WorldWideScience

Sample records for instrument stray light

  1. Stray light analysis and control

    CERN Document Server

    Fest, Eric

    2013-01-01

    Stray light is defined as unwanted light in an optical system, a familiar concept for anyone who has taken a photograph with the sun in or near their camera's field of view. This book addresses stray light terminology, radiometry, and the physics of stray light mechanisms, such as surface roughness scatter and ghost reflections. The most-efficient ways of using stray light analysis software packages are included. The book also demonstrates how the basic principles are applied in the design, fabrication, and testing phases of optical system development.

  2. Carbon Nanotubes on Titanium Substrates for Stray Light Suppression

    Science.gov (United States)

    Hagopian, John; Getty, Stephanie; Quijada, Manuel

    2011-01-01

    A method has been developed for growing carbon nanotubes on a titanium substrate, which makes the nano tubes ten times blacker than the current state-of-the-art paints in the visible to near infrared. This will allow for significant improvement of stray light performance in scientific instruments, or any other optical system. Because baffles, stops, and tubes used in scientific observations often undergo loads such as vibration, it is critical to develop this surface treatment on structural materials. This innovation optimizes the carbon nano - tube growth for titanium, which is a strong, lightweight structural material suitable for spaceflight use. The steps required to grow the nanotubes require the preparation of the surface by lapping, and the deposition of an iron catalyst over an alumina stiction layer by e-beam evaporation. In operation, the stray light controls are fabricated, and nanotubes (multi-walled 100 microns in length) are grown on the surface. They are then installed in the instruments or other optical devices.

  3. Pitfalls and artifacts in measuring absorption spectra and kinetics: the effect of stray light in the UV and red regions

    International Nuclear Information System (INIS)

    Czapski, Gideon; Ozeri, Yair; Goldstein, Sara

    2005-01-01

    Effects of stray light on absorption spectrum and kinetics are discussed. The extent of the stray light depends on the light source, monochromator, wavelength set by the instrument and the absorption of the sample at this wavelength. Effects of the stray light on the shape of the spectrum and the extinction coefficients are shown. Methods for determining the existence and extent of stray light are suggested and are especially relevant for studies using pulse radiolysis, flash photolysis, and stopped-flow techniques. The literature examples for artifacts due to stray light are presented for kinetics and absorption spectra

  4. Stray light characteristics of the diffractive telescope system

    Science.gov (United States)

    Liu, Dun; Wang, Lihua; Yang, Wei; Wu, Shibin; Fan, Bin; Wu, Fan

    2018-02-01

    Diffractive telescope technology is an innovation solution in construction of large light-weight space telescope. However, the nondesign orders of diffractive optical elements (DOEs) may affect the imaging performance as stray light. To study the stray light characteristics of a diffractive telescope, a prototype was developed and its stray light analysis model was established. The stray light characteristics including ghost, point source transmittance, and veiling glare index (VGI) were analyzed. During the star imaging test of the prototype, the ghost images appeared around the star image as the exposure time of the charge-coupled device improving, consistent with the simulation results. The test result of VGI was 67.11%, slightly higher than the calculated value 57.88%. The study shows that the same order diffraction of the diffractive primary lens and correcting DOE is the main factor that causes ghost images. The stray light sources outside the field of view can illuminate the image plane through nondesign orders diffraction of the primary lens and contributes to more than 90% of the stray light flux on the image plane. In summary, it is expected that these works will provide some guidance for optimizing the imaging performance of diffractive telescopes.

  5. Stray light reduction for Thomson scattering

    NARCIS (Netherlands)

    Bakker, L.P.; Kroesen, G.M.W.; Doebele, H.F.; Muraoka, K.

    1999-01-01

    In order to perform Thomson scattering in a gas discharge tube, the reduction of stray light is very important because of the very small Thomson cross-section. By introducing a sodium absorption cell as a notch filter, we can reduce the measured stray light considerably. Then we have to use a dye

  6. Influence of stray light for divertor spectroscopy in ITER

    International Nuclear Information System (INIS)

    Kajita, Shin; Veshchev, Evgeny; Lisgo, Steve; Barnsley, Robin; Morgan, Philip; Walsh, Michael; Ogawa, Hiroaki; Sugie, Tatsuo; Itami, Kiyoshi

    2015-01-01

    The influence of stray light in the divertor spectroscopy system in ITER is quantitatively investigated using a ray tracing simulation. Simulation results show that the stray light is negligible at positions in the divertor where the plasma emission is strong. However, it is also shown that the stray light can be significantly greater than the real signal if the plasma intensity is low. Deuterium and beryllium emissions are used for the assessment; for beryllium cases in particular, since the emission profile may be non-uniform in the divertor region, the influence of stray light can be non-negligible at some positions, e.g., above the divertor dome

  7. Stray light suppression in the Goddard IRAM 2-Millimeter Observer (GISMO)

    Science.gov (United States)

    Sharp, E. H.; Benford, D. J.; Fixsen, D. J.; Moseley, S. H.; Staguhn, J. G.; Wollack, E. J.

    2012-09-01

    The Goddard-IRAM Superconducting 2 Millimeter Observer (GISMO) is an 8x16 Transition Edge Sensor (TES) array of bolometers built as a pathfinder for TES detector development efforts at NASA Goddard Space Flight Center. GISMO has been used annually at the Institut de Radioastronomie Millimétrique (IRAM) 30 meter telescope since 2007 under engineering time and was opened in the spring of 2012 to the general astronomical community. The spring deployment provided an opportunity to modify elements of the room temperature optics before moving the instrument to its new permanent position in the telescope receiver cabin. This allowed for the possibility to extend the cryostat, introduce improved cold baffling and thus further optimize the stray light performance for final astronomical use of the instrument, which has been completed and validated. We will demonstrate and discuss several of the methods used to quantify and limit the influence of stray light in the GISMO camera.

  8. ON THE INVERSION OF STOKES PROFILES WITH LOCAL STRAY-LIGHT CONTAMINATION

    International Nuclear Information System (INIS)

    Asensio Ramos, A.; Manso Sainz, R.

    2011-01-01

    Obtaining the magnetic properties of non-resolved structures in the solar photosphere is always challenging and problems arise because the inversion is carried out through the numerical minimization of a merit function that depends on the proposed model. We investigate the reliability of inversions in which the stray-light contamination is obtained from the same observations as a local average. In this case, we show that it is fundamental to include the covariance between the observed Stokes profiles and the stray-light contamination. The ensuing modified merit function of the inversion process penalizes large stray-light contaminations simply because of the presence of positive correlations between the observables and the stray light, fundamentally produced by spatially variable systematics. We caution that if the wrong merit function is used, artificially large stray-light contaminations might be inferred. Since this effect disappears if the stray-light contamination is obtained as an average over the full field of view, we recommend taking into account stray-light contamination using a global approach.

  9. Stray light field dependence for large astronomical space telescopes

    Science.gov (United States)

    Lightsey, Paul A.; Bowers, Charles W.

    2017-09-01

    Future large astronomical telescopes in space will have architectures that expose the optics to large angular extents of the sky. Options for reducing stray light coming from the sky range from enclosing the telescope in a tubular baffle to having an open telescope structure with a large sunshield to eliminate solar illumination. These two options are considered for an on-axis telescope design to explore stray light considerations. A tubular baffle design will limit the sky exposure to the solid angle of the cone in front of the telescope set by the aspect ratio of the baffle length to Primary Mirror (PM) diameter. Illumination from this portion of the sky will be limited to the PM and structures internal to the tubular baffle. Alternatively, an open structure design will allow a large portion of the sky to directly illuminate the PM and Secondary Mirror (SM) as well as illuminating sunshield and other structure surfaces which will reflect or scatter light onto the PM and SM. Portions of this illumination of the PM and SM will be scattered into the optical train as stray light. A Radiance Transfer Function (RTF) is calculated for the open architecture that determines the ratio of the stray light background radiance in the image contributed by a patch of sky having unit radiance. The full 4π steradian of sky is divided into a grid of patches, with the location of each patch defined in the telescope coordinate system. By rotating the celestial sky radiance maps into the telescope coordinate frame for a given pointing direction of the telescope, the RTF may be applied to the sky brightness and the results integrated to get the total stray light from the sky for that pointing direction. The RTF data generated for the open architecture may analyzed as a function of the expanding cone angle about the pointing direction. In this manner, the open architecture data may be used to directly compare to a tubular baffle design parameterized by allowed cone angle based on the

  10. Fast and accurate modeling of stray light in optical systems

    Science.gov (United States)

    Perrin, Jean-Claude

    2017-11-01

    The first problem to be solved in most optical designs with respect to stray light is that of internal reflections on the several surfaces of individual lenses and mirrors, and on the detector itself. The level of stray light ratio can be considerably reduced by taking into account the stray light during the optimization to determine solutions in which the irradiance due to these ghosts is kept to the minimum possible value. Unhappily, the routines available in most optical design software's, for example CODE V, do not permit all alone to make exact quantitative calculations of the stray light due to these ghosts. Therefore, the engineer in charge of the optical design is confronted to the problem of using two different software's, one for the design and optimization, for example CODE V, one for stray light analysis, for example ASAP. This makes a complete optimization very complex . Nevertheless, using special techniques and combinations of the routines available in CODE V, it is possible to have at its disposal a software macro tool to do such an analysis quickly and accurately, including Monte-Carlo ray tracing, or taking into account diffraction effects. This analysis can be done in a few minutes, to be compared to hours with other software's.

  11. Usage of ray tracing transfer matrix to mitigate the stray light for ITER spectroscopy

    International Nuclear Information System (INIS)

    Kajita, S.; Veshchev, E.; Barnsley, R.; Walsh, M.

    2016-01-01

    Stray light formed by the reflection of photons on inner wall from a bright divertor region can be a serious issue in spectroscopic measurement systems in ITER. In this study, we propose a method to mitigate the influence of stray light using a ray tracing analysis. Usually, a ray tracing simulation requires a time consuming runs. We constructed transfer matrices based on the ray tracing simulation results and used them to demonstrate the influence of stray light. It is shown that the transfer matrix can be used to reconstruct the emission profile by considering the influence of the stray light without any additional ray tracing runs. Mitigation of the stray light in ITER divertor impurity monitor was demonstrated, and a method of prediction of the stray light level for the scrape off layer spectroscopy from divertor region was proposed. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  12. Identification and mitigation of stray laser light in the Thomson scattering system on the Madison Symmetric Torus (MST)

    Energy Technology Data Exchange (ETDEWEB)

    Jacobson, C. M., E-mail: cjacobson@wisc.edu; Borchardt, M. T.; Den Hartog, D. J.; Falkowski, A. F.; Morton, L. A.; Thomas, M. A. [Department of Physics, University of Wisconsin–Madison, 1150 University Avenue, Madison, Wisconsin 53706 (United States)

    2016-11-15

    The Thomson scattering diagnostic on the Madison Symmetric Torus (MST) records excessive levels of stray Nd:YAG laser light. Stray light saturates the 1064 nm spectral channel in all polychromators, which prevents absolute electron density measurements via Rayleigh scattering calibration. Furthermore, stray light contaminates adjacent spectral channels for r/a ≥ 0.75, which renders the diagnostic unable to make electron temperature measurements at these radii. In situ measurements of stray light levels during a vacuum vessel vent are used to identify stray light sources and strategies for reduction of stray light levels. Numerical modeling using Zemax OpticStudio supports these measurements. The model of the vacuum vessel and diagnostic includes synthetic collection optics to enable direct comparison of measured and simulated stray light levels. Modeling produces qualitatively similar stray light distributions to MST measurements, and quantifies the mitigation effects of stray light mitigation strategies prior to implementation.

  13. Identification and mitigation of stray laser light in the Thomson scattering system on the Madison Symmetric Torus (MST)

    International Nuclear Information System (INIS)

    Jacobson, C. M.; Borchardt, M. T.; Den Hartog, D. J.; Falkowski, A. F.; Morton, L. A.; Thomas, M. A.

    2016-01-01

    The Thomson scattering diagnostic on the Madison Symmetric Torus (MST) records excessive levels of stray Nd:YAG laser light. Stray light saturates the 1064 nm spectral channel in all polychromators, which prevents absolute electron density measurements via Rayleigh scattering calibration. Furthermore, stray light contaminates adjacent spectral channels for r/a ≥ 0.75, which renders the diagnostic unable to make electron temperature measurements at these radii. In situ measurements of stray light levels during a vacuum vessel vent are used to identify stray light sources and strategies for reduction of stray light levels. Numerical modeling using Zemax OpticStudio supports these measurements. The model of the vacuum vessel and diagnostic includes synthetic collection optics to enable direct comparison of measured and simulated stray light levels. Modeling produces qualitatively similar stray light distributions to MST measurements, and quantifies the mitigation effects of stray light mitigation strategies prior to implementation.

  14. [Influence of different multifocal intraocular lens concepts on retinal stray light parameters].

    Science.gov (United States)

    Ehmer, A; Rabsilber, T M; Mannsfeld, A; Sanchez, M J; Holzer, M P; Auffarth, G U

    2011-10-01

    Multifocal intraocular lenses (MIOL) are known to induce various photic phenomena depending on the optical principle. The aim of this study was to investigate the correlation between stray light measurements performed with the C-Quant (Oculus, Germany) and the results of a subjective patient questionnaire. In this study three different MIOLs were compared: AMO ReZoom (refractive design, n=10), AMO ZM900 (diffractive design, n=10) and Oculentis Mplus (near segment design, n=10). Cataract and refractive patients were enrolled in the study. Functional results were evaluated at least 3 months postoperatively followed by stray light measurements and a subjective questionnaire. Surgery was performed for all patients without complications. The three groups were matched for age, IOL power and corrected distance visual acuity (CDVA). Significantly different stray light (median) values log(s) were found (Kruskal-Wallis test, p<0.05): 1.12 log (refractive), 1.13 log (segment) and 1.28 log (diffractive). The subjective questionnaire did not show differences in glare perception but refractive MIOL patients noticed more halos surrounding light sources than the diffractive and segment MIOL patients. Stray light and subjective photopic phenomena do not show any basic correlation. Measurements in patients with refractive MIOLs showed less stray light than near segment or diffractive MIOLs. However, refractive MIOLs induced more halos compared to the other groups analyzed.

  15. An assessment of the stray light in 25 years of Dobson total ozone data at Athens, Greece

    Science.gov (United States)

    Christodoulakis, J.; Varotsos, C.; Cracknell, A. P.; Tzanis, C.; Neofytos, A.

    2015-07-01

    In this study, we investigated the susceptibility of the Dobson spectrophotometer No. 118 to stray light interference. In this regard, a series of total ozone content measurements were carried out in Athens, Greece for air-mass values (μ) extending up to μ = 5. The monochromatic-heterochromatic stray light derived by Basher's model was used in order to evaluate the specific instrumental parameters which determine if this instrument suffers from this problem or not. The results obtained indicate that the measurements made by the Dobson instrument of the Athens station for air mass values up to 2.5, underestimates the total ozone content by 3.5 DU in average, or about 1 % of the station's mean total ozone content (TOC). The comparison of the values of the same parameters measured 15 years ago with the present ones indicates the good maintenance of the Dobson spectrophotometer No. 118. This fact is of crucial importance because the variability of the daily total ozone observations collected by the Athens Dobson Station since 1989 has proved to be representative to the variability of the mean total ozone observed over the whole mid-latitude zone of the Northern Hemisphere. This stresses the point that the Athens total ozone station, being the unique Dobson station in south-eastern Europe, may be assumed as a ground truth station for the reliable conversion of the satellite radiance observations to total ozone measurements.

  16. Comparison of stray light in spectrometer systems using a low cost monochromatic light source

    DEFF Research Database (Denmark)

    Thorseth, Anders; Lindén, Johannes; Dam-Hansen, Carsten

    2014-01-01

    We present an experimental setup that is under development for automated stray light characterization of spectrometers. The setup uses a tuneable monochromator which enables this characterization on relatively cost low equipment. We present the measured line spread functions for two spectrometers...

  17. Stray light correction on array spectroradiometers for optical radiation risk assessment in the workplace

    International Nuclear Information System (INIS)

    Barlier-Salsi, A

    2014-01-01

    The European directive 2006/25/EC requires the employer to assess and, if necessary, measure the levels of exposure to optical radiation in the workplace. Array spectroradiometers can measure optical radiation from various types of sources; however poor stray light rejection affects their accuracy. A stray light correction matrix, using a tunable laser, was developed at the National Institute of Standards and Technology (NIST). As tunable lasers are very expensive, the purpose of this study was to implement this method using only nine low power lasers; other elements of the correction matrix being completed by interpolation and extrapolation. The correction efficiency was evaluated by comparing CCD spectroradiometers with and without correction and a scanning double monochromator device as reference. Similar to findings recorded by NIST, these experiments show that it is possible to reduce the spectral stray light by one or two orders of magnitude. In terms of workplace risk assessment, this spectral stray light correction method helps determine exposure levels, with an acceptable degree of uncertainty, for the majority of workplace situations. The level of uncertainty depends upon the model of spectroradiometers used; the best results are obtained with CCD detectors having an enhanced spectral sensitivity in the UV range. Thus corrected spectroradiometers require a validation against a scanning double monochromator spectroradiometer before using them for risk assessment in the workplace. (paper)

  18. Stray light correction on array spectroradiometers for optical radiation risk assessment in the workplace.

    Science.gov (United States)

    Barlier-Salsi, A

    2014-12-01

    The European directive 2006/25/EC requires the employer to assess and, if necessary, measure the levels of exposure to optical radiation in the workplace. Array spectroradiometers can measure optical radiation from various types of sources; however poor stray light rejection affects their accuracy. A stray light correction matrix, using a tunable laser, was developed at the National Institute of Standards and Technology (NIST). As tunable lasers are very expensive, the purpose of this study was to implement this method using only nine low power lasers; other elements of the correction matrix being completed by interpolation and extrapolation. The correction efficiency was evaluated by comparing CCD spectroradiometers with and without correction and a scanning double monochromator device as reference. Similar to findings recorded by NIST, these experiments show that it is possible to reduce the spectral stray light by one or two orders of magnitude. In terms of workplace risk assessment, this spectral stray light correction method helps determine exposure levels, with an acceptable degree of uncertainty, for the majority of workplace situations. The level of uncertainty depends upon the model of spectroradiometers used; the best results are obtained with CCD detectors having an enhanced spectral sensitivity in the UV range. Thus corrected spectroradiometers require a validation against a scanning double monochromator spectroradiometer before using them for risk assessment in the workplace.

  19. Low-Energy Microfocus X-Ray Source for Enhanced Testing Capability in the Stray Light Facility

    Science.gov (United States)

    Gaskin, Jessica; O'Dell, Stephen; Kolodziejczak, Jeff

    2015-01-01

    Research toward high-resolution, soft x-ray optics (mirrors and gratings) necessary for the next generation large x-ray observatories requires x-ray testing using a low-energy x-ray source with fine angular size (energy microfocus (approximately 0.1 mm spot) x-ray source from TruFocus Corporation that mates directly to the Stray Light Facility (SLF). MSFC X-ray Astronomy team members are internationally recognized for their expertise in the development, fabrication, and testing of grazing-incidence optics for x-ray telescopes. One of the key MSFC facilities for testing novel x-ray instrumentation is the SLF. This facility is an approximately 100-m-long beam line equipped with multiple x-ray sources and detectors. This new source adds to the already robust compliment of instrumentation, allowing MSFC to support additional internal and community x-ray testing needs.

  20. The Design, Construction and Test of stray light suppression baffles for the CHAMP satellite

    DEFF Research Database (Denmark)

    Jørgensen, John Leif

    1997-01-01

    The Advanced Stellar Compass, to be delivered from IAU to the CHAMP project, requires some kind of stray-light suppressing shade to be mounted in front of the lens, in order to minimize the thermal impact and to maximize the performance envelope when subjected to non-stellar external light sources...

  1. Effects of different levels of intraocular stray light on kinetic perimetry findings.

    Directory of Open Access Journals (Sweden)

    Kazunori Hirasawa

    Full Text Available To evaluate the effect of different levels of intraocular stray light on kinetic perimetry findings.Twenty-five eyes of 25 healthy young participants were examined by automated kinetic perimetry (Octopus 900 using Goldmann stimuli III4e, I4e, I3e, I2e, and I1e. Each stimulus was presented with a velocity of 3°/s at 24 meridians with 15° intervals. Four levels of intraocular stray light were induced using non-white opacity filter (WOF filters and WOFs applied to the clear plastic eye covers of the participants. The visual acuity, pupil diameter, isopter area, and kinetic sensitivity of each meridian were analyzed for each WOF density.Visual acuity deteriorated with increasing WOF densities (p < 0.01. With a visual acuity of 0.1 LogMAR units, the isopter areas for III4e, I4e, I3e, I2e, and I1e decreased by -32.7 degree2 (-0.2%, -255.7 degree2 (-2.6%, -381.2 degree2 (-6.2%, -314.8 degree2 (-12.8%, and -59.2 degree2 (-15.2%, respectively; kinetic sensitivity for those stimuli decreased by -0.1 degree (-0.1%, -0.8 degree (-1.4%, -1.6 degree (-3.7%, -2.7 degree (-9.7%, and -1.7 degree (-16.2%, respectively. The pupil diameter with each WOF density was not significantly different.Kinetic perimetry measurements with a high-intensity stimulus (i.e., III4e were unaffected by intraocular stray light. In contrast, measurements with the I4e, I3e, I2e, and I1e stimuli, especially I2e and I1e, were affected. Changes in the shape of the isopter resulting from opacity must be monitored, especially in cases of smaller and lower-intensity stimuli.

  2. Bidirectional reflectance distribution function /BRDF/ measurements of stray light suppression coatings for the Space Telescope /ST/

    Science.gov (United States)

    Griner, D. B.

    1979-01-01

    The paper considers the bidirectional reflectance distribution function (BRDF) of black coatings used on stray light suppression systems for the Space Telescope (ST). The ST stray light suppression requirement is to reduce earth, moon, and sun light in the focal plane to a level equivalent to one 23 Mv star per square arcsecond, an attenuation of 14 orders of magnitude. It is impractical to verify the performance of a proposed baffle system design by full scale tests because of the large size of the ST, so that a computer analysis is used to select the design. Accurate computer analysis requires a knowledge of the diffuse scatter at all angles from the surface of the coatings, for all angles of incident light. During the early phases of the ST program a BRDF scanner was built at the Marshall Space Flight Center to study the scatter from black materials; the measurement system is described and the results of measurements on samples proposed for use on the ST are presented.

  3. Fast space-varying convolution using matrix source coding with applications to camera stray light reduction.

    Science.gov (United States)

    Wei, Jianing; Bouman, Charles A; Allebach, Jan P

    2014-05-01

    Many imaging applications require the implementation of space-varying convolution for accurate restoration and reconstruction of images. Here, we use the term space-varying convolution to refer to linear operators whose impulse response has slow spatial variation. In addition, these space-varying convolution operators are often dense, so direct implementation of the convolution operator is typically computationally impractical. One such example is the problem of stray light reduction in digital cameras, which requires the implementation of a dense space-varying deconvolution operator. However, other inverse problems, such as iterative tomographic reconstruction, can also depend on the implementation of dense space-varying convolution. While space-invariant convolution can be efficiently implemented with the fast Fourier transform, this approach does not work for space-varying operators. So direct convolution is often the only option for implementing space-varying convolution. In this paper, we develop a general approach to the efficient implementation of space-varying convolution, and demonstrate its use in the application of stray light reduction. Our approach, which we call matrix source coding, is based on lossy source coding of the dense space-varying convolution matrix. Importantly, by coding the transformation matrix, we not only reduce the memory required to store it; we also dramatically reduce the computation required to implement matrix-vector products. Our algorithm is able to reduce computation by approximately factoring the dense space-varying convolution operator into a product of sparse transforms. Experimental results show that our method can dramatically reduce the computation required for stray light reduction while maintaining high accuracy.

  4. Effects of stray lights on Faraday rotation measurement for polarimeter-interferometer system on EAST.

    Science.gov (United States)

    Zou, Z Y; Liu, H Q; Ding, W X; Chen, J; Brower, D L; Lian, H; Wang, S X; Li, W M; Yao, Y; Zeng, L; Jie, Y X

    2018-01-01

    A double-pass radially view 11 chords polarimeter-interferometer system has been operated on the experimental advanced superconducting tokamak and provides important current profile information for plasma control. Stray light originating from spurious reflections along the optical path (unwanted reflections from various optical components/mounts and transmissive optical elements such as windows, waveplates, and lens as well as the detectors) and also direct feedback from the retro-reflector used to realize the double-pass configuration can both contribute to contamination of the Faraday rotation measurement accuracy. Modulation of the Faraday rotation signal due to the interference from multiple reflections is observable when the interferometer phase (plasma density) varies with time. Direct reflection from the detector itself can be suppressed by employing an optical isolator consisting of a λ/4-waveplate and polarizer positioned in front of the mixer. A Faraday angle oscillation during the density ramping up (or down) can be reduced from 5°-10° to 1°-2° by eliminating reflections from the detector. Residual modulation arising from misalignment and stray light from other sources must be minimized to achieve accurate measurements of Faraday rotation.

  5. Global auroral imaging instrumentation for the dynamics explorer mission

    International Nuclear Information System (INIS)

    Frank, L.A.; Craven, J.D.; Ackerson, K.L.; English, M.R.; Eather, R.H.; Carovillano, R.L.

    1981-01-01

    The instrumentation for gaining global images of the auroral oval from the high-altitude spacecraft of the Dynamics Explorer Mission is described. Three spin-scan auroral imaging (SAI) photometers are expected to be able to effectively view the dim emissions from earth in the presence of strong stray light sources near their fields-of-view along the sunlit portion of the spacecraft orbit. A special optical design which includes an off-axis parabolic mirror as the focusing element and super-reflecting mirror surfaces is used to minimize the effects of stray light. The rotation of the spacecraft and an instrument scanning mirror provide the two-dimensional array of pixels comprising an image frame. (orig.)

  6. A high-power spatial filter for Thomson scattering stray light reduction

    Science.gov (United States)

    Levesque, J. P.; Litzner, K. D.; Mauel, M. E.; Maurer, D. A.; Navratil, G. A.; Pedersen, T. S.

    2011-03-01

    The Thomson scattering diagnostic on the High Beta Tokamak-Extended Pulse (HBT-EP) is routinely used to measure electron temperature and density during plasma discharges. Avalanche photodiodes in a five-channel interference filter polychromator measure scattered light from a 6 ns, 800 mJ, 1064 nm Nd:YAG laser pulse. A low cost, high-power spatial filter was designed, tested, and added to the laser beamline in order to reduce stray laser light to levels which are acceptable for accurate Rayleigh calibration. A detailed analysis of the spatial filter design and performance is given. The spatial filter can be easily implemented in an existing Thomson scattering system without the need to disturb the vacuum chamber or significantly change the beamline. Although apertures in the spatial filter suffer substantial damage from the focused beam, with proper design they can last long enough to permit absolute calibration.

  7. STRAY - An interactive program for the computation of stray radiation in infrared telescopes

    Science.gov (United States)

    St. Clair Dinger, Ann

    1987-01-01

    The STRAY program to model the amount of stray radiation reaching the focal plane of a well-baffled telescope is described. The STRAY telescope model is addressed, including the aperture shade, barrel baffle, optics, mirror sectioning and chopping, and off-axis points in focal plane. The possible illumination paths are shown, and calculation options using STRAY are discussed. The stored data and computational aspects of STRAY are addressed. STRAY is compared to the MINI-APART model, and applications of STRAY are described.

  8. Stray radiation and the Infrared Astronomical Satellite /IRAS/ telescope

    Science.gov (United States)

    Noll, R. J.; Harned, R.; Breault, R. P.; Malugin, R.

    1981-01-01

    Stray light control is a major consideration in the design of infrared cryogenically cooled telescopes such as the Infrared Astronomical Satellite (IRAS). The basic design of the baffle system, and the placement, shape, and coating of the secondary support struts for the telescope subsystem are described. The intent of this paper is to highlight the stray light problems encountered while designing the system, and to illustrate how computer analysis can be a useful design aid. Scattering measurements of the primary mirror, and a full system level scatter measurement are presented. Comparisons of predicted performance with the measured results are also presented.

  9. Stray voltage mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Jamali, B.; Piercy, R.; Dick, P. [Kinetrics Inc., Toronto, ON (Canada). Transmission and Distribution Technologies

    2008-04-09

    This report discussed issues related to farm stray voltage and evaluated mitigation strategies and costs for limiting voltage to farms. A 3-phase, 3-wire system with no neutral ground was used throughout North America before the 1930s. Transformers were connected phase to phase without any electrical connection between the primary and secondary sides of the transformers. Distribution voltage levels were then increased and multi-grounded neutral wires were added. The earth now forms a parallel return path for the neutral current that allows part of the neutral current to flow continuously through the earth. The arrangement is responsible for causing stray voltage. Stray voltage causes uneven milk production, increased incidences of mastitis, and can create a reluctance to drink water amongst cows when stray voltages are present. Off-farm sources of stray voltage include phase unbalances, undersized neutral wire, and high resistance splices on the neutral wire. Mitigation strategies for reducing stray voltage include phase balancing; conversion from single to 3-phase; increasing distribution voltage levels, and changing pole configurations. 22 refs., 5 tabs., 13 figs.

  10. Comparison of the performance of different instruments in the stray neutron field around the CERN Proton Synchrotron.

    Science.gov (United States)

    Aza, Eleni; Caresana, Marco; Cassell, Christopher; Colombo, Valeria; Damjanovic, Sanja; Gilardoni, Simone; Manessi, Giacomo Paolo; Pangallo, Michel; Perrin, Daniel; Silari, Marco

    2014-10-01

    This paper discusses an intercomparison campaign carried out in several locations around the CERN Proton Synchrotron. The locations were selected in order to perform the measurements in different stray field conditions. Various neutron detectors were employed: ionisation chambers, conventional and extended range rem counters, both commercial and prototype ones, including a novel instrument called LUPIN, specifically conceived to work in pulsed fields. The attention was focused on the potential differences in the instrument readings due to dead-time losses that are expected to affect most commercial units. The results show that the ionisation chambers and LUPIN agree well with the expected H*(10) values, as derived from FLUKA simulations, showing no relevant underestimations even in strongly pulsed fields. On the contrary, the dead-time losses of the other rem counters induced an underestimation in pulsed fields that was more important for instruments characterised by a higher dead time. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Towards the retrieval of tropospheric ozone with the ozone monitoring instrument (OMI)

    NARCIS (Netherlands)

    Mielonen, T.; De Haan, J.F.; Van Peet, J.C.A.; Eremenko, M.; Veefkind, J.P.

    2015-01-01

    We have assessed the sensitivity of the operational Ozone Monitoring Instrument (OMI) ozone profile retrieval algorithm to a number of a priori and radiative transfer assumptions. We studied the effect of stray light correction, surface albedo assumptions and a priori ozone profiles on the retrieved

  12. White light coronagraph in OSO-7

    International Nuclear Information System (INIS)

    Koomen, M.J.; Detwiler, C.R.; Brueckner, G.E.; Cooper, H.W.; Tousey, R.

    1975-01-01

    A small, externally occulted Lyot-type coronagraph, designated for use in the seventh unmanned Orbiting Solar Observatory (OSO-7), is described. Optical configuration, suppression of stray light, SEC vidicon detector, and data system are discussed, as well as integration of the instrument into the spacecraft and operation in orbit. Orbital operation produced daily images of the white light corona, from 2.8 to 10 solar radii, at least once per day for 2 3/4 yr. The first records of white light coronal transient events were obtained, and the corona was shown to be constantly changing

  13. Advanced optical instruments technology

    Science.gov (United States)

    Shao, Mike; Chrisp, Michael; Cheng, Li-Jen; Eng, Sverre; Glavich, Thomas; Goad, Larry; Jones, Bill; Kaarat, Philip; Nein, Max; Robinson, William

    1992-08-01

    The science objectives for proposed NASA missions for the next decades push the state of the art in sensitivity and spatial resolution over a wide range of wavelengths, including the x-ray to the submillimeter. While some of the proposed missions are larger and more sensitive versions of familiar concepts, such as the next generation space telescope, others use concepts, common on the Earth, but new to space, such as optical interferometry, in order to provide spatial resolutions impossible with other concepts. However, despite their architecture, the performance of all of the proposed missions depends critically on the back-end instruments that process the collected energy to produce scientifically interesting outputs. The Advanced Optical Instruments Technology panel was chartered with defining technology development plans that would best improve optical instrument performance for future astrophysics missions. At this workshop the optical instrument was defined as the set of optical components that reimage the light from the telescope onto the detectors to provide information about the spatial, spectral, and polarization properties of the light. This definition was used to distinguish the optical instrument technology issues from those associated with the telescope, which were covered by a separate panel. The panel identified several areas for optical component technology development: diffraction gratings; tunable filters; interferometric beam combiners; optical materials; and fiber optics. The panel also determined that stray light suppression instruments, such as coronagraphs and nulling interferometers, were in need of general development to support future astrophysics needs.

  14. Rf Discharge Impedance Measurements Using a New Method to Determine the Stray Impedances

    NARCIS (Netherlands)

    Bakker, L.P.; Kroesen, G.M.W.; Hoog, de F.J.

    1999-01-01

    The impedance of a capacitively coupled radio frequency discharge in a tubular fluorescent lamp filled with neon and mercury is measured. The stray impedances in the electrical network are determined using a new method that requires no extra instruments. The reflection of power is used to determine

  15. Laser light scattering instrument advanced technology development

    Science.gov (United States)

    Wallace, J. F.

    1993-01-01

    The objective of this advanced technology development (ATD) project has been to provide sturdy, miniaturized laser light scattering (LLS) instrumentation for use in microgravity experiments. To do this, we assessed user requirements, explored the capabilities of existing and prospective laser light scattering hardware, and both coordinated and participated in the hardware and software advances needed for a flight hardware instrument. We have successfully breadboarded and evaluated an engineering version of a single-angle glove-box instrument which uses solid state detectors and lasers, along with fiber optics, for beam delivery and detection. Additionally, we have provided the specifications and written verification procedures necessary for procuring a miniature multi-angle LLS instrument which will be used by the flight hardware project which resulted from this work and from this project's interaction with the laser light scattering community.

  16. Detection of Hepatozoon canis in stray dogs and cats in Bangkok, Thailand.

    Science.gov (United States)

    Jittapalapong, Sathaporn; Rungphisutthipongse, Opart; Maruyama, Soichi; Schaefer, John J; Stich, Roger W

    2006-10-01

    A rapidly increasing stray animal population in Bangkok has caused concern regarding transmission of vector-borne and zoonotic diseases. The purpose of this study was to determine if stray animals in Bangkok are a potential reservoir of Hepatozoon, a genus of tick-borne parasites that has received little attention in Thailand. Blood samples were collected from stray companion animals near monasteries in 42 Bangkok metropolitan districts. Both dogs and cats were sampled from 26 districts, dogs alone from 4 districts and cats alone from 12 districts. Samples were collected from a total of 308 dogs and 300 cats. Light microscopy and an 18 S rRNA gene-based PCR assay were used to test these samples for evidence of Hepatozoon infection. Gamonts were observed in blood smears for 2.6% of dogs and 0.7% of cats by microscopy. The PCR assay detected Hepatozoon in buffy coats from 11.4% of dogs and 32.3% of cats tested. The prevalence of infection was the same between male and female dogs or cats, and PCR-positive dogs and cats were found in 36.6% and 36.8% of the districts surveyed, respectively. There was an association between the percentages of PCR-positive dogs and cats in districts where both host species were sampled. Sequences of representative amplicons were closest to those reported for H. canis. These results represent the first molecular confirmation that H. canis is indigenous to Thailand. The unexpectedly high prevalence of Hepatozoon among stray cats indicates that their role in the epizootiology of hepatozoonosis should be investigated.

  17. STRAY DOG DETECTION IN WIRED CAMERA NETWORK

    Directory of Open Access Journals (Sweden)

    C. Prashanth

    2013-08-01

    Full Text Available Existing surveillance systems impose high level of security on humans but lacks attention on animals. Stray dogs could be used as an alternative to humans to carry explosive material. It is therefore imperative to ensure the detection of stray dogs for necessary corrective action. In this paper, a novel composite approach to detect the presence of stray dogs is proposed. The captured frame from the surveillance camera is initially pre-processed using Gaussian filter to remove noise. The foreground object of interest is extracted utilizing ViBe algorithm. Histogram of Oriented Gradients (HOG algorithm is used as the shape descriptor which derives the shape and size information of the extracted foreground object. Finally, stray dogs are classified from humans using a polynomial Support Vector Machine (SVM of order 3. The proposed composite approach is simulated in MATLAB and OpenCV. Further it is validated with real time video feeds taken from an existing surveillance system. From the results obtained, it is found that a classification accuracy of about 96% is achieved. This encourages the utilization of the proposed composite algorithm in real time surveillance systems.

  18. Prevalence of external ear disorders in Belgian stray cats.

    Science.gov (United States)

    Bollez, Anouck; de Rooster, Hilde; Furcas, Alessandra; Vandenabeele, Sophie

    2018-02-01

    Objectives Feline otitis externa is a multifactorial dermatological disorder about which very little is known. The objective of this study was to map the prevalence of external ear canal disorders and the pathogens causing otitis externa in stray cats roaming around the region of Ghent, Belgium. Methods One hundred and thirty stray cats were randomly selected during a local trap-neuter-return programme. All cats were European Shorthairs. This study included clinical, otoscopic and cytological evaluation of both external ears of each cat. Prospective data used as parameters in this study included the sex, age and body condition score of each cat, as well as the presence of nasal and/or ocular discharge, and the results of feline immunodeficiency virus (FIV) and feline leukaemia virus (FeLV) Snap tests. Results Remarkably, very few (sub)clinical problems of the external ear canal were found in the stray cat population. Malassezia species was by far the most common organism found in the external ear canals of the 130 stray cats. A total of 96/130 (74%) cats were found to have Malassezia species organisms present in one or both ears based on the cytological examination. No correlation was found between the parameters of sex, age, body condition score, the presence of nasal and/or ocular discharge and FIV and FeLV status, and the presence of parasites, bacteria or yeasts. Conclusions and relevance This study provides more information about the normal state of the external ear canal of stray cats. The ears of most stray cats are relatively healthy. The presence of Malassezia species organisms in the external ear canal is not rare among stray cats.

  19. Assessing Ultraviolet Hazards Using Portable Measuring Instruments

    Energy Technology Data Exchange (ETDEWEB)

    Ridyard, A

    2000-07-01

    The 'Erythemal Action Spectrum' shows an increase of 10{sup 3} in human skin sensitivity to UV radiation over only 30 nm of change of wavelength, from 328 nm to 298 nm. This represents a severe challenge to the manufacturing and calibration of a portable instrument which can measure the vanishingly small amounts of short wavelength UV from solarium tanning lamps, and to apply accurately an action spectra to be able to quantify the hazard presented by such lamps to skin. The classification of UV lamp types from their 'effective irradiance' requires very sharp discrimination between UV power contained in the short wavelength and the long wavelength parts of the UV spectra, so radiometers give misleading results. The only instrument suitable for making these measurements is the spectroradiometer. The development of such an instrument in a hand held portable form is described, with the difficulties associated with its calibration and such factors as stray light rejection. (author)

  20. Assessing Ultraviolet Hazards Using Portable Measuring Instruments

    International Nuclear Information System (INIS)

    Ridyard, A.

    2000-01-01

    The 'Erythemal Action Spectrum' shows an increase of 10 3 in human skin sensitivity to UV radiation over only 30 nm of change of wavelength, from 328 nm to 298 nm. This represents a severe challenge to the manufacturing and calibration of a portable instrument which can measure the vanishingly small amounts of short wavelength UV from solarium tanning lamps, and to apply accurately an action spectra to be able to quantify the hazard presented by such lamps to skin. The classification of UV lamp types from their 'effective irradiance' requires very sharp discrimination between UV power contained in the short wavelength and the long wavelength parts of the UV spectra, so radiometers give misleading results. The only instrument suitable for making these measurements is the spectroradiometer. The development of such an instrument in a hand held portable form is described, with the difficulties associated with its calibration and such factors as stray light rejection. (author)

  1. Aerial firing and stray bullet injuries: a rising tide.

    Science.gov (United States)

    Ali, Syed Asad; Tahir, Syed Mohammad; Makhdoom, Asadullah; Shaikh, Abdul Razaque; Siddique, Akmal Jamal

    2015-04-01

    Aerial firing is shooting, using fire arm, into the air usually during a celebration. This observational study aimed to quantify magnitude and impact of stray bullet injuries by aerial firing at surgical emergencies of the Liaquat University Hospital (a university hospital), Hyderabad, Sindh, Pakistan from January 2009 to December 2010 (2 years). During the study period, 144 firearm injuries due to stray bullet reported to the A and E departments of the university hospital. All patients referred to surgical unit providing emergency cover on that day irrespective of the severity of the injury for medico-legal reasons. For this study, the cases were divided into those having trivial injury and do not require any active surgical intervention and those having serious injury mandating surgical intervention. One hundred and two cases of stray bullet injury sustained trivial injury and followed as outpatients after an overnight period of indoor hospitalization; however, 42 patients with stray bullet injuries requiring surgical intervention were hospitalized. The most common events leading to aerial firing and stray bullet injuries were marriage ceremonies, followed by a political rallies and New Year celebrations. Stray bullet injury also reported after aerial firing on cricket/hockey team victories, Pakistan Independence Day (14th August), cultural day in Sindh and Basant (Kite) festival in Punjab. The most frequent sites with serious stray bullet injury were chest (15), head and neck (10), abdomen (9) and limbs (8), respectively. Surgical interventions performed included chest intubation, exploration of wound tract to retrieve bullet if lodged superficially and was palpable, laparotomy to managed intra-abdominal injury, reduction of fracture site followed by reconstruction, flap reconstruction and graft for nonhealing wound. The mean duration of hospital stay was 19 days. No mortality was observed in this series of patients. We conclude that the prevalence of aerial

  2. Monitoring dc stray current corrosion at sheet pile structures

    NARCIS (Netherlands)

    Peelen, W.H.A.; Neeft, E.A.C.; Leegwater, G.; Kanten-Roos, W. van; Courage, W.M.G.

    2012-01-01

    Steel is discarded by railway owners as a material for underground structures near railway lines, due to uncertainty over increased corrosion by DC stray currents stemming from the traction power system. This paper presents a large scale field test in which stray currents interference of a sheet

  3. The Disturbing Effect of the Stray Magnetic Fields on Magnetoimpedance Sensors

    Directory of Open Access Journals (Sweden)

    Tao Wang

    2016-10-01

    Full Text Available The disturbing effect of the stray magnetic fields of Fe-based amorphous ribbons on the giant magnetoimpedance (GMI sensor has been investigated systematically in this paper. Two simple methods were used for examining the disturbing effect of the stray magnetic fields of ribbons on the GMI sensor. In order to study the influence of the stray magnetic fields on the GMI effect, the square-shaped amorphous ribbons were tested in front, at the back, on the left and on the top of a meander-line GMI sensor made up of soft ferromagnetic films, respectively. Experimental results show that the presence of ribbons in front or at the back of GMI sensor shifts the GMI curve to a lower external magnetic field. On the contrary, the presence of ribbons on the left or on the top of the GMI sensor shifts the GMI curve to a higher external magnetic field, which is related to the coupling effect of the external magnetic field and the stray magnetic fields. The influence of the area and angle of ribbons on GMI was also studied in this work. The GMI sensor exhibits high linearity for detection of the stray magnetic fields, which has made it feasible to construct a sensitive magnetometer for detecting the typical stray magnetic fields of general soft ferromagnetic materials.

  4. The quality of stray radiation in the ovarian region in diagnostic X-ray examinations

    International Nuclear Information System (INIS)

    Ewen, K.; Fiebach, B.J.O.; Fischer, P.G.; Loehr, E.

    1976-01-01

    Dose measurements (LiF-TLD) and recordings of stray radiation spectra (Ge(Li)-Detectors) in a phantom show that shielding of the ovaries against stray radiation is advisable even though the effectivity of this measure decreases at higher tube voltages. The exposure of the ovaries to stray radiation increases with increasing tube voltage; the radiation quality of the stray radiation is, for the most part, independent of the filter value. (orig./AK) [de

  5. Stray energy transfer during endoscopy.

    Science.gov (United States)

    Jones, Edward L; Madani, Amin; Overbey, Douglas M; Kiourti, Asimina; Bojja-Venkatakrishnan, Satheesh; Mikami, Dean J; Hazey, Jeffrey W; Arcomano, Todd R; Robinson, Thomas N

    2017-10-01

    Endoscopy is the standard tool for the evaluation and treatment of gastrointestinal disorders. While the risk of complication is low, the use of energy devices can increase complications by 100-fold. The mechanism of increased injury and presence of stray energy is unknown. The purpose of the study was to determine if stray energy transfer occurs during endoscopy and if so, to define strategies to minimize the risk of energy complications. A gastroscope was introduced into the stomach of an anesthetized pig. A monopolar generator delivered energy for 5 s to a snare without contacting tissue or the endoscope itself. The endoscope tip orientation, energy device type, power level, energy mode, and generator type were varied to mimic in vivo use. The primary outcome (stray current) was quantified as the change in tissue temperature (°C) from baseline at the tissue closest to the tip of the endoscope. Data were reported as mean ± standard deviation. Using the 60 W coag mode while changing the orientation of the endoscope tip, tissue temperature increased by 12.1 ± 3.5 °C nearest the camera lens (p energy transfer (p = 0.04 and p = 0.002, respectively) as did utilizing the low-voltage cut mode (6.6 ± 0.5 °C, p energy transfer compared to a standard generator (1.5 ± 3.5 °C vs. 9.5 ± 0.8 °C, p energy is transferred within the endoscope during the activation of common energy devices. This could result in post-polypectomy syndrome, bleeding, or perforation outside of the endoscopist's view. Decreasing the power, utilizing low-voltage modes and/or an impedance-monitoring generator can decrease the risk of complication.

  6. A method to measure internal stray radiation of cryogenic infrared imaging systems under various ambient temperatures

    Science.gov (United States)

    Tian, Qijie; Chang, Songtao; Li, Zhou; He, Fengyun; Qiao, Yanfeng

    2017-03-01

    The suppression level of internal stray radiation is a key criterion for infrared imaging systems, especially for high-precision cryogenic infrared imaging systems. To achieve accurate measurement for internal stray radiation of cryogenic infrared imaging systems under various ambient temperatures, a measurement method, which is based on radiometric calibration, is presented in this paper. First of all, the calibration formula is deduced considering the integration time, and the effect of ambient temperature on internal stray radiation is further analyzed in detail. Then, an approach is proposed to measure the internal stray radiation of cryogenic infrared imaging systems under various ambient temperatures. By calibrating the system under two ambient temperatures, the quantitative relation between the internal stray radiation and the ambient temperature can be acquired, and then the internal stray radiation of the cryogenic infrared imaging system under various ambient temperatures can be calculated. Finally, several experiments are performed in a chamber with controllable inside temperatures to evaluate the effectiveness of the proposed method. Experimental results indicate that the proposed method can be used to measure internal stray radiation with high accuracy at various ambient temperatures and integration times. The proposed method has some advantages, such as simple implementation and the capability of high-precision measurement. The measurement results can be used to guide the stray radiation suppression and to test whether the internal stray radiation suppression performance meets the requirement or not.

  7. Stray capacitances in the watt balance operation: electrostatic forces

    DEFF Research Database (Denmark)

    Quagliotti, Danilo; Mana, G.

    2014-01-01

    In a watt balance, stray capacitances exist between the coil and the magnet. Since the electric current flowing in the coil creates a difference in electric potentials between the coil and magnet, their electrostatic interactions must be taken into account. This paper reports the results of a fin......In a watt balance, stray capacitances exist between the coil and the magnet. Since the electric current flowing in the coil creates a difference in electric potentials between the coil and magnet, their electrostatic interactions must be taken into account. This paper reports the results...

  8. The impact of microwave stray radiation to in-vessel diagnostic components

    Energy Technology Data Exchange (ETDEWEB)

    Hirsch, M.; Laqua, H. P.; Hathiramani, D.; Baldzuhn, J.; Biedermann, C.; Cardella, A.; Erckmann, V.; König, R.; Köppen, M.; Zhang, D. [Max-Planck-Institut für Plasmaphysik, Teilinstitut Greifswald, EURATOM Association, D-17489 Greifswald (Germany); Oosterbeek, J.; Brand, H. von der; Parquay, S. [Technische Universiteit Eindhoven, department Technische Natuurkunde, working group for Plasma Physics and Radiation Technology, Den Doelch 2, 5612 AZ Eindhoven (Netherlands); Jimenez, R. [Centro de Investigationes Energeticas, Medioambientales y Technológicas, Association EURATOM/CIEMAT, Avenida Complutense 22, Madrid 28040 (Spain); Collaboration: W7-X Teasm

    2014-08-21

    Microwave stray radiation resulting from unabsorbed multiple reflected ECRH / ECCD beams may cause severe heating of microwave absorbing in-vessel components such as gaskets, bellows, windows, ceramics and cable insulations. In view of long-pulse operation of WENDELSTEIN-7X the MIcrowave STray RAdiation Launch facility, MISTRAL, allows to test in-vessel components in the environment of isotropic 140 GHz microwave radiation at power load of up to 50 kW/m{sup 2} over 30 min. The results show that both, sufficient microwave shielding measures and cooling of all components are mandatory. If shielding/cooling measures of in-vessel diagnostic components are not efficient enough, the level of stray radiation may be (locally) reduced by dedicated absorbing ceramic coatings on cooled structures.

  9. Stray current monitoring at Nuremberg subway; Streustromueberwachung bei der U-Bahn Nuernberg

    Energy Technology Data Exchange (ETDEWEB)

    Altmann, M.; Halfmann, U.; Schneider, E. [Siemens AG, Erlangen (Germany). TS EL EN 2; Roesch, N. [VAG Verkehrs-AG Nuernberg, FA/SA - Starkstromanlagen, Nuernberg (Germany)

    2004-05-01

    Operating DC traction systems requires protective measures against the effects of stray currents. Damage by corrosion could occur both at railway and third party installations. The continuous effectiveness of protective measures needs to be monitored and recorded during revenue operation, and shall be capable to be demonstrated to supervising authorities. Measuring the rail-to-earth potential within the traction network under operational conditions, combined with centralized analysis, visualization, signaling and archiving is a straightforward and efficient method of stray current monitoring. For more than one year, the stray current monitoring system SITRAS SMS {sup registered} has been undergoing successful field application at the Nuremberg Subway. (orig.)

  10. A degradation model for stray current induced corrosion in underground reinforced concrete structures

    NARCIS (Netherlands)

    Polder, R.B.; Peelen, W.H.A.

    2003-01-01

    This paper describes the effects of stray currents on durability and reinforcement corrosion of underground concrete structures. Cathodic protection of underground pipelines are stationary sources of stray current interference with concrete, and rail traction systems are non-stationary sources. The

  11. Electrolytic corrosion of water pipeline system in the remote distance from stray currents—Case study

    Directory of Open Access Journals (Sweden)

    Krzysztof Zakowski​

    2016-06-01

    Full Text Available Case study of corrosion failure of urban water supply system caused by the harmful effects of stray currents was presented. The failure occurred at a site distant from the sources of these currents namely the tramway and railway traction systems. Diagnosis revealed the stray currents flow to pipeline over a remote distance of 800/1000 m from the point of failure. At the point of failure stray currents flowed from the pipeline to the ground through external insulation defects, causing the process of electrolytic corrosion of the metal. Long distance between the affected section of the pipeline and the sources of stray currents excludes the typical protection against stray currents in the form of electrical polarized drainage. Corrosion protection at this point can be achieved by using the earthing electrodes made of magnesium, which will also provide cathodic current protection as galvanic anode.

  12. A survey of gastrointestinal helminth of stray dogs in Zabol city, southeastern of Iran

    Directory of Open Access Journals (Sweden)

    Geraili, A.

    2016-03-01

    Full Text Available Canids are reservoir for some zoonoses helminthic disease. They are one of main public health problem. The aim of this study was to ascertain frequency of gastrointestinal helminthic infection of stray dogs in Zabol city, southeaster of Iran. In this descriptive study, 30 stray dogs were euthanized, intestine was removed by necropsy. Then, the intestines was opened by scalpel and their contents passed through mesh sieve. The helminth were collected. The nematodes were preserved in 70% ethanol with 5% glycerin and cestodes were preserved in 70% ethanol. The cestodes were stained by acetocarmine. The nematodes were cleared by lactophenol. The genus and species of helminth were identified by identification keys. Twenty two (73.3% of stray dogs had at least one intestinal helminthic infection. Recovered helminth from stray dogs include: Taenia hydatigena (53.3%, Taenia ovis (20%, Taenia multiceps (6.6%, Mesocestoides spp (10%, Toxocara canis (23.3%, Toxocara cati (3.3%. Data showed that the stray dogs in Zabol city harbor some important zoonoses helminth parasite like Toxocara.

  13. Stray-electron accumulation and effects in HIF accelerators

    International Nuclear Information System (INIS)

    Cohen, R.H.; Friedman, A.; Furman, M.A.; Lund, S.M.; Molvik, A.W.; Stoltz, P.; Vay, J.-L.

    2003-01-01

    Stray electrons can be introduced in positive-charge accelerators for heavy ion fusion (or other applications) as a result of ionization of ambient gas or gas released from walls due to halo-ion impact, or as a result of secondary-electron emission. Electron accumulation is impacted by the ion beam potential, accelerating fields, multipole magnetic fields used for beam focus, and the pulse duration. We highlight the distinguishing features of heavy-ion accelerators as they relate to stray-electron issues, and present first results from a sequence of simulations to characterize the electron cloud that follows from realistic ion distributions. Also, we present ion simulations with prescribed random electron distributions, undertaken to begin to quantify the effects of electrons on ion beam quality

  14. A preview of a microgravity laser light scattering instrument

    Science.gov (United States)

    Meyer, W. V.; Ansari, R. R.

    1991-01-01

    The development of a versatile, miniature, modular light scattering instrument to be used in microgravity is described. The instrument will measure microscopic particles in the size range of thirty angstroms to above three microns. This modular instrument permits several configurations, each optimized for a particular experiment. In particular, a multiangle instrument will probably be mounted in a rack in the Space Shuttle and on the Space Station. It is possible that a Space Shuttle glove-box and a lap-top computer containing a correlator card can be used to perform a number of experiments and to demonstrate the technology needed for more elaborate investigations.

  15. [Scattered light and glare sensitivity after wavefront-guided photorefractive keratectomy (WFG-PRK) and laser in situ keratomileusis (WFG-LASIK)].

    Science.gov (United States)

    Vignal, R; Tanzer, D; Brunstetter, T; Schallhorn, S

    2008-05-01

    To compare glare sensitivity measured by the intraocular scattered light between WFG-PRK and WFG-LASIK at 12 months follow-up and to assess its correlation to patients' complaints. Prospective and randomized study on 13 patients treated with WFG-LASIK, 13 patients with WFG-PRK and a control group of 35 patients. The intraocular stray light was measured by the Oculus C-Quant 12 months after surgery and before surgery for the control group. Photopic and mesopic contrast acuity and glare symptoms were reported pre- and postoperatively. Stray light values were normal in 79% of patients after WFG-LASIK and PRK and 86% in the control group, with mean values of 1.05 log, 1.03 log, and 0.99 log, respectively (p>0.05). All the patients with significant glare complaints had impaired stray light values versus 31.5% in the no-complaint group. Photopic and mesopic contrast acuity and glare symptoms were improved 1 year after surgery compared to preoperatively (no significant difference between groups). WFG-LASIK and PRK are safe and equivalent procedures regarding quality of vision. The measurement of stray light can be a discriminative test to assessing patients' glare complaints.

  16. 30 CFR 75.1719-3 - Methods of measurement; light measuring instruments.

    Science.gov (United States)

    2010-07-01

    ... being measured and a sufficient distance from the surface to allow the light sensing element in the... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Methods of measurement; light measuring... § 75.1719-3 Methods of measurement; light measuring instruments. (a) Compliance with § 75.1719-1(d...

  17. Experimental observations of stray current effects on steel fibres embedded in mortar

    DEFF Research Database (Denmark)

    Solgaard, A.O.S.; Carsana, M.; Geiker, M.R.

    2013-01-01

    It is known that stray direct current can cause corrosive damage over time to bar reinforced concrete, but knowledge on the consequences to steel fibre reinforced concrete is limited. This paper presents analyses and corresponding results from an experimental program (parametric study) investigat......It is known that stray direct current can cause corrosive damage over time to bar reinforced concrete, but knowledge on the consequences to steel fibre reinforced concrete is limited. This paper presents analyses and corresponding results from an experimental program (parametric study......) investigating the conditions required for current to be picked up by embedded steel fibres or reinforcement (rebars). The experiments showed that there is a clear ‘length effect’ related to the susceptibility of stray current being picked up by embedded steel (fibres or rebars): the shorter the reinforcement...

  18. Stray dog and cat laws and enforcement in Czech Republic and in Italy

    Directory of Open Access Journals (Sweden)

    Eva Voslářvá

    2012-01-01

    Full Text Available The growing numbers of stray dogs and cats have posed serious public-health, socioeconomic, political and animal-welfare problems in many EU countries. Stray animal population control is a complex issue and there are no easy solutions. Recognising the importance of the issue the European Commission has, since 2007, actively contributed to the elaboration of the first global welfare standards for the control of dog populations in the framework of the World Organisation for Animal Health (OIE. Problem-solving approaches vary in different countries as there is no common European Community legislation dealing with stray animal control. In this paper the authors describe the characteristics of the stray dog and cat problem in general and focus on existing European legislation. A comparative overview of policies and measures in place in the Czech Republic and in Italy is made to observe the differences between the two countries and understand the different needs in each, considering their historical and social differences (i.e. a post-communist eastern country vs a western country and founder member of what is now the European Union.

  19. Searching for O-X-B mode-conversion window with monitoring of stray microwave radiation in LHD

    International Nuclear Information System (INIS)

    Igami, H.; Kubo, S.; Laqua, H. P.; Nagasaki, K.; Inagaki, S.; Notake, T.; Shimozuma, T.; Yoshimura, Y.; Mutoh, T.; LHD Experimental Group

    2006-01-01

    In the Large Helical Device, the stray microwave radiation is monitored by using so-called sniffer probes during electron cyclotron heating. In monitoring the stray radiation, we changed the microwave beam injection angle and search the O-X-B mode-conversion window to excite electron Bernstein waves (EBWs). When the microwave beam is injected toward the vicinity of the predicted O-X-B mode-conversion window, the electron temperature rises in the central part of overdense plasmas. In that case, the stray radiation level near the injection antenna becomes low. These results indicate that monitoring the stray radiation near the injection antenna is helpful in confirming the effectiveness of excitation of EBWs simply without precise analysis

  20. Enabling instrumentation and technology for 21st century light sources

    Energy Technology Data Exchange (ETDEWEB)

    Byrd, J.M.; Shea, T.J.; Denes, P.; Siddons, P.; Attwood, D.; Kaertner, F.; Moog, L.; Li, Y.; Sakdinawat, A.; Schlueter, R.

    2010-06-01

    We present the summary from the Accelerator Instrumentation and Technology working group, one of the five working groups that participated in the BES-sponsored Workshop on Accelerator Physics of Future Light Sources held in Gaithersburg, MD September 15-17, 2009. We describe progress and potential in three areas: attosecond instrumentation, photon detectors for user experiments, and insertion devices.

  1. FACT light collection - solid light concentrators in Cherenkov Astronomy

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Isabel [ETH Zurich, Institute for Particle Physics, CH-8093 Zurich (Switzerland); Collaboration: FACT-Collaboration

    2011-07-01

    Pixelized cameras of Imaging Atmospheric Cherenkov Telescopes use hollow light guides with reflective surfaces based on the Winston cone design. These cones minimize insensitive spaces between the photo sensors and shield the camera from stray background light by limiting the angular acceptance to the primary reflector area. FACT (First G-APD Cherenkov Telescope) will be the first IACT with Geiger-mode avalanche photodiodes as light sensors. Solid light concentrators complementing these sensors will be used instead of hollow Winston cones. We will present simulations and measurements of our light collector design, which was optimized for the requirements of the FACT telescope and detector, and discuss the specific differences to more traditional solutions.

  2. Seroepidemiological survey of helminthic parasites of stray dogs in Sari City, northern Iran.

    Science.gov (United States)

    Gholami, Ishirzad; Daryani, Ahmad; Sharif, Mehdi; Amouei, Afsaneh; Mobedi, Iraj

    2011-01-15

    The objective of this study was to determine the prevalence rate of helminthic parasites in stray dogs' population especially zoonotic infections and to identify potential risk factors in the different areas of Sari city in Caspian area, north of Iran. During the period from April to September 2007, 50 stray dogs were collected from urban areas of Sari city. Recovered parasites were fixed in alcohol and stained by carmine then observed by microscope. The taxonomic study was carried out by measuring different parts of the body of helminthes and statistical tests were performed using the Chi-square test. A total of 27 adult and 23 juvenile stray dogs were collected and the overall prevalence rate of infection was 90%. The three most common helminthes were Toxocara canis (60%), Ancylostoma caninum (46%) and Dipylidium caninum (36%). Other parasites were Uncinaria stenocephala (12%), Taenia hydatigena (6%), Spirocerca lupi (6%), Dirofilaria immitis (6%), Toxascaris leonina (2%), Rictularia sp. (2%), Taenia ovis (2%) and Taenia taeniformis (2%). Five species of zoonotic helminthes recovered were T. canis, A. caninum, U. stenocephala, D. caninum and D. immitis. Hookworm infections (58%) were more common significantly in the young stray dogs (p caninum, T. canis and U. stenocephala, there was significant difference between juvenile and adult dogs (p < 0.05). The results highlight the potential role of stray dogs for transmission of helminthic parasites particularly zoonotic parasites that are a significant risk to human health.

  3. The Focal Plane Assembly for the Athena X-Ray Integral Field Unit Instrument

    Science.gov (United States)

    Jackson, B. D.; Van Weers, H.; van der Kuur, J.; den Hartog, R.; Akamatsu, H.; Argan, A.; Bandler, S. R.; Barbera, M.; Barret, D.; Bruijn, M. P.; hide

    2016-01-01

    This paper summarizes a preliminary design concept for the focal plane assembly of the X-ray Integral Field Unit on the Athena spacecraft, an imaging microcalorimeter that will enable high spectral resolution imaging and point-source spectroscopy. The instrument's sensor array will be a 3840-pixel transition edge sensor (TES) microcalorimeter array, with a frequency domain multiplexed SQUID readout system allowing this large-format sensor array to be operated within the thermal constraints of the instrument's cryogenic system. A second TES detector will be operated in close proximity to the sensor array to detect cosmic rays and secondary particles passing through the sensor array for off-line coincidence detection to identify and reject events caused by the in-orbit high-energy particle background. The detectors, operating at 55 mK, or less, will be thermally isolated from the instrument cryostat's 2 K stage, while shielding and filtering within the FPA will allow the instrument's sensitive sensor array to be operated in the expected environment during both on-ground testing and in-flight operation, including stray light from the cryostat environment, low-energy photons entering through the X-ray aperture, low-frequency magnetic fields, and high-frequency electric fields.

  4. WIDESPREAD OF STRAY DOGS: METHODS FOR SOLVING THE PROBLEM IN CERTAIN REGIONS OF BOSNIA AND HERZEGOVINA

    OpenAIRE

    Muhamed Katica; Nedzad Gradascevic; Nejra Hadzimusic; Zarema Obradovic; Ramo Mujkanovic; Esad Mestric; Senad Coloman; Muhamed Dupovac

    2017-01-01

    Stray dogs are the ones not microchipped, which live across the streets and other public surfaces unattended, and so represent a serious public-health problem. Lack of human support for the stray dogs causes a range of problems - from territorial status to ensuring food. Such conditions force them to activate a self-preservation mechanism and return to natural behavioral patterns. Regarding the fact that several thousands of stray dogs were recorded in observed regions of Bosnia and Herze...

  5. Development of a versatile laser light scattering instrument

    Science.gov (United States)

    Meyer, William V.; Ansari, Rafat R.

    1990-10-01

    A versatile laser light scattering (LLS) instrument is developed for use in microgravity to measure microscopic particles of 30 A to above 3 microns. Since it is an optical technique, LLS does not affect the sample being studied. A LLS instrument built from modules allows several configurations, each optimized for a particular experiment. The multiangle LLS instrument can be mounted in the rack in the Space Shuttle and on Space Station Freedom. It is possible that a Space Shuttle glove-box and a lap-top computer containing a correlator card can be used to perform a number of experiments and to demonstrate the technology needed for more elaborate investigations. This offers simple means of flying a great number of experiments without the additional requirements of full-scale flight hardware experiments.

  6. The Atomic, Molecular and Optical Science instrument at the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Ferguson, Ken R. [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Department of Applied Physics, Stanford University, 348 Via Pueblo, Stanford, CA 94305 (United States); Bucher, Maximilian; Bozek, John D.; Carron, Sebastian; Castagna, Jean-Charles [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Coffee, Ryan [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Pulse Institute, Stanford University and SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Curiel, G. Ivan; Holmes, Michael; Krzywinski, Jacek; Messerschmidt, Marc; Minitti, Michael; Mitra, Ankush; Moeller, Stefan; Noonan, Peter; Osipov, Timur; Schorb, Sebastian; Swiggers, Michele; Wallace, Alexander; Yin, Jing [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Bostedt, Christoph, E-mail: bostedt@slac.stanford.edu [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Pulse Institute, Stanford University and SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States)

    2015-04-17

    A description of the Atomic, Molecular and Optical Sciences (AMO) instrument at the Linac Coherent Light Source is presented. Recent scientific highlights illustrate the imaging, time-resolved spectroscopy and high-power density capabilities of the AMO instrument. The Atomic, Molecular and Optical Science (AMO) instrument at the Linac Coherent Light Source (LCLS) provides a tight soft X-ray focus into one of three experimental endstations. The flexible instrument design is optimized for studying a wide variety of phenomena requiring peak intensity. There is a suite of spectrometers and two photon area detectors available. An optional mirror-based split-and-delay unit can be used for X-ray pump–probe experiments. Recent scientific highlights illustrate the imaging, time-resolved spectroscopy and high-power density capabilities of the AMO instrument.

