WorldWideScience

Sample records for instrument internal consistency

  1. The Karen instruments for measuring quality of nursing care: construct validity and internal consistency.

    Science.gov (United States)

    Lindgren, Margareta; Andersson, Inger S

    2011-06-01

    Valid and reliable instruments for measuring the quality of care are needed for evaluation and improvement of nursing care. Previously developed and evaluated instruments, the Karen-patient and the Karen-personnel based on Donabedian's Structure-Process-Outcome triad (S-P-O triad) had promising content validity, discriminative power and internal consistency. The objective of this study was to further develop the instruments with regard to construct validity and internal consistency. This prospective study was carried out in medical and surgical wards at a hospital in Sweden. A total of 95 patients and 120 personnel were included. The instruments were tested for construct validity by performing factor analyses in two steps and for internal consistency using Cronbach's alpha coefficient. The first confirmatory factor analyses, with a pre-determined three-factor solution did not load well according to the S-P-O triad, but the second exploratory factor analysis with a six-factor solution appeared to be more coherent and the distribution of variables seemed to be logical. The reliability, i.e. internal consistency, was good in both factor analyses. The Karen-patient and the Karen-personnel instruments have achieved acceptable levels of construct validity. The internal consistency of the instruments is good. This indicates that the instruments may be suitable to use in clinical practice for measuring the quality of nursing care.

  2. Construct validity and internal consistency in the Leisure Practices Scale (EPL) for adults.

    Science.gov (United States)

    Andrade, Rubian Diego; Schwartz, Gisele Maria; Tavares, Giselle Helena; Pelegrini, Andreia; Teixeira, Clarissa Stefani; Felden, Érico Pereira Gomes

    2018-02-01

    This study proposes and analyzes the construct validity and internal consistency of the Leisure Practices Scale (EPL). This survey seeks to identify the preferences and involvement in in different leisure practices in adults. The instrument was formed based on the cultural leisure content (artistic, manual, physical, sports, intellectual, social, tourist, virtual and contemplation/leisure). The validation process was conducted with: a) content analysis by leisure experts, who evaluated the instrument for clarity of language and practical relevance, which allowed the calculation of the content validity coefficient (CVC); b) reproducibility test-retest with 51 subjects to calculate the temporal variation coefficient; c) internal consistency analysis with 885 participants. The evaluation presented appropriate coefficients, both with respect to language clarity (CVCt = 0.883) and practical relevance (CVCt = 0.879). The reproducibility coefficients were moderate to excellent. The scale showed adequate internal consistency (0.72). The EPL has psychometric quality and acceptable values in its structure, and can be used to investigate adult involvement in leisure activities.

  3. International Survey on agriculture-climate change policy instruments

    Energy Technology Data Exchange (ETDEWEB)

    Fernagut, M.; Priem, M.; Sorgeloos, L.

    2011-09-15

    The title study provides an international overview of agriculture-climate change policy instruments for the reduction of methane and nitrous oxide emissions. The aim of this study is to clarify how national and/or international agriculture-climate-policies could or should be instrumented during the coming three to five years to achieve significant emission reductions of methane and nitrous oxide in the Dutch agricultural sector by 2020. The study includes an international survey, a quick-scan inventory of useful and inspiring examples of policy and reduction measures to reduce non CO2 greenhouse gases. ERM used an approach consisting out of three phases. In the first phase countries were selected on the basis of emissions and Kyoto protocol targets. In the second phase policy measures of these countries were listed, based on publicly available national and international sources. In a third phase a sub-set of this selection was analyzed in-depth through communications with local focal points and additional review of policy documents, to enhance the understanding of context, impact and results of each of these policies and measures.

  4. Choice, internal consistency, and rationality

    OpenAIRE

    Aditi Bhattacharyya; Prasanta K. Pattanaik; Yongsheng Xu

    2010-01-01

    The classical theory of rational choice is built on several important internal consistency conditions. In recent years, the reasonableness of those internal consistency conditions has been questioned and criticized, and several responses to accommodate such criticisms have been proposed in the literature. This paper develops a general framework to accommodate the issues raised by the criticisms of classical rational choice theory, and examines the broad impact of these criticisms from both no...

  5. Fabrication of internally instrumented reactor fuel rods

    International Nuclear Information System (INIS)

    Schmutz, J.D.; Meservey, R.H.

    1975-01-01

    Procedures are outlined for fabricating internally instrumented reactor fuel rods while maintaining the original quality assurance level of the rods. Instrumented fuel rods described contain fuel centerline thermocouples, ultrasonic thermometers, and pressure tubes for internal rod gas pressure measurements. Descriptions of the thermocouples and ultrasonic thermometers are also contained

  6. Content validation: clarity/relevance, reliability and internal consistency of enunciative signs of language acquisition.

    Science.gov (United States)

    Crestani, Anelise Henrich; Moraes, Anaelena Bragança de; Souza, Ana Paula Ramos de

    2017-08-10

    To analyze the results of the validation of building enunciative signs of language acquisition for children aged 3 to 12 months. The signs were built based on mechanisms of language acquisition in an enunciative perspective and on clinical experience with language disorders. The signs were submitted to judgment of clarity and relevance by a sample of six experts, doctors in linguistic in with knowledge of psycholinguistics and language clinic. In the validation of reliability, two judges/evaluators helped to implement the instruments in videos of 20% of the total sample of mother-infant dyads using the inter-evaluator method. The method known as internal consistency was applied to the total sample, which consisted of 94 mother-infant dyads to the contents of the Phase 1 (3-6 months) and 61 mother-infant dyads to the contents of Phase 2 (7 to 12 months). The data were collected through the analysis of mother-infant interaction based on filming of dyads and application of the parameters to be validated according to the child's age. Data were organized in a spreadsheet and then converted to computer applications for statistical analysis. The judgments of clarity/relevance indicated no modifications to be made in the instruments. The reliability test showed an almost perfect agreement between judges (0.8 ≤ Kappa ≥ 1.0); only the item 2 of Phase 1 showed substantial agreement (0.6 ≤ Kappa ≥ 0.79). The internal consistency for Phase 1 had alpha = 0.84, and Phase 2, alpha = 0.74. This demonstrates the reliability of the instruments. The results suggest adequacy as to content validity of the instruments created for both age groups, demonstrating the relevance of the content of enunciative signs of language acquisition.

  7. Factorial Validity and Internal Consistency of Malaysian Adapted Depression Anxiety Stress Scale - 21 in an Adolescent Sample

    OpenAIRE

    Hairul Anuar Hashim; Freddy Golok; Rosmatunisah Ali

    2011-01-01

    Background: Psychometrically sound measurement instrument is a fundamental requirement across broad range of research areas. In negative affect research, Depression Anxiety Stress Scale (DASS) has been identified as a psychometrically sound instrument to measure depression, anxiety and stress, especially the 21-item version. However, its psychometric properties in adolescents have been less consistent. Objectives: Thus, the present study sought to examine the factorial validity and internal c...

  8. Factor Structure, Internal Consistency, and Screening Sensitivity of the GARS-2 in a Developmental Disabilities Sample

    Directory of Open Access Journals (Sweden)

    Martin A. Volker

    2016-01-01

    Full Text Available The Gilliam Autism Rating Scale-Second Edition (GARS-2 is a widely used screening instrument that assists in the identification and diagnosis of autism. The purpose of this study was to examine the factor structure, internal consistency, and screening sensitivity of the GARS-2 using ratings from special education teaching staff for a sample of 240 individuals with autism or other significant developmental disabilities. Exploratory factor analysis yielded a correlated three-factor solution similar to that found in 2005 by Lecavalier for the original GARS. Though the three factors appeared to be reasonably consistent with the intended constructs of the three GARS-2 subscales, the analysis indicated that more than a third of the GARS-2 items were assigned to the wrong subscale. Internal consistency estimates met or exceeded standards for screening and were generally higher than those in previous studies. Screening sensitivity was .65 and specificity was .81 for the Autism Index using a cut score of 85. Based on these findings, recommendations are made for instrument revision.

  9. The Nurses Self-Concept Instrument (NSCI): assessment of psychometric properties for Australian domestic and international student nurses.

    Science.gov (United States)

    Angel, Elizabeth; Craven, Rhonda; Denson, Nida

    2012-07-01

    Professional self-concept is a critical driver of job satisfaction. In Australia, as international nursing enrolments rise, nursing is increasingly characterised by a professional body of international nurses who may differ from domestic Australian nurses in their nursing self-concept. At present, no psychometrically sound instrument for assessing nursing self-concept for Australian domestic and international nursing students is available. The purpose of this study was to: (1) develop an instrument (the Nurses' Self-Concept Instrument (NSCI)) to measure the professional self-concept of domestic and international nursing students in Australia, and (2) test the psychometric properties of this newly developed instrument. A literature review was conducted to generate the initial dimension and item pools to measure nurses' professional self-concept (NSCI). Two stakeholders examined the content and face validity of dimensions and items. Analysis was performed on data collected from 253 undergraduate nursing students in a large public university in Sydney, Australia, and consisted of domestic (n=218) and international (n=35) nursing students. Internal reliability was assessed using Cronbach's Alpha. Confirmatory factor analysis (CFA) was used to assess the construct validity of the NSCI. The resulting NSCI consisted of 14 items across four self-concept domains: care, leadership, staff relations, and knowledge. The CFA supported the hypothesised factor structure of the self-concept model. All reliabilities were acceptable for both domestic and international students (ranging from r=.78 to .93). The NSCI was shown to be a valid and reliable tool for assessing Australian domestic and international student nurses' professional self-concept. This instrument may also enable those responsible for recruitment of students into nursing courses to assess students' professional self-concept and implement appropriate strategies to foster the growth of lifelong career development

  10. Development of an instrument to measure internalized stigma in those with HIV/AIDS.

    Science.gov (United States)

    Phillips, Kenneth D; Moneyham, Linda; Tavakoli, Abbas

    2011-01-01

    Stigma has grave consequences for persons living with HIV/AIDS. Stigma hampers prevention of HIV transmission to sexual partners and to unborn babies, diagnosis, and early treatment, and negatively affects mental and physical health, quality of life, and life satisfaction. Internalized stigma of HIV/AIDS may have even more severe consequences than perceived or enacted stigma. The purpose of this study was to develop an instrument to measure internalized stigma in those with HIV/AIDS. Data were drawn from the Rural Women's Health Project. Research assistants administered structured interviews at baseline, 3 months, and 6 months. Instruments used in these analyses included a demographic data form, the Centers for Epidemiological Studies Depression Scale (CES-D), the Perceived Stigma Scale (PSS), and the Internalized Stigma of AIDS Tool (ISAT). Exploratory factor analysis confirmed that the ten items of the ISAT measure a single factor that explains 88% of the variance in the construct. Internal consistency was demonstrated by a Cronbach's alpha of .91 (Time 1), .92 (Time 2), and .92 (Time 3). Convergent validity was supported with significant positive correlations with the CES-D (rho = 0.33, p Stigma of AIDS Tool appears to be a reliable and valid instrument to measure internalization of the stigma of HIV/AIDS. It may be of value in research and clinical assessment.

  11. Delimiting Coefficient a from Internal Consistency and Unidimensionality

    Science.gov (United States)

    Sijtsma, Klaas

    2015-01-01

    I discuss the contribution by Davenport, Davison, Liou, & Love (2015) in which they relate reliability represented by coefficient a to formal definitions of internal consistency and unidimensionality, both proposed by Cronbach (1951). I argue that coefficient a is a lower bound to reliability and that concepts of internal consistency and…

  12. Test of Gross Motor Development : Expert Validity, confirmatory validity and internal consistence

    Directory of Open Access Journals (Sweden)

    Nadia Cristina Valentini

    2008-12-01

    Full Text Available The Test of Gross Motor Development (TGMD-2 is an instrument used to evaluate children’s level of motordevelopment. The objective of this study was to translate and verify the clarity and pertinence of the TGMD-2 items by expertsand the confirmatory factorial validity and the internal consistence by means of test-retest of the Portuguese TGMD-2. Across-cultural translation was used to construct the Portuguese version. The participants of this study were 7 professionalsand 587 children, from 27 schools (kindergarten and elementary from 3 to 10 years old (51.1% boys and 48.9% girls.Each child was videotaped performing the test twice. The videotaped tests were then scored. The results indicated thatthe Portuguese version of the TGMD-2 contains clear and pertinent motor items; demonstrated satisfactory indices ofconfirmatory factorial validity (χ2/gl = 3.38; Goodness-of-fit Index = 0.95; Adjusted Goodness-of-fit index = 0.92 and Tuckerand Lewis’s Index of Fit = 0.83 and test-retest internal consistency (locomotion r = 0.82; control of object: r = 0.88. ThePortuguese TGMD-2 demonstrated validity and reliability for the sample investigated.

  13. Test of Gross Motor Development: expert validity, confirmatory validity and internal consistence

    Directory of Open Access Journals (Sweden)

    Nadia Cristina Valentini

    2008-01-01

    The Test of Gross Motor Development (TGMD-2 is an instrument used to evaluate children’s level of motor development. The objective of this study was to translate and verify the clarity and pertinence of the TGMD-2 items by experts and the confirmatory factorial validity and the internal consistence by means of test-retest of the Portuguese TGMD-2. A cross-cultural translation was used to construct the Portuguese version. The participants of this study were 7 professionals and 587 children, from 27 schools (kindergarten and elementary from 3 to 10 years old (51.1% boys and 48.9% girls. Each child was videotaped performing the test twice. The videotaped tests were then scored. The results indicated that the Portuguese version of the TGMD-2 contains clear and pertinent motor items; demonstrated satisfactory indices of confirmatory factorial validity (÷2/gl = 3.38; Goodness-of-fit Index = 0.95; Adjusted Goodness-of-fit index = 0.92 and Tucker and Lewis’s Index of Fit = 0.83 and test-retest internal consistency (locomotion r = 0.82; control of object: r = 0.88. The Portuguese TGMD-2 demonstrated validity and reliability for the sample investigated.

  14. The Internal Consistency Reliability of the Katz-Francis Scale of Attitude toward Judaism among Australian Jews

    Directory of Open Access Journals (Sweden)

    Patrick Lumbroso

    2016-09-01

    Full Text Available The Katz-Francis Scale of Attitude toward Judaism was developed initially to extend among the Hebrew-speaking Jewish community in Israel a growing body of international research concerned to map the correlates, antecedents and consequences of individual differences in attitude toward religion as assessed by the Francis Scale of Attitude toward Christianity. The present paper explored the internal consistency reliability and construct validity of the English translation of the Katz-Francis Scale of Attitude toward Judaism among 101 Australian Jews. On the basis of these data, this instrument is commended for application in further research.

  15. Internal communication: challenges and instruments

    International Nuclear Information System (INIS)

    Stiopol, Mihaela; Rizea, Lavinia

    2007-01-01

    Mike Hughes, the publisher for Publicity Express once said that 'Without Public Relations a terrible thing happens: nothing'. The term 'Public Relations' describes the efficient and coherent organization of external and internal communication. A company has an external public and an internal one as well. The employees of an organization are important carriers of the message the organization wants to transmit, but moreover, they are the driving engine behind the success of an enterprise. Better informed employees are more confident and prepared to get involved in challenging tasks such as obtaining public support for nuclear power. Internal communication is the continuous flux of information on all hierarchic levels both horizontally and vertically. The efficient usage of internal communication tools brings great advantages and benefits for the managers and the personnel of an organization. Despite this, organizing an integrated internal communication strategy is a challenging effort for any PR department. The paper deals with the instruments of internal communication, the obstacles usually encountered and the possibilities to apply an integrated strategy in large companies operating in the nuclear field. (authors)

  16. Development and validation of an international appraisal instrument for assessing the quality of clinical practice guidelines: the AGREE project.

    Science.gov (United States)

    2003-02-01

    International interest in clinical practice guidelines has never been greater but many published guidelines do not meet the basic quality requirements. There have been renewed calls for validated criteria to assess the quality of guidelines. To develop and validate an international instrument for assessing the quality of the process and reporting of clinical practice guideline development. The instrument was developed through a multi-staged process of item generation, selection and scaling, field testing, and refinement procedures. 100 guidelines selected from 11 participating countries were evaluated independently by 194 appraisers with the instrument. Following refinement the instrument was further field tested on three guidelines per country by a new set of 70 appraisers. The final version of the instrument contained 23 items grouped into six quality domains with a 4 point Likert scale to score each item (scope and purpose, stakeholder involvement, rigour of development, clarity and presentation, applicability, editorial independence). 95% of appraisers found the instrument useful for assessing guidelines. Reliability was acceptable for most domains (Cronbach's alpha 0.64-0.88). Guidelines produced as part of an established guideline programme had significantly higher scores on editorial independence and, after the publication of a national policy, had significantly higher quality scores on rigour of development (pinternationally. The instrument is sensitive to differences in important aspects of guidelines and can be used consistently and easily by a wide range of professionals from different backgrounds. The adoption of common standards should improve the consistency and quality of the reporting of guideline development worldwide and provide a framework to encourage international comparison of clinical practice guidelines.

  17. Factor Structure, Internal Consistency, and Screening Sensitivity of the GARS-2 in a Developmental Disabilities Sample

    OpenAIRE

    Martin A. Volker; Elissa H. Dua; Christopher Lopata; Marcus L. Thomeer; Jennifer A. Toomey; Audrey M. Smerbeck; Jonathan D. Rodgers; Joshua R. Popkin; Andrew T. Nelson; Gloria K. Lee

    2016-01-01

    The Gilliam Autism Rating Scale-Second Edition (GARS-2) is a widely used screening instrument that assists in the identification and diagnosis of autism. The purpose of this study was to examine the factor structure, internal consistency, and screening sensitivity of the GARS-2 using ratings from special education teaching staff for a sample of 240 individuals with autism or other significant developmental disabilities. Exploratory factor analysis yielded a correlated three-factor solution si...

  18. The memory failures of everyday questionnaire (MFE): internal consistency and reliability.

    Science.gov (United States)

    Montejo Carrasco, Pedro; Montenegro, Peña Mercedes; Sueiro, Manuel J

    2012-07-01

    The Memory Failures of Everyday Questionnaire (MFE) is one of the most widely-used instruments to assess memory failures in daily life. The original scale has nine response options, making it difficult to apply; we created a three-point scale (0-1-2) with response choices that make it easier to administer. We examined the two versions' equivalence in a sample of 193 participants between 19 and 64 years of age. The test-retest reliability and internal consistency of the version we propose were also computed in a sample of 113 people. Several indicators attest to the two forms' equivalence: the correlation between the items' means (r = .94; p MFE 1-9. The MFE 0-2 provides a brief, simple evaluation, so we recommend it for use in clinical practice as well as research.

  19. International standardization of instruments for neutron irradiation tests

    International Nuclear Information System (INIS)

    Tanimoto, Masataka; Shibata, Akira; Nakamura, Jinichi; Tsuchiya, Kunihiko; Cho, M.; Lee, C.; Park, S.; Choo, K.

    2012-01-01

    The JMTR in JAEA and HANARO in KAERI are the foremost testing/research reactors in the world and these are expected to contribute to many nuclear fields. As a part of instrument development in irradiation field, information exchange of instruments started from 2010 under the cooperation agreements between KAERI and JAEA. The instruments developed in JMTR and HANARO are introduced and cooperation experiments as future plan are discussed for international standardization. (author)

  20. Nonlinear internal friction, chaos, fractal and musical instruments

    International Nuclear Information System (INIS)

    Sun, Z.Q.; Lung, C.W.

    1995-08-01

    Nonlinear and structure sensitive internal friction phenomena in materials are used for characterizing musical instruments. It may be one of the most important factors influencing timbre of instruments. As a nonlinear dissipated system, chaos and fractals are fundamental peculiarities of sound spectra. It is shown that the concept of multi range fractals can be used to decompose the frequency spectra of melody. New approaches are suggested to improve the fabrication, property characterization and physical understanding of instruments. (author). 18 refs, 4 figs

  1. Internal Branding and Employee Brand Consistent Behaviours

    DEFF Research Database (Denmark)

    Mazzei, Alessandra; Ravazzani, Silvia

    2017-01-01

    constitutive processes. In particular, the paper places emphasis on the role and kinds of communication practices as a central part of the nonnormative and constitutive internal branding process. The paper also discusses an empirical study based on interviews with 32 Italian and American communication managers...... and 2 focus groups with Italian communication managers. Findings show that, in order to enhance employee brand consistent behaviours, the most effective communication practices are those characterised as enablement-oriented. Such a communication creates the organizational conditions adequate to sustain......Employee behaviours conveying brand values, named brand consistent behaviours, affect the overall brand evaluation. Internal branding literature highlights a knowledge gap in terms of communication practices intended to sustain such behaviours. This study contributes to the development of a non...

  2. International Approaches to Financial Instruments and Their Application in Ukraine

    OpenAIRE

    Viktor Zamlynskyy

    2013-01-01

    Introduction of International Financial Reporting Standards in Ukraine requires scientific and methodological study of their specific use in national practice. The essence and types of financial instruments have been researched. The regulatory support for their accounting in Ukraine has been established. The authors have analyzed the provisions of the International Financial Reporting Standards governing the financial instruments accounting, worked out characteristics of existing methodology ...

  3. Consistência interna da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN Internal consistency of the Portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN

    Directory of Open Access Journals (Sweden)

    Gustavo J. Fonseca D'El Rey

    2007-01-01

    Full Text Available CONTEXTO: A fobia social é um grave transtorno de ansiedade que traz incapacitação e sofrimento. OBJETIVOS: Investigar a consistência interna da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN. MÉTODOS: Foi realizado um estudo da consistência interna do Mini-SPIN em uma amostra de 206 estudantes universitários da cidade de São Paulo, SP. RESULTADOS: A consistência interna do instrumento, analisada pelo coeficiente alfa de Cronbach, foi de 0,81. CONCLUSÕES: Esses achados permitiram concluir que a versão em português do Mini-SPIN exibiu resultados de boa consistência interna, semelhantes aos da versão original em inglês.BACKGROUND: Social phobia is a severe anxiety disorder that brings disability and distress. OBJECTIVES: To investigate the internal consistency of the Portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN. METHODS: We conducted a study of internal consistency of the Mini-SPIN in a sample of 206 college students of the city of São Paulo, SP. RESULTS: The internal consistency of the instrument, analyzed by Cronbach's alpha coefficient, was 0.81. CONCLUSIONS: These findings suggest that the Portuguese version of the Mini-SPIN has a good internal consistency, similar to those obtained with the original English version.

  4. The Role of International Law: Formulating International Legal Instruments and Creating International Institutions.

    Science.gov (United States)

    Szasz, Paul C.

    1991-01-01

    Using as a basis the threat of climatic change resulting from global warming, this article considers the functions that might be assigned to an international regime. For each function individually and collectively, the instruments and institutions that would be required for the various processes are examined. (SLD)

  5. [Discomfort associated with dental extraction surgery and development of a questionnaire (QCirDental). Part I: Impacts and internal consistency].

    Science.gov (United States)

    Bortoluzzi, Marcelo Carlos; Martins, Luciana Dorochenko; Takahashi, André; Ribeiro, Bianca; Martins, Ligiane; Pinto, Marcia Helena Baldani

    2018-01-01

    The scope of this study was to develop and validate a questionnaire (QCirDental) to measure the impacts associated with dental extraction surgery. The QCirDental questionnaire was developed in two steps; (1) question and item generation and selection, and (2) pretest of the questionnaire with evaluation of the its measurement properties (internal consistency and responsiveness). The sample was composed of 123 patients. None of the patients had any difficulty in understanding the QCirDental. The instrument was found to have excellent internal consistency with Cronbach's alpha reliability coefficient of 0.83. The principal component analysis (Kaiser-Meyer-Olkin Measure of Sampling Adequacy 0,72 and Bartlett's Test of Sphericity with p < 0.001) showed six (6) dimensions explaining 67.5% of the variance. The QCirDental presented excellent internal consistency, being a questionnaire that is easy to read and understand with adequate semantic and content validity. More than 80% of the patients who underwent dental extraction reported some degree of discomfort within the perioperative period which highlights the necessity to assess the quality of care and impacts of dental extraction surgery.

  6. Instrumental motives in negative emotion regulation in daily life: Frequency, consistency, and predictors.

    Science.gov (United States)

    Kalokerinos, Elise K; Tamir, Maya; Kuppens, Peter

    2017-06-01

    People regulate their emotions not only for hedonic reasons but also for instrumental reasons, to attain the potential benefits of emotions beyond pleasure and pain. However, such instrumental motives have rarely been examined outside the laboratory as they naturally unfold in daily life. To assess whether and how instrumental motives operate outside the laboratory, it is necessary to examine them in response to real and personally relevant stimuli in ecologically valid contexts. In this research, we assessed the frequency, consistency, and predictors of instrumental motives in negative emotion regulation in daily life. Participants (N = 114) recalled the most negative event of their day each evening for 7 days and reported their instrumental motives and negative emotion goals in that event. Participants endorsed performance motives in approximately 1 in 3 events and social, eudaimonic, and epistemic motives in approximately 1 in 10 events. Instrumental motives had substantially higher within- than between-person variance, indicating that they were context-dependent. Indeed, although we found few associations between instrumental motives and personality traits, relationships between instrumental motives and contextual variables were more extensive. Performance, social, and epistemic motives were each predicted by a unique pattern of contextual appraisals. Our data demonstrate that instrumental motives play a role in daily negative emotion regulation as people encounter situations that pose unique regulatory demands. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  7. Agreements on climatic protection - the verification problem. IKARUS. Instrumente fuer Klimagas-Reduktionsstrategien. Final report. Subproject 9: International Greenhouse Gas Verification

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, W.; Hoffmann, H.J.; Katscher, W.; Kotte, U.; Lauppe, W.D.; Stein, G.

    1995-12-31

    The sustained reduction of climate gas emissions associated with the generation, conversion and utilization of energy is clearly becoming an ever more important task in energy and environmental policy. Different strategies are conceivable in order to fulfil this mission. The aim of the IKARUS Project (Instrumente fuer Klimagas-Reduktionsstrategien - Instruments for Greenhouse Gas Reduction Strategies) was to provide a set of tools with which strategies can be developed and reconstructed (making conceptual use of the various technologies) and also tested with respect to their internal consistency and examined with regard to their economic impacts. Corresponding to the great complexity of the task in hand and the technological range of energy applications, the set of instruments is very extensive. It consists of two parts: a data base with a comprehensive data collection and several computer models of various types.The ``Verification`` project was integrated into IKARUS as a link between the national project and the international environment, enabling the examination of technologies and methods for verifying the compliance of statesparty to the Framwork Convention on Climate Change (FCCC).(orig/KW)

  8. Psychometric analyses and internal consistency of the PHEEM questionnaire to measure the clinical learning environment in the clerkship of a Medical School in Chile.

    Science.gov (United States)

    Riquelme, Arnoldo; Herrera, Cristian; Aranis, Carolina; Oporto, Jorge; Padilla, Oslando

    2009-06-01

    The Spanish version of the Postgraduate Hospital Educational Environment Measure (PHEEM) was evaluated in this study to determine its psychometric properties, validity and internal consistency to measure the clinical learning environment in the hospital setting of Pontificia Universidad Católica de Chile Medical School's Internship. The 40-item PHEEM questionnaire was translated from English to Spanish and retranslated to English. Content validity was tested by a focus group and minor differences in meaning were adjusted. The PHEEM was administered to clerks in years 6 and 7. Construct validity was carried out using exploratory factor analysis followed by a Varimax rotation. Internal consistency was measured using Cronbach's alpha. A total of 125 out of 220 students responded to the PHEEM. The overall response rate was 56.8% and compliances with each item ranged from 99.2% to 100%. Analyses indicate that five factors instrument accounting for 58% of the variance and internal consistency of the 40-item questionnaire is 0.955 (Cronbach's alpha). The 40-item questionnaire had a mean score of 98.21 +/- 21.2 (maximum score of 160). The Spanish version of PHEEM is a multidimensional, valid and highly reliable instrument measuring the educational environment among undergraduate medical students working in hospital-based clerkships.

  9. Felder-Soloman's Index of Learning Styles: internal consistency, temporal stability, and factor structure.

    Science.gov (United States)

    Hosford, Charles C; Siders, William A

    2010-10-01

    Strategies to facilitate learning include using knowledge of students' learning style preferences to inform students and their teachers. Aims of this study were to evaluate the factor structure, internal consistency, and temporal stability of medical student responses to the Index of Learning Styles (ILS) and determine its appropriateness as an instrument for medical education. The ILS assesses preferences on four dimensions: sensing/intuitive information perceiving, visual/verbal information receiving, active/reflective information processing, and sequential/global information understanding. Students entering the 2002-2007 classes completed the ILS; some completed the ILS again after 2 and 4 years. Analyses of responses supported the ILS's intended structure and moderate reliability. Students had moderate preferences for sensing and visual learning. This study provides evidence supporting the appropriateness of the ILS for assessing learning style preferences in medical students.

  10. Virtual Instrument for Emissions Measurement of Internal Combustion Engines

    Science.gov (United States)

    Pérez, Armando; Montero, Gisela; Coronado, Marcos; García, Conrado; Pérez, Rubén

    2016-01-01

    The gases emissions measurement systems in internal combustion engines are strict and expensive nowadays. For this reason, a virtual instrument was developed to measure the combustion emissions from an internal combustion diesel engine, running with diesel-biodiesel mixtures. This software is called virtual instrument for emissions measurement (VIEM), and it was developed in the platform of LabVIEW 2010® virtual programming. VIEM works with sensors connected to a signal conditioning system, and a data acquisition system is used as interface for a computer in order to measure and monitor in real time the emissions of O2, NO, CO, SO2, and CO2 gases. This paper shows the results of the VIEM programming, the integrated circuits diagrams used for the signal conditioning of sensors, and the sensors characterization of O2, NO, CO, SO2, and CO2. VIEM is a low-cost instrument and is simple and easy to use. Besides, it is scalable, making it flexible and defined by the user. PMID:27034893

  11. Virtual Instrument for Emissions Measurement of Internal Combustion Engines.

    Science.gov (United States)

    Pérez, Armando; Ramos, Rogelio; Montero, Gisela; Coronado, Marcos; García, Conrado; Pérez, Rubén

    2016-01-01

    The gases emissions measurement systems in internal combustion engines are strict and expensive nowadays. For this reason, a virtual instrument was developed to measure the combustion emissions from an internal combustion diesel engine, running with diesel-biodiesel mixtures. This software is called virtual instrument for emissions measurement (VIEM), and it was developed in the platform of LabVIEW 2010® virtual programming. VIEM works with sensors connected to a signal conditioning system, and a data acquisition system is used as interface for a computer in order to measure and monitor in real time the emissions of O2, NO, CO, SO2, and CO2 gases. This paper shows the results of the VIEM programming, the integrated circuits diagrams used for the signal conditioning of sensors, and the sensors characterization of O2, NO, CO, SO2, and CO2. VIEM is a low-cost instrument and is simple and easy to use. Besides, it is scalable, making it flexible and defined by the user.

  12. Comment on the internal consistency of thermodynamic databases supporting repository safety assessments

    International Nuclear Information System (INIS)

    Arthur, R.C.

    2001-11-01

    This report addresses the concept of internal consistency and its relevance to the reliability of thermodynamic databases used in repository safety assessments. In addition to being internally consistent, a reliable database should be accurate over a range of relevant temperatures and pressures, complete in the sense that all important aqueous species, gases and solid phases are represented, and traceable to original experimental results. No single definition of internal consistency need to be universally accepted as the most appropriate under all conditions, however. As a result, two databases that are each internally consistent may be inconsistent with respect to each other, and a database derived from two or more such databases must itself be internally inconsistent. The consequences of alternative definitions that are reasonably attributable to the concept of internal consistency can be illustrated with reference to the thermodynamic database supporting SKB's recent SR 97 safety assessment. This database is internally inconsistent because it includes equilibrium constants calculated over a range of temperatures: using conflicting reference values for some solids, gases and aqueous species that are common to two internally consistent databases (the OECD/NEA database for radioelements and SUPCRT databases for non-radioactive elements) that serve as source databases for the SR 97 TDB, using different definitions in these source databases of standard states for condensed phases and aqueous species, based on different mathematical expressions used in these source databases representing the temperature dependence of the heat capacity, and based on different chemical models adopted in these source databases for the aqueous phase. The importance of such inconsistencies must be considered in relation to the other database reliability criteria noted above, however. Thus, accepting a certain level of internal inconsistency in a database it is probably preferable to use a

  13. Comment on the internal consistency of thermodynamic databases supporting repository safety assessments

    Energy Technology Data Exchange (ETDEWEB)

    Arthur, R.C. [Monitor Scientific, LLC, Denver, CO (United States)

    2001-11-01

    This report addresses the concept of internal consistency and its relevance to the reliability of thermodynamic databases used in repository safety assessments. In addition to being internally consistent, a reliable database should be accurate over a range of relevant temperatures and pressures, complete in the sense that all important aqueous species, gases and solid phases are represented, and traceable to original experimental results. No single definition of internal consistency need to be universally accepted as the most appropriate under all conditions, however. As a result, two databases that are each internally consistent may be inconsistent with respect to each other, and a database derived from two or more such databases must itself be internally inconsistent. The consequences of alternative definitions that are reasonably attributable to the concept of internal consistency can be illustrated with reference to the thermodynamic database supporting SKB's recent SR 97 safety assessment. This database is internally inconsistent because it includes equilibrium constants calculated over a range of temperatures: using conflicting reference values for some solids, gases and aqueous species that are common to two internally consistent databases (the OECD/NEA database for radioelements and SUPCRT databases for non-radioactive elements) that serve as source databases for the SR 97 TDB, using different definitions in these source databases of standard states for condensed phases and aqueous species, based on different mathematical expressions used in these source databases representing the temperature dependence of the heat capacity, and based on different chemical models adopted in these source databases for the aqueous phase. The importance of such inconsistencies must be considered in relation to the other database reliability criteria noted above, however. Thus, accepting a certain level of internal inconsistency in a database it is probably preferable to

  14. Private International Law Issues in Opt-out and Opt-in Instruments of Harmonization

    DEFF Research Database (Denmark)

    Fogt, Morten Midtgaard

    2013-01-01

    of Goods from 1980 (CISG) and the European Commission Proposal for a common European Sales Law from 2011 (CESL). Although the two instruments of substantial harmonization regulate the same area of civil law, they differ with respect to the type of formal instrument of harmonization, the material, personal......This article deals with opt-in and opt-out instruments of harmonization, how they apply and compete. It analyses the Private International Law (PIL) issues which arise and bases the analysis on the two instruments of harmonization – the Vienna Convention on Contract for the International Sale...... into these questions and argues, inter alia, that the CISG as a global international convention should have priority over the regional CESL, that the choice of the CESL should be based on a PIL choice of binding European ‘Community rules of law’, that both instruments cannot possible overrule the established PIL...

  15. Internally consistent gamma ray burst time history phenomenology

    International Nuclear Information System (INIS)

    Cline, T.L.

    1985-01-01

    A phenomenology for gamma ray burst time histories is outlined. Order of their generally chaotic appearance is attempted, based on the speculation that any one burst event can be represented above 150 keV as a superposition of similarly shaped increases of varying intensity. The increases can generally overlap, however, confusing the picture, but a given event must at least exhibit its own limiting characteristic rise and decay times if the measurements are made with instruments having adequate temporal resolution. Most catalogued observations may be of doubtful or marginal utility to test this hypothesis, but some time histories from Helios-2, Pioneer Venus Orbiter and other instruments having one-to several-millisecond capabilities appear to provide consistency. Also, recent studies of temporally resolved Solar Maximum Mission burst energy spectra are entirely compatible with this picture. The phenomenology suggested here, if correct, may assist as an analytic tool for modelling of burst processes and possibly in the definition of burst source populations

  16. Happiness as stable extraversion : internal consistency reliability and construct validity of the Oxford Happiness Questionnaire among undergraduate students\\ud \\ud

    OpenAIRE

    Robbins, Mandy; Francis, Leslie J.; Edwards, Bethan

    2010-01-01

    The Oxford Happiness Questionnaire (OHQ) was developed by Hills and Argyle (2002) to provide a more accessible equivalent measure of the Oxford Happiness Inventory (OHI). The aim of the present study was to examine the internal consistency reliability, and construct validity of this new instrument alongside the Eysenckian dimensional model of personality. The Oxford Happiness Questionnaire was completed by a sample of 131 undergraduate students together with the abbreviated form of the Revise...

  17. The Legal Strength of International Health Instruments - What It Brings to Global Health Governance?

    Directory of Open Access Journals (Sweden)

    Haik Nikogosian

    2016-12-01

    Full Text Available Public health instruments have been under constant development and renewal for decades. International legal instruments, with their binding character and strength, have a special place in this development. The start of the 21st century saw, in particular, the birth of the first World Health Organization (WHO-era health treaties – the WHO Framework Convention on Tobacco Control (WHO FCTC and its first Protocol. The authors analyze the potential impact of these instruments on global health governance and public health, beyond the traditional view of their impact on tobacco control. Overall, the very fact that globally binding treaties in modern-era health were feasible has accelerated the debate and expectations for an expanded role of international legal regimes in public health. The impact of treaties has also been notable in global health architecture as the novel instruments required novel institutions to govern their implementation. The legal power of the WHO FCTC has enabled rapid adoption of further instruments to promote its implementation, thus, enhancing the international instrumentarium for health, and it has also prompted stronger role for national legislation on health. Notably, the Convention has elevated several traditionally challenging public health features to the level of international legal obligations. It has also revealed how the legal power of the international health instrument can be utilized in safeguarding the interests of health in the face of competing agendas and legal disputes at both the domestic and international levels. Lastly, the legal power of health instruments is associated with their potential impact not only on health but also beyond; the recently adopted Protocol to Eliminate Illicit Trade in Tobacco Products may best exemplify this matter. The first treaty experiences of the 21st century may provide important lessons for the role of legal instruments in addressing the unfolding challenges in global

  18. Delimiting coefficient alpha from internal consistency and unidimensionality

    NARCIS (Netherlands)

    Sijtsma, K.

    2015-01-01

    I discuss the contribution by Davenport, Davison, Liou, & Love (2015) in which they relate reliability represented by coefficient α to formal definitions of internal consistency and unidimensionality, both proposed by Cronbach (1951). I argue that coefficient α is a lower bound to reliability and

  19. International instruments and information exchange on incidents falling within the ITDB scope

    International Nuclear Information System (INIS)

    2010-01-01

    The responsibility for nuclear security rests entirely with each individual state. However,states need to work together to enhance collective nuclear security. There are international legal instruments that provide a strategic framework and a common platform for such cooperation. Among such legally binding security related instruments are: Convention on the physical protection of Nuclear materials, Convention on the early notification of nuclear accident and the International convention for the Suppression of acts of Nuclear Terrorism.

  20. Quality of life assessment in cosmetics: specificity and interest of the international BeautyQol instrument.

    Science.gov (United States)

    Beresniak, Ariel; Auray, Jean-Paul; Duru, Gérard; Aractingi, Selim; Krueger, Gerald G; Talarico, Sergio; Tsutani, Kiichiro; Dupont, Danielle; de Linares, Yolaine

    2015-09-01

    The wide use of cosmetics and their perceived benefits upon well-being imply objective descriptions of their effects upon the different dimensions contributing to the quality of life (QoL). Such a goal pleas for using relevant and validated scientific instruments with robust measurement methods. This paper discusses the interest of the new validated questionnaire BeautyQoL specifically designed to assess the effect of cosmetic products on physical appearance and QoL. After conducting a review of skin appearance and QoL, three phases of the international codevelopment have been carried out in the following sequence: semi-directed interviews (Phase 1), acceptability study (Phase 2), and validation study (Phase 3). Data collection and validation process have been carried out in 16 languages. This review confirms that QoL instruments developed in dermatology are not suitable to assess cosmetic products, mainly because of their lack of sensitivity. General acceptability of BeautyQol was very good. Forty-two questions have been structured in five dimensions that explained 76.7% of the total variance: Social Life, Self-confidence, Mood, Vitality, and Attractiveness. Cronbach's alpha coefficients are between 0.932 and 0.978, confirming the good internal consistency of the results. The BeautyQol questionnaire is the first international instrument specific to cosmetic products and physical appearance that has been validated in 16 languages and could be used in a number of clinical trials and descriptive studies to demonstrate the added value of these products on the QoL. © 2015 Wiley Periodicals, Inc.

  1. Factor structure and internal consistency of the 12-item General Health Questionnaire (GHQ-12 and the Subjective Vitality Scale (VS, and the relationship between them: a study from France

    Directory of Open Access Journals (Sweden)

    Ismaïl Amany

    2009-03-01

    Full Text Available Abstract Background The objectives of this study were to test the factor structure and internal consistency of the 12-item General Health Questionnaire (GHQ-12 and the Subjective Vitality Scale (VS in elderly French people, and to test the relationship between these two questionnaires. Methods Using a standard 'forward-backward' translation procedure, the English language versions of the two instruments (i.e. the 12-item General Health Questionnaire and the Subjective Vitality Scale were translated into French. A sample of adults aged 58–72 years then completed both questionnaires. Internal consistency was assessed by Cronbach's alpha coefficient. The factor structures of the two instruments were extracted by confirmatory factor analysis (CFA. Finally, the relationship between the two instruments was assessed by correlation analysis. Results In all, 217 elderly adults participated in the study. The mean age of the respondents was 61.7 (SD = 6.2 years. The mean GHQ-12 score was 17.4 (SD = 8.0, and analysis showed satisfactory internal consistency (Cronbach's alpha coefficient = 0.78. The mean VS score was 22.4 (SD = 7.4 and its internal consistency was found to be good (Cronbach's alpha coefficient = 0.83. While CFA showed that the VS was uni-dimensional, analysis for the GHQ-12 demonstrated a good fit not only to the two-factor model (positive vs. negative items but also to a three-factor model. As expected, there was a strong and significant negative correlation between the GHQ-12 and the VS (r = -0.71, P Conclusion The results showed that the French versions of the 12-item General Health Questionnaire (GHQ-12 and the Subjective Vitality Scale (VS are reliable measures of psychological distress and vitality. They also confirm a significant negative correlation between these two instruments, lending support to their convergent validity in an elderly French population. The findings indicate that both measures have good structural

  2. Human dignity according to international instruments on human rights

    Directory of Open Access Journals (Sweden)

    José Pablo Alzina de Aguilar

    2011-01-01

    Full Text Available According to international instruments on human rights, the dignity of the human person is the foundation of human rights, and both human dignity and human rights are inherent to the human being, universal and inviolable. This understanding of human dignity is not a fruitless truism, but the solid foundation on which to build a world community under the rule of the new ius gentium: the International Law for Humankind. Moreover, it is the clue to answer many questions raised by the new world of globalization and of the exponential growth of international rules.Consequently, there is a need to a common doctrine on a notion of human dignity which will allow the implementation and adjudication of the aforementioned instruments, at the service of the human person and in conformity with the juridical conscience which they reflect. Philosophy of Law concepts which can be traced back to Aristotle provide that notion. According to these concepts, the demanding nature of “human dignity” sustains the notion of “legal personhood”, and both notions pertain to the realm of Law and Right, not of Morale and Values. Thus, human dignity and human rights are and must be, respectively, a basic principle and a necessary part of any Law system, including international law

  3. Selected nondestructive assay instrumentation for an international safeguards system at uranium enrichment plants

    International Nuclear Information System (INIS)

    Tape, J.W.; Baker, M.P.; Strittmatter, R.; Jain, M.; Evans, M.L.

    1979-01-01

    A selected set of nondestructive assay instruments for an international safeguards system at uranium enrichment plants is currently under development. These instruments are of three types: in-line enrichment meters for feed, product, and tails streams; area radiation monitors for direct detection of high-enriched uranium production, and an enrichment meter for spent alumina trap material. The current status of the development of each of these instruments is discussed, with supporting data, as well as the role each would play in a total international safeguards system. 5 figures

  4. Use of fuel reprocessing plant instrumentation for international safeguards

    International Nuclear Information System (INIS)

    Ayers, A.L.

    1977-01-01

    The International Atomic Energy Agency has a program for developing instrumentation to be used by safeguards inspectors at reprocessing facilities. These instruments have generally been individual pieces of equipment for improving the accuracy of existing measurement instrumentation or equipment to perform nondestructive assay on a selected basis. It is proposed that greater use be made of redundant plant instrumentation and data recovery systems that could augment plant instrumentation to verify the validity of plant measurements. Use of these methods for verfication must be proven as part of an operating plant before they can be relied upon for safeguards surveillance. Inspectors must be qualified in plant operations, or have ready access to those so qualified, if the integrity of the operation is to be properly assessed. There is an immediate need for the development and in-plant proof testing of an integrated gamma, passive neutron, and active neutron measurement system for drum quantities of radioactive trash. The primary safeguards effort should be limited to plutonium and highly enriched uranium

  5. Determining the Feasibility, Content Validity, and Internal Consistency of a Newly Developed Care Coordination Scale for People with Brain Injury

    Directory of Open Access Journals (Sweden)

    Brian P. Johnson

    2017-07-01

    Full Text Available Background: With the increasing complexity of care, people with disabilities and supportive significant others (SSO must often coordinate key aspects of their own care, but no validated scale currently exists to comprehensively characterize the activities done to manage and coordinate their care. Method: This study aimed to improve the feasibility, acceptability, and content validity of the Care and Service Coordination and Management (CASCAM scale and to test its internal consistency. Questionnaire items were administered to 23 individuals with acquired brain injury and 17 SSO. Results: Respondents confirmed content validity and that the instrument addresses important care coordination and management issues. The internal consistency of care coordination domains for medical/ rehabilitative and independent living needs for people with brain injury and their SSO ranged from α = .774 to .945. Conclusion: Care coordination activities by persons with disabilities, including brain injury, and their SSO are multifaceted but feasibly measurable and should be assessed to improve care.

  6. Psychometrics and the neuroscience of individual differences: Internal consistency limits between-subjects effects.

    Science.gov (United States)

    Hajcak, Greg; Meyer, Alexandria; Kotov, Roman

    2017-08-01

    In the clinical neuroscience literature, between-subjects differences in neural activity are presumed to reflect reliable measures-even though the psychometric properties of neural measures are almost never reported. The current article focuses on the critical importance of assessing and reporting internal consistency reliability-the homogeneity of "items" that comprise a neural "score." We demonstrate how variability in the internal consistency of neural measures limits between-subjects (i.e., individual differences) effects. To this end, we utilize error-related brain activity (i.e., the error-related negativity or ERN) in both healthy and generalized anxiety disorder (GAD) participants to demonstrate options for psychometric analyses of neural measures; we examine between-groups differences in internal consistency, between-groups effect sizes, and between-groups discriminability (i.e., ROC analyses)-all as a function of increasing items (i.e., number of trials). Overall, internal consistency should be used to inform experimental design and the choice of neural measures in individual differences research. The internal consistency of neural measures is necessary for interpreting results and guiding progress in clinical neuroscience-and should be routinely reported in all individual differences studies. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  7. An international comparison of surface texture parameters quantification on polymer artefacts using optical instruments

    DEFF Research Database (Denmark)

    Tosello, Guido; Haitjema, H.; Leach, R.K.

    2016-01-01

    An international comparison of optical instruments measuring polymer surfaces with arithmetic mean height values in the sub-micrometre range has been carried out. The comparison involved sixteen optical surface texture instruments (focus variation instruments, confocal microscopes and coherent...

  8. The Legal Strength of International Health Instruments - What It Brings to Global Health Governance?

    Science.gov (United States)

    Nikogosian, Haik; Kickbusch, Ilona

    2016-09-04

    Public health instruments have been under constant development and renewal for decades. International legal instruments, with their binding character and strength, have a special place in this development. The start of the 21st century saw, in particular, the birth of the first World Health Organization (WHO)-era health treaties - the WHO Framework Convention on Tobacco Control (WHO FCTC) and its first Protocol. The authors analyze the potential impact of these instruments on global health governance and public health, beyond the traditional view of their impact on tobacco control. Overall, the very fact that globally binding treaties in modern-era health were feasible has accelerated the debate and expectations for an expanded role of international legal regimes in public health. The impact of treaties has also been notable in global health architecture as the novel instruments required novel institutions to govern their implementation. The legal power of the WHO FCTC has enabled rapid adoption of further instruments to promote its implementation, thus, enhancing the international instrumentarium for health, and it has also prompted stronger role for national legislation on health. Notably, the Convention has elevated several traditionally challenging public health features to the level of international legal obligations. It has also revealed how the legal power of the international health instrument can be utilized in safeguarding the interests of health in the face of competing agendas and legal disputes at both the domestic and international levels. Lastly, the legal power of health instruments is associated with their potential impact not only on health but also beyond; the recently adopted Protocol to Eliminate Illicit Trade in Tobacco Products may best exemplify this matter. The first treaty experiences of the 21st century may provide important lessons for the role of legal instruments in addressing the unfolding challenges in global health. © 2016 The

  9. Adopting New International Health Instruments - What Can We Learn From the FCTC? Comment on "The Legal Strength of International Health Instruments - What It Brings to Global Health Governance?"

    Science.gov (United States)

    Hesselman, Marlies; Toebes, Brigit

    2017-07-15

    This Commentary forms a response to Nikogosian's and Kickbusch's forward-looking perspective about the legal strength of international health instruments. Building on their arguments, in this commentary we consider what we can learn from the Framework Convention on Tobacco Control (FCTC) for the adoption of new legal international health instruments. © 2018 The Author(s); Published by Kerman University of Medical Sciences. This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  10. International economic association on production of nuclear instrumentation - ''INTERINSTRUMENT''

    International Nuclear Information System (INIS)

    Twardon, Z.

    1979-01-01

    History of establishment and development of the International economic association ''Interinstrument'' is stated. Structure of the Association is given and directions of its activity, as well as structure of its budget. List is given of organizations, performing works according to the agreements with the Association. Main directions are stated of activity of the Association in the field of specialization of production of items of nuclear equipment; co-ordination of activity in the sphere of foreign trade; information about new instruments. Activity is stated of the branch offices of the Association, engaged in maintenance of instruments and nuclear equipment [ru

  11. Differentiated sales and vehicles taxes. An assessment of instruments for the internalization of external costs of transport

    International Nuclear Information System (INIS)

    Schol, E.

    1995-12-01

    The level of differentiation of the sales and annual vehicle taxes is based on the avoidance costs of noise and air pollution caused by transportation. The assessment is made on economic, ecological, technical and political criteria. The basic assumption of this report is that a system of differentiated sales and annual vehicle taxes for passenger cars will be an additional instrument to an energy/CO 2 tax (or levy). The reason is that due to the far reaching characteristics, the incentives for innovation and the fact that fuel taxes are relatively easy to implement, the core of any internalization strategy at an international level should consist of a taxation on fuel. In this report the discussion of instruments is at the European Community level. On the base of this preliminary research it can be concluded that differentiated sales and annual vehicle taxes have no strong negative impacts, but also have not many strong positive impacts. The instruments will not lead to strong positive impacts on the environment. One of the reasons is that both tax systems are related to vehicle ownership and not to vehicle use. There is a stronger relationship between vehicle use and emissions than between vehicle ownership and emissions. However, the instruments probably are technically as well as politically feasible and will give an incentive for the development and sale of cleaner and more quiet vehicles within the European Union. 1 figs., 9 tabs., 22 refs

  12. Overview of intercalibration of satellite instruments

    Science.gov (United States)

    Chander, G.; Hewison, T.J.; Fox, N.; Wu, X.; Xiong, X.; Blackwell, W.J.

    2013-01-01

    Inter-calibration of satellite instruments is critical for detection and quantification of changes in the Earth’s environment, weather forecasting, understanding climate processes, and monitoring climate and land cover change. These applications use data from many satellites; for the data to be inter-operable, the instruments must be cross-calibrated. To meet the stringent needs of such applications requires that instruments provide reliable, accurate, and consistent measurements over time. Robust techniques are required to ensure that observations from different instruments can be normalized to a common scale that the community agrees on. The long-term reliability of this process needs to be sustained in accordance with established reference standards and best practices. Furthermore, establishing physical meaning to the information through robust Système International d'unités (SI) traceable Calibration and Validation (Cal/Val) is essential to fully understand the parameters under observation. The processes of calibration, correction, stability monitoring, and quality assurance need to be underpinned and evidenced by comparison with “peer instruments” and, ideally, highly calibrated in-orbit reference instruments. Inter-calibration between instruments is a central pillar of the Cal/Val strategies of many national and international satellite remote sensing organizations. Inter-calibration techniques as outlined in this paper not only provide a practical means of identifying and correcting relative biases in radiometric calibration between instruments but also enable potential data gaps between measurement records in a critical time series to be bridged. Use of a robust set of internationally agreed upon and coordinated inter-calibration techniques will lead to significant improvement in the consistency between satellite instruments and facilitate accurate monitoring of the Earth’s climate at uncertainty levels needed to detect and attribute the mechanisms

  13. On the internal consistency of the term structure of forecasts of housing starts

    DEFF Research Database (Denmark)

    Pierdzioch, C.; Rulke, J. C.; Stadtmann, G.

    2013-01-01

    We use the term structure of forecasts of housing starts to test for rationality of forecasts. Our test is based on the idea that short-term and long-term forecasts should be internally consistent. We test the internal consistency of forecasts using data for Australia, Canada, Japan and the United...

  14. Nurses' knowledge and attitudes towards aged sexuality: validity and internal consistency of the Dutch version of the Aging Sexual Knowledge and Attitudes Scale.

    Science.gov (United States)

    Mahieu, Lieslot; de Casterlé, Bernadette Dierckx; Van Elssen, Kim; Gastmans, Chris

    2013-11-01

    This paper reports a study testing the content and face validity and internal consistency of the Dutch version of the Aging Sexual Knowledge and Attitudes Scale. The ability of older residents to sexually express themselves is known to be influenced by the knowledge and attitudes of nursing home staff towards later-life sexuality. Although the Aging Sexual Knowledge and Attitudes Scale is a widely used instrument to measure this, there is no validated, Dutch translation available. Instrument development. Following a standard forward/backward translation into Dutch, the scale was further adapted for use in Flemish nursing home settings. Content and face validity and user-friendliness were assessed. The psychometric properties were determined by means of an exploratory study. Data were collected from March-April 2011 at eight Flemish nursing homes. Reliability was assessed using internal consistency and item-total correlations. Both subscales of the Flemish adaptation showed acceptable content validity. The face validity and user-friendliness were deemed favourable with hardly any remarks given by the expert panel. The Cronbach's α was 0.80 and 0.88 for the knowledge and attitude subscales, respectively. The item-total correlations ranged from 0.21-0.48 for the knowledge section and from 0.09-0.68 for the attitude subscale. We conclude from our study that the Dutch version of the scale has acceptable to good psychometric properties. The Flemish adaptation therefore seems to be a valuable instrument for studying nursing staff's knowledge and attitudes towards aged sexuality in Flanders. © 2013 Blackwell Publishing Ltd.

  15. Consistency of policy instruments. How the EU could move to a -30% greenhouse gas reduction target

    Energy Technology Data Exchange (ETDEWEB)

    Hoehne, N.; Hagemann, M.; Moltmann, S.; Escalante, D. [Ecofys Germany, Berlin (Germany)

    2011-04-15

    The report provides options for how to achieve a 30% reduction in greenhouse gas emissions, in the EU, from 1990 to 2020. The EU has agreed a set of goals (objectives) and related instruments for 2020. The most significant objectives are the 20% or 30% reduction of greenhouse gases (all emissions, both within and outside the Emissions Trading System), the 20% improvement of energy efficiency and the 20% of renewable energy use by 2020. The stringency of the instruments used to reach these goals, must be set carefully to ensure overall consistency. Particularly after the economic crisis of 2008/2009, the Climate and Energy Package has to be 'tuned' again to be fully consistent, e.g. fast take up of renewable energy and fewer emissions due to the recession may cause an over-allocation in the EU-ETS.

  16. Cross- cultural validation of the Brazilian Portuguese version of the Social Phobia Inventory (SPIN): study of the items and internal consistency.

    Science.gov (United States)

    Osório, Flávia de Lima; Crippa, José Alexandre S; Loureiro, Sonia Regina

    2009-03-01

    The objective of the present study was to carry out the cross- cultural validation for Brazilian Portuguese of the Social Phobia Inventory, an instrument for the evaluation of fear, avoidance and physiological symptoms associated with social anxiety disorder. The process of translation and adaptation involved four bilingual professionals, appreciation and approval of the back- translation by the authors of the original scale, a pilot study with 30 Brazilian university students, and appreciation by raters who confirmed the face validity of the Portuguese version, which was named ' Inventário de Fobia Social' . As part of the psychometric study of the Social Phobia Inventory, analysis of the items and evaluation of the internal consistency of the instrument were performed in a study conducted on 2314 university students. The results demonstrated that item 11, related to the fear of public speaking, was the most frequently scored item. The correlation of the items with the total score was quite adequate, ranging from 0.44 to 0.71, as was the internal consistency, which ranged from 0.71 to 0.90. The authors conclude that the Brazilian Portuguese version of the Social Phobia Inventory proved to be adequate regarding the psychometric properties initially studied, with qualities quite close to those of the original study. Studies that will evaluate the remaining indicators of validity of the Social Phobia Inventory in clinical and non-clinical samples are considered to be opportune and necessary.

  17. Development of international standards for instrumentation used for detection of illicit trafficking of radioactive material

    International Nuclear Information System (INIS)

    Voytchev, M.; Chiaro, P.; Radev, R.

    2006-01-01

    Subcommittee 45 B 'Radiation Protection Instrumentation' of the International Electrotechnical Commission (I.E.C.) is charged with the development of international standards for instrumentation used for monitoring of illicit trafficking of radioactive material through international boarders and territories, as well as inside countries. Currently three I.E.C. standards are in advanced stages of development. They are expected to be approved and published in 2006-2007. The international participation and the main characteristics of the following three standards are discussed and presented: I.E.C. 62327 'Hand-held Instruments for the Detection and Identification of Radionuclides and Additionally for the Indication of Ambient Dose Equivalent Rate from Photon Radiation', I.E.C. 62401 'Alarming Personal Radiation Devices for Detection of Illicit Trafficking of Radioactive Material' and I.E.C. 62244 'Installed Radiation Monitors for the Detection of Radioactive and Special Nuclear Materials at National Borders'

  18. Validity and internal consistency of a whiplash-specific disability measure

    NARCIS (Netherlands)

    Pinfold, Melanie; Niere, Ken R.; O'Leary, Elizabeth F.; Hoving, Jan Lucas; Green, Sally; Buchbinder, Rachelle

    2004-01-01

    STUDY DESIGN: Cross-sectional study of patients with whiplash-associated disorders investigating the internal consistency, factor structure, response rates, and presence of floor and ceiling effects of the Whiplash Disability Questionnaire (WDQ). OBJECTIVES: The aim of this study was to confirm the

  19. Development of international standards for instrumentation used for detection of illicit trafficking of radioactive material

    Energy Technology Data Exchange (ETDEWEB)

    Voytchev, M. [Institut de Radioprotection et de Surete Nucleaire (IRSN/DSU/SERAC/CTHIR), 91 - Gif sur Yvette (France); Chiaro, P. [Oak Ridge National Lab., TN (United States); Radev, R. [LLNL, Livermore, CA (United States)

    2006-07-01

    Subcommittee 45 B 'Radiation Protection Instrumentation' of the International Electrotechnical Commission (I.E.C.) is charged with the development of international standards for instrumentation used for monitoring of illicit trafficking of radioactive material through international boarders and territories, as well as inside countries. Currently three I.E.C. standards are in advanced stages of development. They are expected to be approved and published in 2006-2007. The international participation and the main characteristics of the following three standards are discussed and presented: I.E.C. 62327 'Hand-held Instruments for the Detection and Identification of Radionuclides and Additionally for the Indication of Ambient Dose Equivalent Rate from Photon Radiation', I.E.C. 62401 'Alarming Personal Radiation Devices for Detection of Illicit Trafficking of Radioactive Material' and I.E.C. 62244 'Installed Radiation Monitors for the Detection of Radioactive and Special Nuclear Materials at National Borders'.

  20. Validity and internal consistency of a whiplash-specific disability measure.

    Science.gov (United States)

    Pinfold, Melanie; Niere, Ken R; O'Leary, Elizabeth F; Hoving, Jan Lucas; Green, Sally; Buchbinder, Rachelle

    2004-02-01

    Cross-sectional study of patients with whiplash-associated disorders investigating the internal consistency, factor structure, response rates, and presence of floor and ceiling effects of the Whiplash Disability Questionnaire (WDQ). The aim of this study was to confirm the appropriateness of the proposed WDQ items. Whiplash injuries are a common cause of pain and disability after motor vehicle accidents. Neck disability questionnaires are often used in whiplash studies to assess neck pain but lack content validity for patients with whiplash-associated disorders. The newly developed WDQ measures functional limitations associated with whiplash injury and was designed after interviews with 83 patients with whiplash in a previous study. Researchers sought expert opinion on items of the WDQ, and items were then tested on a clinical whiplash population. Data were inspected to determine floor and ceiling effects, response rates, factor structure, and internal consistency. Packages of questionnaires were distributed to 55 clinicians, whose patients with whiplash completed and returned 101 questionnaires to researchers. No substantial floor or ceiling effects were identified on inspection of data. The overall floor effect was 12%, and the overall ceiling effect was 4%. Principal component analysis identified one broad factor that accounted for 65% of the variance in responses. Internal consistency was high; Cronbach's alpha = 0.96. Results of the study supported the retention of the 13 proposed items in a whiplash-specific disability questionnaire. Dependent on the results of further psychometric testing, the WDQ is likely to be an appropriate outcome measure for patients with whiplash.

  1. Internal consistency of a Spanish translation of the Francis Scale of Attitude Toward Christianity Short Form.

    Science.gov (United States)

    Campo-Arias, Adalberto; Oviedo, Heidi Celina; Díaz, Carmen Elena; Cogollo, Zuleima

    2006-12-01

    This study evaluated the internal consistency of a Spanish version of the short form of the Francis Scale of Attitude Toward Christianity based on responses of 405 Colombian adolescent students ages 13 to 17 years. This translated short-form version of the scale had an internal consistency of .80. This estimate indicates suitable internal consistency reliability for research use in this population.

  2. National environmental targets and international emission reduction instruments

    International Nuclear Information System (INIS)

    Morthorst, P.E.

    2003-01-01

    According to the agreed burden sharing within the European Union the overall EU emission reduction target as agreed by in the Kyoto protocol is converted into national greenhouse gas reduction-targets for each of the member states. In parallel with national emission reduction initiatives common EU policies for emission reductions are considered. Currently discussed is the introduction of a market for tradable permits for CO 2 -emissions to achieve emission reductions within the power industry and other energy intensive industries. In parallel with this markets for green certificates to deploy renewable energy technologies seem to be appearing in a number of countries, among these Denmark, Italy, Sweden, Belgium (Flanders), England and Australia. Although these national initiatives for a green certificate market are fairly different, they could be a starting point for establishing a common EU certificate market. But interactions between national targets for greenhouse gas emissions and these international instruments for emission reduction are not a trivial matter, especially not seen in relation to the possible contributions of these instruments in achieving national GHG-reduction targets. The paper is split into three parts all taking a liberalised power market as starting point: The first part discusses the consequences of a general deployment of renewable energy technologies, using planning initiatives or national promotion schemes (feed-in tariffs). In the second part an international green certificate market is introduced into the liberalised power market context, substituting other national promotion schemes. Finally, in the third part a combination of an international green certificate market (TGC) and an international emission-trading scheme for CO 2 is analysed within the liberalised international power market set-up. The main conclusion is that neither the use of national renewable support schemes nor the introduction of a TGC-market into a liberalised

  3. [Factor analysis and internal consistency of pedagogical practices questionnaire among health care teachers].

    Science.gov (United States)

    Pérez V, Cristhian; Vaccarezza G, Giulietta; Aguilar A, César; Coloma N, Katherine; Salgado F, Horacio; Baquedano R, Marjorie; Chavarría R, Carla; Bastías V, Nancy

    2016-06-01

    Teaching practice is one of the most complex topics of the training process in medicine and other health care careers. The Teaching Practices Questionnaire (TPQ) evaluates teaching skills. To assess the factor structure and internal consistency of the Spanish version of the TPP among health care teachers. The TPQ was answered by 315 university teachers from 13 of the 15 administrative Chilean regions, who were selected through a non-probabilistic volunteer sampling. The internal consistency of TPP factors was calculated and the correlation between them was analyzed. Six factors were identified: Student-centered teaching, Teaching planning, Assessment process, Dialogue relationship, Teacher-centered teaching and Use of technological resources. They had Cronbach alphas ranging from 0.60 to 0.85. The factorial structure of TPQ differentiates the most important functions of teaching. It also shows a theoretical consistency and a practical relevance to perform a diagnosis and continuous evaluation of teaching practices. Additionally, it has an adequate internal consistency. Thus, TPQ is valid and reliable to evaluate pedagogical practices in health care careers.

  4. Legal Aspects of Radioactive Waste Management: Relevant International Legal Instruments

    International Nuclear Information System (INIS)

    Wetherall, Anthony; Robin, Isabelle

    2014-01-01

    The responsible use of nuclear technology requires the safe and environmentally sound management of radioactive waste, for which countries need to have stringent technical, administrative and legal measures in place. The legal aspects of radioactive waste management can be found in a wide variety of legally binding and non-binding international instruments. This overview focuses on the most relevant ones, in particular those on nuclear safety, security, safeguards and civil liability for nuclear damage. It also identifies relevant regional instruments concerning environmental matters, in particular, with regard to strategic environmental assessments (SEAs), environmental impact assessments (EIAs), public access to information and participation in decision-making, as well as access to justice

  5. Internal consistency and content validity of a questionnaire aimed to assess the stages of behavioral lifestyle changes in Colombian schoolchildren: The Fuprecol study

    Directory of Open Access Journals (Sweden)

    Yasmira CARRILLO-BERNATE

    Full Text Available ABSTRACT Objective To assess internal consistency and content validity of a questionnaire aimed to assess the stages of Behavioural Lifestyle Changes in a sample of school-aged children and adolescents aged 9 to 17 years-old. Methods This validation study involved 675 schoolchildren from three official school in the city of Bogota, Colombia. A self-administered questionnaire called Behavioural Lifestyle Changes has been designed to explore stages of change regarding to physical activity/exercise, fruit and vegetable consumption, alcohol abuse, tobacco use, and drug abuse. Cronbach-α, Kappa index and exploratory factor analysis were used for evaluating the internal consistency and validity of content, respectively. Results The study population consisted of 51.1% males and the participants’ average age was 12.7±2.4 years-old. Behavioural Lifestyle Changes scored 0.720 (range 0.691 to 0.730 on the Cronbach α and intra-observer reproducibility was good (Kappa=0.71. Exploratory factor analysis determined two factors (factor 1: physical activity/exercise, fruit and vegetable consumption, and factor 2: alcohol abuse tobacco use and drug abuse, explaining 67.78% of variance by the items and six interactions χ2/gL=11649.833; p<0.001. Conclusion Behavioural Lifestyle Changes Questionnaire was seen to have suitable internal consistency and validity. This instrument can be recommended, mainly within the context of primary attention for studying the stages involved in the lifestyle behavioural changes model on a school-based population.

  6. [Validity and internal consistency of the Maslach Burnout Inventory in Dental Students from Cartagena, Colombia].

    Science.gov (United States)

    Simancas-Pallares, Miguel Angel; Fortich Mesa, Natalia; González Martínez, Farith Damián

    To determine the internal consistency and content validity of the Maslach Burnout Inventory-Student Survey (MBI-SS) in dental students from Cartagena, Colombia. Scale validation study in 886 dental students from Cartagena, Colombia. Factor structure was determined through exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). Internal consistency was measured using the Cronbach's alpha coefficient. Analyses were performed using the Stata v.13.2 for Windows (Statacorp., USA) and Mplus v.7.31 for Windows (Muthén & Muthén, USA) software. Internal consistency was α=.806. The factor structure showed three that accounted for the 56.6% of the variance. CFA revealed: χ 2 =926.036; df=85; RMSEA=.106 (90%CI, .100-.112); CFI=.947; TLI=.934. The MBI showed an adequate internal consistency and a factor structure being consistent with the original proposed structure with a poor fit, which does not reflect adequate content validity in this sample. Copyright © 2016 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  7. Inter-rater and test-retest reliability, internal consistency, and factorial structure of the instrument for forensic treatment evaluation

    NARCIS (Netherlands)

    Schuringa, E.; Spreen, M.; Bogaerts, S.

    2014-01-01

    In this study, the Instrument for Forensic Treatment Evaluation (IFTE) is introduced. The IFTE includes 14 dynamic items of the risk assessment scheme HKT-R and eight items specifically related to the treatment of forensic psychiatric patients. The items are divided over three factors: protective

  8. Adaptation and testing of psychosocial assessment instruments for cross-cultural use: an example from the Thailand Burma border.

