WorldWideScience

Sample records for instrumentation initiative activities

  1. 7-GeV Advanced Photon Source Instrumentation Initiative conceptual design report

    International Nuclear Information System (INIS)

    1992-12-01

    In this APS Instrumentation Initiative, 2.5-m-long and 5-m-long insertion-device x-ray sources will be built on 9 straight sections of the APS storage ring, and an additional 9 bending-magnet sources will also be put in use. The front ends for these 18 x-ray sources will be built to contain and safeguard access to these bright x-ray beams. In addition, funds will be provided to build state-of-the-art insertion-device beamlines to meet scientific and technological research demands well into the next century. This new initiative will also include four user laboratory modules and a special laboratory designed to meet the x-ray imaging research needs of the users. The Conceptual Design Report (CDR) for the APS Instrumentation Initiative describes the scope of all the above technical and conventional construction and provides a detailed cost and schedule for these activities. According to these plans, this new initiative begins in FY 1994 and ends in FY 1998. The document also describes the preconstruction R ampersand D plans for the Instrumentation Initiative activities and provides the cost estimates for the required R ampersand D

  2. Aquarius: The Instrument and Initial Results

    Science.gov (United States)

    Vine, David M Le; Lagerloef, G.S.E.; Ruf, C.; Wentz, F.; Yueh, S.; Piepmeier, J.; Lindstrom, E.; Dinnat, E.

    2012-01-01

    Aquarius was launched on June 10, 2011 aboard the Aquarius/SAC-D observatory and the instrument has been operating continuously since the initial turned-on was completed on August 25. The initial observed antenna temperatures were close to predicted and the first salinity map was released in September. In order to map the ocean salinity field, Aquarius includes several special features such as the inclusion of a scatterometer to provide a roughness correction, measurement of the third Stokes parameter to correct for Faraday rotation, and fast sampling to mitigate the effects of RFI. This paper provides an overview of the instrument and an example of initial results. Details are covered in subsequent papers in the session on Aquarius

  3. Rotary mode system initial instrument calibration

    International Nuclear Information System (INIS)

    Johns, B.R.

    1994-01-01

    The attached report contains the vendor calibration procedures used for the initial instrument calibration of the rotary core sampling equipment. The procedures are from approved vendor information files

  4. Instrumented Pipeline Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Thomas Piro; Michael Ream

    2010-07-31

    This report summarizes technical progress achieved during the cooperative agreement between Concurrent Technologies Corporation (CTC) and U.S. Department of Energy to address the need for a for low-cost monitoring and inspection sensor system as identified in the Department of Energy (DOE) National Gas Infrastructure Research & Development (R&D) Delivery Reliability Program Roadmap.. The Instrumented Pipeline Initiative (IPI) achieved the objective by researching technologies for the monitoring of pipeline delivery integrity, through a ubiquitous network of sensors and controllers to detect and diagnose incipient defects, leaks, and failures. This report is organized by tasks as detailed in the Statement of Project Objectives (SOPO). The sections all state the objective and approach before detailing results of work.

  5. EASY-An Instrument for Surveillance of Physical Activity in Youth.

    Science.gov (United States)

    Pate, Russell R; McIver, Kerry; Dowda, Marsha; Schenkelberg, Michaela A; Beets, Michael; DiStefano, Christine

    2018-01-23

    Physical activity (PA) promotion among youth is a public health priority and there is a need for robust surveillance systems to help support such initiatives. Existing youth PA self-report instruments that are used for surveillance lack information regarding the types and contexts of activity. Further, these instruments have limited validity with accelerometry. The purpose of the present study was to develop a self-report instrument, with sound psychometric properties, for monitoring compliance with PA guidelines in youth. In focus groups, 162 middle school students identified 30 forms of PA that are highly prevalent in that age group. We incorporated these activities into three preliminary forms of a self-report instrument. An independent sample of middle school students (n = 537) was randomly assigned to complete one of the three preliminary versions of the instrument. Rasch analysis was applied to the responses to the three formats, and a yes/no plus frequency format emerged as the preferred method. A third sample of 342 middle school students then completed the yes/no plus frequency instrument twice following a seven-day period during which they wore an accelerometer. Using both Rasch analysis and traditional correlational methods, validity and reliability of a 14-item instrument were established. Data were collected during 2012 - 2015. Spearman correlation coefficient for the association between the cumulative score for the 14 items and minutes per day of accelerometry-derived moderate-to-vigorous physical activity (MVPA) was 0.33 (95% CI 0.22, 0.43; pCommercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.

  6. [Development and validation of an instrument for initial nursing assessment].

    Science.gov (United States)

    Fernández-Sola, Cayetano; Granero-Molina, José; Mollinedo-Mallea, Judith; de Gonzales, María Hilda Peredo; Aguilera-Manrique, Gabriel; Ponce, Mara Luna

    2012-12-01

    The objective of this study, conducted in Bolivia from April to July of 2008, is the design and validation of an initial nursing assessment instrument to be used in clinical and educational environments in Santa Cruz (Bolivia). Twelve Bolivian nurses participated; both document analysis as well as consensus techniques were used to determine the categories and criteria to be assessed. Categories included in the nursing assessment instrument are a physical assessment and the eleven Gordon's Functional Health Patterns. The nursing assessment instrument stands out as being concise, easy to complete and utilizing a nursing approach. It does not include items for advanced nursing assessment. However, it incorporates items regarding lifestyle and the patient's autonomy. The nursing assessment instrument contributes to improving the quality of clinical records, supports the nursing diagnosis and implementation of the nursing process, promotes the nurse's role and helps to standardize practice.

  7. The PROactive instruments to measure physical activity in patients with chronic obstructive pulmonary disease

    Science.gov (United States)

    Gimeno-Santos, Elena; Raste, Yogini; Demeyer, Heleen; Louvaris, Zafeiris; de Jong, Corina; Rabinovich, Roberto A.; Hopkinson, Nicholas S.; Polkey, Michael I.; Vogiatzis, Ioannis; Tabberer, Maggie; Dobbels, Fabienne; Ivanoff, Nathalie; de Boer, Willem I.; van der Molen, Thys; Kulich, Karoly; Serra, Ignasi; Basagaña, Xavier; Troosters, Thierry; Puhan, Milo A.; Karlsson, Niklas

    2015-01-01

    No current patient-centred instrument captures all dimensions of physical activity in chronic obstructive pulmonary disease (COPD). Our objective was item reduction and initial validation of two instruments to measure physical activity in COPD. Physical activity was assessed in a 6-week, randomised, two-way cross-over, multicentre study using PROactive draft questionnaires (daily and clinical visit versions) and two activity monitors. Item reduction followed an iterative process including classical and Rasch model analyses, and input from patients and clinical experts. 236 COPD patients from five European centres were included. Results indicated the concept of physical activity in COPD had two domains, labelled “amount” and “difficulty”. After item reduction, the daily PROactive instrument comprised nine items and the clinical visit contained 14. Both demonstrated good model fit (person separation index >0.7). Confirmatory factor analysis supported the bidimensional structure. Both instruments had good internal consistency (Cronbach's α>0.8), test–retest reliability (intraclass correlation coefficient ≥0.9) and exhibited moderate-to-high correlations (r>0.6) with related constructs and very low correlations (r<0.3) with unrelated constructs, providing evidence for construct validity. Daily and clinical visit “PROactive physical activity in COPD” instruments are hybrid tools combining a short patient-reported outcome questionnaire and two activity monitor variables which provide simple, valid and reliable measures of physical activity in COPD patients. PMID:26022965

  8. Diverse Portfolio of Scientific Instrumentation Initiatives of the Deep Carbon Observatory

    Science.gov (United States)

    Schiffries, Craig; Hazen, Robert; Hemley, Russell; Mangum, Andrea

    2016-04-01

    Advances in scientific instrumentation are important drivers of scientific discovery. The Deep Carbon Observatory (DCO) supports a diverse portfolio of scientific instrumentation initiatives worldwide as part of its ten-year quest to achieve a transformational understanding of the quantities, movements, origins, and forms of Earth's deep carbon. Substantial progress has been made in the development of a wide range of instruments, including: • Quantum cascade laser-infrared absorption spectrometer for clumped methane isotope thermometry (Shuhei Ono) • Large-radius high-mass-resolution multiple-collector isotope ratio mass spectrometer for analysis of rare isotopologues of methane and other gases (Edward Young, Douglas Rumble) • Volcanic field deployment of the laser isotope ratio-meter (Damien Weidmann) • Novel large-volume diamond anvil cell for neutron scattering (Malcolm Guthrie, Reinhard Boehler) • Novel synchrotron x-ray probes for deep carbon (Wendy Mao) • Ultrafast laser instrument for in situ measurements of elastic, electronic, and transport properties of carbon-bearing fluids and crystalline materials (Alexander Goncharov) • Combined instrument for molecular imaging in geochemistry (Andrew Steele) • Pressurized Underwater Sample Handler (Isabelle Daniel, Karyn Rogers) These and other DCO instrumentation projects are highly leveraged investments involving a large number of sponsors, partners, and collaborators.

  9. Comparison of instrumental neutron activation analysis and instrumental charged-particle activation analysis for determining of Zn-68 abundance

    International Nuclear Information System (INIS)

    Rafii, H.; Mirzaei, M.; Aslani, G.R.; Kamali-Dehghan, M.; Rajamand, A-A.; Rahiminejad, A.; Mirzajani, N.; Sardari, D.; Shahabi, I.; Majidi, F.

    2004-01-01

    Gallium-67 has found important applications in nuclear medicine since last decades. The bombardment of enriched zinc-68 by proton beams in cyclotron is the most suitable method for the carrier-free production of this radionuclide. Any traces and isotopic impurities of the target cause serious radiological hazards because of their associated induced radioactivities. Trace analysis and Zn-68 content determination of the target material before any bombardment and chemical separation provide a valuable assessment of desired product. The elemental abundance evaluation of enriched isotopes is generally carried out by inductively coupled plasma-mass spectrometry method, ICP-Ms Instrumental neutron activation analysis and instrumental charged particle activation analysis. International neutron activation analysis and instrumental charged- particle activation analysis, looks be an alternative nuclear method for determining the abundance evaluation of enriched Zn-68 enrichment in two different samples has been studied by mean of international neutron activation analysis and instrumental charged- particle activation analysis . One sample was purchased from a French company, cortecnet, and the other was separated by an electromagnetic system in the Ions source department of our center, NRCAM. The neutron or proton irradiation was took place respectively in miniature neutron source reactor of Esfahan by flux of (1 to 5) 10 11 n/cm 2 .sec for 30 min and in Cyclon30 by 19 MeV proton beams of 100μA current for 12 min. The produced radioactivity was measured by HpGe detector for determination of trace impurities and evaluation of Zn-68 content in the samples. The result shows a good agreement with the reported ones by their producers and their low derivation of about ± indicates that the international neutron activation analysis and instrumental charged- particle activation analysis are relatively precise and rapid and each one can be used as a supplemental method for analyzing

  10. Project W-314 DST and DCRT instrument and control systems, initial assessment

    International Nuclear Information System (INIS)

    Acree, C.D.

    1996-01-01

    This report contains an assessment of the instrument and control systems in the Double Shell Tank Farms and the 244-A DCRT. The assessment report contains data from physical inspection activities and an overall engineering assessment of the instruments and control systems in use in the Double Shell Tanks

  11. Instrument pre-development activities for FLEX

    Science.gov (United States)

    Pettinato, L.; Fossati, E.; Coppo, P. M.; Taiti, A.; Labate, D.; Capanni, A.; Taccola, M.; Bézy, J. L.; Francois, M.; Meynart, R.; Erdmann, L.; Triebel, P.

    2017-09-01

    The FLuorescence Imaging Spectrometer (FLORIS) is the payload of the FLuorescence Explorer Mission (FLEX) of the European Space Agency. The mission objective is to perform quantitative measurements of the solar induced vegetation fluorescence to monitor photosynthetic activity. FLORIS works in a push-broom configuration and it is designed to acquire data in the 500-780 nm spectral range, with a sampling of 0.1 nm in the oxygen bands (759-769 nm and 686- 697 nm) and 0.5-2.0 nm in the red edge, chlorophyll absorption and Photochemical Reflectance Index bands. FLEX will fly in formation with Sentinel-3 to benefit of the measurements made by the Sentinel-3 instruments OLCI and SLSTR, particularly for cloud screening, proper characterization of the atmospheric state and determination of the surface temperature. The instrument concept is based on a common telescope and two modified Offner spectrometers with reflective concave gratings both for the High Resolution (HR) and Low Resolution (LR) spectrometers. In the frame of the instrument pre-development Leonardo Company (I) has built and tested an elegant breadboard of the instrument consisting of the telescope and the HR spectrometer. The development of the LR spectrometer is in charge of OHB System AG (D) and is currently in the manufacturing phase. The main objectives of the activity are: anticipate the development of the instrument and provide early risk retirement of critical components, evaluate the system performances such as imaging quality parameters, straylight, ghost, polarization sensitivity and environmental influences, verify the adequacy of critical tests such as spectral characterization and straylight, define and optimize instrument alignment procedures. Following a brief overview of the FLEX mission, the paper will cover the design and the development of the optics breadboard with emphasis on the results obtained during the tests and the lessons learned for the flight unit.

  12. Work group I: Measures of the food and physical activity environment: instruments.

    Science.gov (United States)

    Saelens, Brian E; Glanz, Karen

    2009-04-01

    A work group was convened to identify the core challenges, content gaps, and corresponding possible solutions for improving food- and physical activity-environment instrumentation. Identified challenges included instrument proliferation, the scaling or grain of instruments and appropriate aggregation to the neighborhood or community level, and unknown sensitivity to change of most instruments. Solutions for addressing these challenges included establishing an interactive and real-time instrument repository, developing and enforcing high standards for instrument reporting, increasing community-researcher collaborations, and implementing surveillance of food and physical activity environment. Solid instrumentation will accelerate a better understanding of food- and physical activity-environment effects on eating and physical activity behaviors.

  13. Development of α and/or β activity aerosol instrumentation

    International Nuclear Information System (INIS)

    Lu Zhengyong; Li Aiwu; Gou Quanlu

    1996-01-01

    A radioactive aerosol instrumentation is developed recently for measuring the α and/or β activity of artificial radioactivity aerosols which are produced in nuclear facilities. The instrumentation has the function discriminating natural radioactivity aerosols resulted from radon and thoron daughters, and it is enabled in time and without delay to measure α and β artificial activity collected with a filter by pumping aerosols through this filter. The energy discrimination and compensation method is used for eliminating the influence of natural αradioactivity aerosols. To minimize the influence of natural β-radioactivity aerosols, the method measuring the ratio α/β of natural aerosols is also used in the instrument. The improved methods eliminating the influence of natural background α and β aerosols are used so that both α and β artificial activities in aerosol filter samples can be monitored simultaneously. The instrumentation is appropriate for monitoring α and/or β artificial radioactive aerosols

  14. Instrumental activation analysis of molybdenites

    International Nuclear Information System (INIS)

    Geisler, M.; Schelhorn, H.

    1981-01-01

    Na, K, Sc, Cr, Fe, Co, Se, Rb, Ag, Cs, Ba, La, Ce, Eu, Yb, Hf, W, Re, and Th have been determined in 6 molybdenite samples by instrumental activation analysis. The samples were of different origin and showed K, Sc, W, and Re values with differences of more than two orders of magnitude, whereas Sc values were within one order of magnitude

  15. Utilisation and performance of sodium instrumentation during start-up and initial operation of Phenix

    International Nuclear Information System (INIS)

    Lions, N.; Buis, H.; Baron, J.; Fournier, C.; Gourdon, J.

    1976-01-01

    The main process-instruments on the Phenix reactor are presented with the exception of the FFDL System and of the hydrogen-detector which are described in other papers. The results obtained during reactor start-up and during initial operation of the nuclear power-station are given [fr

  16. Performance tests for instruments measuring radon activity concentration

    International Nuclear Information System (INIS)

    Beck, T.R.; Buchroeder, H.; Schmidt, V.

    2009-01-01

    Performance tests of electronic instruments measuring the activity concentration of 222 Rn have been carried out with respect to the standard IEC 61577-2. In total, 9 types of instrument operating with ionization chambers or electrostatic collection have been tested for the influence of different climatic and radiological factors on the measurement characteristics. It is concluded that all types of instrument, which are commercially available, are suitable for indoor radon measurements. Because of the dependence on climatic conditions, the outdoor use is partly limited.

  17. Conference on instrumental activation analysis IAA 92

    International Nuclear Information System (INIS)

    Frana, J.; Obrusnik, I.

    1992-05-01

    The publication contains 26 abstracts primarily concerned with neutron activation analysis, although other analytical techniques based on X-ray fluorescence analysis, PIXE, PIGE, RBS are also included. Some contributions deal with aspects of quality practice and assurance in radioanalytical laboratories, with marketing of instrumental neutron activation analysis services, with hard- and software aspects of radiation detection, etc. (Z.S.)

  18. Design of and initial results from a Highly Instrumented Reactor for Atmospheric Chemistry (HIRAC

    Directory of Open Access Journals (Sweden)

    D. R. Glowacki

    2007-10-01

    Full Text Available The design of a Highly Instrumented Reactor for Atmospheric Chemistry (HIRAC is described and initial results obtained from HIRAC are presented. The ability of HIRAC to perform in-situ laser-induced fluorescence detection of OH and HO2 radicals with the Fluorescence Assay by Gas Expansion (FAGE technique establishes it as internationally unique for a chamber of its size and pressure/temperature variable capabilities. In addition to the FAGE technique, HIRAC features a suite of analytical instrumentation, including: a multipass FTIR system; a conventional gas chromatography (GC instrument and a GC instrument for formaldehyde detection; NO/NO2, CO, O3, and H2O vapour analysers. Ray tracing simulations and NO2 actinometry have been utilized to develop a detailed model of the radiation field within HIRAC. Comparisons between the analysers and the FTIR coupled to HIRAC have been performed, and HIRAC has also been used to investigate pressure dependent kinetics of the chlorine atom reaction with ethene and the reaction of O3 and t-2-butene. The results obtained are in good agreement with literature recommendations and Master Chemical Mechanism predictions. HIRAC thereby offers a highly instrumented platform with the potential for: (1 high precision kinetics investigations over a range of atmospheric conditions; (2 detailed mechanism development, significantly enhanced according to its capability for measuring radicals; and (3 field instrument intercomparison, calibration, development, and investigations of instrument response at a range of atmospheric conditions.

  19. Validation of the force and frequency characteristics of the activator adjusting instrument: effectiveness as a mechanical impedance measurement tool.

    Science.gov (United States)

    Keller, T S; Colloca, C J; Fuhr, A W

    1999-02-01

    To determine the dynamic force-time and force-frequency characteristics of the Activator Adjusting Instrument and to validate its effectiveness as a mechanical impedance measurement device; in addition, to refine or optimize the force-frequency characteristics of the Activator Adjusting Instrument to provide enhanced dynamic structural measurement reliability and accuracy. An idealized test structure consisting of a rectangular steel beam with a static stiffness similar to that of the human thoracolumbar spine was used for validation of a method to determine the dynamic mechanical response of the spine. The Activator Adjusting Instrument equipped with a load cell and accelerometer was used to measure forces and accelerations during mechanical excitation of the steel beam. Driving point and transfer mechanical impedance and resonant frequency of the beam were determined by use of a frequency spectrum analysis for different force settings, stylus masses, and stylus tips. Results were compared with beam theory and transfer impedance measurements obtained by use of a commercial electronic PCB impact hammer. The Activator Adjusting Instrument imparted a very complex dynamic impact comprising an initial high force (116 to 140 N), short duration pulse (analysis of the Activator Adjusting Instrument impulse indicated that the Activator Adjusting Instrument has a variable force spectrum and delivers its peak energy at a frequency of 20 Hz. Added masses and different durometer stylus tips had very little influence on the Activator Adjusting Instrument force spectrum. The resonant frequency of the beam was accurately predicted by both the Activator Adjusting Instrument and electronic PCB impact hammer, but variations in the magnitude of the driving point impedance at the resonant frequency were high (67%) compared with the transfer impedance measurements obtained with the electronic PCB impact hammer, which had a more uniform force spectrum and was more repeatable (frequency

  20. Energetic neutral atom imaging with the Polar CEPPAD/IPS instrument: Initial forward modeling results

    International Nuclear Information System (INIS)

    Henderson, M.G.; Reeves, G.D.; Moore, K.R.; Spence, H.E.; Jorgensen, A.M.; Roelof, E.C.

    1997-01-01

    Although the primary function of the CEP-PAD/IPS instrument on Polar is the measurement of energetic ions in-situ, it has also proven to be a very capable Energetic neutral Atom (ENA) imager. Raw ENA images are currently being constructed on a routine basis with a temporal resolution of minutes during both active and quiet times. However, while analyses of these images by themselves provide much information on the spatial distribution and dynamics of the energetic ion population in the ring current, detailed modeling is required to extract the actual ion distributions. In this paper, the authors present the initial results of forward modeling an IPS ENA image obtained during a small geo-magnetic storm on June 9, 1997. The equatorial ion distribution inferred with this technique reproduces the expected large noon/midnight and dawn/dusk asymmetries. The limitations of the model are discussed and a number of modifications to the basic forward modeling technique are proposed which should significantly improve its performance in future studies

  1. Instrumental neutron activation analysis - a routine method

    International Nuclear Information System (INIS)

    Bruin, M. de.

    1983-01-01

    This thesis describes the way in which at IRI instrumental neutron activation analysis (INAA) has been developed into an automated system for routine analysis. The basis of this work are 20 publications describing the development of INAA since 1968. (Auth.)

  2. Evaluation of a draft standard on performance specifications for health physics instrumentation. Initial results for radiological tests

    International Nuclear Information System (INIS)

    Swinth, K.L.; Kenoyer, J.L.; Mileham, A.P.; Kathren, R.L.; Selby, J.M.

    1983-06-01

    The draft ANSI standard N42.17D2 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. The primary objective of the project is the evaluation of the applicability and practicality of the proposed standard through testing of a cross-section of currently available commercial instruments to determine how well they conform to the standard. The standard is being tested against instruments such as ionization chambers, G.M. detectors, alpha survey meters, and neutron dose equivalent survey meters. This paper presents results of the preliminary radiological performance tests on ionization chambers and G.M. detectors. This includes both the data generated during the tests and a discussion of procedures developed to perform the testing. Results are reported for response time, accuracy, precision, radiation overloads, and angular dependence. In addition, results are reported for parameters that affect instrument performance including battery lifetime, geotropism and stability. Initial test indicates that some of the instruments will not meet the criteria specified in ANSI N42.17D2. Results cover approximately 40 instruments that have been obtained by direct purchase, by loan from instrument vendors or by loan from others including DOE licensees

  3. UAVSAR Program: Initial Results from New Instrument Capabilities

    Science.gov (United States)

    Lou, Yunling; Hensley, Scott; Moghaddam, Mahta; Moller, Delwyn; Chapin, Elaine; Chau, Alexandra; Clark, Duane; Hawkins, Brian; Jones, Cathleen; Marks, Phillip; hide

    2013-01-01

    UAVSAR is an imaging radar instrument suite that serves as NASA's airborne facility instrument to acquire scientific data for Principal Investigators as well as a radar test-bed for new radar observation techniques and radar technology demonstration. Since commencing operational science observations in January 2009, the compact, reconfigurable, pod-based radar has been acquiring L-band fully polarimetric SAR (POLSAR) data with repeat-pass interferometric (RPI) observations underneath NASA Dryden's Gulfstream-III jet to provide measurements for science investigations in solid earth and cryospheric studies, vegetation mapping and land use classification, archaeological research, soil moisture mapping, geology and cold land processes. In the past year, we have made significant upgrades to add new instrument capabilities and new platform options to accommodate the increasing demand for UAVSAR to support scientific campaigns to measure subsurface soil moisture, acquire data in the polar regions, and for algorithm development, verification, and cross-calibration with other airborne/spaceborne instruments.

  4. Conference on instrumental activation analysis - IAA 89

    International Nuclear Information System (INIS)

    Vobecky, M.; Obrusnik, I.

    1989-05-01

    The proceedings contain 40 abstracts of papers all of which have been incorporated in INIS. The papers were centred on the applications of radioanalytical methods, especialy on neutron activation analysis, X-ray fluorescence analysis, PIXE analysis and tracer techniques in biology, medicine and metallurgy, measuring instruments including microcomputers, and data processing methods. (J.P.)

  5. An Intelligent Hand-Held Microsurgical Instrument for Improved Accuracy

    National Research Council Canada - National Science Library

    Ang, Wei

    2001-01-01

    This paper presents the development and initial experimental results of the first prototype of Micron, an active hand-held instrument to sense and compensate physiological tremor and other unwanted...

  6. An instrumentation for control and measurement of activated mineral samples

    International Nuclear Information System (INIS)

    Skaarup, P.

    1976-01-01

    A description is given of an instrumentation for control of a pneumatic tube system used to transport mineral samples for activation in a reactor and from there to a detector arrangement. A possible content of uranium in the samples can be seen from the radiation measured. The instrumentation includes a PDP-11 computer and a CAMAC crate

  7. Radiochemical and instrumental neutron activation analysis - recent trends

    International Nuclear Information System (INIS)

    Dams, R.

    1990-01-01

    Recent trends of radiochemical and instrumental neutron activation analysis are discussed. Novel developments include the application of cyclic and pulsed activation, better energy resolution with hyperpure germanium detectors, and use of pulse processing systems allowing extremely high count rates of very short-lived isotopes. Further development is anticipated in the field of speciation in biological and environmental studies. Radiochemical methods have led to accurate determinations at the ng/g level. A promising future is expected for neutron activation techniques. (orig.)

  8. Incidence of apical crack initiation and propagation during the removal of root canal filling material with ProTaper and Mtwo rotary nickel-titanium retreatment instruments and hand files.

    Science.gov (United States)

    Topçuoğlu, Hüseyin Sinan; Düzgün, Salih; Kesim, Bertan; Tuncay, Oznur

    2014-07-01

    The aim of this study was to determine the incidence of crack initiation and propagation in apical root dentin after retreatment procedures performed by using 2 rotary retreatment systems and hand files with additional instrumentation. Eighty extracted mandibular premolars with single canals were selected. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the control group, and no preparation was performed. The remaining 60 teeth were prepared to size 35 with rotary files and filled with gutta-percha and AH Plus sealer. Specimens were then divided into 3 groups (n = 20), and retreatment procedures were performed with the following devices and techniques: ProTaper Universal retreatment files, Mtwo retreatment files, and hand files. After retreatment, the additional instrumentation was performed by using size 40 ProTaper, Mtwo, and hand files. Digital images of the apical root surface were recorded before preparation, after instrumentation, after filling, after retreatment, and after additional instrumentation. The images were then inspected for the presence of any new apical cracks and propagation. Data were analyzed with the logistic regression and Fisher exact tests. All experimental groups caused crack initiation and propagation after use of retreatment instruments. The ProTaper and Mtwo retreatment groups caused greater crack initiation and propagation than the hand instrument group (P ProTaper and Mtwo instruments after the use of retreatment instruments caused crack initiation and propagation, whereas hand files caused neither crack initiation nor propagation (P < .05). This study showed that retreatment procedures and additional instrumentation after the use of retreatment files may cause crack initiation and propagation in apical dentin. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. The Community College Survey of Men: An Initial Validation of the Instrument's Non-Cognitive Outcomes Construct

    Science.gov (United States)

    Wood, J. \\Luke; Harris, Frank, III.

    2013-01-01

    The purpose of this manuscript is to discuss the utility of the Community College Survey of Men (CCSM[c]), an instrument designed to examine predictors of student success for men in community colleges. The authors highlight initial validation results from a recent pilot of the CCSM[c], with a focus on the non-cognitive outcomes construct employed…

  10. Optimization of instrumental activation analysis conditions

    International Nuclear Information System (INIS)

    Guinn, V.; Gavrilas-Guinn, M.

    1993-01-01

    In instrumental neutron activation analysis (INAA) work, a good commonsense rule of thumb is that the opium conditions for the measurement of any induced activity, in a multi-element sample matrix, are an irradiation time, a decay time, and a counting time each approximately equal to the half-life of the radionuclide (if feasible). The INAA Advance Computer Program (APCP) was used to test this rule on ten reference materials. For the 280 radionuclide/material combinations traced through all 14 APCP condition sets, the rule predicted the best set for 67% of them, was off by one set for 31% of them, and was only off by two sets of 2% of them. (author) 6 refs.; 1 fig.; 3 tabs

  11. The determination of some impurities in zirconium metal by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Eddy, B.T.; Pearton, D.C.G.; Watterson, J.J.

    1976-01-01

    This report describes the work done on the development of an instrumental neutron-activation method for the analysis of impurities in reactor-grade zirconium. Nine samples were analysed, and the results were compared with those obtained by other techniques. No statistically significant differences were observed for ten of the twelve elements that could possibly be determined by instrumental neutron-activation analysis. Cadmium cannot be determined at the 0,5 p.p.m. level, and there is doubt about the comparative values recorded for aluminium. The precision of the measurement by direct instrumental neutron-activation analysis ranges from 1,4 per cent for tungsten to 17 per cent for chromium [af

  12. Active instrumental guidance in interventional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Wildermuth, S.; Erhart, P.; Leung, D.A.; Goehde, S.; Schoenenberger, A.; Debatin, J.F.

    1998-01-01

    Purpose: An active MR-based guidance system for visualisation of invasive instruments is described. Methods: The principle of MR tracking is based on the integration of a miniaturised coil into the tip of the instrument itself. A phantom experiment was designed to demonstrate the localising accuracy of this technique. In [dition, bicompatibility and warming effects were evaluated. Preliminary intravascular applications that were performed in animal experiments under MR guidance included embolisation, vascular occlusion as well as transjugular intrahepatic punctures. Percutaneous biopsies, cholecystostomies and laparoscopic applications were also evaluated with MR tracking. Results: Phantom experiments confirmed an excellent localisation accuracy of MR tracking compared to conventional r[iography. At a field strength of 0.5 T, the temperature increase remained below 2 C. Results of phantom experiments revealed a potential of significant heating dependent on the sequence parameters employed. MR tracking allowed a robust, simultaneously biplanar visualisation of the instrument tips in real time. Based on MR 'ro[ map' images, various intravascular and percutaneous interventions were successfully performed in vivo under MR guidance. Conclusions: MR tracking is a flexible concept permitting monitoring in the guidance of instruments in an MR environment. Various preliminary in vitro and in vivo experiments demonstrate safety, localisation accuracy and feasibility of this biplanar localisation technique in real time. (orig.) [de

  13. Initial development and psychometric testing of an instrument to measure the quality of children's end-of-life care.

    Science.gov (United States)

    Widger, Kimberley; Tourangeau, Ann E; Steele, Rose; Streiner, David L

    2015-01-01

    The field of pediatric palliative care is hindered by the lack of a well-defined, reliable, and valid method for measuring the quality of end-of-life care. The study purpose was to develop and test an instrument to measure mothers' perspectives on the quality of care received before, at the time of, and following a child's death. In Phase 1, key components of quality end-of-life care for children were synthesized through a comprehensive review of research literature. These key components were validated in Phase 2 and then extended through focus groups with bereaved parents. In Phase 3, items were developed to assess structures, processes, and outcomes of quality end-of-life care then tested for content and face validity with health professionals. Cognitive testing was conducted through interviews with bereaved parents. In Phase 4, bereaved mothers were recruited through 10 children's hospitals/hospices in Canada to complete the instrument, and psychometric testing was conducted. Following review of 67 manuscripts and 3 focus groups with 10 parents, 141 items were initially developed. The overall content validity index for these items was 0.84 as rated by 7 health professionals. Based on feedback from health professionals and cognitive testing with 6 parents, a 144-item instrument was finalized for further testing. In Phase 4, 128 mothers completed the instrument, 31 of whom completed it twice. Test-retest reliability, internal consistency, and construct validity were demonstrated for six subscales: Connect With Families, Involve Parents, Share Information With Parents, Share Information Among Health Professionals, Support Parents, and Provide Care at Death. Additional items with content validity were grouped in four domains: Support the Child, Support Siblings, Provide Bereavement Follow-up, and Structures of Care. Forty-eight items were deleted through psychometric testing, leaving a 95-item instrument. There is good initial evidence for the reliability and

  14. The healthy afterschool activity and nutrition documentation instrument.

    Science.gov (United States)

    Ajja, Rahma; Beets, Michael W; Huberty, Jennifer; Kaczynski, Andrew T; Ward, Dianne S

    2012-09-01

    Policies call on afterschool programs to improve the physical activity and nutrition habits of youth attending. No tool exists to assess the extent to which the afterschool program environment meets physical activity and nutrition policies. To describe the development of the Healthy Afterschool Activity and Nutrition Documentation (HAAND) instrument, which consists of two subscales: Healthy Afterschool Program Index for Physical Activity (HAPI-PA) and the HAPI-Nutrition (HAPI-N). Thirty-nine afterschool programs took part in the HAAND evaluation during fall/spring 2010-2011. Inter-rater reliability data were collected at 20 afterschool programs during a single site visit via direct observation, personal interview, and written document review. Validity of the HAPI-PA was established by comparing HAPI-PA scores to pedometer steps collected in a subsample of 934 children attending 25 of the afterschool programs. Validity of the HAPI-N scores was compared against the mean number of times/week that fruits and vegetables (FV) and whole grains were served in the program. Data were analyzed in June/July 2011. Inter-rater percent agreement was 85%-100% across all items. Increased pedometer steps were associated with the presence of a written policy related to physical activity, amount/quality of staff training, use of a physical activity curriculum, and offering activities that appeal to both genders. Higher servings of FV and whole grains per week were associated with the presence of a written policy regarding the nutritional quality of snacks. The HAAND instrument is a reliable and valid measurement tool that can be used to assess the physical activity and nutritional environment of afterschool programs. Copyright © 2012 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  15. Microprocessor-controlled data-acquisition instrument for neutron-activation measurements

    International Nuclear Information System (INIS)

    Jones, B.A.

    1981-01-01

    This paper describes a microprocessor controlled data acquisition instrument designed at Lawrence Livermore National Laboratory to provide experimenters with a diagnostic tool for measuring the performance of laser imploded fusion targets via neutron activation techniques. This instrument features the ability to count four independent inputs simultaneously while providing a front panel readout of these inputs, plus a time of day clock. A hardcopy printout of the data is also provided by a built-in thermal printer. All running modes and parameters are user selectable via a front panel keypad, and a complete set of internal self-testing diagnostics are available for debug

  16. Instrumental neutron activation analysis in environmental studies of trace elements

    International Nuclear Information System (INIS)

    Salmon, L.

    1975-06-01

    The application of a routine instrumental nuclear method is described in relation to environmental surveys and studies. A working rather than formal review is made of the techniques applied with particular reference to the data processing methods involved. The elements measured by instrumental activation analysis were: Ag, Al, As, Au, Ba, Br, Ca, Ce, Cl, Cd, Co, Cr, Cs, Cu, Fe, Hg, I, In, La, Mn, Na, Ni, Pb, Rb, Sb, Sc, Se, Th, Ti, U, V, W, Zn. (author)

  17. Cascadia Initiative Ocean Bottom Seismograph Performance

    Science.gov (United States)

    Evers, B.; Aderhold, K.

    2017-12-01

    The Ocean Bottom Seismograph Instrument Pool (OBSIP) provided instrumentation and operations support for the Cascadia Initiative community experiment. This experiment investigated geophysical processes across the Cascadia subduction zone through a combination of onshore and offshore seismic data. The recovery of Year 4 instruments in September 2015 marked the conclusion of a multi-year experiment that utilized 60 ocean-bottom seismographs (OBSs) specifically designed for the subduction zone boundary, including shallow/deep water deployments and active fisheries. The new instruments featured trawl-resistant enclosures designed by Lamont-Doherty Earth Observatory (LDEO) and Scripps Institution of Oceanography (SIO) for shallow deployment [water depth ≤ 500 m], as well as new deep-water instruments designed by Woods Hole Oceanographic Institute (WHOI). Existing OBSIP instruments were also deployed along the Blanco Transform Fault and on the Gorda Plate through complementary experiments. Station instrumentation included weak and strong motion seismometers, differential pressure gauges (DPG) and absolute pressure gauges (APG). All data collected from the Cascadia, Blanco, and Gorda deployments is available through the Incorporated Research Institutions for Seismology (IRIS) Data Management Center (DMC). The Cascadia Initiative is the largest amphibious seismic experiment undertaken to date, encompassing a diverse technical implementation and demonstrating an effective structure for community experiments. Thus, the results from Cascadia serve as both a technical and operational resource for the development of future community experiments, such as might be contemplated as part of the SZ4D Initiative. To guide future efforts, we investigate and summarize the quality of the Cascadia OBS data using basic metrics such as instrument recovery and more advanced metrics such as noise characteristics through power spectral density analysis. We also use this broad and diverse

  18. Second Chandra Instrument Activated August 28

    Science.gov (United States)

    1999-08-01

    Cambridge, MA--NASA's Chandra X-ray Observatory opened a new era in astronomy Saturday, August 28, by making the most precise measurements ever recorded of the energy output from the 10 million degree corona of a star. Last weekend's observations came after the successful activation of an instrument developed by MIT that will allow a one-thousand-fold improvement in the capability to measure X-ray spectra from space. The new measurements, made with the High Energy Transmission Grating Spectrometer, join spectacular images taken last week by Chandra of the aftermath of a gigantic stellar explosion. The spectrometer is one of four key instruments aboard Chandra, and the second to be activated. The others will be turned on over the next two weeks. The spectrometer activated yesterday spreads the X-rays from Chandra's mirrors into a spectrum, much as a prism spreads light into its colors. The spectrum then can be read by Chandra's imaging detectors like a kind of cosmic bar code from which scientists can deduce the chemical composition and temperature of the corona. A corona is a region of hot gas and magnetic loops that extend hundreds of thousands of miles above the star's visible surface and is best studied with X-rays. "The success of the new spectrometer is definitely a major milestone for modern astronomy," said MIT Professor Claude R. Canizares, principal investigator for the instrument and associate director of the Chandra X-ray Observatory Center (CXC). "Within the first hour we had obtained the best X-ray spectrum ever recorded for a celestial source. We can already see unexpected features that will teach us new things about stars and about matter at high temperatures." The spectrometer measured X-rays from the star Capella, which is 40 light years away in the constellation Auriga. Capella is actually two stars orbiting one another and possibly interacting in ways that pump extra heat into the corona, which appears more active than that of the Sun. How a star

  19. The relation between instrumental musical activity and cognitive aging.

    Science.gov (United States)

    Hanna-Pladdy, Brenda; MacKay, Alicia

    2011-05-01

    Intensive repetitive musical practice can lead to bilateral cortical reorganization. However, whether musical sensorimotor and cognitive abilities transfer to nonmusical cognitive abilities that are maintained throughout the life span is unclear. In an attempt to identify modifiable lifestyle factors that may potentially enhance successful aging, we evaluated the association between musical instrumental participation and cognitive aging. Seventy older healthy adults (ages 60-83) varying in musical activity completed a comprehensive neuropsychological battery. The groups (nonmusicians, low and high activity musicians) were matched on age, education, history of physical exercise, while musicians were matched on age of instrumental acquisition and formal years of musical training. Musicians were classified in the low (1-9 years) or high (>10 years) activity group based on years of musical experience throughout their life span. The results of this preliminary study revealed that participants with at least 10 years of musical experience (high activity musicians) had better performance in nonverbal memory (η2 = .106), naming (η2 = .103), and executive processes (η2 = .131) in advanced age relative to nonmusicians. Several regression analyses evaluated how years of musical activity, age of acquisition, type of musical training, and other variables predicted cognitive performance. These correlational results suggest a strong predictive effect of high musical activity throughout the life span on preserved cognitive functioning in advanced age. A discussion of how musical participation may enhance cognitive aging is provided along with other alternative explanations.

  20. Active Radiation Level Measurement on New Laboratory Instrument for Evaluating the Antibacterial Activity of Radioisotope

    International Nuclear Information System (INIS)

    Joh, Eunha; Park, Jang Guen

    2014-01-01

    A disc method has been widely used to measure the antibacterial effect of chemical agents. However, it is difficult to measure the antibacterial effect of radioisotopes using a disc method. A disc method is a method for diffusing a drug by placing the drug containing disc on the medium. In this method, radioisotopes are diffused on the medium and it is difficult to measure the exact effect by radiation. Thus, new laboratory equipment needs to evaluate the antibacterial activity by the radioisotopes. In this study, we measured the radiation level of radioisotopes on a new laboratory instrument using a MCNP. A disc method has been widely used to measure the antibacterial effect of chemical agents. This method uses a drug diffusion system for the measurement of anti-bacterial antibiotics. To measure the antimicrobial activity of a radioisotope, a new type of laboratory instrument is necessary to prevent the drug from spreading. The radioisotopes are used to diagnose and treat cancer. However, studies for anti-biotical use have not progressed. The radiation of radioisotopes has the effect of killing bacteria. Before this study proceeds further, it is necessary to be able to measure the antimicrobial activity of the radioisotope easily in the laboratory. However, in this study, it was possible to measure the antimicrobial activity of the radioisotope in the laboratory using a new laboratory instrument. We intend to start evaluation studies of the antibacterial activity of specific radioisotopes. In addition, it will be possible to develop research to overcome diseases caused by bacteria in the future

  1. Active Radiation Level Measurement on New Laboratory Instrument for Evaluating the Antibacterial Activity of Radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Joh, Eunha; Park, Jang Guen [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    A disc method has been widely used to measure the antibacterial effect of chemical agents. However, it is difficult to measure the antibacterial effect of radioisotopes using a disc method. A disc method is a method for diffusing a drug by placing the drug containing disc on the medium. In this method, radioisotopes are diffused on the medium and it is difficult to measure the exact effect by radiation. Thus, new laboratory equipment needs to evaluate the antibacterial activity by the radioisotopes. In this study, we measured the radiation level of radioisotopes on a new laboratory instrument using a MCNP. A disc method has been widely used to measure the antibacterial effect of chemical agents. This method uses a drug diffusion system for the measurement of anti-bacterial antibiotics. To measure the antimicrobial activity of a radioisotope, a new type of laboratory instrument is necessary to prevent the drug from spreading. The radioisotopes are used to diagnose and treat cancer. However, studies for anti-biotical use have not progressed. The radiation of radioisotopes has the effect of killing bacteria. Before this study proceeds further, it is necessary to be able to measure the antimicrobial activity of the radioisotope easily in the laboratory. However, in this study, it was possible to measure the antimicrobial activity of the radioisotope in the laboratory using a new laboratory instrument. We intend to start evaluation studies of the antibacterial activity of specific radioisotopes. In addition, it will be possible to develop research to overcome diseases caused by bacteria in the future.

  2. Practical considerations in instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Ahmad, N.

    2001-01-01

    Activation analysis is a technique of elemental analysis based on the measurement of characteristics radiation from radionuclides formed directly or indirectly by activation. The activation can be induced by bombarding the material with neutrons or charged particles or gamma rays. This is a well-accepted analytical technique for the determination of composition of complex materials. This technique is also sensitive at trace levels and is almost free from analytical interferences of matrix. It is used for multi-elemental determination in rocks, minerals, alloys, biological materials, geological samples, non-destructive analysis of materials and environmental samples such as water, air particulate matter, plants, soil, sediments and diets. This method is also used for production and measurements of radioisotopes in materials of known composition, for example, when radioactivation is used for nuclear reaction studies, for flux and beam intensity measurements for trace experiments and process quality control. In this article the parameters affecting the sensitivity of instrumental neutron activation analysis are briefly discussed. (author)

  3. Instrumental Neutron Activation Analysis and Multivariate Statistics for Pottery Provenance

    Science.gov (United States)

    Glascock, M. D.; Neff, H.; Vaughn, K. J.

    2004-06-01

    The application of instrumental neutron activation analysis and multivariate statistics to archaeological studies of ceramics and clays is described. A small pottery data set from the Nasca culture in southern Peru is presented for illustration.

  4. Instrumental Neutron Activation Analysis and Multivariate Statistics for Pottery Provenance

    International Nuclear Information System (INIS)

    Glascock, M. D.; Neff, H.; Vaughn, K. J.

    2004-01-01

    The application of instrumental neutron activation analysis and multivariate statistics to archaeological studies of ceramics and clays is described. A small pottery data set from the Nasca culture in southern Peru is presented for illustration.

  5. Instrumental Neutron Activation Analysis and Multivariate Statistics for Pottery Provenance

    Energy Technology Data Exchange (ETDEWEB)

    Glascock, M. D.; Neff, H. [University of Missouri, Research Reactor Center (United States); Vaughn, K. J. [Pacific Lutheran University, Department of Anthropology (United States)

    2004-06-15

    The application of instrumental neutron activation analysis and multivariate statistics to archaeological studies of ceramics and clays is described. A small pottery data set from the Nasca culture in southern Peru is presented for illustration.

  6. Direct Measurement of Initial Enrichment, Burn-up and Cooling Time of Spent Fuel Assembly with a Differential Die-Away Technique Based Instrument

    International Nuclear Information System (INIS)

    Henzl, Vladimir; Swinhoe, Martyn T.; Tobin, Stephen J.

    2012-01-01

    An outline of this presentation of what a Differential Die-Away (DDA) instrument can do are: (1) Principle of operation of DDA instrument; (2) Determination of initial enrichment (IE) (σ DDA response increases (die-away time is longer) with increasing fissile content; and (2) Spent fuel => DDA response decreases (die-away time is shorter) with higher burn-up (i.e. more neutron absorbers present).

  7. Instrumentation between science, state and industry

    CERN Document Server

    Shinn, Terry

    2001-01-01

    these. In this book, we appropriate their conception of research-technology, and ex­ tend it to many other phenomena which are less stable and less localized in time and space than the Zeeman/Cotton situation. In the following pages, we use the concept for instances where research activities are orientated primarily toward technologies which facilitate both the production of scientific knowledge and the production of other goods. In particular, we use the tenn for instances where instruments and meth­ ods· traverse numerous geographic and institutional boundaries; that is, fields dis­ tinctly different and distant from the instruments' and methods' initial focus. We suggest that instruments such as the ultra-centrifuge, and the trajectories of the men who devise such artefacts, diverge in an interesting way from other fonns of artefacts and careers in science, metrology and engineering with which students of science and technology are more familiar. The instrument systems developed by re­ search-technolo...

  8. Disability in instrumental activities of daily living among older adults: gender differences

    Directory of Open Access Journals (Sweden)

    Tiago da Silva Alexandre

    2014-06-01

    Full Text Available OBJECTIVE To analyze gender differences in the incidence and determinants of disability regarding instrumental activities of daily living among older adults. METHODS The data were extracted from the Saúde, Bem-Estar e Envelhecimento (SABE – Health, Wellbeing and Ageing study. In 2000, 1,034 older adults without difficulty in regarding instrumental activities of daily living were selected. The following characteristics were evaluated at the baseline: sociodemographic and behavioral variables, health status, falls, fractures, hospitalizations, depressive symptoms, cognition, strength, mobility, balance and perception of vision and hearing. Instrumental activities of daily living such as shopping and managing own money and medication, using transportation and using the telephone were reassessed in 2006, with incident cases of disability considered as the outcome. RESULTS The incidence density of disability in instrumental activities of daily living was 44.7/1,000 person/years for women and 25.2/1,000 person/years for men. The incidence rate ratio between women and men was 1.77 (95%CI 1.75;1.80. After controlling for socioeconomic status and clinical conditions, the incidence rate ratio was 1.81 (95%CI 1.77;1.84, demonstrating that women with chronic disease and greater social vulnerability have a greater incidence density of disability in instrumental activities of daily living. The following were determinants of the incidence of disability: age ≥ 80 and worse perception of hearing in both genders; stroke in men; and being aged 70 to 79 in women. Better cognitive performance was a protective factor in both genders and better balance was a protective factor in women. CONCLUSIONS The higher incidence density of disability in older women remained even after controlling for adverse social and clinical conditions. In addition to age, poorer cognitive performance and conditions that adversely affect communication disable both genders. Acute events

  9. Taking a positive spin: preserved initiative and performance of everyday activities across mild Alzheimer's, vascular and mixed dementia.

    Science.gov (United States)

    Giebel, Clarissa M; Burns, Alistair; Challis, David

    2017-09-01

    The literature commonly evaluates those daily activities which are impaired in dementia. However, in the mild stages, people with dementia (PwD) are still able to initiate and perform many of those tasks. With a lack of research exploring variations between different dementia diagnoses, this study sought to investigate those daily activities with modest impairments in the mild stages and how these compare between Alzheimer's disease (AD), vascular dementia (VaD) and mixed dementia. Staff from memory assessment services from nine National Health Service trusts across England identified and approached informal carers of people with mild dementia. Carers completed the newly revised Interview for Deteriorations in Daily Living Activities in Dementia 2 assessing the PwD's initiative and performance of instrumental activities of daily living (IADLs). Data were analysed using analysis of variance and Chi-square tests to compare the maintenance of IADL functioning across AD, VaD, and mixed dementia. A total of 160 carers returned the Interview for Deteriorations in Daily Living Activities in Dementia 2, of which 109, 21, and 30 cared for someone with AD, VaD, and mixed dementia, respectively. There were significant variations across subtypes, with AD showing better preserved initiative and performance than VaD for several IADLs. Overall, PwD showed greater preservation of performance than initiative, with tasks such as preparing a hot drink and dressing being best maintained. Findings can help classify dementia better into subtypes in order to receive bespoke support. It suggests that interventions should primarily address initiative to improve overall functioning. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  10. BIRA-IASB Mars activities and instrument capabilities

    Science.gov (United States)

    Drummond, R.; Vandaele, A.-C.; Gillotay, D.; Willame, Y.; Depiesse, C.; Patel, M.; Daerden, F.; Neefs, E.; Ristic, B.; Montmessin, F.

    2009-04-01

    The Belgian Institute of Space Aeronomy (BIRA-IASB) is involved in many areas of Mars exploration, and has been for a long time. Current activities include analysis of SPICAM data, 3D atmospheric modelling as well as instrument development and characterization. This paper will focus on two different instruments to study the Martian atmosphere. UVIS(Patel, 2006) is part of the Exomars payload, that will gather information on the UV levels on the ground, study climatology and sterilisation and also be able to detect organic material in sublimating permafrost. BIRA-IASB is carrying out the characterization and calibration of UVIS. SOIR is an infra-red spectrometer that uses solar occultation measurements to examine major and minor constituents of planetary atmospheres. SOIR is currently orbiting Venus on the VEX spacecraft and has already made several interesting discoveries including the first observations of a new band of a CO2 isotopologue. The data from SOIR-VEX has allowed us to study the instrumental characteristics and perform a sensitivity study(Mahieux, 2008). These properties have been used to simulate realistic SOIR measurements of Mars atmospheric spectra. This work is supported by extensive 3D chemistry modeling work, as described in a paper by Frank Daerden (PS2.9Atmospheres of terrestrial planets). M. R. Patel, et al.,(2006) The UV-VIS spectrometer for the ExoMars mission, in 36th COSPAR Scientific Assembly, Beijing, China. A. Mahieux, et al.,(2008), Appl. Opt. 47 (13), 2252-65.

  11. Intercomparison of active and passive instruments for radon and radon progeny in North America

    International Nuclear Information System (INIS)

    George, A.C.; Tu, Keng-Wu; Knutson, E.O.

    1995-02-01

    An intercomparison exercise for radon and radon progeny instruments and methods was held at the Environmental Measurements Laboratory (EML) from April 22--May 2, 1994. The exercise was conducted in the new EML radon test and calibration facility in which conditions of exposure are very well controlled. The detection systems of the intercompared instruments consisted of. (1) pulse ionization chambers, (2) electret ionization chambers, (3) scintillation detectors, (4) alpha particle spectrometers with silicon diodes, surface barrier or diffused junction detectors, (5) registration of nuclear tracks in solid-state materials, and (6) activated carbon collectors counted by gamma-ray spectrometry or by alpha- and beta-liquid scintillation counting. 23 private firms, government laboratories and universities participated with a 165 passive integrating devices consisting of: Activated carbon collectors, nuclear alpha track detectors and electret ionization chambers, and 11 active and passive continuous radon monitors. Five portable integrating and continuous instruments were intercompared for radon progeny. Forty grab samples for radon progeny were taken by five groups that participated in person to test and evaluate their primary instruments and methods that measure individual radon progeny and the potential alpha energy concentration (PAEC) in indoor air. Results indicate that more than 80% of the measurements for radon performed with a variety of instruments, are within ±10% of actual value. The majority of the instruments that measure individual radon progeny and the PAEC gave results that are in good agreement with the EML reference value. Radon progeny measurements made with continuous and integrating instruments are satisfactory with room for improvement

  12. Intercomparison and intercalibration of passive/active radon and active radon progeny instruments and methods in North America

    International Nuclear Information System (INIS)

    George, A.C.; Tu, Keng W.

    1993-06-01

    An intercomparison and intercalibration exercise for radon and radon progeny measurements made with active and passive instruments was held at EML from October 22--30,1992. Twenty-five participants submitted 96 passive integrating devices, eight active devices for radon, and seven integrating devices for potential alpha energy concentration (PAEC). In addition, 40 grab samples for radon progeny analysis were taken by five groups that participated in person during the intercomparison. The results reported to EML indicate that the majority of the participants (70%) obtained mean results within 10% of the EML reference value. Although the instruments used in this exercise are based on different principles of collection and detection, they all appear reliable. However, in some instances there seemed to be some minor problems with quality control and calibration bias. Also, the large counting errors for the PAEC experienced by some of the participants can be minimized by using higher sampling air flow rates without sacrificing instrument portability

  13. Economic instruments for population diet and physical activity behaviour change: a systematic scoping review.

    Directory of Open Access Journals (Sweden)

    Ian Shemilt

    Full Text Available Unhealthy diet and low levels of physical activity are common behavioural factors in the aetiology of many non-communicable diseases. Recent years have witnessed an upsurge of policy and research interest in the use of taxes and other economic instruments to improve population health.To assemble, configure and analyse empirical research studies available to inform the public health case for using economic instruments to promote dietary and physical activity behaviour change.We conducted a systematic scoping review of evidence for the effects of specific interventions to change, or general exposure to variations in, prices or income on dietary and physical activity behaviours and corollary outcomes. Systematic electronic searches and parallel snowball searches retrieved >1 million study records. Text mining technologies were used to prioritise title-abstract records for screening. Eligible studies were selected, classified and analysed in terms of key characteristics and principal findings, using a narrative, configuring synthesis focused on implications for policy and further research.We identified 880 eligible studies, including 192 intervention studies and 768 studies that incorporated evidence for prices or income as correlates or determinants of target outcomes. Current evidence for the effects of economic instruments and exposures on diet and physical activity is limited in quality and equivocal in terms of its policy implications. Direct evidence for the effects of economic instruments is heavily skewed towards impacts on diet, with a relative lack of evidence for impacts on physical activity.The evidence-based case for using economic instruments to promote dietary and physical activity behaviour change may be less compelling than some proponents have claimed. Future research should include measurement of people's actual behavioural responses using study designs capable of generating reliable causal inferences regarding intervention

  14. Determination of toxic elements in tobacco by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Yaprak, G.; Cam, N.F.

    1998-01-01

    The concentration of toxic elements in the tobacco of six different brands of domestic and two brands of imported cigarettes heavily smoked in Turkey were determined using instrumental neutron activation analysis (INAA)

  15. Leasing instruments of high-rise construction financing

    Science.gov (United States)

    Aleksandrova, Olga; Ivleva, Elena; Sukhacheva, Viktoria; Rumyantseva, Anna

    2018-03-01

    The leasing sector of the business economics is expanding. Leasing instruments for high-rise construction financing allow to determine the best business behaviour in the leasing economy sector, not only in the sphere of transactions with equipment and vehicles. Investments in high-rise construction have a multiplicative effect. It initiates an active search and leasing instruments use in the economic behaviour of construction organizations. The study of the high-rise construction sector in the structure of the leasing market participants significantly expands the leasing system framework. The scheme of internal and external leasing process factors influence on the result formation in the leasing sector of economy is offered.

  16. Brain activation during dichotic presentations of consonant-vowel and musical instrument stimuli: a 15O-PET study.

    Science.gov (United States)

    Hugdahl, K; Brønnick, K; Kyllingsbaek, S; Law, I; Gade, A; Paulson, O B

    1999-04-01

    Dichotic listening means that two different stimuli are presented at the same time, one in each ear. This technique is frequently used in experimental and clinical studies as a measure of hemispheric specialization. The primary aim of the present study was to record regional changes in the distribution of cerebral blood flow (CBF) with the 15O-PET technique to dichotically presented consonant-vowel (CV) and musical instrument stimuli, in order to test the basic assumption of differential hemispheric involvement when stimuli presented to one ear dominate over stimuli presented in the other ear. All stimuli were 380 ms in duration with a 1000 ms interstimulus interval, and were presented in blocks of either CV-syllable or musical instrument pairs. Twelve normal healthy subjects had to press a button whenever they detected a CV-syllable or a musical instrument target in a stream of CV- and musical instrument distractor stimuli. The targets appeared equally often in the right and left ear channel. The CV-syllable and musical instrument targets activated bilateral areas in the superior temporal gyri. However, there were significant interactions with regard to asymmetry of the magnitude of peak activation in the significant activation clusters. The CV-syllables resulted in greater neural activation in the left temporal lobe while the musical instruments resulted in greater neural activation in the right temporal lobe. Within-subjects correlations between magnitude of dichotic listening and CBF asymmetry were, however, non-significant. The changes in neural activation were closely mimicked by the performance data which showed a right ear superiority in response accuracy for the CV-syllables, and a left ear superiority for the musical instruments. In addition to the temporal lobe activations, there were activation tendencies in the left inferior frontal lobe, right dorsolateral prefrontal cortex, left occipital lobe, and cerebellum.

  17. 40+ Years of Instrumentation for the La Silla Paranal Observatory

    Science.gov (United States)

    D'Odorico, S.

    2018-03-01

    As ESO Period 100 comes to a close, I look back at the development of ESO's instrumentation programme over more than 40 years. Instrumentation and detector activities were initially started by a small group of designers, engineers, technicians and astronomers while ESO was still at CERN in Geneva in the late 1970s. They have since led to the development of a successful suite of optical and infrared instruments for the La Silla Paranal Observatory, as testified by the continuous growth in the number of proposals for observing time and in the publications based on data from ESO telescopes. The instrumentation programme evolved significantly with the VLT and most instruments were developed by national institutes in close cooperation with ESO. This policy was a cornerstone of the VLT programme from the beginning and a key to its success.

  18. Development of instrument for assessing students’ critical and creative thinking ability

    Science.gov (United States)

    Herpiana, R.; Rosidin, U.

    2018-01-01

    The purpose of this study was to develop instruments to measure critical thinking ability and creative students in the topics of physics simple harmonic motion. The research method used was research development with application of procedures including research and data collection, planning, and initial product development. The participants of the study were thirty-four tenth grade students and five physics teachers of physics who were selected randomly from schools in the province of Lampung. The data collected by using test and analyzed in quantitative descriptive. Initial data showed that students’ critical and creative thinking ability were still low and instruments to assess students’ critical thinking skills and creative students was not yet available. Most of assessment conducted focused on memorization. Thus, the researchers developed a draft of instrument in the form of the test description based on criteria that encouraged students’ activity in understanding the concepts, strategies and decision/solution in dealing with problems. The development of the instrument was conducted considering real-world phenomena in the form of pictures and stories, description of the situation, and verbal presentation.

  19. Instrumental neutron activation analysis of wheat bunt spores

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y G; Schmitt, R A [Oregon State Univ., Corvallis (USA). Dept. of Chemistry; Oregon State Univ., Corvallis (USA). Radiation Center); Trione, E J [Oregon State Univ., Corvallis (USA). Dept. of Botany; Laul, J C [Battelle Pacific Northwest Labs., Richland, WA (USA)

    1982-01-01

    The concentrations of seventeen elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Cr, Mn, Fe, Co, Zn, Br, Rb, La, Sm) in two species of fungus which cause wheat bunt disease, Tilletia caries (DC.) Tul. and Tilletia controversa Kuehn, were determined by instrumental neutron activation analysis. A standard sequential INAA procedure was used. Differences in the K and Cl concentrations between these two species of spores are large and therefore can be used as a criterion of distinguishing between the two species of fungus.

  20. Effect of the size of the apical enlargement with rotary instruments, single-cone filling, post space preparation with drills, fiber post removal, and root canal filling removal on apical crack initiation and propagation.

    Science.gov (United States)

    Çapar, İsmail Davut; Uysal, Banu; Ok, Evren; Arslan, Hakan

    2015-02-01

    The purpose of this study was to investigate the incidence of apical crack initiation and propagation in root dentin after several endodontic procedures. Sixty intact mandibular premolars were sectioned perpendicular to the long axis at 1 mm from the apex, and the apical surface was polished. Thirty teeth were left unprepared and served as a control, and the remaining 30 teeth were instrumented with ProTaper Universal instruments (Dentsply Maillefer, Ballaigues, Switzerland) up to size F5. The root canals were filled with the single-cone technique. Gutta-percha was removed with drills of the Rebilda post system (VOCO, Cuxhaven, Germany). Glass fiber-reinforced composite fiber posts were cemented using a dual-cure resin cement. The fiber posts were removed with a drill of the post system. Retreatment was completed after the removal of the gutta-percha. Crack initiation and propagation in the apical surfaces of the samples were examined with a stereomicroscope after each procedure. The absence/presence of cracks was recorded. Logistic regression was performed to analyze statistically the incidence of crack initiation and propagation with each procedure. The initiation of the first crack and crack propagation was associated with F2 and F4 instruments, respectively. The logistic regression analysis revealed that instrumentation and F2 instrument significantly affected apical crack initiation (P .05). Rotary nickel-titanium instrumentation had a significant effect on apical crack initiation, and post space preparation with drills had a significant impact on crack propagation. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  1. Legal Instruments of Regulation of Development of Banking Activity in Ukraine

    Directory of Open Access Journals (Sweden)

    Senyshch Pavlo M.

