)

    Ames, Troy J.

    2004-01-01

    NASA Goddard Space Flight Center is developing an extensible framework for instrument command and control, known as Instrument Remote Control (IRC), that combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML). A key aspect of the architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). IML is an XML dialect used to describe interfaces to control and monitor the instrument, command sets and command formats, data streams, communication mechanisms, and data processing algorithms.

  10. Current capabilities of transient two-phase flow instruments

    International Nuclear Information System (INIS)

    Solbrig, C.W.; Kondic, N.N.

    1979-01-01

    The measurement of two phase flow phenomena in transient conditions representative of a Loss-of-Coolant Accident requires the use of sophisticated instruments and the further development of other instruments. Measurements made in large size pipes are often flow regime dependent. The flow regimes encountered depend upon the system geometry, transient effects, heat transfer, etc. The geometries in which these measurements must be made, the instruments which are currently used, new instruments being developed, the facilities used to calibrate these instruments, and the improvements which must be made to measurement capabilities are described

  11. Notes on instrumentation and control

    CERN Document Server

    Roy, G J

    2013-01-01

    Notes on Instrumentation and Control presents topics on pressure (i.e., U-tube manometers and elastic type gauges), temperature (i.e. glass thermometer, bi-metallic strip thermometer, filled system thermometer, vapor pressure thermometer), level, and flow measuring devices. The book describes other miscellaneous instruments, signal transmitting devices, supply and control systems, and monitoring systems. The theory of automatic control and semi-conductor devices are also considered. Marine engineers will find the book useful.

  12. Methods and instrumentation for quantitative microchip capillary electrophoresis

    NARCIS (Netherlands)

    Revermann, T.

    2007-01-01

    The development of novel instrumentation and analytical methodology for quantitative microchip capillary electrophoresis (MCE) is described in this thesis. Demanding only small quantities of reagents and samples, microfluidic instrumentation is highly advantageous. Fast separations at high voltages

  13. Instrumentation for Air Pollution Monitoring

    Science.gov (United States)

    Hollowell, Craig D.; McLaughlin, Ralph D.

    1973-01-01

    Describes the techniques which form the basis of current commercial instrumentation for monitoring five major gaseous atmospheric pollutants (sulfur dioxide, oxides of nitrogen, oxidants, carbon monoxide, and hydrocarbons). (JR)

  14. Virtual Reality Musical Instruments

    DEFF Research Database (Denmark)

    Serafin, Stefania; Erkut, Cumhur; Kojs, Juraj

    2016-01-01

    The rapid development and availability of low-cost technologies have created a wide interest in virtual reality. In the field of computer music, the term “virtual musical instruments” has been used for a long time to describe software simulations, extensions of existing musical instruments......, and ways to control them with new interfaces for musical expression. Virtual reality musical instruments (VRMIs) that include a simulated visual component delivered via a head-mounted display or other forms of immersive visualization have not yet received much attention. In this article, we present a field...

  15. Fabrication of internally instrumented reactor fuel rods

    International Nuclear Information System (INIS)

    Schmutz, J.D.; Meservey, R.H.

    1975-01-01

    Procedures are outlined for fabricating internally instrumented reactor fuel rods while maintaining the original quality assurance level of the rods. Instrumented fuel rods described contain fuel centerline thermocouples, ultrasonic thermometers, and pressure tubes for internal rod gas pressure measurements. Descriptions of the thermocouples and ultrasonic thermometers are also contained

  16. [The development of an oral biomechanical testing instrument].

    Science.gov (United States)

    Zhang, X H; Sun, X D; Lin, Z

    2000-03-01

    An oral biomechanical testing instrument, which is portable, powered with batteries and controlled by single chip microcomputer, was described. The instrument was characterized by its multichannel, high accuracy, low power dissipation, wide rage of force measurement and stable performance. It can be used for acquisiting, displaying and storing data. And it may be expected to be an ideal instrument for oral biomechanical measurements.

  17. Radiometric well logging instruments

    International Nuclear Information System (INIS)

    Davydov, A.V.

    1975-01-01

    The technical properties of well instruments for radioactive logging used in the radiometric logging complexes PKS-1000-1 (''Sond-1'') and PRKS-2 (''Vitok-2'') are described. The main features of the electric circuit of the measuring channels are given

  18. Design requirements for the SWIFT instrument

    International Nuclear Information System (INIS)

    Rahnama, P; McDade, I; Shepherd, G; Gault, W

    2013-01-01

    The Stratospheric Wind Interferometer for Transport studies (SWIFT) instrument is a proposed limb-viewing satellite instrument that employs the method of Doppler Michelson interferometry to measure stratospheric wind velocities and ozone densities in the altitude range of 15–45 km. The values of the main instrument parameters including filter system parameters and Michelson interferometer parameters are derived using simulations and analyses. The system design requirements for the instrument and spacecraft are presented and discussed. Some of the retrieval-imposed design requirements are also discussed. Critical design issues are identified. The design optimization process is described. The sensitivity of wind measurements to instrument characteristics is investigated including the impact on critical design issues. Using sensitivity analyses, the instrument parameters were iteratively optimized in order to meet the science objectives. It is shown that wind measurements are sensitive to the thermal sensitivity of the instrument components, especially the narrow filter and the Michelson interferometer. The optimized values of the main system parameters including Michelson interferometer optical path difference, instrument visibility, instrument responsivity and knowledge of spacecraft velocity are reported. This work also shows that the filter thermal drift and the Michelson thermal drift are two main technical risks. (paper)

  19. Strengthening the research and development on nursing instruments

    International Nuclear Information System (INIS)

    Liu Lanying; Zhao Changhe

    1999-01-01

    The current status about nursing instruments is described. The nursing work is an impotent part of medical treatments, especially in the treatment with radioactive isotopes. Some proposals concerning the future research and development of nursing instruments have been submitted

  20. Neutron scattering instruments for the Spallation Neutron Source (SNS)

    International Nuclear Information System (INIS)

    Crawford, R.K.; Fornek, T.; Herwig, K.W.

    1998-01-01

    The Spallation Neutron Source (SNS) is a 1 MW pulsed spallation source for neutron scattering planned for construction at Oak Ridge National Laboratory. This facility is being designed as a 5-laboratory collaboration project. This paper addresses the proposed facility layout, the process for selection and construction of neutron scattering instruments at the SNS, the initial planning done on the basis of a reference set of ten instruments, and the plans for research and development (R and D) to support construction of the first ten instruments and to establish the infrastructure to support later development and construction of additional instruments

  1. Instruments and accessories for neutron scattering research

    International Nuclear Information System (INIS)

    Ishii, Yoshinobu; Morii, Yukio

    2000-04-01

    This report describes neutron scattering instruments and accessories installed by four neutron scattering research groups at the ASRC (Advanced Science Research Center) of the JAERI and the recent topics of neutron scattering research using these instruments. The specifications of nine instruments (HRPD, BIX-I, TAS-1 and PNO in the reactor hall, RESA, BIX-II, TAS-2, LTAS and SANS-J in the guide hall of the JRR-3M) are summarized in this booklet. (author)

  2. Digital instrumentation for retrofit applications

    International Nuclear Information System (INIS)

    Dennis, U.E.

    1986-01-01

    There can be many reasons for applying retrofit designs to existing power plants. Whatever the reasons, care in planning and instrument design will be required in order to derive the full benefits afforded by today's technology. Specifically, the availability of microprocessors and their related integrated circuits make possible capabilities, accuracies, reliabilities, maintainability and user interfaces not achievable when original equipment was designed. Some of the motives for the replacement of current instrumentation are examined and the various benefits and pitfalls of applying present day microprocessor technology to new designs are discussed. From this, a set of design objectives can be formulated that can best take advantage of modern technology. General Electric's design solution, a family of instruments called NUMAC (Nuclear Measurement, Analysis and Control) is described, followed by descriptions of instruments currently in production and those contemplated for design in the near future

  3. PEP instrumentation and control system

    Energy Technology Data Exchange (ETDEWEB)

    Melen, R.

    1980-06-01

    This paper describes the operating characteristics of the primary components that form the PEP Instrumentation and Control System. Descriptions are provided for the computer control system, beam monitors, and other support systems.

  4. PEP instrumentation and control system

    International Nuclear Information System (INIS)

    Melen, R.

    1980-06-01

    This paper describes the operating characteristics of the primary components that form the PEP Instrumentation and Control System. Descriptions are provided for the computer control system, beam monitors, and other support systems

  5. A Computer-Based Instrument That Identifies Common Science Misconceptions

    Science.gov (United States)

    Larrabee, Timothy G.; Stein, Mary; Barman, Charles

    2006-01-01

    This article describes the rationale for and development of a computer-based instrument that helps identify commonly held science misconceptions. The instrument, known as the Science Beliefs Test, is a 47-item instrument that targets topics in chemistry, physics, biology, earth science, and astronomy. The use of an online data collection system…

  6. Ocean Bottom Seismograph Performance during the Cascadia Initiative

    Science.gov (United States)

    Aderhold, K.; Evers, B.

    2015-12-01

    The Ocean Bottom Seismograph Instrument Pool (OBSIP) provides instrumentation and operations support for the Cascadia Initiative community experiment. This experiment investigates geophysical processes across the Cascadia subduction zone through a combination of onshore and offshore seismic data. The recovery of Year 4 instruments in September 2015 marks the conclusion of a multi-year experiment that utilized 60 ocean-bottom seismographs (OBSs) specifically designed for the subduction zone boundary, including shallow/deep water deployments and active fisheries. The new instruments feature trawl-resistant enclosures designed by Lamont-Doherty Earth Observatory (LDEO) and Scripps Institution of Oceanography (SIO) for shallow deployment [water depth ≤ 500 m], as well as new deep-water instruments designed by Woods Hole Oceanographic Institute (WHOI). Existing OBSIP instruments were also deployed along the Blanco Transform Fault and on the Gorda Plate through complementary experiments. Stations include differential pressure gauges (DPG) and absolute pressure gauges (APG). All data collected from the Cascadia, Blanco, and Gorda deployments will be freely available through the Incorporated Research Institutions for Seismology (IRIS) Data Management Center (DMC). The Cascadia Initiative is the largest amphibious seismic experiment undertaken to date and demonstrates an effective structure for community experiments through collaborative efforts from the Cascadia Initiative Expedition Team (CIET), OBSIP (institutional instrument contributors [LDEO, SIO, WHOI] and Management Office [IRIS]), and the IRIS DMC. The successes and lessons from Cascadia are a vital resource for the development of a Subduction Zone Observatory (SZO). To guide future efforts, we investigate the quality of the Cascadia OBS data using basic metrics such as instrument recovery and more advanced metrics such as noise characteristics through power spectral density analysis. We also use this broad and

  7. Initial Psychometric Properties of a Brief Parent-Report Instrument for Assessing Tic Severity in Children with Chronic Tic Disorders

    Science.gov (United States)

    Chang, Susanna; Himle, Michael B.; Tucker, Benjamin T. P.; Woods, Douglas W.; Piacentini, John

    2009-01-01

    This article describes the development and initial psychometric properties of the Parent Tic Questionnaire (PTQ)--a new measure assessing the number, frequency, and intensity of motor and vocal tics in children and adolescents with Chronic Tic Disorder (CTD). Parents of 40 children with a CTD completed the PTQ as part of a larger assessment…

  8. Alberta Learning: Early Development Instrument Pilot Project Evaluation.

    Science.gov (United States)

    Meaney, Wanda; Harris-Lorenze, Elayne

    The Early Development Instrument (EDI) was designed by McMaster University to measure the outcomes of childrens early years as they influence their readiness to learn at school. The EDI was piloted in several Canadian cities in recent years through two national initiatives. Building on these initiatives, Alberta Learning piloted the EDI as a…

  9. RICE: A Reliable and Efficient Remote Instrumentation Collaboration Environment

    Directory of Open Access Journals (Sweden)

    Prasad Calyam

    2008-01-01

    Full Text Available Remote access of scientific instruments over the Internet (i.e., remote instrumentation demand high-resolution (2D and 3D video image transfers with simultaneous real-time mouse and keyboard controls. Consequently, user quality of experience (QoE is highly sensitive to network bottlenecks. Further, improper user control while reacting to impaired video caused due to network bottlenecks could result in physical damages to the expensive instrument equipment. Hence, it is vital to understand the interplay between (a user keyboard/mouse actions toward the instrument, and (b corresponding network reactions for transfer of instrument video images toward the user. In this paper, we first present an analytical model for characterizing user and network interplay during remote instrumentation sessions in terms of demand and supply interplay principles of traditional economics. Next, we describe the trends of the model parameters using subjective and objective measurements obtained from QoE experiments. Thereafter, we describe our Remote Instrumentation Collaboration Environment (RICE software that leverages our experiences from the user and network interplay studies, and has functionalities that facilitate reliable and efficient remote instrumentation such as (a network health awareness to detect network bottleneck periods, and (b collaboration tools for multiple participants to interact during research and training sessions.

  10. Counselor Competence, Performance Assessment, and Program Evaluation: Using Psychometric Instruments

    Science.gov (United States)

    Tate, Kevin A.; Bloom, Margaret L.; Tassara, Marcel H.; Caperton, William

    2014-01-01

    Psychometric instruments have been underutilized by counselor educators in performance assessment and program evaluation efforts. As such, we conducted a review of the literature that revealed 41 instruments fit for such efforts. We described and critiqued these instruments along four dimensions--"Target Domain," "Format,"…

  11. Nuclear reactor instrumentation at research reactor renewal

    International Nuclear Information System (INIS)

    Baers, B.; Pellionisz, P.

    1981-10-01

    The paper overviews the state-of-the-art of research reactor renewals. As a case study the instrumentation reconstruction of the Finnish 250 kW TRIGA reactor is described, with particular emphasis on the nuclear control instrumentation and equipment which has been developed and manufactured by the Central Research Institute for Physics, Budapest. Beside the presentation of the nuclear instrument family developed primarily for research reactor reconstructions, the quality assurance policy conducted during the manufacturing process is also discussed. (author)

  12. Instrumentation between science, state and industry

    CERN Document Server

    Shinn, Terry

    2001-01-01

    these. In this book, we appropriate their conception of research-technology, and ex­ tend it to many other phenomena which are less stable and less localized in time and space than the Zeeman/Cotton situation. In the following pages, we use the concept for instances where research activities are orientated primarily toward technologies which facilitate both the production of scientific knowledge and the production of other goods. In particular, we use the tenn for instances where instruments and meth­ ods· traverse numerous geographic and institutional boundaries; that is, fields dis­ tinctly different and distant from the instruments' and methods' initial focus. We suggest that instruments such as the ultra-centrifuge, and the trajectories of the men who devise such artefacts, diverge in an interesting way from other fonns of artefacts and careers in science, metrology and engineering with which students of science and technology are more familiar. The instrument systems developed by re­ search-technolo...

  13. Instrument calls and real-time code for laboratory automation

    International Nuclear Information System (INIS)

    Taber, L.; Ames, H.S.; Yamauchi, R.K.; Barton, G.W. Jr.

    1978-01-01

    These programs are the result of a joint Lawrence Livermore Laboratory and Environmental Protection Agency project to automate water quality laboratories. They form the interface between the analytical instruments and the BASIC language programs for data reduction and analysis. They operate on Data General NOVA 840's at Cincinnati and Chicago and on a Data General ECLIPSE C330 at Livermore. The operating system consists of unmodified RDOS, Data General's disk operating system, and Data General's multiuser BASIC modified to provide the instrument CALLs and other functions described. Instruments automated at various laboratories include Technicon AutoAnalyzers, atomic absorption spectrophotometers, total organic carbon analyzers, an emission spectrometer, an electronic balance, sample changers, and an optical spectrophotometer. Other instruments may be automated using these same CALLs, or new CALLs may be written as described

  14. Math Garden: A new educational and scientific instrument

    NARCIS (Netherlands)

    Straatemeier, M.

    2014-01-01

    This dissertation describes the research concerning the construction of a new educational and scientific instrument. This instrument, Math Garden, is a web application in which children can practice arithmetic by playing math games in which items are tailored to their ability level. At the same

  15. Apical instrumentation in endodontic therapy

    Directory of Open Access Journals (Sweden)

    Kurniasri Darliana

    2007-07-01

    Full Text Available Cleaning and shaping of the root canal as the foundation for successful endodontic therapy. Cleaning of the root canal as the removal of all the contents of the root canal systems before and during shaping. Mechanical cleaning as the most important part of the root canal therapy. Instrumentation of the apical region has long been considered to be an essential component in the cleaning and shaping process. The apical area as the critical zone for instrumentation. The apical portion of the root canal system can retain microorganisms that could potentially cause periradicular inflammation. The nickel-titanium rotary instrumentation system to facilitate the cleaning and shaping process. Larger instrumentation sizes not only allow proper irrigation but also significantly decrease remaining bacteria in the canal system. How the larger apical sizes preparation must be achieved to clinical success. This paper will describe the major factors impacting the selection of final apical size, the factors are the anatomy of the apical constriction, root canal diameter, apical instrumentation, and bacteria in dentin tubuli.

  16. Instrumental neutron activation analysis - a routine method

    International Nuclear Information System (INIS)

    Bruin, M. de.

    1983-01-01

    This thesis describes the way in which at IRI instrumental neutron activation analysis (INAA) has been developed into an automated system for routine analysis. The basis of this work are 20 publications describing the development of INAA since 1968. (Auth.)

  17. Design and implementation of a wireless instrument adapter

    DEFF Research Database (Denmark)

    Laino, Kaori V.; Saathoff, Thore; Savarimuthu, Thiusius R.

    2018-01-01

    The evaluation of new methods for control and manipulation in minimally invasive robotic surgery requires a realistic setup. To decouple the evaluation of methods from overall clinical systems, we propose an instrument adapter for the S line EndoWrist\\c{opyright} instruments of the da Vinci...... surgical system. The adapter is small and lightweight and can be mounted to any robot to mimic motion. We describe its design and implementation, as well as a setup to calibrate instruments to study precise motion control. Our results indicate that each instrument requires individual calibration...

  18. Temperature documentation - instrument for quality assurance; Temperaturdokumentation - Instrument der Qualitaetssicherung

    Energy Technology Data Exchange (ETDEWEB)

    Hegglin, A [Wurm AG, Winterthur (Switzerland)

    2000-10-01

    Important inspection points of a HACCP concept are the temperatures. On the basis of the demands for a systematic temperature documentation, the application of control systems and instruments is described by several examples. (orig.) [German] Wichtige Kontrollpunkte eines HACCP-Konzepts sind die Temperaturen. Ausgehend von den Anforderungen, die an eine systematische Temperaturedokumentation gestellt werden, wird der Einsatz geeigneter Regel- und Ueberwachungsgeraete an mehreren Beispielen erlaeutert. (orig.)

  19. Breastfeeding Self-efficacy: A Critical Review of Available Instruments

    Science.gov (United States)

    Tuthill, Emily L.; McGrath, Jacqueline M.; Graber, Melanie; Cusson, Regina M.; Young, Sera L.

    2016-01-01

    Increasing breastfeeding rates in the United States is a national priority. Yet, initiation and duration of breastfeeding remains below national targets. Breastfeeding self-efficacy has been shown to be a strong predictor of both breastfeeding initiation and duration and is therefore an important characteristic to be able to measure. However, there is currently a myriad of instruments for measuring breastfeeding self-efficacy, which makes selection of an appropriate instrument difficult. Thus, our aim was to identify, compare, and critically review available breastfeeding self-efficacy instruments. In a systematic review, 6 breastfeeding self-efficacy instruments were identified. The instruments’ purposes, theoretical framework, final scale development, and application in 5 most recent settings were analyzed. The 6 breastfeeding self-efficacy instruments apply a number of theoretical and conceptual frameworks in their development, with Bandura’s social cognitive theory being most common. Content, construct, and predictive validity were strong for most scales. Some, but not all, have been successfully adapted to novel settings. In sum, there are several measurements of breastfeeding self-efficacy that can and should be employed to better understand reasons for suboptimal breastfeeding rates and the effects of interventions on breastfeeding self-efficacy. Instrument selection should be based on domains of primary interest, time available, peripartum timing, and assessment of previous adaptations. Failure to apply appropriate measures in research may garner results that are inconclusive, inaccurate, or nonrepresentative of true study effects. PMID:26319113

  20. Radiation measuring instrument

    International Nuclear Information System (INIS)

    Genrich, V.

    1985-01-01

    A highly sensitive and compactly structured radiation measuring instrument for detecting ionizing radiation, in particular for measuring dose rates and contamination. The laminar structure of the associated counter tube, using only a few, simple plastic parts and a highly elastic counter wire, makes it possible to use the simplest manufacturing techniques. The service life of the counter tube construction, which is completely and permanently sealed and filled with gas, is expected to be more than 12 years. The described counter tube can be adapted in optimal fashion to the available space in a pocket instrument if it is used in combination with a specialized high-voltage generator which is low in interference voltage and with a pulse evaluation circuit having a means of compensating for interference voltage

  1. Development of material measures for performance verifying surface topography measuring instruments

    International Nuclear Information System (INIS)

    Leach, Richard; Giusca, Claudiu; Rickens, Kai; Riemer, Oltmann; Rubert, Paul

    2014-01-01

    The development of two irregular-geometry material measures for performance verifying surface topography measuring instruments is described. The material measures are designed to be used to performance verify tactile and optical areal surface topography measuring instruments. The manufacture of the material measures using diamond turning followed by nickel electroforming is described in detail. Measurement results are then obtained using a traceable stylus instrument and a commercial coherence scanning interferometer, and the results are shown to agree to within the measurement uncertainties. The material measures are now commercially available as part of a suite of material measures aimed at the calibration and performance verification of areal surface topography measuring instruments

  2. A new aberration-corrected, energy-filtered LEEM/PEEM instrument. I. Principles and design

    International Nuclear Information System (INIS)

    Tromp, R.M.; Hannon, J.B.; Ellis, A.W.; Wan, W.; Berghaus, A.; Schaff, O.

    2010-01-01

    We describe a new design for an aberration-corrected low energy electron microscope (LEEM) and photo electron emission microscope (PEEM), equipped with an in-line electron energy filter. The chromatic and spherical aberrations of the objective lens are corrected with an electrostatic electron mirror that provides independent control over the chromatic and spherical aberration coefficients C c and C 3 , as well as the mirror focal length, to match and correct the aberrations of the objective lens. For LEEM (PEEM) the theoretical resolution is calculated to be ∼1.5 nm (∼4 nm). Unlike previous designs, this instrument makes use of two magnetic prism arrays to guide the electron beam from the sample to the electron mirror, removing chromatic dispersion in front of the mirror by symmetry. The aberration correction optics was retrofitted to an uncorrected instrument with a base resolution of 4.1 nm in LEEM. Initial results in LEEM show an improvement in resolution to ∼2 nm.

  3. Instrumentation maintenance

    International Nuclear Information System (INIS)

    Mack, D.A.

    1976-09-01

    It is essential to any research activity that accurate and efficient measurements be made for the experimental parameters under consideration for each individual experiment or test. Satisfactory measurements in turn depend upon having the necessary instruments and the capability of ensuring that they are performing within their intended specifications. This latter requirement can only be achieved by providing an adequate maintenance facility, staffed with personnel competent to understand the problems associated with instrument adjustment and repair. The Instrument Repair Shop at the Lawrence Berkeley Laboratory is designed to achieve this end. The organization, staffing and operation of this system is discussed. Maintenance policy should be based on studies of (1) preventive vs. catastrophic maintenance, (2) records indicating when equipment should be replaced rather than repaired and (3) priorities established to indicate the order in which equipment should be repaired. Upon establishing a workable maintenance policy, the staff should be instructed so that they may provide appropriate scheduled preventive maintenance, calibration and corrective procedures, and emergency repairs. The education, training and experience of the maintenance staff is discussed along with the organization for an efficient operation. The layout of the various repair shops is described in the light of laboratory space and financial constraints

  4. Borehole instrument for scintillation gamma spectrometer

    International Nuclear Information System (INIS)

    Sinitsyn, A.Ya.; Gabitov, R.M.

    1979-01-01

    Described are a schematic diagram and main specifications of a borehole instrument with autostabilization of energy scale measure by gamma bench-mark of 137 Cs, intended for the application in a logging gamma spectrometer to determine separately the concentrations of nature radioactive elements. The instrument may be connected to the KOBDFM-2 cable of 600 m length. It contains a scintillation counter for gamma quanta consisting of 30x70 mm NaI(Tl) crystal and a FEU-85 photoamplifier, an input conforming stage, a diagram of threshold pulse formation and regulating high-voltage generator. The borehole instrument has been proved under laboratory and field conditions at 10-40 deg C

  5. IAEA programme on maintenance of nuclear instruments

    International Nuclear Information System (INIS)

    Vuister, P.H.

    1986-01-01

    The Medical Applications Section in the Division of Life Sciences of the International Atomic Energy Agency has been engaged since 1975 in activities aimed at the more effective use of nuclear instruments. Activities and achievements are described concerning the conditioning of laboratories, preventive maintenance and repair of instruments, the management thereof, space parts and the promotion of local training in these subjects. (author)

  6. Validity evidence of non-technical skills assessment instruments in simulated anaesthesia crisis management.

    Science.gov (United States)

    Jirativanont, T; Raksamani, K; Aroonpruksakul, N; Apidechakul, P; Suraseranivongse, S

    2017-07-01

    We sought to evaluate the validity of two non-technical skills evaluation instruments, the Anaesthetists' Non-Technical Skills (ANTS) behavioural marker system and the Ottawa Global Rating Scale (GRS), to apply them to anaesthesia training. The content validity, response process, internal structure, relations with other variables and consequences were described for validity evidence. Simulated crisis management sessions were initiated during which two trained raters evaluated the performance of postgraduate first-, second- and third-year (PGY-1, PGY-2 and PGY-3) anaesthesia residents. The study included 70 participants, composed of 24 PGY-1, 24 PGY-2 and 22 PGY-3 residents. Both instruments differentiated the non-technical skills of PGY-1 from PGY-3 residents ( P skills were 0.86, 0.83, 0.84, 0.87, 0.80 and 0.86, respectively. The Cronbach's alpha for internal consistency of the ANTS instrument was 0.93, and was 0.96 for the Ottawa GRS. There was a high correlation between the ANTS and Ottawa GRS. The raters reported the ease of use of the Ottawa GRS compared to the ANTS. We found sufficient evidence of validity in the ANTS instrument and the Ottawa GRS for the evaluation of non-technical skills in a simulated anaesthesia setting, but the Ottawa GRS was more practical and had higher reliability.

  7. Sulfur Dioxide Analyzer Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Springston, Stephen R. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-05-01

    The Sulfur Dioxide Analyzer measures sulfur dioxide based on absorbance of UV light at one wavelength by SO2 molecules which then decay to a lower energy state by emitting UV light at a longer wavelength. Specifically, SO2 + hυ1 →SO2 *→SO2 + hυ2 The emitted light is proportional to the concentration of SO2 in the optical cell. External communication with the analyzer is available through an Ethernet port configured through the instrument network of the AOS systems. The Model 43i-TLE is part of the i-series of Thermo Scientific instruments. The i-series instruments are designed to interface with external computers through the proprietary Thermo Scientific iPort Software. However, this software is somewhat cumbersome and inflexible. Brookhaven National Laboratory (BNL) has written an interface program in National Instruments LabView that both controls the Model 43i-TLE Analyzer AND queries the unit for all measurement and housekeeping data. The LabView vi (the software program written by BNL) ingests all raw data from the instrument and outputs raw data files in a uniform data format similar to other instruments in the AOS and described more fully in Section 6.0 below.

  8. Instrument for measuring metal-thermoelectric semiconductor contact resistence

    International Nuclear Information System (INIS)

    Lanxner, M.; Nechmadi, M.; Meiri, B.; Schildkraut, I.

    1979-02-01

    An instrument for measuring electrical, metal-thermoelectric semiconductor contact resistance is described. The expected errors of measurement are indicated. The operation of the instrument which is based on potential traversing perpendicularly to the contact plane is illustrated for the case of contacts of palladium and bismuth telluride-based thermoelectric material

  9. Development of smart nuclear instrumentation for reactors

    International Nuclear Information System (INIS)

    Chaganty, S.P.; Das, D.; Bhatnagar, P.V.; Das, A.; Sreedharan, Preetha; Kataria, S.K.

    2001-01-01

    Variety of nuclear instruments are required for different applications in reactors such as reactor start-up, reactor protection and regulating system, area monitoring, failed fuel detection, stack monitoring etc. Attempts are made to develop a standardized microcomputer based hardware for configuring different types of instruments. PC architecture is chosen due to easy availability of components/boards and software. These instruments have dual redundant Network Interface Cards for connecting to a Primary Radiation Data LAN which in turn can be connected to Plant Information Bus through Gateways. These SMART instruments can be tested/calibrated through specific commands from remote computers connected over the LAN. This paper describes the various issues involved and the design details. (author)

  10. Trends in instrumentation for environmental radiation measurements at Los Alamos Scientific Laboratory

    International Nuclear Information System (INIS)

    Hiebert, R.D.; Wolf, M.A.

    1980-01-01

    Recent instruments developed to fulfill radiation monitoring needs at Los Alamos Scientific Laboratory are described. Laboratory instruments that measure tritium gas effluents alone, or in the presence of activated air from D-T fusion reactors are discussed. Fully portable systems for gamma, x-ray, and alpha analyses in the field are described. Also included are descriptions of survey instruments that measure low levels of transuranic contaminants and that measure pulsed-neutron dose rates

  11. Evaluating the effectiveness of impact assessment instruments

    DEFF Research Database (Denmark)

    Cashmore, Matthew; Richardson, Tim; Hilding-Ryedvik, Tuija

    2010-01-01

    to sharpen effectiveness evaluation theory for impact assessment instruments this article critically examines the neglected issue of their political constitution. Analytical examples are used to concretely explore the nature and significance of the politicisation of impact assessment. It is argued......The central role of impact assessment instruments globally in policy integration initiatives has been cemented in recent years. Associated with this trend, but also reflecting political emphasis on greater accountability in certain policy sectors and a renewed focus on economic competitiveness...... that raising awareness about the political character of impact assessment instruments, in itself, is a vital step in advancing effectiveness evaluation theory. Broader theoretical lessons on the framing of evaluation research are also drawn from the political analysis. We conclude that, at least within...

  12. Requirements for a quality measurement instrument for semantic standards

    NARCIS (Netherlands)

    Folmer, E.J.A.; Krukkert, D.; Oude Luttighuis, P.; Hillegersberg van, J. van

    2010-01-01

    This study describes requirements for an instrument to measure the quality of semantic standards. A situational requirements engineering method was used, resulting in a goal-tree in which requirements are structured. This structure shows requirements related to the input of the instrument; stating

  13. Instrument translation and initial psychometric evaluation of the Danish Body Image Quality of Life Inventory

    DEFF Research Database (Denmark)

    Rasmussen, Trine Bernholdt; Berg, Selina Kikkenborg; Dixon, Jane

    2016-01-01

    . The purpose of the study was thus to translate and validate a Danish version of the Body Image Quality of Life Inventory (BIQLI), in order to obtain a valid instrument applicable for healthcare research. METHODS: The study consisted of two phases: (i) instrument adaptation, including forward and back...... to be semantically sound, yet concerns about face validity did arise through cognitive interviews. Danish college students (n = 189, 65 men, Mage = 21.1 years) participated in the piloting of the BIQLI-DA. Convergent construct validity was demonstrated through associations to related constructs. Exploratory factor...

  14. Instrumental systematics and weak gravitational lensing

    International Nuclear Information System (INIS)

    Mandelbaum, R.

    2015-01-01

    We present a pedagogical review of the weak gravitational lensing measurement process and its connection to major scientific questions such as dark matter and dark energy. Then we describe common ways of parametrizing systematic errors and understanding how they affect weak lensing measurements. Finally, we discuss several instrumental systematics and how they fit into this context, and conclude with some future perspective on how progress can be made in understanding the impact of instrumental systematics on weak lensing measurements

  15. Instrument for track linear element recognition

    International Nuclear Information System (INIS)

    Krupnov, V.E.; Fedotov, O.P.

    1977-01-01

    Described is the construction of instrument for recognizing linear elements of tracks. For designing this instrument use has been made of the algorithm for conversion of the point data into a set of linear elements. The flowsheet of the instrument shows its major units such as data converter, data representation register unit, local computers, interface with the central computer. The data representation register unit comprises sixteen registers and is capable of presenting data from sixteen lines when raster scanning of a picture taken from a track chamber. The maximum capacity of the code of the coordinate of a point recorded on a picture is up to 16 digits. The time of the inner operating cycle of the instrument is 1.3 μs. The average time required for processing data containing sixteen scanning lines is 250 μs

  16. A Musical instrument in MEMS

    NARCIS (Netherlands)

    Engelen, Johannes Bernardus Charles; de Boer, Hans L.; de Boer, H.; Beekman, J.G.; Been, A.J.; Folkertsma, Gerrit Adriaan; Folkertsma, G.A.; Fortgens, L.; de Graaf, D.; Vocke, S.; Woldering, L.A.; Abelmann, Leon; Elwenspoek, Michael Curt

    In this work we describe a MEMS instrument that resonates at audible frequencies, and with which music can be made. The sounds are generated by mechanical resonators and capacitive displacement sensors. Damping by air scales unfavourably for generating audible frequencies with small devices.

  17. Onboard calibration and monitoring for the SWIFT instrument

    International Nuclear Information System (INIS)

    Rahnama, P; McDade, I; Shepherd, G; Gault, W

    2012-01-01

    The SWIFT (Stratospheric Wind Interferometer for Transport studies) instrument is a proposed space-based field-widened Doppler Michelson interferometer designed to measure stratospheric winds and ozone densities using a passive optical technique called Doppler Michelson imaging interferometry. The onboard calibration and monitoring procedures for the SWIFT instrument are described in this paper. Sample results of the simulations of onboard calibration measurements are presented and discussed. This paper also discusses the results of the derivation of the calibrations and monitoring requirements for the SWIFT instrument. SWIFT's measurement technique and viewing geometry are briefly described. The reference phase calibration and filter monitoring for the SWIFT instrument are two of the main critical design issues. In this paper it is shown that in order to meet SWIFT's science requirements, Michelson interferometer optical path difference monitoring corresponding to a phase calibration accuracy of ∼10 −3 radians, filter passband monitoring corresponding to phase accuracy of ∼5 × 10 −3 radians and a thermal stability of 10 −3 K s −1 are required. (paper)

  18. An Intelligent Hand-Held Microsurgical Instrument for Improved Accuracy

    National Research Council Canada - National Science Library

    Ang, Wei

    2001-01-01

    This paper presents the development and initial experimental results of the first prototype of Micron, an active hand-held instrument to sense and compensate physiological tremor and other unwanted...

  19. The Pavlovian analysis of instrumental conditioning.

    Science.gov (United States)

    Gormezano, I; Tait, R W

    1976-01-01

    An account was given of the development within the Russian literature of a uniprocess formulation of classical and instrumental conditioning, known as the bidirectional conditioning hypothesis. The hypothesis purports to offer a single set of Pavlovian principles to account for both paradigms, based upon a neural model which assumes that bidirectional (forward and backward) connections are formed in both calssical and instrumental conditioning situations. In instrumental conditioning, the bidirectional connections are hypothesized to be simply more complex than those in classical conditioning, and any differences in empirical functions are presumed to lie not in difference in mechanism, but in the strength of the forward and backward connections. Although bidirectional connections are assumed to develop in instrumental conditioning, the experimental investigation of the bidirectional conditioning hypothesis has been essentially restricted to the classical conditioning operations of pairing two CSs (sensory preconditioning training), a US followed by a CS (backward conditioning training) and two USs. However, the paradigm involving the pairing of two USs, because of theoretical and analytical considerations, is the one most commonly employed by Russian investigators. The results of an initial experiment involving the pairing of two USs, and reference to the results of a more extensive investigation, leads us to tentatively question the validity of the bidirectional conditioning account of instrumental conditioning.

  20. [Development of new magnetic bead separation and purification instrument].

    Science.gov (United States)

    Xu, Yingyuan; Chen, Yi

    2014-05-01

    The article describes the development of new magnetic bead separation and purification instrument. The main application of the instrument is to capture tubercle bacillus from sputum. It is a pretreatment instrument and provides a new platform to help doctors to diagnose bacillary phthisis. Not only could it be used for tubercle bacillus capturing, but also for gene, protein and cell separating and purification. Because the controller of the instrument is 16-bit single chip microcomputer, the cost could be greatly reduced and it will be widely used in China.

  1. Innovative instrumentation for VVERs based in non-invasive techniques

    International Nuclear Information System (INIS)

    Jeanneau, H.; Favennec, J.M.; Tournu, E.; Germain, J.L.

    2000-01-01

    Nuclear power plants such as VVERs can greatly benefit from innovative instrumentation to improve plant safety and efficiency. In recent years innovative instrumentation has been developed for PWRs with the aim of providing additional measurements of physical parameters on the primary and secondary circuits: the addition of new instrumentation is made possible by using non-invasive techniques such as ultrasonics and radiation detection. These innovations can be adapted for upgrading VVERs presently in operation and also in future VVERs. The following innovative instrumentation for the control, monitoring or testing at VVERs is described: 1. instrumentation for more accurate primary side direct measurements (for a better monitoring of the primary circuit); 2. instrumentation to monitor radioactivity leaks (for a safer plant); 3. instrumentation-related systems to improve the plant efficiency (for a cheaper kWh)

  2. Evaluation of behaviors of earth and rockfill dams during construction and initial impounding using instrumentation data and numerical modeling

    Directory of Open Access Journals (Sweden)

    Mohammad Rashidi

    2017-08-01

    Full Text Available In this study, the behavior of Gavoshan dam was evaluated during construction and the first impounding. A two-dimensional (2D numerical analysis was conducted based on a finite difference method on the largest cross-section of the dam using the results of instrument measurements and back analysis. These evaluations will be completed in the case that back analysis is carried out in order to control the degree of the accuracy and the level of confidence of the measured behavior since each of the measurements could be controlled by comparing it to the result obtained from the numerical model. Following that, by comparing the results of the numerical analysis with the measured values, it is indicated that there is a proper consistency between these two values. Moreover, it was observed that the dam performance was suitable regarding the induced pore water pressure, the pore water pressure ratio ru, settlement, induced stresses, arching degree, and hydraulic fracturing probability during the construction and initial impounding periods. The results demonstrated that the maximum settlement of the core was 238 cm at the end of construction. In the following 6 years after construction (initial impounding and exploitation period, the accumulative settlement of the dam was 270 cm. It is clear that 88% of the total settlement of the dam took place during dam construction. The reason is that the clay core was smashed in the wet side, i.e. the optimum moisture content. Whereas the average curving ratio was 0.64 during dam construction; at the end of the initial impounding, the maximum amount of curving ratio in the upstream was 0.81, and the minimum (critical amount in the downstream was 0.52. It was also concluded that this dam is safe in comparison with the behaviors of other similar dams in the world.

  3. Avoidance-based human Pavlovian-to-instrumental transfer

    Science.gov (United States)

    Lewis, Andrea H.; Niznikiewicz, Michael A.; Delamater, Andrew R.; Delgado, Mauricio R.

    2013-01-01

    The Pavlovian-to-instrumental transfer (PIT) paradigm probes the influence of Pavlovian cues over instrumentally learned behavior. The paradigm has been used extensively to probe basic cognitive and motivational processes in studies of animal learning but, more recently, PIT and its underlying neural basis have been extended to investigations in humans. These initial neuroimaging studies of PIT have focused on the influence of appetitively conditioned stimuli on instrumental responses maintained by positive reinforcement, and highlight the involvement of the striatum. In the current study, we sought to understand the neural correlates of PIT in an aversive Pavlovian learning situation when instrumental responding was maintained through negative reinforcement. Participants exhibited specific PIT, wherein selective increases in instrumental responding to conditioned stimuli occurred when the stimulus signaled a specific aversive outcome whose omission negatively reinforced the instrumental response. Additionally, a general PIT effect was observed such that when a stimulus was associated with a different aversive outcome than was used to negatively reinforce instrumental behavior, the presence of that stimulus caused a non-selective increase in overall instrumental responding. Both specific and general PIT behavioral effects correlated with increased activation in corticostriatal circuitry, particularly in the striatum, a region involved in cognitive and motivational processes. These results suggest that avoidance-based PIT utilizes a similar neural mechanism to that seen with PIT in an appetitive context, which has implications for understanding mechanisms of drug-seeking behavior during addiction and relapse. PMID:24118624

  4. Evaluation of Instrumentation and Dynamic Thermal Ratings for Overhead Lines

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, A. [New York Power Authority, White Plains, NY (United States)

    2013-01-31

    In 2010, a project was initiated through a partnership between the Department of Energy (DOE) and the New York Power Authority (NYPA) to evaluate EPRI's rating technology and instrumentation that can be used to monitor the thermal states of transmission lines and provide the required real-time data for real-time rating calculations. The project included the installation and maintenance of various instruments at three 230 kV line sites in northern New York. The instruments were monitored, and data collection and rating calculations were performed for about a three year period.

  5. Feedback control of acoustic musical instruments: collocated control using physical analogs.

    Science.gov (United States)

    Berdahl, Edgar; Smith, Julius O; Niemeyer, Günter

    2012-01-01

    Traditionally, the average professional musician has owned numerous acoustic musical instruments, many of them having distinctive acoustic qualities. However, a modern musician could prefer to have a single musical instrument whose acoustics are programmable by feedback control, where acoustic variables are estimated from sensor measurements in real time and then fed back in order to influence the controlled variables. In this paper, theory is presented that describes stable feedback control of an acoustic musical instrument. The presentation should be accessible to members of the musical acoustics community who may have limited or no experience with feedback control. First, the only control strategy guaranteed to be stable subject to any musical instrument mobility is described: the sensors and actuators must be collocated, and the controller must emulate a physical analog system. Next, the most fundamental feedback controllers and the corresponding physical analog systems are presented. The effects that these controllers have on acoustic musical instruments are described. Finally, practical design challenges are discussed. A proof explains why changing the resonance frequency of a musical resonance requires much more control power than changing the decay time of the resonance. © 2012 Acoustical Society of America.

  6. Backscattering at a pulsed neutron source, the MUSICAL instrument

    International Nuclear Information System (INIS)

    Alefeld, B.

    1995-01-01

    In the first part the principles of the neutron backscattering method are described and some simple considerations about the energy resolution and the intensity are presented. A prototype of a backscattering instrument, the first Juelich instrument, is explained in some detail and a representative measurement is shown which was performed on the backscattering instrument IN10 at the ILL in Grenoble. In the second part a backscattering instrument designed for a pulsed neutron source is proposed. It is shown that a rather simple modification, which consists in the replacement of the Doppler drive of the conventional backscattering instrument by a multi silicon monochromator crystal (MUSICAL) leads to a very effective instrument, benefitting from the peak flux of the pulsed source. ((orig.))

  7. Nuclear electronic instrument systems using the Harwell 6000 series

    International Nuclear Information System (INIS)

    Seymour, F.D.; Snelling, G.F.; Hawthorn, I.

    1980-01-01

    This report describes some of the more recent equipment designed by the Systems Instrumentation Unit (AERE, Harwell), in the Harwell 6000 modular format. The units include: Laboratory Instruments (alpha monitors, beta-gamma detectors, spectrometers, automatic sample changer systems, automated counting laboratory systems, low power systems). Environmental Monitors (nuclear plant monitor, air monitor, sea bed monitor). Process Instruments (plutonium waste control, x-ray fluorescence monitor, process monitor, beam current monitor, effluent monitors). (U.K.)

