WorldWideScience

Sample records for instrument iii testing

  1. The bone diagnostic instrument III: Testing mouse femora

    Science.gov (United States)

    Randall, Connor; Mathews, Phillip; Yurtsev, Eugene; Sahar, Nadder; Kohn, David; Hansma, Paul

    2009-06-01

    Here we describe modifications that allow the bone diagnostic instrument (BDI) [P. Hansma et al., Rev. Sci. Instrum. 79, 064303 (2008); Rev. Sci. Instrum. 77, 075105 (2006)], developed to test human bone, to test the femora of mice. These modifications include reducing the effective weight of the instrument on the bone, designing and fabricating new probe assemblies to minimize damage to the small bone, developing new testing protocols that involve smaller testing forces, and fabricating a jig for securing the smaller bones for testing. With these modifications, the BDI was used to test the hypothesis that short-term running has greater benefit on the mechanical properties of the femur for young growing mice compared to older, skeletally mature mice. We measured elastic modulus, hardness, and indentation distance increase (IDI), which had previously been shown to be the best discriminators in model systems known to exhibit differences in mechanical properties at the whole bone level. In the young exercised murine femora, the IDI was significantly lower than in young control femora. Since IDI has a relation to postyield properties, these results suggest that exercise during bone development increases post yield mechanical competence. We were also able to measure effects of aging on bone properties with the BDI. There was a significant increase in the IDI, and a significant decrease in the elastic modulus and hardness between the young and old groups. Thus, with the modifications described here, the BDI can take measurements on mouse bones and obtain statistically significant results.

  2. Football helmet drop tests on different fields using an instrumented Hybrid III head.

    Science.gov (United States)

    Viano, David C; Withnall, Chris; Wonnacott, Michael

    2012-01-01

    An instrumented Hybrid III head was placed in a Schutt ION 4D football helmet and dropped on different turfs to study field types and temperature on head responses. The head was dropped 0.91 and 1.83 m giving impacts of 4.2 and 6.0 m/s on nine different football fields (natural, Astroplay, Fieldturf, or Gameday turfs) at turf temperatures of -2.7 to 23.9 °C. Six repeat tests were conducted for each surface at 0.3 m (1') intervals. The Hybrid III was instrumented with triaxial accelerometers to determine head responses for the different playing surfaces. For the 0.91-m drops, peak head acceleration varied from 63.3 to 117.1 g and HIC(15) from 195 to 478 with the different playing surfaces. The lowest response was with Astroplay, followed by the engineered natural turf. Gameday and Fieldturf involved higher responses. The differences between surfaces decreased in the 1.83 m tests. The cold weather testing involved higher accelerations, HIC(15) and delta V for each surface. The helmet drop test used in this study provides a simple and convenient means of evaluating the compliance and energy absorption of football playing surfaces. The type and temperature of the playing surface influence head responses.

  3. Antithrombin III blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003661.htm Antithrombin III blood test To use the sharing features on this page, ... a protein that helps control blood clotting. A blood test can determine the amount of AT III present ...

  4. Bicep2. III. INSTRUMENTAL SYSTEMATICS

    International Nuclear Information System (INIS)

    Ade, P. A. R.; Aikin, R. W.; Bock, J. J.; Brevik, J. A.; Filippini, J. P.; Golwala, S. R.; Hildebrandt, S. R.; Barkats, D.; Benton, S. J.; Bischoff, C. A.; Buder, I.; Karkare, K. S.; Bullock, E.; Dowell, C. D.; Duband, L.; Fliescher, S.; Halpern, M.; Hasselfield, M.; Hilton, G. C.; Irwin, K. D.

    2015-01-01

    In a companion paper, we have reported a >5σ detection of degree scale B-mode polarization at 150 GHz by the Bicep2 experiment. Here we provide a detailed study of potential instrumental systematic contamination to that measurement. We focus extensively on spurious polarization that can potentially arise from beam imperfections. We present a heuristic classification of beam imperfections according to their symmetries and uniformities, and discuss how resulting contamination adds or cancels in maps that combine observations made at multiple orientations of the telescope about its boresight axis. We introduce a technique, which we call “deprojection,” for filtering the leading order beam-induced contamination from time-ordered data, and show that it reduces power in Bicep2's actual and null-test BB spectra consistent with predictions using high signal-to-noise beam shape measurements. We detail the simulation pipeline that we use to directly simulate instrumental systematics and the calibration data used as input to that pipeline. Finally, we present the constraints on BB contamination from individual sources of potential systematics. We find that systematics contribute BB power that is a factor of ∼10× below Bicep2's three-year statistical uncertainty, and negligible compared to the observed BB signal. The contribution to the best-fit tensor/scalar ratio is at a level equivalent to r = (3–6) × 10 −3

  5. Bicep2. III. INSTRUMENTAL SYSTEMATICS

    Energy Technology Data Exchange (ETDEWEB)

    Ade, P. A. R. [School of Physics and Astronomy, Cardiff University, Cardiff, CF24 3AA (United Kingdom); Aikin, R. W.; Bock, J. J.; Brevik, J. A.; Filippini, J. P.; Golwala, S. R.; Hildebrandt, S. R. [Department of Physics, California Institute of Technology, Pasadena, CA 91125 (United States); Barkats, D. [Joint ALMA Observatory, ESO, Santiago (Chile); Benton, S. J. [Department of Physics, University of Toronto, Toronto, ON (Canada); Bischoff, C. A.; Buder, I.; Karkare, K. S. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street MS 42, Cambridge, MA 02138 (United States); Bullock, E. [Minnesota Institute for Astrophysics, University of Minnesota, Minneapolis, MN 55455 (United States); Dowell, C. D. [Jet Propulsion Laboratory, Pasadena, CA 91109 (United States); Duband, L. [SBT, Commissariat à l’Energie Atomique, Grenoble (France); Fliescher, S. [Department of Physics, University of Minnesota, Minneapolis, MN 55455 (United States); Halpern, M.; Hasselfield, M. [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC (Canada); Hilton, G. C.; Irwin, K. D., E-mail: csheehy@uchicago.edu [National Institute of Standards and Technology, Boulder, CO 80305 (United States); Collaboration: Bicep2 Collaboration; and others

    2015-12-01

    In a companion paper, we have reported a >5σ detection of degree scale B-mode polarization at 150 GHz by the Bicep2 experiment. Here we provide a detailed study of potential instrumental systematic contamination to that measurement. We focus extensively on spurious polarization that can potentially arise from beam imperfections. We present a heuristic classification of beam imperfections according to their symmetries and uniformities, and discuss how resulting contamination adds or cancels in maps that combine observations made at multiple orientations of the telescope about its boresight axis. We introduce a technique, which we call “deprojection,” for filtering the leading order beam-induced contamination from time-ordered data, and show that it reduces power in Bicep2's actual and null-test BB spectra consistent with predictions using high signal-to-noise beam shape measurements. We detail the simulation pipeline that we use to directly simulate instrumental systematics and the calibration data used as input to that pipeline. Finally, we present the constraints on BB contamination from individual sources of potential systematics. We find that systematics contribute BB power that is a factor of ∼10× below Bicep2's three-year statistical uncertainty, and negligible compared to the observed BB signal. The contribution to the best-fit tensor/scalar ratio is at a level equivalent to r = (3–6) × 10{sup −3}.

  6. Testing Aircraft Instruments.

    Science.gov (United States)

    1981-02-11

    1. Have test data been collected, recorded, and presented in accordance with this TOP? Yes No Comment : 2. Were the facilities, test equipment...instrumentation, and support accommodations adequate to accomplish the test objectives? Yes No Comment : 3. Have all data collected been reviewed for...correctness and completeness? Yes No Comment : 4. Were the test results compromised in any way due to insufficient test planning? Yes No Comment : 5. Were the

  7. Virtual Sensor Test Instrumentation

    Science.gov (United States)

    Wang, Roy

    2011-01-01

    Virtual Sensor Test Instrumentation is based on the concept of smart sensor technology for testing with intelligence needed to perform sell-diagnosis of health, and to participate in a hierarchy of health determination at sensor, process, and system levels. A virtual sensor test instrumentation consists of five elements: (1) a common sensor interface, (2) microprocessor, (3) wireless interface, (4) signal conditioning and ADC/DAC (analog-to-digital conversion/ digital-to-analog conversion), and (5) onboard EEPROM (electrically erasable programmable read-only memory) for metadata storage and executable software to create powerful, scalable, reconfigurable, and reliable embedded and distributed test instruments. In order to maximize the efficient data conversion through the smart sensor node, plug-and-play functionality is required to interface with traditional sensors to enhance their identity and capabilities for data processing and communications. Virtual sensor test instrumentation can be accessible wirelessly via a Network Capable Application Processor (NCAP) or a Smart Transducer Interlace Module (STIM) that may be managed under real-time rule engines for mission-critical applications. The transducer senses the physical quantity being measured and converts it into an electrical signal. The signal is fed to an A/D converter, and is ready for use by the processor to execute functional transformation based on the sensor characteristics stored in a Transducer Electronic Data Sheet (TEDS). Virtual sensor test instrumentation is built upon an open-system architecture with standardized protocol modules/stacks to interface with industry standards and commonly used software. One major benefit for deploying the virtual sensor test instrumentation is the ability, through a plug-and-play common interface, to convert raw sensor data in either analog or digital form, to an IEEE 1451 standard-based smart sensor, which has instructions to program sensors for a wide variety of

  8. Instrumentation Cables Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Muna, Alice Baca [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); LaFleur, Chris Bensdotter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-10-01

    A fire at a nuclear power plant (NPP) has the potential to damage structures, systems, and components important to safety, if not promptly detected and suppressed. At Browns Ferry Nuclear Power Plant on March 22, 1975, a fire in the reactor building damaged electrical power and control systems. Damage to instrumentation cables impeded the function of both normal and standby reactor coolant systems, and degraded the operators’ plant monitoring capability. This event resulted in additional NRC involvement with utilities to ensure that NPPs are properly protected from fire as intended by the NRC principle design criteria (i.e., general design criteria 3, Fire Protection). Current guidance and methods for both deterministic and performance based approaches typically make conservative (bounding) assumptions regarding the fire-induced failure modes of instrumentation cables and those failure modes effects on component and system response. Numerous fire testing programs have been conducted in the past to evaluate the failure modes and effects of electrical cables exposed to severe thermal conditions. However, that testing has primarily focused on control circuits with only a limited number of tests performed on instrumentation circuits. In 2001, the Nuclear Energy Institute (NEI) and the Electric Power Research Institute (EPRI) conducted a series of cable fire tests designed to address specific aspects of the cable failure and circuit fault issues of concern1. The NRC was invited to observe and participate in that program. The NRC sponsored Sandia National Laboratories to support this participation, whom among other things, added a 4-20 mA instrumentation circuit and instrumentation cabling to six of the tests. Although limited, one insight drawn from those instrumentation circuits tests was that the failure characteristics appeared to depend on the cable insulation material. The results showed that for thermoset insulated cables, the instrument reading tended to drift

  9. Operational Test Instrumentation Guide.

    Science.gov (United States)

    1981-11-01

    System. A topographic, transit-level measuring system, instrumented with altimeter, clinometers, compasses , and an alidade, plane table, and stadia rod...dual hangar 250 x 135 feet with two door openings, 80 feet each. There is no compass swing base, no electronic landing aids, ro aircraft wash or...month) of SDG &E) Haybarn Canyon 15,000 6,183,870 Lan Pulgas 1,500 433,890 Las Pulgas Well #41621 100 4,258 Las Pulgas Well #41611 150 7,548 Las Flores

  10. Automated testing of health physics instruments

    International Nuclear Information System (INIS)

    Swinth, K.L.; Endres, A.W.; Hadley, R.T.; Kenoyer, J.L.

    1983-12-01

    A microcomputer controlled CAMAC system has been adapted for automated testing of health physics survey instruments. Once the survey instrument is positioned, the system automatically performs tests for angular dependence or battery lifetime. Rotation of the instrument is performed by a computer controlled stepping motor while readout is performed by an auto ranging digital volt meter and data stored on computer disks

  11. Millimeter-wave Instrumentation Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Millimeter-wave Instrumentation Test Facility conducts basic research in propagation phenomena, remote sensing, and target signatures. The facility has a breadth...

  12. Virtual Sensor Test Instrumentation, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Mobitrum has started the development of virtual sensor test instrumentation in Phase I for characterization and measurement of ground testing of propulsion systems....

  13. Doublet III construction and engineering test

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Progress during FY-78 on the construction and operation of the Doublet III is reported. Detailed discussions about the installation and testing of various components and subsystems, including the B-coil, E-coil, F-coils and support structure, vacuum vessel, vacuum pumping system, limiter, thermal insulation blanket, control system, B-coil power system, E-coil power system, F-coil power system, and motor-generator, are presented. A brief review of the engineering test operation is given

  14. Environmental Testing for Precision Parts and Instruments

    International Nuclear Information System (INIS)

    Choi, Man Yong; Park, Jeong Hak; Yun, Kyu Tek

    2001-01-01

    Precision parts and instruments are tested to evaluate performance in development-process and product-step to prement a potential defect due to a failure design. In this paper, Environmental test technology, which is the basis of reliability analysis, is introduced with examples of test criterion, test method for products, encoder and traffic signal controller, and measuring instruments. Recently, as the importance of the environmental test technology is recognised. It is proposed that training of test technician and technology of jig design and failure analysis are very essential

  15. Development of Multichannel Eddy Current Testing Instrument

    International Nuclear Information System (INIS)

    Lee, Hee Jong; Cho, Chan Hee; Nam, Min Woo; Yoon, Byung Sik; Yoo, Hyun Joo

    2010-01-01

    Four main techniques of electromagnetic testing are used for commercial applications: eddy current testing, alternating current field testing, magnetic flux leakage testing and remote field testing. Eddy current testing is a nondestructive evaluation method, which makes eddy current flow on a specimen by applying driving pulse to eddy current probe coil, by using eddy current testing device, and makes the change of eddy current which is dependently caused by flaws, material characteristics, testing condition, receiving through eddy current, and analyzes material properties, flaws, status on the specimen. Application of EC instrumentation varies widely in industry from the identification of metal heat treatment to the inspection of steam generator tubing in nuclear power plants. In this study, we have designed multichannel EC instrument which can be applicable to the NDE of the tube in heat exchanger for electric power facility, chemistry, and military industry, and finally confirmed the proper function of EC instrumentation

  16. Instrumentation and test gear circuits manual

    CERN Document Server

    Marston, R M

    2013-01-01

    Instrumentation and Test Gear Circuits Manual provides diagrams, graphs, tables, and discussions of several types of practical circuits. The practical circuits covered in this book include attenuators, bridges, scope trace doublers, timebases, and digital frequency meters. Chapter 1 discusses the basic instrumentation and test gear principles. Chapter 2 deals with the design of passive attenuators, and Chapter 3 with passive and active filter circuits. The subsequent chapters tackle 'bridge' circuits, analogue and digital metering techniques and circuitry, signal and waveform generation, and p

  17. Strategy for the development of EU Test Blanket Systems instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Calderoni, P., E-mail: Pattrick.Calderoni@f4e.europa.eu; Ricapito, I.; Poitevin, Y.

    2013-10-15

    Highlights: • We developed a strategy for the development of instrumentation for EU ITER TBSs. • TBSs instrumentation functions: safety, operation and scientific mission. • Described activities are in support of ITER design review process. -- Abstract: The instrumentation of the HCLL and HCPB Test Blanket System is fundamental in ensuring that ITER safety and operational requirements are satisfied as well as in enabling the scientific mission of the TBM program. It carries out three essential functions: (i) safety, intended as compliance with ITER requirements toward public and workers protection; (ii) system control, intended as compliance with ITER operational requirements and investment protection; and (iii) scientific mission, intended as validating technology and predictive tools for blanket concepts relevant to fusion energy systems. This paper describes the strategy for instrumentation development by providing details of the following five steps to be implemented in procured activities in the short to mid-term (3–4 years): (i) provide mapping of sensors requirements based on critical review of preliminary design data; (ii) develop functional specifications for TBS sensors based on the analysis of operative conditions in the various ITER buildings in which they are located; (iii) assess availability of commercial sensors against developed specifications; (iv) develop prototypes when no available solution is identified; and (v) perform single effect tests for the most critical solicitations and post-test examination of commercial products and prototypes. Examples of technology assessment in two technical areas are included to reinforce and complement the strategy description.

  18. FMIT test-end instrumentation conceptual design

    International Nuclear Information System (INIS)

    Fuller, J.L.

    1984-08-01

    FMIT test-end measurement techniques and instrumentation concepts for deuteron beam control, test-end device protection, test cell radiation field characterization, lithium jet performance monitoring, and in-situ off-line target testing and examination are described. The test-end refers to the beam line-target-test assembly interface area inside the test cell, but TEI includes measurements inside and outside the cell. The measurement requirements are briefly reviewed and referenced. The sometimes severe environmental limitations are discussed. Where feasible, multifunctional systems have been configured. Special facility features have been minimized

  19. Proceedings: Instrumentation and control test reduction workshop

    International Nuclear Information System (INIS)

    1991-09-01

    Instrumentation and control (I ampersand C) surveillance and testing is a significant contributor to operations and management costs. Several techniques to eliminate or reduce manual testing requirements could reduce costs while improving plant safety and performance. I ampersand C test reduction was the subject of this 1991 workshop. The workshop covered test elimination, test reduction, test automation, and relevant standards and benefits. The conclusions of the workshop were the following: More utility information sharing is important. There is a significant amount of information available throughout the industry, but it is not available in a concise, useable form. An I ampersand C utility users group is needed to address items such as instrument calibration reduction, set-point methodologies, and other current I ampersand C issues. The workshop was well received. The timing is right to initiate actions to reduce testing

  20. Standard practice for instrumented indentation testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice defines the basic steps of Instrumented Indentation Testing (IIT) and establishes the requirements, accuracies, and capabilities needed by an instrument to successfully perform the test and produce the data that can be used for the determination of indentation hardness and other material characteristics. IIT is a mechanical test that measures the response of a material to the imposed stress and strain of a shaped indenter by forcing the indenter into a material and monitoring the force on, and displacement of, the indenter as a function of time during the full loading-unloading test cycle. 1.2 The operational features of an IIT instrument, as well as requirements for Instrument Verification Annex A1), Standardized Reference Blocks (Annex A2) and Indenter Requirements (Annex A3) are defined. This practice is not intended to be a complete purchase specification for an IIT instrument. 1.3 With the exception of the non-mandatory Appendix X4, this practice does not define the analysis necessary...

  1. Simple Instrumental and Visual Tests for Nonlaboratory Environmental Control

    Directory of Open Access Journals (Sweden)

    L. P. Eksperiandova

    2016-01-01

    Full Text Available Proposed are simple and available techniques that can be used for rapid and reliable environmental control specifically of natural water by means of instrumental and visual tests in outdoor conditions. Developed are the chemical colorimetric modes for fast detection of socially dangerous trace impurities in water such as Co(II, Pd(II, and Rh(III as well as NO2--ions and Fe(III serving as model impurities. Application of portable digital devices and scanner allows estimating the color coordinates and increasing the accuracy and sensitivity of the tests. The combination of complex formation with preconcentration of colored complexes replaces the sensitive but time-consuming and capricious kinetic method that is usually used for this purpose at the more convenient and reliable colorimetric method. As the test tools, the following ones are worked out: polyurethane foam tablets with sorbed colored complexes, the two-layer paper sandwich packaged in slide adapter and saturated by reagents, and polyethylene terephthalate blister with dried reagents. Fast analysis of polyurethane foam tablets is realized using a pocket digital RGB-colorimeter or portable photometer. Express analysis of two-layer paper sandwich or polyethylene terephthalate blister is realized by visual and instrumental tests. The metrological characteristics of the developed visual and instrumental express analysis techniques are estimated.

  2. Instrumentation to Enhance Advanced Test Reactor Irradiations

    Energy Technology Data Exchange (ETDEWEB)

    J. L. Rempe; D. L. Knudson; K. G. Condie; J. E. Daw; S. C. Taylor

    2009-09-01

    The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support U.S. leadership in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR will support basic and applied nuclear research and development, further advancing the nation's energy security needs. A key component of the ATR NSUF effort is to prove new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. To address this need, an assessment of instrumentation available and under-development at other test reactors has been completed. Based on this review, recommendations are made with respect to what instrumentation is needed at the ATR and a strategy has been developed for obtaining these sensors. Progress toward implementing this strategy is reported in this document. It is anticipated that this report will be updated on an annual basis.

  3. Instrumentation to Enhance Advanced Test Reactor Irradiations

    International Nuclear Information System (INIS)

    Rempe, J.L.; Knudson, D.L.; Condie, K.G.; Daw, J.E.; Taylor, S.C.

    2009-01-01

    The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support U.S. leadership in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR will support basic and applied nuclear research and development, further advancing the nation's energy security needs. A key component of the ATR NSUF effort is to prove new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. To address this need, an assessment of instrumentation available and under-development at other test reactors has been completed. Based on this review, recommendations are made with respect to what instrumentation is needed at the ATR and a strategy has been developed for obtaining these sensors. Progress toward implementing this strategy is reported in this document. It is anticipated that this report will be updated on an annual basis.

  4. Laboratory test for ice adhesion strength using commercial instrumentation.

    Science.gov (United States)

    Wang, Chenyu; Zhang, Wei; Siva, Adarsh; Tiea, Daniel; Wynne, Kenneth J

    2014-01-21

    A laboratory test method for evaluating ice adhesion has been developed employing a commercially available instrument normally used for dynamic mechanical analysis (TA RSA-III). This is the first laboratory ice adhesion test that does not require a custom-built apparatus. The upper grip range of ∼10 mm is an enabling feature that is essential for the test. The method involves removal of an ice cylinder from a polymer coating with a probe and the determination of peak removal force (Ps). To validate the test method, the strength of ice adhesion was determined for a prototypical glassy polymer, poly(methyl methacrylate). The distance of the probe from the PMMA surface has been identified as a critical variable for Ps. The new test provides a readily available platform for investigating fundamental surface characteristics affecting ice adhesion. In addition to the ice release test, PMMA coatings were characterized using DSC, DCA, and TM-AFM.

  5. Technical testing of portable isotope identification instruments

    International Nuclear Information System (INIS)

    Smith, D.E.

    2001-01-01

    . First generation portable isotope identifiers were identified and evaluated by U.S. Customs. Instruments from five vendors were put through a battery of tests according to delineated test procedures. The tests fell into five categories: Basic operation verification; Medical isotope identification; Individual isotope identification; Isotope pair identification; Dose rate calculation. The tests can be summarized as an initial verification of correct instrument operation (including whatever calibration procedure was specified by the vendor), followed by three different isotope identification tests designed to verify the instrument's ability to correctly identify 19 isotopes specified by U.S. Customs. The final test determined each instrument's ability to correctly display the dose rate from a wide energy range of gamma emitters. The individual isotope identification test and the isotope pair identification test were performed with three types of intervening shielding. The first of these three types used the minimum packaging needed for safe source handling and was, in general, thin plastic. This type of shielding is virtually identical to a bare radiation source. The second type of shielding used 2.7 mm of steel to simulate the wall of a typical transportainer (or sea-tainer). The third type of shielding used 6.94 mm of lead to simulate typical industrial packaging or, perhaps, an attempt by the shipper to conceal the source without unduly increasing the weight of the shipment. The isotopes tested were broadly categorized as: Special nuclear material (SNM), Medical, and Industrial. These included 17 gamma emitters, 1 beta emitter, and 1 neutron emitter. Each instrument was subjected to the following testing regimen: First, each instrument was calibrated according to vendor's procedures. Instrument size and weight were recorded. Next, the instrument's response to medical isotopes in their usual shipping containers was measured. This represents the most commonly occurring

  6. Experience with the instrumentation tests in large sodium test facilities

    International Nuclear Information System (INIS)

    Lauhoff, Th.; Ruppert, E.; Stehle, H.; Vinzens, K.

    1976-01-01

    A facility is described for fast breeder core components (AKB) to test specially instrumented fuel dummies and blanket elements, and also absorber elements under simulated normal and extreme reactor conditions. In addition to endurance testing of a special sodium and high temperature sub-assembly, instrumentation is provided to investigate thermohydraulic and vibrational behaviour of core elements. During tests of > 3000 h at temperatures above 820 K the main sub-assembly characteristics, e.g. pressure drop, leakage flow, vibration and noise spectra can be reproduced. The use of eddy current flow meters, strain gauges, magnetostrictive noise sensors, pressure transducers, thermocouples, and acoustic surveillance devices, are described. (U.K.)

  7. Void fraction instrument acceptance test procedure

    International Nuclear Information System (INIS)

    Stokes, T.I.; Pearce, K.L.

    1994-01-01

    This document presents the results of the acceptance test for the mechanical and electrical features (not specifically addressed by the software ATP) of the void fraction instrument (VFI). Acceptance testing of the VFI, control console, and decontamination spray assembly was conducted in the 306E building high bay and area adjacent to the facility. The VFI was tested in the horizontal position supported in multiple locations on rolling tables. The control console was located next to the VFI pneumatic control assembly. The VFI system was operated exactly as is expected in the tank farm, with the following exceptions: power was provided from a building outlet and the VFI was horizontal. The testing described in this document verifies that the mechanical and electrical features are operating as designed and that the unit is ready for field service

  8. Advanced Instrumentation for Transient Reactor Testing

    Energy Technology Data Exchange (ETDEWEB)

    Corradini, Michael L.; Anderson, Mark; Imel, George; Blue, Tom; Roberts, Jeremy; Davis, Kurt

    2018-01-31

    Transient testing involves placing fuel or material into the core of specialized materials test reactors that are capable of simulating a range of design basis accidents, including reactivity insertion accidents, that require the reactor produce short bursts of intense highpower neutron flux and gamma radiation. Testing fuel behavior in a prototypic neutron environment under high-power, accident-simulation conditions is a key step in licensing nuclear fuels for use in existing and future nuclear power plants. Transient testing of nuclear fuels is needed to develop and prove the safety basis for advanced reactors and fuels. In addition, modern fuel development and design increasingly relies on modeling and simulation efforts that must be informed and validated using specially designed material performance separate effects studies. These studies will require experimental facilities that are able to support variable scale, highly instrumented tests providing data that have appropriate spatial and temporal resolution. Finally, there are efforts now underway to develop advanced light water reactor (LWR) fuels with enhanced performance and accident tolerance. These advanced reactor designs will also require new fuel types. These new fuels need to be tested in a controlled environment in order to learn how they respond to accident conditions. For these applications, transient reactor testing is needed to help design fuels with improved performance. In order to maximize the value of transient testing, there is a need for in-situ transient realtime imaging technology (e.g., the neutron detection and imaging system like the hodoscope) to see fuel motion during rapid transient excursions with a higher degree of spatial and temporal resolution and accuracy. There also exists a need for new small, compact local sensors and instrumentation that are capable of collecting data during transients (e.g., local displacements, temperatures, thermal conductivity, neutron flux, etc.).

  9. Acoustic emission measurement during instrumented impact tests

    International Nuclear Information System (INIS)

    Crostack, H.A.; Engelhardt, A.H.

    1983-01-01

    Results of instrumented impact tests are discussed. On the one hand the development of the loading process at the hammer tup was recorded by means of a piezoelectric transducer. This instrumentation supplied a better representation of the load versus time than the conventional strain gauges. On the other hand the different types of acoustic emission occurring during a test could be separated. The acoustic emission released at the impact of the hammer onto the specimen is of lower frequency and its spectrum is strongly decreasing with increasing frequency. Plastic deformation also emits signals of lower frequency that are of quasi-continuous character. Both signal types can be discriminated by filtering. As a consequence typical burst signal were received afterwards that can be correlated with crack propagation. Their spectra exhibit considerable portions up to about 1.9 MHz. The development in time of the burst signals points to the kind of crack propagation resp. its sequence of appearance. However, definitive comparison between load and acoustic emission should become possible, only when the disadvantages of the common load measurement can be reduced, e.g. by determining the load directly at the specimen instead of the hammer tup

  10. Water NSTF Design, Instrumentation, and Test Planning

    Energy Technology Data Exchange (ETDEWEB)

    Lisowski, Darius D.; Gerardi, Craig D.; Hu, Rui; Kilsdonk, Dennis J.; Bremer, Nathan C.; Lomperski, Stephen W.; Kraus, Adam R.; Bucknor, Matthew D.; Lv, Qiuping; Farmer, Mitchell T.

    2017-08-01

    variations and off-normal configurations. The facility design follows, including as-built dimensions and specifications of the various mechanical and liquid systems, design choices for the test section, water storage tank, and network piping. Specifications of the instrumentation suite are then presented, along with specific information on performance windows, measurement uncertainties, and installation locations. Finally, descriptions of the control systems and heat removal networks are provided, which have been engineered to support precise quantification of energy balances and facilitate well-controlled test operations.

  11. Irradiation test of FPGA for BES III

    International Nuclear Information System (INIS)

    Chen Yixin; Liang Hao; Xue Jundong; Liu Baoying; Liu Qiang; Yu Xiaoqi; Zhou Yongzhao; Hou Long

    2005-01-01

    The irradiation effect of FPGA, applied in Front-end Electronics for experiments of High-Energy Physics, is a serious problem. The performance of FPGA, used in the front-end card of Muon Counters of BES III project, needs to be evaluated under irradiation. SEUs on Altera ACEX 1K FPGA, observed in the experiment under the irradiation of γ ray, 14 and 2.5 MeV neutrons, was investigated. The authors calculated involved cross-section and provided reasonable analysis and evaluation for the result of the experiment. The conclusion about feasibility of applying ACEX 1K FPGA in the front-end card of the readout system of Muon Counters for BES III was given. (authors)

  12. TREFF: Reflectometer and instrument component test beamline at MLZ

    Directory of Open Access Journals (Sweden)

    Peter Link

    2017-11-01

    Full Text Available TREFF is a high resolution polarized neutron reflectometer and instrument component test beamline resulting in a highly modular instrument providing a flexible beam line for various applications.

  13. [The development of an oral biomechanical testing instrument].

    Science.gov (United States)

    Zhang, X H; Sun, X D; Lin, Z

    2000-03-01

    An oral biomechanical testing instrument, which is portable, powered with batteries and controlled by single chip microcomputer, was described. The instrument was characterized by its multichannel, high accuracy, low power dissipation, wide rage of force measurement and stable performance. It can be used for acquisiting, displaying and storing data. And it may be expected to be an ideal instrument for oral biomechanical measurements.

  14. SMORN-III benchmark test on reactor noise analysis methods

    International Nuclear Information System (INIS)

    Shinohara, Yoshikuni; Hirota, Jitsuya

    1984-02-01

    A computational benchmark test was performed in conjunction with the Third Specialists Meeting on Reactor Noise (SMORN-III) which was held in Tokyo, Japan in October 1981. This report summarizes the results of the test as well as the works made for preparation of the test. (author)

  15. Designing stability tests of nuclear instrumentation

    International Nuclear Information System (INIS)

    Viererbl, L.; Novakova, O.

    1981-01-01

    The stability tests used are described including the test of the peak maximum position differential measurement, the test of the pulse rate measurement using integral evaluation, the quality test, the chi 2 test, the 3σ test. The test of measuring pulse rate by integral evaluation was found to be the most accurate. Its modifications and generalization gave the proposed stability tests, viz., the A test and the B test. Examples are described of stability tests for a spectrometric system, the NRG 302 dose rate converter, a proportional counter. (H.S.)

  16. W-026, health physics instrumentation operational test report

    International Nuclear Information System (INIS)

    Hackworth, M.F.

    1998-01-01

    This report documents the testing of the Health Physics Instrumentation associated with phase 2 and 3 start-up of Project W-026, WRAP. The Health Physics Instrumentation includes: Alpha and Beta Continuous Air Monitors (CAMS), Personnel Contamination Monitors (PCMs), Gamma Area Radiation Monitors (ARMs), Criticality Monitors, Alpha and Beta Smear Sample Counters, Portable Friskers, and Operator Breathing Zone Air Samplers. This OTR will cover only the Health Physics Instrumentation that was tested under the Operational test Plan for Health Physics Instrumentation (Phase 2 and 3). That instrumentation included: Alpha CAMS, Beta CAMs and ARMs located in rooms 107 and 113 of 2336-W. The remaining Health Physics Instrumentation that will be used for phase 2 and 3 start-up is tested during calibrations. These calibrations are outside the scope of the Operational Test Plan

  17. Non-process instrumentation surveillance and test reduction

    International Nuclear Information System (INIS)

    Ferrell, R.; LeDonne, V.; Donat, T.; Thomson, I.; Sarlitto, M.

    1993-12-01

    Analysis of operating experience, instrument failure modes, and degraded instrument performance has led to a reduction in Technical Specification surveillance and test requirements for nuclear power plant process instrumentation. These changes have resulted in lower plant operations and maintenance (O ampersand M) labor costs. This report explores the possibility of realizing similar savings by reducing requirements for non-process instrumentation. The project team reviewed generic Technical Specifications for the four major US nuclear steam supply system (NSSS) vendors (Westinghouse, General Electric, Combustion Engineering, and Babcock ampersand Wilcox) to identify nonprocess instrumentation for which surveillance/test requirements could be reduced. The team surveyed 10 utilities to identify specific non-process instrumentation at their plants for which requirements could be reduced. The team evaluated utility analytic approaches used to justify changes in surveillance/test requirements for process equipment to determine their applicability to non-process instrumentation. The report presents a prioritized list of non-process instrumentation systems suitable for surveillance/test requirements reduction. The top three systems in the list are vibration monitors, leak detection monitors, and chemistry monitors. In general, most non-process instrumentation governed by Technical Specification requirements are candidates for requirements reduction. If statistical requirements are somewhat relaxed, the analytic approaches previously used to reduce requirements for process instrumentation can be applied to non-process instrumentation. The report identifies as viable the technical approaches developed and successfully used by Southern California Edison, Arizona Public Service, and Boston Edison

  18. Technological considerations in emergency instrumentation preparedness. Phase II-D. Evaluation testing and calibration methodology for emergency radiological instrumentation

    International Nuclear Information System (INIS)

    Bramson, P.E.; Andersen, B.V.; Fleming, D.M.; Kathren, R.L.; Mulhern, O.R.; Newton, C.E.; Oscarson, E.E.; Selby, J.M.

    1976-09-01

    In response to recommendations from the Advisory Committee on Reactor Safeguards, the Division of Operational Safety, U.S. ERDA has contracted with Battelle, Pacific Northwest Laboratories to survey the adequacy of existing instrumentation at nuclear fuel cycle facilities to meet emergency requirements and to develop technical criteria for instrumentation systems to be used in assessment of environmental conditions following plant emergencies. This report, the fifth in a series, provides: (1) calibration methods to assure the quality of radiological measurements and (2) testing procedures for determining whether an emergency radiological instrument meets the performance specifications. Three previous reports in this series identified the emergency instrumentation needs for power reactors, mixed oxide fuel plants, and fuel reprocessing facilities. Each of these three reports contains a Section VI, which sets forth applicable radiological instrument performance criteria and calibration requirements. Testing and calibration procedures in this report have been formatted in two parts: IV and V, each divided into three subsections: (1) Power Reactors, (2) Mixed Oxide Fuel Plants, and (3) Fuel Reprocessing Facilities. The three performance criteria subsections directly coincide with the performance criteria sections of the previous reports. These performance criteria sections have been reproduced in this report as Part III with references of ''required action'' added

  19. Flight Test Guide (Part 61 Revised): Instrument Pilot: Helicopter.

    Science.gov (United States)

    Federal Aviation Administration (DOT), Washington, DC. Flight Standards Service.

    The guide provides an outline of the skills required to pass the flight test for an Instrument Pilot Helicopter Rating under Part 61 (revised) of Federal Aviation Regulations. General procedures for flight tests are described and the following pilot operations outlined: maneuvering by reference to instruments, IFR navigation, instrument…

  20. FMIT test-end instrumentation development bases

    International Nuclear Information System (INIS)

    Fuller, J.L.

    1982-06-01

    FMIT test-end measurements proposed for deuteron beam control, target diagnostics, and irradiation sample dosimetry are listed. The test-end refers to the area inside the test cell, but includes measurements inside and outside the cell. Justification, categorization, and limits qualification are presented for each measurement. Methods are purposefully de-emphasized in order to clarify the measurement needs, not techniques. Some discussion of techniques currently under investigation is given in the last section of the report

  1. Beam instrumentation for an ISOL test stand

    International Nuclear Information System (INIS)

    Mackenzie, G.H.; Dombsky, M.; Rawnsley, W.; Stanford, G.; Yin, Y.; Novikov, A.

    1995-09-01

    TRIUMF is constructing a test bed for the first stages of the proposed TISAC accelerated radioactive beam facility. The authors will present the requirements for the diagnostic system for this test stand and describe the design and development work underway. Scintillators, beamstops and a Faraday Cup have been tested using stable, mass analyzed, 12 keV beams of ions from mass 14 to 132. The design of a linear drive, with 10 microm resolution, for scanning wires and slits has begun

  2. Beam instrumentation for an ISOL test stand

    International Nuclear Information System (INIS)

    Mackenzie, G.H.; Dombsky, M.; Rawnsley, W.; Stanford, G.; Yin, Y.; Novikov, A.

    1995-09-01

    TRIUMF is constructing a test bed for the first stages of the proposed TISAC accelerated radioactive beam facility. We will present the requirements for the diagnostic system for this test stand and describe the design and development work underway. Scintillators, beamstops and Faraday Cup have been tested using stable, mass analyzed, 12 keV beams of ions from mass 14 to 132. The design of a linear drive, with 10 μm resolution, for scanning wires and slits has begun. (author)

  3. Falsification Testing of Instrumental Variables Methods for Comparative Effectiveness Research.

    Science.gov (United States)

    Pizer, Steven D

    2016-04-01

    To demonstrate how falsification tests can be used to evaluate instrumental variables methods applicable to a wide variety of comparative effectiveness research questions. Brief conceptual review of instrumental variables and falsification testing principles and techniques accompanied by an empirical application. Sample STATA code related to the empirical application is provided in the Appendix. Comparative long-term risks of sulfonylureas and thiazolidinediones for management of type 2 diabetes. Outcomes include mortality and hospitalization for an ambulatory care-sensitive condition. Prescribing pattern variations are used as instrumental variables. Falsification testing is an easily computed and powerful way to evaluate the validity of the key assumption underlying instrumental variables analysis. If falsification tests are used, instrumental variables techniques can help answer a multitude of important clinical questions. © Health Research and Educational Trust.

  4. International standardization of instruments for neutron irradiation tests

    International Nuclear Information System (INIS)

    Tanimoto, Masataka; Shibata, Akira; Nakamura, Jinichi; Tsuchiya, Kunihiko; Cho, M.; Lee, C.; Park, S.; Choo, K.

    2012-01-01

    The JMTR in JAEA and HANARO in KAERI are the foremost testing/research reactors in the world and these are expected to contribute to many nuclear fields. As a part of instrument development in irradiation field, information exchange of instruments started from 2010 under the cooperation agreements between KAERI and JAEA. The instruments developed in JMTR and HANARO are introduced and cooperation experiments as future plan are discussed for international standardization. (author)

  5. The Mark III vertex chamber and prototype test results

    International Nuclear Information System (INIS)

    Grab, C.

    1987-07-01

    A vertex chamber has been constructed for use in the Mark III experiment. The chamber is positioned inside the current main drift chamber and will be used to trigger data collection, to aid in vertex reconstruction, and to improve the momentum resolution. This paper discusses the chamber's construction and performance and tests of the prototype

  6. Performance tests for instruments measuring radon activity concentration

    International Nuclear Information System (INIS)

    Beck, T.R.; Buchroeder, H.; Schmidt, V.

    2009-01-01

    Performance tests of electronic instruments measuring the activity concentration of 222 Rn have been carried out with respect to the standard IEC 61577-2. In total, 9 types of instrument operating with ionization chambers or electrostatic collection have been tested for the influence of different climatic and radiological factors on the measurement characteristics. It is concluded that all types of instrument, which are commercially available, are suitable for indoor radon measurements. Because of the dependence on climatic conditions, the outdoor use is partly limited.

  7. Phase III Simplified Integrated Test (SIT) results - Space Station ECLSS testing

    Science.gov (United States)

    Roberts, Barry C.; Carrasquillo, Robyn L.; Dubiel, Melissa Y.; Ogle, Kathryn Y.; Perry, Jay L.; Whitley, Ken M.

    1990-01-01

    During 1989, phase III testing of Space Station Freedom Environmental Control and Life Support Systems (ECLSS) began at Marshall Space Flight Center (MSFC) with the Simplified Integrated Test. This test, conducted at the MSFC Core Module Integration Facility (CMIF), was the first time the four baseline air revitalization subsystems were integrated together. This paper details the results and lessons learned from the phase III SIT. Future plans for testing at the MSFC CMIF are also discussed.

  8. 49 CFR 572.200 - Instrumentation and test conditions.

    Science.gov (United States)

    2010-10-01

    ... TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES IIsD... Test, unless noted otherwise. (g) All instrumented response signal measurements shall be treated to the... conform to the Sign Convention For Vehicle Crash Testing, Surface Vehicle Information Report, SAE J1733...

  9. Testing as an inevitable instrument in today's language learning ...

    African Journals Online (AJOL)

    In the foregoing analysis, we have unequivocably declared that testing or assessment is an inevitable instrument in present day's language learning environment and that testing is the other side of teaching itself. In teaching any aspect of language, learner must be tested to determine the progress made so far as well as ...

  10. 49 CFR 572.21 - Test conditions and instrumentation.

    Science.gov (United States)

    2010-10-01

    ...-Year-Old Child § 572.21 Test conditions and instrumentation. (a)(1) The test probe used for head and... surface of the lumbar spine, and 0.3 inches dorsal to the accelerometer mounting plate surface. (1) The.... For thorax and lumbar spine tests, the seating surface is without the back support as shown in Figures...

  11. 49 CFR 572.127 - Test conditions and instrumentation.

    Science.gov (United States)

    2010-10-01

    ...-year-old Child Test Dummy, Beta Version § 572.127 Test conditions and instrumentation. (a) The test... ends of ribs #1 and #6 and at the spine box at the levels of #1 and #6 ribs as shown in 127-0000 sheet...) The optional lumbar spine force-moment transducer shall have the dimensions, response characteristics...

  12. Powertrain instrumentation and test systems development, hybridization, electrification

    CERN Document Server

    Paulweber, Michael

    2016-01-01

    The book deals with the increasingly complex test systems for powertrain components and systems giving an overview of the diverse types of test beds for all components of an advanced powertrain focusing on specific topics such as instrumentation, control, simulation, hardware-in-the-loop, automation or test facility management. This book is intended for powertrain (component) development engineers, test bed planners, test bed operators and beginners.

  13. Instrumentation and control of the Doublet III Neutral Beam Injector System

    Energy Technology Data Exchange (ETDEWEB)

    Kohli, J.C.; Moore, C.D.; Drobnis, D.D.; Elischer, V.P.; Kilgore, R.; Uber, D.

    1980-03-01

    The hardware and software required for the operation of the Doublet III Neutral Beam Injector System (NBIS) are described. Development and implementation of this Instrumentation and Control System was divided between the major participants - General Atomic Company and Lawrence Berkeley Laboratory. The subdivision of responsibilities and the coordination of the participants' activities are described with reference to hardware and software requirements in support of the entire system. Included are a description of the operators' consoles, the interlock system and the CAMAC system. One feature of the control software is source modeling. This feature includes feedback on a shot to shot basis and adaptive control. Adaptive control permits the computer system to automatically adjust parameters after a shot, and to control the system to automatically compensate for time varying NBIS components. The Neutral Beam Power Supply features power supply modeling, fiber optic transmission of analog signals and digital control of power supply power-up/interlocks.

  14. Instrumentation and control of the Doublet III Neutral Beam Injector System

    International Nuclear Information System (INIS)

    Kohli, J.C.; Moore, C.D.; Drobnis, D.D.; Elischer, V.P.; Kilgore, R.; Uber, D.

    1980-03-01

    The hardware and software required for the operation of the Doublet III Neutral Beam Injector System (NBIS) are described. Development and implementation of this Instrumentation and Control System was divided between the major participants - General Atomic Company and Lawrence Berkeley Laboratory. The subdivision of responsibilities and the coordination of the participants' activities are described with reference to hardware and software requirements in support of the entire system. Included are a description of the operators' consoles, the interlock system and the CAMAC system. One feature of the control software is source modeling. This feature includes feedback on a shot to shot basis and adaptive control. Adaptive control permits the computer system to automatically adjust parameters after a shot, and to control the system to automatically compensate for time varying NBIS components. The Neutral Beam Power Supply features power supply modeling, fiber optic transmission of analog signals and digital control of power supply power-up/interlocks

  15. Experiment data of ROSA-III integral test Run 7341

    International Nuclear Information System (INIS)

    Anoda, Yoshinari; Soda, Kunihisa; Tasaka, Kanji

    1983-02-01

    This report presents the test data of Run 7341 in the single failure test series of the ROSA-III program to conduct the system effect test concerning the response of a BWR during a LOCA with the ECC injection. The ROSA-III test facility is a volumetrically scaled (1/424) system of the BWR/6 with an electrically heated core and the scaled ECCS. Run 7341 is a double-ended break test at the recirculation pump inlet with the assumption that all ECCS function as designed. The test is initiated with the steam dome pressure of 7.28 MPa, the lower plenum subcooling of 11.0 K, the core inlet flow rate of 15.3 kg/s, and the core heat generation rate of 3.55 MW and proceeded as planned. The whole core is quenched after the ECCS actuation and the maximum fuel cladding temperature is 810 K. The effectiveness of ECC injection has been clarified from the comparison of the test results with those of the other test in the series without ECCS. (author)

  16. Instrumentation and measurement method for the ATLAS test facility

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Byong Jo; Chu, In Chul; Eu, Dong Jin; Kang, Kyong Ho; Kim, Yeon Sik; Song, Chul Hwa; Baek, Won Pil

    2007-03-15

    An integral effect test loop for pressurized water reactors (PWRs), the ATLAS is constructed by thermal-hydraulic safety research division in KAERI. The ATLAS facility has been designed to have the length scale of 1/2 and area scale of 1/144 compared with the reference plant, APR1400 which is a Korean evolution type nuclear reactors. A total 1300 instrumentations is equipped in the ATLAS test facility. In this report, the instrumentation of ATLAS test facility and related measurement methods were introduced.

  17. Nuclear instrumentation system operating experience and nuclear instrument testing in the EBR-II

    International Nuclear Information System (INIS)

    Yingling, G.E.; Curran, R.N.

    1980-01-01

    In March of 1972 three wide range nuclear channels were purchased from Gulf Atomics Corporation and installed in EBR-II as a test. The three channels were operated as a test until April 1975 when they became a permanent part of the reactor shutdown system. Also described are the activities involved in evaluating and qualifying neutron detectors for LMFBR applications. Included are descriptions of the ANL Components Technology Division Test Program and the EBR-II Nuclear Instrument Test Facilities (NITF) used for the in-reactor testing and a summary of program test results from EBR-II

  18. Acceptance test procedure, 241-SY-101 Flexible Receiver System, Phase III testing

    International Nuclear Information System (INIS)

    Ritter, G.A.

    1994-01-01

    This Acceptance Test Procedure is for the 241-SY-101 Flexible Receiver System, Phase III Testing. This procedure will test the sealing integrity of the Flexible Receiver System to ensure that release of waste and aerosols will be minimized during the removal of the test mixer pump from tank SY-101

  19. Design type testing for digital instrumentation and control systems

    International Nuclear Information System (INIS)

    Bastl, W.; Mohns, G.

    1997-01-01

    The design type qualification of digital safety instrumentation and control is outlined. Experience shows that the concepts discussed, derived from codes, guidelines and standards, achieve useful results. It has likewise become clear that the systematics of design type qualification of the hardware components is also applicable to the software components. Design type qualification of the software, a premiere, could be performed unexpectedly smoothly. The hardware design type qualification proved that the hardware as a substrate of functionality and reliability is an issue that demands full attention, as compared to conventional systems. Another insight is that design qualification of digital instrumentation and control systems must include plant-independent systems tests. Digital instrumentation and control systems simply work very differently from conventional control systems, so that this testing modality is inevitable. (Orig./CB) [de

  20. Doublet III neutral beam injector test tank cryopanel design

    International Nuclear Information System (INIS)

    Doll, D.W.; Kamperschroer, J.H.; Arend, P.V.

    1980-03-01

    A simple condensing cryopanel has been designed for the Doublet III neutral beam test tank with a 320,000 liters per second pumping capacity for hydrogen. This maintains a vacuum in the test tank which simulates the Doublet III vessel, 1.3 x 10 -3 Pa (approx.10 -5 torr). The hydrogen gas load comes from the beam striking the test tank calorimeter and amounts to about 7.2 torr liters per second. The cryopanel is cylindrical shaped with a liquid helium (LHe) surface that pumps through liquid nitrogen (LN) cooled aluminum chevrons located in squirrel-cage fashion around the inside surface of the cylinder. The LHe cooled surface is a smooth cylinder 2.09m in diameter by .69m long with LHe flowing in a approx. 1mm annular space between concentric cylinders. The chevrons which are not blackened are cooled from each end with LN flowing in ring manifolds that serve as the primary cryopanel structure. The LHe is force fed at 55.2 kPa remaining in the liquid phase through the panel. External heat exchanger capability permits use of helium at 3.8 to 4.2 0 K. Normal operating flow rate is 1.4 g/sec for a heat load expected to be 12.2 W total

  1. Experimental studies and tests on An(III)/Ln(III) separation using the TODGA extractant

    Energy Technology Data Exchange (ETDEWEB)

    Heres, Xavier; Sorel, Christian; Miguirditchian, Manuel; Cames, Beatrice; Hill, Clement; Bisel, Isabelle; Espinoux, Denis; Viallesoubranne, Carole; Baron, Pascal; Lorrain, Brigitte [CEA/DEN/MAR/DRCP, Marcoule, BP17171, 30207 Bagnols/Ceze (France)

    2009-06-15

    Minor actinide recycling by separation and transmutation is worldwide considered as one of the most promising strategies to reduce the inventory of radioactive waste, thus contributing to make nuclear energy more sustainable. One of the different options investigated at the CEA Marcoule and within the ACSEPT project (a European collaborative project partly funded by the 7. EURATOM Framework Program) to separate trivalent minor actinide (Am(III)-Cf(III)) from the fission and activation products contained in PUREX raffinates is the TODGA process, which consists in: 1. Co-extracting trivalent 4f and 5f elements from highly acidic PUREX raffinates by a mixture of TODGA (tetraoctyl-diglycolamide) and TBP (tributyl-phosphate), dissolved in HTP (hydrogenated tetra-propene). 2. Selectively stripping the trivalent minor actinides by a hydrophilic poly-aminocarboxylic acid used as a complexing agent in a buffered aqueous solution, while the trivalent lanthanides are kept in the organic solvent thanks to a sodium nitrate salting-out effect. 3. Stripping the lanthanides in a diluted nitric acid solution. The major difficulty of this TODGA separation process is to tune the pH in a very narrow range of operating conditions in the second step, because of the high sensitivity of the performances of the flow-sheet vs pH. This difficulty was however overcome. This paper describes the development of the TODGA process from experimental studies to hot test implementation in shielded cells of the ATALANTE facility, including (i) the optimization of the extraction system (both the formulation of the organic solvent and those of the aqueous scrubbing and stripping solutions), (ii) the implementation of a cold test in small scale mixer-settlers in the G1 facility (MARCEL loop), using a surrogate feed composed of major fission products, (iii) the validation of some steps of the process, using a surrogate feed, spiked with Am-241 and Eu-152, and similar laboratory contactors (medium activity

  2. Characterization of the Goubau line for testing beam diagnostic instruments

    Science.gov (United States)

    Kim, S. Y.; Stulle, F.; Sung, C. K.; Yoo, K. H.; Seok, J.; Moon, K. J.; Choi, C. U.; Chung, Y.; Kim, G.; Woo, H. J.; Kwon, J.; Lee, I. G.; Choi, E. M.; Chung, M.

    2017-12-01

    One of the main characteristics of the Goubau line is that it supports a low-loss, non-radiated surface wave guided by a dielectric-coated metal wire. The dominant mode of the surface wave along the Goubau line is a TM01 mode, which resembles the pattern of the electromagnetic fields induced in the metallic beam pipe when the charged particle beam passes through it. Therefore, the Goubau line can be used for the preliminary bench test and performance optimization of the beam diagnostic instruments without requiring charged particle beams from the accelerators. In this paper, we discuss the basic properties of the Goubau line for testing beam diagnostic instruments and present the initial test results for button-type beam position monitors (BPMs). The experimental results are consistent with the theoretical estimations, which indicates that Goubau line allows effective testing of beam diagnostic equipment.

  3. Disturbance induced by surface preparation on instrumented indentation test

    International Nuclear Information System (INIS)

    Li, Yugang; Kanouté, Pascale; François, Manuel

    2015-01-01

    Surface preparation, which may induce considerable sample disturbance, plays an important role in instrumented indentation test (IIT). In this study, the sample disturbance (mainly divided into residual stresses and plastic strain) induced by the surface preparation process of instrumented indentation test specimens were investigated with both experimental tests and numerical simulations. Grazing incidence X-ray diffractions (GIXRD) and uniaxial tensile tests were conducted for characterizing the residual stresses and high plastic strain in the top surface layers of a carefully mechanically polished indentation sample, which, in the present work, is made of commercially pure titanium. Instrumented indentation tests and the corresponding finite element simulations were performed as well. For comparison, a reference sample (carefully mechanically polished & electrolytically polished) which represents the raw material was prepared and tested. Results showed that a careful mechanical polishing procedure can effectively reduce the level of residual stresses induced by this process. However, the high plastic strain in the surface region imposed by the polishing process is significant. The induced plastic strain can affect a depth up to 5 µm, which is deeper than the maximum penetration depth h max (3 µm) used for the instrumented indentation tests. In the near surface layer (in the range of depth about 350 nm), the plastic strain levels are fairly high. In the very top layer, the plastic strain was even estimated to reach more than 60%. The simultaneous use of indentation tests and numerical simulations showed that the existence of high plastic strain in the surface region will make the load vs depth (P–h) curve shift upwards, the contact hardness (H) increase and the contact stiffness (S) decrease

  4. Disturbance induced by surface preparation on instrumented indentation test

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yugang, E-mail: yugang.li@utt.fr [Université de Technologie de Troyes (UTT), ICD-LASMIS, UMR CNRS 6281, 12, rue Marie Curie-CS 42060, 10010 Troyes Cedex (France); Kanouté, Pascale, E-mail: pascale.kanoute@onera.fr [Université de Technologie de Troyes (UTT), ICD-LASMIS, UMR CNRS 6281, 12, rue Marie Curie-CS 42060, 10010 Troyes Cedex (France); The French Aerospace Lab (ONERA), DMSM/MCE, 29 avenue de la Division Leclerc-BP 72, F-92322 Chatillon Cedex (France); François, Manuel, E-mail: manuel.francois@utt.fr [Université de Technologie de Troyes (UTT), ICD-LASMIS, UMR CNRS 6281, 12, rue Marie Curie-CS 42060, 10010 Troyes Cedex (France)

    2015-08-26

    Surface preparation, which may induce considerable sample disturbance, plays an important role in instrumented indentation test (IIT). In this study, the sample disturbance (mainly divided into residual stresses and plastic strain) induced by the surface preparation process of instrumented indentation test specimens were investigated with both experimental tests and numerical simulations. Grazing incidence X-ray diffractions (GIXRD) and uniaxial tensile tests were conducted for characterizing the residual stresses and high plastic strain in the top surface layers of a carefully mechanically polished indentation sample, which, in the present work, is made of commercially pure titanium. Instrumented indentation tests and the corresponding finite element simulations were performed as well. For comparison, a reference sample (carefully mechanically polished & electrolytically polished) which represents the raw material was prepared and tested. Results showed that a careful mechanical polishing procedure can effectively reduce the level of residual stresses induced by this process. However, the high plastic strain in the surface region imposed by the polishing process is significant. The induced plastic strain can affect a depth up to 5 µm, which is deeper than the maximum penetration depth h{sub max} (3 µm) used for the instrumented indentation tests. In the near surface layer (in the range of depth about 350 nm), the plastic strain levels are fairly high. In the very top layer, the plastic strain was even estimated to reach more than 60%. The simultaneous use of indentation tests and numerical simulations showed that the existence of high plastic strain in the surface region will make the load vs depth (P–h) curve shift upwards, the contact hardness (H) increase and the contact stiffness (S) decrease.

  5. Instrumentation and testing of a prestressed concrete containment vessel model

    International Nuclear Information System (INIS)

    Hessheimer, M.F.; Pace, D.W.; Klamerus, E.W.