    2014-03-01

    Full Text Available The article considers main approaches to identification of essence of legal instruments of regulation of development of the banking activity, identifies the mechanism of legal regulation of the banking activity and its elements and justifies the system and form of legal regulation of the banking activity in Ukraine. It describes subjects of legal regulation of the banking activity at the international level, which are the Basel Committee on Banking Supervision, European Central Bank, IMF, International Financial Reporting Standards Foundation and others. The article considers specific features of the regulatory requirements of Basel II and Basel III and specific features of their introduction into the banking activity. It describes anti-cyclic measures offered by the Basel Committee, which should facilitate formation of such conditions, under which the banking sector could have a lower level of leverage and stability with respect to influence of system risks. Significant attention is paid to international instruments of regulation of the banking activity, which include the following legal acts: Uniform Rules for Collections, Uniform Customs and Practice for Documentary Credits, and Unified Rules for Loan Guarantees. The article shows that the share of subordinate legal acts is significant in the Ukrainian system of banking regulatory and legal acts since the state cannot operatively react to the changing processes in banking at the legislative level and, that is why, basic provisions on carrying out banking activity should be fixed in law.

  2. Ocean Bottom Seismograph Performance during the Cascadia Initiative

    Science.gov (United States)

    Aderhold, K.; Evers, B.

    2015-12-01

    The Ocean Bottom Seismograph Instrument Pool (OBSIP) provides instrumentation and operations support for the Cascadia Initiative community experiment. This experiment investigates geophysical processes across the Cascadia subduction zone through a combination of onshore and offshore seismic data. The recovery of Year 4 instruments in September 2015 marks the conclusion of a multi-year experiment that utilized 60 ocean-bottom seismographs (OBSs) specifically designed for the subduction zone boundary, including shallow/deep water deployments and active fisheries. The new instruments feature trawl-resistant enclosures designed by Lamont-Doherty Earth Observatory (LDEO) and Scripps Institution of Oceanography (SIO) for shallow deployment [water depth ≤ 500 m], as well as new deep-water instruments designed by Woods Hole Oceanographic Institute (WHOI). Existing OBSIP instruments were also deployed along the Blanco Transform Fault and on the Gorda Plate through complementary experiments. Stations include differential pressure gauges (DPG) and absolute pressure gauges (APG). All data collected from the Cascadia, Blanco, and Gorda deployments will be freely available through the Incorporated Research Institutions for Seismology (IRIS) Data Management Center (DMC). The Cascadia Initiative is the largest amphibious seismic experiment undertaken to date and demonstrates an effective structure for community experiments through collaborative efforts from the Cascadia Initiative Expedition Team (CIET), OBSIP (institutional instrument contributors [LDEO, SIO, WHOI] and Management Office [IRIS]), and the IRIS DMC. The successes and lessons from Cascadia are a vital resource for the development of a Subduction Zone Observatory (SZO). To guide future efforts, we investigate the quality of the Cascadia OBS data using basic metrics such as instrument recovery and more advanced metrics such as noise characteristics through power spectral density analysis. We also use this broad and

  3. Identification Of Financial Instruments – Important Step in Building Portfolios

    Directory of Open Access Journals (Sweden)

    Mădălina-Gabriela Anghel

    2013-10-01

    Full Text Available Construction of any portfolio is initially identifying financial instruments to be traded, and the timing for entering the capital market (ie the optimal timing of trading . This is the stage in which the market analysis is made in order to collect the necessary information in making investment decision. In this regard it is recommended that investment activity should be based on a thorough evaluation of both the individual performance of the instruments to be purchased and the overall development of the capital market on which the investment is to be made.

  4. Instruments to stimulate activation of older persons on labor market

    Directory of Open Access Journals (Sweden)

    Klaudia Lucius

    2015-03-01

    Full Text Available The topic of ageing society and its influence on shaping economy is one of the priorities in political discussions nowadays.  The trend of increasing population of 50+ years old people is visible in most of the highly developed European countries. This situation induces countries with changing demographical structure to implement solutions that will extend the job activity of people in the immobile age. The best example is Germany, where the introduction of structural reforms in the labor market employment in the 55+ group increased in 10 years by 20%.  Effective management of the community of older people is necessary to keep the balance in economy. Many examples of good case practices from chosen European countries point an important role of education in this process. Education is a tool that aims to support older people in functioning on the job market and increase employers’ awareness of changes and solutions that need to be implemented in their companies. Customized forms of employment are another instrument of increasing job activity of older people. They let employers adjust the time, place of work, job description and form of payment according to the employer’s and employee’s preferences. Though, the most significant instrument is reduction of unemployment benefits for people who are qualified to take job activity. In this case one of the solutions is applying temporary benefits that stimulate active job hunting. The mentioned activities, to ensure their efficiency, should be supported by adequate law regulations.

  5. Applied research of environmental monitoring using instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Young Sam; Moon, Jong Hwa; Chung, Young Ju

    1997-08-01

    This technical report is written as a guide book for applied research of environmental monitoring using Instrumental Neutron Activation Analysis. The contents are as followings; sampling and sample preparation as a airborne particulate matter, analytical methodologies, data evaluation and interpretation, basic statistical methods of data analysis applied in environmental pollution studies. (author). 23 refs., 7 tabs., 9 figs.

  6. Cognitive Activities and Instrumental Activity of Daily Living in Older Adults with Mild Cognitive Impairment

    Directory of Open Access Journals (Sweden)

    Takehiko Doi

    2013-10-01

    Full Text Available Aims: This study aimed to identify differences in the implementation of cognitive activities and instrumental activities of daily living (IADLs between healthy individuals and subjects with mild cognitive impairment (MCI. Methods: The study included 2,498 cognitively healthy subjects (mean age, 71.2 ± 5.1 years and 809 MCI subjects (mean age, 71.8 ± 5.4 years. The subjects were interviewed regarding their participation in cognitive activities and the implementation of IADLs. Results: We found a significant association between participation in any cognitive activities (p Conclusions: Our study revealed that greater participation in cognitive activity was associated with lower odds of MCI. Participation in cognitive activities may reflect differences between healthy and MCI subjects. To clarify the causal relationship between cognitive activities and MCI, further studies are required.

  7. A qualitative review of instrumental activities of daily living in dementia: what's cooking?

    NARCIS (Netherlands)

    Sikkes, S.A.M.; de Rotrou, J.

    2014-01-01

    The measurement of instrumental activities of daily living (IADL) is common in clinical practice and research into dementia. IADL are cognitively complex daily activities, such as cooking and doing finances. Their measurement is required for the diagnostic process of dementia, and also useful for

  8. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  9. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  10. Trace elements in Turkish tobacco determined by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Guelovali, M.C.; Guenduez, G.

    1983-01-01

    The concentration of 20 trace elements in nine brands of Turkish cigarette tobacco and in a brand of pipe tobacco ash has been determined by instrumental neutron activation analysis. The percent transference of elements into smoke has been estimated from the amounts remaining in the ash. (author)

  11. Strengthening the Idea of “By Citizens, for Citizens” in the Context of the European Citizens' Initiative - Brief Analysis of Initiatives

    Directory of Open Access Journals (Sweden)

    Oana - Măriuca Petrescu

    2014-06-01

    Full Text Available Regulation (EU No. 211 of 16 February 2011 on the European Citizens' Initiative (ECI, as one of the major innovations of the Treaty of Lisbon, represents the first supranational instrument of direct democracy that took effect on April 1, 2012, creating the direct legal link between the European Union citizens and the European institutions. Within the present paper we will give a general overview of the European Citizens’ Initiative instrument, trying also to analyse briefly certain citizens’ initiatives that have been already registered on the European Commission’s website where the online collection of a million signatures is still running, bearing in mind the important role of the citizens as “co-authors” of the law within the European decision-making process. From our point of view this participation will increase the responsibility of the citizens to be more active and to use their new right in the best conditions and without any obstacles.

  12. Avoidance-based human Pavlovian-to-instrumental transfer

    Science.gov (United States)

    Lewis, Andrea H.; Niznikiewicz, Michael A.; Delamater, Andrew R.; Delgado, Mauricio R.

    2013-01-01

    The Pavlovian-to-instrumental transfer (PIT) paradigm probes the influence of Pavlovian cues over instrumentally learned behavior. The paradigm has been used extensively to probe basic cognitive and motivational processes in studies of animal learning but, more recently, PIT and its underlying neural basis have been extended to investigations in humans. These initial neuroimaging studies of PIT have focused on the influence of appetitively conditioned stimuli on instrumental responses maintained by positive reinforcement, and highlight the involvement of the striatum. In the current study, we sought to understand the neural correlates of PIT in an aversive Pavlovian learning situation when instrumental responding was maintained through negative reinforcement. Participants exhibited specific PIT, wherein selective increases in instrumental responding to conditioned stimuli occurred when the stimulus signaled a specific aversive outcome whose omission negatively reinforced the instrumental response. Additionally, a general PIT effect was observed such that when a stimulus was associated with a different aversive outcome than was used to negatively reinforce instrumental behavior, the presence of that stimulus caused a non-selective increase in overall instrumental responding. Both specific and general PIT behavioral effects correlated with increased activation in corticostriatal circuitry, particularly in the striatum, a region involved in cognitive and motivational processes. These results suggest that avoidance-based PIT utilizes a similar neural mechanism to that seen with PIT in an appetitive context, which has implications for understanding mechanisms of drug-seeking behavior during addiction and relapse. PMID:24118624

  13. Nuclear power plant control and instrumentation activities in Argentina during 1989-1991

    International Nuclear Information System (INIS)

    Lorenzetti, J.R.

    1992-01-01

    A brief resume of the activities in the different areas of control and instrumentation is included. As there was a delay in the construction of the new power plant most of the effort were dedicated to the plants that they are in operation. It has been added instrumentation to have better information in the control room and to check new variables of the plant according with the experience learned from the operation. It was dedicated special strength in the areas of training simulators and in service inspection. (author)

  14. Listening to Learn: The Status of Listening Activities in Secondary Instrumental Ensemble Classes

    Science.gov (United States)

    Prichard, Stephanie

    2013-01-01

    The purpose of this study was to determine the status of listening activities as part of middle and high school instrumental music instruction. Research questions addressed teachers' beliefs in the importance of listening, outcomes associated with listening, type and frequency of listening activities, presence of guided listening, and challenges…

  15. The Integration of Corporate Social Responsibility (CSR) Initiatives into Business Activities

    DEFF Research Database (Denmark)

    Knudsen, Jette Steen

    While proponents of Corporate Social Responsibility (CSR) have suggested that CSR initiatives should be integrated into mainstream business activities as ‘strategic CSR’ or ‘shared value’, research is lacking that explores how CSR initiatives are integrated in companies. This article compares CSR...... initiatives to human resource management (HRM) initiatives, which have a longer tradition of being integrated into company strategy. The focus is on gender diversity and CSR initiatives in a US multinational corporation (MNC). The MNC sees gender diversity as an integral part of business activities...

  16. Trace element concentrations in human bone using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    El-Amri, F.A.; El-Kabroun, M.A.R.

    1997-01-01

    Instrumental neutron activation analysis has been applied to analyze 23 bone samples obtained from Libyan patient aged (3-80) years for the study of the concentration levels of trace elements Ba, Br, Ca, Fe, Sr and Zn and their concentration patterns regarding to the age and sex of the patients. (author)

  17. Current studies of biological materials using instrumental and radiochemical neutron activation analysis

    International Nuclear Information System (INIS)

    Fardy, J.J.; McOrist, G.D.; Farrar, Y.J.

    1985-01-01

    Instrumental neutron activation analysis still remains the preferred option when analysing the trace element distribution in a wide rage of materials by neutron activation analysis. However, when lower limits of detection are required or major interferences reduce the effectiveness of this technique, radiochemical neutron activation analysis is applied. This paper examines the current use of both methods and the development of rapid radiochemical techniques for analysis of the biological materials, hair, cow's milk, human's milk, milk powder, blood and blood serum

  18. An assessment of self-reported physical activity instruments in young people for population surveillance: Project ALPHA

    Directory of Open Access Journals (Sweden)

    Pearson Natalie

    2011-01-01

    Full Text Available Abstract Background The assessment of physical activity is an essential part of understanding patterns and influences of behaviour, designing interventions, and undertaking population surveillance and monitoring, but it is particularly problematic when using self-report instruments with young people. This study reviewed available self-report physical activity instruments developed for use with children and adolescents to assess their suitability and feasibility for use in population surveillance systems, particularly in Europe. Methods Systematic searches and review, supplemented by expert panel assessment. Results Papers (n = 437 were assessed as potentially relevant; 89 physical activity measures were identified with 20 activity-based measures receiving detailed assessment. Three received support from the majority of the expert group: Physical Activity Questionnaire for Children/Adolescents (PAQ-C/PAQ-A, Youth Risk Behaviour Surveillance Survey (YRBS, and the Teen Health Survey. Conclusions Population surveillance of youth physical activity is strongly recommended and those involved in developing and undertaking this task should consider the three identified shortlisted instruments and evaluate their appropriateness for application within their national context. Further development and testing of measures suitable for population surveillance with young people is required.

  19. Online communication predicts Belgian adolescents' initiation of romantic and sexual activity.

    Science.gov (United States)

    Vandenbosch, Laura; Beyens, Ine; Vangeel, Laurens; Eggermont, Steven

    2016-04-01

    Online communication is associated with offline romantic and sexual activity among college students. Yet, it is unknown whether online communication is associated with the initiation of romantic and sexual activity among adolescents. This two-wave panel study investigated whether chatting, visiting dating websites, and visiting erotic contact websites predicted adolescents' initiation of romantic and sexual activity. We analyzed two-wave panel data from 1163 Belgian adolescents who participated in the MORES Study. We investigated the longitudinal impact of online communication on the initiation of romantic relationships and sexual intercourse using logistic regression analyses. The odds ratios of initiating a romantic relationship among romantically inexperienced adolescents who frequently used chat rooms, dating websites, or erotic contact websites were two to three times larger than those of non-users. Among sexually inexperienced adolescents who frequently used chat rooms, dating websites, or erotic contact websites, the odds ratios of initiating sexual intercourse were two to five times larger than that among non-users, even after a number of other relevant factors were introduced. This is the first study to demonstrate that online communication predicts the initiation of offline sexual and romantic activity as early as adolescence. Practitioners and parents need to consider the role of online communication in adolescents' developing sexuality. • Adolescents increasingly communicate online with peers. • Online communication predicts romantic and sexual activity among college students. What is New: • Online communication predicts adolescents' offline romantic activity over time. • Online communication predicts adolescents' offline sexual activity over time.

  20. Development of an instrumented and active servocontrolled robot gripper

    International Nuclear Information System (INIS)

    Debnath, S.K.; Dutta, A.K.; Deb, S.R.

    1990-01-01

    The design and construction of an instrumented and active robotic gripper is presented in this paper. The gripping device is a four-bar-linkage parallel jaw type end effector and the fingers are actuated by DC servo motor and gear drive. To make the gripper active, it is equipped with several sensors viz. straingauge type force sensor, magnetic proximity sensor, infrared sensor and vision sensor. A potentiometric position sensor is used to give position feed back of the fingers to the gripper controller. All sensory data are received by a Z-80 microprocessor and a software is developed to process data to transmit corresponding signals to the servocontroller designed for the gripper activation. The gripper can be used for automated grasping of randomly scattered object that remains in the field of view of the camera mounted on the gripper. (author). 3 refs., 2 figs

  1. Use of Adult Patient Focus Groups to Develop the Initial Item Bank for a Cochlear Implant Quality-of-Life Instrument.

    Science.gov (United States)

    McRackan, Theodore R; Velozo, Craig A; Holcomb, Meredith A; Camposeo, Elizabeth L; Hatch, Jonathan L; Meyer, Ted A; Lambert, Paul R; Melvin, Cathy L; Dubno, Judy R

    2017-10-01

    No instrument exists to assess quality of life (QOL) in adult cochlear implant (CI) users that has been developed and validated using accepted scientific standards. To develop a CI-specific QOL instrument for adults in accordance with the Patient Reported Outcomes Measurement Information System (PROMIS) guidelines. As required in the PROMIS guidelines, patient focus groups participated in creation of the initial item bank. Twenty-three adult CI users were divided into 1 of 3 focus groups stratified by word recognition ability. Three moderator-led focus groups were conducted based on grounded theory on December 3, 2016. Two reviewers independently analyzed focus group recordings and transcripts, with a third reviewer available to resolve discrepancies. All data were reviewed and reported according to the Consolidated Criteria for Reporting Qualitative Research. The setting was a tertiary referral center. Coded focus group data. The 23 focus group participants (10 [43%] female; mean [range] age, 68.1 [46.2-84.2] years) represented a wide range of income levels, education levels, listening modalities, CI device manufacturers, duration of CI use, and age at implantation. Data saturation was determined to be reached before the conclusion of each of the focus groups. After analysis of the transcripts, the central themes identified were communication, emotion, environmental sounds, independence and work function, listening effort, social isolation and ability to socialize, and sound clarity. Cognitive interviews were carried out on 20 adult CI patients who did not participate in the focus groups to ensure item clarity. Based on these results, the initial QOL item bank and prototype were developed. Patient focus groups drawn from the target population are the preferred method of identifying content areas and domains for developing the item bank for a CI-specific QOL instrument. Compared with previously used methods, the use of patient-centered item development for a CI

  2. A study on cigarette tobacco by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Md Soot Haji Ahmad; Tey Nsan Yen

    1987-01-01

    The concentration of 25 elements in cigarette tobacco of popular brands locally marketed were determined using instrumental neutron activation analysis. These elements are: Al, Ba, Br, Ca, Ce, Cl, Co, Cr, Cs, Eu, Fe, Hf, Hg, K, La, Mg, Mn, Na, Rb, Sb, Sc, Se, Sr, Th, and Zn. Comparison of the element contents to the reported cigarette tobacco of Egypt, Iran and Turkey was also done. (author)

  3. Remote sensing optical instrumentation for enhanced space weather monitoring from the L1 and L5 Lagrange points

    Science.gov (United States)

    Kraft, S.; Puschmann, K. G.; Luntama, J. P.

    2017-09-01

    As part of the Space Situational Awareness Programme (SSA), ESA has initiated the assessment of two missions currently foreseen to be implemented to enable enhanced space weather monitoring. These missions utilize the positioning of satellites at the Lagrangian L1 and L5 points. These Phase 0 or Pre-Phase A mission studies are about to be completed and will thereby have soon passed the Mission Definition Review. Phase A studies are planned to start in 2017. The space weather monitoring system currently considers four remote sensing optical instruments and several in-situ instruments to analyse the Sun and the solar wind conditions, in order to provide early warnings of increased solar activity and to identify and mitigate potential threats to society and ground, airborne and space based infrastructure. The suggested optical instruments take heritage from ESA and NASA science missions like SOHO, STEREO and Solar Orbiter, but the instruments are foreseen to be optimized for operational space weather monitoring purposes with high reliability and robustness demands. The instruments are required to provide high quality measurements particularly during severe space weather events. The program intends to utilize the results of the on-going ESA instrument prototyping and technology development activities, and to initiate pre-developments of the operational space weather instruments to ensure the required maturity before the mission implementation.

  4. Design of a novel instrument for active neutron interrogation of artillery shells.

    Science.gov (United States)

    Bélanger-Champagne, Camille; Vainionpää, Hannes; Peura, Pauli; Toivonen, Harri; Eerola, Paula; Dendooven, Peter

    2017-01-01

    The most common explosives can be uniquely identified by measuring the elemental H/N ratio with a precision better than 10%. Monte Carlo simulations were used to design two variants of a new prompt gamma neutron activation instrument that can achieve this precision. The instrument features an intense pulsed neutron generator with precise timing. Measuring the hydrogen peak from the target explosive is especially challenging because the instrument itself contains hydrogen, which is needed for neutron moderation and shielding. By iterative design optimization, the fraction of the hydrogen peak counts coming from the explosive under interrogation increased from [Formula: see text]% to [Formula: see text]% (statistical only) for the benchmark design. In the optimized design variants, the hydrogen signal from a high-explosive shell can be measured to a statistics-only precision better than 1% in less than 30 minutes for an average neutron production yield of 109 n/s.

  5. Sox2 is translationally activated by eukaryotic initiation factor 4E in human glioma-initiating cells

    Energy Technology Data Exchange (ETDEWEB)

    Ge, Yuqing; Zhou, Fengbiao; Chen, Hong; Cui, Chunhong; Liu, Dan [Key Laboratory of Glycoconjuates Research, Ministry of Public Health and Gene Research Center, Shanghai Medical College of Fudan University, Shanghai 200032 (China); Li, Qiuping [Zhongshan Hospital of Fudan University, Shanghai 200032 (China); Yang, Zhiyuan; Wu, Guoqiang [Key Laboratory of Glycoconjuates Research, Ministry of Public Health and Gene Research Center, Shanghai Medical College of Fudan University, Shanghai 200032 (China); Sun, Shuhui [Key Laboratory of Medical Molecular Virology, Ministry of Education and Health, Shanghai Medical College of Fudan University, Shanghai 200032 (China); Gu, Jianxin [Key Laboratory of Glycoconjuates Research, Ministry of Public Health and Gene Research Center, Shanghai Medical College of Fudan University, Shanghai 200032 (China); Institutes of Biomedical Sciences of Fudan University, Shanghai 200032 (China); Wei, Yuanyan, E-mail: yywei@fudan.edu.cn [Key Laboratory of Glycoconjuates Research, Ministry of Public Health and Gene Research Center, Shanghai Medical College of Fudan University, Shanghai 200032 (China); Jiang, Jianhai, E-mail: jianhaijiang@fudan.edu.cn [Key Laboratory of Glycoconjuates Research, Ministry of Public Health and Gene Research Center, Shanghai Medical College of Fudan University, Shanghai 200032 (China)

    2010-07-09

    Sox2, a master transcription factor, contributes to the generation of induced pluripotent stem cells and plays significant roles in sustaining the self-renewal of neural stem cells and glioma-initiating cells. Understanding the functional differences of Sox2 between glioma-initiating cells and normal neural stem cells would contribute to therapeutic approach for treatment of brain tumors. Here, we first demonstrated that Sox2 could contribute to the self-renewal and proliferation of glioma-initiating cells. The following experiments showed that Sox2 was activated at translational level in a subset of human glioma-initiating cells compared with the normal neural stem cells. Further investigation revealed there was a positive correlation between Sox2 and eukaryotic initiation factor 4E (eIF4E) in glioma tissues. Down-regulation of eIF4E decreased Sox2 protein level without altering its mRNA level in glioma-initiating cells, indicating that Sox2 was activated by eIF4E at translational level. Furthermore, eIF4E was presumed to regulate the expression of Sox2 by its 5' untranslated region (5' UTR) sequence. Our results suggest that the eIF4E-Sox2 axis is a novel mechanism of unregulated self-renewal of glioma-initiating cells, providing a potential therapeutic target for glioma.

  6. Sox2 is translationally activated by eukaryotic initiation factor 4E in human glioma-initiating cells

    International Nuclear Information System (INIS)

    Ge, Yuqing; Zhou, Fengbiao; Chen, Hong; Cui, Chunhong; Liu, Dan; Li, Qiuping; Yang, Zhiyuan; Wu, Guoqiang; Sun, Shuhui; Gu, Jianxin; Wei, Yuanyan; Jiang, Jianhai

    2010-01-01

    Sox2, a master transcription factor, contributes to the generation of induced pluripotent stem cells and plays significant roles in sustaining the self-renewal of neural stem cells and glioma-initiating cells. Understanding the functional differences of Sox2 between glioma-initiating cells and normal neural stem cells would contribute to therapeutic approach for treatment of brain tumors. Here, we first demonstrated that Sox2 could contribute to the self-renewal and proliferation of glioma-initiating cells. The following experiments showed that Sox2 was activated at translational level in a subset of human glioma-initiating cells compared with the normal neural stem cells. Further investigation revealed there was a positive correlation between Sox2 and eukaryotic initiation factor 4E (eIF4E) in glioma tissues. Down-regulation of eIF4E decreased Sox2 protein level without altering its mRNA level in glioma-initiating cells, indicating that Sox2 was activated by eIF4E at translational level. Furthermore, eIF4E was presumed to regulate the expression of Sox2 by its 5' untranslated region (5' UTR) sequence. Our results suggest that the eIF4E-Sox2 axis is a novel mechanism of unregulated self-renewal of glioma-initiating cells, providing a potential therapeutic target for glioma.

  7. Physical activity and life satisfaction in adolescence: The mediating role of initiative

    OpenAIRE

    Skagseth, Inga Fjelltveit

    2008-01-01

    Background: The ability to take initiative is considered an important developmental task in adolescence. Organised leisure time activities have been suggested as especially conducive contexts for initiative development. Therefore, the aim of this thesis was to investigate the relationship between leisure time physical activity, initiative, and life satisfaction in adolescence. The self-determination theory was used to identify factors that facilitate intrinsic motivation, initiative, and life...

  8. Developing a theory-based instrument to assess the impact of continuing professional development activities on clinical practice: a study protocol

    Directory of Open Access Journals (Sweden)

    Rousseau Michel

    2011-03-01

    Full Text Available Abstract Background Continuing professional development (CPD is one of the principal means by which health professionals (i.e. primary care physicians and specialists maintain, improve, and broaden the knowledge and skills required for optimal patient care and safety. However, the lack of a widely accepted instrument to assess the impact of CPD activities on clinical practice thwarts researchers' comparisons of the effectiveness of CPD activities. Using an integrated model for the study of healthcare professionals' behaviour, our objective is to develop a theory-based, valid, reliable global instrument to assess the impact of accredited CPD activities on clinical practice. Methods Phase 1: We will analyze the instruments identified in a systematic review of factors influencing health professionals' behaviours using criteria that reflect the literature on measurement development and CPD decision makers' priorities. The outcome of this phase will be an inventory of instruments based on social cognitive theories. Phase 2: Working from this inventory, the most relevant instruments and their related items for assessing the concepts listed in the integrated model will be selected. Through an e-Delphi process, we will verify whether these instruments are acceptable, what aspects need revision, and whether important items are missing and should be added. The outcome of this phase will be a new global instrument integrating the most relevant tools to fit our integrated model of healthcare professionals' behaviour. Phase 3: Two data collections are planned: (1 a test-retest of the new instrument, including item analysis, to assess its reliability and (2 a study using the instrument before and after CPD activities with a randomly selected control group to explore the instrument's mere-measurement effect. Phase 4: We will conduct individual interviews and focus groups with key stakeholders to identify anticipated barriers and enablers for implementing the

  9. Analysis for trace mercury concentration. I. Critical evaluation of current procedures. II. A proposed method for determination by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Litman, R.

    1975-01-01

    Current methods of sample pretreatments, digestion, lyophilization and extraction, have been found to lead to considerable loss of mercury, at an initial mercury concentration of 1 μg/g, and less. Storage of solutions of mercury at concentrations of less than 1 μg/ml, in glass, Teflon and polyethylene containers, leads to losses by adsorption. Electrochemical reduction of mercury to the metal, and subsequent volatilization, is postulated as the mechanism of loss from the samples studied during lyophilization. A method of instrumental neutron activation analysis, which obviates the above pretreatments, has been developed for mercury concentrations as low as 1 ng/ml

  10. Design of a novel instrument for active neutron interrogation of artillery shells.

    Directory of Open Access Journals (Sweden)

    Camille Bélanger-Champagne

    Full Text Available The most common explosives can be uniquely identified by measuring the elemental H/N ratio with a precision better than 10%. Monte Carlo simulations were used to design two variants of a new prompt gamma neutron activation instrument that can achieve this precision. The instrument features an intense pulsed neutron generator with precise timing. Measuring the hydrogen peak from the target explosive is especially challenging because the instrument itself contains hydrogen, which is needed for neutron moderation and shielding. By iterative design optimization, the fraction of the hydrogen peak counts coming from the explosive under interrogation increased from [Formula: see text]% to [Formula: see text]% (statistical only for the benchmark design. In the optimized design variants, the hydrogen signal from a high-explosive shell can be measured to a statistics-only precision better than 1% in less than 30 minutes for an average neutron production yield of 109 n/s.

  11. Instrumental neutron activation analysis of soil sample

    International Nuclear Information System (INIS)

    Abdul Khalik Haji Wood.

    1983-01-01

    This paper describes the analysis of soil samples collected from 5 different location around Sungai Lui, Kajang, Selangor, Malaysia. These sample were taken at 22-24 cm from the top of the ground and were analysed using the techniques of Instrumental Neutron Activation Analysis (INAA). The analysis on soil sample taken above 22-24 cm level were done in order to determine if there is any variation in elemental contents at different sampling levels. The results indicate a wide variation in the contents of the samples. About 30 elements have been analysed. The major ones are Na, I, Cl, Mg, Al, K, Ti, Ca and Fe. Trace elements analysed were Ba, Sc, V, Cr, Mn, Ga, As, Zn, Br, Rb, Co, Hf, Zr, Th, U, Sb, Cs, Ce, Sm, Eu, Tb, Dy, Yb, Lu and La. (author)

  12. Benefits of using customized instrumentation in total knee arthroplasty: results from an activity-based costing model.

    Science.gov (United States)

    Tibesku, Carsten O; Hofer, Pamela; Portegies, Wesley; Ruys, C J M; Fennema, Peter

    2013-03-01

    The growing demand for total knee arthroplasty (TKA) associated with the efforts to contain healthcare expenditure by advanced economies necessitates the use of economically effective technologies in TKA. The present analysis based on activity-based costing (ABC) model was carried out to estimate the economic value of patient-matched instrumentation (PMI) compared to standard surgical instrumentation in TKA. The costs of the two approaches, PMI and standard instrumentation in TKA, were determined by the use of ABC which measures the cost of a particular procedure by determining the activities involved and adding the cost of each activity. Improvement in productivity due to increased operating room (OR) turn-around times was determined and potential additional revenue to the hospital by the efficient utilization of gained OR time was estimated. Increased efficiency in the usage of OR and utilization of surgical trays were noted with patient-specific approach. Potential revenues to the hospital were estimated with the use of PMI by efficient utilization of time saved in OR. Additional revenues of 78,240 per year were estimated considering utilization of gained OR time to perform surgeries other than TKA. The analysis suggests that use of PMI in TKA is economically effective when compared to standard instrumentation.

  13. A new informant-based questionnaire for instrumental activities of daily living in dementia

    NARCIS (Netherlands)

    Sikkes, S.A.M.; de Lange-de Klerk, E.S.M.; Pijnenburg, Y.A.L.; Gillissen, F.; Romkes, R.; Knol, D.L.; Uitdehaag, B.M.J.; Scheltens, P.

    2012-01-01

    Background: Interference in everyday functioning is part of the diagnostic criteria for dementia. Questionnaires measuring "instrumental activities of daily living" (IADL) are used to measure this interference, but the psychometric quality of these questionnaires is often questioned. In addition,

  14. Imaging Reporters for Proteasome Activity Identify Tumor- and Metastasis-Initiating Cells

    Directory of Open Access Journals (Sweden)

    Amanda C. Stacer

    2015-08-01

    Full Text Available Tumor-initiating cells, also designated as cancer stem cells, are proposed to constitute a subpopulation of malignant cells central to tumorigenesis, metastasis, and treatment resistance. We analyzed the activity of the proteasome, the primary organelle for targeted protein degradation, as a marker of tumor- and metastasis-initiating cells. Using human and mouse breast cancer cells expressing a validated fluorescent reporter, we found a small subpopulation of cells with low proteasome activity that divided asymmetrically to produce daughter cells with low or high proteasome activity. Breast cancer cells with low proteasome activity had greater local tumor formation and metastasis in immunocompromised and immunocompetent mice. To allow flexible labeling of cells, we also developed a new proteasome substrate based on HaloTag technology. Patient-derived glioblastoma cells with low proteasome activity measured by the HaloTag reporter show key phenotypes associated with tumor-initiating cells, including expression of a stem cell transcription factor, reconstitution of the original starting population, and enhanced neurosphere formation. We also show that patient-derived glioblastoma cells with low proteasome activity have higher frequency of tumor formation in mouse xenografts. These studies support proteasome function as a tool to investigate tumor- and metastasis-initiating cancer cells and a potential biomarker for outcomes in patients with several different cancers.

  15. Multi-instrument assessment of physical activity in female office workers

    Directory of Open Access Journals (Sweden)

    Sema Can

    2016-12-01

    Full Text Available Objectives: The aim of this study was to examine the multi-instrument assessment of physical activity in female office workers. Material and Methods: Fifty healthy women (age (mean ± standard deviation: 34.8±5.9 years, body height: 158±0.4 cm, body weight: 61.8±7.5 kg, body mass index: 24.6±2.7 kg/m2 workers from the same workplace volunteered to participate in the study. Physical activity was measured with the 7-day Physical Activity Assessment Questionnaire (7-d PAAQ, an objective multi-sensor armband tool, and also a waist-mounted pedometer, which were both worn for 7 days. Results: A significant correlation between step numbers measured by armband and pedometer was observed (r = 0.735, but the step numbers measured by these 2 methods were significantly different (10 941±2236 steps/ day and 9170±2377 steps/day, respectively; p < 0.001. There was a weak correlation between the value of 7-d PAAQ total energy expenditure and the value of armband total energy expenditure (r = 0.394, p = 0.005. However, total energy expenditure values measured by armband and 7-d PAAQ were not significantly different (2081±370 kcal/ day and 2084±197 kcal/day, respectively; p = 0.96. In addition, physical activity levels (average daily metabolic equivalents (MET measured by armband and 7-d PAAQ were not significantly different (1.45±0.12 MET/day and 1.47±0.24 MET/day, respectively; p = 0.44. Conclusions: The results of this study showed that the correlation between pedometer and armband measurements was higher than that between armband measurements and 7-d PAAQ selfreports. Our results suggest that none of the assessment methods examined here, 7-d PAAQ, pedometer, or armband, is sufficient when used as a single tool for physical activity level determination. Therefore, multi-instrument assessment methods are preferable. Int J Occup Med Environ Health 2016;29(6:937–945

  16. Instrumental neutron activation analysis as a routine method for rock analysis

    International Nuclear Information System (INIS)

    Rosenberg, R.J.

    1977-06-01

    Instrumental neutron activation methods for the analysis of geological samples have been developed. Special emphasis has been laid on the improvement of sensitivity and accuracy in order to maximize tha quality of the analyses. Furthermore, the procedures have been automated as far as possible in order to minimize the cost of the analysis. A short review of the basic literature is given followed by a description of the principles of the method. All aspects concerning the sensitivity are discussed thoroughly in view of the analyst's possibility of influencing them. Experimentally determined detection limits for Na, Al, K, Ca, Sc, Cr, Ti, V, Mn, Fe, Ni, Co, Rb, Zr, Sb, Cs, Ba, La, Ce, Nd, Sm, Eu, Gd, Tb, Dy, Yb, Lu, Hf, Ta, Th and U are given. The errors of the method are discussed followed by actions taken to avoid them. The most significant error was caused by flux deviation, but this was avoided by building a rotating sample holder for rotating the samples during irradiation. A scheme for the INAA of 32 elements is proposed. The method has been automated as far as possible and an automatic γ-spectrometer and a computer program for the automatic calculation of the results are described. Furthermore, a completely automated uranium analyzer based on delayed neutron counting is described. The methods are discussed in view of their applicability to rock analysis. It is stated that the sensitivity varies considerably from element to element and instrumental activation analysis is an excellent method for the analysis of some specific elements like lanthanides, thorium and uranium but less so for many other elements. The accuracy is good varying from 2% to 10% for most elements. Instrumental activation analysis for most elements is rather an expensive method there being, however, a few exceptions. The most important of these is uranium. The analysis of uranium by delayed neutron counting is an inexpensive means for the analysis of large numbers of samples needed for

  17. Measurement of activity limitations and participation restrictions: examination of ICF-linked content and scale properties of the FIM and PC-PART instruments.

    Science.gov (United States)

    Darzins, Susan W; Imms, Christine; Di Stefano, Marilyn

    2017-05-01

    To explore the operationalization of activity and participation-related measurement constructs through comparison of item phrasing, item response categories and scoring (scale properties) for two separate instruments targeting activities of daily living. Personal Care Participation Assessment and Resource Tool (PC-PART) item content was linked to ICF categories using established linking rules. Previously reported ICF-linked FIM content categories and ICF-linked PC-PART content categories were compared to identify common ICF categories between the instruments. Scale properties of both instruments were compared using a patient scenario to explore the instruments' separate measurement constructs. The PC-PART and FIM shared 15 of the 53 level two ICF-linked categories identified across both instruments. Examination of the instruments' scale properties for items with overlapping ICF content, and exploration through a patient scenario, provided supportive evidence that the instruments measure different constructs. While the PC-PART and FIM share common ICF-linked content, they measure separate constructs. Measurement construct was influenced by the instruments' scale properties. The FIM was observed to measure activity limitations and the PC-PART measured participation restrictions. Scrutiny of instruments' scale properties in addition to item content is critical in the operationalization of activity and participation-related measurement constructs. Implications for Rehabilitation When selecting outcome measures for use in rehabilitation it is necessary to examine both the content of the instruments' items and item phrasing, response categories and scoring, to clarify the construct being measured. Measurement of activity limitations as well as participation restrictions in activities of daily living required for community life provides a more comprehensive measurement of rehabilitation outcomes than measurement of either construct alone. To measure the effects of

  18. Analysis of atmospheric particulate samples via instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Greenberg, R.R.

    1990-01-01

    Instrumental neutron activation analysis (INAA) is a powerful analytical technique for the elemental characterization of atmospheric particulate samples. It is a true multielement technique with adequate sensitivity to determine 30 to 40 elements in a sample of atmospheric particulate material. Its nondestructive nature allows sample reanalysis by the same or a different analytical technique. In this paper as an example of the applicability of INAA to the study of atmospheric particulate material, a study of the emissions from municipal incinerators is described

  19. Troubleshooting in nuclear instruments

    International Nuclear Information System (INIS)

    1987-06-01

    This report on troubleshooting of nuclear instruments is the product of several scientists and engineers, who are closely associated with nuclear instrumentation and with the IAEA activities in the field. The text covers the following topics: Preamplifiers, amplifiers, scalers, timers, ratemeters, multichannel analyzers, dedicated instruments, tools, instruments, accessories, components, skills, interfaces, power supplies, preventive maintenance, troubleshooting in systems, radiation detectors. The troubleshooting and repair of instruments is illustrated by some real examples

  20. Instrumental neutron activation analysis of brewer's yeast

    International Nuclear Information System (INIS)

    Bergerioux, C.; Zikovsky, L.

    1978-01-01

    Instrumental neutron activation was used for the determination of 23 trace and minor elements in 4 different samples of brewer's yeast. Detection limits vary from 2 ppb to 100 ppm. The following average concentrations were found (ppm, dry weight): Al 597, Br 0.36, Cl 1473, Co 0.21, Cu 19, Fe 285, K 16400, Mg 1355, Mn 8.4, Na 2330, Rb 19, Sb 0.053, Se 1.2, V 2.2 and Zn 80. NBS standard 1569 was also analyzed and the following concentrations (in ppm) were measured: Al 2300, Br 0.65, Ce 0.23, Cl 460, Co 0.26, Cr 2.12, Cu 11, Fe 707, Gd 7.1, Hf 0.13, K 15500, Mg 1780, Mn 7, Na 510, Rb 16, Sb 0.075, Sc 0.18, Se 0.92, Th 3.7, Ti 38, U 0.49, V 4.1 and Zn 70. (author)

  1. Electromyographic Pattern during Gait Initiation Differentiates Yoga Practitioners among Physically Active Older Subjects

    Directory of Open Access Journals (Sweden)

    Thierry Lelard

    2017-06-01

    Full Text Available During gait initiation, postural adjustments are needed to deal with balance and movement. With aging, gait initiation changes and reflects functional degradation of frailty individuals. However, physical activities have demonstrated beneficial effects of daily motor tasks. The aim of our study was to compare center of pressure (COP displacement and ankle muscle co-activation during gait initiation in two physically active groups: a group of walkers (n = 12; mean age ± SD 72.6 ± 3.2 years and a yoga group (n = 11; 71.5 ± 3.8 years. COP trajectory and electromyography of leg muscles were recorded simultaneously during five successive trials of gait initiation. Our main finding was that yoga practitioners had slower COP displacements (p < 0.01 and lower leg muscles % of coactivation (p < 0.01 in comparison with walkers. These parameters which characterized gait initiation control were correlated (r = 0.76; p < 0.01. Our results emphasize that lengthy ankle muscle co-activation and COP path in gait initiation differentiate yoga practitioners among physically active subjects.

  2. TECHNOLOGIES OF INITIATING STUDENTS INTO INDEPENDENT (SELF-GUIDED ACTIVITY IN SUPPLEMENTARY DISTANCE LEARNING

    Directory of Open Access Journals (Sweden)

    Irina V. Abakumova

    2016-12-01

    Full Text Available The research in question investigates the technologies of initiating independent activity within the framework of distance learning and their psychological aspects. The authors’ classification of educational technologies of initiating students into independent cognitive activity is presented. Such technologies utilize various psychological mechanisms of exciting students’ cognitive interest, intensifying cognitive processes, developing independent activity skills, and, as a result, increase motivation for independent activity and learning on the whole. These include such types of technologies as developmental technologies, interactive technologies, technologies of information transfer, technologies of meaning-making initiation. The research of the attitude of distance learning educators to independent activity of students and the content of the academic courses were done at Moodle-based education programs. The findings show the differences in retention rate among distance learning educators whose competence in terms of initiating students into independent (self-guided activity varies. It’s emphasized that interactive lectures, videoconferences, audio-visual aids, interactive seminars, glossaries, interactive tests are considered the most efficient technologies in initiating students into independent (self-guided activity. The obtained results have made it possible to stress the developmental effect of distance learning technologies and the technologies of initiating students into independent (self-guided activity in various psychic spheres of students: cognitive, individual, emotional. We mention the changes in motivational sphere of students and their meaning-making activity. In the course of correct development of distance learning we notice the development of voluntary and nonvoluntary cognitive activity. A student starts actively participating in educational process, he becomes the creator of his own world.

  3. The Effects of Reflective Activities on Skill Adaptation in a Work-Related Instrumental Learning Setting

    Science.gov (United States)

    Roessger, Kevin M.

    2014-01-01

    In work-related instrumental learning contexts, the role of reflective activities is unclear. Kolb's experiential learning theory and Mezirow's transformative learning theory predict skill adaptation as an outcome. This prediction was tested by manipulating reflective activities and assessing participants' response and error rates during novel…

  4. Instrumentation development

    International Nuclear Information System (INIS)

    Ubbes, W.F.; Yow, J.L. Jr.

    1988-01-01

    Instrumentation is developed for the Civilian Radioactive Waste Management Program to meet several different (and sometimes conflicting) objectives. This paper addresses instrumentation development for data needs that are related either directly or indirectly to a repository site, but does not touch on instrumentation for work with waste forms or other materials. Consequently, this implies a relatively large scale for the measurements, and an in situ setting for instrument performance. In this context, instruments are needed for site characterization to define phenomena, develop models, and obtain parameter values, and for later design and performance confirmation testing in the constructed repository. The former set of applications is more immediate, and is driven by the needs of program design and performance assessment activities. A host of general technical and nontechnical issues have arisen to challenge instrumentation development. Instruments can be classed into geomechanical, geohydrologic, or other specialty categories, but these issues cut across artificial classifications. These issues are outlined. Despite this imposing list of issues, several case histories are cited to evaluate progress in the area

  5. Development and initial validation of an instrument to assess stressors among South African sports coaches.

    Science.gov (United States)

    Kubayi, Alliance; Toriola, Abel; Didymus, Faye

    2018-06-01

    The aim of this series of studies was to develop and initially validate an instrument to assess stressors among South African sports coaches. In study one, a preliminary pool of 45 items was developed based on existing literature and an expert panel was employed to assess the content validity and applicability of these items. In study two, the 32 items that were retained after study one were analysed using principal component analysis (PCA). The resultant factorial structure comprised four components: environmental stressors, performance stressors, task-related stressors, and athlete stressors. These four components were made up of 26 items and, together, the components and items comprised the provisional Stressors in Sports Coaching Questionnaire (SSCQ). The results show that the SSCQ demonstrates acceptable internal consistency (.73-.89). The findings provide preliminary evidence that SSCQ is a valid tool to assess stressors among South African sports coaches.

  6. Certification of biological reference materials by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Lanjewar, Mamata R.; Lanjewar, R.B.

    2014-01-01

    A multielemental instrumental neutron activation analysis (INAA) method by short and long irradiation has been employed for the determination of 21 minor and trace elements in two standard Reference Materials P-RBF and P-WBF from Institute of Radioecology and Applied Nuclear Techniques ,Czechoslovakia. Also some biological standards such as Bowen's kale, cabbage leaves (Poland) including wheat and rice flour samples of local origin were analysed. It is suggested that INAA is an ideal method for the certification of Reference Materials of Biological Matrices. (author)

  7. Comparison of trunk activity during gait initiation and walking in humans.

    Directory of Open Access Journals (Sweden)

    Jean-Charles Ceccato

    Full Text Available To understand the role of trunk muscles in maintenance of dynamic postural equilibrium we investigate trunk movements during gait initiation and walking, performing trunk kinematics analysis, Erector spinae muscle (ES recordings and dynamic analysis. ES muscle expressed a metachronal descending pattern of activity during walking and gait initiation. In the frontal and horizontal planes, lateroflexion and rotation occur before in the upper trunk and after in the lower trunk. Comparison of ES muscle EMGs and trunk kinematics showed that trunk muscle activity precedes corresponding kinematics activity, indicating that the ES drive trunk movement during locomotion and thereby allowing a better pelvis mobilization. EMG data showed that ES activity anticipates propulsive phases in walking with a repetitive pattern, suggesting a programmed control by a central pattern generator. Our findings also suggest that the programs for gait initiation and walking overlap with the latter beginning before the first has ended.

  8. German activities in optical space instrumentation

    Science.gov (United States)

    Hartmann, G.

    2018-04-01

    In the years of space exploration since the mid-sixties, a wide experience in optical space instrumentation has developed in Germany. This experience ranges from large telescopes in the 1 m and larger category with the accompanying focal plane detectors and spectrometers for all regimes of the electromagnetic spectrum (infrared, visible, ultraviolet, x-rays), to miniature cameras for cometary and planetary explorations. The technologies originally developed for space science. are now also utilized in the fields of earth observation and even optical telecommunication. The presentation will cover all these areas, with examples for specific technological or scientific highlights. Special emphasis will be given to the current state-of-the-art instrumentation technologies in scientific institutions and industry, and to the future perspective in approved and planned projects.

  9. Assessing research activity and capacity of community-based organizations: development and pilot testing of an instrument.

    Science.gov (United States)

    Humphries, Debbie L; Carroll-Scott, Amy; Mitchell, Leif; Tian, Terry; Choudhury, Shonali; Fiellin, David A

    2014-01-01

    Although awareness of the importance of the research capacity of community-based organizations (CBOs) is growing, a uniform framework of the research capacity domains within CBOs has not yet been developed. To develop a framework and instrument (the Community REsearch Activity assessment Tool [CREAT]) for assessing the research activity and capacity of CBOs that incorporates awareness of the different data collection and analysis priorities of CBOs. We conducted a review of existing tools for assessing research capacity to identify key capacity domains. Instrument items were developed through an iterative process with CBO representatives and community researchers. The CREAT was then pilot tested with 30 CBOs. The four primary domains of the CREAT framework include 1) organizational support for research, 2) generalizable experiences, 3) research specific experiences, and 4) funding. Organizations reported a high prevalence of activities in the research-specific experiences domain, including conducting literature reviews (70%), use of research terminology (83%), and primary data collection (100%). Respondents see research findings as important to improve program and service delivery, and to seek funds for new programs and services. Funders, board members, and policymakers are the most important dissemination audiences. The work reported herein advances the field of CBO research capacity by developing a systematic framework for assessing research activity and capacity relevant to the work of CBOs, and by developing and piloting an instrument to assess activity in these domains.

  10. Instrument validation system of general application

    International Nuclear Information System (INIS)

    Filshtein, E.L.

    1990-01-01

    This paper describes the Instrument Validation System (IVS) as a software system which has the capability of evaluating the performance of a set of functionally related instrument channels to identify failed instruments and to quantify instrument drift. Under funding from Combustion Engineering (C-E), the IVS has been developed to the extent that a computer program exists whose use has been demonstrated. The initial development work shows promise for success and for wide application, not only to power plants, but also to industrial manufacturing and process control. Applications in the aerospace and military sector are also likely

  11. The instrumental neutron-activation analysis of granites from the Bushveld Complex

    International Nuclear Information System (INIS)

    Watterson, J.I.W.

    1978-01-01

    Three methods of instrumental neutron-activation analysis, 14MeV, reactor thermal, and reactor epithermal, are compared for the analysis of granites form the Bushveld Complex. A total of 34 elements can be determined in the granites by these methods. Samples from the Zaaiplaats area were analysed by thermal neutron activation, and 22 elements were determined in all of them. These elements were used to distinguish between the mineralized Bobbejaankop and Lease granites and the Main granite by the use of multivariate statistics. The Bobbejaankop granite appears as a more-differentaited rock carrying greater amounts of the incompatible elements than does the Main granite [af

  12. Interaction Effects of Happiness and Physical Activity on Smoking Initiation.

    Science.gov (United States)

    Torchyan, Armen A; BinSaeed, Abdulaziz A; Aleid, Yazeed S; Nagshbandi, Ahmed A; Almousa, Fahad; Papikyan, Satenik L; Gosadi, Ibrahim M

    2016-11-01

    Our aim was to assess the potential relationships among happiness, physical activity, and smoking initiation among undergraduate medical students in Saudi Arabia. We performed a cross-sectional study of randomly selected first- to fifth-year undergraduate medical students. Smoking initiation was defined as "ever trying smoking a cigarette, waterpipe, cigar/cigarillo, or other type of tobacco, even one or 2 puffs." The short scale Oxford Happiness Questionnaire was used to assess each student's happiness. Multivariate logistic regression analysis was performed. Of the 406 students surveyed (208 boys, 198 girls), 86 (21.1%) had initiated smoking. We found an interaction between physical activity (PA) and happiness on smoking initiation (p-interaction = .012). Among boys with low levels of PA, lower levels of happiness were associated with a greater likelihood of smoking initiation (OR = 5.8, 95%CI = 1.9 - 17.5). Also, high levels of PA increased the chance of smoking initiation among male students with high levels of happiness (OR = 5.6, 95%CI = 2.1 - 14.5). Our results suggest that young men with low levels of happiness and low levels of PA, as well as high levels of PA and high levels of happiness, may be targeted as a priority population in tobacco control intervention programs.

  13. Instrument Qualification of Custom Fabricated Water Activity Meter for Hot Cell Use

    Energy Technology Data Exchange (ETDEWEB)

    McCoskey, Jacob K. [Hanford Site (HNF), Richland, WA (United States)

    2014-01-22

    This report describes a custom fabricated water activity meter and the results of the qualification of this meter as described in the laboratory test plan LAB-PLN-11-00012, Testing and Validation of an Enhanced Acquisition and Control System. It was calibrated against several NaOH solutions of varying concentrations to quantify the accuracy and precision of the instrument at 20 °C and 60 °C. Also, a schematic and parts list of the equipment used to make the water activity meter will be presented in this report.

  14. Salvinia auriculata: Aquatic bioindicator studied by instrumental neutron activation analysis (INAA)

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira Soares, Daniel Cristian; Figueiredo de Oliveira, Ester [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN), Avenida Antonio Carlos, 6627 Pampulha, CEP 30123-970 Belo Horizonte, Minas Gerais (Brazil); Fatima Silva, Gracia Divina de; Duarte, Lucienir Pains [Departamento de Quimica, ICEx, Nucleo de estudos de Plantas Medicinais (NEPLAM), Universidade Federal de Minas Gerais, Avenida Antonio Carlos, 6627 Pampulha, 31270-901 Belo Horizonte, Minas Gerais (Brazil); Pott, Vali Joana [Empresa Brasileira de Agropecuaria (EMBRAPA), BR 262 km 4, Caixa Postal 154, CEP 79002-970 Campo Grande, Mato Grosso do Sul (Brazil); Vieira Filho, Sidney Augusto [Escola de Farmacia, DEFAR, Universidade Federal de Ouro Preto, Rua Costa Sena, 171, CEP 35400-000 Ouro Preto, Minas Gerais (Brazil)], E-mail: bibo@ef.ufop.br

    2008-05-15

    Through instrumental neutron activation analysis (INAA) the elemental chemical composition of Salvinia auriculata and Ouro Preto city public water was determined. Elements Ce, Th, Cr, Hf, Sb, Sc, Rb, Fe, Zn, Co, Au, La and Br were quantified. High chromium concentration was determined in this plant. But, chromium was determined only in low concentrations in the water. The results indicate the great capacity of this plant to absorb and accumulate inorganic elements.

  15. The integration of corporate social responsibility (CSR) initiatives into business activities

    DEFF Research Database (Denmark)

    Knudsen, Jette Steen

    2013-01-01

    While proponents of corporate social responsibility (CSR) have suggested that CSR initiatives should be integrated into mainstream business activities as 'strategic CSR' or 'shared value', research is lacking that explores how CSR programmes are integrated in companies. This paper compares CSR...... initiatives with human resource management (HRM) activities, which have a longer tradition of being integrated into company strategy. The focus is on gender diversity and CSR in a US multinational corporation (MNC). The MNC sees gender diversity as an integral part of business activities. In contrast, the MNC...

  16. Origins, transformations and key foci in instrumental genesis

    DEFF Research Database (Denmark)

    Tamborg, Andreas Lindenskov

    This paper investigates the origins of the instrumental genesis and instrumental orchestrations frameworks. This is done by reviewing instrumented activity situations, instrumental genesis, and instrumental orchestrations with the purpose of identifying their epistemological assumptions, what the...... and instrumental orchestrations have potential shortcomings since the technologies that currently exist in school contexts are rather different from the technologies instrumental genesis was originally developed to study.......This paper investigates the origins of the instrumental genesis and instrumental orchestrations frameworks. This is done by reviewing instrumented activity situations, instrumental genesis, and instrumental orchestrations with the purpose of identifying their epistemological assumptions, what...

  17. On initial Brain Activity Mapping of episodic and semantic memory code in the hippocampus.

    Science.gov (United States)

    Tsien, Joe Z; Li, Meng; Osan, Remus; Chen, Guifen; Lin, Longian; Wang, Phillip Lei; Frey, Sabine; Frey, Julietta; Zhu, Dajiang; Liu, Tianming; Zhao, Fang; Kuang, Hui

    2013-10-01

    It has been widely recognized that the understanding of the brain code would require large-scale recording and decoding of brain activity patterns. In 2007 with support from Georgia Research Alliance, we have launched the Brain Decoding Project Initiative with the basic idea which is now similarly advocated by BRAIN project or Brain Activity Map proposal. As the planning of the BRAIN project is currently underway, we share our insights and lessons from our efforts in mapping real-time episodic memory traces in the hippocampus of freely behaving mice. We show that appropriate large-scale statistical methods are essential to decipher and measure real-time memory traces and neural dynamics. We also provide an example of how the carefully designed, sometime thinking-outside-the-box, behavioral paradigms can be highly instrumental to the unraveling of memory-coding cell assembly organizing principle in the hippocampus. Our observations to date have led us to conclude that the specific-to-general categorical and combinatorial feature-coding cell assembly mechanism represents an emergent property for enabling the neural networks to generate and organize not only episodic memory, but also semantic knowledge and imagination. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.

  18. New highly sensitive method of simultaneous instrumental neutron activation determination of 12 microelements in vine

    International Nuclear Information System (INIS)

    Shoniya, N.I.

    1977-01-01

    The main principles and methods of simultaneous multi-element instrumental neutron activation determination of microelements in vine seeds are presented. The methods permit to carry out quantitative evaluation for every single corn of the seeds. It is shown that the method of instrumental neutron activation analysis with the utilization of a semiconductor spectrometer of high resolution and mini electronic computer permit to carry out serial determinations of 12 microelements in the individual corns of vine seeds of different sorts. This method will permit to determine the missing or excess content of this or that biologically important microelement in soils, plants, fruit and genetic material - seeds, and so to determine the optimum conditions of growing plants by applying microelement fertilizers as extra nutrient means

  19. Photon Activation Analysis Of Light Elements Using 'Non-Gamma' Radiation Spectroscopy - The Instrumental Determination Of Phosphorus

    International Nuclear Information System (INIS)

    Segebade, Christian; Goerner, Wolf

    2011-01-01

    Unlike metal determinations the analysis of light elements (e.g., carbon, oxygen, phosphorus) is frequently problematic, in particular if analysed instrumentally. In photon activation analysis (PAA) the respective activation products do not emit gamma radiation in the most cases. Usually, annihilation quanta counting and subsequent decay curve analysis have been used for determinations of C, N, O, and F. However, radiochemical separation of the respective radioisotopes mostly is indispensable. For several reasons, some of the light elements cannot be analysed following this procedure, e.g. phosphorus. In this contribution the instrumental PAA of phosphorus in organic matrix by activation with bremsstrahlung of an electron linear accelerator and subsequent beta spectroscopy is described. The accuracy of the results was excellent as obtained by analysis of a BCR Reference Material.

  20. Development and initial validation of the Pharmacist Frequency of Interprofessional Collaboration Instrument (FICI-P) in primary care.

    Science.gov (United States)

    Van, Connie; Costa, Daniel; Mitchell, Bernadette; Abbott, Penny; Krass, Ines

    2012-01-01

    Existing validated measures of pharmacist-physician collaboration focus on measuring attitudes toward collaboration and do not measure frequency of collaborative interactions. To develop and validate an instrument to measure the frequency of collaboration between pharmacists and general practitioners (GPs) from the pharmacist's perspective. An 11-item Pharmacist Frequency of Interprofessional Collaboration Instrument (FICI-P) was developed and administered to 586 pharmacists in 8 divisions of general practice in New South Wales, Australia. The initial items were informed by a review of the literature in addition to interviews of pharmacists and GPs. Items were subjected to principal component and Rasch analyses to determine each item's and the overall measure's psychometric properties and for any needed refinements. Two hundred and twenty four (38%) of pharmacist surveys were completed and returned. Principal component analysis suggested removal of 1 item for a final 1-factor solution. The refined 10-item FICI-P demonstrated internal consistency reliability at Cronbach's alpha=0.90. After collapsing the original 5-point response scale to a 4-point response scale, the refined FICI-P demonstrated fit to the Rasch model. Criterion validity of the FICI-P was supported by the correlation of FICI-P scores with scores on a previously validated Physician-Pharmacist Collaboration Instrument. Validity was also supported by predicted differences in FICI-P scores between subgroups of respondents stratified on age, colocation with GPs, and interactions during the intern-training period. The refined 10-item FICI-P was shown to have good internal consistency, criterion validity, and fit to the Rasch model. The creation of such a tool may allow for the measure of impact in the evaluation of interventions designed to improve interprofessional collaboration between GPs and pharmacists. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Novel mass spectrometric instrument for gaseous and particulate characterization and monitoring

    International Nuclear Information System (INIS)

    Coggiola, M.J.