  8. Music@Home: A novel instrument to assess the home musical environment in the early years.

    Science.gov (United States)

    Politimou, Nina; Stewart, Lauren; Müllensiefen, Daniel; Franco, Fabia

    2018-01-01

    The majority of children under the age of 5 appear to show spontaneous enjoyment of singing, being exposed to music and interacting with musical instruments, but whether variations in engaging in such activities in the home could contribute to developmental outcomes is still largely unknown. Critically, researchers lack a comprehensive instrument with good psychometric properties to assess the home musical environment from infancy to the preschool years. To address this gap, this paper presents two studies that describe the development and validation of the Music@Home questionnaire, which comprises two versions: Infant and Preschool. In Study 1, an initial pool of items was generated and administered to a wide audience of parents (n = 287 for the Infant, n = 347 for the Preschool version). Exploratory factor analysis was used to identify different dimensions comprising the home musical environment of both infants and pre-schoolers, and to reduce the initial pool of items to a smaller number of meaningful items. In Study 2, convergent and divergent validity and internal and test-retest reliability of the new instrument were established, using data from a different sample of participants (n = 213 for the Infant, n = 213 for the Preschool version). The second study also investigated associations between the Music@Home and musical characteristics of the parents, such as their musical education and personal engagement with music. Overall, the Music@Home constitutes a novel, valid and reliable instrument that allows for the systematic assessment of distinct aspects of the home musical environment in families with children under the age of 5. Furthermore, the Infant and Preschool versions of the Music@Home present differential associations with musical characteristics of the parents opening a new area of inquiry into how musical exposure and interaction in the home may vary across different developmental stages.

  9. Music@Home: A novel instrument to assess the home musical environment in the early years

    Science.gov (United States)

    Stewart, Lauren; Müllensiefen, Daniel; Franco, Fabia

    2018-01-01

    The majority of children under the age of 5 appear to show spontaneous enjoyment of singing, being exposed to music and interacting with musical instruments, but whether variations in engaging in such activities in the home could contribute to developmental outcomes is still largely unknown. Critically, researchers lack a comprehensive instrument with good psychometric properties to assess the home musical environment from infancy to the preschool years. To address this gap, this paper presents two studies that describe the development and validation of the Music@Home questionnaire, which comprises two versions: Infant and Preschool. In Study 1, an initial pool of items was generated and administered to a wide audience of parents (n = 287 for the Infant, n = 347 for the Preschool version). Exploratory factor analysis was used to identify different dimensions comprising the home musical environment of both infants and pre-schoolers, and to reduce the initial pool of items to a smaller number of meaningful items. In Study 2, convergent and divergent validity and internal and test-retest reliability of the new instrument were established, using data from a different sample of participants (n = 213 for the Infant, n = 213 for the Preschool version). The second study also investigated associations between the Music@Home and musical characteristics of the parents, such as their musical education and personal engagement with music. Overall, the Music@Home constitutes a novel, valid and reliable instrument that allows for the systematic assessment of distinct aspects of the home musical environment in families with children under the age of 5. Furthermore, the Infant and Preschool versions of the Music@Home present differential associations with musical characteristics of the parents opening a new area of inquiry into how musical exposure and interaction in the home may vary across different developmental stages. PMID:29641607

  10. Development of instrument for assessing students’ critical and creative thinking ability

    Science.gov (United States)

    Herpiana, R.; Rosidin, U.

    2018-01-01

    The purpose of this study was to develop instruments to measure critical thinking ability and creative students in the topics of physics simple harmonic motion. The research method used was research development with application of procedures including research and data collection, planning, and initial product development. The participants of the study were thirty-four tenth grade students and five physics teachers of physics who were selected randomly from schools in the province of Lampung. The data collected by using test and analyzed in quantitative descriptive. Initial data showed that students’ critical and creative thinking ability were still low and instruments to assess students’ critical thinking skills and creative students was not yet available. Most of assessment conducted focused on memorization. Thus, the researchers developed a draft of instrument in the form of the test description based on criteria that encouraged students’ activity in understanding the concepts, strategies and decision/solution in dealing with problems. The development of the instrument was conducted considering real-world phenomena in the form of pictures and stories, description of the situation, and verbal presentation.

  11. Flight Test Guide (Part 61 Revised): Instrument Pilot: Helicopter.

    Science.gov (United States)

    Federal Aviation Administration (DOT), Washington, DC. Flight Standards Service.

    The guide provides an outline of the skills required to pass the flight test for an Instrument Pilot Helicopter Rating under Part 61 (revised) of Federal Aviation Regulations. General procedures for flight tests are described and the following pilot operations outlined: maneuvering by reference to instruments, IFR navigation, instrument…

  12. Year 2000 experience with safeguards instruments

    International Nuclear Information System (INIS)

    Coffing, J.

    1999-01-01

    Presentation covers the following items concerning the experiences with safeguards instruments related to Y2K issues: initial Y2K evaluation process; improvement of Y2K testing procedure, policy of the Aquila Technologies Group, Inc. The results concerning Y2K evaluation are presented as designed in the manufacturing process in order to assure success

  13. Quality assurance of radiation protection monitoring instruments in India

    International Nuclear Information System (INIS)

    Tripathi, S.M.; Daniel, Liji; Rao, Suresh; Sharma, D.N.

    2008-01-01

    Bhabha Atomic Research Centre (BARC) is the National Metrology Institute (NMI) for developing, maintaining and disseminating standards for ionizing radiation in India. Radiation Safety Systems Division (RSSD) of BARC has the requisite infrastructure in the form of experts, trained manpower, laboratories, equipment and facilities for providing calibration services to users and ascertaining traceability to international standards. It periodically participates in various international inter-comparisons. RSSD maintains reference radiation fields that are required for calibrating Radiation Protection Monitoring Instruments that form the backbone of the radiation monitoring programme for harnessing the benefits of nuclear energy and ionizing radiations. These instruments are type-tested and periodically calibrated at standard reference radiation fields to ensure their healthy working condition and fitness for their intended use. This paper describes the details of the standardization procedures adopted for reference radiation fields and infrastructure established and maintained at RSSD, BARC in accordance with the recommendations of ISO-4037. The paper describes the various tests that are carried out for radiation protection monitoring instrument to study the variation of the calibration factor with influencing quantities like linearity of response, energy response, angular dependence and overload characteristics. The results of these tests for typical instruments are also discussed. The present work also describes various types of indigenously developed radiation protection monitoring instruments and their performance characteristics. Adaptability of these instruments for the implementation of operational quantities are discussed briefly. It also dwells on the IAEA Quality Audit for radiation protection level calibrations, which RSSD has been participating since 2001. Our results of the quality audit are well within the acceptance limit (±7%) set by IAEA for the

  14. Understanding the interplay of cancer patients' instrumental concerns and emotions.

    Science.gov (United States)

    Brandes, Kim; van der Goot, Margot J; Smit, Edith G; van Weert, Julia C M; Linn, Annemiek J

    2017-05-01

    1) to assess patients' descriptions of concerns, and 2) to inform a conceptual framework in which the impact of the nature of concerns on doctor-patient communication is specified. Six focus groups were conducted with 39 cancer patients and survivors. In these focus groups participants were asked to describe their concerns during and after their illness. Concerns were described as instrumental concerns (e.g., receiving insufficient information) and emotions (e.g., sadness). Patients frequently explained their concerns as an interplay of instrumental concerns and emotions. Examples of the interplay were "receiving incorrect information" and "frustration", and "difficulties with searching, finding and judging of information" and "fear". Instrumental concerns need to be taken into account in the operationalization of concerns in research. Based on the interplay, the conceptual framework suggests that patients can express instrumental concerns as emotions and emotions as instrumental concerns. Consequently, providers can respond with instrumental and emotional communication when patients express an interplay of concerns. The results of this study can be used to support providers in recognizing concerns that are expressed by patients in consultations. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Portable digital lock-in instrument to determine chemical constituents with single-color absorption measurements for Global Health Initiatives

    Science.gov (United States)

    Vacas-Jacques, Paulino; Linnes, Jacqueline; Young, Anna; Gerrard, Victoria; Gomez-Marquez, Jose

    2014-03-01

    Innovations in international health require the use of state-of-the-art technology to enable clinical chemistry for diagnostics of bodily fluids. We propose the implementation of a portable and affordable lock-in amplifier-based instrument that employs digital technology to perform biochemical diagnostics on blood, urine, and other fluids. The digital instrument is composed of light source and optoelectronic sensor, lock-in detection electronics, microcontroller unit, and user interface components working with either power supply or batteries. The instrument performs lock-in detection provided that three conditions are met. First, the optoelectronic signal of interest needs be encoded in the envelope of an amplitude-modulated waveform. Second, the reference signal required in the demodulation channel has to be frequency and phase locked with respect to the optoelectronic carrier signal. Third, the reference signal should be conditioned appropriately. We present three approaches to condition the signal appropriately: high-pass filtering the reference signal, precise offset tuning the reference level by low-pass filtering, and by using a voltage divider network. We assess the performance of the lock-in instrument by comparing it to a benchmark device and by determining protein concentration with single-color absorption measurements. We validate the concentration values obtained with the proposed instrument using chemical concentration measurements. Finally, we demonstrate that accurate retrieval of phase information can be achieved by using the same instrument.

  16. Portable digital lock-in instrument to determine chemical constituents with single-color absorption measurements for Global Health Initiatives

    Energy Technology Data Exchange (ETDEWEB)

    Vacas-Jacques, Paulino [Little Devices Group, SUTD-MIT International Design Center, Cambridge, Massachusetts 02139 (United States); Wellman Center for Photomedicine and Harvard Medical School, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Linnes, Jacqueline [Little Devices Group, SUTD-MIT International Design Center, Cambridge, Massachusetts 02139 (United States); Biomedical Engineering Department, Boston University, Boston, Massachusetts 02215 (United States); Young, Anna; Gomez-Marquez, Jose [Little Devices Group, SUTD-MIT International Design Center, Cambridge, Massachusetts 02139 (United States); Gerrard, Victoria [Little Devices Group, SUTD-MIT International Design Center, Cambridge, Massachusetts 02139 (United States); Opportunity Lab, Singapore University for Technology and Design, Singapore 138682 (Singapore)

    2014-03-15

    Innovations in international health require the use of state-of-the-art technology to enable clinical chemistry for diagnostics of bodily fluids. We propose the implementation of a portable and affordable lock-in amplifier-based instrument that employs digital technology to perform biochemical diagnostics on blood, urine, and other fluids. The digital instrument is composed of light source and optoelectronic sensor, lock-in detection electronics, microcontroller unit, and user interface components working with either power supply or batteries. The instrument performs lock-in detection provided that three conditions are met. First, the optoelectronic signal of interest needs be encoded in the envelope of an amplitude-modulated waveform. Second, the reference signal required in the demodulation channel has to be frequency and phase locked with respect to the optoelectronic carrier signal. Third, the reference signal should be conditioned appropriately. We present three approaches to condition the signal appropriately: high-pass filtering the reference signal, precise offset tuning the reference level by low-pass filtering, and by using a voltage divider network. We assess the performance of the lock-in instrument by comparing it to a benchmark device and by determining protein concentration with single-color absorption measurements. We validate the concentration values obtained with the proposed instrument using chemical concentration measurements. Finally, we demonstrate that accurate retrieval of phase information can be achieved by using the same instrument.

  17. Assessing Management Support for Worksite Health Promotion: Psychometric Analysis of the Leading by Example (LBE) Instrument

    Science.gov (United States)

    Della, Lindsay J.; DeJoy, David M.; Goetzel, Ron Z.; Ozminkowski, Ronald J.; Wilson, Mark G.

    2009-01-01

    Objective This paper describes the development of the Leading by Example (LBE) instrument. Methods Exploratory factor analysis was used to obtain an initial factor structure. Factor validity was evaluated using confirmatory factor analysis methods. Cronbach’s alpha and item-total correlations provided information on the reliability of the factor subscales. Results Four subscales were identified: business alignment with health promotion objectives; awareness of the health-productivity link; worksite support for health promotion; leadership support for health promotion. Factor by group comparisons revealed that the initial factor structure is effective in detecting differences in organizational support for health promotion across different employee groups Conclusions Management support for health promotion can be assessed using the LBE, a brief, self-report questionnaire. Researchers can use the LBE to diagnose, track, and evaluate worksite health promotion programs. PMID:18517097

  18. DEVELOPING MUSHROOM GYMNASTIC INSTRUMENT PROTOTYPE FOR MEN’S ARTISTIC GYMNASTIC SPORT IN CENTRAL JAVA PROVINCE

    Directory of Open Access Journals (Sweden)

    Tommy Soenyoto

    2014-03-01

    Full Text Available This study aims to develop mushroom gymnastic instrument for men’s artistic gymnastic athletes of junior and senior levels. The instrument is aimed at improving movement skills on horse saddle. Aside from its use as an exercise instrument for beginner, junior and senior levels of men’s artistic gymnastic athletes, this instrument can also be used for beginners’ level competition. This study used qualitative approach in which the data are collected from the initial step to the trial. The main procedure involved five steps: (1 the analysis of product development; (2 the development of initial product; (3 the expert validation; (4 the trial; and (5 the product revision. This study found that the mushroom gymnastic instrument can be used for men’s artistic gymnastic sport, particularly (1 for improving movement skill development on horse saddle for junior and senior athletes; (2 as an exercise instrument for beginner, junior and senior level of men’s artistic gymnastic athletes; (3 as an instrument used in competition for men’s artistic gymnastic for beginners’ level.

  19. Interpreting two state instruments for intermediary values

    International Nuclear Information System (INIS)

    Good, R.R.

    1979-01-01

    Interpolating data from instruments which produce only two distinct binary outputs is discussed. The problem of determining void fraction, given an instrument which produces only a liquid or a no-liquid output, is used to demonstrate three different methods of data interpolation. The three methods involve a form of time averaging. The methods are signal amplitude histogram, signal derivative, and signal derivative discriminator. The advantages, disadvantages, and accuracies of each method are described

  20. Digital instrumentation system for nuclear research reactors

    International Nuclear Information System (INIS)

    Aghina, Mauricio A.C.; Carvalho, Paulo Vitor R.

    2002-01-01

    This work describes a proposal for a system of nuclear instrumentation and safety totally digital for the Argonauta Reactor. The system divides in the subsystems: channel of pulses, channel of current, conventional instrumentation and safety system. The connection of the subsystems is made through redundant double local net, using the protocol modbus/rtu. So much the channel of pulses, the current channel and safety's system use modules operating in triple redundancy. (author)

  1. Mass media image of selected instruments of economic develepment

    Directory of Open Access Journals (Sweden)

    Kruliš Ladislav

    2016-07-01

    Full Text Available The goal of this paper is twofold. Firstly, two instruments of economic development – investment incentives and cluster initiatives – were compared according to the frequency of their occurrence in selected mass media sources in the Czech Republic in the periods 2004-2005 and 2011-2012. Secondly, the mass media image of these two instruments of economic development was evaluated with respect to the frames deductively constructed from literature review. The findings pointed out a higher occurrence of the mass media articles/news dealing with investment incentives. These articles/news were, additionally, more controversial and covered a wider spectrum of frames. Politicians were a relatively more frequent type of actors who created the media message from the articles/news. On the contrary, the mass media articles/news concerning cluster initiatives typically created the frame of positive effects of clusters. The messages were told either by economic experts or by public authority representatives who were closely connected with cluster initiatives. Spatial origin of these messages was rather limited. The definitional vagueness, intangible and uncontroversial nature of cluster initiatives restrained their media appeal.

  2. Advanced Instrumentation for Ultrafast Science at the LCLS

    Energy Technology Data Exchange (ETDEWEB)

    Berrah, Nora [Univ. of Connecticut, Storrs, CT (United States)

    2015-10-13

    This grant supported a Single Investigator and Small Group Research (SISGR) application to enable multi-user research in Ultrafast Science using the Linac Coherent Light Source (LCLS), the world’s first hard x-ray free electron laser (FEL) which lased for the first time at 1.5 Å on April 20, 2009. The goal of our proposal was to enable a New Era of Science by requesting funds to purchase and build Advanced Instrumentation for Ultrafast Science (AIUS), to utilize the intense, short x-ray pulses produced by the LCLS. The proposed instrumentation will allow peer review selected users to probe the ultrasmall and capture the ultrafast. These tools will expand on the investment already made in the construction of the light source and its instrumentation in both the LCLS and LUSI projects. The AIUS will provide researchers in the AMO, Chemical, Biological and Condensed Matter communities with greater flexibility in defining their scientific agenda at the LCLS. The proposed instrumentation will complement and significantly augment the present AMO instrument (funded through the LCLS project) through detectors and capabilities not included in the initial suite of instrumentation at the facility. We have built all of the instrumentations and they have been utilized by scientists. Please see report attached.

  3. Particle size distribution instrument. Topical report 13

    Energy Technology Data Exchange (ETDEWEB)

    Okhuysen, W.; Gassaway, J.D.

    1995-04-01

    The development of an instrument to measure the concentration of particles in gas is described in this report. An in situ instrument was designed and constructed which sizes individual particles and counts the number of occurrences for several size classes. Although this instrument was designed to detect the size distribution of slag and seed particles generated at an experimental coal-fired magnetohydrodynamic power facility, it can be used as a nonintrusive diagnostic tool for other hostile industrial processes involving the formation and growth of particulates. Two of the techniques developed are extensions of the widely used crossed beam velocimeter, providing simultaneous measurement of the size distribution and velocity of articles.

  4. Pilot studies of management of ageing of nuclear power plant instrumentation and control components

    International Nuclear Information System (INIS)

    Burnay, S.G.; Simola, K.; Kossilov, A.; Pachner, J.

    1993-01-01

    This paper describes pilot studies which have been implemented to study the aging behavior of safety related component parts of nuclear power plants. In 1989 the IAEA initiated work on pilot studies related to the aging of such components. Four components were identified for study. They are the primary nozzle of a reactor vessel; a motor operated isolating valve; the concrete containment building; and instrumentation and control cables within the containment facility. The study was begun with phase 1 efforts directed toward understanding the aging process, and methods for monitoring and minimizing the effects of aging. Phase 2 efforts are directed toward aging studies, documentation of the ideas put forward, and research to answer questions identified in phase 1. This paper describes progress made on two of these components, namely the motor operated isolation valves, and in-containment I ampersand C cables

  5. Energy-efficiency instruments in the electricity area

    International Nuclear Information System (INIS)

    Hammer, S.; Oettli, B.; Schneider, Ch.; Iten, R.; Peherstorfer, N.

    2007-06-01

    This comprehensive report for the Swiss Federal Office of Energy (SFOE) describes a mix of instruments that could increase the efficiency of electricity usage in Switzerland. The basis for the development of these instruments - the experience gained in Europe in this area - is discussed. Explicitly not discussed are energy and electricity steering taxes, which could also be part of a future instrument-mix. The measures suggested include the setting of compulsory long-term reduction targets that are to form the basis for strategies and measures to be taken in particular areas and the development of an appropriate instrument-mix for this purpose. These could include regulations and labels, a national fund and certificate trading. Suppliers of electricity could be committed to increasing the efficiency of electricity use and national programmes could also attempt to influence consumer habits. The instruments should, according to the authors, be based on the existing legal framework and use know-how and structures that are already available

  6. Status Report on Efforts to Enhance Instrumentation to Support Advanced Test Reactor Irradiations

    Energy Technology Data Exchange (ETDEWEB)

    J. L. Rempe; D. L. Knudson; J. E. Daw

    2011-03-01

    The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support U.S. leadership in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR NSUF facilitates basic and applied nuclear research and development, further advancing the nation's energy security needs. A key component of the ATR NSUF effort is to prove new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. To address this need, an assessment of instrumentation available and under-development at other test reactors was completed. Based on this review, recommendations were made with respect to what instrumentation is needed at the ATR; and a strategy was developed for obtaining these sensors. In 2009, a report was issued documenting this program’s strategy and initial progress toward accomplishing program objectives. In 2009, a report was issued documenting this instrumentation development strategy and initial progress toward accomplishing instrumentation development program objectives. This document reports progress toward implementing this strategy in 2010.

  7. Status Report on Efforts to Enhance Instrumentation to Support Advanced Test Reactor Irradiations

    International Nuclear Information System (INIS)

    Rempe, J.L.; Knudson, D.L.; Daw, J.E.

    2011-01-01

    The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support U.S. leadership in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR NSUF facilitates basic and applied nuclear research and development, further advancing the nation's energy security needs. A key component of the ATR NSUF effort is to prove new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. To address this need, an assessment of instrumentation available and under-development at other test reactors was completed. Based on this review, recommendations were made with respect to what instrumentation is needed at the ATR; and a strategy was developed for obtaining these sensors. In 2009, a report was issued documenting this program's strategy and initial progress toward accomplishing program objectives. In 2009, a report was issued documenting this instrumentation development strategy and initial progress toward accomplishing instrumentation development program objectives. This document reports progress toward implementing this strategy in 2010.

  8. A double Gerdien instrument for simultaneous bipolar air conductivity measurements on balloon platforms.

    Science.gov (United States)

    Nicoll, K A; Harrison, R G

    2008-08-01

    A bipolar air conductivity instrument is described for use with a standard disposable meteorological radiosonde package. It is intended to provide electrical measurements at cloud boundaries, where the ratio of the bipolar air conductivities is affected by the presence of charged particles. The sensors are two identical Gerdien-type electrodes, which, through a voltage decay method, measure positive and negative air conductivities simultaneously. Voltage decay provides a thermally stable approach and a novel low current leakage electrometer switch is described which initiates the decay sequence. The radiosonde supplies power and telemetry, as well as measuring simultaneous meteorological data. A test flight using a tethered balloon determined positive (sigma(+)) and negative (sigma(-)) conductivities of sigma(+)=2.77+/-0.2 fS m(-1) and sigma(-)=2.82+/-0.2 fS m(-1), respectively, at 400 m aloft, with sigma(+)sigma(-)=0.98+/-0.04.

  9. Introduction to instrumentation and measurements

    CERN Document Server

    Northrop, Robert B

    2014-01-01

    Weighing in on the growth of innovative technologies, the adoption of new standards, and the lack of educational development as it relates to current and emerging applications, the third edition of Introduction to Instrumentation and Measurements uses the authors' 40 years of teaching experience to expound on the theory, science, and art of modern instrumentation and measurements (I&M). What's New in This Edition: This edition includes material on modern integrated circuit (IC) and photonic sensors, micro-electro-mechanical (MEM) and nano-electro-mechanical (NEM) sensors, chemical and radiation sensors, signal conditioning, noise, data interfaces, and basic digital signal processing (DSP), and upgrades every chapter with the latest advancements. It contains new material on the designs of micro-electro-mechanical (MEMS) sensors, adds two new chapters on wireless instrumentation and microsensors, and incorporates extensive biomedical examples and problems. Containing 13 chapters, this third edition: Describ...

  10. Determinants of The Application of Macro Prudential Instruments

    Directory of Open Access Journals (Sweden)

    Zakaria Firano

    2017-09-01

    Full Text Available The use of macro prudential instruments today gives rise to a major debate within the walls of central banks and other authorities in charge of financial stability. Contrary to micro prudential instruments, whose effects remain limited, macro prudential instruments are different in nature and can affect the stability of the financial system. By influencing the financial cycle and the financial structure of financial institutions, the use of such instruments should be conducted with great vigilance as well as macroeconomic and financial expertise. But the experiences of central banks in this area are sketchy, and only some emerging countries have experience using these types of instruments in different ways. This paper presents an analysis of instruments of macro prudential policy and attempts to empirically demonstrate that these instruments should be used only in specific economic and financial situations. Indeed, the results obtained, using modeling bivariate panel, confirm that these instruments are more effective when used to mitigate the euphoria of financial and economic cycles. In this sense, the output gap, describing the economic cycle, and the Z-score are the intermediate variables for the activation of capital instruments. Moreover, the liquidity ratio and changes in bank profitability are the two early warning indicators for activation of liquidity instruments.

  11. Novel Scanning Lens Instrument for Evaluating Fresnel Lens Performance: Equipment Development and Initial Results (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Herrero, R.; Miller, D. C.; Kurtz, S. R.; Anton, I.; Sala, G.

    2013-07-01

    A system dedicated to the optical transmittance characterization of Fresnel lenses has been developed at NREL, in collaboration with the UPM. The system quantifies the optical efficiency of the lens by generating a performance map. The shape of the focused spot may also be analyzed to understand change in the lens performance. The primary instrument components (lasers and CCD detector) have been characterized to confirm their capability for performing optical transmittance measurements. Measurements performed on SoG and PMMA lenses subject to a variety of indoor conditions (e.g., UV and damp heat) identified differences in the optical efficiency of the evaluated lenses, demonstrating the ability of the Scanning Lens Instrument (SLI) to distinguish between the aged lenses.

  12. CAMAC-controlled calibration system for nuclear reactor instruments

    International Nuclear Information System (INIS)

    McDowell, W.P.; Cornella, R.J.

    1977-01-01

    The hardware and the software which have been developed to implement a nuclear instrument calibration system for the Argonne National Laboratory ZPR-VI and ZPR-IX reactor complex are described. The system is implemented using an SEL-840 computer with its associated CAMAC crates and a hardware interface to generate input parameters and measure the required outputs on the instrument under test. Both linear and logarithmic instruments can be calibrated by the system and output parameters can be measured at various automatically selected values of ac line voltage. A complete report on each instrument is printed as a result of the calibration and out-of-tolerance readings are flagged. Operator interface is provided by a CAMAC-controlled Hazeltine terminal. The terminal display leads the operator through the complete calibration procedure. This computer-controlled system is a significant improvement over previously used methods of calibrating nuclear instruments since it reduces reactor downtime and allows rapid detection of long-term changes in instrument calibration

  13. Experimenting with Brass Musical Instruments.

    Science.gov (United States)

    LoPresto, Michael C.

    2003-01-01

    Describes experiments to address the properties of brass musical instruments that can be used to demonstrate sound in any level physics course. The experiments demonstrate in a quantitative fashion the effects of the mouthpiece and bell on the frequencies of sound waves and thus the musical pitches produced. (Author/NB)

  14. Authentic Performance in the Instrumental Analysis Laboratory: Building a Visible Spectrophotometer Prototype

    Science.gov (United States)

    Wilson, Mark V.; Wilson, Erin

    2017-01-01

    In this work we describe an authentic performance project for Instrumental Analysis in which students designed, built, and tested spectrophotometers made from simple components. The project addressed basic course content such as instrument design principles, UV-vis spectroscopy, and spectroscopic instrument components as well as skills such as…

  15. 40+ Years of Instrumentation for the La Silla Paranal Observatory

    Science.gov (United States)

    D'Odorico, S.

    2018-03-01

    As ESO Period 100 comes to a close, I look back at the development of ESO's instrumentation programme over more than 40 years. Instrumentation and detector activities were initially started by a small group of designers, engineers, technicians and astronomers while ESO was still at CERN in Geneva in the late 1970s. They have since led to the development of a successful suite of optical and infrared instruments for the La Silla Paranal Observatory, as testified by the continuous growth in the number of proposals for observing time and in the publications based on data from ESO telescopes. The instrumentation programme evolved significantly with the VLT and most instruments were developed by national institutes in close cooperation with ESO. This policy was a cornerstone of the VLT programme from the beginning and a key to its success.

  16. Instrumentation for collecting and measuring radon and its daughters

    International Nuclear Information System (INIS)

    Essling, M.A.; Hengde, W.; Markun, F.; Toohey, R.E.; Rundo, J.; Miranda, J.E. Jr.

    1982-01-01

    A new sampling can is described for collecting an air sample for determination of its radon content. Instruments which are employed for the continuous monitoring of radon or its daughters in houses are described and their performances discussed

  17. Survey of beam instrumentation used in SLC

    International Nuclear Information System (INIS)

    Ecklund, S.D.

    1991-03-01

    A survey of beam instruments used at SLAC in the SLC machine is presented. The basic utility and operation of each device is briefly described. The various beam instruments used at the Stanford Linear Collider (SLC), can be classified by the function they perform. Beam intensity, position and size are typical of the parameters of beam which are measured. Each type of parameter is important for adjusting or tuning the machine in order to achieve optimum performance. 39 refs

  18. Applying neural networks to optimize instrumentation performance

    Energy Technology Data Exchange (ETDEWEB)

    Start, S.E.; Peters, G.G.

    1995-06-01

    Well calibrated instrumentation is essential in providing meaningful information about the status of a plant. Signals from plant instrumentation frequently have inherent non-linearities, may be affected by environmental conditions and can therefore cause calibration difficulties for the people who maintain them. Two neural network approaches are described in this paper for improving the accuracy of a non-linear, temperature sensitive level probe ised in Expermental Breeder Reactor II (EBR-II) that was difficult to calibrate.

  19. Applying neural networks to optimize instrumentation performance

    International Nuclear Information System (INIS)

    Start, S.E.; Peters, G.G.

    1995-01-01

    Well calibrated instrumentation is essential in providing meaningful information about the status of a plant. Signals from plant instrumentation frequently have inherent non-linearities, may be affected by environmental conditions and can therefore cause calibration difficulties for the people who maintain them. Two neural network approaches are described in this paper for improving the accuracy of a non-linear, temperature sensitive level probe ised in Expermental Breeder Reactor II (EBR-II) that was difficult to calibrate

  20. Value addition initiatives for CANDU reactor operation performance

    International Nuclear Information System (INIS)

    Chugh, V.; Parmar, R.; Schut, J.; Sherin, J.; Xie, H.; Zobin, D.

    2013-01-01

    Recently, AMEC NSS initiated projects for CANDU® station performance engineering with potentially high returns for the utilities. This paper discusses three initiatives. Firstly, optimization of instrument calibration interval from 1 to 3 years will reduce time commitments on the maintenance resources on top of financial savings ~$3,500 per instrument. Secondly, reactor thermal power uncertainty assessment shows the level of operation which is believed to have an over-conservative margin that can be used to increase power by up to 0.75%. Finally, as an alternative means for controlling Reactor Inlet Header Temperature (RIHT), physical modifications to the High Pressure (HP) feedwater heaters can be useful for partially recovering RIHT resulting in increased production by 10-12 MWe. (author)

  1. Laboratory for Calibration of Gamma Radiation Measurement Instruments (LabCal) of Institute of Chemical, Biological, Radiological and Nuclear Defense (IDQBRN) from Brazilian Army Technology Center (CTEx); Laboratorio de Calibracao de Instrumentode Medicao de Radiacao Gama (LabCal) do IDQBRN do CTEx

    Energy Technology Data Exchange (ETDEWEB)

    Amorim, Aneuri de; Balthar, Mario Cesar V.; Santos, Avelino; Vilela, Paulo Ricardo T. de; Oliveira, Luciano Santa Rita; Penha, Paulo Eduardo C. de Oliveira; Gonzaga, Roberto Neves; Andrade, Edson Ramos de; Oliveira, Celio Jorge Vasques de; Fagundes, Luiz Cesar S., E-mail: aneurideamorim@gmail.com [Centro Tecnologico do Exercito (DQBRN/CTEx), Rio de Janeiro, RJ (Brazil). Instituto de Defesa Quimica, Biologica, Radiologica e Nuclear

    2016-07-01

    This paper describes the calibration laboratory deployment steps (LABCAL) gamma ionizing radiation measuring instruments in the Army Technology Center, CTEx. Initially the calibration of radiation monitors will be held in the dosimetric quantity air kerma and operational quantity ambient dose equivalent H*(d). The LABCAL / CTEx has not yet authorized by CASEC / CNEN. This laboratory aims to calibrate the ionizing radiation instruments used by the Brazilian Army. (author)

  2. The neutron instrument simulation package, NISP

    International Nuclear Information System (INIS)

    Seeger, P.A.; Daemen, L.L.

    2004-01-01

    The Neutron Instrument Simulation Package (NISP) performs complete source-to-detector simulations of neutron instruments, including neutrons that do not follow the expected path. The original user interface (MC( ) Web) is a web-based application, http://strider.lansce.lanl.gov/NISP/Welcome.html. This report describes in detail the newer standalone Windows version, NISP( ) Win. Instruments are assembled from menu-selected elements, including neutron sources, collimation and transport elements, samples, analyzers, and detectors. Magnetic field regions may also be specified for the propagation of polarized neutrons including spin precession. Either interface writes a geometry file that is used as input to the Monte Carlo engine (MC( ) Run) in the user's computer. Both the interface and the engine rely on a subroutine library, MCLIB. The package is completely open source. New features include capillary optics, temperature dependence of Al and Be, revised source files for ISIS, and visualization of neutron trajectories at run time. Also, a single-crystal sample type has been successfully imported from McStas (with more generalized geometry), demonstrating the capability of including algorithms from other sources, and NISP( ) Win may render the instrument in a virtual reality file. Results are shown for two instruments under development.

  3. Intelligent type sodium instrumentations for LMFBR

    International Nuclear Information System (INIS)

    Chen Daolong

    1996-07-01

    The constructions and performances of lots of newly developed intelligent type sodium instrumentations are described. The graduation characteristic equations for corresponding transducer using the medium temperature as the parameter are given. These intelligent type sodium instrumentations are possessed of good linearity. The accurate measurement data of sodium process parameters (flowrate, pressure and level) can be obtained by means of their on-line compensation function of the temperature effect. Moreover, these intelligent type sodium instrumentations are possessed of the self-inspection, the electric shutoff protection, the setting of full-scale, the setting of alarm limits (two upper limits and two lower limits alarms), the thermocouple breaking alarm, mutual isolative the 0∼10 V direct-current analogue output and the CENTRONICS standard digital output, and the alarm relay contact output. Theses intelligent type sodium instrumentations are suitable particularly for the instrument, control and protective systems of LMFBR by means of these excellent functions based on microprocessor. The basic errors of the intelligent type sodium flowmeter, immersed sodium flowmeter, sodium manometer and sodium level gauge are +-2%, +-2.3%, +-0.3% and +-1.9% of measuring ranges respectively. (9 figs.)

  4. Motivators to Adopt Green Supply Chain Initiatives

    OpenAIRE

    Amarpreet S. Kohli; Ellen Hawkins

    2015-01-01

    There are several factors that drive organizations to consider implementing green supply chain (GSC) initiatives. This paper refines an instrument to empirically test the significance of the following drivers for participation in GSC initiatives: Government Regulation, Buyer/Supply Chain Influence, Internal Readiness, Competitive Advantage, and Corporate Social Responsibility. Corporate Social Responsibility emerged as the most significant variable that effected the decision making of the org...

  5. Study on virtual instrument developing system based on intelligent virtual control

    International Nuclear Information System (INIS)

    Tang Baoping; Cheng Fabin; Qin Shuren

    2005-01-01

    The paper introduces a non-programming developing system of a virtual instrument (VI), i.e., a virtual measurement instrument developing system (VMIDS) based on intelligent virtual control (IVC). The background of the IVC-based VMIDS is described briefly, and the hierarchical message bus (HMB)-based software architecture of VMIDS is discussed in detail. The three parts and functions of VMIDS are introduced, and the process of non-programming developing VI is further described

  6. Study on virtual instrument developing system based on intelligent virtual control

    Energy Technology Data Exchange (ETDEWEB)

    Tang Baoping; Cheng Fabin; Qin Shuren [Test Center, College of Mechanical Engineering, Chongqing University , Chongqing 400030 (China)

    2005-01-01

    The paper introduces a non-programming developing system of a virtual instrument (VI), i.e., a virtual measurement instrument developing system (VMIDS) based on intelligent virtual control (IVC). The background of the IVC-based VMIDS is described briefly, and the hierarchical message bus (HMB)-based software architecture of VMIDS is discussed in detail. The three parts and functions of VMIDS are introduced, and the process of non-programming developing VI is further described.

  7. Holdup Measures on an SRNL Mossbauer Spectroscopy Instrument

    Energy Technology Data Exchange (ETDEWEB)

    Dewberry, R.; Brown, T.; Salaymeh, S.

    2010-05-05

    Gamma-ray holdup measurements of a Mossbauer spectroscopy instrument are described and modeled. In the qualitative acquisitions obtained in a low background area of Savannah River National Laboratory, only Am-241 and Np-237 activity were observed. The Am-241 was known to be the instrumental activation source, while the Np-237 is clearly observed as a source of contamination internal to the instrument. The two sources of activity are modeled separately in two acquisition configurations using two separate modeling tools. The results agree well, demonstrating a content of (1980 {+-} 150) {mu}Ci Am-241 and (110 {+-} 50) {mu}Ci of Np-237.

  8. A portable luminescence dating instrument

    DEFF Research Database (Denmark)

    Kook, M.H.; Murray, A.S.; Lapp, Torben

    2011-01-01

    We describe a portable luminescence reader suitable for use in remote localities in the field. The instrument weighs about 8kg and is based around a 30mm bialkali photomultiplier detecting signals through a glass filter centered on 340nm. Stimulation is by 470nm blue LEDs (24W in total) operating...

  9. Leasing instruments of high-rise construction financing

    Science.gov (United States)

    Aleksandrova, Olga; Ivleva, Elena; Sukhacheva, Viktoria; Rumyantseva, Anna

    2018-03-01

    The leasing sector of the business economics is expanding. Leasing instruments for high-rise construction financing allow to determine the best business behaviour in the leasing economy sector, not only in the sphere of transactions with equipment and vehicles. Investments in high-rise construction have a multiplicative effect. It initiates an active search and leasing instruments use in the economic behaviour of construction organizations. The study of the high-rise construction sector in the structure of the leasing market participants significantly expands the leasing system framework. The scheme of internal and external leasing process factors influence on the result formation in the leasing sector of economy is offered.

  10. Job/task analysis for I ampersand C [Instrumentation and Controls] instrument technicians at the High Flux Isotope Reactor

    International Nuclear Information System (INIS)

    Duke, L.L.

    1989-09-01

    To comply with Department of Energy Order 5480.XX (Draft), a job/task analysis was initiated by the Maintenance Management Department at Oak Ridge National Laboratory (ORNL). The analysis was applicable to instrument technicians working at the ORNL High Flux Isotope Reactor (HFIR). This document presents the procedures and results of that analysis. 2 refs., 2 figs

  11. A preview of a microgravity laser light scattering instrument

    Science.gov (United States)

    Meyer, W. V.; Ansari, R. R.

    1991-01-01

    The development of a versatile, miniature, modular light scattering instrument to be used in microgravity is described. The instrument will measure microscopic particles in the size range of thirty angstroms to above three microns. This modular instrument permits several configurations, each optimized for a particular experiment. In particular, a multiangle instrument will probably be mounted in a rack in the Space Shuttle and on the Space Station. It is possible that a Space Shuttle glove-box and a lap-top computer containing a correlator card can be used to perform a number of experiments and to demonstrate the technology needed for more elaborate investigations.

  12. Applications and experience with a new instrumented fuel element

    International Nuclear Information System (INIS)

    Morris, F.M.

    1972-01-01

    Previously reported information to TRIGA Reactor Conference I concerning the development of a new concept in an instrumented fuel element is updated and expanded. The evaluation of these new instrumented elements is discussed and some areas of application to reactor behavior are described. Experiments concerning temperature and flux mapping under varying conditions are investigated and conclusions are given. (author)

  13. High-Performance Operational and Instrumentation Amplifiers

    NARCIS (Netherlands)

    Shahi, B.

    2015-01-01

    This thesis describes techniques to reduce the offset error in precision instrumentation and operational amplifiers. The offset error which is considered a major error source associated with gain blocks, together with other errors are reviewed. Conventional and newer approaches to remove offset and

  14. Programming for a nuclear reactor instrument simulator

    International Nuclear Information System (INIS)

    Cohn, C.E.

    1989-01-01

    A new computerized control system for a transient test reactor incorporates a simulator for pre-operational testing of control programs. The part of the simulator pertinent to the discussion here consists of two microprocessors. An 8086/8087 reactor simulator calculates simulated reactor power by solving the reactor kinetics equations. An 8086 instrument simulator takes the most recent power value developed by the reactor simulator and simulates the appropriate reading on each of the eleven reactor instruments. Since the system is required to run on a one millisecond cycle, careful programming was required to take care of all eleven instruments in that short time. This note describes the special programming techniques used to attain the needed performance

  15. Advanced Technologies and Instrumentation at the National Science Foundation

    Science.gov (United States)

    Kurczynski, Peter; Neff, James E.

    2018-01-01

    Over its more than thirty-year history, the Advanced Technologies and Instrumentation (ATI) program within the Division of Astronomical Sciences has provided grants to support the development and deployment of detectors and instrumentation for ground-based astronomy. This program has enabled scientific advances in diverse fields from solar physics to exoplanets to cosmology. ATI has provided instrumentation for both small and large observatories from radio through visible wavebands. It has played a role in the early development of major initiatives such as the Large Synoptic Survey Telescope. Technology development for astronomy unfolds over a longer period than the lifetime of a single grant. This review will consider ATI from an historical perspective to assess its impact on astronomy.

  16. A standard protocol for describing individual-based and agent-based models

    Science.gov (United States)

    Grimm, Volker; Berger, Uta; Bastiansen, Finn; Eliassen, Sigrunn; Ginot, Vincent; Giske, Jarl; Goss-Custard, John; Grand, Tamara; Heinz, Simone K.; Huse, Geir; Huth, Andreas; Jepsen, Jane U.; Jorgensen, Christian; Mooij, Wolf M.; Muller, Birgit; Pe'er, Guy; Piou, Cyril; Railsback, Steven F.; Robbins, Andrew M.; Robbins, Martha M.; Rossmanith, Eva; Ruger, Nadja; Strand, Espen; Souissi, Sami; Stillman, Richard A.; Vabo, Rune; Visser, Ute; DeAngelis, Donald L.

    2006-01-01

    Simulation models that describe autonomous individual organisms (individual based models, IBM) or agents (agent-based models, ABM) have become a widely used tool, not only in ecology, but also in many other disciplines dealing with complex systems made up of autonomous entities. However, there is no standard protocol for describing such simulation models, which can make them difficult to understand and to duplicate. This paper presents a proposed standard protocol, ODD, for describing IBMs and ABMs, developed and tested by 28 modellers who cover a wide range of fields within ecology. This protocol consists of three blocks (Overview, Design concepts, and Details), which are subdivided into seven elements: Purpose, State variables and scales, Process overview and scheduling, Design concepts, Initialization, Input, and Submodels. We explain which aspects of a model should be described in each element, and we present an example to illustrate the protocol in use. In addition, 19 examples are available in an Online Appendix. We consider ODD as a first step for establishing a more detailed common format of the description of IBMs and ABMs. Once initiated, the protocol will hopefully evolve as it becomes used by a sufficiently large proportion of modellers.

  17. Pre-flight calibration and initial data processing for the ChemCam laser-induced breakdown spectroscopy instrument on the Mars Science Laboratory rover

    Science.gov (United States)

    Wiens, R.C.; Maurice, S.; Lasue, J.; Forni, O.; Anderson, R.B.; Clegg, S.; Bender, S.; Blaney, D.; Barraclough, B.L.; Cousin, A.; DeFlores, L.; Delapp, D.; Dyar, M.D.; Fabre, C.; Gasnault, O.; Lanza, N.; Mazoyer, J.; Melikechi, N.; Meslin, P.-Y.; Newsom, H.; Ollila, A.; Perez, R.; Tokar, R.; Vaniman, D.

    2013-01-01

    The ChemCam instrument package on the Mars Science Laboratory rover, Curiosity, is the first planetary science instrument to employ laser-induced breakdown spectroscopy (LIBS) to determine the compositions of geological samples on another planet. Pre-processing of the spectra involves subtracting the ambient light background, removing noise, removing the electron continuum, calibrating for the wavelength, correcting for the variable distance to the target, and applying a wavelength-dependent correction for the instrument response. Further processing of the data uses multivariate and univariate comparisons with a LIBS spectral library developed prior to launch as well as comparisons with several on-board standards post-landing. The level-2 data products include semi-quantitative abundances derived from partial least squares regression. A LIBS spectral library was developed using 69 rock standards in the form of pressed powder disks, glasses, and ceramics to minimize heterogeneity on the scale of the observation (350–550 μm dia.). The standards covered typical compositional ranges of igneous materials and also included sulfates, carbonates, and phyllosilicates. The provenance and elemental and mineralogical compositions of these standards are described. Spectral characteristics of this data set are presented, including the size distribution and integrated irradiances of the plasmas, and a proxy for plasma temperature as a function of distance from the instrument. Two laboratory-based clones of ChemCam reside in Los Alamos and Toulouse for the purpose of adding new spectra to the database as the need arises. Sensitivity to differences in wavelength correlation to spectral channels and spectral resolution has been investigated, indicating that spectral registration needs to be within half a pixel and resolution needs to match within 1.5 to 2.6 pixels. Absolute errors are tabulated for derived compositions of each major element in each standard using PLS regression

  18. Image reconstruction design of industrial CT instrument for teaching

    International Nuclear Information System (INIS)

    Zou Yongning; Cai Yufang

    2009-01-01

    Industrial CT instrument for teaching is applied to teaching and study in field of physics and radiology major, image reconstruction is an important part of software on CT instrument. The paper expatiate on CT physical theory and first generation CT reconstruction algorithm, describe scan process of industrial CT instrument for teaching; analyze image artifact as result of displacement of rotation center, implement method of center displacement correcting, design and complete image reconstruction software, application shows that reconstructed image is very clear and qualitatively high. (authors)

  19. The use of ultrasonic instrumentation in liquid/liquid extraction plant

    International Nuclear Information System (INIS)

    Asher, R.C.; Bradshaw, L.; Tolchard, A.C.