    1997-01-01

    Static overpressurization tests of two scale models of nuclear containment structures - a steel containment vessel (SCV) representative of an improved, boiling water reactor (BWR) Mark II design and a prestressed concrete containment vessel (PCCV) for pressurized water reactors (PWR) - are being conducted by Sandia National Laboratories for the Nuclear Power Engineering Corporation of Japan and the U.S. Nuclear Regulatory Commission. This paper discusses plans for instrumentation and testing of the PCCV model. 6 refs., 2 figs., 2 tabs

  6. Experimental fast reactor JOYO MK-III functional test. Primary auxiliary cooling system test

    International Nuclear Information System (INIS)

    Karube, Koji; Akagi, Shinji; Terano, Toshihiro; Onuki, Osamu; Ito, Hideaki; Aoki, Hiroshi; Odo, Toshihiro

    2004-03-01

    This paper describes the results of primary auxiliary cooling system, which were done as a part of JOYO MK-III function test. The aim of the tests was to confirm the operational performance of primary auxiliary EMP and the protection system including siphon breaker of primary auxiliary cooling system. The items of the tests were: (Test No.): (Test item). 1) SKS-117: EMP start up test. 2) SKS-118-1: EMP start up test when pony motor running. 3) SKS-121: Function test of siphon breaker. The results of the tests satisfied the required performance, and demonstrated successful operation of primary auxiliary cooling system. (author)

  7. 75 FR 76636 - Anthropomorphic Test Devices; Hybrid III 6-Year-Old Child Test Dummy, Hybrid III 6-Year-Old...

    Science.gov (United States)

    2010-12-09

    ... provision: ``When a motor vehicle safety standard is in effect under this chapter, a State or a political... [Docket No. NHTSA-2010-0147] RIN 2127-AK34 Anthropomorphic Test Devices; Hybrid III 6-Year-Old Child Test Dummy, Hybrid III 6-Year-Old Weighted Child Test Dummy AGENCY: National Highway Traffic Safety...

  8. The VUV instrument SPICE for Solar Orbiter: performance ground testing

    Science.gov (United States)

    Caldwell, Martin E.; Morris, Nigel; Griffin, Douglas K.; Eccleston, Paul; Anderson, Mark; Pastor Santos, Carmen; Bruzzi, Davide; Tustain, Samuel; Howe, Chris; Davenne, Jenny; Grundy, Timothy; Speight, Roisin; Sidher, Sunil D.; Giunta, Alessandra; Fludra, Andrzej; Philippon, Anne; Auchere, Frederic; Hassler, Don; Davila, Joseph M.; Thompson, William T.; Schuehle, Udo H.; Meining, Stefan; Walls, Buddy; Phelan, P.; Dunn, Greg; Klein, Roman M.; Reichel, Thomas; Gyo, Manfred; Munro, Grant J.; Holmes, William; Doyle, Peter

    2017-08-01

    SPICE is an imaging spectrometer operating at vacuum ultraviolet (VUV) wavelengths, 70.4 - 79.0 nm and 97.3 - 104.9 nm. It is a facility instrument on the Solar Orbiter mission, which carries 10 science instruments in all, to make observations of the Sun's atmosphere and heliosphere, at close proximity to the Sun, i.e to 0.28 A.U. at perihelion. SPICE's role is to make VUV measurements of plasma in the solar atmosphere. SPICE is designed to achieve spectral imaging at spectral resolution >1500, spatial resolution of several arcsec, and two-dimensional FOV of 11 x16arcmins. The many strong constraints on the instrument design imposed by the mission requirements prevent the imaging performance from exceeding those of previous instruments, but by being closer to the sun there is a gain in spatial resolution. The price which is paid is the harsher environment, particularly thermal. This leads to some novel features in the design, which needed to be proven by ground test programs. These include a dichroic solar-transmitting primary mirror to dump the solar heat, a high in-flight temperature (60deg.C) and gradients in the optics box, and a bespoke variable-line-spacing grating to minimise the number of reflective components used. The tests culminate in the systemlevel test of VUV imaging performance and pointing stability. We will describe how our dedicated facility with heritage from previous solar instruments, is used to make these tests, and show the results, firstly on the Engineering Model of the optics unit, and more recently on the Flight Model. For the keywords, select up to 8 key terms for a search on your manuscript's subject.

  9. Testing for the Best Instrument to Generate Sustainable Food Consumption

    Directory of Open Access Journals (Sweden)

    Luca Panzone

    2011-12-01

    Full Text Available  The increase in the level of greenhouse gas (GHG emissions in the atmosphere in the last centuries, and the subsequent increase in temperature, has been a widely studied area in the last few decades. Climate change has become a key item on the political agenda due to concerns regarding the sustainability of current human consumption for future generations. Consumption of food and agricultural goods constitutes an important part of household based GHG emissions, and the relatively low costs associated with environmental improvements make it an interesting area of study to understand behavioural changes. Despite general agreement on the need to curb the amount of GHG emissions worldwide, little evidence exists regarding the best instruments policymakers can employ to stimulate changes toward more sustainable consumption. The present work explores which instruments are most effective in fostering change to more environmentally friendly food consumption. The instruments tested are CO2 labelling, GHG abatement subsidy and product-specific bans. We used a simulated online shopping trip in supermarkets in the Greater London area in the United Kingdom, where respondents shopped in four product categories: cola, milk, meat (chicken and beef, and butter/margarine. Consumer preferences reveal that, in the presence of these instruments, quantity instruments performed better than price incentives and labelling.

  10. ROSA-III 50 % break integral test RUN 916

    International Nuclear Information System (INIS)

    Yonomoto, Taisuke; Tasaka, Kanji; Koizumi, Yasuo; Anoda, Yoshinari; Kumamaru, Hiroshige; Nakamura, Hideo; Suzuki, Mitsuhiro; Murata, Hideo

    1985-08-01

    This report presents the experimental data of RUN 916 conducted at the ROSA-III test facility. The facility is a volumetrically scaled (1/424) simulator for a BWR/6 with the electrically heated core, the break simulator and the scaled ECCS(emergency core cooling system). RUN 916 was a 50 % split break test at the recirculation pump suction line with an assumption of HPCS diegel generator failure and conducted as one of the break area parameter tests. A peak cladding temperature (PCT) of 917 K was reached at 190 s after the break during the reflooding phase. Whole core was completely quenched by ECCS, and the effectiveness of ECCS was confermed. The primary test results of RUN 916 are compared in this report with those of RUN 926, which was a 200 % double-ended break test. The initiation of core dryout in RUN 916 was later than that in RUN 926 because of the smaller discharge flow rate. Duration of core dryourt was, however, longer in RUN 916 because of later actuation of ECCSs. PCT in RUN 916 was 133 K higher than that in RUN 926. (author)

  11. ROSA-III 100 % break integral test Run 914

    International Nuclear Information System (INIS)

    Yonomoto, Taisuke; Tasaka, Kanji; Koizumi, Yasuo; Anoda, Yoshinari; Kumamaru, Hiroshige; Nakamura, Hideo; Suzuki, Mitsuhiro; Murata, Hideo

    1987-05-01

    This report presents the experimental data of RUN 914 conducted at the ROSA-III test facility. The facility is a volumetrically scaled (1/424) simulator for a BWR/6 with the electrically heated core, the break simulator and the scaled ECCS (emergency core cooling system). RUN 914 was a 100% split break test at the recirculation pump suction line with an assumption of HPCS diesel generator failure and conducted as one of the break area parameter tests. A peak cladding temperature (PCT) of 851 K was reached at 130 s after the break during the reflooding phase. Whole core was completely quenched by ECCS, and the effectiveness of ECCS was confirmed. The primary test results of RUN 914 are compared in this report with those of RUN 926, which was a 200 % double-ended break test. The initiation of core dryout in RUN 914 was almost the same as that in RUN 926. Duration of core dryourt was, however, longer in RUN 914 because of later actuation of ECCSs. PCT in RUN 914 was 67 K higher than that in RUN 926. (author)

  12. Dynamic instrumentation for the K-1600 seismic test facility recommissioning

    International Nuclear Information System (INIS)

    VanHoy, B.W.

    1991-01-01

    Martin Marietta Energy Systems, Inc. is the site contractor to the Department of Energy (DOE) for three Oak Ridge, Tennessee sites, the site in Portsmouth, Ohio, and the site in Paducah, Kentucky. To provide a focus for all natural phenomena engineering related problems, Martin Marietta Energy Systems, Inc. established the Center for Natural Phenomena Engineering under the technical direction of Dr. James E. Beavers. One of the Center's mandates is the determination of seismic properties of building structures containing sensitive processes. This has led to the recommissioning of the K-1600 Seismic Test Facility. The biaxial shake table in this facility was constructed during the eighties for seismic qualification of equipment of the Gas Centrifuge Enrichment Plant. After construction of the plant was terminated the Seismic Test Facility was placed in standby where it was left for six years. The facility's original instrumentation was evaluated versus the required instrumentation to augment its new expanded mission parameters. Instrumentation selection involving technology changes, age and attrition, and the new mission goals are discussed in this paper along with the rationale and budget that were involved with each decision. The testing potential of this facility along with the instrumentation upgrades necessary to accomplish these new tasks for the Center for Natural Phenomena Engineering are considered. New uses such as seismic qualification of equipment utilized in DOE's missions at various sites and waste treatment are proposed. This instrumentation selection is discussed in detail to show the rationale and proposed used of the facility as well as the capabilities of this DOE resource

  13. Vehicle for transporting instruments for testing against a wall

    International Nuclear Information System (INIS)

    Hyde, E.A.; Goldsmith, H.A.; Proudlove, M.J.

    1981-01-01

    This invention relates to a non-destructive testing apparatus and, in particular, to a vehicle that can be moved at will, for transporting instruments for testing against a surface remote from the operator. Under this invention a vehicle is intended, for instance, for testing the vessel of an installation containing a liquid metal cooled nuclear reactor of the pond type. Such an installation includes a nuclear reactor comprising an assembly containing a nuclear fuel immersed in a pond of liquid metal coolant, located in a vessel which is itself placed in a concrete containment vessel [fr

  14. Instrumentation and test of the Swiss LCT-coil

    International Nuclear Information System (INIS)

    Zichy, J.A.; Horvath, I.; Jakob, B.; Marinucci, C.; Vecsey, G.; Weymuth, P.; Zellweger, J.

    1985-01-01

    Just before Christmas 1983 the fabrication of the Swiss LCT-coil was finished. Tests at ambient temperature were performed on the factory site and after delivery in Oak Ridge. To avoid an undesirable delay of the rescheduled Partial-Array Test it was agreed to install the coil without its superconducting bus. In July 1984 the Swiss LCT-coil was successfully cooled down to LHe temperature together with the other two fully installed coils. Besides the cooling system, the instrumentation, measured parameters of the coil and some preliminary results obtained during the ongoing Partial-Array Test are presented

  15. Quality of prenatal care questionnaire: instrument development and testing

    Science.gov (United States)

    2014-01-01

    Background Utilization indices exist to measure quantity of prenatal care, but currently there is no published instrument to assess quality of prenatal care. The purpose of this study was to develop and test a new instrument, the Quality of Prenatal Care Questionnaire (QPCQ). Methods Data for this instrument development study were collected in five Canadian cities. Items for the QPCQ were generated through interviews with 40 pregnant women and 40 health care providers and a review of prenatal care guidelines, followed by assessment of content validity and rating of importance of items. The preliminary 100-item QPCQ was administered to 422 postpartum women to conduct item reduction using exploratory factor analysis. The final 46-item version of the QPCQ was then administered to another 422 postpartum women to establish its construct validity, and internal consistency and test-retest reliability. Results Exploratory factor analysis reduced the QPCQ to 46 items, factored into 6 subscales, which subsequently were validated by confirmatory factor analysis. Construct validity was also demonstrated using a hypothesis testing approach; there was a significant positive association between women’s ratings of the quality of prenatal care and their satisfaction with care (r = 0.81). Convergent validity was demonstrated by a significant positive correlation (r = 0.63) between the “Support and Respect” subscale of the QPCQ and the “Respectfulness/Emotional Support” subscale of the Prenatal Interpersonal Processes of Care instrument. The overall QPCQ had acceptable internal consistency reliability (Cronbach’s alpha = 0.96), as did each of the subscales. The test-retest reliability result (Intra-class correlation coefficient = 0.88) indicated stability of the instrument on repeat administration approximately one week later. Temporal stability testing confirmed that women’s ratings of their quality of prenatal care did not change as a result of giving

  16. Quality of prenatal care questionnaire: instrument development and testing.

    Science.gov (United States)

    Heaman, Maureen I; Sword, Wendy A; Akhtar-Danesh, Noori; Bradford, Amanda; Tough, Suzanne; Janssen, Patricia A; Young, David C; Kingston, Dawn A; Hutton, Eileen K; Helewa, Michael E

    2014-06-03

    Utilization indices exist to measure quantity of prenatal care, but currently there is no published instrument to assess quality of prenatal care. The purpose of this study was to develop and test a new instrument, the Quality of Prenatal Care Questionnaire (QPCQ). Data for this instrument development study were collected in five Canadian cities. Items for the QPCQ were generated through interviews with 40 pregnant women and 40 health care providers and a review of prenatal care guidelines, followed by assessment of content validity and rating of importance of items. The preliminary 100-item QPCQ was administered to 422 postpartum women to conduct item reduction using exploratory factor analysis. The final 46-item version of the QPCQ was then administered to another 422 postpartum women to establish its construct validity, and internal consistency and test-retest reliability. Exploratory factor analysis reduced the QPCQ to 46 items, factored into 6 subscales, which subsequently were validated by confirmatory factor analysis. Construct validity was also demonstrated using a hypothesis testing approach; there was a significant positive association between women's ratings of the quality of prenatal care and their satisfaction with care (r = 0.81). Convergent validity was demonstrated by a significant positive correlation (r = 0.63) between the "Support and Respect" subscale of the QPCQ and the "Respectfulness/Emotional Support" subscale of the Prenatal Interpersonal Processes of Care instrument. The overall QPCQ had acceptable internal consistency reliability (Cronbach's alpha = 0.96), as did each of the subscales. The test-retest reliability result (Intra-class correlation coefficient = 0.88) indicated stability of the instrument on repeat administration approximately one week later. Temporal stability testing confirmed that women's ratings of their quality of prenatal care did not change as a result of giving birth or between the early postpartum

  17. Pipe Overpack Container Fire Testing: Phase I II & III.

    Energy Technology Data Exchange (ETDEWEB)

    Figueroa, Victor G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ammerman, Douglas J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lopez, Carlos [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gill, Walter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2018-02-01

    The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire, resulting in one of the 7A drum overpacks generating sufficient internal pressure to pop off its lid and expose the top of the pipe container (PC) to the fire environment. The initial contents of the POCs were inert materials, which would not generate large internal pressure within the PC if heated. POCs are now being used to store combustible TRU waste at Department of Energy (DOE) sites. At the request of DOE’s Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), starting in 2015 SNL conducted a series of fire tests to examine whether PCs with combustibles would reach a temperature that would result in (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to over-pressurize and release its inner content. Tests conducted during 2015 and 2016 were done in three phases. The goal of the first phase was to see if the PC would reach high enough temperatures to decompose typical combustible materials inside the PC. The goal of the second test phase was to determine under what heating loads (i.e., incident heat fluxes) the 7A drum lid pops off from the POC drum. The goal of the third phase was to see if surrogate aerosol gets released from the PC when the drum lid is off. This report will describe the various tests conducted in phase I, II, and III, present preliminary results from these tests, and discuss implications for the POCs.

  18. Experiment data of ROSA-III integral test RUN 710

    International Nuclear Information System (INIS)

    Koizumi, Yasuo; Tasaka, Kanji; Adachi, Hiromichi; Anoda, Yoshinari; Soda, Kunihisa

    1981-01-01

    The report presents data of RUN 710 at ROSA-III test facility. RUN 710 simulates a 200% double-ended break at the inlest side of a recirculation pump of a BWR. All ECCS are activated and electric power to simulated fuel rods in one core channel among four is not supplied in RUN 710. The primary initial conditions are steam dome pressure 7.35 MPa, lower plenum subcooling 10.8 K, core inlet flow rate 31.3 kg/s and core heat generation 2.42 MW. Peak cladding temperature is 609 K at Position 3, 352.5 mm above the mid plane of the core. All heater rods are quenched after ECCS actuation and the effectiveness of ECCS is confirmed. (author)

  19. Mid Infrared Instrument cooler subsystem test facility overview

    Science.gov (United States)

    Moore, B.; Zan, J.; Hannah, B.; Chui, T.; Penanen, K.; Weilert, M.

    2017-12-01

    The Cryocooler for the Mid Infrared Instrument (MIRI) on the James Webb Space Telescope (JWST) provides cooling at 6.2K on the instrument interface. The cooler system design has been incrementally documented in previous publications [1][2][3][4][5]. It has components that traverse three primary thermal regions on JWST: Region 1, approximated by 40K; Region 2, approximated by 100K; and Region 3, which is at the allowable flight temperatures for the spacecraft bus. However, there are several sub-regions that exist in the transition between primary regions and at the heat reject interfaces of the Cooler Compressor Assembly (CCA) and Cooler Control Electronics Assembly (CCEA). The design and performance of the test facility to provide a flight representative thermal environment for acceptance testing and characterization of the complete MIRI cooler subsystem are presented.

  20. Eddy current testing system for bottom mounted instrumentation welds

    OpenAIRE

    Kobayashi Noriyasu; Ueno Souichi; Suganuma Naotaka; Oodake Tatsuya; Maehara Takeshi; Kasuya Takashi; Ichikawa Hiroya

    2015-01-01

    The capability of eddy current testing (ECT) for the bottom mounted instrumentation (BMI) weld area of reactor vessel in a pressurized water reactor was demonstrated by the developed ECT system and procedure. It is difficult to position and move the probe on the BMI weld area because the area has complexly curved surfaces. The space coordinates and the normal vectors at the scanning points were calculated as the scanning trajectory of probe based on the measured results of surface shape on th...

  1. Disassembly and removal of sodium instrumentation test loop

    International Nuclear Information System (INIS)

    Ishikawa, Okinobu; Onojima, Takamitu; Nagai, Keiichi

    2000-07-01

    In 1999, the Sodium Instrumentation Test Loop was disassembled and removed. This report describes the tasks and experiences obtained in removing sodium from a storage tank, disassembling, and cleansing components and related activities. Overall the disassembly, handling and cleansing tasks proceeded as planned and the activities were carried out efficiently and safely. Documentation of the process is meant to establish not only a procedure, but also a guideline for future similar tasks. (author)

  2. SuperAGILE onboard electronics and ground test instrumentation

    International Nuclear Information System (INIS)

    Pacciani, Luigi; Morelli, Ennio; Rubini, Alda; Mastropietro, Marcello; Porrovecchio, Geiland; Costa, Enrico; Del Monte, Ettore; Donnarumma, Immacolata; Evangelista, Yuri; Feroci, Marco; Lazzarotto, Francesco; Rapisarda, Massimo; Soffitta, Paolo

    2007-01-01

    In this paper we describe the electronics of the SuperAGILE X-ray imager on-board AGILE satellite and the instrumentation developed to test and improve the Front-End and digital electronics of the flight model of the imager. Although the working principle of the instrument is very well established, and the conceptual scheme simple, the budget and mechanical constraints of the AGILE small mission made necessary the introduction of new elements in SuperAGILE, regarding both the mechanics and the electronics. In fact the instrument is contained in a ∼44x44x16cm 3 volume, but the required performance is quite ambitious, leading us to equip a sensitive area of ∼1350cm 2 with 6144 Silicon μstrips detectors with a pitch of 121μm and a total length of ∼18.2cm. The result is a very light and power-cheap imager with a good sensitivity (∼15mCrab in 1 day in 15-45keV), high angular resolution (6arcmin) and gross spectral resolution. The test-equipment is versatile, and can be easily modified to test FEE based on self-triggered, data-driven and sparse-readout ASICs such as XA family chips

  3. Instrumented impact testing machine with reduced specimen oscillation effects

    International Nuclear Information System (INIS)

    Rintamaa, R.; Rahka, K.; Wallin, K.

    1984-07-01

    Owing to small and inexpensive specimens the Charpy impact test is widely used in quality control and alloy development. Limitations in power reactor survellance capsules it is also widely used for safety analysis purposes. Instrumenting the tup and computerizing data acquisition, makes dynamic fracture mechanics data measurement possible and convenient. However, the dynamic effects (inertia forces, specimen oscillations) in the impact test cause inaccuracies in the recorded load-time diagram and hence diminish the reliability of the calculated dynamic fracture mechanics parameters. To decrease inaccuracies a new pendulum type of instrumented impact test apparatus has been developed and constructed in the Metals Laboratory of the Technical Research Centre of Finland. This tester is based on a new principle involving inverted test geometry. The purpose of the geometry inversion is to reduce inertia load and specimen oscillation effects. Further, the new impact tester has some other novel features: e.g. the available initia impact energy is about double compared to the conventional standard (300 J) impact tester allowing the use of larger (10 x 20 x 110 mm) bend specimens than normal Charpy specimens. Also, the rotation asix in the three point bending is nearly stationary making COD-measurements possible. An experimental test series is described in which the inertia effects and specimen oscillations are compared in the conventional and new impact tester utilizing Charpy V-notch specimens. Comparison of the two test geometries is also made with the aid of an analytical model using finite element method (FEM) analysis. (author)

  4. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-09-15

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  5. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    International Nuclear Information System (INIS)

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-01-01

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  6. Testing of full size high current superconductors in SULTAN III

    Science.gov (United States)

    Blau, B.; Rohleder, I.; Vecsey, G.; Pasotti, G.; Ricci, M. V.; Sacchetti, N.; Bruzzone, P.; Katheder, H.; Mitchell, N.; Bessette, D.

    1994-07-01

    The high field test facility SULTAN III in operation at PSI/Switzerland tests full size industrial prototype superconductors for fusion applications such as ITER. The facility provides a background field of up to 11 T over a length of 58 cm. A 50 kA superconducting transformer works as a very low noise current source which allows a criterion of 0.1 mu V/cm to determine the superconducting to normal transition. Three 3.6 m long cable-in-conduit conductors based on both NbTi and Nb3Sn, developed by different manufacturers, suitable for the central solenoid and toroidal field coils of ITER, have been tested so far. This paper presents the results of extensive measurements of critical current and current sharing temperature of the Nb3Sn conductors in the 8 - 11 T range for temperatures between 4.5 K and 11 K. Voltage versus current curves have been analyzed with respect to the n value. The manufacturing of a high quality joint between two Nb3Sn conductors after heat treatment is reported, together with some measurements of the joint resistance.

  7. Testing of full size high current superconductors in SULTAN III

    International Nuclear Information System (INIS)

    Blau, B.; Rohleder, I.; Vecsey, G.

    1994-01-01

    The high field test facility SULTAN III in operation at PSI/Switzerland tests full size industrial prototype superconductors for fusion applications such as ITER. The facility provides a background field of up to 11 T over a length of 58 cm. A 50 kA superconducting transformer works as a very low noise current source which allows a criterion of 0.1 μV/cm to determine the superconducting to normal transition. Three 3.6 m long cable-in-conduit conductors based on both NbTi and Nb 3 Sn, developed by different manufacturers, suitable for the central solenoid and toroidal field coils of ITER, have been tested so far. This paper presents the results of extensive measurements of critical current and current sharing temperature of the Nb 3 Sn conductors in the 8--11 T range for temperatures between 4.5 K and 11 K Voltage versus current curves have been analyzed with respect to the n value. The manufacturing of a high quality joint between two Nb 3 Sn conductors after heat treatment is reported, together with some measurements of the joint resistance

  8. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid N

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This is a Test Report for Acceptance Test Procedure (ATP) RPP-5489. This test report provides the results of the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''N''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document

  9. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid M

    International Nuclear Information System (INIS)

    KOCH, M.R.

    1999-01-01

    This is a Test Report for Acceptance Test Procedure (ATP) RPP-5073. This test report provides the results of the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''M''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document

  10. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid L

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    1999-11-09

    This is a Test Report for Acceptance Test Procedure (ATP) RPP-5055. This test report provides the results of the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''L''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document.

  11. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid L

    International Nuclear Information System (INIS)

    KOCH, M.R.

    1999-01-01

    This is a Test Report for Acceptance Test Procedure (ATP) RPP-5055. This test report provides the results of the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''L''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document

  12. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid M

    Energy Technology Data Exchange (ETDEWEB)

    KOCH, M.R.

    1999-12-13

    This is a Test Report for Acceptance Test Procedure (ATP) RPP-5073. This test report provides the results of the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''M''. The ATP was successfully completed. A copy of the completed ATP is in the Appendix of this document.

  13. Comparison of cough reflex test against instrumental assessment of aspiration.

    Science.gov (United States)

    Miles, Anna; Moore, Sara; McFarlane, Mary; Lee, Fiona; Allen, Jacqueline; Huckabee, Maggie-Lee

    2013-06-13

    Silent aspiration is associated with pneumonia and mortality, and is poorly identified by traditional clinical swallowing evaluation (CSE). The aim of this study was to validate cough reflex testing (CRT) for identification of silent aspiration against aspiration confirmed by instrumental assessment. Cough reflex threshold testing was completed on all patients using inhaled, nebulised citric acid. Within an hour, 80 patients underwent videofluoroscopic study of swallowing (VFSS) and 101 patients underwent fibreoptic endoscopic evaluation of swallowing (FEES). All tests were recorded and analysed by two researchers blinded to the result of the alternate test. Significant associations between CRT result and cough response to aspiration on VFSS (X(2) (2)=11.046, p=.003) and FEES (X(2) (2)=34.079, pacid provide a better predictive measure of silent aspiration. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. The Hydraulic Test Procedure for Non-instrumented Irradiation Test Rig of Annular Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Lee, Kang Hee; Shin, Chang Hwan; Park, Chan Kook

    2008-08-15

    This report presents the procedure of pressure drop test, vibration test and endurance test for the non-instrumented rig using the irradiation test in HANARO of advanced PWR annular fuel which were designed and fabricated by KAERI. From the out-pile thermal hydraulic tests, confirm the flow rate at the 200 kPa pressure drop and measure the RMS displacement at this time. And the endurance test is confirmed the wear and the integrity of the non-instrumented rig at the 110% design flow rate. This out-pile test perform the Flow-Induced Vibration and Pressure Drop Experimental Tester(FIVPET) facility. The instruments in FIVPET facility was calibrated in KAERI and the pump and the thermocouple were certified by manufacturer.

  15. Advanced In-pile Instrumentation for Material and Test Reactors

    International Nuclear Information System (INIS)

    Rempe, J.L.; Knudson, D.L.; Daw, J.E.; Unruh, T.C.; Chase, B.M.; Davis, K.L.; Palmer, A.J.; Schley, R.S.

    2013-06-01

    The US Department of Energy sponsors the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) program to promote U.S. research in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR NSUF facilitates basic and applied nuclear research and development, advancing U.S. energy security needs. A key component of the ATR NSUF effort is to design, develop, and deploy new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. This paper describes the strategy developed by the Idaho National Laboratory (INL) for identifying instrumentation needed for ATR irradiation tests and the program initiated to obtain these sensors. New sensors developed from this effort are identified; and the progress of other development efforts is summarized. As reported in this paper, INL staff is currently involved in several tasks to deploy real-time length and flux detection sensors, and efforts have been initiated to develop a crack growth test rig. Tasks evaluating 'advanced' technologies, such as fiber-optics based length detection and ultrasonic thermometers are also underway. In addition, specialized sensors for real-time detection of temperature and thermal conductivity are not only being provided to NSUF reactors, but are also being provided to several international test reactors. (authors)

  16. Advanced In-Pile Instrumentation for Materials Testing Reactors

    Science.gov (United States)

    Rempe, J. L.; Knudson, D. L.; Daw, J. E.; Unruh, T. C.; Chase, B. M.; Davis, K. L.; Palmer, A. J.; Schley, R. S.

    2014-08-01

    The U.S. Department of Energy sponsors the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) program to promote U.S. research in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR NSUF facilitates basic and applied nuclear research and development, advancing U.S. energy security needs. A key component of the ATR NSUF effort is to design, develop, and deploy new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. This paper describes the strategy developed by the Idaho National Laboratory (INL) for identifying instrumentation needed for ATR irradiation tests and the program initiated to obtain these sensors. New sensors developed from this effort are identified, and the progress of other development efforts is summarized. As reported in this paper, INL researchers are currently involved in several tasks to deploy real-time length and flux detection sensors, and efforts have been initiated to develop a crack growth test rig. Tasks evaluating `advanced' technologies, such as fiber-optics based length detection and ultrasonic thermometers, are also underway. In addition, specialized sensors for real-time detection of temperature and thermal conductivity are not only being provided to NSUF reactors, but are also being provided to several international test reactors.

  17. Total dose tests for the PROMICS-3 instrument

    International Nuclear Information System (INIS)

    Verkasalo, R.

    1991-01-01

    The sensitivity of some analog and digital integrated circuits (IC's) to ionizing radiation was tested in order to evaluate their potential usefulness especially in the PROMICS-3 instrument. The PROMICS-3 is a plasma instrument to be flown on the Russian Interball satellites. The radiation tolerance requirement of the auroral Interball satellite is about 45 krad/year inside a shielding of 4 mm Aluminium. The IC's tested were: AD571 A/D- converter, ADDAC80 D/A-converter, LF442A and PM108A operational amplifiers, MPREF0l voltage reference, STC SPXO 6 MHZ oscillator,4N55 optocoupler, MC5lC98 and CY7C164 16k*4 static CMOS RAM. Co-60 was used as the irradiation source. The test methods and results are described in the paper. The RAM-circuits failed between 10 and 20 krad. D/A- and A/D-converters degraded only slightly after 100 krad, but one of the A/D-converters failed functionally at 190 krad. The LF442A began to degrade in the test connection at 100 krad, and PM108A at 30 krad. The output voltage of the voltage reference MPREF01 increased about 20 mV after 100 krad. No change was observed in the output frequency of the STC SPXD oscillator even after 300 krad. The current tansfer ratio of the 4N55 decreased continuously to about 75 % of the initial value after 100 krad

  18. Performance specifications for health physics instrumentation: portable instrumentation for use in normal work environments. Part 2. Test results

    International Nuclear Information System (INIS)

    Kenoyer, J.L.; Swinth, K.L.; Stoetzel, G.A.; Selby, J.M.

    1986-09-01

    The Pacific Northwest Laboratory evaluated a draft American National Standards Institute Standard N42.17 (ANSI N42.17) on performance specifications for health physics instrumentation through a project jointly funded by the US Department of Energy and the US Nuclear Regulatory Commission. The evaluation involved testing a representative cross section of instruments against criteria in the standard. This report presents results of the testing program. A brief history of the project is included in the introduction. The instrumentation tested is described in general terms (i.e., types, ranges); however, no direct relationship between the results and a specific instrument model is made in this report. Testing requirements in ANSI N42.17D4, Revision 1 (May 1985) are summarized and the methods by which the tests are performed are discussed. Brief descriptions of the testing equipment are included in the methods section of the report. More detailed information about the draft standard, testing requirements and procedures, and the test equipment is included in ''Performance Specifications for Health Physics Instrumentation - Portable Instrumentation for Use in Normal Work Environments, Part 1: Manual of Testing Procedures.'' Results of testing are given in two formats: test-by-test and instrument-by-instrument. Discussion is included on significant and interesting findings, on comparisons of results from the same type of instruments from same and different manufacturers, and on data grouped by manufacturer. Conclusions are made on the applicability and practicality of the proposed standard and on instrument performance. Changes that have been made to the proposed standard based on findings of the testing program are listed and discussed. 22 refs., 11 figs., 77 tabs

  19. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid ''P''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Report (ATR) provides the test results for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''P''. The ATR summaries the results and provides a copy of the ATP and inspections in the Appendix

  20. Test Report for Acceptance Test Procedure for Pumping Instrumentation and Control Skid Q

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Report (ATR) provides the test results for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''Q''. The ATR summaries the results and provides a copy of the ATP and inspections in the Appendix

  1. Temperature and pressure instrumentation in WWERs and their testing

    International Nuclear Information System (INIS)

    Por, G.

    1998-01-01

    A description of WWER model V-213 reactors of second generation is presented and compared to analogous NPPs including description of temperature and pressure instrumentation which was tested at Paks NPP. From the experimental results it was concluded that measured response of in core neutron detector to bubbles strongly depends on the relative position of detector and point bubble injection. Neutron noise spectra show characteristic sink when the origin of bubbles is close to the detectors. Dependence of phase behaviour on the boiling conditions is included as well

  2. Scaled Vitrification System III (SVS III) Process Development and Laboratory Tests at the West Valley Demonstration Project

    International Nuclear Information System (INIS)

    Jain, V.; Barnes, S.M.; Bindi, B.G.; Palmer, R.A.

    2000-01-01

    At the West Valley Demonstration Project (WVDP),the Vitrification Facility (VF)is designed to convert the high-level radioactive waste (HLW)stored on the site to a stable glass for disposal at a Department of Energy (DOE)-specified federal repository. The Scaled Vitrification System III (SVS-III)verification tests were conducted between February 1995 and August 1995 as a supplemental means to support the vitrification process flowsheet, but at only one seventh the scale.During these tests,the process flowsheet was refined and optimized. The SVS-III test series was conducted with a focus on confirming the applicability of the Redox Forecasting Model, which was based on the Index of Feed Oxidation (IFO)developed during the Functional and Checkout Testing of Systems (FACTS)and SVS-I tests. Additional goals were to investigate the prototypical feed preparation cycle and test the new target glass composition. Included in this report are the basis and current designs of the major components of the Scale Vitrification System and the results of the SVS-III tests.The major subsystems described are the feed preparation and delivery, melter, and off-gas treatment systems. In addition,the correlation between the melter's operation and its various parameters;which included feed rate,cold cap coverage,oxygen reduction (redox)state of the glass,melter power,plenum temperature,and airlift analysis;were developed

  3. Spirolit-2 instrument used to test pulmonary ventilation

    Science.gov (United States)

    Zhuravlev, V. V.

    1985-02-01

    At the present time, the Spirolit-2 automatic analyzer of main respiratory gases, of the Junkalor Dessau firm, is used to examine parameters of gas exchange, levels of energy expended by man and animals with different degrees of activity. However, the capabilities of this model of the instrument are limited. A method of determining pulmonary ventilation with use of the Spirolit-2 is described. An additional exhalation valve is built into a valve box to which an anesthesia machine rubber bag is attached. Samples are collected into another bag concurrently with the usual tests on the Spirolit-2 instrument. Four to five minutes are sufficient to obtain stable parameters at relative rest of oxygen uptake, determine carbon dioxide output per minute and collect samples in for analysis of exhaled air. The proposed method can furnish information about the dynamics of development of respiratory function of the lungs at virtually any moment with a constant physical load. For this, there must be spare bags to collect samples. Stage-by-stage data can be obtained analogously as to ventilation volume during a step test while determining maximum oxygen uptake.

  4. ORNL instrumentation performance for Slab Core Test Facility (SCTF)-Core I Reflood Test Facility

    International Nuclear Information System (INIS)

    Hardy, J.E.; Hess, R.A.; Hylton, J.O.

    1983-11-01

    Instrumentation was developed for making measurements in experimental refill-reflood test facilities. These unique instrumentation systems were designed to survive the severe environmental conditions that exist during a simulated pressurized water reactor loss-of-coolant accident (LOCA). Measurement of in-vessel fluid phenomena such as two-phase flow velocity and void fraction and film thickness and film velocity are required for better understanding of reactor behavior during LOCAs. The Advanced Instrumentation for Reflood Studies (AIRS) Program fabricated and delivered instrumentation systems and data reduction software algorithms that allowed the above measurements to be made. Data produced by AIRS sensors during three experimental runs in the Japanese Slab Core Test Facility are presented. Although many of the sensors failed before any useful data could be obtained, the remaining probes gave encouraging and useful results. These results are the first of their kind produced during simulated refill-reflood stage of a LOCA near actual thermohydrodynamic conditions

  5. Single specimen fracture toughness determination procedure using instrumented impact test

    International Nuclear Information System (INIS)

    Rintamaa, R.

    1993-04-01

    In the study a new single specimen test method and testing facility for evaluating dynamic fracture toughness has been developed. The method is based on the application of a new pendulum type instrumented impact tester equipped with and optical crack mouth opening displacement (COD) extensometer. The fracture toughness measurement technique uses the Double Displacement Ratio (DDR) method, which is based on the assumption that the specimen is deformed as two rigid arms that rotate around an apparent centre of rotation. This apparent moves as the crack grows, and the ratio of COD versus specimen displacement changes. As a consequence the onset ductile crack initiation can be detected on the load-displacement curve. Thus, an energy-based fracture toughness can be calculated. In addition the testing apparatus can use specimens with the Double ligament size as compared with the standard Charpy specimen which makes the impact testing more appropriate from the fracture mechanics point of view. The novel features of the testing facility and the feasibility of the new DDR method has been verified by performing an extensive experimental and analytical study. (99 refs., 91 figs., 27 tabs.)

  6. Enhanced in-pile instrumentation at the advanced test reactor

    Energy Technology Data Exchange (ETDEWEB)

    Rempe, J. L.; Knudson, D. L.; Daw, J. E.; Unruh, T.; Chase, B. M.; Palmer, J.; Condie, K. G.; Davis, K. L. [Idaho National Laboratory, MS 3840, P.O. Box 1625, Idaho Falls, ID 83415 (United States)

    2011-07-01

    Many of the sensors deployed at materials and test reactors cannot withstand the high flux/high temperature test conditions often requested by users at U.S. test reactors, such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory. To address this issue, an instrumentation development effort was initiated as part of the ATR National Scientific User Facility in 2007 to support the development and deployment of enhanced in-pile sensors. This paper reports results from this effort. Specifically, this paper identifies the types of sensors currently available to support in-pile irradiations and those sensors currently available to ATR users. Accomplishments from new sensor technology deployment efforts are highlighted by describing new temperature and thermal conductivity sensors now available to ATR users. Efforts to deploy enhanced in-pile sensors for detecting elongation and realtime flux detectors are also reported, and recently-initiated research to evaluate the viability of advanced technologies to provide enhanced accuracy for measuring key parameters during irradiation testing are noted. (authors)

  7. Enhanced In-Pile Instrumentation at the Advanced Test Reactor

    Science.gov (United States)

    Rempe, Joy L.; Knudson, Darrell L.; Daw, Joshua E.; Unruh, Troy; Chase, Benjamin M.; Palmer, Joe; Condie, Keith G.; Davis, Kurt L.

    2012-08-01

    Many of the sensors deployed at materials and test reactors cannot withstand the high flux/high temperature test conditions often requested by users at U.S. test reactors, such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory. To address this issue, an instrumentation development effort was initiated as part of the ATR National Scientific User Facility in 2007 to support the development and deployment of enhanced in-pile sensors. This paper provides an update on this effort. Specifically, this paper identifies the types of sensors currently available to support in-pile irradiations and those sensors currently available to ATR users. Accomplishments from new sensor technology deployment efforts are highlighted by describing new temperature and thermal conductivity sensors now available to ATR users. Efforts to deploy enhanced in-pile sensors for detecting elongation and real-time flux detectors are also reported, and recently-initiated research to evaluate the viability of advanced technologies to provide enhanced accuracy for measuring key parameters during irradiation testing are noted.

  8. Thermal vacuum test of space equipment: tests of SIR-2 instrument Chandrayaan-1 mission

    Science.gov (United States)

    Sitek, P.

    2008-11-01

    We describe the reasons of proceeding Thermal-Vacuum tests for space electronic. We will answer on following questions: why teams are doing TV tests, what kind of phases should be simulated, which situations are the most critical during TV tests, what kind of results should be expected, which errors can be detect. As an example, will be shown TV-test of SIR-2 instrument for Chandrayaan-1 moon mission.

  9. Development of the Test Of Astronomy STandards (TOAST) Assessment Instrument

    Science.gov (United States)

    Slater, Timothy F.; Slater, S. J.

    2008-05-01

    Considerable effort in the astronomy education research (AER) community over the past several years has focused on developing assessment tools in the form of multiple-choice conceptual diagnostics and content knowledge surveys. This has been critically important in advancing the AER discipline so that researchers could establish the initial knowledge state of students as well as to attempt measure some of the impacts of innovative instructional interventions. Unfortunately, few of the existing instruments were constructed upon a solid list of clearly articulated and widely agreed upon learning objectives. This was not done in oversight, but rather as a result of the relative youth of AER as a discipline. Now that several important science education reform documents exist and are generally accepted by the AER community, we are in a position to develop, validate, and disseminate a new assessment instrument which is tightly aligned to the consensus learning goals stated by the American Astronomical Society - Chair's Conference on ASTRO 101, the American Association of the Advancement of Science's Project 2061 Benchmarks, and the National Research Council's National Science Education Standards. In response, researchers from the Cognition in Astronomy, Physics and Earth sciences Research (CAPER) Team at the University of Wyoming's Science & Math Teaching Center (UWYO SMTC) have designed a criterion-referenced assessment tool, called the Test Of Astronomy STandards (TOAST). Through iterative development, this instrument has a high degree of reliability and validity for instructors and researchers needing information on students’ initial knowledge state at the beginning of a course and can be used, in aggregate, to help measure the impact of course-length duration instructional strategies for courses with learning goals tightly aligned to the consensus goals of our community.

  10. Production circulator fabrication and testing for core flow test loop. Final report, Phase III

    Energy Technology Data Exchange (ETDEWEB)

    1981-05-01

    The performance testing of two production helium circulators utilizing gas film lubrication is described. These two centrifugal-type circulators plus an identical circulator prototype will be arranged in series to provide the helium flow requirements for the Core Flow Test Loop which is part of the Gas-Cooled Fast Breeder Reactor Program (GCFR) at the Oak Ridge National Laboratory. This report presents the results of the Phase III performance and supplemental tests, which were carried out by MTI during the period of December 18, 1980 through March 19, 1981. Specific test procedures are outlined and described, as are individual tests for measuring the performance of the circulators. Test data and run descriptions are presented.

  11. Production circulator fabrication and testing for core flow test loop. Final report, Phase III

    International Nuclear Information System (INIS)

    1981-05-01

    The performance testing of two production helium circulators utilizing gas film lubrication is described. These two centrifugal-type circulators plus an identical circulator prototype will be arranged in series to provide the helium flow requirements for the Core Flow Test Loop which is part of the Gas-Cooled Fast Breeder Reactor Program (GCFR) at the Oak Ridge National Laboratory. This report presents the results of the Phase III performance and supplemental tests, which were carried out by MTI during the period of December 18, 1980 through March 19, 1981. Specific test procedures are outlined and described, as are individual tests for measuring the performance of the circulators. Test data and run descriptions are presented

  12. FMIT test-end instrumentation systems scoping study

    International Nuclear Information System (INIS)

    Fuller, J.L.; Dixon, N.E.; Sheen, E.M.

    1982-06-01

    For the Fusion Materials Irradiation Test facility (FMIT), the high power density of the accelerated deuteron beam and the unique nature of the liquid lithium target underscore the need for sensitive, fast and reliable test-end diagnostic instrumentation. The intense radiation environment in the test cell places severe limits on candidate systems, as to a lesser degree do thermal and lithium compatibility factors. A beam-target diagnostic station at 180 in the HEBT can facilitate source emission and spot-on-target imaging. Analyses support the feasibility of several candidate imaging systems. Incorporation of electromagnetic and electrostatic beam position detectors as part of the target assembly, as previously proposed, should also be feasible. The possibilities for on-line, real-time ultrasonic/acoustic target diagnosis are favorable. The use of redundant thermocouple and ion detector test assembly beam location detectors is also supported because of the possible problems with thermocouples in the intense 14-MeV neutron field and the simplicity of the ion detectors

  13. Gamma thermometer longevity test: Laguna Verde 2 instruments recent performance

    International Nuclear Information System (INIS)

    Cuevas V, G.; Avila N, A.; Calleros M, G.

    2013-10-01

    This paper is informative of the General Electric Hitachi and Global Nuclear Fuel - Americas are collaboration with Comision Federal de Electricidad in a longevity test of thermocouples as power monitoring devices. The test conclusions will serve for final engineering design in detailing the Automated Fixed In-core Probes for calibration of the Local Power Range Monitors (LPRMs) of the Economic Simplified Boiling Water Reactor. This paper introduces the collaboration description and some recent performance evaluation of the thermocouples that are sensitive to gamma radiation and are known generically as Gamma Thermometers (G T). The G Ts in Laguna Verde 2 are radially located inside six instrumentation tubes in the core and consist of seven thermocouples, four are aligned with the LPRM heights and three are axially located between LPRM heights. The Laguna Verde 2 G T test has become the longest test of thermocouples as power monitoring devices in a BWR industry history and confirms their reliability in terms of time-dependent small noise under steady state reactor conditions and good agreement against Traversing In-core Probes power measurements. (Author)

  14. Gamma thermometer longevity test: Laguna Verde 2 instruments recent performance

    Energy Technology Data Exchange (ETDEWEB)

    Cuevas V, G. [Global Nuclear Fuel, Americas, 3901 Castle Hayne Road, Wilmington, North Carolina (United States); Avila N, A.; Calleros M, G., E-mail: Gabriel.Cuevas-Vivas@gnf.com [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verda, Carretera Veracruz-Nautla Km 42.5, Alto Lucero, Veracruz (Mexico)

    2013-10-15

    This paper is informative of the General Electric Hitachi and Global Nuclear Fuel - Americas are collaboration with Comision Federal de Electricidad in a longevity test of thermocouples as power monitoring devices. The test conclusions will serve for final engineering design in detailing the Automated Fixed In-core Probes for calibration of the Local Power Range Monitors (LPRMs) of the Economic Simplified Boiling Water Reactor. This paper introduces the collaboration description and some recent performance evaluation of the thermocouples that are sensitive to gamma radiation and are known generically as Gamma Thermometers (G T). The G Ts in Laguna Verde 2 are radially located inside six instrumentation tubes in the core and consist of seven thermocouples, four are aligned with the LPRM heights and three are axially located between LPRM heights. The Laguna Verde 2 G T test has become the longest test of thermocouples as power monitoring devices in a BWR industry history and confirms their reliability in terms of time-dependent small noise under steady state reactor conditions and good agreement against Traversing In-core Probes power measurements. (Author)

  15. Vibration test report on the instrumented capsule for fuel irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Yoon, D. B.; Wu, J. S.; Oh, J. M.; Park, S. J.; Cho, M. S.; Kim, B. G.; Kang, Y. W

    2003-01-01

    The fluid-induced vibration level of instrumented capsule, which was manufactured for fuel irradiation test at the reactor core of HANARO, was investigated. For this purpose, the instrumented capsule was loaded at the OR site of the HANARO design verification test facility that could simulate identical flow condition as the HANARO core. Then, vibration signals of the instrumented capsule subjected to various flow conditions were measured by using vibration sensors. In time domain analysis, maximum amplitudes and RMS values of the measured acceleration and displacement signals were obtained. By using frequency domain analysis, frequency components of the fluid-induced vibration were analyzed. In addition, natural frequencies of the instrumented capsule were obtained by performing modal test. The frequency analysis results showed that the natural frequency components near 7.5Hz and 17.5Hz were dominant in the fluid-induced vibration signal. The maximum amplitude of the accelerations was measured as 12.04m/s{sup 2} that is within the allowable vibrational limit(18.99m/s{sup 2})of the reactor structure. Also, the maximum displacement amplitude was calculated as 0.191mm. Since these vibration levels are remarkably low, excessive vibration is not expected when the irradiation test of the instrumented capsule is performed at the HANARO core.

  16. D-Catch instrument : development and psychometric testing of a measurement instrument for nursing documentation in hospitals

    NARCIS (Netherlands)

    Paans, Wolter; Sermeus, Walter; Nieweg, Roos; van der Schans, Cees P.

    AIM: This paper is a report of the development and testing of the psychometric properties of an instrument to measure the accuracy of nursing documentation in general hospitals. BACKGROUND: Little information is available about the accuracy of nursing documentation. None of the existing instruments

  17. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  18. A Universal Motor Performance Test System Based on Virtual Instrument

    Directory of Open Access Journals (Sweden)

    Wei Li

    2014-09-01

    Full Text Available With the development of technology universal motors play a more and more important role in daily life and production, they have been used in increasingly wide field and the requirements increase gradually. How to control the speed and monitor the real-time temperature of motors are key issues. The cost of motor testing system based on traditional technology platform is very high in many reasons. In the paper a universal motor performance test system which based on virtual instrument is provided. The system achieves the precise control of the current motor speed and completes the measurement of real-time temperature of motor bearing support in order to realize the testing of general-purpose motor property. Experimental result shows that the system can work stability in controlling the speed and monitoring the real-time temperature. It has advantages that traditional using of SCM cannot match in speed, stability, cost and accuracy aspects. Besides it is easy to expand and reconfigure.

  19. Identification of Lanthanide(III) Luminophores in Magnetic Circularly Polarized Luminescence Using Raman Optical Activity Instrumentation

    Czech Academy of Sciences Publication Activity Database

    Wu, Tao; Kapitán, J.; Andrushchenko, Valery; Bouř, Petr

    2017-01-01

    Roč. 89, č. 9 (2017), s. 5043-5049 ISSN 0003-2700 R&D Projects: GA ČR(CZ) GJ16-08764Y; GA ČR GA15-09072S; GA ČR(CZ) GA16-05935S Institutional support: RVO:61388963 Keywords : rare earth ions * photophysical properties * europium(III) complexes Subject RIV: CF - Physical ; Theoretical Chemistry OBOR OECD: Physical chemistry Impact factor: 6.320, year: 2016

  20. Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance

    DEFF Research Database (Denmark)

    Poutanen, T.; Lähteenmäki, A.; León-Tavares, J.

    2011-01-01

    The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main...

  1. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2000-01-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised

  2. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  3. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  4. Eddy current testing system for bottom mounted instrumentation welds - 15206

    International Nuclear Information System (INIS)

    Kobayashi, N.; Ueno, S.; Suganuma, N.; Oodake, T.; Maehara, T.; Kasuya, T.; Ichikawa, H.

    2015-01-01

    We have demonstrated the scanning of eddy current testing (ECT) probe on the welds area including the nozzle, the J-welds and the buildup welds of the Bottom Mounted Instrumentation (BMI) mock-up using the developed ECT system and procedure. It is difficult to scan the probe on the BMI welds area because the area has a complex curved surface shape and narrow spaces. We made the space coordinates and the normal vectors on the scanning points as the scanning trajectory of probe on the welds area based on the measured results of welds surface shape on the mock-up. The multi-axis robot was used to scan the probe on the welds surface. Each motion axis position of the robot corresponding to each scanning point was calculated by the inverse kinematic algorithm. The BMI mock-up test was performed using the cross coil probe in the differential mode. The artificial stress corrosion cracking and the electrical discharge machining slits given on the mock-up surface were detected. The results show that the ECT can detect a defect of approximately 2.3 mm in length, 0.5 mm in depth and 0.2 mm in width for the BMI welds. From the output voltage of single coil, we estimated that the average and the maximum probe tilt angles on the mock-up surface under scanning were 2.6 degrees and 8.5 degrees, respectively

  5. Fabrication and Testing of Viscosity Measuring Instrument (Viscometer

    Directory of Open Access Journals (Sweden)

    A. B. HASSAN

    2006-01-01

    Full Text Available This paper presents the fabrication and testing of a simple and portable viscometer for the measurement of bulk viscosity of different Newtonian fluids. It is aimed at making available the instrument in local markets and consequently reducing or eliminating the prohibitive cost of importation. The method employed is the use of a D.C motor to rotate a disc having holes for infra-red light to pass through and fall on a photo-diode thus undergoing amplification and this signal being translated on a moving-coil meter as a deflection. The motor speed is kept constant but varies with changes in viscosity of the fluid during stirring, which alter signals being read on the meter. The faster is revolution per minute of the disc, the less the deflection on the meter and vise-versa. From the results of tests conducted on various sample fluids using data on standard Newtonian fluids as reliable guide the efficiency of the viscometer was 76.5%.

  6. Experimental Verification of an Instrument to Test Flooring Materials

    Science.gov (United States)

    Philip, Rony; Löfgren, Hans, Dr

    2018-02-01

    The focus of this work is to validate the fluid model with different flooring materials and the measurements of an instrument to test flooring materials and its force attenuating capabilities using mathematical models to describe the signature and coefficients of the floor. The main contribution of the present work focus on the development of a mathematical fluid model for floors. The aim of the thesis was to analyze, compare different floor materials and to study the linear dynamics of falling impacts on floors. The impact of the hammer during a fall is captured by an accelerometer and response is collected using a picoscope. The collected data was analyzed using matlab least square method which is coded as per the fluid model. The finding from this thesis showed that the fluid model works with more elastic model but it doesn’t work for rigid materials like wood. The importance of parameters like velocity, mass, energy loss and other coefficients of floor which influences the model during the impact of falling on floors were identified and a standardized testing method was set.

  7. Eddy current testing system for bottom mounted instrumentation welds

    Directory of Open Access Journals (Sweden)

    Kobayashi Noriyasu

    2015-01-01

    Full Text Available The capability of eddy current testing (ECT for the bottom mounted instrumentation (BMI weld area of reactor vessel in a pressurized water reactor was demonstrated by the developed ECT system and procedure. It is difficult to position and move the probe on the BMI weld area because the area has complexly curved surfaces. The space coordinates and the normal vectors at the scanning points were calculated as the scanning trajectory of probe based on the measured results of surface shape on the BMI mock-up. The multi-axis robot was used to move the probe on the mock-up. Each motion-axis position of the robot corresponding to each scanning point was calculated by the inverse kinematic algorithm. In the mock-up test, the probe was properly contacted with most of the weld surfaces. The artificial stress corrosion cracking of approximately 6 mm in length and the electrical-discharge machining slit of 0.5 mm in length, 1 mm in depth and 0.2 mm in width given on the weld surface were detected. From the probe output voltage, it was estimated that the average probe tilt angle on the surface under scanning was 2.6°.

  8. Sled Tests Using the Hybrid III Rail Safety ATD and Workstation Tables for Passenger Trains

    Science.gov (United States)

    2017-08-01

    The Hybrid III Rail Safety (H3-RS) anthropomorphic test device (ATD) is a crash test dummy developed in the United Kingdom to evaluate abdomen and lower thorax injuries that occur when passengers impact workstation tables during train accidents. The ...

  9. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  10. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  11. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2000-07-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised.

  12. Round robin tests of the PISC III programme on defective steam generators tubes

    International Nuclear Information System (INIS)

    Birac, C.; Herkenrath, H.; Crutzen, S.; Miyake, Y.; Maciga, G.

    1991-11-01

    The PISC III actions are intended to extend the results and methodologies of the previous PISC exercises, i.e. the assessment of the capabilities of the various examination techniques when used on real or realistic flaws in real components under real conditions of inspection. Being aware of the industrial problems that the degradation of steam generator tubes can create, the PISC III management board decided to include in the PISC III programme a special action on steam generator tubes testing (SGT). (author)

  13. Femoral Test Bed for Impedance Controlled Surgical Instrumentation

    Directory of Open Access Journals (Sweden)

    Christian Brendle

    2012-01-01

    Full Text Available The risk for patients during the standard procedure of revision of cemented artificial hip joints is unsatisfactorily highdue to its high level of invasiveness and limited access to the operative field. To reduce this risk we are developing anImpedance Controlled Surgical Instrumentation (ICOS system, which aims to establish real-time control during a BoneCement (BC milling process. For this, the relationship between the thickness of the BC and its frequency-dependentelectrical impedance is used to estimate the residual BC thickness. The aim is to avoid unintended cutting of boneby detecting the passage of the BC/bone boundary layer by the milling head. In a second step, an estimation of theresidual BC thickness will be used to improve process control. As a first step towards demonstrating the feasibility ofour approach, presented here are experimental studies to characterize the BC permittivity and to describe the process indetail. The results show that the permittivity properties of BC are dominated by its polymethyl methacrylate (PMMAfraction. Thus, PMMA can be used as a substitute for future experiments. Furthermore, a Femoral Test Bed (FTB wasdesigned. Using this setup we show it is feasible to accurately distinguish between slightly different thicknesses of BC.

  14. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  15. Sodium-NaK engineering handbook. Volume III. Sodium systems, safety, handling, and instrumentation. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Foust, O J [ed.

    1978-01-01

    The handbook is intended for use by present and future designers in the Liquid Metals Fast Breeder Reactor (LMFBR) Program and by the engineering and scientific community performing other type investigation and exprimentation requiring high-temperature sodium and NaK technology. The arrangement of subject matter progresses from a technological discussion of sodium and sodium--potassium alloy (NaK) to discussions of varius categories and uses of hardware in sodium and NaK systems. Emphasis is placed on sodium and NaK as heat-transport media. Sufficient detail is included for basic understanding of sodium and NaK technology and of technical aspects of sodium and NaK components and instrument systems. Information presented is considered adequate for use in feasibility studies and conceptual design, sizing components and systems, developing preliminary component and system descriptions, identifying technological limitations and problem areas, and defining basic constraints and parameters.