  7. An Exploration into Integrating Daylight and Artificial Light via an Observational Instrument

    DEFF Research Database (Denmark)

    Petersen, Kjell Yngve; Søndergaard, Karin

    2015-01-01

    An Exploration into Integrating Daylight and Artificial Light via an Observational Instrument Daylight is dynamic and dependent upon weather conditions; unfolding with both subtle and dramatic variations in qualities of light. Through a building’s apertures, daylight creates a connection between...... abstract and blurred phenomena, these diffused luminous reflections rouse us into interactions with the world. In this book we are interested in identifying the qualitative parameters involved in the integration of dynamic artificial lighting and daylight; the latter being already highly dynamic by nature...... that examine how the dynamic artificial lighting in the observational instrument unfolds during the changing of the daylight situations that are generated by the weather outside. This research employs the concept of coupling between interior and exterior, in order to identify a spectrum of design parameters...

  8. Monitoring millimeter wave stray radiation during ECRH operation at ASDEX Upgrade

    Science.gov (United States)

    Schubert, M.; Honecker, F.; Monaco, F.; Schmid-Lorch, D.; Schütz, H.; Stober, J.; Wagner, D.

    2012-09-01

    Due to imperfection of the single path absorption, ECRH at ASDEX Upgrade (AUG) is always accompanied by stray radiation in the vacuum vessel. New ECRH scenarios with O2 and X3 heating schemes extend the operational space, but they have also the potential to increase the level of stray radiation. There are hazards for invessel components. Damage on electric cables has already been encountered. It is therefore necessary to monitor and control the ECRH with respect to the stray radiation level. At AUG a system of Sniffer antennas equipped with microwave detection diodes is installed. The system is part of the ECRH interlock circuit. We notice, however, that during plasma operation the variations of the Sniffer antenna signal are very large. In laboratory measurements we see variations of up to 20 dB in the directional sensitivity and we conclude that an interference pattern is formed inside the copper sphere of the antenna. When ECRH is in plasma operation at AUG, the plasma is acting as a phase and mode mixer for the millimeter waves and thus the interference pattern inside the sphere changes with the characteristic time of the plasma dynamics. In order to overcome the difficulty of a calibrated measurement of the average stray radiation level, we installed bolometer and pyroelectric detectors, which intrinsically average over interference structures due to their large active area. The bolometer provides a robust calibration but with moderate temporal resolution. The pyroelectric detector provides high sensitivity and a good temporal resolution, but it raises issues of possible signal drifts in long pulses.

  9. Monitoring millimeter wave stray radiation during ECRH operation at ASDEX Upgrade

    Directory of Open Access Journals (Sweden)

    Wagner D.

    2012-09-01

    Full Text Available Due to imperfection of the single path absorption, ECRH at ASDEX Upgrade (AUG is always accompanied by stray radiation in the vacuum vessel. New ECRH scenarios with O2 and X3 heating schemes extend the operational space, but they have also the potential to increase the level of stray radiation. There are hazards for invessel components. Damage on electric cables has already been encountered. It is therefore necessary to monitor and control the ECRH with respect to the stray radiation level. At AUG a system of Sniffer antennas equipped with microwave detection diodes is installed. The system is part of the ECRH interlock circuit. We notice, however, that during plasma operation the variations of the Sniffer antenna signal are very large. In laboratory measurements we see variations of up to 20 dB in the directional sensitivity and we conclude that an interference pattern is formed inside the copper sphere of the antenna. When ECRH is in plasma operation at AUG, the plasma is acting as a phase and mode mixer for the millimeter waves and thus the interference pattern inside the sphere changes with the characteristic time of the plasma dynamics. In order to overcome the difficulty of a calibrated measurement of the average stray radiation level, we installed bolometer and pyroelectric detectors, which intrinsically average over interference structures due to their large active area. The bolometer provides a robust calibration but with moderate temporal resolution. The pyroelectric detector provides high sensitivity and a good temporal resolution, but it raises issues of possible signal drifts in long pulses.

  10. Simplified magnetic circuit for the calculation of the stray magnetic flux through the shell gaps

    Energy Technology Data Exchange (ETDEWEB)

    Collarin, P.; Piovan, R. [Associazioni EURATOM-ENEA-CNR-Univ. di Padova (Italy). Gruppo di Padova per Ricerche sulla Fusione

    1995-12-31

    Significant toroidal magnetic field perturbations, stray flux at the shell gaps and current mismatching in the coils of the toroidal field winding are measured during the start-up and the flat-top phases of RFX. These phenomena are consistent with large and wall locked MHD modes: at first some m = 1 modes evolve separately one after the other, afterwards they concur to a wide and localized plasma perturbation that persists during the flat-top. These perturbations are heavily influenced by the stray magnetic flux through the shell gaps. Hence a magnetic circuit that mainly considers the magnetic reluctance of the conducting shell gaps has been developed in order to estimate this stray flux and, therefore, to evaluate the stabilizing capability of the shell. The observation of the MHD modes, the description of the equivalent magnetic network, the estimation of the stray flux and the comparison with the experimental measurements are reported in the paper.

  11. Simplified magnetic circuit for the calculation of the stray magnetic flux through the shell gaps

    International Nuclear Information System (INIS)

    Collarin, P.; Piovan, R.

    1995-01-01

    Significant toroidal magnetic field perturbations, stray flux at the shell gaps and current mismatching in the coils of the toroidal field winding are measured during the start-up and the flat-top phases of RFX. These phenomena are consistent with large and wall locked MHD modes: at first some m = 1 modes evolve separately one after the other, afterwards they concur to a wide and localized plasma perturbation that persists during the flat-top. These perturbations are heavily influenced by the stray magnetic flux through the shell gaps. Hence a magnetic circuit that mainly considers the magnetic reluctance of the conducting shell gaps has been developed in order to estimate this stray flux and, therefore, to evaluate the stabilizing capability of the shell. The observation of the MHD modes, the description of the equivalent magnetic network, the estimation of the stray flux and the comparison with the experimental measurements are reported in the paper

  12. Intercomparison of radiation protection devices in a high-energy stray neutron field. Part III: Instrument response

    CERN Document Server

    Silari, M; Beck, P; Bedogni, R; Cale, E; Caresana, M; Domingo, C; Donadille, L; Dubourg, N; Esposito, A; Fehrenbacher, G; Fernández, F; Ferrarini, M; Fiechtner, A; Fuchs, A; García, M J; Golnik, N; Gutermuth, F; Khurana, S; Klages, Th; Latocha, M; Mares, V; Mayer, S; Radon, T; Reithmeier, H; Rollet, S; Roos, H; Rühm, W; Sandri, S; Schardt, D; Simmer, G; Spurný, F; Trompier, F; Villa-Grasa, C; Weitzenegger, E; Wiegel, B; Wielunski, M; Wissmann, F; Zechner, A; Zielczyński, M

    2009-01-01

    The European Commission has funded within its 6th Framework Programme a three-year project (2005–2007) called CONRAD, COordinated Network for RAdiation Dosimetry. The organizational framework for this project was provided by the European radiation Dosimetry Group EURADOS. Work Package 6 of CONRAD dealt with “complex mixed radiation fields at workplaces” and in this context it organised a benchmark exercise, which included both measurements and calculations, in a stray radiation field at a high-energy particle accelerator at GSI, Germany. The aim was to intercompare the response of several types of active detectors and passive dosemeters in a well-characterised workplace field. The Monte Carlo simulations of the radiation field and the experimental determination of the neutron spectra with various Bonner Sphere Spectrometers are discussed in Rollet et al. (2008) and in Wiegel et al. (2008). This paper focuses on the intercomparison of the response of the dosemeters in terms of ambient dose equivalent. Th...

  13. Seroprevalence of Ehrlichia canis infection in stray dogs from Serbia

    Directory of Open Access Journals (Sweden)

    Nataša Bogićević

    2017-03-01

    Full Text Available Canine Monocytic Ehrlichiosis is a zoonotic bacterial disease with worldwide distribution. With regards to the population of stray dogs, the disease is facilitated due to their lifestyle and the lack of anti-parasitic protection. The aim of this study was to provide serological data on the presence of a specific Ehrlichia canis IgG antibodies in stray dogs, originating from 7 municipalities in Serbia. During the period from April 2013 to June 2014, 217 canine sera were submitted to the laboratory of the Department of Infectious Diseases of Animals and Bees, Faculty of Veterinary Medicine in Belgrade. An immunofluorescent antibody test (IFAT was performed to detect antibodies to Ehrlichia canis (cut off, 1:50. Seropositive dogs were found in 5 out of 7 counties with a seroprevalence varying from 3.57% to 20% and an overall seroprevalence of 11.06% (24/217. There was no statistically significant difference between the prevalence of infection and the host age or gender. Results showed that stray dogs contribute to maintaining and spreading of Ehrlichia canis in Serbia. Due to the close relationship between people and dogs, it is of great importance to constantly monitor and improve prevention of this disease.

  14. PCR-Based Molecular Characterization of Toxocara spp. Using Feces of Stray Cats: A Study from Southwest Iran

    OpenAIRE

    Khademvatan, Shahram; Rahim, Fakher; Tavalla, Mahdi; Abdizadeh, Rahman; Hashemitabar, Mahmoud

    2013-01-01

    Feces of stray cat are potential sources of gastrointestinal parasites and play a crucial role in spreading and transmitting parasite eggs, larvae, and oocysts through contamination of soil, food, or water. In this study, we investigated the prevalence of Toxocara spp. infection in stray cats in Ahvaz city, southwest Iran. Eggs of Toxocara spp. in feces of stray cats were detected by the sucrose flotation method, and identification was conducted by polymerase chain reaction (PCR) and DNA sequ...

  15. Convergence of highly parallel stray field calculation using the fast multipole method on irregular meshes

    Science.gov (United States)

    Palmesi, P.; Abert, C.; Bruckner, F.; Suess, D.

    2018-05-01

    Fast stray field calculation is commonly considered of great importance for micromagnetic simulations, since it is the most time consuming part of the simulation. The Fast Multipole Method (FMM) has displayed linear O(N) parallelization behavior on many cores. This article investigates the error of a recent FMM approach approximating sources using linear—instead of constant—finite elements in the singular integral for calculating the stray field and the corresponding potential. After measuring performance in an earlier manuscript, this manuscript investigates the convergence of the relative L2 error for several FMM simulation parameters. Various scenarios either calculating the stray field directly or via potential are discussed.

  16. A study on protozoan infections (Giardia, Entamoeba, Isoapora and Cryptosporidium in stray dogs in Ilam province

    Directory of Open Access Journals (Sweden)

    S Kakekhani

    2011-11-01

    Full Text Available Giardia, Entamoeba, Isospora and Cryptosporidium are important protozoan parastites that caused diarrhea in human and animals. In the present study, fecal samples were collected fresh, directly from the rectum of 112 stray dogs in Ilam province. Giardia and Entamoeba were concentrated by using the formalin ether sedimentation method followed by the trichrome and iodine staining technique andCryptosporidium  oocysts  were  concentrated  by  using  the  formalin  ether  sedimentation  method  followed by the modified Ziehl-Neelsen staining technique. Of 112 stray dogs, protozoan infections were detected from feces of 46 dogs (41.07% that Giardia infection was detected from feces of 21 dogs (18.75%, Isospora 17 (15.17%, Cryptosporidium 8 (7.14% and synchronization infection to 2 protozoan in 9 dogs (8.03% and to 3 protozoan in 3 (2.67%. In the present study not observed to Entamoeba. No statistically significant differences in prevalence of protozoan parasites occurred between female (34.21 % and male (55.5 % stray dogs (p>0/05. But statistically significant differences in prevalence occurred between 1≥0 and 0 ≥1 stray dogs (p>0/05. So that stray dogs of Ilam province can cause infection of human water and food sources.

  17. 4th generation light source instrumentation

    International Nuclear Information System (INIS)

    Lumpkin, A.

    1998-01-01

    This working group on 4th Generation Light Source (4GLS) Instrumentation was a follow-up to the opening-discussion on Challenges in Beam Profiling. It was in parallel with the Feedback Systems session. We filled the SSRL Conference Room with about 25 participants. The session opened with an introduction by Lumpkin. The target beam parameter values for a few-angstrom, self-amplified spontaneous emissions (SASE) experiment and for a diffraction-limited soft x-ray storage ring source were addressed. Instrument resolution would of course need to be 2-3 times better than the value measured, if possible. The nominal targeted performance parameters are emittance (1-2π mm mrad), bunch length (100 fs), peak-current (l-5 kA), beam size (10 microm), beam divergence (1 microrad), energy spread (2 x 10 -4 ), and beam energy (10's of GeV). These are mostly the SASE values, and the possible parameters for a diffraction-limited soft x-ray source would be relaxed somewhat. Beam stability and alignment specifications in the sub-micron domain for either device are anticipated

  18. Internal stray radiation measurement for cryogenic infrared imaging systems using a spherical mirror.

    Science.gov (United States)

    Tian, Qijie; Chang, Songtao; He, Fengyun; Li, Zhou; Qiao, Yanfeng

    2017-06-10

    Internal stray radiation is a key factor that influences infrared imaging systems, and its suppression level is an important criterion to evaluate system performance, especially for cryogenic infrared imaging systems, which are highly sensitive to thermal sources. In order to achieve accurate measurement for internal stray radiation, an approach is proposed, which is based on radiometric calibration using a spherical mirror. First of all, the theory of spherical mirror design is introduced. Then, the calibration formula considering the integration time is presented. Following this, the details regarding the measurement method are presented. By placing a spherical mirror in front of the infrared detector, the influence of internal factors of the detector on system output can be obtained. According to the calibration results of the infrared imaging system, the output caused by internal stray radiation can be acquired. Finally, several experiments are performed in a chamber with controllable inside temperatures to validate the theory proposed in this paper. Experimental results show that the measurement results are in good accordance with the theoretical analysis, and demonstrate that the proposed theories are valid and can be employed in practical applications. The proposed method can achieve accurate measurement for internal stray radiation at arbitrary integration time and ambient temperatures. The measurement result can be used to evaluate whether the suppression level meets the system requirement.

  19. A Light-Weight Instrumentation System Design

    International Nuclear Information System (INIS)

    Kidner, Ronald

    1999-01-01

    To meet challenging constraints on telemetry system weight and volume, a custom Light-Weight Instrumentation System was developed to collect vehicle environment and dynamics on a short-duration exo-atmospheric flight test vehicle. The total telemetry system, including electronics, sensors, batteries, and a 1 watt transmitter weighs about 1 kg. Over 80 channels of measurement, housekeeping, and telemetry system diagnostic data are transmitted at 128 kbps. The microcontroller-based design uses the automotive industry standard Controller Area Network to interface with and support in-flight control fimctions. Operational parameters are downloaded via a standard asynchronous serial communications intefiace. The basic design philosophy and functionality is described here

  20. RECENT BEAM MEASUREMENTS AND NEW INSTRUMENTATION AT THE ADVANCED LIGHT SOURCE

    International Nuclear Information System (INIS)

    Sannibale, Fernando; Baptiste, Kenneth; Barry, Walter; Chin, Michael; Filippetto, Daniele; Jaegerhofer, Lukas; Julian, James; Kwiatkowski, Slawomir; Low, Raymond; Plate, David; Portmann, Gregory; Robin, David; Scarvie, Tomas; Stupakov, Gennady; Weber, Jonah; Zolotorev, Max

    2008-01-01

    The Advanced Light Source (ALS) in Berkeley was the first of the soft x-ray third generation light source ever built, and since 1993 has been in continuous and successful operation serving a large community of users in the VUV and soft x-ray community. During these years the storage ring underwent through several important upgrades that allowed maintaining the performance of this veteran facility at the forefront. The ALS beam diagnostics and instrumentation have followed a similar path of innovation and upgrade and nowadays include most of the modem and last generation devices and technologies that are commercially available and used in the recently constructed third generation light sources. In this paper we will not focus on such already widely known systems, but we will concentrate our effort in the description of some measurements techniques, instrumentation and diagnostic systems specifically developed at the ALS and used during the last few years

  1. It’s a Dog’s Life: International Tourists’ Perceptions of the Stray Dog Population of Bhutan.

    Directory of Open Access Journals (Sweden)

    Paul C Strickland

    2015-12-01

    Full Text Available This study investigates the international tourists’ perception of the stray dog population of Bhutan as little or no mention of the increasing stray dog population and their impact on tourism has been documented. After personally visiting the Kingdom on many occasions, it is evident that the stray dog population is increasing in dog numbers in major cities. The problems arising are negative comments by tourists relating to the stray dog population that are starting to appear in social media that may impact the visitor experience and the perception of Bhutan’s tourism industry. Veterinary science is aware of both increasing dog populations and the control of diseases such as Rabies however the author can find no evidence regarding challenges for the tourism industry. The problem is aided by no local veterinary clinics, no laws regarding dog governance, little funding for sterilization programs and being predominately a Buddhist country that cannot ‘cull’ animals. Using qualitative analysis from international tourist focus groups who were visiting Bhutan, this study highlights the perceptions of tourists regarding the stray dog population and how it may impact on visitor expectations. The paper suggests options that local government, Bhutanese nationals and visitors can do to assist the issue based on visitor feedback. Future research may include comparisons with other cities or countries to examine if it is a global issue or unique to Bhutan.

  2. Identification of Zoonotic Parasites isolated from Stray Dogs in Bojnurd County Located in North-East of Iran

    Directory of Open Access Journals (Sweden)

    Kourosh Arzamani

    2016-10-01

    Full Text Available Dog can represent as an important source of zoonotic disease and important health problem for human. They can carry dangerous parasitic diseases such as hydatidosis, toxocariasis and Coenurus cerebralis to humans and animals. This study was performed in order to determine the prevalence and intensity of zoonotic parasites among stray dogs from Bojnurd, the capital city of North Khorasan province in North West of Iran. During a program performing by Bojnurd municipal on the slow killing of stray dogs, 32 dogs from Jun 2013 till March 2015 were selected. At necropsy their alimentary canals were removed and to identify the species of helminthes, the nematodes were cleared in lactophenol and cestodes were stained using carmine acid. Intestinal protozoan parasites were detected with parasitological methods. 28 (87.5% of 32 stray dogs infected at least with one helminth. Seven species of cestodes were isolated from examined dogs and three species of nematode were detected. Giardia sp. and Cryptosporidium sp. detected from fecal samples. This is the first study of the prevalence of intestinal zoonotic parasites in dogs in this area. It seems control of bearing stray dogs can help human health and reduction economic losses caused by stray dog’s zoonotic parasites.

  3. Bartonella and Toxoplasma Infections in Stray Cats from Iraq

    Science.gov (United States)

    Switzer, Alexandra D.; McMillan-Cole, Audrey C.; Kasten, Rickie W.; Stuckey, Matthew J.; Kass, Philip H.; Chomel, Bruno B.

    2013-01-01

    Because of overpopulation, stray/feral cats were captured on military bases in Iraq as part of the US Army Zoonotic Disease Surveillance Program. Blood samples were collected from 207 cats, mainly in Baghdad but also in North and West Iraq, to determine the prevalence of Bartonella and Toxoplasma infections. Nine (4.3%) cats, all from Baghdad, were bacteremic with B. henselae type I. Seroprevalence was 30.4% for T. gondii, 15% for B. henselae, and 12.6% for B. clarridgeiae. Differences in Bartonella prevalence by location were statistically significant, because most of the seropositive cats were from Baghdad. There was no association between T. gondii seropositivity and either of the two Bartonella species surveyed. This report is the first report on the prevalence of Bartonella and T. gondii among stray cats in Iraq, which allows for better evaluation of the zoonotic risk potential to the Iraqi people and deployed military personnel by feral cat colonies. PMID:24062480

  4. Problems Associated with the Microchip Data of Stray Dogs and Cats Entering RSPCA Queensland Shelters

    Science.gov (United States)

    Lancaster, Emily; Rand, Jacquie; Collecott, Sheila; Paterson, Mandy

    2015-01-01

    Simple Summary Microchip identification has become an important tool to reunite stray dogs and cats with their owners, and is now compulsory in most states of Australia. Improvement of the microchipping system in Australia is limited by a lack of published Australian data documenting the problems experienced by shelter staff when using microchip data to contact the owner of a stray animal. In this study we determine the character and frequency of inaccurate microchip data to identify weaknesses in the current microchipping system. This information could be used to develop strategies that increase the accuracy of microchip data that will increase the reclaiming of stray animals. Abstract A lack of published information documenting problems with the microchip data for the reclaiming of stray animals entering Australian shelters limits improvement of the current microchipping system. A retrospective study analysing admission data for stray, adult dogs (n = 7258) and cats (n = 6950) entering the Royal Society for the Prevention of Cruelty to Animals (RSPCA) Queensland between January 2012 and December 2013 was undertaken to determine the character and frequency of microchip data problems and their impact on outcome for the animal. Only 28% of dogs and 9% of cats were microchipped, and a substantial proportion (37%) had problems with their data, including being registered to a previous owner or organisation (47%), all phone numbers incorrect/disconnected (29%), and the microchip not registered (14%). A higher proportion of owners could be contacted when the microchip had no problems, compared to those with problems (dogs, 93% vs. 70%; cats, 75% vs. 41%). The proportion of animals reclaimed declined significantly between microchipped animals with no data problems, microchipped animals with data problems and non-microchipped animals—87%, 69%, and 37%, respectively, for dogs and 61%, 33%, and 5%, respectively, for cats. Strategies are needed to increase the accuracy of

  5. Feline immunodeficiency virus testing in stray, feral, and client-owned cats of Ottawa

    OpenAIRE

    Little, Susan E.

    2005-01-01

    Feline immunodeficiency virus (FIV) seroprevalence is evaluated in 3 groups of cats. Seventy-four unowned urban strays were tested, as well as 20 cats from a small feral cat colony, and 152 client-owned cats. Of the 246 cats tested, 161 (65%) were male and 85 (35%) were female. Seroprevalence for FIV was 23% in the urban strays, 5% in the feral cat colony, and 5.9% in the client-owned cats. Ten cats (4%) were also positive for Feline leukemia virus (FeLV) antigen, including 2 cats coinfected ...

  6. Stray current vs anodic polarization in reinforced mortar: a comparative study on steel corrosion behaviour in both regimes

    NARCIS (Netherlands)

    Chen, Zhipei; Koleva, D.A.; van Breugel, K.

    2015-01-01

    Stray current arising from direct current electrified traction systems and then circulat-ing in reinforced concrete structures may initiate corrosion or even accelerate existing corrosion processes on embedded reinforcement. Therefore, stray-current induced corrosion of nearby reinforced concrete

  7. Residual stress characterization of steel TIG welds by neutron diffraction and by residual magnetic stray field mappings

    Energy Technology Data Exchange (ETDEWEB)

    Stegemann, Robert, E-mail: Robert.Stegemann@bam.de [Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, 12200 Berlin (Germany); Cabeza, Sandra; Lyamkin, Viktor; Bruno, Giovanni; Pittner, Andreas [Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, 12200 Berlin (Germany); Wimpory, Robert; Boin, Mirko [HZB Helmholtz-Zentrum Berlin, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Kreutzbruck, Marc [Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, 12200 Berlin (Germany); IKT, University of Stuttgart, Pfaffenwaldring 32, 70569 Stuttgart (Germany)

    2017-03-15

    The residual stress distribution of tungsten inert gas welded S235JRC+C plates was determined by means of neutron diffraction (ND). Large longitudinal residual stresses with maxima around 600 MPa were found. With these results as reference, the evaluation of residual stress with high spatial resolution GMR (giant magneto resistance) sensors was discussed. The experiments performed indicate a correlation between changes in residual stresses (ND) and the normal component of local residual magnetic stray fields (GMR). Spatial variations in the magnetic field strength perpendicular to the welds are in the order of the magnetic field of the earth. - Highlights: • Comparison of magnetic microstructure with neutron diffraction stress analysis. • High spatial resolution magnetic stray field images of hypereutectoid TIG welds. • Spatial variations of the stray fields are below the magnetic field of the earth. • GMR spin valve gradiometer arrays adapted for the evaluation of magnetic microstructures. • Magnetic stray fields are closely linked to microstructure of the material.

  8. Enhanced Measurements of Chromophoric Dissolved Organic Matter (CDOM) for Water Quality Analysis using a New Simultaneous Absorbance and Fluorescence Instrument

    Science.gov (United States)

    Gilmore, A. M.

    2009-12-01

    Water quality, with respect to suspended particles and dissolved organic and inorganic compounds, is now recognized as one of the top global environmental concerns. Contemporary research indicates fluorescence spectral analyses coupled with UV-VIS absorbance assays have the potential, especially when combined and coordinated, to facilitate rapid, robust quantification of a wide range of compounds, including interactions among them. Fluorescence excitation-emission matrices (EEMs) collected over the UV-VIS region provide a wealth of information on chromophoric dissolved organic matter (CDOM). CDOM includes humic and fulvic acid, chlorophyll, petroleum, protein, amino acid, quinone, fertilizer, pesticide, sewage and numerous other compound classes. Analysis of the EEMs using conventional and multivariate techniques, including primarily parallel factor analysis (PARAFAC), provides information about many types of CDOM relevant to carbon cycling and pollution of fresh, marine and drinking water sources. Of critical concern also are the CDOM interactions with, and optical activities of, dissolved inorganic compounds. Many of the inorganic compounds and oxygen demand parameters can be analyzed with a wide range of UV-VIS absorbance assays. The instrument is designed and optimized for high UV throughput and low stray light performance. The sampling optics are optimized for both fluorescence and absorbance detection with the same sample. Both EEM and absorbance measurements implement NIST traceable instrument correction and calibration routines. The fluorescence detection utilizes a high dynamic range CCD coupled to a high-resolution spectrograph while absorbance utilizes diode based detection with a high dynamic range and extremely low-stray light specifications. The CDOM analysis is facilitated by a transfer of the data and model information with the PARAFAC routine. The EEM analysis software package facilitates coordinated correction of and correlation with the

  9. Adaption of an array spectroradiometer for total ozone column retrieval using direct solar irradiance measurements in the UV spectral range

    Science.gov (United States)

    Zuber, Ralf; Sperfeld, Peter; Riechelmann, Stefan; Nevas, Saulius; Sildoja, Meelis; Seckmeyer, Gunther

    2018-04-01

    A compact array spectroradiometer that enables precise and robust measurements of solar UV spectral direct irradiance is presented. We show that this instrument can retrieve total ozone column (TOC) accurately. The internal stray light, which is often the limiting factor for measurements in the UV spectral range and increases the uncertainty for TOC analysis, is physically reduced so that no other stray-light reduction methods, such as mathematical corrections, are necessary. The instrument has been extensively characterised at the Physikalisch-Technische Bundesanstalt (PTB) in Germany. During an international total ozone measurement intercomparison at the Izaña Atmospheric Observatory in Tenerife, the high-quality applicability of the instrument was verified with measurements of the direct solar irradiance and subsequent TOC evaluations based on the spectral data measured between 12 and 30 September 2016. The results showed deviations of the TOC of less than 1.5 % from most other instruments in most situations and not exceeding 3 % from established TOC measurement systems such as Dobson or Brewer.

  10. Study of Intestinal Helminthes of Stray Dogs and Thir Public Heath Importance in Hamadan City

    Directory of Open Access Journals (Sweden)

    Kh. Rahmati

    2016-11-01

    Full Text Available Introduction: Intestinal helminthesof dogs are a serious threat to human health and may cause dangerous diseases such as: hydatidosis and visceral larva migrans, that which cause severe complications in human. Th aim of this study was to determine the prevalenceof intestinal helminthes of stray dogs in Hamadan city, Iran.. Methods: A total of 103 stray dogswere shot in the inner and around of the city in year 2015. Following necropsy, the intestines' contents of dogs were examined for helminthes macroscopically. Thn, the collected worms, aftr washing with saline,were counted and identifid according to being Nematode, Cestodeor Acantcephala. Thn, collected Nematodes were put in glass containers containing 70% ethanol-glycerine and Cestodes aftr processing on slides were put in the 10% formalin. To identify the species of helminthes, the Cestodes were stained using carmine acid and Nematodes were cleared in lacto-phenol. Results: Result indicated that, 74(71.8%stray dogs were infected at least by one species of intestinal helminthes. Th species of parasites were as follows: Echinococcus granulosus 37.9%, Dipylidium caninum 51.5%, Toxocara canis 19.4%, Taenia hydatigena 24.3%, T. multiceps 2.9%, T. ovis 1.9%, Mesocest oideslineatus 4.9%, and Acantho cephala 5.8%. Thre was no association between insex, season and region with prevalence of intestinal helminthes (P 0.05 between the prevalence of intestinal helminthes and dogs' age. Conclusions: Ths study indicatesd that,infection rate of helminthes in stray dogs is washigh in Hamadan city. Thse parasites are important in terms of human health and economic aspects. Threfore, it is more essential that public health authoritiesto develop control strategies for stray dogs population.

  11. Gastrointestinal parasites in stray and shelter cats in the municipality of Rio de Janeiro, Brazil

    Directory of Open Access Journals (Sweden)

    Pâmela Figueiredo Pereira

    Full Text Available Abstract The increasingly urban nature of the population has led many people to choose independent pets, such as cats. This situation has also made it possible for these animals to be abandoned, thus increasing the numbers of cats on the streets and in shelters. These animals can act as a source of infection for other hosts. Between 2014 and 2015, the frequency of gastrointestinal parasites in captive and stray cats in the municipality of Rio de Janeiro was analyzed. Ninety-one fecal samples were collected from captive cats and 172 from stray cats. Centrifugal sedimentation and flotation techniques were used. The frequency of parasites among the stray cats was 77.3%, and this was significantly higher than the frequency observed in captive cats (49.5%. Helminths were detected more frequently, and hookworms were the parasites most detected. Toxocara cati, Cystoisospora sp. and Dipylidium caninum were also detected. No statistical difference in the frequency of parasites was observed between the sexes among the captive cats. However, among the stray cats, males (85.5% presented higher positivity than females (71.8%. The high frequency of hookworms, which are the agent for “cutaneous larva migrans” in humans, shows the need to control parasitic infections among the cats studied.

  12. PCR-based molecular characterization of Toxocara spp. using feces of stray cats: a study from Southwest Iran.

    Science.gov (United States)

    Khademvatan, Shahram; Rahim, Fakher; Tavalla, Mahdi; Abdizadeh, Rahman; Hashemitabar, Mahmoud

    2013-01-01

    Feces of stray cat are potential sources of gastrointestinal parasites and play a crucial role in spreading and transmitting parasite eggs, larvae, and oocysts through contamination of soil, food, or water. In this study, we investigated the prevalence of Toxocara spp. infection in stray cats in Ahvaz city, southwest Iran. Eggs of Toxocara spp. in feces of stray cats were detected by the sucrose flotation method, and identification was conducted by polymerase chain reaction (PCR) and DNA sequencing. Of the 140 fecal samples that were randomly collected from public environments during the months of January to May 2012, 45% were found to harbour Toxocara spp. eggs. The highest prevalence of Toxocara spp. eggs was found in the central area of Ahvaz city (28.6%). T. canis eggs were found in 4 (6.34%) of the 63 positive samples. Stray cats are found in parks, playgrounds, and other public places and may be a potential contamination risk. Identification of Toxocara spp. using molecular methods is sufficiently sensitive to detect low levels of parasites and identify the different Toxocara spp. in feces. The relatively high prevalence of Toxocara spp. infection may continue to increase due to lack of effective environmental hygiene control in Iran. Consequently, there is a need to plan adequate programs to detect, identify, and control this infection as well as stray cats in the region.

  13. PCR-based molecular characterization of Toxocara spp. using feces of stray cats: a study from Southwest Iran.

    Directory of Open Access Journals (Sweden)

    Shahram Khademvatan

    Full Text Available Feces of stray cat are potential sources of gastrointestinal parasites and play a crucial role in spreading and transmitting parasite eggs, larvae, and oocysts through contamination of soil, food, or water. In this study, we investigated the prevalence of Toxocara spp. infection in stray cats in Ahvaz city, southwest Iran. Eggs of Toxocara spp. in feces of stray cats were detected by the sucrose flotation method, and identification was conducted by polymerase chain reaction (PCR and DNA sequencing. Of the 140 fecal samples that were randomly collected from public environments during the months of January to May 2012, 45% were found to harbour Toxocara spp. eggs. The highest prevalence of Toxocara spp. eggs was found in the central area of Ahvaz city (28.6%. T. canis eggs were found in 4 (6.34% of the 63 positive samples. Stray cats are found in parks, playgrounds, and other public places and may be a potential contamination risk. Identification of Toxocara spp. using molecular methods is sufficiently sensitive to detect low levels of parasites and identify the different Toxocara spp. in feces. The relatively high prevalence of Toxocara spp. infection may continue to increase due to lack of effective environmental hygiene control in Iran. Consequently, there is a need to plan adequate programs to detect, identify, and control this infection as well as stray cats in the region.

  14. A review on stray current-induced steel corrosion in infrastructure

    NARCIS (Netherlands)

    Chen, Zhipei; Koleva, D.A.; van Breugel, K.

    2017-01-01

    Metallic corrosion can cause substantial damage at various levels and in almost all types of infrastructure. For metallic corrosion to occur, a certain external environment and the presence of corrodents are the prerequisites. Stray current-induced corrosion, however, is a rather underestimated

  15. Intercomparison of radiation protection devices in a high-energy stray neutron field. Part III: Instrument response

    International Nuclear Information System (INIS)

    Silari, M.; Agosteo, S.; Beck, P.; Bedogni, R.; Cale, E.; Caresana, M.; Domingo, C.; Donadille, L.; Dubourg, N.; Esposito, A.; Fehrenbacher, G.; Fernandez, F.; Ferrarini, M.; Fiechtner, A.; Fuchs, A.; Garcia, M.J.; Golnik, N.; Gutermuth, F.; Khurana, S.; Klages, Th.

    2009-01-01

    The European Commission has funded within its 6th Framework Programme a three-year project (2005-2007) called CONRAD, COordinated Network for RAdiation Dosimetry. The organizational framework for this project was provided by the European radiation Dosimetry Group EURADOS. Work Package 6 of CONRAD dealt with 'complex mixed radiation fields at workplaces' and in this context it organised a benchmark exercise, which included both measurements and calculations, in a stray radiation field at a high-energy particle accelerator at GSI, Germany. The aim was to intercompare the response of several types of active detectors and passive dosemeters in a well-characterised workplace field. The Monte Carlo simulations of the radiation field and the experimental determination of the neutron spectra with various Bonner Sphere Spectrometers are discussed in Rollet et al. (2008) and in Wiegel et al. (2008). This paper focuses on the intercomparison of the response of the dosemeters in terms of ambient dose equivalent. The paper describes in detail the detectors employed in the experiment, followed by a discussion of the results. A comparison is also made with the H*(10) values predicted by the Monte Carlo simulations and those measured by the BSS systems.

  16. Experimental Study on the Influence of AC Stray Current on the Cathodic Protection of Buried Pipe

    Directory of Open Access Journals (Sweden)

    Qingmiao Ding

    2016-01-01

    Full Text Available The size of the damaged area of the coating and its position on the pipeline impacted the cathodic protection potential, and there was a damaged area of the greatest impact value. When damaged area was 300 mm2, the IR drop was the largest, and this situation could easily lead to inadequate protection; when the parallel spacing between pipeline and interference source was unchanged, the measured value curves of cathodic protection potential presented “U” shaped trend with the increasing stray current interference intensity. Under certain parallel spacing between pipeline and interference source, high alternating stray current intensity would cause serious negative offsets, so that the overprotection of the pipeline occurred, and make the coating crack; there was a parallel threshold length. When less than the threshold, the pipe-ground potential increases rapidly with the parallel length increasing. In order to judge whether a pipeline was interference by AC stray current and the risk of stray current corrosion, we should make a comprehensive analysis of the cathodic protection energizing potential, the switch-off potential, AC pipe-soil potential, IR drops, and so on.

  17. What's in a name? Perceptions of stray and feral cat welfare and control in Aotearoa, New Zealand.

    Science.gov (United States)

    Farnworth, Mark J; Campbell, Joanna; Adams, Nigel J

    2011-01-01

    New Zealanders (n = 354) rated the acceptability of lethal and nonlethal cat control methods and the importance of conservation and welfare. Lethal control was more acceptable for feral cats than strays; for nonlethal control, the inverse was true. More than concern for the welfare of cats subjected to control, perceived conservation benefits, risk of disease transfer, and companion cat welfare dictated the acceptability of control measures. Similarly, the welfare consideration for groups of cats differed, transitioning from companion (highest) to feral (lowest). Differences in attitudes toward acceptability of control methods were evident. In particular, nonhuman animal professionals ranked lethal control as more acceptable than did nonanimal professionals. Cat caregivers (owners) considered both conservation and welfare issues of greater importance than did nonowners. Owners ranked the acceptability of nonlethal control methods higher for stray cats, but not feral, than did nonowners. This research indicates that the use of the terms stray and feral may have significant impact on cats in New Zealand. There is also a greater consideration of conservation values than of welfare in stray and feral cat control.

  18. Molecular detection of blood pathogens and their impacts on levels of packed cell volume in stray dogs from Thailand

    Directory of Open Access Journals (Sweden)

    Supawadee Piratae

    2017-04-01

    Full Text Available Objective: To evaluate the prevalence of blood parasite infection in stray dogs by PCR technique and the association between levels of packed cell volume (PCV and blood parasitic infection in stray dogs. Methods: A total of 65 blood samples were collected from stray dogs in animal quarantine station from Mahasarakham, Thailand to evaluate the levels of PCV before molecular screening for tick-borne pathogens infection. Results: Stray dogs were positive with one or more pathogens in 44 (67.69% out of 65 blood samples. Ehrlichia canis [43.1%, 95% confidence interval (CI: 38.1–48.1] was the most common blood pathogen found infecting in stray dogs in Mahasarakham Province, followed by Anaplasma platys (29.2%, 95% CI: 24.2–34.2, Hepatozoon canis (12.3%, 95% CI: 7.3–17.3 and Babesia canis vogeli (6.2%, 95% CI: 1.2–11.2, respectively. Moreover, co-infections with two pathogens were identified in 11 (16.9% of dogs examined and two (2.9% dogs were coinfections with three pathogens. Statistically significant relationship between the PCV levels and Ehrlichia canis infection was found (P < 0.05. Conclusions: This study indicated that blood pathogens are spreading in stray dogs and they are potentially high risk of agent transmission to human via exposure with tick vectors. It was also the first report of Anaplasma platys infection in dogs in north-eastern part of Thailand.

  19. Detection of Helminth Eggs and Identification of Hookworm Species in Stray Cats, Dogs and Soil from Klang Valley, Malaysia.

    Science.gov (United States)

    Tun, Sandee; Ithoi, Init; Mahmud, Rohela; Samsudin, Nur Izyan; Kek Heng, Chua; Ling, Lau Yee

    2015-01-01

    The present study was conducted to determine the prevalence of helminth eggs excreted in the faeces of stray cats, dogs and in soil samples. A total of 505 fresh samples of faeces (from 227 dogs and 152 cats) and soil were collected. The egg stage was detected via microscopy after the application of formalin-ether concentration technique. Genomic DNA was extracted from the samples containing hookworm eggs and used for further identification to the species level using real-time polymerase chain reaction coupled with high resolution melting analysis. Microscopic observation showed that the overall prevalence of helminth eggs among stray cats and dogs was 75.7% (95% CI = 71.2%-79.9%), in which 87.7% of dogs and 57.9% of cats were infected with at least one parasite genus. Five genera of heliminth eggs were detected in the faecal samples, including hookworms (46.4%), Toxocara (11.1%), Trichuris (8.4%), Spirometra (7.4%) and Ascaris (2.4%). The prevalence of helminth infections among stray dogs was significantly higher than that among stray cats (p dog hookworm, Ancylostoma caninum, was also detected among cats, which is the first such occurrence reported in Malaysia till date. This finding indicated that there was a cross-infection of A. caninum between stray cats and dogs because of their coexistent within human communities. Taken together, these data suggest the potential role of stray cats and dogs as being the main sources of environmental contamination as well as for human infections.

  20. Counteracting Animal Homelessness and Providing Care for Stray Animals as a Task of a Commune

    OpenAIRE

    Szalewska, Małgorzata

    2017-01-01

    The analysis of Polish binding law acts allows one to assume that, on normative level, the obligation of public administration to provide care for stray animals is deeply embedded. Both the Animal Protection Act, as well as the Act on Maintaining Cleanliness, indicate the tasks of a commune in the scope of providing care for stray animals, catching homeless animals and counteracting their homelessness. Simultaneously, the analysis of jurisdiction, and inquiries as well as considerations emerg...

  1. Stray dog meat consumption and rabies | Wiwanitkit | African Health ...

    African Journals Online (AJOL)

    Stray dog meat consumption and rabies. V Wiwanitkit. Abstract. No Abstract. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · http://dx.doi.org/10.4314/ahs.v14i3.41 · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians ...

  2. Individual monitoring in high-energy stray radiation fields

    International Nuclear Information System (INIS)

    Hoefert, M.; Stevenson, G.R.

    1995-01-01

    Due to the lack of passive or active devices that could be considered as personal dosemeters in high-energy stray fields one can at present only perform individual monitoring around high energy accelerators. Of all detectors currently available it is shown that the NTA film is the most suitable method for individually monitoring the neutron exposure of more than 3000 persons regularly, reliably, and cost effectively like at CERN. (author)

  3. Gearbox Instrumentation for the Investigation of Bearing Axial Cracking

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jonathan A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lambert, Scott R [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-03-27

    Failures in gearbox bearings have been the primary source of reliability issues for wind turbine drivetrains, leading to costly downtime and unplanned maintenance. The most common failure mode is attributed to so-called axial cracks or white-etching cracks, which primarily affect the intermediate and high-speed-stage bearings. The high-speed-shaft and bearing loads and sliding will be measured with a specially instrumented gearbox installed in a 1.5-megawatt turbine at the National Wind Technology Center in an upcoming test campaign. Additional instrumentation will also measure the tribological environment of these bearings, including bearing temperatures, lubricant temperature and water content, air temperature and humidity, and stray electrical current across the bearings. This paper fully describes the instrumentation package and summarizes initial results.

  4. Optimization method of star tracker orientation for sun-synchronous orbit based on space light distribution.

    Science.gov (United States)

    Wang, Geng; Xing, Fei; Wei, Minsong; Sun, Ting; You, Zheng

    2017-05-20

    Star trackers, optical attitude sensors with high precision, are susceptible to space light from the Sun and the Earth albedo. Until now, research in this field has lacked systematic analysis. In this paper, we propose an installation orientation method for a star tracker onboard sun-synchronous-orbit spacecraft and analyze the space light distribution by transforming the complicated relative motion among the Sun, Earth, and the satellite to the body coordinate system of the satellite. Meanwhile, the boundary-curve equations of the areas exposed to the stray light from the Sun and the Earth albedo were calculated by the coordinate-transformation matrix under different maneuver attitudes, and the installation orientation of the star tracker was optimized based on the boundary equations instead of the traditional iterative simulation method. The simulation and verification experiment indicate that this installation orientation method is effective and precise and can provide a reference for the installation of sun-synchronous orbit star trackers free from the stray light.

  5. Controlling stray electric fields on an atom chip for experiments on Rydberg atoms

    Science.gov (United States)

    Davtyan, D.; Machluf, S.; Soudijn, M. L.; Naber, J. B.; van Druten, N. J.; van Linden van den Heuvell, H. B.; Spreeuw, R. J. C.

    2018-02-01

    Experiments handling Rydberg atoms near surfaces must necessarily deal with the high sensitivity of Rydberg atoms to (stray) electric fields that typically emanate from adsorbates on the surface. We demonstrate a method to modify and reduce the stray electric field by changing the adsorbate distribution. We use one of the Rydberg excitation lasers to locally affect the adsorbed dipole distribution. By adjusting the averaged exposure time we change the strength (with the minimal value less than 0.2 V /cm at 78 μ m from the chip) and even the sign of the perpendicular field component. This technique is a useful tool for experiments handling Rydberg atoms near surfaces, including atom chips.

  6. Feline immunodeficiency virus testing in stray, feral, and client-owned cats of Ottawa.

    Science.gov (United States)

    Little, Susan E

    2005-10-01

    Feline immunodeficiency virus (FIV) seroprevalence is evaluated in 3 groups of cats. Seventy-four unowned urban strays were tested, as well as 20 cats from a small feral cat colony, and 152 client-owned cats. Of the 246 cats tested, 161 (65%) were male and 85 (35%) were female. Seroprevalence for FIV was 23% in the urban strays, 5% in the feral cat colony, and 5.9% in the client-owned cats. Ten cats (4%) were also positive for Feline leukemia virus (FeLV) antigen, including 2 cats coinfected with FeLV and FIV. Seroprevalence for FIV in cats from Ottawa is similar to that found in other nonrandom studies of cats in North America.

  7. Measurement of stray EC radiation on W7-AS

    Science.gov (United States)

    Gandini, F.; Hirsch, M.; Cirant, S.; Erckmann, V.; Granucci, G.; Kasparek, W.; Laqua, H. P.; Muzzini, V.; Nowak, S.; Radau, S.

    2001-10-01

    In the framework of a collaboration between IFP-CNR Milano, IPP Garching/Greifswald and IPF Stuttgart, a set of four millimeterwave probes has been installed in W7-AS stellarator at selected positions of the inner vessel wall. Their purpose is to observe RF stray radiation during operation in presence of strong level of Electron Cyclotron (EC) waves, used for plasma start-up, heating and current drive. The aim of these measurements is to benchmark two complementary theoretical models for the distribution of the stray radiation in the vessel. From these codes, quantitative predictions are expected for the spatial distribution of the RF wall load and the RF-impact on in-vessel components in large future devices such as W7-X and, possibly, ITER. This input is important to optimize the wall armour and select rf-compatible in-vessel materials. We present first measurements from different heating and startup scenarios, with up to 800 kW of injected power at 140 GHz and different launching geometries. An analysis of measurements performed on FTU using a previous version of sniffer probe is also presented.

  8. Measurement of stray EC radiation on W7-AS

    International Nuclear Information System (INIS)

    Gandini, F.; Cirant, S.; Granucci, G.; Muzzini, V.; Nowak, S.; Hirsch, M.; Erckmann, V.; Laqua, H.P.; Radau, S.; Kasparek, W.

    2001-01-01

    In the framework of a collaboration between IFP-CNR Milano, IPP Garching/Greifswald and IPF Stuttgart, a set of four millimeterwave probes has been installed in W7-AS stellarator at selected positions of the inner vessel wall. Their purpose is to observe RF stray radiation during operation in presence of strong level of Electron Cyclotron (EC) waves, used for plasma start-up, heating and current drive. The aim of these measurements is to benchmark two complementary theoretical models for the distribution of the stray radiation in the vessel. From these codes, quantitative predictions are expected for the spatial distribution of the RF wall load and the RF-impact on in-vessel components in large future devices such as W7-X and, possibly, ITER. This input is important to optimize the wall armour and select rf-compatible in-vessel materials. We present first measurements from different heating and startup scenarios, with up to 800 kW of injected power at 140 GHz and different launching geometries. An analysis of measurements performed on FTU using a previous version of sniffer probe is also presented

  9. Prevalence of intestinal helminth parasites in stray dogs in urban ...

    African Journals Online (AJOL)

    A total of 246 faecal samples were collected between October 2015 to February 2016, 154 from stray dogs in Harare and 92 from rural dogs in Arcturas, Goromonzi and Christon Bank. The samples were examined by flotation and sedimentation methods and helminth eggs identified and EPG counted. Of the 246 samples, ...

  10. UV Blocking Glass: Low Cost Filters for Visible Light Photocatalytic Assessment

    OpenAIRE

    Dunnill, Charles W.

    2014-01-01

    A number of commercially available art protection products have been compared and assessed for their suitability as UV blocking filters in the application of “visible light” photocatalytic research. Many groups claiming visible light photocatalytic success employ filters to block out stray UV radiation in order to justify that their photocatalysts are indeed visible light photocatalysts and not UV light photocatalysts. These filters come in varying degrees of ability and price and many author...

  11. MRI-related static magnetic stray fields and postural body sway: a double-blind randomized crossover study.

    Science.gov (United States)

    van Nierop, Lotte E; Slottje, Pauline; Kingma, Herman; Kromhout, Hans

    2013-07-01

    We assessed postural body sway performance after exposure to movement induced time-varying magnetic fields in the static magnetic stray field in front of a 7 Tesla (T) magnetic resonance imaging scanner. Using a double blind randomized crossover design, 30 healthy volunteers performed two balance tasks (i.e., standing with eyes closed and feet in parallel and then in tandem position) after standardized head movements in a sham, low exposure (on average 0.24 T static magnetic stray field and 0.49 T·s(-1) time-varying magnetic field) and high exposure condition (0.37 T and 0.70 T·s(-1)). Personal exposure to static magnetic stray fields and time-varying magnetic fields was measured with a personal dosimeter. Postural body sway was expressed in sway path, area, and velocity. Mixed-effects model regression analysis showed that postural body sway in the parallel task was negatively affected (P < 0.05) by exposure on all three measures. The tandem task revealed the same trend, but did not reach statistical significance. Further studies are needed to investigate the possibility of independent or synergetic effects of static magnetic stray field and time-varying magnetic field exposure. In addition, practical safety implications of these findings, e.g., for surgeons and others working near magnetic resonance imaging scanners need to be investigated. Copyright © 2012 Wiley Periodicals, Inc.

  12. Neutron measurements in the stray field produced by 158 GeV/c lead ion beams

    International Nuclear Information System (INIS)

    Agosteo, S.; Birattari, C.; Foglio Para, A.; Nava, E.; Silari, M.; Ulrici, L.

    1997-01-01

    This paper discusses measurements carried out at CERN in the stray radiation field produced by 158 GeV/c 208 Pb 82+ ions. The purpose was to test and intercompare the response of several detectors, mainly neutron measuring devices, and to determine the neutron spectral fluence as well as the microdosimetric (absorbed dose and dose equivalent) distributions in different locations around the shielding. Both active instruments and passive dosimeters were employed, including different types of Andersson-Braun rem counters, a tissue equivalent proportional counter, a set of superheated drop detectors, a Bonner sphere system and different types of ion chambers. Activation measurements with 12 C plastic scintillators and with 32 S pellets were also performed to assess the neutron yield of high energy lead ions interacting with a thin gold target. The results are compared with previous measurements and with measurements made during proton runs. (author)

  13. Detection of Helminth Eggs and Identification of Hookworm Species in Stray Cats, Dogs and Soil from Klang Valley, Malaysia.

    Directory of Open Access Journals (Sweden)

    Sandee Tun

    Full Text Available The present study was conducted to determine the prevalence of helminth eggs excreted in the faeces of stray cats, dogs and in soil samples. A total of 505 fresh samples of faeces (from 227 dogs and 152 cats and soil were collected. The egg stage was detected via microscopy after the application of formalin-ether concentration technique. Genomic DNA was extracted from the samples containing hookworm eggs and used for further identification to the species level using real-time polymerase chain reaction coupled with high resolution melting analysis. Microscopic observation showed that the overall prevalence of helminth eggs among stray cats and dogs was 75.7% (95% CI = 71.2%-79.9%, in which 87.7% of dogs and 57.9% of cats were infected with at least one parasite genus. Five genera of heliminth eggs were detected in the faecal samples, including hookworms (46.4%, Toxocara (11.1%, Trichuris (8.4%, Spirometra (7.4% and Ascaris (2.4%. The prevalence of helminth infections among stray dogs was significantly higher than that among stray cats (p < 0.001. Only three genera of helminths were detected in soil samples with the prevalence of 23% (95% CI = 15.1%-31%, consisting of hookworms (16.6%, Ascaris (4% and Toxocara (2.4%. The molecular identification of hookworm species revealed that Ancylostoma ceylanicum was dominant in both faecal and soil samples. The dog hookworm, Ancylostoma caninum, was also detected among cats, which is the first such occurrence reported in Malaysia till date. This finding indicated that there was a cross-infection of A. caninum between stray cats and dogs because of their coexistent within human communities. Taken together, these data suggest the potential role of stray cats and dogs as being the main sources of environmental contamination as well as for human infections.

  14. PENGARUH PEMBELAJARAN KOOPERATIF TWO STAY TWO STRAY BERPENDEKAT AN SETS TERHADAP HASIL BELAJAR KIMIA SISWA SMA NEGERI 1 COMAL

    Directory of Open Access Journals (Sweden)

    A. T. Setiawan

    2016-07-01

    Full Text Available Penelitian ini bertujuan untuk mengetahui pengaruh pembelajaran kooperatif two stay two stray berpendekatan SETS terhadap hasil belajar siswa. Desain eksperimen yang digunakan dalam penelitian ini adalah quasi experimental design. Hasil penelitian menunjukkan bahwa pembelajaran kooperatif two stay two stray berpendekatan SETS berpengaruh signitikan terhadap hasil belajar pada materi pokok teori asam basa dengan kontribusi koefisien determinasi sebesar 25%. Selain itu, pembelajaran juga mencapai ketuntasan belajar klasikal sebesar 37 dari 43 siswa, sehingga pembelajaran tersebut termasuk efektif.This study aimed to determine the effect of two stay two stray cooperative learning with SETS approach on student learning outcomes. Experimental design used in this study is a quasi experimental design. The results showed that two stay two stray cooperative learning with SETS approach have a significant effect on learning outcomes in acid-base theory of the subject matter with the contribution of the determination coefficient of 25%. In addition, the study also achieved mastery learning classical by 37 of the 43 students, so that it includes effective learning.

  15. Data from an instrumented navigational light tower off the Savanah River estuary

    International Nuclear Information System (INIS)

    Hayes, D.W.; Dicks, A.S.; Blanton, J.O.

    1978-01-01

    An oceanographic and meteorological instrumentation system operating on the Savannah Navigational Light Tower is providing synoptic information on ocean temperatures, currents, tides, and meteorological conditions. The Savannah Navigational Light Tower, an unmanned U.S. Coast Guard tower, is located about nine miles off Savannah Beach, Georgia, in about 16 m of water. The tower is currently instrumented to measure and record water temperatures from six depths, water velocities at two depts, tides, air temperature, barometric pressure, and wind speed and velocity at two heights. The outputs are currently being recorded every 10 minutes. These data aid in the interpretation of the processes governing pollutant transport in the Savannah River marine region and support other DOE funded programs in the southeastern United States. This past year, computer programs were written and are being tested for processing the raw data from the tower and for performing correlative analysis of the data

  16. Gastrointestinal Helminths and Ectoparasites in the Stray Cats (Felidae: Felis catus) of Ahar Municipality, Northwestern Iran

    Science.gov (United States)

    YAKHCHALI, Mohammad; HAJIPOUR, Nasser; MALEKZADEH-VIAYEH, Reza; ESMAEILNEJAD, Bijan; NEMATI-HARAVANI, Taher; FATHOLLAHZADEH, Mohammad; JAFARI, Rasool

    2017-01-01

    Background: The stray cats are considered as the sources of emerging humans and domestic livestock pathogens and the zoonoses of public health importance. The present study was aimed to elucidate intestinal helminth infections and infestation with ectoparasites of the stray cats of Ahar City, northwestern Iran. Methods: Totally, 51 stray cats were randomly trapped from different parts of the city between Mar and Nov 2013. The cats were assessed for ectoparasites by hair brushing, skin scraping, acetate tape preparation and othic swabs. They were euthanized and inspected for helminths infection. Results: Overall prevalence of helminths and flea were 44/51 (86.3%) and 31/51 (60.78%), respectively. The infection rates were significantly different among different age groups (PDipylidium caninum (29.41%), T. hydatigena (19.6%)) were identified. The predominant infectious helminths in all the infected cats were T. cati (86.3% with egg per gram of feces 27.75±9). Of the 270 collected fleas, two species of Ctenocephalides felis (80%) and C. canis (20%) were notably frequent in the cats aged 2-3-year-old. The average number of fleas per each infected cat was recorded as 5.29, with no incidence of cross-infection. Conclusion: The results indicated the high rate of helminths infections and flea infestation in the urban stray cats of which Toxocara cati and Ctenocephalides felis may play important roles as zoonotic agents in the region. PMID:28761492

  17. Gastrointestinal helminth parasites of pet and stray dogs as a potential risk for human health in Bahir Dar town, north-western Ethiopia

    Directory of Open Access Journals (Sweden)

    Tadiwos Abere

    Full Text Available Aim: A cross-sectional study was carried out from November 2011 to April 2012 to determine the prevalence and species of gastrointestinal (GI helminth parasites in pet and stray dogs as a potential risk for human health in Bahir Dar town, northwestern Ethiopia. Materials and Methods: A total of 384 and 46 faecal samples were collected from pet and stray dogs, respectively and xamined by using standard coprologic techniques. Results: The overall prevalence of GI helminth infection in pet and stray dogs was 75.26 and 84.78%, respectively. The detected parasites with their frequencies in pet dogs were Ancylostoma caninum (78.89%, Toxocara canis (39.79%, Dipylidium caninum (29.75%, Strongyloides stercoralis (29.06%, Taeniidae (23.87% and Trichuris vulpis (7.95%. Stray dogs were found more likely to be polyparasitized and presented higher prevalence of A. caninum, T. canis, S. stercoralis, Trichuris vulpis and Taeniidae (P < 0.05 than domiciled ones. Diphyllobothrium latum was detected only in 10.25% of stray dogs. Toxocara canis and A. caninum (P < 0.05 were detected more frequently in dogs with less than 6 months of age (P <0.05 than old age dogs. The sex or breed groups didn't significantly affect the prevalence of parasites. A significant variation was recorded (P < 0.05 between different feeding systems where higher prevalence was observed in uncontrolled feeding group (82.18% compared to controlled feeding (32.08%. Conclusion: Different gastrointestinal parasites in pet and stray dogs were identified in the study area that can potentially infect humans and cause serious public-health problems. Thus, concerted efforts should therefore be made to educate dog owners to embrace modern dog disease control programs and measures have to be taken on stray dogs. [Vet World 2013; 6(7.000: 388-392

  18. THE SOCIETY’S PERCEPTION OF THE LIFE QUALITY AND POPULATION CONTROL OF STRAY DOGS

    Directory of Open Access Journals (Sweden)

    Flavio Fernando Batista Moutinho

    2015-10-01

    Full Text Available In most Brazilian municipalities there is an overpopulation of stray dogs, which causes problems to the urban order, the environment and the public health, in addition to mistreatment to these dogs. In such context we foresee the need of developing actions targeting the population control of these animals. This essay aims at knowing the perception of social actors, such as managers of entities responsible for control actions, managers of NGOs working with animal protection and population in general with respect to the life quality and population control of stray dogs. Questionnaires were used on samples of individuals of these three groups and the data thereof were analyzed with descriptive statistics techniques and frequency comparison. The results allowed us to conclude that the society’s perception of population control and life quality of these animals bear important differences under the viewpoint of the three evaluated groups; however, they also bear significant similarities, especially with respect to the perception of the responsibility for the development of population control actions, the acceptance of using public funds intended to public health in control actions, the classification of such population density as large and the poor life quality of these animals. population control, social perception, stray dog.,

  19. Effect of stray current on corrosion behavior of reinforcing steel: importance of cell geometry and orientation with respect to the electrical field

    NARCIS (Netherlands)

    Chen, Zhipei; Koleva, D.A.

    2016-01-01

    Stray current circulating in reinforced concrete structures may initiate corrosion or accelerate existing corrosion processes on embedded reinforcement. In some cases, the range of dangerous or unwanted interactions of stray currents under favorable conditions (environment), is much broader than is

  20. Heterodyne quasi-elastic light-scattering instrument for biomedical diagnostics.

    Science.gov (United States)

    Lebedev, A D; Ivanova, M A; Lomakin, A V; Noskin, V A

    1997-10-20

    The heterodyne technique has a number of advantages over the homodyne technique when an accurate characterization of particle-size distribution (PSD) of heterogeneous systems is required. However, there are problems related to acoustic vibrations that make it difficult to take advantage of the heterodyne technique. An instrument developed for quasi-elastic light scattering (QELS) that uses the optical heterodyning principle is described. Vibration-related problems are considerably reduced because of the incorporation of all optical elements into one solid optical block. A real-time correlation analysis of the photocurrent fluctuations is performed by a PC-embedded analog-to-digital converter card with a digital signal processor. Investigation of the PSD in biological fluids for medical diagnostics is presented as a typical application. A diagnostic analysis of the PSD requires a simultaneous processing of a huge number of QELS data. An original statistical algorithm to accomplish this analysis has been developed. Technical specifications of instrumentation for heterodyne QELS measurement are discussed.

  1. IMPLEMENTASI MODEL PEMBELAJARAN TWO STAY TWO STRAY DALAM PEMBELAJARAN BERBASIS KEMAMPUAN BERPIKIR KRITIS KELAS V SD

    Directory of Open Access Journals (Sweden)

    M. Yusuf Setia Wardana

    2017-04-01

    Full Text Available Benefits of mathematics are to equip students with the ability to think logically, analytical, systematically, critically, and creatively, as well as the ability to cooperate. Based on observations in elementary school, there are 40% of students have not reached KKM and students have lack of critical abilities to understand math problems, and they have low activity of the study. One of models that can be applied is Two Stay Two Stray. The study used True Experimental Design with Posttest-Only Control Design. The population in this study was all fifth grade students of SD Negeri Semarang Rejosari 03. Data of critical thinking skills of the students in average on test of critical thinking skills mastery was 3.31 ≥ 2.67, it can be said to have a complete description. The conclusion is a model of Two Stay Two Stray being effective for critical thinking skills and mathematics learning outcomes of fifth grade students in SD Negeri Rejosari 03 Semarang. Keywords: two stay two stray model, critical thinking ability.

  2. Symptoms and Cognitive Effects of Exposure to Magnetic Stray Fields of MRI Scanners

    NARCIS (Netherlands)

    Vocht, Frank Gérard de

    2006-01-01

    People working routinely with magnetic resonance imaging (MRI) systems report a number of symptoms related to their presence in the inhomogeneous static magnetic fields (the stray field) surrounding these scanners. Experienced symptoms and neurobehavioral performance among engineers manufacturing

  3. Stray cats are more frequently infected with zoonotic protists than pet cats.

    Science.gov (United States)

    Kvac, Martin; Hofmannova, Lada; Ortega, Ynes; Holubova, Nikola; Horcickova, Michaela; Kicia, Marta; Hlaskova, Lenka; Kvetonova, Dana; Sak, Bohumil; McEvoy, John

    2017-12-06

    Faecal samples were collected from cats kept as pets (n = 120) and stray cats (n = 135) in Central Europe (Czech Republic, Poland and Slovakia) and screened for the presence of Cryptosporidium spp., Giardia intestinalis (Kunstler, 1882), Encephalitozoon spp. and Enterocytozoon bieneusi Desportes, Le Charpentier, Galian, Bernard, Cochand-Priollet, Lavergne, Ravisse et Modigliani, 1985 by PCR analysis of the small-subunit of rRNA (Cryptosporidium spp. and G. intestinalis) and ITS (microsporidia) genes. Sequence analysis of targeted genes revealed the presence of C. felis Iseki, 1979, G. intestinalis assemblage F, E. cuniculi Levaditi, Nicolau et Schoen, 1923 genotype II, and E. bieneusi genotype D. There was no correlation between the occurrence of detected parasites and sex, presence of diarrhoea or drug treatment (drug containing pyrantel and praziquantel). Compared to pet cats (7%), stray cats (30%) were statistically more frequently infected with protist parasites and overall may present a greater risk to human health.

  4. Stray Cats Gastrointestinal Parasites and its Association With Public Health in Ahvaz City, South Western of Iran

    Science.gov (United States)

    Khademvatan, Shahram; Abdizadeh, Rahman; Rahim, Fakher; Hashemitabar, Mahamoud; Ghasemi, Mohammad; Tavalla, Mahdi

    2014-01-01

    Background: Cats are the hosts for some zoonotic parasites such as Toxoplasma gondii and Toxocara spp. which are important in medicine and veterinary. Studies on the prevalence of intestinal parasites of cats have received little attention in south west of Iran. Objectives: The current study aimed to investigate the prevalence of parasites in stray cats in Ahvaz. Materials and Methods: Random sampling was carried out from January to May 2012. One hundred and forty fecal samples from stray cats were examined using sucrose flotation method. Results: Gastrointestinal parasites were found in 121 of the 140 (86.4%) examined samples. The parasites detected in stray cats were Toxocara spp. (45%, 63/140), Isospora spp. (21.4%, 30/140), nematode larvae (21.4%, 30/140), Taenia spp. (18.6%, 26/140), Sarcocystis spp. (17.1%, 24/140), Eimeria spp. (15%, 21/140), Blastocystis spp. (14.3%, 20/140), Giardia spp, (10.7%, 15/140), Physaloptera spp. (7.1%, 10/140), and amoeba cyst (5.7%, 8/140) respectively. The prevalence of infection by Joyexiella spp. and hook worms (4.3%, 6/140), for example, Dipylidium caninum (2.9%, 4/140) was similar; and the prevalence of infection by T. gondii and Dicrocoelium dendriticum was similar (1.4%, 2/140). Conclusions: Since the prevalence of zoonotic gastrointestinal parasites such as Toxocara spp. in stray cats is high, there is a need to plan adequate programs to control these zoonotic parasites. PMID:25485047

  5. Stray dogs and cats as potential sources of soil contamination with zoonotic parasites

    Directory of Open Access Journals (Sweden)

    Katarzyna Szwabe

    2017-03-01

    Cat faeces represent a more important potential source of environmental contamination with zoonotic parasites than dog faeces. Among the detected parasites of stray dogs and cats, Toxocara present an important zoonotic risk for the local human population, especially children.

