WorldWideScience

Sample records for instrument response functions

  1. Evaluation and Monte Carlo modelling of the response function of the Leake neutron area survey instrument

    International Nuclear Information System (INIS)

    Tagziria, H.; Tanner, R.J.; Bartlett, D.T.; Thomas, D.J.

    2004-01-01

    All available measured data for the response characteristics of the Leake counter have been gathered together. These data, augmented by previously unpublished work, have been compared to Monte Carlo simulations of the instrument's response characteristics in the energy range from thermal to 20 MeV. A response function has been derived, which is recommended as the best currently available for the instrument. Folding this function with workplace energy distributions has enabled an assessment of the impact of this new response function to be made. Similar work, which will be published separately, has been carried out for the NM2 and the Studsvik 2202D neutron area survey instruments

  2. Plasmonic-based instrument response function for time-resolved fluorescence: toward proper lifetime analysis

    Energy Technology Data Exchange (ETDEWEB)

    Szlazak, Radoslaw; Tutaj, Krzysztof; Grudzinski, Wojciech; Gruszecki, Wieslaw I.; Luchowski, Rafal, E-mail: rafal.luchowski@umcs.pl [Maria Curie-Sklodowska University, Department of Biophysics, Institute of Physics (Poland)

    2013-06-15

    In this report, we investigated the so-called plasmonic platforms prepared to target ultra-short fluorescence and accurate instrumental response function in a time-domain spectroscopy and microscopy. The interaction of metallic nanoparticles with nearby fluorophores results in the increase of the dye fluorescence quantum yield, photostability and decrease of the lifetime parameter. The mentioned properties of platforms were applied to achieve a picosecond fluorescence lifetime (21 ps) of erythrosin B, used later as a better choice for deconvolution of fluorescence decays measured with 'color' sensitive photo-detectors. The ultra-short fluorescence standard based on combination of thin layers of silver film, silver colloidal nanoparticles (about 60 nm in diameter), and top layer of erythrosin B embedded in 0.2 % poly(vinyl) alcohol. The response functions were monitored on two photo-detectors; microchannel plate photomultiplier and single photon avalanche photodiode as a Rayleigh scattering and ultra-short fluorescence. We demonstrated that use of the plasmonic base fluorescence standard as an instrumental response function results in the absence of systematic error in lifetime measurements and analysis.

  3. LARF: Instrumental Variable Estimation of Causal Effects through Local Average Response Functions

    Directory of Open Access Journals (Sweden)

    Weihua An

    2016-07-01

    Full Text Available LARF is an R package that provides instrumental variable estimation of treatment effects when both the endogenous treatment and its instrument (i.e., the treatment inducement are binary. The method (Abadie 2003 involves two steps. First, pseudo-weights are constructed from the probability of receiving the treatment inducement. By default LARF estimates the probability by a probit regression. It also provides semiparametric power series estimation of the probability and allows users to employ other external methods to estimate the probability. Second, the pseudo-weights are used to estimate the local average response function conditional on treatment and covariates. LARF provides both least squares and maximum likelihood estimates of the conditional treatment effects.

  4. Measurement of sexual functioning after spinal cord injury: preferred instruments

    DEFF Research Database (Denmark)

    Alexander, Marcalee Sipski; Brackett, Nancy L; Bodner, Donald

    2009-01-01

    into male and female sexual function, male reproductive function, and female reproductive function. The instruments that have been used most frequently to measure these aspects of sexual function over the past 5 years were identified by expert consensus. Finally, these instruments were subjected...... to a critical review. RESULTS: The Female Sexual Function Index (FSFI), measurement of vaginal pulse amplitude (VPA), the International Index of Erectile Function (IIEF), and the measurement of ejaculatory function and semen quality were considered appropriate measures to assess sexual responses......BACKGROUND/OBJECTIVE: To determine the utility of certain instruments to assess sexuality and fertility after SCI, an expert panel identified key areas to study and evaluated available instruments. These were rated according to certain predefined criteria. METHODS: The authors divided sexual issues...

  5. THE FERMI LARGE AREA TELESCOPE ON ORBIT: EVENT CLASSIFICATION, INSTRUMENT RESPONSE FUNCTIONS, AND CALIBRATION

    Energy Technology Data Exchange (ETDEWEB)

    Ackermann, M. [Deutsches Elektronen Synchrotron DESY, D-15738 Zeuthen (Germany); Ajello, M.; Allafort, A.; Bechtol, K.; Blandford, R. D.; Bloom, E. D.; Bogart, J. R.; Borgland, A. W.; Bottacini, E. [W. W. Hansen Experimental Physics Laboratory, Kavli Institute for Particle Astrophysics and Cosmology, Department of Physics and SLAC National Accelerator Laboratory, Stanford University, Stanford, CA 94305 (United States); Albert, A. [Department of Physics, Center for Cosmology and Astro-Particle Physics, Ohio State University, Columbus, OH 43210 (United States); Atwood, W. B.; Bouvier, A. [Santa Cruz Institute for Particle Physics, Department of Physics and Department of Astronomy and Astrophysics, University of California at Santa Cruz, Santa Cruz, CA 95064 (United States); Axelsson, M. [Department of Astronomy, Stockholm University, SE-106 91 Stockholm (Sweden); Baldini, L. [Universita di Pisa and Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, I-56127 Pisa (Italy); Ballet, J. [Laboratoire AIM, CEA-IRFU/CNRS/Universite Paris Diderot, Service d' Astrophysique, CEA Saclay, F-91191 Gif sur Yvette (France); Barbiellini, G. [Istituto Nazionale di Fisica Nucleare, Sezione di Trieste, I-34127 Trieste (Italy); Bastieri, D. [Istituto Nazionale di Fisica Nucleare, Sezione di Padova, I-35131 Padova (Italy); Bellazzini, R. [Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, I-56127 Pisa (Italy); Bissaldi, E. [Institut fuer Astro- und Teilchenphysik and Institut fuer Theoretische Physik, Leopold-Franzens-Universitaet Innsbruck, A-6020 Innsbruck (Austria); Bonamente, E., E-mail: echarles@slac.stanford.edu, E-mail: luca.baldini@pi.infn.it, E-mail: rando@pd.infn.it [Istituto Nazionale di Fisica Nucleare, Sezione di Perugia, I-06123 Perugia (Italy); and others

    2012-11-15

    The Fermi Large Area Telescope (Fermi-LAT, hereafter LAT), the primary instrument on the Fermi Gamma-ray Space Telescope (Fermi) mission, is an imaging, wide field-of-view, high-energy {gamma}-ray telescope, covering the energy range from 20 MeV to more than 300 GeV. During the first years of the mission, the LAT team has gained considerable insight into the in-flight performance of the instrument. Accordingly, we have updated the analysis used to reduce LAT data for public release as well as the instrument response functions (IRFs), the description of the instrument performance provided for data analysis. In this paper, we describe the effects that motivated these updates. Furthermore, we discuss how we originally derived IRFs from Monte Carlo simulations and later corrected those IRFs for discrepancies observed between flight and simulated data. We also give details of the validations performed using flight data and quantify the residual uncertainties in the IRFs. Finally, we describe techniques the LAT team has developed to propagate those uncertainties into estimates of the systematic errors on common measurements such as fluxes and spectra of astrophysical sources.

  6. THE FERMI LARGE AREA TELESCOPE ON ORBIT: EVENT CLASSIFICATION, INSTRUMENT RESPONSE FUNCTIONS, AND CALIBRATION

    International Nuclear Information System (INIS)

    Ackermann, M.; Ajello, M.; Allafort, A.; Bechtol, K.; Blandford, R. D.; Bloom, E. D.; Bogart, J. R.; Borgland, A. W.; Bottacini, E.; Albert, A.; Atwood, W. B.; Bouvier, A.; Axelsson, M.; Baldini, L.; Ballet, J.; Barbiellini, G.; Bastieri, D.; Bellazzini, R.; Bissaldi, E.; Bonamente, E.

    2012-01-01

    The Fermi Large Area Telescope (Fermi-LAT, hereafter LAT), the primary instrument on the Fermi Gamma-ray Space Telescope (Fermi) mission, is an imaging, wide field-of-view, high-energy γ-ray telescope, covering the energy range from 20 MeV to more than 300 GeV. During the first years of the mission, the LAT team has gained considerable insight into the in-flight performance of the instrument. Accordingly, we have updated the analysis used to reduce LAT data for public release as well as the instrument response functions (IRFs), the description of the instrument performance provided for data analysis. In this paper, we describe the effects that motivated these updates. Furthermore, we discuss how we originally derived IRFs from Monte Carlo simulations and later corrected those IRFs for discrepancies observed between flight and simulated data. We also give details of the validations performed using flight data and quantify the residual uncertainties in the IRFs. Finally, we describe techniques the LAT team has developed to propagate those uncertainties into estimates of the systematic errors on common measurements such as fluxes and spectra of astrophysical sources.

  7. [Quenched fluorescein: a reference dye for instrument response function of TCSPC].

    Science.gov (United States)

    Pan, Hai-feng; Ding, Jing-xin; Liang, Rong-rong; Tao, Zhan-dong; Liu, Meng-wei; Zhang, San-jun; Xu, Jian-hua

    2014-08-01

    Measuring the instrument response function (IRF) and fitting by reconvolution algorithms are routines to improve time resolution in fluorescence lifetime measurements. Iodide ions were successfully used to quench the fluorescence of fluorescein in this study. By systematically adding saturated NaI water solution in basic fluorescein solution, the lifetimes of fluorescein were reduced from 4 ns to 24 ps. The quenched lifetime of fluorescein obtained from the analysis of Time-Correlated Single Photon Counting (TCSPC) measurement agrees well with that from femtosecond frequency up-conversion measurement. In time resolved excitation spectra measurements, the IRF should be measured at various detection wavelengths providing scattring materials are used. This study could not only reduce the complexity of IRF measurement, but also avoid the existing color effect in system. This study should have wide applications in time resolved fluorescence spectroscopy and fluorescence lifetime imaging.

  8. Social Responsibility Instruments

    Directory of Open Access Journals (Sweden)

    Katarzyna Mizera

    2008-09-01

    Full Text Available Responsible business notion is more and more present in Polish economy, however the results of the research carried out in Polish business still shows a low level of CRS idea knowledge, especially in small and medium companies. Although responsible business notion is generally known, its details, ways of preparing strategy, instruments and what is more its benefits are still narrowly spread. Many business people face the lack of knowledge and information, which on one hand make it easier to spread and deepen wrong stereotypes connected with this notion and on the other hand make business people unwilling to implement CRS in their companies. The subjects of this article are examples of instruments which are responsible for realization of social responsibility strategy.

  9. Operator Actions Within a Safety Instrumented Function

    International Nuclear Information System (INIS)

    Suttinger, L.T.

    2002-01-01

    This paper presents an overview of the factors that should be considered when crediting operator action for performing a safety function or being a part of the process of enabling a safety function. Criteria for evaluating operator action, such as required time response and operator training among others, are discussed. The paper will address these and other factors that should be considered when determining the reliability of the operator to respond and perform his/her part of the safety function. The entire safety function includes the operator and the reliability of the instrumented system that provides the alarm or indication, the final control element, and support systems. The integration of the operator performance with the hardware safety availability, including the effects of the supporting systems is discussed. The analysis of these factors will provide the justification for the amount of risk reduction or safety integrity level that can be credited for the Safety Instrumented Function (SIF), including operator action

  10. Aversive pavlovian responses affect human instrumental motor performance.

    Science.gov (United States)

    Rigoli, Francesco; Pavone, Enea Francesco; Pezzulo, Giovanni

    2012-01-01

    IN NEUROSCIENCE AND PSYCHOLOGY, AN INFLUENTIAL PERSPECTIVE DISTINGUISHES BETWEEN TWO KINDS OF BEHAVIORAL CONTROL: instrumental (habitual and goal-directed) and Pavlovian. Understanding the instrumental-Pavlovian interaction is fundamental for the comprehension of decision-making. Animal studies (as those using the negative auto-maintenance paradigm), have demonstrated that Pavlovian mechanisms can have maladaptive effects on instrumental performance. However, evidence for a similar effect in humans is scarce. In addition, the mechanisms modulating the impact of Pavlovian responses on instrumental performance are largely unknown, both in human and non-human animals. The present paper describes a behavioral experiment investigating the effects of Pavlovian conditioned responses on performance in humans, focusing on the aversive domain. Results showed that Pavlovian responses influenced human performance, and, similar to animal studies, could have maladaptive effects. In particular, Pavlovian responses either impaired or increased performance depending on modulator variables such as threat distance, task controllability, punishment history, amount of training, and explicit punishment expectancy. Overall, these findings help elucidating the computational mechanisms underlying the instrumental-Pavlovian interaction, which might be at the base of apparently irrational phenomena in economics, social behavior, and psychopathology.

  11. Aversive Pavlovian responses affect human instrumental motor performance

    Directory of Open Access Journals (Sweden)

    Francesco eRigoli

    2012-10-01

    Full Text Available In neuroscience and psychology, an influential perspective distinguishes between two kinds of behavioural control: instrumental (habitual and goal-directed and Pavlovian. Understanding the instrumental-Pavlovian interaction is fundamental for the comprehension of decision-making. Animal studies (as those using the negative auto-maintenance paradigm, have demonstrated that Pavlovian mechanisms can have maladaptive effects on instrumental performance. However, evidence for a similar effect in humans is scarce. In addition, the mechanisms modulating the impact of Pavlovian responses on instrumental performance are largely unknown, both in human and non-human animals. The present paper describes a behavioural experiment investigating the effects of Pavlovian conditioned responses on performance in humans, focusing on the aversive domain. Results showed that Pavlovian responses influenced human performance, and, similar to animal studies, could have maladaptive effects. In particular, Pavlovian responses either impaired or increased performance depending on modulator variables such as threat distance, task controllability, punishment history, amount of training, and explicit punishment expectancy. Overall, these findings help elucidating the computational mechanisms underlying the instrumental-Pavlovian interaction, which might be at the base of apparently irrational phenomena in economics, social behaviour, and psychopathology.

  12. Use of an improved radiation amplification factor to estimate the effect of total ozone changes on action spectrum weighted irradiances and an instrument response function

    Science.gov (United States)

    Herman, Jay R.

    2010-12-01

    Multiple scattering radiative transfer results are used to calculate action spectrum weighted irradiances and fractional irradiance changes in terms of a power law in ozone Ω, U(Ω/200)-RAF, where the new radiation amplification factor (RAF) is just a function of solar zenith angle. Including Rayleigh scattering caused small differences in the estimated 30 year changes in action spectrum-weighted irradiances compared to estimates that neglect multiple scattering. The radiative transfer results are applied to several action spectra and to an instrument response function corresponding to the Solar Light 501 meter. The effect of changing ozone on two plant damage action spectra are shown for plants with high sensitivity to UVB (280-315 nm) and those with lower sensitivity, showing that the probability for plant damage for the latter has increased since 1979, especially at middle to high latitudes in the Southern Hemisphere. Similarly, there has been an increase in rates of erythemal skin damage and pre-vitamin D3 production corresponding to measured ozone decreases. An example conversion function is derived to obtain erythemal irradiances and the UV index from measurements with the Solar Light 501 instrument response function. An analytic expressions is given to convert changes in erythemal irradiances to changes in CIE vitamin-D action spectrum weighted irradiances.

  13. Development of a computer-adaptive physical function instrument for Social Security Administration disability determination.

    Science.gov (United States)

    Ni, Pengsheng; McDonough, Christine M; Jette, Alan M; Bogusz, Kara; Marfeo, Elizabeth E; Rasch, Elizabeth K; Brandt, Diane E; Meterko, Mark; Haley, Stephen M; Chan, Leighton

    2013-09-01

    To develop and test an instrument to assess physical function for Social Security Administration (SSA) disability programs, the SSA-Physical Function (SSA-PF) instrument. Item response theory (IRT) analyses were used to (1) create a calibrated item bank for each of the factors identified in prior factor analyses, (2) assess the fit of the items within each scale, (3) develop separate computer-adaptive testing (CAT) instruments for each scale, and (4) conduct initial psychometric testing. Cross-sectional data collection; IRT analyses; CAT simulation. Telephone and Internet survey. Two samples: SSA claimants (n=1017) and adults from the U.S. general population (n=999). None. Model fit statistics, correlation, and reliability coefficients. IRT analyses resulted in 5 unidimensional SSA-PF scales: Changing & Maintaining Body Position, Whole Body Mobility, Upper Body Function, Upper Extremity Fine Motor, and Wheelchair Mobility for a total of 102 items. High CAT accuracy was demonstrated by strong correlations between simulated CAT scores and those from the full item banks. On comparing the simulated CATs with the full item banks, very little loss of reliability or precision was noted, except at the lower and upper ranges of each scale. No difference in response patterns by age or sex was noted. The distributions of claimant scores were shifted to the lower end of each scale compared with those of a sample of U.S. adults. The SSA-PF instrument contributes important new methodology for measuring the physical function of adults applying to the SSA disability programs. Initial evaluation revealed that the SSA-PF instrument achieved considerable breadth of coverage in each content domain and demonstrated noteworthy psychometric properties. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  14. Ultrafast electron microscopy: Instrument response from the single-electron to high bunch-charge regimes

    Science.gov (United States)

    Plemmons, Dayne A.; Flannigan, David J.

    2017-09-01

    We determine the instrument response of an ultrafast electron microscope equipped with a conventional thermionic electron gun and absent modifications beyond the optical ports. Using flat, graphite-encircled LaB6 cathodes, we image space-charge effects as a function of photoelectron-packet population and find that an applied Wehnelt bias has a negligible effect on the threshold levels (>103 electrons per pulse) but does appear to suppress blurring at the upper limits (∼105 electrons). Using plasma lensing, we determine the instrument-response time for 700-fs laser pulses and find that single-electron packets are laser limited (1 ps), while broadening occurs well below the space-charge limit.

  15. Systematization of Instruments of Social and Economic Responsibility of Enterprises: Theoretical Aspect

    Directory of Open Access Journals (Sweden)

    Dielini Maryna M.

    2016-11-01

    Full Text Available The aim of the article is systematization of instruments for implementation of social and economic responsibility of enterprises in Ukraine and theoretical consideration of the presented instruments. The article studies basic views on instruments of social responsibility of business. It is determined which of them are more traditional, and which ones are the latest, that is up to date. Thus, the traditional ones include: philanthropy, charity, sponsorship, volunteering, patronship, monetary grants, equivalent financing. Based on the understanding of the nature of social and economic responsibility of business proposed by the author, to its instruments there can be attributed all traditional instruments, except for volunteering that does not imply obtaining funds for its activities and has only a social effect. There studied modern instruments of business social responsibility, such as social investments, socially responsible investments, social marketing, charity marketing, social programs, social entrepreneurship, social reporting and social expertise, fundraising, socially responsible approaches to doing business and supply chain management. All of them can be regarded as instruments of social and economic responsibility of business.

  16. The Formation of Instruments of Management of Industrial Enterprises According to the Theoretical and Functional Approaches

    Directory of Open Access Journals (Sweden)

    Raiko Diana V.

    2018-03-01

    Full Text Available The article is aimed at the substantiation based on the analysis of the company theories of the basic theoretical provisions on the formation of industrial enterprise management instruments. The article determines that the subject of research in theories is enterprise, the object is the process of management of potential according to the forms of business organization and technology of partnership relations, the goal is high financial results, stabilization of the activity, and social responsibility. The publication carries out an analysis of enterprise theories on the determining of its essence as a socio-economic system in the following directions: technical preparation of production, economic theory and law, theory of systems, marketing-management. As a result of the research, the general set of functions has been identified – the socio-economic functions of enterprise by groups: information-legal, production, marketing-management, social responsibility. When building management instruments, it is suggested to take into consideration the direct and inverse relationships of enterprise at all levels of management – micro, meso and macro. On this ground, the authors have developed provisions on formation of instruments of management of industrial enterprises according to two approaches – theoretical and functional.

  17. Development of measurement standards for verifying functional performance of surface texture measuring instruments

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, A [Life and Industrial Product Development Department Olympus Corporation, 2951 Ishikawa-machi, Hachiouji-shi, Tokyo (Japan); Suzuki, H [Industrial Marketing and Planning Department Olympus Corporation, Shinjyuku Monolith, 3-1 Nishi-Shinjyuku 2-chome, Tokyo (Japan); Yanagi, K, E-mail: a_fujii@ot.olympus.co.jp [Department of Mechanical Engineering, Nagaoka University of Technology, 1603-1 Kamitomioka-machi, Nagaoka-shi, Niigata (Japan)

    2011-08-19

    A new measurement standard is proposed for verifying overall functional performance of surface texture measuring instruments. Its surface is composed of sinusoidal surface waveforms of chirp signals along horizontal cross sections of the material measure. One of the notable features is that the amplitude of each cycle in the chirp signal form is geometrically modulated so that the maximum slope is kept constant. The maximum slope of the chirp-like signal is gradually decreased according to movement in the lateral direction. We fabricated the measurement standard by FIB processing, and it was calibrated by AFM. We tried to evaluate the functional performance of Laser Scanning Microscope by this standard in terms of amplitude response with varying slope angles. As a result, it was concluded that the proposed standard can easily evaluate the performance of surface texture measuring instruments.

  18. Comparing the responsiveness of functional outcome assessment measures for trauma registries.

    Science.gov (United States)

    Williamson, Owen D; Gabbe, Belinda J; Sutherland, Ann M; Wolfe, Rory; Forbes, Andrew B; Cameron, Peter A

    2011-07-01

    Measuring long-term disability and functional outcomes after major trauma is not standardized across trauma registries. An ideal measure would be responsive to change but not have significant ceiling effects. The aim of this study was to compare the responsiveness of the Glasgow Outcome Scale (GOS), GOS-Extended (GOSE), Functional Independence Measure (FIM), and modified FIM in major trauma patients, with and without significant head injuries. Patients admitted to two adult Level I trauma centers in Victoria, Australia, who survived to discharge from hospital, were aged 15 years to 80 years with a blunt mechanism of injury, and had an estimated Injury Severity Score >15 on admission, were recruited for this prospective study. The instruments were administered at baseline (hospital discharge) and by telephone interview 6 months after injury. Measures of responsiveness, including effect sizes, were calculated. Bootstrapping techniques, and floor and ceiling effects, were used to compare the measures. Two hundred forty-three patients participated, of which 234 patients (96%) completed the study. The GOSE and GOS were the most responsive instruments in this major trauma population with effect sizes of 5.3 and 4.4, respectively. The GOSE had the lowest ceiling effect (17%). The GOSE was the instrument with greatest responsiveness and the lowest ceiling effect in a major trauma population with and without significant head injuries and is recommended for use by trauma registries for monitoring functional outcomes and benchmarking care. The results of this study do not support the use of the modified FIM for this purpose.

  19. Seismic response analysis of an instrumented building structure

    Science.gov (United States)

    Li, H.-J.; Zhu, S.-Y.; Celebi, M.

    2003-01-01

    The Sheraton - Universal hotel, an instrumented building lying in North Hollywood, USA is selected for case study in this paper. The finite element method is used to produce a linear time - invariant structural model, and the SAP2000 program is employed for the time history analysis of the instrumented structure under the base excitation of strong motions recorded in the basement during the Northridge, California earthquake of 17 January 1994. The calculated structural responses are compared with the recorded data in both time domain and frequency domain, and the effects of structural parameters evaluation and indeterminate factors are discussed. Some features of structural response, such as the reason why the peak responses of acceleration in the ninth floor are larger than those in the sixteenth floor, are also explained.

  20. Transient response of level instruments in a research reactor

    International Nuclear Information System (INIS)

    Cheng, Lap Y.

    1989-01-01

    A numerical model has been developed to simulate the dynamics of water level instruments in a research nuclear reactor. A bubble device, with helium gas as the working fluid, is used to monitor liquid level by sensing the static head pressure due to the height of liquid in the reactor vessel. A finite-difference model is constructed to study the transient response of the water level instruments to pressure perturbations. The field equations which describe the hydraulics of the helium gas in the bubbler device are arranged in the form of a tridiagonal matrix and the field variables are solved at each time step by the Thomas algorithm. Simulation results indicate that the dynamic response of the helium gas depends mainly on the volume and the inertia of the gas in the level instrument tubings. The anomalies in the simulated level indication are attributed to the inherent lag in the level instrument due to the hydraulics of the system. 1 ref., 5 figs

  1. Minimal Function Graphs are not Instrumented

    DEFF Research Database (Denmark)

    Mycroft, Alan; Rosendahl, Mads

    1992-01-01

    The minimal function graph semantics of Jones and Mycroft is a standard denotational semantics modified to include only `reachable' parts of a program. We show that it may be expressed directly in terms of the standard semantics without the need for instrumentation at the expression level and......, in doing so, bring out a connection with strictness. This also makes it possible to prove a stronger theorem of correctness for the minimal function graph semantics....

  2. Swift Burst Alert Telescope (BAT) Instrument Response

    International Nuclear Information System (INIS)

    Parsons, A.; Barthelmy, S.; Cummings, J.; Gehrels, N.; Hullinger, D.; Krimm, H.; Markwardt, C.; Tueller, J.; Fenimore, E.; Palmer, D.; Sato, G.; Takahashi, T.; Nakazawa, K.; Okada, Y.; Takahashi, H.; Suzuki, M.; Tashiro, M.

    2004-01-01

    The Burst Alert Telescope (BAT), a large coded aperture instrument with a wide field-of-view (FOV), provides the gamma-ray burst triggers and locations for the Swift Gamma-Ray Burst Explorer. In addition to providing this imaging information, BAT will perform a 15 keV - 150 keV all-sky hard x-ray survey based on the serendipitous pointings resulting from the study of gamma-ray bursts, and will also monitor the sky for transient hard x-ray sources. For BAT to provide spectral and photometric information for the gamma-ray bursts, the transient sources and the all-sky survey, the BAT instrument response must be determined to an increasingly greater accuracy. This paper describes the spectral models and the ground calibration experiments used to determine the BAT response to an accuracy suitable for gamma-ray burst studies

  3. Tank SY-101 void fraction instrument functional design criteria

    International Nuclear Information System (INIS)

    McWethy, L.M.

    1994-01-01

    This document presents the functional design criteria for design, analysis, fabrication, testing, and installation of a void fraction instrument for Tank SY-101. This instrument will measure the void fraction in the waste in Tank SY-101 at various elevations

  4. How discriminating are discriminative instruments?

    Science.gov (United States)

    Hankins, Matthew

    2008-05-27

    The McMaster framework introduced by Kirshner & Guyatt is the dominant paradigm for the development of measures of health status and health-related quality of life (HRQL). The framework defines the functions of such instruments as evaluative, predictive or discriminative. Evaluative instruments are required to be sensitive to change (responsiveness), but there is no corresponding index of the degree to which discriminative instruments are sensitive to cross-sectional differences. This paper argues that indices of validity and reliability are not sufficient to demonstrate that a discriminative instrument performs its function of discriminating between individuals, and that the McMaster framework would be augmented by the addition of a separate index of discrimination. The coefficient proposed by Ferguson (Delta) is easily adapted to HRQL instruments and is a direct, non-parametric index of the degree to which an instrument distinguishes between individuals. While Delta should prove useful in the development and evaluation of discriminative instruments, further research is required to elucidate the relationship between the measurement properties of discrimination, reliability and responsiveness.

  5. How discriminating are discriminative instruments?

    Directory of Open Access Journals (Sweden)

    Hankins Matthew

    2008-05-01

    Full Text Available Abstract The McMaster framework introduced by Kirshner & Guyatt is the dominant paradigm for the development of measures of health status and health-related quality of life (HRQL. The framework defines the functions of such instruments as evaluative, predictive or discriminative. Evaluative instruments are required to be sensitive to change (responsiveness, but there is no corresponding index of the degree to which discriminative instruments are sensitive to cross-sectional differences. This paper argues that indices of validity and reliability are not sufficient to demonstrate that a discriminative instrument performs its function of discriminating between individuals, and that the McMaster framework would be augmented by the addition of a separate index of discrimination. The coefficient proposed by Ferguson (Delta is easily adapted to HRQL instruments and is a direct, non-parametric index of the degree to which an instrument distinguishes between individuals. While Delta should prove useful in the development and evaluation of discriminative instruments, further research is required to elucidate the relationship between the measurement properties of discrimination, reliability and responsiveness.

  6. Evaluation of the measurement properties of self-reported health-related work-functioning instruments among workers with common mental disorders.

    Science.gov (United States)

    Abma, Femke I; van der Klink, Jac J L; Terwee, Caroline B; Amick, Benjamin C; Bültmann, Ute

    2012-01-01

    During the past decade, common mental disorders (CMD) have emerged as a major public and occupational health problem in many countries. Several instruments have been developed to measure the influence of health on functioning at work. To select appropriate instruments for use in occupational health practice and research, the measurement properties (eg, reliability, validity, responsiveness) must be evaluated. The objective of this study is to appraise critically and compare the measurement properties of self-reported health-related work-functioning instruments among workers with CMD. A systematic review was performed searching three electronic databases. Papers were included that: (i) mainly focused on the development and/or evaluation of the measurement properties of a self-reported health-related work-functioning instrument; (ii) were conducted in a CMD population; and (iii) were fulltext original papers. Quality appraisal was performed using the consensus-based standards for the selection of health status measurement instruments (COSMIN) checklist. Five papers evaluating measurement properties of five self-reported health-related work-functioning instruments in CMD populations were included. There is little evidence available for the measurement properties of the identified instruments in this population, mainly due to low methodological quality of the included studies. The available evidence on measurement properties is based on studies of poor-to-fair methodological quality. Information on a number of measurement properties, such as measurement error, content validity, and cross-cultural validity is still lacking. Therefore, no evidence-based decisions and recommendations can be made for the use of health-related work functioning instruments. Studies of high methodological quality are needed to properly assess the existing instruments' measurement properties.

  7. Calibration of UV instruments and limitations on accuracy

    International Nuclear Information System (INIS)

    Clare, J.F.; Hamlin, J.D.

    1993-01-01

    Instruments measuring UV radiation may be classified as either spectrometers or broadband monitors; whilst the former determine irradiance as a function of wavelength the latter measure a summation of spectral irradiance weighted by some instrument response function which may be designed to approximate a desired action spectrum. For both classes a proper calibration requires the determination of the instrument's absolute spectral responsivity across the relevant wave-band together with an adequate determination of the wavelengths involved. (author). 7 refs

  8. Instrument response during overpower transients at TREAT

    International Nuclear Information System (INIS)

    Meek, C.C.; Bauer, T.H.; Hill, D.J.; Froehle, P.H.; Klickman, A.E.; Tylka, J.P.; Doerner, R.C.; Wright, A.E.

    1982-01-01

    A program to empirically analyze data residuals or noise to determine instrument response that occurs during in-pile transient tests is out-lined. As an example, thermocouple response in the Mark III loop during a severe overpower transient in TREAT is studied both in frequency space and in real-time. Time intervals studied included both constant power and burst portions of the power transient. Thermocouple time constants were computed. Benefits and limitations of the method are discussed

  9. 241-SY-101 multi-functional instrument tree acceptance for beneficial use (ABU)

    International Nuclear Information System (INIS)

    Erhart, M.F.

    1995-01-01

    This document formally demonstrates that the ABU process for the 241-SY-101 risers 17B and 17C Multi-functional Instrument Trees (MIT's) has been properly completed in accordance with the approved ABU checklists. For each item required on the ABU Checklist, a bibliography of the documentation prepared and released to satisfy the requirements is provided. Release of this documentation signifies that the tank farm Operations, Engineering, and Maintenance organizations have accepted responsibility for the MIT'S in 241-SY-101 Risers 17B and 17C

  10. Impact of instrumental response on observed ozonesonde profiles: First-order estimates and implications for measures of variability

    Science.gov (United States)

    Clifton, G. T.; Merrill, J. T.; Johnson, B. J.; Oltmans, S. J.

    2009-12-01

    Ozonesondes provide information on the ozone distribution up to the middle stratosphere. Ozone profiles often feature layers, with vertically discrete maxima and minima in the mixing ratio. Layers are especially common in the UT/LS regions and originate from wave breaking, shearing and other transport processes. ECC sondes, however, have a moderate response time to significant changes in ozone. A sonde can ascend over 350 meters before it responds fully to a step change in ozone. This results in an overestimate of the altitude assigned to layers and an underestimate of the underlying variability in the amount of ozone. An estimate of the response time is made for each instrument during the preparation for flight, but the profile data are typically not processed to account for the response. Here we present a method of categorizing the response time of ECC instruments and an analysis of a low-pass filter approximation to the effects on profile data. Exponential functions were fit to the step-up and step-down responses using laboratory data. The resulting response time estimates were consistent with results from standard procedures, with the up-step response time exceeding the down-step value somewhat. A single-pole Butterworth filter that approximates the instrumental effect was used with synthetic layered profiles to make first-order estimates of the impact of the finite response time. Using a layer analysis program previously applied to observed profiles we find that instrumental effects can attenuate ozone variability by 20-45% in individual layers, but that the vertical offset in layer altitudes is moderate, up to about 150 meters. We will present results obtained using this approach, coupled with data on the distribution of layer characteristics found using the layer analysis procedure on profiles from Narragansett, Rhode Island and other US sites to quantify the impact on overall variability estimates given ambient distributions of layer occurrence, thickness

  11. Instrument Response Modeling and Simulation for the GLAST Burst Monitor

    International Nuclear Information System (INIS)

    Kippen, R. M.; Hoover, A. S.; Wallace, M. S.; Pendleton, G. N.; Meegan, C. A.; Fishman, G. J.; Wilson-Hodge, C. A.; Kouveliotou, C.; Lichti, G. G.; Kienlin, A. von; Steinle, H.; Diehl, R.; Greiner, J.; Preece, R. D.; Connaughton, V.; Briggs, M. S.; Paciesas, W. S.; Bhat, P. N.

    2007-01-01

    The GLAST Burst Monitor (GBM) is designed to provide wide field of view observations of gamma-ray bursts and other fast transient sources in the energy range 10 keV to 30 MeV. The GBM is composed of several unshielded and uncollimated scintillation detectors (twelve NaI and two BGO) that are widely dispersed about the GLAST spacecraft. As a result, reconstructing source locations, energy spectra, and temporal properties from GBM data requires detailed knowledge of the detectors' response to both direct radiation as well as that scattered from the spacecraft and Earth's atmosphere. This full GBM instrument response will be captured in the form of a response function database that is derived from computer modeling and simulation. The simulation system is based on the GEANT4 Monte Carlo radiation transport simulation toolset, and is being extensively validated against calibrated experimental GBM data. We discuss the architecture of the GBM simulation and modeling system and describe how its products will be used for analysis of observed GBM data. Companion papers describe the status of validating the system

  12. Experimental study of the response functions of direct-reading instruments measuring surface-area concentration of airborne nanostructured particles

    International Nuclear Information System (INIS)

    Bau, Sebastien; Witschger, Olivier; Gensdarmes, Francois; Thomas, Dominique

    2009-01-01

    An increasing number of experimental and theoretical studies focus on airborne nanoparticles (NP) in relation with many aspects of risk assessment to move forward our understanding of the hazards, the actual exposures in the workplace, and the limits of engineering controls and personal protective equipment with regard to NP. As a consequence, generating airborne NP with controlled properties constitutes an important challenge. In parallel, toxicological studies have been carried out, and most of them support the concept that surface-area could be a relevant metric for characterizing exposure to airborne NP. To provide NP surface-area concentration measurements, some direct-reading instruments have been designed, based on attachment rate of unipolar ions to NP by diffusion. However, very few information is available concerning the performances of these instruments and the parameters that could affect their responses. In this context, our work aims at characterizing the actual available instruments providing airborne NP surface-area concentration. The instruments (a- LQ1-DC, Matter Engineering; b-AeroTrak x2122 9000, TSI; c- NSAM, TSI model 3550;) are thought to be relevant for further workplace exposure characterization and monitoring. To achieve our work, an experimental facility (named CAIMAN) was specially designed, built and characterized.

  13. Experimental study of the response functions of direct-reading instruments measuring surface-area concentration of airborne nanostructured particles

    Energy Technology Data Exchange (ETDEWEB)

    Bau, Sebastien; Witschger, Olivier [Institut National de Recherche et de Securite, INRS, Laboratoire de Metrologie des Aerosols, Rue du Morvan, CS 60027, 54519 Vandoeuvre Cedex (France); Gensdarmes, Francois [Institut de Radioprotection et de Surete Nucleaire, IRSN, Laboratoire de Physique et de Metrologie des Aerosols, BP 68, 91192 Gif-sur-Yvette Cedex (France); Thomas, Dominique [Laboratoire des Sciences du Genie Chimique, LSGC/CNRS, Nancy Universite, BP 2041, 54001 Nancy Cedex (France)], E-mail: sebastien.bau@inrs.fr

    2009-05-01

    An increasing number of experimental and theoretical studies focus on airborne nanoparticles (NP) in relation with many aspects of risk assessment to move forward our understanding of the hazards, the actual exposures in the workplace, and the limits of engineering controls and personal protective equipment with regard to NP. As a consequence, generating airborne NP with controlled properties constitutes an important challenge. In parallel, toxicological studies have been carried out, and most of them support the concept that surface-area could be a relevant metric for characterizing exposure to airborne NP. To provide NP surface-area concentration measurements, some direct-reading instruments have been designed, based on attachment rate of unipolar ions to NP by diffusion. However, very few information is available concerning the performances of these instruments and the parameters that could affect their responses. In this context, our work aims at characterizing the actual available instruments providing airborne NP surface-area concentration. The instruments (a- LQ1-DC, Matter Engineering; b-AeroTrak{sup x2122} 9000, TSI; c- NSAM, TSI model 3550;) are thought to be relevant for further workplace exposure characterization and monitoring. To achieve our work, an experimental facility (named CAIMAN) was specially designed, built and characterized.

  14. ADMINISTRATIVE INSTRUMENTS IN IMPLEMENTING FUNCTIONAL STRATEGIES COMPETITIVENESS MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Iryna Stankovska

    2017-03-01

    Full Text Available The article explores the use of  аdministrative instruments in implementing functional strategies competitiveness management. Due to providing strategic financial management competitiveness the use of administrative levers of control in the formulation and implementation of financial strategies were investigated. System of financial policies forming by individual policies of  general financial strategy, which is an administrative levers of influence on implementation strategies, was proposed. Structure strategic alternatives of financial and investment strategy implementation based on the decomposition and decision tree was formed. To select strategic alternatives, to identify strategic gaps and evaluate deviations from specified target markers in the implementation of financial policies using GAP-analysis that is a tool of management analysis was proposed. Key words: functional strategy, financial strategy, competitiveness management, financial policy, administrative instruments, GAP-analysis.

  15. Financial and testamentary capacity evaluations: procedures and assessment instruments underneath a functional approach.

    Science.gov (United States)

    Sousa, Liliana B; Simões, Mário R; Firmino, Horácio; Peisah, Carmelle

    2014-02-01

    Mental health professionals are frequently involved in mental capacity determinations. However, there is a lack of specific measures and well-defined procedures for these evaluations. The main purpose of this paper is to provide a review of financial and testamentary capacity evaluation procedures, including not only the traditional neuropsychological and functional assessment but also the more recently developed forensic assessment instruments (FAIs), which have been developed to provide a specialized answer to legal systems regarding civil competencies. Here the main guidelines, papers, and other references are reviewed in order to achieve a complete and comprehensive selection of instruments used in the assessment of financial and testamentary capacity. Although some specific measures for financial abilities have been developed recently, the same is not true for testamentary capacity. Here are presented several instruments or methodologies for assessing financial and testamentary capacity, including neuropsychological assessment, functional assessment scales, performance based functional assessment instruments, and specific FAIs. FAIs are the only specific instruments intended to provide a specific and direct answer to the assessment of financial capacity based on legal systems. Considering the need to move from a diagnostic to a functional approach in financial and testamentary capacity evaluations, it is essential to consider both general functional examination as well as cognitive functioning.

  16. Learning to inhibit the response during instrumental (operant) extinction.

    Science.gov (United States)

    Bouton, Mark E; Trask, Sydney; Carranza-Jasso, Rodrigo

    2016-07-01

    Five experiments tested implications of the idea that instrumental (operant) extinction involves learning to inhibit the learned response. All experiments used a discriminated operant procedure in which rats were reinforced for lever pressing or chain pulling in the presence of a discriminative stimulus (S), but not in its absence. In Experiment 1, extinction of the response (R) in the presence of S weakened responding in S, but equivalent nonreinforced exposure to S (without the opportunity to make R) did not. Experiment 2 replicated that result and found that extinction of R had no effect on a different R that had also been reinforced in the stimulus. In Experiments 3 and 4, rats first learned to perform several different stimulus and response combinations (S1R1, S2R1, S3R2, and S4R2). Extinction of a response in one stimulus (i.e., S1R1) transferred and weakened the same response, but not a different response, when it was tested in another stimulus (i.e., S2R1 but not S3R2). In Experiment 5, extinction still transferred between S1 and S2 when the stimuli set the occasion for R's association with different types of food pellets. The results confirm the importance of response inhibition in instrumental extinction: Nonreinforcement of the response in S causes the most effective suppression of responding, and response suppression is specific to the response but transfers and influences performance of the same response when it is occasioned by other stimuli. Theoretical and practical implications are discussed. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  17. Learning to inhibit the response during instrumental (operant) extinction

    Science.gov (United States)

    Bouton, Mark E.; Trask, Sydney; Carranza-Jasso, Rodrigo

    2016-01-01

    Five experiments tested implications of the idea that instrumental (operant) extinction involves learning to inhibit the learned response. All experiments used a discriminated operant procedure in which rats were reinforced for lever pressing or chain pulling in the presence of a discriminative stimulus (S), but not in its absence. In Experiment 1, extinction of the response (R) in the presence of S weakened responding in S, but equivalent nonreinforced exposure to S (without the opportunity to make R) did not. Experiment 2 replicated that result and found that extinction of R had no effect on a different R that had also been reinforced in the stimulus. In Experiments 3 and 4, rats first learned to perform several different stimulus and response combinations (S1R1, S2R1, S3R2, and S4R2). Extinction of a response in one stimulus (i.e., S1R1) transferred and weakened the same response, but not a different response, when it was tested in another stimulus (i.e., S2R1 but not S3R2). In Experiment 5, extinction still transferred between S1 and S2 when the stimuli set the occasion for R's association with different types of food pellets. The results confirm the importance of response inhibition in instrumental extinction: Nonreinforcement of the response in S causes the most effective suppression of responding, and response suppression is specific to the response but transfers and influences performance of the same response when it is occasioned by other stimuli. Theoretical and practical implications are discussed. PMID:27379715

  18. [Instrument to measure adherence in hypertensive patients: contribution of Item Response Theory].

    Science.gov (United States)

    Rodrigues, Malvina Thaís Pacheco; Moreira, Thereza Maria Magalhaes; Vasconcelos, Alexandre Meira de; Andrade, Dalton Francisco de; Silva, Daniele Braz da; Barbetta, Pedro Alberto

    2013-06-01

    To analyze, by means of "Item Response Theory", an instrument to measure adherence to t treatment for hypertension. Analytical study with 406 hypertensive patients with associated complications seen in primary care in Fortaleza, CE, Northeastern Brazil, 2011 using "Item Response Theory". The stages were: dimensionality test, calibrating the items, processing data and creating a scale, analyzed using the gradual response model. A study of the dimensionality of the instrument was conducted by analyzing the polychoric correlation matrix and factor analysis of complete information. Multilog software was used to calibrate items and estimate the scores. Items relating to drug therapy are the most directly related to adherence while those relating to drug-free therapy need to be reworked because they have less psychometric information and low discrimination. The independence of items, the small number of levels in the scale and low explained variance in the adjustment of the models show the main weaknesses of the instrument analyzed. The "Item Response Theory" proved to be a relevant analysis technique because it evaluated respondents for adherence to treatment for hypertension, the level of difficulty of the items and their ability to discriminate between individuals with different levels of adherence, which generates a greater amount of information. The instrument analyzed is limited in measuring adherence to hypertension treatment, by analyzing the "Item Response Theory" of the item, and needs adjustment. The proper formulation of the items is important in order to accurately measure the desired latent trait.

  19. Computer-Aided Instruction in Automated Instrumentation.

    Science.gov (United States)

    Stephenson, David T.

    1986-01-01

    Discusses functions of automated instrumentation systems, i.e., systems which combine electrical measuring instruments and a controlling computer to measure responses of a unit under test. The computer-assisted tutorial then described is programmed for use on such a system--a modern microwave spectrum analyzer--to introduce engineering students to…

  20. Instrumentation Audit: Responsibility Crisis and a Challenge to Organization

    International Nuclear Information System (INIS)

    Norpaiza Mohd Hasan; Siti Radiah Mohd Kamarudin; Hairul Nizam Idris; Zaharuddin Ahmad

    2011-01-01

    Scientific equipment today is one of the things that is very important in modern research and development. Research agencies usually have a lot of sophisticated scientific equipment and expensive, Nuclear Malaysia is one the example. When an organization has a lot of expensive equipment, so sometimes there are things that are overlooked that contribute to the damage of the equipment or the use of minimal equipment compared to the price. The audit committee was established to examine the equipment. This auditing purposely is to know the current status of condition, use and frequency of use of scientific equipment in Nuclear Malaysia. Committee is composed of a number of research officers and senior technical assistant. Committee is divided into 8 teams audit consists of 2 officers and a technician for each. Audit just only done on equipment purchased through quotations or tenders (for example more than RM50,000 ). Audit process performed from July 2010 to May 2011. A total of 62 scientific instruments were successfully audited. Results showed that 1.6 % damaged tools full 6.5 % while the device is being repaired by 90.3 % well-functioning tool. Most of the scientific equipment are damaged due to the turmoil that is the responsibility of lack of regular maintenance. Awareness of the importance of regular maintenance and use of log books among officials responsible still at low. Willingness to change from different attitude to be more responsible for the scientific equipment poses a challenge to the organization. (author)

  1. Instrument validation project

    International Nuclear Information System (INIS)

    Reynolds, B.A.; Daymo, E.A.; Geeting, J.G.H.; Zhang, J.

    1996-06-01

    Westinghouse Hanford Company Project W-211 is responsible for providing the system capabilities to remove radioactive waste from ten double-shell tanks used to store radioactive wastes on the Hanford Site in Richland, Washington. The project is also responsible for measuring tank waste slurry properties prior to injection into pipeline systems, including the Replacement of Cross-Site Transfer System. This report summarizes studies of the appropriateness of the instrumentation specified for use in Project W-211. The instruments were evaluated in a test loop with simulated slurries that covered the range of properties specified in the functional design criteria. The results of the study indicate that the compact nature of the baseline Project W-211 loop does not result in reduced instrumental accuracy resulting from poor flow profile development. Of the baseline instrumentation, the Micromotion densimeter, the Moore Industries thermocouple, the Fischer and Porter magnetic flow meter, and the Red Valve Pressure transducer meet the desired instrumental accuracy. An alternate magnetic flow meter (Yokagawa) gave nearly identical results as the baseline fischer and Porter. The Micromotion flow meter did not meet the desired instrument accuracy but could potentially be calibrated so that it would meet the criteria. The Nametre on-line viscometer did not meet the desired instrumental accuracy and is not recommended as a quantitative instrument although it does provide qualitative information. The recommended minimum set of instrumentation necessary to ensure the slurry meets the Project W-058 acceptance criteria is the Micromotion mass flow meter and delta pressure cells

  2. Standard reference for instrument response function in fluorescence lifetime measurements in visible and near infrared

    International Nuclear Information System (INIS)

    Chib, Rahul; Shah, Sunil; Gryczynski, Zygmunt; Fudala, Rafal; Borejdo, Julian; Gryczynski, Ignacy; Zelent, Bogumil; Corradini, Maria G; Ludescher, Richard D

    2016-01-01

    Allura red (AR) fluorophore, a common dye in the food industry, displays a broad emission spectrum in water (visible-to-near infrared region of the electromagnetic spectrum) and has a remarkably short fluorescence lifetime of about 10 ps. This short lifetime does not depend on the emission (observation) wavelength. We examined time responses of AR fluorescence across emission wavelengths from 550 nm to 750 nm and found that it is an ideal candidate for impulse response functions in fluorescence lifetime measurements. (technical note)

  3. Instrument care: everyone's responsibility

    Directory of Open Access Journals (Sweden)

    Renée du Toit

    2011-12-01

    Full Text Available Everyone working in an ophthalmic operating theatre must be competent in the care, handling, storage, and maintenance of instruments. This will help to improve surgical outcomes, maintain an economic and affordable service for patients, and provide a safe environment for the wellbeing of patients and staff.Including instrument care in theatre courses and in-service training is one way of ensuring staff competence.

  4. Real-time instrument-failure detection in the LOFT pressurizer using functional redundancy

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1982-07-01

    The functional redundancy approach to detecting instrument failures in a pressurized water reactor (PWR) pressurizer is described and evaluated. This real-time method uses a bank of Kalman filters (one for each instrument) to generate optimal estimates of the pressurizer state. By performing consistency checks between the output of each filter, failed instruments can be identified. Simulation results and actual pressurizer data are used to demonstrate the capabilities of the technique

  5. Use of the ORACLE DBMS in determining the response of complex scientific instrumentation

    International Nuclear Information System (INIS)

    Auerbach, J.M.; DeMartini, B.J.; McCauley, E.W.

    1984-01-01

    In the Laser Fusion Program at Lawrence Livermore National Laboratory, a single laser fusion experiment lasts only a billionth of a second but in this time high speed instrumentation collects data that when digitized will create a data bank of several megabytes. This first level of data must be processed in several stages to put it in a form useful for interpretation of the experiments. One stage involves unfolding the source characteristics from the data and response of the instrument. This involves calculating the response of the instrument from the characteristics of each of its components. It is in this calculation that the ORACLE DBMS has become an invaluable tool for manipulation and archiving of the component data

  6. Obtaining the neutron time-of-flight instrument response function for a single D-T neutron utilizing n-alpha coincidence from the d(t, α) n nuclear reaction

    Science.gov (United States)

    Styron, Jedediah; Ruiz, Carlos; Hahn, Kelly; Cooper, Gary; Chandler, Gordon; Jones, Brent; McWatters, Bruce; Smith, Jenny; Vaughan, Jeremy

    2017-10-01

    A measured neutron time-of-flight (nTOF) signal is a convolution of the neutron reaction history and the instrument response function (IRF). For this work, the IRF was obtained by measuring single, D-T neutron events by utilizing n-alpha coincidence. The d(t, α) n nuclear reaction was produced at Sandia National Laboratories' Ion Beam Laboratory using a 300-keV Cockroft-Walton generator to accelerate a 2- μA beam, of 175-keV D + ions, into a stationary, 2.6- μm, ErT2 target. Comparison of these results to those obtained using cosmic-rays and photons will be discussed. Sandia National Laboratories.

  7. A multi-functional testing instrument for heat assisted magnetic recording media

    International Nuclear Information System (INIS)

    Yang, H. Z.; Chen, Y. J.; Leong, S. H.; An, C. W.; Ye, K. D.; Hu, J. F.; Yin, M. J.

    2014-01-01

    With recent developments in heat assisted magnetic recording (HAMR), characterization of HAMR media is becoming very important. We present a multi-functional instrument for testing HAMR media, which integrates HAMR writing, reading, and a micro-magneto-optic Kerr effect (μ-MOKE) testing function. A potential application of the present instrument is to make temperature dependent magnetic property measurement using a pump-probe configuration. In the measurement, the media is heated up by a heating (intense) beam while a testing (weak) beam is overlapped with the heating beam for MOKE measurement. By heating the media with different heating beam power, magnetic measurements by MOKE at different temperatures can be performed. Compared to traditional existing tools such as the vibrating sample magnetometer, the present instrument provides localized and efficient heating at the measurement spot. The integration of HAMR writing and μ-MOKE system can also facilitate a localized full investigation of the magnetic media by potential correlation of HAMR head independent write/read performance to localized magnetic properties

  8. Response of Nuclear Power Plant Instrumentation Cables Exposed to Fire Conditions.

    Energy Technology Data Exchange (ETDEWEB)

    Muna, Alice Baca [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); LaFleur, Chris Bensdotter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brooks, Dusty Marie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-09-01

    This report presents the results of instrumentation cable tests sponsored by the US Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research and performed at Sandia National Laboratories (SNL). The goal of the tests was to assess thermal and electrical response behavior under fire-exposure conditions for instrumentation cables and circuits. The test objective was to assess how severe radiant heating conditions surrounding an instrumentation cable affect current or voltage signals in an instrumentation circuit. A total of thirty-nine small-scale tests were conducted. Ten different instrumentation cables were tested, ranging from one conductor to eight-twisted pairs. Because the focus of the tests was thermoset (TS) cables, only two of the ten cables had thermoplastic (TP) insulation and jacket material and the remaining eight cables were one of three different TS insulation and jacket material. Two instrumentation cables from previous cable fire testing were included, one TS and one TP. Three test circuits were used to simulate instrumentation circuits present in nuclear power plants: a 4–20 mA current loop, a 10–50 mA current loop and a 1–5 VDC voltage loop. A regression analysis was conducted to determine key variables affecting signal leakage time.

  9. ADMINISTRATIVE INSTRUMENTS IN IMPLEMENTING FUNCTIONAL STRATEGIES COMPETITIVENESS MANAGEMENT

    OpenAIRE

    Stankovska, Iryna

    2017-01-01

    The article explores the use of  аdministrative instruments in implementing functional strategies competitiveness management. Due to providing strategic financial management competitiveness the use of administrative levers of control in the formulation and implementation of financial strategies were investigated. System of financial policies forming by individual policies of  general financial strategy, which is an administrative levers of influence on implementation strategies, was proposed...

  10. Planck 2013 results. IV. Low Frequency Instrument beams and window functions

    DEFF Research Database (Denmark)

    Planck Collaboration,; Aghanim, N.; Armitage-Caplan, C.

    2014-01-01

    This paper presents the characterization of the in-flight beams, the beam window functions and the associated errors for the Planck Low Frequency Instrument (LFI). Knowledge of the beam profiles is the key to determining their imprint on the transfer function from the observed to the actual sky a...

  11. Planck 2013 results. IV. Low Frequency Instrument beams and window functions

    DEFF Research Database (Denmark)

    Planck Collaboration,; Aghanim, N.; Armitage-Caplan, C.

    2013-01-01

    This paper presents the characterization of the in-flight beams, the beam window functions and the associated errors for the Planck Low Frequency Instrument (LFI). Knowledge of the beam profiles is the key to determining their imprint on the transfer function from the observed to the actual sky a...

  12. A method for improving global pyranometer measurements by modeling responsivity functions

    Energy Technology Data Exchange (ETDEWEB)

    Lester, A. [Smith College, Northampton, MA 01063 (United States); Myers, D.R. [National Renewable Energy Laboratory, 1617 Cole Blvd., Golden, CO 80401 (United States)

    2006-03-15

    Accurate global solar radiation measurements are crucial to climate change research and the development of solar energy technologies. Pyranometers produce an electrical signal proportional to global irradiance. The signal-to-irradiance ratio is the responsivity (RS) of the instrument (RS=signal/irradiance=microvolts/(W/m{sup 2})). Most engineering measurements are made using a constant RS. It is known that RS varies with day of year, zenith angle, and net infrared radiation. This study proposes a method to find an RS function to model a pyranometer's changing RS. Using a reference irradiance calculated from direct and diffuse instruments, we found instantaneous RS for two global pyranometers over 31 sunny days in a two-year period. We performed successive independent regressions of the error between the constant and instantaneous RS with respect to zenith angle, day of year, and net infrared to obtain an RS function. An alternative method replaced the infrared regression with an independently developed technique to account for thermal offset. Results show improved uncertainties with the function method than with the single-calibration value. Lower uncertainties also occur using a black-and-white (8-48), rather than all-black (PSP), shaded pyranometer as the diffuse reference instrument. We conclude that the function method is extremely effective in reducing uncertainty in the irradiance measurements for global PSP pyranometers if they are calibrated at the deployment site. Furthermore, it was found that the function method accounts for the pyranometer's thermal offset, rendering further corrections unnecessary. The improvements in irradiance data achieved in this study will serve to increase the accuracy of solar energy assessments and atmospheric research. (author)

  13. CORPORATE SOCIAL RESPONSIBILITY AS AN INSTRUMENT OF SUSTAINABLE DEVELOPMENT OF PRODUCTION ENTERPRISES

    Directory of Open Access Journals (Sweden)

    Ewelina GAWEŁ

    2015-07-01

    Full Text Available The paper deals with the issue of corporate social responsibility as an instrument of operationalising the paradigm of sustainable development on the microeconomic level in the sector of production enterprises. It presents a genesis and importance of CSR and indicates the most relevant essential instruments of CSR implementation on an enterprise level. The paper also analyses endogenous and exogenous benefits from implementing CSR into the business practice.

  14. Psychometric performance and responsiveness of the functional outcomes of sleep questionnaire and sleep apnea quality of life instrument in a randomized trial: the HomePAP study.

    Science.gov (United States)

    Billings, Martha E; Rosen, Carol L; Auckley, Dennis; Benca, Ruth; Foldvary-Schaefer, Nancy; Iber, Conrad; Zee, Phyllis C; Redline, Susan; Kapur, Vishesh K

    2014-12-01

    Measures of health-related quality of life (HRQL) specific for sleep disorders have had limited psychometric evaluation in the context of randomized controlled trials (RCTs). We investigated the psychometric properties of the Functional Outcomes of Sleep Questionnaire (FOSQ) and Sleep Apnea Quality of Life Instrument (SAQLI). We evaluated the FOSQ and SAQLI construct and criterion validity, determined a minimally important difference, and assessed for associations of responsiveness to baseline subject characteristics and continuous positive airway pressure (CPAP) adherence in a RCT population. Secondary analysis of data collected in a multisite RCT of home versus laboratory-based diagnosis and treatment of obstructive sleep apnea (HomePAP trial). Individuals enrolled in the HomePAP trial (n = 335). N/A. The FOSQ and SAQLI subscores demonstrated high reliability and criterion validity, correlating with Medical Outcomes Study 36-Item Short Form Survey domains. Correlations were weaker with the Epworth Sleepiness Scale (ESS). Both the FOSQ and SAQLI scores improved after 3 mo with CPAP therapy. Averaging 4 h or more of CPAP use was associated with an increase in the FOSQ beyond the minimally important difference. Baseline depressive symptoms and sleepiness predicted FOSQ and SAQLI responsiveness; demographic, objective obstructive sleep apnea (OSA) severity and sleep habits were not predictive in linear regression. The FOSQ and SAQLI are responsive to CPAP intervention, with the FOSQ being more sensitive to differences in CPAP adherence than the SAQLI. These instruments provide unique information about health outcomes beyond that provided by changes in physiological measures of OSA severity (apnea-hypopnea index). Portable Monitoring for Diagnosis and Management of Sleep Apnea (HomePAP) URL: http://clinicaltrials.gov/show/NCT00642486. NIH clinical trials registry number: NCT00642486. © 2014 Associated Professional Sleep Societies, LLC.

  15. Psychometric properties of the Late-Life Function and Disability Instrument

    DEFF Research Database (Denmark)

    Beauchamp, Marla K; Schmidt, Catherine T; Pedersen, Mette M

    2014-01-01

    The choice of measure for use as a primary outcome in geriatric research is contingent upon the construct of interest and evidence for its psychometric properties. The Late-Life Function and Disability Instrument (LLFDI) has been widely used to assess functional limitations and disability...... in studies with older adults. The primary aim of this systematic review was to evaluate the current available evidence for the psychometric properties of the LLFDI....

  16. CRiSP: An Instrument for Assessing Student Perceptions of Classroom Response Systems

    Science.gov (United States)

    Richardson, Alice M.; Dunn, Peter K.; McDonald, Christine; Oprescu, Florin

    2015-08-01

    This paper describes the development and validation of an instrument for evaluating classroom response systems (CRS). While a number of studies evaluating CRS have been published to date, no standardised instrument exists as a means of evaluating the impact of using the CRS. This means that comparing the different systems, or evaluating the benefits of using the CRS in different ways or settings, is very difficult despite the number of published reports, as indicated by Kay and LeSage (2009). An instrument was developed, called the classroom response system perceptions (CRiSP) questionnaire, which allows the evaluation of varied CRS on three scales: the usability; the impact on student engagement; and the impact on student learning. The development of CRiSP was undertaken in three universities, using different CRS, and evaluated through focus groups, one-on-one interviews and a factor analysis of the survey responses. We found no evidence of difference on the scales according to gender or age groups. The final CRiSP questionnaire consists of 26 base questions, with additional optional questions available. This paper proposes that the CRiSP Questionnaire could, in its current state or with minor changes, be used to evaluate the impact on learning of other classroom technologies also.

  17. Atomic absorption instrument functional description

    International Nuclear Information System (INIS)

    Bystroff, R.I.; Boyle, W.G. Jr.; Barton, G.W. Jr.

    1976-01-01

    This report describes a proposed system for automating atomic absorption analysis. The system consists of two atomic absorption instruments and an automatic sampler that can be attached to either instrument. A computer program controls the sampling and gathers data. The program then uses the data to perform bookkeeping, data processing, and report writing

  18. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. An inspector-instrument interface design that allows communication of procedures, responses, and results between the instrument and user is presented. This capability has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  19. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. This report describes an inspector-instrument interface design which allows communication of procedures, responses, and results between the instrument and user. The interface has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  20. Structural and functional plasticity specific to musical training with wind instruments

    Directory of Open Access Journals (Sweden)

    Uk-Su eChoi

    2015-10-01

    Full Text Available Numerous neuroimaging studies have shown structural and functional changes resulting from musical training. Among these studies, changes in primary sensory areas are mostly related to motor functions. In this study, we looked for some similar functional and structural changes in other functional modalities, such as somatosensory function, by examining the effects of musical training with wind instruments. We found significant changes in two aspects of neuroplasticity, cortical thickness and resting-state neuronal networks. A group of subjects with several years of continuous musical training and who are currently playing in university wind ensembles showed differences in cortical thickness in lip- and tongue-related brain areas versus non-music playing subjects. Cortical thickness in lip-related brain areas was significantly thicker and that in tongue-related areas was significantly thinner in the music playing group compared with that in the non-music playing group. Association analysis of lip-related areas in the music playing group showed that the increase in cortical thickness was caused by musical training. In addition, seed-based correlation analysis showed differential activation in the precentral gyrus and supplementary motor areas between the music and non-music playing groups. These results suggest that high-intensity training with specific musical instruments could induce structural changes in related anatomical areas and could also generate a new functional neuronal network in the brain.

  1. Functional response to cholinesterase inhibitor therapy in a naturalistic Alzheimer’s disease cohort

    Directory of Open Access Journals (Sweden)

    Wattmo Carina

    2012-11-01

    Full Text Available Abstract Background Activities of daily living (ADL are an essential part of the diagnostic criteria for Alzheimer’s disease (AD. A decline in ADL affects independent living and has a strong negative impact on caregiver burden. Functional response to cholinesterase inhibitor (ChEI treatment and factors that might influence this response in naturalistic AD patients need investigating. The aim of this study was to identify the socio-demographic and clinical factors that affect the functional response after 6 months of ChEI therapy. Methods This prospective, non-randomised, multicentre study in a routine clinical setting included 784 AD patients treated with donepezil, rivastigmine or galantamine. At baseline and after 6 months of treatment, patients were assessed using several rating scales, including the Instrumental Activities of Daily Living (IADL scale, Physical Self-Maintenance Scale (PSMS and Mini-Mental State Examination (MMSE. Demographic and clinical characteristics were investigated at baseline. The functional response and the relationships of potential predictors were analysed using general linear models. Results After 6 months of ChEI treatment, 49% and 74% of patients showed improvement/no change in IADL and in PSMS score, respectively. The improved/unchanged patients exhibited better cognitive status at baseline; regarding improved/unchanged PSMS, patients were younger and used fewer anti-depressants. A more positive functional response to ChEI was observed in younger individuals or among those having the interaction effect of better preserved cognition and lower ADL ability. Patients with fewer concomitant medications or those using NSAIDs/acetylsalicylic acid showed a better PSMS response. Conclusions Critical characteristics that may influence the functional response to ChEI in AD were identified. Some predictors differed from those previously shown to affect cognitive response, e.g., lower cognitive ability and older age

  2. Impact of proof test interval and coverage on probability of failure of safety instrumented function

    International Nuclear Information System (INIS)

    Jin, Jianghong; Pang, Lei; Hu, Bin; Wang, Xiaodong

    2016-01-01

    Highlights: • Introduction of proof test coverage makes the calculation of the probability of failure for SIF more accurate. • The probability of failure undetected by proof test is independently defined as P TIF and calculated. • P TIF is quantified using reliability block diagram and simple formula of PFD avg . • Improving proof test coverage and adopting reasonable test period can reduce the probability of failure for SIF. - Abstract: Imperfection of proof test can result in the safety function failure of safety instrumented system (SIS) at any time in its life period. IEC61508 and other references ignored or only elementarily analyzed the imperfection of proof test. In order to further study the impact of the imperfection of proof test on the probability of failure for safety instrumented function (SIF), the necessity of proof test and influence of its imperfection on system performance was first analyzed theoretically. The probability of failure for safety instrumented function resulted from the imperfection of proof test was defined as probability of test independent failures (P TIF ), and P TIF was separately calculated by introducing proof test coverage and adopting reliability block diagram, with reference to the simplified calculation formula of average probability of failure on demand (PFD avg ). Research results show that: the shorter proof test period and the higher proof test coverage indicate the smaller probability of failure for safety instrumented function. The probability of failure for safety instrumented function which is calculated by introducing proof test coverage will be more accurate.

  3. Item response theory, computerized adaptive testing, and PROMIS: assessment of physical function.

    Science.gov (United States)

    Fries, James F; Witter, James; Rose, Matthias; Cella, David; Khanna, Dinesh; Morgan-DeWitt, Esi

    2014-01-01

    Patient-reported outcome (PRO) questionnaires record health information directly from research participants because observers may not accurately represent the patient perspective. Patient-reported Outcomes Measurement Information System (PROMIS) is a US National Institutes of Health cooperative group charged with bringing PRO to a new level of precision and standardization across diseases by item development and use of item response theory (IRT). With IRT methods, improved items are calibrated on an underlying concept to form an item bank for a "domain" such as physical function (PF). The most informative items can be combined to construct efficient "instruments" such as 10-item or 20-item PF static forms. Each item is calibrated on the basis of the probability that a given person will respond at a given level, and the ability of the item to discriminate people from one another. Tailored forms may cover any desired level of the domain being measured. Computerized adaptive testing (CAT) selects the best items to sharpen the estimate of a person's functional ability, based on prior responses to earlier questions. PROMIS item banks have been improved with experience from several thousand items, and are calibrated on over 21,000 respondents. In areas tested to date, PROMIS PF instruments are superior or equal to Health Assessment Questionnaire and Medical Outcome Study Short Form-36 Survey legacy instruments in clarity, translatability, patient importance, reliability, and sensitivity to change. Precise measures, such as PROMIS, efficiently incorporate patient self-report of health into research, potentially reducing research cost by lowering sample size requirements. The advent of routine IRT applications has the potential to transform PRO measurement.