  16. Instruments

    International Nuclear Information System (INIS)

    Buehrer, W.

    1996-01-01

    The present paper mediates a basic knowledge of the most commonly used experimental techniques. We discuss the principles and concepts necessary to understand what one is doing if one performs an experiment on a certain instrument. (author) 29 figs., 1 tab., refs

  17. 47 CFR 2.1505 - Test instrumentation and equipment.

    Science.gov (United States)

    2010-10-01

    ... instrument is to be DC coupled and capable of manually triggered single sweeps. (d) Frequency counter. A... frequency. (e) Signal generator. A calibrated signal generator with an output of at least 75 mW at 121.5 and...

  18. Organizational learning, pilot test of Likert-type instruments

    Directory of Open Access Journals (Sweden)

    Manuel Alfonso Garzón Castrillón

    2010-09-01

    Full Text Available This paper presents the results obtained in the pilot study of instruments created to comply the specific objective of designing and validating instruments to study the capacity of organizational learning. The Likert measurement scale was used because it allowed to establish the pertinence of the dimension as variable in the context of organizational learning. A One-way Analysis of Variance (ANOVA was used, with statistical package SPSS. Some 138 variables in 3 factors and 40 affirmations were simplified.

  19. 49 CFR 572.155 - Test conditions and instrumentation.

    Science.gov (United States)

    2010-10-01

    ... in triaxial configuration as shown in drawing 921022-000. (f) The lumbar spine and lower neck force... classes as follows: (1) Head and headform acceleration—Class 1000. (2) Neck : (i) Forces—Class 1000; (ii) Moments—Class 600; (iii) Pendulum acceleration—Class 180; (iv) Rotation potentiometer response (if used...

  20. 49 CFR 572.146 - Test conditions and instrumentation.

    Science.gov (United States)

    2010-10-01

    ... transducer location as shown in drawing 210-0000. A lower neck transducer as specified in drawing SA 572-S19...) Head acceleration—Class 1000 (2) Neck (i) Force—Class 1000 (ii) Moments—Class 600 (iii) Pendulum acceleration—Class 180 (iv) Rotation potentiometer response (if used)—CFC 60. (3) Thorax: (i) Rib/sternum...

  1. Instrumentation

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.G.

    1982-01-01

    This chapter reviews the parameters which are important to positron-imaging instruments. It summarizes the options which various groups have explored in designing tomographs and the methods which have been developed to overcome some of the limitations inherent in the technique as well as in present instruments. The chapter is not presented as a defense of positron imaging versus single-photon or other imaging modality, neither does it contain a description of various existing instruments, but rather stresses their common properties and problems. Design parameters which are considered are resolution, sampling requirements, sensitivity, methods of eliminating scattered radiation, random coincidences and attenuation. The implementation of these parameters is considered, with special reference to sampling, choice of detector material, detector ring diameter and shielding and variations in point spread function. Quantitation problems discussed are normalization, and attenuation and random corrections. Present developments mentioned are noise reduction through time-of-flight-assisted tomography and signal to noise improvements through high intrinsic resolution. Extensive bibliography. (U.K.)

  2. Peabody Picture Vocabulary Test (PPVT-III: Psychometric properties and significance for application

    Directory of Open Access Journals (Sweden)

    Nataša Bucik

    2003-12-01

    Full Text Available The purpose of this article is to present the content, conceptual structure and methodological steps of the latest revision of the Peabody Picture Vocabulary Test (PPVT-III, which is a highly functional and valuable vocabulary test that has been in use since 1959 in different language and cultural surroundings. On the case of the PPVT-III we are presenting the procedure of development and standardization of such vocabulary tests as well as its translation and adaptation from one language and cultural milieu to another. We also note the practical use of the PPVT-III for research purposes. In Slovenian language no vocabulary tests were developed or adapted so far; PPVT-III is presented in this context, too.

  3. Construction Of Critical Thinking Skills Test Instrument Related The Concept On Sound Wave

    Science.gov (United States)

    Mabruroh, F.; Suhandi, A.

    2017-02-01

    This study aimed to construct test instrument of critical thinking skills of high school students related the concept on sound wave. This research using a mixed methods with sequential exploratory design, consists of: 1) a preliminary study; 2) design and review of test instruments. The form of test instruments in essay questions, consist of 18 questions that was divided into 5 indicators and 8 sub-indicators of the critical thinking skills expressed by Ennis, with questions that are qualitative and contextual. Phases of preliminary study include: a) policy studies; b) survey to the school; c) and literature studies. Phases of the design and review of test instruments consist of two steps, namely a draft design of test instruments include: a) analysis of the depth of teaching materials; b) the selection of indicators and sub-indicators of critical thinking skills; c) analysis of indicators and sub-indicators of critical thinking skills; d) implementation of indicators and sub-indicators of critical thinking skills; and e) making the descriptions about the test instrument. In the next phase of the review test instruments, consist of: a) writing about the test instrument; b) validity test by experts; and c) revision of test instruments based on the validator.

  4. Comparison between instrumented precracked Charpy and compact specimen tests of carbon steels

    International Nuclear Information System (INIS)

    Nanstad, R.K.

    1980-01-01

    The General Atomic Company High Temperature Gas-Cooled Reactor (HTGR) is housed within a prestressed concrete reactor vessel (PCRV). Various carbon steel structural members serve as closures at penetrations in the vessel. A program of testing and evaluation is underway to determine the need for reference fracture toughness (K/sub IR/) and indexing procedures for these materials as described in Appendix G to Section III, ASME Code for light water reactor steels. The materials of interest are carbon steel forgings (SA508, Class 1) and plates (SA537, Classes 1 and 2) as well as weldments of these steels. The fracture toughness behavior is characterized with instrumented precracked Charpy V-votch specimens (PCVN) - slow-bend and dynamic - and compact specimens (10-mm and 25-mm thicknesses) using both linear elastic (ASTM E399) and elastic-plastic (equivalent Energy and J-Integral) analytical procedures. For the dynamic PCVN tests, force-time traces are analyzed according to the procedures of the Pressure Vessel Research Council (PVRC)/Metal Properties Council (MPC). Testing and analytical procedures are discussed and PCVN results are compared to those obtained with compact specimens

  5. LITERATURE CURRICULUM III--TEST FOR "THE MERCHANT OF VENICE."

    Science.gov (United States)

    KITZHABER, ALBERT R.

    THIS TEST--"THE MERCHANT OF VENICE"--WAS DESIGNED BY THE OREGON CURRICULUM STUDY CENTER FOR A NINTH-GRADE LITERATURE CURRICULUM. IT IS INTENDED TO ACCOMPANY CURRICULUM UNITS AVAILABLE AS ED 010 815 AND ED 010 816. (MM)

  6. Validation of the Serpent 2-DYNSUB code sequence using the Special Power Excursion Reactor Test III (SPERT III)

    International Nuclear Information System (INIS)

    Knebel, Miriam; Mercatali, Luigi; Sanchez, Victor; Stieglitz, Robert; Macian-Juan, Rafael

    2016-01-01

    Highlights: • Full few-group cross section tables created by Monte Carlo lattice code Serpent 2. • Serpent 2 group constant methodology verified for HFP static and transient cases. • Serpent 2-DYNSUB tool chainvalidated using SPERT III REA experiments. • Serpent 2-DYNSUB tool chain suitable to model RIAs in PWRs. - Abstract: The Special Power Excursion Reactor Test III (SPERT III) is studied using the Serpent 2-DYNSUB code sequence in order to validate it for modeling reactivity insertion accidents (RIA) in PWRs. The SPERT III E-core was a thermal research reactor constructed to analyze reactor dynamics. Its configuration resembles a commercial PWR on terms of fuel type, choice of moderator, coolant flow and system pressure. The initial conditions of the rod ejection accident experiments (REA) performed cover cold startup, hot startup, hot standby and operating power scenarios. Eight of these experiments were analyzed in detail. Firstly, multi-dimensional nodal diffusion cross section tables were created for the three-dimensional reactor simulator DYNSUB employing the Monte Carlo neutron transport code Serpent 2. In a second step, DYNSUB stationary simulations were compared to Monte Carlo reference three-dimensional full scale solutions obtained with Serpent 2 (cold startup conditions) and Serpent 2/SUBCHANFLOW (operating power conditions) with a good agreement being observed. The latter tool is an internal coupling of Serpent 2 and the sub-channel thermal-hydraulics code SUBCHANFLOW. Finally, DYNSUB was utilized to study the eight selected transient experiments. Results were found to match measurements well. As the selected experiments cover much of the possible transient (delayed super-critical, prompt super-critical and super-prompt critical excursion) and initial conditions (cold and hot as well as zero, little and full power reactor states) one expects in commercial PWRs, the obtained results give confidence that the Serpent 2-DYNSUB tool chain is

  7. Results of the initial test program for the Sandia Pulsed Reactor III (SPR III)

    International Nuclear Information System (INIS)

    Estes, B.F.; Reuscher, J.A.

    1976-08-01

    This document presents a detailed discussion of the reactor including the mechanical and nuclear design characteristics. Also presented are the complete results of the Initial Approach to Critical and the Zero-and-Low Power testing programs. Reactivity worth measurements are given for such parameters as control element integral worth, Safety Block integral worth, and various materials (polyethylene, copper, lead, etc) as a function of position relative to the core. Subcritical reactivity measurements made during the approach to critical generally proved to be in reasonably good agreement with design values due to the good source-fuel-detector geometry possible with a reactor of this type. Subsequent dynamic measurements for reactivity worths are shown to be in good agreement with calculated results

  8. 49 CFR 572.137 - Test conditions and instrumentation.

    Science.gov (United States)

    2010-10-01

    ...-S15 and be mounted in the lower torso assembly as shown in drawing 880105-450. (g) The optional iliac... assembly as shown in drawings 880105-300 and 880105-000 sheet 3 of 6. (k) The optional lower neck force...—Class 1000 (2) Neck: (i) Forces—Class 1000 (ii) Moments—Class 600 (iii) Pendulum acceleration—Class 180...

  9. 'Test Driving' a Financing Instrument for Climate Adaptation

    NARCIS (Netherlands)

    Root, Liz; Krabben, van der Erwin; Spit, Tejo

    2016-01-01

    Urban physical public infrastructure is a frontline defense mechanism to manage and mitigate climate-related impacts. Market instruments are often cited as possible means to spread risk and reduce financial burdens on the public sector. The authors argue that existing research tends to focus on the

  10. Making System Dynamics Cool III : New Hot Teaching & Testing Cases

    NARCIS (Netherlands)

    Pruyt, E.

    2011-01-01

    This follow-up paper presents seven actual cases for testing and teaching System Dynamics developed and used between January 2010 and January 2011 for one of the largest System Dynamics courses (250+ students per year) at Delft University of Technology in the Netherlands. The cases presented in this

  11. Phase III (full scale) agitated mixing test plan

    International Nuclear Information System (INIS)

    Ruff, D.T.

    1994-01-01

    Waste Receiving and Processing Facility Module 2A (WRAP 2A) is the proposed second module of the WRAP facility. This facility will provide the required treatment for contact Handled (CH) Low Level (LL) Mixed Waste (MW) to allow its permanent disposal. Solidification of a portion of this waste using a cement based grout has been selected in order to reduce the toxicity and mobility of the waste in the disposal site. Mixing of the waste with the cement paste and material handling constraints/requirements associated with the mixed material is, therefore, a key process in the overall treatment strategy. This test plan addresses Phase 3, Full Scale Testing. The objectives of these tests are to determine if there are scale-up issues associated with the mixing results obtained in Phase 1 and 2 mixing tests, verify the workability of mixtures resulting from previous formulation development efforts (Waste Immobilization Development [WID]), and provide a baseline for WRAP 2A mixing equipment design. To this end, the following objectives are of particular interest: determine geometric influence of mixing blade at full scale (i.e., size, type, and location: height/offset); determine if similar results in terms of mixing effectiveness and product quality are achievable at this scale; determine if vibration is as effective at this larger scale in fluidizing the mixture and aiding in cleaning the vessel; determine if baffles or sweeping blades are needed to aid in mixing at the larger size and for cleaning the vessel; and determine quality of the poured monolithic product and investigate exotherm and filling influences at this larger size

  12. Thermal architecture design tests for the Planck/HFI instrument

    Energy Technology Data Exchange (ETDEWEB)

    Piat, M.; Leriche, B.; Torre, J.-P.; Lamarre, J.-M.; Benoit, A.; Crussaire, J.-P

    2000-04-07

    The ESA satellite project Planck is designed to survey the sky at sub-millimetre and millimetre wavelengths in a drift scan mode. The High-Frequency Instrument (HFI) will use 48 bolometers cooled to 100 mK by a dilution cooler. In this paper, we describe how the scan strategy leads to requirements on the 0.1 K stage temperature stability and how a combination of a passive and an active system can be used to approach this specification.

  13. Detailed technical plan for Test Program Element-III (TPE-III) of the first wall/blanket shield engineering test program

    International Nuclear Information System (INIS)

    Turner, L.R.; Praeg, W.F.

    1982-03-01

    The experimental requirements, test-bed design, and computational requirements are reviewed and updated. Next, in Sections 3, 4 and 5, the experimental plan, instrumentation, and computer plan, respectively, are described. Finally, Section 6 treats other considerations, such as personnel, outside participation, and distribution of results

  14. Detailed technical plan for Test Program Element-III (TPE-III) of the first wall/blanket shield engineering test program

    Energy Technology Data Exchange (ETDEWEB)

    Turner, L.R.; Praeg, W.F.

    1982-03-01

    The experimental requirements, test-bed design, and computational requirements are reviewed and updated. Next, in Sections 3, 4 and 5, the experimental plan, instrumentation, and computer plan, respectively, are described. Finally, Section 6 treats other considerations, such as personnel, outside participation, and distribution of results.

  15. Fabrication of Non-instrumented capsule for DUPIC simulated fuel irradiation test in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B.G.; Kang, Y.H.; Park, S.J.; Shin, Y.T. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-10-01

    In order to develope DUPIC nuclear fuel, the irradiation test for simulated DUPIC fuel was planed using a non-instrumented capsule in HANARO. Because DUPIC fuel is highly radioactive material the non-instrumented capsule for an irradiation test of simulated DUPIC fuel in HANARO was designed to remotely assemble and disassemble in hot cell. And then, according to the design requirements the non-instrumented DUPIC capsule was successfully manufactured. Also, the manufacturing technologies of the non-instrumented capsule for irradiating the nuclear fuel in HANARO were established, and the basic technology for the development of the instrumented capsule technology was accumulated. This report describes the manufacturing of the non-instrumented capsule for simulated DUPIC fuel. And, this report will be based to develope the instrumented capsule, which will be utilized to irradiate the nuclear fuel in HANARO. 26 refs., 4 figs. (Author)

  16. Test instruments used by Journal of Music Therapy authors from 1984-1997.

    Science.gov (United States)

    Gregory, D

    2000-01-01

    Issues of the Journal of Music Therapy from 1984 to 1997 were selected to investigate the application of test instruments in music therapy research. All experimental and descriptive research articles were reviewed to determine if the methodology included test instruments. Other types of measurements-physiological measures, behavioral observations, computerized devices, and self-reports were excluded from the analysis. Test instruments were categorized as either published, unpublished, or researcher-constructed. A test instrument was "published" if, after a search in the "Test Review Locator" of the Buros Mental Measurements Web Site, a reference was found in one or more of the following publications-Mental Measurement Yearbooks, Tests in Print, or Test Critiques. A test was categorized as "unpublished" if the developer was cited in the JMT article but the test was not located in one or more of the above publications. All other test instruments were categorized as researcher-constructed tests designed for the specific study in the article. From 1984-1997, 220 articles were published in JMT. Approximately 83% (n = 183) of the total were experimental or descriptive research studies. Of the 183 articles research studies, 92 (50%) included a test instrument. Reviews of method sections of the 92 articles resulted in a listing of 115 different test instruments. Percentages of researcher-constructed tests, unpublished tests, and published tests were 25%, 35%, and 40% respectively. Lists of tests document the all-encompassing range of client populations and the broad view of human behavior included in the practice of music as therapy. The Journal of Music Therapy, in addition to providing the latest research findings regarding the effectiveness of music as a therapeutic medium, provides an excellent source for updating information about the availability and applicability of test instruments for music therapy clinical practice and training.

  17. DAS: A Data Management System for Instrument Tests and Operations

    Science.gov (United States)

    Frailis, M.; Sartor, S.; Zacchei, A.; Lodi, M.; Cirami, R.; Pasian, F.; Trifoglio, M.; Bulgarelli, A.; Gianotti, F.; Franceschi, E.; Nicastro, L.; Conforti, V.; Zoli, A.; Smart, R.; Morbidelli, R.; Dadina, M.

    2014-05-01

    The Data Access System (DAS) is a and data management software system, providing a reusable solution for the storage of data acquired both from telescopes and auxiliary data sources during the instrument development phases and operations. It is part of the Customizable Instrument WorkStation system (CIWS-FW), a framework for the storage, processing and quick-look at the data acquired from scientific instruments. The DAS provides a data access layer mainly targeted to software applications: quick-look displays, pre-processing pipelines and scientific workflows. It is logically organized in three main components: an intuitive and compact Data Definition Language (DAS DDL) in XML format, aimed for user-defined data types; an Application Programming Interface (DAS API), automatically adding classes and methods supporting the DDL data types, and providing an object-oriented query language; a data management component, which maps the metadata of the DDL data types in a relational Data Base Management System (DBMS), and stores the data in a shared (network) file system. With the DAS DDL, developers define the data model for a particular project, specifying for each data type the metadata attributes, the data format and layout (if applicable), and named references to related or aggregated data types. Together with the DDL user-defined data types, the DAS API acts as the only interface to store, query and retrieve the metadata and data in the DAS system, providing both an abstract interface and a data model specific one in C, C++ and Python. The mapping of metadata in the back-end database is automatic and supports several relational DBMSs, including MySQL, Oracle and PostgreSQL.

  18. Acceptance Test Procedure for New Pumping and Instrumentation Control Skid L

    International Nuclear Information System (INIS)

    KOCH, M.R.

    1999-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping and Instrumentation Control (PIC) skid designed as ''L''. The ATP will be performed after the construction of the PIC skid in the shop

  19. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''P''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''P''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  20. Acceptance Test Procedure for New Pumping and Instrumentation Control Skid N

    International Nuclear Information System (INIS)

    KOCH, M.R.

    1999-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping and Instrumentation Control (PIC) skid designed as ''N''. The ATP will be performed after the construction of the PIC skid in the shop

  1. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid W

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''W''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  2. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid V

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control. (PIC) skid designed as ''V''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  3. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''V''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designated as ''V''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  4. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''Q''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''Q''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  5. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''T''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designated as ''T''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  6. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid T

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing Of the new Pumping Instrumentation and Control (PIC) skid designed as ''T''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  7. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid R

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''R''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  8. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''U''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) provides for the inspection and testing of the new Pumping Instrumentation and Control (PIC) skid designed as ''U''. The ATP will be performed after the construction of the PIC skid in the fabrication shop

  9. Automated testing of reactor protection instrumentation made easy

    International Nuclear Information System (INIS)

    Iborra, A.; De Marcos, F.; Pastor, J.A.; Alvarez, B.; Jimenez, A.; Mesa, E.; Alsonso, L.; Regidor, J.J.

    1997-01-01

    Maintenance and testing of reactor protection systems is an important cause of unplanned reactor trips. Automated testing is the answer because it minimises test times and reduces human error. The GAMA I system, developed and implemented at Vandellos II in Spain, has the added advantage that it uses visual programming, which means that changing the software does not need specialist programming skills. (author)

  10. Specialist committee's review reports for experimental fast reactor JOYO' MK-III performance tests

    International Nuclear Information System (INIS)

    Yamashita, Kiyonobu; Okubo, Toshiyuki; Kamide, Hideki

    2004-02-01

    Performance tests (startup-physics tests and power elevation tests) were planed for experimental fast reactor 'JOYO' MK-III where irradiation performances were upgraded by power increase from 100 to 140 MW. The reactor safety committee of O-arai Engineering Center has established a specialist committee for 'JOYO' MK-III Performance Tests at the first meeting of 2003 on 23th. April 2003, to accomplish the tests successfully. Subjects of the specialist committee were reviews of following items covering a wide range. 1) Contents of modification works. 2) Reflections of functional test results to the plant and facilities. 3) Reflections of safety rule modification to instruction and manual for operation. 4) Quality assurances and pre-calculation for performance test. 5) Inspection plan and its results. 6) Adequacy of performance test plan. 7) Confirmation of performance test results. Before test-starts, the specialist committee has confirmed by reviewing the items from 1) to 6) based on explanations and documents of the Division of Experimental Reactor, that the test plan and pre-inspections are adequate. After the tests, the specialist committee had confirmed by reviewing the item 7) in the same way, that the each test result satisfies the corresponding criterion. The specialist committee has concluded from these review's results before and after the tests that the 'JOYO' MK-III Performance Tests were carried out appropriately. Besides, the first criticality of the JOYO MK-III was achieved on 2nd. July 2003, and the continuous full power operation was carried on 20th. Nov. 2003. Finally, all performance tests were completed by the pass of the last governmental pre-serviced inspection (dose rate measurement during the shut down condition). (author)

  11. Instrument performance in bone density testing at five Australian centres

    Energy Technology Data Exchange (ETDEWEB)

    Khan, K M; Saul, A; Wark, J D [Royal Melbourne Hospital, Parkville, VIC (Australia). Department of Medicine; Henzell, S L [Charles Gairdner Hospital, Perth, WA (Australia). Department of Endocrinology and Diabetes; Broderick, C [University of NSW, Sydney, NSW (Australia); Prince, R L [University of Western Australia, Perth, WA. (Australia). Department of Medicine; Lomman, J [Bone Densitometry Technologist, Ashford, SA (Australia)

    1997-10-01

    Using a multicentre reliability study the accuracy and short- and long-term precision of dual-energy X-ray absorptiometry (DXA) in vitro was compared on five instruments. Measures were performed using pencil beam mode on four Hologic QDR- 2000 densitometers and one Hologic QDR-1000/W (Hologic Inc, Waltham, MA). Short-term precision of bone mineral density measurement was less than 0.5% for spine phantoms (n= 10 for each centre, mean intrasite coefficient of variation [CV] 0.39{+-}0.09% [SD]) and for hip phantoms (n=10 for each centre, mean intrasite coefficient of variation [CV] 0.34{+-}0.10% [SD]). Between-centre measurement (n=10 for each phantom) of a single spine phantom and a single hip phantom (specified mineral contents - 58.5 g and 38.6 g, respectively) revealed ranges of bone mineral content of 57.7-58.1 g (all-point CV=0.52%) and 37.1-37.8 g (all-point CV=0.70%), respectively. When results from pairs of machines were compared there were statistically different mean BMD results for the majority of the ten possible pairings for both spine and hip measurements. Each study centre measured in vitro stability of phantom BMD measurements over a one year period (n=45-283, median 157 for spine; and n=0-262, median 38, for hip); CVs ranged from 0.38 % to 0.53% for the spine measurements and from 0.38 % to 0.54% for the hip measurements. The mean all-point accuracy of the spine phantom measurements was 99.1% and the hip phantom measurements was 96.7%. It is concluded that across a number of instruments assessed in this study, DXA demonstrates in vitro all-point precision of 0.5% for the spine phantom and 0.7% for the hip phantom. The instrument demonstrates accuracy of greater than 99% at the spine and 96% at the hip (authors). 14 refs., 3 tabs., 4 figs.

  12. Ares I Scale Model Acoustic Tests Instrumentation for Acoustic and Pressure Measurements

    Science.gov (United States)

    Vargas, Magda B.; Counter, Douglas D.

    2011-01-01

    The Ares I Scale Model Acoustic Test (ASMAT) was a development test performed at the Marshall Space Flight Center (MSFC) East Test Area (ETA) Test Stand 116. The test article included a 5% scale Ares I vehicle model and tower mounted on the Mobile Launcher. Acoustic and pressure data were measured by approximately 200 instruments located throughout the test article. There were four primary ASMAT instrument suites: ignition overpressure (IOP), lift-off acoustics (LOA), ground acoustics (GA), and spatial correlation (SC). Each instrumentation suite incorporated different sensor models which were selected based upon measurement requirements. These requirements included the type of measurement, exposure to the environment, instrumentation check-outs and data acquisition. The sensors were attached to the test article using different mounts and brackets dependent upon the location of the sensor. This presentation addresses the observed effect of the sensors and mounts on the acoustic and pressure measurements.

  13. Testing electrical insulation of LCT coils and instrumentation

    International Nuclear Information System (INIS)

    Luton, J.N.; Ulbricht, A.R.; Ellis, J.F.; Shen, S.S.; Wilson, C.T.; Okuno, K.; Siewerdt, L.O.; Zahn, G.R.; Zichy, J.A.

    1986-09-01

    Three of the superconducting test coils in the Large Coil Task (LCT) use conductors cooled internally by forced flow of helium. In the other three coils, the conductors are cooled externally by a bath of helium. The coils and facility are designed for rapid discharges (dumps) at voltages up to 2.5 kV, depending on coil design. Many coil sensors are connected electrically to the conductors. These sensor leads and signal conditioning equipment also experience high voltage. High-potential tests of ground insulation were performed on all components of the International Fusion Superconducting Magnet Test Facility (IFSMTF). Coil insulation was also tested by ring-down tests that produced voltage distributions within the coils like those occurring during rapid discharge. Methods were developed to localize problem areas and to eliminate them. The effect on breakdown voltage near the Paschen minimum of magnetic fields up to 2 T was investigated

  14. Impact of proof test interval and coverage on probability of failure of safety instrumented function

    International Nuclear Information System (INIS)

    Jin, Jianghong; Pang, Lei; Hu, Bin; Wang, Xiaodong

    2016-01-01

    Highlights: • Introduction of proof test coverage makes the calculation of the probability of failure for SIF more accurate. • The probability of failure undetected by proof test is independently defined as P TIF and calculated. • P TIF is quantified using reliability block diagram and simple formula of PFD avg . • Improving proof test coverage and adopting reasonable test period can reduce the probability of failure for SIF. - Abstract: Imperfection of proof test can result in the safety function failure of safety instrumented system (SIS) at any time in its life period. IEC61508 and other references ignored or only elementarily analyzed the imperfection of proof test. In order to further study the impact of the imperfection of proof test on the probability of failure for safety instrumented function (SIF), the necessity of proof test and influence of its imperfection on system performance was first analyzed theoretically. The probability of failure for safety instrumented function resulted from the imperfection of proof test was defined as probability of test independent failures (P TIF ), and P TIF was separately calculated by introducing proof test coverage and adopting reliability block diagram, with reference to the simplified calculation formula of average probability of failure on demand (PFD avg ). Research results show that: the shorter proof test period and the higher proof test coverage indicate the smaller probability of failure for safety instrumented function. The probability of failure for safety instrumented function which is calculated by introducing proof test coverage will be more accurate.

  15. Cryogenic test facility instrumentation with fiber optic and fiber optic sensors for testing superconducting accelerator magnets

    Science.gov (United States)

    Chiuchiolo, A.; Bajas, H.; Bajko, M.; Castaldo, B.; Consales, M.; Cusano, A.; Giordano, M.; Giloux, C.; Perez, J. C.; Sansone, L.; Viret, P.

    2017-12-01

    The magnets for the next steps in accelerator physics, such as the High Luminosity upgrade of the LHC (HL- LHC) and the Future Circular Collider (FCC), require the development of new technologies for manufacturing and monitoring. To meet the HL-LHC new requirements, a large upgrade of the CERN SM18 cryogenic test facilities is ongoing with the implementation of new cryostats and cryogenic instrumentation. The paper deals with the advances in the development and the calibration of fiber optic sensors in the range 300 - 4 K using a dedicated closed-cycle refrigerator system composed of a pulse tube and a cryogen-free cryostat. The calibrated fiber optic sensors (FOS) have been installed in three vertical cryostats used for testing superconducting magnets down to 1.9 K or 4.2 K and in the variable temperature test bench (100 - 4.2 K). Some examples of FOS measurements of cryostat temperature evolution are presented as well as measurements of strain performed on a subscale of High Temperature Superconducting magnet during its powering tests.

  16. Modern instrumentation for radiation introscopic testing of welding quality

    International Nuclear Information System (INIS)

    Sosnin, F.R.

    1985-01-01

    Modern instrumenlation used for radiation introscopy of welded joints is discussed. the absolute (relative) sensitivity of radiation testing, resolution range, efficiency are considered as basic parameters of introscopes. The characteristics of fluoroscopes, radiation-television installations with the external scintillator and radiative image converter as well as with X-ray vidicons are given. The characterisitcs of radiation introscopes with manipulators to move objects being tested are analysed as well as digitized radiation introscopes

  17. Comparisons of ROSA-III and FIST BWR loss of coolant accident simulation tests

    International Nuclear Information System (INIS)

    Tasaka, Kanji; Suzuki, Mitsuhiro; Koizumi, Yasuo

    1985-10-01

    A common understanding and interpretation of BWR system response and the controlling phenomena in LOCA transients has been achieved through the evaluation and comparison of counterpart tests performed in the ROSA-III and FIST test facilities. These facilities, which are designed to simulate the thermal-hydraulic response of BWR systems, are operated respectively by the Japan Atomic Energy Research Institute (JAERI) and the General Electric Company. Comparison is made between three types of counterpart tests, each performed under similar tests conditions in the two facilities. They are large break, small break, and steamline break LOCA's. The system responses to these tests in each facility are quite similar. The sequence of events are similar, and the timing of these events are similar. Differences that do occur are due to minor differences in modeling objectives, facility scaling, and test conditions. Parallel channel flow interactions effects in the ROSA-III four channel (half length) core, although noticeable in the large break test, do not result in major differences with the single channel response in FIST. In the small break tests the timing of events is offset by the earlier ADS actuation in FIST. The steamline test responses are similar except there is no heatup in FIST, resulting from a different ECCS trip modeling. Overall comparisons between ROSA-III and FIST system responses in LOCA tests is very good. (author)

  18. WATCH: Warwick Assessment insTrument for Clinical teacHing: Development and testing.

    Science.gov (United States)

    Haider, Sonia Ijaz; Johnson, Neil; Thistlethwaite, Jill Elizabeth; Fagan, Gay; Bari, Muhammad Furqan

    2015-03-01

    Medical education and teaching skills are core competencies included in the generic curriculum for specialty training. To support the development of these skills, there is need for a validated instrument. This study aims to develop and test an instrument to measure the attributes of specialty trainees as effective teachers. The study was conducted in two phases. In first phase, the content of the instrument was generated from the literature and tested using the Delphi technique. In second phase, the instrument was field tested for validity and reliability using factor analysis and generalizability study. Feasibility was calculated by the time taken to complete the instrument. Acceptability and educational impact were determined by qualitative analysis of written feedback. Attributes of specialty trainees were assessed by clinical supervisors, peers, and students. The Delphi study produced consensus on 15 statements which formed the basis of the instrument. In field study, a total of 415 instruments were completed. Factor analysis demonstrated a three-factor solution ('learning-teaching milieu', 'teaching skills', and 'learner-orientated'). A generalizability coefficient was 0.92. Mean time to complete the instrument was five minutes. Feedback indicated that it was an acceptable and useful method of assessment. This new instrument provides valid, reliable, feasible, and acceptable assessment of clinical teaching.

  19. Validation of the U.S. NRC coupled code system TRITON/TRACE/PARCS with the special power excursion reactor test III (SPERT III)

    Energy Technology Data Exchange (ETDEWEB)

    Wang, R. C.; Xu, Y.; Downar, T. [Dept. of Nuclear Engineering and Radiological Sciences, Univ. of Michigan, Ann Arbor, MI 48104 (United States); Hudson, N. [RES Div., U.S. NRC, Rockville, MD (United States)

    2012-07-01

    The Special Power Excursion Reactor Test III (SPERT III) was a series of reactivity insertion experiments conducted in the 1950's. This paper describes the validation of the U.S. NRC Coupled Code system TRITON/PARCS/TRACE to simulate reactivity insertion accidents (RIA) by using several of the SPERT III tests. The work here used the SPERT III E-core configuration tests in which the RIA was initiated by ejecting a control rod. The resulting super-prompt reactivity excursion and negative reactivity feedback produced the familiar bell shaped power increase and decrease. The energy deposition during such a power peak has important safety consequences and provides validation basis for core coupled multi-physics codes. The transients of five separate tests are used to benchmark the PARCS/TRACE coupled code. The models were thoroughly validated using the original experiment documentation. (authors)

  20. [Comparison of the Wechsler Memory Scale-III and the Spain-Complutense Verbal Learning Test in acquired brain injury: construct validity and ecological validity].

    Science.gov (United States)

    Luna-Lario, P; Pena, J; Ojeda, N

    2017-04-16

    To perform an in-depth examination of the construct validity and the ecological validity of the Wechsler Memory Scale-III (WMS-III) and the Spain-Complutense Verbal Learning Test (TAVEC). The sample consists of 106 adults with acquired brain injury who were treated in the Area of Neuropsychology and Neuropsychiatry of the Complejo Hospitalario de Navarra and displayed memory deficit as the main sequela, measured by means of specific memory tests. The construct validity is determined by examining the tasks required in each test over the basic theoretical models, comparing the performance according to the parameters offered by the tests, contrasting the severity indices of each test and analysing their convergence. The external validity is explored through the correlation between the tests and by using regression models. According to the results obtained, both the WMS-III and the TAVEC have construct validity. The TAVEC is more sensitive and captures not only the deficits in mnemonic consolidation, but also in the executive functions involved in memory. The working memory index of the WMS-III is useful for predicting the return to work at two years after the acquired brain injury, but none of the instruments anticipates the disability and dependence at least six months after the injury. We reflect upon the construct validity of the tests and their insufficient capacity to predict functionality when the sequelae become chronic.

  1. Urease testing of mycobacteria with BACTEC radiometric instrumentation

    International Nuclear Information System (INIS)

    Damato, J.J.; Collins, M.T.; McClatchy, J.K.

    1982-01-01

    A total of 140 mycobacterial isolates from patients treated at Fitzsimons Army Medical Center or the National Jewish Hospital and Research Center and from animal specimens submitted to the National Veterinary Services Laboratory were tested by using a urease procedure modified for use with a BACTEC model 301. Mycobacterial suspensions were prepared by using Middlebrook 7H10 Tween broth. Of the 98 mycobacteria isolates which were urease positive utilizing standard methodology, all were positive using the radiometric procedures. Similarly, all 42 urease-negative isolates were also negative employing the new methodology. Although maximum radiometric readings were observed at 48 h, all positive strains were readily identified 24 h after inoculation without sacrificing either test sensitivity or specificity. Thus, urease testing of mycobacteria, using the modified BACTEC radiometric methodology, was as sensitive, as specific, and more rapid than conventional methods

  2. Plan for the testing of radiation measurement instrumentation intended for use at an excavation site

    International Nuclear Information System (INIS)

    Gehrke, R.J.

    1994-11-01

    This plan describes performance tests to be made with ionizing radiation measurement instrumentation designed and built for in-field assay at an excavation site. One instrument measures gross gamma-ray and neutron fields and the other identifies gamma-ray emitting radionuclides and also is capable of assaying for selected hazardous materials. These instruments will be operationally tested to verify that original specifications have been met and performance tested to establish and verify that they have the potential to function as intended at an excavation site

  3. Heat loss and fluid leakage tests of the ROSA-III facility

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Tasaka, Kanji; Shiba, Masayoshi

    1981-12-01

    The report presents characteristic test results about the steady state heat loss, one of the inherent characteristics of the ROSA-III test facility. The steady state heat loss tests were conducted at five different temperature conditions between 111 0 C and 290 0 C . Net heat loss rates were obtained by estimating the electric power supplied to the core, heat input from the recirculation pumps and steam leakage rate. The heat loss characteristics have important contribution to analyses of the ROSA-III small break tests. A following simple relation was obtained between the net heat loss rate Q*sub(HL) (kJ/s) (*: radical) of the ROSA-III facility and the temperature difference ΔT ( 0 C) between the fluid temperature of the system and the room temperature, Q*sub(HL) = 0.56 x ΔT. (*: radical) And the steam leak flow at normal operating condition of the ROSA-III test, (P = 7.2 MPa) was obtained as 8.9 x 10 -3 kg/s and corresponding steam leakage energy as 10.5 kJ/s. The heat input from the recirculation pumps was indirectly estimated under a constant speed by assuming the heat input was equal to the brake horce power of the pumps. (author)

  4. Neutron generator instrumentation at the Department 2350 Neutron Generator Test Facility

    International Nuclear Information System (INIS)

    Bryant, T.C.; Mowrer, G.R.

    1979-06-01

    The computer and waveform digitizing capability at the test facility has allowed several changes in the techniques used to test neutron generators. These changes include methods used to calibrate the instrumentation and changes in the operation of the test facility. These changes have increased the efficiency of the test facility as well as increasing both timing and amplitude accuracy of neutron generator waveforms

  5. Analysis of in-core coolant temperatures of FFTF instrumented fuels tests at full power

    International Nuclear Information System (INIS)

    Hoth, C.W.

    1981-01-01

    Two full size highly instrumented fuel assemblies were inserted into the core of the Fast Flux Test Facility in December of 1979. The major objectives of these instrumented tests are to provide verification of the FFTF core conditions and to characterize temperature patterns within FFTF driver fuel assemblies. A review is presented of the results obtained during the power ascents and during irradiation at a constant reactor power of 400 MWt. The results obtained from these instrumented tests verify the conservative nature of the design methods used to establish core conditions in FFTF. The success of these tests also demonstrates the ability to design, fabricate, install and irradiate complex, instrumented fuel tests in FFTF using commercially procured components

  6. A comparison of two reciprocating instruments using bending stress and cyclic fatigue tests

    Directory of Open Access Journals (Sweden)

    Pantaleo SCELZA

    2015-01-01

    Full Text Available The aim of this study was to comparatively evaluate the bending resistance at 45º, the static and dynamic cyclic fatigue life, and the fracture type of the WaveOne (Dentsply Maillefer, Ballaigues, Switzerland 25-08 and Reciproc (VDW, Munich, Germany 25-08 instruments. A total of 60 nickel-titanium (NiTi instruments (30 Reciproc and 30 WaveOne from three different lots, each of which was 25 mm in length, were tested. The bending resistance was evaluated through the results of a cantilever-bending test conducted using a universal testing machine. Static and dynamic cyclic fatigue testing was conducted using a custom-made device. For the static and dynamic tests, a cast Ni-Cr-Mo-Ti alloy metal block with an artificial canal measuring 1.77 mm in diameter and 20.00 mm in total length was used. A scanning electron microscope was used to determine the type of fracture. Statistical analyses were performed on the results. The WaveOne instrument was less flexible than the Reciproc (p < 0.05. The Reciproc instrument showed better resistance in the static and dynamic cyclic fatigue tests (p < 0.05. The transverse cross-section and geometry of the instruments were important factors in their resistance to bending and cyclic fracture. Both of the instruments showed ductile-type fracture characteristics. It can be concluded that the Reciproc 25-08 instrument was more resistant to static and dynamic cyclic fatigue than the WaveOne 25-08 instrument, while the WaveOne 25-08 instrument was less flexible. Bending and resistance to cyclic fracture were influenced by the instruments’ geometries and transverse cross-sections. Both of the instruments showed ductile-type fracture characteristics.

  7. The New Peabody Picture Vocabulary Test-III: An Illusion of Unbiased Assessment?

    Science.gov (United States)

    Stockman, Ida J

    2000-10-01

    This article examines whether changes in the ethnic minority composition of the standardization sample for the latest edition of the Peabody Picture Vocabulary Test (PPVT-III, Dunn & Dunn, 1997) can be used as the sole explanation for children's better test scores when compared to an earlier edition, the Peabody Picture Vocabulary Test-Revised (PPVT-R, Dunn & Dunn, 1981). Results from a comparative analysis of these two test editions suggest that other factors may explain improved performances. Among these factors are the number of words and age levels sampled, the types of words and pictures used, and characteristics of the standardization sample other than its ethnic minority composition. This analysis also raises questions regarding the usefulness of converting scores from one edition to the other and the type of criteria that could be used to evaluate whether the PPVT-III is an unbiased test of vocabulary for children from diverse cultural and linguistic backgrounds.

  8. The Hydraulic Test Report for Non-instrumented Irradiation Test Rig of DUO-Cooled Annular Pellet

    International Nuclear Information System (INIS)

    Kim, Dae Ho; Lee, Kang Hee; Shin, Chang Hwan; Yang, Yong Sik; Kim, Sun Ki; Bang, Je Geon; Song, Kun Woo

    2007-08-01

    This report presents the results of pressure drop test and vibration test for non-instrumented rig of Advanced PWR DUO-Fuel Annular Pellet which were designed and fabricated by KAERI. From the pressure drop test results, it is noted that the flow velocity across the non-instrumented rig of Advanced PWR DUO-Fuel Annular Pellet corresponding to the pressure drop of 200 kPa is measured to be about 8.30 kg/sec. Vibration frequency results for the non-instrumented rig at the pump spin frequency ranges from 19.0 to 32.0 Hz, RMS(Root Mean Square) displacement for the non-instrumented rig of Advanced PWR DUO-Fuel Annular Pellet is less than 7.25 m, and the maximum displacement is less than 31.27 μm. This test was performed at the FIVPET facility

  9. Evaluation of a draft standard on performance specifications for health physics instrumentation: results for environmental tests

    International Nuclear Information System (INIS)

    Kenoyer, J.L.; Swinth, K.L.; Mashburn, K.R.; Selby, J.M.

    1984-06-01

    Draft ANSI Standard N42.17 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. Evaluation is performed by testing a cross-section of currently available instruments with testing procedures based on specifications of the standard and then determining the degree of conformance to the various elements of the proposed standard. Data will be presented on the performance of a cross-section of beta-gamma survey instruments under various environmental tests. Test results that will be presented include temperature effects, humidity effects, radio frequency (r.f.) susceptibility, ambient pressure effects, vibration effects, and shock effects. Tests performed to date show that most instruments will meet the temperature, humidity, and ambient pressure tests. A large variability is noted among instruments from the same or different vendors. Preliminary r.f. susceptibility tests have shown large artificial responses at some frequencies for specific instruments. The presentation will also include a discussion of procedures used in the testing and weaknesses identified in the proposed standard

  10. Food-related life styles in Singapore: Testing a Western European research instrument in Southeast Asia

    DEFF Research Database (Denmark)

    Askegaard, Søren; Brunsø, Karen; Crippen, Kaye

    The food-related life style instrument developed by the MAPP research group has, up til now, been applied mainly in the context of European cultures. The purpose of the present study is to apply the food-related life style instrument in a new and very different cultural setting, to compare results......, and to interpret similarities and differences found. For this purpose, data have been collected in Singaporean families using the food-related life style instrument. A total of 89 questionnaires form the basis of the analysis. First, the cross-cultural validity of the instrument is tested, and secondly...

  11. Current Hypersonic and Space Vehicle Flight Test and Instrumentation

    Science.gov (United States)

    2015-06-22

    ground station hardware and software. B. Space- based Platforms There are already in place several satellite based options to collecting and... Transceive data over very long range at low to very high altitudes DARPA: XS-1 Ground Based Aircraft Based Space Based Future Data...412TW-PA-15264 AIR FORCE TEST CENTER EDWARDS AIR FORCE BASE , CALIFORNIA AIR FORCE MATERIEL COMMAND UNITED STATES AIR FORCE REPORT

  12. Development and testing of an assessment instrument for the formative peer review of significant event analyses.

    Science.gov (United States)

    McKay, J; Murphy, D J; Bowie, P; Schmuck, M-L; Lough, M; Eva, K W

    2007-04-01

    To establish the content validity and specific aspects of reliability for an assessment instrument designed to provide formative feedback to general practitioners (GPs) on the quality of their written analysis of a significant event. Content validity was quantified by application of a content validity index. Reliability testing involved a nested design, with 5 cells, each containing 4 assessors, rating 20 unique significant event analysis (SEA) reports (10 each from experienced GPs and GPs in training) using the assessment instrument. The variance attributable to each identified variable in the study was established by analysis of variance. Generalisability theory was then used to investigate the instrument's ability to discriminate among SEA reports. Content validity was demonstrated with at least 8 of 10 experts endorsing all 10 items of the assessment instrument. The overall G coefficient for the instrument was moderate to good (G>0.70), indicating that the instrument can provide consistent information on the standard achieved by the SEA report. There was moderate inter-rater reliability (G>0.60) when four raters were used to judge the quality of the SEA. This study provides the first steps towards validating an instrument that can provide educational feedback to GPs on their analysis of significant events. The key area identified to improve instrument reliability is variation among peer assessors in their assessment of SEA reports. Further validity and reliability testing should be carried out to provide GPs, their appraisers and contractual bodies with a validated feedback instrument on this aspect of the general practice quality agenda.

  13. Causal null hypotheses of sustained treatment strategies: What can be tested with an instrumental variable?

    Science.gov (United States)

    Swanson, Sonja A; Labrecque, Jeremy; Hernán, Miguel A

    2018-05-02

    Sometimes instrumental variable methods are used to test whether a causal effect is null rather than to estimate the magnitude of a causal effect. However, when instrumental variable methods are applied to time-varying exposures, as in many Mendelian randomization studies, it is unclear what causal null hypothesis is tested. Here, we consider different versions of causal null hypotheses for time-varying exposures, show that the instrumental variable conditions alone are insufficient to test some of them, and describe additional assumptions that can be made to test a wider range of causal null hypotheses, including both sharp and average causal null hypotheses. Implications for interpretation and reporting of instrumental variable results are discussed.

  14. Testing of Environmental Satellite Bus-Instrument Interfaces Using Engineering Models

    Science.gov (United States)

    Gagnier, Donald; Hayner, Rick; Nosek, Thomas; Roza, Michael; Hendershot, James E.; Razzaghi, Andrea I.

    2004-01-01

    This paper discusses the formulation and execution of a laboratory test of the electrical interfaces between multiple atmospheric scientific instruments and the spacecraft bus that carries them. The testing, performed in 2002, used engineering models of the instruments and the Aura spacecraft bus electronics. Aura is one of NASA s Earth Observatory System missions. The test was designed to evaluate the complex interfaces in the command and data handling subsystems prior to integration of the complete flight instruments on the spacecraft. A problem discovered during the flight integration phase of the observatory can cause significant cost and schedule impacts. The tests successfully revealed problems and led to their resolution before the full-up integration phase, saving significant cost and schedule. This approach could be beneficial for future environmental satellite programs involving the integration of multiple, complex scientific instruments onto a spacecraft bus.

  15. Vibration instrumentation of the tubes of the Paluel 1 steam generator no.4. Results of tests

    International Nuclear Information System (INIS)

    Gay, N.; Campistron, R.; Launay, J.

    1985-06-01

    This report gives an overview of the instrumentation and of the measuring unit. Then the different tests carried out as also their exploitation are presented. The results are presented in the lasp part [fr

  16. Void fraction instrument software, Version 1,2, Acceptance test report

    International Nuclear Information System (INIS)

    Gimera, M.

    1995-01-01

    This provides the report for the void fraction instrument acceptance test software Version 1.2. The void fraction will collect data that will be used to calculate the quantity of gas trapped in waste tanks

  17. The mechanical design and dynamic testing of the IBEX-H1 electrostatic analyzer spacecraft instrument

    Energy Technology Data Exchange (ETDEWEB)

    Bernardin, John D [Los Alamos National Laboratory; Baca, Allen G [SNL

    2009-01-01

    This paper presents the mechanical design, fabrication and dynamic testing of an electrostatic analyzer spacecraft instrument. The functional and environmental requirements combined with limited spacecraft accommodations, resulted in complex component geometries, unique material selections, and difficult fabrication processes. The challenging aspects of the mechanical design and several of the more difficult production processes are discussed. In addition, the successes, failures, and lessons learned from acoustic and random vibration testing of a full-scale prototype instrument are presented.

  18. High-speed instrumentation complex for car crash testing

    Science.gov (United States)

    Baranov, S. V.; Gorin, I. M.; Drozhbin, Yu. A.; Kuznetsov, A. A.; Ponomaryov, A. M.; Semyonov, V. B.; Udalov, V. V.

    1993-01-01

    One of the most important car checking problems consists in safety testing which includes trials for different types of collision, e.g., frontal and lateral. This allows us to study deformations of the automobile and its parts during the impact. To obtain reliable data on overloading, acceleration, deformation, force load on the car's body as well as on the anthropomorphic dummies inside it, use is made of rather a great number of different techniques. Highly informative among them is high-speed cine recording which allows us to register variations that occur during a fraction of a second, and then to reproduce with variable rate the frame images obtained. This makes it possible to study the impact parameters variations much more accurately.

  19. Cyclic fatigue resistance of ProTaper Universal instruments when subjected to static and dynamic tests.

    Science.gov (United States)

    Lopes, Hélio P; Britto, Izabelle M O; Elias, Carlos N; Machado de Oliveira, Julio C; Neves, Mônica A S; Moreira, Edson J L; Siqueira, José F

    2010-09-01

    This study evaluated the number of cycles to fracture of ProTaper Universal S2 instruments when subjected to static and dynamic cyclic fatigue tests. ProTaper Universal S2 instruments were used until fracture in an artificial curved canal under rotational speed of 300 rpm in either a static or a dynamic test model. Afterward, the length of the fractured segments was measured and fractured surfaces and helical shafts analyzed by scanning electron microscopy (SEM). The number of cycles to fracture was significantly increased when instruments were tested in the dynamic model (Pductile mode. Plastic deformation was not observed in the helical shaft of fractured instruments. The number of cycles to fracture ProTaper Universal S2 instruments significantly increased with the use of instruments in a dynamic cyclic fatigue test compared with a static model. These findings reinforce the need for performing continuous pecking motions during rotary instrumentation of curved root canals. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  20. Visual test and colorimetric determination of gold(III with the use of indicator paper

    Directory of Open Access Journals (Sweden)

    Svetlana N. Khudyakova

    2016-08-01

    Full Text Available A visual test method has been proposed for the evaluation of the gold content. It is based on the linear dependence between the length of the colored zone on an indicator paper and gold(III concentration. Indicator paper was covered by a polymer film and was in contact with the solution tested along one edge during analysis. It was impregnated by 3-phenyl-2,6-dimercapto-1,4-thiopyrone or by precipitate of its complex with copper(II. Besides Cu(II can be replaced by the Au(III ion tested in the composition of this complex. The concentration ranges for Au(III determination were equal to 0.02−2 mg·L−1 or 4−590 mg·L−1, respectively, in the presence of excess of the transition and noble metals. It was demonstrated the effectiveness of the dynamic preconcentration of Au(III for the subsequent colorimetric determination on paper filter for the concentration range 0.005–0.3 mg·L−1 (DL 0.02 mg·L−1 by using a sample volume of 10 mL. The developed procedures were successfully utilized for the determination of gold in synthetic mixtures, in auriferous quartz (RSD < 5%, and in ore from Zyryanovsk’s mine (Kazakhstan with RSD < 8%.

  1. Welding of sule elements for nuclear reactors with solid state YAG laser using instrumentated testing equipments

    International Nuclear Information System (INIS)

    Bourgault, F.; Lacoste, J.; Schley, R.; Kluzinski, C.; Piednoir, P.

    1985-09-01

    The instrumentation of the equipment for carrying out safety tests on fuel elements for nuclear reactors requires special thermocouples adapted to the prevailing agressive medium. The investigations described deal essentially with the operational and metallurgical weldability tests out on the safety test zircaloy piping in the pressurized water circuit (PHEBUS-programme) [fr

  2. 42 CFR 493.1252 - Standard: Test systems, equipment, instruments, reagents, materials, and supplies.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Test systems, equipment, instruments... SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY... storage of reagents and specimens, accurate and reliable test system operation, and test result reporting...

  3. Analysis of excess reactivity of JOYO MK-III performance test core

    International Nuclear Information System (INIS)

    Maeda, Shigetaka; Yokoyama, Kenji

    2003-10-01

    JOYO is currently being upgraded to the high performance irradiation bed JOYO MK-III core'. The MK-III core is divided into two fuel regions with different plutonium contents. To obtain a higher neutron flux, the active core height was reduced from 55 cm to 50 cm. The reflector subassemblies were replaced by shielding subassemblies in the outer two rows. Twenty of the MK-III outer core fuel subassemblies in the performance test core were partially burned in the transition core. Four irradiation test rigs, which do not contain any fuel material, were loaded in the center of the performance test core. In order to evaluate the excess reactivity of MK-III performance test core accurately, we evaluated it by applying not only the JOYO MK-II core management code system MAGI, but also the MK-III core management code system HESTIA, the JUPITER standard analysis method and the Monte Carlo method with JFS-3-J3.2R content set. The excess reactivity evaluations obtained by the JUPITER standard analysis method were corrected to results based on transport theory with zero mesh-size in space and angle. A bias factor based on the MK-II 35th core, which sensitivity was similar to MK-III performance test core's, was also applied, except in the case where an adjusted nuclear cross-section library was used. Exact three-dimensional, pin-by-pin geometry and continuous-energy cross sections were used in the Monte Carlo calculation. The estimated error components associated with cross-sections, methods correction factors and the bias factor were combined based on Takeda's theory. Those independently calculated values agree well and range from 2.8 to 3.4%Δk/kk'. The calculation result of the MK-III core management code system HESTLA was 3.13% Δk/kk'. The estimated errors for bias method range from 0.1 to 0.2%Δk/kk'. The error in the case using adjusted cross-section was 0.3%Δk/kk'. (author)

  4. Fabrication of the instrumented fuel rods for the 3-Pin Fuel Test Loop at HANARO

    International Nuclear Information System (INIS)

    Sohn, Jae Min; Park, Sung Jae; Shin, Yoon Tag; Lee, Jong Min; Ahn, Sung Ho; Kim, Soo Sung; Kim, Bong Goo; Kim, Young Ki; Lee, Ki Hong; Kim, Kwan Hyun

    2008-09-01

    The 3-Pin Fuel Test Loop(hereinafter referred to as the '3-Pin FTL') facility has been installed at HANARO(High-flux Advanced Neutron Application Reactor) and the 3-Pin FTL is under a test operation. The purpose of this report is to fabricate the instrumented fuel rods for the 3-Pin FTL. The fabrication of these fuel rods was based on experiences and technologies of the instrumented fuel rods for an irradiation fuel capsule. The three instrumented fuel rods of the 3-Pin FTL have been designed. The one fuel rod(180 .deg. ) was designed to measure the centerline temperature of the nuclear fuels and the internal pressure of the fuel rod, and others(60 .deg. and 300 .deg. ) were designed to measure the centerline temperature of the fuel pellets. The claddings were made of the reference material 1 and 2 and new material 1 and 2. And nuclear fuel was used UO 2 (2.0w/o) pellet type with large grain and standard grain. The major procedures of fabrication are followings: (1) the assembling and weld of fuel rods with the pellet mockups and the sensor mockups for the qualification tests, (2) the qualification tests(dimension measurements, tensile tests, metallography examinations and helium leak tests) of weld, (3) the assembling and weld of instrumented fuel rods with the nuclear pellets and the sensors for the irradiation test, and (4) the qualification tests(the helium leak test, the dimensional measurement, electric resistance measurements of sensors) of test fuel rods. Satisfactory results were obtained for all the qualification tests of the instrumented fuel rods for the 3-Pin FTL. Therefore the three instrumented fuel rods for the 3-Pin FTL have been fabricated successfully. These will be installed in the In-Pile Section of 3-Pin FTL. And the irradiation test of these fuel rods is planned from the early next year for about 3 years at HANARO

  5. In-Pile Testing and Instrumentation for Development of Generation-IV Fuels and Materials. Proceedings of a Technical Meeting

    International Nuclear Information System (INIS)

    2013-12-01

    specialists from 19 countries. The twenty papers presented were organized into three sessions covering the areas of instrumentation development, irradiation techniques and the description of some experimental studies. Although most papers focused on advanced techniques applied to aid the understanding of high burnup Generation III/III+ fuel behaviour, several presentations were devoted to the specific testing techniques applicable for new fuel and structural materials considered for Generation-IV systems. It was noted that research instrumentation for Generation-IV reactors requires devices capable of surviving in very high temperature and corrosive environments with very high neutron doses. Such developments are extremely challenging and are currently at a conceptual stage

  6. ROSA-III 200% double-ended break integral test RUN 901

    International Nuclear Information System (INIS)

    Nakamura, Hideo; Tasaka, Kanji; Koizumi, Yasuo; Anoda, Yoshinari; Kumamaru, Hiroshige; Murata, Hideo; Suzuki, Mitsuhiro; Shiba, Masayoshi

    1984-02-01

    This report presents the experimental data of RUN 901, a 200% double-ended break test at the recirculation pump suction line with the ROSA-III test facility. The ROSA-III test facility is a volumetrically scaled (1/424) system of the BWR/6. The facility has the electrically heated core, the break simulator and the scaled ECCS (Emergency Core Cooling System). The MSIV closure and the ECCS actuation were tripped by the liquid level in the upper downcomer. The channel inlet flows were measured by differential pressure transducers installed at the channel inlet orifices of the fuel assembly No.4. The PCT (Peak Cladding Temperature) was 780 K occured during the blowdown phase in RUN 901. The whole core was quenched after the ECCS actuation and the effectiveness of ECCS has been confirmed. (author)

  7. A Method for Modeling the Virtual Instrument Automatic Test System Based on the Petri Net

    Institute of Scientific and Technical Information of China (English)

    MA Min; CHEN Guang-ju

    2005-01-01

    Virtual instrument is playing the important role in automatic test system. This paper introduces a composition of a virtual instrument automatic test system and takes the VXIbus based a test software platform which is developed by CAT lab of the UESTC as an example. Then a method to model this system based on Petri net is proposed. Through this method, we can analyze the test task scheduling to prevent the deadlock or resources conflict. At last, this paper analyzes the feasibility of this method.