    1994-02-01

    SRI International will develop a unique new instrument that will be capable of providing real-time (<1 minute), quantitative, chemical characterization of gaseous and particulate pollutants generated from DOE waste cleanup activities. The instrument will be capable of detecting and identifying volatile organic compounds, polynuclear aromatic hydrocarbons, heavy metals, and transuranic species released during waste cleanup activities. The instrument will be unique in its ability to detect and quantify in real-time these diverse pollutants in both vapor and particulate form. The instrument to be developed under this program will consist of several major components: (1) an isokinetic sampler capable of operating over a wide range of temperatures (up to 500 K) and flow rates; (2) a high pressure to low pressure transition and sampling region that efficiently separates particles from vapor-phase components for separate, parallel analyses; (3) two small mass spectrometers, one optimized for organic analysis using a unique field ionization source and one optimized for particulate characterization using thermal pyrolysis and electron-impact ionization (EI); and (4) a powerful personal computer for control and data acquisition. Initially, the instrument will be developed for targeted use in conjunction with the K-1435 Toxic Substances Control Act (TSCA) incinerator at the Oak Ridge National Laboratory K-25 site. Ultimately, the instrument will be designed to operate in the field at any cleanup site, located close to the stack or process vent, providing the plant operations personnel with real-time information and alarm capabilities. In addition, this instrument will be very broadly applicable for cleanup or sampling, for example, any time contaminated soil is moved or disturbed

  2. ECLSS Integration Analysis: Advanced ECLSS Subsystem and Instrumentation Technology Study for the Space Exploration Initiative

    Science.gov (United States)

    1990-01-01

    In his July 1989 space policy speech, President Bush proposed a long range continuing commitment to space exploration and development. Included in his goals were the establishment of permanent lunar and Mars habitats and the development of extended duration space transportation. In both cases, a major issue is the availability of qualified sensor technologies for use in real-time monitoring and control of integrated physical/chemical/biological (p/c/b) Environmental Control and Life Support Systems (ECLSS). The purpose of this study is to determine the most promising instrumentation technologies for future ECLSS applications. The study approach is as follows: 1. Precursor ECLSS Subsystem Technology Trade Study - A database of existing and advanced Atmosphere Revitalization (AR) and Water Recovery and Management (WRM) ECLSS subsystem technologies was created. A trade study was performed to recommend AR and WRM subsystem technologies for future lunar and Mars mission scenarios. The purpose of this trade study was to begin defining future ECLSS instrumentation requirements as a precursor to determining the instrumentation technologies that will be applicable to future ECLS systems. 2. Instrumentation Survey - An instrumentation database of Chemical, Microbial, Conductivity, Humidity, Flowrate, Pressure, and Temperature sensors was created. Each page of the sensor database report contains information for one type of sensor, including a description of the operating principles, specifications, and the reference(s) from which the information was obtained. This section includes a cursory look at the history of instrumentation on U.S. spacecraft. 3. Results and Recommendations - Instrumentation technologies were recommended for further research and optimization based on a consideration of both of the above sections. A sensor or monitor technology was recommended based on its applicability to future ECLS systems, as defined by the ECLSS Trade Study (1), and on whether its

  3. Californium interrogation prompt neutron (CIPN) instrument for non-destructive assay of spent nuclear fuel—Design concept and experimental demonstration

    International Nuclear Information System (INIS)

    Henzlova, D.; Menlove, H.O.; Rael, C.D.; Trellue, H.R.; Tobin, S.J.; Park, Se-Hwan; Oh, Jong-Myeong; Lee, Seung-Kyu; Ahn, Seong-Kyu; Kwon, In-Chan; Kim, Ho-Dong

    2016-01-01

    This paper presents results of the first experimental demonstration of the Californium Interrogation Prompt Neutron (CIPN) instrument developed within a multi-year effort launched by the Next Generation Safeguards Initiative Spent Fuel Project of the United States Department of Energy. The goals of this project focused on developing viable non-destructive assay techniques with capabilities to improve an independent verification of spent fuel assembly characteristics. For this purpose, the CIPN instrument combines active and passive neutron interrogation, along with passive gamma-ray measurements, to provide three independent observables. This paper describes the initial feasibility demonstration of the CIPN instrument, which involved measurements of four pressurized-water-reactor spent fuel assemblies with different levels of burnup and two initial enrichments. The measurements were performed at the Post-Irradiation Examination Facility at the Korea Atomic Energy Institute in the Republic of Korea. The key aim of the demonstration was to evaluate CIPN instrument performance under realistic deployment conditions, with the focus on a detailed assessment of systematic uncertainties that are best evaluated experimentally. The measurements revealed good positioning reproducibility, as well as a high degree of insensitivity of the CIPN instrument's response to irregularities in a radial burnup profile. Systematic uncertainty of individual CIPN instrument signals due to assembly rotation was found to be <4.5%, even for assemblies with fairly extreme gradients in the radial burnup profile. These features suggest that the CIPN instrument is capable of providing a good representation of assembly average characteristics, independent of assembly orientation in the instrument.

  4. Californium interrogation prompt neutron (CIPN) instrument for non-destructive assay of spent nuclear fuel—Design concept and experimental demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Henzlova, D., E-mail: henzlova@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Menlove, H.O.; Rael, C.D.; Trellue, H.R.; Tobin, S.J. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Park, Se-Hwan; Oh, Jong-Myeong; Lee, Seung-Kyu; Ahn, Seong-Kyu; Kwon, In-Chan; Kim, Ho-Dong [Korea Atomic Energy Research Institute, Daejeong (Korea, Republic of)

    2016-01-11

    This paper presents results of the first experimental demonstration of the Californium Interrogation Prompt Neutron (CIPN) instrument developed within a multi-year effort launched by the Next Generation Safeguards Initiative Spent Fuel Project of the United States Department of Energy. The goals of this project focused on developing viable non-destructive assay techniques with capabilities to improve an independent verification of spent fuel assembly characteristics. For this purpose, the CIPN instrument combines active and passive neutron interrogation, along with passive gamma-ray measurements, to provide three independent observables. This paper describes the initial feasibility demonstration of the CIPN instrument, which involved measurements of four pressurized-water-reactor spent fuel assemblies with different levels of burnup and two initial enrichments. The measurements were performed at the Post-Irradiation Examination Facility at the Korea Atomic Energy Institute in the Republic of Korea. The key aim of the demonstration was to evaluate CIPN instrument performance under realistic deployment conditions, with the focus on a detailed assessment of systematic uncertainties that are best evaluated experimentally. The measurements revealed good positioning reproducibility, as well as a high degree of insensitivity of the CIPN instrument's response to irregularities in a radial burnup profile. Systematic uncertainty of individual CIPN instrument signals due to assembly rotation was found to be <4.5%, even for assemblies with fairly extreme gradients in the radial burnup profile. These features suggest that the CIPN instrument is capable of providing a good representation of assembly average characteristics, independent of assembly orientation in the instrument.

  5. Mercury determination in dentist's hair and nails by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Mazzilli, B.; Munita, C.S.

    1986-01-01

    The mercury in scalp hair and fingernails of a group of dentists who usually handle with this toxic element in their profession is determined. The results were obtained by instrumental neutron activation analysis. The experimental procedure was based on the evaluation of the 197 Hg photopeak area, whose half life is 65h. After at a neutron fluxo of 5x10 12 n.cm -2 .sec -1 , the activity of the samples were measured by using a solid state Ge (Li) detector coupled to a 4.096 channel pulse height analyser. (M.A.C.) [pt

  6. syk kinase activation by a src kinase-initiated activation loop phosphorylation chain reaction

    Science.gov (United States)

    El-Hillal, O.; Kurosaki, T.; Yamamura, H.; Kinet, J.-P.; Scharenberg, A. M.

    1997-01-01

    Activation of the syk tyrosine kinase occurs almost immediately following engagement of many types of antigen receptors, including Fc receptors, but the mechanism through which syk is activated is currently unclear. Here we demonstrate that Fc receptor-induced syk activation occurs as the result of phosphorylation of the syk activation loop by both src family kinases and other molecules of activated syk, suggesting that syk activation occurs as the result of a src kinase-initiated activation loop phosphorylation chain reaction. This type of activation mechanism predicts that syk activation would exhibit exponential kinetics, providing a potential explanation for its rapid and robust activation by even weak antigen receptor stimuli. We propose that a similar mechanism may be responsible for generating rapid activation of other cytoplasmic tyrosine kinases, such as those of the Bruton tyrosine kinase/tec family, as well. PMID:9050880

  7. Intercomparison of active, passive and continuous instruments for radon and radon progeny measurements in the EML chamber and test facility

    International Nuclear Information System (INIS)

    George, A.C.; Knutson, E.O.; Tu, K.W.; Fisenne, I.M.

    1995-12-01

    The results from the May 1995 Intercomparison of Active, Passive and Continuous Instruments for Radon and Radon Progeny Measurement conducted in the EML radon exposure and test facility are presented. Represented were 13 participants that measure radon with open faced and diffusion barrier activated carbon collectors, 10 with nuclear alpha track detectors, 9 with short-term and long-term electret/ionization chambers, and 13 with active and passive commercial electronic continuous monitors. For radon progeny, there were four participants that came in person to take part in the grab sampling methodology for measuring individual radon progeny and the potential alpha energy concentration (PAEC). There were 11 participants with continuous and integrating commercial electronic instruments that are used for measuring the PAEC. The results indicate that all the tested instruments that measure radon fulfill their intended purpose. All instruments and methods used for grab sampling for radon progeny did very well. However, most of the continuous and integrating electronic instruments used for measuring the PAEC or working level appear to underestimate the potential risk from radon progeny when the concentration of particles onto which the radon progeny are attached is -3

  8. Status of safeguards instrumentation

    International Nuclear Information System (INIS)

    Higinbotham, W.A.

    The International Atomic Energy Agency is performing safeguards at some nuclear power reactors, 50 bulk processing facilities, and 170 research facilities. Its verification activities require the use of instruments to measure nuclear materials and of surveillance instruments to maintain continuity of knowledge of the locations of nuclear materials. Instruments that are in use and under development to measure weight, volume, concentration, and isotopic composition of nuclear materials, and the major surveillance instruments, are described in connection with their uses at representative nuclear facilities. The current status of safeguards instrumentation and the needs for future development are discussed

  9. Invited Article: First Flight in Space of a Wide-field-of-view Soft X-Ray Imager Using Lobster-Eye Optics: Instrument Description and Initial Flight Results

    Science.gov (United States)

    Collier, Michael; Porter, F. Scott; Sibeck, David G.; Carter, Jenny A.; Chiao, Meng P.; Chomay, Dennis J.; Cravens, Thomas E.; Galeazzi, Massiniliano; Keller, John; Koutroumpa, Dimitra

    2015-01-01

    We describe the development, launch into space, and initial results from a prototype wide eld-of-view (FOV) soft X-ray imager that employs Lobster-eye optics and targets heliophysics, planetary, and astrophysics science. The Sheath Transport Observer for the Redistribution of Mass (STORM) is the rst instrument using this type of optics launched into space and provides proof-of-concept for future ight instruments capable of imaging structures such as the terrestrial cusp, the entire dayside magnetosheath from outside the magnetosphere, comets, the moon, and the solar wind interaction with planetary bodies like Venus and Mars.

  10. Invited Article: First flight in space of a wide-field-of-view soft x-ray imager using lobster-eye optics: Instrument description and initial flight results.

    Science.gov (United States)

    Collier, Michael R; Porter, F Scott; Sibeck, David G; Carter, Jenny A; Chiao, Meng P; Chornay, Dennis J; Cravens, Thomas E; Galeazzi, Massimiliano; Keller, John W; Koutroumpa, Dimitra; Kujawski, Joseph; Kuntz, Kip; Read, Andy M; Robertson, Ina P; Sembay, Steve; Snowden, Steven L; Thomas, Nicholas; Uprety, Youaraj; Walsh, Brian M

    2015-07-01

    We describe the development, launch into space, and initial results from a prototype wide field-of-view soft X-ray imager that employs lobster-eye optics and targets heliophysics, planetary, and astrophysics science. The sheath transport observer for the redistribution of mass is the first instrument using this type of optics launched into space and provides proof-of-concept for future flight instruments capable of imaging structures such as the terrestrial cusp, the entire dayside magnetosheath from outside the magnetosphere, comets, the Moon, and the solar wind interaction with planetary bodies like Venus and Mars [Kuntz et al., Astrophys. J. (in press)].

  11. A Finescale Lagrangian Instrument System

    National Research Council Canada - National Science Library

    Toole, John

    2003-01-01

    ... from conventional, bottom-anchored moorings. An initial trial of the concept targeting the upper ocean was carried out off Bermuda in November 2001 with an instrument profiling between 12 and 28O-m depth...

  12. Traceability of radiation protection instruments

    Science.gov (United States)

    Hino, Y.; Kurosawa, T.

    2007-08-01

    Radiation protection instruments are used in daily measurement of dose and activities in workplaces and environments for safety management. The requirements for calibration certificates with traceability are increasing for these instruments to ensure the consistency and reliabilities of the measurement results. The present traceability scheme of radiation protection instruments for dose and activity measurements is described with related IEC/ISO requirements. Some examples of desirable future calibration systems with recent new technologies are also discussed to establish the traceability with reasonable costs and reliabilities.

  13. HTGR accident initiation and progression analysis status report. Volume VII. Occupational radiation exposures from gas-borne and plateout activities

    International Nuclear Information System (INIS)

    1976-01-01

    As a part of the Accident Initiation and Progression Analysis (AIPA) program, calculations were performed of the occupational dose rates and man-rem exposures from gas-borne and plateout activities in a reference 3000-MW(t) HTGR plant. The study included a preliminary survey to determine the most important contributors by operation or radiation source to the man-rem exposures. This survey was followed by detailed calculations for the most important cases. Median and 95 percent-confidence-level man-rem exposures per year were obtained for the gaseous activity in the containment building, moisture monitor system, analytic instrumentation, helium regeneration system, gas waste system, and reflector-block shipping. Median and 95 percent-confidence-level man-rem exposures per operation were obtained for the main-circulator removal, steam-generator tube plugging, and steam-generator removal and replacement. For each of these cases, the contributions to the man-rem exposures were calculated for the important isotopes

  14. The preparation of synthetic standards for use in instrumental neutron-activation analysis

    International Nuclear Information System (INIS)

    Eddy, B.T.; Watterson, J.I.W.; Erasmus, C.S.

    1979-01-01

    An account is given of the formulation and preparation of synthetic standards suitable for the routine analysis of minerals, ores, and ore concentrates by instrumental neutron activation. Fifteen standards were prepared, each containing from one to seven elements. The standards contain forty-four elements that produce isotopes with half-lives longer than 12 hours. An evaluation of the accuracy and precision of the method of preparation is given

  15. A survey of environmental exposure amongst locoshed workers by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Singh, V.K.N.; Garg, A.N.

    1995-01-01

    Instrumental neutron activation analysis (INAA) has been used for the determination of 16 elements in hair of locoshed workers (n=10) to study environmental exposure. A comparison of mean elemental contents with control (n=11) shows a significant enhancement for Cr, Th, Ca, Se and Na whereas Br and Sb show a declining trend. (author). 4 refs., 1 tab

  16. Radon-Instrumentation

    International Nuclear Information System (INIS)

    Moreno y Moreno, A.

    2003-01-01

    The presentation of the active and passive methods for radon, their identification and measure, instrumentation and characteristics are the objectives of this work. Active detectors: Active Alpha Cam Continuous Air Monitor, Model 758 of Victoreen, Model CMR-510 Continuous Radon Monitor of the Signature Femto-Tech. Passive detectors: SSNTD track detectors in solids Measurement Using Charcoal Canisters, disk of activated coal deposited in a metallic box Electrets Methodology. (Author)

  17. The response of some health physics instruments to sodium-24 and chlorine-38 activities in polythene man-phantoms and the human body

    International Nuclear Information System (INIS)

    Peabody, C.O.

    1963-12-01

    Measurements have been made of the response of five commonly used Health Physics instruments when held near polythene man-phantoms filled with aqueous solutions containing sodium-24 and chlorine-38 activities. The instruments discussed are the Type 1413A, 1597A and 1368A ratemeters, the E.M.I. PCM1 contamination monitor and the Type 1021C beta-gamma probe. The ratios of the whole-body chlorine-38 and sodium-24 activities are calculated for various periods of accidental human irradiation by neutrons. These ratios and the phantom results are used to estimate the response of the five instruments when held near the human body at various times after irradiation. The relative contributions of the chlorine-38 and sodium-24 to the instrument indications are listed. The tabulated data enable the instrument readings to be converted to whole-body sodium-24 activity at the time of irradiation. This may be used as a quick estimate of the degree of neutron irradiation. (author)

  18. Mild cognitive impairment and deficits in instrumental activities of daily living: a systematic review

    NARCIS (Netherlands)

    Jekel, K.; Damian, M.; Wattmo, C.; Hausner, L.; Bullock, R.; Connelly, P.J.; Dubois, B.; Eriksdotter, M.; Ewers, M.; Graessel, E.; Kramberger, M.G.; Law, E.; Mecocci, P.; Molinuevo, J.L.; Nygard, L.; Olde Rikkert, M.G.M.; Orgogozo, J.M.; Pasquier, F.; Peres, K.; Salmon, E.; Sikkes, S.A.; Sobow, T.; Spiegel, R.; Tsolaki, M.; Winblad, B.; Frolich, L.

    2015-01-01

    INTRODUCTION: There is a growing body of evidence that subtle deficits in instrumental activities of daily living (IADL) may be present in mild cognitive impairment (MCI). However, it is not clear if there are IADL domains that are consistently affected across patients with MCI. In this systematic

  19. Short version of the “instrument for assessment of stress in nursing students” in the Brazilian reality

    Directory of Open Access Journals (Sweden)

    Ana Lúcia Siqueira Costa

    2018-01-01

    Full Text Available ABSTRACT Goal: validate a short version of the Instrument for assessment of stress in nursing students in the Brazilian reality. Method: Methodological study conducted with 1047 nursing students from five Brazilian institutions, who answered the 30 items initially distributed in eight domains. Data were analyzed in the R Statistical Package and in the latent variable analysis, using exploratory and confirmatory factor analyses, Cronbach’s alpha and item-total correlation. Results: The short version of the instrument had 19 items distributed into four domains: Environment, Professional Training, Theoretical Activities and Performance of Practical Activities. The confirmatory analysis showed absolute and parsimony fit to the proposed model with satisfactory residual levels. Alpha values per factor ranged from 0.736 (Environment to 0.842 (Performance of Practical Activities. Conclusion: The short version of the instrument has construct validity and reliability for application to Brazilian nursing undergraduates at any stage of the course.

  20. Multielement analysis of Nigerian chewing sticks by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Asubiojo, O.I.; Guinn, V.P.

    1982-01-01

    In Nigeria, various parts of various species of native plants have long been used for dental hygiene, with reportedly considerable effectiveness. These materials are known as 'chewing sticks'. This study was an effort to ascertain whether any unusual trace element concentrations might be present in Nigerian chewing sticks. Results are presented for 17 elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Mn, Fe, Co, Zn, Br, Cs, La, Sm, Au) detected and measured in 12 species of such plants, via instrumental thermal-neutron activation analysis. (author)

  1. Validation of reported physical activity for cholesterol control using two different physical activity instruments

    Directory of Open Access Journals (Sweden)

    Amy Z Fan

    2009-08-01

    Full Text Available Amy Z Fan1, Sandra A Ham2, Shravani Reddy Muppidi3, Ali H Mokdad41Behavioral Surveillance Branch, Division of Adult and Community Health, National Center for Chronic Disease Prevention and Health Promotion; 2Physical Activity and Health Branch, Division of Nutrition, Physical Activity, and Obesity, National Center for Chronic Disease Prevention and Health Promotion, Centers for Disease Control and Prevention, Atlanta, GA, USA; 3College of Public Health, University of Georgia, Athens, GA, USA; 4Institute for Health Metrics and Evaluation, University of Washington, Seattle, WA, USAAbstract: The National Cholesterol Education Program recommends increasing physical activity to improve cholesterol levels and overall cardiovascular health. We examined whether US adults who reported increasing their physical activity to control or lower blood cholesterol following physician’s advice or on their own efforts had higher levels of physical activity than those who reported that they did not. We used data from the National Health and Nutrition Examination Survey 2003–2004, which implemented two physical activity assessment instruments. The physical activity questionnaire (PAQ assessed self-reported frequency, intensity, and duration of leisure-time, household, and transportation-related physical activity in the past month. Physical movement was objectively monitored using a waist accelerometer that assessed minute-by-minute intensity (counts of movement/minute during waking time over a 7-day period. We adjusted our analysis for age, gender, race/ethnicity, educational attainment, and body mass index. Participants who reported increasing physical activity to control blood cholesterol had more PAQ-assessed physical activity and more accelerometer-assessed active days per week compared to those who did not. However, there were no significant differences in cholesterol levels between comparison groups. These findings suggest that self-report of exercising

  2. [Support of the nursing process through electronic nursing documentation systems (UEPD) – Initial validation of an instrument].

    Science.gov (United States)

    Hediger, Hannele; Müller-Staub, Maria; Petry, Heidi

    2016-01-01

    Electronic nursing documentation systems, with standardized nursing terminology, are IT-based systems for recording the nursing processes. These systems have the potential to improve the documentation of the nursing process and to support nurses in care delivery. This article describes the development and initial validation of an instrument (known by its German acronym UEPD) to measure the subjectively-perceived benefits of an electronic nursing documentation system in care delivery. The validity of the UEPD was examined by means of an evaluation study carried out in an acute care hospital (n = 94 nurses) in German-speaking Switzerland. Construct validity was analyzed by principal components analysis. Initial references of validity of the UEPD could be verified. The analysis showed a stable four factor model (FS = 0.89) scoring in 25 items. All factors loaded ≥ 0.50 and the scales demonstrated high internal consistency (Cronbach's α = 0.73 – 0.90). Principal component analysis revealed four dimensions of support: establishing nursing diagnosis and goals; recording a case history/an assessment and documenting the nursing process; implementation and evaluation as well as information exchange. Further testing with larger control samples and with different electronic documentation systems are needed. Another potential direction would be to employ the UEPD in a comparison of various electronic documentation systems.

  3. Use of electronic computers for processing of spectrometric data in instrument neutron activation analysis

    International Nuclear Information System (INIS)

    Vyropaev, V.Ya.; Zlokazov, V.B.; Kul'kina, L.I.; Maslov, O.D.; Fefilov, B.V.

    1977-01-01

    A computer program is described for processing gamma spectra in the instrumental activation analysis of multicomponent objects. Structural diagrams of various variants of connection with the computer are presented. The possibility of using a mini-computer as an analyser and for preliminary processing of gamma spectra is considered

  4. The use of instrumental neutron activation analysis for the determination of arsenic concentrations in poultry

    International Nuclear Information System (INIS)

    Bolton, B.A.; Hopke, Ph.K.

    1975-01-01

    There has been recent public concern over the use of organic arsenicals as medicaments and growth stimulators for poultry. In early studies, there was a correlation shown between the intake of arsenic and carcinogenisis. Several investigators have stronly disputed these results. The purpose of this study was not to verify or discredit this carcinogenic theory but simply to determine if the arsenic levels in poultry could be measured using instrumental activation analysis. These analyses indicate that arsenic concentrations in poultry can be measured at levels below the mandatory maximum levels of arsenic in poultry, in the investigated cases it varied between 0.3 and 0.03 ppm. Nondestructive, instrumental neutron activation analysis with a simple comparative evaluation was used: arsenic concentrations were determined by comparing the sample gamma-ray peak area to the standard peak area. (T.G.)

  5. Has the Alberta daily physical activity initiative been successfully implemented in Calgary schools?

    NARCIS (Netherlands)

    Kennedy, Christine Diane; Cantell, Marja; Dewey, Deborah

    INTRODUCTION: In September 2005, the Alberta government introduced the daily physical activity (DPA) initiative, which requires that students from grades 1 to 9 be physically active in school for a minimum of 30 min per day. OBJECTIVE: To obtain information on whether and how the DPA initiative has

  6. Determination of toxic elements in tobacco products by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Ahmad, S.; Chaudhry, M.S.; Qureshi, I.H.

    1979-01-01

    The concentration of 15 elements in various brands of cigarette tobacco and cigarette wrapping paper were determined using instrumental neutron activation analysis. The paper of some of the brands contains higher concentrations of toxic elements than the tobacco. The cigarette filter and the ash were also analyzed to determine the adsorption of toxic elements on the filter and their transference in smoke. The toxic effects of some of the elements have been briefly discussed. (author)

  7. Multielement analysis of Nigerian chewing sticks by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Asubiojo, O.I.; Guinn, V.P. (California Univ., Irvine (USA). Dept. of Chemistry); Okunuga, A. (California Polytechnic Univ., Pomona, CA (USA))

    1982-01-01

    In Nigeria, various parts of various species of native plants have long been used for dental hygiene, with reportedly considerable effectiveness. These materials are known as 'chewing sticks'. This study was an effort to ascertain whether any unusual trace element concentrations might be present in Nigerian chewing sticks. Results are presented for 17 elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Mn, Fe, Co, Zn, Br, Cs, La, Sm, Au) detected and measured in 12 species of such plants, via instrumental thermal-neutron activation analysis.

  8. Instrumental neutron activation analysis for the certification of biological reference materials

    International Nuclear Information System (INIS)

    Ambulkar, M.N.; Chutke, N.L.; Garg, A.N.

    1992-01-01

    A multielemental instrumental neutron activation analysis (INAA) method by short and long irradiation has been employed for the determination of 22 minor and trace constituents in two proposed Standard Reference Materials P-RBF and P-WBF from Institute of Radioecology and Applied Nuclear Techniques, Czechoslovakia. Also some biological standards such as Bowen's Kale, Cabbage leaves (Poland) including wheat and rice flour samples of local origin were analysed. It is suggested that INAA is an ideal method for the certification of reference materials of biological matrices. (author). 7 refs., 1 tab

  9. The U.S./IAEA Workshop on Software Sustainability for Safeguards Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Pepper S. E.; .; Worrall, L.; Pickett, C.; Bachner, K.; Queirolo, A.

    2014-08-08

    The U.S. National Nuclear Security Administration’s Next Generation Safeguards Initiative, the U.S. Department of State, and the International Atomic Energy Agency (IAEA) organized a a workshop on the subject of ”Software Sustainability for Safeguards Instrumentation.” The workshop was held at the Vienna International Centre in Vienna, Austria, May 6-8, 2014. The workshop participants included software and hardware experts from national laboratories, industry, government, and IAEA member states who were specially selected by the workshop organizers based on their experience with software that is developed for the control and operation of safeguards instrumentation. The workshop included presentations, to orient the participants to the IAEA Department of Safeguards software activities related to instrumentation data collection and processing, and case studies that were designed to inspire discussion of software development, use, maintenance, and upgrades in breakout sessions and to result in recommendations for effective software practices and management. This report summarizes the results of the workshop.

  10. Investigating the Impact of Formal Reflective Activities on Skill Adaptation in a Work-Related Instrumental Learning Setting

    Science.gov (United States)

    Roessger, Kevin M.

    2013-01-01

    In work-related, instrumental learning contexts the role of reflective activities is unclear. Kolb's (1985) experiential learning theory and Mezirow's transformative learning theory (2000) predict skill-adaptation as a possible outcome. This prediction was experimentally explored by manipulating reflective activities and assessing participants'…

  11. MODELLING THE FUTURE MUSIC TEACHERS’ READINESS TO PERFORMING AND INTERPRETIVE ACTIVITY DURING INSTRUMENTAL TRAINING

    Directory of Open Access Journals (Sweden)

    Chenj Bo

    2016-11-01

    Full Text Available One of the main fields of training future music teachers in Ukrainian system of higher education is instrumental music one, such as skills of performing and interpretive activities. The aim of the article is to design a model of the future music teachers’ readiness to performing and interpretive activities in musical and instrumental training. The process of modelling is based on several interrelated scientific approaches, including systemic, personality-centered, reflective, competence, active and creative ones. While designing a model of music future teachers’ readinesses to musical interpretive activities, its philosophical, informative, interactive, hedonistic, creative functions are taken into account. Important theoretical and methodological factors are thought to be principles of musical and pedagogical education: culture correspondence and reflection; unity of emotional and conscious, artistic and technical items in musical education; purposeful interrelations and art and pedagogical communication between teachers and students; intensification of music and creative activity. Above-mentioned pedagogical phenomenon is subdivided into four components: motivation-oriented, cognitive-evaluating, performance-independent, creative and productive. For each component relevant criteria and indicators are identified. The stages of future music teachers’ readiness to performing interpretative activity are highlighted: information searching one, which contributes to the implementation of complex diagnostic methods (surveys, questionnaires, testing; regulative and performing one, which is characterized by future music teachers’ immersion into music performing and interpretative activities; operational and reflective stage, which involves activation of mechanisms of future music teachers’ self-knowledge, self-realization, formation of skills of independent artistic and expressive various music genres and styles interpretation; projective and

  12. Study of impurity composition of some compounds of refractory metals by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Kaganov, L.K.; Dzhumakulov, D.T.; Mukhamedshina, N.M.

    1994-01-01

    The compounds of refractory transition metals find wide application in all fields of engineering, in particular in microelectronics to manufacture contact-barrier layers of thin-film current-conducting systems of silicon instruments, large and very large scale integrated circuits. Production of such materials is realted with the need to apply the analytical control methods that allow to determine a large number of elements with high reliability. The instrumental neutron-activation techniques have been developed to determine impurity composition of the following compounds: MoSi 2 , WSi 2 , TiB 2 , NbB 2 , TiC, NbC

  13. Instrumental neutron activation analysis in environmental research

    International Nuclear Information System (INIS)

    Bruin, M. de.

    1985-01-01

    The main characteristics of instrumental neutron activation analysis (INAA),relevant for environmental research and monitoring, was reviewed and discussed-sensitivity, suitable for detection of many toxic elements, the low risks of contamination of element loss, lack of matrix effects, lack of light element interference except for 24 Na, capability for multi-element determination, comparatively low costs. A detailed description of the IRI analysis system for routine INAA is given. The system is based on the single comparator method of standartization to take full advantage of multi-element without preparation and use the trace element standards. Zinc was used as mono element standard, the element concentrations are calculated on the basis of 65 Zn and 69m Zn-activities. The irradiations were carried out in a thermal neutron flux of 1.10 13 n/cm 2 .s. The gamma spectra is converted into element concentrations using a set of dedicated software, performing the following functions: spectrum analysis and interpretation, comparison and combination of the intermediate results from different decay times, generation of the final report, bookkeeping of the results obtained. The main applications of the INAA system mentioned are: identification of sources of heavy metal air pollution using air filters or biological indicators such as mosses, lichens, toe-nails, bird feathers, molusks and waterplants; and study of the uptake and translocation of heavy element in plants. Special attention was paid to mathematical techniques for a reliable interpretation of the element concentration patterns observed in sets of lichen samples. Future developments in INAA in environmental science are briefly mentioned

  14. Rio de Janeiro: Instrumentation school

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    Students from Latin America were able to get hands-on experience in state-of-the-art physics instrumentation in this year's School on Instrumentation for High Energy Physics organized by the active Instrumentation Panel of ICFA (the International Committee for Future Accelerators) at the Centro Brasileiro de Pesquicas Fisicas (CBPF), Rio de Janeiro, in July

  15. Instrumental neutron activation analysis of phosphorus in biological materials by Bremsstrahlung measurement

    International Nuclear Information System (INIS)

    Bajo, S.; Wyttenbach, A.

    1986-12-01

    The determination of phosphorus in biological materials by instrumental neutron activation via the reaction 31 P (n,γ) 32 P is described. The Bremsstrahlung produced by 32 P is measured in a well-type NaI(Tl) detector. The samples are measured within the polyethylene irradiation container with no changes between irradiation and measurement. The sources of error were studied and the proposed method was applied to the determination of phosphorus in ten internationally certified materials. (author)

  16. Online communication predicts Belgian adolescents’ initiation of romantic and sexual activity

    NARCIS (Netherlands)

    Vandenbosch, L.; Beyens, I.; Vangeel, L.; Eggermont, S.

    2016-01-01

    Online communication is associated with offline romantic and sexual activity among college students. Yet, it is unknown whether online communication is associated with the initiation of romantic and sexual activity among adolescents. This two-wave panel study investigated whether chatting, visiting

  17. Characterization of inorganic compounds in nutritional supplements by the instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Nardi, Daniela T.; Saiki, Mitiko; Vasconcellos, Maria B.A.

    2000-01-01

    In this work instrumental neutron activation analysis was applied in the analyses of samples of nutritional supplements in order to evaluate the composition of their essential inorganic components. Results obtained in these analyses presented, in general, a good agreement with the label values. Precision and accuracy of the results were also evaluated by analyzing NIST 2704 Buffalo River Sediment and NIST 1400 Bone Ash reference materials. (author)

  18. Sampling and instrumentation requirements for long-range D and D activities at INEL

    International Nuclear Information System (INIS)

    Ahlquist, A.J.

    1985-01-01

    Assistance was requested to help determine sampling and instrumentation requirements for the long-range decontamination and decommissioning activities at the Idaho National Engineering Laboratory. Through a combination of literature review, visits to other DOE contractors, and a determination of the needs for the INEL program, a draft report has been prepared that is now under review. The final report should be completed in FY 84

  19. Tool – Material, Metaphor – Metonymy, Instrument(ness)

    DEFF Research Database (Denmark)

    Bertelsen, Olav Wedege; Breinbjerg, Morten; Pold, Søren

    2008-01-01

    creativity , supported by analysis of, and interviews with, musical composers. Instrumentness is explained through discussions of materiality and metonymy as central strategies for computer mediated creativity. The paper is contributing to an investigation of the aesthetics of use in relation to software...... are controlled and conceptualized through values such as virtuosity and palyability, which are important for computer-mediated creative work supporting development in use beyond what is initially designed for. The papet performs a conceptual investigation into qualities in software interfaces that support...

  20. The dream: a psychodynamically informative instrument.

    Science.gov (United States)

    Glucksman, M L

    2001-01-01

    The dream is a unique psychodynamically informative instrument for evaluating the subjective correlates of brain activity during REM sleep. These include feelings, percepts, memories, wishes, fantasies, impulses, conflicts, and defenses, as well as images of self and others. Dream analysis can be used in a variety of clinical settings to assist in diagnostic assessment, psychodynamic formulation, evaluation of clinical change, and the management of medically ill patients. Dreams may serve as the initial indicators of transference, resistance, impending crisis, acting-out, conflict resolution, and decision-making. A clinically functional categorization of dreams can facilitate an understanding of psychopathology, psychodynamics, personality structure, and various components of the psychotherapeutic process. Examples of different types of dreams are provided to illustrate their relevance and use in various clinical situations.

  1. Determination of trace elements in fisheries samples by instrumental neutron and photon activation analysis

    International Nuclear Information System (INIS)

    Chattopadhyay, A.; Ellis, K.M.; Nimalasiri Desilva, K.

    1979-01-01

    An instrumental neutron activation analysis (INAA) method has been developed for the simultaneous determination of trace concentrations of up to 23 elements in fisheries samples. The INAA method consists of irradiations of wet and lyophilized cod muscle and liver samples for three different periods at a flux density of 5x10 11 n.cm -2 .s -1 and subsequent measurements after four different decay periods using high-resolution Ge(Li) gamma-ray spectrometry. Concentrations of several essential and toxic elements have been determined. Loss of certain elements during lyophilization has been studied. Elemental distribution in muscles and livers as a function of the age of fish has been investigated. Precision and accuracy of the INAA method have been evaluated by analysing replicate samples, National Bureau of Standards' bovine liver standard reference material, and an intercalibration fish flour sample provided by the International Council for the Exploration of the Sea. A few fish samples have also been analysed by an alternative method, namely instrumental photon activation analysis (IPAA). Elemental concentrations determined by both INAA and IPAA methods are reported here. (author)

  2. Determination of phosphorus in wheat grass samples by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Kulkarni, S.D.; Rajurkar, N.S.; Acharya, R.; Nair, A.G.C.; Reddy, A.V.R.

    2005-01-01

    An instrumental neutron activation analysis (INAA) method using β-counting was used to determine phosphorus in wheat grass; grown in three different conditions. The phosphorus concentration was found to be in the range of 950-23000 mg/g in the samples grown in different conditions. The accuracy of the method was evaluated by determining phosphorus in three reference materials and the % deviations were within 10%. Reliability of the method was checked by following the half-life of the 32 P. (author)

  3. Instrument uncertainty predictions

    International Nuclear Information System (INIS)

    Coutts, D.A.

    1991-07-01

    The accuracy of measurements and correlations should normally be provided for most experimental activities. The uncertainty is a measure of the accuracy of a stated value or equation. The uncertainty term reflects a combination of instrument errors, modeling limitations, and phenomena understanding deficiencies. This report provides several methodologies to estimate an instrument's uncertainty when used in experimental work. Methods are shown to predict both the pretest and post-test uncertainty

  4. Instrumental neutron-activation determination of impurities in lead and titanium compounds

    Energy Technology Data Exchange (ETDEWEB)

    Popova, I L

    1980-01-01

    Instrumental neutron-activation analysis was used to determine 22 impurities in lead and titanium compounds (e.g. PbO, Pb/NO3/2, and TiO2) used as raw materials for ferroelectrics. Five elements (Al, V, Mn, Sc, and Se) were determined by short-lived isotopes and 17 elements were determined by long-lived isotopes. The detection limits were 7 x 10 to the -3rd to 2 x 10 to the -8th %. A substantial difference in concentrations of certain impurity elements has been found in different series of lead and titanium oxides of similar purity.

  5. Neutron activation analysis as applied to instrumental analysis of trace elements from seawater

    International Nuclear Information System (INIS)

    Boniforti, R.; Moauro, A.; Madaro, M.

    1983-01-01

    Particulate matter collected from the coastal area delimited by the mouth of the river Volturno and the Sabaudia lake has been analyzed by instrumental neutron activation analysis for its content of twenty-two trace elements. The results for surface water and bottom water are reported separately, thus evidencing the effect of sampling depth on the concentration of many elements. The necessity of accurately 'cleaning' the filters before use is stressed

  6. Initiatives for proliferation prevention

    International Nuclear Information System (INIS)

    1997-04-01

    Preventing the proliferation of weapons of mass destruction is a central part of US national security policy. A principal instrument of the Department of Energy's (DOE's) program for securing weapons of mass destruction technology and expertise and removing incentives for scientists, engineers and technicians in the newly independent states (NIS) of the former Soviet Union to go to rogue countries or assist terrorist groups is the Initiatives for Proliferation Prevention (IPP). IPP was initiated pursuant to the 1994 Foreign Operations Appropriations Act. IPP is a nonproliferation program with a commercialization strategy. IPP seeks to enhance US national security and to achieve nonproliferation objectives by engaging scientists, engineers and technicians from former NIS weapons institutes; redirecting their activities in cooperatively-developed, commercially viable non-weapons related projects. These projects lead to commercial and economic benefits for both the NIS and the US IPP projects are funded in Russian, Ukraine, Kazakhstan and Belarus. This booklet offers an overview of the IPP program as well as a sampling of some of the projects which are currently underway

  7. Instrumentation for Nuclear Applications

    International Nuclear Information System (INIS)

    1998-01-01

    The objective of this project was to develop and coordinate nuclear instrumentation standards with resulting economies for the nuclear and radiation fields. There was particular emphasis on coordination and management of the Nuclear Instrument Module (NIM) System, U.S. activity involving the CAMAC international standard dataway system, the FASTBUS modular high-speed data acquisition and control system and processing and management of national nuclear instrumentation and detector standards, as well as a modest amount of assistance and consultation services to the Pollutant Characterization and Safety Research Division of the Office of Health and Environmental Research. The principal accomplishments were the development and maintenance of the NIM instrumentation system that is the predominant instrumentation system in the nuclear and radiation fields worldwide, the CAMAC digital interface system in coordination with the ESONE Committee of European Laboratories, the FASTBUS high-speed system and numerous national and international nuclear instrumentation standards

  8. The Insect Neuropeptide PTTH Activates Receptor Tyrosine Kinase Torso to Initiate Metamorphosis

    DEFF Research Database (Denmark)

    Rewitz, Kim; Yamanaka, Naoki; Gilbert, Lawrence

    2009-01-01

    Holometabolous insects undergo complete metamorphosis to become sexually mature adults. Metamorphosis is initiated by brain-derived prothoracicotropic hormone (PTTH), which stimulates the production of the molting hormone ecdysone via an incompletely defined signaling pathway. Here we demonstrate...... in the prothoracic gland (PG), and its loss phenocopies the removal of PTTH. The activation of Torso by PTTH stimulates extracellular signal–regulated kinase (ERK) phosphorylation, and the loss of ERK in the PG phenocopies the loss of PTTH and Torso. We conclude that PTTH initiates metamorphosis by activation...

  9. Determination of catalyst residues in hydrocarbon fuels by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Burgess, D.D.

    1982-01-01

    A procedure has been developed for the determination of entrained catalytic cracking catalyst in hydrocarbon fuels. Aluminium is measured by instrumental neutron activation analysis and the amount of catalyst present is calculated from the amount of aluminium found and the known composition of the catalyst. Entrained catalyst may be determined at levels above 3 ppm with a precision of +-2%-25% according to sample composition. Only simple procedures are required. Vanadium may reduce sensitivity by dead time and pulse pile-up. No other interferences were observed. (author)

  10. Smart antennas for nuclear instruments

    International Nuclear Information System (INIS)

    Jain, Ranjan Bala; Singhi, B.M.

    2005-01-01

    The advances in the field of computer and communications are leading to the development of smart embedded nuclear instruments. These instruments have highly sophisticated signal-processing algorithms based on FPGA and ASICS, provisions of present day connectivity and user interfaces. The developments in the connectivity, standards and bus technologies have made possible to access these instruments on LAN and WAN with suitable reliability and security. To get rid of wires i.e. in order to access these instruments, without wires at any place, wireless technology has evolved and become integral part of day-to-day activities. The environment monitoring can be done remotely, if smart antennas are incorporated on these instruments

  11. Quality control of nuclear medicine instruments

    International Nuclear Information System (INIS)

    1984-11-01

    This document, which gives detailed guidance on the quality control of the various electronic instruments used for radiation detection and measurement in nuclear medicine, stems from the work of two Advisory Groups convened by the International Atomic Energy Agency (IAEA). A preliminary document, including recommended test schedules but lacking actual protocols for the tests, was drawn up by the first of these groups, meeting at the IAEA Headquarters in Vienna in 1979. A revised and extended version, incorporating recommended test protocols, was prepared by the second Group, meeting likewise in Vienna in 1982. This version is the model for the present text. The document should be of value to all nuclear medicine units, and especially to those in developing countries, in the initiation or revision of schemes for the quality control of their instruments. Its recommendations have provided the basis for instruction in two IAEA regional technical co-operation projects in the subject field, one initiated in 1981 for countries of Latin America and one initiated in 1982 for countries of Asia and the Pacific

  12. Direct concurrent comparison of multiple pediatric acute asthma scoring instruments.

    Science.gov (United States)

    Johnson, Michael D; Nkoy, Flory L; Sheng, Xiaoming; Greene, Tom; Stone, Bryan L; Garvin, Jennifer

    2017-09-01

    Appropriate delivery of Emergency Department (ED) treatment to children with acute asthma requires clinician assessment of acute asthma severity. Various clinical scoring instruments exist to standardize assessment of acute asthma severity in the ED, but their selection remains arbitrary due to few published direct comparisons of their properties. Our objective was to test the feasibility of directly comparing properties of multiple scoring instruments in a pediatric ED. Using a novel approach supported by a composite data collection form, clinicians categorized elements of five scoring instruments before and after initial treatment for 48 patients 2-18 years of age with acute asthma seen at the ED of a tertiary care pediatric hospital ED from August to December 2014. Scoring instruments were compared for inter-rater reliability between clinician types and their ability to predict hospitalization. Inter-rater reliability between clinician types was not different between instruments at any point and was lower (weighted kappa range 0.21-0.55) than values reported elsewhere. Predictive ability of most instruments for hospitalization was higher after treatment than before treatment (p < 0.05) and may vary between instruments after treatment (p = 0.054). We demonstrate the feasibility of comparing multiple clinical scoring instruments simultaneously in ED clinical practice. Scoring instruments had higher predictive ability for hospitalization after treatment than before treatment and may differ in their predictive ability after initial treatment. Definitive conclusions about the best instrument or meaningful comparison between instruments will require a study with a larger sample size.

  13. Work station learning activities: a flexible and scalable instrument for integrating across basic subjects in biomedical education.

    Science.gov (United States)

    González-Soltero, Rocío; Learte, Ana Isabel R; Sánchez, Ana Mª; Gal, Beatriz

    2017-11-29

    Establishing innovative teaching programs in biomedical education involves dealing with several national and supra-national (i.e. European) regulations as well as with new pedagogical and demographic demands. We aimed to develop and validate a suitable instrument to integrate activities across preclinical years in all Health Science Degrees while meeting requirements of national quality agencies. The new approach was conceived at two different levels: first, we identified potentially integrative units from different fields according to national learning goals established for each preclinical year (national quality agency regulations). Secondly, we implemented a new instrument that combines active methodologies in Work Station Learning Activities (WSLA), using clinical scenarios as a guiding common thread to instruct students from an integrated perspective. We evaluated students' perception through a Likert-type survey of a total of 118 students enrolled in the first year of the Bachelor's Degree in Medicine. Our model of integrated activities through WSLA is feasible, scalable and manageable with large groups of students and a minimum number of instructors, two major limitations in many medical schools. Students' perception of WSLA was positive in overall terms. Seventy nine percent of participants stated that WSLA sessions were more useful than non-integrated activities. Eighty three percent confirmed that the WSLA methodology was effective at integrating concepts covered by different subjects. The WSLA approach is a flexible and scalable instrument for moving towards integrated curricula, and it can be successfully adapted to teach basic subjects in preclinical years of Health Science degrees. WSLA can be applied to large groups of students in a variety of contexts or environments using clinical cases as connecting threads.

  14. NASA Instrument Cost/Schedule Model

    Science.gov (United States)

    Habib-Agahi, Hamid; Mrozinski, Joe; Fox, George

    2011-01-01

    NASA's Office of Independent Program and Cost Evaluation (IPCE) has established a number of initiatives to improve its cost and schedule estimating capabilities. 12One of these initiatives has resulted in the JPL developed NASA Instrument Cost Model. NICM is a cost and schedule estimator that contains: A system level cost estimation tool; a subsystem level cost estimation tool; a database of cost and technical parameters of over 140 previously flown remote sensing and in-situ instruments; a schedule estimator; a set of rules to estimate cost and schedule by life cycle phases (B/C/D); and a novel tool for developing joint probability distributions for cost and schedule risk (Joint Confidence Level (JCL)). This paper describes the development and use of NICM, including the data normalization processes, data mining methods (cluster analysis, principal components analysis, regression analysis and bootstrap cross validation), the estimating equations themselves and a demonstration of the NICM tool suite.

  15. Active instruments

    DEFF Research Database (Denmark)

    Lim, Miguel Antonio; Ørberg, Jakob Williams

    2017-01-01

    themselves. We draw on two multi-year field studies of India and Denmark to investigate how national reforms and developments within the ranking industry interact in often surprising ways. Rankings do not always do what policy makers expect. We (1) highlight the activity of rankers in these two countries, (2...

  16. Ontogenic timing mechanism initiates the expression of rat intestinal sucrase activity

    International Nuclear Information System (INIS)

    Yeh, K.Y.; Holt, P.R.

    1986-01-01

    Morphologic and enzymic differentiation occurs in rat small intestinal epithelium during 16-20 days of postnatal life. This change is considered to be initiated by an ontogenic timing mechanism and is modulated by extrinsic systemic and luminal factors. The importance of the ontogenic timing was tested directly using a transplantation technique in which jejunal isografts from newborn (day 0) and 5-day-old (day 5) rats were implanted under the skin of newborn (day 0) hosts. Isografts showing cryptvillus architecture were obtained in 44% and 21% of transplants, respectively. Day 0 isografts and host intestine expressed sucrase activity at about 16-18 days of age and showed similar crypt cell labeling and epithelial migration after [3H]thymidine injection. Day 5 isografts expressed sucrase activity when the hosts were 13 days of age, whereas host intestine showed no detectable sucrase activity. Isograft lactase activities in both experimental transplant models were significantly higher than host intestinal lactase up to 28 days of age, suggesting that luminal factors are important in modulating lactase activity during the first 4 wk of postnatal life. It is concluded that (a) no systemic factors at day 13 inhibit the expression of sucrase activity and (b) an ontogenic timing mechanism in the jejunum initiates the expression of sucrase activity

  17. Macrophage Activation Syndrome as Initial Presentation of Systemic Lupus Erythematosus

    Directory of Open Access Journals (Sweden)

    Say-Tin Yeap

    2008-04-01

    Full Text Available Macrophage activation syndrome (MAS is known to be a severe and potentially life-threatening complication of rheumatic disorder, especially systemic juvenile rheumatoid arthritis. It is very rare for MAS to be an initial presentation of systemic lupus erythematosus (SLE. Here, we report a 14-year-old girl in whom MAS developed as an initial presentation of SLE. With early diagnosis and administration of cyclosporine A, she had a fair outcome. Further testing showed positive anti-dsDNA about 8 months later.

  18. Radiation protection commissioning of neutron beam instruments at the OPAL research reactor

    International Nuclear Information System (INIS)

    Parkes, Alison; Saratsopoulos, John; Deura, Michael; Kenny, Pat

    2008-01-01

    The neutron beam facilities at the 20 MW OPAL Research Reactor were commissioned in 2007 and 2008. The initial suite of eight neutron beam instruments on two thermal neutron guides, two cold neutron guides and one thermal beam port located at the reactor face, together with their associated shielding were progressively installed and commissioned according to their individual project plans. Radiation surveys were systematically conducted as reactor power was raised in a step-wise manner to 20 MW in order to validate instrument shielding design and performance. The performance of each neutron guide was assessed by neutron energy spectrum and flux measurements. The activation of beam line components, decay times assessments and access procedures for Bragg Institute beam instrument scientists were established. The multiple configurations for each instrument and the influence of operating more than one instrument or beamline simultaneously were also tested. Areas of interest were the shielding around the secondary shutters, guide shield and bunker shield interfaces and monochromator doors. The shielding performance, safety interlock checks, improvements, radiation exposures and related radiation protection challenges are discussed. This paper discusses the health physics experience of commissioning the OPAL Research Reactor neutron beam facilities and describes health physics results, actions taken and lessons learned during commissioning. (author)

  19. Some emergency instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Burgess, P H

    1986-10-01

    The widespread release of activity and the resultant spread of contamination after the Chernobyl accident resulted in requests to NRPB to provide instruments for, and expertise in, the measurement of radiation. The most common request was for advice on the usefulness of existing instruments, but Board staff were also involved in their adaptation or in the development of new instruments specially to meet the circumstances of the accident. The accident occurred on 26 April. On 1 May, NRPB was involved at Heathrow Airport in the monitoring of the British students who had returned from Kiev and Minsk. The main purpose was to reassure the students by checking that their persons and belongings did not have significant surface contamination. Additional measurements were also made of iodine activity in thyroid using hand-held detectors or a mobile body monitor. This operation was arranged with the Foreign and Commonwealth Office, which had also received numerous requests for instruments from embassies and consulates in countries close to the scene of the accident. There was concern for the well-being of staff and other United Kingdom nationals who resided in or intended to visit the most affected countries. The board supplied suitable instruments, and the FCO distributed them to embassies. The frequency of environmental monitoring was increased from 29 April in anticipation of contamination and appropriate Board instrumentation was deployed. After the Chernobyl cloud arrived in the UK on 2 May, there were numerous requests from local government, public authorities, private companies and members of the public for information and advice on monitoring equipment and procedures. Some of these requirements could be met with existing equipment but members of the public were usually advised not to proceed. At a later stage, the contamination of foodstuffs and livestock required the development of an instrument capable of detecting low levels of {sup 137}Cs and {sup 134}Cs in food

  20. Dopamine efflux in the nucleus accumbens during within-session extinction, outcome-dependent, and habit-based instrumental responding for food reward.

    Science.gov (United States)

    Ahn, Soyon; Phillips, Anthony G

    2007-04-01

    Dopamine (DA) activity in the nucleus accumbens (NAc) is related to the general motivational effects of rewarding stimuli. Dickinson and colleagues have shown that initial acquisition of instrumental responding reflects action-outcome relationships based on instrumental incentive learning, which establishes the value of an outcome. Given that the sensitivity of responding to outcome devaluation is not affected by NAc lesions, it is unlikely that incentive learning during the action-outcome phase is mediated by DA activity in the NAc. DA efflux in the NAc after limited and extended training was compared on the assumption that comparable changes would be observed during both action-outcome- and habit-based phases of instrumental responding for food. This study also tested the hypothesis that increase in NAc DA activity is correlated with instrumental responding during extinction maintained by a conditioned stimulus paired with food. Rats were trained to lever press for food (random-interval 30 s schedule). On the 5th and 16th day of training, microdialysis samples were collected from the NAc or mediodorsal striatum (a control site for generalized activity) during instrumental responding in extinction and then for food reward, and analyzed for DA content using high performance liquid chromatography. Increase in DA efflux in the NAc accompanied responding for food pellets on both days 5 and 16, with the magnitude of increase significantly enhanced on day 16. DA efflux was also significantly elevated during responding in extinction only on day 16. These results support a role for NAc DA activity in Pavlovian, but not instrumental, incentive learning.

  1. Instrumental neutron activities analysis of Marrubium vulgare L., a valuable medicinal herb

    Energy Technology Data Exchange (ETDEWEB)

    Nedjimi, Bouzid [Djelfa Univ. (Algeria). Lab. of Exploration and Valorization of Steppe Ecosystem; Beladel, Brahim [Djelfa Univ. (Algeria). Dept. of Physics

    2016-08-01

    Twenty two chemical elements were identified by Instrumental neutron activation analysis in Marrubium vulgare (Lamiaceae) a traditional medicine plant, used indigenously in Mediterranean basin to cure several diseases. The precision of the results was assessed by analyzing the certified reference material GBW 07605 (GSV-4) Tea leaves. Results showed that K was the dominant chemical element in studied plant (4.40%). The Ca and Fe mass fractions were also relatively high. However potential toxic elements in this Lamiaceae plant were within the safety limits suggested by WHO/FAO.

  2. Elemental analysis of soil and hair sample by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Quraishi, Shamshad Begum; Moon, Jong Hwa; Kim, Sun Ha; Baek, Sung Yeoil; Kang, Sang Hoon; Lim, Jong Myoung; Cho, Hyun Je; Kim, Young Jin

    2004-03-01

    Myanmar soil sample was analyzed by using the instrumental neutron activation analysis. The elemental concentrations in the sample, altogether 34 elements, Al As, Ba, Ce, Co, Cr, Cs, Eu, Fe, Ga, Gd, Hf, Ir, K, La, Lu, Mn, Na, Nd, Rb, Sb, Sc, Se, Sm, Th, Ti, V, Yb, Zn and Zr were determined. The concentration of 17 elements (Al, Au, Br, Ca, Cl, Cr, Cu, Co, Fe, Hg, K, Na, Mn, Mg, Sb, Se, Zn) in human hair samples were determined by INAA For quality control of analytical method, certified reference material was used

  3. Elemental analysis of soil and hair sample by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yong Sam; Quraishi, Shamshad Begum; Moon, Jong Hwa; Kim, Sun Ha; Baek, Sung Yeoil; Kang, Sang Hoon; Lim, Jong Myoung; Cho, Hyun Je; Kim, Young Jin

    2004-03-01

    Myanmar soil sample was analyzed by using the instrumental neutron activation analysis. The elemental concentrations in the sample, altogether 34 elements, Al As, Ba, Ce, Co, Cr, Cs, Eu, Fe, Ga, Gd, Hf, Ir, K, La, Lu, Mn, Na, Nd, Rb, Sb, Sc, Se, Sm, Th, Ti, V, Yb, Zn and Zr were determined. The concentration of 17 elements (Al, Au, Br, Ca, Cl, Cr, Cu, Co, Fe, Hg, K, Na, Mn, Mg, Sb, Se, Zn) in human hair samples were determined by INAA For quality control of analytical method, certified reference material was used.

  4. Limits of detection in instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Guinn, V.P.

    1990-01-01

    Lower limits of detection (LLODs), frequently referred to simply as limits of detection and abbreviated as LODs, often appear in the literature of analytical chemistry - for numerous different methods of elemental and/or molecular analysis. In this chapter, one particular method of quantitative elemental analysis, that of instrumental neutron activation analysis (INAA), is the subject discussed, with reference to LODs. Particularly in the literature of neutron activation analysis (NAA), many tables of 'interference-free' NAA LODs are available. Not all of these are of much use, because (1) for many the definition used for LOD is not clear, or reasonable, (2) for many, the analysis conditions used are not clearly specified, and (3) for many, the analysis conditions used are specified, but not very practicable for most laboratories. For NAA work, such tables of interference-free LODs are, in any case, only applicable to samples in which, at the time of counting, only one radionuclide is present to any significant extent in the activated sample. It is important to note that tables of INAA LODs, per se, do not exist - since the LOD for a given element, under stated analysis conditions, can vary by orders of magnitude, depending on the elemental composition of the matrix in which it is present. For any given element, its INAA LOD will always be as large as, and usually much larger than, its tabulated 'interference-free' NAA LOD - how much larger depending upon the elemental composition of the matrix in which it is present. As discussed in this chapter, however, an INAA computer program exists that can calculate realistic INAA LODs for any elements of interest, in any kind of specified sample matrix, under any given set of analysis conditions

  5. Uses of instrumental neutron activation analysis (INAA) for lichen as bio indicators of environmental contamination

    International Nuclear Information System (INIS)

    Arribere, M.; Guevara, S.R.; Calvelo, S.

    1994-01-01

    Three species of epiphytic lichens were sampled at NW Patagonia, Argentina, from urban and peripherical forest area environments Sixty lichen samples were analysed individually by Instrumental Neutron Activation Analysis (INAA). The elements present in the samples were determined by parametric methods at the Neutron Activation Laboratory at Centro Atomico Bariloche, Argentina. All concentration values were normalized to Al concentration. The average normalized concentrations for each element, discriminated by species and environment, are presented in this work. (author). 11 refs, 6 tabs

  6. Direct instrumental identification of catalytically active surface sites

    Science.gov (United States)

    Pfisterer, Jonas H. K.; Liang, Yunchang; Schneider, Oliver; Bandarenka, Aliaksandr S.

    2017-09-01

    The activity of heterogeneous catalysts—which are involved in some 80 per cent of processes in the chemical and energy industries—is determined by the electronic structure of specific surface sites that offer optimal binding of reaction intermediates. Directly identifying and monitoring these sites during a reaction should therefore provide insight that might aid the targeted development of heterogeneous catalysts and electrocatalysts (those that participate in electrochemical reactions) for practical applications. The invention of the scanning tunnelling microscope (STM) and the electrochemical STM promised to deliver such imaging capabilities, and both have indeed contributed greatly to our atomistic understanding of heterogeneous catalysis. But although the STM has been used to probe and initiate surface reactions, and has even enabled local measurements of reactivity in some systems, it is not generally thought to be suited to the direct identification of catalytically active surface sites under reaction conditions. Here we demonstrate, however, that common STMs can readily map the catalytic activity of surfaces with high spatial resolution: we show that by monitoring relative changes in the tunnelling current noise, active sites can be distinguished in an almost quantitative fashion according to their ability to catalyse the hydrogen-evolution reaction or the oxygen-reduction reaction. These data allow us to evaluate directly the importance and relative contribution to overall catalyst activity of different defects and sites at the boundaries between two materials. With its ability to deliver such information and its ready applicability to different systems, we anticipate that our method will aid the rational design of heterogeneous catalysts.

  7. Management Approach for Earth Venture Instrument

    Science.gov (United States)

    Hope, Diane L.; Dutta, Sanghamitra

    2013-01-01

    The Earth Venture Instrument (EVI) element of the Earth Venture Program calls for developing instruments for participation on a NASA-arranged spaceflight mission of opportunity to conduct innovative, integrated, hypothesis or scientific question-driven approaches to pressing Earth system science issues. This paper discusses the EVI element and the management approach being used to manage both an instrument development activity as well as the host accommodations activity. In particular the focus will be on the approach being used for the first EVI (EVI-1) selected instrument, Tropospheric Emissions: Monitoring of Pollution (TEMPO), which will be hosted on a commercial GEO satellite and some of the challenges encountered to date and corresponding mitigations that are associated with the management structure for the TEMPO Mission and the architecture of EVI.

  8. Neutron scattering instruments for the Spallation Neutron Source (SNS)

    International Nuclear Information System (INIS)

    Crawford, R.K.; Fornek, T.; Herwig, K.W.

    1998-01-01

    The Spallation Neutron Source (SNS) is a 1 MW pulsed spallation source for neutron scattering planned for construction at Oak Ridge National Laboratory. This facility is being designed as a 5-laboratory collaboration project. This paper addresses the proposed facility layout, the process for selection and construction of neutron scattering instruments at the SNS, the initial planning done on the basis of a reference set of ten instruments, and the plans for research and development (R and D) to support construction of the first ten instruments and to establish the infrastructure to support later development and construction of additional instruments

  9. Nuclear electronic instrumentation

    International Nuclear Information System (INIS)

    Ramirez J, F. J.

    2010-01-01

    The activities carried out in the Instituto Nacional de Investigaciones Nucleares (ININ) in the field of the nuclear electronic instrumentation included those activities corresponding to the design and production of nuclear instruments in a first stage, as well as the internal activities of design, repair and maintenance that have supported to other projects of the institution during many years. It is mentioned of the presence and constant collaboration of the ININ with the IAEA in different projects and programs. Also, it is mentioned on the establishment of the Radiation Detectors Laboratory, which for their characteristics and repair capacities of radiation detectors of cooled semiconductor, it is only in their specialty. It is emphasized the investigation and the development in the field of new radiation detectors and applications, as well as the important contribution in this field, in institutions like: Mexican Petroleum, National Commission of Nuclear Safety and Safeguards and Federal Commission of Electricity. Finally a position of the future of these activities is made, considering the speed of the advances of the electronic and nuclear technology. (Author)

  10. INDUSTRIAL/MILITARY ACTIVITY-INITIATED ACCIDENT SCREENING ANALYSIS

    Energy Technology Data Exchange (ETDEWEB)

    D.A. Kalinich

    1999-09-27

    Impacts due to nearby installations and operations were determined in the Preliminary MGDS Hazards Analysis (CRWMS M&O 1996) to be potentially applicable to the proposed repository at Yucca Mountain. This determination was conservatively based on limited knowledge of the potential activities ongoing on or off the Nevada Test Site (NTS). It is intended that the Industrial/Military Activity-Initiated Accident Screening Analysis provided herein will meet the requirements of the ''Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants'' (NRC 1987) in establishing whether this external event can be screened from further consideration or must be included as a design basis event (DBE) in the development of accident scenarios for the Monitored Geologic Repository (MGR). This analysis only considers issues related to preclosure radiological safety. Issues important to waste isolation as related to impact from nearby installations will be covered in the MGR performance assessment.

  11. Absolute instrumental neutron activation analysis at Lawrence Livermore Laboratory

    International Nuclear Information System (INIS)

    Heft, R.E.