  4. Instrument response measurements of ion mobility spectrometers in situ: maintaining optimal system performance of fielded systems

    Science.gov (United States)

    Wallis, Eric; Griffin, Todd M.; Popkie, Norm, Jr.; Eagan, Michael A.; McAtee, Robert F.; Vrazel, Danet; McKinly, Jim

    2005-05-01

    Ion Mobility Spectroscopy (IMS) is the most widespread detection technique in use by the military for the detection of chemical warfare agents, explosives, and other threat agents. Moreover, its role in homeland security and force protection has expanded due, in part, to its good sensitivity, low power, lightweight, and reasonable cost. With the increased use of IMS systems as continuous monitors, it becomes necessary to develop tools and methodologies to ensure optimal performance over a wide range of conditions and extended periods of time. Namely, instrument calibration is needed to ensure proper sensitivity and to correct for matrix or environmental effects. We have developed methodologies to deal with the semi-quantitative nature of IMS and allow us to generate response curves that allow a gauge of instrument performance and maintenance requirements. This instrumentation communicates to the IMS systems via a software interface that was developed in-house. The software measures system response, logs information to a database, and generates the response curves. This paper will discuss the instrumentation, software, data collected, and initial results from fielded systems.

  5. The association between singing and/or playing a musical instrument and cognitive functions in older adults.

    Science.gov (United States)

    Mansens, D; Deeg, D J H; Comijs, H C

    2017-05-19

    Cognitive decline happens to everyone when aging, but to some more than others. Studies with children, adults, and professional musicians suggest that making music could be associated with better cognitive functioning. In older adults however, this association is less well investigated, which is therefore the aim of this study. In this cross-sectional study data from 1101 participants aged 64 and older from the Longitudinal Aging Study Amsterdam were used. Multivariable linear regression analyses were performed to test the association between making music and cognitive functioning and time spent making music and cognitive functioning. ANCOVA analyses were performed to differentiate between participants who made no music, only sang, only played an instrument or both sang and played an instrument in terms of cognitive functioning. Making music was significantly positively associated with letter fluency, learning and attention/short-term memory. Time spent making music yielded no significant results. The ANCOVA analyses showed higher scores for participants who only played an instrument compared to participants who made no music on learning, working memory and processing speed. For processing speed the instrument only group also had a higher score than participants who only sang. Making music at least once every two weeks and especially playing a musical instrument, is associated with better attention, episodic memory and executive functions. The results suggest that making music might be a potential protective factor for cognitive decline; however, to support this notion a longitudinal study design is needed.

  6. Calculation of Multisphere Neutron Spectrometer Response Functions in Energy Range up to 20 MeV

    CERN Document Server

    Martinkovic, J

    2005-01-01

    Multisphere neutron spectrometer is a basic instrument of neutron measurements in the scattered radiation field at charged-particles accelerators for radiation protection and dosimetry purposes. The precise calculation of the spectrometer response functions is a necessary condition of the propriety of neutron spectra unfolding. The results of the response functions calculation for the JINR spectrometer with LiI(Eu) detector (a set of 6 homogeneous and 1 heterogeneous moderators, "bare" detector within cadmium cover and without it) at two geometries of the spectrometer irradiation - in uniform monodirectional and uniform isotropic neutron fields - are given. The calculation was carried out by the code MCNP in the neutron energy range 10$^{-8}$-20 MeV.

  7. Assessment of the measurement properties of the post stroke motor function instruments available in Brazil: a systematic review.

    Science.gov (United States)

    Lima, Elaine; Teixeira-Salmela, Luci F; Simões, Luan; Guerra, Ana C C; Lemos, Andrea

    2016-03-15

    While there are several instruments in Brazil that measure motor function in patients after stroke, it is unknown whether the measurement properties of these instruments are appropriate. To identify the motor function instruments available in Brazil for patients after stroke. To assess the methodological quality of the studies and the results related to the measurement properties of these instruments. Two independent reviewers conducted searches on PubMed, LILACS, CINAHL, Web of Science, and Scopus. Studies that aimed to cross-culturally adapt an existing instrument or create a Brazilian instrument and test at least one measurement property related to motor function in patients after stroke were included. The methodological quality of these studies was checked by the COSMIN checklist with 4-point rating scale and the results of the measurement properties were analyzed by the criteria developed by Terwee et al. A total of 11 instruments were considered eligible, none of which were created in Brazil. The process of cross-cultural adaptation was inadequate in 10 out of 11 instruments due to the lack of back-translation or due to inappropriate target population. All of the instruments presented flaws in the measurement properties, especially reliability, internal consistency, and construct validity. The flaws observed in both cross-cultural adaptation process and testing measurement properties make the results inconclusive on the validity of the available instruments. Adequate procedures of cross-cultural adaptation and measurement properties of these instruments are strongly needed.

  8. Assessment of the measurement properties of the post stroke motor function instruments available in Brazil: a systematic review

    Directory of Open Access Journals (Sweden)

    Elaine Lima

    2016-01-01

    Full Text Available Background While there are several instruments in Brazil that measure motor function in patients after stroke, it is unknown whether the measurement properties of these instruments are appropriate. Objective To identify the motor function instruments available in Brazil for patients after stroke. To assess the methodological quality of the studies and the results related to the measurement properties of these instruments. Method Two independent reviewers conducted searches on PubMed, LILACS, CINAHL, Web of Science, and Scopus. Studies that aimed to cross-culturally adapt an existing instrument or create a Brazilian instrument and test at least one measurement property related to motor function in patients after stroke were included. The methodological quality of these studies was checked by the COSMIN checklist with 4-point rating scale and the results of the measurement properties were analyzed by the criteria developed by Terwee et al. Results A total of 11 instruments were considered eligible, none of which were created in Brazil. The process of cross-cultural adaptation was inadequate in 10 out of 11 instruments due to the lack of back-translation or due to inappropriate target population. All of the instruments presented flaws in the measurement properties, especially reliability, internal consistency, and construct validity. Conclusion The flaws observed in both cross-cultural adaptation process and testing measurement properties make the results inconclusive on the validity of the available instruments. Adequate procedures of cross-cultural adaptation and measurement properties of these instruments are strongly needed.

  9. Pilot dynamics for instrument approach tasks: Full panel multiloop and flight director operations

    Science.gov (United States)

    Weir, D. H.; Mcruer, D. T.

    1972-01-01

    Measurements and interpretations of single and mutiloop pilot response properties during simulated instrument approach are presented. Pilot subjects flew Category 2-like ILS approaches in a fixed base DC-8 simulaton. A conventional instrument panel and controls were used, with simulated vertical gust and glide slope beam bend forcing functions. Reduced and interpreted pilot describing functions and remmant are given for pitch attitude, flight director, and multiloop (longitudinal) control tasks. The response data are correlated with simultaneously recorded eye scanning statistics, previously reported in NASA CR-1535. The resulting combined response and scanning data and their interpretations provide a basis for validating and extending the theory of manual control displays.

  10. Responsiveness of five condition-specific and generic outcome assessment instruments for chronic pain

    Directory of Open Access Journals (Sweden)

    Verra Martin L

    2008-04-01

    Full Text Available Abstract Background Changes of health and quality-of-life in chronic conditions are mostly small and require specific and sensitive instruments. The aim of this study was to determine and compare responsiveness, i.e. the sensitivity to change of five outcome instruments for effect measurement in chronic pain. Methods In a prospective cohort study, 273 chronic pain patients were assessed on the Numeric Rating Scale (NRS for pain, the Short Form 36 (SF-36, the Multidimensional Pain Inventory (MPI, the Hospital Anxiety and Depression Scale (HADS, and the Coping Strategies Questionnaire (CSQ. Responsiveness was quantified by effect size (ES and standardized response mean (SRM before and after a four week in-patient interdisciplinary pain program and compared by the modified Jacknife test. Results The MPI measured pain more responsively than the SF-36 (ES: 0.85 vs 0.72, p = 0.053; SRM: 0.72 vs 0.60, p = 0.027 and the pain NRS (ES: 0.85 vs 0.62, p Conclusion The MPI was most responsive in all comparable domains followed by the SF-36. The pain-specific MPI and the generic SF-36 can be recommended for comprehensive and specific bio-psycho-social effect measurement of health and quality-of-life in chronic pain.

  11. Health Status Measurement Instruments in Chronic Obstructive Pulmonary Disease

    Directory of Open Access Journals (Sweden)

    Yves Lacasse

    1997-01-01

    Full Text Available Chronic obstructive pulmonary disease (COPD is associated with primary respiratory impairment, disability and handicap, as well as with secondary impairments not necessarily confined to the respiratory system. Because the primary goals of managing patients with COPD include relief of dyspnea and the improvement of health-related quality of life (HRQL, a direct measurement of HRQL is important. Fourteen disease-specific and nine generic questionnaires (four health profiles and five utility measures most commonly used to measure health status in patients with COPD were reviewed. The measures were classified according to their domain of interest, and their measurement properties - specifications, validity, reliability, responsiveness and interpretability - were described. This review suggests several findings. Currently used health status instruments usually refer to the patients’ perception of performance in three major domains of HRQL - somatic sensation, physical and occupational function, and psychological state. The choice of a questionnaire must be related to its purpose, with a clear distinction being made between its evaluative and discriminative function. In their evaluative function, only a few instruments fulfilled the criteria of responsiveness, and the interpretability of most questionnaires is limited. Generic questionnaires should not be used alone in clinical trials as evaluative instruments because of their inability to detect change over time. Further validation and improved interpretability of existing instruments would be of greater benefit to clinicians and scientists than the development of new questionnaires.

  12. Standard practice for instrumented indentation testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice defines the basic steps of Instrumented Indentation Testing (IIT) and establishes the requirements, accuracies, and capabilities needed by an instrument to successfully perform the test and produce the data that can be used for the determination of indentation hardness and other material characteristics. IIT is a mechanical test that measures the response of a material to the imposed stress and strain of a shaped indenter by forcing the indenter into a material and monitoring the force on, and displacement of, the indenter as a function of time during the full loading-unloading test cycle. 1.2 The operational features of an IIT instrument, as well as requirements for Instrument Verification Annex A1), Standardized Reference Blocks (Annex A2) and Indenter Requirements (Annex A3) are defined. This practice is not intended to be a complete purchase specification for an IIT instrument. 1.3 With the exception of the non-mandatory Appendix X4, this practice does not define the analysis necessary...

  13. The practical impact of differential item functioning analyses in a health-related quality of life instrument

    DEFF Research Database (Denmark)

    Scott, Neil W; Fayers, Peter M; Aaronson, Neil K

    2009-01-01

    Differential item functioning (DIF) analyses are commonly used to evaluate health-related quality of life (HRQoL) instruments. There is, however, a lack of consensus as to how to assess the practical impact of statistically significant DIF results.......Differential item functioning (DIF) analyses are commonly used to evaluate health-related quality of life (HRQoL) instruments. There is, however, a lack of consensus as to how to assess the practical impact of statistically significant DIF results....

  14. Validation of self-directed learning instrument and establishment of normative data for nursing students in taiwan: using polytomous item response theory.

    Science.gov (United States)

    Cheng, Su-Fen; Lee-Hsieh, Jane; Turton, Michael A; Lin, Kuan-Chia

    2014-06-01

    Little research has investigated the establishment of norms for nursing students' self-directed learning (SDL) ability, recognized as an important capability for professional nurses. An item response theory (IRT) approach was used to establish norms for SDL abilities valid for the different nursing programs in Taiwan. The purposes of this study were (a) to use IRT with a graded response model to reexamine the SDL instrument, or the SDLI, originally developed by this research team using confirmatory factor analysis and (b) to establish SDL ability norms for the four different nursing education programs in Taiwan. Stratified random sampling with probability proportional to size was used. A minimum of 15% of students from the four different nursing education degree programs across Taiwan was selected. A total of 7,879 nursing students from 13 schools were recruited. The research instrument was the 20-item SDLI developed by Cheng, Kuo, Lin, and Lee-Hsieh (2010). IRT with the graded response model was used with a two-parameter logistic model (discrimination and difficulty) for the data analysis, calculated using MULTILOG. Norms were established using percentile rank. Analysis of item information and test information functions revealed that 18 items exhibited very high discrimination and two items had high discrimination. The test information function was higher in this range of scores, indicating greater precision in the estimate of nursing student SDL. Reliability fell between .80 and .94 for each domain and the SDLI as a whole. The total information function shows that the SDLI is appropriate for all nursing students, except for the top 2.5%. SDL ability norms were established for each nursing education program and for the nation as a whole. IRT is shown to be a potent and useful methodology for scale evaluation. The norms for SDL established in this research will provide practical standards for nursing educators and students in Taiwan.

  15. Statistical power as a function of Cronbach alpha of instrument questionnaire items.

    Science.gov (United States)

    Heo, Moonseong; Kim, Namhee; Faith, Myles S

    2015-10-14

    In countless number of clinical trials, measurements of outcomes rely on instrument questionnaire items which however often suffer measurement error problems which in turn affect statistical power of study designs. The Cronbach alpha or coefficient alpha, here denoted by C(α), can be used as a measure of internal consistency of parallel instrument items that are developed to measure a target unidimensional outcome construct. Scale score for the target construct is often represented by the sum of the item scores. However, power functions based on C(α) have been lacking for various study designs. We formulate a statistical model for parallel items to derive power functions as a function of C(α) under several study designs. To this end, we assume fixed true score variance assumption as opposed to usual fixed total variance assumption. That assumption is critical and practically relevant to show that smaller measurement errors are inversely associated with higher inter-item correlations, and thus that greater C(α) is associated with greater statistical power. We compare the derived theoretical statistical power with empirical power obtained through Monte Carlo simulations for the following comparisons: one-sample comparison of pre- and post-treatment mean differences, two-sample comparison of pre-post mean differences between groups, and two-sample comparison of mean differences between groups. It is shown that C(α) is the same as a test-retest correlation of the scale scores of parallel items, which enables testing significance of C(α). Closed-form power functions and samples size determination formulas are derived in terms of C(α), for all of the aforementioned comparisons. Power functions are shown to be an increasing function of C(α), regardless of comparison of interest. The derived power functions are well validated by simulation studies that show that the magnitudes of theoretical power are virtually identical to those of the empirical power. Regardless

  16. Broadening of the x-ray emission line due to the instrumental function of the double-crystal spectrometer

    International Nuclear Information System (INIS)

    Tochio, T.; Ito, Y.; Omote, K.

    2002-01-01

    The influence of the instrumental function on the Cu Kα 1 emission line was investigated for the case of a double-crystal spectrometer. The magnitude of broadening for both Si(220) and Si(440) was calculated for a Lorentzian emission line with the width of 1-5 eV; the broadening for Si(220) is 0.12-0.18 eV while that for Si(440) is only 0.015-0.043 eV. The former is too large to be neglected, so the correction for the instrumental function is important. The spectrum affected by the instrumental function seems to keep the shape of Lorentzian though its width is larger. The fact indicates that the Lorentzian fitting analysis is effective if the appropriate correction for width is done

  17. Functional capabilities of the breadboard model of SIDRA satellite-borne instrument

    International Nuclear Information System (INIS)

    Dudnik, O.V.; Kurbatov, E.V.; Titov, K.G.; Prieto, M.; Sanchez, S.; Sylwester, J.; Gburek, S.; Podgorski, P.

    2013-01-01

    This paper presents the structure, principles of operation and functional capabilities of the breadboard model of SIDRA compact satellite-borne instrument. SIDRA is intended for monitoring fluxes of high-energy charged particles under outer-space conditions. We present the reasons to develop a particle spectrometer and we list the main objectives to be achieved with the help of this instrument. The paper describes the major specifications of the analog and digital signal processing units of the breadboard model. A specially designed and developed data processing module based on the Actel ProAsic3E A3PE3000 FPGA is presented and compared with the all-in one digital processing signal board based on the Xilinx Spartan 3 XC3S1500 FPGA.

  18. Content comparison of occupation-based instruments in adult rheumatology and musculoskeletal rehabilitation based on the International Classification of Functioning, Disability and Health.

    Science.gov (United States)

    Stamm, Tanja A; Cieza, Alarcos; Machold, Klaus P; Smolen, Josef S; Stucki, Gerold

    2004-12-15

    To compare the content of clinical, occupation-based instruments that are used in adult rheumatology and musculoskeletal rehabilitation in occupational therapy based on the International Classification of Functioning, Disability and Health (ICF). Clinical instruments of occupational performance and occupation in adult rehabilitation and rheumatology were identified in a literature search. All items of these instruments were linked to the ICF categories according to 10 linking rules. On the basis of the linking, the content of these instruments was compared and the relationship between the capacity and performance component explored. The following 7 instruments were identified: the Canadian Occupational Performance Measure, the Assessment of Motor and Process Skills, the Sequential Occupational Dexterity Assessment, the Jebson Taylor Hand Function Test, the Moberg Picking Up Test, the Button Test, and the Functional Dexterity Test. The items of the 7 instruments were linked to 53 different ICF categories. Five items could not be linked to the ICF. The areas covered by the 7 occupation-based instruments differ importantly: The main focus of all 7 instruments is on the ICF component activities and participation. Body functions are covered by 2 instruments. Two instruments were linked to 1 single ICF category only. Clinicians and researchers who need to select an occupation-based instrument must be aware of the areas that are covered by this instrument and the potential areas that are not covered at all.

  19. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1984-09-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  20. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1985-01-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  1. Structural, functional, and perceptual differences in Heschl's gyrus and musical instrument preference.

    Science.gov (United States)

    Schneider, Peter; Sluming, Vanessa; Roberts, Neil; Bleeck, Stefan; Rupp, André

    2005-12-01

    The musical pitch of harmonic complex sounds, such as instrumental sounds, is perceived primarily by decoding either the fundamental pitch (keynote) or spectral aspects of the stimuli, for example, single harmonics. We divided 334 professional musicians, including symphony orchestra musicians, 75 amateur musicians, and 54 nonmusicians, into either fundamental pitch listeners or spectral pitch listeners. We observed a strong correlation between pitch perception preference and asymmetry of brain structure and function in the pitch-sensitive lateral areas of Heschl's gyrus (HG), irrespective of musical ability. In particular, fundamental pitch listeners exhibited both larger gray matter volume measured using magnetic resonance imaging (MRI) and enhanced P50m activity measured using magnetoencephalography (MEG) in the left lateral HG, which is sensitive to rapid temporal processing. Their chosen instruments were percussive or high-pitched instruments that produce short, sharp, or impulsive tones (e.g., drums, guitar, piano, trumpet, or flute). By contrast, spectral pitch listeners exhibited a dominant right lateral HG, which is known to be sensitive to slower temporal and spectral processing. Their chosen instruments were lower-pitched melodic instruments that produce rather sustained tones with characteristic changes in timbre (e.g., bassoon, saxophone, french horn, violoncello, or organ). Singers also belonged to the spectral pitch listeners. Furthermore, the absolute size of the neural HG substrate depended strongly on musical ability. Overall, it is likely that both magnitude and asymmetry of lateral HG, and the related perceptual mode, may have an impact on preference for particular musical instruments and on musical performance.

  2. Verbal and Operant Responses of Young Children to Vocal Versus Instrumental Song Performances.

    Science.gov (United States)

    Sims, Wendy L.; Cassidy, Jane W.

    1997-01-01

    Reports on a study that investigated the effects of the presence or absence of lyrics in children's musical selections on young children's responses to music. The children responded to either recorded lullabies performed by a women singing, or a solo instrument, or separate pieces with and without lyrics. (MJP)

  3. Impact of instrument response variations on health physics measurements

    International Nuclear Information System (INIS)

    Armantrout, G.A.

    1984-10-01

    Uncertainties in estimating the potential health impact of a given radiation exposure include instrument measurement error in determining exposure and difficulty in relating this exposure to an effective dose value. Instrument error can be due to design or manufacturing deficiencies, limitations of the sensing element used, and calibration and maintenance of the instrument. This paper evaluates the errors which can be introduced by design deficiencies and limitations of the sensing element for a wide variety of commonly used survey instruments. The results indicate little difference among sensing element choice for general survey work, with variations among specific instrument designs being the major factor. Ion chamber instruments tend to be the best for all around use, while scintillator-based units should not be used where accurate measurements are required. The need to properly calibrate and maintain an instrument appears to be the most important factor in instrument accuracy. 8 references, 6 tables

  4. Response Time Analysis and Test of Protection System Instrument Channels for APR1400 and OPR1000

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Jae; Han, Seung; Yun, Jae Hee; Baek, Seung Min [Department of Instrumentation and Control System Engineering, KEPCO Engineering and Construction, Daejeon (Korea, Republic of); Lee, Sang Jeong [Department of Electronics Engineering, Chungnam National University, Daejeon (Korea, Republic of)

    2015-07-01

    , the establishment of the systematic response time evaluation methodology is needed to justify the conformance to the response time requirement used in the safety analysis. This paper proposes the response time evaluation methodology for APR1400 and OPR1000 using the combined analysis and test technique to confirm that the plant protection system can meet the analytical response time assumed in the safety analysis. In addition, the results of the quantitative evaluation performed for APR1400 and OPR1000 are presented in this paper. The proposed response time analysis technique consists of defining the response time requirement, determining the critical signal path for the trip parameter, allocating individual response time to each component on the signal path, and analyzing the total response time for the trip parameter, and demonstrates that the total analyzed response time does not exceed the response time requirement. The proposed response time test technique is composed of defining the response time requirement, determining the critical signal path for the trip parameter, determining the test method for each component on the signal path, performing the response time test, and demonstrates that the total test result does not exceed the response time requirement. The total response time should be tested in a single test that covers from the sensor to the final actuation device on the instrument channel. When the total channel is not tested in a single test, separate tests on groups of components or single components including the total instrument channel shall be combined to verify the total channel response. For APR1400 and OPR1000, the ramp test technique is used for the pressure and differential pressure transmitters and the step function testing technique is applied to the signal processing equipment and final actuation device. As a result, it can be demonstrated that the response time requirement is satisfied by the combined analysis and test technique

  5. Response Time Analysis and Test of Protection System Instrument Channels for APR1400 and OPR1000

    International Nuclear Information System (INIS)

    Lee, Chang Jae; Han, Seung; Yun, Jae Hee; Baek, Seung Min; Lee, Sang Jeong

    2015-01-01

    , the establishment of the systematic response time evaluation methodology is needed to justify the conformance to the response time requirement used in the safety analysis. This paper proposes the response time evaluation methodology for APR1400 and OPR1000 using the combined analysis and test technique to confirm that the plant protection system can meet the analytical response time assumed in the safety analysis. In addition, the results of the quantitative evaluation performed for APR1400 and OPR1000 are presented in this paper. The proposed response time analysis technique consists of defining the response time requirement, determining the critical signal path for the trip parameter, allocating individual response time to each component on the signal path, and analyzing the total response time for the trip parameter, and demonstrates that the total analyzed response time does not exceed the response time requirement. The proposed response time test technique is composed of defining the response time requirement, determining the critical signal path for the trip parameter, determining the test method for each component on the signal path, performing the response time test, and demonstrates that the total test result does not exceed the response time requirement. The total response time should be tested in a single test that covers from the sensor to the final actuation device on the instrument channel. When the total channel is not tested in a single test, separate tests on groups of components or single components including the total instrument channel shall be combined to verify the total channel response. For APR1400 and OPR1000, the ramp test technique is used for the pressure and differential pressure transmitters and the step function testing technique is applied to the signal processing equipment and final actuation device. As a result, it can be demonstrated that the response time requirement is satisfied by the combined analysis and test technique

  6. Climate policy instruments and industry-effects and potential responses in the Swedish context

    International Nuclear Information System (INIS)

    Johansson, Bengt

    2006-01-01

    Efficient policy instruments for reducing the emission of greenhouse gases are essential for the realisation of a successful climate policy. General economic policy instruments have the potential for providing efficient emission reduction as they equalise marginal costs for emission reduction between different actors. They also provide incentives for a great variety of responses such as energy efficiency improvements, fuel substitution and reduced consumption of carbon intensive products. However, as a result of the fact that it has so far been impossible to implement policy instruments on a global scale, these instruments are often adapted in such a way that some of their potential advantages are eliminated. In this paper the possibility of different policy instruments to contribute to reductions in industrial CO 2 emissions, while preserving the competitiveness of industry, is evaluated theoretically. The consequences of increasing the cost of CO 2 emission in various industrial sectors are also discussed. Attention is directed towards carbon taxes, emission trading (ET), and regulation. CO 2 taxes without tax reductions and ET with allocation through auctioning have theoretical advantages in a global climate regime but may lead to significant disadvantages if implemented in a single or a small groups of countries. ET with free intensity-based allocation would in this case have a major advantage in combining incentives for emission reductions through efficiency improvements and fuel substitution, with little impact on production levels

  7. CMOS Electrochemical Instrumentation for Biosensor Microsystems: A Review

    Directory of Open Access Journals (Sweden)

    Haitao Li

    2016-12-01

    Full Text Available Modern biosensors play a critical role in healthcare and have a quickly growing commercial market. Compared to traditional optical-based sensing, electrochemical biosensors are attractive due to superior performance in response time, cost, complexity and potential for miniaturization. To address the shortcomings of traditional benchtop electrochemical instruments, in recent years, many complementary metal oxide semiconductor (CMOS instrumentation circuits have been reported for electrochemical biosensors. This paper provides a review and analysis of CMOS electrochemical instrumentation circuits. First, important concepts in electrochemical sensing are presented from an instrumentation point of view. Then, electrochemical instrumentation circuits are organized into functional classes, and reported CMOS circuits are reviewed and analyzed to illuminate design options and performance tradeoffs. Finally, recent trends and challenges toward on-CMOS sensor integration that could enable highly miniaturized electrochemical biosensor microsystems are discussed. The information in the paper can guide next generation electrochemical sensor design.

  8. The cognitive functioning of older adult instrumental musicians and non-musicians.

    Science.gov (United States)

    Strong, Jessica V; Mast, Benjamin T

    2018-03-08

    This study examined similarities and differences in the cognitive profiles of older adult instrumental musicians and non-musicians. We compared neuropsychological test scores among older adult non-musicians, low-activity musicians (memory. The current study supports late life cognitive benefits of early musical training, but only in select cognitive domains, including language, executive functioning, and visual spatial ability. The results are discussed in the context of cognitive reserve and aging.

  9. Invited Article: Deep Impact instrument calibration.

    Science.gov (United States)

    Klaasen, Kenneth P; A'Hearn, Michael F; Baca, Michael; Delamere, Alan; Desnoyer, Mark; Farnham, Tony; Groussin, Olivier; Hampton, Donald; Ipatov, Sergei; Li, Jianyang; Lisse, Carey; Mastrodemos, Nickolaos; McLaughlin, Stephanie; Sunshine, Jessica; Thomas, Peter; Wellnitz, Dennis

    2008-09-01

    Calibration of NASA's Deep Impact spacecraft instruments allows reliable scientific interpretation of the images and spectra returned from comet Tempel 1. Calibrations of the four onboard remote sensing imaging instruments have been performed in the areas of geometric calibration, spatial resolution, spectral resolution, and radiometric response. Error sources such as noise (random, coherent, encoding, data compression), detector readout artifacts, scattered light, and radiation interactions have been quantified. The point spread functions (PSFs) of the medium resolution instrument and its twin impactor targeting sensor are near the theoretical minimum [ approximately 1.7 pixels full width at half maximum (FWHM)]. However, the high resolution instrument camera was found to be out of focus with a PSF FWHM of approximately 9 pixels. The charge coupled device (CCD) read noise is approximately 1 DN. Electrical cross-talk between the CCD detector quadrants is correctable to <2 DN. The IR spectrometer response nonlinearity is correctable to approximately 1%. Spectrometer read noise is approximately 2 DN. The variation in zero-exposure signal level with time and spectrometer temperature is not fully characterized; currently corrections are good to approximately 10 DN at best. Wavelength mapping onto the detector is known within 1 pixel; spectral lines have a FWHM of approximately 2 pixels. About 1% of the IR detector pixels behave badly and remain uncalibrated. The spectrometer exhibits a faint ghost image from reflection off a beamsplitter. Instrument absolute radiometric calibration accuracies were determined generally to <10% using star imaging. Flat-field calibration reduces pixel-to-pixel response differences to approximately 0.5% for the cameras and <2% for the spectrometer. A standard calibration image processing pipeline is used to produce archival image files for analysis by researchers.

  10. Invited Article: Deep Impact instrument calibration

    International Nuclear Information System (INIS)

    Klaasen, Kenneth P.; Mastrodemos, Nickolaos; A'Hearn, Michael F.; Farnham, Tony; Groussin, Olivier; Ipatov, Sergei; Li Jianyang; McLaughlin, Stephanie; Sunshine, Jessica; Wellnitz, Dennis; Baca, Michael; Delamere, Alan; Desnoyer, Mark; Thomas, Peter; Hampton, Donald; Lisse, Carey

    2008-01-01

    Calibration of NASA's Deep Impact spacecraft instruments allows reliable scientific interpretation of the images and spectra returned from comet Tempel 1. Calibrations of the four onboard remote sensing imaging instruments have been performed in the areas of geometric calibration, spatial resolution, spectral resolution, and radiometric response. Error sources such as noise (random, coherent, encoding, data compression), detector readout artifacts, scattered light, and radiation interactions have been quantified. The point spread functions (PSFs) of the medium resolution instrument and its twin impactor targeting sensor are near the theoretical minimum [∼1.7 pixels full width at half maximum (FWHM)]. However, the high resolution instrument camera was found to be out of focus with a PSF FWHM of ∼9 pixels. The charge coupled device (CCD) read noise is ∼1 DN. Electrical cross-talk between the CCD detector quadrants is correctable to <2 DN. The IR spectrometer response nonlinearity is correctable to ∼1%. Spectrometer read noise is ∼2 DN. The variation in zero-exposure signal level with time and spectrometer temperature is not fully characterized; currently corrections are good to ∼10 DN at best. Wavelength mapping onto the detector is known within 1 pixel; spectral lines have a FWHM of ∼2 pixels. About 1% of the IR detector pixels behave badly and remain uncalibrated. The spectrometer exhibits a faint ghost image from reflection off a beamsplitter. Instrument absolute radiometric calibration accuracies were determined generally to <10% using star imaging. Flat-field calibration reduces pixel-to-pixel response differences to ∼0.5% for the cameras and <2% for the spectrometer. A standard calibration image processing pipeline is used to produce archival image files for analysis by researchers.

  11. Parallel Study of HEND, RAD, and DAN Instrument Response to Martian Radiation and Surface Conditions

    Science.gov (United States)

    Martiniez Sierra, Luz Maria; Jun, Insoo; Litvak, Maxim; Sanin, Anton; Mitrofanov, Igor; Zeitlin, Cary

    2015-01-01

    Nuclear detection methods are being used to understand the radiation environment at Mars. JPL (Jet Propulsion Laboratory) assets on Mars include: Orbiter -2001 Mars Odyssey [High Energy Neutron Detector (HEND)]; Mars Science Laboratory Rover -Curiosity [(Radiation Assessment Detector (RAD); Dynamic Albedo Neutron (DAN))]. Spacecraft have instruments able to detect ionizing and non-ionizing radiation. Instrument response on orbit and on the surface of Mars to space weather and local conditions [is discussed] - Data available at NASA-PDS (Planetary Data System).

  12. Angle measurement with laser feedback instrument.

    Science.gov (United States)

    Chen, Wenxue; Zhang, Shulian; Long, Xingwu

    2013-04-08

    An instrument for angle measurement based on laser feedback has been designed. The measurement technique is based on the principle that when a wave plate placed into a feedback cavity rotates, its phase retardation varies. Phase retardation is a function of the rotating angle of the wave plate. Hence, the angle can be converted to phase retardation. The phase retardation is measured at certain characteristic points identified in the laser outputting curve that are then modulated by laser feedback. The angle of a rotating object can be measured if it is connected to the wave plate. The main advantages of this instrument are: high resolution, compact, flexible, low cost, effective power, and fast response.

  13. Safety and function of a new clinical intracerebral microinjection instrument for stem cells and therapeutics examined in the Göttingen minipig

    DEFF Research Database (Denmark)

    Bjarkam, Carsten R; GLUD, AN; Margolin, Lee

    2010-01-01

    Safety and function of a new clinical intracerebral microinjection instrument for stem cells and therapeutics examined in the Göttingen minipig......Safety and function of a new clinical intracerebral microinjection instrument for stem cells and therapeutics examined in the Göttingen minipig...

  14. Estudio del proceso de génesis instrumental del artefacto simbólico función exponencial Study of the process of instrumental genesis of the symbolic artifact for the exponential function

    Directory of Open Access Journals (Sweden)

    Mihály André Martínez Miraval

    2018-05-01

    Full Text Available This article describes a study of the exponential function on students of the first semester of a private University in Lima, Peru. The research was aimed at analyzing the Instrumental genesis process of this mathematical object assisted by the use of Geogebra software. Rabardel's Instrumental Approach was used as a theoretical framework. Likewise, some notions of Artigue's Didactic Engineering were used as a methodology, focusing on a priori and a posteriori analysis. The students’ answers allowed to identify the use of schemes built and activated, while interacting with the symbolic artifact for the exponential function. The use of Geogebra favored the instrumentalization and instrumentation of the addressed mathematical object since it allowed the students to validate their conjectures. Keywords:

  15. The Responsibility Of Trade Unions In Transaction Collective Instruments About Compensatory Time

    OpenAIRE

    Manuella de Oliveira Soares; Rui Carvalho Piva

    2016-01-01

    The democratic State of Direct aims to provide assurance and effectiveness of fundamental rights in order that human dignity is preserved. In this way, among other fundamental rights is the right to health, in one of its aspects, protects workers' health. Thus, this study, through a bibliographical research aims to demonstrate that unions should be held responsible for damage caused to workers when preparing collective bargaining instruments to the creation of compensatory time with condition...

  16. Measurement properties of instruments assessing permanent functional impairment of the spine: a systematic review protocol

    Science.gov (United States)

    Trask, Catherine M; Boden, Catherine; Bath, Brenna; Hendrick, Paul; Clay, Lynne; Zeng, Xiaoke; Milosavljevic, Stephan

    2018-01-01

    Introduction Permanent functional impairment (PFI) of the spine is a rating system used by compensation authorities, such as workers compensation boards, to establish an appropriate level of financial compensation for persistent loss of function. Determination of PFI of the spine is commonly based on the assessment of spinal movement combined with other measures of physical and functional impairments; however, the reliability and validity of the measurement instruments used for these evaluations have yet to be established. The aim of this study is to systematically review and synthesise the literature concerning measurement properties of the various and different instruments used for assessing PFI of the spine. Methods Three conceptual groups of terms (1) PFI, (2) spinal disorder and (3) measurement properties will be combined to search Medline, EMBASE, CINAHL, Web of Science, Scopus, PEDro, OTSeeker and Health and Safety Science Abstracts. We will examine peer-reviewed, full-text articles over the full available date range. Two reviewers will independently screen citations (title, abstract and full text) and perform data extraction. Included studies will be appraised as to their methodological quality using the COnsensus-based Standards for the selection of health Measurement INstruments criteria. Findings will be summarised and presented descriptively, with meta-analysis pursued as appropriate. Ethics and dissemination This review will summarise the current level of evidence of measurement properties of instruments used for assessing PFI of the spine. Findings of this review may be applicable to clinicians, policy-makers, workers’ compensation boards, other insurers and health and safety organisations. The findings will likely provide a foundation and direction for future research priorities for assessing spinal PFI. PROSPERO registration number CRD42017060390. PMID:29374671

  17. Kernel regression with functional response

    OpenAIRE

    Ferraty, Frédéric; Laksaci, Ali; Tadj, Amel; Vieu, Philippe

    2011-01-01

    We consider kernel regression estimate when both the response variable and the explanatory one are functional. The rates of uniform almost complete convergence are stated as function of the small ball probability of the predictor and as function of the entropy of the set on which uniformity is obtained.

  18. The blepharospasm disability scale: an instrument for the assessment of functional health in blepharospasm

    NARCIS (Netherlands)

    Lindeboom, R.; de Haan, R.; Aramideh, M.; Speelman, J. D.

    1995-01-01

    Assessment of the functional status in patients with blepharospasm is of major importance for clinical practice and outcome studies. The Blepharospasm Disability Scale (BDS) is specifically directed to measure the disability in these patients. The metric properties of this instrument were evaluated.

  19. The Nursing Home Minimum Data Set Assessment Instrument: Manifest Functions and Unintended Consequences--Past, Present, and Future

    Science.gov (United States)

    Rahman, Anna N.; Applebaum, Robert A.

    2009-01-01

    The Minimum Data Set (MDS) is a uniform instrument used in nursing homes to assess residents. In January 2008, the Centers for Medicare and Medicaid Services published a draft of a new MDS--version 3.0. This article traces the instrument's development and the design decisions that shaped it, discusses the MDS's manifest functions--data collection…

  20. Radiological emergency response - a functional approach

    International Nuclear Information System (INIS)

    Chowdhury, P.

    1998-01-01

    The state of Louisiana's radiological emergency response programme is based on the federal guidance 'Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants' (NUREG-0654, FEMA-REP-1 Rev. 1). Over the past 14 years, the planning and implementation of response capabilities became more organized and efficient; the training programme has strengthened considerably; co-ordination with all participating agencies has assumed a more co-operative role, and as a result, a fairly well integrated response planning has evolved. Recently, a more 'functional' approach is being adopted to maximize the programme's efficiency not only for nuclear power plant emergency response, but radiological emergency response as a whole. First, several broad-based 'components' are identified; clusters of 'nodes' are generated for each component; these 'nodes' may be divided into 'sub-nodes' which will contain some 'attributes'; 'relational bonds' among the 'attributes' will exist. When executed, the process begins and continues with the 'nodes' assuming a functional and dynamic role based on the nature and characteristics of the 'attributes'. The typical response based on stand-alone elements is thus eliminated, the overlapping of functions is avoided, and a well structured and efficient organization is produced, that is essential for today's complex nature of emergency response. (author)

  1. Seismic response and damage detection analyses of an instrumented steel moment-framed building

    Science.gov (United States)

    Rodgers, J.E.; Celebi, M.

    2006-01-01

    The seismic performance of steel moment-framed buildings has been of particular interest since brittle fractures were discovered at the beam-column connections in a number of buildings following the M 6.7 Northridge earthquake of January 17, 1994. A case study of the seismic behavior of an extensively instrumented 13-story steel moment frame building located in the greater Los Angeles area of California is described herein. Response studies using frequency domain, joint time-frequency, system identification, and simple damage detection analyses are performed using an extensive strong motion dataset dating from 1971 to the present, supported by engineering drawings and results of postearthquake inspections. These studies show that the building's response is more complex than would be expected from its highly symmetrical geometry. The response is characterized by low damping in the fundamental mode, larger accelerations in the middle and lower stories than at the roof and base, extended periods of vibration after the cessation of strong input shaking, beating in the response, elliptical particle motion, and significant torsion during strong shaking at the top of the concrete piers which extend from the basement to the second floor. The analyses conducted indicate that the response of the structure was elastic in all recorded earthquakes to date, including Northridge. Also, several simple damage detection methods employed did not indicate any structural damage or connection fractures. The combination of a large, real structure and low instrumentation density precluded the application of many recently proposed advanced damage detection methods in this case study. Overall, however, the findings of this study are consistent with the limited code-compliant postearthquake intrusive inspections conducted after the Northridge earthquake, which found no connection fractures or other structural damage. ?? ASCE.

  2. The Sandia transportable triggered lightning instrumentation facility

    Science.gov (United States)

    Schnetzer, George H.; Fisher, Richard J.

    1991-01-01

    Development of the Sandia Transportable Triggered Lightning Instrumentation Facility (SATTLIF) was motivated by a requirement for the in situ testing of a munitions storage bunker. Transfer functions relating the incident flash currents to voltages, currents, and electromagnetic field values throughout the structure will be obtained for use in refining and validating a lightning response computer model of this type of structure. A preliminary shakedown trial of the facility under actual operational conditions was performed during summer of 1990 at the Kennedy Space Center's (KSC) rocket-triggered lightning test site. A description is given of the SATTLIF, which is readily transportable on a single flatbed truck of by aircraft, and its instrumentation for measuring incident lightning channel currents and the responses of the systems under test. Measurements of return-stroke current peaks obtained with the SATTLIF are presented. Agreement with data acquired on the same flashes with existing KSC instrumentation is, on average, to within approximately 7 percent. Continuing currents were measured with a resolution of approximately 2.5 A. This field trial demonstrated the practicality of using a transportable triggered lightning facility for specialized test applications.

  3. Measurement properties of instruments assessing permanent functional impairment of the spine: a systematic review protocol.

    Science.gov (United States)

    Goes, Suelen Meira; Trask, Catherine M; Boden, Catherine; Bath, Brenna; Ribeiro, Daniel Cury; Hendrick, Paul; Clay, Lynne; Zeng, Xiaoke; Milosavljevic, Stephan

    2018-01-27

    Permanent functional impairment (PFI) of the spine is a rating system used by compensation authorities, such as workers compensation boards, to establish an appropriate level of financial compensation for persistent loss of function. Determination of PFI of the spine is commonly based on the assessment of spinal movement combined with other measures of physical and functional impairments; however, the reliability and validity of the measurement instruments used for these evaluations have yet to be established. The aim of this study is to systematically review and synthesise the literature concerning measurement properties of the various and different instruments used for assessing PFI of the spine. Three conceptual groups of terms (1) PFI, (2) spinal disorder and (3) measurement properties will be combined to search Medline, EMBASE, CINAHL, Web of Science, Scopus, PEDro, OTSeeker and Health and Safety Science Abstracts. We will examine peer-reviewed, full-text articles over the full available date range. Two reviewers will independently screen citations (title, abstract and full text) and perform data extraction. Included studies will be appraised as to their methodological quality using the COnsensus-based Standards for the selection of health Measurement INstruments criteria. Findings will be summarised and presented descriptively, with meta-analysis pursued as appropriate. This review will summarise the current level of evidence of measurement properties of instruments used for assessing PFI of the spine. Findings of this review may be applicable to clinicians, policy-makers, workers' compensation boards, other insurers and health and safety organisations. The findings will likely provide a foundation and direction for future research priorities for assessing spinal PFI. CRD42017060390. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise

  4. Planck 2015 results. IV. Low Frequency Instrument beams and window functions

    CERN Document Server

    Ade, P.A.R.; Ashdown, M.; Aumont, J.; Baccigalupi, C.; Banday, A.J.; Barreiro, R.B.; Bartolo, N.; Battaner, E.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.; Bernard, J.-P.; Bersanelli, M.; Bielewicz, P.; Bock, J.J.; Bonaldi, A.; Bonavera, L.; Bond, J.R.; Borrill, J.; Bouchet, F.R.; Bucher, M.; Burigana, C.; Butler, R.C.; Calabrese, E.; Cardoso, J.-F.; Catalano, A.; Chamballu, A.; Christensen, P.R.; Colombi, S.; Colombo, L.P.L.; Crill, B.P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R.D.; Davis, R.J.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Dickinson, C.; Diego, J.M.; Dole, H.; Donzelli, S.; Doré, O.; Douspis, M.; Ducout, A.; Dupac, X.; Efstathiou, G.; Elsner, F.; Enßlin, T.A.; Eriksen, H.K.; Fergusson, J.; Finelli, F.; Forni, O.; Frailis, M.; Franceschi, E.; Frejsel, A.; Galeotta, S.; Galli, S.; Ganga, K.; Giard, M.; Giraud-Héraud, Y.; Gjerløw, E.; González-Nuevo, J.; Górski, K.M.; Gratton, S.; Gregorio, A.; Gruppuso, A.; Hansen, F.K.; Hanson, D.; Harrison, D.L.; Henrot-Versillé, S.; Herranz, D.; Hildebrandt, S.R.; Hivon, E.; Hobson, M.; Holmes, W.A.; Hornstrup, A.; Hovest, W.; Huffenberger, K.M.; Hurier, G.; Jaffe, A.H.; Jaffe, T.R.; Juvela, M.; Keihänen, E.; Keskitalo, R.; Kiiveri, K.; Kisner, T.S.; Knoche, J.; Kunz, M.; Kurki-Suonio, H.; Lähteenmäki, A.; Lamarre, J.-M.; Lasenby, A.; Lattanzi, M.; Lawrence, C.R.; Leahy, J.P.; Leonardi, R.; Lesgourgues, J.; Levrier, F.; Liguori, M.; Lilje, P.B.; Linden-Vørnle, M.; Lindholm, V.; López-Caniego, M.; Lubin, P.M.; Macías-Pérez, J.F.; Maggio, G.; Maino, D.; Mandolesi, N.; Mangilli, A.; Maris, M.; Martin, P.G.; Martínez-González, E.; Masi, S.; Matarrese, S.; Mazzotta, P.; McGehee, P.; Meinhold, P.R.; Melchiorri, A.; Mendes, L.; Mennella, A.; Migliaccio, M.; Mitra, S.; Montier, L.; Morgante, G.; Mortlock, D.; Moss, A.; Munshi, D.; Murphy, J.A.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C.B.; Nørgaard-Nielsen, H.U.; Novikov, D.; Novikov, I.; Paci, F.; Pagano, L.; Paoletti, D.; Partridge, B.; Pasian, F.; Patanchon, G.; Pearson, T.J.; Perdereau, O.; Perotto, L.; Perrotta, F.; Pettorino, V.; Piacentini, F.; Pierpaoli, E.; Pietrobon, D.; Pointecouteau, E.; Polenta, G.; Pratt, G.W.; Prézeau, G.; Prunet, S.; Puget, J.-L.; Rachen, J.P.; Rebolo, R.; Reinecke, M.; Remazeilles, M.; Renzi, A.; Rocha, G.; Rosset, C.; Rossetti, M.; Roudier, G.; Rubiño-Martín, J.A.; Rusholme, B.; Sandri}, M.; Santos, D.; Savelainen, M.; Scott, D.; Seiffert, M.D.; Shellard, E.P.S.; Spencer, L.D.; Stolyarov, V.; Sutton, D.; Suur-Uski, A.-S.; Sygnet, J.-F.; Tauber, J.A.; Terenzi, L.; Toffolatti, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Tuovinen, J.; Umana, G.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vassallo, T.; Vielva, P.; Villa, F.; Wade, L.A.; Wandelt, B.D.; Watson, R.; Wehus, I.K.; Yvon, D.; Zacchei, A.

    2016-01-01

    This paper presents the characterization of the in-flight beams, the beam window functions, and the associated uncertainties for the Planck Low Frequency Instrument (LFI). The structure of the paper is similar to that presented in the 2013 Planck release; the main differences concern the beam normalization and the delivery of the window functions to be used for polarization analysis. The in-flight assessment of the LFI main beams relies on measurements performed during observations of Jupiter. By stacking data from seven Jupiter transits, the main beam profiles are measured down to -25 dB at 30 and 44 GHz, and down to -30 dB at 70 GHz. The agreement between the simulated beams and the measured beams is confirmed to be better than 1% at each LFI frequency band (within the 20 dB contour from the peak, the rms values are: 0.1% at 30 and 70 GHz; 0.2% at 44 GHz). Simulated polarized beams are used for the computation of the effective beam window functions. The error budget for the window functions is estimated fro...

  5. A low power consumption and multi-function mini-printer for the portable nuclear instruments

    International Nuclear Information System (INIS)

    Jin Yuheng; Zhang Jiahong

    1994-01-01

    The authors presents a method of fitting a commercial printing calculator to the low power consumption and multi-function mini-printer. It can be employed as a compact data recorder and simple data processing device attached to the portable nuclear instruments, which are powered by dry batteries

  6. Development of an instrument to measure behavioral health function for work disability: item pool construction and factor analysis.

    Science.gov (United States)

    Marfeo, Elizabeth E; Ni, Pengsheng; Haley, Stephen M; Jette, Alan M; Bogusz, Kara; Meterko, Mark; McDonough, Christine M; Chan, Leighton; Brandt, Diane E; Rasch, Elizabeth K

    2013-09-01

    To develop a broad set of claimant-reported items to assess behavioral health functioning relevant to the Social Security disability determination processes, and to evaluate the underlying structure of behavioral health functioning for use in development of a new functional assessment instrument. Cross-sectional. Community. Item pools of behavioral health functioning were developed, refined, and field tested in a sample of persons applying for Social Security disability benefits (N=1015) who reported difficulties working because of mental or both mental and physical conditions. None. Social Security Administration Behavioral Health (SSA-BH) measurement instrument. Confirmatory factor analysis (CFA) specified that a 4-factor model (self-efficacy, mood and emotions, behavioral control, social interactions) had the optimal fit with the data and was also consistent with our hypothesized conceptual framework for characterizing behavioral health functioning. When the items within each of the 4 scales were tested in CFA, the fit statistics indicated adequate support for characterizing behavioral health as a unidimensional construct along these 4 distinct scales of function. This work represents a significant advance both conceptually and psychometrically in assessment methodologies for work-related behavioral health. The measurement of behavioral health functioning relevant to the context of work requires the assessment of multiple dimensions of behavioral health functioning. Specifically, we identified a 4-factor model solution that represented key domains of work-related behavioral health functioning. These results guided the development and scale formation of a new SSA-BH instrument. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  7. Planck 2013 results. IV. Low Frequency Instrument beams and window functions

    CERN Document Server

    Aghanim, N; Arnaud, M; Ashdown, M; Atrio-Barandela, F; Aumont, J; Baccigalupi, C; Banday, A J; Barreiro, R B; Battaner, E; Benabed, K; Benoît, A; Benoit-Lévy, A; Bernard, J -P; Bersanelli, M; Bielewicz, P; Bobin, J; Bock, J J; Bonaldi, A; Bond, J R; Borrill, J; Bouchet, F R; Bridges, M; Bucher, M; Burigana, C; Butler, R C; Cardoso, J -F; Catalano, A; Chamballu, A; Chiang, L -Y; Christensen, P R; Church, S; Colombi, S; Colombo, L P L; Crill, B P; Curto, A; Cuttaia, F; Danese, L; Davies, R D; Davis, R J; de Bernardis, P; de Rosa, A; de Zotti, G; Delabrouille, J; Dickinson, C; Diego, J M; Dole, H; Donzelli, S; Doré, O; Douspis, M; Dupac, X; Efstathiou, G; Enßlin, T A; Eriksen, H K; Finelli, F; Forni, O; Frailis, M; Franceschi, E; Gaier, T C; Galeotta, S; Ganga, K; Giard, M; Giraud-Héraud, Y; González-Nuevo, J; Górski, K M; Gratton, S; Gregorio, A; Gruppuso, A; Hansen, F K; Hanson, D; Harrison, D; Henrot-Versillé, S; Hernández-Monteagudo, C; Herranz, D; Hildebrandt, S R; Hivon, E; Hobson, M; Holmes, W A; Hornstrup, A; Hovest, W; Huffenberger, K M; Jaffe, T R; Jaffe, A H; Jewell, J; Jones, W C; Juvela, M; Kangaslahti, P; Keihänen, E; Keskitalo, R; Kiiveri, K; Kisner, T S; Knoche, J; Knox, L; Kunz, M; Kurki-Suonio, H; Lagache, G; Lähteenmäki, A; Lamarre, J -M; Lasenby, A; Laureijs, R J; Lawrence, C R; Leahy, J P; Leonardi, R; Lesgourgues, J; Liguori, M; Lilje, P B; Lindholm, V; Linden-Vørnle, M; López-Caniego, M; Lubin, P M; Macías-Pérez, J F; Maino, D; Mandolesi, N; Maris, M; Marshall, D J; Martin, P G; Martínez-González, E; Masi, S; Matarrese, S; Matthai, F; Mazzotta, P; Meinhold, P R; Melchiorri, A; Mendes, L; Mennella, A; Migliaccio, M; Mitra, S; Moneti, A; Montier, L; Morgante, G; Mortlock, D; Moss, A; Munshi, D; Naselsky, P; Natoli, P; Netterfield, C B; Nørgaard-Nielsen, H U; Novikov, D; Novikov, I; O'Dwyer, I J; Osborne, S; Paci, F; Pagano, L; Paoletti, D; Partridge, B; Pasian, F; Patanchon, G; Perdereau, O; Perotto, L; Perrotta, F; Pierpaoli, E; Pietrobon, D; Plaszczynski, S; Platania, P; Pointecouteau, E; Polenta, G; Ponthieu, N; Popa, L; Poutanen, T; Pratt, G W; Prézeau, G; Prunet, S; Puget, J -L; Rachen, J P; Rebolo, R; Reinecke, M; Remazeilles, M; Ricciardi, S; Riller, T; Rocha, G; Rosset, C; Roudier, G; Rubiño-Martín, J A; Rusholme, B; Sandri, M; Santos, D; Scott, D; Seiffert, M D; Shellard, E P S; Spencer, L D; Starck, J -L; Stolyarov, V; Stompor, R; Sureau, F; Sutton, D; Suur-Uski, A -S; Sygnet, J -F; Tauber, J A; Tavagnacco, D; Terenzi, L; Toffolatti, L; Tomasi, M; Tristram, M; Tucci, M; Tuovinen, J; Türler, M; Umana, G; Valenziano, L; Valiviita, J; Van Tent, B; Varis, J; Vielva, P; Villa, F; Vittorio, N; Wade, L A; Wandelt, B D; Zacchei, A; Zonca, A

    2014-01-01

    This paper presents the characterization of the in-flight beams, the beam window functions and the associated uncertainties for the Planck Low Frequency Instrument (LFI). Knowledge of the beam profiles is necessary for determining the transfer function to go from the observed to the actual sky anisotropy power spectrum. The main beam distortions affect the beam window function, complicating the reconstruction of the anisotropy power spectrum at high multipoles, whereas the sidelobes affect the low and intermediate multipoles. The in-flight assessment of the LFI main beams relies on the measurements performed during Jupiter observations. By stacking the data from multiple Jupiter transits, the main beam profiles are measured down to -20 dB at 30 and 44 GHz, and down to -25 dB at 70 GHz. The main beam solid angles are determined to better than 0.2% at each LFI frequency band. The Planck pre-launch optical model is conveniently tuned to characterize the main beams independently of any noise effects. This approac...

  8. NaI(Tl) response functions

    International Nuclear Information System (INIS)

    Vega C, H. R.; Ortiz R, J. M.; Benites R, J. L.; De Leon M, H. A.

    2015-09-01

    The response functions of a NaI(Tl) detector have been estimated using Monte Carlo methods. Response functions were calculated for monoenergetic photon sources (0.05 to 3 MeV). Responses were calculated for point-like sources and for sources distributed in Portland cement cylinders. The responses were used to calculate the efficiency functions in term of photon energy. Commonly, sources used for calibration are point-like, and eventually sources to be measured have different features. In order to use the calibrated sources corrections due to solid angle, self-absorption and scattering, must be carried out. However, some of these corrections are not easy to perform. In this work, the calculated responses were used to estimate the detector efficiency of point-like sources, and sources distributed in Portland type cement. Samples of Portland paste were prepared and were exposed to photoneutrons produced by a 15 MV linac. Some of the elements in the cement were activated producing γ-emitting radionuclides that were measured with a NaI(Tl) gamma-ray spectrometer, that was calibrated with point-like sources. In order to determine the specific activity in the induced radioisotopes calculated efficiencies were used to make corrections due to the differences between the solid angle, photon absorption and photon scattering in the point-like calibration sources and the sources distributed in cement. During the interaction between photoneutrons and the cement samples three radioisotopes were induced: 56 Mn, 24 Na, and 28 Al. (Author)

  9. NaI(Tl) response functions

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H. R.; Ortiz R, J. M. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico); Benites R, J. L. [Centro Estatal de Cancerologia de Nayarit, Calz. de la Cruz 118 Sur, Tepic, Nayarit (Mexico); De Leon M, H. A., E-mail: fermineutron@yahoo.com.mx [Instituto Tecnologico de Aguascalientes, Av. Adolfo Lopez Mateos 1801 Ote., 20155 Aguascalientes, Ags. (Mexico)

    2015-09-15

    The response functions of a NaI(Tl) detector have been estimated using Monte Carlo methods. Response functions were calculated for monoenergetic photon sources (0.05 to 3 MeV). Responses were calculated for point-like sources and for sources distributed in Portland cement cylinders. The responses were used to calculate the efficiency functions in term of photon energy. Commonly, sources used for calibration are point-like, and eventually sources to be measured have different features. In order to use the calibrated sources corrections due to solid angle, self-absorption and scattering, must be carried out. However, some of these corrections are not easy to perform. In this work, the calculated responses were used to estimate the detector efficiency of point-like sources, and sources distributed in Portland type cement. Samples of Portland paste were prepared and were exposed to photoneutrons produced by a 15 MV linac. Some of the elements in the cement were activated producing γ-emitting radionuclides that were measured with a NaI(Tl) gamma-ray spectrometer, that was calibrated with point-like sources. In order to determine the specific activity in the induced radioisotopes calculated efficiencies were used to make corrections due to the differences between the solid angle, photon absorption and photon scattering in the point-like calibration sources and the sources distributed in cement. During the interaction between photoneutrons and the cement samples three radioisotopes were induced: {sup 56}Mn, {sup 24}Na, and {sup 28}Al. (Author)

  10. Evaluation of the measurement properties of self-reported health-related work-functioning instruments among workers with common mental disorders

    NARCIS (Netherlands)

    Abma, F.I.; van der Klink, J.J.L.; Terwee, C.B.; Amick, B.C.; Bultmann, U.

    2012-01-01

    Objectives During the past decade, common mental disorders (CMD) have emerged as a major public and occupational health problem in many countries. Several instruments have been developed to measure the influence of health on functioning at work. To select appropriate instruments for use in

  11. Local and linear chemical reactivity response functions at finite temperature in density functional theory

    International Nuclear Information System (INIS)

    Franco-Pérez, Marco; Ayers, Paul W.; Gázquez, José L.; Vela, Alberto

    2015-01-01

    We explore the local and nonlocal response functions of the grand canonical potential density functional at nonzero temperature. In analogy to the zero-temperature treatment, local (e.g., the average electron density and the local softness) and nonlocal (e.g., the softness kernel) intrinsic response functions are defined as partial derivatives of the grand canonical potential with respect to its thermodynamic variables (i.e., the chemical potential of the electron reservoir and the external potential generated by the atomic nuclei). To define the local and nonlocal response functions of the electron density (e.g., the Fukui function, the linear density response function, and the dual descriptor), we differentiate with respect to the average electron number and the external potential. The well-known mathematical relationships between the intrinsic response functions and the electron-density responses are generalized to nonzero temperature, and we prove that in the zero-temperature limit, our results recover well-known identities from the density functional theory of chemical reactivity. Specific working equations and numerical results are provided for the 3-state ensemble model

  12. Instrumentation Cables Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Muna, Alice Baca [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); LaFleur, Chris Bensdotter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-10-01

    A fire at a nuclear power plant (NPP) has the potential to damage structures, systems, and components important to safety, if not promptly detected and suppressed. At Browns Ferry Nuclear Power Plant on March 22, 1975, a fire in the reactor building damaged electrical power and control systems. Damage to instrumentation cables impeded the function of both normal and standby reactor coolant systems, and degraded the operators’ plant monitoring capability. This event resulted in additional NRC involvement with utilities to ensure that NPPs are properly protected from fire as intended by the NRC principle design criteria (i.e., general design criteria 3, Fire Protection). Current guidance and methods for both deterministic and performance based approaches typically make conservative (bounding) assumptions regarding the fire-induced failure modes of instrumentation cables and those failure modes effects on component and system response. Numerous fire testing programs have been conducted in the past to evaluate the failure modes and effects of electrical cables exposed to severe thermal conditions. However, that testing has primarily focused on control circuits with only a limited number of tests performed on instrumentation circuits. In 2001, the Nuclear Energy Institute (NEI) and the Electric Power Research Institute (EPRI) conducted a series of cable fire tests designed to address specific aspects of the cable failure and circuit fault issues of concern1. The NRC was invited to observe and participate in that program. The NRC sponsored Sandia National Laboratories to support this participation, whom among other things, added a 4-20 mA instrumentation circuit and instrumentation cabling to six of the tests. Although limited, one insight drawn from those instrumentation circuits tests was that the failure characteristics appeared to depend on the cable insulation material. The results showed that for thermoset insulated cables, the instrument reading tended to drift

  13. Instruments used to assess functional limitations in workers applying for disability benefit : a systematic review

    NARCIS (Netherlands)

    Spanjer, Jerry; Groothoff, Johan W.; Brouwer, Sandra

    2011-01-01

    Purpose. To systematically review the quality of the psychometric properties of instruments for assessing functional limitations in workers applying for disability benefit. Method. Electronic searches of Medline, Embase, CINAHL and PsycINFO were performed to identify studies focusing on the

  14. The Responsibility Of Trade Unions In Transaction Collective Instruments About Compensatory Time

    Directory of Open Access Journals (Sweden)

    Manuella de Oliveira Soares

    2016-12-01

    Full Text Available The democratic State of Direct aims to provide assurance and effectiveness of fundamental rights in order that human dignity is preserved. In this way, among other fundamental rights is the right to health, in one of its aspects, protects workers' health. Thus, this study, through a bibliographical research aims to demonstrate that unions should be held responsible for damage caused to workers when preparing collective bargaining instruments to the creation of compensatory time with conditions that endanger the health of workers .

  15. Response functions of the Andersson-Braun and extended range rem counters for neutron energies from thermal to 10 GeV

    CERN Document Server

    Mares, V; Schraube, H

    2002-01-01

    This work is devoted to the calculation of responses as functions of neutron energy for a paired set of Andersson-Braun rem counters, which is commercially available. Different Monte Carlo codes such as MCNP, LAHET, HADRON and MCNPX were applied in the calculations. The study extended to frontal, lateral and isotropic neutron incidence. For an estimation of the contribution of charged high-energy particles to the reading, the responses to protons and pions were also determined. The results obtained give good bases for the practical use of the new instrument in high-energy neutron fields.

  16. Temperature response functions (G-functions) for single pile heat exchangers

    International Nuclear Information System (INIS)

    Loveridge, Fleur; Powrie, William

    2013-01-01

    Foundation piles used as heat exchangers as part of a ground energy system have the potential to reduce energy use and carbon dioxide emissions from new buildings. However, current design approaches for pile heat exchangers are based on methods developed for boreholes which have a different geometry, with a much larger aspect (length to diameter) ratio. Current methods also neglect the transient behaviour of the pile concrete, instead assuming a steady state resistance for design purposes. As piles have a much larger volume of concrete than boreholes, this neglects the significant potential for heat storage within the pile. To overcome these shortcomings this paper presents new pile temperature response functions (G-functions) which are designed to reflect typical geometries of pile heat exchangers and include the transient response of the pile concrete. Owing to the larger number of pile sizes and pipe configurations which are possible with pile heat exchangers it is not feasible to developed a single unified G-function and instead upper and lower bound solutions are provided for different aspects ratios. - Highlights: • We present new temperature response functions for pile heat exchangers. • The functions include transient heat transfer within the pile concrete. • Application of the functions reduces the resulting calculated temperature ranges. • Greater energy efficiency is possible by accounting for heat storage in the pile

  17. The response of some health physics instruments to sodium-24 and chlorine-38 activities in polythene man-phantoms and the human body

    International Nuclear Information System (INIS)

    Peabody, C.O.

    1963-12-01

    Measurements have been made of the response of five commonly used Health Physics instruments when held near polythene man-phantoms filled with aqueous solutions containing sodium-24 and chlorine-38 activities. The instruments discussed are the Type 1413A, 1597A and 1368A ratemeters, the E.M.I. PCM1 contamination monitor and the Type 1021C beta-gamma probe. The ratios of the whole-body chlorine-38 and sodium-24 activities are calculated for various periods of accidental human irradiation by neutrons. These ratios and the phantom results are used to estimate the response of the five instruments when held near the human body at various times after irradiation. The relative contributions of the chlorine-38 and sodium-24 to the instrument indications are listed. The tabulated data enable the instrument readings to be converted to whole-body sodium-24 activity at the time of irradiation. This may be used as a quick estimate of the degree of neutron irradiation. (author)

  18. 78 FR 21128 - Molecular Diagnostic Instruments With Combined Functions; Draft Guidance for Industry and Food...

    Science.gov (United States)

    2013-04-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-D-0258] Molecular Diagnostic Instruments With Combined Functions; Draft Guidance for Industry and Food and Drug Administration Staff; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food...

  19. Evaluation of mode equivalence of the MSKCC Bowel Function Instrument, LASA Quality of Life, and Subjective Significance Questionnaire items administered by Web, interactive voice response system (IVRS), and paper.

    Science.gov (United States)

    Bennett, Antonia V; Keenoy, Kathleen; Shouery, Marwan; Basch, Ethan; Temple, Larissa K

    2016-05-01

    To assess the equivalence of patient-reported outcome (PRO) survey responses across Web, interactive voice response system (IVRS), and paper modes of administration. Postoperative colorectal cancer patients with home Web/e-mail and phone were randomly assigned to one of the eight study groups: Groups 1-6 completed the survey via Web, IVRS, and paper, in one of the six possible orders; Groups 7-8 completed the survey twice, either by Web or by IVRS. The 20-item survey, including the MSKCC Bowel Function Instrument (BFI), the LASA Quality of Life (QOL) scale, and the Subjective Significance Questionnaire (SSQ) adapted to bowel function, was completed from home on consecutive days. Mode equivalence was assessed by comparison of mean scores across modes and intraclass correlation coefficients (ICCs) and was compared to the test-retest reliability of Web and IVRS. Of 170 patients, 157 completed at least one survey and were included in analysis. Patients had mean age 56 (SD = 11), 53% were male, 81% white, 53% colon, and 47% rectal cancer; 78% completed all assigned surveys. Mean scores for BFI total score, BFI subscale scores, LASA QOL, and adapted SSQ varied by mode by less than one-third of a score point. ICCs across mode were: BFI total score (Web-paper = 0.96, Web-IVRS = 0.97, paper-IVRS = 0.97); BFI subscales (range = 0.88-0.98); LASA QOL (Web-paper = 0.98, Web-IVRS = 0.78, paper-IVRS = 0.80); and SSQ (Web-paper = 0.92, Web-IVRS = 0.86, paper-IVRS = 0.79). Mode equivalence was demonstrated for the BFI total score, BFI subscales, LASA QOL, and adapted SSQ, supporting the use of multiple modes of PRO data capture in clinical trials.

  20. Sum rules in the response function method

    International Nuclear Information System (INIS)

    Takayanagi, Kazuo

    1990-01-01

    Sum rules in the response function method are studied in detail. A sum rule can be obtained theoretically by integrating the imaginary part of the response function over the excitation energy with a corresponding energy weight. Generally, the response function is calculated perturbatively in terms of the residual interaction, and the expansion can be described by diagrammatic methods. In this paper, we present a classification of the diagrams so as to clarify which diagram has what contribution to which sum rule. This will allow us to get insight into the contributions to the sum rules of all the processes expressed by Goldstone diagrams. (orig.)

  1. Quantifying Human Response: Linking metrological and psychometric characterisations of Man as a Measurement Instrument

    International Nuclear Information System (INIS)

    Pendrill, L R; Fisher, William P Jr

    2013-01-01

    A better understanding of how to characterise human response is essential to improved person-centred care and other situations where human factors are crucial. Challenges to introducing classical metrological concepts such as measurement uncertainty and traceability when characterising Man as a Measurement Instrument include the failure of many statistical tools when applied to ordinal measurement scales and a lack of metrological references in, for instance, healthcare. The present work attempts to link metrological and psychometric (Rasch) characterisation of Man as a Measurement Instrument in a study of elementary tasks, such as counting dots, where one knows independently the expected value because the measurement object (collection of dots) is prepared in advance. The analysis is compared and contrasted with recent approaches to this problem by others, for instance using signal error fidelity

  2. Designing means and specifications for model FT-619 kidney function instrument

    International Nuclear Information System (INIS)

    Yu Yongding

    1988-04-01

    In this paper, it is pointed out that the model FT-619 Kidney Function Equipment is a new cost-effective nuclear medicine instrument, which takes the leading position in China. The performance of the model FT-619,especially the lead collimated scintillation detector has reached the same level as the advanced equipment in the world market. It is also described in this article in detail that the design of the lead collimator and the shielding as well as the detection efficiency have achieved the optimum level and that a comparison has been made with foreign products

  3. ARES: automated response function code. Users manual

    International Nuclear Information System (INIS)

    Maung, T.; Reynolds, G.M.