    Science.gov (United States)

    Haroz, Emily E; Bass, Judith K; Lee, Catherine; Murray, Laura K; Robinson, Courtland; Bolton, Paul

    2014-01-01

    The purpose of this study was to develop valid and reliable instruments to assess priority psychosocial problems and functioning among adult survivors of systematic violence from Burma living in Thailand. The process involved four steps: 1) instrument drafting and piloting; 2) reliability and validity testing; 3) instrument revision; and 4) retesting revised instrument. A total of N = 158 interviews were completed. Overall subscales showed good internal consistency (0.73-0.92) and satisfactory combined test-retest/inter rater reliability (0.63-0.84). Criterion validity, was not demonstrated for any scale. The alcohol and functioning scales underperformed and were revised (step 3) and retested (step 4). Upon retesting, the function scale showed good internal consistency reliability (0.91-0.92), and the alcohol scale showed acceptable internal consistency (0.79) and strong test-retest/inter-rater reliability (0.86-0.89). This paper describes the importance and process of adaptation and testing, illustrated by the experiences and results for selected instruments in this population.

  9. Internal Consistency and Convergent Validity of the Klontz Money Behavior Inventory (KMBI

    Directory of Open Access Journals (Sweden)

    Colby D. Taylor

    2015-12-01

    Full Text Available The Klontz Money Behavior Inventory (KMBI is a standalone, multi-scale measure than can screen for the presence of eight distinct money disorders. Given the well-established relationship between mental health and financial behaviors, results from the KMBI can be used to inform both mental health care professionals and financial planners. The present study examined the internal consistency and convergent validity of the KMBI, through comparison with similar measures, among a sample of college students (n = 232. Results indicate that the KMBI demonstrates acceptable internal consistency reliability and some convergence for most subscales when compared to other analogous measures. These findings highlight a need for literature and assessments to identify and describe disordered money behaviors.

  10. Online self-report questionnaire on computer work-related exposure (OSCWE): validity and internal consistency.

    Science.gov (United States)

    Mekhora, Keerin; Jalayondeja, Wattana; Jalayondeja, Chutima; Bhuanantanondh, Petcharatana; Dusadiisariyavong, Asadang; Upiriyasakul, Rujiret; Anuraktam, Khajornyod

    2014-07-01

    To develop an online, self-report questionnaire on computer work-related exposure (OSCWE) and to determine the internal consistency, face and content validity of the questionnaire. The online, self-report questionnaire was developed to determine the risk factors related to musculoskeletal disorders in computer users. It comprised five domains: personal, work-related, work environment, physical health and psychosocial factors. The questionnaire's content was validated by an occupational medical doctor and three physical therapy lecturers involved in ergonomic teaching. Twenty-five lay people examined the feasibility of computer-administered and the user-friendly language. The item correlation in each domain was analyzed by the internal consistency (Cronbach's alpha; alpha). The content of the questionnaire was considered congruent with the testing purposes. Eight hundred and thirty-five computer users at the PTT Exploration and Production Public Company Limited registered to the online self-report questionnaire. The internal consistency of the five domains was: personal (alpha = 0.58), work-related (alpha = 0.348), work environment (alpha = 0.72), physical health (alpha = 0.68) and psychosocial factor (alpha = 0.93). The findings suggested that the OSCWE had acceptable internal consistency for work environment and psychosocial factors. The OSCWE is available to use in population-based survey research among computer office workers.

  11. Development of an instrument to measure student attitudes toward science fairs

    Science.gov (United States)

    Huddleston, Claudia A.

    Science fairs are woven into the very fabric of science instruction in the United States and in other countries. Even though thousands of students participate in science fairs every year, no instrument to measure student attitudes toward partaking in this hands-on learning experience has been fully developed and available for school administrators and teachers to assess the perceived value that current students attribute to participation in science fairs. Therefore, the purpose of this study was to continue the development and refinement of an instrument that measured student attitudes towards science fairs based on an unpublished instrument created by Michael (2005). The instrument developed and tested using 110 students at two different middle schools in southwest Virginia. The instrument consisted of 45 questions. After applying a principal component factor analysis, the instrument was reduced to two domains, enjoyment and value. The internal consistency of the instrument was calculated using Cronbach's alpha and showed good internal consistency of .89 between the two domains. Further analysis was conducted using a Pearson product-moment test and showed a significant positive correlation between enjoyment and value (r = .78). Demographic information was explored concerning the domains using a series of statistical tests, and results revealed no significant differences among race and science fair category. However, a significant difference was found among gender and students who won awards and those who did not. The conclusion was that further development and refinement of the instrument should be conducted.

  12. Psychometrics of an internalized homophobia instrument for men.

    Science.gov (United States)

    Theodore, John L; Shidlo, Ariel; Zemon, Vance; Foley, Frederick W; Dorfman, David; Dahlman, Karen L; Hamid, Sahira

    2013-01-01

    The Multi-Axial Gay Men's Inventory-Men's Short Version (MAGI-MSV) assesses internalized homophobia via 20 items and 3 dimensions. This study extended the psychometric examination of the MAGI-MSV. The instrument was administered to 228 ethnically diverse HIV-negative gay men seeking counseling in New York City (mean age = 35, age range = 16-70). Following principal axis factoring and parallel analyses, 4 factors emerged and 14 items were retained. The descriptive labels for factors included gay self-assurance and worth, public appearance of homosexuality, and impact of HIV/AIDS on homosexuality. The new, fourth factor was named maladaptive measures to eliminate homosexuality.

  13. New instruments in spatial planning : an international perspective on non-financial compensation

    NARCIS (Netherlands)

    Janssen-Jansen, L.; Spaans, M.; van der Veen, M.

    2008-01-01

    "New Instruments in Spatial Planning" addresses the topic of transferring development opportunities between areas in planning practice by a debate between academics, lawyers and planning practitioners at an international planning symposium in Annapolis, MD, USA and the Van Doorne-Habiforum

  14. Reliability, Dimensionality, and Internal Consistency as Defined by Cronbach: Distinct Albeit Related Concepts

    Science.gov (United States)

    Davenport, Ernest C.; Davison, Mark L.; Liou, Pey-Yan; Love, Quintin U.

    2015-01-01

    This article uses definitions provided by Cronbach in his seminal paper for coefficient a to show the concepts of reliability, dimensionality, and internal consistency are distinct but interrelated. The article begins with a critique of the definition of reliability and then explores mathematical properties of Cronbach's a. Internal consistency…

  15. Development of an international standard on instruments setpoints based on ISA S67.04 - 1994

    International Nuclear Information System (INIS)

    Quinn, E.L.

    1996-01-01

    This is a summary of the application for and development of an international standard on instrument setpoints, based on the Instrument Society of America (ISA) Standard S67.04 - 1994. The forum this new standard was proposed in is the International Electrotechnique Commission (IEC), based in Geneva, Switzerland, which is the international commission which oversees electrical and instrumentation standards for all applications around the world. The Instrument Society of America (ISA) is a United States based Society for the advancement of instrumentation and controls related science and technology and has 30,000 members. A division within the ISA is the Standard and Practices board which has over 5000 members actively involved in standards development and approval. In 1994, the ISA SP67, Nuclear Power Plant Standards Committee authorized that the IEC be approached to develop and issue an IEC standard on Instrument Setpoints. This application was formally submitted in January, 1995 to the IEC and approved for ballot to member countries in June, 1995. Approval for standard development by IEC was received in October, 1995 and the first draft vas issued in February, 1996, and is currently under review by the IEC working group. It is very important to focus on the approach that the U.S. and other countries are taking toward development of IEC standards that can apply to all nuclear instrumentation applications around the world. By referencing IEC standards in design specification, vendors can be solicited from many different countries, thereby ensuring that the highest quality products can be used. This also offsets the need to specify individual standards in the specification, based on the country that each vendor solicited, represents. In summary, this standard development process, with support from the American National Standards Institute (ANSI) will assist U.S. suppliers in competing in the global market for products and services into the next century. (author)

  16. Internal Consistency, Retest Reliability, and their Implications For Personality Scale Validity

    Science.gov (United States)

    McCrae, Robert R.; Kurtz, John E.; Yamagata, Shinji; Terracciano, Antonio

    2010-01-01

    We examined data (N = 34,108) on the differential reliability and validity of facet scales from the NEO Inventories. We evaluated the extent to which (a) psychometric properties of facet scales are generalizable across ages, cultures, and methods of measurement; and (b) validity criteria are associated with different forms of reliability. Composite estimates of facet scale stability, heritability, and cross-observer validity were broadly generalizable. Two estimates of retest reliability were independent predictors of the three validity criteria; none of three estimates of internal consistency was. Available evidence suggests the same pattern of results for other personality inventories. Internal consistency of scales can be useful as a check on data quality, but appears to be of limited utility for evaluating the potential validity of developed scales, and it should not be used as a substitute for retest reliability. Further research on the nature and determinants of retest reliability is needed. PMID:20435807

  17. Internal consistency reliability and validity of the Arabic translation of the Mathematics Teaching Efficacy Beliefs Instrument.

    Science.gov (United States)

    Alkhateeb, Haitham M

    2004-06-01

    The Arabic translation of the Mathematics Teaching Efficacy Beliefs was completed by 144 undergraduate students (M age=20.6) in Jordan. The findings support the internal reliability of the Arabic translation of the Mathematics Teaching Efficacy Beliefs as well as its construct validity.

  18. A diagnostic test for apraxia in stroke patients: internal consistency and diagnostic value.

    NARCIS (Netherlands)

    Heugten, C.M. van; Dekker, J.; Deelman, B.G.; Stehmann-Saris, F.C.; Kinebanian, A.

    1999-01-01

    The internal consistency and the diagnostic value of a test for apraxia in patients having had a stroke are presented. Results indicate that the items of the test form a strong and consistent scale: Cronbach's alpha as well as the results of a Mokken scale analysis present good reliability and good

  19. Climate protection after Copenhagen. International instruments and national implementation. Proceedings; Klimaschutz nach Kopenhagen. Internationale Instrumente und nationale Umsetzung. Tagungsband

    Energy Technology Data Exchange (ETDEWEB)

    Gundel, Joerg; Lange, Knut Werner (eds.)

    2011-07-01

    The publication contains the results of the First Bayreuth Energy Law Days on the subject of 'Climate Protection after Copenhagen'. Following the UN climate conference of December 2009, it presents the current state of discussion of the legal instruments of climate protection on an international, European and national level. (orig./RHM)

  20. Reliability of AOFAS diabetic foot questionnaire in Charcot arthropathy: stability, internal consistency, and measurable difference.

    Science.gov (United States)

    Dhawan, Vibhu; Spratt, Kevin F; Pinzur, Michael S; Baumhauer, Judith; Rudicel, Sally; Saltzman, Charles L

    2005-09-01

    The development of Charcot changes is known to be associated with a high rate of recurrent ulceration and amputation. Unfortunately, the effect of Charcot arthropathy on quality of life in diabetic patients has not been systematically studied because of a lack of a disease-specific instrument. The purpose of this study was to develop and test an instrument to evaluate the health-related quality of life of diabetic foot disease. Subjects diagnosed with Charcot arthropathy completed a patient self-administered questionnaire, and clinicians completed an accompanying observational survey. The patient self-administered questionnaire was organized into five general sections: demographics, general health, diabetes-related symptoms, comorbidities, and satisfaction. The scales measured the effect in six health domains: 1) general health, 2) care, 3) worry, 4) sleep, 5) emotion, and 6) physicality. The psychometric properties of the scales were evaluated and the summary scores for the Short-Form Health Survey (SF-36) were compared to published norms for other major medical illnesses. Of the 89 enrolled patients, 57 who completed the questionnaire on enrollment returned a second completed form at 3-month followup. Over the 3-month followup period most of the patients showed an improvement in the Eichenholtz staging. The internal consistency of most was moderate to high and, in general, the scale scores were stable over 3 months. However, several of the scales suffered from low-ceiling or high-floor effects. Patients with Charcot arthropathy had a much lower physical component score on enrollment than the reported norms for other disease conditions, including diabetes. Quality of life represents an important set of outcomes when evaluating the effectiveness of treatment for patients with Charcot arthropathy. This study represents an initial attempt to develop a standardized survey for use with this patient population. Further studies need to be done with larger groups of

  1. Escala de Autoestima de Rosenberg (EAR: validade fatorial e consistência interna Rosenberg Self-Esteem Scale (RSS: factorial validity and internal consistency

    Directory of Open Access Journals (Sweden)

    Juliana Burges Sbicigo

    2010-12-01

    Full Text Available O objetivo deste estudo foi investigar as propriedades psicométricas da Escala de Autoestima de Rosenberg (EAR para adolescentes. Participaram 4.757 adolescentes, com idades entre 14 e 18 anos (M=15,77; DP=1,22, de nove cidades brasileiras. Os participantes responderam a uma versão da EAR adaptada para o Brasil. A análise fatorial exploratória apontou uma estrutura bidimensional, com 51.4% da variância explicada, que foi sustentada pela análise fatorial confirmatória. As análises de consistência interna realizadas por meio do coeficiente alfa de Cronbach, confiabilidade composta e variância extraída indicaram bons valores de fidedignidade. Diferenças nos escores de autoestima em função do sexo e da idade não foram encontradas. Conclui-se que a EAR apresenta qualidades psicométricas satisfatórias, mostrando-se um instrumento confiável para medir autoestima em adolescentes brasileiros.The aim of this study was to investigate the psychometrics properties of the Rosenberg Self-Esteem Scale (RSS for adolescents. The sample was composed of 4.757 adolescents, with ages between 14 and 18 years old (M=15.77; SD=1.22 in nine Brazilian cities. Participants responded to an adapted version of the RSS for Brazil. Exploratory factorial analysis showed a bidimensional structure, with 51.4% of explained variance. This result was supported by confirmatory factor analysis. The internal consistency analysis by Cronbach alpha coefficient, composite reliability and extracted variance indicated good reliability. Differences in self-esteem for gender and age were not found. These findings show that RSS has satisfactory psychometric qualities and it's a reliable instrument to assess self-esteem in Brazilian adolescents.

  2. The internal consistency of the standard gamble: tests after adjusting for prospect theory.

    Science.gov (United States)

    Oliver, Adam

    2003-07-01

    This article reports a study that tests whether the internal consistency of the standard gamble can be improved upon by incorporating loss weighting and probability transformation parameters in the standard gamble valuation procedure. Five alternatives to the standard EU formulation are considered: (1) probability transformation within an EU framework; and, within a prospect theory framework, (2) loss weighting and full probability transformation, (3) no loss weighting and full probability transformation, (4) loss weighting and no probability transformation, and (5) loss weighting and partial probability transformation. Of the five alternatives, only the prospect theory formulation with loss weighting and no probability transformation offers an improvement in internal consistency over the standard EU valuation procedure.

  3. The Basic Design Report of the 40M SANS Instrument

    Energy Technology Data Exchange (ETDEWEB)

    Han, Young Soo; Lee, Chang Hee; Hwang, Dong Gil; Kim, Hak Rho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Tae Hwan; Choi, Sung Min [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2006-04-15

    The HANARO cold neutron research facility project was launched on July 1, 2003. A state of the art SANS instrument was selected as a top-priority instrument by an instrument selection committee, which consisted of domestic users and HANARO personnel. An instrument development team and an international and domestic instrument advisory team were formulated. The guide and the instrument simulation were performed using Vitess software and the optimum basic design was completed based on the simulation results and the international advisory team reviews. The optimum design of the guide for the 40M SANS instrument was completed and the optimum basic design of the 40M the SANS instrument was also completed based on the Vitess simulation results. The Q range of the instrument will cover from 0.0008 to 1.0 A-1 and the maximum flux at a sample position can reach about 5.5x10 7 n/cm2sec. The simulation results and the basic design product will be used for the detailed design and the construction of the SANS instrument. The simulation results could be applied to the development of the other instrument.

  4. Assessing motivation for work environment improvements: internal consistency, reliability and factorial structure.

    Science.gov (United States)

    Hedlund, Ann; Ateg, Mattias; Andersson, Ing-Marie; Rosén, Gunnar

    2010-04-01

    Workers' motivation to actively take part in improvements to the work environment is assumed to be important for the efficiency of investments for that purpose. That gives rise to the need for a tool to measure this motivation. A questionnaire to measure motivation for improvements to the work environment has been designed. Internal consistency and test-retest reliability of the domains of the questionnaire have been measured, and the factorial structure has been explored, from the answers of 113 employees. The internal consistency is high (0.94), as well as the correlation for the total score (0.84). Three factors are identified accounting for 61.6% of the total variance. The questionnaire can be a useful tool in improving intervention methods. The expectation is that the tool can be useful, particularly with the aim of improving efficiency of companies' investments for work environment improvements. Copyright 2010 Elsevier Ltd. All rights reserved.

  5. Studies on the consistency of internally taken contrast medium for pancreas CT

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Kishio; Mimura, Seiichi; Tahara, Seiji; Kitayama, Takuichi; Inamura, Keiji; Mikami, Yasutaka; Hashimoto, Keiji; Hiraki, Yoshio; Aono, Kaname

    1985-02-01

    A problem of Pancreatic CT scanning is the discrimination between the pancreas and the adjacent gastrointestinal tract. Generally we administer a dilution of gastrografin internally to make the discrimination. The degree of dilution has been decided by experience at each hospital. When the consistency of the contrast medium is low in density, an enhancement effect cannot be expected, but when the consistency is high, artifacts appear. We have experimented on the degree of the dilution and CT-No to decide the optimum consistency of gastrografin for the diagnosis of pancreatic disease. Statistical analysis of the results show the optimum dilution of gastrografin to be 1.5%.

  6. Adaptação transcultural e consistência interna do Early Trauma Inventory (ETI Early Trauma Inventory (ETI: cross-cultural adaptation and internal consistency

    Directory of Open Access Journals (Sweden)

    Marcelo Feijó de Mello

    2010-04-01

    Full Text Available As experiências traumáticas precoces são um fator de risco preditivo de problemas psicopatológicos futuros. O Early Trauma Inventory (ETI é um instrumento que avalia em indivíduos adultos experiências traumáticas ocorridas antes dos 18 anos de idade. Tal instrumento foi traduzido, transculturalmente adaptado e sua consistência interna foi avaliada. Vítimas de violência que preencheram os critérios de inclusão e exclusão foram submetidas a uma entrevista diagnóstica (SCID-I e ao ETI. Foram incluídos 91 pacientes com o transtorno do estresse pós-traumático (TEPT. O alfa de Cronbach nos diferentes domínios variou de 0,595-0,793, e o escore total foi de 0,878. A maior parte dos itens nos vários domínios, com exceção do abuso emocional, apresentou índices de correlação interitem entre 0,51-0,99. A versão adaptada foi útil tanto na clínica quanto na pesquisa. Apresentou boa consistência interna e na correlação interitem. O ETI é um instrumento válido, com boa consistência para se avaliar a presença de história de traumas precoces em indivíduos adultos.Early life stress is a strong predictor of future psychopathology during adulthood. The Early Trauma Inventory (ETI was developed to detect the presence and impact of traumatic experiences that occurred up to 18 years of age. The ETI was translated and cross-culturally adapted and had its consistency evaluated. Victims of violence that met the inclusion and exclusion criteria were submitted to SCID-I and ETI. Ninety-one patients with post-traumatic stress disorder (PTSD were included. Cronbach's alpha in the different domains varied from 0.595 to 0.793, and the total score was 0.878. Except for emotional abuse, most of the various domains displayed inter-item correlation rates of 0.51 to 0.99. The adapted version was useful for clinical and research purposes and showed good internal consistency and inter-item correlation. The ETI is a valid instrument with good

  7. Internal consistency of the CHAMPS physical activity questionnaire for Spanish speaking older adults.

    Science.gov (United States)

    Rosario, Martín G; Vázquez, Jenniffer M; Cruz, Wanda I; Ortiz, Alexis

    2008-09-01

    The Community Healthy Activities Model Program for Seniors (CHAMPS) is a physical activity monitoring questionnaire for people between 65 to 90 years old. This questionnaire has been previously translated to Spanish to be used in the Latin American population. To adapt the Spanish version of the CHAMPS questionnaire to Puerto Rico and assess its internal consistency. An external review committee adapted the existent Spanish version of the CHAMPS to be used in the Puerto Rican population. Three older adults participated in a second phase with the purpose of training the research team. After the second phase, 35 older adults participated in a third content adaptation phase. During the third phase, the preliminary Spanish version for Puerto Rico of the CHAMPS was given to the 35 participants to assess for clarity, vocabulary and understandability. Interviews to each participant in the third phase were carried out to obtain feedback and create a final Spanish version of the CHAMPS for Puerto Rico. After analyses of this phase, the external review committee prepared a final Spanish version of the CHAMPS for Puerto Rico. The final version was administered to 15 older adults (76 +/- 6.5 years) to assess the internal consistency by using Cronbach's Alpha analysis. The questionnaire showed a strong internal consistency of 0.76. The total time to answer the questionnaire was 17.4 minutes. The Spanish version of the CHAMPS questionnaire for Puerto Rico suggested being an easy to administer and consistent measurement tool to assess physical activity in older adults.

  8. Concurrent validation of CHIRP, a new instrument for measuring healthcare student attitudes towards interdisciplinary teamwork.

    Science.gov (United States)

    Hollar, David; Hobgood, Cherri; Foster, Beverly; Aleman, Marco; Sawning, Susan

    2012-01-01

    Positive attitudes towards teamwork among health care professionals are critical to patient safety. The purpose of this study is to describe the development and concurrent validation of a new instrument to measure attitudes towards healthcare teamwork that is generalizable across various populations of healthcare students. The Collaborative Healthcare Interdisciplinary Planning (CHIRP) scale was validated against the Readiness for Inter-Professional Learning Scale (RIPLS). Analyses included student (n = 266) demographics, ANOVA, internal consistency, factor analysis, and Rasch analysis. The two instruments correlated at r = .582. The CHIRP showed a multifactorial structure having excellent internal consistency (alpha = .850), with 25 of the 36 scale items loading onto a single Teamwork Attitudes factor. The RIPLS likewise had strong internal consistency (alpha = .796) and a three-factor structure, supporting previous studies of the instrument. However, Rasch analyses showed 14 (38.9%) of the 36 CHIRP items, but only four (21.1%) of the 19 RIPLS items remaining within the satisfactory standardized OUTFIT zone of 2.0 standard deviation units. We propose the 14 fitting items as a new, validated teamwork attitudes scale.

  9. Lateral Violence in Nursing Survey: Instrument Development and Validation

    Directory of Open Access Journals (Sweden)

    Lynne S. Nemeth

    2017-07-01

    Full Text Available An examination of the psychometric properties of the Lateral Violence in Nursing Survey (LVNS, an instrument previously developed to measure the perceived incidence and severity of lateral violence (LV in the nursing workplace, was carried out. Conceptual clustering and principal components analysis were used with survey responses from 663 registered nurses and ancillary nursing staff in a southeastern tertiary care medical center. Where appropriate, Cronbach’s alpha (α evaluated internal consistency. The prevalence/severity of lateral violence items constitute two distinct subscales (LV by self and others with Cronbach’s alpha of 0.74 and 0.86, respectively. The items asking about potential causes of LV are unidimensional and internally consistent (alpha = 0.77 but there is no conceptually coherent theme underlying the various causes. Respondents rating a potential LV cause as “major” scored higher on both prevalence/severity subscales than those rating it a “minor” cause or not a cause. Subsets of items on the LVNS are internally reliable, supporting construct validity. Revisions of the original LVNS instrument will improve its use in future work.

  10. 2nd International Conference on Measurement Instrumentation and Electronics

    International Nuclear Information System (INIS)

    2017-01-01

    Preface It is our great pleasure to welcome you to 2017 2nd International Conference on Measurement Instrumentation and Electronics which has been held in Prague, Czech Republic during June 9-11, 2017. ICMIE 2017 is dedicated to issues related to measurement instrumentation and electronics. The major goal and feature of the conference is to bring academic scientists, engineers, industry researchers together to exchange and share their experiences and research results, and discuss the practical challenges encountered and the solutions adopted. Professors from Czech Republic, Germany and Italy are invited to deliver keynote speeches regarding latest information in their respective expertise areas. It is a golden opportunity for the students, researchers and engineers to interact with the experts and specialists to get their advice or consultation on technical matters, teaching methods and strategies. These proceedings present a selection from papers submitted to the conference from universities, research institutes and industries. All of the papers were subjected to peer-review by conference committee members and international reviewers. The papers selected depended on their quality and their relevancy to the conference. The volume tends to present to the readers the recent advances in the field of computer and communication system, system design and measurement and control technology, power electronics and electrical engineering, materials science and engineering, power machinery and equipment maintenance, architectural design and project management, environmental analysis and detection etc. We would like to thank all the authors who have contributed to this volume and also to the organizing committee, reviewers, speakers, chairpersons, and all the conference participants for their support to ICMIE 2017. ICMIE 2017 Organizing Committee June 20th, 2017 (paper)

  11. Psychometric Evaluation of the D-Catch, an Instrument to Measure the Accuracy of Nursing Documentation.

    Science.gov (United States)

    D'Agostino, Fabio; Barbaranelli, Claudio; Paans, Wolter; Belsito, Romina; Juarez Vela, Raul; Alvaro, Rosaria; Vellone, Ercole

    2017-07-01

    To evaluate the psychometric properties of the D-Catch instrument. A cross-sectional methodological study. Validity and reliability were estimated with confirmatory factor analysis (CFA) and internal consistency and inter-rater reliability, respectively. A sample of 250 nursing documentations was selected. CFA showed the adequacy of a 1-factor model (chronologically descriptive accuracy) with an outlier item (nursing diagnosis accuracy). Internal consistency and inter-rater reliability were adequate. The D-Catch is a valid and reliable instrument for measuring the accuracy of nursing documentation. Caution is needed when measuring diagnostic accuracy since only one item measures this dimension. The D-Catch can be used as an indicator of the accuracy of nursing documentation and the quality of nursing care. © 2015 NANDA International, Inc.

  12. Development and Testing of Screen-Based and Psychometric Instruments for Assessing Resident Performance in an Operating Room Simulator

    Directory of Open Access Journals (Sweden)

    Richard R. McNeer

    2016-01-01

    Full Text Available Introduction. Medical simulators are used for assessing clinical skills and increasingly for testing hypotheses. We developed and tested an approach for assessing performance in anesthesia residents using screen-based simulation that ensures expert raters remain blinded to subject identity and experimental condition. Methods. Twenty anesthesia residents managed emergencies in an operating room simulator by logging actions through a custom graphical user interface. Two expert raters rated performance based on these entries using custom Global Rating Scale (GRS and Crisis Management Checklist (CMC instruments. Interrater reliability was measured by calculating intraclass correlation coefficients (ICC, and internal consistency of the instruments was assessed with Cronbach’s alpha. Agreement between GRS and CMC was measured using Spearman rank correlation (SRC. Results. Interrater agreement (GRS: ICC = 0.825, CMC: ICC = 0.878 and internal consistency (GRS: alpha = 0.838, CMC: alpha = 0.886 were good for both instruments. Subscale analysis indicated that several instrument items can be discarded. GRS and CMC scores were highly correlated (SRC = 0.948. Conclusions. In this pilot study, we demonstrated that screen-based simulation can allow blinded assessment of performance. GRS and CMC instruments demonstrated good rater agreement and internal consistency. We plan to further test construct validity of our instruments by measuring performance in our simulator as a function of training level.

  13. Tradução, adaptação e avaliação da consistência interna do Eating Behaviours and Body Image Test para uso com crianças do sexo feminino Translation, adaptation and internal consistency evaluation of the Eating Behaviours and Body Image Test for female children

    Directory of Open Access Journals (Sweden)

    Elizângela Moreira Careta Galindo

    2007-02-01

    Full Text Available Este trabalho tem por objetivo traduzir, adaptar e validar o Eating Behaviours and Body Image Test, para uso com crianças de uma cidade do interior do estado de São Paulo. Foram sujeitos do estudo 261 escolares do sexo feminino, na faixa etária de 9 a 12 anos. Por meio da análise fatorial, com rotação varimax avaliou-se a consistência interna do instrumento. Esta análise, realizada com o auxílio do programa Statistical Package for Social Sciences, versão 10.0, revelou dois fatores. Para o instrumento total a consistência interna foi adequada (coeficiente a de Cronbach: 0,89 e para os dois fatores (1 e 2 os valores de a também foram considerados satisfatórios (alfa=0,90 e alfa=0,80, respectivamente, mostrando, assim, que o Eating Behaviours and Body Image Test é útil para uma avaliação precoce, rastreando atitudes indicadoras de possíveis distúrbios no comportamento alimentar. Foram mantidas as características psicométricas do instrumento original.This study aimed to translate, adapt and validate the Eating Bahaviours and Body Image Test, to be used with children in a city in upstate São Paulo. Study subjects were 261 female students aging from 9 to 12 years. The internal consistency of the instrument was evaluated by means of factorial analysis with varimax rotation. This analysis was accomplished through Statistical Package for Social Sciences, version 10.0, revealing two factors. The internal consistency was adequate for the total instrument (Cronbach's alpha=0.89 and a values were also considered satisfactory for the two factors (1 and 2 (alpha=0.90 and alpha=0.80, respectively, which demonstrated that the Eating Bahaviours and Body Image Test is useful for an initial evaluation, tracing symptoms that indicate possible eating behavior disorders. The psychometric characteristics of the original instrument were maintained.

  14. Expanding the Reach of Participatory Risk Management: Testing an Online Decision-Aiding Framework for Informing Internally Consistent Choices.

    Science.gov (United States)

    Bessette, Douglas L; Campbell-Arvai, Victoria; Arvai, Joseph

    2016-05-01

    This article presents research aimed at developing and testing an online, multistakeholder decision-aiding framework for informing multiattribute risk management choices associated with energy development and climate change. The framework was designed to provide necessary background information and facilitate internally consistent choices, or choices that are in line with users' prioritized objectives. In order to test different components of the decision-aiding framework, a six-part, 2 × 2 × 2 factorial experiment was conducted, yielding eight treatment scenarios. The three factors included: (1) whether or not users could construct their own alternatives; (2) the level of detail regarding the composition of alternatives users would evaluate; and (3) the way in which a final choice between users' own constructed (or highest-ranked) portfolio and an internally consistent portfolio was presented. Participants' self-reports revealed the framework was easy to use and providing an opportunity to develop one's own risk-management alternatives (Factor 1) led to the highest knowledge gains. Empirical measures showed the internal consistency of users' decisions across all treatments to be lower than expected and confirmed that providing information about alternatives' composition (Factor 2) resulted in the least internally consistent choices. At the same time, those users who did not develop their own alternatives and were not shown detailed information about the composition of alternatives believed their choices to be the most internally consistent. These results raise concerns about how the amount of information provided and the ability to construct alternatives may inversely affect users' real and perceived internal consistency. © 2015 Society for Risk Analysis.

  15. Test - retest reliability of two instruments for measuring public attitudes towards persons with mental illness

    Directory of Open Access Journals (Sweden)

    Leufstadius Christel

    2011-01-01

    Full Text Available Abstract Background Research has identified stigmatization as a major threat to successful treatment of individuals with mental illness. As a consequence several anti-stigma campaigns have been carried out. The results have been discouraging and the field suffers from lack of evidence about interventions that work. There are few reports on psychometric data for instruments used to assess stigma, which thus complicates research efforts. The aim of the present study was to investigate test-retest reliability of the Swedish versions of the questionnaires: FABI and "Changing Minds" and to examine the internal consistency of the two instruments. Method Two instruments, fear and behavioural intentions (FABI and "Changing Minds", used in earlier studies on public attitudes towards persons with mental illness were translated into Swedish and completed by 51 nursing students on two occasions, with an interval of three weeks. Test-retest reliability was calculated by using weighted kappa coefficient and internal consistency using the Cronbach's alpha coefficient. Results Both instruments attain at best moderate test-retest reliability. For the Changing Minds questionnaire almost one fifth (17.9% of the items present poor test-retest reliability and the alpha coefficient for the subscales ranges between 0.19 - 0.46. All of the items in the FABI reach a fair or a moderate agreement between the test and retest, and the questionnaire displays a high internal consistency, alpha 0.80. Conclusions There is a need for development of psychometrically tested instruments within this field of research.

  16. SEQUenCE: a service user-centred quality of care instrument for mental health services.

    Science.gov (United States)

    Hester, Lorraine; O'Doherty, Lorna Jane; Schnittger, Rebecca; Skelly, Niamh; O'Donnell, Muireann; Butterly, Lisa; Browne, Robert; Frorath, Charlotte; Morgan, Craig; McLoughlin, Declan M; Fearon, Paul

    2015-08-01

    To develop a quality of care instrument that is grounded in the service user perspective and validate it in a mental health service. The instrument (SEQUenCE (SErvice user QUality of CarE)) was developed through analysis of focus group data and clinical practice guidelines, and refined through field-testing and psychometric analyses. All participants were attending an independent mental health service in Ireland. Participants had a diagnosis of bipolar affective disorder (BPAD) or a psychotic disorder. Twenty-nine service users participated in six focus group interviews. Seventy-one service users participated in field-testing: 10 judged the face validity of an initial 61-item instrument; 28 completed a revised 52-item instrument from which 12 items were removed following test-retest and convergent validity analyses; 33 completed the resulting 40-item instrument. Test-retest reliability, internal consistency and convergent validity of the instrument. The final instrument showed acceptable test-retest reliability at 5-7 days (r = 0.65; P Service Satisfaction Scale (r = 0.84, P internal consistency (Cronbach's alpha = 0.87). SEQUenCE is a valid, reliable scale that is grounded in the service user perspective and suitable for routine use. It may serve as a useful tool in individual care planning, service evaluation and research. The instrument was developed and validated with service users with a diagnosis of either BPAD or a psychotic disorder; it does not yet have established external validity for other diagnostic groups. © The Author 2015. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.

  17. THE ECONOMIC INSTRUMENTARY OF THE "SOFT POWER" IN THE INTERNATIONAL ECONOMIC RELATIONS

    Directory of Open Access Journals (Sweden)

    Zlatka Kushelieva

    2017-09-01

    Full Text Available "Soft power" is a complex instrument of international politics. It is an organized set of interactions and relationships predetermined to a large extent by the psychological element. Its core qualities are attraction, persuasion and legitimacy. The "soft power" acts in international relations through a complex instrumentation consisting of actions in the military, political, economic, cultural, sports, ideological, religious spheres, but all its manifestations must be supported by the economic instrument. To this end, many countries have set up special bodies. It is expected that "soft power" will be a major instrument of international politics in the coming epoch.

  18. The COSMIN checklist for assessing the methodological quality of studies on measurement properties of health status measurement instruments: an international Delphi study.

    Science.gov (United States)

    Mokkink, Lidwine B; Terwee, Caroline B; Patrick, Donald L; Alonso, Jordi; Stratford, Paul W; Knol, Dirk L; Bouter, Lex M; de Vet, Henrica C W

    2010-05-01

    Aim of the COSMIN study (COnsensus-based Standards for the selection of health status Measurement INstruments) was to develop a consensus-based checklist to evaluate the methodological quality of studies on measurement properties. We present the COSMIN checklist and the agreement of the panel on the items of the checklist. A four-round Delphi study was performed with international experts (psychologists, epidemiologists, statisticians and clinicians). Of the 91 invited experts, 57 agreed to participate (63%). Panel members were asked to rate their (dis)agreement with each proposal on a five-point scale. Consensus was considered to be reached when at least 67% of the panel members indicated 'agree' or 'strongly agree'. Consensus was reached on the inclusion of the following measurement properties: internal consistency, reliability, measurement error, content validity (including face validity), construct validity (including structural validity, hypotheses testing and cross-cultural validity), criterion validity, responsiveness, and interpretability. The latter was not considered a measurement property. The panel also reached consensus on how these properties should be assessed. The resulting COSMIN checklist could be useful when selecting a measurement instrument, peer-reviewing a manuscript, designing or reporting a study on measurement properties, or for educational purposes.

  19. [Validation of an instrument to measure food practices in Chilean families of school children aged 4-7 years].

    Science.gov (United States)

    Lera, Lydia; Salinas, Judith; Fretes, Gabriela; Vio, Fernando

    2013-11-01

    It is necessary to assess family food habits in school children to cope with infant obesity. Designing and validation of an instrument to measure food habits and food knowledge in Chilean preschool and school families based on dietary guidelines. A pilot study in 30 preschool and school-age parents was carried-out. A questionnaire to measure food habits and food knowledge in parents was elaborated by researchers considering an expert group opinion. This questionnaire was applied twice with a 15 days interval, evaluating temporal stability, internal consistency and inter-personal agreement. Afterwards, the questionnaire was applied to 59 parents calculating the internal consistency of the instrument. The questionnaire had 55 questions in 4 sections. The instrument had questions about food and nutrition information about the families. A good inter-personal agreement resulted for almost all the questions about food and nutrition information (0.5-1.0). The correlation between the first and second test (test-retest) was high (0.6-1.0), as well as the internal consistency (0.75). In the section about frequency consumption in parents and children food consumption at home and school there was a high internal consistency for the two observers (0.85-0.92 and 0.87-0.90). The instrument is valid and useful to be utilized in preschool and school families intervened with nutrition education, and this methodology can be replied in other studies. Copyright AULA MEDICA EDICIONES 2013. Published by AULA MEDICA. All rights reserved.

  20. International Conference on Bio-Medical Instrumentation and related Engineering and Physical Sciences (BIOMEP 2015)

    Science.gov (United States)

    2015-09-01

    The International Conference on Bio-Medical Instrumentation and related Engineering and Physical Sciences (BIOMEP 2015) took place in the Technological Educational Institute (TEI) of Athens, Greece on June 18-20, 2015 and was organized by the Department of Biomedical Engineering. The scope of the conference was to provide a forum on the latest developments in Biomedical Instrumentation and related principles of Physical and Engineering sciences. Scientists and engineers from academic, industrial and health disciplines were invited to participate in the Conference and to contribute both in the promotion and dissemination of the scientific knowledge.

  1. The modified patient enablement instrument: a Portuguese cross-cultural adaptation, validity and reliability study.

    Science.gov (United States)

    Remelhe, Mafalda; Teixeira, Pedro M; Lopes, Irene; Silva, Luís; Correia de Sousa, Jaime

    2017-01-12

    Enabling patients with asthma to obtain the knowledge, confidence and skills they need in order to assume a major role in the management of their disease is cost effective. It should be an integral part of any plan for long-term control of asthma. The modified Patient Enablement Instrument (mPEI) is an easily administered questionnaire that was adapted in the United Kingdom to measure patient enablement in asthma, but its applicability in Portugal is not known. Validity and reliability of questionnaires should be tested before use in settings different from those of the original version. The purpose of this study was to test the applicability of the mPEI to Portuguese asthma patients after translation and cross-cultural adaptation, and to verify the structural validity, internal consistency and reproducibility of the instrument. The mPEI was translated to Portuguese and back translated to English. Its content validity was assessed by a debriefing interview with 10 asthma patients. The translated instrument was then administered to a random sample of 142 patients with persistent asthma. Structural validity and internal consistency were assessed. For reproducibility analysis, 86 patients completed the instrument again 7 days later. Item-scale correlations and exploratory factor analysis were used to assess structural validity. Cronbach's alpha was used to test internal consistency, and the intra-class correlation coefficient was used for the analysis of reproducibility. All items of the Portuguese version of the mPEI were found to be equivalent to the original English version. There were strong item-scale correlations that confirmed construct validity, with a one component structure and good internal consistency (Cronbach's alpha >0.8) as well as high test-retest reliability (ICC=0.85). The mPEI showed sound psychometric properties for the evaluation of enablement in patients with asthma making it a reliable instrument for use in research and clinical practice in

  2. Lessons Learned from GOSAT; Instrument Design, Calibration, Operation, Data Processing, and International Collaboration

    Science.gov (United States)

    Kuze, A.; Suto, H.; Shiomi, K.; Nakajima, M.

    2012-12-01

    we target sun glint (specular reflection) points, where the surface reflectance is not uniform or randomly distributed. Over the desert area, where surface reflectance is high and dust layers extend to high altitude, we have to use lower gain to avoid saturation and multiple scattering is complicated. For both ocean high albedo targets, validation data of XCO2 and XCH4 are limited. Validation by airplane become accurate but extrapolation is needed above flight attitude. Comparison of surface pressure between retrieved data and a priori model forecast fields is useful. For such kind of consistency, measurement must be very linear within wide dynamic range. After launch, we are re-evaluating the linearity of the detector, analog circuit and AD converters using a lab-model on the ground. Since launch, we have received feedback about the radiance spectra data from many data users of diverse institutes. We have gathered many calibration and validation data from international collaboration. We have modified the Level 1 algorithm and instrument calibrations several times. We are currently measuring the grid point of the Earth's surface, but the sampling for source and sink retrieval has not been optimized yet. We will present how we have solved problems, which portions of the instrument design we should modify, and items that we have not understood well yet.

  3. [Validity of an instrument for assessing food consumption, food habits and cooking skills in 8-11 years old students].

    Science.gov (United States)

    Lera, Lydia; Fretes, Gabriela; González, Carmen Gloria; Salinas, Judith; Vio del Rio, Fernando

    2015-05-01

    An instrument to measure food knowledge, food consumption, cooking skills, food habits and food expenses at school is necessary to assess changes in food practices. To validate an instrument to measure changes in food knowledge, food consumption, cooking skills, food habits and food expenses in Chilean school children 8 - 11 years from third to fifth grade. A validation of a questionnaire with 42 questions was conducted in two stages: the first to assess temporal stability, concordance and internal consistency in 45 children. The second one to apply the survey, modified with the results of the first stage, in 90 children assessing internal consistency. The first survey with 42 questions showed a reasonable temporal stability, concordance and internal consistency for cooking skills, habits and food expenditure at school. Internal consistency was good for food consumption, but not so good for food knowledge. In the final validation with 90 children, there was good consistency for food consumption but bad for food knowledge. Besides, children with cooking skills ate more healthy food and those who expended more money at school, consumed less healthy food. Food knowledge questions were eliminated from the instrument, which was elaborated with 28 questions about food consumption, cooking skills, food habits and food expenses at school. This instrument is useful to assess changes in food and nutrition education interventions in 8 -11 years children, in particular to measure cooking skills and food expenses at school. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  4. Consistent adoption of the International System of Units (SI) in nuclear science and technology

    Energy Technology Data Exchange (ETDEWEB)

    Klumpar, J; Kovar, Z [Ceskoslovenska Akademie Ved, Prague. Laborator Radiologicke Dozimetrie; Sacha, J [Slovenska Akademia Vied, Bratislava (Czechoslovakia). Fyzikalny Ustav

    1975-11-01

    The principles are stressed behind a consistent introduction of the International System of Units (SI) in Czechoslovakia complying with the latest edition of the Czechoslovak Standard CSN 01 1300 on the prescribed system of national and international units. The use of special and auxiliary units in nuclear physics and technology is discussed, particular attention being devoted to the units of activity and to the time units applied in radiology. Conversion graph and tables are annexed.

  5. Assessment report on NRP sub-theme 'International instruments for climate change policy'

    International Nuclear Information System (INIS)

    Bruggink, J.J.C.; Van Beek, P.; Folmer, H.; Zhang, Z.X.; Blok, K.; Phylipsen, D.; Worrell, E.; Gupta, J.; Junne, G.; Van der Wurff, R.

    1995-01-01

    The projects implemented in the Dutch National Research Programme on Global Air Pollution and Climate Change are organised in several themes and sub-themes. Within the theme on Sustainable Solutions five projects are grouped under the heading International Instruments for Climate Change Policy. These five projects deal primarily with issues concerning the position of developing countries in the debate on limiting global CO2-emissions. They cover a broad spectrum of topics: international negotiation strategies, tropical deforestation, industrial energy conservation, national energy scenarios, emission guidelines. This contribution presents an overview of the objectives, methodologies and results of the projects and includes a critical evaluation of the potential relevance of the work for policy makers. 1 tab., 36 refs

  6. Factorial validity and internal consistency of the motivational climate in physical education scale.

    Science.gov (United States)

    Soini, Markus; Liukkonen, Jarmo; Watt, Anthony; Yli-Piipari, Sami; Jaakkola, Timo

    2014-01-01

    The aim of the study was to examine the construct validity and internal consistency of the Motivational Climate in Physical Education Scale (MCPES). A key element of the development process of the scale was establishing a theoretical framework that integrated the dimensions of task- and ego involving climates in conjunction with autonomy, and social relatedness supporting climates. These constructs were adopted from the self-determination and achievement goal theories. A sample of Finnish Grade 9 students, comprising 2,594 girls and 1,803 boys, completed the 18-item MCPES during one physical education class. The results of the study demonstrated that participants had highest mean in task-involving climate and the lowest in autonomy climate and ego-involving climate. Additionally, autonomy, social relatedness, and task- involving climates were significantly and strongly correlated with each other, whereas the ego- involving climate had low or negligible correlations with the other climate dimensions.The construct validity of the MCPES was analyzed using confirmatory factor analysis. The statistical fit of the four-factor model consisting of motivational climate factors supporting perceived autonomy, social relatedness, task-involvement, and ego-involvement was satisfactory. The results of the reliability analysis showed acceptable internal consistencies for all four dimensions. The Motivational Climate in Physical Education Scale can be considered as psychometrically valid tool to measure motivational climate in Finnish Grade 9 students. Key PointsThis study developed Motivational Climate in School Physical Education Scale (MCPES). During the development process of the scale, the theoretical framework using dimensions of task- and ego involving as well as autonomy, and social relatedness supporting climates was constructed. These constructs were adopted from the self-determination and achievement goal theories.The statistical fit of the four-factor model of the

  7. WOrk-Related Questionnaire for UPper extremity disorders (WORQ-UP): Factor Analysis and Internal Consistency.

    Science.gov (United States)

    Aerts, Bas R; Kuijer, P Paul; Beumer, Annechien; Eygendaal, Denise; Frings-Dresen, Monique H

    2018-04-17

    To test a 17-item questionnaire, the WOrk-Related Questionnaire for UPper extremity disorders (WORQ-UP), for dimensionality of the items (factor analysis) and internal consistency. Cross-sectional study. Outpatient clinic. A consecutive sample of patients (N=150) consisting of all new referral patients (either from a general physician or other hospital) who visited the orthopedic outpatient clinic because of an upper extremity musculoskeletal disorder. Not applicable. Number and dimensionality of the factors in the WORQ-UP. Four factors with eigenvalues (EVs) >1.0 were found. The factors were named exertion, dexterity, tools & equipment, and mobility. The EVs of the factors were, respectively, 5.78, 2.38, 1.81, and 1.24. The factors together explained 65.9% of the variance. The Cronbach alpha values for these factors were, respectively, .88, .74, .87, and .66. The 17 items of the WORQ-UP resemble 4 factors-exertion, dexterity, tools & equipment, and mobility-with a good internal consistency. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  8. Internal Consistency and Concurrent Validity of the Questionnaire for Limitations and Restrictions Assessment in Children with ADHD

    Directory of Open Access Journals (Sweden)

    Luisa Matilde Salamanca-Duque

    2014-09-01

    Full Text Available Introduction: ADHD is one of the most common diagnoses in child psychiatry, its early diagnosis is of great importance for intervention at family, school and social environment. Based on the International Classification of Functioning, Disability and Health (ICF, a questionnaire was designed to assess activity limitations and participation restrictions in children with ADHD. The questionnaire was called “CLARP-ADHD Parent and Teacher Version”. Objective: To determine the degree of internal consistency of the CLARP-ADHD questionnaire, and its concurrent validity with the “Strengths and Difficulties Questionnaire SDQ parent and teacher version”. Material and Methods: A sample of 203 children aged 6 to 12 with ADHD, currently attending school in five Colombian cities. The questionnaires were applied to parents and teachers. The internal consistency analysis was performed through Cronbach coefficient and concurrent validity using the Spearman correlation coefficient utilizing multiple and unique predictors through multiple linear regression as well as simple regression models. Results: A high internal consistency was found for global questionnaires for each of its domains. The CLARP-ADHD for parents gave as result an internal consistency of 0.83, and the CLARP-ADHD for teachers one of 0.93. Concurrent validity was found between the CLARP-ADHD and the SDQ Parent and Teacher version; also, concurrence between the CLARPADHD for Teachers and the SDQ Teachers was found, as well as between CLARP ADHD for Parents and CLARP ADHD Teachers, given by p values of p < 0.001.

  9. WHO FCTC as a Pioneering and Learning Instrument Comment on "The Legal Strength of International Health Instruments - What It Brings to Global Health Governance?"

    Science.gov (United States)

    Puska, Pekka

    2017-05-23

    The World Health Organization (WHO) Framework Convention on Tobacco Control (FCTC) is a unique global health instrument, since it is in the health field the only instrument that is international law. After the 10 years of its existence an Independent Expert Group assessed the impact of the FCTC using all available data and visiting a number of countries interviewing different stakeholders. It is quite clear that the Treaty has acted as a strong catalyst and framework for national actions and that remarkable progress in global tobacco control can be seen. At the same time FCTC has moved tobacco control in countries from a pure health issue to a legal responsibility of the whole government, and on the international level created stronger interagency collaboration. The assessment also showed the many challenges. The spread of tobacco use, as well as of other risk lifestyles, is related to globalization. FCTC is a pioneering example of global action to counteract the negative social consequences of globalization. A convention is not an easy instrument, but the FCTC has undoubtedly sparked thinking and development of other stronger public health instruments and of needed governance structures. © 2018 The Author(s); Published by Kerman University of Medical Sciences. This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  10. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  11. The Student Actions Coding Sheet (SACS): An instrument for illuminating the shifts toward student-centered science classrooms

    Science.gov (United States)

    Erdogan, Ibrahim; Campbell, Todd; Hashidah Abd-Hamid, Nor

    2011-07-01

    This study describes the development of an instrument to investigate the extent to which student-centered actions are occurring in science classrooms. The instrument was developed through the following five stages: (1) student action identification, (2) use of both national and international content experts to establish content validity, (3) refinement of the item pool based on reviewer comments, (4) pilot testing of the instrument, and (5) statistical reliability and item analysis leading to additional refinement and finalization of the instrument. In the field test, the instrument consisted of 26 items separated into four categories originally derived from student-centered instruction literature and used by the authors to sort student actions in previous research. The SACS was administered across 22 Grade 6-8 classrooms by 22 groups of observers, with a total of 67 SACS ratings completed. The finalized instrument was found to be internally consistent, with acceptable estimates from inter-rater intraclass correlation reliability coefficients at the p Observation Protocol. Based on the analyses completed, the SACS appears to be a useful instrument for inclusion in comprehensive assessment packages for illuminating the extent to which student-centered actions are occurring in science classrooms.

  12. The Internal Consistency and Validity of the Vaccination Attitudes Examination Scale: A Replication Study.

    Science.gov (United States)

    Wood, Louise; Smith, Michael; Miller, Christopher B; O'Carroll, Ronan E

    2018-06-19

    Vaccinations are important preventative health behaviors. The recently developed Vaccination Attitudes Examination (VAX) Scale aims to measure the reasons behind refusal/hesitancy regarding vaccinations. The aim of this replication study is to conduct an independent test of the newly developed VAX Scale in the UK. We tested (a) internal consistency (Cronbach's α); (b) convergent validity by assessing its relationships with beliefs about medication, medical mistrust, and perceived sensitivity to medicines; and (c) construct validity by testing how well the VAX Scale discriminated between vaccinators and nonvaccinators. A sample of 243 UK adults completed the VAX Scale, the Beliefs About Medicines Questionnaire, the Perceived Sensitivity to Medicines Scale, and the Medical Mistrust Index, in addition to demographics of age, gender, education levels, and social deprivation. Participants were asked (a) whether they received an influenza vaccination in the past year and (b) if they had a young child, whether they had vaccinated the young child against influenza in the past year. The VAX (a) demonstrated high internal consistency (α = .92); (b) was positively correlated with medical mistrust and beliefs about medicines, and less strongly correlated with perceived sensitivity to medicines; and (c) successfully differentiated parental influenza vaccinators from nonvaccinators. The VAX demonstrated good internal consistency, convergent validity, and construct validity in an independent UK sample. It appears to be a useful measure to help us understand the health beliefs that promote or deter vaccination behavior.

  13. Instrumental interaction

    OpenAIRE

    Luciani , Annie

    2007-01-01

    International audience; The expression instrumental interaction as been introduced by Claude Cadoz to identify a human-object interaction during which a human manipulates a physical object - an instrument - in order to perform a manual task. Classical examples of instrumental interaction are all the professional manual tasks: playing violin, cutting fabrics by hand, moulding a paste, etc.... Instrumental interaction differs from other types of interaction (called symbolic or iconic interactio...

  14. Proceedings of the 38th international instrumentation symposium

    International Nuclear Information System (INIS)

    Richter, S.H.; Smith, E.A.

    1991-01-01

    This volume covers the proceedings of a symposium on instrumentation within the Aerospace and Test Measurement Divisions of the Instrument Society of America. Topics covered included: PC control in turbine engine testing, energy measurement of high proton beams, instrumentation for sampling related to the US clean Air Act, and instrumentation for monitoring in-reactor severe fuel damage tests

  15. Validity and reliability of the Mastication Observation and Evaluation (MOE) instrument.

    Science.gov (United States)

    Remijn, Lianne; Speyer, Renée; Groen, Brenda E; van Limbeek, Jacques; Nijhuis-van der Sanden, Maria W G

    2014-07-01

    The Mastication Observation and Evaluation (MOE) instrument was developed to allow objective assessment of a child's mastication process. It contains 14 items and was developed over three Delphi rounds. The present study concerns the further development of the MOE using the COSMIN (Consensus based Standard for the Selection of Measurement Instruments) and investigated the instrument's internal consistency, inter-observer reliability, construct validity and floor and ceiling effects. Consumption of three bites of bread and biscuit was evaluated using the MOE. Data of 59 healthy children (6-48 mths) and 38 children (bread) and 37 children (biscuit) with cerebral palsy (24-72 mths) were used. Four items were excluded before analysis due to zero variance. Principal Components Analysis showed one factor with 8 items. Internal consistency was >0.70 (Chronbach's alpha) for both food consistencies and for both groups of children. Inter-observer reliability varied from 0.51 to 0.98 (weighted Gwet's agreement coefficient). The total MOE scores for both groups showed normal distribution for the population. There were no floor or ceiling effects. The revised MOE now contains 8 items that (a) have a consistent concept for mastication and can be scored on a 4-point scale with sufficient reliability and (b) are sensitive to stages of chewing development in young children. The removed items are retained as part of a criterion referenced list within the MOE. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Factorial Validity and Internal Consistency of the Motivational Climate in Physical Education Scale

    Directory of Open Access Journals (Sweden)

    Markus Soini

    2014-03-01

    Full Text Available The aim of the study was to examine the construct validity and internal consistency of the Motivational Climate in Physical Education Scale (MCPES. A key element of the development process of the scale was establishing a theoretical framework that integrated the dimensions of task- and ego involving climates in conjunction with autonomy, and social relatedness supporting climates. These constructs were adopted from the self-determination and achievement goal theories. A sample of Finnish Grade 9 students, comprising 2,594 girls and 1,803 boys, completed the 18-item MCPES during one physical education class. The results of the study demonstrated that participants had highest mean in task-involving climate and the lowest in autonomy climate and ego-involving climate. Additionally, autonomy, social relatedness, and task- involving climates were significantly and strongly correlated with each other, whereas the ego- involving climate had low or negligible correlations with the other climate dimensions.The construct validity of the MCPES was analyzed using confirmatory factor analysis. The statistical fit of the four-factor model consisting of motivational climate factors supporting perceived autonomy, social relatedness, task-involvement, and ego-involvement was satisfactory. The results of the reliability analysis showed acceptable internal consistencies for all four dimensions. The Motivational Climate in Physical Education Scale can be considered as psychometrically valid tool to measure motivational climate in Finnish Grade 9 students.

  17. Internal consistency of a five-item form of the Francis Scale of Attitude Toward Christianity among adolescent students.

    Science.gov (United States)

    Campo-Arias, Adalberto; Oviedo, Heidi Celina; Cogollo, Zuleima

    2009-04-01

    The short form of the Francis Scale of Attitude Toward Christianity (L. J. Francis, 1992) is a 7-item Likert-type scale that shows high homogeneity among adolescents. The psychometric performance of a shorter version of this scale has not been explored. The authors aimed to determine the internal consistency of a 5-item form of the Francis Scale of Attitude Toward Christianity among 405 students from a school in Cartagena, Colombia. The authors computed the Cronbach's alpha coefficient for the 5 items with a greater corrected item-total punctuation correlation. The version without Items 2 and 7 showed internal consistency of .87. The 5-item version of the Francis Scale of Attitude Toward Christianity exhibited higher internal consistency than did the 7-item version. Future researchers should corroborate this finding.

  18. [Instruments for evaluating oral health knowledge, attitudes and practice for parents /caregivers of small children].

    Science.gov (United States)

    Martignon, Stefania; Bautista-Mendoza, Gloria; González-Carrera, María; Lafaurie-Villamil, Gloria; Morales, Veicy; Santamaría, Ruth

    2008-01-01

    Designing three instruments for evaluating oral health knowledge, attitudes and practice in parents/caregivers of low social-economic status 0-5 year-olds. Evaluating the instruments' reliability in terms of internal consistency and analysing items. Three instruments were constructed for evaluating low social-economic status 0-5 year-olds' parents/caregivers' oral health knowledge, attitudes and practice in the municipality of Usaquén , Bogotá , Colombia . 47 parents/caregivers were given a test establishing the instrument's reliability in terms of internal consistency and the adults' level of knowledge, attitudes and practice. A sub-sample was qualitatively analysed (content verification and understanding). Reliability was evaluated using Cronbach's alpha coefficient. Items were analysed for improving constructing and understanding the questions, taking four criteria into account: corrected homogeneity index (CHI), response trend, correlation between items and qualitative analysis. Cronbach's alpha coefficient for knowledge, attitudes and practice was 0,82, 0,80 and 0,62, respectively. Participants' level of knowledge, attitudes and practice was acceptable (60 %, 55 % and 91 %, respectively). This study found two out of the three evaluated instruments to be reliable (knowledge and attitudes); all three of them were then redesigned. The resulting instruments represent a valuable tool which can be used in future studies for describing and evaluating preventative programmes.

  19. Quality appraisal of generic self-reported instruments measuring health-related productivity changes: a systematic review

    Science.gov (United States)

    2014-01-01

    Background Health impairments can result in disability and changed work productivity imposing considerable costs for the employee, employer and society as a whole. A large number of instruments exist to measure health-related productivity changes; however their methodological quality remains unclear. This systematic review critically appraised the measurement properties in generic self-reported instruments that measure health-related productivity changes to recommend appropriate instruments for use in occupational and economic health practice. Methods PubMed, PsycINFO, Econlit and Embase were systematically searched for studies whereof: (i) instruments measured health-related productivity changes; (ii) the aim was to evaluate instrument measurement properties; (iii) instruments were generic; (iv) ratings were self-reported; (v) full-texts were available. Next, methodological quality appraisal was based on COSMIN elements: (i) internal consistency; (ii) reliability; (iii) measurement error; (iv) content validity; (v) structural validity; (vi) hypotheses testing; (vii) cross-cultural validity; (viii) criterion validity; and (ix) responsiveness. Recommendations are based on evidence syntheses. Results This review included 25 articles assessing the reliability, validity and responsiveness of 15 different generic self-reported instruments measuring health-related productivity changes. Most studies evaluated criterion validity, none evaluated cross-cultural validity and information on measurement error is lacking. The Work Limitation Questionnaire (WLQ) was most frequently evaluated with moderate respectively strong positive evidence for content and structural validity and negative evidence for reliability, hypothesis testing and responsiveness. Less frequently evaluated, the Stanford Presenteeism Scale (SPS) showed strong positive evidence for internal consistency and structural validity, and moderate positive evidence for hypotheses testing and criterion validity. The

  20. Assessment of disabilities in stroke patients with apraxia : Internal consistency and inter-observer reliability

    NARCIS (Netherlands)

    van Heugten, CM; Dekker, J; Deelman, BG; Stehmann-Saris, JC; Kinebanian, A

    1999-01-01

    In this paper the internal consistency and inter-observer reliability of the assessment of disabilities in stroke patients with apraxia is presented. Disabilities were assessed by means of observation of activities of daily living (ADL). The study was conducted at occupational therapy departments in

  1. Assessment of disabilities in stroke patients with apraxia: internal consistency and inter-observer reliability.

    NARCIS (Netherlands)

    Heugten, C.M. van; Dekker, J.; Deelman, B.G.; Stehmann-Saris, J.C.; Kinebanian, A.

    1999-01-01

    In this paper the internal consistency and inter-observer reliability of the assessment of disabilities in stroke patients with apraxia is presented. Disabilities were assessed by means of observation of activities of daily living (ADL). The study was conducted at occupational therapy departments in

  2. Internal consistency and factor structure of the Portuguese version of the Liebowitz Social Anxiety Scale among alcoholic patients Consistência interna e estrutura fatorial da versão em português da Escala de Ansiedade Social de Liebowitz entre pacientes alcoolistas

    Directory of Open Access Journals (Sweden)

    Mauro B Terra

    2006-12-01

    Full Text Available OBJECTIVE: Liebowitz Social Anxiety Scale is an instrument used to evaluate the severity of social phobia. It has been widely used in different contexts and cultures, presenting variable psychometric properties. The objective of this article is to investigate the internal consistency and the factor structure of this scale. METHOD: In a sample of 300 alcoholic patients hospitalized in 3 mental clinics in Southern Brazil, 74 of them were social phobics (24.6%. The Structured Clinical Interview for DSM-IV-Axis I Disorders - Patient Edition, a semi-structured clinical interview based on DSM-IV, was used to check for the diagnosis of social phobia. The internal consistency was measured by Cronbach's alpha. Data were subjected to a factor analysis with the principal component method of parameter estimation. Questionnaire items loading at 0.35 or above were considered in the final factor solution. RESULTS: The coefficient of internal consistency was 0.95. All items showed corrected item-total correlation coefficient above 0.15, considered the minimum requested index. The factor analysis resulted in 5 dimensions which corresponded to 52.9% of the total variance. The five factors extracted were: factor I - speaking in a group, factor II - activity in public, factor III - social interaction with unknown person, factor IV - attitude of disagreement or disapproval and factor V - social interaction in leisure activity. CONCLUSIONS: The scale proved to be reliable and structurally valid instrument for use in a population of alcoholic patients. The possibility of screening for social phobia through the use of the instrument may be helpful in identifying probable cases of the disorder among alcoholics.OBJETIVO: A Escala de Ansiedade Social de Liebowitz é um instrumento utilizado na avaliação da gravidade da fobia social. Tem sido amplamente usada em diferentes contextos e culturas, apresentando propriedades psicométricas variadas. O objetivo do artigo

  3. International cooperation for the development of consistent and stable transportation regulations to promote and enhance safety and security

    International Nuclear Information System (INIS)

    Strosnider, J.

    2004-01-01

    International commerce of radioactive materials crosses national boundaries, linking separate regulatory institutions with a common purpose and making it necessary for these institutions to work together in order to achieve common safety goals in a manner that does not place an undue burden on industry and commerce. Widespread and increasing use of radioactive materials across the world has led to increases in the transport of radioactive materials. The demand for consistency in the oversight of international transport has also increased to prevent unnecessary delays and costs associated with incongruent or redundant regulatory requirements by the various countries through which radioactive material is transported. The International Atomic Energy Agency (IAEA) is the authority for international regulation of transportation of radioactive materials responsible for promulgation of regulations and guidance for the establishment of acceptable methods of transportation for the international community. As such, the IAEA is seen as the focal point for consensus building between its Member States to develop consistency in transportation regulations and reviews and to ensure the safe and secure transport of radioactive material. International cooperation is also needed to ensure stability in our regulatory processes. Changes to transportation regulations should be based on an anticipated safety benefit supported by risk information and insights gained from continuing experience, evaluation, and research studies. If we keep safety as the principle basis for regulatory changes, regulatory stability will be enhanced. Finally, as we endeavour to maintain consistency and stability in our international regulations, we must be mindful of the new security challenges that lay before the international community as a result of a changing terrorist environment. Terrorism is a problem of global concern that also requires international cooperation and support, as we look for ways to

  4. The Brazilian version of the Constant-Murley Score (CMS-BR): convergent and construct validity, internal consistency, and unidimensionality.

    Science.gov (United States)

    Barreto, Rodrigo Py Gonçalves; Barbosa, Marcus Levi Lopes; Balbinotti, Marcos Alencar Abaide; Mothes, Fernando Carlos; da Rosa, Luís Henrique Telles; Silva, Marcelo Faria

    2016-01-01

    To translate and culturally adapt the CMS and assess the validity of the Brazilian version (CMS-BR). The translation was carried out according to the back-translation method by four independent translators. The produced versions were synthesized through extensive analysis and by consensus of an expert committee, reaching a final version used for the cultural adaptation. A field test was conducted with 30 subjects in order to obtain semantic considerations. For the psychometric analyzes, the sample was increased to 110 participants who answered two instruments: CMS-BR and the Disabilities of the Arm, shoulder and Hand (DASH). The CMS-BR and DASH score range from 0 to 100 points. For the first, higher points reflect better function and for the latter, the inverse is true. The validity was verified by Pearson's correlation test, the unidimensionality by factorial analysis, and the internal consistency by Cronbach's alpha. The explained variance was 60.28% with factor loadings ranging from 0.60 to 0.91. The CMS-BR exhibited strong negative correlation with the DASH score (-0.82, p  CMS was satisfactorily adapted for Brazilian Portuguese and demonstrated evidence of validity that allows its use in this population.

  5. Confirmatory factor analysis of teaching and learning guiding principles instrument among teacher educators in higher education institutions

    Science.gov (United States)

    Masuwai, Azwani; Tajudin, Nor'ain Mohd; Saad, Noor Shah

    2017-05-01

    The purpose of this study is to develop and establish the validity and reliability of an instrument to generate teaching and learning guiding principles using Teaching and Learning Guiding Principles Instrument (TLGPI). Participants consisted of 171 Malaysian teacher educators. It is an essential instrument to reflect in generating the teaching and learning guiding principles in higher education level in Malaysia. Confirmatory Factor Analysis has validated all 19 items of TLGPI whereby all items indicated high reliability and internal consistency. A Confirmatory Factor Analysis also confirmed that a single factor model was used to generate teaching and learning guiding principles.

  6. Instrument evaluation no. 33. Automess Szintomat 6134 radiation survey meter

    International Nuclear Information System (INIS)

    McClure, D.R.

    1986-04-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This instrument evaluation report deals with the Automess Szintomat 6134 Radiation Survey Meter

  7. Internal Consistency of Performance Evaluations as a Function of Music Expertise and Excerpt Familiarity

    Science.gov (United States)

    Kinney, Daryl W.

    2009-01-01

    The purpose of this study was to examine the effects of music experience and excerpt familiarity on the internal consistency of performance evaluations. Participants included nonmusic majors who had not participated in high school music ensembles, nonmusic majors who had participated in high school music ensembles, music majors, and experts…

  8. Internal consistency & validity of Indian Disability Evaluation and Assessment Scale (IDEAS in patients with schizophrenia

    Directory of Open Access Journals (Sweden)

    Sandeep Grover

    2014-01-01

    Full Text Available Background & objectives: The Indian Disability Evaluation and Assessment Scale (IDEAS has been recommended for assessment and certification of disability by the Government of India (GOI. However, the psychometric properties of IDEAS as adopted by GOI remain understudied. Our aim, thus, was to study the internal consistency and validity of IDEAS in patients with schizophrenia. Methods: A total of 103 consenting patients with residual schizophrenia were assessed for disability, quality of life (QOL and psychopathology using the IDEAS, WHO QOL-100 and Positive and Negative symptom scale (PANSS respectively. Internal consistency was calculated using Cronbach′s alpha. For construct validity, relations between IDEAS, and psychopathology and QOL were studied. Results: The inter-item correlations for IDEAS were significant with a Cronbach′s alpha of 0.721. All item scores other than score on communication and understanding; total and global IDEAS scores correlated significantly with the positive, negative and general sub-scales, and total PANSS scores. Communication and understanding was significantly related to negative sub-scale score only. Total and global disability scores correlated negatively with all the domains of WHOQOL-100 (ρ<0.01. The individual IDEAS item scores correlated negatively with various WHOQOL-100 domains (ρ0< 0.01. Interpretation & conclusions: This study findings showed that the GOI-modified IDEAS had good internal consistency and construct validity as tested in patients with residual schizophrenia. Similar studies need to be done with other groups of patients.