  8. A comparison of two reciprocating instruments using bending stress and cyclic fatigue tests.

    Science.gov (United States)

    Scelza, Pantaleo; Harry, Davidowicz; Silva, Licinio Esmeraldo da; Barbosa, Igor Bastos; Scelza, Miriam Zaccaro

    2015-01-01

    The aim of this study was to comparatively evaluate the bending resistance at 45º, the static and dynamic cyclic fatigue life, and the fracture type of the WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) 25-08 and Reciproc (VDW, Munich, Germany) 25-08 instruments. A total of 60 nickel-titanium (NiTi) instruments (30 Reciproc and 30 WaveOne) from three different lots, each of which was 25 mm in length, were tested. The bending resistance was evaluated through the results of a cantilever-bending test conducted using a universal testing machine. Static and dynamic cyclic fatigue testing was conducted using a custom-made device. For the static and dynamic tests, a cast Ni-Cr-Mo-Ti alloy metal block with an artificial canal measuring 1.77 mm in diameter and 20.00 mm in total length was used. A scanning electron microscope was used to determine the type of fracture. Statistical analyses were performed on the results. The WaveOne instrument was less flexible than the Reciproc (p fatigue tests (p ductile-type fracture characteristics. It can be concluded that the Reciproc 25-08 instrument was more resistant to static and dynamic cyclic fatigue than the WaveOne 25-08 instrument, while the WaveOne 25-08 instrument was less flexible. Bending and resistance to cyclic fracture were influenced by the instruments' geometries and transverse cross-sections. Both of the instruments showed ductile-type fracture characteristics.

  9. Evaluation of candidate magnetohydrodynamic materials for the U-02 Phase III test

    International Nuclear Information System (INIS)

    Marchant, D.D.; Bates, J.L.

    1978-06-01

    As part of a cooperative U.S.--U.S.S.R. program, electrode and insulator materials tested at the Westinghouse Electrode Systems Test Facility in Pittsburgh, Pennsylvania, were evaluated. From this evaluation materials will be selected for use in the third phase of tests being conducted in the U-02 magnetohydrodynamics test facility in the Soviet Union. Electrode and insulator materials were examined with both an optical microscope and a scanning electron microscope. The cathodes were found to behave differently from the anodes; most notably, the cathodes showed greater potassium interaction. The lanthanum chromite-based electrodes (excluding those fabricated by plasma-spraying) are recommended for testing in the U-02 Phase III test. Hotpressed, fused-grained MgO and sintered MgAl 2 O 4 are recommended as insulator materials. The electrode attachment techniques used in the Westinghouse Tests were inadequate and need to be modified for the U-02 test

  10. The Thermal-hydraulic Performance Test Report for the Non-instrumented Irradiation Test Rig of Annular Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Lee, Kang Hee; Shin, Chang Hwan

    2008-09-15

    This report presents the results of pressure drop test, vibration test and endurance test for the non-instrumented rig using the irradiation test in HANARO of the double cooled annular fuel which were designed and fabricated by KAERI. From the out-pile thermal hydraulic tests, corresponding to the pressure drop of 200 kPa is measured to be about 9.72 kg/sec. Vibration frequency for the non-instrumented rig ranges from 5.0 to 10.7 kg/s. RMS(Root Mean Square) displacement for non-instrumented rig is less than 11.73 m, and the maximum displacement is less than 54.87m. The flow rate for endurance test were 10.5 kg/s, which was 110% of 9.72 kg/s. And the endurance test was carried out for 3 days. The test results found not to the wear and satisfied to the limits of pressure drop, flow rate, vibration and wear in the non-instrumented rig. This test was performed at the FIVPET facility.

  11. Robust electrochemical analysis of As(III) integrating with interference tests: A case study in groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Zhong-Gang [Nanomaterials and Environmental Detection Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031 (China); Department of Chemistry, University of Science and Technology of China, Hefei 230026 (China); Chen, Xing; Liu, Jin-Huai [Nanomaterials and Environmental Detection Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031 (China); Huang, Xing-Jiu, E-mail: xingjiuhuang@iim.ac.cn [Nanomaterials and Environmental Detection Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031 (China); Department of Chemistry, University of Science and Technology of China, Hefei 230026 (China)

    2014-08-15

    Graphical abstract: - Highlights: • Robust determination of As(III) in Togtoh water samples has been demonstrated. • The results were comparable to that obtained by ICP–AES. • No obvious interference was observed after a series of interference tests. • Robust stability was obtained in long-term measurements. - Abstract: In Togtoh region of Inner Mongolia, northern China, groundwater encountered high concentrations As contamination (greater than 50 μg L{sup −1}) causes an increasing concern. This work demonstrates an electrochemical protocol for robust (efficient and accurate) determination of As(III) in Togtoh water samples using Au microwire electrode without the need of pretreatment or clean-up steps. Considering the complicated conditions of Togtoh water, the efficiency of Au microwire electrode was systematically evaluated by a series of interference tests, stability and reproducibility measurements. No obvious interference on the determination of As(III) was observed. Especially, the influence of humic acid (HA) was intensively investigated. Electrode stability was also observed with long-term measurements (70 days) in Togtoh water solution and under different temperatures (0–35 °C). Excellent reproducibility (RSD:1.28%) was observed from different batches of Au microwire electrodes. The results obtained at Au microwire electrode were comparable to that obtained by inductively coupled plasma atomic emission spectroscopy (ICP–AES), indicating a good accuracy. These evaluations (efficiency, robustness, and accuracy) demonstrated that the Au microwire electrode was able to determine As(III) in application to real environmental samples.

  12. Quality assessment in in vivo NMR spectroscopy: III. Clinical test objects: design, construction, and solutions

    DEFF Research Database (Denmark)

    Leach, M.O.; Collins, D.J.; Keevil, S

    1995-01-01

    /Perspex interface produced minimum susceptibility effects. The design of the objects has been evaluated in trials on different magnetic resonance instruments, with size and loading being adjusted to allow use on currently available equipment. Appropriate test solutions for 31P and 1H measurements have been...

  13. Test - retest reliability of two instruments for measuring public attitudes towards persons with mental illness

    Directory of Open Access Journals (Sweden)

    Leufstadius Christel

    2011-01-01

    Full Text Available Abstract Background Research has identified stigmatization as a major threat to successful treatment of individuals with mental illness. As a consequence several anti-stigma campaigns have been carried out. The results have been discouraging and the field suffers from lack of evidence about interventions that work. There are few reports on psychometric data for instruments used to assess stigma, which thus complicates research efforts. The aim of the present study was to investigate test-retest reliability of the Swedish versions of the questionnaires: FABI and "Changing Minds" and to examine the internal consistency of the two instruments. Method Two instruments, fear and behavioural intentions (FABI and "Changing Minds", used in earlier studies on public attitudes towards persons with mental illness were translated into Swedish and completed by 51 nursing students on two occasions, with an interval of three weeks. Test-retest reliability was calculated by using weighted kappa coefficient and internal consistency using the Cronbach's alpha coefficient. Results Both instruments attain at best moderate test-retest reliability. For the Changing Minds questionnaire almost one fifth (17.9% of the items present poor test-retest reliability and the alpha coefficient for the subscales ranges between 0.19 - 0.46. All of the items in the FABI reach a fair or a moderate agreement between the test and retest, and the questionnaire displays a high internal consistency, alpha 0.80. Conclusions There is a need for development of psychometrically tested instruments within this field of research.

  14. The test beamline of the European Spallation Source - Instrumentation development and wavelength frame multiplication

    DEFF Research Database (Denmark)

    Woracek, R.; Hofmann, T.; Bulat, M.

    2016-01-01

    which, in contrast, are all providing short neutron pulses. In order to enable the development of methods and technology adapted to this novel type of source well in advance of the first instruments being constructed at ESS, a test beamline (TBL) was designed and built at the BER II research reactor...... wavelength band between 1.6 A and 10 A by a dedicated wavelength frame multiplication (WFM) chopper system. WFM is proposed for several ESS instruments to allow for flexible time-of-flight resolution. Hence, ESS will benefit from the TBL which offers unique possibilities for testing methods and components....... This article describes the main capabilities of the instrument, its performance as experimentally verified during the commissioning, and its relevance to currently starting ESS instrumentation projects....

  15. Reactor building pressure proof test (PPT) and leak rate test (LRT) of Qinshan phase III (CANDU) project

    International Nuclear Information System (INIS)

    Gu Jun; Shi Jinqi; Fan Fuping

    2004-12-01

    As the first reactor building (R/B) without stainless steel liner in china, TQNPC studied the containment characteristics, such as strong concrete absorb/release air effect, poor containment penetration. etc. And carefully prepared test scheme and emergency response, creatively introduced the instrument air self-supply system in reactor building, developed the special measurement and analysis system for PPT and LRT, organized work under high-pressure on large-scale in the test. Finally got the containment leak rate result and the test-cost-time value is the best in all same type tests. (authors)

  16. Electronic constant current and current pulse signal generator for nuclear instrumentation testing

    International Nuclear Information System (INIS)

    Brown, R.A.

    1994-01-01

    Circuitry is described for testing the ability of an intermediate range nuclear instrument to detect and measure a constant current and a periodic current pulse. The invention simulates the resistance and capacitance of the signal connection of a nuclear instrument ion chamber detector and interconnecting cable. An LED flasher/oscillator illuminates an LED at a periodic rate established by a timing capacitor and circuitry internal to the flasher/oscillator. When the LED is on, a periodic current pulse is applied to the instrument. When the LED is off, a constant current is applied. An inductor opposes battery current flow when the LED is on. 1 figures

  17. Data report on spray cooling test by ROSA-III, (1)

    International Nuclear Information System (INIS)

    Sobajima, Makoto; Murata, Hideo; Shiba, Masayoshi

    1980-03-01

    A separate effect test on spray cooling was carried out using one core channel of ROSA-III BWR LOCA test facility. This report describes a heating experiment in the series of runs. (1) The cooling from top of the core by spray easily causes countercurrent flow limit due to the vaparization of falling water itself, so it becomes in effective. (2) The cooling by falling water is irregular and unstable. Therefore, the cooling by the falling water is not to be relied on. (3) CCFL at porous plate is hard to occur, compared with single pipe. A quantitative study of this is desired to evaluate reflooding rate. Some suggestions for ROSA-III design are also made. (author)

  18. Mechanical, electronic and instrumentation development for tracer tests at El Berrocal site

    International Nuclear Information System (INIS)

    Gutierrez, M.G.; Benitez, A.H.; Yllera de Llano, A.; Romero, P.R.; Aleixandre, J.; Bueno, J.; Gonzalez, O.; Tamarit, J.; Guimera, J.

    1997-01-01

    The international El Berrocal Project was an integrated exercise in geological, geochemical and hydrogeological characterization with the aim of understanding and modelling the past and present-day migration processes that control the behaviour and distribution of naturally occurring radionuclides in a fractured granitic environment. Information is presented concerning the design and manufacture of the instrumentation used for the large scale tracer tests performed at El Berrocal, and the instrumentation and data acquisition development is specified. (author)

  19. The collection and analysis of transient test data using the mobile instrumentation data acquisition system (MIDAS)

    International Nuclear Information System (INIS)

    Uncapher, W.L.; Arviso, M.

    1995-01-01

    Packages designed to transport radioactive materials are required to survive exposure to environments defined in Code of Federal Regulations. Cask designers can investigate package designs through structural and thermal testing of full-scale packages, components, or representative models. The acquisition of reliable response data from instrumentation measurement devices is an essential part of this testing activity. Sandia National Laboratories, under the sponsorship of the US Department of Energy (DOE), has developed the Mobile Instrumentation Data Acquisition System (MIDAS) dedicated to the collection and processing of structural and thermal data from regulatory tests

  20. Eddy current testing instruments manufactured by the production unit of the Brno Technical University

    International Nuclear Information System (INIS)

    Fiala, I.

    1989-01-01

    Three materials testing machines are described. The ECTER general-purpose machine for materials testing in diagnostics of selected components of nuclear power plants can be used in detection and monitoring of defects of non-ferromagnetic tubes in heat exchangers using an immersion probe for crack, wall thickness and corrosion detection. The instrument for inspection of pipe welding joints, DEST-1, is the sensor of the control system of a welder for axially welded pipes. The third instrument, a device for detection of surface defects in metallic materials is used for testing steel rod materials. It is used in screw mills. (M.D.). 2 figs

  1. Cryo-Vacuum Testing of the Integrated Science Instrument Module for the James Webb Space Telescope

    Science.gov (United States)

    Kimble, Randy A.; Davila, P. S.; Drury, M. P.; Glazer, S. D.; Krom, J. R.; Lundquist, R. A.; Mann, S. D.; McGuffey, D. B.; Perry, R. L.; Ramey, D. D.

    2011-01-01

    With delivery of the science instruments for the James Webb Space Telescope (JWST) to Goddard Space Flight Center (GSFC) expected in 2012, current plans call for the first cryo-vacuum test of the Integrated Science Instrument Module (ISIM) to be carried out at GSFC in early 2013. Plans are well underway for conducting this ambitious test, which will perform critical verifications of a number of optical, thermal, and operational requirements of the IS 1M hardware, at its deep cryogenic operating temperature. We describe here the facilities, goals, methods, and timeline for this important Integration & Test milestone in the JWST program.

  2. Instruments for non-destructive evaluation of advanced test reactor inpile tubes

    International Nuclear Information System (INIS)

    Livingston, R.A.; Beller, L.S.; Edgett, S.M.

    1986-01-01

    The Advanced Test Reactor is a 250 MW LWR used primarily for irradiation testing of materials contained in inpile tubes that pass through the reactor core. These tubes provided the high pressure and temperature water environment required for the test specimens. The reactor cooling water surrounding the inpile tubes is at much lower pressure and temperature. The structural integrity of the inpile tubes is monitored by routine surveillance to ensure against unplanned reactor shutdowns to replace defective inpile tubes. The improved instruments developed for inpile tube surveillance include a bore profilometer, ultrasonic flaw detetion system and bore diameter gauges. The design and function of these improved instruments is presented

  3. Cryo Testing of tbe James Webb Space Telescope's Integrated Science Instrument Module

    Science.gov (United States)

    VanCampen, Julie

    2004-01-01

    The Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope will be integrated and tested at the Environmental Test Facilities at Goddard Space Flight Center (GSFC). The cryogenic thermal vacuum testing of the ISIM will be the most difficult and problematic portion of the GSFC Integration and Test flow. The test is to validate the coupled interface of the science instruments and the ISIM structure and to sufficiently stress that interface while validating image quality of the science instruments. The instruments and the structure are not made from the same materials and have different CTE. Test objectives and verification rationale are currently being evaluated in Phase B of the project plan. The test program will encounter engineering challenges and limitations, which are derived by cost and technology many of which can be mitigated by facility upgrades, creative GSE, and thorough forethought. The cryogenic testing of the ISIM will involve a number of risks such as the implementation of unique metrology techniques, mechanical, electrical and optical simulators housed within the cryogenic vacuum environment. These potential risks are investigated and possible solutions are proposed.

  4. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''P''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping Instrumentation and Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis

  5. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid Q

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping Instrumentation and Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis

  6. Acceptance Test Procedure for New Pumping and Instrumentation Control Skid M

    International Nuclear Information System (INIS)

    KOCH, M.R.

    1999-01-01

    This Acceptance Test Procedure (ATP) verifies proper construction per the design drawings and tests for proper functioning of the Pumping and Instrumentation Control (PIC) skid ''M''. The Scope section lists the systems and functions to be checked. This ATP will be performed at the Site Fabrication Service's (SFS) shop upon completion of construction of the PIC skid

  7. Acceptance Test Procedure for New Pumping Instrumentation and Control Skid ''V''

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This Acceptance Test Procedure (ATP) verifies proper construction per the design drawings and tests for proper functioning of the Pumping Instrumentation and Control (PIC) skid ''V''. The scope section lists the systems and functions to be checked. This ATP will be performed at the Site Fabrication Services (SFS) shop upon completion of the construction of the PIC skid

  8. Design verification test of instrumented capsule (02F-11K) for nuclear fuel irradiation in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Sohn, J. M.; Oh, J. M. [and others

    2004-01-01

    An instrumented capsule is being developed to be able to measure fuel characteristics, such as fuel temperature, internal pressure of fuel rod, fuel elongation, and neutron flux, etc., during the irradiation test of nuclear fuel in HANARO. The instrumented capsule for measuring and monitoring fuel centerline temperature and neutron flux was designed and manufactured. The instrumented capsule includes three test fuel rods installed thermocouple to measure fuel centerline temperature and three SPNDs (Self-Powered Neutron Detector) to monitor the neutron flux. Its stability was verified by out-of-pile performance test, and its safety evaluation was also shown that the safety requirements were satisfied. And then, to verify the design of the instrumented capsule in the test hole, it was successfully irradiated in the test hole of HANARO from March 14, 2003 to June 1, 2003 (53.8 full power days at 24 MWth). During irradiation, the centerline temperature of PWR UO{sub 2} fuel pellets fabricated by KEPCO Nuclear Fuel Company and the neutron flux were continuously measured and monitored. The test fuel rods were irradiated at less than 350 W/cm to 5.13 GWD/MTU with fuel centerline peak temperature below 1,375 .deg. C. The structural stability of the capsule was satisfied by the naked eye in service pool of HANARO. The capsule and test fuel rods were dismantled and test fuel rods were examined at the hot cell of IMEF (Irradiated Material Examination Facility)

  9. Explaining perceived oral texture of starch-based custard desserts from standard and novel instrumental tests

    NARCIS (Netherlands)

    Wijk, R.A.de; Prinz, J.F.; Janssen, A.M.

    2006-01-01

    A number of in vitro and in vivo instrumental tests have been developed to reflect various aspects of the perceived oral texture of starch-based vanilla custard desserts. These tests include measurements of the food's infra-red reflectance (IRR), of the turbidity of spat-out rinse water, and of the

  10. Multi-site testing and evaluation of remote sensing instruments for wind energy applications

    DEFF Research Database (Denmark)

    Sanz Rodrigo, J.; Borbon Guillen, F.; Gomez Arranz, P.

    2013-01-01

    A procedure for testing and evaluation of remote sensing instruments that makes use of two test sites in flat and complex terrain is presented. To illustrate the method, a system intercomparison experiment is presented involving one sodar and two lidars (pulsed and continuous-wave). The wind...

  11. A new device to test cutting efficiency of mechanical endodontic instruments

    Science.gov (United States)

    Rubini, Alessio Giansiracusa; Plotino, Gianluca; Al-Sudani, Dina; Grande, Nicola M.; Putorti, Ermanno; Sonnino, GianPaolo; Cotti, Elisabetta; Testarelli, Luca; Gambarini, Gianluca

    2014-01-01

    Background The purpose of the present study was to introduce a new device specifically designed to evaluate the cutting efficiency of mechanically driven endodontic instruments. Material/Methods Twenty new Reciproc R25 (VDW, Munich, Germany) files were used to be investigated in the new device developed to test the cutting ability of endodontic instruments. The device consists of a main frame to which a mobile plastic support for the hand-piece is connected and a stainless-steel block containing a Plexiglas block against which the cutting efficiency of the instruments was tested. The length of the block cut in 1 minute was measured in a computerized program with a precision of 0.1mm. The instruments were activated by using a torque-controlled motor (Silver Reciproc; VDW, Munich, Germany) in a reciprocating movement by the “Reciproc ALL” program (Group 1) and in counter-clockwise rotation at 300 rpm (Group 2). Mean and standard deviations of each group were calculated and data were statistically analyzed with a one-way ANOVA test (P0.05). Conclusions The cutting testing device evaluated in the present study was reliable and easy to use and may be effectively used to test cutting efficiency of both rotary and reciprocating mechanical endodontic instruments. PMID:24603777

  12. Under sodium reliability tests on core components and in-core instrumentation

    International Nuclear Information System (INIS)

    Ruppert, E.; Stehle, H.; Vinzens, K.

    1977-01-01

    A sodium test facility for fast breeder core components (AKB), built by INTERATOM at Bensberg, has been operating since 1971 to test fuel dummies and blanket elements as well as absorber elements under simulated normal and extreme reactor conditions. Individual full-scale fuel or blanket elements and arrays of seven elements, modelling a section of the SNR-300 reactor core, have been tested under a wide range of sodium mass flow and isothermal test conditions up to 925K as well as under cyclic changed temperature transients. Besides endurance testing of the core components a special sodium and high-temperature instrumentation is provided to investigate thermohydraulic and vibrational behaviour of the test objects. During all test periods the main subassembly characteristics could be reproduced and the reliability of the instrumentation could be proven. (orig.) [de

  13. Development of a facility using robotics for testing automation of inertial instruments

    Science.gov (United States)

    Greig, Joy Y.; Lamont, Gary B.; Biezad, Daniel J.; Lewantowicz, Zdsislaw H.; Greig, Joy Y.

    1987-01-01

    The Integrated Robotics System Simulation (ROBSIM) was used to evaluate the performance of the PUMA 560 arm as applied to testing of inertial sensors. Results of this effort were used in the design and development of a feasibility test environment using a PUMA 560 arm. The implemented facility demonstrated the ability to perform conventional static inertial instrument tests (rotation and tumble). The facility included an efficient data acquisitions capability along with a precision test servomechanism function resulting in various data presentations which are included in the paper. Analysis of inertial instrument testing accuracy, repeatability and noise characteristics are provided for the PUMA 560 as well as for other possible commercial arm configurations. Another integral aspect of the effort was an in-depth economic analysis and comparison of robot arm testing versus use of contemporary precision test equipment.

  14. Out-pile test of non-instrumented capsule for the advanced PWR fuel pellets in HANARO irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. H.; Lee, C. B.; Oh, D. S.; Bang, J. K.; Kim, Y. M.; Yang, Y. S.; Jeong, Y. H.; Jeon, H. K.; Ryu, J. S. [KAERI, Taejon (Korea, Republic of)

    2002-05-01

    Non-instrumental capsule were designed and fabricated to irradiate the advanced pellet developed for the high burn-up LWR fuel in the HANARO in-pile capsule. This capsule was out-pie tested at Cold Test Loop-I in KAERI. From the pressure drop test results, it is noted that the flow velocity across the non-instrumented capsule of advanced PWR fuel pellet corresponding to the pressure drop of 200 kPa is measured to be about 7.45 kg/sec. Vibration frequency for the capsule ranges from 13.0 to 32.3 Hz. RMS displacement for non-instrumented capsule of advanced PWR fuel pellet is less than 11.6 {mu}m, and the maximum displacement is less that 30.5 {mu}m. The flow rate for endurance test were 8.19 kg/s, which was 110% of 7.45 kg/s. And the endurance test was carried out for 100 days and 17 hours. The test results found not to the wear satisfied to the limits of pressure drop, flow rate, vibration and wear in the non-instrumented capsule.

  15. Instrumentation Technologies for Improving an Irradiation Testing of Nuclear Fuels and Materials at the HANARO

    International Nuclear Information System (INIS)

    Kim, Bong Goo; Park, Sung Jae; Choo, Ki Nam

    2011-01-01

    Over 50 years of nuclear fuels and materials irradiation testing has led to many countries developing significant improvements in instrumentation to monitor physical parameters and to control the test conditions in Materials Test Reactors (MTRs) or research reactors. Recent effort to deploy new fuels and materials in existing and advanced reactors has increased the demand for well-instrumented irradiation tests. Specifically, demand has increased for tests with sensors capable of providing real-time measurement of key parameters, such as temperature, geometry changes, thermal conductivity, fission gas release, cracking, coating buildup, thermal and fast flux, etc. This review paper documents the current state of instrumentation technologies in MTRs in the world and summarizes on-going research efforts to deploy new sensors. There is increased interest to irradiate new materials and reactor fuels for advanced PWRs and the Gen-IV reactor systems, such as SFRs (Sodium-cooled Fast Reactors), VHTRs (Very-High-Temperature Reactors), SCWRs (Supercritical-Water-cooled Reactors) and GFRs (Gas-cooled Fast Reactor). This review documents the current state of instrumentation technologies in MTRs in the world, identifies challenges faced by previous testing methods and how these challenges were overcome. A wide range of sensors are available to measure key parameters of interest during fuels and materials irradiations in MTRs. Such sensors must be reliable, small size, highly accurate, and able to withstand harsh conditions. On-going development efforts are focusing on providing MTR users a wider range of parameter measurements with increased accuracy. In addition, development efforts are focusing on reducing the impact of sensor on measurements by reducing sensor size. This report includes not only status of instrumentation using research reactors in the world to irradiate nuclear fuels and materials but also future directions relating to instrumentation technologies for

  16. Measurement techniques and instruments suitable for life-prediction testing of photovoltaic arrays. Interim report

    Energy Technology Data Exchange (ETDEWEB)

    Noel, G.T.; Sliemers, F.A.; Deringer, G.C.; Wood, V.E.; Wilkes, K.E.; Gaines, G.B.; Carmichael, D.C.

    1978-01-15

    The validation of a service life of 20 years for low-cost photovoltaic arrays must be accomplished through accelerated life-prediction tests. A methodology for such tests has been developed in a preceding study. The results discussed consist of the initial identification and assessment of all known measurement techniques and instruments that might be used in these life-prediction tests. Array failure modes, relevant materials property changes, and primary degradation mechanisms are discussed as a prerequisite to identifying suitable measurement techniques and instruments. Candidate techniques and instruments are identified on the basis of extensive reviews of published and unpublished information. These methods are organized in six measurement categories--chemical, electrical, optical, thermal, mechanical, and ''other physicals''. Using specified evaluation criteria, the most promising techniques and instruments for use in life-prediction tests of arrays are then selected. These recommended techniques and their characteristics are described. Recommendations are made regarding establishment of the adequacy, particularly with respect to precision, of the more fully developed techniques for this application, and regarding the experimental evaluation of promising developmental techniques. Measurement needs not satisfied by presently available techniques/instruments are also identified.

  17. Performing T-tests to Compare Autocorrelated Time Series Data Collected from Direct-Reading Instruments.

    Science.gov (United States)

    O'Shaughnessy, Patrick; Cavanaugh, Joseph E

    2015-01-01

    Industrial hygienists now commonly use direct-reading instruments to evaluate hazards in the workplace. The stored values over time from these instruments constitute a time series of measurements that are often autocorrelated. Given the need to statistically compare two occupational scenarios using values from a direct-reading instrument, a t-test must consider measurement autocorrelation or the resulting test will have a largely inflated type-1 error probability (false rejection of the null hypothesis). A method is described for both the one-sample and two-sample cases which properly adjusts for autocorrelation. This method involves the computation of an "equivalent sample size" that effectively decreases the actual sample size when determining the standard error of the mean for the time series. An example is provided for the one-sample case, and an example is given where a two-sample t-test is conducted for two autocorrelated time series comprised of lognormally distributed measurements.

  18. The Influence of Instrumented Striker Configuration on the Results of Dynamic Toughness Testing

    International Nuclear Information System (INIS)

    Lucon, E.

    2008-01-01

    Several studies are available on the influence of the edge radius of instrumented strikers (ASTM - 8 mm or ISO - 2 mm) on the results of both non instrumented and instrumented Charpy tests. This paper investigates the effect of using either a 2 mm or a 8 mm striker when performing dynamic toughness tests at impact loading rates on precracked Charpy specimens. Existing data from tests run in the ductile-to-brittle region (dynamic Master Curve reference temperature) and in the upper shelf regime (ductile initiation fracture toughness and crack resistance curves) have been analyzed. The results show that 2 mm strikers tend to yield lower cleavage fracture toughness in the transition region (although the effect cannot be considered statistically significant), whereas the influence of striker configuration is negligible in the upper shelf regime when data are generated using the low-blow multiple-specimen technique.

  19. The Influence of Instrumented Striker Configuration on the Results of Dynamic Toughness Testing

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.

    2008-09-15

    Several studies are available on the influence of the edge radius of instrumented strikers (ASTM - 8 mm or ISO - 2 mm) on the results of both non instrumented and instrumented Charpy tests. This paper investigates the effect of using either a 2 mm or a 8 mm striker when performing dynamic toughness tests at impact loading rates on precracked Charpy specimens. Existing data from tests run in the ductile-to-brittle region (dynamic Master Curve reference temperature) and in the upper shelf regime (ductile initiation fracture toughness and crack resistance curves) have been analyzed. The results show that 2 mm strikers tend to yield lower cleavage fracture toughness in the transition region (although the effect cannot be considered statistically significant), whereas the influence of striker configuration is negligible in the upper shelf regime when data are generated using the low-blow multiple-specimen technique.

  20. Hybrid III anthropomorphic test device (ATD) response to head impacts and potential implications for athletic headgear testing.

    Science.gov (United States)

    Bartsch, Adam; Benzel, Edward; Miele, Vincent; Morr, Douglas; Prakash, Vikas

    2012-09-01

    The Hybrid III 50th percentile male anthropomorphic test device (ATD) is the most widely used human impact testing surrogate and has historically been used in automotive or military testing. More recently, this ATD is finding use in applications evaluating athletic helmet protectivity, quantifying head impact dosage and estimating injury risk. But ATD head-neck response has not been quantified in omnidirectional athletic-type head impacts absent axial preload. It is probable that headgear injury reduction that can be quantified in a laboratory, including in American football, boxing, hockey, lacrosse and soccer, is related to a number of interrelated kinetic and kinematic factors, such as head center of gravity linear acceleration, head angular acceleration, head angular velocity, occipito-cervical mechanics and neck stiffness. Therefore, we characterized ATD head-neck dynamic response to direct head impacts in a series of front, oblique front and lateral head impacts. Key findings were: (1) impacts producing highest ATD resultant center of gravity linear acceleration resulted in the lowest resultant occipito-cervical spine bending moment/force. (2) Resultant ATD head angular velocity and angular acceleration did not appear coupled to impact direction at lower impact energy levels; these parameters were coupled at higher energy levels. (3) The ATD had progressively increasing occipito-cervical stiffness in extension, torsion and lateral bending, respectively. Because the ATD neck influenced head and neck impact dosage parameters, testing agencies, manufacturers and researchers should consider using the Hybrid III head form attached to a neck as a means to quantify head and neck injury risks as opposed to systems that do not utilize a neck. This heightened understanding of Hybrid III ATD head-neck response, and consideration of order of stiffest axes in the lateral, oblique and extension directions, respectively, should aid in the development of head and neck injury

  1. Design, development, and testing of the DCT Cassegrain instrument support assembly

    Science.gov (United States)

    Bida, Thomas A.; Dunham, Edward W.; Nye, Ralph A.; Chylek, Tomas; Oliver, Richard C.

    2012-09-01

    The 4.3m Discovery Channel Telescope delivers an f/6.1 unvignetted 0.5° field to its RC focal plane. In order to support guiding, wavefront sensing, and instrument installations, a Cassegrain instrument support assembly has been developed which includes a facility guider and wavefront sensor package (GWAVES) and multiple interfaces for instrumentation. A 2-element, all-spherical, fused-silica corrector compensates for field curvature and astigmatism over the 0.5° FOV, while reducing ghost pupil reflections to minimal levels. Dual roving GWAVES camera probes pick off stars in the outer annulus of the corrected field, providing simultaneous guiding and wavefront sensing for telescope operations. The instrument cube supports 5 co-mounted instruments with rapid feed selection via deployable fold mirrors. The corrected beam passes through a dual filter wheel before imaging with the 6K x 6K single CCD of the Large Monolithic Imager (LMI). We describe key development strategies for the DCT Cassegrain instrument assembly and GWAVES, including construction of a prime focus test assembly with wavefront sensor utilized in fall 2011 to begin characterization of the DCT primary mirror support. We also report on 2012 on-sky test results of wavefront sensing, guiding, and imaging with the integrated Cassegrain cube.

  2. Standards for radiation protection instrumentation: design of safety standards and testing procedures

    International Nuclear Information System (INIS)

    Meissner, Frank

    2008-01-01

    This paper describes by means of examples the role of safety standards for radiation protection and the testing and qualification procedures. The development and qualification of radiation protection instrumentation is a significant part of the work of TUV NORD SysTec, an independent expert organisation in Germany. The German Nuclear Safety Standards Commission (KTA) establishes regulations in the field of nuclear safety. The examples presented may be of importance for governments and nuclear safety authorities, for nuclear operators and for manufacturers worldwide. They demonstrate the advantage of standards in the design of radiation protection instrumentation for new power plants, in the upgrade of existing instrumentation to nuclear safety standards or in the application of safety standards to newly developed equipment. Furthermore, they show how authorities may proceed when safety standards for radiation protection instrumentation are not yet established or require actualization. (author)

  3. Methods and Models of Market Risk Stress-Testing of the Portfolio of Financial Instruments

    Directory of Open Access Journals (Sweden)

    Alexander M. Karminsky

    2015-01-01

    Full Text Available Amid instability of financial markets and macroeconomic situation the necessity of improving bank risk-management instrument arises. New economic reality defines the need for searching for more advanced approaches of estimating banks vulnerability to exceptional, but plausible events. Stress-testing belongs to such instruments. The paper reviews and compares the models of market risk stress-testing of the portfolio of different financial instruments. These days the topic of the paper is highly acute due to the fact that now stress-testing is becoming an integral part of anticrisis risk-management amid macroeconomic instability and appearance of new risks together with close interest to the problem of risk-aggregation. The paper outlines the notion of stress-testing and gives coverage of goals, functions of stress-tests and main criteria for market risk stress-testing classification. The paper also stresses special aspects of scenario analysis. Novelty of the research is explained by elaborating the programme of aggregated complex multifactor stress-testing of the portfolio risk based on scenario analysis. The paper highlights modern Russian and foreign models of stress-testing both on solo-basis and complex. The paper lays emphasis on the results of stress-testing and revaluations of positions for all three complex models: methodology of the Central Bank of stress-testing portfolio risk, model relying on correlations analysis and copula model. The models of stress-testing on solo-basis are different for each financial instrument. Parametric StressVaR model is applicable to shares and options stress-testing;model based on "Grek" indicators is used for options; for euroobligation regional factor model is used. Finally some theoretical recommendations about managing market risk of the portfolio are given.

  4. The Design and Development of Driving Game as an Evaluation Instrument for Driving License Test

    OpenAIRE

    Abdul Hadi Abdul Razak; Mohd Hairy Manap

    2013-01-01

    The focus of this paper is to highlight the design and development of an educational game prototype as an evaluation instrument for the Malaysia driving license static test. This educational game brings gaming technology into the conventional objective static test to make it more effective, real and interesting. From the feeling of realistic, the future driver can learn something, memorized and use it in the real life. The current online objective static test only make th...

  5. Technical Note: Validation of Odin/SMR limb observations of ozone, comparisons with OSIRIS, POAM III, ground-based and balloon-borne instruments

    Directory of Open Access Journals (Sweden)

    F. Jégou

    2008-06-01

    Full Text Available The Odin satellite carries two instruments capable of determining stratospheric ozone profiles by limb sounding: the Sub-Millimetre Radiometer (SMR and the UV-visible spectrograph of the OSIRIS (Optical Spectrograph and InfraRed Imager System instrument. A large number of ozone profiles measurements were performed during six years from November 2001 to present. This ozone dataset is here used to make quantitative comparisons with satellite measurements in order to assess the quality of the Odin/SMR ozone measurements. In a first step, we compare Swedish SMR retrievals version 2.1, French SMR ozone retrievals version 222 (both from the 501.8 GHz band, and the OSIRIS retrievals version 3.0, with the operational version 4.0 ozone product from POAM III (Polar Ozone Atmospheric Measurement. In a second step, we refine the Odin/SMR validation by comparisons with ground-based instruments and balloon-borne observations. We use observations carried out within the framework of the Network for Detection of Atmospheric Composition Change (NDACC and balloon flight missions conducted by the Canadian Space Agency (CSA, the Laboratoire de Physique et de Chimie de l'{}Environnement (LPCE, Orléans, France, and the Service d'Aéronomie (SA, Paris, France. Coincidence criteria were 5° in latitude×10° in longitude, and 5 h in time in Odin/POAM III comparisons, 12 h in Odin/NDACC comparisons, and 72 h in Odin/balloons comparisons. An agreement is found with the POAM III experiment (10–60 km within −0.3±0.2 ppmv (bias±standard deviation for SMR (v222, v2.1 and within −0.5±0.2 ppmv for OSIRIS (v3.0. Odin ozone mixing ratio products are systematically slightly lower than the POAM III data and show an ozone maximum lower by 1–5 km in altitude. The comparisons with the NDACC data (10–34 km for ozonesonde, 10–50 km for lidar, 10–60 for microwave instruments yield a good agreement within −0.15±0.3 ppmv for the SMR data and −0.3±0.3 ppmv

  6. Method of case hardening depth testing by using multifunctional ultrasonic testing instrument

    International Nuclear Information System (INIS)

    Salchak, Y A; Sednev, D A; Ardashkin, I B; Kroening, M

    2015-01-01

    The paper describes usability of ultrasonic case hardening depth control applying standard instrument of ultrasonic inspections. The ultrasonic method of measuring the depth of the hardened layer is proposed. Experimental series within the specified and multifunctional ultrasonic equipment are performed. The obtained results are compared with the results of a referent method of analysis. (paper)

  7. Development of Welding and Instrumentation Technology for Nuclear Fuel Test Rod

    International Nuclear Information System (INIS)

    Joung, Chang Young; Ahn, Sung Ho; Heo, Sung Ho; Hong, Jin Tae; Kim, Ka Hye

    2013-01-01

    It is necessary to develop various types of welding, instrumentation and helium gas filling techniques that can conduct TIG spot welding exactly at a pin-hole of the end-cap on the nuclear fuel rod to fill up helium gas. The welding process is one of the most important among the instrumentation processes of the nuclear fuel test rod. To manufacture the nuclear fuel test rod, a precision welding system needs to be fabricated to develop various welding technologies of the fuel test rod jointing the various sensors and end-caps on a fuel cladding tube, which is charged with fuel pellets and component parts. We therefore designed and fabricated an orbital TIG welding system and a laser welding system. This paper describes not only some experiment results from weld tests for the parts of a nuclear fuel test rod, but also the contents for the instrumentation process of the dummy fuel test rod installed with the C-type T. C. A dummy nuclear fuel test rod was successfully fabricated with the welding and instrumentation technologies acquired with various tests. In the test results, the round welding has shown a good weldability at both the orbital TIG welding system and the fiber laser welding system. The spot welding to fill up helium gas has shown a good welding performance at a welding current of 30A, welding time of 0.4 sec and gap of 1 mm in a helium gas atmosphere. The soundness of the nuclear fuel test rod sealed by a mechanical sealing method was confirmed by helium leak tests and microstructural analyses

  8. Development of Welding and Instrumentation Technology for Nuclear Fuel Test Rod

    Energy Technology Data Exchange (ETDEWEB)

    Joung, Chang Young; Ahn, Sung Ho; Heo, Sung Ho; Hong, Jin Tae; Kim, Ka Hye [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    It is necessary to develop various types of welding, instrumentation and helium gas filling techniques that can conduct TIG spot welding exactly at a pin-hole of the end-cap on the nuclear fuel rod to fill up helium gas. The welding process is one of the most important among the instrumentation processes of the nuclear fuel test rod. To manufacture the nuclear fuel test rod, a precision welding system needs to be fabricated to develop various welding technologies of the fuel test rod jointing the various sensors and end-caps on a fuel cladding tube, which is charged with fuel pellets and component parts. We therefore designed and fabricated an orbital TIG welding system and a laser welding system. This paper describes not only some experiment results from weld tests for the parts of a nuclear fuel test rod, but also the contents for the instrumentation process of the dummy fuel test rod installed with the C-type T. C. A dummy nuclear fuel test rod was successfully fabricated with the welding and instrumentation technologies acquired with various tests. In the test results, the round welding has shown a good weldability at both the orbital TIG welding system and the fiber laser welding system. The spot welding to fill up helium gas has shown a good welding performance at a welding current of 30A, welding time of 0.4 sec and gap of 1 mm in a helium gas atmosphere. The soundness of the nuclear fuel test rod sealed by a mechanical sealing method was confirmed by helium leak tests and microstructural analyses.

  9. Testing concordance of instrumental variable effects in generalized linear models with application to Mendelian randomization

    Science.gov (United States)

    Dai, James Y.; Chan, Kwun Chuen Gary; Hsu, Li

    2014-01-01

    Instrumental variable regression is one way to overcome unmeasured confounding and estimate causal effect in observational studies. Built on structural mean models, there has been considerale work recently developed for consistent estimation of causal relative risk and causal odds ratio. Such models can sometimes suffer from identification issues for weak instruments. This hampered the applicability of Mendelian randomization analysis in genetic epidemiology. When there are multiple genetic variants available as instrumental variables, and causal effect is defined in a generalized linear model in the presence of unmeasured confounders, we propose to test concordance between instrumental variable effects on the intermediate exposure and instrumental variable effects on the disease outcome, as a means to test the causal effect. We show that a class of generalized least squares estimators provide valid and consistent tests of causality. For causal effect of a continuous exposure on a dichotomous outcome in logistic models, the proposed estimators are shown to be asymptotically conservative. When the disease outcome is rare, such estimators are consistent due to the log-linear approximation of the logistic function. Optimality of such estimators relative to the well-known two-stage least squares estimator and the double-logistic structural mean model is further discussed. PMID:24863158

  10. Kryptonate-based instrumentation development for automobile exhaust pollutants. Phase III report: design and construction of four (4) experimental models

    International Nuclear Information System (INIS)

    Goodman, P.; Donaghue, T.

    This phase of the program encompasses the design, construction and evaluation of four (4) prototype instruments for the detection of automobile exhaust pollutant. These instruments employ the radio release mechanism utilized by Panametrics in detection of various trace gases. The prototype instruments are of two (2) designs. One design is operable from a power source supplied by an automobile battery. The second design is operable from 110 volts AC power. Successful evaluation in the laboratory as well as with various automobiles were performed with both type instruments. Scale-up of the quantity of sensor material prepared introduced unexpected problems with respect to detection lifetime which were not satisfactorily resolved within the time and funds available to the program. Nevertheless, a Kryptonate-based instrument using a single detection method for the measurement of hydrocarbons, CO and NO/sub x/ as pollutants by automobile exhausts was shown to be operable with actual automobile exhausts, to provide more than adequate sensitivity for inspection purposes, and to provide response and recovery times for full scale reading in the range 10-15 secs. (auth)

  11. Tests of arc-welding-related EMI effects on startup instrumentation

    International Nuclear Information System (INIS)

    Qian, T.; Kalechstein, W.; Cosgrove, D.

    1996-01-01

    The tests described in this paper were conducted to characterize the effects that electromagnetic interference (EMI), from arc welding, has on startup instrumentation (SUI). This paper reviews the results of a literature search on EMI resulting from arc welding and gives the objective and scope of the tests conducted and describes the test equipment and setting, and test procedure and results. Are-welding-related EMI levels in an SUI system were measured to determine the dominant source of interference, the coupling path and the susceptible part of the SUI system. The effectiveness of easily implemented improvements in reducing the level of EMI in the SUI system were also tested. Recommendations are provided on how to eliminate or reduce the EMI effects on sensitive nuclear instruments. (author)

  12. Instrumentation of fuel safety test rods of the PWR system in the Phebus reactor

    International Nuclear Information System (INIS)

    Schley, Robert; Leveque, J.P.; Aujollet, J.M.; Dutraive, Pierre; Colome, Jean; Bouly, J.C.

    1979-01-01

    The tests were performed in an experimental cell centred in the core of the PHEBUS water reactor of 50 MW. The CEA make two types of apparatus for testing the safety of PWR fuel. One is for testing a single fuel stick and the other a bunch of 25 sticks. The instrumentation described enables the main parameters of the test to be known: temperatures of the fuel - central temperature of the UO 2 - cladding surface temperatures; temperature of the cooling circuits - thermal balance - temperatures of the structures, etc.; coolant pressure; internal pressure of the fuel sticks; direction and flow rate of the fluid. This instrumentation and the technological problems to be overcome are described and the results of the first tests carried out are given [fr

  13. Development status of irradiation devices and instrumentation for material and nuclear fuel irradiation tests in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Sohn, Jae Min; Choo, Kee Nam [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-04-15

    The High flux Advanced Neutron Application ReactOr (HANARO), an open-tank-in-pool type reactor, is one of the multi-purpose research reactors in the world. Since the commencement of HANARO's operations in 1995, a significant number of experimental facilities have been developed and installed at HANARO, and continued efforts to develop more facilities are in progress. Owing to the stable operation of the reactor and its frequent utilization, more experimental facilities are being continuously added to satisfy various fields of study and diverse applications. The irradiation testing equipment for nuclear fuels and materials at HANARO can be classified into capsules and the Fuel Test Loop (FTL). Capsules for irradiation tests of nuclear fuels in HANARO have been developed for use under the dry conditions of the coolant and materials at HANARO and are now successfully utilized to perform irradiation tests. The FTL can be used to conduct irradiation testing of a nuclear fuel under the operating conditions of commercial nuclear power plants. During irradiation tests conducted using these capsules in HANARO, instruments such as the thermocouple, Linear Variable Differential Transformer (LVDT), small heater, Fluence Monitor (F/M) and Self-Powered Neutron Detector (SPND) are used to measure various characteristics of the nuclear fuel and irradiated material. This paper describes not only the status of HANARO and the status and perspective of irradiation devices and instrumentation for carrying out nuclear fuel and material tests in HANARO but also some results from instrumentation during irradiation tests

  14. Post-test analysis of ROSA-III experiment Run 702

    International Nuclear Information System (INIS)

    Koizumi, Yasuo; Kikuchi, Osamu; Soda, Kunihisa

    1980-01-01

    The purpose of the ROSA-III experiment with a scaled BWR test facility is to examine primary coolant thermal-hydraulic behavior and performance of ECCS during a posturated loss-of-coolant accident of BWR. The results provide information for verification and improvement of reactor safety analysis codes. Run 702 assumed a 200% split break at the recirculation pump suction line under an average core power without ECCS activation. Post - test analysis of the Run 702 experiment was made with computer code RELAP4J. Agreement of the calculated system pressure and the experiment one was good. However, the calculated heater surface temperatures were higher than the measured ones. Also, the axial temperature distribution was different in tendency from the experimental one. From these results, the necessity was indicated of improving the analytical model of void distribution in the core and the nodalization in the pressure vassel, in order to make the analysis more realistic. And also, the need of characteristic test was indicated for ROSA-III test facility components, such as jet pump and piping form loss coefficient; likewise, flow rate measurements must be increased and refined. (author)

  15. Lower extremity functional tests and risk of injury in division iii collegiate athletes.

    Science.gov (United States)

    Brumitt, Jason; Heiderscheit, Bryan C; Manske, Robert C; Niemuth, Paul E; Rauh, Mitchell J

    2013-06-01

    Functional tests have been used primarily to assess an athlete's fitness or readiness to return to sport. The purpose of this prospective cohort study was to determine the ability of the standing long jump (SLJ) test, the single-leg hop (SLH) for distance test, and the lower extremity functional test (LEFT) as preseason screening tools to identify collegiate athletes who may be at increased risk for a time-loss sports-related low back or lower extremity injury. A total of 193 Division III athletes from 15 university teams (110 females, age 19.1 ± 1.1 y; 83 males, age 19.5 ± 1.3 y) were tested prior to their sports seasons. Athletes performed the functional tests in the following sequence: SLJ, SLH, LEFT. The athletes were then prospectively followed during their sports season for occurrence of low back or LE injury. Female athletes who completed the LEFT in $118 s were 6 times more likely (OR=6.4, 95% CI: 1.3, 31.7) to sustain a thigh or knee injury. Male athletes who completed the LEFT in #100 s were more likely to experience a time-loss injury to the low back or LE (OR=3.2, 95% CI: 1.1, 9.5) or a foot or ankle injury (OR=6.7, 95% CI: 1.5, 29.7) than male athletes who completed the LEFT in 101 s or more. Female athletes with a greater than 10% side-to-side asymmetry between SLH distances had a 4-fold increase in foot or ankle injury (cut point: >10%; OR=4.4, 95% CI: 1.2, 15.4). Male athletes with SLH distances (either leg) at least 75% of their height had at least a 3-fold increase (OR=3.6, 95% CI: 1.2, 11.2 for the right LE; OR=3.6, 95% CI: 1.2, 11.2 for left LE) in low back or LE injury. The LEFT and the SLH tests appear useful in identifying Division III athletes at risk for a low back or lower extremity sports injury. Thus, these tests warrant further consideration as preparticipatory screening examination tools for sport injury in this population. The single-leg hop for distance and the lower extremity functional test, when administered to Division III

  16. Geotechnical instrumentation requirements for atdepth testing and repository monitoring in tuff

    International Nuclear Information System (INIS)

    Zimmerman, R.M.

    1983-01-01

    This paper outlines geotechnical instrumentation requirements for the possible establishment of a nuclear waste repository in tuff on the Nevada Test Site (NTS). The Nuclear Regulatory Commission (NRC) has specified a continuing program to confirm performance during the operational period of the repository, which could last 50 years. Minimum required geotechnical measurements for confirmation of performance include thermal and thermomechanical responses; changes in stress, strain, and displacements; and pore pressure and groundwater flow characteristics. Conditions expected in tuff are: maximum rock temperatures of less than 250 0 C, stresses less than 100 MPa, strains between + or -0.01 mm/mm, and pore pressures less than 35 KPa in the unsaturated zone where hydraulic head is not the primary contributor. The paper describes instrumentation needed to make the desired measurements. In general, the instrumentation and data system are required to be stable and reliable for tens of years. Designs must consider requirements for temperature stability, temperature expansion compensation, moisture resistance, and long-term durability in mining-type environments. Severe requirements such as these suggest consideration of techniques for in-situ replacement of instrumentation. State-of-the-art instrumentation is briefly described along with a discussion of needs for refinement, replacement/recalibration and instrumentation development

  17. Validation of an Instrument to Measure High School Students' Attitudes toward Fitness Testing

    Science.gov (United States)

    Mercier, Kevin; Silverman, Stephen

    2014-01-01

    Purpose: The purpose of this investigation was to develop an instrument that has scores that are valid and reliable for measuring students' attitudes toward fitness testing. Method: The method involved the following steps: (a) an elicitation study, (b) item development, (c) a pilot study, and (d) a validation study. The pilot study included 427…

  18. Development and testing of a cross-culturally valid instrument: food-related life style

    DEFF Research Database (Denmark)

    Brunsø, Karen; Grunert, Klaus G.

    1995-01-01

    -culturaly valid way. To this end we have developed a pool of 202 items, collected data in three countries, and have constructed scales based on cross-culturally stable factor patterns. We have then applie set of scales to a fourth country, in order to further test the cross-cultural validity of the instrument....

  19. Submicronic Particle Measurement Instrumentation Test Bench Data Acquisition and Control System

    International Nuclear Information System (INIS)

    Alberdi, J.; Barcala, J. M.; Sanz, D.; Gomez, F. J.; Molinero, A.; Navarrete, J. J.

    1999-01-01

    This document describes the SAD-100 system characteristics. The unit makes the instrumentation test bench data acquisition and control, SAD-100 was designed and developed by Electronic and Automation Area (CIEMAT) and Aerosol Technology in Energy Generation Project (CIEMAT). (Author) 2 refs

  20. Testing Instrumentation Validity for Measuring Teachers' Attitudes toward Manipulative Use in the Elementary Classroom

    Science.gov (United States)

    McIntosh, Gina Valdengo

    2012-01-01

    In this study a survey instrument was developed to test elementary teachers' attitudes towards incorporating manipulatives in their math lessons frequently. Though the benefits of using math manipulatives has been reported, there seems to be a disconnect between the benefits of manipulative use and the number of teachers integrating them in their…

  1. Validation of an Instrument and Testing Protocol for Measuring the Combinatorial Analysis Schema.

    Science.gov (United States)

    Staver, John R.; Harty, Harold

    1979-01-01

    Designs a testing situation to examine the presence of combinatorial analysis, to establish construct validity in the use of an instrument, Combinatorial Analysis Behavior Observation Scheme (CABOS), and to investigate the presence of the schema in young adolescents. (Author/GA)

  2. Building the BIKE: Development and Testing of the Biotechnology Instrument for Knowledge Elicitation (BIKE)

    Science.gov (United States)

    Witzig, Stephen B.; Rebello, Carina M.; Siegel, Marcelle A.; Freyermuth, Sharyn K.; Izci, Kemal; McClure, Bruce

    2014-10-01

    Identifying students' conceptual scientific understanding is difficult if the appropriate tools are not available for educators. Concept inventories have become a popular tool to assess student understanding; however, traditionally, they are multiple choice tests. International science education standard documents advocate that assessments should be reform based, contain diverse question types, and should align with instructional approaches. To date, no instrument of this type targeting student conceptions in biotechnology has been developed. We report here the development, testing, and validation of a 35-item Biotechnology Instrument for Knowledge Elicitation (BIKE) that includes a mix of question types. The BIKE was designed to elicit student thinking and a variety of conceptual understandings, as opposed to testing closed-ended responses. The design phase contained nine steps including a literature search for content, student interviews, a pilot test, as well as expert review. Data from 175 students over two semesters, including 16 student interviews and six expert reviewers (professors from six different institutions), were used to validate the instrument. Cronbach's alpha on the pre/posttest was 0.664 and 0.668, respectively, indicating the BIKE has internal consistency. Cohen's kappa for inter-rater reliability among the 6,525 total items was 0.684 indicating substantial agreement among scorers. Item analysis demonstrated that the items were challenging, there was discrimination among the individual items, and there was alignment with research-based design principles for construct validity. This study provides a reliable and valid conceptual understanding instrument in the understudied area of biotechnology.

  3. Apollo experience report: Development flight instrumentation. [telemetry equipment for space flight test program

    Science.gov (United States)

    Farmer, N. B.

    1974-01-01

    Development flight instrumentation was delivered for 25 Apollo vehicles as Government-furnished equipment. The problems and philosophies of an activity that was concerned with supplying telemetry equipment to a space-flight test program are discussed. Equipment delivery dates, system-design details, and flight-performance information for each mission also are included.

  4. Testing the Solar Probe Cup, an Instrument Designed to Touch the Sun

    Science.gov (United States)

    Whittlesey, Phyllis L.; Case, Anthony W.; Kasper, Justin Christophe; Wright, Kenneth H., Jr.; Alterman, Ben; Cirtain, Jonathan W.; Bookbinder, Jay; Korreck, Kelly E.; Stevens, Michael Louis

    2014-01-01

    Solar Probe Plus will be the first, fastest, and closest mission to the sun, providing the first direct sampling of the sub-Alfvenic corona. The Solar Probe Cup (SPC) is a unique re-imagining of the traditional Faraday Cup design and materials for immersion in this high temperature environment. Sending an instrument of this type into a never-seen particle environment requires extensive characterization prior to launch to establish sufficient measurement accuracy and instrument response. To reach this end, a slew of tests for allowing SPC to see ranges of appropriate ions and electrons, as well as a facility that reproduces solar photon spectra and fluxes for this mission. Having already tested the SPC at flight like temperatures with no significant modification of the noise floor, we recently completed a round of particle testing to see if the deviations in Faraday Cup design fundamentally change the operation of the instrument. Results and implications from these tests will be presented, as well as performance comparisons to cousin instruments such as those on the WIND spacecraft.