    1984-01-01

    Ultrasonic instruments can be used to determine many of the parameters of interest in a liquid/liquid extraction plant, eg liquid levels, the position of interfaces between immiscible liquids and the concentration of solutions. The determinations can often be made non-invasively. A number of instruments developed for a liquid/liquid extraction plant used for nuclear fuel reprocessing is described. These instruments have a wider application in liquid/liquid extraction plant in general. (author)

  20. Management of broken instrument by file bypass technique

    Directory of Open Access Journals (Sweden)

    Sultana Parveen

    2017-02-01

    Full Text Available Different devices and techniques have been developed to retrieve fractured instruments during the endodontic procedures. This case report describes the management of a broken instrument, which was accidentally broken during cleaning and shaping of the root canal in right 2nd molar tooth. A # 25 stainless steel K-file was separated in mesiobuccal canal of the treated tooth. At first, a radiograph was taken to confirm the level of separation of the instrument. The instrument was found to be separated at the apical 3rd of the mesial canal and then file bypass technique was performed. Calcium hydroxide dressing was given for 7 days followed by obturation with guttapercha cone and zinc oxide eugenol sealer in lateral condensation technique. It can be concluded that bypass technique can be considered as simple and effective technique for the management of broken instrument into the root canal.

  1. Performance specifications for health physics instrumentation: portable instrumentation for use in normal work environments. Part 2. Test results

    International Nuclear Information System (INIS)

    Kenoyer, J.L.; Swinth, K.L.; Stoetzel, G.A.; Selby, J.M.

    1986-09-01

    The Pacific Northwest Laboratory evaluated a draft American National Standards Institute Standard N42.17 (ANSI N42.17) on performance specifications for health physics instrumentation through a project jointly funded by the US Department of Energy and the US Nuclear Regulatory Commission. The evaluation involved testing a representative cross section of instruments against criteria in the standard. This report presents results of the testing program. A brief history of the project is included in the introduction. The instrumentation tested is described in general terms (i.e., types, ranges); however, no direct relationship between the results and a specific instrument model is made in this report. Testing requirements in ANSI N42.17D4, Revision 1 (May 1985) are summarized and the methods by which the tests are performed are discussed. Brief descriptions of the testing equipment are included in the methods section of the report. More detailed information about the draft standard, testing requirements and procedures, and the test equipment is included in ''Performance Specifications for Health Physics Instrumentation - Portable Instrumentation for Use in Normal Work Environments, Part 1: Manual of Testing Procedures.'' Results of testing are given in two formats: test-by-test and instrument-by-instrument. Discussion is included on significant and interesting findings, on comparisons of results from the same type of instruments from same and different manufacturers, and on data grouped by manufacturer. Conclusions are made on the applicability and practicality of the proposed standard and on instrument performance. Changes that have been made to the proposed standard based on findings of the testing program are listed and discussed. 22 refs., 11 figs., 77 tabs

  2. Energy-efficiency instruments in the electricity area; Instrumente fuer Energieeffizienz im Elektrizitaetsbereich. Auslaendische Erfahrungen und Instrumenten-Mix fuer die Schweiz

    Energy Technology Data Exchange (ETDEWEB)

    Hammer, S; Oettli, B; Schneider, Ch; Iten, R [Infras, Zuerich (Switzerland); Peherstorfer, N [Oesterreichische Energieagentur, Wien (Austria)

    2007-06-15

    This comprehensive report for the Swiss Federal Office of Energy (SFOE) describes a mix of instruments that could increase the efficiency of electricity usage in Switzerland. The basis for the development of these instruments - the experience gained in Europe in this area - is discussed. Explicitly not discussed are energy and electricity steering taxes, which could also be part of a future instrument-mix. The measures suggested include the setting of compulsory long-term reduction targets that are to form the basis for strategies and measures to be taken in particular areas and the development of an appropriate instrument-mix for this purpose. These could include regulations and labels, a national fund and certificate trading. Suppliers of electricity could be committed to increasing the efficiency of electricity use and national programmes could also attempt to influence consumer habits. The instruments should, according to the authors, be based on the existing legal framework and use know-how and structures that are already available.

  3. US utility I ampersand C upgrade initiative

    International Nuclear Information System (INIS)

    Wilkinson, D.

    1993-01-01

    This paper describes an initiative which is being pursued to address the problems associated with the increasing obsolescence of instrumentation and control (I ampersand C) systems in nuclear power plants. Such efforts will improve safety, availability, and reliability of plant operation. The program presented is a joint plan between EPRI, utilities, and vendors, to bring about the development of technology to meet these needs, to encourage the private sector to develop such technology, and to prove to utilities the value and utility in applying such technology to upgrade their facilities. Part of this plan is demonstration programs where plant-wide sensor and I ampersand C improvements can be implemented, in a documented manner, to provide R ampersand D information on their performance, functionality, and reliability. The intent is to reduce the costs and shorten the learning curve associated with the utilization of modern I ampersand C equipment

  4. Instrumentation and process control for fossil demonstration plants. Quarterly technical progress report, April--June 1977

    Energy Technology Data Exchange (ETDEWEB)

    LeSage, L.G.

    1977-07-01

    Work has been performed on updating the study of the state-of-the-art of instrumentation for Fossil Demonstration Plants (FDP), development of mass-flow and other on-line instruments for FDP, process control analysis for FDP, and organization of a symposium on instrumentation and control for FDP. A Solids/Gas Flow Test Facility (S/GFTF) under construction for instrument development, testing, evaluation, and calibration is described. The development work for several mass-flow and other on-line instruments is described: acoustic flowmeter, capacitive density flowmeter, neutron activation flowmeter and composition analysis system, gamma ray correlation flowmeter, optical flowmeter, and capacitive liquid interface level meter.

  5. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. An inspector-instrument interface design that allows communication of procedures, responses, and results between the instrument and user is presented. This capability has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  6. Irradiation technology (1). Development of new in-pile instrumentation at JMTR

    International Nuclear Information System (INIS)

    Shibata, Akira; Kimura, Nobuaki; Tanimoto, Masataka; Nakamura, Jinichi; Saito, Takashi; Tsuchiya, Kunihiko

    2012-01-01

    Development of instrumentation which can use under severe accident condition is important issue for the purpose to cope with severe accident at nuclear reactors. And also to improve the quality of irradiation tests data and to increase the reliability of safety management system of reactors, the development of new instrumentation is key issue. JAEA is developing several in-pile instrumentations to conduct irradiation tests at JMTR. This study includes the developments of three new instrumentations and describes the characteristics of the instrumentations. These are ECP sensor, new water level indicator and in-reactor observation system using Cherenkov light. (author)

  7. The Cambridge Otology Quality of Life Questionnaire: an otology-specific patient-recorded outcome measure. A paper describing the instrument design and a report of preliminary reliability and validity.

    Science.gov (United States)

    Martin, T P C; Moualed, D; Paul, A; Ronan, N; Tysome, J R; Donnelly, N P; Cook, R; Axon, P R

    2015-04-01

    The Cambridge Otology Quality of Life Questionnaire (COQOL) is a patient-recorded outcome measurement (PROM) designed to quantify the quality of life of patients attending otology clinics. Item-reduction model. A systematically designed long-form version (74 items) was tested with patient focus groups before being presented to adult otology patients (n. 137). Preliminary item analysis tested reliability, reducing the COQOL to 24 questions. This was then presented in conjunction with the SF-36 (V1) questionnaire to a total of 203 patients. Subsequently, these were re-presented at T + 3 months, and patients recorded whether they felt their condition had improved, deteriorated or remained the same. Non-responders were contacted by post. A correlation between COQOL scores and patient perception of change was examined to analyse content validity. Teaching hospital and university psychology department. Adult patients attending otology clinics with a wide range of otological conditions. Item reliability measured by item–total correlation, internal consistency and test– retest reliability. Validity measured by correlation between COQOL scores and patient-reported symptom change. Reliability: the COQOL showed excellent internal consistency at both initial presentation (a = 0.90) and 3 months later (a = 0.93). Validity: One-way analysis of variance showed a significant difference between groups reporting change and those reporting no change in quality of life (F(2, 80) = 5.866, P < 0.01). The COQOL is the first otology-specific PROM. Initial studies demonstrate excellent reliability and encouraging preliminary criterion validity: further studies will allow a deeper validation of the instrument.

  8. Student Evaluation of Teaching: An Instrument and a Development Process

    Science.gov (United States)

    Alok, Kumar

    2011-01-01

    This article describes the process of faculty-led development of a student evaluation of teaching instrument at Centurion School of Rural Enterprise Management, a management institute in India. The instrument was to focus on teacher behaviors that students get an opportunity to observe. Teachers and students jointly contributed a number of…

  9. Total dose tests for the PROMICS-3 instrument

    International Nuclear Information System (INIS)

    Verkasalo, R.

    1991-01-01

    The sensitivity of some analog and digital integrated circuits (IC's) to ionizing radiation was tested in order to evaluate their potential usefulness especially in the PROMICS-3 instrument. The PROMICS-3 is a plasma instrument to be flown on the Russian Interball satellites. The radiation tolerance requirement of the auroral Interball satellite is about 45 krad/year inside a shielding of 4 mm Aluminium. The IC's tested were: AD571 A/D- converter, ADDAC80 D/A-converter, LF442A and PM108A operational amplifiers, MPREF0l voltage reference, STC SPXO 6 MHZ oscillator,4N55 optocoupler, MC5lC98 and CY7C164 16k*4 static CMOS RAM. Co-60 was used as the irradiation source. The test methods and results are described in the paper. The RAM-circuits failed between 10 and 20 krad. D/A- and A/D-converters degraded only slightly after 100 krad, but one of the A/D-converters failed functionally at 190 krad. The LF442A began to degrade in the test connection at 100 krad, and PM108A at 30 krad. The output voltage of the voltage reference MPREF01 increased about 20 mV after 100 krad. No change was observed in the output frequency of the STC SPXD oscillator even after 300 krad. The current tansfer ratio of the 4N55 decreased continuously to about 75 % of the initial value after 100 krad

  10. Development of intelligent system for a thermal analysis instrument

    International Nuclear Information System (INIS)

    Xu Xiaoli; Wu Guoxin; Shi Yongchao

    2005-01-01

    The key techniques for the intelligent analysis instrument developed are proposed. Based on the technique of virtual instrumentation, the intelligent PID control algorithm to control the temperature of thermal analysis instrument is described. The dynamic character and the robust performance of traditional PID controls are improved through the dynamic gain factor, temperature rate change factor, the forecast factor, and the temperature correction factor is introduced. Using the graphic development environment of LabVIEW, the design of system modularization and the graphic display are implemented. By means of multiple mathematical modules, intelligent data processing is realized

  11. An instrument for X-ray set quality assurance measurements

    International Nuclear Information System (INIS)

    Willetts, R.J.; West, M.B.; Brydon, J.

    1989-01-01

    This paper describes a prototype electronic instrument for performing quality assurance (QA) measurements on diagnostic radiological equipment with a view to long-term performance assessment on a Regional basis. The instrument is based on a Tandy 200 laptop computer and has been developed primarily to include the assessment of image intensifier/TV systems in a general QA package. It is capable of accepting signals from the following sources: (1) a radiation detector (diode array); (2) a Keithley kV divider (Keithley Instruments, Inc.); (3) the video output of an image intensifier system. (author)

  12. Prospects for the applications of computer in the field of domestic nuclear medicinal instrument

    International Nuclear Information System (INIS)

    Zhao Changhe

    1993-01-01

    The current situation and prospects about domestic nuclear medical instrument, as well as the comparisons of computer application in nuclear medical instruments with in other medical instruments from various points of view have all been described in the paper

  13. Nuclear instrumentation for research reactors; Instrumentacion nuclear para reactores nucleares de investigacion

    Energy Technology Data Exchange (ETDEWEB)

    Hofer, Carlos G.; Pita, Antonio; Verrastro, Claudio A.; Maino, Eduardo J. [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Unidad de Actividades de Reactores y Centrales Nucleares. Sector Instrumentacion y Control

    1997-10-01

    The nuclear instrumentation for research reactors in Argentina was developed in 70`. A gradual modernization of all the nuclear instrumentation is planned. It includes start-up and power range instrumentation, as well as field monitors, clamp, scram and rod movement control logic. The new instrumentation is linked to a computer network, based on real time operating system for data acquisition, display and logging. This paper describes the modules and whole system aspects. (author). 2 refs.

  14. Strengthening the Idea of “By Citizens, for Citizens” in the Context of the European Citizens' Initiative - Brief Analysis of Initiatives

    Directory of Open Access Journals (Sweden)

    Oana - Măriuca Petrescu

    2014-06-01

    Full Text Available Regulation (EU No. 211 of 16 February 2011 on the European Citizens' Initiative (ECI, as one of the major innovations of the Treaty of Lisbon, represents the first supranational instrument of direct democracy that took effect on April 1, 2012, creating the direct legal link between the European Union citizens and the European institutions. Within the present paper we will give a general overview of the European Citizens’ Initiative instrument, trying also to analyse briefly certain citizens’ initiatives that have been already registered on the European Commission’s website where the online collection of a million signatures is still running, bearing in mind the important role of the citizens as “co-authors” of the law within the European decision-making process. From our point of view this participation will increase the responsibility of the citizens to be more active and to use their new right in the best conditions and without any obstacles.

  15. Geotechnical instrumentation requirements for at-depth testing and repository monitoring in tuff

    International Nuclear Information System (INIS)

    Zimmerman, R.M.

    1982-01-01

    Minimum required geotechnical measurements for confirmation of repository performance include thermal and thermomechanical responses; changes in stress, strain, and displacements; and pore pressure and groundwater flow characteristics. Conditions expected in tuff are: maximum rock temperatures of less than 250 0 C, stresses less than 100 MPa, strains between +-0.01 mm/mm, and pore pressures less than 35 KPa in the unsaturated zone where hydraulic head is not the primary contributor. The paper describes instrumentation needed to make the desired measurements. In general, the instrumentation and data system are required to be stable and reliable for tens of years. Designs must consider requirements for temperature stability, temperature expansion compensation, moisture resistance, and long-term durability in mining-type environments. Severe requirements such as these suggest consideration of techniques for in-situ replacement of instrumentation. State-of-the-art instrumentation is briefly described along with a discussion of needs for refinement, replacement/recalibration and instrumentation development

  16. The Breakthrough Listen Initiative and the Future of the Search for Intelligent Life

    Science.gov (United States)

    Enriquez, J. Emilio; Siemion, Andrew; Croft, Steve; Hellbourg, Greg; Lebofsky, Matt; MacMahon, David; Price, Danny; DeBoer, David; Werthimer, Dan

    2017-05-01

    Unprecedented recent results in the fields of exoplanets and astrobiology have dramatically increased the interest in the potential existence of intelligent life elsewhere in the galaxy. Additionally, the capabilities of modern Searches for Extraterrestrial Intelligence (SETI) have increased tremendously. Much of this improvement is due to the ongoing development of wide bandwidth radio instruments and the Moore's Law increase in computing power over the previous decades. Together, these instrumentation improvements allow for narrow band signal searches of billions of frequency channels at once.The Breakthrough Listen Initiative (BL) was launched on July 20, 2015 at the Royal Society in London, UK with the goal to conduct the most comprehensive and sensitive search for advanced life in humanity's history. Here we detail important milestones achieved during the first year and a half of the program. We describe the key BL SETI surveys and briefly describe current facilities, including the Green Bank Telescope, the Automated Planet Finder and the Parkes Observatory. We also mention the ongoing and potential collaborations focused on complementary sciences, these include pulse searches of pulsars and FRBs, as well as astrophysically powered radio emission from stars targeted by our program.We conclude with a brief view towards future SETI searches with upcoming next-generation radio facilities such as SKA and ngVLA.

  17. Development of quality of life instrument for urban poor in the northeast of Thailand.

    Science.gov (United States)

    Surit, Phrutthinun; Laohasiriwong, Wongsa; Sanchaisuriya, Pattara; Schelp, Frank Perter

    2008-09-01

    Measuring the quality of life is important for evaluation and prediction of life and social care needs. To evaluate Quality of Life (QOL) in an urban poor population in northeast of Thailand, the Urban Poor Quality of Life (UPQOL) instrument was developed To develop an initial instrument to measure urban poor QOL. The development was started with literature review and investigated in urban poor communities. The results were transformed into the items required to build a structured questionnaire. Five hundred twenty three subjects, representatives of urban poor, were selected to test this instrument. Descriptive statistics described feature of items and the samples, exploratory factor analysis conducted the items score, and confirmatory factor analysis conducted the construct validity. The result found that the UPQOL instrument consisted of nine domains (education, income and employment, environment, health, infrastructure, security and safety, shelter and housing, civil society and political, and human rights domains) with egien value rank from 1.5 to 4.2 and 61 items with the factor loading rank from 0.41 to 0.82. The internal consistency was 0.92. The correlation between items to domain ranged from 0.30 to 0.72 and domains to overall QOL ranged from 0.27 to 0.84. Confirmatory factor analysis showed that the structure fit all domains well. Domains and overall structure were good with CFI (> 0.95). The internal consistency value ranged from 0.73-0.93. UPQOL scores were able to discriminate groups of subjects with differences levels of QOL. The UPQOL instrument is conceptually valid. The results support good validity and reliability. It forms the basis for future testing and application in other settings.

  18. The Friedrich-Lively Instrument to Assess the Impact of Schizophrenia on Siblings (FLIISS): Part I--instrument construction.

    Science.gov (United States)

    Friedrich, Rose Marie; Lively, Sonja; Rubenstein, Linda; Buckwalter, Kathleen

    2002-01-01

    Siblings of persons with schizophrenia may provide primary or secondary care for their sibling and support to parents who are primary care givers. These siblings experience stress and the accompanying sequelae of decreased quality of life, grief, chronic illness, and symptoms of depression and anxiety. Comprehensive measures of sibling stress have not been published. Before interventions to help siblings can be created, health professionals need such an assessment. The Friedrich-Lively Instrument to Assess the Impact of Schizophrenia on Siblings (FLIISS) has been developed to meet the needs of both health workers and siblings. The instrument has a strong conceptual basis adapted from Pearlin's model of stress in caregiving and was preceded by pilot work that evaluated both quantitative and qualitative data. In this article, (Part I), the development of the instrument and its relationships to the conceptual model are described. Health professionals can use the instrument for collecting information that will increase their ability to identify sources of stress faced by siblings of persons with schizophrenia, and from this assessment they may develop interventions for this underserved population.

  19. SALSA-A new instrument for strain imaging in engineering materials and components

    International Nuclear Information System (INIS)

    Pirling, Thilo; Bruno, Giovanni; Withers, Philip J.

    2006-01-01

    Residual stresses are very hard to predict and if undetected can lead to premature failure or unexpected behaviour of engineering materials or components. This paper describes the operation of a new residual strain-mapping instrument, Strain Analyser for Large and Small scale engineering Applications (SALSA), recently commissioned at the public user facility, the Institut Laue-Langevin in Grenoble, France. A unique feature of this neutron diffraction instrument is the sample manipulator, which is the first of its kind, allowing precise scanning of large and heavy (<500 kg) samples along any trajectory involving translations, tilts and rotations. Other notable features of the instrument are also described

  20. Easy instrumental analysis

    International Nuclear Information System (INIS)

    Ko, Myeong Su; Kim, Tae Hwa; Park, Gyu Hyeon; Yang, Jong Beom; Oh, Chang Hwan; Lee, Kyoung Hye

    2010-04-01

    This textbook describes instrument analysis in easy way with twelve chapters. The contents of the book are pH measurement on principle, pH meter, pH measurement, examples of the experiments, centrifugation, Absorptiometry, Fluorescent method, Atomic absorption analysis, Gas-chromatography, Gas chromatography-mass spectrometry, High performance liquid chromatography liquid chromatograph-mass spectrometry, Electrophoresis on practical case and analysis of the result and examples, PCR on principle, device, application and examples and Enzyme-linked immunosorbent assay with indirect ELISA, sandwich ELISA and ELISA reader.

  1. Easy instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Myeong Su; Kim, Tae Hwa; Park, Gyu Hyeon; Yang, Jong Beom; Oh, Chang Hwan; Lee, Kyoung Hye

    2010-04-15

    This textbook describes instrument analysis in easy way with twelve chapters. The contents of the book are pH measurement on principle, pH meter, pH measurement, examples of the experiments, centrifugation, Absorptiometry, Fluorescent method, Atomic absorption analysis, Gas-chromatography, Gas chromatography-mass spectrometry, High performance liquid chromatography liquid chromatograph-mass spectrometry, Electrophoresis on practical case and analysis of the result and examples, PCR on principle, device, application and examples and Enzyme-linked immunosorbent assay with indirect ELISA, sandwich ELISA and ELISA reader.

  2. Instrumental nuclear physics: elements for a proper choice

    International Nuclear Information System (INIS)

    1994-01-01

    This report consists of 11 documents about instrumental nuclear physics. It describes several detectors and data analysis techniques. Separate abstracts were prepared for all the papers in this volume. (TEC)

  3. RESPONSE OF NIGERIAN CASSAVA EXPANSION INITIATIVES TO CLIMATE CHANGES, ECONOMIC GROWTH AND SOME POLICY INSTRUMENT (1970-2012

    Directory of Open Access Journals (Sweden)

    Onwumere Joseph

    2013-10-01

    Full Text Available This study considered the limiting response of Nigeria cassava expansion initiative to climate changes, economic growth and some policy instruments. The presidential initiative to make cassava a foreign exchange earner as well as ensuring that national demand are satisfied has made cassava a significant economic crop and resource input of industrial and international status. Currently, its derivatives such as animal feed, starch, ethanol, cassava chip, cassava flour, cassava liquor etc are in high demand. Having gained international recognition some factors need be examined to ascertain the limiting response of this economic crop some exogenous factors. The specific objectives of interest were to ascertain the response of cassava output expansion to rainfall, temperature, imports, exports, credit allocation to agribusiness, exchange rate, nominal interest rate, inflation and GDP from 1970 – 2012. Also, it examined the short and long run effects of these variables to cassava output so as to know how much adjustment it makes to reach the equilibrium. Secondary data were used for this research work. The technique of data analysis was auto- regressive modeling regression. To capture the long run and short run dynamics of cassava output behavior, the error correction model (ECM using the Engle-Granger methodology was adopted. The result revealed a very high rate of adjustment to long run equilibrium and the variables are correlated which means that impact of each variable on cassava output behavior in the economy is inseparable. The Error correction coefficient of -0.975 measures the speed of adjustment towards long run equilibrium earned the expected negative sign and is statistically significant at 1% risk level. Thus, this study recommends that the emerging cassava economy of Nigeria would be adequately empowered for efficient productivity if the Government stipulate policies that will encourage domestic output expansion to meet the national and

  4. Dynamic surface-pressure instrumentation for rods in parallel flow

    International Nuclear Information System (INIS)

    Mulcahy, T.M.; Lawrence, W.

    1979-01-01

    Methods employed and experience gained in measuring random fluid boundary layer pressures on the surface of a small diameter cylindrical rod subject to dense, nonhomogeneous, turbulent, parallel flow in a relatively noise-contaminated flow loop are described. Emphasis is placed on identification of instrumentation problems; description of transducer construction, mounting, and waterproofing; and the pretest calibration required to achieve instrumentation capable of reliable data acquisition

  5. Musical Instrument Classification Based on Nonlinear Recurrence Analysis and Supervised Learning

    Directory of Open Access Journals (Sweden)

    R.Rui

    2013-04-01

    Full Text Available In this paper, the phase space reconstruction of time series produced by different instruments is discussed based on the nonlinear dynamic theory. The dense ratio, a novel quantitative recurrence parameter, is proposed to describe the difference of wind instruments, stringed instruments and keyboard instruments in the phase space by analyzing the recursive property of every instrument. Furthermore, a novel supervised learning algorithm for automatic classification of individual musical instrument signals is addressed deriving from the idea of supervised non-negative matrix factorization (NMF algorithm. In our approach, the orthogonal basis matrix could be obtained without updating the matrix iteratively, which NMF is unable to do. The experimental results indicate that the accuracy of the proposed method is improved by 3% comparing with the conventional features in the individual instrument classification.

  6. The measurement of inclination on gravity concrete dams using the tiltmeter instrument

    OpenAIRE

    Radovanović Slobodan D.; Brajović Ljiljana M.; Pavić Maja L.; Đurić Srđan S.; Ranđelović Sanja D.; Milivojević Vladimir J.

    2015-01-01

    The measurement of inclination on gravity concrete dams using the instrument tiltmeter is described and discussed with special reference on obtained results on the dam 'Đerdap 2' acquired in the three years period. Tiltmetar way of operation is presented both through physical principle of vibrating wire sensors and through described design of the instrument. The influence of the temperature on the measurement of the slope is specially emphasized and presented through temperature correction. P...

  7. Instrument performance and simulation verification of the POLAR detector

    Science.gov (United States)

    Kole, M.; Li, Z. H.; Produit, N.; Tymieniecka, T.; Zhang, J.; Zwolinska, A.; Bao, T. W.; Bernasconi, T.; Cadoux, F.; Feng, M. Z.; Gauvin, N.; Hajdas, W.; Kong, S. W.; Li, H. C.; Li, L.; Liu, X.; Marcinkowski, R.; Orsi, S.; Pohl, M.; Rybka, D.; Sun, J. C.; Song, L. M.; Szabelski, J.; Wang, R. J.; Wang, Y. H.; Wen, X.; Wu, B. B.; Wu, X.; Xiao, H. L.; Xiong, S. L.; Zhang, L.; Zhang, L. Y.; Zhang, S. N.; Zhang, X. F.; Zhang, Y. J.; Zhao, Y.

    2017-11-01

    POLAR is a new satellite-born detector aiming to measure the polarization of an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of September 2016, is designed to measure the polarization of the hard X-ray flux by measuring the distribution of the azimuthal scattering angles of the incoming photons. A detailed understanding of the polarimeter and specifically of the systematic effects induced by the instrument's non-uniformity are required for this purpose. In order to study the instrument's response to polarization, POLAR underwent a beam test at the European Synchrotron Radiation Facility in France. In this paper both the beam test and the instrument performance will be described. This is followed by an overview of the Monte Carlo simulation tools developed for the instrument. Finally a comparison of the measured and simulated instrument performance will be provided and the instrument response to polarization will be presented.

  8. Integrated safeguards testing laboratories in support of the advanced fuel cycle initiative

    International Nuclear Information System (INIS)

    Santi, Peter A.; Demuth, Scott F.; Klasky, Kristen L.; Lee, Haeok; Miller, Michael C.; Sprinkle, James K.; Tobin, Stephen J.; Williams, Bradley

    2009-01-01

    A key enabler for advanced fuel cycle safeguards research and technology development for programs such as the Advanced Fuel Cycle Initiative (AFCI) is access to facilities and nuclear materials. This access is necessary in many cases in order to ensure that advanced safeguards techniques and technologies meet the measurement needs for which they were designed. One such crucial facility is a hot cell based laboratory which would allow developers from universities, national laboratories, and commercial companies to perform iterative research and development of advanced safeguards instrumentation under realistic operating conditions but not be subject to production schedule limitations. The need for such a facility arises from the requirement to accurately measure minor actinide and/or fission product bearing nuclear materials that cannot be adequately shielded in glove boxes. With the contraction of the DOE nuclear complex following the end of the cold war, many suitable facilities at DOE sites are increasingly costly to operate and are being evaluated for closure. A hot cell based laboratory that allowed developers to install and remove instrumentation from the hot cell would allow for both risk mitigation and performance optimization of the instrumentation prior to fielding equipment in facilities where maintenance and repair of the instrumentation is difficult or impossible. These benefits are accomplished by providing developers the opportunity to iterate between testing the performance of the instrumentation by measuring realistic types and amounts of nuclear material, and adjusting and refining the instrumentation based on the results of these measurements. In this paper, we review the requirements for such a facility using the Wing 9 hot cells in the Los Alamos National Laboratory's Chemistry and Metallurgy Research facility as a model for such a facility and describe recent use of these hot cells in support of AFCI.

  9. Integrated safeguards testing laboratories in support of the advanced fuel cycle initiative

    Energy Technology Data Exchange (ETDEWEB)

    Santi, Peter A [Los Alamos National Laboratory; Demuth, Scott F [Los Alamos National Laboratory; Klasky, Kristen L [Los Alamos National Laboratory; Lee, Haeok [Los Alamos National Laboratory; Miller, Michael C [Los Alamos National Laboratory; Sprinkle, James K [Los Alamos National Laboratory; Tobin, Stephen J [Los Alamos National Laboratory; Williams, Bradley [DOE, NE

    2009-01-01

    A key enabler for advanced fuel cycle safeguards research and technology development for programs such as the Advanced Fuel Cycle Initiative (AFCI) is access to facilities and nuclear materials. This access is necessary in many cases in order to ensure that advanced safeguards techniques and technologies meet the measurement needs for which they were designed. One such crucial facility is a hot cell based laboratory which would allow developers from universities, national laboratories, and commercial companies to perform iterative research and development of advanced safeguards instrumentation under realistic operating conditions but not be subject to production schedule limitations. The need for such a facility arises from the requirement to accurately measure minor actinide and/or fission product bearing nuclear materials that cannot be adequately shielded in glove boxes. With the contraction of the DOE nuclear complex following the end of the cold war, many suitable facilities at DOE sites are increasingly costly to operate and are being evaluated for closure. A hot cell based laboratory that allowed developers to install and remove instrumentation from the hot cell would allow for both risk mitigation and performance optimization of the instrumentation prior to fielding equipment in facilities where maintenance and repair of the instrumentation is difficult or impossible. These benefits are accomplished by providing developers the opportunity to iterate between testing the performance of the instrumentation by measuring realistic types and amounts of nuclear material, and adjusting and refining the instrumentation based on the results of these measurements. In this paper, we review the requirements for such a facility using the Wing 9 hot cells in the Los Alamos National Laboratory's Chemistry and Metallurgy Research facility as a model for such a facility and describe recent use of these hot cells in support of AFCI.

  10. Rotor instrumentation circuits for the Sandia 34-meter vertical axis wind turbine

    Science.gov (United States)

    Sutherland, Herbert J.; Stephenson, William A.

    1988-07-01

    Sandia National Laboratories has erected a research oriented, 34-meter diameter, Darrieus vertical axis wind turbine near Bushland, Texas, which has been designated the Sandia 34-m VAWT Test Bed. To meet present and future research needs, the machine was equipped with a large array of sensors. This manuscript details the sensors initially placed on the rotor, their respective instrumentation circuits, and the provisions incorporated into the design of the rotor instrumentation circuits for future research. This manuscript was written as a reference manual for the rotor instrumentation of the Test Bed.

  11. Monte Carlo simulation of neutron scattering instruments

    International Nuclear Information System (INIS)

    Seeger, P.A.

    1995-01-01

    A library of Monte Carlo subroutines has been developed for the purpose of design of neutron scattering instruments. Using small-angle scattering as an example, the philosophy and structure of the library are described and the programs are used to compare instruments at continuous wave (CW) and long-pulse spallation source (LPSS) neutron facilities. The Monte Carlo results give a count-rate gain of a factor between 2 and 4 using time-of-flight analysis. This is comparable to scaling arguments based on the ratio of wavelength bandwidth to resolution width

  12. Extrinsic Motivators Affecting Fourth-Grade Students' Interest and Enrollment in an Instrumental Music Program

    Science.gov (United States)

    Vasil, Martina

    2013-01-01

    The purpose of this study was to investigate fourth-grade students' extrinsic motivators for joining and continuing in a school instrumental music program. Three research questions were investigated: (a) What extrinsic motivators have influenced fourth-grade students' initial interest and continuing participation in an instrumental music program?…

  13. Geotechnical instrumentation requirements for atdepth testing and repository monitoring in tuff

    International Nuclear Information System (INIS)

    Zimmerman, R.M.

    1983-01-01

    This paper outlines geotechnical instrumentation requirements for the possible establishment of a nuclear waste repository in tuff on the Nevada Test Site (NTS). The Nuclear Regulatory Commission (NRC) has specified a continuing program to confirm performance during the operational period of the repository, which could last 50 years. Minimum required geotechnical measurements for confirmation of performance include thermal and thermomechanical responses; changes in stress, strain, and displacements; and pore pressure and groundwater flow characteristics. Conditions expected in tuff are: maximum rock temperatures of less than 250 0 C, stresses less than 100 MPa, strains between + or -0.01 mm/mm, and pore pressures less than 35 KPa in the unsaturated zone where hydraulic head is not the primary contributor. The paper describes instrumentation needed to make the desired measurements. In general, the instrumentation and data system are required to be stable and reliable for tens of years. Designs must consider requirements for temperature stability, temperature expansion compensation, moisture resistance, and long-term durability in mining-type environments. Severe requirements such as these suggest consideration of techniques for in-situ replacement of instrumentation. State-of-the-art instrumentation is briefly described along with a discussion of needs for refinement, replacement/recalibration and instrumentation development

  14. Tamper indicating radiation surveillance instrumentation

    International Nuclear Information System (INIS)

    Chambers, W.H.; Ney, J.F.

    1975-01-01

    Prototype personnel and shipping dock portal monitors suitable for unattended use were fabricated and tested. The requirement for continuous operation with only periodic inspection along with a desire for minimum costs and minimum interference with normal plant operation imposed unique design constraints. The design, operation, and performance of the detection and data recording instrumentation are described, as well as the tamper indicating techniques required to protect the collected data. The essential elements of either of the two instruments include a gamma detector array, signal conditioning electronics, digital alarm logic circuitry, power supplies, a microwave occupancy monitor, surveillance camera, irreversible electromechanical counters, and the appropriate tamper indicating envelope protecting these elements. Attempts to penetrate the tamper indicating envelope require material removal, and undetectable repair is very difficult, if not impossible. The techniques for joining major subassemblies and providing unique seals are also described. The personnel doorway uses a double pole array of NaI(Tl) detectors, and outputs are taken from a single channel pulse height analyzer with a window set at 60 to 250 keV and the lower level discriminator at greater than 60 keV. A sliding interval counter is used to make comparisons to an accumulated background at the 4sigma level. Logic design, sensitivity for special nuclear materials, false alarm data, and test procedures are described in detail. The shipping dock monitor had different design constraints and therefore uses a single, long, cylindrical plastic scintillator. Some differences in signal conditioning and processing are also described. (auth)

  15. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  16. Measurement properties of adult quality-of-life measurement instruments for eczema: protocol for a systematic review.

    Science.gov (United States)

    Apfelbacher, Christian J; Heinl, Daniel; Prinsen, Cecilia A C; Deckert, Stefanie; Chalmers, Joanne; Ofenloch, Robert; Humphreys, Rosemary; Sach, Tracey; Chamlin, Sarah; Schmitt, Jochen

    2015-04-16

    Eczema is a common chronic or chronically relapsing skin disease that has a substantial impact on quality of life (QoL). By means of a consensus-based process, the Harmonising Outcome Measures in Eczema (HOME) initiative has identified QoL as one of the four core outcome domains to be assessed in all eczema trials (Allergy 67(9):1111-7, 2012). Various measurement instruments exist to measure QoL in adults with eczema, but there is a great variability in both content and quality (for example, reliability and validity) of the instruments used, and it is not always clear if the best instrument is being used. Therefore, the aim of the proposed research is a comprehensive systematic assessment of the measurement properties of the existing measurement instruments that were developed and/or validated for the measurement of patient-reported QoL in adults with eczema. This study is a systematic review of the measurement properties of patient-reported measures of QoL developed and/or validated for adults with eczema. Medline via PubMed and EMBASE will be searched using a selection of relevant search terms. Eligible studies will be primary empirical studies evaluating, describing, or comparing measurement properties of QoL instruments for adult patients with eczema. Eligibility assessment and data abstraction will be performed independently by two reviewers. Evidence tables will be generated for study characteristics, instrument characteristics, measurement properties, and interpretability. The quality of the measurement properties will be assessed using predefined criteria. Methodological quality of studies will be assessed using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. A best evidence synthesis will be undertaken if more than one study has investigated a particular measurement property. The proposed systematic review will produce a comprehensive assessment of measurement properties of existing QoL instruments in

  17. [work motivation -- assessment instruments and their relevance for medical care].

    Science.gov (United States)

    Fiedler, Rolf G; Ranft, Andreas; Greitemann, Bernhard; Heuft, Gereon

    2005-11-01

    The relevance of work motivation for medical research and healthcare, in particular rehabilitation, is described. Four diagnostic instruments in the German language are introduced which can assess work motivation using a scale system: AVEM, JDS, LMI and FBTM. Their possible application and potential usage for the clinical area are discussed. Apart from the FBTM, none of these instruments can be directly used as a general instrument in a normal medical clinical setting. Finally, a current model for work motivation (compensatory model of work motivation and volition) is presented that contains basis concepts, which are judged as important for future research questions concerning the development of motivation diagnostic instruments.

  18. Enabling instrumentation and technology for 21st century light sources

    Energy Technology Data Exchange (ETDEWEB)

    Byrd, J.M.; Shea, T.J.; Denes, P.; Siddons, P.; Attwood, D.; Kaertner, F.; Moog, L.; Li, Y.; Sakdinawat, A.; Schlueter, R.

    2010-06-01

    We present the summary from the Accelerator Instrumentation and Technology working group, one of the five working groups that participated in the BES-sponsored Workshop on Accelerator Physics of Future Light Sources held in Gaithersburg, MD September 15-17, 2009. We describe progress and potential in three areas: attosecond instrumentation, photon detectors for user experiments, and insertion devices.

  19. Standardization of portable assay instrumentation: the neutron-coincidence tree

    International Nuclear Information System (INIS)

    Menlove, H.O.

    1983-01-01

    Standardization of portable neutron assay instrumentation has been achieved by using the neutron coincidence technique as a common basis for a wide range of instruments and applications. The electronics originally developed for the High-Level Neutron Coincidence Counter has been adapted to both passive- and active-assay instrumentation for field verification of bulk plutonium, inventory samples, pellets, powders, nitrates, high-enriched uranium, and materials-testing-reactor, light-water-reactor, and mixed-oxide fuel assemblies. The family of detectors developed at Los Alamos National Laboratory and their performance under in-field conditions are described. 16 figures, 3 tables

  20. Assessment of Work Performance (AWP)--development of an instrument.

    Science.gov (United States)

    Sandqvist, Jan L; Törnquist, Kristina B; Henriksson, Chris M

    2006-01-01

    Adequate work assessments are a matter of importance both for individuals and society [5,29,31,38,40,46,52]. However, there is a lack of adequate and reliable instruments for use in work rehabilitation [14,15,20,21,31,44]. The purpose of this study was to develop and evaluate an observation instrument for assessing work performance, the AWP (Assessment of Work Performance). The purpose of the 14-item instrument is to assess the individual's observable working skills in three different areas: motor skills, process skills, and communication and interaction skills. This article describes the development and results of preliminary testing of the AWP. The testing indicates a satisfactory face validity and utility for the AWP and supports further research and testing of the instrument.

  1. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  2. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  3. Development of a Self-Rating instrument to Measure Team Situation Awareness

    NARCIS (Netherlands)

    Schraagen, J.M.C.; Koning, L. de; Hof, T.; Dongen, K. van

    2010-01-01

    The goal of this paper is to describe the development of an instrument to measure team situation awareness (TSA). Individual team member SA may or may not be shared through communication processes with other team members. Most existing instruments do not measure these processes but measure TSA as a

  4. The cross-cultural equivalence of participation instruments: a systematic review.

    Science.gov (United States)

    Stevelink, S A M; van Brakel, W H

    2013-07-01

    be used to ensure comprehensive reporting of the validation (equivalence) testing process and its results. • Participation instruments are often used in a different cultural setting than initial developed for. • The conceptualization of participation may vary across cultures. Therefore, cultural equivalence – the extent to which an instrument is equally suitable for use in two or more cultures – is an important concept to address. • This review showed that the process of cultural equivalence testing of the included participation instruments was often addressed insufficiently. • Clinicians should be aware that application of participations instruments in a different culture than initially developed for needs prior testing of cultural validity in the next context.

  5. Geotechnical instrumentation for repository shafts

    International Nuclear Information System (INIS)

    Lentell, R.L.; Byrne, J.

    1993-01-01

    The US Congress passed the Nuclear Waste Policy Act in 1980, which required that three distinctly different geologic media be investigated as potential candidate sites for the permanent disposal of high-level nuclear waste. The three media that were selected for study were basalt (WA), salt (TX, LA, MS, UT), and tuff (NV). Preliminary Exploratory Shaft Facilities (ESF) designs were prepared for seven candidate salt sites, including bedded and domal salt environments. A bedded-salt site was selected in Deaf Smith County, TX for detailed site characterization studies and ESF Final Design. Although Congress terminated the Salt Repository Program in 1988, Final Design for the Deaf Smith ESF was completed, and much of the design rationale can be applied to subsequent deep repository shafts. This paper presents the rationale for the geotechnical instrumentation that was designed for construction and operational performance monitoring of the deep shafts of the in-situ test facility. The instrumentation design described herein can be used as a general framework in designing subsequent instrumentation programs for future high-level nuclear waste repository shafts

  6. Small-angle neutron scattering instrument at MINT

    International Nuclear Information System (INIS)

    Mohd Ali Sufi; Yusof Abdullah; Razali Kassim; Hamid; Shahidan Radiman; Mohammad Deraman; Abdul Ghaffar Ramli

    1996-01-01

    The Small Angle Neutron Scattering (SANS) Instrument has been developed at Malaysian Institute for Nuclear Technology Research (MINT) for studying structural properties of materials on the length scale 1 nm to 100 nm. This is the length scale which is relevant for many topics within soft condensed matter, like polymers, colloids, biological macromolecules, etc. The SANS is a complementary technique to X-ray and electron scattering. However, while these later techniques give information on structures near surface, SANS concerns the structure of the bulk. Samples studied by SANS technique are typically bulk materials of the sizes mm's to cm's, or materials dissolved in a liquid. This paper described the general characteristics of SANS instrument as well as the experimental formulation in neutron scattering. The preliminary results obtained by this instrument are shown

  7. Cultural validation of a new instrument to measure leprosy-related stigma: the SARI Stigma Scale

    NARCIS (Netherlands)

    Dadun,; Peters, Ruth M. H.; Van Brakel, Wim H.; Lusli, Mimi; Damayanti, Rita; Irwanto, A.; Bunders- Aelen, J.G.F.

    Background: There is a need for comprehensive, valid and reliable instruments to assess leprosy-related stigma. This paper presents the process of the cross-cultural validation of an instrument in Cirebon District, Indonesia initiated by the Stigma Assessment and Reduction of Impact (SARI) project.