  6. Evaluation of stray radiofrequency radiation emitted by electrosurgical devices

    International Nuclear Information System (INIS)

    De Marco, M; Maggi, S

    2006-01-01

    Electrosurgery refers to the passage of a high-frequency, high-voltage electrical current through the body to achieve the desired surgical effects. At the same time, these procedures are accompanied by a general increase of the electromagnetic field in an operating room that may expose both patients and personnel to relatively high levels of radiofrequency radiation. In the first part of this study, we have taken into account the radiation emitted by different monopolar electrosurgical devices, evaluating the electromagnetic field strength delivered by an electrosurgical handle and straying from units and other electrosurgical accessories. As a summary, in the worst case a surgeon's hands are exposed to a continuous and pulsed RF wave whose magnetic field strength is 0.75 A m -1 (E-field 400 V m -1 ). Occasionally stray radiation may exceed ICNIRP's occupational exposure guidelines, especially close to the patient return plate. In the second part of this paper, we have analysed areas of particular concern to prevent electromagnetic interference with some life-support devices (ventilators and electrocardiographic devices), which have failed to operate correctly. Most clinically relevant interference occurred when an electrosurgery device was used within 0.3 m of medical equipment. In the appendix, we suggest some practical recommendations intended to minimize the potential for electromagnetic hazards due to therapeutic application of RF energy

  7. Gastrointestinal and ectoparasites from urban stray dogs in Fortaleza (Brazil): high infection risk for humans?

    Science.gov (United States)

    Klimpel, Sven; Heukelbach, Jörg; Pothmann, David; Rückert, Sonja

    2010-08-01

    Dogs are important definite or reservoir hosts for zoonotic parasites. However, only few studies on the prevalence of intestinal parasites in urban areas in Brazil are available. We performed a comprehensive study on parasites of stray dogs in a Brazilian metropolitan area. We included 46 stray dogs caught in the urban areas of Fortaleza (northeast Brazil). After euthanization, dogs were autopsied. Ectoparasites were collected, and the intestinal content of dogs were examined for the presence of parasites. Faecal samples were collected and analysed using merthiolate iodine formaldehyde concentration method. A total of nine different parasite species were found, including five endoparasite (one protozoan, one cestode and three nematode species) and four ectoparasite species (two flea, one louse and one tick species). In the intestinal content, 3,162 specimens of four helminth species were found: Ancylostoma caninum (prevalence, 95.7%), Dipylidium caninum (45.7%), Toxocara canis (8.7%) and Trichuris vulpis (4.3%). A total of 394 ectoparasite specimens were identified, including Rhipicephalus sanguineus (prevalence, 100.0%), Heterodoxus spiniger (67.4%), Ctenocephalides canis (39.1%) and Ctenocephalides felis (17.4%). In the faeces, intestinal parasites were detected in 38 stray dogs (82.6%), including oocysts of Giardia sp. (2.2%) and eggs of the nematode A. caninum (82.6%). Neither eggs nor larval stages of D. caninum, T. canis or T. vulpis were detected in dog faeces. Sensitivity of faecal examination for A. caninum was 86.4% (95% confidence interval, 72.0-94.3) but zero percentage for the other intestinal helminth species. Our data show that stray dogs in northeast Brazil carry a multitude of zoonotic ecto- and endoparasites, posing a considerable risk for humans. With the exception of A. caninum, sensitivity of faecal examination was negligible.

  8. Molecular detection of Ehrlichia canis, Hepatozoon canis and Babesia canis vogeli in stray dogs in Mahasarakham province, Thailand.

    Science.gov (United States)

    Piratae, Supawadee; Pimpjong, Kiattisak; Vaisusuk, Kotchaphon; Chatan, Wasupon

    2015-01-01

    Canine tick borne diseases showing distribution worldwide have caused morbidity and mortality in dogs. This study observed the mainly tick borne pathogens described for dogs in Thailand, Ehrlichia canis, Hepatozoon canis and Babesia canis vogeli. From May to July 2014, blood samples were collected from 79 stray dogs from 7 districts of Mahasarakham province to molecular surveyed for 16s rRNA gene of E. canis and 18s rRNA gene of H. canis and B. canis vogeli. Twenty eight (35.44%) of stray dogs showed the infection with tick borne pathogens. The prevalence of E. canis infection was the highest with 21.5% (17/79). DNA of H. canis and B. canis vogeli were detected at the prevalence of 10.1% (8/79) and 6.3% (5/79), respectively. Co-infection between E. canis and B. canis vogeli were identified in 2 (2.5%) dogs. The results indicated that a wide range of tick borne pathogens are circulation in the canine population in Mahasarakham province. This study is the first report on prevalence of E. canis, H. canis and B. canis vogeli in stray dogs in Mahasarakham, a province in northern part of Thailand. This data providing is important to understand the prevalence of E. canis, H. canis and B. canis vogeli infection in stray dogs in this region, which will assist in the management of these blood parasite.

  9. An estimate of the radiation-induced cancer risk from the whole-body stray radiation exposure in neutron radiotherapy

    International Nuclear Information System (INIS)

    Geraci, J.P.; Jackson, K.L.; Mariano, M.S.

    1982-01-01

    1980 BEIR III risk factors have been used to estimate the secondary cancer risks from the whole-body stray radiation exposures occurring in neutron radiotherapy. Risks were calculated using linear, linear-quadratic and quadratic dose-response models for the gamma component of the stray radiation. The linear dose-response model was used to calculate risk for the neutron component of the stray radiation. These estimates take into consideration for the first time the age and sex distribution of patients undergoing neutron therapy. Changes in risk as a function of the RBE (10-100) assigned to the stray neutron radiation component have also been assessed. Excess risks in neutron-treated patients have been compared with excess risks for photon-treated patients and with the expected incidence of cancer in a normal population having the same age and sex distribution. Results indicate that it will be necessary to tolerate a higher incidence of secondary cancers in patients undergoing fast neutron therapy than is the case with conventional photon therapy. For neutron RBEs of less than 50 the increased risk is only a fraction of the normal expected incidence of cancer in this population. Comparison of the radiation-induced risk with reported normal tissue complication rates in the treatment volume indicates that the excess cancer risk is substantially lower than the risk from other late normal tissue effects. (author)

  10. Shielding of the NBI boxes against W7-X magnetic stray fields

    Energy Technology Data Exchange (ETDEWEB)

    Kick, Manfred [Max-Planck-Institut fuer Plasmaphysik, Boltzmannstr. 2, D-85748 Garching (Germany)], E-mail: Kick@arcor.de; Sielanko, Juliusz [Maria Curie Sklodowska University, Pl. M. C. Sklodowskie 1, 20-031 Lublin (Poland); Heinemann, Bernd; Riedl, Rudolf; Speth, Eckehart; Staebler, Albrecht [Max-Planck-Institut fuer Plasmaphysik, Boltzmannstr. 2, D-85748 Garching (Germany)

    2009-06-15

    Neutral Beam Injection (NBI), besides ECRH, is foreseen as one of the main heating devices at the W7-X stellarator currently under construction at IPP Greifswald, Germany. In a final stage 20 MW of NBI heating power will be installed generated by two NBI boxes of the ASDEX Upgrade (AUG) type. Since magnetic fields generally affect the trajectories of charged particles, essentially all the NBI boxes - including ion sources, acceleration sections, neutralisers and deflection magnets - must be shielded against the stray fields of W7-X. In the magnetic stray fields of W7-X there exist significant radial and toroidal components whereas at tokamaks the vertical components are dominant. The power loads on the ion dump and the protecting structures of the deflecting magnets and the beam lines caused by residual beam ions, therefore, will be strongly different. Thus the shielding concept of AUG cannot simply be taken over, but must be carefully redesigned in order to remain below the critical power limits. New modelling calculations of the magnetic shielding, the ion trajectories and the resulting power loads have been carried out for the 'high iota' and 'low shear' experimental scenarios of W7-X. The fields taken for these calculations are modelled by averaging the calculated W7-X stray fields on the one hand, and by fields generated by two-hypothetical-planar coils perpendicular to the x-y plane, on the other hand. The shielding concept for W7-X mainly consist of iron plates in the outer side regions of the boxes and as little magnetic material as possible inside the boxes.

  11. Strong spectral variation of biomass smoke light absorption and single scattering albedo observed with a novel dual-wavelength photoacoustic instrument

    Science.gov (United States)

    Kristin Lewis; William P. Arnott; Hans Moosmuller; Cyle E. Wold

    2008-01-01

    A dual-wavelength photoacoustic instrument operating at 405 and 870 nm was used during the 2006 Fire Lab at Missoula Experiment to measure light scattering and absorption by smoke from the combustion of a variety of biomass fuels. Simultaneous measurements of aerosol light scattering by reciprocal nephelometry within the instrument's acoustic resonator accompany...

  12. Anti-glare LED lamps with adjustable illumination light field.

    Science.gov (United States)

    Chen, Yung-Sheng; Lin, Chung-Yi; Yeh, Chun-Ming; Kuo, Chie-Tong; Hsu, Chih-Wei; Wang, Hsiang-Chen

    2014-03-10

    We introduce a type of LED light-gauge steel frame lamp with an adjustable illumination light field that does not require a diffusion plate. Base on the Monte Carlo ray tracing method, this lamp has a good glare rating (GR) of 17.5 at 3050 lm. Compared with the traditional LED light-gauge steel frame lamp (without diffusion plate), the new type has low GR. The adjustability of the illumination light field could improve the zebra effect caused by the inadequate illumination light field of the lamp. Meanwhile, we adopt the retinal image analysis to discuss the influence of GR on vision. High GR could reflect stray light on the retinal image, which will reduce vision clarity and hasten the feeling of eye fatigue.

  13. Stray animal populations and public health in the South Mediterranean and the Middle East regions

    Directory of Open Access Journals (Sweden)

    Aristarhos Seimenis

    2014-06-01

    Full Text Available Uncontrolled urban growth in South Mediterranean and the Middle East regions involves city dwellers and stray animals (mainly dogs and cats creating a dense and downgraded environment, in which irregular street garbage collection disposes sufficient food for survival and proliferation of stray animals. Under such conditions serious public health hazards are expected due to the increase of animal bites, the multiplication of insects and rodents vectors of different viral, bacterial, fungal and parasitic agents to which humans are exposed. Traditional national stray animal eradication programs and occasional small animals' humane elimination campaigns are insufficient to avert human and veterinary health risks when not coupled with modern technologies. In such environments, multiple foci of emerging and re‑emerging zoonoses easily spread, i.e. rabies, hydatidosis, leishmaniasis and toxoplasmosis. Upgrading urban and peri-urban situations requires integrated/coordinated management programmes, in which public and animal health services as well as municipalities have a crucial role. Control and upgrading programmes should be flexible and able to adapt to the specific conditions of the given country/region. In this context, intersectoral/interprofessional collaborations and community participation are crucial for any national and regional development strategies. In this respect, a global approach considering both public health and socio-economic problems shows to be extremely adequate and effective.

  14. Problems Associated with the Microchip Data of Stray Dogs and Cats Entering RSPCA Queensland Shelters

    Directory of Open Access Journals (Sweden)

    Emily Lancaster

    2015-05-01

    Full Text Available A lack of published information documenting problems with the microchip data for the reclaiming of stray animals entering Australian shelters limits improvement of the current microchipping system. A retrospective study analysing admission data for stray, adult dogs (n = 7258 and cats (n = 6950 entering the Royal Society for the Prevention of Cruelty to Animals (RSPCA Queensland between January 2012 and December 2013 was undertaken to determine the character and frequency of microchip data problems and their impact on outcome for the animal. Only 28% of dogs and 9% of cats were microchipped, and a substantial proportion (37% had problems with their data, including being registered to a previous owner or organisation (47%, all phone numbers incorrect/disconnected (29%, and the microchip not registered (14%. A higher proportion of owners could be contacted when the microchip had no problems, compared to those with problems (dogs, 93% vs. 70%; cats, 75% vs. 41%. The proportion of animals reclaimed declined significantly between microchipped animals with no data problems, microchipped animals with data problems and non-microchipped animals—87%, 69%, and 37%, respectively, for dogs and 61%, 33%, and 5%, respectively, for cats. Strategies are needed to increase the accuracy of microchip data to facilitate the reclaiming of stray dogs and cats.

  15. Gastrointestinal Helminths and Ectoparasites in the Stray Cats (Felidae: Felis catus of Ahar Municipality, Northwestern Iran

    Directory of Open Access Journals (Sweden)

    Mohammad YAKHCHALI

    2017-06-01

    Full Text Available Background: The stray cats are considered as the sources of emerging humans and domestic livestock pathogens and the zoonoses of public health importance. The present study was aimed to elucidate intestinal helminth infections and infestation with ectoparasites of the stray cats of Ahar City, northwestern Iran.Methods: Totally, 51 stray cats were randomly trapped from different parts of the city between Mar and Nov 2013. The cats were assessed for ectoparasites by hair brushing, skin scraping, acetate tape preparation and othic swabs. They were euthanized and inspected for helminths infection.Results: Overall prevalence of helminths and flea were 44/51 (86.3% and 31/51 (60.78%, respectively. The infection rates were significantly different among different age groups (P<0.05. Of the 282 isolated helminths, three species of nematodes (Toxocara cati (86.3%, T. leonina (11.77%, Ancylostoma tubaeforme (5.9% and four species of cestodes (Taenia taeniaeformis (64.7%, Mesocestoides lineatus (49.02%, Dipylidium caninum (29.41%, T. hydatigena (19.6% were identified. The predominant infectious helminths in all the infected cats were T. cati (86.3% with egg per gram of feces 27.75±9. Of the 270 collected fleas, two species of Ctenocephalides felis (80% and C. canis (20% were notably frequent in the cats aged 2-3-year-old. The average number of fleas per each infected cat was recorded as 5.29, with no incidence of cross-infection.Conclusion: The results indicated the high rate of helminths infections and flea infestation in the urban stray cats of which Toxocara cati and Ctenocephalides felis may play important roles as zoonotic agents in the region.

  16. Monitoring DC stray current interference of steel sheet pile structures in railway environment

    NARCIS (Netherlands)

    Peelen, W.H.A.; Neeft, E.A.C.; Leegwater, G.; Kanten-Roos, W. van; Courage, W.M.G.

    2011-01-01

    Steel structures near DC powered railways are expected to be affected by stray current interference. This causes accelerated corrosion rates. Therefore steel is often not used as a building material in these cases, although certain advantages over the alternative material concrete exist. These

  17. Intercomparison of the LASCO-C2, SECCHI-COR1, SECCHI-COR2, and Mk4 Coronagraphs

    Science.gov (United States)

    Frazin, Richard A.; Vasquez, Alberto M.; Thompson, William T.; Hewett, Russell J.; Lamy, Philippe; Llebaria, Antoine; Vourlidas, Angelos; Burkepile, Joan

    2012-01-01

    In order to assess the reliability and consistency of white-light coronagraph measurements, we report on quantitative comparisons between polarized brightness [pB] and total brightness [B] images taken by the following white-light coronagraphs: LASCO-C2 on SOHO, SECCHI-COR1 and -COR2 on STEREO, and the ground-based MLSO-Mk4. The data for this comparison were taken on 16 April 2007, when both STEREO spacecraft were within 3.1 deg. of Earth’s heliographic longitude, affording essentially the same view of the Sun for all of the instruments. Due to the difficulties of estimating stray-light backgrounds in COR1 and COR2, only Mk4 and C2 produce reliable coronal-hole values (but not at overlapping heights), and these cannot be validated without rocket flights or ground-based eclipse measurements. Generally, the agreement between all of the instruments’ pB values is within the uncertainties in bright streamer structures, implying that measurements of bright CMEs also should be trustworthy. Dominant sources of uncertainty and stray light are discussed, as is the design of future coronagraphs from the perspective of the experiences with these instruments.

  18. Seroprevalence and Risk Factors Associated with Seropositivity to Toxoplasma gondii among Stray and Domestic Cats (Felis silvestris catus

    Directory of Open Access Journals (Sweden)

    Christel Bohn T. Garcia

    2014-12-01

    Full Text Available Toxoplasma gondii is a protozoan parasite that causes toxoplasmosis. It is widespread in the environment and infects a variety of warm-blooded animals, causing miscarriages and birth problems. Previous studies in the Philippines have determined the seropositivity of T. gondii in humans. However, the seroprevalence of the parasite among household pets, par ticularly its feline def initive host, remains insufficient . This study aimed to: (1 determine the seroprevalence of T. gondii antibodies among domestic and stray cats in the Philippines; and, (2 to analyze the risk factors associated with seropositivity. Blood samples from 59 domestic and stray cats were collected and tested for T. gondii seropositivity using a commercially available indirect ELISA kit, while pet owners and handlers were given questionnaires about their cats. Thirteen or 22.03% of the cats were seropositive to T. gondii, and risk factor analysis revealed a significant difference between domestic and stray cats with regard to diet (p = 0.026, OR = 8.333, c = 0.299 and domestication (p = 0.039, OR = 5.000, c = 0.276. Cats fed with table food tested 31.43% seropositive compared to the 4.35% of those fed with cat food, whereas 33.33% of the stray cats were seropositive compared to 7.69% for domestic cats. Odds ratio test showed that the risk factors studied were associated with higher likelihood of T. gondii seropositivity. These results implicate diet and environment in the transmission dynamics of T. gondii among cats.

  19. The Coherent X-ray Imaging (CXI) Instrument at the Linac Coherent Light Source (LCLS)

    International Nuclear Information System (INIS)

    Boutet, Sebastien

    2011-01-01

    The Linac Coherent Light Source (LCLS) has become the first ever operational hard X-ray Free Electron Laser in 2009. It will operate as a user facility capable of delivering unique research opportunities in multiple fields of science. The LCLS and the LCLS Ultrafast Science Instruments (LUSI) construction projects are developing instruments designed to make full use of the capabilities afforded by the LCLS beam. One such instrument is being designed to utilize the LCLS coherent beam to image with high resolution any sub-micron object. This instrument is called the Coherent X-ray Imaging (CXI) instrument. This instrument will provide a flexible optical system capable of tailoring key beam parameters for the users. A suite of shot-to-shot diagnostics will also be provided to characterize the beam on every pulse. The provided instrumentation will include multi-purpose sample environments, sample delivery and a custom detector capable of collecting 2D data at 120 Hz. In this article, the LCLS will be briefly introduced along with the technique of Coherent X-ray Diffractive Imaging (CXDI). A few examples of scientific opportunities using the CXI instrument will be described. Finally, the conceptual layout of the instrument will be presented along with a description of the key requirements for the overall system and specific devices required.

  20. Procedure for calibrating the Technicon Colorimeter I.

    Science.gov (United States)

    Black, J C; Furman, W B

    1975-05-01

    We describe a rapid method for calibrating the Technicon AutoAnalyzer colorimeter I. Test solutions of bromphenol blue are recommended for the calibration, in preference to solutions of potassium dichromate, based on considerations of the instrument's working range and of the stray light characteristics of the associated filters.

  1. Decoding of digital magnetic recording with longitudinal magnetization of a tape from a magneto-optical image of stray fields

    Science.gov (United States)

    Lisovskii, F. V.; Mansvetova, E. G.

    2017-05-01

    For digital magnetic recording of encoded information with longitudinal magnetization of the tape, the connection between the domain structure of a storage medium and magneto-optical image of its stray fields obtained using a magnetic film with a perpendicular anisotropy and a large Faraday rotation has been studied. For two-frequency binary code without returning to zero, an algorithm is developed, that allows uniquely decoding of the information recorded on the tape based on analysis of an image of stray fields.

  2. Matrix light and pixel light: optical system architecture and requirements to the light source

    Science.gov (United States)

    Spinger, Benno; Timinger, Andreas L.

    2015-09-01

    Modern Automotive headlamps enable improved functionality for more driving comfort and safety. Matrix or Pixel light headlamps are not restricted to either pure low beam functionality or pure high beam. Light in direction of oncoming traffic is selectively switched of, potential hazard can be marked via an isolated beam and the illumination on the road can even follow a bend. The optical architectures that enable these advanced functionalities are diverse. Electromechanical shutters and lens units moved by electric motors were the first ways to realize these systems. Switching multiple LED light sources is a more elegant and mechanically robust solution. While many basic functionalities can already be realized with a limited number of LEDs, an increasing number of pixels will lead to more driving comfort and better visibility. The required optical system needs not only to generate a desired beam distribution with a high angular dynamic, but also needs to guarantee minimal stray light and cross talk between the different pixels. The direct projection of the LED array via a lens is a simple but not very efficient optical system. We discuss different optical elements for pre-collimating the light with minimal cross talk and improved contrast between neighboring pixels. Depending on the selected optical system, we derive the basic light source requirements: luminance, surface area, contrast, flux and color homogeneity.

  3. An epidemiological survey on intestinal helminths of stray dogs in Mashhad, North-east of Iran.

    Science.gov (United States)

    Emamapour, Seyed Rasoul; Borji, Hassan; Nagibi, Abolghasem

    2015-06-01

    This research was conducted to determine the prevalence of gastrointestinal helminths in stray dogs in the northeast of Iran, with special attention to those parasites that can be transmitted to human. In this experiment, a total of 72 adult and 18 juvenile stray dogs were collected and necropsied for the presence of helminth parasites from October 2011 to August 2012. The overall prevalence of gastrointestinal helminths was 86 % (95 % CI: 79.2-92.8 %). The observed helminths of the gastrointestinal tract were listed as follows: Toxocara canis (29 %), Toxascaris leonina (7 %), Ancylostoma caninum (2 %), Taenia hydatigena (43 %), Dipylidium caninum (39 %), Echinococcus granulosus (38 %), Mesocestoides lineatus (16 %), Taenia multiceps (11 %), Taenia ovis (3 %). There were no significant differences for the prevalence of gastrointestinal helminths between female (83.6 %) and male (89.7 %) and between young (89 %) and adult (72.2 %) animals. However, the prevalence of E. granulosus, T. hydatigena and D. caninum showed an increasing trend with increasing host age, significantly. Based on our data, it is important to point out the presence of zoonotic agents, namely E. granulosus and T. canis in stray dogs in the investigated area. Due to its impact on public health, appropriate control measures should be taken and it is recommended to determine the most appropriate preventive methods.

  4. Experimental investigation of the ECRH stray radiation during the start-up phase in Wendelstein 7-X

    Science.gov (United States)

    Moseev, Dmitry; Laqua, Heinrich; Marsen, Stefan; Stange, Torsten; Braune, Harald; Erckmann, Volker; Gellert, Florian; Oosterbeek, Johann Wilhelm; Wenzel, Uwe

    2017-07-01

    Electron cyclotron resonance heating (ECRH) is the main heating mechanism in the Wendelstein 7-X stellarator (W7-X). W7-X is equipped with five absolutely calibrated sniffer probes that are installed in each of the five modules of the device. The sniffer probes monitor energy flux of unabsorbed ECRH radiation in the device and interlocks are fed with the sniffer probe signals. The stray radiation level in the device changes significantly during the start-up phase: plasma is a strong microwave absorber and during its formation the stray radiation level in sniffer probes reduces by more than 95%. In this paper, we discuss the influence of neutral gas pressure and gyrotron power on plasma breakdown processes.

  5. Prevalence of Protozoa and Gastrointestinal Helminthes in Stray Cats in Zanjan Province, North-West of Iran

    Directory of Open Access Journals (Sweden)

    SA Altome

    2009-07-01

    Full Text Available Background: Cats and other felines act as definitive hosts for many intestinal parasites, some of which are responsible for several zoonotic diseases.  The aim of this study was to determine the type and prevalence of protozoa and gastrointestinal helminthes among stray cats. Methods: A cross sectional study was conducted. Digestive tracts of 100 stray cats in Zanjan Province, north-west of Iran were autopsied in order to recognize gastrointestinal helminthes and intestinal protozoan parasites. These cats were collected by baited cage trapped from October 2007 to September 2008. Gender and species of helminthes and protozoa were rec­ognized using authentic diagnostic criteria. Statistical evaluation was performed by SPSS version 14. Results: Forty-two percent of cats were infected with intestinal protozoan parasites, 33% were infected with cestodes and 39% infected with gastrointestinal nematodes. Four species protozoan parasites and eight gastrointestinal helminthes were recovered from the animals, including Taenia taeniaeformis, Dipylidium spp., Joyeuxiella pasqaulei, Toxocara cati, Phy­saloptera praeputialis, Rectalaria spp., Onicolla, Cystoisospora spp., Toxoplasma gondii, and Sarcocystis spp . Conclusions: The high infection rate of Toxoplasma and some gastrointestinal helminthes in stray cats is considered to be critical from the viewpoint of public health importance.

  6. Prevalence of zoonotic intestinal parasites in household and stray dogs in rural areas of Hamadan, Western Iran.

    Science.gov (United States)

    Sardarian, K; Maghsood, A H; Ghiasian, S A; Zahirnia, A H

    2015-06-01

    Zoonotic parasitic infections are a major global public and veterinary health problem and widespread among dogs. The objective of this study was to assess the prevalence of intestinal parasites in stray and household dogs in the rural areas of Hamadan district. During 2012, 1,500 fresh fecal samples from 243 household and 1,257 stray dogs were examined by using direct wet mount, simple zinc sulfate flotation, and Lugol's solution staining. Of 1,500 dogs, 20.4% were positive for intestinal parasites. Helminthes eggs were more frequently found in fecal samples than protozoan cysts or trophozoites (15.9% vs. 4.5%, respectively). Toxocara canis was the most frequently detected parasite, with a prevalence of 6.3%, followed by Taenia/Echinococcus spp. (2.9%), Isospora spp. (2.7%), and Toxascaris leonina (2.6%). Helminthes and protozoa were significantly more prevalent in household dogs than in stray dogs (Pparasites indicated that people residing in this area are at risk of exposure to these potentially hazardous zoonotic pathogens. Mass education of the general population is highly recommended to increase awareness of the potential for horizontal transmission of these parasitic infections from dogs to humans.

  7. Calibration of passive remote observing optical and microwave instrumentation; Proceedings of the Meeting, Orlando, FL, Apr. 3-5, 1991

    Science.gov (United States)

    Guenther, Bruce W.

    Various papers on the calibration of passive remote observing optical and microwave instrumentation are presented. Individual topics addressed include: on-board calibration device for a wide field-of-view instrument, calibration for the medium-resolution imaging spectrometer, cryogenic radiometers and intensity-stabilized lasers for EOS radiometric calibrations, radiometric stability of the Shuttle-borne solar backscatter ultraviolet spectrometer, ratioing radiometer for use with a solar diffuser, requirements of a solar diffuser and measurements of some candidate materials, reflectance stability analysis of Spectralon diffuse calibration panels, stray light effects on calibrations using a solar diffuser, radiometric calibration of SPOT 23 HRVs, surface and aerosol models for use in radiative transfer codes. Also addressed are: calibrated intercepts for solar radiometers used in remote sensor calibration, radiometric calibration of an airborne multispectral scanner, in-flight calibration of a helicopter-mounted Daedalus multispectral scanner, technique for improving the calibration of large-area sphere sources, remote colorimetry and its applications, spatial sampling errors for a satellite-borne scanning radiometer, calibration of EOS multispectral imaging sensors and solar irradiance variability. (For individual items see A93-23576 to A93-23603)

  8. Generation of strong inhomogeneous stray fields by high-anisotropy permanent magnets

    Energy Technology Data Exchange (ETDEWEB)

    Samofalov, V.N. [National Technical University Kharkov Polytechnical Institute, 21 Frunze St., 61002 Kharkov (Ukraine)]. E-mail: samofalov@kpi.kharkov.ua; Ravlik, A.G. [National Technical University Kharkov Polytechnical Institute, 21 Frunze St., 61002 Kharkov (Ukraine); Belozorov, D.P. [National Scientific Center Kharkov Institute of Physics and Techonology, NAS of Ukraine, 1 Akademicheskaja St., 61108 Kharkov (Ukraine); Avramenko, B.A. [National Technical University Kharkov Polytechnical Institute, 21 Frunze St., 61002 Kharkov (Ukraine)

    2004-10-01

    Magnetic stray fields for systems of permanent magnets with high magnetic anisotropy are calculated and measured. It is shown that intensity of these fields exceeds value of an induction of a material of magnets in some time. Besides, these fields are characterized by high gradients, and size H-bar H can reach values up to10{sup 10}-10{sup 11}Oe{sup 2}/cm. Estimations of extremely achievable fields and their gradients are made.

  9. Stray-field-induced Faraday contributions in wide-field Kerr microscopy and -magnetometry

    International Nuclear Information System (INIS)

    Markó, D.; Soldatov, I.; Tekielak, M.; Schäfer, R.

    2015-01-01

    The magnetic domain contrast in wide-field Kerr microscopy on bulk specimens can be substantially distorted by non-linear, field-dependent Faraday rotations in the objective lens that are caused by stray-field components emerging from the specimen. These Faraday contributions, which were detected by Kerr-magnetometry on grain-oriented iron–silicon steel samples, are thoroughly elaborated and characterized. They express themselves as a field-dependent gray-scale offset to the domain contrast and in highly distorted surface magnetization curves if optically measured in a wide field Kerr microscope. An experimental method to avoid such distortions is suggested. In the course of these studies, a low-permeability part in the surface magnetization loop of slightly misoriented (110)-surfaces in iron–silicon sheets was discovered that is attributed to demagnetization effects in direction perpendicular to the sheet surface. - Highlights: • Magnetizing a finite sample in a Kerr microscope leads to sample-generated stray-fields. • They cause non-linear, field- and position-dependent Faraday rotations in the objective. • This leads to a modulation of the Kerr contrast and to distorted MOKE loops. • A method to compensate these Faraday rotations is presented

  10. LUPIN, a new instrument for pulsed neutron fields

    Energy Technology Data Exchange (ETDEWEB)

    Caresana, M. [Politecnico di Milano, Department of Energy, Via Ponzio 34/3, 20133 Milan (Italy); Ferrarini, M. [Politecnico di Milano, Department of Energy, Via Ponzio 34/3, 20133 Milan (Italy); CNAO, Via Privata Campeggi, 27100 Pavia (Italy); Manessi, G.P., E-mail: giacomo.paolo.manessi@cern.ch [CERN, 1211 Geneva 23 (Switzerland); University of Liverpool, Department of Physics, L69 7ZE Liverpool (United Kingdom); Silari, M. [CERN, 1211 Geneva 23 (Switzerland); Varoli, V. [Politecnico di Milano, Department of Energy, Via Ponzio 34/3, 20133 Milan (Italy)

    2013-06-01

    A number of studies focused in the last decades on the development of survey meters to be used in pulsed radiation fields. This is a topic attracting widespread interest for applications such as radiation protection and beam diagnostics in accelerators. This paper describes a new instrument specifically conceived for applications in pulsed neutron fields (PNF). The detector, called LUPIN, is a rem counter type instrument consisting of a {sup 3}He proportional counter placed inside a spherical moderator. It works in current mode with a front-end electronics consisting of a current–voltage logarithmic amplifier, whose output signal is acquired with an ADC and processed on a PC. This alternative signal processing allows the instrument to be used in PNF without being affected by saturation effects. Moreover, it has a measurement capability ranging over many orders of burst intensity. Despite the fact that it works in current mode, it can measure a single neutron interaction. The LUPIN was first calibrated in CERN's calibration laboratory with a PuBe source. Measurements were carried out under various experimental conditions at the Helmholtz-Zentrum in Berlin, in the stray field at various locations of the CERN Proton Synchrotron complex and around a radiotherapy linear accelerator at the S. Raffaele hospital in Milan. The detector can withstand single bursts with values of H⁎(10) up to 16 nSv/burst without showing any saturation effect. It efficiently works in pulsed stray fields, where a conventional rem-counter underestimates by a factor of 2. It is also able to reject the very intense and pulsed photon contribution that often accompanies the neutron field with good reliability. -- Highlights: ► LUPIN is a new detector specifically conceived to work in neutron pulsed fields. ► The detector is a rem counter type instrument working in current mode. ► The performances of the detectors were studied under various experimental conditions. ► The detector

  11. Solar glint suppression in compact planetary ultraviolet spectrographs

    Science.gov (United States)

    Davis, Michael W.; Cook, Jason C.; Grava, Cesare; Greathouse, Thomas K.; Gladstone, G. Randall; Retherford, Kurt D.

    2015-08-01

    Solar glint suppression is an important consideration in the design of compact photon-counting ultraviolet spectrographs. Southwest Research Institute developed the Lyman Alpha Mapping Project for the Lunar Reconnaissance Orbiter (launch in 2009), and the Ultraviolet Spectrograph on Juno (Juno-UVS, launch in 2011). Both of these compact spectrographs revealed minor solar glints in flight that did not appear in pre-launch analyses. These glints only appeared when their respective spacecraft were operating outside primary science mission parameters. Post-facto scattered light analysis verifies the geometries at which these glints occurred and why they were not caught during ground testing or nominal mission operations. The limitations of standard baffle design at near-grazing angles are discussed, as well as the importance of including surface scatter properties in standard stray light analyses when determining solar keep-out efficiency. In particular, the scattered light analysis of these two instruments shows that standard "one bounce" assumptions in baffle design are not always enough to prevent scattered sunlight from reaching the instrument focal plane. Future builds, such as JUICE-UVS, will implement improved scattered and stray light modeling early in the design phase to enhance capabilities in extended mission science phases, as well as optimize solar keep out volume.

  12. Photon Activation Analysis Of Light Elements Using 'Non-Gamma' Radiation Spectroscopy - The Instrumental Determination Of Phosphorus

    International Nuclear Information System (INIS)

    Segebade, Christian; Goerner, Wolf

    2011-01-01

    Unlike metal determinations the analysis of light elements (e.g., carbon, oxygen, phosphorus) is frequently problematic, in particular if analysed instrumentally. In photon activation analysis (PAA) the respective activation products do not emit gamma radiation in the most cases. Usually, annihilation quanta counting and subsequent decay curve analysis have been used for determinations of C, N, O, and F. However, radiochemical separation of the respective radioisotopes mostly is indispensable. For several reasons, some of the light elements cannot be analysed following this procedure, e.g. phosphorus. In this contribution the instrumental PAA of phosphorus in organic matrix by activation with bremsstrahlung of an electron linear accelerator and subsequent beta spectroscopy is described. The accuracy of the results was excellent as obtained by analysis of a BCR Reference Material.

  13. Investigations of prevalence of antibodies to B.canis in stray dogs in territory of Belgrade

    Directory of Open Access Journals (Sweden)

    Radojičić Sonja

    2006-01-01

    Full Text Available The paper covers investigations of stray dogs in the territory of the city of Belgrade. A total of 184 blood serum samples were examined for the presence of antibodies specific to Brucella canis. The method of slow agglutination in a test tube with 2- mercaptoethanol was used in the diagnostic procedure. Of the 184 examined serums, 49 (26.63% had a titer of 1/50, 25 serums had a titer of 1/100 (13.58%, while 20 serums had a titer equal to or bigger than 1/200 (10.87%. Furthermore, 15 samples of full blood from serologiclly negative animals were also presented for isolation. The bacteriological finding for these samples was negative. The obtained results indicate that the number of seropositive stray dogs in the territory of Belgrade is extremely high and that 10.87% of the testes animals are definitely infected with Brucella canis.

  14. Raman lidar characterization using a reference lamp

    Science.gov (United States)

    Landulfo, Eduardo; da Costa, Renata F.; Rodrigues, Patricia F.; da Silva Lopes, Fábio J.

    2014-10-01

    The determination of the amount of water vapor in the atmosphere using lidar is a calibration dependent technique. Different collocated instruments are used for this purpose, like radiossoundings and microwave radiometers. When there are no collocated instruments available, an independente lamp mapping calibration technique can be used. Aiming to stabilish an independ technique for the calibration of the six channels Nd-YAG Raman lidar system located at the Center for Lasers and Applications (CLA), S˜ao Paulo, Brazil, an optical characterization of the system was first performed using a reference tungsten lamp. This characterization is useful to identify any possible distortions in the interference filters, telescope mirror and stray light contamination. In this paper we show three lamp mapping caracterizations (01/16/2014, 01/22/2014, 04/09/2014). The first day is used to demostrate how the tecnique is useful to detect stray light, the second one how it is sensible to the position of the filters and the third one demostrates a well optimized optical system.

  15. Helminth Infections of Stray Dogs from Garmsar, Semnan Province, Central Iran

    Science.gov (United States)

    Eslami, A; Ranjbar-Bahadori, Sh; Meshgi, B; Dehghan, M; Bokaie, S

    2010-01-01

    Background The aim was to study the gastro-intestinal helminths of stray dogs of Garmsar, Semnan Province, Central Iran, and its impacts on human health and animal production. Methods During 2006, the alimentary tracts of 50 stray dogs at necropsy, selected from villages around Garmsar, were removed, and examined for helminth infections. Subsequently helminths were collected from the contents of each part and scraped sample of small intestines of washed materials in a 100-mesh sieve. To identify the species of helminths, the nematodes were cleared in lactophenol and cestodes were stained using carmine acid. Results Mixed infection was the rule and 40 dogs (80%) harbored more than one species of helminth. Taenia hydatigena was the most prevalent species (80%) followed by Echinococcus granulosus (64%), Toxocara canis (22%), Mesocestoides lineatus (12%), Taenia multiceps (10%) and Dipylidium caninum (4%). The mean intensity of worm infection was low (1–3) except for that of E. granulosus (645). No significant difference was noticed between sex, age and most helminth infections except for that of sex and T. hydatigena (P=0.001) as well as age and T. canis (P=0.001). Conclusion Although human infection with T. hydatigena is unlikely, but other helminths reported in this study are of zoonotic importance, and may pose a threat to community health, and reduce the productions of ruminants harboring taeniid metacestodes. PMID:22347264

  16. A PARASITOLOGIC AND MOLECULAR SURVEY OF HEPATOZOON CANIS INFECTION IN STRAY DOGS IN NORTHEAST OF IRAN.

    Science.gov (United States)

    Barati, Ali; Razmi, Gholamreza

    2018-05-15

    Canine hepatozoonosis, caused by H. canis, is a tick-borne disease in domestic and wild dogs that is transmitted by ingestion of Rhipicephalus sanguineus ticks. The aim of the study was to detect H. canis in stray dogs in Iran using blood smear examination and molecular techniques. From October 2014 to September 2015, 150 EDTA blood samples were collected from stray dogs in the northeast region of Iran. Blood smears were microscopically examined for the presence of Hepatozoon gamonts; whole blood was evaluated by PCR, with subsequent sequencing and phylogenetic analysis. Hepatozoon spp. Gamonts were observed in the neutrophils of 5/150 (3.3%) blood smears, whereas Hepatozoon spp. 18S rDNA was detected in 12/150 (8.0%) blood samples from stray dogs. There was a good agreement between microscopy and PCR methods. (Kappa= 0.756). The highest rate of infection was seasonally detected in the summer (pHepatozoon spp infection was not significant by gender and age factors (p>0.05). The alignment analysis of the sequenced samples showed ≥99% similarity with other nucleotide sequences of Hepatozoon spp. in GenBank. The phylogenetic tree also revealed that the nucleotide sequences in this study were clustered in the H. canis clade and different from the H. felis and H. americanum clades. According to the results, it is concluded that H. canis infection is present among dogs in northeastern region of Iran.

  17. Gastrointestinal Helminthic Parasites in Stray Cats (Felis catus from North of Iran

    Directory of Open Access Journals (Sweden)

    A Rezaei-Doust

    2007-08-01

    Full Text Available Background: Cats play a crucial role in the epidemiology of gastrointestinal helminthic parasites and also play a major role in transmitting of these parasites through faecal contamination of soil, food or water. The aim of this study was to determine the species of gastrointestinal helminthes parasites in stray cats from a rural area of Bandar-e-Anzali, Iran.Method: Gastrointestinal helminthes were collected from 50 necropsied stray cats (Felis catus after capturing them by trapping from different regions of the city and humanely euthanatized in Bandar-e-Anzali, a port in the Caspian Sea in northern Iran, from March to November 2003. Results: The prevalence of infection was 90%, with those of individual parasites being Diplopylidium nolleri 54%, Phy­saloptera praeputialis 32%, Ancylostoma tubaeforme 20%, Joyeuxiella pasqualei 10%, Toxocara cati 8%, Pterygoderma­tites affinis 6%, Ancylostoma caninum 4%, and Taenia taeniaeformis 2%. Concurrent infections with two or more parasites were recorded in 34% of the individuals. In relation to the sex, the differences were not significant. Conclusion: P. praeputialis, T. cati, D. nolleri and sometime J. pasqualei are the commonest Helminthes in cats. This is the first reported isolation of P. affinis and A. caninum infections from cats in Iran.

  18. Comment on "Density functional theory is straying from the path toward the exact functional"

    DEFF Research Database (Denmark)

    Kepp, Kasper Planeta

    2017-01-01

    Medvedev et al (Reports, 6 January 2017, p. 49) argue that recent density functionals stray from the path toward exactness. This conclusion rests on very compact 1s2 and 1s22s2 systems favored by the Hartree-Fock picture. Comparison to actual energies for the same systems indicates that the "stra...

  19. Light Water Reactor Sustainability Program Advanced Instrumentation, Information, and Control Systems Technologies Technical Program Plan for 2013

    Energy Technology Data Exchange (ETDEWEB)

    Hallbert, Bruce [Idaho National Laboratory (INL), Idaho Falls, ID (United States); Thomas, Ken [Idaho National Laboratory (INL), Idaho Falls, ID (United States)

    2014-09-01

    Reliable instrumentation, information, and control (II&C) systems technologies are essential to ensuring safe and efficient operation of the U.S. light water reactor (LWR) fleet. These technologies affect every aspect of nuclear power plant (NPP) and balance-of-plant operations. In 1997, the National Research Council conducted a study concerning the challenges involved in modernization of digital instrumentation and control systems in NPPs. Their findings identified the need for new II&C technology integration.

  20. Nanosurveyor 2: A Compact Instrument for Nano-Tomography at the Advanced Light Source

    Science.gov (United States)

    Celestre, Richard; Nowrouzi, Kasra; Shapiro, David A.; Denes, Peter; Joseph, John M.; Schmid, Andreas; Padmore, Howard A.

    2017-06-01

    The Advanced Light Source has developed a compact tomographic microscope based on soft x-ray ptychography for the study of nanoscale materials [1,2]. The microscope utilizes the sample manipulator mechanism from a commercial TEM coupled with laser interferometric feedback for zone plate positioning and a fast frame rate charge-coupled device detector for soft x-ray diffraction measurements. The microscope has achieved point to point (25 nm steps) scan rates of greater than 120 Hz with a positioning accuracy of better than 1 nm RMS. The instrument will enable the use of commercially available sample holders compatible with FEI transmission electron microscopes thus also allowing in-situ measurement of samples using both soft x-rays and electrons. This instrument is a refinement of a currently commissioned instrument called The Nanosurveyor, which has demonstrated resolution of better than 10 nm in two dimensions using 750 eV x-rays. Once moved to the new Coherent Scattering and Microscopy beamline it will enable spectromicroscopy and tomography of nano-materials with wavelength limited spatial resolution.

  1. Barged/In-river steelhead migrant data - Evaluation of methods to reduce straying rates of barged juvenile steelhead

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The goals of this study are to develop methods to reduce wandering and straying of steelhead (Oncorhynchus mykiss) that are collected and barged from the Snake River...

  2. Laboratory data on Snake River steelhead - Evaluation of methods to reduce straying rates of barged juvenile steelhead

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The goals of this study are to develop methods to reduce wandering and straying of steelhead (Oncorhynchus mykiss) that are collected and barged from the Snake River...

  3. A survey study on gastrointestinal parasites of stray cats in northern region of Nile delta, Egypt.

    Directory of Open Access Journals (Sweden)

    Reda E Khalafalla

    Full Text Available A survey study on gastrointestinal parasites in 113 faecal samples from stray cats collected randomly from Kafrelsheikh province, northern region of Nile delta of Egypt; was conducted in the period between January and May 2010. The overall prevalence was 91%. The results of this study reported seven helminth species: Toxocara cati (9%, Ancylostoma tubaeforme (4%, Toxascaris leonina (5%, Dipylidium caninum (5%, Capillaria spp. (3%, Taenia taeniformis (22% and Heterophyes heterophyes (3%, four protozoal species: Toxoplasma gondii (9%, Sarcocyst spp. (1%, Isospora spp. (2% and Giardia spp. (2% and two arthropod species; Linguatula serrata (2% and mites eggs (13%. The overall prevalence of intestinal parasites may continue to rise due to lack of functional veterinary clinics for cat care in Egypt. Therefore, there is a need to plan adequate control programs to diagnose, treat and control gastrointestinal parasites of companion as well as stray cats in the region.

  4. A Survey Study on Gastrointestinal Parasites of Stray Cats in Northern Region of Nile Delta, Egypt

    Science.gov (United States)

    Khalafalla, Reda E.

    2011-01-01

    A survey study on gastrointestinal parasites in 113 faecal samples from stray cats collected randomly from Kafrelsheikh province, northern region of Nile delta of Egypt; was conducted in the period between January and May 2010. The overall prevalence was 91%. The results of this study reported seven helminth species: Toxocara cati (9%), Ancylostoma tubaeforme (4%), Toxascaris leonina (5%), Dipylidium caninum (5%), Capillaria spp. (3%), Taenia taeniformis (22%) and Heterophyes heterophyes (3%), four protozoal species: Toxoplasma gondii (9%), Sarcocyst spp. (1%), Isospora spp. (2%) and Giardia spp. (2%) and two arthropod species; Linguatula serrata (2%) and mites eggs (13%). The overall prevalence of intestinal parasites may continue to rise due to lack of functional veterinary clinics for cat care in Egypt. Therefore, there is a need to plan adequate control programs to diagnose, treat and control gastrointestinal parasites of companion as well as stray cats in the region. PMID:21760884

  5. Helminth Infections of Stray Dogs from Garmsar, Semnan Province, Central Iran

    Directory of Open Access Journals (Sweden)

    A Eslami

    2010-12-01

    Full Text Available Background: The aim was to study the gastro-intestinal helminths of stray dogs of Garmsar, Sem­nan Province, Central Iran, and its impacts on human health and animal production.Methods: During 2006, the alimentary tracts of 50 stray dogs at necropsy, selected from villages around Garmsar, were removed, and examined for helminth infections. Subsequently helminths were collected from the contents of each part and scraped sample of small intestines of washed materials in a 100-mesh sieve. To identify the species of helminths, the nematodes were cleared in lactophenol and cestodes were stained using carmine acid.Results: Mixed infection was the rule and 40 dogs (80% harbored more than one species of helminth. Taenia hydatigena was the most prevalent species (80% followed by Echinococcus granulosus (64%, Toxocara canis (22%, Mesocestoides lineatus (12%, Taenia multiceps (10% and Dipylidium caninum (4%. The mean intensity of worm infection was low (1-3 ex­cept for that of E. granulosus (645. No significant difference was noticed between sex, age and most helminth infections except for that of sex and T. hydatigena (P=0.001 as well as age and T. canis (P=0.001.Conclusion: Although human infection with T. hydatigena is unlikely, but other helminths re­ported in this study are of zoonotic importance, and may pose a threat to community health, and reduce the productions of ruminants harboring taeniid metacestodes.

  6. A Preliminary Study on the Helminth Fauna in Necropsied Stray Cats (Felis catus in Beni-Suef, Egypt

    Directory of Open Access Journals (Sweden)

    Khaled Mohamed El-Dakhly

    2017-10-01

    Full Text Available Stray cats play a crucial role in the epidemiology of endoparasites, particularly helminths, due to predating a wide range of both vertebrate and invertebrate hosts, often of veterinary and zoonotic importance. Therefore, a total of 62 stray cats were necropsied in Beni-Suef province, Egypt and examined for helminth parasites. The overall prevalence of infection was 87.0%. The recovered helminths consisted of 10 species of trematodes (Heterophyes heterophyes, Pygidiopsis summa, H. nocens, Echinochasmus liliputanus, Alaria sp., Procerovum varium, Ascocotyle sp., Haplorchis sp., Prohemistomum vivax, Euparadistomum herpestesi, five cestodes (Dipylidium caninum, Diplopylidium acanthoterta, D. nolleri, Joyeuxiella sp. and Taenia taeniaeformis, and two nematodes (Toxascaris leonina and larvae of Anisakis simplex. The most prevalent helminths were Dipylidium caninum (62.9%, Toxascaris leonina (33.8%, Diplopylidium nolleri (22.5% and Echinochasmus liliputanus (6.45%. Thirty (48.39% cats were co-infected by one species, 22 (35.48% by two and three (4.84% by more than two species. It has been found that cats aged more than 3 years were the most infected. Both male and female cats were parasitized. The infection was the most prevalent in both summer and autumn. In conclusion, veterinarians must highlight more attention towards both stray and domestic cats, as they are considered reservoir hosts for a wide host range of parasites, particularly helminths, and the zoonotic importance of such parasites should be taken on consideration.

  7. Instrument intercomparison in the high-energy mixed field at the CERN-EU reference field (CERF) facility

    CERN Document Server

    Caresana, Marco; Manessi, Giacomo; Ott, Klaus; Scherpelz, Robert; Silari, Marco

    2014-01-01

    This paper discusses an intercomparison campaign performed in the mixed radiation field at the CERN-EU (CERF) reference field facility. Various instruments were employed: conventional and extended-range rem counters including a novel instrument called LUPIN, a bubble detector using an active counting system (ABC 1260) and two tissue-equivalent proportional counters (TEPCs). The results show that the extended range instruments agree well within their uncertainties and within 1σ with the H*(10) FLUKA value. The conventional rem counters are in good agreement within their uncertainties and underestimate H*(10) as measured by the extended range instruments and as predicted by FLUKA. The TEPCs slightly overestimate the FLUKA value but they are anyhow consistent with it when taking the comparatively large total uncertainties into account, and indicate that the non-neutron part of the stray field accounts for ∼30 % of the total H*(10).

  8. Characteristics and performance of the Los Alamos VUV beamline at the NSLS

    International Nuclear Information System (INIS)

    Bartlett, R.J.; Trela, W.J.; Michaud, F.D.; Southworth, S.H.; Alkire, R.W.; Roy, P.; Rothe, R.; Walsh, P.J.; Shinn, N.

    1988-01-01

    We describe the design and performance of the Los Alamos VUV synchrotron radiation beamline, U3C, on the VUV ring of the National Synchrotron Light Source at Brookhaven National Laboratory. The beamline uses separate function optics to collect and focus the horizontally and vertically diverging beam. The monochromator is a grazing incidence Rowland circle instrument of the extended grasshopper design (ERG). A postmonochromator refocusing mirror is used to focus or collimate the diverging beam from the monochromator. The beamline control and diagnostics systems are also discussed. Particular emphasis in the design has been placed on the reduction of stray and harmonic light. Higher order light is reduced by a grazing angle mirror low pass filter installed immediately downstream from the monochromator while stray light is reduced through the use of baffles and thin film filters. Also included in the line is a differential pumping section that permits gas phase and other experiments requiring pressures in the 10 -5 to 10 -4 Torr range to be coupled to the beamline. (orig.)

  9. Some aspects of stray losses in large power transformers

    International Nuclear Information System (INIS)

    Valkovic, Zvonimir

    2002-01-01

    The paper presents some results of the investigation of stray losses in power transformers that are caused by high-current loops. The investigation was focused on: a) additional losses in tank cover around high-current bushings and the way of their reduction, b) extra leakage flux and additional losses due to high current delta-connections. The insertion of nonmagnetic gaps between the phase bushings reduces the extra cover losses more than three times. A nonmagnetic plate around the high-current bushings reduces these extra losses practically to zero. The extra losses due to the high-current delta-connections could be significant for the transformer loss level. These extra losses could be controlled (reduced) by the design layout of the delta-connections. (Author)

  10. Possibility of reducing stray losses and parasitic torques in two-phase emergency feeding of induction motors

    Czech Academy of Sciences Publication Activity Database

    Schreier, Luděk; Bendl, Jiří; Chomát, Miroslav; Klíma, J.

    2006-01-01

    Roč. 51, č. 2 (2006), s. 109-131 ISSN 0001-7043 R&D Projects: GA ČR(CZ) GA102/04/0215 Institutional research plan: CEZ:AV0Z20570509 Keywords : induction motor * emergency operation of electrical drives * stray losses Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  11. Light Water Reactor Sustainability Program Advanced Instrumentation, Information, and Control Systems Technologies Technical Program Plan for FY 2016

    Energy Technology Data Exchange (ETDEWEB)

    Hallbert, Bruce Perry [Idaho National Lab. (INL), Idaho Falls, ID (United States); Thomas, Kenneth David [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-10-01

    Reliable instrumentation, information, and control (II&C) systems technologies are essential to ensuring safe and efficient operation of the U.S. light water reactor (LWR) fleet. These technologies affect every aspect of nuclear power plant (NPP) and balance-of-plant operations. In 1997, the National Research Council conducted a study concerning the challenges involved in modernization of digital instrumentation and control systems in NPPs. Their findings identified the need for new II&C technology integration.

  12. Magnetic charge distribution and stray field landscape of asymmetric néel walls in a magnetically patterned exchange bias layer system

    Science.gov (United States)

    Zingsem, Norbert; Ahrend, Florian; Vock, Silvia; Gottlob, Daniel; Krug, Ingo; Doganay, Hatice; Holzinger, Dennis; Neu, Volker; Ehresmann, Arno

    2017-12-01

    The 3D stray field landscape above an exchange bias layer system with engineered domain walls has been fully characterized by quantitative magnetic force microscopy (qMFM) measurements. This method is based on a complete quantification of the MFM tip’s imaging properties and the subtraction of its contribution from the measured MFM data by deconvolution in Fourier space. The magnetically patterned Ir17Mn83/Co70Fe30-exchange-bias-multilayers have been designed to contain asymmetric head-to-head (hh)/tail-to-tail (tt) Néel walls between domains of different magnetic anisotropies for potential use in guided particle transport. In the current application, qMFM reveals the effective magnetic charge profile on the surface of the sample—with high spatial resolution and in an absolute quantitative manner. These data enable to calculate the magnetostatic potential and the full stray field landscape above the sample surface. It has been successfully tested against: (i) micromagnetic simulations of the magnetization structure of a comparable exchange-bias layer system, (ii) measurements of the magnetization profile across the domain boundary with x-ray photoemission electron microscopy, and (iii) direct stray field measurements obtained by scanning Hall probe microscopy at elevated scan heights. This approach results in a quantitative determination of the stray field landscape at close distances to the sample surface, which will be of importance for remote magnetic particle transport applications in lab-on-a-chip devices. Furthermore, the highly resolving and quantitative MFM approach reveals details of the domain transition across the artificially structured phase boundary, which have to be attributed to a continuous change in the materials parameters across this boundary, rather than an abrupt one.

  13. Surgical instrument biocontaminant fluorescence detection in ambient lighting conditions for hospital reprocessing and sterilization department (Conference Presentation)

    Science.gov (United States)

    Baribeau, François; Bubel, Annie; Dumont, Guillaume; Vachon, Carl; Lépine, André; Rochefort, Stéphane; Massicotte, Martin; Buteau-Vaillancourt, Louis; Gallant, Pascal; Mermut, Ozzy

    2017-03-01

    Hospitals currently rely on simple human visual inspection for assessing cleanliness of surgical instruments. Studies showed that surgical site infections are in part attributed to inadequate cleaning of medical devices. Standards groups recognize the need to objectively quantify the amount of residues on surgical instruments and establish guidelines. We developed a portable technology for the detection of contaminants on surgical instruments through fluorescence following cleaning. Weak fluorescence signals are usually detected in the obscurity only with the lighting of the excitation source. The key element of this system is that it works in ambient lighting conditions, a requirement to not disturb the normal workflow of hospital reprocessing facilities. A biocompatible fluorescent dye is added to the detergent and labels the proteins of organic residues. It is resistant to the harsh environment in a washer-disinfector. Two inspection devices have been developed with a 488nm laser as the excitation source: a handheld scanner and a tabletop station using spectral-domain and time-domain ambient light cancellation schemes. The systems are eye safe and equipped with image processing and interfacing software to provide visual or audible warnings to the operator based on a set of adjustable signal thresholds. Micron-scale residues are detected by the system which can also evaluate soil size and mass. Unlike swabbing, it can inspect whole tools in real-time. The technology has been validated in an independent hospital decontamination research laboratory. It also has potential applications in the forensics, agro-food, and space fields. Technical aspects and results will be presented and discussed.

  14. 3D Printing of Polymer-Bonded Rare-Earth Magnets With a Variable Magnetic Compound Fraction for a Predefined Stray Field.

    Science.gov (United States)

    Huber, Christian; Abert, Claas; Bruckner, Florian; Groenefeld, Martin; Schuschnigg, Stephan; Teliban, Iulian; Vogler, Christoph; Wautischer, Gregor; Windl, Roman; Suess, Dieter

    2017-08-25

    Additive manufacturing of polymer-bonded magnets is a recently developed technique, for single-unit production, and for structures that have been impossible to manufacture previously. Also, new possibilities to create a specific stray field around the magnet are triggered. The current work presents a method to 3D print polymer-bonded magnets with a variable magnetic compound fraction distribution. This means the saturation magnetization can be adjusted during the printing process to obtain a required external field of the manufactured magnets. A low-cost, end-user 3D printer with a mixing extruder is used to mix permanent magnetic filaments with pure polyamide (PA12) filaments. The magnetic filaments are compounded, extruded, and characterized for the printing process. To deduce the quality of the manufactured magnets with a variable magnetic compound fraction, an inverse stray field framework is developed. The effectiveness of the printing process and the simulation method is shown. It can also be used to manufacture magnets that produce a predefined stray field in a given region. This opens new possibilities for magnetic sensor applications. This setup and simulation framework allows the design and manufacturing of polymer-bonded permanent magnets, which are impossible to create with conventional methods.

  15. Toxocara nematodes in stray cats from shiraz, southern iran: intensity of infection and molecular identification of the isolates.

    Directory of Open Access Journals (Sweden)

    Fattaneh Mikaeili

    2013-12-01

    Full Text Available Toxocara is a common nematode of cats in different parts of Iran. Despite the close association of cats with human, no attempt has been done so far for molecular identification of this nematode in the country. Therefore, current study was performed on identification of some isolates of Toxocara from stray cats in Shiraz, Fars Province, Southern Iran, based on morphological and molecular approaches, and also determination of intensity of infection.This cross-sectional study was carried out on 30 stray cats trapped from different geographical areas of Shiraz in 2011. Adult male and female worms were recovered from digestive tract after dissection of cats. Morphological features using existing keys and PCR-sequencing of ITS-rDNA region and pcox1 mitochondrial l gene were applied for the delineating the species of the parasites.Eight out of 30 cats (26.7% were found infected with Toxocara nematodes. All the isolates were confirmed as Toxocara cati based on morphological features and the sequence of ribosomal and mitochondrial targets. Intensity of infection ranged from one to a maximum of 39 worms per cat, with a mean of 10.25±12.36, and higher abundance of female nematodes.The most prevalent ascaridoid nematode of stray cats in the study area was T. cati and female nematodes were more abundant than that of males. This issue has important role in spreading of eggs in the environment and impact on human toxocariasis.

  16. Instrument intercomparison in the high-energy mixed field at the CERN-EU reference field (CERF) facility.

    Science.gov (United States)

    Caresana, Marco; Helmecke, Manuela; Kubancak, Jan; Manessi, Giacomo Paolo; Ott, Klaus; Scherpelz, Robert; Silari, Marco

    2014-10-01

    This paper discusses an intercomparison campaign performed in the mixed radiation field at the CERN-EU (CERF) reference field facility. Various instruments were employed: conventional and extended-range rem counters including a novel instrument called LUPIN, a bubble detector using an active counting system (ABC 1260) and two tissue-equivalent proportional counters (TEPCs). The results show that the extended range instruments agree well within their uncertainties and within 1σ with the H*(10) FLUKA value. The conventional rem counters are in good agreement within their uncertainties and underestimate H*(10) as measured by the extended range instruments and as predicted by FLUKA. The TEPCs slightly overestimate the FLUKA value but they are anyhow consistent with it when taking the comparatively large total uncertainties into account, and indicate that the non-neutron part of the stray field accounts for ∼30 % of the total H*(10). © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Advanced Instrumentation, Information, and Control Systems Technologies Research in Support of Light Water Reactors

    International Nuclear Information System (INIS)

    Hallbert, Bruce P.; Kenneth, Thomas

    2014-01-01

    The Advanced Instrumentation, Information, and Control (II and C) Systems Technologies Pathway conducts targeted research and development (R and D) to address aging and reliability concerns with the legacy instrumentation and control and related information systems of the U.S. operating light water reactor (LWR) fleet. This work involves two major goals to ensure that legacy analog II and C systems are not life-limiting issues for the LWR fleet, and to implement digital II and C technology in a manner that enables broad innovation and business improvement in the nuclear power plant operating model. Resolving long-term operational concerns with the II and C systems contributes to the long-term sustainability of the LWR fleet, which is vital to the nation's energy and environmental security

  18. Advanced Instrumentation, Information, and Control Systems Technologies Research in Support of Light Water Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Hallbert, Bruce P.; Kenneth, Thomas [Idaho National Laboratory, Idaho (United States)

    2014-08-15

    The Advanced Instrumentation, Information, and Control (II and C) Systems Technologies Pathway conducts targeted research and development (R and D) to address aging and reliability concerns with the legacy instrumentation and control and related information systems of the U.S. operating light water reactor (LWR) fleet. This work involves two major goals to ensure that legacy analog II and C systems are not life-limiting issues for the LWR fleet, and to implement digital II and C technology in a manner that enables broad innovation and business improvement in the nuclear power plant operating model. Resolving long-term operational concerns with the II and C systems contributes to the long-term sustainability of the LWR fleet, which is vital to the nation's energy and environmental security.

  19. Marginalizing Instrument Systematics in HST WFC3 Transit Light Curves

    Science.gov (United States)

    Wakeford, H. R.; Sing, D. K.; Evans, T.; Deming, D.; Mandell, A.

    2016-03-01

    Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) infrared observations at 1.1-1.7 μm probe primarily the H2O absorption band at 1.4 μm, and have provided low-resolution transmission spectra for a wide range of exoplanets. We present the application of marginalization based on Gibson to analyze exoplanet transit light curves obtained from HST WFC3 to better determine important transit parameters such as Rp/R*, which are important for accurate detections of H2O. We approximate the evidence, often referred to as the marginal likelihood, for a grid of systematic models using the Akaike Information Criterion. We then calculate the evidence-based weight assigned to each systematic model and use the information from all tested models to calculate the final marginalized transit parameters for both the band-integrated and spectroscopic light curves to construct the transmission spectrum. We find that a majority of the highest weight models contain a correction for a linear trend in time as well as corrections related to HST orbital phase. We additionally test the dependence on the shift in spectral wavelength position over the course of the observations and find that spectroscopic wavelength shifts {δ }λ (λ ) best describe the associated systematic in the spectroscopic light curves for most targets while fast scan rate observations of bright targets require an additional level of processing to produce a robust transmission spectrum. The use of marginalization allows for transparent interpretation and understanding of the instrument and the impact of each systematic evaluated statistically for each data set, expanding the ability to make true and comprehensive comparisons between exoplanet atmospheres.

  20. Portable dynamic light scattering instrument and method for the measurement of blood platelet suspensions

    International Nuclear Information System (INIS)

    Maurer-Spurej, Elisabeth; Brown, Keddie; Labrie, Audrey; Marziali, Andre; Glatter, Otto

    2006-01-01

    No routine test exists to determine the quality of blood platelet transfusions although every year millions of patients require platelet transfusions to survive cancer chemotherapy, surgery or trauma. A new, portable dynamic light scattering instrument is described that is suitable for the measurement of turbid solutions of large particles under temperature-controlled conditions. The challenges of small sample size, short light path through the sample and accurate temperature control have been solved with a specially designed temperature-controlled sample holder for small diameter, disposable capillaries. Efficient heating and cooling is achieved with Peltier elements in direct contact with the sample capillary. Focusing optical fibres are used for light delivery and collection of scattered light. The practical use of this new technique was shown by the reproducible measurement of latex microspheres and the temperature-induced morphological changes of human blood platelets. The measured parameters for platelet transfusions are platelet size, number of platelet-derived microparticles and the response of platelets to temperature changes. This three-dimensional analysis provides a high degree of confidence for the determination of platelet quality. The experimental data are compared to a matrix and facilitate automated, unbiased quality testing

  1. Measurement of stray neutron doses inside the treatment room from a proton pencil beam scanning system

    Czech Academy of Sciences Publication Activity Database

    Mojzeszek, N.; Farah, J.; Klodowska, M.; Ploc, Ondřej; Stolarczyk, L.; Waligorski, M. P. R.; Olko, P.

    2017-01-01

    Roč. 34, č. 2 (2017), s. 80-84 ISSN 1120-1797 Institutional support: RVO:61389005 Keywords : secondary neutrons * proton therapy * pencil beam scanning systtems * out-of-field doses * stray neutron doses * TEPC Subject RIV: FP - Other Medical Disciplines OBOR OECD: Radiology, nuclear medicine and medical imaging Impact factor: 1.990, year: 2016

  2. Probing of Hermean Exosphere by ultraviolet spectroscopy: Instrument presentation, calibration philosophy and first lights results

    Science.gov (United States)

    Mariscal, J. F.; Rouanet, N.; Maria, J. L.; Quémerais, E.; Mine, P. O.; Zuppella, P.; Suman, M.; Nicolosi, P.; Pelizzo, M. G.; Yoshikawa, I.; Yoshioka, K.; Murakami, G.

    2017-11-01

    PHEBUS (Probing of Hermean Exosphere by Ultraviolet Spectroscopy) is a double spectrometer for the Extreme Ultraviolet range (55-155 nm) and the Far Ultraviolet range (145-315 nm) dedicated to the characterization of Mercury's exosphere composition and dynamics, and surface-exosphere connections. PHEBUS is part of the ESA BepiColombo cornerstone mission payload devoted to the study of Mercury. The BepiColombo mission consists of two spacecrafts: the Mercury Magnetospheric Orbiter (MMO) and the Mercury Planetary Orbiter (MPO) on which PHEBUS will be mounted. PHEBUS is a French-led instrument implemented in a cooperative scheme involving Japan (detectors), Russia (scanner) and Italy (ground calibration). Before launch, PHEBUS team want to perform a full absolute calibration on ground, in addition to calibrations which will be made in-flight, in order to know the instrument's response as precisely as possible. Instrument overview and calibration philosophy are introduced along with the first lights results observed by a first prototype.

  3. Humoral immune response to Dipylidium caninum infection of stray dogs in Taiwan.

    Science.gov (United States)

    Shin, J W; Liao, W T

    2002-04-02

    Two kinds of homogeneous proglottid, mature and gravid, of Dipylidium caninum were used as the antigens for immunodiagnosis of canine dipylidiosis in stray dogs in Tainan, Taiwan. The ELISA was performed on 30 serum samples; 24 from dipylidiosis, four from ancylostomosis and two from toxocariosis. The ELISA have specificity and sensitive of 100 and 50% for mature proglottid extract, and 75 and 100%, respectively, for gravid proglottid extract. EITB technique showed two major peptide bands of 94.8 and 97.9kDa were recognized in the sera pool of infected dogs.

  4. Induced radioactivity of materials by stray radiation fields at an electron accelerator

    CERN Document Server

    Rokni, S H; Gwise, T; Liu, J C; Roesler, S

    2002-01-01

    Samples of soil, water, aluminum, copper and iron were irradiated in the stray radiation field generated by the interaction of a 28.5 GeV electron beam in a copper-dump in the Beam Dump East facility at the Stanford Linear Accelerator Center. The specific activity induced in the samples was measured by gamma spectroscopy and other techniques. In addition, the isotope production in the samples was calculated with detailed Monte Carlo simulations using the FLUKA code. The calculated activities are compared to the experimental values and differences are discussed.