    1981-06-01

    This ARES user's manual provides detailed instructions for a general understanding of the Automated Response Function Code and gives step by step instructions for using the complete code package on a HP-1000 system. This code is designed to calculate response functions of NaI gamma-ray detectors, with cylindrical or rectangular geometries

  4. Environment for the instruments

    International Nuclear Information System (INIS)

    Ambro, P.

    1992-01-01

    A properly conditioned AC power supply is necessary for reliable functioning of instruments. Electric mains power is produced primarily for industry, workshops, lighting and household uses. Its quality is adjusted to these uses. In areas sand countries with a fast growing demand for electric power, these requirements are far from being met. Electronic instruments and computers, especially in these countries, need protection against disturbances of the mains supply. A clean and dry environment is needed for reliable functioning and long life of instruments. High humidity, specially at higher temperatures, changes the characteristics of electronic components. Moreover, under these conditions fungal growth causes leakage of currents and corrosion causes poor contacts. The presence of dust enhances these effects. They give rise to malfunction of instruments, particularly of high voltage equipment

  5. Environment for the instruments

    Energy Technology Data Exchange (ETDEWEB)

    Ambro, P

    1993-12-31

    A properly conditioned AC power supply is necessary for reliable functioning of instruments. Electric mains power is produced primarily for industry, workshops, lighting and household uses. Its quality is adjusted to these uses. In areas sand countries with a fast growing demand for electric power, these requirements are far from being met. Electronic instruments and computers, especially in these countries, need protection against disturbances of the mains supply. A clean and dry environment is needed for reliable functioning and long life of instruments. High humidity, specially at higher temperatures, changes the characteristics of electronic components. Moreover, under these conditions fungal growth causes leakage of currents and corrosion causes poor contacts. The presence of dust enhances these effects. They give rise to malfunction of instruments, particularly of high voltage equipment

  6. Response functions of free mass gravitational wave antennas

    Science.gov (United States)

    Estabrook, F. B.

    1985-01-01

    The work of Gursel, Linsay, Spero, Saulson, Whitcomb and Weiss (1984) on the response of a free-mass interferometric antenna is extended. Starting from first principles, the earlier work derived the response of a 2-arm gravitational wave antenna to plane polarized gravitational waves. Equivalent formulas (generalized slightly to allow for arbitrary elliptical polarization) are obtained by a simple differencing of the '3-pulse' Doppler response functions of two 1-arm antennas. A '4-pulse' response function is found, with quite complicated angular dependences for arbitrary incident polarization. The differencing method can as readily be used to write exact response functions ('3n+1 pulse') for antennas having multiple passes or more arms.

  7. Translation, Validation, and Reliability of the Dutch Late-Life Function and Disability Instrument Computer Adaptive Test.

    Science.gov (United States)

    Arensman, Remco M; Pisters, Martijn F; de Man-van Ginkel, Janneke M; Schuurmans, Marieke J; Jette, Alan M; de Bie, Rob A

    2016-09-01

    Adequate and user-friendly instruments for assessing physical function and disability in older adults are vital for estimating and predicting health care needs in clinical practice. The Late-Life Function and Disability Instrument Computer Adaptive Test (LLFDI-CAT) is a promising instrument for assessing physical function and disability in gerontology research and clinical practice. The aims of this study were: (1) to translate the LLFDI-CAT to the Dutch language and (2) to investigate its validity and reliability in a sample of older adults who spoke Dutch and dwelled in the community. For the assessment of validity of the LLFDI-CAT, a cross-sectional design was used. To assess reliability, measurement of the LLFDI-CAT was repeated in the same sample. The item bank of the LLFDI-CAT was translated with a forward-backward procedure. A sample of 54 older adults completed the LLFDI-CAT, World Health Organization Disability Assessment Schedule 2.0, RAND 36-Item Short-Form Health Survey physical functioning scale (10 items), and 10-Meter Walk Test. The LLFDI-CAT was repeated in 2 to 8 days (mean=4.5 days). Pearson's r and the intraclass correlation coefficient (ICC) (2,1) were calculated to assess validity, group-level reliability, and participant-level reliability. A correlation of .74 for the LLFDI-CAT function scale and the RAND 36-Item Short-Form Health Survey physical functioning scale (10 items) was found. The correlations of the LLFDI-CAT disability scale with the World Health Organization Disability Assessment Schedule 2.0 and the 10-Meter Walk Test were -.57 and -.53, respectively. The ICC (2,1) of the LLFDI-CAT function scale was .84, with a group-level reliability score of .85. The ICC (2,1) of the LLFDI-CAT disability scale was .76, with a group-level reliability score of .81. The high percentage of women in the study and the exclusion of older adults with recent joint replacement or hospitalization limit the generalizability of the results. The Dutch LLFDI

  8. Radiological emergency response - a functional approach

    International Nuclear Information System (INIS)

    Chowdhury, Prosanta

    1997-01-01

    The radiological emergency response program in the State of Louisiana is discussed. The improved approach intends to maximize the efficiency for both nuclear power plant and radiological emergency response as a whole. Several broad-based components are identified: cluster of 'nodes' are generated for each component; these 'nodes' may be divided into 'sub-nodes' which will contain some 'attributes'; 'relational bonds' among the 'attributes' will exist. When executed, the process begins and continues with the 'nodes' assuming a functional and dynamic role based on the nature and characteristics of the 'attributes'. The typical response based on stand-alone elements is eliminated; overlapping of functions is avoided, and is produced a well-structure and efficient organization

  9. The impact of instrumental feeding on children's responses to taste exposure.

    Science.gov (United States)

    Añez, E; Remington, A; Wardle, J; Cooke, L

    2013-10-01

    In a recent study, we showed that nonfood incentives combined with taste exposure increase children's acceptance of vegetables. However, the impact of children's previous experience of receiving food rewards is unknown. The present study investigated whether the experience of food rewards affects responses to an exposure-plus-reward intervention. One hundred and thirty-seven parents of 4-6-year-old children taking part in an exposure-based intervention study completed an instrumental feeding (IF) questionnaire aiming to assess their use of food rewards. Based on these scores, children were categorised as frequently or rarely instrumentally-fed. Intervention groups were given 12 daily tastes of a target vegetable combined with no reward, a tangible reward, (sticker) or a verbal reward (praise). A no-treatment control group received no tastings. Liking and intake of a target vegetable were measured at baseline and post-intervention. Irrespective of experience of IF, children in all intervention groups increased liking compared to controls (all P exposure group, only children with a limited experience with food rewards increased consumption (P mere exposure'. However, exposure with nonfood rewards can increase the acceptance of vegetables, regardless of previous experience. © 2012 The Authors Journal of Human Nutrition and Dietetics © 2012 The British Dietetic Association Ltd.

  10. AGE STRUCTURE OR FUNCTIONAL RESPONSE? RECONCILING ...

    African Journals Online (AJOL)

    ... surplus production that differ from traditional single-species management models. ... Specifically, while the ECOSIM “Arena” functional response and the von ... as a proxy for age structure rather than as a function of predator/prey behaviour, ...

  11. Core outcome measurement instruments for clinical trials in nonspecific low back pain

    Science.gov (United States)

    Chiarotto, Alessandro; Boers, Maarten; Deyo, Richard A.; Buchbinder, Rachelle; Corbin, Terry P.; Costa, Leonardo O.P.; Foster, Nadine E.; Grotle, Margreth; Koes, Bart W.; Kovacs, Francisco M.; Lin, C.-W. Christine; Maher, Chris G.; Pearson, Adam M.; Peul, Wilco C.; Schoene, Mark L.; Turk, Dennis C.; van Tulder, Maurits W.; Terwee, Caroline B.; Ostelo, Raymond W.

    2018-01-01

    Abstract To standardize outcome reporting in clinical trials of patients with nonspecific low back pain, an international multidisciplinary panel recommended physical functioning, pain intensity, and health-related quality of life (HRQoL) as core outcome domains. Given the lack of a consensus on measurement instruments for these 3 domains in patients with low back pain, this study aimed to generate such consensus. The measurement properties of 17 patient-reported outcome measures for physical functioning, 3 for pain intensity, and 5 for HRQoL were appraised in 3 systematic reviews following the COSMIN methodology. Researchers, clinicians, and patients (n = 207) were invited in a 2-round Delphi survey to generate consensus (≥67% agreement among participants) on which instruments to endorse. Response rates were 44% and 41%, respectively. In round 1, consensus was achieved on the Oswestry Disability Index version 2.1a for physical functioning (78% agreement) and the Numeric Rating Scale (NRS) for pain intensity (75% agreement). No consensus was achieved on any HRQoL instrument, although the Short Form 12 (SF12) approached the consensus threshold (64% agreement). In round 2, a consensus was reached on an NRS version with a 1-week recall period (96% agreement). Various participants requested 1 free-to-use instrument per domain. Considering all issues together, recommendations on core instruments were formulated: Oswestry Disability Index version 2.1a or 24-item Roland-Morris Disability Questionnaire for physical functioning, NRS for pain intensity, and SF12 or 10-item PROMIS Global Health form for HRQoL. Further studies need to fill the evidence gaps on the measurement properties of these and other instruments. PMID:29194127

  12. Planck 2013 results. VII. HFI time response and beams

    CERN Document Server

    Ade, P A R; Armitage-Caplan, C; Arnaud, M; Ashdown, M; Atrio-Barandela, F; Aumont, J; Baccigalupi, C; Banday, A J; Barreiro, R B; Battaner, E; Benabed, K; Benoît, A; Benoit-Lévy, A; Bernard, J -P; Bersanelli, M; Bielewicz, P; Bobin, J; Bock, J J; Bond, J R; Borrill, J; Bouchet, F R; Bowyer, J W; Bridges, M; Bucher, M; Burigana, C; Cardoso, J -F; Catalano, A; Challinor, A; Chamballu, A; Chary, R -R; Chiang, L -Y; Chiang, H C; Christensen, P R; Church, S; Clements, D L; Colombi, S; Colombo, L P L; Couchot, F; Coulais, A; Crill, B P; Curto, A; Cuttaia, F; Danese, L; Davies, R D; de Bernardis, P; de Rosa, A; de Zotti, G; Delabrouille, J; Delouis, J -M; Désert, F -X; Diego, J M; Dole, H; Donzelli, S; Doré, O; Douspis, M; Dunkley, J; Dupac, X; Efstathiou, G; Enßlin, T A; Eriksen, H K; Finelli, F; Forni, O; Frailis, M; Fraisse, A A; Franceschi, E; Galeotta, S; Ganga, K; Giard, M; Giraud-Héraud, Y; González-Nuevo, J; Górski, K M; Gratton, S; Gregorio, A; Gruppuso, A; Gudmundsson, J E; Haissinski, J; Hansen, F K; Hanson, D; Harrison, D; Henrot-Versillé, S; Hernández-Monteagudo, C; Herranz, D; Hildebrandt, S R; Hivon, E; Hobson, M; Holmes, W A; Hornstrup, A; Hou, Z; Hovest, W; Huffenberger, K M; Jaffe, T R; Jaffe, A H; Jones, W C; Juvela, M; Keihänen, E; Keskitalo, R; Kisner, T S; Kneissl, R; Knoche, J; Knox, L; Kunz, M; Kurki-Suonio, H; Lagache, G; Lamarre, J -M; Lasenby, A; Laureijs, R J; Lawrence, C R; Leonardi, R; Leroy, C; Lesgourgues, J; Liguori, M; Lilje, P B; Linden-Vørnle, M; López-Caniego, M; Lubin, P M; Macías-Pérez, J F; MacTavish, C J; Maffei, B; Mandolesi, N; Maris, M; Marshall, D J; Martin, P G; Martínez-González, E; Masi, S; Matarrese, S; Matsumura, T; Matthai, F; Mazzotta, P; McGehee, P; Melchiorri, A; Mendes, L; Mennella, A; Migliaccio, M; Mitra, S; Miville-Deschênes, M -A; Moneti, A; Montier, L; Morgante, G; Mortlock, D; Munshi, D; Murphy, J A; Naselsky, P; Nati, F; Natoli, P; Netterfield, C B; Nørgaard-Nielsen, H U; Noviello, F; Novikov, D; Novikov, I; Osborne, S; Oxborrow, C A; Paci, F; Pagano, L; Pajot, F; Paoletti, D; Pasian, F; Patanchon, G; Perdereau, O; Perotto, L; Perrotta, F; Piacentini, F; Piat, M; Pierpaoli, E; Pietrobon, D; Plaszczynski, S; Pointecouteau, E; Polegre, A M; Polenta, G; Ponthieu, N; Popa, L; Poutanen, T; Pratt, G W; Prézeau, G; Prunet, S; Puget, J -L; Rachen, J P; Reinecke, M; Remazeilles, M; Renault, C; Ricciardi, S; Riller, T; Ristorcelli, I; Rocha, G; Rosset, C; Roudier, G; Rowan-Robinson, M; Rusholme, B; Sandri, M; Santos, D; Sauvé, A; Savini, G; Shellard, E P S; Spencer, L D; Starck, J -L; Stolyarov, V; Stompor, R; Sudiwala, R; Sureau, F; Sutton, D; Suur-Uski, A -S; Sygnet, J -F; Tauber, J A; Tavagnacco, D; Terenzi, L; Tomasi, M; Tristram, M; Tucci, M; Umana, G; Valenziano, L; Valiviita, J; Van Tent, B; Vielva, P; Villa, F; Vittorio, N; Wade, L A; Wandelt, B D; Yvon, D; Zacchei, A; Zonca, A

    2014-01-01

    This paper characterizes the effective beams,the effective beam window functions and the associated errors for the Planck HFI detectors. The effective beam is the angular response including the effect of the optics,detectors,data processing and the scan strategy. The window function is the representation of this beam in the harmonic domain which is required to recover an unbiased measurement of the CMB angular power spectrum. The HFI is a scanning instrument and its effective beams are the convolution of: (a) the optical response of the telescope and feeds;(b)the processing of the time-ordered data and deconvolution of the bolometric and electronic time response; and (c) the merging of several surveys to produce maps. The time response functions are measured using observations of Jupiter and Saturn and by minimizing survey difference residuals. The scanning beam is the post-deconvolution angular response of the instrument, and is characterized with observations of Mars. The main beam solid angles are determin...

  13. Radiological emergency response - a functional approach

    Energy Technology Data Exchange (ETDEWEB)

    Chowdhury, Prosanta [Louisiana Radiation Protection Div., Baton Rouge, LA (United States)

    1997-12-31

    The radiological emergency response program in the State of Louisiana is discussed. The improved approach intends to maximize the efficiency for both nuclear power plant and radiological emergency response as a whole. Several broad-based components are identified: cluster of `nodes` are generated for each component; these `nodes` may be divided into `sub-nodes` which will contain some `attributes`; `relational bonds` among the `attributes` will exist. When executed, the process begins and continues with the `nodes` assuming a functional and dynamic role based on the nature and characteristics of the `attributes`. The typical response based on stand-alone elements is eliminated; overlapping of functions is avoided, and is produced a well-structure and efficient organization 1 ref., 6 figs.; e-mail: prosanta at deq.state.la.us

  14. Validation of Catquest-9SF-A Visual Disability Instrument to Evaluate Patient Function After Corneal Transplantation.

    Science.gov (United States)

    Claesson, Margareta; Armitage, W John; Byström, Berit; Montan, Per; Samolov, Branka; Stenvi, Ulf; Lundström, Mats

    2017-09-01

    Catquest-9SF is a 9-item visual disability questionnaire developed for evaluating patient-reported outcome measures after cataract surgery. The aim of this study was to use Rasch analysis to determine the responsiveness of Catquest-9SF for corneal transplant patients. Patients who underwent corneal transplantation primarily to improve vision were included. One group (n = 199) completed the Catquest-9SF questionnaire before corneal transplantation and a second independent group (n = 199) completed the questionnaire 2 years after surgery. All patients were recorded in the Swedish Cornea Registry, which provided clinical and demographic data for the study. Winsteps software v.3.91.0 (Winsteps.com, Beaverton, OR) was used to assess the fit of the Catquest-9SF data to the Rasch model. Rasch analysis showed that Catquest-9SF applied to corneal transplant patients was unidimensional (infit range, 0.73-1.32; outfit range, 0.81-1.35), and therefore, measured a single underlying construct (visual disability). The Rasch model explained 68.5% of raw variance. The response categories of the 9-item questionnaire were ordered, and the category thresholds were well defined. Item difficulty matched the level of patients' ability (0.36 logit difference between the means). Precision in terms of person separation (3.09) and person reliability (0.91) was good. Differential item functioning was notable for only 1 item (satisfaction with vision), which had a differential item functioning contrast of 1.08 logit. Rasch analysis showed that Catquest-9SF is a valid instrument for measuring visual disability in patients who have undergone corneal transplantation primarily to improve vision.

  15. Development of a Symptom-Based Patient-Reported Outcome Instrument for Functional Dyspepsia: A Preliminary Conceptual Model and an Evaluation of the Adequacy of Existing Instruments.

    Science.gov (United States)

    Taylor, Fiona; Reasner, David S; Carson, Robyn T; Deal, Linda S; Foley, Catherine; Iovin, Ramon; Lundy, J Jason; Pompilus, Farrah; Shields, Alan L; Silberg, Debra G

    2016-10-01

    The aim was to document, from the perspective of the empirical literature, the primary symptoms of functional dyspepsia (FD), evaluate the extent to which existing questionnaires target those symptoms, and, finally, identify any missing evidence that would impact the questionnaires' use in regulated clinical trials to assess treatment efficacy claims intended for product labeling. A literature review was conducted to identify the primary symptoms of FD and existing symptom-based FD patient-reported outcome (PRO) instruments. Following a database search, abstracts were screened and articles were retrieved for review. The primary symptoms of FD were organized into a conceptual model and the PRO instruments were evaluated for conceptual coverage as well as compared against evidentiary requirements presented in the FDA's PRO Guidance for Industry. Fifty-six articles and 16 instruments assessing FD symptoms were reviewed. Concepts listed in the Rome III criteria for FD (n = 7), those assessed by existing FD instruments (n = 34), and symptoms reported by patients in published qualitative research (n = 6) were summarized in the FD conceptual model. Except for vomiting, all of the identified symptoms from the published qualitative research reports were also specified in the Rome III criteria. Only three of the 16 instruments, the Dyspepsia Symptom Severity Index (DSSI), Nepean Dyspepsia Index (NDI), and Short-Form Nepean Dyspepsia Index (SF-NDI), measure all seven FD symptoms defined by the Rome III criteria. Among these three, each utilizes a 2-week recall period and 5-point Likert-type scale, and had evidence of patient involvement in development. Despite their coverage, when these instruments were evaluated in light of regulatory expectations, several issues jeopardized their potential qualification for substantiation of a labeling claim. No existing PRO instruments that measured all seven symptoms adhered to the regulatory principles necessary to support product

  16. Student Response to Faculty Instruction (SRFI): An Empirically Derived Instrument to Measure Student Evaluations of Teaching

    Science.gov (United States)

    Beitzel, Brian D.

    2013-01-01

    The Student Response to Faculty Instruction (SRFI) is an instrument designed to measure the student perspective on courses in higher education. The SRFI was derived from decades of empirical studies of student evaluations of teaching. This article describes the development of the SRFI and its psychometric attributes demonstrated in two pilot study…

  17. Use of microinterrupts to provide an instrument oriented input/output structure

    International Nuclear Information System (INIS)

    Zaky, S.G.

    1981-01-01

    This paper describes the design of a bit-slice based computer, which has been developed for use in data acquisition and control applications. The main design goals have been to provide fast response to external events, and sufficient processing capability to perform data reduction in real time. The initial application of this computer has been in airborne, geophysical surveying, where such instruments as Gamma-ray spectrometers, magnetometers and navigation equipment are involved. In order to meet the response requirement mentioned above, a microinterrupt facility has been incorporated. Microinterrupts are serviced in microcodes routines which can be initiated within a maximum of two microinstruction cycle times from an external event. This facility makes it possible to implement powerful input/output control functions without the need for complex and specialized hardware interfaces for each instrument. (orig.)

  18. Radiation protection instrument 1993

    International Nuclear Information System (INIS)

    1993-04-01

    The Radiation Protection Instrument, 1993 (Legislative Instrument 1559) prescribes the powers and functions of the Radiation Protection Board established under the Ghana Atomic Energy Commission by the Atomic Energy Commission (Amendment) Law, 1993 (P.N.D.C. Law 308). Also included in the Legislative Instrument are schedules on control and use of ionising radiation and radiation sources as well as procedures for notification, licensing and inspection of ionising radiation facilities. (EAA)

  19. Semiclassical theory for the nuclear response function

    International Nuclear Information System (INIS)

    Stroth, U.

    1986-01-01

    In the first part of this thesis it was demonstrated how on a semiclassical base a RPA theory is developed and applied to electron scattering. It was shown in which fields of nuclear physics this semiclassical theory can be applied and how it is to be understood. In this connection we dedicated an extensive discussion to the Fermi gas model. From the free response function we calculated the RPA response with a finite-range residual interaction which we completely antisymmetrize. In the second part of this thesis we studied with our theory (e,e') data for the separated response functions. (orig./HSI) [de

  20. Digital study of nuclear reactor instrument

    International Nuclear Information System (INIS)

    Lv Gongxiang; Yang Zhijun

    2006-01-01

    The paper introduces the design method of nuclear reactor's digital instrument developed by authors based on the AT89C52 single chip microcomputer. Also the instrument system hardware structure and software framework are given. The instrument apply DDC112 which is responsible for the measure of lower current. When designing the instrument system, anti-interference measure of software, especially hardware is considered seriously. (authors)

  1. Longitudinal and transverse quasielastic response functions of light nuclei

    International Nuclear Information System (INIS)

    Carlson, J.; Jourdan, J.; Sick, I.; Schiavilla, R.

    2002-01-01

    The 3 He and 4 He longitudinal and transverse response functions are determined from an analysis of the world data on quasielastic inclusive electron scattering. The corresponding Euclidean response functions are derived and compared to those calculated with Green's function Monte Carlo methods, using realistic interactions and currents. Large contributions associated with two-body currents are found, particularly in the 4 He transverse response, in agreement with data. The contributions of the two-body charge and current operators in the 3 He, 4 He, and 6 Li response functions are also studied via sum-rule techniques. A semiquantitative explanation for the observed systematics in the excess of transverse quasielastic strength, as function of mass number and momentum transfer, is provided. Finally, a number of model studies with simplified interactions, currents, and wave functions are carried out to elucidate the role played, in the full calculation, by tensor interactions and correlations

  2. Practical implications of neutron survey instrument performance

    International Nuclear Information System (INIS)

    Tanner, R. J.; Bartlett, D. T.; Hager, I. G.; Jones, I. N.; Molinos, C.; Roberts, N. J.; Taylor, G. C.; Thomas, D. J.

    2004-01-01

    Improvements have been made to the Monte Carlo modelling used to calculate the response of the neutron survey instruments most commonly used in the UK, for neutron energies up to 20 MeV. The improved modelling of the devices includes the electronics and battery pack, allowing better calculations of both the energy and angle dependence of response. These data are used to calculate the response of the instruments in rotationally and fully isotropic, as well as unidirectional fields. Experimental measurements with radionuclide sources and monoenergetic neutron fields have been, and continue to be made, to test the calculated response characteristics. The enhancements to the calculations have involved simulation of the sensitivity of the response to variations in instrument manufacture, and will include the influence of the user and floor during measurements. The practical implications of the energy and angle dependence of response, variations in manufacture, and the influence of the user are assessed by folding the response characteristics with workplace energy and direction distributions. (authors)

  3. On-ground calibration of the BEPICOLOMBO/SIMBIO-SYS at instrument level

    Science.gov (United States)

    Rodriguez-Ferreira, J.; Poulet, F.; Eng, P.; Longval, Y.; Dassas, K.; Arondel, A.; Langevin, Y.; Capaccioni, F.; Filacchione, G.; Palumbo, P.; Cremonese, G.; Dami, M.

    2012-04-01

    The Mercury Planetary Orbiter/BepiColombo carries an integrated suite of instruments, the Spectrometer and Imagers for MPO BepiColombo-Integrated Observatory SYStem (SIMBIO-SYS). SIMBIO-SYS has 3 channels: a stereo imaging system (STC), a high-resolution imager (HRIC) and a visible-near-infrared imaging spectrometer (VIHI). SIMBIO-SYS will scan the surface of Mercury with these three channels and determine the physical, morphological and compositional properties of the entire planet. Before integration on the S/C, an on-ground calibration at the channels and at the instrument levels will be performed so as to describe the instrumental responses as a function of various parameters that might evolve while the instruments will be operating [1]. The Institut d'Astrophysique Spatiale (IAS) is responsible for the on-ground instrument calibration at the instrument level. During the 4 weeks of calibration campaign planned for June 2012, the instrument will be maintained in a mechanical and thermal environment simulating the space conditions. Four Optical stimuli (QTH lamp, Integrating Sphere, BlackBody with variable temperature from 50 to 1200°C and Monochromator), are placed over an optical bench to illuminate the four channels so as to make the radiometric calibration, straylight monitoring, as well as spectral proofing based on laboratory mineral samples. The instrument will be mounted on a hexapod placed inside a thermal vacuum chamber during the calibration campaign. The hexapod will move the channels within the well-characterized incoming beam. We will present the key activities of the preparation of this calibration: the derivation of the instrument radiometric model, the implementation of the optical, mechanical and software interfaces of the calibration assembly, the characterization of the optical bench and the definition of the calibration procedures.

  4. Autoimmune Response Confers Decreased Cardiac Function in ...

    African Journals Online (AJOL)

    inflammatory response; rather, autoimmune response would keep affecting decreased heart function in. RHD patients who ... untreated children. Nearly 30 - 45 % of the affected children could ..... Technology Department of Anhui Province (PR.

  5. Higher-Level Hand Motor Function in Aging and (Preclinical) Dementia : Its Relationship with (Instrumental) Activities of Daily Life - A Mini-Review

    NARCIS (Netherlands)

    Scherder, Erik; Dekker, Welmoed; Eggermont, Laura

    2008-01-01

    A causal relationship between physical activity such as walking and cognitive functions - particularly executive functions and memory - has been observed in elderly people with and without dementia. Executive functions play an important role in the (instrumental) activities of daily life [(I)ADL].

  6. Development of network communication function for digitalized neutron flux monitoring instrument

    International Nuclear Information System (INIS)

    Li Kai; Zhang Liangju; Chen Xiaojun; Li Baoxiang

    2002-01-01

    It is essential for a digitalized Neutron Flux Monitoring Instrument to communicate with other parts of Instrumentation and Control System in a network environment, and it is fairly different from the case of traditional analogue nuclear instrumentation. How to satisfy all the requirements of different network structure and communication protocol, which might be adopted in different target nuclear power plant, is a key issue in the design and development of a digitalized neutron flux monitoring instrument. The author describes the overall communication scheme, mainly discusses the design idea and the requirements of the communication interfaces and the implementation of the RS-485 interface as an example of the digitalized neutron flux monitoring instrument, which is under development in the institute

  7. Response functions of superfluid neutron matter

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Jochen; Sedrakian, Armen [Institut fuer Theoretische Physik, Goethe Universitaet, 60438 Frankfurt/Main (Germany)

    2011-07-01

    We investigate the response of pair-correlated neutron matter under conditions relevant to neutron stars to external weak probes and compute its neutrino emissivity in vector and axialvector channels. To derive the response functions we sum up an infinite chain of particle-hole ladder diagrams within finite-temperature Green's function theory. The polarization tensor of matter is evaluated in the limit of small momentum transfers. The calculated neutrino emission via the weak neutral current processes of pair-breaking and recombination of Cooper-pairs in neutron stars causes a cooling of their baryonic interior, and represents an important mechanism for the thermal evolution of the star within a certain time domain.

  8. Small-angle scattering instruments on a 1 MW long pulse spallation source

    Energy Technology Data Exchange (ETDEWEB)

    Olah, G.A. [Los Alamos National Lab., Chemical Science and Tehcnology Div., Biosciences and Biotechnology Group, Los aalamos, NM (United States); Hjelm, R.P. [Los Alamos National Lab., Neutron Scattering Center, Los Alamos, NM (United States); Seeger, P.A.

    1995-11-01

    We have designed and optimized two small-angle neutron scattering instruments for installation at a 1 MW long pulse spallation source. The first of these instruments measures a Q-domain from 0.002 to 0.44 A{sup -1}, and the second instrument from 0.00069-0.17 A{sup -1}, Design characteristics were determined and optimization was done using a Monte Carlo instrument simulation package under development at Los alamos. A performance comparison was made between these instruments with D11 at the ILL by evaluating the scattered intensity and rms resolution for the instrument response function at different Q values for various instrument configurations needed to spn a Q-range of 0.0007-0.44 A{sup -1}. We concluded that the first of these instruments outperforms D11 in both intensity and resolution over most of the Q-domain and that the second is comparable to D11. Comparisons were also made of the performance of the optimized long pulse instruments with different reflectors and with a short pulse source, from which we concluded that there is an optimal moderator-reflector combination, and that a short pulse does not substantially improve the instrument performance. (author) 7 figs., 2 tabs., 9 refs.

  9. Small-angle scattering instruments on a 1 MW long pulse spallation source

    International Nuclear Information System (INIS)

    Olah, G.A.; Hjelm, R.P.; Seeger, P.A.

    1995-01-01

    We have designed and optimized two small-angle neutron scattering instruments for installation at a 1 MW long pulse spallation source. The first of these instruments measures a Q-domain from 0.002 to 0.44 A -1 , and the second instrument from 0.00069-0.17 A -1 , Design characteristics were determined and optimization was done using a Monte Carlo instrument simulation package under development at Los alamos. A performance comparison was made between these instruments with D11 at the ILL by evaluating the scattered intensity and rms resolution for the instrument response function at different Q values for various instrument configurations needed to spn a Q-range of 0.0007-0.44 A -1 . We concluded that the first of these instruments outperforms D11 in both intensity and resolution over most of the Q-domain and that the second is comparable to D11. Comparisons were also made of the performance of the optimized long pulse instruments with different reflectors and with a short pulse source, from which we concluded that there is an optimal moderator-reflector combination, and that a short pulse does not substantially improve the instrument performance. (author) 7 figs., 2 tabs., 9 refs

  10. Safeguarding the functions and performance of instrumentation and control systems

    International Nuclear Information System (INIS)

    Koehler, M.; Schoerner, O.

    1996-01-01

    Based on an analysis of the existing nuclear power plant control technology, the necessity of providing in the medium-term advanced and future-oriented, digital control system, both for normal operation and for safety-relevant tasks of the reactor and safety control systems. Siemens KWU has been promoting the development, review and marketing of the digital instrumentation and control systems called TELEPERM XS and TELEPERM XP in addition to the measures taken for safeguarding the functions of existing, wired systems. The paper briefly explains the performance and advantages of digital systems and the progress in approval and pioneering of the TELEPERM XS safety control system. Many examples discussed show the diversity of applications of the systems both in new reactor plants and as retrofitting measures, for KWU power plants and those of other manufacturers. (orig.) [de

  11. Micro-Arcsec mission: implications of the monitoring, diagnostic and calibration of the instrument response in the data reduction chain. .

    Science.gov (United States)

    Busonero, D.; Gai, M.

    The goals of 21st century high angular precision experiments rely on the limiting performance associated to the selected instrumental configuration and observational strategy. Both global and narrow angle micro-arcsec space astrometry require that the instrument contributions to the overall error budget has to be less than the desired micro-arcsec level precision. Appropriate modelling of the astrometric response is required for optimal definition of the data reduction and calibration algorithms, in order to ensure high sensitivity to the astrophysical source parameters and in general high accuracy. We will refer to the framework of the SIM-Lite and the Gaia mission, the most challenging space missions of the next decade in the narrow angle and global astrometry field, respectively. We will focus our dissertation on the Gaia data reduction issues and instrument calibration implications. We describe selected topics in the framework of the Astrometric Instrument Modelling for the Gaia mission, evidencing their role in the data reduction chain and we give a brief overview of the Astrometric Instrument Model Data Analysis Software System, a Java-based pipeline under development by our team.

  12. Instrumentation

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.G.

    1982-01-01

    This chapter reviews the parameters which are important to positron-imaging instruments. It summarizes the options which various groups have explored in designing tomographs and the methods which have been developed to overcome some of the limitations inherent in the technique as well as in present instruments. The chapter is not presented as a defense of positron imaging versus single-photon or other imaging modality, neither does it contain a description of various existing instruments, but rather stresses their common properties and problems. Design parameters which are considered are resolution, sampling requirements, sensitivity, methods of eliminating scattered radiation, random coincidences and attenuation. The implementation of these parameters is considered, with special reference to sampling, choice of detector material, detector ring diameter and shielding and variations in point spread function. Quantitation problems discussed are normalization, and attenuation and random corrections. Present developments mentioned are noise reduction through time-of-flight-assisted tomography and signal to noise improvements through high intrinsic resolution. Extensive bibliography. (U.K.)

  13. Electrophysiological responses to alcohol cues are not associated with Pavlovian-to-instrumental transfer in social drinkers.

    Directory of Open Access Journals (Sweden)

    Jasna Martinovic

    Full Text Available Pavlovian to Instrumental Transfer (PIT refers to the behavioral phenomenon of increased instrumental responding for a reinforcer when in the presence of Pavlovian conditioned stimuli that were separately paired with that reinforcer. PIT effects may play an important role in substance use disorders, but little is known about the brain mechanisms that underlie these effects in alcohol consumers. We report behavioral and electroencephalographic (EEG data from a group of social drinkers (n = 31 who performed a PIT task in which they chose between two instrumental responses in pursuit of beer and chocolate reinforcers while their EEG reactivity to beer, chocolate and neutral pictorial cues was recorded. We examined two markers of the motivational salience of the pictures: the P300 and slow wave event-related potentials (ERPs. Results demonstrated a behavioral PIT effect: responding for beer was increased when a beer picture was presented. Analyses of ERP amplitudes demonstrated significantly larger slow potentials evoked by beer cues at various electrode clusters. Contrary to hypotheses, there were no significant correlations between behavioral PIT effects, electrophysiological reactivity to the cues, and individual differences in drinking behaviour. Our findings are the first to demonstrate a PIT effect for beer, accompanied by increased slow potentials in response to beer cues, in social drinkers. The lack of relationship between behavioral and EEG measures, and between these measures and individual differences in drinking behaviour may be attributed to methodological features of the PIT task and to characteristics of our sample.

  14. Reactor instrumentation renewal of the TRIGA reactor Vienna, Austria

    International Nuclear Information System (INIS)

    Boeck, H.; Weiss, H.; Hood, W.E.; Hyde, W.K.

    1992-01-01

    The TRIGA Mark-II reactor at the Atominstitut in Vienna, Austria is replacing its twenty-four year old instrumentation system with a microprocessor based control system supplied by General Atomics. Ageing components, new governmental safety requirements and a need for state of the art instrumentation for training students has spurred the demand for new reactor instrumentation. In Austria a government appointed expert is assigned the responsibility of reviewing the proposed installation and verifying all safety aspects. After a positive review, final assembly and checkout of the instrumentation system may commence. The instrumentation system consists of three basic modules: the control system console, the data acquisition console and the NH-1000 wide range channel. Digital communications greatly reduce interwiring requirements. Hardwired safety channels are independent of computer control, thus, the instrumentation system in no way relies on any computer intervention for safety function. In addition, both the CSC and DAC computers are continuously monitored for proper operation via watchdog circuits which are capable of shutting down the reactor in the event of computer malfunction. Safety channels include two interlocked NMP-1000 multi-range linear channels for steady state mode, an NPP-1000 linear safety channel for pulse mode and a set of three independent fuel temperature monitoring channels. The microprocessor controlled wide range NM- 1000 digital neutron monitor (fission chamber based) functions as a startup/operational channel, and provides all power level related Interlocks. The Atominstitut TRIGA reactor is configured for four modes of operation: manual mode, automatic mode (servo control), pulsing mode and square wave mode. Control of the standard control rods is via stepping motor control rod drives, which offers the operator the choice of which control rods are operated by the servo system in automatic and square wave model. (author)

  15. Energy-environment policy goals and instruments and electricity demand response. A framework for the analysis

    International Nuclear Information System (INIS)

    Rio, Pablo del; Hernandez, F.

    2004-01-01

    The environment and energy realms have traditionally been two major focus of attention of EU and Member State (MS) policy. This attention has intensified in recent years as a response to, both, internal and external events and strategies (i.e., the Kyoto Protocol). In this context, the EU and its MS have set ambitious goals in the environmental and energy contexts and are already implementing packages of policies and measures. Both policies interact. Although there might be conflicts between both, there are also mutually reinforcing effects with significant policy implications. Actually, as stated in the Amsterdam Treaty, environmental protection is one of the major goals of energy policy (together with 'security of supply' and 'competitive energy systems'). On the other hand, the energy sector is instrumental in the success of environmental policy. In this context, a wide array of measures are currently being implemented in the EU and its MS which have a more or less direct impact on the electricity market. Particularly, Demand Side Management (DSM) activities, promotion of electricity from renewable energy sources (RES-E) and measures aimed at the mitigation of Greenhouse Gas (GHG) emissions are arguably three major instruments which have the potential to contribute to energy and environmental goals. The effectiveness and impact of there measures depends to a large extent on the demand response in the electricity market. Some of there measures affect the electricity demand curve, while others do not have a direct impact on the demand curve but affect the quantity of electricity demand by displacing the electricity supply curve. In turn, the effectiveness of energy and environmental policies may be different when electricity demand response varies (i.e., different elasticity demand). This paper entails an initial effort to provide a theoretical framework for the analysis of the interactions between electricity demand response and the above mentioned energy

  16. Silicon Drift Detector response function for PIXE spectra fitting

    Science.gov (United States)

    Calzolai, G.; Tapinassi, S.; Chiari, M.; Giannoni, M.; Nava, S.; Pazzi, G.; Lucarelli, F.

    2018-02-01

    The correct determination of the X-ray peak areas in PIXE spectra by fitting with a computer program depends crucially on accurate parameterization of the detector peak response function. In the Guelph PIXE software package, GUPIXWin, one of the most used PIXE spectra analysis code, the response of a semiconductor detector to monochromatic X-ray radiation is described by a linear combination of several analytical functions: a Gaussian profile for the X-ray line itself, and additional tail contributions (exponential tails and step functions) on the low-energy side of the X-ray line to describe incomplete charge collection effects. The literature on the spectral response of silicon X-ray detectors for PIXE applications is rather scarce, in particular data for Silicon Drift Detectors (SDD) and for a large range of X-ray energies are missing. Using a set of analytical functions, the SDD response functions were satisfactorily reproduced for the X-ray energy range 1-15 keV. The behaviour of the parameters involved in the SDD tailing functions with X-ray energy is described by simple polynomial functions, which permit an easy implementation in PIXE spectra fitting codes.

  17. Correlation of PROMIS Physical Function and Pain CAT Instruments With Oswestry Disability Index and Neck Disability Index in Spine Patients.

    Science.gov (United States)

    Papuga, Mark O; Mesfin, Addisu; Molinari, Robert; Rubery, Paul T

    2016-07-15

    A prospective and retrospective cross-sectional cohort analysis. The aim of this study was to show that Patient-Reported Outcomes Measurement Information System (PROMIS) computer adaptive testing (CAT) assessments for physical function and pain interference can be efficiently collected in a standard office visit and to evaluate these scores with scores from previously validated Oswestry Disability Index (ODI) and Neck Disability Index (NDI) providing evidence of convergent validity for use in patients with spine pathology. Spinal surgery outcomes are highly variable, and substantial debate continues regarding the role and value of spine surgery. The routine collection of patient-based outcomes instruments in spine surgery patients may inform this debate. Traditionally, the inefficiency associated with collecting standard validated instruments has been a barrier to routine use in outpatient clinics. We utilized several CAT instruments available through PROMIS and correlated these with the results obtained using "gold standard" legacy outcomes measurement instruments. All measurements were collected at a routine clinical visit. The ODI and the NDI assessments were used as "gold standard" comparisons for patient-reported outcomes. PROMIS CAT instruments required 4.5 ± 1.8 questions and took 35 ± 16 seconds to complete, compared with ODI/NDI requiring 10 questions and taking 188 ± 85 seconds when administered electronically. Linear regression analysis of retrospective scores involving a primary back complaint revealed moderate to strong correlations between ODI and PROMIS physical function with r values ranging from 0.5846 to 0.8907 depending on the specific assessment and patient subsets examined. Routine collection of physical function outcome measures in clinical practice offers the ability to inform and improve patient care. We have shown that several PROMIS CAT instruments can be efficiently administered during routine clinical visits. The

  18. The Development of an ASSA Module as an Auxiliary Tool for Assessment of Existing Plant Instrumentation and enhancement of the instruments performance

    International Nuclear Information System (INIS)

    Koo, Kil Mo; Kang, Kyung Ho; Ha, Kwang Soon; Cho, Young Ro; Cho, Young; Park, Rae Jun; Kim, Sang Baik; Kim, Hee Dong

    2007-04-01

    A review of a plant's accident management capabilities is one of the key elements in achieving regulatory closure of severe accident issues. During accidents, information and data from plant's instruments, as well as others sources, are essential for assessing the plant's status and response. Unlike for design basis accidents, there are inherently some uncertainties to instrumentation capabilities for severe accident conditions. There are many ways to obtain information during a severe accident. Moreover, precise measurements are not necessary. The redundancy and ruggedness of a plant's instrumentation provides considerable depth in the capability of existing designs. The circuit simulation analysis and diagnosis methods are used to assess instruments in detail when they give apparently abnormal readings. A new simulator, ASSA(abnormal signal simulator analysis), through an analysis of the important circuits modeling under severe accident conditions has been designed. It has three main functions which are a signal processing tool, an accident management tool, and an additional guide from the initial screen. In this paper, it can be simulated to the temperature characteristic analysis procedure of the ASSA through EQ data comparative method and using specific signal processing under severe accident condition

  19. An Examination of Embedding Character Education into the Daily Functions of High School Instrumental Music Ensembles

    Science.gov (United States)

    Sours, James P.

    2009-01-01

    This study was conducted to examine the effectiveness of embedding character education into the daily functions of instrumental music ensembles at Franklin High School in Portland Oregon. The participants in the study were the students of the researcher which may have been a delimitation. Their ages were from 14 to 19 years. Students from…

  20. Core outcome measurement instruments for clinical trials in non-specific low back pain

    DEFF Research Database (Denmark)

    Chiarotto, Alessandro; Boers, Maarten; Deyo, Richard A

    2017-01-01

    Disability Index version 2.1a (ODI 2.1a) for physical functioning (78% agreement) and the Numeric Rating Scale (NRS) for pain intensity (75% agreement). No consensus was achieved on any HRQoL instrument, although the Short Form 12 (SF12) approached the consensus threshold (64% agreement). In Round 2...... COSMIN methodology. Researchers, clinicians and patients (n = 207) were invited in a two-round Delphi survey to generate consensus ( ≥ 67% agreement among participants) on which instruments to endorse. Response rates were 44% and 41%, respectively. In Round 1, consensus was achieved on the Oswestry......, consensus was reached on a NRS version with a 1-week recall period (96% agreement). Various participants requested one free-to-use instrument per domain. Considering all issues together, recommendations on core instruments were formulated: ODI 2.1a or 24-item Roland-Morris Disability Questionnaire...

  1. Dynamic response function and large-amplitude dissipative collective motion

    International Nuclear Information System (INIS)

    Wu Xizhen; Zhuo Yizhong; Li Zhuxia; Sakata, Fumihiko.

    1993-05-01

    Aiming at exploring microscopic dynamics responsible for the dissipative large-amplitude collective motion, the dynamic response and correlation functions are introduced within the general theory of nuclear coupled-master equations. The theory is based on the microscopic theory of nuclear collective dynamics which has been developed within the time-dependent Hartree-Fock (TDHF) theory for disclosing complex structure of the TDHF-manifold. A systematic numerical method for calculating the dynamic response and correlation functions is proposed. By performing numerical calculation for a simple model Hamiltonian, it is pointed out that the dynamic response function gives an important information in understanding the large-amplitude dissipative collective motion which is described by an ensemble of trajectories within the TDHF-manifold. (author)

  2. Virtual instrumentation: a new approach for control and instrumentation - application in containment studies facility

    International Nuclear Information System (INIS)

    Gole, N.V.; Shanware, V.M.; Sebastian, A.; Subramaniam, K.

    2001-01-01

    PC based data-acquisition has emerged as a rapidly developing area particularly with respect to process instrumentation. Computer based data acquisition in process instrumentation combined with Supervisory Control and Data Acquisition (SCADA) software has introduced extensive possibilities with respect to formats for presentation of information. The concept of presenting data using any instrument format with the help of software tools to simulate the instrument on screen, needs to be understood, in order to be able to make use of its vast potential. The purpose of this paper is to present the significant features of the Virtual Instrumentation concept and discuss its application in the instrumentation and control system of containment studies facility (CSF). Factors involved in the development of the virtual instrumentation based I and C system for CSF are detailed and a functional overview of the system configuration is given. (author)

  3. Instruments and methods of scintillation spectra processing for radiation control tasks

    International Nuclear Information System (INIS)

    Antropov, S.Yu.; Ermilov, A.P.; Ermilov, S.A.; Komarov, N.A.; Krokhin, I.I.

    2005-01-01

    On gamma-spectrometer the response function could be calculated on the base of sensitivity data, energy resolution and form of Compton spectrum part. On the scintillation gamma-spectrometer with Na-I(Tl) crystal 63x63 mm the method allows to divide the 5-10 components mixtures, and on the beta-spectrometer of 2-3 component mixtures. The approach is realized in the 'Progress' program-instrumental complexes

  4. Alignment of Outcome Instruments Used in Hand Therapy With the Occupational Therapy Practice Framework: Domain and Process and the International Classification of Functioning, Disability and Health: A Scoping Review.

    Science.gov (United States)

    Lesher, Danielle Ann-Marie; Mulcahey, M J; Hershey, Peter; Stanton, Donna Breger; Tiedgen, Andrea C

    We sought to identify outcome instruments used in rehabilitation of the hand and upper extremity; to determine their alignment with the constructs of the International Classification of Functioning, Disability and Health (ICF) and the Occupational Therapy Practice Framework: Domain and Process; and to report gaps in the constructs measured by outcome instruments as a basis for future research. We searched CINAHL, MEDLINE, OTseeker, and the Cochrane Central Register of Controlled Trials using scoping review methodology and evaluated outcome instruments for concordance with the ICF and the Framework. We identified 18 outcome instruments for analysis. The findings pertain to occupational therapists' focus on body functions, body structures, client factors, and activities of daily living; a gap in practice patterns in use of instruments; and overestimation of the degree to which instruments used are occupationally based. Occupational therapy practitioners should use outcome instruments that embody conceptual frameworks for classifying function and activity. Copyright © 2017 by the American Occupational Therapy Association, Inc.

  5. Coping responses as predictors of psychosocial functioning ...

    African Journals Online (AJOL)

    ... West Haven-Yale Multidimensional Pain Inventory and the Coping Responses Inventory – Adult Form. The prevalence of the use of Avoidance and Approach Coping, and the relationship between these responses and psychosocial functioning (Pain Severity, Interference, Support, Life Control, and Affective Distress) were ...

  6. Differential item functioning (DIF) analyses of health-related quality of life instruments using logistic regression

    DEFF Research Database (Denmark)

    Scott, Neil W; Fayers, Peter M; Aaronson, Neil K

    2010-01-01

    Differential item functioning (DIF) methods can be used to determine whether different subgroups respond differently to particular items within a health-related quality of life (HRQoL) subscale, after allowing for overall subgroup differences in that scale. This article reviews issues that arise ...... when testing for DIF in HRQoL instruments. We focus on logistic regression methods, which are often used because of their efficiency, simplicity and ease of application....

  7. Development of Biomimetic and Functionally Responsive Surfaces

    Science.gov (United States)

    Anastasiadis, Spiros H.

    2010-03-01

    Controlling the surface morphology of solids and manufacturing of functional surfaces with special responsive properties has been the subject of intense research. We report a methodology for creating multifunctionally responsive surfaces by irradiating silicon wafers with femtosecond laser pulses and subsequently coating them with different types of functional conformal coatings. Such surfaces exhibit controlled dual-scale roughness at the micro- and the nano-scale, which mimics the hierarchical morphology of water repellent natural surfaces. When a simple alkylsilane coating is utilized, highly water repellent surfaces are produced that quantitatively compare to those of the Lotus leaf. When a polymer brush is ``grafted from" these surfaces based on a pH-sensitive polymer, the surfaces can alter their behavior from super-hydrophilic (after immersion in a low pH buffer) to super-hydrophobic and water-repellent (following immersion to a high pH buffer). We quantify the water repellency of such responsive systems by drop elasticity measurements whereas we demonstrate that the water repellent state of such surface requires appropriate hydrophobicity of the functionalizing polymer. When a photo-responsive azobenzene-type polymer is deposited, a dynamic optical control of the wetting properties is obtained and the surface can be switched from super-hydrophilic (following UV irradiation) to hydrophobic (following green irradiation). In all the above cases we show that the principal effect of roughness is to cause amplification of the response to the different external stimuli.

  8. Response function of spin-isospin nuclear excitations

    International Nuclear Information System (INIS)

    Salvetti, A.R.

    1986-01-01

    The selected aspects of spin-isospir nuclear excitations are studied. The spreading width of M/ states in even Ca isotopes for the purpose of trying to understand the missing strenght specially in 44 Ca, was estimated. The doorway calculation, was used, considering the level of complexity next to the independent particle M/ state. Using a nuclear matter context, the system response function to a spin-isospin probe and verify how the response function behaves for free fermions and in the ring approximation was studied. Higher correlations to polarization propagation such as the induced interaction and self-energy corrections was introduced. The dopping of colletive effects by such collisions terms was verified. It was investigate how to estimate the short range term of the effective interaction in the spin-isospin channel and the possibility of detecting a difference between these short range terms in the longitudinal and the transverse channel, for understanding the absence of pior condensation precursor states and negative results in a recent attempt to detect differences between longitudinal and transverse response functions one naively expects theoretically. (author) [pt

  9. Examining item content and structure in health status and health outcomes instruments: toward the development of a grammar for better understanding of the concepts being measured.

    Science.gov (United States)

    Erickson, Pennifer; Willke, Richard J

    2013-06-01

    Health outcomes instruments assess diverse health concepts. Although item-level concepts are considered fundamental elements, the field lacks structures for evaluating and organizing them for decision making. This article proposes a grammar using item stems, response options, and recall periods to systematically identify item-level concepts. The grammar uses "core concept," "evaluative component," and "recall period" as intuitive terms for communicating with stakeholders. Better characterization of concepts is necessary for classifying instrument content and linking it to treatment benefit. Items in 2 generic and 21 disease-specific instruments were evaluated to develop and illustrate the use of the grammar. Concepts were assigned International Classification of Functioning, Disability and Health codes for exploring the value that the grammar and a classification system add to the understanding of content across instruments. The 23 instruments include many core concepts; emotional function is the only concept assessed in all instruments. Concepts in disease-specific instruments show obvious patterns; for example, arthritis instruments focus on physical function. The majority of instruments used the same response options across all items, with five-point scales being the most common. Most instruments used one recall period for all items. Shorter recall periods were used for conditions associated with "flares," such as chronic obstructive pulmonary disease and "skin disease." Every diagnosis, however, showed variation across instruments in the recall period used. This analysis indicates the proposed grammar's potential for discerning the conceptual content within and between health outcomes instruments and illustrates its value for improving communication between stakeholders and for making decisions related to treatment benefit. Copyright © 2013 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  10. Development and Validation of a Quality-of-Life Instrument for Infantile Hemangiomas.

    Science.gov (United States)

    Chamlin, Sarah L; Mancini, Anthony J; Lai, Jin-Shei; Beaumont, Jennifer L; Cella, David; Adams, Denise; Drolet, Beth; Baselga, Eulalia; Frieden, Ilona J; Garzon, Maria; Holland, Kristin; Horii, Kimberly A; Lucky, Anne W; McCuaig, Catherine; Metry, Denise; Morel, Kimberly D; Newell, Brandon D; Nopper, Amy J; Powell, Julie; Siegel, Dawn; Haggstrom, Anita N

    2015-06-01

    Infantile hemangiomas (IH) are common tumors for which there is no validated disease-specific instrument to measure the quality of life in infants and their parents/caregivers during the critical first months of life. This study prospectively developed and validated a quality-of-life instrument for patients with IH and their parents/caregivers and correlated demographic and clinical features to the effects on the quality of life. A total of 220 parents/caregivers completed the 35-item Infantile Hemangioma Quality-of-Life (IH-QoL) instrument and provided demographic information. The dimensionality of the items was evaluated using factor analysis, with results suggesting four factors: child physical symptoms, child social interactions, parent emotional functioning, and parent psychosocial functioning. Each factor fit the Rasch measurement model with acceptable fit index (mean square instrument consists of four scales with a total of 29 items. Content validity was verified by analyzing parents' responses to an open-ended question. Test-retest reliability at a 48-hour interval was supported by a total IH-QoL intraclass correlation coefficient of 0.84. Certain clinical characteristics of hemangioma, including those located on the head and neck, in the proliferative stage, and requiring treatment, are associated with a greater impact on QoL.

  11. HTGR Measurements and Instrumentation Systems

    International Nuclear Information System (INIS)

    Ball, Sydney J.; Holcomb, David Eugene; Cetiner, Mustafa Sacit

    2012-01-01

    This report provides an integrated overview of measurements and instrumentation for near-term future high-temperature gas-cooled reactors (HTGRs). Instrumentation technology has undergone revolutionary improvements since the last HTGR was constructed in the United States. This report briefly describes the measurement and communications needs of HTGRs for normal operations, maintenance and inspection, fuel fabrication, and accident response. The report includes a description of modern communications technologies and also provides a potential instrumentation communications architecture designed for deployment at an HTGR. A principal focus for the report is describing new and emerging measurement technologies with high potential to improve operations, maintenance, and accident response for the next generation of HTGRs, known as modular HTGRs, which are designed with passive safety features. Special focus is devoted toward describing the failure modes of the measurement technologies and assessing the technology maturity.

  12. Incore instrument device

    International Nuclear Information System (INIS)

    Sakima, Naoki

    1996-01-01

    An incore instrument device has an integrally disposed touch panel having a function of displaying an operation indication method such as for setting of conditions for incore measurement and information processing and results of the incore measurement and a function capable of conducting operation indication such as for setting conditions and information processing for incore measurement relative to a control section upon touching an information position on a displayed information. In addition, an information processing section comprising a man-machine function program formed so as to recognize the content of the operation indication for the incore measurement by touching and let the control section to conduct it is disposed to the outside by way of a communication interface. In addition, a programming device is disposed for forming and rewriting the program of the man-machine function relative to the information processing section. Then, when various indication operations are conducted upon performing incore measurement, a view point can be concentrated to one predetermined point thereby enabling to improve the operationability without danger. In addition, the programming of the man-machine function does not apply unnecessary load to the control section in the incore instrumentation device. (N.H.)

  13. MACK/MACKLIB system for nuclear response functions

    International Nuclear Information System (INIS)

    Abdou, M.A.; Gohar, Y.M.

    1978-01-01

    The MACK computer program calculates energy pointwise and multigroup nuclear response functions from basic nuclear data in ENDF/B format. The new version of the program MACK-IV, incorporates major developments and improvements aimed at maximizing the utilization of available nuclear data and ensuring energy conservation in nuclear heating calculations. A new library, MACKLIB-IV, of nuclear response functions was generated in the CTR energy group structure of 171 neutron groups and 36 gamma groups. The library was prepared using MACK-IV and ENDF/B-IV and is suitable for fusion, fusion-fission hydrids, and fission applications

  14. MACK/MACKLIB system for nuclear response functions

    International Nuclear Information System (INIS)

    Abdou, M.A.; Gohar, Y.

    1978-01-01

    The MACK computer program calculates energy pointwise and multigroup nuclear response functions from basic nuclear data in ENDF/B format. The new version of the program, MACK-IV, incorporates major developments and improvements aimed at maximizing the utilization of available nuclear data and ensuring energy conservation in nuclear heating calculations. A new library, MACKLIB-IV, of nuclear response functions was generated in the CTR energy group structure of 171 neutron groups and 36 gamma groups. The library was prepared using MACK-IV, and ENDF/B-IV, and is suitable for fusion, fusion--fission hybrids, and fission applications. 3 figures, 4 tables

  15. MACK/MACKLIB system for nuclear response functions

    Energy Technology Data Exchange (ETDEWEB)

    Abdou, M.A.; Gohar, Y.M.

    1978-03-15

    The MACK computer program calculates energy pointwise and multigroup nuclear response functions from basic nuclear data in ENDF/B format. The new version of the program MACK-IV, incorporates major developments and improvements aimed at maximizing the utilization of available nuclear data and ensuring energy conservation in nuclear heating calculations. A new library, MACKLIB-IV, of nuclear response functions was generated in the CTR energy group structure of 171 neutron groups and 36 gamma groups. The library was prepared using MACK-IV and ENDF/B-IV and is suitable for fusion, fusion-fission hydrids, and fission applications.

  16. The Effectiveness of Singing or Playing a Wind Instrument in Improving Respiratory Function in Patients with Long-Term Neurological Conditions: A Systematic Review.

    Science.gov (United States)

    Ang, Kexin; Maddocks, Matthew; Xu, Huiying; Higginson, Irene J

    2017-03-01

    Many long-term neurological conditions adversely affect respiratory function. Singing and playing wind instruments are relatively inexpensive interventions with potential for improving respiratory function; however, synthesis of current evidence is needed to inform research and clinical use of music in respiratory care. To critically appraise, analyze, and synthesize published evidence on the effectiveness of singing or playing a wind instrument to improve respiratory function in people with long-term neurological conditions. Systematic review of published randomized controlled trials and observational studies examining singing or playing wind instruments to improve respiratory function in individuals with long-term neurological conditions. Articles meeting specified inclusion criteria were identified through a search of the Medline, Embase, PsycINFO, Cochrane Library, CINAHL, Web of Science, CAIRSS for Music, WHO International Clinical Trials Registry Platform Search Portal, and AMED databases as early as 1806 through March 2015. Information on study design, clinical populations, interventions, and outcome measures was extracted and summarized using an electronic standardized coding form. Methodological quality was assessed and summarized across studies descriptively. From screening 584 references, 68 full texts were reviewed and five studies included. These concerned 109 participants. The studies were deemed of low quality, due to evidence of bias, in part due to intervention complexity. No adverse effects were reported. Overall, there was a trend toward improved respiratory function, but only one study on Parkinson's disease had significant between-group differences. The positive trend in respiratory function in people with long-term neurological conditions following singing or wind instrument therapy is of interest, and warrants further investigation. © the American Music Therapy Association 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  17. Effects of Gas-Wall Partitioning in Teflon Tubing, Instrumentation and Other Materials on Time-Resolved Measurements of Gas-Phase Organic Compounds

    Science.gov (United States)

    Pagonis, D.; Deming, B.; Krechmer, J. E.; De Gouw, J. A.; Jimenez, J. L.; Ziemann, P. J.

    2017-12-01

    Recently it has been shown that gas-phase organic compounds partition to and from the walls of Teflon environmental chambers. This process is fast, reversible, and can be modeled as absorptive partitioning. Here these studies were extended to investigate gas-wall partitioning inside Teflon tubing by introducing step function changes in the concentration of compounds being sampled and measuring the delay in the response of a proton transfer reaction-mass spectrometer (PTR-MS). We find that these delays are significant for compounds with a saturation vapor concentration (c*) below 106 μg m-3, and that the Teflon tubing and the PTR-MS both contribute to the delays. Tubing delays range from minutes to hours under common sampling conditions and can be accurately predicted by a simple chromatography model across a range of tubing lengths and diameters, flow rates, compound functional groups, and c*. This method also allows one to determine the volatility-dependent response function of an instrument, which can be convolved with the output of the tubing model to correct for delays in instrument response time for these "sticky" compounds. This correction is expected to be of particular interest to researchers utilizing and developing chemical ionization mass spectrometry (CIMS) techniques, since many of the multifunctional organic compounds detected by CIMS show significant tubing and instrument delays. These results also enable better design of sampling systems, in particular when fast instrument response is needed, such as for rapid transients, aircraft, or eddy covariance measurements. Additional results presented here extend this method to quantify the relative sorptive capacities for other commonly used tubing materials, including PFA, FEP, PTFE, PEEK, glass, copper, stainless steel, and passivated steel.

  18. Chief Business Officers' Functions: Responsibilities and Importance.

    Science.gov (United States)

    Calver, Richard A.; Vogler, Daniel E.

    1985-01-01

    Reports on a survey of 177 chief business officers of public community colleges regarding their responsibilities and the importance they assigned to various role functions. Highlights findings concerning the perceived importance of fiscal/financial duties; endowments as a job function; role in shared planning; and personal attention given to…

  19. Reactor instrumentation experience at IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Soares, A.J.

    1997-01-01

    The Instituto de Pesquisas Energeticas e Nucleares (IPEN) in Sao Paulo started in 1977 development of nuclear instrumentation. In 1982 two groups were established, one responsible for maintenance of electronic equipment and the other, the Nuclear Instrumentation Section (NIS), for new projects, such as a light water moderated critical facility (IPEN/MB-0). The NIS had the responsibility to execute all necessary activities to develop the ''nonconventional'' instrumentation systems: control, protection and radiation monitoring for the IPEN/MB-01 facility. After the commissioning of the critical facility the NIS group started the development of instrumentation systems for a power reactor. As a first step an overall review of the quality assurance programme was implemented. In parallel the development of self powered detectors was carried out. (author). 7 figs

  20. Polarization response functions and the (/rvec e/,e'/rvec p/) reaction

    International Nuclear Information System (INIS)

    Picklesimer, A.; Van Orden, J.W.

    1988-01-01

    The first comprehensive study of the full set of eighteen response functions relevant to the (/rvec e/,e'/rvec p/) reaction is presented. Benchmark analytical features and limiting cases of the response functions are described. Numerical predictions contrasting nonrelativistic and relativistic (Dirac) dynamics and on- and off- shell final state interaction effects are presented. Basic physical characteristics and dependences of the response functions are identified. The outlook for future experimental studies of the (/rvec e/,e'/rvec p/) polarization response functions is discussed. 56 refs., 5 figs., 1 tab

  1. Portable neutron and gamma-radiation instruments

    International Nuclear Information System (INIS)

    Murray, W.S.; Butterfield, K.B.

    1990-01-01

    This paper reports on the design and building of a smart neutron and gamma-radiation detection systems with embedded microprocessors programmed in the FORTH language. These portable instruments can be battery-powered and can provide many analysis functions not available in most radiation detectors. Local operation of the instruments is menu-driven through a graphics liquid crystal display and hex keypad; remote operation is through a serial communications link. While some instruments simply count particles, others determine the energy of the radiation as well as the intensity. The functions the authors have provided include absolute source-strength determination. Feynmann variance analysis, sequential-probability ratio test, and time-history recording

  2. Maintenance of nuclear medicine instruments

    Energy Technology Data Exchange (ETDEWEB)

    Ambro, P

    1993-12-31

    Maintenance of instruments is generally of two kinds: (a) corrective maintenance, on a non-scheduled basis, to restore equipment to a functional status by repairs; (b) preventive maintenance, to keep equipment in a specified functional condition by providing systematic inspection, quality control, detection and correction of early malfunctions. Most of the instruments used in nuclear medicine are rather complex systems built from mechanical, electrical and electronic parts. Any one of these components is liable to fail at some time or other. Repair could be done only by a specialist who is able to evaluate the condition of the various parts ranging from cables to connectors, from scintillators to photomultipliers, from microprocessors to microswitches. The knowledge of the intricacies of the various electronic components required for their repairs is quite wide and varied. The electronics industry turns out more and more multi-purpose chips which can carry out the functions of many parts used in the instruments of the earlier generation. This provides protection against unauthorized copying of the circuits but it serves another purpose as well of inhibiting repairs by non-factory personnel. These trends of the instrument design should be taken into consideration when a policy has to be developed for the repairs of the hospital based equipment 1 fig., 1 tab

  3. Maintenance of nuclear medicine instruments

    International Nuclear Information System (INIS)

    Ambro, P.

    1992-01-01

    Maintenance of instruments is generally of two kinds: (a) corrective maintenance, on a non-scheduled basis, to restore equipment to a functional status by repairs; (b) preventive maintenance, to keep equipment in a specified functional condition by providing systematic inspection, quality control, detection and correction of early malfunctions. Most of the instruments used in nuclear medicine are rather complex systems built from mechanical, electrical and electronic parts. Any one of these components is liable to fail at some time or other. Repair could be done only by a specialist who is able to evaluate the condition of the various parts ranging from cables to connectors, from scintillators to photomultipliers, from microprocessors to microswitches. The knowledge of the intricacies of the various electronic components required for their repairs is quite wide and varied. The electronics industry turns out more and more multi-purpose chips which can carry out the functions of many parts used in the instruments of the earlier generation. This provides protection against unauthorized copying of the circuits but it serves another purpose as well of inhibiting repairs by non-factory personnel. These trends of the instrument design should be taken into consideration when a policy has to be developed for the repairs of the hospital based equipment

  4. Virtual Sensor Test Instrumentation

    Science.gov (United States)

    Wang, Roy

    2011-01-01

    Virtual Sensor Test Instrumentation is based on the concept of smart sensor technology for testing with intelligence needed to perform sell-diagnosis of health, and to participate in a hierarchy of health determination at sensor, process, and system levels. A virtual sensor test instrumentation consists of five elements: (1) a common sensor interface, (2) microprocessor, (3) wireless interface, (4) signal conditioning and ADC/DAC (analog-to-digital conversion/ digital-to-analog conversion), and (5) onboard EEPROM (electrically erasable programmable read-only memory) for metadata storage and executable software to create powerful, scalable, reconfigurable, and reliable embedded and distributed test instruments. In order to maximize the efficient data conversion through the smart sensor node, plug-and-play functionality is required to interface with traditional sensors to enhance their identity and capabilities for data processing and communications. Virtual sensor test instrumentation can be accessible wirelessly via a Network Capable Application Processor (NCAP) or a Smart Transducer Interlace Module (STIM) that may be managed under real-time rule engines for mission-critical applications. The transducer senses the physical quantity being measured and converts it into an electrical signal. The signal is fed to an A/D converter, and is ready for use by the processor to execute functional transformation based on the sensor characteristics stored in a Transducer Electronic Data Sheet (TEDS). Virtual sensor test instrumentation is built upon an open-system architecture with standardized protocol modules/stacks to interface with industry standards and commonly used software. One major benefit for deploying the virtual sensor test instrumentation is the ability, through a plug-and-play common interface, to convert raw sensor data in either analog or digital form, to an IEEE 1451 standard-based smart sensor, which has instructions to program sensors for a wide variety of

  5. Response variance in functional maps: neural darwinism revisited.

    Directory of Open Access Journals (Sweden)

    Hirokazu Takahashi

    Full Text Available The mechanisms by which functional maps and map plasticity contribute to cortical computation remain controversial. Recent studies have revisited the theory of neural Darwinism to interpret the learning-induced map plasticity and neuronal heterogeneity observed in the cortex. Here, we hypothesize that the Darwinian principle provides a substrate to explain the relationship between neuron heterogeneity and cortical functional maps. We demonstrate in the rat auditory cortex that the degree of response variance is closely correlated with the size of its representational area. Further, we show that the response variance within a given population is altered through training. These results suggest that larger representational areas may help to accommodate heterogeneous populations of neurons. Thus, functional maps and map plasticity are likely to play essential roles in Darwinian computation, serving as effective, but not absolutely necessary, structures to generate diverse response properties within a neural population.