  8. Evaluation of the Primary Care in leprosy control: proposal of an instrument for users

    Directory of Open Access Journals (Sweden)

    Fernanda Moura Lanza

    2014-12-01

    Full Text Available Objective Developing an instrument to evaluate the performance of primary health care in the leprosy control actions, from the perspective of users and do the face and content validation. Method This is a methodological study carried out in four stages: development of instrument, face and content validation, pre-test, and analysis of test-retest reliability. Results The initial instrument submitted to the judgment of 15 experts was composed of 157 items. The face and content validation and pre-test of instrument were essential for the exclusion of items and adjustment of instrument to evaluate the object under study. In the analysis of test-retest reliability, the instrument proved to be reliable. Conclusion The instrument is considered adequate, but further studies are needed to test the psychometric properties.

  9. Usefulness Of Derivative Instruments In Emerging Markets: Turkish Experience

    OpenAIRE

    Cem Saatcioglu; Iskender Karagul; Ara G. Volkan

    2011-01-01

    This article presents an overview of derivative markets, definitions of derivative investment instruments, development of global derivative markets and the applicability of derivative markets in Turkey, given their economic value added to the Turkish economy. Readers will acquire insight into investing in various investment instruments and hedging against risk. Turkish derivative markets will be described, supportive statistical data will be presented, and readers will be introduced to the de...

  10. Instrument for liquids, amorphous and power diffraction

    International Nuclear Information System (INIS)

    Soper, A.K.

    1981-01-01

    A time-of-flight diffractometer, which has been built at the Los Alamos pulsed neutron source, is described. The concept of resolution focussing is discussed and the application of the instrument to liquid structure over a broad range of momentum transfers is presented

  11. Distributed Framework for Dynamic Telescope and Instrument Control

    Science.gov (United States)

    Ames, Troy J.; Case, Lynne

    2002-01-01

    Traditionally, instrument command and control systems have been developed specifically for a single instrument. Such solutions are frequently expensive and are inflexible to support the next instrument development effort. NASA Goddard Space Flight Center is developing an extensible framework, known as Instrument Remote Control (IRC) that applies to any kind of instrument that can be controlled by a computer. IRC combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML). A key aspect of the architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). IML is an XML dialect used to describe graphical user interfaces to control and monitor the instrument, command sets and command formats, data streams, communication mechanisms, and data processing algorithms. The IRC framework provides the ability to communicate to components anywhere on a network using the JXTA protocol for dynamic discovery of distributed components. JXTA (see httD://www.jxta.org,) is a generalized protocol that allows any devices connected by a network to communicate in a peer-to-peer manner. IRC uses JXTA to advertise a device's IML and discover devices of interest on the network. Devices can join or leave the network and thus join or leave the instrument control environment of IRC. Currently, several astronomical instruments are working with the IRC development team to develop custom components for IRC to control their instruments. These instruments include: High resolution Airborne Wideband Camera (HAWC), a first light instrument for the Stratospheric Observatory for Infrared Astronomy (SOFIA); Submillimeter And Far Infrared Experiment (SAFIRE), a Principal Investigator instrument for SOFIA; and Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE), a prototype of the SAFIRE instrument, used at the Caltech Submillimeter Observatory (CSO). Most recently, we have

  12. Division XII / Commission 41 / Working Group Historical Instruments

    Science.gov (United States)

    Pigatto, Luisa; Il-Seong, Nha; Hamel, Jürgen; Johnson, Kevin; Kochhar, Rajesh K.; Nakamura, Tsuko; Orchiston, Wayne; Pettersen, Bjørn R.; Schechner, Sara J.; Yunli, Shi

    The Historical Instruments Working Group (WG-HI) and Commission 41 started planning an interdisciplinary conference titled Astronomy and its instruments before and after Galileo since January 2007. This conference, as an IYA2009 initiative, aims “to highlight mankind's path toward an improved knowledge of the sky using mathematical and mechanical tools as well as monuments and buildings, giving rise, in doing so, to scientific astronomy”. Commission 46 and Commission 55 also support this conference, to be held on the Isle of San Servolo, Venice (Italy), 27 September 3 October 2009. As a fact of history, it was in Venice that Galileo was advised and got material (glass) to make his telescope, and in Venice he presented an working instrument to Venetian Doge in August 1609. The conference is co-sponsored by IAU as a Joint Symposium with the INAF Astronomical Observatory of Padova, Italy.

  13. Radiometric characterization of space instrumentation; Radiometrische Charakterisierung von Weltrauminstrumentierung

    Energy Technology Data Exchange (ETDEWEB)

    Gottwald, Alexander [Physikalisch-Technische Bundesanstalt (PTB), Berlin (Germany). Arbeitsgruppe ' UV- und VUV-Radiometrie' ; Klein, Roman; Krumrey, Michael; Mueller, Peter; Paustian, Wolfgang; Reichel, Thomas; Scholze, Frank; Thornagel, Reiner

    2014-09-15

    The calibration of detectors for space experiments using synchrotron radiation is described. Especially considered are spectrographs for the solar radiometry and instruments for X-ray astronomy. (HSI)

  14. Is there an association between temporomandibular disorders and playing a musical instrument? A review of literature

    NARCIS (Netherlands)

    Atallah, M.M.; Visscher, C.M.; van Selms, M.K.A.; Lobbezoo, F.

    2014-01-01

    Temporomandibular disorders (TMDs) have a multifactorial etiology. Among others, parafunctions and oral habits have been suggested as important initiating and perpetuating factors. Playing a musical instrument that loads the masticatory system, like wind instruments and the violin or viola, has been

  15. Argonne National Laboratory's thermal plume measurements: instruments and techniques

    International Nuclear Information System (INIS)

    Van Loon, L.S.; Frigo, A.A.; Paddock, R.A.

    1977-12-01

    Instrumentation and techniques were developed at Argonne National Laboratory for measuring the three-dimensional temperature structure of thermal plumes from power plants, along with the limnological, meteorological, and plant operating conditions affecting their behavior. The equipment and procedures were designed to provide field data for use in evaluating predictive models that describe thermal plume behavior, and over 100 sets of these data have been collected. The instrument systems and techniques employed in a typical thermal discharge survey are highly integrated. Continuous monitoring of ambient and plant conditions is coupled with plume mapping from a moving survey boat. The instantaneous location of the boat together with subsurface temperature measurements from a towed thermistor chain provide a quasisynoptic view of the plume structure. Real-time, onboard display of the boat path and vertical temperatures supply feedback to investigators for determining the extent and spatial resolution of measurements required. The unique design, reliability, accuracy, calibration, and historical development of the components of these integrated systems are described. Survey system interfaces with data handling and processing techniques are also explained. Special supportive studies to investigate plume dynamics, values of eddy diffusivities, time-temperature histories of water parcels in thermal plumes, and rapid changes in plume shape are also described along with instrumentation used

  16. Recent developments in nuclear instruments

    International Nuclear Information System (INIS)

    Vaidya, P.P.

    2004-01-01

    Full text : Nuclear Instrumentation is a field of vital importance for DAE. It has important applications in many areas of interest such as Reactor Monitoring and control, Accelerator based research, Laser and nuclear physics experiments, Health and environmental monitoring, Astrophysics experiments etc. It is a specialized field involving expertise in detection of radioactivity down to the level of few events per minute as well as processing and analysis of signals which can be as small as few hundred micro volts embedded in noise. Some applications involve digitizing and processing these signals with 0.001% accuracy and timing accuracies of a fraction of nano sec. Rapid developments in semiconductor related technologies have influenced the field of nuclear instrumentation. Development of FPGA's and ASIC's have made it possible to develop miniaturized smart and portable instruments for field applications. Advancements in field of computers, communications and various field buses have been successfully utilized for smart, portable and DSP based instrumentation. Smart sensor with detector and front-end electronics on a single silicon chip is now a reality. These instruments are also made intelligent by addition of fuzzy logic, artificial neural networks and expert systems. Electronics Division of BARC has made significant contribution to the field of nuclear instrumentation to achieve self-reliance in this area. This has also led to development of several new methods, which have been published in international journals and appreciated worldwide. As a step towards achieving complete self-reliance a programme for development of FPGA's, HMC's and ASIC's has been undertaken and is being followed with special emphasis. This also includes development of detector and front- end electronics on a single chip. This talk brings out details of these developments and describes the 'state of art' work done in India

  17. Instrumentation for environmental monitoring. Volume 1. Radiation. Second Edition

    International Nuclear Information System (INIS)

    Budnitz, R.J.; Nero, A.V.; Murphy, D.J.; Graven, R.

    1983-01-01

    This volume describes ionizing radiation and the instruments used for measurement. Units, sources, and effects of radiation are introduced, basic detection methods discussed, and measurement of alpha, beta, gamma and x-radiation described. Sources of anthropogenic radiation are discussed in detail: nuclear power plants, spent-fuel processing, and uranium mining and milling

  18. Brookhaven National Laboratory meteorological services instrument calibration plan and procedures

    Energy Technology Data Exchange (ETDEWEB)

    Heiser, John [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2013-02-16

    This document describes the Meteorological Services (Met Services) Calibration and Maintenance Schedule and Procedures, The purpose is to establish the frequency and mechanism for the calibration and maintenance of the network of meteorological instrumentation operated by Met Services. The goal is to maintain the network in a manner that will result in accurate, precise and reliable readings from the instrumentation.

  19. Instrument employing a charge flow transistor

    International Nuclear Information System (INIS)

    1981-01-01

    The invention concerns instruments employing charge-flow transistors that operate to sense a property in the surrounding environment. It is based on a particular sensor principle, thin-film conduction. The instruments described include a charge-flow transistor with semiconductor substrate, a source region, a drain region, a gate insulator, and a gapped electrode structure with a thin-film sensor material in the gap. The sensor material has an electrical conductance that is sensitive to a property of the ambient environment and has a surface conductance that differs substantially from its bulk conductance. The main object is to provide a low-cost instrument for early-warning fire-detection devices: in this case the property detected would be the products of combustion. Other properties that can be sensed include gases or vapors, free radicals, vapor electromagnetic radiation, subatomic particles, atomic or molecular beams, changes in ambient pressure or temperature, the chemical composition and the electrochemical potential of a solution. (U.K.)

  20. Instrument employing a charge flow transistor

    Energy Technology Data Exchange (ETDEWEB)

    1981-03-11

    The invention concerns instruments employing charge-flow transistors that operate to sense a property in the surrounding environment. It is based on a particular sensor principle, thin-film conduction. The instruments described include a charge-flow transistor with semiconductor substrate, a source region, a drain region, a gate insulator, and a gapped electrode structure with a thin-film sensor material in the gap. The sensor material has an electrical conductance that is sensitive to a property of the ambient environment and has a surface conductance that differs substantially from its bulk conductance. The main object is to provide a low-cost instrument for early-warning fire-detection devices: in this case the property detected would be the products of combustion. Other properties that can be sensed include gases or vapors, free radicals, vapor electromagnetic radiation, subatomic particles, atomic or molecular beams, changes in ambient pressure or temperature, the chemical composition and the electrochemical potential of a solution.

  1. Taking spiritual history in clinical practice: a systematic review of instruments.

    Science.gov (United States)

    Lucchetti, Giancarlo; Bassi, Rodrigo M; Lucchetti, Alessandra L Granero

    2013-01-01

    To facilitate the addressing of spirituality in clinical practice, several authors have created instruments for obtaining a spiritual history. However, in only a few studies have authors compared these instruments. The aim of this study was to compare the most commonly used instruments for taking a spiritual history in a clinical setting. A systematic review of spiritual history assessment was conducted in five stages: identification of instruments used in the literature (databases searching); relevant articles from title and initial abstract review; exclusion and Inclusion criteria; full text retrieval and final analysis of each instrument. A total of 2,641 articles were retrieved and after the analysis, 25 instruments were included. The authors independently evaluated each instrument on 16 different aspects. The instruments with the greatest scores in the final analysis were FICA, SPIRITual History, FAITH, HOPE, and the Royal College of Psychiatrists. Concerning all 25 instruments, 20 of 25 inquire about the influence of spirituality on a person's life and 17 address religious coping. Nevertheless, only four inquire about medical practices not allowed, six deal with terminal events, nine have mnemonics to facilitate their use, and five were validated. FICA, SPIRITual History, FAITH, HOPE, and Royal College of Psychiatrists scored higher in our analysis. The use of each instrument must be individualized, according to the professional reality, time available, patient profile, and settings. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Development of an alpha scattering instrument for heavy element detection in surface materials. Final report

    International Nuclear Information System (INIS)

    Turkevich, A.L.; Economou, T.; Blume, E.; Anderson, W.

    1974-12-01

    The development and characteristics of a portable instrument for detecting and measuring the amounts of lead in painted surfaces are discussed. The instrument is based on the ones used with the alpha scattering experiment on the Surveyor lunar missions. The principles underlying the instrument are described. It is stated that the performance tests of the instrument were satisfactory. (auth)

  3. An automated calibration laboratory for flight research instrumentation: Requirements and a proposed design approach

    Science.gov (United States)

    Oneill-Rood, Nora; Glover, Richard D.

    1990-01-01

    NASA's Dryden Flight Research Facility (Ames-Dryden), operates a diverse fleet of research aircraft which are heavily instrumented to provide both real time data for in-flight monitoring and recorded data for postflight analysis. Ames-Dryden's existing automated calibration (AUTOCAL) laboratory is a computerized facility which tests aircraft sensors to certify accuracy for anticipated harsh flight environments. Recently, a major AUTOCAL lab upgrade was initiated; the goal of this modernization is to enhance productivity and improve configuration management for both software and test data. The new system will have multiple testing stations employing distributed processing linked by a local area network to a centralized database. The baseline requirements for the new AUTOCAL lab and the design approach being taken for its mechanization are described.

  4. Informal caregiving in COPD: A systematic review of instruments and their measurement properties.

    Science.gov (United States)

    Cruz, Joana; Marques, Alda; Machado, Ana; O'Hoski, Sachi; Goldstein, Roger; Brooks, Dina

    2017-07-01

    Increasing symptoms and activity restriction associated with COPD progression greatly impact on the lives of their informal caregivers, who play a vital role in maintaining their health. An understanding of this impact is important for clinicians to support caregivers and maintain a viable patient environment at home. This systematic review aimed to identify the instruments commonly used to assess informal caregiving in COPD and describe their measurement properties in this population. Searches were conducted in PubMed, Scopus, Web of Science, CINAHL and PsycINFO and in references of key articles, until November 2016 (PROSPERO: CRD42016041401). Instruments used to assess the impact of COPD on caregivers were identified and their properties described. Quality of studies was rated using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. Quality of the measurement properties of instruments was rated as 'positive', 'negative' or 'indeterminate'. Patients cared for, had moderate to very severe COPD and the sample of caregivers ranged from 24 to 406. Thirty-five instruments were used in fifty studies to assess caregivers' psychological status and mood (9 instruments), burden/distress (12 instruments), quality of life (5 instruments) or other (9 instruments). Eighteen studies assessed the measurement properties of 21 instruments, most commonly hypothesis testing (known validity) and internal consistency. Study quality varied from 'poor' to 'fair' and with many properties rated as 'indeterminate'. Although several instruments have been used to assess the impact of COPD on caregivers, an increased understanding of their properties is needed before their widespread implementation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Real-time instrument-failure detection in the LOFT pressurizer using functional redundancy

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1982-07-01

    The functional redundancy approach to detecting instrument failures in a pressurized water reactor (PWR) pressurizer is described and evaluated. This real-time method uses a bank of Kalman filters (one for each instrument) to generate optimal estimates of the pressurizer state. By performing consistency checks between the output of each filter, failed instruments can be identified. Simulation results and actual pressurizer data are used to demonstrate the capabilities of the technique

  6. The Appetitive Aggression Scale—development of an instrument for the assessment of human's attraction to violence.

    Directory of Open Access Journals (Sweden)

    Roland Weierstall

    2011-11-01

    Full Text Available Background : Several instruments, notably Buss and Perry's Aggression Questionnaire, have been developed for the assessment of aggressive behavior. However, in these instruments, the focus has been on reactive rather than instrumental forms of aggression, even though men in particular may find aggressive behavior attractive. A questionnaire or structured interview for the systematic assessment of the attraction to violence is not yet available. Objective : We, therefore, developed a freely available short form for the assessment of a person's attraction to violent and planned forms of aggression based on reports of former combatants on the attraction to violence and the characteristics of instrumental aggression described in the literature. Method : The Appetitive Aggression Scale (AAS was administered to nine samples drawn from different populations, with a total of 1,632 former combatants and participants from war-affected regions (1,193 male and 439 female respondents. Results : From the initial set of 31 items, a selection of 15 items was extracted to improve the scale's psychometric properties and assess the construct of appetitive aggression validly with respect to content. Cronbach's Alpha coefficient of 0.85 was appropriate. All items loaded significantly on a single factor accounting for 32% of the total variance. Further analysis revealed that the scale measures a specific construct that can be distinguished from other concepts of human aggression. Conclusions : With the AAS, we present an easily administrable tool for the assessment of the attraction to violence.

  7. Eliminating Survivor Bias in Two-stage Instrumental Variable Estimators.

    Science.gov (United States)

    Vansteelandt, Stijn; Walter, Stefan; Tchetgen Tchetgen, Eric

    2018-07-01

    Mendelian randomization studies commonly focus on elderly populations. This makes the instrumental variables analysis of such studies sensitive to survivor bias, a type of selection bias. A particular concern is that the instrumental variable conditions, even when valid for the source population, may be violated for the selective population of individuals who survive the onset of the study. This is potentially very damaging because Mendelian randomization studies are known to be sensitive to bias due to even minor violations of the instrumental variable conditions. Interestingly, the instrumental variable conditions continue to hold within certain risk sets of individuals who are still alive at a given age when the instrument and unmeasured confounders exert additive effects on the exposure, and moreover, the exposure and unmeasured confounders exert additive effects on the hazard of death. In this article, we will exploit this property to derive a two-stage instrumental variable estimator for the effect of exposure on mortality, which is insulated against the above described selection bias under these additivity assumptions.

  8. The Vector Electric Field Instrument on the C/NOFS Satellite

    Science.gov (United States)

    Pfaff, R.; Kujawski, J.; Uribe, P.; Bromund, K.; Fourre, R.; Acuna, M.; Le, G.; Farrell, W.; Holzworth, R.; McCarthy, M.; hide

    2008-01-01

    We provide an overview of the Vector Electric Field Instrument (VEFI) on the Air Force Communication/Navigation Outage Forecasting System (C/NOFS) satellite, a mission designed to understand, model, and forecast the presence of equatorial ionospheric irregularities. VEFI is a NASA GSFC instrument designed 1) to investigate the role of the ambient electric fields in initiating nighttime ionospheric density depletions and turbulence; 2) to determine the electric fields associated with abrupt, large amplitude, density depletions and 3) to quantify the spectrum of the wave electric fields and plasma densities (irregularities) associated with density depletions or Equatorial Spread-F. The VEFI instrument includes a vector electric field double probe detector, a Langmuir trigger probe, a flux gate magnetometer, a lightning detector and associated electronics. The heart of the instrument is the set of double probe detectors designed to measure DC and AC electric fields using 6 identical, mutually orthogonal, deployable 9.5 m booms tipped with 10 cm diameter spheres containing embedded preamplifiers. A description of the instrument and its sensors will be presented. If available, representative measurements will be provided.

  9. Experience with the instrumentation tests in large sodium test facilities

    International Nuclear Information System (INIS)

    Lauhoff, Th.; Ruppert, E.; Stehle, H.; Vinzens, K.

    1976-01-01

    A facility is described for fast breeder core components (AKB) to test specially instrumented fuel dummies and blanket elements, and also absorber elements under simulated normal and extreme reactor conditions. In addition to endurance testing of a special sodium and high temperature sub-assembly, instrumentation is provided to investigate thermohydraulic and vibrational behaviour of core elements. During tests of > 3000 h at temperatures above 820 K the main sub-assembly characteristics, e.g. pressure drop, leakage flow, vibration and noise spectra can be reproduced. The use of eddy current flow meters, strain gauges, magnetostrictive noise sensors, pressure transducers, thermocouples, and acoustic surveillance devices, are described. (U.K.)

  10. 24 CFR 213.266 - Initial insurance endorsement.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Initial insurance endorsement. 213... insurance endorsement. The Commissioner shall indicate his insurance of the mortgage or supplementary loan by endorsing the original credit instrument and identifying the section of the Act and the...

  11. Current status of some neutron instruments in Serpong

    Energy Technology Data Exchange (ETDEWEB)

    Ikram, A; Hardi, T; Maulana, A [Neutron Scattering Lab., Materials Science Research Center, BATAN-Serpong, Jakarta (Indonesia)

    1998-10-01

    Performances of the Small Angle Neutron Scattering Spectrometer, the High Resolution Small Angle Neutron Scattering Spectrometer and the High Resolution Neutron Powder Diffractometer in the last full one year are presented as well as problems, difficulties and limitations faced by each instrument. Efforts that have been done to overcome those shortcomings are also mentioned. Proposed collaboration in order to bring those instruments back to a state that can perform scientifically acceptable is described to a level that can be agreed in this workshop. (author)

  12. Remote sensing technology research and instrumentation platform design

    Science.gov (United States)

    1992-01-01

    An instrumented pallet concept and definition of an aircraft with performance and payload capability to meet NASA's airborne turbulent flux measurement needs for advanced multiple global climate research and field experiments is presented. The report addresses airborne measurement requirements for general circulation model sub-scale parameterization research, specifies instrumentation capable of making these measurements, and describes a preliminary support pallet design. Also, a review of aircraft types and a recommendation of a manned and an unmanned aircraft capable of meeting flux parameterization research needs is given.

  13. First Experience with the LHC Cryogenic Instrumentation

    CERN Document Server

    Vauthier, N; Balle, Ch; Casas-Cubillos, J; Ciechanowski, M; Fernandez-Penacoba, G; Fortescue-Beck, E; Gomes, P; Jeanmonod, N; Lopez-Lorente, A; Suraci, A

    2008-01-01

    The LHC under commissioning at CERN will be the world's largest superconducting accelerator and therefore makes extensive use of cryogenic instruments. These instruments are installed in the tunnel and therefore have to withstand the LHC environment that imposes radiation-tolerant design and construction. Most of the instruments require individual calibration; some of them exhibit several variants as concerns measuring span; all relevant data are therefore stored in an Oracle® database. Those data are used for the various quality assurance procedures defined for installation and commissioning, as well as for generating tables used by the control system to configure automatically the input/output channels. This paper describes the commissioning of the sensors and the corresponding electronics, the first measurement results during the cool-down of one machine sector; it discusses the different encountered problems and their corresponding solutions.

  14. Field measurements and interpretation of TMI-2 instrumentation: IC-10-dPT

    International Nuclear Information System (INIS)

    Jones, J.E.; Smith, J.T.; Mathis, M.V.

    1982-01-01

    This report describes the measurements and results of the Control Rod Drive Bypass Flow IC-10-dPT. This instrument consists of a Bailey Type BY Process Computer Transmitter connected to a readout module by approximately 500 feet of cable through a penetration junction and an instrument mounting junction. The status of this instrument is uncertain, but it was producing a reasonable output reading of zero flow which could indicate it had not failed. As a result, measurements on this instrument were designed to determine if it were properly functioning

  15. Instrumentation and Control Life Cycle Management Plan Methodology. Volume 1, Manual: Final report

    International Nuclear Information System (INIS)

    Quick, D.S.; Murray, S.; Florio, F.; Bliss, M.J.

    1995-08-01

    This methodology manual describes how to develop a Life Cycle Management Plan (LCMP). An LCMP is a long-term strategic plan that can be developed for a nuclear power plant to cost-effectively maintain and upgrade its aging or obsolete Instrumentation and Control (I ampersand C) systems. An LCMP defines the utility's mission and objectives in regards to long range I ampersand C planning, as well as the plant's present configuration (I ampersand C systems, networks, man machine interfaces, etc.), its desired future I ampersand C systems, a long term I ampersand C maintenance strategy, and initial upgrade priorities and schedules to cost-effectively implement system upgrades. This manual is accompanied by a workbook (EPRI TR-105555-V2) which contains various worksheets, outlines, and generic interview questions that aid in the LCNW development process

  16. Identification Of Financial Instruments – Important Step in Building Portfolios

    Directory of Open Access Journals (Sweden)

    Mădălina-Gabriela Anghel

    2013-10-01

    Full Text Available Construction of any portfolio is initially identifying financial instruments to be traded, and the timing for entering the capital market (ie the optimal timing of trading . This is the stage in which the market analysis is made in order to collect the necessary information in making investment decision. In this regard it is recommended that investment activity should be based on a thorough evaluation of both the individual performance of the instruments to be purchased and the overall development of the capital market on which the investment is to be made.

  17. CAMAC instrumentation system: introduction and general description

    International Nuclear Information System (INIS)

    Costrell, L.

    1976-01-01

    The CAMAC instrumentation system is described in a general way in this introductory paper which is followed by papers that discuss the system in greater detail. This paper is an updated version of the introductory paper that appeared in the April 1973 IEEE Transactions on Nuclear Science

  18. Instrumentation for chemical and radiochemical monitoring in nuclear power plants

    International Nuclear Information System (INIS)

    Nordmann, F.; Ballard, G.

    2009-01-01

    This article details the instrumentation implemented in French nuclear power plants for the monitoring of chemical and radiochemical effluents with the aim of limiting their environmental impact. It describes the controls performed with chemical automata for the search for drifts, anomalies or pollution in a given circuit. The operation principles of the different types of chemical automata are explained as well as the manual controls performed on samples manually collected. Content: 1 - general considerations; 2 - objectives of the chemical monitoring: usefulness of continuous monitoring with automata, transmission to control rooms and related actions, redundancy of automata; 3 - instrumentation and explanations for the main circuits: principle of chemical automata monitoring, instrumentation of the main primary circuit, instrumentation of the main secondary circuit, instrumentation of the tertiary circuit, preparation of water makeup (demineralized water), other loops, instrumentation for effluents and environment monitoring, measurement principles of chemical automata, control and maintenance of chemical automata; 4 - manual controls after sampling; 5 - radiochemical monitoring: automatized radiochemical measurements, manual radiochemical measurements; 6 - conclusion

  19. Systematizing the Instruments of Trade Wars and of Concealed Protectionism

    Directory of Open Access Journals (Sweden)

    Serpukhov Maksym Yu.

    2017-11-01

    Full Text Available The article is concerned with the problems of trade wars and hidden protectionism in the process of implementing international trade. The main purpose of the research is systematization of trade barriers and instruments used in the trade wars between countries. The basic instruments of trade wars have been analyzed, a list of the key instruments used in the trade wars between countries has been defined, and also the possible influence of these instruments has been described. The statistical analysis has resulted in identifying the main trade barriers and the most popular sectors of the economy in which protectionism instruments are applied. The authors have also defined the main interventions applied by different world countries in relation to Ukrainian products and groups of Ukrainian goods to which the most restrictions by the world countries are applied. The conclusions on counteraction and adaptation to the most popular instruments of protectionism in the process of activation of the export activity of country have been generalized.

  20. Instrumentation for two-phase flow measurements in code verification experiments

    International Nuclear Information System (INIS)

    Fincke, J.R.; Anderson, J.L.; Arave, A.E.; Deason, V.A.; Lassahn, G.D.; Goodrich, L.D.; Colson, J.B.; Fickas, E.T.

    1981-01-01

    The development of instrumentation and techniques for the measurement of mass flow rate in two-phase flows conducted at the Idaho National Engineering Laboratory during the past year is briefly described. Instruments discussed are the modular drag-disc turbine transducer, the gamma densitometers, the ultrasonic densitometer, Pitot tubes, and full-flow drag screens. Steady state air-water and transient steam-water data are presented

  1. New instrumentation for the IPR-R1 reactor of CDTN

    International Nuclear Information System (INIS)

    Carvalho, P.V.R. de.

    1992-01-01

    The Nuclear Engineering Institute reactor instrumentation area has developed systems and equipment for reactor operation and safety. In such way, the new I and C for IEN Argonauta reactor and the nuclear instrumentation for IPEN critical facility were built. This paper describes our real work, the new I and C systems for IPR-R1, a Triga type reactor, located at CDTN (Belo Horizonte - MG). (author)

  2. Radiation protection instrumentation for personnel dosimetry, area and environmental monitoring

    International Nuclear Information System (INIS)

    Jones, A.R.

    1978-04-01

    Several kinds of personal dosimeter exist and their performance is reviewed in the light of requirements for an ideal instrument. The requirements of portable instruments are reviewed and the extent to which they are met in one example is described. Where permitted environmental doses are larger than the fluctuations in natural backgrounds, certain types of thermoluminescent dosimeters provide a cheaper and reliable alternative measuring system

  3. Zakat as an Instrument of Eradicating Poverty (Indonesian Case

    Directory of Open Access Journals (Sweden)

    Mohamad Anton Athoillah

    2014-06-01

    Full Text Available This paper describes more clearly about the charity as an instrument of poverty alleviation. Said to be more pronounced because zakat is not only described from the aspect of Islamic law, but also from the aspect of Islamic Economics. Starting from the idea of a content analysis of two professors of Economic Development, Prahalad and Yuyun Wirasasmita, this paper reveals the fundamental aspects of the causes of poverty, namely culture, alienation and exploitation. In this paper, the charity manages to pack in a comprehensive manner to a complementary instrument, whether Islamic law, and even Islamic Economics. Among the novelties in this paper is a substantive interpretation of zakat which is connected with the theory of economic development, compared with tax and economic-mathematical analysis to find a charity to further its position in the study of economics. As for other things that were outlined in this paper is the normative aspects of zakat, as where made explicit, as an instrument of poverty alleviation for various sectors, as seen from its usability goals.

  4. Development of network communication function for digitalized neutron flux monitoring instrument

    International Nuclear Information System (INIS)

    Li Kai; Zhang Liangju; Chen Xiaojun; Li Baoxiang

    2002-01-01

    It is essential for a digitalized Neutron Flux Monitoring Instrument to communicate with other parts of Instrumentation and Control System in a network environment, and it is fairly different from the case of traditional analogue nuclear instrumentation. How to satisfy all the requirements of different network structure and communication protocol, which might be adopted in different target nuclear power plant, is a key issue in the design and development of a digitalized neutron flux monitoring instrument. The author describes the overall communication scheme, mainly discusses the design idea and the requirements of the communication interfaces and the implementation of the RS-485 interface as an example of the digitalized neutron flux monitoring instrument, which is under development in the institute

  5. Balances instruments, manufacturers, history

    CERN Document Server

    Robens, Erich; Kiefer, Susanne

    2014-01-01

    The book deals mainly with direct mass determination by means of a conventional balances. It covers the history of the balance from the beginnings in Egypt earlier than 3000 BC to recent developments. All balance types are described with emphasis on scientific balances. Methods of indirect mass determination, which are applied to very light objects like molecules and the basic particles of matter and celestial bodies, are included.  As additional guidance, today’s manufacturers are listed and the profile of important companies is reviewed. Several hundred photographs, reproductions and drawings show instruments and their uses. This book includes commercial weighing instruments for merchandise and raw materials in workshops as well as symbolic weighing in the ancient Egyptian’s ceremony of ‘Weighing of the Heart’, the Greek fate balance, the Roman  Justitia, Juno Moneta and Middle Ages scenes of the Last Judgement with Jesus or St. Michael and of modern balances. The photographs are selected from the...

  6. Instrument Remote Control via the Astronomical Instrument Markup Language

    Science.gov (United States)

    Sall, Ken; Ames, Troy; Warsaw, Craig; Koons, Lisa; Shafer, Richard

    1998-01-01

    The Instrument Remote Control (IRC) project ongoing at NASA's Goddard Space Flight Center's (GSFC) Information Systems Center (ISC) supports NASA's mission by defining an adaptive intranet-based framework that provides robust interactive and distributed control and monitoring of remote instruments. An astronomical IRC architecture that combines the platform-independent processing capabilities of Java with the power of Extensible Markup Language (XML) to express hierarchical data in an equally platform-independent, as well as human readable manner, has been developed. This architecture is implemented using a variety of XML support tools and Application Programming Interfaces (API) written in Java. IRC will enable trusted astronomers from around the world to easily access infrared instruments (e.g., telescopes, cameras, and spectrometers) located in remote, inhospitable environments, such as the South Pole, a high Chilean mountaintop, or an airborne observatory aboard a Boeing 747. Using IRC's frameworks, an astronomer or other scientist can easily define the type of onboard instrument, control the instrument remotely, and return monitoring data all through the intranet. The Astronomical Instrument Markup Language (AIML) is the first implementation of the more general Instrument Markup Language (IML). The key aspects of our approach to instrument description and control applies to many domains, from medical instruments to machine assembly lines. The concepts behind AIML apply equally well to the description and control of instruments in general. IRC enables us to apply our techniques to several instruments, preferably from different observatories.

  7. Design, validation, and use of an evaluation instrument for monitoring systemic reform

    Science.gov (United States)

    Scantlebury, Kathryn; Boone, William; Butler Kahle, Jane; Fraser, Barry J.

    2001-08-01

    Over the past decade, state and national policymakers have promoted systemic reform as a way to achieve high-quality science education for all students. However, few instruments are available to measure changes in key dimensions relevant to systemic reform such as teaching practices, student attitudes, or home and peer support. Furthermore, Rasch methods of analysis are needed to permit valid comparison of different cohorts of students during different years of a reform effort. This article describes the design, development, validation, and use of an instrument that measures student attitudes and several environment dimensions (standards-based teaching, home support, and peer support) using a three-step process that incorporated expert opinion, factor analysis, and item response theory. The instrument was validated with over 8,000 science and mathematics students, taught by more than 1,000 teachers in over 200 schools as part of a comprehensive assessment of the effectiveness of Ohio's systemic reform initiative. When the new four-factor, 20-item questionnaire was used to explore the relative influence of the class, home, and peer environment on student achievement and attitudes, findings were remarkably consistent across 3 years and different units and methods of analysis. All three environments accounted for unique variance in student attitudes, but only the environment of the class accounted for unique variance in student achievement. However, the class environment (standards-based teaching practices) was the strongest independent predictor of both achievement and attitude, and appreciable amounts of the total variance in attitudes were common to the three environments.

  8. A proposal for assessing study quality: Biomonitoring, Environmental Epidemiology, and Short-lived Chemicals (BEES-C) instrument

    Science.gov (United States)

    LaKind, Judy S.; Sobus, Jon R.; Goodman, Michael; Barr, Dana Boyd; Fürst, Peter; Albertini, Richard J.; Arbuckle, Tye E.; Schoeters, Greet; Tan, Yu-Mei; Teeguarden, Justin; Tornero-Velez, Rogelio; Weisel, Clifford P.

    2015-01-01

    The quality of exposure assessment is a major determinant of the overall quality of any environmental epidemiology study. The use of biomonitoring as a tool for assessing exposure to ubiquitous chemicals with short physiologic half-lives began relatively recently. These chemicals present several challenges, including their presence in analytical laboratories and sampling equipment, difficulty in establishing temporal order in cross-sectional studies, short- and long-term variability in exposures and biomarker concentrations, and a paucity of information on the number of measurements required for proper exposure classification. To date, the scientific community has not developed a set of systematic guidelines for designing, implementing and interpreting studies of short-lived chemicals that use biomonitoring as the exposure metric or for evaluating the quality of this type of research for WOE assessments or for peer review of grants or publications. We describe key issues that affect epidemiology studies using biomonitoring data on short-lived chemicals and propose a systematic instrument – the Biomonitoring, Environmental Epidemiology, and Short-lived Chemicals (BEES-C) instrument – for evaluating the quality of research proposals and studies that incorporate biomonitoring data on short-lived chemicals. Quality criteria for three areas considered fundamental to the evaluation of epidemiology studies that include biological measurements of short-lived chemicals are described: 1) biomarker selection and measurement, 2) study design and execution, and 3) general epidemiological study design considerations. We recognize that the development of an evaluative tool such as BEES-C is neither simple nor non-controversial. We hope and anticipate that the instrument will initiate further discussion/debate on this topic. PMID:25137624

  9. An Optional Instrument for European Insurance Contract Law

    Directory of Open Access Journals (Sweden)

    Helmut Heiss

    2010-08-01

    Full Text Available The Principles of European Insurance Contract Law, also referred tousing the acronym PEICL, were published in September 2009. They are the result of ten years of academic work undertaken by the"Restatement of European Insurance Contract Law" Project Group. In the time since its establishment in 1999, the project has been transformed from being a stand-alone project to a part of the CoPECL (Common Principles of European Insurance Contract Law network, drafting a specific part of the Common Frame of Reference. Having continually worked under the guiding principle that "the law of insurance [in Europe] must be one," it now represents a serious option for providing Europe with a single legal framework for insurance contracts.Despite the European Council's proclamations that the Common Frame of Reference will remain a non-binding instrument, the implementation of one or more optional instruments in the future does not appear to beimprobable considering recent developments. The possibility of anoptional instrument has been expressed more than once by the European Commission in its Action Plan and Communication on European Contract Law. Other indications in favour of an optional instrument include the European Parliament's repeated references to the Common Frame of Reference as providing, at the very least, a model for a futureoptional instrument, as well as the EESC's earlier proposal of anoptional instrument as an alternative to standardising insurancecontract law. The preparation by the EESC of another (own-initiative opinion on European contract law is underway, and its presentation is anticipated in 2010. Hence, the optional instrument is evidently the subject of serious political deliberation. Using Article 1:102, the Principles of European Insurance Contract Law represent a prototype for such an instrument.

  10. An Optional Instrument for European Insurance Contract Law

    Directory of Open Access Journals (Sweden)

    Mandeep Lakhan

    2010-08-01

    Full Text Available The Principles of European Insurance Contract Law, also referred tousing the acronym PEICL, were published in September 2009. They are the result of ten years of academic work undertaken by the"Restatement of European Insurance Contract Law" Project Group. In the time since its establishment in 1999, the project has been transformed from being a stand-alone project to a part of the CoPECL (Common Principles of European Insurance Contract Law network, drafting a specific part of the Common Frame of Reference. Having continually worked under the guiding principle that "the law of insurance [in Europe] must be one," it now represents a serious option for providing Europe with a single legal framework for insurance contracts. Despite the European Council's proclamations that the Common Frame of Reference will remain a non-binding instrument, the implementation of one or more optional instruments in the future does not appear to beimprobable considering recent developments. The possibility of anoptional instrument has been expressed more than once by the European Commission in its Action Plan and Communication on European Contract Law. Other indications in favour of an optional instrument include the European Parliament's repeated references to the Common Frame of Reference as providing, at the very least, a model for a futureoptional instrument, as well as the EESC's earlier proposal of anoptional instrument as an alternative to standardising insurancecontract law. The preparation by the EESC of another (own-initiative opinion on European contract law is underway, and its presentation is anticipated in 2010. Hence, the optional instrument is evidently the subject of serious political deliberation. Using Article 1:102, the Principles of European Insurance Contract Law represent a prototype for such an instrument.

  11. The Optical Instrumentation of the ATLAS Tile Calorimeter

    CERN Document Server

    Abdallah, J; Alexa, C; Alves, R; Amaral, P; Ananiev, A; Anderson, K; Andresen, X; Antonaki, A; Batusov, V; Bednar, P; Bergeaas, E; Biscarat, C; Blanch, O; Blanchot, G; Bohm, C; Boldea, V; Bosi, F; Bosman, M; Bromberg, C; Budagov, Yu A; Calvet, D; Cardeira, C; Carli, T; Carvalho, J; Cascella, M; Castillo, M V; Costelo, J; Cavalli-Sforza, M; Cavasinni, V; Cerqueira, A S; Clément, C; Cobal, M; Cogswell, F; Constantinescu, S; Costanzo, D; Da Silva, P; David, M; Davidek, T; Dawson, J; De, K; Del Prete, T; Diakov, E; Di Girolamo, B; Dita, S; Dolejsi, J; Dolezal, Z; Dotti, A; Downing, R; Drake, G; Efthymiopoulos, I; Errede, D; Errede, S; Farbin, A; Fassouliotis, D; Feng, E; Fenyuk, A; Ferdi, C; Ferreira, B C; Ferrer, A; Flaminio, V; Flix, J; Francavilla, P; Fullana, E; Garde, V; Gellerstedt, K; Giakoumopoulou, V; Giangiobbe, V; Gildemeister, O; Gilewsky, V; Giokaris, N; Gollub, N; Gomes, A; González, V; Gouveia, J; Grenier, P; Gris, P; Guarino, V; Guicheney, C; Sen-Gupta, A; Hakobyan, H; Haney, M; Hellman, S; Henriques, A; Higón, E; Hill, N; Holmgren, S; Hruska, I; Hurwitz, M; Huston, J; Jen-La Plante, I; Jon-And, K; Junk, T; Karyukhin, A; Khubua, J; Klereborn, J; Konsnantinov, V; Kopikov, S; Korolkov, I; Krivkova, P; Kulchitsky, Y; Kurochkin, Yu; Kuzhir, P; Lapin, V; Le Compte, T; Lefèvre, R; Leitner, R; Li, J; Liablin, M; Lokajícek, M; Lomakin, Y; Lourtie, P; Lovas, L; Lupi, A; Maidantchik, C; Maio, A; Maliukov, S; Manousakis, A; Marques, C; Marroquim, F; Martin, F; Mazzoni, E; Merritt, F S; Myagkov, A; Miller, R; Minashvili, I; Miralles, L; Montarou, G; Némécek, S; Nessi, M; Nikitine, I; Nodulman, L; Norniella, O; Onofre, A; Oreglia, M; Palan, B; Pallin, D; Pantea, D; Pereira, A; Pilcher, J E; Pina, J; Pinhão, J; Pod, E; Podlyski, F; Portell, X; Poveda, J; Pribyl, L; Price, L E; Proudfoot, J; Ramalho, M; Ramstedt, M; Raposeiro, L; Reis, J; Richards, R; Roda, C; Romanov, V; Rosnet, R; Roy, P; Ruiz, A; Rumiantsau, V; Russakovich, N; Sada Costa, J; Salto, O; Salvachúa, B; Sanchis, E; Sanders, H; Santoni, C; Santos, J; Saraiva, J G; Sarri, F; Says, L P; Schlager, G; Schlereth, J L; Seixas, J M; Selldén, B; Shalanda, N; Shevtsov, P; Shochet, M; Silva, J; Simaitis, V; Simonyan, M; Sisakian, A; Sjölin, J; Solans, C; Solodkov, A; Solovyanov, O; Sosebee, M; Spanó, F; Speckmeyer, P; Stanek, R; Starchenko, E; Starovoitov, P; Suk, M; Sykora, I; Tang, F; Tas, P; Teuscher, R; Tischenko, M; Tokar, S; Topilin, N; Torres, J; Underwood, D; Usai, G; Valero, A; Valkár, S; Valls, J A; Vartapetian, A; Vazielle, F; Vellidis, C; Ventura, F; Vichou, I; Vivarelli, I; Volpi, M; White, A; Zaitsev, A; Zaytsev, Yu; Zenin, A; Zenis, T; Zenonos, Z; Zenz, S; Zilka, B

    2013-01-01

    The purpose of this Note is to describe the optical assembly procedure called here Optical Instrumentation and the quality tests conducted on the assembled units. Altogether, 65 Barrel (or LB) modules were constructed - including one spare - together with 129 Extended Barrel (EB) modules (including one spare). The LB modules were mechanically assembled at JINR (Dubna, Russia) and transported to CERN, where the optical instrumentation was performed with personnel contributed by several Institutes. The modules composing one of the two Extended Barrels (known as EBA) were mechanically assembled in the USA, and instrumented in two US locations (ANL, U. of Michigan), while the modules of the other Extended barrel (EBC) were assembled in Spain and instrumented at IFAE (Barcelona). Each of the EB modules includes a subassembly known as ITC that contributes to the hermeticity of the calorimeter; all ITCs were assembled at UTA (Texas), and mounted onto the module mechanical structures at the EB mechanical assembly loc...

  12. General and preliminary thermohydraulic, hydrogen and aerosol instrumentation plan for the Phebus Fp-project

    International Nuclear Information System (INIS)

    Hampel, G.; Poss, G.; Frohlich, H.K.