  9. A summary of the performance of exposure rate and dose rate instruments contained in instrument evaluation reports NRPB-IE1 to NRPB-IE13

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1979-06-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This report provides a concise summary of measurements of the more important performance characteristics of radiation protection dose rate or exposure rate survey instruments which have been assessed by NRPB as part

  10. Instrument evaluation no. 13. Nuclear enterprises portable meter type PDR

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-06-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This report deals with the evaluation of Nuclear Enterprises Portable Dose Rate Meter Type PDR 2

  11. Instrument Psychometrics: Parental Satisfaction and Quality Indicators of Perinatal Palliative Care.

    Science.gov (United States)

    Wool, Charlotte

    2015-10-01

    Despite a life-limiting fetal diagnosis, prenatal attachment often occurs in varying degrees resulting in role identification by an individual as a parent. Parents recognize quality care and report their satisfaction when interfacing with health care providers. The aim was to test an instrument measuring parental satisfaction and quality indicators with parents electing to continue a pregnancy after learning of a life-limiting fetal diagnosis. A cross sectional survey design gathered data using a computer-mediated platform. Subjects were parents (n=405) who opted to continue a pregnancy affected by a life-limiting diagnosis. Factor analysis using principal component analysis with Varimax rotation was used to validate the instrument, evaluate components, and summarize the explained variance achieved among quality indicator items. The Prenatal Scale was reduced to 37 items with a three-component solution explaining 66.19% of the variance and internal consistency reliability of 0.98. The Intrapartum Scale included 37 items with a four-component solution explaining 66.93% of the variance and a Cronbach α of 0.977. The Postnatal Scale was reduced to 44 items with a six-component solution explaining 67.48% of the variance. Internal consistency reliability was 0.975. The Parental Satisfaction and Quality Indicators of Perinatal Palliative Care Instrument is a valid and reliable measure for parent-reported quality care and satisfaction. Use of this instrument will enable clinicians and researchers to measure quality indicators and parental satisfaction. The instrument is useful for assessing, analyzing, and reporting data on quality for care delivered during the prenatal, intrapartum, and postnatal periods.

  12. [Psychometric properties of an instrument for assessing cyber-sex addiction].

    Science.gov (United States)

    Ballester Arnal, Rafael; Gil Llario, Ma Dolores; Gómez Martínez, Sandra; Gil Juliá, Beatriz

    2010-11-01

    Psychometric properties of an instrument for assessing cyber-sex addiction. Cyber-sex addiction is a «new pathology» whose prevalence has grown rapidly in recent years. Therefore, it is important to have validated assessment instruments. The aim of this study was the adaptation and validation of the Internet Sex Screening Test (ISST) for its use in a Spanish population. The instrument was administered to 1239 Spanish college students. The results yielded five components that account for 47.5% of the variance. Internal consistency was .88 and temporal stability was .84. Moreover, the instrument had adequate convergent and discriminant validity and was related to other behaviors such as the use of pornography, internet addiction, number of hours online and sexual frequency. Therefore, this tool is proposed as an appropriate measure to assess cyber-sex addiction.

  13. Measuring quality in community based housing support - the QPC-H instrument.

    Science.gov (United States)

    Lundqvist, Lars-Olov; Rask, Mikael; Brunt, David; Ivarsson, Ann-Britt; Schröder, Agneta

    2016-04-18

    Purpose - The purpose of this paper is to test the psychometric properties and dimensionality of the instrument Quality in Psychiatric Care-Housing (QPC-H) and briefly describe the residents' perception of quality of housing support. Design/methodology/approach - A sample of 174 residents from 22 housing support services in nine Swedish municipalities participated in the study. Confirmatory factor analysis (CFA) revealed that the QPC-H consisted of six dimensions and had a factor structure largely corresponding to that found among other instruments in the Quality in Psychiatric Care (QPC) family of instruments. Findings - CFA revealed that the QPC-H consisted of six dimensions and had a factor structure largely corresponding to that found among other instruments in the QPC family of instruments. The internal consistency of the factors was acceptable except in the case of secure and secluded environment, probably due to few numbers of items. With this exception, the QPC-H shows adequate psychometric properties. Social implications - The residents' ratings of quality of housing service were generally high; the highest rating was for secluded environment and the lowest for participation. This dimension would thus seem to indicate an important area for improvement. Originality/value - The QPC-H includes important aspects of residents' assessment of quality of housing service and offers a simple and inexpensive way to evaluate housing support services from the residents' perspective.

  14. Instrumentation for Nuclear Applications

    International Nuclear Information System (INIS)

    1998-01-01

    The objective of this project was to develop and coordinate nuclear instrumentation standards with resulting economies for the nuclear and radiation fields. There was particular emphasis on coordination and management of the Nuclear Instrument Module (NIM) System, U.S. activity involving the CAMAC international standard dataway system, the FASTBUS modular high-speed data acquisition and control system and processing and management of national nuclear instrumentation and detector standards, as well as a modest amount of assistance and consultation services to the Pollutant Characterization and Safety Research Division of the Office of Health and Environmental Research. The principal accomplishments were the development and maintenance of the NIM instrumentation system that is the predominant instrumentation system in the nuclear and radiation fields worldwide, the CAMAC digital interface system in coordination with the ESONE Committee of European Laboratories, the FASTBUS high-speed system and numerous national and international nuclear instrumentation standards

  15. Internal consistency, reliability, and temporal stability of the Oxford Happiness Questionnaire short-form: Test-retest data over two weeks

    OpenAIRE

    MCGUCKIN, CONOR

    2006-01-01

    PUBLISHED The Oxford Happiness Questionnaire short-form is a recently developed eight-item measure of happiness. This study evaluated the internal consistency reliability and test-retest reliability of the Oxford Happiness Questionnaire short-form among 55 Northern Irish undergraduate university students who completed the measure on two occasions separated by two weeks. Internal consistency of the measure on both occasions was satisfactory at both Time 1 (alpha = .62) and Time 2 (alpha = ....

  16. Voluntary agreements as instruments for international environmental policy; Frivillege avtaler som internasjonalt miljoepolitisk verkemiddel

    Energy Technology Data Exchange (ETDEWEB)

    Torvanger, Asbjoern

    1997-12-31

    According to this report, voluntary agreements have a potential as instruments for environmental policy. Such agreements can be national or international. Through an international voluntary agreement the authorities in one country may make contracts with factories in another country about emission reductions against some kind of compensation. A supranational organisation of voluntary agreements may ensure equal environmental political conditions for factories in different countries and be a useful means for the regulation of environmental problems of regional or global extent. It is most realistic to establish a supranational system of voluntary agreements in a group of countries that have already institutionalized their relations, such as the European Union. 14 refs., 1 table

  17. Reliability of Instruments Measuring At-Risk and Problem Gambling Among Young Individuals

    DEFF Research Database (Denmark)

    Edgren, Robert; Castrén, Sari; Mäkelä, Marjukka

    2016-01-01

    This review aims to clarify which instruments measuring at-risk and problem gambling (ARPG) among youth are reliable and valid in light of reported estimates of internal consistency, classification accuracy, and psychometric properties. A systematic search was conducted in PubMed, Medline, and Psyc......Info covering the years 2009–2015. In total, 50 original research articles fulfilled the inclusion criteria: target age under 29 years, using an instrument designed for youth, and reporting a reliability estimate. Articles were evaluated with the revised Quality Assessment of Diagnostic Accuracy Studies tool....... Reliability estimates were reported for five ARPG instruments. Most studies (66%) evaluated the South Oaks Gambling Screen Revised for Adolescents. The Gambling Addictive Behavior Scale for Adolescents was the only novel instrument. In general, the evaluation of instrument reliability was superficial. Despite...

  18. Impact of Alzheimer's Disease on Caregiver Questionnaire: internal consistency, convergent validity, and test-retest reliability of a new measure for assessing caregiver burden.

    Science.gov (United States)

    Cole, Jason C; Ito, Diane; Chen, Yaozhu J; Cheng, Rebecca; Bolognese, Jennifer; Li-McLeod, Josephine

    2014-09-04

    There is a lack of validated instruments to measure the level of burden of Alzheimer's disease (AD) on caregivers. The Impact of Alzheimer's Disease on Caregiver Questionnaire (IADCQ) is a 12-item instrument with a seven-day recall period that measures AD caregiver's burden across emotional, physical, social, financial, sleep, and time aspects. Primary objectives of this study were to evaluate psychometric properties of IADCQ administered on the Web and to determine most appropriate scoring algorithm. A national sample of 200 unpaid AD caregivers participated in this study by completing the Web-based version of IADCQ and Short Form-12 Health Survey Version 2 (SF-12v2™). The SF-12v2 was used to measure convergent validity of IADCQ scores and to provide an understanding of the overall health-related quality of life of sampled AD caregivers. The IADCQ survey was also completed four weeks later by a randomly selected subgroup of 50 participants to assess test-retest reliability. Confirmatory factor analysis (CFA) was implemented to test the dimensionality of the IADCQ items. Classical item-level and scale-level psychometric analyses were conducted to estimate psychometric characteristics of the instrument. Test-retest reliability was performed to evaluate the instrument's stability and consistency over time. Virtually none (2%) of the respondents had either floor or ceiling effects, indicating the IADCQ covers an ideal range of burden. A single-factor model obtained appropriate goodness of fit and provided evidence that a simple sum score of the 12 items of IADCQ can be used to measure AD caregiver's burden. Scales-level reliability was supported with a coefficient alpha of 0.93 and an intra-class correlation coefficient (for test-retest reliability) of 0.68 (95% CI: 0.50-0.80). Low-moderate negative correlations were observed between the IADCQ and scales of the SF-12v2. The study findings suggest the IADCQ has appropriate psychometric characteristics as a

  19. Validation of the PHEEM instrument in a Danish hospital setting

    DEFF Research Database (Denmark)

    Aspegren, Knut; Bastholt, Lars; Bested, K.M.

    2007-01-01

    The Postgraduate Hospital Educational Environment Measure (PHEEM) has been translated into Danish and then validated with good internal consistency by 342 Danish junior and senior hospital doctors. Four of the 40 items are culturally dependent in the Danish hospital setting. Factor analysis...... demonstrated that seven items are interconnected. This information can be used to shorten the instrument by perhaps another three items...

  20. Progress in the specification of optical instruments for the measurement of surface form and texture

    Science.gov (United States)

    de Groot, Peter J.

    2014-05-01

    Specifications for confocal microscopes, optical interferometers and other methods of measuring areal surface topography can be confusing and misleading. The emerging ISO 25178 standards, together with the established international vocabulary of metrology, provide a foundation for improved specifications for 3D surface metrology instrumentation. The approach in this paper links instrument specifications to metrological characteristics that can influence a measurement, using consistent definitions of terms, and reference to verification procedures.

  1. Development of quality of life instrument for urban poor in the northeast of Thailand.

    Science.gov (United States)

    Surit, Phrutthinun; Laohasiriwong, Wongsa; Sanchaisuriya, Pattara; Schelp, Frank Perter

    2008-09-01

    Measuring the quality of life is important for evaluation and prediction of life and social care needs. To evaluate Quality of Life (QOL) in an urban poor population in northeast of Thailand, the Urban Poor Quality of Life (UPQOL) instrument was developed To develop an initial instrument to measure urban poor QOL. The development was started with literature review and investigated in urban poor communities. The results were transformed into the items required to build a structured questionnaire. Five hundred twenty three subjects, representatives of urban poor, were selected to test this instrument. Descriptive statistics described feature of items and the samples, exploratory factor analysis conducted the items score, and confirmatory factor analysis conducted the construct validity. The result found that the UPQOL instrument consisted of nine domains (education, income and employment, environment, health, infrastructure, security and safety, shelter and housing, civil society and political, and human rights domains) with egien value rank from 1.5 to 4.2 and 61 items with the factor loading rank from 0.41 to 0.82. The internal consistency was 0.92. The correlation between items to domain ranged from 0.30 to 0.72 and domains to overall QOL ranged from 0.27 to 0.84. Confirmatory factor analysis showed that the structure fit all domains well. Domains and overall structure were good with CFI (> 0.95). The internal consistency value ranged from 0.73-0.93. UPQOL scores were able to discriminate groups of subjects with differences levels of QOL. The UPQOL instrument is conceptually valid. The results support good validity and reliability. It forms the basis for future testing and application in other settings.

  2. A Unidimensional Instrument for Measuring Internal Marketing Concept in the Higher Education Sector: IM-11 Scale

    Science.gov (United States)

    Yildiz, Suleyman Murat; Kara, Ali

    2017-01-01

    Purpose: Although the existing internal marketing (IM) scales include various scale items to measure employee motivation, they fall short of incorporating the needs and expectations of service sector employees. Hence, the purpose of this study is to present a practical instrument designed to measure the IM construct in the higher education sector.…

  3. Psychometric properties of assessment instruments for autism spectrum disorder: a systematic review of Brazilian studies

    Directory of Open Access Journals (Sweden)

    Bárbara Backes

    2014-07-01

    Full Text Available Objective To systematically review the scientific literature on the psychometric properties of international instruments for the assessment of autism spectrum disorder (ASD in the Brazilian population. Methods A search of bibliographic references was conducted in six electronic databases: PsycINFO, PubMed, IndexPsi, Lilacs, Capes (theses and dissertations and SciELO. The studies were selected by two independent researchers. Results The procedure identified 11 studies of the Brazilian population that encompassed six ASD assessment tools. Given the information provided, the adaptation of the M-CHAT, a screening instrument, was the best conducted. All steps of the adaptation process were described and the changes made to the final version of the instrument were presented, which was not addressed in other studies. In terms of reliability, all of the instruments that assessed internal consistency showed adequate values. In addition, the ADI-R and the CARS adaptations also satisfactorily contemplated inter-rater reliability and test-retest indices, respectively. Finally, all studies aiming to validate instruments showed evidence of validity and sensitivity, and specificity values above 0.90 were observed in the ASQ, ADI-R and ABC. Conclusion Considering both the psychometric aspects and the copyright information, the screening instrument that currently appears to be best indicated for clinical and research use is the M-CHAT. It was also noticed that there are still no specific ASD diagnostic tools available for use in Brazil. This lack of diagnostic instruments consists in a critical situation for the improvement of clinical practice and the development of research in this area.

  4. Item-level psychometrics of the ADL instrument of the Korean National Survey on persons with physical disabilities.

    Science.gov (United States)

    Hong, Ickpyo; Lee, Mi Jung; Kim, Moon Young; Park, Hae Yean

    2017-10-01

    The aim of this study is to investigate the psychometrics of the 12 items of an instrument assessing activities of daily living (ADL) using an item response theory model. A total of 648 adults with physical disabilities and having difficulties in ADLs were retrieved from the 2014 Korean National Survey on People with Disabilities. The psychometric testing included factor analysis, internal consistency, precision, and differential item functioning (DIF) across categories including sex, older age, marital status, and physical impairment area. The sample had a mean age of 69.7 years old (SD = 13.7). The majority of the sample had lower extremity impairments (62.0%) and had at least 2.1 chronic conditions. The instrument demonstrated unidimensional construct and good internal consistency (Cronbach's alpha = 0.95). The instrument precisely estimated person measures within a wide range of theta values (-2.22 logits  5.0%). Our findings indicate that the dressing item would need to be modified to improve its psychometrics. Overall, the ADL instrument demonstrates good psychometrics, and thus, it may be used as a standardized instrument for measuring disability in rehabilitation contexts. However, the findings are limited to adults with physical disabilities. Future studies should replicate psychometric testing for survey respondents with other disorders and for children.

  5. Instrumentation, computer software and experimental techniques used in low-frequency internal friction studies at WNRE

    International Nuclear Information System (INIS)

    Sprugmann, K.W.; Ritchie, I.G.

    1980-04-01

    A detailed and comprehensive account of the equipment, computer programs and experimental methods developed at the Whiteshell Nuclear Research Estalbishment for the study of low-frequency internal friction is presented. Part 1 describes the mechanical apparatus, electronic instrumentation and computer software, while Part II describes in detail the laboratory techniques and various types of experiments performed together with data reduction and analysis. Experimental procedures for the study of internal friction as a function of temperature, strain amplitude or time are described. Computer control of these experiments using the free-decay technique is outlined. In addition, a pendulum constant-amplitude drive system is described. (auth)

  6. Measuring pediatric hematology-oncology fellows' skills in humanism and professionalism: A novel assessment instrument.

    Science.gov (United States)

    Kesselheim, Jennifer C; Agrawal, Anurag K; Bhatia, Nita; Cronin, Angel; Jubran, Rima; Kent, Paul; Kersun, Leslie; Rao, Amulya Nageswara; Rose, Melissa; Savelli, Stephanie; Sharma, Mukta; Shereck, Evan; Twist, Clare J; Wang, Michael

    2017-05-01

    Educators in pediatric hematology-oncology lack rigorously developed instruments to assess fellows' skills in humanism and professionalism. We developed a novel 15-item self-assessment instrument to address this gap in fellowship training. Fellows (N = 122) were asked to assess their skills in five domains: balancing competing demands of fellowship, caring for the dying patient, confronting depression and burnout, responding to challenging relationships with patients, and practicing humanistic medicine. An expert focus group predefined threshold scores on the instrument that could be used as a cutoff to identify fellows who need support. Reliability and feasibility were assessed and concurrent validity was measured using three established instruments: Maslach Burnout Inventory (MBI), Flourishing Scale (FS), and Jefferson Scale of Physician Empathy (JSPE). For 90 participating fellows (74%), the self-assessment proved feasible to administer and had high internal consistency reliability (Cronbach's α = 0.81). It was moderately correlated with the FS and MBI (Pearson's r = 0.41 and 0.4, respectively) and weakly correlated with the JSPE (Pearson's r = 0.15). Twenty-eight fellows (31%) were identified as needing support. The self-assessment had a sensitivity of 50% (95% confidence interval [CI]: 31-69) and a specificity of 77% (95% CI: 65-87) for identifying fellows who scored poorly on at least one of the three established scales. We developed a novel assessment instrument for use in pediatric fellowship training. The new scale proved feasible and demonstrated internal consistency reliability. Its moderate correlation with other established instruments shows that the novel assessment instrument provides unique, nonredundant information as compared to existing scales. © 2016 Wiley Periodicals, Inc.

  7. Developing of Individual Instrument Performance Anxiety Scale: ValidityReliability Study

    Directory of Open Access Journals (Sweden)

    Esra DALKIRAN

    2016-07-01

    Full Text Available In this study, it is intended to develop a scale unique to our culture, concerning individual instrument performance anxiety of the students who are getting instrument training in the Department of Music Education. In the study, the descriptive research model is used and qualitative research techniques are utilized. The study population consists of the students attending the 23 universities which has Music Education Department. The sample of the study consists of 438 girls and 312 boys, totally 750 students who are studying in the Department of Music Education of randomly selected 10 universities. As a result of the explanatory and confirmatory factor analyses that were performed, a onedimensional structure consisting of 14 items was obtained. Also, t-scores and the coefficient scores of total item correlation concerning the distinguishing power of the items, the difference in the scores of the set of lower and upper 27% was calculated, and it was observed that the items are distinguishing as a result of both analyses. Of the scale, Cronbach's alpha coefficient of internal consistency was calculated as .94, and test-retest reliability coefficient was calculated as .93. As a result, a valid and reliable assessment and evaluation instrument that measures the exam performance anxiety of the students studying in the Department of Music Education, has been developed.

  8. Measuring leprosy-related stigma - a pilot study to validate a toolkit of instruments.

    Science.gov (United States)

    Rensen, Carin; Bandyopadhyay, Sudhakar; Gopal, Pala K; Van Brakel, Wim H

    2011-01-01

    Stigma negatively affects the quality of life of leprosy-affected people. Instruments are needed to assess levels of stigma and to monitor and evaluate stigma reduction interventions. We conducted a validation study of such instruments in Tamil Nadu and West Bengal, India. Four instruments were tested in a 'Community Based Rehabilitation' (CBR) setting, the Participation Scale, Internalised Scale of Mental Illness (ISMI) adapted for leprosy-affected persons, Explanatory Model Interview Catalogue (EMIC) for leprosy-affected and non-affected persons and the General Self-Efficacy (GSE) Scale. We evaluated the following components of validity, construct validity, internal consistency, test-retest reproducibility and reliability to distinguish between groups. Construct validity was tested by correlating instrument scores and by triangulating quantitative and qualitative findings. Reliability was evaluated by comparing levels of stigma among people affected by leprosy and community controls, and among affected people living in CBR project areas and those in non-CBR areas. For the Participation, ISMI and EMIC scores significant differences were observed between those affected by leprosy and those not affected (p = 0.0001), and between affected persons in the CBR and Control group (p < 0.05). The internal consistency of the instruments measured with Cronbach's α ranged from 0.83 to 0.96 and was very good for all instruments. Test-retest reproducibility coefficients were 0.80 for the Participation score, 0.70 for the EMIC score, 0.62 for the ISMI score and 0.50 for the GSE score. The construct validity of all instruments was confirmed. The Participation and EMIC Scales met all validity criteria, but test-retest reproducibility of the ISMI and GSE Scales needs further evaluation with a shorter test-retest interval and longer training and additional adaptations for the latter.

  9. An overview of coefficient alpha and a reliability matrix for estimating adequacy of internal consistency coefficients with psychological research measures.

    Science.gov (United States)

    Ponterotto, Joseph G; Ruckdeschel, Daniel E

    2007-12-01

    The present article addresses issues in reliability assessment that are often neglected in psychological research such as acceptable levels of internal consistency for research purposes, factors affecting the magnitude of coefficient alpha (alpha), and considerations for interpreting alpha within the research context. A new reliability matrix anchored in classical test theory is introduced to help researchers judge adequacy of internal consistency coefficients with research measures. Guidelines and cautions in applying the matrix are provided.

  10. Instruments assessing attitudes toward or capability regarding self-management of osteoarthritis: a systematic review of measurement properties.

    Science.gov (United States)

    Eyles, J P; Hunter, D J; Meneses, S R F; Collins, N J; Dobson, F; Lucas, B R; Mills, K

    2017-08-01

    To make a recommendation on the "best" instrument to assess attitudes toward and/or capabilities regarding self-management of osteoarthritis (OA) based on available measurement property evidence. Electronic searches were performed in MEDLINE, EMBASE, CINAHL and PsychINFO (inception to 27 December 2016). Two reviewers independently rated measurement properties using the Consensus-based Standards for the selection of Health Measurement Instruments (COSMIN) 4-point scale. Best evidence synthesis was determined by considering COSMIN ratings for measurement property results and the level of evidence available for each measurement property of each instrument. Eight studies out of 5653 publications met the inclusion criteria, with eight instruments identified for evaluation: Multidimensional Health Locus of Control (MHLC), Perceived Behavioural Control (PBC), Patient Activation Measure (PAM), Educational Needs Assessment (ENAT), Stages of Change Questionnaire in Osteoarthritis (SCQOA), Effective Consumer Scale (EC-17) and Perceived Efficacy in Patient-Physician Interactions five item (PEPPI-5) and ten item scales. Measurement properties assessed for these instruments included internal consistency (k = 8), structural validity (k = 8), test-retest reliability (k = 2), measurement error (k = 1), hypothesis testing (k = 3) and cross-cultural validity (k = 3). No information was available for content validity, responsiveness or minimal important change (MIC)/minimal important difference (MID). The Dutch PEPPI-5 demonstrated the best measurement property evidence; strong evidence for internal consistency and structural validity but limited evidence for reliability and construct validity. Although PEPPI-5 was identified as having the best measurement properties, overall there is a poor level of evidence currently available concerning measurement properties of instruments to assess attitudes toward and/or capabilities regarding osteoarthritis self-management. Further

  11. Analysis of international and European policy instruments: pollution swapping . Task 2 Service contract "Integrated measures in agriculture to reduce ammonia emissions"

    NARCIS (Netherlands)

    Oenema, O.; Velthof, G.L.

    2007-01-01

    This Report describes the results of Task 2 ‘Analysis of International and European policy instruments’. The aim of this task is to analyze the existing International and European policy instruments aiming at reducing emissions of ammonia, nitrous oxide and methane to the atmosphere and nitrate to

  12. Measurement of Henry's Law Constants Using Internal Standards: A Quantitative GC Experiment for the Instrumental Analysis or Environmental Chemistry Laboratory

    Science.gov (United States)

    Ji, Chang; Boisvert, Susanne M.; Arida, Ann-Marie C.; Day, Shannon E.

    2008-01-01

    An internal standard method applicable to undergraduate instrumental analysis or environmental chemistry laboratory has been designed and tested to determine the Henry's law constants for a series of alkyl nitriles. In this method, a mixture of the analytes and an internal standard is prepared and used to make a standard solution (organic solvent)…

  13. Instrument evaluation no. 11. ESI nuclear model 271 C contamination monitor

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-06-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to he carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This report deals with the ESI Nuclear Model 271 C; a general purpose contamination monitor, comprising a GM tube connected by a coiled extensible cable to a ratemeter

  14. Cultural competence in mental health nursing: validity and internal consistency of the Portuguese version of the multicultural mental health awareness scale-MMHAS.

    Science.gov (United States)

    de Almeida Vieira Monteiro, Ana Paula Teixeira; Fernandes, Alexandre Bastos

    2016-05-17

    Cultural competence is an essential component in rendering effective and culturally responsive services to culturally and ethnically diverse clients. Still, great difficulty exists in assessing the cultural competence of mental health nurses. There are no Portuguese validated measurement instruments to assess cultural competence in mental health nurses. This paper reports a study testing the reliability and validity of the Portuguese version of the Multicultural Mental Health Awareness Scale-MMHAS in a sample of Portuguese nurses. Following a standard forward/backward translation into Portuguese, the adapted version of MMHAS, along with a sociodemographic questionnaire, were applied to a sample of 306 Portuguese nurses (299 males, 77 females; ages 21-68 years, M = 35.43, SD = 9.85 years). A psychometric research design was used with content and construct validity and reliability. Reliability was assessed using internal consistency and item-total correlations. Construct validity was determined using factor analysis. The factor analysis confirmed that the Portuguese version of MMHAS has a three-factor structure of multicultural competencies (Awareness, Knowledge, and Skills) explaining 59.51% of the total variance. Strong content validity and reliability correlations were demonstrated. The Portuguese version of MMHAS has a strong internal consistency, with a Cronbach's alpha of 0.958 for the total scale. The results supported the construct validity and reliability of the Portuguese version of MMHAS, proving that is a reliable and valid measure of multicultural counselling competencies in mental health nursing. The MMHAS Portuguese version can be used to evaluate the effectiveness of multicultural competency training programs in Portuguese-speaking mental health nurses. The scale can also be a useful in future studies of multicultural competencies in Portuguese-speaking nurses.

  15. Magneto-optic Doppler analyzer: a new instrument to measure mesopause winds

    Science.gov (United States)

    Williams, Bifford P.; Tomczyk, Steven

    1996-11-01

    The magneto-optic Doppler analyzer (MODA) is a new type of passive optical instrument that one can use to measure the Doppler shift of the sodium nightglow emitted at approximately 91 km near the mesopause. From this measurement, horizontal wind signatures are inferred. The MODA is based on a sodium vapor magneto-optic filter that provides inherent wavelength stability at a low cost. The instrument has been used to take nightly zonal and meridional wind measurements since October 1994 at Niwot Ridge, Colorado (40 N, 105 W). We obtained an internally consistent wind signal and measured the semidiurnal tide for several seasons.

  16. Towards the development of an outcome instrument for spinal trauma: an international survey of spinal surgeons.

    Science.gov (United States)

    Oner, F Cumhur; Sadiqi, Said; Lehr, A Mechteld; Dvorak, Marcel F; Aarabi, Bizhan; Chapman, Jens R; Fehlings, Michael G; Kandziora, Frank; Rajasekaran, S; Vaccaro, Alexander R

    2015-01-15

    International web-based survey. To identify the most relevant aspects of human function and health status from the perspective of health care professionals involved in the treatment of spinal trauma patients. There is no universally accepted outcome instrument available that is specifically designed or validated for spinal trauma patients, contributing to controversies related to the optimal treatment and evaluation of many types of spinal injuries. Therefore, the AOSpine Knowledge Forum Trauma aims to develop such an instrument using the International Classification of Functioning, Disability, and Health (ICF) as its basis. Experts from the 5 AOSpine International world regions were asked to give their opinion on the relevance of a compilation of 143 ICF categories for spinal trauma patients on a 3-point scale: "not relevant," "probably relevant," or "definitely relevant." The responses were analyzed using frequency analysis. Possible differences in responses between the 5 world regions were analyzed with the Fisher exact test and descriptive statistics. Of the 895 invited AOSpine International members, 150 (16.8%) participated in this study. A total of 13 (9.1%) ICF categories were identified as definitely relevant by more than 80% of the participants. Most of these categories were related to the ICF component "activities and participation" (n = 8), followed by "body functions" (n = 4), and "body structures" (n = 1). Only some minor regional differences were observed in the pattern of answers. More than 80% of an international group of health care professionals experienced in the clinical care of adult spinal trauma patients indicated 13 of 143 ICF categories as definitely relevant to measure outcomes after spinal trauma. This study creates an evidence base to define a core set of ICF categories for outcome measurement in adult spinal trauma patients.

  17. Measuring spirituality and religiosity in clinical research: a systematic review of instruments available in the Portuguese language.

    Science.gov (United States)

    Lucchetti, Giancarlo; Lucchetti, Alessandra Lamas Granero; Vallada, Homero

    2013-01-01

    Despite numerous spirituality and/or religiosity (S/R) measurement tools for use in research worldwide, there is little information on S/R instruments in the Portuguese language. The aim of the present study was to map out the S/R scales available for research in the Portuguese language. Systematic review of studies found in databases. A systematic review was conducted in three phases. Phases 1 and 2: articles in Portuguese, Spanish and English, published up to November 2011, dealing with the Portuguese translation and/or validation of S/R measurement tools for clinical research, were selected from six databases. Phase 3: the instruments were grouped according to authorship, cross-cultural adaptation, internal consistency, concurrent and discriminative validity and test-retest procedures. Twenty instruments were found. Forty-five percent of these evaluated religiosity, 40% spirituality, 10% religious/spiritual coping and 5% S/R. Among these, 90% had been produced in (n = 3) or translated to (n = 15) Brazilian Portuguese and two (10%) solely to European Portuguese. Nevertheless, the majority of the instruments had not undergone in-depth psychometric analysis. Only 40% of the instruments presented concurrent validity, 45% discriminative validity and 15% a test-retest procedure. The characteristics of each instrument were analyzed separately, yielding advantages, disadvantages and psychometric properties. Currently, 20 instruments for measuring S/R are available in the Portuguese language. Most have been translated (n = 15) or developed (n = 3) in Brazil and present good internal consistency. Nevertheless, few instruments have been assessed regarding all their psychometric qualities.

  18. Measuring spirituality and religiosity in clinical research: a systematic review of instruments available in the Portuguese language

    Directory of Open Access Journals (Sweden)

    Giancarlo Lucchetti

    Full Text Available CONTEXT AND OBJECTIVES Despite numerous spirituality and/or religiosity (S/R measurement tools for use in research worldwide, there is little information on S/R instruments in the Portuguese language. The aim of the present study was to map out the S/R scales available for research in the Portuguese language. DESIGN AND SETTING Systematic review of studies found in databases. METHODS A systematic review was conducted in three phases. Phases 1 and 2: articles in Portuguese, Spanish and English, published up to November 2011, dealing with the Portuguese translation and/or validation of S/R measurement tools for clinical research, were selected from six databases. Phase 3: the instruments were grouped according to authorship, cross-cultural adaptation, internal consistency, concurrent and discriminative validity and test-retest procedures. RESULTS Twenty instruments were found. Forty-five percent of these evaluated religiosity, 40% spirituality, 10% religious/spiritual coping and 5% S/R. Among these, 90% had been produced in (n = 3 or translated to (n = 15 Brazilian Portuguese and two (10% solely to European Portuguese. Nevertheless, the majority of the instruments had not undergone in-depth psychometric analysis. Only 40% of the instruments presented concurrent validity, 45% discriminative validity and 15% a test-retest procedure. The characteristics of each instrument were analyzed separately, yielding advantages, disadvantages and psychometric properties. CONCLUSION Currently, 20 instruments for measuring S/R are available in the Portuguese language. Most have been translated (n = 15 or developed (n = 3 in Brazil and present good internal consistency. Nevertheless, few instruments have been assessed regarding all their psychometric qualities.

  19. Internal Consistency of the easyCBM© CCSS Reading Measures: Grades 3-8. Technical Report #1407

    Science.gov (United States)

    Guerreiro, Meg; Alonzo, Julie; Tindal, Gerald

    2014-01-01

    This technical report documents findings from a study of the internal consistency and split-half reliability of the easyCBM© CCSS Reading measures, grades 3-8. Data, drawn from an extant data set gathered in school year 2013-2014, include scores from over 150,000 students' fall and winter benchmark assessments. Findings suggest that the easyCBM©…

  20. How Well Does the Sum Score Summarize the Test? Summability as a Measure of Internal Consistency

    NARCIS (Netherlands)

    Goeman, J.J.; De, Jong N.H.

    2018-01-01

    Many researchers use Cronbach's alpha to demonstrate internal consistency, even though it has been shown numerous times that Cronbach's alpha is not suitable for this. Because the intention of questionnaire and test constructers is to summarize the test by its overall sum score, we advocate

  1. Instruments Measuring Integrated Care: A Systematic Review of Measurement Properties.

    Science.gov (United States)

    Bautista, Mary Ann C; Nurjono, Milawaty; Lim, Yee Wei; Dessers, Ezra; Vrijhoef, Hubertus Jm

    2016-12-01

    -centered care (49%); fewer studies measured care continuity/comprehensive care (15%) and care coordination/case management (3%). We mapped 84% of the measured constructs to the clinical integration domain of the RMIC, with fewer constructs related to the domains of professional (3.7%), organizational (3.4%), and functional (0.5%) integration. Only 8% of the instruments were mapped to a combination of domains; none were mapped exclusively to the system or normative integration domains. The majority of instruments were administered to either patients (60%) or health care providers (20%). Of the measurement properties, responsiveness (4%), measurement error (7%), and criterion (12%) and cross-cultural validity (14%) were less commonly reported. We found measurement properties. Only a minority of index instruments showed strong evidence of positive findings for internal consistency (15%), content validity (19%), and structural validity (7%); with moderate evidence of positive findings for internal consistency (14%) and construct validity (14%). Our results suggest that the quality of measurement properties of instruments measuring integrated care is in need of improvement with the less-studied constructs and domains to become part of newly developed instruments. © 2016 Milbank Memorial Fund.

  2. Instruments Measuring Integrated Care: A Systematic Review of Measurement Properties

    Science.gov (United States)

    BAUTISTA, MARY ANN C.; NURJONO, MILAWATY; DESSERS, EZRA; VRIJHOEF, HUBERTUS JM

    2016-01-01

    integration (33%) and patient‐centered care (49%); fewer studies measured care continuity/comprehensive care (15%) and care coordination/case management (3%). We mapped 84% of the measured constructs to the clinical integration domain of the RMIC, with fewer constructs related to the domains of professional (3.7%), organizational (3.4%), and functional (0.5%) integration. Only 8% of the instruments were mapped to a combination of domains; none were mapped exclusively to the system or normative integration domains. The majority of instruments were administered to either patients (60%) or health care providers (20%). Of the measurement properties, responsiveness (4%), measurement error (7%), and criterion (12%) and cross‐cultural validity (14%) were less commonly reported. We found measurement properties. Only a minority of index instruments showed strong evidence of positive findings for internal consistency (15%), content validity (19%), and structural validity (7%); with moderate evidence of positive findings for internal consistency (14%) and construct validity (14%). Conclusions Our results suggest that the quality of measurement properties of instruments measuring integrated care is in need of improvement with the less‐studied constructs and domains to become part of newly developed instruments. PMID:27995711

  3. The U.S./IAEA Workshop on Software Sustainability for Safeguards Instrumentation: Report to the NNSA DOE Office of International Nuclear Safeguards (NA-241)

    Energy Technology Data Exchange (ETDEWEB)

    Pepper, Susan E. [Brookhaven National Lab. (BNL), Upton, NY (United States); Pickett, Chris A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Queirolo, Al [Brookhaven National Lab. (BNL), Upton, NY (United States); Bachner, Katherine M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Worrall, Louise G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-04-07

    The U.S Department of Energy (DOE) National Nuclear Security Administration (NNSA) Next Generation Safeguards Initiative (NGSI) and the International Atomic Energy Agency (IAEA) convened a workshop on Software Sustainability for Safeguards Instrumentation in Vienna, Austria, May 6-8, 2014. Safeguards instrumentation software must be sustained in a changing environment to ensure existing instruments can continue to perform as designed, with improved security. The approaches to the development and maintenance of instrument software used in the past may not be the best model for the future and, therefore, the organizers’ goal was to investigate these past approaches and to determine an optimal path forward. The purpose of this report is to provide input for the DOE NNSA Office of International Nuclear Safeguards (NA-241) and other stakeholders that can be utilized when making decisions related to the development and maintenance of software used in the implementation of international nuclear safeguards. For example, this guidance can be used when determining whether to fund the development, upgrade, or replacement of a particular software product. The report identifies the challenges related to sustaining software, and makes recommendations for addressing these challenges, supported by summaries and detailed notes from the workshop discussions. In addition the authors provide a set of recommendations for institutionalizing software sustainability practices in the safeguards community. The term “software sustainability” was defined for this workshop as ensuring that safeguards instrument software and algorithm functionality can be maintained efficiently throughout the instrument lifecycle, without interruption and providing the ability to continue to improve that software as needs arise.

  4. The U.S./IAEA Workshop on Software Sustainability for Safeguards Instrumentation: Report to the NNSA DOE Office of International Nuclear Safeguards (NA-241)

    International Nuclear Information System (INIS)

    Pepper, Susan E.; Pickett, Chris A.; Queirolo, Al; Bachner, Katherine M.; Worrall, Louise G.

    2015-01-01

    The U.S Department of Energy (DOE) National Nuclear Security Administration (NNSA) Next Generation Safeguards Initiative (NGSI) and the International Atomic Energy Agency (IAEA) convened a workshop on Software Sustainability for Safeguards Instrumentation in Vienna, Austria, May 6-8, 2014. Safeguards instrumentation software must be sustained in a changing environment to ensure existing instruments can continue to perform as designed, with improved security. The approaches to the development and maintenance of instrument software used in the past may not be the best model for the future and, therefore, the organizers' goal was to investigate these past approaches and to determine an optimal path forward. The purpose of this report is to provide input for the DOE NNSA Office of International Nuclear Safeguards (NA-241) and other stakeholders that can be utilized when making decisions related to the development and maintenance of software used in the implementation of international nuclear safeguards. For example, this guidance can be used when determining whether to fund the development, upgrade, or replacement of a particular software product. The report identifies the challenges related to sustaining software, and makes recommendations for addressing these challenges, supported by summaries and detailed notes from the workshop discussions. In addition the authors provide a set of recommendations for institutionalizing software sustainability practices in the safeguards community. The term ''software sustainability'' was defined for this workshop as ensuring that safeguards instrument software and algorithm functionality can be maintained efficiently throughout the instrument lifecycle, without interruption and providing the ability to continue to improve that software as needs arise.

  5. International legal instruments promoting synergy's in nuclear safety, security and safeguards: myth of reality?

    International Nuclear Information System (INIS)

    Vasmant, A.

    2009-01-01

    The purpose of this article is to assess the existing synergies between nuclear safety, nuclear security and non-proliferation/safeguards resulting from the adoption of international legal instruments. Keeping in mind that a synergy is the extra success achieved by two or more elements of a system working together instead of on their own, this paper will try to evaluate the possibility of a so-called '3 S' approach to optimize the benefits so defined. to achieve this, Part 1 focuses on the history of the three regimes and their major features, while Part 2, 3 and 4 explore the various benefits of, limits to, synergies between the nuclear safety, nuclear security and safeguards regimes. Part 5 describes the potential '3 S' approach in international nuclear law. (N.C.)

  6. Link between self-consistent pressure profiles and electron internal transport barriers in tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Razumova, K A [Nuclear Fusion Institute, RRC ' Kurchatov Institute' , 123182 Moscow (Russian Federation); Andreev, V F [Nuclear Fusion Institute, RRC ' Kurchatov Institute' , 123182 Moscow (Russian Federation); Donne, A J H [FOM-Institute for Plasma Physics Rijnhuizen, Association EURATOM-FOM, partner in the Trilateral Euregio Cluster, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Hogeweij, G M D [FOM-Institute for Plasma Physics Rijnhuizen, Association EURATOM-FOM, partner in the Trilateral Euregio Cluster, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Lysenko, S E [Nuclear Fusion Institute, RRC ' Kurchatov Institute' , 123182 Moscow (Russian Federation); Shelukhin, D A [Nuclear Fusion Institute, RRC ' Kurchatov Institute' , 123182 Moscow (Russian Federation); Spakman, G W [FOM-Institute for Plasma Physics Rijnhuizen, Association EURATOM-FOM, partner in the Trilateral Euregio Cluster, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Vershkov, V A [Nuclear Fusion Institute, RRC ' Kurchatov Institute' , 123182 Moscow (Russian Federation); Zhuravlev, V A [Nuclear Fusion Institute, RRC ' Kurchatov Institute' , 123182 Moscow (Russian Federation)

    2006-09-15

    Tokamak plasmas have a tendency to self-organization: the plasma pressure profiles obtained in different operational regimes and even in various tokamaks may be represented by a single typical curve, called the self-consistent pressure profile. About a decade ago local zones with enhanced confinement were discovered in tokamak plasmas. These zones are referred to as internal transport barriers (ITBs) and they can act on the electron and/or ion fluid. Here the pressure gradients can largely exceed the gradients dictated by profile consistency. So the existence of ITBs seems to be in contradiction with the self-consistent pressure profiles (this is also often referred to as profile resilience or profile stiffness). In this paper we will discuss the interplay between profile consistency and ITBs. A summary of the cumulative information obtained from T-10, RTP and TEXTOR is given, and a coherent explanation of the main features of the observed phenomena is suggested. Both phenomena, the self-consistent profile and ITB, are connected with the density of rational magnetic surfaces, where the turbulent cells are situated. The distance between these cells determines the level of their interaction, and therefore the level of the turbulent transport. This process regulates the plasma pressure profile. If the distance is wide, the turbulent flux may be diminished and the ITB may be formed. In regions with rarefied surfaces the steeper pressure gradients are possible without instantaneously inducing pressure driven instabilities, which force the profiles back to their self-consistent shapes. Also it can be expected that the ITB region is wider for lower dq/d{rho} (more rarefied surfaces)

  7. Planck 2013 results. XXXI. Consistency of the Planck data

    CERN Document Server

    Ade, P A R; Ashdown, M; Aumont, J; Baccigalupi, C; Banday, A.J; Barreiro, R.B; Battaner, E; Benabed, K; Benoit-Levy, A; Bernard, J.P; Bersanelli, M; Bielewicz, P; Bond, J.R; Borrill, J; Bouchet, F.R; Burigana, C; Cardoso, J.F; Catalano, A; Challinor, A; Chamballu, A; Chiang, H.C; Christensen, P.R; Clements, D.L; Colombi, S; Colombo, L.P.L; Couchot, F; Coulais, A; Crill, B.P; Curto, A; Cuttaia, F; Danese, L; Davies, R.D; Davis, R.J; de Bernardis, P; de Rosa, A; de Zotti, G; Delabrouille, J; Desert, F.X; Dickinson, C; Diego, J.M; Dole, H; Donzelli, S; Dore, O; Douspis, M; Dupac, X; Ensslin, T.A; Eriksen, H.K; Finelli, F; Forni, O; Frailis, M; Fraisse, A A; Franceschi, E; Galeotta, S; Ganga, K; Giard, M; Gonzalez-Nuevo, J; Gorski, K.M.; Gratton, S.; Gregorio, A; Gruppuso, A; Gudmundsson, J E; Hansen, F.K; Hanson, D; Harrison, D; Henrot-Versille, S; Herranz, D; Hildebrandt, S.R; Hivon, E; Hobson, M; Holmes, W.A.; Hornstrup, A; Hovest, W.; Huffenberger, K.M; Jaffe, T.R; Jaffe, A.H; Jones, W.C; Keihanen, E; Keskitalo, R; Knoche, J; Kunz, M; Kurki-Suonio, H; Lagache, G; Lahteenmaki, A; Lamarre, J.M; Lasenby, A; Lawrence, C.R; Leonardi, R; Leon-Tavares, J; Lesgourgues, J; Liguori, M; Lilje, P.B; Linden-Vornle, M; Lopez-Caniego, M; Lubin, P.M; Macias-Perez, J.F; Maino, D; Mandolesi, N; Maris, M; Martin, P.G; Martinez-Gonzalez, E; Masi, S; Matarrese, S; Mazzotta, P; Meinhold, P.R; Melchiorri, A; Mendes, L; Mennella, A; Migliaccio, M; Mitra, S; Miville-Deschenes, M.A; Moneti, A; Montier, L; Morgante, G; Mortlock, D; Moss, A; Munshi, D; Murphy, J A; Naselsky, P; Nati, F; Natoli, P; Norgaard-Nielsen, H.U; Noviello, F; Novikov, D; Novikov, I; Oxborrow, C.A; Pagano, L; Pajot, F; Paoletti, D; Partridge, B; Pasian, F; Patanchon, G; Pearson, D; Pearson, T.J; Perdereau, O; Perrotta, F; Piacentini, F; Piat, M; Pierpaoli, E; Pietrobon, D; Plaszczynski, S; Pointecouteau, E; Polenta, G; Ponthieu, N; Popa, L; Pratt, G.W; Prunet, S; Puget, J.L; Rachen, J.P; Reinecke, M; Remazeilles, M; Renault, C; Ricciardi, S.; Ristorcelli, I; Rocha, G.; Roudier, G; Rubino-Martin, J.A; Rusholme, B; Sandri, M; Scott, D; Stolyarov, V; Sudiwala, R; Sutton, D; Suur-Uski, A.S; Sygnet, J.F; Tauber, J.A; Terenzi, L; Toffolatti, L; Tomasi, M; Tristram, M; Tucci, M; Valenziano, L; Valiviita, J; Van Tent, B; Vielva, P; Villa, F; Wade, L.A; Wandelt, B.D; Wehus, I K; White, S D M; Yvon, D; Zacchei, A; Zonca, A

    2014-01-01

    The Planck design and scanning strategy provide many levels of redundancy that can be exploited to provide tests of internal consistency. One of the most important is the comparison of the 70 GHz (amplifier) and 100 GHz (bolometer) channels. Based on different instrument technologies, with feeds located differently in the focal plane, analysed independently by different teams using different software, and near the minimum of diffuse foreground emission, these channels are in effect two different experiments. The 143 GHz channel has the lowest noise level on Planck, and is near the minimum of unresolved foreground emission. In this paper, we analyse the level of consistency achieved in the 2013 Planck data. We concentrate on comparisons between the 70, 100, and 143 GHz channel maps and power spectra, particularly over the angular scales of the first and second acoustic peaks, on maps masked for diffuse Galactic emission and for strong unresolved sources. Difference maps covering angular scales from 8°...

  8. ICFA: Instrumentation school

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1987-10-15

    74 students, including 45 from developing countries, ten lecturers and nine laboratory instructors participated in the novel instrumentation school held in June at the International Centre for Theoretical Physics (ICTP), Trieste, Italy, sponsored by ICTP and arranged through the Instrumentation Panel of the International Committee for Future Accelerators (ICF). During the two weeks of the course, students had the chance to construct and test a proportional chamber, measure the lifetime of cosmic ray muons, operate and analyse the performance of an 8-wire imaging drift chamber, or study noise and signal processing using a silicon photodiode.

  9. ICFA: Instrumentation school

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    74 students, including 45 from developing countries, ten lecturers and nine laboratory instructors participated in the novel instrumentation school held in June at the International Centre for Theoretical Physics (ICTP), Trieste, Italy, sponsored by ICTP and arranged through the Instrumentation Panel of the International Committee for Future Accelerators (ICF). During the two weeks of the course, students had the chance to construct and test a proportional chamber, measure the lifetime of cosmic ray muons, operate and analyse the performance of an 8-wire imaging drift chamber, or study noise and signal processing using a silicon photodiode

  10. Psychometric Properties of an Instrument Derived from the Intentional Relationship Model: The SelfEfficacy for Recognizing Clients’ Interpersonal Characteristics (N-SERIC

    Directory of Open Access Journals (Sweden)

    Victoria C. Ritter

    2018-04-01

    Full Text Available Background: The Intentional Relationship Model conceptualizes the therapeutic use of self in occupational therapy. To increase motivation for and success in establishing therapeutic relationships, therapists need self-efficacy for using the self in therapeutic practice. However, attempts to combine this model with self-efficacy theory are rare, and instruments by which to measure self-efficacy for therapeutic use of self are in a developing stage. This study aimed to examine the factor structure and internal consistency of the Norwegian Self-Efficacy for Recognizing Interpersonal Characteristics (N-SERIC. Methods: Occupational therapy students (n = 100 from two education programs completed the instrument and sociodemographic information. The factor structure was examined with Principal Components Analysis (PCA, and internal consistency was assessed with Cronbach’s α and inter-item correlations. Results: The PCA revealed that all N-SERIC items belonged to the same latent factor, with factor loadings ranging between 0.75 and 0.89. The internal consistency of the scale items was high (Cronbach’s α = 0.96. Conclusions: The N-SERIC scale is unidimensional and the items have very high internal consistency. Thus, the scale sum score can be useful for occupational therapy research and audits focusing on interpersonal aspects of practice.

  11. Psychometric Properties of The Fertility Quality of Life Instrument in Infertile Iranian Women

    Directory of Open Access Journals (Sweden)

    Saman Maroufizadeh

    2016-11-01

    Full Text Available Background: Infertility and its treatment can have a considerable effect on a person’s quality of life (QoL. The Fertility QoL (FertiQoL questionnaire is currently the most frequently used instrument to measure QoL in people with fertility problems. This study aims to examine the reliability and validity of the FertiQoL in infertile Iranian women. Materials and Methods: This cross-sectional study included 155 women with fertility problems in a referral fertility clinic in Tehran, Iran from January to March 2014. A battery of instruments was used: FertiQoL, Satisfaction with Life Scale (SWLS, Hospital Anxiety and Depression Scale (HADS, and a demographic questionnaire. Construct validity of the scale was evaluated using confirmatory factor analysis (CFA. We assessed internal consistency with Cronbach’s alpha and convergent validity was examined by correlating the FertiQoL with SWLS and HADS. Results: The results of the CFA generally supported the four-factor model of Core FertiQoL and two-factor model of Treatment FertiQoL. Both FertiQoL modules and their subscales revealed acceptable internal consistency that ranged from 0.643 to 0.911. However, the FertiQoL might be improved if Q15 and T2 items were removed from the scale. These items had low loadings on the Relational and Environment factors which decreased their internal consistency. The FertiQoL and their subscales significantly correlated with both SWLS and HADS, which confirmed convergent validity. Conclusion: The Persian version of the FertiQoL is a valid, reliable instrument to measure QoL in infertile women and seems to perform as well as the original English Version.

  12. Quality of prenatal care questionnaire: instrument development and testing.

    Science.gov (United States)

    Heaman, Maureen I; Sword, Wendy A; Akhtar-Danesh, Noori; Bradford, Amanda; Tough, Suzanne; Janssen, Patricia A; Young, David C; Kingston, Dawn A; Hutton, Eileen K; Helewa, Michael E

    2014-06-03

    Utilization indices exist to measure quantity of prenatal care, but currently there is no published instrument to assess quality of prenatal care. The purpose of this study was to develop and test a new instrument, the Quality of Prenatal Care Questionnaire (QPCQ). Data for this instrument development study were collected in five Canadian cities. Items for the QPCQ were generated through interviews with 40 pregnant women and 40 health care providers and a review of prenatal care guidelines, followed by assessment of content validity and rating of importance of items. The preliminary 100-item QPCQ was administered to 422 postpartum women to conduct item reduction using exploratory factor analysis. The final 46-item version of the QPCQ was then administered to another 422 postpartum women to establish its construct validity, and internal consistency and test-retest reliability. Exploratory factor analysis reduced the QPCQ to 46 items, factored into 6 subscales, which subsequently were validated by confirmatory factor analysis. Construct validity was also demonstrated using a hypothesis testing approach; there was a significant positive association between women's ratings of the quality of prenatal care and their satisfaction with care (r = 0.81). Convergent validity was demonstrated by a significant positive correlation (r = 0.63) between the "Support and Respect" subscale of the QPCQ and the "Respectfulness/Emotional Support" subscale of the Prenatal Interpersonal Processes of Care instrument. The overall QPCQ had acceptable internal consistency reliability (Cronbach's alpha = 0.96), as did each of the subscales. The test-retest reliability result (Intra-class correlation coefficient = 0.88) indicated stability of the instrument on repeat administration approximately one week later. Temporal stability testing confirmed that women's ratings of their quality of prenatal care did not change as a result of giving birth or between the early postpartum

  13. Quality of prenatal care questionnaire: instrument development and testing

    Science.gov (United States)

    2014-01-01

    Background Utilization indices exist to measure quantity of prenatal care, but currently there is no published instrument to assess quality of prenatal care. The purpose of this study was to develop and test a new instrument, the Quality of Prenatal Care Questionnaire (QPCQ). Methods Data for this instrument development study were collected in five Canadian cities. Items for the QPCQ were generated through interviews with 40 pregnant women and 40 health care providers and a review of prenatal care guidelines, followed by assessment of content validity and rating of importance of items. The preliminary 100-item QPCQ was administered to 422 postpartum women to conduct item reduction using exploratory factor analysis. The final 46-item version of the QPCQ was then administered to another 422 postpartum women to establish its construct validity, and internal consistency and test-retest reliability. Results Exploratory factor analysis reduced the QPCQ to 46 items, factored into 6 subscales, which subsequently were validated by confirmatory factor analysis. Construct validity was also demonstrated using a hypothesis testing approach; there was a significant positive association between women’s ratings of the quality of prenatal care and their satisfaction with care (r = 0.81). Convergent validity was demonstrated by a significant positive correlation (r = 0.63) between the “Support and Respect” subscale of the QPCQ and the “Respectfulness/Emotional Support” subscale of the Prenatal Interpersonal Processes of Care instrument. The overall QPCQ had acceptable internal consistency reliability (Cronbach’s alpha = 0.96), as did each of the subscales. The test-retest reliability result (Intra-class correlation coefficient = 0.88) indicated stability of the instrument on repeat administration approximately one week later. Temporal stability testing confirmed that women’s ratings of their quality of prenatal care did not change as a result of giving

  14. Developing and testing an instrument to measure the presence of conditions for successful implementation of quality improvement collaboratives.

    Science.gov (United States)

    Dückers, Michel L A; Wagner, Cordula; Groenewegen, Peter P

    2008-08-11

    In quality improvement collaboratives (QICs) teams of practitioners from different health care organizations are brought together to systematically improve an aspect of patient care. Teams take part in a series of meetings to learn about relevant best practices, quality methods and change ideas, and share experiences in making changes in their own local setting. The purpose of this study was to develop an instrument for measuring team organization, external change agent support and support from the team's home institution in a Dutch national improvement and dissemination programme for hospitals based on several QICs. The exploratory methodological design included two phases: a) content development and assessment, resulting in an instrument with 15 items, and b) field testing (N = 165). Internal consistency reliability was tested via Cronbach's alpha coefficient. Principal component analyses were used to identify underlying constructs. Tests of scaling assumptions according to the multi trait/multi-item matrix, were used to confirm the component structure. Three components were revealed, explaining 65% of the variability. The components were labelled 'organizational support', 'team organization' and 'external change agent support'. One item not meeting item-scale criteria was removed. This resulted in a 14 item instrument. Scale reliability ranged from 0.77 to 0.91. Internal item consistency and divergent validity were satisfactory. On the whole, the instrument appears to be a promising tool for assessing team organization and internal and external support during QIC implementation. The psychometric properties were good and warrant application of the instrument for the evaluation of the national programme and similar improvement programmes.

  15. Developing and testing an instrument to measure the presence of conditions for successful implementation of quality improvement collaboratives

    Directory of Open Access Journals (Sweden)

    Wagner Cordula

    2008-08-01

    Full Text Available Abstract Background In quality improvement collaboratives (QICs teams of practitioners from different health care organizations are brought together to systematically improve an aspect of patient care. Teams take part in a series of meetings to learn about relevant best practices, quality methods and change ideas, and share experiences in making changes in their own local setting. The purpose of this study was to develop an instrument for measuring team organization, external change agent support and support from the team's home institution in a Dutch national improvement and dissemination programme for hospitals based on several QICs. Methods The exploratory methodological design included two phases: a content development and assessment, resulting in an instrument with 15 items, and b field testing (N = 165. Internal consistency reliability was tested via Cronbach's alpha coefficient. Principal component analyses were used to identify underlying constructs. Tests of scaling assumptions according to the multi trait/multi-item matrix, were used to confirm the component structure. Results Three components were revealed, explaining 65% of the variability. The components were labelled 'organizational support', 'team organization' and 'external change agent support'. One item not meeting item-scale criteria was removed. This resulted in a 14 item instrument. Scale reliability ranged from 0.77 to 0.91. Internal item consistency and divergent validity were satisfactory. Conclusion On the whole, the instrument appears to be a promising tool for assessing team organization and internal and external support during QIC implementation. The psychometric properties were good and warrant application of the instrument for the evaluation of the national programme and similar improvement programmes.

  16. New methods of magnet-based instrumentation for NOTES.

    Science.gov (United States)

    Magdeburg, Richard; Hauth, Daniel; Kaehler, Georg

    2013-12-01

    Laparoscopic surgery has displaced open surgery as the standard of care for many clinical conditions. NOTES has been described as the next surgical frontier with the objective of incision-free abdominal surgery. The principal challenge of NOTES procedures is the loss of triangulation and instrument rigidity, which is one of the fundamental concepts of laparoscopic surgery. To overcome these problems necessitates the development of new instrumentation. material and methods: We aimed to assess the use of a very simple combination of internal and external magnets that might allow the vigorous multiaxial traction/counter-traction required in NOTES procedures. The magnet retraction system consisted of an external magnetic assembly and either small internal magnets attached by endoscopic clips to the designated tissue (magnet-clip-approach) or an endoscopic grasping forceps in a magnetic deflector roll (magnet-trocar-approach). We compared both methods regarding precision, time and efficacy by performing transgastric partial uterus resections with better results for the magnet-trocar-approach. This proof-of-principle animal study showed that the combination of external and internal magnets generates sufficient coupling forces at clinically relevant abdominal wall thicknesses, making them suitable for use and evaluation in NOTES procedures, and provides the vigorous multiaxial traction/counter-traction required by the lack of additional abdominal trocars.

  17. Rare earths analysis of rock samples by instrumental neutron activation analysis, internal standard method

    International Nuclear Information System (INIS)

    Silachyov, I.

    2016-01-01

    The application of instrumental neutron activation analysis for the determination of long-lived rare earth elements (REE) in rock samples is considered in this work. Two different methods are statistically compared: the well established external standard method carried out using standard reference materials, and the internal standard method (ISM), using Fe, determined through X-ray fluorescence analysis, as an element-comparator. The ISM proved to be the more precise method for a wide range of REE contents and can be recommended for routine practice. (author)

  18. Instrumentation in elementary particle physics

    Energy Technology Data Exchange (ETDEWEB)

    Fabjan, C W [European Organization for Nuclear Research, Geneva (Switzerland); Pilcher, J E [Chicago Univ., IL (United States); eds.

    1988-01-01

    The first International Committee for Future Accelerators Instrumentation School was held at the International Centre for Theoretical Physics, Trieste, Italy from 8 to 19 June 1987. The School was attended by 74 students of whom 45 were from developing countries, 10 lecturers and 9 laboratory instructors. The next generation of elementary particle physics experiments would depend vitally on new ideas in instrumentation. This is a field where creativity and imagination play a major role and large budgets are not a prerequisite. One of the unique features was the presentation of four laboratory experiments using modern techniques and instrumentation. Refs, figs and tabs.

  19. Instrumentation in elementary particle physics

    International Nuclear Information System (INIS)

    Fabjan, C.W.; Pilcher, J.E.

    1988-01-01

    The first International Committee for Future Accelerators Instrumentation School was held at the International Centre for Theoretical Physics, Trieste, Italy from 8 to 19 June 1987. The School was attended by 74 students of whom 45 were from developing countries, 10 lecturers and 9 laboratory instructors. The next generation of elementary particle physics experiments would depend vitally on new ideas in instrumentation. This is a field where creativity and imagination play a major role and large budgets are not a prerequisite. One of the unique features was the presentation of four laboratory experiments using modern techniques and instrumentation. Refs, figs and tabs

  20. Providing Consistent (A)ATSR Solar Channel Radiometry for Climate Studies

    Science.gov (United States)

    Smith, D.; Latter, B. G.; Poulsen, C.

    2012-04-01

    Data from the solar reflectance channels of the Along Track Scanning Radiometer (ATSR) series of instruments are being used in applications for monitoring trends in clouds and aerosols. In order to provide quantitative information, the radiometric calibrations of the sensors must be consistent, stable and ideally traced to international standards. This paper describes the methods used to monitor the calibrations of the ATSR instruments to provide consistent Level 1b radiometric data sets. Comparisons of the in-orbit calibrations are made by reference to data from quasi stable sites such as DOME-C in Antarctica or Saharan Desert sites. Comparisons are performed either by time coincident match-ups of the radiometric data for sensors having similar spectral bands and view/solar geometry and overpass times as for AATSR and MERIS; or via a reference BRDF model derived from averages of measurements over the site from a reference sensor where there is limited or no temporal overlap (e.g. MODIS-Aqua, ATSR-1 and ATSR-2). The results of the intercomparisons provide values of the long term calibration drift and systematic biases between the sensors. Look-up tables based on smoothed averages of the drift measurements are used to provide the corrections to Level 1b data. The uncertainty budgets for the comparisons are provided. It is also possible to perform comparisons of measurements against high spectral resolution instruments that are co-located on the same platform, i.e. AATSR/SCIA on ENVISAT and ATSR-2/GOME on ERS-2. The comparisons are performed by averaging the spectrometer data to the spectral response of the filter radiometer, and averaging the radiometer data to the spatial resolution of the spectrometer. In this paper, the authors present the results of the inter-comparisons to achieve a consistent calibration for the solar channels of the complete ATSR dataset. An assessment of the uncertainties associated with the techniques will be discussed. The impacts of the

  1. Development and initial validation of the internalization of Asian American stereotypes scale.

    Science.gov (United States)

    Shen, Frances C; Wang, Yu-Wei; Swanson, Jane L

    2011-07-01

    This research consists of four studies on the initial reliability and validity of the Internalization of Asian American Stereotypes Scale (IAASS), a self-report instrument that measures the degree Asian Americans have internalized racial stereotypes about their own group. The results from the exploratory and confirmatory factor analyses support a stable four-factor structure of the IAASS: Difficulties with English Language Communication, Pursuit of Prestigious Careers, Emotional Reservation, and Expected Academic Success. Evidence for concurrent and discriminant validity is presented. High internal-consistency and test-retest reliability estimates are reported. A discussion of how this scale can contribute to research and practice regarding internalized stereotyping among Asian Americans is provided.

  2. Modernization of control instrumentation and security of reactor IAN - R1

    International Nuclear Information System (INIS)

    Gonzalez, J. M.

    1993-01-01

    The program to modernize IAN-R1 research reactor control and safety instrumentation has been carried out considering two main aspects: updating safety philosophy requirements and acquiring the newest reactor control instrumentation controlled by computer, following the present criteria internationally recognized, for safety and reliable reactor operations and the latest developments of nuclear electronic technology. The new IAN-R1 reactor instrumentation consist of two wide range neutron monitoring channels, commanded by microprocessor a data acquisition system and reactor control, (controlled by computers). The reactor control desk is providing through two displays; all safety and control signals to the reactor operators; furthermore some signals like reactor power, safety and period signals are also showed on digital bar graphics, which are hard wired directly from the neutron monitoring channels

  3. Status of safeguards instrumentation

    International Nuclear Information System (INIS)

    Higinbotham, W.A.

    The International Atomic Energy Agency is performing safeguards at some nuclear power reactors, 50 bulk processing facilities, and 170 research facilities. Its verification activities require the use of instruments to measure nuclear materials and of surveillance instruments to maintain continuity of knowledge of the locations of nuclear materials. Instruments that are in use and under development to measure weight, volume, concentration, and isotopic composition of nuclear materials, and the major surveillance instruments, are described in connection with their uses at representative nuclear facilities. The current status of safeguards instrumentation and the needs for future development are discussed

  4. Specification of requirements for upgrades using digital instrument and control systems. Report prepared within the framework of the international working group on nuclear power plant control and instrumentation

    International Nuclear Information System (INIS)

    1999-01-01

    The need to develop good specifications of requirements for instrument and control (I and C) systems applies throughout the world and is becoming more and more important as more upgrades are planned. Better guidance on how to develop good requirements specifications would support safer, more effective and more economical refits and upgrades. The need for this was pointed out by the IAEA International Working Group on Nuclear Power Plant Control and Instrumentation (IWG-NPPCI). This report is the result of a series of advisory and consultants meetings held by the IAEA in 1997 and 1998 in Vienna. The scope of the activities described covers a methodology for the determination of requirements and the development of the necessary specifications and plans needed through the life-cycle of digital instrumentation and control systems. It is restricted to technical aspects and indicates subjects which should be included in specifications and plans at different phases

  5. Evaluation of construct and criterion validity for the 'Liverpool Osteoarthritis in Dogs' (LOAD clinical metrology instrument and comparison to two other instruments.

    Directory of Open Access Journals (Sweden)

    Myles Benjamin Walton

    Full Text Available To test the 'Liverpool Osteoarthritis in Dogs' (LOAD questionnaire for construct and criterion validity, and to similarly test the Helsinki Chronic Pain Index (HCPI and the Canine Brief Pain Inventory (CBPI.Prospective Study.222 dogs with osteoarthritis.Osteoarthritis was diagnosed in a cohort of dogs on the basis of clinical history and orthopedic examination. Force-platform analysis was performed and a "symmetry index" for peak vertical force (PVF was calculated. Owners completed LOAD, CBPI and HCPI instruments. As a test of construct validity, inter-instrument correlations were calculated. As a test of criterion validity, the correlations between instrument scores and PVF symmetry scores were calculated. Additionally, internal consistency of all instruments was calculated and compared to those previously reported. Factor analysis is reported for the first time for LOAD, and is compared to that previously reported for CBPI and HCPI.Significant moderate correlations were found between all instruments, implying construct validity for all instruments. Significant weak correlations were found between LOAD scores and PVF symmetry index, and between CBPI scores and PVF symmetry index.LOAD is an owner-completed clinical metrology instrument that can be recommended for the measurement of canine osteoarthritis. It is convenient to use, validated and, as demonstrated here for the first time, has a correlation with force-platform data.

  6. [Development of an evaluation instrument for service quality in nursing homes].

    Science.gov (United States)

    Lee, Jia; Ji, Eun Sun

    2011-08-01

    The purposes of this study were to identify the factors influencing service quality in nursing homes, and to develop an evaluation instrument for service quality. A three-phase process was employed for the study. 1) The important factors to evaluate the service quality in nursing homes were identified through a literature review, panel discussion and focus group interview, 2) the evaluation instrument was developed, and 3) validity and reliability of the study instrument were tested by factor analysis, Pearson correlation coefficient, Cronbach's α and Cohen's Kappa. Factor analysis showed that the factors influencing service quality in nursing homes were healthcare, diet/assistance, therapy, environment and staff. To improve objectivity of the instrument, quantitative as well as qualitative evaluation approaches were adopted. The study instrument was developed with 30 items and showed acceptable construct validity. The criterion-related validity was a Pearson correlation coefficient of .85 in 151 care facilities. The internal consistency was Cronbach's α=.95. The instrument has acceptable validity and a high degree of reliability. Staff in nursing homes can continuously improve and manage their services using the results of the evaluation instrument.

  7. Rating counselor-client behavior in online counseling: development and preliminary psychometric properties of the Counseling Progress and Depth Rating Instrument.

    Science.gov (United States)

    Bagraith, Karl; Chardon, Lydia; King, Robert John

    2010-11-01

    Although there are widely accepted and utilized models and frameworks for nondirective counseling (NDC), there is little in the way of tools or instruments designed to assist in determining whether or not a specific episode of counseling is consistent with the stated model or framework. The Counseling Progress and Depth Rating Instrument (CPDRI) was developed to evaluate counselor integrity in the use of Egan's skilled helper model in online counseling. The instrument was found to have sound internal consistency, good interrater reliability, and good face and convergent validity. The CPDRI is, therefore, proposed as a useful tool to facilitate investigation of the degree to which counselors adhere to and apply a widely used approach to NDC.

  8. Nuclear power plant control and instrumentation 1982. Proceedings of an international symposium on nuclear power plant control and instrumentation

    International Nuclear Information System (INIS)

    1983-01-01

    Ever increasing demands for nuclear power plant safety and availability imply a need for the introduction of modern measurement and control methods, together with data processing techniques based on the latest advances in electronic components, transducers and computers. Nuclear power plant control and instrumentation is therefore an extremely rapidly developing field. The present symposium, held in Munich, FR Germany, was prepared with the help of the IAEA International Working Group on Nuclear Power Plant Control and Instrumentation and organized in close co-operation with the Gesellschaft fur Reaktorsicherheit, Federal Republic of Germany. A number of developments were highlighted at the Munich symposium: - The increased use of computers can bring clear advantages and this technique is now proven as a tool for supervising and controlling plant operation. Advanced computerized systems for operator support are being developed on a large scale in many countries. The progress in this field is quite obvious, especially in disturbance analysis, safety parameter display, plant operator guidance and plant diagnostics. The new trend of introducing computers and microprocessors in protection systems makes it easy to implement 'defence-in-depth' strategies which give better assurance of correct system responses and also prevent unnecessary reactor trips, thus improving plant availability. The introduction of computerized systems for control of reactor power, reactor water level and reactor pressure as well as for reactor start-up and shut-down could improve the reliability and availability of nuclear power plants. The rapid technical development in the area of control and instrumentation makes it necessary to plan for at least one replacement of obsolete equipment in the course of the 30 years lifetime of a nuclear power plant and retrofitting of currently operating reactors with new control systems. Major design improvements and regulatory requirements also require

  9. Internal consistency and validity of an observational method for assessing disability in mobility in patients with osteoarthritis.