  5. Factors affecting the prevalence of mange-mite infestations in stray dogs of Yucatán, Mexico.

    Science.gov (United States)

    Rodriguez-Vivas, R I; Ortega-Pacheco, A; Rosado-Aguilar, J A; Bolio, G M E

    2003-07-10

    The aim of the present study was to determine the factors affecting the prevalence of mange-mite infestations in stray dogs of Yucatán, Mexico. The study was carried out in 200 stray dogs of Mérida capital city of Yucatán, Mexico. Four samples (head, thoracic-abdominal area, extremities and ear) were taken from each animal by skin scraping and examined microscopically in 10% KOH solution to detect the presence of mites. Mites were also collected from the external ear canal of dogs using cotton-tipped swabs. The prevalence of different mite species was calculated. A primary screening was performed using 2xK contingency tables of exposure variables. All variables with PDemodex canis (23.0%) was the most frequent mite, followed by Sarcoptes scabei var. canis (7.0%) and Otodectes cynotis (3.5%). The following factors were found: body condition (bad, OR: 5.35, CI 95%: 1.66-17.3; regular, OR: 3.72, CI 95%: 1.39-9.99) and the presence of macroscopic lesions of dermatosis (OR: 42.80, CI 95%: 13.65-134.24).

  6. Antibody Detection to Feline Immunodeficiency virus (FIV in stray cats in Ahvaz, southwestern Iran

    Directory of Open Access Journals (Sweden)

    Mosallanejad, B.

    2010-01-01

    Full Text Available The present study was performed to determine the prevalence of FIV in stray cat's population of Ahvaz different area. Serum samples were collected from 90 cats from 2005 to 2007. The studied cats were divided into two age groups (3 years and based on clinical signs (such as lymphadenopathy, periodontal diseases, gingivitis, abscess and cashecsi into two groups also. The results were analyzed using Fischer's exact test and Chi-square analysis. Prevalence to FIV antibodies in these cats was 15.55% (14 of 90 by means of ELISA Test Kit, indicating that this virus is present in the ecosystem. The infection had more prevalence in cats above 3 years (78.6%; 11 of 14 compared with cats less than 3 years (21.4%; 3 of 14. Statistical analysis showed significant difference between different age groups (P0.05. Three out of 12 cases (25% which had clinical signs and 11 out of 78 cases (14.1% which hadn’t clinical signs were seropositive. There was no significant difference between the two groups also (P>0.05. This study showed that FIV exist among cat's population of Ahvaz area and separation of companion and stray cats is very important for prevention of disease transmission to companion cats.

  7. Community perception regarding rabies prevention and stray dog control in urban slums in India.

    Science.gov (United States)

    Herbert, Mrudu; Riyaz Basha, S; Thangaraj, Selvi

    2012-12-01

    The lack of community awareness about rabies control is a major issue that thwarts efforts to prevent human deaths caused by rabies. The objectives of this study were (1) to assess community knowledge and attitudes about rabies, rabies prevention and stray dog control in an urban slum community and (2) to determine the factors that influence rabies awareness in urban slums. Using a systematic random sampling strategy, 185 participants were selected from 8 urban slums. The data were collected by direct interview using a pre-tested, structured questionnaire. In the study population, 74.1% of the participants had heard about rabies, and 54.1% knew that rabies is a fatal disease. Only 33.5% of the interviewees felt that people in the community had a role to play in controlling the stray dog population. Gender, age and educational status were significantly associated with rabies awareness. Our study indicates that there are gaps in the knowledge and attitudes of individuals living in urban slums regarding rabies prevention and control. Efforts to promote awareness should be targeted at men, older people and uneducated individuals. Copyright © 2012 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  8. Instrumentation and method for measuring NIR light absorbed in tissue during MR imaging in medical NIRS measurements

    Science.gov (United States)

    Myllylä, Teemu S.; Sorvoja, Hannu S. S.; Nikkinen, Juha; Tervonen, Osmo; Kiviniemi, Vesa; Myllylä, Risto A.

    2011-07-01

    Our goal is to provide a cost-effective method for examining human tissue, particularly the brain, by the simultaneous use of functional magnetic resonance imaging (fMRI) and near-infrared spectroscopy (NIRS). Due to its compatibility requirements, MRI poses a demanding challenge for NIRS measurements. This paper focuses particularly on presenting the instrumentation and a method for the non-invasive measurement of NIR light absorbed in human tissue during MR imaging. One practical method to avoid disturbances in MR imaging involves using long fibre bundles to enable conducting the measurements at some distance from the MRI scanner. This setup serves in fact a dual purpose, since also the NIRS device will be less disturbed by the MRI scanner. However, measurements based on long fibre bundles suffer from light attenuation. Furthermore, because one of our primary goals was to make the measuring method as cost-effective as possible, we used high-power light emitting diodes instead of more expensive lasers. The use of LEDs, however, limits the maximum output power which can be extracted to illuminate the tissue. To meet these requirements, we improved methods of emitting light sufficiently deep into tissue. We also show how to measure NIR light of a very small power level that scatters from the tissue in the MRI environment, which is characterized by strong electromagnetic interference. In this paper, we present the implemented instrumentation and measuring method and report on test measurements conducted during MRI scanning. These measurements were performed in MRI operating rooms housing 1.5 Tesla-strength closed MRI scanners (manufactured by GE) in the Dept. of Diagnostic Radiology at the Oulu University Hospital.

  9. A Consistent EPIC Visible Channel Calibration Using VIIRS and MODIS as a Reference.

    Science.gov (United States)

    Haney, C.; Doelling, D. R.; Minnis, P.; Bhatt, R.; Scarino, B. R.; Gopalan, A.

    2017-12-01

    The Earth Polychromatic Imaging Camera (EPIC) aboard the Deep Space Climate Observatory (DSCOVR) satellite constantly images the sunlit disk of Earth from the Lagrange-1 (L1) point in 10 spectral channels spanning the UV, VIS, and NIR spectrums. Recently, the DSCOVR EPIC team has publicly released version 2 dataset, which has implemented improved navigation, stray-light correction, and flat-fielding of the CCD array. The EPIC 2-year data record must be well-calibrated for consistent cloud, aerosol, trace gas, land use and other retrievals. Because EPIC lacks onboard calibrators, the observations made by EPIC channels must be calibrated vicariously using the coincident measurements from radiometrically stable instruments that have onboard calibration systems. MODIS and VIIRS are best-suited instruments for this task as they contain similar spectral bands that are well-calibrated onboard using solar diffusers and lunar tracking. We have previously calibrated the EPIC version 1 dataset by using EPIC and VIIRS angularly matched radiance pairs over both all-sky ocean and deep convective clouds (DCC). We noted that the EPIC image required navigations adjustments, and that the EPIC stray-light correction provided an offset term closer to zero based on the linear regression of the EPIC and VIIRS ray-matched radiance pairs. We will evaluate the EPIC version 2 navigation and stray-light improvements using the same techniques. In addition, we will monitor the EPIC channel calibration over the two years for any temporal degradation or anomalous behavior. These two calibration methods will be further validated using desert and DCC invariant Earth targets. The radiometric characterization of the selected invariant targets is performed using multiple years of MODIS and VIIRS measurements. Results of these studies will be shown at the conference.

  10. Synchrotron light sources and free-electron lasers accelerator physics, instrumentation and science applications

    CERN Document Server

    Khan, Shaukat; Schneider, Jochen; Hastings, Jerome

    2016-01-01

    Hardly any other discovery of the nineteenth century did have such an impact on science and technology as Wilhelm Conrad Röntgen’s seminal find of the X-rays. X-ray tubes soon made their way as excellent instruments for numerous applications in medicine, biology, materials science and testing, chemistry and public security. Developing new radiation sources with higher brilliance and much extended spectral range resulted in stunning developments like the electron synchrotron and electron storage ring and the freeelectron laser. This handbook highlights these developments in fifty chapters. The reader is given not only an inside view of exciting science areas but also of design concepts for the most advanced light sources. The theory of synchrotron radiation and of the freeelectron laser, design examples and the technology basis are presented. The handbook presents advanced concepts like seeding and harmonic generation, the booming field of Terahertz radiation sources and upcoming brilliant light sources dri...

  11. Robust sensor for turbidity measurement from light scattering and absorbing liquids.

    Science.gov (United States)

    Kontturi, Ville; Turunen, Petri; Uozumi, Jun; Peiponen, Kai-Erik

    2009-12-01

    Internationally standardized turbidity measurements for probing solid particles in liquid are problematic in the case of simultaneous light scattering and absorption. A method and a sensor to determine the turbidity in the presence of light absorption are presented. The developed sensor makes use of the total internal reflection of a laser beam at the liquid-prism interface, and the turbidity is assessed using the concept of laser speckle pattern. Using average filtering in speckle data analyzing the observed dynamic speckle pattern, which is due to light scattering from particles and the static speckle due to stray light of the sensor, can be separated from each other. Good correlation between the standard deviation of dynamic speckle and turbidity value for nonabsorbing and for absorbing liquids was observed. The sensor is suggested, for instance, for the measurement of ill-behaved as well as small-volume turbid liquids in both medicine and process industry.

  12. Synchrotron light beam and a synchrotron light experiment facility

    International Nuclear Information System (INIS)

    Ando, Masami

    1980-01-01

    In the National Laboratory for High Energy Physics, about two years ago, the requirements of synchrotron light beam in respective measuring instruments were discussed. Then, also the arrangement (lattice) of a storage ring, the nature of synchrotron light beam, a synchrotron light experiment facility and the arrangement of the beam lines were studied. During the period of two years since then, due to the changes in the circumstances, the design of the lattice was altered. Accordingly, the arrangement of the beam lines and of measuring instruments were largely changed. At this point, the results of discussions in various meetings are described, though they may still be subject to future changes, with due consideration to beam, environment and beam lines required for the design of the measuring instruments: (1) storage ring and synchrotron light beam, (2) requirements on small beam size and beam stability, (3) a synchrotron light experiment facility. (J.P.N.)

  13. An evaluation of safety guidelines to restrict exposure to stray radiofrequency radiation from short-wave diathermy units

    Energy Technology Data Exchange (ETDEWEB)

    Shields, Nora [School of Physiotherapy, La Trobe University, Victoria 3086 (Australia); O' Hare, Neil [Department of Medical Physics and Bioengineering, St James' s Hospital, Dublin 8 (Ireland); Gormley, John [School of Physiotherapy, Trinity College Dublin, Trinity Centre for Health Sciences, St James' s Hospital, Dublin 8 (Ireland)

    2004-07-07

    Short-wave diathermy (SWD), a form of radiofrequency radiation used therapeutically by physiotherapists, may be applied in continuous (CSWD) or pulsed (PSWD) mode using either capacitive or inductive methods. Stray radiation emitted by these units may exceed exposure guidelines close to the equipment. Discrepant guidelines exist on a safe distance from an operating unit for operators and other personnel. Stray electric (E-field) and magnetic (H-field) field strengths from 10 SWD units in six departments were examined using a PMM 8053 meter and two isotropic probes (EP-330, HP-032). A 5 l saline phantom completed the patient circuit. Measurements were recorded in eight directions between 0.5 m and 2 m at hip and eye levels while the units operated at maximum output and data compared to current guidelines. Results found stray fields from capacitive CSWD fell below operator limits at 2 m (E-field 4.8-39.8 V/m; H-field 0.015-0.072 A/m) and at 1 m for inductive CSWD (E-field 0-36 V/m; H-field 0.01-0.065 A/m). Capacitive PSWD fields fell below the limits at 1.5 m (E-field 1.2-19.9 V/m; H-field 0.002-0.045 A/m) and at 1m for inductive PSWD (E-field 0.7-4.0 V/m; H-field 0.009-0.03 A/m). An extra 0.5 m was required before fields fell below the guidelines for other personnel. These results demonstrate, under a worst case scenario, emissions from SWD exceed the guidelines for operators at distances currently recommended as safe. Future guidelines should include recommendations for personnel other than physiotherapists.

  14. An evaluation of safety guidelines to restrict exposure to stray radiofrequency radiation from short-wave diathermy units

    International Nuclear Information System (INIS)

    Shields, Nora; O'Hare, Neil; Gormley, John

    2004-01-01

    Short-wave diathermy (SWD), a form of radiofrequency radiation used therapeutically by physiotherapists, may be applied in continuous (CSWD) or pulsed (PSWD) mode using either capacitive or inductive methods. Stray radiation emitted by these units may exceed exposure guidelines close to the equipment. Discrepant guidelines exist on a safe distance from an operating unit for operators and other personnel. Stray electric (E-field) and magnetic (H-field) field strengths from 10 SWD units in six departments were examined using a PMM 8053 meter and two isotropic probes (EP-330, HP-032). A 5 l saline phantom completed the patient circuit. Measurements were recorded in eight directions between 0.5 m and 2 m at hip and eye levels while the units operated at maximum output and data compared to current guidelines. Results found stray fields from capacitive CSWD fell below operator limits at 2 m (E-field 4.8-39.8 V/m; H-field 0.015-0.072 A/m) and at 1 m for inductive CSWD (E-field 0-36 V/m; H-field 0.01-0.065 A/m). Capacitive PSWD fields fell below the limits at 1.5 m (E-field 1.2-19.9 V/m; H-field 0.002-0.045 A/m) and at 1m for inductive PSWD (E-field 0.7-4.0 V/m; H-field 0.009-0.03 A/m). An extra 0.5 m was required before fields fell below the guidelines for other personnel. These results demonstrate, under a worst case scenario, emissions from SWD exceed the guidelines for operators at distances currently recommended as safe. Future guidelines should include recommendations for personnel other than physiotherapists

  15. Instrumental traditions and theories of light the uses of instruments in the optical revolution

    CERN Document Server

    Chen, Xiang

    2000-01-01

    An analysis of the optical revolution in the context of early 19th century Britain. Far from merely involving the replacement of one optical theory by another, the revolution also involved substantial changes in instruments and the practices that surrounded them. People's judgements about classification, explanation and evaluation were affected by the way they used such optical instruments as spectroscopes, telescopes, polarisers, photometers, gratings, prisms and apertures. There were two instrumental traditions in this historical period, each of which nurtured a body of practice that exemplified how optical instruments should be operated, and especially how the eye should be used. These traditions functioned just like paradigms, shaping perspectives and even world views. Readership: Scholars and graduate students in the history of science, history of instrument, philosophy of science and science studies. Can also be used as a textbook in graduate courses on 19th century physics.

  16. A survey of ectoparasite infestations in stray dogs of Gwang-ju City, Republic of Korea.

    Science.gov (United States)

    Chee, Jeong Hyun; Kwon, Jung Kee; Cho, Ho Seong; Cho, Kyoung Oh; Lee, Yu Jin; Abd El-Aty, A M; Abdel-Aty, A M; Shin, Sung Shik

    2008-03-01

    This study was designed to investigate the incidence of ectoparasite infestation among stray dogs in Gwang-ju City, Republic of Korea. A total of 103 stray dogs collected in the Animal Shelter of Gwang-ju City from November 2003 to August 2005 were investigated in this study. Ectoparasites of one or more genera were detected in 45.6% (47 / 103) of the dogs examined for dermatologic lesions and/or skin scrapings (from 3-5 affected areas). Otodectes cynotis was found to be the most frequent parasite (22.3%, 23 / 103), followed by Sarcoptes scabiei var canis (19.4%, 20 / 103), Ctenocephalides canis (6.8%, 7 / 103), Demodex canis (4.9%, 5 / 103), and Trichodectes canis (1.0%, 1 / 103). Monospecific infestation was found in 83.0% (39 / 47) of the affected dogs, whereas concurrent infestations with 2 or more ectoparasites per animal were found in 17.0% (8 / 47) of the affected dogs. Trichodectes canis is reported for the first time in the Republic of Korea. Dogs less than 1 yr old were more heavily infected than other age groups (66.7%), and small-sized dogs of less than 3 kg body weight were more heavily infected than larger dogs (41.7%).

  17. Measurement of stray radiation within a scanning proton therapy facility: EURADOS WG9 intercomparison exercise of active dosimetry systems

    Czech Academy of Sciences Publication Activity Database

    Farah, J.; Mares, V.; Romero-Exposito, M.; Trinkl, S.; Domingo, C.; Dufek, V.; Klodowska, M.; Kubančák, Ján; Knezevic, Z.; Ploc, Ondřej

    2015-01-01

    Roč. 42, č. 5 (2015), s. 2572-2584 ISSN 0094-2405 Institutional support: RVO:61389005 Keywords : scanning proton therapy * measurement of stray neutrons * spectrometry * ambient dose eyuivalent * intercomparison Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 2.496, year: 2015

  18. Cavity Attenuated Phase Shift (CAPS) Method for Airborne Aerosol Light Extinction Measurement: Instrument Validation and First Results from Field Deployment

    Science.gov (United States)

    Petzold, A.; Perim de Faria, J.; Berg, M.; Bundke, U.; Freedman, A.

    2015-12-01

    Monitoring the direct impact of aerosol particles on climate requires the continuous measurement of aerosol optical parameters like the aerosol extinction coefficient on a regular basis. Remote sensing and ground-based networks are well in place (e.g., AERONET, ACTRIS), whereas the regular in situ measurement of vertical profiles of atmospheric aerosol optical properties remains still an important challenge in quantifying climate change. The European Research Infrastructure IAGOS (In-service Aircraft for a Global Observing System; www.iagos.org) responds to the increasing requests for long-term, routine in situ observational data by using commercial passenger aircraft as measurement platform. However, scientific instrumentation for the measurement of atmospheric constituents requires major modifications before being deployable aboard in-service passenger aircraft. Recently, a compact and robust family of optical instruments based on the cavity attenuated phase shift (CAPS) technique has become available for measuring aerosol light extinction. While this technique was successfully deployed for ground-based atmospheric measurements under various conditions, its suitability for operation aboard aircraft in the free and upper free troposphere still has to be demonstrated. In this work, the modifications of a CAPS PMex instrument for measuring aerosol light extinction on aircraft, the results from subsequent laboratory tests for evaluating the modified instrument prototype, and first results from a field deployment aboard a research aircraft will be covered. In laboratory studies, the instrument showed excellent agreement (deviation CAPS PMex instrument response within 10% deviation. During the field deployment, aerosol extinction coefficients and associated aerosol size distributions have been measured and will be presented as comparison studies between measured and calculated data.

  19. Sulfur Dioxide Analyzer Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Springston, Stephen R. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-05-01

    The Sulfur Dioxide Analyzer measures sulfur dioxide based on absorbance of UV light at one wavelength by SO2 molecules which then decay to a lower energy state by emitting UV light at a longer wavelength. Specifically, SO2 + hυ1 →SO2 *→SO2 + hυ2 The emitted light is proportional to the concentration of SO2 in the optical cell. External communication with the analyzer is available through an Ethernet port configured through the instrument network of the AOS systems. The Model 43i-TLE is part of the i-series of Thermo Scientific instruments. The i-series instruments are designed to interface with external computers through the proprietary Thermo Scientific iPort Software. However, this software is somewhat cumbersome and inflexible. Brookhaven National Laboratory (BNL) has written an interface program in National Instruments LabView that both controls the Model 43i-TLE Analyzer AND queries the unit for all measurement and housekeeping data. The LabView vi (the software program written by BNL) ingests all raw data from the instrument and outputs raw data files in a uniform data format similar to other instruments in the AOS and described more fully in Section 6.0 below.

  20. Integrating Nephelometer Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Uin, J. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-03-01

    The Integrating Nephelometer (Figure 1) is an instrument that measures aerosol light scattering. It measures aerosol optical scattering properties by detecting (with a wide angular integration – from 7 to 170°) the light scattered by the aerosol and subtracting the light scattered by the carrier gas, the instrument walls and the background noise in the detector (zeroing). Zeroing is typically performed for 5 minutes every day at midnight UTC. The scattered light is split into red (700 nm), green (550 nm), and blue (450 nm) wavelengths and captured by three photomultiplier tubes. The instrument can measure total scatter as well as backscatter only (from 90 to 170°) (Heintzenberg and Charlson 1996; Anderson et al. 1996; Anderson and Ogren 1998; TSI 3563 2015) At ARM (Atmospheric Radiation Measurement), two identical Nephelometers are usually run in series with a sample relative humidity (RH) conditioner between them. This is possible because Nephelometer sampling is non-destructive and the sample can be passed on to another instrument. The sample RH conditioner scans through multiple RH values in cycles, treating the sample. This kind of setup allows to study how aerosol particles’ light scattering properties are affected by humidification (Anderson et al. 1996). For historical reasons, the two Nephelometers in this setup are labeled “wet” and “dry”, with the “dry” Nephelometer usually being the one before the conditioner and sampling ambient air (the names are switched for the MAOS measurement site due to the high RH of the ambient air).

  1. Stray dogs as indicators of Toxoplasma gondii distributed in the environment: the first report across an urban-rural gradient in China

    Directory of Open Access Journals (Sweden)

    Yan Chao

    2012-01-01

    Full Text Available Abstract Background Toxoplasmosis is an important parasitic zoonosis caused by the protozoan Toxoplasma gondii that is distributed world-wide and infects a variety of hosts. However, the prevalence of T. gondii in the environment (such as soil, water and food is largely unknown. Due to the technical difficulty in oocyst counting directly, an alternative assay using the serologic status of T. gondii in free-living animals, such as stray or free-living dogs, as an indicator, can be used to evaluate environmental contamination indirectly, as they are exposed to the same risk of infection as humans and other animals. Results In the present study, 231 stray or free-living dogs across an urban-rural gradient were examined to assess the frequency of T. gondii in the environment. Specific antibodies to T. gondii were found in 93 dogs (40.3% by enzyme-linked immunosorbent assay (ELISA, and no statistically significant differences were observed in seroprevalences of T. gondii between urban dogs (38.7% and rural dogs (41% (p > 0.05. Conclusions A high seroprevalence of T. gondii in stray or free-living dogs in the present study indicates that there would be a wide distribution and a constant infection pressure of T. gondii across an urban-rural gradient, and the oocysts of T. gondii in the environment would be an important source of infection for humans and other animals both in urban and rural areas in China.

  2. SU-E-T-598: Parametric Equation for Quick and Reliable Estimate of Stray Neutron Doses in Proton Therapy and Application for Intracranial Tumor Treatments

    Energy Technology Data Exchange (ETDEWEB)

    Bonfrate, A; Farah, J; Sayah, R; Clairand, I [Institut de Radioprotection et de Surete Nucleaire (IRSN), Fontenay-aux-roses (France); De Marzi, L; Delacroix, S [Institut Curie Centre de Protontherapie d Orsay (CPO), Orsay (France); Herault, J [Centre Antoine Lacassagne (CAL) Cyclotron biomedical, Nice (France); Lee, C [National Cancer Institute, Rockville, MD (United States); Bolch, W [Univ Florida, Gainesville, FL (United States)

    2015-06-15

    Purpose: Development of a parametric equation suitable for a daily use in routine clinic to provide estimates of stray neutron doses in proton therapy. Methods: Monte Carlo (MC) calculations using the UF-NCI 1-year-old phantom were exercised to determine the variation of stray neutron doses as a function of irradiation parameters while performing intracranial treatments. This was done by individually changing the proton beam energy, modulation width, collimator aperture and thickness, compensator thickness and the air gap size while their impact on neutron doses were put into a single equation. The variation of neutron doses with distance from the target volume was also included in it. Then, a first step consisted in establishing the fitting coefficients by using 221 learning data which were neutron absorbed doses obtained with MC simulations while a second step consisted in validating the final equation. Results: The variation of stray neutron doses with irradiation parameters were fitted with linear, polynomial, etc. model while a power-law model was used to fit the variation of stray neutron doses with the distance from the target volume. The parametric equation fitted well MC simulations while establishing fitting coefficients as the discrepancies on the estimate of neutron absorbed doses were within 10%. The discrepancy can reach ∼25% for the bladder, the farthest organ from the target volume. Finally, the validation showed results in compliance with MC calculations since the discrepancies were also within 10% for head-and-neck and thoracic organs while they can reach ∼25%, again for pelvic organs. Conclusion: The parametric equation presents promising results and will be validated for other target sites as well as other facilities to go towards a universal method.

  3. Controlling trapping potentials and stray electric fields in a microfabricated ion trap through design and compensation

    International Nuclear Information System (INIS)

    Charles Doret, S; Amini, Jason M; Wright, Kenneth; Volin, Curtis; Killian, Tyler; Ozakin, Arkadas; Denison, Douglas; Hayden, Harley; Pai, C-S; Slusher, Richart E; Harter, Alexa W

    2012-01-01

    Recent advances in quantum information processing with trapped ions have demonstrated the need for new ion trap architectures capable of holding and manipulating chains of many (>10) ions. Here we present the design and detailed characterization of a new linear trap, microfabricated with scalable complementary metal-oxide-semiconductor (CMOS) techniques, that is well-suited to this challenge. Forty-four individually controlled dc electrodes provide the many degrees of freedom required to construct anharmonic potential wells, shuttle ions, merge and split ion chains, precisely tune secular mode frequencies, and adjust the orientation of trap axes. Microfabricated capacitors on dc electrodes suppress radio-frequency pickup and excess micromotion, while a top-level ground layer simplifies modeling of electric fields and protects trap structures underneath. A localized aperture in the substrate provides access to the trapping region from an oven below, permitting deterministic loading of particular isotopic/elemental sequences via species-selective photoionization. The shapes of the aperture and radio-frequency electrodes are optimized to minimize perturbation of the trapping pseudopotential. Laboratory experiments verify simulated potentials and characterize trapping lifetimes, stray electric fields, and ion heating rates, while measurement and cancellation of spatially-varying stray electric fields permits the formation of nearly-equally spaced ion chains. (paper)

  4. Stray field signatures of Néel textured skyrmions in Ir/Fe/Co/Pt multilayer films

    Science.gov (United States)

    Yagil, A.; Almoalem, A.; Soumyanarayanan, Anjan; Tan, Anthony K. C.; Raju, M.; Panagopoulos, C.; Auslaender, O. M.

    2018-05-01

    Skyrmions are nanoscale spin configurations with topological properties that hold great promise for spintronic devices. Here, we establish their Néel texture, helicity, and size in Ir/Fe/Co/Pt multilayer films by constructing a multipole expansion to model their stray field signatures and applying it to magnetic force microscopy images. Furthermore, the demonstrated sensitivity to inhomogeneity in skyrmion properties, coupled with a unique capability to estimate the pinning force governing dynamics, portend broad applicability in the burgeoning field of topological spin textures.

  5. Pulmonary Mycobacterium tuberculosis (Beijing strain infection in a stray dog : clinical communication

    Directory of Open Access Journals (Sweden)

    S.D.C. Parsons

    2008-05-01

    Full Text Available Mycobacterium tuberculosis infection in dogs is rarely reported and has not previously been documented in South Africa. A case of a stray Maltese crossbreed dog with extensive multifocal pulmonary tuberculosis due to M. tuberculosis is described. Pulmonary granulomas in this case were poorly encapsulated and contained large numbers of acid-fast bacteria, highlighting the potential for infected companion animals to excrete the pathogen. Treatment of canine tuberculosis is generally not advised, and for this reason, euthanasia of diseased animals must be advocated in most instances. Physicians and veterinarians must be aware that companion animals with active disease caused by M. tuberculosis could act as a potential source of infection.

  6. Molecular and serological surveillance of canine enteric viruses in stray dogs from Vila do Maio, Cape Verde.

    Science.gov (United States)

    Castanheira, Pedro; Duarte, Ana; Gil, Solange; Cartaxeiro, Clara; Malta, Manuel; Vieira, Sara; Tavares, Luis

    2014-04-23

    Infections caused by canine parvovirus, canine distemper virus and canine coronavirus are an important cause of mortality and morbidity in dogs worldwide. Prior to this study, no information was available concerning the incidence and prevalence of these viruses in Cape Verde archipelago. To provide information regarding the health status of the canine population in Vila do Maio, Maio Island, Cape Verde, 53 rectal swabs were collected from 53 stray dogs during 2010 and 93 rectal swabs and 88 blood samples were collected from 125 stray dogs in 2011. All rectal swabs (2010 n = 53; 2011 n = 93) were analysed for the presence of canine parvovirus, canine distemper virus and canine coronavirus nucleic acids by quantitative PCR methods. Specific antibodies against canine distemper virus and canine parvovirus were also assessed (2011 n = 88).From the 2010 sampling, 43.3% (23/53) were positive for canine parvovirus DNA, 11.3% (6/53) for canine distemper virus RNA and 1.9% (1/53) for canine coronavirus RNA. In 2011, the prevalence values for canine parvovirus and canine coronavirus were quite similar to those from the previous year, respectively 44.1% (41/93), and 1.1% (1/93), but canine distemper virus was not detected in any of the samples analysed (0%, 0/93). Antibodies against canine parvovirus were detected in 71.6% (63/88) blood samples and the seroprevalence found for canine distemper virus was 51.1% (45/88). This study discloses the data obtained in a molecular and serological epidemiological surveillance carried out in urban populations of stray and domestic animals. Virus transmission and spreading occurs easily in large dog populations leading to high mortality rates particularly in unvaccinated susceptible animals. In addition, these animals can act as disease reservoirs for wild animal populations by occasional contact. Identification of susceptible wildlife of Maio Island is of upmost importance to evaluate the risk of pathogen spill over from

  7. Quality assessment of solar UV irradiance measured with array spectroradiometers

    Science.gov (United States)

    Egli, Luca; Gröbner, Julian; Hülsen, Gregor; Bachmann, Luciano; Blumthaler, Mario; Dubard, Jimmy; Khazova, Marina; Kift, Richard; Hoogendijk, Kees; Serrano, Antonio; Smedley, Andrew; Vilaplana, José-Manuel

    2016-04-01

    The reliable quantification of ultraviolet (UV) radiation at the earth's surface requires accurate measurements of spectral global solar UV irradiance in order to determine the UV exposure to human skin and to understand long-term trends in this parameter. Array spectroradiometers (ASRMs) are small, light, robust and cost-effective instruments, and are increasingly used for spectral irradiance measurements. Within the European EMRP ENV03 project "Solar UV", new devices, guidelines and characterization methods have been developed to improve solar UV measurements with ASRMs, and support to the end user community has been provided. In order to assess the quality of 14 end user ASRMs, a solar UV intercomparison was held on the measurement platform of the World Radiation Center (PMOD/WRC) in Davos, Switzerland, from 10 to 17 July 2014. The results of the blind intercomparison revealed that ASRMs, currently used for solar UV measurements, show a large variation in the quality of their solar UV measurements. Most of the instruments overestimate the erythema-weighted UV index - in particular at large solar zenith angles - due to stray light contribution in the UV-B range. The spectral analysis of global solar UV irradiance further supported the finding that the uncertainties in the UV-B range are very large due to stray light contribution in this wavelength range. In summary, the UV index may be detected by some commercially available ASRMs within 5 % compared to the world reference spectroradiometer, if well characterized and calibrated, but only for a limited range of solar zenith angles. Generally, the tested instruments are not yet suitable for solar UV measurements for the entire range between 290 and 400 nm under all atmospheric conditions.

  8. Enabling Junction Temperature Estimation via Collector-Side Thermo-Sensitive Electrical Parameters through Emitter Stray Inductance in High-Power IGBT Modules

    DEFF Research Database (Denmark)

    Luo, Haoze; Li, Wuhua; Iannuzzo, Francesco

    2018-01-01

    This paper proposes the adoption of the inherent emitter stray inductance LeE in high-power insulated gate bipolar transistor (IGBT) modules as a new dynamic thermo-sensitive electrical parameter (d-TSEP). Furthermore, a family of 14 derived dynamic TSEP candidates has been extracted and classified...

  9. UV Blocking Glass: Low Cost Filters for Visible Light Photocatalytic Assessment

    Directory of Open Access Journals (Sweden)

    Charles W. Dunnill

    2014-01-01

    Full Text Available A number of commercially available art protection products have been compared and assessed for their suitability as UV blocking filters in the application of “visible light” photocatalytic research. Many groups claiming visible light photocatalytic success employ filters to block out stray UV radiation in order to justify that their photocatalysts are indeed visible light photocatalysts and not UV light photocatalysts. These filters come in varying degrees of ability and price and many authors fail to correctly characterise their filters in individual papers. The use of effective filters to prevent both false positive and false negative results is important to maintain scientific rigor and create accurate understanding of the subject. The optimum UV filter would have the highest UV blocking properties (<390 nm and simultaneously the highest visible light transmission (390–750 nm. Single and double layers of each of the glass products were assessed as well as laminate products. The conclusions show an inexpensive and highly effective setup for the conduction of visible light photochemistry that should be incorporated as a standard part in any researcher’s work where the claim of visible light activity is made.

  10. Radiation protection measurements with the variance-covariance method in the stray radiation fields from photon and proton therapy facilities

    DEFF Research Database (Denmark)

    Lillhök, J.; Persson, L.; Andersen, Claus E.

    2017-01-01

    , the dose-average lineal energy, the dose-average quality factor and the dose equivalent. The neutron component measured by the detectors at the proton beam was studied through Monte Carlo simulations using the code MCNP6. In the photon beam the stray absorbed dose ranged between 0.3 and 2.4 μGy per monitor...

  11. A Choice Experiment Analysis of the Management of the Stray Dog Population in the UK.

    OpenAIRE

    Siettou, Christina; Fraser, Iain; Fraser, Rob

    2013-01-01

    In this paper we present the results of a pilot study investigating the public’s view on the pet overpopulation problem. The Choice Experiment aims to understand the UK public’s awareness of the issue, its views and its willingness to participate and pay for a reduction in the rate of animals being “put to sleep”. Our preliminary results indicate that the public are willing to pay to keep healthy stray dogs alive for longer in Local Authority kennels beyond the current seven day statutory per...

  12. Some observations on stray magnetic fields and power outputs from short-wave diathermy equipment

    Energy Technology Data Exchange (ETDEWEB)

    Lau, R.W.M.; Dunscombe, P.B.

    1984-04-01

    Recent years have seen increasing interest in the possible hazards arising from the use of nonionizing electromagnetic radiation. Relatively large and potentially hazardous fields are to be found in the vicinity of short-wave and microwave equipment used in physiotherapy departments to produce therapeutic temperature rises. This note reports the results of measurements of the stray magnetic field and power output of a conventional short-wave diathermy unit when applied to tissue-equivalent phantoms. The dependence of these quantities on the variables, i.e. power setting of the unit, capacitor plate size, phantom size and phantom-capacitor plate separation, are discussed.

  13. Identification of feline immunodeficiency virus subtype-B on St. Kitts, West Indies by quantitative PCR.

    Science.gov (United States)

    Kelly, Patrick J; Stocking, Ruey; Gao, Dongya; Phillips, Nikol; Xu, Chuanling; Kaltenboeck, Bernhard; Wang, Chengming

    2011-07-04

    Although antibodies to the feline immunodeficiency virus (FIV) have been detected by SNAP assay in cats from St. Kitts, there have been no molecular studies to further confirm the infection and determine the FIV subtypes present. Total nucleic acids were extracted from EDTA whole blood specimens from 35 cats, followed by quantitative fluorescence resonance energy transfer (FRET) PCR under a six-channel LightCycler 2.0 Instrument with Software version 4.1. Four of 11 stray cats (36 %) but none of 24 owned cats were FIV positive by real-time PCR.  High-resolution melting curve analysis indicated that all four positive cats were infected with FIV subtype-B. This is the first molecular characterization of FIV subtypes on St. Kitts and the results confirm the high prevalence of FIV infection in stray cats on the island.

  14. Prevalence of Echinococcus granulosus taeniasis in stray dogs in the region of Constantine (North-East Algeria).

    Science.gov (United States)

    Kohil, K; Benchikh El Fegoun, M C; Gharbi, M

    2017-10-01

    In North Africa, the domestic dog is regarded as the main reservoir for infection by Echinococcus granulosus of domestic livestock and man. In Algeria, there is very little data on the rate of infestation of dogs, while the prevalence of E. granulosus in the definitive host is a very reliable marker of the potential risk of transmission of cystic tapeworm to humans and livestock. To find out this information, a survey was conducted to assess the prevalence of infection with E. granulosus in stray dogs in the region of Constantine (North-East Algeria). We autopsied and examined 120 stray dogs, 22 (18.3%) of which were infected with E. granulosus, with an average intensity of infestation of 249 worms. The prevalence in the area of survey was evaluated: 15.5% (14/90) and 26.6% (8/30) dogs were parasitized by E. granulosus in urban and rural areas respectively. The influence of age on the rate of infection was very marked. In addition, the appreciation of the prevalence of parasitism by cestodes as a whole showed that 56 (46.6%) animals out of 120 were infected. Facing such a situation of endemic tapeworm parasitism, with a potential risk of transmission to humans, there is an urgent need to take measures to control and break the epidemiological cycles of the parasite.

  15. Early modern mathematical instruments.

    Science.gov (United States)

    Bennett, Jim

    2011-12-01

    In considering the appropriate use of the terms "science" and "scientific instrument," tracing the history of "mathematical instruments" in the early modern period is offered as an illuminating alternative to the historian's natural instinct to follow the guiding lights of originality and innovation, even if the trail transgresses contemporary boundaries. The mathematical instrument was a well-defined category, shared across the academic, artisanal, and commercial aspects of instrumentation, and its narrative from the sixteenth to the eighteenth century was largely independent from other classes of device, in a period when a "scientific" instrument was unheard of.

  16. Integrated Instrumentation for Light-Emitting Polymers Development

    National Research Council Canada - National Science Library

    Jen, Alex

    2000-01-01

    The major objective of this project is to develop an integrated instrumentation that combines the capability of performing spin coating of uniform polymer thin films under an oxygen and moisture free...

  17. Stray dogs and cats as potential sources of soil contamination with zoonotic parasites.

    Science.gov (United States)

    Szwabe, Katarzyna; Blaszkowska, Joanna

    2017-03-22

    The main source of many zoonoses is soil contaminated with feline and canine faeces. Thus, the aim of this study was to estimate the prevalence of intestinal parasites in stray dogs and cats adopted in Lodz shelter (Poland). In total, 163 faecal samples were collected from 95 dogs and 68 cats from 2011 to 2012. The samples were processed by sedimentation techniques using Mini Parasep®SF. Six parasite genera belonging to protozoa, cestoda, and nematoda, were found in dogs, while eight were found in cats. Out of the 163 fecal samples, 37.4% were positive for the presence at least one species of intestinal parasites. The majority of positive dog samples contained eggs from Toxocara and Trichuris genera, and the family Ancylostomatidae, while Toxocara and Taenia eggs, as well as Cystoisospora oocysts, predominated in cat faeces. A significantly higher prevalence of parasites was noted in cats (48.5%) than in dogs (29.5%) (χ2=6.15, P=0.013). The Toxocara genus was the most prevalent parasite in both populations; eggs were found in 27.9% and 16.8% of cats and dogs, respectively. Animals younger than 12 months of age showed higher infection rates with Toxocara, but differences were not statistically significant. The average numbers of Toxocara eggs/gram of faeces in positive puppy and kitten samples were over 5 and 7 times higher than in older dogs and cats, respectively. Mixed infection were found in dogs (5.3%) and cats (8.8%). Cat faeces represent a more important potential source of environmental contamination with zoonotic parasites than dog faeces. Among the detected parasites of stray dogs and cats, Toxocara present an important zoonotic risk for the local human population, especially children.

  18. Countering the stray magnetic field of the CUSP trap by using additional coils

    CERN Document Server

    Thole, Jelle

    2016-01-01

    The ASACUSA experiment at the Antiproton Decelerator (AD) at CERN tries to measure the Hyperfine Structure (HFS) of Antihydrogen (H ̄) using a Rabi spectroscopy set-up. In measuring this HFS it will yield a very precise test of CPT-symmetry. For this set-up to work a homogeneous magnetic field is needed in the cavity where the Hyperfine transition of H ̄ occurs. Due to the stray fields from the CUSP trap, where H ̄ is produced, additional coils are needed to counter these fields. It is found, using COMSOL simulations, that two coils are suitable for this. Leading to a relative standard deviation of the magnetic field of σB/B = 1.06%.

  19. Prevalence and Potential Risk Factors for Bartonella Infection in Tunisian Stray Dogs.

    Science.gov (United States)

    Belkhiria, Jaber; Chomel, Bruno B; Ben Hamida, Taoufik; Kasten, Rickie W; Stuckey, Matthew J; Fleischman, Drew A; Christopher, Mary M; Boulouis, Henri-Jean; Farver, Thomas B

    2017-06-01

    Bartonellae are blood-borne and vector-transmitted pathogens, some are zoonotic, which have been reported in several Mediterranean countries. Transmission from dogs to humans is suspected, but has not been clearly demonstrated. Our objectives were to determine the seroprevalence of Bartonella henselae, Bartonella vinsonii subsp. berkhoffii, Bartonella clarridgeiae, and Bartonella bovis (as a proxy for Candidatus Bartonella merieuxii) in stray dogs from Tunisia, identify the Bartonella species infecting the dogs and evaluate potential risk factors for canine infection. Blood samples were collected between January and November 2013 from 149 dogs in 10 Tunisian governorates covering several climatic zones. Dog-specific and geographic variables were analyzed as potential risk factors for Bartonella spp. seropositivity and PCR-positivity. DNA was extracted from the blood of all dogs and tested by PCR for Bartonella, targeting the ftsZ and rpoB genes. Partial sequencing was performed on PCR-positive dogs. Twenty-nine dogs (19.5%, 95% confidence interval: 14-27.4) were seropositive for one or more Bartonella species, including 17 (11.4%) for B. vinsonii subsp. berkhoffii, 14 (9.4%) for B. henselae, 13 (8.4%) for B. clarridgeiae, and 7 (4.7%) for B. bovis. Statistical analysis revealed a few potential risk factors, mainly dog's age and breed, latitude and average winter temperature. Twenty-two (14.8%) dogs, including 8 of the 29 seropositive dogs, were PCR-positive for Bartonella based on the ftsZ gene, with 18 (81.8%) of these 22 dogs also positive for the rpoB gene. Partial sequencing showed that all PCR-positive dogs were infected with Candidatus B. merieuxii. Dogs from arid regions and regions with cold average winter temperatures were less likely to be PCR-positive than dogs from other climatic zones. The widespread presence of Bartonella spp. infection in Tunisian dogs suggests a role for stray dogs as potential reservoirs of Bartonella species in Tunisia.

  20. Snow and Water Imaging Spectrometer (SWIS): first alignment and characterization results

    Science.gov (United States)

    Bender, Holly A.; Mouroulis, Pantazis; Haag, Justin; Smith, Christopher D.; Van Gorp, Byron E.

    2017-09-01

    The Snow and Water Imaging Spectrometer (SWIS) is a fast, high-uniformity, low-polarization sensitivity imaging spectrometer and telescope system designed for integration on a 6U CubeSat platform. Operating in the 350-1700 nm spectral region with 5.7 nm sampling, SWIS is capable of simultaneously addressing the demanding needs of coastal ocean science and snow and ice monitoring. New key technologies that facilitate the development of this instrument include a linear variable anti-reflection (LVAR) detector coating for stray light management, and a single drive on-board calibration mechanism utilizing a transmissive diffuser for solar calibration. We provide an overview of the SWIS instrument design and potential science applications and describe the instrument assembly and alignment, supported by laboratory measurements.

  1. Low-temperature fabrication and characterization of a symmetric hybrid organic–inorganic slab waveguide for evanescent light microscopy

    Science.gov (United States)

    Agnarsson, Björn; Mapar, Mokhtar; Sjöberg, Mattias; Alizadehheidari, Mohammadreza; Höök, Fredrik

    2018-06-01

    Organic and inorganic solid materials form the building blocks for most of today’s high-technological instruments and devices. However, challenges related to dissimilar material properties have hampered the synthesis of thin-film devices comprised of both organic and inorganic films. We here give a detailed description of a carefully optimized processing protocol used for the construction of a three-layered hybrid organic–inorganic waveguide-chip intended for combined scattering and fluorescence evanescent-wave microscopy in aqueous environments using conventional upright microscopes. An inorganic core layer (SiO2 or Si3N4), embedded symmetrically in an organic cladding layer (CYTOP), aids simple, yet efficient in-coupling of light, and since the organic cladding layer is refractive index matched to water, low stray-light (background) scattering of the propagating light is ensured. Another major advantage is that the inorganic core layer makes the chip compatible with multiple well-established surface functionalization schemes that allows for a broad range of applications, including detection of single lipid vesicles, metallic nanoparticles or cells in complex environments, either label-free—by direct detection of scattered light—or by use of fluorescence excitation and emission. Herein, focus is put on a detailed description of the fabrication of the waveguide-chip, together with a fundamental characterization of its optical properties and performance, particularly in comparison with conventional epi illumination. Quantitative analysis of images obtained from both fluorescence and scattering intensities from surface-immobilized polystyrene nanoparticles in suspensions of different concentrations, revealed enhanced signal-to-noise and signal-to-background ratios for the waveguide illumination compared to the epi-illumination.

  2. A report on the alimentary canal helminthic infestation of stray and pet dogs in Tabriz

    Directory of Open Access Journals (Sweden)

    Y Gharedaghi

    2008-08-01

    Full Text Available From September to December 2007, fecal specimens of 100 stray and pet dogs in Tabriz were examined by saturated salt flotation and Telmann sedimentation methods to determine the prevalence of gastrointestinal helminth infestation. Helminth infestation was encountered in 31 (31% of the fecal samples examined. The eggs of two different cestodes and three different nematodes were identified in the contaminated fecal samples. The helminth eggs found were identified as Taenia hydatigena (4%, Dipylidium caninum (6%, Toxocara canis (10%, Ancylostoma caninum (6% and Trichuris vulpis (5%. No trematoda eggs and nematode larvae were found in this study.

  3. Development of a Novel Spectrophotometer for Biochemical Analyzer Based on Volume Holography Transmissive Grating and Linear CCD

    International Nuclear Information System (INIS)

    Ren Zhong; Liu Guodong; Huang Zhen; Zeng Lvming; Dai Longmin

    2011-01-01

    The classical surface-embossed plane and concave grating are usually used as the diffraction grating in some spectrophotometers. But the minute cracks are produced on the surface of the gratings' grooves, which leads to generate the stray-light and decrease the efficiency of instrument. Therefore, a novel custom-built spectrophotometer for BCA is developed in this paper. Meanwhile, the volume holography transmissive (VHT) grating is used as the diffraction grating in this spectrophotometer. Additionally, a high resolution CCD and data acquisition (DAQ) card with combined the virtual software platform based on LabVIEW are used to design the spectral acquisition and analysis system. Experimental results show that the spectral range and the diffraction efficiency of the spectrophotometer for BCA are greatly increased. The spectral range of the spectrophotometer for BCA can reach 300-1000 nm, its wavelength resolution can reach 1nm. And, it uses the back-splitting-light technology and multi-channel parallel analysis. Compared with other same types, this spectrophotometer has many advantages, such as, higher efficiency, simpler algorithm, higher accuracy, cheaper cost and fewer stray-light and higher imaging quality, etc. Therefore, this spectrophotometer for BCA based on VHT grating will has the greatly potential values in the fields of the biochemical or medical research.

  4. Instrument for fluorescence sensing of circulating cells with diffuse light in mice in vivo.

    Science.gov (United States)

    Zettergren, Eric; Vickers, Dwayne; Runnels, Judith; Murthy, Shashi K; Lin, Charles P; Niedre, Mark

    2012-03-01

    Accurate quantification of circulating cell populations in mice is important in many areas of preclinical biomedical research. Normally, this is done either by extraction and analysis of small blood samples or, more recently, by using microscopy-based in vivo fluorescence flow cytometry. We describe a new technological approach to this problem using detection of diffuse fluorescent light from relatively large blood vessels in vivo. The diffuse fluorescence flow cytometer (DFFC) uses a laser to illuminate a mouse limb and an array of optical fibers coupled to a high-sensitivity photomultiplier tube array operating in photon counting mode to detect weak fluorescence signals from cells. We first demonstrate that the DFFC instrument is capable of detecting fluorescent microspheres and Vybrant-DiD-labeled cells in a custom-made optical flow phantom with similar size, optical properties, linear flow rates, and autofluorescence as a mouse limb. We also present preliminary data demonstrating that the DFFC is capable of detecting circulating cells in nude mice in vivo. In principle, this device would allow interrogation of the whole blood volume of a mouse in minutes, with sensitivity improvement by several orders of magnitude compared to current approaches. © 2012 Society of Photo-Optical Instrumentation Engineers (SPIE).

  5. Experimenting with string musical instruments

    Science.gov (United States)

    LoPresto, Michael C.

    2012-03-01

    What follows are several investigations involving string musical instruments developed for and used in a Science of Sound & Light course. The experiments make use of a guitar, orchestral string instruments and data collection and graphing software. They are designed to provide students with concrete examples of how mathematical formulae, when used in physics, represent reality that can actually be observed, in this case, the operation of string musical instruments.

  6. Measurement and application of bidirectional reflectance distribution function

    Science.gov (United States)

    Liao, Fei; Li, Lin; Lu, Chengwen

    2016-10-01

    When a beam of light with certain intensity and distribution reaches the surface of a material, the distribution of the diffused light is related to the incident angle, the receiving angle, the wavelength of the light and the types of the material. Bidirectional Reflectance Distribution Function (BRDF) is a method to describe this distribution. For an optical system, the optical and mechanical materials' BRDF are unique, and if we want to calculate stray light of the system we should know the correct BRDF data of the whole materials. There are fundamental significances in the area of space remote sensor where BRDF is needed in the precise radiation calibration. It is also important in the military field where BRDF can be used in the object identification and target tracking, etc. In this paper, 11 kinds of aerospace materials' BRDF are measured and more than 310,000 groups of BRDF data are achieved , and also a BRDF database is established in China for the first time. With the BRDF data of the database, we can create the detector model, build the stray light radiation surface model in the stray light analysis software. In this way, the stray radiation on the detector can be calculated correctly.

  7. Experimenting with String Musical Instruments

    Science.gov (United States)

    LoPresto, Michael C.

    2012-01-01

    What follows are several investigations involving string musical instruments developed for and used in a "Science of Sound & Light" course. The experiments make use of a guitar, orchestral string instruments and data collection and graphing software. They are designed to provide students with concrete examples of how mathematical formulae, when…

  8. Design and testing of a magnetic shield for the Thomson scattering photomultiplier tubes in the stray fields of the ERASMUS tokamak

    International Nuclear Information System (INIS)

    Desoppere, E.; Van Oost, G.

    1983-01-01

    A multiple coaxial shield system has been designed for the photomultiplier tubes of the ERASMUS tokamak Thomson scattering diagnostic. A stray field of 75 x 10 -4 T was reduced to 0.01 x 10 -4 T for a field parallel to the tube axis, and to 0.03 x 10 -4 T for a perpendicular field

  9. UVSiPM: A light detector instrument based on a SiPM sensor working in single photon counting

    Energy Technology Data Exchange (ETDEWEB)

    Sottile, G.; Russo, F.; Agnetta, G. [Istituto di Astrofisica Spaziale e Fisica Cosmica di Palermo, IASF-Pa/INAF, Palermo (Italy); Belluso, M.; Billotta, S. [Osservatorio Astrofisico di Catania, OACT/INAF, Catania (Italy); Biondo, B. [Istituto di Astrofisica Spaziale e Fisica Cosmica di Palermo, IASF-Pa/INAF, Palermo (Italy); Bonanno, G. [Osservatorio Astrofisico di Catania, OACT/INAF, Catania (Italy); Catalano, O.; Giarrusso, S. [Istituto di Astrofisica Spaziale e Fisica Cosmica di Palermo, IASF-Pa/INAF, Palermo (Italy); Grillo, A. [Osservatorio Astrofisico di Catania, OACT/INAF, Catania (Italy); Impiombato, D.; La Rosa, G.; Maccarone, M.C.; Mangano, A. [Istituto di Astrofisica Spaziale e Fisica Cosmica di Palermo, IASF-Pa/INAF, Palermo (Italy); Marano, D. [Osservatorio Astrofisico di Catania, OACT/INAF, Catania (Italy); Mineo, T.; Segreto, A.; Strazzeri, E. [Istituto di Astrofisica Spaziale e Fisica Cosmica di Palermo, IASF-Pa/INAF, Palermo (Italy); Timpanaro, M.C. [Osservatorio Astrofisico di Catania, OACT/INAF, Catania (Italy)

    2013-06-15

    UVSiPM is a light detector designed to measure the intensity of electromagnetic radiation in the 320–900 nm wavelength range. It has been developed in the framework of the ASTRI project whose main goal is the design and construction of an end-to-end Small Size class Telescope prototype for the Cherenkov Telescope Array. The UVSiPM instrument is composed by a multipixel Silicon Photo-Multiplier detector unit coupled to an electronic chain working in single photon counting mode with 10 nanosecond double pulse resolution, and by a disk emulator interface card for computer connection. The detector unit of UVSiPM is of the same kind as the ones forming the camera at the focal plane of the ASTRI prototype. Eventually, the UVSiPM instrument can be equipped with a collimator to regulate its angular aperture. UVSiPM, with its peculiar characteristics, will permit to perform several measurements both in lab and on field, allowing the absolute calibration of the ASTRI prototype.

  10. Stray current induced corrosion in lightning rod cables of 525 kV power lines towers: a case study

    OpenAIRE

    Wojcicki, F. R.; Negrisoli, M. E. M.; Franco, C. V.

    2003-01-01

    With the growth of several areas in modem society, the necessity to generate and carry electrical energy to big cities has greatly increased. Cables supported by power towers with galvanized steel foundation usually carry energy. As the foundations are underground they may cause high rates of corrosion. These are usually detected by a conventional potential measurement using a Cu/CuSO4 reference electrode. It is believed that corrosion results from stray currents that f...

  11. Stray current induced corrosion in lightning rod cables of 525 kV power lines towers: a case study

    International Nuclear Information System (INIS)

    Wojcicki, F. R.; Negrisoli, M. E. M.; Franco, C. V.

    2003-01-01

    With the growth of several areas in modern society, the necessity to generate and carry electrical energy to big cities has greatly increased. Cables supported by power towers with galvanized steel foundation usually carry energy. As the foundations are underground they may cause high rates of corrosion. These are usually detected by a conventional potential measurement using a Cu/CuSO 4 reference electrode. It is believed that corrosion results from stray currents that flow through the ground to close the loop between neighboring towers. Stray currents originate in the lightning rod cables of the power line towers, induced by the strong electromagnetic and electric fields of the energized power lines. The intensity and direction of those currents were measured, indicating substantial values of both their AC and DC components. The potential of the tower ground system, measured in the perpendicular direction of the main axis of the power line, was plotted as a function of the distance to the tower base. The results clearly indicated the tendency to corrosive attack in the anodic towers as reflected by the slope of the plot, whereas no signs of corrosion could be found in the reverse slope, confirming the visual inspection of the foundation. The profile of the potential plots could be changed providing the electric insulation of the lightning rod cable. (Author) 8 refs

  12. Endoparasites of Stray Dogs in Mashhad, Khorasan Razavi Province, Northeast Iran with Special Reference to Zoonotic Parasites

    Directory of Open Access Journals (Sweden)

    Amir Adinezadeh

    2013-09-01

    Full Text Available Background: To find out different species of helminthes and blood/tissue proto­zoan parasites of stray dogs and their potential role for transmission of zoonotic species to human in Mashhad, Khorasan Razavi Province, northeast Iran, during 2008-2009.Methods: Totally, 100 stray dogs were selected among Mashhad municipal collection from different sites of the city. Internal organs were examined for any parasites. Helminthes were identified based on morphological characteristics. Smears prepared from peripheral blood as well as liver, spleen and any skin lesion were stained by Giemsa and examined microscopically. Samples obtained from spleen were aseptically cultured in three culture media including NNN, Schneider’s Drosophila (HIMEDIA and RPMI1640 (GIBCO for isolation of Leishmania spp. The titer of anti-Leishmania and anti-Toxoplasma antibodies were measured by direct agglutination test (DAT and indirect fluorescent antibody test (IFAT, respectively.Results: 84% of dogs were infected at least with one species of intestinal helminthes. The species of parasites and rate of infection were as follows: Taenia hydatigena (61%, Dipylidium caninum (46%, Mesocestoides lineatus (19%, Echinococcus granulosus (10%, Toxascaris leonina (53% and Toxocara canis (7%. Anti-Leishmania antibodies were detected by DAT in 8 dogs (8% at 1:320 titers and higher. Forty seven dogs (47% showed anti-Toxoplasma titer at 1:10 and 17 (17% showed titer of ≥1:100. No blood parasites were found in prepared blood smears.Conclusion: The high rate of parasitic infection and presence of zoonotic species

  13. Reduction of ballistic spin scattering in a spin-FET using stray electric fields

    International Nuclear Information System (INIS)

    Nemnes, G A; Manolescu, A; Gudmundsson, V

    2012-01-01

    The quasi-bound states which appear as a consequence of the Rashba spin-orbit (SO) coupling, introduce a strongly irregular behavior of the spin-FET conductance at large Rashba parameter. Moreover, the presence of the bulk inversion asymmetry, i.e. the Dresselhaus SO coupling, may compromise the spin-valve effect even at small values of the Rashba parameter. However, by introducing stray electric fields in addition to the SO couplings, we show that the effect of the SO induced quasi-bound states can be tuned. The oscillations of the spin-resolved conductance become smoother and the control of the spin-FET characteristics becomes possible. For the calculations we employ a multi-channel scattering formalism, based on the R-matrix method extended to spin transport, in the presence of Rashba and Dresselhaus SO couplings.

  14. Evaluation of apical canal shapes produced sequentially during instrumentation with stainless steel hand and Ni-Ti rotary instruments using Micro-computed tomography

    Directory of Open Access Journals (Sweden)

    Woo-Jin Lee

    2011-05-01

    Full Text Available Objectives The purpose of this study was to determine the optimal master apical file size with minimal transportation and optimal efficiency in removing infected dentin. We evaluated the transportation of the canal center and the change in untouched areas after sequential preparation with a #25 to #40 file using 3 different instruments: stainless steel K-type (SS K-file hand file, ProFile and LightSpeed using microcomputed tomography (MCT. Materials and Methods Thirty extracted human mandibular molars with separated orifices and apical foramens on mesial canals were used. Teeth were randomly divided into three groups: SS K-file, Profile, LightSpeed and the root canals were instrumented using corresponding instruments from #20 to #40. All teeth were scanned with MCT before and after instrumentation. Cross section images were used to evaluate canal transportation and untouched area at 1- , 2- , 3- , and 5- mm level from the apex. Data were statistically analyzed according to' repeated nested design'and Mann-Whitney test (p = 0.05. Results In SS K-file group, canal transportation was significantly increased over #30 instrument. In the ProFile group, canal transportation was significantly increased after preparation with the #40 instrument at the 1- and 2- mm levels. LightSpeed group showed better centering ability than ProFile group after preparation with the #40 instrument at the 1 and 2 mm levels. Conclusions SS K-file, Profile, and LightSpeed showed differences in the degree of apical transportation depending on the size of the master apical file.

  15. The legal status of cats in New Zealand: a perspective on the welfare of companion, stray, and feral domestic cats (Felis catus).

    Science.gov (United States)

    Farnworth, Mark J; Dye, Nicholson G; Keown, Natasha

    2010-01-01

    Pinpointing and safeguarding the welfare status of domestic cats is problematic, especially in New Zealand where cats are introduced predators with significant impact on indigenous fauna. Usually the identification of welfare status depends on conservational, legal, and public attitudes that are often contrasting. Cats may rapidly transgress definitions placed on them, confounding attempts to categorize them. In 1 generation, cats can move from a human-dependent state ("stray" or "companion") to wild ("feral"). Often this categorization uses arbitrary behavioral and or situational parameters; consequent treatment and welfare protection for these cats are similarly affected. Terminology used to describe cats is not equitable across research. However, the New Zealand Animal Welfare (Companion Cats) Code of Welfare 2007 seeks to create a new definition of the terms companion, stray, and feral. It distinguishes between cats who live within and without human social constructs. This legislation mandates that cats in human environments or indirectly dependent on humans cannot be classified as feral. Such definitions may prove vital when safeguarding the welfare of free-living domestic cats and cat colonies.

  16. Model of inter-cell interference phenomenon in 10 nm magnetic tunnel junction with perpendicular anisotropy array due to oscillatory stray field from neighboring cells

    Science.gov (United States)

    Ohuchida, Satoshi; Endoh, Tetsuo

    2018-06-01

    In this paper, we propose a new model of inter-cell interference phenomenon in a 10 nm magnetic tunnel junction with perpendicular anisotropy (p-MTJ) array and investigated the interference effect between a program cell and unselected cells due to the oscillatory stray field from neighboring cells by Landau–Lifshitz–Gilbert micromagnetic simulation. We found that interference brings about a switching delay in a program cell and excitation of magnetization precession in unselected cells even when no programing current passes through. The origin of interference is ferromagnetic resonance between neighboring cells. During the interference period, the precession frequency of the program cell is 20.8 GHz, which synchronizes with that of the theoretical precession frequency f = γH eff in unselected cells. The disturbance strength of unselected cells decreased to be inversely proportional to the cube of the distance from the program cell, which is in good agreement with the dependence of stray field on the distance from the program cell calculated by the dipole approximation method.

  17. Report on evaluation of research and development of light-aided instrumentation/control systems. Abstract; Hikari oyo keisoku seigyo system no kenkyu kaihatsu ni kansuru hyoka hokokusho. Gaiyohen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1986-08-01

    This research and development project is aimed at commercialization of the light-aided instrumentation technology systems which safely, stably measure, transmit and control process information including image information, e.g., temperature, flow rates and components at large plants in industrial complexes, in the severe atmospheres in the presence of, e.g., electromagnetic induction and combustible gases. These optical systems need development of light transmitting/receiving devices, various optical devices that constitute the network nodes, and various types of sensors of improved functions and reliability, in addition to development of the techniques required for transmitting large quantities of information on a large scale. This project has attempted to systematically make break-through in the individual elementary techniques, in particular those in the widely diversified technological areas for the advanced devices, and thereby to expand the instrumentation/control technology frontiers. The results of studies on gallium/arsenic crystals, which are prerequisite for photoelectronic integrated circuits as the bases for the light application technology, and processes for producing thereof are highly rated worldwide. It is planned to effectively utilize the total system, constructed at then Nippon Mining's Mizushima Refinery, and thereby to establish the effective instrumentation techniques for commercial plants and to promote commercialization of these results. (NEDO)

  18. Plasmonics for solid-state lighting : enhanced excitation and directional emission of highly efficient light sources

    NARCIS (Netherlands)

    Lozano, G.; Louwers, Davy J.; Rodriguez, S.R.K.; Murai, S.; Jansen, O.T.A.; Verschuuren, M.A.; Gomez Rivas, J.

    2013-01-01

    Light sources based on reliable and energy-efficient light-emitting diodes (LEDs) are instrumental in the development of solid-state lighting (SSL). Most research efforts in SSL have focused on improving both the intrinsic quantum efficiency (QE) and the stability of light emitters. For this reason,

  19. First-light instrument for the 3.6-m Devasthal Optical Telescope: 4Kx4K CCD Imager

    Science.gov (United States)

    Pandey, Shashi Bhushan; Yadav, Rama Kant Singh; Nanjappa, Nandish; Yadav, Shobhit; Reddy, Bheemireddy Krishna; Sahu, Sanjit; Srinivasan, Ramaiyengar

    2018-04-01

    As a part of in-house instrument developmental activity at ARIES, the 4Kx4K CCD Imager is designed and developed as a first-light instrument for the axial port of the 3.6-m Devasthal Optical Telescope (DOT). The f/9 beam of the telescope having a plate-scale of 6.4"/mm is utilized to conduct deeper photom-etry within the central 10' field of view. The pixel size of the blue-enhanced liquid nitrogen cooled STA4150 4Kx4K CCD chip is 15 μm, with options to select gain and speed values to utilize the dynamic range. Using the Imager, it is planned to image the central 6.5'x6.5' field of view of the telescope for various science goals by getting deeper images in several broad-band filters for point sources and objects with low surface brightness. The fully assembled Imager along with automated filter wheels having Bessel UBV RI and SDSS ugriz filters was tested in late 2015 at the axial port of the 3.6-m DOT. This instrument was finally mounted at the axial port of the 3.6-m DOT on 30 March 2016 when the telescope was technically activated jointly by the Prime Ministers of India and Belgium. It is expected to serve as a general purpose multi-band deep imaging instrument for a variety of science goals including studies of cosmic transients, active galaxies, star clusters and optical monitoring of X-ray sources discovered by the newly launched Indian space-mission called ASTROSAT, and follow-up of radio bright objects discovered by the Giant Meterwave Radio Telescope.

  20. The Instrumentation Program for the Thirty Meter Telescope

    OpenAIRE

    Simard, Luc; Crampton, David; Ellerbroek, Brent; Boyer, Corinne

    2012-01-01

    An overview of the current status of the Thirty Meter Telescope (TMT) instrumentation program is presented. Science cases and operational concepts as well as their links to the instruments are continually revisited and updated through a series of workshops and conferences. Work on the three first-light instruments (WFOS IRIS, and IRMS) has made significant progress, and many groups in TMT partner communities are developing future instrument concepts. Other instrument-related subsystems are al...

  1. Message Collision Avoidance Protocols for Detecting Stray Nodes in a Scuba Diving Group Using Ultrasonic Multi-Hop Message Communication

    Directory of Open Access Journals (Sweden)

    Shinya Kaido

    2017-12-01

    Full Text Available Recent years have seen a growing interest in underwater communication and some progress has been made in this area. However, underwater communication is still immature compared with terrestrial communication. A prime reason for this is that the underwater environment is intrinsically not suitable for propagation of electric waves. Instead, ultrasonic waves are mainly used for underwater communication. Since ultrasonic waves cannot provide sufficient communication speed or capacity, they cannot use existing network technologies, which assume use of radio waves. In particular, communication in shallow water is still an uncharted territory. Few communication technologies are employed in environments where people enjoy scuba diving. This paper addresses problems faced by recreational scuba divers. It proposes constructing an ad hoc mesh-shaped network between divers within a group and use ultrasonic waves as transmission media in order to enable the detection of a stray diver. It also proposes a communication protocol in which messages are relayed in multiple hops, and a message collision avoidance method, which is intended to reduce the rate of packet loss caused by message propagation delay. We have implemented the proposed methods in a network simulator, and compared them with an existing communication method that has no message collision avoidance function, in terms of the packet loss rate, the stray driver detection rate, and the rate of the ability to communicate in multiple hops.

  2. What Do They Have That We Don't Have? Local Libraries and Distance Students: Why Do Students Stray and Can We Get Them Back?