    1989-10-01

    The objective of the project was to draw up an instrumentation plan for the French core melting programme PHEBUS FP. This instrumentation plan essentially was to include proven and reliable instruments for recording various thermohydraulic, aerosol and hydrogen phenomena. The candidate measuring methods, which are known mainly from reactor safety programmes, have been described and examined for their usefulness in PHEBUS. Each method and instrument has been described in detail under various aspects such as measuring principle, measuring range, technical design, evaluation model, calibration procedure, accuracy, previous experience, commercial availability, etc. Special attention has been paid to the behaviour of the measuring transducers when exposed to radiation. First, the performance of the instruments was compared with the requirements of PHEBUS. The results of this comparison served as the basis for a measuring concept in tabular form, giving the locations of the measurements, the measuring tasks, and the number and kind of instruments that are recommended. Redundancy and cost-benefit aspects have been taken into account in qualitative terms

  13. Calibration through on-line monitoring of instruments channels

    International Nuclear Information System (INIS)

    James, R.W.

    1996-01-01

    Plant technical specifications require periodic calibration of instrument channels, and this has traditionally meant calibration at fixed time intervals for nearly all instruments. Experience has shown that unnecessarily frequent calibrations reduce channel availability and reliability, impact outage durations, and increase maintenance costs. An alternative approach to satisfying existing requirements for periodic calibration consists of on-line monitoring and quantitative comparison of instrument channels during operation to identify instrument degradation and failure. A Utility Working Group has been formed by EPRI to support the technical activities necessary to achieve generic NRC acceptance of on-line monitoring of redundant instrument channels as a basis for determining when to perform calibrations. A topical report proposing NRC acceptance of this approach was submitted in August 1995, and the Working Group is currently resolving NRC technical questions. This paper describes the proposed approach and the current status of the topical report with regard to NRC review. While these activities will not preclude utilities from continuing to use existing calibration approaches, successful acceptance of this performance-based approach will allow utilities to substantially reduce the number of calibrations which are performed. Concurrent benefits will include reduced I ampersand C impact on outage durations and improved sensitivity to instrument channel performance

  14. Nuclear power plant control and instrumentation in Italy

    International Nuclear Information System (INIS)

    Lantieri, A.

    1992-01-01

    The National Energy Plan (PEN) approved by the Government of Italy in August 1988 provides a programme of research and industrial development or reactors with inherent and passive safety features. For the Control Systems and Instrumentation there is the aim to define rules and design criteria, by evaluating the impact of inherent safety goals on the C and I design. The effort on man-machine interface is considered essential to increase safety and efficiency of advanced reactors. The paper briefly describes the activity in control systems and in the instrumentation area. (author)

  15. Blunt dissection in augmentation mammaplasty-an instrumental aid.

    Science.gov (United States)

    Webster, R C; Pedroza, L V; Smith, R C; Smith, K F

    1981-11-01

    The iconoclast is an instrument that facilitates blunt dissection in areas where this basic technique is difficult because of anatomical or postsurgical adherence. Medical and inferior undermining in augmentation mammaplasty in primary and revisional cases is described. The instrument capitalizes on the gripping rather than the spreading strength of the surgeon's hand, allows easy penetration of tissues to be spread apart, and diminished severance of blood vessels. We have used the iconoclast for almost two years in selected cases and have had no problems or complications attributable to it.

  16. Instrumentation needs in LWR severe fuel damage experiments

    International Nuclear Information System (INIS)

    McCormick, R.D.

    1980-01-01

    The Class 9 type nuclear accident is defined and the Three Mile Island type accident and proposed Idaho National Engineering Laboratory experiment series are described in some detail. Different types of severe fuel damage experiments are briefly discussed in order to show typical measurement requirements. General instrumentation needs and problems encountered in Class 9 accident research are outlined. It is concluded that the extremely high temperatures, high nuclear radiation fields, and oxidizing atmosphere will necessitate instrument development programs. Noncontact type sensing will be necessary in most of the molten core experiments

  17. Build of virtual instrument laboratory related to nuclear species specialized

    International Nuclear Information System (INIS)

    Shan Jian; Zhao Guizhi; Zhao Xiuliang; Tang Lingzhi

    2009-01-01

    As rapid development of specialized related to nuclear science,the requirement of laboratory construct is analyzed in this article at first, One total conceive, One scheme deploy soft and hardware,three concrete characteristics targets and five different phases of put in practice of virtual instrument laboratory of specialized related to nuclear science are suggest in the paper,the concrete hardware structure and the headway of build of virtual instrument laboratory are described,and the first step effect is introduced.Lastly,the forward target and the further deliberateness that the virtual instrument laboratory construct are set forth in the thesis. (authors)

  18. Trials, tribulations, and pitfalls using commercial instruments for data acquisition

    International Nuclear Information System (INIS)

    Lee, R.C.; Olsen, R.H.; Unger, K.L.

    2009-01-01

    Brookhaven National Laboratory's Relativistic Heavy Ion Collider (RHIC) uses many commercially available instruments - for example spectrum analyzers, oscilloscopes, digital volt meters, signal generators - as integral parts of instrumentation and control systems. Typically these systems are remotely controlled. Using commercial instruments has many benefits. Manufactures have the skill, knowledge, and experience to produce high quality products. The price performance ratio is hard to duplicate. There are also disadvantages. Proprietary interfaces, single platform drivers, and reliable operation provide challenges for implementation and unattended operation. Several of the systems used at RHIC will be described. Their issues and solutions will be presented.

  19. Efficiency of lung ventilation for people performing wind instruments.

    Science.gov (United States)

    Brzęk, Anna; Famuła, Anna; Kowalczyk, Anna; Plinta, Ryszard

    Wind instruments musicians are particularly prone to excessive respiratory efforts. Prolonged wind instruments performing may lead to changes in respiratory tracts and thus to respiratory muscles overload. It may result in decreasing lung tissue pliability and, as a consequence, in emphysema. Aim of the research has been to describe basic spirometric parameters for wind players and causes of potential changes. Slow and forced spirometry with the use of Micro Lab Viasys (Micro Medical, Great Britain) was conducted on 31 wind musicians (group A). A survey concerning playing time and frequency, weight of instruments, and education on diaphragmatic breathing was conducted. The control group included 34 healthy persons at similar age (group B). The results were statistically described using Excel and Statistica programmes. The respiratory parameters were within the range of physiological norms and forced expiratory volume in 1 s to forced vital capacity (FEV1/FVC) exceeded in both groups the values of 100%. Forced vital capacity and expiratory vital capacity (EVC) values were significantly lower in the group of musicians than in the control group (p wind instrument. Spirometric parameters relative to standards may prove a good respiratory capacity. Peak expiratory flow (PEF) and FEV1 may indicate that a proper technique of respiration during performance was acquired. The length of time when performing wind instrument may influence parameters of dynamic spirometry. Med Pr 2016;67(4):427-433. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  20. AC Initiation System.

    Science.gov (United States)

    An ac initiation system is described which uses three ac transmission signals interlocked for safety by frequency, phase, and power discrimination...The ac initiation system is pre-armed by the application of two ac signals have the proper phases, and activates a load when an ac power signal of the proper frequency and power level is applied. (Author)

  1. Penetrating eye injuries from writing instruments

    Directory of Open Access Journals (Sweden)

    Kelly SP

    2011-12-01

    Full Text Available Simon P Kelly, Graham MB ReevesThe Royal Bolton Hospital, Bolton, UKPurpose: To consider the potential for ocular injury from writing implements by presenting four such cases, and to consider the incidence of such eye injuries from analysis of a national trauma database.Methods: The Home and Leisure Accident Surveillance System was searched for records of eye injuries from writing instruments to provide UK estimates of such injuries. Four patients with ocular penetrating injury from pens or pencils (especially when caused by children, and examined by the authors, are described which illustrate mechanisms of injury.Results: It is estimated that around 748 ocular pen injuries and 892 ocular pencil injuries of undetermined severity occurred annually in the UK during the database surveillance period 2000–2002. No eye injuries from swords, including toy swords and fencing foils, were reported.Conclusion: Ocular perforation sometimes occur from writing instruments that are thrown in the community, especially by children. Implications for policy and prevention are discussed. Non-specialists should have a low threshold for referring patients with eye injuries if suspicious of ocular penetration, even where caused by everyday objects, such as writing instruments.Keywords: eye injury, eye, children, mechanism, writing instruments, prevention

  2. Initial Development Work for the Cloud-Aerosol Multi-Angle Lidar

    Data.gov (United States)

    National Aeronautics and Space Administration — Initiate development of a cost-effective off-nadir cloud-aerosol lidar instrument to enable data synergy with passive sensors (imagers, polarimeters) and models...

  3. Standard guide for evaluating performance characteristics of phased-Array ultrasonic testing instruments and systems

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide describes procedures for evaluating some performance characteristics of phased-array ultrasonic examination instruments and systems. 1.2 Evaluation of these characteristics is intended to be used for comparing instruments and systems or, by periodic repetition, for detecting long-term changes in the characteristics of a given instrument or system that may be indicative of impending failure, and which, if beyond certain limits, will require corrective maintenance. Instrument characteristics measured in accordance with this guide are expressed in terms that relate to their potential usefulness for ultrasonic examinations. Other electronic instrument characteristics in phased-array units are similar to non-phased-array units and may be measured as described in E 1065 or E 1324. 1.3 Ultrasonic examination systems using pulsed-wave trains and A-scan presentation (rf or video) may be evaluated. 1.4 This guide establishes no performance limits for examination systems; if such acceptance criteria ar...

  4. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  5. Design of cost effective antennas for instrumentation radars

    CSIR Research Space (South Africa)

    Botha, L

    2012-09-01

    Full Text Available The cost of antennas for instrumentation radars are determined by the development cost. By re-use of the reflector system cost effective antennas can be designed. The factors governing the design of such antennas are described here....

  6. Instrumentness for Creativity - Mediation, Materiality & Metonymy

    DEFF Research Database (Denmark)

    Bertelsen, Olav Wedege; Breinbjerg, Morten; Pold, Søren

    2007-01-01

    in use beyond what is initially designed for. The paper performs a conceptual investigation into qualities in software interfaces that support creativity, supported by analysis of, and interviews with, musical composers. Instrumentness is explained through discussions of materiality and metonymy...... as central strategies for computer mediated creativity. The paper is contributing to an investigation of the aesthetics of use in relation to software, pointing to alternative values, differing from traditional usability, which are also relevant in creative work outside art and music composition....

  7. Assessing patient-centred communication in teaching: a systematic review of instruments.

    Science.gov (United States)

    Brouwers, Marianne; Rasenberg, Ellemieke; van Weel, Chris; Laan, Roland; van Weel-Baumgarten, Evelyn

    2017-11-01

    Patient-centred communication is a key component of patient centredness in medical care. Therefore, adequate education in and assessment of patient-centred communication skills are necessary. In general, feedback on communication skills is most effective when it is provided directly and is systematic. This calls for adequate measurement instruments. The aim of this study was to provide a systematic review of existing instruments that measure patient centredness in doctor-patient communication and can be used to provide direct feedback. A systematic review was conducted using an extensive validated search strategy for measurement instruments in PubMed, EMBASE, PsycINFO and CINAHL. The databases were searched from their inception to 1 July 2016. Articles describing the development or evaluation of the measurement properties of instruments that measure patient centredness (by applying three or more of the six dimensions of a published definition of patient centredness) in doctor-patient communication and that can be used for the provision of direct feedback were included. The methodological quality of measurement properties was evaluated using the COSMIN checklist. Thirteen articles describing 14 instruments measuring patient centredness in doctor-patient communication were identified. These studies cover a wide range of settings and patient populations, and vary in the dimensions of patient centredness applied and in methodological quality on aspects of reliability and validity. This review gives a comprehensive overview of all instruments available for the measurement of patient centredness in doctor-patient communication that can be used for the provision of direct feedback and are described in the literature. Despite the widely felt need for valid and reliable instruments for the measurement of patient-centred communication, most of the instruments currently available have not been thoroughly investigated. Therefore, we recommend further research into and

  8. Comparison and selection of client computer in nuclear instrument

    International Nuclear Information System (INIS)

    Ma Guizhen; Xie Yanhui; Peng Jing; Xu Feiyan

    2012-01-01

    The function of modern new nuclear instrument is very much. And the information degree is high requested. Through close matching for host computer and client computer, the data processing function can be carried out. This article puts forward a few of projects for the client computer of general nuclear instrument. The function and features of several common client computers, such as FPGA, ARM and DSP, are analyzed and compared. The applied scope is discussed also. At the same time, using a practical design as an example, the selection ideas of client computer are described. This article can be used for reference for the hardware design of data acquisition processing unit in nuclear instrument. (authors)

  9. Applying improved instrumentation and computer control systems

    International Nuclear Information System (INIS)

    Bevilacqua, F.; Myers, J.E.

    1977-01-01

    In-core and out-of-core instrumentation systems for the Cherokee-I reactor are described. The reactor has 61m-core instrument assemblies. Continuous computer monitoring and processing of data from over 300 fixed detectors will be used to improve the manoeuvering of core power. The plant protection system is a standard package for the Combustion Engineering System 80, consisting of two independent systems, the reactor protection system and the engineering safety features activation system, both of which are designed to meet NRC, ANS and IEEE design criteria or standards. The plants protection system has its own computer which provides plant monitoring, alarming, logging and performance calculations. (U.K.)

  10. The Gem Infrasound Logger and Custom-Built Instrumentation

    International Nuclear Information System (INIS)

    Anderson, Jacob F.; Ronan, Timothy J.

    2017-01-01

    Here, we designed, built, and recorded data with a custom infrasound logger (referred to as the Gem) that is inexpensive, portable, and easy to use. We also describe its design process, qualities, and applications in this article. Field instrumentation is a key element of geophysical data collection, and the quantity and quality of data that can be recorded is determined largely by the characteristics of the instruments used. Geophysicists tend to rely on commercially available instruments, which suffice for many important types of fieldwork. However, commercial instrumentation can fall short in certain roles, which motivates the development of custom sensors and data loggers. Particularly, we found existing data loggers to be expensive and inconvenient for infrasound campaigns, and developed the Gem infrasound logger in response. In this article, we discuss development of this infrasound logger and the various uses found for it, including projects on volcanoes, high-altitude balloons, and rivers. Further, we demonstrate that when needed, scientists can feasibly design and build their own specialized instruments, and that doing so can enable them to record more and better data at a lower cost.

  11. Instrument accuracy in reactor vessel inventory tracking systems

    International Nuclear Information System (INIS)

    Anderson, J.L.; Anderson, R.L.; Morelock, T.C.; Hauang, T.L.; Phillips, L.E.

    1986-01-01

    Instrumentation needs for detection of inadequate core cooling. Studies of the Three Mile Island accident identified the need for additional instrumentation to detect inadequate core cooling (ICC) in nuclear power plants. Industry studies by plant owners and reactor vendors supported the conclusion that improvements were needed to help operators diagnose the approach to or existence of ICC as well as to provide more complete information for operator control of safety injection flow to minimize the consequences of such an accident. In 1980, the US Nuclear Regulatory Commission (NRC) required further studies by the industry and described ICC instrumentation design requirements that included human factors and environmental considerations. On December 10, 1982, NRC issued to Babcock and Wilcox (B and W) licensees orders for Modification of License and transmitted to pressurized water reactor licensees Generic Letter 82-28 to inform them of the revised NRC requirements. The instrumentation requirements include upgraded subcooling margin monitors (SMM), upgraded core exit thermocouples (CET), and installation of a reactor coolant inventory tracking system. NRC Regulatory Guide 1.97, which covers accident monitoring instrumentation, was revised (Rev. 3) to be consistent with the requirements of item II.F.2 of NUREG-0737

  12. Aversive pavlovian responses affect human instrumental motor performance.

    Science.gov (United States)

    Rigoli, Francesco; Pavone, Enea Francesco; Pezzulo, Giovanni

    2012-01-01

    IN NEUROSCIENCE AND PSYCHOLOGY, AN INFLUENTIAL PERSPECTIVE DISTINGUISHES BETWEEN TWO KINDS OF BEHAVIORAL CONTROL: instrumental (habitual and goal-directed) and Pavlovian. Understanding the instrumental-Pavlovian interaction is fundamental for the comprehension of decision-making. Animal studies (as those using the negative auto-maintenance paradigm), have demonstrated that Pavlovian mechanisms can have maladaptive effects on instrumental performance. However, evidence for a similar effect in humans is scarce. In addition, the mechanisms modulating the impact of Pavlovian responses on instrumental performance are largely unknown, both in human and non-human animals. The present paper describes a behavioral experiment investigating the effects of Pavlovian conditioned responses on performance in humans, focusing on the aversive domain. Results showed that Pavlovian responses influenced human performance, and, similar to animal studies, could have maladaptive effects. In particular, Pavlovian responses either impaired or increased performance depending on modulator variables such as threat distance, task controllability, punishment history, amount of training, and explicit punishment expectancy. Overall, these findings help elucidating the computational mechanisms underlying the instrumental-Pavlovian interaction, which might be at the base of apparently irrational phenomena in economics, social behavior, and psychopathology.

  13. Aversive Pavlovian responses affect human instrumental motor performance

    Directory of Open Access Journals (Sweden)

    Francesco eRigoli

    2012-10-01

    Full Text Available In neuroscience and psychology, an influential perspective distinguishes between two kinds of behavioural control: instrumental (habitual and goal-directed and Pavlovian. Understanding the instrumental-Pavlovian interaction is fundamental for the comprehension of decision-making. Animal studies (as those using the negative auto-maintenance paradigm, have demonstrated that Pavlovian mechanisms can have maladaptive effects on instrumental performance. However, evidence for a similar effect in humans is scarce. In addition, the mechanisms modulating the impact of Pavlovian responses on instrumental performance are largely unknown, both in human and non-human animals. The present paper describes a behavioural experiment investigating the effects of Pavlovian conditioned responses on performance in humans, focusing on the aversive domain. Results showed that Pavlovian responses influenced human performance, and, similar to animal studies, could have maladaptive effects. In particular, Pavlovian responses either impaired or increased performance depending on modulator variables such as threat distance, task controllability, punishment history, amount of training, and explicit punishment expectancy. Overall, these findings help elucidating the computational mechanisms underlying the instrumental-Pavlovian interaction, which might be at the base of apparently irrational phenomena in economics, social behaviour, and psychopathology.

  14. Instrument design and automation

    International Nuclear Information System (INIS)

    Wernlund, R.F.

    1984-01-01

    The ion mobility spectrometer-mass spectrometer (IMS-MS) is described and consists of two separate instruments coupled in tandem: an ion mobility spectrometer coupled to a quadrupole mass spectrometer. The two insturments operate at different pressures in a synergistic manner, supplying both drift time and mass information about ions which are formed at atmospheric pressure in the ion mobility spectrometer tube. Two types of ion intensity signals are presented to the data processor. The IMS produces an analog voltage with major components from dc to 5 KHz. The mass spectrometer signal output resides in the pulse count rate derived from a series of TTL level pulses where each pulse represents the arrival of a single ion. The hardware, software, interfacing capabilities and basic data acquisition program are described in detail

  15. Instrument-related geometrical factors affecting the intensity in XPS and ARXPS experiments

    Energy Technology Data Exchange (ETDEWEB)

    Herrera-Gomez, A., E-mail: aherrera@qro.cinvestav.mx [CINVESTAV-Unidad Queretaro, Queretaro 76230 (Mexico); Aguirre-Tostado, F.S. [Centro de Investigacion en Materiales Avanzados, Apodaca, Nuevo Leon 66600 (Mexico); Mani-Gonzalez, P.G.; Vazquez-Lepe, M.; Sanchez-Martinez, A.; Ceballos-Sanchez, O. [CINVESTAV-Unidad Queretaro, Queretaro 76230 (Mexico); Wallace, R.M. [Materials Science and Engineering, University of Texas at Dallas, Richardson, TX 75080 (United States); Conti, G.; Uritsky, Y. [Applied Materials, Santa Clara, CA 95054 (United States)

    2011-11-15

    Highlights: {yields} Instrument geometrical-factors affecting the XPS angular dependence are described. {yields} The geometrical factors in XPS instruments are transferable to other systems. {yields} Practical protocols are presented for assessing the size of analysis area and volume. {yields} Practical protocols are presented for assessing the size of the X-ray beam spot. {yields} Practical protocols are described for assessing the manipulator's axis of rotation. - Abstract: The angular dependence of the X-ray photoelectron spectroscopy (XPS) signal is influenced not only by the electron take-off angle, but also by instrument-related geometrical factors. The XPS signal is, in fact, integrated over the overlap between the X-ray beam, the spectrometer analysis volume, and the sample surface. This overlap depends on the size and shape of the spectrometer analysis volume and X-ray beam, as well as on their relative orientation. In this paper it is described the models and protocols for the characterization of the parameters defining the geometry of an XPS instrument. The protocols include practical methods for assessing the spectrometer analysis area and the X-ray beam spot dimension. Simple systems consisting of flat and 'thick' gold films on silicon wafers were employed. The parameters found with those samples are transferable to other more complex systems since they are geometrical in nature. The method allows for the prediction of the actual intensity of XPS peaks, hence removing the need of normalizing the peak areas to the area of a determined substrate peak. The associated reduction of the uncertainty in half is of special importance since the quantitative analysis of angle-resolved XPS data could be very sensitive to noise. Two rotating and one non-rotating XPS instruments are described. Some examples of the applications of the method are also provided.

  16. 26 CFR 1.508-3 - Governing instruments.

    Science.gov (United States)

    2010-04-01

    ... foundation shall not be exempt from taxation under section 501(a) for a taxable year unless by the end of... described in section 4947(a)) that its governing instrument contains no mandatory directions which conflict...(e), such organization will not be exempt from taxation. (6) Retroactive application to grants or...

  17. Wavefront-Error Performance Characterization for the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) Science Instruments

    Science.gov (United States)

    Aronstein, David L.; Smith, J. Scott; Zielinski, Thomas P.; Telfer, Randal; Tournois, Severine C.; Moore, Dustin B.; Fienup, James R.

    2016-01-01

    The science instruments (SIs) comprising the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) were tested in three cryogenic-vacuum test campaigns in the NASA Goddard Space Flight Center (GSFC)'s Space Environment Simulator (SES). In this paper, we describe the results of optical wavefront-error performance characterization of the SIs. The wavefront error is determined using image-based wavefront sensing (also known as phase retrieval), and the primary data used by this process are focus sweeps, a series of images recorded by the instrument under test in its as-used configuration, in which the focal plane is systematically changed from one image to the next. High-precision determination of the wavefront error also requires several sources of secondary data, including 1) spectrum, apodization, and wavefront-error characterization of the optical ground-support equipment (OGSE) illumination module, called the OTE Simulator (OSIM), 2) plate scale measurements made using a Pseudo-Nonredundant Mask (PNRM), and 3) pupil geometry predictions as a function of SI and field point, which are complicated because of a tricontagon-shaped outer perimeter and small holes that appear in the exit pupil due to the way that different light sources are injected into the optical path by the OGSE. One set of wavefront-error tests, for the coronagraphic channel of the Near-Infrared Camera (NIRCam) Longwave instruments, was performed using data from transverse translation diversity sweeps instead of focus sweeps, in which a sub-aperture is translated andor rotated across the exit pupil of the system.Several optical-performance requirements that were verified during this ISIM-level testing are levied on the uncertainties of various wavefront-error-related quantities rather than on the wavefront errors themselves. This paper also describes the methodology, based on Monte Carlo simulations of the wavefront-sensing analysis of focus-sweep data, used to establish the

  18. The Complexity integrated-Instruments components media of IPA at Elementary School

    Directory of Open Access Journals (Sweden)

    Angreni Siska

    2018-01-01

    Full Text Available This research aims at describing the complexity of Integrated Instrument Components media (CII in learning of science at Elementary schools in District Siulak Mukai and at Elementary schools in District Siulak. The research applied a descriptive method which included survey forms. Instruments used were observation sheets. The result of the research showed Integrated Instrument Components media (CII natural science that complexity at primary school district Siulak was more complex compared with that at primary school district Siulak Mukai. is better than from primary school district Mukai

  19. Modernization of the Ukrainian NPP instrumentation and control systems

    International Nuclear Information System (INIS)

    Yastrebenetsky, M.

    1998-01-01

    Modernization of many instrumentation and control systems for all type of reactors is under way now in Ukraine. Main principles of modernization, standards that are used for modernization are described in the report. (author)

  20. The Atacama Cosmology Telescope: The Polarization-Sensitive ACTPol Instrument

    Science.gov (United States)

    Thornton, R. J.; Ade, P. A. R.; Aiola, S.; Angile, F. E.; Amiri, M.; Beall, J. A.; Becker, D. T.; Cho, H.-M.; Choi, S. K.; Corlies, P.; hide

    2016-01-01

    The Atacama Cosmology Telescope (ACT) makes high angular resolution measurements of anisotropies in the Cosmic Microwave Background (CMB) at millimeter wavelengths. We describe ACTPol, an upgraded receiver for ACT, which uses feedhorn-coupled, polarization-sensitive detector arrays, a 3deg field of view, 100 mK cryogenics with continuous cooling, and meta material antireflection coatings. ACTPol comprises three arrays with separate cryogenic optics: two arrays at a central frequency of 148 GHz and one array operating simultaneously at both 97 GHz and 148 GHz. The combined instrument sensitivity, angular resolution, and sky coverage are optimized for measuring angular power spectra, clusters via the thermal Sunyaev-Zel'dovich (SZ) and kinetic SZ signals, and CMB lensing due to large-scale structure. The receiver was commissioned with its first 148 GHz array in 2013, observed with both 148 GHz arrays in 2014, and has recently completed its first full season of operations with the full suite of three arrays. This paper provides an overview of the design and initial performance of the receiver and related systems.

  1. The Atacama Cosmology Telescope: The Polarization-sensitive ACTPol Instrument

    Science.gov (United States)

    Thornton, R. J.; Ade, P. A. R.; Aiola, S.; Angilè, F. E.; Amiri, M.; Beall, J. A.; Becker, D. T.; Cho, H.-M.; Choi, S. K.; Corlies, P.; Coughlin, K. P.; Datta, R.; Devlin, M. J.; Dicker, S. R.; Dünner, R.; Fowler, J. W.; Fox, A. E.; Gallardo, P. A.; Gao, J.; Grace, E.; Halpern, M.; Hasselfield, M.; Henderson, S. W.; Hilton, G. C.; Hincks, A. D.; Ho, S. P.; Hubmayr, J.; Irwin, K. D.; Klein, J.; Koopman, B.; Li, Dale; Louis, T.; Lungu, M.; Maurin, L.; McMahon, J.; Munson, C. D.; Naess, S.; Nati, F.; Newburgh, L.; Nibarger, J.; Niemack, M. D.; Niraula, P.; Nolta, M. R.; Page, L. A.; Pappas, C. G.; Schillaci, A.; Schmitt, B. L.; Sehgal, N.; Sievers, J. L.; Simon, S. M.; Staggs, S. T.; Tucker, C.; Uehara, M.; van Lanen, J.; Ward, J. T.; Wollack, E. J.

    2016-12-01

    The Atacama Cosmology Telescope (ACT) makes high angular resolution measurements of anisotropies in the Cosmic Microwave Background (CMB) at millimeter wavelengths. We describe ACTPol, an upgraded receiver for ACT, which uses feedhorn-coupled, polarization-sensitive detector arrays, a 3° field of view, 100 mK cryogenics with continuous cooling, and meta material antireflection coatings. ACTPol comprises three arrays with separate cryogenic optics: two arrays at a central frequency of 148 GHz and one array operating simultaneously at both 97 GHz and 148 GHz. The combined instrument sensitivity, angular resolution, and sky coverage are optimized for measuring angular power spectra, clusters via the thermal Sunyaev–Zel’dovich (SZ) and kinetic SZ signals, and CMB lensing due to large-scale structure. The receiver was commissioned with its first 148 GHz array in 2013, observed with both 148 GHz arrays in 2014, and has recently completed its first full season of operations with the full suite of three arrays. This paper provides an overview of the design and initial performance of the receiver and related systems.

  2. SAS3DC - A computer program to describe accidents in LMFBRs

    International Nuclear Information System (INIS)

    Angerer, G.; Arnecke, G.; Polch, A.

    1981-02-01

    The code system SAS3D - developed in the ANL - is at present the most adequate instrument for simulating accidents in the LMFBRs. SAS3DC is an improved version of this code system: the routine CLAZAS - modelling in SAS3D the motion of the fuel cladding - is replaced in the SAS3DC by the routine CMOT. CMOT describes the moving material not in the Lagrangian - as CLAZAS - but in the Eulerian system and is so able to register even small cladding-displacements. To complete the description of the SAS3DC-code the results of some sample problems are included. (orig.) [de

  3. Instrumental interaction

    OpenAIRE

    Luciani , Annie

    2007-01-01

    International audience; The expression instrumental interaction as been introduced by Claude Cadoz to identify a human-object interaction during which a human manipulates a physical object - an instrument - in order to perform a manual task. Classical examples of instrumental interaction are all the professional manual tasks: playing violin, cutting fabrics by hand, moulding a paste, etc.... Instrumental interaction differs from other types of interaction (called symbolic or iconic interactio...

  4. A Mixed Methods Portrait of Urban Instrumental Music Teaching

    Science.gov (United States)

    Fitzpatrick, Kate R.

    2011-01-01

    The purpose of this mixed methods study was to learn about the ways that instrumental music teachers in Chicago navigated the urban landscape. The design of the study most closely resembles Creswell and Plano Clark's (2007) two-part Triangulation Convergence Mixed Methods Design, with the addition of an initial exploratory focus group component.…

  5. Seismic refraction profile, Kingdom of Saudi Arabia: field operations, instrumentation, and initial results

    Science.gov (United States)

    Blank, H. Richard; Healy, J.H.; Roller, John; Lamson, Ralph; Fisher, Fred; McClearn, Robert; Allen, Steve

    1979-01-01

    In February 1978 a seismic deep-refraction profile was recorded by the USGS along a 1000-km line across the Arabian Shield in western Saudi Arabia. The line begins in Paleozoic and Mesozoic cover rocks near Riyadh on the Arabian Platform, leads southwesterly across three major Precambrian tectonic provinces, traverses Cenozoic rocks of the coastal plain near Jizan (Tihamat Asir), and terminates at the outer edge of the Farasan Bank in the southern Red Sea. More than 500 surveyed recording sites were occupied, including 19 in the Farasan Islands. Six shot points were used--five on land, with charges placed mostly below water table in drill holes, and one at sea, with charges placed on the sea floor and fired from a ship. The total charge consumed was slightly in excess of 61 metric tons in 21 discrete firings. Seismic energy was recorded by means of a set of 100 newly developed portable seismic stations. Each station consists of a standard 2-Hz vertical geophone coupled to a self-contained analog recording instrument equipped with a magnetic-tape cassette. The stations were deployed in groups of 20 by five observer teams, each generally consisting of two scientist-technicians and a surveyor-guide. On the day prior to deployment, the instruments were calibrated and programmed for automatic operation by means of a specially designed device called a hand-held tester. At each of ten pre-selected recording time windows on a designated firing day, the instruments were programmed to turn on, stabilize, record internal calibration signals, record the seismic signals at three levels of amplification, and then deactivate. After the final window in the firing sequence, all instruments were retrieved and their data tapes removed for processing. A specially designed, field tape- dubbing system was utilized at shot point camps to organize and edit data recorded on the cassette tapes. The main functions of this system are to concatenate all data from each shot on any given day

  6. The knowledge, efficacy, and practices instrument for oral health providers: a validity study with dental students.

    Science.gov (United States)

    Behar-Horenstein, Linda S; Garvan, Cyndi W; Moore, Thomas E; Catalanotto, Frank A

    2013-08-01

    Valid and reliable instruments to measure and assess cultural competence for oral health care providers are scarce in the literature, and most published scales have been contested due to a lack of item analysis and internal estimates of reliability. The purposes of this study were, first, to develop a standardized instrument to measure dental students' knowledge of diversity, skills in culturally competent patient-centered communication, and use of culture-centered practices in patient care and, second, to provide preliminary validity support for this instrument. The initial instrument used in this study was a thirty-six-item Likert-scale survey entitled the Knowledge, Efficacy, and Practices Instrument for Oral Health Providers (KEPI-OHP). This instrument is an adaption of an initially thirty-three-item version of the Multicultural Awareness, Knowledge, and Skills Scale-Counselor Edition (MAKSS-CE), a scale that assesses factors related to social justice, cultural differences among clients, and cross-cultural client management. After the authors conducted cognitive and expert interviews, focus groups, pilot testing, and item analysis, their initial instrument was reduced to twenty-eight items. The KEPI-OHP was then distributed to 916 dental students (response rate=48.6 percent) across the United States to measure its reliability and assess its validity. Both exploratory and confirmatory factor analyses were conducted to test the scale's validity. The modification of the survey into a sensible instrument with a relatively clear factor structure using factor analysis resulted in twenty items. A scree test suggested three expressive factors, which were retained for rotation. Bentler's comparative fit and Bentler and Bonnett's non-normed indices were 0.95 and 0.92, respectively. A three-factor solution, including efficacy of assessment, knowledge of diversity, and culture-centered practice subscales, comprised of twenty-items was identified. The KEPI-OHP was found to

  7. Flight experience with lightweight, low-power miniaturized instrumentation systems

    Science.gov (United States)

    Hamory, Philip J.; Murray, James E.

    1992-01-01

    Engineers at the NASA Dryden Flight Research Facility (NASA-Dryden) have conducted two flight research programs with lightweight, low-power miniaturized instrumentation systems built around commercial data loggers. One program quantified the performance of a radio-controlled model airplane. The other program was a laminar boundary-layer transition experiment on a manned sailplane. The purpose of this paper is to report NASA-Dryden personnel's flight experience with the miniaturized instrumentation systems used on these two programs. The paper will describe the data loggers, the sensors, and the hardware and software developed to complete the systems. The paper also describes how the systems were used and covers the challenges encountered to make them work. Examples of raw data and derived results will be shown as well. Finally, future plans for these systems will be discussed.

  8. Instrumentation development

    International Nuclear Information System (INIS)

    Ubbes, W.F.; Yow, J.L. Jr.

    1988-01-01

    Instrumentation is developed for the Civilian Radioactive Waste Management Program to meet several different (and sometimes conflicting) objectives. This paper addresses instrumentation development for data needs that are related either directly or indirectly to a repository site, but does not touch on instrumentation for work with waste forms or other materials. Consequently, this implies a relatively large scale for the measurements, and an in situ setting for instrument performance. In this context, instruments are needed for site characterization to define phenomena, develop models, and obtain parameter values, and for later design and performance confirmation testing in the constructed repository. The former set of applications is more immediate, and is driven by the needs of program design and performance assessment activities. A host of general technical and nontechnical issues have arisen to challenge instrumentation development. Instruments can be classed into geomechanical, geohydrologic, or other specialty categories, but these issues cut across artificial classifications. These issues are outlined. Despite this imposing list of issues, several case histories are cited to evaluate progress in the area

  9. A review of instruments to measure interprofessional team-based primary care.

    Science.gov (United States)

    Shoemaker, Sarah J; Parchman, Michael L; Fuda, Kathleen Kerwin; Schaefer, Judith; Levin, Jessica; Hunt, Meaghan; Ricciardi, Richard

    2016-07-01

    Interprofessional team-based care is increasingly regarded as an important feature of delivery systems redesigned to provide more efficient and higher quality care, including primary care. Measurement of the functioning of such teams might enable improvement of team effectiveness and could facilitate research on team-based primary care. Our aims were to develop a conceptual framework of high-functioning primary care teams to identify and review instruments that measure the constructs identified in the framework, and to create a searchable, web-based atlas of such instruments (available at: http://primarycaremeasures.ahrq.gov/team-based-care/ ). Our conceptual framework was developed from existing frameworks, the teamwork literature, and expert input. The framework is based on an Input-Mediator-Output model and includes 12 constructs to which we mapped both instruments as a whole, and individual instrument items. Instruments were also reviewed for relevance to measuring team-based care, and characterized. Instruments were identified from peer-reviewed and grey literature, measure databases, and expert input. From nearly 200 instruments initially identified, we found 48 to be relevant to measuring team-based primary care. The majority of instruments were surveys (n = 44), and the remainder (n = 4) were observational checklists. Most instruments had been developed/tested in healthcare settings (n = 30) and addressed multiple constructs, most commonly communication (n = 42), heedful interrelating (n = 42), respectful interactions (n = 40), and shared explicit goals (n = 37). The majority of instruments had some reliability testing (n = 39) and over half included validity testing (n = 29). Currently available instruments offer promise to researchers and practitioners to assess teams' performance, but additional work is needed to adapt these instruments for primary care settings.

  10. Parameters of Instrumental Swallowing Evaluations: Describing a Diagnostic Dilemma.

    Science.gov (United States)

    Pisegna, Jessica M; Langmore, Susan E

    2016-06-01

    The aim of this study was to compare selected parameters of two swallow evaluations: fiberoptic endoscopic evaluation of swallowing (FEES) and the modified barium swallow (MBS) study. This was a cross-sectional, descriptive study. Fifty-five clinicians were asked to watch video recordings of swallow evaluations of 2 patients that were done using fluoroscopy and endoscopy simultaneously. In a randomized order, clinicians viewed 4 edited videos from simultaneous evaluations: the FEES and MBS videos of patient 1 and 2 each taking one swallow of 5 mL applesauce. Clinicians filled out a questionnaire that asked (1) which anatomical sites they could visualize on each video, (2) where they saw pharyngeal residue after a swallow, (3) their overall clinical impression of the pharyngeal residue, and (4) their opinions of the evaluation styles. Clinicians reported a significant difference in the visualization of anatomical sites, 11 of the 15 sites were reported as better-visualized on the FEES than on the MBS video (p < 0.05). Clinicians also rated residue to be present in more locations on the FEES than on the MBS. Clinicians' overall impressions of the severity of residue on the same exact swallow were significantly different depending on the evaluation type (FEES vs. MBS for patient 1 χ(2) = 20.05, p < 0.0001; patient 2 χ(2) = 7.52, p = 0.006), with FEES videos rated more severely. FEES advantages were: more visualization of pharyngeal and laryngeal swallowing anatomy and residue. However, as a result, clinicians provided more severe impressions of residue amount on FEES. On one hand, this suggests that FEES is a more sensitive tool than MBS studies, but on the other hand, clinicians might provide more severe interpretations on FEES.

  11. The Development of an ASSA Module as an Auxiliary Tool for Assessment of Existing Plant Instrumentation and enhancement of the instruments performance

    International Nuclear Information System (INIS)

    Koo, Kil Mo; Kang, Kyung Ho; Ha, Kwang Soon; Cho, Young Ro; Cho, Young; Park, Rae Jun; Kim, Sang Baik; Kim, Hee Dong

    2007-04-01

    A review of a plant's accident management capabilities is one of the key elements in achieving regulatory closure of severe accident issues. During accidents, information and data from plant's instruments, as well as others sources, are essential for assessing the plant's status and response. Unlike for design basis accidents, there are inherently some uncertainties to instrumentation capabilities for severe accident conditions. There are many ways to obtain information during a severe accident. Moreover, precise measurements are not necessary. The redundancy and ruggedness of a plant's instrumentation provides considerable depth in the capability of existing designs. The circuit simulation analysis and diagnosis methods are used to assess instruments in detail when they give apparently abnormal readings. A new simulator, ASSA(abnormal signal simulator analysis), through an analysis of the important circuits modeling under severe accident conditions has been designed. It has three main functions which are a signal processing tool, an accident management tool, and an additional guide from the initial screen. In this paper, it can be simulated to the temperature characteristic analysis procedure of the ASSA through EQ data comparative method and using specific signal processing under severe accident condition

  12. Instrument design and optimization using genetic algorithms

    International Nuclear Information System (INIS)

    Hoelzel, Robert; Bentley, Phillip M.; Fouquet, Peter

    2006-01-01

    This article describes the design of highly complex physical instruments by using a canonical genetic algorithm (GA). The procedure can be applied to all instrument designs where performance goals can be quantified. It is particularly suited to the optimization of instrument design where local optima in the performance figure of merit are prevalent. Here, a GA is used to evolve the design of the neutron spin-echo spectrometer WASP which is presently being constructed at the Institut Laue-Langevin, Grenoble, France. A comparison is made between this artificial intelligence approach and the traditional manual design methods. We demonstrate that the search of parameter space is more efficient when applying the genetic algorithm, and the GA produces a significantly better instrument design. Furthermore, it is found that the GA increases flexibility, by facilitating the reoptimization of the design after changes in boundary conditions during the design phase. The GA also allows the exploration of 'nonstandard' magnet coil geometries. We conclude that this technique constitutes a powerful complementary tool for the design and optimization of complex scientific apparatus, without replacing the careful thought processes employed in traditional design methods

  13. Instrument design and optimization using genetic algorithms

    Science.gov (United States)

    Hölzel, Robert; Bentley, Phillip M.; Fouquet, Peter

    2006-10-01

    This article describes the design of highly complex physical instruments by using a canonical genetic algorithm (GA). The procedure can be applied to all instrument designs where performance goals can be quantified. It is particularly suited to the optimization of instrument design where local optima in the performance figure of merit are prevalent. Here, a GA is used to evolve the design of the neutron spin-echo spectrometer WASP which is presently being constructed at the Institut Laue-Langevin, Grenoble, France. A comparison is made between this artificial intelligence approach and the traditional manual design methods. We demonstrate that the search of parameter space is more efficient when applying the genetic algorithm, and the GA produces a significantly better instrument design. Furthermore, it is found that the GA increases flexibility, by facilitating the reoptimization of the design after changes in boundary conditions during the design phase. The GA also allows the exploration of "nonstandard" magnet coil geometries. We conclude that this technique constitutes a powerful complementary tool for the design and optimization of complex scientific apparatus, without replacing the careful thought processes employed in traditional design methods.

  14. Instrumentation for PSD based neutron diffractometers at Dhruva reactor

    International Nuclear Information System (INIS)

    Pande, S.S.; Borkar, S.P.; Prafulla, S.; Srivastava, V.D.; Behare, A.; Mukhopadhyay, P.K.; Ghodgaonkar, M.D.; Kataria, S.K.

    2004-01-01

    Linear position sensitive detectors (PSDs) are widely used to configure neutron diffractometers and other instruments. Necessary front-end electronics and a data acquisition system is developed to cater to such instruments built around the Dhruva research reactor in BARC. These include three diffractometers with multiple PSDs and four with single PSD. The front-end electronics consists of high voltage units, preamplifiers, shaping amplifiers, ratio ADCs (RDC). The data acquisition system consists of an interface card and software. Commercially available hardware like temperature controller or stepper motor controller connected over GPIB or RS232 are also integrated in the data acquisition system. The data acquisition is automated so that it can continue unattended for control parameter like temperature, thus enabling optimum utilization of available beam time. The instrumentation is scalable and can be easily configured for various instrumental requirements. The front-end electronics and the data acquisition system are described here. (author)

  15. The KNK II instrumentation for global and local supervision of the reactor core

    International Nuclear Information System (INIS)

    Steiger, W.O.

    1991-01-01

    After an introduction into the KNK plant itself, their historical development and their present situation, the instrumentation of the global and local supervision of the KNK II-core as well as the main safety-related instrumentation and control systems is described. Special emphasis is laid on the instrumentation of the reactor protection systems and the shut down systems. After that some practices are reported about instrumentation behavior and lessons learned from the operation and maintenance of the above mentioned systems. At last follows a short description of the special instrumentation for the detection of failed fuel subassemblies and of the plant data processing system. (author). 4 refs, 18 tabs

  16. Development and initial validation of a caffeine craving questionnaire.

    Science.gov (United States)

    West, Oliver; Roderique-Davies, Gareth

    2008-01-01

    Craving for caffeine has received little empirical attention, despite considerable research into the potential for caffeine dependence. The main aim of this study was to develop, and initially validate, a multi-item, multidimensional instrument to measure cravings for caffeine. Participants were 189 caffeine consumers who completed the Questionnaire of Caffeine Cravings, which was based on the Questionnaire of Smoking Urges (QSU), in one of five naturally occurring periods of abstinence; 1-15 min; 16-120 mins; 3-7 h; 12-48 h and +48 h. Exploratory factor analysis suggested a three-factor solution best described the data; Factor 1 reflected strong desires, intentions and positive reinforcement; Factor 2 reflected mild/general positive and negative reinforcement and Factor 3 reflected functional/mood-based negative reinforcement. Significantly higher Factor 1 and Factor 2 scores were recorded for high frequency users; significantly higher Factor 1 and Factor 3 scores were recorded as a function of increased levels of dependence. Duration of abstinence did not significantly effect cravings across all three factors. Regression analyses suggested level of dependence best predicted both current cravings and frequency of daily use. These findings suggest caffeine cravings may be conceptualized multidimensionally and further validates the use of multidimensional, multi-item instruments. Cravings for caffeine may manifest and be detected across varying levels of dependence and, frequency of use and independently of duration of abstinence.