  6. Response variance in functional maps: neural darwinism revisited.

    Science.gov (United States)

    Takahashi, Hirokazu; Yokota, Ryo; Kanzaki, Ryohei

    2013-01-01

    The mechanisms by which functional maps and map plasticity contribute to cortical computation remain controversial. Recent studies have revisited the theory of neural Darwinism to interpret the learning-induced map plasticity and neuronal heterogeneity observed in the cortex. Here, we hypothesize that the Darwinian principle provides a substrate to explain the relationship between neuron heterogeneity and cortical functional maps. We demonstrate in the rat auditory cortex that the degree of response variance is closely correlated with the size of its representational area. Further, we show that the response variance within a given population is altered through training. These results suggest that larger representational areas may help to accommodate heterogeneous populations of neurons. Thus, functional maps and map plasticity are likely to play essential roles in Darwinian computation, serving as effective, but not absolutely necessary, structures to generate diverse response properties within a neural population.

  7. Health physics instrumentation needs

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Kenoyer, J.L.

    1984-10-01

    Deficiencies and desirable improvements can be identified in every technical area in which health physics instruments are employed. The needed improvements cover the full spectrum including long-term reliability, human factors, accuracy, ruggedness, ease of calibration, improved radiation response, and improved mixed field response. Some specific areas of deficiency noted along with needed improvements. 17 references

  8. Gender Invariance of the Gambling Behavior Scale for Adolescents (GBS-A): An Analysis of Differential Item Functioning Using Item Response Theory.

    Science.gov (United States)

    Donati, Maria Anna; Chiesi, Francesca; Izzo, Viola A; Primi, Caterina

    2017-01-01

    As there is a lack of evidence attesting the equivalent item functioning across genders for the most employed instruments used to measure pathological gambling in adolescence, the present study was aimed to test the gender invariance of the Gambling Behavior Scale for Adolescents (GBS-A), a new measurement tool to assess the severity of Gambling Disorder (GD) in adolescents. The equivalence of the items across genders was assessed by analyzing Differential Item Functioning within an Item Response Theory framework. The GBS-A was administered to 1,723 adolescents, and the graded response model was employed. The results attested the measurement equivalence of the GBS-A when administered to male and female adolescent gamblers. Overall, findings provided evidence that the GBS-A is an effective measurement tool of the severity of GD in male and female adolescents and that the scale was unbiased and able to relieve truly gender differences. As such, the GBS-A can be profitably used in educational interventions and clinical treatments with young people.

  9. APPLICATION OF THE SPECTROMETRIC METHOD FOR CALCULATING THE DOSE RATE FOR CREATING CALIBRATION HIGHLY SENSITIVE INSTRUMENTS BASED ON SCINTILLATION DETECTION UNITS

    Directory of Open Access Journals (Sweden)

    R. V. Lukashevich

    2017-01-01

    Full Text Available Devices based on scintillation detector are highly sensitive to photon radiation and are widely used to measure the environment dose rate. Modernization of the measuring path to minimize the error in measuring the response of the detector to gamma radiation has already reached its technological ceiling and does not give the proper effect. More promising for this purpose are new methods of processing the obtained spectrometric information. The purpose of this work is the development of highly sensitive instruments based on scintillation detection units using a spectrometric method for calculating dose rate.In this paper we consider the spectrometric method of dosimetry of gamma radiation based on the transformation of the measured instrumental spectrum. Using predetermined or measured functions of the detector response to the action of gamma radiation of a given energy and flux density, a certain function of the energy G(E is determined. Using this function as the core of the integral transformation from the field to dose characteristic, it is possible to obtain the dose value directly from the current instrumentation spectrum. Applying the function G(E to the energy distribution of the fluence of photon radiation in the environment, the total dose rate can be determined without information on the distribution of radioisotopes in the environment.To determine G(E by Monte-Carlo method instrumental response function of the scintillator detector to monoenergetic photon radiation sources as well as other characteristics are calculated. Then the whole full-scale energy range is divided into energy ranges for which the function G(E is calculated using a linear interpolation.Spectrometric method for dose calculation using the function G(E, which allows the use of scintillation detection units for a wide range of dosimetry applications is considered in the article. As well as describes the method of calculating this function by using Monte-Carlo methods

  10. Intercomparison of radiation protection instrumentation in a pulsed neutron field

    Energy Technology Data Exchange (ETDEWEB)

    Caresana, M., E-mail: marco.caresana@polimi.it [Politecnico di Milano, CESNEF, Dipartimento di Energia, via Ponzio 34/3, 20133 Milano (Italy); Denker, A. [Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner-Platz 1, D-14109 Berlin (Germany); Esposito, A. [IFNF-LNF, FISMEL, via E. Fermi 40, 00044 Frascati (Italy); Ferrarini, M. [CNAO, Via Privata Campeggi, 27100 Pavia (Italy); Golnik, N. [Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, Sw. A. Boboli 8, 02-525 Warsaw (Poland); Hohmann, E. [Paul Scherrer Institut (PSI), Radiation Metrology Section, CH-5232 Villigen PSI (Switzerland); Leuschner, A. [Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22603 Hamburg (Germany); Luszik-Bhadra, M. [Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig (Germany); Manessi, G. [CERN, 1211 Geneva 23 (Switzerland); University of Liverpool, Department of Physics, L69 7ZE Liverpool (United Kingdom); Mayer, S. [Paul Scherrer Institut (PSI), Radiation Metrology Section, CH-5232 Villigen PSI (Switzerland); Ott, K. [Helmholtz-Zentrum Berlin, BESSYII, Albert-Einstein-Str.15, 12489 Berlin (Germany); Röhrich, J. [Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner-Platz 1, D-14109 Berlin (Germany); Silari, M. [CERN, 1211 Geneva 23 (Switzerland); Trompier, F. [Institute for Radiological Protection and Nuclear Safety, F-92262 Fontenay aux Roses (France); Volnhals, M.; Wielunski, M. [Helmholtz Zentrum München, Ingolstädter Landstr. 1, D-85764 Neuherberg (Germany)

    2014-02-11

    In the framework of the EURADOS working group 11, an intercomparison of active neutron survey meters was performed in a pulsed neutron field (PNF). The aim of the exercise was to evaluate the performances of various neutron instruments, including commercially available rem-counters, personal dosemeters and instrument prototypes. The measurements took place at the cyclotron of the Helmholtz-Zentrum Berlin für Materialien und Energie GmbH. The cyclotron is routinely used for proton therapy of ocular tumours, but an experimental area is also available. For the therapy the machine accelerates protons to 68 MeV. The interaction of the proton beam with a thick tungsten target produces a neutron field with energy up to about 60 MeV. One interesting feature of the cyclotron is that the beam can be delivered in bursts, with the possibility to modify in a simple and flexible way the burst length and the ion current. Through this possibility one can obtain radiation bursts of variable duration and intensity. All instruments were placed in a reference position and irradiated with neutrons delivered in bursts of different intensity. The analysis of the instrument response as a function of the burst charge (the total electric charge of the protons in the burst shot onto the tungsten target) permitted to assess for each device the dose underestimation due to the time structure of the radiation field. The personal neutron dosemeters were exposed on a standard PMMA slab phantom and the response linearity was evaluated.

  11. Modeling response variation for radiometric calorimeters

    International Nuclear Information System (INIS)

    Mayer, R.L. II.

    1986-01-01

    Radiometric calorimeters are widely used in the DOE complex for accountability measurements of plutonium and tritium. Proper characterization of response variation for these instruments is, therefore, vital for accurate assessment of measurement control as well as for propagation of error calculations. This is not difficult for instruments used to measure items within a narrow range of power values; however, when a single instrument is used to measure items over a wide range of power values, improper estimates of uncertainty can result since traditional error models for radiometric calorimeters assume that uncertainty is not a function of sample power. This paper describes methods which can be used to accurately estimate random response variation for calorimeters used to measure items over a wide range of sample powers. The model is applicable to the two most common modes of calorimeter operation: heater replacement and servo control. 5 refs., 4 figs., 1 tab

  12. Response efficiency during functional communication training: effects of effort on response allocation.

    OpenAIRE

    Richman, D M; Wacker, D P; Winborn, L

    2001-01-01

    An analogue functional analysis revealed that the problem behavior of a young child with developmental delays was maintained by positive reinforcement. A concurrent-schedule procedure was then used to vary the amount of effort required to emit mands. Results suggested that response effort can be an important variable when developing effective functional communication training programs.

  13. Analysis of alpha spectrum instrumental errors accounting for the low energy part of semiconductor detector response function

    International Nuclear Information System (INIS)

    Gurbich, A.F.

    1981-01-01

    A technique for processing of instrumental spectrum of charged particles permitting to take account of a low-energy part of spectrometer line shape, to improve accuracy and to estimate detection efficiency is stated on the example of 226 Ra alpha spectrum. The results obtained show that relative intensities of alpha lines within the limits of statistical errors coincide with the known values, line ''tails'' constituting to 3% of total area of the line. Taking account of ''the line tail'' results in shift of centers of peak gravity by 10-20 keV. So low-energy part of the alpha spectrometer line, which is usually not taken account during spectra processing, markedly affect the results [ru

  14. Radioactive check sources for alpha and beta sensitive radiological instrumentation

    International Nuclear Information System (INIS)

    Barnett, J.M.; Kane, J.E. II.

    1994-06-01

    Since 1991, the Westinghouse Hanford Company has examined the construction and use of alpha and beta radioactive check sources for calibrating instruments and for performing response checks of instruments used for operational and environmental radiation detection. The purpose of using a radioactive check source is to characterize the response of a radiation monitoring instrument in the presence of radioactivity. To accurately calibrate the instrument and check its response, the check source used must emulate as closely as possible the actual physical and isotopic conditions being monitored. The isotope employed and the physical methods used to fabricate the check source (among other factors) determine instrument response. Although information from applicable national and international standards, journal articles, books, and government documents was considered, empirical data collected is most valuable when considering the type of source to use for a particular application. This paper presents source construction methods, use considerations, and standard recommendations. The results of a Hanford Site evaluation of several types of alpha and beta sources are also given

  15. Ocean Optics Instrumentation Systems

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Provides instrumentation suites for a wide variety of measurements to characterize the ocean’s optical environment. These packages have been developed to...

  16. Non-linear signal response functions and their effects on the statistical and noise cancellation properties of isotope ratio measurements by multi-collector plasma mass spectrometry

    International Nuclear Information System (INIS)

    Doherty, W.

    2013-01-01

    A nebulizer-centric response function model of the analytical inductively coupled argon plasma ion source was used to investigate the statistical frequency distributions and noise reduction factors of simultaneously measured flicker noise limited isotope ion signals and their ratios. The response function model was extended by assuming i) a single gaussian distributed random noise source (nebulizer gas pressure fluctuations) and ii) the isotope ion signal response is a parabolic function of the nebulizer gas pressure. Model calculations of ion signal and signal ratio histograms were obtained by applying the statistical method of translation to the non-linear response function model of the plasma. Histograms of Ni, Cu, Pr, Tl and Pb isotope ion signals measured using a multi-collector plasma mass spectrometer were, without exception, negative skew. Histograms of the corresponding isotope ratios of Ni, Cu, Tl and Pb were either positive or negative skew. There was a complete agreement between the measured and model calculated histogram skew properties. The nebulizer-centric response function model was also used to investigate the effect of non-linear response functions on the effectiveness of noise cancellation by signal division. An alternative noise correction procedure suitable for parabolic signal response functions was derived and applied to measurements of isotope ratios of Cu, Ni, Pb and Tl. The largest noise reduction factors were always obtained when the non-linearity of the response functions was taken into account by the isotope ratio calculation. Possible applications of the nebulizer-centric response function model to other types of analytical instrumentation, large amplitude signal noise sources (e.g., lasers, pumped nebulizers) and analytical error in isotope ratio measurements by multi-collector plasma mass spectrometry are discussed. - Highlights: ► Isotope ion signal noise is modelled as a parabolic transform of a gaussian variable. ► Flicker

  17. Measuring Environmental Factors: Unique and Overlapping International Classification of Functioning, Disability and Health Coverage of 5 Instruments.

    Science.gov (United States)

    Heinemann, Allen W; Miskovic, Ana; Semik, Patrick; Wong, Alex; Dashner, Jessica; Baum, Carolyn; Magasi, Susan; Hammel, Joy; Tulsky, David S; Garcia, Sofia F; Jerousek, Sara; Lai, Jin-Shei; Carlozzi, Noelle E; Gray, David B

    2016-12-01

    To describe the unique and overlapping content of the newly developed Environmental Factors Item Banks (EFIB) and 7 legacy environmental factor instruments, and to evaluate the EFIB's construct validity by examining associations with legacy instruments. Cross-sectional, observational cohort. Community. A sample of community-dwelling adults with stroke, spinal cord injury, and traumatic brain injury (N=568). None. EFIB covering domains of the built and natural environment; systems, services, and policies; social environment; and access to information and technology; the Craig Hospital Inventory of Environmental Factors (CHIEF) short form; the Facilitators and Barriers Survey/Mobility (FABS/M) short form; the Home and Community Environment Instrument (HACE); the Measure of the Quality of the Environment (MQE) short form; and 3 of the Patient Reported Outcomes Measurement Information System's (PROMIS) Quality of Social Support measures. The EFIB and legacy instruments assess most of the International Classification of Functioning, Disability and Health (ICF) environmental factors chapters, including chapter 1 (products and technology; 75 items corresponding to 11 codes), chapter 2 (natural environment and human-made changes; 31 items corresponding to 7 codes), chapter 3 (support and relationships; 74 items corresponding to 7 codes), chapter 4 (attitudes; 83 items corresponding to 8 codes), and chapter 5 (services, systems, and policies; 72 items corresponding to 16 codes). Construct validity is provided by moderate correlations between EFIB measures and the CHIEF, MQE barriers, HACE technology mobility, FABS/M community built features, and PROMIS item banks and by small correlations with other legacy instruments. Only 5 of the 66 legacy instrument correlation coefficients are moderate, suggesting they measure unique aspects of the environment, whereas all intra-EFIB correlations were at least moderate. The EFIB measures provide a brief and focused assessment of ICF

  18. Maturation of Sensori-Motor Functional Responses in the Preterm Brain.

    Science.gov (United States)

    Allievi, Alessandro G; Arichi, Tomoki; Tusor, Nora; Kimpton, Jessica; Arulkumaran, Sophie; Counsell, Serena J; Edwards, A David; Burdet, Etienne

    2016-01-01

    Preterm birth engenders an increased risk of conditions like cerebral palsy and therefore this time may be crucial for the brain's developing sensori-motor system. However, little is known about how cortical sensori-motor function matures at this time, whether development is influenced by experience, and about its role in spontaneous motor behavior. We aimed to systematically characterize spatial and temporal maturation of sensori-motor functional brain activity across this period using functional MRI and a custom-made robotic stimulation device. We studied 57 infants aged from 30 + 2 to 43 + 2 weeks postmenstrual age. Following both induced and spontaneous right wrist movements, we saw consistent positive blood oxygen level-dependent functional responses in the contralateral (left) primary somatosensory and motor cortices. In addition, we saw a maturational trend toward faster, higher amplitude, and more spatially dispersed functional responses; and increasing integration of the ipsilateral hemisphere and sensori-motor associative areas. We also found that interhemispheric functional connectivity was significantly related to ex-utero exposure, suggesting the influence of experience-dependent mechanisms. At term equivalent age, we saw a decrease in both response amplitude and interhemispheric functional connectivity, and an increase in spatial specificity, culminating in the establishment of a sensori-motor functional response similar to that seen in adults. © The Author 2015. Published by Oxford University Press.

  19. Functional Roles of Syk in Macrophage-Mediated Inflammatory Responses

    Science.gov (United States)

    Yi, Young-Su; Son, Young-Jin; Ryou, Chongsuk; Sung, Gi-Ho; Kim, Jong-Hoon; Cho, Jae Youl

    2014-01-01

    Inflammation is a series of complex biological responses to protect the host from pathogen invasion. Chronic inflammation is considered a major cause of diseases, such as various types of inflammatory/autoimmune diseases and cancers. Spleen tyrosine kinase (Syk) was initially found to be highly expressed in hematopoietic cells and has been known to play crucial roles in adaptive immune responses. However, recent studies have reported that Syk is also involved in other biological functions, especially in innate immune responses. Although Syk has been extensively studied in adaptive immune responses, numerous studies have recently presented evidence that Syk has critical functions in macrophage-mediated inflammatory responses and is closely related to innate immune response. This review describes the characteristics of Syk-mediated signaling pathways, summarizes the recent findings supporting the crucial roles of Syk in macrophage-mediated inflammatory responses and diseases, and discusses Syk-targeted drug development for the therapy of inflammatory diseases. PMID:25045209

  20. Functional Roles of Syk in Macrophage-Mediated Inflammatory Responses

    Directory of Open Access Journals (Sweden)

    Young-Su Yi

    2014-01-01

    Full Text Available Inflammation is a series of complex biological responses to protect the host from pathogen invasion. Chronic inflammation is considered a major cause of diseases, such as various types of inflammatory/autoimmune diseases and cancers. Spleen tyrosine kinase (Syk was initially found to be highly expressed in hematopoietic cells and has been known to play crucial roles in adaptive immune responses. However, recent studies have reported that Syk is also involved in other biological functions, especially in innate immune responses. Although Syk has been extensively studied in adaptive immune responses, numerous studies have recently presented evidence that Syk has critical functions in macrophage-mediated inflammatory responses and is closely related to innate immune response. This review describes the characteristics of Syk-mediated signaling pathways, summarizes the recent findings supporting the crucial roles of Syk in macrophage-mediated inflammatory responses and diseases, and discusses Syk-targeted drug development for the therapy of inflammatory diseases.

  1. Assessing health status and quality-of-life instruments: attributes and review criteria.

    Science.gov (United States)

    Aaronson, Neil; Alonso, Jordi; Burnam, Audrey; Lohr, Kathleen N; Patrick, Donald L; Perrin, Edward; Stein, Ruth E

    2002-05-01

    The field of health status and quality of life (QoL) measurement - as a formal discipline with a cohesive theoretical framework, accepted methods, and diverse applications--has been evolving for the better part of 30 years. To identify health status and QoL instruments and review them against rigorous criteria as a precursor to creating an instrument library for later dissemination, the Medical Outcomes Trust in 1994 created an independently functioning Scientific Advisory Committee (SAC). In the mid-1990s, the SAC defined a set of attributes and criteria to carry out instrument assessments; 5 years later, it updated and revised these materials to take account of the expanding theories and technologies upon which such instruments were being developed. This paper offers the SAC's current conceptualization of eight key attributes of health status and QoL instruments (i.e., conceptual and measurement model; reliability; validity; responsiveness; interpretability; respondent and administrative burden; alternate forms; and cultural and language adaptations) and the criteria by which instruments would be reviewed on each of those attributes. These are suggested guidelines for the field to consider and debate; as measurement techniques become both more familiar and more sophisticated, we expect that experts will wish to update and refine these criteria accordingly.

  2. Functions and Requirements for Automated Liquid Level Gauge Instruments in Single-Shell and Double-Shell Tank Farms

    International Nuclear Information System (INIS)

    CARPENTER, K.E.

    1999-01-01

    This functions and requirements document defines the baseline requirements and criteria for the design, purchase, fabrication, construction, installation, and operation of automated liquid level gauge instruments in the Tank Farms. This document is intended to become the technical baseline for current and future installation, operation and maintenance of automated liquid level gauges in single-shell and double-shell tank farms

  3. Instrumentation for the follow-up of severe accidents

    International Nuclear Information System (INIS)

    Munoz Sanchez, A.; Nino Perote, R.

    2000-01-01

    During severe accidents, it is foreseeable that the instrumentation installed in a plant is subjected to conditions which are more hostile than those for which the instrumentation was designed and qualified. Moreover, new, specific instrumentation is required to monitor variables which have not been considered until now, and to control systems which lessen the consequences of severe accidents. Both existing instrumentation used to monitor critical functions in design basis accident conditions and additional instrumentation which provides the information necessary to control and mitigate the consequences of severe accidents, have to be designed to withstand such conditions, especially in terms of measurements range, functional characteristics and qualification to withstand pressure and temperature loads resulting from steam explosion, hydrogen combustion/explosion and high levels of radiation over long periods of time. (Author)

  4. Avoidance-based human Pavlovian-to-instrumental transfer

    Science.gov (United States)

    Lewis, Andrea H.; Niznikiewicz, Michael A.; Delamater, Andrew R.; Delgado, Mauricio R.

    2013-01-01

    The Pavlovian-to-instrumental transfer (PIT) paradigm probes the influence of Pavlovian cues over instrumentally learned behavior. The paradigm has been used extensively to probe basic cognitive and motivational processes in studies of animal learning but, more recently, PIT and its underlying neural basis have been extended to investigations in humans. These initial neuroimaging studies of PIT have focused on the influence of appetitively conditioned stimuli on instrumental responses maintained by positive reinforcement, and highlight the involvement of the striatum. In the current study, we sought to understand the neural correlates of PIT in an aversive Pavlovian learning situation when instrumental responding was maintained through negative reinforcement. Participants exhibited specific PIT, wherein selective increases in instrumental responding to conditioned stimuli occurred when the stimulus signaled a specific aversive outcome whose omission negatively reinforced the instrumental response. Additionally, a general PIT effect was observed such that when a stimulus was associated with a different aversive outcome than was used to negatively reinforce instrumental behavior, the presence of that stimulus caused a non-selective increase in overall instrumental responding. Both specific and general PIT behavioral effects correlated with increased activation in corticostriatal circuitry, particularly in the striatum, a region involved in cognitive and motivational processes. These results suggest that avoidance-based PIT utilizes a similar neural mechanism to that seen with PIT in an appetitive context, which has implications for understanding mechanisms of drug-seeking behavior during addiction and relapse. PMID:24118624

  5. A damage detection method for instrumented civil structures using prerecorded Green’s functions and cross-correlation

    OpenAIRE

    Heckman, Vanessa; Kohler, Monica; Heaton, Thomas

    2011-01-01

    Automated damage detection methods have application to instrumented structures that are susceptible to types of damage that are difficult or costly to detect. The presented method has application to the detection of brittle fracture of welded beam-column connections in steel moment-resisting frames (MRFs), where locations of potential structural damage are known a priori. The method makes use of a prerecorded catalog of Green’s function templates and a cross-correlation method ...

  6. Conceptual DFT: the chemical relevance of higher response functions.

    Science.gov (United States)

    Geerlings, P; De Proft, F

    2008-06-07

    In recent years conceptual density functional theory offered a perspective for the interpretation/prediction of experimental/theoretical reactivity data on the basis of a series of response functions to perturbations in the number of electrons and/or external potential. This approach has enabled the sharp definition and computation, from first principles, of a series of well-known but sometimes vaguely defined chemical concepts such as electronegativity and hardness. In this contribution, a short overview of the shortcomings of the simplest, first order response functions is illustrated leading to a description of chemical bonding in a covalent interaction in terms of interacting atoms or groups, governed by electrostatics with the tendency to polarize bonds on the basis of electronegativity differences. The second order approach, well known until now, introduces the hardness/softness and Fukui function concepts related to polarizability and frontier MO theory, respectively. The introduction of polarizability/softness is also considered in a historical perspective in which polarizability was, with some exceptions, mainly put forward in non covalent interactions. A particular series of response functions, arising when the changes in the external potential are solely provoked by changes in nuclear configurations (the "R-analogues") are also systematically considered. The main part of the contribution is devoted to third order response functions which, at first sight, may be expected not to yield chemically significant information, as turns out to be for the hyperhardness. A counterexample is the dual descriptor and its R analogue, the initial hardness response, which turns out to yield a firm basis to regain the Woodward-Hoffmann rules for pericyclic reactions based on a density-only basis, i.e. without involving the phase, sign, symmetry of the wavefunction. Even the second order nonlinear response functions are shown possibly to bear interesting information, e

  7. The instrumentation of fast reactor

    International Nuclear Information System (INIS)

    Endo, Akira

    2003-03-01

    The author has been engaged in the development of fast reactors over the last 30 years with both an involvement with the early technology development on the experimental breeder reactor Joyo, and latterly continuing this work on the prototype breeder reactor, Monju. In order to pass on this experience to younger engineers this paper is produced to outline this experience in the sincere hope that the information given will be utilised in future educational training material. The paper discusses the wide diversity on the associated instrument technology which the fast breeder reactor requires. The first chapter outlines the fast reactor system, followed by discussions on reactor instrumentation, measurement principles, temperature dependencies, and verification response characteristics from various viewpoints, are discussed in chapters two and three. The important issues of failed fuel location detection, and sodium leak detection from steam generators are discussed in chapters 4 and 5 respectively. Appended to this report is an explanation on the methods of measuring response characteristics on instrumentation systems using error analysis, random signal theory and measuring method of response characteristic by AR (autoregressive) model on which it appears is becoming an indispensable problem for persons involved with this technology in the future. (author)

  8. Instrumental traditions and theories of light the uses of instruments in the optical revolution

    CERN Document Server

    Chen, Xiang

    2000-01-01

    An analysis of the optical revolution in the context of early 19th century Britain. Far from merely involving the replacement of one optical theory by another, the revolution also involved substantial changes in instruments and the practices that surrounded them. People's judgements about classification, explanation and evaluation were affected by the way they used such optical instruments as spectroscopes, telescopes, polarisers, photometers, gratings, prisms and apertures. There were two instrumental traditions in this historical period, each of which nurtured a body of practice that exemplified how optical instruments should be operated, and especially how the eye should be used. These traditions functioned just like paradigms, shaping perspectives and even world views. Readership: Scholars and graduate students in the history of science, history of instrument, philosophy of science and science studies. Can also be used as a textbook in graduate courses on 19th century physics.

  9. Adaptive Feeding behavior and functional responses in pelagic copepods

    DEFF Research Database (Denmark)

    Kiørboe, Thomas; Saiz, Enrico; Tiselius, Peter

    2018-01-01

    Zooplankton may modify their feeding behavior in response to prey availability and presence of predators with implications to populations of both predators and prey. Optimal foraging theory predicts that such responses result in a type II functional response for passive foragers and a type III re...

  10. The instrument control unit of SPICA SAFARI: a macro-unit to host all the digital control functionalities of the spectrometer

    Science.gov (United States)

    Di Giorgio, Anna Maria; Biondi, David; Saggin, Bortolino; Shatalina, Irina; Viterbini, Maurizio; Giusi, Giovanni; Liu, Scige J.; Cerulli-Irelli, Paquale; Van Loon, Dennis; Cara, Christophe

    2012-09-01

    We present the preliminary design of the Instrument Control Unit (ICU) of the SpicA FAR infrared Instrument (SAFARI), an imaging Fourier Transform Spectrometer (FTS) designed to give continuous wavelength coverage in both photometric and spectroscopic modes from around 34 to 210 µm. Due to the stringent requirements in terms of mass and volume, the overall SAFARI warm electronics will be composed by only two main units: Detector Control Unit and ICU. ICU is therefore a macro-unit incorporating the four digital sub-units dedicated to the control of the overall instrument functionalities: the Cooler Control Unit, the Mechanism Control Unit, the Digital processing Unit and the Power Supply Unit. Both the mechanical solution adopted to host the four sub-units and the internal electrical architecture are presented as well as the adopted redundancy approach.

  11. Intelligent type sodium instrumentations for LMFBR

    International Nuclear Information System (INIS)

    Chen Daolong

    1996-07-01

    The constructions and performances of lots of newly developed intelligent type sodium instrumentations are described. The graduation characteristic equations for corresponding transducer using the medium temperature as the parameter are given. These intelligent type sodium instrumentations are possessed of good linearity. The accurate measurement data of sodium process parameters (flowrate, pressure and level) can be obtained by means of their on-line compensation function of the temperature effect. Moreover, these intelligent type sodium instrumentations are possessed of the self-inspection, the electric shutoff protection, the setting of full-scale, the setting of alarm limits (two upper limits and two lower limits alarms), the thermocouple breaking alarm, mutual isolative the 0∼10 V direct-current analogue output and the CENTRONICS standard digital output, and the alarm relay contact output. Theses intelligent type sodium instrumentations are suitable particularly for the instrument, control and protective systems of LMFBR by means of these excellent functions based on microprocessor. The basic errors of the intelligent type sodium flowmeter, immersed sodium flowmeter, sodium manometer and sodium level gauge are +-2%, +-2.3%, +-0.3% and +-1.9% of measuring ranges respectively. (9 figs.)

  12. Science in Emergency Response at CDC: Structure and Functions.

    Science.gov (United States)

    Iskander, John; Rose, Dale A; Ghiya, Neelam D

    2017-09-01

    Recent high-profile activations of the US Centers for Disease Control and Prevention (CDC) Emergency Operations Center (EOC) include responses to the West African Ebola and Zika virus epidemics. Within the EOC, emergency responses are organized according to the Incident Management System, which provides a standardized structure and chain of command, regardless of whether the EOC activation occurs in response to an outbreak, natural disaster, or other type of public health emergency. By embedding key scientific roles, such as the associate director for science, and functions within a Scientific Response Section, the current CDC emergency response structure ensures that both urgent and important science issues receive needed attention. Key functions during emergency responses include internal coordination of scientific work, data management, information dissemination, and scientific publication. We describe a case example involving the ongoing Zika virus response that demonstrates how the scientific response structure can be used to rapidly produce high-quality science needed to answer urgent public health questions and guide policy. Within the context of emergency response, longer-term priorities at CDC include both streamlining administrative requirements and funding mechanisms for scientific research.

  13. Linear density response function in the projector augmented wave method

    DEFF Research Database (Denmark)

    Yan, Jun; Mortensen, Jens Jørgen; Jacobsen, Karsten Wedel

    2011-01-01

    We present an implementation of the linear density response function within the projector-augmented wave method with applications to the linear optical and dielectric properties of both solids, surfaces, and interfaces. The response function is represented in plane waves while the single...... functions of Si, C, SiC, AlP, and GaAs compare well with previous calculations. While optical properties of semiconductors, in particular excitonic effects, are generally not well described by ALDA, we obtain excellent agreement with experiments for the surface loss function of graphene and the Mg(0001...

  14. Instrument validation system of general application

    International Nuclear Information System (INIS)

    Filshtein, E.L.

    1990-01-01

    This paper describes the Instrument Validation System (IVS) as a software system which has the capability of evaluating the performance of a set of functionally related instrument channels to identify failed instruments and to quantify instrument drift. Under funding from Combustion Engineering (C-E), the IVS has been developed to the extent that a computer program exists whose use has been demonstrated. The initial development work shows promise for success and for wide application, not only to power plants, but also to industrial manufacturing and process control. Applications in the aerospace and military sector are also likely

  15. Instrument performance and simulation verification of the POLAR detector

    Science.gov (United States)

    Kole, M.; Li, Z. H.; Produit, N.; Tymieniecka, T.; Zhang, J.; Zwolinska, A.; Bao, T. W.; Bernasconi, T.; Cadoux, F.; Feng, M. Z.; Gauvin, N.; Hajdas, W.; Kong, S. W.; Li, H. C.; Li, L.; Liu, X.; Marcinkowski, R.; Orsi, S.; Pohl, M.; Rybka, D.; Sun, J. C.; Song, L. M.; Szabelski, J.; Wang, R. J.; Wang, Y. H.; Wen, X.; Wu, B. B.; Wu, X.; Xiao, H. L.; Xiong, S. L.; Zhang, L.; Zhang, L. Y.; Zhang, S. N.; Zhang, X. F.; Zhang, Y. J.; Zhao, Y.

    2017-11-01

    POLAR is a new satellite-born detector aiming to measure the polarization of an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of September 2016, is designed to measure the polarization of the hard X-ray flux by measuring the distribution of the azimuthal scattering angles of the incoming photons. A detailed understanding of the polarimeter and specifically of the systematic effects induced by the instrument's non-uniformity are required for this purpose. In order to study the instrument's response to polarization, POLAR underwent a beam test at the European Synchrotron Radiation Facility in France. In this paper both the beam test and the instrument performance will be described. This is followed by an overview of the Monte Carlo simulation tools developed for the instrument. Finally a comparison of the measured and simulated instrument performance will be provided and the instrument response to polarization will be presented.

  16. 32 CFR 352a.4 - Responsibilities and functions.

    Science.gov (United States)

    2010-07-01

    ...) ORGANIZATIONAL CHARTERS DEFENSE FINANCE AND ACCOUNTING SERVICE (DFAS) § 352a.4 Responsibilities and functions. (a) The Director, Defense Finance and Accounting Service (DFAS), is the principal DoD executive for finance and accounting requirements, systems, and functions identified in DoD Directive 5118.3, 1 and...

  17. The functional response of a generalist predator.

    Directory of Open Access Journals (Sweden)

    Sophie Smout

    Full Text Available BACKGROUND: Predators can have profound impacts on the dynamics of their prey that depend on how predator consumption is affected by prey density (the predator's functional response. Consumption by a generalist predator is expected to depend on the densities of all its major prey species (its multispecies functional response, or MSFR, but most studies of generalists have focussed on their functional response to only one prey species. METHODOLOGY AND PRINCIPAL FINDINGS: Using Bayesian methods, we fit an MSFR to field data from an avian predator (the hen harrier Circus cyaneus feeding on three different prey species. We use a simple graphical approach to show that ignoring the effects of alternative prey can give a misleading impression of the predator's effect on the prey of interest. For example, in our system, a "predator pit" for one prey species only occurs when the availability of other prey species is low. CONCLUSIONS AND SIGNIFICANCE: The Bayesian approach is effective in fitting the MSFR model to field data. It allows flexibility in modelling over-dispersion, incorporates additional biological information into the parameter priors, and generates estimates of uncertainty in the model's predictions. These features of robustness and data efficiency make our approach ideal for the study of long-lived predators, for which data may be sparse and management/conservation priorities pressing.

  18. STRUCTURAL AND FUNCTIONAL MODEL OF FORMING FUTURE MUSIC TEACHER’S CREATIVE THINKING IN INSTRUMENTAL AND PERFORMING TRAINING

    Directory of Open Access Journals (Sweden)

    Nadiia Lavrentieva

    2016-11-01

    Full Text Available In the article conceptual bases of forming students’ creative thinking in the instrumental and performing activities are revealed, taking current training trends into account. The contradictions between the requirements of society to create favorable conditions to realize future music teachers’ creative potential and current directions of a higher educational establishment to ‘a result”, which causes a specific system of promotion and support students’ value orientations and encourages students to master existing knowledge, algorithms, and performing models, depict the relevant problems of making out the system of the future music teachers’ instrumental and performing training that is aimed at developing their creative thinking. It is noted that while defining such phenomena as creative thinking and cognitive work a great number of scientists emphasizes on the word “create” which means finding and creating something that hasn’t been found in the previous individual or social experience. The aim of the article is to disclose the content and stages of implementing structural and functional model of forming future music teachers’ creative thinking The model is formed as an alternative to information and reproductive approach to training future specialists. The concept model is based on the target of forming future music teachers’ creative and methodological thinking, professional competence, activity and approaches to the students’ training to complete fulfillment of modern needs of professional and music education. The author specifies criteria of structural model of future music teachers’ creative thinking. They are value and motivational, cognitive and educational, action and technological, creative and modulating ones The effectiveness of the future music teachers’ creative thinking in instrumental and performing training depends on the level of forming clear science-based system that has a certain conceptual

  19. Computations of nuclear response functions with MACK-IV

    International Nuclear Information System (INIS)

    Abdou, M.A.; Gohar, Y.

    1978-01-01

    The MACK computer program calculates energy pointwise and multigroup nuclear response functions from basic nuclear data in ENDF/B format. The new version of the program, MACK-IV, incorporates major developments and improvements aimed at maximizing the utilization of available nuclear data and ensuring energy conservation in nuclear heating calculations. A new library, MACKLIB-IV, of nuclear response functions was generated in the CTR energy group structure of 171 neutron groups and 36 gamma groups. The library was prepared using MACK-IV and ENDF/B-IV and is suitable for fusion, fusion-fission hybrids, and fission applications

  20. Computations of nuclear response functions with MACK-IV

    Energy Technology Data Exchange (ETDEWEB)

    Abdou, M A; Gohar, Y

    1978-01-01

    The MACK computer program calculates energy pointwise and multigroup nuclear response functions from basic nuclear data in ENDF/B format. The new version of the program, MACK-IV, incorporates major developments and improvements aimed at maximizing the utilization of available nuclear data and ensuring energy conservation in nuclear heating calculations. A new library, MACKLIB-IV, of nuclear response functions was generated in the CTR energy group structure of 171 neutron groups and 36 gamma groups. The library was prepared using MACK-IV and ENDF/B-IV and is suitable for fusion, fusion-fission hybrids, and fission applications.

  1. Monitoring Instrument Performance in Regional Broadband Seismic Network Using Ambient Seismic Noise

    Science.gov (United States)

    Ye, F.; Lyu, S.; Lin, J.

    2017-12-01

    In the past ten years, the number of seismic stations has increased significantly, and regional seismic networks with advanced technology have been gradually developed all over the world. The resulting broadband data help to improve the seismological research. It is important to monitor the performance of broadband instruments in a new network in a long period of time to ensure the accuracy of seismic records. Here, we propose a method that uses ambient noise data in the period range 5-25 s to monitor instrument performance and check data quality in situ. The method is based on an analysis of amplitude and phase index parameters calculated from pairwise cross-correlations of three stations, which provides multiple references for reliable error estimates. Index parameters calculated daily during a two-year observation period are evaluated to identify stations with instrument response errors in near real time. During data processing, initial instrument responses are used in place of available instrument responses to simulate instrument response errors, which are then used to verify our results. We also examine feasibility of the tailing noise using data from stations selected from USArray in different locations and analyze the possible instrumental errors resulting in time-shifts used to verify the method. Additionally, we show an application that effects of instrument response errors that experience pole-zeros variations on monitoring temporal variations in crustal properties appear statistically significant velocity perturbation larger than the standard deviation. The results indicate that monitoring seismic instrument performance helps eliminate data pollution before analysis begins.

  2. Evaluation of the detector response function digital conventional radiology

    International Nuclear Information System (INIS)

    Arino Gil, A.; Hernandez Rodriguez, J.; Mateos Salvador, P.; Rodriguez Lopez, B.; Font Gelabert, J. C.

    2013-01-01

    The objective of this work is to obtain the response function that relates the air kerma at the entrance of the detector and pixel value, for a series of digital detectors of conventional Radiology model Optimus DigitalDiagnost Philips () and 6000 Definium General Electric. From the set of measurements is obtained a response function for each reference type of detector, and compared with those published in the literature for these teams. (Author)

  3. Recent applications of microprocessor-based instruments in nuclear power stations

    International Nuclear Information System (INIS)

    Cash, N.R.; Dennis, U.E.

    1988-01-01

    The incorporation of microprocessors in the design of nuclear power plant instrumentation has led to levels of measurement and control not available previously. In addition to the expected expansion of functional (system) capability, numerous desirable features now are possible. The added ability to both self-calibrate and perform compensation algorithms has led to dramatic improvements in accuracies, response times, and noise rejection. Automated performance checking and self-testing simplify troubleshooting and required periodic surveillance. Alphanumeric displays allow both menu-driven operation and user-prompting, which, in turn, contribute to mistake avoidance. New features of these microprocessor-based instruments are of specific benefit in nuclear power reactors, were safety is of prime concern. Greater reliability and accuracy can be provided. Shortened calibration, surveillance, and repair times reduce the exposure to unnecessary challenges of the plant's protection systems that can arise from spurious noise signals

  4. Design requirements for the SWIFT instrument

    International Nuclear Information System (INIS)

    Rahnama, P; McDade, I; Shepherd, G; Gault, W

    2013-01-01

    The Stratospheric Wind Interferometer for Transport studies (SWIFT) instrument is a proposed limb-viewing satellite instrument that employs the method of Doppler Michelson interferometry to measure stratospheric wind velocities and ozone densities in the altitude range of 15–45 km. The values of the main instrument parameters including filter system parameters and Michelson interferometer parameters are derived using simulations and analyses. The system design requirements for the instrument and spacecraft are presented and discussed. Some of the retrieval-imposed design requirements are also discussed. Critical design issues are identified. The design optimization process is described. The sensitivity of wind measurements to instrument characteristics is investigated including the impact on critical design issues. Using sensitivity analyses, the instrument parameters were iteratively optimized in order to meet the science objectives. It is shown that wind measurements are sensitive to the thermal sensitivity of the instrument components, especially the narrow filter and the Michelson interferometer. The optimized values of the main system parameters including Michelson interferometer optical path difference, instrument visibility, instrument responsivity and knowledge of spacecraft velocity are reported. This work also shows that the filter thermal drift and the Michelson thermal drift are two main technical risks. (paper)

  5. ARES: automated response function code. Users manual. [HPGAM and LSQVM

    Energy Technology Data Exchange (ETDEWEB)

    Maung, T.; Reynolds, G.M.

    1981-06-01

    This ARES user's manual provides detailed instructions for a general understanding of the Automated Response Function Code and gives step by step instructions for using the complete code package on a HP-1000 system. This code is designed to calculate response functions of NaI gamma-ray detectors, with cylindrical or rectangular geometries.

  6. MHTGR steam generator on-line heat balance, instrumentation and function

    International Nuclear Information System (INIS)

    Klapka, R.E.; Howard, W.W.; Etzel, K.T.; Basol, M.; Karim, N.U.

    1991-09-01

    Instrumentation is used to measure the Modular High Temperature Gas-Cooled Reactor (MHTGR) steam generator dissimilar metal weld temperature during start-up testing. Additional instrumentation is used to determine an on-line heat balance which is maintained during the 40 year module life. In the process of calibrating the on-line heat balance, the helium flow is adjusted to yield the optimum boiling level in the steam generator relative to the dissimilar metal weld. After calibration is complete the weld temperature measurement is non longer required. The reduced boiling level range results in less restrictive steam generator design constraints

  7. A Non-Parametric Item Response Theory Evaluation of the CAGE Instrument Among Older Adults.

    Science.gov (United States)

    Abdin, Edimansyah; Sagayadevan, Vathsala; Vaingankar, Janhavi Ajit; Picco, Louisa; Chong, Siow Ann; Subramaniam, Mythily

    2018-02-23

    The validity of the CAGE using item response theory (IRT) has not yet been examined in older adult population. This study aims to investigate the psychometric properties of the CAGE using both non-parametric and parametric IRT models, assess whether there is any differential item functioning (DIF) by age, gender and ethnicity and examine the measurement precision at the cut-off scores. We used data from the Well-being of the Singapore Elderly study to conduct Mokken scaling analysis (MSA), dichotomous Rasch and 2-parameter logistic IRT models. The measurement precision at the cut-off scores were evaluated using classification accuracy (CA) and classification consistency (CC). The MSA showed the overall scalability H index was 0.459, indicating a medium performing instrument. All items were found to be homogenous, measuring the same construct and able to discriminate well between respondents with high levels of the construct and the ones with lower levels. The item discrimination ranged from 1.07 to 6.73 while the item difficulty ranged from 0.33 to 2.80. Significant DIF was found for 2-item across ethnic group. More than 90% (CC and CA ranged from 92.5% to 94.3%) of the respondents were consistently and accurately classified by the CAGE cut-off scores of 2 and 3. The current study provides new evidence on the validity of the CAGE from the IRT perspective. This study provides valuable information of each item in the assessment of the overall severity of alcohol problem and the precision of the cut-off scores in older adult population.

  8. Functional neural networks underlying response inhibition in adolescents and adults.

    Science.gov (United States)

    Stevens, Michael C; Kiehl, Kent A; Pearlson, Godfrey D; Calhoun, Vince D

    2007-07-19

    This study provides the first description of neural network dynamics associated with response inhibition in healthy adolescents and adults. Functional and effective connectivity analyses of whole brain hemodynamic activity elicited during performance of a Go/No-Go task were used to identify functionally integrated neural networks and characterize their causal interactions. Three response inhibition circuits formed a hierarchical, inter-dependent system wherein thalamic modulation of input to premotor cortex by fronto-striatal regions led to response suppression. Adolescents differed from adults in the degree of network engagement, regional fronto-striatal-thalamic connectivity, and network dynamics. We identify and characterize several age-related differences in the function of neural circuits that are associated with behavioral performance changes across adolescent development.

  9. The Caregiver Contribution to Heart Failure Self-Care (CACHS): Further Psychometric Testing of a Novel Instrument.

    Science.gov (United States)

    Buck, Harleah G; Harkness, Karen; Ali, Muhammad Usman; Carroll, Sandra L; Kryworuchko, Jennifer; McGillion, Michael

    2017-04-01

    Caregivers (CGs) contribute important assistance with heart failure (HF) self-care, including daily maintenance, symptom monitoring, and management. Until CGs' contributions to self-care can be quantified, it is impossible to characterize it, account for its impact on patient outcomes, or perform meaningful cost analyses. The purpose of this study was to conduct psychometric testing and item reduction on the recently developed 34-item Caregiver Contribution to Heart Failure Self-care (CACHS) instrument using classical and item response theory methods. Fifty CGs (mean age 63 years ±12.84; 70% female) recruited from a HF clinic completed the CACHS in 2014 and results evaluated using classical test theory and item response theory. Items would be deleted for low (.95) endorsement, low (.7) corrected item-total correlations, significant pairwise correlation coefficients, floor or ceiling effects, relatively low latent trait and item information function levels ( .5), and differential item functioning. After analysis, 14 items were excluded, resulting in a 20-item instrument (self-care maintenance eight items; monitoring seven items; and management five items). Most items demonstrated moderate to high discrimination (median 2.13, minimum .77, maximum 5.05), and appropriate item difficulty (-2.7 to 1.4). Internal consistency reliability was excellent (Cronbach α = .94, average inter-item correlation = .41) with no ceiling effects. The newly developed 20-item version of the CACHS is supported by rigorous instrument development and represents a novel instrument to measure CGs' contribution to HF self-care. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. LOFT instrumented fuel design and operating experience

    International Nuclear Information System (INIS)

    Russell, M.L.

    1979-01-01

    A summary description of the Loss-of-Fluid Test (LOFT) system instrumented core construction details and operating experience through reactor startup and loss-of-coolant experiment (LOCE) operations performed to date are discussed. The discussion includes details of the test instrumentation attachment to the fuel assembly, the structural response of the fuel modules to the forces generated by a double-ended break of a pressurized water reactor (PWR) coolant pipe at the inlet to the reactor vessel, the durability of the LOFT fuel and test instrumentation, and the plans for incorporation of improved fuel assembly test instrumentation features in the LOFT core

  11. Technical Training seminar: Texas Instruments

    CERN Multimedia

    2006-01-01

    Monday 6 November TECHNICAL TRAINING SEMINAR 14:00 to 17:30 - Training Centre Auditorium (bldg. 593) Texas Instruments Technical Seminar Michael Scholtholt, Field Application Engineer / TEXAS INSTRUMENTS (US, D, CH) POWER - A short approach to Texas Instruments power products Voltage mode vs. current mode control Differentiating DC/DC converters by analyzing control and compensation schemes: line / load regulation, transient response, BOM, board space, ease-of-use Introduction to the SWIFT software FPGA + CPLD power solutions WIRELESS / CHIPCON Decision criteria when choosing a RF platform Introduction to Texas Instruments wireless products: standardized platforms proprietary platforms ( 2.4 GHz / sub 1 GHz) development tools Antenna design: example for 2.4 GHz questions, discussion Industrial partners: Robert Medioni, François Caloz / Spoerle Electronic, CH-1440 Montagny (VD), Switzerland Phone: +41 24 447 0137, email: RMedioni@spoerle.com, http://www.spoerle.com Language: English. Free s...

  12. The Infrared Camera for RATIR, a Rapid Response GRB Followup Instrument

    Science.gov (United States)

    Rapchun, David A.; Alardin, W.; Bigelow, B. C.; Bloom, J.; Butler, N.; Farah, A.; Fox, O. D.; Gehrels, N.; Gonzalez, J.; Klein, C.; Kutyrev, A. S.; Lotkin, G.; Morisset, C.; Moseley, S. H.; Richer, M.; Robinson, F. D.; Samuel, M. V.; Sparr, L. M.; Tucker, C.; Watson, A.

    2011-01-01

    RATIR (Reionization and Transients Infrared instrument) will be a hybrid optical/near IR imager that will utilize the "J-band dropout" to rapidly identify very high redshift (VHR) gamma-ray bursts (GRBs) from a sample of all observable Swift bursts. Our group at GSFC is developing the instrument in collaboration with UC Berkeley (UCB) and University of Mexico (UNAM). RATIR has both a visible and IR camera, which give it access to 8 bands spanning visible and IR wavelengths. The instrument implements a combination of filters and dichroics to provide the capability of performing photometry in 4 bands simultaneously. The GSFC group leads the design and construction of the instrument's IR camera, equipped with two HgCdTe 2k x 2k Teledyne detectors. The cryostat housing these detectors is cooled by a mechanical cryo-compressor, which allows uninterrupted operation on the telescope. The host 1.5-m telescope, located at the UNAM San Pedro Martir Observatory, Mexico, has recently undergone robotization, allowing for fully automated, continuous operation. After commissioning in the spring of 2011, RATIR will dedicate its time to obtaining prompt follow-up observations of GRBs and identifying VHR GRBs, thereby providing a valuable tool for studying the epoch of reionization.

  13. Diagnostics for Linear Models With Functional Responses

    OpenAIRE

    Xu, Hongquan; Shen, Qing

    2005-01-01

    Linear models where the response is a function and the predictors are vectors are useful in analyzing data from designed experiments and other situations with functional observations. Residual analysis and diagnostics are considered for such models. Studentized residuals are defined and their properties are studied. Chi-square quantile-quantile plots are proposed to check the assumption of Gaussian error process and outliers. Jackknife residuals and an associated test are proposed to det...

  14. Method and apparatus for continuous fluid leak monitoring and detection in analytical instruments and instrument systems

    Science.gov (United States)

    Weitz, Karl K [Pasco, WA; Moore, Ronald J [West Richland, WA

    2010-07-13

    A method and device are disclosed that provide for detection of fluid leaks in analytical instruments and instrument systems. The leak detection device includes a collection tube, a fluid absorbing material, and a circuit that electrically couples to an indicator device. When assembled, the leak detection device detects and monitors for fluid leaks, providing a preselected response in conjunction with the indicator device when contacted by a fluid.

  15. Accounting, accountability and ethics in public sector organizations: towards a duality between instrumental accountability and relational response-ability

    NARCIS (Netherlands)

    Vosselman, E.G.J.

    2016-01-01

    This article challenges the performativity of organizational economics in the construction of “nexus-of-contract” organizations (or market bureaucracies) and inherent frames of instrumental accountability in the public sector. It argues for a duality between instrumental accountability and

  16. Accounting, accountability and ethics in public sector organizations: towards a duality between instrumental accountability and relational response-ability.

    NARCIS (Netherlands)

    Vosselman, E.G.J.

    2016-01-01

    This article challenges the performativity of organizational economics in the construction of “nexus-of-contract” organizations (or market bureaucracies) and inherent frames of instrumental accountability in the public sector. It argues for a duality between instrumental accountability and

  17. Virtual experiment instrument of nuclear pulse measuring

    International Nuclear Information System (INIS)

    Shan Jian; Zhao Xiuliang; Yu Hong; Zhang Meiqin

    2009-01-01

    Study on the scheme of application of virtual instrument(VI) technique in measuring of nuclear pulse. The system of Counter based on technology of LabVIEW and NI company's products USB-6009-DAQ is developed. Virtual nuclear instrument-Virtual Counter is realized. This system extends the application of technology of virtual instrument. The experimental results indicate that the system of Counter had the good counting measuring function of Nuclear Pulse. (authors)

  18. Optimising the effect of policy instruments

    DEFF Research Database (Denmark)

    Pedersen, Anders Branth; Nielsen, Helle Ørsted; Christensen, Tove

    2012-01-01

    Economic modelling generally assumes that businesses are profit maximisers. However, behavioural economics holds that businesses pursue multiple objectives and may even sacrifice some profit. This has implications for the effectiveness of incentive-based environmental policies. Using Danish farme...... to policy instruments; farmers who focus on yield indicate less responsiveness to economic policy instruments. The results imply that it is important to implement a broad array of policy instruments to match different farmer rationales.......Economic modelling generally assumes that businesses are profit maximisers. However, behavioural economics holds that businesses pursue multiple objectives and may even sacrifice some profit. This has implications for the effectiveness of incentive-based environmental policies. Using Danish farmers...... as a case, this paper examines whether non-economic rationales may trump economic ones in farmer decisions, and, unlike previous research, we quantify how widespread non-economic values are compared to more economic values. Data derive from a survey (1164 responses) of Danish conventional farmers' decision...

  19. Response functions for crystals and surfaces, with applications to surface scattering

    International Nuclear Information System (INIS)

    Barker, J.A.; Steele, W.A.

    1978-01-01

    A general solution of the equations of forced motion of a harmonic crystal or other vibrating system with arbitrary time-dependent forces acting on the atoms is given. The solution is given in terms of dynamical 'response functions', for which expressions in terms of the normal mode frequencies and eigenvectors (polarization vectors) are given. Numerical calculations of the response functions are described for (111) and (100) surfaces of face-centered cubic crystals interacting with Lennard-Jones 6-12 potentials, and the qualitative features of the surface and bulk response functions are discussed. The use of these functions in problems of atomic scattering from surface is outlined, and convenient parametrized forms for this application are given. (Auth.)

  20. Bronchodilator response of advanced lung function parameters depending on COPD severity

    Directory of Open Access Journals (Sweden)

    Jarenbäck L

    2016-11-01

    Full Text Available Linnea Jarenbäck,1 Göran Eriksson,1 Stefan Peterson,2 Jaro Ankerst,1 Leif Bjermer,1 Ellen Tufvesson1 1Respiratory Medicine and Allergology, Department of Clinical Sciences Lund, Lund University, 2Regional Cancer Center South, Skåne University Hospital, Lund, Sweden Background: COPD is defined as partly irreversible airflow obstruction. The response pattern of bronchodilators has not been followed in advanced lung function parameters. Purpose: The aim of this study was to investigate bronchodilator response pattern in advanced lung function parameters in a continuous fashion along forced expiratory volume in 1 second (FEV1 percent predicted (%p in COPD patients and controls. Patients and methods: Eighty-one smokers/ex-smokers (41 controls and 40 COPD performed spirometry, body plethysmography, impulse oscillometry and single-breath helium dilution carbon monoxide diffusion at baseline, after salbutamol inhalation and then after an additional inhalation of ipratropium. Results: Most pulmonary function parameters showed a linear increase in response to decreased FEV1%p. The subjects were divided into groups of FEV1%p <65 and >65, and the findings from continuous analysis were verified. The exceptions to this linear response were inspiratory capacity (IC, forced vital capacity (FVC, FEV1/FVC and expiratory resistance (Rex, which showed a segmented response relationship to FEV1%p. IC and FVC, with break points (BP of 57 and 58 FEV1%p respectively, showed no response above, but an incresed slope below the BP. In addition, in patients with FEV1%p <65 and >65, response of FEV1%p did not correlate to response of volume parameters. Conclusion: Response of several advanced lung function parameters differs depending on patients’ baseline FEV1%p, and specifically response of volume parameters is most pronounced in COPD patients with FEV1%p <65. Volume and resistance responses do not follow the flow response measured with FEV1 and may thus be used as a

  1. MIT Participation in the Data Analysis of the XRS and XIS Instruments on the Astro-E2 Mission

    Science.gov (United States)

    Bautz, Mark

    2005-01-01

    Since the inception of this grant six weeks ago, we have completed the initial activation of the Suzaku X-ray Imaging Spectrometer (XIS) (on 13 August) and we have supported initial calibration observations. The instrument is performing very well in all respects. We have characterized the spectral resolution and effective area of each XIS sensor. We are especially excited about the scientific opportunities provided by the XIS'S back- illuminated sensor, which exhibits spectral resolution in the sub-keV band unmatched by any X-ray CCD currently in orbit. As specified in our proposal, we have established a web site (http://space.mit.edu/XIS) on which we maintain an up-to-date summary of instrument performance characteristics. Gain, spectral resolution and system noise, as well as residual background rates, are currently available on this site. Although the particle background level is low compared with Chandra and XMM, we are currently evaluating methods to reduce it still further. Techniques under study include use of 5x5 mode information and alternative grade selection methods. Although the primary responsibility for development of instrument response functions rests with our Japanese colleagues, we are incorporating our latest measurements of spectral resolution into some temporary response functions which we hope to make available to the Suzaku General Observer Facility and the Science Working Group(SWG). We are also preparing proposals for use of SWG observing time.

  2. Intelligent instrumentation principles and applications

    CERN Document Server

    Bhuyan, Manabendra

    2011-01-01

    With the advent of microprocessors and digital-processing technologies as catalyst, classical sensors capable of simple signal conditioning operations have evolved rapidly to take on higher and more specialized functions including validation, compensation, and classification. This new category of sensor expands the scope of incorporating intelligence into instrumentation systems, yet with such rapid changes, there has developed no universal standard for design, definition, or requirement with which to unify intelligent instrumentation. Explaining the underlying design methodologies of intelligent instrumentation, Intelligent Instrumentation: Principles and Applications provides a comprehensive and authoritative resource on the scientific foundations from which to coordinate and advance the field. Employing a textbook-like language, this book translates methodologies to more than 80 numerical examples, and provides applications in 14 case studies for a complete and working understanding of the material. Beginn...

  3. Executive functioning complaints and escitalopram treatment response in late-life depression.

    Science.gov (United States)

    Manning, Kevin J; Alexopoulos, George S; Banerjee, Samprit; Morimoto, Sarah Shizuko; Seirup, Joanna K; Klimstra, Sibel A; Yuen, Genevieve; Kanellopoulos, Theodora; Gunning-Dixon, Faith

    2015-05-01

    Executive dysfunction may play a key role in the pathophysiology of late-life depression. Executive dysfunction can be assessed with cognitive tests and subjective report of difficulties with executive skills. The present study investigated the association between subjective report of executive functioning complaints and time to escitalopram treatment response in older adults with major depressive disorder (MDD). 100 older adults with MDD (58 with executive functioning complaints and 42 without executive functioning complaints) completed a 12-week trial of escitalopram. Treatment response over 12 weeks, as measured by repeated Hamilton Depression Rating Scale scores, was compared for adults with and without executive complaints using mixed-effects modeling. Mixed effects analysis revealed a significant group × time interaction, F(1, 523.34) = 6.00, p = 0.01. Depressed older adults who reported executive functioning complaints at baseline demonstrated a slower response to escitalopram treatment than those without executive functioning complaints. Self-report of executive functioning difficulties may be a useful prognostic indicator for subsequent speed of response to antidepressant medication. Copyright © 2015 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.

  4. Response functions for infinite fermion systems with velocity dependent interactions

    International Nuclear Information System (INIS)

    Garcia-Recio, C.; Salcedo, L.L.; Navarro, J.; Nguyen Van Giai

    1991-01-01

    Response functions of infinite Fermi systems are studied in the framework of the self-consistent Random Phase Approximation. Starting from an effective interaction with velocity and density dependence, or equivalently from a local energy density functional, algebraic expressions for the RPA response function are derived. Simple formulae for the energy-weighted and polarizability sum rules are obtained. The method is illustrated by applications to nuclear matter and liquid 3 He. In nuclear matter, it is shown that existing Skyrme interactions give spin-isospin response functions close to those calculated with finite range interactions. The different renormalization of longitudinal and transverse Coulomb sum rules in nuclear matter is discussed. In 3 He, the low-lying collective spin oscillation can be well described in a wide range of momenta with a Skyrme-type interaction if the relevant Landau parameters are fitted. For the high-lying density oscillation, the introduction of a finite range term in the energy functional improves considerably the agreement with the data. (author) 54 refs., 19 figs., 4 tabs

  5. Frequency response functions for nonlinear convergent systems

    NARCIS (Netherlands)

    Pavlov, A.V.; Wouw, van de N.; Nijmeijer, H.

    2007-01-01

    Convergent systems constitute a practically important class of nonlinear systems that extends the class of asymptotically stable linear time-invariant systems. In this note, we extend frequency response functions defined for linear systems to nonlinear convergent systems. Such nonlinear frequency

  6. Measurement and simulation of neutron response function of organic liquid scintillator detector

    International Nuclear Information System (INIS)

    Gohil, M.; Banerjee, K.; Bhattacharya, S.; Bhattacharya, C.; Kundu, S.; Rana, T.K.; Mukherjee, G.; Meena, J.K.; Pandey, R.; Pai, H.; Ghosh, T.K.; Dey, A.; Mukhopadhyay, S.; Pandit, D.; Pal, S.; Banerjee, S.R.; Bandhopadhyay, T.

    2012-01-01

    Response functions of monoenergetic neutrons at various energies, corresponding to a measured neutron energy spectrum have been extracted. The experimental response functions for neutron energies in the range of ∼2-20 MeV have been compared with the respective GEANT4 predictions. It has been found that, there is some discrepancy between the experimental and the GEANT4 simulated neutron response functions at lower pulse height regions, which increases with the increase of neutron energy. This might be due to the incompleteness of the physics processes used in the present GEANT4 simulations. In particular, higher order reaction processes which become more significant at higher energies should be properly taken into account in the calculation of response function.

  7. Development of the Parent Responses to School Functioning Questionnaire.

    Science.gov (United States)

    Barber Garcia, Brittany N; Gray, Laura S; Simons, Laura E; Logan, Deirdre E

    2017-10-01

    Parents play an important role in supporting school functioning in youth with chronic pain, but no validated tools exists to assess parental responses to child and adolescent pain behaviors in the school context. Such a tool would be useful in identifying targets of change to reduce pain-related school impairment. The goal of this study was to develop and preliminarily validate the Parent Responses to School Functioning Questionnaire (PRSF), a parent self-report measure of this construct. After initial expert review and pilot testing, the measure was administered to 418 parents of children (ages 6-17 years) seen for initial multidisciplinary chronic pain clinic evaluation. The final 16-item PRSF showed evidence of good internal consistency (α = .82) and 2-week test-retest reliability (intraclass correlation coefficient = .87). Criterion validity was demonstrated by significant correlations with school absence rates and overall school functioning, and construct validity was demonstrated by correlations with general parental responses to pain. Three subscales emerged capturing parents' personal distress, parents' level of distrust of the school, and parents' expectations and behaviors related to their child's management of challenging school situations. These results provide preliminary support for the PRSF as a psychometrically sound tool to assess parents' responses to child pain in the school setting. The 16-item PRSF measures parental responses to their child's chronic pain in the school context. The clinically useful measure can inform interventions aimed reducing functional disability in children with chronic pain by enhancing parents' ability to respond adaptively to child pain behaviors. Copyright © 2017 American Pain Society. Published by Elsevier Inc. All rights reserved.

  8. Comparison and selection of client computer in nuclear instrument

    International Nuclear Information System (INIS)

    Ma Guizhen; Xie Yanhui; Peng Jing; Xu Feiyan

    2012-01-01

    The function of modern new nuclear instrument is very much. And the information degree is high requested. Through close matching for host computer and client computer, the data processing function can be carried out. This article puts forward a few of projects for the client computer of general nuclear instrument. The function and features of several common client computers, such as FPGA, ARM and DSP, are analyzed and compared. The applied scope is discussed also. At the same time, using a practical design as an example, the selection ideas of client computer are described. This article can be used for reference for the hardware design of data acquisition processing unit in nuclear instrument. (authors)

  9. The response of electrostatic probes via the λ-function

    DEFF Research Database (Denmark)

    Rerup, T.O.; Crichton, George C; McAllister, Iain Wilson

    1994-01-01

    The response of an electrostatic probe is examined with reference to a planar spacer. The study involves the numerical calculation of the probe λ-function, from which response-related characteristic parameters can be derived. These parameters enable the probe detection sensitivity and spatial...

  10. Ecosystem functional response across precipitation extremes in a sagebrush steppe.

    Science.gov (United States)

    Tredennick, Andrew T; Kleinhesselink, Andrew R; Taylor, J Bret; Adler, Peter B

    2018-01-01

    Precipitation is predicted to become more variable in the western United States, meaning years of above and below average precipitation will become more common. Periods of extreme precipitation are major drivers of interannual variability in ecosystem functioning in water limited communities, but how ecosystems respond to these extremes over the long-term may shift with precipitation means and variances. Long-term changes in ecosystem functional response could reflect compensatory changes in species composition or species reaching physiological thresholds at extreme precipitation levels. We conducted a five year precipitation manipulation experiment in a sagebrush steppe ecosystem in Idaho, United States. We used drought and irrigation treatments (approximately 50% decrease/increase) to investigate whether ecosystem functional response remains consistent under sustained high or low precipitation. We recorded data on aboveground net primary productivity (ANPP), species abundance, and soil moisture. We fit a generalized linear mixed effects model to determine if the relationship between ANPP and soil moisture differed among treatments. We used nonmetric multidimensional scaling to quantify community composition over the five years. Ecosystem functional response, defined as the relationship between soil moisture and ANPP, was similar among irrigation and control treatments, but the drought treatment had a greater slope than the control treatment. However, all estimates for the effect of soil moisture on ANPP overlapped zero, indicating the relationship is weak and uncertain regardless of treatment. There was also large spatial variation in ANPP within-years, which contributes to the uncertainty of the soil moisture effect. Plant community composition was remarkably stable over the course of the experiment and did not differ among treatments. Despite some evidence that ecosystem functional response became more sensitive under sustained drought conditions, the response

  11. Functionally unidimensional item response models for multivariate binary data

    DEFF Research Database (Denmark)

    Ip, Edward; Molenberghs, Geert; Chen, Shyh-Huei

    2013-01-01

    The problem of fitting unidimensional item response models to potentially multidimensional data has been extensively studied. The focus of this article is on response data that have a strong dimension but also contain minor nuisance dimensions. Fitting a unidimensional model to such multidimensio......The problem of fitting unidimensional item response models to potentially multidimensional data has been extensively studied. The focus of this article is on response data that have a strong dimension but also contain minor nuisance dimensions. Fitting a unidimensional model...... to such multidimensional data is believed to result in ability estimates that represent a combination of the major and minor dimensions. We conjecture that the underlying dimension for the fitted unidimensional model, which we call the functional dimension, represents a nonlinear projection. In this article we investigate...... tool. An example regarding a construct of desire for physical competency is used to illustrate the functional unidimensional approach....

  12. Approaches of High School Instrumental Music Educators in Response to Student Challenges

    Science.gov (United States)

    Edgar, Scott N.