    NARCIS (Netherlands)

    Steultjens, M.P.M.; Dekker, J.; Baar, M.E. van; Oostendorp, R.A.B.; Bijlsma, J.W.J.

    1999-01-01

    Objective: To establish the internal consistency of validity of an observational method for assessing diasbility in mobility in patients with osteoarthritis (OA), Methods: Data were obtained from 198 patients with OA of the hip or knee. Results of the observational method were compared with results

  10. Rio de Janeiro: Instrumentation school

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    Students from Latin America were able to get hands-on experience in state-of-the-art physics instrumentation in this year's School on Instrumentation for High Energy Physics organized by the active Instrumentation Panel of ICFA (the International Committee for Future Accelerators) at the Centro Brasileiro de Pesquicas Fisicas (CBPF), Rio de Janeiro, in July

  11. ASIM - an Instrument Suite for the International Space Station

    DEFF Research Database (Denmark)

    Neubert, Torsten; Crosby, B.; Huang, T.-Y.

    2009-01-01

    ASIM (Atmosphere-Space Interactions Monitor) is an instrument suite for studies of severe thunderstorms and their effects on the atmosphere and ionosphere. The instruments are designed to observe transient luminous events (TLEs)—sprites, blue jets and elves—and terrestrial gamma-ray flashes (TGFs...

  12. GLOBALIZATION AND THE DECLINE OF THE UNITED STATES ECONOMIC INSTRUMENT OF POWER

    Science.gov (United States)

    2017-06-01

    of global trade relations. Whereas forty years ago, 90 percent of international trade consisted of mercantilist goods; today , 90 percent of... GLOBALIZATION AND THE DECLINE OF THE UNITED STATES ECONOMIC INSTRUMENT OF POWER BY MAJOR JOSH WATKINS A THESIS PRESENTED TO THE...bachelor of business administration degree from Old Dominion University in 2001. He was commissioned through Officer Training School in 2002 and his

  13. Psychometric Evaluation of a New Instrument to Evaluate School Nurses' Perceptions on Concussion Care Management.

    Science.gov (United States)

    Schneider, Kathleen H

    2017-10-01

    The rate of concussions in adolescents has risen over the last decade, resulting in cognitive and emotional problems. Neurologists recommend cognitive and physical rest during the recovery period, followed by a transitional return-to-classroom protocol. The purpose of the study was to develop and test an instrument that explores the beliefs and roles of school nurses in concussion care management. The instrument was a cross-sectional descriptive survey based on the theory of planned behavior, using Qualtrics®. The psychometric properties of the instrument were assessed through exploratory factor analysis with orthogonal rotation. The reliability of the instrument was assessed for internal consistency reliability using Cronbach's α. Kaiser-Meyer-Olkin for sample adequacy was .8; Cronbach's α strong (.851).

  14. Internal consistency and validity of an observational method for assessing disability in mobility in patients with osteoarthritis

    NARCIS (Netherlands)

    Steultjens, M. P.; Dekker, J.; van Baar, M. E.; Oostendorp, R. A.; Bijlsma, J. W.

    1999-01-01

    To establish the internal consistency and validity of an observational method for assessing disability in mobility in patients with osteoarthritis (OA). Data were obtained from 198 patients with OA of the hip or knee. Results of the observational method were compared with results of self-report

  15. To IO-3 type instrument for measuring relative deviation of mean frequency

    International Nuclear Information System (INIS)

    Albats, Ya.Eh.; Bitite, Ya.A.; Ivanov, G.M.; Karpel'tseva, L.P.; Tesnavs, Eh.R.; Shuvtsan, Ya.V.

    1979-01-01

    A description is given of the 10-3 instrument intended for automatic measurement of a relative deviation of the pulse flow mean frequency from the preset value with digital presentation of measurement results, and also for the conversion of this relative deviation into an electric coded signal and in an analogue voltage signal. The 10-3 instrument comprises a master pulse generator, two preliminary scalers, two electronic switches, two storage pulse counters, control devices, a counter digital volume setter, a rewriting device, an internal storage, a digital display, and a digital-to-analog converter. The principle of the instrument operation consists in counting the pulses of measured and reference pulse flows by two storage counters. Basic performances of the instrument are given. The main advantage of the 10-3 instrument lies in the fact that it presents the results of measuring by a digital radioisotope instrument directly in physical units of the measured parameter, and that, in turn, obviates the necessity for additional mathematical operations when data processing [ru

  16. An Attitude Scale on Individual Instrument and Individual Instrument Course: Validity-Reliability Research

    Science.gov (United States)

    Kuçukosmanoglu, Hayrettin Onur

    2015-01-01

    The main purpose of this study is to develop a scale to determine students' attitude levels on individual instruments and individual instrument courses in instrument training, which is an important dimension of music education, and to conduct a validity-reliability research of the scale that has been developed. The scale consists of 16 items. The…

  17. Gene-Environment Interplay in Internalizing Disorders: Consistent Findings across Six Environmental Risk Factors

    Science.gov (United States)

    Hicks, Brian M.; DiRago, Ana C.; Iacono, William G.; McGue, Matt

    2009-01-01

    Background Newer behavior genetic methods can better elucidate gene-environment (G-E) interplay in the development of internalizing (INT) disorders (i.e., major depression and anxiety disorders). However, no study to date has conducted a comprehensive analysis examining multiple environmental risks with the purpose of delineating how general G-E mechanisms influence the development of INT disorders. Methods The sample consisted of 1315 male and female twin pairs participating in the age 17 assessment of the Minnesota Twin Family Study. Quantitative G-E interplay models were used to examine how genetic and environmental risk for INT disorders changes as a function of environmental context. Multiple measures and informants were employed to construct composite measures of INT disorders and 6 environmental risk factors including: stressful life events, mother-child and father-child relationship problems, antisocial and prosocial peer affiliation, and academic achievement and engagement. Results Significant moderation effects were detected between each environmental risk factor and INT such that in the context of greater environmental adversity, nonshared environmental factors became more important in the etiology of INT symptoms. Conclusion Our results are consistent with the interpretation that environmental stressors have a causative effect on the emergence of INT disorders. The consistency of our results suggests a general mechanism of environmental influence on INT disorders regardless of the specific form of environmental risk. PMID:19594836

  18. The eye-complaint questionnaire in a visual display unit work environment: Internal consistency and test-retest reliability

    NARCIS (Netherlands)

    Steenstra, Ivan A.; Sluiter, Judith K.; Frings-Dresen, Monique H. W.

    2009-01-01

    The internal consistency and test-retest reliability of a 10-item eye-complaint questionnaire (ECQ) were examined within a sample of office workers. Repeated within-subjects measures were performed within a single day and over intervals of 1 and 7 d. Questionnaires were completed by 96 workers (70%

  19. THE FINANCIAL INSTRUMENTS FOR RISK MANAGEMENT ON THE INTERNATIONAL FINANCIAL MARKETS

    Directory of Open Access Journals (Sweden)

    Alina Hagiu

    2008-05-01

    Full Text Available The international financial market is extremely volatile because of the influence of anumerous objective and subjective factors. Because of these, în their fight for maximizing the profit, the creditinstitutes confronts permanently with all sort of risks.It is important to know that the risk is generated by a numerous operations and procedures. From thesecause, at least în the financial field, the risk must be considered as a complex of risks, în the sense that they canhave common causes, and producing a risk can generate a chain reaction, and producing other risks. As aconsequence, these operations and procedures can permanently generate an exposure to the risk.The risk management is the key function of the financial institution, which act on the internationalfinancial market. For doing this, it must be used some important instruments that can conduce to avoiding risksor dimensioning them.

  20. Psychometric Properties of an Instrument to Measure Mother-Infant Togetherness After Childbirth.

    Science.gov (United States)

    Lawrence, Carol L; Norris, Anne E

    2016-01-01

    The purpose of this research was to evaluate the psychometric properties of a new instrument to measure mother-infant togetherness, Mother-Infant Togetherness Survey (MITS). Stage 1 examined content validity. Stage 2 pretested the readability and understandability and further examined content validity. Stage 3 examined women's ability to accurately self-report on the Delivery Events subscale. Stages 4 and 5 examined construct validity. Good content validity was obtained at the scale/subscale level (CVI = .91-1.00). Internal consistency reliability was evaluated at the scale/subscale level (α = .62-.89). Construct validity was supported with known groups testing and factor analysis. Study findings provide support for the reliability and validity of the MITS. Future research should be done to improve the internal consistency reliability of the Postpartum Events subscale.

  1. Brazil-Portugal Transcultural Adaptation of the UWES-9: Internal Consistency, Dimensionality, and Measurement Invariance.

    Science.gov (United States)

    Sinval, Jorge; Pasian, Sonia; Queirós, Cristina; Marôco, João

    2018-01-01

    The aim of this paper is to present a revision of international versions of the Utrecht Work Engagement Scale and to describe the psychometric properties of a Portuguese version of the UWES-9 developed simultaneously for Brazil and Portugal, the validity evidence related with the internal structure, namely, Dimensionality, measurement invariance between Brazil and Portugal, and Reliability of the scores. This is the first UWES version developed simultaneously for both countries, and it is an important instrument for understanding employees' work engagement in the organizations, allowing human resources departments to better use workforces, especially when they are migrants. A total of 524 Brazilian workers and 522 Portuguese workers participated in the study. Confirmatory Factor Analysis, group comparisons, and Reliability estimates were used. The use of workers who were primarily professionals or administrative support, according to ISCO-08, reinforced the need to collect data on other professional occupations. Confirmatory factor analysis showed acceptable fit for the UWES-9 original three-factor solution, and a second-order factor structure has been proposed that presented an acceptable fit. Full-scale invariance was obtained between the Portuguese and Brazilian samples, both for the original three-factor first-order and second-order models. Data revealed that Portuguese and Brazilian workers didn't show statistically significant differences in the work engagement dimensions. This version allows for direct comparisons of means and, consequently, for performance of comparative and cross-cultural studies between these two countries.

  2. Brazil-Portugal Transcultural Adaptation of the UWES-9: Internal Consistency, Dimensionality, and Measurement Invariance

    Directory of Open Access Journals (Sweden)

    Jorge Sinval

    2018-03-01

    Full Text Available The aim of this paper is to present a revision of international versions of the Utrecht Work Engagement Scale and to describe the psychometric properties of a Portuguese version of the UWES-9 developed simultaneously for Brazil and Portugal, the validity evidence related with the internal structure, namely, Dimensionality, measurement invariance between Brazil and Portugal, and Reliability of the scores. This is the first UWES version developed simultaneously for both countries, and it is an important instrument for understanding employees' work engagement in the organizations, allowing human resources departments to better use workforces, especially when they are migrants. A total of 524 Brazilian workers and 522 Portuguese workers participated in the study. Confirmatory Factor Analysis, group comparisons, and Reliability estimates were used. The use of workers who were primarily professionals or administrative support, according to ISCO-08, reinforced the need to collect data on other professional occupations. Confirmatory factor analysis showed acceptable fit for the UWES-9 original three-factor solution, and a second-order factor structure has been proposed that presented an acceptable fit. Full-scale invariance was obtained between the Portuguese and Brazilian samples, both for the original three-factor first-order and second-order models. Data revealed that Portuguese and Brazilian workers didn't show statistically significant differences in the work engagement dimensions. This version allows for direct comparisons of means and, consequently, for performance of comparative and cross-cultural studies between these two countries.

  3. Instrumental charged-particle activation analysis of several selected elements in biological materials using the internal standard method

    International Nuclear Information System (INIS)

    Yagi, M.; Masumoto, K.

    1987-01-01

    In order to study instrumental charged-particle activation analysis using the internal standard method, simultaneous determinations of several selected elements such as Ca, Ti, V, Fe, Zn, As, Sr, Zr and Mo, in oyster tissue, brewer's yeast and mussel were carried out by using the respective (p, n) reactions and a personal computer-based gamma-ray spectrometer equipped with a micro-robot for sample changing. In the determination constant amounts of Y and La were added to the sample and comparative standard as exotic internal standards. As a result, it was demonstrated that concentrations of the above elements could be determined accurately and precisely. (author)

  4. Marketing instruments of foreign trade promotion

    Directory of Open Access Journals (Sweden)

    Bjelić Predrag

    2011-01-01

    Full Text Available Instruments of promotion as a part of marketing mix are usually associated with companies but more and more countries use this instrument in order to boost their exports. These foreign trade promotion instruments are now popular in many countries in the world since their use is not opposed to any World Trade Organization rules. Marketing instruments of trade promotions are the most important. They include National Exhibitions and National labels of origin and quality. In order to coordinate the application of these instruments countries have established national bodies for trade promotion. Many studies in the past had argued that national Agencies established to promote export did not had any real success, but recent studies indicate that they could have a significant impact on country export promotion. The result of this rise in impact of national export promotion agencies is due to international effort spearheaded by International Trade Center. The aim of this paper is to point out types and methods of marketing instruments application in trade promotion and to present the effectiveness of these instruments applications.

  5. Measuring the Quality of Service in the Financial Area of a Public University: Development and Validation of the Instrument

    Directory of Open Access Journals (Sweden)

    Víctor Manuel Alcantar Enríquez

    2014-12-01

    Full Text Available This research, consisting of a descriptive study with a non-experimental design, involved an analysis to determine the validity and reliability of an instrument composed of seventeen items aimed at assessing the quality of service in the financial area of a public university by means of four variables: tangibility, reliability, responsiveness and empathy. The methodological strategy included the design of the measuring instrument; verification of the validity of content and construct; and analysis of internal consistency by means of Cronbach’s alpha. The instrument was applied to 152 users of the service, attaining a reliability coefficient of 0.943. The results show that with respect to specific concepts, the questions were clear; nevertheless we found it necessary to relocate items and rename variables, which resulted in a valid and reliable instrument for measuring the quality of service in the context under study.

  6. Test-retest Reliability and Agreement of the Satisfaction with the Assistive Technology Services (SATS) Instrument in Two Nordic Countries

    DEFF Research Database (Denmark)

    Sund, Terje; Anttila, Heidi; Iwarsson, Susanne

    2014-01-01

    Purpose: The purpose of this study was to investigate test–retest reliability, agreement, internal consistency, and floor- and ceiling effects of the Danish and Finnish versions of the Satisfaction with the Assistive Technology Services (SATS) instrument among adult users of powered wheelchairs (...

  7. Proceedings of the international advisory committee on 'biomolecular dynamics instrument DNA' and the workshop on 'biomolecular dynamics backscattering spectrometers'

    International Nuclear Information System (INIS)

    Arai, Masatoshi; Aizawa, Kazuya; Nakajima, Kenji; Shibata, Kaoru; Takahashi, Nobuaki

    2008-08-01

    A workshop entitled 'Biomolecular Dynamics Backscattering Spectrometers' was held on February 27th - 29th, 2008 at J-PARC Center, Japan Atomic Energy Agency. This workshop was planned to be held for aiming to realize an innovative neutron backscattering instrument, namely DNA, in the MLF and thus four leading scientists in the field of neutron backscattering instruments were invited as the International Advisory Committee (IAC member: Dr. Dan Neumann (Chair); Prof. Ferenc Mezei; Dr. Hannu Mutka; Dr. Philip Tregenna-Piggott) for DNA from institutes in the United States, France and Switzerland, where backscattering instruments are in-service. It was therefore held in the form of lecture anterior and then in the form of the committee posterior. This report includes the executive summary of the IAC and materials of the presentations in the IAC and the workshop. (author)

  8. Translation, cultural adaptation and validation for Brazilian Portuguese of the Cardiff Acne Disability Index instrument.

    Science.gov (United States)

    Grando, Luciana Rosa; Horn, Roberta; Cunha, Vivian Trein; Cestari, Tania Ferreira

    2016-04-01

    The Cardiff Acne Disability Index was originally developed in English for measuring quality of life of acne patients. Considering the psychosocial impact of this disease, it is important to have instruments culturally and linguistically validated for use in Brazilian adolescents. To translate the Cardiff Acne Disability Index into Brazilian Portuguese, culturally adapt it, and verify its reliability and validity in adolescent patients with acne. In the first step, the Cardiff Acne Disability Index was translated and validated linguistically to Brazilian Portuguese in accordance with international guidelines published. In the second step, the validation of the Cardiff Acne Disability Index into Brazilian Portuguese instrument was performed, when patients aged from 12 to 20 years with acne were selected. The participants were interviewed to collect demographic data, submitted to the classification of acne by the Global Acne Grading System and invited to respond the Cardiff Acne Disability Index into Brazilian Portuguese version and DLQI (>16 years) or CDLQI (≤16 years). The internal consistency of Cardiff Acne Disability Index into Brazilian Portuguese was assessed by Cronbach's alpha coefficient and concurrent validity was measured by the Spearman correlation coefficient and Student 's t-test for paired samples. The study included 100 adolescents. The Cardiff Acne Disability Index into Brazilian Portuguese version showed good reliability and internal consistency (Cronbach's alpha = 0.73). The concurrent validity of the scale was supported by a strong and significant correlation with CDLQI / DLQI instruments (rs=0.802;pPortuguese version is a reliable, valid and valuable tool to measure the impact of acne on quality of life in adolescent patients.

  9. Self-Tuning Fully-Connected PID Neural Network System for Distributed Temperature Sensing and Control of Instrument with Multi-Modules.

    Science.gov (United States)

    Zhang, Zhen; Ma, Cheng; Zhu, Rong

    2016-10-14

    High integration of multi-functional instruments raises a critical issue in temperature control that is challenging due to its spatial-temporal complexity. This paper presents a multi-input multi-output (MIMO) self-tuning temperature sensing and control system for efficiently modulating the temperature environment within a multi-module instrument. The smart system ensures that the internal temperature of the instrument converges to a target without the need of a system model, thus making the control robust. The system consists of a fully-connected proportional-integral-derivative (PID) neural network (FCPIDNN) and an on-line self-tuning module. The experimental results show that the presented system can effectively control the internal temperature under various mission scenarios, in particular, it is able to self-reconfigure upon actuator failure. The system provides a new scheme for a complex and time-variant MIMO control system which can be widely applied for the distributed measurement and control of the environment in instruments, integration electronics, and house constructions.

  10. Self-Tuning Fully-Connected PID Neural Network System for Distributed Temperature Sensing and Control of Instrument with Multi-Modules

    Directory of Open Access Journals (Sweden)

    Zhen Zhang

    2016-10-01

    Full Text Available High integration of multi-functional instruments raises a critical issue in temperature control that is challenging due to its spatial–temporal complexity. This paper presents a multi-input multi-output (MIMO self-tuning temperature sensing and control system for efficiently modulating the temperature environment within a multi-module instrument. The smart system ensures that the internal temperature of the instrument converges to a target without the need of a system model, thus making the control robust. The system consists of a fully-connected proportional–integral–derivative (PID neural network (FCPIDNN and an on-line self-tuning module. The experimental results show that the presented system can effectively control the internal temperature under various mission scenarios, in particular, it is able to self-reconfigure upon actuator failure. The system provides a new scheme for a complex and time-variant MIMO control system which can be widely applied for the distributed measurement and control of the environment in instruments, integration electronics, and house constructions.

  11. Content comparison of occupation-based instruments in adult rheumatology and musculoskeletal rehabilitation based on the International Classification of Functioning, Disability and Health.

    Science.gov (United States)

    Stamm, Tanja A; Cieza, Alarcos; Machold, Klaus P; Smolen, Josef S; Stucki, Gerold

    2004-12-15

    To compare the content of clinical, occupation-based instruments that are used in adult rheumatology and musculoskeletal rehabilitation in occupational therapy based on the International Classification of Functioning, Disability and Health (ICF). Clinical instruments of occupational performance and occupation in adult rehabilitation and rheumatology were identified in a literature search. All items of these instruments were linked to the ICF categories according to 10 linking rules. On the basis of the linking, the content of these instruments was compared and the relationship between the capacity and performance component explored. The following 7 instruments were identified: the Canadian Occupational Performance Measure, the Assessment of Motor and Process Skills, the Sequential Occupational Dexterity Assessment, the Jebson Taylor Hand Function Test, the Moberg Picking Up Test, the Button Test, and the Functional Dexterity Test. The items of the 7 instruments were linked to 53 different ICF categories. Five items could not be linked to the ICF. The areas covered by the 7 occupation-based instruments differ importantly: The main focus of all 7 instruments is on the ICF component activities and participation. Body functions are covered by 2 instruments. Two instruments were linked to 1 single ICF category only. Clinicians and researchers who need to select an occupation-based instrument must be aware of the areas that are covered by this instrument and the potential areas that are not covered at all.

  12. Measurement of factors that negatively influence the outcome of quitting smoking among patients with COPD: psychometric analyses of the Try To Quit Smoking instrument.

    Science.gov (United States)

    Lundh, Lena; Alinaghizadeh, Hassan; Törnkvist, Lena; Gilljam, Hans; Galanti, Maria Rosaria

    2014-12-01

    To test internal consistency and factor structure of a brief instrument called Trying to Quit smoking. The most effective treatment for patients with chronic obstructive pulmonary disease is to quit smoking. Constant thoughts about quitting and repeated quit attempts can generate destructive feelings and make it more difficult to quit. Development and psychometric testing of the Trying to Quit smoking scale. The Trying to Quit smoking, an instrument designed to assess pressure-filled states of mind and corresponding pressure-relief strategies, was tested among 63 Swedish patients with chronic obstructive pulmonary disease. Among these, the psychometric properties of the instrument were analysed by Exploratory Factor Analyses. Fourteen items were included in the factor analyses, loading on three factors labelled: (1) development of pressure-filled mental states; (2) use of destructive pressure-relief strategies; and (3) ambivalent thoughts when trying to quit smoking. These three factors accounted for more than 80% of the variance, performed well on the Kaiser-Meyer-Olkin (KMO) test and had high internal consistency.

  13. The MacArthur Competence Assessment Tool-Fitness to Plead: a preliminary evaluation of a research instrument for assessing fitness to plead in England and Wales.

    Science.gov (United States)

    Akinkunmi, Akintunde A

    2002-01-01

    This study concerns the preliminary evaluation of an instrument, the MacArthur Competence Assessment Tool-Fitness to Plead (MacCAT-FP), for assessing competence to stand trial, according to the legal requirements in England and Wales. The purposes of the study were to ascertain whether the instrument can be administered practically to groups of prisoners, both those with mental illness and those without; to examine its internal consistency and interrater reliability; to determine whether it can distinguish between fit and unfit individuals, as judged by expert forensic psychiatrists; and to discover whether it is sensitive to changes over time. The instrument was administered to two groups of remanded prisoners: those transferred to psychiatric units for treatment and those without mental illness. In addition to the MacCAT-FP, scales measuring symptom severity and IQ were administered to all participants. Results suggest that the instrument is practical, with good internal consistency and interrater reliability. The correlation of scores with psychiatrists' opinions as to fitness was 0.77. Scores of unfit patients were significantly different from those of fit individuals. The instrument was able to detect significant differences in scores over time. It is suggested that once the instrument has been further validated for research purposes, it may be developed for clinical application.

  14. A method and instruments to identify the torque, the power and the efficiency of an internal combustion engine of a wheeled vehicle

    Science.gov (United States)

    Egorov, A. V.; Kozlov, K. E.; Belogusev, V. N.

    2018-01-01

    In this paper, we propose a new method and instruments to identify the torque, the power, and the efficiency of internal combustion engines in transient conditions. This method, in contrast to the commonly used non-demounting methods based on inertia and strain gauge dynamometers, allows controlling the main performance parameters of internal combustion engines in transient conditions without inaccuracy connected with the torque loss due to its transfer to the driving wheels, on which the torque is measured with existing methods. In addition, the proposed method is easy to create, and it does not use strain measurement instruments, the application of which does not allow identifying the variable values of the measured parameters with high measurement rate; and therefore the use of them leads to the impossibility of taking into account the actual parameters when engineering the wheeled vehicles. Thus the use of this method can greatly improve the measurement accuracy and reduce costs and laboriousness during testing of internal combustion engines. The results of experiments showed the applicability of the proposed method for identification of the internal combustion engines performance parameters. In this paper, it was determined the most preferred transmission ratio when using the proposed method.

  15. Validity and Reliability of the Clinical Competency Evaluation Instrument for Use among Physiotherapy Students: Pilot study.

    Science.gov (United States)

    Muhamad, Zailani; Ramli, Ayiesah; Amat, Salleh

    2015-05-01

    The aim of this study was to determine the content validity, internal consistency, test-retest reliability and inter-rater reliability of the Clinical Competency Evaluation Instrument (CCEVI) in assessing the clinical performance of physiotherapy students. This study was carried out between June and September 2013 at University Kebangsaan Malaysia (UKM), Kuala Lumpur, Malaysia. A panel of 10 experts were identified to establish content validity by evaluating and rating each of the items used in the CCEVI with regards to their relevance in measuring students' clinical competency. A total of 50 UKM undergraduate physiotherapy students were assessed throughout their clinical placement to determine the construct validity of these items. The instrument's reliability was determined through a cross-sectional study involving a clinical performance assessment of 14 final-year undergraduate physiotherapy students. The content validity index of the entire CCEVI was 0.91, while the proportion of agreement on the content validity indices ranged from 0.83-1.00. The CCEVI construct validity was established with factor loading of ≥0.6, while internal consistency (Cronbach's alpha) overall was 0.97. Test-retest reliability of the CCEVI was confirmed with a Pearson's correlation range of 0.91-0.97 and an intraclass coefficient correlation range of 0.95-0.98. Inter-rater reliability of the CCEVI domains ranged from 0.59 to 0.97 on initial and subsequent assessments. This pilot study confirmed the content validity of the CCEVI. It showed high internal consistency, thereby providing evidence that the CCEVI has moderate to excellent inter-rater reliability. However, additional refinement in the wording of the CCEVI items, particularly in the domains of safety and documentation, is recommended to further improve the validity and reliability of the instrument.

  16. Nuclear measurements, techniques and instrumentation, industrial applications, plasma physics and nuclear fusion 1986-1996. International Atomic Energy Agency publications

    International Nuclear Information System (INIS)

    1997-03-01

    This catalogue lists all sales publications of the International Atomic Energy Agency dealing with Nuclear Measurements, Techniques, and Instrumentation, Industrial Applications, Plasma Physics and Nuclear Fusion, issued during the period 1986-1996. Most publications are in English. Proceedings of conferences, symposia and panels of experts may contain some papers in languages other than English (French, Russian or Spanish), but all of these papers have abstracts in English. Contents cover the three main areas of (i) Nuclear Measurements, Techniques and Instrumentation (Physics, Dosimetry Techniques, Nuclear Analytical Techniques, Research Reactor and Particle Accelerator Applications, and Nuclear Data), (ii) Industrial Applications (Radiation Processing, Radiometry, and Tracers), and (iii) Plasma Physics and Controlled Thermonuclear Fusion

  17. Teaching Behaviour and Well-Being in Students: Development and Concurrent Validity of an Instrument to Measure Student-Reported Teaching Behaviour

    Directory of Open Access Journals (Sweden)

    Patrick Pössel

    2013-11-01

    Full Text Available Teaching behavior has important implications for students’ emotional well-being. Multiple models suggest students’ perceptions of teaching behaviors are more critical than other measures for predicting well-being, yet student-report instruments that measure concrete and specific teaching behavior are limited. The purpose of the present studies is to develop an instrument to assess students’ perceptions of concrete and specific teaching behavior and to test which teaching behavior is associated students’ well-being. Construct validity and internal consistency for the 37-item Teaching Behavior Questionnaire (TBQ-S, composed of instructional, negative teaching, socioemotional, and organizational behavior were examined using data from two independent samples (Study 1: n = 703; Study 2: n = 822. The factor structure was stable across both samples and internal consistencies ranged from .77 to .97. Results indicated student-ratings of teaching behavior were associated with positive and negative affect in students.

  18. International standards for monoclonal antibodies to support pre- and post-marketing product consistency: Evaluation of a candidate international standard for the bioactivities of rituximab.

    Science.gov (United States)

    Prior, Sandra; Hufton, Simon E; Fox, Bernard; Dougall, Thomas; Rigsby, Peter; Bristow, Adrian

    2018-01-01

    The intrinsic complexity and heterogeneity of therapeutic monoclonal antibodies is built into the biosimilarity paradigm where critical quality attributes are controlled in exhaustive comparability studies with the reference medicinal product. The long-term success of biosimilars will depend on reassuring healthcare professionals and patients of consistent product quality, safety and efficacy. With this aim, the World Health Organization has endorsed the need for public bioactivity standards for therapeutic monoclonal antibodies in support of current controls. We have developed a candidate international potency standard for rituximab that was evaluated in a multi-center collaborative study using participants' own qualified Fc-effector function and cell-based binding bioassays. Dose-response curve model parameters were shown to reflect similar behavior amongst rituximab preparations, albeit with some differences in potency. In the absence of a common reference standard, potency estimates were in poor agreement amongst laboratories, but the use of the candidate preparation significantly reduced this variability. Our results suggest that the candidate rituximab standard can support bioassay performance and improve data harmonization, which when implemented will promote consistency of rituximab products over their life-cycles. This data provides the first scientific evidence that a classical standardization exercise allowing traceability of bioassay data to an international standard is also applicable to rituximab. However, we submit that this new type of international standard needs to be used appropriately and its role not to be mistaken with that of the reference medicinal product.

  19. Towards consistent and reliable Dutch and international energy statistics for the chemical industry

    International Nuclear Information System (INIS)

    Neelis, M.L.; Pouwelse, J.W.

    2008-01-01

    Consistent and reliable energy statistics are of vital importance for proper monitoring of energy-efficiency policies. In recent studies, irregularities have been reported in the Dutch energy statistics for the chemical industry. We studied in depth the company data that form the basis of the energy statistics in the Netherlands between 1995 and 2004 to find causes for these irregularities. We discovered that chemical products have occasionally been included, resulting in statistics with an inconsistent system boundary. Lack of guidance in the survey for the complex energy conversions in the chemical industry in the survey also resulted in large fluctuations for certain energy commodities. The findings of our analysis have been the basis for a new survey that has been used since 2007. We demonstrate that the annual questionnaire used for the international energy statistics can result in comparable problems as observed in the Netherlands. We suggest to include chemical residual gas as energy commodity in the questionnaire and to include the energy conversions in the chemical industry in the international energy statistics. In addition, we think the questionnaire should be explicit about the treatment of basic chemical products produced at refineries and in the petrochemical industry to avoid system boundary problems

  20. Psychometric testing of an instrument to measure the experience of home.

    Science.gov (United States)

    Molony, Sheila L; McDonald, Deborah Dillon; Palmisano-Mills, Christine

    2007-10-01

    Research related to quality of life in long-term care has been hampered by a paucity of measurement tools sensitive to environmental interventions. The primary aim of this study was to test the psychometric properties of a new instrument, the Experience of Home (EOH) Scale, designed to measure the strength of the experience of meaningful person-environment transaction. The instrument was administered to 200 older adults in diverse dwelling types. Principal components analysis provided support for construct validity, eliciting a three-factor solution accounting for 63.18% of variance in scores. Internal consistency reliability was supported with Cronbach's alpha of .96 for the entire scale. The EOH Scale is a unique research tool to evaluate interventions to improve quality of living in residential environments.

  1. Development of a patient-reported outcome instrument for patients with lumbar radicular pain

    OpenAIRE

    Ibsen, Charlotte; Schiøttz-Christensen, Berit; Handberg, Charlotte; Nielsen, Claus Vinther; Hørder, Mogens; Maribo, Thomas

    2017-01-01

    Background Low back pain (LBP) is the leading cause to years lived with disability. 10–20% of patients with LBP experience radicular pain (lumbar radiculopathy). Patient-reported outcomes (PROs) play an important role in advancing patient-centered health care. Although patient involvement is essential to develop valid patient-centred PRO instruments patients are not always involved. The International Classification of Functioning, Disability and Health (ICF) are proposed to facilitate consist...

  2. The N2N instrument to evaluate healthy work environments: an Italian validation.

    Science.gov (United States)

    Palese, Alvisa; Dante, Angelo; Tonzar, Laura; Balboni, Bernardo

    2014-02-01

    The aims of the study were to (a) validate N2N Healthy Work Environment tool, (b) assess the healthiness of work environments as perceived by nurses themselves and (c) identify the factors associated with Italian nurses' perception of work environment healthiness. The linguistic and cultural adaptation of USA-N2N Healthy Work Environments was achieved through a process of forward/backward translation. Content validity was assessed by three expert nurses. The stability of the instrument was checked with a test/retest evaluation. The instrument psychometric properties, the confirmatory factor analysis as well the healthiness of the work environment and its determinant factors were evaluated with a sample of 294 nurses. The content and face validity of the N2N Healthy Work Environment instrument was confirmed. The instrument demonstrated good internal consistency (α of 0.82), excellent stability values (ρ > 0.70) and high levels of acceptability (response rate: 96.4 %). The confirmatory factor analysis has corroborated the existence of two factors as documented in the original instrument (Mays et al. in J Nurs Manag 19:18-26, 2011). Eighty-seven (29.6 %) nurses perceived the work environment where they work as "healthy". Working under a functional model of care delivery (χ(2) 24.856, p 0.000) and being responsible for one project or more (χ(2) 5.256, p 0.021) were associated with healthy environments. The instrument--valid and reliable, short in the number of items, easy to understand and based on international standards--allows a systematic assessment of the healthiness of the environment and might provide not only the opportunity to evaluate the effects of new organizational models and interventions, but also the possibility to activate a process of self-analysis and a process of ongoing review. The instrument can be used to systematically check the healthiness of Italian working environments, allowing for organizational diagnosis, targeted interventions and

  3. Proceedings of the 2nd international advisory committee on biomolecular dynamics instrument DNA in MLF at J-PARC

    International Nuclear Information System (INIS)

    Arai, Masatoshi; Aizawa, Kazuya; Nakajima, Kenji; Shibata, Kaoru; Takahashi, Nobuaki

    2009-07-01

    The 2nd International Advisory Committee on the 'Biomolecular Dynamics Backscattering Spectrometer DNA' was held on November 12th - 13th, 2008 at J-PARC Center, Japan Atomic Energy Agency. This IAC has been organized for aiming to realize an innovative neutron backscattering instrument in the Materials and Life Science Experimental Facility (MLF) at the J-PARC and therefore four leading scientists in the field of neutron backscattering instruments has been selected as the member (Dr. Dan Neumann (Chair); Prof. Ferenc Mezei; Dr. Hannu Mutka; Dr. Philip Tregenna-Piggott), and the 1st IAC had been held on February 27th - 29th, 2008. This report includes the executive summary and materials of the presentations in the 2nd IAC. (author)

  4. Instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-15

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  5. Instrumental analysis

    International Nuclear Information System (INIS)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-01

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  6. Radiation protection instruments based on tissue equivalent proportional counters: Part II of an international intercomparison

    International Nuclear Information System (INIS)

    Alberts, W.G.; Dietz, E.; Guldbakke, S.; Kluge, H.; Schumacher, H.

    1988-04-01

    This report describes the irradiation conditions and procedures of Part II of an international intercomparison of tissue-equivalent proportional counters used for radiation protection measurements. The irradiations took place in monoenergetic reference neutron fields produced by the research reactor and accelerator facilities of the PTB Braunschweig in the range from thermal neutrons to 14.8 MeV. In addition measurements were performed in 60 Co and D 2 O-moderated 252 Cf radiation fields. Prototype instruments from 7 European groups were investigated. The results of the measurements are summarized and compared with the reference data of the irradiations. (orig.) [de

  7. An Instrument to Measure Dental Students' Communication Skills With Patients in Six Specific Circumstances: An Exploratory Factor Analysis.

    Science.gov (United States)

    Aalboe, Joanna A; Schumacher, Mitzi M

    2016-01-01

    The aim of this study was to explore the internal structure of an instrument assessing dental students' confidence in their ability to communicate with patients in six specific circumstances (anxious, in pain, etc.) using exploratory factor analysis. In a Communication in the Dental Health Care Setting course at a U.S. dental school, second-year dental students in two years (2013 and 2014) responded to the six items on a survey instrument. Of the total 123 students, 122 fully completed the instrument, for a response rate of 99%. Analysis of the results identified a unidimensional scale with regards to patient-specific communication self-efficacy and explained 74% of the total variance. The scale had good internal consistency reflected by high Cronbach's alpha (α=0.929, 95% CI [0.907, 0.947]). These findings suggest the instrument may be a useful tool in assessing the development of patient communication skills in second-year dental students following a course in communication. Further exploration utilizing confirmatory analysis, determining predictive validity, and assessing convergent and discriminant evidence is warranted.

  8. A proposed grading system for standardizing tumor consistency of intracranial meningiomas.

    Science.gov (United States)

    Zada, Gabriel; Yashar, Parham; Robison, Aaron; Winer, Jesse; Khalessi, Alexander; Mack, William J; Giannotta, Steven L

    2013-12-01

    Tumor consistency plays an important and underrecognized role in the surgeon's ability to resect meningiomas, especially with evolving trends toward minimally invasive and keyhole surgical approaches. Aside from descriptors such as "hard" or "soft," no objective criteria exist for grading, studying, and conveying the consistency of meningiomas. The authors designed a practical 5-point scale for intraoperative grading of meningiomas based on the surgeon's ability to internally debulk the tumor and on the subsequent resistance to folding of the tumor capsule. Tumor consistency grades and features are as follows: 1) extremely soft tumor, internal debulking with suction only; 2) soft tumor, internal debulking mostly with suction, and remaining fibrous strands resected with easily folded capsule; 3) average consistency, tumor cannot be freely suctioned and requires mechanical debulking, and the capsule then folds with relative ease; 4) firm tumor, high degree of mechanical debulking required, and capsule remains difficult to fold; and 5) extremely firm, calcified tumor, approaches density of bone, and capsule does not fold. Additional grading categories included tumor heterogeneity (with minimum and maximum consistency scores) and a 3-point vascularity score. This grading system was prospectively assessed in 50 consecutive patients undergoing craniotomy for meningioma resection by 2 surgeons in an independent fashion. Grading scores were subjected to a linear weighted kappa analysis for interuser reliability. Fifty patients (100 scores) were included in the analysis. The mean maximal tumor diameter was 4.3 cm. The distribution of overall tumor consistency scores was as follows: Grade 1, 4%; Grade 2, 9%; Grade 3, 43%; Grade 4, 44%; and Grade 5, 0%. Regions of Grade 5 consistency were reported only focally in 14% of heterogeneous tumors. Tumors were designated as homogeneous in 68% and heterogeneous in 32% of grades. The kappa analysis score for overall tumor consistency

  9. International migration to and from the United Kingdom, 1975-1999: consistency, change and implications for the labour market.

    Science.gov (United States)

    Dobson, J; McLaughlan, G

    2001-01-01

    This article presents some findings of a recent study carried out for the Home Office by the Migration Research Unit (MRU) in the Department of Geography at UCL. The study was concerned with patterns and trends in international migration to and from the United Kingdom since 1975, with a particular focus on those in employment, and drew on many sources. The statistics analysed here derive from the International Passenger Survey, including hitherto unpublished tables provided by the Office for National Statistics on migration of the employed by citizenship. They indicate remarkable consistency in some aspects of migration flows and major change in others.

  10. Measuring Environmental Factors: Unique and Overlapping International Classification of Functioning, Disability and Health Coverage of 5 Instruments.

    Science.gov (United States)

    Heinemann, Allen W; Miskovic, Ana; Semik, Patrick; Wong, Alex; Dashner, Jessica; Baum, Carolyn; Magasi, Susan; Hammel, Joy; Tulsky, David S; Garcia, Sofia F; Jerousek, Sara; Lai, Jin-Shei; Carlozzi, Noelle E; Gray, David B

    2016-12-01

    To describe the unique and overlapping content of the newly developed Environmental Factors Item Banks (EFIB) and 7 legacy environmental factor instruments, and to evaluate the EFIB's construct validity by examining associations with legacy instruments. Cross-sectional, observational cohort. Community. A sample of community-dwelling adults with stroke, spinal cord injury, and traumatic brain injury (N=568). None. EFIB covering domains of the built and natural environment; systems, services, and policies; social environment; and access to information and technology; the Craig Hospital Inventory of Environmental Factors (CHIEF) short form; the Facilitators and Barriers Survey/Mobility (FABS/M) short form; the Home and Community Environment Instrument (HACE); the Measure of the Quality of the Environment (MQE) short form; and 3 of the Patient Reported Outcomes Measurement Information System's (PROMIS) Quality of Social Support measures. The EFIB and legacy instruments assess most of the International Classification of Functioning, Disability and Health (ICF) environmental factors chapters, including chapter 1 (products and technology; 75 items corresponding to 11 codes), chapter 2 (natural environment and human-made changes; 31 items corresponding to 7 codes), chapter 3 (support and relationships; 74 items corresponding to 7 codes), chapter 4 (attitudes; 83 items corresponding to 8 codes), and chapter 5 (services, systems, and policies; 72 items corresponding to 16 codes). Construct validity is provided by moderate correlations between EFIB measures and the CHIEF, MQE barriers, HACE technology mobility, FABS/M community built features, and PROMIS item banks and by small correlations with other legacy instruments. Only 5 of the 66 legacy instrument correlation coefficients are moderate, suggesting they measure unique aspects of the environment, whereas all intra-EFIB correlations were at least moderate. The EFIB measures provide a brief and focused assessment of ICF

  11. Design, calibration and error analysis of instrumentation for heat transfer measurements in internal combustion engines

    Science.gov (United States)

    Ferguson, C. R.; Tree, D. R.; Dewitt, D. P.; Wahiduzzaman, S. A. H.

    1987-01-01

    The paper reports the methodology and uncertainty analyses of instrumentation for heat transfer measurements in internal combustion engines. Results are presented for determining the local wall heat flux in an internal combustion engine (using a surface thermocouple-type heat flux gage) and the apparent flame-temperature and soot volume fraction path length product in a diesel engine (using two-color pyrometry). It is shown that a surface thermocouple heat transfer gage suitably constructed and calibrated will have an accuracy of 5 to 10 percent. It is also shown that, when applying two-color pyrometry to measure the apparent flame temperature and soot volume fraction-path length, it is important to choose at least one of the two wavelengths to lie in the range of 1.3 to 2.3 micrometers. Carefully calibrated two-color pyrometer can ensure that random errors in the apparent flame temperature and in the soot volume fraction path length will remain small (within about 1 percent and 10-percent, respectively).

  12. Development and evaluation of the Korean Health Literacy Instrument.

    Science.gov (United States)

    Kang, Soo Jin; Lee, Tae Wha; Paasche-Orlow, Michael K; Kim, Gwang Suk; Won, Hee Kwan

    2014-01-01

    The purpose of this study is to develop and validate the Korean Health Literacy Instrument, which measures the capacity to understand and use health-related information and make informed health decisions in Korean adults. In Phase 1, 33 initial items were generated to measure functional, interactive, and critical health literacy with prose, document, and numeracy tasks. These items included content from health promotion, disease management, and health navigation contexts. Content validity assessment was conducted by an expert panel, and 11 items were excluded. In Phase 2, the 22 remaining items were administered to a convenience sample of 292 adults from community and clinical settings. Exploratory factor and item difficulty and discrimination analyses were conducted and four items with low discrimination were deleted. In Phase 3, the remaining 18 items were administered to a convenience sample of 315 adults 40-64 years of age from community and clinical settings. A confirmatory factor analysis was performed to test the construct validity of the instrument. The Korean Health Literacy Instrument has a range of 0 to 18. The mean score in our validation study was 11.98. The instrument exhibited an internal consistency reliability coefficient of 0.82, and a test-retest reliability of 0.89. The instrument is suitable for screening individuals who have limited health literacy skills. Future studies are needed to further define the psychometric properties and predictive validity of the Korean Health Literacy Instrument.

  13. The role of interactive control systems in obtaining internal consistency in the management control system package

    DEFF Research Database (Denmark)

    Toldbod, Thomas; Israelsen, Poul

    2014-01-01

    Companies rely on multiple Management Control Systems to obtain their short and long term objectives. When applying a multifaceted perspective on Management Control System the concept of internal consistency has been found to be important in obtaining goal congruency in the company. However, to d...... management is aware of this shortcoming they use the cybernetic controls more interactively to overcome this shortcoming, whereby the cybernetic controls are also used as a learning platform and not just for performance control....

  14. The Multidimensional Loss Scale: validating a cross-cultural instrument for measuring loss.

    Science.gov (United States)

    Vromans, Lyn; Schweitzer, Robert D; Brough, Mark

    2012-04-01

    The Multidimensional Loss Scale (MLS) represents the first instrument designed specifically to index Experience of Loss Events and Loss Distress across multiple domains (cultural, social, material, and intrapersonal) relevant to refugee settlement. Recently settled Burmese adult refugees (N = 70) completed a questionnaire battery, including MLS items. Analyses explored MLS internal consistency, convergent and divergent validity, and factor structure. Cronbach alphas indicated satisfactory internal consistency for Experience of Loss Events (0.85) and Loss Distress (0.92), reflecting a unitary construct of multidimensional loss. Loss Distress did not correlate with depression or anxiety symptoms and correlated moderately with interpersonal grief and trauma symptoms, supporting divergent and convergent validity. Factor analysis provided preliminary support for a five-factor model: Loss of Symbolic Self, Loss of Interdependence, Loss of Home, Interpersonal Loss, and Loss of Intrapersonal Integrity. Received well by participants, the new scale shows promise for application in future research and practice.

  15. Reliability, factor analysis and internal consistency calculation of the Insomnia Severity Index (ISI) in French and in English among Lebanese adolescents.

    Science.gov (United States)

    Chahoud, M; Chahine, R; Salameh, P; Sauleau, E A

    2017-06-01

    Our goal is to validate and to verify the reliability of the French and English versions of the Insomnia Severity Index (ISI) in Lebanese adolescents. A cross-sectional study was implemented. 104 Lebanese students aged between 14 and 19 years participated in the study. The English version of the questionnaire was distributed to English-speaking students and the French version was administered to French-speaking students. A scale (1 to 7 with 1 = very well understood and 7 = not at all) was used to identify the level of the students' understanding of each instruction, question and answer of the ISI. The scale's structural validity was assessed. The factor structure of ISI was evaluated by principal component analysis. The internal consistency of this scale was evaluated by Cronbach's alpha. To assess test-retest reliability the intraclass correlation coefficient (ICC) was used. The principal component analysis confirmed the presence of a two-component factor structure in the English version and a three-component factor structure in the French version with eigenvalues > 1. The English version of the ISI had an excellent internal consistency (α = 0.90), while the French version had a good internal consistency (α = 0.70). The ICC presented an excellent agreement in the French version (ICC = 0.914, CI = 0.856-0.949) and a good agreement in the English one (ICC = 0.762, CI = 0.481-890). The Bland-Altman plots of the two versions of the ISI showed that the responses over two weeks' were comparable and very few outliers were detected. The results of our analyses reveal that both English and French versions of the ISI scale have good internal consistency and are reproducible and reliable. Therefore, it can be used to assess the prevalence of insomnia in Lebanese adolescents.

  16. Psychometric evaluation of the Environmental Reality Shock-Related Issues and Concerns instrument for newly graduated nurses.

    Science.gov (United States)

    Kim, Eun-Young; Yeo, Jung Hee; Park, Hyunjeong; Sin, Kyung Mi; Jones, Cheryl B

    2018-02-01

    Reality shock is a critical representation of the gap between nursing education and clinical practice and it is important to explore the level of reality shock among nurses. However, there is no relevant instrument to assess the level of reality shock in South Korea. The purpose of this is to determine the validity and reliability of the Korean version of the Environmental Reality Shock-Related Issues and Concerns instrument. A cross-sectional study design was used in this study. The data collection was conducted in selected 15 hospitals in South Korea. A convenience sample of 216 newly graduated nurses participated in the study. The Korean version of the Environmental Reality Shock-Related Issues and Concerns instrument was developed through the forward-backward translation technique, and revision based on feedback from expert groups. The internal consistency reliability was assessed using Cronbach's alpha, and the construct validity was determined via exploratory and confirmatory factor analysis. The Korean version of the Environmental Reality Shock-Related Issues and Concerns has reliable internal consistency (Cronbach's alpha=0.91). Exploratory factor analysis revealed five factors including job, relationships, expectations, private life, and performance, which explained 61.92% of variance. The factor loadings ranged from 0.451 to 0.832. The five-factor structure was validated by confirmatory factor analysis (RMR0.9). It was concluded that the Korean version of the Environmental Reality Shock-Related Issues and Concerns instrument has satisfactory construct validity and reliability to measure the reality shock of newly graduated nurses in South Korea. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Validity evidence of non-technical skills assessment instruments in simulated anaesthesia crisis management.

    Science.gov (United States)

    Jirativanont, T; Raksamani, K; Aroonpruksakul, N; Apidechakul, P; Suraseranivongse, S

    2017-07-01

    We sought to evaluate the validity of two non-technical skills evaluation instruments, the Anaesthetists' Non-Technical Skills (ANTS) behavioural marker system and the Ottawa Global Rating Scale (GRS), to apply them to anaesthesia training. The content validity, response process, internal structure, relations with other variables and consequences were described for validity evidence. Simulated crisis management sessions were initiated during which two trained raters evaluated the performance of postgraduate first-, second- and third-year (PGY-1, PGY-2 and PGY-3) anaesthesia residents. The study included 70 participants, composed of 24 PGY-1, 24 PGY-2 and 22 PGY-3 residents. Both instruments differentiated the non-technical skills of PGY-1 from PGY-3 residents ( P skills were 0.86, 0.83, 0.84, 0.87, 0.80 and 0.86, respectively. The Cronbach's alpha for internal consistency of the ANTS instrument was 0.93, and was 0.96 for the Ottawa GRS. There was a high correlation between the ANTS and Ottawa GRS. The raters reported the ease of use of the Ottawa GRS compared to the ANTS. We found sufficient evidence of validity in the ANTS instrument and the Ottawa GRS for the evaluation of non-technical skills in a simulated anaesthesia setting, but the Ottawa GRS was more practical and had higher reliability.

  18. Planck 2013 results. XXXI. Consistency of the Planck data

    DEFF Research Database (Denmark)

    Ade, P. A. R.; Arnaud, M.; Ashdown, M.

    2014-01-01

    The Planck design and scanning strategy provide many levels of redundancy that can be exploited to provide tests of internal consistency. One of the most important is the comparison of the 70 GHz (amplifier) and 100 GHz (bolometer) channels. Based on dierent instrument technologies, with feeds...... in the HFI channels would result in shifts in the posterior distributions of parameters of less than 0.3σ except for As, the amplitude of the primordial curvature perturbations at 0.05 Mpc-1, which changes by about 1.We extend these comparisons to include the sky maps from the complete nine-year mission...... located dierently in the focal plane, analysed independently by dierent teams using dierent software, and near∫ the minimum of diuse foreground emission, these channels are in eect two dierent experiments. The 143 GHz channel has the lowest noise level on Planck, and is near the minimum of unresolved...

  19. ICFA Instrumentation Bulletin, Volume 14, Spring 1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-07-01

    The publication of the ICFA Instrumentation Bulletin is an activity of the Panel on Future Innovation and Development of ICFA (International Committee for Future Accelerators). The Bulletin reports on research and progress in the field of instrumentation with emphasis on application in the field of high-energy physics. It encourages issues of generic instrumentation.

  20. An Instrument to Assess Adults' Orientations toward Control versus Autonomy with Children: Reflections on Intrinsic Motivation and Perceived Competence.

    Science.gov (United States)

    Deci, Edward L.; And Others

    1981-01-01

    This article describes the development and validation of an instrument to assess adults' orientations toward control versus autonomy in their interactions with children. The responses from 68 teachers had a good range and were internally consistent and temporally stable. Further, the measure was shown to be externally valid. (Author/BW)

  1. International Corporate Debt Market

    OpenAIRE

    Manuela Geranio; Issam Hallak

    2012-01-01

    Research on international debt markets has chiefly investigated sovereign debt markets. We suggest a review of the different types of borrowers and the differences in the instruments. In particular we show that syndicated loans are an essential tool of international debt markets to monitor international markets borrowers. We also show by looking at the details of these instruments the mechanisms behind such tools.

  2. Internal consistency and construct validity of the Quality of Life in Alzheimer's Disease (QoL-AD) proxy – a secondary data analysis

    Science.gov (United States)

    Hylla, Jonas; Schwab, Christian G G; Isfort, Michael; Halek, Margareta; Dichter, Martin N

    2016-07-01

    Background: The maintenance and promotion of Quality of Life (QoL) of people with dementia is a major outcome in intervention studies and health care. The Quality of Life Alzheimer's Disease (QoL-AD) is an internationally recommended QoL measurement also available in German language. Until now, only a few results on the psychometric properties of the German QoL-AD were available. Objective: Evaluation of internal consistency and construct validity of the QoL-AD proxy. Method: A principal component analysis (secondary data analysis) of the 13 QoL-AD items was carried out based on the total sample of 234 people with dementia from nine nursing homes in Germany. Subsequently, the internal consistency of the identified factors was examined using Cronbach's alpha. Results: Two factors physical and mental health and social network were determined. Both factors explain 53 % of the total variance. The stability of both factors was validated in two sensitivity analyses. The internal consistency is good for both factors with a Cronbach's alpha of 0.88 (physical and mental health) and 0.75 (social network). Conclusion: The QoL-AD proxy allows the assessment of two relevant health-related QoL domains of people with dementia. However, in future studies especially the inter-rater reliability of the QoL-AD proxy has to be examined.

  3. Validation of an instrument to measure older adults' expectations regarding movement (ERM.

    Directory of Open Access Journals (Sweden)

    Nabila Dahodwala

    Full Text Available BACKGROUND: Many individuals with Parkinson's disease are not diagnosed and treated. Attitudes about aging and related help-seeking may affect the timely diagnosis of Parkinson's disease. Our objectives were to develop measures of older adults' expectations regarding movement with aging, specifically related to parkinsonism, and their beliefs about seeking healthcare for the diagnosis and treatment of parkinsonism. METHODS: We established content and face validity from interviews with experts, review of the literature, and pre-testing with key informants. Two 9-item instruments resulted: Expectations Regarding Movement (ERM and Healthcare Seeking Beliefs for parkinsonism (HSB. These instruments were administered to 210 older adults at senior centers to investigate internal consistency and construct validity. RESULTS: 192 (91% of the older adults completed more than 90% of the survey. The mean age was 76; 17 (9% reported parkinsonism. Both scales demonstrated good internal consistency (α = 0.90. Factor analysis supported construct validity of the ERM and HSB scores. Older age, lower education, worse self-reported health and African American race each were associated with lower ERM scores, but not HSB scores. CONCLUSION: The ERM, a brief measure of expectations regarding movement with aging, shows reliability and validity. This scale may be useful in identifying older adults at increased risk for under-identification of Parkinson's disease. Further work is needed to measure healthcare seeking for parkinsonism.

  4. Innovative instrumentation

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    At this year's particle physics conference at Brighton, a parallel session was given over to instrumentation and detector development. While this work is vital to the health of research and its continued progress, its share of prime international conference time is limited. Instrumentation can be innovative three times — first when a new idea is outlined, secondly when it is shown to be feasible, and finally when it becomes productive in a real experiment, amassing useful data rather than operational experience. Hyams' examples showed that it can take a long time for a new idea to filter through these successive stages, if it ever makes it at all

  5. Innovative instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1983-11-15

    At this year's particle physics conference at Brighton, a parallel session was given over to instrumentation and detector development. While this work is vital to the health of research and its continued progress, its share of prime international conference time is limited. Instrumentation can be innovative three times — first when a new idea is outlined, secondly when it is shown to be feasible, and finally when it becomes productive in a real experiment, amassing useful data rather than operational experience. Hyams' examples showed that it can take a long time for a new idea to filter through these successive stages, if it ever makes it at all.

  6. Evaluating the factor structure, item analyses, and internal consistency of hospital anxiety and depression scale in Iranian infertile patients

    Directory of Open Access Journals (Sweden)

    Payam Amini

    2017-09-01

    Full Text Available Background: The hospital anxiety and depression scale (HADS is a common screening tool designed to measure the level of anxiety and depression in different factor structures and has been extensively used in non-psychiatric populations and individuals experiencing fertility problems. Objective: The aims of this study were to evaluate the factor structure, item analyses, and internal consistency of HADS in Iranian infertile patients. Materials and Methods: This cross-sectional study included 651 infertile patients (248 men and 403 women referred to a referral infertility Center in Tehran, Iran between January 2014 and January 2015. Confirmatory factor analysis was used to determine the underlying factor structure of the HADS among one, two, and threefactor models. Several goodness of fit indices were utilized such as comparative, normed and goodness of fit indices, Akaike information criterion, and the root mean squared error of approximation. In addition to HADS, the Satisfaction with Life Scale questionnaires as well as demographic and clinical information were administered to all patients. Results: The goodness of fit indices through CFAs exposed that three and onefactor model provided the best and worst fit to the total, male and female datasets compared to the other factor structure models for the infertile patients. The Cronbach’s alpha for anxiety and depression subscales were 0.866 and 0.753 respectively. The HADS subscales significantly correlated with SWLS, indicating an acceptable convergent validity. Conclusion: The HADS was found to be a three-factor structure screening instrument in the field of infertility.

  7. Maintenance of scientific instruments

    International Nuclear Information System (INIS)

    Lucero, E.

    1986-01-01

    During the last years Colombia has increased the use of nuclear techniques, instruments and equipment in ambitious health programs, as well as in research centers, industry and education; this has resulted in numerous maintenance problems. As an alternative solution IAN has established a Central Maintenance Laboratory for nuclear instruments within an International Atomic Energy Agency program for eight Latin American and nine Asian Countries. Established strategies and some results are detailed in this writing

  8. The DUNDRUM Quartet: validation of structured professional judgement instruments DUNDRUM-3 assessment of programme completion and DUNDRUM-4 assessment of recovery in forensic mental health services

    Directory of Open Access Journals (Sweden)

    McDonnell Kim

    2011-07-01

    Full Text Available Abstract Background Moving a forensic mental health patient from one level of therapeutic security to a lower level or to the community is influenced by more than risk assessment and risk management. We set out to construct and validate structured professional judgement instruments for consistency and transparency in decision making Methods Two instruments were developed, the seven-item DUNDRUM-3 programme completion instrument and the six item DUNDRUM-4 recovery instrument. These were assessed for all 95 forensic patients at Ireland's only forensic mental health hospital. Results The two instruments had good internal consistency (Cronbach's alpha 0.911 and 0.887. Scores distinguished those allowed no leave or accompanied leave from those with unaccompanied leave (ANOVA F = 38.1 and 50.3 respectively, p Conclusions The DUNDRUM-3 programme completion items distinguished significantly between levels of therapeutic security while the DUNDRUM-4 recovery items consistently distinguished those given unaccompanied leave outside the hospital and those in the lowest levels of therapeutic security. This data forms the basis for a prospective study of outcomes now underway.

  9. Evaluating the Relational Coordination instrument

    DEFF Research Database (Denmark)

    Edwards, Kasper; Lundstrøm, Sanne Lykke

    2014-01-01

    consistency, interrater agreement and reliability, structural validity, content validity. However as relational coordination is being used as a diagnostics tool it is important to examine further if the instrument can measure changes. Indeed we need to know how precise and sensitive the instrument is when....... We distinguish between statistical and clinical significance. Statistical significance is calculated using T-test. Clinical significance is the minimal amount of change in relational coordination score that is not considered noise. Sensitivity of the instrument i.e. the ability of the instrument...

  10. 26 CFR 1.1275-7 - Inflation-indexed debt instruments.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 11 2010-04-01 2010-04-01 true Inflation-indexed debt instruments. 1.1275-7... Inflation-indexed debt instruments. (a) Overview. This section provides rules for the Federal income tax treatment of an inflation-indexed debt instrument. If a debt instrument is an inflation-indexed debt...

  11. Psychometric properties of the Turkish adaptation of the Mathematics Teacher Efficacy Belief Instrument for in-service teachers.

    Science.gov (United States)

    Cetinkaya, Bulent; Erbas, Ayhan Kursat

    2011-11-01

    Teaching efficacy beliefs have attracted researchers' attention in recent decades because of its close association with and potential impact on the implementation of new ideas and skills in education. In the present study, we have explored the psychometric properties and construct validity of the Turkish adaptation of the Mathematics Teacher Efficacy Belief Instrument developed by Enochs, Smith, & Huinker (2000) for in-service mathematics teachers. The instrument distinguishes between two dimensions of efficacy beliefs for mathematics teachers: personal mathematics teaching efficacy and mathematics teaching outcome expectancy. The sample consisted of 1355 in-service elementary school teachers and middle school mathematics teachers from 368 schools. Exploratory and confirmatory factor analysis revealed a two-factor structure similar to that found in other studies. Also, scores from the two subscales indicated acceptable internal consistency.

  12. Confiabilidade do Instrumento para Classificação de Idosos quanto à Capacidade para o Autocuidado Reliability of the Instrument for Classifying Elderly People's Capacity for Self-care

    Directory of Open Access Journals (Sweden)

    Maria Helena Morgani de Almeida

    2008-04-01

    Full Text Available OBJETIVO: Avaliar a confiabilidade do Instrumento para Classificação de Idosos quanto à Capacidade para o Autocuidado, desenvolvido para auxiliar o terapeuta ocupacional na atenção a idosos em unidades básicas de saúde. MÉTODOS: Foram realizados testes de estabilidade e consistência interna. Para validação do Instrumento, os testes foram aplicados à amostra de 30 indivíduos com 60 anos ou mais, em dois momentos. A análise estatística foi realizada a partir de agrupamentos criteriosos de respostas, o que levou à formulação de uma versão simplificada do Instrumento. A estabilidade desta versão foi avaliada pelo coeficiente kappa e a consistência interna pelo coeficiente alpha de Cronbach. RESULTADOS: A estabilidade variou de moderada a excelente. A consistência interna foi verificada somente para áreas que se mostraram adequadas para o uso da metodologia baseada no cálculo do alpha de Cronbach: três das seis questões da área "perfil social" e os blocos das atividades básicas e instrumentais de vida diária da área "capacidade funcional", respectivamente com nove e oito atividades. CONCLUSÕES: Após os testes de estabilidade e consistência interna, o Instrumento possibilita classificação sucinta e simplificada de idosos quanto à capacidade funcional para atividades básicas e instrumentais e sua caracterização quanto aos demais aspectos do autocuidado. Evidências acerca de sua confiabilidade e validade podem ser ampliadas por meio de novos estudos.OBJECTIVE: To evaluate the reliability of an instrument for classifying elderly people regarding their capacity for self-care, which was developed to assist occupational therapists in attending elderly people at primary healthcare units. METHODS: Stability and internal consistency tests were carried out. To validate the instrument, tests were applied to a sample of 30 individuals aged 60 years and over, on two occasions. The statistical analysis was performed after

  13. The Right to strike: International and regional legal instruments with accent of legislation in Republic of Macedonia

    OpenAIRE

    Majhosev, Andon; Denkova, Jadranka

    2013-01-01

    The right to strike is a universal democratic right of all employees, regardless of where they are employed: Real or public sector. Depending on the degree of realization of this right in a state, it is accordingly evaluated on the scale of democracy. Therefore, we can say that the right to strike is a fundamental measure of democratic values of a society. There is no real democracy without the right to strike. The right to strike is governed by international legal instruments (acts) of the U...

  14. Proceedings of a workshop on methods for neutron scattering instrumentation design

    International Nuclear Information System (INIS)

    Hjelm, R.P.

    1997-09-01

    The future of neutron and x-ray scattering instrument development and international cooperation was the focus of the workshop. The international gathering of about 50 participants representing 15 national facilities, universities and corporations featured oral presentations, posters, discussions and demonstrations. Participants looked at a number of issues concerning neutron scattering instruments and the tools used in instrument design. Objectives included: (1) determining the needs of the neutron scattering community in instrument design computer code and information sharing to aid future instrument development, (2) providing for a means of training scientists in neutron scattering and neutron instrument techniques, and (3) facilitating the involvement of other scientists in determining the characteristics of new instruments that meet future scientific objectives, and (4) fostering international cooperation in meeting these needs. The scope of the meeting included: (1) a review of x-ray scattering instrument design tools, (2) a look at the present status of neutron scattering instrument design tools and models of neutron optical elements, and (3) discussions of the present and future needs of the neutron scattering community. Selected papers were abstracted separately for inclusion to the Energy Science and Technology Database

  15. Proceedings of a workshop on methods for neutron scattering instrumentation design

    Energy Technology Data Exchange (ETDEWEB)

    Hjelm, R.P. [ed.] [Los Alamos National Lab., NM (United States)

    1997-09-01

    The future of neutron and x-ray scattering instrument development and international cooperation was the focus of the workshop. The international gathering of about 50 participants representing 15 national facilities, universities and corporations featured oral presentations, posters, discussions and demonstrations. Participants looked at a number of issues concerning neutron scattering instruments and the tools used in instrument design. Objectives included: (1) determining the needs of the neutron scattering community in instrument design computer code and information sharing to aid future instrument development, (2) providing for a means of training scientists in neutron scattering and neutron instrument techniques, and (3) facilitating the involvement of other scientists in determining the characteristics of new instruments that meet future scientific objectives, and (4) fostering international cooperation in meeting these needs. The scope of the meeting included: (1) a review of x-ray scattering instrument design tools, (2) a look at the present status of neutron scattering instrument design tools and models of neutron optical elements, and (3) discussions of the present and future needs of the neutron scattering community. Selected papers were abstracted separately for inclusion to the Energy Science and Technology Database.

  16. Instrument calibration optimization at Bruce Power: ECI loops

    International Nuclear Information System (INIS)

    Chugh, V.; Angelova, M.; Ghias, S.; Parmar, R.; Wang, V.; Xie, H.; Higgs, J.; Schut, J.; Cruchley, I.

    2011-01-01

    Most instruments in a nuclear power plant are calibrated at regular intervals to ensure consistency with the assumptions in the plant Technical Specifications and/or Safe Operating Envelope (SOE) compliance limits (e.g., As-Found Tolerance). In the Instrument Uncertainty Calculations (IUC), As-Found Tolerance for instrument drift is estimated based on statistical analysis of As-Found and As-Left calibration data such as that carried out for Bruce NGS by EPRI (Electric Power Research Institute) in 1998. Bruce specific drift values were found to compare favorably with industry benchmarks. Recently a significant amount of work has been done by EPRI and IAEA (International Atomic Energy Agency) on extending calibration intervals of safety related instruments. Reduction in calibration frequency reduces time commitments on the part of Authorized Nuclear Operators and safety system qualified Control Maintenance Technicians, and allows more schedule flexibility. To establish the proof of concept, As-Left/As-Found tolerances and available margins have been evaluated for the Bruce B Emergency Coolant Injection (ECI) system instrument loops to determine whether an extension of the calibration period from one or two year to three years is justifiable on the basis that these loops will still be in compliance with SOE. The analysis showed that 60% of instruments in the ECI system are qualified for calibration interval extension up to three years. Sensitivity assessment of the effect of proposed changes in calibration intervals for 60% of the instruments on the ECI system unavailability has also been performed using the current Bruce Power ECI unavailability model. The results show that, the largest ECI Predicted Future Unavailability (PFU) is 9.2E-4 year/year for in-core LOCA accident. This value is still below the target unavailability of 1.0E-3 year/year. (author)

  17. Instrument calibration optimization at Bruce Power: ECI loops

    Energy Technology Data Exchange (ETDEWEB)

    Chugh, V.; Angelova, M.; Ghias, S.; Parmar, R.; Wang, V.; Xie, H. [AMEC NSS, Toronto, Ontario (Canada); Higgs, J.; Schut, J.; Cruchley, I. [Bruce Power, Tiverton, Ontario (Canada)

    2011-07-01

    Most instruments in a nuclear power plant are calibrated at regular intervals to ensure consistency with the assumptions in the plant Technical Specifications and/or Safe Operating Envelope (SOE) compliance limits (e.g., As-Found Tolerance). In the Instrument Uncertainty Calculations (IUC), As-Found Tolerance for instrument drift is estimated based on statistical analysis of As-Found and As-Left calibration data such as that carried out for Bruce NGS by EPRI (Electric Power Research Institute) in 1998. Bruce specific drift values were found to compare favorably with industry benchmarks. Recently a significant amount of work has been done by EPRI and IAEA (International Atomic Energy Agency) on extending calibration intervals of safety related instruments. Reduction in calibration frequency reduces time commitments on the part of Authorized Nuclear Operators and safety system qualified Control Maintenance Technicians, and allows more schedule flexibility. To establish the proof of concept, As-Left/As-Found tolerances and available margins have been evaluated for the Bruce B Emergency Coolant Injection (ECI) system instrument loops to determine whether an extension of the calibration period from one or two year to three years is justifiable on the basis that these loops will still be in compliance with SOE. The analysis showed that 60% of instruments in the ECI system are qualified for calibration interval extension up to three years. Sensitivity assessment of the effect of proposed changes in calibration intervals for 60% of the instruments on the ECI system unavailability has also been performed using the current Bruce Power ECI unavailability model. The results show that, the largest ECI Predicted Future Unavailability (PFU) is 9.2E-4 year/year for in-core LOCA accident. This value is still below the target unavailability of 1.0E-3 year/year. (author)

  18. Novel mass spectrometric instrument for gaseous and particulate characterization and monitoring

    International Nuclear Information System (INIS)

    Coggiola, M.J.