  17. Musical instruments of Brazilian capoeira: Historical roots, symbolism, and use

    Science.gov (United States)

    Ilari, Beatriz

    2002-11-01

    This paper describes the historical roots, symbolism, and uses of musical instruments in capoeira. A martial art form of Afro-Brazilian origin, capoeira is rhythmically performed to music in a roda (i.e., circle). Capoeira is at times defined as a martial art form disguised as dance because it is rooted in the struggles of African slaves. Elements of music, dance, fight, and ritual are part of this unique martial art form, which has two main styles: Angola and Regional. Capoeira styles are important as they determine rhythmic patterns, chant, movement, and musical instrumentation in a roda. The leading instrument in all capoeira styles is the berimbau. The instrument dictates the rhythm and movement of capoeira players in a roda (Ilari, 2001). Made out of a wooden stick, a wire, and a gourd and played with a stick and a coin, the berimbau is considered a sacred instrument due to its association with the cry of the slaves. Other instruments used in capoeira are pandeiros, agogo bells, reco-recos, and atabaques. A discussion regarding the use of these instruments within the context of capoeira will be presented at the conference. The incorporation of these instruments into contemporary Brazilian music will also be considered.

  18. The Apprentice to Master Journey: Exploring Tertiary Music Instrument Teachers’ Reflections on Their Experiences as Learner.

    Directory of Open Access Journals (Sweden)

    Ryan Daniel

    2015-03-01

    Full Text Available Many students worldwide engage in lessons on a music instrument; the most common format for this type of learning isthe one-to-one or studio lesson where the master guides the apprentice. At the same time, the one-to-one or studio lesson is an isolated area of practice, given that it takes place behind closed doors. In addition, while the literature for classroom music teachers is substantial with regard to investigating how they describe their own previous teaching experiences or the general characteristics of effective teachers, in comparison there are few studies that explore what music instrument teachers believe are effective characteristics and attributes of their previous teachers and lessons. In order to address this problem, this exploratory article focuses on the reflections of current higher education performing arts teachers; specifically music instrument teachers and their experiences of teachers and lessons. Survey data were obtained from 171 practitioners from nine nations. The respondents were asked to reflect on their initial, pre-tertiary and tertiary lesson experiences and teachers, and to identify the most significant influences on their learning. The data reveal a number of findings, such as the dominance of the master-apprentice social and learning relationship, the characteristics and attributes of inspiring teachers and/or learning experiences, and the fact that some respondents do not have any positive reflections on some periods of their learning.  The data also point towards the cyclical nature of music instrument learning and teaching, with masters guiding apprentices who then become the masters.

  19. Proceedings: Instrumentation and control test reduction workshop

    International Nuclear Information System (INIS)

    1991-09-01

    Instrumentation and control (I ampersand C) surveillance and testing is a significant contributor to operations and management costs. Several techniques to eliminate or reduce manual testing requirements could reduce costs while improving plant safety and performance. I ampersand C test reduction was the subject of this 1991 workshop. The workshop covered test elimination, test reduction, test automation, and relevant standards and benefits. The conclusions of the workshop were the following: More utility information sharing is important. There is a significant amount of information available throughout the industry, but it is not available in a concise, useable form. An I ampersand C utility users group is needed to address items such as instrument calibration reduction, set-point methodologies, and other current I ampersand C issues. The workshop was well received. The timing is right to initiate actions to reduce testing

  20. Assessing Ultraviolet Hazards Using Portable Measuring Instruments

    Energy Technology Data Exchange (ETDEWEB)

    Ridyard, A

    2000-07-01

    The 'Erythemal Action Spectrum' shows an increase of 10{sup 3} in human skin sensitivity to UV radiation over only 30 nm of change of wavelength, from 328 nm to 298 nm. This represents a severe challenge to the manufacturing and calibration of a portable instrument which can measure the vanishingly small amounts of short wavelength UV from solarium tanning lamps, and to apply accurately an action spectra to be able to quantify the hazard presented by such lamps to skin. The classification of UV lamp types from their 'effective irradiance' requires very sharp discrimination between UV power contained in the short wavelength and the long wavelength parts of the UV spectra, so radiometers give misleading results. The only instrument suitable for making these measurements is the spectroradiometer. The development of such an instrument in a hand held portable form is described, with the difficulties associated with its calibration and such factors as stray light rejection. (author)

  1. Assessing Ultraviolet Hazards Using Portable Measuring Instruments

    International Nuclear Information System (INIS)

    Ridyard, A.

    2000-01-01

    The 'Erythemal Action Spectrum' shows an increase of 10 3 in human skin sensitivity to UV radiation over only 30 nm of change of wavelength, from 328 nm to 298 nm. This represents a severe challenge to the manufacturing and calibration of a portable instrument which can measure the vanishingly small amounts of short wavelength UV from solarium tanning lamps, and to apply accurately an action spectra to be able to quantify the hazard presented by such lamps to skin. The classification of UV lamp types from their 'effective irradiance' requires very sharp discrimination between UV power contained in the short wavelength and the long wavelength parts of the UV spectra, so radiometers give misleading results. The only instrument suitable for making these measurements is the spectroradiometer. The development of such an instrument in a hand held portable form is described, with the difficulties associated with its calibration and such factors as stray light rejection. (author)

  2. Vision though afocal instruments: generalized magnification and eye-instrument interaction

    Science.gov (United States)

    Harris, William F.; Evans, Tanya

    2018-04-01

    In Gaussian optics all observers experience the same magnification, the instrument's angular magnification, when viewing distant objects though a telescope or other afocal instruments. However, analysis in linear optics shows that this is not necessarily so in the presence of astigmatism. Because astigmatism may distort and rotate images it is appropriate to work with generalized angular magnification represented by a 2 × 2 matrix. An expression is derived for the generalized magnification for an arbitrary eye looking through an arbitrary afocal instrument. With afocal instruments containing astigmatic refracting elements not all eyes experience the same generalized magnification; there is interaction between eye and instrument. Eye-instrument interaction may change as the instrument is rotated about its longitudinal axis, there being no interaction in particular orientations. A simple numerical example is given. For sake of completeness, expressions for generalized magnification are also presented in the case of instruments that are not afocal and objects that are not distant.

  3. Development and evaluation of the Korean Health Literacy Instrument.

    Science.gov (United States)

    Kang, Soo Jin; Lee, Tae Wha; Paasche-Orlow, Michael K; Kim, Gwang Suk; Won, Hee Kwan

    2014-01-01

    The purpose of this study is to develop and validate the Korean Health Literacy Instrument, which measures the capacity to understand and use health-related information and make informed health decisions in Korean adults. In Phase 1, 33 initial items were generated to measure functional, interactive, and critical health literacy with prose, document, and numeracy tasks. These items included content from health promotion, disease management, and health navigation contexts. Content validity assessment was conducted by an expert panel, and 11 items were excluded. In Phase 2, the 22 remaining items were administered to a convenience sample of 292 adults from community and clinical settings. Exploratory factor and item difficulty and discrimination analyses were conducted and four items with low discrimination were deleted. In Phase 3, the remaining 18 items were administered to a convenience sample of 315 adults 40-64 years of age from community and clinical settings. A confirmatory factor analysis was performed to test the construct validity of the instrument. The Korean Health Literacy Instrument has a range of 0 to 18. The mean score in our validation study was 11.98. The instrument exhibited an internal consistency reliability coefficient of 0.82, and a test-retest reliability of 0.89. The instrument is suitable for screening individuals who have limited health literacy skills. Future studies are needed to further define the psychometric properties and predictive validity of the Korean Health Literacy Instrument.

  4. Intelligent type sodium instrumentations for LMFR

    International Nuclear Information System (INIS)

    Daolong Chen

    1996-01-01

    The constructions and their performances of a lot of newly developed intelligent type sodium instrumentations that consist of the intelligent type sodium flowmeter, the intelligent type immersed sodium flowmeter, the intelligent type sodium manometer and the intelligent type sodium level gauge are described. The graduation characteristic equations for corresponding transducer using the medium temperature as the parameter are given. Because the operating temperature limit of measured medium (sodium) is wide, so the on-line compensation of the temperature effect of their graduation characteristics much be considered. The tests show that these intelligent type sodium instrumentations possess of good linearity. The accurate sodium process parameter (flowrate, pressure and level) measurement data can be obtained by means of their on-line compensation function of the temperature effect. Moreover, these intelligent type sodium instrumentations possess of the self-inspection, the electric shutoff protection, the setting of full-scale, the setting of alarm limits (two upper limits and two lower limits alarms), the thermocouple breaking alarm, each other isolative the 0-10V direct-current analogue output and CENTRONICS standard digital output, and the alarm relay contact output. These intelligent type sodium instrumentations are suitable particularly for the instrument, control and protective systems of LMFR by means of these excellent functions based on microprocessor. The basic error of the intelligent type sodium flowmeter, immersed sodium flowmeter, sodium manometer and sodium level gauge is respectively ±2%, ±2.3%, ±0.3% and ±1.9% of measuring range. (author). 4 refs, 9 figs

  5. Standardization of Nuclear Instrumentation Applied in the NPP and in other nuclear installations

    International Nuclear Information System (INIS)

    Kusnowo, Arlinah; Darmawati, Suzie

    2002-01-01

    Nuclear power plant (NPP) and other nuclear installations have been recognized as applications needing very sophisticated technologies. One of technologies used in this all nuclear facilities is nuclear instrumentation. In order that NPP and other nuclear installations be operated safely, nuclear instrumentation requires standardization from design to its operation. Internationally, standardizations of nuclear instrumentation have been issued by IEC (International Electrotechnical Commission). Formulation of standard in nuclear instrumentation in IEC is carried out by Technical Committee (TC) 45. This paper describes briefly the standardization of nuclear instrumentation applied in Indonesia as Indonesian National Standard (SNI, Standard National Indonesia), standardization of nuclear instrumentation developed by TC 45, SC 45A, and SC 45B, as well as the possibility to adopt and apply those IEC standard in Indonesia

  6. Evaluating a questionnaire to measure improvement initiatives in Swedish healthcare

    Directory of Open Access Journals (Sweden)

    Andersson Ann-Christine

    2013-02-01

    Full Text Available Abstract Background Quality improvement initiatives have expanded recently within the healthcare sector. Studies have shown that less than 40% of these initiatives are successful, indicating the need for an instrument that can measure the progress and results of quality improvement initiatives and answer questions about how quality initiatives are conducted. The aim of the present study was to develop and test an instrument to measure improvement process and outcome in Swedish healthcare. Methods A questionnaire, founded on the Minnesota Innovation Survey (MIS, was developed in several steps. Items were merged and answer alternatives were revised. Employees participating in a county council improvement program received the web-based questionnaire. Data was analysed by descriptive statistics and correlation analysis. The questionnaire psychometric properties were investigated and an exploratory factor analysis was conducted. Results The Swedish Improvement Measurement Questionnaire consists of 27 items. The Improvement Effectiveness Outcome dimension consists of three items and has a Cronbach’s alpha coefficient of 0.67. The Internal Improvement Processes dimension consists of eight sub-dimensions with a total of 24 items. Cronbach’s alpha coefficient for the complete dimension was 0.72. Three significant item correlations were found. A large involvement in the improvement initiative was shown and the majority of the respondents were satisfied with their work. Conclusions The psychometric property tests suggest initial support for the questionnaire to study and evaluate quality improvement initiatives in Swedish healthcare settings. The overall satisfaction with the quality improvement initiative correlates positively to the awareness of individual responsibilities.

  7. Automation of a thermal expansion instrument

    Energy Technology Data Exchange (ETDEWEB)

    Holland, L.L.

    1979-03-01

    Automation of a thermal expansion instrument using a minicomputer system and with analog-to-digital converter inputs and flip-flop relay outputs is described. The necessary hardware link and the software were developed to allow equipment control, data acquisition, data reduction, and report generation by the minicomputer. The design of the automation allows non-programmers to run the experiment, reduce the data, and generate the report.

  8. An Instrument for a Legal Review of Public School Curriculum Policies and Procedures.

    Science.gov (United States)

    Zirkel, Perry A.

    The "Legal Audit Instrument for Public School Curriculum" described in this paper is intended for those making decisions in curricular matters. The instrument has been derived from court decisions that are based on the Federal Constitution, legislation, and regulations. Corresponding cases and provisions within each state will require…

  9. Development and Psychometrics of Instruments to Assess School Personnel's Bystander Action in Situations of Teen Relationship Abuse and Sexual Assault.

    Science.gov (United States)

    Edwards, Katie M; Sessarego, Stephanie N; Stanley, Linda R; Mitchell, Kimberly J; Eckstein, Robert P; Rodenhizer, Kara Anne E; Leyva, P Caroline; Banyard, Victoria L

    2017-12-01

    This article describes recently developed instruments that assess school personnel's bystander barriers and intentions in situations of teen relationship abuse, sexual assault, and sexual harassment, as well as perceptions of school readiness specific to relationship abuse, sexual assault, and sexual harassment prevention and response. Participants were 1,150 high school personnel from 25 schools in New Hampshire, Massachusetts, and Maine. Specific instruments focused on bystander intentions, bystander action, barriers to bystander action, and perceptions of school readiness. Participants were randomly divided into two groups for analysis-the exploratory sample (ES; n = 575) and the confirmatory sample (CS; n = 575). Overall, the measures demonstrated acceptable fit indices. Results suggested that most measures and subscales had adequate reliability, but a few subscales had less than ideal internal consistency, which can likely be attributed to the small number of items. More work is needed, but these measures act as a starting point by which the role of school personnel in prevention initiatives and bystander intervention can be evaluated.

  10. Improved instrumentation for intensity-, wavelength-, temperature-, and magnetic field-resolved photoconductivity spectroscopy

    International Nuclear Information System (INIS)

    Cottingham, Patrick; Morey, Jennifer R.; Lemire, Amanda; Lemire, Penny; McQueen, Tyrel M.

    2016-01-01

    We report instrumentation for photovoltage and photocurrent spectroscopy over a larger continuous range of wavelengths, temperatures, and applied magnetic fields than other instruments described in the literature: 350 nm≤λ≤1700 nm, 1.8 K≤T≤300 K, and B≤9 T. This instrument uses a modulated monochromated incoherent light source with total power<30 μW in combination with an LED in order to probe selected regions of non-linear responses while maintaining low temperatures and avoiding thermal artifacts. The instrument may also be used to measure a related property, the photomagnetoresistance. We demonstrate the importance of normalizing measured responses for variations in light power and describe a rigorous process for performing these normalizations. We discuss several circuits suited to measuring different types of samples and provide analysis for converting measured values into physically relevant properties. Uniform approaches to measurement of these photoproperties are essential for reliable quantitative comparisons between emerging new materials with energy applications. - Highlights: • A novel instrument for measuring photoconductivity and photocurrents of materials and devices. • Continuous parameter space: 350 nm≤λ≤1700, 1.8 K≤T≤300 K, and B≤9 T. • Methodology for treating non-linear responses and variable lamp intensity. • Mathematical detail for extracting properties of materials from measured values is provided.

  11. Improvements and Revamping of In-Core Instrumentation Systems

    International Nuclear Information System (INIS)

    Garam, Eric De

    1993-01-01

    The results of the improvements done by Fumarate Tia in these domains are really satisfying and it is clear that the problems of leakage existing in the old units on the thermocouples sealing systems and on the seal table of the income instrumentation, cannot exist on the French Units or on the units equipped with Fumarate Tia equipment. At the same time, all the equipment which constitute the Income instrumentation have been improved with the aim of reliability and safety. The equipment used to perform maintenance activities has also been improved to both reduce doses and increase efficiency. The purpose of this paper is to describe the principal improvements and revamping of income instrumentation systems, and to summarize the principal lessons learned from our experience on all designs of PWR. Fumarate Tia, is permanently looking for improving the existing systems of instrumentation with the aim of reduction of the dosimetry during the maintenance services, improvement of the liability and lifetime of the equipment, and of course reduction of the duration of the outages in keeping always the same level of quality

  12. Tests of arc-welding-related EMI effects on startup instrumentation

    International Nuclear Information System (INIS)

    Qian, T.; Kalechstein, W.; Cosgrove, D.

    1996-01-01

    The tests described in this paper were conducted to characterize the effects that electromagnetic interference (EMI), from arc welding, has on startup instrumentation (SUI). This paper reviews the results of a literature search on EMI resulting from arc welding and gives the objective and scope of the tests conducted and describes the test equipment and setting, and test procedure and results. Are-welding-related EMI levels in an SUI system were measured to determine the dominant source of interference, the coupling path and the susceptible part of the SUI system. The effectiveness of easily implemented improvements in reducing the level of EMI in the SUI system were also tested. Recommendations are provided on how to eliminate or reduce the EMI effects on sensitive nuclear instruments. (author)

  13. Mars Science Laboratory relative humidity observations: Initial results.

    Science.gov (United States)

    Harri, A-M; Genzer, M; Kemppinen, O; Gomez-Elvira, J; Haberle, R; Polkko, J; Savijärvi, H; Rennó, N; Rodriguez-Manfredi, J A; Schmidt, W; Richardson, M; Siili, T; Paton, M; Torre-Juarez, M De La; Mäkinen, T; Newman, C; Rafkin, S; Mischna, M; Merikallio, S; Haukka, H; Martin-Torres, J; Komu, M; Zorzano, M-P; Peinado, V; Vazquez, L; Urqui, R

    2014-09-01

    The Mars Science Laboratory (MSL) made a successful landing at Gale crater early August 2012. MSL has an environmental instrument package called the Rover Environmental Monitoring Station (REMS) as a part of its scientific payload. REMS comprises instrumentation for the observation of atmospheric pressure, temperature of the air, ground temperature, wind speed and direction, relative humidity (REMS-H), and UV measurements. We concentrate on describing the REMS-H measurement performance and initial observations during the first 100 MSL sols as well as constraining the REMS-H results by comparing them with earlier observations and modeling results. The REMS-H device is based on polymeric capacitive humidity sensors developed by Vaisala Inc., and it makes use of transducer electronics section placed in the vicinity of the three humidity sensor heads. The humidity device is mounted on the REMS boom providing ventilation with the ambient atmosphere through a filter protecting the device from airborne dust. The final relative humidity results appear to be convincing and are aligned with earlier indirect observations of the total atmospheric precipitable water content. The water mixing ratio in the atmospheric surface layer appears to vary between 30 and 75 ppm. When assuming uniform mixing, the precipitable water content of the atmosphere is ranging from a few to six precipitable micrometers. Atmospheric water mixing ratio at Gale crater varies from 30 to 140 ppmMSL relative humidity observation provides good dataHighest detected relative humidity reading during first MSL 100 sols is RH75.

  14. Process instrumentation for nuclear power station

    International Nuclear Information System (INIS)

    Yanai, Katsuya; Shinohara, Katsuhiko

    1978-01-01

    Nuclear power stations are the large scale compound system composed of many process systems. Accordingly, for the safe and high reliability operation of the plants, it is necessary to grasp the conditions of respective processes exactly and control the operation correctly. For this purpose, the process instrumentation undertakes the important function to monitor the plant operation. Hitachi Ltd. has exerted ceaseless efforts since long before to establish the basic technology for the process instrumentation in nuclear power stations, to develop and improve hardwares of high reliability, and to establish the quality control system. As for the features of the process instrumentation in nuclear power stations, the enormous quantity of measurement, the diversity of measured variables, the remote measurement and monitoring method, and the ensuring of high reliability are enumerated. Also the hardwares must withstand earthquakes, loss of coolant accidents, radiations, leaks and fires. Hitachi Unitrol Sigma Series is the measurement system which is suitable to the general process instrumentation in nuclear power stations, and satisfies sufficiently the basic requirements described above. It has various features as the nuclear energy system, such as high reliability by the use of ICs, the methods of calculation and transmission considering signal linkage, loop controller system and small size. HIACS-1000 Series is the analog controller of high reliability for water control. (Kako, I.)

  15. The XGS instrument on-board THESEUS

    International Nuclear Information System (INIS)

    Fuschino, F.; Baldazzi, G.; Rignanese, L. P.; Campana, R.; Labanti, C.; Marisaldi, M.; Amati, L.; Frontera, F.; Fiorini, M.; Uslenghi, M.; Evangelista, Y.; Feroci, M.; Elmi, I.; Rachevski, A.; Zampa, G.; Zampa, N.; Vacchi, A.; Rashevskaya, I.; Bellutti, P.; Piemonte, C.

    2016-01-01

    Consolidated techniques used for space-borne X-ray and gamma-ray instruments are based on the use of scintillators coupled to Silicon photo-detectors. This technology associated with modern very low noise read-out electronics allows the design of innovative architectures able to reduce drastically the system complexity and power consumption, also with a moderate-to-high number of channels. These detector architectures can be exploited in the design of space instrumentation for gamma-spectroscopy with the benefit of possible smart background rejection strategies. We describe a detector prototype with 3D imaging capabilities to be employed in future gamma-ray and particle space missions in the 0.002-100 MeV energy range. The instrument is based on a stack of scintillating bars read out by Silicon Drift Detectors (SDDs) at both ends. The spatial segmentation and the crystal double-side readout allow a 3D position reconstruction with ∼3 mm accuracy within the full active volume, using a 2D readout along the two external faces of the detector. Furthermore, one of the side of SDDs can be used simultaneously to detect X-rays in the 2-30 keV energy range. The characteristics of this instrument make it suitable in next generation gamma-ray and particle space missions for Earth or outer space observations, and it will be briefly illustrated. (paper)

  16. The XGS instrument on-board THESEUS

    Science.gov (United States)

    Fuschino, F.; Campana, R.; Labanti, C.; Marisaldi, M.; Amati, L.; Fiorini, M.; Uslenghi, M.; Baldazzi, G.; Evangelista, Y.; Elmi, I.; Feroci, M.; Frontera, F.; Rachevski, A.; Rignanese, L. P.; Vacchi, A.; Zampa, G.; Zampa, N.; Rashevskaya, I.; Bellutti, P.; Piemonte, C.

    2016-10-01

    Consolidated techniques used for space-borne X-ray and gamma-ray instruments are based on the use of scintillators coupled to Silicon photo-detectors. This technology associated with modern very low noise read-out electronics allows the design of innovative architectures able to reduce drastically the system complexity and power consumption, also with a moderate-to-high number of channels. These detector architectures can be exploited in the design of space instrumentation for gamma-spectroscopy with the benefit of possible smart background rejection strategies. We describe a detector prototype with 3D imaging capabilities to be employed in future gamma-ray and particle space missions in the 0.002-100 MeV energy range. The instrument is based on a stack of scintillating bars read out by Silicon Drift Detectors (SDDs) at both ends. The spatial segmentation and the crystal double-side readout allow a 3D position reconstruction with ∼3 mm accuracy within the full active volume, using a 2D readout along the two external faces of the detector. Furthermore, one of the side of SDDs can be used simultaneously to detect X-rays in the 2-30 keV energy range. The characteristics of this instrument make it suitable in next generation gamma-ray and particle space missions for Earth or outer space observations, and it will be briefly illustrated.

  17. The digital reactor protection system for the instrumentation and control of reactor TRIGA PUSPATI (RTP)

    International Nuclear Information System (INIS)

    Nurfarhana Ayuni Joha; Izhar Abu Hussin; Mohd Idris Taib; Zareen Khan Abdul Jalil Khan

    2010-01-01

    Reactor Protection System (RPS) is important for Reactor Instrumentation and Control System. The RPS comprises all redundant electrical devices and circuitry involved in the generation of those initiating signals associated to the trip protective function. The instrumentation system for the RPS provides automatic protection signals against unsafe and improper reactor operation. The physical separation is provided for all of the redundant instrumentation systems to preserve redundancy. The safety protection systems using circuits composed of analog instruments and relays with relay contacts is difficult to realize from various reasons. Therefore, an application of digital technology can be said a logical conclusion also in the light of its functional superiority. (author)

  18. Fabrication of Non-instrumented capsule for DUPIC simulated fuel irradiation test in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B.G.; Kang, Y.H.; Park, S.J.; Shin, Y.T. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-10-01

    In order to develope DUPIC nuclear fuel, the irradiation test for simulated DUPIC fuel was planed using a non-instrumented capsule in HANARO. Because DUPIC fuel is highly radioactive material the non-instrumented capsule for an irradiation test of simulated DUPIC fuel in HANARO was designed to remotely assemble and disassemble in hot cell. And then, according to the design requirements the non-instrumented DUPIC capsule was successfully manufactured. Also, the manufacturing technologies of the non-instrumented capsule for irradiating the nuclear fuel in HANARO were established, and the basic technology for the development of the instrumented capsule technology was accumulated. This report describes the manufacturing of the non-instrumented capsule for simulated DUPIC fuel. And, this report will be based to develope the instrumented capsule, which will be utilized to irradiate the nuclear fuel in HANARO. 26 refs., 4 figs. (Author)

  19. Assessing Minimum Competencies of Beginning Teachers: Instrumentation, Measurement Issues, Legal Concerns.

    Science.gov (United States)

    Ellett, Chad D.

    An overview is presented of a performance-based assessment system, Teacher Performance Assessment Instruments (TPAI), developed by the Teacher Assessment Project at the University of Georgia to measure competencies of beginning teachers for initial professional certification. To clearly separate the preparation and certification functions within…

  20. Instrumentation for PSD-based neutron diffractometers at Dhruva reactor

    Science.gov (United States)

    Pande, S. S.; Borkar, S. P.; Prafulla, S.; Srivastava, V. D.; Behare, A.; Mukhopadhyay, P. K.; Ghodgaonkar, M. D.; Kataria, S. K.

    2004-08-01

    Linear position sensitive detectors (PSDs) are widely used to configure neutron diffractometers and other instruments. Necessary front-end electronics and a data acquisition system [1] is developed to cater to such instruments built around the Dhruva research reactor in BARC. These include three diffractometers with multiple PSDs and four with single PSD. The front-end electronics consists of high voltage units, preamplifiers [2], shaping amplifiers, ratio ADCs (RDC) [3]. The data acquisition system consists of an interface card and software. Commercially available hardware like temperature controller or stepper motor controller connected over GPIB or RS232 are also integrated in the data acquisition system. The data acquisition is automated so that it can continue unattended for control parameter like temperature, thus enabling optimum utilization of available beam time. The instrumentation is scalable and can be easily configured for various instrumental requirements. The front-end electronics and the data acquisition system are described here.

  1. Transient response of level instruments in a research reactor

    International Nuclear Information System (INIS)

    Cheng, Lap Y.

    1989-01-01

    A numerical model has been developed to simulate the dynamics of water level instruments in a research nuclear reactor. A bubble device, with helium gas as the working fluid, is used to monitor liquid level by sensing the static head pressure due to the height of liquid in the reactor vessel. A finite-difference model is constructed to study the transient response of the water level instruments to pressure perturbations. The field equations which describe the hydraulics of the helium gas in the bubbler device are arranged in the form of a tridiagonal matrix and the field variables are solved at each time step by the Thomas algorithm. Simulation results indicate that the dynamic response of the helium gas depends mainly on the volume and the inertia of the gas in the level instrument tubings. The anomalies in the simulated level indication are attributed to the inherent lag in the level instrument due to the hydraulics of the system. 1 ref., 5 figs

  2. The laser absorption spectrometer - A new remote sensing instrument for atmospheric pollution monitoring

    Science.gov (United States)

    Shumate, M. S.

    1974-01-01

    An instrument capable of remotely monitoring trace atmospheric constituents is described. The instrument, called a laser absorption spectrometer, can be operated from an aircraft or spacecraft to measure the concentration of selected gases in three dimensions. This device will be particularly useful for rapid determination of pollutant levels in urban areas.

  3. Young Learners: An Examination of the Psychometric Properties of the Early Literacy Knowledge and Skills Instrument

    Science.gov (United States)

    Chan, Man Ching Esther

    2015-01-01

    The Early Literacy Knowledge and Skills (ELKS) instrument was informed by the work of Ferreiro and Teberosky based on the notion that young children could be differentiated according to levels of sophistication in their understanding of the rules of written language. As an initial step to evaluate the instrument for teaching purposes, the present…

  4. Master curve based correlation between static initiation toughness KIC and crack arrest toughness KIa

    International Nuclear Information System (INIS)

    Wallin, K.; Rintamaa, R.

    1999-01-01

    Historically the ASME reference curve concept assumes a constant relation between static fracture toughness initiation toughness and crack arrest toughness. In reality, this is not the case. Experimental results show that the difference between K IC and K Ia is material specific. For some materials there is a big difference while for others they nearly coincide. So far, however, no systematic study regarding a possible correlation between the two parameters has been performed. The recent Master curve method, developed for brittle fracture initiation estimation, has enabled a consistent analysis of fracture initiation toughness data. The Master curve method has been modified to be able to describe also crack arrest toughness. Here, this modified 'crack arrest master curve' is further validated and used to develop a simple, but yet (for safety assessment purpose) adequately accurate correlation between the two fracture toughness parameters. The correlation enables the estimation of crack arrest toughness from small Charpy-sized static fracture toughness tests. The correlation is valid for low Nickel steels ≤ (1.2% Ni). If a more accurate description of the crack arrest toughness is required, it can either be measured experimentally or estimated from instrumented Charpy-V crack arrest load information. (orig.)

  5. MANU. Instrumentation of Buffer Demo. Preliminary Study

    International Nuclear Information System (INIS)

    Laaksonen, R.

    2010-01-01

    The purpose of this work is to describe feasible measuring and monitoring alternatives which can be used, if needed, in medium to full scale nuclear waste repository deposition hole mock-up tests. The focus of the work was to determine what variables can actually be measured, how to achieve the measurements and what kind of demands comes from the modelling, scientific, and technical points of view. This project includes a review of the previous waste repository mock-up tests carried out in several European countries such as Belgium, Czech Republic, Spain and Sweden. Also information was gathered by interviewing domestic and foreign scientists specialized in the fields of measurement instrumentation and related in-situ and laboratory work. On the basis of this review, recommendations were developed for the necessary actions needed to be done from the instrumentation point of view for future tests. It is possible to measure and monitor the processes going on in a deposition hole in-situ conditions. The data received during a test in real repository conditions enables to follow the processes and to verify the hypothesis made on the behaviour of various components of the repository: buffer, canister, rock and backfill. Because full scale testing is expensive, the objectives and hypothesis must be carefully set and the test itself with its instrumentation must serve very specific objectives. The main purpose of mock-up tests is to verify that the conditions surrounding the canister are according to the design requirements. A whole mock-up test and demonstration process requires a lot of time and effort. The instrumentation part of the work must also start at early stages to ensure that the instrumentation itself will not become bottlenecked nor suffer from low quality solutions. The planning of the instrumentation work could be done in collaboration with foreign scientists which have participated to previous instrumentation projects. (orig.)

  6. Hubble Space Telescope: Faint object spectrograph instrument handbook. Version 1.1

    Science.gov (United States)

    Ford, Holland C. (Editor)

    1990-01-01

    The Faint Object Spectrograph (FOS) has undergone substantial rework since the 1985 FOS Instrument Handbook was published, and we are now more knowledgeable regarding the spacecraft and instrument operations requirements and constraints. The formal system for observation specification has also evolved considerably, as the GTO programs were defined in detail. This supplement to the FOS Instrument Handbook addresses the important aspects of these changes, to facilitate proper selection and specification of FOS observing programs. Since the Handbook was published, the FOS red detector has been replaced twice, first with the best available spare in 1985 (which proved to have a poor, and steadily degrading red response), and later with a newly developed Digicon, which exhibits a high, stable efficiency and a dark-count rate less than half that of its predecessors. Also, the FOS optical train was realigned in 1987-88 to eliminate considerable beam-vignetting losses, and the collimators were both removed and recoated for greater reflectivity. Following the optics and detector rework, the FOS was carefully recalibrated (although only ambient measurements were possible, so the far-UV characteristics could not be re-evaluated directly). The resulting efficiency curves, including improved estimates of the telescope throughput, are shown. A number of changes in the observing-mode specifications and addition of several optional parameters resulted as the Proposal Instructions were honed during the last year. Target-brightness limitations, which have only recently been formulated carefully, are described. Although these restrictions are very conservative, it is imperative that the detector safety be guarded closely, especially during the initial stages of flight operations. Restrictions on the use of the internal calibration lamps and aperture-illumination sources (TA LEDs), also resulting from detector safety considerations, are outlined. Finally, many changes have been made to

  7. Measuring Environmental Factors: Unique and Overlapping International Classification of Functioning, Disability and Health Coverage of 5 Instruments.

    Science.gov (United States)

    Heinemann, Allen W; Miskovic, Ana; Semik, Patrick; Wong, Alex; Dashner, Jessica; Baum, Carolyn; Magasi, Susan; Hammel, Joy; Tulsky, David S; Garcia, Sofia F; Jerousek, Sara; Lai, Jin-Shei; Carlozzi, Noelle E; Gray, David B

    2016-12-01

    To describe the unique and overlapping content of the newly developed Environmental Factors Item Banks (EFIB) and 7 legacy environmental factor instruments, and to evaluate the EFIB's construct validity by examining associations with legacy instruments. Cross-sectional, observational cohort. Community. A sample of community-dwelling adults with stroke, spinal cord injury, and traumatic brain injury (N=568). None. EFIB covering domains of the built and natural environment; systems, services, and policies; social environment; and access to information and technology; the Craig Hospital Inventory of Environmental Factors (CHIEF) short form; the Facilitators and Barriers Survey/Mobility (FABS/M) short form; the Home and Community Environment Instrument (HACE); the Measure of the Quality of the Environment (MQE) short form; and 3 of the Patient Reported Outcomes Measurement Information System's (PROMIS) Quality of Social Support measures. The EFIB and legacy instruments assess most of the International Classification of Functioning, Disability and Health (ICF) environmental factors chapters, including chapter 1 (products and technology; 75 items corresponding to 11 codes), chapter 2 (natural environment and human-made changes; 31 items corresponding to 7 codes), chapter 3 (support and relationships; 74 items corresponding to 7 codes), chapter 4 (attitudes; 83 items corresponding to 8 codes), and chapter 5 (services, systems, and policies; 72 items corresponding to 16 codes). Construct validity is provided by moderate correlations between EFIB measures and the CHIEF, MQE barriers, HACE technology mobility, FABS/M community built features, and PROMIS item banks and by small correlations with other legacy instruments. Only 5 of the 66 legacy instrument correlation coefficients are moderate, suggesting they measure unique aspects of the environment, whereas all intra-EFIB correlations were at least moderate. The EFIB measures provide a brief and focused assessment of ICF

  8. Pancreatitis Quality of Life Instrument: Development of a new instrument

    Directory of Open Access Journals (Sweden)

    Wahid Wassef

    2014-02-01

    Full Text Available Objectives: The goal of this project was to develop the first disease-specific instrument for the evaluation of quality of life in chronic pancreatitis. Methods: Focus groups and interview sessions were conducted, with chronic pancreatitis patients, to identify items felt to impact quality of life which were subsequently formatted into a paper-and-pencil instrument. This instrument was used to conduct an online survey by an expert panel of pancreatologists to evaluate its content validity. Finally, the modified instrument was presented to patients during precognitive testing interviews to evaluate its clarity and appropriateness. Results: In total, 10 patients were enrolled in the focus groups and interview sessions where they identified 50 items. Once redundant items were removed, the 40 remaining items were made into a paper-and-pencil instrument referred to as the Pancreatitis Quality of Life Instrument. Through the processes of content validation and precognitive testing, the number of items in the instrument was reduced to 24. Conclusions: This marks the development of the first disease-specific instrument to evaluate quality of life in chronic pancreatitis. It includes unique features not found in generic instruments (economic factors, stigma, and spiritual factors. Although this marks a giant step forward, psychometric evaluation is still needed prior to its clinical use.

  9. Instrumentation and Controls Division annual progress report for period ending September 1, 1973

    International Nuclear Information System (INIS)

    Sadowski, G.S.

    1976-08-01

    Research progress is described under the following topics: (1) pulse counting and analysis; (2) support for the thermonuclear division ORMAK project; (3) miscellaneous electronics development; (4) detectors of ionizing particles and radiation; (5) radiation monitoring; (6) support for the Oak Ridge Electron Linear Accelerator; (7) automatic control and data acquisition; (8) process instrumentation and control; (9) reactor instrumentation and controls; (10) instrumentation for reactor division experiments and test loops; (11) maintenance and service; and (12) ecological science studies

  10. A framework for assessing Health Economic Evaluation (HEE) quality appraisal instruments.

    Science.gov (United States)

    Langer, Astrid

    2012-08-16

    Health economic evaluations support the health care decision-making process by providing information on costs and consequences of health interventions. The quality of such studies is assessed by health economic evaluation (HEE) quality appraisal instruments. At present, there is no instrument for measuring and improving the quality of such HEE quality appraisal instruments. Therefore, the objectives of this study are to establish a framework for assessing the quality of HEE quality appraisal instruments to support and improve their quality, and to apply this framework to those HEE quality appraisal instruments which have been subject to more scrutiny than others, in order to test the framework and to demonstrate the shortcomings of existing HEE quality appraisal instruments. To develop the quality assessment framework for HEE quality appraisal instruments, the experiences of using appraisal tools for clinical guidelines are used. Based on a deductive iterative process, clinical guideline appraisal instruments identified through literature search are reviewed, consolidated, and adapted to produce the final quality assessment framework for HEE quality appraisal instruments. The final quality assessment framework for HEE quality appraisal instruments consists of 36 items organized within 7 dimensions, each of which captures a specific domain of quality. Applying the quality assessment framework to four existing HEE quality appraisal instruments, it is found that these four quality appraisal instruments are of variable quality. The framework described in this study should be regarded as a starting point for appraising the quality of HEE quality appraisal instruments. This framework can be used by HEE quality appraisal instrument producers to support and improve the quality and acceptance of existing and future HEE quality appraisal instruments. By applying this framework, users of HEE quality appraisal instruments can become aware of methodological deficiencies

  11. RASOR: an advanced instrument for soft x-ray reflectivity and diffraction.

    Science.gov (United States)

    Beale, T A W; Hase, T P A; Iida, T; Endo, K; Steadman, P; Marshall, A R; Dhesi, S S; van der Laan, G; Hatton, P D

    2010-07-01

    We report the design and construction of a novel soft x-ray diffractometer installed at Diamond Light Source. The beamline endstation RASOR is constructed for general users and designed primarily for the study of single crystal diffraction and thin film reflectivity. The instrument is comprised of a limited three circle (theta, 2theta, and chi) diffractometer with an additional removable rotation (phi) stage. It is equipped with a liquid helium cryostat, and post-scatter polarization analysis. Motorized motions are provided for the precise positioning of the sample onto the diffractometer center of rotation, and for positioning the center of rotation onto the x-ray beam. The functions of the instrument have been tested at Diamond Light Source, and initial test measurements are provided, demonstrating the potential of the instrument.

  12. Nuclear instrumentation cable end seal

    International Nuclear Information System (INIS)

    Cannon, C.P.; Brown, D.P.

    1979-01-01

    An improved coaxial end seal for hermetically sealed nuclear instrumentation cable exhibiting an improved breakdown pulse noise characteristic under high voltage, high temperature conditions is described. A tubular insulator body has metallized interior and exterior surface portions which are braze sealed to a center conductor and an outer conductive sheath. The end surface of the insulator body which is directed toward the coaxial cable to which it is sealed has a recessed surface portion within which the braze seal material terminates

  13. The measurement of inclination on gravity concrete dams using the tiltmeter instrument

    Directory of Open Access Journals (Sweden)

    Radovanović Slobodan D.

    2015-01-01

    Full Text Available The measurement of inclination on gravity concrete dams using the instrument tiltmeter is described and discussed with special reference on obtained results on the dam 'Đerdap 2' acquired in the three years period. Tiltmetar way of operation is presented both through physical principle of vibrating wire sensors and through described design of the instrument. The influence of the temperature on the measurement of the slope is specially emphasized and presented through temperature correction. Processing the results of real inclination measurements on the dam 'Đerdap 2' with and without temperature correction showed the significant difference. Statistical analysis of measurement data consisted of performed regression analysis and forming of corresponding series with the expected measurement values depending on environmental conditions. At the end we give a summary conclusion on the instrument, the influence of temperature on the measurement and statistical model.

  14. Beam instrumentation in the AGS Booster

    International Nuclear Information System (INIS)

    Witkover, R.L.

    1991-01-01

    The AGS Booster was designed to accelerate low intensity (2 x 10 10 ) polarized protons, high intensity (1.5x10 13 ) protons and heavy ions through Au +33 . Coping with this wide range of beams, the 3 x 10 -11 Torr vacuum and the radiation environment presented challenges for the beam monitors. Some of the more interesting instrumentation design and performance during the recent Booster proton commissioning will be described

  15. The Construction of the Malaysian Educators Selection Inventory (MEdSI: A Large Scale Assessment Initiative

    Directory of Open Access Journals (Sweden)

    Joharry Othman

    2008-06-01

    Full Text Available The crucial role that teachers and schools play in the development of a nation’s human resource is undeniable. In Malaysia, teaching has always been perceived as a financially secure and relatively easy job by many, resulting in mass application for entry into teacher education programmes. Many of those who aspire and opto to go into the teaching profession however do so regardless of their personal interests, potential, and values. Pursuing a program that does not fit a person’s personality and interest – despite initially having good academic credentials and excellent co-curricular involvement in school – may result in unsatisfactory academic performance, frustration, change of program and even withdrawal at college level. Hence, in the quest for selecting suitable teacher trainee candidates, a psychometrically sound instrument known as the Malaysian Educators Selection Inventory (MEdSI was developed as a screening measure to filter the large number of teacher hopefuls. This paper specifically describes the theoretical basis and the constructs of the instrument developed.

  16. Statistical pulses generator. Application to nuclear instrumentation (1962); Generateur d'impulsions aleatoires. Application a l'instrumentation nucleaire (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Beranger, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    This report describes a random pulses generator adapted to nuclear instrumentation. After a short survey on the statistical nature of electronic signals, the different ways for generating pulses with a Poisson's time-distribution are studied. The final generator built from a gaseous thyratron in a magnetic field is then described. Several tests are indicated : counting-rate stability, Pearson's criterion, distribution of time-intervals. Applications of the generator in 'whole testing' of nuclear instrumentation are then indicated for sealers, dead time measurements, time analyzers. In this application, pulse-height spectrums have been made by Poissonian sampling of a recurrent or random low-frequency signal. (author) [French] Cette etude decrit un generateur d'impulsions aleatoires et ses applications a l'instrumentation nucleaire. Apres un bref rappel sur la nature statistique des signaux en electronique nucleaire, sont passes en revue les principaux moyens d'obtenir des impulsions distribuees en temps suivant une loi de Poisson. Le generateur utilisant un thyratron a gaz dans un champ magnetique est ensuite decrit; diverses methodes de test sont appliquees (stabilite du taux de comptage, criterium de Pearson, spectre des intervalles ds temps). Les applications du generateur a l'electronique nucleaire dans le domaine des 'essais globaux' sont indiques: test des echelles de comptage et mesure des temps morts, test des analyseurs en temps apres division du taux de comptage par une puissance de deux, test des analyseurs multicanaux en amplitude. Pour cette derniere application, on a realise des spectres d'amplitudes suivant une loi connue, par echantillonnage poissonien d'un signal basse frequence recurrent ou aleatoire. (auteur)

  17. IAEA instrumentation programme keeping pace with technology

    International Nuclear Information System (INIS)

    Fortakov, V.; Rundquist, D.E.