    2016-01-01

    The purpose of this multiple instrumental case study was to explore approaches of four high school instrumental music educators assuming the role of facilitative teacher in responding to challenges affecting the social and emotional well-being of their students. This study utilized the framework of social emotional learning as a lens to view the…

  13. Optical response from functionalized atomically thin nanomaterials

    Energy Technology Data Exchange (ETDEWEB)

    Malic, Ermin; Berghaeuser, Gunnar; Feierabend, Maja [Department of Physics, Chalmers University of Technology, Gothenburg (Sweden); Knorr, Andreas [Institut fuer Theoretische Physik, Technische Universitaet Berlin (Germany)

    2017-10-15

    Chemical functionalization of atomically thin nanostructures presents a promising strategy to create new hybrid nanomaterials with remarkable and externally controllable properties. Here, we review our research in the field of theoretical modeling of carbon nanotubes, graphene, and transition metal dichalcogenides located in molecular dipole fields. In particular, we provide a microscopic view on the change of the optical response of these technologically promising nanomaterials due to the presence of photo-active spiropyran molecules. The feature article presents a review of recent theoretical work providing microscopic view on the optical response of chemically functionalized carbon nanotubes, graphene, and monolayered transition metal dichalcogenides. In particular, we propose a novel sensor mechanism based on the molecule-induced activation of dark excitons. This results in a pronounced additional peak presenting an unambiguous optical fingerprint for the attached molecules. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  14. Experimentation of RT-LOTOS for a critical function of a power plant instrumentation and control system

    International Nuclear Information System (INIS)

    Andriantsiiferana, L.; Courtiat, J.P.; De Oliveira, R.C.

    1996-01-01

    This document is the final report of the contract between LAAS-CNRS and the EdF Direction of Researches and Studies about the experimentation of RT-LOTOS formal description technique on a critical function of a nuclear power plant instrumentation and control system. This report comprises 4 parts: part 1 describes the RT-LOTOS (Real Time-Language of Temporal Ordering Specifications) tutorial and its RTL tool environment, the different RT-LOTOS operators and semantics, and the RTL tool main functionalities; part 2 deals with the methodology and the global architecture for the specification and validation of the CCT (Central Calculator for Treatment); part 3 gives more details about the different processes identified in the specification architecture and presents the main results obtained for the validation of the nominal functioning; part 4 describes some exceptional situations and shows how some failures and their associated recovery mechanisms can be modelled. (J.S.). 6 refs., 53 figs., 5 tabs., 2 appends

  15. A near infrared instrument to monitor relative hemoglobin concentrations of human bone tissue in vitro and in vivo

    Science.gov (United States)

    Aziz, Syed Mahfuzul; Khambatta, Faram; Vaithianathan, Tharshan; Thomas, John C.; Clark, Jillian M.; Marshall, Ruth

    2010-04-01

    A continuous wave near infrared instrument has been developed to monitor in vivo changes in the hemoglobin concentration of the trabecular compartment of human bone. The transmitter uses only two laser diodes of wavelengths 685 and 830 nm, and the receiver uses a single silicon photodiode operating in the photovoltaic mode. The functioning of the instrument and the depth of penetration of the near infrared signals was determined in vitro using tissue-equivalent phantoms. The instrument achieves a depth of penetration of approximately 2 cm for an optode separation of 4 cm and, therefore, has the capacity to interrogate the trabecular compartment of human bone. The functioning of the instrument was tested in vivo to evaluate the relative oxy-hemoglobin (HbO2) and deoxy-hemoglobin (Hb) concentrations of the proximal tibial bone of apparently healthy, normal weight, adult subjects in response to a 3 min on, 5 min off, vascular occlusion protocol. The traces of the relative Hb and HbO2 concentrations obtained were reproducible in controlled conditions. The instrument is relatively simple and flexible, and offers an inexpensive platform for further studies to obtain normative data for healthy cohorts, and to evaluate disease-specific performance characteristics for cohorts with vasculopathies of bone.

  16. Developing a workplace resilience instrument.

    Science.gov (United States)

    Mallak, Larry A; Yildiz, Mustafa

    2016-05-27

    Resilience benefits from the use of protective factors, as opposed to risk factors, which are associated with vulnerability. Considerable research and instrument development has been conducted in clinical settings for patients. The need existed for an instrument to be developed in a workplace setting to measure resilience of employees. This study developed and tested a resilience instrument for employees in the workplace. The research instrument was distributed to executives and nurses working in the United States in hospital settings. Five-hundred-forty completed and usable responses were obtained. The instrument contained an inventory of workplace resilience, a job stress questionnaire, and relevant demographics. The resilience items were written based on previous work by the lead author and inspired by Weick's [1] sense-making theory. A four-factor model yielded an instrument having psychometric properties showing good model fit. Twenty items were retained for the resulting Workplace Resilience Instrument (WRI). Parallel analysis was conducted with successive iterations of exploratory and confirmatory factor analyses. Respondents were classified based on their employment with either a rural or an urban hospital. Executives had significantly higher WRI scores than nurses, controlling for gender. WRI scores were positively and significantly correlated with years of experience and the Brief Job Stress Questionnaire. An instrument to measure individual resilience in the workplace (WRI) was developed. The WRI's four factors identify dimensions of workplace resilience for use in subsequent investigations: Active Problem-Solving, Team Efficacy, Confident Sense-Making, and Bricolage.

  17. Trained Musical Performers' and Musically Untrained College Students' Ability to Discriminate Music Instrument Timbre as a Function of Duration.

    Science.gov (United States)

    Johnston, Dennis Alan

    The purpose of this study was to investigate the ability of trained musicians and musically untrained college students to discriminate music instrument timbre as a function of duration. Specific factors investigated were the thresholds for timbre discrimination as a function of duration, musical ensemble participation as training, and the relative discrimination abilities of vocalists and instrumentalists. The subjects (N = 126) were volunteer college students from intact classes from various disciplines separated into musically untrained college students (N = 43) who had not participated in musical ensembles and trained musicians (N = 83) who had. The musicians were further divided into instrumentalists (N = 51) and vocalists (N = 32). The Method of Constant Stimuli, using a same-different response procedure with 120 randomized, counterbalanced timbre pairs comprised of trumpet, clarinet, or violin, presented in durations of 20 to 100 milliseconds in a sequence of pitches, in two blocks was used for data collection. Complete, complex musical timbres were recorded digitally and presented in a sequence of changing pitches to more closely approximate an actual music listening experience. Under the conditions of this study, it can be concluded that the threshold for timbre discrimination as a function of duration is at or below 20 ms. Even though trained musicians tended to discriminate timbre better than musically untrained college students, musicians cannot discriminate timbre significantly better then those subjects who have not participated in musical ensembles. Additionally, instrumentalists tended to discriminate timbre better than vocalists, but the discrimination is not significantly different. Recommendations for further research include suggestions for a timbre discrimination measurement tool that takes into consideration the multidimensionality of timbre and the relationship of timbre discrimination to timbre source, duration, pitch, and loudness.

  18. Instrument to collect fogwater for chemical analysis

    OpenAIRE

    Jacob, Daniel J.; Waldman, Jed M.; Haghi, Mehrdad; Hoffmann, Michael R.; Flagan, Richard C.

    1985-01-01

    An instrument is presented which collects large samples of ambient fogwater by impaction of droplets on a screen. The collection efficiency of the instrument is determined as a function of droplet size, and it is shown that fog droplets in the range 3–100-µm diameter are efficiently collected. No significant evaporation or condensation occurs at any stage of the collection process. Field testing indicates that samples collected are representative of the ambient fogwater. The instrument may ea...

  19. Semi-classical calculation of the spin-isospin response functions

    International Nuclear Information System (INIS)

    Chanfray, G.

    1987-03-01

    We present a semi-classical calculation of the nuclear response functions beyond the Thomas-Fermi approximation. We apply our formalism to the spin-isospin responses and show that the surface peaked h/2π corrections considerably decrease the ratio longitudinal/transverse as obtained through hadronic probes

  20. Stimulus-response functions of single avian olfactory bulb neurones.

    Science.gov (United States)

    McKeegan, Dorothy E F; Demmers, Theodorus G M; Wathes, Christopher M; Jones, R Bryan; Gentle, Michael J

    2002-10-25

    This study investigated olfactory processing in a functional context by examining the responses of single avian olfactory bulb neurones to two biologically important gases over relevant concentration ranges. Recordings of extracellular spike activity were made from 80 single units in the left olfactory bulb of 11 anaesthetised, freely breathing adult hens (Gallus domesticus). The units were spontaneously active, exhibiting widely variable firing rates (0.07-47.28 spikes/s) and variable temporal firing patterns. Single units were tested for their response to an ascending concentration series of either ammonia (2.5-100 ppm) or hydrogen sulphide (1-50 ppm), delivered directly to the olfactory epithelium. Stimulation with a calibrated gas delivery system resulted in modification of spontaneous activity causing either inhibition (47% of units) or excitation (53%) of firing. For ammonia, 20 of the 35 units tested exhibited a response, while for hydrogen sulphide, 25 of the 45 units tested were responsive. Approximate response thresholds for ammonia (median threshold 3.75 ppm (range 2.5-60 ppm, n=20)) and hydrogen sulphide (median threshold 1 ppm (range 1-10 ppm, n=25)) were determined with most units exhibiting thresholds near the lower end of these ranges. Stimulus response curves were constructed for 23 units; 16 (the most complete) were subjected to a linear regression analysis to determine whether they were best fitted by a linear, log or power function. No single function provided the best fit for all the curves (seven were linear, eight were log, one was power). These findings show that avian units respond to changes in stimulus concentration in a manner generally consistent with reported responses in mammalian olfactory bulb neurones. However, this study illustrates a level of fine-tuning to small step changes in concentration (<5 ppm) not previously demonstrated in vertebrate single olfactory bulb neurones.

  1. An actuated force feedback-enabled laparoscopic instrument for robotic-assisted surgery.

    Science.gov (United States)

    Moradi Dalvand, Mohsen; Shirinzadeh, Bijan; Shamdani, Amir Hossein; Smith, Julian; Zhong, Yongmin

    2014-03-01

    Robotic-assisted minimally invasive surgery systems not only have the advantages of traditional laparoscopic instruments but also have other important advantages, including restoring the surgeon's hand-eye coordination and improving the surgeon's precision by filtering hand tremors. Unfortunately, these benefits have come at the expense of the surgeon's ability to feel. Various solutions for restoring this feature have been proposed. An actuated modular force feedback-enabled laparoscopic instrument was proposed that is able to measure tip-tissue lateral interaction forces as well as normal grasping forces. The instrument has also the capability to adjust the grasping direction inside the patient body. In order to measure the interaction forces, strain gauges were employed. A series of finite element analyses were performed to gain an understanding of the actual magnitude of surface strains where gauges are applied. The strain gauge bridge configurations were calibrated. A series of experiments was conducted and the results were analysed. The modularity feature of the proposed instrument makes it interchangeable between various tip types of different functionalities (e.g. cutter, grasper, dissector). Calibration results of the strain gauges incorporated into the tube and at the base of the instrument presented the monotonic responses for these strain gauge configurations. Experimental results from tissue probing and tissue characterization experiments verified the capability of the proposed instrument in measuring lateral probing forces and characterizing artificial tissue samples of varying stiffness. The proposed instrument can improve the quality of palpation and characterization of soft tissues of varying stiffness by restoring sense of touch in robotic assisted minimally invasive surgery operations. Copyright © 2013 John Wiley & Sons, Ltd.

  2. A hierarchical instrumental decision theory of nicotine dependence.

    Science.gov (United States)

    Hogarth, Lee; Troisi, Joseph R

    2015-01-01

    It is important to characterize the learning processes governing tobacco-seeking in order to understand how best to treat this behavior. Most drug learning theories have adopted a Pavlovian framework wherein the conditioned response is the main motivational process. We favor instead a hierarchical instrumental decision account, wherein expectations about the instrumental contingency between voluntary tobacco-seeking and the receipt of nicotine reward determines the probability of executing this behavior. To support this view, we review titration and nicotine discrimination research showing that internal signals for deprivation/satiation modulate expectations about the current incentive value of smoking, thereby modulating the propensity of this behavior. We also review research on cue-reactivity which has shown that external smoking cues modulate expectations about the probability of the tobacco-seeking response being effective, thereby modulating the propensity of this behavior. Economic decision theory is then considered to elucidate how expectations about the value and probability of response-nicotine contingency are integrated to form an overall utility estimate for that option for comparison with qualitatively different, nonsubstitute reinforcers, to determine response selection. As an applied test for this hierarchical instrumental decision framework, we consider how well it accounts for individual liability to smoking uptake and perseveration, pharmacotherapy, cue-extinction therapies, and plain packaging. We conclude that the hierarchical instrumental account is successful in reconciling this broad range of phenomenon precisely because it accepts that multiple diverse sources of internal and external information must be integrated to shape the decision to smoke.

  3. Test-retest reliability and cross validation of the functioning everyday with a wheelchair instrument.

    Science.gov (United States)

    Mills, Tamara L; Holm, Margo B; Schmeler, Mark

    2007-01-01

    The purpose of this study was to establish the test-retest reliability and content validity of an outcomes tool designed to measure the effectiveness of seating-mobility interventions on the functional performance of individuals who use wheelchairs or scooters as their primary seating-mobility device. The instrument, Functioning Everyday With a Wheelchair (FEW), is a questionnaire designed to measure perceived user function related to wheelchair/scooter use. Using consumer-generated items, FEW Beta Version 1.0 was developed and test-retest reliability was established. Cross-validation of FEW Beta Version 1.0 was then carried out with five samples of seating-mobility users to establish content validity. Based on the content validity study, FEW Version 2.0 was developed and administered to seating-mobility consumers to examine its test-retest reliability. FEW Beta Version 1.0 yielded an intraclass correlation coefficient (ICC) Model (3,k) of .92, p content validity results revealed that FEW Beta Version 1.0 captured 55% of seating-mobility goals reported by consumers across five samples. FEW Version 2.0 yielded ICC(3,k) = .86, p content validity of FEW Version 2.0 was confirmed. FEW Beta Version 1.0 and FEW Version 2.0 were highly stable in their measurement of participants' seating-mobility goals over a 1-week interval.

  4. The N2N instrument to evaluate healthy work environments: an Italian validation.

    Science.gov (United States)

    Palese, Alvisa; Dante, Angelo; Tonzar, Laura; Balboni, Bernardo

    2014-02-01

    The aims of the study were to (a) validate N2N Healthy Work Environment tool, (b) assess the healthiness of work environments as perceived by nurses themselves and (c) identify the factors associated with Italian nurses' perception of work environment healthiness. The linguistic and cultural adaptation of USA-N2N Healthy Work Environments was achieved through a process of forward/backward translation. Content validity was assessed by three expert nurses. The stability of the instrument was checked with a test/retest evaluation. The instrument psychometric properties, the confirmatory factor analysis as well the healthiness of the work environment and its determinant factors were evaluated with a sample of 294 nurses. The content and face validity of the N2N Healthy Work Environment instrument was confirmed. The instrument demonstrated good internal consistency (α of 0.82), excellent stability values (ρ > 0.70) and high levels of acceptability (response rate: 96.4 %). The confirmatory factor analysis has corroborated the existence of two factors as documented in the original instrument (Mays et al. in J Nurs Manag 19:18-26, 2011). Eighty-seven (29.6 %) nurses perceived the work environment where they work as "healthy". Working under a functional model of care delivery (χ(2) 24.856, p 0.000) and being responsible for one project or more (χ(2) 5.256, p 0.021) were associated with healthy environments. The instrument--valid and reliable, short in the number of items, easy to understand and based on international standards--allows a systematic assessment of the healthiness of the environment and might provide not only the opportunity to evaluate the effects of new organizational models and interventions, but also the possibility to activate a process of self-analysis and a process of ongoing review. The instrument can be used to systematically check the healthiness of Italian working environments, allowing for organizational diagnosis, targeted interventions and

  5. Estimating soil hydrological response by combining precipitation-runoff modeling and hydro-functional soil homogeneous units

    Science.gov (United States)

    Aroca-Jimenez, Estefania; Bodoque, Jose Maria; Diez-Herrero, Andres

    2015-04-01

    Flash floods constitute one of the natural hazards better able to generate risk, particularly with regard to Society. The complexity of this process and its dependence on various factors related to the characteristics of the basin and rainfall make flash floods are difficult to characterize in terms of their hydrological response.To do this, it is essential a proper analysis of the so called 'initial abstractions'. Among all of these processes, infiltration plays a crucial role in explaining the occurrence of floods in mountainous basins.For its characterization the Green-Ampt model , which depends on the characteristics of rainfall and physical properties of soil has been used in this work.This is a method enabling to simulate floods in mountainous basins where hydrological response is sub-daily. However, it has the disadvantage that it is based on physical properties of soil which have a high spatial variability. To address this difficulty soil mapping units have been delineated according to the geomorphological landforms and elements. They represent hydro-functional mapping units that are theoretically homogeneous from the perspective of the pedostructure parameters of the pedon. So the soil texture of each homogeneous group of landform units was studied by granulometric analyses using standarized sieves and Sedigraph devices. In addition, uncertainty associated with the parameterization of the Green-Ampt method has been estimated by implementing a Monte Carlo approach, which required assignment of the proper distribution function to each parameter.The suitability of this method was contrasted by calibrating and validating a hydrological model, in which the generation of runoff hydrograph has been simulated using the SCS unit hydrograph (HEC-GeoHMS software), while flood wave routing has been characterized using the Muskingum-Cunge method. Calibration and validation of the model was from the use of an automatic routine based on the employ of the search algorithm

  6. Optimal hemodynamic response model for functional near-infrared spectroscopy

    Directory of Open Access Journals (Sweden)

    Muhammad Ahmad Kamran

    2015-06-01

    Full Text Available Functional near-infrared spectroscopy (fNIRS is an emerging non-invasive brain imaging technique and measures brain activities by means of near-infrared light of 650-950 nm wavelengths. The cortical hemodynamic response (HR differs in attributes at different brain regions and on repetition of trials, even if the experimental paradigm is kept exactly the same. Therefore, an HR model that can estimate such variations in the response is the objective of this research. The canonical hemodynamic response function (cHRF is modeled by using two Gamma functions with six unknown parameters. The HRF model is supposed to be linear combination of HRF, baseline and physiological noises (amplitudes and frequencies of physiological noises are supposed to be unknown. An objective function is developed as a square of the residuals with constraints on twelve free parameters. The formulated problem is solved by using an iterative optimization algorithm to estimate the unknown parameters in the model. Inter-subject variations in HRF and physiological noises have been estimated for better cortical functional maps. The accuracy of the algorithm has been verified using ten real and fifteen simulated data sets. Ten healthy subjects participated in the experiment and their HRF for finger-tapping tasks have been estimated and analyzed. The statistical significance of the estimated activity strength parameters has been verified by employing statistical analysis, i.e., (t-value >tcritical and p-value < 0.05.

  7. Optimal hemodynamic response model for functional near-infrared spectroscopy.

    Science.gov (United States)

    Kamran, Muhammad A; Jeong, Myung Yung; Mannan, Malik M N

    2015-01-01

    Functional near-infrared spectroscopy (fNIRS) is an emerging non-invasive brain imaging technique and measures brain activities by means of near-infrared light of 650-950 nm wavelengths. The cortical hemodynamic response (HR) differs in attributes at different brain regions and on repetition of trials, even if the experimental paradigm is kept exactly the same. Therefore, an HR model that can estimate such variations in the response is the objective of this research. The canonical hemodynamic response function (cHRF) is modeled by two Gamma functions with six unknown parameters (four of them to model the shape and other two to scale and baseline respectively). The HRF model is supposed to be a linear combination of HRF, baseline, and physiological noises (amplitudes and frequencies of physiological noises are supposed to be unknown). An objective function is developed as a square of the residuals with constraints on 12 free parameters. The formulated problem is solved by using an iterative optimization algorithm to estimate the unknown parameters in the model. Inter-subject variations in HRF and physiological noises have been estimated for better cortical functional maps. The accuracy of the algorithm has been verified using 10 real and 15 simulated data sets. Ten healthy subjects participated in the experiment and their HRF for finger-tapping tasks have been estimated and analyzed. The statistical significance of the estimated activity strength parameters has been verified by employing statistical analysis (i.e., t-value > t critical and p-value < 0.05).

  8. Planck 2013 results. VII. HFI time response and beams

    DEFF Research Database (Denmark)

    Planck Collaboration,; Ade, P. A. R.; Aghanim, N.

    2013-01-01

    This paper characterizes the effective beams, the effective beam window functions (EBWF) and the associated errors for the Planck High Frequency Instrument (HFI) detectors. The effective beam is the angular response including the effect of the optics, detectors, data processing and the scan strat...

  9. About instrumental innovation. Energy saving certificates

    International Nuclear Information System (INIS)

    Baiz, Adam; Monnoyer-Smith, Laurence

    2016-09-01

    Energy saving certificates (in French CEE for certificats d'economie d'energie) have been implemented in 2006, and have proven to be a rather efficient tool of public policy, with a low cost, and a good social acceptability, notably due to its hybrid nature (incentive and coercive) in function of the targeted actors. Thus, this document addresses and discusses the interest of such instruments for the public environmental policy. It outlines that instruments tend to be always less coercive, and then comments the example of these energy saving certificates: brief presentation, discussion and explanation of their efficiency, multi-dimensional nature of this instrument, benefits of more or less coercive instruments depending on the actors (State, households, energy providers)

  10. Functional MRI of food-induced brain responses

    NARCIS (Netherlands)

    Smeets, P.A.M.

    2006-01-01

    The ultimate goal of this research was to find central biomarkers of satiety, i.e., physiological measures in the brain that relate to subjectively rated appetite, actual food intake, or both. This thesis describes the changes in brain activity in response to food stimuli as measured by functional

  11. Chemokine receptors CXCR2 and CX3CR1 differentially regulate functional responses of bone-marrow endothelial progenitors during atherosclerotic plaque regression

    Science.gov (United States)

    Herlea-Pana, Oana; Yao, Longbiao; Heuser-Baker, Janet; Wang, Qiongxin; Wang, Qilong; Georgescu, Constantin; Zou, Ming-Hui; Barlic-Dicen, Jana

    2015-01-01

    Aims Atherosclerosis manifests itself as arterial plaques, which lead to heart attacks or stroke. Treatments supporting plaque regression are therefore aggressively pursued. Studies conducted in models in which hypercholesterolaemia is reversible, such as the Reversa mouse model we have employed in the current studies, will be instrumental for the development of such interventions. Using this model, we have shown that advanced atherosclerosis regression occurs when lipid lowering is used in combination with bone-marrow endothelial progenitor cell (EPC) treatment. However, it remains unclear how EPCs home to regressing plaques and how they augment atherosclerosis reversal. Here we identify molecules that support functional responses of EPCs during plaque resolution. Methods and results Chemokines CXCL1 and CX3CL1 were detected in the vascular wall of atheroregressing Reversa mice, and their cognate receptors CXCR2 and CX3CR1 were observed on adoptively transferred EPCs in circulation. We tested whether CXCL1–CXCR2 and CX3CL1–CX3CR1 axes regulate functional responses of EPCs during plaque reversal. We show that pharmacological inhibition of CXCR2 or CX3CR1, or genetic inactivation of these two chemokine receptors interfered with EPC-mediated advanced atherosclerosis regression. We also demonstrate that CXCR2 directs EPCs to regressing plaques while CX3CR1 controls a paracrine function(s) of these cells. Conclusion CXCR2 and CX3CR1 differentially regulate EPC functional responses during atheroregression. Our study improves understanding of how chemokines and chemokine receptors regulate plaque resolution, which could determine the effectiveness of interventions reducing complications of atherosclerosis. PMID:25765938

  12. Workshop on Advanced Technologies for Planetary Instruments, part 1

    International Nuclear Information System (INIS)

    Appleby, J.F.

    1993-01-01

    This meeting was conceived in response to new challenges facing NASA's robotic solar system exploration program. This volume contains papers presented at the Workshop on Advanced Technologies for Planetary Instruments on 28-30 Apr. 1993. This meeting was conceived in response to new challenges facing NASA's robotic solar system exploration program. Over the past several years, SDIO has sponsored a significant technology development program aimed, in part, at the production of instruments with these characteristics. This workshop provided an opportunity for specialists from the planetary science and DOD communities to establish contacts, to explore common technical ground in an open forum, and more specifically, to discuss the applicability of SDIO's technology base to planetary science instruments

  13. University Reactor Instrumentation Program

    International Nuclear Information System (INIS)

    Vernetson, W.G.

    1992-11-01

    Recognizing that the University Reactor Instrumentation Program was developed in response to widespread needs in the academic community for modernization and improvement of research and training reactors at institutions such as the University of Florida, the items proposed to be supported by this grant over its two year period have been selected as those most likely to reduce foreed outages, to meet regulatory concerns that had been expressed in recent years by Nuclear Regulatory Commission inspectors or to correct other facility problems and limitations. Department of Energy Grant Number DE-FG07-90ER129969 was provided to the University of Florida Training Reactor(UFTR) facility through the US Department of Energy's University Reactor Instrumentation Program. The original proposal submitted in February, 1990 requested support for UFTR facility instrumentation and equipment upgrades for seven items in the amount of $107,530 with $13,800 of this amount to be the subject of cost sharing by the University of Florida and $93,730 requested as support from the Department of Energy. A breakdown of the items requested and total cost for the proposed UFTR facility instrumentation and equipment improvements is presented

  14. New type of radiation instrumentation system

    International Nuclear Information System (INIS)

    Matsuo, Keichi; Takaoka, Akira; Uranaka, Yasuo

    2000-01-01

    The Mitsubishi Electric Co., Ltd. developed a radiation instrumentation system introduced some recent techniques such as computation technique, network technique and so on into conventional radiation detection aiming at general market except power generation company. In a conventional system, a detector and an operation processing board was placed at a field and center, respectively, and a feeble pulse signal from the detector was transferred to the operation processing board. Then, on establishment of cables, detectors and operation processing board, it is essential to carry out engineering planning and field engineering conceiving on noise countermeasure. Noise resistance of the new type of radiation instrumentation system, not by adding operation processing function and network interface function into a detector unit in a field to transfer feeble signal, but by transferring testing result as a digital signal. And, noise removing function capable of selectively passing only signal pulse waveform from the detector to judge its signal waveform was also added to a detector unit in the field, to carry out a thoroughly removing noise. In addition, by connecting between each apparatus placed at the field with a network a system capable of reducing some cable engineering could be executed. Here were introduced on abstract of this new type of radiation instrumentation system and on noise removing function of its characteristics. (G.K.)

  15. Value of musical instruments used by the therapist to elicit responses from individuals in various stages of Alzheimer's disease.

    Science.gov (United States)

    Cevasco, Andrea M; Grant, Roy E

    2006-01-01

    The purpose of this study was to determine the value of designated musical instruments used by the therapist to elicit responses from persons with Alzheimer's disease (AD) during group sessions. In Experiment 1, 15 individuals in the early and middle stages of AD echoed rhythm patterns played by the therapist via the djembe, claves, paddle drum, and maraca. Results indicated significance for the rhythm patterns used, p autoharp (54%). Average participation at any level in the four activities, without any consideration of instruments, was as follows: 83% for the rhythm activity, 51% for the movement activity, and 49% for the first as well as second singing activity. Results indicated significant differences for the treatment conditions, p < .001, and for types of activities, p < .05. Significant difference, p < .01, occurred for interaction of treatment condition by activity.

  16. Physical characterisation of endodontic instruments in NiTi alloy

    International Nuclear Information System (INIS)

    Torrisi, L.

    2000-01-01

    NiTi based endodontic instruments are investigated in functionality and wear. The instrument surfaces have been studied applying Auger electron spectroscopy, mechanical analysis, differential-scanning calorimetry, wear tests, and scanning electron microscopy. (orig.)

  17. Methodological substantiation of the professional functions of Responsible persons of pharmaceutical and hospital institutions

    Directory of Open Access Journals (Sweden)

    N. O. Vetiutneva

    2018-03-01

    Full Text Available The aim of the work is the content analysis and methodological justification of the professional functions of the Responsible persons for quality assurance of medicines in pharmaceutical and hospital institutions. Materials and methods. The following research methods were used: system and comparative analysis, generalization, systematization, graphic modeling, observation. Research materials: normative legal acts, normative documents, recommendations of international organizations, information of wholesale and retail pharmaceutical companies, pharmaceutical and hospital institutions, professional non-governmental organizations, placed on official web-sites and collected in the process of direct observation. Results. The personnel and qualification aspects of professional activity of Responsible persons of pharmaceutical and hospital institutions were discussed. On the basis of analysis of the modern legal and regulatory framework, a general list of professional functions of the Responsible persons of health care institutions had been formed. The content analysis and comparison of the number of the functions of Responsible persons performed in health care institutions of different types is carried out. The new functions of the Responsible persons of health care institutions are considered. The managerial nature of the professional functions of the Responsible persons and the expediency of their complementing with the leadership functions are substantiated. On the basis of international management standards, requirements of GPP and GPEP, systematization of the functions of the Responsible persons of health care institutions in the groups and subgroups was performed. Conclusions. The generalization and systematization of the professional functions of the Responsible persons of health care institutions had been carried out for five classification groups of functions, namely: leadership, planning, organizational, control and information, of which the

  18. The positive mental health instrument: development and validation of a culturally relevant scale in a multi-ethnic asian population

    Directory of Open Access Journals (Sweden)

    Vaingankar Janhavi

    2011-10-01

    Full Text Available Abstract Background Instruments to measure mental health and well-being are largely developed and often used within Western populations and this compromises their validity in other cultures. A previous qualitative study in Singapore demonstrated the relevance of spiritual and religious practices to mental health, a dimension currently not included in exiting multi-dimensional measures. The objective of this study was to develop a self-administered measure that covers all key and culturally appropriate domains of mental health, which can be applied to compare levels of mental health across different age, gender and ethnic groups. We present the item reduction and validation of the Positive Mental Health (PMH instrument in a community-based adult sample in Singapore. Methods Surveys were conducted among adult (21-65 years residents belonging to Chinese, Malay and Indian ethnicities. Exploratory and confirmatory factor analysis (EFA, CFA were conducted and items were reduced using item response theory tests (IRT. The final version of the PMH instrument was tested for internal consistency and criterion validity. Items were tested for differential item functioning (DIF to check if items functioned in the same way across all subgroups. Results: EFA and CFA identified six first-order factor structure (General coping, Personal growth and autonomy, Spirituality, Interpersonal skills, Emotional support, and Global affect under one higher-order dimension of Positive Mental Health (RMSEA = 0.05, CFI = 0.96, TLI = 0.96. A 47-item self-administered multi-dimensional instrument with a six-point Likert response scale was constructed. The slope estimates and strength of the relation to the theta for all items in each six PMH subscales were high (range:1.39 to 5.69, suggesting good discrimination properties. The threshold estimates for the instrument ranged from -3.45 to 1.61 indicating that the instrument covers entire spectrums for the six dimensions. The

  19. Nonparametric instrumental regression with non-convex constraints

    International Nuclear Information System (INIS)

    Grasmair, M; Scherzer, O; Vanhems, A

    2013-01-01

    This paper considers the nonparametric regression model with an additive error that is dependent on the explanatory variables. As is common in empirical studies in epidemiology and economics, it also supposes that valid instrumental variables are observed. A classical example in microeconomics considers the consumer demand function as a function of the price of goods and the income, both variables often considered as endogenous. In this framework, the economic theory also imposes shape restrictions on the demand function, such as integrability conditions. Motivated by this illustration in microeconomics, we study an estimator of a nonparametric constrained regression function using instrumental variables by means of Tikhonov regularization. We derive rates of convergence for the regularized model both in a deterministic and stochastic setting under the assumption that the true regression function satisfies a projected source condition including, because of the non-convexity of the imposed constraints, an additional smallness condition. (paper)

  20. Nonparametric instrumental regression with non-convex constraints

    Science.gov (United States)

    Grasmair, M.; Scherzer, O.; Vanhems, A.

    2013-03-01

    This paper considers the nonparametric regression model with an additive error that is dependent on the explanatory variables. As is common in empirical studies in epidemiology and economics, it also supposes that valid instrumental variables are observed. A classical example in microeconomics considers the consumer demand function as a function of the price of goods and the income, both variables often considered as endogenous. In this framework, the economic theory also imposes shape restrictions on the demand function, such as integrability conditions. Motivated by this illustration in microeconomics, we study an estimator of a nonparametric constrained regression function using instrumental variables by means of Tikhonov regularization. We derive rates of convergence for the regularized model both in a deterministic and stochastic setting under the assumption that the true regression function satisfies a projected source condition including, because of the non-convexity of the imposed constraints, an additional smallness condition.

  1. A new design of neutron survey instrument

    International Nuclear Information System (INIS)

    Tanner, R.J.; Eakins, J.S.; Hager, L.G.

    2010-01-01

    A novel design of neutron survey instrument has been developed. The moderator has been modified via the use of 'neutron guides', which help thermal neutrons reach the central proportional counter. This innovation has allowed the variations in the energy dependence of ambient dose equivalent response to be reduced compared to prior single-detector designs, whilst maintaining a relatively light moderator and simple construction. In particular, the design has a relatively small over-response to neutrons with energies around 5 keV, when compared to prior designs. The final optimized design has been verified using MCNP5 calculations to ensure that the response is relatively independent of the energy and direction of the incident neutron. This has required the ends of the guides to be structured so that unidirectional and isotropic neutron fields have closely matched responses, as is necessary in the workplace. The reading of the instrument in workplace fields is calculated via folding and the suitability of the design for use in the workplace discussed.

  2. A mathematical function for the description of nutrient-response curve.

    Directory of Open Access Journals (Sweden)

    Hamed Ahmadi

    Full Text Available Several mathematical equations have been proposed to modeling nutrient-response curve for animal and human justified on the goodness of fit and/or on the biological mechanism. In this paper, a functional form of a generalized quantitative model based on Rayleigh distribution principle for description of nutrient-response phenomena is derived. The three parameters governing the curve a has biological interpretation, b may be used to calculate reliable estimates of nutrient response relationships, and c provide the basis for deriving relationships between nutrient and physiological responses. The new function was successfully applied to fit the nutritional data obtained from 6 experiments including a wide range of nutrients and responses. An evaluation and comparison were also done based simulated data sets to check the suitability of new model and four-parameter logistic model for describing nutrient responses. This study indicates the usefulness and wide applicability of the new introduced, simple and flexible model when applied as a quantitative approach to characterizing nutrient-response curve. This new mathematical way to describe nutritional-response data, with some useful biological interpretations, has potential to be used as an alternative approach in modeling nutritional responses curve to estimate nutrient efficiency and requirements.

  3. Bias Errors due to Leakage Effects When Estimating Frequency Response Functions

    Directory of Open Access Journals (Sweden)

    Andreas Josefsson

    2012-01-01

    Full Text Available Frequency response functions are often utilized to characterize a system's dynamic response. For a wide range of engineering applications, it is desirable to determine frequency response functions for a system under stochastic excitation. In practice, the measurement data is contaminated by noise and some form of averaging is needed in order to obtain a consistent estimator. With Welch's method, the discrete Fourier transform is used and the data is segmented into smaller blocks so that averaging can be performed when estimating the spectrum. However, this segmentation introduces leakage effects. As a result, the estimated frequency response function suffers from both systematic (bias and random errors due to leakage. In this paper the bias error in the H1 and H2-estimate is studied and a new method is proposed to derive an approximate expression for the relative bias error at the resonance frequency with different window functions. The method is based on using a sum of real exponentials to describe the window's deterministic autocorrelation function. Simple expressions are derived for a rectangular window and a Hanning window. The theoretical expressions are verified with numerical simulations and a very good agreement is found between the results from the proposed bias expressions and the empirical results.

  4. Designing Financial Instruments for Rapid Flood Response Using Remote Sensed and Archival Hazard and Exposure Information

    Science.gov (United States)

    Lall, U.; Allaire, M.; Ceccato, P.; Haraguchi, M.; Cian, F.; Bavandi, A.

    2017-12-01

    Catastrophic floods can pose a significant challenge for response and recovery. A key bottleneck in the speed of response is the availability of funds to a country or regions finance ministry to mobilize resources. Parametric instruments, where the release of funs is tied to the exceedance of a specified index or threshold, rather than to loss verification are well suited for this purpose. However, designing and appropriate index, that is not subject to manipulation and accurately reflects the need is a challenge, especially in developing countries which have short hydroclimatic and loss records, and where rapid land use change has led to significant changes in exposure and hydrology over time. The use of long records of rainfall from climate re-analyses, flooded area and land use from remote sensing to design and benchmark a parametric index considering the uncertainty and representativeness of potential loss is explored with applications to Bangladesh and Thailand. Prospects for broader applicability and limitations are discussed.

  5. Aging and response conflict solution: behavioural and functional connectivity changes.

    Science.gov (United States)

    Langner, Robert; Cieslik, Edna C; Behrwind, Simone D; Roski, Christian; Caspers, Svenja; Amunts, Katrin; Eickhoff, Simon B

    2015-01-01

    Healthy aging has been found associated with less efficient response conflict solution, but the cognitive and neural mechanisms have remained elusive. In a two-experiment study, we first examined the behavioural consequences of this putative age-related decline for conflicts induced by spatial stimulus-response incompatibility. We then used resting-state functional magnetic resonance imaging data from a large, independent sample of adults (n = 399; 18-85 years) to investigate age differences in functional connectivity between the nodes of a network previously found associated with incompatibility-induced response conflicts in the very same paradigm. As expected, overcoming interference from conflicting response tendencies took longer in older adults, even after accounting for potential mediator variables (general response speed and accuracy, motor speed, visuomotor coordination ability, and cognitive flexibility). Experiment 2 revealed selective age-related decreases in functional connectivity between bilateral anterior insula, pre-supplementary motor area, and right dorsolateral prefrontal cortex. Importantly, these age effects persisted after controlling for regional grey-matter atrophy assessed by voxel-based morphometry. Meta-analytic functional profiling using the BrainMap database showed these age-sensitive nodes to be more strongly linked to highly abstract cognition, as compared with the remaining network nodes, which were more strongly linked to action-related processing. These findings indicate changes in interregional coupling with age among task-relevant network nodes that are not specifically associated with conflict resolution per se. Rather, our behavioural and neural data jointly suggest that healthy aging is associated with difficulties in properly activating non-dominant but relevant task schemata necessary to exert efficient cognitive control over action.

  6. Development of NRESP98 Monte Carlo codes for the calculation of neutron response functions of neutron detectors. Calculation of the response function of spherical BF{sub 3} proportional counter

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, M.; Saito, K.; Ando, H. [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1998-05-01

    The method to calculate the response function of spherical BF{sub 3} proportional counter, which is commonly used as neutron dose rate meter and neutron spectrometer with multi moderator system, is developed. As the calculation code for evaluating the response function, the existing code series NRESP, the Monte Carlo code for the calculation of response function of neutron detectors, is selected. However, the application scope of the existing NRESP is restricted, the NRESP98 is tuned as generally applicable code, with expansion of the geometrical condition, the applicable element, etc. The NRESP98 is tested with the response function of the spherical BF{sub 3} proportional counter. Including the effect of the distribution of amplification factor, the detailed evaluation of the charged particle transportation and the effect of the statistical distribution, the result of NRESP98 calculation fit the experience within {+-}10%. (author)

  7. Use of spreadsheets for interactive control of MFTF-B plasma diagnostic instruments

    International Nuclear Information System (INIS)

    Preckshot, G.G.; Goldner, A.L.; Kobayashi, A.

    1986-01-01

    The Mirror Fusion Test Facility (MFTF-B) at Lawrence Livermore National Laboratory has a variety of highly individualized plasma diagnostic instruments attached to the experiment. These instruments are controlled through graphics workstations networked to a central computer system. A distributed spreadsheet-like program runs in both the graphics workstations and in the central computer system. An interface very similar to a commercial spreadsheet program is presented to the user at a workstation. In a commercial spreadsheet program, the user may attach mathematical calculation functions to spreadsheet cells. At MFTF-B, hardware control functions, hardware monitoring functions, and communications functions, as well as mathematical functions, may be attached to cells. Both the user and feedback from instrument hardware may make entries in spreadsheet cells; any entry in a spreadsheet cell may cause reevaluation of the cell's associated functions. The spreadsheet approach makes the addition of a new instrument a matter of designing one or more spreadsheet tables with associated meta-language-defined control and communication function strings. This paper describes the details of the spreadsheets and the implementation experience

  8. Use of spreadsheets for interactive control of MFTF-B plasma diagnostic instruments

    International Nuclear Information System (INIS)

    Preckshot, G.G.; Goldner, A.; Kobayashi, A.

    1985-01-01

    The Mirror Fusion Test Facility (MFTF-B) at Lawrence Livermore National Laboratory has a variety of highly individualized plasma diagnostic instruments attached to the experiment. These instruments are controlled through graphics workstations networked to a central computer system. A distributed spreadsheet-like program runs in both the graphics workstations and in the central computer system. An interface very similar to a commercial spreadsheet program is presented to the user at a workstation. In a commercial spreadsheet program, the user may attach mathematical calculation functions to spreadsheet cells. At MFTF-B, hardware control functions, hardware monitoring functions, and communications functions, as well as mathematical functions, may be attached to cells. Both the user and feedback from instrument hardware may make entries in spreadsheet cells; any entry in a spreadsheet cell may cause reevaluation of the cell's associated functions. The spreadsheet approach makes the addition of a new instrument a matter of designing one or more spreadsheet tables with associated meta-language-defined control and communication function strings. We report here details of our spreadsheets and our implementation experience

  9. Operating experience with LAMPF main beam lines instrumentation and control system

    International Nuclear Information System (INIS)

    van Dyck, O.B.; Harvey, A.; Howard, H.H.; Roeder, D.L.

    1975-01-01

    Instrumentation and control (I and C) for the Los Alamos Clinton P. Anderson Meson Physics Facility (LAMPF) main beam line is based upon central computer control through remote stations which provide input and output to most devices. Operating experience shows that the ability of the computer to give high-quality graphical presentation of the measurements enhances operator performance and instrument usefulness. Experience also shows that operator efficiency degrades rapidly with increasing instrument response time, that is, with increasing delay between the time a control is changed and the result can be observed. For this reason, instrumentation upgrade includes speeding up data acquisition and display times to under 10 s. Similarly, television-viewed phosphors are being retained where possible since their instantaneous response is very useful. Other upgrading of the instrumentation system is planned to improve data accuracy, reliability, redundancy, and instrument radiation tolerance. Past experience is being applied in adding or relocating devices to simplify tuning procedures. (U.S.)

  10. Malware Instrumentation Application to Regin Analysis

    Directory of Open Access Journals (Sweden)

    Matthieu Kaczmarek

    2015-12-01

    Full Text Available The complexity of the Regin malware underlines the importance of reverse engineering in modern incident response. The present study shows that such complexity can be overcome: substantial information about adversary tactics, techniques and procedures is obtained from reverse engineering. An introduction to the Regin development framework is provided along with instrumentation guidelines. Such instrumentation enables experimentation with malware modules. So analysis can derectly leverage malware’s own code without the need to program an analysis toolkit. As an application of the presented instrumentation, the underlying botnet architecture is analysed. Finally conclusions from different perspectives are provided: defense, attack and counter intelligence.

  11. Assessment of sexual difficulties associated with multi-modal treatment for cervical or endometrial cancer: A systematic review of measurement instruments.

    Science.gov (United States)

    White, Isabella D; Sangha, Amrit; Lucas, Grace; Wiseman, Theresa

    2016-12-01

    Practitioners and researchers require an outcome measure that accurately identifies the range of common treatment-induced changes in sexual function and well-being experienced by women after cervical or endometrial cancer. This systematic review critically appraised the measurement properties and clinical utility of instruments validated for the measurement of female sexual dysfunction (FSD) in this clinical population. A bibliographic database search for questionnaire development or validation papers was completed and methodological quality and measurement properties of selected studies rated using the Consensus-based Standards for the selection of health Measurement Instrument (COSMIN) checklist. 738 articles were screened, 13 articles retrieved for full text assessment and 7 studies excluded, resulting in evaluation of 6 papers; 2 QoL and 4 female sexual morbidity measures. Five of the six instruments omitted one or more dimension of female sexual function and only one instrument explicitly measured distress associated with sexual changes as per DSM V (APA 2013) diagnostic criteria. None of the papers reported measurement error, responsiveness data was available for only two instruments, three papers failed to report on criterion validity, and test-retest reliability reporting was inconsistent. Heterosexual penile-vaginal intercourse remains the dominant sexual activity focus for sexual morbidity PROMS terminology and instruments lack explicit reference to solo or non-coital sexual expression or validation in a non-heterosexual sample. Four out of six instruments included mediating treatment or illness items such as vaginal changes, menopause or altered body image. Findings suggest that the Female Sexual Function Index (FSFI) remains the most robust sexual morbidity outcome measure, for research or clinical use, in sexually active women treated for cervical or endometrial cancer. Development of an instrument that measures sexual dysfunction in women who are

  12. Health physics instruments: what are the current needs

    International Nuclear Information System (INIS)

    Armantrout, G.A.

    1982-01-01

    Health Physics instruments are used to measure the risk which may be incurred by an individual exposed to a given radiation field. The response of the instrument sensors will differ markedly from actual human risk factors for a variety of reasons, and this requires the use of instrument modifications and conversion factors. The values of these conversion factors continue to be updated and will likely change in the future. To accommodate the effects of different types of radiation and new conversion and usage factors, new instruments should be able to determine the type, energy distribution, and direction of incoming radiation and then apply the proper weighting factors to determine relative human risk. Such instrumentation will need to utilize modern sensor elements and microprocessor electronics

  13. Instrumentation & Data Acquisition System (D AS) Engineer

    Science.gov (United States)

    Jackson, Markus Deon

    2015-01-01

    The primary job of an Instrumentation and Data Acquisition System (DAS) Engineer is to properly measure physical phenomenon of hardware using appropriate instrumentation and DAS equipment designed to record data during a specified test of the hardware. A DAS system includes a CPU or processor, a data storage device such as a hard drive, a data communication bus such as Universal Serial Bus, software to control the DAS system processes like calibrations, recording of data and processing of data. It also includes signal conditioning amplifiers, and certain sensors for specified measurements. My internship responsibilities have included testing and adjusting Pacific Instruments Model 9355 signal conditioning amplifiers, writing and performing checkout procedures, writing and performing calibration procedures while learning the basics of instrumentation.

  14. Influence of soil and climate heterogeneity on the performance of economic instruments for reducing nitrate leaching from agriculture.

    Science.gov (United States)

    Peña-Haro, Salvador; García-Prats, Alberto; Pulido-Velazquez, Manuel

    2014-11-15

    Economic instruments can be used to control groundwater nitrate pollution due to the intensive use of fertilizers in agriculture. In order to test their efficiency on the reduction of nitrate leaching, we propose an approach based on the combined use of production and pollution functions to derive the impacts on the expected farmer response of these instruments. Some of the most important factors influencing nitrate leaching and crop yield are the type of soil and the climatic conditions. Crop yield and nitrate leaching responses to different soil and climatic conditions were classified by means of a cluster analysis, and crops located in different areas but with similar response were grouped for the analysis. We use a spatial economic optimization model to evaluate the potential of taxes on nitrogen fertilizers, water prices, and taxes on nitrate emissions to reduce nitrate pollution, as well as their economic impact in terms of social welfare and farmers' net benefits. The method was applied to the Mancha Oriental System (MOS) in Spain, a large area with different soil types and climatic conditions. We divided the study area into zones of homogeneous crop production and nitrate leaching properties. Results show spatially different responses of crop growth and nitrate leaching, proving how the cost-effectiveness of pollution control instruments is contingent upon the spatial heterogeneities of the problem. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. A note on monotonicity of item response functions for ordered polytomous item response theory models.

    Science.gov (United States)

    Kang, Hyeon-Ah; Su, Ya-Hui; Chang, Hua-Hua

    2018-03-08

    A monotone relationship between a true score (τ) and a latent trait level (θ) has been a key assumption for many psychometric applications. The monotonicity property in dichotomous response models is evident as a result of a transformation via a test characteristic curve. Monotonicity in polytomous models, in contrast, is not immediately obvious because item response functions are determined by a set of response category curves, which are conceivably non-monotonic in θ. The purpose of the present note is to demonstrate strict monotonicity in ordered polytomous item response models. Five models that are widely used in operational assessments are considered for proof: the generalized partial credit model (Muraki, 1992, Applied Psychological Measurement, 16, 159), the nominal model (Bock, 1972, Psychometrika, 37, 29), the partial credit model (Masters, 1982, Psychometrika, 47, 147), the rating scale model (Andrich, 1978, Psychometrika, 43, 561), and the graded response model (Samejima, 1972, A general model for free-response data (Psychometric Monograph no. 18). Psychometric Society, Richmond). The study asserts that the item response functions in these models strictly increase in θ and thus there exists strict monotonicity between τ and θ under certain specified conditions. This conclusion validates the practice of customarily using τ in place of θ in applied settings and provides theoretical grounds for one-to-one transformations between the two scales. © 2018 The British Psychological Society.

  16. 99Tc atom counting by quadrupole ICP-MS. Optimisation of the instrumental response

    International Nuclear Information System (INIS)

    Mas, Jose L.; Garcia-Leon, Manuel; Bolivar, Juan P.

    2002-01-01

    In this paper, an extensive work is done on the specific tune of a conventional ICP-MS for 99 Tc atom counting. For this, two methods have been used and compared: the partial variable control method and the 5D Simplex method. Instrumental limits of detection of 0.2 and 0.8 ppt, respectively, were obtained. They are noticeably lower than that found with the automatic tune method of the spectrometer, 47 ppt, which shows the need of a specific tune when very low levels of 99 Tc have to be determined. A study is presented on the mass interferences for 99 Tc. Our experiments show that the formation of polyatomic atoms or refractory oxides as well as 98 Mo hydrides seem to be irrelevant for 99 Tc atom counting. The opposite occurs with the presence of isobaric interferences, i.e. 99 Ru, and the effect of abundance sensitivity, or low-mass resolution, which can modify the response at m/z=99 to a non-negligible extent

  17. Modification of response functions of cat visual cortical cells by spatially congruent perturbing stimuli.

    Science.gov (United States)

    Kabara, J F; Bonds, A B

    2001-12-01

    Responses of cat striate cortical cells to a drifting sinusoidal grating were modified by the superimposition of a second, perturbing grating (PG) that did not excite the cell when presented alone. One consequence of the presence of a PG was a shift in the tuning curves. The orientation tuning of all 41 cells exposed to a PG and the spatial frequency tuning of 83% of the 23 cells exposed to a PG showed statistically significant dislocations of both the response function peak and center of mass from their single grating values. As found in earlier reports, the presence of PGs suppressed responsiveness. However, reductions measured at the single grating optimum orientation or spatial frequency were on average 1.3 times greater than the suppression found at the peak of the response function modified by the presence of the PG. Much of the loss in response seen at the single grating optimum is thus a result of a shift in the tuning function rather than outright suppression. On average orientation shifts were repulsive and proportional (approximately 0.10 deg/deg) to the angle between the perturbing stimulus and the optimum single grating orientation. Shifts in the spatial frequency response function were both attractive and repulsive, resulting in an overall average of zero. For both simple and complex cells, PGs generally broadened orientation response function bandwidths. Similarly, complex cell spatial frequency response function bandwidths broadened. Simple cell spatial frequency response functions usually did not change, and those that did broadened only 4% on average. These data support the hypothesis that additional sinusoidal components in compound stimuli retune cells' response functions for orientation and spatial frequency.

  18. Validation study of a web-based assessment of functional recovery after radical prostatectomy

    Directory of Open Access Journals (Sweden)

    Vickers Andrew J

    2010-08-01

    Full Text Available Abstract Background Good clinical care of prostate cancer patients after radical prostatectomy depends on careful assessment of post-operative morbidities, yet physicians do not always judge patient symptoms accurately. Logistical problems associated with using paper questionnaire limit their use in the clinic. We have implemented a web-interface ("STAR" for patient-reported outcomes after radical prostatectomy. Methods We analyzed data on the first 9 months of clinical implementation to evaluate the validity of the STAR questionnaire to assess functional outcomes following radical prostatectomy. We assessed response rate, internal consistency within domains, and the association between survey responses and known predictors of sexual and urinary function, including age, time from surgery, nerve sparing status and co-morbidities. Results Of 1581 men sent an invitation to complete the instrument online, 1235 responded for a response rate of 78%. Cronbach's alpha was 0.84, 0.86 and 0.97 for bowel, urinary and sexual function respectively. All known predictors of sexual and urinary function were significantly associated with survey responses in the hypothesized direction. Conclusions We have found that web-based assessment of functional recovery after radical prostatectomy is practical and feasible. The instrument demonstrated excellent psychometric properties, suggested that validity is maintained when questions are transferred from paper to electronic format and when patients give responses that they know will be seen by their doctor and added to their clinic record. As such, our system allows ready implementation of patient-reported outcomes into routine clinical practice.

  19. Polyester textile functionalization through incorporation of pH/thermo-responsive microgels. Part II: polyester functionalization and characterization

    NARCIS (Netherlands)

    Glampedaki, P.; Calvimontes, A.; Dutschk, Victoria; Warmoeskerken, Marinus

    2012-01-01

    A new approach to functionalize the surface of polyester textiles is described in this study. Functionalization was achieved by incorporating pH/temperature-responsive polyelectrolyte microgels into the textile surface layer using UV irradiation. The aim of functionalization was to regulate

  20. Transcription Factor Functional Protein-Protein Interactions in Plant Defense Responses

    Directory of Open Access Journals (Sweden)

    Murilo S. Alves

    2014-03-01

    Full Text Available Responses to biotic stress in plants lead to dramatic reprogramming of gene expression, favoring stress responses at the expense of normal cellular functions. Transcription factors are master regulators of gene expression at the transcriptional level, and controlling the activity of these factors alters the transcriptome of the plant, leading to metabolic and phenotypic changes in response to stress. The functional analysis of interactions between transcription factors and other proteins is very important for elucidating the role of these transcriptional regulators in different signaling cascades. In this review, we present an overview of protein-protein interactions for the six major families of transcription factors involved in plant defense: basic leucine zipper containing domain proteins (bZIP, amino-acid sequence WRKYGQK (WRKY, myelocytomatosis related proteins (MYC, myeloblastosis related proteins (MYB, APETALA2/ ETHYLENE-RESPONSIVE ELEMENT BINDING FACTORS (AP2/EREBP and no apical meristem (NAM, Arabidopsis transcription activation factor (ATAF, and cup-shaped cotyledon (CUC (NAC. We describe the interaction partners of these transcription factors as molecular responses during pathogen attack and the key components of signal transduction pathways that take place during plant defense responses. These interactions determine the activation or repression of response pathways and are crucial to understanding the regulatory networks that modulate plant defense responses.

  1. Predicted summary of panel discussion on smart instruments

    International Nuclear Information System (INIS)

    Sorber, R.E.

    1991-01-01

    The following is a hypothetical account of a panel discussion on Smart Instruments. It enumerates topics that are likely to covered in the actual discussion. A smart instrument may be defined as one that performs smart functions or as one that contains a computer of some sort. Neither definition is perfect. Smart functions might include, but are not limited to: automated data logging (reading, location, time); transfer (downloading) logged data to outside computer; computer assisted, remote calibration; linearity and dead time correction; performance trending; self diagnosis of faults; detector probe recognition; automated beta factor application; and automatic range selection. These smart functions are discussed

  2. Long-term memory for instrumental responses does not undergo protein synthesis-dependent reconsolidation upon retrieval.

    Science.gov (United States)

    Hernandez, Pepe J; Kelley, Ann E

    2004-01-01

    Recent evidence indicates that certain forms of memory, upon recall, may return to a labile state requiring the synthesis of new proteins in order to preserve or reconsolidate the original memory trace. While the initial consolidation of "instrumental memories" has been shown to require de novo protein synthesis in the nucleus accumbens, it is not known whether memories of this type undergo protein synthesis-dependent reconsolidation. Here we show that low doses of the protein synthesis inhibitor anisomycin (ANI; 5 or 20 mg/kg) administered systemically in rats immediately after recall of a lever-pressing task potently impaired performance on the following daily test sessions. We determined that the nature of this impairment was attributable to conditioned taste aversion (CTA) to the sugar reinforcer used in the task rather than to mnemonic or motoric impairments. However, by substituting a novel flavored reinforcer (chocolate pellets) prior to the administration of doses of ANI (150 or 210 mg/kg) previously shown to cause amnesia, a strong CTA to chocolate was induced sparing any aversion to sugar. Importantly, when sugar was reintroduced on the following session, we found that memory for the task was not significantly affected by ANI. Thus, these data suggest that memory for a well-learned instrumental response does not require protein synthesis-dependent reconsolidation as a means of long-term maintenance.

  3. Instrument to collect fogwater for chemical analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jacob, D.J.; Waldman, J.M.; Haghi, M.; Hoffmann, M.R.; Flagan, R.C.

    1985-06-01

    An instrument is presented which collects large samples of ambient fogwater by impaction of droplets on a screen. The collection efficiency of the instrument is determined as a function of droplet size, and it is shown that fog droplets in the range 3--100-..mu..m diameter are efficiently collected. No significant evaporation or condensation occurs at any stage of the collection process. Field testing indicates that samples collected are representative of the ambient fogwater. The instrument may easily be automated, and is suitable for use in routine air quality monitoring programs.

  4. Instrument to collect fogwater for chemical analysis

    Science.gov (United States)

    Jacob, Daniel J.; Waldman, Jed M.; Haghi, Mehrdad; Hoffmann, Michael R.; Flagan, Richard C.

    1985-06-01

    An instrument is presented which collects large samples of ambient fogwater by impaction of droplets on a screen. The collection efficiency of the instrument is determined as a function of droplet size, and it is shown that fog droplets in the range 3-100-μm diameter are efficiently collected. No significant evaporation or condensation occurs at any stage of the collection process. Field testing indicates that samples collected are representative of the ambient fogwater. The instrument may easily be automated, and is suitable for use in routine air quality monitoring programs.

  5. Comparison of Two Methodologies for Calibrating Satellite Instruments in the Visible and Near-Infrared

    Science.gov (United States)

    Barnes, Robert A.; Brown, Steven W.; Lykke, Keith R.; Guenther, Bruce; Butler, James J.; Schwarting, Thomas; Turpie, Kevin; Moyer, David; DeLuccia, Frank; Moeller, Christopher

    2015-01-01

    Traditionally, satellite instruments that measure Earth-reflected solar radiation in the visible and near infrared wavelength regions have been calibrated for radiance responsivity in a two-step method. In the first step, the relative spectral response (RSR) of the instrument is determined using a nearly monochromatic light source such as a lamp-illuminated monochromator. These sources do not typically fill the field-of-view of the instrument nor act as calibrated sources of light. Consequently, they only provide a relative (not absolute) spectral response for the instrument. In the second step, the instrument views a calibrated source of broadband light, such as a lamp-illuminated integrating sphere. The RSR and the sphere absolute spectral radiance are combined to determine the absolute spectral radiance responsivity (ASR) of the instrument. More recently, a full-aperture absolute calibration approach using widely tunable monochromatic lasers has been developed. Using these sources, the ASR of an instrument can be determined in a single step on a wavelength-by-wavelength basis. From these monochromatic ASRs, the responses of the instrument bands to broadband radiance sources can be calculated directly, eliminating the need for calibrated broadband light sources such as lamp-illuminated integrating spheres. In this work, the traditional broadband source-based calibration of the Suomi National Preparatory Project (SNPP) Visible Infrared Imaging Radiometer Suite (VIIRS) sensor is compared with the laser-based calibration of the sensor. Finally, the impact of the new full-aperture laser-based calibration approach on the on-orbit performance of the sensor is considered.

  6. 脑性瘫痪患儿踝足矫形器配戴前后对运动功能的量化评价%Quantitative assessment of motor function on children with cerebral palsy before and after wearing ankle foot orthopedic instruments

    Institute of Scientific and Technical Information of China (English)

    李润洁

    2002-01-01

    Objective To assess motor function quantitatively on children with cerebral palsy before and after wearing ankle foot orthopedic instruments.Method Ankle foot orthopedic instruments were made by Dalian Prosthesis Factory.Children' motor function was assessed with self made quantitative assessment scale according to the forth,fifth function area of motor assessment scale of children with cerebral palsy after one week of wearing orthopedic instruments. Result In all 23 patients, orthopedic instruments proved effective in controlling leg muscular tension,correcting equines,genu recurvatum,talips valgus and talipes varus,keeping erect posture and modifying gait.Motor function assessed show significant difference before and one week after wearing orthopedic instruments (P< 0.001).Conclusion Ankle foot orthopedic instruments play a positive role in improving motor function of lower extremity in cerebral palsy patients.

  7. Reactor instrumentation and control

    International Nuclear Information System (INIS)

    Wach, D.; Beraha, D.

    1980-01-01

    The methods for measuring radiation are shortly reviewed. The instrumentation for neutron flux measurement is classified into out-of-core and in-core instrumentation. The out-of-core instrumentation monitors the operational range from the subcritical reactor to full power. This large range is covered by several measurement channels which derive their signals from counter tubes and ionization chambers. The in-core instrumentation provides more detailed information on the power distribution in the core. The self-powered neutron detectors and the aeroball system in PWR reactors are discussed. Temperature and pressure measurement devices are briefly discussed. The different methods for leak detection are described. In concluding the plant instrumentation part some new monitoring systems and analysis methods are presented: early failure detection methods by noise analysis, acoustic monitoring and vibration monitoring. The presentation of the control starts from an qualitative assessment of the reactor dynamics. The chosen control strategy leads to the definition of the part-load diagram, which provides the set-points for the different control systems. The tasks and the functions of these control systems are described. In additiion to the control, a number of limiting systems is employed to keep the reactor in a safe operating region. Finally, an outlook is given on future developments in control, concerning mainly the increased application of process computers. (orig./RW)

  8. THE ASYLUM, BETWEEN HUMANITARIAN RESPONSE AND POLITICAL INSTRUMENT

    Directory of Open Access Journals (Sweden)

    CATRINEL BRUMAR

    2012-05-01

    Full Text Available At 9 November 2010, the European Court of Justice, in a preliminary ruling, decided to depart from the interpretation promoted by the United Nations High Commissioner for Refugees, in the matter of the application of the exclusion clauses. The European Court considered that no proportionality test between human rights protection and gravity of a crime is to be applied in the case of a person suspected of having committed an act contrary to the principles and purposes of the United Nations. By eliminating this test, the Court is sending a signal on rethinking the asylum institution, from a humanitarian tool that it became, to a political instrument. This decision could not be read alone; corroborated to the concerns already raised on the suitable use of the asylum instrument to address massive humanitarian needs, it would indicate a reorientation in the interpretation of international norms governing the refugee law. Still, the human rights organs and the European Court of Human Rights continue to refer to the asylum as a situation where a humanitarian perspective, reflected in the proportionality test, or for those mechanisms the risk of human rights violation probability test, is still valid. The two apparently divergent directions will need to converge in the implementation of the European Union regulations on asylum. This paper is exploring the possible reinterpretation of the European norms, trying to identify the new trends in the political perspective of asylum and the limitations to these trends that the respect for human rights is establishing.

  9. Can Reliability of Multiple Component Measuring Instruments Depend on Response Option Presentation Mode?

    Science.gov (United States)

    Menold, Natalja; Raykov, Tenko

    2016-01-01

    This article examines the possible dependency of composite reliability on presentation format of the elements of a multi-item measuring instrument. Using empirical data and a recent method for interval estimation of group differences in reliability, we demonstrate that the reliability of an instrument need not be the same when polarity of the…

  10. De Gross Motor Function Measure (GMFM): een onderzoek naar de betrouwbaarheid van de Nederlandse vertaling.

    NARCIS (Netherlands)

    Veenhof, C.; Ketelaar, M.; Petegem-van Beek, E. van

    2003-01-01

    This article is about the psychometric characteristics of the Dutch translation of the Gross Motor Function Measure (GMFM). It describes the reliability of the instrument. The article "Gross Motor Function Measure" (GMFM): a validity study of the Dutch translation focusses on the responsiveness of

  11. Response function of a p type - HPGe detector

    International Nuclear Information System (INIS)

    Lopez-Pino, Neivy; Cabral, Fatima Padilla; D'Alessandro, Katia; Maidana, Nora Lia; Vanin, Vito Roberto

    2011-01-01

    The response function of a HPGe detector depends on Ge crystal dimensions and dead layers thicknesses; most of them are not given by the manufacturers or change with detector damage from neutrons or contact with the atmosphere and therefore must be experimentally determined. The response function is obtained by a Monte-Carlo simulation procedure based on the Ge crystal characteristics. In this work, a p-type coaxial HPGe detector with 30% efficiency, manufactured in 1989, was investigated. The crystal radius and length and the inner hole dimensions were obtained scanning the capsule both in the radial and axial directions using 4 mm collimated beams from 137 Cs, 207 Bi point sources placed on a x-y table in steps of 2,00 mm. These dimensions were estimated comparing the experimental peak areas with those obtained by simulation using several hole configurations. In a similar procedure, the frontal dead layer thickness was determined using 2 mm collimated beams of the 59 keV gamma-rays from 241 Am and 81 keV from 133 Ba sources hitting the detector at 90 deg and 45 deg with respect to the capsule surface. The Monte Carlo detector model included, besides the crystal, hole and capsules sizes, the Ge dead-layers. The obtained spectra were folded with a gaussian resolution function to account for electronic noise. The comparison of simulated and experimental response functions for 4 mm collimated beams of 60 Co, 137 Cs, and 207 Bi points sources placed at distances of 7, 11 and 17 cm from the detector end cap showed relative deviations of about 10% in general and below 10% in the peak. The frontal dead layer thickness determined by our procedure was different from that specified by the detector manufacturer. (author)

  12. Development and validation of an instrument to predict functional recovery in tibial fracture patients: the somatic pre-occupation and coping (SPOC) questionnaire

    NARCIS (Netherlands)

    Busse, Jason W.; Bhandari, Mohit; Guyatt, Gordon H.; Heels-Ansdell, Diane; Kulkarni, Abhaya V.; Mandel, Scott; Sanders, David; Schemitsch, Emil; Swiontkowski, Mark; Tornetta, Paul; Wai, Eugene; Walter, Stephen D.; Guyatt, Gordon; Sanders, David W.; Schemitsch, Emil H.; Swiontkowski, Marc; Walter, Stephen; Sprague, Sheila; Buckingham, Lisa; Leece, Pamela; Viveiros, Helena; Mignott, Tashay; Ansell, Natalie; Sidorkewicz, Natalie; Agel, Julie; Bombardier, Claire; Berlin, Jesse A.; Bosse, Michael; Browner, Bruce; Gillespie, Brenda; Jones, Alan; O'Brien, Peter; Poolman, Rudolf; Macleod, Mark D.; Carey, Timothy; Leitch, Kellie; Bailey, Stuart; Gurr, Kevin; Bartha, Charlene; Low, Isolina; MacBean, Leila V.; Ramu, Mala; Reiber, Susan; Strapp, Ruth; Goslings, J. Carel; Ponsen, Kees Jan; Luitse, Jan; Kloen, Peter; Joosse, Pieter; Winkelhagen, Jasper

    2012-01-01

    To explore the role of patients' beliefs in their likelihood of recovery from severe physical trauma. We developed and validated an instrument designed to capture the impact of patients' beliefs on functional recovery from injury: the Somatic Pre-Occupation and Coping (SPOC) questionnaire. At

  13. Application of instrumented nanoindentation in preformulation studies of pharmaceutical active ingredients and excipients

    Directory of Open Access Journals (Sweden)

    Egart Mateja

    2016-09-01

    Full Text Available Nanoindentation allows quantitative determination of a material’s response to stress such as elastic and plastic deformation or fracture tendency. Key instruments that have enabled great advances in nanomechanical studies are the instrumented nanoindenter and atomic force microscopy. The versatility of these instruments lies in their capability to measure local mechanical response, in very small volumes and depths, while monitoring time, displacement and force with high accuracy and precision.