    1977-01-01

    The Environmental Science Division at Lawrence Livermore Laboratory has in use a system of absolute Instrumental Neutron Activation Analysis (INAA). Basically, absolute INAA is dependent upon the absolute measurement of the disintegration rates of the nuclides produced by neutron capture. From such disintegration rate data, the amount of the target element present in the irradiated sample is calculated by dividing the observed disintegration rate for each nuclide by the expected value for the disintegration rate per microgram of the target element that produced the nuclide. In absolute INAA, the expected value for disintegration rate per microgram is calculated from nuclear parameters and from measured values of both thermal and epithermal neutron fluxes which were present during irradiation. Absolute INAA does not depend on the concurrent irradiation of elemental standards but does depend on the values for thermal and epithermal neutron capture cross-sections for the target nuclides. A description of the analytical method is presented

  12. Alberta Learning: Early Development Instrument Pilot Project Evaluation.

    Science.gov (United States)

    Meaney, Wanda; Harris-Lorenze, Elayne

    The Early Development Instrument (EDI) was designed by McMaster University to measure the outcomes of childrens early years as they influence their readiness to learn at school. The EDI was piloted in several Canadian cities in recent years through two national initiatives. Building on these initiatives, Alberta Learning piloted the EDI as a…

  13. Instrumentation amplifier implements second-order active low-pass filter with high gain factor

    International Nuclear Information System (INIS)

    Blomqvist, Kim H; Eskelinen, Pekka; Sepponen, Raimo E

    2011-01-01

    A single-ended second-order active low-pass filter can simultaneously provide high gain factor and dc voltage subtraction. This makes it possible to reduce the number of components and signal processing stages needed in an application where small voltage changes are measured on the top of large dc voltage masked by a large amplitude oscillating carrier. The filter described in this paper is constructed from a conventional 3-op-amp instrumentation amplifier and five passive circuit elements. (technical design note)

  14. Trace elements in cigarette tobacco by a method of instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Noordin Ibrahim

    1986-01-01

    A total of ten cigarette brands were investigated for determining the trace elemental concentrations in tobacco so as to assess their role in the induction of related diseases through smoking. A method instrumental Neutron Activation analysis was employed due to high sensitivity, speed and ability to analyse sample for a wide spectrum of elements simultaneously. A total of 18 elements were detected of which the majority are toxic elements. A full result and conclusion will be reported in the forthcoming paper. (A.J.)

  15. Nondestructive assay of fluorine in geological and other materials by instrumental photon activation analysis with a microtron

    Czech Academy of Sciences Publication Activity Database

    Krausová, I.; Mizera, Jiří; Řanda, Z.; Chvátil, D.; Krist, P.

    2015-01-01

    Roč. 342, JAN (2015), s. 82-86 ISSN 0168-583X Institutional support: RVO:67985891 Keywords : fluorine * instrumental photon activation analysis * IPAA * coal Subject RIV: BG - Nuclear , Atomic and Molecular Physics, Colliders Impact factor: 1.389, year: 2015

  16. An improved instrument setpoint control program

    International Nuclear Information System (INIS)

    Cash, J.S. Jr.; George, R.T.; Kincaid, S.C.

    1991-01-01

    Instrument setpoints have a definite and often significant impact on plant safety, reliability, and availability. Although typically overshadowed by plant design, modification, and physical change activities, instrument setpoints can alter plant status and system operating characteristics just as significantly. Recognizing the need for a formal program that provides configuration control of instrument setpoints, provides a readily accessible and clearly documented basis for instrument setpoints, and integrates and coordinates operations, engineering, and maintenance activities that influence the basis for instrument setpoints, Philadelphia Electric Company (PECo) is developing an Improved Instrument Setpoint Control Program (IISCP) that incorporates current industry guidance and practices and state-of-the-art information systems technology. The IISCP was designed around PECo's then existing business processes for setpoint control, determination, and maintenance. A task force representing the various constituencies from both plants and the engineering and services organizations were formed to identify objectives and design features for the IISCP. Utilizing industry standards and guidance, regulatory documents, the experiences and good practices obtained from other utilities, and PECo's nuclear group strategies, objectives, and goals, specific objectives were identified to enhance the business processes

  17. Multielement determination in some egyptian vegetables by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Tadros, N.A.; Abdel-Fattah, A.A.; Sanad, W.A.

    1999-01-01

    Nondestructive instrumental neutron activation analysis (INAA) technique, with thermal neutrons, has been applied for multielement determination of major, trace and ultra trace elements in eleven types of the public public egyptian, edible vegetables, namely dill, moulokhyia, okra negro bean, parsley, green pea, grape leaves, spinach, mint, celery and salad chervil, cultivated and collected from El-Maadi, Cairo, E G. Concentrations of Na, K, Ca, Sc, Cr, Fe, Co, Ni, Zn, Rb, Zr, Nb, Mo, Sb, Cs, Ba, La, Ce, Tb, Yb, Hf, Ta, Th and U were determined. The standard reference materials (SRM's) G-2, J G-1 and MAG-1, provided from IAEA, were used, and high accuracy of the work was assured. The results were discussed

  18. Mastication suppresses initial gastric emptying by modulating gastric activity.

    Science.gov (United States)

    Ohmure, H; Takada, H; Nagayama, K; Sakiyama, T; Tsubouchi, H; Miyawaki, S

    2012-03-01

    Because various mastication-related factors influence gastric activity, the functional relationship between mastication and gastric function has not been fully elucidated. To investigate the influence of mastication on gastric emptying and motility, we conducted a randomized trial to compare the effects of mastication on gastric emptying and gastric myoelectrical activity under conditions that excluded the influences of food comminution, taste, and olfaction. A (13)C-acetate breath test with electrogastrography and electrocardiography was performed in 14 healthy men who ingested a test meal with or without chewing gum. Autonomic nerve activity was evaluated by fluctuation analysis of heart rate. Gastric emptying was significantly delayed in the 'ingestion with mastication' group. Gastric myoelectrical activity was significantly suppressed during mastication and increased gradually in the post-mastication phase. A decrease in the high-frequency power of heart rate variability was observed coincidentally with gastric myoelectrical activity suppression. These findings suggest that initial gastric emptying is suppressed by mastication, and that the suppression is caused by mastication-induced inhibition of gastric activity (UMIN Clinical Trial Registration no. UMIN000005351).

  19. Transaction costs of energy efficiency policy instruments

    Energy Technology Data Exchange (ETDEWEB)

    Mundaca, Luis [International Inst. for Industrial Environmental Economics, Lund Univ. (Sweden)

    2007-07-01

    This paper identifies the nature and scale of transaction costs (TCs) under different policy instruments aimed to increase energy efficiency. It analyses three cases: a) GHG-driven initiatives, b) tradable 'White Certificate' (TWC) schemes -taking the Energy Efficiency Commitment in Great Britain as a case study-, and c) energy efficiency audits given by grid companies in Denmark. The analysis focuses on TCs borne by project developers or obliged parties under these initiatives. Several sources of TCs are considered, such as search for information, persuasion of customers, negotiation with business partners, and measurement and verification (M and V) activities. Information has been obtained through a literature review, interviews with stakeholders and questionnaires. Some similarities were found as far as the nature of TCs is concerned. Relevant sources of TCs appear to be the search for information (for both potential measures and beneficiaries), negotiation and contract agreements with third parties, follow-up of measures, M and V activities and due accreditation of savings. The scale of TCs differs to a large extent, ranging from 5 % to 36 % of total audit/project costs. Figures must be taken with caution due to a number of specific factors driving their order of magnitude, including levels of uncertainty and the TCs accounting problem. Indications of economies of scale were only found for the case of GHG policy initiatives. In all, estimations are very case-specific and cannot be comparable. It is concluded that a number of endogenous and exogenous determinants affect the nature and scale of TCs for the analysed cases.

  20. Toenail elemental analysis of Korean young adults by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Lee, O.

    2016-01-01

    The element contents in toenail clippings of healthy Korean young adults were measured using an instrumental neutron activation analysis. The average contents of elements such as Na, K, Cl, Ca, Fe, Se, and Zn are 449, 474, 1024, 1677, 66, 0.7 and 94 mg/kg in men, whereas those contents in women respectively 332, 476, 836, 1097, 66, 0.8 and 104 mg/kg. The correlation analysis of toenail elements with chronic disease risks showed positive associations between Na and serum HDL-cholesterol, blood pressure, and negative associations between Se and Hs-CRP, between Zn and hemoglobin level. (author)

  1. Trace elements evaluation of some medicinal herbs by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Zaidi, J.H.; Fatima, I.; Qureshi, I.H.; Subhani, M.S.

    2004-01-01

    Instrumental neutron activation analysis has been used for the analysis of seven varieties of medicinal herbs generally used by the people of South Asian region. Twenty-one trace elements (essential, toxic and non-essential) were determined. This data should not only be helpful in establishing the base-line values in these medicinal herbs but also in correlating their role as therapeutic agents. A comparison of our data with literature values shows variation in trace element contents of same species of different origin which can be attributed to ecological and geographical variations to some extent; however an exact interpretation demands further extensive investigations. (orig.)

  2. Determination of gold and silver in geological standard samples MGI by instrument neutron activation analysis

    International Nuclear Information System (INIS)

    Lu Huijiuan; Zhou; Yunlu

    1987-01-01

    Gold and silver in geological standard samples MGI were determined by instrument neutron activation analysis. The various interferences of nuclides were considered. Corrected factors of the geometry in different positions have been determined. Using the geological standard sample MGM and radiochemical separation neutron activation method as reference, the reliability of this method is proved. Gold content in samples is 0.4-0.009 g/t, silver content is 9-0.3 g/t. Standard deviation is less than 3.5%, the precision of the measurement is 4.8-11.6%

  3. Weather Instruments.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities to measure various weather phenomena. Directions for constructing a weather station are included. Instruments including rain gauges, thermometers, wind vanes, wind speed devices, humidity devices, barometers, atmospheric observations, a dustfall jar, sticky-tape can, detection of gases in the air, and pH of…

  4. Role of the σ54 Activator Interacting Domain in Bacterial Transcription Initiation

    Energy Technology Data Exchange (ETDEWEB)

    Siegel, Alexander R. [Univ. of California, Berkeley, CA (United States); Wemmer, David E. [Univ. of California, Berkeley, CA (United States)

    2016-10-11

    Bacterial sigma factors are subunits of RNA polymerase that direct the holoenzyme to specific sets of promoters in the genome and are a central element of regulating transcription. Most polymerase holoenzymes open the promoter and initiate transcription rapidly after binding. However, polymerase containing the members of the σ54 family must be acted on by a transcriptional activator before DNA opening and initiation occur. A key domain in these transcriptional activators forms a hexameric AAA + ATPase that acts through conformational changes brought on by ATP hydrolysis. Contacts between the transcriptional activator and σ54 are primarily made through an N-terminal σ54 activator interacting domain (AID). To better understand this mechanism of bacterial transcription initiation, we characterized the σ54 AID by NMR spectroscopy and other biophysical methods and show that it is an intrinsically disordered domain in σ54 alone. In this paper, we identified a minimal construct of the Aquifex aeolicus σ54 AID that consists of two predicted helices and retains native-like binding affinity for the transcriptional activator NtrC1. Using the NtrC1 ATPase domain, bound with the non-hydrolyzable ATP analog ADP-beryllium fluoride, we studied the NtrC1–σ54 AID complex using NMR spectroscopy. We show that the σ54 AID becomes structured after associating with the core loops of the transcriptional activators in their ATP state and that the primary site of the interaction is the first predicted helix. Finally, understanding this complex, formed as the first step toward initiation, will help unravel the mechanism of σ54 bacterial transcription initiation.

  5. Characterization of ophiolites from northern Havana-Matanzas petroleum fields using instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Montero Cabrera, M.E. E-mail: montero@yakko.cimav.edu.mx; Ortueta Milan, M.; Herrera Peraza, E.F.; Herrera Hernandez, H.; Rodriguez Martinez, N.; Olivares Rieumont, S.; Lopez Reyes, M.C

    2001-01-15

    Concentrations of 16 elements from 14 serpentinitic samples from Basilio and Cantel petroleum fields were obtained by instrumental neutron activation analysis (INAA): Cr, Co, Ni, La, Nd, Sm, Eu, Gd, Tb, Ce Yb, Lu, Rb, Cs, Hf and Th. Relative INAA was performed using certified reference materials and laboratory standards. Average elemental concentrations showed that the ophiolites have a basic character, suggesting the use of a well-logging method designed for volcano-sedimentary petroleum fields.

  6. Characterization of ophiolites from northern Havana-Matanzas petroleum fields using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Montero Cabrera, M.E.; Ortueta Milan, M.; Herrera Peraza, E.F.; Herrera Hernandez, H.; Rodriguez Martinez, N.; Olivares Rieumont, S.; Lopez Reyes, M.C.

    2001-01-01

    Concentrations of 16 elements from 14 serpentinitic samples from Basilio and Cantel petroleum fields were obtained by instrumental neutron activation analysis (INAA): Cr, Co, Ni, La, Nd, Sm, Eu, Gd, Tb, Ce Yb, Lu, Rb, Cs, Hf and Th. Relative INAA was performed using certified reference materials and laboratory standards. Average elemental concentrations showed that the ophiolites have a basic character, suggesting the use of a well-logging method designed for volcano-sedimentary petroleum fields

  7. Holdup Measures on an SRNL Mossbauer Spectroscopy Instrument

    Energy Technology Data Exchange (ETDEWEB)

    Dewberry, R.; Brown, T.; Salaymeh, S.

    2010-05-05

    Gamma-ray holdup measurements of a Mossbauer spectroscopy instrument are described and modeled. In the qualitative acquisitions obtained in a low background area of Savannah River National Laboratory, only Am-241 and Np-237 activity were observed. The Am-241 was known to be the instrumental activation source, while the Np-237 is clearly observed as a source of contamination internal to the instrument. The two sources of activity are modeled separately in two acquisition configurations using two separate modeling tools. The results agree well, demonstrating a content of (1980 {+-} 150) {mu}Ci Am-241 and (110 {+-} 50) {mu}Ci of Np-237.

  8. Air pollution assessment in two Moroccan cities using instrumental neutron activation analysis on bio-accumulators

    International Nuclear Information System (INIS)

    Embarch, K.; Moutea, Z.; Bounakhla, M.; Cherkaoui, R.; Chouak, A.; Lferde, M.; Gaudry, A.

    2008-01-01

    Full text: Biomonitoring is an appropriate tool for the air pollution assessment studies. In this work, lichens and barks have been used as bio-accumulators in several sites in two Moroccan cities (Rabat and Mohammadia). The specific ability of absorbing and accumulating heavy metals and toxic element from the air, their longevity and resistance to the environmental stresses, make those bioindicators suitable for this kind of studies. The Instrumental Neutron Activation Analysis (INAA) is universally accepted as one of the most reliable analytical tools for trace and ultra-trace elements determination. Its use in trace elements atmospheric pollution related studies has been and is still extensive as can be demonstrated by several specific works and detailed reviews. In this work, a preliminary investigation employing lichens, barks and instrumental neutron activation analysis (INAA) was carried out to evaluate the trace elements distribution in six different areas of Rabat and Mohammadia cities characterised by the presence of many industries and heavy traffic. Samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted using high-resolution Germanium-Lithium detectors. More than 30 elements were determined using two modes : short irradiation (1 minute) and long irradiation (17 hours). Accuracy and quality control were assessed using the reference standard material IAEA-336. This was less than 1% for major and about 5 to 10% for traces. [fr

  9. Seismic refraction profile, Kingdom of Saudi Arabia: field operations, instrumentation, and initial results

    Science.gov (United States)

    Blank, H. Richard; Healy, J.H.; Roller, John; Lamson, Ralph; Fisher, Fred; McClearn, Robert; Allen, Steve

    1979-01-01

    In February 1978 a seismic deep-refraction profile was recorded by the USGS along a 1000-km line across the Arabian Shield in western Saudi Arabia. The line begins in Paleozoic and Mesozoic cover rocks near Riyadh on the Arabian Platform, leads southwesterly across three major Precambrian tectonic provinces, traverses Cenozoic rocks of the coastal plain near Jizan (Tihamat Asir), and terminates at the outer edge of the Farasan Bank in the southern Red Sea. More than 500 surveyed recording sites were occupied, including 19 in the Farasan Islands. Six shot points were used--five on land, with charges placed mostly below water table in drill holes, and one at sea, with charges placed on the sea floor and fired from a ship. The total charge consumed was slightly in excess of 61 metric tons in 21 discrete firings. Seismic energy was recorded by means of a set of 100 newly developed portable seismic stations. Each station consists of a standard 2-Hz vertical geophone coupled to a self-contained analog recording instrument equipped with a magnetic-tape cassette. The stations were deployed in groups of 20 by five observer teams, each generally consisting of two scientist-technicians and a surveyor-guide. On the day prior to deployment, the instruments were calibrated and programmed for automatic operation by means of a specially designed device called a hand-held tester. At each of ten pre-selected recording time windows on a designated firing day, the instruments were programmed to turn on, stabilize, record internal calibration signals, record the seismic signals at three levels of amplification, and then deactivate. After the final window in the firing sequence, all instruments were retrieved and their data tapes removed for processing. A specially designed, field tape- dubbing system was utilized at shot point camps to organize and edit data recorded on the cassette tapes. The main functions of this system are to concatenate all data from each shot on any given day

  10. Breastfeeding Self-efficacy: A Critical Review of Available Instruments

    Science.gov (United States)

    Tuthill, Emily L.; McGrath, Jacqueline M.; Graber, Melanie; Cusson, Regina M.; Young, Sera L.

    2016-01-01

    Increasing breastfeeding rates in the United States is a national priority. Yet, initiation and duration of breastfeeding remains below national targets. Breastfeeding self-efficacy has been shown to be a strong predictor of both breastfeeding initiation and duration and is therefore an important characteristic to be able to measure. However, there is currently a myriad of instruments for measuring breastfeeding self-efficacy, which makes selection of an appropriate instrument difficult. Thus, our aim was to identify, compare, and critically review available breastfeeding self-efficacy instruments. In a systematic review, 6 breastfeeding self-efficacy instruments were identified. The instruments’ purposes, theoretical framework, final scale development, and application in 5 most recent settings were analyzed. The 6 breastfeeding self-efficacy instruments apply a number of theoretical and conceptual frameworks in their development, with Bandura’s social cognitive theory being most common. Content, construct, and predictive validity were strong for most scales. Some, but not all, have been successfully adapted to novel settings. In sum, there are several measurements of breastfeeding self-efficacy that can and should be employed to better understand reasons for suboptimal breastfeeding rates and the effects of interventions on breastfeeding self-efficacy. Instrument selection should be based on domains of primary interest, time available, peripartum timing, and assessment of previous adaptations. Failure to apply appropriate measures in research may garner results that are inconclusive, inaccurate, or nonrepresentative of true study effects. PMID:26319113

  11. Nuclear instrumentation evaluation and analysis

    International Nuclear Information System (INIS)

    Park, Suk Jun; Han, Sang Joon; Chung, Chong Eun; Han, Kwang Soo; Kim, Dong Hwa; Park, Byung Hae; Moon, Je Sun; Lee, Chel Kwon; Song, Ki Sang; Choi, Myung Jin; Kim, Seung Bok; Kim, Jung Bok

    1986-12-01

    This project provides the program for improving instrumentation reliability as well as developing a cost-effective preventive maintenance activity through evaluation and analysis of nuclear instrumentation concerning pilot plants, large-scale test facilities and various laboratories on KAERI site. In addition, it discusses the program for enhancing safe operations and improving facility availability through establishment of maintenance technology. (Author)

  12. 2H Evaporator CP class instrumentation uncertainties evaluations

    International Nuclear Information System (INIS)

    Hwang, E.

    1994-01-01

    The Evaporator Pot Temperature Instrumentations and the Steam Condensate Gamma Monitors are two instrumentation systems in the 2H Evaporator facilities that are classified as the critical protection. The temperature high alarm and interlock circuit and the temperature recorder circuit of the pot temperature instrumentation loop are described. From the gamma monitor loop, the high gamma alarm and interlock circuit, failure alarm and interlock circuit, cesium activity recorder circuit, and americium activity recorder circuit are described

  13. 2H Evaporator CP class instrumentation uncertainties evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, E.

    1994-02-10

    The Evaporator Pot Temperature Instrumentations and the Steam Condensate Gamma Monitors are two instrumentation systems in the 2H Evaporator facilities that are classified as the critical protection. The temperature high alarm and interlock circuit and the temperature recorder circuit of the pot temperature instrumentation loop are described. From the gamma monitor loop, the high gamma alarm and interlock circuit, failure alarm and interlock circuit, cesium activity recorder circuit, and americium activity recorder circuit are described. (GHH)

  14. ICFA Instrumentation Bulletin, Volume 14, Spring 1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-07-01

    The publication of the ICFA Instrumentation Bulletin is an activity of the Panel on Future Innovation and Development of ICFA (International Committee for Future Accelerators). The Bulletin reports on research and progress in the field of instrumentation with emphasis on application in the field of high-energy physics. It encourages issues of generic instrumentation.

  15. Using XML and Java for Astronomical Instrumentation Control

    Science.gov (United States)

    Ames, Troy; Koons, Lisa; Sall, Ken; Warsaw, Craig

    2000-01-01

    Traditionally, instrument command and control systems have been highly specialized, consisting mostly of custom code that is difficult to develop, maintain, and extend. Such solutions are initially very costly and are inflexible to subsequent engineering change requests, increasing software maintenance costs. Instrument description is too tightly coupled with details of implementation. NASA Goddard Space Flight Center is developing a general and highly extensible framework that applies to any kind of instrument that can be controlled by a computer. The software architecture combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML), a human readable and machine understandable way to describe structured data. A key aspect of the object-oriented architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). ]ML is used to describe graphical user interfaces to control and monitor the instrument, command sets and command formats, data streams, and communication mechanisms. Although the current effort is targeted for the High-resolution Airborne Wideband Camera, a first-light instrument of the Stratospheric Observatory for Infrared Astronomy, the framework is designed to be generic and extensible so that it can be applied to any instrument.

  16. IAEA programme on maintenance of nuclear instruments

    International Nuclear Information System (INIS)

    Vuister, P.H.

    1986-01-01

    The Medical Applications Section in the Division of Life Sciences of the International Atomic Energy Agency has been engaged since 1975 in activities aimed at the more effective use of nuclear instruments. Activities and achievements are described concerning the conditioning of laboratories, preventive maintenance and repair of instruments, the management thereof, space parts and the promotion of local training in these subjects. (author)

  17. Elementary composition of the siderurgy slag by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Oliveira, Helder de; Piau, Wilson Caixeta; Mortatti, Jefferson; Sarries, Gabriel Adrian

    2000-01-01

    The slag has been applied to the ground to neutralize its acidity, in similar way to the calcareous rock, contributing in the agriculture as corrective of the acidity alone it and source of nutrients for the plants. However, the alternative for the agricultural slag exploitation is related to metal texts heavy gifts in the slag. The objective of the present work was to survey of the chemical composition of trashes generated in blast high-oven, steel, oven of pan and fertilizers that had used in its manufacture slag of siderurgy for the technique of instrumental neutron activation analysis. The results had evidenced the existence of high variations in the elements Ce, Cr, In, K, Sb and Zn in the distinct analyzed samples. (author)

  18. Radon-Instrumentation; Radon-Instrumentacion

    Energy Technology Data Exchange (ETDEWEB)

    Moreno y Moreno, A. [Departamento de Apoyo en Ciencias Aplicadas, Benemerita Universidad Autonoma de Puebla, 4 Sur 104, Centro Historico 72000 Puebla (Mexico)

    2003-07-01

    The presentation of the active and passive methods for radon, their identification and measure, instrumentation and characteristics are the objectives of this work. Active detectors: Active Alpha Cam Continuous Air Monitor, Model 758 of Victoreen, Model CMR-510 Continuous Radon Monitor of the Signature Femto-Tech. Passive detectors: SSNTD track detectors in solids Measurement Using Charcoal Canisters, disk of activated coal deposited in a metallic box Electrets Methodology. (Author)

  19. Determinants of The Application of Macro Prudential Instruments

    Directory of Open Access Journals (Sweden)

    Zakaria Firano

    2017-09-01

    Full Text Available The use of macro prudential instruments today gives rise to a major debate within the walls of central banks and other authorities in charge of financial stability. Contrary to micro prudential instruments, whose effects remain limited, macro prudential instruments are different in nature and can affect the stability of the financial system. By influencing the financial cycle and the financial structure of financial institutions, the use of such instruments should be conducted with great vigilance as well as macroeconomic and financial expertise. But the experiences of central banks in this area are sketchy, and only some emerging countries have experience using these types of instruments in different ways. This paper presents an analysis of instruments of macro prudential policy and attempts to empirically demonstrate that these instruments should be used only in specific economic and financial situations. Indeed, the results obtained, using modeling bivariate panel, confirm that these instruments are more effective when used to mitigate the euphoria of financial and economic cycles. In this sense, the output gap, describing the economic cycle, and the Z-score are the intermediate variables for the activation of capital instruments. Moreover, the liquidity ratio and changes in bank profitability are the two early warning indicators for activation of liquidity instruments.

  20. Pyrrolizidine Alkaloids: Metabolic Activation Pathways Leading to Liver Tumor Initiation.

    Science.gov (United States)

    Fu, Peter P

    2017-01-17

    Pyrrolizidine alkaloids (PAs) and PA N-oxides are a class of phytochemical carcinogens contained in over 6000 plant species spread around the world. It has been estimated that approximately half of the 660 PAs and PA N-oxides that have been characterized are cytotoxic, genotoxic, and tumorigenic. It was recently determined that a genotoxic mechanism of liver tumor initiation mediated by PA-derived DNA adducts is a common metabolic activation pathway of a number of PAs. We proposed this set of PA-derived DNA adducts could be a common biological biomarker of PA exposure and a potential biomarker of PA-induced liver tumor formation. We have also found that several reactive secondary pyrrolic metabolites can dissociate and interconvert to other secondary pyrrolic metabolites, resulting in the formation of the same exogenous DNA adducts. This present perspective reports the current progress on these new findings and proposes future research needed for obtaining a greater understanding of the role of this activation pathway and validating the use of this set of PA-derived DNA adducts as a biological biomarker of PA-induced liver tumor initiation.

  1. Instrument-related Skin Disorders in Musicians.

    Science.gov (United States)

    Patruno, Cataldo; Napolitano, Maddalena; La Bella, Serena; Ayala, Fabio; Balato, Nicola; Cantelli, Mariateresa; Balato, Anna

    2016-01-01

    Among artists, musicians may suffer from occupational skin problems; notwithstanding, these conditions have been rarely reviewed. The characteristics of individual performer and the type of instrument will determine the kind of disease. Moreover, the hours that the musician spent to advance artistic skill may influence the severity. The frequency and risk factors of instrument-related skin disorders in musicians from southern Italy were analyzed. An observational study was conducted in 628 musicians. A questionnaire including questions related to age, sex, instrument played, musical activity, previous or current skin disorders, and impact of skin symptoms on music making was submitted. Of 628 musicians, 199 (31.7%) reported suffering from at least 1 skin disease. Cutaneous diseases likely directly correlated with the use of the musical instrument were found in 129 (20.5%) of the 628 subjects. In particular, different patterns of irritant contact dermatitis were found. Skin conditions may be a significant problem in professional instrumentalists. They are mainly related to musical activity. Preventive measures should be established.

  2. Activities in the field of nuclear reactor instrumentation and control in Poland - 1991 status

    International Nuclear Information System (INIS)

    Mikulski, A.T.

    1992-01-01

    The report gives a condensed overview of activity in the field of nuclear reactor instrumentation and control in Poland over the last few years. The work was performed parallel in two directions related to the construction of the first Nuclear Power Plant at Zarnowlec and to the changes made for two research reactors at Swierk. The first direction, according to government decision, was cancelled at the end of 1990 and the results obtained up to now are briefly summarized. The second one is in progress, some minor changes in I and C for the EWA reactor and significant improvements for the MARIA reactor are under way. The results of this activity are presented. (author). 6 refs

  3. Active cooling for downhole instrumentation: Preliminary analysis and system selection

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, G.A.

    1988-03-01

    A feasibility study and a series of preliminary designs and analyses were done to identify candidate processes or cycles for use in active cooling systems for downhole electronic instruments. A matrix of energy types and their possible combinations was developed and the energy conversion process for each pari was identified. The feasibility study revealed conventional as well as unconventional processes and possible refrigerants and identified parameters needing further clarifications. A conceptual design or series od oesigns for each system was formulated and a preliminary analysis of each design was completed. The resulting coefficient of performance for each system was compared with the Carnot COP and all systems were ranked by decreasing COP. The system showing the best combination of COP, exchangeability to other operating conditions, failure mode, and system serviceability is chosen for use as a downhole refrigerator. 85 refs., 48 figs., 33 tabs.

  4. Evaluating the effectiveness of impact assessment instruments

    DEFF Research Database (Denmark)

    Cashmore, Matthew; Richardson, Tim; Hilding-Ryedvik, Tuija

    2010-01-01

    to sharpen effectiveness evaluation theory for impact assessment instruments this article critically examines the neglected issue of their political constitution. Analytical examples are used to concretely explore the nature and significance of the politicisation of impact assessment. It is argued......The central role of impact assessment instruments globally in policy integration initiatives has been cemented in recent years. Associated with this trend, but also reflecting political emphasis on greater accountability in certain policy sectors and a renewed focus on economic competitiveness...... that raising awareness about the political character of impact assessment instruments, in itself, is a vital step in advancing effectiveness evaluation theory. Broader theoretical lessons on the framing of evaluation research are also drawn from the political analysis. We conclude that, at least within...

  5. Organizational Member Involvement in Physical Activity Coalitions across the United States: Development and Testing of a Novel Survey Instrument for Assessing Coalition Functioning

    Science.gov (United States)

    Bornstein, Daniel B.; Pate, Russell R.; Beets, Michael W.; Saunders, Ruth P.; Blair, Steven N.

    2015-01-01

    Introduction: Coalitions are often composed of member organizations. Member involvement is thought to be associated with coalition success. No instrument currently exists for evaluating organizational member involvement in physical activity coalitions. This study aimed to develop a survey instrument for evaluating organizational member involvement…

  6. Instrument translation and initial psychometric evaluation of the Danish Body Image Quality of Life Inventory

    DEFF Research Database (Denmark)

    Rasmussen, Trine Bernholdt; Berg, Selina Kikkenborg; Dixon, Jane

    2016-01-01

    . The purpose of the study was thus to translate and validate a Danish version of the Body Image Quality of Life Inventory (BIQLI), in order to obtain a valid instrument applicable for healthcare research. METHODS: The study consisted of two phases: (i) instrument adaptation, including forward and back...... to be semantically sound, yet concerns about face validity did arise through cognitive interviews. Danish college students (n = 189, 65 men, Mage = 21.1 years) participated in the piloting of the BIQLI-DA. Convergent construct validity was demonstrated through associations to related constructs. Exploratory factor...

  7. The United Nations Basic Space Science Initiative

    Science.gov (United States)

    Haubold, Hans; Balogh, Werner

    2014-05-01

    The basic space science initiative was a long-term effort for the development of astronomy and space science through regional and international cooperation in this field on a worldwide basis, particularly in developing nations. Basic space science workshops were co-sponsored and co-organized by ESA, JAXA, and NASA. A series of workshops on basic space science was held from 1991 to 2004 (India 1991, Costa Rica and Colombia 1992, Nigeria 1993, Egypt 1994, Sri Lanka 1995, Germany 1996, Honduras 1997, Jordan 1999, France 2000, Mauritius 2001, Argentina 2002, and China 2004; http://neutrino.aquaphoenix.com/un-esa/) and addressed the status of astronomy in Asia and the Pacific, Latin America and the Caribbean, Africa, and Western Asia. Through the lead of the National Astronomical Observatory Japan, astronomical telescope facilities were inaugurated in seven developing nations and planetariums were established in twenty developing nations based on the donation of respective equipment by Japan.Pursuant to resolutions of the Committee on the Peaceful Uses of Outer Space of the United Nations (COPUOS) and its Scientific and Technical Subcommittee, since 2005, these workshops focused on the preparations for and the follow-ups to the International Heliophysical Year 2007 (UAE 2005, India 2006, Japan 2007, Bulgaria 2008, South Korea 2009; www.unoosa.org/oosa/SAP/bss/ihy2007/index.html). IHY's legacy is the current operation of 16 worldwide instrument arrays with more than 1000 instruments recording data on solar-terrestrial interaction from coronal mass ejections to variations of the total electron content in the ionosphere (http://iswisecretariat.org/). Instruments are provided to hosting institutions by entities of Armenia, Brazil, France, Israel, Japan, Switzerland, and the United States. Starting in 2010, the workshops focused on the International Space Weather Initiative (ISWI) as mandated in a three-year-work plan as part of the deliberations of COPUOS. Workshops on ISWI

  8. Trace elements in California aerosols. Part I. Instrumental neutron activation analysis techniques

    International Nuclear Information System (INIS)

    Ragaini, R.C.; Ralston, H.R.; Garvis, D.; Kaifer, R.

    1975-01-01

    Instrumental Neutron Activation Analysis (INAA) done at LLL played a key role in the 1972--1974 California Aerosol Characterization Experiment (ACHEX), a major experiment in the chemistry of aerosols in urban and non-urban sites of California sponsored by the State of California Air Resources Board. The main purpose of INAA was to measure the particle size distributions and diurnal patterns of key chemical constituents in aerosols collected in California. These data were used to satisfy some of the key objectives of ACHEX, including aerosol characterization and evaluation of the origins and evolutions of aerosols. Secondary uses of INAA were the validations of the Lundgren rotating drum cascade impactors used in the ACHEX, and validations of other analytical techniques used in the chemical analyses. As a result of these studies, it was concluded that techniques using INAA were useful operational methods for chemical analysis of aerosols collected over two-hour periods in urban air with an active monitoring program. (U.S.)

  9. SELECTED PROFESSIONAL ACTIVATION INSTRUMENTS OF WOMEN DURING PREGNANCY AND CHILDBIRTH IN POLAND

    Directory of Open Access Journals (Sweden)

    Anna Galik

    2015-03-01

    Full Text Available This article describes selected professional activation instruments of women during their pregnancy and after birth in Poland. An author indicates the main macroeconomic aggregates in the context of women's fertility and analysed available data in order to show the scale of the problem and identify a statistic picture of a woman who enters into motherhood. The article presents the situation of women, employed on the basis of the Labour Code, before and after childbirth in the context of current rights and privileges. The last part of the paper shows different forms of childcare services, their availability and limitations. The purpose of this article is to present the individual behaviour of economically active female as pregnant women, and after birth who make choices based on the available tools, selecting the most beneficial for their households. In conclusion the author identify new solutions that are beneficial for the individual, household, and the whole economy.

  10. Clinimetric properties of instruments to assess activities in patients with hand injury: a systematic review of the literature.

    NARCIS (Netherlands)

    Ven-Stevens, L.A.W. van de; Munneke, M.; Terwee, C.B.; Spauwen, P.H.M.; Linde, H. van der

    2009-01-01

    OBJECTIVE: To perform a systematic review of the literature to assess the clinimetric properties of instruments measuring limitations of activity. DATA SOURCES: The Medline, Cochrane Library, Picarta, Occupational Therapy-seeker, and CINAHL databases were searched for English or Dutch language

  11. Determination of rare earth elements in sea sediments from the Cuban northwestern coast by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Perez Zayas, G.; Pena Fortes, B.; Diaz Riso, O.; Hernandez Rivero, A.T.

    1998-01-01

    The multielemental characterization of sea sediments from an important Cuban coast was performed using instrumental Neutron activation analysis. The obtained results shown an impoverishment of in the studied zone, in comparison with the data taken from other Cuban coaster zones

  12. Instrumental neutron activation analysis of human hair and related radiotracer experiments on washing and leaching

    International Nuclear Information System (INIS)

    Das, H.A.; Hoede, D.; Sloot, H.A. van der; Herber, R.F.M.

    1981-11-01

    The work done under the IAEA-contract 2440/RB is summarized. The aim was to develop a fast and reliable system for the determination of tracer elements in human head hair by instrumental neutron activation analysis (INAA) and radiotracer washing experiments. The standardized procedure for INAA was applied to hair samples collected by the Coronel Laboratory of the University of Amsterdam. The correlation between trace element contents is considered

  13. Application of instrumental neutron activation analysis and X-ray fluorescence analysis in art pieces investigation

    International Nuclear Information System (INIS)

    Panczyk, E.; Kierzek, J.; Walis, L.; Ligeza, M.

    1996-01-01

    The application of instrumental neutron activation analysis have been shown for the trace element identification in dyes of old painting and other art objects. The recognition of their composition is a important measure for attribution. Also the X-ray fluorescence analysis has been frequently used for examination of art objects. The age determination of the old chinese porcelain is a good example described in the paper. 20 refs, 4 figs

  14. From Qualitative Data to Instrument Development: The Women's Breast Conflict Scale

    Science.gov (United States)

    Thomas, Eileen

    2011-01-01

    The purpose of this article is to describe the initial development of the Women's Breast Conflict Scale, a predictive instrument designed to identify women who may be least likely to follow recommended mammography screening guidelines. This new instrument incorporates self/body image, teasing, family norms and values, and societal/media…

  15. Automated work packages architecture: An initial set of human factors and instrumentation and controls requirements

    Energy Technology Data Exchange (ETDEWEB)

    Agarwal, Vivek [Idaho National Lab. (INL), Idaho Falls, ID (United States); Oxstrand, Johanna H. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Le Blanc, Katya L. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-09-01

    The work management process in current fleets of national nuclear power plants is so highly dependent on large technical staffs and quality of work instruction, i.e., paper-based, that this puts nuclear energy at somewhat of a long-term economic disadvantage and increase the possibility of human errors. Technologies like mobile portable devices and computer-based procedures can play a key role in improving the plant work management process, thereby increasing productivity and decreasing cost. Automated work packages are a fundamentally an enabling technology for improving worker productivity and human performance in nuclear power plants work activities because virtually every plant work activity is accomplished using some form of a work package. As part of this year’s research effort, automated work packages architecture is identified and an initial set of requirements identified, that are essential and necessary for implementation of automated work packages in nuclear power plants.

  16. Trace elements in Turkish tobacco determined by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Gulovali, M.C.

    1977-01-01

    This study was undertaken to determine the concentration of trace elements in nine different brands of Turkish cigarette tobacco, pipe tobacco and tobacco ash. Instrumental neutron activation analysis was employed, and a gamma-ray spectrometer consisting of 40 cm 3 Ge(Li) detector coupled to 1024 and 4096-channel analyzers were used. Samples were irradiated at a thermal neutron flux of about 10 13 cm -2 sec -1 . Concentrations of Na, K, Sc, Cr, Fe, Co, Zn, As, Se, Br, Rb, Sb, Cs, Ba, La, Ce, Eu, Hf, Hg and Th were determined in tobacco and ash; percent transference of these elements into ash were calculated. It was found out that trace elements in cigarette tobacco are left in the ash but only a small percentage is transferred into the smoke

  17. Instrumental neutron activation analysis (INAA) of some clayey rocks of Poland

    International Nuclear Information System (INIS)

    Janczyszyn, J.; Domanska, G.; Wyszomirski, P.

    1988-01-01

    The instrumental neutron activation analysis (INAA) was applied for determination of minor and trace element contents in some Polish clayey rocks. Lower Silesian kaolins from Wyszonowice near Strzelin and from Wadroze Wielkie near Legnica as well as allite from Kaplonosy (Lublin Coal Basin) were investigated. The contents of 26 elements were determined, including rare earth metals (Sc, La, Ce, Nd, Sm, Eu, Tb, Yb, Lu), actinides (U, Th), alkali metals (Na, K, Rb, Cs) and gold. INAA studies allowed to determine the variability of minor and trace element contents in the weathering profile in 2,5/K borehole in Wyszonowice and in size fractions separated from kaolin of Wadroze Wielkie. When using this method, the effectiveness of chemical and thermal extraction of these elements from allite of Kaplonosy was checked, too. (author)

  18. Chemical contents in Lygeum spartum L. using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Nedjimi, Bouzid

    2015-01-01

    The present investigation was conducted to determine the chemical contents of Lygeum spartum L. (Poaceae). Samples were analyzed in order to determine essential (Ca, K, Na, Fe, Co) and some potentially toxic elements (Eu, Sb, Tb) using instrumental neutron activation analysis (INAA). In general chemical element contents were in substantial amounts to meet adult sheep requirements. Potential intake of Ca, K, Zn, Co and Fe by ruminant weighing 50 kg BW consuming 2.0 kg per day DM was sufficient to satisfy their requirements. However, only Na level was still insufficient to meet the requirements for grazing ruminants. Potential toxic elements in this species were within the safety baseline of all the assayed elements recommended by NRC. Na supplementation would seem to be necessary in this zone, for optimum productivity of grazing animals.

  19. [Instrument for the assessment of middle-aged and older adults' physical activity: design, eliability and application of the German-PAQ-50+].

    Science.gov (United States)

    Huy, Christina; Schneider, Sven

    2008-06-01

    Existing physical activity questionnaires have focused either on young and middle-aged adults or on the elderly. They have mainly assessed only a portion of possible physical activities or contained nation-specific sports. As there is no gold standard for a questionnaire-based assessment of physical activity in the over-50 population, recommendations for such a questionnaire relating to German-speaking countries were developed. This work included a systematic literature research, a survey of experts, and the design of a questionnaire based on validated measuring instruments. Finally, to test its reliability and application in the field, the complete questionnaire, including a retest, was applied by telephone interview (n = 57). The test-retest-correlation was r = 0.60 for the total time of physical activity and r = 0.52 for total energy expenditure. The researchers determined that the instrument is comprehensive in its coverage of all relevant domains of physical activity for the over-50 population; it is economically feasible and showed good acceptance.

  20. The Pavlovian analysis of instrumental conditioning.

    Science.gov (United States)

    Gormezano, I; Tait, R W

    1976-01-01

    An account was given of the development within the Russian literature of a uniprocess formulation of classical and instrumental conditioning, known as the bidirectional conditioning hypothesis. The hypothesis purports to offer a single set of Pavlovian principles to account for both paradigms, based upon a neural model which assumes that bidirectional (forward and backward) connections are formed in both calssical and instrumental conditioning situations. In instrumental conditioning, the bidirectional connections are hypothesized to be simply more complex than those in classical conditioning, and any differences in empirical functions are presumed to lie not in difference in mechanism, but in the strength of the forward and backward connections. Although bidirectional connections are assumed to develop in instrumental conditioning, the experimental investigation of the bidirectional conditioning hypothesis has been essentially restricted to the classical conditioning operations of pairing two CSs (sensory preconditioning training), a US followed by a CS (backward conditioning training) and two USs. However, the paradigm involving the pairing of two USs, because of theoretical and analytical considerations, is the one most commonly employed by Russian investigators. The results of an initial experiment involving the pairing of two USs, and reference to the results of a more extensive investigation, leads us to tentatively question the validity of the bidirectional conditioning account of instrumental conditioning.

  1. Instruments used to measure or check α, β, γ activity and neutron emission in the course of processing ore or irradiated fuel

    International Nuclear Information System (INIS)

    Blanc, A.; Brunet, M.; Kermagoret, M.; Labeyrie, J.; Roux, G.; Vasseur, J.; Weil, J.

    1959-01-01

    One of the methods checking ores in the course of treatment is the rapid quantitative determination of thorium. This measurement is carried out by means of a scintillation instrument which shows the β and α coincidences of ThC and ThC'. The treatment of irradiated fuel is accompanied by a large number of radioactive checks relative to the performance of the fixation and elution operations of uranium in the ion exchangers, to the concentration of radioactivity of effluent sent from the plant into watercourses. The operations of fixation and elution of the uranium are checked automatically by an instrument which takes a sample of 5 cm 3 of solution, evaporates it and measures its activity every 10 or 20 minutes. Plutonium concentrations are measured: - in the presence of strong β γ activities, by means of rotating cylinder detectors; - in the presence of weak β γ activities, by means of α detectors scanning a constant level liquid surface; - by means of fission chambers relatively insensitive to γ. Fission product concentrations are measured by chambers, counters or scintillators, according to the amount of γ activity present. Finally, the activity of effluent to be emptied into watercourses is checked by means of a scintillation instrument, which measures the α activity on the one hand, and on the other hand the β γ activity of residue from a 100 cm 3 sample taken and evaporated in 20 minutes. (author) [fr

  2. Comparing the Psychometric Properties of Two Physical Activity Self-Efficacy Instruments in Urban, Adolescent Girls: Validity, Measurement Invariance, and Reliability

    Science.gov (United States)

    Voskuil, Vicki R.; Pierce, Steven J.; Robbins, Lorraine B.

    2017-01-01

    Aims: This study compared the psychometric properties of two self-efficacy instruments related to physical activity. Factorial validity, cross-group and longitudinal invariance, and composite reliability were examined. Methods: Secondary analysis was conducted on data from a group randomized controlled trial investigating the effect of a 17-week intervention on increasing moderate to vigorous physical activity among 5th–8th grade girls (N = 1,012). Participants completed a 6-item Physical Activity Self-Efficacy Scale (PASE) and a 7-item Self-Efficacy for Exercise Behaviors Scale (SEEB) at baseline and post-intervention. Confirmatory factor analyses for intervention and control groups were conducted with Mplus Version 7.4 using robust weighted least squares estimation. Model fit was evaluated with the chi-square index, comparative fit index, and root mean square error of approximation. Composite reliability for latent factors with ordinal indicators was computed from Mplus output using SAS 9.3. Results: Mean age of the girls was 12.2 years (SD = 0.96). One-third of the girls were obese. Girls represented a diverse sample with over 50% indicating black race and an additional 19% identifying as mixed or other race. Both instruments demonstrated configural invariance for simultaneous analysis of cross-group and longitudinal invariance based on alternative fit indices. However, simultaneous metric invariance was not met for the PASE or the SEEB instruments. Partial metric invariance for the simultaneous analysis was achieved for the PASE with one factor loading identified as non-invariant. Partial metric invariance was not met for the SEEB. Longitudinal scalar invariance was achieved for both instruments in the control group but not the intervention group. Composite reliability for the PASE ranged from 0.772 to 0.842. Reliability for the SEEB ranged from 0.719 to 0.800 indicating higher reliability for the PASE. Reliability was more stable over time in the control

  3. Instrumental Neutron Activation Analysis in archaeology interpretation beyond elemental abundance

    International Nuclear Information System (INIS)

    Bishop, Ronald L.

    2001-01-01

    Application of instrumental neutron activation analysis to the study of archaeological ceramics involves the determination of the source or sources used to produce pottery. Groups of relatively homogeneous elemental abundances are shown to be statically distinct from one another often leading to the assesment of what was locally produced and what was imported to a site. These assesment, however are among the most preliminary interpretations. Archaeology is concerned with the reasons for artificial distributions and how and why the distribution varied through time 3 reasons that include the social and political basis of ancient economics and how these responded to other factors, such as ideology. These objectives are addressed through the increasing refinement of compositional groups leading toward greater specificity of attribution. In so doing the role of analytical precision among other considerations groves in importance. This paper illustration some of these considerations with examples from the U.S. southwest, the Maya region of southern mexico, and lower central America

  4. Instrumental neutron activation analysis of prehistoric and ancient bone remains

    International Nuclear Information System (INIS)

    Vasidov, A.; Osinskaya, N.S.; Khatamov, Sh.; Rakhmanova, T.

    2008-01-01

    Instrumental neutron activation analysis (INAA) was used to study the element contents in bones of prehistoric dinosaurs and bones of an ancient bear and an archantrop (ancient person), which were found on the territory of Uzbekistan. Concentrations of more than 25 elements were in the range of 0.043-3600 mg/kg. Multielement analyses of bone and soil samples were carried out by INAA using the WWR-SM research nuclear reactor. Results of measurements have shown that in the dinosaurs bones the concentration of the rare earth elements (REEs) were within 280-3200 mg/kg; the uranium content reached a very high value, up to 180 mg/kg, while in soils coating the dinosaurs bones this content was 4.2 mg/kg; in the bones of the archantrop it was 1.53 mg/kg and in the bones of a standard person its amount is less than 0.016 mg/kg. (author)

  5. Evaluation of behaviors of earth and rockfill dams during construction and initial impounding using instrumentation data and numerical modeling

    Directory of Open Access Journals (Sweden)

    Mohammad Rashidi

    2017-08-01

    Full Text Available In this study, the behavior of Gavoshan dam was evaluated during construction and the first impounding. A two-dimensional (2D numerical analysis was conducted based on a finite difference method on the largest cross-section of the dam using the results of instrument measurements and back analysis. These evaluations will be completed in the case that back analysis is carried out in order to control the degree of the accuracy and the level of confidence of the measured behavior since each of the measurements could be controlled by comparing it to the result obtained from the numerical model. Following that, by comparing the results of the numerical analysis with the measured values, it is indicated that there is a proper consistency between these two values. Moreover, it was observed that the dam performance was suitable regarding the induced pore water pressure, the pore water pressure ratio ru, settlement, induced stresses, arching degree, and hydraulic fracturing probability during the construction and initial impounding periods. The results demonstrated that the maximum settlement of the core was 238 cm at the end of construction. In the following 6 years after construction (initial impounding and exploitation period, the accumulative settlement of the dam was 270 cm. It is clear that 88% of the total settlement of the dam took place during dam construction. The reason is that the clay core was smashed in the wet side, i.e. the optimum moisture content. Whereas the average curving ratio was 0.64 during dam construction; at the end of the initial impounding, the maximum amount of curving ratio in the upstream was 0.81, and the minimum (critical amount in the downstream was 0.52. It was also concluded that this dam is safe in comparison with the behaviors of other similar dams in the world.

  6. Higher-Level Hand Motor Function in Aging and (Preclinical) Dementia : Its Relationship with (Instrumental) Activities of Daily Life - A Mini-Review

    NARCIS (Netherlands)

    Scherder, Erik; Dekker, Welmoed; Eggermont, Laura

    2008-01-01

    A causal relationship between physical activity such as walking and cognitive functions - particularly executive functions and memory - has been observed in elderly people with and without dementia. Executive functions play an important role in the (instrumental) activities of daily life [(I)ADL].

  7. Complex of Key Instruments of Management of Operation Activity of a Small Business Trade Enterprise

    Directory of Open Access Journals (Sweden)

    Serdyuk Vira M.

    2013-11-01

    Full Text Available The article offers a complex of key instruments of management of operation activity of a small business trade enterprise, including: 1 budgeting of operation activity; 2 its accounting by norms and deviations from them; 3 monitoring of operational activity of an enterprise, which envisages analysis of revealed deviations. The article shows the most efficient way of realisation and practical use of the presented concept – application of the “standard-cost” scheme within the framework of which the following tasks are solved: 1 budgeting of income from operational activity; 2 establishment of standards of costs; 3 accumulation of data on factual income and expenditures; 4 analysis of deviations and reporting; and 5 introduction of necessary amendments. The article also offers an imitation model of analysis of dynamics of trade processes, which allows detection of key spheres of management of operation activity of a small trade enterprise and principles of carrying out an efficient and well thought over financial policy.

  8. Evaluation of Instrumentation and Dynamic Thermal Ratings for Overhead Lines

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, A. [New York Power Authority, White Plains, NY (United States)

    2013-01-31

    In 2010, a project was initiated through a partnership between the Department of Energy (DOE) and the New York Power Authority (NYPA) to evaluate EPRI's rating technology and instrumentation that can be used to monitor the thermal states of transmission lines and provide the required real-time data for real-time rating calculations. The project included the installation and maintenance of various instruments at three 230 kV line sites in northern New York. The instruments were monitored, and data collection and rating calculations were performed for about a three year period.

  9. Rare earths analysis of rock samples by instrumental neutron activation analysis, internal standard method

    International Nuclear Information System (INIS)

    Silachyov, I.

    2016-01-01

    The application of instrumental neutron activation analysis for the determination of long-lived rare earth elements (REE) in rock samples is considered in this work. Two different methods are statistically compared: the well established external standard method carried out using standard reference materials, and the internal standard method (ISM), using Fe, determined through X-ray fluorescence analysis, as an element-comparator. The ISM proved to be the more precise method for a wide range of REE contents and can be recommended for routine practice. (author)

  10. Nucleonic instruments from VUPJT Tesla

    International Nuclear Information System (INIS)

    Smola, J.

    1986-01-01

    The instruments currently produced by Tesla Premysleni are listed and briefly characterized. They include a low level alpha-beta counter, an automatic low level alpha-beta counter, detection units for environmental sample counting, instruments for measuring specific activity of liquids and radon concentration in water, a radioactive aerosol meter, dose ratemeters, portable alpha-beta indicators for surface contamintion monitoring, neutron monitors, single-, two- and three-channel spectrometric units. (M.D.)

  11. Multielement comparison of instrumental neutron activation analysis techniques using reference materials

    International Nuclear Information System (INIS)

    Ratner, R.T.; Vernetson, W.G.

    1995-01-01

    Several instrumental neutron activation analysis techniques (parametric, comparative, and k o -standardization) are evaluated using three reference materials. Each technique is applied to National Institute of Standards and Technology standard reference materials, SRM 1577a (Bovine Liver) and SRM 2704 (Buffalo River Sediment), and the United States Geological Survey standard BHVO-1 (Hawaiian Basalt Rock). Identical (but not optimum) irradiation, decay, and counting schemes are employed with each technique to provide a basis for comparison and to determine sensitivities in a routine irradiation scheme. Fifty-one elements are used in this comparison; however, several elements are not detected in the reference materials due to rigid analytical conditions (e.g. insufficient length of irradiation or activity for radioisotope of interest decaying below the lower limit of detection before counting interval). Most elements are normally distributed around certified or consensus values with a standard deviation of 10%. For some elements, discrepancies are observed and discussed. The accuracy, precision, and sensitivity of each technique are discussed by comparing the analytical results to consensus values for the Hawaiian Basalt Rock to demonstrate the diversity of multielement applications. (author) 4 refs.; 2 tabs

  12. The Sensors and Instrumentation Knowledge Transfer Network

    International Nuclear Information System (INIS)

    Cooper, P

    2009-01-01

    The Sensors and Instrumentation KTN has established itself as the UK's national network in sensors and instrumentation, developing a community of over 2,250 member organisations. This paper describes the background to Knowledge Transfer Networks (KTNs) and the changes that are happening to KTNs at a national level, before describing the market size, activities and successes of the Sensors and Instrumentation KTN. The paper concludes by describing the merger between the Sensors and Instrumentation KTN and four other KTNs to create a new KTN, with a working title of the Electronics, Sensors and Photonics KTN.

  13. Nuclear instrument maintenance and technical training in Nuclear Energy Unit

    International Nuclear Information System (INIS)

    Mohamad Nasir Abdul Wahid

    1987-01-01

    Instrument maintenance service is a necessity in a Nuclear Research Institute, such as the Nuclear Energy Unit (NEU) to ensure the smooth running of our research activities. However, realising that maintenance back-up service for either nuclear or other scientific equipment is a major problem in developing countries such as Malaysia, NEU has set up an Instrumentation and Control Department to assist in rectifying the maintenance problem. Beside supporting in house activities in NEU, the Instrumentation and Control Department (I and C) is also geared into providing services to other organisations in Malaysia. This paper will briefly outline the activities of NEU in nuclear instrument maintenance as well as in technical training. (author)

  14. Year 2000 experience with safeguards instruments

    International Nuclear Information System (INIS)

    Coffing, J.

    1999-01-01

    Presentation covers the following items concerning the experiences with safeguards instruments related to Y2K issues: initial Y2K evaluation process; improvement of Y2K testing procedure, policy of the Aquila Technologies Group, Inc. The results concerning Y2K evaluation are presented as designed in the manufacturing process in order to assure success

  15. Portable digital lock-in instrument to determine chemical constituents with single-color absorption measurements for Global Health Initiatives

    Science.gov (United States)

    Vacas-Jacques, Paulino; Linnes, Jacqueline; Young, Anna; Gerrard, Victoria; Gomez-Marquez, Jose

    2014-03-01

    Innovations in international health require the use of state-of-the-art technology to enable clinical chemistry for diagnostics of bodily fluids. We propose the implementation of a portable and affordable lock-in amplifier-based instrument that employs digital technology to perform biochemical diagnostics on blood, urine, and other fluids. The digital instrument is composed of light source and optoelectronic sensor, lock-in detection electronics, microcontroller unit, and user interface components working with either power supply or batteries. The instrument performs lock-in detection provided that three conditions are met. First, the optoelectronic signal of interest needs be encoded in the envelope of an amplitude-modulated waveform. Second, the reference signal required in the demodulation channel has to be frequency and phase locked with respect to the optoelectronic carrier signal. Third, the reference signal should be conditioned appropriately. We present three approaches to condition the signal appropriately: high-pass filtering the reference signal, precise offset tuning the reference level by low-pass filtering, and by using a voltage divider network. We assess the performance of the lock-in instrument by comparing it to a benchmark device and by determining protein concentration with single-color absorption measurements. We validate the concentration values obtained with the proposed instrument using chemical concentration measurements. Finally, we demonstrate that accurate retrieval of phase information can be achieved by using the same instrument.

  16. Portable digital lock-in instrument to determine chemical constituents with single-color absorption measurements for Global Health Initiatives

    Energy Technology Data Exchange (ETDEWEB)

    Vacas-Jacques, Paulino [Little Devices Group, SUTD-MIT International Design Center, Cambridge, Massachusetts 02139 (United States); Wellman Center for Photomedicine and Harvard Medical School, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Linnes, Jacqueline [Little Devices Group, SUTD-MIT International Design Center, Cambridge, Massachusetts 02139 (United States); Biomedical Engineering Department, Boston University, Boston, Massachusetts 02215 (United States); Young, Anna; Gomez-Marquez, Jose [Little Devices Group, SUTD-MIT International Design Center, Cambridge, Massachusetts 02139 (United States); Gerrard, Victoria [Little Devices Group, SUTD-MIT International Design Center, Cambridge, Massachusetts 02139 (United States); Opportunity Lab, Singapore University for Technology and Design, Singapore 138682 (Singapore)

    2014-03-15

    Innovations in international health require the use of state-of-the-art technology to enable clinical chemistry for diagnostics of bodily fluids. We propose the implementation of a portable and affordable lock-in amplifier-based instrument that employs digital technology to perform biochemical diagnostics on blood, urine, and other fluids. The digital instrument is composed of light source and optoelectronic sensor, lock-in detection electronics, microcontroller unit, and user interface components working with either power supply or batteries. The instrument performs lock-in detection provided that three conditions are met. First, the optoelectronic signal of interest needs be encoded in the envelope of an amplitude-modulated waveform. Second, the reference signal required in the demodulation channel has to be frequency and phase locked with respect to the optoelectronic carrier signal. Third, the reference signal should be conditioned appropriately. We present three approaches to condition the signal appropriately: high-pass filtering the reference signal, precise offset tuning the reference level by low-pass filtering, and by using a voltage divider network. We assess the performance of the lock-in instrument by comparing it to a benchmark device and by determining protein concentration with single-color absorption measurements. We validate the concentration values obtained with the proposed instrument using chemical concentration measurements. Finally, we demonstrate that accurate retrieval of phase information can be achieved by using the same instrument.

  17. Instrumental neutron activation analysis of tree rings for dendrochemical studies

    International Nuclear Information System (INIS)

    Schaumloffel, J.C.; Filby, R.H.

    1996-01-01

    Instrumental neutron activation analysis (INAA) was employed to determine zinc, cadmium and potassium concentrations in the growth rings of ponderosa pine (Pinus ponderosa Dougl.) trees growing along the shores of Lake Roosevelt in Washington State, U.S.A. where mineral processing activities have resulted in high burdens of zinc and cadmium in the lake sediments. The tree growing along the contaminated waterway display elevated concentrations of zinc in its growth rings relative to a tree growing along an uncontaminated tributary of Lake Roosevelt. Cadmium concentrations in the growth rings from both sites are similar from 1988 to 1993. Water quality data indicate an increased concentration of cadmium in the lake from 1984 to 1988. The increased concentrations of cadmium in the lake water were reflected in apparent increases in concentrations of cadmium in individual rings of the tree sampled at the contaminated site. This suggests that translocation of cadmium in the sapwood of heartwood-forming species does not occur in the short term, and thus may not be a limiting factor in using trees as environmental monitors for cadmium. In addition, five-year tree ring segments were analyzed and subsequently reanalyzed as individual single-year ring segments. The analytical data obtained for the pooled individual rings are essentially the same as for the five-year segments, demonstrating the utility of NAA for dendrochemical studies. (author). 24 refs., 5 figs., 2 tabs

  18. Summary of activities at the Engineered Barriers Test Facility, October 1, 1995 to January 31, 1997, and initial data

    International Nuclear Information System (INIS)

    Porro, I.; Keck, K.N.

    1997-03-01

    Replicates of two engineered barrier designs (a thick soil barrier and a bio/capillary barrier) were constructed in the test plots of the facility. Prior to placement of any soil in the test plots, instruments were calibrated and attached to plot instrument towers, which were then installed in the test plots. Soil from Spreading Area B was installed in the test plots in lifts and compacted. Instruments attached to the instrument tower were placed in shallow trenches dug in the lifts and buried. Each instrument was checked to make sure it functioned prior to installation of the next lift. Soil samples were collected from each lift in one plot during construction for later determination of physical and hydraulic properties. After completion of the test plots, the data acquisition system was finalized, and data collection began. Appropriate instrument calibration equations and equation coefficients are presented, and data reduction techniques are described. Initial data show test plot soils drying throughout the summer and early fall. This corresponds to low rainfall during this period. Infiltration of water into the test plots was first detected around mid-November with several subsequent episodes in December. Infiltration was verified by corresponding measurements from several different instruments ime domain reflectometry (TDR), neutron probe, thermocouple psychrometers, and heat dissipation sensors Tensiometer data does not appear to corroborate data from the other instruments. Test plots were warmer on the side closest to the access trench indicating a temperature effect from the trench. This resulted in greater soil moisture freezing with less and shallower infiltration on the far side of the plots than on the side closest to the trench. At the end of this monitoring period, infiltration in all but two of the test plots has reached the 155-cm depth. Infiltration in test plots B2 and S3 has reached only the 140-cm depth. The monitored infiltration events have not

  19. DEVELOPING MUSHROOM GYMNASTIC INSTRUMENT PROTOTYPE FOR MEN’S ARTISTIC GYMNASTIC SPORT IN CENTRAL JAVA PROVINCE

    Directory of Open Access Journals (Sweden)

    Tommy Soenyoto

    2014-03-01

    Full Text Available This study aims to develop mushroom gymnastic instrument for men’s artistic gymnastic athletes of junior and senior levels. The instrument is aimed at improving movement skills on horse saddle. Aside from its use as an exercise instrument for beginner, junior and senior levels of men’s artistic gymnastic athletes, this instrument can also be used for beginners’ level competition. This study used qualitative approach in which the data are collected from the initial step to the trial. The main procedure involved five steps: (1 the analysis of product development; (2 the development of initial product; (3 the expert validation; (4 the trial; and (5 the product revision. This study found that the mushroom gymnastic instrument can be used for men’s artistic gymnastic sport, particularly (1 for improving movement skill development on horse saddle for junior and senior athletes; (2 as an exercise instrument for beginner, junior and senior level of men’s artistic gymnastic athletes; (3 as an instrument used in competition for men’s artistic gymnastic for beginners’ level.