    1995-01-01

    Nuclear components, nuclear practices and nuclear facilities have all improved with the maturing of the industry. These improvements have been driven by forces, which are beyond the normal evolutionary pressures, such as increased safety, as low as possible radiation exposure for the workers as well as for the public and the increasing competiveness of alternative forms of energy generation. International nuclear safeguards has had to keep pace with these technological and administrative changes. Moreover, the political climate has changed since the initial implementation of safeguards under the Non-Proliferation Treaty. Implementation of safeguards agreements has accommodated to these changes as well as to the technical innovations. One important component of safeguards implementation, namely the instruments deployed by inspectors, has matured with the help of Member States. Continued efforts in the development and deployment of appropriate instruments are needed to maintain an acceptable level of efficiency and credibility. (orig.)

  18. The QUIET Instrument

    Energy Technology Data Exchange (ETDEWEB)

    Bischoff, C.; et al.

    2012-07-01

    The Q/U Imaging ExperimenT (QUIET) is designed to measure polarization in the Cosmic Microwave Background, targeting the imprint of inflationary gravitational waves at large angular scales ({approx}1{sup o}). Between 2008 October and 2010 December, two independent receiver arrays were deployed sequentially on a 1.4m side-fed Dragonian telescope. The polarimeters which form the focal planes use a highly compact design based on High Electron Mobility Transistors (HEMTs) that provides simultaneous measurements of the Stokes parameters Q, U, and I in a single module. The 17-element Q-band polarimeter array, with a central frequency of 43.1 GHz, has the best sensitivity (69 {mu}Ks{sup 1/2}) and the lowest instrumental systematic errors ever achieved in this band, contributing to the tensor-to-scalar ratio at r < 0:1. The 84-element W-band polarimeter array has a sensitivity of 87 {mu}Ks{sup 1/2} at a central frequency of 94.5 GHz. It has the lowest systematic errors to date, contributing at r < 0:01. The two arrays together cover multipoles in the range {ell} {approx} 25 -- 975. These are the largest HEMT-based arrays deployed to date. This article describes the design, calibration, performance of, and sources of systematic error for the instrument.

  19. Opto-mechanical design for transmission optics in cryogenic space instrumentation

    Science.gov (United States)

    Kroes, Gabby; Venema, Lars; Navarro, Ramón

    2017-11-01

    NOVA is involved in the development and realization of various optical astronomical instruments for groundbased as well as space telescopes, with a focus on nearand mid-infrared instrumentation. NOVA has developed a suite of scientific instruments with cryogenic optics for the ESO VLT and VLTI instruments: VISIR, MIDI, the SPIFFI 2Kcamera for SINFONI, X-shooter and MATISSE. Other projects include the cryogenic optics for MIRI for the James Webb Space Telescope and several E-ELT instruments. Mounting optics is always a compromise between firmly fixing the optics and preventing stresses within the optics. The fixing should ensure mechanical stability and thus accurate positioning in various gravity orientations, temperature ranges, during launch, transport or earthquake. On the other hand, the fixings can induce deformations and sometimes birefringence in the optics and thus cause optical errors. Even cracking or breaking of the optics is a risk, especially when using brittle infrared optical materials at the cryogenic temperatures required in instruments for infrared astronomy, where differential expansion of various materials amounts easily to several millimeters per meter. Special kinematic mounts are therefore needed to ensure both accurate positioning and low stress. This paper concentrates on the opto-mechanical design of optics mountings, especially for large transmission optics in cryogenic circumstances in space instruments. It describes the development of temperature-invariant ("a-thermal") kinematic designs, their implementation in ground based instrumentation and ways to make them suitable for space instruments.

  20. Conceptualization and measurement of criminal thinking: initial validation of the Criminogenic Thinking Profile.

    Science.gov (United States)

    Mitchell, Damon; Tafrate, Raymond Chip

    2012-10-01

    This article describes two studies concerning the development of a new measure of criminal thinking, the CriminogenicThinking Profile (CTP), influenced by the construct of psychopathy, and traditional models of cognitive-behavioral therapy (CBT). An experimental item pool based on verbalizations from offenders served as the pilot version of the instrument. Principal components analysis of the items resulted in a 62-item, eight-factor scale that was internally consistent. In terms of content, six of the resulting factors were conceptually related to psychopathy, one to CBT, and one to neutralization theory. The factor structure and internal reliability was supported by a subsequent confirmatory factor analysis. Initial support for the CTP's convergent validity was indicated by its positive correlations with psychopathy and personality disorders associated with criminal, aggressive, and impulsive behaviors. The CTP's divergent validity was supported by its inverse correlations with indices of healthy personality functioning. The CTP offers a somewhat different constellation of thinking patterns than those found on previously published criminal thinking instruments. The utility of the CTP to identify relevant cognitive targets for offender treatment is a recommended area of future research.

  1. Modern spinal instrumentation. Part 1: Normal spinal implants

    International Nuclear Information System (INIS)

    Davis, W.; Allouni, A.K.; Mankad, K.; Prezzi, D.; Elias, T.; Rankine, J.; Davagnanam, I.

    2013-01-01

    The general radiologist frequently encounters studies demonstrating spinal instrumentation, either as part of the patient's postoperative evaluation or as incidental to a study performed for another purpose. There are various surgical approaches and devices used in spinal surgery with an increased understanding of spinal and spinal implant biomechanics drives development of modern fixation devices. It is, therefore, important that the radiologist can recognize commonly used devices and identify their potential complications demonstrated on imaging. The aim of part 1 of this review is to familiarize the reader with terms used to describe surgical approaches to the spine, review the function and normal appearances of commonly used instrumentations, and understand the importance of the different fixation techniques. The second part of this review will concentrate on the roles that the different imaging techniques play in assessing the instrumented spine and the recognition of complications that can potentially occur.

  2. Mars 2020 Entry, Descent and Landing Instrumentation (MEDLI2)

    Science.gov (United States)

    Bose, Deepak; Wright, Henry; White, Todd; Schoenenberger, Mark; Santos, Jose; Karlgaard, Chris; Kuhl, Chris; Oishi, TOmo; Trombetta, Dominic

    2016-01-01

    This paper will introduce Mars Entry Descent and Landing Instrumentation (MEDLI2) on NASA's Mars2020 mission. Mars2020 is a flagship NASA mission with science and technology objectives to help answer questions about possibility of life on Mars as well as to demonstrate technologies for future human expedition. Mars2020 is scheduled for launch in 2020. MEDLI2 is a suite of instruments embedded in the heatshield and backshell thermal protection systems of Mars2020 entry vehicle. The objectives of MEDLI2 are to gather critical aerodynamics, aerothermodynamics and TPS performance data during EDL phase of the mission. MEDLI2 builds up the success of MEDLI flight instrumentation on Mars Science Laboratory mission in 2012. MEDLI instrumentation suite measured surface pressure and TPS temperature on the heatshield during MSL entry into Mars. MEDLI data has since been used for unprecedented reconstruction of aerodynamic drag, vehicle attitude, in-situ atmospheric density, aerothermal heating, transition to turbulence, in-depth TPS performance and TPS ablation. [1,2] In addition to validating predictive models, MEDLI data has highlighted extra margin available in the MSL forebody TPS, which can potentially be used to reduce vehicle parasitic mass. MEDLI2 expands the scope of instrumentation by focusing on quantities of interest not addressed in MEDLI suite. The type the sensors are expanded and their layout on the TPS modified to meet these new objectives. The paper will provide key motivation and governing requirements that drive the choice and the implementation of the new sensor suite. The implementation considerations of sensor selection, qualification, and demonstration of minimal risk to the host mission will be described. The additional challenges associated with mechanical accommodation, electrical impact, data storage and retrieval for MEDLI2 system, which extends sensors to backshell will also be described.

  3. Recognition of Instrumentation Gauge in the Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Wan; Jeong, Kyung Min [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Nuclear emergency robots were developed in 2001 as the countermeasure following the criticality accident at the JCO (uranium refinery facility) in Tokaimura, Japan in 1999. We assumed that these nuclear emergency robots were deployed (or put into) for a mitigation (or management) of severe accident, for example, occurred at Fukushima Daiichi nuclear power plant. In the case, the image understanding using a color CCD camera, loaded on the nuclear emergency robot, is important. We proposed an image processing technique to read indication value of the IC water level gauges using the structural characteristics of the instrumentation panels (water level gauges) located inside the reactor building. At first, we recognized the scales on the instrumentation panel using the geometric shape of the panel. And then, we could read the values of the instrumentation gauge by calculating the slope of the needle on the gauge. Using the proposed algorithm, we deciphered instrumentation panels for the four water level gauges and indicators shown on the IC video released by TEPCO and Japanese Nuclear Regulatory Commission of Japan. In this paper, recognition of the instrumentation gauges inside reactor building of the nuclear power plant by an image processing technology is described.

  4. Instrumental neutron activation analysis in environmental studies of trace elements

    International Nuclear Information System (INIS)

    Salmon, L.

    1975-06-01

    The application of a routine instrumental nuclear method is described in relation to environmental surveys and studies. A working rather than formal review is made of the techniques applied with particular reference to the data processing methods involved. The elements measured by instrumental activation analysis were: Ag, Al, As, Au, Ba, Br, Ca, Ce, Cl, Cd, Co, Cr, Cs, Cu, Fe, Hg, I, In, La, Mn, Na, Ni, Pb, Rb, Sb, Sc, Se, Th, Ti, U, V, W, Zn. (author)

  5. Policy instruments to decrease the climate impact of housing, personal transport and food. Detailed instrument descriptions; Ohjauskeinoja asumisen, henkiloeliikenteen ja ruoan ilmastovaikutusten hillintaeaen. Yksityiskohtaiset ohjauskeinokuvaukset

    Energy Technology Data Exchange (ETDEWEB)

    Heiskanen, E.; Perrels, A.; Nissinen, A.; Berghaell, E.; Liesimaa, V.; Mattinen, M. (eds.)

    2012-03-15

    Reducing consumption volumes or introducing climate conscious consumption patterns can be efficient ways to mitigate climate change. Twenty existing policy instruments affecting the greenhouse gas emissions of housing, passenger traffic and food are described in this report of the KUILU-project. The policy instruments and the possibilities to develop effective instrument packages were discussed in two expert workshops, the results of which are presented in annexes of this report. There are already several policy instruments that target on housing and passenger traffic. Their differences in estimated emission reductions are large, which can ease the prioritization and selection of the instruments for further development. So far, only one policy instrument exists that aims to reduce the climate impacts of food choices, namely a Council of State Decision of Principle on Promoting Sustainability in Public Purchasing. However, it includes several measures that can be used to influence private companies and citizens, and thus it opens the field of policy instrument for mitigation of climate impacts of food. According to the expert survey, the most effective policy instrument involved in the analysis was building regulations, and the four most effective instruments after this were the following: gradated procurement tax of cars based on emissions, gradation of car tax, taxation of transport fuels, energy taxes of housing, and the effect of ecodesign directive on appliances. The effectiveness of policy instruments related to food was assessed to be on average level. The five least effective instruments were: EU energy label, voluntary energy experts, the tax of beverage packing, energy certificates, and subsidies for energy efficiency reparation in buildings. However, the expert opinions on the effectiveness of the policy instruments varied significantly. After this report, the KUILU project continued with an analysis of the policy instrument packages and with suggestions

  6. Policy instruments to decrease the climate impact of housing, personal transport and food. Detailed instrument descriptions; Ohjauskeinoja asumisen, henkiloeliikenteen ja ruoan ilmastovaikutusten hillintaeaen. Yksityiskohtaiset ohjauskeinokuvaukset

    Energy Technology Data Exchange (ETDEWEB)

    Heiskanen, E.; Perrels, A.; Nissinen, A.; Berghaell, E.; Liesmaa, V.; Mattinen, M. (eds.)

    2012-07-01

    Reducing consumption volumes or introducing climate conscious consumption patterns can be efficient ways to mitigate climate change. Twenty existing policy instruments affecting the greenhouse gas emissions of housing, passenger traffic and food are described in this report of the KUILU-project. The policy instruments and the possibilities to develop effective instrument packages were discussed in two expert workshops, the results of which are presented in annexes of this report. There are already several policy instruments that target on housing and passenger traffic. Their differences in estimated emission reductions are large, which can ease the prioritization and selection of the instruments for further development. So far, only one policy instrument exists that aims to reduce the climate impacts of food choices, namely a Council of State Decision of Principle on Promoting Sustainability in Public Purchasing. However, it includes several measures that can be used to influence private companies and citizens, and thus it opens the field of policy instrument for mitigation of climate impacts of food. According to the expert survey, the most effective policy instrument involved in the analysis was building regulations, and the four most effective instruments after this were the following: gradated procurement tax of cars based on emissions, gradation of car tax, taxation of transport fuels, energy taxes of housing, and the effect of ecodesign directive on appliances. The effectiveness of policy instruments related to food was assessed to be on average level. The five least effective instruments were: EU energy label, voluntary energy experts, the tax of beverage packing, energy certificates, and subsidies for energy efficiency reparation in buildings. However, the expert opinions on the effectiveness of the policy instruments varied significantly. After this report, the KUILU project continued with an analysis of the policy instrument packages and with suggestions

  7. Rational Choice of the Investment Project Using Interval Estimates of the Initial Parameters

    Directory of Open Access Journals (Sweden)

    Kotsyuba Oleksiy S.

    2016-11-01

    Full Text Available The article is dedicated to the development of instruments to support decision-making on the problem of choosing the best investment project in a situation when initial quantitative parameters of the considered investment alternatives are described by interval estimates. In terms of managing the risk caused by interval uncertainty of the initial data, the study is limited to the component (aspect of risk measure as a degree of possibility of discrepancy between the resulting economic indicator (criterion and its normative level (the norm. An important hypothesis used as a basis for the proposed in the work formalization of the problem under consideration is the presence – for some or all of the projects from which the choice is made – of risk of poor rate of return in terms of net present (current value. Based upon relevant developments within the framework of the fuzzy-set methodology and interval analysis, there formulated a model for choosing an optimal investment project from the set of alternative options for the interval formulation of the problem. In this case it is assumed that indicators of economic attractiveness (performance of the compared directions of real investment are described either by interval estimates or possibility distribution functions. With the help of the estimated conditional example there implemented an approbation of the proposed model, which demonstrated its practical viability.

  8. Periodontal instrumentation for the general dental practitioner: Pt. 2. Management maintenance and sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Touyz, L.Z.G. (University of the Witwatersrand, Johannesburg (South Africa). Dept. of Oral Medicine and Periodontology); De Waal, J.

    1983-03-01

    The purpose of this article is to describe the management, maintenance and sterilization of periodontal instrumentation used by the general dental practitioner. The pre-sterilization, decontamination and cleaning, the sharpening of instrumentation and the packaging, identification and grouping for sterilization are discussed. Attention is also given to various techniques of sterilization, including gamma radiation.

  9. DEVELOPMENT OF AN ON-LINE, REAL-TIME ALPHA RADIATION MEASURING INSTRUMENT FOR LIQUID STREAMS

    International Nuclear Information System (INIS)

    Unknown

    1999-01-01

    Thermo Power Corporation has proven the technical viability of an on-line, real-time alpha radionuclide instrument for aqueous sample analysis through laboratory and initial field tests of the instrument. The instrument has been shown to be isotonically sensitive to extremely low (ten parts per trillion, or femto Curies per liter) levels of a broad range of radioisotopes. Performance enhancement and other scaling data obtained during the course of this investigation have shown that on-line, real-time operation is possible, with a sub 30-minute response time analyzing 20 ppb (30 pCi/1) natural uranium. Now that these initial field tests in Oak Ridge, Tennessee have been successfully completed, Thermo Power plans to conduct comprehensive field tests of the instrument. The purpose of these endurance tests will be to determine the endurance characteristics of the Thermo Alpha Monitor for Water when it is used by non-Thermo Power personnel in a series of one or more extended field tests. Such endurance testing is the vital next step towards the commercialization of the Alpha Monitor. Subsequently, it will be possible to provide the DOE with an instrument that has the capability of obtaining rapid feedback about the concentrations of alpha-emitting isotope contamination in effluent water streams (Subsurface Contaminants Focus Area). It will also be useful for process control of remediation and D and D operations such as monitoring scrubber/rinse water radioactivity levels (Mixed Waste, Plutonium and D and D Focus Areas)

  10. Evolution of Instrumentation for UV-Visible Spectrophotometry. Part I.

    Science.gov (United States)

    Altemose, Ines R.

    1986-01-01

    Traces the development of instruments used in spectrophotometry. Discusses how spectrophotometric measurements are made. Describes the color comparator, the filter photometer, and the spectrophotometer. Outlines the evolution of optical systems, including light sources, the monochromator, the photodetector, double-beam optics, and split-beam…

  11. Absolute measurement of LDR brachytherapy source emitted power: Instrument design and initial measurements.

    Science.gov (United States)

    Malin, Martha J; Palmer, Benjamin R; DeWerd, Larry A

    2016-02-01

    Energy-based source strength metrics may find use with model-based dose calculation algorithms, but no instruments exist that can measure the energy emitted from low-dose rate (LDR) sources. This work developed a calorimetric technique for measuring the power emitted from encapsulated low-dose rate, photon-emitting brachytherapy sources. This quantity is called emitted power (EP). The measurement methodology, instrument design and performance, and EP measurements made with the calorimeter are presented in this work. A calorimeter operating with a liquid helium thermal sink was developed to measure EP from LDR brachytherapy sources. The calorimeter employed an electrical substitution technique to determine the power emitted from the source. The calorimeter's performance and thermal system were characterized. EP measurements were made using four (125)I sources with air-kerma strengths ranging from 2.3 to 5.6 U and corresponding EPs of 0.39-0.79 μW, respectively. Three Best Medical 2301 sources and one Oncura 6711 source were measured. EP was also computed by converting measured air-kerma strengths to EPs through Monte Carlo-derived conversion factors. The measured EP and derived EPs were compared to determine the accuracy of the calorimeter measurement technique. The calorimeter had a noise floor of 1-3 nW and a repeatability of 30-60 nW. The calorimeter was stable to within 5 nW over a 12 h measurement window. All measured values agreed with derived EPs to within 10%, with three of the four sources agreeing to within 4%. Calorimeter measurements had uncertainties ranging from 2.6% to 4.5% at the k = 1 level. The values of the derived EPs had uncertainties ranging from 2.9% to 3.6% at the k = 1 level. A calorimeter capable of measuring the EP from LDR sources has been developed and validated for (125)I sources with EPs between 0.43 and 0.79 μW.

  12. VINCI: the VLT Interferometer commissioning instrument

    Science.gov (United States)

    Kervella, Pierre; Coudé du Foresto, Vincent; Glindemann, Andreas; Hofmann, Reiner

    2000-07-01

    The Very Large Telescope Interferometer (VLTI) is a complex system, made of a large number of separated elements. To prepare an early successful operation, it will require a period of extensive testing and verification to ensure that the many devices involved work properly together, and can produce meaningful data. This paper describes the concept chosen for the VLTI commissioning instrument, LEONARDO da VINCI, and details its functionalities. It is a fiber based two-way beam combiner, associated with an artificial star and an alignment verification unit. The technical commissioning of the VLTI is foreseen as a stepwise process: fringes will first be obtained with the commissioning instrument in an autonomous mode (no other parts of the VLTI involved); then the VLTI telescopes and optical trains will be tested in autocollimation; finally fringes will be observed on the sky.

  13. Remote sensing optical instrumentation for enhanced space weather monitoring from the L1 and L5 Lagrange points

    Science.gov (United States)

    Kraft, S.; Puschmann, K. G.; Luntama, J. P.

    2017-09-01

    As part of the Space Situational Awareness Programme (SSA), ESA has initiated the assessment of two missions currently foreseen to be implemented to enable enhanced space weather monitoring. These missions utilize the positioning of satellites at the Lagrangian L1 and L5 points. These Phase 0 or Pre-Phase A mission studies are about to be completed and will thereby have soon passed the Mission Definition Review. Phase A studies are planned to start in 2017. The space weather monitoring system currently considers four remote sensing optical instruments and several in-situ instruments to analyse the Sun and the solar wind conditions, in order to provide early warnings of increased solar activity and to identify and mitigate potential threats to society and ground, airborne and space based infrastructure. The suggested optical instruments take heritage from ESA and NASA science missions like SOHO, STEREO and Solar Orbiter, but the instruments are foreseen to be optimized for operational space weather monitoring purposes with high reliability and robustness demands. The instruments are required to provide high quality measurements particularly during severe space weather events. The program intends to utilize the results of the on-going ESA instrument prototyping and technology development activities, and to initiate pre-developments of the operational space weather instruments to ensure the required maturity before the mission implementation.

  14. Instrumental Neutron Activation Analysis and Multivariate Statistics for Pottery Provenance

    Science.gov (United States)

    Glascock, M. D.; Neff, H.; Vaughn, K. J.

    2004-06-01

    The application of instrumental neutron activation analysis and multivariate statistics to archaeological studies of ceramics and clays is described. A small pottery data set from the Nasca culture in southern Peru is presented for illustration.

  15. Instrumental Neutron Activation Analysis and Multivariate Statistics for Pottery Provenance

    International Nuclear Information System (INIS)

    Glascock, M. D.; Neff, H.; Vaughn, K. J.

    2004-01-01

    The application of instrumental neutron activation analysis and multivariate statistics to archaeological studies of ceramics and clays is described. A small pottery data set from the Nasca culture in southern Peru is presented for illustration.

  16. Instrumental Neutron Activation Analysis and Multivariate Statistics for Pottery Provenance

    Energy Technology Data Exchange (ETDEWEB)

    Glascock, M. D.; Neff, H. [University of Missouri, Research Reactor Center (United States); Vaughn, K. J. [Pacific Lutheran University, Department of Anthropology (United States)

    2004-06-15

    The application of instrumental neutron activation analysis and multivariate statistics to archaeological studies of ceramics and clays is described. A small pottery data set from the Nasca culture in southern Peru is presented for illustration.

  17. Instrument workstation for the EGSE of the Near Infrared Spectro-Photometer instrument (NISP) of the EUCLID mission

    Science.gov (United States)

    Trifoglio, M.; Gianotti, F.; Conforti, V.; Franceschi, E.; Stephen, J. B.; Bulgarelli, A.; Fioretti, V.; Maiorano, E.; Nicastro, L.; Valenziano, L.; Zoli, A.; Auricchio, N.; Balestra, A.; Bonino, D.; Bonoli, C.; Bortoletto, F.; Capobianco, V.; Chiarusi, T.; Corcione, L.; Debei, S.; De Rosa, A.; Dusini, S.; Fornari, F.; Giacomini, F.; Guizzo, G. P.; Ligori, S.; Margiotta, A.; Mauri, N.; Medinaceli, E.; Morgante, G.; Patrizii, L.; Sirignano, C.; Sirri, G.; Sortino, F.; Stanco, L.; Tenti, M.

    2016-07-01

    The NISP instrument on board the Euclid ESA mission will be developed and tested at different levels of integration using various test equipment which shall be designed and procured through a collaborative and coordinated effort. The NISP Instrument Workstation (NI-IWS) will be part of the EGSE configuration that will support the NISP AIV/AIT activities from the NISP Warm Electronics level up to the launch of Euclid. One workstation is required for the NISP EQM/AVM, and a second one for the NISP FM. Each workstation will follow the respective NISP model after delivery to ESA for Payload and Satellite AIV/AIT and launch. At these levels the NI-IWS shall be configured as part of the Payload EGSE, the System EGSE, and the Launch EGSE, respectively. After launch, the NI-IWS will be also re-used in the Euclid Ground Segment in order to support the Commissioning and Performance Verification (CPV) phase, and for troubleshooting purposes during the operational phase. The NI-IWS is mainly aimed at the local storage in a suitable format of the NISP instrument data and metadata, at local retrieval, processing and display of the stored data for on-line instrument assessment, and at the remote retrieval of the stored data for off-line analysis on other computers. We describe the design of the IWS software that will create a suitable interface to the external systems in each of the various configurations envisaged at the different levels, and provide the capabilities required to monitor and verify the instrument functionalities and performance throughout all phases of the NISP lifetime.

  18. The challenges of developing an instrument to assess health provider motivation at primary care level in rural Burkina Faso, Ghana, and Tanzania

    Directory of Open Access Journals (Sweden)

    Helen Prytherch

    2012-10-01

    Full Text Available Background: The quality of health care depends on the competence and motivation of the health workers that provide it. In the West, several tools exist to measure worker motivation, and some have been applied to the health sector. However, none have been validated for use in sub-Saharan Africa. The complexity of such tools has also led to concerns about their application at primary care level. Objective: To develop a common instrument to monitor any changes in maternal and neonatal health (MNH care provider motivation resulting from the introduction of pilot interventions in rural, primary level facilities in Ghana, Burkina Faso, and Tanzania. Design: Initially, a conceptual framework was developed. Based upon this, a literature review and preliminary qualitative research, an English-language instrument was developed and validated in an iterative process with experts from the three countries involved. The instrument was then piloted in Ghana. Reliability testing and exploratory factor analysis were used to produce a final, parsimonious version. Results and discussion: This paper describes the actual process of developing the instrument. Consequently, the concepts and items that did not perform well psychometrically at pre-test are first presented and discussed. The final version of the instrument, which comprises 42 items for self-assessment and eight for peer-assessment, is then shown. This is followed by a presentation and discussion of the findings from first use of the instrument with MNH providers from 12 rural, primary level facilities in each of the three countries. Conclusions: It is possible to undertake work of this nature at primary health care level, particularly if the instruments are kept as straightforward as possible and well introduced. However, their development requires very lengthy preparatory periods. The effort needed to adapt such instruments for use in different countries within the region of sub-Saharan Africa should not

  19. The challenges of developing an instrument to assess health provider motivation at primary care level in rural Burkina Faso, Ghana and Tanzania

    Science.gov (United States)

    Prytherch, Helen; Leshabari, Melkidezek T.; Wiskow, Christiane; Aninanya, Gifty A.; Kakoko, Deodatus C.V.; Kagoné, Moubassira; Burghardt, Juliane; Kynast-Wolf, Gisela; Marx, Michael; Sauerborn, Rainer

    2012-01-01

    Background The quality of health care depends on the competence and motivation of the health workers that provide it. In the West, several tools exist to measure worker motivation, and some have been applied to the health sector. However, none have been validated for use in sub-Saharan Africa. The complexity of such tools has also led to concerns about their application at primary care level. Objective To develop a common instrument to monitor any changes in maternal and neonatal health (MNH) care provider motivation resulting from the introduction of pilot interventions in rural, primary level facilities in Ghana, Burkina Faso, and Tanzania. Design Initially, a conceptual framework was developed. Based upon this, a literature review and preliminary qualitative research, an English-language instrument was developed and validated in an iterative process with experts from the three countries involved. The instrument was then piloted in Ghana. Reliability testing and exploratory factor analysis were used to produce a final, parsimonious version. Results and discussion This paper describes the actual process of developing the instrument. Consequently, the concepts and items that did not perform well psychometrically at pre-test are first presented and discussed. The final version of the instrument, which comprises 42 items for self-assessment and eight for peer-assessment, is then shown. This is followed by a presentation and discussion of the findings from first use of the instrument with MNH providers from 12 rural, primary level facilities in each of the three countries. Conclusions It is possible to undertake work of this nature at primary health care level, particularly if the instruments are kept as straightforward as possible and well introduced. However, their development requires very lengthy preparatory periods. The effort needed to adapt such instruments for use in different countries within the region of sub-Saharan Africa should not be underestimated. PMID

  20. On-line calibration of process instrumentation channels in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hashemian, H.M.; Farmer, J.P. [Analysis and Measurement Services Corp., Knoxville, TN (United States)

    1995-04-01

    An on-line instrumentation monitoring system was developed and validated for use in nuclear power plants. This system continuously monitors the calibration status of instrument channels and determines whether or not they require manual calibrations. This is accomplished by comparing the output of each instrument channel to an estimate of the process it is monitoring. If the deviation of the instrument channel from the process estimate is greater than an allowable limit, then the instrument is said to be {open_quotes}out of calibration{close_quotes} and manual adjustments are made to correct the calibration. The success of the on-line monitoring system depends on the accuracy of the process estimation. The system described in this paper incorporates both simple intercomparison techniques as well as analytical approaches in the form of data-driven empirical modeling to estimate the process. On-line testing of the calibration of process instrumentation channels will reduce the number of manual calibrations currently performed, thereby reducing both costs to utilities and radiation exposure to plant personnel.

  1. A Novel Method Describing the Space Charge Limited Region in a Planar Diode

    Directory of Open Access Journals (Sweden)

    Mitra Ghergherehchi

    2017-11-01

    Full Text Available A novel and rather simple method is presented to describe the physics of space-charge region in a planar diode. The method deals with the issue in the time domain and as a consequence transient time behavior can be achieved. Potential distributions and currents obtained using this technique, supposing zero initial velocity for electrons, reveal absolute agreement with Child's results. Moreover, applying the method for non-zero uniform initial velocity for electrons, gives results which are in good agreement with previous works

  2. X-ray powder crystallography with vertex instrumentation

    International Nuclear Information System (INIS)

    Chatzisotiriou, V.; Christofis, I.; Dimitriou, N.; Karvelas, S.; Karydas, A.G.; Loukas, D.; Pavlidis, A.; Spirou, S.; Dre, C.; Haralabidis, N.; Misiakos, K.; Tsoi, E.; Perdikatsis, V.; Psycharis, V.; Terzis, A.; Turchetta, R.

    1998-01-01

    An X-ray Diffractometer for Powder Crystallography is described along with experimental results and future plans. This is an intermediate instrument toward a long linear array system. Three channels of a silicon microstrip detector, are the detecting elements in the present instrument. Each detector channel is followed by a VLSI readout chain, which consists of a charge preamplifier with pulse shaping circuitry, a discriminator, and a 16-bit counter. Control and data acquisition is performed with a custom made PC readout card. A motorized goniometer scans the angle range of interest. Calibration of the system is done with reference samples and data which are captured with a one-channel conventional NaI detector. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  3. Cardiac 82rubidium PET/CT: initial European experience

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Dickson, John C.; Kayani, Irfan; Endozo, Raymondo; Blanchard, Patty; Shastry, Manu; Prvulovich, Elizabeth; Waddington, Wendy A.; Ben-Haim, Simona; Bomanji, Jamshed B.; Ell, Peter J.; Speechly-Dick, Marie-Elsya; McEwan, Jean R.

    2007-01-01

    Myocardial perfusion with PET/CT has advantages over conventional SPECT. We describe our initial European experience using 82 Rubidium-PET/CT, as part of a clinical myocardial perfusion service. We studied the first 100 patients (64 male; 36 female, mean age = 60: SD +/-12.5y, mean body mass index = 30: SD +/-6.9kg/m 2 ) who underwent 82 Rubidium cardiac PET/CT in our institution. Thirty patients had recently undergone coronary angiography. Patients underwent imaging during adenosine infusion and at rest. Images were acquired over 5 minutes using a GE-PET/CT instrument. Image quality was described as good, adequate or inadequate. Images were reported patient-by-patient by a minimum of five nuclear medicine physicians. A segment-by-segment analysis (17-segment model) was also performed. Image quality was good in 77%, adequate 23% and inadequate 0%. There was no statistical difference in image quality between obese and non-obese patients (Fisher's exact test, p = 0.2864). 59% had normal perfusion studies, 29% had inducible ischaemia, 12% had myocardial infarction (11% with super added ischaemia). There was reduced 82 Rubidium uptake in 132/1700 segments during stress. There was reduced 82 Rubidium uptake at rest in 42/1700 segments. The 82 Rubidium PET/CT findings were consistent with the angiographic findings in 28/30 cases. We show that, even from initial use of 82 Rubidium, it is possible to perform myocardial perfusion studies quickly with good image quality, even in the obese. The PET findings correlated well in the third of the cases where angiography was available. As such, 82 Rubidium cardiac PET/CT is likely to be an exciting addition to the European nuclear physician/ cardiologist's radionuclide imaging arsenal. (orig.)

  4. Frequency-Zooming ARMA Modeling for Analysis of Noisy String Instrument Tones

    Directory of Open Access Journals (Sweden)

    Paulo A. A. Esquef

    2003-09-01

    Full Text Available This paper addresses model-based analysis of string instrument sounds. In particular, it reviews the application of autoregressive (AR modeling to sound analysis/synthesis purposes. Moreover, a frequency-zooming autoregressive moving average (FZ-ARMA modeling scheme is described. The performance of the FZ-ARMA method on modeling the modal behavior of isolated groups of resonance frequencies is evaluated for both synthetic and real string instrument tones immersed in background noise. We demonstrate that the FZ-ARMA modeling is a robust tool to estimate the decay time and frequency of partials of noisy tones. Finally, we discuss the use of the method in synthesis of string instrument sounds.

  5. Nuclear instrumentation system operating experience and nuclear instrument testing in the EBR-II

    International Nuclear Information System (INIS)

    Yingling, G.E.; Curran, R.N.

    1980-01-01

    In March of 1972 three wide range nuclear channels were purchased from Gulf Atomics Corporation and installed in EBR-II as a test. The three channels were operated as a test until April 1975 when they became a permanent part of the reactor shutdown system. Also described are the activities involved in evaluating and qualifying neutron detectors for LMFBR applications. Included are descriptions of the ANL Components Technology Division Test Program and the EBR-II Nuclear Instrument Test Facilities (NITF) used for the in-reactor testing and a summary of program test results from EBR-II

  6. Information barriers in the trilateral initiative: Conceptual description

    International Nuclear Information System (INIS)

    Whiteson, R.; MacArthur, D.W.

    1998-01-01

    In this paper the authors attempt to define the structure and requirements (both in hardware and software) of an information barrier (IB) for the trilateral initiative. This IB concept will be employed in the radiation measurement instrument(s) used for attribute verification of excess fissile materials offered for international safeguarding. In this paper, they will specifically not attempt to present a list of solutions to the problems, but instead, concentrate on generating a thorough discussion of the goals and problems themselves. In some cases they have presented potential solutions; these discussions are meant as illustrations of the types of systems required and are not intended as endorsements of any particular solution

  7. Design of nuclear instruments for industrial use

    International Nuclear Information System (INIS)

    Maggio, G.E.

    1988-01-01

    Following an introduction to the atomic structure and the radioactive desintegration, the applications of radioisotopic sealed sources are described. The laws that govern the interaction of radiation with matter and the statistics applied to the radioactive measurements are presented. Different measurement techniques, basic equations of design, the way to provide the activity calculation of a source and the detector's characteristics are given, according to the parameters to be measured and the conditions imposed. Finally, the principles of operation and the most important characteristics of different nuclear instruments to be used in industrial measurements are described. (Author) [es

  8. SMAP Instrument Mechanical System Engineering

    Science.gov (United States)

    Slimko, Eric; French, Richard; Riggs, Benjamin

    2013-01-01

    The Soil Moisture Active Passive (SMAP) mission, scheduled for launch by the end of 2014, is being developed to measure the soil moisture and soil freeze/thaw state on a global scale over a three-year period. The accuracy, resolution, and global coverage of SMAP measurements are invaluable across many science and applications disciplines including hydrology, climate, carbon cycle, and the meteorological, environment, and ecology applications communities. The SMAP observatory is composed of a despun bus and a spinning instrument platform that includes both a deployable 6 meter aperture low structural frequency Astromesh reflector and a spin control system. The instrument section has engendered challenging mechanical system issues associated with the antenna deployment, flexible antenna pointing in the context of a multitude of disturbances, spun section mass properties, spin control system development, and overall integration with the flight system on both mechanical and control system levels. Moreover, the multitude of organizations involved, including two major vendors providing the spin subsystem and reflector boom assembly plus the flight system mechanical and guidance, navigation, and control teams, has led to several unique system engineering challenges. Capturing the key physics associated with the function of the flight system has been challenging due to the many different domains that are applicable. Key interfaces and operational concepts have led to complex negotiations because of the large number of organizations that integrate with the instrument mechanical system. Additionally, the verification and validation concerns associated with the mechanical system have had required far-reaching involvement from both the flight system and other subsystems. The SMAP instrument mechanical systems engineering issues and their solutions are described in this paper.

  9. Application of Peleg's equation to describe creep responses of potatoes under constant and variable storage conditions.

    Science.gov (United States)

    Solomon, W K; Jindal, V K

    2017-06-01

    The application of Peleg's equation to characterize creep behavior of potatoes during storage was investigated. Potatoes were stored at 25, 15, 5C, and variable (fluctuating) temperature for 16 or 26 weeks. The Peleg equation adequately described the creep response of potatoes during storage at all storage conditions (R 2  = .97to .99). Peleg constant k 1 exhibited a significant (p creep responses during storage or processing will be potentially helpful to better understand the phenomenon. The model parameters from such model could be used to relate rheological properties of raw and cooked potatoes. Moreover, the model parameters could be used to establish relationship between instrumental and sensory attributes which will help in the prediction of sensory attributes from instrumental data. © 2016 Wiley Periodicals, Inc.

  10. The KNK II instrumentation for global and local supervision of the reactor core

    International Nuclear Information System (INIS)

    Steiger, W.O.

    1990-01-01

    After an introduction into the KNK plant itself, their historical development and their present situation, the instrumentation of the global and local supervision of the KNK II-core as well as the main safety-related i- and c-systems are described. Special emphasis is laid on the instrumentation of the reactor protection systems and the shutdown systems. After that some practices are reported about instrumentation behavior and lessons learned from the operation and maintenance of the above mentioned systems. At last follows a short description of the special instrumentation for the detection of failed fuel subassemblies and of the plant data processing system. (orig.)

  11. Design of software platform based on linux operating system for γ-spectrometry instrument

    International Nuclear Information System (INIS)

    Hong Tianqi; Zhou Chen; Zhang Yongjin

    2008-01-01

    This paper described the design of γ-spectrometry instrument software platform based on s3c2410a processor with arm920t core, emphases are focused on analyzing the integrated application of embedded linux operating system, yaffs file system and qt/embedded GUI development library. It presented a new software platform in portable instrument for γ measurement. (authors)

  12. Multifamily Hubs' Initial Endorsements FY12

    Data.gov (United States)

    Department of Housing and Urban Development — Describes the program, geographic & lender distribution of multifamily loans initially endorsed for FHA insurance or risk sharing in FY 12. A loan is initially...

  13. Thermal architecture of the SPICA/SAFARI instrument

    Science.gov (United States)

    Charles, Ivan; Duband, Lionel; Duval, Jean-Marc; Jackson, Brian; Jellema, Willem; Kooijman, Peter Paul; Luchier, Nicolas; Tirolien, Thierry; van Weers, Henk

    2012-09-01

    The SAFARI instrument is a far infrared imaging spectrometer that is a core instrument of the SPICA mission. Thanks to the large (3 meter) SPICA cold telescope, the ultra sensitive detectors and a powerful Fourier Transform Spectrometer, this instrument will give access to the faintest light never observed in the 34 μm - 210 μm bandwidth with a high spectral resolution. To achieve this goal, TES detectors, that need to be cooled at a temperature as low as 50 mK, have been chosen. The thermal architecture of the SAFARI focal plane unit (FPU) which fulfils the TES detector thermal requirements is presented. In particular, an original 50 mK cooler concept based on a sorption cooler in series with an adiabatic demagnetization refrigerator will be used. The thermal design of the detector focal plane array (FPA) that uses three temperature stages to limit the loads on the lowest temperature stage, will be also described. The current SAFARI thermal budget estimations are presented and discussed regarding the limited SPICA allocations. Finally, preliminary thermal sensitivity analysis dealing with thermal stability requirements is presented.

  14. Instrument performance evaluation

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1993-03-01

    Deficiencies exist in both the performance and the quality of health physics instruments. Recognizing the implications of such deficiencies for the protection of workers and the public, in the early 1980s the DOE and the NRC encouraged the development of a performance standard and established a program to test a series of instruments against criteria in the standard. The purpose of the testing was to establish the practicality of the criteria in the standard, to determine the performance of a cross section of available instruments, and to establish a testing capability. Over 100 instruments were tested, resulting in a practical standard and an understanding of the deficiencies in available instruments. In parallel with the instrument testing, a value-impact study clearly established the benefits of implementing a formal testing program. An ad hoc committee also met several times to establish recommendations for the voluntary implementation of a testing program based on the studies and the performance standard. For several reasons, a formal program did not materialize. Ongoing tests and studies have supported the development of specific instruments and have helped specific clients understand the performance of their instruments. The purpose of this presentation is to trace the history of instrument testing to date and suggest the benefits of a centralized formal program

  15. Optical modeling of waveguide coupled TES detectors towards the SAFARI instrument for SPICA

    Science.gov (United States)

    Trappe, N.; Bracken, C.; Doherty, S.; Gao, J. R.; Glowacka, D.; Goldie, D.; Griffin, D.; Hijmering, R.; Jackson, B.; Khosropanah, P.; Mauskopf, P.; Morozov, D.; Murphy, A.; O'Sullivan, C.; Ridder, M.; Withington, S.

    2012-09-01

    The next generation of space missions targeting far-infrared wavelengths will require large-format arrays of extremely sensitive detectors. The development of Transition Edge Sensor (TES) array technology is being developed for future Far-Infrared (FIR) space applications such as the SAFARI instrument for SPICA where low-noise and high sensitivity is required to achieve ambitious science goals. In this paper we describe a modal analysis of multi-moded horn antennas feeding integrating cavities housing TES detectors with superconducting film absorbers. In high sensitivity TES detector technology the ability to control the electromagnetic and thermo-mechanical environment of the detector is critical. Simulating and understanding optical behaviour of such detectors at far IR wavelengths is difficult and requires development of existing analysis tools. The proposed modal approach offers a computationally efficient technique to describe the partial coherent response of the full pixel in terms of optical efficiency and power leakage between pixels. Initial wok carried out as part of an ESA technical research project on optical analysis is described and a prototype SAFARI pixel design is analyzed where the optical coupling between the incoming field and the pixel containing horn, cavity with an air gap, and thin absorber layer are all included in the model to allow a comprehensive optical characterization. The modal approach described is based on the mode matching technique where the horn and cavity are described in the traditional way while a technique to include the absorber was developed. Radiation leakage between pixels is also included making this a powerful analysis tool.

  16. Online calculation of the Tevatron collider luminosity using accelerator instrumentation

    International Nuclear Information System (INIS)

    Hahn, A.A.

    1997-07-01

    The luminosity of a collision region may be calculated if one understands the lattice parameters and measures the beam intensities, the transverse and longitudinal emittances, and the individual proton and antiproton beam trajectories (space and time) through the collision region. This paper explores an attempt to make this calculation using beam instrumentation during Run 1b of the Tevatron. The instrumentation used is briefly described. The calculations and their uncertainties are compared to luminosities calculated independently by the Collider Experiments (CDF and D0)

  17. Incorporating Basic Optical Microscopy in the Instrumental Analysis Laboratory

    Science.gov (United States)

    Flowers, Paul A.