  14. Technical presentation - KEITHLEY Instruments - CANCELLED

    CERN Multimedia

    FI Department

    2009-01-01

    10 March 2009 13:30 – 15:30, Council Chamber, Bldg. 503 Keithley markets highly accurate instruments and data acquisition products, as well as complete system solutions for high-volume production and assembly testing. Keithley Instruments, Inc. designs, develops, manufactures and markets complex electronic instruments and systems geared to the specialized needs of electronics manufacturers for high-performance production testing, process monitoring, product development and research. Products and Services: Digital Multimeters and Data Acquisition Systems Current / Voltage Source and Measure Products Low Current / High Resistance Measurement Products Function/Pulse/Arbitrary/Pattern Generators Low Voltage/Low Resistance Measurement Products RF Spectrum Analyzer / RF Signal Generator / RF Switching Semiconductor Device Characterization Program: Topic 1: Welcome and short overview of new Products SMU 26XXA / ARB Generator 3390 / DMM 3706 / E-Meter 6517B Topic 2a: Te...

  15. A fundamental role for context in instrumental learning and extinction.

    Science.gov (United States)

    Bouton, Mark E; Todd, Travis P

    2014-05-01

    The purpose of this article is to review recent research that has investigated the effects of context change on instrumental (operant) learning. The first part of the article discusses instrumental extinction, in which the strength of a reinforced instrumental behavior declines when reinforcers are withdrawn. The results suggest that extinction of either simple or discriminated operant behavior is relatively specific to the context in which it is learned: As in prior studies of Pavlovian extinction, ABA, ABC, and AAB renewal effects can all be observed. Further analysis supports the idea that the organism learns to refrain from making a specific response in a specific context, or in more formal terms, an inhibitory context-response association. The second part of the article then discusses research suggesting that the context also controls instrumental behavior before it is extinguished. Several experiments demonstrate that a context switch after either simple or discriminated operant training causes a decrement in the strength of the response. Over a range of conditions, the animal appears to learn a direct association between the context and the response. Under some conditions, it can also learn a hierarchical representation of context and the response-reinforcer relation. Extinction is still more context-specific than conditioning, as indicated by ABC and AAB renewal. Overall, the results establish that the context can play a significant role in both the acquisition and extinction of operant behavior. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. EPRTM Reactor neutron instrumentation

    International Nuclear Information System (INIS)

    Pfeiffer, Maxime; SALA, Stephanie

    2013-06-01

    The core safety during operation is linked, in particular, to the respect of criteria related to the heat generated in fuel rods and to the heat exchange between the rods and the coolant. This local power information is linked to the power distribution in the core. In order to evaluate the core power distribution, the EPR TM reactor relies on several types of neutron detectors: - ionization chambers located outside the vessel and used for protection and monitoring - a fixed in-core instrumentation based on Cobalt Self Powered Neutron Detectors used for protection and monitoring - a mobile reference in-core instrumentation based on Vanadium aero-balls This document provides a description of this instrumentation and its use in core protection, limitation, monitoring and control functions. In particular, a description of the detectors and the principles of their signal generation is supplied as well as the description of the treatments related to these detectors in the EPR TM reactor I and C systems (including periodical calibration). (authors)

  17. Responsiveness of the OARSI-OMERACT osteoarthritis pain and function measures

    DEFF Research Database (Denmark)

    Bond, M; Davis, A; Lohmander, Stefan

    2012-01-01

    To assess the responsiveness of the Intermittent and Constant Osteoarthritis Pain (ICOAP) measure, Hip Disability and Osteoarthritis Outcome Score Physical Function Short Form (HOOS-PS), and the Knee Disability and Osteoarthritis Outcome Score Physical Function Short Form (KOOS-PS) in a pharmacol...

  18. Handbook on care, handling and protection of nuclear medicine instruments

    International Nuclear Information System (INIS)

    2000-11-01

    Instruments are fundamental to successful nuclear medicine practice. They must be properly installed in an environment in which they can give accurate and uninterrupted service. They have to be properly and carefully operated and supported throughout their life by regular care and maintenance. If something is wrong with a key instrument all well trained staff members are idle and all purchased radiopharmaceuticals become useless. Overall responsibility for instrumentation rests with the directors of nuclear medicine centres. They should support their electronic engineers, medical physicists, technologists and physicians to plan and implement the care and protection of nuclear medicine instruments, see that they are properly maintained, and kept in optimum working condition by regular checks. Protection should be considered, and provided for, before installing any new instrument. The protective devices are part of the new installation and should be well maintained along with the instrument throughout its life. Thus protection needs careful planning, particularly at the beginning of a new instrumentation programme. It can affect selection, procurement, acceptance testing, and the design of quality control and maintenance routines. These activities should be considered as important in their own right. They should not be mixed in with other functions or left to take care of themselves in the daily rush to get through routine work. Experience suggests that more than half of all failures of electronic equipment are due to damage by external electrical disturbances. Section 2 of this handbook aims to help instrument users in nuclear medicine centres to understand the nature of the various types of disturbance, and to protect against them. Section 3 shows how air conditioning can help to protect instrumentation. Section 4 lists some practical tips to avoid accidental damage due to mishandling. A computer program for use with Personal Computers, ''EPC Expert'' is described

  19. Cross-cultural adaptation and validation of a Brazilian version of an instrument to assess impairments related to oral functioning of people with Down syndrome

    Directory of Open Access Journals (Sweden)

    Bonanato Karina

    2013-01-01

    Full Text Available Abstract Background An instrument was developed in Canada to assess impairments related to oral functioning of individuals with four years of age or older with Down syndrome (DS. The present study attempted to carry out the cross-cultural adaptation and validation of the instrument for the Brazilian Portuguese language and to test its reliability and validity. Findings After translation and cross-cultural adaptation, the instrument was tested on caregivers of people with DS. Clinical examination for malocclusion was carried out in people with DS by two calibrated examiners. Inter and Intra examiner agreement was assessed by Intraclass Correlation Coefficient (ICC and ranged from 0.92 to 0.97 respectively. Total of 157 people with DS and their caregivers were able to compose the sample. They were selected from eight institutions for people with DS in five cities of southeastern Brazil. The mean age of people with DS was 20.7 [±13.1] and for caregivers was 53.1 [±13.7]. The mean instrument score was 18.6 [±9.0]. Internal reliability ranged from 0.49 to 0.80 and external reliability ranged from 0.78 to 0.88. Construct validity was verified by significant correlations identified between malocclusion and the total instrument; and caregivers’ educational level and the instrument (p Conclusions Initial validity tests indicated that the instrument related to the oral health for people with DS may be a valid instrument to this segment of the population in Brazil.

  20. A predator-prey model with a holling type I functional response including a predator mutual interference

    Science.gov (United States)

    Seo, G.; DeAngelis, D.L.

    2011-01-01

    The most widely used functional response in describing predator-prey relationships is the Holling type II functional response, where per capita predation is a smooth, increasing, and saturating function of prey density. Beddington and DeAngelis modified the Holling type II response to include interference of predators that increases with predator density. Here we introduce a predator-interference term into a Holling type I functional response. We explain the ecological rationale for the response and note that the phase plane configuration of the predator and prey isoclines differs greatly from that of the Beddington-DeAngelis response; for example, in having three possible interior equilibria rather than one. In fact, this new functional response seems to be quite unique. We used analytical and numerical methods to show that the resulting system shows a much richer dynamical behavior than the Beddington-DeAngelis response, or other typically used functional responses. For example, cyclic-fold, saddle-fold, homoclinic saddle connection, and multiple crossing bifurcations can all occur. We then use a smooth approximation to the Holling type I functional response with predator mutual interference to show that these dynamical properties do not result from the lack of smoothness, but rather from subtle differences in the functional responses. ?? 2011 Springer Science+Business Media, LLC.

  1. Triggering Avoidance: Dissociable Influences of Aversive Pavlovian Conditioned Stimuli on Human Instrumental Behavior.

    Science.gov (United States)

    Garofalo, Sara; Robbins, Trevor W

    2017-01-01

    The present study investigates human aversive Pavlovian-to-Instrumental Transfer (PIT) and possible influences of outcome devaluation and instrumental overtraining on this effect. PIT measures the extent to which a Pavlovian conditioned stimulus (CS) can increase instrumental responses independently paired with the same (outcome-specific transfer) or a different (general transfer) reinforcer. Two measures of PIT were obtained: the percentage of instrumental responses and the vigor of such responses. Thirty-eight volunteers performed a standard PIT task sequence. Results showed a double dissociation between outcome-specific and general transfer: the first selectively expressed in the amount of responses, the second in the vigor measure solely. Furthermore, outcome-specific transfer was enhanced by overtraining, but not affected by devaluation. General transfer, on the other hand, was affected by neither overtraining, nor devaluation. A positive correlation between general transfer and sensitivity to punishments was found. Findings are discussed in terms of hypothetically different underlying neurobehavioral mechanisms and their relations to habits and goal-directed behavior.

  2. Intelligent type sodium instrumentations for LMFR

    International Nuclear Information System (INIS)

    Daolong Chen

    1996-01-01

    The constructions and their performances of a lot of newly developed intelligent type sodium instrumentations that consist of the intelligent type sodium flowmeter, the intelligent type immersed sodium flowmeter, the intelligent type sodium manometer and the intelligent type sodium level gauge are described. The graduation characteristic equations for corresponding transducer using the medium temperature as the parameter are given. Because the operating temperature limit of measured medium (sodium) is wide, so the on-line compensation of the temperature effect of their graduation characteristics much be considered. The tests show that these intelligent type sodium instrumentations possess of good linearity. The accurate sodium process parameter (flowrate, pressure and level) measurement data can be obtained by means of their on-line compensation function of the temperature effect. Moreover, these intelligent type sodium instrumentations possess of the self-inspection, the electric shutoff protection, the setting of full-scale, the setting of alarm limits (two upper limits and two lower limits alarms), the thermocouple breaking alarm, each other isolative the 0-10V direct-current analogue output and CENTRONICS standard digital output, and the alarm relay contact output. These intelligent type sodium instrumentations are suitable particularly for the instrument, control and protective systems of LMFR by means of these excellent functions based on microprocessor. The basic error of the intelligent type sodium flowmeter, immersed sodium flowmeter, sodium manometer and sodium level gauge is respectively ±2%, ±2.3%, ±0.3% and ±1.9% of measuring range. (author). 4 refs, 9 figs

  3. Thermo-responsive polymer-functionalized mesoporous carbon for controlled drug release

    Energy Technology Data Exchange (ETDEWEB)

    Zhu Shenmin, E-mail: smzhu@sjtu.edu.cn [State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240 (China); Chen Chenxin [State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240 (China); Chen Zhixin [Faculty of Engineering, University of Wollongong, Wollongong, NSW 2522 (Australia); Liu Xinye; Li Yao; Shi Yang; Zhang Di [State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240 (China)

    2011-03-15

    Research highlights: {yields} A responsive drug delivery system based on poly(N-isopropyl acrylamide) (PNIPAM) functionalized ordered mesoporous carbon (CMK-3) is developed. {yields} A combination of surface modification of CMK-3 and in situ internal polymerization of PNIPAM was used. {yields} The system exhibited a pronounced transition at around 20-25 deg. C. - Abstract: A novel responsive drug delivery system based on poly(N-isopropyl acrylamide) (PNIPAM) functionalized ordered mesoporous carbon (CMK-3) is developed. The polymer-functionalized CMK-3 was obtained by a combination of simple surface modification of CMK-3 and in situ internal polymerization of PNIPAM. The formation of the PNIPAM inside the CMK-3 was confirmed by thermal gravimetric analysis, Fourier transform-infrared spectroscopy, scanning and transmission electron microscopy and N{sub 2} adsorption/desorption measurements. Controlled drug release tests through the porous network of the PNIPAM functionalized CMK-3 were carried out by measuring the uptake and release of ibuprofen in vitro. The release profiles exhibited a pronounced transition at around 20-25 deg. C. This thermo-sensitive release property of this delivery system was further confirmed by temperature-variable hydrogen nuclear magnetic resonance analysis. The internal PNIPAM layers acted as a storage gate as well as a release switch in response to the stimuli of environment.

  4. Fitting of transfer functions to frequency response measurements

    International Nuclear Information System (INIS)

    Moret, J.M.

    1994-12-01

    An algorithm for approximating a given complex frequency response with a rational function of two polynomials with real coefficients is presented, together with its extension to distributed parameter systems, the corresponding error analysis and its application to a real case. (author) 5 figs., 4 refs

  5. The introduction of radiation monitor produced by several nuclear instrument factories

    International Nuclear Information System (INIS)

    Yu Liying

    2005-01-01

    The paper introduce some radiation monitor products of several nuclear instrument factories include Xi'an Nuclear Instrument Factory, MGP Instruments Inc, and Canberra Industries Inc. The introduction aspects include the range, configuration, and application of products. So, the paper is reference for the designer with responsibility for radiation monitoring system of new nuclear project. (authors)

  6. On the Measurement of Power Law Creep Parameters from Instrumented Indentation

    Science.gov (United States)

    Sudharshan Phani, P.; Oliver, W. C.; Pharr, G. M.

    2017-11-01

    Recently the measurement of the creep response of materials at small scales has received renewed interest largely because the equipment required to perform high-temperature nanomechanical testing has become available to an increasing number of researchers. Despite that increased access, there remain several significant experimental and modeling challenges in small-scale mechanical testing at elevated temperatures that are as yet unresolved. In this regard, relating the creep response observed with high-temperature instrumented indentation experiments to macroscopic uniaxial creep response is of great practical value. In this review, we present an overview of various methods currently being used to measure creep with instrumented indentation, with a focus on geometrically self-similar indenters, and their relative merits and demerits from an experimental perspective. A comparison of the various methods to use those instrumented indentation results to predict the uniaxial power law creep response of a wide range of materials will be presented to assess their validity.

  7. Instruments Measuring Integrated Care: A Systematic Review of Measurement Properties.

    Science.gov (United States)

    Bautista, Mary Ann C; Nurjono, Milawaty; Lim, Yee Wei; Dessers, Ezra; Vrijhoef, Hubertus Jm

    2016-12-01

    -centered care (49%); fewer studies measured care continuity/comprehensive care (15%) and care coordination/case management (3%). We mapped 84% of the measured constructs to the clinical integration domain of the RMIC, with fewer constructs related to the domains of professional (3.7%), organizational (3.4%), and functional (0.5%) integration. Only 8% of the instruments were mapped to a combination of domains; none were mapped exclusively to the system or normative integration domains. The majority of instruments were administered to either patients (60%) or health care providers (20%). Of the measurement properties, responsiveness (4%), measurement error (7%), and criterion (12%) and cross-cultural validity (14%) were less commonly reported. We found measurement properties. Only a minority of index instruments showed strong evidence of positive findings for internal consistency (15%), content validity (19%), and structural validity (7%); with moderate evidence of positive findings for internal consistency (14%) and construct validity (14%). Our results suggest that the quality of measurement properties of instruments measuring integrated care is in need of improvement with the less-studied constructs and domains to become part of newly developed instruments. © 2016 Milbank Memorial Fund.

  8. Instruments Measuring Integrated Care: A Systematic Review of Measurement Properties

    Science.gov (United States)

    BAUTISTA, MARY ANN C.; NURJONO, MILAWATY; DESSERS, EZRA; VRIJHOEF, HUBERTUS JM

    2016-01-01

    integration (33%) and patient‐centered care (49%); fewer studies measured care continuity/comprehensive care (15%) and care coordination/case management (3%). We mapped 84% of the measured constructs to the clinical integration domain of the RMIC, with fewer constructs related to the domains of professional (3.7%), organizational (3.4%), and functional (0.5%) integration. Only 8% of the instruments were mapped to a combination of domains; none were mapped exclusively to the system or normative integration domains. The majority of instruments were administered to either patients (60%) or health care providers (20%). Of the measurement properties, responsiveness (4%), measurement error (7%), and criterion (12%) and cross‐cultural validity (14%) were less commonly reported. We found measurement properties. Only a minority of index instruments showed strong evidence of positive findings for internal consistency (15%), content validity (19%), and structural validity (7%); with moderate evidence of positive findings for internal consistency (14%) and construct validity (14%). Conclusions Our results suggest that the quality of measurement properties of instruments measuring integrated care is in need of improvement with the less‐studied constructs and domains to become part of newly developed instruments. PMID:27995711

  9. Age-Related Changes in Bimanual Instrument Playing with Rhythmic Cueing

    Directory of Open Access Journals (Sweden)

    Soo Ji Kim

    2017-09-01

    Full Text Available Deficits in bimanual coordination of older adults have been demonstrated to significantly limit their functioning in daily life. As a bimanual sensorimotor task, instrument playing has great potential for motor and cognitive training in advanced age. While the process of matching a person’s repetitive movements to auditory rhythmic cueing during instrument playing was documented to involve motor and attentional control, investigation into whether the level of cognitive functioning influences the ability to rhythmically coordinate movement to an external beat in older populations is relatively limited. Therefore, the current study aimed to examine how timing accuracy during bimanual instrument playing with rhythmic cueing differed depending on the degree of participants’ cognitive aging. Twenty one young adults, 20 healthy older adults, and 17 older adults with mild dementia participated in this study. Each participant tapped an electronic drum in time to the rhythmic cueing provided using both hands simultaneously and in alternation. During bimanual instrument playing with rhythmic cueing, mean and variability of synchronization errors were measured and compared across the groups and the tempo of cueing during each type of tapping task. Correlations of such timing parameters with cognitive measures were also analyzed. The results showed that the group factor resulted in significant differences in the synchronization errors-related parameters. During bimanual tapping tasks, cognitive decline resulted in differences in synchronization errors between younger adults and older adults with mild dimentia. Also, in terms of variability of synchronization errors, younger adults showed significant differences in maintaining timing performance from older adults with and without mild dementia, which may be attributed to decreased processing time for bimanual coordination due to aging. Significant correlations were observed between variability of

  10. The determination of frequency response function of the RSG Gas by laplace transform analysis

    International Nuclear Information System (INIS)

    Tukiran, S.; Surian, P.; Jujuratisbela, U.

    1997-01-01

    The response function of the RSG-GAS reactor system to the reactivity perturbations is necessary to be analyzed due to the interrelation with reliability and safety of reactor operation. the response depends on the power frequency response function H(s), while H(s) depends on the zero power frequency response function Z(s) and dynamic power coefficient of reactivity Kp(s) determination of the frequency response function of the RSG-GAS reactor was done by Fourier transform analysis method. Z(s) was obtained by fourier transform of P(t) and Cj(t) became P(S) and Cj(s) in point kinetic equations. Second order of simpson rule was used for completion of its numerical integration. then. LYMPR (Laplace transform for multipurpose reactor) code was made with fortran 77 computer language in vax 8550 system. the LTMPR code is able to determine the frequency response function and period-reactivity relation of RSG-GAS reactor by rod drop method. Profile of power as rod drop, zero power (without reactivity feedback) was used for determination frequency response of RSG-GAS reactor. The results of calculations are in a good agreement with experiment result, so the LTMPR code can be used for analysis response frequency of the RSG-GAS reactor

  11. Construct validity of patient-reported outcome instruments in US adults with hemophilia: results from the Pain, Functional Impairment, and Quality of life (P-FiQ study

    Directory of Open Access Journals (Sweden)

    Batt K

    2017-08-01

    Full Text Available Katharine Batt,1 Michael Recht,2 David L Cooper,3 Neeraj N Iyer,3 Christine L Kempton4 1Hematology and Oncology, Wake Forest School of Medicine, Winston-Salem, NC, 2The Hemophilia Center, Oregon Health & Science University, Portland, OR, 3Novo Nordisk Inc., Plainsboro, NJ, 4Departments of Pediatrics and Hematology and Medical Oncology, Emory University School of Medicine, Atlanta, GA, USA Background: People with hemophilia (PWH experience frequent joint bleeding, resulting in pain and functional impairment. Generic and disease-specific patient-reported outcome (PRO instruments have been used in clinical studies, but rarely in the comprehensive hemophilia care setting. Objective: The objective of this study was to assess construct validity of PRO instruments measuring pain, functional impairment, and health-related quality of life in US PWH with a history of joint pain/bleeding. Methods: Adult male PWH completed 4 PRO instruments (EQ-5D-5L with visual analog scale, Brief Pain Inventory v2 Short Form [BPI], SF-36v2, Hemophilia Activities List [HAL] and underwent a musculoskeletal examination (Hemophilia Joint Health Score v2.1 [HJHS]. Construct validity between index and domain scores was evaluated by Pearson product-moment correlation coefficient. Results: A total of 381 PWH were enrolled. EQ-5D-5L Mobility correlated with BPI, SF-36v2, and HAL domains related to pain, physical function, and activity of the lower extremities. EQ-5D-5L Self-Care correlated only with HAL Self-Care. EQ-5D-5L Usual Activities correlated with BPI Pain Interference and domains within SF-36v2 and HAL related to pain and physical function/activities (particularly those involving the lower extremities. EQ-5D-5L Pain/Discomfort correlated with Bodily Pain and Physical Summary on SF-36v2, HAL Overall Activity, and all BPI pain domains. EQ-5D-5L Anxiety/Depression correlated with social/emotional/mental aspects of SF-36v2. On BPI, most pain domains correlated with Bodily

  12. Predator-dependent functional response in wolves: from food limitation to surplus killing.

    Science.gov (United States)

    Zimmermann, Barbara; Sand, Håkan; Wabakken, Petter; Liberg, Olof; Andreassen, Harry Peter

    2015-01-01

    The functional response of a predator describes the change in per capita kill rate to changes in prey density. This response can be influenced by predator densities, giving a predator-dependent functional response. In social carnivores which defend a territory, kill rates also depend on the individual energetic requirements of group members and their contribution to the kill rate. This study aims to provide empirical data for the functional response of wolves Canis lupus to the highly managed moose Alces alces population in Scandinavia. We explored prey and predator dependence, and how the functional response relates to the energetic requirements of wolf packs. Winter kill rates of GPS-collared wolves and densities of cervids were estimated for a total of 22 study periods in 15 wolf territories. The adult wolves were identified as the individuals responsible for providing kills to the wolf pack, while pups could be described as inept hunters. The predator-dependent, asymptotic functional response models (i.e. Hassell-Varley type II and Crowley-Martin) performed best among a set of 23 competing linear, asymptotic and sigmoid models. Small wolf packs acquired >3 times as much moose biomass as required to sustain their field metabolic rate (FMR), even at relatively low moose abundances. Large packs (6-9 wolves) acquired less biomass than required in territories with low moose abundance. We suggest the surplus killing by small packs is a result of an optimal foraging strategy to consume only the most nutritious parts of easy accessible prey while avoiding the risk of being detected by humans. Food limitation may have a stabilizing effect on pack size in wolves, as supported by the observed negative relationship between body weight of pups and pack size. © 2014 The Authors. Journal of Animal Ecology published by John Wiley & Sons Ltd on behalf of British Ecological Society.

  13. The reliability, validity and responsiveness of the Thai version of Systemic Lupus Erythematosus Quality of Life (SLEQOL-TH) instrument.

    Science.gov (United States)

    Kasitanon, N; Wangkaew, S; Puntana, S; Sukitawut, W; Leong, K P; Louthrenoo, W

    2013-03-01

    The English version of the Systemic Lupus Erythematosus Quality of Life Questionnaire (SLEQOL) is a validated disease-specific quality of life instrument. The aim of this study was to evaluate the psychometric properties of the Thai version of the SLEQOL (SLEQOL-TH). Two independent translators translated the SLEQOL into Thai. The back translation of this version was performed by two other independent translators. The final version, SLEQOL-TH, was completed after resolving the discrepancies revealed by the back translation. One hundred and nine patients with SLE were enrolled to test the reliability, construct validity, floor and ceiling effects, and sensitivity to the changes of the SLEQOL-TH at six months. The differential item functioning (DIF) between the Thai and English versions was analyzed using the partial gamma. The internal consistency of the SLEQOL-TH was satisfactory with the overall Cronbach's alpha of 0.86. The test-retest reliability of the SLEQOL-TH was acceptable with the intra-class correlation coefficient of 0.86. Low correlations between the SLEQOL-TH and SLEDAI were observed. The total score of the SLEQOL-TH was moderately responsive to changes in quality of life, with a standardized response mean of 0.50. When comparing the SLEQOL-TH from Thai SLE patients with the original SLEQOL version obtained from Singapore SLE patients, 11 out of 40 items showed a moderate to large DIF. The SLEQOL-TH has acceptable psychometric properties and shows construct validity. In comparison with the English version of SLEQOL, there are some items that showed DIF. The applicability of the SLEQOL-TH in real-life clinical practice and clinical trials needs to be determined.

  14. Response of Korean pine's functional traits to geography and climate.

    Directory of Open Access Journals (Sweden)

    Yichen Dong

    Full Text Available This study analyzed the characteristics of Korean pine (Pinus koraiensis functional trait responses to geographic and climatic factors in the eastern region of Northeast China (41°-48°N and the linear relationships among Korean pine functional traits, to explore this species' adaptability and ecological regulation strategies under different environmental conditions. Korean pine samples were collected from eight sites located at different latitudes, and the following factors were determined for each site: geographic factors-latitude, longitude, and altitude; temperature factors-mean annual temperature (MAT, growth season mean temperature (GST, and mean temperature of the coldest month (MTCM; and moisture factors-annual precipitation (AP, growth season precipitation (GSP, and potential evapotranspiration (PET. The Korean pine functional traits examined were specific leaf area (SLA, leaf thickness (LT, leaf dry matter content (LDMC, specific root length (SRL, leaf nitrogen content (LNC, leaf phosphorus content (LPC, root nitrogen content (RNC, and root phosphorus content (RPC. The results showed that Korean pine functional traits were significantly correlated to latitude, altitude, GST, MTCM, AP, GSP, and PET. Among the Korean pine functional traits, SLA showed significant linear relationships with LT, LDMC, LNC, LPC, and RPC, and LT showed significant linear relationships with LDMC, SRL, LNC, LPC, RNC, and RPC; the linear relationships between LNC, LPC, RNC, and RPC were also significant. In conclusion, Korean pine functional trait responses to latitude resulted in its adaptation to geographic and climatic factors. The main limiting factors were precipitation and evapotranspiration, followed by altitude, latitude, GST, and MTCM. The impacts of longitude and MAT were not obvious. Changes in precipitation and temperature were most responsible for the close correlation among Korean pine functional traits, reflecting its adaption to habitat

  15. HPS instrument calibration laboratory accreditation program

    Energy Technology Data Exchange (ETDEWEB)

    Masse, F.X; Eisenhower, E.H.; Swinth, K.L.

    1993-12-31

    The purpose of this paper is to provide an accurate overview of the development and structure of the program established by the Health Physics Society (HPS) for accrediting instrument calibration laboratories relative to their ability to accurately calibrate portable health physics instrumentation. The purpose of the program is to provide radiation protection professionals more meaningful direct and indirect access to the National Institute of Standards and Technology (NIST) national standards, thus introducing a means for improving the uniformity, accuracy, and quality of ionizing radiation field measurements. The process is designed to recognize and document the continuing capability of each accredited laboratory to accurately perform instrument calibration. There is no intent to monitor the laboratory to the extent that each calibration can be guaranteed by the program; this responsibility rests solely with the accredited laboratory.

  16. Evaluation of fault-normal/fault-parallel directions rotated ground motions for response history analysis of an instrumented six-story building

    Science.gov (United States)

    Kalkan, Erol; Kwong, Neal S.

    2012-01-01

    According to regulatory building codes in United States (for example, 2010 California Building Code), at least two horizontal ground-motion components are required for three-dimensional (3D) response history analysis (RHA) of buildings. For sites within 5 km of an active fault, these records should be rotated to fault-normal/fault-parallel (FN/FP) directions, and two RHA analyses should be performed separately (when FN and then FP are aligned with the transverse direction of the structural axes). It is assumed that this approach will lead to two sets of responses that envelope the range of possible responses over all nonredundant rotation angles. This assumption is examined here using a 3D computer model of a six-story reinforced-concrete instrumented building subjected to an ensemble of bidirectional near-fault ground motions. Peak responses of engineering demand parameters (EDPs) were obtained for rotation angles ranging from 0° through 180° for evaluating the FN/FP directions. It is demonstrated that rotating ground motions to FN/FP directions (1) does not always lead to the maximum responses over all angles, (2) does not always envelope the range of possible responses, and (3) does not provide maximum responses for all EDPs simultaneously even if it provides a maximum response for a specific EDP.

  17. Study on response function of CdTe detector

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyunduk; Cho, Gyuseong [Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, Daejeon 305-701 (Korea, Republic of); Kang, Bo-Sun [Department of Radiological Science, Catholic University of Daegu, Kyoungsan, Kyoungbuk 712-702 (Korea, Republic of)], E-mail: bskang@cu.ac.kr

    2009-10-21

    So far the origin of the mechanism of light emission in the sonoluminescence has not elucidated whether it is due to blackbody radiation or bremsstrahlung. The final goal of our study is measuring X-ray energy spectrum using high-sensitivity cadmium telluride (CdTe) detector in order to obtain information for understanding sonoluminescence phenomena. However, the scope of this report is the measurement of X-ray spectrum using a high-resolution CdTe detector and determination of CdTe detector response function to obtain the corrected spectrum from measured soft X-ray source spectrum. In general, the measured spectrum was distorted by the characteristics of CdTe detector. Monte Carlo simulation code, MCNP, was used to obtain the reference response function of the CdTe detector. The X-ray spectra of {sup 57}Co, {sup 133}Ba, and {sup 241}Am were obtained by a 4x4x1.0(t) mm{sup 3} CdTe detector at room temperature.

  18. Development of an instrument to measure health center (HC) personnel's computer use, knowledge and functionality demand for HC computerized information system in Thailand.

    Science.gov (United States)

    Kijsanayotin, Boonchai; Pannarunothai, Supasit; Speedie, Stuart

    2005-01-01

    Knowledge about socio-technical aspects of information technology (IT) is vital for the success of health IT projects. The Thailand health administration anticipates using health IT to support the recently implemented national universal health care system. However, the national knowledge associate with the socio-technical aspects of health IT has not been studied in Thailand. A survey instrument measuring Thai health center (HC) personnel's computer use, basic IT knowledge and HC computerized information system functionality needs was developed. The instrument reveals acceptable test-retest reliability and reasonable internal consistency of the measures. The future nation-wide demonstration study will benefit from this study.

  19. User interface on networked workstations for MFTF plasma diagnostic instruments

    International Nuclear Information System (INIS)

    Renbarger, V.L.; Balch, T.R.

    1985-01-01

    A network of Sun-2/170 workstations is used to provide an interface to the MFTF-B Plasma Diagnostics System at Lawrence Livermore National Laboratory. The Plasma Diagnostics System (PDS) is responsible for control of MFTF-B plasma diagnostic instrumentation. An EtherNet Local Area Network links the workstations to a central multiprocessing system which furnishes data processing, data storage and control services for PDS. These workstations permit a physicist to command data acquisition, data processing, instrument control, and display of results. The interface is implemented as a metaphorical desktop, which helps the operator form a mental model of how the system works. As on a real desktop, functions are provided by sheets of paper (windows on a CRT screen) called worksheets. The worksheets may be invoked by pop-up menus and may be manipulated with a mouse. These worksheets are actually tasks that communicate with other tasks running in the central computer system. By making entries in the appropriate worksheet, a physicist may specify data acquisition or processing, control a diagnostic, or view a result

  20. The effects of display and autopilot functions on pilot workload for Single Pilot Instrument Flight Rule (SPIFR) operations

    Science.gov (United States)

    Hoh, Roger H.; Smith, James C.; Hinton, David A.

    1987-01-01

    An analytical and experimental research program was conducted to develop criteria for pilot interaction with advanced controls and displays in single pilot instrument flight rules (SPIFR) operations. The analytic phase reviewed fundamental considerations for pilot workload taking into account existing data, and using that data to develop a divided attention SPIFR pilot workload model. The pilot model was utilized to interpret the two experimental phases. The first experimental phase was a flight test program that evaluated pilot workload in the presence of current and near-term displays and autopilot functions. The second experiment was conducted on a King Air simulator, investigating the effects of co-pilot functions in the presence of very high SPIFR workload. The results indicate that the simplest displays tested were marginal for SPIFR operations. A moving map display aided the most in mental orientation, but had inherent deficiencies as a stand alone replacement for an HSI. Autopilot functions were highly effective for reducing pilot workload. The simulator tests showed that extremely high workload situations can be adequately handled when co-pilot functions are provided.

  1. Frequency-modulated impulse response photothermal detection through optical reflectance. 2: Experimental.

    Science.gov (United States)

    Power, J F; Mandelis, A

    1988-08-15

    A fast thermoreflectance impulse response photothermal imager was assembled and tested with several solid materials [quartz, stainless steel, and polyvinylidene difluoride (PVDF)I. The instrument was found to yield quantitative data in agreement with Green's function theoretical models of time domain heat conduction. The FM chirp laser intensity modulation technique used in these experiments gave wide bandwidth photothermal signals and was found to be only limited by the FFT instrumentation frequency response (100 kHz). Thermal diffusivities were calculated, while thermal lensing and thermoelastic effects were further observed. The imager was thus shown to be capable of replacing pulsed laser devices for truly nondestructive applications with materials with low damage threshold to optical pulses.

  2. Qualitative observation instrument to measure the quality of parent-child interactions in young children with type 1 diabetes mellitus.

    Science.gov (United States)

    Nieuwesteeg, Anke; Hartman, Esther; Pouwer, Frans; Emons, Wilco; Aanstoot, Henk-Jan; Van Mil, Edgar; Van Bakel, Hedwig

    2014-06-10

    In young children with type 1 diabetes mellitus (T1DM), parents have complete responsibility for the diabetes-management. In toddlers and (pre)schoolers, the tasks needed to achieve optimal blood glucose control may interfere with normal developmental processes and could negatively affect the quality of parent-child interaction. Several observational instruments are available to measure the quality of the parent-child interaction. However, no observational instrument for diabetes-specific situations is available. Therefore, the aim of the present study was to develop a qualitative observation instrument, to be able to assess parent-child interaction during diabetes-specific situations. First, in a pilot study (n = 15), the observation instrument was developed in four steps: (a) defining relevant diabetes-specific situations; (b) videotaping these situations; (c) describing all behaviors in a qualitative observation instrument; (d) evaluating usability and reliability. Next, we examined preliminary validity (total n = 77) by testing hypotheses about correlations between the observation instrument for diabetes-specific situations, a generic observation instrument and a behavioral questionnaire. The observation instrument to assess parent-child interaction during diabetes-specific situations, which consists of ten domains: "emotional involvement", "limit setting", "respect for autonomy", "quality of instruction", "negative behavior", "avoidance", "cooperative behavior", "child's response to injection", "emphasis on diabetes", and "mealtime structure", was developed for use during a mealtime situation (including glucose monitoring and insulin administration). The present study showed encouraging indications for the usability and inter-rater reliability (weighted kappa was 0.73) of the qualitative observation instrument. Furthermore, promising indications for the preliminary validity of the observation instrument for diabetes-specific situations were found (r ranged

  3. Comparison of dose response functions for EBT3 model GafChromic™ film dosimetry system.

    Science.gov (United States)

    Aldelaijan, Saad; Devic, Slobodan

    2018-05-01

    Different dose response functions of EBT3 model GafChromic™ film dosimetry system have been compared in terms of sensitivity as well as uncertainty vs. error analysis. We also made an assessment of the necessity of scanning film pieces before and after irradiation. Pieces of EBT3 film model were irradiated to different dose values in Solid Water (SW) phantom. Based on images scanned in both reflection and transmission mode before and after irradiation, twelve different response functions were calculated. For every response function, a reference radiochromic film dosimetry system was established by generating calibration curve and by performing the error vs. uncertainty analysis. Response functions using pixel values from the green channel demonstrated the highest sensitivity in both transmission and reflection mode. All functions were successfully fitted with rational functional form, and provided an overall one-sigma uncertainty of better than 2% for doses above 2 Gy. Use of pre-scanned images to calculate response functions resulted in negligible improvement in dose measurement accuracy. Although reflection scanning mode provides higher sensitivity and could lead to a more widespread use of radiochromic film dosimetry, it has fairly limited dose range and slightly increased uncertainty when compared to transmission scan based response functions. Double-scanning technique, either in transmission or reflection mode, shows negligible improvement in dose accuracy as well as a negligible increase in dose uncertainty. Normalized pixel value of the images scanned in transmission mode shows linear response in a dose range of up to 11 Gy. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  4. Instrumented cardiac microphysiological devices via multimaterial three-dimensional printing

    Science.gov (United States)

    Lind, Johan U.; Busbee, Travis A.; Valentine, Alexander D.; Pasqualini, Francesco S.; Yuan, Hongyan; Yadid, Moran; Park, Sung-Jin; Kotikian, Arda; Nesmith, Alexander P.; Campbell, Patrick H.; Vlassak, Joost J.; Lewis, Jennifer A.; Parker, Kevin K.

    2017-03-01

    Biomedical research has relied on animal studies and conventional cell cultures for decades. Recently, microphysiological systems (MPS), also known as organs-on-chips, that recapitulate the structure and function of native tissues in vitro, have emerged as a promising alternative. However, current MPS typically lack integrated sensors and their fabrication requires multi-step lithographic processes. Here, we introduce a facile route for fabricating a new class of instrumented cardiac microphysiological devices via multimaterial three-dimensional (3D) printing. Specifically, we designed six functional inks, based on piezo-resistive, high-conductance, and biocompatible soft materials that enable integration of soft strain gauge sensors within micro-architectures that guide the self-assembly of physio-mimetic laminar cardiac tissues. We validated that these embedded sensors provide non-invasive, electronic readouts of tissue contractile stresses inside cell incubator environments. We further applied these devices to study drug responses, as well as the contractile development of human stem cell-derived laminar cardiac tissues over four weeks.

  5. Functional Associations by Response Overlap (FARO, a functional genomics approach matching gene expression phenotypes.

    Directory of Open Access Journals (Sweden)

    Henrik Bjørn Nielsen

    2007-08-01

    Full Text Available The systematic comparison of transcriptional responses of organisms is a powerful tool in functional genomics. For example, mutants may be characterized by comparing their transcript profiles to those obtained in other experiments querying the effects on gene expression of many experimental factors including treatments, mutations and pathogen infections. Similarly, drugs may be discovered by the relationship between the transcript profiles effectuated or impacted by a candidate drug and by the target disease. The integration of such data enables systems biology to predict the interplay between experimental factors affecting a biological system. Unfortunately, direct comparisons of gene expression profiles obtained in independent, publicly available microarray experiments are typically compromised by substantial, experiment-specific biases. Here we suggest a novel yet conceptually simple approach for deriving 'Functional Association(s by Response Overlap' (FARO between microarray gene expression studies. The transcriptional response is defined by the set of differentially expressed genes independent from the magnitude or direction of the change. This approach overcomes the limited comparability between studies that is typical for methods that rely on correlation in gene expression. We apply FARO to a compendium of 242 diverse Arabidopsis microarray experimental factors, including phyto-hormones, stresses and pathogens, growth conditions/stages, tissue types and mutants. We also use FARO to confirm and further delineate the functions of Arabidopsis MAP kinase 4 in disease and stress responses. Furthermore, we find that a large, well-defined set of genes responds in opposing directions to different stress conditions and predict the effects of different stress combinations. This demonstrates the usefulness of our approach for exploiting public microarray data to derive biologically meaningful associations between experimental factors. Finally, our

  6. Assessment of exposure-response functions for rocket-emission toxicants

    National Research Council Canada - National Science Library

    Subcommittee on Rocket-Emission Toxicants, National Research Council

    ... aborted launch that results in a rocket being destroyed near the ground. Assessment of Exposure-Response Functions for Rocket-Emmission Toxicants evaluates the model and the data used for three rocket emission toxicants...

  7. Parental questionnaire as a screening instrument for motor function at age five.

    Science.gov (United States)

    Nordbye-Nielsen, Kirsten; Kesmodel, Ulrik Schiøler

    2014-12-01

    No standardised method is used to determine motor function in children in general practice in Denmark. Our aim was to evaluate the correlation between a parental questionnaire assessing motor function at the age of five years and the clinical test Movement Assessment Battery for Children (M-ABC), and to assess whether one or more questions could be used to screen for motor problems at the age of five years. This study was based on a parental questionnaire containing ten questions. The M-ABC was used as the gold standard. n = 755 children. The Mann-Whitney rank sum test, Pearson's χ(2)-test, logistic regression analyses and sensitivity and specificity were used to assess the correlation between the questionnaire and the M-ABC test. The best screening tool was six questions in combination: sensitivity 39.8%, specificity 87.1%. Asking if a health professional ever expressed concern about the childs motor development had a sensitivity of 17.0% and a specificity of 93.9%. A parental questionnaire used as a screening instrument to identify children with motor problems has a reasonable specificity, but a low sensitivity. The six questions can be used to identify children who do not have motor function difficulties with a relatively high certainty, and it can fairly well identify children with motor function problems. This study was primarily supported by the Centers for Disease Control and Prevention (CDC), Atlanta, Georgia, USA. Additional support was obtained from The Danish Health and Medicines Authority, the Lundbeck Foundation, Ludvig & Daara Elsass Foundation, the Augustinus Foundation, and Aase & Ejnar Danielsens Foundation. The Danish National Research Foundation has established the Danish Epidemiology Science Centre that initiated and created the Danish National Birth Cohort. The cohort is furthermore a result of a major grant from this Foundation. Additional support for the Danish National Birth Cohort is obtained from the Pharmacy Foundation, the Egmont

  8. Regulatory requirements and quality assurance of radiation monitoring instruments

    International Nuclear Information System (INIS)

    Narasimharao, K.L.; Sharma, Ranjit

    2005-01-01

    The successful utilisation of radiation sources in the fields of medicine and industry requires the accurate measurement of activity, exposure rate and dose. Many varieties of instruments are in use for measurement of these parameters and new ones are being developed. The criteria for the design of the radiation monitoring instrument include the type and intensity of the radiation, purpose of measurement and ruggedness of the instrument. Quality and reliability of radiation monitoring instruments ensure that individuals are adequately protected. Accuracy, response time and ruggedness are required to be as per the approved/ prescribed guidelines. Regulatory authorities outline the design and performance criteria for radiation monitoring instruments and prescribe the recommendations of international agencies such as IAEA, ICRU and ISO for radiological measurement assurance programme. National Standards Laboratories all over the world prescribe procedures for calibration of various radiation monitoring instruments. The instruments should be calibrated as per these guidelines and should be traceable to national standards. The calibration traceable to national/ international standards and documentation as well as limits stipulated by the competent authority ensures the expected performance of the instrument. (author)

  9. The transfer function model for dynamic response of wet cooling coils

    International Nuclear Information System (INIS)

    Yao Ye; Liu Shiqing

    2008-01-01

    This paper mainly concerned about the dynamic response model of wet cooling coils that is developed by the Laplace transform method. The theoretic equations are firstly established based on the theory of energy conservation. Then, the transfer functions on the transient responses of wet cooling coils have been deduced using the method of Laplace transform. The transfer functions reveal the dynamic relationships between the inlet variables and the outlet ones of the cooling coils. Partial-fraction method and Newton-Raphson method are both used in the inversion of the transfer functions from the s-domain to τ-domain. To make the dynamic model of wet cooling coils more adaptive, RBFNN method is employed to determine the coefficients of heat and mass transfer. Experiments have been done and manifested that the coefficients of heat and mass transfer by RBFNN will be of great value to the validity of the transient response model of wet cooling coils in this study

  10. Students' Perceptions of Emotional and Instrumental Teacher Support: Relations with Motivational and Emotional Responses

    Science.gov (United States)

    Federici, Roger A.; Skaalvik, Einar M.

    2014-01-01

    We explored whether students' perceptions of emotional and instrumental support provided by their mathematics teacher constitute separate dimensions of teacher support and how they are related. We also analyzed how students' perceptions of emotional and instrumental support in math lessons relate to math anxiety, intrinsic motivation, help-seeking…

  11. Visual tracking of da Vinci instruments for laparoscopic surgery

    Science.gov (United States)

    Speidel, S.; Kuhn, E.; Bodenstedt, S.; Röhl, S.; Kenngott, H.; Müller-Stich, B.; Dillmann, R.

    2014-03-01

    Intraoperative tracking of laparoscopic instruments is a prerequisite to realize further assistance functions. Since endoscopic images are always available, this sensor input can be used to localize the instruments without special devices or robot kinematics. In this paper, we present an image-based markerless 3D tracking of different da Vinci instruments in near real-time without an explicit model. The method is based on different visual cues to segment the instrument tip, calculates a tip point and uses a multiple object particle filter for tracking. The accuracy and robustness is evaluated with in vivo data.

  12. Industrial measurement instruments that use radioisotopes

    International Nuclear Information System (INIS)

    Monno, Asao

    2004-01-01

    An example of a large-scale system for controlling hot rolling, and recent developments for a gamma-ray thickness gauge for the inner-mill housing of a plate and a thickness gauge for a hot seamless tube mill are introduced. The dramatically higher speed response, versatile intelligent elements, larger data capacity and formation of a database are advantages of these instruments over conventional devices. Moreover, Fuji Electric's industrial measuring instruments that use radioisotopes are manufactured and marketed to be compatible with those of Hitachi, and we have already compiled a track record of many deliveries. (author)

  13. Functional Associations by Response Overlap (FARO), a functional genomics approach matching gene expression phenotypes

    DEFF Research Database (Denmark)

    Nielsen, Henrik Bjørn; Mundy, J.; Willenbrock, Hanni

    2007-01-01

    The systematic comparison of transcriptional responses of organisms is a powerful tool in functional genomics. For example, mutants may be characterized by comparing their transcript profiles to those obtained in other experiments querying the effects on gene expression of many experimental facto...

  14. Decreased prefrontal functional brain response during memory testing in women with Cushing's syndrome in remission.

    Science.gov (United States)

    Ragnarsson, Oskar; Stomby, Andreas; Dahlqvist, Per; Evang, Johan A; Ryberg, Mats; Olsson, Tommy; Bollerslev, Jens; Nyberg, Lars; Johannsson, Gudmundur

    2017-08-01

    Neurocognitive dysfunction is an important feature of Cushing's syndrome (CS). Our hypothesis was that patients with CS in remission have decreased functional brain responses in the prefrontal cortex and hippocampus during memory testing. In this cross-sectional study we included 19 women previously treated for CS and 19 controls matched for age, gender, and education. The median remission time was 7 (IQR 6-10) years. Brain activity was studied with functional magnetic resonance imaging during episodic- and working-memory tasks. The primary regions of interest were the prefrontal cortex and the hippocampus. A voxel-wise comparison of functional brain responses in patients and controls was performed. During episodic-memory encoding, patients displayed lower functional brain responses in the left and right prefrontal gyrus (pright inferior occipital gyrus (pbrain responses in the left posterior hippocampus in patients (p=0.05). During episodic-memory retrieval, the patients displayed lower functional brain responses in several brain areas with the most predominant difference in the right prefrontal cortex (pbrain response during a more complex working memory task compared with a simpler one. In conclusion, women with CS in long-term remission have reduced functional brain responses during episodic and working memory testing. This observation extends previous findings showing long-term adverse effects of severe hypercortisolaemia on brain function. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. The installation and operation of the seismic instrumentation in Korean NPPs

    International Nuclear Information System (INIS)

    Lee, Kye Hyun; Baek, Yong Lak; Chung, Yun Suk

    1994-01-01

    Including the 7 October, 1978, Hongsung earthquake, many earthquakes have occurred in our country. The Korean peninsular is no longer a safety zone against earthquakes, and there are possibilities of the damage they cause. So therefore, it is essential to verify the safety of the safety-related facilities in the event of an earthquake. If an earthquake occurs, seismic instrumentation provides information on the vibratory ground motion and resultant vibratory responses of representative safety-related structures and equipment so that an evaluation can be made immediately as to whether or not the design response spectra have been exceeded. In this paper, general descriptions of the seismic instrumentation installed in domestic NPPs will be discussed; this includes instrument type and location, the Operating Basis Earthquake (OBE) exceedance criteria, and processing and evaluation of earthquake response data, and items to be studied for further enhancement of post-earthquake evaluation techniques are presented

  16. Functional significance of the electrocorticographic auditory responses in the premotor cortex

    Directory of Open Access Journals (Sweden)

    Kazuyo eTanji

    2015-03-01

    Full Text Available Other than well-known motor activities in the precentral gyrus, functional magnetic resonance imaging (fMRI studies have found that the ventral part of the precentral gyrus is activated in response to linguistic auditory stimuli. It has been proposed that the premotor cortex in the precentral gyrus is responsible for the comprehension of speech, but the precise function of this area is still debated because patients with frontal lesions that include the precentral gyrus do not exhibit disturbances in speech comprehension. We report on a patient who underwent resection of the tumor in the precentral gyrus with electrocorticographic recordings while she performed the verb generation task during awake brain craniotomy. Consistent with previous fMRI studies, high-gamma band auditory activity was observed in the precentral gyrus. Due to the location of the tumor, the patient underwent resection of the auditory responsive precentral area which resulted in the post-operative expression of a characteristic articulatory disturbance known as apraxia of speech (AOS. The language function of the patient was otherwise preserved and she exhibited intact comprehension of both spoken and written language. The present findings demonstrated that a lesion restricted to the ventral precentral gyrus is sufficient for the expression of AOS and suggest that the auditory-responsive area plays an important role in the execution of fluent speech rather than the comprehension of speech. These findings also confirm that the function of the premotor area is predominantly motor in nature and its sensory responses is more consistent with the ‘sensory theory of speech production’, in which it was proposed that sensory representations are used to guide motor-articulatory processes.

  17. A Geometrical Method for Sound-Hole Size and Location Enhancement in Lute Family Musical Instruments: The Golden Method

    Directory of Open Access Journals (Sweden)

    Soheil Jafari

    2017-11-01

    Full Text Available This paper presents a new analytical approach, the Golden Method, to enhance sound-hole size and location in musical instruments of the lute family in order to obtain better sound damping characteristics based on the concept of the golden ratio and the instrument geometry. The main objective of the paper is to increase the capability of lute family musical instruments in keeping a note for a certain time at a certain level to enhance the instruments’ orchestral characteristics. For this purpose, a geometry-based analytical method, the Golden Method is first described in detail in an itemized feature. A new musical instrument is then developed and tested to confirm the ability of the Golden Method in optimizing the acoustical characteristics of musical instruments from a damping point of view by designing the modified sound-hole. Finally, the new-developed instrument is tested, and the obtained results are compared with those of two well-known instruments to confirm the effectiveness of the proposed method. The experimental results show that the suggested method is able to increase the sound damping time by at least 2.4% without affecting the frequency response function and other acoustic characteristics of the instrument. This methodology could be used as the first step in future studies on design, optimization and evaluation of musical instruments of the lute family (e.g., lute, oud, barbat, mandolin, setar, and etc..

  18. Identifying functional groups for response to disturbance in an abandoned pasture

    Science.gov (United States)

    Lavorel, Sandra; Touzard, Blaise; Lebreton, Jean-Dominique; Clément, Bernard

    1998-06-01

    In an abandoned pasture in Brittany, we compared artificial small-scale disturbances to natural disturbances by wild boar and undisturbed vegetation. We developed a multivariate statistical approach which analyses how species biological attributes explain the response of community composition to disturbances. This technique, which reconciles the inductive and deductive approaches for functional classifications, identifies groups of species with similar responses to disturbance and characterizes their biological profiles. After 5 months of recolonization, artificial disturbances had a greater species richness than undisturbed vegetation as a result of recruitment of new species without the exclusion of pre-existing matrix species. Species morphology, described by canopy structure, canopy height and lateral spread, explained a large part (16 %) of community response to disturbance. Regeneration strategies, described by life history, seed mass, dispersal agent, dormancy and the existence of vegetative multiplication, explained a smaller part of community response to disturbance (8 %). Artificial disturbances were characterized by therophyte and compact rosettes with moderately dormant seeds, including a number of Asteraceae and other early successional species. Natural disturbances were colonized by leafy guerrilla species without seed dormancy. Few species were tightly related to undisturbed vegetation and were essentially grasses with a phalanx rosette morphology. The functional classification obtained is consistent with the classification of the community into fugitives, regenerators and persistors. These groups are structured according to Grubb's model for temperate grasslands, with regenerators and persistors in the matrix and fugitives taking advantage of gaps open by small-scale disturbances. The conjunction of functional diversity and species diversity within functional groups is the key to resilience to disturbance, an important ecosystem function.

  19. Functional criteria for emergency response facilities. Technical report (final)

    International Nuclear Information System (INIS)

    1981-02-01

    This report describes the facilities and systems to be used by nuclear power plant licensees to improve responses to emergency situations. The facilities include the Technical Support Center (TSC), Onsite Operational Support Center (OSC), and Nearsite Emergency Operations Facility (EOF), as well as a brief discussion of the emergency response function of the control room. The data systems described are the Safety Parameter Display System (SPDS) and Nuclear Data Link (NDL). Together, these facilities and systems make up the total Emergency Response Facilities (ERFs). Licensees should follow the guidance provided both in this report and in NUREG-0654 (FEMA-REP-1), Revision 1, for design and implementation of the ERFs

  20. Instrument adaptation and validation to evaluate psychosocial skills and healthy habits in schoolchildren

    Directory of Open Access Journals (Sweden)

    Lucila Niño-Bautista

    2017-12-01

    Full Text Available Objective: To adapt and validate an evaluation tool on psychosocial skills for life and healthy habits in Schoolchildren from a locality in Bogota, Colombia. Materials and methods: This quantitative transversal with empirical analytical non-experimental approach study evaluated responses of schoolchildren in third and fourth grade of primary school with the instrument adapted and reconstructed to establish technical quality of items, reliability and validity of it. The instrument (18 psychosocial skills and 19 healthy habits, plus 4 identification items was self-diligence with Yes, No dichotomous answer option. It had evidence of apparent validity with schoolchildren from other peer institutions and was tested at 32 Public schools and analyzed using the Rasch model. Results: 1,066 schoolchildren participated in total. The items of the two constructs showed a good fit to the Rasch model as well as unidimensionality, reliability and separation measures above the recommended values. There was no differential functioning of the item by sex. Conclusion: The instrument of 37 items presented good properties of validity, reliability and adjustment to Rasch; although it does not have enough items of high difficulty level, which can be corrected in future applications.

  1. Spectral envelope sensitivity of musical instrument sounds.

    Science.gov (United States)

    Gunawan, David; Sen, D

    2008-01-01

    It is well known that the spectral envelope is a perceptually salient attribute in musical instrument timbre perception. While a number of studies have explored discrimination thresholds for changes to the spectral envelope, the question of how sensitivity varies as a function of center frequency and bandwidth for musical instruments has yet to be addressed. In this paper a two-alternative forced-choice experiment was conducted to observe perceptual sensitivity to modifications made on trumpet, clarinet and viola sounds. The experiment involved attenuating 14 frequency bands for each instrument in order to determine discrimination thresholds as a function of center frequency and bandwidth. The results indicate that perceptual sensitivity is governed by the first few harmonics and sensitivity does not improve when extending the bandwidth any higher. However, sensitivity was found to decrease if changes were made only to the higher frequencies and continued to decrease as the distorted bandwidth was widened. The results are analyzed and discussed with respect to two other spectral envelope discrimination studies in the literature as well as what is predicted from a psychoacoustic model.

  2. How To Control Color Appearance With Instrumentation

    Science.gov (United States)

    Burns, Margaret E.

    1980-05-01

    Colorimetry, as defined by the International Commission on Illumination, is the measurement of colors, made possible by the properties of the eye and based on a set of conventions. Instrumentation for measuring object color, therefore, must be based on a human observer. The intent is to design an instrument that in effect responds as a person would, so that research development, production control and quality control areas have some means of assessing the acceptability of the appearance of a product. Investigations of a human observer's psychological response to color, and the manner in which visual observations are made, give the instrument designer and manufacturer data necessary to answer two questions: a. How can we put numbers (instrument read-out) on a perception that occurs in the brain of the observer? b. What can we learn from examination of a visual observing situation that will guide us in our design of an instrumental simulation of this situation? Involving as it does our own daily, almost unconscious, practice of making judgments concerning the things we see, the design and manufacture of color measurement instruments is an exceedingly interesting field. The advances being made concurrently today in research concerning human color vision and in optical and electronic technology will make possible increasingly useful instrumentation for quality control of product color.

  3. Forest ecotone response to climate change: sensitivity to temperature response functional forms

    Energy Technology Data Exchange (ETDEWEB)

    Loehle, C. [National Council for Air and Stream Improvement, Naperville, IL (United States)

    2000-10-01

    Past simulation studies have been in general agreement that climatic change could have adverse effects on forests, including geographic range shrinkages, conversion to grassland, and catastrophic forest decline or dieback. Some other recent studies, however, concluded that this agreement is generally based on parabolic temperature response rather than functional responses or data, and may therefore exaggerate dieback effects. This paper proposes a new model of temperature response that is based on a trade-off between cold tolerance and growth rate. In this model, the growth rate increases at first, and then levels off with increasing growing degree-days. Species from more southern regions have a higher minimum temperature and a faster maximum height growth rate. It is argued that faster growth rates of southern types lead to their competitive superiority in warmer environments and that such temperature response should produce less dieback and slower rates of change than the more common parabolic response model. Theoretical justification of this model is provided, followed by application of the model to a simulated ecotone under a warming scenario. Results of the study based on the proposed asymptotic model showed no dieback and only a gradual ecotone movement north, suggesting that ecotone shifts will, in fact, take many hundreds to thousands of years, with the result that species will not face the risk of extinction. 56 refs., 1 tab., 8 figs.

  4. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  5. The spin polarized linear response from density functional theory: Theory and application to atoms

    Energy Technology Data Exchange (ETDEWEB)

    Fias, Stijn, E-mail: sfias@vub.ac.be; Boisdenghien, Zino; De Proft, Frank; Geerlings, Paul [General Chemistry (ALGC), Vrije Universiteit Brussel (Free University Brussels – VUB), Pleinlaan 2, 1050 Brussels (Belgium)

    2014-11-14

    Within the context of spin polarized conceptual density functional theory, the spin polarized linear response functions are introduced both in the [N, N{sub s}] and [N{sub α}, N{sub β}] representations. The mathematical relations between the spin polarized linear response functions in both representations are examined and an analytical expression for the spin polarized linear response functions in the [N{sub α}, N{sub β}] representation is derived. The spin polarized linear response functions were calculated for all atoms up to and including argon. To simplify the plotting of our results, we integrated χ(r, r′) to a quantity χ(r, r{sup ′}), circumventing the θ and ϕ dependence. This allows us to plot and to investigate the periodicity throughout the first three rows in the periodic table within the two different representations. For the first time, χ{sub αβ}(r, r{sup ′}), χ{sub βα}(r, r{sup ′}), and χ{sub SS}(r, r{sup ′}) plots have been calculated and discussed. By integration of the spin polarized linear response functions, different components to the polarisability, α{sub αα}, α{sub αβ}, α{sub βα}, and α{sub ββ} have been calculated.

  6. A Novel Low-Cost Instrumentation System for Measuring the Water Content and Apparent Electrical Conductivity of Soils

    Directory of Open Access Journals (Sweden)

    Alan Kardek Rêgo Segundo

    2015-10-01

    Full Text Available The scarcity of drinking water affects various regions of the planet. Although climate change is responsible for the water availability, humanity plays an important role in preserving this precious natural resource. In case of negligence, the likely trend is to increase the demand and the depletion of water resources due to the increasing world population. This paper addresses the development, design and construction of a low cost system for measuring soil volumetric water content (θ, electrical conductivity (σ and temperature (T, in order to optimize the use of water, energy and fertilizer in food production. Different from the existing measurement instruments commonly deployed in these applications, the proposed system uses an auto-balancing bridge circuit as measurement method. The proposed models to estimate θ and σ and correct them in function of T are compared to the ones reported in literature. The final prototype corresponds to a simple circuit connected to a pair of electrode probes, and presents high accuracy, high signal to noise ratio, fast response, and immunity to stray capacitance. The instrument calibration is based on salt solutions with known dielectric constant and electrical conductivity as reference. Experiments measuring clay and sandy soils demonstrate the satisfactory performance of the instrument.

  7. A Novel Low-Cost Instrumentation System for Measuring the Water Content and Apparent Electrical Conductivity of Soils.

    Science.gov (United States)

    Rêgo Segundo, Alan Kardek; Martins, José Helvecio; Monteiro, Paulo Marcos de Barros; de Oliveira, Rubens Alves; Freitas, Gustavo Medeiros

    2015-10-05

    The scarcity of drinking water affects various regions of the planet. Although climate change is responsible for the water availability, humanity plays an important role in preserving this precious natural resource. In case of negligence, the likely trend is to increase the demand and the depletion of water resources due to the increasing world population. This paper addresses the development, design and construction of a low cost system for measuring soil volumetric water content (θ), electrical conductivity (σ) and temperature (T), in order to optimize the use of water, energy and fertilizer in food production. Different from the existing measurement instruments commonly deployed in these applications, the proposed system uses an auto-balancing bridge circuit as measurement method. The proposed models to estimate θ and σ and correct them in function of T are compared to the ones reported in literature. The final prototype corresponds to a simple circuit connected to a pair of electrode probes, and presents high accuracy, high signal to noise ratio, fast response, and immunity to stray capacitance. The instrument calibration is based on salt solutions with known dielectric constant and electrical conductivity as reference. Experiments measuring clay and sandy soils demonstrate the satisfactory performance of the instrument.

  8. Response function of a moving contact line

    Science.gov (United States)

    Perrin, H.; Belardinelli, D.; Sbragaglia, M.; Andreotti, B.

    2018-04-01

    The hydrodynamics of a liquid-vapor interface in contact with a heterogeneous surface is largely impacted by the presence of defects at the smaller scales. Such defects introduce morphological disturbances on the contact line and ultimately determine the force exerted on the wedge of liquid in contact with the surface. From the mathematical point of view, defects introduce perturbation modes, whose space-time evolution is governed by the interfacial hydrodynamic equations of the contact line. In this paper we derive the response function of the contact line to such generic perturbations. The contact line response may be used to design simplified one-dimensional time-dependent models accounting for the complexity of interfacial flows coupled to nanoscale defects, yet offering a more tractable mathematical framework to explore contact line motion through a disordered energy landscape.

  9. Survey of beam instrumentation used in SLC

    International Nuclear Information System (INIS)

    Ecklund, S.D.

    1991-03-01

    A survey of beam instruments used at SLAC in the SLC machine is presented. The basic utility and operation of each device is briefly described. The various beam instruments used at the Stanford Linear Collider (SLC), can be classified by the function they perform. Beam intensity, position and size are typical of the parameters of beam which are measured. Each type of parameter is important for adjusting or tuning the machine in order to achieve optimum performance. 39 refs

  10. Improved instrumentation for intensity-, wavelength-, temperature-, and magnetic field-resolved photoconductivity spectroscopy

    International Nuclear Information System (INIS)

    Cottingham, Patrick; Morey, Jennifer R.; Lemire, Amanda; Lemire, Penny; McQueen, Tyrel M.

    2016-01-01

    We report instrumentation for photovoltage and photocurrent spectroscopy over a larger continuous range of wavelengths, temperatures, and applied magnetic fields than other instruments described in the literature: 350 nm≤λ≤1700 nm, 1.8 K≤T≤300 K, and B≤9 T. This instrument uses a modulated monochromated incoherent light source with total power<30 μW in combination with an LED in order to probe selected regions of non-linear responses while maintaining low temperatures and avoiding thermal artifacts. The instrument may also be used to measure a related property, the photomagnetoresistance. We demonstrate the importance of normalizing measured responses for variations in light power and describe a rigorous process for performing these normalizations. We discuss several circuits suited to measuring different types of samples and provide analysis for converting measured values into physically relevant properties. Uniform approaches to measurement of these photoproperties are essential for reliable quantitative comparisons between emerging new materials with energy applications. - Highlights: • A novel instrument for measuring photoconductivity and photocurrents of materials and devices. • Continuous parameter space: 350 nm≤λ≤1700, 1.8 K≤T≤300 K, and B≤9 T. • Methodology for treating non-linear responses and variable lamp intensity. • Mathematical detail for extracting properties of materials from measured values is provided.

  11. Systematic Review of Measurement Property Evidence for 8 Financial Management Instruments in Populations With Acquired Cognitive Impairment.

    Science.gov (United States)

    Engel, Lisa; Chui, Adora; Beaton, Dorcas E; Green, Robin E; Dawson, Deirdre R

    2018-03-07

    To critically appraise the measurement property evidence (ie, psychometric) for 8 observation-based financial management assessment instruments. Seven databases were searched in May 2015. Two reviewers used an independent decision-agreement process to select studies of measurement property evidence relevant to populations with adulthood acquired cognitive impairment, appraise the quality of the evidence, and extract data. Twenty-one articles were selected. This review used the COnsensus-based Standards for the selection of health Measurement Instruments review guidelines and 4-point tool to appraise evidence. After appraising the methodologic quality, the adequacy of results and volume of evidence per instrument were synthesized. Measurement property evidence with high risk of bias was excluded from the synthesis. The volume of measurement property evidence per instrument is low; most instruments had 1 to 3 included studies. Many included studies had poor methodologic quality per measurement property evidence area examined. Six of the 8 instruments reviewed had supporting construct validity/hypothesis-testing evidence of fair methodologic quality. There is a dearth of acceptable quality content validity, reliability, and responsiveness evidence for all 8 instruments. Rehabilitation practitioners assess financial management functions in adults with acquired cognitive impairments. However, there is limited published evidence to support using any of the reviewed instruments. Practitioners should exercise caution when interpreting the results of these instruments. This review highlights the importance of appraising the quality of measurement property evidence before examining the adequacy of the results and synthesizing the evidence. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  12. Thermo-responsive cell culture carrier: Effects on macrophage functionality and detachment efficiency.

    Science.gov (United States)

    Rennert, Knut; Nitschke, Mirko; Wallert, Maria; Keune, Natalie; Raasch, Martin; Lorkowski, Stefan; Mosig, Alexander S

    2017-01-01

    Harvesting cultivated macrophages for tissue engineering purposes by enzymatic digestion of cell adhesion molecules can potentially result in unintended activation, altered function, or behavior of these cells. Thermo-responsive polymer is a promising tool that allows for gentle macrophage detachment without artificial activation prior to subculture within engineered tissue constructs. We therefore characterized different species of thermo-responsive polymers for their suitability as cell substrate and to mediate gentle macrophage detachment by temperature shift. Primary human monocyte- and THP-1-derived macrophages were cultured on thermo-responsive polymers and characterized for phagocytosis and cytokine secretion in response to lipopolysaccharide stimulation. We found that both cell types differentially respond in dependence of culture and stimulation on thermo-responsive polymers. In contrast to THP-1 macrophages, primary monocyte-derived macrophages showed no signs of impaired viability, artificial activation, or altered functionality due to culture on thermo-responsive polymers compared to conventional cell culture. Our study demonstrates that along with commercially available UpCell carriers, two other thermo-responsive polymers based on poly(vinyl methyl ether) blends are attractive candidates for differentiation and gentle detachment of primary monocyte-derived macrophages. In summary, we observed similar functionality and viability of primary monocyte-derived macrophages cultured on thermo-responsive polymers compared to standard cell culture surfaces. While this first generation of custom-made thermo-responsive polymers does not yet outperform standard culture approaches, our results are very promising and provide the basis for exploiting the unique advantages offered by custom-made thermo-responsive polymers to further improve macrophage culture and recovery in the future, including the covalent binding of signaling molecules and the reduction of

  13. Technical testing of portable isotope identification instruments

    International Nuclear Information System (INIS)

    Smith, D.E.