  5. Status Report on Efforts to Enhance Instrumentation to Support Advanced Test Reactor Irradiations

    Energy Technology Data Exchange (ETDEWEB)

    J. L. Rempe; D. L. Knudson; J. E. Daw

    2011-03-01

    The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support U.S. leadership in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR NSUF facilitates basic and applied nuclear research and development, further advancing the nation's energy security needs. A key component of the ATR NSUF effort is to prove new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. To address this need, an assessment of instrumentation available and under-development at other test reactors was completed. Based on this review, recommendations were made with respect to what instrumentation is needed at the ATR; and a strategy was developed for obtaining these sensors. In 2009, a report was issued documenting this program’s strategy and initial progress toward accomplishing program objectives. In 2009, a report was issued documenting this instrumentation development strategy and initial progress toward accomplishing instrumentation development program objectives. This document reports progress toward implementing this strategy in 2010.

  6. The test beamline of the European Spallation Source – Instrumentation development and wavelength frame multiplication

    International Nuclear Information System (INIS)

    Woracek, R.; Hofmann, T.; Bulat, M.; Sales, M.; Habicht, K.; Andersen, K.; Strobl, M.

    2016-01-01

    The European Spallation Source (ESS), scheduled to start operation in 2020, is aiming to deliver the most intense neutron beams for experimental research of any facility worldwide. Its long pulse time structure implies significant differences for instrumentation compared to other spallation sources which, in contrast, are all providing short neutron pulses. In order to enable the development of methods and technology adapted to this novel type of source well in advance of the first instruments being constructed at ESS, a test beamline (TBL) was designed and built at the BER II research reactor at Helmholtz-Zentrum Berlin (HZB). Operating the TBL shall provide valuable experience in order to allow for a smooth start of operations at ESS. The beamline is capable of mimicking the ESS pulse structure by a double chopper system and provides variable wavelength resolution as low as 0.5% over a wide wavelength band between 1.6 Å and 10 Å by a dedicated wavelength frame multiplication (WFM) chopper system. WFM is proposed for several ESS instruments to allow for flexible time-of-flight resolution. Hence, ESS will benefit from the TBL which offers unique possibilities for testing methods and components. This article describes the main capabilities of the instrument, its performance as experimentally verified during the commissioning, and its relevance to currently starting ESS instrumentation projects.

  7. Status Report on Efforts to Enhance Instrumentation to Support Advanced Test Reactor Irradiations

    International Nuclear Information System (INIS)

    Rempe, J.L.; Knudson, D.L.; Daw, J.E.

    2011-01-01

    The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support U.S. leadership in nuclear science and technology. By attracting new research users - universities, laboratories, and industry - the ATR NSUF facilitates basic and applied nuclear research and development, further advancing the nation's energy security needs. A key component of the ATR NSUF effort is to prove new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. To address this need, an assessment of instrumentation available and under-development at other test reactors was completed. Based on this review, recommendations were made with respect to what instrumentation is needed at the ATR; and a strategy was developed for obtaining these sensors. In 2009, a report was issued documenting this program's strategy and initial progress toward accomplishing program objectives. In 2009, a report was issued documenting this instrumentation development strategy and initial progress toward accomplishing instrumentation development program objectives. This document reports progress toward implementing this strategy in 2010.

  8. The test beamline of the European Spallation Source – Instrumentation development and wavelength frame multiplication

    Energy Technology Data Exchange (ETDEWEB)

    Woracek, R., E-mail: robin.woracek@esss.se [European Spallation Source ESS ERIC, P.O. Box 176, SE-22100 Lund (Sweden); Hofmann, T.; Bulat, M. [Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner Platz 1, 14109 Berlin (Germany); Sales, M. [Technical University of Denmark, Fysikvej, 2800 Kgs. Lyngby (Denmark); Habicht, K. [Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner Platz 1, 14109 Berlin (Germany); Andersen, K. [European Spallation Source ESS ERIC, P.O. Box 176, SE-22100 Lund (Sweden); Strobl, M. [European Spallation Source ESS ERIC, P.O. Box 176, SE-22100 Lund (Sweden); Technical University of Denmark, Fysikvej, 2800 Kgs. Lyngby (Denmark)

    2016-12-11

    The European Spallation Source (ESS), scheduled to start operation in 2020, is aiming to deliver the most intense neutron beams for experimental research of any facility worldwide. Its long pulse time structure implies significant differences for instrumentation compared to other spallation sources which, in contrast, are all providing short neutron pulses. In order to enable the development of methods and technology adapted to this novel type of source well in advance of the first instruments being constructed at ESS, a test beamline (TBL) was designed and built at the BER II research reactor at Helmholtz-Zentrum Berlin (HZB). Operating the TBL shall provide valuable experience in order to allow for a smooth start of operations at ESS. The beamline is capable of mimicking the ESS pulse structure by a double chopper system and provides variable wavelength resolution as low as 0.5% over a wide wavelength band between 1.6 Å and 10 Å by a dedicated wavelength frame multiplication (WFM) chopper system. WFM is proposed for several ESS instruments to allow for flexible time-of-flight resolution. Hence, ESS will benefit from the TBL which offers unique possibilities for testing methods and components. This article describes the main capabilities of the instrument, its performance as experimentally verified during the commissioning, and its relevance to currently starting ESS instrumentation projects.

  9. Recirculation pump suction line 2.8% break integral test at ROSA-III with HPCS failure, RUN 984

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Anoda, Yoshinari; Tasaka, Kanji; Kumamaru, Hiroshige; Nakamura, Hideo; Yonomoto, Taisuke; Murata, Hideo; Shiba, Masayoshi

    1984-06-01

    This report presents the experimental data of 2.8% suction line break test RUN 984 at ROSA-III, which was conducted as one of counterpart tests to FIST program sponsored by GE, EPRI and USNRC. The similarity study between the ROSA-III and FIST tests is on the way. The report also presents the information on the ROSA-III test facility, experiment results and the effects of the ADS flow rate and the MSIV trip level comparing with the previously conducted ROSA-III small break tests, RUNs 920 and 922. Major conclusions obtained are as follows. (1) Change of the MSIV trip level from L2 to L1 gives delay of MSIV closure and longer actuation of pressure control system in a small break LOCA. (2) Larger ADS flow gives faster depressurization rate and earlier ECCS actuation, which results in shorter fuel rod dryout period and lower PCT. (author)

  10. An Application of Graphical Approach to Construct Multiple Testing Procedure in a Hypothetical Phase III Design

    Directory of Open Access Journals (Sweden)

    Naitee eTing

    2014-01-01

    Full Text Available Many multiple testing procedures (MTP have been developed in recent years. Among these new procedures, the graphical approach is flexible and easy to communicate with non-statisticians. A hypothetical Phase III clinical trial design is introduced in this manuscript to demonstrate how graphical approach can be applied in clinical product development. In this design, an active comparator is used. It is thought that this test drug under development could potentially be superior to this comparator. For comparison of efficacy, the primary endpoint is well established and widely accepted by regulatory agencies. However, an important secondary endpoint based on Phase II findings looks very promising. The target dose may have a good opportunity to deliver superiority to the comparator. Furthermore, a lower dose is included in case the target dose may demonstrate potential safety concerns. This Phase III study is designed as a non-inferiority trial with two doses, and two endpoints. This manuscript will illustrate how graphical approach is applied to this design in handling multiple testing issues.

  11. Carbon Dioxide Washout Testing Using Various Inlet Vent Configurations in the Mark-III Space Suit

    Science.gov (United States)

    Korona, F. Adam; Norcross, Jason; Conger, Bruce; Navarro, Moses

    2014-01-01

    Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy, and eventually unconsciousness or even death. Symptoms depend on several factors including inspired partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject, and physiological differences between subjects. Computational Fluid Dynamics (CFD) analysis has predicted that the configuration of the suit inlet vent has a significant effect on oronasal CO2 concentrations. The main objective of this test was to characterize inspired oronasal ppCO2 for a variety of inlet vent configurations in the Mark-III suit across a range of workload and flow rates. Data and trends observed during testing along with refined CFD models will be used to help design an inlet vent configuration for the Z-2 space suit. The testing methodology used in this test builds upon past CO2 washout testing performed on the Z-1 suit, Rear Entry I-Suit, and the Enhanced Mobility Advanced Crew Escape Suit. Three subjects performed two test sessions each in the Mark-III suit to allow for comparison between tests. Six different helmet inlet vent configurations were evaluated during each test session. Suit pressure was maintained at 4.3 psid. Suited test subjects walked on a treadmill to generate metabolic workloads of approximately 2000 and 3000 BTU/hr. Supply airflow rates of 6 and 4 actual cubic feet per minute were tested at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the CO2 production measured by an additional gas analyzer at the air outlet from the suit. Real-time metabolic rate measurements were used to adjust the treadmill workload to meet

  12. Preliminary Results From a Heavily Instrumented Engine Ice Crystal Icing Test in a Ground Based Altitude Test Facility

    Science.gov (United States)

    Flegel, Ashlie B.; Oliver, Michael J.

    2016-01-01

    Preliminary results from the heavily instrumented ALF502R-5 engine test conducted in the NASA Glenn Research Center Propulsion Systems Laboratory are discussed. The effects of ice crystal icing on a full scale engine is examined and documented. This same model engine, serial number LF01, was used during the inaugural icing test in the Propulsion Systems Laboratory facility. The uncommanded reduction of thrust (rollback) events experienced by this engine in flight were simulated in the facility. Limited instrumentation was used to detect icing on the LF01 engine. Metal temperatures on the exit guide vanes and outer shroud and the load measurement were the only indicators of ice formation. The current study features a similar engine, serial number LF11, which is instrumented to characterize the cloud entering the engine, detect/characterize ice accretion, and visualize the ice accretion in the region of interest. Data were acquired at key LF01 test points and additional points that explored: icing threshold regions, low altitude, high altitude, spinner heat effects, and the influence of varying the facility and engine parameters. For each condition of interest, data were obtained from some selected variations of ice particle median volumetric diameter, total water content, fan speed, and ambient temperature. For several cases the NASA in-house engine icing risk assessment code was used to find conditions that would lead to a rollback event. This study further helped NASA develop necessary icing diagnostic instrumentation, expand the capabilities of the Propulsion Systems Laboratory, and generate a dataset that will be used to develop and validate in-house icing prediction and risk mitigation computational tools. The ice accretion on the outer shroud region was acquired by internal video cameras. The heavily instrumented engine showed good repeatability of icing responses when compared to the key LF01 test points and during day-to-day operation. Other noticeable

  13. Thermal and Alignment Analysis of the Instrument-Level ATLAS Thermal Vacuum Test

    Science.gov (United States)

    Bradshaw, Heather

    2012-01-01

    This paper describes the thermal analysis and test design performed in preparation for the ATLAS thermal vacuum test. NASA's Advanced Topographic Laser Altimeter System (ATLAS) will be flown as the sole instrument aboard the Ice, Cloud, and land Elevation Satellite-2 (ICESat-2). It will be used to take measurements of topography and ice thickness for Arctic and Antarctic regions, providing crucial data used to predict future changes in worldwide sea levels. Due to the precise measurements ATLAS is taking, the laser altimeter has very tight pointing requirements. Therefore, the instrument is very sensitive to temperature-induced thermal distortions. For this reason, it is necessary to perform a Structural, Thermal, Optical Performance (STOP) analysis not only for flight, but also to ensure performance requirements can be operationally met during instrument-level thermal vacuum testing. This paper describes the thermal model created for the chamber setup, which was used to generate inputs for the environmental STOP analysis. This paper also presents the results of the STOP analysis, which indicate that the test predictions adequately replicate the thermal distortions predicted for flight. This is a new application of an existing process, as STOP analyses are generally performed to predict flight behavior only. Another novel aspect of this test is that it presents the opportunity to verify pointing results of a STOP model, which is not generally done. It is possible in this case, however, because the actual pointing will be measured using flight hardware during thermal vacuum testing and can be compared to STOP predictions.

  14. Static Load Test on Instrumented Pile – Field Data and Numerical Simulations

    Directory of Open Access Journals (Sweden)

    Krasiński Adam

    2017-09-01

    Full Text Available Static load tests on foundation piles are generally carried out in order to determine load – the displacement characteristic of the pile head. For standard (basic engineering practices this type of test usually provides enough information. However, the knowledge of force distribution along the pile core and its division into the friction along the shaft and the resistance under the base can be very useful. Such information can be obtained by strain gage pile instrumentation [1]. Significant investigations have been completed on this technology, proving its utility and correctness [8], [10], [12]. The results of static tests on instrumented piles are not easy to interpret. There are many factors and processes affecting the final outcome. In order to understand better the whole testing process and soil-structure behavior some investigations and numerical analyses were done. In the paper, real data from a field load test on instrumented piles is discussed and compared with numerical simulation of such a test in similar conditions. Differences and difficulties in the results interpretation with their possible reasons are discussed. Moreover, the authors used their own analytical solution for more reliable determination of force distribution along the pile. The work was presented at the XVII French-Polish Colloquium of Soil and Rock Mechanics, Łódź, 28–30 November 2016.

  15. Static Load Test on Instrumented Pile - Field Data and Numerical Simulations

    Science.gov (United States)

    Krasiński, Adam; Wiszniewski, Mateusz

    2017-09-01

    Static load tests on foundation piles are generally carried out in order to determine load - the displacement characteristic of the pile head. For standard (basic) engineering practices this type of test usually provides enough information. However, the knowledge of force distribution along the pile core and its division into the friction along the shaft and the resistance under the base can be very useful. Such information can be obtained by strain gage pile instrumentation [1]. Significant investigations have been completed on this technology, proving its utility and correctness [8], [10], [12]. The results of static tests on instrumented piles are not easy to interpret. There are many factors and processes affecting the final outcome. In order to understand better the whole testing process and soil-structure behavior some investigations and numerical analyses were done. In the paper, real data from a field load test on instrumented piles is discussed and compared with numerical simulation of such a test in similar conditions. Differences and difficulties in the results interpretation with their possible reasons are discussed. Moreover, the authors used their own analytical solution for more reliable determination of force distribution along the pile. The work was presented at the XVII French-Polish Colloquium of Soil and Rock Mechanics, Łódź, 28-30 November 2016.

  16. Results of the first tests of the SIDRA satellite-borne instrument breadboard model

    International Nuclear Information System (INIS)

    Dudnik, O.V.; Kurbatov, E.V.; Avilov, A.M.; Titov, K.G.; Prieto, M; Sanchez, S.; Spassky, A.V.; Sylwester, J.; Gburek, S.; Podgorski, P.

    2013-01-01

    In this work, the results of the calibration of the solid-state detectors and electronic channels of the SIDRA satellite borne energetic charged particle spectrometer-telescope breadboard model are presented. The block schemes and experimental equipment used to conduct the thermal vacuum and electromagnetic compatibility tests of the assemblies and modules of the compact satellite equipment are described. The results of the measured thermal conditions of operation of the signal analog and digital processing critical modules of the SIDRA instrument prototype are discussed. Finally, the levels of conducted interference generated by the instrument model in the primary vehicle-borne power circuits are presented.

  17. Development of Induction Brazing System for Sealing Instrumentation Feed through Part of Nuclear Fuel Test Rig

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jintae; Kim, Kahye; Heo, Sungho; Ahn, Sungho; Joung, Changyoung; Son, Kwangjae; Jung, Yangil [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-12-15

    To test the performance of nuclear fuels, coolant needs to be circulated through the test rig installed in the test loop. Because the pressure and temperature of the coolant is 15.5 MPa and 300 .deg. C respectively, coolant sealing is one of the most important processes in fabricating a nuclear fuel test rig. In particular, 15 instrumentation cables installed in a test rig pass through the pressure boundary, and brazing is generally applied as a sealing method. In this study, an induction brazing system has been developed using a high frequency induction heater including a vacuum chamber. For application in the nuclear field, BNi2 should be used as a paste, and optimal process variables for Ni brazing have been found by several case studies. The performance and soundness of the brazed components has been verified by a tensile test, cross section test, and sealing performance test.

  18. Proposal for a Universal Test Mirror for Characterization of Slope Measuring Instruments

    International Nuclear Information System (INIS)

    Yashchuk, Valeriy V.; McKinney, Wayne R.; Warwick, Tony; Noll, Tino; Siewert, Frank; Zeschke, Thomas; Geckeler, Ralf D.

    2007-01-01

    The development of third generation light sources like the Advanced Light Source (ALS) or BESSY II brought to a focus the need for high performance synchrotron optics with unprecedented tolerances for slope error and micro roughness. Proposed beam lines at Free Electron Lasers (FEL) require optical elements up to a length of one meter, characterized by a residual slope error in the range of 0.1mu rad (rms),and rms values of 0.1 nm for micro roughness. These optical elements must be inspected by highly accurate measuring instruments, providing a measurement uncertainty lower than the specified accuracy of the surface under test. It is essential that metrology devices in use at synchrotron laboratories be precisely characterized and calibrated to achieve this target. In this paper we discuss a proposal for a Universal Test Mirror (UTM) as a realization of a high performance calibration instrument. The instrument would provide an ideal calibration surface to replicate a redundant surface under test of redundant figure. The application of a sophisticated calibration instrument will allow the elimination of the majority of the systematic error from the error budget of an individual measurement of a particular optical element. We present the limitations of existing methods, initial UTM design considerations, possible calibration algorithms, and an estimation of the expected accuracy

  19. MK-III function tests in JOYO. Primary main cooling pump

    International Nuclear Information System (INIS)

    Isozaki, Kazunori; Saito, Takakazu; Sumino, Kouzo; Karube, Kouji; Terano, Toshihiro; Sakaba, Hideo; Nakai, Satoru

    2004-06-01

    MK-III function test (SKS-1) that was carried out from October 17, 2001 through October 23, 2001 using MK-III transition core configuration and MK-III function tests (SKS-2) was carried out from January 27, 2003 through February 13, 2003 using MK-III core configuration. The major function tests results of primary cooling system were shown as follows; (1) The stability of the primary main pump flow control system was confirmed on both CAS (cascade) mode and Man (manual) mode. Also no divergence of flow and revolution of the pump were observed at step flow change disturbance. (2) The main motor was shifted to run-back flow control operation in about 54 seconds after scram. The flow rate and pump revolution at run-back operation of A and B cooling system were 167 m 3 /h and 117 rpm, 185m 3 /h and 118 rpm respectively. The pump revolution was within the design target revolution 122 rpm ± 8 rpm and the flow was over the 10% of the rated flow. (3) The pony motor was engaged in operation in about 39 seconds after the primary main pump trip. The flow rate and pump revolution at the pony motor operation of A and B cooling system were 180 m 3 /h and 124 rpm, 190 m 3 /h and 123 rpm respectively. These values were satisfied the design low limit of 93 rpm and 10% of the rated flow. (4) Free flow coast down time constant was longer than 10 seconds that was design shortest time at both the primary pump trip and run-back operation. (5) Pump over flow column sodium levels of both A and B cooling system at rated operating condition were NL-1550 mm and, NL-1468 mm respectively and were lower than NL-1581 mm of the design value. This result shows the new IHX pressure loss estimation was conservative. (6) It was confirmed that the primary main pump could operate with out scram for up to 0.6 seconds of external power supply loss. (author)

  20. Optimized FFTF Acceptance Test Program covering Phases III, IV, and V

    International Nuclear Information System (INIS)

    Wykoff, W.R.; Jones, D.H.

    1977-03-01

    A detailed review of Phases III, IV, and V of the FFTF Acceptance Test Program has been completed. The purpose of this review was to formulate that test sequence which not only meets requirements for safe, reliable and useful operation of the plant, but also results in the earliest prudent demonstration of full-power performance. A test sequence based on the underlying assumption that sodium flows into the secondary sodium storage tank (T-44) no later than August 31, 1978, is described in detail. A time-scale which allows extra time to put systems and equipment into operation the first time, debugging, and learning how to operate most effectively has been superimposed on the test sequence. Time is not included for major equipment malfunctions. This test plan provides the basis for coordinating the many and varied activities and interfaces necessary for successful and timely execution of the FFTF Acceptance Test Program. In this report, the need dates have been identified for presently scheduled test articles and standard core components

  1. Generic System for Remote Testing and Calibration of Measuring Instruments: Security Architecture

    Science.gov (United States)

    Jurčević, M.; Hegeduš, H.; Golub, M.

    2010-01-01

    Testing and calibration of laboratory instruments and reference standards is a routine activity and is a resource and time consuming process. Since many of the modern instruments include some communication interfaces, it is possible to create a remote calibration system. This approach addresses a wide range of possible applications and permits to drive a number of different devices. On the other hand, remote calibration process involves a number of security issues due to recommendations specified in standard ISO/IEC 17025, since it is not under total control of the calibration laboratory personnel who will sign the calibration certificate. This approach implies that the traceability and integrity of the calibration process directly depends on the collected measurement data. The reliable and secure remote control and monitoring of instruments is a crucial aspect of internet-enabled calibration procedure.

  2. Mechanical design and vibro-acoustic testing of ultrathin carbon foils for a spacecraft instrument

    Energy Technology Data Exchange (ETDEWEB)

    Bernardin, John D [Los Alamos National Laboratory; Baca, Allen G [SNL

    2009-01-01

    IBEX-Hi is an electrostatic analyzer spacecraft instrument designed to measure the energy and flux distribution of energetic neutral atoms (ENAs) emanating from the interaction zone between the Earth's solar system and the Milky Way galaxy. A key element to this electro-optic instrument is an array of fourteen carbon foils that are used to ionize the ENAs. The foils are comprised of an ultrathin (50-100 {angstrom} thick) layer of carbon suspended across the surface of an electroformed Nickel wire screen, which in turn is held taught by a metal frame holder. The electro formed orthogonal screen has square wire elements, 12.7 {micro}m thick, with a pitch of 131.1 wires/cm. Each foil holder has an open aperture approximately 5 cm by 2.5 cm. Designing and implementing foil holders with such a large surface area has not been attempted for spaceflight in the past and has proven to be extremely challenging. The delicate carbon foils are subject to fatigue failure from the large acoustic and vibration loads that they will be exposed to during launch of the spacecraft. This paper describes the evolution of the foil holder design from previous space instrument applications to a flight-like IBEX-Hi prototype. Vibro-acoustic qualification tests of the IBEX-Hi prototype instrument and the resulting failure of several foils are summarized. This is followed by a discussion of iterative foil holder design modifications and laser vibrometer modal testing to support future fatigue failure analyses, along with additional acoustic testing of the IBEX-Hi prototype instrument. The results of these design and testing activities are merged and the resulting flight-like foil holder assembly is proposed.

  3. Computer aided instrumented Charpy test applied dynamic fracture toughness evaluation system

    International Nuclear Information System (INIS)

    Kobayashi, Toshiro; Niinomi, Mitsuo

    1986-01-01

    Micro computer aided data treatment system and personal computer aided data analysis system were applied to the traditional instrumented Charpy impact test system. The analysis of Charpy absorbed energy (E i , E p , E t ) and load (P y , P m ), and the evaluation of dynamic toughness through whole fracture process, i.e. J Id , J R curve and T mat was examined using newly developed computer aided instrumented Charpy impact test system. E i , E p , E t , P y and P m were effectively analyzed using moving average method and printed out automatically by micro computer aided data treatment system. J Id , J R curve and T mat could be measured by stop block test method. Then, J Id , J R curve and T mat were effectively estimated using compliance changing rate method and key curve method on the load-load point displacement curve of single fatigue cracked specimen by personal computer aided data analysis system. (author)

  4. Review Paper: Review of Instrumentation for Irradiation Testing of Nuclear Fuels and Materials

    International Nuclear Information System (INIS)

    Kim, Bong Goo; Rempe, Joy L.; Villard, Jean-Francois; Solstadd, Steinar

    2011-01-01

    Over 50 years of nuclear fuels and materials irradiation testing has led to many countries developing significant improvements in instrumentation to monitor physical parameters and to control the test conditions in material test reactors (MTRs). Recently, there is increased interest to irradiate new materials and reactor fuels for advanced pressurized water reactors and Gen-IV reactor systems, such as sodium-cooled fast reactors, very high temperature reactors, supercritical water-cooled reactors, and gas-cooled fast reactors. This review paper documents the current state of instrumentation technologies in MTRs in the world and summarizes ongoing research efforts to deploy new sensors. As described in this paper, a wide range of sensors is available to measure key parameters of interest during fuels and materials irradiations in MTRs. Ongoing development efforts focus on providing MTR users a wider range of parameter measurements with smaller, higher accuracy sensors.

  5. Development and design of a late-model fitness test instrument based on LabView

    Science.gov (United States)

    Xie, Ying; Wu, Feiqing

    2010-12-01

    Undergraduates are pioneers of China's modernization program and undertake the historic mission of rejuvenating our nation in the 21st century, whose physical fitness is vital. A smart fitness test system can well help them understand their fitness and health conditions, thus they can choose more suitable approaches and make practical plans for exercising according to their own situation. following the future trends, a Late-model fitness test Instrument based on LabView has been designed to remedy defects of today's instruments. The system hardware consists of fives types of sensors with their peripheral circuits, an acquisition card of NI USB-6251 and a computer, while the system software, on the basis of LabView, includes modules of user register, data acquisition, data process and display, and data storage. The system, featured by modularization and an open structure, is able to be revised according to actual needs. Tests results have verified the system's stability and reliability.

  6. Virtual instrumention-based linearity test platform for DCCT of digital power supply at SSRF

    International Nuclear Information System (INIS)

    Tang Junlong; Li Deming; Shen Tianjian; Liu Hong

    2008-01-01

    Based on virtual instrumentation, a reliable and effective test platform, performing instrument control, data acquisition and data recording, has been established to evaluate linearity of high performance DCCT (DC current transducer) for digital power supply at Shanghai Synchrotron Radiation Facility (SSRF). The software in LabVIEW language was developed to perform computer communication via serial communication (RS232) and GPIB, providing a friendly user interface to the linearity test platform. This makes it easy to test the linearity and control power on or off and current output of high-precision and high-current DC constant current output power supply. The experimental data, stored in an EXCEL file, can be processed to obtain DCCT linearity, and provide basis to further analyze DCCT performance in the future. (authors)

  7. Instrumented measurements on radioactive waste disposal containers during experimental drop testing - 59142

    International Nuclear Information System (INIS)

    Quercetti, Thomas; Musolff, Andre; Mueller, Karsten

    2012-01-01

    In context with disposal container safety assessment of containers for radioactive waste the German Federal Institute for Materials Research and Testing (BAM) performed numerous drop tests in the last years. The tests were accompanied by extensive and various measurement techniques especially by instrumented measurements with strain gages and accelerometers. The instrumentation of a specimen is an important tool to evaluate its mechanical behavior during impact. Test results as deceleration-time and strain-time functions constitute a main basis for the validation of assumptions in the safety analysis and for the evaluation of calculations based on finite-element methods. Strain gauges are useful to determine the time dependent magnitude of any deformation and the associated stresses. Accelerometers are widely used for the measuring of motion i.e. speed or the displacement of the rigid cask body, vibration and shock events. In addition high-speed video technique can be used to visualize and analyze the kinematical impact scenario by motion analysis. The paper describes some selected aspects on instrumented measurements and motion analysis in context with low level radioactive waste (LLW) container drop testing. (authors)

  8. Human-Robot Collaboration Dynamic Impact Testing and Calibration Instrument for Disposable Robot Safety Artifacts.

    Science.gov (United States)

    Dagalakis, Nicholas G; Yoo, Jae Myung; Oeste, Thomas

    2016-01-01

    The Dynamic Impact Testing and Calibration Instrument (DITCI) is a simple instrument with a significant data collection and analysis capability that is used for the testing and calibration of biosimulant human tissue artifacts. These artifacts may be used to measure the severity of injuries caused in the case of a robot impact with a human. In this paper we describe the DITCI adjustable impact and flexible foundation mechanism, which allows the selection of a variety of impact force levels and foundation stiffness. The instrument can accommodate arrays of a variety of sensors and impact tools, simulating both real manufacturing tools and the testing requirements of standards setting organizations. A computer data acquisition system may collect a variety of impact motion, force, and torque data, which are used to develop a variety of mathematical model representations of the artifacts. Finally, we describe the fabrication and testing of human abdomen soft tissue artifacts, used to display the magnitude of impact tissue deformation. Impact tests were performed at various maximum impact force and average pressure levels.

  9. Experimental analysis of the power curve sensitivity test series at ROSA-III

    International Nuclear Information System (INIS)

    Koizumi, Y.; Iriko, M.; Yonomoto, T.; Tasaka, K.

    1985-01-01

    The rig of safety assessment (ROSA)-III facility is a volumetrically scaled (1/424) boiling water reactor (BWR/6) system with an electrically heated core designed for integral LOCA and ECCS tests. Seven recirculation pump suction line break LOCA experiments were conducted at the ROSA-III facility in order to examine the effect of the initial stored heat of a fuel rod on the peak cladding temperature (PCT). The break size was changed from 200% to 5% in the test series and a failure of a high pressure core spray (HPCS) diesel generator was assumed. Three power curves which represented conservative, realistic and zero initial stored heat, respectively, were used. In a large break LOCA such as 200% or 50% breaks, the initial stored heat in a fuel rod has a large effect on the cladding surface temperature because core uncovery occurs before all the initial stored heat is released, whereas in a small break LOCA such as a 5% break little effect is observed because core uncovery occurs after the initial stored heat is released. The maximum PCTs for the conservative initial stored heat case was 925 K, obtained in the 50% break experiment, and that for the realistic initial stored heat case was 835 K, obtained in the 5% break experiment. (orig./HP)

  10. Effect of using heat-inactivated serum with the Abbott human T-cell lymphotropic virus type III antibody test.

    OpenAIRE

    Jungkind, D L; DiRenzo, S A; Young, S J

    1986-01-01

    The Abbott enzyme immunoassay (Abbott Laboratories, North Chicago, Ill.) for human T-cell lymphotropic virus type III (HTLV-III) antibody was evaluated to determine the effect of using heat-inactivated (56 degrees C for 30 min) serum as the sample. Each of 58 nonreactive serum samples gave a higher A492 value when tested after heat inactivation. Ten of the samples became reactive after heating. Heat-inactivated serum should not be used in the current Abbott HTLV-III antibody test, because thi...

  11. Standard practice for evaluating performance characteristics of ultrasonic Pulse-Echo testing instruments and systems without the use of electronic measurement instruments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This practice describes procedures for evaluating the following performance characteristics of ultrasonic pulse-echo examination instruments and systems: Horizontal Limit and Linearity; Vertical Limit and Linearity; Resolution - Entry Surface and Far Surface; Sensitivity and Noise; Accuracy of Calibrated Gain Controls. Evaluation of these characteristics is intended to be used for comparing instruments and systems or, by periodic repetition, for detecting long-term changes in the characteristics of a given instrument or system that may be indicative of impending failure, and which, if beyond certain limits, will require corrective maintenance. Instrument characteristics measured in accordance with this practice are expressed in terms that relate to their potential usefulness for ultrasonic testing. Instrument characteristics expressed in purely electronic terms may be measured as described in E1324. 1.2 Ultrasonic examination systems using pulsed-wave trains and A-scan presentation (rf or video) may be ev...

  12. Region III involvement in quality control and quality assurance of radon testing methods

    International Nuclear Information System (INIS)

    Coyle, F.T.

    1990-01-01

    Region III has set a goal of increasing the testing for radon by our residents. One approach to this goal, is to bolster the public's confidence in the testing laboratories. We believe that this can be done most effectively by assuring the quality of the measurements available to the public. All Proficient Laboratories and Pennsylvania Certified Laboratories have submitted a quality assurance (QA) program. A QA audit checklist has been developed which will be finalized and made available to the states in our Region. This paper deals with inspection, verification, and documentation of the various laboratories and their compliance with prudent measuring protocols and addresses the following items: Organization and responsibilities; Sampling procedures; Detector chain of custody; Measurement procedures, quality control checks; State certification and RMP; Data resection, validation, and reporting; Quality assurance reports to management; Interview and discussion of QA audit with responsible officer

  13. Addenbrooke's cognitive examination III: diagnostic utility for mild cognitive impairment and dementia and correlation with standardized neuropsychological tests.

    Science.gov (United States)

    Matias-Guiu, Jordi A; Cortés-Martínez, Ana; Valles-Salgado, Maria; Rognoni, Teresa; Fernández-Matarrubia, Marta; Moreno-Ramos, Teresa; Matías-Guiu, Jorge

    2017-01-01

    Addenbrooke's Cognitive Examination III (ACE-III) is a screening test that was recently validated for diagnosing dementia. Since it assesses attention, language, memory, fluency, and visuospatial function separately, it may also be useful for general neuropsychological assessments. The aim of this study was to analyze the tool's ability to detect early stages of Alzheimer's disease and to examine the correlation between ACE-III scores and scores on standardized neuropsychological tests. Our study included 200 participants categorized as follows: 25 healthy controls, 48 individuals with subjective memory complaints, 47 patients with amnestic mild cognitive impairment and 47 mild Alzheimer's disease, and 33 patients with other neurodegenerative diseases. The ACE-III memory and language domains were highly correlated with the neuropsychological tests specific to those domains (Pearson correlation coefficient of 0.806 for total delayed recall on the Free and Cued Selective Reminding Test vs. 0.744 on the Boston Naming Test). ACE-III scores discriminated between controls and patients with amnestic mild cognitive impairment (AUC: 0.906), and between controls and patients with mild Alzheimer's disease (AUC: 0.978). Our results suggest that ACE-III is a useful neuropsychological test for assessing the cognitive domains of attention, language, memory, and visuospatial function. It also enables detection of Alzheimer's disease in early stages.

  14. Automated systems help prevent operator error during [reactor] I and C [instrumentation and control] testing

    International Nuclear Information System (INIS)

    Courcoux, R.

    1989-01-01

    On a nuclear steam supply system, even a minor failure can involve actuation of the whole reactor protection system (RPS). To reduce the likelihood of human error leading to unwanted trips during the maintenance of instrumentation and control systems, Framatome has been developing and installing various automated testing systems. Such automated systems are particularly helpful when periodic tests with a potential for RPS actuation have to be carried out, or when the test is on the critical path for the refuelling outage. The Sensitive Channel Programme described is an example of the sort of work that has been done. (author)

  15. The apparent source size of type III radio bursts: Preliminary results by the STEREO/WAVES instruments

    Czech Academy of Sciences Publication Activity Database

    Krupař, Vratislav; Maksimovic, M.; Santolík, Ondřej; Cecconi, B.; Nguyen, Q. N.; Hoang, S.; Goetz, K.

    2010-01-01

    Roč. 1216, č. 1 (2010), s. 284-287 ISSN 0094-243X. [International Solar Wind Conference /12./. Saint-Milo, 21.06.2009-26.06.2009] R&D Projects: GA ČR GAP205/10/2279; GA AV ČR IAA301120601; GA MŠk ME09107 Institutional research plan: CEZ:AV0Z30420517 Keywords : WAVES Instrument * Solar Radio Emissions * Singular Value Decomposition technique Subject RIV: BL - Plasma and Gas Discharge Physics

  16. Re-irradiation tests of spent fuel at JMTR by means of re-instrumentation technique

    International Nuclear Information System (INIS)

    Nakamura, Jinichi; Shimizu, Michio; Endo, Yasuichi; Nabeya, Hideaki; Ichise, Kenichi; Saito, Junichi; Oshima, Kunio; Uetsuka, Hiroshi

    1999-01-01

    JAERI has developed re-irradiation test procedures of spent fuel irradiated at commercial reactor by means of re-instrumentation technique. Full length rods irradiated at commercial LWRs were re-fabricated to short length rods, and rod inner pressure gauges and fuel center thermocouples were re-instrumented to the rods. Re-irradiation tests to study the fuel behavior during power change were carried out by means of BOCA/OSF-1 facility at the JMTR. In the tests to study the fission gas release during power change, the rod inner pressure increase was observed during power change, especially during power reduction. The fission gas release during power reduction is estimated to be the release from fission gas bubbles on the grain boundary caused by the thermal stress in the pellet during power reduction. Re-irradiation test of gadolinia added fuel was performed by means of dual re-instrumentation technique (fuel center thermocouples and rod inner pressure gauge). A stepwise fission gas release during power change, and the following fuel center temperature change due to gap conductance change were observed. (author)

  17. Predicting Falls in Parkinson Disease: What Is the Value of Instrumented Testing in OFF Medication State?

    Directory of Open Access Journals (Sweden)

    Martina Hoskovcová

    Full Text Available Falls are a common complication of advancing Parkinson's disease (PD. Although numerous risk factors are known, reliable predictors of future falls are still lacking. The objective of this prospective study was to investigate clinical and instrumented tests of balance and gait in both OFF and ON medication states and to verify their utility in the prediction of future falls in PD patients.Forty-five patients with idiopathic PD were examined in defined OFF and ON medication states within one examination day including PD-specific clinical tests, instrumented Timed Up and Go test (iTUG and computerized dynamic posturography. The same gait and balance tests were performed in 22 control subjects of comparable age and sex. Participants were then followed-up for 6 months using monthly fall diaries and phone calls.During the follow-up period, 27/45 PD patients and 4/22 control subjects fell one or more times. Previous falls, fear of falling, more severe motor impairment in the OFF state, higher PD stage, more pronounced depressive symptoms, higher daily levodopa dose and stride time variability in the OFF state were significant risk factors for future falls in PD patients. Increased stride time variability in the OFF state in combination with faster walking cadence appears to be the most significant predictor of future falls, superior to clinical predictors.Incorporating instrumented gait measures into the baseline assessment battery as well as accounting for both OFF and ON medication states might improve future fall prediction in PD patients. However, instrumented testing in the OFF state is not routinely performed in clinical practice and has not been used in the development of fall prevention programs in PD. New assessment methods for daylong monitoring of gait, balance and falls are thus required to more effectively address the risk of falling in PD patients.

  18. Pilot instrumentation of a Superpave test section at the Kansas Accelerated Testing laboratory

    Science.gov (United States)

    2003-04-01

    Two Superpave test sections were constructed at the Kansas Accelerated Testing Laboratory (K-ATL) with 12.5 mm (2 in) nominal maximum size Superpave mixture (SM-2A) with varying percentages (15 and 30 percent) of river sand. A 150 kN (34 kip) tandem ...

  19. Instrumentation, control and data acquisition system with multiple configurations for test in nuclear environment

    Energy Technology Data Exchange (ETDEWEB)

    Monti, Chiara, E-mail: chiara.monti@enea.it; Neri, Carlo; Pollastrone, Fabio

    2015-10-15

    Highlights: • ENEA developed and characterized a first prototype of the In-Vessel Viewing System (IVVS) probe for ITER. • Piezo motor technology to be used in IVVS probe was tested in neutrons, gamma radiations, high temperature, vacuum and high magnetic fields. • A general architecture of the Data Acquisition and Control System (DACS) was defined and then specialized for each test. • The test campaign has validated instrumentation solutions, which can be effectively used in final IVVS implementation or other ITER diagnostics or applications. - Abstract: The In-Vessel Viewing System is a 3D laser scanning system which will be used to inspect the blanket first wall in ITER. To make the IVVS probe design compatible with the harsh environmental conditions present in ITER, a test campaign was performed in 2012–2013 to verify the adequacy of the main components of the IVVS probe. The IVVS components inspected were an optical encoder, passive components and two customized ultrasonic piezoceramic motors that were instrumented with various sensors. A general architecture of the Data Acquisition and Control System (DACS) was defined and then specialized for each test. To be suitable for this test campaign, the DACS had to host various I/O modules and to properly interface the driver of the customized piezo motors, in order to permit the full control of the test and the acquisition of experimental data. This paper presents the instrumentation solutions designed and implemented for different facilities constraints and the related DACS developed in four specialized versions for the described test campaign.

  20. Modelling of XCO2 Surfaces Based on Flight Tests of TanSat Instruments

    Directory of Open Access Journals (Sweden)

    Li Li Zhang

    2016-11-01

    Full Text Available The TanSat carbon satellite is to be launched at the end of 2016. In order to verify the performance of its instruments, a flight test of TanSat instruments was conducted in Jilin Province in September, 2015. The flight test area covered a total area of about 11,000 km2 and the underlying surface cover included several lakes, forest land, grassland, wetland, farmland, a thermal power plant and numerous cities and villages. We modeled the column-average dry-air mole fraction of atmospheric carbon dioxide (XCO2 surface based on flight test data which measured the near- and short-wave infrared (NIR reflected solar radiation in the absorption bands at around 760 and 1610 nm. However, it is difficult to directly analyze the spatial distribution of XCO2 in the flight area using the limited flight test data and the approximate surface of XCO2, which was obtained by regression modeling, which is not very accurate either. We therefore used the high accuracy surface modeling (HASM platform to fill the gaps where there is no information on XCO2 in the flight test area, which takes the approximate surface of XCO2 as its driving field and the XCO2 observations retrieved from the flight test as its optimum control constraints. High accuracy surfaces of XCO2 were constructed with HASM based on the flight’s observations. The results showed that the mean XCO2 in the flight test area is about 400 ppm and that XCO2 over urban areas is much higher than in other places. Compared with OCO-2’s XCO2, the mean difference is 0.7 ppm and the standard deviation is 0.95 ppm. Therefore, the modelling of the XCO2 surface based on the flight test of the TanSat instruments fell within an expected and acceptable range.

  1. Evaluation report on SCTF Core-III Test S3-22

    International Nuclear Information System (INIS)

    Okubo, Tsutomu; Iguchi, Tadashi; Iwamura, Takamichi; Akimoto, Hajime; Ohnuki, Akira; Abe, Yutaka; Murao, Yoshio; Adachi, Hiromichi.

    1991-07-01

    Two tests (Tests S3-20 and S3-22) were conducted with JAERI's Slab Core Test Facility (SCTF) Core-III in order to investigate water break-through and core cooling behaviors under the intermittent ECC water delivery from the hot legs to one location in the upper plenum and the alternate ECC water delivery to two locations in the upper plenum during reflooding, respectively. This report presents an analysis on Test S3-22 (the alternate case). Subcooled ECC water was injected alternately just above the upper core support plate above Bundles 7 and 8 and Bundles 3 and 4. The total injection rate from both injection ports was the same as that in SCTF Test S3-20 and Test S3-13. Analyzing the test data together with those of Tests S3-13 and S3-20 the following has been found: (1) Alternate break-through occurred immediately corresponding to the alternate ECC water injection except for one period, during which no break-through was observed. However, there observed a difference in break-through behavior that break-through was strong above the low power region, whereas weak above the high power region. (2) Although its break-through behavior was different, nearly the same core cooling as in the continuous or intermittent ECC water delivery case was observed except for the period around quench. (3) Around quench time, degraded core cooling comparing to the continuous or intermittent ECC water delivery case was observed. That is, quench time at the midplane level of the present test was 35 s later than in the continuous case. This is considered to result from decrease in core water inventory caused by water sealing at the cross-over leg. (J.P.N.)

  2. Thermal neutron measurement using the instrumented test bundle and assessment of maximum linear power in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C. S.; Seo, C. K.; Lee, B. C.; Kim, H. N.; Kang, B. W. [KAERI, Taejon (Korea, Republic of)

    2000-10-01

    The HANARO fuel, U{sub 3}Si-Al, has been developed by AECL and tested in NRU reactor. Due to the lack of the data performed under the high power, the repetitive conduct of the irradiation test was required under the power greater than 108kW/m, which is the estimated maximum linear power in the design stage. Accordingly, the instrumented test bundle with SPND(Self Powered Neutron Detector) was fabricated and its irradiation test was performed in IR2 of HANARO. The measured thermal neutron flux with SPND is compared with calculation results by HANAFMS(HANARO Fuel Management System). The difference in the measured and calculated thermal flux values are below {+-}11% and the accuracy of the linear power predicted by HANAFMS is consequently accompanied. Therefore, it is believed that the maximum linear power above 120kW/m is achieved during the irradiation test of the test bundle.

  3. Thermal Testing and Model Correlation for Advanced Topographic Laser Altimeter Instrument (ATLAS)

    Science.gov (United States)

    Patel, Deepak

    2016-01-01

    The Advanced Topographic Laser Altimeter System (ATLAS) part of the Ice Cloud and Land Elevation Satellite 2 (ICESat-2) is an upcoming Earth Science mission focusing on the effects of climate change. The flight instrument passed all environmental testing at GSFC (Goddard Space Flight Center) and is now ready to be shipped to the spacecraft vendor for integration and testing. This topic covers the analysis leading up to the test setup for ATLAS thermal testing as well as model correlation to flight predictions. Test setup analysis section will include areas where ATLAS could not meet flight like conditions and what were the limitations. Model correlation section will walk through changes that had to be made to the thermal model in order to match test results. The correlated model will then be integrated with spacecraft model for on-orbit predictions.

  4. Childhood lead poisoning investigations: evaluating a portable instrument for testing soil lead.

    Science.gov (United States)

    Reames, Ginger; Lance, Larrie L

    2002-04-01

    The Childhood Lead Poisoning Prevention Branch of the California Department of Health Services evaluated a portable X-ray fluorescence (XRF) instrument for use as a soil lead-testing tool during environmental investigations of lead-poisoned children's homes. A Niton XRF was used to test soil at 119 sampling locations in the yards of 11 San Francisco Bay Area houses. Niton XRF readings were highly correlated with laboratory results and met the study criteria for an acceptable screening method. The data suggest that the most health-protective and time-efficient approach to testing for soil lead above regulatory levels is to take either surface readings or readings of a test cup of soil prepared by grinding with a mortar and pestle. The advantage of the test cup method is that the test cup with soil may be submitted to a laboratory for confirmatory analysis.

  5. Standard test method for plutonium assay by plutonium (III) diode array spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method describes the determination of total plutonium as plutonium(III) in nitrate and chloride solutions. The technique is applicable to solutions of plutonium dioxide powders and pellets (Test Methods C 697), nuclear grade mixed oxides (Test Methods C 698), plutonium metal (Test Methods C 758), and plutonium nitrate solutions (Test Methods C 759). Solid samples are dissolved using the appropriate dissolution techniques described in Practice C 1168. The use of this technique for other plutonium-bearing materials has been reported (1-5), but final determination of applicability must be made by the user. The applicable concentration range for plutonium sample solutions is 10–200 g Pu/L. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropria...

  6. Test-particle motion in Einstein's unified field theory. III. Magnetic monopoles and charged particles

    International Nuclear Information System (INIS)

    Johnson, C.R.

    1986-01-01

    In a previous paper (paper I), we developed a method for finding the exact equations of structure and motion of multipole test particles in Einstein's unified field theory: the theory of the nonsymmetric field. In that paper we also applied the method and found in Einstein's unified field theory the equations of structure and motion of neutral pole-dipole test particles possessing no electromagnetic multipole moments. In a second paper (paper II), we applied the method and found in Einstein's unified field theory the exact equations of structure and motion of charged test particles possessing no magnetic monopole moments. In the present paper (paper III), we apply the method and find in Einstein's unified field theory the exact equations of structure and motion of charged test particles possessing magnetic monopole moments. It follows from the form of these equations of structure and motion that in general in Einstein's unified field theory a test particle possessing a magnetic monopole moment in a background electromagnetic field must also possess spin

  7. Chromium(III) release from chromium‐tanned leather elicits allergic contact dermatitis: a use test study

    Science.gov (United States)

    Erfani, Behnaz; Matura, Mihály; Lidén, Carola

    2018-01-01

    Summary Background Chromium (Cr) is a common skin sensitizer. The use of Cr(VI) in leather is restricted in the EU, but that of Cr(III) is not. Objectives To assess whether prolonged exposure to Cr‐tanned leather with mainly Cr(III) release may elicit allergic contact dermatitis in Cr‐allergic individuals. Method Ten Cr‐allergic subjects and 22 controls were patch tested with serial dilutions of Cr(III) and Cr(VI), and with leather samples. They then conducted a use test with a Cr‐tanned and a Cr‐free leather bracelet over a period of 3 weeks, for 12 h per day. Cr deposited on the skin from the bracelets was measured in the controls, and the diphenylcarbazide test for Cr(VI) and extraction tests for Cr(III) and Cr(VI) were conducted for the different leathers. Results Four of 10 Cr‐allergic subjects developed positive reactions to the Cr‐tanned bracelet within 7–21 days, whereas only 1 of 10 had a positive patch test reaction to this leather. Cr released from the Cr‐tanned leather was most probably entirely Cr(III), with a quantifiable amount being deposited on the skin. Conclusions This study strongly suggests that prolonged and repeated exposure to Cr‐tanned leather with mainly Cr(III) release is capable of eliciting allergic contact dermatitis in Cr‐allergic individuals. PMID:29322530

  8. Temperature buffer test. Installation of buffer, heaters and instruments in the deposition hole

    Energy Technology Data Exchange (ETDEWEB)

    Johannesson, Lars-Erik; Sanden, Torbjoern; Aakesson, Mattias [Clay Technology AB, Lund (Sweden); Barcena, Ignacio; Garcia-Sineriz, Jose Luis [Aitemin, Madrid (Spain)

    2010-12-15

    During 2003 the Temperature Buffer Test was installed in Aespoe Hard Rock Laboratory. Temperature, water pressure, relative humidity, total pressure and displacements etc. are measured in numerous points in the test. Most of the cables from the transducers are led in the deposition hole through slots in the rock surface of the deposition hole in watertight tubes to the data collection system in a container placed in the tunnel close to the deposition hole. This report describes the work with the installations of the buffer, heaters, and instruments and yields a description of the final location of all instruments. The report also contains a description of the materials that were installed and the densities yielded after placement.

  9. Temperature buffer test. Installation of buffer, heaters and instruments in the deposition hole

    International Nuclear Information System (INIS)

    Johannesson, Lars-Erik; Sanden, Torbjoern; Aakesson, Mattias; Barcena, Ignacio; Garcia-Sineriz, Jose Luis

    2010-12-01

    During 2003 the Temperature Buffer Test was installed in Aespoe Hard Rock Laboratory. Temperature, water pressure, relative humidity, total pressure and displacements etc. are measured in numerous points in the test. Most of the cables from the transducers are led in the deposition hole through slots in the rock surface of the deposition hole in watertight tubes to the data collection system in a container placed in the tunnel close to the deposition hole. This report describes the work with the installations of the buffer, heaters, and instruments and yields a description of the final location of all instruments. The report also contains a description of the materials that were installed and the densities yielded after placement

  10. Developing and testing an instrument for identifying performance incentives in the Greek health care sector

    Directory of Open Access Journals (Sweden)

    Paleologou Victoria

    2006-09-01

    Full Text Available Abstract Background In the era of cost containment, managers are constantly pursuing increased organizational performance and productivity by aiming at the obvious target, i.e. the workforce. The health care sector, in which production processes are more complicated compared to other industries, is not an exception. In light of recent legislation in Greece in which efficiency improvement and achievement of specific performance targets are identified as undisputable health system goals, the purpose of this study was to develop a reliable and valid instrument for investigating the attitudes of Greek physicians, nurses and administrative personnel towards job-related aspects, and the extent to which these motivate them to improve performance and increase productivity. Methods A methodological exploratory design was employed in three phases: a content development and assessment, which resulted in a 28-item instrument, b pilot testing (N = 74 and c field testing (N = 353. Internal consistency reliability was tested via Cronbach's alpha coefficient and factor analysis was used to identify the underlying constructs. Tests of scaling assumptions, according to the Multitrait-Multimethod Matrix, were used to confirm the hypothesized component structure. Results Four components, referring to intrinsic individual needs and external job-related aspects, were revealed and explain 59.61% of the variability. They were subsequently labeled: job attributes, remuneration, co-workers and achievement. Nine items not meeting item-scale criteria were removed, resulting in a 19-item instrument. Scale reliability ranged from 0.782 to 0.901 and internal item consistency and discriminant validity criteria were satisfied. Conclusion Overall, the instrument appears to be a promising tool for hospital administrations in their attempt to identify job-related factors, which motivate their employees. The psychometric properties were good and warrant administration to a larger

  11. Developing and testing an instrument for identifying performance incentives in the Greek health care sector.

    Science.gov (United States)

    Paleologou, Victoria; Kontodimopoulos, Nick; Stamouli, Aggeliki; Aletras, Vassilis; Niakas, Dimitris

    2006-09-13

    In the era of cost containment, managers are constantly pursuing increased organizational performance and productivity by aiming at the obvious target, i.e. the workforce. The health care sector, in which production processes are more complicated compared to other industries, is not an exception. In light of recent legislation in Greece in which efficiency improvement and achievement of specific performance targets are identified as undisputable health system goals, the purpose of this study was to develop a reliable and valid instrument for investigating the attitudes of Greek physicians, nurses and administrative personnel towards job-related aspects, and the extent to which these motivate them to improve performance and increase productivity. A methodological exploratory design was employed in three phases: a) content development and assessment, which resulted in a 28-item instrument, b) pilot testing (N = 74) and c) field testing (N = 353). Internal consistency reliability was tested via Cronbach's alpha coefficient and factor analysis was used to identify the underlying constructs. Tests of scaling assumptions, according to the Multitrait-Multimethod Matrix, were used to confirm the hypothesized component structure. Four components, referring to intrinsic individual needs and external job-related aspects, were revealed and explain 59.61% of the variability. They were subsequently labeled: job attributes, remuneration, co-workers and achievement. Nine items not meeting item-scale criteria were removed, resulting in a 19-item instrument. Scale reliability ranged from 0.782 to 0.901 and internal item consistency and discriminant validity criteria were satisfied. Overall, the instrument appears to be a promising tool for hospital administrations in their attempt to identify job-related factors, which motivate their employees. The psychometric properties were good and warrant administration to a larger sample of employees in the Greek healthcare system.

  12. MK-III function tests in JOYO. Dump heat exchanger (DHX)

    International Nuclear Information System (INIS)

    Kawahara, Hirotaka; Isozaki, Kazunori; Ishii, Takayuki; Ichige, Satoshi; Sakaba, Hideo; Nakai, Satoru; Nose, Shouiti

    2004-06-01

    A key part of the upgrade of the experimental fast reactor JOYO to the MK-III design was the replacement of the dump heat exchangers. MK-III function tests (SKS-1) of the new dump heat exchangers were carried out from August 27, 2001 through September 13, 2001. The major results of the function tests of the dump heat exchangers were as follows: (1) Air flow of the main blower with an inlet vane opening of 50% was confirmed to exceed the design rated flow of 7,700 m 3 /min. It was also demonstrated that an inlet vane opening of 100% provides about 130% of the design rated flow. This is because the new DHX flow route has more low pressure loss than the design value. (2) Tests of the air flow of the main blower demonstrated that with a fully opened inlet damper, a full opened outlet damper and an inlet vane opening of 0% provides about 5% of the design rated flow. (3) Free flow coast down characteristics of the main blower achieved an inlet vane 0% opening in an average of 7.9 seconds. Revolutions per minute of the main blower reached zero in an average of 8.7 seconds. The delay time from the opening of the vacuum contact breaker to the air flow decrease was approximately 1 second. This was a more conservative value than the 5 seconds assumed in design thermal transient analyses. (4) The loudest noise occurred with the main blower operating with a 25% inlet vane opening. At that time, the noise around the main blower was approximately 100 dB, and in the surrounding monitoring area boundary, the noise was 50 dB. This was confirmed to be within the standard of the Ibaraki prefectural ordinance. (5) Although the MK-III inlet vane and inlet damper drive unit was bigger than the MK-II unit, the accumulator tank was confirmed to provide sufficient volume during a compression air loss event. (author)

  13. The moisture proof connection of signal cables on test rig instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Joung, Chang Young; Ahn, Sung Ho; Hong, Jin Tae; Jeong, Hwang Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-10-15

    The rod inner pressure, centerline temperature, coolant temperature, and neutron flux resulting from the irradiation properties of nuclear fuel are an important factor for evaluating nuclear fuel properties in pile. In addition instrumentation and measurement techniques for nuclear fuel are necessary to measure the exact data. Special sensors such as a TC (thermocouple), LVDT (linear variable differential transformer) and SPND (self-powered neutron detector) are instrumented in and out of the fuel rod to measure the various irradiation characteristics of the nuclear fuel. These sensors are made up of the sensor itself and a signal cable. In the instrumentation, an MI (Mineral Insulated) cable used as the signal cable has such properties as high electrical insulation, heat resistance, and mechanical strength. However, it is difficult to handle and treat with care owing to the extremely hard composition, which is made up of weak signal wires and alumina powder in a stainless tube. The sealing of the end tip of the MI cable and extension cable is very important in terms of the insulation resistance to seal the insulator inside the MI cable tube from moisture. To maintain the insulation of sensors and signal cables, the insulation resistance must be checked in accordance with each process throughout the instrumentation and fabrication period. To safely mount the signal cables drawn from a fuel test rig on the terminal block of a junction panel, the MI and extension cables should be easy to connect. Therefore, it is necessary to develop instrumentation technologies of a moisture proof connection process for a fuel test rig. This paper will provide an overview of the work done with moisture proof connection procedures to connect the MI and extension cables to extend the MI cables jointed with the sensor.

  14. A multi-functional testing instrument for heat assisted magnetic recording media

    International Nuclear Information System (INIS)

    Yang, H. Z.; Chen, Y. J.; Leong, S. H.; An, C. W.; Ye, K. D.; Hu, J. F.; Yin, M. J.