  20. Chemical compositions of magnetic, stony spherules from deep-sea sediments determined by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Yamakoshi, Kazuo

    1984-01-01

    Chemical compositions of magnetic, stony spherules from deep sea sediments were determined by instrumental neutron activation analysis. High Ir, Au, Ni and Co contents indicate their extraterrestrial origin. The obtained compositions are considerably different from those of chondrites. It can be qualitatively interpreted, however, that cosmic matters having the compositions of chondrites are changed into magnetic, stony spherules by thermal degenerations during their atmospheric entry. (author)

  1. Mass media image of selected instruments of economic develepment

    Directory of Open Access Journals (Sweden)

    Kruliš Ladislav

    2016-07-01

    Full Text Available The goal of this paper is twofold. Firstly, two instruments of economic development – investment incentives and cluster initiatives – were compared according to the frequency of their occurrence in selected mass media sources in the Czech Republic in the periods 2004-2005 and 2011-2012. Secondly, the mass media image of these two instruments of economic development was evaluated with respect to the frames deductively constructed from literature review. The findings pointed out a higher occurrence of the mass media articles/news dealing with investment incentives. These articles/news were, additionally, more controversial and covered a wider spectrum of frames. Politicians were a relatively more frequent type of actors who created the media message from the articles/news. On the contrary, the mass media articles/news concerning cluster initiatives typically created the frame of positive effects of clusters. The messages were told either by economic experts or by public authority representatives who were closely connected with cluster initiatives. Spatial origin of these messages was rather limited. The definitional vagueness, intangible and uncontroversial nature of cluster initiatives restrained their media appeal.

  2. Advanced Instrumentation for Ultrafast Science at the LCLS

    Energy Technology Data Exchange (ETDEWEB)

    Berrah, Nora [Univ. of Connecticut, Storrs, CT (United States)

    2015-10-13

    This grant supported a Single Investigator and Small Group Research (SISGR) application to enable multi-user research in Ultrafast Science using the Linac Coherent Light Source (LCLS), the world’s first hard x-ray free electron laser (FEL) which lased for the first time at 1.5 Å on April 20, 2009. The goal of our proposal was to enable a New Era of Science by requesting funds to purchase and build Advanced Instrumentation for Ultrafast Science (AIUS), to utilize the intense, short x-ray pulses produced by the LCLS. The proposed instrumentation will allow peer review selected users to probe the ultrasmall and capture the ultrafast. These tools will expand on the investment already made in the construction of the light source and its instrumentation in both the LCLS and LUSI projects. The AIUS will provide researchers in the AMO, Chemical, Biological and Condensed Matter communities with greater flexibility in defining their scientific agenda at the LCLS. The proposed instrumentation will complement and significantly augment the present AMO instrument (funded through the LCLS project) through detectors and capabilities not included in the initial suite of instrumentation at the facility. We have built all of the instrumentations and they have been utilized by scientists. Please see report attached.

  3. Sector activities and lessons learned around initial implementation of the United States national physical activity plan.

    Science.gov (United States)

    Evenson, Kelly R; Satinsky, Sara B

    2014-08-01

    National plans are increasingly common but infrequently evaluated. The 2010 United States National Physical Activity Plan (NPAP) provided strategies to increase population levels of physical activity. This paper describes (i) the initial accomplishments of the NPAP sector teams, and (ii) results from a process evaluation to determine how the sectors operated, their cross-sector collaboration, challenges encountered, and positive experiences. During 2011, a quarterly reporting system was developed to capture sector-level activities. A year-end interview derived more detailed information. Interviews with 12 sector leads were recorded, transcribed verbatim, and analyzed for common themes. The 6 sectors worked on goals from the implementation plan that focused broadly on education, promotion, intervention, policy, collaboration, and evaluation. Through year-end interviews, themes were generated around operations, goal setting, and cross-sector collaboration. Challenges to the NPAP work included lack of funding and time, the need for marketing and promotion, and organizational support. Positive experiences included collaboration, efficiency of work, enhanced community dynamic, and accomplishments toward NPAP goals. These initial results on the NPAP sector teams can be used as a baseline assessment for future monitoring. The lessons learned may be useful to other practitioners developing evaluations around state- or national-level plans.

  4. An instrumentation and control philosophy for high-level nuclear waste processing facilities

    International Nuclear Information System (INIS)

    Weigle, D.H.

    1990-01-01

    The purpose of this paper is to present an instrumentation and control philosophy which may be applied to high-level nuclear waste processing facilities. This philosophy describes the recommended criteria for automatic/manual control, remote/local control, remote/local display, diagnostic instrumentation, interlocks, alarm levels, and redundancy. Due to the hazardous nature of the process constituents of a high-level nuclear waste processing facility, it is imperative that safety and control features required for accident-free operation and maintenance be incorporated. A well-instrumented and controlled process, while initially more expensive in capital and design costs, is generally safer and less expensive to operate. When the long term cost savings of a well designed process is coupled with the high savings enjoyed by accident avoidance, the benefits far outweigh the initial capital and design costs

  5. Application of instrumental neutron activation analysis and multivariate statistical methods to archaeological Syrian ceramics

    International Nuclear Information System (INIS)

    Bakraji, E. H.; Othman, I.; Sarhil, A.; Al-Somel, N.

    2002-01-01

    Instrumental neutron activation analysis (INAA) has been utilized in the analysis of thirty-seven archaeological ceramics fragment samples collected from Tal AI-Wardiate site, Missiaf town, Hamma city, Syria. 36 chemical elements were determined. These elemental concentrations have been processed using two multivariate statistical methods, cluster and factor analysis in order to determine similarities and correlation between the various samples. Factor analysis confirms that samples were correctly classified by cluster analysis. The results showed that samples can be considered to be manufactured using three different sources of raw material. (author)

  6. Analysis of medicinal plants and soil sample from Haridwar region by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Maharia, R.S.; Dutta, R.K.; Acharya, R.; Reddy, A.V.R.

    2009-01-01

    Samples of leaves and stems of four medicinal plants namely Kalmegh, Amaltas, Moalshri, and Arusa were analysed by Instrumental Neutron Activation Analysis. Soil from same location was analyzed. Though concentrations of many elements were determined in the plant samples, results of selected elements namely Na, K, Mn, Fe, Co, Cr, Zn and As are discussed in this paper. The results show that all medicinal plants analyzed have lower elemental contents except Zn compared to the soil. (author)

  7. Report of the Instrumentation Service - Annex C

    International Nuclear Information System (INIS)

    Mikic, N.; Majstorovic, D.

    1993-01-01

    This report describes the tasks and organizational structure of the Instrumentation service. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment, inspection of the reactor vessel and spent fuel storage pool and describes activities related to renewal of the equipment [sr

  8. Report of the Instrumentation Service - Annex C

    International Nuclear Information System (INIS)

    Mikic, N.

    1999-01-01

    This report describes the tasks and organizational structure of the Instrumentation service. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment, inspection of the reactor vessel and spent fuel storage pool and describes activities related control and maintenace of the experimental devices [sr

  9. Report of the Instrumentation Service - Annex C

    International Nuclear Information System (INIS)

    Mikic, N.

    2000-01-01

    This report describes the tasks and organizational structure of the Instrumentation service. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment, inspection of the reactor vessel and spent fuel storage pool and describes activities related control and maintenace of the experimental devices [sr

  10. Report of the Instrumentation Service - Annex C

    International Nuclear Information System (INIS)

    Majstorovic, D.

    1986-01-01

    This report describes the tasks and organizational structure of the Instrumentation service. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment, inspection of the reactor vessel and spent fuel storage pool and describes activities related to renewal of the equipment [sr

  11. Report of the Instrumentation Service - Annex C

    International Nuclear Information System (INIS)

    Majstorovic, D.

    1988-01-01

    This report describes the tasks and organizational structure of the Instrumentation service. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment, inspection of the reactor vessel and spent fuel storage pool and describes activities related to renewal of the equipment [sr

  12. Status Report on Efforts to Enhance Instrumentation to Support Advanced Test Reactor Irradiations

    Energy Technology Data Exchange (ETDEWEB)

    J. L. Rempe; D. L. Knudson; J. E. Daw

    2011-03-01

    The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support U.S. leadership in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR NSUF facilitates basic and applied nuclear research and development, further advancing the nation's energy security needs. A key component of the ATR NSUF effort is to prove new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. To address this need, an assessment of instrumentation available and under-development at other test reactors was completed. Based on this review, recommendations were made with respect to what instrumentation is needed at the ATR; and a strategy was developed for obtaining these sensors. In 2009, a report was issued documenting this program’s strategy and initial progress toward accomplishing program objectives. In 2009, a report was issued documenting this instrumentation development strategy and initial progress toward accomplishing instrumentation development program objectives. This document reports progress toward implementing this strategy in 2010.

  13. Status Report on Efforts to Enhance Instrumentation to Support Advanced Test Reactor Irradiations

    International Nuclear Information System (INIS)

    Rempe, J.L.; Knudson, D.L.; Daw, J.E.

    2011-01-01

    The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support U.S. leadership in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR NSUF facilitates basic and applied nuclear research and development, further advancing the nation's energy security needs. A key component of the ATR NSUF effort is to prove new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. To address this need, an assessment of instrumentation available and under-development at other test reactors was completed. Based on this review, recommendations were made with respect to what instrumentation is needed at the ATR; and a strategy was developed for obtaining these sensors. In 2009, a report was issued documenting this program's strategy and initial progress toward accomplishing program objectives. In 2009, a report was issued documenting this instrumentation development strategy and initial progress toward accomplishing instrumentation development program objectives. This document reports progress toward implementing this strategy in 2010.

  14. Nondestructive assay of fluorine in geological and other materials by instrumental photon activation analysis with a microtron

    Czech Academy of Sciences Publication Activity Database

    Krausová, Ivana; Mizera, Jiří; Řanda, Zdeněk; Chvátil, David; Krist, Pavel

    2015-01-01

    Roč. 342, JAN (2015), s. 82-86 ISSN 0168-583X R&D Projects: GA ČR(CZ) GBP108/12/G108; GA ČR GA13-27885S Institutional support: RVO:61389005 Keywords : Fluorine * instrumental photon activation analysis * IPAA * coal Subject RIV: BG - Nuclear , Atomic and Molecular Physics, Colliders Impact factor: 1.389, year: 2015

  15. Cutting efficiency of Reciproc and waveOne reciprocating instruments.

    Science.gov (United States)

    Plotino, Gianluca; Giansiracusa Rubini, Alessio; Grande, Nicola M; Testarelli, Luca; Gambarini, Gianluca

    2014-08-01

    The aim of the present study was to evaluate the cutting efficiency of 2 new reciprocating instruments, Reciproc and WaveOne. Twenty-four new Reciproc R25 and 24 new WaveOne Primary files were activated by using a torque-controlled motor (Silver Reciproc) and divided into 4 groups (n = 12): group 1, Reciproc activated by Reciproc ALL program; group 2, Reciproc activated by WaveOne ALL program; group 3, WaveOne activated by Reciproc ALL program; and group 4, WaveOne activated by WaveOne ALL program. The device used for the cutting test consisted of a main frame to which a mobile plastic support for the handpiece is connected and a stainless steel block containing a Plexiglas block (inPlexiglass, Rome, Italy) against which the cutting efficiency of the instruments was tested. The length of the block cut in 1 minute was measured in a computerized program with a precision of 0.1 mm. Means and standard deviations of each group were calculated, and data were statistically analyzed with 1-way analysis of variance and Bonferroni test (P cutting efficiency than WaveOne Primary for both the movements used (P cutting efficiency than WaveOne instruments used with their proper reciprocating motion (P .05). Reciproc instruments demonstrated statistically higher cutting efficiency than WaveOne instruments. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. The effect of selected initiative and cultural activities on the self ...

    African Journals Online (AJOL)

    This study investigated the effect of selected initiative and cultural activities during an intervention programme on the self-concept of first year students at a multicultural tertiary institution. A self-concept scale based on the self-concept scale of Coopersmith (1967) and the Adolescent Sport Self-concept Scale of Vrey (1974) ...

  17. The After School Activity Initiative: Youth Helping Youth in a Community in Crisis

    Directory of Open Access Journals (Sweden)

    Brenda Robertson

    2008-03-01

    Full Text Available Youth experience considerable free time, the use of which can foster active healthy lifestyles or facilitate engagement in activities that are detrimental to self and or to society. In order for the former to occur, specific knowledge, attitudes, and skills must be acquired. This research explores an initiative in which older youth served as leaders in an after school initiative in an economically challenged community where little attention was being paid to the provision of free time opportunities for youth. Not only were positive developmental outcomes experienced by the participants (the ability to find ways to spend free time; an appreciation for the outcomes that can accrue from engagement in positive activities; and the ability to communicate effectively, but the same was true for the older youth who served as leaders (understanding the meaning of success, appreciating the power of interpersonal relationships, and becoming a role model.

  18. Study on elements concentrations on seabird feathers by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Theophilo, Carolina Y.S.; Moreira, Edson G. [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), São Paulo, SP (Brazil); Figueira, Rubens C.L.; Colabuono, Fernanda I., E-mail: carolina.theophilo@gmail.com, E-mail: emoreira@ipen.br, E-mail: rfigueira@usp.br, E-mail: ficolabuono@gmail.com [Universidade de São Paulo (USP), São Paulo, SP (Brazil). Instituto Oceanográfico

    2017-07-01

    Seabirds are very sensitive to environmental changes and because of their large longevity they are also sensitive to cumulative impacts. These birds usually occupy the higher trophic levels. White-chinned petrel (Procellaria aequinoctialis) and black-browed albatross (Thalassarche melanophris) are Procellariiformes, which is a seabird order, composed of 4 families. In the last years, researches are being done and actions are being taken to reduce the mortality of albatrosses and petrels caused by human activities. Due to the great ecological importance of these birds and the developed work with Procellariiformes, this study purpose is to quantify the Br, Cl, Cu, K, Mg, Mn, Na and V elements in white-chinned petrel and black-browed albatross feathers. Bird specimens were killed accidentally by pelagic longline fisheries operating off southern Brazil. Feathers were cleaned with acetone and then milled in a cryogenic mill. Instrumental Neutron Activation Analysis (INAA) was used for quantification of the element concentrations and measurements of induced activities were performed in a HPGe detector for gamma ray spectrometry. The obtained results on feathers showed that concentrations in these birds are not higher than others studies with the same species and, with exception of Br, there are no significant differences between elements mean concentrations in the two seabirds. (author)

  19. Study on elements concentrations on seabird feathers by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Theophilo, Carolina Y.S.; Moreira, Edson G.; Figueira, Rubens C.L.; Colabuono, Fernanda I.

    2017-01-01

    Seabirds are very sensitive to environmental changes and because of their large longevity they are also sensitive to cumulative impacts. These birds usually occupy the higher trophic levels. White-chinned petrel (Procellaria aequinoctialis) and black-browed albatross (Thalassarche melanophris) are Procellariiformes, which is a seabird order, composed of 4 families. In the last years, researches are being done and actions are being taken to reduce the mortality of albatrosses and petrels caused by human activities. Due to the great ecological importance of these birds and the developed work with Procellariiformes, this study purpose is to quantify the Br, Cl, Cu, K, Mg, Mn, Na and V elements in white-chinned petrel and black-browed albatross feathers. Bird specimens were killed accidentally by pelagic longline fisheries operating off southern Brazil. Feathers were cleaned with acetone and then milled in a cryogenic mill. Instrumental Neutron Activation Analysis (INAA) was used for quantification of the element concentrations and measurements of induced activities were performed in a HPGe detector for gamma ray spectrometry. The obtained results on feathers showed that concentrations in these birds are not higher than others studies with the same species and, with exception of Br, there are no significant differences between elements mean concentrations in the two seabirds. (author)

  20. Novel Scanning Lens Instrument for Evaluating Fresnel Lens Performance: Equipment Development and Initial Results (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Herrero, R.; Miller, D. C.; Kurtz, S. R.; Anton, I.; Sala, G.

    2013-07-01

    A system dedicated to the optical transmittance characterization of Fresnel lenses has been developed at NREL, in collaboration with the UPM. The system quantifies the optical efficiency of the lens by generating a performance map. The shape of the focused spot may also be analyzed to understand change in the lens performance. The primary instrument components (lasers and CCD detector) have been characterized to confirm their capability for performing optical transmittance measurements. Measurements performed on SoG and PMMA lenses subject to a variety of indoor conditions (e.g., UV and damp heat) identified differences in the optical efficiency of the evaluated lenses, demonstrating the ability of the Scanning Lens Instrument (SLI) to distinguish between the aged lenses.

  1. Development and evaluation of a social cognitive theory-based instrument to assess correlations for physical activity among people with spinal cord injury.

    Science.gov (United States)

    Wilroy, Jereme; Turner, Lori; Birch, David; Leaver-Dunn, Deidre; Hibberd, Elizabeth; Leeper, James

    2018-01-01

    People with spinal cord injury (SCI) are more susceptible to sedentary lifestyles because of the displacement of physical functioning and the copious barriers. Benefits of physical activity for people with SCI include physical fitness, functional capacity, social integration and psychological well-being. The purpose of this study was to develop and test a social cognitive theory-based instrument aimed to predict physical activity among people with SCI. An instrument was developed through the utilization and modification of previous items from the literature, an expert panel review, and cognitive interviewing, and tested among a sample of the SCI population using a cross-sectional design. Statistical analysis included descriptives, correlations, multiple regression, and exploratory factor analysis. The physical activity outcome variable was significantly and positively correlated with self-regulatory efficacy (r = 0.575), task self-efficacy (r = 0.491), self-regulation (r = 0.432), social support (r = 0.284), and outcome expectations (r = 0.247). Internal consistency for the constructs ranged from 0.82 to 0.96. Construct reliability values for the self-regulation (0.95), self-regulatory efficacy (0.96), task self-efficacy (0.94), social support (0.84), and outcome expectations (0.92) each exceeded the 0.70 a priori criteria. The factor analysis was conducted to seek modifications of current instrument to improve validity and reliability. The data provided support for the convergent validity of the five-factor SCT model. This study provides direction for further development of a valid and reliable instrument for predicting physical activity among people with SCI. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. The development of an automatic sample-changer and control instrumentation for isotope-source neutron-activation analysis

    International Nuclear Information System (INIS)

    Andeweg, A.H.; Watterson, J.I.W.

    1983-01-01

    An automatic sample-changer was developed at the Council for Mineral Technology for use in isotope-source neutron-activation analysis. Tests show that the sample-changer can transfer a sample of up to 3 kg in mass over a distance of 3 m within 5 s. In addition, instrumentation in the form of a three-stage sequential timer was developed to control the sequence of irradiation transfer and analysis

  3. Value addition initiatives for CANDU reactor operation performance

    International Nuclear Information System (INIS)

    Chugh, V.; Parmar, R.; Schut, J.; Sherin, J.; Xie, H.; Zobin, D.

    2013-01-01

    Recently, AMEC NSS initiated projects for CANDU® station performance engineering with potentially high returns for the utilities. This paper discusses three initiatives. Firstly, optimization of instrument calibration interval from 1 to 3 years will reduce time commitments on the maintenance resources on top of financial savings ~$3,500 per instrument. Secondly, reactor thermal power uncertainty assessment shows the level of operation which is believed to have an over-conservative margin that can be used to increase power by up to 0.75%. Finally, as an alternative means for controlling Reactor Inlet Header Temperature (RIHT), physical modifications to the High Pressure (HP) feedwater heaters can be useful for partially recovering RIHT resulting in increased production by 10-12 MWe. (author)

  4. Pollution of agricultural crops with lanthanides, thorium and uranium studied by instrumental and radiochemical neutron activation analysis

    International Nuclear Information System (INIS)

    Kucera, J.; Mizera, J.; Randa, Z.; Vavrova, M.

    2007-01-01

    The lanthanide elements, Th and U were measured in soils and agricultural crops collected in an area polluted by emissions from a phosphate fertilizer plant. Concentrations of the above elements in the soil and crop samples were determined by instrumental neutron activation analysis (INAA). Selected crop samples were also analyzed using radiochemical neutron activation analysis (RNAA) based on alkaline-oxidative fusion of the irradiated samples followed by precipitation of REE oxalates. Elevated levels of lanthanides, Th and U were found in some samples, especially in wheat chaff and parsley. (author)

  5. Use and maintenance of nuclear medicine instruments in Southeast Asia

    International Nuclear Information System (INIS)

    1983-02-01

    Nuclear medicine instruments are rather sophisticated. They are difficult to maintain in effective working condition, especially in developing countries. The present document describes a survey conducted in Bangladesh, India, Malaysia, Pakistan, Philippines, Singapore, Sri Lanka and Thailand from October 1977 to March 1978, on the use and maintenance of nuclear medicine equipment. The survey evaluated the existing problems of instrument maintenance in the 8 countries visited. The major instruments in use were (1) scintillation probe counters, (2) well scintillation counters and (3) rectilinear cameras. Gamma camera was not widely available in the region at the time of the survey. Most of the surveyed instruments were kept in a detrimental environment resulting in a high failure rate, that caused the relatively high instrument unavailability of 11%. Insufficient bureaucratic handling of repair cases, difficulties with the supply of spare- and replacement parts and lack of training proved to be the main reasons for long periods of instrument inoperation. Remedial actions, based on the survey data, have been initiated

  6. Determination of As by instrumental neutron activation analysis in sectioned hair samples for forensic purposes: chronic or acute poisoning?

    Czech Academy of Sciences Publication Activity Database

    Kučera, Jan; Kofronova, K.

    2011-01-01

    Roč. 287, č. 3 (2011), s. 769-772 ISSN 0236-5731 Institutional research plan: CEZ:AV0Z10480505 Keywords : Instrumental neutron activation analysis * Hair * Arsenic poisoning Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.520, year: 2011

  7. Developing a workplace resilience instrument.

    Science.gov (United States)

    Mallak, Larry A; Yildiz, Mustafa

    2016-05-27

    Resilience benefits from the use of protective factors, as opposed to risk factors, which are associated with vulnerability. Considerable research and instrument development has been conducted in clinical settings for patients. The need existed for an instrument to be developed in a workplace setting to measure resilience of employees. This study developed and tested a resilience instrument for employees in the workplace. The research instrument was distributed to executives and nurses working in the United States in hospital settings. Five-hundred-forty completed and usable responses were obtained. The instrument contained an inventory of workplace resilience, a job stress questionnaire, and relevant demographics. The resilience items were written based on previous work by the lead author and inspired by Weick's [1] sense-making theory. A four-factor model yielded an instrument having psychometric properties showing good model fit. Twenty items were retained for the resulting Workplace Resilience Instrument (WRI). Parallel analysis was conducted with successive iterations of exploratory and confirmatory factor analyses. Respondents were classified based on their employment with either a rural or an urban hospital. Executives had significantly higher WRI scores than nurses, controlling for gender. WRI scores were positively and significantly correlated with years of experience and the Brief Job Stress Questionnaire. An instrument to measure individual resilience in the workplace (WRI) was developed. The WRI's four factors identify dimensions of workplace resilience for use in subsequent investigations: Active Problem-Solving, Team Efficacy, Confident Sense-Making, and Bricolage.

  8. Study of atmospheric aerosols in Zaire by instrumental neutron activation analysis, atomic absorption spectrophotometry and ion-exchange chromatography

    International Nuclear Information System (INIS)

    Tshiashala, M.D.; Lumu, B.M.; Matamba, K.; Ronneau, C.

    1992-01-01

    Instrumental neutron activation analysis and atomic absorption spectroscopy were applied to the determination of trace element abundances in airborne particulate matter collected throughout Kinshasa, Zaire. Statistical treatment of the resulting data was used to assess the variations between sites and to identify the sources of the pollutants. 10 refs, 5 tabs

  9. Development of a Blood Pressure Measurement Instrument with Active Cuff Pressure Control Schemes

    Directory of Open Access Journals (Sweden)

    Chung-Hsien Kuo

    2017-01-01

    Full Text Available This paper presents an oscillometric blood pressure (BP measurement approach based on the active control schemes of cuff pressure. Compared with conventional electronic BP instruments, the novelty of the proposed BP measurement approach is to utilize a variable volume chamber which actively and stably alters the cuff pressure during inflating or deflating cycles. The variable volume chamber is operated with a closed-loop pressure control scheme, and it is activated by controlling the piston position of a single-acting cylinder driven by a screw motor. Therefore, the variable volume chamber could significantly eliminate the air turbulence disturbance during the air injection stage when compared to an air pump mechanism. Furthermore, the proposed active BP measurement approach is capable of measuring BP characteristics, including systolic blood pressure (SBP and diastolic blood pressure (DBP, during the inflating cycle. Two modes of air injection measurement (AIM and accurate dual-way measurement (ADM were proposed. According to the healthy subject experiment results, AIM reduced 34.21% and ADM reduced 15.78% of the measurement time when compared to a commercial BP monitor. Furthermore, the ADM performed much consistently (i.e., less standard deviation in the measurements when compared to a commercial BP monitor.

  10. Radiological safety related provisions and instrumentation in Indian PHWRs

    International Nuclear Information System (INIS)

    Ramamirtham, B.; Dabhadkar, S.B.; Sah, B.M.L.

    1994-01-01

    The collective radiation doses at the nuclear power plants (NPPs) world-wide have shown a significant downward trend which has resulted due to on-going efforts to keep exposures ALARA and also to meet the recently revised individual exposure limits of ICRP. In keeping with this trend a number of additional designed dose reduction features are also being incorporated in the Indian NPPs. These include better separation and shielding of radioactive systems/equipment, elimination of the use of cobalt-free materials in active systems, improved leak tightness of systems carrying heavy water, augmented ventilation and atmosphere drying systems, etc. The build-up of radiation levels in primary heat transport (PHT) system is controlled by incorporating improvements in the fuel performance and periodic system decontamination. Plant layouts have been modified, to improve the contamination control arrangements and optimum utilisation of dosimetry devices. For better control of internal exposures continuous efforts are on to make the protective gear more user-friendly. Green belts are being established around the NPPs to provide further protection against environmental impact. A number of additional radiation monitoring instruments /systems have been incorporated to provide information on radiation/activity levels, both within the plant and outside areas, particularly during emergency conditions. For processing of data provided by the large numbers of installed radiation instruments and initiating corrective/alarm actions, a computerised system (RADAS) has been provided. (author). 7 refs., 2 tabs

  11. Motivators to Adopt Green Supply Chain Initiatives

    OpenAIRE

    Amarpreet S. Kohli; Ellen Hawkins

    2015-01-01

    There are several factors that drive organizations to consider implementing green supply chain (GSC) initiatives. This paper refines an instrument to empirically test the significance of the following drivers for participation in GSC initiatives: Government Regulation, Buyer/Supply Chain Influence, Internal Readiness, Competitive Advantage, and Corporate Social Responsibility. Corporate Social Responsibility emerged as the most significant variable that effected the decision making of the org...

  12. ACTIVITY-BASED COSTING IN THE MANUFACTURING SECTOR: A MANAGERIAL INSTRUMENT FOR DECISION-MAKING

    Directory of Open Access Journals (Sweden)

    Ioana D. BUFAN

    2014-04-01

    Full Text Available The aim of this paper is to emphasize the importance of using the activity-based costing (management system in the manufacturing sector. The utility of the ABC (ABM system concerns decisions taken at a strategic and operational level. In our country, few managers understand the need for such a system and many Romanian companies use only a traditional costing system or don’t use one at all. The paper also includes a case study which is a small example of using the ABC method in a Romanian manufacturing company. The study shows that the ABC/ABM system helps managers to properly manage indirect costs (by activities and understand the profitability of products, distribution channels and customers. Therefore, it offers a powerful instrument for decision-making. Although ABC is a new system of cost calculation that is absolutely necessary, in most cases the ABC method must be implemented in addition to the traditional costing systems, which are essential for the purposes of management accounting.

  13. Evaluating the effectiveness of impact assessment instruments: Theorising the nature and implications of their political constitution

    International Nuclear Information System (INIS)

    Cashmore, Matthew; Richardson, Tim; Hilding-Ryedvik, Tuija; Emmelin, Lars

    2010-01-01

    The central role of impact assessment instruments globally in policy integration initiatives has been cemented in recent years. Associated with this trend, but also reflecting political emphasis on greater accountability in certain policy sectors and a renewed focus on economic competitiveness in Western countries, demand has increased for evidence that these instruments are effective (however defined). Resurgent interest in evaluation has not, however, been accompanied by the conceptual developments required to redress longstanding theoretical problems associated with such activities. In order to sharpen effectiveness evaluation theory for impact assessment instruments this article critically examines the neglected issue of their political constitution. Analytical examples are used to concretely explore the nature and significance of the politicisation of impact assessment. It is argued that raising awareness about the political character of impact assessment instruments, in itself, is a vital step in advancing effectiveness evaluation theory. Broader theoretical lessons on the framing of evaluation research are also drawn from the political analysis. We conclude that, at least within the contemporary research context, learning derived from analysing the meaning and implications of plural interpretations of effectiveness represents the most constructive strategy for advancing impact assessment and policy integration theory.

  14. Job/task analysis for I ampersand C [Instrumentation and Controls] instrument technicians at the High Flux Isotope Reactor

    International Nuclear Information System (INIS)

    Duke, L.L.

    1989-09-01

    To comply with Department of Energy Order 5480.XX (Draft), a job/task analysis was initiated by the Maintenance Management Department at Oak Ridge National Laboratory (ORNL). The analysis was applicable to instrument technicians working at the ORNL High Flux Isotope Reactor (HFIR). This document presents the procedures and results of that analysis. 2 refs., 2 figs

  15. Advanced Technologies and Instrumentation at the National Science Foundation

    Science.gov (United States)

    Kurczynski, Peter; Neff, James E.

    2018-01-01

    Over its more than thirty-year history, the Advanced Technologies and Instrumentation (ATI) program within the Division of Astronomical Sciences has provided grants to support the development and deployment of detectors and instrumentation for ground-based astronomy. This program has enabled scientific advances in diverse fields from solar physics to exoplanets to cosmology. ATI has provided instrumentation for both small and large observatories from radio through visible wavebands. It has played a role in the early development of major initiatives such as the Large Synoptic Survey Telescope. Technology development for astronomy unfolds over a longer period than the lifetime of a single grant. This review will consider ATI from an historical perspective to assess its impact on astronomy.

  16. An overview of process instrumentation, protective safety interlocks and alarm system at the JET facilities active gas handling system

    International Nuclear Information System (INIS)

    Skinner, N.; Brennan, P.; Brown, K.; Gibbons, C.; Jones, G.; Knipe, S.; Manning, C.; Perevezentsev, A.; Stagg, R.; Thomas, R.; Yorkshades, J.

    2003-01-01

    The Joint European Torus (JET) Facilities Active Gas Handling System (AGHS) comprises ten interconnected processing sub-systems that supply, process and recover tritium from gases used in the JET Machine. Operations require a diverse range of process instrumentation to carry out a multiplicity of monitoring and control tasks and approximately 500 process variables are measured. The different types and application of process instruments are presented with specially adapted or custom-built versions highlighted. Forming part of the Safety Case for tritium operations, a dedicated hardwired interlock and alarm system provides an essential safety function. In the event of failure modes, each hardwired interlock will back-up software interlocks and shutdown areas of plant to a failsafe condition. Design of the interlock and alarm system is outlined and general methodology described. Practical experience gained during plant operations is summarised and the methods employed for routine functional testing of essential instrument systems explained

  17. Determination of the plutonium content in a spent fuel assembly by passive and active interrogation using a differential die-away instrument

    Energy Technology Data Exchange (ETDEWEB)

    Henzl, V., E-mail: henzl@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM 87544 (United States); Croft, S.; Richard, J.; Swinhoe, M.T.; Tobin, S.J. [Los Alamos National Laboratory, Los Alamos, NM 87544 (United States)

    2013-06-01

    In this paper, we present a novel approach to estimating the total plutonium content in a spent fuel assembly (SFA) that is based on combining information from a passive measurement of the total neutron count rate (PN) of the assayed SFA and a measure of its multiplication. While PN can be measured essentially with any non-destructive assay (NDA) technique capable of neutron detection, the measure of multiplication is, in our approach, determined by means of active interrogation using an instrument based on the Differential Die-Away technique (DDA). The DDA is a NDA technique developed within the U.S. Department of Energy's Next Generation Safeguards Initiative (NGSI) project focused on the utilization of NDA techniques to determine the elemental plutonium content in commercial nuclear SFA's [1]. This approach was adopted since DDA also allows determination of other SFA characteristics, such as burnup, initial enrichment, and cooling time, and also allows for detection of certain types of diversion of nuclear material. The quantification of total plutonium is obtained using an analytical correlation function in terms of the observed PN and active multiplication. Although somewhat similar approaches relating Pu content with PN have been adopted in the past, we demonstrate by extensive simulation of the fuel irradiation and NDA process that our analytical method is independent of explicit knowledge of the initial enrichment, burnup, and an absolute value of the SFA's reactivity (i.e. multiplication factor). We show that when tested with MCNPX{sup ™} simulations comprising the 64 SFA NGSI Spent Fuel Library-1 we were able to determine elemental plutonium content, using just a few calibration parameters, with an average variation in the prediction of around 1–2% across the wide dynamic range of irradiation history parameters used, namely initial enrichment (IE=2–5%), burnup (BU=15–60 GWd/tU) and cooling time (CT=1–80 y). In this paper we

  18. Instrumentation maintenance

    International Nuclear Information System (INIS)

    Mack, D.A.

    1976-09-01

    It is essential to any research activity that accurate and efficient measurements be made for the experimental parameters under consideration for each individual experiment or test. Satisfactory measurements in turn depend upon having the necessary instruments and the capability of ensuring that they are performing within their intended specifications. This latter requirement can only be achieved by providing an adequate maintenance facility, staffed with personnel competent to understand the problems associated with instrument adjustment and repair. The Instrument Repair Shop at the Lawrence Berkeley Laboratory is designed to achieve this end. The organization, staffing and operation of this system is discussed. Maintenance policy should be based on studies of (1) preventive vs. catastrophic maintenance, (2) records indicating when equipment should be replaced rather than repaired and (3) priorities established to indicate the order in which equipment should be repaired. Upon establishing a workable maintenance policy, the staff should be instructed so that they may provide appropriate scheduled preventive maintenance, calibration and corrective procedures, and emergency repairs. The education, training and experience of the maintenance staff is discussed along with the organization for an efficient operation. The layout of the various repair shops is described in the light of laboratory space and financial constraints

  19. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    International Nuclear Information System (INIS)

    Baumgartner, A.; Maringer, F.J.; Michai, P.; Kreuziger, M.

    2006-01-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  20. Increased activity of pre-motor network does not change the excitability of motoneurons during protracted scratch initiation

    DEFF Research Database (Denmark)

    Guzulaitis, Robertas; Alaburda, Aidas; Hounsgaard, Jørn Dybkjær

    2013-01-01

    of their intrinsic excitability. Here we employed an experimental paradigm of protracted scratch initiation in the integrated carapace-spinal cord preparation of adult turtles (Chrysemys scripta elegans). The protracted initiation of scratch network activity allows us to investigate the excitability of motoneurons...... and pre-motor network activity in the time interval from the start of sensory stimulation until the onset of scratch activity. Our results suggest that increased activity in the pre-motor network facilitates the onset of scratch episodes but does not change the excitability of motoneurons at the onset...... of scratching....

  1. Instrumental neutron activation analysis of proposed marine sediment reference material (IAEA-158)

    International Nuclear Information System (INIS)

    Siddique, N.; Waheed, S.

    2009-01-01

    IAEA-158, sediment prepared by the International Atomic Energy Agency -Marine Environmental Laboratory (IAEA-MEL), Monaco was received under the IAEA Analytical Quality Control Services (AQCS) Intercomparison Programme. Instrumental Neutron Activation Analysis (INAA) was used to determine AI, As, Br, Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Mn, Na, Nd, Rb, Sb, Sc, Se, Sm, Ta, Tb, Th, V, Vb and Zn in this proposed reference material (RM). Four different irradiation protocols were adopted using a miniature neutron source reactor (MNSR) by varying the irradiation, cooling and counting times. IAEA-405 (Estuarine Sediment) and IAEA-SLI (Lake Sediment) were used as compatible matrix reference materials for quality assurance (QA) purposes. Good agreement between our data and lAEA certified values was obtained providing confidence in the reported data. (author)

  2. Direct payments as an instrument of the environmental policy Płatności obszarowe jako instrument polityki ochrony środowiska

    Directory of Open Access Journals (Sweden)

    Adrian Sadłowski

    2011-12-01

    Full Text Available Agriculture is the area of human activity that is accompanied by the formation of positive and negative external environmental effects. In order to motivate farmers to conduct production activities in a way that reduces the negative impact of these activities on the environment, the so-called principle of cross compliance has been incorporated into the direct support system. This study characterises the area payments as an instrument of the environmental policy and is a review of the European Commission’s different proposals for the reform of direct payments through the prism of environmental functions of this instrument.

  3. Nuclear instrumentation

    International Nuclear Information System (INIS)

    Weill, Jacky; Fabre, Rene.

    1981-01-01

    This article sums up the Research and Development effort at present being carried out in the five following fields of applications: Health physics and Radioprospection, Control of nuclear reactors, Plant control (preparation and reprocessing of the fuel, testing of nuclear substances, etc.), Research laboratory instrumentation, Detectors. It also sets the place of French industrial activities by means of an estimate of the French market, production and flow of trading with other countries [fr

  4. Risk management in technovigilance: construction and validation of a medical-hospital product evaluation instrument.

    Science.gov (United States)

    Kuwabara, Cleuza Catsue Takeda; Evora, Yolanda Dora Martinez; de Oliveira, Márcio Mattos Borges

    2010-01-01

    With the continuous incorporation of health technologies, hospital risk management should be implemented to systemize the monitoring of adverse effects, performing actions to control and eliminate their damage. As part of these actions, Technovigilance is active in the procedures of acquisition, use and quality control of health products and equipment. This study aimed to construct and validate an instrument to evaluate medical-hospital products. This is a quantitative, exploratory, longitudinal and methodological development study, based on the Six Sigma quality management model, which has as its principle basis the component stages of the DMAIC Cycle. For data collection and content validation, the Delphi technique was used with professionals from the Brazilian Sentinel Hospital Network. It was concluded that the instrument developed permitted the evaluation of the product, differentiating between the results of the tested brands, in line with the initial study goal of qualifying the evaluations performed.

  5. Analysis of marine sediment and lobster hepatopancreas reference materials by instrumental photon activation

    International Nuclear Information System (INIS)

    Landsberger, S.; Davidson, W.F.

    1985-01-01

    By use of instrumental photon activation analysis, twelve trace (As, Ba, Cr, Co, Mn, Ni, Pb, Sb, Sr, U, Zn, and Zr) and eight minor (C, Na, Mg, Co, K, Ca, Tl, and Fe) elements were determined in a certified marine sediment standard reference material as well as eight trace (Mn, Ni, Cu, Zn, As, Sr, Cd, and Pb) and four minor (Na, Mg, Cl, and Ca) elements in a certified marine tissue (lobster hepatopancreas) standard reference material. The precision and accuracy of the present results when compared to the accepted values clearly demonstrate the reliability of this nondestructive technique and its applicability to marine environmental or marine geochemical studies. 24 references, 4 figures, 3 tables

  6. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. An inspector-instrument interface design that allows communication of procedures, responses, and results between the instrument and user is presented. This capability has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  7. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. This report describes an inspector-instrument interface design which allows communication of procedures, responses, and results between the instrument and user. The interface has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  8. Application of instrumented nanoindentation in preformulation studies of pharmaceutical active ingredients and excipients

    Directory of Open Access Journals (Sweden)

    Egart Mateja

    2016-09-01

    Full Text Available Nanoindentation allows quantitative determination of a material’s response to stress such as elastic and plastic deformation or fracture tendency. Key instruments that have enabled great advances in nanomechanical studies are the instrumented nanoindenter and atomic force microscopy. The versatility of these instruments lies in their capability to measure local mechanical response, in very small volumes and depths, while monitoring time, displacement and force with high accuracy and precision.

  9. Teachers’ perceptions of their own initiative: Collective initiative vs. personal initiative

    Directory of Open Access Journals (Sweden)

    Džinović Vladimir

    2013-01-01

    Full Text Available Current trends in education demand from teachers to exhibit proactive behaviour and assume responsibility for the implementation of changes in school practice. In that sense, it is important to study how teachers perceive their own initiative and to gain insight into the activities where such initiative is demonstrated. This study has been conceived as a mixed-methods research. The qualitative study implied forming four focus groups with subject teachers and class teachers (N=38, while the quantitative study entailed surveying 1441 teachers in forty primary schools in Serbia using the questionnaire constructed based on qualitative data. Data from focus groups were processed by qualitative thematic analysis, while the questionnaire data were processed by principal component analysis and univariate analysis of variance. The findings of the study have shown that teachers mostly demonstrate initiative through co­operative activities that include planning of joint teaching as well as conducting joint projects within school and with the local community actors. Teachers are least ready to demonstrate personal initiative and the initiative aimed at accomplishing considerable changes in school work. The concluding part includes the recommendations for encouraging teachers’ personal initiative and building organizational culture that would support such initiative. [Projekat Ministarstva nauke Republike Srbije, br. br. 47008: Unapređivanje kvaliteta i dostupnosti obrazovanja u procesima modernizacije Srbije i br. 179034: Od podsticanja inicijative, saradnje i stvaralaštva u obrazovanju do novih uloga i identiteta u društvu

  10. Epac Activation Initiates Associative Odor Preference Memories in the Rat Pup

    Science.gov (United States)

    Grimes, Matthew T.; Powell, Maria; Gutierrez, Sandra Mohammed; Darby-King, Andrea; Harley, Carolyn W.; McLean, John H.

    2015-01-01

    Here we examine the role of the exchange protein directly activated by cAMP (Epac) in ß-adrenergic-dependent associative odor preference learning in rat pups. Bulbar Epac agonist (8-pCPT-2-O-Me-cAMP, or 8-pCPT) infusions, paired with odor, initiated preference learning, which was selective for the paired odor. Interestingly, pairing odor with Epac…

  11. Comparative effectiveness of manipulation, mobilisation and the Activator instrument in treatment of non-specific neck pain: a systematic review

    Directory of Open Access Journals (Sweden)

    Miller Peter

    2006-04-01

    Full Text Available Abstract Background Neck pain is a common problem and different forms of manual therapy are used in its treatment. The purpose of this systematic review was to critically appraise the literature that directly compared manipulation, mobilisation and the Activator instrument for non-specific neck pain. Methods Electronic databases (MEDLINE, MANTIS and CINAHL were searched from their inception to October 2005 for all English language randomised clinical trials that directly compared manipulation, mobilisation and the Activator instrument. Inclusion and exclusion criteria were applied to select the studies and these studies were then evaluated using validated criteria. Results Five such studies were identified. The methodological quality was mostly poor. Findings from the studies were mixed and no one therapy was shown to be more effective than the others. Conclusion Further high quality research has to be done before a recommendation can be made as to the most effective manual method for non-specific neck pain.

  12. SfDredd, a Novel Initiator Caspase Possessing Activity on Effector Caspase Substrates in Spodoptera frugiperda.

    Science.gov (United States)

    Yang, Zhouning; Zhou, Ke; Liu, Hao; Wu, Andong; Mei, Long; Liu, Qingzhen

    2016-01-01

    Sf9, a cell line derived from Spodoptera frugiperda, is an ideal model organism for studying insect apoptosis. The first notable study that attempted to identify the apoptotic pathway in Sf9 was performed in 1997 and included the discovery of Sf-caspase-1, an effector caspase of Sf9. However, it was not until 2013 that the first initiator caspase in Sf9, SfDronc, was discovered, and the apoptotic pathway in Sf9 became clearer. In this study, we report another caspase of Sf9, SfDredd. SfDredd is highly similar to insect initiator caspase Dredd homologs. Experimentally, recombinant SfDredd underwent autocleavage and exhibited different efficiencies in cleavage of synthetic caspase substrates. This was attributed to its caspase activity for the predicted active site mutation blocked the above autocleavage and synthetic caspase substrates cleavage activity. SfDredd was capable of not only cleaving Sf-caspase-1 in vitro but also cleaving Sf-caspase-1 and inducing apoptosis when it was co-expressed with Sf-caspase-1 in Sf9 cells. The protein level of SfDredd was increased when Sf9 cells were treated by Actinomycin D, whereas silencing of SfDredd reduced apoptosis and Sf-caspase-1 cleavage induced by Actinomycin D treatment. These results clearly indicate that SfDredd functioned as an apoptotic initiator caspase. Apoptosis induced in Sf9 cells by overexpression of SfDredd alone was not as obvious as that induced by SfDronc alone, and the cleavage sites of Sf-caspase-1 for SfDredd and SfDronc are different. In addition, despite sharing a sequence homology with initiator caspases and possessing weak activity on initiator caspase substrates, SfDredd showed strong activity on effector caspase substrates, making it the only insect caspase reported so far functioning similar to human caspase-2 in this aspect. We believe that the discovery of SfDredd, and its different properties from SfDronc, will improve the understanding of apoptosis pathway in Sf9 cells.

  13. DEVELOPING EVALUATION INSTRUMENT FOR MATHEMATICS EDUCATIONAL SOFTWARE

    Directory of Open Access Journals (Sweden)

    Wahyu Setyaningrum

    2012-02-01

    Full Text Available The rapid increase and availability of mathematics software, either for classroom or individual learning activities, presents a challenge for teachers. It has been argued that many products are limited in quality. Some of the more commonly used software products have been criticized for poor content, activities which fail to address some learning issues, poor graphics presentation, inadequate documentation, and other technical problems. The challenge for schools is to ensure that the educational software used in classrooms is appropriate and effective in supporting intended outcomes and goals. This paper aimed to develop instrument for evaluating mathematics educational software in order to help teachers in selecting the appropriate software. The instrument considers the notion of educational including content, teaching and learning skill, interaction, and feedback and error correction; and technical aspects of educational software including design, clarity, assessment and documentation, cost and hardware and software interdependence. The instrument use a checklist approach, the easier and effective methods in assessing the quality of educational software, thus the user needs to put tick in each criteria. The criteria in this instrument are adapted and extended from standard evaluation instrument in several references.   Keywords: mathematics educational software, educational aspect, technical aspect.

  14. Determination of sodium in biological samples by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Parwate, D.V.; Garg, A.N.

    1981-01-01

    Sodium is one of the most essential elements needed for metabolic processes amongst human beings. It is consumed in the form of sodium chloride but it is also present in edible plant leaves. Sodium is mostly analyzed by flame photometric method, a destructive and time consuming technique. Sodium has been determined in some green leave vegetables samples-palak, radish, khatta palak (ambat chuka), chaulai leaves, chauli bean covers and its seeds by instrumental neutron activation analysis. The method involves irradiation of samples with thermal neutrons from 241 Am-Be source and counting 24 Na activity (half life 15 hr) from the reaction 23 Na(n,γ) 24 Na. Activity due to 1.37 MeV photopeak was counted with a NaI(Tl) crystal coupled to gamma ray spectrometer. Green leaves of the vegetables were thoroughly washed, dried at constant temperature and powdered. Bowen's Kale powder was used as standard for measuring sodium abundances. About 2g each of samples and the standard were packed in polythene vials. They were irradiated for 24 hrs, delayed by 1 hr and then counted for 20 mts. It is found that radish leaves are most enriched in sodium (14.0 +-0.45%) amongst four leave samples analyzed. For three different parts of chaulai leaves, bean covers and seeds, sodium contents are 1.38%, 1820 and 1010 ppm. Palak contains 2.84 +-0.29% while khatta palak contains only 4210 +- 830 ppm sodium. All values reported here are for dry weight samples and are means of three replicate measurements with standard deviation. (author)

  15. Optomechanical Design of a Hard X-ray Nanoprobe Instrument with Nanometer-Scale Active Vibration Control

    International Nuclear Information System (INIS)

    Shu, D.; Preissner, C.; Smolyanitskiy, A.; Maser, J.; Winarski, R.; Holt, M.; Lai, B.; Vogt, S.; Stephenson, G. B.

    2007-01-01

    We are developing a new hard x-ray nanoprobe instrument that is one of the centerpieces of the characterization facilities of the Center for Nanoscale Materials being constructed at Argonne National Laboratory. This new probe will cover an energy range of 3-30 keV with 30-nm spacial resolution. The system is designed to accommodate x-ray optics with a resolution limit of 10 nm, therefore, it requires staging of x-ray optics and specimens with a mechanical repeatability of better than 5 nm. Fast feedback for differential vibration control between the zone-plate x-ray optics and the sample holder has been implemented in the design using a digital-signal-processor-based real-time closed-loop feedback technique. A specially designed, custom-built laser Doppler displacement meter system provides two-dimensional differential displacement measurements with subnanometer resolution between the zone-plate x-ray optics and the sample holder. The optomechanical design of the instrument positioning stage system with nanometer-scale active vibration control is presented in this paper

  16. Study of trace metals in phosphorite by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Delgado, J.U.

    1984-01-01

    Methods to determine U, Th and other constituent elements in mineral matrices by the instrumental neutron activation analysis (INAA) have been widely developed. The precise knowledge of these constituent elements is very important for the nuclear technology development. This justifies the use of a technique capable to extract information from small samples. The present work aimed the study of the phosphorites deriving from the State of Pernambuco (PE, Brazil). Its uranium concentration corresponds to one of the highest values found in industrial exploration of phosphate rocks. An experimental methodology based on the INAA associated to the cluster technique was developed. Concentrations of 22 different elements present in the ore were determined with less than 10% uncertainty. The results have shown high correlations in behavior between uranium and rare earth metals. However, the inverse was noted in relation to transition metals. These results indicate the applicability of this method to determine concentrations as well as to classify correlated element groups in mineral matrices. (Author) [pt

  17. New developments in radiation protection instrumentation via active electronic methods

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1981-01-01

    New developments in electronics and radiation detectors are improving on real-time data acquisition of radiation exposure and contamination conditions. Recent developments in low power circuit designs, hybrid and integrated circuits, and microcomputers have all contributed to smaller and lighter radiation detection instruments that are, at the same time, more sensitive and provide more information (e.g., radioisotope identification) than previous devices. New developments in radiation detectors, such as cadmium telluride, gas scintillation proportional counters, and imaging counters (both charged particle and photon) promise higher sensitivities and expanded uses over present instruments. These developments are being applied in such areas as health physics, waste management, environmental monitoring, in vivo measurements, and nuclear safeguards

  18. Study of starburst galaxies and active galactic nuclei in the mid-infrared with the ISOCAM instrument

    International Nuclear Information System (INIS)

    Laurent, Olivier

    1999-01-01

    This thesis is dedicated to the study of starburst galaxies and active galactic nuclei (AGNs) in the mid-infrared between 3 and 16 μm with the ISOCAM instrument. The study of nearby prototypical galaxies such as NGC 1068 and M 82 lead me to decompose the emission into three components. The star forming regions are characterized by (1) the infrared bands at 6.2, 7.7, 8.6, 11.3 and 12.7 μm originating from the photo-dissociation regions and also by (2) a continuum at 15 μm produced by the very small grains in HII regions. I show that AGNs have (3) strong continuum with an important contribution between 3 and 10 μm arising from hot dust heated to high temperatures of the order of 1000 K. I present two diagnostic diagrams based on the spectral properties of the three components allowing me to distinguish AGNs from starburst regions. In interacting galaxies, I show that some extra-nuclear regions harboring starburst activity can dominate the emission at 15 μm as in the Cartwheel and the Antennae galaxies. Using mid-infrared spectral features, I also define two prototypes of ultra-luminous galaxies dominated either by starburst activity in the case of Arp 220 or by the AGN in the Super-Antennae galaxy (IRAS 19254-7245). I explain how this diagram and the selection criteria evolve according to redshift. Finally, I show how we can develop new diagnostics using filters of the IRAC instrument on board the next infrared space observatory SIRTF. (author) [fr

  19. Calibration through on-line monitoring of instruments channels

    International Nuclear Information System (INIS)

    James, R.W.

    1996-01-01

    Plant technical specifications require periodic calibration of instrument channels, and this has traditionally meant calibration at fixed time intervals for nearly all instruments. Experience has shown that unnecessarily frequent calibrations reduce channel availability and reliability, impact outage durations, and increase maintenance costs. An alternative approach to satisfying existing requirements for periodic calibration consists of on-line monitoring and quantitative comparison of instrument channels during operation to identify instrument degradation and failure. A Utility Working Group has been formed by EPRI to support the technical activities necessary to achieve generic NRC acceptance of on-line monitoring of redundant instrument channels as a basis for determining when to perform calibrations. A topical report proposing NRC acceptance of this approach was submitted in August 1995, and the Working Group is currently resolving NRC technical questions. This paper describes the proposed approach and the current status of the topical report with regard to NRC review. While these activities will not preclude utilities from continuing to use existing calibration approaches, successful acceptance of this performance-based approach will allow utilities to substantially reduce the number of calibrations which are performed. Concurrent benefits will include reduced I ampersand C impact on outage durations and improved sensitivity to instrument channel performance

  20. Activation Kinetics and Off-Target Effects of Thymus-Initiated Cre Transgenes

    Science.gov (United States)

    Shi, Jianjun; Petrie, Howard T.

    2012-01-01

    The bacteriophage enzyme Cre is a site-specific recombinase widely used to delete loxP-flanked DNA sequences in lineage-specific fashion. Several mouse lines that direct Cre expression to lymphoid progenitors in the thymus have been established, but a side-by-side comparison of when they first become active, and/or their relative efficiency at various developmental stages, has been lacking. In this study, we evaluated these in four common Cre transgenic strains with thymus-initiated promoters (Lck, Cd2, or Cd4). We found that while all of them eventually labeled nearly all thymocytes, their kinetics were dramatically different, and other than Cd4[Cre], did not faithfully recapitulate the expression pattern of the corresponding endogenous gene. Perhaps even more importantly, while thymuses from some strains compared favorably to thymuses from control (Cre-negative) mice, we found that Cre expression could also result in off-target effects, including moderate to severe decreases in thymic cellularity. These effects occurred in the absence of loxP-flanked DNA target genes, and were dose and copy number dependent. Loss of cellularity was attributable to a specific decrease in CD4+8+ immature cells, and corresponds to an increased rate of programmed cell death. In addition to a comprehensive analysis of activation kinetics in thymus-initiated Cre transgenes, our data show that Cre is toxic to CD4+8+ cells in a dose-dependent fashion, and emphasize that the choice of thymus-initiated Cre strain is critically important for minimizing off-target effects of Cre. PMID:23049709

  1. Radioactive standards and calibration methods for contamination monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Makoto [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-06-01

    Contamination monitoring in the facilities for handling unsealed radioactive materials is one of the most important procedures for radiation protection as well as radiation dose monitoring. For implementation of the proper contamination monitoring, radiation measuring instruments should not only be suitable to the purpose of monitoring, but also be well calibrated for the objective qualities of measurement. In the calibration of contamination monitoring instruments, quality reference activities need to be used. They are supplied in different such as extended sources, radioactive solutions or radioactive gases. These reference activities must be traceable to the national standards or equivalent standards. On the other hand, the appropriate calibration methods must be applied for each type of contamination monitoring instruments. In this paper, the concepts of calibration for contamination monitoring instruments, reference sources, determination methods of reference quantities and practical calibration methods of contamination monitoring instruments, including the procedures carried out in Japan Atomic Energy Research Institute and some relevant experimental data. (G.K.)

  2. Systematizing the Instruments of Trade Wars and of Concealed Protectionism

    Directory of Open Access Journals (Sweden)

    Serpukhov Maksym Yu.

    2017-11-01

    Full Text Available The article is concerned with the problems of trade wars and hidden protectionism in the process of implementing international trade. The main purpose of the research is systematization of trade barriers and instruments used in the trade wars between countries. The basic instruments of trade wars have been analyzed, a list of the key instruments used in the trade wars between countries has been defined, and also the possible influence of these instruments has been described. The statistical analysis has resulted in identifying the main trade barriers and the most popular sectors of the economy in which protectionism instruments are applied. The authors have also defined the main interventions applied by different world countries in relation to Ukrainian products and groups of Ukrainian goods to which the most restrictions by the world countries are applied. The conclusions on counteraction and adaptation to the most popular instruments of protectionism in the process of activation of the export activity of country have been generalized.

  3. Gearbox Instrumentation for the Investigation of Bearing Axial Cracking

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lambert, Scott R [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-03-27

    Failures in gearbox bearings have been the primary source of reliability issues for wind turbine drivetrains, leading to costly downtime and unplanned maintenance. The most common failure mode is attributed to so-called axial cracks or white-etching cracks, which primarily affect the intermediate and high-speed-stage bearings. The high-speed-shaft and bearing loads and sliding will be measured with a specially instrumented gearbox installed in a 1.5-megawatt turbine at the National Wind Technology Center in an upcoming test campaign. Additional instrumentation will also measure the tribological environment of these bearings, including bearing temperatures, lubricant temperature and water content, air temperature and humidity, and stray electrical current across the bearings. This paper fully describes the instrumentation package and summarizes initial results.

  4. Patient-Reported Outcome and Quality of Life Instruments Database (PROQOLID: Frequently asked questions

    Directory of Open Access Journals (Sweden)

    Perrier Laure-Lou

    2005-03-01

    Full Text Available Abstract The exponential development of Patient-Reported Outcomes (PRO measures in clinical research has led to the creation of the Patient-Reported Outcome and Quality of Life Instruments Database (PROQOLID to facilitate the selection process of PRO measures in clinical research. The project was initiated by Mapi Research Trust in Lyon, France. Initially called QOLID (Quality of Life Instruments Database, the project's purpose was to provide all those involved in health care evaluation with a comprehensive and unique source of information on PRO and HRQOL measures available through the Internet. PROQOLID currently describes more than 470 PRO instruments in a structured format. It is available in two levels, non-subscribers and subscribers, at http://www.proqolid.org. The first level is free of charge and contains 14 categories of basic useful information on the instruments (e.g. author, objective, original language, list of existing translations, etc.. The second level provides significantly more information about the instruments. It includes review copies of over 350 original instruments, 120 user manuals and 350 translations. Most are available in PDF format. This level is only accessible to annual subscribers. PROQOLID is updated in close collaboration with the instruments' authors on a regular basis. Fifty or more new instruments are added to the database annually. Today, all of the major pharmaceutical companies, prestigious institutions (such as the FDA, the NIH's National Cancer Institute, the U.S. Veterans Administration, dozens of universities, public institutions and researchers subscribe to PROQOLID on a yearly basis. More than 800 users per day routinely visit the database.

  5. Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982

    Energy Technology Data Exchange (ETDEWEB)

    Klobe, L.E.E. (ed.)

    1982-12-01

    Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; gas centrifuge enrichment technology support; Advanced Instrumentation for Reflood Studies (AIDRS) program; instrumentation development support for fuel reprocessing; in-core experiments and reactor systems; energy, conservation, and electric power systems; computer systems; measurements research; and fossil energy studies Publications are listed. (WHK)

  6. Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982

    International Nuclear Information System (INIS)

    Klobe, L.E.E.

    1982-12-01

    Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced #betta# and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; gas centrifuge enrichment technology support; Advanced Instrumentation for Reflood Studies (AIDRS) program; instrumentation development support for fuel reprocessing; in-core experiments and reactor systems; energy, conservation, and electric power systems; computer systems; measurements research; and fossil energy studies Publications are listed

  7. Instrument evaluation no. 18. Mini instruments contamination meter type 5.10 EL

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1980-04-01

    An evaluation is given of the general purpose contamination monitor, the Mini-Instruments Type 5-10EL which comprises a probe connected by a coiled extensible cable to a ratemeter. The facilities and controls, radiation characteristics, electrical characteristics, environmental effects, mechanical characteristics, and the manual are considered. A summary is given of the instrument's performance showing that it is a useful general-purpose contamination monitor suitable for the monitoring of beta contamination at a level for non-active areas of 1 DL (3.7 Bq cm -2 (10 -4 μCi cm -2 )) for beta emitters of maximum energy at least that of 14 C, given a normal environmental gamma background. (U.K.)