    1993-04-01

    Under contract DE-AC21-92MC29116, SRI International will develop a unique new instrument that will be capable of providing real-time (< l minute), quantitative, chemical characterization of gaseous and particulate pollutants generated from DOE waste cleanup activities. The instrument will be capable of detecting and identifying volatile organic compounds, polynuclear aromatic hydrocarbons, heavy metals, and transuranic species released during waste cleanup activities. The instrument will be unique in its ability to detect and quantify in real-time these diverse pollutants in both vapor and particulate form. The instrument to be developed under this program will consist of several major components: (1) an isokinetic sampler capable of operating over a wide range of temperatures (up to 500 K) and flow rates; (2) a high pressure to low pressure transition and sampling region that efficiently separates particles from vapor-phase components for separate, parallel analyses; (3) two small mass spectrometers, one optimized for organic analysis using a unique field ionization source and one optimized for particulate characterization using thermal pyrolysis and electron-impact ionization (EI); and (4) a powerful personal computer for control and data acquisition

  19. 26 CFR 301.6224(c)-3 - Consistent settlements.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 18 2010-04-01 2010-04-01 false Consistent settlements. 301.6224(c)-3 Section... settlements. (a) In general. If the Internal Revenue Service enters into a settlement agreement with any..., settlement terms consistent with those contained in the settlement agreement entered into. (b) Requirements...

  20. Aspects of progress in neutron instrumentation

    International Nuclear Information System (INIS)

    Carlile, C.J.

    1999-01-01

    The capability of neutron instrumentation in coming years will depend upon many factors, the main ones being the neutron source the instrument is sited on, the quality of the instrument itself, the quality of the support provided and the protocol for instrument operation. All of these factors must be optimised and improved upon to ensure consistently high quality scientific exploitation of an instrument. Examples of progress in each of these fields are given and a subjective view of possible future trends are hazarded. (author)

  1. The Ostomy-Q: Development and Psychometric Validation of an Instrument to Evaluate Outcomes Associated with Ostomy Appliances.

    Science.gov (United States)

    Nafees, Beenish; Rasmussen, Mikkel; LLoyd, Andrew

    2017-01-01

    Using an ostomy appliance can affect many aspects of a person's health-related quality of life (HRQL). A 2-part, descrip- tive study was designed to develop and validate an instrument to assess quality-of-life outcomes related to ostomy ap- pliance use. Study inclusion/exclusion criteria stipulated participants should be 18 to 85 years of age, have an ileostomy or colostomy, used an appliance for a minimum of 3 months without assistance, and able to complete an online survey. All participants provided sociodemographic and clinical information. In phase 1, a literature search was conducted and existing instruments used to measure HRQL in persons with an ostomy were assessed. Subsequently, the Ostomy-Q, a 23-item, Likert-response type questionnaire, divided into 4 domains (Discreetness, Comfort, Confidence, and Social Life), was developed based on published evidence and existing ostomy-related HRQL tools. Seven (7) participants re- cruited from a manufacturer user panel took part in exploratory/cognitive qualitative interviews to refine the new quality- of-life questionnaire. In phase 2, the instrument was tested to assess item variability and conceptual structure, item-total correlation, internal consistency, test-retest reliability, sensitivity, and minimal important difference (MID) in an online validation study among 200 participants from the manufacturer's user panel (equally divided by gender, 125 [62.5%] >50 years old, 128 [64%] with an ileostomy). This exercise also included completion of the Stoma Quality of Life Question- naire and 2 domains from the Ostomy Adjustment Inventory-23 to assess convergent validity. Eighty-two (82) participants recompleted these study instruments 2 weeks later to assess test-retest reliability. Sociodemographic and clinical data were assessed using descriptive statistics; Cronbach's alpha was used for internal consistency (minimum 0.70), principle component analysis for item variability/conceptual structure, and item

  2. Modernization of instrumentation and control in nuclear power plants. Report prepared within the framework of the International Working Group on Nuclear Power Plant Control and Instrumentation

    International Nuclear Information System (INIS)

    1998-05-01

    The scope of the modernization activities described in this report includes the modernization of equipment in operating plants and partially built plants. It covers the full range of types of instrumentation and control (I and C) systems including protection, safety, control and information systems. It is applicable for a plant throughout its life. The report includes appropriate consideration of the increasingly international nature of the I and C systems supply industry and takes advantage of the activities and lessons learned in the different national approaches to develop general guidance and recommendations. An Annex includes 10 country reports which were separately indexed

  3. International multiphase mixed methods study protocol to develop a cross-cultural patient-reported outcome instrument for children and young adults with cleft lip and/or palate (CLEFT-Q).

    Science.gov (United States)

    Wong Riff, Karen W Y; Tsangaris, Elena; Goodacre, Tim; Forrest, Christopher R; Pusic, Andrea L; Cano, Stefan J; Klassen, Anne F

    2017-01-11

    Patient-reported outcome (PRO) instruments should be developed according to rigorous guidelines in order to provide clinically meaningful, scientifically sound measurement. Understanding the methodology behind instrument development informs the selection of the most appropriate tool. This mixed methods protocol describes the development of an internationally applicable PRO instrument, the CLEFT-Q, for evaluating outcomes of treatment for cleft lip and/or palate (CL/P). The study includes three main phases that occur iteratively and interactively. In phase I, we determine what concepts are important to patients regarding their outcome. A conceptual framework for the CLEFT-Q is formed through a systematic review and an extensive international qualitative study. The systematic review ascertains what concepts have previously been measured in patients with CL/P. The qualitative study employs interpretive description and involves in-depth interviews with patients in high-income and lower-middle income countries. Preliminary items are generated from the qualitative data. Preliminary scales are then created for each theme in the framework. Cognitive debriefing interviews and expert clinician input are used to refine the scales in an iterative process. In phase II, the preliminary scales are administered to a large international group of patients with CL/P. The modern psychometric method of Rasch Measurement Theory analysis is employed to define the measurement characteristics. The preliminary scales are shortened based on these results. In phase III, further tests assess reliability, validity and responsiveness of the instrument. The study is approved by Research Ethics Boards for each participating site. Findings from this study will be published in open access peer-reviewed journals and presented at national and international conferences. Integrated knowledge translation is employed to engage stakeholders from the outset of the study. Successful execution of the CLEFT

  4. Numerical tools for musical instruments acoustics: analysing nonlinear physical models using continuation of periodic solutions

    OpenAIRE

    Karkar , Sami; Vergez , Christophe; Cochelin , Bruno

    2012-01-01

    International audience; We propose a new approach based on numerical continuation and bifurcation analysis for the study of physical models of instruments that produce self- sustained oscillation. Numerical continuation consists in following how a given solution of a set of equations is modified when one (or several) parameter of these equations are allowed to vary. Several physical models (clarinet, saxophone, and violin) are formulated as nonlinear dynamical systems, whose periodic solution...

  5. Authentication of nuclear-material assays made with in-plant instruments

    International Nuclear Information System (INIS)

    Hatcher, C.R.; Hsue, S.T.; Russo, P.A.

    1982-01-01

    This paper develops a general approach for International Atomic Energy Agency (IAEA) authentication of nuclear material assays made with in-plant instruments under facility operator control. The IAEA is evaluating the use of in-plant instruments as a part of international safeguards at large bulk-handling facilities, such as reprocessing plants, fuel fabrication plants, and enrichment plants. One of the major technical problems associated with IAEA use of data from in-plant instruments is the need to show that there has been no tampering with the measurements. Two fundamentally different methods are discussed that can be used by IAEA inspectors to independently verify (or authenticate) measurements made with in-plant instruments. Method 1, called external authentication, uses a protected IAEA measurement technique to compare in-plant instrument results with IAEA results. Method 2, called internal authentication, uses protected IAEA standards, known physical constants, and special test procedures to determine the performance characteristics of the in-plant instrument. The importance of measurement control programs to detect normally expected instrument failures and procedural errors is also addressed. The paper concludes with a brief discussion of factors that should be considered by the designers of new in-plant instruments in order to facilitate IAEA authentication procedures

  6. Investigation of four self-report instruments (FABT, TSK-HC, Back-PAQ, HC-PAIRS) to measure healthcare practitioners' attitudes and beliefs toward low back pain: Reliability, convergent validity and survey of New Zealand osteopaths and manipulative physiotherapists.

    Science.gov (United States)

    Moran, Robert W; Rushworth, Wendy M; Mason, Jesse

    2017-12-01

    Healthcare practitioner beliefs influence advice and management provided to patients with back pain. Several instruments measuring practitioner beliefs have been developed but psychometric properties for some have not been investigated. To investigate internal consistency, test-retest reliability and convergent validity of the Fear Avoidance Beliefs Tool (FABT), the Tampa Scale of Kinesiophobia for Health Care Providers (TSK-HC), the Back Pain Attitudes Questionnaire (Back-PAQ), and the Health Care Pain and Impairment Relationship Scale (HC-PAIRS). A secondary aim was to explore beliefs of New Zealand osteopaths and physiotherapists regarding low back pain. FABT, TSK-HC, Back-PAQ, and HC-PAIRS were administered twice, 14 days apart. Data from 91 osteopaths and 35 physiotherapists were analysed. The FABT, TSK-HC and Back-PAQ each demonstrated excellent internal consistency, (Cronbach's α = 0.92, 0.91, and 0.91 respectively), and excellent test-retest reliability (lower limit of 95% CI for intraclass correlation coefficient >0.75). Correlations between instruments (Pearson's r = 0.51 to 0.77, p  0.47) for mean differences in scores, for all instruments, between professions. This study found excellent internal consistency, test-retest reliability and good convergent validity for the FABT, TSK-HC, and Back-PAQ. Previously reported internal consistency, test-retest and convergent validity of the HC-PAIRS were confirmed, and test-retest reliability was excellent. There were significant scoring differences on each instrument between professions, and while both groups demonstrated fear avoidant beliefs, physiotherapist respondent scores indicated that as a group, they held fewer fear-avoidant beliefs than osteopath respondents. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Protocol of the COSMIN study: COnsensus-based Standards for the selection of health Measurement INstruments

    Directory of Open Access Journals (Sweden)

    Patrick DL

    2006-01-01

    Full Text Available Abstract Background Choosing an adequate measurement instrument depends on the proposed use of the instrument, the concept to be measured, the measurement properties (e.g. internal consistency, reproducibility, content and construct validity, responsiveness, and interpretability, the requirements, the burden for subjects, and costs of the available instruments. As far as measurement properties are concerned, there are no sufficiently specific standards for the evaluation of measurement properties of instruments to measure health status, and also no explicit criteria for what constitutes good measurement properties. In this paper we describe the protocol for the COSMIN study, the objective of which is to develop a checklist that contains COnsensus-based Standards for the selection of health Measurement INstruments, including explicit criteria for satisfying these standards. We will focus on evaluative health related patient-reported outcomes (HR-PROs, i.e. patient-reported health measurement instruments used in a longitudinal design as an outcome measure, excluding health care related PROs, such as satisfaction with care or adherence. The COSMIN standards will be made available in the form of an easily applicable checklist. Method An international Delphi study will be performed to reach consensus on which and how measurement properties should be assessed, and on criteria for good measurement properties. Two sources of input will be used for the Delphi study: (1 a systematic review of properties, standards and criteria of measurement properties found in systematic reviews of measurement instruments, and (2 an additional literature search of methodological articles presenting a comprehensive checklist of standards and criteria. The Delphi study will consist of four (written Delphi rounds, with approximately 30 expert panel members with different backgrounds in clinical medicine, biostatistics, psychology, and epidemiology. The final checklist will

  8. Five-Item Francis Scale of Attitude toward Christianity: Construct and Nomological Validity and Internal Consistency among Colombian College Students

    Science.gov (United States)

    Ceballos, Guillermo A.; Suescun, Jesus D.; Oviedo, Heidi C.; Herazo, Edwin; Campo-Arias, Adalberto

    2015-01-01

    The Spanish version of the five-item Francis scale of attitude toward Christianity is a refinement of the short version of the Francis scale of attitude toward Christianity. The scale is a good measurement for intrinsic religiosity. It has been applied previously among Colombian adolescent students. The internal consistency and construct and…

  9. Good practices in normal childbirth: reliability analysis of an instrument by Cronbach's Alpha.

    Science.gov (United States)

    Gottems, Leila Bernarda Donato; Carvalho, Elisabete Mesquita Peres De; Guilhem, Dirce; Pires, Maria Raquel Gomes Maia

    2018-01-01

    to analyze the internal consistency of the evaluation instrument of the adherence to the good practices of childbirth and birth care in the professionals, through Cronbach's Alpha Coefficient for each of the dimensions and for the total instrument. this is a descriptive and cross-sectional study performed in obstetric centers of eleven public hospitals in the Federal District, with a questionnaire applied to 261 professionals who worked in the delivery care. The study was attended by 261 professionals, 42.5% (111) nurses and 57.5% (150) physicians. The reliability evaluation of the instrument by the Cronbach Alfa resulted in 0.53, 0.78 and 0.76 for dimensions 1, 2 and 3, after debugging that resulted in the exclusion of 11 items. the instrument obtained Cronbach's alpha of 0.80. There is a need for improvement in the items of dimension 1 that refer to attitudes, knowledge, and practices of the organization of the network of care to gestation, childbirth, and birth. However, it can be applied in the way it is used to evaluate practices based on scientific evidence of childbirth care.

  10. Regulatory requirements and quality assurance of radiation monitoring instruments

    International Nuclear Information System (INIS)

    Narasimharao, K.L.; Sharma, Ranjit

    2005-01-01

    The successful utilisation of radiation sources in the fields of medicine and industry requires the accurate measurement of activity, exposure rate and dose. Many varieties of instruments are in use for measurement of these parameters and new ones are being developed. The criteria for the design of the radiation monitoring instrument include the type and intensity of the radiation, purpose of measurement and ruggedness of the instrument. Quality and reliability of radiation monitoring instruments ensure that individuals are adequately protected. Accuracy, response time and ruggedness are required to be as per the approved/ prescribed guidelines. Regulatory authorities outline the design and performance criteria for radiation monitoring instruments and prescribe the recommendations of international agencies such as IAEA, ICRU and ISO for radiological measurement assurance programme. National Standards Laboratories all over the world prescribe procedures for calibration of various radiation monitoring instruments. The instruments should be calibrated as per these guidelines and should be traceable to national standards. The calibration traceable to national/ international standards and documentation as well as limits stipulated by the competent authority ensures the expected performance of the instrument. (author)

  11. Economic instruments for environmental mitigation

    International Nuclear Information System (INIS)

    Wilkinson, A.

    1995-01-01

    A joint International Chamber of Commerce (ICC)/World Energy Council (WEC) Working Group has been studying a range of policy instruments which are being used or considered for use to address the question of ever increasing energy demand versus environmental protection, and pollution reduction. Economic instruments for such environmental protection include direct regulation, market-based instruments, and voluntary approaches. No single policy or device was likely to suffice in addressing the diversity of environmental problems currently faced. Altering energy prices must be seen in a social context, but some direct regulation may also be inevitable. Generally economic instruments of change were preferred as these were viewed as more flexible and cost-effective. (UK)

  12. Deformation and fracture of K3 rotary nickel-titanium endodontic instruments after clinical use.

    Science.gov (United States)

    Shen, S M; Deng, M; Wang, P P; Chen, X M; Zheng, L W; Li, H L

    2016-11-01

    The aim was to evaluate the incidence and type of defects that occurred with K3 rotary nickel-titanium instruments during routine clinical use. A total of 2397 K3 (G-PACKS, SybronEndo, West Collins, Orange, CA, USA) instruments were collected from a graduate endodontic clinic over 21 months. All the instruments were limited to a maximum use of 30 canal preparations. The collected instruments were measured by a digital caliper to determine whether any fractures had occurred and then were visually inspected for deformation and fracture under a stereomicroscope. The surfaces of fractured instruments were further evaluated under a scanning electron microscope. Data were analysed using chi-square test and Kruskal-Wallis test. The incidence of instrument defect was 5.63%, consisting of 3.59% fractures and 2.05% deformations. The defect rates of 0.04 and 0.06 files were statistically higher than the other taper groups (P  0.05). For the fractured instruments, 63.95% failed from flexural fatigue, whilst 36.05% failed from torsion. Flexural fracture was the major mode of fracture for instruments with larger taper. A routine check for instrument integrity particularly for 0.04 and 0.06 files at high magnification is recommended after each clinical use. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  13. Nuclear measurements, techniques and instrumentation industrial applications plasma physics and nuclear fusion. 1980-1994. International Atomic Energy Agency publications

    International Nuclear Information System (INIS)

    1995-04-01

    This catalogue lists all sales publications of the International Atomic Energy Agency dealing with Nuclear Measurements, Techniques and Instrumentation, with Industrial Applications (of Nuclear Physics and Engineering), and with Plasma Physics and Nuclear Fusion, issued during the period 1980-1994. Most publications are in English. Proceedings of conferences, symposia, and panels of experts may contain some papers in other languages (French, Russian, or Spanish), but all papers have abstracts in English. Price quotes are in Austrian Schillings, do not include local taxes, and are subject to change without notice. Contents cover the three main categories of (i) Nuclear Measurements, Techniques and Instrumentation (Physics, Chemistry, Dosimetry Techniques, Nuclear Analytical Techniques, Research Reactors and Particle Accelerator Applications, Nuclear Data); (ii) Industrial Applications (Radiation Processing, Radiometry, Tracers); and (iii) Plasma Physics and Nuclear Fusion

  14. Nuclear measurements, techniques and instrumentation industrial applications plasma physics and nuclear fusion, 1980-1993. International Atomic Energy Agency publications

    International Nuclear Information System (INIS)

    1994-01-01

    This catalogue lists all sales publications of the International Atomic Energy Agency dealing with Nuclear Measurements, Techniques and Instrumentation, with Industrial Applications (of Nuclear Physics and Engineering), and with Plasma Physics and Nuclear Fusion, issued during the period 1980-1993. Most publications are in English. Proceedings of conferences, symposia, and panels of experts may contain some papers in other languages (French, Russian, or Spanish), but all papers have abstracts in English. Price quotes are in Austrian Schillings, do not include local taxes, and are subject to change without notice. Contents cover the three main categories of (I) Nuclear Measurements, Techniques and Instrumentation (Physics, Chemistry, Dosimetry Techniques, Nuclear Analytical Techniques, Research Reactors and Particle Accelerator Applications, Nuclear Data); (ii) Industrial Applications (Radiation Processing, Radiometry, Tracers); and (iii) Plasma Physics and Nuclear Fusion

  15. Measurement noise of a point autofocus surface topography instrument

    DEFF Research Database (Denmark)

    Feng, Xiaobing; Quagliotti, Danilo; Maculotti, Giacomo

    Optical instruments for areal topography measurement can be especially sensitive to noise when scanning is required. Such noise has different sources, including those internally generated and external sources from the environment.......Optical instruments for areal topography measurement can be especially sensitive to noise when scanning is required. Such noise has different sources, including those internally generated and external sources from the environment....

  16. Measuring attitude towards Buddhism and Sikhism : internal consistency reliability for two new instruments

    OpenAIRE

    Thanissaro, Phra Nicholas

    2011-01-01

    This paper describes and discusses the development and empirical properties of two new\\ud 24-item scales – one measuring attitude toward Buddhism and the other measuring attitude\\ud toward Sikhism. The scale is designed to facilitate inter-faith comparisons within the\\ud psychology of religion alongside the well-established Francis Scale of Attitude toward\\ud Christianity. Data were obtained from a multi-religious sample of 369 school pupils aged\\ud between 13 and 15 in London. Application of...

  17. GRIP LIGHTNING INSTRUMENT PACKAGE (LIP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Lightning Instrument Package (LIP) dataset was collected by the Lightning Instrument Package (LIP), which consists of 6 rotating vane type electric field...

  18. Consistent framework data for modeling and formation of scenarios in the Federal Environment Office; Konsistente Rahmendaten fuer Modellierungen und Szenariobildung im Umweltbundesamt

    Energy Technology Data Exchange (ETDEWEB)

    Weimer-Jehle, Wolfgang; Wassermann, Sandra; Kosow, Hannah [Internationales Zentrum fuer Kultur- und Technikforschung an der Univ. Stuttgart (Germany). ZIRN Interdisziplinaerer Forschungsschwerpunkt Risiko und Nachhaltige Technikentwicklung

    2011-04-15

    Model-based environmental scenarios normally require multiple framework assumptions regarding future social, political and economic developments (external developments). In most cases these framework assumptions are highly uncertain. Furthermore, different external developments are not isolated from each other and their interdependences can be described by qualitative judgments only. If the internal consistency of framework assumptions is not methodologically addressed, environmental models risk to be based on inconsistent combinations of framework assumptions which do not reflect existing relations between the respective factors in an appropriate way. This report aims at demonstrating how consistent context scenarios can be developed with the help of the cross-impact balance analysis (CIB). This method allows not only for the internal consistency of framework assumptions of a single model but also for the overall consistency of framework assumptions of modeling instruments, supporting the integrated interpretation of the results of different models. In order to demonstrate the method, in a first step, ten common framework assumptions were chosen and their possible future developments until 2030 were described. In a second step, a qualitative impact network was developed based on expert elicitation. The impact network provided the basis for a qualitative but systematic analysis of the internal consistency of combinations of framework assumptions. This analysis was carried out with the CIB-method and resulted in a set of consistent context scenarios. These scenarios can be used as an informative background for defining framework assumptions for environmental models at the UBA. (orig.)

  19. Proceedings of the International topical meeting on VVER instrumentation and control

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    The Proceedings contain the full texts of 44 contributions, out of which 42 have been input to INIS. The papers cover various aspects of WWER instrumentation and control including reactor upgrading and modernization, testing and refurbishment of instrumentation, and operational experience and problems. (A.K.).

  20. Proceedings of the International topical meeting on VVER instrumentation and control

    International Nuclear Information System (INIS)

    1997-11-01

    The Proceedings contain the full texts of 44 contributions, out of which 42 have been input to INIS. The papers cover various aspects of WWER instrumentation and control including reactor upgrading and modernization, testing and refurbishment of instrumentation, and operational experience and problems. (A.K.)

  1. Atomic absorption instrument functional description

    International Nuclear Information System (INIS)

    Bystroff, R.I.; Boyle, W.G. Jr.; Barton, G.W. Jr.

    1976-01-01

    This report describes a proposed system for automating atomic absorption analysis. The system consists of two atomic absorption instruments and an automatic sampler that can be attached to either instrument. A computer program controls the sampling and gathers data. The program then uses the data to perform bookkeeping, data processing, and report writing

  2. Developing and testing an instrument for identifying performance incentives in the Greek health care sector.

    Science.gov (United States)

    Paleologou, Victoria; Kontodimopoulos, Nick; Stamouli, Aggeliki; Aletras, Vassilis; Niakas, Dimitris

    2006-09-13

    In the era of cost containment, managers are constantly pursuing increased organizational performance and productivity by aiming at the obvious target, i.e. the workforce. The health care sector, in which production processes are more complicated compared to other industries, is not an exception. In light of recent legislation in Greece in which efficiency improvement and achievement of specific performance targets are identified as undisputable health system goals, the purpose of this study was to develop a reliable and valid instrument for investigating the attitudes of Greek physicians, nurses and administrative personnel towards job-related aspects, and the extent to which these motivate them to improve performance and increase productivity. A methodological exploratory design was employed in three phases: a) content development and assessment, which resulted in a 28-item instrument, b) pilot testing (N = 74) and c) field testing (N = 353). Internal consistency reliability was tested via Cronbach's alpha coefficient and factor analysis was used to identify the underlying constructs. Tests of scaling assumptions, according to the Multitrait-Multimethod Matrix, were used to confirm the hypothesized component structure. Four components, referring to intrinsic individual needs and external job-related aspects, were revealed and explain 59.61% of the variability. They were subsequently labeled: job attributes, remuneration, co-workers and achievement. Nine items not meeting item-scale criteria were removed, resulting in a 19-item instrument. Scale reliability ranged from 0.782 to 0.901 and internal item consistency and discriminant validity criteria were satisfied. Overall, the instrument appears to be a promising tool for hospital administrations in their attempt to identify job-related factors, which motivate their employees. The psychometric properties were good and warrant administration to a larger sample of employees in the Greek healthcare system.

  3. Developing and testing an instrument for identifying performance incentives in the Greek health care sector

    Directory of Open Access Journals (Sweden)

    Paleologou Victoria

    2006-09-01

    Full Text Available Abstract Background In the era of cost containment, managers are constantly pursuing increased organizational performance and productivity by aiming at the obvious target, i.e. the workforce. The health care sector, in which production processes are more complicated compared to other industries, is not an exception. In light of recent legislation in Greece in which efficiency improvement and achievement of specific performance targets are identified as undisputable health system goals, the purpose of this study was to develop a reliable and valid instrument for investigating the attitudes of Greek physicians, nurses and administrative personnel towards job-related aspects, and the extent to which these motivate them to improve performance and increase productivity. Methods A methodological exploratory design was employed in three phases: a content development and assessment, which resulted in a 28-item instrument, b pilot testing (N = 74 and c field testing (N = 353. Internal consistency reliability was tested via Cronbach's alpha coefficient and factor analysis was used to identify the underlying constructs. Tests of scaling assumptions, according to the Multitrait-Multimethod Matrix, were used to confirm the hypothesized component structure. Results Four components, referring to intrinsic individual needs and external job-related aspects, were revealed and explain 59.61% of the variability. They were subsequently labeled: job attributes, remuneration, co-workers and achievement. Nine items not meeting item-scale criteria were removed, resulting in a 19-item instrument. Scale reliability ranged from 0.782 to 0.901 and internal item consistency and discriminant validity criteria were satisfied. Conclusion Overall, the instrument appears to be a promising tool for hospital administrations in their attempt to identify job-related factors, which motivate their employees. The psychometric properties were good and warrant administration to a larger

  4. The influence of parental concern on the utility of autism diagnostic instruments.

    Science.gov (United States)

    Havdahl, Karoline Alexandra; Bishop, Somer L; Surén, Pål; Øyen, Anne-Siri; Lord, Catherine; Pickles, Andrew; von Tetzchner, Stephen; Schjølberg, Synnve; Gunnes, Nina; Hornig, Mady; Lipkin, W Ian; Susser, Ezra; Bresnahan, Michaeline; Magnus, Per; Stenberg, Nina; Reichborn-Kjennerud, Ted; Stoltenberg, Camilla

    2017-10-01

    The parental report-based Autism Diagnostic Interview-Revised (ADI-R) and the clinician observation-based Autism Diagnostic Observation Schedule (ADOS) have been validated primarily in U.S. clinics specialized in autism spectrum disorder (ASD), in which most children are referred by their parents because of ASD concern. This study assessed diagnostic agreement of the ADOS-2 and ADI-R toddler algorithms in a more broadly based sample of 679 toddlers (age 35-47 months) from the Norwegian Mother and Child Cohort. We also examined whether parental concern about ASD influenced instrument performance, comparing toddlers identified based on parental ASD concern (n = 48) and parent-reported signs of developmental problems (screening) without a specific concern about ASD (n = 400). The ADOS cutoffs showed consistently well-balanced sensitivity and specificity. The ADI-R cutoffs demonstrated good specificity, but reduced sensitivity, missing 43% of toddlers whose parents were not specifically concerned about ASD. The ADI-R and ADOS dimensional scores agreed well with clinical diagnoses (area under the curve ≥ 0.85), contributing additively to their prediction. On the ADI-R, different cutoffs were needed according to presence or absence of parental ASD concern, in order to achieve comparable balance of sensitivity and specificity. These results highlight the importance of taking parental concern about ASD into account when interpreting scores from parental report-based instruments such as the ADI-R. While the ADOS cutoffs performed consistently well, the additive contributions of ADI-R and ADOS scores to the prediction of ASD diagnosis underscore the value of combining instruments based on parent accounts and clinician observation in evaluation of ASD. Autism Res 2017, 10: 1672-1686. © 2017 International Society for Autism Research, Wiley Periodicals, Inc. © 2017 International Society for Autism Research, Wiley Periodicals, Inc.

  5. GRIP LIGHTNING INSTRUMENT PACKAGE (LIP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Lightning Instrument Package (LIP) consists of 6 rotating vane type electric field sensors along with a central computer to record and monitor the instruments....

  6. Temporal and Geographic variation in the validity and internal consistency of the Nursing Home Resident Assessment Minimum Data Set 2.0.

    Science.gov (United States)

    Mor, Vincent; Intrator, Orna; Unruh, Mark Aaron; Cai, Shubing

    2011-04-15

    The Minimum Data Set (MDS) for nursing home resident assessment has been required in all U.S. nursing homes since 1990 and has been universally computerized since 1998. Initially intended to structure clinical care planning, uses of the MDS expanded to include policy applications such as case-mix reimbursement, quality monitoring and research. The purpose of this paper is to summarize a series of analyses examining the internal consistency and predictive validity of the MDS data as used in the "real world" in all U.S. nursing homes between 1999 and 2007. We used person level linked MDS and Medicare denominator and all institutional claim files including inpatient (hospital and skilled nursing facilities) for all Medicare fee-for-service beneficiaries entering U.S. nursing homes during the period 1999 to 2007. We calculated the sensitivity and positive predictive value (PPV) of diagnoses taken from Medicare hospital claims and from the MDS among all new admissions from hospitals to nursing homes and the internal consistency (alpha reliability) of pairs of items within the MDS that logically should be related. We also tested the internal consistency of commonly used MDS based multi-item scales and examined the predictive validity of an MDS based severity measure viz. one year survival. Finally, we examined the correspondence of the MDS discharge record to hospitalizations and deaths seen in Medicare claims, and the completeness of MDS assessments upon skilled nursing facility (SNF) admission. Each year there were some 800,000 new admissions directly from hospital to US nursing homes and some 900,000 uninterrupted SNF stays. Comparing Medicare enrollment records and claims with MDS records revealed reasonably good correspondence that improved over time (by 2006 only 3% of deaths had no MDS discharge record, only 5% of SNF stays had no MDS, but over 20% of MDS discharges indicating hospitalization had no associated Medicare claim). The PPV and sensitivity levels of

  7. Human Rights Treaties Are an Important Part of the "International Health Instrumentariam" Comment on "The Legal Strength of International Health Instruments - What It Brings to Global Health Governance?"

    Science.gov (United States)

    Forman, Lisa

    2017-10-02

    In their commentary, Haik Nikogosian and Ilona Kickbusch argue for the necessity of new binding international legal instruments for health to address complex health determinants and offer a cogent analysis of the implications of such treaties for future global health governance. Yet in doing so they pay no attention to the existing instrumentarium of international legally binding treaties relevant to health, in the form of human rights treaties. International human rights law has entrenched individual entitlements and state obligations in relation to individual and public health through iterative human rights treaties since 1946. These treaties offer normative specificity, institutional monitoring and the possibility of enforcement and accountability. If we are to build a new 'international health instrumentariam' we should not ignore existing and important tools that can assist in this endeavor. © 2018 The Author(s); Published by Kerman University of Medical Sciences. This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  8. Informal caregiving in COPD: A systematic review of instruments and their measurement properties.

    Science.gov (United States)

    Cruz, Joana; Marques, Alda; Machado, Ana; O'Hoski, Sachi; Goldstein, Roger; Brooks, Dina

    2017-07-01

    Increasing symptoms and activity restriction associated with COPD progression greatly impact on the lives of their informal caregivers, who play a vital role in maintaining their health. An understanding of this impact is important for clinicians to support caregivers and maintain a viable patient environment at home. This systematic review aimed to identify the instruments commonly used to assess informal caregiving in COPD and describe their measurement properties in this population. Searches were conducted in PubMed, Scopus, Web of Science, CINAHL and PsycINFO and in references of key articles, until November 2016 (PROSPERO: CRD42016041401). Instruments used to assess the impact of COPD on caregivers were identified and their properties described. Quality of studies was rated using the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. Quality of the measurement properties of instruments was rated as 'positive', 'negative' or 'indeterminate'. Patients cared for, had moderate to very severe COPD and the sample of caregivers ranged from 24 to 406. Thirty-five instruments were used in fifty studies to assess caregivers' psychological status and mood (9 instruments), burden/distress (12 instruments), quality of life (5 instruments) or other (9 instruments). Eighteen studies assessed the measurement properties of 21 instruments, most commonly hypothesis testing (known validity) and internal consistency. Study quality varied from 'poor' to 'fair' and with many properties rated as 'indeterminate'. Although several instruments have been used to assess the impact of COPD on caregivers, an increased understanding of their properties is needed before their widespread implementation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. The test of variables of attention (TOVA): Internal consistency (Q1 vs. Q2 and Q3 vs. Q4) in children with Attention Deficit/Hyperactivity Disorder (ADHD)

    Science.gov (United States)

    The internal consistency of the Test of Variables of Attention (TOVA) was examined in a cohort of 6- to 12-year-old children (N = 63) strictly diagnosed with ADHD. The internal consistency of errors of omission (OMM), errors of commission (COM), response time (RT), and response time variability (RTV...

  10. Policy consistency and the achievement of Nigeria's foreign policy ...

    African Journals Online (AJOL)

    This study is an attempt to investigate the policy consistency of Nigeria‟s foreign policy and to understand the basis for this consistency; and also to see whether peacekeeping/peace-enforcement is key instrument in the achievement of Nigeria‟s foreign policy goals. The objective of the study was to examine whether the ...

  11. Developing an instrument to measure effective factors on Clinical Learning.

    Science.gov (United States)

    Dadgaran, Ideh; Shirazi, Mandana; Mohammadi, Aeen; Ravari, Ali

    2016-07-01

    Although nursing students spend a large part of their learning period in the clinical environment, clinical learning has not been perceived by its nature yet. To develop an instrument to measure effective factors on clinical learning in nursing students. This is a mixed methods study performed in 2 steps. First, the researchers defined "clinical learning" in nursing students through qualitative content analysis and designed items of the questionnaire based on semi-structured individual interviews with nursing students. Then, as the second step, psychometric properties of the questionnaire were evaluated using the face validity, content validity, construct validity, and internal consistency evaluated on 227 students from fourth or higher semesters. All the interviews were recorded and transcribed, and then, they were analyzed using Max Qualitative Data Analysis and all of qualitative data were analyzed using SPSS 14. To do the study, we constructed the preliminary questionnaire containing 102 expressions. After determination of face and content validities by qualitative and quantitative approaches, the expressions of the questionnaire were reduced to 45. To determine the construct validity, exploratory factor analysis was applied. The results indicated that the maximum variance percentage (40.55%) was defined by the first 3 factors while the rest of the total variance percentage (59.45%) was determined by the other 42 factors. Results of exploratory factor analysis of this questionnaire indicated the presence of 3 instructor-staff, students, and educational related factors. Finally, 41 expressions were kept in 3 factor groups. The α-Cronbach coefficient (0.93) confirmed the high internal consistency of the questionnaire. Results indicated that the prepared questionnaire was an efficient instrument in the study of the effective factors on clinical learning as viewed by nursing students since it involves 41 expressions and properties such as instrument design based

  12. Developing an instrument to measure effective factors on clinical learning

    Directory of Open Access Journals (Sweden)

    IDEH DADGARAN

    2016-07-01

    Full Text Available Introduction: Although nursing students spend a large part of their learning period in the clinical environment, clinical learning has not been perceived by its nature yet. To develop an instrument to measure effective factors on clinical learning in nursing students. Methods: This is a mixed methods study performed in 2 steps. First, the researchers defined “clinical learning” in nursing students through qualitative content analysis and designed items of the questionnaire based on semi-structured individual interviews with nursing students. Then, as the second step, psychometric properties of the questionnaire were evaluated using the face validity, content validity, construct validity, and internal consistency evaluated on 227 students from fourth or higher semesters. All the interviews were recorded and transcribed, and then, they were analyzed using Max Qualitative Data Analysis and all of qualitative data were analyzed using SPSS 14. Results: To do the study, we constructed the preliminary questionnaire containing 102 expressions. After determination of face and content validities by qualitative and quantitative approaches, the expressions of the questionnaire were reduced to 45. To determine the construct validity, exploratory factor analysis was applied. The results indicated that the maximum variance percentage (40.55% was defined by the first 3 factors while the rest of the total variance percentage (59.45% was determined by the other 42 factors. Results of exploratory factor analysis of this questionnaire indicated the presence of 3 instructor-staff, students, and educational related factors. Finally, 41 expressions were kept in 3 factor groups. The α-Cronbach coefficient (0.93 confirmed the high internal consistency of the questionnaire. Conclusion: Results indicated that the prepared questionnaire was an efficient instrument in the study of the effective factors on clinical learning as viewed by nursing students since it

  13. Modernization of instrumentation and control in nuclear power plants. Report prepared within the framework of the International Working Group on Nuclear Power Plant Control and Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-05-01

    The scope of the modernization activities described in this report includes the modernization of equipment in operating plants and partially built plants. It covers the full range of types of instrumentation and control (I and C) systems including protection, safety, control and information systems. It is applicable for a plant throughout its life. The report includes appropriate consideration of the increasingly international nature of the I and C systems supply industry and takes advantage of the activities and lessons learned in the different national approaches to develop general guidance and recommendations. An Annex includes 10 country reports which were separately indexed Refs, figs, tabs

  14. [Three-dimensional finite element modeling and biomechanical simulation for evaluating and improving postoperative internal instrumentation of neck-thoracic vertebral tumor en bloc resection].

    Science.gov (United States)

    Qinghua, Zhao; Jipeng, Li; Yongxing, Zhang; He, Liang; Xuepeng, Wang; Peng, Yan; Xiaofeng, Wu

    2015-04-07

    To employ three-dimensional finite element modeling and biomechanical simulation for evaluating the stability and stress conduction of two postoperative internal fixed modeling-multilevel posterior instrumentation ( MPI) and MPI with anterior instrumentation (MPAI) with neck-thoracic vertebral tumor en bloc resection. Mimics software and computed tomography (CT) images were used to establish the three-dimensional (3D) model of vertebrae C5-T2 and simulated the C7 en bloc vertebral resection for MPI and MPAI modeling. Then the statistics and images were transmitted into the ANSYS finite element system and 20N distribution load (simulating body weight) and applied 1 N · m torque on neutral point for simulating vertebral displacement and stress conduction and distribution of motion mode, i. e. flexion, extension, bending and rotating. With a better stability, the displacement of two adjacent vertebral bodies of MPI and MPAI modeling was less than that of complete vertebral modeling. No significant differences existed between each other. But as for stress shielding effect reduction, MPI was slightly better than MPAI. From biomechanical point of view, two internal instrumentations with neck-thoracic tumor en bloc resection may achieve an excellent stability with no significant differences. But with better stress conduction, MPI is more advantageous in postoperative reconstruction.

  15. Construction and Validation of an Instrument to Measure Taiwanese Elementary Students' Attitudes toward Their Science Class

    Science.gov (United States)

    Wang, Tzu-Ling; Berlin, Donna

    2010-12-01

    The main purpose of this study is to develop a valid and reliable instrument for measuring the attitudes toward science class of fourth- and fifth-grade students in an Asian school culture. Specifically, the development focused on three science attitude constructs-science enjoyment, science confidence, and importance of science as related to science class experiences. A total of 265 elementary school students in Taiwan responded to the instrument developed. Data analysis indicated that the instrument exhibited satisfactory validity and reliability with the Taiwan population used. The Cronbach's alpha coefficient was 0.93 for the entire instrument indicating a satisfactory level of internal consistency. However, both principal component analysis and parallel analysis showed that the three attitude scales were not unique and should be combined and used as a general "attitudes toward science class" scale. The analysis also showed that there were no gender or grade-level differences in students' overall attitudes toward science class.

  16. Patient-reported outcomes instruments: bridging the gap between international copyright laws and common practice for developers and users--a case example.

    Science.gov (United States)

    Anfray, Caroline

    2009-12-01

    Copyright laws are intended to protect the rights of authors in their literary, scientific, and artistic works. The recent controversy about the standardized version of the Asthma Quality of Life Questionnaire between Elizabeth Juniper and Eirini Grammatopoulou et al. is an example of the difficulties inherent to copyright faced by developers and users of patient-reported outcome (PRO) instruments. This brief communication presents the basics of international copyright laws (i.e., the Berne Convention), the facts behind the controversy, and our analysis of the case based on our experience as a distributing center of PRO instruments. We conclude that better communication between developers and users would prevent most unfortunate complications and misunderstandings.

  17. Reliability, factor analysis and internal consistency calculation of the Insomnia Severity Index (ISI in French and in English among Lebanese adolescents

    Directory of Open Access Journals (Sweden)

    M. Chahoud

    2017-06-01

    Conclusion: The results of our analyses reveal that both English and French versions of the ISI scale have good internal consistency and are reproducible and reliable. Therefore, it can be used to assess the prevalence of insomnia in Lebanese adolescents.

  18. Adaptation of the international physical activity questionnarie for the elderly

    Directory of Open Access Journals (Sweden)

    Tânia R. Bertoldo Benedetti

    2010-09-01

    Full Text Available The International Physical Activity Questionnaire (IPAQ estimates the weekly energy expenditure for physical activities (PA. This instrument was validated for use with Brazilian older adults. The need to adapt the structure and application of the IPAQ arose from the difficulties of older adults to correctly measure the number of days, time and intensity of PA (domains during a normal week and the difficulties encountered by the interviewers in field research. The adapted IPAQ consists of five domains and 15 questions and is applied by interview because of the low educational level of Brazilian older adults. The instrument is applied in its long form to permit better discrimination of PA in each domain and refers to a normal week to help recall morning, afternoon and evening activities. In addition, it includes details about mild, moderate and vigorous intensity. The training of the interviewers is fundamental. The report of the IPAQ adapted for older adults should be delivered in minutes per week and should use the classification active (≤ 150 min/week. The IPAQ adapted for older adults is an international instrument that is valid for the Brazilian elderly population. The instrument is a noninvasive easily applied method of low cost that reaches large population groups, among other advantages.

  19. Building the BIKE: Development and Testing of the Biotechnology Instrument for Knowledge Elicitation (BIKE)

    Science.gov (United States)

    Witzig, Stephen B.; Rebello, Carina M.; Siegel, Marcelle A.; Freyermuth, Sharyn K.; Izci, Kemal; McClure, Bruce

    2014-10-01

    Identifying students' conceptual scientific understanding is difficult if the appropriate tools are not available for educators. Concept inventories have become a popular tool to assess student understanding; however, traditionally, they are multiple choice tests. International science education standard documents advocate that assessments should be reform based, contain diverse question types, and should align with instructional approaches. To date, no instrument of this type targeting student conceptions in biotechnology has been developed. We report here the development, testing, and validation of a 35-item Biotechnology Instrument for Knowledge Elicitation (BIKE) that includes a mix of question types. The BIKE was designed to elicit student thinking and a variety of conceptual understandings, as opposed to testing closed-ended responses. The design phase contained nine steps including a literature search for content, student interviews, a pilot test, as well as expert review. Data from 175 students over two semesters, including 16 student interviews and six expert reviewers (professors from six different institutions), were used to validate the instrument. Cronbach's alpha on the pre/posttest was 0.664 and 0.668, respectively, indicating the BIKE has internal consistency. Cohen's kappa for inter-rater reliability among the 6,525 total items was 0.684 indicating substantial agreement among scorers. Item analysis demonstrated that the items were challenging, there was discrimination among the individual items, and there was alignment with research-based design principles for construct validity. This study provides a reliable and valid conceptual understanding instrument in the understudied area of biotechnology.

  20. Crosslinguistic Developmental Consistency in the Composition of Toddlers’ Internal State Vocabulary: Evidence from Four Languages

    Directory of Open Access Journals (Sweden)

    Susanne Kristen

    2014-01-01

    Full Text Available Mental state language, emerging in the second and third years of life in typically developing children, is one of the first signs of an explicit psychological understanding. While mental state vocabulary may serve a variety of conversational functions in discourse and thus might not always indicate psychological comprehension, there is evidence for genuine references to mental states (desires, knowledge, beliefs, and emotions early in development across languages. This present study presents parental questionnaire data on the composition of 297 toddler-aged (30-to 32-month-olds children’s internal state vocabulary in four languages: Italian, German, English, and French. The results demonstrated that across languages expressions for physiological states (e.g., hungry and tired were among the most varied, while children’s vocabulary for cognitive entities (e.g., know and think proved to be least varied. Further, consistent with studies on children’s comprehension of these concepts, across languages children’s mastery of volition terms (e.g., like to do and want preceded their mastery of cognition terms. These findings confirm the cross-linguistic consistency of children’s emerging expression of abstract psychological concepts.

  1. Traceability of radiation protection instruments

    Science.gov (United States)

    Hino, Y.; Kurosawa, T.

    2007-08-01

    Radiation protection instruments are used in daily measurement of dose and activities in workplaces and environments for safety management. The requirements for calibration certificates with traceability are increasing for these instruments to ensure the consistency and reliabilities of the measurement results. The present traceability scheme of radiation protection instruments for dose and activity measurements is described with related IEC/ISO requirements. Some examples of desirable future calibration systems with recent new technologies are also discussed to establish the traceability with reasonable costs and reliabilities.

  2. Study of parental models: building an instrument for their exploration

    Directory of Open Access Journals (Sweden)

    José Francisco Martínez Licona

    2014-08-01

    Full Text Available Objective: This research presents the construction of an attributional questionnaire concerning the different parental models and factors that are involved in family interactions. Method: A mixed methodology was used as a foundation to develop items and respective pilots that allowed checking the validity and internal consistency of the instrument using expert judgment. Results: An instrument of 36 statements was organized into 12 categories to explore the parental models according to the following factors: parental models, breeding patterns, attachment bonds and guidelines for success, and promoted inside family contexts. Analyzing these factors contributes to the children’s development within the familiar frown, and the opportunity for socio-educational intervention. Conclusion: It is assumed that the family context is as decisive as the school context; therefore, exploring the nature of parental models is required to understand the features and influences that contribute to the development of young people in any social context.

  3. The positive mental health instrument: development and validation of a culturally relevant scale in a multi-ethnic asian population

    Directory of Open Access Journals (Sweden)

    Vaingankar Janhavi

    2011-10-01

    Full Text Available Abstract Background Instruments to measure mental health and well-being are largely developed and often used within Western populations and this compromises their validity in other cultures. A previous qualitative study in Singapore demonstrated the relevance of spiritual and religious practices to mental health, a dimension currently not included in exiting multi-dimensional measures. The objective of this study was to develop a self-administered measure that covers all key and culturally appropriate domains of mental health, which can be applied to compare levels of mental health across different age, gender and ethnic groups. We present the item reduction and validation of the Positive Mental Health (PMH instrument in a community-based adult sample in Singapore. Methods Surveys were conducted among adult (21-65 years residents belonging to Chinese, Malay and Indian ethnicities. Exploratory and confirmatory factor analysis (EFA, CFA were conducted and items were reduced using item response theory tests (IRT. The final version of the PMH instrument was tested for internal consistency and criterion validity. Items were tested for differential item functioning (DIF to check if items functioned in the same way across all subgroups. Results: EFA and CFA identified six first-order factor structure (General coping, Personal growth and autonomy, Spirituality, Interpersonal skills, Emotional support, and Global affect under one higher-order dimension of Positive Mental Health (RMSEA = 0.05, CFI = 0.96, TLI = 0.96. A 47-item self-administered multi-dimensional instrument with a six-point Likert response scale was constructed. The slope estimates and strength of the relation to the theta for all items in each six PMH subscales were high (range:1.39 to 5.69, suggesting good discrimination properties. The threshold estimates for the instrument ranged from -3.45 to 1.61 indicating that the instrument covers entire spectrums for the six dimensions. The

  4. THE RIGHT TO FORM AND TO JOIN TRADE UNIONS AS DEFINED IN INTERNATIONAL LEGAL INSTRUMENTS

    Directory of Open Access Journals (Sweden)

    Andon Majhoshev

    2017-07-01

    Full Text Available The right of workers to form and to join trade unions is one of the most important international labour standards. This means that employees, no matter where they are employed (public or private sector, have the right to form their own organizations (unions. Apart from the employees, employers also have the right to form and join in employers’ associations. The right of employees and employers to organize is based on the following principles: voluntariness, autonomy and democracy. The general objective of the formation of unions and employers’ associations is to protect the rights and interests of members of the union and the employers’ association, as well as their promotion in an organized manner. The provision and guarantee of union and workers' rights are guaranteed by a number of international and regional legal instruments (conventions, recommendations, regulations, such as ILO, UN, Council of Europe and the European Union, which will be analysed further in this paper. The main objective arising from these documents is to improve the position of workers and their protection. Within the paper, we will also analyse the most important legal acts of the Republic of Macedonia concerning the right to join unions. By analysing the content of the national labour legislation, we will determine the extent to which the international labour law is being implemented. Moreover, the paper will analyse the basic principles underlying union organization and association.

  5. Development and validation of a new condition-specific instrument for evaluation of smile esthetics-related quality of life.

    Science.gov (United States)

    Saltovic, Ema; Lajnert, Vlatka; Saltovic, Sabina; Kovacevic Pavicic, Daniela; Pavlic, Andrej; Spalj, Stjepan

    2018-03-01

    Orofacial esthetics raises psychosocial issues. The purpose was to create and validate new short instrument for psychosocial impacts of altered smile esthetics. A team of an orthodontist, two prosthodontists, psychologist, and a dental student generated items that could draw up specific hypothetical psychosocial dimensions (69 items initially, 39 in final analysis). The sample consisted of 261 Caucasian subjects attending local high schools and university (26% male) aged 14 to 28 years that have self-administrated the designed questionnaire. Factorial analysis, Cronbach's alpha, Pearson correlation, paired samples t-test and analysis of variance were used for analyses of internal consistency, construct validity, responsiveness, and test-retest. Three dimensions of psychosocial impacts of altered smile esthetics were identified: dental self-consciousness, dental self-confidence and social contacts that can be best fitted by 12 items, 4 items in each dimension. Internal consistency was good (α in range 0.85-0.89). Good stability in test-retest was confirmed. In responsiveness testing, tooth whitening induced increase in dental self-confidence (P = 0.002), but no significant changes in other dimensions. The new instrument, Smile Esthetics-Related Quality of Life (SERQoL), is short and has proven to be a good indicator of psychosocial dimensions related to perception of smile esthetics. Smile Esthetics-Related Quality of Life questionnaire might have practical validity when applied in esthetic dental clinical procedures. © 2017 Wiley Periodicals, Inc.

  6. ATLAS Facility and Instrumentation Description Report

    International Nuclear Information System (INIS)

    Kang, Kyoung Ho; Moon, Sang Ki; Park, Hyun Sik

    2009-06-01

    A thermal-hydraulic integral effect test facility, ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation), has been constructed at KAERI (Korea Atomic Energy Research Institute). The ATLAS is a half-height and 1/288-volume scaled test facility with respect to the APR1400. The fluid system of the ATLAS consists of a primary system, a secondary system, a safety injection system, a break simulating system, a containment simulating system, and auxiliary systems. The primary system includes a reactor vessel, two hot legs, four cold legs, a pressurizer, four reactor coolant pumps, and two steam generators. The secondary system of the ATLAS is simplified to be of a circulating looptype. Most of the safety injection features of the APR1400 and the OPR1000 are incorporated into the safety injection system of the ATLAS. In the ATLAS test facility, about 1300 instrumentations are installed to precisely investigate the thermal-hydraulic behavior in simulation of the various test scenarios. This report describes the scaling methodology, the geometric data of the individual component, and the specification and the location of the instrumentations which are specific to the simulation of 50% DVI line break accident of the APR1400 for supporting the 50 th OECD/NEA International Standard Problem Exercise (ISP-50)

  7. Instruments to assess self-care among healthy children: A systematic review of measurement properties.

    Science.gov (United States)

    Urpí-Fernández, Ana-María; Zabaleta-Del-Olmo, Edurne; Montes-Hidalgo, Javier; Tomás-Sábado, Joaquín; Roldán-Merino, Juan-Francisco; Lluch-Canut, María-Teresa

    2017-12-01

    To identify, critically appraise and summarize the measurement properties of instruments to assess self-care in healthy children. Assessing self-care is a proper consideration for nursing practice and nursing research. No systematic review summarizes instruments of measurement validated in healthy children. Psychometric review in accordance with the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) panel. MEDLINE, CINAHL, PsycINFO, Web of Science and Open Grey were searched from their inception to December 2016. Validation studies with a healthy child population were included. Search was not restricted by language. Two reviewers independently assessed the methodological quality of included studies using the COSMIN checklist. Eleven studies were included in the review assessing the measurement properties of ten instruments. There was a maximum of two studies per instrument. None of the studies evaluated the properties of test-retest reliability, measurement error, criterion validity and responsiveness. Internal consistency and structural validity were rated as "excellent" or "good" in four studies. Four studies were rated as "excellent" in content validity. Cross-cultural validity was rated as "poor" in the two studies (three instruments) which cultural adaptation was carried out. The evidence available does not allow firm conclusions about the instruments identified in terms of reliability and validity. Future research should focus on generate evidence about a wider range of measurement properties of these instruments using a rigorous methodology, as well as instrument testing on different countries and child population. © 2017 John Wiley & Sons Ltd.

  8. Development and initial validation of the Pharmacist Frequency of Interprofessional Collaboration Instrument (FICI-P) in primary care.

    Science.gov (United States)

    Van, Connie; Costa, Daniel; Mitchell, Bernadette; Abbott, Penny; Krass, Ines

    2012-01-01

    Existing validated measures of pharmacist-physician collaboration focus on measuring attitudes toward collaboration and do not measure frequency of collaborative interactions. To develop and validate an instrument to measure the frequency of collaboration between pharmacists and general practitioners (GPs) from the pharmacist's perspective. An 11-item Pharmacist Frequency of Interprofessional Collaboration Instrument (FICI-P) was developed and administered to 586 pharmacists in 8 divisions of general practice in New South Wales, Australia. The initial items were informed by a review of the literature in addition to interviews of pharmacists and GPs. Items were subjected to principal component and Rasch analyses to determine each item's and the overall measure's psychometric properties and for any needed refinements. Two hundred and twenty four (38%) of pharmacist surveys were completed and returned. Principal component analysis suggested removal of 1 item for a final 1-factor solution. The refined 10-item FICI-P demonstrated internal consistency reliability at Cronbach's alpha=0.90. After collapsing the original 5-point response scale to a 4-point response scale, the refined FICI-P demonstrated fit to the Rasch model. Criterion validity of the FICI-P was supported by the correlation of FICI-P scores with scores on a previously validated Physician-Pharmacist Collaboration Instrument. Validity was also supported by predicted differences in FICI-P scores between subgroups of respondents stratified on age, colocation with GPs, and interactions during the intern-training period. The refined 10-item FICI-P was shown to have good internal consistency, criterion validity, and fit to the Rasch model. The creation of such a tool may allow for the measure of impact in the evaluation of interventions designed to improve interprofessional collaboration between GPs and pharmacists. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. [Psychometric properties of Q-DIO, an instrument to measure the quality of documented nursing diagnoses, interventions and outcomes].

    Science.gov (United States)

    Müller-Staub, Maria; Lunney, Margaret; Lavin, Mary Ann; Needham, Ian; Odenbreit, Matthias; van Achterberg, Theo

    2010-04-01

    The instrument Q-DIO was developed in the years 2005 till 2006 to measure the quality of documented nursing diagnoses, interventions, and nursing sensitive patient outcomes. Testing psychometric properties of the Q-DIO (Quality of nursing Diagnoses, Interventions and Outcomes.) was the study aim. Instrument testing included internal consistency, test-retest reliability, interrater reliability, item analyses, and an assessment of the objectivity. To render variation in scores, a random strata sample of 60 nursing documentations was drawn. The strata represented 30 nursing documentations with and 30 without application of theory based, standardised nursing language. Internal consistency of the subscale nursing diagnoses as process showed Cronbach's Alpha 0.83 [0.78, 0.88]; nursing diagnoses as product 0.98 [0.94, 0.99]; nursing interventions 0.90 [0.85, 0.94]; and nursing-sensitive patient outcomes 0.99 [0.95, 0.99]. With Cohen's Kappa of 0.95, the intrarater reliability was good. The interrater reliability showed a Kappa of 0.94 [0.90, 0.96]. Item analyses confirmed the fulfilment of criteria for degree of difficulty and discriminative validity of the items. In this study, Q-DIO has shown to be a reliable instrument. It allows measuring the documented quality of nursing diagnoses, interventions and outcomes with and without implementation of theory based, standardised nursing languages. Studies for further testing of Q-DIO in other settings are recommended. The results implicitly support the use of nursing classifications such as NANDA, NIC and NOC.

  10. Lessons Learned From the Analysis of the SAFOD Downhole Instrument Package.

    Science.gov (United States)

    Johnson, Wade; Mencin, David; Mattioli, Glen

    2013-04-01

    In September of 2008 a downhole instrument package (DIP) consisting of a string of seismometers and tilt meters in isolated pressure vessels (PODs) was installed in the SAFOD main borehole. This package was designed to protect the sensors from the corrosive borehole environment and to operate for two years. The SAFOD borehole is not sealed at the bottom allowing borehole gasses and fluids infiltratration. Previous short-term installations of instruments in the SAFOD main borehole had also failed as a result of corrosion of the wireline cable head. The average failure time for these installations was two weeks. The use of stainless steel tubing connected to the pressure vessels through gas tight fittings was designed to block borehole fluid and gas infiltration of the individual instruments within the PODs. Unfortunately, the DIP completely failed within a month of its installation. In October of 2010, the DIP was removed from the borehole and a failure analysis was performed. This analysis involved to following steps: 1. Analysis of data to understand timeline of failure 2. Remove instrument safely, maintaining integrity of spliced section and documenting any external clues. Test instrument at surface 3. Open PODs in a way that allows for sampling and avoids damaging instruments. 4. Chemical analysis of fluids recovered from splices and PODs. 5. Instrument failure analysis by the instrument manufacturers. The analysis found that there were several design flaws in the DIP. This included the use of motor oil to take up air space in the individual PODs, use of a large number of gas tight seals, lack of internal seals, poorly done solder joints, use of non-temperature rated sensors, and lack of management oversight. The lessons learned from the attempts to instrument the SAFOD borehole are critical to the success of future deep borehole projects.

  11. The compatibility of flexible instruments under the Kyoto Protocol

    International Nuclear Information System (INIS)

    Jepma, C.J.; Van der Gaast, W.P.; Woerdman, E.

    1998-01-01

    The compatibility of the Kyoto Protocol flexible instruments and the lessons that can be learned form the AIJ-phase (AIJ stands for Activities Implemented Jointly) are discussed. The key point to be made is that there may be various applications of flexible instruments which can create situations where the various instruments would crowd out each other. On the other hand, applying flexible instruments may create a leverage for Parties in terms of achieving domestic environmental objectives. In addition, several issues related to the implementation of Joint Implementation (JI) , Clean Development Mechanism (CDM) and international emissions trading are discussed. The issues concern mainly those that have been included in the working programme on flexible instruments for CoP4 and CoP5 (CoP stands for Convention of Parties). As such the report discusses the consequences of possible negotiations outcomes at CoP for the effectiveness of flexible instruments, Parties' capabilities to achieve their Kyoto Protocol commitments cost-effectively, and the role of the private sector on the national and international credits markets(s). 106 refs

  12. Validation of the Family Meeting Behavioral Skills Checklist. An Instrument to Assess Fellows' Communication Skills.

    Science.gov (United States)

    Gustin, Jillian L; Way, David P; Wells-Di Gregorio, Sharla; McCallister, Jennifer W

    2016-08-01

    Fellows in pulmonary and critical care medicine are required to show competency in facilitating family meetings for critically ill patients. There are many assessment measures available for evaluating physician-patient communication (e.g., the SEGUE Framework [Set the stage, Elicit information, Give information, Understand the patient's perspective, End the encounter]) and some designed for family meetings. However, no validated measure exists that is specifically designed to assess communication skills during family meetings with surrogate decision makers in intensive care settings. We developed the Family Meeting Behavioral Skills Checklist (FMBSC) to measure advanced communication skills of fellows in family meetings of critically ill patients based on a literature review and consensus of an interdisciplinary group of communications experts. We evaluated the psychometric properties of the FMBSC. We digitally recorded 16 pulmonary/critical care fellows performing a simulated family meeting for a critically ill patient at the end of 1 year of fellowship training. Two clinical health psychologists evaluated each recording independently using the FMBSC Rating Scale and the SEGUE Framework. Judges recorded the number of skills performed using the checklist and employed a summary rating scale to judge the level of performance for each of nine subsets of skills. Each instrument was scored and converted to percentage scores. The FMBSC and SEGUE Framework items were summed and converted to percentage scores for each category and as a total for each instrument. The rating scale items on the FMBSC were also summed and converted to a percentage score. Four primary analyses were conducted to evaluate interjudge reliability, internal consistency, and concurrent validity. Interrater reliability was higher for the FMBSC (intraclass correlation [ICC2,2] = 0.57) than for the SEGUE instrument (ICC2,2 = 0.32) or the FMBSC Rating Scale (ICC2,2 = 0.23). The FMBSC

  13. Competitive effects and instruments of power sector reforms. International reform concepts blockade structures, risk distribution. A political economy analysis

    International Nuclear Information System (INIS)

    Liebchen, Armin

    2014-01-01

    Power sectors with weak or inadequate competition structures are the rule, despite numerous attempts at reform. But can afford modern economies this defect for a long time? Why can the implementation of competition are blocked so effectively? The author studied international reform experiences and opens up interesting insights that can also reflect on problems of the German energy turnaround: The difficulty of timing and coordination of the reform components, the development of resistance levels of individual interest groups, breach of contract as a rational alternative, causes unwanted price effects, shifting interest situations of major stakeholders, change dynamics impending regulatory risks, pending financing risks, stranded cost-conflict situations for power stations disconnected from the grid and facilities and instruments of a political and regulatory risk management for reforms. With numerous examples, background analyzes and instruments to reform analysis, this book is aimed at investors, policy planners and analysts. [de

  14. Development of an instrument to measure self-efficacy in caregivers of people with advanced cancer.

    Science.gov (United States)

    Ugalde, Anna; Krishnasamy, Meinir; Schofield, Penelope

    2013-06-01

    Informal caregivers of people with advanced cancer experience many negative impacts as a result of their role. There is a lack of suitable measures specifically designed to assess their experience. This study aimed to develop a new measure to assess self-efficacy in caregivers of people with advanced cancer. The development and testing of the new measure consisted of four separate, sequential phases: generation of issues, development of issues into items, pilot testing and field testing. In the generation of issues, 17 caregivers were interviewed to generate data. These data were analysed to generate codes, which were then systematically developed into items to construct the instrument. The instrument was pilot tested with 14 health professionals and five caregivers. It was then administered to a large sample for field testing to establish the psychometric properties, with established measures including the Brief Cope and the Family Appraisals for Caregiving Questionnaire for Palliative Care. Ninety-four caregivers completed the questionnaire booklet to establish the factor structure, reliability and validity. The factor analysis resulted in a 21-item, four-factor instrument, with the subscales being termed Resilience, Self-Maintenance, Emotional Connectivity and Instrumental Caregiving. The test-retest reliability and internal consistency were both excellent, ranging from 0.73 to 0.85 and 0.81 to 0.94, respectively. Six convergent and divergent hypotheses were made, and five were supported. This study has developed a new instrument to assess self-efficacy in caregivers of people with advanced cancer. The result is a four-factor, 21-item instrument with demonstrated reliability and validity. Copyright © 2012 John Wiley & Sons, Ltd.

  15. Safeguards instrument to monitor spent reactor fuel

    International Nuclear Information System (INIS)

    Nicholson, N.; Dowdy, E.J.; Holt, D.M.; Stump, C.

    1981-01-01

    A hand-held instrument for monitoring irradiated nuclear fuel inventories located in water-filled storage ponds has been developed. This instrument provides sufficient precise qualitative and quantitative information to be useful as a confirmatory technique to International Atomic Energy Agency inspectors, and is believed to be of potential use to nuclear fuel managers and to operators of spent-fuel storage facilities, both at reactor and away-from-reactor, and to operators of nuclear fuel reprocessing plants. Because the Cerenkov radiation glow can barely be seen by the unaided eye under darkened conditions, a night vision device is incorporated to aid the operator in locating the fuel assembly to be measured. Beam splitting optics placed in front of the image intensifier and a preset aperture select a predetermined portion of the observed scene for measurement of the light intensity using a photomultiplier (PM) tube and digital readout. The PM tube gain is adjusted by use of an internal optical reference source, providing long term repeatability and instrument-to-instrument cnsistency. Interchangeable lenses accommodate various viewing and measuring conditions

  16. Development and validation of an instrument to measure nurse educator perceived confidence in clinical teaching.

    Science.gov (United States)

    Nguyen, Van N B; Forbes, Helen; Mohebbi, Mohammadreza; Duke, Maxine

    2017-12-01

    Teaching nursing in clinical environments is considered complex and multi-faceted. Little is known about the role of the clinical nurse educator, specifically the challenges related to transition from clinician, or in some cases, from newly-graduated nurse to that of clinical nurse educator, as occurs in developing countries. Confidence in the clinical educator role has been associated with successful transition and the development of role competence. There is currently no valid and reliable instrument to measure clinical nurse educator confidence. This study was conducted to develop and psychometrically test an instrument to measure perceived confidence among clinical nurse educators. A multi-phase, multi-setting survey design was used. A total of 468 surveys were distributed, and 363 were returned. Data were analyzed using exploratory and confirmatory factor analyses. The instrument was successfully tested and modified in phase 1, and factorial validity was subsequently confirmed in phase 2. There was strong evidence of internal consistency, reliability, content, and convergent validity of the Clinical Nurse Educator Skill Acquisition Assessment instrument. The resulting instrument is applicable in similar contexts due to its rigorous development and validation process. © 2017 The Authors. Nursing & Health Sciences published by John Wiley & Sons Australia, Ltd.

  17. Validity and reliability of a Malay version of the Lawton instrumental activities of daily living scale among the Malay speaking elderly in Malaysia.

    Science.gov (United States)

    Kadar, Masne; Ibrahim, Suhaili; Razaob, Nor Afifi; Chai, Siaw Chui; Harun, Dzalani

    2018-02-01

    The Lawton Instrumental Activities of Daily Living Scale is a tool often used to assess independence among elderly at home. Its suitability to be used with the elderly population in Malaysia has not been validated. This current study aimed to assess the validity and reliability of the Lawton Instrumental Activities of Daily Living Scale - Malay Version to Malay speaking elderly in Malaysia. This study was divided into three phases: (1) translation and linguistic validity involving both forward and backward translations; (2) establishment of face validity and content validity; and (3) establishment of reliability involving inter-rater, test-retest and internal consistency analyses. Data used for these analyses were obtained by interviewing 65 elderly respondents. Percentages of Content Validity Index for 4 criteria were from 88.89 to 100.0. The Cronbach α coefficient for internal consistency was 0.838. Intra-class Correlation Coefficient of inter-rater reliability and test-retest reliability was 0.957 and 0.950 respectively. The result shows that the Lawton Instrumental Activities of Daily Living Scale - Malay Version has excellent reliability and validity for use with the Malay speaking elderly people in Malaysia. This scale could be used by professionals to assess functional ability of elderly who live independently in community. © 2018 Occupational Therapy Australia.

  18. Comparison of instrumental neutron activation analysis and instrumental charged-particle activation analysis for determining of Zn-68 abundance

    International Nuclear Information System (INIS)

    Rafii, H.; Mirzaei, M.; Aslani, G.R.; Kamali-Dehghan, M.; Rajamand, A-A.; Rahiminejad, A.; Mirzajani, N.; Sardari, D.; Shahabi, I.; Majidi, F.