    2014-01-01

    With recent developments in heat assisted magnetic recording (HAMR), characterization of HAMR media is becoming very important. We present a multi-functional instrument for testing HAMR media, which integrates HAMR writing, reading, and a micro-magneto-optic Kerr effect (μ-MOKE) testing function. A potential application of the present instrument is to make temperature dependent magnetic property measurement using a pump-probe configuration. In the measurement, the media is heated up by a heating (intense) beam while a testing (weak) beam is overlapped with the heating beam for MOKE measurement. By heating the media with different heating beam power, magnetic measurements by MOKE at different temperatures can be performed. Compared to traditional existing tools such as the vibrating sample magnetometer, the present instrument provides localized and efficient heating at the measurement spot. The integration of HAMR writing and μ-MOKE system can also facilitate a localized full investigation of the magnetic media by potential correlation of HAMR head independent write/read performance to localized magnetic properties

  15. Field instrumentation and testing needs for a high level waste repository

    International Nuclear Information System (INIS)

    Marti, J.; Maini, T.

    1981-03-01

    A review has been conducted of the testing and measurement needs posed by a deep geologic High Level Waste (HLW) repository in crystalline or argillaceous rocks. Siting, design, construction, operation and decommissioning of the repository have been covered, together with the planning of a Test and Demonstration Facility. Instruments and methods available have been critically assessed in their ability to fulfil the aforementioned testing and monitoring programmes. Special attention has been paid to the relation of measurements to the data needs and to the tests likely to generate such data. This assessment has concentrated on measurements of absolute rock stresses, monitoring of changes in rock stress, evaluation of the rock mass deformability, measurement of relative displacements and determination of the hydrogeologic parameters of the rock mass. Other measurements have been studied with a lesser degree of attention. The overall conclusion is that, from the instrumentation and testing points of view, present plans for a test and demonstration facility in the early nineties and a repository soon after 2000 are indeed feasible. Specific conclusions on the state-of-the-art and development needs are presented in the report. (author)

  16. Post-test analysis of ROSA-III experiment RUNs 705 and 706

    International Nuclear Information System (INIS)

    Koizumi, Yasuo; Soda, Kunihisa; Kikuchi, Osamu; Tasaka, Kanji; Shiba, Masayoshi

    1980-07-01

    The purpose of ROSA-III experiment with a scaled BWR Test facility is to examine primary coolant thermal-hydraulic behavior and performance of ECCS during a postulated loss-of-coolant accident of BWR. The results provide the information for verification and improvement of reactor safety analysis codes. RUNs 705 and 706 assumed a 200% double-ended break at the recirculation pump suction. RUN 705 was an isothermal blowdown test without initial power and initial core flow. In RUN 706 for an average core power and no ECCS, the main steam line and feed water line were isolated immediately on the break. Post-test analysis of RUNs 705 and 706 was made with computer code RELAP4J. The agreement in system pressure between calculation and experiment was satisfactory. However, the calculated heater rod surface temperature were significantly higher than the experimental ones. The calculated axial temperature profile was different in tendency from the experimental one. The calculated mixture level behavior in the core was different from the liquid void distribution observed in experiment. The rapid rise of fuel rod surface temperature was caused by the reduction of heat transfer coefficient attributed to the increase of quality. The need was indicated for improvement of analytical model of void distribution in the core, and also to performe a characteristic test of recirculation line under reverse flow and to examine the core inlet flow rate experimentally and analytically. (author)

  17. Evaluation report on SCTF Core-III test S3-06

    International Nuclear Information System (INIS)

    Iwamura, Takamichi; Iguchi, Tadashi; Akimoto, Hajime; Okubo, Tsutomu; Ohnuki, Akira; Adachi, Hiromichi; Murao, Yoshio; Minato, Akihiko; Sakaki, Isao.

    1988-10-01

    In order to investigate the effect of radial power distribution on the thermal-hydraulic characteristics during the reflood phase of a PWR-LOCA with a combined injection type ECCS, a core cooling separate effect test S3-06 and a combined injection test S3-16-Phase 2 were performed using the Slab Core Test Facility (SCTF) Core-III. The radial power distributions in these two tests simulated a reference distribution for a PWR with a combined injection type ECCS and a steep distribution for a PWR with a cold leg injection type ECCS, respectively. Under the radial power distribution of a PWR with a combined injection type ECCS, the radial power distribution had little effect on the thermal-hydraulic behavior in the two-phase up-flow region due to the approximately flat power distribution in this region (power ratio = 1.04 ∼ 1.08). The overall fluid behavior in the pressure vessel was also little affected by the radial power distribution. On the other hand, under the steep radial power distribution (peak power ratio = 1.36), the degree of heat transfer enhancement in high power bundles in the two-phase up-flow region was dominated by the bundlewise radial power ratio as in the case of a PWR with a cold leg injection type ECCS. (author)

  18. UPTF test instrumentation. Measurement system identification, engineering units and computed parameters

    International Nuclear Information System (INIS)

    Sarkar, J.; Liebert, J.; Laeufer, R.

    1992-11-01

    This updated version of the previous report /1/ contains, besides additional instrumentation needed for 2D/3D Programme, the supplementary instrumentation in the inlet plenum of SG simulator and hot and cold leg of broken loop, the cold leg of intact loops and the upper plenum to meet the requirements (Test Phase A) of the UPTF Programme, TRAM, sponsored by the Federal Minister of Research and Technology (BMFT) of the Federal Republic of Germany. For understanding, the derivation and the description of the identification codes for the entire conventional and advanced measurement systems classifying the function, and the equipment unit, key, as adopted in the conventional power plants, have been included. Amendments have also been made to the appendices. In particular, the list of measurement systems covering the measurement identification code, instrument, measured quantity, measuring range, band width, uncertainty and sensor location has been updated and extended to include the supplementary instrumentation. Beyond these amendments, the uncertainties of measurements have been precisely specified. The measurement identification codes which also stand for the identification of the corresponding measured quantities in engineering units and the identification codes derived therefrom for the computed parameters have been adequately detailed. (orig.)

  19. JOYO MK-III performance test. Criticality test, excess reactivity measurement and burn-up coefficient measurement

    International Nuclear Information System (INIS)

    Maeda, Shigetaka; Sekine, Takashi; Kitano, Akihiro; Nagasaki, Hideaki

    2005-03-01

    The MK-III performance test began in June 2003 to fully characterize the upgraded core and heat transfer system of the experimental fast reactor JOYO. This paper describes the results of the approach to criticality, the excess reactivity evaluation and the burn-up coefficient measurement. In the approach to criticality test, the MK-III core achieved initial criticality at the control rod bank position of 412.8 mm on 14:03 July 2nd, 2003. Because the replacement of the outer two rows of reflector subassemblies with shielding subassemblies reduced the source range monitor signals by a factor of 3 at the same reactor power compared with those in the MK-II core, we measured the change of the monitor's response and determined the count rate 2x10 4 cps.' as an appropriate value judging the zero power criticality. In the excess reactivity evaluation, the zero power excess reactivity at 250degC was 2.99±0.10%Δk/kk' based on the measured critical rod bank position and the measured control rod worths. The predicted value by the JOYO core management code system HESTIA was 3.13±0.16%Δk/kk', showing good agreement with the measured value. The measured excess reactivity was within the safety requirement limit. In the burn-up coefficient measurement, the excess reactivity change versus the reactor burn-up was evaluated. The measurement method adopted was to measure the control rod positions during the rated power operation. A value of -2.12x10 -4 Δk/kk'/MWd was obtained as a measured burn-up coefficient. The value calculated by HESTIA was -2.12x10 -4 Δk/kk'/MWd, and it agreed well with the measured value. All technical safety requirements for MK-III core were satisfied and the calculation accuracy of the core management code system HESTIA was confirmed. (author)

  20. Development of Mechanical Sealing and Laser Welding Technology to Instrument Thermocouple for Nuclear Fuel Test Rod

    International Nuclear Information System (INIS)

    Joung, Chang-Young; Ahn, Sung-Ho; Hong, Jin-Tae; Kim, Ka-Hye; Huh, Sung-Ho

    2015-01-01

    Zircaloy-4 of the nuclear fuel test rod, AISI 316L of the mechanical sealing parts, and the MI (mineral insulated) cable at a thermocouple instrumentation are hetero-metals, and are difficult to weld to dissimilar materials. Therefore, a mechanical sealing method to instrument the thermocouple should be conducted using two kinds of sealing process as follows: One is a mechanical sealing process using Swagelok, which is composed of sealing components that consists of an end-cap, a seal tube, a compression ring and a Swagelok nut. The other is a laser welding process used to join a seal tube, and an MI cable, which are made of the same material. The mechanical sealing process should be sealed up with the mechanical contact compressed by the strength forced between a seal tube and an end-cap, and the laser welding process should be conducted to have no defects on the sealing area between a seal tube and an MI cable. Therefore, the mechanical sealing and laser welding techniques need to be developed to accurately measure the centerline temperature of the nuclear fuel test rod in an experimental reactor. The mechanical sealing and laser welding tests were conducted to develop the thermocouple instrumentation techniques for the nuclear fuel test rod. The optimum torque value of a Swagelok nut to seal the mechanical sealing part between the end-cap and seal tube was established through various torque tests using a torque wrench. The optimum laser welding conditions to seal the welding part between a seal tube and an MI cable were obtained through various welding tests using a laser welding system

  1. Development of Mechanical Sealing and Laser Welding Technology to Instrument Thermocouple for Nuclear Fuel Test Rod

    Energy Technology Data Exchange (ETDEWEB)

    Joung, Chang-Young; Ahn, Sung-Ho; Hong, Jin-Tae; Kim, Ka-Hye; Huh, Sung-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    Zircaloy-4 of the nuclear fuel test rod, AISI 316L of the mechanical sealing parts, and the MI (mineral insulated) cable at a thermocouple instrumentation are hetero-metals, and are difficult to weld to dissimilar materials. Therefore, a mechanical sealing method to instrument the thermocouple should be conducted using two kinds of sealing process as follows: One is a mechanical sealing process using Swagelok, which is composed of sealing components that consists of an end-cap, a seal tube, a compression ring and a Swagelok nut. The other is a laser welding process used to join a seal tube, and an MI cable, which are made of the same material. The mechanical sealing process should be sealed up with the mechanical contact compressed by the strength forced between a seal tube and an end-cap, and the laser welding process should be conducted to have no defects on the sealing area between a seal tube and an MI cable. Therefore, the mechanical sealing and laser welding techniques need to be developed to accurately measure the centerline temperature of the nuclear fuel test rod in an experimental reactor. The mechanical sealing and laser welding tests were conducted to develop the thermocouple instrumentation techniques for the nuclear fuel test rod. The optimum torque value of a Swagelok nut to seal the mechanical sealing part between the end-cap and seal tube was established through various torque tests using a torque wrench. The optimum laser welding conditions to seal the welding part between a seal tube and an MI cable were obtained through various welding tests using a laser welding system.

  2. Development of Ozone Detector for Ksr-Iii and Preliminary Test Results

    Directory of Open Access Journals (Sweden)

    Seung-Hyun Hwang

    2000-12-01

    Full Text Available KARI (Korea Aerospace Research Institute has measured the ozone density profiles over the Korean Peninsular since the launch of the Korean Sounding Rocket-I (KSR-I in 1993. The purpose of ozone measurements is to obtain the stratospheric and mesospheric vertical ozone density profiles over the Korean Peninsular with solar UV radiometers. With the visible channel of the radiometer, the attitude variation of the rocket was corrected and compensated. Developed system is based on ozone detector designs onboard the KSR-I and KSR-II. We discuss the development of ozone detector which will be onboard the KSR-III and its circuit and vibration test results for EM Model.

  3. Testing the Q-DIO as an instrument to measure the documented quality of nursing diagnoses, interventions, and outcomes.

    NARCIS (Netherlands)

    Muller-Staub, M.; Lunney, M.; Lavin, M.A.; Needham, I.; Odenbreit, M.; Achterberg, T. van

    2008-01-01

    PURPOSE: To describe pilot testing of Quality of Diagnoses, Interventions and Outcomes (Q-DIO), an instrument to measure quality of nursing documentation. DESIGN: Instrument testing was performed using a random, stratified sample of 60 nursing documentations representing hospital nursing with and

  4. Testing instrument validity for LATE identification based on inequality moment constraints

    DEFF Research Database (Denmark)

    Huber, Martin; Mellace, Giovanni

    2015-01-01

    We derive testable implications of instrument validity in just identified treatment effect models with endogeneity and consider several tests. The identifying assumptions of the local average treatment effect allow us to both point identify and bound the mean potential outcomes (i) of the always...... takers under treatment and (ii) of the never takers under non-treatment. The point identified means must lie within their respective bounds, which provides us with four testable inequality moment constraints. Finally, we adapt our testing framework to the identification of distributional features....... A brief simulation study and an application to labor market data are also provided....

  5. Status Report on Efforts to Enhance Instrumentation to Support Advanced Test Reactor Irradiations

    Energy Technology Data Exchange (ETDEWEB)

    J. Rempe; D. Knudson; J. Daw; T. Unruh; B. Chase; R. Schley; J. Palmer; K. Condie

    2014-01-01

    The Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF) in April 2007 to support the growth of nuclear science and technology in the United States (US). By attracting new research users - universities, laboratories, and industry - the ATR NSUF facilitates basic and applied nuclear research and development, further advancing the nation's energy security needs. A key component of the ATR NSUF effort at the Idaho National Laboratory (INL) is to design, develop, and deploy new in-pile instrumentation techniques that are capable of providing real-time measurements of key parameters during irradiation. To address this need, an assessment of instrumentation available and under-development at other test reactors was completed. Based on this initial review, recommendations were made with respect to what instrumentation is needed at the ATR, and a strategy was developed for obtaining these sensors. In 2009, a report was issued documenting this program’s strategy and initial progress toward accomplishing program objectives. Since 2009, annual reports have been issued to provide updates on the program strategy and the progress made on implementing the strategy. This report provides an update reflecting progress as of January 2014.

  6. Development of diagnostic test instruments to reveal level student conception in kinematic and dynamics

    Science.gov (United States)

    Handhika, J.; Cari, C.; Suparmi, A.; Sunarno, W.; Purwandari, P.

    2018-03-01

    The purpose of this research was to develop a diagnostic test instrument to reveal students' conceptions in kinematics and dynamics. The diagnostic test was developed based on the content indicator the concept of (1) displacement and distance, (2) instantaneous and average velocity, (3) zero and constant acceleration, (4) gravitational acceleration (5) Newton's first Law, (6) and Newton's third Law. The diagnostic test development model includes: Diagnostic test requirement analysis, formulating test-making objectives, developing tests, checking the validity of the content and the performance of reliability, and application of tests. The Content Validation Index (CVI) results in the category are highly relevant, with a value of 0.85. Three questions get negative Content Validation Ratio CVR) (-0.6), after revised distractors and clarify visual presentation; the CVR become 1 (highly relevant). This test was applied, obtained 16 valid test items, with Cronbach Alpha value of 0.80. It can conclude that diagnostic test can be used to reveal the level of students conception in kinematics and dynamics.

  7. Proof-testing strategies induced by dangerous detected failures of safety-instrumented systems

    International Nuclear Information System (INIS)

    Liu, Yiliu; Rausand, Marvin

    2016-01-01

    Some dangerous failures of safety-instrumented systems (SISs) are detected almost immediately by diagnostic self-testing as dangerous detected (DD) failures, whereas other dangerous failures can only be detected by proof-testing, and are therefore called dangerous undetected (DU) failures. Some items may have a DU- and a DD-failure at the same time. After the repair of a DD-failure is completed, the maintenance team has two options: to perform an insert proof test for DU-failure or not. If an insert proof test is performed, it is necessary to decide whether the next scheduled proof test should be postponed or performed at the scheduled time. This paper analyzes the effects of different testing strategies on the safety performance of a single channel of a SIS. The safety performance is analyzed by Petri nets and by approximation formulas and the results obtained by the two approaches are compared. It is shown that insert testing improves the safety performance of the channel, but the feasibility and cost of the strategy may be a hindrance to recommend insert testing. - Highlights: • Identify the tests induced by detected failures. • Model the testing strategies following DD-failures. • Propose analytical formulas for effects of strategies. • Simulate and verify the proposed models.

  8. Test-retest reliability and practice effects of the Wechsler Memory Scale-III.

    Science.gov (United States)

    Lo, Ada H Y; Humphreys, Michael; Byrne, Gerard J; Pachana, Nancy A

    2012-09-01

    Although serial administration of cognitive tests is increasingly common, there is a paucity of research on test-retest reliabilities and practice effects, both of which are important for evaluating changes in functioning. Reliability is generally conceptualized as involving short-lasting changes in performance. However, when repeated testing occurs over a period of years, there will be some longer lasting effects. The implications of these longer lasting effects and practice effects on reliability were examined in the context of repeated administrations of the Wechsler Memory Scale-III in 339 community-dwelling women aged 40-79 years over 2 to 7 years. The results showed that Logical Memory and Verbal Paired Associates subtests were consistently the most reliable subtests across the age cohorts. The magnitude of practice effects varied as a function of subtests and age. The largest practice effects were found in the youngest age cohort, especially on the Faces, Logical Memory, and Verbal Paired Associates subtests. ©2012 The British Psychological Society.

  9. Ares I Scale Model Acoustic Test Instrumentation for Acoustic and Pressure Measurements

    Science.gov (United States)

    Vargas, Magda B.; Counter, Douglas

    2011-01-01

    Ares I Scale Model Acoustic Test (ASMAT) is a 5% scale model test of the Ares I vehicle, launch pad and support structures conducted at MSFC to verify acoustic and ignition environments and evaluate water suppression systems Test design considerations 5% measurements must be scaled to full scale requiring high frequency measurements Users had different frequencies of interest Acoustics: 200 - 2,000 Hz full scale equals 4,000 - 40,000 Hz model scale Ignition Transient: 0 - 100 Hz full scale equals 0 - 2,000 Hz model scale Environment exposure Weather exposure: heat, humidity, thunderstorms, rain, cold and snow Test environments: Plume impingement heat and pressure, and water deluge impingement Several types of sensors were used to measure the environments Different instrument mounts were used according to the location and exposure to the environment This presentation addresses the observed effects of the selected sensors and mount design on the acoustic and pressure measurements

  10. Low velocity instrumented impact testing of four new damage tolerant carbon/epoxy composite systems

    Science.gov (United States)

    Lance, D. G.; Nettles, A. T.

    1990-01-01

    Low velocity drop weight instrumented impact testing was utilized to examine the damage resistance of four recently developed carbon fiber/epoxy resin systems. A fifth material, T300/934, for which a large data base exists, was also tested for comparison purposes. A 16-ply quasi-isotropic lay-up configuration was used for all the specimens. Force/absorbed energy-time plots were generated for each impact test. The specimens were cross-sectionally analyzed to record the damage corresponding to each impact energy level. Maximum force of impact versus impact energy plots were constructed to compare the various systems for impact damage resistance. Results show that the four new damage tolerant fiber/resin systems far outclassed the T300/934 material. The most damage tolerant material tested was the IM7/1962 fiber/resin system.

  11. Psychometric testing of an instrument to measure the experience of home.

    Science.gov (United States)

    Molony, Sheila L; McDonald, Deborah Dillon; Palmisano-Mills, Christine

    2007-10-01

    Research related to quality of life in long-term care has been hampered by a paucity of measurement tools sensitive to environmental interventions. The primary aim of this study was to test the psychometric properties of a new instrument, the Experience of Home (EOH) Scale, designed to measure the strength of the experience of meaningful person-environment transaction. The instrument was administered to 200 older adults in diverse dwelling types. Principal components analysis provided support for construct validity, eliciting a three-factor solution accounting for 63.18% of variance in scores. Internal consistency reliability was supported with Cronbach's alpha of .96 for the entire scale. The EOH Scale is a unique research tool to evaluate interventions to improve quality of living in residential environments.

  12. Instrumentation, Field Network And Process Automation for the LHC Cryogenic Line Tests

    CERN Document Server

    Bager, T; Bertrand, G; Casas-Cubillos, J; Gomes, P; Parente, C; Riddone, G; Suraci, A

    2000-01-01

    This paper describes the cryogenic control system and associated instrumentation of the test facility for 3 pre-series units of the LHC Cryogenic Distribution Line. For each unit, the process automation is based on a Programmable Logic Con-troller implementing more than 30 closed control loops and handling alarms, in-terlocks and overall process management. More than 160 sensors and actuators are distributed over 150 m on a Profibus DP/PA network. Parameterization, cali-bration and diagnosis are remotely available through the bus. Considering the diversity, amount and geographical distribution of the instru-mentation involved, this is a representative approach to the cryogenic control system for CERN's next accelerator.

  13. Development and Testing of UCLA's Electron Losses and Fields Investigation (ELFIN) Instrument Payload

    Science.gov (United States)

    Wilkins, C.; Bingley, L.; Angelopoulos, V.; Caron, R.; Cruce, P. R.; Chung, M.; Rowe, K.; Runov, A.; Liu, J.; Tsai, E.

    2017-12-01

    UCLA's Electron Losses and Fields Investigation (ELFIN) is a 3U+ CubeSat mission designed to study relativistic particle precipitation in Earth's polar regions from Low Earth Orbit. Upon its 2018 launch, ELFIN will aim to address an important open question in Space Physics: Are Electromagnetic Ion-Cyclotron (EMIC) waves the dominant source of pitch-angle scattering of high-energy radiation belt charged particles into Earth's atmosphere during storms and substorms? Previous studies have indicated these scattering events occur frequently during storms and substorms, and ELFIN will be the first mission to study this process in-situ.Paramount to ELFIN's success is its instrument suite consisting of an Energetic Particle Detector (EPD) and a Fluxgate Magnetometer (FGM). The EPD is comprised of two collimated solid-state detector stacks which will measure the incident flux of energetic electrons from 50 keV to 4 MeV and ions from 50 keV to 300 keV. The FGM is a 3-axis magnetic field sensor which will capture the local magnetic field and its variations at frequencies up to 5 Hz. The ELFIN spacecraft spins perpendicular to the geomagnetic field to provide 16 pitch-angle particle data sectors per revolution. Together these factors provide the capability to address the nature of radiation belt particle precipitation by pitch-angle scattering during storms and substorms.ELFIN's instrument development has progressed into the late Engineering Model (EM) phase and will soon enter Flight Model (FM) development. The instrument suite is currently being tested and calibrated at UCLA using a variety of methods including the use of radioactive sources and applied magnetics to simulate orbit conditions during spin sectoring. We present the methods and test results from instrument calibration and performance validation.

  14. In-pile instrumentation improvements for fuel irradiations in test reactor

    International Nuclear Information System (INIS)

    Blanc, J.Y.; Bernard, J.L.; Estrade, J.; Geoffroy, G.

    1996-01-01

    Knowledge of fuel limits and safety margins in normal and off-normal transients in nuclear power plants remains a constant preoccupation for electricity producers and fuel manufacturers. Accurate determination of such limits, through fuel irradiation testing in the OSIRIS reactor at Saclay is closely linked to the reliability of appropriate instrumentation techniques. Two paths are currently followed to obtain short experimental rods: segmented fuel coming directly from power plants, or re-fabrication of rods in hot cells with our FABRICE process. It can be associated with instrumentation such as fuel centerline thermocouple in annular pellets, pressure transducer or fission gas release measurement by gamma-spectrometry using helium sweeping, in analytic experiments. Our present development, to be implemented in 1993, is the the centerline instrumentation of a fuel column with solid pellets. Inserting the thermocouple requires a cold drilling machine, using CO 2 freezing of broken UO 2 (with liquid nitrogen). During the fuel rod irradiation itself, we try to lower the uncertainties associated to power determination, using thermal balance or neutronic calibration, or even gamma spectrometry. A description of the new test train designed for the ISABELLE water loop in OSIRIS is given, with special emphasis on instrumentation: a LVDT for measuring fuel rod elongation and eventual clad failure, and increased number and better localization of thermocouples and SPDN. The third part is devoted to the measurements by optical microdensitometry of neutron radiographs of the fuel pellet dish modification after irradiation. Dishes are generally disappearing through thermal and mechanical deformation of the pellet, and this can eventually be modelized to better understand pellet-cladding mechanical interaction. (author). 3 refs, 5 figs

  15. OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. III. MEASURES BELOW THE DIFFRACTION LIMIT OF THE WIYN TELESCOPE

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Van Altena, William F.; Howell, Steve B.; Sherry, William H.; Ciardi, David R.

    2011-01-01

    In this paper, we study the ability of CCD- and electron-multiplying-CCD-based speckle imaging to obtain reliable astrometry and photometry of binary stars below the diffraction limit of the WIYN 3.5 m Telescope. We present a total of 120 measures of binary stars, 75 of which are below the diffraction limit. The measures are divided into two groups that have different measurement accuracy and precision. The first group is composed of standard speckle observations, that is, a sequence of speckle images taken in a single filter, while the second group consists of paired observations where the two observations are taken on the same observing run and in different filters. The more recent paired observations were taken simultaneously with the Differential Speckle Survey Instrument, which is a two-channel speckle imaging system. In comparing our results to the ephemeris positions of binaries with known orbits, we find that paired observations provide the opportunity to identify cases of systematic error in separation below the diffraction limit and after removing these from consideration, we obtain a linear measurement uncertainty of 3-4 mas. However, if observations are unpaired or if two observations taken in the same filter are paired, it becomes harder to identify cases of systematic error, presumably because the largest source of this error is residual atmospheric dispersion, which is color dependent. When observations are unpaired, we find that it is unwise to report separations below approximately 20 mas, as these are most susceptible to this effect. Using the final results obtained, we are able to update two older orbits in the literature and present preliminary orbits for three systems that were discovered by Hipparcos.

  16. Development of an End-plug Welding Technology for an Instrumented Fuel Irradiation Test

    International Nuclear Information System (INIS)

    Kim, Soo Sung; Lee, Chul Yong; Shin, Yoon Taek; Choo, Kee Nam

    2010-01-01

    The irradiation test of end-plug specimens was planned for the evaluation of nuclear fuels performance. To establish the fabrication process, and for satisfying the requirements of the irradiation test, an orbital-GTA weld machine for the specimens of the dual rods was developed, and the preliminary welding experiments for optimizing the process conditions of the specimens of the dual rods were performed. Dual rods with a 9.5mm diameter and a 0.6mm wall thickness of the cladding tubes and end-plugs have been used and the optimum conditions of the pin-hole welding have also been selected. This paper describes the experimental results of the GTA welds of the specimens of the dual rods and the metallography examinations of the GTA welded specimens for various welding conditions for the instrumented fuel irradiation test. These investigations satisfied the requirements of the instrumented irradiation test and the GTA welds for the specimens of the dual rods at the HANARO research reactor

  17. ASK Procedure for Instrumented Pre-cracked Charpy-Type Tests

    International Nuclear Information System (INIS)

    Varga, T.; Njo, D.H.; Prantl, G.

    1981-01-01

    The essential technical content of the ASK procedure originated from development work in Switzerland since 1963, and practical experiences gained since 1972. The remainder of the content and the format of the procedure are based on the ASTM E 24.03.03. (Tentative Draft Copy) 'Proposed Method for Pre-cracked Charpy Impact and Slow-Bend Testing of Metallic Materials' by C. E. Harbower, 1973. Two different velocities, 5 m/s and 0.1 m/s were used with a Schnadt-type machine of rigid construction. The stiffness of the machine proved to be very suitable for instrumented testing. The instrumented Schnadt-Type machine was equipped with strain gauges both on the top of the pendulum and on the chisel. A static force calibration was followed by energy calibration, comparing potential energy losses with the area under the force-deflection curve. Deflection was measured using a high frequency eddy current method on the pendulum, and for slow testing by means of an inductive gauge on the chisel. Charpy-Type specimens of 1.0 mm max notch depth and 0.12 mm max notch radius were pre-cracked using a resonant fatigue testing machine, or an eccentric drive machine. Crack propagation rate da/dN was measured using 'Russenberger' measuring gauges. In addition a new technique for the detection of dynamic crack initiation, developed at the Institute of Research and Technology (TVFA) in Vienna is discussed and some results presented

  18. Structural analysis on the open basket type instrumented capsule for fuel irradiation tests in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Do Sik; Kang, Y. H.; Kim, B. G.; Cho, M. S.; Sohn, J. M.; Choo, K. N.; Oh, J. M.; Shin, Y. T.; Park, S. J. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-05-01

    To develop the open basket type instrumented capsule to be used for the irradiation test of various nuclear fuels, it is necessary to ensure the compatibility of the capsule with HANARO and the structural integrity of the capsule. The dimensions of the open basket type instrumented capsule were determined in the basis of the pressure drop criteria in OR test hole of HANARO(mass flow rate <12.7kg/s, pressure drop {delta}P>200kPa). From the buckling stability analysis for this capsule, the critical buckling load P{sub cr} was 7.5kN. The vertical impact stress of the capsule under unit impact load was evaluated by the transient analysis, and the maximum vertical impact load calculated from the impact stress and the allowable stress was 60.5kN. Under the loading of the calculated Pcr, the maximum vertical impact stress was 20.4MPa. The structural integrity of the capsule under a horizontal impact loading was also examined. The mechanical stresses occurred by the pressure difference at the inner and outer surface of cladding and by the coolant pressure at the surface of cladding were 3.1MPa and 43.3MPa, respectively. These stress values were lower than the allowable stress in each case. Therefore, it was ensured that the instrumented capsule for the irradiation test of various nuclear fuels met the criteria on the structural integrity during installing and testing the capsule in HANARO. 8 refs., 61 figs., 3 tabs. (Author)

  19. PC-based analog signal generator for simulated detector signals and arbitrary test waveforms for testing the nuclear instruments

    International Nuclear Information System (INIS)

    Catanescu, V.

    1999-01-01

    This work is performed in cooperation with IAEA-Vienna as a project, proposed as part of Agency's C o-ordinated Research Programme of Development of Computer-based Troubleshooting Tools and Instruments. A convenient way for testing and calibrating modern scientific equipment is to connect the test instruments to a personal computer to get additional feasibilities. This way, all settings for test, measurement and data acquisition functions are done by means of PC and are controlled by software drivers. This multifunctional spectrometric pulse generator is able to characterize different parts of high-resolution nuclear spectroscopy chain (preamplifier, amplifier, analog to digital converter, multichannel analyzer) as well as the whole chain. For this it generates periodic or random pulses with shape, time and amplitude specifications controlled by PC. Characteristics such as integral linearity, differential linearity, dead time, rate channel shifting and others will be easily determined. The block diagram of the multifunctional spectrometric generator is shown. The main sections are: PC-interface, control registers and command generation; PC-controlled periodic and random logic pulse oscillators; PC-controlled delay and width of periodic or random logic pulses; constant and ultra-linear ramp references for spectrometric pulse generation; generation of the tail and flat top pulses with PC-controlled amplitude and decay time; semi-gaussian pulse generation, polarity inverter and output amplifier. The specifications for generated signal correspond to: shape, time specifications and amplitude size. (author)

  20. Irradiation test plan of instrumented capsule(05F-01K) for nuclear fuel irradiation in Hanaro (Revision 1)

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Jae Min; Kim, B. G.; Choi, M. H. (and others)

    2006-09-15

    An instrumented capsule was developed to be able to measure fuel characteristics, such as fuel temperature, internal pressure of fuel rod, fuel pellet elongation, and neutron flux, etc., during the irradiation test of nuclear fuel in HANARO. The instrumented capsule for measuring and monitoring fuel centerline temperature and neutron flux was designed and manufactured. And then, to verify the design of the instrumented capsule in the test hole, it was successfully irradiated in the test hole of HANARO from March 14, 2003 to June 1, 2003 (53.84 full power days at 24 MW). In the year of 2004, 3 test fuel rods and the 03F-05K instrumented fuel capsule were designed and fabricated to measure fuel centerline temperature, internal pressure of fuel rod, and fuel axial deformation during irradiation test. Now, this capsule was successfully irradiated in the test hole OR5 of HANARO reactor from April 27, 2004 to October 1, 2004 (59.5 full power days at 24-30 MW). The capsule and fuel rods have been be dismantled and fuel rods have been examined at the hot cell of IMEF. The instrumented fuel capsule (05F-01K) was designed and manufactured for a design verification test of the dual instrumented fuel rods. The irradiation test of the 05F-01K instrumented fuel capsule will be carried out at the OR5 vertical experimental hole of HANARO.

  1. A PC-based Flexible Solution for Virtual Instrumentation of a Multi-Purpose Test Bed

    Directory of Open Access Journals (Sweden)

    Benatzky Christian

    2006-11-01

    Full Text Available The aim of the paper is to give an overview of a test bed set up for lightweight flexible structures. The purpose of the test bed is to compare different concepts for suppressing structural vibrations. It is demonstrated that such a complex measurement and actuation task can be easily implemented on a single PC using standard software like Matlab/SIMULINK® with a minimum of custom hardware. With the help of this PC standard engineering tasks like measuring, identification of transfer functions, as well as controller design and implementation in soft real-time can be carried out easily (rapid prototyping. The resulting system is flexible and scalable, enabling an engineer to perform all the above mentioned tasks for a given test object within minimum time. Additionally, the utilization of Matlab/SIMULINK® facilitates the realization of a versatile virtual instrumentation system which is easy to use and may also be remote-controlled.

  2. Vibration test report for in-chimney bracket and instrumented fuel assembly

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Yoon, D. B.; Cho, Y. G.; Ahn, G. H.; Lee, J. H.; Park, J.H

    2000-10-01

    The vibration levels of in-chimney bracket structure which is installed in reactor chimney and instrumented fuel assembly(Type-B Bundle) are investigated under the steady state normal operating condition of the reactor. For this purpose, 4 acceleration data on the guide tube of the instrumented fuel assembly and in-chimney bracket structures subjected to fluid induced vibration are measured. For the analysis of the vibration data, vibration analysis program which can perform basic time and frequency domain analysis, is prepared, and its reliability is verified by comparing the analysis results with those of commercial analysis program(I-DEAS). In time domain analysis, maximum amplitudes, and RMS values of accelerations and displacements from the measured vibration signal, are obtained. The frequency components of the vibration data are analyzed by using the frequency domain analysis. These analysis results show that the levels of the measured vibrations are within the allowable level, and the low frequency component near 10 Hz is dominant in the vibration signal. For the evaluation of the structural integrity on the in-chimney bracket and related structures including the instrumented fuel assembly, the static analysis for ANSYS finite element model is carried out. These analysis results show that the maximum stresses are within the allowable stresses of the ASME code, and the maximum displacement of the top of the flow tube is within the displacement limit. Therefore any damage on the structural integrity is not expected when the irradiation test is performed using the in-chimney bracket.

  3. Vibration test report for in-chimney bracket and instrumented fuel assembly

    International Nuclear Information System (INIS)

    Ryu, Jeong Soo; Yoon, D. B.; Cho, Y. G.; Ahn, G. H.; Lee, J. H.; Park, J.H.

    2000-10-01

    The vibration levels of in-chimney bracket structure which is installed in reactor chimney and instrumented fuel assembly(Type-B Bundle) are investigated under the steady state normal operating condition of the reactor. For this purpose, 4 acceleration data on the guide tube of the instrumented fuel assembly and in-chimney bracket structures subjected to fluid induced vibration are measured. For the analysis of the vibration data, vibration analysis program which can perform basic time and frequency domain analysis, is prepared, and its reliability is verified by comparing the analysis results with those of commercial analysis program(I-DEAS). In time domain analysis, maximum amplitudes, and RMS values of accelerations and displacements from the measured vibration signal, are obtained. The frequency components of the vibration data are analyzed by using the frequency domain analysis. These analysis results show that the levels of the measured vibrations are within the allowable level, and the low frequency component near 10 Hz is dominant in the vibration signal. For the evaluation of the structural integrity on the in-chimney bracket and related structures including the instrumented fuel assembly, the static analysis for ANSYS finite element model is carried out. These analysis results show that the maximum stresses are within the allowable stresses of the ASME code, and the maximum displacement of the top of the flow tube is within the displacement limit. Therefore any damage on the structural integrity is not expected when the irradiation test is performed using the in-chimney bracket

  4. Farewell to the Earth and the Moon -ESA's Mars Express successfully tests its instruments

    Science.gov (United States)

    2003-07-01

    The routine check-outs of Mars Express's instruments and of the Beagle-2 lander, performed during the last weeks, have been very successful. "As in all space missions little problems have arisen, but they have been carefully evaluated and solved. Mars Express continues on its way to Mars performing beautifully", comments Chicarro. The views of the Earth/Moon system were taken on 3 July 2003 by Mars Express's High Resolution Stereo Camera (HRSC), when the spacecraft was 8 million kilometres from Earth. The image taken shows true colours; the Pacific Ocean appears in blue, and the clouds near the Equator and in mid to northern latitudes in white to light grey. The image was processed by the Instrument Team at the Institute of Planetary Research of DLR, Berlin (Germany). It was built by combining a super resolution black and white HRSC snap-shot image of the Earth and the Moon with colour information obtained by the blue, green, and red sensors of the instrument. “The pictures and the information provided by the data prove the camera is working very well. They provide a good indication of what to expect once the spacecraft is in its orbit around Mars, at altitudes of only 250-300 kilometres: very high resolution images with brilliant true colour and in 3D,” says the Principal Investigator of the HRSC, Gerhard Neukum, of the Freie Universität of Berlin (Germany). This camera will be able to distinguish details of up to 2 metres on the Martian surface. Another striking demonstration of Mars Express's instruments high performance are the data taken by the OMEGA spectrometer. Once at Mars, this instrument will provide the best map of the molecular and mineralogical composition of the whole planet, with 5% of the planetary surface in high resolution. Minerals and other compounds such as water will be charted as never before. As the Red Planet is still too far away, the OMEGA team devised an ingenious test for their instrument: to detect the Earth’s surface

  5. Development of Temperature Control Solutions for Non-Instrumented Nucleic Acid Amplification Tests (NINAAT

    Directory of Open Access Journals (Sweden)

    Tamás Pardy

    2017-06-01

    Full Text Available Non-instrumented nucleic acid amplification tests (NINAAT are a novel paradigm in portable molecular diagnostics. They offer the high detection accuracy characteristic of nucleic acid amplification tests (NAAT in a self-contained device, without the need for any external instrumentation. These Point-of-Care tests typically employ a Lab-on-a-Chip for liquid handling functionality, and perform isothermal nucleic acid amplification protocols that require low power but high accuracy temperature control in a single well-defined temperature range. We propose temperature control solutions based on commercially available heating elements capable of meeting these challenges, as well as demonstrate the process by which such elements can be fitted to a NINAAT system. Self-regulated and thermostat-controlled resistive heating elements were evaluated through experimental characterization as well as thermal analysis using the finite element method (FEM. We demonstrate that the proposed solutions can support various NAAT protocols, as well as demonstrate an optimal solution for the loop-mediated isothermal amplification (LAMP protocol. Furthermore, we present an Arduino-compatible open-source thermostat developed for NINAAT applications.

  6. Is It Working? Distractor Analysis Results from the Test Of Astronomy STandards (TOAST) Assessment Instrument

    Science.gov (United States)

    Slater, Stephanie

    2009-05-01

    The Test Of Astronomy STandards (TOAST) assessment instrument is a multiple-choice survey tightly aligned to the consensus learning goals stated by the American Astronomical Society - Chair's Conference on ASTRO 101, the American Association of the Advancement of Science's Project 2061 Benchmarks, and the National Research Council's National Science Education Standards. Researchers from the Cognition in Astronomy, Physics and Earth sciences Research (CAPER) Team at the University of Wyoming's Science and Math Teaching Center (UWYO SMTC) have been conducting a question-by-question distractor analysis procedure to determine the sensitivity and effectiveness of each item. In brief, the frequency each possible answer choice, known as a foil or distractor on a multiple-choice test, is determined and compared to the existing literature on the teaching and learning of astronomy. In addition to having statistical difficulty and discrimination values, a well functioning assessment item will show students selecting distractors in the relative proportions to how we expect them to respond based on known misconceptions and reasoning difficulties. In all cases, our distractor analysis suggests that all items are functioning as expected. These results add weight to the validity of the Test Of Astronomy STandards (TOAST) assessment instrument, which is designed to help instructors and researchers measure the impact of course-length duration instructional strategies for undergraduate science survey courses with learning goals tightly aligned to the consensus goals of the astronomy education community.

  7. Measuring Software Test Verification for Complex Workpieces based on Virtual Gear Measuring Instrument

    Directory of Open Access Journals (Sweden)

    Yin Peili

    2017-08-01

    Full Text Available Validity and correctness test verification of the measuring software has been a thorny issue hindering the development of Gear Measuring Instrument (GMI. The main reason is that the software itself is difficult to separate from the rest of the measurement system for independent evaluation. This paper presents a Virtual Gear Measuring Instrument (VGMI to independently validate the measuring software. The triangular patch model with accurately controlled precision was taken as the virtual workpiece and a universal collision detection model was established. The whole process simulation of workpiece measurement is implemented by VGMI replacing GMI and the measuring software is tested in the proposed virtual environment. Taking involute profile measurement procedure as an example, the validity of the software is evaluated based on the simulation results; meanwhile, experiments using the same measuring software are carried out on the involute master in a GMI. The experiment results indicate a consistency of tooth profile deviation and calibration results, thus verifying the accuracy of gear measuring system which includes the measurement procedures. It is shown that the VGMI presented can be applied in the validation of measuring software, providing a new ideal platform for testing of complex workpiece-measuring software without calibrated artifacts.

  8. Instrumentation of the thermal/structural interactions in situ tests at the Waste Isolation Pilot Plant (WIPP)

    Energy Technology Data Exchange (ETDEWEB)

    Munson, D.E. [Sandia National Labs., Albuquerque, NM (United States). Repository Isolation Systems Div.; Hoag, D.L.; Blankenship, D.A.; DeYonge, W.F.; Schiermeister, D.M. [RE/SPEC, Inc., Albuquerque, NM (United States); Jones, R.L.; Baird, G.T. [Tech Reps, Inc., Albuquerque, NM (United States)

    1997-04-01

    The Department of Energy has constructed the Waste Isolation Pilot Plant (WIPP) to develop the technology for the disposal of radioactive waste from defense programs. Sandia National Laboratories had the responsibility for the experimental activities at the WIPP and fielded several large-scale Thermal/Structural Interactions (TSI) in situ tests to validate techniques used to predict repository performance. The instrumentation of these tests involved the placement of over 4,200 gages including room closure gages, borehole extensometers, stress gages, borehole inclinometers, fixed reference gages, borehole strain gages, thermocouples, thermal flux meters, heater power gages, environmental gages, and ventilation gages. Most of the gages were remotely read instruments that were monitored by an automated data acquisition system, but manually read instruments were also used to provide early deformation information and to provide a redundancy of measurement for the remote gages. Instruments were selected that could operate in the harsh environment of the test rooms and that could accommodate the ranges of test room responses predicted by pretest calculations. Instruments were tested in the field prior to installation at the WIPP site and were modified to improve their performance. Other modifications were made to gages as the TSI tests progressed using knowledge gained from test maintenance. Quality assurance procedures were developed for all aspects of instrumentation including calibration, installation, and maintenance. The instrumentation performed exceptionally well and has produced a large quantity of quality information.

  9. Instrumentation of the thermal/structural interactions in situ tests at the Waste Isolation Pilot Plant (WIPP)

    International Nuclear Information System (INIS)

    Munson, D.E.; Jones, R.L.; Baird, G.T.

    1997-04-01

    The Department of Energy has constructed the Waste Isolation Pilot Plant (WIPP) to develop the technology for the disposal of radioactive waste from defense programs. Sandia National Laboratories had the responsibility for the experimental activities at the WIPP and fielded several large-scale Thermal/Structural Interactions (TSI) in situ tests to validate techniques used to predict repository performance. The instrumentation of these tests involved the placement of over 4,200 gages including room closure gages, borehole extensometers, stress gages, borehole inclinometers, fixed reference gages, borehole strain gages, thermocouples, thermal flux meters, heater power gages, environmental gages, and ventilation gages. Most of the gages were remotely read instruments that were monitored by an automated data acquisition system, but manually read instruments were also used to provide early deformation information and to provide a redundancy of measurement for the remote gages. Instruments were selected that could operate in the harsh environment of the test rooms and that could accommodate the ranges of test room responses predicted by pretest calculations. Instruments were tested in the field prior to installation at the WIPP site and were modified to improve their performance. Other modifications were made to gages as the TSI tests progressed using knowledge gained from test maintenance. Quality assurance procedures were developed for all aspects of instrumentation including calibration, installation, and maintenance. The instrumentation performed exceptionally well and has produced a large quantity of quality information

  10. Summary report of the experimental fast reactor JOYO MK-III performance test

    International Nuclear Information System (INIS)

    Maeda, Yukimoto; Aoyama, Takafumi; Yoshida, Akihiro

    2004-03-01

    An upgrading project (MK-III project) was started to improve the irradiation capability of the experimental fast reactor JOYO. In this project, core replacement and increase of the reactor thermal power by the factor 1.4 were necessary for increasing the maximum fast neutron flux by the factor 1.3 and doubling the capacity for irradiation rigs. The modification of the cooling system that included the replacement of the main intermediate heat exchangers and the dump heat exchangers was completed in September 2000. After a series of system function tests, the performance test, of which objective is to fully characterize the upgraded core and heat transfer system, was started in June 2003. Twenty eight tests were selected and carried out as performance test, in order to confirm that the whole plant satisfy the design criteria and have sufficient characteristics (data necessary for safe and steady operation, core management, reactor control and monitoring) as an irradiation bed. After attaining the initial criticality of the core on 2nd July 2003, core characteristics (the excess reactivity, the isotherm temperature reactivity coefficient, the power reactivity coefficient and so on), plant characteristics (the plant heat balance, the adjustment of the temperature control system, the plant behavior at transient), shielding characteristics (dose rate distribution). As the result, it was confirmed that all the criteria regulated was satisfied and the core and plant have sufficient margins for full power operation, which was increased by the factor 1.4. Especially, nuclear analysis accuracy was verified by comparing the calculation with measured core characteristics of the initial core which consists of fifty five fresh fuel subassemblies. The operational data which is supposed to be useful for developing in-core anomaly detection system were also obtained. The operation manual and training simulator and design of next reactor development were revised based on the results

  11. Instrumentation measurement and testing complex for detection and identification of radioactive materials using the emitted radiation

    International Nuclear Information System (INIS)

    Samossadny, V.T.; Dmitrenko, V.V.; Kadlin, V.V.; Kolesnikov, S.V.; Ulin, S.E.; Grachev, V.M.; Vlasik, K.F.; Dedenko, G.L.; Novikov, D.V.; Uteshev, Z.M.

    2006-01-01

    Simultaneous measurement of neutron and gamma radiation is a very usefull method for effective nuclear materials identification and control. The gamma-ray-neutron complex described in the paper is based on two multi-layer 3 He neutrons detectors and two High Pressure Xenon gamma-ray spectrometers assembled in one unit. All these detectors were callibrated on neutron and gamma-ray sources. The main characteristics of the instrumentation , its testing results and gamma-ray and neutron radiation parameters, which have been measured are represented in the paper. The gamma-neutron sources and fissile materials reliable detection and identification capability was demonstrated

  12. Response Time Analysis and Test of Protection System Instrument Channels for APR1400 and OPR1000

    International Nuclear Information System (INIS)

    Lee, Chang Jae; Han, Seung; Yun, Jae Hee; Baek, Seung Min; Lee, Sang Jeong

    2015-01-01

    Safety limits are required to maintain the integrity of physical barriers designed to prevent the uncontrolled release of radioactive materials in nuclear power plants. The safety analysis establishes two critical constraints that include an analytical limit in terms of a measured or calculated variable, and a specific time after the analytical limit is reached to begin protective action. Keeping with the nuclear regulations and industry standards, satisfying these two requirements will ensure that the safety limit will not be exceeded during the design basis event, either an anticipated operational occurrence or a postulated accident. Various studies on the setpoint determination methodology for the safety-related instrumentation have been actively performed to ensure that the requirement of the analytical limit is satisfied. In particular, the protection setpoint methodology for the advanced power reactor 1400 (APP1400) and the optimized power reactor 1000 (OPR1000) has been recently developed to cover both the design basis event and the beyond design basis event. The developed setpoint methodology has also been quantitatively validated using specific computer programs and setpoint calculations. However, the safety of nuclear power plants cannot be fully guaranteed by satisfying the requirement of the analytical limit. In spite of the response time verification requirements of nuclear regulations and industry standards, it is hard to find the studies on the systematically integrated methodology regarding the response time evaluation. In cases of APR1400 and OPR1000, the response time analysis for the plant protection system is partially included in the setpoint calculation and the response time test is separately performed via the specific plant procedure. The test technique has a drawback which is the difficulty to demonstrate completeness of timing test. The analysis technique has also a demerit of resulting in extreme times that not actually possible. Thus

  13. Response Time Analysis and Test of Protection System Instrument Channels for APR1400 and OPR1000

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Jae; Han, Seung; Yun, Jae Hee; Baek, Seung Min [Department of Instrumentation and Control System Engineering, KEPCO Engineering and Construction, Daejeon (Korea, Republic of); Lee, Sang Jeong [Department of Electronics Engineering, Chungnam National University, Daejeon (Korea, Republic of)

    2015-07-01

    Safety limits are required to maintain the integrity of physical barriers designed to prevent the uncontrolled release of radioactive materials in nuclear power plants. The safety analysis establishes two critical constraints that include an analytical limit in terms of a measured or calculated variable, and a specific time after the analytical limit is reached to begin protective action. Keeping with the nuclear regulations and industry standards, satisfying these two requirements will ensure that the safety limit will not be exceeded during the design basis event, either an anticipated operational occurrence or a postulated accident. Various studies on the setpoint determination methodology for the safety-related instrumentation have been actively performed to ensure that the requirement of the analytical limit is satisfied. In particular, the protection setpoint methodology for the advanced power reactor 1400 (APP1400) and the optimized power reactor 1000 (OPR1000) has been recently developed to cover both the design basis event and the beyond design basis event. The developed setpoint methodology has also been quantitatively validated using specific computer programs and setpoint calculations. However, the safety of nuclear power plants cannot be fully guaranteed by satisfying the requirement of the analytical limit. In spite of the response time verification requirements of nuclear regulations and industry standards, it is hard to find the studies on the systematically integrated methodology regarding the response time evaluation. In cases of APR1400 and OPR1000, the response time analysis for the plant protection system is partially included in the setpoint calculation and the response time test is separately performed via the specific plant procedure. The test technique has a drawback which is the difficulty to demonstrate completeness of timing test. The analysis technique has also a demerit of resulting in extreme times that not actually possible. Thus

  14. Power ramp tests of MOX fuel rods. HBWR irradiation with the instrument rig, IFA-591

    International Nuclear Information System (INIS)

    Ozawa, Takayuki; Abe, Tomoyuki

    2006-03-01

    Plutonium-uranium mixed oxide (MOX) fuel rods of instrumental rig IFA-591 were ramped in HBWR to study the Advanced Thermal Reactor (ATR) MOX fuel behavior during transient operation and to determine a failure threshold of the MOX fuel rods. Eleven segments were base-irradiated in ATR 'FUGEN' up to 18.4 GWd/t. Zirconium liner claddings were adopted for four segments of them. As the results of non-destructive post irradiation examinations (PIEs) after the base-irradiation and before the ramp tests, no remarkable behavior affecting the integrity of fuel assembly and fuel rod was confirmed. All segments to be used for the ramp tests, which consisted of the multi-step ramp tests and the single-step ramp tests, had instrumentations for in-pile measurements of cladding elongation or plenum pressure, and heated up to the maximum linear power of 58.3-68.4 kW/m without failure. The major results of ramp tests are as follows: There is no difference in PCMI behaviors between two type rods of Zry-2 and Zirconium liner claddings from the in-pile measurements of cladding elongation and plenum pressure. The computations of cladding elongation and inner pressure gave slightly lower elongation and pressure than the in-pile measurements during the ramp-test. However, the cladding relaxation during the power hold was in good agreement, and the fission gas release behavior during cooling down could be evaluated by taking into account the relaxation of contact pressure between pellet and cladding. Although the final power during IFA-591 ramp tests reached the higher linear power than the failure threshold power of UO 2 fuel rods, no indication of fuel failure was observed during the ramp tests. The cladding relaxation due to the creep deformation of the MOX pellets at high temperature could be confirmed at the power steps during the multi-ramp test. The fission gas release due to the emancipation from PCMI stress was observed during the power decreasing. The burn-up dependence could be

  15. Gas Generation from K East Basin Sludges and Irradiated Metallic Uranium Fuel Particles Series III Testing

    International Nuclear Information System (INIS)

    Schmidt, Andrew J.; Delegard, Calvin H.; Bryan, Samuel A.; Elmore, Monte R.; Sell, Rachel L.; Silvers, Kurt L.; Gano, Susan R.; Thornton, Brenda M.

    2003-01-01

    The path forward for managing of Hanford K Basin sludge calls for it to be packaged, shipped, and stored at T Plant until final processing at a future date. An important consideration for the design and cost of retrieval, transportation, and storage systems is the potential for heat and gas generation through oxidation reactions between uranium metal and water. This report, the third in a series (Series III), describes work performed at the Pacific Northwest National Laboratory (PNNL) to assess corrosion and gas generation from irradiated metallic uranium particles (fuel particles) with and without K Basin sludge addition. The testing described in this report consisted of 12 tests. In 10 of the tests, 4.3 to 26.4 g of fuel particles of selected size distribution were placed into 60- or 800-ml reaction vessels with 0 to 100 g settled sludge. In another test, a single 3.72-g fuel fragment (i.e., 7150-mm particle) was placed in a 60 ml reaction vessel with no added sludge. The twelfth test contained only sludge. The fuel particles were prepared by crushing archived coupons (samples) from an irradiated metallic uranium fuel element. After loading the sludge materials (whether fuel particles, mixtures of fuel particles and sludge, or sludge-only) into reaction vessels, the solids were covered with an excess of K Basin water, the vessels closed and connected to a gas measurement manifold, and the vessels back-flushed with inert neon cover gas. The vessels were then heated to a constant temperature. The gas pressures and temperatures were monitored continuously from the times the vessels were purged. Gas samples were collected at various times during the tests, and the samples analyzed by mass spectrometry. Data on the reaction rates of uranium metal fuel particles with water as a function of temperature and particle size were generated. The data were compared with published studies on metallic uranium corrosion kinetics. The effects of an intimate overlying sludge layer

  16. Evaluation of a draft standard on performance specifications for health physics instrumentation. Initial results for radiological tests

    International Nuclear Information System (INIS)

    Swinth, K.L.; Kenoyer, J.L.; Mileham, A.P.; Kathren, R.L.; Selby, J.M.

    1983-06-01

    The draft ANSI standard N42.17D2 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. The primary objective of the project is the evaluation of the applicability and practicality of the proposed standard through testing of a cross-section of currently available commercial instruments to determine how well they conform to the standard. The standard is being tested against instruments such as ionization chambers, G.M. detectors, alpha survey meters, and neutron dose equivalent survey meters. This paper presents results of the preliminary radiological performance tests on ionization chambers and G.M. detectors. This includes both the data generated during the tests and a discussion of procedures developed to perform the testing. Results are reported for response time, accuracy, precision, radiation overloads, and angular dependence. In addition, results are reported for parameters that affect instrument performance including battery lifetime, geotropism and stability. Initial test indicates that some of the instruments will not meet the criteria specified in ANSI N42.17D2. Results cover approximately 40 instruments that have been obtained by direct purchase, by loan from instrument vendors or by loan from others including DOE licensees

  17. The Design and Manufacturing Report of Plug Type Non-Instrumented Rig for Irradiation Test in HANARO OR Hole

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Bang, Je Geon; Lim, Ik Sung; Kim, Sun Ki; Yang, Yong Sik; Song, Kun Woo

    2008-09-15

    This project is developed the plug type non-instrumented irradiation test rig of the advanced nuclear fuel in HANARO for pursuit advanced performance in High Performance Fuel Technology Development as a part Nuclear Mid and Long-term R and D Program. This irradiation rig was confirmed the integrity and HANARO core compatibility by the optimum design and the thermal hydraulic out-pile test in FIVPET. The characteristic of plug type non-instrument rig is to possible irradiation test of variable in-pile condition and reduced the wastes for reusable as function. This plug type non-instrumented rig was satisfied the quality assurance requirements and written out the end of manufacturing report. This plug type non-instrumented rig is adopt to the irradiation test for nuclear fuel irradiation test in HANARO OR hole.