    2001-01-01

    . First generation portable isotope identifiers were identified and evaluated by U.S. Customs. Instruments from five vendors were put through a battery of tests according to delineated test procedures. The tests fell into five categories: Basic operation verification; Medical isotope identification; Individual isotope identification; Isotope pair identification; Dose rate calculation. The tests can be summarized as an initial verification of correct instrument operation (including whatever calibration procedure was specified by the vendor), followed by three different isotope identification tests designed to verify the instrument's ability to correctly identify 19 isotopes specified by U.S. Customs. The final test determined each instrument's ability to correctly display the dose rate from a wide energy range of gamma emitters. The individual isotope identification test and the isotope pair identification test were performed with three types of intervening shielding. The first of these three types used the minimum packaging needed for safe source handling and was, in general, thin plastic. This type of shielding is virtually identical to a bare radiation source. The second type of shielding used 2.7 mm of steel to simulate the wall of a typical transportainer (or sea-tainer). The third type of shielding used 6.94 mm of lead to simulate typical industrial packaging or, perhaps, an attempt by the shipper to conceal the source without unduly increasing the weight of the shipment. The isotopes tested were broadly categorized as: Special nuclear material (SNM), Medical, and Industrial. These included 17 gamma emitters, 1 beta emitter, and 1 neutron emitter. Each instrument was subjected to the following testing regimen: First, each instrument was calibrated according to vendor's procedures. Instrument size and weight were recorded. Next, the instrument's response to medical isotopes in their usual shipping containers was measured. This represents the most commonly occurring

  14. A comprehensive review of sensors and instrumentation methods in devices for musical expression.

    Science.gov (United States)

    Medeiros, Carolina Brum; Wanderley, Marcelo M

    2014-07-25

    Digital Musical Instruments (DMIs) are musical instruments typically composed of a control surface where user interaction is measured by sensors whose values are mapped to sound synthesis algorithms. These instruments have gained interest among skilled musicians and performers in the last decades leading to artistic practices including musical performance, interactive installations and dance. The creation of DMIs typically involves several areas, among them: arts, design and engineering. The balance between these areas is an essential task in DMI design so that the resulting instruments are aesthetically appealing, robust, and allow responsive, accurate and repeatable sensing. In this paper, we review the use of sensors in the DMI community as manifested in the proceedings of the International Conference on New Interfaces for Musical Expression (NIME 2009-2013). Focusing on the sensor technologies and signal conditioning techniques used by the NIME community. Although it has been claimed that specifications for artistic tools are harder than those for military applications, this study raises a paradox showing that in most of the cases, DMIs are based on a few basic sensors types and unsophisticated engineering solutions, not taking advantage of more advanced sensing, instrumentation and signal processing techniques that could dramatically improve their response. We aim to raise awareness of limitations of any engineering solution and to assert the benefits of advanced electronics instrumentation design in DMIs. For this, we propose the use of specialized sensors such as strain gages, advanced conditioning circuits and signal processing tools such as sensor fusion. We believe that careful electronic instrumentation design may lead to more responsive instruments.

  15. The Los Alamos accelerator control system data base: A generic instrumentation interface

    International Nuclear Information System (INIS)

    Dalesio, L.R.

    1990-01-01

    Controlling experimental-physics applications requires a control system that can be quickly integrated and easily modified. One aspect of the control system is the interface to the instrumentation. An instrumentation set has been chosen to implement the basic functions needed to monitor and control these applications. A data-driven interface to this instrumentation set provides the required quick integration of the control system. This type of interface is limited by its built-in capabilities. Therefore, these capabilities must provide an adequate range of functions to be of any use. The data-driven interface must support the instrumentation range requird, the events on which to read or control the instrumentation and a method for manipulating the data to calculate terms or close control loops. The database for the Los Alamos Accelerator Control System addresses these requirements. (orig.)

  16. Novel seismic instrumentation for nuclear power plants

    International Nuclear Information System (INIS)

    Bolleter, W.; Savary, C.

    1998-01-01

    Conforming to the latest issues of the Nuclear Regulatory Commission Regulatory Guide, a novel hardware and software solution for seismic instrumentation is presented. Both instrumentation and PC-based data evaluation software for post-earthquake actions are type-tested and approved by the German TUeV. Reference installations replacing obsolete analog instrumentation were successfully completed and are presented. The instrumentation consists of highly linear, solid-state capacitive accelerometers as well as digital recorders storing the signals from the sensors in situ. These recorders are linked in a star-topology network to a central unit that permanently communicates with them via fiber-optic cable or current-loop links. The central unit is responsible for alerting and synchronizes all recorders which otherwise act autonomously. Data evaluation is handled by a PC-based software package. It includes automatic data evaluation after earthquakes (batch mode), interactive data evaluation software for detailed data analysis, and software tools for remote operation, maintenance and data storage. (author)

  17. Remote and Virtual Instrumentation Platform for Distance Learning

    Directory of Open Access Journals (Sweden)

    Tom Eppes

    2010-08-01

    Full Text Available This journal presents distance learning using the National Instruments ELVIS II and how Multisim can be combined with ELVIS II for distance learning. National Instrument’s ELVIS II is a new version that can easily be used for e-learning. It features 12 of the commonly used instruments in engineering and science laboratories, including an oscilloscope, a function generator, a variable power supply, and an isolated digital multi-meter in a low-cost and easy-to-use platform and completes integration with Multisim software for SPICE simulation, which simplifies the teaching of circuit design. As NI ELVIS II is based on LabView, designers can easily customize the 12 instruments or can create their own using the provided source code for the instruments.

  18. Robotic thin layer chromatography instrument for synthetic chemistry

    International Nuclear Information System (INIS)

    Corkan, L.A.; Haynes, E.; Kline, S.; Lindsey, J.S.

    1991-01-01

    We have constructed a second generation instrument for performing automated thin layer chromatography (TLC), The TLC instrument Consists of four dedicated stations for (1) plate dispensing, (2) sample application, (3) plate development, and (4) densitometry. A robot is used to move TLC plates among stations. The TLC instrument functions either as a stand-alone unit or as one analytical module in a robotic workstation for synthetic chemistry. An integrated hardware and software architecture enables automatic TLC analysis of samples produced concurrently from synthetic reactions in progress on the workstation. The combination of fixed automation and robotics gives a throughput of 12 TLC samples per hour. From these results a blueprint has emerged for an advanced automated TLC instrument with far greater throughput and analytical capabilities

  19. Extinction of Chained Instrumental Behaviors: Effects of Procurement Extinction on Consumption Responding

    Science.gov (United States)

    Thrailkill, Eric A.; Bouton, Mark E.

    2015-01-01

    Instrumental behavior often consists of sequences or chains of responses that minimally include procurement behaviors that enable subsequent consumption behaviors. In such chains, behavioral units are linked by access to one another and eventually to a primary reinforcer, such as food or a drug. The present experiments examined the effects of extinguishing procurement responding on consumption responding after training of a discriminated heterogeneous instrumental chain. Rats learned to make a procurement response (e.g., pressing a lever) in the presence of a distinctive discriminative stimulus; making that response led to the presentation of a second discriminative stimulus that set the occasion for a consumption response (e.g., pulling a chain), which then produced a food-pellet reinforcer. Experiment 1 showed that extinction of either the full procurement-consumption chain or procurement alone weakened the consumption response tested in isolation. Experiment 2 replicated the procurement extinction effect and further demonstrated that the opportunity to make the procurement response, as opposed to simple exposure to the procurement stimulus alone, was required. In Experiment 3, rats learned 2 distinct discriminated heterogeneous chains; extinction of 1 procurement response specifically weakened the consumption response that had been associated with it. The results suggest that learning to inhibit the procurement response may produce extinction of consumption responding through mediated extinction. The experiments suggest the importance of an associative analysis of instrumental behavior chains. PMID:25915751

  20. A new approach to evaluate the response functions for conical and cylindrical collimators

    International Nuclear Information System (INIS)

    Gigante, G.E.

    1989-01-01

    A new approach to the evaluation of the conical collimator response function is shown. The basic collimator formulae are reviewed. The collimator response function has been found in a very easy way. An approximate solution has been introduced. Studying the response of a measuring system, the use of this approximation strongly reduces the complexity of the relations to be used; therefore it would provide a useful starting point for a Monte Carlo calculation. The errors introduced are less than 10%. Approximate relations that allow the evaluation of the response of conical and cylindrical collimators to plane and line sources are also given. (orig.)

  1. [Construct validity of a Portuguese version of the Female Sexual Function Index].

    Science.gov (United States)

    Pacagnella, Rodolfo de Carvalho; Martinez, Edson Zangiacomi; Vieira, Elisabeth Meloni

    2009-11-01

    This study aimed to evaluate the construct validity of a version of the Female Sexual Function Index (FSFI). The version was inserted into a multidimensional questionnaire and applied face-to-face to 235 sterilized women. Non-response rate was 1.7%. The sample proved to be highly homogeneous, with low income and education. Cronbach's alpha of 0.948 indicated high internal consistency. Factor analysis showed that the instrument was measuring four factors: desire/arousal, lubrication, orgasm/satisfaction, and pain. This may reflect characteristics of the instrument itself, female sexual response, or even the sample's cultural peculiarities, which can affect understanding of the questions or concepts with which the instrument deals. This study emphasizes the need for further research in the general population to determine the psychometric properties of the FSFI, such as its factor composition and definition of appropriate cut-off points for the Brazilian population.

  2. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  3. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  4. Single-chip microcomputer application in nuclear radiation monitoring instruments

    International Nuclear Information System (INIS)

    Zhang Songshou

    1994-01-01

    The single-chip microcomputer has advantage in many respects i.e. multiple function, small size, low-power consumption,reliability etc. It is widely used now in industry, instrumentation, communication and machinery. The author introduced usage of single-chip microcomputer in nuclear radiation monitoring instruments for control, linear compensation, calculation, changeable parameter presetting and military training

  5. Measuring the Quality of Life of Visually Impaired Children: First Stage Psychometric Evaluation of the Novel VQoL_CYP Instrument.

    Directory of Open Access Journals (Sweden)

    Valerija Tadić

    Full Text Available To report piloting and initial validation of the VQoL_CYP, a novel age-appropriate vision-related quality of life (VQoL instrument for self-reporting by children with visual impairment (VI.Participants were a random patient sample of children with VI aged 10-15 years. 69 patients, drawn from patient databases at Great Ormond Street Hospital and Moorfields Eye Hospital, United Kingdom, participated in piloting of the draft 47-item VQoL instrument, which enabled preliminary item reduction. Subsequent administration of the instrument, alongside functional vision (FV and generic health-related quality of life (HRQoL self-report measures, to 101 children with VI comprising a nationally representative sample enabled further item reduction and evaluation of psychometric properties using Rasch analysis. Construct validity was assessed through Pearson correlation coefficients.Item reduction through piloting (8 items removed for skewness and individual item response pattern and validation (1 item removed for skewness and 3 for misfit in Rasch produced a 35-item scale, with fit values within acceptable limits, no notable differential item functioning, good measurement precision, ordered response categories and acceptable targeting in Rasch. The VQoL_CYP showed good construct validity, correlating strongly with HRQoL scores, moderately with FV scores but not with acuity.Robust child-appropriate self-report VQoL measures for children with VI are necessary for understanding the broader impacts of living with a visual disability, distinguishing these from limited functioning per se. Future planned use in larger patient samples will allow further psychometric development of the VQoL_CYP as an adjunct to objective outcomes assessment.

  6. A review of instruments to measure interprofessional team-based primary care.

    Science.gov (United States)

    Shoemaker, Sarah J; Parchman, Michael L; Fuda, Kathleen Kerwin; Schaefer, Judith; Levin, Jessica; Hunt, Meaghan; Ricciardi, Richard

    2016-07-01

    Interprofessional team-based care is increasingly regarded as an important feature of delivery systems redesigned to provide more efficient and higher quality care, including primary care. Measurement of the functioning of such teams might enable improvement of team effectiveness and could facilitate research on team-based primary care. Our aims were to develop a conceptual framework of high-functioning primary care teams to identify and review instruments that measure the constructs identified in the framework, and to create a searchable, web-based atlas of such instruments (available at: http://primarycaremeasures.ahrq.gov/team-based-care/ ). Our conceptual framework was developed from existing frameworks, the teamwork literature, and expert input. The framework is based on an Input-Mediator-Output model and includes 12 constructs to which we mapped both instruments as a whole, and individual instrument items. Instruments were also reviewed for relevance to measuring team-based care, and characterized. Instruments were identified from peer-reviewed and grey literature, measure databases, and expert input. From nearly 200 instruments initially identified, we found 48 to be relevant to measuring team-based primary care. The majority of instruments were surveys (n = 44), and the remainder (n = 4) were observational checklists. Most instruments had been developed/tested in healthcare settings (n = 30) and addressed multiple constructs, most commonly communication (n = 42), heedful interrelating (n = 42), respectful interactions (n = 40), and shared explicit goals (n = 37). The majority of instruments had some reliability testing (n = 39) and over half included validity testing (n = 29). Currently available instruments offer promise to researchers and practitioners to assess teams' performance, but additional work is needed to adapt these instruments for primary care settings.

  7. Linearization of Positional Response Curve of a Fiber-optic Displacement Sensor

    Science.gov (United States)

    Babaev, O. G.; Matyunin, S. A.; Paranin, V. D.

    2018-01-01

    Currently, the creation of optical measuring instruments and sensors for measuring linear displacement is one of the most relevant problems in the area of instrumentation. Fiber-optic contactless sensors based on the magneto-optical effect are of special interest. They are essentially contactless, non-electrical and have a closed optical channel not subject to contamination. The main problem of this type of sensors is the non-linearity of their positional response curve due to the hyperbolic nature of the magnetic field intensity variation induced by moving the magnetic source mounted on the controlled object relative to the sensing element. This paper discusses an algorithmic method of linearizing the positional response curve of fiber-optic displacement sensors in any selected range of the displacements to be measured. The method is divided into two stages: 1 - definition of the calibration function, 2 - measurement and linearization of the positional response curve (including its temperature stabilization). The algorithm under consideration significantly reduces the number of points of the calibration function, which is essential for the calibration of temperature dependence, due to the use of the points that randomly deviate from the grid points with uniform spacing. Subsequent interpolation of the deviating points and piecewise linear-plane approximation of the calibration function reduces the microcontroller storage capacity for storing the calibration function and the time required to process the measurement results. The paper also presents experimental results of testing real samples of fiber-optic displacement sensors.

  8. A postprocessing method in the HMC framework for predicting gene function based on biological instrumental data

    Science.gov (United States)

    Feng, Shou; Fu, Ping; Zheng, Wenbin

    2018-03-01

    Predicting gene function based on biological instrumental data is a complicated and challenging hierarchical multi-label classification (HMC) problem. When using local approach methods to solve this problem, a preliminary results processing method is usually needed. This paper proposed a novel preliminary results processing method called the nodes interaction method. The nodes interaction method revises the preliminary results and guarantees that the predictions are consistent with the hierarchy constraint. This method exploits the label dependency and considers the hierarchical interaction between nodes when making decisions based on the Bayesian network in its first phase. In the second phase, this method further adjusts the results according to the hierarchy constraint. Implementing the nodes interaction method in the HMC framework also enhances the HMC performance for solving the gene function prediction problem based on the Gene Ontology (GO), the hierarchy of which is a directed acyclic graph that is more difficult to tackle. The experimental results validate the promising performance of the proposed method compared to state-of-the-art methods on eight benchmark yeast data sets annotated by the GO.

  9. Using item response theory to address vulnerabilities in FFQ.

    Science.gov (United States)

    Kazman, Josh B; Scott, Jonathan M; Deuster, Patricia A

    2017-09-01

    The limitations for self-reporting of dietary patterns are widely recognised as a major vulnerability of FFQ and the dietary screeners/scales derived from FFQ. Such instruments can yield inconsistent results to produce questionable interpretations. The present article discusses the value of psychometric approaches and standards in addressing these drawbacks for instruments used to estimate dietary habits and nutrient intake. We argue that a FFQ or screener that treats diet as a 'latent construct' can be optimised for both internal consistency and the value of the research results. Latent constructs, a foundation for item response theory (IRT)-based scales (e.g. Patient Reported Outcomes Measurement Information System) are typically introduced in the design stage of an instrument to elicit critical factors that cannot be observed or measured directly. We propose an iterative approach that uses such modelling to refine FFQ and similar instruments. To that end, we illustrate the benefits of psychometric modelling by using items and data from a sample of 12 370 Soldiers who completed the 2012 US Army Global Assessment Tool (GAT). We used factor analysis to build the scale incorporating five out of eleven survey items. An IRT-driven assessment of response category properties indicates likely problems in the ordering or wording of several response categories. Group comparisons, examined with differential item functioning (DIF), provided evidence of scale validity across each Army sub-population (sex, service component and officer status). Such an approach holds promise for future FFQ.

  10. A 'hybrid' neutron area survey instrument for the determination of neutron dose quantities in the workplace

    International Nuclear Information System (INIS)

    Tanner, R.J.; Jenkins, R.; Lowe, T.; Silvie, J.; Joyce, M.J.; Winsby, A.; Molinos, C.

    2005-01-01

    Full text: Neutron survey instruments are used routinely to determine the dose rates in areas where persons may be occupationally exposed. With a few exceptions, these instruments generally use a proportional counter with a high thermal neutron response located in a moderating sphere of CH 2 . The moderating sphere in such designs contains a thermal neutron absorber to reduce the over-response to thermal and intermediate energy neutrons. However, the commercially available examples of such instruments tend to have strongly energy dependent ambient dose equivalent response characteristics. In particular, they often over-respond in the energy range between 1 eV and 10 keV. A prototype of a novel design has been produced that uses seven detectors located in a moderating sphere of CH 2 , six near the surface to detect thermal and epithermal neutrons, and one in the centre to detect fast neutrons. This has been characterized using a combination of MCNP modelling and measurements to produce an instrument that has improved energy dependence of response characteristics. Additionally, the use of seven detectors offers direction and field hardness information. The design and calibration of the instrument are described and its response in workplaces calculated. (author)

  11. Spontaneous symmetry breaking and response functions

    International Nuclear Information System (INIS)

    Beraudo, A.; De Pace, A.; Martini, M.; Molinari, A.

    2005-01-01

    We study the quantum phase transition occurring in an infinite homogeneous system of spin 1/2 fermions in a non-relativistic context. As an example we consider neutrons interacting through a simple spin-spin Heisenberg force. The two critical values of the coupling strength-signaling the onset into the system of a finite magnetization and of the total magnetization, respectively-are found and their dependence upon the range of the interaction is explored. The spin response function of the system in the region where the spin-rotational symmetry is spontaneously broken is also studied. For a ferromagnetic interaction the spin response along the direction of the spontaneous magnetization occurs in the particle-hole continuum and displays, for not too large momentum transfers, two distinct peaks. The response along the direction orthogonal to the spontaneous magnetization displays instead, beyond a softened and depleted particle-hole continuum, a collective mode to be identified with a Goldstone boson of type II. Notably, the random phase approximation on a Hartree-Fock basis accounts for it, in particular for its quadratic-close to the origin-dispersion relation. It is shown that the Goldstone boson contributes to the saturation of the energy-weighted sum rule for ∼25% when the system becomes fully magnetized (that is in correspondence of the upper critical value of the interaction strength) and continues to grow as the interaction strength increases

  12. Data-driven haemodynamic response function extraction using Fourier-wavelet regularised deconvolution

    NARCIS (Netherlands)

    Wink, Alle Meije; Hoogduin, Hans; Roerdink, Jos B.T.M.

    2008-01-01

    Background: We present a simple, data-driven method to extract haemodynamic response functions (HRF) from functional magnetic resonance imaging (fMRI) time series, based on the Fourier-wavelet regularised deconvolution (ForWaRD) technique. HRF data are required for many fMRI applications, such as

  13. Data-driven haemodynamic response function extraction using Fourier-wavelet regularised deconvolution

    NARCIS (Netherlands)

    Wink, Alle Meije; Hoogduin, Hans; Roerdink, Jos B.T.M.

    2010-01-01

    Background: We present a simple, data-driven method to extract haemodynamic response functions (HRF) from functional magnetic resonance imaging (fMRI) time series, based on the Fourier-wavelet regularised deconvolution (ForWaRD) technique. HRF data are required for many fMRI applications, such as

  14. Functional changes in littoral macroinvertebrate communities in response to watershed-level anthropogenic stress.

    Directory of Open Access Journals (Sweden)

    Katya E Kovalenko

    Full Text Available Watershed-scale anthropogenic stressors have profound effects on aquatic communities. Although several functional traits of stream macroinvertebrates change predictably in response to land development and urbanization, little is known about macroinvertebrate functional responses in lakes. We assessed functional community structure, functional diversity (Rao's quadratic entropy and voltinism in macroinvertebrate communities sampled across the full gradient of anthropogenic stress in Laurentian Great Lakes coastal wetlands. Functional diversity and voltinism significantly decreased with increasing development, whereas agriculture had smaller or non-significant effects. Functional community structure was affected by watershed-scale development, as demonstrated by an ordination analysis followed by regression. Because functional community structure affects energy flow and ecosystem function, and functional diversity is known to have important implications for ecosystem resilience to further environmental change, these results highlight the necessity of finding ways to remediate or at least ameliorate these effects.

  15. Item-level psychometrics of the ADL instrument of the Korean National Survey on persons with physical disabilities.

    Science.gov (United States)

    Hong, Ickpyo; Lee, Mi Jung; Kim, Moon Young; Park, Hae Yean

    2017-10-01

    The aim of this study is to investigate the psychometrics of the 12 items of an instrument assessing activities of daily living (ADL) using an item response theory model. A total of 648 adults with physical disabilities and having difficulties in ADLs were retrieved from the 2014 Korean National Survey on People with Disabilities. The psychometric testing included factor analysis, internal consistency, precision, and differential item functioning (DIF) across categories including sex, older age, marital status, and physical impairment area. The sample had a mean age of 69.7 years old (SD = 13.7). The majority of the sample had lower extremity impairments (62.0%) and had at least 2.1 chronic conditions. The instrument demonstrated unidimensional construct and good internal consistency (Cronbach's alpha = 0.95). The instrument precisely estimated person measures within a wide range of theta values (-2.22 logits  5.0%). Our findings indicate that the dressing item would need to be modified to improve its psychometrics. Overall, the ADL instrument demonstrates good psychometrics, and thus, it may be used as a standardized instrument for measuring disability in rehabilitation contexts. However, the findings are limited to adults with physical disabilities. Future studies should replicate psychometric testing for survey respondents with other disorders and for children.

  16. Dose equivalent response of personal neutron dosemeters as a function of angle

    International Nuclear Information System (INIS)

    Tanner, J.E.; McDonald, J.C.; Stewart, R.D.; Wernli, C.

    1997-01-01

    The measured and calculated dose equivalent response as a function of angle has been examined for an albedo-type thermoluminescence dosemeter (TLD) that was exposed to unmoderated and D 2 O-moderated 252 Cf neutron sources while mounted on a 40 x 40 15 cm 3 polymethylmethacrylate phantom. The dosemeter used in this study is similar to many neutron personal dosemeters currently in use. The detailed construction of the dosemeter was modelled, and the dose equivalent response was calculated, using the MCNP code. Good agreement was found between the measured and calculated values of the relative dose equivalent angular response for the TLD albedo dosemeter. The relative dose equivalent angular response was also compared with the values of directional and personal dose equivalent as a function of angle published by Siebert and Schuhmacher. (author)

  17. Validation of a quality-of-life instrument for patients with nonmelanoma skin cancer.

    Science.gov (United States)

    Rhee, John S; Matthews, B Alex; Neuburg, Marcy; Logan, Brent R; Burzynski, Mary; Nattinger, Ann B

    2006-01-01

    To validate a disease-specific quality-of-life instrument--the Skin Cancer Index--intended to measure quality-of-life issues relevant to patients with nonmelanoma skin cancer. Internal reliability, convergent and divergent validity with existing scales, and factor analyses were performed in a cross-sectional study of 211 patients presenting with cervicofacial nonmelanoma skin cancer to a dermatologic surgery clinic. Factor analyses of the Skin Cancer Index confirmed a multidimensional scale with 3 distinct subscales-emotional, social, and appearance. Excellent internal validity of the 3 subscales was demonstrated. Substantial evidence was observed for convergent validity with the Dermatology Life Quality Index, Rosenberg Self-Esteem Scale, Lerman's Cancer Worry Scale, and Medical Outcomes Survey Short-Form 12 domains for vitality, emotion, social function, and mental health. These findings validate a new disease-specific quality-of-life instrument for patients with cervicofacial nonmelanoma skin cancer. Studies on the responsiveness of the Skin Cancer Index to clinical intervention are currently under way.

  18. Calculation and applications of the frequency dependent neutron detector response functions

    International Nuclear Information System (INIS)

    Van Dam, H.; Van Hagen, T.H.J.J. der; Hoogenboom, J.E.; Keijzer, J.

    1994-01-01

    The theoretical basis is presented for the evaluation of the frequency dependent function that enables to calculate the response of a neutron detector to parametric fluctuations ('noise') or oscillations in reactor core. This function describes the 'field view' of a detector and can be calculated with a static transport code under certain conditions which are discussed. Two applications are presented: the response of an ex-core detector to void fraction fluctuations in a BWR and of both in and ex-core detectors to a rotating neutron absorber near or inside a research reactor core. (authors). 7 refs., 4 figs

  19. Measurements with the new PHE neutron survey instrument

    International Nuclear Information System (INIS)

    Eakins, J.S.; Tanner, R.J.; Hager, L.G.

    2014-01-01

    A novel design of survey instrument has been developed to accurately estimate ambient dose equivalent from neutrons with energies in the range from thermal to 20 MeV. The device features moderating and attenuating layers to ease measurement of fast and intermediate energy neutrons, combined with guides that channel low-energy neutrons to the single, central detector. A prototype of this device has been constructed and exposed to a set of calibration fields: the resulting measured responses are presented and discussed here, and compared against Monte Carlo data. A simple simulated workplace neutron field has also been developed to test the device. Measured response data have been determined for a prototype design of neutron survey instrument, using facilities at PHE and NPL. In general, the results demonstrated good directional invariance and agreed well with data obtained by Monte Carlo modelling, raising confidence in the accuracy of the response characteristics expected for the device. A simple simulated workplace field has also been developed and characterised, and the performance of the device assessed in it: agreement between measured and modelled results suggests that the device would behave as anticipated in real workplace fields. These performances will be investigated further in the future, as the design makes the transition from a research prototype to a commercially available instrument. (authors)

  20. The out of equilibrium response function in sub-diffusive systems

    International Nuclear Information System (INIS)

    Gradenigo, G; Puglisi, A; Sarracino, A; Vulpiani, A; Villamaina, D

    2012-01-01

    We study the Einstein relation between spontaneous fluctuations and the response to an external perturbation for the comb model and the single file, which are examples of systems with sub-diffusive transport properties. The relevance of nonequilibrium conditions is investigated: when a stationary current (in the form of a drift or an energy flux) is present, the Einstein relation breaks down. In the case of the comb model, a general relation - appearing in the recent literature - between the response function and an unperturbed suitable correlation function allows us to explain the obtained results. This suggests that the relevant ingredient in breaking the Einstein formula, for stationary regimes, is not anomalous diffusion but the presence of currents driving the system out of equilibrium.

  1. The Italian version of cognitive function instrument (CFI): reliability and validity in a cohort of healthy elderly.

    Science.gov (United States)

    Chipi, Elena; Frattini, Giulia; Eusebi, Paolo; Mollica, Anita; D'Andrea, Katia; Russo, Mirella; Bernardelli, Alice; Montanucci, Chiara; Luchetti, Elisa; Calabresi, Paolo; Parnetti, Lucilla

    2018-01-01

    The Alzheimer's disease Cooperative Study (ADCS)-Cognitive Function Instrument (CFI) is a 14-item questionnaire administered to the subject and the referent, aimed at detecting early changes in cognitive and functional abilities in individuals without clinical impairment. It is used for monitoring annual variations in cognitive functioning in prevention trials. The aim of the present study was to validate the Italian version of the CFI. A consecutive series of 257 functionally independent subjects was recruited among relatives of patients or as volunteers. They were administered CFI and global cognition measurements: Mini-Mental Status Examination (MMSE) and Repeatable Battery for the Assessment of Neuropsychological Status (RBANS). The reliability and criterion validity were comparable to the original in both self- and partner-report. Similarly to what reported in the original version, we found a corrected item-total correlation ranging between 0.38 and 0.54 in self-report and between 0.33 and 0.64 in partner-report. Cronbach's α was 0.77 (95% CI 0.72-0.83) in self-report and 0.78 (95% CI 0.73-0.84) in partner-report. Total partner- and self-report scores were significantly correlated (rS = 0.31, p reliability and validity of the Italian version of CFI. In order to definitely propose the use of CFI for tracking longitudinal changes of cognitive and functional abilities in subjects without clinical impairment, data from the follow-up of this cohort are needed.

  2. The Pavlovian analysis of instrumental conditioning.

    Science.gov (United States)

    Gormezano, I; Tait, R W

    1976-01-01

    An account was given of the development within the Russian literature of a uniprocess formulation of classical and instrumental conditioning, known as the bidirectional conditioning hypothesis. The hypothesis purports to offer a single set of Pavlovian principles to account for both paradigms, based upon a neural model which assumes that bidirectional (forward and backward) connections are formed in both calssical and instrumental conditioning situations. In instrumental conditioning, the bidirectional connections are hypothesized to be simply more complex than those in classical conditioning, and any differences in empirical functions are presumed to lie not in difference in mechanism, but in the strength of the forward and backward connections. Although bidirectional connections are assumed to develop in instrumental conditioning, the experimental investigation of the bidirectional conditioning hypothesis has been essentially restricted to the classical conditioning operations of pairing two CSs (sensory preconditioning training), a US followed by a CS (backward conditioning training) and two USs. However, the paradigm involving the pairing of two USs, because of theoretical and analytical considerations, is the one most commonly employed by Russian investigators. The results of an initial experiment involving the pairing of two USs, and reference to the results of a more extensive investigation, leads us to tentatively question the validity of the bidirectional conditioning account of instrumental conditioning.

  3. A Comprehensive Review of Sensors and Instrumentation Methods in Devices for Musical Expression

    Directory of Open Access Journals (Sweden)

    Carolina Brum Medeiros

    2014-07-01

    Full Text Available Digital Musical Instruments (DMIs are musical instruments typically composed of a control surface where user interaction is measured by sensors whose values are mapped to sound synthesis algorithms. These instruments have gained interest among skilled musicians and performers in the last decades leading to artistic practices including musical performance, interactive installations and dance. The creation of DMIs typically involves several areas, among them: arts, design and engineering. The balance between these areas is an essential task in DMI design so that the resulting instruments are aesthetically appealing, robust, and allow responsive, accurate and repeatable sensing. In this paper, we review the use of sensors in the DMI community as manifested in the proceedings of the International Conference on New Interfaces for Musical Expression (NIME 2009–2013. Focusing on the sensor technologies and signal conditioning techniques used by the NIME community. Although it has been claimed that specifications for artistic tools are harder than those for military applications, this study raises a paradox showing that in most of the cases, DMIs are based on a few basic sensors types and unsophisticated engineering solutions, not taking advantage of more advanced sensing, instrumentation and signal processing techniques that could dramatically improve their response. We aim to raise awareness of limitations of any engineering solution and to assert the benefits of advanced electronics instrumentation design in DMIs. For this, we propose the use of specialized sensors such as strain gages, advanced conditioning circuits and signal processing tools such as sensor fusion. We believe that careful electronic instrumentation design may lead to more responsive instruments.

  4. Exploiting IoT Technologies and Open Source Components for Smart Seismic Network Instrumentation

    Science.gov (United States)

    Germenis, N. G.; Koulamas, C. A.; Foundas, P. N.

    2017-12-01

    The data collection infrastructure of any seismic network poses a number of requirements and trade-offs related to accuracy, reliability, power autonomy and installation & operational costs. Having the right hardware design at the edge of this infrastructure, embedded software running inside the instruments is the heart of pre-processing and communication services implementation and their integration with the central storage and processing facilities of the seismic network. This work demonstrates the feasibility and benefits of exploiting software components from heterogeneous sources in order to realize a smart seismic data logger, achieving higher reliability, faster integration and less development and testing costs of critical functionality that is in turn responsible for the cost and power efficient operation of the device. The instrument's software builds on top of widely used open source components around the Linux kernel with real-time extensions, the core Debian Linux distribution, the earthworm and seiscomp tooling frameworks, as well as components from the Internet of Things (IoT) world, such as the CoAP and MQTT protocols for the signaling planes, besides the widely used de-facto standards of the application domain at the data plane, such as the SeedLink protocol. By using an innovative integration of features based on lower level GPL components of the seiscomp suite with higher level processing earthworm components, coupled with IoT protocol extensions to the latter, the instrument can implement smart functionality such as network controlled, event triggered data transmission in parallel with edge archiving and on demand, short term historical data retrieval.

  5. Design of a TFT-LCD Based Digital Automobile Instrument

    Directory of Open Access Journals (Sweden)

    Yunsong Xu

    2014-01-01

    instrument and gives an introduction to the sampling circuits and interfaces related to these signals. Following this is the functional categorizing of the circuit modules, such as video buffer circuit, CAN bus interface circuit, and TFT-LCD drive circuit. Additionally, the external EEPROM stores information of the vehicle for history data query, and the external FLASH enables the display of high quality figures. On the whole, the accomplished automobile instrument meets the requirements of automobile instrument markets with its characters of low cost, favorable compatibility, friendly interfaces, and easy upgrading.

  6. Policy Instruments to Improve Energy Performance of Existing Owner Occupied Dwellings

    Directory of Open Access Journals (Sweden)

    Lorraine Colette Murphy

    2016-11-01

    has increased due to, inter alia, the realization that the revolution in energy use that must occur for climate change targets to be met means major changes in the fabric of the existing dwelling stock, dwellings constructed before building regulations demanded high energy performance standards. It is argued that the building sector, in general, and the existing dwelling stock, in particular, can contribute more cost effectively and more significantly in quality and quantity terms than any other sector (Amstalden et al., 2007; Lomas, 2010; Ürge-Vorsatz, et al., 2007. This has provoked calls for new and improved instruments to meet the energy saving potential of existing dwellings. Despite many of the same instruments being used for decades there is little solid information on many crucial dimensions of how instruments operate and on what impact they have. The few evaluations and reviews that do take place are commonly focused on theoretical energy savings and costs and instrument strengths and weaknesses. Instruments commonly appear and disappear without undergoing improvement or change or contributing to policy learning. Many instruments are laden with assumptions about the target group that are never formally or comprehensively proved or debunked. Little theorizing takes place on the type of instruments most suited to the target group. Fundamentally, there is a serious lack of information surrounding the effectiveness of instruments assumed to be making climate change targets a reality. It is the above mentioned information deficits that influenced the objectives and structure of this thesis. Instruments are examined from different angles and viewpoints, from experts, owner occupiers, official evaluations and front-runner countries. Assessment frameworks were developed to tease out how well instruments truly function. Households in receipt of instruments such as the EPC and energy audit were compared to households not in receipt of instruments. Moreover, the

  7. Technological considerations in emergency instrumentation preparedness. Phase II-D. Evaluation testing and calibration methodology for emergency radiological instrumentation

    International Nuclear Information System (INIS)

    Bramson, P.E.; Andersen, B.V.; Fleming, D.M.; Kathren, R.L.; Mulhern, O.R.; Newton, C.E.; Oscarson, E.E.; Selby, J.M.

    1976-09-01

    In response to recommendations from the Advisory Committee on Reactor Safeguards, the Division of Operational Safety, U.S. ERDA has contracted with Battelle, Pacific Northwest Laboratories to survey the adequacy of existing instrumentation at nuclear fuel cycle facilities to meet emergency requirements and to develop technical criteria for instrumentation systems to be used in assessment of environmental conditions following plant emergencies. This report, the fifth in a series, provides: (1) calibration methods to assure the quality of radiological measurements and (2) testing procedures for determining whether an emergency radiological instrument meets the performance specifications. Three previous reports in this series identified the emergency instrumentation needs for power reactors, mixed oxide fuel plants, and fuel reprocessing facilities. Each of these three reports contains a Section VI, which sets forth applicable radiological instrument performance criteria and calibration requirements. Testing and calibration procedures in this report have been formatted in two parts: IV and V, each divided into three subsections: (1) Power Reactors, (2) Mixed Oxide Fuel Plants, and (3) Fuel Reprocessing Facilities. The three performance criteria subsections directly coincide with the performance criteria sections of the previous reports. These performance criteria sections have been reproduced in this report as Part III with references of ''required action'' added

  8. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  9. MECs: "Building Blocks" for Creating Biological and Chemical Instruments.

    Directory of Open Access Journals (Sweden)

    Douglas A Hill

    Full Text Available The development of new biological and chemical instruments for research and diagnostic applications is often slowed by the cost, specialization, and custom nature of these instruments. New instruments are built from components that are drawn from a host of different disciplines and not designed to integrate together, and once built, an instrument typically performs a limited number of tasks and cannot be easily adapted for new applications. Consequently, the process of inventing new instruments is very inefficient, especially for researchers or clinicians in resource-limited settings. To improve this situation, we propose that a family of standardized multidisciplinary components is needed, a set of "building blocks" that perform a wide array of different tasks and are designed to integrate together. Using these components, scientists, engineers, and clinicians would be able to build custom instruments for their own unique needs quickly and easily. In this work we present the foundation of this set of components, a system we call Multifluidic Evolutionary Components (MECs. "Multifluidic" conveys the wide range of fluid volumes MECs operate upon (from nanoliters to milliliters and beyond; "multi" also reflects the multiple disciplines supported by the system (not only fluidics but also electronics, optics, and mechanics. "Evolutionary" refers to the design principles that enable the library of MEC parts to easily grow and adapt to new applications. Each MEC "building block" performs a fundamental function that is commonly found in biological or chemical instruments, functions like valving, pumping, mixing, controlling, and sensing. Each MEC also has a unique symbol linked to a physical definition, which enables instruments to be designed rapidly and efficiently using schematics. As a proof-of-concept, we use MECs to build a variety of instruments, including a fluidic routing and mixing system capable of manipulating fluid volumes over five orders

  10. THE KEPLER PIXEL RESPONSE FUNCTION

    International Nuclear Information System (INIS)

    Bryson, Stephen T.; Haas, Michael R.; Dotson, Jessie L.; Koch, David G.; Borucki, William J.; Tenenbaum, Peter; Jenkins, Jon M.; Chandrasekaran, Hema; Caldwell, Douglas A.; Klaus, Todd; Gilliland, Ronald L.

    2010-01-01

    Kepler seeks to detect sequences of transits of Earth-size exoplanets orbiting solar-like stars. Such transit signals are on the order of 100 ppm. The high photometric precision demanded by Kepler requires detailed knowledge of how the Kepler pixels respond to starlight during a nominal observation. This information is provided by the Kepler pixel response function (PRF), defined as the composite of Kepler's optical point-spread function, integrated spacecraft pointing jitter during a nominal cadence and other systematic effects. To provide sub-pixel resolution, the PRF is represented as a piecewise-continuous polynomial on a sub-pixel mesh. This continuous representation allows the prediction of a star's flux value on any pixel given the star's pixel position. The advantages and difficulties of this polynomial representation are discussed, including characterization of spatial variation in the PRF and the smoothing of discontinuities between sub-pixel polynomial patches. On-orbit super-resolution measurements of the PRF across the Kepler field of view are described. Two uses of the PRF are presented: the selection of pixels for each star that maximizes the photometric signal-to-noise ratio for that star, and PRF-fitted centroids which provide robust and accurate stellar positions on the CCD, primarily used for attitude and plate scale tracking. Good knowledge of the PRF has been a critical component for the successful collection of high-precision photometry by Kepler.

  11. Development of quality control and instrumentation performance metrics for diffuse optical spectroscopic imaging instruments in the multi-center clinical environment

    Science.gov (United States)

    Keene, Samuel T.; Cerussi, Albert E.; Warren, Robert V.; Hill, Brian; Roblyer, Darren; Leproux, AnaÑ--s.; Durkin, Amanda F.; O'Sullivan, Thomas D.; Haghany, Hosain; Mantulin, William W.; Tromberg, Bruce J.

    2013-03-01

    Instrument equivalence and quality control are critical elements of multi-center clinical trials. We currently have five identical Diffuse Optical Spectroscopic Imaging (DOSI) instruments enrolled in the American College of Radiology Imaging Network (ACRIN, #6691) trial located at five academic clinical research sites in the US. The goal of the study is to predict the response of breast tumors to neoadjuvant chemotherapy in 60 patients. In order to reliably compare DOSI measurements across different instruments, operators and sites, we must be confident that the data quality is comparable. We require objective and reliable methods for identifying, correcting, and rejecting low quality data. To achieve this goal, we developed and tested an automated quality control algorithm that rejects data points below the instrument noise floor, improves tissue optical property recovery, and outputs a detailed data quality report. Using a new protocol for obtaining dark-noise data, we applied the algorithm to ACRIN patient data and successfully improved the quality of recovered physiological data in some cases.

  12. Challenges of metal recycling and an international covenant as possible instrument of a globally extended producer responsibility.

    Science.gov (United States)

    Wilts, Hennning; Bringezu, Stefan; Bleischwitz, Raimund; Lucas, Rainer; Wittmer, Dominic

    2011-09-01

    As illustrated by the case studies of end-of-life vehicles and waste electric and electronic equipment, the approach of an extended producer responsibility is undermined by the exports of used and waste products. This fact causes severe deficits regarding circular flows, especially of critical raw materials such as platinum group metals. With regard to global recycling there seems to be a responsibility gap which leads somehow to open ends of waste flows and a loss or down-cycling of potential secondary resources. Existing product-orientated extended producer responsibility (EPR) approaches with mass-based recycling quotas do not create adequate incentives to supply waste materials containing precious metals to a high-quality recycling and should be amended by aspects of a material stewardship. The paper analyses incentive effects on EPR for the mentioned product groups and metals, resulting from existing regulations in Germany. It develops a proposal for an international covenant on metal recycling as a policy instrument for a governance-oriented framework to initiate systemic innovations along the complete value chain taking into account product group- and resource group-specific aspects on different spatial levels. It aims at the effective implementation of a central idea of EPR, the transition of a waste regime still focusing on safe disposal towards a sustainable management of resources for the complete lifecycle of products.

  13. Dual function of CD70 in viral infection: modulator of early cytokine responses and activator of adaptive responses1

    OpenAIRE

    Allam, Atef; Swiecki, Melissa; Vermi, William; Ashwell, Jonathan D.; Colonna, Marco

    2014-01-01

    The role of the tumor necrosis factor family member CD70 in adaptive T cell responses has been intensively studied but its function in innate responses is still under investigation. Here we show that CD70 inhibits the early innate response to murine cytomegalovirus (MCMV) but is essential for the optimal generation of virus-specific CD8 T cells. CD70-/- mice reacted to MCMV infection with a robust type I interferon and proinflammatory cytokine response. This response was sufficient for initia...

  14. Quality assurance of radiation protection monitoring instruments in India

    International Nuclear Information System (INIS)

    Tripathi, S.M.; Daniel, Liji; Rao, Suresh; Sharma, D.N.

    2008-01-01

    Bhabha Atomic Research Centre (BARC) is the National Metrology Institute (NMI) for developing, maintaining and disseminating standards for ionizing radiation in India. Radiation Safety Systems Division (RSSD) of BARC has the requisite infrastructure in the form of experts, trained manpower, laboratories, equipment and facilities for providing calibration services to users and ascertaining traceability to international standards. It periodically participates in various international inter-comparisons. RSSD maintains reference radiation fields that are required for calibrating Radiation Protection Monitoring Instruments that form the backbone of the radiation monitoring programme for harnessing the benefits of nuclear energy and ionizing radiations. These instruments are type-tested and periodically calibrated at standard reference radiation fields to ensure their healthy working condition and fitness for their intended use. This paper describes the details of the standardization procedures adopted for reference radiation fields and infrastructure established and maintained at RSSD, BARC in accordance with the recommendations of ISO-4037. The paper describes the various tests that are carried out for radiation protection monitoring instrument to study the variation of the calibration factor with influencing quantities like linearity of response, energy response, angular dependence and overload characteristics. The results of these tests for typical instruments are also discussed. The present work also describes various types of indigenously developed radiation protection monitoring instruments and their performance characteristics. Adaptability of these instruments for the implementation of operational quantities are discussed briefly. It also dwells on the IAEA Quality Audit for radiation protection level calibrations, which RSSD has been participating since 2001. Our results of the quality audit are well within the acceptance limit (±7%) set by IAEA for the

  15. Dual function of CD70 in viral infection: modulator of early cytokine responses and activator of adaptive responses1

    Science.gov (United States)

    Allam, Atef; Swiecki, Melissa; Vermi, William; Ashwell, Jonathan D.; Colonna, Marco

    2014-01-01

    The role of the tumor necrosis factor family member CD70 in adaptive T cell responses has been intensively studied but its function in innate responses is still under investigation. Here we show that CD70 inhibits the early innate response to murine cytomegalovirus (MCMV) but is essential for the optimal generation of virus-specific CD8 T cells. CD70-/- mice reacted to MCMV infection with a robust type I interferon and proinflammatory cytokine response. This response was sufficient for initial control of MCMV, although at later time points, CD70-/- mice became more susceptible to MCMV infection. The heightened cytokine response during the early phase of MCMV infection in CD70-/- mice was paralleled by a reduction in regulatory T cells (Treg). Treg from naïve CD70-/- mice were not as efficient at suppressing T cell proliferation compared to Treg from naïve WT mice and depletion of Treg during MCMV infection in Foxp3-DTR mice or in WT mice recapitulated the phenotype observed in CD70-/- mice. Our study demonstrates that while CD70 is required for the activation of the antiviral adaptive response, it has a regulatory role in early cytokine responses to viruses such as MCMV, possibly through maintenance of Treg survival and function. PMID:24913981

  16. Instrument Remote Control via the Astronomical Instrument Markup Language

    Science.gov (United States)

    Sall, Ken; Ames, Troy; Warsaw, Craig; Koons, Lisa; Shafer, Richard

    1998-01-01

    The Instrument Remote Control (IRC) project ongoing at NASA's Goddard Space Flight Center's (GSFC) Information Systems Center (ISC) supports NASA's mission by defining an adaptive intranet-based framework that provides robust interactive and distributed control and monitoring of remote instruments. An astronomical IRC architecture that combines the platform-independent processing capabilities of Java with the power of Extensible Markup Language (XML) to express hierarchical data in an equally platform-independent, as well as human readable manner, has been developed. This architecture is implemented using a variety of XML support tools and Application Programming Interfaces (API) written in Java. IRC will enable trusted astronomers from around the world to easily access infrared instruments (e.g., telescopes, cameras, and spectrometers) located in remote, inhospitable environments, such as the South Pole, a high Chilean mountaintop, or an airborne observatory aboard a Boeing 747. Using IRC's frameworks, an astronomer or other scientist can easily define the type of onboard instrument, control the instrument remotely, and return monitoring data all through the intranet. The Astronomical Instrument Markup Language (AIML) is the first implementation of the more general Instrument Markup Language (IML). The key aspects of our approach to instrument description and control applies to many domains, from medical instruments to machine assembly lines. The concepts behind AIML apply equally well to the description and control of instruments in general. IRC enables us to apply our techniques to several instruments, preferably from different observatories.

  17. Functional and structural responses to marine urbanisation

    Science.gov (United States)

    Mayer-Pinto, M.; Cole, V. J.; Johnston, E. L.; Bugnot, A.; Hurst, H.; Airoldi, L.; Glasby, T. M.; Dafforn, K. A.

    2018-01-01

    Urban areas have broad ecological footprints with complex impacts on natural systems. In coastal areas, growing populations are advancing their urban footprint into the ocean through the construction of seawalls and other built infrastructure. While we have some understanding of how urbanisation might drive functional change in terrestrial ecosystems, coastal systems have been largely overlooked. This study is one of the first to directly assess how changes in diversity relate to changes in ecosystem properties and functions (e.g. productivity, filtration rates) of artificial and natural habitats in one of the largest urbanised estuaries in the world, Sydney Harbour. We complemented our surveys with an extensive literature search. We found large and important differences in the community structure and function between artificial and natural coastal habitats. However, differences in diversity and abundance of organisms do not necessarily match observed functional changes. The abundance and composition of important functional groups differed among habitats with rocky shores having 40% and 70% more grazers than seawalls or pilings, respectively. In contrast, scavengers were approximately 8 times more abundant on seawalls than on pilings or rocky shores and algae were more diverse on natural rocky shores and seawalls than on pilings. Our results confirm previous findings in the literature. Oysters were more abundant on pilings than on rocky shores, but were also smaller. Interestingly, these differences in oyster populations did not affect in situ filtration rates between habitats. Seawalls were the most invaded habitats while pilings supported greater secondary productivity than other habitats. This study highlights the complexity of the diversity-function relationship and responses to ocean sprawl in coastal systems. Importantly, we showed that functional properties should be considered independently from structural change if we are to design and manage artificial

  18. [French residents' training in instrumental deliveries: A national survey].

    Science.gov (United States)

    Saunier, C; Raimond, E; Dupont, A; Pelissier, A; Bonneau, S; Gabriel, R; Graesslin, O

    2016-11-01

    To evaluate French residents in Obstetrics and Gynaecology's training in instrumental deliveries in 2015. We conducted a national descriptive survey among 758 residents between December 2014 and January 2015. Respondents were invited by email to specify their University Hospital, their current university term, the number of instrumental deliveries performed by vacuum extractor, forceps or spatulas, and whether they made systematic ultrasound exams before performing the extraction. Response rate was 34.7 % (n=263). There were important differences between regions in terms of type of instruments used. Vacuum extractor was the most commonly used instrument for instrumental deliveries by French residents (56.9 %), more than forceps (25.2 %) and spatulas (17.9 %). At the end of the residency, all the residents had been trained in instrumental deliveries with at least two instruments. The training of difficult techniques as well as their perfect control is required for instrumental deliveries. Yet, we are forced to note that there are substantial differences in the French residents' training in instrumental deliveries depending on their region. So, teaching at least two techniques seems essential as well as improving the training capacities and standardizing practices. A greater systematization of the teaching of the mechanics and obstetric techniques might be a solution to be considered too. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  19. Using frequency response functions to manage image degradation from equipment vibration in the Daniel K. Inouye Solar Telescope

    Science.gov (United States)

    McBride, William R.; McBride, Daniel R.

    2016-08-01

    The Daniel K Inouye Solar Telescope (DKIST) will be the largest solar telescope in the world, providing a significant increase in the resolution of solar data available to the scientific community. Vibration mitigation is critical in long focal-length telescopes such as the Inouye Solar Telescope, especially when adaptive optics are employed to correct for atmospheric seeing. For this reason, a vibration error budget has been implemented. Initially, the FRFs for the various mounting points of ancillary equipment were estimated using the finite element analysis (FEA) of the telescope structures. FEA analysis is well documented and understood; the focus of this paper is on the methods involved in estimating a set of experimental (measured) transfer functions of the as-built telescope structure for the purpose of vibration management. Techniques to measure low-frequency single-input-single-output (SISO) frequency response functions (FRF) between vibration source locations and image motion on the focal plane are described. The measurement equipment includes an instrumented inertial-mass shaker capable of operation down to 4 Hz along with seismic accelerometers. The measurement of vibration at frequencies below 10 Hz with good signal-to-noise ratio (SNR) requires several noise reduction techniques including high-performance windows, noise-averaging, tracking filters, and spectral estimation. These signal-processing techniques are described in detail.

  20. Food supply and demand, a simulation model of the functional response of grazing ruminants

    NARCIS (Netherlands)

    Smallegange, I.M.; Brunsting, A.M.H.

    2002-01-01

    A dynamic model of the functional response is a first prerequisite to be able to bridge the gap between local feeding ecology and grazing rules that pertain to larger scales. A mechanistic model is presented that simulates the functional response, growth and grazing time of ruminants. It is based on

  1. Selective neurophysiologic responses to music in instrumentalists with different listening biographies.

    Science.gov (United States)

    Margulis, Elizabeth Hellmuth; Mlsna, Lauren M; Uppunda, Ajith K; Parrish, Todd B; Wong, Patrick C M

    2009-01-01

    To appropriately adapt to constant sensory stimulation, neurons in the auditory system are tuned to various acoustic characteristics, such as center frequencies, frequency modulations, and their combinations, particularly those combinations that carry species-specific communicative functions. The present study asks whether such tunings extend beyond acoustic and communicative functions to auditory self-relevance and expertise. More specifically, we examined the role of the listening biography--an individual's long term experience with a particular type of auditory input--on perceptual-neural plasticity. Two groups of expert instrumentalists (violinists and flutists) listened to matched musical excerpts played on the two instruments (J.S. Bach Partitas for solo violin and flute) while their cerebral hemodynamic responses were measured using fMRI. Our experimental design allowed for a comprehensive investigation of the neurophysiology (cerebral hemodynamic responses as measured by fMRI) of auditory expertise (i.e., when violinists listened to violin music and when flutists listened to flute music) and nonexpertise (i.e., when subjects listened to music played on the other instrument). We found an extensive cerebral network of expertise, which implicates increased sensitivity to musical syntax (BA 44), timbre (auditory association cortex), and sound-motor interactions (precentral gyrus) when listening to music played on the instrument of expertise (the instrument for which subjects had a unique listening biography). These findings highlight auditory self-relevance and expertise as a mechanism of perceptual-neural plasticity, and implicate neural tuning that includes and extends beyond acoustic and communication-relevant structures. (c) 2007 Wiley-Liss, Inc.

  2. Altered functional magnetic resonance imaging responses to nonpainful sensory stimulation in fibromyalgia patients.

    Science.gov (United States)

    López-Solà, Marina; Pujol, Jesus; Wager, Tor D; Garcia-Fontanals, Alba; Blanco-Hinojo, Laura; Garcia-Blanco, Susana; Poca-Dias, Violant; Harrison, Ben J; Contreras-Rodríguez, Oren; Monfort, Jordi; Garcia-Fructuoso, Ferran; Deus, Joan

    2014-11-01

    Fibromyalgia (FM) is a disorder characterized by chronic pain and enhanced responses to acute noxious events. However, the sensory systems affected in FM may extend beyond pain itself, as FM patients show reduced tolerance to non-nociceptive sensory stimulation. Characterizing the neural substrates of multisensory hypersensitivity in FM may thus provide important clues about the underlying pathophysiology of the disorder. The aim of this study was to characterize brain responses to non-nociceptive sensory stimulation in FM patients and their relationship to subjective sensory sensitivity and clinical pain severity. Functional magnetic resonance imaging (MRI) was used to assess brain response to auditory, visual, and tactile motor stimulation in 35 women with FM and 25 matched controls. Correlation and mediation analyses were performed to establish the relationship between brain responses and 3 types of outcomes: subjective hypersensitivity to daily sensory stimulation, spontaneous pain, and functional disability. Patients reported increased subjective sensitivity (increased unpleasantness) in response to multisensory stimulation in daily life. Functional MRI revealed that patients showed reduced task-evoked activation in primary/secondary visual and auditory areas and augmented responses in the insula and anterior lingual gyrus. Reduced responses in visual and auditory areas were correlated with subjective sensory hypersensitivity and clinical severity measures. FM patients showed strong attenuation of brain responses to nonpainful events in early sensory cortices, accompanied by an amplified response at later stages of sensory integration in the insula. These abnormalities are associated with core FM symptoms, suggesting that they may be part of the pathophysiology of the disease. Copyright © 2014 by the American College of Rheumatology.

  3. Mitochondrial respiration controls lysosomal function during inflammatory T cell responses

    Science.gov (United States)

    Baixauli, Francesc; Acín-Pérez, Rebeca; Villarroya-Beltrí, Carolina; Mazzeo, Carla; Nuñez-Andrade, Norman; Gabandé-Rodriguez, Enrique; Dolores Ledesma, Maria; Blázquez, Alberto; Martin, Miguel Angel; Falcón-Pérez, Juan Manuel; Redondo, Juan Miguel; Enríquez, Jose Antonio; Mittelbrunn, Maria

    2016-01-01

    Summary The endolysosomal system is critical for the maintenance of cellular homeostasis. However, how endolysosomal compartment is regulated by mitochondrial function is largely unknown. We have generated a mouse model with defective mitochondrial function in CD4+ T lymphocytes by genetic deletion of the mitochondrial transcription factor A (Tfam). Mitochondrial respiration-deficiency impairs lysosome function, promotes p62 and sphingomyelin accumulation and disrupts endolysosomal trafficking pathways and autophagy, thus linking a primary mitochondrial dysfunction to a lysosomal storage disorder. The impaired lysosome function in Tfam-deficient cells subverts T cell differentiation toward pro-inflammatory subsets and exacerbates the in vivo inflammatory response. Restoration of NAD+ levels improves lysosome function and corrects the inflammatory defects in Tfam-deficient T cells. Our results uncover a mechanism by which mitochondria regulate lysosome function to preserve T cell differentiation and effector functions, and identify novel strategies for intervention in mitochondrial-related diseases. PMID:26299452

  4. Biological response to purification and acid functionalization of carbon nanotubes

    Science.gov (United States)

    Figarol, Agathe; Pourchez, Jérémie; Boudard, Delphine; Forest, Valérie; Tulliani, Jean-Marc; Lecompte, Jean-Pierre; Cottier, Michèle; Bernache-Assollant, Didier; Grosseau, Philippe

    2014-07-01

    Acid functionalization has been considered as an easy way to enhance the dispersion and biodegradation of carbon nanotubes (CNT). However, inconsistencies between toxicity studies of acid functionalized CNT remain unexplained. This could be due to a joint effect of the main physicochemical modifications resulting from an acid functionalization: addition of surface acid groups and purification from catalytic metallic impurities. In this study, the impact on CNT biotoxicity of these two physiochemical features was assessed separately. The in vitro biological response of RAW 264.7 macrophages was evaluated after exposure to 15-240 µg mL-1 of two types of multi-walled CNT. For each type of CNT (small: 20 nm diameter, and big: 90 nm diameter), three different surface chemical properties were studied (total of six CNT samples): pristine, acid functionalized and desorbed. Desorbed CNT were purified by the acid functionalization but presented a very low amount of surface acid groups due to a thermal treatment under vacuum. A Janus effect of acid functionalization with two opposite impacts is highlighted. The CNT purification decreased the overall toxicity, while the surface acid groups intensified it when present at a specific threshold. These acid groups especially amplified the pro-inflammatory response. The threshold mechanism which seemed to regulate the impact of acid groups should be further studied to determine its value and potential link to the other physicochemical state of the CNT. The results suggest that, for a safer-design approach, the benefit-risk balance of an acid functionalization has to be considered, depending on the CNT primary state of purification. Further research should be conducted in this direction.

  5. Resting state functional connectivity predicts neurofeedback response

    Directory of Open Access Journals (Sweden)

    Dustin eScheinost

    2014-09-01

    Full Text Available Tailoring treatments to the specific needs and biology of individual patients – personalized medicine – requires delineation of reliable predictors of response. Unfortunately, these have been slow to emerge, especially in neuropsychiatric disorders. We have recently described a real-time functional magnetic resonance imaging (rt-fMRI neurofeedback protocol that can reduce contamination-related anxiety, a prominent symptom of many cases of obsessive-compulsive disorder (OCD. Individual response to this intervention is variable. Here we used patterns of brain functional connectivity, as measured by baseline resting-state fMRI (rs-fMRI, to predict improvements in contamination anxiety after neurofeedback training. Activity of a region of the orbitofrontal cortex (OFC and anterior prefrontal cortex, Brodmann area (BA 10, associated with contamination anxiety in each subject was measured in real time and presented as a neurofeedback signal, permitting subjects to learn to modulate this target brain region. We have previously reported both enhanced OFC/BA 10 control and improved anxiety in a group of subclinically anxious subjects after neurofeedback. Five individuals with contamination-related OCD who underwent the same protocol also showed improved clinical symptomatology. In both groups, these behavioral improvements were strongly correlated with baseline whole-brain connectivity in the OFC/BA 10, computed from rs-fMRI collected several days prior to neurofeedback training. These pilot data suggest that rs-fMRI can be used to identify individuals likely to benefit from rt-fMRI neurofeedback training to control contamination anxiety.

  6. Quality charter. Instrumentation of solar and wind powered electricity generating systems in isolated sites. A preliminary functional analysis; Charte de qualite. Instrumentation des systemes de production d`electricite en sites isoles a base d`energie photovoltaique et eolienne. Premiere analyse fonctionnelle

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, A.; Mauras, P.; Jacquin, P.

    1996-10-01

    This document is intended to become one of the Quality Charter documents. It presents the functions which must be provided by the instrumentation systems designed for use in solar and wind powered electricity generating systems in isolated designed for use in solar and wind powered electricity generating systems in isolated sites and should be viewed in close conjunction with the `Typology` and `Energy Management` documents covering the same systems of electricity generation in isolated sites; Together, these documents provide the definition of a range of eight energy management systems and four instrumentation systems specially adapted to the different types of facilities and requirements. (authors)

  7. A user interface on networked workstations for MFTF-B plasma diagnostic instruments

    International Nuclear Information System (INIS)

    Balch, T.R.; Renbarger, V.L.

    1986-01-01

    A network of Sun-2/170 workstations is used to provide an interface to the MFTF-B Plasma Diagnostics System at Lawrence Livermore National Laboratory. The Plasma Diagnostics System (PDS) is responsible for control of MFTF-B plasma diagnostic instrumentation. An EtherNet Local Area Network links the workstations to a central multiprocessing system which furnishes data processing, data storage and control services for PDS. These workstations permit a physicist to command data acquisition, data processing, instrument control, and display of results. The interface is implemented as a metaphorical desktop, which helps the operator form a mental model of how the system works. As on a real desktop, functions are provided by sheets of paper (windows on a CRT screen) called worksheets. The worksheets may be invoked by pop-up menus and may be manipulated with a mouse. These worksheets are actually tasks that communicate with other tasks running in the central computer system. By making entries in the appropriate worksheet, a physicist may specify data acquisition or processing, control a diagnostic, or view a result

  8. Development and evaluation of an instrument to measure health-related quality of life in Cuban breast cancer patients receiving radiotherapy.

    Science.gov (United States)

    Lugo, Josefina; Nápoles, Misleidy; Pérez, Inés; Ordaz, Niurka; Luzardo, Mario; Fernández, Leticia

    2014-01-01

    INTRODUCTION Although modern technology has extended the survival of breast cancer patients, treatment's adverse effects impact their health-related quality of life. Currently, no instrument exists capable of identifying the range of problems affecting breast cancer patients receiving radiotherapy in Cuba's socioeconomic and cultural context. OBJECTIVES Construct and validate an instrument to measure the effects of breast cancer and radiotherapy on health-related quality of life in Cuban patients. METHODS The study was conducted at the Oncology and Radiobiology Institute, Havana, Cuba, from January 2010 through December 2011. Inclusion criteria were: adult female, histological diagnosis of breast cancer, treated with ambulatory radiotherapy, and written informed consent; patients unable to communicate orally or in writing, or who had neurologic or psychiatric conditions were excluded. Development phase: focus groups guided by a list of questions were carried out with 50 women. The patients reported 61 problems affecting their health-related quality-of-life. A nominal group (six oncologists and two nurses) identified the same problems. A syntactic analysis of the information was performed to create items for study and measurement scales. Content validity was determined by a nominal group of seven experts using professional judgment. Another 20 patients were selected to evaluate face validity. Validation phase: the instrument was applied to 230 patients at three different points: before radiotherapy, at the end of radiotherapy and four weeks after radiotherapy was concluded. Reliability, construct validity, discriminant validity, predictive validity, interpretability and response burden were evaluated. RESULTS The final instrument developed had 33 items distributed in 4 domains: physical functioning, psychological functioning, social and family relationships, and physical and emotional adverse effects of disease and treatment. There were two discrete items: perceived

  9. Manual of functions, assignments, and responsibilities for nuclear safety: Revision 2

    Energy Technology Data Exchange (ETDEWEB)

    1994-10-15

    The FAR Manual is a convenient easy-to-use collection of the functions, assignments, and responsibilities (FARs) of DOE nuclear safety personnel. Current DOE directives, including Orders, Secretary of Energy Notices, and other assorted policy memoranda, are the source of this information and form the basis of the FAR Manual. Today, the majority of FARs for DOE personnel are contained in DOE`s nuclear safety Orders. As these Orders are converted to rules in the Code of Federal Regulations, the FAR Manual will become the sole source for information relating to the functions, assignments, responsibilities of DOE nuclear safety personnel. The FAR Manual identifies DOE directives that relate to nuclear safety and the specific DOE personnel who are responsible for implementing them. The manual includes only FARs that have been extracted from active directives that have been approved in accordance with the procedures contained in DOE Order 1321.1B.

  10. Electromagnetic and neutral-weak response functions of 4He and 12C

    Science.gov (United States)

    Lovato, A.; Gandolfi, S.; Carlson, J.; Pieper, Steven C.; Schiavilla, R.

    2015-06-01

    Background: A major goal of nuclear theory is to understand the strong interaction in nuclei as it manifests itself in terms of two- and many-body forces among the nuclear constituents, the protons and neutrons, and the interactions of these constituents with external electroweak probes via one- and many-body currents. Purpose: The objective of the present work is to calculate the quasielastic electroweak response functions in light nuclei within the realistic dynamical framework outlined above. These response functions determine the inclusive cross section as function of the lepton momentum and energy transfers. Methods: Their ab initio calculation is a very challenging quantum many-body problem, since it requires summation over the entire excitation spectrum of the nucleus and inclusion in the electroweak currents of one- and many-body terms. Green's functions Monte Carlo methods allow one to circumvent both difficulties by computing the response in imaginary time (the so-called Euclidean response) and hence summing implicitly over the bound and continuum states of the nucleus, and by implementing specific algorithms designed to deal with the complicated spin-isospin structure of nuclear many-body operators. Results: Theoretical predictions for 4He and 12C, confirmed by experiment in the electromagnetic case, show that two-body currents generate excess transverse strength from threshold to the quasielastic to the dip region and beyond. Conclusions: These results challenge the conventional picture of quasielastic inclusive scattering as being largely dominated by single-nucleon knockout processes.

  11. Instrumentation for tomograph positioning

    International Nuclear Information System (INIS)

    Frenkel, A.D.B.; Castello Branco, L.M.; Reznik, D.S.; Santos, C.A.C.; Borges, J.C.

    1986-01-01

    The COPPE's Nuclear Instrumentation Lab. has been developing researches directed towards the implementation of a Computer-Based Tomography System. Basically, the system reported in this paper can be divided into three major parts: the mechanical part, responsible for the physical movement (Stepper-Motors, table, etc.); the electronic part, which controls the mechanical part and handles the data-acquisition process (microcomputer, interfaces, etc.); and finally, the support of a software-oriented system, including control programs and information processing routines. (Author) [pt

  12. Spectral characterization of plastic scintillation detector response as a function of magnetic field strength

    Science.gov (United States)

    Simiele, E.; Kapsch, R.-P.; Ankerhold, U.; Culberson, W.; DeWerd, L.