    2004-01-01

    Gallium-67 has found important applications in nuclear medicine since last decades. The bombardment of enriched zinc-68 by proton beams in cyclotron is the most suitable method for the carrier-free production of this radionuclide. Any traces and isotopic impurities of the target cause serious radiological hazards because of their associated induced radioactivities. Trace analysis and Zn-68 content determination of the target material before any bombardment and chemical separation provide a valuable assessment of desired product. The elemental abundance evaluation of enriched isotopes is generally carried out by inductively coupled plasma-mass spectrometry method, ICP-Ms Instrumental neutron activation analysis and instrumental charged particle activation analysis. International neutron activation analysis and instrumental charged- particle activation analysis, looks be an alternative nuclear method for determining the abundance evaluation of enriched Zn-68 enrichment in two different samples has been studied by mean of international neutron activation analysis and instrumental charged- particle activation analysis . One sample was purchased from a French company, cortecnet, and the other was separated by an electromagnetic system in the Ions source department of our center, NRCAM. The neutron or proton irradiation was took place respectively in miniature neutron source reactor of Esfahan by flux of (1 to 5) 10 11 n/cm 2 .sec for 30 min and in Cyclon30 by 19 MeV proton beams of 100μA current for 12 min. The produced radioactivity was measured by HpGe detector for determination of trace impurities and evaluation of Zn-68 content in the samples. The result shows a good agreement with the reported ones by their producers and their low derivation of about ± indicates that the international neutron activation analysis and instrumental charged- particle activation analysis are relatively precise and rapid and each one can be used as a supplemental method for analyzing

  19. Validation of the "Quality of Life in School" instrument in Canadian elementary school students.

    Science.gov (United States)

    Ghotra, Satvinder; McIsaac, Jessie-Lee D; Kirk, Sara F L; Kuhle, Stefan

    2016-01-01

    Background. School is an integral component of the life of a child, and thus quality of school life is an important part of the overall quality of life experienced by a child. There are a few instruments available to measure the quality of school life but they are often not available in English, or they are not appropriate for use alongside other instruments in a survey of young children. The Quality of Life in School (QoLS) instrument is a short, self-report measure to assess elementary school students' perception of their quality of school life in four domains. The instrument was developed in Israel and has been validated among Hebrew-speaking children. The aim of the current study was to evaluate the psychometric properties of the QoLS measure in Canadian elementary school children. Methods. A total of 629 children attending grades 4-6 were recruited in a population-based cross-sectional study. The QoLS measure was administered to participating children by trained research assistants. In addition, their socio-demographic details and academic data were also obtained. The psychometric testing included exploratory factor analysis and reliability estimation using internal consistency (Cronbach's Alpha). Construct validity was investigated using the known groups comparisons for discriminative validity and via convergent validity. Results. A four-factor structure was generated explaining 39% of the total variance in the model. The results showed good internal consistency and acceptable floor and ceiling effects. Cronbach's Alpha ranged from 0.75 to 0.93. Known groups comparisons showed that the QoLS measure discriminated well between subgroups on the basis of gender, grade, and academic achievement, thus providing evidence of construct validity. The convergent validity was also appropriate with all the four domains demonstrating moderate to strong correlations to each other and to the total QoLS score. Conclusions. QoLS appears to be a valid and reliable measure for

  20. Introduction of a new instrument to measure motivation for gaming: the electronic gaming motives questionnaire.

    Science.gov (United States)

    Myrseth, Helga; Notelaers, Guy; Strand, Leif Åge; Borud, Einar Kristian; Olsen, Olav Kjellevold

    2017-09-01

    To adapt the four-dimensional Gambling Motives Questionnaire-Revised (GMQ-R) to measure the motivation for engaging in electronic gaming, and to validate the internal structure and investigate the criterion validity of the new Electronic Gaming Motives Questionnaire (EGMQ). The GMQ-R was adapted to measure motivation for playing video games and the new instrument was tested on a sample of Norwegian conscripts selected randomly from the pool of conscripts who started their military service between 2013 and 2015. The questionnaire was administered to all those who had played video games during the last 6 months and consisted of 853 gamers (86.8% men, mean age = 19.4 years). All participants completed the EGMQ, as well as other measures of gaming behaviour, gaming problems, boredom, loneliness and depression. The confirmatory factor analyses showed that the proposed EGMQ (measuring enhancement, coping, social and self-gratification motives) displayed satisfactory fit and internal consistency. Hierarchical regression analyses showed that gender emerged as a significant predictor (P motivational dimensions explained an additional 5.8-38.8% of the variance. Coping and self-gratification predicted gaming problems (P motivational dimensions were also predicted differentially by indicators of psychosocial wellbeing, indicating divergent validity of the four motives. The four-dimensional Electronic Gaming Motives Questionnaire is a valid instrument for measuring motives for gaming. © 2017 Society for the Study of Addiction.

  1. MITS instrumentation error analysis report

    International Nuclear Information System (INIS)

    Nelson, D.W.; Hillon, D.D.

    1980-01-01

    The MITS (Machine Interface Test System) installation consists of three types of process monitoring and control instrumentation: flow, pressure, and temperature. An effort has been made to assess the various instruments used and assign a value to the accuracy that can be expected. Efforts were also made to analyze the calibration and installation procedures to be used and determine how these might effect the system accuracy

  2. The influence of international and domestic events in the evolution of forest inventory and reporting consistency in the United States

    Science.gov (United States)

    W. Brad Smith

    2009-01-01

    This article takes a brief chronological look at resource inventory and reporting and links to international influences. It explores events as drivers of more consistent data within the United States and highlights key dates and events in the evolution of inventory policy and practice. From King George to L?Ecole nationale forestiere to the Food and Agriculture...

  3. Self-administered health literacy instruments for people with diabetes: systematic review of measurement properties.

    Science.gov (United States)

    Lee, Eun-Hyun; Kim, Chun-Ja; Lee, Jiyeon; Moon, Seung Hei

    2017-09-01

    The aims of this study were to identify all available self-administered instruments measuring health literacy in people with diabetes and to determine the current instrument that is the most appropriate for applying to this population in both practice and research. A systematic review of measurement properties. MEDLINE, EMBASE and CINAHL electronic databases from their inception up to 28 March 2016. The methodological quality of each included study was assessed using the COnsensus-based Standards for the selection of health Measurement INstruments checklist. The reported results for measurement properties in the studies were assessed according to Terwee's quality criteria. Thirteen self-administered instruments measuring health literacy in people with diabetes were identified, of which six (44%) were diabetes-specific instruments. The instruments that covered the broadest contents of health literacy were the Health Literacy Scale and Health Literacy Questionnaire. The (test-retest) reliability, measurement error and responsiveness were not evaluated for any instrument, while internal consistency and hypothesis testing validity were the most frequently assessed measurement properties. With the current evidence, the Health Literacy Scale may be the most appropriate instrument for patients with diabetes in practice and research. However, the structural validity of this scale needs to be further established, particularly in other language versions. It is also recommended to use the Diabetes Numeracy Test-15 along with the Health Literacy Scale to complement the lack of numeracy measures in the Health Literacy Scale. © 2017 John Wiley & Sons Ltd.

  4. Validity and reliability of the Turkish version of the pressure ulcer prevention knowledge assessment instrument.

    Science.gov (United States)

    Tulek, Zeliha; Polat, Cansu; Ozkan, Ilknur; Theofanidis, Dimitris; Togrol, Rifat Erdem

    2016-11-01

    Sound knowledge of pressure ulcers is important to enable good prevention. There are limited instruments assessing pressure ulcer knowledge. The Pressure Ulcer Prevention Knowledge Assessment Instrument is among the scales of which psychometric properties have been studied rigorously and reflects the latest evidence. This study aimed to evaluate the validity and reliability of the Turkish version of the Pressure Ulcer Prevention Knowledge Assessment Instrument (PUPKAI-T), an instrument that assesses knowledge of pressure ulcer prevention by using multiple-choice questions. Linguistic validity was verified through front-to-back translation. Psychometric properties of the instrument were studied on a sample of 150 nurses working in a tertiary hospital in Istanbul, Turkey. The content validity index of the translated instrument was 0.94, intra-class correlation coefficients were between 0.37 and 0.80, item difficulty indices were between 0.21 and 0.88, discrimination indices were 0.20-0.78, and the Kuder Richardson for the internal consistency was 0.803. The PUPKAI-T was found to be a valid and reliable tool to evaluate nurses' knowledge on pressure ulcer prevention. The PUPKAI-T may be a useful tool for determining educational needs of nurses on pressure ulcer prevention. Copyright © 2016 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  5. Assessment of test-retest reliability and internal consistency of the Wisconsin Gait Scale in hemiparetic post-stroke patients

    Directory of Open Access Journals (Sweden)

    Guzik Agnieszka

    2016-09-01

    Full Text Available Introduction: A proper assessment of gait pattern is a significant aspect in planning the process of teaching gait in hemiparetic post-stroke patients. The Wisconsin Gait Scale (WGS is an observational tool for assessing post-stroke patients’ gait. The aim of the study was to assess test-retest reliability and internal consistency of the WGS and examine correlations between gait assessment made with the WGS and gait speed, Brunnström scale, Ashworth’s scale and the Barthel Index.

  6. Novel mass spectrometric instrument for gaseous and particulate characterization and monitoring

    International Nuclear Information System (INIS)

    Coggiola, M.J.

    1994-02-01

    SRI International will develop a unique new instrument that will be capable of providing real-time (<1 minute), quantitative, chemical characterization of gaseous and particulate pollutants generated from DOE waste cleanup activities. The instrument will be capable of detecting and identifying volatile organic compounds, polynuclear aromatic hydrocarbons, heavy metals, and transuranic species released during waste cleanup activities. The instrument will be unique in its ability to detect and quantify in real-time these diverse pollutants in both vapor and particulate form. The instrument to be developed under this program will consist of several major components: (1) an isokinetic sampler capable of operating over a wide range of temperatures (up to 500 K) and flow rates; (2) a high pressure to low pressure transition and sampling region that efficiently separates particles from vapor-phase components for separate, parallel analyses; (3) two small mass spectrometers, one optimized for organic analysis using a unique field ionization source and one optimized for particulate characterization using thermal pyrolysis and electron-impact ionization (EI); and (4) a powerful personal computer for control and data acquisition. Initially, the instrument will be developed for targeted use in conjunction with the K-1435 Toxic Substances Control Act (TSCA) incinerator at the Oak Ridge National Laboratory K-25 site. Ultimately, the instrument will be designed to operate in the field at any cleanup site, located close to the stack or process vent, providing the plant operations personnel with real-time information and alarm capabilities. In addition, this instrument will be very broadly applicable for cleanup or sampling, for example, any time contaminated soil is moved or disturbed

  7. Cross-Cultural Adaptation of the Profile Fitness Mapping Neck Questionnaire to Brazilian Portuguese: Internal Consistency, Reliability, and Construct and Structural Validity.

    Science.gov (United States)

    Ferreira, Mariana Cândido; Björklund, Martin; Dach, Fabiola; Chaves, Thais Cristina

    The purpose of this study was to adapt and evaluate the psychometric properties of the ProFitMap-neck to Brazilian Portuguese. The cross-cultural adaptation consisted of 5 stages, and 180 female patients with chronic neck pain participated in the study. A subsample (n = 30) answered the pretest, and another subsample (n = 100) answered the questionnaire a second time. Internal consistency, test-retest reliability, and construct validity (hypothesis testing and structural validity) were estimated. For construct validity, the scores of the questionnaire were correlated with the Neck Disability Index (NDI), and the Hospital Anxiety and Depression Scale (HADS), the Tampa Scale of Kinesiophobia (TSK), and the 36-item Short-Form Health Survey (SF-36). Internal consistency was determined by adequate Cronbach's α values (α > 0.70). Strong reliability was identified by high intraclass correlation coefficients (ICC > 0.75). Construct validity was identified by moderate and strong correlations of the Br-ProFitMap-neck with total NDI score (-0.56 50%, Kaiser-Meyer-Olkin index > 0.50, eigenvalue > 1, and factor loadings > 0.2. Br-ProFitMap-neck had adequate psychometric properties and can be used in clinical settings, as well as research, in patients with chronic neck pain. Copyright © 2017. Published by Elsevier Inc.

  8. Development of an instrument to assess the health related quality of life of kidney stone formers.

    Science.gov (United States)

    Penniston, Kristina L; Nakada, Stephen Y

    2013-03-01

    Urolithiasis is associated with pain and other decreases in health related quality of life, yet there is no urolithiasis specific instrument to measure quality of life. Quality of life is an important end point in the management of urolithiasis. Therefore, we developed the Wisconsin StoneQOL, a disease specific instrument to assess the quality of life of patients with urolithiasis. Patients and urology providers identified important concepts related to quality of life of stone formers in groups and in individual cognitive interviews. Patients were recurrent stone formers including those with and those without current stones. A preliminary instrument was created, followed by patient feedback and item reduction. A 28-question instrument was ultimately developed which was tested for reliability as well as internal face, construct and discriminant validity in 248 stone formers. The internal consistency (for questions within domains) was high (mean Cronbach's α = 0.81). Correlation between domains was confirmed (Cronbach's α = 0.86). Discriminant validity was shown as stone formers with current stones scored lower than those who were stone-free. Among patients with active stones, those with symptoms scored lower on most questions and for the total score (p instrument that captures the unique symptoms and challenges associated with urolithiasis. As such, the Wisconsin StoneQOL is capable of assessing the health related quality of life of stone formers at various points along the disease continuum. Future assessment will establish minimal clinically important differences for use in individual patients. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  9. Psychometric Evaluation of an Instrument for Measuring Organizational Climate for Quality: Evidence From a National Sample of Infection Preventionists.

    Science.gov (United States)

    Pogorzelska-Maziarz, Monika; Nembhard, Ingrid M; Schnall, Rebecca; Nelson, Shanelle; Stone, Patricia W

    2016-09-01

    In recent years, there has been increased interest in measuring the climate for infection prevention; however, reliable and valid instruments are lacking. This study tested the psychometric properties of the Leading a Culture of Quality for Infection Prevention (LCQ-IP) instrument measuring the infection prevention climate in a sample of 972 infection preventionists from acute care hospitals. An exploratory principal component analysis showed that the instrument had structural validity and captured 4 factors related to the climate for infection prevention: Psychological Safety, Prioritization of Quality, Supportive Work Environment, and Improvement Orientation. LCQ-IP exhibited excellent internal consistency, with a Cronbach α of .926. Criterion validity was supported with overall LCQ-IP scores, increasing with the number of evidence-based prevention policies in place (P = .047). This psychometrically sound instrument may be helpful to researchers and providers in assessing climate for quality related to infection prevention. © The Author(s) 2015.

  10. Reconstruction of instrumentation and control system (SKR)

    International Nuclear Information System (INIS)

    Wiening, K.-H.

    2001-01-01

    For the first time extensive upgrades have been performed in all safety related areas of units with WWER 440/230 reactors. One of the most important actions was the replacement of the safety and safety related instrumentation and control. The state of the art digital safety instrumentation and control system TELEPERM XS has been implemented in units 1 and 2 of the Bohunice V1 power plant. The requirements as deduced from safety assessments conducted by commissions of international experts have been fulfilled, so that Bohunice V1 after this gradual reconstruction has been upgraded to an internationally accepted safety level for the remainder of its service life. (author)

  11. Redesigning current instruments as a precondition for a more effective environmental protection

    Directory of Open Access Journals (Sweden)

    Adžemović Mesud R.

    2017-01-01

    Full Text Available The problems of environment and evaluation of natural capital belong to the phenomenology of externalities, and the requirements of environmental economics are ever more oriented towards the elaboration of the ecological–economic category of the externalization of internal expenses, wherefrom reasons for the introduction of ecological–economic instruments, before all payments for pollutions, ensue. Demystification of the negative conviction relating ecological payments as taxes is very important, since it must be shown that ecological payments correct, mitigate or remove externalities. Environmental protection is a complex system and it consists in a set of rules, measures and instruments that are applied for the surveillance of pollution sources, and shaping of instruments for environmental protection is a complex process intended for the accomplishment of established ecological goals. Among all instruments available for bridging the gap of internalization and exerting a significant effect on polluters to diminish their emissions of pollution, the ecological and economic ones are most important. The results of our investigation have demonstrated that it is necessary to reshape the current set of instruments regarding protection of vital functions of nature and an efficient environmental protection, and one of the key cognitions is that the scientific and professional public must not be excluded from the appraisals of creating and redesigning the instruments of environmental protection. These assertions have their foundation in the premise that the significance of elements of the social dimension in sustainable development is to a great extent determined by the level of environmental degradation and reduction in capacity of renewable sources. The paper, approach and data processing of the conducted research offer a new model and new elements of methodology for establishing the state and quality of the environment, whereby social

  12. [The CAD-S, an instrument for the assessment of adaptation to divorce - separation].

    Science.gov (United States)

    Yárnoz Yaben, Sagrario; Comino González, Priscila

    2010-02-01

    The CAD-S, an Instrument for the Assessment of Adaptation to Divorce - Separation. This paper presents an instrument for the evaluation of the adaptation to divorce-separation. The CAD-S is a questionnaire created in Spanish, made up of 20 items whose aim is the evaluation of the family's adaptation to divorce-separation, using one of the parents as informant. Data were collected in four different samples of divorced persons and their children from different autonomous comunities from the Spanish state. 223 parents and 160 children from divorced families took part in this study. Four factors emerged, accounting for 52.39 percent of the total variance: psychological and emotional difficulties, conflict with the ex-partner, disposition to co-parentality, and negative outcomes of separation for children. The results suggest that CAD-S appears to be a reliable and valid instrument, with high internal consistency (Cronbach's alpha) and adequate construct validity supported by its relations with measures of satisfaction with life (SWLS), in the case of parents, and conduct problems (CBCL) for children.

  13. Thermophysical instruments for non-destructive examination of tightness and internal gas pressure or irradiated power reactor fuel rods

    International Nuclear Information System (INIS)

    Pastoushin, V.V.; Novikov, A.Yu.; Bibilashvili, Yu.K.

    1998-01-01

    The developed thermophysical method and technical instruments for non-destructive leak-tightness and gas pressure inspection inside irradiated power reactor fuel rods and FAs under poolside and hot cell conditions are described. The method of gas pressure measuring based on the examination of parameters of thermal convection that aroused in gas volume of rod plenum by special technical instruments. The developed method and technique allows accurate value determination of not only one of the main critical rod parameters, namely total internal gas pressure, that forms rod mean life in the reactor core, but also the partial pressure of every main constituent of gaseous mixture inside irradiated fuel rod, that provides the feasibility of authentic and reliable leak-tightness detection. The described techniques were experimentally checked during the examination of all types power reactor fuel rods existing in Russia (WWER, BN, RBMK) and could form the basis for new technique development for non-destructive examination of PWR (and other) type rods and FAs having gas plenum filled with spring or another elements of design. (author)

  14. Sixteen-item Anxiety Sensitivity Index: Confirmatory factor analytic evidence, internal consistency, and construct validity in a young adult sample from the Netherlands

    NARCIS (Netherlands)

    Vujanovic, Anka A.; Arrindell, Willem A.; Bernstein, Amit; Norton, Peter J.; Zvolensky, Michael J.

    The present investigation examined the factor structure, internal consistency, and construct validity of the 16-item Anxiety Sensitivity Index (ASI; Reiss Peterson, Gursky, & McNally 1986) in a young adult sample (n = 420)from the Netherlands. Confirmatory factor analysis was used to comparatively

  15. IAEA programme on maintenance of nuclear instruments

    International Nuclear Information System (INIS)

    Vuister, P.H.

    1986-01-01

    The Medical Applications Section in the Division of Life Sciences of the International Atomic Energy Agency has been engaged since 1975 in activities aimed at the more effective use of nuclear instruments. Activities and achievements are described concerning the conditioning of laboratories, preventive maintenance and repair of instruments, the management thereof, space parts and the promotion of local training in these subjects. (author)

  16. Proceedings of the Scientific Meeting in Nuclear Instrumentation Engineering

    International Nuclear Information System (INIS)

    Achmad Suntoro; Rony Djokorayono; Ferry Sujatno; Utaja

    2010-11-01

    The Proceeding of the Scientific Meeting in Nuclear Instrumentation Engineering held on Nov, 30, 2010 by the Centre for Nuclear Instrumentation Engineering - National Nuclear Energy Agency. The Proceedings of the Scientific Contains 40 papers Consist of Nuclear Instrumentation Engineering for Industry, Environment, and Nuclear Facilities. (PPIKSN)

  17. Robust Instrumentation[Water treatment for power plant]; Robust Instrumentering

    Energy Technology Data Exchange (ETDEWEB)

    Wik, Anders [Vattenfall Utveckling AB, Stockholm (Sweden)

    2003-08-01

    Cementa Slite Power Station is a heat recovery steam generator (HRSG) with moderate steam data; 3.0 MPa and 420 deg C. The heat is recovered from Cementa, a cement industry, without any usage of auxiliary fuel. The Power station commenced operation in 2001. The layout of the plant is unusual, there are no similar in Sweden and very few world-wide, so the operational experiences are limited. In connection with the commissioning of the power plant a R and D project was identified with the objective to minimise the manpower needed for chemistry management of the plant. The lean chemistry management is based on robust instrumentation and chemical-free water treatment plant. The concept with robust instrumentation consists of the following components; choice of on-line instrumentation with a minimum of O and M and a chemical-free water treatment. The parameters are specific conductivity, cation conductivity, oxygen and pH. In addition to that, two fairly new on-line instruments were included; corrosion monitors and differential pH calculated from specific and cation conductivity. The chemical-free water treatment plant consists of softening, reverse osmosis and electro-deionisation. The operational experience shows that the cycle chemistry is not within the guidelines due to major problems with the operation of the power plant. These problems have made it impossible to reach steady state and thereby not viable to fully verify and validate the concept with robust instrumentation. From readings on the panel of the online analysers some conclusions may be drawn, e.g. the differential pH measurements have fulfilled the expectations. The other on-line analysers have been working satisfactorily apart from contamination with turbine oil, which has been noticed at least twice. The corrosion monitors seem to be working but the lack of trend curves from the mainframe computer system makes it hard to draw any clear conclusions. The chemical-free water treatment has met all

  18. SSCL RFQ-DTL Matching Section instrumentation

    International Nuclear Information System (INIS)

    Datte, P.; Aielo, R.; Hayworth, M.

    1993-11-01

    A description of the SSCL RFQ-DTL Matching Section instrumentation is presented with emphasis on design issues and early instrumentation commissioning results. The H - beam energy through the RFQ-DTL matching section is 2.5 MeV, the beam current is 27 mA with a pulse width of 35 Its. The typical beam diameter is 3 mm. The instrumentation consists of three beam position monitors (BPM), a wire scanner, beam loss monitors (BLM), a slit and collector emittance measurement unit (EMU), a current toroid, and a Faraday cup. The instruments were designed to accommodate high current densities, have a large dynamic range with moderate bandwidths, and fit congested spaces

  19. Consistent guiding center drift theories

    International Nuclear Information System (INIS)

    Wimmel, H.K.

    1982-04-01

    Various guiding-center drift theories are presented that are optimized in respect of consistency. They satisfy exact energy conservation theorems (in time-independent fields), Liouville's theorems, and appropriate power balance equations. A theoretical framework is given that allows direct and exact derivation of associated drift-kinetic equations from the respective guiding-center drift-orbit theories. These drift-kinetic equations are listed. Northrop's non-optimized theory is discussed for reference, and internal consistency relations of G.C. drift theories are presented. (orig.)

  20. Validation of the International Index of Erectile Function (IIFE) for Use in Brazil

    International Nuclear Information System (INIS)

    Gonzáles, Ana Inês; Sties, Sabrina Weiss; Wittkopf, Priscilla Geraldine; Mara, Lourenço Sampaio de; Ulbrich, Anderson Zampier; Cardoso, Fernando Luiz; Carvalho, Tales de

    2013-01-01

    The International Index of Erectile Function has been proposed as a method for assessing sexual function assisting the diagnosis and classification of erectile dysfunction. However, IIEF was not validated for the Portuguese language. Validate the International Index of Erectile Function in patients with cardiopulmonary and metabolic diseases. The sample consisted of 108 participants of to Cardiopulmonary and Metabolic program Rehabilitation (CPMR) in southern Brazil. The clarity assessment of the instrument was performed using a scale ranging from zero to 10. The construct validity was carried out by confirmatory factor analysis (KMO = 0.85; Barllet p < 0.001), internal consistency by Cronbach's alpha and reproducibility and interrater reliability via the test retest method. The items were considered very clear with averages superior to 9. The internal consistency resulted in 0.89. The majority of items related correctly with their domains, with exception of three questions from sexual satisfaction domain, and one from erectile function. All items showed excellent stability of measure and substantial to almost perfect agreement. The present study showed that the IIEF is valid and reliable for use in participants of a cardiopulmonary and metabolic rehabilitation program

  1. Validation of the International Index of Erectile Function (IIFE) for Use in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Gonzáles, Ana Inês; Sties, Sabrina Weiss; Wittkopf, Priscilla Geraldine, E-mail: sabrinasties@yahoo.com.br; Mara, Lourenço Sampaio de; Ulbrich, Anderson Zampier; Cardoso, Fernando Luiz; Carvalho, Tales de [Universidade do Estado de Santa Catarina, Florianópolis, SC (Brazil)

    2013-08-15

    The International Index of Erectile Function has been proposed as a method for assessing sexual function assisting the diagnosis and classification of erectile dysfunction. However, IIEF was not validated for the Portuguese language. Validate the International Index of Erectile Function in patients with cardiopulmonary and metabolic diseases. The sample consisted of 108 participants of to Cardiopulmonary and Metabolic program Rehabilitation (CPMR) in southern Brazil. The clarity assessment of the instrument was performed using a scale ranging from zero to 10. The construct validity was carried out by confirmatory factor analysis (KMO = 0.85; Barllet p < 0.001), internal consistency by Cronbach's alpha and reproducibility and interrater reliability via the test retest method. The items were considered very clear with averages superior to 9. The internal consistency resulted in 0.89. The majority of items related correctly with their domains, with exception of three questions from sexual satisfaction domain, and one from erectile function. All items showed excellent stability of measure and substantial to almost perfect agreement. The present study showed that the IIEF is valid and reliable for use in participants of a cardiopulmonary and metabolic rehabilitation program.

  2. [An instrument in Spanish to evaluate the performance of clinical teachers by students].

    Science.gov (United States)

    Bitran, Marcela; Mena, Beltrán; Riquelme, Arnoldo; Padilla, Oslando; Sánchez, Ignacio; Moreno, Rodrigo

    2010-06-01

    The modernization of clinical teaching has called for the creation of faculty development programs, and the design of suitable instruments to evaluate clinical teachers' performance. To report the development and validation of an instrument in Spanish designed to measure the students' perceptions of their clinical teachers' performance and to provide them with feedback to improve their teaching practices. In a process that included the active participation of authorities, professors in charge of courses and internships, clinical teachers, students and medical education experts, we developed a 30-item questionnaire called MEDUC30 to evaluate the performance of clinical teachers by their students. The internal validity was assessed by factor analysis of 5214 evaluations of 265 teachers, gathered from 2004 to 2007. The reliability was measured with the Cronbach's alpha coefficient and the generalizability coefficient (g). MEDUC30 had good content and construct validity. Its internal structure was compatible with four factors: patient-centered teaching, teaching skills, assessment skills and learning climate, and it proved to be consistent with the structure anticipated by the theory. The scores were highly reliable (Cronbach's alpha: 0.97); five evaluations per teacher were sufficient to reach a reliability coefficient (g) of 0.8. MEDUC30 is a valid, reliable and useful instrument to evaluate the performance of clinical teachers. To our knowledge, this is the first instrument in Spanish for which solid validity and reliability evidences have been reported. We hope that MEDUC30 will be used to improve medical education in Spanish-speaking medical schools, providing teachers a specific feedback upon which to improve their pedagogical practice, and authorities with valuable information for the assessment of their faculty.

  3. Comparison of instrumented anterior interbody fusion with instrumented circumferential lumbar fusion.

    Science.gov (United States)

    Madan, S S; Boeree, N R

    2003-12-01

    Posterior lumbar interbody fusion (PLIF) restores disc height, the load bearing ability of anterior ligaments and muscles, root canal dimensions, and spinal balance. It immobilizes the painful degenerate spinal segment and decompresses the nerve roots. Anterior lumbar interbody fusion (ALIF) does the same, but could have complications of graft extrusion, compression and instability contributing to pseudarthrosis in the absence of instrumentation. The purpose of this study was to assess and compare the outcome of instrumented circumferential fusion through a posterior approach [PLIF and posterolateral fusion (PLF)] with instrumented ALIF using the Hartshill horseshoe cage, for comparable degrees of internal disc disruption and clinical disability. It was designed as a prospective study, comparing the outcome of two methods of instrumented interbody fusion for internal disc disruption. Between April 1994 and June 1998, the senior author (N.R.B.) performed 39 instrumented ALIF procedures and 35 instrumented circumferential fusion with PLIF procedures. The second author, an independent assessor (S.M.), performed the entire review. Preoperative radiographic assessment included plain radiographs, magnetic resonance imaging (MRI) and provocative discography in all the patients. The outcome in the two groups was compared in terms of radiological improvement and clinical improvement, measured on the basis of improvement of back pain and work capacity. Preoperatively, patients were asked to fill out a questionnaire giving their demographic details, maximum walking distance and current employment status in order to establish the comparability of the two groups. Patient assessment was with the Oswestry Disability Index, quality of life questionnaire (subjective), pain drawing, visual analogue scale, disability benefit, compensation status, and psychological profile. The results of the study showed a satisfactory outcome (scorelife questionnaire) score of 71.8% (28 patients) in

  4. Scenarios for the use of GHG-reduction instruments - how can policy-instruments as carbon emission trading and tradable green certificates be used simultaneously to reach a common GHG-reduction target?

    International Nuclear Information System (INIS)

    Morthorst, P.E.

    2000-01-01

    According to the agreed burden sharing in the EU, a number of member states have to reduce their emissions of greenhouse gases substantially. To achieve these reductions various policy-instruments - national as well as international - are on hand. Two international instruments are emphasized in this paper: tradable quotas for limiting carbon emissions and tradable green certificates for promoting the deployment of renewable energy technologies. In the analyses of these two instruments two main questions are considered: (1) Will there be any international trade in green certificates, if no GHG-credits are attached to them? (2) Will it make any difference if the EU sets the targets to be achieved by the two instruments or alternatively the individual member countries do? An incentive-analysis in which four scenarios are set up and discussed is performed for the EU member states. The main conclusion is that if no GHG-credits are attached to the green certificates there seems to be limited of no incentives for a permanent international trade in certificates. On the other hand, if GHG-credits are attached to the certificates an efficient international trade will take place regardless of whether the EU or the member countries fix the quotas. Thus, the use of international instruments as tradable green certificates and tradable emissions permits will not lead to an optimal GHG-reduction strategy unless GHG-credits are attached to the certificates. (author)

  5. Construction Of Critical Thinking Skills Test Instrument Related The Concept On Sound Wave

    Science.gov (United States)

    Mabruroh, F.; Suhandi, A.

    2017-02-01

    This study aimed to construct test instrument of critical thinking skills of high school students related the concept on sound wave. This research using a mixed methods with sequential exploratory design, consists of: 1) a preliminary study; 2) design and review of test instruments. The form of test instruments in essay questions, consist of 18 questions that was divided into 5 indicators and 8 sub-indicators of the critical thinking skills expressed by Ennis, with questions that are qualitative and contextual. Phases of preliminary study include: a) policy studies; b) survey to the school; c) and literature studies. Phases of the design and review of test instruments consist of two steps, namely a draft design of test instruments include: a) analysis of the depth of teaching materials; b) the selection of indicators and sub-indicators of critical thinking skills; c) analysis of indicators and sub-indicators of critical thinking skills; d) implementation of indicators and sub-indicators of critical thinking skills; and e) making the descriptions about the test instrument. In the next phase of the review test instruments, consist of: a) writing about the test instrument; b) validity test by experts; and c) revision of test instruments based on the validator.

  6. Alignment of Outcome Instruments Used in Hand Therapy With the Occupational Therapy Practice Framework: Domain and Process and the International Classification of Functioning, Disability and Health: A Scoping Review.

    Science.gov (United States)

    Lesher, Danielle Ann-Marie; Mulcahey, M J; Hershey, Peter; Stanton, Donna Breger; Tiedgen, Andrea C

    We sought to identify outcome instruments used in rehabilitation of the hand and upper extremity; to determine their alignment with the constructs of the International Classification of Functioning, Disability and Health (ICF) and the Occupational Therapy Practice Framework: Domain and Process; and to report gaps in the constructs measured by outcome instruments as a basis for future research. We searched CINAHL, MEDLINE, OTseeker, and the Cochrane Central Register of Controlled Trials using scoping review methodology and evaluated outcome instruments for concordance with the ICF and the Framework. We identified 18 outcome instruments for analysis. The findings pertain to occupational therapists' focus on body functions, body structures, client factors, and activities of daily living; a gap in practice patterns in use of instruments; and overestimation of the degree to which instruments used are occupationally based. Occupational therapy practitioners should use outcome instruments that embody conceptual frameworks for classifying function and activity. Copyright © 2017 by the American Occupational Therapy Association, Inc.

  7. Standardization of Nuclear Instrumentation Applied in the NPP and in other nuclear installations

    International Nuclear Information System (INIS)

    Kusnowo, Arlinah; Darmawati, Suzie

    2002-01-01

    Nuclear power plant (NPP) and other nuclear installations have been recognized as applications needing very sophisticated technologies. One of technologies used in this all nuclear facilities is nuclear instrumentation. In order that NPP and other nuclear installations be operated safely, nuclear instrumentation requires standardization from design to its operation. Internationally, standardizations of nuclear instrumentation have been issued by IEC (International Electrotechnical Commission). Formulation of standard in nuclear instrumentation in IEC is carried out by Technical Committee (TC) 45. This paper describes briefly the standardization of nuclear instrumentation applied in Indonesia as Indonesian National Standard (SNI, Standard National Indonesia), standardization of nuclear instrumentation developed by TC 45, SC 45A, and SC 45B, as well as the possibility to adopt and apply those IEC standard in Indonesia

  8. Evaluation of energy efficiency policy instruments effectiveness : case study Croatia

    International Nuclear Information System (INIS)

    Bukarica, V.

    2007-01-01

    This paper proposed a theoretical basis for evaluating energy efficiency policy in the Republic of Croatia and corroborated it with the analysis of energy efficiency market development and transformation. The current status of the market was evaluated and policy instruments were adapted to achieve optimal results. In particular, the energy efficiency market in Croatia was discussed in terms of micro and macro environment factors that influence policy making processes and the choice of policy instruments. The macro environment for energy efficiency market in Croatia is the process of European Union pre-integration with all related national and international legislation, political and economical factors and potential to use financial funds. The micro environment consists of government institutions, local financing institutions and a range of market players on the supply and demand side. Energy efficiency is the most powerful and cost-effective way for achieving goals of sustainable development. Policy instruments developed to improve energy efficiency are oriented towards a cleaner environment, better standard of living, more competitive industry and improved security of energy supply. Energy efficiency is much harder to implement and requires policy interventions. In response to recent trends in the energy sector, such as deregulation and open competition, policy measures aimed at improving energy efficiency should shift from an end-users oriented approach towards a whole market approach. The optimal policy instruments mix should be designed to meet defined targets. However, market dynamics must be taken into consideration. 9 refs., 4 figs

  9. Comment: Interactive Problem-Solving Interventions as Instrument of ...

    African Journals Online (AJOL)

    This structural and conceptual metamorphosis in the international conflict paradigm has required the international community to rethink the traditional and formal conflict management and third party intervention techniques and instruments such as negotiation and mediation. In the course of achieving these goals, conflict ...

  10. The nurses' self-concept instrument (NSCI): a comparison of domestic and international student nurses' professional self-concepts from a large Australian University.

    Science.gov (United States)

    Angel, Elizabeth; Craven, Rhonda; Denson, Nida

    2012-08-01

    Professional self-concept is a critical driver of job satisfaction. In Australia, as international nursing enrolments rise, nursing is increasingly characterised by a professional body of international nurses who may differ from domestic Australian nurses in their nursing self-concept. At present, little is known about the extent to which domestic and international students nurses' self-concepts may differ. The present study aimed to elucidate and contrast domestic and international nursing students' self-concepts from one large Australian university. A total of 253 domestic (n=218) and international (n=35) undergraduate nursing students from a large public university in Sydney, Australia completed the Nurses' Self-Concept Instrument (NSCI). Multiple-Indicator-Multiple-Indicator-Cause (MIMIC) modelling was used to assess the effects of student group (domestic and international) on the latent self-concept factors of the NSCI. Domestic and international students' professional self-concepts were similarly high. MIMIC modelling demonstrated that domestic students had a higher patient care self-concept in comparison to international students. Results imply that it may be useful for Australian universities to foster strategies that enhance specific domains of self-concepts (e.g., care) which may be underdeveloped for at least some cultural groups within the international nursing student population compared with domestic nursing students. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Análise da versão espanhola do Sport Satisfaction Instrument (SSI adaptado à Educação Física Analysis of the Spanish version of the Sport Satisfaction Instrument (SSI adapted to Physical Education

    Directory of Open Access Journals (Sweden)

    Antonio Granero-Gallegos

    2013-03-01

    Full Text Available O objetivo deste estudo foi analisar as propriedades psicométricas do Sport Satisfation Instrument (SSI adaptado para a Educação Física (EF por meio de uma análise fatorial exploratória da estrutura bidimensional do instrumento em uma amostra espanhola. Com isso, buscou-se determinar, de maneira preliminar, se o SSI constitui um instrumento válido e fiável para ser utilizado em futuras pesquisas. O instrumento foi elaborado em um modelo teórico de dois fatores: Satisfação/Diversão e Tédio. A amostra constituiu-se de um total de 224 alunos de secundária entre 12 e 19 anos. A versão [espanhola] do instrumento adaptado para a EF demonstrou níveis aceitáveis de consistência interna.The objective of this study was to analyze the psychometric properties of Sport Satisfaction Instrument (SSI adapted physical education (PE using exploratory factor analysis of the dimensional structure of the instrument in a Spanish sample. It was intended to determine, on a preliminary basis, whether it constitutes a valid and reliable for use in future research. Was administered to a total of 224 high school students 12 to 19 years. This analysis supports the hypothesized theoretical model of two factors (satisfaction / fun and boredom. The Spanish version of the instrument for PE showed acceptable levels of internal consistency.

  12. Inflammatory bowel disease-specific health-related quality of life instruments: a systematic review of measurement properties.

    Science.gov (United States)

    Chen, Xin-Lin; Zhong, Liang-Huan; Wen, Yi; Liu, Tian-Wen; Li, Xiao-Ying; Hou, Zheng-Kun; Hu, Yue; Mo, Chuan-Wei; Liu, Feng-Bin

    2017-09-15

    This review aims to critically appraise and compare the measurement properties of inflammatory bowel disease (IBD)-specific health-related quality of life instruments. Medline, EMBASE and ISI Web of Knowledge were searched from their inception to May 2016. IBD-specific instruments for patients with Crohn's disease, ulcerative colitis or IBD were enrolled. The basic characteristics and domains of the instruments were collected. The methodological quality of measurement properties and measurement properties of the instruments were assessed. Fifteen IBD-specific instruments were included, which included twelve instruments for adult IBD patients and three for paediatric IBD patients. All of the instruments were developed in North American and European countries. The following common domains were identified: IBD-related symptoms, physical, emotional and social domain. The methodological quality was satisfactory for content validity; fair in internal consistency, reliability, structural validity, hypotheses testing and criterion validity; and poor in measurement error, cross-cultural validity and responsiveness. For adult IBD patients, the IBDQ-32 and its short version (SIBDQ) had good measurement properties and were the most widely used worldwide. For paediatric IBD patients, the IMPACT-III had good measurement properties and had more translated versions. Most methodological quality should be promoted, especially measurement error, cross-cultural validity and responsiveness. The IBDQ-32 was the most widely used instrument with good reliability and validity, followed by the SIBDQ and IMPACT-III. Further validation studies are necessary to support the use of other instruments.

  13. Screening for frailty in elderly subjects living at home: validation of the Modified Short Emergency Geriatric Assessment (SEGAm) instrument.

    Science.gov (United States)

    Oubaya, N; Mahmoudi, R; Jolly, D; Zulfiqar, A A; Quignard, E; Cunin, C; Nazeyrollas, P; Novella, J L; Dramé, M

    2014-01-01

    To validate the modified version of the Short Emergency Geriatric Assessment (SEGAm) frailty instrument in elderly people living at home. Longitudinal, prospective, multicentre study. Four departments (Ardennes, Marne, Meurthe-et-Moselle, Meuse) in two French Regions (Champagne-Ardenne and Lorraine). Subjects aged 65 years or more, living at home, who could read and understand French, with a degree of autonomy corresponding to groups 5, or 6 in the AGGIR autonomy evaluation scale. Assessment included demographic characteristics, comprehensive geriatric assessment, and the SEGAm instrument. Psychometric validation was used to study feasibility and acceptability, internal structure validity, reliability, and discriminant validity of the SEGAm instrument. Between July 1st 2012 and March 31st 2013, 167 patients were included in the study. Averaged age was 77±7 years, the majority were women (70.7%). Feasibility and acceptability of the SEGAm instrument were excellent: we observed no refusal to participate, no drop-out during administration, no missing items, no ceiling or floor effects, and the administration time was short (5.0±3.5 min). By factor analysis, the instrument proved to be unidimensional. It showed good internal consistency (Cronbach's alpha coefficient: 0.68) and good test-retest (intra-class correlation: 0.88) at 7 days interval. Discriminant validity showed a significant difference, mainly for nutritional status, fall risk, dependency, mood and depression risk, and comorbidities. Based on these psychometric properties, the SEGAm appears to be an easy-to-use instrument that is particularly suitable for use in the community to identify frail elderly people who could benefit from early targeted interventions.

  14. [The Computer Book of the Internal Medicine resident: validity and reliability of a questionnaire for self-assessment of competences in internal medicine residents].

    Science.gov (United States)

    Oristrell, J; Casanovas, A; Jordana, R; Comet, R; Gil, M; Oliva, J C

    2012-12-01

    There are no simple and validated instruments for evaluating the training of specialists. To analyze the reliability and validity of a computerized self-assessment method to quantify the acquisition of medical competences during the Internal Medicine residency program. All residents of our department participated in the study during a period of 28 months. Twenty-two questionnaires specific for each rotation (the Computer-Book of the Internal Medicine Resident) were constructed with items (questions) corresponding to three competence domains: clinical skills competence, communication skills and teamwork. Reliability was analyzed by measuring the internal consistency of items in each competence domain using Cronbach's alpha index. Validation was performed by comparing mean scores in each competence domain between senior and junior residents. Cut-off levels of competence scores were established in order to identify the strengths and weaknesses of our training program. Finally, self-assessment values were correlated with the evaluations of the medical staff. There was a high internal consistency of the items of clinical skills competences, communication skills and teamwork. Higher scores of clinical skills competence and communication skills, but not in those of teamwork were observed in senior residents than in junior residents. The Computer-Book of the Internal Medicine Resident identified the strengths and weaknesses of our training program. We did not observe any correlation between the results of the self- evaluations and the evaluations made by staff physicians. The items of Computer-Book of the Internal Medicine Resident showed high internal consistency and made it possible to measure the acquisition of medical competences in a team of Internal Medicine residents. This self-assessment method should be complemented with other evaluation methods in order to assess the acquisition of medical competences by an individual resident. Copyright © 2012 Elsevier Espa

  15. Validation of an instrument to measure students' motivation and self-regulation towards technology learning

    Science.gov (United States)

    Liou, Pey-Yan; Kuo, Pei-Jung

    2014-05-01

    Background:Few studies have examined students' attitudinal perceptions of technology. There is no appropriate instrument to measure senior high school students' motivation and self-regulation toward technology learning among the current existing instruments in the field of technology education. Purpose:The present study is to validate an instrument for assessing senior high school students' motivation and self-regulation towards technology learning. Sample:A total of 1822 Taiwanese senior high school students (1020 males and 802 females) responded to the newly developed instrument. Design and method:The Motivation and Self-regulation towards Technology Learning (MSRTL) instrument was developed based on the previous instruments measuring students' motivation and self-regulation towards science learning. Exploratory and confirmatory factor analyses were utilized to investigate the structure of the items. Cronbach's alpha was applied for measuring the internal consistency of each scale. Furthermore, multivariate analysis of variance was used to examine gender differences. Results:Seven scales, including 'Technology learning self-efficacy,' 'Technology learning value,' 'Technology active learning strategies,' 'Technology learning environment stimulation,' 'Technology learning goal-orientation,' 'Technology learning self-regulation-triggering,' and 'Technology learning self-regulation-implementing' were confirmed for the MSRTL instrument. Moreover, the results also showed that male and female students did not present the same degree of preference in all of the scales. Conclusions:The MSRTL instrument composed of seven scales corresponding to 39 items was shown to be valid based on validity and reliability analyses. While male students tended to express more positive and active performance in the motivation scales, no gender differences were found in the self-regulation scales.

  16. The knowledge, efficacy, and practices instrument for oral health providers: a validity study with dental students.

    Science.gov (United States)

    Behar-Horenstein, Linda S; Garvan, Cyndi W; Moore, Thomas E; Catalanotto, Frank A

    2013-08-01

    Valid and reliable instruments to measure and assess cultural competence for oral health care providers are scarce in the literature, and most published scales have been contested due to a lack of item analysis and internal estimates of reliability. The purposes of this study were, first, to develop a standardized instrument to measure dental students' knowledge of diversity, skills in culturally competent patient-centered communication, and use of culture-centered practices in patient care and, second, to provide preliminary validity support for this instrument. The initial instrument used in this study was a thirty-six-item Likert-scale survey entitled the Knowledge, Efficacy, and Practices Instrument for Oral Health Providers (KEPI-OHP). This instrument is an adaption of an initially thirty-three-item version of the Multicultural Awareness, Knowledge, and Skills Scale-Counselor Edition (MAKSS-CE), a scale that assesses factors related to social justice, cultural differences among clients, and cross-cultural client management. After the authors conducted cognitive and expert interviews, focus groups, pilot testing, and item analysis, their initial instrument was reduced to twenty-eight items. The KEPI-OHP was then distributed to 916 dental students (response rate=48.6 percent) across the United States to measure its reliability and assess its validity. Both exploratory and confirmatory factor analyses were conducted to test the scale's validity. The modification of the survey into a sensible instrument with a relatively clear factor structure using factor analysis resulted in twenty items. A scree test suggested three expressive factors, which were retained for rotation. Bentler's comparative fit and Bentler and Bonnett's non-normed indices were 0.95 and 0.92, respectively. A three-factor solution, including efficacy of assessment, knowledge of diversity, and culture-centered practice subscales, comprised of twenty-items was identified. The KEPI-OHP was found to

  17. QNOTE: an instrument for measuring the quality of EHR clinical notes.

    Science.gov (United States)

    Burke, Harry B; Hoang, Albert; Becher, Dorothy; Fontelo, Paul; Liu, Fang; Stephens, Mark; Pangaro, Louis N; Sessums, Laura L; O'Malley, Patrick; Baxi, Nancy S; Bunt, Christopher W; Capaldi, Vincent F; Chen, Julie M; Cooper, Barbara A; Djuric, David A; Hodge, Joshua A; Kane, Shawn; Magee, Charles; Makary, Zizette R; Mallory, Renee M; Miller, Thomas; Saperstein, Adam; Servey, Jessica; Gimbel, Ronald W

    2014-01-01

    The outpatient clinical note documents the clinician's information collection, problem assessment, and patient management, yet there is currently no validated instrument to measure the quality of the electronic clinical note. This study evaluated the validity of the QNOTE instrument, which assesses 12 elements in the clinical note, for measuring the quality of clinical notes. It also compared its performance with a global instrument that assesses the clinical note as a whole. Retrospective multicenter blinded study of the clinical notes of 100 outpatients with type 2 diabetes mellitus who had been seen in clinic on at least three occasions. The 300 notes were rated by eight general internal medicine and eight family medicine practicing physicians. The QNOTE instrument scored the quality of the note as the sum of a set of 12 note element scores, and its inter-rater agreement was measured by the intraclass correlation coefficient. The Global instrument scored the note in its entirety, and its inter-rater agreement was measured by the Fleiss κ. The overall QNOTE inter-rater agreement was 0.82 (CI 0.80 to 0.84), and its note quality score was 65 (CI 64 to 66). The Global inter-rater agreement was 0.24 (CI 0.19 to 0.29), and its note quality score was 52 (CI 49 to 55). The QNOTE quality scores were consistent, and the overall QNOTE score was significantly higher than the overall Global score (p=0.04). We found the QNOTE to be a valid instrument for evaluating the quality of electronic clinical notes, and its performance was superior to that of the Global instrument. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Spanish adaptation of the internal functioning of the Work Teams Scale (QFI-22).

    Science.gov (United States)

    Ficapal-Cusí, Pilar; Boada-Grau, Joan; Torrent-Sellens, Joan; Vigil-Colet, Andreu

    2014-05-01

    The aim of this article is to develop the Spanish adaptation of the internal functioning of Work Teams Scale (QFI-22). The scale was adapted from the French version, and was applied to a sample of 1,055 employees working for firms operating in Spain. The article analyses the internal structure (exploratory and confirmatory factor analysis) and internal consistency, and provides convergent validity evidence of the scale. The QFI-22 scale shows the same internal structure as the original. Factor analysis confirmed the existence of two factors: interpersonal support and team work management, with good internal consistency coefficients (α1 = .93, α2 = .92). Regarding validity evidence, the QFI-22 scale has significant correlations with other correlates and alternative scales used for comparison purposes. The two factors correlated positively with team vision, participation safety, task orientation and support for innovation (Team Climate Inventory, TCI scale), with progressive culture (Organisational Culture, X-Y scale), and with creating change, customer focus and organisational learning (Denison Organizational Culture Survey, DOCS scale). In contrast, the two factors correlated negatively with traditional culture (X-Y scale). The QFI-22 scale is a useful instrument for assessing the internal functioning of work teams.

  19. JUDGMENT OF EXPERTS FOR THE VALIDATION OF AN INSTRUMENT OF MEASUREMENT OF BURNOUT SYNDROME IN TEACHING

    Directory of Open Access Journals (Sweden)

    Judith Araceli Dorantes-Nova

    2016-07-01

    Full Text Available Recent studies are proof of the importance of burnout syndrome, considered as one of the "occupational disease" worldwide. International organizations have been given the task of investigating the triggers and psychosocial involvement of workers in their working environment, however, among all sectors that have been analyzed, in teaching there is still a gap, this study, which purpose is to validate, by expert judgment, the contents of a diagnostic instrument of burnout syndrome in the current context of teachers, the factors involved in the detection of this disease are explored, taking as main reference features Maslach Burnout Inventory (MBI, but with a higher level of analysis and strength in Mexican stage. It validates the agreement and consistency of the items that assess levels of job satisfaction, product of organizational climate of the school, as factors affecting the appearance of burnout syndrome. The concordance coefficient W Kendall is used to measure the degree of correlation and internal consistency of variables among experts.

  20. MODEL EVALUASI INTERNAL KOMPETENSI GURU BAHASA INGGRIS (MODEL_EIKGBI SMA

    Directory of Open Access Journals (Sweden)

    Sahraini Sahraini

    2015-10-01

    Full Text Available Studi ini bertujuan untuk: (1 mengembangkan model evaluasi kompetensi guru bahasa Inggris SMA yang dapat digunakan untuk mengidentifikasi kelebihan dan kekurangan guru dalam proses pemelajaran dan (2 mengetahui efektivitas implementasi evaluasi internal kompetensi guru bahasa Inggris SMA. Studi ini menggunakan metode penelitian dan pengembangan yang dikembangkan oleh Borg & Gall (1983, p.775. Subjek penelitian berjumlah 17 guru yang berasal dari 7 SMA di Sulawesi Selatan. Konstruk instrumen terdiri atas instrumen untuk mengevaluasi kompetensi guru bahasa Inggris dalam merencanakan pemelajaran, instrumen untuk mengevaluasi kompetensi guru dalam melaksanaan proses pemelajaran, dan instrumen untuk mengevaluai kompetensi guru dalam mengevaluasi hasil proses pemelajaran. Hasil penelitian menunjukkan bahwa instrumen yang dikembangkan dapat digunakan untuk mengevaluasi kompetensi guru bahasa Inggris. Untuk mengetahui sejauh mana tingkat efektivitas Model Evaluasi Internal Kompetensi Guru Bahasa Inggris SMA, model ini kemudian dievaluasi oleh teman sejawat guru bahasa Inggris dan guru bahasa Inggris itu sendiri. Mereka menyimpulkan bahwa komponen dari model tersebut adalah komprehensip, praktis, ekonomis, dan telah didukung oleh instrumen yang valid dan reliabel. Kata kunci: evaluasi internal, model evaluasi, kompetensi guru   INTERNAL EVALUATION MODEL OF ENGLISH TEACHERS’ COMPETENCY (IEMET FOR SENIOR HIGH SCHOOL Abstract High School that can be used to identify the teacher’s strengths and weaknesses in learning and teaching processes and (2 find out the implementation effectiveness of the Internal Evaluation Model of English Teachers’ Competency for Senior High School. This study used research & development methods by following the pattern of phases developed by Borg & Gall (1983, p.775.  The subjects of this study were seventeen English teachers from seven Senior High Schools in South Sulawesi. The constructs of instruments consist of the

  1. Consistent force fields for saccharides

    DEFF Research Database (Denmark)

    Rasmussen, Kjeld

    1999-01-01

    Consistent force fields for carbohydrates were hitherto developed by extensive optimization ofpotential energy function parameters on experimental data and on ab initio results. A wide range of experimental data is used: internal structures obtained from gas phase electron diffraction and from x......-anomeric effects are accounted for without addition of specific terms. The work is done in the framework of the Consistent Force Field which originatedin Israel and was further developed in Denmark. The actual methods and strategies employed havebeen described previously. Extensive testing of the force field...

  2. Assessment of the measurement properties of the post stroke motor function instruments available in Brazil: a systematic review.

    Science.gov (United States)

    Lima, Elaine; Teixeira-Salmela, Luci F; Simões, Luan; Guerra, Ana C C; Lemos, Andrea

    2016-03-15

    While there are several instruments in Brazil that measure motor function in patients after stroke, it is unknown whether the measurement properties of these instruments are appropriate. To identify the motor function instruments available in Brazil for patients after stroke. To assess the methodological quality of the studies and the results related to the measurement properties of these instruments. Two independent reviewers conducted searches on PubMed, LILACS, CINAHL, Web of Science, and Scopus. Studies that aimed to cross-culturally adapt an existing instrument or create a Brazilian instrument and test at least one measurement property related to motor function in patients after stroke were included. The methodological quality of these studies was checked by the COSMIN checklist with 4-point rating scale and the results of the measurement properties were analyzed by the criteria developed by Terwee et al. A total of 11 instruments were considered eligible, none of which were created in Brazil. The process of cross-cultural adaptation was inadequate in 10 out of 11 instruments due to the lack of back-translation or due to inappropriate target population. All of the instruments presented flaws in the measurement properties, especially reliability, internal consistency, and construct validity. The flaws observed in both cross-cultural adaptation process and testing measurement properties make the results inconclusive on the validity of the available instruments. Adequate procedures of cross-cultural adaptation and measurement properties of these instruments are strongly needed.

  3. Assessment of the measurement properties of the post stroke motor function instruments available in Brazil: a systematic review

    Directory of Open Access Journals (Sweden)

    Elaine Lima

    2016-01-01

    Full Text Available Background While there are several instruments in Brazil that measure motor function in patients after stroke, it is unknown whether the measurement properties of these instruments are appropriate. Objective To identify the motor function instruments available in Brazil for patients after stroke. To assess the methodological quality of the studies and the results related to the measurement properties of these instruments. Method Two independent reviewers conducted searches on PubMed, LILACS, CINAHL, Web of Science, and Scopus. Studies that aimed to cross-culturally adapt an existing instrument or create a Brazilian instrument and test at least one measurement property related to motor function in patients after stroke were included. The methodological quality of these studies was checked by the COSMIN checklist with 4-point rating scale and the results of the measurement properties were analyzed by the criteria developed by Terwee et al. Results A total of 11 instruments were considered eligible, none of which were created in Brazil. The process of cross-cultural adaptation was inadequate in 10 out of 11 instruments due to the lack of back-translation or due to inappropriate target population. All of the instruments presented flaws in the measurement properties, especially reliability, internal consistency, and construct validity. Conclusion The flaws observed in both cross-cultural adaptation process and testing measurement properties make the results inconclusive on the validity of the available instruments. Adequate procedures of cross-cultural adaptation and measurement properties of these instruments are strongly needed.

  4. Safeguards instrumentation: past, present, future

    International Nuclear Information System (INIS)

    Higinbotham, W.A.

    1982-01-01

    Instruments are essential for accounting, for surveillance and for protection of nuclear materials. The development and application of such instrumentation is reviewed, with special attention to international safeguards applications. Active and passive nondestructive assay techniques are some 25 years of age. The important advances have been in learning how to use them effectively for specific applications, accompanied by major advances in radiation detectors, electronics, and, more recently, in mini-computers. The progress in seals has been disappointingly slow. Surveillance cameras have been widely used for many applications other than safeguards. The revolution in TV technology will have important implications. More sophisticated containment/surveillance equipment is being developed but has yet to be exploited. On the basis of this history, some expectations for instrumentation in the near future are presented

  5. Evidence for the Psychometric Validity, Internal Consistency and Measurement Invariance of Warwick Edinburgh Mental Well-being Scale Scores in Scottish and Irish Adolescents.

    Science.gov (United States)

    McKay, Michael T; Andretta, James R

    2017-09-01

    Mental well-being is an important indicator of current, but also the future health of adolescents. The 14-item Warwick Edinburgh Mental Well-being Scale (WEMWBS) has been well validated in adults world-wide, but less work has been undertaken to examine the psychometric validity and internal consistency of WEMWBS scores in adolescents. In particular, little research has examined scores on the short 7-item version of the WEMWBS. The present study used two large samples of school children in Scotland and Northern Ireland and found that for both forms of the WEMWBS, scores were psychometrically valid, internally consistent, factor saturated, and measurement invariant by country. Using the WEMWBS full form, males reported significantly higher scores than females, and Northern Irish adolescents reported significantly higher scores than their Scottish counterparts. Last, the lowest overall levels of well-being were observed among Scottish females. Copyright © 2017. Published by Elsevier B.V.

  6. Development of an instrument to measure health center (HC) personnel's computer use, knowledge and functionality demand for HC computerized information system in Thailand.

    Science.gov (United States)

    Kijsanayotin, Boonchai; Pannarunothai, Supasit; Speedie, Stuart

    2005-01-01

    Knowledge about socio-technical aspects of information technology (IT) is vital for the success of health IT projects. The Thailand health administration anticipates using health IT to support the recently implemented national universal health care system. However, the national knowledge associate with the socio-technical aspects of health IT has not been studied in Thailand. A survey instrument measuring Thai health center (HC) personnel's computer use, basic IT knowledge and HC computerized information system functionality needs was developed. The instrument reveals acceptable test-retest reliability and reasonable internal consistency of the measures. The future nation-wide demonstration study will benefit from this study.

  7. Geographic determination of the growing origins of Jamaican and international coffee using instrumental neutron activation analysis and other methods

    International Nuclear Information System (INIS)

    Antoine, J.M.R.; Hoo Fung, L.A.; Grant, Ch.N.

    2016-01-01

    This study was undertaken to determine whether elemental analysis could distinguish the growing origins of Jamaican versus international coffee and identify intra-island growing regions. Twenty-four samples of roasted and ground coffee and soluble coffee were collected and analysed using instrumental neutron activation analysis and inductively coupled plasma optical emission spectroscopy. Sixteen elements were selected for statistical evaluation. Soluble clustered discretely from roasted and ground samples. The distinction among roasted and ground samples was not as discrete. Geographic growing regions could be determined by statistical analysis; separating the growing sub-regions in Jamaica would require additional analyses. (author)

  8. A framework and a measurement instrument for sustainability of work practices in long-term care

    Directory of Open Access Journals (Sweden)

    Slaghuis Sarah S

    2011-11-01

    Full Text Available Abstract Background In health care, many organizations are working on quality improvement and/or innovation of their care practices. Although the effectiveness of improvement processes has been studied extensively, little attention has been given to sustainability of the changed work practices after implementation. The objective of this study is to develop a theoretical framework and measurement instrument for sustainability. To this end sustainability is conceptualized with two dimensions: routinization and institutionalization. Methods The exploratory methodological design consisted of three phases: a framework development; b instrument development; and c field testing in former improvement teams in a quality improvement program for health care (N teams = 63, N individual = 112. Data were collected not until at least one year had passed after implementation. Underlying constructs and their interrelations were explored using Structural Equation Modeling and Principal Component Analyses. Internal consistency was computed with Cronbach's alpha coefficient. A long and a short version of the instrument are proposed. Results The χ2- difference test of the -2 Log Likelihood estimates demonstrated that the hierarchical two factor model with routinization and institutionalization as separate constructs showed a better fit than the one factor model (p Conclusions The theoretical framework offers a valuable starting point for the analysis of sustainability on the level of actual changed work practices. Even though the two dimensions routinization and institutionalization are related, they are clearly distinguishable and each has distinct value in the discussion of sustainability. Finally, the subscales conformed to psychometric properties defined in literature. The instrument can be used in the evaluation of improvement projects.

  9. The PROactive instruments to measure physical activity in patients with chronic obstructive pulmonary disease

    Science.gov (United States)

    Gimeno-Santos, Elena; Raste, Yogini; Demeyer, Heleen; Louvaris, Zafeiris; de Jong, Corina; Rabinovich, Roberto A.; Hopkinson, Nicholas S.; Polkey, Michael I.; Vogiatzis, Ioannis; Tabberer, Maggie; Dobbels, Fabienne; Ivanoff, Nathalie; de Boer, Willem I.; van der Molen, Thys; Kulich, Karoly; Serra, Ignasi; Basagaña, Xavier; Troosters, Thierry; Puhan, Milo A.; Karlsson, Niklas

    2015-01-01

    No current patient-centred instrument captures all dimensions of physical activity in chronic obstructive pulmonary disease (COPD). Our objective was item reduction and initial validation of two instruments to measure physical activity in COPD. Physical activity was assessed in a 6-week, randomised, two-way cross-over, multicentre study using PROactive draft questionnaires (daily and clinical visit versions) and two activity monitors. Item reduction followed an iterative process including classical and Rasch model analyses, and input from patients and clinical experts. 236 COPD patients from five European centres were included. Results indicated the concept of physical activity in COPD had two domains, labelled “amount” and “difficulty”. After item reduction, the daily PROactive instrument comprised nine items and the clinical visit contained 14. Both demonstrated good model fit (person separation index >0.7). Confirmatory factor analysis supported the bidimensional structure. Both instruments had good internal consistency (Cronbach's α>0.8), test–retest reliability (intraclass correlation coefficient ≥0.9) and exhibited moderate-to-high correlations (r>0.6) with related constructs and very low correlations (r<0.3) with unrelated constructs, providing evidence for construct validity. Daily and clinical visit “PROactive physical activity in COPD” instruments are hybrid tools combining a short patient-reported outcome questionnaire and two activity monitor variables which provide simple, valid and reliable measures of physical activity in COPD patients. PMID:26022965

  10. Cross-cultural adaptation of the korean version of the minneapolis-manchester quality of life instrument-adolescent form.

    Science.gov (United States)

    Park, Hyeon Jin; Yang, Hyung Kook; Shin, Dong Wook; Kim, Yoon Yi; Kim, Young Ae; Yun, Young Ho; Nam, Byung Ho; Bhatia, Smita; Park, Byung Kiu; Ghim, Thad T; Kang, Hyoung Jin; Park, Kyung Duk; Shin, Hee Young; Ahn, Hyo Seop

    2013-12-01

    We verified the reliability and validity of the Korean version of the Minneapolis-Manchester Quality of Life Instrument-Adolescent Form (KMMQL-AF) among Korean childhood cancer survivors. A total of 107 childhood cancer patients undergoing cancer treatment and 98 childhood cancer survivors who completed cancer treatment were recruited. To assess the internal structure of the KMMQL-AF, we performed multi-trait scaling analyses and exploratory factor analysis. Additionally, we compared each domains of the KMMQL-AF with those of the Karnofsky Performance Status Scale and the Revised Children's Manifest Anxiety Scale (RCMAS). Internal consistency of the KMMQL-AF was sufficient (Cronbach's alpha: 0.78-0.92). In multi-trait scaling analyses, the KMMQL-AF showed sufficient construct validity. The "physical functioning" domain showed moderate correlation with Karnofsky scores and the "psychological functioning" domain showed moderate-to-high correlation with the RCMAS. The KMMQL-AF discriminated between subgroups of different adolescent cancer survivors depending on treatment completion. The KMMQL-AF is a sufficiently reliable and valid instrument for measuring quality of life among Korean childhood cancer survivors.

  11. International Energy Agency instrumented facilities survey for solar assisted low energy dwellings

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-02-01

    Compiled are surveys outlining the instrumentation of 38 active and passive solar projects in 9 countries (Denmark, Italy, Japan, Netherlands, Sweden, Switzerland, United Kingdom, United States, and West Germany). After the surveys themselves are presented, the data are rearranged to compare answers from similar survey questions for each of the projects. These questions address building, solar system and instrumentation descriptions and meteorological, solar system and building system instrumentatation capabilities. (LEW)

  12. Development of an instrument to measure patient perception of the quality of nursing care and related hospital services at the national hospital of sri lanka.

    Science.gov (United States)

    Senarat, Upul; Gunawardena, Nalika S

    2011-06-01

    This study aimed to develop and validate an instrument to measure patient perception of quality of nursing care and related hospital services in a tertiary care setting. We compiled an instrument with 72 items that patients may perceive as quality of nursing care and related hospital services, following an extensive literature search, discussions with patients and care pro-I viders and a brainstorming session with an expert panel. A cross-sectional study was conducted at the National Hospital of Sri Lanka. A sample (n = 120) of patients stayed in general surgical or medical units responded to the interviewer administered instrument upon discharge. Item analysis and principal component factor analysis were performed to assess validity, and internal consistency was calculated to measure reliability. Of the 72 items, 18 had greater than 20% of responses as 'not relevant'. A further 11 items were eliminated since item-total correlations were less than .2. Factor analysis was performed on remaining 43 items which resulted in 36 items classifying into eight factors accounting for 71% of the variation. Factor loadings in the final solution after Varimax rotation were interpersonal aspects (.68-.85), efficiency (.62-.79), competency (.66-.68), comfort (.60-.84), physical environment (.65-.82), cleanliness (.81-.85), personalized information (.76-.83), and general instructions (.61-.78). The instrument had high Internal consistency (Cronbach's alpha = .91). We developed a comprehensive, reliable and valid, 36-item instrument that may be used to measure patient perception of quality of nursing care in tertiary care settings. Copyright © 2011 Korean Society of Nursing Science. Published by Elsevier B.V. All rights reserved.

  13. A systematic review of instruments that measure attitudes toward homosexual men.

    Science.gov (United States)

    Grey, Jeremy A; Robinson, Beatrice Bean E; Coleman, Eli; Bockting, Walter O

    2013-01-01

    Scientific interest in the measurement of homophobia and internalized homophobia has grown over the past 30 years, and new instruments and terms have emerged. To help researchers with the challenging task of identifying appropriate measures for studies in sexual-minority health, we reviewed measures of homophobia published in the academic literature from 1970 to 2012. Instruments that measured attitudes toward male homosexuals/homosexuality or measured homosexuals' internalized attitudes toward homosexuality were identified using measurement manuals and a systematic review. A total of 23 instruments met criteria for inclusion, and their features were summarized and compared. All 23 instruments met minimal criteria for adequate scale construction, including scale development, sampling, reliability, and evidence of validity. Validity evidence was diverse and was categorized as interaction with gay men, HIV/AIDS variables, mental health, and conservative religious or political beliefs. Homophobia was additionally correlated with authoritarianism and bias, gender ideology, gender differences, and reactions to homosexual stimuli. Internalized homophobia was validated by examining relationships with disclosing one's homosexuality and level of homosexual identity development. We hope this review will make the process of instrument selection more efficient by allowing researchers to easily locate, evaluate, and choose the proper measure based on their research question and population of interest.

  14. Development and Psychometric Assessment of the Healthcare Provider Cultural Competence Instrument

    Directory of Open Access Journals (Sweden)

    Joshua L. Schwarz PhD

    2015-04-01

    Full Text Available This study presents the measurement properties of 5 scales used in the Healthcare Provider Cultural Competence Instrument (HPCCI. The HPCCI measures a health care provider’s cultural competence along 5 primary dimensions: (1 awareness/sensitivity, (2 behaviors, (3 patient-centered communication, (4 practice orientation, and (5 self-assessment. Exploratory factor analysis demonstrated that the 5 scales were distinct, and within each scale items loaded as expected. Reliability statistics indicated a high level of internal consistency within each scale. The results indicate that the HPCCI effectively measures the cultural competence of health care providers and can provide useful professional feedback for practitioners and organizations seeking to increase a practitioner’s cultural competence.