    Science.gov (United States)

    Behr, Michele; LaDell-Thomas, Julie

    2014-01-01

    A significant number of distance students report they "stray" from their home universities by using local libraries, despite the fact that distance education librarians work hard to provide customized resources and services tailored to their programs and needs. Are public libraries and special libraries able to meet the research needs of…

  3. Analysis on detection accuracy of binocular photoelectric instrument optical axis parallelism digital calibration instrument

    Science.gov (United States)

    Ying, Jia-ju; Yin, Jian-ling; Wu, Dong-sheng; Liu, Jie; Chen, Yu-dan

    2017-11-01

    Low-light level night vision device and thermal infrared imaging binocular photoelectric instrument are used widely. The maladjustment of binocular instrument ocular axises parallelism will cause the observer the symptom such as dizziness, nausea, when use for a long time. Binocular photoelectric equipment digital calibration instrument is developed for detecting ocular axises parallelism. And the quantitative value of optical axis deviation can be quantitatively measured. As a testing instrument, the precision must be much higher than the standard of test instrument. Analyzes the factors that influence the accuracy of detection. Factors exist in each testing process link which affect the precision of the detecting instrument. They can be divided into two categories, one category is factors which directly affect the position of reticle image, the other category is factors which affect the calculation the center of reticle image. And the Synthesize error is calculated out. And further distribute the errors reasonably to ensure the accuracy of calibration instruments.

  4. Residual stress characterization of steel TIG welds by neutron diffraction and by residual magnetic stray field mappings

    Science.gov (United States)

    Stegemann, Robert; Cabeza, Sandra; Lyamkin, Viktor; Bruno, Giovanni; Pittner, Andreas; Wimpory, Robert; Boin, Mirko; Kreutzbruck, Marc

    2017-03-01

    The residual stress distribution of tungsten inert gas welded S235JRC+C plates was determined by means of neutron diffraction (ND). Large longitudinal residual stresses with maxima around 600 MPa were found. With these results as reference, the evaluation of residual stress with high spatial resolution GMR (giant magneto resistance) sensors was discussed. The experiments performed indicate a correlation between changes in residual stresses (ND) and the normal component of local residual magnetic stray fields (GMR). Spatial variations in the magnetic field strength perpendicular to the welds are in the order of the magnetic field of the earth.

  5. Source-Sink Estimates of Genetic Introgression Show Influence of Hatchery Strays on Wild Chum Salmon Populations in Prince William Sound, Alaska

    OpenAIRE

    Jasper, James R.; Habicht, Christopher; Moffitt, Steve; Brenner, Rich; Marsh, Jennifer; Lewis, Bert; Creelman Fox, Elisabeth; Grauvogel, Zac; Rogers Olive, Serena D.; Grant, W. Stewart

    2013-01-01

    The extent to which stray, hatchery-reared salmon affect wild populations is much debated. Although experiments show that artificial breeding and culture influence the genetics of hatchery salmon, little is known about the interaction between hatchery and wild salmon in a natural setting. Here, we estimated historical and contemporary genetic population structures of chum salmon (Oncorhynchus keta) in Prince William Sound (PWS), Alaska, with 135 single nucleotide polymorphism (SNP) markers. H...

  6. Environment for the instruments

    International Nuclear Information System (INIS)

    Ambro, P.

    1992-01-01

    A properly conditioned AC power supply is necessary for reliable functioning of instruments. Electric mains power is produced primarily for industry, workshops, lighting and household uses. Its quality is adjusted to these uses. In areas sand countries with a fast growing demand for electric power, these requirements are far from being met. Electronic instruments and computers, especially in these countries, need protection against disturbances of the mains supply. A clean and dry environment is needed for reliable functioning and long life of instruments. High humidity, specially at higher temperatures, changes the characteristics of electronic components. Moreover, under these conditions fungal growth causes leakage of currents and corrosion causes poor contacts. The presence of dust enhances these effects. They give rise to malfunction of instruments, particularly of high voltage equipment

  7. Environment for the instruments

    Energy Technology Data Exchange (ETDEWEB)

    Ambro, P

    1993-12-31

    A properly conditioned AC power supply is necessary for reliable functioning of instruments. Electric mains power is produced primarily for industry, workshops, lighting and household uses. Its quality is adjusted to these uses. In areas sand countries with a fast growing demand for electric power, these requirements are far from being met. Electronic instruments and computers, especially in these countries, need protection against disturbances of the mains supply. A clean and dry environment is needed for reliable functioning and long life of instruments. High humidity, specially at higher temperatures, changes the characteristics of electronic components. Moreover, under these conditions fungal growth causes leakage of currents and corrosion causes poor contacts. The presence of dust enhances these effects. They give rise to malfunction of instruments, particularly of high voltage equipment

  8. Design of an ultra-thin near-eye display with geometrical waveguide and freeform optics.

    Science.gov (United States)

    Cheng, Dewen; Wang, Yongtian; Xu, Chen; Song, Weitao; Jin, Guofan

    2014-08-25

    Small thickness and light weight are two important requirements for a see-through near-eye display which are achieved in this paper by using two advanced technologies: geometrical waveguide and freeform optics. A major problem associated with the geometrical waveguide is the stray light which can severely degrade the display quality. The causes and solutions to this problem are thoroughly studied. A mathematical model of the waveguide is established and a non-sequential ray tracing algorithm is developed, which enable us to carefully examine the stray light of the planar waveguide and explore a global searching method to find an optimum design with the least amount of stray light. A projection optics using freeform surfaces on a wedge shaped prism is also designed. The near-eye display integrating the projection optics and the waveguide has a field of view of 28°, an exit pupil diameter of 9.6mm and an exit pupil distance of 20mm. In our final design, the proportion of the stray light energy over the image output energy of the waveguide is reduced to 2%, the modulation transfer function values across the entire field of the eyepiece are above 0.5 at 30 line pairs/mm (lps/mm). A proof-of-concept prototype of the proposed geometrical waveguide near-eye display is developed and demonstrated.

  9. Beamline Design and Instrumentation for the Imaging and Coherence Beamline I13L at the Diamond Light Source

    Science.gov (United States)

    Wagner, U. H.; Pešić, Z. D.; De Fanis, A.; Rau, C.

    2013-03-01

    I13L is a 250 m long hard x-ray beamline (6 keV to 35 keV) at the Diamond Light Source. The beamline comprises of two independent experimental endstations: one for imaging in direct space using x-ray microscopy and one for imaging in reciprocal space using coherent diffraction based imaging techniques. In this paper we will discuss the fundamental design concepts of the beamline and explain their implications for the civil engineering of the endstation building and the beamline instrumentation. For the latter this paper will focus on the beamline mirror systems and monochromators.

  10. Beamline Design and Instrumentation for the Imaging and Coherence Beamline I13L at the Diamond Light Source

    International Nuclear Information System (INIS)

    Wagner, U H; Pešić, Z D; Fanis, A De; Rau, C

    2013-01-01

    I13L is a 250 m long hard x-ray beamline (6 keV to 35 keV) at the Diamond Light Source. The beamline comprises of two independent experimental endstations: one for imaging in direct space using x-ray microscopy and one for imaging in reciprocal space using coherent diffraction based imaging techniques. In this paper we will discuss the fundamental design concepts of the beamline and explain their implications for the civil engineering of the endstation building and the beamline instrumentation. For the latter this paper will focus on the beamline mirror systems and monochromators.

  11. A Novel Low-Cost Instrumentation System for Measuring the Water Content and Apparent Electrical Conductivity of Soils

    Directory of Open Access Journals (Sweden)

    Alan Kardek Rêgo Segundo

    2015-10-01

    Full Text Available The scarcity of drinking water affects various regions of the planet. Although climate change is responsible for the water availability, humanity plays an important role in preserving this precious natural resource. In case of negligence, the likely trend is to increase the demand and the depletion of water resources due to the increasing world population. This paper addresses the development, design and construction of a low cost system for measuring soil volumetric water content (θ, electrical conductivity (σ and temperature (T, in order to optimize the use of water, energy and fertilizer in food production. Different from the existing measurement instruments commonly deployed in these applications, the proposed system uses an auto-balancing bridge circuit as measurement method. The proposed models to estimate θ and σ and correct them in function of T are compared to the ones reported in literature. The final prototype corresponds to a simple circuit connected to a pair of electrode probes, and presents high accuracy, high signal to noise ratio, fast response, and immunity to stray capacitance. The instrument calibration is based on salt solutions with known dielectric constant and electrical conductivity as reference. Experiments measuring clay and sandy soils demonstrate the satisfactory performance of the instrument.

  12. A Novel Low-Cost Instrumentation System for Measuring the Water Content and Apparent Electrical Conductivity of Soils.

    Science.gov (United States)

    Rêgo Segundo, Alan Kardek; Martins, José Helvecio; Monteiro, Paulo Marcos de Barros; de Oliveira, Rubens Alves; Freitas, Gustavo Medeiros

    2015-10-05

    The scarcity of drinking water affects various regions of the planet. Although climate change is responsible for the water availability, humanity plays an important role in preserving this precious natural resource. In case of negligence, the likely trend is to increase the demand and the depletion of water resources due to the increasing world population. This paper addresses the development, design and construction of a low cost system for measuring soil volumetric water content (θ), electrical conductivity (σ) and temperature (T), in order to optimize the use of water, energy and fertilizer in food production. Different from the existing measurement instruments commonly deployed in these applications, the proposed system uses an auto-balancing bridge circuit as measurement method. The proposed models to estimate θ and σ and correct them in function of T are compared to the ones reported in literature. The final prototype corresponds to a simple circuit connected to a pair of electrode probes, and presents high accuracy, high signal to noise ratio, fast response, and immunity to stray capacitance. The instrument calibration is based on salt solutions with known dielectric constant and electrical conductivity as reference. Experiments measuring clay and sandy soils demonstrate the satisfactory performance of the instrument.

  13. Adaptive Lighting

    DEFF Research Database (Denmark)

    Petersen, Kjell Yngve; Søndergaard, Karin; Kongshaug, Jesper

    2015-01-01

    the investigations of lighting scenarios carried out in two test installations: White Cube and White Box. The test installations are discussed as large-scale experiential instruments. In these test installations we examine what could potentially occur when light using LED technology is integrated and distributed......Adaptive Lighting Adaptive lighting is based on a partial automation of the possibilities to adjust the colour tone and brightness levels of light in order to adapt to people’s needs and desires. IT support is key to the technical developments that afford adaptive control systems. The possibilities...... differently into an architectural body. We also examine what might occur when light is dynamic and able to change colour, intensity and direction, and when it is adaptive and can be brought into interaction with its surroundings. In short, what happens to an architectural space when artificial lighting ceases...

  14. Compact and Light-Weight Solar Spaceflight Instrument Designs Utilizing Newly Developed Miniature Free-Standing Zone Plates: EUV Radiometer and Limb-Scanning Monochromator

    Science.gov (United States)

    Seely, J. F.; McMullin, D. R.; Bremer, J.; Chang, C.; Sakdinawat, A.; Jones, A. R.; Vest, R.

    2014-12-01

    Two solar instrument designs are presented that utilize newly developed miniature free-standing zone plates having interconnected Au opaque bars and no support membrane resulting in excellent long-term stability in space. Both instruments are based on a zone plate having 4 mm outer diameter and 1 to 2 degree field of view. The zone plate collects EUV radiation and focuses a narrow bandpass through a pinhole aperture and onto a silicon photodiode detector. As a miniature radiometer, EUV irradiance is accurately determined from the zone plate efficiency and the photodiode responsivity that are calibrated at the NIST SURF synchrotron facility. The EUV radiometer is pointed to the Sun and measures the absolute solar EUV irradiance in high time cadence suitable for solar physics and space weather applications. As a limb-scanning instrument in low earth orbit, a miniature zone-plate monochromator measures the extinction of solar EUV radiation by scattering through the upper atmosphere which is a measure of the variability of the ionosphere. Both instruments are compact and light-weight and are attractive for CubeSats and other missions where resources are extremely limited.

  15. Absorption coefficient instrument for turbid natural waters

    Science.gov (United States)

    Friedman, E.; Cherdak, A.; Poole, L.; Houghton, W.

    1980-01-01

    The paper presents an instrument that directly measures multispectral absorption coefficient of turbid natural water. Attention is given to the design, which is shown to incorporate methods for the compensation of variation in the internal light source intensity, correction of the spectrally dependent nature of the optical elements, and correction for variation in the background light level. In addition, when used in conjunction with a spectrally matched total attenuation instrument, the spectrally dependent scattering coefficient can also be derived. Finally, it is reported that systematic errors associated with multiple scattering have been estimated using Monte Carlo techniques.

  16. Nitrogen dioxide and kerosene-flame soot calibration of photoacoustic instruments for measurement of light absorption by aerosols

    International Nuclear Information System (INIS)

    Arnott, W. Patrick; Moosmu''ller, Hans; Walker, John W.

    2000-01-01

    A nitrogen dioxide calibration method is developed to evaluate the theoretical calibration for a photoacoustic instrument used to measure light absorption by atmospheric aerosols at a laser wavelength of 532.0 nm. This method uses high concentrations of nitrogen dioxide so that both a simple extinction and the photoacoustically obtained absorption measurement may be performed simultaneously. Since Rayleigh scattering is much less than absorption for the gas, the agreement between the extinction and absorption coefficients can be used to evaluate the theoretical calibration, so that the laser gas spectra are not needed. Photoacoustic theory is developed to account for strong absorption of the laser beam power in passage through the resonator. Findings are that the photoacoustic absorption based on heat-balance theory for the instrument compares well with absorption inferred from the extinction measurement, and that both are well within values represented by published spectra of nitrogen dioxide. Photodissociation of nitrogen dioxide limits the calibration method to wavelengths longer than 398 nm. Extinction and absorption at 532 and 1047 nm were measured for kerosene-flame soot to evaluate the calibration method, and the single scattering albedo was found to be 0.31 and 0.20 at these wavelengths, respectively

  17. Prevalence of Toxoplasma gondii antibodies and intestinal parasites in stray cats from Nigde, Turkey

    Directory of Open Access Journals (Sweden)

    Bengi Dündar

    2010-01-01

    Full Text Available The prevalence of antibodies to Toxoplasma gondii was investigated by the Sabin-Feldman Dye test (SFDT in 72 stray cats from Nigde, Turkey. A total of 55 (76.4% of the analysed sera had antibodies to T. gondii. The seropositivity of T. gondii was 77.1% in male and 75.7% in female cats (P>0.05. Faeces of these cats were also examined by zinc sulphate flotation method for the presence of parasite oocysts and eggs of other parasites. Two protozoan parasites were identified as Isospora spp. (12.5% and Eimeria spp. (4.1% in cats. Toxoplasma gondii oocysts were not found in any faecal samples analysed. Two parasitic helminth species were observed: Toxocara cati (15.2% and Toxascaris leonina (20.8%. These common ascarids were recorded for the first time in cats from Nigde.

  18. Light

    CERN Document Server

    Robertson, William C

    2003-01-01

    Why is left right and right left in the mirror? Baffled by the basics of reflection and refraction? Wondering just how the eye works? If you have trouble teaching concepts about light that you don t fully grasp yourself, get help from a book that s both scientifically accurate and entertaining with Light. By combining clear explanations, clever drawings, and activities that use easy-to-find materials, this book covers what science teachers and parents need to know to teach about light with confidence. It uses ray, wave, and particle models of light to explain the basics of reflection and refraction, optical instruments, polarization of light, and interference and diffraction. There s also an entire chapter on how the eye works. Each chapter ends with a Summary and Applications section that reinforces concepts with everyday examples. Whether you need a deeper understanding of how light bends or a good explanation of why the sky is blue, you ll find Light more illuminating and accessible than a college textbook...

  19. Advanced Instrumentation for Ultrafast Science at the LCLS

    Energy Technology Data Exchange (ETDEWEB)

    Berrah, Nora [Univ. of Connecticut, Storrs, CT (United States)

    2015-10-13

    This grant supported a Single Investigator and Small Group Research (SISGR) application to enable multi-user research in Ultrafast Science using the Linac Coherent Light Source (LCLS), the world’s first hard x-ray free electron laser (FEL) which lased for the first time at 1.5 Å on April 20, 2009. The goal of our proposal was to enable a New Era of Science by requesting funds to purchase and build Advanced Instrumentation for Ultrafast Science (AIUS), to utilize the intense, short x-ray pulses produced by the LCLS. The proposed instrumentation will allow peer review selected users to probe the ultrasmall and capture the ultrafast. These tools will expand on the investment already made in the construction of the light source and its instrumentation in both the LCLS and LUSI projects. The AIUS will provide researchers in the AMO, Chemical, Biological and Condensed Matter communities with greater flexibility in defining their scientific agenda at the LCLS. The proposed instrumentation will complement and significantly augment the present AMO instrument (funded through the LCLS project) through detectors and capabilities not included in the initial suite of instrumentation at the facility. We have built all of the instrumentations and they have been utilized by scientists. Please see report attached.

  20. Image processing methods for noise reduction in the TJ-II Thomson Scattering diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Dormido-Canto, S., E-mail: sebas@dia.uned.es [Departamento de Informatica y Automatica, UNED, Madrid 28040 (Spain); Farias, G. [Pontificia Universidad Catolica de Valparaiso, Valparaiso (Chile); Vega, J.; Pastor, I. [Asociacion EURATOM/CIEMAT para Fusion, Madrid 28040 (Spain)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer We describe an approach in order to reduce or mitigate the stray-light on the images and show the exceptional results. Black-Right-Pointing-Pointer We analyze the parameters to take account in the proposed process. Black-Right-Pointing-Pointer We report a simplified exampled in order to explain the proposed process. - Abstract: The Thomsom Scattering diagnostic of the TJ-II stellarator provides temperature and density profiles. The CCD camera acquires images corrupted with noise that, in some cases, can produce unreliable profiles. The main source of noise is the so-called stray-light. In this paper we describe an approach that allows mitigation of the effects that stray-light has on the images: extraction regions with connected-components. In addition, the robustness and effectiveness of the noise reduction technique is validated in two ways: (1) supervised classification and (2) comparison of electron temperature profiles.

  1. Investigation of structure in the modular light pipe component for LED automotive lamp

    Science.gov (United States)

    Chen, Hsi-Chao; Zhou, Yang; Huang, Chien-Sheng; Jhong, Wan-Ling; Cheng, Bo-Wei; Jhang, Jhe-Ming

    2014-09-01

    Light-Emitting Diodes (LEDs) have the advantages of small length, long lifetime, fast response time (μs), low voltage, good mechanical properties and environmental protection. Furthermore, LEDs could replace the halogen lamps to avoid the mercury pollution and economize the use of energy. Therefore, the LEDs could instead of the traditional lamp in the future and became an important light source. The proposal of this study was to investigate the effects of the structure and length of the reflector component for a LED automotive lamp. The novel LED automotive lamp was assembled by several different modularization columnar. The optimized design of the different structure and the length to the reflector was simulated by software TracePro. The design result must met the vehicle regulation of United Nations Economic Commission for Europe (UNECE) such as ECE-R19 etc. The structure of the light pipe could be designed by two steps structure. Then constitute the proper structure and choose different power LED to meet the luminous intensity of the vehicle regulation. The simulation result shows the proper structure and length has the best total luminous flux and a high luminous efficiency for the system. Also, the stray light could meet the vehicle regulation of ECE R19. Finally, the experimental result of the selected structure and length of the light pipe could match the simulation result above 80%.

  2. Inexpensive microwave survey instruments: an evaluation

    International Nuclear Information System (INIS)

    Herman, W.A.; Witters, D.M. Jr.

    1979-11-01

    Instruments were tested. Depending upon the oven modulation and leak location these tests show that the Micromate will yield a warning reading at levels from 0.6 to 1.9 mW/cm 2 , when the effects of modulation sensitivity and polarization ellipticity are considered. It is to be expected, then, that this instrument will yield warning readings even when the oven emission being measured lies well within applicable standards. Its apparent susceptibility to overload damage, however, could decrease its sensitivity with no clue to the user as to what had happened. Given the same considerations and parameters, the tests show that the Guard-Rod will yield a warning reading at levels from 3.7 to 47 mW/cm 2 , depending on which measurement surface is used. This instrument will sometimes yield warnings for oven emissions lying within applicable standards, and sometimes will fail to yield such warnings for emissions 10 times greater than allowable levels. The same considerations show that the Interceptor/Microscan units will light up at levels from as low as 0.7 to 0.8 mW/cm 2 or may require levels of 7 to 9 mW/cm 2 . At levels of 28 to 52 mW/cm 2 or higher, however, the warning LED does not light. If part of the field is cross-polarized, this threshold of extinction may be greater. In any case, there is no apparent way for the user to discern the presence of some potentially hazardous fields, and no way to distinguish such fields from a very low-level field. In summary, instruments of the Interceptor/Microscan design may light up at very low power densities, but fail to light at very high power densities. Clearly, this characteristic is extremely undesirable and potentially dangerous to a user relying on such a device.All of these values assume that the instruments are used in accordance with manufacturer's instructions. Otherwise, results may be worse. Moreover, the range of values given take little or no account of unit-to-unit variation, which may be considerable

  3. Aethalometer™ Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Sedlacek, Arthur J. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-04-01

    The Aethalometer is an instrument that provides a real-time readout of the concentration of “Black” or “Elemental” carbon aerosol particles (BC or E) in an air stream (see Figure 1 and Figure 2). It is a self-contained instrument that measures the rate of change of optical transmission through a spot on a filter where aerosol is being continuously collected and uses the information to calculate the concentration of optically absorbing material in the sampled air stream. The instrument measures the transmitted light intensities through the “sensing” portion of the filter, on which the aerosol spot is being collected, and a “reference” portion of the filter as a check on the stability of the optical source. A mass flowmeter monitors the sample air flow rate. The data from these three measurements is used to determine the mean BC content of the air stream.

  4. The Experience of Dynamic Lighting

    DEFF Research Database (Denmark)

    Petersen, Kjell Yngve; Kristensen, Ole

    2017-01-01

    of daylight openings and the experience of spatial form. However, current developments in LED light sources (light emitting diodes) and adaptive software control systems allow for an enhanced correlation between daylight and artificial lighting, where the variations of the daylight are dynamically...... supplemented by variations in the artificial lighting. The suggestion is to develop a particular type of Observational Instrument that situates detailed experiential investigations into the design potentials of integration of natural and artificial lighting, and thereby to enable differentiated dynamic...

  5. Scaled-model guidelines for formation-flying solar coronagraph missions.

    Science.gov (United States)

    Landini, Federico; Romoli, Marco; Baccani, Cristian; Focardi, Mauro; Pancrazzi, Maurizio; Galano, Damien; Kirschner, Volker

    2016-02-15

    Stray light suppression is the main concern in designing a solar coronagraph. The main contribution to the stray light for an externally occulted space-borne solar coronagraph is the light diffracted by the occulter and scattered by the optics. It is mandatory to carefully evaluate the diffraction generated by an external occulter and the impact that it has on the stray light signal on the focal plane. The scientific need for observations to cover a large portion of the heliosphere with an inner field of view as close as possible to the photospheric limb supports the ambition of launching formation-flying giant solar coronagraphs. Their dimension prevents the possibility of replicating the flight geometry in a clean laboratory environment, and the strong need for a scaled model is thus envisaged. The problem of scaling a coronagraph has already been faced for exoplanets, for a single point source on axis at infinity. We face the problem here by adopting an original approach and by introducing the scaling of the solar disk as an extended source.

  6. Optimization of the occulter for the Solar Orbiter/METIS coronagraph

    Science.gov (United States)

    Landini, Federico; Vivès, Sébastien; Romoli, Marco; Guillon, Christophe; Pancrazzi, Maurizio; Escolle, Clement; Focardi, Mauro; Antonucci, Ester; Fineschi, Silvano; Naletto, Giampiero; Nicolini, Gianalfredo; Nicolosi, Piergiorgio; Spadaro, Daniele

    2012-09-01

    METIS (Multi Element Telescope for Imaging and Spectroscopy investigation), selected to fly aboard the Solar Orbiter ESA/NASA mission, is conceived to perform imaging (in visible, UV and EUV) and spectroscopy (in EUV) of the solar corona, by means of an integrated instrument suite located on a single optical bench and sharing the same aperture on the satellite heat shield. As every coronagraph, METIS is highly demanding in terms of stray light suppression. Coronagraphs history teaches that a particular attention must be dedicated to the occulter optimization. The METIS occulting system is of particular interest due to its innovative concept. In order to meet the strict thermal requirements of Solar Orbiter, METIS optical design has been optimized by moving the entrance pupil at the level of the external occulter on the S/C thermal shield, thus reducing the size of the external aperture. The scheme is based on an inverted external-occulter (IEO). The IEO consists of a circular aperture on the Solar Orbiter thermal shield. A spherical mirror rejects back the disk-light through the IEO. A breadboard of the occulting assembly (BOA) has been manufactured in order to perform stray light tests in front of two solar simulators (in Marseille, France and in Torino, Italy). A first measurement campaign has been carried on at the Laboratoire d'Astrophysique de Marseille. In this paper we describe the BOA design, the laboratory set-up and the preliminary results.

  7. Spectroelectrochemical Instrument Measures TOC

    Science.gov (United States)

    Kounaves, Sam

    2011-01-01

    A spectroelectrochemical instrument has been developed for measuring the total organic carbon (TOC) content of an aqueous solution. Measurements of TOC are frequently performed in environmental, clinical, and industrial settings. Until now, techniques for performing such measurements have included, various ly, the use of hazardous reagents, ultraviolet light, or ovens, to promote reactions in which the carbon contents are oxidized. The instrument now being developed is intended to be a safer, more economical means of oxidizing organic carbon and determining the TOC levels of aqueous solutions and for providing a low power/mass unit for use in planetary missions.

  8. Cavity Attenuated Phase Shift (CAPS) Monitor Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Sedlacek, Arthur J. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-04-01

    The CAPS PMex monitor is a cavity attenuated phase shift extinction instrument. It operates as an optical extinction spectrometer, using a visible-light-emitting diode (LED) as the light source, a sample cell incorporating two high-reflectivity mirrors centered at the wavelength of the LED, and a vacuum photodiode detector. Its efficacy is based on the fact that aerosols are broadband scatterers and absorbers of light.

  9. Seismic Instrumentation Placement Recommendations Report

    International Nuclear Information System (INIS)

    Kennedy, W.N.

    1998-01-01

    DOE Order 420.1, ''Facility Safety'', requires that facilities or sites with hazardous materials be provided with instrumentation or other means to detect and record the occurrences and severity of seismic events. These requirements assure that necessary records are available after an earthquake for evaluation purposes and to supplement other data to justify a facility restart or curtailing plant operations after an earthquake. This report documents the basis for the selection of Savannah River Site areas and existing facilities to be instrumented. The need to install instrumentation in new facilities such as the Actinide Packaging and Storage Facility, Commercial Light Water Reactor Tritium Extraction Facility and the Accelerator Production of Tritium Facility will be assessed separately

  10. THE COSMIC INFRARED BACKGROUND EXPERIMENT (CIBER): THE WIDE-FIELD IMAGERS

    Energy Technology Data Exchange (ETDEWEB)

    Bock, J.; Battle, J. [Jet Propulsion Laboratory (JPL), National Aeronautics and Space Administration (NASA), Pasadena, CA 91109 (United States); Sullivan, I. [Department of Physics, University of Washington, Seattle, WA 98195 (United States); Arai, T.; Matsumoto, T.; Matsuura, S.; Tsumura, K. [Department of Space Astronomy and Astrophysics, Institute of Space and Astronautical Science (ISAS), Japan Aerospace Exploration Agency (JAXA), Sagamihara, Kanagawa 252-5210 (Japan); Cooray, A.; Mitchell-Wynne, K.; Smidt, J. [Center for Cosmology, University of California, Irvine, CA 92697 (United States); Hristov, V.; Lam, A. C.; Levenson, L. R.; Mason, P. [Department of Physics, Mathematics and Astronomy, California Institute of Technology, Pasadena, CA 91125 (United States); Keating, B.; Renbarger, T. [Department of Physics, University of California, San Diego, San Diego, CA 92093 (United States); Kim, M. G. [Department of Physics and Astronomy, Seoul National University, Seoul 151-742 (Korea, Republic of); Lee, D. H. [Institute of Astronomy and Astrophysics, Academia Sinica, National Taiwan University, Taipei 10617, Taiwan (China); Nam, U. W. [Korea Astronomy and Space Science Institute (KASI), Daejeon 305-348 (Korea, Republic of); Suzuki, K. [Instrument Development Group of Technical Center, Nagoya University, Nagoya, Aichi 464-8602 (Japan); and others

    2013-08-15

    We have developed and characterized an imaging instrument to measure the spatial properties of the diffuse near-infrared extragalactic background light (EBL) in a search for fluctuations from z > 6 galaxies during the epoch of reionization. The instrument is part of the Cosmic Infrared Background Experiment (CIBER), designed to observe the EBL above Earth's atmosphere during a suborbital sounding rocket flight. The imaging instrument incorporates a 2 Degree-Sign Multiplication-Sign 2 Degree-Sign field of view to measure fluctuations over the predicted peak of the spatial power spectrum at 10 arcmin, and 7'' Multiplication-Sign 7'' pixels, to remove lower redshift galaxies to a depth sufficient to reduce the low-redshift galaxy clustering foreground below instrumental sensitivity. The imaging instrument employs two cameras with {Delta}{lambda}/{lambda} {approx} 0.5 bandpasses centered at 1.1 {mu}m and 1.6 {mu}m to spectrally discriminate reionization extragalactic background fluctuations from local foreground fluctuations. CIBER operates at wavelengths where the electromagnetic spectrum of the reionization extragalactic background is thought to peak, and complements fluctuation measurements by AKARI and Spitzer at longer wavelengths. We have characterized the instrument in the laboratory, including measurements of the sensitivity, flat-field response, stray light performance, and noise properties. Several modifications were made to the instrument following a first flight in 2009 February. The instrument performed to specifications in three subsequent flights, and the scientific data are now being analyzed.

  11. Specific feature of magnetooptical images of stray fields of magnets of various geometrical shapes

    Science.gov (United States)

    Ivanov, V. E.; Koveshnikov, A. V.; Andreev, S. V.

    2017-08-01

    Specific features of magnetooptical images (MOIs) of stray fields near the faces of prismatic hard magnetic elements have been studied. Attention has primarily been focused on MOIs of fields near faces oriented perpendicular to the magnetic moment of hard magnetic elements. With regard to the polar sensitivity, MOIs have practically uniform brightness and geometrically they coincide with the figures of the bases of the elements. With regard to longitudinal sensitivity, MOIs consist of several sectors, the number of which is determined by the number of angles of the image. Each angle is divided by the bisectrix into two sectors of different brightnesses; therefore, the MOI of a triangular magnet consists of three sectors. A rectangle consists of four sectors separated by the bisectrices of the interior angles. In all types of figures, these lines converge at the center of the figure and form a singular point of the source or sink type.

  12. A simple, high performance Thomson scattering diagnostic for high temperature plasma research

    International Nuclear Information System (INIS)

    Hartog, D.J.D.; Cekic, M.

    1994-02-01

    This Thomson scattering diagnostic is used to measure the electron temperature and density of the plasma in the MST reversed-field pinch, a magnetic confinement fusion research device. This diagnostic system is unique for its type in that it combines high performance with simple design and low cost components. In the design of this instrument, careful attention was given to the suppression of stray laser line light with simple and effective beam dumps, viewing dumps, aperatures, and a holographic edge filter. This allows the use of a single grating monochromator for dispersion of the Thomson scattered spectrum onto the microchannel plate detector. Alignment and calibration procedures for the laser beam delivery system, the scattered light collection system, and the spectrometer and detector are described. A sample Thomson scattered spectrum illustrates typical data

  13. Development of a near-infrared spectroscopy instrument for applications in urology.

    Science.gov (United States)

    Macnab, Andrew J; Stothers, Lynn

    2008-10-01

    Near infrared spectroscopy (NIRS) is an established technology using photons of light in the near infrared spectrum to monitor changes in tissue of naturally occurring chromophores, including oxygenated and deoxygenated hemoglobin. Technology and methodology have been validated for measurement of a range of physiologic parameters. NIRS has been applied successfully in urology research; however current instruments are designed principally for brain and muscle study. To describe development of a NIRS instrument specifically designed for monitoring changes in chromophore concentration in the bladder detrusor in real time, to facilitate research to establish the role of this non-invasive technology in the evaluation of patients with voiding dysfunction The portable continuous wave NIRS instrument has a 3 laser diode light source (785, 808 and 830 nanometers), fiber optic cables for light transmission, a self adhesive patient interface patch with an emitter and sensor, and software to detect the difference between the light transmitted and received by the instrument. Software incorporated auto-attenuates the optical signals and converts raw optical data into chromophore concentrations displayed graphically. The prototype was designed, tested, and iteratively developed to achieve optimal suprapubic transcutaneous monitoring of the detrusor in human subjects during bladder filling and emptying. Evaluation with simultaneous invasive urodynamic measurement in men and women indicates good specificity and sensitivity of NIRS chromophore concentration changes by receiver operator curve analysis, and correlation between NIRS data and urodynamic pressures. Urological monitoring with this NIRS instrument is feasible and generates data of potential diagnostic value.

  14. Source-sink estimates of genetic introgression show influence of hatchery strays on wild chum salmon populations in Prince William Sound, Alaska.

    Directory of Open Access Journals (Sweden)

    James R Jasper

    Full Text Available The extent to which stray, hatchery-reared salmon affect wild populations is much debated. Although experiments show that artificial breeding and culture influence the genetics of hatchery salmon, little is known about the interaction between hatchery and wild salmon in a natural setting. Here, we estimated historical and contemporary genetic population structures of chum salmon (Oncorhynchus keta in Prince William Sound (PWS, Alaska, with 135 single nucleotide polymorphism (SNP markers. Historical population structure was inferred from the analysis of DNA from fish scales, which had been archived since the late 1960's for several populations in PWS. Parallel analyses with microsatellites and a test based on Hardy-Weinberg proportions showed that about 50% of the fish-scale DNA was cross-contaminated with DNA from other fish. These samples were removed from the analysis. We used a novel application of the classical source-sink model to compare SNP allele frequencies in these archived fish-scales (1964-1982 with frequencies in contemporary samples (2008-2010 and found a temporal shift toward hatchery allele frequencies in some wild populations. Other populations showed markedly less introgression, despite moderate amounts of hatchery straying. The extent of introgression may reflect similarities in spawning time and life-history traits between hatchery and wild fish, or the degree that hybrids return to a natal spawning area. The source-sink model is a powerful means of detecting low levels of introgression over several generations.

  15. Front lighted optical tooling method and apparatus

    International Nuclear Information System (INIS)

    Stone, W. J.

    1985-01-01

    An optical tooling method and apparatus uses a front lighted shadowgraphic technique to enhance visual contrast of reflected light. The apparatus includes an optical assembly including a fiducial mark, such as cross hairs, reflecting polarized light with a first polarization, a polarizing element backing the fiducial mark and a reflective surface backing the polarizing element for reflecting polarized light bypassing the fiducial mark and traveling through the polarizing element. The light reflected by the reflecting surface is directed through a second pass of the polarizing element toward the frontal direction with a polarization differing from the polarization of the light reflected by the fiducial mark. When used as a tooling target, the optical assembly may be mounted directly to a reference surface or may be secured in a mounting, such as a magnetic mounting. The optical assembly may also be mounted in a plane defining structure and used as a spherometer in conjunction with an optical depth measuring instrument. A method of measuring a radius of curvature of an unknown surface includes positioning the spherometer on a surface between the surface and a depth measuring optical instrument. As the spherometer is frontally illuminated, the distance from the depth measuring instrument to the fiducial mark and the underlying surface are alternately measured and the difference in these measurements is used as the sagittal height to calculate a radius of curvature

  16. Double-grating polychromator for laser-aided plasma diagnostics

    International Nuclear Information System (INIS)

    Mukhin, E.E.; Razdobarin, G.T.; Semenov, V.V.; Shilnikov, A.N.; Sukhanov, V.L.; Tolstjakov, S.Yu.; Kochergin, M.M.; Mihailovskij, Yu.K.; Bakh, L.I.

    2004-01-01

    A wide bandpass double-grating polychromator with high rejection and high transmission has been designed and manufactured for laser-aided plasma diagnostics. The special mount utilizes subtractive dispersion in the second stage of the double polychromator such that the larger dispersion of the second stage is reduced by that of the first stage. This affects the intensity of the stray light background at the laser wavelength. The background at the edge of the laser line was measured at 10 -5 of the light incident on the input slit. At the short end of the 200 nm bandpass, the stray light relative intensity approached 10 -7

  17. Comparison of Two Methodologies for Calibrating Satellite Instruments in the Visible and Near-Infrared

    Science.gov (United States)

    Barnes, Robert A.; Brown, Steven W.; Lykke, Keith R.; Guenther, Bruce; Butler, James J.; Schwarting, Thomas; Turpie, Kevin; Moyer, David; DeLuccia, Frank; Moeller, Christopher

    2015-01-01

    Traditionally, satellite instruments that measure Earth-reflected solar radiation in the visible and near infrared wavelength regions have been calibrated for radiance responsivity in a two-step method. In the first step, the relative spectral response (RSR) of the instrument is determined using a nearly monochromatic light source such as a lamp-illuminated monochromator. These sources do not typically fill the field-of-view of the instrument nor act as calibrated sources of light. Consequently, they only provide a relative (not absolute) spectral response for the instrument. In the second step, the instrument views a calibrated source of broadband light, such as a lamp-illuminated integrating sphere. The RSR and the sphere absolute spectral radiance are combined to determine the absolute spectral radiance responsivity (ASR) of the instrument. More recently, a full-aperture absolute calibration approach using widely tunable monochromatic lasers has been developed. Using these sources, the ASR of an instrument can be determined in a single step on a wavelength-by-wavelength basis. From these monochromatic ASRs, the responses of the instrument bands to broadband radiance sources can be calculated directly, eliminating the need for calibrated broadband light sources such as lamp-illuminated integrating spheres. In this work, the traditional broadband source-based calibration of the Suomi National Preparatory Project (SNPP) Visible Infrared Imaging Radiometer Suite (VIIRS) sensor is compared with the laser-based calibration of the sensor. Finally, the impact of the new full-aperture laser-based calibration approach on the on-orbit performance of the sensor is considered.

  18. Cellular telephone-based radiation detection instrument

    Science.gov (United States)

    Craig, William W [Pittsburg, CA; Labov, Simon E [Berkeley, CA

    2011-06-14

    A network of radiation detection instruments, each having a small solid state radiation sensor module integrated into a cellular phone for providing radiation detection data and analysis directly to a user. The sensor module includes a solid-state crystal bonded to an ASIC readout providing a low cost, low power, light weight compact instrument to detect and measure radiation energies in the local ambient radiation field. In particular, the photon energy, time of event, and location of the detection instrument at the time of detection is recorded for real time transmission to a central data collection/analysis system. The collected data from the entire network of radiation detection instruments are combined by intelligent correlation/analysis algorithms which map the background radiation and detect, identify and track radiation anomalies in the region.

  19. CARMENES instrument overview

    Science.gov (United States)

    Quirrenbach, A.; Amado, P. J.; Caballero, J. A.; Mundt, R.; Reiners, A.; Ribas, I.; Seifert, W.; Abril, M.; Aceituno, J.; Alonso-Floriano, F. J.; Ammler-von Eiff, M.; Antona Jiménez, R.; Anwand-Heerwart, H.; Azzaro, M.; Bauer, F.; Barrado, D.; Becerril, S.; Béjar, V. J. S.; Benítez, D.; Berdiñas, Z. M.; Cárdenas, M. C.; Casal, E.; Claret, A.; Colomé, J.; Cortés-Contreras, M.; Czesla, S.; Doellinger, M.; Dreizler, S.; Feiz, C.; Fernández, M.; Galadí, D.; Gálvez-Ortiz, M. C.; García-Piquer, A.; García-Vargas, M. L.; Garrido, R.; Gesa, L.; Gómez Galera, V.; González Álvarez, E.; González Hernández, J. I.; Grözinger, U.; Guàrdia, J.; Guenther, E. W.; de Guindos, E.; Gutiérrez-Soto, J.; Hagen, H.-J.; Hatzes, A. P.; Hauschildt, P. H.; Helmling, J.; Henning, T.; Hermann, D.; Hernández Castaño, L.; Herrero, E.; Hidalgo, D.; Holgado, G.; Huber, A.; Huber, K. F.; Jeffers, S.; Joergens, V.; de Juan, E.; Kehr, M.; Klein, R.; Kürster, M.; Lamert, A.; Lalitha, S.; Laun, W.; Lemke, U.; Lenzen, R.; López del Fresno, Mauro; López Martí, B.; López-Santiago, J.; Mall, U.; Mandel, H.; Martín, E. L.; Martín-Ruiz, S.; Martínez-Rodríguez, H.; Marvin, C. J.; Mathar, R. J.; Mirabet, E.; Montes, D.; Morales Muñoz, R.; Moya, A.; Naranjo, V.; Ofir, A.; Oreiro, R.; Pallé, E.; Panduro, J.; Passegger, V.-M.; Pérez-Calpena, A.; Pérez Medialdea, D.; Perger, M.; Pluto, M.; Ramón, A.; Rebolo, R.; Redondo, P.; Reffert, S.; Reinhardt, S.; Rhode, P.; Rix, H.-W.; Rodler, F.; Rodríguez, E.; Rodríguez-López, C.; Rodríguez-Pérez, E.; Rohloff, R.-R.; Rosich, A.; Sánchez-Blanco, E.; Sánchez Carrasco, M. A.; Sanz-Forcada, J.; Sarmiento, L. F.; Schäfer, S.; Schiller, J.; Schmidt, C.; Schmitt, J. H. M. M.; Solano, E.; Stahl, O.; Storz, C.; Stürmer, J.; Suárez, J. C.; Ulbrich, R. G.; Veredas, G.; Wagner, K.; Winkler, J.; Zapatero Osorio, M. R.; Zechmeister, M.; Abellán de Paco, F. J.; Anglada-Escudé, G.; del Burgo, C.; Klutsch, A.; Lizon, J. L.; López-Morales, M.; Morales, J. C.; Perryman, M. A. C.; Tulloch, S. M.; Xu, W.

    2014-07-01

    This paper gives an overview of the CARMENES instrument and of the survey that will be carried out with it during the first years of operation. CARMENES (Calar Alto high-Resolution search for M dwarfs with Exoearths with Near-infrared and optical Echelle Spectrographs) is a next-generation radial-velocity instrument under construction for the 3.5m telescope at the Calar Alto Observatory by a consortium of eleven Spanish and German institutions. The scientific goal of the project is conducting a 600-night exoplanet survey targeting ~ 300 M dwarfs with the completed instrument. The CARMENES instrument consists of two separate echelle spectrographs covering the wavelength range from 0.55 to 1.7 μm at a spectral resolution of R = 82,000, fed by fibers from the Cassegrain focus of the telescope. The spectrographs are housed in vacuum tanks providing the temperature-stabilized environments necessary to enable a 1 m/s radial velocity precision employing a simultaneous calibration with an emission-line lamp or with a Fabry-Perot etalon. For mid-M to late-M spectral types, the wavelength range around 1.0 μm (Y band) is the most important wavelength region for radial velocity work. Therefore, the efficiency of CARMENES has been optimized in this range. The CARMENES instrument consists of two spectrographs, one equipped with a 4k x 4k pixel CCD for the range 0.55 - 1.05 μm, and one with two 2k x 2k pixel HgCdTe detectors for the range from 0.95 - 1.7μm. Each spectrograph will be coupled to the 3.5m telescope with two optical fibers, one for the target, and one for calibration light. The front end contains a dichroic beam splitter and an atmospheric dispersion corrector, to feed the light into the fibers leading to the spectrographs. Guiding is performed with a separate camera; on-axis as well as off-axis guiding modes are implemented. Fibers with octagonal cross-section are employed to ensure good stability of the output in the presence of residual guiding errors. The

  20. Analysis of the accuracy of different laboratory methods for the diagnosis of intestinal parasites from stray and domiciled cats (Felis catus domesticus in Goiânia, Goiás, Brazil

    Directory of Open Access Journals (Sweden)

    Jaqueline Ataíde Silva Lima

    2018-02-01

    Full Text Available Abstract Cats are carriers of zoonotic agents to humans, including intestinal parasites. The purpose of this study was to analyze the accuracy of different laboratory methods for the diagnosis of intestinal parasites. Fecal samples were processed by the Willis, Sheather, Faust and Hoffman-Janer-Pons-Lutz (HJPL methods. Accuracy analysis was performed determining the sensitivity, specificity, positive and negative predictive value and Kappa. A total of 149 fecal samples were collected, 65 from stray cats and 84 from domiciled cats. The prevalence of intestinal parasites in stray cats was 60% while in domiciled cats it was 17%. In the analysis of accuracy, the techniques that showed the greatest accuracy for Ancylostomids were Willis and Faust, for Cystoisospora spp. Sheather with Faust or HPJL, and Toxoplasma gondii/Hammondia hammondi the association between Willis and Faust. Therefore, for a reliable evaluation of the prevalence of intestinal parasites, at least two different techniques should be used in parasitological exams of feces.

  1. Deep-learnt classification of light curves

    DEFF Research Database (Denmark)

    Mahabal, Ashish; Gieseke, Fabian; Pai, Akshay Sadananda Uppinakudru

    2017-01-01

    Astronomy light curves are sparse, gappy, and heteroscedastic. As a result standard time series methods regularly used for financial and similar datasets are of little help and astronomers are usually left to their own instruments and techniques to classify light curves. A common approach is to d...

  2. Instrument intercomparison in the pulsed neutron fieldsat the CERN HiRadMat facility

    CERN Document Server

    Aza, E; Cassell, C; Charitonidis, N; Harrouch, E; Manessi, G P; Pangallo, M; Perrin, D; Samara, E; Silari, M

    2014-01-01

    An intercomparison of the performances of active neutron detectors was carried out in pulsed neutron fi elds in the new HiRadMat facility at CERN. Five detectors were employed: four of them (two ionization chambers and two rem counters) are routinely employed in the CERN radiation monitoring system, while the fi fth is a novel instrument, called LUPIN, speci fi cally conceived for applications in pulsed neutron fi elds. The measurements were performed in the stray fi eld generated by a proton beam of very short duration with momentum of 440 GeV/c impinging on a dump. The beam intensity was steadily increased during the experiment by more than three orders of magnitude, with an H*(10) due to neutrons at the detector reference positions varying between a few nSv per burst and a few m Sv per burst, whereas the gamma contribution to the total H*(10) was negligible. The aim of the experiment was to evaluate the linearity of the detector response in extreme pulsed conditions as a function of the neutron burst in- t...

  3. A simple and fast physics-based analytical method to calculate therapeutic and stray doses from external beam, megavoltage x-ray therapy.

    Science.gov (United States)

    Jagetic, Lydia J; Newhauser, Wayne D

    2015-06-21

    State-of-the-art radiotherapy treatment planning systems provide reliable estimates of the therapeutic radiation but are known to underestimate or neglect the stray radiation exposures. Most commonly, stray radiation exposures are reconstructed using empirical formulas or lookup tables. The purpose of this study was to develop the basic physics of a model capable of calculating the total absorbed dose both inside and outside of the therapeutic radiation beam for external beam photon therapy. The model was developed using measurements of total absorbed dose in a water-box phantom from a 6 MV medical linear accelerator to calculate dose profiles in both the in-plane and cross-plane direction for a variety of square field sizes and depths in water. The water-box phantom facilitated development of the basic physical aspects of the model. RMS discrepancies between measured and calculated total absorbed dose values in water were less than 9.3% for all fields studied. Computation times for 10 million dose points within a homogeneous phantom were approximately 4 min. These results suggest that the basic physics of the model are sufficiently simple, fast, and accurate to serve as a foundation for a variety of clinical and research applications, some of which may require that the model be extended or simplified based on the needs of the user. A potentially important advantage of a physics-based approach is that the model is more readily adaptable to a wide variety of treatment units and treatment techniques than with empirical models.

  4. Analysis of stray grain formation in single crystal CMSX-4 superalloy; Analyse der Bildung von Fehlkoernern in einer einkristallinen CMSX-4-Superlegierung

    Energy Technology Data Exchange (ETDEWEB)

    Chmiela, Bartosz; Sozanska, Maria; Cwajna, Jan [Silesian Univ. of Technology, Katowice (Poland). Dept. of Materials Science; Szeliga, Dariusz [Rzeszow Univ. of Technology (Poland). Dept. of Materials Science; Jarczyk, Jerzy [ALD Vacuum Technologies, Hanau (Germany)

    2013-08-01

    Modern single crystal (SX) turbine blades are fabricated by directional solidification using a grain selector. The grain selection process was investigated by numerical simulation and verified by the experiment. A coupled ProCAST and cellular automaton finite element (CAFE) model was used in this study. According to the latest literature data, we designed the grain selector. Simulation confirmed an optimal grain selection efficiency of the applied selector geometry. The obtained experimental results reveal the possibility of stray grain formation in SX castings with a designed selector, in contrast to the simulation results. (orig.)

  5. Indwelling Stent Embedded with Light-Emitting Diodes for Photodynamic Therapy of Malignant Biliary Obstruction

    International Nuclear Information System (INIS)

    Baran, Timothy M.; Mironov, Oleg; Sharma, Ashwani K.; Foster, Thomas H.

    2016-01-01

    PurposeWe describe the design and preliminary characterization of a stent incorporating light-emitting diodes (LEDs) for photodynamic therapy (PDT) of malignant biliary obstruction.MethodsA prototype was constructed with red (640 nm) LEDs embedded in a 14.5 French polyurethane tube. The device was evaluated for optical power and subjected to physical and electrical tests. PDT-induced reactive oxygen species were imaged in a gel phantom.ResultsThe stent functioned at a 2.5-cm bend radius and illuminated for 6 months in saline. No stray currents were detected, and it was cool after 30 minutes of operation. Optical power of 5–15 mW is applicable to PDT. Imaging of a reactive oxygen indicator showed LED-stent activation of photosensitizer.ConclusionsThe results motivate biological testing and design optimization.

  6. Indwelling Stent Embedded with Light-Emitting Diodes for Photodynamic Therapy of Malignant Biliary Obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Baran, Timothy M., E-mail: timothy.baran@rochester.edu [University of Rochester Medical Center, Department of Imaging Sciences (United States); Mironov, Oleg, E-mail: oleg.mironov@uhn.ca [University Health Network, The Joint Department of Medical Imaging (Canada); Sharma, Ashwani K., E-mail: Ashwani-Sharma@URMC.Rochester.edu; Foster, Thomas H., E-mail: thomas.foster@rochester.edu [University of Rochester Medical Center, Department of Imaging Sciences (United States)

    2016-06-15

    PurposeWe describe the design and preliminary characterization of a stent incorporating light-emitting diodes (LEDs) for photodynamic therapy (PDT) of malignant biliary obstruction.MethodsA prototype was constructed with red (640 nm) LEDs embedded in a 14.5 French polyurethane tube. The device was evaluated for optical power and subjected to physical and electrical tests. PDT-induced reactive oxygen species were imaged in a gel phantom.ResultsThe stent functioned at a 2.5-cm bend radius and illuminated for 6 months in saline. No stray currents were detected, and it was cool after 30 minutes of operation. Optical power of 5–15 mW is applicable to PDT. Imaging of a reactive oxygen indicator showed LED-stent activation of photosensitizer.ConclusionsThe results motivate biological testing and design optimization.

  7. Fauna of Zoontic Parasites of Stray Dogs in Yasouj Suburbs in 2008

    Directory of Open Access Journals (Sweden)

    A Moshfe

    2011-04-01

    Full Text Available Introduction & Objective: Dogs are among the closest animals to human residents and can by useful for human. A few of zoontic diseases are prevalent in Iran. Dogs are the reservoirs of many of these zoonosis and a major role in transmission of infection. The aim of this study was to determine the zoonotic parasitic fauna of stray dogs in Yasuj Materials & Methods: In this descriptive study which was conducted at Yasuj suburbs in 2008, 25 dogs’ corpses were necropsied and their tissues were studied for parasitic infections. Collected parasites were placed in special containers and stained for genus and species diagnosis based on their morphological features. The collected data were analyzed with the SPSS software, using descriptive analysis. Results: Of the 25 studied corpses, 23 dogs were infected with at least one parasite. Helminthic infections of dogs were consisted of: Taenia hydatigena, Mesocestoides sp., Echinococcus granulosus, Dipylidium caninum, Macracanthorhynchus hirudinaceus and Spirocerca lupi. Conclusion: Four of six detected helminthes in in dogs in this study are zoonotic parasites which are important in human diseases. Among them larval stage of Echinococcus granulosus which causes hydatid cyst disease in human is very important. Control programs should be implemented in this region to prevent these zoonotic diseases.

  8. Instrumentation maintenance

    International Nuclear Information System (INIS)

    Mack, D.A.

    1976-09-01

    It is essential to any research activity that accurate and efficient measurements be made for the experimental parameters under consideration for each individual experiment or test. Satisfactory measurements in turn depend upon having the necessary instruments and the capability of ensuring that they are performing within their intended specifications. This latter requirement can only be achieved by providing an adequate maintenance facility, staffed with personnel competent to understand the problems associated with instrument adjustment and repair. The Instrument Repair Shop at the Lawrence Berkeley Laboratory is designed to achieve this end. The organization, staffing and operation of this system is discussed. Maintenance policy should be based on studies of (1) preventive vs. catastrophic maintenance, (2) records indicating when equipment should be replaced rather than repaired and (3) priorities established to indicate the order in which equipment should be repaired. Upon establishing a workable maintenance policy, the staff should be instructed so that they may provide appropriate scheduled preventive maintenance, calibration and corrective procedures, and emergency repairs. The education, training and experience of the maintenance staff is discussed along with the organization for an efficient operation. The layout of the various repair shops is described in the light of laboratory space and financial constraints

  9. Designing Light Beam Transmittance Measuring Tool Using a Laser Pointer

    Science.gov (United States)

    Nuroso, H.; Kurniawan, W.; Marwoto, P.

    2016-08-01

    A simple instrument used for measuring light beam transmittance percentage made of window film has been developed. The instrument uses a laser pointer of 405 nm and 650 nm ±10% as a light source. Its accuracy approaches 80%. Transmittance data was found by comparing the light beam before and after passing the window film. The light intensity measuring unit was deleted by splitting the light source into two beams through a beam splitter. The light beam was changed into resistance by a NORP12 LDR sensor designed at a circuit of voltage divider rule of Khirchoff's laws. This conversion system will produce light beam intensity received by the sensor to become an equal voltage. This voltage will, then, be presented on the computer screen in the form of a real time graph via a 2.0 USB data transfer.

  10. Detecting stray microwaves and nonequilibrium quasiparticles in thin films by single-electron tunneling

    Science.gov (United States)

    Saira, Olli-Pentti; Maisi, Ville; Kemppinen, Antti; Möttönen, Mikko; Pekola, Jukka

    2013-03-01

    Superconducting thin films and tunnel junctions are the building blocks of many state-of-the-art technologies related to quantum information processing, microwave detection, and electronic amplification. These devices operate at millikelvin temperatures, and - in a naive picture - their fidelity metrics are expected to improve as the temperature is lowered. However, very often one finds in the experiment that the device performance levels off around 100-150 mK. In my presentation, I will address three common physical mechanisms that can cause such saturation: stray microwaves, nonequilibrium quasiparticles, and sub-gap quasiparticle states. The new experimental data I will present is based on a series of studies on quasiparticle transport in Coulomb-blockaded normal-insulator-superconductor tunnel junction devices. We have used a capacitively coupled SET electrometer to detect individual quasiparticle tunneling events in real time. We demonstrate the following record-low values for thin film aluminum: quasiparticle density nqp < 0 . 033 / μm3 , normalized density of sub-gap quasiparticle states (Dynes parameter) γ < 1 . 6 ×10-7 . I will also discuss some sample stage and chip designs that improve microwave shielding.

  11. Low-T, Low-Q Cryocoolers for Science Instruments

    Data.gov (United States)

    National Aeronautics and Space Administration — The purpose of the planned research is to advance the current space science instruments through the development of light weight and low power cryocoolers. Currently,...

  12. Reactor instrumentation experience at IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Soares, A.J.

    1997-01-01

    The Instituto de Pesquisas Energeticas e Nucleares (IPEN) in Sao Paulo started in 1977 development of nuclear instrumentation. In 1982 two groups were established, one responsible for maintenance of electronic equipment and the other, the Nuclear Instrumentation Section (NIS), for new projects, such as a light water moderated critical facility (IPEN/MB-0). The NIS had the responsibility to execute all necessary activities to develop the ''nonconventional'' instrumentation systems: control, protection and radiation monitoring for the IPEN/MB-01 facility. After the commissioning of the critical facility the NIS group started the development of instrumentation systems for a power reactor. As a first step an overall review of the quality assurance programme was implemented. In parallel the development of self powered detectors was carried out. (author). 7 figs

  13. Photoacoustic Soot Spectrometer (PASS) Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Dubey, M [Los Alamos National Laboratory; Springston, S [Brookhaven National Laboratory; Koontz, A [Pacific Northwest National Laboratory; Aiken, A [Los Alamos National Laboratory

    2013-01-17

    The photoacoustic soot spectrometer (PASS) measures light absorption by aerosol particles. As the particles pass through a laser beam, the absorbed energy heats the particles and in turn the surrounding air, which sets off a pressure wave that can be detected by a microphone. The PASS instruments deployed by ARM can also simultaneously measure the scattered laser light at three wavelengths and therefore provide a direct measure of the single-scattering albedo. The Operator Manual for the PASS-3100 is included here with the permission of Droplet Measurement Technologies, the instrument’s manufacturer.

  14. Electron beam spectrum monitor using synchrotron light

    International Nuclear Information System (INIS)

    Reagan, D.; Hostetler, T.E.

    1979-03-01

    This instrument shows the positions, widths, and shapes of momentum spectra of SLAC beams. It uses synchrotron light produced when the beam is deflected by a magnet. Some of the light is focused on the face of an image splitter consisting of acrylic light pipes. The light pipes illuminate twelve photomultiplier tubes. Pulses from the PM tubes are integrated, multiplexed, and displayed on an oscilloscope. The resolution of the instrument is usually better than 0.2%. It has some advantages over the secondary emitter foil spectrum monitors (SEM's) currently in use at SLAC. It need never be put out of service to avoid disturbing the beam. It is as sensitive as the most sensitive SLAC SEM. (Its performance has been optimized for high-current beams; it can easily be made much more sensitive.) It provides information on a pulse-to-pulse basis and, with better cables, could indicate electron beam pulse shapes

  15. RASOR: an advanced instrument for soft x-ray reflectivity and diffraction.

    Science.gov (United States)

    Beale, T A W; Hase, T P A; Iida, T; Endo, K; Steadman, P; Marshall, A R; Dhesi, S S; van der Laan, G; Hatton, P D

    2010-07-01

    We report the design and construction of a novel soft x-ray diffractometer installed at Diamond Light Source. The beamline endstation RASOR is constructed for general users and designed primarily for the study of single crystal diffraction and thin film reflectivity. The instrument is comprised of a limited three circle (theta, 2theta, and chi) diffractometer with an additional removable rotation (phi) stage. It is equipped with a liquid helium cryostat, and post-scatter polarization analysis. Motorized motions are provided for the precise positioning of the sample onto the diffractometer center of rotation, and for positioning the center of rotation onto the x-ray beam. The functions of the instrument have been tested at Diamond Light Source, and initial test measurements are provided, demonstrating the potential of the instrument.

  16. Irradiation technology (1). Development of new in-pile instrumentation at JMTR

    International Nuclear Information System (INIS)

    Shibata, Akira; Kimura, Nobuaki; Tanimoto, Masataka; Nakamura, Jinichi; Saito, Takashi; Tsuchiya, Kunihiko

    2012-01-01

    Development of instrumentation which can use under severe accident condition is important issue for the purpose to cope with severe accident at nuclear reactors. And also to improve the quality of irradiation tests data and to increase the reliability of safety management system of reactors, the development of new instrumentation is key issue. JAEA is developing several in-pile instrumentations to conduct irradiation tests at JMTR. This study includes the developments of three new instrumentations and describes the characteristics of the instrumentations. These are ECP sensor, new water level indicator and in-reactor observation system using Cherenkov light. (author)

  17. Design Through Integration of On-Board Calibration Device with Imaging Spectroscopy Instruments

    Science.gov (United States)

    Stange, Michael

    2012-01-01

    The main purpose of the Airborne Visible and Infrared Imaging Spectroscopy (AVIRIS) project is to "identify, measure, and monitor constituents of the Earth's surface and atmosphere based on molecular absorption and particle scattering signatures." The project designs, builds, and tests various imaging spectroscopy instruments that use On-Board Calibration devices (OBC) to check the accuracy of the data collected by the spectrometers. The imaging instrument records the spectral signatures of light collected during flight. To verify the data is correct, the OBC shines light which is collected by the imaging spectrometer and compared against previous calibration data to track spectral response changes in the instrument. The spectral data has the calibration applied to it based on the readings from the OBC data in order to ensure accuracy.

  18. New instruments for radiation protection

    International Nuclear Information System (INIS)

    Bartos, D.; Ciobanu, M.; Constantin, F.; Petcu, M.; Plostinaru, V.D.; Rusu, Al.; Lupu, A.C.; Lupu, F.

    2003-01-01

    Though a century old, the radiation protection is actual by its purpose: a dose as low as reasonable achievable is to be received either by involved professionals or population. This threshold is dependent on the technical progress. Some major developments like surface mounted device technology, consumer almost ideal operational amplifiers, microcontrollers and the news signal digital processing techniques, offer the opportunity to design improved instruments for radioprotection. To put in a light portable instrument both the whole measuring system and the 'intelligence' - a microcontroller and the associated software - are the main ideas applied by the authors. The result is presented: a family of eight members, at least, based on two parents. (authors)

  19. Feasibility of Optical Instruments Based on Multiaperture Optics.

    Science.gov (United States)

    1984-10-16

    system may be configured. The optical elements may be nonimaging concentrators (light horns), the field of view (FOV) of which may be controlled by a...RD-RI58 868 FEASIBILITY OF OPTICAL INSTRUMENTS BASED ON i/I MULTIAPERTURE OPTICS (U) FLORIDA UNIV GAINESVILLE DEPT OF NUCLEAR ENGINEERING SCIENCES J D...d Subtitle) 5. TYPE OF REPORT & PERIOD COVERED ’ 0 Feasibility of Optical Instruments Based on Final Report * CD Multiaperature Optics 615/83 to 9/30

  20. Development and application of a novel crop stress and quality instrument

    Science.gov (United States)

    Huang, Wengjiang; Sun, Gang; Wang, Jihua; Liu, Liangyun; Zheng, Wengang

    2005-12-01

    In this paper, a portable diagnostic instrument for crop quality analysis was designed and tested, which can measure the normalized difference vegetation index (PRI) and structure insensitive pigment index (NRI) of crop canopy in the field. The instrument have a valid survey area of 1m×1m when the height between instrument and the ground was fixed to 1.3 meter. The crop quality can be assessed based on their PRI and NRI values, so it will be very important for crop management to get these values. The instrument uses sunlight as its light source. There are six special different photoelectrical detectors within red, blue and near infrared bands, which are used for detecting incidence sunlight and reflex light from the canopy of crop. This optical instrument includes photoelectric detector module, signal process and A/D convert module, the data storing and transmission module and human-machine interface module. The detector is the core of the instrument which measures the spectrums at special bands. The microprocessor calculates the NDVI and SIPI value based on the A/D value. And the value can be displayed on the instrument's LCD, stored in the flash memory of instrument and can also be uploaded to PC through the PC's RS232 serial interface. The prototype was tested in the crop field at different view directions. It reveals the on-site and non-sampling mode of crop growth monitoring by fixed on the agricultural machine traveling in the field. Such simple instruments can diagnose the plant growth status by the acquired spectral response.

  1. Using XML and Java for Astronomical Instrumentation Control

    Science.gov (United States)

    Ames, Troy; Koons, Lisa; Sall, Ken; Warsaw, Craig

    2000-01-01

    Traditionally, instrument command and control systems have been highly specialized, consisting mostly of custom code that is difficult to develop, maintain, and extend. Such solutions are initially very costly and are inflexible to subsequent engineering change requests, increasing software maintenance costs. Instrument description is too tightly coupled with details of implementation. NASA Goddard Space Flight Center is developing a general and highly extensible framework that applies to any kind of instrument that can be controlled by a computer. The software architecture combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML), a human readable and machine understandable way to describe structured data. A key aspect of the object-oriented architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). ]ML is used to describe graphical user interfaces to control and monitor the instrument, command sets and command formats, data streams, and communication mechanisms. Although the current effort is targeted for the High-resolution Airborne Wideband Camera, a first-light instrument of the Stratospheric Observatory for Infrared Astronomy, the framework is designed to be generic and extensible so that it can be applied to any instrument.

  2. Design and validation of portable optical instrument for crop diagnose

    Science.gov (United States)

    Sun, Gang; Zheng, Wengang; Huang, Wengjiang; Wan, Huawei; Liu, Liangyun

    2005-12-01

    In this paper, a portable diagnostic instrument was designed and tested, which can measure the normalized difference vegetation index (NDVI) and structure insensitive pigment index (SIPI) of crop canopy in field. The instrument have a valid survey area of 1 m*1 m when the height between instrument and the ground was fixed to 1.3 meter The crop growth condition can be assessed based on their NDVI and SIPI values, so it will be very important for crop management to get these values. The instrument uses sunlight as its light source. There are six special different photoelectrical detectors within red, blue and near infrared bands, which are used for detecting incidence sunlight and reflex light from the canopy of crop. This optical instrument includes photoelectric detector module, signal process and A/D convert module, the data storing and transmission module and human-machine interface module. The detector is the core of the instrument which measures the spectrums at special bands. The microprocessor calculates the NDVI and SIPI value based on the A/D value. And the value can be displayed on the instrument's LCD, stored in the flash memory of instrument and can also be uploaded to PC through the PC's RS232 serial interface. The prototype was tested in the crop field at different view directions. This paper also provided the method of calibration, the results showed that the average measurement error to SIPI value of instrument was 5.25% and the average measurement error to NDVI value in vegetation-covered region is 6.40%. It reveals the on-site and non-sampling mode of crop growth monitoring by fixed on the agricultural machine traveling in the field.

  3. A measurement instrument for bone mineral content of adult and children

    International Nuclear Information System (INIS)

    Liu Shaofang

    1996-01-01

    The γ radiation source was used in bone mineral content measurement analysis of adult and children and a new instrument is developed successfully. It's precision is +2%. The advantage of this instrument is light, cheap and reliable. It can be used widely in medical science and clinic for diagnosis on certain diseases and research work

  4. Standardization of portable assay instrumentation: the neutron-coincidence tree

    International Nuclear Information System (INIS)

    Menlove, H.O.

    1983-01-01

    Standardization of portable neutron assay instrumentation has been achieved by using the neutron coincidence technique as a common basis for a wide range of instruments and applications. The electronics originally developed for the High-Level Neutron Coincidence Counter has been adapted to both passive- and active-assay instrumentation for field verification of bulk plutonium, inventory samples, pellets, powders, nitrates, high-enriched uranium, and materials-testing-reactor, light-water-reactor, and mixed-oxide fuel assemblies. The family of detectors developed at Los Alamos National Laboratory and their performance under in-field conditions are described. 16 figures, 3 tables

  5. Prevalence and characterization of Escherichia coli and Salmonella strains isolated from stray dog and coyote feces in a major leafy greens production region at the United States-Mexico border.