    2018-04-01

    The purpose of this work was to characterize intensity and spectral response changes in a plastic scintillation detector (PSD) as a function of magnetic field strength. Spectra measurements as a function of magnetic field strength were performed using an optical spectrometer. The response of both a PSD and PMMA fiber were investigated to isolate the changes in response from the scintillator and the noise signal as a function of magnetic field strength. All irradiations were performed in water at a photon beam energy of 6 MV. Magnetic field strengths of (0, ±0.35, ±0.70, ±1.05, and  ±1.40) T were investigated. Four noise subtraction techniques were investigated to evaluate the impact on the resulting noise-subtracted scintillator response with magnetic field strength. The noise subtraction methods included direct spectral subtraction, the spectral method, and variants thereof. The PMMA fiber exhibited changes in response of up to 50% with magnetic field strength due to the directional light emission from \\breve{C} erenkov radiation. The PSD showed increases in response of up to 10% when not corrected for the noise signal, which agrees with previous investigations of scintillator response in magnetic fields. Decreases in the \\breve{C} erenkov light ratio with negative field strength were observed with a maximum change at  ‑1.40 T of 3.2% compared to 0 T. The change in the noise-subtracted PSD response as a function of magnetic field strength varied with the noise subtraction technique used. Even after noise subtraction, the PSD exhibited changes in response of up to 5.5% over the four noise subtraction methods investigated.

  13. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  14. Linear and non-linear dose-response functions reveal a hormetic relationship between stress and learning.

    Science.gov (United States)

    Zoladz, Phillip R; Diamond, David M

    2008-10-16

    Over a century of behavioral research has shown that stress can enhance or impair learning and memory. In the present review, we have explored the complex effects of stress on cognition and propose that they are characterized by linear and non-linear dose-response functions, which together reveal a hormetic relationship between stress and learning. We suggest that stress initially enhances hippocampal function, resulting from amygdala-induced excitation of hippocampal synaptic plasticity, as well as the excitatory effects of several neuromodulators, including corticosteroids, norepinephrine, corticotropin-releasing hormone, acetylcholine and dopamine. We propose that this rapid activation of the amygdala-hippocampus brain memory system results in a linear dose-response relation between emotional strength and memory formation. More prolonged stress, however, leads to an inhibition of hippocampal function, which can be attributed to compensatory cellular responses that protect hippocampal neurons from excitotoxicity. This inhibition of hippocampal functioning in response to prolonged stress is potentially relevant to the well-described curvilinear dose-response relationship between arousal and memory. Our emphasis on the temporal features of stress-brain interactions addresses how stress can activate, as well as impair, hippocampal functioning to produce a hormetic relationship between stress and learning.

  15. Exploring the relationships among performance-based functional ability, self-rated disability, perceived instrumental support, and depression: a structural equation model analysis.

    Science.gov (United States)

    Weil, Joyce; Hutchinson, Susan R; Traxler, Karen

    2014-11-01

    Data from the Women's Health and Aging Study were used to test a model of factors explaining depressive symptomology. The primary purpose of the study was to explore the association between performance-based measures of functional ability and depression and to examine the role of self-rated physical difficulties and perceived instrumental support in mediating the relationship between performance-based functioning and depression. The inclusion of performance-based measures allows for the testing of functional ability as a clinical precursor to disability and depression: a critical, but rarely examined, association in the disablement process. Structural equation modeling supported the overall fit of the model and found an indirect relationship between performance-based functioning and depression, with perceived physical difficulties serving as a significant mediator. Our results highlight the complementary nature of performance-based and self-rated measures and the importance of including perception of self-rated physical difficulties when examining depression in older persons. © The Author(s) 2014.

  16. Semiparametric Item Response Functions in the Context of Guessing

    Science.gov (United States)

    Falk, Carl F.; Cai, Li

    2016-01-01

    We present a logistic function of a monotonic polynomial with a lower asymptote, allowing additional flexibility beyond the three-parameter logistic model. We develop a maximum marginal likelihood-based approach to estimate the item parameters. The new item response model is demonstrated on math assessment data from a state, and a computationally…

  17. The Dif Identification in Constructed Response Items Using Partial Credit Model

    OpenAIRE

    Heri Retnawati

    2017-01-01

    The study was to identify the load, the type and the significance of differential item functioning (DIF) in constructed response item using the partial credit model (PCM). The data in the study were the students’ instruments and the students’ responses toward the PISA-like test items that had been completed by 386 ninth grade students and 460 tenth grade students who had been about 15 years old in the Province of Yogyakarta Special Region in Indonesia. The analysis toward the item characteris...

  18. Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals.

    Science.gov (United States)

    Kim, H C; Kim, H J; Lee, C J; Kim, B M; Park, J K; Versluis, A

    2009-07-01

    To evaluate how different cross-sectional designs affect stress distribution in nickel-titanium (NiTi) instruments during bending, torsion and simulated shaping of a curved canal. Four NiTi rotary instruments with different cross-sectional geometries were selected: ProFile and HeroShaper systems with a common triangle-based cross section, Mtwo with an S-shaped rectangle-based design and NRT with a modified rectangle-based design. The geometries of the selected files were scanned in a micro-CT and three-dimensional finite-element models were created for each system. Stiffness characteristics for each file system were determined in a series of bending and torsional conditions. Canal shaping was simulated by inserting models of the rotating file into a 45 degrees curved canal model. Stress distribution in the instruments was recorded during simulated shaping. After the instruments were retracted from the canal, residual stresses and permanent bending of their tips due to plastic deformation were determined. The greatest bending and torsional stiffness occurred in the NRT file. During simulated shaping, the instruments with triangle-based cross-sectional geometry had more even stress distributions along their length and had lower stress concentrations than the instruments with rectangle-based cross sections. Higher residual stresses and plastic deformations were found in the Mtwo and NRT with rectangle-based cross-sectional geometries. Nickel-titanium instruments with rectangle-based cross-sectional designs created higher stress differentials during simulated canal shaping and may encounter higher residual stress and plastic deformation than instruments with triangle-based cross sections.

  19. Frequency response function (FRF) based updating of a laser spot welded structure

    Science.gov (United States)

    Zin, M. S. Mohd; Rani, M. N. Abdul; Yunus, M. A.; Sani, M. S. M.; Wan Iskandar Mirza, W. I. I.; Mat Isa, A. A.

    2018-04-01

    The objective of this paper is to present frequency response function (FRF) based updating as a method for matching the finite element (FE) model of a laser spot welded structure with a physical test structure. The FE model of the welded structure was developed using CQUAD4 and CWELD element connectors, and NASTRAN was used to calculate the natural frequencies, mode shapes and FRF. Minimization of the discrepancies between the finite element and experimental FRFs was carried out using the exceptional numerical capability of NASTRAN Sol 200. The experimental work was performed under free-free boundary conditions using LMS SCADAS. Avast improvement in the finite element FRF was achieved using the frequency response function (FRF) based updating with two different objective functions proposed.

  20. Lung function and bronchial responsiveness after Mycoplasma pneumoniae infection in early childhood

    DEFF Research Database (Denmark)

    Boysen, Birgitte Kjær; Jensen, Jørgen S; Nielsen, Kim G

    2008-01-01

    by whole-body plethysmography and bronchial hyperresponsiveness was assessed by cold, dry air hyperventilation. Neither baseline lung function nor bronchial response to cold dry air hyperventilation differed between M. pneumoniae-positive and -negative children: mean baseline lung function were 1.17 versus...

  1. Catecholamine Responses to Virtual Combat: Implications for Post-Traumatic Stress and Dimensions of Functioning

    Directory of Open Access Journals (Sweden)

    Krista Beth Highland

    2015-03-01

    Full Text Available PTSD symptoms can result in functional impairment among service members (SMs, even in those without a clinical diagnosis. The variability in outcomes may be related to underlying catecholamine mechanisms. Individuals with PTSD tend to have elevated basal catecholamine levels, though less is known regarding catecholamine responses to trauma-related stimuli. We assessed whether catecholamine responses to a virtual combat environment impact the relationship between PTSD symptom clusters and elements of functioning. Eighty-seven clinically healthy SMs, within 2 months after deployment to Iraq or Afghanistan, completed self-report measures, viewed virtual-reality (VR combat sequences, and had sequential blood draws. Norepinephrine responses to VR combat exposure moderated the relationship between avoidance symptoms and scales of functioning including physical functioning, physical-role functioning, and vitality. Among those with high levels of avoidance, norepinephrine change was inversely associated with functional status, whereas a positive correlation was observed for those with low levels of avoidance. Our findings represent a novel use of a virtual environment to display combat-related stimuli to returning SMs to elucidate mind-body connections inherent in their responses. The insight gained improves our understanding of post-deployment symptoms and quality of life in SMs and may facilitate enhancements in treatment. Further research is needed to validate these findings in other populations and to define the implications for treatment effectiveness.

  2. Impact of sound production by wind instruments on the temporomandibular system of male instrumentalists.

    Science.gov (United States)

    Pampel, Michael; Jakstat, Holger A; Ahlers, Oliver M

    2014-01-01

    Playing a wind instrument can be either a reason for overuse or a protecting factor against certain diseases. Some individuals have many findings but low morbidity while others have few findings but high morbidity. This contradictory phenomenon should be researched. The temporomandibular system (TMS) is a functional unit which comprises the mandible, associated muscles and bilateral joints with the temporal bone. The TMS is responsible for the generation of sound when wind instruments are played. Over the long-term and with intensive usage, this causes changes in the musculature and in the temporomandibular joint (TMJ) of wind musicians, often resulting in temporomandibular disorders (TMD). The aim of this study is to examine evidence that TMD constitute an occupational disease in wind musicians. TMD patients and wind musicians were examined by dental clinical functional analysis. 102 male subjects were divided into three groups: "healthy" individuals, wind musicians, and patients with TMD. Dental Examination was carried out based on focused inclusion of the research diagnostic criteria - TMD [1,7]. Findings were evaluated for statistical significance by first transferring data into a digital database [2,15], then generating T-Test und Wilcoxon-Test when non-Gaussian distribution appears and applying the Mann-Whitney rank sum test using Sigmaplot Version 1.1 software (Systat Software Inc, Washington, USA). The evaluation revealed that wind instrument musicians show a high incidence of developing TMD as the researchers found almost 100% morbidity regarding parafunctional habits and preauricular muscle pain of each adult and highly active musician. The result is highly significant (pTMS.

  3. Executing application function calls in response to an interrupt

    Science.gov (United States)

    Almasi, Gheorghe; Archer, Charles J.; Giampapa, Mark E.; Gooding, Thomas M.; Heidelberger, Philip; Parker, Jeffrey J.

    2010-05-11

    Executing application function calls in response to an interrupt including creating a thread; receiving an interrupt having an interrupt type; determining whether a value of a semaphore represents that interrupts are disabled; if the value of the semaphore represents that interrupts are not disabled: calling, by the thread, one or more preconfigured functions in dependence upon the interrupt type of the interrupt; yielding the thread; and if the value of the semaphore represents that interrupts are disabled: setting the value of the semaphore to represent to a kernel that interrupts are hard-disabled; and hard-disabling interrupts at the kernel.

  4. Instrumental interaction

    OpenAIRE

    Luciani , Annie

    2007-01-01

    International audience; The expression instrumental interaction as been introduced by Claude Cadoz to identify a human-object interaction during which a human manipulates a physical object - an instrument - in order to perform a manual task. Classical examples of instrumental interaction are all the professional manual tasks: playing violin, cutting fabrics by hand, moulding a paste, etc.... Instrumental interaction differs from other types of interaction (called symbolic or iconic interactio...

  5. ASPECT OF LANGUAGE ON A QUALITATIVE ANALYSIS OF STUDENT’S EVALUATION INSTRUMENT

    Directory of Open Access Journals (Sweden)

    Ismanto Ismanto

    2016-11-01

    Full Text Available This article examined the characteristics of good student’s evaluation instrument. There are at least two requirements that must be met. Those are valid and reliable. The validity of the instrument can be seen from the instrument's ability to measure what should be measured. The fact the existence of the validity of an instrument may be a grain fill, the response process, internal structure, relationship with other variables, and the consequences of the implementation of the charging instrument. Analysis of the content is then known as content validity, i.e. rational analysis of the domain to be measured to determine the representation of each item on the instrument with the ability to be measured. Content validity is submitting pieces of blue print and items of the instrument to the experts to be analyzed quantitatively and qualitatively.

  6. Bayesian nonparametric estimation of continuous monotone functions with applications to dose-response analysis.

    Science.gov (United States)

    Bornkamp, Björn; Ickstadt, Katja

    2009-03-01

    In this article, we consider monotone nonparametric regression in a Bayesian framework. The monotone function is modeled as a mixture of shifted and scaled parametric probability distribution functions, and a general random probability measure is assumed as the prior for the mixing distribution. We investigate the choice of the underlying parametric distribution function and find that the two-sided power distribution function is well suited both from a computational and mathematical point of view. The model is motivated by traditional nonlinear models for dose-response analysis, and provides possibilities to elicitate informative prior distributions on different aspects of the curve. The method is compared with other recent approaches to monotone nonparametric regression in a simulation study and is illustrated on a data set from dose-response analysis.

  7. Response function study of a scintillator detector of NaI(Tl)

    International Nuclear Information System (INIS)

    Villa, Marcelo Barros; Costa, Alessandro Martins da

    2014-01-01

    In measurements of gamma rays with Nai (Tl) scintillator, the detectors output data are pulse height spectra, that corresponding to distorted information about the radiation source due to various errors associated with the crystal scintillation process and electronics associated, instead of power spectra photons. Pulse height spectra are related to the real power spectra by means of scintillator detector response function NaI (Tl). In this work, the response function for a cylindrical crystal of Nal (Tl) of 7,62 x 7,62 cm (diameter x length) was studied, by Monte Carlo method, using the EGSnrc tool to model the transport of radiation, combined with experimental measurements. An inverse response matrix, even with the energy of the square root, which transforms the pulse height spectrum of photon energy spectrum was obtained. The results of this transformation of pulse height spectrum for photon energy spectrum is presented, showing that the methodology employed in this study is suitable

  8. Instrumentation and Controls Division progress report for the period July 1, 1986 to June 30, 1988

    International Nuclear Information System (INIS)

    Klobe, L.E.

    1988-12-01

    The Instrumentation and Controls (IandC) Division of Oak Ridge National Laboratory (ORNL) performs basic and applied instrumentation and controls research, development and design engineering, specialized instrument design and fabrication, and maintenance services for instruments, electronics, and computers. The IandC Division is one of the largest RandD organizations of its type among government laboratories, and it exists as the result of an organizational strategy to integrate ORNL's instrumentation and controls-related disciplines into one dedicated functional organization to increase the Laboratory's expertise and capabilities in these rapidly expanding, innovative areas of technology. The Division participates in the programs and projects of ORNL by applying its expertise and capabilities in concert with other divisions to perform basic research and mission-oriented technology development. Many of the Division's RandD tasks that are a part of a larger ORNL program are of sufficient scope that the IandC effort constitutes a separate program element with direct funding and management responsibility within the Division. The activities of IandC include performance of an RandD task in IandC facilities, the participation of from one of many IandC engineers and scientists in a multidisciplinary team working in a specific research area or development project, design and fabrication of a special instrument or instrumentation system, or a few hours of maintenance service. In its support and maintenance work, the role of the IandC Division is to provide a level of expertise appropriate to complete a job successfully at minimum overall cost and time schedule---a role which involves IandC in almost all ORNL activities

  9. Instrumentation and Controls Division progress report for the period July 1, 1986 to June 30, 1988

    Energy Technology Data Exchange (ETDEWEB)

    Klobe, L.E. (ed.)

    1988-12-01

    The Instrumentation and Controls (IandC) Division of Oak Ridge National Laboratory (ORNL) performs basic and applied instrumentation and controls research, development and design engineering, specialized instrument design and fabrication, and maintenance services for instruments, electronics, and computers. The IandC Division is one of the largest RandD organizations of its type among government laboratories, and it exists as the result of an organizational strategy to integrate ORNL's instrumentation and controls-related disciplines into one dedicated functional organization to increase the Laboratory's expertise and capabilities in these rapidly expanding, innovative areas of technology. The Division participates in the programs and projects of ORNL by applying its expertise and capabilities in concert with other divisions to perform basic research and mission-oriented technology development. Many of the Division's RandD tasks that are a part of a larger ORNL program are of sufficient scope that the IandC effort constitutes a separate program element with direct funding and management responsibility within the Division. The activities of IandC include performance of an RandD task in IandC facilities, the participation of from one of many IandC engineers and scientists in a multidisciplinary team working in a specific research area or development project, design and fabrication of a special instrument or instrumentation system, or a few hours of maintenance service. In its support and maintenance work, the role of the IandC Division is to provide a level of expertise appropriate to complete a job successfully at minimum overall cost and time schedule---a role which involves IandC in almost all ORNL activities.

  10. How linear features alter predator movement and the functional response.

    KAUST Repository

    McKenzie, Hannah W

    2012-01-18

    In areas of oil and gas exploration, seismic lines have been reported to alter the movement patterns of wolves (Canis lupus). We developed a mechanistic first passage time model, based on an anisotropic elliptic partial differential equation, and used this to explore how wolf movement responses to seismic lines influence the encounter rate of the wolves with their prey. The model was parametrized using 5 min GPS location data. These data showed that wolves travelled faster on seismic lines and had a higher probability of staying on a seismic line once they were on it. We simulated wolf movement on a range of seismic line densities and drew implications for the rate of predator-prey interactions as described by the functional response. The functional response exhibited a more than linear increase with respect to prey density (type III) as well as interactions with seismic line density. Encounter rates were significantly higher in landscapes with high seismic line density and were most pronounced at low prey densities. This suggests that prey at low population densities are at higher risk in environments with a high seismic line density unless they learn to avoid them.

  11. How linear features alter predator movement and the functional response.

    KAUST Repository

    McKenzie, Hannah W; Merrill, Evelyn H; Spiteri, Raymond J; Lewis, Mark A

    2012-01-01

    In areas of oil and gas exploration, seismic lines have been reported to alter the movement patterns of wolves (Canis lupus). We developed a mechanistic first passage time model, based on an anisotropic elliptic partial differential equation, and used this to explore how wolf movement responses to seismic lines influence the encounter rate of the wolves with their prey. The model was parametrized using 5 min GPS location data. These data showed that wolves travelled faster on seismic lines and had a higher probability of staying on a seismic line once they were on it. We simulated wolf movement on a range of seismic line densities and drew implications for the rate of predator-prey interactions as described by the functional response. The functional response exhibited a more than linear increase with respect to prey density (type III) as well as interactions with seismic line density. Encounter rates were significantly higher in landscapes with high seismic line density and were most pronounced at low prey densities. This suggests that prey at low population densities are at higher risk in environments with a high seismic line density unless they learn to avoid them.

  12. Instrumentation development

    International Nuclear Information System (INIS)

    Ubbes, W.F.; Yow, J.L. Jr.

    1988-01-01

    Instrumentation is developed for the Civilian Radioactive Waste Management Program to meet several different (and sometimes conflicting) objectives. This paper addresses instrumentation development for data needs that are related either directly or indirectly to a repository site, but does not touch on instrumentation for work with waste forms or other materials. Consequently, this implies a relatively large scale for the measurements, and an in situ setting for instrument performance. In this context, instruments are needed for site characterization to define phenomena, develop models, and obtain parameter values, and for later design and performance confirmation testing in the constructed repository. The former set of applications is more immediate, and is driven by the needs of program design and performance assessment activities. A host of general technical and nontechnical issues have arisen to challenge instrumentation development. Instruments can be classed into geomechanical, geohydrologic, or other specialty categories, but these issues cut across artificial classifications. These issues are outlined. Despite this imposing list of issues, several case histories are cited to evaluate progress in the area

  13. Mobile Instruments Measure Atmospheric Pollutants

    Science.gov (United States)

    2009-01-01

    As a part of NASA's active research of the Earth s atmosphere, which has included missions such as the Atmospheric Laboratory of Applications and Science (ATLAS, launched in 1992) and the Total Ozone Mapping Spectrometer (TOMS, launched on the Earth Probe satellite in 1996), the Agency also performs ground-based air pollution research. The ability to measure trace amounts of airborne pollutants precisely and quickly is important for determining natural patterns and human effects on global warming and air pollution, but until recent advances in field-grade spectroscopic instrumentation, this rapid, accurate data collection was limited and extremely difficult. In order to understand causes of climate change and airborne pollution, NASA has supported the development of compact, low power, rapid response instruments operating in the mid-infrared "molecular fingerprint" portion of the electromagnetic spectrum. These instruments, which measure atmospheric trace gases and airborne particles, can be deployed in mobile laboratories - customized ground vehicles, typically - to map distributions of pollutants in real time. The instruments must be rugged enough to operate rapidly and accurately, despite frequent jostling that can misalign, damage, or disconnect sensitive components. By measuring quickly while moving through an environment, a mobile laboratory can correlate data and geographic points, revealing patterns in the environment s pollutants. Rapid pollutant measurements also enable direct determination of pollutant sources and sinks (mechanisms that remove greenhouse gases and pollutants), providing information critical to understanding and managing atmospheric greenhouse gas and air pollutant concentrations.

  14. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  15. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  16. Estimation of the pseudoacceleration response spectra in sites of Mexico

    International Nuclear Information System (INIS)

    Jara-Guerrero, J. M.; Jara-Diaz, M.; Hernandez, H.

    2007-01-01

    A methodology for the pseudoacceleration response spectra assessment using utility functions is presented. This methodology was applied to the seismic hazard analysis of several cities in Mexico. After the identification of the main seismic sources that could affect the site, attenuation laws are proposed using empirical models and the instrumental information collected. Historical seismicity data and recent seismic data obtained form the strong-motion networks installed on several sites of the country are used for evaluating the characteristics of the coastal earthquakes. Due to the lack of instrumental information, empirical data are employed in other seismic faults. Source parameters, characterized by the maximum magnitudes expected, are chosen according to the physical parameters of the faults and a Bayesian analysis approach. The subduction earthquake occurrences are established with a relation between the time since the last major event and the expected magnitude of the next one. Bayes theorem was applied twice to determine the probability distribution of the parameters in the lognormal distribution of the interoccurrence times for each of the Mexican subduction segments. Annual exceedence rates of the ground acceleration and pseudoacceleration response spectra parameters based on a utility function are obtained. (authors)

  17. Towards an Analogue Neuromorphic VLSI Instrument for the Sensing of Complex Odours

    Science.gov (United States)

    Ab Aziz, Muhammad Fazli; Harun, Fauzan Khairi Che; Covington, James A.; Gardner, Julian W.

    2011-09-01

    Almost all electronic nose instruments reported today employ pattern recognition algorithms written in software and run on digital processors, e.g. micro-processors, microcontrollers or FPGAs. Conversely, in this paper we describe the analogue VLSI implementation of an electronic nose through the design of a neuromorphic olfactory chip. The modelling, design and fabrication of the chip have already been reported. Here a smart interface has been designed and characterised for thisneuromorphic chip. Thus we can demonstrate the functionality of the a VLSI neuromorphic chip, producing differing principal neuron firing patterns to real sensor response data. Further work is directed towards integrating 9 separate neuromorphic chips to create a large neuronal network to solve more complex olfactory problems.

  18. RICE: A Reliable and Efficient Remote Instrumentation Collaboration Environment

    Directory of Open Access Journals (Sweden)

    Prasad Calyam

    2008-01-01

    Full Text Available Remote access of scientific instruments over the Internet (i.e., remote instrumentation demand high-resolution (2D and 3D video image transfers with simultaneous real-time mouse and keyboard controls. Consequently, user quality of experience (QoE is highly sensitive to network bottlenecks. Further, improper user control while reacting to impaired video caused due to network bottlenecks could result in physical damages to the expensive instrument equipment. Hence, it is vital to understand the interplay between (a user keyboard/mouse actions toward the instrument, and (b corresponding network reactions for transfer of instrument video images toward the user. In this paper, we first present an analytical model for characterizing user and network interplay during remote instrumentation sessions in terms of demand and supply interplay principles of traditional economics. Next, we describe the trends of the model parameters using subjective and objective measurements obtained from QoE experiments. Thereafter, we describe our Remote Instrumentation Collaboration Environment (RICE software that leverages our experiences from the user and network interplay studies, and has functionalities that facilitate reliable and efficient remote instrumentation such as (a network health awareness to detect network bottleneck periods, and (b collaboration tools for multiple participants to interact during research and training sessions.

  19. Emergence of ratio-dependent and predator-dependent functional responses for pollination mutualism and seed parasitism

    Science.gov (United States)

    DeAngelis, Donald L.; Holland, J. Nathaniel

    2006-01-01

    Prey (N) dependence [g(N)], predator (P) dependence [g(P) or g(N,P)], and ratio dependence [f(P/N)] are often seen as contrasting forms of the predator's functional response describing predator consumption rates on prey resources in predator–prey and parasitoid–host interactions. Analogously, prey-, predator-, and ratio-dependent functional responses are apparently alternative functional responses for other types of consumer–resource interactions. These include, for example, the fraction of flowers pollinated or seeds parasitized in pollination (pre-dispersal) seed-parasitism mutualisms, such as those between fig wasps and fig trees or yucca moths and yucca plants. Here we examine the appropriate functional responses for how the fraction of flowers pollinated and seeds parasitized vary with the density of pollinators (predator dependence) or the ratio of pollinator and flower densities (ratio dependence). We show that both types of functional responses can emerge from minor, but biologically important variations on a single model. An individual-based model was first used to describe plant–pollinator interactions. Conditional upon on whether the number of flowers visited by the pollinator was limited by factors other than search time (e.g., by the number of eggs it had to lay, if it was also a seed parasite), and on whether the pollinator could directly find flowers on a plant, or had to search, the simulation results lead to either a predator-dependent or a ratio-dependent functional response. An analytic model was then used to show mathematically how these two cases can arise.

  20. The Gem Infrasound Logger and Custom-Built Instrumentation

    International Nuclear Information System (INIS)

    Anderson, Jacob F.; Ronan, Timothy J.

    2017-01-01

    Here, we designed, built, and recorded data with a custom infrasound logger (referred to as the Gem) that is inexpensive, portable, and easy to use. We also describe its design process, qualities, and applications in this article. Field instrumentation is a key element of geophysical data collection, and the quantity and quality of data that can be recorded is determined largely by the characteristics of the instruments used. Geophysicists tend to rely on commercially available instruments, which suffice for many important types of fieldwork. However, commercial instrumentation can fall short in certain roles, which motivates the development of custom sensors and data loggers. Particularly, we found existing data loggers to be expensive and inconvenient for infrasound campaigns, and developed the Gem infrasound logger in response. In this article, we discuss development of this infrasound logger and the various uses found for it, including projects on volcanoes, high-altitude balloons, and rivers. Further, we demonstrate that when needed, scientists can feasibly design and build their own specialized instruments, and that doing so can enable them to record more and better data at a lower cost.

  1. Development and evaluation of fixed phrase registration function for disaster response management system

    International Nuclear Information System (INIS)

    Suzuki, Takeyasu; Tsuda, Teppei

    2012-01-01

    It is important that three elements such as what happened, how it will advance, and how people should act are intelligibly transferred in disaster information from administrative organs to local residents. In this paper, authors developed the fixed phrase registration function and it was implemented in disaster response management system authors have previously developed. The system was applied to disaster response exercise in Mitsuke City, Niigata prefecture and the function was highly evaluated by employees of Mitsuke City. (author)

  2. Instrument calls and real-time code for laboratory automation

    International Nuclear Information System (INIS)

    Taber, L.; Ames, H.S.; Yamauchi, R.K.; Barton, G.W. Jr.

    1978-01-01

    These programs are the result of a joint Lawrence Livermore Laboratory and Environmental Protection Agency project to automate water quality laboratories. They form the interface between the analytical instruments and the BASIC language programs for data reduction and analysis. They operate on Data General NOVA 840's at Cincinnati and Chicago and on a Data General ECLIPSE C330 at Livermore. The operating system consists of unmodified RDOS, Data General's disk operating system, and Data General's multiuser BASIC modified to provide the instrument CALLs and other functions described. Instruments automated at various laboratories include Technicon AutoAnalyzers, atomic absorption spectrophotometers, total organic carbon analyzers, an emission spectrometer, an electronic balance, sample changers, and an optical spectrophotometer. Other instruments may be automated using these same CALLs, or new CALLs may be written as described

  3. A Comparison of the McMaster and Circumplex Family Assessment Instruments.

    Science.gov (United States)

    Fristad, Mary A.

    1989-01-01

    Compared clinical rating scales and self-report scales from McMaster and Circumplex models of family functioning with families (N=41). Found McMaster instruments had superior sensitivity; greater correspondence between clinical rating scales and family member self-report inventories on McMaster instruments; and lack of support for the curvilinear…

  4. The Effects of Training on Recognition of Musical Instruments by Adults with Cochlear Implants.

    Science.gov (United States)

    Driscoll, Virginia D

    2012-11-01

    This study examines the efficiency and effectiveness of three types of training on recognition of musical instruments by adults with cochlear implants (CI). Seventy-one adults with CIs were randomly assigned to one of three training conditions: feedback on response accuracy, feedback-plus (response accuracy plus correct answer), and direct instruction. Each participant completed three training sessions per week over a five-week time period in which they listened to recorded excerpts of eight different musical instruments. Results showed significant pre-to-posttest improvement in music instrument recognition accuracy for all three training conditions (22.9-25.7%, p types of auditory rehabilitation for persons who use CIs.

  5. Clinical utility of an automated instrument for gram staining single slides.

    Science.gov (United States)

    Baron, Ellen Jo; Mix, Samantha; Moradi, Wais

    2010-06-01

    Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis.

  6. Analyzing the Stability of Price Response Functions: Measuring the Influence of Different Parameters in a Monte Carlo Comparison

    Science.gov (United States)

    Brusch, Michael; Baier, Daniel

    The usage and the estimation of price response function is very important for strategic marketing decisions. Typically price response functions with an empirical basis are used. However, such price response functions are subject to a lot of disturbing influence factors, e.g., the assumed profit maximum price and the assumed corresponding quantity of sales. In such cases, the question how stable the found price response function is was not answered sufficiently up to now. In this paper, the question will be pursued how much (and what kind of) errors in market research are pardonable for a stable price response function. For the comparisons, a factorial design with synthetically generated and disturbed data is used.

  7. Planck 2015 results: VII. High Frequency Instrument data processing: Time-ordered information and beams

    International Nuclear Information System (INIS)

    Adam, R.; Ade, P. A. R.; Aghanim, N.; Arnaud, M.; Ashdown, M.

    2016-01-01

    The Planck High Frequency Instrument (HFI) has observed the full sky at six frequencies (100, 143, 217, 353, 545, and 857 GHz) in intensity and at four frequencies in linear polarization (100, 143, 217, and 353 GHz). In order to obtain sky maps, the time-ordered information (TOI) containing the detector and pointing samples must be processed and the angular response must be assessed. The full mission TOI is included in the Planck 2015 release. This study describes the HFI TOI and beam processing for the 2015 release. HFI calibration and map making are described in a companion paper. The main pipeline has been modified since the last release (2013 nominal mission in intensity only), by including a correction for the nonlinearity of the warm readout and by improving the model of the bolometer time response. The beam processing is an essential tool that derives the angular response used in all the Planck science papers and we report an improvement in the effective beam window function uncertainty of more than a factor of 10 relative to the2013 release. Noise correlations introduced by pipeline filtering function are assessed using dedicated simulations. Finally, angular cross-power spectra using data sets that are decorrelated in time are immune to the main systematic effects.

  8. Medical instruments and devices principles and practices

    CERN Document Server

    Schreiner, Steven; Peterson, Donald R

    2015-01-01

    Medical Instruments and Devices: Principles and Practices originates from the medical instruments and devices section of The Biomedical Engineering Handbook, Fourth Edition. Top experts in the field provide material that spans this wide field. The text examines how biopotential amplifiers help regulate the quality and content of measured signals. It includes instruments and devices that span a range of physiological systems and the physiological scale: molecular, cellular, organ, and system. The book chronicles the evolution of pacemakers and their system operation and discusses oscillometry, cardiac output measurement, and the direct and indirect methods of measuring cardiac output. The authors also expound on the mechanics and safety of defibrillators and cover implantable stimulators, respiration, and the structure and function of mechanical ventilators. In addition, this text covers in depth: Anesthesia Delivery Electrosurgical Units and Devices Biomedical Lasers Measuring Cellular Traction Forces Blood G...

  9. Determination of the Integral/SPI instrumental response and his application to the observation of gamma ray lines in the Vela region

    International Nuclear Information System (INIS)

    Attie, D.

    2005-01-01

    The INTEGRAL/SPI spectrometer was designed to observe the sky in the energy band of 20 keV to 8 MeV. The specificity of instrument SPI rests on the excellent spectral resolution (2.3 keV with 1 MeV) of its detecting plan, composed of 19 cooled germanium crystals; covering an effective area of 508 cm 2 . The use of a coded mask, located at 1.7 m above the detection plan ensures to it a resolving power of 2.5 degrees. The aim of this thesis, begun before the INTEGRAL launch, is made up of two parts. The first part relates to the analysis of the spectrometer calibration data. The objective was to measure and check the performances of the telescope, in particular to validate simulations of the INTEGRAL/SPI instrument response. This objective was successfully achieved. This analysis also highlights the presence of a significant instrumental background noise. Whereas, the second part concentrates on the data analysis of the Vela region observations. I have approached two astrophysical topics dealing with: - the search for radioactive decays lines of titanium-44, which is produced by explosive nucleosynthesis, in the supernova remnant of Vela Junior and, - the search of cyclotron resonance scattering features expected towards 25 keV and 52 keV in the accreting pulsar spectrum of the x-ray binary star Vela X-1. Putting forward the hypothesis that the result obtained previously by COMPTEL is correct and considering the no-detection of the titanium-44 lines by SPI, we give a lower limit at 4500 km s -1 for the ejecta velocity from Vela Junior. The analysis on the research of the cyclotron lines have shown that the results are very sensitive to the instrumental background. Thorough studies will be necessary to guarantee an unambiguous detection of these lines. (author)

  10. Vision though afocal instruments: generalized magnification and eye-instrument interaction

    Science.gov (United States)

    Harris, William F.; Evans, Tanya

    2018-04-01

    In Gaussian optics all observers experience the same magnification, the instrument's angular magnification, when viewing distant objects though a telescope or other afocal instruments. However, analysis in linear optics shows that this is not necessarily so in the presence of astigmatism. Because astigmatism may distort and rotate images it is appropriate to work with generalized angular magnification represented by a 2 × 2 matrix. An expression is derived for the generalized magnification for an arbitrary eye looking through an arbitrary afocal instrument. With afocal instruments containing astigmatic refracting elements not all eyes experience the same generalized magnification; there is interaction between eye and instrument. Eye-instrument interaction may change as the instrument is rotated about its longitudinal axis, there being no interaction in particular orientations. A simple numerical example is given. For sake of completeness, expressions for generalized magnification are also presented in the case of instruments that are not afocal and objects that are not distant.

  11. 49 CFR 572.200 - Instrumentation and test conditions.

    Science.gov (United States)

    2010-10-01

    ... TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES IIsD... Test, unless noted otherwise. (g) All instrumented response signal measurements shall be treated to the... conform to the Sign Convention For Vehicle Crash Testing, Surface Vehicle Information Report, SAE J1733...

  12. Development of ultrasonic instrument 'UT1000 Series'

    International Nuclear Information System (INIS)

    Ogura, Yukio; Ikeda, Toshimichi

    1984-01-01

    The ultrasonic flaw detectors with 'A-scope indication' have been frequently used as the means for confirming the soundness of structures and equipments, but there are problems in their operational, quantifying and recording capabilities. Recently, the digital ultrasonic measuring instrument of touch panel type ''UT 1000 Series'' has been developed, which resolves these problems by a single effort. This measuring instrument is that of portable type, which gives the digital output of measured results in real time only by lightly touching the peak point of an echo on the Brown tube. This instrument contains the rich software for measurement, and can measure the positions and dimensions of defects and the pressure on contact surfaces with high accuracy. 'A-scope indication' is the indication with an oscilloscope taking the intensity of echo and the propagation time of ultrasonic waves on the ordinate and abscissa, respectively. There are three types of the instrument, that is, for detecting defects, for measuring contact surface pressure and for both purposes. The size of the instrument is 240 mm width, 350 mm length and 175 mm height, and the weight is 8.5 kgf. The specification, function and features of the ultrasonic flaw detector, touch panel, gain setter, key board, microcomputer and others are reported. (Kako, I.)

  13. The digital reactor protection system for the instrumentation and control of reactor TRIGA PUSPATI (RTP)

    International Nuclear Information System (INIS)

    Nurfarhana Ayuni Joha; Izhar Abu Hussin; Mohd Idris Taib; Zareen Khan Abdul Jalil Khan

    2010-01-01

    Reactor Protection System (RPS) is important for Reactor Instrumentation and Control System. The RPS comprises all redundant electrical devices and circuitry involved in the generation of those initiating signals associated to the trip protective function. The instrumentation system for the RPS provides automatic protection signals against unsafe and improper reactor operation. The physical separation is provided for all of the redundant instrumentation systems to preserve redundancy. The safety protection systems using circuits composed of analog instruments and relays with relay contacts is difficult to realize from various reasons. Therefore, an application of digital technology can be said a logical conclusion also in the light of its functional superiority. (author)

  14. Intake rates and the functional response in shorebirds (Charadriiformes) eating macro-invertebrates

    NARCIS (Netherlands)

    Goss-Custard, John D.; West, Andrew D.; Yates, Michael G.; Caldow, Richard W. G.; Stillman, Richard A.; Bardsley, Louise; Castilla, Juan; Castro, Macarena; Dierschke, Volker; Durell, Sarah E. A. Le V. Dit; Eichhorn, Goetz; Ens, Bruno J.; Exo, Klaus-Michael; Udayangani-Fernando, P. U.; Ferns, Peter N.; Hockey, Philip A. R.; Gill, Jennifer A.; Johnstone, Ian; Kalejta-Summers, Bozena; Masero, Jose A.; Moreira, Francisco; Nagarajan, Rajarathina Velu; Owens, Ian P. F.; Pacheco, Cristian; Perez-Hurtado, Alejandro; Rogers, Danny; Scheiffarth, Gregor; Sitters, Humphrey; Sutherland, William J.; Triplet, Patrick; Worrall, Dave H.; Zharikov, Yuri; Zwarts, Leo; Pettifor, Richard A.

    2006-01-01

    As field determinations take much effort, it would be useful to be able to predict easily the coefficients describing the functional response of free-living predators, the function relating food intake rate to the abundance of food organisms in the environment. As a means easily to parameterise an

  15. Taxonomic and functional responses to fire and post-fire management of a Mediterranean hymenoptera community.

    Science.gov (United States)

    Mateos, Eduardo; Santos, Xavier; Pujade-Villar, Juli

    2011-11-01

    Fire is one of the commonest disturbances worldwide, transforming habitat structure and affecting ecosystem functioning. Understanding how species respond to such environmental disturbances is a major conservation goal that should be monitored using functionally and taxonomically diverse groups such as Hymenoptera. In this respect, we have analyzed the taxonomic and functional response to fire and post-fire management of a Hymenoptera community from a Mediterranean protected area. Thus, Hymenoptera were sampled at fifteen sites located in three burnt areas submitted to different post-fire practices, as well as at five sites located in peripheral unburnt pine forest. A total of 4882 specimens belonging to 33 families, which were classified into six feeding groups according to their dietary preferences, were collected. ANOVA and Redundancy Analyses showed a taxonomic and functional response to fire as all burnt areas had more Hymenoptera families, different community composition and higher numbers of parasitoids than the unburnt area. Taxonomic differences were also found between burnt areas in terms of the response of Hymenoptera to post-fire management. In general the number of parasitoids was positively correlated to the number of potential host arthropods. Parasitoids are recognized to be sensitive to habitat changes, thus highlighting their value for monitoring the functional responses of organisms to habitat disturbance. The taxonomic and functional responses of Hymenoptera suggest that some pine-forest fires can enhance habitat heterogeneity and arthropod diversity, hence increasing interspecific interactions such as those established by parasitoids and their hosts.

  16. Taxonomic and Functional Responses to Fire and Post-Fire Management of a Mediterranean Hymenoptera Community

    Science.gov (United States)

    Mateos, Eduardo; Santos, Xavier; Pujade-Villar, Juli

    2011-11-01

    Fire is one of the commonest disturbances worldwide, transforming habitat structure and affecting ecosystem functioning. Understanding how species respond to such environmental disturbances is a major conservation goal that should be monitored using functionally and taxonomically diverse groups such as Hymenoptera. In this respect, we have analyzed the taxonomic and functional response to fire and post-fire management of a Hymenoptera community from a Mediterranean protected area. Thus, Hymenoptera were sampled at fifteen sites located in three burnt areas submitted to different post-fire practices, as well as at five sites located in peripheral unburnt pine forest. A total of 4882 specimens belonging to 33 families, which were classified into six feeding groups according to their dietary preferences, were collected. ANOVA and Redundancy Analyses showed a taxonomic and functional response to fire as all burnt areas had more Hymenoptera families, different community composition and higher numbers of parasitoids than the unburnt area. Taxonomic differences were also found between burnt areas in terms of the response of Hymenoptera to post-fire management. In general the number of parasitoids was positively correlated to the number of potential host arthropods. Parasitoids are recognized to be sensitive to habitat changes, thus highlighting their value for monitoring the functional responses of organisms to habitat disturbance. The taxonomic and functional responses of Hymenoptera suggest that some pine-forest fires can enhance habitat heterogeneity and arthropod diversity, hence increasing interspecific interactions such as those established by parasitoids and their hosts.

  17. Extruded snacks from whole wheat supplemented with textured soy flour: Effect on instrumental and sensory textural characteristics.

    Science.gov (United States)

    Rodríguez-Vidal, Arturo; Martínez-Flores, Héctor Eduardo; González Jasso, Eva; Velázquez de la Cruz, Gonzalo; Ramírez-Jiménez, Aurea K; Morales-Sánchez, Eduardo

    2017-06-01

    The quality of extruded snacks can be affected not only by processing conditions, but also by some factors like the concentration and type of ingredients incorporated in their formulation and the working conditions used. Although the process conditions have been established with measurable textural properties, sensory qualities have not been correlated with these responses in expanded extruded snacks made with added functional ingredients. Therefore, in this study the effect of adding textured soy flour (TSF) and whole wheat flour (WWF) to refined wheat flour in the production of extruded snacks and expanded with hot air was evaluated. A response surface design using two levels with five central points was applied to obtain the best combinations of functional ingredients added, holding the parameters of the extrusion process and moisture of treatments. Some texture characteristics and sensory analysis were used as response variables, such as, hardness, fracturability, toughness, crispness, granularity, and chewiness. Likewise, the rate of expansion was evaluated. The results showed that the level of substitution of WWF, especially levels of 15%, had a significant effect on the hardness perceived by the panelist during sensory evaluation. The TSF at concentrations of ≥15%, favored the fracturability and crispness of the samples. It was found that the best expansion index was with the combination of 5% TSF and 15% WWF. Although a correlation between instrumental and sensory tests carried out on the extruded snacks expanded was not found. The physical characteristics of the extruded snacks such as expansion, hardness, and density are important parameters in terms of consumer acceptability of the final product as well as their functional properties. In other words, the appearance and texture are two of the most important attributes that can be seen in snack foods. In particular, the texture can be measured by intrinsic tests: objective (instrumental) and subjective

  18. Field measurements and interpretation of TMI-2 instrumentation: IC-10-dPT

    International Nuclear Information System (INIS)

    Jones, J.E.; Smith, J.T.; Mathis, M.V.

    1982-01-01

    This report describes the measurements and results of the Control Rod Drive Bypass Flow IC-10-dPT. This instrument consists of a Bailey Type BY Process Computer Transmitter connected to a readout module by approximately 500 feet of cable through a penetration junction and an instrument mounting junction. The status of this instrument is uncertain, but it was producing a reasonable output reading of zero flow which could indicate it had not failed. As a result, measurements on this instrument were designed to determine if it were properly functioning

  19. Calibration procedure for Slocum glider deployed optical instruments.

    Science.gov (United States)

    Cetinić, Ivona; Toro-Farmer, Gerardo; Ragan, Matthew; Oberg, Carl; Jones, Burton H

    2009-08-31

    Recent developments in the field of the autonomous underwater vehicles allow the wide usage of these platforms as part of scientific experiments, monitoring campaigns and more. The vehicles are often equipped with sensors measuring temperature, conductivity, chlorophyll a fluorescence (Chl a), colored dissolved organic matter (CDOM) fluorescence, phycoerithrin (PE) fluorescence and spectral volume scattering function at 117 degrees, providing users with high resolution, real time data. However, calibration of these instruments can be problematic. Most in situ calibrations are performed by deploying complementary instrument packages or water samplers in the proximity of the glider. Laboratory calibrations of the mounted sensors are difficult due to the placement of the instruments within the body of the vehicle. For the laboratory calibrations of the Slocum glider instruments we developed a small calibration chamber where we can perform precise calibrations of the optical instruments aboard our glider, as well as sensors from other deployment platforms. These procedures enable us to obtain pre- and post-deployment calibrations for optical fluorescence instruments, which may differ due to the biofouling and other physical damage that can occur during long-term glider deployments. We found that biofouling caused significant changes in the calibration scaling factors of fluorescent sensors, suggesting the need for consistent and repetitive calibrations for gliders as proposed in this paper.

  20. Instrumentation and control systems for CANDU-PHW nuclear power plants

    International Nuclear Information System (INIS)

    Lepp, R.M.; Watkins, L.M.

    1982-02-01

    The instrumentation and control of CANDU nuclear power plants takes advantage of modern electronics technology in the extensive computerization of important control and man-machine functions. A description of these functions as well as those of the four Special Safety Systems is provided

  1. New functions of the este system - new possibilities for emergency response

    International Nuclear Information System (INIS)

    Carny, P.

    2005-01-01

    The ESTE system (Emergency Source Term Evaluation) is support instrument for off-site emergency response and its main objective is to assist to the crisis staff: - to mitigate radiological consequences of significant releases; - to manage the protective measures; - to manage emergency monitoring. At national level the ESTE system are implemented at the Emergency Response Centre of the Czech Republic (SUJB) and Austrian versions are implemented at the Crisis Centre of the Austrian Republic (BMLFUW). ESTE system can now be utilized not only in close (40 km) vicinity of the point of the release (NPP), but radiological impacts are now calculated across the whole country or over the country border. Puff Trajectory Model (PTM) with the background of geographical information system (GIS) is included in este. Numerical weather prediction data (wind fields) predicted for the whole or the part of the country are online connected with este and utilized for the puffs movement simulation and impacts calculations. It means that not only meteorological data from the point of release (measured or predicted), but 'meteorological data wind field' predicted for larger region across the country are used by the este system. (author)

  2. Transforming Water: Social Influence Moderates Psychological, Physiological, and Functional Response to a Placebo Product.

    Science.gov (United States)

    Crum, Alia J; Phillips, Damon J; Goyer, J Parker; Akinola, Modupe; Higgins, E Tory

    2016-01-01

    This paper investigates how social influence can alter physiological, psychological, and functional responses to a placebo product and how such responses influence the ultimate endorsement of the product. Participants consumed a product, "AquaCharge Energy Water," falsely-labeled as containing 200 mg of caffeine but which was actually plain spring water, in one of three conditions: a no social influence condition, a disconfirming social influence condition, and a confirming social influence condition. Results demonstrated that the effect of the product labeling on physiological alertness (systolic blood pressure), psychological alertness (self-reported alertness), functional alertness (cognitive interference), and product endorsement was moderated by social influence: participants experienced more subjective, physiological and functional alertness and stronger product endorsement when they consumed the product in the confirming social influence condition than when they consumed the product in the disconfirming social influence condition. These results suggest that social influence can alter subjective, physiological, and functional responses to a faux product, in this case transforming the effects of plain water.

  3. On the responsibility concept and the agentive role of the instrument used for the action performance

    Directory of Open Access Journals (Sweden)

    Ivić Milka

    2002-01-01

    Full Text Available It is well established that the choice of subject depends on what the speaker estimates as most responsible for the successful occurrence of the action he is speaking of. The author enlightens the principles according to which in Serbian such a subject promotion may concern objects conceived as instruments indispensable for the performance of the transitive activity denoted by the sentence predicate verb. Pointing, however, to some Dutch language facts which make it quite evident that those principles are by no means universally valid, she claims that still more information about the whole problem are needed. She is, namely, convinced that such line of inquiry would not only enrich our present knowledge of micro parametric variations within the linguistic world, but could also be of relevant help to those researchers who expect, through observation of the facts of language, to get better insights into the ways the human brain works.

  4. The laval questionnaire: a new instrument to measure quality of life in morbid obesity.

    Science.gov (United States)

    Therrien, Fanny; Marceau, Picard; Turgeon, Nathalie; Biron, Simon; Richard, Denis; Lacasse, Yves

    2011-08-15

    Our recent review of the literature uncovered eleven obesity-specific quality of life questionnaires, all with incomplete demonstration of their measurement properties. Our objective was to validate a new self-administered questionnaire specific to morbid obesity to be used in clinical trials. The study was carried out at the bariatric surgery clinic of Laval Hospital, Quebec City, Canada. This study followed our description of health-related quality of life in morbid obesity from which we constructed the Laval Questionnaire. Its construct validity and responsiveness were tested by comparing the baseline and changes at 1-year follow-up in 6 domain scores (symptoms, activity/mobility, personal hygiene/clothing, emotions, social interactions, sexual life) with those of questionnaires measuring related constructs (SF-36, Impact of Weight on Quality of Life-Lite, Rosenberg Self-Esteem Scale and Beck Depression Inventory-II). 112 patients (67 who got bariatric surgery, 45 who remained on the waiting list during the study period) participated in this study. The analysis of the discriminative function of the questionnaire showed moderate-to-high correlations between the scores in each domain of our instrument and the corresponding questionnaires. The analysis of its evaluative function showed (1) significant differences in score changes between patients with bariatric surgery and those without, and (2) moderate-to-high correlations between the changes in scores in the new instrument and the changes in the corresponding questionnaires. Most of these correlations met the a priori predictions we had made regarding their direction and magnitude. The Laval Questionnaire is a valid measure of health-related quality of life in patients with morbid obesity and is responsive to treatment-induced changes.

  5. [Effect of a multifunctional instrument (HF scissors) in parotis surgery].

    Science.gov (United States)

    Strauss, G; Schaller, S; Gollnick, I

    2014-03-01

    Lateral parotidectomy is a demanding surgical procedure and requires a large number of instruments with a high frequency (HF) of alternating. Many functions, such as preparing, spreading, coagulating and cutting could be combined by using scissors with an integrated function of bipolar coagulation. This study has targeted an investigation of technical application, influence on surgery time, frequency of HF application and change of instruments. In the period between 01 April 2011 and 30 September 2012 (18 months) 35 procedures of lateral parotidectomy in 35 patients were investigated. In all cases lateral parotidectomy was carried out with a similar technique (modified extracapsular preparation). Workflow data were used from a control group in the period between 01 January 2009 and 31 December 2010 (24 months). The following parameters from both groups were documented and evaluated: incision-suture times (subdivided into nine sections of the procedure), change of instruments, period of application for HF function and early facial nerve function (6 h and 6 days after surgery according to House-Brackmann). Additionally, in the HF+ group a questionnaire that facilitated subjective evaluation of instruments was analyzed. It was possible to perform the surgery in both groups with neither technical nor surgical intraoperative complications. Incision-suture times showed an average reduction of 31.6 min (34.8 %) in the HF+ group. There was a reduction in the change of instruments compared to a conventional group (CONV) by up to 62.7 %. With the deployment of HF scissors there was a clear increase in the use of HF surgery by more than 100 % when comparing incision-suture times. Evaluation of both groups according to House-Brackmann showed a similar postoperative facial nerve function. The surgeons involved were of the opinion that in all 35 surgeries with HF scissors the intervention was easier and more comfortable. The use of HF scissors is appropriate for parotid gland

  6. Functionalized mesoporous silica nanoparticles for stimuli-responsive and targeted

    Energy Technology Data Exchange (ETDEWEB)

    Knezevic, Nikola [Iowa State Univ., Ames, IA (United States)

    2009-12-15

    Construction of functional supramolecular nanoassemblies has attracted great deal of attention in recent years for their wide spectrum of practical applications. Mesoporous silica nanoparticles (MSN) in particular were shown to be effective scaffolds for the construction of drug carriers, sensors and catalysts. Herein, we describe the synthesis and characterization of stimuli-responsive, controlled release MSN-based assemblies for drug delivery.

  7. Response inhibition is modulated by functional cerebral asymmetries for facial expression perception

    Directory of Open Access Journals (Sweden)

    Sebastian eOcklenburg

    2013-11-01

    Full Text Available The efficacy of executive functions is critically modulated by information processing in earlier cognitive stages. For example, initial processing of verbal stimuli in the language-dominant left-hemisphere leads to more efficient response inhibition than initial processing of verbal stimuli in the non-dominant right hemisphere. However, it is unclear whether this organizational principle is specific for the language system, or a general principle that also applies to other types of lateralized cognition. To answer this question, we investigated the neurophysiological correlates of early attentional processes, facial expression perception and response inhibition during tachistoscopic presentation of facial ‘Go’ and ‘Nogo’ stimuli in the left and the right visual field. Participants committed fewer false alarms after Nogo-stimulus presentation in the left compared to the right visual field. This right-hemispheric asymmetry on the behavioral level was also reflected in the neurophysiological correlates of face perception, specifically in a right-sided asymmetry in the N170 amplitude. Moreover, the right-hemispheric dominance for facial expression processing also affected event-related potentials typically related to response inhibition, namely the Nogo-N2 and Nogo-P3. These findings show that an effect of hemispheric asymmetries in early information processing on the efficacy of higher cognitive functions is not limited to left-hemispheric language functions, but can be generalized to predominantly right-hemispheric functions.

  8. The use of differential item functioning analyses to identify cultural differences in responses to the EORTC QLQ-C30

    NARCIS (Netherlands)

    Scott, N. W.; Fayers, P. M.; Aaronson, N. K.; Bottomley, A.; de Graeff, A.; Groenvold, M.; Koller, M.; Petersen, M. A.; Sprangers, M. A. G.

    2007-01-01

    INTRODUCTION: The European Organisation for Research and Treatment of Cancer (EORTC) QLQ-C30 is a widely used health-related quality of life instrument. The main aim of this study is to investigate whether there are international differences in response to the questionnaire that can be explained by

  9. Robotic, MEMS-based Multi Utility Sample Preparation Instrument for ISS Biological Workstation, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This project will develop a multi-functional, automated sample preparation instrument for biological wet-lab workstations on the ISS. The instrument is based on a...

  10. Comparison of reliability and responsiveness of patient-reported clinical outcome measures in knee osteoarthritis rehabilitation.

    Science.gov (United States)

    Williams, Valerie J; Piva, Sara R; Irrgang, James J; Crossley, Chad; Fitzgerald, G Kelley

    2012-08-01

    Secondary analysis, pretreatment-posttreatment observational study. To compare the reliability and responsiveness of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Knee Outcome Survey activities of daily living subscale (KOS-ADL), and the Lower Extremity Functional Scale (LEFS) in individuals with knee osteoarthritis (OA). The WOMAC is the current standard in patient-reported measures of function in patients with knee OA. The KOS-ADL and LEFS were designed for potential use in patients with knee OA. If the KOS-ADL and LEFS are to be considered viable alternatives to the WOMAC for measuring patient-reported function in individuals with knee OA, they should have measurement properties comparable to the WOMAC. It would also be important to determine whether either of these instruments may be superior to the WOMAC in terms of reliability or responsiveness in this population. Data from 168 subjects with knee OA, who participated in a rehabilitation program, were used in the analyses. Reliability and responsiveness of each outcome measure were estimated at follow-ups of 2, 6, and 12 months. Reliability was estimated by calculating the intraclass correlation coefficient (ICC2,1) for subjects who were unchanged in status from baseline at each follow-up time, based on a global rating of change score. To examine responsiveness, the standard error of the measurement, minimal detectable change, minimal clinically important difference, and the Guyatt responsiveness index were calculated for each outcome measure at each follow-up time. All 3 outcome measures demonstrated reasonable reliability and responsiveness to change. Reliability and responsiveness tended to decrease somewhat with increasing follow-up time. There were no substantial differences between outcome measures for reliability or any of the 3 measures of responsiveness at any follow-up time. The results do not indicate that one outcome measure is more reliable or responsive than

  11. Strategy for the development of EU Test Blanket Systems instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Calderoni, P., E-mail: Pattrick.Calderoni@f4e.europa.eu; Ricapito, I.; Poitevin, Y.

    2013-10-15

    Highlights: • We developed a strategy for the development of instrumentation for EU ITER TBSs. • TBSs instrumentation functions: safety, operation and scientific mission. • Described activities are in support of ITER design review process. -- Abstract: The instrumentation of the HCLL and HCPB Test Blanket System is fundamental in ensuring that ITER safety and operational requirements are satisfied as well as in enabling the scientific mission of the TBM program. It carries out three essential functions: (i) safety, intended as compliance with ITER requirements toward public and workers protection; (ii) system control, intended as compliance with ITER operational requirements and investment protection; and (iii) scientific mission, intended as validating technology and predictive tools for blanket concepts relevant to fusion energy systems. This paper describes the strategy for instrumentation development by providing details of the following five steps to be implemented in procured activities in the short to mid-term (3–4 years): (i) provide mapping of sensors requirements based on critical review of preliminary design data; (ii) develop functional specifications for TBS sensors based on the analysis of operative conditions in the various ITER buildings in which they are located; (iii) assess availability of commercial sensors against developed specifications; (iv) develop prototypes when no available solution is identified; and (v) perform single effect tests for the most critical solicitations and post-test examination of commercial products and prototypes. Examples of technology assessment in two technical areas are included to reinforce and complement the strategy description.

  12. A New Automated Instrument Calibration Facility at the Savannah River Site

    International Nuclear Information System (INIS)

    Polz, E.; Rushton, R.O.; Wilkie, W.H.; Hancock, R.C.

    1998-01-01

    The Health Physics Instrument Calibration Facility at the Savannah River Site in Aiken, SC was expressly designed and built to calibrate portable radiation survey instruments. The facility incorporates recent advances in automation technology, building layout and construction, and computer software to improve the calibration process. Nine new calibration systems automate instrument calibration and data collection. The building is laid out so that instruments are moved from one area to another in a logical, efficient manner. New software and hardware integrate all functions such as shipping/receiving, work flow, calibration, testing, and report generation. Benefits include a streamlined and integrated program, improved efficiency, reduced errors, and better accuracy

  13. Pancreatitis Quality of Life Instrument: Development of a new instrument

    Directory of Open Access Journals (Sweden)

    Wahid Wassef

    2014-02-01

    Full Text Available Objectives: The goal of this project was to develop the first disease-specific instrument for the evaluation of quality of life in chronic pancreatitis. Methods: Focus groups and interview sessions were conducted, with chronic pancreatitis patients, to identify items felt to impact quality of life which were subsequently formatted into a paper-and-pencil instrument. This instrument was used to conduct an online survey by an expert panel of pancreatologists to evaluate its content validity. Finally, the modified instrument was presented to patients during precognitive testing interviews to evaluate its clarity and appropriateness. Results: In total, 10 patients were enrolled in the focus groups and interview sessions where they identified 50 items. Once redundant items were removed, the 40 remaining items were made into a paper-and-pencil instrument referred to as the Pancreatitis Quality of Life Instrument. Through the processes of content validation and precognitive testing, the number of items in the instrument was reduced to 24. Conclusions: This marks the development of the first disease-specific instrument to evaluate quality of life in chronic pancreatitis. It includes unique features not found in generic instruments (economic factors, stigma, and spiritual factors. Although this marks a giant step forward, psychometric evaluation is still needed prior to its clinical use.

  14. Updates in the IR responsivity of VIR, the spectrometer of the Dawn mission.

    Science.gov (United States)

    Ammannito, Eleonora; Mc Cord, Thomas B.; De Sanctis, Maria Cristina.; Combe, Jean-Philippe

    VIR-MS (Visual and Infrared Mapping Spectrometer) is the imaging spectrometer of the Dawn mission (1,2). Here, first we describe the computation of a new instrument responsivity based on the internal calibration data acquired during the operations at Vesta, and then we describe its effect on the dataset and on the results published so far. VIR-MS was built in Italy by a scientific-industrial (IAPS/INAF in Rome (Italy) and Selex ES in Campi Bisenzio (Fi, Italy)) consortium financially supported by the Italian Space Agency. VIR-MS is an high spatial resolution spectrometer (FOV of 64mrad, IFOV of 250 µrad) in the 0.25-5 µm range with an IFOV of 250 µrad and a spectral sampling of about 2 nm in the visible range and 10 nm in the IR range. The results of the on-ground calibration held in the Selex calibration facility in September 2005 were already presented and discussed in a paper (2). This version has been used to calibrate the data available on the Planetary Data System (PDS) Small Bodies Node, dataset used in all the papers published so far. However, after the operations at the asteroid Vesta, we have identified some artifacts in the instrument responsivity in the 2.5-3.5 µm region, which is where several absorption bands of OH and H2O occur. Those artifacts were systematic, and therefore they did not prevent the detection of relative spectral variations associated to OH and H2O. Actually, the only paper published in which are discussed spectra in this range (3) used a different calibration method described in the paper itself. This method used a simple correction of the response function based on an empirical calibration correction that is appropriate to recover the signal in that specific range. However, the absolute absorption band depth of OH and H2O could not be calculated. To compute a new instrument responsivity we used the internal lamp of the spectrometer. This lamp, made of a tungsten filament, is characterized by a blackbody-like emission at about

  15. A Virtual Instrument System for Determining Sugar Degree of Honey

    Directory of Open Access Journals (Sweden)

    Qijun Wu

    2015-01-01

    Full Text Available This study established a LabVIEW-based virtual instrument system to measure optical activity through the communication of conventional optical instrument with computer via RS232 port. This system realized the functions for automatic acquisition, real-time display, data processing, results playback, and so forth. Therefore, it improved accuracy of the measurement results by avoiding the artificial operation, cumbersome data processing, and the artificial error in optical activity measurement. The system was applied to the analysis of the batch inspection on the sugar degree of honey. The results obtained were satisfying. Moreover, it showed advantages such as friendly man-machine dialogue, simple operation, and easily expanded functions.

  16. A Virtual Instrument System for Determining Sugar Degree of Honey.

    Science.gov (United States)

    Wu, Qijun; Gong, Xun

    2015-01-01

    This study established a LabVIEW-based virtual instrument system to measure optical activity through the communication of conventional optical instrument with computer via RS232 port. This system realized the functions for automatic acquisition, real-time display, data processing, results playback, and so forth. Therefore, it improved accuracy of the measurement results by avoiding the artificial operation, cumbersome data processing, and the artificial error in optical activity measurement. The system was applied to the analysis of the batch inspection on the sugar degree of honey. The results obtained were satisfying. Moreover, it showed advantages such as friendly man-machine dialogue, simple operation, and easily expanded functions.

  17. Evaluation of environmental policy instruments - a case study of the Finnish pulp and paper and chemical industries

    International Nuclear Information System (INIS)

    Hilden, M.; Lepola, J.; Mickwitz, P.; Palosaari, M.; Similae, J.; Sjoeblom, S.; Mulders, A.; Vedung, E.

    2002-01-01

    This research-based evaluation of environmental policy Instruments in Finland is focussed on regulatory instruments based on the Water Act, the Air Pollution Control Act and the Chemicals Act, on electricity taxation and on voluntary environmental management systems. The examined policy instruments have had several positive effects. They have directed major industrial point source polluters towards solving environmental problems. The transparency has been an important factor ensuring the success of the policy instruments and in avoiding the regulatory capture that could have thrived in a system largely based on negotiations between operators and authorities. The transparency has made it easy for Finnish firms to adopt environmental management systems and an open attitude to environmental reporting. The permit conditions have not directly resulted in innovations, but they have contributed to the diffusion of end-of-pipe technology and have contributed to innovations by expanding the market for environmentally better technical solutions. The permit systems have also indirectly contributed to innovations by creating a demand for environmental experts and environmental education. Networks have clearly developed as a consequence of and in response to regulatory instruments. These networks appear to have had their greatest significance prior to the permit procedures. The trend has been towards a greater emphasis of the communication in the networks prior to the presentation of an application in order to ensure a smoothly functioning permit process. In the networks contributing to innovations and the diffusion of innovations authorities have largely been outsiders, except when an innovation has become a de facto standard for permit conditions. The different kind of effects, the complexity of consequences and the uncertainties with respect to causes and effects mean that studies aiming at evaluating the overall worth and merit of an environmental policy instrument should

  18. Smarter by Degrees. Towards new instruments for energy conservation policy

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-11-15

    Achieving the government's ambition of 1.5 to 2% energy savings annually will require every effort to be made. Households, small and medium-sized businesses, government and semi-governmental institutions (energy-extensive energy consumers) will also be able to make an important contribution. This group represents considerable savings potential of about 300 PJ. There are three types of instruments that may be used for this group to achieve the desired goal (1) obligation/prohibition, i.e., regulations and standards to demand energy efficient investments (construction, facilities, equipment, etc.); (2) price incentives (subsidies/taxes) to promote energy-efficient solutions; (3)enticement/influence, appealing to reason (information, arguments) or emotion to promote the right choice/behaviour. Analysis of past experiences presents the conclusion that so-called soft instruments are sometimes briefly effective but often have little or no effect. The Council believes, however, that such a conclusion is premature, as certain conditions were not met in the past that were very important to effectiveness. First, soft instruments must be implemented consistently and over the long term (about 4 years, at least). Appealing to the very diverse consumers also requires a custom approach. The tone of the conservation policy must also be more in tune with changing trends in society. Citizens must especially be appealed to in terms of cost advantages, responsible energy consumption (good housekeeping) and comfort, whereas the emphasis in the past lay on decency, solidarity and thrift. Specific action perspectives must also be offered. Partly on the basis of experience, such as in waste collection, the Council concludes that a well-assembled mix of soft and hard instruments will be necessary to encourage energy conservation. It is clear that soft instruments alone can be expected to produce unsatisfactory results. Therefore, a combination of soft and hard instruments is advocated

  19. Functional, Responsive Materials Assembled from Recombinant Oleosin

    Science.gov (United States)

    Hammer, Daniel

    Biological cells are surrounded by a plasma membrane made primarily of phospholipids that form a bilayer. This membrane is permselective and compartmentalizes the cell. A simple form of artificial cell is the vesicle, in which a phospholipid bilayer membrane surrounds an aqueous solution. However, there is no a priori reason why a membrane needs to be made of phospholipids. It could be made of any surfactant that forms a bilayer. We have assembled membranes and other structures from the recombinant plant protein oleosin. The ability to assemble from a recombinant protein means that every molecule is identical, we have complete control over the sequence, and hence can build in designer functionality with high fidelity, including adhesion and enzymatic activity. Such incorporation is trivial using the tools of molecular biology. We find that while many variants of oleosin make membranes, others make micelles and sheets. We show how the type of supramolecular structure can be altered by the conditions of solvent, such as ionic strength, and the architecture of the surfactant itself. We show that protease cleavable domains can be incorporated within oleosin, and be engineered to protect other functional domains such as adhesive motifs, to make responsive materials whose activity and shape depend on the action of proteases. We will also present the idea of making ``Franken''-oleosins, where large domains of native oleosin are replaced with domains from other functional proteins, to make hybrids conferred by the donor protein. Thus, we can view oleosin as a template upon which a vast array of designer functionalities can be imparted..

  20. Evaluation of the Influence of Wording Changes and Course Type on Motivation Instrument Functioning in Chemistry

    Science.gov (United States)

    Komperda, Regis; Hosbein, Kathryn N.; Barbera, Jack

    2018-01-01

    Increased understanding of the importance of the affective domain in chemistry education research has led to the development and adaptation of instruments to measure chemistry-specific affective traits, including motivation. Many of these instruments are adapted from other fields by using the word "chemistry" in place of other…