  18. Propriedades psicométricas dos itens do teste WISC-III Propiedades psicométricas de los ítenes del subtest WISC-III Psychometric properties of WISC-III items

    Directory of Open Access Journals (Sweden)

    Vera Lúcia Marques de Figueiredo

    2008-09-01

    Full Text Available O aperfeiçoamento de um teste se dá através da seleção, substituição ou revisão de itens, e quando um item é analisado, aumenta a validade e precisão do teste. Este artigo trata da apresentação dos resultados relativos às propriedades psicométricas dos itens dos subtestes do WISC-III, referentes a dificuldade, discriminação e validade. O WISC-III é um instrumento amplamente utilizado no contexto da avaliação da inteligência, e conhecer a qualidade dos itens é essencial ao profissional que administra o teste. As análises foram efetuadas com base nas pontuações de 801 protocolos do teste, aplicados por ocasião da pesquisa de adaptação a um contexto brasileiro. As análises mostraram que os itens adaptados apresentaram características psicométricas adequadas, possibilitando a utilização do instrumento como meio confiável de diagnóstico.El perfeccionamiento de un teste ocurre por la selección, sustitución o revisión de ítenes y, cuando un item es analisado, aumenta la validez y fiabilidad del teste. Ese artículo trata de la presentación de los resultados relativos a las propiedades psicométricas de los ítenes del subtest WISC-III, referentes a la dificultad, a la discriminación y a la validez. El WISC-III es un instrumento muy utilizado en el contexto de la evaluación de la inteligencia, y conocer a la calidad de los ítenes es esencial al profesional que administra el teste. Los análisis fueron efectuados con base el los puntajes de 801 protocolos de registro del teste, aplicados por ocasión de encuesta de estandarización a un contexto brasileño. Los análisis enseñaron que los ítenes adaptados apuntaron características psicométricas adecuadas, permitiendo la utilización del instrumento como medio confiable de diagnóstico.The improvement of the quality of items by selection, substitution and review will increase a test's validity and reliability. Current essay will present results referring to

  19. Measuring mechanisms for quality assurance in primary care systems in transition: test of a new instrument in Slovenia and Uzbekistan.

    NARCIS (Netherlands)

    Kringos, D.S.; Boerma, W.G.W.; Pellny, M.

    2009-01-01

    Aim: This WHO study, carried out by the authors, aimed to develop and field test an instrument to assess the availability of structures and mechanisms for managing quality in primary care in countries in transition. Methods: The instrument is based on a literature study, consensus meetings with

  20. First Results from the Test Of Astronomy STandards (TOAST) Assessment Instrument

    Science.gov (United States)

    Slater, Stephanie

    2009-01-01

    Considerable effort in the astronomy education research over the past several years has focused on developing assessment tools in the form of multiple-choice conceptual diagnostics and content knowledge surveys. This has been critically important in advancing astronomy as a sub-discipline of physics education research, allowing researchers to establish the initial knowledge state of students as well as to attempt to measure some of the impacts of innovative instructional interventions. Before now, few of the existing instruments were constructed upon a solid list of clearly articulated and widely agreed upon learning objectives. Moving beyond the 10-year old Astronomy Diagnostics Test, we have developed and validated a new assessment instrument that is tightly aligned to the consensus learning goals stated by the American Astronomical Society - Chair's Conference on ASTRO 101, the American Association of the Advancement of Science's Project 2061 Benchmarks, and the National Research Council's National Science Education Standards. Researchers from the Cognition in Astronomy, Physics and Earth sciences Research (CAPER) Team at the University of Wyoming's Science and Math Teaching Center (UWYO SMTC) designed a criterion-referenced assessment tool, called the Test Of Astronomy STandards (TOAST). Through iterative development, this multiple-choice instrument has a high degree of reliability and validity for instructors and researchers needing information on students’ initial knowledge state at the beginning of a course and can be used, in aggregate, to help measure the impact of course-length duration instructional strategies for undergraduate science survey courses with learning goals tightly aligned to the consensus goals of the astronomy education community.

  1. An instrument for real time detection of contamination in space environmental tests chambers

    Science.gov (United States)

    Richmond, R. G.; Harmon, H. N.

    1972-01-01

    An instrument for in situ vacuum detection of surface reflectance changes at 1216A was designed. Using successive reflections, this instrument is more sensitive as an indicator of reflectance changes than similar instruments having only a single reflection. The selection of each component of the instrument and its operational performance is discussed.

  2. Investigation of irradiation embrittlement and annealing behaviour of JRQ pressure vessel steel by instrumented impact tests

    Energy Technology Data Exchange (ETDEWEB)

    Valo, M; Rintamaa, R; Nevalainen, M; Wallin, K; Torronen, K [Technical Research Centre of Finland, Espoo (Finland); Tipping, P [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1994-12-31

    Seven series of A533-B type pressure vessel steel specimens irradiated as well as irradiated - annealed - re-irradiated to different fast neutron fluences (up to 5.10{sup 19}/cm{sup 2}) have been tested with a new type of instrumented impact test machine. The radiation embrittlement and the effect of the intermediate annealing was assessed by using the ductile and cleavage fracture initiation toughness. Although the ductile fracture initiation toughness exhibited scatter, the transition temperature shift corresponding to the dynamic cleavage fracture initiation agreed well with the 41 J Charpy-V shift. The results indicate that annealing is beneficial in restoring mechanical properties in an irradiated nuclear pressure vessel steel. (authors). 8 refs., 11 figs., 1 tab.

  3. The multipurpose thermalhydraulic test facility TOPFLOW: an overview on experimental capabilities, instrumentation and results

    International Nuclear Information System (INIS)

    Prasser, H.M.; Beyer, M.; Carl, H.; Manera, A.; Pietruske, H.; Schuetz, P.; Weiss, F.P.

    2006-01-01

    A new multipurpose thermalhydraulic test facility TOPFLOW (TwO Phase FLOW) was built and put into operation at Forschungszentrum Rossendorf in 2002 and 2003. Since then, it has been mainly used for the investigation of generic and applied steady state and transient two phase flow phenomena and the development and validation of models of computational fluid dynamic (CFD) codes in the frame of the German CFD initiative. The advantage of TOPFLOW consists in the combination of a large scale of the test channels with a wide operational range both of the flow velocities as well as of the system pressures and temperatures plus finally the availability of a special instrumentation that is capable in high spatial and temporal resolving two phase flow phenomena, for example the wire-mesh sensors. (orig.)

  4. Trace Gas Measurements from the GeoTASO and GCAS Airborne Instruments: An Instrument and Algorithm Test-Bed for Air Quality Observations from Geostationary Orbit

    Science.gov (United States)

    Nowlan, C. R.; Liu, X.; Janz, S. J.; Leitch, J. W.; Al-Saadi, J. A.; Chance, K.; Cole, J.; Delker, T.; Follette-Cook, M. B.; Gonzalez Abad, G.; Good, W. S.; Kowalewski, M. G.; Loughner, C.; Pickering, K. E.; Ruppert, L.; Soo, D.; Szykman, J.; Valin, L.; Zoogman, P.

    2016-12-01

    The Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) and the GEO-CAPE Airborne Simulator (GCAS) instruments are pushbroom sensors capable of making remote sensing measurements of air quality and ocean color. Originally developed as test-bed instruments for the Geostationary Coastal and Air Pollution Events (GEO-CAPE) decadal survey, these instruments are now also part of risk reduction for the upcoming Tropospheric Emissions: Monitoring of Pollution (TEMPO) and Geostationary Environment Monitoring Spectrometer (GEMS) geostationary satellite missions, and will provide validation capabilities after the satellite instruments are in orbit. GeoTASO and GCAS flew on two different aircraft in their first intensive air quality field campaigns during the DISCOVER-AQ missions over Texas in 2013 and Colorado in 2014. GeoTASO was also deployed in 2016 during the KORUS-AQ field campaign to make measurements of trace gases and aerosols over Korea. GeoTASO and GCAS collect spectra of backscattered solar radiation in the UV and visible that can be used to derive 2-D maps of trace gas columns below the aircraft at spatial resolutions on the order of 250 x 500 m. We present spatially resolved maps of trace gas retrievals of ozone, nitrogen dioxide, formaldehyde and sulfur dioxide over urban areas and power plants from flights during the field campaigns, and comparisons with data from ground-based spectrometers, in situ monitoring instruments, and satellites.

  5. Design and manufacturing of non-instrumented capsule for advanced PWR fuel pellet irradiation test in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. H.; Lee, C. B.; Song, K. W. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-04-01

    This project is preparing to irradiation test of the developed large grain UO{sub 2} fuel pellet in HANARO for pursuit fuel safety and high burn-up in 'Advanced LWR Fuel Technology Development Project' as a part Nuclear Mid and Long-term R and D Program. On the basis test rod is performed the nuclei property and preliminary fuel performance analysis, test rod and non-instrumented capsule are designed and manufactured for irradiation test in HANARO. This non-instrumented irradiation capsule of Advanced PWR Fuel pellet was referred the non-instrumented capsule for an irradiation test of simulated DUPIC fuel in HANARO(DUPIC Rig-001) and 18-element HANARO fuel, was designed to ensure the integrity and the endurance of non-instrumented capsule during the long term(2.5 years) irradiation. To irradiate the UO{sub 2} pellets up to the burn-up 70 MWD/kgU, need the time about 60 months and ensure the integrity of non-instrumented capsule for 30 months until replace the new capsule. This non-instrumented irradiation capsule will be based to develope the non-instrumented capsule for the more long term irradiation in HANARO. 22 refs., 13 figs., 5 tabs. (Author)

  6. Modeling safety instrumented systems with MooN voting architectures addressing system reconfiguration for testing

    International Nuclear Information System (INIS)

    Torres-Echeverria, A.C.; Martorell, S.; Thompson, H.A.

    2011-01-01

    This paper addresses the modeling of probability of dangerous failure on demand and spurious trip rate of safety instrumented systems that include MooN voting redundancies in their architecture. MooN systems are a special case of k-out-of-n systems. The first part of the article is devoted to the development of a time-dependent probability of dangerous failure on demand model with capability of handling MooN systems. The model is able to model explicitly common cause failure and diagnostic coverage, as well as different test frequencies and strategies. It includes quantification of both detected and undetected failures, and puts emphasis on the quantification of common cause failure to the system probability of dangerous failure on demand as an additional component. In order to be able to accommodate changes in testing strategies, special treatment is devoted to the analysis of system reconfiguration (including common cause failure) during test of one of its components, what is then included in the model. Another model for spurious trip rate is also analyzed and extended under the same methodology in order to empower it with similar capabilities. These two models are powerful enough, but at the same time simple, to be suitable for handling of dependability measures in multi-objective optimization of both system design and test strategies for safety instrumented systems. The level of modeling detail considered permits compliance with the requirements of the standard IEC 61508. The two models are applied to brief case studies to demonstrate their effectiveness. The results obtained demonstrated that the first model is adequate to quantify time-dependent PFD of MooN systems during different system states (i.e. full operation, test and repair) and different MooN configurations, which values are averaged to obtain the PFD avg . Also, it was demonstrated that the second model is adequate to quantify STR including spurious trips induced by internal component failure and

  7. Bank liquidity-stress testing and Basel III implementation in Indonesia

    Directory of Open Access Journals (Sweden)

    Mohamad Adam

    2016-03-01

    Full Text Available This study analyzes the possibility of the implementation of the Basel III, namely the rules of banking sector. The population analyzed in this study comprises the 120 banks in Indonesia. The result shows that Indonesian banking sector has tremendous value if the Basel III standards is applied in Indonesia. Bank BCA has the lowest values with a score of 8.89 while Bank BRI has the highest value with a score of 9.68. This study concludes that the standard rules of Basel III would be able to be implemented in Indonesia.

  8. Bank Liquidity-stress Testing and Basel III Implementation in Indonesia

    OpenAIRE

    Adam, Mohamad; Taufik, Taufik; Prathama, Muhammad Aditya Erfiyan

    2015-01-01

    This study analyzes the possibility of the implementation of the Basel III, namely the rules of banking sector. The population analyzed in this study comprises the 120 banks in Indonesia. The result shows that Indonesian banking sector has tremendous value if the Basel III standards is applied in Indonesia. Bank BCA has the lowest values with a score of 8.89 while Bank BRI has the highest value with a score of 9.68. This study concludes that the standard rules of Basel III would be able to be...

  9. Occupant kinematics in low-speed frontal sled tests: Human volunteers, Hybrid III ATD, and PMHS.

    Science.gov (United States)

    Beeman, Stephanie M; Kemper, Andrew R; Madigan, Michael L; Franck, Christopher T; Loftus, Stephen C

    2012-07-01

    A total of 34 dynamic matched frontal sled tests were performed, 17 low (2.5g, Δv=4.8kph) and 17 medium (5.0g, Δv=9.7kph), with five male human volunteers of approximately 50th percentile height and weight, a Hybrid III 50th percentile male ATD, and three male PMHS. Each volunteer was exposed to two impulses at each severity, one relaxed and one braced prior to the impulse. A total of four tests were performed at each severity with the ATD and one trial was performed at each severity with each PMHS. A Vicon motion analysis system, 12 MX-T20 2 megapixel cameras, was used to quantify subject 3D kinematics (±1mm) (1kHz). Excursions of select anatomical regions were normalized to their respective initial positions and compared by test condition and between subject types. The forward excursions of the select anatomical regions generally increased with increasing severity. The forward excursions of relaxed human volunteers were significantly larger than those of the ATD for nearly every region at both severities. The forward excursions of the upper body regions of the braced volunteers were generally significantly smaller than those of the ATD at both severities. Forward excursions of the relaxed human volunteers and PMHSs were fairly similar except the head CG response at both severities and the right knee and C7 at the medium severity. The forward excursions of the upper body of the PMHS were generally significantly larger than those of the braced volunteers at both severities. Forward excursions of the PMHSs exceeded those of the ATD for all regions at both severities with significant differences within the upper body regions. Overall human volunteers, ATD, and PMHSs do not have identical biomechanical responses in low-speed frontal sled tests but all contribute valuable data that can be used to refine and validate computational models and ATDs used to assess injury risk in automotive collisions. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. A Unique Outside Neutron and Gamma Ray Instrumentation Development Test Facility at NASA's Goddard Space Flight Center

    Science.gov (United States)

    Bodnarik, J.; Evans, L.; Floyd, S.; Lim, L.; McClanahan, T.; Namkung, M.; Parsons, A.; Schweitzer, J.; Starr, R.; Trombka, J.

    2010-01-01

    An outside neutron and gamma ray instrumentation test facility has been constructed at NASA's Goddard Space Flight Center (GSFC) to evaluate conceptual designs of gamma ray and neutron systems that we intend to propose for future planetary lander and rover missions. We will describe this test facility and its current capabilities for operation of planetary in situ instrumentation, utilizing a l4 MeV pulsed neutron generator as the gamma ray excitation source with gamma ray and neutron detectors, in an open field with the ability to remotely monitor and operate experiments from a safe distance at an on-site building. The advantage of a permanent test facility with the ability to operate a neutron generator outside and the flexibility to modify testing configurations is essential for efficient testing of this type of technology. Until now, there have been no outdoor test facilities for realistically testing neutron and gamma ray instruments planned for solar system exploration

  11. Myth of the Master Detective: Reliability of Interpretations for Kaufman's "Intelligent Testing" Approach to the WISC-III.

    Science.gov (United States)

    Macmann, Gregg M.; Barnett, David W.

    1997-01-01

    Used computer simulation to examine the reliability of interpretations for Kaufman's "intelligent testing" approach to the Wechsler Intelligence Scale for Children (3rd ed.) (WISC-III). Findings indicate that factor index-score differences and other measures could not be interpreted with confidence. Argues that limitations of IQ testing…

  12. ROLE OF IRON (II, III) HYDROXYCARBONATE GREEN RUST IN ARSENIC REMEDIATION USING ZEROVALENT IRON IN COLUMN TESTS

    Science.gov (United States)

    We examined corrosion products of zerovalent iron (Peerless iron) that was used in three column tests for removing arsenic under dynamic flow conditions with and without added phosphate and silicate. Iron(II, III) hydroxycarbonate and magnetite were major iron corrosion products...

  13. Rorschach and the WAIS-III after one and two years of psychotherapy O teste de Rorschach e a Escala WAIS-III após um e dois Anos de psicoterapia

    Directory of Open Access Journals (Sweden)

    Latife Yazigi

    2011-01-01

    Full Text Available This study aimed at identifying what aspects of personality are modified after one and two years of psychoanalytic psychotherapy in adults attending a free university healthcare service in São Paulo, Brazil. The instruments were the Rorschach and the WAIS-III tests which were administered before and after one and two years of treatment. The participants were 34 adult individuals, both genders. After one year of psychotherapy in the Rorschach method there was an increase in effective and adaptive interpersonal relationship, an enhancement in sensitiveness related to the capacity of modulating affect, the need for close contact as well as the arousal of feelings of discomfort associated with intensification of self-regard, and a decrease in narcissistic tendencies. As well as in WAIS-III, there was an increase in motivation, attention and speed processing.O estudo teve por objetivo identificar quais aspectos da personalidade são modificados após um e dois anos de psicoterapia psicanalítica em adultos atendidos em um serviço público de saúde mental de uma universidade em São Paulo, no Brasil. Os instrumentos utilizados foram o Rorschach e a Escala de Inteligência Wechsler para adultos (WAIS-III, os quais foram administrados antes e após um e dois anos de tratamento. Os participantes foram 34 indivíduos adultos, de ambos os sexos. No Rorschach, após um ano de psicoterapia, ocorreu melhora da relação interpessoal adaptada e efetiva, melhora na sensibilidade relacionada à capacidade de modular afeto e da necessidade de contato mais próximo, e surgimento de sentimentos de desconforto associados à intensificação de auto-observação e diminuição de tendências narcisistas. No WAIS-III houve aumento de motivação, melhora atencional e de velocidade de processamento.

  14. Service quality in banking: developing and testing measurement instrument with Latvian sample data

    Directory of Open Access Journals (Sweden)

    Jelena Titko

    2013-01-01

    Full Text Available The paper highlights the importance of managing service quality in banking that can positively affect customer satisfaction. The goal of the given study is to develop an instrument for measuring service quality perceived by Latvian banks’ retail customers and to determine the most important contributors to customer satisfaction. To achieve this purpose, randomly selected customers of Latvian banks were surveyed, using the authors’ developed questionnaire. The proposed instrument was tested for reliability and validity, using techniques of confirmatory factor analysis. Exploratory factor analysis yielded five service quality dimensions (factors that allowed constructing customer satisfaction factor model EPICA: E – expenses, P – product, I – image, C – competence and emotional intellect, A – access. The subsequent correlation analysis revealed that the strongest relationship is between customer satisfaction and C factor. The results of the current research are crucially important for Latvian banks’ executives because the majority of previous studies in the related field offered measurement scales adequate for measuring service quality in other industries. Besides, the proposed questionnaire is exclusively developed for Latvia and considers Latvian banking sector specifics.

  15. Power supply for control and instrumentation in Fast Breeder Test Reactor

    International Nuclear Information System (INIS)

    Raghavan, K.; Shanmugam, T.K.

    1977-01-01

    The design and operation of the four 'no-break' power supplies for control and instrumentation in the Fast Breeder Test Reactor (FBTR), Kalpakkam, are described. Interruptions in the power supplies are eliminated by redundancy and battery back-up source while voltage dips and transients are taken care by automatic regulation system. The four power supplies are : (1) 24 V D.C. exclusively for neutronic and safety circuits, (2) 48 V D.C. for control logic indication lamps and solenoid valves, (3) 220 V D.C. for switchgear control, control room emergency lighting and D.C. flushing oil pump for the turbine and (4) 220 V A.C. single-phase 50 H/Z for computers and electronics of control and instrumentation. Stationary lead-acid batteries (lead antimony type) in floating mode operation with rectifier/charger are used for emergency back-up. All these power supplies are fed by 415 V, 3-phase, 50 HZ emergency supply buses which are provided with diesel generator back-up. Static energy conversion system (in preference to mechanical rotation system) is used for A.C. to D.C. and also for A.C. to A.C. conversion. (M.G.B.)

  16. A Review and Comparison of the Reliabilities of the MMPI-2, MCMI-III, and PAI Presented in Their Respective Test Manuals

    Science.gov (United States)

    Wise, Edward A.; Streiner, David L.; Walfish, Steven

    2010-01-01

    This article provides a review of the literature to determine the most frequently used personality tests. Based on this review, internal consistency and test-retest reliability coefficients from the test manuals for the Minnesota Multiphasic Personality Inventory-2 (MMPI-2), Millon Clinical Multiaxial Inventory-III (MCMI-III), and Personality…

  17. Instrumental intelligent test of food sensory quality as mimic of human panel test combining multiple cross-perception sensors and data fusion

    International Nuclear Information System (INIS)

    Ouyang, Qin; Zhao, Jiewen; Chen, Quansheng

    2014-01-01

    Highlights: • To develop a novel instrumental intelligent test methodology for food sensory analysis. • A novel data fusion was used in instrumental intelligent test methodology. • Linear and nonlinear tools were comparatively used for modeling. • The instrumental test methodology can be imitative of human test behavior. - Abstract: Instrumental test of food quality using perception sensors instead of human panel test is attracting massive attention recently. A novel cross-perception multi-sensors data fusion imitating multiple mammal perception was proposed for the instrumental test in this work. First, three mimic sensors of electronic eye, electronic nose and electronic tongue were used in sequence for data acquisition of rice wine samples. Then all data from the three different sensors were preprocessed and merged. Next, three cross-perception variables i.e., color, aroma and taste, were constructed using principal components analysis (PCA) and multiple linear regression (MLR) which were used as the input of models. MLR, back-propagation artificial neural network (BPANN) and support vector machine (SVM) were comparatively used for modeling, and the instrumental test was achieved for the comprehensive quality of samples. Results showed the proposed cross-perception multi-sensors data fusion presented obvious superiority to the traditional data fusion methodologies, also achieved a high correlation coefficient (>90%) with the human panel test results. This work demonstrated that the instrumental test based on the cross-perception multi-sensors data fusion can actually mimic the human test behavior, therefore is of great significance to ensure the quality of products and decrease the loss of the manufacturers

  18. Instrumental intelligent test of food sensory quality as mimic of human panel test combining multiple cross-perception sensors and data fusion

    Energy Technology Data Exchange (ETDEWEB)

    Ouyang, Qin; Zhao, Jiewen; Chen, Quansheng, E-mail: qschen@ujs.edu.cn

    2014-09-02

    Highlights: • To develop a novel instrumental intelligent test methodology for food sensory analysis. • A novel data fusion was used in instrumental intelligent test methodology. • Linear and nonlinear tools were comparatively used for modeling. • The instrumental test methodology can be imitative of human test behavior. - Abstract: Instrumental test of food quality using perception sensors instead of human panel test is attracting massive attention recently. A novel cross-perception multi-sensors data fusion imitating multiple mammal perception was proposed for the instrumental test in this work. First, three mimic sensors of electronic eye, electronic nose and electronic tongue were used in sequence for data acquisition of rice wine samples. Then all data from the three different sensors were preprocessed and merged. Next, three cross-perception variables i.e., color, aroma and taste, were constructed using principal components analysis (PCA) and multiple linear regression (MLR) which were used as the input of models. MLR, back-propagation artificial neural network (BPANN) and support vector machine (SVM) were comparatively used for modeling, and the instrumental test was achieved for the comprehensive quality of samples. Results showed the proposed cross-perception multi-sensors data fusion presented obvious superiority to the traditional data fusion methodologies, also achieved a high correlation coefficient (>90%) with the human panel test results. This work demonstrated that the instrumental test based on the cross-perception multi-sensors data fusion can actually mimic the human test behavior, therefore is of great significance to ensure the quality of products and decrease the loss of the manufacturers.

  19. On-line testing of calibration of process instrumentation channels in nuclear power plants. Phase 2, Final report

    International Nuclear Information System (INIS)

    Hashemian, H.M.

    1995-11-01

    The nuclear industry is interested in automating the calibration of process instrumentation channels; this report provides key results of one of the sponsored projects to determine the validity of automated calibrations. Conclusion is that the normal outputs of instrument channels in nuclear plants can be monitored over a fuel cycle while the plant is operating to determine calibration drift in the field sensors and associated signal conversion and signal conditioning equipment. The procedure for on-line calibration tests involving calculating the deviation of each instrument channel from the best estimate of the process parameter that the instrument is measuring. Methods were evaluated for determining the best estimate. Deviation of each signal from the best estimate is updated frequently while the plant is operating and plotted vs time for entire fuel cycle, thereby providing time history plots that can reveal channel drift and other anomalies. Any instrument channel that exceeds allowable drift or channel accuracy band is then scheduled for calibration during a refueling outage or sooner. This provides calibration test results at the process operating point, one of the most critical points of the channel operation. This should suffice for most narrow-range instruments, although the calibration of some instruments can be verified at other points throughout their range. It should be pointed out that the calibration of some process signals such as the high pressure coolant injection flow in BWRs, which are normally off- scale during plant operation, can not be tested on-line

  20. Test-retest reliability and cross validation of the functioning everyday with a wheelchair instrument.

    Science.gov (United States)

    Mills, Tamara L; Holm, Margo B; Schmeler, Mark

    2007-01-01

    The purpose of this study was to establish the test-retest reliability and content validity of an outcomes tool designed to measure the effectiveness of seating-mobility interventions on the functional performance of individuals who use wheelchairs or scooters as their primary seating-mobility device. The instrument, Functioning Everyday With a Wheelchair (FEW), is a questionnaire designed to measure perceived user function related to wheelchair/scooter use. Using consumer-generated items, FEW Beta Version 1.0 was developed and test-retest reliability was established. Cross-validation of FEW Beta Version 1.0 was then carried out with five samples of seating-mobility users to establish content validity. Based on the content validity study, FEW Version 2.0 was developed and administered to seating-mobility consumers to examine its test-retest reliability. FEW Beta Version 1.0 yielded an intraclass correlation coefficient (ICC) Model (3,k) of .92, p content validity results revealed that FEW Beta Version 1.0 captured 55% of seating-mobility goals reported by consumers across five samples. FEW Version 2.0 yielded ICC(3,k) = .86, p content validity of FEW Version 2.0 was confirmed. FEW Beta Version 1.0 and FEW Version 2.0 were highly stable in their measurement of participants' seating-mobility goals over a 1-week interval.

  1. Improved harmonization of eosin-5-maleimide binding test across different instruments and age groups.

    Science.gov (United States)

    Agarwal, Archana M; Liew, Michael A; Nussenzveig, Roberto H; Sangle, Nikhil; Heikal, Nahla; Yaish, Hassan; Christensen, Robert

    2016-11-01

    The eosin-5'maleimide (EMA) binding test has been studied extensively for the detection of hereditary spherocytosis (HS). Its performance characteristics have been compared to NaCl-based or glycerol lysis-based red cell osmotic fragility tests and cryohemolysis. HS samples are also better identified when both mean channel fluorescence (MCF) of EMA relative to controls and the coefficient of variation (CV) are analyzed. We looked at 65 normal controls including 30 adults 25-65 years old and 35 newborns and 12 HS cases. In addition to the MCF and the CV, we used a side scatter (SSC) vs. EMA fluorescence gate or "footprint" to depict where normal erythrocytes should appear. Erythrocytes that have reduced band 3 protein appear outside of the footprint. In our study, newborn data did not cluster with the samples from working age individuals. The MCF and the CVs of normal newborns were higher than normal adult group. However, the footprint data of normal samples relative to their controls was around 99.5% for each group, because the footprint was moved to fit the pattern of the normal. The inclusion of footprint parameter will help in better standardization as well as implementation of this test across different age groups as well as different instruments. © 2015 International Clinical Cytometry Society. © 2015 International Clinical Cytometry Society.

  2. English Language Proficiency and Test Performance: An Evaluation of Bilingual Students with the Woodcock-Johnson III Tests of Cognitive Abilities

    Science.gov (United States)

    Sotelo-Dynega, Marlene; Ortiz, Samuel O.; Flanagan, Dawn P.; Chaplin, William F.

    2013-01-01

    In this article, we report the findings of an exploratory empirical study that investigated the relationship between English Language Proficiency (ELP) on performance on the Woodcock-Johnson Tests of Cognitive Abilities-Third Edition (WJ III) when administered in English to bilingual students of varying levels of ELP. Sixty-one second-grade…

  3. BWR 2 % main recirculation line break LOCA tests RUNs 915 and 920 without HPCS in ROSA-III program

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Nakamura, Hideo; Anoda, Yoshinari; Kumamaru, Hiroshige; Yonomoto, Taisuke; Koizumi, Yasuo; Tasaka, Kanji

    1987-03-01

    This report presents the experimental results of BWR LOCA integral tests, RUNs 915 and 920, which are performed in the ROSA-III program simulating 2 % main recirculation line break LOCA tests with and without pressure control system operation. The ROSA-III test facility simulates a BWR system with volume scale of 1/424 and has four half-length electrically heated fuel bundles, two active recirculation loops, four types of ECCS's, and steam and feedwater systems. The report presents (1) the experimental results of 2 % small break LOCA phanomena in the ROSA-III system and (2) the effects of the pressure control system on the LOCA phenomena. The pressure control system contributed to (A) prevent bulk flashing in the early blowdown phase, (B) early closure of MSIV by L2 level trip, (C) early actuation of ADS by L1 level trip. However, the core thermal responses of the two tests were similar because of the similar mass inventory in PV after the ADS actuation in both tests. (author)

  4. Fabrication and testing of the sintered ceramic UO2 fuel - I - III, Part III - testing of sintered uranium dioxide properties dependent on the fabrication procedure

    International Nuclear Information System (INIS)

    Novakovic, M.; Ristic, M.M.

    1961-12-01

    The objective of this task was testing the influence of some parameters on the properties of sintered UO 2 . The influence of parameters tested were as follows: adhesives; pressure in the pressing procedure; temperature of sintering of the UO 2 powder. Other parameters were chosen according to the theoretical study. Sintering was done in argon atmosphere. Characterization of the UO 2 powder was performed meaning determining the needed chemical, physical and physico-chemical properties. Some new methods were developed within this task: SET method for measuring the specific surfaces, DTA, TGA, high-temperature torsion

  5. Multiobjective optimization of strategies for operation and testing of low-demand safety instrumented systems using a genetic algorithm and fault trees

    International Nuclear Information System (INIS)

    Longhi, Antonio Eduardo Bier; Pessoa, Artur Alves; Garcia, Pauli Adriano de Almada

    2015-01-01

    Since low-demand safety instrumented systems (SISs) do not operate continuously, their failures are often only detected when the system is demanded or tested. The conduction of tests, besides adding costs, can raise risks of failure on demand during their execution and also increase the frequency of spurious activation. Additionally, it is often necessary to interrupt production to carry out tests. In light of this scenario, this paper presents a model to optimize strategies for operation and testing of these systems, applying modeling by fault trees associated with optimization by a genetic algorithm. Its main differences are: (i) ability to represent four modes of operation and test them for each SIS subsystem; (ii) ability to represent a SIS that executes more than one safety instrumented function; (iii) ability to keep track of the down-time generated in the production system; and (iv) alteration of a genetic selection mechanism that permits identification of more efficient solutions with smaller influence on the optimization parameters. These aspects are presented by applying this model in three case studies. The results obtained show the applicability of the proposed approach and its potential to help make more informed decisions. - Highlights: • Models the integrity and cost related to operation and testing of low-demand SISs. • Keeps track of the production down-time generated by SIS tests and repairs. • Allows multiobjective optimization to identify operation and testing strategies. • Enables integrated assessment of an SIS that executes more than one SIF. • Allows altering the selection mechanism to identify the most efficient strategies

  6. James Webb Space Telescope (JWST) Integrated Science Instruments Module (ISIM) Cryo-Vacuum (CV) Test Campaign Summary

    Science.gov (United States)

    Yew, Calinda; Whitehouse, Paul; Lui, Yan; Banks, Kimberly

    2016-01-01

    JWST Integrated Science Instruments Module (ISIM) has completed its system-level testing program at the NASA Goddard Space Flight Center (GSFC). In March 2016, ISIM was successfully delivered for integration with the Optical Telescope Element (OTE) after the successful verification of the system through a series of three cryo-vacuum (CV) tests. The first test served as a risk reduction test; the second test provided the initial verification of the fully-integrated flight instruments; and the third test verified the system in its final flight configuration. The complexity of the mission has generated challenging requirements that demand highly reliable system performance and capabilities from the Space Environment Simulator (SES) vacuum chamber. As JWST progressed through its CV testing campaign, deficiencies in the test configuration and support equipment were uncovered from one test to the next. Subsequent upgrades and modifications were implemented to improve the facility support capabilities required to achieve test requirements. This paper: (1) provides an overview of the integrated mechanical and thermal facility systems required to achieve the objectives of JWST ISIM testing, (2) compares the overall facility performance and instrumentation results from the three ISIM CV tests, and (3) summarizes lessons learned from the ISIM testing campaign.

  7. Realisation and instrumentation of high current power station for superconducting cables testing

    International Nuclear Information System (INIS)

    Regnaud, S.

    2000-05-01

    This report deals with the designing of a high current station able to test electric properties of superconductors. This test station will be used for testing the superconducting wires of large hadron collider detectors in CERN. The high current test station will have to generate high intensity continuous current in a magnetic field of 0 to 5 tesla and in temperature conditions of 4.2 K. The length of wire samples submitted to the uniform magnetic field is 300 mm and the installation is fitted with equipment able to measure the magnetic field perpendicular to either faces of the wire. The peculiarity of this station is to use a superconducting transformer in order to generate the high current. The first part of this work recalls important notions concerning superconductivity. The second part presents the high current station by describing the superconducting transformer and the sample-holder. We have studied the designing of a transformer able to yield a secondary current whose intensity reaches 100 kA, such intensity generates powerful electromagnetic forces (566 kN/m) in case of defect, so the sample-holder has to be carefully design to bear them. The third part presents the cryogenic component of the station, the instrumentation of the sample-holder and the method used to measure secondary currents. In the last part we present the performance of a prototype transformer, this prototype is able to deliver a 22 kA secondary current for a 160 A primary current, the uncertainty on the measured value of the secondary current is about 3%

  8. Development and test of the ZELT-3D computer code for unfolding power distributions using side reflector instrumentation signals

    International Nuclear Information System (INIS)

    Knob, P.J.

    1983-01-01

    The impossibility of using internal instrumentation in high temperature reactor with spherical fuel, lead to the development of an instrumentation system that will be able to monitorate power perturbations only using detectors located in the reflectors. This instrumentation is divided in three parts: one for each reflector, higher, lower and lateral. The development of a system located in the lateral reflector is shown. The system was tested for Kahter from IRE-KFA of very low dimensions and for the PNP-300 power reactor of very large dimensions. Good results were obtained. (E.G.) [pt

  9. Fabrication and Testing of a Modular Micro-Pocket Fission Detector Instrumentation System for Test Nuclear Reactors

    Science.gov (United States)

    Reichenberger, Michael A.; Nichols, Daniel M.; Stevenson, Sarah R.; Swope, Tanner M.; Hilger, Caden W.; Roberts, Jeremy A.; Unruh, Troy C.; McGregor, Douglas S.

    2018-01-01

    Advancements in nuclear reactor core modeling and computational capability have encouraged further development of in-core neutron sensors. Measurement of the neutron-flux distribution within the reactor core provides a more complete understanding of the operating conditions in the reactor than typical ex-core sensors. Micro-Pocket Fission Detectors have been developed and tested previously but have been limited to single-node operation and have utilized highly specialized designs. The development of a widely deployable, multi-node Micro-Pocket Fission Detector assembly will enhance nuclear research capabilities. A modular, four-node Micro-Pocket Fission Detector array was designed, fabricated, and tested at Kansas State University. The array was constructed from materials that do not significantly perturb the neutron flux in the reactor core. All four sensor nodes were equally spaced axially in the array to span the fuel-region of the reactor core. The array was filled with neon gas, serving as an ionization medium in the small cavities of the Micro-Pocket Fission Detectors. The modular design of the instrument facilitates the testing and deployment of numerous sensor arrays. The unified design drastically improved device ruggedness and simplified construction from previous designs. Five 8-mm penetrations in the upper grid plate of the Kansas State University TRIGA Mk. II research nuclear reactor were utilized to deploy the array between fuel elements in the core. The Micro-Pocket Fission Detector array was coupled to an electronic support system which has been specially developed to support pulse-mode operation. The Micro-Pocket Fission Detector array composed of four sensors was used to monitor local neutron flux at a constant reactor power of 100 kWth at different axial locations simultaneously. The array was positioned at five different radial locations within the core to emulate the deployment of multiple arrays and develop a 2-dimensional measurement of

  10. Irradiation test on connector part for nuclear instrumentation of nuclear powered ship 'Mutsu'

    International Nuclear Information System (INIS)

    Kudo, Takahiro; Mizushima, Toshihiko; Tsunoda, Tsunemi; Nakazawa, Toshio

    1991-01-01

    The nuclear instrumetnation facility of the nuclear powered ship 'Mutsu' is composed of neutron detectors, signal cables and the circuits for measurement, and ocntinuously monitors neutron flux. Since this facility treats very faint signals, for the signal cables, coaxial cables and triple coaxial cables are used. The coaxial cables for the nuclear instrumentation are equipped with connectors at both ends, and those are called prefabricated cable. The prefabricated cables are connected to neutron detectors, and installed in the detection holes of the primary shielding tank in the containment vessel. Therefore, at the time of reactor operation, they are exposed to high radiation, and the deterioration of the characteristics of the prefabricated cables is feared. For the purpose of confirming that the part of deteriorating the insulation of the prefabricated cables is connectors, and clarifying the cause of the deterioration of insulation in connector part, the irradiation test of this time was carried out. The environment in which the prefabricated cables are laid, the specifications of the cables and connectors, the materials, gamma ray irradiation and the test results are reported. (K.I.)

  11. Use of forces from instrumented Charpy V-notch testing to determine crack-arrest toughness

    International Nuclear Information System (INIS)

    Iskander, S.K.; Nanstad, R.K.; Sokolov, M.A.; McCabe, D.E.; Hutton, J.T.

    1996-06-01

    The objective of this investigation is an estimation of the crack-arrest toughness, particularly of irradiated materials, from voltage versus time output of an instrumented setup during a test on a Charpy V-notch (CVN) specimen. This voltage versus time trace (which can be converted to force versus displacement) displays events during fracture of the specimen. Various stages of the fracture process can be identified on the trace, including an arrest point indicating arrest of brittle fracture. The force at arrest, F a , versus test temperature, T, relationship is examined to explore possible relationships to other experimental measures of crack-arrest toughness such as the drop-weight nil-ductility temperature (NDT), or crack-arrest toughness, K a . For a wide range of weld and plate materials, the temperature at which F a = 2.45 kN correlates with NDT with a standard deviation, sigma, of about 11 K. Excluding the so-called low upper-shelf energy (USE) welds from the analysis resulted in F a = 4.12 kN and σ = 6.6 K. The estimates of the correlation of the temperature for F a = 7.4 kN with the temperature at 100-MPa√m level for a mean American Society of Mechanical Engineers (ASME) type K Ia curve through crack-arrest toughness values show that prediction of conservative values of K a are possible

  12. ANALYZE THE KNOWLEDGE INQUIRY SCIENCE PHYSICS TEACHER CANDIDATES WITH ESSENCE INQUIRY SCIENCE TEST INSTRUMENT OPTIKA GEOMETRY

    Directory of Open Access Journals (Sweden)

    Wawan Bunawan

    2013-06-01

    Full Text Available The objective in this research to explore the relationship between ability of the knowledge essential features inquiry science and their reasons underlying sense of scientific inquiry for physics teacher candidates on content geometrical optics. The essential features of inquiry science are components that should arise during the learning process subject matter of geometrical optics reflectance of light on a flat mirror, the reflection of light on curved mirrors and refraction of light at the lens. Five of essential features inquiry science adopted from assessment system developed by the National Research Council. Content geometrical optics developed from an analysis of a college syllabus material. Based on the study of the essential features of inquiry and content develop the multiple choice diagnostic test three tier. Data were taken from the students who are taking courses in optics and wave from one the LPTK in North Sumatra totaled 38 students. Instruments showed Cronbach alpha reliability of 0.67 to test the essential features of inquiry science and 0.61 to there as on geometrical optics science inquiry.

  13. Generation of on-line test signals for nuclear instrumentation for PFBR

    International Nuclear Information System (INIS)

    Ram, Rajit; Bhatnagar, P.V.; Rajesh, M.G.; Das, Debashis

    2010-01-01

    Neutron flux monitoring system for PFBR employs pulse signal processing in start up and intermediate power range of reactor operation and Campbell signal processing in intermediate and full power range of reactor operation. Pulse signal processing unit as well as Campbell signal processing unit incorporates FPGA that generates pulse/white noise signal for on-line testing and diagnostic of the channels. In pulse channel fixed/linearly/exponentially varying pulse rate signal is generated over three decades of reactor operation. In the Campbell channel, Poisson distributed noise varying linearly/exponentially is generated over four decades of reactor operation. Multiple numbers of Poisson distributed random pulse trains are summed and amplified to get the white noise signal. Exponentially increasing gain pattern, generated by MATLAB is used to increase the RMS value of the generated noise. The paper discuses the successful testing and validation of pulse and Campbell channel by making use of the generated pulse/white noise signal over wide range of operation for nuclear instrumentation. (author)

  14. Instrumentation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Provides instrumentation support for flight tests of prototype weapons systems using a vast array of airborne sensors, transducers, signal conditioning and encoding...

  15. A Modified Edge Crack Torsion Test for Measurement of Mode III Fracture Toughness of Laminated Tape Composites

    Science.gov (United States)

    Czabaj, Michael W.; Davidson, Barry D.; Ratcliffe, James G.

    2016-01-01

    Modifications to the edge crack torsion (ECT) test are studied to improve the reliability of this test for measuring the mode-III fracture toughness, G (sub IIIc), of laminated tape fiber-reinforced polymeric (FRP) composites. First, the data reduction methods currently used in the ECT test are evaluated and deficiencies in their accuracy are discussed. An alternative data reduction technique, which uses a polynomial form to represent ECT specimen compliance solution, is evaluated and compared to FEA (finite element analysis) results. Second, seven batches of ECT specimens are tested, each batch containing specimens with a preimplanted midplane edge delamination and midplane plies with orientations of plus theta divided by minus theta, with theta ranging from 0 degrees to 90 degrees in 15-degree increments. Tests on these specimens show that intralaminar cracking occurs in specimens from all batches except for which theta = 15 degrees and 30 degrees. Tests on specimens of these two batches are shown to result in mode-III delamination growth at the intended ply interface. The findings from this study are encouraging steps towards the use of the ECT test as a standardized method for measuring G (sub IIIc), although further modification to the data reduction method is required to make it suitable for use as part of a standardized test method.

  16. Development and Testing of Screen-Based and Psychometric Instruments for Assessing Resident Performance in an Operating Room Simulator

    Directory of Open Access Journals (Sweden)

    Richard R. McNeer

    2016-01-01

    Full Text Available Introduction. Medical simulators are used for assessing clinical skills and increasingly for testing hypotheses. We developed and tested an approach for assessing performance in anesthesia residents using screen-based simulation that ensures expert raters remain blinded to subject identity and experimental condition. Methods. Twenty anesthesia residents managed emergencies in an operating room simulator by logging actions through a custom graphical user interface. Two expert raters rated performance based on these entries using custom Global Rating Scale (GRS and Crisis Management Checklist (CMC instruments. Interrater reliability was measured by calculating intraclass correlation coefficients (ICC, and internal consistency of the instruments was assessed with Cronbach’s alpha. Agreement between GRS and CMC was measured using Spearman rank correlation (SRC. Results. Interrater agreement (GRS: ICC = 0.825, CMC: ICC = 0.878 and internal consistency (GRS: alpha = 0.838, CMC: alpha = 0.886 were good for both instruments. Subscale analysis indicated that several instrument items can be discarded. GRS and CMC scores were highly correlated (SRC = 0.948. Conclusions. In this pilot study, we demonstrated that screen-based simulation can allow blinded assessment of performance. GRS and CMC instruments demonstrated good rater agreement and internal consistency. We plan to further test construct validity of our instruments by measuring performance in our simulator as a function of training level.

  17. NASA SMD Airborne Science Capabilities for Development and Testing of New Instruments

    Science.gov (United States)

    Fladeland, Matthew

    2015-01-01

    The SMD NASA Airborne Science Program operates and maintains a fleet of highly modified aircraft to support instrument development, satellite instrument calibration, data product validation and earth science process studies. This poster will provide an overview of aircraft available to NASA researchers including performance specifications and modifications for instrument support, processes for requesting aircraft time and developing cost estimates for proposals, and policies and procedures required to ensure safety of flight.

  18. Waste retrieval sluicing system vapor sampling and analysis plan for evaluation of organic emissions, process test phase III

    International Nuclear Information System (INIS)

    SASAKI, L.M.

    1999-01-01

    This sampling and analysis plan identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained to address vapor issues related to the sluicing of tank 241-C-106. Sampling will be performed in accordance with Waste Retrieval Sluicing System Emissions Collection Phase III (Jones 1999) and Process Test Plan Phase III, Waste Retrieval Sluicing System Emissions Collection (Powers 1999). Analytical requirements include those specified in Request for Ecology Concurrence on Draft Strategy/Path Forward to Address Concerns Regarding Organic Emissions from C-106 Sluicing Activities (Peterson 1998). The Waste Retrieval Sluicing System was installed to retrieve and transfer high-heat sludge from tank 241-C-106 to tank 241-AY-102, which is designed for high-heat waste storage. During initial sluicing of tank 241-C-106 in November 1998, operations were halted due to detection of unexpected high volatile organic compounds in emissions that exceeded regulatory permit limits. Several workers also reported smelling sharp odors and throat irritation. Vapor grab samples from the 296-C-006 ventilation system were taken as soon as possible after detection; the analyses indicated that volatile and semi-volatile organic compounds were present. In December 1998, a process test (phase I) was conducted in which the pumps in tanks 241-C-106 and 241-AY-102 were operated and vapor samples obtained to determine constituents that may be present during active sluicing of tank 241-C-106. The process test was suspended when a jumper leak was detected. On March 7, 1999, phase I1 of the process test was performed; the sluicing system was operated for approximately 7 hours and was ended using the controlled shutdown method when the allowable amount of solids were transferred to 241-AY-102. The phase II test was successful, however, further testing is required to obtain vapor samples at higher emission levels

  19. Adaptation and testing of psychosocial assessment instruments for cross-cultural use: an example from the Thailand Burma border.

    Science.gov (United States)

    Haroz, Emily E; Bass, Judith K; Lee, Catherine; Murray, Laura K; Robinson, Courtland; Bolton, Paul

    2014-01-01

    The purpose of this study was to develop valid and reliable instruments to assess priority psychosocial problems and functioning among adult survivors of systematic violence from Burma living in Thailand. The process involved four steps: 1) instrument drafting and piloting; 2) reliability and validity testing; 3) instrument revision; and 4) retesting revised instrument. A total of N = 158 interviews were completed. Overall subscales showed good internal consistency (0.73-0.92) and satisfactory combined test-retest/inter rater reliability (0.63-0.84). Criterion validity, was not demonstrated for any scale. The alcohol and functioning scales underperformed and were revised (step 3) and retested (step 4). Upon retesting, the function scale showed good internal consistency reliability (0.91-0.92), and the alcohol scale showed acceptable internal consistency (0.79) and strong test-retest/inter-rater reliability (0.86-0.89). This paper describes the importance and process of adaptation and testing, illustrated by the experiences and results for selected instruments in this population.

  20. Mimicking Mars: A vacuum simulation chamber for testing environmental instrumentation for Mars exploration

    Energy Technology Data Exchange (ETDEWEB)

    Sobrado, J. M., E-mail: sobradovj@inta.es; Martín-Soler, J. [Centro de Astrobiología (CAB), INTA-CSIC, Torrejón de Ardoz, 28850 Madrid (Spain); Martín-Gago, J. A. [Centro de Astrobiología (CAB), INTA-CSIC, Torrejón de Ardoz, 28850 Madrid (Spain); Instituto de Ciencias de Materiales de Madrid (ICMM-CSIC), Cantoblanco, 28049 Madrid (Spain)

    2014-03-15

    We have built a Mars environmental simulation chamber, designed to test new electromechanical devices and instruments that could be used in space missions. We have developed this environmental system aiming at validating the meteorological station Rover Environment Monitoring Station of NASA's Mars Science Laboratory mission currently installed on Curiosity rover. The vacuum chamber has been built following a modular configuration and operates at pressures ranging from 1000 to 10{sup −6} mbars, and it is possible to control the gas composition (the atmosphere) within this pressure range. The device (or sample) under study can be irradiated by an ultraviolet source and its temperature can be controlled in the range from 108 to 423 K. As an important improvement with respect to other simulation chambers, the atmospheric gas into the experimental chamber is cooled at the walls by the use of liquid-nitrogen heat exchangers. This chamber incorporates a dust generation mechanism designed to study Martian-dust deposition while modifying the conditions of temperature, and UV irradiated.

  1. Characteristics of X ray calibration fields for performance test of radiation measuring instruments

    International Nuclear Information System (INIS)

    Shimizu, Shigeru; Takahashi, Fumiaki; Sawahata, Tadahiro; Tohnami, Kohichi; Kikuchi, Hiroshi; Murayama, Takashi

    1999-02-01

    Performance test and calibration of the radiation measuring instruments for low energy photons are made using the X ray calibration fields which are monochromatically characterized by filtration of continuous X ray spectrum. The X ray calibration field needs to be characterized by some quality conditions such as quality index and homogeneity coefficient. The present report describes quality conditions, spectrum and some characteristics of X ray irradiation fields in the Facility of Radiation Standard of the Japan Atomic Energy Research Institute (FRS-JAERI). Fifty nine X ray qualities with the quality index of 0.6, 0.7, 0.8 and 0.9 were set for the tube voltages between 10 kV and 350 kV. Estimation of X ray spectrum measured with a Ge detector was made in terms of exposure, ambient dose equivalent and fluence for all the obtained qualities. Practical irradiation field was determined as the dose distribution uniformity is within ±3%. The obtained results improve the quality of X ray calibration fields and calibration accuracy. (author)

  2. Mimicking Mars: a vacuum simulation chamber for testing environmental instrumentation for Mars exploration.

    Science.gov (United States)

    Sobrado, J M; Martín-Soler, J; Martín-Gago, J A

    2014-03-01

    We have built a Mars environmental simulation chamber, designed to test new electromechanical devices and instruments that could be used in space missions. We have developed this environmental system aiming at validating the meteorological station Rover Environment Monitoring Station of NASA's Mars Science Laboratory mission currently installed on Curiosity rover. The vacuum chamber has been built following a modular configuration and operates at pressures ranging from 1000 to 10(-6) mbars, and it is possible to control the gas composition (the atmosphere) within this pressure range. The device (or sample) under study can be irradiated by an ultraviolet source and its temperature can be controlled in the range from 108 to 423 K. As an important improvement with respect to other simulation chambers, the atmospheric gas into the experimental chamber is cooled at the walls by the use of liquid-nitrogen heat exchangers. This chamber incorporates a dust generation mechanism designed to study Martian-dust deposition while modifying the conditions of temperature, and UV irradiated.

  3. A modification design and adjusting test for instruments and control system of critical assembly

    International Nuclear Information System (INIS)

    Wu Manrong; Li Guangjian

    1996-12-01

    A more reliable and safe control system and it's instruments for HFETRCA (high flux engineering test reactor critical assembly) have been built. In the system high performance CMOS unit was used, which has high integration, strong anti-interference and high trigger threshold. In the design of control rod driving circuit, the speed negative feedback principle was applied that results in more stable rotating rate of motors of transmission mechanism and more flexibility of adjusting rod speed. In order to improve reactor safety in accident, additional control circuit is equipped, by which not only control rods with electromagnet will rapidly drop but also other control rods will insert at the speed of 2∼6 times faster than the normal inserting speed. The key technique in the adjustment and new method of anti-interference are also introduced. After more than 40 times physical experiments with (4 x 4 - 4) fuel element in HFETRC, it is proved that the design and adjustment of the system is successful and they can be used as a reference to others. (3 figs., 2 tabs.)

  4. Food-related lifestyles in Singapore: Testing a Western European research instrument in Southeast Asia

    DEFF Research Database (Denmark)

    Askegaard, Søren; Brunsø, Karen; Crippen, Kaye

    The food-realaed life style instrument developed by the MAPP research group has, up till now, been applied mainly in the context of European cultures. The purpose of the present study is to apply the food-related life style instrument in a new and different cultural setting, to compare results, a...

  5. Compilation of three-dimensional coordinates and specific data of the instrumentation of the prestressed concrete pressure vessel/high temperature helium test rig

    International Nuclear Information System (INIS)

    Klausinger, D.

    1977-04-01

    The positions of the thermoelements, strain gauges of various types, and of Gloetzl instruments installed by SGAE in the model vessel of the Common Project Prestressed Concrete Pressure Vessel/High Temperature Helium Test Rig are defined in cylindrical coordinates. The specific data of the instruments are given like configuration of multiple instruments; type, group and number of the instrument; number of cable and of channel; calibration factors; resistances of instruments and cables. (author)

  6. Geotechnical instrumentation requirements for at-depth testing and repository monitoring in tuff

    International Nuclear Information System (INIS)

    Zimmerman, R.M.

    1982-01-01

    Minimum required geotechnical measurements for confirmation of repository performance include thermal and thermomechanical responses; changes in stress, strain, and displacements; and pore pressure and groundwater flow characteristics. Conditions expected in tuff are: maximum rock temperatures of less than 250 0 C, stresses less than 100 MPa, strains between +-0.01 mm/mm, and pore pressures less than 35 KPa in the unsaturated zone where hydraulic head is not the primary contributor. The paper describes instrumentation needed to make the desired measurements. In general, the instrumentation and data system are required to be stable and reliable for tens of years. Designs must consider requirements for temperature stability, temperature expansion compensation, moisture resistance, and long-term durability in mining-type environments. Severe requirements such as these suggest consideration of techniques for in-situ replacement of instrumentation. State-of-the-art instrumentation is briefly described along with a discussion of needs for refinement, replacement/recalibration and instrumentation development

  7. Standard guide for evaluating performance characteristics of phased-Array ultrasonic testing instruments and systems

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide describes procedures for evaluating some performance characteristics of phased-array ultrasonic examination instruments and systems. 1.2 Evaluation of these characteristics is intended to be used for comparing instruments and systems or, by periodic repetition, for detecting long-term changes in the characteristics of a given instrument or system that may be indicative of impending failure, and which, if beyond certain limits, will require corrective maintenance. Instrument characteristics measured in accordance with this guide are expressed in terms that relate to their potential usefulness for ultrasonic examinations. Other electronic instrument characteristics in phased-array units are similar to non-phased-array units and may be measured as described in E 1065 or E 1324. 1.3 Ultrasonic examination systems using pulsed-wave trains and A-scan presentation (rf or video) may be evaluated. 1.4 This guide establishes no performance limits for examination systems; if such acceptance criteria ar...

  8. On the validity of Ksub(Id)-measurements in instrumented impact tests

    International Nuclear Information System (INIS)

    Kalthoff, J.F.; Winkler, S.; Klemm, W.; Beinert, J.

    1979-01-01

    The influence of inertia effects in determining the dynamic fracture toughness Ksub(Id) by instrumented impact testing is investigated. Model experiments in the brittle fracture regime are carried out with precracked bend specimens machined from the epoxy resin Araldite B. As is usual in these tests, the loads at the tup of the impinging striker are recorded as a function of time during the impact process. For reference purposes, the dynamic fracture toughness value Ksub(Id)sup(m1) is derived from the measured maximum load utilizing static stress intensity factor formulas. In addition to this conventional procedure, the actual stress intensity factors are measured directly at the tip of the crack by means of the shadow optical method of caustics applied in combination with high speed photography. The critical value of these optically measured stress intensity factors (for onset of crack propagation), Ksub(Id)sup(opt), is the true dynamic fracture toughness. In the experiments, the specimen size and the impact velocity were varied. In accordance with expectations, it is found that the hammer load signal is not correlated with the actual crack tip stress intensity factor values by a simple proportionality. The conventionally determined Ksub(Id)sup(m1)-value overestimates the true dynamic fracture toughness Ksub(Id)sup(opt). This overestimation becomes larger for larger specimen sizes and larger impact velocities. The results demonstrate the dominating influence inertia effects can have on hammer load measurements and emphasize the importance of eliminating these effects in order to determine non-erroneous dynamic fracture toughness values. (orig.)

  9. Moessbauer/XRF MIMOS Instrumentation and Operation During the 2012 Analog Field Test on Mauna Kea Volcano, Hawaii

    Science.gov (United States)

    Graff, Trevor G.; Morris, R. V.; Klingelhofer, G.; Blumers, M.

    2013-01-01

    Field testing and scientific investigations were conducted on the Mauna Kea Volcano, Hawaii, as part of the 2012 Moon and Mars Analog Mission Activities (MMAMA). Measurements were conducted using both stand-alone and rover-mounted instruments to determine the geophysical and geochemical properties of the field site, as well as provide operational constraints and science considerations for future robotic and human missions [1]. Reported here are the results from the two MIMOS instruments deployed as part of this planetary analog field test.