    Directory of Open Access Journals (Sweden)

    Michele T Jay-Russell

    Full Text Available In 2010, Romaine lettuce grown in southern Arizona was implicated in a multi-state outbreak of Escherichia coli O145:H28 infections. This was the first known Shiga toxin-producing E. coli (STEC outbreak traced to the southwest desert leafy green vegetable production region along the United States-Mexico border. Limited information exists on sources of STEC and other enteric zoonotic pathogens in domestic and wild animals in this region. According to local vegetable growers, unleashed or stray domestic dogs and free-roaming coyotes are a significant problem due to intrusions into their crop fields. During the 2010-2011 leafy greens growing season, we conducted a prevalence survey of STEC and Salmonella presence in stray dog and coyote feces. Fresh fecal samples from impounded dogs and coyotes from lands near produce fields were collected and cultured using extended enrichment and serogroup-specific immunomagnetic separation (IMS followed by serotyping, pulsed-field gel electrophoresis (PFGE, and antimicrobial susceptibility testing. A total of 461 fecal samples were analyzed including 358 domestic dog and 103 coyote fecals. STEC was not detected, but atypical enteropathogenic E. coli (aEPEC strains comprising 14 different serotypes were isolated from 13 (3.6% dog and 5 (4.9% coyote samples. Salmonella was cultured from 33 (9.2% dog and 33 (32% coyote samples comprising 29 serovars with 58% from dogs belonging to Senftenberg or Typhimurium. PFGE analysis revealed 17 aEPEC and 27 Salmonella distinct pulsotypes. Four (22.2% of 18 aEPEC and 4 (6.1% of 66 Salmonella isolates were resistant to two or more antibiotic classes. Our findings suggest that stray dogs and coyotes in the desert southwest may not be significant sources of STEC, but are potential reservoirs of other pathogenic E. coli and Salmonella. These results underscore the importance of good agriculture practices relating to mitigation of microbial risks from animal fecal deposits in the

  6. Design considerations for highly effective fluorescence excitation and detection optical systems for molecular diagnostics

    Science.gov (United States)

    Kasper, Axel; Van Hille, Herbert; Kuk, Sola

    2018-02-01

    Modern instruments for molecular diagnostics are continuously optimized for diagnostic accuracy, versatility and throughput. The latest progress in LED technology together with tailored optics solutions allows developing highly efficient photonics engines perfectly adapted to the sample under test. Super-bright chip-on-board LED light sources are a key component for such instruments providing maximum luminous intensities in a multitude of narrow spectral bands. In particular the combination of white LEDs with other narrow band LEDs allows achieving optimum efficiency outperforming traditional Xenon light sources in terms of energy consumption, heat dissipation in the system, and switching time between spectral channels. Maximum sensitivity of the diagnostic system can only be achieved with an optimized optics system for the illumination and imaging of the sample. The illumination beam path must be designed for optimum homogeneity across the field while precisely limiting the angular distribution of the excitation light. This is a necessity for avoiding spill-over to the detection beam path and guaranteeing the efficiency of the spectral filtering. The imaging optics must combine high spatial resolution, high light collection efficiency and optimized suppression of excitation light for good signal-to-noise ratio. In order to achieve minimum cross-talk between individual wells in the sample, the optics design must also consider the generation of stray light and the formation of ghost images. We discuss what parameters and limitations have to be considered in an integrated system design approach covering the full path from the light source to the detector.

  7. 76 FR 48803 - Application(s) for Duty-Free Entry of Scientific Instruments

    Science.gov (United States)

    2011-08-09

    .... Manufacturer: FEI Company, The Netherlands. Intended Use: The instrument will be used for NIH-funded basic... Applied Life Sciences, Austria. Intended Use: The instrument is a highly specialized system for studying a wide range of materials used in very high cycle, high temperature applications, such as light metals...

  8. Current and future health physics research at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Hickman, D.P.

    1993-01-01

    Lawrence Livermore National Laboratory has developed several radiation protection instruments and continues to pursue new approaches in this area. Some of the instruments developed include innovative air-monitoring systems; neutron detection and dosimetry systems; specialized calibration materials and structures, such as the LLNL Realistic Torso Phantom; a fast-response detector system to detect stray beams from x-ray fluorescence devices that can be manufactured for less than $600; and a reliable, light weight personnel air-monitoring system that can be incorporated into a security badge/dosimeter package. A multi-disciplinary team of experts at LLNL is developing and testing cleanable/reusable high-efficiency particulate air-filtration systems and highly sensitive instrumentation for differentiating transuranic waste from nontransuranic waste; developing an advanced detector and circuit design for a hand-held neutron spectrometer; developing techniques for detecting neutron sources using CR-39 and for calibrating in-vivo measurement equipment using Magnetic Resonance Imaging and Monte Carlo simulation; and developing a seamless bottle mannequin adsorption (BOMAB) phantom with recessed fill caps, which have no potential for leakage of liquid sources used for calibrating whole-body counters

  9. Design, manufacturing and alignment of a fluorescence imaging spectrometer based on refractive optics and a transmission grating

    Science.gov (United States)

    Lousberg, G. P.; Lemagne, F.; Gloesener, P.; Flebus, C.; Rougelot, S.; Coatantiec, C.; Harnisch, B.

    2017-11-01

    In the framework of the Fluorescence Explorer (FLEX) phase A/B1 study, an elegant breadboard (EBB) of an imaging spectrometer is designed, manufactured and aligned by AMOS, with Airbus Defence&Space as the prime Contractor of the study. The FLEX mission is one of the two candidates of the 8th Earth Explorer mission. The main constituting instrument of the FLEX mission is an imaging spectrometer observing vegetation fluorescence and reflectance with a high- and a low-resolution channels in the 500 nm -780 nm band. As part of the system feasibility study of the mission, a breadboard of the high-resolution channel of the instrument is designed and manufactured with a high representativeness of a future flight concept. The high-resolution channel is referred to as FIMAS (Fluorescence IMAging Spectrometer). The main purpose of the EBB is to demonstrate (1) the manufacturability of the instrument and (2) the compliance of the optical performances with respect to the science requirements (including spatial and spectral resolution and stray-light).

  10. Development of a new reference spectrophotometer

    International Nuclear Information System (INIS)

    Zwinkels, J.C.; Gignac, D.S.

    1989-01-01

    A new reference spectrophotometer is being developed at the National Research Council of Canada (NRCC) for high-accuracy transmittance measurements over the spectral range 200 to 250 nm. This computerized instrument is a single-beam design based upon a servomotor-driven double monochromator with a wavelength resolution of 0.022 nm. The other main components are: two interchangeable sources (deuterium and tungsten-halogen), two computer-selectable TE-cooled detectors (GaAs photomultiplier tube and PbS cell), all-reflective input and exit optics, and a large sample compartment. The significant feature of the optical system is a large, well-collimated measurement beam: the angle of convergence is 0.7 degrees for a slit height of 7 mm, and the maximal beam size is 37 x 20 mm. This beam geometry eliminates the need for polarization corrections (using linearly polarized light) or compensation for spatially non-uniform detector responsivity (using averaging sphere). The paper describes the instrument design and presents data from preliminary performance tests. The systematic and random sources of error that have been investigated include: wavelength accuracy and reproducibility, bandpass, beam uniformity, polarization, stray light, system drift and linearity

  11. Measurement of stray radiation within a scanning proton therapy facility: EURADOS WG9 intercomparison exercise of active dosimetry systems

    Energy Technology Data Exchange (ETDEWEB)

    Farah, J., E-mail: jad.farah@irsn.fr; Trompier, F. [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Pôle Radioprotection de l’Homme, BP17, Fontenay-aux-Roses 92260 (France); Mares, V.; Schinner, K.; Wielunski, M. [Helmholtz Zentrum München, Institute of Radiation Protection, Ingolstädter Landstraße 1, Neuherberg 85764 (Germany); Romero-Expósito, M.; Domingo, C. [Departament de Física, Universitat Autònoma de Barcelona, Bellaterra E-08193 (Spain); Trinkl, S. [Helmholtz Zentrum München, Institute of Radiation Protection, Ingolstädter Landstraße 1, Neuherberg 85764, Germany and Physik-Department, Technische Universität München, Garching 85748 (Germany); Dufek, V. [Czech Technical University in Prague, FNSPE, Břehová 7, Prague 115 19, Czech Republic and National Radiation Protection Institute, Bartoškova 28, Prague 140 00 (Czech Republic); Klodowska, M.; Liszka, M.; Stolarczyk, L.; Olko, P. [Institute of Nuclear Physics PAN, Radzikowskiego 152, Krakow 31-342 (Poland); Kubancak, J. [Czech Technical University in Prague, FNSPE, Břehová 7, Prague 115 19, Czech Republic and Department of Radiation Dosimetry, Nuclear Physics Institute, Řež CZ-250 68 (Czech Republic); and others

    2015-05-15

    Purpose: To characterize stray radiation around the target volume in scanning proton therapy and study the performance of active neutron monitors. Methods: Working Group 9 of the European Radiation Dosimetry Group (EURADOS WG9—Radiation protection in medicine) carried out a large measurement campaign at the Trento Centro di Protonterapia (Trento, Italy) in order to determine the neutron spectra near the patient using two extended-range Bonner sphere spectrometry (BSS) systems. In addition, the work focused on acknowledging the performance of different commercial active dosimetry systems when measuring neutron ambient dose equivalents, H{sup ∗}(10), at several positions inside (8 positions) and outside (3 positions) the treatment room. Detectors included three TEPCs—tissue equivalent proportional counters (Hawk type from Far West Technology, Inc.) and six rem-counters (WENDI-II, LB 6411, RadEye™ NL, a regular and an extended-range NM2B). Meanwhile, the photon component of stray radiation was deduced from the low-lineal energy transfer part of TEPC spectra or measured using a Thermo Scientific™ FH-40G survey meter. Experiments involved a water tank phantom (60 × 30 × 30 cm{sup 3}) representing the patient that was uniformly irradiated using a 3 mm spot diameter proton pencil beam with 10 cm modulation width, 19.95 cm distal beam range, and 10 × 10 cm{sup 2} field size. Results: Neutron spectrometry around the target volume showed two main components at the thermal and fast energy ranges. The study also revealed the large dependence of the energy distribution of neutrons, and consequently of out-of-field doses, on the primary beam direction (directional emission of intranuclear cascade neutrons) and energy (spectral composition of secondary neutrons). In addition, neutron mapping within the facility was conducted and showed the highest H{sup ∗}(10) value of ∼51 μSv Gy{sup −1}; this was measured at 1.15 m along the beam axis. H{sup ∗}(10) values

  12. Radiation protection instrumentation for personnel dosimetry, area and environmental monitoring

    International Nuclear Information System (INIS)

    Jones, A.R.

    1978-04-01

    Several kinds of personal dosimeter exist and their performance is reviewed in the light of requirements for an ideal instrument. The requirements of portable instruments are reviewed and the extent to which they are met in one example is described. Where permitted environmental doses are larger than the fluctuations in natural backgrounds, certain types of thermoluminescent dosimeters provide a cheaper and reliable alternative measuring system

  13. Quantitative assessment of apical debris extrusion and intracanal debris in the apical third, using hand instrumentation and three rotary instrumentation systems.

    Science.gov (United States)

    H K, Sowmya; T S, Subhash; Goel, Beena Rani; T N, Nandini; Bhandi, Shilpa H

    2014-02-01

    Decreased apical extrusion of debris and apical one third debris have strong implications for decreased incidence of postoperative inflammation and pain. Thus, the aim of this study was to assess quantitatively the apical extrusion of debris and intracanal debris in the apical third during root canal instrumentation using hand and three different types of rotary instruments. Sixty freshly extracted single rooted human teeth were randomly divided into four groups. Canal preparation was done using step-back with hand instrumentation, crown-down technique with respect to ProTaper and K3, and hybrid technique with LightSpeed LSX. Irrigation was done with NaOCl, EDTA, and normal saline and for final irrigation, EndoVac system was used. The apically extruded debris was collected on the pre-weighed Millipore plastic filter disk and weighed using microbalance. The teeth were submitted to the histological processing. Sections from the apical third were analyzed by a trinocular research microscope that was coupled to a computer where the images were captured and analyzed using image proplus V4.1.0.0 software. The mean weight of extruded debris for each group and intracanal debris in the root canal was statistically analyzed by a Kruskal-Wallis one-way analysis of variance and Mann-Whitney U test. The result showed that, hand instrumentation using K files showed the highest amount of debris extrusion apically when compared to ProTaper, K3 and LightSpeed LSX. The result also showed that there was no statistically significant difference between the groups in relation to presence of intracanal debris in the apical one third. Based on the results, all instrumentation techniques produced debris extrusion. The engine driven Ni-Ti systems extruded significantly less apical debris than hand instrumentation. There was no statistically significant difference between the groups in relation to presence of intracanal debris in the apical one third.

  14. Prevalence of selected infectious disease agents in stray cats in Catalonia, Spain

    Directory of Open Access Journals (Sweden)

    Sara Ravicini

    2016-02-01

    Full Text Available Objectives The objective of the current study was to investigate the prevalence rates of the following infectious agents in 116 stray cats in the Barcelona area of Spain: Anaplasma phagocytophilum, Bartonella species, Borrelia burgdorferi, Chlamydia felis, Dirofilaria immitis, Ehrlichia species, feline calicivirus (FCV, feline herpesvirus-1 (FHV-1, feline leukaemia virus (FeLV, feline immunodeficiency virus (FIV, haemoplasmas, Mycoplasma species and Rickettsia species. Methods Serum antibodies were used to estimate the prevalence of exposure to A phagocytophilum, Bartonella species, B burgdorferi, Ehrlichia species and FIV; serum antigens were used to assess for infection by D immitis and FeLV; and molecular assays were used to amplify nucleic acids of Anaplasma species, Bartonella species, C felis, D immitis, Ehrlichia species, FCV, FHV-1, haemoplasmas, Mycoplasma species and Rickettsia species from blood and nasal or oral swabs. Results Of the 116 cats, 63 (54.3% had evidence of infection by Bartonella species, FeLV, FIV or a haemoplasma. Anaplasma species, Ehrlichia species or Rickettsia species DNA was not amplified from these cats. A total of 18/116 cats (15.5% were positive for FCV RNA (six cats, Mycoplasma species DNA (six cats, FHV-1 DNA (three cats or C felis DNA (three cats. Conclusions and relevance This study documents that shelter cats in Catalonia are exposed to many infectious agents with clinical and zoonotic significance, and that flea control is indicated for cats in the region.

  15. Visualization of gas dissolution following upward gas migration in porous media: Technique and implications for stray gas

    Science.gov (United States)

    Van De Ven, C. J. C.; Mumford, Kevin G.

    2018-05-01

    The study of gas-water mass transfer in porous media is important in many applications, including unconventional resource extraction, carbon storage, deep geological waste storage, and remediation of contaminated groundwater, all of which rely on an understanding of the fate and transport of free and dissolved gas. The novel visual technique developed in this study provided both quantitative and qualitative observations of gas-water mass transfer. Findings included interaction between free gas architecture and dissolved plume migration, plume geometry and longevity. The technique was applied to the injection of CO2 in source patterns expected for stray gas originating from oil and gas operations to measure dissolved phase concentrations of CO2 at high spatial and temporal resolutions. The data set is the first of its kind to provide high resolution quantification of gas-water dissolution, and will facilitate an improved understanding of the fundamental processes of gas movement and fate in these complex systems.

  16. An Intelligent Lighting Control System (ILCS) using LabVIEW ...

    African Journals Online (AJOL)

    An Intelligent Lighting Control System (ILCS) was proposed and designed by considering ergonomic setting and energy efficiency. The integration of CompactRIO as a main hardware and National Instrument Laboratory Virtual Instrument Engineering Workbench (NI LabVIEW) 2012 as a platform to design an interactive ...

  17. Report from the Light Water Reactor Sustainability Workshop on Advanced Instrumentation, Information, and Control Systems and Human-System Interface Technologies

    International Nuclear Information System (INIS)

    Hallbert, Bruce P.; Persensky, J.J.; Smidts, Carol; Aldemir, Tunc; Naser, Joseph

    2009-01-01

    The Light Water Reactor Sustainability (LWRS) Program is a research and development (R and D) program sponsored by the U.S. Department of Energy (DOE). The program is operated in close collaboration with industry R and D programs to provide the technical foundations for licensing and managing the long-term, safe, and economical operation of Nuclear Power Plants that are currently in operation. The LWRS Program focus is on longer-term and higher-risk/reward research that contributes to the national policy objectives of energy and environmental security. Advanced instruments and control (I and C) technologies are needed to support the safe and reliable production of power from nuclear energy systems during sustained periods of operation up to and beyond their expected licensed lifetime. This requires that new capabilities to achieve process control be developed and eventually implemented in existing nuclear assets. It also requires that approaches be developed and proven to achieve sustainability of I and C systems throughout the period of extended operation. The strategic objective of the LWRS Program Advanced Instrumentation, Information, and Control Systems Technology R and D pathway is to establish a technical basis for new technologies needed to achieve safety and reliability of operating nuclear assets and to implement new technologies in nuclear energy systems. This will be achieved by carrying out a program of R and D to develop scientific knowledge in the areas of: (1) Sensors, diagnostics, and prognostics to support characterization and prediction of the effects of aging and degradation phenomena effects on critical systems, structures, and components (SSCs); (2) Online monitoring of SSCs and active components, generation of information, and methods to analyze and employ online monitoring information; (3) New methods for visualization, integration, and information use to enhance state awareness and leverage expertise to achieve safer, more readily available

  18. Report from the Light Water Reactor Sustainability Workshop on Advanced Instrumentation, Information, and Control Systems and Human-System Interface Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Bruce P. Hallbert; J. J. Persensky; Carol Smidts; Tunc Aldemir; Joseph Naser

    2009-08-01

    The Light Water Reactor Sustainability (LWRS) Program is a research and development (R&D) program sponsored by the U.S. Department of Energy (DOE). The program is operated in close collaboration with industry R&D programs to provide the technical foundations for licensing and managing the long-term, safe, and economical operation of Nuclear Power Plants that are currently in operation. The LWRS Program focus is on longer-term and higher-risk/reward research that contributes to the national policy objectives of energy and environmental security. Advanced instruments and control (I&C) technologies are needed to support the safe and reliable production of power from nuclear energy systems during sustained periods of operation up to and beyond their expected licensed lifetime. This requires that new capabilities to achieve process control be developed and eventually implemented in existing nuclear assets. It also requires that approaches be developed and proven to achieve sustainability of I&C systems throughout the period of extended operation. The strategic objective of the LWRS Program Advanced Instrumentation, Information, and Control Systems Technology R&D pathway is to establish a technical basis for new technologies needed to achieve safety and reliability of operating nuclear assets and to implement new technologies in nuclear energy systems. This will be achieved by carrying out a program of R&D to develop scientific knowledge in the areas of: • Sensors, diagnostics, and prognostics to support characterization and prediction of the effects of aging and degradation phenomena effects on critical systems, structures, and components (SSCs) • Online monitoring of SSCs and active components, generation of information, and methods to analyze and employ online monitoring information • New methods for visualization, integration, and information use to enhance state awareness and leverage expertise to achieve safer, more readily available electricity generation

  19. Optoelectronic Capillary Sensors in Microfluidic and Point-of-Care Instrumentation

    Directory of Open Access Journals (Sweden)

    Michał Borecki

    2010-04-01

    Full Text Available This paper presents a review, based on the published literature and on the authors’ own research, of the current state of the art of fiber-optic capillary sensors and related instrumentation as well as their applications, with special emphasis on point-of-care chemical and biochemical sensors, systematizing the various types of sensors from the point of view of the principles of their construction and operation. Unlike classical fiber-optic sensors which rely on changes in light propagation inside the fiber as affected by outside conditions, optical capillary sensors rely on changes of light transmission in capillaries filled with the analyzed liquid, which opens the possibility of interesting new applications, while raising specific issues relating to the construction, materials and instrumentation of those sensors.

  20. Characterization of diffraction gratings scattering in uv and ir for space applications

    Science.gov (United States)

    Achour, Sakina; Kuperman-Le Bihan, Quentin; Etcheto, Pierre

    2017-09-01

    The use of Bidirectional Scatter Distribution Function (BSDF) in space industry and especially when designing telescopes is a key feature. Indeed when speaking about space industry, one can immediately think about stray light issues. Those important phenomena are directly linked to light scattering. Standard BSDF measurement goniophotometers often have a resolution of about 0.1° and are mainly working in or close to the visible spectrum. This resolution is far too loose to characterize ultra-polished surfaces. Besides, wavelength range of BSDF measurements for space projects needs to be done far from visible range. How can we measure BSDF of ultra-polished surfaces and diffraction gratings in the UV and IR range with high resolution? We worked on developing a new goniophometer bench in order to be able to characterize scattering of ultra-polished surfaces and diffraction gratings used in everyday space applications. This ten meters long bench was developed using a collimated beam approach as opposed to goniophotometer using focused beam. Sources used for IR characterization were CO2 (10.6?m) and Helium Neon (3.39?m) lasers. Regarding UV sources, a collimated and spatially filtered UV LED was used. The detection was ensure by a photomultiplier coupled with synchronous detection as well as a MCT InSb detector. The so-built BSDF measurement instrument allowed us to measure BSDF of ultra-polished surfaces as well as diffraction gratings with an angular resolution of 0.02° and a dynamic of 1013 in the visible range. In IR as well as in UV we manage to get 109 with same angular resolution of 0.02°. The 1m arm and translation stages allows us to measure samples up to 200mm. Thanks to such a device allowing ultra-polished materials as well as diffraction gratings scattering characterization, it is possible to implement those BSDF measurements into simulation software and predict stray light issues. This is a big help for space industry engineers to apprehend stray light

  1. On-board target acquisition for CHEOPS

    Science.gov (United States)

    Loeschl, P.; Ferstl, R.; Kerschbaum, F.; Ottensamer, R.

    2016-07-01

    The CHaracterising ExOPlanet Satellite (CHEOPS) is the first ESA S-class and exoplanetary follow-up mission headed for launch in 2018. It will perform ultra-high-precision photometry of stars hosting confirmed exoplanets on a 3-axis stabilised sun-synchronous orbit that is optimised for uninterrupted observations at minimum stray light and thermal variations. Nevertheless, due to the satellites structural design, the alignment of the star trackers and the payload instrument telescope is affected by thermo-elastic deformations. This causes a high pointing uncertainty, which requires the payload instrument to provide an additional acquisition system for distinct target identification. Therefor a star extraction software and two star identification algorithms, originally designed for star trackers, were adapted and optimised for the special case of CHEOPS. In order to evaluate these algorithms reliability, thousands of random star configurations were analysed in Monte-Carlo simulations. We present the implemented identification methods and their performance as well as recommended parameters that guarantee a successful identification under all conditions.

  2. Study of an integral field spectrograph for the SNAP satellite. Prototype, simulation and performances

    International Nuclear Information System (INIS)

    Aumeunier, Marie-Helene

    2007-01-01

    The SNAP (Supernovae/Acceleration Probe) project plans to measure very precisely the cosmological parameters and to determine the nature of dark energy by observations of type Ia supernovae and weak lensing. The SNAP instrument consists in a 2-meter telescope with a one square-degree imager and a spectrograph in the visible and infrared range. A dedicated optimized integral field spectrograph based on an imager slicer technology has been developed. To test and validate the performances, two approaches have been developed: a complete simulation of the complete instrument at the pixel level and the manufacturing and test of a spectrograph prototype operating at room temperature and in cryogenic environment. In this thesis we will test the optical and functional performances of the SNAP spectrograph: especially diffraction losses, stray-light and spectro-photometric calibration. We present an original approach for the spectro-photometric calibration adapted for the slicer and the optical performances resulting from the first measurement campaign in the visible range. (author) [fr

  3. Validation of Reverse-Engineered and Additive-Manufactured Microsurgical Instrument Prototype.

    Science.gov (United States)

    Singh, Ramandeep; Suri, Ashish; Anand, Sneh; Baby, Britty

    2016-12-01

    With advancements in imaging techniques, neurosurgical procedures are becoming highly precise and minimally invasive, thus demanding development of new ergonomically aesthetic instruments. Conventionally, neurosurgical instruments are manufactured using subtractive manufacturing methods. Such a process is complex, time-consuming, and impractical for prototype development and validation of new designs. Therefore, an alternative design process has been used utilizing blue light scanning, computer-aided designing, and additive manufacturing direct metal laser sintering (DMLS) for microsurgical instrument prototype development. Deviations of DMLS-fabricated instrument were studied by superimposing scan data of fabricated instrument with the computer-aided designing model. Content and concurrent validity of the fabricated prototypes was done by a group of 15 neurosurgeons by performing sciatic nerve anastomosis in small laboratory animals. Comparative scoring was obtained for the control and study instrument. T test was applied to the individual parameters and P values for force (P direct application of these additive-manufactured instruments in the operating room requires further validation. © The Author(s) 2016.

  4. Radiological instrument

    International Nuclear Information System (INIS)

    Kronenberg, S.; McLaughlin, W.L.; Seibentritt, C.R. Jr.

    1986-01-01

    An instrument is described for measuring radiation, particularly nuclear radiation, comprising: a radiation sensitive structure pivoted toward one end and including a pair of elongated solid members contiguously joined together along their length dimensions and having a common planar interface therebetween. One of the pairs of members is comprised of radiochromic material whose index of refraction changes due to anomolous dispersion as a result of being exposed to nuclear radiation. The pair of members further has mutually different indices of refraction with the member having the larger index of refraction further being transparent for the passage of light and of energy therethrough; means located toward the other end of the structure for varying the angle of longitudinal elevation of the pair of members; means for generating and projecting a beam of light into one end of the member having the larger index of refraction. The beam of light is projected toward the planar interface where it is reflected out of the other end of the same member as a first output beam; means projecting a portion of the beam of light into one end of the member having the larger index of refraction where it traverses therethrough without reflection and out of the other end of the same member as a second output beam; and means adjacent the structure for receiving the first and second output beams, whereby a calibrated change in the angle of elevation of the structure between positions of equal intensity of the first and second output beams prior to and following exposure provides a measure of the radiation sensed due to a change of refraction of the radiochromic material

  5. Integrated Instrumentation and Control Upgrade Plan

    International Nuclear Information System (INIS)

    Wilkinson, D.; Sun, B.; Wray, L.; Smith, J.

    1992-02-01

    This document presents the first industry-wide integrated research and development plan to support upgrading instrumentation and control (I ampersand C) systems in nuclear power plants in the United States. The plan encompasses both solving obsolescence problems and introducing modern I ampersand C technology into the industry. Accomplishing this plan will provide the technological base to modernize existing plants, as well as bridge the gap to meet Advanced Light Water Reactor (ALWR) requirements for modern I ampersand C systems. This plan defines Research and Development tasks to meet the identified needs for the following technical elements: Instrumentation, Control and Protection, Man-Machine Support Systems, Maintenance, Communications, Verification and Validation, and Specifications and Standards

  6. FAA Helicopter/Vertiport Lighting Conference - Proceedings

    National Research Council Canada - National Science Library

    Smith, Robert

    1999-01-01

    As the vertical flight industry moves into instrument flight rules (IFR) operations at heliports, it has become apparent to both FAA and the users that there is research and development to be done on heliport lighting...

  7. Studying the Mars atmosphere using a SOIR Instrument

    Science.gov (United States)

    Drummond, R.; Vandaele, A.; Daerden, F.; Neefs, E.; Mahieux, A.; Wilquet, V.; Montmessin, F.; Bertaux, J.; McConnell, J. C.; Kaminski, J. W.

    2009-05-01

    SOIR (Solar Occultation InfraRed spectrometer) is currently part of the SPICAV/SOIR instrument on board the Venus Express orbiter (VEX). SOIR, an Echelle infrared spectrometer using an acousto-optic tunable filter (AOTF) for the order selection, is probing the atmosphere by solar occultation, operating between 2.2 and 4.3 μm, with a resolution of 0.15 cm-1. This spectral range is suitable for the detection of several key components of planetary atmospheres, including H2O and its isotopologue HDO, CH4 and other trace species. The SOIR instrument was designed to have a minimum of moving parts, to be light and compact in order to fit on top of the SPICAV instrument. The AOTF allows a narrow range of wavelengths to pass, according to the radio frequency applied to the TeO2 crystal; this selects the order. The advantage of the AOTF is that different orders can be observed quickly and easily during one occultation. To obtain a compact optical scheme, a Littrow configuration was implemented in which the usual collimating and imaging lenses are merged into a single off-axis parabolic mirror. The light is diffracted on the echelle grating, where orders overlap and addition occurs, and finally is recorded by the detector. The detector is 320x256 pixels and is cooled to 88K during an occultation measurement, to maximise the signal to noise ratio. SOIR on VEX has been in orbit around Venus since April 2006, allowing us to characterise the instrument and study its performance. These data have allowed the engineering team to devise several instrumental improvements. The next step in further improving the readiness for Martian atmospheric studies comes in close collaboration with the Mars Atmospheric Modelling group at BIRA-IASB. A General Circulation Model is used to simulate the Martian atmosphere. Currently work is underway with SPICAM data to verify the GCM inputs and outputs. Later the GCM output will be used as feedback for instrumental design of both an improved version

  8. K-correlation power spectral density and surface scatter model

    Science.gov (United States)

    Dittman, Michael G.

    2006-08-01

    The K-Correlation or ABC model for surface power spectral density (PSD) and BRDF has been around for years. Eugene Church and John Stover, in particular, have published descriptions of its use in describing smooth surfaces. The model has, however, remained underused in the optical analysis community partially due to the lack of a clear summary tailored toward that application. This paper provides the K-Correlation PSD normalized to σ(λ) and BRDF normalized to TIS(σ,λ) in a format intended to be used by stray light analysts. It is hoped that this paper will promote use of the model by analysts and its incorporation as a standard tool into stray light modeling software.

  9. NASA Laser Light Scattering Advanced Technology Development Workshop, 1988

    Science.gov (United States)

    Meyer, William V. (Editor)

    1989-01-01

    The major objective of the workshop was to explore the capabilities of existing and prospective laser light scattering hardware and to assess user requirements and needs for a laser light scattering instrument in a reduced gravity environment. The workshop addressed experimental needs and stressed hardware development.

  10. 77 FR 61739 - Application(s) for Duty-Free Entry of Scientific Instruments

    Science.gov (United States)

    2012-10-11

    ... for which the instruments shown below are intended to be used, are being manufactured in the United... pump a dye laser to generate ultra-violet light which can be used to rack chemical species during... light (283 nm) will then fluoresce and can be detected using an intensified CCD camera. The key...

  11. Advanced Instrumentation, Information, and Control Systems Technologies Technical Program Plan

    Energy Technology Data Exchange (ETDEWEB)

    Bruce Hallbert

    2012-09-01

    Reliable instrumentation, information, and control (II&C) systems technologies are essential to ensuring safe and efficient operation of the U.S. light water reactor (LWR) fleet. These technologies affect every aspect of nuclear power plant (NPP) and balance-of-plant operations. In 1997, the National Research Council conducted a study concerning the challenges involved in modernization of digital instrumentation and control systems in NPPs. Their findings identified the need for new II&C technology integration.

  12. Improvements to the MST Thomson Scattering Diagnostic

    Science.gov (United States)

    Adams, D. T.; Borchardt, M. T.; den Hartog, D. J.; Holly, D. J.; Kile, T.; Kubala, S. Z.; Jacobson, C. M.; Thomas, M. A.; Wallace, J. P.; Young, W. C.; MST Thomson Scattering Team

    2017-10-01

    Multiple upgrades to the MST Thomson Scattering diagnostic have been implemented to expand capabilities of the system. In the past, stray laser light prevented electron density measurements everywhere and temperature measurements for -z/a >0.75. To mitigate stray light, a new laser beamline is being commissioned that includes a longer entrance flight tube, close-fitting apertures, and baffles. A polarizer has been added to the collection optics to further reduce stray light. An absolute density calibration using Rayleigh scattering in argon will be performed. An insertable integrating sphere will provide a full-system spectral calibration as well as maps optical fibers to machine coordinates. Reduced transmission of the collection optics due to coatings from plasma-surface interactions is regularly monitored to inform timely replacements of the first lens. Long-wavelength filters have been installed to better characterize non-Maxwellian electron distribution features. Previous work has identified residual photons not described by a Maxwellian distribution during m =0 magnetic bursts. Further effort to characterize the distribution function will be described. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Fusion Energy Sciences program under Award No. DE-FC02-05ER54814.

  13. Mobile device-based optical instruments for agriculture

    Science.gov (United States)

    Sumriddetchkajorn, Sarun

    2013-05-01

    Realizing that a current smart-mobile device such as a cell phone and a tablet can be considered as a pocket-size computer embedded with a built-in digital camera, this paper reviews and demonstrates on how a mobile device can be specifically functioned as a portable optical instrument for agricultural applications. The paper highlights several mobile device-based optical instruments designed for searching small pests, measuring illumination level, analyzing spectrum of light, identifying nitrogen status in the rice field, estimating chlorine in water, and determining ripeness level of the fruit. They are suitable for individual use as well as for small and medium enterprises.

  14. Improved instrumentation for intensity-, wavelength-, temperature-, and magnetic field-resolved photoconductivity spectroscopy

    International Nuclear Information System (INIS)

    Cottingham, Patrick; Morey, Jennifer R.; Lemire, Amanda; Lemire, Penny; McQueen, Tyrel M.

    2016-01-01

    We report instrumentation for photovoltage and photocurrent spectroscopy over a larger continuous range of wavelengths, temperatures, and applied magnetic fields than other instruments described in the literature: 350 nm≤λ≤1700 nm, 1.8 K≤T≤300 K, and B≤9 T. This instrument uses a modulated monochromated incoherent light source with total power<30 μW in combination with an LED in order to probe selected regions of non-linear responses while maintaining low temperatures and avoiding thermal artifacts. The instrument may also be used to measure a related property, the photomagnetoresistance. We demonstrate the importance of normalizing measured responses for variations in light power and describe a rigorous process for performing these normalizations. We discuss several circuits suited to measuring different types of samples and provide analysis for converting measured values into physically relevant properties. Uniform approaches to measurement of these photoproperties are essential for reliable quantitative comparisons between emerging new materials with energy applications. - Highlights: • A novel instrument for measuring photoconductivity and photocurrents of materials and devices. • Continuous parameter space: 350 nm≤λ≤1700, 1.8 K≤T≤300 K, and B≤9 T. • Methodology for treating non-linear responses and variable lamp intensity. • Mathematical detail for extracting properties of materials from measured values is provided.

  15. Rotational Raman scattering using molecular nitrogen gas for calibration of Thomson-scattering apparatus

    International Nuclear Information System (INIS)

    Yamauchi, Toshihiko; Nakazawa, Ichiro

    1987-01-01

    Anti-Stokes rotational Raman lines in molecular nitrogen gas were used for the calibration of Thomson-scattering apparatus. It was found that molecular nitrogen gas is suitable for a vessel having strong stray light. The polarization ratio was 0.16 using linear-polarized laser light. (author)

  16. Measuring and modeling intraocular light scatter with Shack-Hartmann wavefront sensing and the effects of nuclear cataract on the measurement of wavefront error

    Science.gov (United States)

    Donnelly, William J., III

    Purpose. The purpose of this research is to determine if Shack/Hartmann (S/H) wavefront sensing (SHWS) can be used to objectively quantify ocular forward scatter. Methods. Patient S/H images from an study of nuclear cataract were analyzed to extract scattering data by examining characteristics of the lenslet point spread functions. Physical and computer eye models with simulated cataract were developed to control variables and to test the underlying assumptions for using SHWS to measure aberrations and light scatter from nuclear cataract. Results. (1) For patients with nuclear opalescence (NO) >=2.5, forward scatter metrics in a multiple regression analysis account for 33% of variance in Mesopic Low Contrast acuity. Prediction of visual acuity was improved by employing a multiple regression analysis that included both backscatter and forward scatter metrics (R2 = 51%) for Mesopic High Contrast acuity. (2) The physical and computer models identified areas of instrument noise (e.g., stray light and unwanted reflections) improving the design of a second generation SHWS for measuring both wavefront error and scatter. (3) Exposure time had the most influence on, and pupil size had negligible influence on forward scatter metrics. Scatter metric MAX_SD predicted changes in simulated cataract up to R2 = 92%. There were small but significant differences (alpha = 0.05) between 1.5-pass and 1-pass wavefront measurements inclusive of variable simulated nuclear cataract and exposure; however, these differences were not visually significant. Improvements to the SHWS imaging hardware, software, and test protocol were implemented in a second generation SHWS to be used in a longitudinal cataract study. Conclusions. Forward light scatter in real eyes can be quantified using a SHWS. In the presence of clinically significant nuclear opalescence, forward scatter metrics predicted acuity better than the LOCS III NO backscatter metric. The superiority of forward scatter metrics over back

  17. Portable Instrument to Measure CDOM Light Absorption in Aquatic Systems: WPI Success Story

    Science.gov (United States)

    2001-01-01

    World Precision Instruments, Inc. (WPI), of Sarasota, FL, in collaboration with NASA's John C. Stennis Space Center, has developed an innovative instrument to accurately measure Colored Dissolved Organic Matter (CDOM) absorption in the field. This successful collaboration has culminated in an exciting new device, called the UltraPath, now commercially available through WPI. Traditional methods of measuring absorption of dissolved materials require special handling and storage prior to measurement. Use of laboratory spectrophotometers as the measuring devices have proven time consuming, cumbersome, and delicate to handle. The UltraPath provides a low-cost, highly sensitive, rugged, portable system that is capable of high sensitivity measurements in widely divergent waters.

  18. Evolution of Instrumentation for UV-Visible Spectrophotometry. Part I.

    Science.gov (United States)

    Altemose, Ines R.

    1986-01-01

    Traces the development of instruments used in spectrophotometry. Discusses how spectrophotometric measurements are made. Describes the color comparator, the filter photometer, and the spectrophotometer. Outlines the evolution of optical systems, including light sources, the monochromator, the photodetector, double-beam optics, and split-beam…

  19. Safeguards instrument to monitor spent reactor fuel

    International Nuclear Information System (INIS)

    Nicholson, N.; Dowdy, E.J.; Holt, D.M.; Stump, C.

    1981-01-01

    A hand-held instrument for monitoring irradiated nuclear fuel inventories located in water-filled storage ponds has been developed. This instrument provides sufficient precise qualitative and quantitative information to be useful as a confirmatory technique to International Atomic Energy Agency inspectors, and is believed to be of potential use to nuclear fuel managers and to operators of spent-fuel storage facilities, both at reactor and away-from-reactor, and to operators of nuclear fuel reprocessing plants. Because the Cerenkov radiation glow can barely be seen by the unaided eye under darkened conditions, a night vision device is incorporated to aid the operator in locating the fuel assembly to be measured. Beam splitting optics placed in front of the image intensifier and a preset aperture select a predetermined portion of the observed scene for measurement of the light intensity using a photomultiplier (PM) tube and digital readout. The PM tube gain is adjusted by use of an internal optical reference source, providing long term repeatability and instrument-to-instrument cnsistency. Interchangeable lenses accommodate various viewing and measuring conditions

  20. An Isotropic Light Sensor for Measurements of Visible Actinic Flux in Clouds

    NARCIS (Netherlands)

    Hage, J.C.H. van der; Roode, S.R. de

    1999-01-01

    A low-cost isotropic light sensor is described consisting of a spherical diffuser connected to a single photodiode by a light conductor. The directional response to light is isotropic to a high degree. The small, lightweight, and rugged construction makes this instrument suitable not only for

  1. Balances instruments, manufacturers, history

    CERN Document Server

    Robens, Erich; Kiefer, Susanne

    2014-01-01

    The book deals mainly with direct mass determination by means of a conventional balances. It covers the history of the balance from the beginnings in Egypt earlier than 3000 BC to recent developments. All balance types are described with emphasis on scientific balances. Methods of indirect mass determination, which are applied to very light objects like molecules and the basic particles of matter and celestial bodies, are included.  As additional guidance, today’s manufacturers are listed and the profile of important companies is reviewed. Several hundred photographs, reproductions and drawings show instruments and their uses. This book includes commercial weighing instruments for merchandise and raw materials in workshops as well as symbolic weighing in the ancient Egyptian’s ceremony of ‘Weighing of the Heart’, the Greek fate balance, the Roman  Justitia, Juno Moneta and Middle Ages scenes of the Last Judgement with Jesus or St. Michael and of modern balances. The photographs are selected from the...

  2. Development of a new instrument for the measurement of the milk constituents based on the embedded system

    International Nuclear Information System (INIS)

    Zhou Zhen; Wu Juan; Su Lijun; Li Zhonggang; Zhao Hong

    2007-01-01

    This paper presents a new way for measuring milk constituents. The new technology utilizes the scattered light to transmitted light ratio of laser light to determine the amount of protein and fat in milk. Fundamental theories of this new technology are discussed in detail and the design blueprint of an embedded system built based on this technology is outlined. Furthermore, the protein concentrations measured by the newly developed instrument are fit well with the authentic results from Dairy Quality Supervision and Inspection Center of the Country, indicating the instrument is feasible and has great potential for the application in dairy industry

  3. 75 FR 34096 - Application(s) for Duty-Free Entry of Scientific Instruments

    Science.gov (United States)

    2010-06-16

    ... University Department of Chemistry, 3501 Laclede Ave., St. Louis, MO 63103. Instrument: Electron Microscope..., enhanced thermal conductivity (lubricants), thermally stable, light-weight materials for space applications...

  4. Polarized light and optical measurement

    CERN Document Server

    Clarke, D N; Ter Haar, D

    2013-01-01

    Polarized Light and Optical Measurement is a five-chapter book that begins with a self-consistent conceptual picture of the phenomenon of polarization. Chapter 2 describes a number of interactions of light and matter used in devising optical elements in polarization studies. Specific optical elements are given in Chapter 3. The last two chapters explore the measurement of the state of polarization and the various roles played in optical instrumentation by polarization and polarization-sensitive elements. This book will provide useful information in this field of interest for research workers,

  5. Instrumentation for millisecond-resolution scattering studies

    International Nuclear Information System (INIS)

    Stephenson, G.B.; Ludwig, K.F. Jr.; Jordan-Sweet, J.L.; Brauer, S.; Mainville, J.; Yang, Y.S.; Sutton, M.

    1989-01-01

    Time-resolved x-ray scattering studies of phase transition kinetics have been carried out using the wide-bandpass monochromator and fast linear position-sensitive detector system at the IBM/MIT beamline X-20C at the National Synchrotron Light Source (NSLS). We report here on the instrumentation that has been developed for these studies, and in particular on the methods used to measure, change, and control sample temperature with millisecond resolution

  6. Sensitivity Analysis and Stray Capacitance of Helical Flux Compression Generator with Multi Layer Filamentary Conductor in Rectangular Cross-Section

    Directory of Open Access Journals (Sweden)

    M. E. Mosleh

    2012-03-01

    Full Text Available This paper presents an approach to calculate the equivalent stray capacitance (SC of n-turn of the helical flux compression generator (HFCG coil with multi layer conductor wire filaments (MLCWF in the form of rectangular cross-section. This approach is based on vespiary regular hexagonal (VRH model. In this method, wire filaments of the generator coil are separated into many very small similar elementary cells. By the expanded explosion in the liner and move explosion to the end of the liner, the coil turns number will be reduced. So, the equivalent SC of the HFCG will increase. The results show that by progress of explosion and decrease of the turns’ number in the generator coil total capacitance of the generator increases until the explosion reaches to the second turn. When only one turn remains in the circuit, a decrease occurs in the total capacitance of the generator.

  7. High power deep UV-LEDs for analytical optical instrumentation

    Czech Academy of Sciences Publication Activity Database

    Li, Y.; Dvořák, Miloš; Nesterenko, P. N.; Nuchtavorn, N.; Macka, M.

    2018-01-01

    Roč. 255, č. 2 (2018), s. 1238-1243 ISSN 0925-4005 Institutional support: RVO:68081715 Keywords : deep UV Light emitting diodes (LEDs) * optical detection * portable analytical instrumentation Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 5.401, year: 2016

  8. PARASITIC INTERFERENCE IN LONG BASELINE OPTICAL INTERFEROMETRY: REQUIREMENTS FOR HOT JUPITER-LIKE PLANET DETECTION

    International Nuclear Information System (INIS)

    Matter, A.; Lopez, B.; Lagarde, S.; Danchi, W. C.; Robbe-Dubois, S.; Petrov, R. G.; Navarro, R.

    2009-01-01

    The observable quantities in optical interferometry, which are the modulus and the phase of the complex visibility, may be corrupted by parasitic fringes superimposed on the genuine fringe pattern. These fringes are due to an interference phenomenon occurring from stray light effects inside an interferometric instrument. We developed an analytical approach to better understand this phenomenon when stray light causes cross talk between beams. We deduced that the parasitic interference significantly affects the interferometric phase and thus the associated observables including the differential phase and the closure phase. The amount of parasitic flux coupled to the piston between beams appears to be very influential in this degradation. For instance, considering a point-like source and a piston ranging from λ/500 to λ/5 in the L band (λ = 3.5 μm), a parasitic flux of about 1% of the total flux produces a parasitic phase reaching at most one-third of the intrinsic phase. The piston, which can have different origins (instrumental stability, atmospheric perturbations, etc.), thus amplifies the effect of parasitic interference. According to the specifications of piston correction in space or at ground level (respectively λ/500 ∼ 2 nm and λ/30 ∼ 100 nm), the detection of hot Jupiter-like planets, one of the most challenging aims for current ground-based interferometers, limits parasitic radiation to about 5% of the incident intensity. This was evaluated by considering different types of hot Jupiter synthetic spectra. Otherwise, if no fringe tracking is used, the detection of a typical hot Jupiter-like system with a solar-like star would admit a maximum level of parasitic intensity of 0.01% for piston errors equal to λ/15. If the fringe tracking specifications are not precisely observed, it thus appears that the allowed level of parasitic intensity dramatically decreases and may prevent the detection. In parallel, the calibration of the parasitic phase by a

  9. Non-Destructive Monitoring of Charge-Discharge Cycles on Lithium Ion Batteries using 7Li Stray-Field Imaging

    Science.gov (United States)

    Tang, Joel A.; Dugar, Sneha; Zhong, Guiming; Dalal, Naresh S.; Zheng, Jim P.; Yang, Yong; Fu, Riqiang

    2013-01-01

    Magnetic resonance imaging provides a noninvasive method for in situ monitoring of electrochemical processes involved in charge/discharge cycling of batteries. Determining how the electrochemical processes become irreversible, ultimately resulting in degraded battery performance, will aid in developing new battery materials and designing better batteries. Here we introduce the use of an alternative in situ diagnostic tool to monitor the electrochemical processes. Utilizing a very large field-gradient in the fringe field of a magnet, stray-field-imaging (STRAFI) technique significantly improves the image resolution. These STRAFI images enable the real time monitoring of the electrodes at a micron level. It is demonstrated by two prototype half-cells, graphite∥Li and LiFePO4∥Li, that the high-resolution 7Li STRAFI profiles allow one to visualize in situ Li-ions transfer between the electrodes during charge/discharge cyclings as well as the formation and changes of irreversible microstructures of the Li components, and particularly reveal a non-uniform Li-ion distribution in the graphite. PMID:24005580

  10. Two-Column Aerosol Project: Aerosol Light Extinction Measurements Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Dubey, Manvendra [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Aiken, Allison [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Berg, Larry K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Freedman, Andrew [Aerodyne Research, Inc., Billerica, MA (United States); Gorkowski, Kyle [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-01

    We deployed Aerodyne Research Inc.’s first Cavity Attenuated Phase Shift extinction (CAPS PMex) monitor (built by Aerodyne) that measures light extinction by using a visible-light-emitting diode (LED) as a light source, a sample cell incorporating two high-reflectivity mirrors centered at the wavelength of the LED, and a vacuum photodiode detector in Cape Cod in 2012/13 for the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Two-Column Aerosol Project (TCAP). The efficacy of this instrument is based on the fact that aerosols are broadband scatterers and absorbers of light. The input LED is square-wave modulated and passed through the sample cell that distorts it due to exponential decay by aerosol light absorption and scattering; this is measured at the detector. The amount of phase shift of the light at the detector is used to determine the light extinction. This extinction measurement provides an absolute value, requiring no calibration. The goal was to compare the CAPS performance with direct measurements of absorption with ARM’s baseline photoacoustic soot spectrometer (PASS-3) and nephelometer instruments to evaluate its performance.

  11. Development of ultrasonic instrument 'UT1000 Series'

    International Nuclear Information System (INIS)

    Ogura, Yukio; Ikeda, Toshimichi

    1984-01-01

    The ultrasonic flaw detectors with 'A-scope indication' have been frequently used as the means for confirming the soundness of structures and equipments, but there are problems in their operational, quantifying and recording capabilities. Recently, the digital ultrasonic measuring instrument of touch panel type ''UT 1000 Series'' has been developed, which resolves these problems by a single effort. This measuring instrument is that of portable type, which gives the digital output of measured results in real time only by lightly touching the peak point of an echo on the Brown tube. This instrument contains the rich software for measurement, and can measure the positions and dimensions of defects and the pressure on contact surfaces with high accuracy. 'A-scope indication' is the indication with an oscilloscope taking the intensity of echo and the propagation time of ultrasonic waves on the ordinate and abscissa, respectively. There are three types of the instrument, that is, for detecting defects, for measuring contact surface pressure and for both purposes. The size of the instrument is 240 mm width, 350 mm length and 175 mm height, and the weight is 8.5 kgf. The specification, function and features of the ultrasonic flaw detector, touch panel, gain setter, key board, microcomputer and others are reported. (Kako, I.)

  12. METIS: the visible and UV coronagraph for solar orbiter

    Science.gov (United States)

    Romoli, M.; Landini, F.; Antonucci, E.; Andretta, V.; Berlicki, A.; Fineschi, S.; Moses, J. D.; Naletto, G.; Nicolosi, P.; Nicolini, G.; Spadaro, D.; Teriaca, L.; Baccani, C.; Focardi, M.; Pancrazzi, M.; Pucci, S.; Abbo, L.; Bemporad, A.; Capobianco, G.; Massone, G.; Telloni, D.; Magli, E.; Da Deppo, V.; Frassetto, F.; Pelizzo, M. G.; Poletto, L.; Uslenghi, M.; Vives, S.; Malvezzi, M.

    2017-11-01

    METIS coronagraph is designed to observe the solar corona with an annular field of view from 1.5 to 2.9 degrees in the visible broadband (580-640 nm) and in the UV HI Lyman-alpha, during the Sun close approaching and high latitude tilting orbit of Solar Orbiter. The big challenge for a coronagraph is the stray light rejection. In this paper after a description of the present METIS optical design, the stray light rejection design is presented in detail together with METIS off-pointing strategies throughout the mission. Data shown in this paper derive from the optimization of the optical design performed with Zemax ray tracing and from laboratory breadboards of the occultation system and of the polarimeter.

  13. Calculated Hanle transmission and absorption spectra of the 87Rb D1 line with residual magnetic field for arbitrarily polarized light

    International Nuclear Information System (INIS)

    Noh, Heung-Ryoul; Moon, Han Seb

    2010-01-01

    This paper reports a theoretical study on the transmission spectra of an arbitrarily polarized laser beam through a rubidium cell with or without a buffer gas in Hanle-type coherent population trapping (CPT). This study examined how laser polarization, transverse magnetic field, and collisions with buffer gas affects the spectrum. The transmission spectrum due to CPT and the absorption spectrum due to the level crossing absorption (LCA) were calculated according to the laser polarization. The results show that the LCA is strongly dependent on the transverse magnetic field and interaction time of the atoms with a laser light via collisions with the buffer gas. In addition, the spectral shape of the calculated Hanle spectrum is closely related to the direction between the (stray) transverse magnetic field and polarization of the laser.

  14. Cold vacuum chamber for diagnostics: Instrumentation and first results

    Directory of Open Access Journals (Sweden)

    S. Gerstl

    2014-10-01

    Full Text Available For a proper design of the cryogenic layout of superconducting insertion devices it is necessary to take into account the heat load from the beam to the cold beam tube. In order to measure and possibly understand the beam heat load to a cold bore, a cold vacuum chamber for diagnostics (COLDDIAG has been built. COLDDIAG is designed in a flexible way, to allow its installation in different light sources. In order to study the beam heat load and the influence of the cryosorbed gas layer, the instrumentation comprises temperature sensors, pressure gauges, and mass spectrometers as well as retarding field analyzers with which it is possible to measure the beam heat load, total pressure, and gas content as well as the flux of particles hitting the chamber walls. In this paper we describe the experimental equipment, the installation of COLDDIAG in the Diamond Light Source and selected examples of the measurements performed to show the capabilities of this unique instrument.

  15. Cold vacuum chamber for diagnostics: Instrumentation and first results

    Science.gov (United States)

    Gerstl, S.; Voutta, R.; Casalbuoni, S.; Grau, A. W.; Holubek, T.; de Jauregui, D. Saez; Bartolini, R.; Cox, M. P.; Longhi, E. C.; Rehm, G.; Schouten, J. C.; Walker, R. P.; Sikler, G.; Migliorati, M.; Spataro, B.

    2014-10-01

    For a proper design of the cryogenic layout of superconducting insertion devices it is necessary to take into account the heat load from the beam to the cold beam tube. In order to measure and possibly understand the beam heat load to a cold bore, a cold vacuum chamber for diagnostics (COLDDIAG) has been built. COLDDIAG is designed in a flexible way, to allow its installation in different light sources. In order to study the beam heat load and the influence of the cryosorbed gas layer, the instrumentation comprises temperature sensors, pressure gauges, and mass spectrometers as well as retarding field analyzers with which it is possible to measure the beam heat load, total pressure, and gas content as well as the flux of particles hitting the chamber walls. In this paper we describe the experimental equipment, the installation of COLDDIAG in the Diamond Light Source and selected examples of the measurements performed to show the capabilities of this unique instrument.

  16. Distributed Framework for Dynamic Telescope and Instrument Control

    Science.gov (United States)

    Ames, Troy J.; Case, Lynne

    2002-01-01

    Traditionally, instrument command and control systems have been developed specifically for a single instrument. Such solutions are frequently expensive and are inflexible to support the next instrument development effort. NASA Goddard Space Flight Center is developing an extensible framework, known as Instrument Remote Control (IRC) that applies to any kind of instrument that can be controlled by a computer. IRC combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML). A key aspect of the architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). IML is an XML dialect used to describe graphical user interfaces to control and monitor the instrument, command sets and command formats, data streams, communication mechanisms, and data processing algorithms. The IRC framework provides the ability to communicate to components anywhere on a network using the JXTA protocol for dynamic discovery of distributed components. JXTA (see httD://www.jxta.org,) is a generalized protocol that allows any devices connected by a network to communicate in a peer-to-peer manner. IRC uses JXTA to advertise a device's IML and discover devices of interest on the network. Devices can join or leave the network and thus join or leave the instrument control environment of IRC. Currently, several astronomical instruments are working with the IRC development team to develop custom components for IRC to control their instruments. These instruments include: High resolution Airborne Wideband Camera (HAWC), a first light instrument for the Stratospheric Observatory for Infrared Astronomy (SOFIA); Submillimeter And Far Infrared Experiment (SAFIRE), a Principal Investigator instrument for SOFIA; and Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE), a prototype of the SAFIRE instrument, used at the Caltech Submillimeter Observatory (CSO). Most recently, we have

  17. Regulatory instrument review: Management of aging of LWR [light water reactor] major safety-related components

    International Nuclear Information System (INIS)

    Werry, E.V.

    1990-10-01

    This report comprises Volume 1 of a review of US nuclear plant regulatory instruments to determine the amount and kind of information they contain on managing the aging of safety-related components in US nuclear power plants. The review was conducted for the US Nuclear Regulatory Commission (NRC) by the Pacific Northwest Laboratory (PNL) under the NRC Nuclear Plant Aging Research (NPAR) Program. Eight selected regulatory instruments, e.g., NRC Regulatory Guides and the Code of Federal Regulations, were reviewed for safety-related information on five selected components: reactor pressure vessels, steam generators, primary piping, pressurizers, and emergency diesel generators. Volume 2 will be concluded in FY 1991 and will also cover selected major safety-related components, e.g., pumps, valves and cables. The focus of the review was on 26 NPAR-defined safety-related aging issues, including examination, inspection, and maintenance and repair; excessive/harsh testing; and irradiation embrittlement. The major conclusion of the review is that safety-related regulatory instruments do provide implicit guidance for aging management, but include little explicit guidance. The major recommendation is that the instruments be revised or augmented to explicitly address the management of aging

  18. Instrumentation in Developing Chlorophyll Fluorescence Biosensing: A Review

    Science.gov (United States)

    Fernandez-Jaramillo, Arturo A.; Duarte-Galvan, Carlos; Contreras-Medina, Luis M.; Torres-Pacheco, Irineo; de J. Romero-Troncoso, Rene; Guevara-Gonzalez, Ramon G.; Millan-Almaraz, Jesus R.

    2012-01-01

    Chlorophyll fluorescence can be defined as the red and far-red light emitted by photosynthetic tissue when it is excited by a light source. This is an important phenomenon which permits investigators to obtain important information about the state of health of a photosynthetic sample. This article reviews the current state of the art knowledge regarding the design of new chlorophyll fluorescence sensing systems, providing appropriate information about processes, instrumentation and electronic devices. These types of systems and applications can be created to determine both comfort conditions and current problems within a given subject. The procedure to measure chlorophyll fluorescence is commonly split into two main parts; the first involves chlorophyll excitation, for which there are passive or active methods. The second part of the procedure is to closely measure the chlorophyll fluorescence response with specialized instrumentation systems. Such systems utilize several methods, each with different characteristics regarding to cost, resolution, ease of processing or portability. These methods for the most part include cameras, photodiodes and satellite images. PMID:23112686

  19. Instrumentation in Developing Chlorophyll Fluorescence Biosensing: A Review

    Directory of Open Access Journals (Sweden)

    Jesus R. Millan-Almaraz

    2012-08-01

    Full Text Available Chlorophyll fluorescence can be defined as the red and far-red light emitted by photosynthetic tissue when it is excited by a light source. This is an important phenomenon which permits investigators to obtain important information about the state of health of a photosynthetic sample. This article reviews the current state of the art knowledge regarding the design of new chlorophyll fluorescence sensing systems, providing appropriate information about processes, instrumentation and electronic devices. These types of systems and applications can be created to determine both comfort conditions and current problems within a given subject. The procedure to measure chlorophyll fluorescence is commonly split into two main parts; the first involves chlorophyll excitation, for which there are passive or active methods. The second part of the procedure is to closely measure the chlorophyll fluorescence response with specialized instrumentation systems. Such systems utilize several methods, each with different characteristics regarding to cost, resolution, ease of processing or portability. These methods for the most part include cameras, photodiodes and satellite images.

  20. Nanostructure Secondary-Mirror Apodizing Mask for Transmitter Signal Suppression in a Duplex Telescope

    Science.gov (United States)

    Hagopian, John; Livas, Jeffrey; Shiri, Shahram; Getty, Stephanie; Tveekrem, June; Butler, James

    2012-01-01

    A document discusses a nanostructure apodizing mask, made of multi-walled carbon nanotubes, that is applied to the centers (or in and around the holes) of the secondary mirrors of telescopes that are used to interferometrically measure the strain of space-time in response to gravitational waves. The shape of this ultra-black mask can be adjusted to provide a smooth transition to the clear aperture of the secondary mirror to minimize diffracted light. Carbon nanotubes grown on silicon are a viable telescope mirror substrate, and can absorb significantly more light than other black treatments. The hemispherical reflectance of multi-walled carbon nanotubes grown at GSFC is approximately 3 to 10 times better than a standard aerospace paint used for stray light control. At the LISA (Laser Interferometer Space Antenna) wavelength of 1 micron, the advantage over paint is a factor of 10. Primarily, in the center of the secondary mirror (in the region of central obscuration, where no received light is lost) a black mask is applied to absorb transmitted light that could be reflected back into the receiver. In the LISA telescope, this is in the center couple of millimeters. The shape of this absorber is critical to suppress diffraction at the edge. By using the correct shape, the stray light can be reduced by approximately 10 to the 9 orders of magnitude versus no center mask. The effect of the nanotubes has been simulated in a stray-light model. The effect of the apodizing mask has been simulated in a near-field diffraction model. Specifications are geometry-dependent, but the baseline design for the LISA telescope has been modeled as well. The coatings are somewhat fragile, but work is continuing to enhance adhesion.

  1. Development of a surface topography instrument for automotive textured steel plate

    Science.gov (United States)

    Wang, Zhen; Wang, Shenghuai; Chen, Yurong; Xie, Tiebang

    2010-08-01

    The surface topography of automotive steel plate is decisive to its stamping, painting and image clarity performances. For measuring this kind of surface topography, an instrument has been developed based on the principle of vertical scanning white light microscopy interference principle. The microscopy interference system of this instrument is designed based on the structure of Linnik interference microscopy. The 1D worktable of Z direction is designed and introduced in details. The work principle of this instrument is analyzed. In measuring process, the interference microscopy is derived as a whole and the measured surface is scanned in vertical direction. The measurement accuracy and validity is verified by templates. Surface topography of textured steel plate is also measured by this instrument.

  2. Gas Detection Instrument Based on Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    ANSONG FENG

    2013-06-01

    Full Text Available The wireless sensor network is used to simulate poisonous gas generating system in the Fire-Fighting Simulated Training System. In the paper, we use the wireless signal to simulate the poisonous gas source and use received signal strength indicator (RSSI to simulate the distance between the fireman and the gas source. The gas detection instrument samples the temperature and sphygmus of the trainee and uses the wireless signal as poisonous gas signal. When the trainee enters into the poisonous gas area, the gas detection instrument warns with sound and light and sends the type, density value, the location of the poisonous gas and vital signs of the trainee to host. The paper discusses the software and hardware design of the gas detection instrument. The system has been used to the several of Fire-Fighting training systems.

  3. Radiofrequency encoded angular-resolved light scattering

    DEFF Research Database (Denmark)

    Buckley, Brandon W.; Akbari, Najva; Diebold, Eric D.

    2015-01-01

    The sensitive, specific, and label-free classification of microscopic cells and organisms is one of the outstanding problems in biology. Today, instruments such as the flow cytometer use a combination of light scatter measurements at two distinct angles to infer the size and internal complexity...... of cells at rates of more than 10,000 per second. However, by examining the entire angular light scattering spectrum it is possible to classify cells with higher resolution and specificity. Current approaches to performing these angular spectrum measurements all have significant throughput limitations...... Encoded Angular-resolved Light Scattering (REALS), this technique multiplexes angular light scattering in the radiofrequency domain, such that a single photodetector captures the entire scattering spectrum from a particle over approximately 100 discrete incident angles on a single shot basis. As a proof...

  4. Design and performance of an ultraviolet resonance Raman spectrometer for proteins and nucleic acids.

    Science.gov (United States)

    Russell, M P; Vohník, S; Thomas, G J

    1995-04-01

    We describe an ultraviolet resonance Raman (UVRR) spectrometer appropriate for structural studies of biological macromolecules and their assemblies. Instrument design includes the following features: a continuous wave, intracavity doubled, ultraviolet laser source for excitation of the Raman spectrum; a rotating cell (or jet source) for presentation of the sample to the laser beam; a Cassegrain optic with f/1.0 aperture for collection of the Raman scattering; a quartz prism dispersing element for rejection of stray light and Rayleigh scattering; a 0.75-m single grating monochromator for dispersion of the Raman scattering; and a liquid-nitrogen-cooled, charge-coupled device for detection of the Raman photons. The performance of this instrument, assessed on the basis of the observed signal-to-noise ratios, the apparent resolution of closely spaced spectral bands, and the wide spectrometer bandpass of 2200 cm-1, is believed superior to previously described UVRR spectrometers of similar design. Performance characteristics of the instrument are demonstrated in UVRR spectra obtained from standard solvents, p-ethylphenol, which serves as a model for the tyrosine side chain, the DNA nucleotide deoxyguanosine-5'-monophosphate, and the human tumor necrosis factor binding protein, which is considered representative of soluble globular proteins.

  5. Advanced Light Source beam position monitor

    International Nuclear Information System (INIS)

    Hinkson, J.

    1991-01-01

    The Advanced Light Source (ALS) is a synchrotron radiation facility nearing completion at LBL. As a third-generation machine, the ALS is designed to produce intense light from bend magnets, wigglers, and undulators (insertion devices). The facility will include a 50 MeV electron linear accelerator, a 1.5 GeV booster synchrotron, beam transport lines, a 1--2 GeV storage ring, insertion devices, and photon beam lines. Currently, the beam injection systems are being commissioned, and the storage ring is being installed. Electron beam position monitors (BPM) are installed throughout the accelerator and constitute the major part of accelerator beam diagnostics. The design of the BPM instruments is complete, and 50 units have been constructed for use in the injector systems. We are currently fabricating 100 additional instruments for the storage ring. In this paper I discuss engineering fabrication, testing and performance of the beam pickup electrodes and the BPM electronics

  6. Reliability of Instruments Measuring At-Risk and Problem Gambling Among Young Individuals

    DEFF Research Database (Denmark)

    Edgren, Robert; Castrén, Sari; Mäkelä, Marjukka

    2016-01-01

    This review aims to clarify which instruments measuring at-risk and problem gambling (ARPG) among youth are reliable and valid in light of reported estimates of internal consistency, classification accuracy, and psychometric properties. A systematic search was conducted in PubMed, Medline, and Psyc......Info covering the years 2009–2015. In total, 50 original research articles fulfilled the inclusion criteria: target age under 29 years, using an instrument designed for youth, and reporting a reliability estimate. Articles were evaluated with the revised Quality Assessment of Diagnostic Accuracy Studies tool....... Reliability estimates were reported for five ARPG instruments. Most studies (66%) evaluated the South Oaks Gambling Screen Revised for Adolescents. The Gambling Addictive Behavior Scale for Adolescents was the only novel instrument. In general, the evaluation of instrument reliability was superficial. Despite...