  8. Music@Home: A novel instrument to assess the home musical environment in the early years.

    Science.gov (United States)

    Politimou, Nina; Stewart, Lauren; Müllensiefen, Daniel; Franco, Fabia

    2018-01-01

    The majority of children under the age of 5 appear to show spontaneous enjoyment of singing, being exposed to music and interacting with musical instruments, but whether variations in engaging in such activities in the home could contribute to developmental outcomes is still largely unknown. Critically, researchers lack a comprehensive instrument with good psychometric properties to assess the home musical environment from infancy to the preschool years. To address this gap, this paper presents two studies that describe the development and validation of the Music@Home questionnaire, which comprises two versions: Infant and Preschool. In Study 1, an initial pool of items was generated and administered to a wide audience of parents (n = 287 for the Infant, n = 347 for the Preschool version). Exploratory factor analysis was used to identify different dimensions comprising the home musical environment of both infants and pre-schoolers, and to reduce the initial pool of items to a smaller number of meaningful items. In Study 2, convergent and divergent validity and internal and test-retest reliability of the new instrument were established, using data from a different sample of participants (n = 213 for the Infant, n = 213 for the Preschool version). The second study also investigated associations between the Music@Home and musical characteristics of the parents, such as their musical education and personal engagement with music. Overall, the Music@Home constitutes a novel, valid and reliable instrument that allows for the systematic assessment of distinct aspects of the home musical environment in families with children under the age of 5. Furthermore, the Infant and Preschool versions of the Music@Home present differential associations with musical characteristics of the parents opening a new area of inquiry into how musical exposure and interaction in the home may vary across different developmental stages.

  9. Music@Home: A novel instrument to assess the home musical environment in the early years

    Science.gov (United States)

    Stewart, Lauren; Müllensiefen, Daniel; Franco, Fabia

    2018-01-01

    The majority of children under the age of 5 appear to show spontaneous enjoyment of singing, being exposed to music and interacting with musical instruments, but whether variations in engaging in such activities in the home could contribute to developmental outcomes is still largely unknown. Critically, researchers lack a comprehensive instrument with good psychometric properties to assess the home musical environment from infancy to the preschool years. To address this gap, this paper presents two studies that describe the development and validation of the Music@Home questionnaire, which comprises two versions: Infant and Preschool. In Study 1, an initial pool of items was generated and administered to a wide audience of parents (n = 287 for the Infant, n = 347 for the Preschool version). Exploratory factor analysis was used to identify different dimensions comprising the home musical environment of both infants and pre-schoolers, and to reduce the initial pool of items to a smaller number of meaningful items. In Study 2, convergent and divergent validity and internal and test-retest reliability of the new instrument were established, using data from a different sample of participants (n = 213 for the Infant, n = 213 for the Preschool version). The second study also investigated associations between the Music@Home and musical characteristics of the parents, such as their musical education and personal engagement with music. Overall, the Music@Home constitutes a novel, valid and reliable instrument that allows for the systematic assessment of distinct aspects of the home musical environment in families with children under the age of 5. Furthermore, the Infant and Preschool versions of the Music@Home present differential associations with musical characteristics of the parents opening a new area of inquiry into how musical exposure and interaction in the home may vary across different developmental stages. PMID:29641607

  10. RESPONSE OF NIGERIAN CASSAVA EXPANSION INITIATIVES TO CLIMATE CHANGES, ECONOMIC GROWTH AND SOME POLICY INSTRUMENT (1970-2012

    Directory of Open Access Journals (Sweden)

    Onwumere Joseph

    2013-10-01

    Full Text Available This study considered the limiting response of Nigeria cassava expansion initiative to climate changes, economic growth and some policy instruments. The presidential initiative to make cassava a foreign exchange earner as well as ensuring that national demand are satisfied has made cassava a significant economic crop and resource input of industrial and international status. Currently, its derivatives such as animal feed, starch, ethanol, cassava chip, cassava flour, cassava liquor etc are in high demand. Having gained international recognition some factors need be examined to ascertain the limiting response of this economic crop some exogenous factors. The specific objectives of interest were to ascertain the response of cassava output expansion to rainfall, temperature, imports, exports, credit allocation to agribusiness, exchange rate, nominal interest rate, inflation and GDP from 1970 – 2012. Also, it examined the short and long run effects of these variables to cassava output so as to know how much adjustment it makes to reach the equilibrium. Secondary data were used for this research work. The technique of data analysis was auto- regressive modeling regression. To capture the long run and short run dynamics of cassava output behavior, the error correction model (ECM using the Engle-Granger methodology was adopted. The result revealed a very high rate of adjustment to long run equilibrium and the variables are correlated which means that impact of each variable on cassava output behavior in the economy is inseparable. The Error correction coefficient of -0.975 measures the speed of adjustment towards long run equilibrium earned the expected negative sign and is statistically significant at 1% risk level. Thus, this study recommends that the emerging cassava economy of Nigeria would be adequately empowered for efficient productivity if the Government stipulate policies that will encourage domestic output expansion to meet the national and

  11. Instrumental neutron activation analysis of iron and zinc in compact cosmetic products

    International Nuclear Information System (INIS)

    Kanias, G.D.

    1987-01-01

    An instrumental neutron activation analysis method is described for the determination of iron and zinc in compact eye shadow, compact face powder and compact rouge make-up cosmetic products. The steps of the procedure are: Irradiation of samples with thermal neutrons, counting of gamma-radioactivity of the radioisotopes of iron and zinc produced by this irradiation and calculation of the concentration of these elements from the gamma-ray spectra of samples and standards. Analysis of the I.A.E.A. standard reference material by this procedure give results in close agreement with certified values. The limit of quantitation is 45 μg for iron and 0.35 μg for zinc. The developed procedure could possibly be established as an official method for the simultaneous determination of iron and zinc in compact cosmetic products. (orig.) [de

  12. Simultaneous control of multiple instruments at the Advanced Technology Solar Telescope

    Science.gov (United States)

    Johansson, Erik M.; Goodrich, Bret

    2012-09-01

    The Advanced Technology Solar Telescope (ATST) is a 4-meter solar observatory under construction at Haleakala, Hawaii. The simultaneous use of multiple instruments is one of the unique capabilities that makes the ATST a premier ground based solar observatory. Control of the instrument suite is accomplished by the Instrument Control System (ICS), a layer of software between the Observatory Control System (OCS) and the instruments. The ICS presents a single narrow interface to the OCS and provides a standard interface for the instruments to be controlled. It is built upon the ATST Common Services Framework (CSF), an infrastructure for the implementation of a distributed control system. The ICS responds to OCS commands and events, coordinating and distributing them to the various instruments while monitoring their progress and reporting the status back to the OCS. The ICS requires no specific knowledge about the instruments. All information about the instruments used in an experiment is passed by the OCS to the ICS, which extracts and forwards the parameters to the appropriate instrument controllers. The instruments participating in an experiment define the active instrument set. A subset of those instruments must complete their observing activities in order for the experiment to be considered complete and are referred to as the must-complete instrument set. In addition, instruments may participate in eavesdrop mode, outside of the control of the ICS. All instrument controllers use the same standard narrow interface, which allows new instruments to be added without having to modify the interface or any existing instrument controllers.

  13. Formation Flying and Deformable Instruments

    International Nuclear Information System (INIS)

    Rio, Yvon

    2009-01-01

    Astronomers have always attempted to build very stable instruments. They fight all that can cause mechanical deformation or image motion. This has led to well established technologies (autoguide, active optics, thermal control, tip/tilt correction), as well as observing methods based on the use of controlled motion (scanning, micro scanning, shift and add, chopping and nodding). Formation flying disturbs this practice. It is neither possible to reduce the relative motion to very small amplitudes, nor to control it at will. Some impacts on Simbol-X instrument design, and operation are presented.

  14. Formation Flying and Deformable Instruments

    Science.gov (United States)

    Rio, Yvon

    2009-05-01

    Astronomers have always attempted to build very stable instruments. They fight all that can cause mechanical deformation or image motion. This has led to well established technologies (autoguide, active optics, thermal control, tip/tilt correction), as well as observing methods based on the use of controlled motion (scanning, micro scanning, shift and add, chopping and nodding). Formation flying disturbs this practice. It is neither possible to reduce the relative motion to very small amplitudes, nor to control it at will. Some impacts on Simbol-X instrument design, and operation are presented.

  15. Neutron beam instruments at Harwell

    International Nuclear Information System (INIS)

    Baston, A.H.; Harris, D.H.C.

    1978-11-01

    A list and brief descriptions are given of the neutron beam facilities for U.K. scientists at Harwell and in academic institutions, available under an agreement between the Science Research Council and AERE (Harwell). The list falls under the following headings: reactor instruments (single crystal diffractometers, powder diffractometers, triple axis spectrometers, time-of-flight cold neutron twin rotor spectrometer, beryllium filter spectrometer, MARX spectrometer, Harwell small-angle scattering spectrometer); LINAC instruments (total scattering spectrometer, back scattering spectrometer, active sample spectrometer, inelastic rotor spectrometer, constant Q spectrometer); ancillary equipment (cryostats, superconducting magnets, electromagnets, furnaces). (U.K.)

  16. Safeguards instrumentation: past, present, future

    International Nuclear Information System (INIS)

    Higinbotham, W.A.

    1982-01-01

    Instruments are essential for accounting, for surveillance and for protection of nuclear materials. The development and application of such instrumentation is reviewed, with special attention to international safeguards applications. Active and passive nondestructive assay techniques are some 25 years of age. The important advances have been in learning how to use them effectively for specific applications, accompanied by major advances in radiation detectors, electronics, and, more recently, in mini-computers. The progress in seals has been disappointingly slow. Surveillance cameras have been widely used for many applications other than safeguards. The revolution in TV technology will have important implications. More sophisticated containment/surveillance equipment is being developed but has yet to be exploited. On the basis of this history, some expectations for instrumentation in the near future are presented

  17. Iron Quadrangle, Brazil. Elemental concentration determined by k0-instrumental neutron activation analysis. Part 2. Kale samples

    International Nuclear Information System (INIS)

    Menezes, M.A.B.C.; Palmieri, H.E.L.; Leonel, L.V.; Nalini, H.A.Jr.; Jacimovic, R.

    2006-01-01

    The objective of this study was to evaluate the influence of mining activity on elemental concentrations in kale grown around a mining area. Two sites studied are in the Iron Quadrangle, Minas Gerais, Brazil, considered one of the richest mineral-bearing regions in the world. One site is near mineral exploration activity and the other is an ecological area. A comparator site outside the Iron Quadrangle was also analyzed. This work focused on the determination of the elemental concentrations in kale applying the k 0 -instrumental neutron activation analysis. As the Brazilian legislation specifies values for soil only, the results for kale were compared to the literature values and it was found that the vegetable does not present any health risks. (author)

  18. Comparison Between Individually and Group-Based Insulin Pump Initiation by Time-Driven Activity-Based Costing.

    Science.gov (United States)

    Ridderstråle, Martin

    2017-07-01

    Depending on available resources, competencies, and pedagogic preference, initiation of insulin pump therapy can be performed on either an individual or a group basis. Here we compared the two models with respect to resources used. Time-driven activity-based costing (TDABC) was used to compare initiating insulin pump treatment in groups (GT) to individual treatment (IT). Activities and cost drivers were identified, timed, or estimated at location. Medical quality and patient satisfaction were assumed to be noninferior and were not measured. GT was about 30% less time-consuming and 17% less cost driving per patient and activity compared to IT. As a batch driver (16 patients in one group) GT produced an upward jigsaw-shaped accumulative cost curve compared to the incremental increase incurred by IT. Taking the alternate cost for those not attending into account, and realizing the cost of opportunity gained, suggested that GT was cost neutral already when 5 of 16 patients attended, and that a second group could be initiated at no additional cost as the attendance rate reached 15:1. We found TDABC to be effective in comparing treatment alternatives, improving cost control and decision making. Everything else being equal, if the setup is available, our data suggest that initiating insulin pump treatment in groups is far more cost effective than on an individual basis and that TDABC may be used to find the balance point.

  19. Initiation of DNA replication requires actin dynamics and formin activity.

    Science.gov (United States)

    Parisis, Nikolaos; Krasinska, Liliana; Harker, Bethany; Urbach, Serge; Rossignol, Michel; Camasses, Alain; Dewar, James; Morin, Nathalie; Fisher, Daniel

    2017-11-02

    Nuclear actin regulates transcriptional programmes in a manner dependent on its levels and polymerisation state. This dynamics is determined by the balance of nucleocytoplasmic shuttling, formin- and redox-dependent filament polymerisation. Here, using Xenopus egg extracts and human somatic cells, we show that actin dynamics and formins are essential for DNA replication. In proliferating cells, formin inhibition abolishes nuclear transport and initiation of DNA replication, as well as general transcription. In replicating nuclei from transcriptionally silent Xenopus egg extracts, we identified numerous actin regulators, and disruption of actin dynamics abrogates nuclear transport, preventing NLS (nuclear localisation signal)-cargo release from RanGTP-importin complexes. Nuclear formin activity is further required to promote loading of cyclin-dependent kinase (CDK) and proliferating cell nuclear antigen (PCNA) onto chromatin, as well as initiation and elongation of DNA replication. Therefore, actin dynamics and formins control DNA replication by multiple direct and indirect mechanisms. © 2017 The Authors.

  20. Elemental analysis using instrumental neutron activation analysis and inductively coupled plasma atomic emission spectrometry: a comparative study

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Choi, Kwang Soon; Moon, Jong Hwa; Kim, Sun Ha; Lim, Jong Myoung; Kim, Young Jin; Quraishi, Shamshad Begum

    2003-05-01

    Elemental analyses for certified reference materials were carried out using instrumental neutron activation analysis and inductively coupled plasma-atomic emission spectrometry. Five Certified Reference Materials (CRM) were selected for the study on comparative analysis of environmental samples. The CRM are Soil (NIST SRM 2709), Coal fly ash (NIST SRM 1633a), urban dust (NIST SRM 1649a) and air particulate on filter media (NIST SRM 2783 and human hair (GBW 09101)

  1. International economic association on production of nuclear instrumentation - ''INTERINSTRUMENT''

    International Nuclear Information System (INIS)

    Twardon, Z.

    1979-01-01

    History of establishment and development of the International economic association ''Interinstrument'' is stated. Structure of the Association is given and directions of its activity, as well as structure of its budget. List is given of organizations, performing works according to the agreements with the Association. Main directions are stated of activity of the Association in the field of specialization of production of items of nuclear equipment; co-ordination of activity in the sphere of foreign trade; information about new instruments. Activity is stated of the branch offices of the Association, engaged in maintenance of instruments and nuclear equipment [ru

  2. Regulatory requirements on the calibration and use of survey instruments

    International Nuclear Information System (INIS)

    Domondon, D.B.

    1989-01-01

    Regulatory requirements on the provision, calibration and occasions of use of survey instruments are enumerated for a number of licensed activities. Two methods of calibrating survey instruments are described. Factors that must be taken into consideration in conducting calibrations, contents of calibration reports and of the sticker attached to the instrument which are needed for the correct use of the instrument are discussed. The precautions to be observed in order to insure correct use of survey instruments are described. (Auth.)

  3. Matriptase activation connects tissue factor-dependent coagulation initiation to epithelial proteolysis and signaling.

    Science.gov (United States)

    Le Gall, Sylvain M; Szabo, Roman; Lee, Melody; Kirchhofer, Daniel; Craik, Charles S; Bugge, Thomas H; Camerer, Eric

    2016-06-23

    The coagulation cascade is designed to sense tissue injury by physical separation of the membrane-anchored cofactor tissue factor (TF) from inactive precursors of coagulation proteases circulating in plasma. Once TF on epithelial and other extravascular cells is exposed to plasma, sequential activation of coagulation proteases coordinates hemostasis and contributes to host defense and tissue repair. Membrane-anchored serine proteases (MASPs) play critical roles in the development and homeostasis of epithelial barrier tissues; how MASPs are activated in mature epithelia is unknown. We here report that proteases of the extrinsic pathway of blood coagulation transactivate the MASP matriptase, thus connecting coagulation initiation to epithelial proteolysis and signaling. Exposure of TF-expressing cells to factors (F) VIIa and Xa triggered the conversion of latent pro-matriptase to an active protease, which in turn cleaved the pericellular substrates protease-activated receptor-2 (PAR2) and pro-urokinase. An activation pathway-selective PAR2 mutant resistant to direct cleavage by TF:FVIIa and FXa was activated by these proteases when cells co-expressed pro-matriptase, and matriptase transactivation was necessary for efficient cleavage and activation of wild-type PAR2 by physiological concentrations of TF:FVIIa and FXa. The coagulation initiation complex induced rapid and prolonged enhancement of the barrier function of epithelial monolayers that was dependent on matriptase transactivation and PAR2 signaling. These observations suggest that the coagulation cascade engages matriptase to help coordinate epithelial defense and repair programs after injury or infection, and that matriptase may contribute to TF-driven pathogenesis in cancer and inflammation.

  4. Rotor instrumentation circuits for the Sandia 34-meter vertical axis wind turbine

    Science.gov (United States)

    Sutherland, Herbert J.; Stephenson, William A.

    1988-07-01

    Sandia National Laboratories has erected a research oriented, 34-meter diameter, Darrieus vertical axis wind turbine near Bushland, Texas, which has been designated the Sandia 34-m VAWT Test Bed. To meet present and future research needs, the machine was equipped with a large array of sensors. This manuscript details the sensors initially placed on the rotor, their respective instrumentation circuits, and the provisions incorporated into the design of the rotor instrumentation circuits for future research. This manuscript was written as a reference manual for the rotor instrumentation of the Test Bed.

  5. Enhancing excitability of dopamine neurons promotes motivational behaviour through increased action initiation.

    Science.gov (United States)

    Boekhoudt, Linde; Wijbrans, Ellen C; Man, Jodie H K; Luijendijk, Mieneke C M; de Jong, Johannes W; van der Plasse, Geoffrey; Vanderschuren, Louk J M J; Adan, Roger A H

    2018-01-01

    Motivational deficits are a key symptom in multiple psychiatric disorders, including major depressive disorder, schizophrenia and addiction. A likely neural substrate for these motivational deficits is the brain dopamine (DA) system. In particular, DA signalling in the nucleus accumbens, which originates from DA neurons in the ventral tegmental area (VTA), has been identified as a crucial substrate for effort-related and activational aspects of motivation. Unravelling how VTA DA neuronal activity relates to motivational behaviours is required to understand how motivational deficits in psychiatry can be specifically targeted. In this study, we therefore used designer receptors exclusively activated by designer drugs (DREADD) in TH:Cre rats, in order to determine the effects of chemogenetic DA neuron activation on different aspects of motivational behaviour. We found that chemogenetic activation of DA neurons in the VTA, but not substantia nigra, significantly increased responding for sucrose under a progressive ratio schedule of reinforcement. More specifically, high effort exertion was characterized by increased initiations of reward-seeking actions. This effect was dependent on effort requirements and instrumental contingencies, but was not affected by sucrose pre-feeding. Together, these findings indicate that VTA DA neuronal activation drives motivational behaviour by facilitating action initiation. With this study, we show that enhancing excitability of VTA DA neurons is a viable strategy to improve motivational behaviour. Copyright © 2017 Elsevier B.V. and ECNP. All rights reserved.

  6. Ideology as instrument.

    Science.gov (United States)

    Glassman, Michael; Karno, Donna

    2007-12-01

    Comments on the article by J. T. Jost, which argued that the end-of-ideology claims that emerged in the aftermath of World War II were both incorrect and detrimental to the field of political psychology. M. Glassman and D. Karno make three critical points. First, Jost objectified ideology as a grand strategy implemented at the individual level, rather than as an instrument used for a specific purpose in activity. In doing so, he set ideology up as an "object" that guides human behavior rather than as a rational part of human experience. Second, they take issue with the idea that, because somebody acts in a manner that can be categorized as ideological, there actually is such a thing as ideology separate from that event and/or political experience and that psychologists ought to understand the meaning of ideology in order to understand future human activities as outside observers. Third, Jost seems to see this objective ideology as a unidirectional, causal mechanism for activity, a mechanism that assumes individuals act according to ideology, which eclipses the possibility that immediate ideological positions are the residue of purposeful activity. Glassman and Karno suggest that it may be better to take a pluralistic view of ideology in human action. Where ideology does exist, it is as a purposeful instrument--part of a logically based action to meet some ends-in-view--a mixture of immediate goals tied to secondary belief systems (which have been integrated to serve the material purposes of the purveyors of these ideologies). So if we are to understand ideology, we can only understand it through its use in human activity. (Copyright) 2007 APA.

  7. Extrinsic Motivators Affecting Fourth-Grade Students' Interest and Enrollment in an Instrumental Music Program

    Science.gov (United States)

    Vasil, Martina

    2013-01-01

    The purpose of this study was to investigate fourth-grade students' extrinsic motivators for joining and continuing in a school instrumental music program. Three research questions were investigated: (a) What extrinsic motivators have influenced fourth-grade students' initial interest and continuing participation in an instrumental music program?…

  8. Mild cognitive impairment and deficits in instrumental activities of daily living: a systematic review.

    Science.gov (United States)

    Jekel, Katrin; Damian, Marinella; Wattmo, Carina; Hausner, Lucrezia; Bullock, Roger; Connelly, Peter J; Dubois, Bruno; Eriksdotter, Maria; Ewers, Michael; Graessel, Elmar; Kramberger, Milica G; Law, Emma; Mecocci, Patrizia; Molinuevo, José L; Nygård, Louise; Olde-Rikkert, Marcel Gm; Orgogozo, Jean-Marc; Pasquier, Florence; Peres, Karine; Salmon, Eric; Sikkes, Sietske Am; Sobow, Tomasz; Spiegel, René; Tsolaki, Magda; Winblad, Bengt; Frölich, Lutz

    2015-01-01

    There is a growing body of evidence that subtle deficits in instrumental activities of daily living (IADL) may be present in mild cognitive impairment (MCI). However, it is not clear if there are IADL domains that are consistently affected across patients with MCI. In this systematic review, therefore, we aimed to summarize research results regarding the performance of MCI patients in specific IADL (sub)domains compared with persons who are cognitively normal and/or patients with dementia. The databases PsycINFO, PubMed and Web of Science were searched for relevant literature in December 2013. Publications from 1999 onward were considered for inclusion. Altogether, 497 articles were retrieved. Reference lists of selected articles were searched for potentially relevant articles. After screening the abstracts of these 497 articles, 37 articles were included in this review. In 35 studies, IADL deficits (such as problems with medication intake, telephone use, keeping appointments, finding things at home and using everyday technology) were documented in patients with MCI. Financial capacity in patients with MCI was affected in the majority of studies. Effect sizes for group differences between patients with MCI and healthy controls were predominantly moderate to large. Performance-based instruments showed slight advantages (in terms of effect sizes) in detecting group differences in IADL functioning between patients with MCI, patients with Alzheimer's disease and healthy controls. IADL requiring higher neuropsychological functioning seem to be most severely affected in patients with MCI. A reliable identification of such deficits is necessary, as patients with MCI with IADL deficits seem to have a higher risk of converting to dementia than patients with MCI without IADL deficits. The use of assessment tools specifically designed and validated for patients with MCI is therefore strongly recommended. Furthermore, the development of performance-based assessment instruments

  9. Comparison of elemental contents of Korean space foods using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Yong Sam Chung; Sun Ha Kim; Gwang Min Sun; Jong Myoung Lim; Jong Hwa Moon; Kye Hong Lee; Young Jin Kim; Jong Il Choi; Ju Woon Lee

    2012-01-01

    The analysis of mineral contents in space foods is needed to obtain an information on a comprehensive elemental composition as well as the investigation on the effects of human nutrition and health based on the dietary intake of mineral elements. Recently, six items of new Korean space foods (KSFs) such as kimchi, bibimbap, bulgogi, a ramen, a mulberry beverage and a fruit punch which was developed by the KAERI, and the contents of more than 15 elements in the samples were examined by using instrumental neutron activation analysis (INAA). Five biological certified reference materials, NIST SRM were used for analytical quality control. The results were compared with those of common Korean foods reported, and these results will be applied toward the identification of irradiated foods. (author)

  10. Trace element determination in beauty products by k0-instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Sneyers, L.; Verheyen, L.; Vermaercke, P.; Bruggeman, M.

    2009-01-01

    A recent study on trace elements in beauty products and cosmetics sold on the Asian market has shown the presence of high levels of U, Th and rare earth elements in so called 'Hormesis cosmetics'. For the purpose of comparison, some more information about trace elements in European cosmetics would be useful. In this paper the results obtained using k 0 -standardised Instrumental Neutron Activation Analysis (k 0 -INAA) for more than 20 trace elements in 20 different beauty products collected from the European market are presented. We found traces of Ba, As and Sb which is in breach with European legislation. For some of the other elements like Cr and Co further speciation is needed in order to evaluate their presence in beauty products. (author)

  11. Characterization of Brazilian commercial milks by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Santos, L.G.C.; De Nadai Fernandes, E.A.; Tagliaferro, F.S.; Bacchi, M.A.

    2008-01-01

    Aiming at the determination of toxic and essential elements in Brazilian commercial bovine milk, 25 ultra high temperature (UHT) milk samples were acquired in the local market of Piracicaba, SP. The samples were freeze-dried and analyzed by instrumental neutron activation analysis (INAA) allowing the determination of Br, Ca, Co, Cs, Fe, K, Na, Rb and Zn. When the results were expressed as concentration (mg x l -1 ) no significant differences were found. However, considering the dry matter, results showed a clear difference between the mass fractions (mg x kg -1 d.w.) of skim milk and whole milk for the elements Br, Ca, K, Na, Rb and Zn, indicating that the removal of fat caused a concentration effect in the dry matter of skim milks. Discrepancies were found between the concentrations of Ca and Na measured by INAA and the values informed in the labels. Ca showed variations within 30% for most samples, while concentrations of Na were up to 190% higher than informed values. The sample preparation and the INAA procedure were appropriate for the determination of Br, Ca, Co, Cs, Fe, K, Na, Rb and Zn in milk samples. (author)

  12. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  13. The DnaA Cycle in Escherichia coli: Activation, Function and Inactivation of the Initiator Protein

    Directory of Open Access Journals (Sweden)

    Tsutomu Katayama

    2017-12-01

    Full Text Available This review summarizes the mechanisms of the initiator protein DnaA in replication initiation and its regulation in Escherichia coli. The chromosomal origin (oriC DNA is unwound by the replication initiation complex to allow loading of DnaB helicases and replisome formation. The initiation complex consists of the DnaA protein, DnaA-initiator-associating protein DiaA, integration host factor (IHF, and oriC, which contains a duplex-unwinding element (DUE and a DnaA-oligomerization region (DOR containing DnaA-binding sites (DnaA boxes and a single IHF-binding site that induces sharp DNA bending. DiaA binds to DnaA and stimulates DnaA assembly at the DOR. DnaA binds tightly to ATP and ADP. ATP-DnaA constructs functionally different sub-complexes at DOR, and the DUE-proximal DnaA sub-complex contains IHF and promotes DUE unwinding. The first part of this review presents the structures and mechanisms of oriC-DnaA complexes involved in the regulation of replication initiation. During the cell cycle, the level of ATP-DnaA level, the active form for initiation, is strictly regulated by multiple systems, resulting in timely replication initiation. After initiation, regulatory inactivation of DnaA (RIDA intervenes to reduce ATP-DnaA level by hydrolyzing the DnaA-bound ATP to ADP to yield ADP-DnaA, the inactive form. RIDA involves the binding of the DNA polymerase clamp on newly synthesized DNA to the DnaA-inactivator Hda protein. In datA-dependent DnaA-ATP hydrolysis (DDAH, binding of IHF at the chromosomal locus datA, which contains a cluster of DnaA boxes, results in further hydrolysis of DnaA-bound ATP. SeqA protein inhibits untimely initiation at oriC by binding to newly synthesized oriC DNA and represses dnaA transcription in a cell cycle dependent manner. To reinitiate DNA replication, ADP-DnaA forms oligomers at DnaA-reactivating sequences (DARS1 and DARS2, resulting in the dissociation of ADP and the release of nucleotide-free apo-DnaA, which then

  14. Cosmetics chemical composition characterization by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Ana Paula; Pereira, Gustavo Jose; Amaral, Angela Maria; Ferreira, Andrea Vidal, E-mail: ana_allves2008@hotmail.co [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2009-07-01

    Brazil is in the third position in the world's cosmetics market. It is an expanding and growing market where new products and manufacturing processes are in a constant and steady expansion. Therefore, it is mandatory that the composition of the products is well known in order to guarantee safety and quality of daily used cosmetics. The Brazilian National Health Surveillance Agency (ANVISA) has issued a resolution, RDC No. 48, March 16, 2006, which defines a 'List of Substances which can not be used in personal hygiene products, cosmetics and perfumes'. In this work, samples of locally manufactured and imported cosmetics (lipsticks, eye shadows, etc.) were analyzed using the Instrumental Neutron Activation Analysis technique. The samples were irradiated in the TRIGA IPR-R1 reactor of the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN), on a 100kW thermal power, with a thermal neutron fluence rate about 8x10{sup 11}ncm{sup -2}s{sup -1}. The analysis has detected the chemical elements Br, Ba, Ga, Na, K, Sc, Fe, Cr, Zn, Sm, W, La, Rb, Cs, Ta, Ge, Co, U, Ti, V, Cl, Al, Mn and Cu. The concentrations of these elements are on a range from 5 to 3000mug.g{sup -1}. Some chemical elements observed in samples (Cl, Br, Cr, U) are included at ANVISA prohibitive list. (author)

  15. Cosmetics chemical composition characterization by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Alves, Ana Paula; Pereira, Gustavo Jose; Amaral, Angela Maria; Ferreira, Andrea Vidal

    2009-01-01

    Brazil is in the third position in the world's cosmetics market. It is an expanding and growing market where new products and manufacturing processes are in a constant and steady expansion. Therefore, it is mandatory that the composition of the products is well known in order to guarantee safety and quality of daily used cosmetics. The Brazilian National Health Surveillance Agency (ANVISA) has issued a resolution, RDC No. 48, March 16, 2006, which defines a 'List of Substances which can not be used in personal hygiene products, cosmetics and perfumes'. In this work, samples of locally manufactured and imported cosmetics (lipsticks, eye shadows, etc.) were analyzed using the Instrumental Neutron Activation Analysis technique. The samples were irradiated in the TRIGA IPR-R1 reactor of the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN), on a 100kW thermal power, with a thermal neutron fluence rate about 8x10 11 ncm -2 s -1 . The analysis has detected the chemical elements Br, Ba, Ga, Na, K, Sc, Fe, Cr, Zn, Sm, W, La, Rb, Cs, Ta, Ge, Co, U, Ti, V, Cl, Al, Mn and Cu. The concentrations of these elements are on a range from 5 to 3000μg.g -1 . Some chemical elements observed in samples (Cl, Br, Cr, U) are included at ANVISA prohibitive list. (author)

  16. Utilizing Social Media to Further the Nationwide Suspicious Activity Reporting Initiative

    Science.gov (United States)

    2012-09-01

    Initiative NYPD New York Police Department OSINT Open Source Intelligence P2P Peer to Patent SAR Suspicious Activity Report SMS Short Message (or...Media as an Open-Source Intelligence Tool Several government documents outline the use of social media as an Open Source intelligence tool ( OSINT ...social media to be an OSINT tool that federal, state, and local law enforcement agencies should use to develop timely, relevant, and actionable

  17. MONTANA PALLADIUM RESEARCH INITIATIVE

    Energy Technology Data Exchange (ETDEWEB)

    Peters, John; McCloskey, Jay; Douglas, Trevor; Young, Mark; Snyder, Stuart; Gurney, Brian

    2012-05-09

    Project Objective: The overarching objective of the Montana Palladium Research Initiative is to perform scientific research on the properties and uses of palladium in the context of the U.S. Department of Energy's Hydrogen, Fuel Cells and Infrastructure Technologies Program. The purpose of the research will be to explore possible palladium as an alternative to platinum in hydrogen-economy applications. To achieve this objective, the Initiatives activities will focus on several cutting-edge research approaches across a range of disciplines, including metallurgy, biomimetics, instrumentation development, and systems analysis. Background: Platinum-group elements (PGEs) play significant roles in processing hydrogen, an element that shows high potential to address this need in the U.S. and the world for inexpensive, reliable, clean energy. Platinum, however, is a very expensive component of current and planned systems, so less-expensive alternatives that have similar physical properties are being sought. To this end, several tasks have been defined under the rubric of the Montana Palladium Research Iniative. This broad swath of activities will allow progress on several fronts. The membrane-related activities of Task 1 employs state-of-the-art and leading-edge technologies to develop new, ceramic-substrate metallic membranes for the production of high-purity hydrogen, and develop techniques for the production of thin, defect-free platinum group element catalytic membranes for energy production and pollution control. The biomimetic work in Task 2 explores the use of substrate-attached hydrogen-producing enzymes and the encapsulation of palladium in virion-based protein coats to determine their utility for distributed hydrogen production. Task 3 work involves developing laser-induced breakdown spectroscopy (LIBS) as a real-time, in situ diagnostic technique to characterize PGEs nanoparticles for process monitoring and control. The systems engineering work in task 4

  18. The cross-cultural equivalence of participation instruments: a systematic review.

    Science.gov (United States)

    Stevelink, S A M; van Brakel, W H

    2013-07-01

    be used to ensure comprehensive reporting of the validation (equivalence) testing process and its results. • Participation instruments are often used in a different cultural setting than initial developed for. • The conceptualization of participation may vary across cultures. Therefore, cultural equivalence – the extent to which an instrument is equally suitable for use in two or more cultures – is an important concept to address. • This review showed that the process of cultural equivalence testing of the included participation instruments was often addressed insufficiently. • Clinicians should be aware that application of participations instruments in a different culture than initially developed for needs prior testing of cultural validity in the next context.

  19. 2017 Marine Hydrokinetic Instrumentation Workshop Report

    Energy Technology Data Exchange (ETDEWEB)

    Driscoll, Frederick R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Mauer, Erik [U.S. Department of Energy; Rieks, Jeff [Allegheny Science and Technologies

    2018-03-06

    The third Marine Hydrokinetic Instrumentation Workshop was held at Florida Atlantic University's Sea Tech Campus in Dania Beach, Florida, from February 28 to March 1, 2017. The workshop brought together 37 experts in marine energy measurement, testing, and technology development to present and discuss the instrumentation and data-processing needs of the marine energy industry. The workshop was comprised of a plenary session followed by two focused breakout sessions. The half-day plenary session reviewed findings from prior instrumentation workshops, presented research activities that aim to fill previously identified gaps, and had industry experts present the state of the marine energy measurement technologies. This report provides further detail on the workshop, objectives, and findings.

  20. Cultural validation of a new instrument to measure leprosy-related stigma: the SARI Stigma Scale

    NARCIS (Netherlands)

    Dadun,; Peters, Ruth M. H.; Van Brakel, Wim H.; Lusli, Mimi; Damayanti, Rita; Irwanto, A.; Bunders- Aelen, J.G.F.

    Background: There is a need for comprehensive, valid and reliable instruments to assess leprosy-related stigma. This paper presents the process of the cross-cultural validation of an instrument in Cirebon District, Indonesia initiated by the Stigma Assessment and Reduction of Impact (SARI) project.

  1. A Community-Level Initiative to Prevent Obesity: Results From Kaiser Permanente's Healthy Eating Active Living Zones Initiative in California.

    Science.gov (United States)

    Cheadle, Allen; Atiedu, Akpene; Rauzon, Suzanne; Schwartz, Pamela M; Keene, Laura; Davoudi, Mehrnaz; Spring, Rebecca; Molina, Michelle; Lee, Lynda; Boyle, Kathryn; Williamson, Dana; Steimberg, Clara; Tinajero, Roberta; Ravel, Jodi; Nudelman, Jean; Azuma, Andrea Misako; Kuo, Elena S; Solomon, Loel

    2018-05-01

    A growing number of health systems are leading health promotion efforts in their wider communities. What impact are these efforts having on health behaviors and ultimately health status? This paper presents evaluation results from the place-based Kaiser Permanente Healthy Eating Active Living Zones obesity prevention initiative, implemented in 2011-2015 in 12 low-income communities in Kaiser Permanente's Northern and Southern California Regions. The Healthy Eating Active Living Zones design targeted places and people through policy, environmental, and programmatic strategies. Each Healthy Eating Active Living Zone is a small, low-income community of 10,000 to 20,000 residents with high obesity rates and other health disparities. Community coalitions planned and implemented strategies in each community. A population-dose approach and pre and post surveys were used to assess impact of policy, program, and environmental change strategies; the analysis was conducted in 2016. Population dose is the product of reach (number of people affected by a strategy divided by target population size) and strength (the effect size or relative change in behavior for each person exposed to the strategy). More than 230 community change strategies were implemented over 3 years, encompassing policy, environmental, and programmatic changes as well as efforts to build community capacity to sustain strategies and make changes in the future. Positive population-level results were seen for higher-dose strategies, particularly those targeting youth physical activity. Higher-dose strategies were more likely to be found in communities with the longest duration of investment. These results demonstrate that strong (high-dose), community-based obesity prevention strategies can lead to improved health behaviors, particularly among youth in school settings. This article is part of a supplement entitled Building Thriving Communities Through Comprehensive Community Health Initiatives, which is

  2. Evaluation of the Primary Care in leprosy control: proposal of an instrument for users

    Directory of Open Access Journals (Sweden)

    Fernanda Moura Lanza

    2014-12-01

    Full Text Available Objective Developing an instrument to evaluate the performance of primary health care in the leprosy control actions, from the perspective of users and do the face and content validation. Method This is a methodological study carried out in four stages: development of instrument, face and content validation, pre-test, and analysis of test-retest reliability. Results The initial instrument submitted to the judgment of 15 experts was composed of 157 items. The face and content validation and pre-test of instrument were essential for the exclusion of items and adjustment of instrument to evaluate the object under study. In the analysis of test-retest reliability, the instrument proved to be reliable. Conclusion The instrument is considered adequate, but further studies are needed to test the psychometric properties.

  3. Elementary composition of the siderurgy slag by instrumental neutron activation analysis; Composicao elementar em escoria de siderurgia por analise por ativacao neutronica instrumental

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Helder de; Piau, Wilson Caixeta; Mortatti, Jefferson [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil); Sarries, Gabriel Adrian [Sao Paulo Univ., Piracicaba, SP (Brazil). Escola Superior de Agricultura Luiz de Queiroz

    2000-07-01

    The slag has been applied to the ground to neutralize its acidity, in similar way to the calcareous rock, contributing in the agriculture as corrective of the acidity alone it and source of nutrients for the plants. However, the alternative for the agricultural slag exploitation is related to metal texts heavy gifts in the slag. The objective of the present work was to survey of the chemical composition of trashes generated in blast high-oven, steel, oven of pan and fertilizers that had used in its manufacture slag of siderurgy for the technique of instrumental neutron activation analysis. The results had evidenced the existence of high variations in the elements Ce, Cr, In, K, Sb and Zn in the distinct analyzed samples. (author)

  4. The PROactive innovative conceptual framework on physical activity.

    Science.gov (United States)

    Dobbels, Fabienne; de Jong, Corina; Drost, Ellen; Elberse, Janneke; Feridou, Chryssoula; Jacobs, Laura; Rabinovich, Roberto; Frei, Anja; Puhan, Milo A; de Boer, Willem I; van der Molen, Thys; Williams, Kate; Pinnock, Hillary; Troosters, Thierry; Karlsson, Niklas; Kulich, Karoly; Rüdell, Katja

    2014-11-01

    Although physical activity is considered an important therapeutic target in chronic obstructive pulmonary disease (COPD), what "physical activity" means to COPD patients and how their perspective is best measured is poorly understood. We designed a conceptual framework, guiding the development and content validation of two patient reported outcome (PRO) instruments on physical activity (PROactive PRO instruments). 116 patients from four European countries with diverse demographics and COPD phenotypes participated in three consecutive qualitative studies (63% male, age mean±sd 66±9 years, 35% Global Initiative for Chronic Obstructive Lung Disease stage III-IV). 23 interviews and eight focus groups (n = 54) identified the main themes and candidate items of the framework. 39 cognitive debriefings allowed the clarity of the items and instructions to be optimised. Three themes emerged, i.e. impact of COPD on amount of physical activity, symptoms experienced during physical activity, and adaptations made to facilitate physical activity. The themes were similar irrespective of country, demographic or disease characteristics. Iterative rounds of appraisal and refinement of candidate items resulted in 30 items with a daily recall period and 34 items with a 7-day recall period. For the first time, our approach provides comprehensive insight on physical activity from the COPD patients' perspective. The PROactive PRO instruments' content validity represents the pivotal basis for empirically based item reduction and validation. ©ERS 2014.

  5. Instrument comparison for Aerosolized Titanium Dioxide

    Science.gov (United States)

    Ranpara, Anand

    Recent toxicological studies have shown that the surface area of ultrafine particles (UFP i.e., particles with diameters less than 0.1 micrometer) has a stronger correlation with adverse health effects than does mass of these particles. Ultrafine titanium dioxide (TiO2) particles are widely used in industry, and their use is associated with adverse health outcomes, such as micro vascular dysfunctions and pulmonary damages. The primary aim of this experimental study was to compare a variety of laboratory and industrial hygiene (IH) field study instruments all measuring the same aerosolized TiO2. The study also observed intra-instrument variability between measurements made by two apparently identical devices of the same type of instrument placed side-by-side. The types of instruments studied were (1) DustTrak(TM) DRX, (2) Personal Data RAMs(TM) (PDR), (3) GRIMM, (4) Diffusion charger (DC) and (5) Scanning Mobility Particle Sizer (SMPS). Two devices of each of the four IH field study instrument types were used to measure six levels of mass concentration of fine and ultrafine TiO2 aerosols in controlled chamber tests. Metrics evaluated included real-time mass, active surface area and number/geometric surface area distributions, and off-line gravimetric mass and morphology on filters. DustTrak(TM) DRXs and PDRs were used for mass concentration measurements. DCs were used for active surface area concentration measurements. GRIMMs were used for number concentration measurements. SMPS was used for inter-instrument comparisons of surface area and number concentrations. The results indicated that two apparently identical devices of each DRX and PDR were statistically not different with each other for all the trials of both the sizes of powder (p < 5%). Mean difference between mass concentrations measured by two DustTrak DRX devices was smaller than that measured by two PDR devices. DustTrak DRX measurements were closer to the reference method, gravimetric mass concentration

  6. Increase in Social Activity of Citizens on the Basis of Grant Support of Rural Initiatives

    Directory of Open Access Journals (Sweden)

    Bogatchev Alexander I.

    2016-11-01

    Full Text Available The article is devoted to the problems of development of social activity of population. The low activity of local population is now characterized by the following social trends: aloofness from public life, individualism, leading-strings mentality, consumer attitude, legal nihilism. The characteristic of the main reasons for the current situation is given in the article. It is noted that one of the effective tools to attract social investment and development is a grant support for local initiatives, which plays an important role in increasing the social activity of population. This article focuses on the development of grant support in the rural areas at the modern stage. The author analyzed the current status of grant support of rural initiatives in Russia and the Orel region. It is noted that the grant support has great potential, although it is at an early stage of its development. In the conclusion, actions for the development of social activity at the local level are planned.

  7. Possibilities of instrumental neutron activation and X-ray fluorescence analyses of sedimentary-magmatic metamorphosed rocks from deep borehole drill cores

    International Nuclear Information System (INIS)

    Gurevich, A.L.; Drynkin, V.I.; Lejpunskaya, D.I.

    1977-01-01

    The possibilities for instrumental neutron-activation and X-ray fluorescence analyses of rocks of metamorphized sedimentary magmatic complexes have been studied with the aid of deep-hole core. The principal characteristics of the conditions of irradiation and of sample measurement ensuring the determination of the content of 26 elements are presented. The use of X-ray fluorescence analysis enables one to determine additionally the content of stron-tium and niobium. Standard specimens of the composition of rocks and complex reference compounds based on phenol formaldehyde resins are used as metrolo.o.ical auxiliaries in the calibration system and in evaluating the correctness of the techniques of instrumental neutron activation and fluorescence analysis. The ranges of the contents to be determined, the sensitivity and relative standard deviation are given. The contribution from the nonuniformity of the specimens to the summary error of element determination is estimated. It is shown that the accuracy and error of analyses are within the allowable range

  8. Validity and reliability of a Malay version of the Lawton instrumental activities of daily living scale among the Malay speaking elderly in Malaysia.

    Science.gov (United States)

    Kadar, Masne; Ibrahim, Suhaili; Razaob, Nor Afifi; Chai, Siaw Chui; Harun, Dzalani

    2018-02-01

    The Lawton Instrumental Activities of Daily Living Scale is a tool often used to assess independence among elderly at home. Its suitability to be used with the elderly population in Malaysia has not been validated. This current study aimed to assess the validity and reliability of the Lawton Instrumental Activities of Daily Living Scale - Malay Version to Malay speaking elderly in Malaysia. This study was divided into three phases: (1) translation and linguistic validity involving both forward and backward translations; (2) establishment of face validity and content validity; and (3) establishment of reliability involving inter-rater, test-retest and internal consistency analyses. Data used for these analyses were obtained by interviewing 65 elderly respondents. Percentages of Content Validity Index for 4 criteria were from 88.89 to 100.0. The Cronbach α coefficient for internal consistency was 0.838. Intra-class Correlation Coefficient of inter-rater reliability and test-retest reliability was 0.957 and 0.950 respectively. The result shows that the Lawton Instrumental Activities of Daily Living Scale - Malay Version has excellent reliability and validity for use with the Malay speaking elderly people in Malaysia. This scale could be used by professionals to assess functional ability of elderly who live independently in community. © 2018 Occupational Therapy Australia.

  9. Division XII / Commission 41 / Working Group Historical Instruments

    Science.gov (United States)

    Pigatto, Luisa; Il-Seong, Nha; Hamel, Jürgen; Johnson, Kevin; Kochhar, Rajesh K.; Nakamura, Tsuko; Orchiston, Wayne; Pettersen, Bjørn R.; Schechner, Sara J.; Yunli, Shi

    The Historical Instruments Working Group (WG-HI) and Commission 41 started planning an interdisciplinary conference titled Astronomy and its instruments before and after Galileo since January 2007. This conference, as an IYA2009 initiative, aims “to highlight mankind's path toward an improved knowledge of the sky using mathematical and mechanical tools as well as monuments and buildings, giving rise, in doing so, to scientific astronomy”. Commission 46 and Commission 55 also support this conference, to be held on the Isle of San Servolo, Venice (Italy), 27 September 3 October 2009. As a fact of history, it was in Venice that Galileo was advised and got material (glass) to make his telescope, and in Venice he presented an working instrument to Venetian Doge in August 1609. The conference is co-sponsored by IAU as a Joint Symposium with the INAF Astronomical Observatory of Padova, Italy.

  10. Modularized Parallel Neutron Instrument Simulation on the TeraGrid

    International Nuclear Information System (INIS)

    Chen, Meili; Cobb, John W.; Hagen, Mark E.; Miller, Stephen D.; Lynch, Vickie E.

    2007-01-01

    In order to build a bridge between the TeraGrid (TG), a national scale cyberinfrastructure resource, and neutron science, the Neutron Science TeraGrid Gateway (NSTG) is focused on introducing productive HPC usage to the neutron science community, primarily the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). Monte Carlo simulations are used as a powerful tool for instrument design and optimization at SNS. One of the successful efforts of a collaboration team composed of NSTG HPC experts and SNS instrument scientists is the development of a software facility named PSoNI, Parallelizing Simulations of Neutron Instruments. Parallelizing the traditional serial instrument simulation on TeraGrid resources, PSoNI quickly computes full instrument simulation at sufficient statistical levels in instrument de-sign. Upon SNS successful commissioning, to the end of 2007, three out of five commissioned instruments in SNS target station will be available for initial users. Advanced instrument study, proposal feasibility evaluation, and experiment planning are on the immediate schedule of SNS, which pose further requirements such as flexibility and high runtime efficiency on fast instrument simulation. PSoNI has been redesigned to meet the new challenges and a preliminary version is developed on TeraGrid. This paper explores the motivation and goals of the new design, and the improved software structure. Further, it describes the realized new features seen from MPI parallelized McStas running high resolution design simulations of the SEQUOIA and BSS instruments at SNS. A discussion regarding future work, which is targeted to do fast simulation for automated experiment adjustment and comparing models to data in analysis, is also presented

  11. Active action potential propagation but not initiation in thalamic interneuron dendrites

    Science.gov (United States)

    Casale, Amanda E.; McCormick, David A.

    2012-01-01

    Inhibitory interneurons of the dorsal lateral geniculate nucleus of the thalamus modulate the activity of thalamocortical cells in response to excitatory input through the release of inhibitory neurotransmitter from both axons and dendrites. The exact mechanisms by which release can occur from dendrites are, however, not well understood. Recent experiments using calcium imaging have suggested that Na/K based action potentials can evoke calcium transients in dendrites via local active conductances, making the back-propagating action potential a candidate for dendritic neurotransmitter release. In this study, we employed high temporal and spatial resolution voltage-sensitive dye imaging to assess the characteristics of dendritic voltage deflections in response to Na/K action potentials in interneurons of the mouse dorsal lateral geniculate nucleus. We found that trains or single action potentials elicited by somatic current injection or local synaptic stimulation led to action potentials that rapidly and actively back-propagated throughout the entire dendritic arbor and into the fine filiform dendritic appendages known to release GABAergic vesicles. Action potentials always appeared first in the soma or proximal dendrite in response to somatic current injection or local synaptic stimulation, and the rapid back-propagation into the dendritic arbor depended upon voltage-gated sodium and TEA-sensitive potassium channels. Our results indicate that thalamic interneuron dendrites integrate synaptic inputs that initiate action potentials, most likely in the axon initial segment, that then back-propagate with high-fidelity into the dendrites, resulting in a nearly synchronous release of GABA from both axonal and dendritic compartments. PMID:22171033

  12. Application of instrumental neutron activation analysis for the examination of oil pigments

    International Nuclear Information System (INIS)

    Chung, Y.S.; Kim, S.H.; Sun, G.M.; Lim, J.M.; Moon, J.H.; Kim, Y.J.; Lim, S.J.; Song, Y.N.; Kim, K.

    2011-01-01

    This study is to investigate the applicability of instrumental neutron activation analysis (INAA) as a non-destructive examination tool for the quantitative chemical composition analysis associated with authentication, restoration and conservation of art objects in the field of cultural heritage. The quantitative analysis of major, minor and trace elements in Rembrandt's registered oil pigments recently collected at the Korean market as one of the art objects was carried out using INAA facilities of the HANARO research reactor at the Korea Atomic Energy Research Institute in collaboration with the National Museum of Contemporary Art in Korea. Analytical quality control was implemented using NIST SRM 2709, certified reference materials and metal standards. The analytical results for seventeen characteristic elements of thirty-one measured elements were statistically treated to identify the characteristic correlations and patterns between color and source of oil pigment and similarity degree of constituents using a cluster and discriminate analysis. (orig.)

  13. Is there an association between temporomandibular disorders and playing a musical instrument? A review of literature

    NARCIS (Netherlands)

    Atallah, M.M.; Visscher, C.M.; van Selms, M.K.A.; Lobbezoo, F.

    2014-01-01

    Temporomandibular disorders (TMDs) have a multifactorial etiology. Among others, parafunctions and oral habits have been suggested as important initiating and perpetuating factors. Playing a musical instrument that loads the masticatory system, like wind instruments and the violin or viola, has been

  14. Critical evaluation of the determination of zirconium and hafnium by instrumental and radiochemical neutron activation analysis

    International Nuclear Information System (INIS)

    Burger, Mario; Kraehenbuehl, Urs

    1991-01-01

    Neutron activation analysis (instrument or radiochemical) is suitable for the determination of zirconium and hafnium in samples of geochemical origin only when sufficient attention is paid to inter-fering nuclides. The size of the necessary correction for INAA depends on the composition of the sample; this problem is discussed. The radio-chemical technique which is recommended involves separation of the samples, precipitations and anion-exchange separation. Results are given for various standard reference materials and for meteorites. (author). 12 refs.; 1 fig.; 9 tabs

  15. Study and development of an airborne instrument for collecting aerosols and for measuring radon 222 by its active deposition

    International Nuclear Information System (INIS)

    Filippi, Dominique

    2000-01-01

    The study and development of an airborne instrument designed to collect aerosols and measure radon 222 is detailed in this thesis. Having discussed the context of radon and introduced the methods of the measurement of radon 222 by its natural active deposition, the measurement of aerosols with the Sextant Avionique/LSCE dynamic iso-kinetic probe is quantified. These estimations of the efficiency of the probe were obtained during iso-axial simulations of the flow around the probe at different sub-sonic speeds, then by the calculation of trajectories of particles at the entrance to the probe for several debit coefficients. The effect of the attack angle is discussed along with the iso-kinetic criteria of pressure necessary for the functioning of this probe. To conclude this theoretical study, the author has estimated the deposits during aerosol transport in pipes. The instrument once constructed, (dubbed A VIRAD), is then itself presented, along with the technological aspects adopted for its use. The instrument was validated during an experimental aerial study STAAARTE 99. The measures obtained during these flights are presented in the conclusions. (author) [fr

  16. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    Energy Technology Data Exchange (ETDEWEB)

    Baumgartner, A. [Vienna Univ. of Technology, Atominstitut, Wien (Austria); Maringer, F.J.; Michai, P.; Kreuziger, M. [BEV-Federal Office of Metrology and Surveying, Wien (Austria)

    2006-07-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  17. Using XML and Java Technologies for Astronomical Instrument Control

    Science.gov (United States)

    Ames, Troy; Case, Lynne; Powers, Edward I. (Technical Monitor)

    2001-01-01

    Traditionally, instrument command and control systems have been highly specialized, consisting mostly of custom code that is difficult to develop, maintain, and extend. Such solutions are initially very costly and are inflexible to subsequent engineering change requests, increasing software maintenance costs. Instrument description is too tightly coupled with details of implementation. NASA Goddard Space Flight Center, under the Instrument Remote Control (IRC) project, is developing a general and highly extensible framework that applies to any kind of instrument that can be controlled by a computer. The software architecture combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML), a human readable and machine understandable way to describe structured data. A key aspect of the object-oriented architecture is that the software is driven by an instrument description, written using the Instrument Markup Language (IML), a dialect of XML. IML is used to describe the command sets and command formats of the instrument, communication mechanisms, format of the data coming from the instrument, and characteristics of the graphical user interface to control and monitor the instrument. The IRC framework allows the users to define a data analysis pipeline which converts data coming out of the instrument. The data can be used in visualizations in order for the user to assess the data in real-time, if necessary. The data analysis pipeline algorithms can be supplied by the user in a variety of forms or programming languages. Although the current integration effort is targeted for the High-resolution Airborne Wideband Camera (HAWC) and the Submillimeter and Far Infrared Experiment (SAFIRE), first-light instruments of the Stratospheric Observatory for Infrared Astronomy (SOFIA), the framework is designed to be generic and extensible so that it can be applied to any instrument. Plans are underway to test the framework

  18. Instrumentation and test gear circuits manual

    CERN Document Server

    Marston, R M

    2013-01-01

    Instrumentation and Test Gear Circuits Manual provides diagrams, graphs, tables, and discussions of several types of practical circuits. The practical circuits covered in this book include attenuators, bridges, scope trace doublers, timebases, and digital frequency meters. Chapter 1 discusses the basic instrumentation and test gear principles. Chapter 2 deals with the design of passive attenuators, and Chapter 3 with passive and active filter circuits. The subsequent chapters tackle 'bridge' circuits, analogue and digital metering techniques and circuitry, signal and waveform generation, and p

  19. Study of the trace element in organisms by neutron activation analysis, 1. Multielement instrumental neutron activation analysis of cannabis

    Energy Technology Data Exchange (ETDEWEB)

    Shinogi, M; Murai, Y; Mori, I [Kobe Women' s Coll. of Pharmacy (Japan); Takeuchi, T

    1974-12-01

    Examinations were made on optimal experimental conditions for instrumental determination of various elements in cannabis by neutron activation analysis, without any radiochemical separation, and the following conditions were found to be useful. Irradiation samples to be used are about 300 mg of the leaves or stem bark, and about 100 mg of the root. For soil sample, about 50 mg is used for the determination of short half-life nuclides and about 300 mg for long half-life nuclides. For short half-life nuclides, the samples are irradiated for 1 min, activity is measured for 200 sec after a decay of 3 min, and for 400 sec after a decay of 10 min. For long half-life nuclides, the samples are irradiated for 60 min and the activites are measured for 4 K sec after 1 week and for 10 K sec after 1 month. Use of supersonic waves is also convenient for cleansing of the samples. Thirty-five kinds of interesting elements were determined by this method from cannabis cultivated in Maizuru area.

  20. Engineering Analysis of the Recovered SAFOD Borehole Instrumentation

    International Nuclear Information System (INIS)

    Johnson, Wade

    2014-01-01

    The basic data set was acquired during 18 instrumentation setting tests conducted from 2004 through 2007 as part of SAFOD. Active hydrocarbon-rich water invaded the borehole because the borehole had not sealed at the bottom. For this reason, the water in the casing reached the cable head and caused a malfunction. Attempts were made to use better O rings, Krytox oil, and epoxy seal, but all failed. In most of these deployments, standard wire-line was used and the average failure time was two weeks. Based on design review, many improvements such as stainless tube encapsulate electric cables, all-metal seals, and Swageloks were applied. Setting of improved downhole instrument packages was carried out in the autumn of 2008. Still, these instruments could not endure the high temperature environment of 120 degrees Celsius for a long period of time, and all were offline in less than a month. A SAFOD engineering subcommittee was established in 2010 to investigate the problems caused through an examination of the removed instruments. It became clear that fluid including active hydrocarbons had invaded the stainless tubing from the seal part and caused all instruments to fail. Based on the above-mentioned experience, recommendations for the future are as follows. - Perform strict oversight of subcontractors. - Perform robust risk analysis and prepare a risk mitigation plan. - Multiple checks should be performed on points of failure by different people. - If possible, avoid the use of active electronics in environments like those in SAFOD. - Components must be rated for use in the temperature range of the environment in which they are to be used. - If a failure occurs, remove the instrumentation in a timely manner. - The SAFOD POD design was not inherently flawed but poorly implemented. (author)

  1. Taking spiritual history in clinical practice: a systematic review of instruments.

    Science.gov (United States)

    Lucchetti, Giancarlo; Bassi, Rodrigo M; Lucchetti, Alessandra L Granero

    2013-01-01

    To facilitate the addressing of spirituality in clinical practice, several authors have created instruments for obtaining a spiritual history. However, in only a few studies have authors compared these instruments. The aim of this study was to compare the most commonly used instruments for taking a spiritual history in a clinical setting. A systematic review of spiritual history assessment was conducted in five stages: identification of instruments used in the literature (databases searching); relevant articles from title and initial abstract review; exclusion and Inclusion criteria; full text retrieval and final analysis of each instrument. A total of 2,641 articles were retrieved and after the analysis, 25 instruments were included. The authors independently evaluated each instrument on 16 different aspects. The instruments with the greatest scores in the final analysis were FICA, SPIRITual History, FAITH, HOPE, and the Royal College of Psychiatrists. Concerning all 25 instruments, 20 of 25 inquire about the influence of spirituality on a person's life and 17 address religious coping. Nevertheless, only four inquire about medical practices not allowed, six deal with terminal events, nine have mnemonics to facilitate their use, and five were validated. FICA, SPIRITual History, FAITH, HOPE, and Royal College of Psychiatrists scored higher in our analysis. The use of each instrument must be individualized, according to the professional reality, time available, patient profile, and settings. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. The international surface temperature initiative

    Science.gov (United States)

    Thorne, P. W.; Lawrimore, J. H.; Willett, K. M.; Allan, R.; Chandler, R. E.; Mhanda, A.; de Podesta, M.; Possolo, A.; Revadekar, J.; Rusticucci, M.; Stott, P. A.; Strouse, G. F.; Trewin, B.; Wang, X. L.; Yatagai, A.; Merchant, C.; Merlone, A.; Peterson, T. C.; Scott, E. M.

    2013-09-01

    The aim of International Surface Temperature Initiative is to create an end-to-end process for analysis of air temperature data taken over the land surface of the Earth. The foundation of any analysis is the source data. Land surface air temperature records have traditionally been stored in local, organizational, national and international holdings, some of which have been available digitally but many of which are available solely on paper or as imaged files. Further, economic and geopolitical realities have often precluded open sharing of these data. The necessary first step therefore is to collate readily available holdings and augment these over time either through gaining access to previously unavailable digital data or through data rescue and digitization activities. Next, it must be recognized that these historical measurements were made primarily in support of real-time weather applications where timeliness and coverage are key. At almost every long-term station it is virtually certain that changes in instrumentation, siting or observing practices have occurred. Because none of the historical measures were made in a metrologically traceable manner there is no unambiguous way to retrieve the true climate evolution from the heterogeneous raw data holdings. Therefore it is desirable for multiple independent groups to produce adjusted data sets (so-called homogenized data) to adequately understand the data characteristics and estimate uncertainties. Then it is necessary to benchmark the performance of the contributed algorithms (equivalent to metrological software validation) through development of realistic benchmark datasets. In support of this, a series of successive benchmarking and assessment cycles are envisaged, allowing continual improvement while avoiding over-tuning of algorithms. Finally, a portal is proposed giving access to related data-products, utilizing the assessment results to provide guidance to end-users on which product is the most suited to

  3. Chemical characterization of gas- and oil-bearing shales by instrumental neutron activation analysis

    Science.gov (United States)

    Frost, J.K.; Koszykowski, R.F.; Klemm, R.C.