    2011-01-01

    A simple and versatile approach to incorporating basic optical microscopy in the undergraduate instrumental analysis laboratory is described. Attaching a miniature CCD spectrometer to the video port of a standard compound microscope yields a visible microspectrophotometer suitable for student investigations of fundamental spectrometry concepts,…

  18. Matter in Extreme Conditions Instrument - Conceptual Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Boyce, R.F.; Boyce, R.M.; Haller, G.; Hastings, J.B.; Hays, G.; Lee, H.J.; /SLAC; Lee, R.W.; /LLNL, Livermore; Nagler, B.; /Rutherford; Scharfenstein, M.; Marsh, D.; White, W.E.; /SLAC

    2009-12-09

    The SLAC National Accelerator Laboratory (SLAC), in collaboration with Argonne National Laboratory (ANL), Lawrence Livermore National Laboratory (LLNL), and the University of California at Los Angeles (UCLA), is constructing a Free-Electron Laser (FEL) research facility. The FEL has already met its performance goals in the wavelength range 1.5 nm - 0.15 nm. This facility, the Linac Coherent Light Source (LCLS), utilizes the SLAC 2-Mile Linear Accelerator (linac) and will produce sub-picosecond pulses of short wavelength X-rays with very high peak brightness and almost complete transverse coherence. The final one-third of the SLAC linac is used as the source of electrons for the LCLS. The high energy electrons are transported across the SLAC Research Yard, into a tunnel which houses a long undulator. In passing through the undulator, the electrons are bunched by the force of their own synchrotron radiation and produce an intense, monochromatic, spatially coherent beam of X-rays. By varying the electron energy, the FEL X-ray wavelength is tunable from 1.5 nm to 0.15 nm. The LCLS includes two experimental halls as well as X-ray optics and infrastructure necessary to create a facility that can be developed for research in a variety of disciplines such as atomic physics, materials science, plasma physics and biosciences. This Conceptual Design Report, the authors believe, confirms the feasibility of designing and constructing an X-ray instrument in order to exploit the unique scientific capability of LCLS by creating extreme conditions and study the behavior of plasma under those controlled conditions. This instrument will address the Office of Science, Fusion Energy Sciences, mission objective related to study of Plasma and Warm Dense Matter as described in the report titled LCLS, the First Experiments, prepared by the LCLS Scientific Advisory Committee (SAC) in September 2000. The technical objective of the LCLS Matter in Extreme Conditions (MEC) Instrument project is

  19. Computer-based instrumentation for partial discharge detection in GIS

    International Nuclear Information System (INIS)

    Md Enamul Haque; Ahmad Darus; Yaacob, M.M.; Halil Hussain; Feroz Ahmed

    2000-01-01

    Partial discharge is one of the prominent indicators of defects and insulation degradation in a Gas Insulated Switchgear (GIS). Partial discharges (PD) have a harmful effect on the life of insulation of high voltage equipment. The PD detection using acoustic technique and subsequent analysis is currently an efficient method of performing non-destructive testing of GIS apparatus. A low cost PC-based acoustic PD detection instrument has been developed for the non-destructive diagnosis of GIS. This paper describes the development of a PC-based instrumentation system for partial discharge detection in GIS and some experimental results have also presented. (Author)

  20. Imaging instrument for positron emitting heavy ion beam injection

    International Nuclear Information System (INIS)

    Llacer, J.; Chatterjee, A.; Jackson, H.C.; Lin, J.C.; Zunzunegui, M.V.

    1978-10-01

    The design and performance of an instrument for the imaging of coincidence annihilation gamma rays emitted from the end point of the trajectories of radioactive high-energy heavy ions is described. The positron-emitting heavy ions are the result of nuclear fragmentation of accelerated heavy ions used in cancer therapy or diagnostic medicine. The instrument constructed is capable of locating the ion beam trajectory end point within 1 mm for an injected activity of 200 nanoCi in a measurement time of 1 sec in some favorable conditions. Limited imaging in three dimensions is also demonstrated

  1. Microprocessor-controlled data-acquisition instrument for neutron-activation measurements

    International Nuclear Information System (INIS)

    Jones, B.A.

    1981-01-01

    This paper describes a microprocessor controlled data acquisition instrument designed at Lawrence Livermore National Laboratory to provide experimenters with a diagnostic tool for measuring the performance of laser imploded fusion targets via neutron activation techniques. This instrument features the ability to count four independent inputs simultaneously while providing a front panel readout of these inputs, plus a time of day clock. A hardcopy printout of the data is also provided by a built-in thermal printer. All running modes and parameters are user selectable via a front panel keypad, and a complete set of internal self-testing diagnostics are available for debug

  2. Status Report on Efforts to Enhance Instrumentation to Support Advanced Test Reactor Irradiations

    Energy Technology Data Exchange (ETDEWEB)

    J. Rempe; D. Knudson; J. Daw; T. Unruh; B. Chase; R. Schley; J. Palmer; K. Condie

    2014-01-01

    The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support the growth of nuclear science and technology in the United States (US). By attracting new research users - universities, laboratories, and industry - the ATR NSUF facilitates basic and applied nuclear research and development, further advancing the nation's energy security needs. A key component of the ATR NSUF effort at the Idaho National Laboratory (INL) is to design, develop, and deploy new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. To address this need, an assessment of instrumentation available and under-development at other test reactors was completed. Based on this initial review, recommendations were made with respect to what instrumentation is needed at the ATR, and a strategy was developed for obtaining these sensors. In 2009, a report was issued documenting this program’s strategy and initial progress toward accomplishing program objectives. Since 2009, annual reports have been issued to provide updates on the program strategy and the progress made on implementing the strategy. This report provides an update reflecting progress as of January 2014.

  3. Nuclear and fundamental physics instrumentation for the ANS project

    International Nuclear Information System (INIS)

    Robinson, S.J.; Faust, H.; Piotrowski, A.E.

    1996-05-01

    This report summarizes work carried out during the period 1991-1995 in connection with the refinement of the concepts and detailed designs for nuclear and fundamental physics research instrumentation at the proposed Advanced Neutron source at Oak Ridge National Laboratory. Initially, emphasis was placed on refining the existing System Design Document (SDD-43) to detail more accurately the needs and interfaces of the instruments that are identified in the document. The conceptual designs of these instruments were also refined to reflect current thinking in the field of nuclear and fundamental physics. In particular, the on-line isotope separator (ISOL) facility design was reconsidered in the light of the development of interest in radioactive ion beams within the nuclear physics community. The second stage of this work was to define those instrument parameters that would interface directly with the reactor systems so that these parameters could be considered for the ISOL facility and particularly for its associated ion source. Since two of these options involved ion sources internal to the long slant beam tube, these were studied in detail. In addition, preliminary work was done to identify the needs for the target holder and changing facility to be located in the tangential through-tube. Because many of the planned nuclear and fundamental physics instruments have similar needs in terms of detection apparatus, some progress was also made in defining the parameters for these detectors. 21 refs., 32 figs., 2 tabs

  4. Post-implementation review of inadequate core cooling instrumentation

    International Nuclear Information System (INIS)

    Anderson, J.L.; Anderson, R.L.; Hagen, E.W.; Morelock, T.C.; Huang, T.L.; Phillips, L.E.

    1988-01-01

    Studies of Three Mile Island (TMI) accident identified the need for additional instrumentation to detect inadequate core cooling (ICC) in nuclear power plants. Industry studies by plant owners and reactor vendors supported the conclusion that improvements were needed to help operators diagnose the approach to or existence of ICC and to provide more complete information for operator control of safety injection, flow to minimize the consequences of such an accident. In 1980, the US Nuclear Regulatory Commission (NRC) required further studies by the industry and described ICC instrumentation design requirements that included human factors and environmental considerations. On December 10, 1982, NRC issued to Babcock and Wilcox (BandW) licensees' orders for Modification of License and transmitted to all pressurized water reactor (PWR) licensees Generic Letter 82-28 to inform them of the revised NRC requirements. The instrumentation requirements for detection of ICC include upgraded subcooling margin monitors (SMMs), upgraded core exit thermocouples (CETs), and installation of a reactor coolant inventory tracking system (RCITS)

  5. Evolution of the VLT instrument control system toward industry standards

    Science.gov (United States)

    Kiekebusch, Mario J.; Chiozzi, Gianluca; Knudstrup, Jens; Popovic, Dan; Zins, Gerard

    2010-07-01

    The VLT control system is a large distributed system consisting of Linux Workstations providing the high level coordination and interfaces to the users, and VME-based Local Control Units (LCU's) running the VxWorks real-time operating system with commercial and proprietary boards acting as the interface to the instrument functions. After more than 10 years of VLT operations, some of the applied technologies used by the astronomical instruments are being discontinued making it difficult to find adequate hardware for future projects. In order to deal with this obsolescence, the VLT Instrumentation Framework is being extended to adopt well established Commercial Off The Shelf (COTS) components connected through industry standard fieldbuses. This ensures a flexible state of the art hardware configuration for the next generation VLT instruments allowing the access to instrument devices via more compact and simpler control units like PC-based Programmable Logical Controllers (PLC's). It also makes it possible to control devices directly from the Instrument Workstation through a normal Ethernet connection. This paper outlines the requirements that motivated this work, as well as the architecture and the design of the framework extension. In addition, it describes the preliminary results on a use case which is a VLTI visitor instrument used as a pilot project to validate the concepts and the suitability of some COTS products like a PC-based PLCs, EtherCAT8 and OPC UA6 as solutions for instrument control.

  6. Assessing hospitals' clinical risk management: Development of a monitoring instrument

    Directory of Open Access Journals (Sweden)

    Pfeiffer Yvonne

    2010-12-01

    Full Text Available Abstract Background Clinical risk management (CRM plays a crucial role in enabling hospitals to identify, contain, and manage risks related to patient safety. So far, no instruments are available to measure and monitor the level of implementation of CRM. Therefore, our objective was to develop an instrument for assessing CRM in hospitals. Methods The instrument was developed based on a literature review, which identified key elements of CRM. These elements were then discussed with a panel of patient safety experts. A theoretical model was used to describe the level to which CRM elements have been implemented within the organization. Interviews with CRM practitioners and a pilot evaluation were conducted to revise the instrument. The first nationwide application of the instrument (138 participating Swiss hospitals was complemented by in-depth interviews with 25 CRM practitioners in selected hospitals, for validation purposes. Results The monitoring instrument consists of 28 main questions organized in three sections: 1 Implementation and organizational integration of CRM, 2 Strategic objectives and operational implementation of CRM at hospital level, and 3 Overview of CRM in different services. The instrument is available in four languages (English, German, French, and Italian. It allows hospitals to gather comprehensive and systematic data on their CRM practice and to identify areas for further improvement. Conclusions We have developed an instrument for assessing development stages of CRM in hospitals that should be feasible for a continuous monitoring of developments in this important area of patient safety.

  7. Assessing hospitals' clinical risk management: Development of a monitoring instrument.

    Science.gov (United States)

    Briner, Matthias; Kessler, Oliver; Pfeiffer, Yvonne; Wehner, Theo; Manser, Tanja

    2010-12-13

    Clinical risk management (CRM) plays a crucial role in enabling hospitals to identify, contain, and manage risks related to patient safety. So far, no instruments are available to measure and monitor the level of implementation of CRM. Therefore, our objective was to develop an instrument for assessing CRM in hospitals. The instrument was developed based on a literature review, which identified key elements of CRM. These elements were then discussed with a panel of patient safety experts. A theoretical model was used to describe the level to which CRM elements have been implemented within the organization. Interviews with CRM practitioners and a pilot evaluation were conducted to revise the instrument. The first nationwide application of the instrument (138 participating Swiss hospitals) was complemented by in-depth interviews with 25 CRM practitioners in selected hospitals, for validation purposes. The monitoring instrument consists of 28 main questions organized in three sections: 1) Implementation and organizational integration of CRM, 2) Strategic objectives and operational implementation of CRM at hospital level, and 3) Overview of CRM in different services. The instrument is available in four languages (English, German, French, and Italian). It allows hospitals to gather comprehensive and systematic data on their CRM practice and to identify areas for further improvement. We have developed an instrument for assessing development stages of CRM in hospitals that should be feasible for a continuous monitoring of developments in this important area of patient safety.

  8. The Progress in Localization Initiatives in PDC, BST

    International Nuclear Information System (INIS)

    Rosli Darmawan; Hasni Hassan; Anwar Abdul Rahman

    2011-01-01

    Nuclear Malaysia has been established since 1972. It has evolves from laying the foundation for infrastructure and human resources in nuclear technology; research and development in nuclear applications; producing new products and prototypes; and finally, transferring the products and technology to the end users such as the industry and communities. While Nuclear Malaysia has been able to develop various nuclear applications, there are areas which have been left behind. Most of the facilities and instruments for nuclear Research and Development are imported. Although Nuclear Malaysia has been able to operate and maintain the facilities, there are occasions where the foreign experts and components need to be sought for. This dependency on foreign technology has cost Nuclear Malaysia a lot, especially in the maintenance and procurement of new instruments and spare parts. To reduce this dependency, some localization initiatives have been conducted by various groups in Nuclear Malaysia. This paper discusses the recent progress and achievement of localization initiatives undertaken by PDC on the related technology which has reduced the dependency on foreign experts and technology. (author)

  9. Development of an inter-professional screening instrument for cancer patients' education process.

    Science.gov (United States)

    Vaartio-Rajalin, Heli; Huumonen, Tuula; Iire, Liisa; Jekunen, Antti; Leino-Kilpi, Helena; Minn, Heikki; Paloniemi, Jenni; Zabalegui, Adelaida

    2016-02-01

    The aim of this paper is to describe the development of an inter-professional screening instrument for cancer patients' cognitive resources, knowledge expectations and inter-professional collaboration within patient education. Four empirical datasets during 2012-2014 were analyzed in order to identify main categories, subcategories and items for inter-professional screening instrument. Our inter-professional screening instrument integrates the critical moments of cancer patient education and the knowledge expectation types obtained from patient datasets to assessment of patients' cognitive resources, knowledge expectations and comprehension; and intra; and inter-professional. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. netherland hydrological modeling instrument

    Science.gov (United States)

    Hoogewoud, J. C.; de Lange, W. J.; Veldhuizen, A.; Prinsen, G.

    2012-04-01

    decision supports and evaluations. The main focus of the instrument is operational drought management and evaluating adaptive measures for different climate scenario's. It has also been used though as a basis to evaluate water quality of WFD-water bodies and measures, nutrient-leaching and describing WFD groundwater bodies. There is a toolkit to translate the hydrological NHI results to values for different water users. For instance with the NHI results agricultural yields can be calculated, effects on ground water dependant ecosystems, subsidence, shipping, drinking water supply. This makes NHI a valuable decision support system in Dutch water management.

  11. Development of a portable ambient temperature radiometric assaying instrument

    International Nuclear Information System (INIS)

    Lavietes, A.D.; McQuaid, J.H.; Ruhter, W.D.; Paulus, T.J.

    1995-01-01

    There is a strong need for portable radiometric instrumentation that can accurately confirm the presence of nuclear materials and allow isotopic analysis of radionuclides in the field. To fulfill this need, the authors are developing a hand-held, non-cryogenic, low-power gamma- and X-ray measurement and analysis instrument that can both search and then accurately verify the presence of nuclear materials. The authors report on the use of cadmium zinc telluride detectors, signal processing electronics, and the new field-portable instrument based on the MicroNOMAD Multichannel Analyzer from EG and G ORTEC. They will also describe the isotopic analysis that allows uranium enrichment measurements to be made accurately in the field. The benefits of this work are realized in a wide spectrum of applications that include Arms Control, Nuclear Safeguards, Environmental Management, Emergency Response, and Treaty Verification

  12. Upgrade of the NCSU PULSTAR instrumentation power channels. Final technical report, September 1, 1992 - August 31, 1994

    International Nuclear Information System (INIS)

    Perez, P.B.

    1998-01-01

    The Nuclear Reactor Program at North Carolina State University initiated an upgrade program at the NCSU PULSTAR Reactor in 1990. The originally supplied instrumentation has been replaced with solid-state and current technology equipment. The financial assistance from the US Department of Energy has been the primary source of support. This is the final report for the Instrumentation Upgrade

  13. University of Houston Undergraduate Student Instrumentation Projects

    Science.gov (United States)

    Bering, E. A., III; Talbot, R. W.; Hampton, D. L.; Molders, N.; Millan, R. M.; Halford, A. J.; Dunbar, B.; Morris, G. A.; Prince, J.; Gamblin, R.; Ehteshami, A.; Lehnen, J. N.; Greer, M.; Porat, I.; Alozie, M.; Behrend, C. C.; Bias, C.; Fenton, A.; Gunawan, B.; Harrison, W.; Martinez, A.; Mathur, S.; Medillin, M.; Nguyen, T.; Nguyen, T. V.; Nowling, M.; Perez, D.; Pham, M.; Pina, M.; Thomas, G.; Velasquez, B.; Victor, L.

    2017-12-01

    The Undergraduate Student Instrumentation Project (USIP) is a NASA program to engage undergraduate students in rigorous scientific research, for the purposes of innovation and developing the next generation of professionals for an array of fields. The program is student led and executed from initial ideation to research to the design and deployment of scientific payloads. The University of Houston has been selected twice to participate in the USIP programs. The first program (USIP_UH I) ran from 2013 to 2016. USIP_UH II started in January of 2016, with funding starting at the end of May. USIP_UH I (USIP_UH II) at the University of Houston was (is) composed of eight (seven) research teams developing six (seven), distinct, balloon-based scientific instruments. These instruments will contribute to a broad range of geophysical sciences from Very Low Frequency recording and Total Electron Content to exobiology and ozone profiling. USIP_UH I had 12 successful launches with 9 recoveries from Fairbanks, AK in March 2015, and 4 piggyback flights with BARREL 3 from Esrange, Kiruna, Sweden in August, 2015. USIP_UH II had 8 successful launches with 5 recoveries from Fairbanks, AK in March 2017, 3 piggyback flights with BARREL 4 from Esrange, Kiruna, Sweden in August, 2016, and 1 flight each from CSBF and UH. The great opportunity of this program is capitalizing on the proliferation of electronics miniaturization to create new generations of scientific instruments that are smaller and lighter than ever before. This situation allows experiments to be done more cheaply which ultimately allows many more experiments to be done.

  14. Intercomparison of two comparative reactivity method instruments inf the Mediterranean basin during summer 2013

    Science.gov (United States)

    Zannoni, N.; Dusanter, S.; Gros, V.; Sarda Esteve, R.; Michoud, V.; Sinha, V.; Locoge, N.; Bonsang, B.

    2015-09-01

    The hydroxyl radical (OH) plays a key role in the atmosphere, as it initiates most of the oxidation processes of volatile organic compounds (VOCs), and can ultimately lead to the formation of ozone and secondary organic aerosols (SOAs). There are still uncertainties associated with the OH budget assessed using current models of atmospheric chemistry and direct measurements of OH sources and sinks have proved to be valuable tools to improve our understanding of the OH chemistry. The total first order loss rate of OH, or total OH reactivity, can be directly measured using three different methods, such as the following: total OH loss rate measurement, laser-induced pump and probe technique and comparative reactivity method. Observations of total OH reactivity are usually coupled to individual measurements of reactive compounds in the gas phase, which are used to calculate the OH reactivity. Studies using the three methods have highlighted that a significant fraction of OH reactivity is often not explained by individually measured reactive compounds and could be associated to unmeasured or unknown chemical species. Therefore accurate and reproducible measurements of OH reactivity are required. The comparative reactivity method (CRM) has demonstrated to be an advantageous technique with an extensive range of applications, and for this reason it has been adopted by several research groups since its development. However, this method also requires careful corrections to derive ambient OH reactivity. Herein we present an intercomparison exercise of two CRM instruments, CRM-LSCE (Laboratoire des Sciences du Climat et de l'Environnement) and CRM-MD (Mines Douai), conducted during July 2013 at the Mediterranean site of Ersa, Cape Corsica, France. The intercomparison exercise included tests to assess the corrections needed by the two instruments to process the raw data sets as well as OH reactivity observations. The observation was divided in three parts: 2 days of plant

  15. Strategy for the development of EU Test Blanket Systems instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Calderoni, P., E-mail: Pattrick.Calderoni@f4e.europa.eu; Ricapito, I.; Poitevin, Y.

    2013-10-15

    Highlights: • We developed a strategy for the development of instrumentation for EU ITER TBSs. • TBSs instrumentation functions: safety, operation and scientific mission. • Described activities are in support of ITER design review process. -- Abstract: The instrumentation of the HCLL and HCPB Test Blanket System is fundamental in ensuring that ITER safety and operational requirements are satisfied as well as in enabling the scientific mission of the TBM program. It carries out three essential functions: (i) safety, intended as compliance with ITER requirements toward public and workers protection; (ii) system control, intended as compliance with ITER operational requirements and investment protection; and (iii) scientific mission, intended as validating technology and predictive tools for blanket concepts relevant to fusion energy systems. This paper describes the strategy for instrumentation development by providing details of the following five steps to be implemented in procured activities in the short to mid-term (3–4 years): (i) provide mapping of sensors requirements based on critical review of preliminary design data; (ii) develop functional specifications for TBS sensors based on the analysis of operative conditions in the various ITER buildings in which they are located; (iii) assess availability of commercial sensors against developed specifications; (iv) develop prototypes when no available solution is identified; and (v) perform single effect tests for the most critical solicitations and post-test examination of commercial products and prototypes. Examples of technology assessment in two technical areas are included to reinforce and complement the strategy description.

  16. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2000-01-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised

  17. Fault-tolerant NAND-flash memory module for next-generation scientific instruments

    Science.gov (United States)

    Lange, Tobias; Michel, Holger; Fiethe, Björn; Michalik, Harald; Walter, Dietmar

    2015-10-01

    Remote sensing instruments on today's space missions deliver a high amount of data which is typically evaluated on ground. Especially for deep space missions the telemetry downlink is very limited which creates the need for the scientific evaluation and thereby a reduction of data volume already on-board the spacecraft. A demanding example is the Polarimetric and Helioseismic Imager (PHI) instrument on Solar Orbiter. To enable on-board offline processing for data reduction, the instrument has to be equipped with a high capacity memory module. The module is based on non-volatile NAND-Flash technology, which requires more advanced operation than volatile DRAM. Unlike classical mass memories, the module is integrated into the instrument and allows readback of data for processing. The architecture and safe operation of such kind of memory module is described in the following paper.

  18. Scaling and instrumentation of the LOFT facility

    International Nuclear Information System (INIS)

    Modro, S.M.; Goodrich, L.D.; McPherson, G.D.

    1985-01-01

    This paper describes the LOFT experimental facility and instrumentation of the facility during small break loss-of-coolant experiments. Basic scaling considerations applied in the facility design are presented. Because LOFT was not designed with emphasis on small break LOCA some atypicalities with regard to small break transients are discussed. Review of important small break LOCA phenomena observed during the experiments and their measurability is provided

  19. [Prediction instrument for obesity in adolescents at the Policlínico Universitario "Manuel González Díaz", 2013-2014].

    Science.gov (United States)

    Piña Borrego, Carlos Enrique; Fernández Fernández, María de Lourdes; Fonte Rodríguez, Norge; Piña Rodríguez, Lorena Karla

    Obesity is one of the principal non declarable diseases affecting children and adolescents. With the objective of developing a predictive instrument to identify high-risk adolescents with obesity, a cohort prospective study was carried out at the Policlinic "Manuel González Díaz", Bahía Honda City from 2013-2014. It was developed in three stages. In the first stage, 1800 adolescents from 10-19 years of age were included. The prevalence was identified and the most relevant characteristics of obesity were described (defined as body mass index >97 th percentile according to age and sex). In the second stage we identified the possibility of the diagnosis of factors that increase the probability of obesity. The third stage elaborated and validated an obesity predictor instrument from the results of the initial stages. To apply the instrument to sample A for internal elaboration and validation, sensitivity was 77.78% and specificity was 86.11%. Area under the curve (AUC) receiver operating characteristic (ROC) was 0.86, whereas for sample B the sensitivity was 79.63% and specificity was 92.13%. Positive predictive value (PPV) was 83.5% and negative predictive value (NPV) was 90.05%. The instrument allows predicting the risk for developing obesity in adolescents with acceptable sensitivity and high specificity. Its routine application will be interesting in pediatric health consultations. Copyright © 2014 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  20. An Undergraduate Student Instrumentation Project (USIP) to Develop New Instrument Technology to Study the Auroral Ionosphere and Stratospheric Ozone Layer Using Ultralight Balloon Payloads

    Science.gov (United States)

    Nowling, M.; Ahmad, H.; Gamblin, R.; Guala, D.; Hermosillo, D.; Pina, M.; Marrero, E.; Canales, D. R. J.; Cao, J.; Ehteshami, A.; Bering, E. A., III; Lefer, B. L.; Dunbar, B.; Bias, C.; Shahid, S.

    2015-12-01

    This project is currently engaging twelve undergraduate students in the process of developing new technology and instrumentation for use in balloon borne geospace investigations in the auroral zone. Motivation stems from advances in microelectronics and consumer electronic technology. Given the technological innovations over the past 20 years it now possible to develop new instrumentation to study the auroral ionosphere and stratospheric ozone layer using ultralight balloon payloads for less than 6lbs and $3K per payload. The University of Houston Undergraduate Student Instrumentation Project (USIP) team has built ten such payloads for launch using 1500 gm latex weather balloons deployed in Houston, TX, Fairbanks, AK, and as well as zero pressure balloons launched from northern Sweden. The latex balloon project will collect vertical profiles of wind velocity, temperature, electrical conductivity, ozone, and odd nitrogen. This instrument payload will also produce profiles of pressure, electric field, and air-earth electric current. The zero pressure balloons will obtain a suite of geophysical measurements including: DC electric field, electric field and magnetic flux, optical imaging, total electron content of ionosphere via dual-channel GPS, X-ray detection, and infrared/UV spectroscopy. Students flew payloads with different combinations of these instruments to determine which packages are successful. Data collected by these instruments will be useful in understanding the nature of electrodynamic coupling in the upper atmosphere and how the global earth system is changing. Twelve out of the launched fifteen payloads were successfully launched and recovered. Results and best practices learned from lab tests and initial Houston test flights will be discussed.

  1. Measurement properties of quality of life measurement instruments for infants, children and adolescents with eczema: protocol for a systematic review.

    Science.gov (United States)

    Heinl, Daniel; Prinsen, Cecilia A C; Drucker, Aaron M; Ofenloch, Robert; Humphreys, Rosemary; Sach, Tracey; Flohr, Carsten; Apfelbacher, Christian

    2016-02-09

    Eczema is a common chronic or chronically relapsing, inflammatory skin disease that exerts a substantial negative impact on quality of life (QoL). The Harmonising Outcome Measures for Eczema (HOME) initiative has used a consensus-based process which identified QoL as one of the four core outcome domains to be assessed in all eczema clinical trials. A number of measurement instruments exist to measure QoL in infants, children, and adolescents with eczema, and there is a great variability in both content and quality of the instruments used. Therefore, the objective of the proposed research is to comprehensively and systematically assess the measurement properties of the existing measurement instruments that were developed and/or validated for the measurement of patient-reported QoL in infants, children, and adolescents with eczema. This study is a systematic review of the measurement properties of patient-reported measures of QoL developed and/or validated for infants, children, and adolescents with eczema. A systematic literature search will be carried out in MEDLINE via PubMed and EMBASE using a selection of relevant search terms. Eligible studies will be primary empirical studies evaluating, describing, or comparing measurement properties of QoL instruments for infants, children, and adolescents with eczema. Two reviewers will independently perform eligibility assessment and data abstraction. Evidence tables will be used to record study characteristics, instrument characteristics, measurement properties, and interpretability. The adequacy of the measurement properties will be assessed using predefined criteria. The COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist will be used to evaluate the methodological quality of included studies. A best evidence synthesis will be undertaken if more than one study has examined a particular measurement property. The proposed systematic review will yield a comprehensive assessment

  2. Monitoring Instrument Performance in Regional Broadband Seismic Network Using Ambient Seismic Noise

    Science.gov (United States)

    Ye, F.; Lyu, S.; Lin, J.

    2017-12-01

    In the past ten years, the number of seismic stations has increased significantly, and regional seismic networks with advanced technology have been gradually developed all over the world. The resulting broadband data help to improve the seismological research. It is important to monitor the performance of broadband instruments in a new network in a long period of time to ensure the accuracy of seismic records. Here, we propose a method that uses ambient noise data in the period range 5-25 s to monitor instrument performance and check data quality in situ. The method is based on an analysis of amplitude and phase index parameters calculated from pairwise cross-correlations of three stations, which provides multiple references for reliable error estimates. Index parameters calculated daily during a two-year observation period are evaluated to identify stations with instrument response errors in near real time. During data processing, initial instrument responses are used in place of available instrument responses to simulate instrument response errors, which are then used to verify our results. We also examine feasibility of the tailing noise using data from stations selected from USArray in different locations and analyze the possible instrumental errors resulting in time-shifts used to verify the method. Additionally, we show an application that effects of instrument response errors that experience pole-zeros variations on monitoring temporal variations in crustal properties appear statistically significant velocity perturbation larger than the standard deviation. The results indicate that monitoring seismic instrument performance helps eliminate data pollution before analysis begins.

  3. Performing the Super Instrument

    DEFF Research Database (Denmark)

    Kallionpaa, Maria

    2016-01-01

    can empower performers by producing super instrument works that allow the concert instrument to become an ensemble controlled by a single player. The existing instrumental skills of the performer can be multiplied and the qualities of regular acoustic instruments extended or modified. Such a situation......The genre of contemporary classical music has seen significant innovation and research related to new super, hyper, and hybrid instruments, which opens up a vast palette of expressive potential. An increasing number of composers, performers, instrument designers, engineers, and computer programmers...... have become interested in different ways of “supersizing” acoustic instruments in order to open up previously-unheard instrumental sounds. Super instruments vary a great deal but each has a transformative effect on the identity and performance practice of the performing musician. Furthermore, composers...

  4. A new LIF instrument for aircraft related and ground related masurements of OH and HO{sub 2} radicals in the troposphere; Ein neues LIF-Instrument fuer flugzeug- und bodengebundene Messungen von OH- und HO{sub 2}-Radikalen in der Troposphaere

    Energy Technology Data Exchange (ETDEWEB)

    Broch, Sebastian

    2011-07-01

    The author of the contribution under consideration describes the development and characterization of an instrument for the measurement of OH and HO{sub 2} radicals by means of laser-induced fluorescence (LIF). This instrument can be used from the lower troposphere to the lower stratosphere both on the ground and in aircraft applications. After describing the basics of the OH radical chemistry and the measurement principle of laser-induced fluorescence, a new instrument is presented. The LIF measuring cells needs long inlet pipes which lead to a modification of the verification of OH radicals. The effect of these modifications as well as the height dependence of the detection sensitivity for the OH radicals is examined. A model for the theoretical description of the altitude dependence of the detection sensitivity is described. The modification of the measuring cell influences the ozone-water interference in the LIF measurement system. Therefore, the author develops a model to describe the interference in the new system and evaluate this model by measurements. The applicability of this new instrument for ground and flight applications is analyzed in the range from 0 to 18 kilometers regarding sensitivity, detection limit and interference.

  5. Analysis and application of analog electronic circuits to biomedical instrumentation

    CERN Document Server

    Northrop, Robert B

    2003-01-01

    This book introduces the basic mathematical tools used to describe noise and its propagation through linear systems and provides a basic description of the improvement of signal-to-noise ratio by signal averaging and linear filtering. The text also demonstrates how op amps are the keystone of modern analog signal conditioning systems design, and illustrates their use in isolation and instrumentation amplifiers, active filters, and numerous biomedical instrumentation systems and subsystems. It examines the properties of the ideal op amp and applies this model to the analysis of various circuits

  6. Wide-range bipolar pulse conductance instrument employing current and voltage modes with sampled or integrated signal acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Calhoun, R K; Holler, F J [Kentucky Univ., Lexington, KY (United States). Dept. of Chemistry; Geiger, jr, R F; Nieman, T A [Illinois Univ., Urbana, IL (United States). Dept. of Chemistry; Caserta, K J [Procter and Gamble Co., Cincinnati, OH (United States)

    1991-11-05

    An instrument for measuring solution conductance using the bipolar pulse technique is described. The instrument is capable of measuring conductances in the range of 5x10{sup -9}-10{Omega}{sup -1} with 1% accuracy or better in as little as 32 {mu}s. Accuracy of 0.001-0.01% is achievable over the range 1x10{sup -6}-1{Omega}{sup -1}. Circuitry and software are described that allow the instrument to adjust automatically the pulse height, pulse duration, excitation mode (current or voltage pulse) and data acquisition mode (sampled or integrated) to acquire data of optimum accuracy and precision. The urease-catalyzed decomposition of urea is used to illustrate the versality of the instrument, and other applications are cited. (author). 60 refs.; 7 figs.; 2 tabs.

  7. Instrumentation and process control development for in situ coal gasification. Fourth quarterly report, September--November 1975

    Energy Technology Data Exchange (ETDEWEB)

    Northrop, D.A. (ed.)

    1976-01-01

    The instrumentation effort for Phases 2 and 3 of the Second Hanna In Situ Coal Gasification Experiment was fielded and background data obtained prior to the initiation of Phase 2 on November 25, 1975. A total of over 600 channels of instrumentation in 15 instrumentation wells and two surface arrays was fielded for the instrumentation techniques under evaluation. The feasibility of the passive acoustic technique to locate the source of process-related noises has been demonstrated; its utility is presently hampered by the inexact definition of signal arrivals and the lack of automated signal monitoring and analysis systems. A revised mathematical model for the electrical techniques has been developed which demonstrates the potential for remote monitoring. (auth)

  8. Instrumentation and controls training in TVA: a story of large numbers

    International Nuclear Information System (INIS)

    Conner, D.L.

    1981-01-01

    The Tennessee Valley Authority currently has four nuclear units on line with seventeen units planned prior to the year 2000. Providing a permanent instrumentation and controls workforce, projected to be approximately 700 trades and labor craftsmen, is a formidable task requiring the cooperative efforts of many diverse groups: mangement and labor, engineers and craftsmen, students and instructors. In TVA, the primary source of skilled I and C craftsmen is through formal training programs conducted in cooperation with the craft bargaining unit, the International Brotherhood of Electrical Workers. The purpose of this paper is to describe and review the progress of two of these programs: the Instrument Mechanic Training Program and the Senior Instrument Mechanic Training Program

  9. The Ukrainian Bandura as a Musical Instrument of the Chordophone Group

    Directory of Open Access Journals (Sweden)

    Violetta Dutchak

    2017-10-01

    Full Text Available The article examines the characteristics of the bandura as a plucked chordophone. A comparative analysis of the researches undertaken by outstanding musicologists, performers, ethno-organologists S. Lyudkevych, E. Hornbostel, C. Sachs, H. Khotkevych, Z. Shtokalko, and others is carried out. The morphology of the instrument and the main stages in its evolution are discussed. The stable and mobile elements of the bandura’s structure and tuning are described. The technical characteristics of the instrument in different periods of its evolution and the achievements of the bandura makers and bandurists of Ukraine and the Ukrainian diaspora are analyzed. The common and distinguishing features of the bandura and some kindred instruments are pointed out.

  10. Seismic qualification of safety-related instrumentation cabinets for nuclear generating stations

    International Nuclear Information System (INIS)

    Sauve, R.G.; Bell, R.P.; Cuttler, J.M.

    1979-06-01

    The problem of seismically qualifying different electrical instruments mounted in cabinets of a standard design is discussed and the following economical approach is described in detail. An analytical model of the cabinet structure is developed and validated by comparison with the results of shake table tests on a prototype cabinet. Modal analysis is then used to calculate the input spectra for shake table tests to qualify the individual instruments that are mounted at the required elevations in the cabinet. The worst input spectrum, appropriate to qualify each instrument, is then specified to the suppliers. This approach avoids the need to test each cabinet configuration in an assembled state in order to qualify it. (auth)

  11. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2000-07-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised.

  12. Instrument evaluation no.14: Wallac laboratory contamination meter RD 11

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1979-01-01

    An instrument for measuring low level contamination and consisting of a detachable Geiger-Muller tube probe, connected to a rate meter by a coiled extensible tube is described. Facilities and controls, performance, electrical, environmental and mechanical characteristics are included. (UK)

  13. Method to deterministically study photonic nanostructures in different experimental instruments

    NARCIS (Netherlands)

    Husken, B.H.; Woldering, L.A.; Blum, Christian; Tjerkstra, R.W.; Vos, Willem L.

    2009-01-01

    We describe an experimental method to recover a single, deterministically fabricated nanostructure in various experimental instruments without the use of artificially fabricated markers, with the aim to study photonic structures. Therefore, a detailed map of the spatial surroundings of the

  14. The Standard, Power, and Color Model of Instrument Combination in Romantic-Era Symphonic Works

    Directory of Open Access Journals (Sweden)

    Randolph Johnson

    2011-08-01

    Full Text Available The Standard, Power, and Color (SPC model describes the nexus between musical instrument combination patterns and expressive goals in music. Instruments within each SPC group tend to attract each other and work as a functional unit to create orchestral gestures. Standard instruments establish a timbral groundwork; Power instruments create contrast through loud dynamic climaxes; and Color instruments catch listeners’ attention by means of their sparing use. Examples within these three groups include violin (Standard, piccolo (Power, and harp (Color. The SPC theory emerges from analyses of nineteenth-century symphonic works. Multidimensional scaling analysis of instrument combination frequencies maps instrument relationships; hierarchical clustering analysis indicates three SPC groups within the map. The SPC characterization is found to be moderately robust through the results of hypothesis testing: (1 Color instruments are included less often in symphonic works; (2 when Color instruments are included, they perform less often than the average instrument; and (3 Color and non-Color instruments have equal numbers of solo occurrences. Additionally, (4 Power instruments are positively associated with louder dynamic levels; and (5 when Power instruments are present in the musical texture, the pitch range spanned by the entire orchestra does not become more extreme.

  15. Simulator of the NUMAC SRMN module as virtual instrument for the personnel training of the LVNP

    International Nuclear Information System (INIS)

    Rojas S, A.S.; Rivero G, T.; Ruiz E, J.A.

    2006-01-01

    Inside the training programs of the personnel's of the Laguna Verde Nuclear power station (CNLV) Veracruz, Mexico, is necessary to carry out practices with instruments or electronic equipment contained inside the reactor instrumentation, most of these equipment are in operation and its can be part important of the safety system of the reactor, for what is sometimes impossible to carry out or to modify its operation conditions. The nuclear industry always has offered the improvement of the systems and equipment that compose the nuclear power station. In this context, during the last years, they have been carried out diverse upgrades of the systems in the CNLV, among them they are the dedicated measurement equipment and nuclear control (NUMAC, by its initials in English). It would be desirable to have a support tool that allows the interactive knowledge of these systems elevating by this way the quality of the personnel's preparation. In this work the NUMAC system by means of a virtual instrument, which has the facilities of developing practices and programs of training is presented. The NUMAC (Nuclear Measurement Analysis and Control), its are controllers connected to the SIIP (Integral System of Process Information), of the following types: RWM (Rod Worth Minimizer), LDM (Leak Detection Monitor), ATCU (Automatic TIP Control Unit [TIP: Traversing In-Core Probe]), LCR (Log Count Rate), LRM (Logarithmic Radiation Monitor), PRNM Power Range Neutron Monitor, SRNM (Start-up Range Neutron Monitor). The NUMAC, are instruments for monitoring and control of the reactor whose introduction is relatively recent, these instruments are connected to the SIIP, its are microprocessors similar to the industrial computers, dedicated to measure and to control systems in the plant. By safety, the control is programmed and it is configured locally in each processor and in the workstations of the SIIP, only the acquired information of these devices is presented. This work describes the

  16. Core-adjacent instrumentation systems for pebble bed reactors for process heat application - state of planning

    International Nuclear Information System (INIS)

    Benninghofen, G.; Serafin, N.; Spillekothen, H.G.; Hecker, R.; Brixy, H.; Serpekian, T.

    1982-06-01

    Planning and theoretical/experimental development work for core surveillance instrumentation systems is being performed to meet requirements of pebble bed reactors for process heat application. Detailed and proved instrumentation concepts are now available for the core-adjacent instrumentation systems. The current work and the results of neutron flux measurements at high temperatures are described. Operation devices for long-term accurate gas outlet temperature measurements up to approximately 1423 deg. K will also be discussed. (author)

  17. Instrumental and Vocal Teacher Education: Competences, Roles and Curricula

    Science.gov (United States)

    Lennon, Mary; Reed, Geoffrey

    2012-01-01

    This article focuses on selected outcomes of the European Association of Conservatoires (AEC) "Polifonia" Working Group for Instrumental and Vocal Teacher Training in Europe (2007-2010). The introduction provides the background to the project, explains the rationale and objectives, describes the research process and gives an overview of…

  18. XML for nuclear instrument control and monitoring: an approach towards standardisation

    International Nuclear Information System (INIS)

    Bharade, S.K.; Ananthakrishnan, T.S.; Kataria, S.K.; Singh, S.K.

    2004-01-01

    Communication among heterogeneous system with applications running under different operating systems and applications developed under different platforms has undergone rapid changes due to the adoption of XML standards. These are being developed for different industries like Chemical, Medical, Commercial etc. The High Energy Physics community has already a standard for exchange of data among different applications , under heterogeneous distributed systems like the CMS Data Acquisition System. There are a large number of Nuclear Instruments supplied by different manufactures which are increasingly getting connected. This approach is getting wider acceptance in instruments at reactor sites, accelerator sites and complex nuclear experiments -especially at centres like CERN. In order for these instruments to be able to describe the data which is available from them in a platform independent manner XML approach has been developed. This paper is the first attempt at Electronics Division for proposing an XML standard for control, monitoring, Data Acquisition and Analysis generated by Nuclear Instruments at Accelerator sites, Nuclear Reactor plant and Laboratory. The gamut of Nuclear Instruments include Multichannel Analysers, Health Physics Instruments, Accelerator Control Systems, Reactor Regulating systems, Flux mapping Systems etc. (author)

  19. Design concepts for a nuclear digital instrumentation and control system platform

    International Nuclear Information System (INIS)

    Ou, T. C.; Chen, C. K.; Chen, P. J.; Shyu, S. S.; Lee, C. L.; Hsieh, S. F.

    2010-10-01

    The objective of this paper is to present the development results of the nuclear instrumentation and control system in Taiwan. As the Taiwan nuclear power plants age, the need to consider upgrading of both their safety and non-safety-related instrumentation and control systems becomes more urgent. Meanwhile, the digital instrumentation and control system that is based on current fast evolving electronic and information technologies are difficult to maintain effectively. Therefore, Institute of Nuclear Energy Research was made a decision to promote the Taiwan Nuclear Instrumentation and Control System project to collaborate with domestic electronic industry to establish self-reliant capabilities on the design, manufacturing, and application of nuclear instrumentation and control systems with newer technology. In the case of safety-related applications like nuclear instrumentation and control, safety-oriented quality control is required. In order to establish a generic qualified digital platform, the world-wide licensing experience should be considered in the licensing process. This paper describes the qualification and certification tools by IEC 61508 for design and development of safety related equipment and explains the basis for many decisions made while performing the digital upgrade. (Author)

  20. The Treatment Effectiveness Assessment (TEA: an efficient, patient-centered instrument for evaluating progress in recovery from addiction

    Directory of Open Access Journals (Sweden)

    Ling W

    2012-12-01

    Full Text Available Walter Ling,1 David Farabee,1 Dagmar Liepa,2 Li-Tzy Wu31Integrated Substance Abuse Programs, University of California, Los Angeles, CA, USA; 2Valley Care Medical Center, Panorama City, CA, USA; 3Department of Psychiatry and Behavioral Sciences, School of Medicine, Duke University Medical Center, Durham, NC, USAAbstract: The fields of addiction medicine and addiction research have long sought an efficient yet comprehensive instrument to assess patient progress in treatment and recovery. Traditional tools are expensive, time consuming, complex, and based on topics that clinicians or researchers think are important. Thus, they typically do not provide patient-centered information that is meaningful and relevant to the lives of patients with substance use disorders. To improve our ability to understand patients’ progress in treatment from their perspectives, the authors and colleagues developed a patient-oriented assessment instrument that has considerable advantages over existing instruments: brevity, simplicity, ease of administration, orientation to the patient, and cost (none. The resulting Treatment Effectiveness Assessment (TEA elicits patient responses that help the patient and the clinician quickly gauge patient progress in treatment and in recovery, according to the patients’ sense of what is important within four domains established by prior research. Patients provide both numerical responses and representative details on their substance use, health, lifestyle, and community. No software is required for data entry or scoring, and no formal training is required to administer the TEA. This article describes the development of the TEA and the initial phases of its application in clinical practice and in research.Keywords: substance use disorders, global treatment progress, brief instrument, patient-centered