  7. EVEREST: Pixel Level Decorrelation of K2 Light Curves

    Science.gov (United States)

    Luger, Rodrigo; Agol, Eric; Kruse, Ethan; Barnes, Rory; Becker, Andrew; Foreman-Mackey, Daniel; Deming, Drake

    2016-10-01

    We present EPIC Variability Extraction and Removal for Exoplanet Science Targets (EVEREST), an open-source pipeline for removing instrumental noise from K2 light curves. EVEREST employs a variant of pixel level decorrelation to remove systematics introduced by the spacecraft’s pointing error and a Gaussian process to capture astrophysical variability. We apply EVEREST to all K2 targets in campaigns 0-7, yielding light curves with precision comparable to that of the original Kepler mission for stars brighter than {K}p≈ 13, and within a factor of two of the Kepler precision for fainter targets. We perform cross-validation and transit injection and recovery tests to validate the pipeline, and compare our light curves to the other de-trended light curves available for download at the MAST High Level Science Products archive. We find that EVEREST achieves the highest average precision of any of these pipelines for unsaturated K2 stars. The improved precision of these light curves will aid in exoplanet detection and characterization, investigations of stellar variability, asteroseismology, and other photometric studies. The EVEREST pipeline can also easily be applied to future surveys, such as the TESS mission, to correct for instrumental systematics and enable the detection of low signal-to-noise transiting exoplanets. The EVEREST light curves and the source code used to generate them are freely available online.

  8. Instrumentation for the study of low emittance tuning and beam dynamics at CESR

    Science.gov (United States)

    Billing, M. G.; Dobbins, J. A.; Forster, M. J.; Kreinick, D. L.; Meller, R. E.; Peterson, D. P.; Ramirez, G. A.; Rendina, M. C.; Rider, N. T.; Sagan, D. C.; Shanks, J.; Sikora, J. P.; Stedinger, M. G.; Strohman, C. R.; Williams, H. A.; Palmer, M. A.; Holtzapple, R. L.; Flanagan, J.

    2017-11-01

    The Cornell Electron-positron Storage Ring (CESR) has been converted from a High Energy Physics electron-positron collider to operate as a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS) and to conduct accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Some of the specific topics that were targeted for the initial phase of operation of the storage ring in this mode for CESR as a Test Accelerator (CesrTA) included 1) tuning techniques to produce low emittance beams, 2) the study of electron cloud development in a storage ring and 3) intra-beam scattering effects. The complete conversion of CESR to CesrTA occurred over a several year period, described elsewhere [1-3]. In addition to instrumentation for the storage ring, which was created for CesrTA, existing instrumentation was modified to facilitate the entire range of investigations to support these studies. Procedures were developed, often requiring coordinated measurements among different instruments [4]. This paper describes the instruments utilized for the study of beam dynamics during the operation of CesrTA. The treatment of these instruments will remain fairly general in this paper as it focusses on an overview of the instruments themselves. Their interaction and inter-relationships during sequences of observations is found in a companion paper describing the associated measurement techniques. More detailed descriptions and detailed operational performance for some of the instrumentation may be found elsewhere and these will be referenced in the related sections of this paper.

  9. Precollimator Manufacturing for X-ray Telescopes, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Space-based x-ray telescopes currently involve the use of a precollimator (PC) to shield the optics from stray light. Each PC consists of cylindrical aluminum ribs...

  10. Detection of small number of Giardia in biological materials prepared from stray dogs.

    Science.gov (United States)

    Esmailikia, Leila; Ebrahimzade, Elahe; Shayan, Parviz; Amininia, Narges

    2017-12-20

    Giardia lamblia is an intestinal protozoa with intermittent and low shedding especially in dogs, and the detection of Giardia is accompanied with problems such as sampling and diagnostic method. The objective of this study was to detection of Giardia in biological materials with low number of parasite using parasitological and molecular methods, and also to determine whether the examined stray dogs harbor known zoonotic genotype of Giardia. For this aim 85 fecal and duodenal samples were studied from which 1 was positive by Trichrome staining of stool, 4 were positive by staining of duodenal samples. The nested PCR analysis with primers derived from 18 SrRNA showed that the specific PCR product could be amplified in 4 stool and 4 duodenal samples. All positive samples in staining analysis were also positive in nested PCR. No amplification could be observed by nested PCR with primers derived from β giardin gene due to the single copy of gene. Interestingly, the extracted DNA from old fixed stained Giardia positive smears could be also amplified with primers derived from 18SrRNA gene. The sequence analysis of nested PCR products showed that they belong to the genotype D. In conclusion, it is to denote that the Trichrome or Giemsa methods were not suitable for the detection of small number of this parasite in stool and the nested PCR with primers derived from 18S rRNA gene can replace the traditional methods successfully. For detection of Giardia in stool, primers derived from β giardin will not be recommended.

  11. An instrument for the high-statistics measurement of plastic scintillating fibers

    International Nuclear Information System (INIS)

    Buontempo, S.; Ereditato, A.; Marchetti-Stasi, F.; Riccardi, F.; Strolin, P.

    1994-01-01

    There is today widespread use of plastic scintillating fibers in particle physics, mainly for calorimetric and tracking applications. In the case of calorimeters, we have to cope with very massive detectors and a large quantity of scintillating fibers. The CHORUS Collaboration has built a new detector to search for ν μ -ν τ oscillations in the CERN neutrino beam. A crucial task of the detector is ruled by the high-energy resolution calorimeter. For its construction more than 400 000 scintillating plastic fibers have been used. In this paper we report on the design and performance of a new instrument for the high-statistics measurement of the fiber properties, in terms of light yield and light attenuation length. The instrument has been successfully used to test about 3% of the total number of fibers before the construction of the calorimeter. ((orig.))

  12. Satellite instrument provides nighttime sensing capability

    Science.gov (United States)

    Showstack, Randy

    2012-12-01

    "This is not your father's low-light sensor," Steve Miller, senior research scientist and deputy director of the Cooperative Institute for Research in the Atmosphere at Colorado State University, Fort Collins, said at a 5 December news briefing at the AGU Fall Meeting. He and others at the briefing were showing off the nighttime sensing capability of the day/night band of the Visible Infrared Imaging Radiometer Suite (VIIRS) of instruments onboard the Suomi National Polar-orbiting Partnership (NPP) Earth-observing research satellite, a joint NASA and National Oceanic and Atmospheric Administration (NOAA) satellite that was launched on 28 October 2011. Noting that low-light satellite technology has been available for about 40 years, Miller said that the VIIRS day/night band "is truly a paradigm shift in the technology and capability."

  13. System 80+ instrumentation and controls - certification of a reliable design

    International Nuclear Information System (INIS)

    Matzie, R.A.; Scarola, K.; Turk, R.S.

    1993-01-01

    ABB Combustion Engineering's (ABB) System 80+ advanced light water plant design includes a modern, fully digitized instrumentation and controls complex, Nuplex 80+. This complex incorporates an evolutionary advanced control room, replacing conventional analog instruments with more capable computer driven components. As a result, Nuplex 80+ results in significant improvements in operator information handling and control to enhance plant safety and availability. The design implements features which the U.S. NRC has determined to be acceptable for addressing the potential for common mode failure in software implemented for protective functions. (author)

  14. Typical effects of laser dazzling CCD camera

    Science.gov (United States)

    Zhang, Zhen; Zhang, Jianmin; Shao, Bibo; Cheng, Deyan; Ye, Xisheng; Feng, Guobin

    2015-05-01

    In this article, an overview of laser dazzling effect to buried channel CCD camera is given. The CCDs are sorted into staring and scanning types. The former includes the frame transfer and interline transfer types. The latter includes linear and time delay integration types. All CCDs must perform four primary tasks in generating an image, which are called charge generation, charge collection, charge transfer and charge measurement. In camera, the lenses are needed to input the optical signal to the CCD sensors, in which the techniques for erasing stray light are used. And the electron circuits are needed to process the output signal of CCD, in which many electronic techniques are used. The dazzling effects are the conjunct result of light distribution distortion and charge distribution distortion, which respectively derive from the lens and the sensor. Strictly speaking, in lens, the light distribution is not distorted. In general, the lens are so well designed and fabricated that its stray light can be neglected. But the laser is of much enough intensity to make its stray light obvious. In CCD image sensors, laser can induce a so large electrons generation. Charges transfer inefficiency and charges blooming will cause the distortion of the charge distribution. Commonly, the largest signal outputted from CCD sensor is restricted by capability of the collection well of CCD, and can't go beyond the dynamic range for the subsequent electron circuits maintaining normal work. So the signal is not distorted in the post-processing circuits. But some techniques in the circuit can make some dazzling effects present different phenomenon in final image.

  15. OSIRIS (Observing System Including PolaRisation in the Solar Infrared Spectrum) instrument: a multi-directional, polarized radiometer in the visible and shortwave infrared, airborne prototype of 3MI / EPS-SG Eumetsat - ESA mission

    Science.gov (United States)

    Matar, C.; Auriol, F.; Nicolas, J. M.; Parol, F.; Riedi, J.; Djellali, M. S.; Cornet, C.; Waquet, F.; Catalfamo, M.; Delegove, C.; Loisil, R.

    2017-12-01

    OSIRIS instrument largely inherits from the POLDER concept developed and operated between 1991 (first airborne prototype) and 2013 (end of the POLDER-3/PARASOL space-borne mission). It consists in two optical systems, one covering the visible to near infrared range (440, 490, 670, 763, 765, 870, 910 and 940 nm) and a second one for the shortwave infrared (940, 1020, 1240, 1360, 1620 and 2200 nm). Each optical system is composed of a wide field-of-view optics (114° and 105° respectively) associated to two rotating wheels with interferential filters (spectral) and analyzers filters (polarization) respectively, and a 2D array of detectors. For each channel, radiance is measured once without analyzer, followed by sequential measurements with the three analyzers shifted by an angle of 60° to reconstruct the total and polarized radiances. The complete acquisition sequence for all spectral channels last a couple of seconds according to the chosen measurement protocol. Thanks to the large field of view of the optics, any target is seen under several viewing angles during the aircraft motion. In a first step we will present the new ground characterization of the instrument based on laboratory measurements (linearity, flat-field, absolute calibration, induced polarization, polarizers efficiency and position), the radiometric model and the Radiometric Inverted Model (RIM) used to develop the Level 1 processing chain that is used to produce level 1 products (normalized radiances, polarized or not, with viewing geometries) from the instrument generated level 0 files (Digital Counts) and attitude information from inertial system. The stray light issues will be specifically discussed. In a second step we will present in-flight radiometric and geometric methods applied to OSIRIS data in order to control and validate ground-based calibrated products: molecular scattering method and sun-glint cross-band method for radiometric calibration, glories, rainbows and sun-glint targets

  16. Development of multifunctional radiation monitoring instrument based on PLC technology

    International Nuclear Information System (INIS)

    Li Ziqiang; Zhu Yuye; Zhuang Min

    2007-01-01

    This eight-channel multifunctional Radiation Monitoring Instrument is developed by making use of the built-in high-speed counters and the powerful instruction system of the SIEMES SIMATICS S7 series Programmable Logic Controllers (PLC) to record and process the pulse signal output by the detectors. The instrument with functions, such as analog and digital display, digital storage of digital data, pulse signal generator, network communication, can connect various types of pulse detectors. The initial process can be translated between Graduation Apparatus method and Formula method. the logicality of the high-dosage warning system is processed itself. The signal output will drive the alarm lights and bell directly. This paper mainly describes the configuration, programming and feature of the instrument. (authors)

  17. Photoacoustic and filter measurements related to aerosol light absorption during the Northern Front Range Air Quality Study (Colorado 1996/1997)

    Science.gov (United States)

    Moosmüller, H.; Arnott, W. P.; Rogers, C. F.; Chow, J. C.; Frazier, C. A.; Sherman, L. E.; Dietrich, D. L.

    1998-11-01

    A new photoacoustic instrument for the measurement of aerosol light absorption was collocated with conventional aerosol instrumentation during the 1996-1997 winter intensive monitoring period of the Northern Front Range Air Quality Study. Measurements of the light absorption efficiency for black carbon were 5 m2/g at 685 nm and 10 m2/g at 532 nm, and for elemental carbon, they were 3.6 m2/g at 685 nm. We show that these values together with previous photoacoustic measurements of aerosol light absorption shed some light on the wavelength dependence of absorption efficiency for carbonaceous aerosol in the visible and near-visible region. Integrating plate type filter measurements of aerosol light absorption result in far larger values than those measured with the photoacoustic instrument. We demonstrate that a recently published correction technique [Horvath, 1997] can yield improved agreement.

  18. Technology development, climate and use of instruments; Teknologiutvikling, klima og virkemiddelbruk

    Energy Technology Data Exchange (ETDEWEB)

    Bye, Brita; Faehn, Taran; Heggedal, Tom-Reiel; Hatlen, Liv Mari

    2009-06-15

    This report sheds light on our technology as a driving force for growth and welfare and the importance technology in particular can have on the climate area. We explain the optimal use of policy instruments to stimulate technology development on climate and energy area, the extent to which the assessment of the use of instruments will be different for this field than for technology in general, and the importance interaction with other climate policy instruments will have. The report is based on existing international literature on this subject, and explain the relevant Norwegian analysis. We emphasize the situation of a small open country like Norway and the role national technology policy can have. (Author)

  19. Thermal architecture of the SPICA/SAFARI instrument

    Science.gov (United States)

    Charles, Ivan; Duband, Lionel; Duval, Jean-Marc; Jackson, Brian; Jellema, Willem; Kooijman, Peter Paul; Luchier, Nicolas; Tirolien, Thierry; van Weers, Henk

    2012-09-01

    The SAFARI instrument is a far infrared imaging spectrometer that is a core instrument of the SPICA mission. Thanks to the large (3 meter) SPICA cold telescope, the ultra sensitive detectors and a powerful Fourier Transform Spectrometer, this instrument will give access to the faintest light never observed in the 34 μm - 210 μm bandwidth with a high spectral resolution. To achieve this goal, TES detectors, that need to be cooled at a temperature as low as 50 mK, have been chosen. The thermal architecture of the SAFARI focal plane unit (FPU) which fulfils the TES detector thermal requirements is presented. In particular, an original 50 mK cooler concept based on a sorption cooler in series with an adiabatic demagnetization refrigerator will be used. The thermal design of the detector focal plane array (FPA) that uses three temperature stages to limit the loads on the lowest temperature stage, will be also described. The current SAFARI thermal budget estimations are presented and discussed regarding the limited SPICA allocations. Finally, preliminary thermal sensitivity analysis dealing with thermal stability requirements is presented.

  20. Classification of ASKAP Vast Radio Light Curves

    Science.gov (United States)

    Rebbapragada, Umaa; Lo, Kitty; Wagstaff, Kiri L.; Reed, Colorado; Murphy, Tara; Thompson, David R.

    2012-01-01

    The VAST survey is a wide-field survey that observes with unprecedented instrument sensitivity (0.5 mJy or lower) and repeat cadence (a goal of 5 seconds) that will enable novel scientific discoveries related to known and unknown classes of radio transients and variables. Given the unprecedented observing characteristics of VAST, it is important to estimate source classification performance, and determine best practices prior to the launch of ASKAP's BETA in 2012. The goal of this study is to identify light curve characterization and classification algorithms that are best suited for archival VAST light curve classification. We perform our experiments on light curve simulations of eight source types and achieve best case performance of approximately 90% accuracy. We note that classification performance is most influenced by light curve characterization rather than classifier algorithm.

  1. LAr instrumentation for Gerda phase II

    Energy Technology Data Exchange (ETDEWEB)

    Wegmann, Anne [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2015-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay of {sup 76}Ge. Results of Phase I have been published in summer 2013. Currently the commissioning of Gerda Phase II is ongoing. To reach the aspired background index of ≤10{sup -3} cts/(keV.kg.yr) active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). It has been demonstrated by the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. The light instrumentation consisting of photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon multipliers (SiPM) has been installed in Gerda. In this talk the low background design of the LAr veto and its performance during the commissioning runs are reported.

  2. Toxoplasma gondii, Dirofilaria immitis, feline immunodeficiency virus (FIV), and feline leukemia virus (FeLV) infections in stray and pet cats (Felis catus) in northwest China: co-infections and risk factors.

    Science.gov (United States)

    Cong, Wei; Meng, Qing-Feng; Blaga, Radu; Villena, Isabelle; Zhu, Xing-Quan; Qian, Ai-Dong

    2016-01-01

    This study was conducted to estimate the prevalence of Toxoplasma gondii, Dirofilaria immitis, feline immunodeficiency virus (FIV), and feline leukemia virus (FeLV) infections among stray and pet cats in Lanzhou, northwest China, and to identify the influence of age, gender, and regions on seropositivity. T. gondii antibodies were examined in cat sera by the modified agglutination test (MAT). The circulating antigens of D. immitis and FeLV and specific antibodies to FIV were examined using kits commercially available. The overall prevalence of T. gondii, FIV, FeLV, and D. immitis was 19.34, 9.12, 11.33, and 3.04 %, respectively. For the genetic characterization of T. gondii genotypes in cats, genomic DNA was extracted from the seropositive cats and the T. gondii B1 gene was amplified using a semi-nested PCR. DNA samples giving positive B1 amplification were then genotyped using multilocus PCR-RFLP. Two T. gondii genotypes (ToxoDB#9 and ToxoDB#1) were identified. Results of the multivariate logistic regression analysis showed that older cats are more likely to be seropositive than juveniles for T. gondii, FIV, FeLV, and D. immitis. This is the first report of T. gondii genotypes in cats in northwest China. Moreover, the present study is the first study of retrovirus and D. immitis seroprevalence in cats in China. The results revealed that T. gondii, FIV, and FeLV infections are common in stray and pet cats in northwest China.

  3. Proposal for a Universal Test Mirror for Characterization of Slope Measuring Instruments

    International Nuclear Information System (INIS)

    Yashchuk, Valeriy V.; McKinney, Wayne R.; Warwick, Tony; Noll, Tino; Siewert, Frank; Zeschke, Thomas; Geckeler, Ralf D.

    2007-01-01

    The development of third generation light sources like the Advanced Light Source (ALS) or BESSY II brought to a focus the need for high performance synchrotron optics with unprecedented tolerances for slope error and micro roughness. Proposed beam lines at Free Electron Lasers (FEL) require optical elements up to a length of one meter, characterized by a residual slope error in the range of 0.1mu rad (rms),and rms values of 0.1 nm for micro roughness. These optical elements must be inspected by highly accurate measuring instruments, providing a measurement uncertainty lower than the specified accuracy of the surface under test. It is essential that metrology devices in use at synchrotron laboratories be precisely characterized and calibrated to achieve this target. In this paper we discuss a proposal for a Universal Test Mirror (UTM) as a realization of a high performance calibration instrument. The instrument would provide an ideal calibration surface to replicate a redundant surface under test of redundant figure. The application of a sophisticated calibration instrument will allow the elimination of the majority of the systematic error from the error budget of an individual measurement of a particular optical element. We present the limitations of existing methods, initial UTM design considerations, possible calibration algorithms, and an estimation of the expected accuracy

  4. The measurements of light high-energy ions in NINA-2 experiment

    Directory of Open Access Journals (Sweden)

    A. Leonov

    2007-10-01

    Full Text Available The flux of energetic light ions at low altitude is both an important input and output for self-consistent calculations of albedo particles resulting from the interaction of trapped and cosmic ray particles, with the upper atmosphere. In addition, data on the flux of light ions are needed to evaluate radiation damages on space-borne instruments and on space mission crews. In spite of that, sources of data on the flux of energetic ions at LEO are roughly limited to the AP-8 model, CREME/CREME96 codes and the SAMPEX, NOAA/TIROS satellites. The existing and operational European SAC-C/ICARE and PROBA-1/SREM instruments could also be potential sources for proton data at LEO. Although AP-8 and SAMPEX/PSB97 may be publicly accessed through the SPENVIS, they exhibit an order of magnitude difference in low altitude proton fluxes and they do not contain helium fluxes. Therefore, improved light ion radiation models are still needed.

    In this paper we present a procedure to identify and measure the energy of ions that are not stopped in the NINA-2 instrument. Moreover, problems related to particles that cross the instrument in the opposite direction are addressed and shown to be a possible cause of particle misidentification. Measuring fluxes of low abundance elements like energetic helium ions requires a good characterisation of all possible sources of backgrounds in the detector. Hints to determine the several contributions to the background are presented herein and may be applied to extract an order of magnitude of energetic ions fluxes from existing data sets, while waiting for dedicated high performance instruments.

  5. The measurements of light high-energy ions in NINA-2 experiment

    Directory of Open Access Journals (Sweden)

    A. Leonov

    2007-10-01

    Full Text Available The flux of energetic light ions at low altitude is both an important input and output for self-consistent calculations of albedo particles resulting from the interaction of trapped and cosmic ray particles, with the upper atmosphere. In addition, data on the flux of light ions are needed to evaluate radiation damages on space-borne instruments and on space mission crews. In spite of that, sources of data on the flux of energetic ions at LEO are roughly limited to the AP-8 model, CREME/CREME96 codes and the SAMPEX, NOAA/TIROS satellites. The existing and operational European SAC-C/ICARE and PROBA-1/SREM instruments could also be potential sources for proton data at LEO. Although AP-8 and SAMPEX/PSB97 may be publicly accessed through the SPENVIS, they exhibit an order of magnitude difference in low altitude proton fluxes and they do not contain helium fluxes. Therefore, improved light ion radiation models are still needed. In this paper we present a procedure to identify and measure the energy of ions that are not stopped in the NINA-2 instrument. Moreover, problems related to particles that cross the instrument in the opposite direction are addressed and shown to be a possible cause of particle misidentification. Measuring fluxes of low abundance elements like energetic helium ions requires a good characterisation of all possible sources of backgrounds in the detector. Hints to determine the several contributions to the background are presented herein and may be applied to extract an order of magnitude of energetic ions fluxes from existing data sets, while waiting for dedicated high performance instruments.

  6. Using XML and Java Technologies for Astronomical Instrument Control

    Science.gov (United States)

    Ames, Troy; Case, Lynne; Powers, Edward I. (Technical Monitor)

    2001-01-01

    Traditionally, instrument command and control systems have been highly specialized, consisting mostly of custom code that is difficult to develop, maintain, and extend. Such solutions are initially very costly and are inflexible to subsequent engineering change requests, increasing software maintenance costs. Instrument description is too tightly coupled with details of implementation. NASA Goddard Space Flight Center, under the Instrument Remote Control (IRC) project, is developing a general and highly extensible framework that applies to any kind of instrument that can be controlled by a computer. The software architecture combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML), a human readable and machine understandable way to describe structured data. A key aspect of the object-oriented architecture is that the software is driven by an instrument description, written using the Instrument Markup Language (IML), a dialect of XML. IML is used to describe the command sets and command formats of the instrument, communication mechanisms, format of the data coming from the instrument, and characteristics of the graphical user interface to control and monitor the instrument. The IRC framework allows the users to define a data analysis pipeline which converts data coming out of the instrument. The data can be used in visualizations in order for the user to assess the data in real-time, if necessary. The data analysis pipeline algorithms can be supplied by the user in a variety of forms or programming languages. Although the current integration effort is targeted for the High-resolution Airborne Wideband Camera (HAWC) and the Submillimeter and Far Infrared Experiment (SAFIRE), first-light instruments of the Stratospheric Observatory for Infrared Astronomy (SOFIA), the framework is designed to be generic and extensible so that it can be applied to any instrument. Plans are underway to test the framework

  7. Black carbon emissions in gasoline vehicle exhaust: a measurement and instrument comparison.

    Science.gov (United States)

    Kamboures, Michael A; Hu, Shishan; Yu, Yong; Sandoval, Julia; Rieger, Paul; Huang, Shiou-Mei; Zhang, Sherry; Dzhema, Inna; Huo, Darey; Ayala, Alberto; Chang, M C Oliver

    2013-08-01

    A pilot study was conducted to evaluate the performance and agreement of several commercially available black carbon (BC) measurement instruments, when applied to the quantification of BC in light-duty vehicle (LDV) exhaust. Samples from six vehicles, three fuels, and three driving cycles were used. The pilot study included determinations of the method detection limit (MDL) and repeatability. With respect to the MDL, the real-time instruments outperformed the time-integrated instruments, with MDL = 0.12 mg/mi for the AE51 Aethalometer, and 0.15 mg/mi for the Micro Soot Sensor (MSS), versus 0.38 mg/mi for the IMPROVE_A thermal/ optical method, and 0.35 mg/mi for the OT21_T Optical Transmissometer. The real-time instruments had repeatability values ranging from 30% to 35%, which are somewhat better than those of the time-integrated instruments (40-41%). These results suggest that, despite being less resource intensive, real-time methods can be equivalent or superior to time-integrated methods in terms of sensitivity and repeatability. BC mass data, from the photoacoustic and light attenuation instruments, were compared against same-test EC data, determined using the IMPROVE_A method. The MSS BC data was well correlated with EC, with R2 = 0.85 for the composite results and R2 = 0.86 for the phase-by-phase (PBP) results. The correlation of BC, by the AE51, AE22, and OT21_T with EC was moderate to weak. The weaker correlation was driven by the inclusion of US06 test data in the linear regression analysis. We hypothesize that test-cycle-dependent BC:EC ratios are due to the different physicochemical properties of particulate matter (PM) in US06 and Federal Test Procedure (FTP) tests. Correlation amongst the real-time MSS, PASS-1, AE51, and AE22 instruments was excellent (R2 = 0.83-0.95), below 1 mg/mi levels. In the process of investigating these BC instruments, we learned that BC emissions at sub-1 mg/mi levels can be measured and are achievable by current

  8. NBS SURF 11: A small versatile synchrotron light source

    International Nuclear Information System (INIS)

    Rakowsky, G.

    1981-01-01

    Synchrotron radiation sources do not have to be large multi-megadollar installations. SURF II is based on a compact electron storage ring with a radius of only 0.84 m, an operating energy of 250 MeV, and useful light output down to 5 nm. Small beam size, high brightness and wide-angle light ports give SURF II unique capabilities. Presently five beamlines are instrumented and operational, supporting experiments in atomic and molecular physics, surface science and materials studies, as well as providing optical calibration services. Nearing completion is a large facility for calibrating optical instruments, especially those intended for space flight. The capability of determining the absolute light flux emitted by SURF II has recently been improved and is now operational. The technique employs ultralinear silicon photodiodes to detect and count individual electrons in the stored beam. Other user conveniences include close access to the machine, flexible scheduling and close interaction with the operations staff. The machine's simplicity contributes to reliability and a high ratio of beamtime to downtime

  9. Diagnosis of canine echinococcosis: comparison of coproantigen detection with necropsy in stray dogs and red foxes from northern Jordan

    Directory of Open Access Journals (Sweden)

    El-Shehabi F.S.

    2000-06-01

    Full Text Available The sandwich enzyme linked immunosorbent assay (ELISA was used as a diagnostic test for Echinococcus granulosus infection by detecting coproantigens in 94 stray dogs Canis familiaris and eight red foxes (Vulpes vulpes from northern Jordan. The results were analyzed in relation to actual helminth infection as revealed by necropsy. The infection rate of dogs with E. granulosus was 13.8 % with a worm load ranging between 3 - > 10,000 per infected dog. In contrast, eight of 13 E. granulosus infected dogs were coproantigen positive (overall sensitivity 61.5 %. The sensitivity increased to 87.5 % and 100 % in dogs harboring > 20 and > 100 worms/dog, respectively. The specificity of coproantigen-ELISA was 91 %. The greatest cross-reactivity was found in dogs infected with Dipylidium caninum. The positive and negative predictive values for the coproantigen-ELISA test were 50 % and 94.2 %, respectively. Thus, a coproantigen negative dog is most probably truly negative for E. granulosus. In contrast, a coproantigen positive dog may not be truly positive for E. granulosus, except if it has a high worm burden of > 100 worms/animal.

  10. Time resolved super continuum Cavity Ring-Down Spectroscopy for multicomponent gas detection

    International Nuclear Information System (INIS)

    Nakaema, Walter Morinobu

    2010-01-01

    In this work, we present a variation of the technique CRDS (Cavity Ring-Down Spectroscopy) to obtain simultaneously a multicomponent absorption spectrum in a broad visible range. This new approach uses the Supercontinuum (SC) spectrum (resulting from irradiation of nonlinear media by femtosecond lasers, or simply generated by compact sources) as a light source to illuminate the cavity. In this context it is described the features of the modules assembling a MC-SC-CRDS (Multicomponent Supercontinuum Cavity Ring-Down Spectroscopy): a set of high reflectivity mirrors, the resonant cavity and the detection system. Some problems related to the multimode excitation, stray light, effective use of the dynamic range of the detector, the poor resolution of the instrument to resolve narrow absorption lines are issued. We present the absorption spectra of H 2 O (polyads 4υ, 4υ + δ) and O 2 (spin-forbidden b-X branch) measured simultaneously by this technique in the visible range and a comparison with the absorption lines based on HITRAN database is made to demonstrate the functionality of this method. (author)

  11. An echelle spectrograph for middle ultraviolet solar spectroscopy from rockets.

    Science.gov (United States)

    Tousey, R; Purcell, J D; Garrett, D L

    1967-03-01

    An echelle grating spectrograph is ideal for use in a rocket when high resolution is required becaus itoccupies a minimum of space. The instrument described covers the range 4000-2000 A with a resolution of 0.03 A. It was designed to fit into the solar biaxial pointing-control section of an Aerobee-150 rocket. The characteristics of the spectrograph are illustrated with laboratory spectra of iron and carbon are sources and with solar spectra obtained during rocket flights in 1961 and 1964. Problems encountered in analyzing the spectra are discussed. The most difficult design problem was the elimination of stray light when used with the sun. Of the several methods investigated, the most effective was a predispersing system in the form of a zero-dispersion double monochromator. This was made compact by folding the beam four times.

  12. Quasi-Elastic Light Scattering in Ophthalmology

    Science.gov (United States)

    Ansari, Rafat R.

    The eye is not just a "window to the soul"; it can also be a "window to the human body." The eye is built like a camera. Light which travels from the cornea to the retina traverses through tissues that are representative of nearly every tissue type and fluid type in the human body. Therefore, it is possible to diagnose ocular and systemic diseases through the eye. Quasi-elastic light scattering (QELS) also known as dynamic light scattering (DLS) is a laboratory technique routinely used in the characterization of macromolecular dispersions. QELS instrumentation has now become more compact, sensitive, flexible, and easy to use. These developments have made QELS/DLS an important tool in ophthalmic research where disease can be detected early and noninvasively before the clinical symptoms appear.

  13. The protection of personal data in the fight against terrorism
    New perspectives of PNR European Union instruments in the light of the Treaty of Lisbon

    Directory of Open Access Journals (Sweden)

    Michele Nino

    2010-01-01

    Full Text Available This article addresses the protection of personal data in the European Union in the context of the fight against international terrorism taking into account the new European Union architecture provided for by the Treaty of Lisbon. After having delineated the European legal background concerning the right to privacy, the author examines the Passenger Name Records (PNR Agreements concluded by the European Union with the United States, Canada and Australia. A further object of analysis is the 2007 proposal for a Council Framework Decision on the use of PNR data for law enforcement purposes, which is aimed at creating an autonomous PNR system in the European Union. The author considers that these instruments are likely to violate rights and fundamental freedoms of individuals, in particular the right to privacy. This is also due to the architecture of the European Union, whose structure is incapable of adequately and completely protecting the right to personal data protection. As a consequence, the author proposes solutions to modify PNR instruments, especially in light of the future changes that the Treaty of Lisbon will make to the structure of the European Union.

  14. The instrumental resolution of a moire extensometer in light of its recent automatisation

    Czech Academy of Sciences Publication Activity Database

    Rowberry, Matthew David; Kriegner, D.; Holý, V.; Frontera, C.; Llull, M.; Olejník, Kamil; Martí, Xavier

    2016-01-01

    Roč. 91, SEP (2016), s. 258-265 ISSN 0263-2241 R&D Projects: GA MŠk LM2010008 Institutional support: RVO:67985891 ; RVO:68378271 Keywords : geological discontinuity monitoring * mechanical extensometer * moire patterns * instrumental resolution Subject RIV: JB - Sensors, Measurment, Regulation; BM - Solid Matter Physics ; Magnetism (FZU-D) Impact factor: 2.359, year: 2016

  15. Instrumented module of the ATLAS tile calorimeter

    CERN Multimedia

    Laurent Guiraud

    1998-01-01

    The ATLAS tile calorimeter consists of steel absorber plates interspersed with plastic scintillator tiles. Interactions of high-energy hadrons in the plates transform the incident energy into a 'hadronic shower'. When shower particles traverse the scintillating tiles, the latter emit an amount of light proportional to the incident energy. This light is transmitted along readout fibres to a photomultiplier, where a detectable electrical signal is produced. These pictures show one of 64 modules or 'wedges' of the barrel part of the tile calorimeter, which are arranged to form a cylinder around the beam axis. The wedge has been instrumented with scintillators and readout fibres. Photos 03, 06: Checking the routing of the readout fibres into the girder that houses the photomultipliers. Photo 04: A view of the fibre bundles inside the girder.

  16. The digital reactor protection system for the instrumentation and control of reactor TRIGA PUSPATI (RTP)

    International Nuclear Information System (INIS)

    Nurfarhana Ayuni Joha; Izhar Abu Hussin; Mohd Idris Taib; Zareen Khan Abdul Jalil Khan

    2010-01-01

    Reactor Protection System (RPS) is important for Reactor Instrumentation and Control System. The RPS comprises all redundant electrical devices and circuitry involved in the generation of those initiating signals associated to the trip protective function. The instrumentation system for the RPS provides automatic protection signals against unsafe and improper reactor operation. The physical separation is provided for all of the redundant instrumentation systems to preserve redundancy. The safety protection systems using circuits composed of analog instruments and relays with relay contacts is difficult to realize from various reasons. Therefore, an application of digital technology can be said a logical conclusion also in the light of its functional superiority. (author)

  17. FIR laser scattering and heterodyne receiver measurements on Alcator C

    International Nuclear Information System (INIS)

    Woskoboinikow, P.; Praddaude, H.C.; Mulligan, W.J.; Cohn, D.R.; Lax, B.

    1982-01-01

    The MIT program to develop high power collective Thomson scattering diagnostics is presented. The D 2 O laser Thomson scattering system is operational on Alcator C tokamak. The major components include a 0.5 MW, 150 ns D 2 O laser, a heterodyne receiver mixer, a 25 MW, 381 μ DCOOD laser local oscillator and X-band I.F. electronics including a 32 channel multiplexer filter centered at 9.4 GHz with 80 MHz wide channels. Initial scattering measurement showed high level of stray D 2 O laser power. The spectrum was obtained by operating the Thomson scattering diagnostics with no plasma in the tokamak. An X-band notch filter was placed after the Schottky diode mixer to reject a 240 MHz band centered at 9.4 GHz. The stray light level was reduced by 16 to 20 db. Other sources of background noise such as strong non-thermal scattering and ECE did not appear to be a problem. A gas filled cell was placed on the Alcator C scattering system to reduce the level of stray light. Work is underway to improve the transverse mode quality of the laser and receiver to improve matching to the beam and viewing dumps. (Kato, T.)

  18. SOFIA science instruments: commissioning, upgrades and future opportunities

    Science.gov (United States)

    Smith, Erin C.; Miles, John W.; Helton, L. Andrew; Sankrit, Ravi; Andersson, B. G.; Becklin, Eric E.; De Buizer, James M.; Dowell, C. D.; Dunham, Edward W.; Güsten, Rolf; Harper, Doyal A.; Herter, Terry L.; Keller, Luke D.; Klein, Randolf; Krabbe, Alfred; Logsdon, Sarah; Marcum, Pamela M.; McLean, Ian S.; Reach, William T.; Richter, Matthew J.; Roellig, Thomas L.; Sandell, Göran; Savage, Maureen L.; Temi, Pasquale; Vacca, William D.; Vaillancourt, John E.; Van Cleve, Jeffrey E.; Young, Erick T.

    2014-07-01

    The Stratospheric Observatory for Infrared Astronomy (SOFIA) is the world's largest airborne observatory, featuring a 2.5 meter effective aperture telescope housed in the aft section of a Boeing 747SP aircraft. SOFIA's current instrument suite includes: FORCAST (Faint Object InfraRed CAmera for the SOFIA Telescope), a 5-40 μm dual band imager/grism spectrometer developed at Cornell University; HIPO (High-speed Imaging Photometer for Occultations), a 0.3-1.1μm imager built by Lowell Observatory; GREAT (German Receiver for Astronomy at Terahertz Frequencies), a multichannel heterodyne spectrometer from 60-240 μm, developed by a consortium led by the Max Planck Institute for Radio Astronomy; FLITECAM (First Light Infrared Test Experiment CAMera), a 1-5 μm wide-field imager/grism spectrometer developed at UCLA; FIFI-LS (Far-Infrared Field-Imaging Line Spectrometer), a 42-200 μm IFU grating spectrograph completed by University Stuttgart; and EXES (Echelon-Cross-Echelle Spectrograph), a 5-28 μm highresolution spectrometer designed at the University of Texas and being completed by UC Davis and NASA Ames Research Center. HAWC+ (High-resolution Airborne Wideband Camera) is a 50-240 μm imager that was originally developed at the University of Chicago as a first-generation instrument (HAWC), and is being upgraded at JPL to add polarimetry and new detectors developed at Goddard Space Flight Center (GSFC). SOFIA will continually update its instrument suite with new instrumentation, technology demonstration experiments and upgrades to the existing instrument suite. This paper details the current instrument capabilities and status, as well as the plans for future instrumentation.

  19. MICADO: first light imager for the E-ELT

    NARCIS (Netherlands)

    Davies, R.; Schubert, J.; Hartl, M.; Alves, J.; Clénet, Y.; Lang-Bardl, F.; Nicklas, H.; Pott, J. -U; Ragazzoni, R.; Tolstoy, E.; Agocs, T.; Anwand-Heerwart, H.; Barboza, S.; Baudoz, P.; Bender, R.; Bizenberger, P.; Boccaletti, A.; Boland, W.; Bonifacio, P.; Briegel, F.; Buey, T.; Chapron, F.; Cohen, M.; Czoske, O.; Dreizler, S.; Falomo, R.; Feautrier, P.; Förster Schreiber, N.; Gendron, E.; Genzel, R.; Glück, M.; Gratadour, D.; Greimel, R.; Grupp, F.; Häuser, M.; Haug, M.; Hennawi, J.; Hess, H. J.; Hörmann, V.; Hofferbert, R.; Hopp, U.; Hubert, Z.; Ives, D.; Kausch, W.; Kerber, F.; Kravcar, H.; Kuijken, K.; Leitzinger, M.; Leschinski, K.; Massari, D.; Mei, S.; Merlin, F.; Mohr, L.; Monna, A.; Müller, F.; Navarro, R.; Plattner, M.; Przybilla, N.; Ramlau, R.; Ramsay, S.; Ratzka, T.; Rhode, P.; Richter, J.; Rix, H. -W; Rodeghiero, G.; Rohloff, R. -R; Rousset, G.; Ruddenklau, R.; Schaffenroth, V.; Schlichter, J.; Sevin, A.; Stuik, R.; Sturm, E.; Thomas, J.; Tromp, N.; Turatto, M.; Verdoes-Kleijn, G.; Vidal, F.; Wagner, R.; Wegner, M.; Zeilinger, W.; Ziegler, B.; Zins, G.

    2016-01-01

    MICADO will equip the E-ELT with a first light capability for diffraction limited imaging at near-infrared wavelengths. The instrument's observing modes focus on various flavours of imaging, including astrometric, high contrast, and time resolved. There is also a single object spectroscopic mode

  20. Aerodynamics support of research instrument development

    Science.gov (United States)

    Miller, L. Scott

    1990-09-01

    A new velocimetry system is currently being developed at NASA LaRC. The device, known as a Doppler global velocimeter (DGV), can record three velocity components within a plane simultaneously and in near real time. To make measurements the DGV, like many other velocimetry systems, relies on the scattering of light from numerous small particles in a flow field. The particles or seeds are illuminated by a sheet of laser light and viewed by two CCD cameras. The scattered light from the particles will have a frequency which is a function of the source laser light frequency, the viewing angle, and most importantly the seed velocities. By determining the scattered light intensity the velocity can be measured at all points within the light sheet simultaneously. Upon completion of DGV component construction and initial check out a series of tests in the Basic Aerodynamic Research (wind) Tunnel (BART) are scheduled to verify instrument operation and accuracy. If the results are satisfactory, application of the DGV to flight measurements on the F-18 High Alpha Research Vehicle (HARV) are planned. The DGV verification test in the BART facility will utilize a 75 degree swept delta wing model. A major task undertaken this summer included evaluation of previous results for this model. A specific series of tests matching exactly the previous tests and exploring new DGV capabilities were developed and suggested. Another task undertaken was to study DGV system installation possibilities in the F-18 HARV aircraft. In addition, a simple seeding system modification was developed and utilized to make Particle Imaging Velocimetry (PIV) measurements in the BART facility.

  1. ISOMAX: a balloon-borne instrument to measure cosmic ray isotopes

    International Nuclear Information System (INIS)

    Hof, M.; Bremerich, M.; Goebel, H.; Hams, T.; Menn, W.; Simon, M.; Barbier, L.M.; Christian, E.R.; Geier, S.; Gupta, S.K.; Krizmanic, J.F.; Mitchell, J.W.; Ormes, J.F.; Streitmatter, R.E.; Davis, A.J.; Nolfo, G.A. de; Mewaldt, R.A.; Schindler, S.M.

    2000-01-01

    The Isotope Magnet Experiment (ISOMAX) is a new balloon-borne instrument developed to measure the isotopic composition of the light elements in the cosmic radiation, in particular to obtain the ratio of the radioactive 10 Be to stable 9 Be. ISOMAX was first flown in August 4-5, 1998, from Lynn Lake, Manitoba, Canada. ISOMAX has a geometry factor of 450 cm 2 sr and was configured for this flight with a large, Helmholtz-like, superconducting magnet in combination with a drift-chamber tracking system, a state-of-the-art time-of-flight system and two aerogel Cherenkov detectors to measure light isotopes with a mass resolution of better than 0.25 amu. In the 1998 flight the obtained maximum detectable rigidity of the magnetic spectrometer was 970 GeV/c for helium at 60% of the full magnetic field. ISOMAX took data for more than 16 h at float altitudes above 36 km. We here present the performance of the individual detectors and initial isotopic results of the instrument

  2. A leak-detection instrument for long buried pipelines based on radioactive tracer measurements

    International Nuclear Information System (INIS)

    Lu Qingqian; Zhou Shuxuan; Tang Yonghua; Sun Xiaolei; Hu Xusheng; Li Deyi; Yin Liqiang

    1987-01-01

    The instrument introduced provides a means for leak detection of long buried pipelines based on the radioactive tracer technique. The principle, block diagram and performances for the instrument are described. The leak-detecting method and the determination of some related parameters are also presented. Leak-detection sensitivity of the instrument is 185 kBq (5 μCi). Accuracy for leak localization is within 2.5 m (per km). It is suitable for the buried light oil (gasoline, kerosene, diesel oil) and industrial water pipelines with a diameter of 15 or 20 cm. The detection length for a single operation reaches up to 50 km

  3. Automated ultrasonic examination of light water reactor systems

    International Nuclear Information System (INIS)

    Walter, J.H.

    1975-01-01

    An automated ultrasonic examination system has been developed to meet the pre- and inservice inspection requirements of light water reactors. This system features remotely-controlled travelling instrument carriers, computerized collection and storage or inspection data in a manner providing real time comparison against code standards, and computer control over the positioning of the instrument carriers to provide precise location data. The system is currently being utilized in the field for a variety of reactor inspections. The principal features of the system and the recent inspection experience are discussed. (author)

  4. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. An inspector-instrument interface design that allows communication of procedures, responses, and results between the instrument and user is presented. This capability has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  5. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. This report describes an inspector-instrument interface design which allows communication of procedures, responses, and results between the instrument and user. The interface has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  6. Representation of chromatic distribution for lighting system

    Science.gov (United States)

    Rossi, Maurizio; Musante, Fulvio

    2015-01-01

    For the luminaire manufacturer, the measurement of the lighting intensity distribution (LID) emitted by lighting fixture is based on photometry. So light is measured as an achromatic value of intensity and there is no the possibility to discriminate the measurement of white vs. colored light. At the Laboratorio Luce of Politecnico di Milano a new instrument for the measurement of spectral radiant intensities distribution for lighting system has been built: the goniospectra- radiometer. This new measuring tool is based on a traditional mirror gonio-photometer with a CCD spectraradiometer controlled by a PC. Beside the traditional representation of photometric distribution we have introduced a new representation where, in addition to the information about the distribution of luminous intensity in space, new details about the chromaticity characteristic of the light sources have been implemented. Some of the results of this research have been applied in developing and testing a new line of lighting system "My White Light" (the research project "Light, Environment and Humans" funded in the Italian Lombardy region Metadistretti Design Research Program involving Politecnico di Milano, Artemide, Danese, and some other SME of the Lighting Design district), giving scientific notions and applicative in order to support the assumption that colored light sources can be used for the realization of interior luminaries that, other than just have low power consumption and long life, may positively affect the mood of people.

  7. Increased stray gas abundance in a subset of drinking water wells near Marcellus shale gas extraction.

    Science.gov (United States)

    Jackson, Robert B; Vengosh, Avner; Darrah, Thomas H; Warner, Nathaniel R; Down, Adrian; Poreda, Robert J; Osborn, Stephen G; Zhao, Kaiguang; Karr, Jonathan D

    2013-07-09

    Horizontal drilling and hydraulic fracturing are transforming energy production, but their potential environmental effects remain controversial. We analyzed 141 drinking water wells across the Appalachian Plateaus physiographic province of northeastern Pennsylvania, examining natural gas concentrations and isotopic signatures with proximity to shale gas wells. Methane was detected in 82% of drinking water samples, with average concentrations six times higher for homes gas wells (P = 0.0006). Ethane was 23 times higher in homes gas wells (P = 0.0013); propane was detected in 10 water wells, all within approximately 1 km distance (P = 0.01). Of three factors previously proposed to influence gas concentrations in shallow groundwater (distances to gas wells, valley bottoms, and the Appalachian Structural Front, a proxy for tectonic deformation), distance to gas wells was highly significant for methane concentrations (P = 0.007; multiple regression), whereas distances to valley bottoms and the Appalachian Structural Front were not significant (P = 0.27 and P = 0.11, respectively). Distance to gas wells was also the most significant factor for Pearson and Spearman correlation analyses (P gas wells was the only statistically significant factor (P gas (4)He to CH4 in groundwater were characteristic of a thermally postmature Marcellus-like source in some cases. Overall, our data suggest that some homeowners living gas wells have drinking water contaminated with stray gases.

  8. Energy Harvesting from the Stray Electromagnetic Field around the Electrical Power Cable for Smart Grid Applications.

    Science.gov (United States)

    Khan, Farid Ullah

    For wireless sensor node (WSN) applications, this paper presents the harvesting of energy from the stray electromagnetic field around an electrical power line. Inductive and capacitive types of electrodynamic energy harvesters are developed and reported. For the produced energy harvesters, solid core and split-core designs are adopted. The inductive energy harvester comprises a copper wound coil which is produced on a mild steel core. However, the capacitive prototypes comprise parallel, annular discs separated by Teflon spacers. Moreover, for the inductive energy harvesters' wound coil and core, the parametric analysis is also performed. A Teflon housing is incorporated to protect the energy harvester prototypes from the harsh environmental conditions. Among the inductive energy harvesters, prototype-5 has performed better than the other harvesters and produces a maximum rms voltage of 908 mV at the current level of 155 A in the power line. However, at the same current flow, the capacitive energy harvesters produce a maximum rms voltage of 180 mV. The alternating output of the prototype-5 is rectified, and a super capacitor (1 F, 5.5 V) and rechargeable battery (Nickel-Cadmium, 3.8 V) are charged with it. Moreover, with the utilization of a prototype-5, a self-powered wireless temperature sensing and monitoring system for an electrical transformer is also developed and successfully implemented.

  9. Determination of the Performance Parameters of a Spectrophotometer: An Advanced Experiment.

    Science.gov (United States)

    Cope, Virgil W.

    1978-01-01

    Describes an advanced analytical chemistry laboratory experiment developed for the determination of the performance parameters of a spectrophotometer. Among the parameters are the baseline linearity with wavelength, wavelength accuracy and respectability, stray light, noise level and pen response time. (HM)

  10. Current schemes for National Synchrotron Light Source UV beamlines

    International Nuclear Information System (INIS)

    Williams, G.P.; Howells, M.R.; McKinney, W.R.

    1979-01-01

    We describe in some detail four beamlines proposed for the National Synchrotron Light Source uv ring at Brookhaven National Laboratory. Three grazing-incidence instruments, one of the plane grating Mijake type and two with toroidal gratings at grazing angles of 2-1/2 0 and 15 0 are described. Two normal incidence instruments, one using the source as entrance slit and accepting 75 milliradians horizontally are also discussed. In each case we have estimated the output fluxes expected from such beamlines

  11. The new versatile general purpose surface-muon instrument (GPS) based on silicon photomultipliers for μSR measurements on a continuous-wave beam.

    Science.gov (United States)

    Amato, A; Luetkens, H; Sedlak, K; Stoykov, A; Scheuermann, R; Elender, M; Raselli, A; Graf, D

    2017-09-01

    We report on the design and commissioning of a new spectrometer for muon-spin relaxation/rotation studies installed at the Swiss Muon Source (SμS) of the Paul Scherrer Institute (PSI, Switzerland). This new instrument is essentially a new design and replaces the old general-purpose surface-muon (GPS) instrument that has been for long the workhorse of the μSR user facility at PSI. By making use of muon and positron detectors made of plastic scintillators read out by silicon photomultipliers, a time resolution of the complete instrument of about 160 ps (standard deviation) could be achieved. In addition, the absence of light guides, which are needed in traditionally built μSR instrument to deliver the scintillation light to photomultiplier tubes located outside magnetic fields applied, allowed us to design a compact instrument with a detector set covering an increased solid angle compared with the old GPS.

  12. Instrumentation in high energy physics

    International Nuclear Information System (INIS)

    Serin, L.

    2007-01-01

    The instrumentation in high energy physics is a wide and advanced domain which cannot be covered in a single lesson. The main basic physics processes for charged and neutral particles are recalled with the definition of a few concepts needed to understand or design a detector. The application of these principles to charged particle measurement devices (momentum), light detection or energy measurement are presented mostly with examples from collider experiments. The particle identification which is often the combination of different techniques in a same experiment is also discussed. Finally in a very short section, a few considerations about electronics/processing with their impact on the detector performance are given

  13. Invited Article: Deep Impact instrument calibration.

    Science.gov (United States)

    Klaasen, Kenneth P; A'Hearn, Michael F; Baca, Michael; Delamere, Alan; Desnoyer, Mark; Farnham, Tony; Groussin, Olivier; Hampton, Donald; Ipatov, Sergei; Li, Jianyang; Lisse, Carey; Mastrodemos, Nickolaos; McLaughlin, Stephanie; Sunshine, Jessica; Thomas, Peter; Wellnitz, Dennis

    2008-09-01

    Calibration of NASA's Deep Impact spacecraft instruments allows reliable scientific interpretation of the images and spectra returned from comet Tempel 1. Calibrations of the four onboard remote sensing imaging instruments have been performed in the areas of geometric calibration, spatial resolution, spectral resolution, and radiometric response. Error sources such as noise (random, coherent, encoding, data compression), detector readout artifacts, scattered light, and radiation interactions have been quantified. The point spread functions (PSFs) of the medium resolution instrument and its twin impactor targeting sensor are near the theoretical minimum [ approximately 1.7 pixels full width at half maximum (FWHM)]. However, the high resolution instrument camera was found to be out of focus with a PSF FWHM of approximately 9 pixels. The charge coupled device (CCD) read noise is approximately 1 DN. Electrical cross-talk between the CCD detector quadrants is correctable to <2 DN. The IR spectrometer response nonlinearity is correctable to approximately 1%. Spectrometer read noise is approximately 2 DN. The variation in zero-exposure signal level with time and spectrometer temperature is not fully characterized; currently corrections are good to approximately 10 DN at best. Wavelength mapping onto the detector is known within 1 pixel; spectral lines have a FWHM of approximately 2 pixels. About 1% of the IR detector pixels behave badly and remain uncalibrated. The spectrometer exhibits a faint ghost image from reflection off a beamsplitter. Instrument absolute radiometric calibration accuracies were determined generally to <10% using star imaging. Flat-field calibration reduces pixel-to-pixel response differences to approximately 0.5% for the cameras and <2% for the spectrometer. A standard calibration image processing pipeline is used to produce archival image files for analysis by researchers.

  14. Invited Article: Deep Impact instrument calibration

    International Nuclear Information System (INIS)

    Klaasen, Kenneth P.; Mastrodemos, Nickolaos; A'Hearn, Michael F.; Farnham, Tony; Groussin, Olivier; Ipatov, Sergei; Li Jianyang; McLaughlin, Stephanie; Sunshine, Jessica; Wellnitz, Dennis; Baca, Michael; Delamere, Alan; Desnoyer, Mark; Thomas, Peter; Hampton, Donald; Lisse, Carey

    2008-01-01

    Calibration of NASA's Deep Impact spacecraft instruments allows reliable scientific interpretation of the images and spectra returned from comet Tempel 1. Calibrations of the four onboard remote sensing imaging instruments have been performed in the areas of geometric calibration, spatial resolution, spectral resolution, and radiometric response. Error sources such as noise (random, coherent, encoding, data compression), detector readout artifacts, scattered light, and radiation interactions have been quantified. The point spread functions (PSFs) of the medium resolution instrument and its twin impactor targeting sensor are near the theoretical minimum [∼1.7 pixels full width at half maximum (FWHM)]. However, the high resolution instrument camera was found to be out of focus with a PSF FWHM of ∼9 pixels. The charge coupled device (CCD) read noise is ∼1 DN. Electrical cross-talk between the CCD detector quadrants is correctable to <2 DN. The IR spectrometer response nonlinearity is correctable to ∼1%. Spectrometer read noise is ∼2 DN. The variation in zero-exposure signal level with time and spectrometer temperature is not fully characterized; currently corrections are good to ∼10 DN at best. Wavelength mapping onto the detector is known within 1 pixel; spectral lines have a FWHM of ∼2 pixels. About 1% of the IR detector pixels behave badly and remain uncalibrated. The spectrometer exhibits a faint ghost image from reflection off a beamsplitter. Instrument absolute radiometric calibration accuracies were determined generally to <10% using star imaging. Flat-field calibration reduces pixel-to-pixel response differences to ∼0.5% for the cameras and <2% for the spectrometer. A standard calibration image processing pipeline is used to produce archival image files for analysis by researchers.

  15. Deep-learnt classification of light curves

    DEFF Research Database (Denmark)

    Mahabal, Ashish; Gieseke, Fabian; Pai, Akshay Sadananda Uppinakudru

    2017-01-01

    is to derive statistical features from the time series and to use machine learning methods, generally supervised, to separate objects into a few of the standard classes. In this work, we transform the time series to two-dimensional light curve representations in order to classify them using modern deep......Astronomy light curves are sparse, gappy, and heteroscedastic. As a result standard time series methods regularly used for financial and similar datasets are of little help and astronomers are usually left to their own instruments and techniques to classify light curves. A common approach...... learning techniques. In particular, we show that convolutional neural networks based classifiers work well for broad characterization and classification. We use labeled datasets of periodic variables from CRTS survey and show how this opens doors for a quick classification of diverse classes with several...

  16. Effects of Color Light and Relaxation Exercise Therapy on Adults with Learning Disabilities.

    Science.gov (United States)

    Rustigan, Carol J.

    In a study at California State University, Sacramento, the effects of color light and relaxation exercise therapy were investigated with 16 students (ages 23 to 48) with learning disabilities. Therapy consisted of either 20 sessions viewing color light through a Lumatron instrument or 20 sessions listening to relaxation exercise tapes. Diagnostic…

  17. VizieR Online Data Catalog: Praesepe members light curves (Kovacs+, 2014)

    Science.gov (United States)

    Kovacs, G.; Hartman, J. D.; Bakos, G. A.; Quinn, S. N.; Penev, K.; Latham, D. W.; Bhatti, W.; Csubry, Z.; de Val-Borro, M.

    2014-07-01

    Light curves used in the time series analysis of Praesepe are presented. There are 381 light curves on instrumental Sloan r' magnitude scale with the zero points determined by the 2MASS magnitudes according to Eq. (1) of the paper. We present two types of magnitudes: a) external parameter decorrelated (EPD) and b), the ones obtained after the application of a trend filtering algorithm (TFA) on the EPD time series. These two methods are briefly described in the paper and in detail in the references therein. Here we just note that both methods are intended to filter out systematics due to environmental effects (instrumental, weather, etc.). For TFA filtering we used 600 templates and did not apply signal reconstruction. (5 data files).

  18. 77 FR 74647 - Application(s) for Duty-Free Entry of Scientific Instruments

    Science.gov (United States)

    2012-12-17

    ... University, 525 Northwestern Ave., West Lafayette, IN 47907-2036. Instrument: DD Neutron Generator... scintillation light and ionization behavior of liquid xenon to neutrons from a mono- energetic neutron source with energies close to 2.5 MeV, each neutron interaction must be resolved separately, and thus arrive...

  19. A triple spectrograph system for low stray light Thomson scattering measurements

    NARCIS (Netherlands)

    Sande, van de M.J.; Mullen, van der J.J.A.M.

    2001-01-01

    Thomson scattering is scattering of photons by the electrons in a plasma. From the scattering spectrum, the electron temperature and density (Te, ne) of the plasma can be deduced. In the past decade, the development of high power lasers and sensitive detection devices has made Thomson scattering a

  20. VIBRATIONAL SPECTRA OF t-BUTYL ALCOHOL, t-BUTYLAMINE ...

    African Journals Online (AJOL)

    a

    good stray light rejection. A Spectra-Physics ... the spectrometer. The vial was then spun to enhance the Raman signal and reduce the risk of .... *Abbreviations used: m, medium; s, strong; v, very; w, weak; sh, shoulder; -, not detected due to the ...

  1. Bringing the light to high throughput screening: use of optogenetic tools for the development of recombinant cellular assays

    Science.gov (United States)

    Agus, Viviana; Di Silvio, Alberto; Rolland, Jean Francois; Mondini, Anna; Tremolada, Sara; Montag, Katharina; Scarabottolo, Lia; Redaelli, Loredana; Lohmer, Stefan

    2015-03-01

    The use of light-activated proteins represents a powerful tool to control biological processes with high spatial and temporal precision. These so called "optogenetic" technologies have been successfully validated in many recombinant systems, and have been widely applied to the study of cellular mechanisms in intact tissues or behaving animals; to do that, complex, high-intensity, often home-made instrumentations were developed to achieve the optimal power and precision of light stimulation. In our study we sought to determine if this optical modulation can be obtained also in a miniaturized format, such as a 384-well plate, using the instrumentations normally dedicated to fluorescence analysis in High Throughput Screening (HTS) activities, such as for example the FLIPR (Fluorometric Imaging Plate Reader) instrument. We successfully generated optogenetic assays for the study of different ion channel targets: the CaV1.3 calcium channel was modulated by the light-activated Channelrhodopsin-2, the HCN2 cyclic nucleotide gated (CNG) channel was modulated by the light activated bPAC adenylyl cyclase, and finally the genetically encoded voltage indicator ArcLight was efficiently used to measure potassium, sodium or chloride channel activity. Our results showed that stable, robust and miniaturized cellular assays can be developed using different optogenetic tools, and efficiently modulated by the FLIPR instrument LEDs in a 384-well format. The spatial and temporal resolution delivered by this technology might enormously advantage the early stages of drug discovery, leading to the identification of more physiological and effective drug molecules.

  2. Induced Radioactivity in Lead Shielding at the National Synchrotron Light Source.

    Science.gov (United States)

    Ghosh, Vinita J; Schaefer, Charles; Kahnhauser, Henry

    2017-06-01

    The National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory was shut down in September 2014. Lead bricks used as radiological shadow shielding within the accelerator were exposed to stray radiation fields during normal operations. The FLUKA code, a fully integrated Monte Carlo simulation package for the interaction and transport of particles and nuclei in matter, was used to estimate induced radioactivity in this shielding and stainless steel beam pipe from known beam losses. The FLUKA output was processed using MICROSHIELD® to estimate on-contact exposure rates with individually exposed bricks to help design and optimize the radiological survey process. This entire process can be modeled using FLUKA, but use of MICROSHIELD® as a secondary method was chosen because of the project's resource constraints. Due to the compressed schedule and lack of shielding configuration data, simple FLUKA models were developed. FLUKA activity estimates for stainless steel were compared with sampling data to validate results, which show that simple FLUKA models and irradiation geometries can be used to predict radioactivity inventories accurately in exposed materials. During decommissioning 0.1% of the lead bricks were found to have measurable levels of induced radioactivity. Post-processing with MICROSHIELD® provides an acceptable secondary method of estimating residual exposure rates.

  3. Experimental light scattering by small particles in Amsterdam and Granada

    Directory of Open Access Journals (Sweden)

    Volten H.

    2010-06-01

    Full Text Available We report on two light scattering instruments located in Amsterdam and Granada, respectively. These instruments enable measuring scattering matrices as functions of the scattering angle of collections of randomly orieneted irregular particles. In the past decades, the experimental setup located in Amsterdam, The Netherlands, has produced a significant amount of experimental data. Unfortunately, this setup was officially closed a couple of years ago. We also present a modernized descendant of the Dutch experimental setup recently constructed at the Instituto de Astrofísica de Andalucía (IAA in Granada, Spain. We give a brief description of the instruments, and present some representative results.

  4. Geographic distribution of canine heartworm (Dirofilaria immitis infection in stray dogs of eastern Romania

    Directory of Open Access Journals (Sweden)

    Lavinia Ciucă

    2016-11-01

    Full Text Available A survey was conducted in the eastern part of Romania to assess the prevalence and geographical distribution of Dirofilaria immitis in dogs. Plasma samples were collected from 458 stray dogs hosted in shelters in 8 counties and tested serologically for the presence of heartworm. In addition, 45 blood samples from dogs of a shelter in Galati city were examined by the modified Knott and multiplex polymerase chain reaction (PCR techniques. The immmunological assay showed a heartworm infection prevalence of 8.9% in the dogs. Optical density results for positive samples ranged between 0.217 and 2.683. Geographical information systems (GIS were used to produce overlays of distribution maps of D. immitis prevalence and predictive maps based on temperature suitability. High prevalence of D. immitis was found in the central East up to the northern border of the country, i.e. Galati county (60%, followed by the counties of Vaslui (12.0% and Iasi (7.7%. Out of 45 samples examined using the Knott test, 23 were positive for circulating microfilariae (51.1%, while 19 dogs were positive for D. immitis and 4 for both D. immitis and D. repens with the multiplex PCR test. The high prevalence for D. immitis shown in dogs in the Southeast (Galati, 42.2% also by multiplex PCR gave strong support to the results achieved by the serological tests. The present study confirms the ability of GIS to predict the distribution and epidemiology of dirofilariosis in different geographical territories as has been already demonstrated by the empirical epidemiological data obtained at the continental, national and intraregional levels.

  5. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  6. AsteroidFinder - the space-borne telescope to search for NEO Asteroids

    Science.gov (United States)

    Hartl, M.; Mosebach, H.; Schubert, J.; Michaelis, H.; Mottola, S.; Kührt, E.; Schindler, K.

    2017-11-01

    This paper presents the mission profile as well as the optical configuration of the space-borne AsteroidFinder telescope. Its main objective is to retrieve asteroids with orbits interior to the earth's orbit. The instrument requires high sensitivity to detect asteroids with a limiting magnitude of equal or larger than 18.5mag (V-Band) and astrometric accuracy of 1arcsec (1σ). This requires a telescope aperture greater than 400cm2, high image stability, detector with high quantum efficiency (peak > 90%) and very low noise, which is only limited by zodiacal background. The telescope will observe the sky between 30° and 60° in solar elongation. The telescope optics is based on a Cook type TMA. An effective 2°×2° field of view (FOV) is achieved by a fast F/3.4 telescope with near diffraction-limited performance. The absence of centre obscuration or spiders in combination with an accessible intermediate field plane and exit pupil allow for efficient stray light mitigation. Design drivers for the telescope are the required point spread function (PSF) values, an extremely efficient stray light suppression (due to the magnitude requirement mentioned above), the detector performance, and the overall optical and mechanical stability for all orientations of the satellite. To accommodate the passive thermal stabilization scheme and the necessary structural stability, the materials selection for the telescope main structure and the mirrors are of vital importance. A focal plane with four EMCCD detectors is envisaged. The EMCCD technology features shorter integration times, which is in favor regarding the pointing performance of the satellite. The launch of the mission is foreseen for the year 2013 with a subsequent mission lifetime of at least 1 year.

  7. Broad bandwidth frequency domain instrument for quantitative tissue optical spectroscopy

    International Nuclear Information System (INIS)

    Pham, Tuan H.; Coquoz, Olivier; Fishkin, Joshua B.; Anderson, Eric; Tromberg, Bruce J.

    2000-01-01

    Near-infrared (NIR) optical properties of turbid media, e.g., tissue, can be accurately quantified noninvasively using methods based on diffuse reflectance or transmittance, such as frequency domain photon migration (FDPM). Factors which govern the accuracy and sensitivity of FDPM-measured optical properties include instrument performance, the light propagation model, and fitting algorithms used to calculate optical properties from measured data. In this article, we characterize instrument, model, and fitting uncertaintics of an FDPM system designed for clinical use and investigate how each of these factors affects the quantification of NIR absorption (μ a ) and reduced scattering (μ s ' ) parameters in tissue phantoms. The instrument is based on a 500 MHz, multiwavelength platform that sweeps through 201 discrete frequencies in as little as 675 ms. Phase and amplitude of intensity modulated light launched into tissue, i.e., diffuse photon density waves (PDW), are measured with an accuracy of ±0.30 degree sign and ±3.5%, while phase and amplitude precision are ±0.025 degree sign and ±0.20%, respectively. At this level of instrument uncertainty, simultaneous fitting of frequency-dependent phase and amplitude nonlinear model functions derived from a photon diffusion approximation provides an accurate and robust strategy for determining optical properties from FDPM data, especially for media with high absorption. In an optical property range that is characteristic of most human tissues in the NIR (5x10 -3 a -2 mm -1 , 0.5 s ' -1 ), we theoretically and experimentally demonstrate that the multifrequency, simultaneous-fit approach allows μ a and μ s ' to be quantified with an accuracy of ±5% and ±3%, respectively. Although exceptionally high levels of precision can be obtained using this approach ( a and μ s ' . (c) 2000 American Institute of Physics

  8. Effect of Housing Rats in Dim Light or Long Nights on Heart Rate

    OpenAIRE

    Azar, Toni A; Sharp, Jody L; Lawson, David M

    2008-01-01

    Housing laboratory animals under lighting conditions that more closely mimic the natural environment may improve their wellbeing. This study examined the effects of dim light or a long-night photocycle on resting heart rate (HR) of rats and their HR responses to acute procedures. Male and female Sprague–Dawley (SD) and spontaneously hypertensive (SHR) rats, instrumented with radiotelemetry transmitters and housed individually under a 12:12-h light:dark photocycle with 10 lx illumination (dim ...