    1982-01-01

    The concentration of As, Ba, Ca, Co, Cr, Cs, Dy, Eu, Fe, Ga, Hf, K, La, Lu, Mn, Mo, Na, Ni, Rb, Sb, Sc, Se, Sm, Sr, Ta, Tb, Th, U, Yb, and Zn were determined by instrumental neutron activation analysis in block shale samples of the New Albany Group (Devonian-Mississippian) in the in the Illinois Basin. Uranium content of the samples was as high as 75 ppm and interfered in the determination of samarium, molybdenum, barium and cerium. In the determination of selenium a correction was made for interference from tantalum. U, As, Co, Mo, Ni and Sb as well as Cu, V and pyritic sulphur which were determined by other methods, were found to correlate positively with the organic carbon content of the samples. ?? 1982 Akade??miai Kiado??.

  4. Size spectra for trace elements in urban aerosol particles by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Ondov, J.M.; Divita, F. Jr.

    1993-01-01

    Size-fractionated aerosol samples collected with micro-orifice impactors at Camden, NJ, a heavily industrialized urban area, and at two sites near Washington, DC, were analyzed for elemental constituents determined instrumentally from short-lived neutron activation products. A least-squares peak-fitting method was used with impactor calibration data to determine log-normal distribution parameters, i.e., mass median aerodynamic diameter (MMAD) and geometric standard deviation (σ g ) for particles bearing S, V, Br, and I. For these elements, MMADs ranged from 0.24 to 0.65 μm; 0.23 to 0.53 μm; 0.22 to 0.61 μm, and 0.20 to 0.48 μm, respectively. (author) 15 refs.; 4 figs.; 2 tabs

  5. Use of microinterrupts to provide an instrument oriented input/output structure

    International Nuclear Information System (INIS)

    Zaky, S.G.

    1981-01-01

    This paper describes the design of a bit-slice based computer, which has been developed for use in data acquisition and control applications. The main design goals have been to provide fast response to external events, and sufficient processing capability to perform data reduction in real time. The initial application of this computer has been in airborne, geophysical surveying, where such instruments as Gamma-ray spectrometers, magnetometers and navigation equipment are involved. In order to meet the response requirement mentioned above, a microinterrupt facility has been incorporated. Microinterrupts are serviced in microcodes routines which can be initiated within a maximum of two microinstruction cycle times from an external event. This facility makes it possible to implement powerful input/output control functions without the need for complex and specialized hardware interfaces for each instrument. (orig.)

  6. ProRisk : risk analysis instrument : developed for William properties

    NARCIS (Netherlands)

    van Doorn, W.H.W.; Egeberg, Ingrid; Hendrickx, Kristoff; Kahramaner, Y.; Masseur, B.; Waijers, Koen; Weglicka, K.A.

    2005-01-01

    This report presents a Risk Analysis Instrument developed for William Properties. Based on the analysis, it appears that the practice of Risk Analysis exists within the organization, yet rather implicit. The Risk Analysis Instrument comes with a package of four components: an activity diagram, a

  7. Reactor instrumentation experience at IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Soares, A.J.

    1997-01-01

    The Instituto de Pesquisas Energeticas e Nucleares (IPEN) in Sao Paulo started in 1977 development of nuclear instrumentation. In 1982 two groups were established, one responsible for maintenance of electronic equipment and the other, the Nuclear Instrumentation Section (NIS), for new projects, such as a light water moderated critical facility (IPEN/MB-0). The NIS had the responsibility to execute all necessary activities to develop the ''nonconventional'' instrumentation systems: control, protection and radiation monitoring for the IPEN/MB-01 facility. After the commissioning of the critical facility the NIS group started the development of instrumentation systems for a power reactor. As a first step an overall review of the quality assurance programme was implemented. In parallel the development of self powered detectors was carried out. (author). 7 figs

  8. Optomechanical design of a hard x-ray nanoprobe instrument with active vibration control in nanometer scale

    International Nuclear Information System (INIS)

    Shu, D.; Maser, J.; Holt, M.; Winarski, R.; Preissner, C.; Smolyanitskiy, A.; Lai, B.; Vogt, S.; Stephenson, G.

    2007-01-01

    We are developing a new hard x-ray nanoprobe instrument that is one of the centerpieces of the characterization facilities of the Center for Nanoscale Materials being constructed at Argonne National Laboratory. This new probe will cover an energy range of 3-30 keV with 30-nm spatial resolution. The system is designed to accommodate x-ray optics with a resolution limit of 10 nm, therefore, it requires staging of x-ray optics and specimens with a mechanical repeatability of better than 5 nm. Fast feedback for differential vibration control between the zone-plate x-ray optics and the sample holder has been implemented in the design using a digital-signal-processor-based real-time closed-loop feedback technique. A specially designed, custom-built laser Doppler displacement meter system provides two-dimensional differential displacement measurements with subnanometer resolution between the zone-plate x-ray optics and the sample holder. The optomechanical design of the instrument positioning stage system with nanometer-scale active vibration control is presented in this paper.

  9. The Vector Electric Field Instrument on the C/NOFS Satellite

    Science.gov (United States)

    Pfaff, R.; Kujawski, J.; Uribe, P.; Bromund, K.; Fourre, R.; Acuna, M.; Le, G.; Farrell, W.; Holzworth, R.; McCarthy, M.; hide

    2008-01-01

    We provide an overview of the Vector Electric Field Instrument (VEFI) on the Air Force Communication/Navigation Outage Forecasting System (C/NOFS) satellite, a mission designed to understand, model, and forecast the presence of equatorial ionospheric irregularities. VEFI is a NASA GSFC instrument designed 1) to investigate the role of the ambient electric fields in initiating nighttime ionospheric density depletions and turbulence; 2) to determine the electric fields associated with abrupt, large amplitude, density depletions and 3) to quantify the spectrum of the wave electric fields and plasma densities (irregularities) associated with density depletions or Equatorial Spread-F. The VEFI instrument includes a vector electric field double probe detector, a Langmuir trigger probe, a flux gate magnetometer, a lightning detector and associated electronics. The heart of the instrument is the set of double probe detectors designed to measure DC and AC electric fields using 6 identical, mutually orthogonal, deployable 9.5 m booms tipped with 10 cm diameter spheres containing embedded preamplifiers. A description of the instrument and its sensors will be presented. If available, representative measurements will be provided.

  10. Development of multifunctional radiation monitoring instrument based on PLC technology

    International Nuclear Information System (INIS)

    Li Ziqiang; Zhu Yuye; Zhuang Min

    2007-01-01

    This eight-channel multifunctional Radiation Monitoring Instrument is developed by making use of the built-in high-speed counters and the powerful instruction system of the SIEMES SIMATICS S7 series Programmable Logic Controllers (PLC) to record and process the pulse signal output by the detectors. The instrument with functions, such as analog and digital display, digital storage of digital data, pulse signal generator, network communication, can connect various types of pulse detectors. The initial process can be translated between Graduation Apparatus method and Formula method. the logicality of the high-dosage warning system is processed itself. The signal output will drive the alarm lights and bell directly. This paper mainly describes the configuration, programming and feature of the instrument. (authors)

  11. 24 CFR 213.266 - Initial insurance endorsement.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Initial insurance endorsement. 213... insurance endorsement. The Commissioner shall indicate his insurance of the mortgage or supplementary loan by endorsing the original credit instrument and identifying the section of the Act and the...

  12. Direct payments as an instrument of the environmental policy

    Directory of Open Access Journals (Sweden)

    Adrian Sadłowski

    2011-01-01

    Full Text Available Agriculture is the area of human activity that is accompanied by the formation of positive and negative external environmental effects. In order to motivate farmers to conduct production activities in a way that reduces the negative impact of these activities on the environment, the so-called principle of cross compliance has been incorporated into the direct support system. This study characterises the area payments as an instrument of the environmental policy and is a review of the European Commission’s different proposals for the reform of direct payments through the prism of environmental functions of this instrument.

  13. Physical Activity Predicts Higher Physical Function in Older Adults: The Osteoarthritis Initiative.

    Science.gov (United States)

    Batsis, John A; Germain, Cassandra M; Vásquez, Elizabeth; Zbehlik, Alicia J; Bartels, Stephen J

    2016-01-01

    Physical activity reduces mobility impairments in elders. We examined the association of physical activity on risk of subjective and objective physical function in adults with and at risk for osteoarthritis (OA). Adults aged ≥ 60 years from the longitudinal Osteoarthritis Initiative, a prospective observational study of knee OA, were classified by sex-specific quartiles of Physical Activity Score for the Elderly scores. Using linear mixed models, we assessed 6-year data on self-reported health, gait speed, Late-Life Function and Disability Index (LLFDI) and chair stand. Of 2252 subjects, mean age ranged from 66 to 70 years. Within each quartile, physical component (PCS) of the Short Form-12 and gait speed decreased from baseline to follow-up in both sexes (all P physical activity is associated with maintained physical function and is mediated by muscle strength, highlighting the importance of encouraging physical activity in older adults with and at risk for OA.

  14. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  15. Determination of trace elements in bottled water in Greece by instrumental and radiochemical neutron activation analyses

    International Nuclear Information System (INIS)

    Soupioni, M.J.; Symeopoulos, B.D.; Papaefthymiou, H.V.

    2006-01-01

    Four different bottled water brands sold in Greece in the winter of 2001-2002 were analyzed for a wide range of chemical elements, using neutron activation analysis (NAA). The elements Na and Br were determined instrumentally (INAA), whereas the other metals and trace elements radiochemically (RNAA). The results indicated that the mean level of all the elements determined in the samples were well within the European Union (EU) directive on drinking water and accomplish the drinking water standards of the World Health Organisation (WHO) as well as of the Food and Drug Administration (FDA). (author)

  16. Oesophageal cancer in the Transkei. Determination of trace element concentrations in selected plant material by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Renan, M.J.; Drennan, B.D.; Keddy, R.J.; Sellschop, J.P.F.

    1979-01-01

    The results of the analysis by instrumental neutron activation for the concentration of trace elements in plant materials from certain areas in the Transkei region of southern Africa are presented. These areas are selected for their characteristic high or low incidence of carcinoma of the oesophagus. To broaden the suite of elements for which analysed and to overcome some of the limitations of neutron activation analysis, certain other nuclear analyses and methods are suggested which, if utilized, would increase the number of elements determined, and so improve the information available. (author)

  17. Instrumental neutron activation analysis of carbonatites from Homa Mountain, Kenya

    International Nuclear Information System (INIS)

    Ohde, S.

    2004-01-01

    Twenty eight (major and trace) elements including eight rare earth elements (REEs) in African carbonatite samples were determined by instrumental neutron activation analysis. The geochemical behavior of trace elements was studied in relation to the order of carbonatite intrusion from C1 to C4 through C2 and C3 at Homa Mountain, Kenya. The enrichment of Mn, Fe, Sr, Ba, Th, U and REE is found in the sixteen carbonatites examined in this study. The general increase in the concentrations of Na, Sc, Mn, Sb, Ba, Th, U and REE occurs from C1 to C4 through C2 and C2c, but C3 carbonatite shows a different pattern. The C3 carbonatite is extraordinarily enriched in Mn, Fe and Ba and is highly enriched in Cr, As, Sb and Th. The chondrite-normalized REE distribution pattern of the C3 carbonatite is not rich in the light REE. Strong fractionation between light and heavy REEs is found in the carbonatites, and moderate fractionation in the two alkalic igneous rock samples. In order to evaluate partitioning of REEs into carbonate, oxide and other mineral fractions, a selective chemical leaching technique on carbonatites was applied and is discussed. (author)

  18. Instrument Remote Control via the Astronomical Instrument Markup Language

    Science.gov (United States)

    Sall, Ken; Ames, Troy; Warsaw, Craig; Koons, Lisa; Shafer, Richard

    1998-01-01

    The Instrument Remote Control (IRC) project ongoing at NASA's Goddard Space Flight Center's (GSFC) Information Systems Center (ISC) supports NASA's mission by defining an adaptive intranet-based framework that provides robust interactive and distributed control and monitoring of remote instruments. An astronomical IRC architecture that combines the platform-independent processing capabilities of Java with the power of Extensible Markup Language (XML) to express hierarchical data in an equally platform-independent, as well as human readable manner, has been developed. This architecture is implemented using a variety of XML support tools and Application Programming Interfaces (API) written in Java. IRC will enable trusted astronomers from around the world to easily access infrared instruments (e.g., telescopes, cameras, and spectrometers) located in remote, inhospitable environments, such as the South Pole, a high Chilean mountaintop, or an airborne observatory aboard a Boeing 747. Using IRC's frameworks, an astronomer or other scientist can easily define the type of onboard instrument, control the instrument remotely, and return monitoring data all through the intranet. The Astronomical Instrument Markup Language (AIML) is the first implementation of the more general Instrument Markup Language (IML). The key aspects of our approach to instrument description and control applies to many domains, from medical instruments to machine assembly lines. The concepts behind AIML apply equally well to the description and control of instruments in general. IRC enables us to apply our techniques to several instruments, preferably from different observatories.

  19. Atmospheric-pressure electric discharge as an instrument of chemical activation of water solutions

    Science.gov (United States)

    Rybkin, V. V.; Shutov, D. A.

    2017-11-01

    Results of experimental studies and numerical simulations of physicochemical characteristics of plasmas generated in different types of atmospheric-pressure discharges (pulsed streamer corona, gliding electric arc, dielectric barrier discharge, glow-discharge electrolysis, diaphragmatic discharge, and dc glow discharge) used to initiate various chemical processes in water solutions are analyzed. Typical reactor designs are considered. Data on the power supply characteristics, plasma electron parameters, gas temperatures, and densities of active particles in different types of discharges excited in different gases and their dependences on the external parameters of discharges are presented. The chemical composition of active particles formed in water is described. Possible mechanisms of production and loss of plasma particles are discussed.

  20. Multielement analysis of rice flour-unpolished reference material by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Suzuki, Shogo; Hirai, Shoji

    1990-01-01

    Trace elements in NIES certified reference material No. 10-a∼10-c Rice Flour-Unpolished, prepared by the National Institute for Environmental Studies of Japan (NIES), were determined by instrumental neutron activation analysis (INAA). A set of three samples with different Cd concentration levels was subjected to analyses. Portions of each sample (ca. 200∼1000 mg) were irradiated, either with thermal neutrons without cadmium filter or with epithermal neutrons with cadmium filter, in the Musashi Institute of Technology Research Reactor (MITRR). The activated samples were analyzed by the three methods; conventional γ-ray spectrometry using a coaxial Ge detector, anticoincidence counting spectrometry, and coincidence counting spectrometry using a coaxial Ge detector and a well type NaI(Tl) detector. Concentrations of 26∼28 elements were determined by these methods. The values obtained for many elements, except for Mg and K, were in good agreement with those of the NIES certified and reference. Concentrations of 10 elements (S, Sc, V, Ag, Sb, Cs, Ba, La, Sm, Th), whose certified or reference values are not available from NIES, were also determined in this work. (author)

  1. Characteristic Elemental Composition of Oil Pigments using Instrumental Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Kim, Sun Ha; Sun, Gwang Min; Lim, Jong Myung; Moon, Jong Hwa; Kim, Young Jin; Lim, Sung Jin; Song, Yu Na; Kim, Ken

    2009-01-01

    The principal aim of this study is to identify the applicability of instrumental neutron activation analysis as a non-destructive examination tool for the quantitative composition analysis associated with authentication, restoration, and conservation of art objects in the field of cultural heritage. Generally, the chemical composition of pigments are associated with the colors such as white, yellow, orange, red, green, blue and black, and it varies with raw materials of pigments. According to the colors of a different pigments, chemical compositions are as follows; for example, white pigments were used for a mixture of Pb(CO 3 ) 2 , PbSO 4 , PbO, Pb(OH) 2 , ZnO, ZnS, TiO 2 , BaSO 4 , CaCO 3 , Al 2 O 3 , As 2 S 3 , etc.; black pigments were series of carbon black, borne ash, MnO+Mn 2 O 3 , etc.; red pigments were Fe 2 O 3 , Pb 3 O 4 , HgS, PbMo 4 , CdS+CdSe, etc.; brown and yellow pigments were PbCrO 4 , ZnCrO 4 , CdS-ZnS, K 3 [Co(NO 2 ) 6 ], Pb(SbO 3 ) 2 , C 19 H 16 O 11 Mg, SrCrO 4 , etc.; green pigments were Cr 2 O 3 , Cr 2 O(OH) 4 , Cu(C 2 H 3 O 2 )-2Cu(OH) 2 ), Cr 2 O 3 -Al 2 O 3 -CoO, etc.; blue pigments were Fe 4 [Fe(CN) 6 ] 3 , CoO-Al 2 O 3 , Na 8 - 10 Al 6 Si 6 O 24 S 2-4 , etc. This first step is to obtain quantitative data on the concentrations of major, minor and trace elements in oil pigments and to explain pigment sources by statistical treatment as reported in many literatures. The determination of major, minor and micro elements in the subject materials are essential in many fields of basic science and technology as well as commercial and industrial fields. In particular, direct analysis of a sample offers a more effective investigation method in these fields. Instrumental neutron activation analysis (INAA) has an inherent advantage of being a non-destructive, simultaneously multi-elemental analysis with high accuracy and sensitivity. In order to characterize the elemental contents of art objects, the quantitative analysis of oil pigment series was

  2. Synthetic multielement standards used for instrumental neutron activation analysis as rock imitations

    International Nuclear Information System (INIS)

    Leypunskaya, D.I.; Drynkin, V.I.; Belenky, B.V.; Kolomijtsev, M.A.; Dundera, V.Yu.; Pachulia, N.V.

    1975-01-01

    Complex (multielemental) standards representing microelement composition of standard rocks such as trap ST-1 (USSR), gabbrodiorite SGD-1 (USSR), albitized granite SG-1 (USSR), basalt BCR-1 (USA) and granodiorite GSP-1 (USA) have been synthesized. It has been shown that the concentration of each microelement in the synthetic standards can be given with a high precision. Comparative investigation has been carried out of the synthetic imitations and the above natural standard rocks. It has been found that the result of the instrumental neutron activation analysis using the synthetic standards is as good as in the case when natural standard rocks are used. The results obtained have been also used for substantiation of the versatility of the method used for standard preparation, i.e. a generalization has been made of a possibility of using this method for the preparation of synthetic standards representing the microelement composition of any natural rocks with various compositions and concentrations of microelements. (T.G.)

  3. Application of instrumental neutron activation analysis for the examination of oil pigments

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y.S.; Kim, S.H.; Sun, G.M.; Lim, J.M.; Moon, J.H.; Kim, Y.J. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lim, S.J.; Song, Y.N.; Kim, K. [National Museum of Contemporary Art, Gwacheon, Gyeonggi-do (Korea, Republic of)

    2011-07-01

    This study is to investigate the applicability of instrumental neutron activation analysis (INAA) as a non-destructive examination tool for the quantitative chemical composition analysis associated with authentication, restoration and conservation of art objects in the field of cultural heritage. The quantitative analysis of major, minor and trace elements in Rembrandt's {sup registered} oil pigments recently collected at the Korean market as one of the art objects was carried out using INAA facilities of the HANARO research reactor at the Korea Atomic Energy Research Institute in collaboration with the National Museum of Contemporary Art in Korea. Analytical quality control was implemented using NIST SRM 2709, certified reference materials and metal standards. The analytical results for seventeen characteristic elements of thirty-one measured elements were statistically treated to identify the characteristic correlations and patterns between color and source of oil pigment and similarity degree of constituents using a cluster and discriminate analysis. (orig.)

  4. Instrumental neutron activation analysis of dry atmospheric fall-out and rain-water

    International Nuclear Information System (INIS)

    Schutyser, P.; Maenhaut, W.; Dams, R.

    1978-01-01

    An automated precipitation sampler and an instrumental neutron activation analysis (i.n.a.a.) method for the determination of some major and trace elements in dry atmospheric fall-out and rain-water are presented. The sampler features a rain detector which makes separate collections of dry atmospheric fall-out and rain-water possible. The sampler is equipped with u.v. lamps in order to avoid algal growth during extended collection periods. After collection, the samples are separated into water-soluble and insoluble fractions. The soluble fraction is preconcentrated before analysis by freeze-drying. The i.n.a.a. method involves the measurement of both short- and long-lived radioactivities so that a total of 35 elements can be determined. The possibility of losses during freeze-drying and the accuracy of the i.n.a.a. method were investigated for 7 elements by analysis of a soluble fraction with an independent method, viz. inductively coupled plasma atomic emission spectrometry. (Auth.)

  5. An Optional Instrument for European Insurance Contract Law

    Directory of Open Access Journals (Sweden)

    Helmut Heiss

    2010-08-01

    Full Text Available The Principles of European Insurance Contract Law, also referred tousing the acronym PEICL, were published in September 2009. They are the result of ten years of academic work undertaken by the"Restatement of European Insurance Contract Law" Project Group. In the time since its establishment in 1999, the project has been transformed from being a stand-alone project to a part of the CoPECL (Common Principles of European Insurance Contract Law network, drafting a specific part of the Common Frame of Reference. Having continually worked under the guiding principle that "the law of insurance [in Europe] must be one," it now represents a serious option for providing Europe with a single legal framework for insurance contracts.Despite the European Council's proclamations that the Common Frame of Reference will remain a non-binding instrument, the implementation of one or more optional instruments in the future does not appear to beimprobable considering recent developments. The possibility of anoptional instrument has been expressed more than once by the European Commission in its Action Plan and Communication on European Contract Law. Other indications in favour of an optional instrument include the European Parliament's repeated references to the Common Frame of Reference as providing, at the very least, a model for a futureoptional instrument, as well as the EESC's earlier proposal of anoptional instrument as an alternative to standardising insurancecontract law. The preparation by the EESC of another (own-initiative opinion on European contract law is underway, and its presentation is anticipated in 2010. Hence, the optional instrument is evidently the subject of serious political deliberation. Using Article 1:102, the Principles of European Insurance Contract Law represent a prototype for such an instrument.

  6. An Optional Instrument for European Insurance Contract Law

    Directory of Open Access Journals (Sweden)

    Mandeep Lakhan

    2010-08-01

    Full Text Available The Principles of European Insurance Contract Law, also referred tousing the acronym PEICL, were published in September 2009. They are the result of ten years of academic work undertaken by the"Restatement of European Insurance Contract Law" Project Group. In the time since its establishment in 1999, the project has been transformed from being a stand-alone project to a part of the CoPECL (Common Principles of European Insurance Contract Law network, drafting a specific part of the Common Frame of Reference. Having continually worked under the guiding principle that "the law of insurance [in Europe] must be one," it now represents a serious option for providing Europe with a single legal framework for insurance contracts. Despite the European Council's proclamations that the Common Frame of Reference will remain a non-binding instrument, the implementation of one or more optional instruments in the future does not appear to beimprobable considering recent developments. The possibility of anoptional instrument has been expressed more than once by the European Commission in its Action Plan and Communication on European Contract Law. Other indications in favour of an optional instrument include the European Parliament's repeated references to the Common Frame of Reference as providing, at the very least, a model for a futureoptional instrument, as well as the EESC's earlier proposal of anoptional instrument as an alternative to standardising insurancecontract law. The preparation by the EESC of another (own-initiative opinion on European contract law is underway, and its presentation is anticipated in 2010. Hence, the optional instrument is evidently the subject of serious political deliberation. Using Article 1:102, the Principles of European Insurance Contract Law represent a prototype for such an instrument.

  7. Shortening of an existing generic online health-related quality of life instrument for dogs.

    Science.gov (United States)

    Reid, J; Wiseman-Orr, L; Scott, M

    2017-10-11

    Development, initial validation and reliability testing of a shortened version of a web-based questionnaire instrument to measure generic health-related quality of life in companion dogs, to facilitate smartphone and online use. The original 46 items were reduced using expert judgment and factor analysis. Items were removed on the basis of item loadings and communalities on factors identified through factor analysis of responses from owners of healthy and unwell dogs, intrafactor item correlations, readability of items in the UK, USA and Australia and ability of individual items to discriminate between healthy and unwell dogs. Validity was assessed through factor analysis and a field trial using a "known groups" approach. Test-retest reliability was assessed using intraclass correlation coefficients. The new instrument comprises 22 items, each of which was rated by dog owners using a 7-point Likert scale. Factor analysis revealed a structure with four health-related quality of life domains (energetic/enthusiastic, happy/content, active/comfortable, and calm/relaxed) accounting for 72% of the variability in the data compared with 64% for the original instrument. The field test involving 153 healthy and unwell dogs demonstrated good discriminative properties and high intraclass correlation coefficients. The 22-item shortened form is superior to the original instrument and can be accessed via a mobile phone app. This is likely to increase the acceptability to dog owners as a routine wellness measure in health care packages and as a therapeutic monitoring tool. © 2017 British Small Animal Veterinary Association.

  8. Iron Quadrangle, Brazil. Elemental concentration determined by k0-instrumental neutron activation analysis. Part 1. Soil samples

    International Nuclear Information System (INIS)

    Menezes, M.A.B.C.; Palmieri, H.E.L.; Leonel, L.V.; Nalini, H.A.Jr.; Jacimovic, R.

    2006-01-01

    The Iron Quadrangle, Minas Gerais, Brazil, is rich in mineral occurrences and is considered one of the richest mineral-bearing regions in the world. Most investigations in this region have dealt with the determination of arsenic and mercury but so far few studies have been carried out aiming at determining other important elements. Having in mind the potential risk caused by mineral activities, this study was developed in order to assess the potential influence of the soil on foodstuffs. The soil samples were collected from three sites inside and outside the Iron Quadrangle. The samples were analyzed at the Laboratory for Neutron Activation Analysis, CDTN/CNEN by the k 0 -instrumental neutron activation analysis. This paper reports the elemental concentration determined in soil and emphasises the elements cited in the Brazilian environmental legislation for soil. This work also confirms the high elemental concentration of several minerals, however, it is difficult to distinguish the contamination from anthropogenic activities from the natural occurrence. (author)

  9. Evaluating performance characteristics of x-ray equipment and film systems without the use of electronic measurement and/or special instruments

    International Nuclear Information System (INIS)

    Bianchi, M.F.; DeNitto, C.; Liscio, A.; Scala, N.

    2004-01-01

    Measurement and control of characteristics of NDT equipment and system that produce output to be interpreted by inspector is one of the most important tools for NDT reliability. Control activity should be based on: initial accurate measurement and calibration; periodical check to assure maintenance of calibration status; and, immediate verification and corrective action when any malfunctioning is suspected. 'Self-calibration' intended as capability of NDT facility to calibrate and control its own equipment and systems is very important for continuous and reliable activity. Typical approach based on this philosophy is ASTM E317 'Standard Practice for Evaluating Performance Characteristics of Ultrasonic Pulse-Echo Examination Instruments and Systems Without the Use of Electronic Measurement Instruments' that is applicable to shop or field conditions. Is 'Self-calibration' applicable to radiographic system too? Many characteristics can be self-determined according to existing practices and methods, but other ones require assistance and cooperation of supplier both for film system and x-ray equipment. A certified film system being controlled by pre-exposed filmstrips can be adopted as 'measurement device' for X-ray output concerning both intensity and contrast. Basically x-ray equipment manufacturer performs initial accurate measurement and calibration using electronic measurement and/or special instrumentation as necessary. Then specific film set on 'low-price' blocks and specimens is produced according to standard practice whose guidelines are supplied by this paper. Film set, blocks, specimens and results referred to specific film system will be the reference kit for periodical check in NDT facility. This paper supplies some guidelines for standard practice based on testing using mainly GE Inspection Technologies radiographic system being available in Avio facilities. (author)

  10. International Working Group on Nuclear Power Plant Control and Instrumentation: Recent activities and future prospects

    International Nuclear Information System (INIS)

    Kossilov, A.

    1992-01-01

    The IWG-NPPCI working group exists to consider developments, disseminate and exchange experience in all aspects of instrumentation, control and information technology relevant to the safety and economics of NPP design and operation. The main topics dealt with are: nuclear instrumentation, control systems, protection systems, early failure detection and diagnosis, use of computer technology in NPP operation, instrumentation for accidental situation, operator support systems, man-machine interface. The main objectives of the IWG-NPPCI are: to assist the IAEA to provide the Member States with information and recommendations on technical aspects of the NPP control and instrumentation with the aim to assure reliable functions; to promote and exchange of information on national programs, new developments and experience from operating NPPs, and to stimulate the coordination of research on NPP control and instrumentation

  11. International Working Group on Nuclear Power Plant Control and Instrumentation: Recent activities and future prospects

    Energy Technology Data Exchange (ETDEWEB)

    Kossilov, A [International Atomic Energy Agency, Vienna (Austria)

    1992-07-01

    The IWG-NPPCI working group exists to consider developments, disseminate and exchange experience in all aspects of instrumentation, control and information technology relevant to the safety and economics of NPP design and operation. The main topics dealt with are: nuclear instrumentation, control systems, protection systems, early failure detection and diagnosis, use of computer technology in NPP operation, instrumentation for accidental situation, operator support systems, man-machine interface. The main objectives of the IWG-NPPCI are: to assist the IAEA to provide the Member States with information and recommendations on technical aspects of the NPP control and instrumentation with the aim to assure reliable functions; to promote and exchange of information on national programs, new developments and experience from operating NPPs, and to stimulate the coordination of research on NPP control and instrumentation.

  12. "helix Nebula - the Science Cloud", a European Science Driven Cross-Domain Initiative Implemented in via AN Active Ppp Set-Up

    Science.gov (United States)

    Lengert, W.; Mondon, E.; Bégin, M. E.; Ferrer, M.; Vallois, F.; DelaMar, J.

    2015-12-01

    Helix Nebula, a European science cross-domain initiative building on an active PPP, is aiming to implement the concept of an open science commons[1] while using a cloud hybrid model[2] as the proposed implementation solution. This approach allows leveraging and merging of complementary data intensive Earth Science disciplines (e.g. instrumentation[3] and modeling), without introducing significant changes in the contributors' operational set-up. Considering the seamless integration with life-science (e.g. EMBL), scientific exploitation of meteorological, climate, and Earth Observation data and models open an enormous potential for new big data science. The work of Helix Nebula has shown that is it feasible to interoperate publicly funded infrastructures, such as EGI [5] and GEANT [6], with commercial cloud services. Such hybrid systems are in the interest of the existing users of publicly funded infrastructures and funding agencies because they will provide "freedom and choice" over the type of computing resources to be consumed and the manner in which they can be obtained. But to offer such freedom and choice across a spectrum of suppliers, various issues such as intellectual property, legal responsibility, service quality agreements and related issues need to be addressed. Finding solutions to these issues is one of the goals of the Helix Nebula initiative. [1] http://www.egi.eu/news-and-media/publications/OpenScienceCommons_v3.pdf [2] http://www.helix-nebula.eu/events/towards-the-european-open-science-cloud [3] e.g. https://sentinel.esa.int/web/sentinel/sentinel-data-access [5] http://www.egi.eu/ [6] http://www.geant.net/

  13. MIT Participation in the Data Analysis of the XRS and XIS Instruments on the Astro-E2 Mission

    Science.gov (United States)

    Bautz, Mark

    2005-01-01

    Since the inception of this grant six weeks ago, we have completed the initial activation of the Suzaku X-ray Imaging Spectrometer (XIS) (on 13 August) and we have supported initial calibration observations. The instrument is performing very well in all respects. We have characterized the spectral resolution and effective area of each XIS sensor. We are especially excited about the scientific opportunities provided by the XIS'S back- illuminated sensor, which exhibits spectral resolution in the sub-keV band unmatched by any X-ray CCD currently in orbit. As specified in our proposal, we have established a web site (http://space.mit.edu/XIS) on which we maintain an up-to-date summary of instrument performance characteristics. Gain, spectral resolution and system noise, as well as residual background rates, are currently available on this site. Although the particle background level is low compared with Chandra and XMM, we are currently evaluating methods to reduce it still further. Techniques under study include use of 5x5 mode information and alternative grade selection methods. Although the primary responsibility for development of instrument response functions rests with our Japanese colleagues, we are incorporating our latest measurements of spectral resolution into some temporary response functions which we hope to make available to the Suzaku General Observer Facility and the Science Working Group(SWG). We are also preparing proposals for use of SWG observing time.

  14. An overview of therapeutic initiatives when working with persons suffering from dementia

    DEFF Research Database (Denmark)

    Ridder, Hanne Mette Ochsner

    2005-01-01

    In this chapter I will describe how music is used in a wide range of initiatives with persons suffering from dementia. There are various ways of implementing music: in groups or individually, by singing songs, listening to music, dancing, or improvising on instruments. I hope to give an introduct......In this chapter I will describe how music is used in a wide range of initiatives with persons suffering from dementia. There are various ways of implementing music: in groups or individually, by singing songs, listening to music, dancing, or improvising on instruments. I hope to give...

  15. Radiation-initiated free-radical fragmentation of biologically active glycerides

    International Nuclear Information System (INIS)

    Akhrem, A.A.; Kisel', M.A.; Shadyro, O.I.; Yurkova, I.L.

    1993-01-01

    Oxidation reactions of the free-radical type play a decisive role in the initial processes of radiation damage. The most suitable substrates for such reactions are lipids. Lipids are a basic structural element of biomembranes and are involved in the barrier function and biocatalytic activity of such membranes. Free-radical degradation of membrane lipids can lead to serious damage and ultimately to destruction of the living cell. A well-studied type of free-radical conversion of lipids is oxidation of polyunsaturated fatty acid residues, so-called peroxide oxidation of lipids. In this paper, using as examples dimyristoylphosphatidyl glycerol (DMPG), monoglycerides, and glycerophosphate, the authors investigated the possibility of free-radical degradation in compounds of a lipid nature containing the α,β-bifunctional group

  16. Application of instrumental neutron activation analysis to study ceramic fragments from Damascus Castle site, Syria

    International Nuclear Information System (INIS)

    Bakraji, E.H.

    2005-01-01

    Thirty-three archaeological ceramic fragment samples from Damascus Castle archaeological site, Damascus city, Syria, were analyzed using instrumental neutron activation analysis (INAA). 36 elements were determined. These elemental concentrations have been processed using two multivariate statistical methods, cluster and factor analysis in order to determine similarities and correlation between the various samples. Factor analysis confirms that 84.8% of the ceramics samples classified by cluster analysis are correctly classified by cluster analysis. The results provided persuasive evidence that Castle pottery used at least four different clay sources. Moreover, by means of systematic local analysis it will be clear whether these sources are local or not. (author)

  17. Initial Development Work for the Cloud-Aerosol Multi-Angle Lidar

    Data.gov (United States)

    National Aeronautics and Space Administration — Initiate development of a cost-effective off-nadir cloud-aerosol lidar instrument to enable data synergy with passive sensors (imagers, polarimeters) and models...

  18. Activities in the Dynamic Occupational Therapy Method

    Directory of Open Access Journals (Sweden)

    Jô Benetton

    2013-12-01

    Full Text Available This paper addresses the concept and use of the instrument named ‘activities’ in occupational therapy, sustained by the propositions of the Dynamic Occupational Therapy Method (DOTM. Initially, we present general aspects related to the activities in the DOTM such as the option for the name ‘activities’, its conceptual definition, use as a tool, and active participation in the dynamic of triadic relationship. Further, it approaches the character of activities: therapeutic, educational and social qualities, which distinguish this peculiar occupational therapy. Moreover, the paper highlights the use of activities as a tool, both as a central element of the processes that should underpin clinical reasoning (observation, information, association, setting up space of historicity, and construction of narrative, and as an element belonging to diagnostic procedures, to the course of clinical process, and to evaluation. Finally, we present our understanding of what we call resources in DOTM, and its intrinsic connection with the possibility of performing ‘activities’. For the creation of DOTM, occupational therapy, as a practice focused on the uniqueness of the case, was made the object of study in order to promote knowledge construction. The conceptual and instrumental framework presented in this work held this effort. We hope that this study could be useful for initial and continuing training in Occupational Therapy as well as for enriching the debate on the use of ‘activities’ in our profession.

  19. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  20. Nuclear data and the effects of its inconsistency on instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Ahmed, Y.A.; Ewa, I.O.B.; Umar, I.M.

    2006-04-01

    In this study, we examine the role of nuclear data in Instrumental Neutron Activation Analysis (INAA) particularly as it affects determination of reactor flux parameters and application of comparator methods. The work reviewed the available sources of nuclear data, the variations that exist from one source to the other and the effects of such variations on INAA. Measurement of Neutron flux parameters in inner and outer irradiation channel of a miniature neutron source reactor was carried out using two independent nuclear data sources to investigate the effects of inconsistency of nuclear data on the precision of analytical result. The result obtained shows a slight variation of flux parameters with nuclear data source. It was also observed that modification of the earlier compiled basic nuclear data lead to inconsistencies in the secondary data that applies it. (author)

  1. Instrumentness for Creativity - Mediation, Materiality & Metonymy

    DEFF Research Database (Denmark)

    Bertelsen, Olav Wedege; Breinbjerg, Morten; Pold, Søren

    2007-01-01

    in use beyond what is initially designed for. The paper performs a conceptual investigation into qualities in software interfaces that support creativity, supported by analysis of, and interviews with, musical composers. Instrumentness is explained through discussions of materiality and metonymy...... as central strategies for computer mediated creativity. The paper is contributing to an investigation of the aesthetics of use in relation to software, pointing to alternative values, differing from traditional usability, which are also relevant in creative work outside art and music composition....

  2. Activation of inactivation process initiates rapid eye movement sleep.

    Science.gov (United States)

    Mallick, Birendra Nath; Singh, Abhishek; Khanday, Mudasir Ahmad

    2012-06-01

    Interactions among REM-ON and REM-OFF neurons form the basic scaffold for rapid eye movement sleep (REMS) regulation; however, precise mechanism of their activation and cessation, respectively, was unclear. Locus coeruleus (LC) noradrenalin (NA)-ergic neurons are REM-OFF type and receive GABA-ergic inputs among others. GABA acts postsynaptically on the NA-ergic REM-OFF neurons in the LC and presynaptically on the latter's projection terminals and modulates NA-release on the REM-ON neurons. Normally during wakefulness and non-REMS continuous release of NA from the REM-OFF neurons, which however, is reduced during the latter phase, inhibits the REM-ON neurons and prevents REMS. At this stage GABA from substantia nigra pars reticulate acting presynaptically on NA-ergic terminals on REM-ON neurons withdraws NA-release causing the REM-ON neurons to escape inhibition and being active, may be even momentarily. A working-model showing neurochemical-map explaining activation of inactivation process, showing contribution of GABA-ergic presynaptic inhibition in withdrawing NA-release and dis-inhibition induced activation of REM-ON neurons, which in turn activates other GABA-ergic neurons and shutting-off REM-OFF neurons for the initiation of REMS-generation has been explained. Our model satisfactorily explains yet unexplained puzzles (i) why normally REMS does not appear during waking, rather, appears following non-REMS; (ii) why cessation of LC-NA-ergic-REM-OFF neurons is essential for REMS-generation; (iii) factor(s) which does not allow cessation of REM-OFF neurons causes REMS-loss; (iv) the association of changes in levels of GABA and NA in the brain during REMS and its deprivation and associated symptoms; v) why often dreams are associated with REMS. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. 77 FR 60124 - Draft Guidance for Industry on Initial Completeness Assessments for Type II Active Pharmaceutical...

    Science.gov (United States)

    2012-10-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-D-1010] Draft Guidance for Industry on Initial Completeness Assessments for Type II Active Pharmaceutical... certain drug master files, namely, Type II active pharmaceutical ingredient (API) drug master files (DMFs...

  4. Characterization of HPGe gamma spectrometric detectors systems for Instrumental Neutron Activation Analysis (INAA) at the Colombian Geological Survey

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, O., E-mail: osierra@sgc.gov.co; Parrado, G., E-mail: gparrado@sgc.gov.co; Cañón, Y.; Porras, A.; Alonso, D.; Herrera, D. C.; Peña, M., E-mail: mlpena@sgc.gov.co; Orozco, J. [Colombian Geological Survey, Nuclear Affairs Technical Division, Neutron Activation Analysis Laboratory, Bogota D. C. (Colombia)

    2016-07-07

    This paper presents the progress made by the Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey (SGC in its Spanish acronym), towards the characterization of its gamma spectrometric systems for Instrumental Neutron Activation Analysis (INAA), with the aim of introducing corrections to the measurements by variations in sample geometry. Characterization includes the empirical determination of the interaction point of gamma radiation inside the Germanium crystal, through the application of a linear model and the use of a fast Monte Carlo N-Particle (MCNP) software to estimate correction factors for differences in counting efficiency that arise from variations in sample density between samples and standards.

  5. Moving the Barricades to Physical Activity: A Qualitative Analysis of Open Streets Initiatives Across the United States.

    Science.gov (United States)

    Eyler, Amy A; Hipp, J Aaron; Lokuta, Julie

    2015-01-01

    Ciclovía, or Open Streets initiatives, are events where streets are opened for physical activity and closed to motorized traffic. Although the initiatives are gaining popularity in the United States, little is known about planning and implementing them. The goals of this paper are to explore the development and implementation of Open Streets initiatives and make recommendations for increasing the capacity of organizers to enhance initiative success. Phenomenology with qualitative analysis of structured interviews was used. Study setting was urban and suburban communities in the United States. Study participants were organizers of Open Streets initiatives in U.S. cities. Using a list of 47 events held in 2011, 27 lead organizers were interviewed by telephone about planning, implementation, and lessons learned. The interviews were digitally recorded and transcribed. A phenomenologic approach was used, an initial coding tool was developed after reviewing a sample of transcripts, and constant comparative coding methodology was applied. Themes and subthemes were generated from codes. The most common reasons for initiation were to highlight or improve health and transportation. Most initiatives aimed to reach the general population, but some targeted families, children, or specific neighborhoods. Getting people to understand the concept of Open Streets was an important challenge. Other challenges included lack of funding and personnel, and complex logistics. These initiatives democratize public space for citizens while promoting physical activity, social connectedness, and other broad agendas. There are opportunities for the research community to contribute to the expanse and sustainability of Open Streets, particularly in evaluation and dissemination.

  6. 26 CFR 1.1275-5 - Variable rate debt instruments.

    Science.gov (United States)

    2010-04-01

    ... nonpublicly traded property. A debt instrument (other than a tax-exempt obligation) that would otherwise... variations in the cost of newly borrowed funds in the currency in which the debt instrument is denominated... on the yield of actively traded personal property (within the meaning of section 1092(d)(1)). (ii...

  7. Non-destructive determination of nitrogen in malting barleys by instrumental photon activation analysis and its comparison with the Dumas method

    Czech Academy of Sciences Publication Activity Database

    Krausová, Ivana; Mizera, Jiří; Dostálek, P.; Řanda, Zdeněk

    2018-01-01

    Roč. 124, č. 1 (2018), s. 4-8 ISSN 0046-9750 R&D Projects: GA ČR(CZ) GBP108/12/G108 Institutional support: RVO:61389005 Keywords : nitrogen * instrumental photon activation analysis * Dumas method * malting barley Subject RIV: GM - Food Processing OBOR OECD: Food and beverages Impact factor: 0.859, year: 2016

  8. Study of the long-range transport of atmospheric pollutants by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Jin Yangshao

    1994-01-01

    Aerosol samples were collected to study the characteristics of marine aerosols in the different western Pacific ocean areas. During the first cruise from 15 October to 25 November 1989, aerosol samples were collected with a kA-200 Andersen cascade impactor and a kB-120 sampler. Instrumental neutron activation analysis was used to determine the elemental composition of the aerosols. The concentrations of crustal and pollution elements in aerosols were higher over the ocean area close to the China coast and decreased very rapidly with increasing distance from land. The morphology and elemental composition of aerosol particles showed that the seasalt particles may conglomerate with small crustal and pollution particles from land to form large particles. (author). 4 refs, 1 fig., 1 tab

  9. Achieving a predictable 24-hour return to normal activities after breast augmentation: part II. Patient preparation, refined surgical techniques, and instrumentation.

    Science.gov (United States)

    Tebbetts, John B

    2006-12-01

    The goal of this study was to develop practices that would allow patients undergoing subpectoral augmentation to predictably return to full normal activities within 24 hours after the operation, free of postoperative adjuncts. Part I of this study used motion and time study principles to reduce operative times, medication dosages, perioperative morbidity, and recovery times in augmentation mammaplasty. Part II of the study focuses on details of patient education, preoperative planning, instrumentation, and surgical technique modifications that were identified, modified, and implemented to achieve the results reported in part I. Two groups of 16 patients each (groups 1 and 2) were studied retrospectively for comparison to a third group of 627 patients (group 3) studied prospectively. Patients in group 1 had axillary partial retropectoral breast augmentations in 1982-1983, using dissociative anesthesia, blunt instrument implant pocket dissection, and Dow Corning, double-lumen implants containing 20 mg of methylprednisolone and 20 cc of saline in the outer lumen of the implants. Patients in group 2 (1990) had inframammary, retromammary augmentations by using a combination of blunt and electrocautery dissection, Surgitek Replicon polyurethane-covered, silicone gel-filled implants, and general endotracheal anesthesia. Patients in group 3 (1998 to 2001, n = 627) had inframammary partial retropectoral, inframammary retromammary, and axillary partial retropectoral augmentations under general endotracheal anesthesia. Refined practices and surgical techniques from studies of groups 1 and 2 were applied in group 3. Videotapes from operative procedures of groups 1 and 2 were analyzed with macromotion and micromotion study principles, and tables of events were formulated for each move during the operation for all personnel in the operating room. Extensive details of surgical technique were examined and reexamined in 13 different stages by using principles of motion and time

  10. Regulatory requirements and quality assurance of radiation monitoring instruments

    International Nuclear Information System (INIS)

    Narasimharao, K.L.; Sharma, Ranjit

    2005-01-01

    The successful utilisation of radiation sources in the fields of medicine and industry requires the accurate measurement of activity, exposure rate and dose. Many varieties of instruments are in use for measurement of these parameters and new ones are being developed. The criteria for the design of the radiation monitoring instrument include the type and intensity of the radiation, purpose of measurement and ruggedness of the instrument. Quality and reliability of radiation monitoring instruments ensure that individuals are adequately protected. Accuracy, response time and ruggedness are required to be as per the approved/ prescribed guidelines. Regulatory authorities outline the design and performance criteria for radiation monitoring instruments and prescribe the recommendations of international agencies such as IAEA, ICRU and ISO for radiological measurement assurance programme. National Standards Laboratories all over the world prescribe procedures for calibration of various radiation monitoring instruments. The instruments should be calibrated as per these guidelines and should be traceable to national standards. The calibration traceable to national/ international standards and documentation as well as limits stipulated by the competent authority ensures the expected performance of the instrument. (author)

  11. Systems biology of coagulation initiation: kinetics of thrombin generation in resting and activated human blood.

    Directory of Open Access Journals (Sweden)

    Manash S Chatterjee

    2010-09-01

    Full Text Available Blood function defines bleeding and clotting risks and dictates approaches for clinical intervention. Independent of adding exogenous tissue factor (TF, human blood treated in vitro with corn trypsin inhibitor (CTI, to block Factor XIIa will generate thrombin after an initiation time (T(i of 1 to 2 hours (depending on donor, while activation of platelets with the GPVI-activator convulxin reduces T(i to ∼20 minutes. Since current kinetic models fail to generate thrombin in the absence of added TF, we implemented a Platelet-Plasma ODE model accounting for: the Hockin-Mann protease reaction network, thrombin-dependent display of platelet phosphatidylserine, VIIa function on activated platelets, XIIa and XIa generation and function, competitive thrombin substrates (fluorogenic detector and fibrinogen, and thrombin consumption during fibrin polymerization. The kinetic model consisting of 76 ordinary differential equations (76 species, 57 reactions, 105 kinetic parameters predicted the clotting of resting and convulxin-activated human blood as well as predicted T(i of human blood under 50 different initial conditions that titrated increasing levels of TF, Xa, Va, XIa, IXa, and VIIa. Experiments with combined anti-XI and anti-XII antibodies prevented thrombin production, demonstrating that a leak of XIIa past saturating amounts of CTI (and not "blood-borne TF" alone was responsible for in vitro initiation without added TF. Clotting was not blocked by antibodies used individually against TF, VII/VIIa, P-selectin, GPIb, protein disulfide isomerase, cathepsin G, nor blocked by the ribosome inhibitor puromycin, the Clk1 kinase inhibitor Tg003, or inhibited VIIa (VIIai. This is the first model to predict the observed behavior of CTI-treated human blood, either resting or stimulated with platelet activators. CTI-treated human blood will clot in vitro due to the combined activity of XIIa and XIa, a process enhanced by platelet activators and which proceeds

  12. Instrumental interaction

    OpenAIRE

    Luciani , Annie

    2007-01-01

    International audience; The expression instrumental interaction as been introduced by Claude Cadoz to identify a human-object interaction during which a human manipulates a physical object - an instrument - in order to perform a manual task. Classical examples of instrumental interaction are all the professional manual tasks: playing violin, cutting fabrics by hand, moulding a paste, etc.... Instrumental interaction differs from other types of interaction (called symbolic or iconic interactio...

  13. A Mixed Methods Portrait of Urban Instrumental Music Teaching

    Science.gov (United States)

    Fitzpatrick, Kate R.

    2011-01-01

    The purpose of this mixed methods study was to learn about the ways that instrumental music teachers in Chicago navigated the urban landscape. The design of the study most closely resembles Creswell and Plano Clark's (2007) two-part Triangulation Convergence Mixed Methods Design, with the addition of an initial exploratory focus group component.…

  14. The knowledge, efficacy, and practices instrument for oral health providers: a validity study with dental students.

    Science.gov (United States)

    Behar-Horenstein, Linda S; Garvan, Cyndi W; Moore, Thomas E; Catalanotto, Frank A

    2013-08-01

    Valid and reliable instruments to measure and assess cultural competence for oral health care providers are scarce in the literature, and most published scales have been contested due to a lack of item analysis and internal estimates of reliability. The purposes of this study were, first, to develop a standardized instrument to measure dental students' knowledge of diversity, skills in culturally competent patient-centered communication, and use of culture-centered practices in patient care and, second, to provide preliminary validity support for this instrument. The initial instrument used in this study was a thirty-six-item Likert-scale survey entitled the Knowledge, Efficacy, and Practices Instrument for Oral Health Providers (KEPI-OHP). This instrument is an adaption of an initially thirty-three-item version of the Multicultural Awareness, Knowledge, and Skills Scale-Counselor Edition (MAKSS-CE), a scale that assesses factors related to social justice, cultural differences among clients, and cross-cultural client management. After the authors conducted cognitive and expert interviews, focus groups, pilot testing, and item analysis, their initial instrument was reduced to twenty-eight items. The KEPI-OHP was then distributed to 916 dental students (response rate=48.6 percent) across the United States to measure its reliability and assess its validity. Both exploratory and confirmatory factor analyses were conducted to test the scale's validity. The modification of the survey into a sensible instrument with a relatively clear factor structure using factor analysis resulted in twenty items. A scree test suggested three expressive factors, which were retained for rotation. Bentler's comparative fit and Bentler and Bonnett's non-normed indices were 0.95 and 0.92, respectively. A three-factor solution, including efficacy of assessment, knowledge of diversity, and culture-centered practice subscales, comprised of twenty-items was identified. The KEPI-OHP was found to

  15. Multielement characterization of atmospheric pollutants by x-ray fluorescence analysis and instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Rancitelli, L.A.; Tanner, T.M.

    1976-01-01

    The simultaneous measurement of a wide spectrum of elements in aerosols collected on air filters and in rainwater can yield information on the origin, transport, and removal of atmospheric pollutants. In order to determine the elemental content of these aerosols, a pair of highly sensitive, precise and complementing instrumental techniques, x-ray fluorescence and neutron activation analysis, have been developed and employed. Data are presented on the results of combined x-ray fluorescence and activation analysis of aerosols collected in a number of urban areas of the USA and from the 80th median sampling network in March 1972. From a comparison of these ratios in granite and diabase with those of filters placed in urban areas, it is evident that Zn, Se, Sb, Hg, and Pb levels have been increased by as much as several orders of magnitude. Al, Co, La, Fe, Eu, Sm, Tb, Ta, Hf, and Th appear to exist at levels compatible with an earth's crust origin

  16. Geochemistry of single diamond crystals by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Damarupurshad, A.

    1995-02-01

    Neutron activation analysis is probably the most powerful technique, available to date, for the analysis of the trace elements in diamond. In this study the technique of neutron activation analysis has been modified and optimized for the analysis of single, small (0.01-0.5 carat), inclusion-bearing and inclusion-free diamonds. Instrumental neutron activation analysis was used to analyze for up to 40 different elements at the ppb and ppt levels in diamonds from Brazil, South Africa, Colorado and China. The data obtained was used to detect and understand the differences between diamonds from the eclogitic and peridotitic para geneses and between diamonds from the different localities. In this regard, two inter element ratios, i.e. Cr/Sc and Au/Ir ratios were found to be useful. It seems that diamonds from a particular locality or mine have a unique range of Cr/Sc ratios. Furthermore, the identity of the dominant silicate inclusion(s) can be deduced from the Cr/Sc ratio of the diamond, since each type of silicate inclusion has a different range of Cr/Sc ratios. Not only is the Cr/Sc ratio distinctive for silicate inclusions in diamonds, it is also distinctive for minerals co genetic with diamond, such as orange garnet, red garnet, chrome diopside and ortho pyroxene (macrocrysts) which were separated from kimberlites. Sulphide inclusions may also contain detectable quantities of Au and Ir and the ratios of these two elements can also be used to differentiate between diamonds of the two para geneses. Carbon isotope ratios of these eclogitic and peridotitic diamonds were also measured. The comparison of this with the Cr/Sc ratios revealed that the carbon isotope ratios of both para geneses overlap in a narrow range and do not show the clear separations seen with Cr/Sc and Au/Ir ratios. It can be suggested, therefore, on the basis of the suite of 61 diamonds analyzed in this study, that the Cr/Sc and Au/Ir ratios are much more useful tools to distinguish between diamonds

  17. Scientific instruments, scientific progress and the cyclotron

    International Nuclear Information System (INIS)

    Baird, David; Faust, Thomas

    1990-01-01

    Philosophers speak of science in terms of theory and experiment, yet when they speak of the progress of scientific knowledge they speak in terms of theory alone. In this article it is claimed that scientific knowledge consists of, among other things, scientific instruments and instrumental techniques and not simply of some kind of justified beliefs. It is argued that one aspect of scientific progress can be characterized relatively straightforwardly - the accumulation of new scientific instruments. The development of the cyclotron is taken to illustrate this point. Eight different activities which promoted the successful completion of the cyclotron are recognised. The importance is in the machine rather than the experiments which could be run on it and the focus is on how the cyclotron came into being, not how it was subsequently used. The completed instrument is seen as a useful unit of scientific progress in its own right. (UK)

  18. Determination of uranium and thorium in rock samples from Harargaj Anticline by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Rahman, M.; Molla, N.I.; Sharif, A.K.M.; Basunia, S.; Islam, S.; Miah, R.U.; Hossain, S.M.; Chowdhury, M.I.; Bhuiyan, A.D.; Stegnar, P.

    1993-01-01

    Uranium and thorium were determined in geological materials such as radioactive rock samples collected from the Harargaj Anticline in Moulavi Bazar. The pure instrumental neutron activation analysis (INAA) technique was used in qualitative and quantitative analysis of the rock samples for U and Th. The samples were properly prepared together with their standards and simultaneously irradiated in a neutron flux of the order of 10 12 n*cm -2 *s -1 using the TRIGA MARK II research reactor facility at the AERE, Savar, Dhaka. After activation the samples were subjected to γ-ray spectrometry using a high purity germanium detection system. As a result of the analysis, U and Th could be determined. The data are consistent with the values reported by the ground radiometric survey group for some of the samples. (author) 7 refs.; 1 fig.; 2 tabs

  19. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  20. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  1. A review of instruments to measure interprofessional team-based primary care.

    Science.gov (United States)

    Shoemaker, Sarah J; Parchman, Michael L; Fuda, Kathleen Kerwin; Schaefer, Judith; Levin, Jessica; Hunt, Meaghan; Ricciardi, Richard

    2016-07-01

    Interprofessional team-based care is increasingly regarded as an important feature of delivery systems redesigned to provide more efficient and higher quality care, including primary care. Measurement of the functioning of such teams might enable improvement of team effectiveness and could facilitate research on team-based primary care. Our aims were to develop a conceptual framework of high-functioning primary care teams to identify and review instruments that measure the constructs identified in the framework, and to create a searchable, web-based atlas of such instruments (available at: http://primarycaremeasures.ahrq.gov/team-based-care/ ). Our conceptual framework was developed from existing frameworks, the teamwork literature, and expert input. The framework is based on an Input-Mediator-Output model and includes 12 constructs to which we mapped both instruments as a whole, and individual instrument items. Instruments were also reviewed for relevance to measuring team-based care, and characterized. Instruments were identified from peer-reviewed and grey literature, measure databases, and expert input. From nearly 200 instruments initially identified, we found 48 to be relevant to measuring team-based primary care. The majority of instruments were surveys (n = 44), and the remainder (n = 4) were observational checklists. Most instruments had been developed/tested in healthcare settings (n = 30) and addressed multiple constructs, most commonly communication (n = 42), heedful interrelating (n = 42), respectful interactions (n = 40), and shared explicit goals (n = 37). The majority of instruments had some reliability testing (n = 39) and over half included validity testing (n = 29). Currently available instruments offer promise to researchers and practitioners to assess teams' performance, but additional work is needed to adapt these instruments for primary care settings.

  2. Determination of trace elements in Turkish tea leaves by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Demiralp, R.

    1986-01-01

    The human body continuously assimilates a variety of inorganic elements from food and the environment. Some of these elements are closely related to human health and disorder. Tea is one of the most popular stimulating beverages which is consumed by low and high income family groups in many countries. Instrumental neutron activation analysis is one of the preferred methods because information on a large number of elements can be obtained simultaneously. Five packets each of the seven commonly used brands of tea were obtained from the market. In order to determine the transfer of trace elements into the drinkable portion about 2-3g. of the tea leaves were boiled in hot water for 2 min. After filtration the used tea leaves were dried at 65 deg. C in an oven and a portion, about 200mg was used for analysis. Samples and standards were irradiated 10 min. and 2 hrs. at pneumatic system and central thimble in the TRIGA MARK-II research reactor. After irradiation, the activities of samples and standards were measured with a aoaxial Ge detector coupled to a spectroscopic amplifier. A Canbera 90 model multi- channel analyzer with an 8K memory was used for pulse height analysis. The system has a resolution of 2.0 KeV. for the 1332.5 KeV gamma ray of 60 Co. The activity of the sample and standard was compared and the element contst of the sample was calculated. (author)

  3. The Development of an ASSA Module as an Auxiliary Tool for Assessment of Existing Plant Instrumentation and enhancement of the instruments performance

    International Nuclear Information System (INIS)

    Koo, Kil Mo; Kang, Kyung Ho; Ha, Kwang Soon; Cho, Young Ro; Cho, Young; Park, Rae Jun; Kim, Sang Baik; Kim, Hee Dong

    2007-04-01

    A review of a plant's accident management capabilities is one of the key elements in achieving regulatory closure of severe accident issues. During accidents, information and data from plant's instruments, as well as others sources, are essential for assessing the plant's status and response. Unlike for design basis accidents, there are inherently some uncertainties to instrumentation capabilities for severe accident conditions. There are many ways to obtain information during a severe accident. Moreover, precise measurements are not necessary. The redundancy and ruggedness of a plant's instrumentation provides considerable depth in the capability of existing designs. The circuit simulation analysis and diagnosis methods are used to assess instruments in detail when they give apparently abnormal readings. A new simulator, ASSA(abnormal signal simulator analysis), through an analysis of the important circuits modeling under severe accident conditions has been designed. It has three main functions which are a signal processing tool, an accident management tool, and an additional guide from the initial screen. In this paper, it can be simulated to the temperature characteristic analysis procedure of the ASSA through EQ data comparative method and using specific signal processing under severe accident condition

  4. Legal instruments for the promotion of a sustainable consumption. Using products as an example; Rechtliche Instrumente zur Foerderung des nachhaltigen Konsums. Am Beispiel von Produkten

    Energy Technology Data Exchange (ETDEWEB)

    Schlacke, Sabine; Stadermann, Michael; Grunow, Moritz [Forschungsstelle fuer Europaeisches Umweltrecht (FEU), Bremen (Germany)

    2012-06-15

    The expertise under consideration attempts to identify, to analyze and to develop further the legal instruments for the promotion of asustainable consumption. Legal possibilities of impacting the consumer behaviour in the utilization phase of products shall be highlighted in order to promote the sustainable consumption. The focus of this expertise are instruments directly aimed at consumers. The activation of these instruments shall effectuate a more sustainable behaviour of consumption.

  5. Number crunchers : instrumentation sector treads path of selective automation

    International Nuclear Information System (INIS)

    Budd, G.