  15. Developing and evaluating an instrument to measure Recovery After INtensive care: the RAIN instrument.

    Science.gov (United States)

    Bergbom, Ingegerd; Karlsson, Veronika; Ringdal, Mona

    2018-01-01

    Measuring and evaluating patients' recovery, following intensive care, is essential for assessing their recovery process. By using a questionnaire, which includes spiritual and existential aspects, possibilities for identifying appropriate nursing care activities may be facilitated. The study describes the development and evaluation of a recovery questionnaire and its validity and reliability. A questionnaire consisting of 30 items on a 5-point Likert scale was completed by 169 patients (103 men, 66 women), 18 years or older (m=69, SD 12.5) at 2, 6, 12 or 24 months following discharge from an ICU. An exploratory factor analysis, including a principal component analysis with orthogonal varimax rotation, was conducted. Ten initial items, with loadings below 0.40, were removed. The internal item/scale structure obtained in the principal component analysis was tested in relation to convergent and discrimination validity with a multi-trait analysis. Items consistency and reliability were assessed by Cronbach's alpha and internal item consistency. Test of scale quality, the proportion of missing values and respondents' scoring at maximum and minimum levels were also conducted. A total of 20 items in six factors - forward looking, supporting relations, existential ruminations, revaluation of life, physical and mental strength and need of social support were extracted with eigen values above one. Together, they explained 75% of the variance. The half-scale criterion showed that the proportion of incomplete scale scores ranged from 0% to 4.3%. When testing the scale's ability to differentiate between levels of the assessed concept, we found that the observed range of scale scores covered the theoretical range. Substantial proportions of respondents, who scored at the ceiling for forward looking and supporting relations and at floor for the need of social support, were found. These findings should be further investigated. The factor analysis, including discriminant validity

  16. Second international tsunami workshop on the technical aspects of tsunami warning systems, tsunami analysis, preparedness, observation and instrumentation

    International Nuclear Information System (INIS)

    1989-01-01

    The Second Workshop on the Technical Aspects of Tsunami Warning Systems, Tsunami Analysis, Preparedness, Observation, and Instrumentation, sponsored and convened by the Intergovernmental Oceanographic Commission (IOC), was held on 1-2 August 1989, in the modern and attractive research town of Academgorodok, which is located 20 km south from downtown Novosibirsk, the capital of Siberia, USSR. The Program was arranged in eight major areas of interest covering the following: Opening and Introduction; Survey of Existing Tsunami Warning Centers - present status, results of work, plans for future development; Survey of some existing seismic data processing systems and future projects; Methods for fast evaluation of Tsunami potential and perspectives of their implementation; Tsunami data bases; Tsunami instrumentation and observations; Tsunami preparedness; and finally, a general discussion and adoption of recommendations. The Workshop presentations not only addressed the conceptual improvements that have been made, but focused on the inner workings of the Tsunami Warning System, as well, including computer applications, on-line processing and numerical modelling. Furthermore, presentations reported on progress has been made in the last few years on data telemetry, instrumentation and communications. Emphasis was placed on new concepts and their application into operational techniques that can result in improvements in data collection, rapid processing of the data, in analysis and prediction. A Summary Report on the Second International Tsunami Workshop, containing abstracted and annotated proceedings has been published as a separate report. The present Report is a Supplement to the Summary Report and contains the full text of the papers presented at this Workshop. Refs, figs and tabs

  17. Mixed-realism simulation of adverse event disclosure: an educational methodology and assessment instrument.

    Science.gov (United States)

    Matos, Francisco M; Raemer, Daniel B

    2013-04-01

    Physicians have an ethical duty to disclose adverse events to patients or families. Various strategies have been reported for teaching disclosure, but no instruments have been shown to be reliable for assessing them.The aims of this study were to report a structured method for teaching adverse event disclosure using mixed-realism simulation, develop and begin to validate an instrument for assessing performance, and describe the disclosure practice of anesthesiology trainees. Forty-two anesthesiology trainees participated in a 2-part exercise with mixed-realism simulation. The first part took place using a mannequin patient in a simulated operating room where trainees became enmeshed in a clinical episode that led to an adverse event and the second part in a simulated postoperative care unit where the learner is asked to disclose to a standardized patient who systematically moves through epochs of grief response. Two raters scored subjects using an assessment instrument we developed that combines a 4-element behaviorally anchored rating scale (BARS) and a 5-stage objective rating scale. The performance scores for elements within the BARS and the 5-stage instrument showed excellent interrater reliability (Cohen's κ = 0.7), appropriate range (mean range for BARS, 4.20-4.47; mean range for 5-stage instrument, 3.73-4.46), and high internal consistency (P realism simulation that engages learners in an adverse event and allows them to practice disclosure to a structured range of patient responses. We have developed a reliable 2-part instrument with strong psychometric properties for assessing disclosure performance.

  18. The learning environment of paediatric interns in South Africa.

    Science.gov (United States)

    Naidoo, Kimesh L; Van Wyk, Jacqueline M; Adhikari, Miriam

    2017-11-29

    South African (SA) paediatric interns (recently qualified medical graduates) work in a high disease burdened and resource deficient environment for two years, prior to independent practice. Perceptions of this learning environment (LE) influences their approaches to training as well as the outcomes of this period of development. Obstacles to creating a supportive LE and supervisor interaction affects the quality of this training. Measuring perceptions of the LE with validated instruments can help inform improvements in learning during this crucial period of medical education. The aims of this study was to determine the psychometric qualities of the Postgraduate Hospital Educational Environment Measure (PHEEM) amongst paediatric interns across four hospital complexes in South Africa and to measure the LE as perceived by both interns and their supervisors. Construct validity was tested using factor analysis and internal consistency was measured with Cronbach's alpha. A total of 209 interns and 60 supervisors (69% intern response rate) responded to the questionnaire. The PHEEM was found to be very reliable with an overall Cronbach's alpha of 0.943 and 0.874 for intern and supervisors respectively. Factor analysis using a 3-factor solution accounted for 42% of the variance with the teaching subscale having the best fit compared with the other sub-scales of the original tool. Most interns perceived the learning environment as being more positive than negative however, their perceptions differed significantly from that of their supervisors. Poor infrastructural support from institutions, excessive workloads and inadequate supervision were factors preventing optimal training of paediatric interns. The SA version of the PHEEM tool used was found to be a reliable and valid instrument for use in interns amongst high disease burdened contexts. Various obstacles to creating an ideal learning environment for paediatric interns were identified to be in need of urgent review. Key

  19. Instrument evaluation no. 16. Nuclear enterprises portable doserate meter type PDR4 and external probes types BP1/1, BP8 and GP9

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1979-08-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This report presents the evaluation of Nuclear Enterprises Portable Doserate Meter Type PDR4 and External Probes Types BP1/1, BP8 and GP9

  20. Transcultural adaptation to Spanish of the instrument "Effectiveness of Auditory Rehabilitation" for the assessment of quality of life in patients using hearing aids.

    Science.gov (United States)

    Cardemil, Felipe; Esquivel, Patricia; Aguayo, Lorena; Barría, Tamara; Fuente, Adrian; Carvajal, Rocío; Fromín, Rose; Villalobos, Iván; Yueh, Bevan

    2013-01-01

    It is becoming increasingly important to have reliable and valid questionnaires. This becomes especially important when evaluating hearing loss. the "Effectiveness of Auditory Rehabilitation" (EAR) questionnaire for the Spanish-speaking population. This instrument assesses quality of life and hearing aspects in patients using hearing aids. Cross-sectional validation study. A cultural adaptation through the use of English to Spanish translations and re-translations was carried out. The validity and reliability of the newly adapted instrument were evaluated. A total of 69 individuals (44 older adults and 25 younger adults) were examined. The pure-tone averages (PTA, 500, 1,000 and 2,000 Hz) were 47.3 dB HL and 47.1 dB HL for the left and right ears, respectively. The mean maximum speech discrimination in silence for monosyllables were 83.3% and 82.9% for the left and right ears, respectively. Internal consistency presented Cronbach alpha values of 0.85 and 0.77 for the internal and external dimensions, respectively. The intraclass correlation coefficients were 0.80 for the internal module and 0.85 for the external module. Construct validity reported a correlation coefficient of 0.71 at baseline and 0.76 at 3 months after the initial assessment for the internal module, and 0.62 at baseline and 0.74 at 3 months after the initial assessment for the external module. The size effects were 1.3 and 1.1 for the internal and external modules, respectively. The Spanish version of the EAR questionnaire seems to be a reliable and valid instrument. The evaluation of audiological aspects, as well as aspects relating to aesthetics and comfort are the main strengths of this instrument. Finally, the EAR scale is more sensitive to change than other scales. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  1. A dynamic Thurstonian item response theory of motive expression in the picture story exercise: solving the internal consistency paradox of the PSE.

    Science.gov (United States)

    Lang, Jonas W B

    2014-07-01

    The measurement of implicit or unconscious motives using the picture story exercise (PSE) has long been a target of debate in the psychological literature. Most debates have centered on the apparent paradox that PSE measures of implicit motives typically show low internal consistency reliability on common indices like Cronbach's alpha but nevertheless predict behavioral outcomes. I describe a dynamic Thurstonian item response theory (IRT) model that builds on dynamic system theories of motivation, theorizing on the PSE response process, and recent advancements in Thurstonian IRT modeling of choice data. To assess the models' capability to explain the internal consistency paradox, I first fitted the model to archival data (Gurin, Veroff, & Feld, 1957) and then simulated data based on bias-corrected model estimates from the real data. Simulation results revealed that the average squared correlation reliability for the motives in the Thurstonian IRT model was .74 and that Cronbach's alpha values were similar to the real data (value of extant evidence from motivational research using PSE motive measures. (c) 2014 APA, all rights reserved.

  2. The Iranian version of 12-item Short Form Health Survey (SF-12: factor structure, internal consistency and construct validity

    Directory of Open Access Journals (Sweden)

    Mousavi Sayed

    2009-09-01

    Full Text Available Abstract Background The 12-item Short Form Health Survey (SF-12 as a shorter alternative of the SF-36 is largely used in health outcomes surveys. The aim of this study was to validate the SF-12 in Iran. Methods A random sample of the general population aged 15 years and over living in Tehran, Iran completed the SF-12. Reliability was estimated using internal consistency and validity was assessed using known groups comparison and convergent validity. In addition, the factor structure of the questionnaire was extracted by performing both exploratory factor analysis (EFA and confirmatory factor analysis (CFA. Results: In all, 5587 individuals were studied (2721 male and 2866 female. The mean age and formal education of the respondents were 35.1 (SD = 15.4 and 10.2 (SD = 4.4 years respectively. The results showed satisfactory internal consistency for both summary measures, that are the Physical Component Summary (PCS and the Mental Component Summary (MCS; Cronbach's α for PCS-12 and MCS-12 was 0.73 and 0.72, respectively. Known-groups comparison showed that the SF-12 discriminated well between men and women and those who differed in age and educational status (P Conclusion In general the findings suggest that the SF-12 is a reliable and valid measure of health related quality of life among Iranian population. However, further studies are needed to establish stronger psychometric properties for this alternative form of the SF-36 Health Survey in Iran.

  3. TROPOMI and TROPI: UV/VIS/NIR/SWIR instruments

    NARCIS (Netherlands)

    Levelt, P.F.; Oord, G.H.J. van den; Dobber, M.; Eskes, H.; Weele, M. van; Veefkind, P.; Oss, R. van; Aben, I.; Jongma, R.T.; Landgraf, J.; Vries, J. de; Visser, H.

    2006-01-01

    TROPOMI (Tropospheric Ozone-Monitoring Instrument) is a five-channel UV-VIS-NIR-SWIR non-scanning nadir viewing imaging spectrometer that combines a wide swath (114°) with high spatial resolution (10 × 10 km 2). The instrument heritage consists of GOME on ERS-2, SCIAMACHY on Envisat and, especially,

  4. Cross- cultural validation of the Brazilian Portuguese version of the Social Phobia Inventory (SPIN: study of the items and internal consistency Validação transcultural da versão para o português do Brasil do Social Phobia Inventory (SPIN: estudo dos itens e da consistência interna

    Directory of Open Access Journals (Sweden)

    Flávia de Lima Osório

    2009-03-01

    Full Text Available OBJECTIVE: The objective of the present study was to carry out the cross- cultural validation for Brazilian Portuguese of the Social Phobia Inventory, an instrument for the evaluation of fear, avoidance and physiological symptoms associated with social anxiety disorder. METHOD: The process of translation and adaptation involved four bilingual professionals, appreciation and approval of the back- translation by the authors of the original scale, a pilot study with 30 Brazilian university students, and appreciation by raters who confirmed the face validity of the Portuguese version, which was named " Inventário de Fobia Social" . As part of the psychometric study of the Social Phobia Inventory, analysis of the items and evaluation of the internal consistency of the instrument were performed in a study conducted on 2314 university students. RESULTS: The results demonstrated that item 11, related to the fear of public speaking, was the most frequently scored item. The correlation of the items with the total score was quite adequate, ranging from 0.44 to 0.71, as was the internal consistency, which ranged from 0.71 to 0.90. DISCUSSION/CONCLUSION: The authors conclude that the Brazilian Portuguese version of the Social Phobia Inventory proved to be adequate regarding the psychometric properties initially studied, with qualities quite close to those of the original study. Studies that will evaluate the remaining indicators of validity of the Social Phobia Inventory in clinical and non-clinical samples are considered to be opportune and necessary.OBJETIVO: O objetivo deste estudo foi realizar a validação transcultural para o português do Brasil do Social Phobia Inventory, um instrumento para avaliação e mensuração dos sintomas de medo, evitação e sintomas fisiológicos associados ao transtorno de ansiedade social. MÉTODO: O processo de tradução e adaptação envolveu quatro profissionais bilingües, apreciação e aprovação da back

  5. Solution assay instrument operations manual

    International Nuclear Information System (INIS)

    Li, T.K.; Marks, T.; Parker, J.L.

    1983-09-01

    An at-line solution assay instrument (SAI) has been developed and installed in a plutonium purification and americium recovery process area in the Los Alamos Plutonium Processing Facility. The instrument was designed for accurate, timely, and simultaneous nondestructive analysis of plutonium and americium in process solutions that have a wide range of concentrations and americium/plutonium ratios and for routine operation by process technicians who lack instrumentation background. The SAI, based on transmission-corrected, high-resolution gamma-ray spectroscopy, has two measurement stations attached to a single multichannel analyzer/computer system. To ensure the quality of assay results, the SAI has an internal measurement control program, which requires daily and weekly check runs and monitors key aspects of all assay runs. For a 25-ml sample, the assay precision is 5 g/l within a 2000-s count time

  6. 26 CFR 1.338-8 - Asset and stock consistency.

    Science.gov (United States)

    2010-04-01

    ... that are controlled foreign corporations. (6) Stock consistency. This section limits the application of... 26 Internal Revenue 4 2010-04-01 2010-04-01 false Asset and stock consistency. 1.338-8 Section 1... (CONTINUED) INCOME TAXES Effects on Corporation § 1.338-8 Asset and stock consistency. (a) Introduction—(1...

  7. The WHO Tobacco Convention: A New Dawn in the Implementation of International Health Instrument? Comment on "The Legal Strength of International Health Instruments - What It Brings to Global Health Governance?"

    Science.gov (United States)

    Durojaye, Ebenezer

    2017-07-05

    The Tobacco Convention was adopted by the World Health Organization (WHO) in 2003. Nikogosian and Kickbusch examine the five potential impacts of the Tobacco Convention and its Protocol on public health. These include the adoption of the Convention would seem to unlock the treaty-making powers of WHO; the impact of the Convention in the global health architecture has been phenomenal globally; the Convention has facilitated the adoption of further instruments to strengthen its implementation at the national level; the Convention has led to the adoption of appropriate legal framework to combat the use of tobacco at the national level and that the impact of the Convention would seem to go beyond public health but has also led to the adoption of the Protocol to Eliminate Illicit Trade in Tobacco. However, the article by Nikogosian and Kickbusch would seem to overlook some of the challenges that may militate against the effective implementation of international law, including the Tobacco Convention, at the national level. © 2018 The Author(s); Published by Kerman University of Medical Sciences. This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  8. International energy financing

    International Nuclear Information System (INIS)

    Vedavalli, Rangaswamy

    1994-01-01

    Some of the innovative financing options being considered by developing countries and economies in transition as ways of mobilizing international energy financing are discussed. Build-Own-Operate (BOO) and Transfer (BOOT) is the most commonly adopted approach. This involves limited resource financing of a project on the basis of the associated cash flow and risks and not on the credit of the project owners. The World Bank has set up the Multilateral Investment Guarantee Agency to provide, on a fee basis, guarantees against certain non-commercial forms of risk in order to promote international capital flow to developing countries. In 1989, the World Bank introduced the Expanded Co-financing Operations (ECO) programme as an instrument to catalyze the flow of private finance into developing countries and to improve their access to international financial markets. Other financial instruments currently being established include: leasing of equipment or whole plants by foreign investors; private ownership or operation of generation and distribution facilities; exchange of specific export goods for energy imports; developing instruments to finance local costs; revenue bonds; tax-exempt bonds; sale of electricity futures to those seeking more stable, longer term electricity price contracts. (UK)

  9. A guide on instrument of biochemistry and molecular biology

    International Nuclear Information System (INIS)

    1995-10-01

    This book is about instrument on biochemistry and molecular biology, which consists of six chapters. It deals with introduction of advanced bio-instrument, common utilization and maintain, explanation of each instrument like capillary electrophoresis, interactive laser cytometer, personal computer and software, an electron microscope and DNA/RNS synthesis instrument, large equipment and special system like information system and network, analysis system for genome and large spectro graph, outside donation, examples for common utilization and appendix on data like application form for use.

  10. Borehole instrument for scintillation gamma spectrometer

    International Nuclear Information System (INIS)

    Sinitsyn, A.Ya.; Gabitov, R.M.

    1979-01-01

    Described are a schematic diagram and main specifications of a borehole instrument with autostabilization of energy scale measure by gamma bench-mark of 137 Cs, intended for the application in a logging gamma spectrometer to determine separately the concentrations of nature radioactive elements. The instrument may be connected to the KOBDFM-2 cable of 600 m length. It contains a scintillation counter for gamma quanta consisting of 30x70 mm NaI(Tl) crystal and a FEU-85 photoamplifier, an input conforming stage, a diagram of threshold pulse formation and regulating high-voltage generator. The borehole instrument has been proved under laboratory and field conditions at 10-40 deg C

  11. Research on Web-Based Networked Virtual Instrument System

    International Nuclear Information System (INIS)

    Tang, B P; Xu, C; He, Q Y; Lu, D

    2006-01-01

    The web-based networked virtual instrument (NVI) system is designed by using the object oriented methodology (OOM). The architecture of the NVI system consists of two major parts: client-web server interaction and instrument server-virtual instrument (VI) communication. The web server communicates with the instrument server and the clients connected to it over the Internet, and it handles identifying the user's name, managing the connection between the user and the instrument server, adding, removing and configuring VI's information. The instrument server handles setting the parameters of VI, confirming the condition of VI and saving the VI's condition information into the database. The NVI system is required to be a general-purpose measurement system that is easy to maintain, adapt and extend. Virtual instruments are connected to the instrument server and clients can remotely configure and operate these virtual instruments. An application of The NVI system is given in the end of the paper

  12. Career-success scale - a new instrument to assess young physicians' academic career steps.

    Science.gov (United States)

    Buddeberg-Fischer, Barbara; Stamm, Martina; Buddeberg, Claus; Klaghofer, Richard

    2008-06-02

    Within the framework of a prospective cohort study of Swiss medical school graduates, a Career-Success Scale (CSS) was constructed in a sample of young physicians choosing different career paths in medicine. Furthermore the influence of personality factors, the participants' personal situation, and career related factors on their career success was investigated. 406 residents were assessed in terms of career aspired to, and their career progress. The Career-Success Scale, consisting of 7 items, was developed and validated, addressing objective criteria of academic career advancement. The influence of gender and career aspiration was investigated by a two-factorial analysis of variance, the relationships between personality factors, personal situation, career related factors and the Career-Success Scale by a multivariate linear regression analysis. The unidimensional Career-Success Scale has an internal consistency of 0.76. It is significantly correlated at the bivariate level with gender, instrumentality, and all career related factors, particularly with academic career and received mentoring. In multiple regression, only gender, academic career, surgery as chosen specialty, and received mentoring are significant predictors. The highest values were observed in participants aspiring to an academic career, followed by those pursuing a hospital career and those wanting to run a private practice. Independent of the career aspired to, female residents have lower scores than their male colleagues. The Career-Success Scale proved to be a short, reliable and valid instrument to measure career achievements. As mentoring is an independent predictor of career success, mentoring programs could be an important instrument to specifically enhance careers of female physicians in academia.

  13. Measuring medical students' attitudes and knowledge about geriatrics and gerontology in Brazilian medical students: A comparison of instruments.

    Science.gov (United States)

    Lucchetti, Alessandra Lg; da S Ezequiel, Oscarina; Moreira-Almeida, Alexander; Lucchetti, Giancarlo

    2018-04-14

    To compare instruments available for evaluating attitudes and knowledge about geriatrics and gerontology. This cross-sectional study investigated 83 third-year Brazilian medical students (with exposure to geriatrics and gerontology) and 75 incoming students (with no exposure to this content). We used the University of California at Los Angeles Geriatrics Attitudes Scale, Palmore's Facts on Aging Quiz, modified Maxwell-Sullivan Attitude Survey, Aging Semantic Differential Scale and an instrument assessing their cognitive knowledge in geriatrics. The instruments investigated had moderate-to-high correlations when evaluating similar constructs, had satisfactory or borderline internal consistency for the most part (Cronbach's α: 0.62-0.94) and were capable of discriminating between students exposed or not to practical and theoretical content. Our findings reinforce previous studies that these scales are capable of differentiating students who have or have not had exposure/intervention and, in general, seem to be assessing different constructs. © 2018 AJA Inc.

  14. Tenth meeting of the International Working Group on Nuclear Power Plant Control and Instrumentation, Vienna, 3-5 March 1986

    International Nuclear Information System (INIS)

    1986-07-01

    The meeting of the International Working Group on Nuclear Power Plant Control and Instrumentation (IWG-NPPCI) was organized in order to summarize operating experience of NPP control systems, gain a general overview of activities in development of modern control systems and receive recommendations on the further directions and particular measures within the Agency's programme. The papers and discussions mostly dealt with practical experience and described actual problems encountered. Emphasis was placed on the technical, industrial and economic aspects of the introduction of modern, highly automated control systems and on the improvement of plant availability and safety. A separate abstract was prepared for each of the 20 presentations of the meeting

  15. Instrumentation for PSD based neutron diffractometers at Dhruva reactor

    International Nuclear Information System (INIS)

    Pande, S.S.; Borkar, S.P.; Prafulla, S.; Srivastava, V.D.; Behare, A.; Mukhopadhyay, P.K.; Ghodgaonkar, M.D.; Kataria, S.K.

    2004-01-01

    Linear position sensitive detectors (PSDs) are widely used to configure neutron diffractometers and other instruments. Necessary front-end electronics and a data acquisition system is developed to cater to such instruments built around the Dhruva research reactor in BARC. These include three diffractometers with multiple PSDs and four with single PSD. The front-end electronics consists of high voltage units, preamplifiers, shaping amplifiers, ratio ADCs (RDC). The data acquisition system consists of an interface card and software. Commercially available hardware like temperature controller or stepper motor controller connected over GPIB or RS232 are also integrated in the data acquisition system. The data acquisition is automated so that it can continue unattended for control parameter like temperature, thus enabling optimum utilization of available beam time. The instrumentation is scalable and can be easily configured for various instrumental requirements. The front-end electronics and the data acquisition system are described here. (author)

  16. Instruments to assess patients with rotator cuff pathology: a systematic review of measurement properties.

    Science.gov (United States)

    Longo, Umile Giuseppe; Saris, Daniël; Poolman, Rudolf W; Berton, Alessandra; Denaro, Vincenzo

    2012-10-01

    The aims of this study were to obtain an overview of the methodological quality of studies on the measurement properties of rotator cuff questionnaires and to describe how well various aspects of the design and statistical analyses of studies on measurement properties are performed. A systematic review of published studies on the measurement properties of rotator cuff questionnaires was performed. Two investigators independently rated the quality of the studies using the Consensus-based Standards for the selection of health Measurement Instruments checklist. This checklist was developed in an international Delphi consensus study. Sixteen studies were included, in which two measurement instruments were evaluated, namely the Western Ontario Rotator Cuff Index and the Rotator Cuff Quality-of-Life Measure. The methodological quality of the included studies was adequate on some properties (construct validity, reliability, responsiveness, internal consistency, and translation) but need to be improved on other aspects. The most important methodological aspects that need to be developed are as follows: measurement error, content validity, structural validity, cross-cultural validity, criterion validity, and interpretability. Considering the importance of adequate measurement properties, it is concluded that, in the field of rotator cuff pathology, there is room for improvement in the methodological quality of studies measurement properties. II.

  17. The DUNDRUM Quartet: validation of structured professional judgement instruments DUNDRUM-3 assessment of programme completion and DUNDRUM-4 assessment of recovery in forensic mental health services.

    LENUS (Irish Health Repository)

    O'Dwyer, Sarah

    2011-07-03

    Abstract Background Moving a forensic mental health patient from one level of therapeutic security to a lower level or to the community is influenced by more than risk assessment and risk management. We set out to construct and validate structured professional judgement instruments for consistency and transparency in decision making Methods Two instruments were developed, the seven-item DUNDRUM-3 programme completion instrument and the six item DUNDRUM-4 recovery instrument. These were assessed for all 95 forensic patients at Ireland\\'s only forensic mental health hospital. Results The two instruments had good internal consistency (Cronbach\\'s alpha 0.911 and 0.887). Scores distinguished those allowed no leave or accompanied leave from those with unaccompanied leave (ANOVA F = 38.1 and 50.3 respectively, p < 0.001). Scores also distinguished those in acute\\/high security units from those in medium or in low secure\\/pre-discharge units. Each individual item distinguished these levels of need significantly. The DUNDRUM-3 and DUNDRUM-4 correlated moderately with measures of dynamic risk and with the CANFOR staff rated unmet need (Spearman r = 0.5, p < 0.001). Conclusions The DUNDRUM-3 programme completion items distinguished significantly between levels of therapeutic security while the DUNDRUM-4 recovery items consistently distinguished those given unaccompanied leave outside the hospital and those in the lowest levels of therapeutic security. This data forms the basis for a prospective study of outcomes now underway.

  18. Assessing the quality of decision support technologies using the International Patient Decision Aid Standards instrument (IPDASi.

    Directory of Open Access Journals (Sweden)

    Glyn Elwyn

    Full Text Available To describe the development, validation and inter-rater reliability of an instrument to measure the quality of patient decision support technologies (decision aids.Scale development study, involving construct, item and scale development, validation and reliability testing.There has been increasing use of decision support technologies--adjuncts to the discussions clinicians have with patients about difficult decisions. A global interest in developing these interventions exists among both for-profit and not-for-profit organisations. It is therefore essential to have internationally accepted standards to assess the quality of their development, process, content, potential bias and method of field testing and evaluation.Scale development study, involving construct, item and scale development, validation and reliability testing.Twenty-five researcher-members of the International Patient Decision Aid Standards Collaboration worked together to develop the instrument (IPDASi. In the fourth Stage (reliability study, eight raters assessed thirty randomly selected decision support technologies.IPDASi measures quality in 10 dimensions, using 47 items, and provides an overall quality score (scaled from 0 to 100 for each intervention. Overall IPDASi scores ranged from 33 to 82 across the decision support technologies sampled (n = 30, enabling discrimination. The inter-rater intraclass correlation for the overall quality score was 0.80. Correlations of dimension scores with the overall score were all positive (0.31 to 0.68. Cronbach's alpha values for the 8 raters ranged from 0.72 to 0.93. Cronbach's alphas based on the dimension means ranged from 0.50 to 0.81, indicating that the dimensions, although well correlated, measure different aspects of decision support technology quality. A short version (19 items was also developed that had very similar mean scores to IPDASi and high correlation between short score and overall score 0.87 (CI 0.79 to 0.92.This work

  19. Present problems of standardization in nuclear instrumentation in Romania

    International Nuclear Information System (INIS)

    Purghel, Lidia

    2001-01-01

    The continuos development of nuclear techniques, based on international cooperation, led to the need for producing national and international standards referring to terminology, classification, technical characteristic, testing and calibration methods for nuclear instrumentation. The international standardization activity is organised in the frame of the well-known organization like IEC, ISO, ICRU, ICRP, IOLM, CENELEC, EFOMP, WHO. High advances were obtained in the standardization of the ionising radiation dosimetry in the frame of the International Commission for Radiation Units (ICRU) which started its works 1925. Romania is member of the International Electrotechnical Commission (IEC) from 1920 when its president was the formal member of Romanian Academy, professor Remus Radulet. Romania is effectively involved in standardization activities in the field nuclear instrumentation both as user and manufacturer of nuclear instrumentation. At national level the Technical Committee 45, as a branch of the Romanian Electrotechnical Committee is hosted by Horia Hulubei National Institute for Physics and Nuclear Engineering. The technical committee has the tasks of analysing the market, the regulations and the industry requirements and proposing new standards or revision for existing one. A table is given showing the number of IEC standards considered by TC 45, adopted RS - IEC standards (prepared/published) and planned for 2000/2001. Romania hosted IEC international plenary meetings in 1962 and 1974 and an IEC workshop 1997 with participation of specialists from USA, Sweden, Germany, France, Japan and Romania. As industry is striving to use more and more standard products, that means best quality and safety for less money, more than ever one have to convince the industry about the usefulness and specificity of the nuclear standards

  20. D-Zero Superconducting Soleniod RTD Instrumentation Readings Upon Receipt at Fermilab

    International Nuclear Information System (INIS)

    Markley, D.

    1998-01-01

    This engineering note documents the Dzero Superconducting Solenoid Platinum RTD, Carbon Glass RTD, and Helium level gage instrumentation values upon receipt at Fermilab. This note is concerned with the internal instrumentation, the external instrumentation can easily be repaired if any problems arise. The Solenoid was Purchased from Toshiba and shipped from the Kehin Works in Japan. The Solenoid was received at Dzero May 12, 1997. The Solenoid was shipped in three large components. They are the Solenoid, Control Dewar, and Chimney. There are 2 main instrumentation port areas where all the internal instrumentation is available to the outside world. These 2 places are the top of the Control Dewar and the North end of the Solenoid. These two instrumentation feedthrough area's have Cyocera hermetic feedthrough port connectors welded into place. The Cyocera connector can and does mate with the Burndy Bantom cable end connector of the same pin/socket number. Since the Hermetic feedthrough and cable connector are different manufacturers, the pin layout pattern is not the same. The Toshiba drawings show both manufacturers pin numbers. The Dzero engineering notes show only the Burndy pin numbers.

  1. ICFA Instrumentation Bulletin, Volume 22, Spring 2001 Issue (SLAC-J-ICFA-022)

    Energy Technology Data Exchange (ETDEWEB)

    Va' Vra, J.

    2003-10-21

    The publication of the ICFA Instrumentation Bulletin is an activity of the Panel on Future Innovation and Development of ICFA (International Committee for Future Accelerators). The Bulletin reports on research and progress in the field of instrumentation with emphasis on application in the field of high-energy physics. It encourages issues of generic instrumentation. This volume contains the following articles: (1) ''Gaseous Micropattern Detectors: High-Energy Physics and Beyond''; (2) ''DIRC Dreams Redux: Research Directions for the Next Generation of Internally Reflected Imaging Counters''; and (3) ''Corrosion of Glass Windows in DIRC PMTs''.

  2. Holdup Measures on an SRNL Mossbauer Spectroscopy Instrument

    Energy Technology Data Exchange (ETDEWEB)

    Dewberry, R.; Brown, T.; Salaymeh, S.

    2010-05-05

    Gamma-ray holdup measurements of a Mossbauer spectroscopy instrument are described and modeled. In the qualitative acquisitions obtained in a low background area of Savannah River National Laboratory, only Am-241 and Np-237 activity were observed. The Am-241 was known to be the instrumental activation source, while the Np-237 is clearly observed as a source of contamination internal to the instrument. The two sources of activity are modeled separately in two acquisition configurations using two separate modeling tools. The results agree well, demonstrating a content of (1980 {+-} 150) {mu}Ci Am-241 and (110 {+-} 50) {mu}Ci of Np-237.

  3. Measuring determinants of career satisfaction of anesthesiologists: validation of a survey instrument.

    Science.gov (United States)

    Afonso, Anoushka M; Diaz, James H; Scher, Corey S; Beyl, Robbie A; Nair, Singh R; Kaye, Alan David

    2013-06-01

    To measure the parameter of job satisfaction among anesthesiologists. Survey instrument. Academic anesthesiology departments in the United States. 320 anesthesiologists who attended the annual meeting of the ASA in 2009 (95% response rate). The anonymous 50-item survey collected information on 26 independent demographic variables and 24 dependent ranked variables of career satisfaction among practicing anesthesiologists. Mean survey scores were calculated for each demographic variable and tested for statistically significant differences by analysis of variance. Questions within each domain that were internally consistent with each other within domains were identified by Cronbach's alpha ≥ 0.7. P-values ≤ 0.05 were considered statistically significant. Cronbach's alpha analysis showed strong internal consistency for 10 dependent outcome questions in the practice factor-related domain (α = 0.72), 6 dependent outcome questions in the peer factor-related domain (α = 0.71), and 8 dependent outcome questions in the personal factor-related domain (α = 0.81). Although age was not a variable, full-time status, early satisfaction within the first 5 years of practice, working with respected peers, and personal choice factors were all significantly associated with anesthesiologist job satisfaction. Improvements in factors related to job satisfaction among anesthesiologists may lead to higher early and current career satisfaction. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Policy instruments for energy conservation and environmental policy in the Netherlands

    Energy Technology Data Exchange (ETDEWEB)

    Bovenberg, A.L. [Tinbergen Inst., Rotterdam (Netherlands)

    1992-03-01

    In this paper it is assumed that the policy objective is not so much to economize on energy as to reduce pollution. In particular, to curb the emissions of carbon dioxide. A number of environmental policy instruments pertaining to fossil fuels are analyzed, mainly in the context of the Dutch economy: regulation, subsidies, voluntary agreements with industry, and taxation. At the moment, most industrial countries, including the Netherlands, rely almost entirely on the first three instruments. More recently, however, there has been a growing interest in environmental taxation. The theory that taxation is always and everywhere the best instrument assumes, however, perfect markets and a closed economy. Most economies, including the Dutch one, are riddled with market imperfections. Hence, policy makers confront a second best case. This implies that in selecting policy instruments, they have to resort to a more pragmatic `case-by-case` approach. A diversified diet is advocated. Taxation is part of that diet. Section 2 explores a number of important advantages of the tax instrument. Section 3 discusses a number of problems if a small open economy like the Netherlands would unilaterally adopt such a tax, especially if that tax would include energy-intensive firms that are subject to international competition. In this connection, some alternative policy instruments are analyzed in Section 4. Section 5 proceeds by investigating the case of international coordination and explores the conditions under which coordinated taxes could be successful. Section 6 analyzes policies targeted at households and at firms that are not subject to international competition. 13 refs.

  5. International Working Group on Nuclear Power Plant Control and Instrumentation: Recent activities and future prospects

    International Nuclear Information System (INIS)

    Kossilov, A.

    1992-01-01

    The IWG-NPPCI working group exists to consider developments, disseminate and exchange experience in all aspects of instrumentation, control and information technology relevant to the safety and economics of NPP design and operation. The main topics dealt with are: nuclear instrumentation, control systems, protection systems, early failure detection and diagnosis, use of computer technology in NPP operation, instrumentation for accidental situation, operator support systems, man-machine interface. The main objectives of the IWG-NPPCI are: to assist the IAEA to provide the Member States with information and recommendations on technical aspects of the NPP control and instrumentation with the aim to assure reliable functions; to promote and exchange of information on national programs, new developments and experience from operating NPPs, and to stimulate the coordination of research on NPP control and instrumentation

  6. International Working Group on Nuclear Power Plant Control and Instrumentation: Recent activities and future prospects

    Energy Technology Data Exchange (ETDEWEB)

    Kossilov, A [International Atomic Energy Agency, Vienna (Austria)

    1992-07-01

    The IWG-NPPCI working group exists to consider developments, disseminate and exchange experience in all aspects of instrumentation, control and information technology relevant to the safety and economics of NPP design and operation. The main topics dealt with are: nuclear instrumentation, control systems, protection systems, early failure detection and diagnosis, use of computer technology in NPP operation, instrumentation for accidental situation, operator support systems, man-machine interface. The main objectives of the IWG-NPPCI are: to assist the IAEA to provide the Member States with information and recommendations on technical aspects of the NPP control and instrumentation with the aim to assure reliable functions; to promote and exchange of information on national programs, new developments and experience from operating NPPs, and to stimulate the coordination of research on NPP control and instrumentation.

  7. CAMAC-an international standard for data machine instrumentation

    CERN Document Server

    Johnsen, P J

    1973-01-01

    CAMAC is a standard for on-line computer instrumentation and control. Owing to the world-wide acceptance of CAMAC, standardized and mutually compatible equipment is now offered by a great number of manufacturers. CAMAC systems are modular, and with the range of modules commercially available, it is possible to build up flexible and complex data processing systems. Use of CAMAC requires a CAMAC- compatible entrance (interface) to the computer. Once established, users are later on completely independent of the type of computer used. General aspects, CAMAC systems for NORD-1 and NORD-10 are presented. The former is developed at Physics Institute, Oslo, and the latter is developed as a result of the CERN-contract gained by NORSK DATAELEKTRONIKK.

  8. Systematic review of studies on measurement properties of instruments for adults published in the American Journal of Occupational Therapy, 2009-2013.

    Science.gov (United States)

    Yuen, Hon K; Austin, Sarah L

    2014-01-01

    We describe the methodological quality of recent studies on instrument development and testing published in the American Journal of Occupational Therapy (AJOT). We conducted a systematic review using the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist to appraise 48 articles on measurement properties of assessments for adults published in AJOT between 2009 and 2013. Most studies had adequate methodological quality in design and statistical analysis. Common methodological limitations included that methods used to examine internal consistency were not consistently linked to the theoretical constructs underpinning assessments; participants in some test-retest reliability studies were not stable during the interim period; and in several studies of reliability and convergent validity, sample sizes were inadequate. AJOT's dissemination of psychometric research evidence has made important contributions to moving the profession toward the American Occupational Therapy Association's Centennial Vision. This study's results provide a benchmark by which to evaluate future accomplishments. Copyright © 2014 by the American Occupational Therapy Association, Inc.

  9. Validation of a psychometric instrument to assess motivation in veterinary bachelor students.

    Science.gov (United States)

    Vandeweerd, Jean-Michel; Dugdale, Alexandra; Romainville, Marc

    2014-01-01

    There are indications that motivation correlates with better performance for those studying veterinary medicine. To assess objectively whether motivation profiles influence both veterinary students' attitudes towards educational interventions and their academic success and whether changes in curriculum can affect students' motivation, there is need for an instrument that can provide a valid measurement of the strength of motivation for the study of veterinary medicine. Our objectives were to design and validate a questionnaire that can be used as a psychometric scale to capture the motivation profiles of veterinary students. Question items were obtained from semi-structured interviews with students and from a review of the relevant literature. Each item was scored on a 5-point scale. The preliminary instrument was trialed on a cohort of 450 students. Responses were subjected to reliability and principal component analysis. A 14-item scale was designed, within which two factors explained 53.4% of the variance among the items. The scale had good face, content, and construct validities as well as a good internal consistency (Cronbach's alpha=.88).

  10. Endotoxins in surgical instruments of hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Vania Regina Goveia

    2016-06-01

    Full Text Available Abstract OBJECTIVE To investigate endotoxins in sterilized surgical instruments used in hip arthroplasties. METHOD A descriptive exploratory study conducted in a public teaching hospital. Six types of surgical instruments were selected, namely: acetabulum rasp, femoral rasp, femoral head remover, chisel box, flexible bone reamer and femoral head test. The selection was based on the analysis of the difficulty in removing bone and blood residues during cleaning. The sample was made up of 60 surgical instruments, which were tested for endotoxins in three different stages. The EndosafeTM Gel-Clot LAL (Limulus Amebocyte Lysate method was used. RESULT There was consistent gel formation with positive analysis in eight instruments, corresponding to 13.3%, being four femoral rasps and four bone reamers. CONCLUSION Endotoxins in quantity ≥0.125 UE/mL were detected in 13.3% of the instruments tested.

  11. Instrumentation for PSD-based neutron diffractometers at Dhruva reactor

    Science.gov (United States)

    Pande, S. S.; Borkar, S. P.; Prafulla, S.; Srivastava, V. D.; Behare, A.; Mukhopadhyay, P. K.; Ghodgaonkar, M. D.; Kataria, S. K.

    2004-08-01

    Linear position sensitive detectors (PSDs) are widely used to configure neutron diffractometers and other instruments. Necessary front-end electronics and a data acquisition system [1] is developed to cater to such instruments built around the Dhruva research reactor in BARC. These include three diffractometers with multiple PSDs and four with single PSD. The front-end electronics consists of high voltage units, preamplifiers [2], shaping amplifiers, ratio ADCs (RDC) [3]. The data acquisition system consists of an interface card and software. Commercially available hardware like temperature controller or stepper motor controller connected over GPIB or RS232 are also integrated in the data acquisition system. The data acquisition is automated so that it can continue unattended for control parameter like temperature, thus enabling optimum utilization of available beam time. The instrumentation is scalable and can be easily configured for various instrumental requirements. The front-end electronics and the data acquisition system are described here.

  12. Reliability and Validity of Three Instruments (DSM-IV, CPGI, and PPGM) in the Assessment of Problem Gambling in South Korea.

    Science.gov (United States)

    Back, Ki-Joon; Williams, Robert J; Lee, Choong-Ki

    2015-09-01

    Most research on the assessment, epidemiology, and treatment of problem gambling has occurred in Western jurisdictions. This potentially limits the cross-cultural validity of problem gambling assessment instruments as well as etiological models of problem gambling. The primary objective of the present research was to investigate the reliability and validity of three problem gambling assessment instruments within a South Korean context. A total of 4,330 South Korean adults participated in a comprehensive assessment of their gambling behavior that included the administration of the DSM-IV criteria for pathological gambling (NODS), the Canadian Problem Gambling Index (CPGI), and the Problem and Pathological Gambling Measure (PPGM). Cronbach alpha showed that all three instruments had good internal consistency. Concurrent validity was established by the significant associations observed between scores on the instruments and measures of gambling involvement (number of gambling formats engaged in; frequency of gambling; and gambling expenditure). Most importantly, kappa statistics showed that all instruments have satisfactory classification accuracy against clinical assessment of problem gambling conducted by South Korean clinicians (NODS κ = .66; PPGM κ = .62; CPGI κ = .51). These results confirm that Western-derived operationalizations of problem gambling have applicability in a South Korean setting.

  13. Calibration of radiation protection area monitoring instruments in Sudan

    International Nuclear Information System (INIS)

    Suliman, I.I.; Youssif, B.E.; Beineen, A.A.; Hassan, M.

    2010-01-01

    This article presents results of measurements for the calibration of radiation protection area monitoring instruments carried out during the period 2006-2008 at Secondary Standard Dosimetry Laboratory of Sudan. The work performed included quality assurance measurements, measurements for the dosimeter calibrations and uncertainty analysis. Calibrations were performed using 137 Cs gamma ray sources produced by OB 85 and OB 34/1 gamma calibrators producing air kerma rate that ranged from 10 μGy/h to 50 mGy/h. Area monitoring instruments were calibrated in terms of ambient dose equivalent, H*(10) derived using air kerma to ambient dose equivalent conversion coefficients. Results are presented for 78 area monitoring instruments representing most commonly used types in Sudan. Radioactive check source measurements for the reference chamber showed deviation within 1% limit. The accuracy in the beam output measurements was within 5% internationally considered as acceptable. The results highlighted the importance of radiation protection calibrations. Regulations are further need to ensure safety aspect really meet the required international standards.

  14. IHY - An International Cooperative Program

    Science.gov (United States)

    Rabello-Soares, M. Cristina; Davila, J.; Gopalswamy, N.; Thompson, B.

    2007-05-01

    The International Heliophysical Year (IHY) in 2007/2008 involves thousands of scientists representing over 70 nations. It consists of four distinct elements that will be described here. Taking advantage of the large amount of heliophysical data acquired routinely by a vast number of sophisticated instruments aboard space missions and at ground-based observatories, IHY aims to develop the basic science of heliophysics through cross-disciplinary studies of universal processes by means of Coordinated Investigation Programs (CIPs). The second component is in collaboration with the United Nations Basic Space Science Initiative (UNBSSI) and consists of the deployment of arrays of small, inexpensive instruments such as magnetometers, radio antennas, GPS receivers, etc. around the world to provide global measurements. An important aspect of this partnership is to foster the participation of developing nations in heliophysics research. IHY coincides with the commemoration of 50 years of the space age that started with launch of Sputnik on October 4, 1957 and it is on the brink of a new age of space exploration where the Moon, Mars and the outer planets will be the focus of the space programs in the next years. As a result, it presents an excellent opportunity to create interest for science among young people with the excitement of discovery of space. The education and outreach program forms another cornerstone of IHY. Last but not least, an important part of the IHY activities, its forth component, is to preserve the history and memory of IGY 1957.

  15. Instrument development and evaluation for patient-related outcomes assessments

    Directory of Open Access Journals (Sweden)

    Farnik M

    2012-03-01

    Full Text Available Małgorzata Farnik, Władysław PierzchałaDepartment of Pneumonology, Silesian University of Medicine, Katowice, PolandAbstract: Patient-related outcomes measures could provide important information for the current state of the art in medical care and even have an impact on macrodecisions in the health care system. Patient-related outcomes were initially defined as subjective health indicators that allow disability and illness to be assessed, based on patient, caregiver, or physician self-reports. As illness involves psychological and behavioral complex processes of care, a multidisciplinary approach in measuring patient-reported outcomes should be recommended, such as quality of life questionnaires. Patient-related outcomes measures should correspond to specific clinical situations and bring opportunities to improve quality of care. Objective measurements enable quantitative data to be collected and analyzed. Depending on the aim of the research, investigators can use existing methods or develop new tools. This publication presents a methodology for developing patient-related outcomes measures, based on a multistage procedure. The proper definition of specific study objectives and the methodology of instrument development are crucial for successfully transferring the study concept. The model of instrument development is the process of starting from the preliminary phase and includes questionnaire design and scaling, pilot testing (cognitive debriefing, revision of the preliminary version, evaluation of the new tool, and implementation. Validation of the new instrument includes reliability, reproducibility, internal consistency, and responsiveness. The process of designing the new tool should involve a panel of experts, including clinicians, psychologists (preliminary phase, and statisticians (scale development and scoring, and patients (cognitive debriefing. Implementation of a new tool should be followed by evaluation study – assessment of

  16. Evaluation of the FOCUS (Feedback on Counseling Using Simulation) instrument for assessment of client-centered nutrition counseling behaviors.

    Science.gov (United States)

    Henry, Beverly W; Smith, Thomas J

    2010-01-01

    To develop an instrument to assess client-centered counseling behaviors (skills) of student-counselors in a standardized patient (SP) exercise. Descriptive study of the accuracy and utility of a newly developed counseling evaluation instrument. Study participants included 11 female student-counselors at a Midwestern university-10 Caucasian, 1 African-American-for the simulated counseling sessions, in which the Feedback on Counseling Using Simulation (FOCUS) instrument was applied in 2 SP scenarios (cardiovascular disease and diabetes). FOCUS ratings of student-counselors by 4 SPs during 22 sessions were compared with ratings from a 3-member panel of experts who independently viewed the 22 videotaped sessions. Quantitative analysis of instrument validity included inter-rater reliability by computing generalizability coefficients, Pearson correlations, and Spearman rank-order correlations. FOCUS criteria encompassed relevant dimensions of nutrition counseling based in a client-centered perspective. The critical points of information gathering and counseling behaviors showed internal consistency overall and good inter-rater reliability with the cardiovascular disease scenario. For both scenarios, pooled ratings of 3 experts agreed with ratings carried out by SPs. Initial findings suggest that the FOCUS instrument with client-centered criteria may enhance evaluation of counseling skills in SP exercises, meriting further study with larger groups.

  17. Psychometric evaluation of a new instrument to measure disease self-management of the early stage chronic kidney disease patients.

    Science.gov (United States)

    Lin, Chiu-Chu; Wu, Chia-Chen; Wu, Li-Min; Chen, Hsing-Mei; Chang, Shu-Chen

    2013-04-01

    This study aims to develop a valid and reliable chronic kidney disease self-management instrument (CKD-SM) for assessing early stage chronic kidney disease patients' self-management behaviours. Enhancing early stage chronic kidney disease patients' self-management plays a key role in delaying the progression of chronic kidney disease. Healthcare provider understanding of early stage chronic kidney disease patients' self-management behaviours can help develop effective interventions. A valid and reliable instrument for measuring chronic kidney disease patients' self-management behaviours is needed. A cross-sectional descriptive study collected data for principal components analysis with oblique rotation. Mandarin- or Taiwanese-speaking adults with chronic kidney disease (n=252) from two medical centres and one regional hospital in Southern Taiwan completed the CKD-SM. Construct validity was evaluated by exploratory factor analysis. Internal consistency and test-retest reliability were estimated by Cronbach's alpha and Pearson correlation coefficients. Four factors were extracted and labelled self-integration, problem-solving, seeking social support and adherence to recommended regimen. The four factors accounted for 60.51% of the total variance. Each factor showed acceptable internal reliability with Cronbach's alpha from 0.77-0.92. The test-retest correlations for the CKD-SM was 0.72. The psychometric quality of the CKD-SM instrument was satisfactory. Research to conduct a confirmatory factor analysis to further validate this new instrument's construct validity is recommended. The CKD-SM instrument is useful for clinicians who wish to identify the problems with self-management among chronic kidney disease patients early. Self-management assessment will be helpful to develop intervention tailored to the needs of the chronic kidney disease population. © 2013 Blackwell Publishing Ltd.

  18. Backscattering at a pulsed neutron source, the MUSICAL instrument

    International Nuclear Information System (INIS)

    Alefeld, B.

    1995-01-01

    In the first part the principles of the neutron backscattering method are described and some simple considerations about the energy resolution and the intensity are presented. A prototype of a backscattering instrument, the first Juelich instrument, is explained in some detail and a representative measurement is shown which was performed on the backscattering instrument IN10 at the ILL in Grenoble. In the second part a backscattering instrument designed for a pulsed neutron source is proposed. It is shown that a rather simple modification, which consists in the replacement of the Doppler drive of the conventional backscattering instrument by a multi silicon monochromator crystal (MUSICAL) leads to a very effective instrument, benefitting from the peak flux of the pulsed source. ((orig.))

  19. Fitness to plead: Development and validation of a standardised assessment instrument.

    Directory of Open Access Journals (Sweden)

    Penelope Brown

    Full Text Available The ability of an individual to participate in courtroom proceedings is assessed by clinicians using legal 'fitness to plead' criteria. Findings of 'unfitness' are so rare that there is considerable professional unease concerning the utility of the current subjective assessment process. As a result, mentally disordered defendants may be subjected unfairly to criminal trials. The Law Commission in England and Wales has proposed legal reform, as well as the utilisation of a defined psychiatric instrument to assist in fitness to plead assessments. Similar legal reforms are occurring in other jurisdictions. Our objective was to produce and validate a standardised assessment instrument of fitness to plead employing a filmed vignette of criminal proceedings. The instrument was developed in consultation with legal and clinical professionals, and was refined using standard item reduction methods in two initial rounds of testing (n = 212. The factorial structure, test-retest reliability and convergent validity of the resultant instrument were assessed in a further round (n = 160. As a result of this iterative process a 25-item scale was produced, with an underlying two-factor structure representing the foundational and decision-making abilities underpinning fitness to plead. The sub-scales demonstrate good internal consistency (factor 1: 0·76; factor 2: 0·65 and test-retest stability (0·7 as well as excellent convergent validity with scores of intelligence, executive function and mentalising abilities (p≤0·01 in all domains. Overall the standardised Fitness to Plead Assessment instrument has good psychometric properties. It has the potential to ensure that the significant numbers of mentally ill and cognitively impaired individuals who face trial are objectively assessed, and the courtroom process critically informed.

  20. Combining policy instruments to curb greenhouse gas emissions

    International Nuclear Information System (INIS)

    Bahn, O.

    2001-01-01

    The Kyoto Protocol has set greenhouse gas emission reduction targets for selected countries. To comply with these reduction requirements, decision-makers may use market-based instruments on a national or international basis. This paper advocates the combining of national emission taxes with international trade of emission permits. As a numerical application, this paper analyses macro-economic impacts of such a strategy for Switzerland. (Author)

  1. Land Subsidence International Symposium held in Venice

    Science.gov (United States)

    The Third International Symposium on Land Subsidence was held March 18-25, 1984, in Venice, Italy. Sponsors were the Ground-Water Commission of the International Association of Hydrological Sciences (IAHS), the United Nations Educational, Scientific, and Cultural Organization (UNESCO), the Italian National Research Council (CNR), the Italian Regions of Veneto and Emilia-Romagna, the Italian Municipalities of Venice, Ravenna, and Modena, the Venice Province, and the European Research Office. Cosponsors included the International Association of Hydrogeologists (IAH), the International Society for Soil Mechanics and Foundation Engineering (ISSMFE), and the Association of Geoscientists for International Development (AGID).Organized within the framework of UNESCO's International Hydrological Program, the symposium brought together over 200 international interdisciplinary specialists in the problems of land subsidence due to fluid and mineral withdrawal. Because man's continuing heavy development of groundwater, gas, oil, and minerals is changing the natural regime and thus causing more and more subsiding areas in the world, there had been sufficient new land subsidence occurrence, problems, research, and remedial measures since the 1976 Second International Symposium held in Anaheim, California, to develop a most interesting program of nearly 100 papers from about 30 countries. The program consisted of papers covering case histories of fluid and mineral withdrawal, engineering theory and analysis, karst “sink-hole”-type subsidence, subsidence due to dewatering of organic deposits or due to application of water (hydrocompaction), instrumentation, legal, socioeconomic, and environmental effects of land subsidence, and remedial works.

  2. REFERQUAL: a pilot study of a new service quality assessment instrument in the GP exercise referral scheme setting

    Science.gov (United States)

    Cock, Don; Adams, Iain C; Ibbetson, Adrian B; Baugh, Phil

    2006-01-01

    Background The development of an instrument accurately assessing service quality in the GP Exercise Referral Scheme (ERS) industry could potentially inform scheme organisers of the factors that affect adherence rates leading to the implementation of strategic interventions aimed at reducing client drop-out. Methods A modified version of the SERVQUAL instrument was designed for use in the ERS setting and subsequently piloted amongst 27 ERS clients. Results Test re-test correlations were calculated via Pearson's 'r' or Spearman's 'rho', depending on whether the variables were Normally Distributed, to show a significant (mean r = 0.957, SD = 0.02, p < 0.05; mean rho = 0.934, SD = 0.03, p < 0.05) relationship between all items within the questionnaire. In addition, satisfactory internal consistency was demonstrated via Cronbach's 'α'. Furthermore, clients responded favourably towards the usability, wording and applicability of the instrument's items. Conclusion REFERQUAL is considered to represent promise as a suitable tool for future evaluation of service quality within the ERS community. Future research should further assess the validity and reliability of this instrument through the use of a confirmatory factor analysis to scrutinise the proposed dimensional structure. PMID:16725021

  3. High-performance instruments in neutron arena of JHP. Preliminary version

    International Nuclear Information System (INIS)

    Furusaka, M.; Itoh, S.; Otomo, T.; Arai, M.

    1996-05-01

    This report is a preliminary report of high-performance instruments in neutron arena of JHP (Japan Hadron Project). This report consists of as follows; neutron intensity of neutron arena, development of neutron sources in neutron arena, experimental devices and instrumentation. (J.P.N.)

  4. Frame, methods and instruments for energy planning in the new economic order of electricity economics

    International Nuclear Information System (INIS)

    Stigler, H.

    1999-01-01

    The introduction of the new economic order of the electricity economy causes new focal tasks for the individual market participants and therefore new requirements for planning. As a precondition for energy planning, the Internal Market Electricity Directive and the ElWOG are examined and the tasks for the market participants are derived. Liberalization raises the risks for the enterprises. Increasing competition sets up higher requirements for planning. The planning instruments have no longer the destination of minimum costs but have to maximize the results of the enterprise. Price fixing requires a raised alignment to marginal costs considerations. Increasing electricity trade requires the introduction of new planning instruments. Further new tasks refer to electricity transfer via other networks and especially to congestion management. New chances but also new risks arise for the renewable energy sources. From the market result new requirements for the planning instruments. The basics in this respect are prepared and concrete examples from practice are submitted. Models of enterprises are developed, which consist of a technical and a business part. Central importance has the modeling of competition in the liberalized market. A model of competition between enterprises in the electricity market is developed. (author)

  5. The Children's Sleep Comic: Psychometrics of a Self-rating Instrument for Childhood Insomnia.

    Science.gov (United States)

    Schwerdtle, Barbara; Kanis, Julia; Kübler, Andrea; Schlarb, Angelika A

    2016-02-01

    The Children's Sleep Comic is a standardized self-report questionnaire for assessing insomnia in children ages 5-11 years. The goal of the present study is to introduce a revised version of this measure and to present psychometrics and a cut-off score. Therefore, the revised Children's Sleep Comic, the Sleep Self Report, the Children's Sleep Habits Questionnaire, and the Child Behavior Checklist were applied to a sample of 393 children and their parents. Of the parents who participated voluntarily, a subsample (n = 176) was interviewed on the phone to diagnose their children with sleep disorders according to the International Classification of Sleep Disorders, if applicable. The results indicated that the Children's Sleep Comic is a reliable self-rating instrument for diagnosing childhood insomnia. Internal consistency was α = 0.83; and convergent and divergent validity were adequate. The child-friendly format can foster a good therapeutic relationship, and thus establish the basis for successful intervention.

  6. Evolution and validation of a personal form of an instrument for assessing science laboratory classroom environments

    Science.gov (United States)

    Fraser, Barry J.; Giddings, Geoffrey J.; McRobbie, Campbell J.

    The research reported in this article makes two distinctive contributions to the field of classroom environment research. First, because existing instruments are unsuitable for science laboratory classes, the Science Laboratory Environment Inventory (SLEI) was developed and validated. Second, a new Personal form of the SLEI (involving a student's perceptions of his or her own role within the class) was developed and validated in conjunction with the conventional Class form (involving a student's perceptions of the class as a whole), and its usefulness was investigated. The instrument was cross-nationally fieldtested with 5,447 students in 269 senior high school and university classes in six countries, and cross-validated with 1,594 senior high school students in 92 classes in Australia. Each SLEI scale exhibited satisfactory internal consistency reliability, discriminant validity, and factorial validity, and differentiated between the perceptions of students in different classes. A variety of applications with the new instrument furnished evidence about its usefulness and revealed that science laboratory classes are dominated by closed-ended activities; mean scores obtained on the Class form were consistently somewhat more favorable than on the corresponding Personal form; females generally held more favorable perceptions than males, but these differences were somewhat larger for the Personal form than the Class form; associations existed between attitudinal outcomes and laboratory environment dimensions; and the Class and Personal forms of the SLEI each accounted for unique variance in student outcomes which was independent of that accounted for by the other form.

  7. Developing consistent pronunciation models for phonemic variants

    CSIR Research Space (South Africa)

    Davel, M

    2006-09-01

    Full Text Available Pronunciation lexicons often contain pronunciation variants. This can create two problems: It can be difficult to define these variants in an internally consistent way and it can also be difficult to extract generalised grapheme-to-phoneme rule sets...

  8. Leveraging non-binding instruments for global health governance: reflections from the Global AIDS Reporting Mechanism for WHO reform.

    Science.gov (United States)

    Taylor, A L; Alfven, T; Hougendobler, D; Tanaka, S; Buse, K

    2014-02-01

    As countries contend with an increasingly complex global environment with direct implications for population health, the international community is seeking novel mechanisms to incentivize coordinated national and international action towards shared health goals. Binding legal instruments have garnered increasing attention since the World Health Organization adopted its first convention in 2003. This paper seeks to expand the discourse on future global health lawmaking by exploring the potential value of non-binding instruments in global health governance, drawing on the case of the 2001 United Nations General Assembly Special Session Declaration of Commitment on HIV/AIDS. In other realms of international concern ranging from the environment to human rights to arms control, non-binding instruments are increasingly used as effective instruments of international cooperation. The experience of the Global AIDS Reporting Mechanism, established pursuant to the Declaration, evidences that, at times, non-binding legal instruments can offer benefits over slower, more rigid binding legal approaches to governance. The global AIDS response has demonstrated that the use of a non-binding instrument can be remarkably effective in galvanizing increasingly deep commitments, action, reporting compliance and ultimately accountability for results. Based on this case, the authors argued that non-binding instruments deserve serious consideration by the international community for the future of global health governance, including in the context of WHO reform. Copyright © 2013 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  9. Polyphonic pitch detection and instrument separation

    Science.gov (United States)

    Bay, Mert; Beauchamp, James W.

    2005-09-01

    An algorithm for polyphonic pitch detection and musical instrument separation is presented. Each instrument is represented as a time-varying harmonic series. Spectral information is obtained from a monaural input signal using a spectral peak tracking method. Fundamental frequencies (F0s) for each time frame are estimated from the spectral data using an Expectation Maximization (EM) algorithm with a Gaussian mixture model representing the harmonic series. The method first estimates the most predominant F0, suppresses its series in the input, and then the EM algorithm is run iteratively to estimate each next F0. Collisions between instrument harmonics, which frequently occur, are predicted from the estimated F0s, and the resulting corrupted harmonics are ignored. The amplitudes of these corrupted harmonics are replaced by harmonics taken from a library of spectral envelopes for different instruments, where the spectrum which most closely matches the important characteristics of each extracted spectrum is chosen. Finally, each voice is separately resynthesized by additive synthesis. This algorithm is demonstrated for a trio piece that consists of 3 different instruments.

  10. Consistent Valuation across Curves Using Pricing Kernels

    Directory of Open Access Journals (Sweden)

    Andrea Macrina

    2018-03-01

    Full Text Available The general problem of asset pricing when the discount rate differs from the rate at which an asset’s cash flows accrue is considered. A pricing kernel framework is used to model an economy that is segmented into distinct markets, each identified by a yield curve having its own market, credit and liquidity risk characteristics. The proposed framework precludes arbitrage within each market, while the definition of a curve-conversion factor process links all markets in a consistent arbitrage-free manner. A pricing formula is then derived, referred to as the across-curve pricing formula, which enables consistent valuation and hedging of financial instruments across curves (and markets. As a natural application, a consistent multi-curve framework is formulated for emerging and developed inter-bank swap markets, which highlights an important dual feature of the curve-conversion factor process. Given this multi-curve framework, existing multi-curve approaches based on HJM and rational pricing kernel models are recovered, reviewed and generalised and single-curve models extended. In another application, inflation-linked, currency-based and fixed-income hybrid securities are shown to be consistently valued using the across-curve valuation method.

  11. Reliability of instruments in a cooperative, multisite study: employment intervention demonstration program.

    Science.gov (United States)

    Salyers, M P; McHugo, G J; Cook, J A; Razzano, L A; Drake, R E; Mueser, K T

    2001-09-01

    Reliability of well-known instruments was examined in 202 people with severe mental illness participating in a multisite vocational study. We examined interrater reliability of the Positive and Negative Syndrome Scale (PANSS) and the internal consistency and test-retest reliability of the PANSS, the Rosenberg Self-Esteem Scale, the Medical Outcomes Study Short Form-36 (SF-36), and the Quality of Life Interview. Most scales had good levels of reliability, with intraclass correlation coefficients (ICCs) and coefficient alphas above .70. However, the SF-36 scales were generally less stable over time, particularly Social Functioning (ICC = .55). Test-retest reliability was lower among less educated respondents and among ethnic minorities. We recommend close monitoring of psychometric issues in future multisite studies.

  12. Development of an instrument to assess readiness to recover in anorexia nervosa.

    Science.gov (United States)

    Rieger, E; Touyz, S; Schotte, D; Beumont, P; Russell, J; Clarke, S; Kohn, M; Griffiths, R

    2000-12-01

    The degree to which patients with anorexia nervosa demonstrate readiness to recover from their illness has received scant theoretical or empirical attention. Investigating the prevalence and degree of amotivation for recovery in anorexia nervosa, its role in outcome, and the effectiveness of interventions designed to enhance readiness to recover necessitates the existence of a reliable and valid measure of motivational issues relevant to the disorder. The present study aimed to develop and evaluate an instrument for assessing readiness to recover in anorexia nervosa, namely, the Anorexia Nervosa Stages of Change Questionnaire (ANSOCQ), a 23-item self-report questionnaire based on Prochaska and DiClemente's stages of change model. Seventy-one inpatients with anorexia nervosa participated in the study. On several occasions during their admission, participants completed the ANSOCQ as well as questionnaires assessing readiness to recover, anorexic symptomatology, general distress, and social desirability. The ANSOCQ demonstrated good internal consistency (.90) and 1-week test-retest reliability (.89). Various aspects of validity were also supported, such as significant relationships with other instruments assessing readiness to recover and the prediction of weight gain during different periods of treatment. The results suggest that the ANSOCQ is a psychometrically sound instrument that may prove useful in investigating the role of readiness to recover in anorexia nervosa. Copyright 2000 John Wiley & Sons, Inc.

  13. Design and development of control instrumentation for the superconducting Linear Accelerator

    International Nuclear Information System (INIS)

    Joshi, Gopal; Kapatral, R.S.; Jha, K.; Rathod, N.C.; Sujo, C.I.; Ananthakrishnan, T.S.; Narsaiah, A.; Ghodgaonkar, M.D.; Kataria, S.K.; Singh, S.K.

    2001-01-01

    Electronics Division, BARC is developing the required control instrumentation for the Linear Accelerator (LINAC) coming up at TIFR. This consists of RF systems, CAMAC instruments and the Control and Information System. The control system consists of several identical Local Control Stations (LCS) connected over a LAN to a Main Control Station (MCS). Each LCS consists of a PC, CAMAC crates with functional Modules and RF systems. The MCS will contain two PCs running identical software. Each LCS will cater to two LINAC module each consisting of one cryostat and four resonators. This paper discusses different systems developed and under development in the Electronics Division which play an important role in the control of the LINAC. (author)

  14. Thermo Scientific Ozone Analyzer Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Springston, S. R. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-03-01

    The primary measurement output from the Thermo Scientific Ozone Analyzer is the concentration of the analyte (O3) reported at 1-s resolution in units of ppbv in ambient air. Note that because of internal pneumatic switching limitations the instrument only makes an independent measurement every 4 seconds. Thus, the same concentration number is repeated roughly 4 times at the uniform, monotonic 1-s time base used in the AOS systems. Accompanying instrument outputs include sample temperatures, flows, chamber pressure, lamp intensities and a multiplicity of housekeeping information. There is also a field for operator comments made at any time while data is being collected.

  15. Jovian seismology: preliminary results of the SYMPA instrument

    Science.gov (United States)

    Gaulme, P.; Schmider, F. X.; Gay, J.; Jacob, C.; Jeanneaux, F.; Alvarez, M.; Reyes, M.; Valtier, J. C.; Fossat, E.; Palle, P. L.; Belmonte, J. C.; Gelly, B.

    2006-06-01

    Jupiter's internal structure is poorly known (Guillot et al. 2004). Seismology is a powerful tool to investigate the internal structure of planets and stars, by analyzing how acoustic waves propagate. Mosser (1997) and Gudkova & Zarkhov (1999) showed that the detection and the identification of non-radial modes up to degree ℓ=25 can constrain strongly the internal structure. SYMPA is a ground-based network project dedicated to the Jovian oscillations (Schmider et al. 2002). The instrument is composed of a Mach-Zehnder interferometer producing four interferograms of the planetary spectrum. The combination of the four images in phase quadrature allows the reconstruction of the incident light phase, which is related to the Doppler shift generated by the oscillations. Two SYMPA instruments were built at the Nice university and were used simultaneously during two observation campaigns, in 2004 and 2005, at the San Pedro Martir observatory (Mexico) and the Teide observatory (Las Canarias). We will present for the first time the data processing and the preliminary results of the experiment.

  16. The Rucio Consistency Service

    CERN Document Server

    Serfon, Cedric; The ATLAS collaboration

    2016-01-01

    One of the biggest challenge with Large scale data management system is to ensure the consistency between the global file catalog and what is physically on all storage elements. To tackle this issue, the Rucio software which is used by the ATLAS Distributed Data Management system has been extended to automatically handle lost or unregistered files (aka Dark Data). This system automatically detects these inconsistencies and take actions like recovery or deletion of unneeded files in a central manner. In this talk, we will present this system, explain the internals and give some results.

  17. Cross-cultural adaptation, reliability, internal consistency and validation of the Hand Function Sort (HFS©) for French speaking patients with upper limb complaints.