  9. Development an Instrument to Measure University Students' Attitude towards E-Learning

    Science.gov (United States)

    Mehra, Vandana; Omidian, Faranak

    2012-01-01

    The study of student's attitude towards e-learning can in many ways help managers better prepare in light of e-learning for the future. This article describes the process of the development of an instrument to measure university students' attitude towards e-learning. The scale was administered to 200 University students from two countries (India…

  10. Build Your Own Photometer: A Guided-Inquiry Experiment to Introduce Analytical Instrumentation

    Science.gov (United States)

    Wang, Jessie J.; Nun´ez, Jose´ R. Rodríguez; Maxwell, E. Jane; Algar, W. Russ

    2016-01-01

    A guided-inquiry project designed to teach students the basics of spectrophotometric instrumentation at the second year level is presented. Students design, build, program, and test their own single-wavelength, submersible photometer using low-cost light-emitting diodes (LEDs) and inexpensive household items. A series of structured prelaboratory…

  11. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  12. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  13. Understanding the proton radius puzzle: Nuclear structure effects in light muonic atoms

    Directory of Open Access Journals (Sweden)

    Ji Chen

    2016-01-01

    Full Text Available We present calculations of nuclear structure effects to the Lamb shift in light muonic atoms. We adopt a modern ab-initio approach by combining state-of-the-art nuclear potentials with the hyperspherical harmonics method. Our calculations are instrumental to the determination of nuclear charge radii in the Lamb shift measurements, which will shed light on the proton radius puzzle.

  14. All-silicon Michelson instrument on chip: Distance and surface profile measurement and prospects for visible light spectrometry

    International Nuclear Information System (INIS)

    Malak, M.; Marty, F.; Bourouina, T.; Nouira, H.; Vailleau, G.

    2013-01-01

    A miniature Michelson interferometer is analyzed theoretically and experimentally. The fabricated micro-interferometer is incorporated at the tip of a monolithic silicon probe to achieve contactless distance measurements and surface profilometry. For infrared operation, two approaches are studied, based on the use of monochromatic light and wavelength sweep, respectively. A theoretical model is devised to depict the system characteristics taking into account Gaussian beam divergence and light spot size. Furthermore, preliminary results using visible light demonstrate operation of the probe as a visible light spectrometer, despite silicon absorbance, thanks to the micrometer thickness involved in the beam splitter.

  15. All-silicon Michelson instrument on chip: Distance and surface profile measurement and prospects for visible light spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Malak, M.; Marty, F.; Bourouina, T. [Universite Paris-Est, Laboratoire ESYCOM, ESIEE Paris, Cite Descartes, 2 Boulevard Blaise Pascal, 93162 Noisy-le-Grand Cedex (France); Nouira, H.; Vailleau, G. [Laboratoire National de Metrologie et d' Essais, 1 rue Gaston Boissier, 75724 Paris Cedex 15 (France)

    2013-04-08

    A miniature Michelson interferometer is analyzed theoretically and experimentally. The fabricated micro-interferometer is incorporated at the tip of a monolithic silicon probe to achieve contactless distance measurements and surface profilometry. For infrared operation, two approaches are studied, based on the use of monochromatic light and wavelength sweep, respectively. A theoretical model is devised to depict the system characteristics taking into account Gaussian beam divergence and light spot size. Furthermore, preliminary results using visible light demonstrate operation of the probe as a visible light spectrometer, despite silicon absorbance, thanks to the micrometer thickness involved in the beam splitter.

  16. Prevalence of gastrointestinal parasites of stray dogs impounded by the Society for the Prevention of Cruelty to Animals (SPCA), Durban and Coast, South Africa.

    Science.gov (United States)

    Mukaratirwa, S; Singh, V P

    2010-06-01

    Coprological examination was used to determine the prevalence and intensity of gastrointestinal parasites of stray dogs impounded by the Society for the Prevention of Cruelty to Animals (SPCA), Durban and Coast, South Africa. Helminth and protozoan parasites were found in faeces of 240 dogs with an overall prevalence of 82.5% (helminth parasites 93.1% and protozoan parasites 6.9%). The following parasites and their prevalences were detected; Ancylostoma sp. (53.8%), Trichuris vulpis (7.9%), Spirocerca lupi (5.4%), Toxocara canis (7.9%), Toxascaris leonina (0.4%) Giardia intestinalis (5.6%) and Isospora sp. (1.3%). Dogs harbouring a single parasite species were more common (41.7%) than those harbouring 2 (15%) or multiple (2.1%) species. Ancylostoma sp., Toxocara canis and Giardia intestinalis have zoonotic potential and were detected in 66.7% of the samples.

  17. Evaluation of surface preparation and maintenance of canal curvature following instrumentation with hand ′K′ file and three different Ni-Ti rotary systems: A radiographic and SEM study

    Directory of Open Access Journals (Sweden)

    Namrata Bhatti

    2010-01-01

    Full Text Available Aim: To determine the shaping ability and cleaning efficiency of hand K-flexofiles, ProTaper, LightSpeed and Mtwo instruments during the preparation of curved root canals in extracted human teeth. Materials and Methods: A total of 120 root canals of mandibular and maxillary molars with curvature more than 20° were divided into four groups of 30 each. In group A, canals were prepared using hand K-flexofiles following the crown down technique. In group B LightSpeed, in group C ProTaper, and in group D Mtwo rotary instruments were used to prepare the root canals. Using pre- and post-instrumentation radiographs, straightening of the canal curvature was determined with Corel Draw 9.0 software tools. The amount of debris and smear layer were quantified at three different areas (coronal, middle, and apical thirds of root canal using SEM. The collected data were analyzed statistically using Student′s paired ′t′ test. Results: The mean change in curvature for hand K-files was 7.71°, for ProTaper files 6.03°, for Mtwo 5.43°, and for LightSpeed instruments were found to be 4.57°. The percentage change in the curvature for all the four groups was statistically highly significant (P< 0.01. LightSpeed instruments maintained the original canal curvature significantly (P< 0.01 better than the other instruments. For leftover debris, the minimum percentage was found to be associated with ProTaper (65.48% followed by Mtwo (66.22%, LightSpeed (71.67% and the maximum with hand K-files (74.16%. However, the difference in mean leftover debris between ProTaper and Mtwo was not significant. Conclusion: ProTaper and Mtwo resulted in good cleaning, and LightSpeed maintained the original canal curvature better than the ProTaper, Mtwo, or Hand K-files.

  18. Optical instrumentation for science and formation flying with a starshade observatory

    Science.gov (United States)

    Martin, Stefan; Scharf, Daniel; Cady, Eric; Liebe, Carl; Tang, Hong

    2015-09-01

    In conjunction with a space telescope of modest size, a starshade enables observation of small exoplanets close to the parent star by blocking the direct starlight while the planet light remains unobscured. The starshade is flown some tens of thousands of kilometers ahead of the telescope. Science instruments may include a wide field camera for imaging the target exoplanetary system as well as an integral field spectrometer for characterization of exoplanet atmospheres. We show the preliminary designs of the optical instruments for observatories such as Exo-S, discuss formation flying and control, retargeting maneuvers and other aspects of a starshade mission. The implementation of a starshade-ready WFIRST-AFTA is discussed and we show how a compact, standalone instrument package could be developed as an add-on to future space telescopes, requiring only minor additions to the telescope spacecraft.

  19. Black molecular adsorber coatings for spaceflight applications

    Science.gov (United States)

    Abraham, Nithin S.; Hasegawa, Mark M.; Straka, Sharon A.

    2014-09-01

    The molecular adsorber coating is a new technology that was developed to mitigate the risk of on-orbit molecular contamination on spaceflight missions. The application of this coating would be ideal near highly sensitive, interior surfaces and instruments that are negatively impacted by outgassed molecules from materials, such as plastics, adhesives, lubricants, epoxies, and other similar compounds. This current, sprayable paint technology is comprised of inorganic white materials made from highly porous zeolite. In addition to good adhesion performance, thermal stability, and adsorptive capability, the molecular adsorber coating offers favorable thermal control characteristics. However, low reflectivity properties, which are typically offered by black thermal control coatings, are desired for some spaceflight applications. For example, black coatings are used on interior surfaces, in particular, on instrument baffles for optical stray light control. Similarly, they are also used within light paths between optical systems, such as telescopes, to absorb light. Recent efforts have been made to transform the white molecular adsorber coating into a black coating with similar adsorptive properties. This result is achieved by optimizing the current formulation with black pigments, while still maintaining its adsorption capability for outgassing control. Different binder to pigment ratios, coating thicknesses, and spray application techniques were explored to develop a black version of the molecular adsorber coating. During the development process, coating performance and adsorption characteristics were studied. The preliminary work performed on black molecular adsorber coatings thus far is very promising. Continued development and testing is necessary for its use on future contamination sensitive spaceflight missions.

  20. Ectoparasites in urban stray cats in Jerusalem, Israel: differences in infestation patterns of fleas, ticks and permanent ectoparasites.

    Science.gov (United States)

    Salant, H; Mumcuoglu, K Y; Baneth, G

    2014-09-01

    In a period cross-sectional study performed to examine ectoparasites on 340 stray cats in Jerusalem, Israel, 186 (54.7%) were infested with the cat flea, Ctenocephalides felis (Siphonaptera: Pulicidae), 49 (14.4%) with the cat louse, Felicola subrostratus (Phthiraptera: Trichodectidae), 41 (12.0%) with the ear mite, Otodectes cynotis (Astigmata: Psoroptidae), three (0.9%) with the fur mite, Cheyletiella blakei (Trobidiformes: Cheyletidae), two (0.6%) with the itch mite Notoedres cati (Astigmata: Sarcoptidae), and 25 (7.3%) with ticks of the species Rhipicephalus sanguineus sensu lato (Ixodida: Ixodidae), Rhipicephalus turanicus or Haemaphysalis adleri (Ixodida: Ixodidae). A higher number of flea infestations was observed in apparently sick cats (P < 0.05) and in cats aged < 6 months (P < 0.05). The proportion of flea-infested cats (P < 0.01), as well as the number of fleas per infested cat (P < 0.01), was higher in autumn than in other seasons. By contrast with findings in cats with flea infestations, rates of infestation with ticks were higher amongst cats with clinical signs (P < 0.01) and cats aged ≥ 6 months (P < 0.05). The high rates of ectoparasite infestation in the cats studied constitute a risk for the spread of vector-borne infections of zoonotic and veterinary importance. © 2013 The Royal Entomological Society.

  1. Thomson scattering on non-equilibrium low density plasmas : principles, practice and challenges

    NARCIS (Netherlands)

    Carbone, E.A.D.; Nijdam, S.

    2015-01-01

    In this paper, we review the main challenges related to laser Thomson scattering on low temperature plasmas. The main features of the triple grating spectrometer used to discriminate Thomson and Raman scattering signals from Rayleigh scattering and stray light are presented. The main parameters

  2. Upgrade of the automatic analysis system in the TJ-II Thomson Scattering diagnostic: New image recognition classifier and fault condition detection

    NARCIS (Netherlands)

    Makili, L.; Vega, J.; Dormido-Canto, S.; Pastor, I.; Pereira, A.; Farias, G.; Portas, A.; Perez-Risco, D.; Rodriguez-Fernandez, M. C.; Busch, P.

    2010-01-01

    An automatic image classification system based on support vector machines (SVM) has been in operation for years in the TJ-II Thomson Scattering diagnostic. It recognizes five different types of images: CCD camera background, measurement of stray light without plasma or in a collapsed discharge,

  3. Coupled thermo-elastic and optical performance analyses of a reflective baffle for the BepiColombo laser altimeter (BELA) receiver

    Science.gov (United States)

    Heesel, E.; Weigel, T.; Lochmatter, P.; Rugi Grond, E.

    2017-11-01

    For the BepiColombo mission, the extreme thermal environment around Mercury requires good heat shields for the instruments. The BepiColombo Laser altimeter (BELA) Receiver will be equipped with a specular reflective baffle in order to limit the solar power impact. The design uses a Stavroudis geometry with alternating elliptical and hyperbolic vanes to reflect radiation at angles >38° back into space. The thermal loads on the baffle lead to deformations, and the resulting changes in the optical performance can be modeled by ray-tracing. Conventional interfaces, such as Zernike surface fitting, fail to provide a proper import of the mechanical distortions into optical models. We have studied alternative models such as free form surface representations and compared them to a simple modeling approach with straight segments. The performance merit is presented in terms of the power rejection ratio and the absence of specular stray-light.

  4. A new design of neutron survey instrument

    International Nuclear Information System (INIS)

    Tanner, R.J.; Eakins, J.S.; Hager, L.G.

    2010-01-01

    A novel design of neutron survey instrument has been developed. The moderator has been modified via the use of 'neutron guides', which help thermal neutrons reach the central proportional counter. This innovation has allowed the variations in the energy dependence of ambient dose equivalent response to be reduced compared to prior single-detector designs, whilst maintaining a relatively light moderator and simple construction. In particular, the design has a relatively small over-response to neutrons with energies around 5 keV, when compared to prior designs. The final optimized design has been verified using MCNP5 calculations to ensure that the response is relatively independent of the energy and direction of the incident neutron. This has required the ends of the guides to be structured so that unidirectional and isotropic neutron fields have closely matched responses, as is necessary in the workplace. The reading of the instrument in workplace fields is calculated via folding and the suitability of the design for use in the workplace discussed.

  5. Hexabundles: imaging fibre arrays for low-light astronomical applications

    DEFF Research Database (Denmark)

    Bland-Hawthorn, Joss; Bryant, Julie; Robertson, Gordon

    2010-01-01

    We demonstrate for the first time an imaging fibre bundle (“hexabundle”) that is suitable for low-light applications in astronomy. The most successful survey instruments at optical-infrared wavelengths today have obtained data on up to a million celestial sources using hundreds of multimode fibre...

  6. Session 21.2 - Measurement of Light at Night

    Science.gov (United States)

    Wainscoat, Richard J.

    2016-10-01

    The introduction of the mercury vapor lamp for general lighting in the 1930s probably marked the beginning of significant light pollution. Lighting levels have increased slowly, year-to-year, with sky brightness levels increasing only slowly on timescales of a year; no measurement protocols or instruments existed to quantify this increase. However, on timescales of 10-20 years, or on generational timescales, the increases in night sky levels, particularly in urban areas, have been dramatic. Younger people speak with their parents or grandparents who remark how beautiful the sky used to be, and how many stars they could see when they when they were younger. Older people can themselves remember how many stars were visible in the sky when they were younger. Whole generations of children now grow up without ever seeing the Milky Way. Society has not had tools to easily measure sky brightness, and monitoring from space has only recently become available. A subtle increase of 10% sky brightness per year, for example, is not noticeable to the human eye on the time scale of a year, and has been tolerated by society. But such an increase compounds to an increase of a factor 2.6 in 10 years, 6.7 in 20 years, and a factor 45 in 40 years, corresponding to a dramatic increase in sky brightness, an almost complete loss in ability to see faint objects in the night sky, and rendering the sky unusable for most forms of astronomy. The most striking examples are the urban observatories found in many major cities that can no longer be used. Session 2 was primarily focused on measurement of light at night, with an emphasis on measurement of light pollution. It comprised of 6 papers that are summarized below. Over the last decade, our ability to measure light pollution has grown tremendously, and the instrumentation needed to produce reliable quantitative measurements has become much more affordable, and now includes consumer grade digital cameras and even smart phones. During this same

  7. Instrumentation and control strategies for an integral pressurized water reactor

    Directory of Open Access Journals (Sweden)

    Belle R. Upadhyaya

    2015-03-01

    Full Text Available Several vendors have recently been actively pursuing the development of integral pressurized water reactors (iPWRs that range in power levels from small to large reactors. Integral reactors have the features of minimum vessel penetrations, passive heat removal after reactor shutdown, and modular construction that allow fast plant integration and a secure fuel cycle. The features of an integral reactor limit the options for placing control and safety system instruments. The development of instrumentation and control (I&C strategies for a large 1,000 MWe iPWR is described. Reactor system modeling—which includes reactor core dynamics, primary heat exchanger, and the steam flashing drum—is an important part of I&C development and validation, and thereby consolidates the overall implementation for a large iPWR. The results of simulation models, control development, and instrumentation features illustrate the systematic approach that is applicable to integral light water reactors.

  8. Conduction cooled compact laser for chemcam instrument

    Science.gov (United States)

    Faure, B.; Saccoccio, M.; Maurice, S.; Durand, E.; Derycke, C.

    2017-11-01

    A new conduction cooled compact laser for Laser Induced Breakdown Spectroscopy (LIBS) on Mars is presented. The laser provides pulses with energy higher than 30mJ at 1μm of wavelength with a good spatial quality. Three development prototypes of this laser have been built and functional and environmental tests have been done. Then, the Qualification and Flight models have been developed and delivered. A spare model is now developed. This laser will be mounted on the ChemCam Instrument of the NASA mission MSL 2009. ChemCam Instrument is developed in collaboration between France (CESR and CNES) and USA (LANL). The goal of this Instrument is to study the chemical composition of Martian rocks. A laser source (subject of this presentation) emits a pulse which is focused by a telescope. It creates a luminous plasma on the rock; the light of this plasma is then analysed by three spectrometers to obtain information on the composition of the rock. The laser source is developed by the French company Thales Laser, with a technical support from CNES and CESR. This development is funded by CNES. The laser is compact, designed to work in burst mode. It doesn't require any active cooling.

  9. Highly integrated Pluto payload system (HIPPS): a sciencecraft instrument for the Pluto mission

    Science.gov (United States)

    Stern, S. Alan; Slater, David C.; Gibson, William; Reitsema, Harold J.; Delamere, W. Alan; Jennings, Donald E.; Reuter, D. C.; Clarke, John T.; Porco, Carolyn C.; Shoemaker, Eugene M.; Spencer, John R.

    1995-09-01

    We describe the design concept for the highly integrated Pluto payload system (HIPPS): a highly integrated, low-cost, light-weight, low-power instrument payload designed to fly aboard the proposed NASA Pluto flyby spacecraft destined for the Pluto/Charon system. The HIPPS payload is designed to accomplish all of the Pluto flyby prime (IA) science objectives, except radio science, set forth by NASA's Outer Planets Science Working Group (OPSWG) and the Pluto Express Science Definition Team (SDT). HIPPS contains a complement of three instrument components within one common infrastructure; these are: (1) a visible/near UV CCD imaging camera; (2) an infrared spectrograph; and (3) an ultraviolet spectrograph. A detailed description of each instrument is presented along with how they will meet the IA science requirements.

  10. Cell sorting using efficient light shaping approaches

    DEFF Research Database (Denmark)

    Banas, Andrew; Palima, Darwin; Villangca, Mark Jayson

    2016-01-01

    distributions aimed at the positions of the detected cells. Furthermore, the beam shaping freedom provided by GPC can allow optimizations in the beam’s propagation and its interaction with the catapulted cells. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading...... is gentler, less invasive and more economical compared to conventional FACS systems. As cells are less responsive to plastic or glass beads commonly used in the optical manipulation literature, and since laser safety would be an issue in clinical use, we develop efficient approaches in utilizing lasers...... and light modulation devices. The Generalized Phase Contrast (GPC) method that can be used for efficiently illuminating spatial light modulators or creating well-defined contiguous optical traps is supplemented by diffractive techniques capable of integrating the available light and creating 2D or 3D beam...

  11. System automation for a bacterial colony detection and identification instrument via forward scattering

    International Nuclear Information System (INIS)

    Bae, Euiwon; Hirleman, E Daniel; Aroonnual, Amornrat; Bhunia, Arun K; Robinson, J Paul

    2009-01-01

    A system design and automation of a microbiological instrument that locates bacterial colonies and captures the forward-scattering signatures are presented. The proposed instrument integrates three major components: a colony locator, a forward scatterometer and a motion controller. The colony locator utilizes an off-axis light source to illuminate a Petri dish and an IEEE1394 camera to capture the diffusively scattered light to provide the number of bacterial colonies and two-dimensional coordinate information of the bacterial colonies with the help of a segmentation algorithm with region-growing. Then the Petri dish is automatically aligned with the respective centroid coordinate with a trajectory optimization method, such as the Traveling Salesman Algorithm. The forward scatterometer automatically computes the scattered laser beam from a monochromatic image sensor via quadrant intensity balancing and quantitatively determines the centeredness of the forward-scattering pattern. The final scattering signatures are stored to be analyzed to provide rapid identification and classification of the bacterial samples

  12. IXPE: The Imaging X-ray Polarimetry Explorer, Implementing a Dedicated Polarimetry Mission

    Science.gov (United States)

    Ramsey, Brian

    2014-01-01

    Only a few experiments have conducted x-ray polarimetry of cosmic sources since Weisskopf et al confirmed the 19% polarization of the Crab Nebula with the Orbiting Solar Observatory (OSO-8) in the 70's center dot The challenge is to measure a faint polarized component against a background of non-polarized signal (as well as the other, typical background components) center dot Typically, for a few % minimum detectable polarization, 106 photons are required. center dot So, a dedicated mission is vital with instruments that are designed specifically to measure polarization (with minimal systematic effects) Over the proposed mission life (2- 3 years), IXPE will first survey representative samples of several categories of targets: magnetars, isolated pulsars, pulsar wind nebula and supernova remnants, microquasars, active galaxies etc. The survey results will guide detailed follow-up observations. Precise calibration of IXPE is vital to ensuring sensitivity goals are met. The detectors will be characterized in Italy, and then a full calibration of the complete instrument will be performed at MSFC's stray light facility. Polarized flux at different energies Heritage: X-ray Optics at MSFC polarimetry mission.

  13. [An optical-fiber-sensor-based spectrophotometer for soil non-metallic nutrient determination].

    Science.gov (United States)

    He, Dong-xian; Hu, Juan-xiu; Lu, Shao-kun; He, Hou-yong

    2012-01-01

    In order to achieve rapid, convenient and efficient soil nutrient determination in soil testing and fertilizer recommendation, a portable optical-fiber-sensor-based spectrophotometer including immersed fiber sensor, flat field holographic concave grating, and diode array detector was developed for soil non-metallic nutrient determination. According to national standard of ultraviolet and visible spectrophotometer with JJG 178-2007, the wavelength accuracy and repeatability, baseline stability, transmittance accuracy and repeatability measured by the prototype instrument were satisfied with the national standard of III level; minimum spectral bandwidth, noise and excursion, and stray light were satisfied with the national standard of IV level. Significant linear relationships with slope of closing to 1 were found between the soil available nutrient contents including soil nitrate nitrogen, ammonia nitrogen, available phosphorus, available sulfur, available boron, and organic matter measured by the prototype instrument compared with that measured by two commercial single-beam-based and dual-beam-based spectrophotometers. No significant differences were revealed from the above comparison data. Therefore, the optical-fiber-sensor-based spectrophotometer can be used for rapid soil non-metallic nutrient determination with a high accuracy.

  14. Information needs and instrument availability for accident management : Application to YGN 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Whan; Park, Rae Jun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Suh, Kune Yull [Seoul Nationsl University, Seoul (Korea, Republic of)

    1996-12-01

    This paper introduces the five-step methodology for identifying information needs and assessing instrument availability during the course of severe in nuclear power plants. The methodology is applied to the Yonggwang (YGN) 3 and 4 to shed light on accident management. It constructs three safety objective trees to prevent the reactor vessel failure, to prevent the containment failure, and to mitigate the fission product release from the containment. The study assesses information needs and instrument availability under severe conditions for preventing the reactor vessel failure of YGN 3 and 4, and recommends additional instruments that may prove to be vital importance in managing the accident. 6 refs., 6 figs., 3 tabs. (author).

  15. Comparison of the remaining dentin thickness in the root after hand and four rotary instrumentation techniques: an in vitro study.

    Science.gov (United States)

    Rao, M S Rama; Shameem, Abdul; Nair, Rashmi; Ghanta, Sureshbabu; Thankachan, Rekha P; Issac, Johnson K

    2013-07-01

    The aim of the present study was to compare the remaining dental thickness (RDT) in the mesiobuccal root of mandibular first molars at 3 and 7 mm from the anatomic apex after instrumentation with ProTaper, light speed LSX, K3 and M2 and to compare with that of K-files. In this study, 60 extracted, untreated human mandibular first molars with fully formed apices, with curvature less than 35° and no root resorption were used. Prepared specimens were cut horizontally at 3 and 7 mm short of anatomic apex. The least dentin thickness from canal to external root surface was observed under 3× magnification and recorded using Clemax measuring tool and the sections were reassembled. Group I-instrumentation with ProTaper, group II-instrumentation with K3, group III-instrumentation with Light Speed LSX, group IV-instrumentation with M2 and group V- instrumentation with K-files and RDT was measured. Results showed that group V removed lesser amount of dentin compared to all other groups while all the three instrumentation techniques removed almost equal amount of dentin apically. Cleaning and shaping of the root canal space involves the elimination of pathogenic contents as well as attaining a uniform specific shape. However, the RDT following the use of various intraradicular procedures is an important factor to be considered as an iatrogenic cause that may result in root fracture. To avoid this, newer rotary instruments are being introduced.

  16. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  17. Nuclear and fundamental physics instrumentation for the ANS project

    International Nuclear Information System (INIS)

    Robinson, S.J.; Faust, H.; Piotrowski, A.E.

    1996-05-01

    This report summarizes work carried out during the period 1991-1995 in connection with the refinement of the concepts and detailed designs for nuclear and fundamental physics research instrumentation at the proposed Advanced Neutron source at Oak Ridge National Laboratory. Initially, emphasis was placed on refining the existing System Design Document (SDD-43) to detail more accurately the needs and interfaces of the instruments that are identified in the document. The conceptual designs of these instruments were also refined to reflect current thinking in the field of nuclear and fundamental physics. In particular, the on-line isotope separator (ISOL) facility design was reconsidered in the light of the development of interest in radioactive ion beams within the nuclear physics community. The second stage of this work was to define those instrument parameters that would interface directly with the reactor systems so that these parameters could be considered for the ISOL facility and particularly for its associated ion source. Since two of these options involved ion sources internal to the long slant beam tube, these were studied in detail. In addition, preliminary work was done to identify the needs for the target holder and changing facility to be located in the tangential through-tube. Because many of the planned nuclear and fundamental physics instruments have similar needs in terms of detection apparatus, some progress was also made in defining the parameters for these detectors. 21 refs., 32 figs., 2 tabs

  18. Evaluation of a reconfigurable portable instrument for copper determination based on luminescent carbon dots.

    Science.gov (United States)

    Salinas-Castillo, Alfonso; Morales, Diego P; Lapresta-Fernández, Alejandro; Ariza-Avidad, María; Castillo, Encarnación; Martínez-Olmos, Antonio; Palma, Alberto J; Capitan-Vallvey, Luis Fermin

    2016-04-01

    A portable reconfigurable platform for copper (Cu(II)) determination based on luminescent carbon dot (Cdots) quenching is described. The electronic setup consists of a light-emitting diode (LED) as the carbon dot optical exciter and a photodiode as a light-to-current converter integrated in the same instrument. Moreover, the overall analog conditioning is simply performed with one integrated solution, a field-programmable analog array (FPAA), which makes it possible to reconfigure the filter and gain stages in real time. This feature provides adaptability to use the platform as an analytical probe for carbon dots coming from different batches with some variations in luminescence characteristics. The calibration functions obtained that fit a modified Stern-Volmer equation were obtained using luminescence signals from Cdots quenching by Cu(II). The analytical applicability of the reconfigurable portable instrument for Cu(II) using Cdots has been successfully demonstrated in tap water analysis.

  19. Dynamic Camouflage in Benthic and Pelagic Cephalopods: An Interdisciplinary Approach to Crypsis Based on Color, Reflection, and Bioluminescence

    Science.gov (United States)

    2012-09-30

    cruise. 4 Figure 1: Hatchling cuttlefish on a dynamic background of varying intensities and spatial frequencies. The background changed in...captured as a reflectance map . A pinhole aperture is used to block light from off-axis sample points and stray light. The available range for both...image processing techniques (figure 8) to determine the variability and the areas of change in individual animal responses a) over an hour period on

  20. Vertically aligned carbon nanotubes black coatings from roll-to-roll deposition process

    Science.gov (United States)

    Goislard de Monsabert, Thomas; Papciak, L.; Sangar, A.; Descarpentries, J.; Vignal, T.; de Longiviere, Xavier; Porterat, D.; Mestre, Q.; Hauf, H.

    2017-09-01

    Vertically aligned carbon nanotubes (VACNTs) have recently attracted growing interest as a very efficient light absorbing material over a broad spectral range making them a superior coating in space optics applications such as radiometry, optical calibration, and stray light elimination. However, VACNT coatings available to-date most often result from batch-to-batch deposition processes thus potentially limiting the manufacturing repeatability, substrate size and cost efficiency of this material.

  1. Proton radiation effects on the optical properties of vertically aligned carbon nanotubes

    Science.gov (United States)

    Kuhnhenn, J.; Khavrus, V.; Leonhardt, A.; Eversheim, D.; Noll, C.; Hinderlich, S.; Dahl, A.

    2017-11-01

    This paper discusses proton-induced radiation effects in vertically aligned carbon nanotubes (VA-CNT). VACNTs exhibit extremely low optical reflectivity which makes them interesting candidates for use in spacecraft stray light suppression. Investigating their behavior in space environment is a precondition for the implementation on a satellite.

  2. Thomson scattering using an atomic notch filter

    NARCIS (Netherlands)

    Bakker, L.P.; Freriks, J.M.; Hoog, de F.J.; Kroesen, G.M.W.

    2000-01-01

    One of the biggest problems in performing Thomson scattering experiments in low-density plasmas is the very high stray light intensity in comparison with the Thomson scattering intensity. This problem is especially present in fluorescent lamps because of the proximity of the glass tube. We propose

  3. In-situ measurement of the light attenuation in liquid argon in the GERDA cryostat

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Birgit [TU Dresden, Institut fuer Kern- und Teilchenphysik (Germany); Collaboration: GERDA-Collaboration

    2016-07-01

    GERDA is an experiment searching for neutrinoless double beta decay in {sup 76}Ge. It operates the enriched germanium detectors bare in liquid argon (LAr), which serves both as a coolant and a shield for external radiation. Phase II of GERDA aims for an exposure of 100 kg . yr with a background index (BI) of 10{sup -3} cts/(kg . yr . keV). One of the major improvements to further reduce the BI comes from the instrumentation of the LAr to readout its scintillation light. The attenuation of the scintillation light in LAr limits the effective active volume of the LAr veto and is therefore a key parameter to characterize the instrumentation. In order to measure the light attenuation in LAr, a setup was designed that could be deployed directly into the GERDA cryostat. This setup contains a movable beta source and a PMT to detect the scintillation light at different distances. The talk will present the acquired data as well as a detailed description of the performed analysis technique and the current results.

  4. Instrument Remote Control via the Astronomical Instrument Markup Language

    Science.gov (United States)

    Sall, Ken; Ames, Troy; Warsaw, Craig; Koons, Lisa; Shafer, Richard

    1998-01-01

    The Instrument Remote Control (IRC) project ongoing at NASA's Goddard Space Flight Center's (GSFC) Information Systems Center (ISC) supports NASA's mission by defining an adaptive intranet-based framework that provides robust interactive and distributed control and monitoring of remote instruments. An astronomical IRC architecture that combines the platform-independent processing capabilities of Java with the power of Extensible Markup Language (XML) to express hierarchical data in an equally platform-independent, as well as human readable manner, has been developed. This architecture is implemented using a variety of XML support tools and Application Programming Interfaces (API) written in Java. IRC will enable trusted astronomers from around the world to easily access infrared instruments (e.g., telescopes, cameras, and spectrometers) located in remote, inhospitable environments, such as the South Pole, a high Chilean mountaintop, or an airborne observatory aboard a Boeing 747. Using IRC's frameworks, an astronomer or other scientist can easily define the type of onboard instrument, control the instrument remotely, and return monitoring data all through the intranet. The Astronomical Instrument Markup Language (AIML) is the first implementation of the more general Instrument Markup Language (IML). The key aspects of our approach to instrument description and control applies to many domains, from medical instruments to machine assembly lines. The concepts behind AIML apply equally well to the description and control of instruments in general. IRC enables us to apply our techniques to several instruments, preferably from different observatories.

  5. Iterative noise removal from temperature and density profiles in the TJ-II Thomson scattering

    International Nuclear Information System (INIS)

    Farias, G.; Dormido-Canto, S.; Vega, J.; Santos, M.; Pastor, I.; Fingerhuth, S.; Ascencio, J.

    2014-01-01

    TJ-II Thomson Scattering diagnostic provides temperature and density profiles of plasma. The CCD camera acquires images that are corrupted with some kind of noise called stray-light. This noise degrades both image contrast and measurement accuracy, which could produce unreliable profiles of the diagnostic. So far, several approaches have been applied in order to decrease the noise in the TJ-II Thomson scattering images. Since the presence of the noise is not global but located in some particular regions of the image, advanced processing techniques are needed. However such methods require of manual fine-tuning of parameters to reach a good performance. In this contribution, an iterative image processing approach is applied in order to reduce the stray light effects in the images of the TJ-II Thomson scattering diagnostic. The proposed solution describes how the noise can be iteratively reduced in the images when a key parameter is automatically adjusted during the iterative process

  6. Iterative noise removal from temperature and density profiles in the TJ-II Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Farias, G., E-mail: gonzalo.farias@ucv.cl [Pontificia Universidad Católica de Valparaíso, Av. Brasil 2147, Valparaíso (Chile); Dormido-Canto, S., E-mail: sebas@dia.uned.es [Departamento de Informática y Automática, UNED, 28040 Madrid (Spain); Vega, J., E-mail: jesus.vega@ciemat.es [Asociación EURATOM/CIEMAT para Fusión, Avd. Complutense 22, 28040 Madrid (Spain); Santos, M., E-mail: msantos@ucm.es [Departamento de Arquitectura de Computadores y Automática, Universidad Complutense de Madrid, 28040 Madrid (Spain); Pastor, I., E-mail: ignacio.pastor@ciemat.es [Asociación EURATOM/CIEMAT para Fusión, Avd. Complutense 22, 28040 Madrid (Spain); Fingerhuth, S., E-mail: sebastian.fingerhuth@ucv.cl [Pontificia Universidad Católica de Valparaíso, Av. Brasil 2147, Valparaíso (Chile); Ascencio, J., E-mail: j_ascencio21@hotmail.com [Pontificia Universidad Católica de Valparaíso, Av. Brasil 2147, Valparaíso (Chile)

    2014-05-15

    TJ-II Thomson Scattering diagnostic provides temperature and density profiles of plasma. The CCD camera acquires images that are corrupted with some kind of noise called stray-light. This noise degrades both image contrast and measurement accuracy, which could produce unreliable profiles of the diagnostic. So far, several approaches have been applied in order to decrease the noise in the TJ-II Thomson scattering images. Since the presence of the noise is not global but located in some particular regions of the image, advanced processing techniques are needed. However such methods require of manual fine-tuning of parameters to reach a good performance. In this contribution, an iterative image processing approach is applied in order to reduce the stray light effects in the images of the TJ-II Thomson scattering diagnostic. The proposed solution describes how the noise can be iteratively reduced in the images when a key parameter is automatically adjusted during the iterative process.

  7. A development optical course based on optical fiber white light interference

    Science.gov (United States)

    Jiang, Haili; Sun, Qiuhua; Zhao, Yancheng; Li, Qingbo

    2017-08-01

    The Michelson interferometer is a very important instrument in optical part for college physics teaching. But most students only know the instrument itself and don't know how to use it in practical engineering problems. A case about optical fiber white light interference based on engineering practice was introduced in the optical teaching of college physics and then designed a development course of university physical optics part. This system based on low-coherence white light interferometric technology can be used to measure distribution strain or temperature. It also could be used in the case of temperature compensation mode.This teaching design can use the knowledge transfer rule to enable students to apply the basic knowledge in the university physics to the new knowledge domain, which can promote the students' ability of using scientific methods to solve complex engineering problems.

  8. A new time-of-flight instrument for quantitative surface analysis

    International Nuclear Information System (INIS)

    Veryovkin, Igor V.; Calaway, Wallis F.; Moore, Jerry F.; Pellin, Michael J.; Burnett, Donald S.

    2004-01-01

    A new generation of time-of-flight mass spectrometers that implement ion sputtering and laser desorption for probing solid samples and can operate in regimes of laser post-ionization secondary neutral mass spectrometry and secondary ion mass spectrometry is being developed at Argonne National Laboratory. These new instruments feature novel ion optical systems for efficient extraction of ions from large laser post-ionization volumes and for lossless transport of these ions to detectors. Another feature of this design is a new in-vacuum all-reflecting optical microscope with 0.5-μm resolution. Advanced ion and light optics and three ion sources, including a liquid metal ion gun (focusable to 50 nm) and a low energy ion gun, give rise to an instrument capable of quantitative analyses of samples for the most challenging applications, such as determining elemental concentrations in shallow implants at ultra-trace levels (for example, solar wind samples delivered by NASA Genesis mission) and analyzing individual sub-micrometer particles on a sample stage (such as, interstellar dust delivered by NASA Stardust mission). Construction of a prototype instrument has been completed and testing is underway. A more advanced instrument of similar design is under construction. The overall design of the new instrument and the innovations that make it unique are outlined. Results of the first tests to characterize its analytical capabilities are presented also

  9. FMIT diagnostic instrumentation

    International Nuclear Information System (INIS)

    Gilpatrick, J.D.; Chamberlin, D.D.

    1985-01-01

    The Fusion Materials Irradiation Test facility (FMIT) cw prototype accelerator has noninterceptive beamline instrumentation to measure beam parameters. The transverse emittances and beam profiles are measured with an array of photodiode sensors viewing light emitted from the beam region. Tomographic reconstructions of both spatial-density distributions and of transverse-emittance distributions are performed throughout a quadrupole focusing section. Beam bunches passing through capacitive probes produce bipolar waveforms whose zero crossing corresponds to the bunch's longitudinal centroid. By measuring the time required for a bunch to travel the known distance between two probes, velocity and energy are determined. A toroidal transformer measures the average ac beam current. Beam spill is measured by a set of movable jaws that intercept the beam edges. Each jaw contains a water flow channel whose flow rate and differential temperature are measured to derive a transverse power distribution. Beam centroid position is measured by a four-lobe, magnetic-loop pickup. 5 refs., 6 figs

  10. The evaluation of equipment and Instrumentation Reliability Factors on Power Reactor

    International Nuclear Information System (INIS)

    Supriatna, Piping; Karlina, Itjeu; Widagdo, Suharyo; Santosa, Kussigit; Darlis; Sudiyono, Bambang; Yuniyanta, Sasongko; Sudarmin

    1999-01-01

    Equipment and instrumentation reliability on type power reactor control room was determined by its pattern and design. the principle of ergonomy applied on equipment and instrumentation layout in this ABWR type reactor are geometric pattern appropriate with economic body motion, average anthropometry data of operator especially operator hand-reach, range of vision, angle of vision, lighting, color arrangement and harmony as will as operator case in operating the equipment system. Limitation criteria of the parameter mentioned above are based on EPRI NP-3659, NURG 0700, and NUREG/CR-3331 documents. Besides that, the (working) physical environment parameter factor of the control room must be designed in order to fulfil the standard criteria of ergonomic condition based on NUREG-0800. The reliability evaluation of equipment and instrumentation system also occurs observed from man machine interaction side which happen between operator and equipment and instrumentation in the ABWR type power reactor control room. From the MMI analysis can be known the working failure possibility which is caused by the operator. The evaluation result of equipment and instrumentation reliability on ABWR type power reactor control room showed that the design of this ABWR control room is good and fulfils the ergonomy standard criteria have been determined

  11. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  12. EPRI instruments reach commercial market

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    The Electric Power Research Institute has developed instruments capable of verifying time responses of power plant pressure sensors and temperature sensors. A patent is pending on the pressure-sensor device, and the temperature-sensor device is already commercially available. The devices, EPRI's first hardware products to be marketed, are the result of research to find technological solutions to the problems of knowing the time period when temperature and pressure changes occur in light water reactors. The hydraulic pressure-sensor device is a portable unit that can conveniently test equipment in place. Utilities can obtain detailed information from EPRI's project report to construct their own. The loop current step response (LCSR), measuring resistance temperature, is also a compact system suitable for in-plant testing

  13. Operational experience with synchrotron light interferometers for CEBAF experimental beam lines

    Energy Technology Data Exchange (ETDEWEB)

    Pavel Chevtsov

    2006-10-24

    Beam size and energy spread monitoring systems based on Synchrotron Light Interferometers (SLI) have been in operations at Jefferson Lab for several years. A non-invasive nature and a very high (a few mm) resolution of SLI make these instruments valuable beam diagnostic tools for the CEBAF accelerator. This presentation describes the evolution of the Synchrotron Light Interferometer at Jefferson Lab and highlights our extensive experience in the installation and operation of the SLI for CEBAF experimental beam lines.

  14. Advanced light water reactors for the nineties

    International Nuclear Information System (INIS)

    Ross, F.A.; Sugnet, W.R.

    1987-01-01

    The EPRI/Industry advanced light water reactor (ALWR) program and the US Department of Energy ALWR program are closely coordinated to meet the common objective which is the availability of improved and simplified light water reactor plants that may be ordered in the next decade to meet new or replacement capacity requirements. The EPRI/Industry objectives, program participants, and foreign participants, utility requirements document, its organization and content, small plant conceptual design program, the DOE ALWR program, design verification program, General Electric ABWR design features, Combustion Engineering system design, mid-size plant development, General Electric SBWR objectives, Westinghouse/Burns and Roe design objectives, construction improvement, and improved instrumentation and control are discussed in the paper

  15. Instrumentation and Controls evaluation for space nuclear power systems

    International Nuclear Information System (INIS)

    Anderson, J.L.; Oakes, L.C.

    1984-01-01

    Design of control and protection systems should be coordinated with the design of the neutronic, thermal-hydraulic, and mechanical aspects of the core and plant at the earliest possible stage of concept development. An integrated systematic design approach is necessary to prevent uncoordinated choices in one technology area from imposing impractical or impossible requirements in another. Significant development and qualification will be required for virtually every aspect of reactor control and instrumentation. In-core instrumentation widely used in commercial light water reactors will not likely be usable in the higher temperatures of a space power plant. Thermocouples for temperature measurement and gamma thermometers for flux measurement appear to be the only viable candidates. Recent developments in ex-core neutron detectors may provide achievable alternatives to in-core measurements. Reliable electronic equipment and high-temperature actuators will require major development efforts

  16. The Pre-Injector Linac for the Diamond Light Source

    CERN Document Server

    Christou, C

    2004-01-01

    The Diamond Light Source is a new medium-energy high brightness synchrotron light facility which is under construction on the Rutherford Appleton Laboratory site in the U.K. The accelerator facility can be divided into three major components; a 3 GeV 561 m circumference storage ring, a full-energy booster synchrotron and a 100 MeV pre-injector linac. This paper describes the linac design and plans for operation. The linac is supplied by ACCEL Instruments GmbH under a turn-key contract, with Diamond Light Source Ltd. providing linac beam diagnostics, control system hardware and standard vacuum components. Commissioning of the linac will take place in early 2005 and user operation of the facility will commence in 2007.

  17. Highly efficient blazed grating with multilayer coating for tender X-ray energies

    NARCIS (Netherlands)

    Senf, F.; Bijkerk, Frederik; Eggenstein, F.; Gwalt, G.; Huang, Qiushi; van de Kruijs, Robbert Wilhelmus Elisabeth; Kutz, O.; Lemke, S.; Louis, Eric; Mertin, M.; Packe, I.; Rudolph, I.; Schafers, F.; Siewert, F.; Sokolov, A.; Sturm, Jacobus Marinus; Waberski, C.; Wang, Z.; Wolf, J.; Zeschke, T.; Erko, A.

    2016-01-01

    For photon energies of 1 – 5 keV, blazed gratings with multilayer coating are ideally suited for the suppression of stray and higher orders light in grating monochromators. We developed and characterized a blazed 2000 lines/mm grating coated with a 20 period Cr/C- multilayer. The multilayer

  18. Sensitivity of the OMI ozone profile retrieval (OMO3PR) to a priori assumptions

    NARCIS (Netherlands)

    Mielonen, T.; De Haan, J.F.; Veefkind, J.P.

    2014-01-01

    We have assessed the sensitivity of the operational OMI ozone profile retrieval (OMO3PR) algorithm to a number of a priori assumptions. We studied the effect of stray light correction, surface albedo assumptions and a priori ozone profiles on the retrieved ozone profile. Then, we studied how to

  19. Thomson scattering in a low-pressure argon mercury positive column

    NARCIS (Netherlands)

    Bakker, L.P.; Kroesen, G.M.W.

    2000-01-01

    The electron density and the electron temperature in a low-pressure argon mercury positive column are determined using Thomson scattering. Special attention has been given to the stray light reduction in the Thomson scattering setup. The results are obtained in a discharge tube with a 26 mm diam, 5

  20. Thomson scattering in a low-pressure neon mercury positive column

    NARCIS (Netherlands)

    Bakker, L.P.; Kroesen, G.M.W.

    2001-01-01

    The electron density and the electron temperature in a low-pressure neon mercury positive column are determined using Thomson scattering. Special attention has been given to the stray light reduction in the Thomson scattering setup. The results are obtained in a discharge tube with a 26 mm diam, 10

  1. A new approach to preparation of standard LEDs for luminous intensity and flux measurement of LEDs

    Science.gov (United States)

    Park, Seung-Nam; Park, Seongchong; Lee, Dong-Hoon

    2006-09-01

    This work presents an alternative approach for preparing photometric standard LEDs, which is based on a novel functional seasoning method. The main idea of our seasoning method is simultaneously monitoring the light output and the junction voltage to obtain quantitative information on the temperature dependence and the aging effect of the LED emission. We suggested a general model describing the seasoning process by taking junction temperature variation and aging effect into account and implemented a fully automated seasoning facility, which is capable of seasoning 12 LEDs at the same time. By independent measurements of the temperature dependence, we confirmed the discrepancy of the theoretical model to be less than 0.5 % and evaluate the uncertainty contribution of the functional seasoning to be less than 0.5 % for all the seasoned samples. To demonstrate assigning the reference value to a standard LED, the CIE averaged LED intensity (ALI) of the seasoned LEDs was measured with a spectroradiometer-based instrument and the measurement uncertainty was analyzed. The expanded uncertainty of the standard LED prepared by the new approach amounts to be 4 % ~ 5 % (k=2) depending on color without correction of spectral stray light in the spectroradiometer.

  2. Design and characterization of a low cost CubeSat multi-band optical receiver to map water ice on the lunar surface for the Lunar Flashlight mission

    Science.gov (United States)

    Vinckier, Quentin; Crabtree, Karlton; Paine, Christopher G.; Hayne, Paul O.; Sellar, Glenn R.

    2017-08-01

    Lunar Flashlight is an innovative NASA CubeSat mission dedicated to mapping water ice in the permanently shadowed regions of the Moon, which may act as cold traps for volatiles. To this end, a multi-band reflectometer will be sent to orbit the Moon. This instrument consists of an optical receiver aligned with four lasers, each of which emits sequentially at a different wavelength in the near-infrared between 1 μm and 2 μm. The receiver measures the laser light reflected from the lunar surface; continuum/absorption band ratios are then analyzed to quantify water ice in the illuminated spot. Here, we present the current state of the optical receiver design. To optimize the optical signal-to-noise ratio, we have designed the receiver so as to maximize the laser signal collected, while minimizing the stray light reaching the detector from solarilluminated areas of the lunar surface outside the field-of-view, taking into account the complex lunar topography. Characterization plans are also discussed. This highly mass- and volume-constrained mission will demonstrate several firsts, including being one of the first CubeSats performing science measurements beyond low Earth orbit.

  3. Conjugation of fiber-coupled wide-band light sources and acousto-optical spectral elements

    Science.gov (United States)

    Machikhin, Alexander; Batshev, Vladislav; Polschikova, Olga; Khokhlov, Demid; Pozhar, Vitold; Gorevoy, Alexey

    2017-12-01

    Endoscopic instrumentation is widely used for diagnostics and surgery. The imaging systems, which provide the hyperspectral information of the tissues accessible by endoscopes, are particularly interesting and promising for in vivo photoluminescence diagnostics and therapy of tumour and inflammatory diseases. To add the spectral imaging feature to standard video endoscopes, we propose to implement acousto-optical (AO) filtration of wide-band illumination of incandescent-lamp-based light sources. To collect maximum light and direct it to the fiber-optic light guide inside the endoscopic probe, we have developed and tested the optical system for coupling the light source, the acousto-optical tunable filter (AOTF) and the light guide. The system is compact and compatible with the standard endoscopic components.

  4. Green lights program in China

    Energy Technology Data Exchange (ETDEWEB)

    Dadi, Zhuo; Hong, Liu [Beijing Energy Efficiency Center (China)

    1996-12-31

    In China`s 9th 5-year plan (1996-2000), the Chinese government has placed high priority on energy conservation. The China Green Lights Program (CGLP) is listed as one of the key projects of energy conservation. The basic strategy of the CGLP is to mobilise all of the potential contributors to participate in the program, and to use market signals and supplementary non-market instruments to facilitate its implementation. Governmental funds and loans will be used as seed money to attract private participation in the program. The program contains the following elements: (1) Information dissemination to educate the public on the economic and other values of the program and to provide CGLP information to increase consumer awareness and, as a result, increase the demand for energy-efficient lighting systems. (2) Development of standards and codes for lighting systems, establishment of product specifications, and enforcement of product standards. (3) Development of quality certification and labelling system to provide assurances to consumers that the products they are purchasing will meet their performance and cost saving expectations. (4) Highlighted support and financing for production technology development and production capacity expansion. (5) Demonstration and pilot projects to boost consumer confidence in green lighting systems and to demonstrate new production technologies and processes. (6) International co-operation to expand the international exchange and absorb advanced technology and experience for implementation of the China Green Lights Program.

  5. Instrumental interaction

    OpenAIRE

    Luciani , Annie

    2007-01-01

    International audience; The expression instrumental interaction as been introduced by Claude Cadoz to identify a human-object interaction during which a human manipulates a physical object - an instrument - in order to perform a manual task. Classical examples of instrumental interaction are all the professional manual tasks: playing violin, cutting fabrics by hand, moulding a paste, etc.... Instrumental interaction differs from other types of interaction (called symbolic or iconic interactio...

  6. Comparison between rotary and manual instrumentation in primary teeth.

    Science.gov (United States)

    Crespo, S; Cortes, O; Garcia, C; Perez, L

    2008-01-01

    The aim of this study was to compare the efficiency in both, preparation time and root canal shape, when using the Nickel Titanium (Ni-Ti) rotary and K-Files hand instrumentation on root canal preparation of single rooted primary teeth. Sixty single rooted primary teeth were selected and divided into two equal groups: Group (I) 30 teeth instrumented with manual K-files and group (II) 30 teeth instrumented with Ni-Ti rotary files (ProFile 0.04). Instrumentation times were calculated and root canal impressions were taken with light bodied silicone in order to evaluate the shape. The data was analyzed with SPSS program using the t-test and the Chi-square test to compare their means. The preparation time with group (I) K-files was significantly higher than in group (II) rotary files (ProFile 0.04), with a p= .005. The ProFile system showed a significantly more favorable canal taper when compared to the K-files system (P= .002). The use of rotary files in primary teeth has several advantages when compared with manual K files: the efficiency in both, preparation time and root canal shape. 1. A decreased working time, that helps maintain patient cooperation by diminishing the potential for tiredness. 2. The shape of the root canal is more conical, favoring a higher quality of the root canal filling, and increasing clinical success.

  7. Instrumentation development

    International Nuclear Information System (INIS)

    Ubbes, W.F.; Yow, J.L. Jr.

    1988-01-01

    Instrumentation is developed for the Civilian Radioactive Waste Management Program to meet several different (and sometimes conflicting) objectives. This paper addresses instrumentation development for data needs that are related either directly or indirectly to a repository site, but does not touch on instrumentation for work with waste forms or other materials. Consequently, this implies a relatively large scale for the measurements, and an in situ setting for instrument performance. In this context, instruments are needed for site characterization to define phenomena, develop models, and obtain parameter values, and for later design and performance confirmation testing in the constructed repository. The former set of applications is more immediate, and is driven by the needs of program design and performance assessment activities. A host of general technical and nontechnical issues have arisen to challenge instrumentation development. Instruments can be classed into geomechanical, geohydrologic, or other specialty categories, but these issues cut across artificial classifications. These issues are outlined. Despite this imposing list of issues, several case histories are cited to evaluate progress in the area

  8. High Resolution Near Infrared Spectrometer to Study the Zodiacal Light Spectrum

    Science.gov (United States)

    Kutyrev, Alexander; Arendt, R.; Dwek, E.; Moseley, S. H.; Silverberg, R.; Rapchun, D.

    2007-12-01

    We are developing a near infrared spectrometer for measuring solar absorption lines in the zodiacal light in the near infrared region. R. Reynolds at el. (2004, ApJ 612, 1206) demonstrated that observing single Fraunhofer line can be a powerful tool for extracting zodiacal light parameters based on their measurements of the profile of the Mg I line at 5184 A. We are extending this technique to the near infrared with the primary goal of measuring the absolute intensity of the zodiacal light. This measurement will provide the crucial information needed to accurately subtract zodiacal emission from the DIRBE measurements to get a much higher quality measurement of the extragalactic IR background. The instrument design is based on a dual Fabry-Perot interferometer with a narrow band filter. Its double etalon design allows to achieve high spectral contrast to reject the bright out of band telluric OH emission. High spectral contrast is absolutely necessary to achieve detection limits needed to accurately measure the intensity of the absorption line. We present the design, estimated performance of the instrument with the expected results of the observing program. The project is supported by NASA ROSES-APRA grant.

  9. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  10. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  11. Analysis of stray radiation produced by the advanced light source (1.9 GeV synchrotron radiation source) at Lawrence Berkeley Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Ajemian, Robert C. [Univ. of North Carolina, Chapel Hill, NC (United States). Dept. of Environmental Sciences and Engineering

    1995-01-01

    The yearly environmental dose equivalent likely to result at the closest site boundary from the Advanced Light Source was determined by generating multiple linear regressions. The independent variables comprised quantified accelerator operating parameters and measurements from synchronized, in-close (outside shielding prior to significant atmospheric scattering), state-of-the-art neutron remmeters and photon G-M tubes. Neutron regression models were more successful than photon models due to lower relative background radiation and redundant detectors at the site boundary. As expected, Storage Ring Beam Fill and Beam Crashes produced radiation at a higher rate than gradual Beam Decay; however, only the latter did not include zero in its 95% confidence interval. By summing for all three accelerator operating modes, a combined yearly DE of 4.3 mRem/yr with a 90% CI of (0.04-8.63) was obtained. These results fall below the DOE reporting level of 10 mRem/yr and suggest repeating the study with improved experimental conditions.

  12. Analysis of stray radiation produced by the advanced light source (1.9 GeV synchrotron radiation source) at Lawrence Berkeley Laboratory

    International Nuclear Information System (INIS)

    Ajemian, R.C.

    1995-01-01

    The yearly environmental dose equivalent likely to result at the closest site boundary from the Advanced Light Source was determined by generating multiple linear regressions. The independent variables comprised quantified accelerator operating parameters and measurements from synchronized, in-close (outside shielding prior to significant atmospheric scattering), state-of-the-art neutron remmeters and photon G-M tubes. Neutron regression models were more successful than photon models due to lower relative background radiation and redundant detectors at the site boundary. As expected, Storage Ring Beam Fill and Beam Crashes produced radiation at a higher rate than gradual Beam Decay; however, only the latter did not include zero in its 95% confidence interval. By summing for all three accelerator operating modes, a combined yearly DE of 4.3 mRem/yr with a 90% CI of (0.04-8.63) was obtained. These results fall below the DOE reporting level of 10 mRem/yr and suggest repeating the study with improved experimental conditions

  13. Portable light-emitting diode-based photometer with one-shot optochemical sensors for measurement in the field.

    Science.gov (United States)

    Palma, A J; Ortigosa, J M; Lapresta-Fernández, A; Fernández-Ramos, M D; Carvajal, M A; Capitán-Vallvey, L F

    2008-10-01

    This report describes the electronics of a portable, low-cost, light-emitting diode (LED)-based photometer dedicated to one-shot optochemical sensors. Optical detection is made through a monolithic photodiode with an on-chip single-supply transimpedance amplifier that reduces some drawbacks such as leakage currents, interferences, and parasitic capacitances. The main instrument characteristics are its high light source stability and thermal correction. The former is obtained by means of the optical feedback from the LED polarization circuit, implementing a pseudo-two light beam scheme from a unique light source with a built-in beam splitter. The feedback loop has also been used to adjust the LED power in several ranges. Moreover, the low-thermal coefficient achieved (-90 ppm/degrees C) is compensated by thermal monitoring and calibration function compensation in the digital processing. The hand-held instrument directly gives the absorbance ratio used as the analytical parameter and the analyte concentration after programming the calibration function in the microcontroller. The application of this photometer for the determination of potassium and nitrate, using one-shot sensors with ionophore-based chemistries is also demonstrated, with a simple analytical methodology that shortens the analysis time, eliminating some calibrating solutions (HCl, NaOH, and buffer). Therefore, this compact instrument is suitable for real-time analyte determination and operation in the field.

  14. Evaluating public policy instruments in the Greek building sector

    International Nuclear Information System (INIS)

    Spyridaki, Niki-Artemis; Banaka, Stefania; Flamos, Alexandros

    2016-01-01

    This paper applies a multi-criteria analysis (MCA) to evaluate public policy mechanisms that foster energy efficiency and renewable energy sources in the Greek building sector, based on stakeholders’ understanding and perceptions of the functionality of policy instruments. The objective is to shed light on the implementation of currently employed policy mechanisms that aim to achieve the 2020 energy savings targets and beyond, providing useful information to policy makers for future policy (re-) formulations. In this framework, policy instruments were evaluated against process-related criteria, such as implementation costs, distributional effects, and coherence of policy processes, so as to highlight successful policy practices during their implementation phase as well as to unveil cases of policy underperformance or unintended policy outcomes. To hedge uncertainties related to policy instrument selection, the method employs probabilistic evaluations of every alternative against each criterion. The MCA results showed that the country is still missing significant energy saving opportunities that could be reached through more streamlined implementation practices and political support. In times of fiscal crisis, the Greek government should also revitalize the implementation of alternative funding mechanisms and support policy alternatives such as green public procurement, voluntary agreements, and energy performance contracting. - Highlights: • We apply an MCA analysis to evaluate EE and RES policies instruments. • We focus on the implementation stage through qualitative criteria and ordinal scales. • We use the probabilistic evaluations of each alternative against each criterion. • We provide rankings of instruments according to process related criteria. • Greece should revitalize the implementation of funding mechanisms, GPP and VAs.

  15. Performance evaluation of a vibration desensitized scanning white light interferometer

    International Nuclear Information System (INIS)

    Troutman, J; Evans, C J; Ganguly, V; Schmitz, T L

    2014-01-01

    Surface metrology instruments normally require thermal, seismic and acoustic isolation. Shop-floor metrology solutions offer reduced cost and process time. If they operate on the same principles as laboratory devices, an inherent sensitivity to vibration remains. This paper describes a methodology for evaluating ‘environmental tolerance’ and applying it to characterize a recently introduced ‘environmentally tolerant’ scanning white light interferometer (SWLI). Previously published measurements of replicated nickel reference standards on the new instrument and on a stylus profilometer showed good correlation. Surface topography repeatabilities (per ISO 25178-604:2013) were insignificantly different when evaluated on the SWLI instrument in a metrology laboratory and in a manufacturing area. Measurements of reference standards under forced vibration of the entire instrument show maximum ripple error and data dropout in regions of structural resonance. Measurements were performed with large forced horizontal and vertical sample oscillation beneath the objective, exhibiting maximum ripple error near odd integer multiples of half the instrument detector frequency. Error due to data dropout was also investigated. (paper)

  16. SuperAGILE onboard electronics and ground test instrumentation

    International Nuclear Information System (INIS)

    Pacciani, Luigi; Morelli, Ennio; Rubini, Alda; Mastropietro, Marcello; Porrovecchio, Geiland; Costa, Enrico; Del Monte, Ettore; Donnarumma, Immacolata; Evangelista, Yuri; Feroci, Marco; Lazzarotto, Francesco; Rapisarda, Massimo; Soffitta, Paolo

    2007-01-01

    In this paper we describe the electronics of the SuperAGILE X-ray imager on-board AGILE satellite and the instrumentation developed to test and improve the Front-End and digital electronics of the flight model of the imager. Although the working principle of the instrument is very well established, and the conceptual scheme simple, the budget and mechanical constraints of the AGILE small mission made necessary the introduction of new elements in SuperAGILE, regarding both the mechanics and the electronics. In fact the instrument is contained in a ∼44x44x16cm 3 volume, but the required performance is quite ambitious, leading us to equip a sensitive area of ∼1350cm 2 with 6144 Silicon μstrips detectors with a pitch of 121μm and a total length of ∼18.2cm. The result is a very light and power-cheap imager with a good sensitivity (∼15mCrab in 1 day in 15-45keV), high angular resolution (6arcmin) and gross spectral resolution. The test-equipment is versatile, and can be easily modified to test FEE based on self-triggered, data-driven and sparse-readout ASICs such as XA family chips

  17. Laser-induced emission, fluorescence and Raman hybrid setup: A versatile instrument to analyze materials from cultural heritage

    Science.gov (United States)

    Syvilay, D.; Bai, X. S.; Wilkie-Chancellier, N.; Texier, A.; Martinez, L.; Serfaty, S.; Detalle, V.

    2018-02-01

    The aim of this research project was the development of a hybrid system in laboratory coupling together three analytical techniques, namely laser-induced breakdown spectroscopy (LIBS), laser-induced fluorescence (LIF) and Raman spectroscopy in a single instrument. The rationale for combining these three spectroscopies was to identify a material (molecular and elemental analysis) without any preliminary preparation, regardless of its organic or inorganic nature, on the surface and in depth, without any surrounding light interference thanks to time resolution. Such instrumentation would allow characterizing different materials from cultural heritage. A complete study on LIBS-LIF-Raman hybrid was carried out, from its conception to instrumental achievement, in order to elaborate a strategy of analysis according to the material and to be able to address conservation issues. From an instrumental point of view, condensing the three spectroscopies was achieved by using a single laser for excitation and two spectrometers (time-integrated and not time-integrated) for light collection. A parabolic mirror was used as collecting system, while three excitation sources directed through this optical system ensured the examination of a similar probe area. Two categories of materials were chosen to test the hybrid instrumentation on cultural heritage applications (copper corrosion products and wall paintings). Some examples are reported to illustrate the wealth of information provided by the hybrid, thus demonstrating its great potential to be used for cultural heritage issues. Finally, several considerations are outlined aimed at further improving the hybrid.

  18. Prevalence of gastrointestinal parasites of stray dogs impounded by the Society for the Prevention of Cruelty to Animals (SPCA, Durban and Coast, South Africa : short communication

    Directory of Open Access Journals (Sweden)

    S. Mukaratirwa

    2010-05-01

    Full Text Available Coprological examination was used to determine the prevalence and intensity of gastrointestinal parasites of stray dogs impounded by the Society for the Prevention of Cruelty to Animals (SPCA, Durban and Coast, South Africa. Helminth and protozoan parasites were found in faeces of 240 dogs with an overall prevalence of 82.5% (helminth parasites 93.1% and protozoan parasites 6.9 %. The following parasites and their prevalences were detected; Ancylostoma sp. (53.8 %, Trichuris vulpis (7.9 %, Spirocerca lupi (5.4 %, Toxocara canis (7.9 %, Toxascaris leonina (0.4 % Giardia intestinalis (5.6 % and Isospora sp. (1.3 %. Dogs harbouring a single parasite species were more common (41.7 % than those harbouring 2 (15 % or multiple (2.1 % species. Ancylostoma sp., Toxocara canis and Giardia intestinalis have zoonotic potential and were detected in 66.7 % of the samples.

  19. Engineering design of the Regolith X-ray Imaging Spectrometer (REXIS) instrument: an OSIRIS-REx student collaboration

    Science.gov (United States)

    Jones, Michael; Chodas, Mark; Smith, Matthew J.; Masterson, Rebecca A.

    2014-07-01

    OSIRIS-REx is a NASA New Frontiers mission scheduled for launch in 2016 that will travel to the asteroid Bennu and return a pristine sample of the asteroid to Earth. The REgolith X-ray Imaging Spectrometer (REXIS) is a student collaboration instrument on-board the OSIRIS-REx spacecraft. REXIS is a NASA risk Class D instrument, and its design and development is largely student led. The engineering team consists of MIT graduate and undergraduate students and staff at the MIT Space Systems Laboratory. The primary goal of REXIS is the education of science and engineering students through participation in the development of light hardware. In light, REXIS will contribute to the mission by providing an elemental abundance map of the asteroid and by characterizing Bennu among the known meteorite groups. REXIS is sensitive to X-rays between 0.5 and 7 keV, and uses coded aperture imaging to map the distribution of iron with 50 m spatial resolution. This paper describes the science goals, concept of operations, and overall engineering design of the REXIS instrument. Each subsystem of the instrument is addressed with a high-level description of the design. Critical design elements such as the Thermal Isolation Layer (TIL), radiation cover, coded-aperture mask, and Detector Assembly Mount (DAM) are discussed in further detail.

  20. Light Diffusion in the Tropical Dry Forest of Costa Rica

    Science.gov (United States)

    Calvo-Rodriguez, S.; Sanchez-Azofeifa, G. A.

    2016-06-01

    Leaf Area Index (LAI) has been defined as the total leaf area (one-sided) in relation to the ground. LAI has an impact on tree growth and recruitment through the interception of light, which in turn affects primary productivity. Even though many instruments exist for estimating LAI from ground, they are often laborious and costly to run continuously. Measurements of LAI from the field using traditional sensors (e.g., LAI-2000) require multiple visits to the field under very specific sky conditions, making them unsuitable to operate in inaccessible areas and forests with dense vegetation, as well as areas where persistent sunny conditions are the norm like tropical dry forests. With this context, we proposed a methodology to characterize light diffusion based on NDVI and LAI measurements taken from the field in two successional stages in the tropical dry forest of Santa Rosa National Park in Costa Rica. We estimate a "K" coefficient to characterize light diffusion by the canopy, based on field NDVI measurements derived from optical phenology instruments and MODIS NDVI. From the coefficients determined, we estimated LAI values and compared them with ground measurements of LAI. In both successional stages ground measurements of LAI had no significant difference to the tower-derived LAI and the estimated LAI from MODIS NDVI.