    2006-01-01

    Automation guided by adequate monitoring and control instrumentation is playing an increasingly important role in the oil and gas sector. This article presented a overview of new instruments in the Western Canada Sedimentary Basin (WCSB), where a niche market for instrumentation and automation has grown in tandem with increased drilling activities. Fluctuating prices in oil and gas have also meant that available production methods must be optimized in order to ensure bottom line profits. However, economies of production scale can exclude extensive monitoring techniques in coalbed methane (CBM) activities. Compressor stations are the site of most monitoring and control instrumentation in CBM activities. Compressor packages at the stations include an engine panel that monitors suction pressure and water temperature. Alarm points on all monitoring instrumentation can shut down operations or assist in slight adjustments to machinery to optimize production. In addition, acoustical flow meters are fitted to headers to identify drops in a station's overall volumetric flow of natural gas. Instrumentation at the stations monitors and controls boilers that heat glycol for the gas dehydration process through the use of a pneumatic control loop that communicates with the motor control centre. The system is capable of ensuring shut-downs in emergencies. The combination of automation and carbon dioxide (CO 2 ) flooding has dramatically improved production in the Weyburn oilfield in southeastern Saskatchewan, where data transfer is now completed using Ethernet communications to a SCADA system to communicate with and from 5 satellite sites to a central main plant. It was estimated that the life expectancy of the Weyburn oilfield has been extended by almost 25 years. It was concluded that when harnessed to other technologies and combined with a user-friendly interface, automation can make a huge difference in the production profile of a field. 2 figs

  6. Determination of trace elements in Pre-Hispanic ceramics from Chile's Central Zone using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Andonie, O; Munoz, L; Kohnnenkamp, I; Falabella, F

    2000-01-01

    The determination of the element composition in archaeological ceramics is an often unexplored potential, that could provide a unique set of data to verify regional economic and socio-political hypotheses. By chemically defining the elements in these materials, their manufacturing and production centers may be identified, as well as the territorial and social organization of the peoples. Appropriate analytical methodologies for this type of research are limited since there are strict requirements with reference to precision, sensitivity and detection limits, all characteristics that the activation analysis technique provides. The Chilean Nuclear Energy Commission, the University of Chile, the Smithsonian Institution and the International Atomic Energy Agency developed together a cooperative interregional project to promote interdisciplinary research, to resolve archaeological problems and to develop a new application for a nuclear analytical technique. Until this work was undertaken, no systematic studies of trace elements in archaeological ceramics had been done in Chile using the technique of Instrumental Neutron Activation Analysis (INAA). This analytical technique was used in this research to chemically characterize archaeological pieces with the sensitivity, precision and accuracy needed to be able to work with mathematical models that can or cannot establish relationships between the different samples. Protocols were defined first for preparing the pottery samples in order to generate representative samples that could be analyzed by INAA. The homogeneity in preparing the samples used was defined using a group of elements that could be determined by INAA with a precision under 2%. A group of 18 elements was selected and an analytical test procedure was planned that included the type of packaging for the irradiation, the irradiation times, decline and count, the standards to be used and the type of monitor for correcting the neutron flow. The methodology used

  7. Integrated infrastructure initiatives for material testing reactor innovations

    International Nuclear Information System (INIS)

    Dekeyser, Jean; Vermeeren, Ludo; Iracane, Daniel

    2011-01-01

    Highlights: → The EU FP7 MTR+I3 project has initiated a durable cooperation between MTR operators. → Improvements in irradiation test device technology and instrumentation were achieved. → Professional training efforts were streamlined and best practices were exchanged. → A framework has been set up to coordinate and optimize the use of MTRs in the EU. - Abstract: The key goal of the European FP6 project MTR+I3 was to build a durable cooperation between Material Testing Reactor (MTR) operators and relevant laboratories that can maintain European leadership with updated capabilities and competences regarding reactor performances and irradiation technology. The MTR+I3 consortium was composed of 18 partners with a high level of expertise in irradiation-related services for all types of nuclear plants. This project covered activities that foster integration of the MTR community involved in designing, fabricating and operating irradiation devices through information exchange, know-how cross-fertilization, exchanges of interdisciplinary personnel, structuring of key-technology suppliers and professional training. The network produced best practice guidelines for selected irradiation activities. This project allowed to launch or to improve technical studies in various domains dealing with irradiation test device technology, experimental loop designs and instrumentation. Major results are illustrated in this paper. These concern in particular: on-line fuel power determination, neutron screen optimization, simulation of transmutation process, power transient systems, water chemistry and stress corrosion cracking, fission gas measurement, irradiation behaviour of electronic modules, mechanical loading under irradiation, high temperature gas loop technology, heavy liquid metal loop development and safety test instrumentation. One of the major benefits of this project is that, starting from a situation of fragmented resources in a strongly competitive sector, it has

  8. Initial Awareness as Perceived by a Group of Senior Students Majoring in High School Teaching in regards to their Own Teaching Process Focused on Assessment Activities

    Directory of Open Access Journals (Sweden)

    Gerardo Ignacio Sánchez-Sánchez

    2015-05-01

    Full Text Available Developed in a regional campus of a university located 200 miles south of Santiago de Chile, the research showed the initial awareness of 50 senior students majoring in three High School Teaching Training Programs: Spanish Language; History; and Math, in regards to their own teaching process The qualitative approach used in this research is supported by the grounded theory. The critical incident technique was used to obtain the information about the individuals mentioned above, after their first period as in-practice High School teachers. Results show that the assessment teaching functions are mostly mentioned as essential to improve their teaching activities focused on the learning process of high school students. However, Teacher Training Programs should also emphasize real challenges and the abilities that a teacher must successfully develop during the process, instead of mainly focusing on measurement instruments and theoretical outlines

  9. Proceedings: Instrumentation and control test reduction workshop

    International Nuclear Information System (INIS)

    1991-09-01

    Instrumentation and control (I ampersand C) surveillance and testing is a significant contributor to operations and management costs. Several techniques to eliminate or reduce manual testing requirements could reduce costs while improving plant safety and performance. I ampersand C test reduction was the subject of this 1991 workshop. The workshop covered test elimination, test reduction, test automation, and relevant standards and benefits. The conclusions of the workshop were the following: More utility information sharing is important. There is a significant amount of information available throughout the industry, but it is not available in a concise, useable form. An I ampersand C utility users group is needed to address items such as instrument calibration reduction, set-point methodologies, and other current I ampersand C issues. The workshop was well received. The timing is right to initiate actions to reduce testing

  10. Safeguards instrumentation: a computer-based catalog. Second edition

    International Nuclear Information System (INIS)

    Auerbach, C.

    1985-04-01

    This catalog contains entries on new developments and on items listed in BNL 51450, which have either been carried over unchanged or been updated. More than 70 entries were deleted because of either obsolescence, insufficient interest in terms of safeguards, or lack of documentable development activities in recent years. Some old listings as well as new material was consolidated into more generic entries. As in the earlier document, the emphasis is on devices and instruments that are either in field use at this time or under active development. A few items such as NDA reference materials, instrument vans and certain shipping containers are included because they are important adjuncts to optimum utilization of safeguards instrumentation. This catalog does not include devices for physical protection. As was the case with its predecessor, most of the material in this catalog originated in the US and Canada; a few contributions came from member states of the European Community

  11. Safeguards instrumentation: a computer-based catalog. Second edition

    Energy Technology Data Exchange (ETDEWEB)

    Auerbach, C.

    1985-04-01

    This catalog contains entries on new developments and on items listed in BNL 51450, which have either been carried over unchanged or been updated. More than 70 entries were deleted because of either obsolescence, insufficient interest in terms of safeguards, or lack of documentable development activities in recent years. Some old listings as well as new material was consolidated into more generic entries. As in the earlier document, the emphasis is on devices and instruments that are either in field use at this time or under active development. A few items such as NDA reference materials, instrument vans and certain shipping containers are included because they are important adjuncts to optimum utilization of safeguards instrumentation. This catalog does not include devices for physical protection. As was the case with its predecessor, most of the material in this catalog originated in the US and Canada; a few contributions came from member states of the European Community.

  12. MYC activation is a hallmark of cancer initiation and maintenance.

    Science.gov (United States)

    Gabay, Meital; Li, Yulin; Felsher, Dean W

    2014-06-02

    The MYC proto-oncogene has been implicated in the pathogenesis of most types of human tumors. MYC activation alone in many normal cells is restrained from causing tumorigenesis through multiple genetic and epigenetically controlled checkpoint mechanisms, including proliferative arrest, apoptosis, and cellular senescence. When pathologically activated in a permissive epigenetic and/or genetic context, MYC bypasses these mechanisms, enforcing many of the "hallmark" features of cancer, including relentless tumor growth associated with DNA replication and transcription, cellular proliferation and growth, protein synthesis, and altered cellular metabolism. MYC mandates tumor cell fate, by inducing stemness and blocking cellular senescence and differentiation. Additionally, MYC orchestrates changes in the tumor microenvironment, including the activation of angiogenesis and suppression of the host immune response. Provocatively, brief or even partial suppression of MYC back to its physiological levels of activation can result in the restoration of intrinsic checkpoint mechanisms, resulting in acute and sustained tumor regression, associated with tumor cells undergoing proliferative arrest, differentiation, senescence, and apoptosis, as well as remodeling of the tumor microenvironment, recruitment of an immune response, and shutdown of angiogenesis. Hence, tumors appear to be "addicted" to MYC because of both tumor cell-intrinsic, cell-autonomous and host-dependent, immune cell-dependent mechanisms. Both the trajectory and persistence of many human cancers require sustained MYC activation. Multiscale mathematical modeling may be useful to predict when tumors will be addicted to MYC. MYC is a hallmark molecular feature of both the initiation and maintenance of tumorigenesis. Copyright © 2014 Cold Spring Harbor Laboratory Press; all rights reserved.

  13. Initial insight into why physical activity may help prevent adolescent smoking uptake.

    Science.gov (United States)

    Audrain-McGovern, Janet; Rodriguez, Daniel; Cuevas, Jocelyn; Sass, Joseph

    2013-10-01

    Whereas research supports the importance of regular physical activity to decrease the likelihood of smoking uptake, the mechanisms accounting for this relationship are poorly understood. We sought to determine whether the enjoyment or reward derived from physical activity is one mechanism underlying the relationship between smoking and physical activity. The sample was composed of 1374 adolescents participating in a prospective longitudinal survey study of health behaviors. Variables were measured via self-report every six months for eight waves of data spanning four years. An associative processes latent growth curve model revealed a significant and negative indirect effect of baseline physical activity on baseline smoking through baseline physical activity reward (b(indirect)=-.18, z=-3.11, p=.002; 95% CI=-.29, -.07). Similarly, there was a significant and negative indirect effect of physical activity trend on smoking trend through physical activity reward trend (b(indirect)=-.16, z=-2.09, p=.04; 95% CI=-.30, -.01). The effect of physical activity on smoking at baseline and across time was completely mediated by physical activity reward. There was less support for the idea that smoking progression was associated with reduced physical activity reward and subsequent declines in physical activity. This study provides the first evidence implicating physical activity reward as one mechanism by which physical activity reduces the likelihood of adolescent smoking uptake. Smoking prevention interventions that promote physical activity and target physical activity enjoyment may have an important impact on adolescent smoking initiation and progression. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  14. Piezoelectrically Initiated Pyrotechnic Igniter

    Science.gov (United States)

    Quince, Asia; Dutton, Maureen; Hicks, Robert; Burnham, Karen

    2013-01-01

    This innovation consists of a pyrotechnic initiator and piezoelectric initiation system. The device will be capable of being initiated mechanically; resisting initiation by EMF, RF, and EMI (electromagnetic field, radio frequency, and electromagnetic interference, respectively); and initiating in water environments and space environments. Current devices of this nature are initiated by the mechanical action of a firing pin against a primer. Primers historically are prone to failure. These failures are commonly known as misfires or hang-fires. In many cases, the primer shows the dent where the firing pin struck the primer, but the primer failed to fire. In devices such as "T" handles, which are commonly used to initiate the blowout of canopies, loss of function of the device may result in loss of crew. In devices such as flares or smoke generators, failure can result in failure to spot a downed pilot. The piezoelectrically initiated ignition system consists of a pyrotechnic device that plugs into a mechanical system (activator), which on activation, generates a high-voltage spark. The activator, when released, will strike a stack of electrically linked piezo crystals, generating a high-voltage, low-amperage current that is then conducted to the pyro-initiator. Within the initiator, an electrode releases a spark that passes through a pyrotechnic first-fire mixture, causing it to combust. The combustion of the first-fire initiates a primary pyrotechnic or explosive powder. If used in a "T" handle, the primary would ramp the speed of burn up to the speed of sound, generating a shock wave that would cause a high explosive to go "high order." In a flare or smoke generator, the secondary would produce the heat necessary to ignite the pyrotechnic mixture. The piezo activator subsystem is redundant in that a second stack of crystals would be struck at the same time with the same activation force, doubling the probability of a first strike spark generation. If the first

  15. Instrumental neutron activation analysis of rib bone samples and of bone reference materials

    International Nuclear Information System (INIS)

    Saiki, M.; Takata, M.K.; Kramarski, S.; Borelli, A.

    2000-01-01

    The instrumental neutron activation analysis method was used for the determination of trace elements in rib bone samples taken from autopsies of accident victims. The elements Br, Ca, Cl, Cr, Fe, Mg, Mn, Na, P, Sr, Rb and Zn were determined in cortical tissues by using short and long irradiations with thermal neutron flux of the IEA-R1m nuclear reactor. The reference materials NIST SRM 1400 Bone Ash and NIST SRM 1486 Bone Meal were also analyzed in order to evaluate the precision and the accuracy of the results. It was verified that lyophilization is the most convenient process for drying bone samples since it does not cause any element losses. Comparisons were made between the results obtained for rib samples and the literature values as well as between the results obtained for different ribs from a single individual and for bones from different individuals. (author)

  16. Determination of selenium and zinc in rat plasma by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Munoz A, Luis.

    1997-01-01

    To evaluate the effects on the thyroid function when simple or multiple zinc, selenium and iodine deficiency are induced, research was carried out in laboratory animals. For simultaneously determining the Zn and Se concentration in rat plasma, an instrumental neutron activation analysis technique was applied. A clean laboratory, was used for the preparation of samples. High purity materials were used for sample collection and storage. Irradiation, decay and counting parameters were optimized to obtain the best sensitivity, accuracy and precision analysis. The Zn and Se concentrations were determined from the peak area of gamma-rays of 1115 and 265 KeV respectively. The analytical methodology used was validated with standard reference materials. The procedure used for the analysis, including the phases of collection, treatment of the samples and analytical determination was considered suitable for the study of trace elements in biological samples, especially plasma. (author) [es

  17. Vision though afocal instruments: generalized magnification and eye-instrument interaction

    Science.gov (United States)

    Harris, William F.; Evans, Tanya

    2018-04-01

    In Gaussian optics all observers experience the same magnification, the instrument's angular magnification, when viewing distant objects though a telescope or other afocal instruments. However, analysis in linear optics shows that this is not necessarily so in the presence of astigmatism. Because astigmatism may distort and rotate images it is appropriate to work with generalized angular magnification represented by a 2 × 2 matrix. An expression is derived for the generalized magnification for an arbitrary eye looking through an arbitrary afocal instrument. With afocal instruments containing astigmatic refracting elements not all eyes experience the same generalized magnification; there is interaction between eye and instrument. Eye-instrument interaction may change as the instrument is rotated about its longitudinal axis, there being no interaction in particular orientations. A simple numerical example is given. For sake of completeness, expressions for generalized magnification are also presented in the case of instruments that are not afocal and objects that are not distant.

  18. Development and evaluation of the Korean Health Literacy Instrument.

    Science.gov (United States)

    Kang, Soo Jin; Lee, Tae Wha; Paasche-Orlow, Michael K; Kim, Gwang Suk; Won, Hee Kwan

    2014-01-01

    The purpose of this study is to develop and validate the Korean Health Literacy Instrument, which measures the capacity to understand and use health-related information and make informed health decisions in Korean adults. In Phase 1, 33 initial items were generated to measure functional, interactive, and critical health literacy with prose, document, and numeracy tasks. These items included content from health promotion, disease management, and health navigation contexts. Content validity assessment was conducted by an expert panel, and 11 items were excluded. In Phase 2, the 22 remaining items were administered to a convenience sample of 292 adults from community and clinical settings. Exploratory factor and item difficulty and discrimination analyses were conducted and four items with low discrimination were deleted. In Phase 3, the remaining 18 items were administered to a convenience sample of 315 adults 40-64 years of age from community and clinical settings. A confirmatory factor analysis was performed to test the construct validity of the instrument. The Korean Health Literacy Instrument has a range of 0 to 18. The mean score in our validation study was 11.98. The instrument exhibited an internal consistency reliability coefficient of 0.82, and a test-retest reliability of 0.89. The instrument is suitable for screening individuals who have limited health literacy skills. Future studies are needed to further define the psychometric properties and predictive validity of the Korean Health Literacy Instrument.

  19. Dynamic Measurement of Disease Activity in Acute Pancreatitis: The Pancreatitis Activity Scoring System.

    Science.gov (United States)

    Wu, Bechien U; Batech, Michael; Quezada, Michael; Lew, Daniel; Fujikawa, Kelly; Kung, Jonathan; Jamil, Laith H; Chen, Wansu; Afghani, Elham; Reicher, Sonya; Buxbaum, James; Pandol, Stephen J

    2017-07-01

    Acute pancreatitis has a highly variable course. Currently there is no widely accepted method to measure disease activity in patients hospitalized for acute pancreatitis. We aimed to develop a clinical activity index that incorporates routine clinical parameters to assist in the measurement, study, and management of acute pancreatitis. We used the UCLA/RAND appropriateness method to identify items for inclusion in the disease activity instrument. We conducted a systematic literature review followed by two sets of iterative modified Delphi meetings including a panel of international experts between November 2014 and November 2015. The final instrument was then applied to patient data obtained from five separate study cohorts across Southern California to assess profiles of disease activity. From a list of 35 items comprising 6 domains, we identified 5 parameters for inclusion in the final weighted clinical activity scoring system: organ failure, systemic inflammatory response syndrome, abdominal pain, requirement for opiates and ability to tolerate oral intake. We applied the weighted scoring system across the 5 study cohorts comprising 3,123 patients. We identified several distinct patterns of disease activity: (i) overall there was an elevated score at baseline relative to discharge across all study cohorts, (ii) there were distinct patterns of disease activity related to duration of illness as well as (iii) early and persistent elevation of disease activity among patients with severe acute pancreatitis defined as persistent organ failure. We present the development and initial validation of a clinical activity score for real-time assessment of disease activity in patients with acute pancreatitis.

  20. Evaluating a questionnaire to measure improvement initiatives in Swedish healthcare

    Directory of Open Access Journals (Sweden)

    Andersson Ann-Christine

    2013-02-01

    Full Text Available Abstract Background Quality improvement initiatives have expanded recently within the healthcare sector. Studies have shown that less than 40% of these initiatives are successful, indicating the need for an instrument that can measure the progress and results of quality improvement initiatives and answer questions about how quality initiatives are conducted. The aim of the present study was to develop and test an instrument to measure improvement process and outcome in Swedish healthcare. Methods A questionnaire, founded on the Minnesota Innovation Survey (MIS, was developed in several steps. Items were merged and answer alternatives were revised. Employees participating in a county council improvement program received the web-based questionnaire. Data was analysed by descriptive statistics and correlation analysis. The questionnaire psychometric properties were investigated and an exploratory factor analysis was conducted. Results The Swedish Improvement Measurement Questionnaire consists of 27 items. The Improvement Effectiveness Outcome dimension consists of three items and has a Cronbach’s alpha coefficient of 0.67. The Internal Improvement Processes dimension consists of eight sub-dimensions with a total of 24 items. Cronbach’s alpha coefficient for the complete dimension was 0.72. Three significant item correlations were found. A large involvement in the improvement initiative was shown and the majority of the respondents were satisfied with their work. Conclusions The psychometric property tests suggest initial support for the questionnaire to study and evaluate quality improvement initiatives in Swedish healthcare settings. The overall satisfaction with the quality improvement initiative correlates positively to the awareness of individual responsibilities.

  1. Comparison of Elemental Composition in Korean Irradiated Foods using Instrumental Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Kim, Sun Ha; Sun, Gwang Min; Lim, Jong Myung; Moon, Jong Hwa; Lee, Kye Hong; Kim, Young Jin; Choi, Jong Il; Lee, Joo Eun

    2010-01-01

    The information and role of trace mineral elements from an intake of created and processed foodstuff are important as a indicator of human health and nutritional parameter, as well as a quality control of food and diet. Particularly, special food created for consumption by astronauts in outer space may differ with common food on the earth in order to compensate a decrease of taste and nutrition by strong cosmic rays, a state of nongravitation, low pressure, and enclosed space environment. In April 2008, Korea's first astronaut became a crew member of the international space station and she was brought special space versions of Korea's national dishes such as Kimchi, boiled rice, hot red paste, green tea, ramyun, and so on. Accurate quantitative analysis of trace elements in various kinds of biological samples is also important for data quality. Neutron activation analysis is a sensitive, non-destructive, multi-elemental analytical method, and is proper for tracing elements in a biological sample in order to avoid loss and contamination by chemical pretreatment. This study analyses the distribution of concentrations for both essential and toxic elements in six kinds of Korean space foods developed by KAERI. The quantitative analytical results from instrumental neutron activation analysis are presented

  2. Predicting the initial freezing point and water activity of meat products from composition data

    NARCIS (Netherlands)

    Sman, van der R.G.M.; Boer, E.P.J.

    2005-01-01

    In this paper we predict the water activity and initial freezing point of food products (meat and fish) based on their composition. The prediction is based on thermodynamics (the Clausius-Clapeyron equation, the Ross equation and an approximation of the Pitzer equation). Furthermore, we have taken

  3. Characteristic Elemental Composition of Oil Pigments using Instrumental Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yong Sam; Kim, Sun Ha; Sun, Gwang Min; Lim, Jong Myung; Moon, Jong Hwa; Kim, Young Jin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lim, Sung Jin; Song, Yu Na; Kim, Ken [National Museum of Contemporary Art, Gwacheon (Korea, Republic of)

    2009-10-15

    The principal aim of this study is to identify the applicability of instrumental neutron activation analysis as a non-destructive examination tool for the quantitative composition analysis associated with authentication, restoration, and conservation of art objects in the field of cultural heritage. Generally, the chemical composition of pigments are associated with the colors such as white, yellow, orange, red, green, blue and black, and it varies with raw materials of pigments. According to the colors of a different pigments, chemical compositions are as follows; for example, white pigments were used for a mixture of Pb(CO{sub 3}){sub 2}, PbSO{sub 4}, PbO, Pb(OH){sub 2}, ZnO, ZnS, TiO{sub 2}, BaSO{sub 4}, CaCO{sub 3}, Al{sub 2}O{sub 3}, As{sub 2}S{sub 3}, etc.; black pigments were series of carbon black, borne ash, MnO+Mn{sub 2}O{sub 3}, etc.; red pigments were Fe{sub 2}O{sub 3}, Pb{sub 3}O{sub 4}, HgS, PbMo{sub 4}, CdS+CdSe, etc.; brown and yellow pigments were PbCrO{sub 4}, ZnCrO{sub 4}, CdS-ZnS, K{sub 3}[Co(NO{sub 2}){sub 6}], Pb(SbO{sub 3}){sub 2}, C{sub 19}H{sub 16}O{sub 11}Mg, SrCrO{sub 4}, etc.; green pigments were Cr{sub 2}O{sub 3}, Cr{sub 2}O(OH){sub 4}, Cu(C{sub 2}H{sub 3}O{sub 2})-2Cu(OH){sub 2}), Cr{sub 2}O{sub 3}-Al{sub 2}O{sub 3}-CoO, etc.; blue pigments were Fe{sub 4}[Fe(CN){sub 6}]{sub 3}, CoO-Al{sub 2}O{sub 3}, Na{sub 8}-{sub 10}Al{sub 6}Si{sub 6}O{sub 24}S{sub 2-4}, etc. This first step is to obtain quantitative data on the concentrations of major, minor and trace elements in oil pigments and to explain pigment sources by statistical treatment as reported in many literatures. The determination of major, minor and micro elements in the subject materials are essential in many fields of basic science and technology as well as commercial and industrial fields. In particular, direct analysis of a sample offers a more effective investigation method in these fields. Instrumental neutron activation analysis (INAA) has an inherent advantage of being a

  4. Air pollution monitoring of an urban dust in Daejeon city, Korea by using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Yong-Sam Chung; Sun-Ha Kim; Jong-Hwa Moon; Hark-Rho Kim; Jong-Myoung Lim; Jin-Hong Lee

    2008-01-01

    For air pollution monitoring, about 1300 airborne particulate matter samples were collected by using a low volume air sampler and a polycarbonate filter at two sampling sites in an urban region, Daejeon, the middle of Korea from 2003 to 2006. Mass concentrations of the black carbon were measured using a smoke stain reflectometer. The concentrations of 24 elements in the collected samples were analyzed by using instrumental neutron activation analysis, and its temporal trends and enrichment factors were investigated under different environmental conditions. Analytical control was carried out by using certified reference materials. (author)

  5. Instrumental neutron activation analysis in study of the toxicity of trialkyltin-methacrylic copolymer as an antifouling agent

    International Nuclear Information System (INIS)

    Lin, S.M.; Ching, C.H.; Tseng, C.L.; Yang, M.H.

    1985-01-01

    The analysis of tin in biological materials is rarely reported. In this study instrumental neutron activation analysis was used to determine the tin together with some other trace elements in various organs of rats treated with trialkyltin-methacrylic copolymer. No appreciable accumulation of tin and variation of distribution of trace elements (Cr, Fe, Zn and Co) in various organs were found. The pathological changes in the liver sections can not be observed either. This, therefore, indicates that the toxicity of trialkyltin-methacrylic copolymer is low, if any. (author)

  6. RELEVANCE OF ECONOMIC INSTRUMENTS USED IN SUSTAINABLE DEVELOPMENT PROCESS

    Directory of Open Access Journals (Sweden)

    SORINA-GEANINA MĂRGĂRIT (STĂNESCU

    2011-01-01

    Full Text Available The interaction between environmental, economic and social factors influences the ecological balance and generates the change of living conditions and those of socio-economic development. One of the essential conditions for building a sustainable economic development is the identification and implementation of active or voluntary instruments to influence economic and social activity towards ensuring their sustainability. In this paper, we intend to introduce the tools used in the process of sustainable development, which have a key role in adopting an environmentally responsible behavior. The results of this study are represented by the drafting of the advantages and disadvantages of using these economic and financial instruments. The purpose of this paper is to present the evolution of costs for environmental protection and the relevance of instruments used at the national level in environmental protection.

  7. Initial evaluation of psychometric properties of a structured work task application for the Assessment of Work Performance in a constructed environment.

    Science.gov (United States)

    Karlsson, Elin A; Liedberg, Gunilla M; Sandqvist, Jan L

    2017-06-22

    The Swedish Social Insurance Administration has developed a new assessment tool for sickness insurance. This study is a part of the initial evaluation of the application, called the Assessment of Work Performance, Structured Activities, and focuses on evaluation of the psychometric properties of social validity, content validity, and utility. This was a qualitative study using semi-structured telephone interviews with occupational therapists. A convenience sample was used and participants who fulfilled inclusion criteria (n = 15) were interviewed. Data were analyzed using content analysis with a directed approach. The results indicate that the application provides valuable information and that it is socially valid. Assessors found work tasks suitable for a diverse group of clients and reported that clients accepted the assessments. Improvements were suggested, for example, expanding the application with more work tasks. The instrument has benefits; however, further development is desired. The use of a constructed environment in assessments may be a necessary option to supplement a real environment. But depending on organizational factors such as time and other resources, the participants had different opportunities to do so. Further evaluations regarding ecological validity are essential to ensure that assessments are fair and realistic when using constructed environments. Implications for rehabilitation This study indicates that assessment in a constructed environment can provide a secure and protected context for clients being assessed. Psychometric evaluations are a never-ending process and this assessment instrument needs further development. However, this initial evaluation provides guidance in development of the instrument but also what studies to give priority to. It is important to evaluate social validity in order to ensure that clients and assessors perceive assessment methods fair and meaningful. In this study, participants found the work tasks

  8. Microfluidic Apps for off-the-shelf instruments.

    Science.gov (United States)

    Mark, Daniel; von Stetten, Felix; Zengerle, Roland

    2012-07-21

    Within the last decade a huge increase in research activity in microfluidics could be observed. However, despite several commercial success stories, microfluidic chips are still not sold in high numbers in mass markets so far. Here we promote a new concept that could be an alternative approach to commercialization: designing microfluidic chips for existing off-the-shelf instruments. Such "Microfluidic Apps" could significantly lower market entry barriers and provide many advantages: developers of microfluidic chips make use of existing equipment or platforms and do not have to develop instruments from scratch; end-users can profit from microfluidics without the need to invest in new equipment; instrument manufacturers benefit from an expanded customer base due to the new applications that can be implemented in their instruments. Microfluidic Apps could be considered as low-cost disposables which can easily be distributed globally via web-shops. Therefore they could be a door-opener for high-volume mass markets.

  9. The digital reactor protection system for the instrumentation and control of reactor TRIGA PUSPATI (RTP)

    International Nuclear Information System (INIS)

    Nurfarhana Ayuni Joha; Izhar Abu Hussin; Mohd Idris Taib; Zareen Khan Abdul Jalil Khan

    2010-01-01

    Reactor Protection System (RPS) is important for Reactor Instrumentation and Control System. The RPS comprises all redundant electrical devices and circuitry involved in the generation of those initiating signals associated to the trip protective function. The instrumentation system for the RPS provides automatic protection signals against unsafe and improper reactor operation. The physical separation is provided for all of the redundant instrumentation systems to preserve redundancy. The safety protection systems using circuits composed of analog instruments and relays with relay contacts is difficult to realize from various reasons. Therefore, an application of digital technology can be said a logical conclusion also in the light of its functional superiority. (author)

  10. Determination of zinc concentration in female reproductive system by instrumental neutron activation

    International Nuclear Information System (INIS)

    Carvalho, Fernando Ramos de

    2009-01-01

    Non-surgical female sterilization through the transcervical insertion of quinacrine pellets was considered a definitive, low-cost, safe and effective contraceptive method. The zinc, present in both uterus and Fallopian tubes, inhibit the quinacrine efficiency. The addition of copper increases the efficacy of quinacrine, reducing the risk of pregnancy due to the failure to obstruct the Fallopian tubes. The copper neutralized the deleterious effect of the zinc and so the treatment efficacy is increased. In order to obtain a mapping to study the zinc content in the female reproductive system, samples of both uterus and Fallopian tubes were analyzed by instrumental neutron activation. The results show that, on average, the obtained zinc concentrations in tubes (89 μg-g -1 ) is lower than in the uterus (118 μg-g -1 ), confirming results obtained by other authors. These results will support a research project about non-surgical female sterilization of the 'Faculdade de Medicina da Universidade Federal de Minas Gerais' (Medical School of Federal University of Minas Gerais). The used methodology and obtained results are here reported. (author)

  11. Determination of zinc concentration in female reproductive system by instrumental neutron activation

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Fernando Ramos de, E-mail: framosc@oi.com.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear; Oliveira, Arno Heeren de, E-mail: heeren@nuclear.ufmg.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Faculdade de Medicina. Dept. de Ginecologia e Obstetricia; Ferreira, Claudia R.C.; Ferreira, Ricardo Alberto Neto; Menezes, Maria Angela de B.C., E-mail: claudia@medicina.ufmg.b, E-mail: ranf@cdtn.b, E-mail: menezes@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2009-07-01

    Non-surgical female sterilization through the transcervical insertion of quinacrine pellets was considered a definitive, low-cost, safe and effective contraceptive method. The zinc, present in both uterus and Fallopian tubes, inhibit the quinacrine efficiency. The addition of copper increases the efficacy of quinacrine, reducing the risk of pregnancy due to the failure to obstruct the Fallopian tubes. The copper neutralized the deleterious effect of the zinc and so the treatment efficacy is increased. In order to obtain a mapping to study the zinc content in the female reproductive system, samples of both uterus and Fallopian tubes were analyzed by instrumental neutron activation. The results show that, on average, the obtained zinc concentrations in tubes (89 mug-g{sup -1}) is lower than in the uterus (118 mug-g{sup -1}), confirming results obtained by other authors. These results will support a research project about non-surgical female sterilization of the 'Faculdade de Medicina da Universidade Federal de Minas Gerais' (Medical School of Federal University of Minas Gerais). The used methodology and obtained results are here reported. (author)

  12. Assessing Minimum Competencies of Beginning Teachers: Instrumentation, Measurement Issues, Legal Concerns.

    Science.gov (United States)

    Ellett, Chad D.

    An overview is presented of a performance-based assessment system, Teacher Performance Assessment Instruments (TPAI), developed by the Teacher Assessment Project at the University of Georgia to measure competencies of beginning teachers for initial professional certification. To clearly separate the preparation and certification functions within…

  13. Adding delayed recall to the ADAS-cog improves measurement precision in mild Alzheimer's disease: Implications for predicting instrumental activities of daily living.

    Science.gov (United States)

    Lowe, Deborah A; Balsis, Steve; Benge, Jared F; Doody, Rachelle S

    2015-12-01

    As research increasingly focuses on preclinical stages of Alzheimer's disease (AD), instruments must be retooled to identify early cognitive markers of AD. A supplemental delayed recall subtest for the Alzheimer's Disease Assessment Scale-cognitive (ADAS-cog; Mohs, Rosen, & Davis, 1983; Rosen, Mohs, & Davis, 1984) is commonly implemented, but it is not known precisely where along the spectrum of cognitive dysfunction this subtest yields incremental information beyond what is gained from the standard ADAS-cog, or whether it can improve prediction of functional outcomes. An item response theory approach can analyze this in a psychometrically rigorous way. Seven hundred eighty-eight patients with AD or amnestic complaints or impairment completed a battery including the ADAS-cog and 2 activities of daily living measures. The delayed recall subtest slightly improved the ADAS-cog's measurement precision in the mild range of cognitive dysfunction and increased prediction of instrumental activities of daily living for individuals with subjective memory impairment. (c) 2015 APA, all rights reserved).

  14. High degree modes and instrumental effects

    Energy Technology Data Exchange (ETDEWEB)

    Korzennik, S G [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA (United States); Rabello-Soares, M C; Schou, J [Stanford University, Stanford, CA (United States)], E-mail: skorzennik@cfa.harvard.edu

    2008-10-15

    Full-disk observations taken with the Michelson Doppler Imager (MDI) on board the Solar and Heliospheric Observatory (SOHO) spacecraft, or the upgraded Global Oscillations Network Group (GONG) instruments, have enough spatial resolution to resolve modes up to {iota} = 1000 if not {iota} = 1500. The inclusion of such high-degree modes (i.e., {iota} {<=} 1000) improves dramatically inferences near the surface. Unfortunately, observational and instrumental effects cause the characterization of high degree modes to be quite complicated. Indeed, the characteristics of the solar acoustic spectrum are such that, for a given order, mode lifetimes get shorter and spatial leaks get closer in frequency as the degree of a mode increases. A direct consequence of this property is that individual modes are resolved only at low and intermediate degrees. At high degrees the individual modes blend into ridges and the power distribution of the ridge defines the ridge central frequency, masking the underlying mode frequency. An accurate model of the amplitude of the peaks that contribute to the ridge power distribution is needed to recover the underlying mode frequency from fitting the ridge. We present a detailed discussion of the modeling of the ridge power distribution, and the contribution of the various observational and instrumental effects on the spatial leakage, in the context of the MDI instrument. We have constructed a physically motivated model (rather than an ad hoc correction scheme) that results in a methodology that can produce unbiased estimates of high-degree modes. This requires that the instrumental characteristics are well understood, a task that has turned out to pose a major challenge. We also present our latest results, where most of the known instrumental and observational effects that affect specifically high-degree modes were removed. These new results allow us to focus our attention on changes with solar activity. Finally, we present variations of mode

  15. Young Learners: An Examination of the Psychometric Properties of the Early Literacy Knowledge and Skills Instrument

    Science.gov (United States)

    Chan, Man Ching Esther

    2015-01-01

    The Early Literacy Knowledge and Skills (ELKS) instrument was informed by the work of Ferreiro and Teberosky based on the notion that young children could be differentiated according to levels of sophistication in their understanding of the rules of written language. As an initial step to evaluate the instrument for teaching purposes, the present…

  16. Early initiation of sexual activity: a risk factor for sexually transmitted diseases, HIV infection, and unwanted pregnancy among university students in China

    Directory of Open Access Journals (Sweden)

    Ravari Shahrzad

    2009-04-01

    Full Text Available Abstract Background To explore any association between the timing of the initiation of sexual activity and sexual behaviors and risks among university students in China. Methods Data were derived from a cross-sectional study on sexual behavior among university students conducted in Ningbo municipality, China, at the end of 2003. Students completed a self-administered, structured questionnaire. Of 1981 sexually active male students, 1908 (96.3% completed the item for timing of the initiation of sexual activity and were included in bivariate trend analyses and multiple logistic regression analyses to compare the association between this timing and sexual behavior and risks. Results Male early sexual initiators had a significantly higher risk profile, including a significantly higher proportion reporting non-regular partners (i.e., casual or commercial partners, multiple partners, diagnosis with a sexually transmitted disease (STD, partner history of pregnancy, partner history of induced abortion, and less condom and oral contraceptive use, compared with late initiators. Multivariate analyses confirmed the increased likelihood of these risks in early initiators versus late initiators, other than partner type during the last year. Conclusion Our results showed that, compared to late initiators, people who initiated sexual activity early engaged in more risky behaviors that could lead to elevated risks of unwanted pregnancies and STDs or human immunodeficiency virus infection. Sex-education strategies should be focused on an earlier age, should include advice on delaying the age of first sexual activity, and should target young people who continue to take sexual risks.

  17. Pancreatitis Quality of Life Instrument: Development of a new instrument

    Directory of Open Access Journals (Sweden)

    Wahid Wassef

    2014-02-01

    Full Text Available Objectives: The goal of this project was to develop the first disease-specific instrument for the evaluation of quality of life in chronic pancreatitis. Methods: Focus groups and interview sessions were conducted, with chronic pancreatitis patients, to identify items felt to impact quality of life which were subsequently formatted into a paper-and-pencil instrument. This instrument was used to conduct an online survey by an expert panel of pancreatologists to evaluate its content validity. Finally, the modified instrument was presented to patients during precognitive testing interviews to evaluate its clarity and appropriateness. Results: In total, 10 patients were enrolled in the focus groups and interview sessions where they identified 50 items. Once redundant items were removed, the 40 remaining items were made into a paper-and-pencil instrument referred to as the Pancreatitis Quality of Life Instrument. Through the processes of content validation and precognitive testing, the number of items in the instrument was reduced to 24. Conclusions: This marks the development of the first disease-specific instrument to evaluate quality of life in chronic pancreatitis. It includes unique features not found in generic instruments (economic factors, stigma, and spiritual factors. Although this marks a giant step forward, psychometric evaluation is still needed prior to its clinical use.

  18. Plasma-activated medium (PAM) kills human cancer-initiating cells.

    Science.gov (United States)

    Ikeda, Jun-Ichiro; Tanaka, Hiromasa; Ishikawa, Kenji; Sakakita, Hajime; Ikehara, Yuzuru; Hori, Masaru

    2018-01-01

    Medical non-thermal plasma (NTP) treatments for various types of cancers have been reported. Cells with tumorigenic potential (cancer-initiating cells; CICs) are few in number in many types of tumors. CICs efficiently eliminate anti-cancer chemicals and exhibit high-level aldehyde dehydrogenase (ALDH) activity. We previously examined the effects of direct irradiation via NTP on cancer cells; even though we targeted CICs expressing high levels of ALDH, such treatment affected both non-CICs and CICs. Recent studies have shown that plasma-activated medium (PAM) (culture medium irradiated by NTP) selectively induces apoptotic death of cancer but not normal cells. Therefore, we explored the anti-cancer effects of PAM on CICs among endometrioid carcinoma and gastric cancer cells. PAM reduced the viability of cells expressing both low and high levels of ALDH. Combined PAM/cisplatin appeared to kill cancer cells more efficiently than did PAM or cisplatin alone. In a mouse tumor xenograft model, PAM exerted an anti-cancer effect on CICs. Thus, our results suggest that PAM effectively kills both non-CICs and CICs, as does NTP. Therefore, PAM may be a useful new anti-cancer therapy, targeting various cancer cells including CICs. © 2017 Japanese Society of Pathology and John Wiley & Sons Australia, Ltd.

  19. Dioxin Exposure Initiative

    Science.gov (United States)

    The Dioxin Exposure Initiative (DEI) is no longer active. This page contains a summary of the dioxin exposure initiative with illustrations, contact and background information.Originally supported by scientist Matthew Lorber, who retired in Mar 2017.

  20. Local learning-networks on energy efficiency in industry - Successful initiative in Germany

    International Nuclear Information System (INIS)

    Jochem, Eberhard; Gruber, Edelgard

    2007-01-01

    Profitable energy-efficiency potentials are often not exploited in industry since management tends not to focus on energy issues. Sharing experiences between companies reveals possibilities for reducing the transaction costs involved. For this purpose, regionally or locally-organised learning networks of companies have been established. Social mechanisms are used to motivate management to pay more attention to energy efficiency in Switzerland and Germany. The main elements of the activities include initial consultation for each company with an experienced engineer, agreement on a common target for energy-efficiency improvement, regular meetings with technical presentations and an exchange of experiences, yearly control of energy consumption and CO 2 emissions as well as scientific monitoring and evaluation of the process. The results of some evaluations show that substantial progress has been made in implementing organisational measures and investments in energy efficiency in the participating companies. The reasons for these achievements are discussed and conclusions drawn about the opportunities and limits of this instrument. Finally, a recommendation is made to implement this instrument on a broader level

  1. Long range radio tracking of sea turtles and polar bear: Instrumentation and preliminary results

    Science.gov (United States)

    Baldwin, H. A.

    1972-01-01

    Instrumentation developed for studies of path behavior of the green sea turtle and migration movement of polar bear is described. Preliminary results bearing on navigation ability in these species are presented. Both species operate in difficult environments, and the problems faced in the design of electronic instrumentation for these studies are not completely specified at this time. However, the critical factors yet to be understood are primarily related to the behavior of instrumented animals. The data obtained with these experimental techniques are included, first to illustrate the technique and, second to provide initial preliminary results bearing on animal navigation.

  2. RASOR: an advanced instrument for soft x-ray reflectivity and diffraction.

    Science.gov (United States)

    Beale, T A W; Hase, T P A; Iida, T; Endo, K; Steadman, P; Marshall, A R; Dhesi, S S; van der Laan, G; Hatton, P D

    2010-07-01

    We report the design and construction of a novel soft x-ray diffractometer installed at Diamond Light Source. The beamline endstation RASOR is constructed for general users and designed primarily for the study of single crystal diffraction and thin film reflectivity. The instrument is comprised of a limited three circle (theta, 2theta, and chi) diffractometer with an additional removable rotation (phi) stage. It is equipped with a liquid helium cryostat, and post-scatter polarization analysis. Motorized motions are provided for the precise positioning of the sample onto the diffractometer center of rotation, and for positioning the center of rotation onto the x-ray beam. The functions of the instrument have been tested at Diamond Light Source, and initial test measurements are provided, demonstrating the potential of the instrument.

  3. The determination, by instrumental neutron-activation analysis, of some elements in the NIMROC standard reference materials

    International Nuclear Information System (INIS)

    Eddy, B.T.; Pearton, D.C.G.; Bibby, D.M.

    1975-01-01

    Instrumental neutron-activation analysis was used for the determination of sixteen trace and minor elements in the six NIMROC reference materials. Six reference rock materials prepared by the U.S. Geological Survey were also analysed, and the results were compared with the recommended, average, or magnitude values given for these rocks by Flanagan. The agreement between the two sets of results was found to be generally good, indicating that INAA is an acceptable technique for the determination of most of these elements. The values found for the NIMROC samples represent a significant contribution to the evaluation of the trace elements in these reference materials [af

  4. Determination of Li, B, and F by rapid instrumental neutron activation analysis using beta-particle counting

    International Nuclear Information System (INIS)

    Schmidt, J.O.; Palgaard, L.; Gwozdz, R.; Belhage, L.O.

    1984-01-01

    For the simultaneous determination of Li, B, and F, the application of rapid instrument neutron activation analysis was studied using 1.5s of irradiation and β-particle counting of 8 Li, 12 B, and 20 F. The fast transfer facility, Mach-1, the counting equipment, a 4-channel multiplexer, and a time-base controller are discussed. Further, the technique of simultaneous decay curve analysis of three successive decays is presented and quality control by residual analysis is demonstrated. Finally, analytical results are presented of the NBS-environmental standards Coal-1632a and Coal-1635, and of three BCR-coals intended as references materials

  5. ASIC and HMC designs for portable nuclear instruments

    International Nuclear Information System (INIS)

    Chandratre, V.B.

    2005-01-01

    This paper describes the seed activity done so far for realizing the goal of compact portable nuclear instruments and related instrumentation that can be designed, developed and manufactured without external constraints. This important activity requires critical components to be made in the country by tapping and gearing the established industrial units for this activity. A good deal of ground work has been carried out over a period of time in setting up IC design facility and CAD-FAB interface. There has been a close interaction with the production and semiconductor facilities to design and develop ASIC, hybrids, display devices, detectors/sensors etc. Efforts are also undertaken to develop the critical technologies that are required to fulfill the requirement. A status report on various technologies, ASIC, hybrids and their application development done in the face of out-standing challenges is being presented here. (author)

  6. Factoring - financial instrument supporting the current activity of an enterprise

    Directory of Open Access Journals (Sweden)

    Dorota Czerwińska-Kayzer

    2009-01-01

    Full Text Available Small and medium enterprises have a difficult access to classic financial sources. Therefore the factoring could be a financial instrument supporting effective management of the liabilities. Factoring improves the financial situation of a company, first of all financial liquidity. Moreover, factoring improves structure of financial statement and creates a possibility of risk transfer of debtor insolvency on factor.

  7. Design of a Channel Error Simulator using Virtual Instrument Techniques for the Initial Testing of TCP/IP and SCPS Protocols

    Science.gov (United States)

    Horan, Stephen; Wang, Ru-Hai

    1999-01-01

    There exists a need for designers and developers to have a method to conveniently test a variety of communications parameters for an overall system design. This is no different when testing network protocols as when testing modulation formats. In this report, we discuss a means of providing a networking test device specifically designed to be used for space communications. This test device is a PC-based Virtual Instrument (VI) programmed using the LabVIEW(TM) version 5 software suite developed by National Instruments(TM)TM. This instrument was designed to be portable and usable by others without special, additional equipment. The programming was designed to replicate a VME-based hardware module developed earlier at New Mexico State University (NMSU) and to provide expanded capabilities exceeding the baseline configuration existing in that module. This report describes the design goals for the VI module in the next section and follows that with a description of the design of the VI instrument. This is followed with a description of the validation tests run on the VI. An application of the error-generating VI to networking protocols is then given.

  8. Determination of arsenic and mercury in facial cosmetics by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Bravo Martinez, J.

    1979-01-01

    The presence of arsenic and mercury in some chilean facial cosmetics was investiged. Since in Chile there is no regulations dealing with the maximum permisible concentration of some chemical elements in cosmetics products, the national industry control neither the presence nor the quantity, if any, of those elements. The study was performed on compact or powder eye shadows by means of instrumental neutron activation analysis. The samples were analized without any chemical treatment and with minimum manipulation to avoid any possible contamination. A total of 67 samples from 9 different cosmetic industries were analysed. Arsenic was detected and determined quantitatively in 46 samples, ranging from 0.32 to 136 ppm. Mercury was not detected in any sample. The contamination of arsenic is due to the high concentration of this element in some of the raw material used in the manufacturing of the cosmetics, as was demonstrated by the analysis of these materials. (EC)

  9. IAEA instrumentation programme keeping pace with technology

    International Nuclear Information System (INIS)

    Fortakov, V.; Rundquist, D.E.

    1995-01-01

    Nuclear components, nuclear practices and nuclear facilities have all improved with the maturing of the industry. These improvements have been driven by forces, which are beyond the normal evolutionary pressures, such as increased safety, as low as possible radiation exposure for the workers as well as for the public and the increasing competiveness of alternative forms of energy generation. International nuclear safeguards has had to keep pace with these technological and administrative changes. Moreover, the political climate has changed since the initial implementation of safeguards under the Non-Proliferation Treaty. Implementation of safeguards agreements has accommodated to these changes as well as to the technical innovations. One important component of safeguards implementation, namely the instruments deployed by inspectors, has matured with the help of Member States. Continued efforts in the development and deployment of appropriate instruments are needed to maintain an acceptable level of efficiency and credibility. (orig.)

  10. KLF4 Nuclear Export Requires ERK Activation and Initiates Exit from Naive Pluripotency.

    Science.gov (United States)

    Dhaliwal, Navroop K; Miri, Kamelia; Davidson, Scott; Tamim El Jarkass, Hala; Mitchell, Jennifer A

    2018-04-10

    Cooperative action of a transcription factor complex containing OCT4, SOX2, NANOG, and KLF4 maintains the naive pluripotent state; however, less is known about the mechanisms that disrupt this complex, initiating exit from pluripotency. We show that, as embryonic stem cells (ESCs) exit pluripotency, KLF4 protein is exported from the nucleus causing rapid decline in Nanog and Klf4 transcription; as a result, KLF4 is the first pluripotency transcription factor removed from transcription-associated complexes during differentiation. KLF4 nuclear export requires ERK activation, and phosphorylation of KLF4 by ERK initiates interaction of KLF4 with nuclear export factor XPO1, leading to KLF4 export. Mutation of the ERK phosphorylation site in KLF4 (S132) blocks KLF4 nuclear export, the decline in Nanog, Klf4, and Sox2 mRNA, and differentiation. These findings demonstrate that relocalization of KLF4 to the cytoplasm is a critical first step in exit from the naive pluripotent state and initiation of ESC differentiation. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  11. An ultra-sensitive instrument for collision activated dissociation mass spectrometry with high mass resolution

    International Nuclear Information System (INIS)

    Louter, G.J.

    1982-01-01

    During the last decade Collision Activated Dissociation Mass Spectrometry (CAD-MS) has developed into an important and sometimes unique technique for the structure elucidation of ions. An extensive description of the double stage MS is given, which has been especially devloped for CAD-MS. A high mass resolution and a very high sensitivity are obtained by application of special techniques like post-acceleration of fragment ions, quadrupole (Q-pole) lenses and an electro-optical, simultaneous ion detection system. The operation of the rather complex ion-optics is demonstrated by application of a computer simulation of the tandem MS. Special attention is given to the action of the four Q-pole lenses and the second sector magnet upon curvature and position of the mass focal plane. Two mass calibration methods are described for the fragment spectra. The so-called polynomial-method applies a fifth-order polynomial approximation of the functional relation between position on the detector and corresponding relative momentum of fragment ions. The second method uses the matrix model of the instrument. The detector consists of two channelplates (CEMA), a fibre optics slab, coated with a phosphor layer, a camera objective and a 1024-channels photodiode-array. A bio-chemical and an organic-chemical application of the instrument are given. As bio-chemical application the peak m/z 59 in the pyrolysis mass spectrum of complete mycobacteria is identified. As an example of organic-chemical application the fragmentation process of 2,3-butadienoic acid has been investigated. (Auth.)

  12. Study of the trace element content in human cataractous lenses by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Kouris, T.; Theodossiadis, G.; Papadopoulou, C.; Kanias, G.D.; Baikraktari-Kouri, E.

    1986-01-01

    Cataract is a very common disease of the eye lens known since the ancient times. Different mechanisms are responsible for the biogenesis of cataract but the greater number of scientists agree with the theory that cataract formation can be attributed to metabolism disorders in the lens. Instrumental neutron activation analysis has been applied in this work for the determination of the following trace elements: antimony, cobalt, iron, rubidium, selenium and zinc in human lenses with mature cataract. The obtained results are statistically treated and correlated with age and sex of patients. Based on these findings the concentration of each studied element does not have any correlation with the age and/or sex of the patients i.e. when the lens becomes totally opaque. (author)

  13. Advanced In-Pile Instrumentation for Materials Testing Reactors

    Science.gov (United States)

    Rempe, J. L.; Knudson, D. L.; Daw, J. E.; Unruh, T. C.; Chase, B. M.; Davis, K. L.; Palmer, A. J.; Schley, R. S.

    2014-08-01

    The U.S. Department of Energy sponsors the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) program to promote U.S. research in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR NSUF facilitates basic and applied nuclear research and development, advancing U.S. energy security needs. A key component of the ATR NSUF effort is to design, develop, and deploy new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. This paper describes the strategy developed by the Idaho National Laboratory (INL) for identifying instrumentation needed for ATR irradiation tests and the program initiated to obtain these sensors. New sensors developed from this effort are identified, and the progress of other development efforts is summarized. As reported in this paper, INL researchers are currently involved in several tasks to deploy real-time length and flux detection sensors, and efforts have been initiated to develop a crack growth test rig. Tasks evaluating `advanced' technologies, such as fiber-optics based length detection and ultrasonic thermometers, are also underway. In addition, specialized sensors for real-time detection of temperature and thermal conductivity are not only being provided to NSUF reactors, but are also being provided to several international test reactors.

  14. FY09 Advanced Instrumentation and Active Interrogation Research for Safeguards

    International Nuclear Information System (INIS)

    Chichester, D.L.; Pozzi, S.A.; Seabury, E.H.; Dolan, J.L.; Flaska, M.; Johnson, J.T.; Watson, S.M.; Wharton, J.

    2009-01-01

    Multiple small-scale projects have been undertaken to investigate advanced instrumentation solutions for safeguard measurement challenges associated with advanced fuel cycle facilities and next-generation fuel reprocessing installations. These activities are in support of the U.S. Department of Energy's Fuel Cycle Research and Development program and its Materials Protection, Accounting, and Control for Transmutation (MPACT) campaign. (1) Work was performed in a collaboration with the University of Michigan (Prof. Sara Pozzi, co-PI) to investigate the use of liquid-scintillator radiation detectors for assaying mixed-oxide (MOX) fuel, to characterize its composition and to develop advanced digital pulse-shape discrimination algorithms for performing time-correlation measurements in the MOX fuel environment. This work included both simulations and experiments and has shown that these techniques may provide a valuable approach for use within advanced safeguard measurement scenarios. (2) Work was conducted in a collaboration with Oak Ridge National Laboratory (Dr. Paul Hausladen, co-PI) to evaluate the strengths and weaknesses of the fast-neutron coded-aperture imaging technique for locating and characterizing fissile material, and as a tool for performing hold-up measurements in fissile material handling facilities. This work involved experiments at Idaho National Laboratory, using MOX fuel and uranium metal, in both passive and active interrogation configurations. A complete analysis has not yet been completed but preliminary results suggest several potential uses for the fast neutron imaging technique. (3) Work was carried out to identify measurement approaches for determining nitric acid concentration in the range of 1-4 M and beyond. This work included laboratory measurements to investigate the suitability of prompt-gamma neutron activation analysis for this measurement and product reviews of other commercial solutions. Ultrasonic density analysis appears to be

  15. DEVELOPMENT OF AN ON-LINE, REAL-TIME ALPHA RADIATION MEASURING INSTRUMENT FOR LIQUID STREAMS

    International Nuclear Information System (INIS)

    Unknown

    1999-01-01

    Thermo Power Corporation has proven the technical viability of an on-line, real-time alpha radionuclide instrument for aqueous sample analysis through laboratory and initial field tests of the instrument. The instrument has been shown to be isotonically sensitive to extremely low (ten parts per trillion, or femto Curies per liter) levels of a broad range of radioisotopes. Performance enhancement and other scaling data obtained during the course of this investigation have shown that on-line, real-time operation is possible, with a sub 30-minute response time analyzing 20 ppb (30 pCi/1) natural uranium. Now that these initial field tests in Oak Ridge, Tennessee have been successfully completed, Thermo Power plans to conduct comprehensive field tests of the instrument. The purpose of these endurance tests will be to determine the endurance characteristics of the Thermo Alpha Monitor for Water when it is used by non-Thermo Power personnel in a series of one or more extended field tests. Such endurance testing is the vital next step towards the commercialization of the Alpha Monitor. Subsequently, it will be possible to provide the DOE with an instrument that has the capability of obtaining rapid feedback about the concentrations of alpha-emitting isotope contamination in effluent water streams (Subsurface Contaminants Focus Area). It will also be useful for process control of remediation and D and D operations such as monitoring scrubber/rinse water radioactivity levels (Mixed Waste, Plutonium and D and D Focus Areas)

  16. Standardization of portable assay instrumentation: the neutron-coincidence tree

    International Nuclear Information System (INIS)

    Menlove, H.O.

    1983-01-01

    Standardization of portable neutron assay instrumentation has been achieved by using the neutron coincidence technique as a common basis for a wide range of instruments and applications. The electronics originally developed for the High-Level Neutron Coincidence Counter has been adapted to both passive- and active-assay instrumentation for field verification of bulk plutonium, inventory samples, pellets, powders, nitrates, high-enriched uranium, and materials-testing-reactor, light-water-reactor, and mixed-oxide fuel assemblies. The family of detectors developed at Los Alamos National Laboratory and their performance under in-field conditions are described. 16 figures, 3 tables

  17. Absolute measurement of LDR brachytherapy source emitted power: Instrument design and initial measurements.

    Science.gov (United States)

    Malin, Martha J; Palmer, Benjamin R; DeWerd, Larry A

    2016-02-01

    Energy-based source strength metrics may find use with model-based dose calculation algorithms, but no instruments exist that can measure the energy emitted from low-dose rate (LDR) sources. This work developed a calorimetric technique for measuring the power emitted from encapsulated low-dose rate, photon-emitting brachytherapy sources. This quantity is called emitted power (EP). The measurement methodology, instrument design and performance, and EP measurements made with the calorimeter are presented in this work. A calorimeter operating with a liquid helium thermal sink was developed to measure EP from LDR brachytherapy sources. The calorimeter employed an electrical substitution technique to determine the power emitted from the source. The calorimeter's performance and thermal system were characterized. EP measurements were made using four (125)I sources with air-kerma strengths ranging from 2.3 to 5.6 U and corresponding EPs of 0.39-0.79 μW, respectively. Three Best Medical 2301 sources and one Oncura 6711 source were measured. EP was also computed by converting measured air-kerma strengths to EPs through Monte Carlo-derived conversion factors. The measured EP and derived EPs were compared to determine the accuracy of the calorimeter measurement technique. The calorimeter had a noise floor of 1-3 nW and a repeatability of 30-60 nW. The calorimeter was stable to within 5 nW over a 12 h measurement window. All measured values agreed with derived EPs to within 10%, with three of the four sources agreeing to within 4%. Calorimeter measurements had uncertainties ranging from 2.6% to 4.5% at the k = 1 level. The values of the derived EPs had uncertainties ranging from 2.9% to 3.6% at the k = 1 level. A calorimeter capable of measuring the EP from LDR sources has been developed and validated for (125)I sources with EPs between 0.43 and 0.79 μW.

  18. Objective physical activity measurement in the osteoarthritis initiative: Are guidelines being met?

    Science.gov (United States)

    Dunlop, Dorothy D; Song, Jing; Semanik, Pamela A; Chang, Rowland W; Sharma, Leena; Bathon, Joan M; Eaton, Charles B; Hochberg, Marc C; Jackson, Rebecca D; Kwoh, C Kent; Mysiw, W Jerry; Nevitt, Michael C; Hootman, Jennifer M

    2011-11-01

    Osteoarthritis (OA) clinical practice guidelines identify a substantial therapeutic role for physical activity, but objective information about the physical activity of this population is lacking. The aim of this study was to objectively measure levels of physical activity in adults with knee OA and report the prevalence of meeting public health physical activity guidelines. Cross-sectional accelerometry data from 1,111 adults with radiographic knee OA (49-84 years old) participating in the Osteoarthritis Initiative accelerometry monitoring ancillary study were assessed for meeting the aerobic component of the 2008 Physical Activity Guidelines for Americans (≥150 minutes/week moderate-to-vigorous-intensity activity lasting ≥10 minutes). Quantile regression was used to test median sex differences in physical activity levels. Aerobic physical activity guidelines were met by 12.9% of men and 7.7% of women with knee OA. A substantial proportion of men and women (40.1% and 56.5%, respectively) were inactive, having done no moderate-to-vigorous activity that lasted 10 minutes or more during the 7 days. Although men engaged in significantly more moderate-to-vigorous activity (average daily minutes 20.7 versus 12.3), they also spent more time in no or very-low-intensity activity than women (average daily minutes 608.2 versus 585.8). Despite substantial health benefits from physical activity, adults with knee OA were particularly inactive based on objective accelerometry monitoring. The proportions of men and women who met public health physical activity guidelines were substantially less than those previously reported based on self-reported activity in arthritis populations. These findings support intensified public health efforts to increase physical activity levels among people with knee OA. Copyright © 2011 by the American College of Rheumatology.

  19. The compatibility of flexible instruments under the Kyoto Protocol

    International Nuclear Information System (INIS)

    Jepma, C.J.; Van der Gaast, W.P.; Woerdman, E.

    1998-01-01

    The compatibility of the Kyoto Protocol flexible instruments and the lessons that can be learned form the AIJ-phase (AIJ stands for Activities Implemented Jointly) are discussed. The key point to be made is that there may be various applications of flexible instruments which can create situations where the various instruments would crowd out each other. On the other hand, applying flexible instruments may create a leverage for Parties in terms of achieving domestic environmental objectives. In addition, several issues related to the implementation of Joint Implementation (JI) , Clean Development Mechanism (CDM) and international emissions trading are discussed. The issues concern mainly those that have been included in the working programme on flexible instruments for CoP4 and CoP5 (CoP stands for Convention of Parties). As such the report discusses the consequences of possible negotiations outcomes at CoP for the effectiveness of flexible instruments, Parties' capabilities to achieve their Kyoto Protocol commitments cost-effectively, and the role of the private sector on the national and international credits markets(s). 106 refs

  20. Information barriers in the trilateral initiative: Conceptual description

    International Nuclear Information System (INIS)

    Whiteson, R.; MacArthur, D.W.

    1998-01-01

    In this paper the authors attempt to define the structure and requirements (both in hardware and software) of an information barrier (IB) for the trilateral initiative. This IB concept will be employed in the radiation measurement instrument(s) used for attribute verification of excess fissile materials offered for international safeguarding. In this paper, they will specifically not attempt to present a list of solutions to the problems, but instead, concentrate on generating a thorough discussion of the goals and problems themselves. In some cases they have presented potential solutions; these discussions are meant as illustrations of the types of systems required and are not intended as endorsements of any particular solution