    Science.gov (United States)

    Konzelmann, M; Burrus, C; Hilfiker, R; Rivier, G; Deriaz, O; Luthi, F

    2015-03-01

    Functional evaluation of upper limb is not only based on clinical findings but requires self-administered questionnaires to address patients' perspective. The Hand Function Sort (HFS©) was only validated in English. The aim of this study was the French cross cultural adaptation and validation of the HFS© (HFS-F). 150 patients with various upper limbs impairments were recruited in a rehabilitation center. Translation and cross-cultural adaptation were made according to international guidelines. Construct validity was estimated through correlations with Disabilities Arm Shoulder and Hand (DASH) questionnaire, SF-36 mental component summary (MCS),SF-36 physical component summary (PCS) and pain intensity. Internal consistency was assessed by Cronbach's α and test-retest reliability by intraclass correlation. Cronbach's α was 0.98, test-retest reliability was excellent at 0.921 (95 % CI 0.871-0.971) same as original HFS©. Correlations with DASH were-0.779 (95 % CI -0.847 to -0.685); with SF 36 PCS 0.452 (95 % CI 0.276-0.599); with pain -0.247 (95 % CI -0.429 to -0.041); with SF 36 MCS 0.242 (95 % CI 0.042-0.422). There were no floor or ceiling effects. The HFS-F has the same good psychometric properties as the original HFS© (internal consistency, test retest reliability, convergent validity with DASH, divergent validity with SF-36 MCS, and no floor or ceiling effects). The convergent validity with SF-36 PCS was poor; we found no correlation with pain. The HFS-F could be used with confidence in a population of working patients. Other studies are necessary to study its psychometric properties in other populations.

  18. Bootstrap embedding: An internally consistent fragment-based method

    Energy Technology Data Exchange (ETDEWEB)

    Welborn, Matthew; Tsuchimochi, Takashi; Van Voorhis, Troy [Department of Chemistry, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139 (United States)

    2016-08-21

    Strong correlation poses a difficult problem for electronic structure theory, with computational cost scaling quickly with system size. Fragment embedding is an attractive approach to this problem. By dividing a large complicated system into smaller manageable fragments “embedded” in an approximate description of the rest of the system, we can hope to ameliorate the steep cost of correlated calculations. While appealing, these methods often converge slowly with fragment size because of small errors at the boundary between fragment and bath. We describe a new electronic embedding method, dubbed “Bootstrap Embedding,” a self-consistent wavefunction-in-wavefunction embedding theory that uses overlapping fragments to improve the description of fragment edges. We apply this method to the one dimensional Hubbard model and a translationally asymmetric variant, and find that it performs very well for energies and populations. We find Bootstrap Embedding converges rapidly with embedded fragment size, overcoming the surface-area-to-volume-ratio error typical of many embedding methods. We anticipate that this method may lead to a low-scaling, high accuracy treatment of electron correlation in large molecular systems.

  19. Construct validity, test-retest reliability and internal consistency of the Thai version of the disabilities of the arm, shoulder and hand questionnaire (DASH-TH) in patients with carpal tunnel syndrome.

    Science.gov (United States)

    Buntragulpoontawee, Montana; Phutrit, Suphatha; Tongprasert, Siam; Wongpakaran, Tinakon; Khunachiva, Jeeranan

    2018-03-27

    This study evaluated additional psychometric properties of the Thai version of the disabilities of the arm, shoulder and hand questionnaire (DASH-TH) which included, test-retest reliability, construct validity, internal consistency of in patients with carpal tunnel syndrome. As for determining construct validity, the Thai EuroQOL questionnaire (EQ-5D-5L) was also administered in order to examine convergent and divergent validity. Fifty patients completed both questionnaires. The DASH-TH showed excellent test-retest reliability (intraclass correlation coefficient = 0.811) and internal consistency (Cronbach's alpha = 0.911). The exploratory factor analysis yielded a six-factor solution while the confirmatory factor analysis denoted that the hypothesized model adequately fit the data with a comparative fit index of 0.967 and a Tucker-Lewis index of 0.964. The related subscales between the DASH-TH and the Thai EQ-5D-5L were significantly correlated, indicating the DASH-TH's convergent and discriminant validity. The DASH-TH demonstrated good reliability, internal consistency construct validity, and multidimensionality, in assessing the upper extremity function in carpal tunnel syndrome patients.

  20. 21 CFR 882.4560 - Stereotaxic instrument.

    Science.gov (United States)

    2010-04-01

    ...) Identification. A stereotaxic instrument is a device consisting of a rigid frame with a calibrated guide mechanism for precisely positioning probes or other devices within a patient's brain, spinal cord, or other part of the nervous system. (b) Classification. Class II (performance standards). ...

  1. SERVQUAL x SERVPERF: comparação entre instrumentos para avaliação da qualidade de serviços internos SERVQUAL versus SERVPERF: a comparison of instruments for assessing internal service quality

    Directory of Open Access Journals (Sweden)

    Gilberto Gabriel Eid Salomi

    2005-08-01

    Full Text Available Nos últimos anos, diversos trabalhos têm considerado a importância da mensuração da qualidade por clientes externos às organizações. No entanto, qualquer organização industrial, não prescinde da avaliação de desempenho dos serviços internos como um meio para a melhoria contínua dos seus processos. Por isso, algumas pesquisas têm sugerido a utilização de instrumentos geralmente utilizados para mensuração da qualidade por clientes externos na avaliação de serviços internos. Nesse sentido, esse trabalho consiste na comparação de dois instrumentos, SERVPERF e SERVQUAL e suas variantes com ponderação, resultando em quatro instrumentos. No trabalho apresenta-se a aplicação destes instrumentos de qualidade de serviços na mensuração da qualidade de serviços internos em uma empresa do ramo industrial mecânico. Considera-se o serviço interno do departamento de manutenção industrial prestado às diversas células de manufatura em uma empresa fabricante de ferramentas industriais, profissionais e instrumentos de medição. Para a coleta dos dados foram aplicados questionários para os usuários dos serviços de manutenção e seus resultados foram analisados estatisticamente. O trabalho aponta que os valores obtidos para os instrumentos estudados são próximos entre si e comparáveis aos resultados da literatura. O artigo conclui também que o uso dos instrumentos SERVPERF e SERVQUAL para medida de qualidade do serviço de manutenção da empresa estudada foi viável, não havendo restrições quanto aos estimadores de confiabilidade e validade.Over the years, a number of papers have discussed the importance of measuring service quality based on the assessment of external customers. However, industrial organizations should also consider internal service performance evaluations as a means to achieve continuous process improvement. Therefore, researchers have suggested that the quality of internal services in industrial

  2. Instrument evaluation no. 10. Scanray radiation meter type 751

    CERN Document Server

    Burgess, P H; White, D F

    1978-01-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the a...

  3. Validation of the HIV/AIDS Stigma Instrument - PLWA (HASI-P).

    Science.gov (United States)

    Holzemer, William L; Uys, Leana R; Chirwa, Maureen L; Greeff, Minrie; Makoae, Lucia N; Kohi, Thecla W; Dlamini, Priscilla S; Stewart, Anita L; Mullan, Joseph; Phetlhu, René D; Wantland, Dean; Durrheim, Kevin

    2007-09-01

    This article describes the development and testing of a quantitative measure of HIV/AIDS stigma as experienced by people living with HIV/AIDS. This instrument is designed to measure perceived stigma, create a baseline from which to measure changes in stigma over time, and track potential progress towards reducing stigma. It was developed in three phases from 2003-2006: generating items based on results of focus group discussions; pilot testing and reducing the original list of items; and validating the instrument. Data for all phases were collected from five African countries: Lesotho, Malawi, South Africa, Swaziland and Tanzania. The instrument was validated with a sample of 1,477 persons living with HIV/AIDS from all of the five countries. The sample had a mean age of 36.1 years and 74.1% was female. The participants reported they knew they were HIV positive for an average of 3.4 years and 46% of the sample was taking antiretroviral medications. A six factor solution with 33 items explained 60.72% of the variance. Scale alpha reliabilities were examined and items that did not contribute to scale reliability were dropped. The factors included: Verbal Abuse (8 items, alpha=0.886); Negative Self-Perception (5 items, alpha=0.906); Health Care Neglect (7 items, alpha=0.832); Social Isolation (5 items, alpha=0.890); Fear of Contagion (6 items, alpha=0.795); and Workplace Stigma (2 items, alpha=0.758). This article reports on the development and validation of a new measure of stigma, HIV/AIDS Stigma Instrument - PLWA (HASI-P) providing evidence that supports adequate content and construct validity, modest concurrent validity, and acceptable internal consistency reliability for each of the six subscales and total score. The scale is available is several African languages.

  4. Instrumented Moles for Planetary Subsurface Regolith Studies

    Science.gov (United States)

    Richter, L. O.; Coste, P. A.; Grzesik, A.; Knollenberg, J.; Magnani, P.; Nadalini, R.; Re, E.; Romstedt, J.; Sohl, F.; Spohn, T.

    2006-12-01

    Soil-like materials, or regolith, on solar system objects provide a record of physical and/or chemical weathering processes on the object in question and as such possess significant scientific relevance for study by landed planetary missions. In the case of Mars, a complex interplay has been at work between impact gardening, aeolian as well as possibly fluvial processes. This resulted in regolith that is texturally as well as compositionally layered as hinted at by results from the Mars Exploration Rover (MER) missions which are capable of accessing shallow subsurface soils by wheel trenching. Significant subsurface soil access on Mars, i.e. to depths of a meter or more, remains to be accomplished on future missions. This has been one of the objectives of the unsuccessful Beagle 2 landed element of the ESA Mars Express mission having been equipped with the Planetary Underground Tool (PLUTO) subsurface soil sampling Mole system capable of self-penetration into regolith due to an internal electro-mechanical hammering mechanism. This lightweight device of less than 900 g mass was designed to repeatedly obtain and deliver to the lander regolith samples from depths down to 2 m which would have been analysed for organic matter and, specifically, organic carbon from potential extinct microbial activity. With funding from the ESA technology programme, an evolved Mole system - the Instrumented Mole System (IMS) - has now been developed to a readiness level of TRL 6. The IMS is to serve as a carrier for in situ instruments for measurements in planetary subsurface soils. This could complement or even eliminate the need to recover samples to the surface. The Engineering Model hardware having been developed within this effort is designed for accommodating a geophysical instrument package (Heat Flow and Physical Properties Package, HP3) that would be capable of measuring regolith physical properties and planetary heat flow. The chosen design encompasses a two-body Mole

  5. How To Control Color Appearance With Instrumentation

    Science.gov (United States)

    Burns, Margaret E.

    1980-05-01

    Colorimetry, as defined by the International Commission on Illumination, is the measurement of colors, made possible by the properties of the eye and based on a set of conventions. Instrumentation for measuring object color, therefore, must be based on a human observer. The intent is to design an instrument that in effect responds as a person would, so that research development, production control and quality control areas have some means of assessing the acceptability of the appearance of a product. Investigations of a human observer's psychological response to color, and the manner in which visual observations are made, give the instrument designer and manufacturer data necessary to answer two questions: a. How can we put numbers (instrument read-out) on a perception that occurs in the brain of the observer? b. What can we learn from examination of a visual observing situation that will guide us in our design of an instrumental simulation of this situation? Involving as it does our own daily, almost unconscious, practice of making judgments concerning the things we see, the design and manufacture of color measurement instruments is an exceedingly interesting field. The advances being made concurrently today in research concerning human color vision and in optical and electronic technology will make possible increasingly useful instrumentation for quality control of product color.

  6. Metallurgical characterization of controlled memory wire nickel-titanium rotary instruments.

    Science.gov (United States)

    Shen, Ya; Zhou, Hui-Min; Zheng, Yu-Feng; Campbell, Les; Peng, Bin; Haapasalo, Markus

    2011-11-01

    To improve the fracture resistance of nickel-titanium (NiTi) files, manufacturers have introduced new alloys and developed new manufacturing processes for the fabrication of NiTi files. This study aimed to examine the phase transformation behavior and microstructure of NiTi instruments from a novel controlled memory NiTi wire (CM wire). Instruments of EndoSequence (ES), ProFile (PF), ProFile Vortex (Vortex), Twisted Files (TF), Typhoon (TYP), and Typhoon™ CM (TYP CM), all size 25/.04, were examined by differential scanning calorimetry (DSC) and x-ray diffraction (XRD). Microstructures of etched instruments were observed by optical microscopy and scanning electron microscopy with x-ray energy-dispersive spectrometric (EDS) analyses. The DSC analyses showed that each segment of the TYP CM and Vortex instruments had an austenite transformation completion or austenite-finish (A(f)) temperature exceeding 37°C, whereas the NiTi instruments made from conventional superelastic NiTi wire (ES, PF, and TYP) and TF had A(f) temperatures substantially below mouth temperature. The higher A(f) temperature of TYP CM instruments was consistent with a mixture of austenite and martensite structure, which was observed at room temperature with XRD. All NiTi instruments had room temperature martensite microstructures consisting of colonies of lenticular features with substantial twinning. EDS analysis indicated that the precipitates in all NiTi instruments were titanium-rich, with an approximate composition of Ti(2)Ni. The TYP CM and Vortex instruments with heat treatment contribute to increase austenite transformation temperature. The CM instrument has significant changes in the phase transformation behavior, compared with conventional superelastic NiTi instruments. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. Assessing the validity of measures of an instrument designed to measure employees' perceptions of workplace breastfeeding support.

    Science.gov (United States)

    Greene, Sally W; Wolfe, Edward W; Olson, Beth H

    2008-09-01

    Breastfeeding rates among working mothers are lower than among mothers who are not employed. An ecological framework suggests that health behaviors, such as breastfeeding, are influenced by intrapersonal and environmental factors. There is no existing instrument to measure women's perception of the workplace environment in providing breastfeeding support. The objective of this study was to pilot an instrument measuring perceptions of the work climate for breastfeeding support among working women. Data were collected from self-administered mailed questionnaires filled out by 104 pregnant women or women who had recently given birth and were employed and breastfeeding. Dimensionally analyses supported the two-dimensional model suggested by the literature. Internal consistency reliability coefficients were high (near 0.90), and the correlation between the subscales was moderately strong (0.68). Only a single item exhibited misfit to the scaling model, and that item was revised after review.

  8. Validation of the Falls Efficacy Scale – International in a sample of Portuguese elderly

    Directory of Open Access Journals (Sweden)

    Cristina Maria Alves Marques-Vieira

    Full Text Available ABSTRACT Objective: to translate and adapt Falls Efficacy Scale – International (FES-I. To analyze the psychometric properties of the FES-I Portugal version. Method: psychometric study. Sample consisting of 170 elderly people residing in the Autonomous Region of Madeira. A two- part form was used (sociodemographic characterization and FES-I Portugal. The cross-cultural adaptation was performed and the following psychometric properties were evaluated: validity (construct, predictive, and discriminant, reliability (Cronbach’s alpha, and inter-rater reliability. Results: the results allow us to verify a dimension of less demanding physical activities and another of more demanding physical activities. The inter-rater reliability study was 0.62, with an interclass correlation coefficient of 0.859, for a 95% confidence interval. The internal consistency of the Portuguese version was 0.962. Conclusion: the validity and reliability of the FES-I Portugal are consistent with the original version and proved to be appropriate instruments for evaluating the “impaired walking” and “risk of falls” nursing diagnoses in the older people.

  9. Robotic thin layer chromatography instrument for synthetic chemistry

    International Nuclear Information System (INIS)

    Corkan, L.A.; Haynes, E.; Kline, S.; Lindsey, J.S.

    1991-01-01

    We have constructed a second generation instrument for performing automated thin layer chromatography (TLC), The TLC instrument Consists of four dedicated stations for (1) plate dispensing, (2) sample application, (3) plate development, and (4) densitometry. A robot is used to move TLC plates among stations. The TLC instrument functions either as a stand-alone unit or as one analytical module in a robotic workstation for synthetic chemistry. An integrated hardware and software architecture enables automatic TLC analysis of samples produced concurrently from synthetic reactions in progress on the workstation. The combination of fixed automation and robotics gives a throughput of 12 TLC samples per hour. From these results a blueprint has emerged for an advanced automated TLC instrument with far greater throughput and analytical capabilities

  10. Programming for a nuclear reactor instrument simulator

    International Nuclear Information System (INIS)

    Cohn, C.E.

    1989-01-01

    A new computerized control system for a transient test reactor incorporates a simulator for pre-operational testing of control programs. The part of the simulator pertinent to the discussion here consists of two microprocessors. An 8086/8087 reactor simulator calculates simulated reactor power by solving the reactor kinetics equations. An 8086 instrument simulator takes the most recent power value developed by the reactor simulator and simulates the appropriate reading on each of the eleven reactor instruments. Since the system is required to run on a one millisecond cycle, careful programming was required to take care of all eleven instruments in that short time. This note describes the special programming techniques used to attain the needed performance

  11. Absorption coefficient instrument for turbid natural waters

    Science.gov (United States)

    Friedman, E.; Cherdak, A.; Poole, L.; Houghton, W.

    1980-01-01

    The paper presents an instrument that directly measures multispectral absorption coefficient of turbid natural water. Attention is given to the design, which is shown to incorporate methods for the compensation of variation in the internal light source intensity, correction of the spectrally dependent nature of the optical elements, and correction for variation in the background light level. In addition, when used in conjunction with a spectrally matched total attenuation instrument, the spectrally dependent scattering coefficient can also be derived. Finally, it is reported that systematic errors associated with multiple scattering have been estimated using Monte Carlo techniques.

  12. Tablatures : Exposition photographique d'instruments virtuels GENESIS

    OpenAIRE

    Cadoz, Claude

    2012-01-01

    International audience; Le concept de « composer le son », introduit et expérimenté musicalement par Jean-Claude Risset à partir des années 1960 par la synthèse de sons par ordinateur, prolonge, élargit, dépasse et transforme l'acte d'écriture pour des instruments mécano-acoustiques. Il ne résout cependant pas la question de l'instrumentalité, particulièrement mise à mal avec l'ordinateur. Les technologies de modélisation et de simulation numériques pour « écrire l'instrument pour le composer...

  13. Quality assurance of radiation protection monitoring instruments in India

    International Nuclear Information System (INIS)

    Tripathi, S.M.; Daniel, Liji; Rao, Suresh; Sharma, D.N.

    2008-01-01

    Bhabha Atomic Research Centre (BARC) is the National Metrology Institute (NMI) for developing, maintaining and disseminating standards for ionizing radiation in India. Radiation Safety Systems Division (RSSD) of BARC has the requisite infrastructure in the form of experts, trained manpower, laboratories, equipment and facilities for providing calibration services to users and ascertaining traceability to international standards. It periodically participates in various international inter-comparisons. RSSD maintains reference radiation fields that are required for calibrating Radiation Protection Monitoring Instruments that form the backbone of the radiation monitoring programme for harnessing the benefits of nuclear energy and ionizing radiations. These instruments are type-tested and periodically calibrated at standard reference radiation fields to ensure their healthy working condition and fitness for their intended use. This paper describes the details of the standardization procedures adopted for reference radiation fields and infrastructure established and maintained at RSSD, BARC in accordance with the recommendations of ISO-4037. The paper describes the various tests that are carried out for radiation protection monitoring instrument to study the variation of the calibration factor with influencing quantities like linearity of response, energy response, angular dependence and overload characteristics. The results of these tests for typical instruments are also discussed. The present work also describes various types of indigenously developed radiation protection monitoring instruments and their performance characteristics. Adaptability of these instruments for the implementation of operational quantities are discussed briefly. It also dwells on the IAEA Quality Audit for radiation protection level calibrations, which RSSD has been participating since 2001. Our results of the quality audit are well within the acceptance limit (±7%) set by IAEA for the

  14. 26 CFR 31.3121(b)(5)-1 - Services in employ of an instrumentality of the United States specifically exempted from the...

    Science.gov (United States)

    2010-04-01

    ... Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) EMPLOYMENT TAXES AND... employ of an instrumentality of the United States specifically exempted from the employer tax. Services... 26 Internal Revenue 15 2010-04-01 2010-04-01 false Services in employ of an instrumentality of the...

  15. Is cosmology consistent?

    International Nuclear Information System (INIS)

    Wang Xiaomin; Tegmark, Max; Zaldarriaga, Matias

    2002-01-01

    We perform a detailed analysis of the latest cosmic microwave background (CMB) measurements (including BOOMERaNG, DASI, Maxima and CBI), both alone and jointly with other cosmological data sets involving, e.g., galaxy clustering and the Lyman Alpha Forest. We first address the question of whether the CMB data are internally consistent once calibration and beam uncertainties are taken into account, performing a series of statistical tests. With a few minor caveats, our answer is yes, and we compress all data into a single set of 24 bandpowers with associated covariance matrix and window functions. We then compute joint constraints on the 11 parameters of the 'standard' adiabatic inflationary cosmological model. Our best fit model passes a series of physical consistency checks and agrees with essentially all currently available cosmological data. In addition to sharp constraints on the cosmic matter budget in good agreement with those of the BOOMERaNG, DASI and Maxima teams, we obtain a heaviest neutrino mass range 0.04-4.2 eV and the sharpest constraints to date on gravity waves which (together with preference for a slight red-tilt) favor 'small-field' inflation models

  16. Career-Success Scale – A new instrument to assess young physicians' academic career steps

    Science.gov (United States)

    Buddeberg-Fischer, Barbara; Stamm, Martina; Buddeberg, Claus; Klaghofer, Richard

    2008-01-01

    Background Within the framework of a prospective cohort study of Swiss medical school graduates, a Career-Success Scale (CSS) was constructed in a sample of young physicians choosing different career paths in medicine. Furthermore the influence of personality factors, the participants' personal situation, and career related factors on their career success was investigated. Methods 406 residents were assessed in terms of career aspired to, and their career progress. The Career-Success Scale, consisting of 7 items, was developed and validated, addressing objective criteria of academic career advancement. The influence of gender and career aspiration was investigated by a two-factorial analysis of variance, the relationships between personality factors, personal situation, career related factors and the Career-Success Scale by a multivariate linear regression analysis. Results The unidimensional Career-Success Scale has an internal consistency of 0.76. It is significantly correlated at the bivariate level with gender, instrumentality, and all career related factors, particularly with academic career and received mentoring. In multiple regression, only gender, academic career, surgery as chosen specialty, and received mentoring are significant predictors. The highest values were observed in participants aspiring to an academic career, followed by those pursuing a hospital career and those wanting to run a private practice. Independent of the career aspired to, female residents have lower scores than their male colleagues. Conclusion The Career-Success Scale proved to be a short, reliable and valid instrument to measure career achievements. As mentoring is an independent predictor of career success, mentoring programs could be an important instrument to specifically enhance careers of female physicians in academia. PMID:18518972

  17. Career-Success Scale – A new instrument to assess young physicians' academic career steps

    Directory of Open Access Journals (Sweden)

    Buddeberg Claus

    2008-06-01

    Full Text Available Abstract Background Within the framework of a prospective cohort study of Swiss medical school graduates, a Career-Success Scale (CSS was constructed in a sample of young physicians choosing different career paths in medicine. Furthermore the influence of personality factors, the participants' personal situation, and career related factors on their career success was investigated. Methods 406 residents were assessed in terms of career aspired to, and their career progress. The Career-Success Scale, consisting of 7 items, was developed and validated, addressing objective criteria of academic career advancement. The influence of gender and career aspiration was investigated by a two-factorial analysis of variance, the relationships between personality factors, personal situation, career related factors and the Career-Success Scale by a multivariate linear regression analysis. Results The unidimensional Career-Success Scale has an internal consistency of 0.76. It is significantly correlated at the bivariate level with gender, instrumentality, and all career related factors, particularly with academic career and received mentoring. In multiple regression, only gender, academic career, surgery as chosen specialty, and received mentoring are significant predictors. The highest values were observed in participants aspiring to an academic career, followed by those pursuing a hospital career and those wanting to run a private practice. Independent of the career aspired to, female residents have lower scores than their male colleagues. Conclusion The Career-Success Scale proved to be a short, reliable and valid instrument to measure career achievements. As mentoring is an independent predictor of career success, mentoring programs could be an important instrument to specifically enhance careers of female physicians in academia.

  18. Internally consistent thermodynamic data for aqueous species in the system Na-K-Al-Si-O-H-Cl

    Science.gov (United States)

    Miron, George D.; Wagner, Thomas; Kulik, Dmitrii A.; Heinrich, Christoph A.

    2016-08-01

    A large amount of critically evaluated experimental data on mineral solubility, covering the entire Na-K-Al-Si-O-H-Cl system over wide ranges in temperature and pressure, was used to simultaneously refine the standard state Gibbs energies of aqueous ions and complexes in the framework of the revised Helgeson-Kirkham-Flowers equation of state. The thermodynamic properties of the solubility-controlling minerals were adopted from the internally consistent dataset of Holland and Powell (2002; Thermocalc dataset ds55). The global optimization of Gibbs energies of aqueous species, performed with the GEMSFITS code (Miron et al., 2015), was set up in such a way that the association equilibria for ion pairs and complexes, independently derived from conductance and potentiometric data, are always maintained. This was achieved by introducing reaction constraints into the parameter optimization that adjust Gibbs energies of complexes by their respective Gibbs energy effects of reaction, whenever the Gibbs energies of reactant species (ions) are changed. The optimized thermodynamic dataset is reported with confidence intervals for all parameters evaluated by Monte Carlo trial calculations. The new thermodynamic dataset is shown to reproduce all available fluid-mineral phase equilibria and mineral solubility data with good accuracy and precision over wide ranges in temperature (25-800 °C), pressure (1 bar to 5 kbar) and composition (salt concentrations up to 5 molal). The global data optimization process adopted in this study can be readily repeated any time when extensions to new chemical elements and species are needed, when new experimental data become available, or when a different aqueous activity model or equation of state should be used. This work serves as a proof of concept that our optimization strategy is feasible and successful in generating a thermodynamic dataset reproducing all fluid-mineral and aqueous speciation equilibria in the Na-K-Al-Si-O-H-Cl system within

  19. ICFA Instrumentation Bulletin, Volume 24, Spring 2002 Issue (SLAC-J-ICFA-024)

    Energy Technology Data Exchange (ETDEWEB)

    Va' Vra, J.

    2003-10-21

    The publication of the ICFA Instrumentation Bulletin is an activity of the Panel on Future Innovation and Development of ICFA (International Committee for Future Accelerators). The Bulletin reports on research and progress in the field of instrumentation with emphasis on application in the field of high-energy physics. It encourages issues of generic instrumentation. This volume covers the following articles: (1) ''Physics and Chemistry of Aging--Early Developments; (2) ''Summary and Outlook of the International Workshop on Aging Phenomena in Gaseous Detectors (DESY, Hamburg, October 2001)''; (3) ''Studies of Aging and High Voltage Break Down Problems during Development and Operation of MSGC and GEM Detectors for the Inner Tracking System of HERA-B''; and (4) ''Aging of Gaseous Detectors: Assembly Materials and Procedures.

  20. Using XML and Java for Astronomical Instrumentation Control

    Science.gov (United States)

    Ames, Troy; Koons, Lisa; Sall, Ken; Warsaw, Craig

    2000-01-01

    Traditionally, instrument command and control systems have been highly specialized, consisting mostly of custom code that is difficult to develop, maintain, and extend. Such solutions are initially very costly and are inflexible to subsequent engineering change requests, increasing software maintenance costs. Instrument description is too tightly coupled with details of implementation. NASA Goddard Space Flight Center is developing a general and highly extensible framework that applies to any kind of instrument that can be controlled by a computer. The software architecture combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML), a human readable and machine understandable way to describe structured data. A key aspect of the object-oriented architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). ]ML is used to describe graphical user interfaces to control and monitor the instrument, command sets and command formats, data streams, and communication mechanisms. Although the current effort is targeted for the High-resolution Airborne Wideband Camera, a first-light instrument of the Stratospheric Observatory for Infrared Astronomy, the framework is designed to be generic and extensible so that it can be applied to any instrument.

  1. Malaysian Preparation for Nuclear Power Plant Instrumentation and Control System

    International Nuclear Information System (INIS)

    Mohd Idris Taib; Nurfarhana Ayuni Joha; Kamarudin Sulaiman; Izhar Abu Hussin

    2011-01-01

    Instrumentation and Control System is required in Nuclear Power Plant for their safe and effective operation. The system is combination and integrated from detectors, actuators, analog system as well as digital system. Current design of system definitely follows of electronic as well as computer technology, with strictly follow regulation and guideline from local regulator as well as International Atomic Energy Agency. Commercial Off-The-Shelf products are extensively used with specific nucleonic instrumentation. Malaysian experiences depend on Reactor TRIGA PUSPATI Instrumentation and Control, Power Plant Instrumentation and Control as well as Process Control System. However Malaysians have capabilities to upgrade themself from Electronics, Computers, Electrical and Mechanical based. Proposal is presented for Malaysian preparation. (author)

  2. QUOTE-gene(ca): development of a counselee-centered instrument to measure needs and preferences in genetic counseling for hereditary cancer.

    Science.gov (United States)

    Pieterse, Arwen; van Dulmen, Sandra; Ausems, Margreet; Schoemaker, Angela; Beemer, Frits; Bensing, Jozien

    2005-05-01

    Counselees' motives for seeking genetic counseling for hereditary cancer have already been investigated, however not using instruments based on counselees' perspective. In addition, expectations regarding the process of counseling have scarcely been assessed. This article describes the construction and psychometric properties of the QUOTE-gene(ca), a counselee-centered instrument intended to measure needs and preferences in genetic counseling for hereditary cancer. Formulation of the items involved input from counselees and the instrument was derived from a conceptual framework for measuring patient satisfaction. Two-hundred new counselees completed a questionnaire containing the instrument and measures of coping style (TMSI), generalized anxiety (STAI) and cancer-related stress reactions (IES), prior to their first consultation. Results showed that the instrument captures relevant issues of concern with high internal consistency, and was associated, as expected, with validated measures of coping style and distress. Responses showed that major concerns prior to counseling relate to: receiving information about risk and preventive strategies; the procedure of counseling; and preferences on how the interaction with the counselor proceeds. Receiving emotional support and discussing emotional aspects were considered relatively less important. Increasing insight into individual needs may help counselors in better addressing these concerns, potentially increasing the likelihood of successful counseling. Copyright (c) 2004 John Wiley & Sons, Ltd.

  3. Development and Validation of an Instrument Measuring Theory-Based Determinants of Monitoring Obesogenic Behaviors of Pre-Schoolers among Hispanic Mothers

    Directory of Open Access Journals (Sweden)

    Paul Branscum

    2016-06-01

    Full Text Available Public health interventions are greatly needed for obesity prevention, and planning for such strategies should include community participation. The study’s purpose was to develop and validate a theory-based instrument with low-income, Hispanic mothers of preschoolers, to assess theory-based determinants of maternal monitoring of child’s consumption of fruits and vegetables and sugar-sweetened beverages (SSB. Nine focus groups with mothers were conducted to determine nutrition-related behaviors that mothers found as most obesogenic for their children. Next, behaviors were operationally defined and rated for importance and changeability. Two behaviors were selected for investigation (fruits and vegetable and SSB. Twenty semi-structured interviews with mothers were conducted next to develop culturally appropriate items for the instrument. Afterwards, face and content validity were established using a panel of six experts. Finally, the instrument was tested with a sample of 238 mothers. Psychometric properties evaluated included construct validity (using the maximum likelihood extraction method of factor analysis, and internal consistency reliability (Cronbach’s alpha. Results suggested that all scales on the instrument were valid and reliable, except for the autonomy scales. Researchers and community planners working with Hispanic families can use this instrument to measure theory-based determinants of parenting behaviors related to preschoolers’ consumption of fruits and vegetables, and SSB.

  4. The development and validation of the speech quality instrument.

    Science.gov (United States)

    Chen, Stephanie Y; Griffin, Brianna M; Mancuso, Dean; Shiau, Stephanie; DiMattia, Michelle; Cellum, Ilana; Harvey Boyd, Kelly; Prevoteau, Charlotte; Kohlberg, Gavriel D; Spitzer, Jaclyn B; Lalwani, Anil K

    2017-12-08

    Although speech perception tests are available to evaluate hearing, there is no standardized validated tool to quantify speech quality. The objective of this study is to develop a validated tool to measure quality of speech heard. Prospective instrument validation study of 35 normal hearing adults recruited at a tertiary referral center. Participants listened to 44 speech clips of male/female voices reciting the Rainbow Passage. Speech clips included original and manipulated excerpts capturing goal qualities such as mechanical and garbled. Listeners rated clips on a 10-point visual analog scale (VAS) of 18 characteristics (e.g. cartoonish, garbled). Skewed distribution analysis identified mean ratings in the upper and lower 2-point limits of the VAS (ratings of 8-10, 0-2, respectively); items with inconsistent responses were eliminated. The test was pruned to a final instrument of nine speech clips that clearly define qualities of interest: speech-like, male/female, cartoonish, echo-y, garbled, tinny, mechanical, rough, breathy, soothing, hoarse, like, pleasant, natural. Mean ratings were highest for original female clips (8.8) and lowest for not-speech manipulation (2.1). Factor analysis identified two subsets of characteristics: internal consistency demonstrated Cronbach's alpha of 0.95 and 0.82 per subset. Test-retest reliability of total scores was high, with an intraclass correlation coefficient of 0.76. The Speech Quality Instrument (SQI) is a concise, valid tool for assessing speech quality as an indicator for hearing performance. SQI may be a valuable outcome measure for cochlear implant recipients who, despite achieving excellent speech perception, often experience poor speech quality. 2b. Laryngoscope, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  5. How Affectively-Based and Cognitively-Based Attitudes Drive Intergroup Behaviours: The Moderating Role of Affective-Cognitive Consistency

    Science.gov (United States)

    Zhou, Jie; Dovidio, John; Wang, Erping

    2013-01-01

    The moderating role of affective-cognitive consistency in the effects of affectively-based and cognitively-based attitudes on consummatory and instrumental behaviors was explored using two experimental studies in the intergroup context. Study 1 revealed that affectively-based attitudes were better predictors than cognitively-based attitudes regardless of affective-cognitive consistency for consummatory behaviors (e.g., undergraduates’ supportive behaviors toward government officials). Study 2, which investigated task groups’ supportive behaviors toward an immediate supervisory group, found that for these instrumental behaviors cognitively-based attitudes were better predictors than affectively-based attitudes only when affective-cognitive consistency was high. The present research also examined the mechanism by which affective-cognitive consistency moderates the relative roles of affectively-based and cognitively-based attitudes in attitude-behavior consistency. Results indicated that attitude-behavior consistency is eroded primarily because of the weaker relationship of affective or cognitive components to behaviors than to general attitudes. The reciprocal implications of research on attitudes and work on intergroup relations are considered. PMID:24244751

  6. [Psychometric properties of an instrument to evaluate the nurse attitude towards good practice guides].

    Science.gov (United States)

    López-Díaz, Cristina; Fraille-Calle, Luis; Herrero-Rosado, Marta; Arnés-Muñoz, Vanessa; De-Dios-De-Dios, Teresa

    2016-01-01

    The Guides of Good Practices (GGP) are necessary tools in the universal healthcare and in the clinical management, providing the user/patient with a major quality in the assistance, in order to optimize and reinforce an individualized attention into action, taking into account the best scientific evidence. The literature provides different references to the development of the GGP, but there is little knowledge about the attitude of professionals towards them, since most of the studies that exist are qualitative. Therefore, the aim of this work is to construct and validate a Likert scale which could assess the attitude of the nurse towards GGP. The methodology used was quantitative, descriptive, cross, opinion, anonymous and also it could validate a scale via the following measurements: content validation by experts, correlation between items, external reliability, internal consistency, stability and exploratory factor analysis. The result was a scale consisting of 20 items that refer to the attitude toward the GGP, with a percentage of agreement among experts over 75 % on all the items, and a significant Pearson correlation between the pre-test and post-test in all variables, but for three. The internal consistency measured by Cronbach's alpha was 0.878. These results are acceptable in terms of the psychometric characteristics of the instrument, with easy and fast administration and simple in their interpretation, allowing quantifying and generating knowledge about the attitudes of nurses towards GGP.

  7. 26 CFR 301.6222(a)-1 - Consistent treatment of partnership items.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 18 2010-04-01 2010-04-01 false Consistent treatment of partnership items. 301... Consistent treatment of partnership items. (a) In general. The treatment of a partnership item on the partner's return must be consistent with the treatment of that item by the partnership on the partnership...

  8. Test-Retest Reliability, Convergent Validity, and Internal Consistency of the Persian Version of Fullerton Advanced Balance Scale in Iranian Community-Dwelling Older Adults

    OpenAIRE

    Azar Sabet; Akram Azad; Ghorban Taghizadeh

    2016-01-01

    Objectives: This study was performed to evaluate convergent validity, test-retest reliability and internal consistency of the Persian translation of the Fullerton advanced balance (FAB) for use in Iranian community- dwelling older adults and improve the quality of their functional balance assessment. Methods & Materials: The original scale was translated with forward-backward protocol. In the next step, using convenience sampling and inclusion criteria, 88 functionally indep...

  9. A Workshop on Methods for Neutron Scattering Instrument Design. Introduction and Summary

    International Nuclear Information System (INIS)

    Hjelm, Rex P.

    1996-09-01

    The future of neutron and x-ray scattering instrument development and international cooperation was the focus of the workshop on ''Methods for Neutron Scattering Instrument Design'' September 23-25 at the E.O. Lawrence Berkeley National Laboratory. These proceedings are a collection of a portion of the invited and contributed presentations

  10. TFTR CAMAC instrumentation system

    International Nuclear Information System (INIS)

    Del Gatto, H.J.; Bradish, C.J.

    1983-01-01

    The TFTR Central Instrumentation Control and Data Acquisition (CICADA) system makes extensive use of CAMAC equipment. The system consists of eight CAMAC highways operating from eight Gould 75/32 computers. Links up to 3.5 miles in length with more than fifty CAMAC crates have been implemented and are currently in use. Data transfer along the highway is implemented in bit serial format. The link speed is run at 5MHz. The length and complexity of the link requires the reformatting of the NRZ input/output format of the L-2 crate controller. U-Port adapter modules are used to interface the modified serial highway to the L-2 controllers. The modified serial highway uses a transmission technique that requires the distribution of both Bi-Phase encoded data and a 5MHz clock. The Serial Driver interfaces to the GOULD computer through use of a High Speed Data (HSD) interface board which attaches to the computers internal bus. All transfers to and from the computer are accomplished by direct memory access (DMA). In addition to the standard CAMAC link the system also includes a Block Transfer (BT) system. This system provides an alternate path for transferring data between the computers and the CAMAC modules. The BT system is interfaced to the host computers through HSD boards and to the CAMAC crates through use of an auxiliary crate controllers

  11. Internal budget control

    OpenAIRE

    MSc. Mervete Shala

    2011-01-01

    Internal control is established by the Government to ensure effective and proper operations of ministries, institutions and generally of all public agencies, in compliance with the law, the goals and objectives stated by them, to provide protection against abuse and mismanagement or poor governance. The instrument of internal audit entails a series of mechanisms which aim at enabling budgetary policies compliance, such as: financial reporting; effective system of communication between mana...

  12. A hierarchical instrumental decision theory of nicotine dependence.

    Science.gov (United States)

    Hogarth, Lee; Troisi, Joseph R

    2015-01-01

    It is important to characterize the learning processes governing tobacco-seeking in order to understand how best to treat this behavior. Most drug learning theories have adopted a Pavlovian framework wherein the conditioned response is the main motivational process. We favor instead a hierarchical instrumental decision account, wherein expectations about the instrumental contingency between voluntary tobacco-seeking and the receipt of nicotine reward determines the probability of executing this behavior. To support this view, we review titration and nicotine discrimination research showing that internal signals for deprivation/satiation modulate expectations about the current incentive value of smoking, thereby modulating the propensity of this behavior. We also review research on cue-reactivity which has shown that external smoking cues modulate expectations about the probability of the tobacco-seeking response being effective, thereby modulating the propensity of this behavior. Economic decision theory is then considered to elucidate how expectations about the value and probability of response-nicotine contingency are integrated to form an overall utility estimate for that option for comparison with qualitatively different, nonsubstitute reinforcers, to determine response selection. As an applied test for this hierarchical instrumental decision framework, we consider how well it accounts for individual liability to smoking uptake and perseveration, pharmacotherapy, cue-extinction therapies, and plain packaging. We conclude that the hierarchical instrumental account is successful in reconciling this broad range of phenomenon precisely because it accepts that multiple diverse sources of internal and external information must be integrated to shape the decision to smoke.

  13. Developing the health, safety and environment excellence instrument.

    Science.gov (United States)

    Mohammadfam, Iraj; Saraji, Gebraeil Nasl; Kianfar, Ali; Mahmoudi, Shahram

    2013-01-07

    Quality and efficiency are important issues in management systems. To increase quality, to reach best results, to move towards the continuous improvement of system and also to make the internal and external customers satisfied, it is necessary to consider the system performance measurement. In this study the Health, Safety and Environment Excellence Instrument was represented as a performance measurement tool for a wide range of health, safety and environment management systems. In this article the development of the instrument overall structure, its parts, and its test results in three organizations are presented. According to the results, the scores ranking was the managership organization, the manufacturing company and the powerhouse construction project, respectively. The results of the instrument test in three organizations show that, on the whole, the instrument has the ability to measure the performance of health, safety and environment management systems in a wide range of organizations.

  14. Measurement properties of quality-of-life measurement instruments for infants, children and adolescents with eczema: a systematic review.

    Science.gov (United States)

    Heinl, D; Prinsen, C A C; Sach, T; Drucker, A M; Ofenloch, R; Flohr, C; Apfelbacher, C

    2017-04-01

    Quality of life (QoL) is one of the core outcome domains identified by the Harmonising Outcome Measures for Eczema (HOME) initiative to be assessed in every eczema trial. There is uncertainty about the most appropriate QoL instrument to measure this domain in infants, children and adolescents. To systematically evaluate the measurement properties of existing measurement instruments developed and/or validated for the measurement of QoL in infants, children and adolescents with eczema. A systematic literature search in PubMed and Embase, complemented by a thorough hand search of reference lists, retrieved studies on measurement properties of eczema QoL instruments for infants, children and adolescents. For all eligible studies, we judged the adequacy of the measurement properties and the methodological study quality with the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist. Results from different studies were summarized in a best-evidence synthesis and formed the basis to assign four degrees of recommendation. Seventeen articles, three of which were found by hand search, were included. These 17 articles reported on 24 instruments. No instrument can be recommended for use in all eczema trials because none fulfilled all required adequacy criteria. With adequate internal consistency, reliability and hypothesis testing, the U.S. version of the Childhood Atopic Dermatitis Impact Scale (CADIS), a proxy-reported instrument, has the potential to be recommended depending on the results of further validation studies. All other instruments, including all self-reported ones, lacked significant validation data. Currently, no QoL instrument for infants, children and adolescents with eczema can be highly recommended. Future validation research should primarily focus on the CADIS, but also attempt to broaden the evidence base for the validity of self-reported instruments. © 2016 British Association of Dermatologists.

  15. Determination of trace elements in fisheries samples by instrumental neutron and photon activation analysis

    International Nuclear Information System (INIS)

    Chattopadhyay, A.; Ellis, K.M.; Nimalasiri Desilva, K.

    1979-01-01

    An instrumental neutron activation analysis (INAA) method has been developed for the simultaneous determination of trace concentrations of up to 23 elements in fisheries samples. The INAA method consists of irradiations of wet and lyophilized cod muscle and liver samples for three different periods at a flux density of 5x10 11 n.cm -2 .s -1 and subsequent measurements after four different decay periods using high-resolution Ge(Li) gamma-ray spectrometry. Concentrations of several essential and toxic elements have been determined. Loss of certain elements during lyophilization has been studied. Elemental distribution in muscles and livers as a function of the age of fish has been investigated. Precision and accuracy of the INAA method have been evaluated by analysing replicate samples, National Bureau of Standards' bovine liver standard reference material, and an intercalibration fish flour sample provided by the International Council for the Exploration of the Sea. A few fish samples have also been analysed by an alternative method, namely instrumental photon activation analysis (IPAA). Elemental concentrations determined by both INAA and IPAA methods are reported here. (author)

  16. International Atomic Energy Agency specialists meeting on experience in ageing, maintenance, and modernization of instrumentation and control systems for improving nuclear power plant availability

    Energy Technology Data Exchange (ETDEWEB)

    1993-10-01

    This report presents the proceedings of the Specialist`s Meeting on Experience in Aging, Maintenance and Modernization of Instrumentation and Control Systems for Improving Nuclear Power Plant Availability that was held at the Ramada Inn in Rockville, Maryland on May 5--7, 1993. The Meeting was presented in cooperation with the Electric Power Research Institute, Oak Ridge National Laboratory and the International Atomic Energy Agency. There were approximately 65 participants from 13 countries at the Meeting. Individual reports have been cataloged separately.

  17. International Atomic Energy Agency specialists meeting on experience in ageing, maintenance, and modernization of instrumentation and control systems for improving nuclear power plant availability

    International Nuclear Information System (INIS)

    1993-10-01

    This report presents the proceedings of the Specialist's Meeting on Experience in Aging, Maintenance and Modernization of Instrumentation and Control Systems for Improving Nuclear Power Plant Availability that was held at the Ramada Inn in Rockville, Maryland on May 5--7, 1993. The Meeting was presented in cooperation with the Electric Power Research Institute, Oak Ridge National Laboratory and the International Atomic Energy Agency. There were approximately 65 participants from 13 countries at the Meeting. Individual reports have been cataloged separately

  18. Nuclear electronic instrumentation

    International Nuclear Information System (INIS)

    Ramirez J, F. J.

    2010-01-01

    The activities carried out in the Instituto Nacional de Investigaciones Nucleares (ININ) in the field of the nuclear electronic instrumentation included those activities corresponding to the design and production of nuclear instruments in a first stage, as well as the internal activities of design, repair and maintenance that have supported to other projects of the institution during many years. It is mentioned of the presence and constant collaboration of the ININ with the IAEA in different projects and programs. Also, it is mentioned on the establishment of the Radiation Detectors Laboratory, which for their characteristics and repair capacities of radiation detectors of cooled semiconductor, it is only in their specialty. It is emphasized the investigation and the development in the field of new radiation detectors and applications, as well as the important contribution in this field, in institutions like: Mexican Petroleum, National Commission of Nuclear Safety and Safeguards and Federal Commission of Electricity. Finally a position of the future of these activities is made, considering the speed of the advances of the electronic and nuclear technology. (Author)

  19. The commissioning instrument for the Gran Telescopio Canarias: made in Mexico

    Science.gov (United States)

    Cuevas, Salvador; Sánchez, Beatriz; Bringas, Vicente; Espejo, Carlos; Flores, Rubén; Chapa, Oscar; Lara, Gerardo; Chavoya, Armando; Anguiano, Gustavo; Arciniega, Sadot; Dorantes, Ariel; Gonzalez, José L.; Montoya, Juan M.; Toral, Rafael; Hernández, Hugo; Nava, Roberto; Devaney, Nicolas; Castro, Javier; Cavaller, Luis; Farah, Alejandro; Godoy, Javier; Cobos, Francisco; Tejada, Carlos; Garfias, Fernando

    2006-02-01

    In March 2004 was accepted in the site of Gran Telescopio Canarias (GTC) in La Palma Island, Spain, the Commissioning Instrument (CI) for the GTC. During the GTC integration phase, the CI will be a diagnostic tool for performance verification. The CI features four operation modes-imaging, pupil imaging, Curvature Wave-front sensing (WFS), and high resolution Shack-Hartmann WFS. This instrument was built by the Instituto de Astronomia UNAM in Mexico City and the Centro de Ingenieria y Desarrollo Industrial (CIDESI) in Queretaro, Qro under a GRANTECAN contract after an international public bid. Some optical components were built by Centro de Investigaciones en Optica (CIO) in Leon Gto and the biggest mechanical parts were manufactured by Vatech in Morelia Mich. In this paper we made a general description of the CI and we relate how this instrument, build under international standards, was entirely made in Mexico.

  20. Status of ART-XC/SRG Instrument

    Science.gov (United States)

    Pavlinsky, M.; Akimov, V.; Levin, V.; Lapshov, I.; Tkachenko, A.; Semena, N.; Buntov, M.; Glushenko, A.; Arefiev, V.; Yaskovich, A.; hide

    2014-01-01

    Spectrum Roentgen Gamma (SRG) is an X-ray astrophysical observatory, developed by Russia in collaboration with Germany. The mission will be launched in March 2016 from Baikonur, by a Zenit rocket with a Fregat booster and placed in a 6-month-period halo orbit around L2. The scientific payload consists of two independent telescopes - a soft-x-ray survey instrument, eROSITA, being provided by Germany and a medium-x-ray-energy survey instrument ART-XC being developed by Russia. ART-XC will consist of seven independent, but co-aligned, telescope modules. The NASA Marshall Space Flight Center (MSFC) is fabricating the flight mirror modules for the ART-XC/SRG. Each mirror module will be aligned with a focal plane CdTe double-sided strip detectors which will operate over the energy range of 6-30 keV, with an angular resolution of less than 1', a field of view of approximately 34' and an expected energy resolution of about 10 percent at 14 keV.

  1. Instrumental nuclear physics: elements for a proper choice

    International Nuclear Information System (INIS)

    1994-01-01

    This report consists of 11 documents about instrumental nuclear physics. It describes several detectors and data analysis techniques. Separate abstracts were prepared for all the papers in this volume. (TEC)

  2. The design of a simple radon-detecting instrument based on MCU

    International Nuclear Information System (INIS)

    Du Genyuan; Qiu Yingyu; Zhang Jiang

    2007-01-01

    Introduction are given on the internal composition of the radon-detecting instrument based on MCU and the working of the real electric circuit. The single-chip microcomputer P89C58 of PHILIPS is adopted as the micro-controller of the instrument, realizing such functions as counting input pulses within fixed time, data processing, liquid crystal display, keyboard interface, serial communication, etc. The instrument turns out to be low in work consumption, with relatively high degree of concentration and computerization, and is recommended for field operations. (authors)

  3. The design of a simple radon-detecting instrument based on MCU

    International Nuclear Information System (INIS)

    Du Genyuan; Chen Jianjun; Zhang Jiang

    2008-01-01

    Introduction are given on the internal composition of the radon-detecting instrument based on MCU and the working of the real electric circuit. The single-chip microcomputer P89C58 of PHILIPS is adopted as the micro-controller of the instrument, realizing such functions as counting input pulses within fixed time, data processing, liquid crystal display, keyboard interface, serial communication, etc. The instrument turns out to be low in work consumption, with relatively high degree of concentration and computerization, and is recommended for field operations. (authors)

  4. Scientific instruments, scientific progress and the cyclotron

    International Nuclear Information System (INIS)

    Baird, David; Faust, Thomas

    1990-01-01

    Philosophers speak of science in terms of theory and experiment, yet when they speak of the progress of scientific knowledge they speak in terms of theory alone. In this article it is claimed that scientific knowledge consists of, among other things, scientific instruments and instrumental techniques and not simply of some kind of justified beliefs. It is argued that one aspect of scientific progress can be characterized relatively straightforwardly - the accumulation of new scientific instruments. The development of the cyclotron is taken to illustrate this point. Eight different activities which promoted the successful completion of the cyclotron are recognised. The importance is in the machine rather than the experiments which could be run on it and the focus is on how the cyclotron came into being, not how it was subsequently used. The completed instrument is seen as a useful unit of scientific progress in its own right. (UK)

  5. Risk exposure mitigation: Approaches and recognised instruments (5

    Directory of Open Access Journals (Sweden)

    Matić Vesna

    2014-01-01

    Full Text Available The risk management function development in banks, along with the development of tools that banks can use throughout this process, has had the strong support in international standards, not only in the recommended approaches for calculating economic capital requirements, but also in the qualitatively new treatment of risk exposure mitigation instruments (Basel Accord II. The array of eligible instruments for exposure mitigation under the recommended approaches for their treatment becomes the essential element of economic capital requirements calculation, both in relation to certain types of risk, and in relation to aggregate exposure.

  6. Risk exposure mitigation: Approaches and recognised instruments (3

    Directory of Open Access Journals (Sweden)

    Matić Vesna

    2014-01-01

    Full Text Available The risk management function development in banks, along with the development of tools that banks can use throughout this process, has had the strong support in international standards, not only in the recommended approaches for calculating economic capital requirements, but also in the qualitatively new treatment of risk exposure mitigation instruments (Basel Accord II. The array of eligible instruments for exposure mitigation under the recommended approaches for their treatment becomes the essential element of economic capital requirements calculation, both in relation to certain types of risk, and in relation to aggregate exposure.

  7. Risk exposure mitigation: Approaches and recognised instruments (6

    Directory of Open Access Journals (Sweden)

    Matić Vesna

    2015-01-01

    Full Text Available The risk management function development in banks, along with the development of tools that banks can use throughout this process, has had the strong support in international standards, not only in the recommended approaches for calculating economic capital requirements, but also in the qualitatively new treatment of risk exposure mitigation instruments (Basel Accord II. The array of eligible instruments for exposure mitigation under the recommended approaches for their treatment becomes the essential element of economic capital requirements calculation, both in relation to certain types of risk, and in relation to aggregate exposure.

  8. The International Legal Framework for Nuclear Security

    International Nuclear Information System (INIS)

    2011-01-01

    The term 'nuclear security' is generally accepted to mean 'the prevention and detection of, and response to, theft, sabotage, unauthorized access, illegal transfer or other malicious acts involving nuclear material, other radioactive substances or their associated facilities.' While the ultimate responsibility for nuclear security within a State rests entirely with that State, the need for regional and international cooperation has become increasingly evident with the growing recognition that the ability to prevent, detect and respond to the threats to nuclear security within one State is affected by the adequacy and effectiveness of nuclear security measures taken by other States, particularly when nuclear material is transported across national frontiers. Since the early 1970s, the IAEA has been called upon to play an ever increasing role in assisting States, upon request, to strengthen their national legal infrastructures and physical protection systems, as well as to facilitate regional and international efforts to enhance nuclear security, including measures to protect against nuclear terrorism. This publication brings together the legally binding primary international instruments and the internationally accepted non-binding instruments that constitute the international legal framework for nuclear security. It does not discuss the safety and safeguards related instruments, which also form a part of the broader legal framework for nuclear security. By setting out the legislative bases for the mandate of the IAEA in the area of nuclear security, it is hoped that this publication will increase awareness of the IAEA's role in facilitating national, regional and international efforts to enhance nuclear security , including measures to protect against nuclear terrorism. It is also intended to serve as a guide in carrying out the IAEA's nuclear security mandate and functions assigned to it under these instruments, including in the elaboration of nuclear security

  9. Corruption as a 'white-collar crime': International legal instruments on public accountability of public officials

    Directory of Open Access Journals (Sweden)

    Dokmanović Mirjana

    2009-01-01

    Full Text Available Corruption within public services has devastated negative impact on a state, a society, its economy and its citizens. It represents a major threat to the rule of law, democracy, enjoyment of human rights, fairness and social justice. It hinders economic development and endangeres sustainable development, empowerishes national economies, and facilitates the emergence of other threats, such as organized crime. Fighting corruption has become more urgent than ever. This paper deals with the public liability of domestic public officials, highlighting the substantive main international standards for fighting corruption in public services in the international legal instruments adopted by the United Nations and the Council of Europe, such as the United Nations Conventions against Corruption, and the two Convention of Council of Europe, on Civil Law and on Criminal Law. The paper argues that corruption can be prosecuted after the fact, but first and foremost it requires prevention. Preventive policies include the establishment of anti-corruption bodies and enhanced transparency in the financing of election campaigns and political parties. States must endeavour to ensure that their public services are subject to safeguards that promote efficiency, transparency and recruitment based on merit. Once recruited, public servants should be subject to codes of conduct, requirements for financial and other disclosures, and appropriate disciplinary measures. Transparency and accountability in matters of public finance must also be promoted, and specific requirements are established for the prevention of corruption in particularly critical areas of the public sector such as the judiciary and public procurement. Those who use public services must expect a high standard of conduct from their public servants. Preventing public corruption also requires an effort from all members of society at large.

  10. Measuring participants' immersion in healthcare simulation: the development of an instrument.

    Science.gov (United States)

    Hagiwara, Magnus Andersson; Backlund, Per; Söderholm, Hanna Maurin; Lundberg, Lars; Lebram, Mikael; Engström, Henrik

    2016-01-01

    Immersion is important for simulation-based education; however, questionnaire-based instruments to measure immersion have some limitations. The aim of the present work is to develop a new instrument to measure immersion among participants in healthcare simulation scenarios. The instrument was developed in four phases: trigger identification, content validity scores, inter-rater reliability analysis and comparison with an existing immersion measure instrument. A modified Delphi process was used to develop the instrument and to establish validity and reliability. The expert panel consisted of 10 researchers. All the researchers in the team had previous experience of simulation in the health and/or fire and rescue services as researchers and/or educators and simulation designers. To identify triggers, the panel members independently screened video recordings from simulation scenarios. Here, a trigger is an event in a simulation that is considered a sign of reduced or enhanced immersion among simulation participants. The result consists of the Immersion Score Rating Instrument (ISRI). It contains 10 triggers, of which seven indicate reduced and three enhanced immersion. When using ISRI, a rater identifies trigger occurrences and assigns them strength between 1 and 3. The content validity analysis shows that all the 10 triggers meet an acceptable content validity index for items (I-CVI) standard. The inter-rater reliability (IRR) among raters was assessed using a two-way mixed, consistency, average-measures intra-class correlation (ICC). The ICC for the difference between weighted positive and negative triggers was 0.92, which indicates that the raters are in agreement. Comparison with results from an immersion questionnaire mirrors the ISRI results. In conclusion, we present a novel and non-intrusive instrument for identifying and rating the level of immersion among participants in healthcare simulation scenarios.

  11. Intergovernmental organisation activities: European Atomic Energy Community, International Atomic Energy Agency, OECD Nuclear Energy Agency

    International Nuclear Information System (INIS)

    Anon.

    2012-01-01

    European Atomic Energy Community: Proposed legislative instruments, Adopted legislative instruments, Non-legislative instruments, Other activities (meetings). International Atomic Energy Agency: IAEA Action Plan on Nuclear Safety. OECD Nuclear Energy Agency: The Russian Federation to join the OECD Nuclear Energy Agency; Participation by the regulatory authorities of India and the United Arab Emirates in the Multinational Design Evaluation Programme (MDEP); NEA International Workshop on Crisis Communication, 9-10 May 2012; International School of Nuclear Law: 2013; Next NEA International Nuclear Law Essentials Course

  12. Instrument for measuring fuel cladding strain

    International Nuclear Information System (INIS)

    Billeter, T.R.

    1976-01-01

    Development work to provide instrumentation for the continuous measurement of strain of material specimens such as nuclear fuel cladding has shown that a microwave sensor and associated instrumentation hold promise. The cylindrical sensor body enclosing the specimen results in a coaxial resonator absorbing microwave energy at frequencies dependent upon the diameter of the specimen. Diametral changes of a microinch can be resolved with use of the instrumentation. Very reasonable values of elastic strain were measured at 75 0 F and 1000 0 F for an internally pressurized 20 percent C.W. 316 stainless steel specimen simulating nuclear fuel cladding. The instrument also indicated the creep strain of the same specimen pressurized at 6500 psi and at a temperature of 1000 0 F for a period of 700 hours. Although the indicated strain appears greater than actual, the sensor/specimen unit experienced considerable oxidation even though an inert gas purge persisted throughout the test duration. By monitoring at least two modes of resonance, the measured strain was shown to be nearly independent of sensor temperature. To prevent oxidation, a second test was performed in which the specimen/sensor units were contained in an evacuated enclosure. The strain of the two prepressurized specimens as indicated by the microwave instrumentation agreed very closely with pre- and post-test measurements obtained with use of a laser interferometer

  13. Satisfaction and adherence in patients with iron overload receiving iron chelation therapy as assessed by a newly developed patient instrument.

    Science.gov (United States)

    Rofail, Diana; Abetz, Linda; Viala, Muriel; Gait, Claire; Baladi, Jean-Francois; Payne, Krista

    2009-01-01

    This study assesses satisfaction with iron chelation therapy (ICT) based on a reliable and valid instrument, and explores the relationship between satisfaction and adherence to ICT. Patients in the USA and UK completed a new "Satisfaction with ICT" (SICT) instrument consisting of 28 items, three pertaining to adherence. Simple and multivariate regression analyses assessed the relationship between satisfaction with different aspects of ICT and adherence. First assessments of the SICT instrument indicate its validity and reliability. Recommended thresholds for internal consistency, convergent validity, discriminant validity, and floor and ceiling effects were met. A number of variables were identified in the simple linear regression analyses as significant predictors of "never thinking about stopping ICT," a proxy for adherence. These significant variables were entered into the multivariate model to assess the combined factor effects, explaining 42% of the total variance of "never thinking about stopping ICT." A significant and positive relationship was demonstrated between "never thinking about stopping ICT" and age (P = 0.04), Perceived Effectiveness of ICT (P = 0.003), low Burden of ICT (P = 0.002), and low Side Effects of ICT (P = 0.01). The SICT is a reliable and valid instrument which will be useful in ICT clinical trials. Furthermore, the administration of ICT by slow subcutaneous infusion negatively impacts on satisfaction with ICT which was shown to be a determinant of adherence. This points to the need for new more convenient and less burdensome oral iron chelators to increase adherence, and ultimately to improve patient outcomes.

  14. SPRT Calibration Uncertainties and Internal Quality Control at a Commercial SPRT Calibration Facility

    Science.gov (United States)

    Wiandt, T. J.

    2008-06-01

    The Hart Scientific Division of the Fluke Corporation operates two accredited standard platinum resistance thermometer (SPRT) calibration facilities, one at the Hart Scientific factory in Utah, USA, and the other at a service facility in Norwich, UK. The US facility is accredited through National Voluntary Laboratory Accreditation Program (NVLAP), and the UK facility is accredited through UKAS. Both provide SPRT calibrations using similar equipment and procedures, and at similar levels of uncertainty. These uncertainties are among the lowest available commercially. To achieve and maintain low uncertainties, it is required that the calibration procedures be thorough and optimized. However, to minimize customer downtime, it is also important that the instruments be calibrated in a timely manner and returned to the customer. Consequently, subjecting the instrument to repeated calibrations or extensive repeated measurements is not a viable approach. Additionally, these laboratories provide SPRT calibration services involving a wide variety of SPRT designs. These designs behave differently, yet predictably, when subjected to calibration measurements. To this end, an evaluation strategy involving both statistical process control and internal consistency measures is utilized to provide confidence in both the instrument calibration and the calibration process. This article describes the calibration facilities, procedure, uncertainty analysis, and internal quality assurance measures employed in the calibration of SPRTs. Data will be reviewed and generalities will be presented. Finally, challenges and considerations for future improvements will be discussed.

  15. International Criminalization of International Terrorizm

    Directory of Open Access Journals (Sweden)

    Alexander Grigoryevich Volevodz

    2014-01-01

    Full Text Available Analysis and studying of the terrorism in all its facets is a complex entangled problem with less clear legal regulation that it might seem at first glance, especially after its transformation from local phenomenon into a world threat. Hitherto terrorism and actions connected to it have been criminalized by the majority of states. There are in modern criminal law whole systems of rules on criminal liability for terrorism which differs considerably from country to country. Terrorism has been criminalized in numerous international regional and universal antiterrorist legal instruments. The author notes that differences in definitions that are enshrined in them hinders international cooperation in criminal matters with respect to terrorist cases. Difficulties reside in the necessity to meet the dual criminality requirement and in the political offense exception. These difficulties can only be overcome through elaboration of a universally recognized definition of the notion of international terrorism and making it legally binding via its inclusion into a universal convention. The issue of definition of international terrorism is an important part of an efficient mutual assistance among states in fight against this crime. In this article the author accounts of actual ways of tackling by the international community of the issue of criminalization of international terrorism and of factors influencing them.

  16. Validation of an instrument to assess evidence-based practice knowledge, attitudes, access, and confidence in the dental environment.

    Science.gov (United States)

    Hendricson, William D; Rugh, John D; Hatch, John P; Stark, Debra L; Deahl, Thomas; Wallmann, Elizabeth R

    2011-02-01

    This article reports the validation of an assessment instrument designed to measure the outcomes of training in evidence-based practice (EBP) in the context of dentistry. Four EBP dimensions are measured by this instrument: 1) understanding of EBP concepts, 2) attitudes about EBP, 3) evidence-accessing methods, and 4) confidence in critical appraisal. The instrument-the Knowledge, Attitudes, Access, and Confidence Evaluation (KACE)-has four scales, with a total of thirty-five items: EBP knowledge (ten items), EBP attitudes (ten), accessing evidence (nine), and confidence (six). Four elements of validity were assessed: consistency of items within the KACE scales (extent to which items within a scale measure the same dimension), discrimination (capacity to detect differences between individuals with different training or experience), responsiveness (capacity to detect the effects of education on trainees), and test-retest reliability. Internal consistency of scales was assessed by analyzing responses of second-year dental students, dental residents, and dental faculty members using Cronbach coefficient alpha, a statistical measure of reliability. Discriminative validity was assessed by comparing KACE scores for the three groups. Responsiveness was assessed by comparing pre- and post-training responses for dental students and residents. To measure test-retest reliability, the full KACE was completed twice by a class of freshman dental students seventeen days apart, and the knowledge scale was completed twice by sixteen faculty members fourteen days apart. Item-to-scale consistency ranged from 0.21 to 0.78 for knowledge, 0.57 to 0.83 for attitude, 0.70 to 0.84 for accessing evidence, and 0.87 to 0.94 for confidence. For discrimination, ANOVA and post hoc testing by the Tukey-Kramer method revealed significant score differences among students, residents, and faculty members consistent with education and experience levels. For responsiveness to training, dental students

  17. New generation in process-control colorimetric instrumentation

    Science.gov (United States)

    Ladson, Jack A.

    1992-08-01

    Colorimetric performance parameters (repeatability and reproducibility) of a new spectrophotometer/colorimeter manufactured by BYK-Gardner, Inc. are reported. The color- viewTM spectrophotometer (CVS) uses forty-five degree illumination and zero degree viewing geometry relative to the plane of the test specimen. The CVS is designed for the measurement of diffuse reflectance factor. It is designed to conform to national and international recommendations for Spectrophotometry and Colorimetry. Colorimetric performance was evaluated by measuring colored tiles manufactured by the British Ceramic Research Association (BCRA). Instrument repeatability was recorded after an hour, eight hours, and thirty days. Routine performance of the CVS shows that color difference repeatability over short and medium time periods is within 0.15 CIELAB color difference unit. The long term repeatability is within 0.4 unit. Reproducibility was evaluated by making color measurements on BCRA tiles with 54 instruments. Measurements made on CVS instruments indicate that its reproducibility is better than the reproducibility of product standards. Reproducibility is well within the requirement for industrial applications. Actually, the repeatability and reproducibility is comparable to that of reference instruments in national standardizing laboratories.

  18. Systematizing the Instruments of Trade Wars and of Concealed Protectionism

    Directory of Open Access Journals (Sweden)

    Serpukhov Maksym Yu.

    2017-11-01

    Full Text Available The article is concerned with the problems of trade wars and hidden protectionism in the process of implementing international trade. The main purpose of the research is systematization of trade barriers and instruments used in the trade wars between countries. The basic instruments of trade wars have been analyzed, a list of the key instruments used in the trade wars between countries has been defined, and also the possible influence of these instruments has been described. The statistical analysis has resulted in identifying the main trade barriers and the most popular sectors of the economy in which protectionism instruments are applied. The authors have also defined the main interventions applied by different world countries in relation to Ukrainian products and groups of Ukrainian goods to which the most restrictions by the world countries are applied. The conclusions on counteraction and adaptation to the most popular instruments of protectionism in the process of activation of the export activity of country have been generalized.

  19. Development and Validation of an Instrument for Measuring Attitudes and Beliefs about Complementary and Alternative Medicine (CAM Use among Cancer Patients

    Directory of Open Access Journals (Sweden)

    Jun J. Mao

    2012-01-01

    Full Text Available Despite cancer patients' extensive use of complementary and alternative medicine (CAM, validated instruments to measure attitudes, and beliefs predictive of CAM use are lacking. We aimed at developing and validating an instrument, attitudes and beliefs about CAM (ABCAM. The 15-item instrument was developed using the theory of planned behavior (TPB as a framework. The literature review, qualitative interviews, expert content review, and cognitive interviews were used to develop the instrument, which was then administered to 317 outpatient oncology patients. The ABCAM was best represented as a 3-factor structure: expected benefits, perceived barriers, and subjective norms related to CAM use by cancer patients. These domains had Eigenvalues of 4.79, 2.37, and 1.43, and together explained over 57.2% of the variance. The 4-item expected benefits, 7-item perceived barriers, and 4-item subjective norms domain scores, each had an acceptable internal consistency (Cronbach's alpha of 0.91, 0.76, and 0.75, respectively. As expected, CAM users had higher expected benefits, lower perceived barriers, and more positive subjective norms (all <0.001 than those who did not use CAM. Our study provides the initial evidence that the ABCAM instrument produced reliable and valid scores that measured attitudes and beliefs related to CAM use among cancer patients.

  20. Measuring participation according to the International Classification of Functioning to

    NARCIS (Netherlands)

    Perenboom, R.J.M.; Chorus, A.M.J.

    2003-01-01

    Purpose of this study was to report which existing survey instruments assess participation according to the International Classification of Functioning. Disability and Health (ICF). A literature search for relevant survey instruments was conducted. Subsequently, survey instruments were evaluated of