  10. Instrumental intelligent test of food sensory quality as mimic of human panel test combining multiple cross-perception sensors and data fusion.

    Science.gov (United States)

    Ouyang, Qin; Zhao, Jiewen; Chen, Quansheng

    2014-09-02

    Instrumental test of food quality using perception sensors instead of human panel test is attracting massive attention recently. A novel cross-perception multi-sensors data fusion imitating multiple mammal perception was proposed for the instrumental test in this work. First, three mimic sensors of electronic eye, electronic nose and electronic tongue were used in sequence for data acquisition of rice wine samples. Then all data from the three different sensors were preprocessed and merged. Next, three cross-perception variables i.e., color, aroma and taste, were constructed using principal components analysis (PCA) and multiple linear regression (MLR) which were used as the input of models. MLR, back-propagation artificial neural network (BPANN) and support vector machine (SVM) were comparatively used for modeling, and the instrumental test was achieved for the comprehensive quality of samples. Results showed the proposed cross-perception multi-sensors data fusion presented obvious superiority to the traditional data fusion methodologies, also achieved a high correlation coefficient (>90%) with the human panel test results. This work demonstrated that the instrumental test based on the cross-perception multi-sensors data fusion can actually mimic the human test behavior, therefore is of great significance to ensure the quality of products and decrease the loss of the manufacturers. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. BWR 200 % recirculation pump suction line break LOCA tests, RUNs 942 and 943 at ROSA-III without HPCS

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Tasaka, Kanji; Anoda, Yoshinari; Kumamaru, Hiroshige; Nakamura, Hideo; Yonomoto, Taisuke; Murata, Hideo; Koizumi, Yasuo

    1986-03-01

    This report presents the experimental results of RUNs 942 and 943 in ROSA-III program, which are 200 % recirculation pump suction line break LOCA tests with assumption of HPCS failure. The ROSA-III test facility simulates a BWR system with volume scale of 1/424 and has four half-length electrically heated fuel bundles, two active recirculation loops, ECCS's, and steam and feedwater systems. Effects of initial core void distribution and other fluid conditions on overall LOCA phenomena with special interest on transient core cooling phenomena were investigated by comparing the present test results with those of RUN 926, a 200 % suction line break test with standard initial fluid conditions. The initial core outlet quality was changed between 5 % and 43 %. As conclusions, (1) the initial lower core flow and higher void fraction affected significantly the core cooling conditions and resulted in earlier and higher PCT. (2) The lower plenum flashing temporarily contributed to cool down the core. (3) Flashing of remained hot water in the feedwater line affected slightly the pressure response and delayed the actuation of LPCI by 11 seconds. (4) The whole core was completely cooled down within 104 seconds after the LPCI actuation in these large break tests. (author)

  12. Shock Isolation Elements Testing for High Input Loadings. Volume III. Mechanical Shock Isolation Elements.

    Science.gov (United States)

    SHOCK ABSORBERS ), (*GUIDED MISSILE SILOS, SHOCK ABSORBERS ), (*SPRINGS, (*SHOCK(MECHANICS), REDUCTION), TORSION BARS, ELASTOMERS, DAMPING, EQUATIONS OF MOTION, MODEL TESTS, TEST METHODS, NUCLEAR EXPLOSIONS, HARDENING.

  13. BWR recirculation loop discharge line break LOCA tests with break areas of 50 and 100% assuming HPCS failure at ROSA-III test facility

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Tasaka, Kanji; Yonomoto, Taisuke; Anoda, Yoshinari; Kumamaru, Hiroshige; Nakamura, Hideo; Murata, Hideo; Shiba, Masayoshi; Iriko, Masanori.

    1985-03-01

    This report presents the experimental results of RUN 962 and RUN 963 in ROSA-III program, which are 50 and 100 % break LOCA tests at the BWR recirculation pump discharge line, respectively. The ROSA-III test facility simulates a volumetrically scaled (1/424) BWR system and has four half-length electrically heated fuel bundles, two active recirculation loops, three types of ECCSs and steam and feedwater systems. The experimental data of RUN 962 and RUN 963 were compared with those of RUN 961, a 200 % discharge line break test to study the break area effects on the transient thermal hydraulic phenomena. The least flow areas at the jet pump drive nozzles and recirculation pump discharge nozzle in the broken recirculation loop limitted the discharge flows from the pressure vessel and the depressurization rate in the 100 and 200 % break tests, whereas the least flow area at break nozzle limitted the depressurization rate in the 50 % break test. The highest PCT was observed in the 50 % break test among the three tests. (author)

  14. A New Instrument for Testing Wind Erosion by Soil Surface Shape Change

    International Nuclear Information System (INIS)

    Hai, C.; Yuan, X.; Jiang, H.; Zhou, R.; Wang, J.; Liu, B.; Ye, Y.; Du, P.

    2010-01-01

    Wind erosion, a primary cause of soil degeneration, is a problem in arid and semiarid areas throughout the world. Many methods are available to study soil erosion, but there is no an effective method for making quantitative measurements in the field. To solve this problem, we have developed a new instrument that can measure the change in the shape of the soil surface, allowing quick quantification of wind erosion. In this paper, the construction and principle of the new instrument are described. Field experiments are carried out using the instrument, and the data are analyzed. The erosion depth is found to vary by 11% compared to the average for measurement areas ranging from 30 x 30 cm 2 to 10 x 10 cm 2 . The results show that the instrument is convenient and reliable for quantitatively measuring wind erosion in the field.

  15. A study on the development of instrumented capsule for the material irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hwan; Park, J M; Choo, K N; Maeng, W Y; Park, D K; Oh, J M; Park, S J; Jung, S H; Park, J S; Kim, T R; Park, J H; Yang, S Y; Jun, Y K; Yang, S H

    1997-08-01

    Extensive efforts have been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO`s characteristics. (author). 86 refs., 45 tabs., 146 figs.

  16. An Analysis of the Organizational Structure of Redstone Test Centers Environmental and Components Test Directorate With Regard to Instrumentation Design Capabilities

    Science.gov (United States)

    2016-09-01

    to being the cause of them, resulting in increased absenteeism , lower productivity and grievances and so on” (Raina, 2010). And indeed, General...has on their equipment as well as the system under test. RTC is a test organization, and the end product of each test is data. These engineers design...analyze the data needed to create RTC’s end product . Currently, there are instrumentation groups throughout each of RTC’s directorates. AFTD has a

  17. Product analysis and initial reliability testing of the total mesorectal excision-quality assessment instrument.

    Science.gov (United States)

    Simunovic, Marko R; DeNardi, Franco G; Coates, Angela J; Szalay, David A; Eva, Kevin W

    2014-07-01

    Product analysis of rectal cancer resection specimens before specimen fixation may provide an immediate and relevant evaluation of surgical performance. We tested the interrater reliability (IRR) of a product analysis tool called the Total Mesorectal Excision-Quality Assessment Instrument (TME-QA). Participants included two gold standard raters, five pathology assistants, and eight pathologists. Domains of the TME-QA reflect total mesorectal excision principles including: (1) completeness of mesorectal margin; (2) completeness of mesorectum; (3) coning of distal mesorectum; (4) physical defects; and (5) overall specimen quality. Specimens were scored independently. We used the generalizability theory to assess the tool's internal consistency and IRR. There were 39 specimens and 120 ratings. Mean overall specimen quality scores for the gold standard raters, pathologists, and assistants were 4.43, 4.43, and 4.50, respectively (p > 0.85). IRR for the first nine items was 0.68 for the full sample, 0.62 for assistants alone, 0.63 for pathologists alone, and 0.74 for gold standard raters alone. IRR for the item overall specimen quality was 0.67 for the full sample, 0.45 for assistants, 0.80 for pathologists, and 0.86 for gold standard raters. IRR increased for all groups when scores were averaged across two raters. Assessment of surgical specimens using the TME-QA may provide rapid and relevant feedback to surgeons about their technical performance. Our results show good internal consistency and IRR when the TME-QA is used by pathologists. However, for pathology assistants, multiple ratings with the averaging of scores may be needed.

  18. Testing Commodities as Safe Haven and Hedging Instrument on ASEAN's Five Stock Markets

    OpenAIRE

    Robiyanto, Robiyanto

    2017-01-01

    This study attempts to analyze commodity market instruments such as gold, silver, platinum, palladium, and West Texas Intermediate (WTI) crude oil’s potential as hedge and safe haven toward some stock markets in South East Asia such as in Indonesia, Singapore, Malaysia, Philippines, and Thailand. To analyze the data, GARCH (1,1) was applied. The research findings showed that gold, silver, platinum, palladium, and WTI could not play their role as hedging instrument for five South East Asi...

  19. Designing, Testing, and Validating an Attitudinal Survey on an Environmental Topic: A Groundwater Pollution Survey Instrument for Secondary School Students

    Science.gov (United States)

    Lacosta-Gabari, Idoya; Fernandez-Manzanal, Rosario; Sanchez-Gonzalez, Dolores

    2009-01-01

    Research in environmental attitudes' assessment has significantly increased in recent years. The development of specific attitude scales for specific environmental problems has often been proposed. This paper describes the Groundwater Pollution Test (GPT), a 19-item survey instrument using a Likert-type scale. The survey has been used with…

  20. Intercomparison of active, passive and continuous instruments for radon and radon progeny measurements in the EML chamber and test facility

    International Nuclear Information System (INIS)

    George, A.C.; Knutson, E.O.; Tu, K.W.; Fisenne, I.M.

    1995-12-01

    The results from the May 1995 Intercomparison of Active, Passive and Continuous Instruments for Radon and Radon Progeny Measurement conducted in the EML radon exposure and test facility are presented. Represented were 13 participants that measure radon with open faced and diffusion barrier activated carbon collectors, 10 with nuclear alpha track detectors, 9 with short-term and long-term electret/ionization chambers, and 13 with active and passive commercial electronic continuous monitors. For radon progeny, there were four participants that came in person to take part in the grab sampling methodology for measuring individual radon progeny and the potential alpha energy concentration (PAEC). There were 11 participants with continuous and integrating commercial electronic instruments that are used for measuring the PAEC. The results indicate that all the tested instruments that measure radon fulfill their intended purpose. All instruments and methods used for grab sampling for radon progeny did very well. However, most of the continuous and integrating electronic instruments used for measuring the PAEC or working level appear to underestimate the potential risk from radon progeny when the concentration of particles onto which the radon progeny are attached is -3

  1. Generation of Long-time Complex Signals for Testing the Instruments for Detection of Voltage Quality Disturbances

    Science.gov (United States)

    Živanović, Dragan; Simić, Milan; Kokolanski, Zivko; Denić, Dragan; Dimcev, Vladimir

    2018-04-01

    Software supported procedure for generation of long-time complex test sentences, suitable for testing the instruments for detection of standard voltage quality (VQ) disturbances is presented in this paper. This solution for test signal generation includes significant improvements of computer-based signal generator presented and described in the previously published paper [1]. The generator is based on virtual instrumentation software for defining the basic signal parameters, data acquisition card NI 6343, and power amplifier for amplification of output voltage level to the nominal RMS voltage value of 230 V. Definition of basic signal parameters in LabVIEW application software is supported using Script files, which allows simple repetition of specific test signals and combination of more different test sequences in the complex composite test waveform. The basic advantage of this generator compared to the similar solutions for signal generation is the possibility for long-time test sequence generation according to predefined complex test scenarios, including various combinations of VQ disturbances defined in accordance with the European standard EN50160. Experimental verification of the presented signal generator capability is performed by testing the commercial power quality analyzer Fluke 435 Series II. In this paper are shown some characteristic complex test signals with various disturbances and logged data obtained from the tested power quality analyzer.

  2. Validity of FAA-approved color vision tests for class II and class III aeromedical screening.

    Science.gov (United States)

    1993-09-01

    All clinical color vision tests currently used in the medical examination of pilots were studied regarding validity for prediction of performance on practical tests of ability to discriminate the aviation signal colors, red, green, and white given un...

  3. Initial development and psychometric testing of an instrument to measure the quality of children's end-of-life care.

    Science.gov (United States)

    Widger, Kimberley; Tourangeau, Ann E; Steele, Rose; Streiner, David L

    2015-01-01

    The field of pediatric palliative care is hindered by the lack of a well-defined, reliable, and valid method for measuring the quality of end-of-life care. The study purpose was to develop and test an instrument to measure mothers' perspectives on the quality of care received before, at the time of, and following a child's death. In Phase 1, key components of quality end-of-life care for children were synthesized through a comprehensive review of research literature. These key components were validated in Phase 2 and then extended through focus groups with bereaved parents. In Phase 3, items were developed to assess structures, processes, and outcomes of quality end-of-life care then tested for content and face validity with health professionals. Cognitive testing was conducted through interviews with bereaved parents. In Phase 4, bereaved mothers were recruited through 10 children's hospitals/hospices in Canada to complete the instrument, and psychometric testing was conducted. Following review of 67 manuscripts and 3 focus groups with 10 parents, 141 items were initially developed. The overall content validity index for these items was 0.84 as rated by 7 health professionals. Based on feedback from health professionals and cognitive testing with 6 parents, a 144-item instrument was finalized for further testing. In Phase 4, 128 mothers completed the instrument, 31 of whom completed it twice. Test-retest reliability, internal consistency, and construct validity were demonstrated for six subscales: Connect With Families, Involve Parents, Share Information With Parents, Share Information Among Health Professionals, Support Parents, and Provide Care at Death. Additional items with content validity were grouped in four domains: Support the Child, Support Siblings, Provide Bereavement Follow-up, and Structures of Care. Forty-eight items were deleted through psychometric testing, leaving a 95-item instrument. There is good initial evidence for the reliability and

  4. Modeling of Highly Instrumented Honeywell Turbofan Engine Tested with Ice Crystal Ingestion in the NASA Propulsion System Laboratory

    Science.gov (United States)

    Veres, Joseph P.; Jorgenson, Philip C. E.; Jones, Scott M.

    2016-01-01

    The Propulsion Systems Laboratory (PSL), an altitude test facility at NASA Glenn Research Center, has been used to test a highly instrumented turbine engine at simulated altitude operating conditions. This is a continuation of the PSL testing that successfully duplicated the icing events that were experienced in a previous engine (serial LF01) during flight through ice crystal clouds, which was the first turbofan engine tested in PSL. This second model of the ALF502R-5A serial number LF11 is a highly instrumented version of the previous engine. The PSL facility provides a continuous cloud of ice crystals with controlled characteristics of size and concentration, which are ingested by the engine during operation at simulated altitudes. Several of the previous operating points tested in the LF01 engine were duplicated to confirm repeatability in LF11. The instrumentation included video cameras to visually illustrate the accretion of ice in the low pressure compressor (LPC) exit guide vane region in order to confirm the ice accretion, which was suspected during the testing of the LF01. Traditional instrumentation included static pressure taps in the low pressure compressor inner and outer flow path walls, as well as total pressure and temperature rakes in the low pressure compressor region. The test data was utilized to determine the losses and blockages due to accretion in the exit guide vane region of the LPC. Multiple data points were analyzed with the Honeywell Customer Deck. A full engine roll back point was modeled with the Numerical Propulsion System Simulation (NPSS) code. The mean line compressor flow analysis code with ice crystal modeling was utilized to estimate the parameters that indicate the risk of accretion, as well as to estimate the degree of blockage and losses caused by accretion during a full engine roll back point. The analysis provided additional validation of the icing risk parameters within the LPC, as well as the creation of models for

  5. Assessing contaminant sensitivity of endangered and threatened aquatic species: Part III. Effluent toxicity tests

    Science.gov (United States)

    Dwyer, F.J.; Hardesty, D.K.; Henke, C.E.; Ingersoll, C.G.; Whites, D.W.; Augspurger, T.; Canfield, T.J.; Mount, D.R.; Mayer, F.L.

    2005-01-01

    Toxicity tests using standard effluent test procedures described by the U.S. Environmental Protection Agency were conducted with Ceriodaphnia dubia, fathead minnows (Pimephales promelas), and seven threatened and endangered (listed) fish species from four families: (1) Acipenseridae: shortnose sturgeon (Acipenser brevirostrum); (2) Catostomidae; razorback sucker (Xyrauchen texanus); (3) Cyprinidae: bonytail chub (Gila elegans), Cape Fear shiner (Notropis mekistocholas) Colorado pikeminnow (Ptychocheilus lucius), and spotfin chub (Cyprinella monacha); and (4) Poecillidae: Gila topminnow (Poeciliopsis occidentalis). We conducted 7-day survival and growth studies with embryo-larval fathead minnows and analogous exposures using the listed species. Survival and reproduction were also determined with C. dubia. Tests were conducted with carbaryl, ammonia-or a simulated effluent complex mixture of carbaryl, copper, 4-nonylphenol, pentachlorophenol and permethrin at equitoxic proportions. In addition, Cape Fear shiners and spotfin chub were tested using diazinon, copper, and chlorine. Toxicity tests were also conducted with field-collected effluents from domestic or industrial facilities. Bonytail chub and razorback suckers were tested with effluents collected in Arizona whereas effluent samples collected from North Carolina were tested with Cape Fear shiner, spotfin chub, and shortnose sturgeon. The fathead minnow 7-day effluent test was often a reliable estimator of toxic effects to the listed fishes. However, in 21 % of the tests, a listed species was more sensitive than fathead minnows. More sensitive species results varied by test so that usually no species was always more or less sensitive than fathead minnows. Only the Gila topminnow was consistently less sensitive than the fathead minnow. Listed fish species were protected 96% of the time when results for both fathead minnows and C. dubia were considered, thus reinforcing the value of standard whole

  6. GALEN skin test study III: Minimum battery of test inhalent allergens needed in epidemiological studies in patients

    NARCIS (Netherlands)

    Bousquet, P.-J.; Burbach, G.; Heinzerling, L. M.; Edenharter, G.; Bachert, C.; Bindslev-Jensen, C.; Bonini, S.; Bousquet-Rouanet, L.; Demoly, P.; Bresciani, M.; Bruno, A.; Gjomarkaj, M.; Canonica, G. W.; Darsow, U.; Durham, S.; Fokkens, W. J.; Giavi, S.; Gramiccioni, C.; Papadopoulos, N. G.; Haahtela, T.; Kowalski, M. L.; Magyar, P.; Muraközi, G.; Orosz, M.; Röhnelt, C.; Stingl, G.; Todo-Bom, A.; von Mutius, E.; Wiesner, A.; Wöhrl, S.; Bousquet, J.; Zuberbier, T.

    2009-01-01

    Background: The number of allergens to be tested in order to identify sensitized patients is important in order to have the most cost-effective approach in epidemiological studies. Objective: To define the minimal number and the type of skin prick test (SPT) allergens required to identify a patient

  7. Instrumentation Report No. 2: identification, evaluation, and remedial actions related to transducer failures at the spent fuel test-climax

    Energy Technology Data Exchange (ETDEWEB)

    Patrick, W.C.; Carlson, R.C.; Rector, N.L.

    1981-11-30

    The Spent Fuel Test-Climax (SFT-C) is a test of the feasibility of safe and reliable short-term storage and retrieval of spent fuel from commercial nuclear reactors. In support of operational and technical goals of the test, about 850 channels of instrumentation have been installed at the SFT-C. Failure of several near-field instruments began less than six months after emplacement of 11 canisters of spent fuel and activation of six thermally similar simulators. The failed units were linear potentiometers (used to make displacement measurements) and vibrating wire stressmeters (used to make change-in-stress measurements). This report discusses the observed problems and remedial actions taken to date.

  8. An Integrated Monitoring System Through 3d Laser Scanner and Traditional Instruments for Load Test on Arch Bridge

    Science.gov (United States)

    Pera, D.; Ferrando, I.

    2017-05-01

    The experimental campaign represents an example of how the careful design of the different test phases and the choice of the needed instrumentation are fundamental aspects to obtain a proper interpretation of the results, for future application on the real structures. Additionally, the present work represents a successful example of a combined monitoring system, integrating the traditional and innovative technical instrumentation for loading tests and geomatics survey techniques. The monitoring system has been designed with the aim of defining the load carrying capacity of a masonry arch bridge scaled model and to test the performances of a new retrofitting method. In particular, two different configuration have been considered: a first one with isolated arch and a second one with gravel fill on the arch.

  9. AN INTEGRATED MONITORING SYSTEM THROUGH 3D LASER SCANNER AND TRADITIONAL INSTRUMENTS FOR LOAD TEST ON ARCH BRIDGE

    Directory of Open Access Journals (Sweden)

    D. Pera

    2017-05-01

    Full Text Available The experimental campaign represents an example of how the careful design of the different test phases and the choice of the needed instrumentation are fundamental aspects to obtain a proper interpretation of the results, for future application on the real structures. Additionally, the present work represents a successful example of a combined monitoring system, integrating the traditional and innovative technical instrumentation for loading tests and geomatics survey techniques. The monitoring system has been designed with the aim of defining the load carrying capacity of a masonry arch bridge scaled model and to test the performances of a new retrofitting method. In particular, two different configuration have been considered: a first one with isolated arch and a second one with gravel fill on the arch.

  10. A Novel Design of Needle Aspiration Biopsy Monitoring Instrument (NAOMI Tested on a Low Cost Chest Phantom

    Directory of Open Access Journals (Sweden)

    Surakusumah Rino Ferdian

    2016-01-01

    Full Text Available Needle biopsy is a medical intervention method for taking a lung tissue sample that suspected as a cancer. The disadvantage is the physicians directly visualize the anatomical structures in an open surgery for lung cancer biopsy procedure. There is a need to develop an instrument that may help the physician to guarantee the accuracy and efficiency while performing needle aspiration biopsy. Therefore, a needle aspiration biopsy monitoring instrument or named as NAOMI is proposed. It consists of a microcontroller system, an IMU sensor, an ultrasonic ranging module, a bluetooth module, and a 9V lithium battery. The experimental testing consist of performance testing, functional testing using chest phantom, and user acceptances. The results showed that the NAOMI improve the accuracy and efficiency while performing the needle biopsy operation.

  11. Instrumentation Report No. 2: identification, evaluation, and remedial actions related to transducer failures at the spent fuel test-climax

    International Nuclear Information System (INIS)

    Patrick, W.C.; Carlson, R.C.; Rector, N.L.

    1981-01-01

    The Spent Fuel Test-Climax (SFT-C) is a test of the feasibility of safe and reliable short-term storage and retrieval of spent fuel from commercial nuclear reactors. In support of operational and technical goals of the test, about 850 channels of instrumentation have been installed at the SFT-C. Failure of several near-field instruments began less than six months after emplacement of 11 canisters of spent fuel and activation of six thermally similar simulators. The failed units were linear potentiometers (used to make displacement measurements) and vibrating wire stressmeters (used to make change-in-stress measurements). This report discusses the observed problems and remedial actions taken to date

  12. Evaluation report on SCTF Core-III tests S3-7 and S3-8

    International Nuclear Information System (INIS)

    Okubo, Tsutomu; Iguchi, Tadashi; Iwamura, Takamichi

    1990-03-01

    It has been said that the Emergency Core Cooling (ECC) water injected into the hot legs flows into the upper plenum and then falls back to the core (i.e. break-through) during reflood phase in a German type Pressurized Water Reactor (GPWR) with the combined-injection-type ECCS, and that the break-through occurs where the water temperature at the tie plate area is lower and subcooled. Based on this information two tests were conducted with the Slab Core Test Facility (SCTF) Core-III in order to investigate the effects of the water temperature distribution at the tie plate area on the break-through and the core cooling. In these tests, the subcooled ECC water was injected just above the Upper Core Support Plate (UCSP) in order to establish the desired water temperature distribution at the tie plate area. In one test (Test S3-7) the ECC water injection above the UCSP was performed above Bundles 3 and 4, and in the other test (Test S3-8) above Bundles 7 and 8 during initial 60 s a and then was changed to above Bundles 3 and 4. The test data were compared with those of Test S3-SH1, in which the injection was performed above Bundles 7 and 8 and the other test conditions were the same as in Tests S3-7 and S3-8. Analyzing these test data, the following has been found: The break-through occurs where the water temperature at the tie plate area is subcooled and the core cooling is enhanced significantly in the break-through region. The break-through location changes, with some time lag, following the change of the water temperature distribution at the tie plate area. Furthermore, the core cooling in the non-break-through regions is almost the same regardless of the location of the break-through. (author)

  13. Development and testing of a cross-culturally valid instrument: food-related life style

    DEFF Research Database (Denmark)

    Brunsø, Karen; Grunert, Klaus G.

    1995-01-01

    Based on a cognitive perspective, we propose to make life style specific to certain areas of consumption. The specific area of consumption studied here is food, resulting in a concept of food-related life style. We have developed an instrument tha measure food-related life style in a cross...

  14. 77 FR 55217 - Submission for OMB Review; Comment Request: Cognitive Testing of Instrumentation and Materials...

    Science.gov (United States)

    2012-09-07

    ... instrumentation, supporting materials, consent forms, and methods of administration (e.g., computer assisted personal interviews [CAPI], audio computer assisted self- interviews [ACASI], web-based interviews... participation Youth 200 1 1 \\30/60\\ 300 in PATH study. Consent forms for Adult 200 1 1 \\30/60\\ 300 participation...

  15. Use of a personal computer for instrumentation testing at the FFTF

    International Nuclear Information System (INIS)

    Clark, D.A.

    1985-01-01

    The FFTF uses computers to assist in performance of instrumentation calibration checks for Technical Specification compliance. When the computers used for these checks are not available, back-up methods must be used. A method of using a personal computer to serve as a back-up is discussed, and the hardware used is described

  16. 241-SY-101 DACS instrument problem screen (SCR 448) acceptance test procedure

    International Nuclear Information System (INIS)

    ERMI, A.M.

    1999-01-01

    The operability of the 241-SY-101 Data Acquisition and Control System (DACS) to provide proper control and monitoring of the mitigation mixer pump and instrumentation installed in the 241-SY-101 underground storage tank utilizing the [INSTPROB] screen will be systematically evaluated by the performance of this procedure

  17. Predictor Development and Pilot Testing of a Prototype Selection Instrument for Army Flight Training

    Science.gov (United States)

    2007-02-01

    called the Automated Pilot Examination System, or "APEX") during the preliminary validation reserach . The current version of the ASTB includes subtests... methodology described in this report will be used to produce a scientifically sound instrument to predict the likelihood that individuals will successfully

  18. Detection of endotoxins in radiopharmaceutical preparations. III. Limulus test assessment using radiopharmaceutical preparations; correlation with the rabbit pyrogen test

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Y; Bahri, F; Bruneau, J; Dubuis, M; Dubuis, N; Merlin, L; Michaud, T; Peysson, S

    1986-01-01

    Experiments using 17 radiopharmaceuticals containing known amounts of added endotoxin show that none of them inhibits the pyrogenic reaction of the rabbit. Gelation of the Limulus amoebocyte lysate (LAL) is inhibited by 4 of them: colloidal erbium 169Er citrate, colloidal rhenium 186Re sulfide, colloidal technetium /sup 99m/Tc (Re) sulfide for liver scintigraphy and the colloidal technetium /sup 99m/Tc (Re) sulfide for lymphography. This inhibition is cancelled, either by dilution or after neutral pH adjustment. Both controls were performed on 313 batches of various radiopharmaceuticals, 95% of results were identical (93% negative, 2% positive). The remaining 5% correspond to positive LAL tests vs negative rabbit tests on the same batches. No negative LAL test vs positive rabbit test was observed.

  19. BWR 1 % main recirculation line break LOCA tests, RUNs 917 and 918, without HPCS at ROSA-III program

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Okazaki, Motoaki; Anoda, Yoshinari; Kumamaru, Hiroshige; Nakamura, Hideo; Yonomoto, Taisuke; Koizumi, Yasuo; Tasaka, Kanji

    1988-07-01

    In a case of small break loss-of-coolant accident (LOCA) at a boiling water reactor (BWR) system, it is important to lower the system pressure to cool down the reactor system by using either the high pressure core spray (HPCS) or the automatic depressurization system (ADS). The report presents characteristic test results of RUNs 918 and 917, which were performed at the rig-of-safety assessment (ROSA)-III program simulating a 1 % break BWR LOCA with an assumption of HPCS failure, and clarifies effects of the ADS delay time on a small break LOCA. The ROSA-III test facility simulates principal components of a BWR/6 system with volumetric scaling factor of 1/424. It is experimentally concluded that the ADS delay time shorter than 4 minutes results in a similar PCT as that in a standard case, in which the PCT is observed after actuation of the low pressure core spray (LPCS). And the ADS delay time longer than 4 minutes results in higher PCT than in the standard case. In the latter, the PCT depends on the ADS time, a 220 K higher PCT, for example, in a case of 10 minutes ADS delay compared with the standard case. (author) 52 refs. 299 figs

  20. ITER ECRH Upper Launcher: Test plan for qualification of the Diamond Torus Window Prototype III

    Energy Technology Data Exchange (ETDEWEB)

    Schreck, Sabine, E-mail: sabine.schreck@kit.edu [Karlsruhe Institute of Technology, Institute for Applied Materials, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Aiello, Gaetano; Meier, Andreas; Strauss, Dirk [Karlsruhe Institute of Technology, Institute for Applied Materials, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Gagliardi, Mario; Saibene, Gabriella [F4E, Antennas and Plasma Engineering, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Scherer, Theo [Karlsruhe Institute of Technology, Institute for Applied Materials, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)

    2016-11-01

    Highlights: • A qualification program for the ITER diamond torus window is being developed. • The testing program for the qualification of the bare diamond disk is defined. • First qualification tests show a very good quality of the diamond disk prototypes. - Abstract: The diamond window is part of the electron cyclotron heating upper launcher system for ITER. Together with the isolation valve it constitutes the primary vacuum boundary and it also acts as first tritium barrier. Therefore the window is classified as Safety/Protection Important Component (SIC/PIC) with the nuclear safety function “confinement”. As the diamond window unit is not entirely covered by standard codes, an ad-hoc qualification program needs to be defined, including analysis, prototyping and testing. In the framework of a contract with F4E, the test program for a diamond window prototype is being developed with the aim to prove its operability for normal, accidental and incidental conditions as identified in the ITER load specifications. Tests range from dielectric loss measurements for the bare Chemical Vapour Deposition (CVD) diamond disk up to mechanical and vacuum tests for the complete window assembly. Finally mm-wave properties have to be characterized for the complete window. A clear definition of the testing requirements and of the acceptance criteria is necessary as well as a complete documentation of the process. This paper will present the development of the test plan for a window prototype, which is currently under manufacturing. First tests are directed to the characterization of the bare diamond disk with a focus on its dielectric properties.

  1. Briefer assessment of social network drinking: A test of the Important People Instrument-5 (IP-5).

    Science.gov (United States)

    Hallgren, Kevin A; Barnett, Nancy P

    2016-12-01

    The Important People instrument (IP; Longabaugh et al., 2010) is one of the most commonly used measures of social network drinking. Although its reliability and validity are well-supported, the length of the instrument may limit its use in many settings. The present study evaluated whether a briefer, 5-person version of the IP (IP-5) adequately reproduces scores from the full IP. College freshmen (N = 1,053) reported their own past-month drinking, alcohol-related consequences, and information about drinking in their close social networks at baseline and 1 year later. From this we derived network members' drinking frequency, percentage of drinkers, and percentage of heavy drinkers, assessed for up to 10 (full IP) or 5 (IP-5) network members. We first modeled the expected concordance between full-IP scores and scores from simulated shorter IP instruments by sampling smaller subsets of network members from full IP data. Then, using quasi-experimental methods, we administered the full IP and IP-5 and compared the 2 instruments' score distributions and concurrent and year-lagged associations with participants' alcohol consumption and consequences. Most of the full-IP variance was reproduced from simulated shorter versions of the IP (ICCs ≥ 0.80). The full IP and IP-5 yielded similar score distributions, concurrent associations with drinking (r = 0.22 to 0.52), and year-lagged associations with drinking. The IP-5 retains most of the information about social network drinking from the full IP. The shorter instrument may be useful in clinical and research settings that require frequent measure administration, yielding greater temporal resolution for monitoring social network drinking. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  2. Ethical issues in palliative care for nursing homes: Development and testing of a survey instrument.

    Science.gov (United States)

    Preshaw, Deborah Hl; McLaughlin, Dorry; Brazil, Kevin

    2018-02-01

    To develop and psychometrically assess a survey instrument identifying ethical issues during palliative care provision in nursing homes. Registered nurses and healthcare assistants have reported ethical issues in everyday palliative care provision. Identifying these issues provides evidence to inform practice development to support healthcare workers. Cross-sectional survey of Registered nurses and healthcare assistants in nursing homes in one region of the UK. A survey instrument, "Ethical issues in Palliative Care for Nursing homes", was developed through the findings of qualitative interviews with Registered nurses and healthcare assistants in nursing homes and a literature review. It was reviewed by an expert panel and piloted prior to implementation in a survey in 2015 with a convenience sample of 596 Registered nurses and healthcare assistants. Descriptive and exploratory factor analyses were used to assess the underlying structure of the Frequency and Distress Scales within the instrument. Analysis of 201 responses (response rate = 33.7%) revealed four factors for the Frequency Scale and five factors for the Distress Scale that comprise the Ethical issues in Palliative Care for Nursing homes. Factors common to both scales included "Processes of care," "Resident autonomy" and "Burdensome treatment." Additionally, the Frequency Scale included "Competency," and the Distress Scale included "Quality of care" and "Communication." The Ethical issues in Palliative Care for Nursing homes instrument has added to the palliative care knowledge base by considering the ethical issues experienced specifically by Registered nurses and healthcare assistants within the nursing home. This research offers preliminary evidence of the psychometric properties of the Ethical issues in Palliative Care for Nursing homes survey instrument. The two largest factors highlight the need to address the organisational aspects of caring and provide training in negotiating conflicting

  3. Cyclic Fatigue Testing of Three Different Rotary Nickel Titanium Endodontic Instruments in Simulated Curved Canals - An in Vitro Sem Analysis

    OpenAIRE

    Reddy Y., Pallavi; S., Kavita; Subbarao, C.V.

    2014-01-01

    Introduction: Instrument separation is a serious concern in endodontics. Stainless steel instruments usually deform before they separate whereas Nickel Titanium instruments do not show any sign of deformation.

  4. Development and Preliminary Tests of an Open-Path Airborne Diode Laser Absorption Instrument for Carbon Dioxide

    Science.gov (United States)

    Diskin, Glenn S.; DiGangi, Joshua P.; Yang, Melissa; Slate, Thomas A.; Rana, Mario

    2015-01-01

    Carbon dioxide (CO2) is well known for its importance as an atmospheric greenhouse gas, with many sources and sinks around the globe. Understanding the fluxes of carbon into and out of the atmosphere is a complex and daunting challenge. One tool applied by scientists to measure the vertical flux of CO2 near the surface uses the eddy covariance technique, most often from towers but also from aircraft flying specific patterns over the study area. In this technique, variations of constituents of interest are correlated with fluctuations in the local vertical wind velocity. Measurement requirements are stringent, particularly with regard to precision, sensitivity to small changes, and temporal sampling rate. In addition, many aircraft have limited payload capability, so instrument size, weight, and power consumption are also important considerations. We report on the development and preliminary application of an airborne sensor for the measurement of atmospheric CO2. The instrument, modeled on the successful DLH (Diode Laser Hygrometer) series of instruments, has been tested in the laboratory and on the NASA DC-8 aircraft. Performance parameters such as accuracy, precision, sensitivity, specificity, and temporal response are discussed in the context of typical atmospheric variability and suitability for flux measurement applications. On-aircraft, in-flight data have been obtained and are discussed as well. Performance of the instrument has been promising, and continued flight testing is planned during 2016.

  5. Developing and testing an instrument to measure the presence of conditions for successful implementation of quality improvement collaboratives.

    Science.gov (United States)

    Dückers, Michel L A; Wagner, Cordula; Groenewegen, Peter P

    2008-08-11

    In quality improvement collaboratives (QICs) teams of practitioners from different health care organizations are brought together to systematically improve an aspect of patient care. Teams take part in a series of meetings to learn about relevant best practices, quality methods and change ideas, and share experiences in making changes in their own local setting. The purpose of this study was to develop an instrument for measuring team organization, external change agent support and support from the team's home institution in a Dutch national improvement and dissemination programme for hospitals based on several QICs. The exploratory methodological design included two phases: a) content development and assessment, resulting in an instrument with 15 items, and b) field testing (N = 165). Internal consistency reliability was tested via Cronbach's alpha coefficient. Principal component analyses were used to identify underlying constructs. Tests of scaling assumptions according to the multi trait/multi-item matrix, were used to confirm the component structure. Three components were revealed, explaining 65% of the variability. The components were labelled 'organizational support', 'team organization' and 'external change agent support'. One item not meeting item-scale criteria was removed. This resulted in a 14 item instrument. Scale reliability ranged from 0.77 to 0.91. Internal item consistency and divergent validity were satisfactory. On the whole, the instrument appears to be a promising tool for assessing team organization and internal and external support during QIC implementation. The psychometric properties were good and warrant application of the instrument for the evaluation of the national programme and similar improvement programmes.

  6. Developing and testing an instrument to measure the presence of conditions for successful implementation of quality improvement collaboratives

    Directory of Open Access Journals (Sweden)

    Wagner Cordula

    2008-08-01

    Full Text Available Abstract Background In quality improvement collaboratives (QICs teams of practitioners from different health care organizations are brought together to systematically improve an aspect of patient care. Teams take part in a series of meetings to learn about relevant best practices, quality methods and change ideas, and share experiences in making changes in their own local setting. The purpose of this study was to develop an instrument for measuring team organization, external change agent support and support from the team's home institution in a Dutch national improvement and dissemination programme for hospitals based on several QICs. Methods The exploratory methodological design included two phases: a content development and assessment, resulting in an instrument with 15 items, and b field testing (N = 165. Internal consistency reliability was tested via Cronbach's alpha coefficient. Principal component analyses were used to identify underlying constructs. Tests of scaling assumptions according to the multi trait/multi-item matrix, were used to confirm the component structure. Results Three components were revealed, explaining 65% of the variability. The components were labelled 'organizational support', 'team organization' and 'external change agent support'. One item not meeting item-scale criteria was removed. This resulted in a 14 item instrument. Scale reliability ranged from 0.77 to 0.91. Internal item consistency and divergent validity were satisfactory. Conclusion On the whole, the instrument appears to be a promising tool for assessing team organization and internal and external support during QIC implementation. The psychometric properties were good and warrant application of the instrument for the evaluation of the national programme and similar improvement programmes.

  7. Group of scientific experts third technical test (GSETT-III) experiences

    International Nuclear Information System (INIS)

    Dahlman, O.

    1999-01-01

    The purpose of the established verification system is to provide confidence through adequate monitoring, deter clandestine activities and counteract 'false arms'. The task og the Group of Scientific Experts was to design and test the seismic verification system including designing og the international system, sharing knowledge from national programs, encouraging establishment of new monitoring facilities, development of data analysis procedures, conducting large scale testing and training of experts

  8. Tritium test of the tritium processing components under the Annex III US-Japan Collaboration

    International Nuclear Information System (INIS)

    Konishi, Satoshi; Yoshida, Hiroshi; Naruse, Yuji; Binning, K.E.; Carlson, R.V.; Bartlit, J.R.; Anderson, J.L.

    1993-03-01

    The process ready components for Fuel Cleanup System were tested at the TSTA under the US-Japan Collaboration program. Palladium diffuser for tritium purification and Ceramic Electrolysis Cell for decomposition of tritiated water respectively were tested with pure tritium for years. The characteristics of the components with hydrogen isotopes, effects of impurities, and long-term reliability of the components were studied. It was concluded that these components are suitable and attractive for fusion fuel processing systems. (author)

  9. Standard test method for verifying the alignment of X-Ray diffraction instrumentation for residual stress measurement

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the preparation and use of a flat stress-free test specimen for the purpose of checking the systematic error caused by instrument misalignment or sample positioning in X-ray diffraction residual stress measurement, or both. 1.2 This test method is applicable to apparatus intended for X-ray diffraction macroscopic residual stress measurement in polycrystalline samples employing measurement of a diffraction peak position in the high-back reflection region, and in which the θ, 2θ, and ψ rotation axes can be made to coincide (see Fig. 1). 1.3 This test method describes the use of iron powder which has been investigated in round-robin studies for the purpose of verifying the alignment of instrumentation intended for stress measurement in ferritic or martensitic steels. To verify instrument alignment prior to stress measurement in other metallic alloys and ceramics, powder having the same or lower diffraction angle as the material to be measured should be prepared in similar fashion...

  10. Subsonic Ultra Green Aircraft Research: Phase II- Volume III-Truss Braced Wing Aeroelastic Test Report

    Science.gov (United States)

    Bradley, Marty K.; Allen, Timothy J.; Droney, Christopher

    2014-01-01

    This Test Report summarizes the Truss Braced Wing (TBW) Aeroelastic Test (Task 3.1) work accomplished by the Boeing Subsonic Ultra Green Aircraft Research (SUGAR) team, which includes the time period of February 2012 through June 2014. The team consisted of Boeing Research and Technology, Boeing Commercial Airplanes, Virginia Tech, and NextGen Aeronautics. The model was fabricated by NextGen Aeronautics and designed to meet dynamically scaled requirements from the sized full scale TBW FEM. The test of the dynamically scaled SUGAR TBW half model was broken up into open loop testing in December 2013 and closed loop testing from January 2014 to April 2014. Results showed the flutter mechanism to primarily be a coalescence of 2nd bending mode and 1st torsion mode around 10 Hz, as predicted by analysis. Results also showed significant change in flutter speed as angle of attack was varied. This nonlinear behavior can be explained by including preload and large displacement changes to the structural stiffness and mass matrices in the flutter analysis. Control laws derived from both test system ID and FEM19 state space models were successful in suppressing flutter. The control laws were robust and suppressed flutter for a variety of Mach, dynamic pressures, and angle of attacks investigated.

  11. DECOVALEX III PROJECT. Modelling of FEBEX In-Situ Test. Task1 Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, E.E.; Alcoverro, J. [Univ. Politecnica de Catalunya, Barcelona (Spain)] (comps.)

    2005-02-15

    Task 1 of DECOVALEX III was conceived as a benchmark exercise supported by all field and laboratory data generated during the performance of the FEBEX experiment designed to study thermo-hydro-mechanical and thermo-hydro-geochemical processes of the buffer and rock in the near field. The task was defined as a series of three successive blind prediction exercises (Parts A, B and C), which cover the behaviour of both the rock and bentonite barrier. Research teams participating in the FEBEX task were given, for each of the three parts, a set of field and laboratory data theoretically sufficient to generate a proper model and were asked to submit predictions, at given locations and time, for some of the measured variables. The merits and limitations of different modeling approaches were therefore established. The teams could perform additional calculations, once the actual 'solution' was disclosed. Final calculations represented the best approximation that a given team could provide, always within the general time constraints imposed by the General DECOVALEX III Organization. This report presents the works performed for Task 1. It contains the case definitions and evaluations of modelling results for Part A, B and C, and the overall evaluation of the works performed. The report is completed by a CD-ROM containing a set of final reports provided by the modeling teams participating in each of the three parts defined. These reports provide the necessary details to better understand the nature of the blind or final predictions included in this report. The report closes with a set of conclusions, which provides a summary of the main findings and highlights the lessons learned, some of which were summarized below. The best predictions of the water inflow into the excavated tunnel are found when the hydro geological model is properly calibrated on the basis of other known flow measurements in the same area. The particular idealization of the rock mass (equivalent

  12. DECOVALEX III PROJECT. Modelling of FEBEX In-Situ Test. Task1 Final Report

    International Nuclear Information System (INIS)

    Alonso, E.E.; Alcoverro, J.

    2005-02-01

    Task 1 of DECOVALEX III was conceived as a benchmark exercise supported by all field and laboratory data generated during the performance of the FEBEX experiment designed to study thermo-hydro-mechanical and thermo-hydro-geochemical processes of the buffer and rock in the near field. The task was defined as a series of three successive blind prediction exercises (Parts A, B and C), which cover the behaviour of both the rock and bentonite barrier. Research teams participating in the FEBEX task were given, for each of the three parts, a set of field and laboratory data theoretically sufficient to generate a proper model and were asked to submit predictions, at given locations and time, for some of the measured variables. The merits and limitations of different modeling approaches were therefore established. The teams could perform additional calculations, once the actual 'solution' was disclosed. Final calculations represented the best approximation that a given team could provide, always within the general time constraints imposed by the General DECOVALEX III Organization. This report presents the works performed for Task 1. It contains the case definitions and evaluations of modelling results for Part A, B and C, and the overall evaluation of the works performed. The report is completed by a CD-ROM containing a set of final reports provided by the modeling teams participating in each of the three parts defined. These reports provide the necessary details to better understand the nature of the blind or final predictions included in this report. The report closes with a set of conclusions, which provides a summary of the main findings and highlights the lessons learned, some of which were summarized below. The best predictions of the water inflow into the excavated tunnel are found when the hydro geological model is properly calibrated on the basis of other known flow measurements in the same area. The particular idealization of the rock mass (equivalent porous media

  13. Development and Preliminary Testing of a High Precision Long Stroke Slit Change Mechanism for the SPICE Instrument

    Science.gov (United States)

    Paciotti, Gabriel; Humphries, Martin; Rottmeier, Fabrice; Blecha, Luc

    2014-01-01

    In the frame of ESA's Solar Orbiter scientific mission, Almatech has been selected to design, develop and test the Slit Change Mechanism of the SPICE (SPectral Imaging of the Coronal Environment) instrument. In order to guaranty optical cleanliness level while fulfilling stringent positioning accuracies and repeatability requirements for slit positioning in the optical path of the instrument, a linear guiding system based on a double flexible blade arrangement has been selected. The four different slits to be used for the SPICE instrument resulted in a total stroke of 16.5 mm in this linear slit changer arrangement. The combination of long stroke and high precision positioning requirements has been identified as the main design challenge to be validated through breadboard models testing. This paper presents the development of SPICE's Slit Change Mechanism (SCM) and the two-step validation tests successfully performed on breadboard models of its flexible blade support system. The validation test results have demonstrated the full adequacy of the flexible blade guiding system implemented in SPICE's Slit Change Mechanism in a stand-alone configuration. Further breadboard test results, studying the influence of the compliant connection to the SCM linear actuator on an enhanced flexible guiding system design have shown significant enhancements in the positioning accuracy and repeatability of the selected flexible guiding system. Preliminary evaluation of the linear actuator design, including a detailed tolerance analyses, has shown the suitability of this satellite roller screw based mechanism for the actuation of the tested flexible guiding system and compliant connection. The presented development and preliminary testing of the high-precision long-stroke Slit Change Mechanism for the SPICE Instrument are considered fully successful such that future tests considering the full Slit Change Mechanism can be performed, with the gained confidence, directly on a

  14. Final Report: Part 1. In-Place Filter Testing Instrument for Nuclear Material Containers. Part 2. Canister Filter Test Standards for Aerosol Capture Rates.

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Austin Douglas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Runnels, Joel T. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Moore, Murray E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Reeves, Kirk Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-11-02

    A portable instrument has been developed to assess the functionality of filter sand o-rings on nuclear material storage canisters, without requiring removal of the canister lid. Additionally, a set of fifteen filter standards were procured for verifying aerosol leakage and pressure drop measurements in the Los Alamos Filter Test System. The US Department of Energy uses several thousand canisters for storing nuclear material in different chemical and physical forms. Specialized filters are installed into canister lids to allow gases to escape, and to maintain an internal ambient pressure while containing radioactive contaminants. Diagnosing the condition of container filters and canister integrity is important to ensure worker and public safety and for determining the handling requirements of legacy apparatus. This report describes the In-Place-Filter-Tester, the Instrument Development Plan and the Instrument Operating Method that were developed at the Los Alamos National Laboratory to determine the “as found” condition of unopened storage canisters. The Instrument Operating Method provides instructions for future evaluations of as-found canisters packaged with nuclear material. Customized stainless steel canister interfaces were developed for pressure-port access and to apply a suction clamping force for the interface. These are compatible with selected Hagan-style and SAVY-4000 storage canisters that were purchased from NFT (Nuclear Filter Technology, Golden, CO). Two instruments were developed for this effort: an initial Los Alamos POC (Proof-of-Concept) unit and the final Los Alamos IPFT system. The Los Alamos POC was used to create the Instrument Development Plan: (1) to determine the air flow and pressure characteristics associated with canister filter clogging, and (2) to test simulated configurations that mimicked canister leakage paths. The canister leakage scenarios included quantifying: (A) air leakage due to foreign material (i.e. dust and hair

  15. Rover-Based Instrumentation and Scientific Investigations During the 2012 Analog Field Test on Mauna Kea Volcano, Hawaii

    Science.gov (United States)

    Graham, L. D.; Graff, T. G.

    2013-01-01

    Rover-based 2012 Moon and Mars Analog Mission Activities (MMAMA) were recently completed on Mauna Kea Volcano, Hawaii. Scientific investigations, scientific input, and operational constraints were tested in the context of existing project and protocols for the field activities designed to help NASA achieve the Vision for Space Exploration [1]. Several investigations were conducted by the rover mounted instruments to determine key geophysical and geochemical properties of the site, as well as capture the geological context of the area and the samples investigated. The rover traverse and associated science investigations were conducted over a three day period on the southeast flank of the Mauna Kea Volcano, Hawaii. The test area was at an elevation of 11,500 feet and is known as "Apollo Valley" (Fig. 1). Here we report the integration and operation of the rover-mounted instruments, as well as the scientific investigations that were conducted.

  16. Testing Commodities as Safe Haven and Hedging Instrument on ASEAN's Five Stock Markets

    Directory of Open Access Journals (Sweden)

    Robiyanto Robiyanto

    2017-08-01

    Full Text Available This study attempts to analyze commodity market instruments such as gold, silver, platinum, palladium, and West Texas Intermediate (WTI crude oil’s potential as hedge and safe haven toward some stock markets in South East Asia such as in Indonesia, Singapore, Malaysia, Philippines, and Thailand. To analyze the data, GARCH (1,1 was applied. The research findings showed that gold, silver, platinum, palladium, and WTI could not play their role as hedging instrument for five South East Asian capital markets. WTI could act as a robust safe haven for most South East Asian capital markets. Gold could do the role as a robust safe haven in Singapore and Malaysia, whereas, platinum and silver consistently could be safe haven only for Singapore Stock Exchange. Palladium could only be safe haven for Philippines Stock Exchange.

  17. Instrument Control (iC) – An Open-Source Software to Automate Test Equipment

    Science.gov (United States)

    Pernstich, K. P.

    2012-01-01

    It has become common practice to automate data acquisition from programmable instrumentation, and a range of different software solutions fulfill this task. Many routine measurements require sequential processing of certain tasks, for instance to adjust the temperature of a sample stage, take a measurement, and repeat that cycle for other temperatures. This paper introduces an open-source Java program that processes a series of text-based commands that define the measurement sequence. These commands are in an intuitive format which provides great flexibility and allows quick and easy adaptation to various measurement needs. For each of these commands, the iC-framework calls a corresponding Java method that addresses the specified instrument to perform the desired task. The functionality of iC can be extended with minimal programming effort in Java or Python, and new measurement equipment can be addressed by defining new commands in a text file without any programming. PMID:26900522

  18. Instrument Control (iC) - An Open-Source Software to Automate Test Equipment.

    Science.gov (United States)

    Pernstich, K P

    2012-01-01

    It has become common practice to automate data acquisition from programmable instrumentation, and a range of different software solutions fulfill this task. Many routine measurements require sequential processing of certain tasks, for instance to adjust the temperature of a sample stage, take a measurement, and repeat that cycle for other temperatures. This paper introduces an open-source Java program that processes a series of text-based commands that define the measurement sequence. These commands are in an intuitive format which provides great flexibility and allows quick and easy adaptation to various measurement needs. For each of these commands, the iC-framework calls a corresponding Java method that addresses the specified instrument to perform the desired task. The functionality of iC can be extended with minimal programming effort in Java or Python, and new measurement equipment can be addressed by defining new commands in a text file without any programming.

  19. Fatigue testing of controlled memory wire nickel-titanium rotary instruments.

    Science.gov (United States)

    Shen, Ya; Qian, Wei; Abtin, Houman; Gao, Yuan; Haapasalo, Markus

    2011-07-01

    To improve the fracture resistance of nickel-titanium (NiTi) files, manufacturers have introduced new alloys to manufacture NiTi files and developed new manufacturing processes. This study was aimed to examine the fatigue behavior of NiTi instruments from a novel controlled memory NiTi wire (CM Wire). Instruments of ProFile, Typhoon (TYP), Typhoon CM (TYP CM), DS-SS0250425NEYY (NEYY), and DS-SS0250425NEYY CM (NEYY CM) (DS Dental, Johnson City, TN) all size 25/.04 were subjected to rotational bending at the curvature of 35° and 45° in air at the temperature of 23° ± 2°C, and the number of revolutions to fracture (N(f)) was recorded. The fracture surface of all fragments was examined by a scanning electron microscope. The crack-initiation sites, the percentage of dimple area to the whole fracture cross-section, and the surface strain amplitude (ε(a)) were noted. The new alloy yielded an improvement of over three to eight times in N(f) of CM files than that of conventional NiTi files (P wire (58%-100%) had one crack origin. The values of the fraction area occupied by the dimple region were significantly smaller on CM NiTi instruments compared with conventional NiTi instruments (P wire at both curvatures (P Wire had a significantly higher N(f) and lower surface strain amplitude than the conventional NiTi wire files with identical design. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. Test and Delivery of the Chemin Mineralogical Instrument for Mars Science Laboratory

    Science.gov (United States)

    Blake, D. F.; Vaniman, D.; Anderson, R.; Bish, D.; Chipera, S.; Chemtob, S.; Crisp, J.; DesMarais, D. J.; Downs, R.; Feldman, S.; hide

    2010-01-01

    The CheMin mineralogical instrument on MSL will return quantitative powder X-ray diffraction data (XRD) and qualitative X-ray fluorescence data (XRF; 14

  1. Tests with different kind of k Vp-meters in standard X-rays beams used for instruments calibration, in diagnostic radiology level

    International Nuclear Information System (INIS)

    Lucena, Rodrigo Ferreira de; Potiens, Maria da Penha A.; Caldas, Linda V. E.; Vivolo, Vitor

    2008-01-01

    In this work, tests were carried out in one X-ray system, Medicor Moevek Roentgengyara, Model Neo-Diagnomax, (single-phase, full wave rectified) that operate in the range from 40 kV to 100 kV, and fixed 6 mA in the fluoroscopic mode, with total filtration of 2.5 mmAl. It was used as reference system an invasive system from Radcal, model Dynalyzer III (trade mark). The equipment tested were three non-invasive instruments, one PTW,model Diavolt (trade mark), and two Victoreen, model NERO (trade mark). It was performed measurements with those equipment, in the range from 50 kV to 100 kV, in steps of 10 kV and current of 6 mA (fixed). The quantity measured was kVp max . The results showed the maximum variation of 3 % for one NERO (trade mark) and 1 % for the other equipment of the same type, and 0,3 % for Diavolt (trade mark) related to the invasive reference measurement system. The differences in the obtained values could be caused by the different kind of equipment used in that, their manufacturer calibration and aged. (author)

  2. COMPARISON OF A HEAD MOUNTED IMPACT MEASUREMENT DEVICE TO THE HYBRID III ANTHROPOMORPHIC TESTING DEVICE IN A CONTROLLED LABORATORY SETTING.

    Science.gov (United States)

    Schussler, Eric; Stark, David; Bolte, John H; Kang, Yun Seok; Onate, James A

    2017-08-01

    Reports estimate that 1.6 to 3.8 million cases of concussion occur in sports and recreation each year in the United States. Despite continued efforts to reduce the occurrence of concussion, the rate of diagnosis continues to increase. The mechanisms of concussion are thought to involve linear and rotational head accelerations and velocities. One method of quantifying the kinematics experienced during sport participation is to place measurement devices into the athlete's helmet or directly on the athlete's head. The purpose of this research to determine the accuracy of a head mounted device for measuring the head accelerations experienced by the wearer. This will be accomplished by identifying the error in Peak Linear Acceleration (PLA), Peak Rotational Acceleration (PRA) and Peak Rotational Velocity (PRV) of the device. Laboratory study. A helmeted Hybrid III 50th percentile male headform was impacted via a pneumatic ram from the front, side, rear, front oblique and rear oblique at speeds from 1.5 to 5 m/s. The X2 Biosystems xPatch® (Seattle, WA) sensor was placed on the headform's right side at the approximate location of the mastoid process. Measures of PLA, PRA, PRV from the xPatch ® and Hybrid III were analyzed for Root Mean Square Error (RMSE), and Absolute and Relative Error (AE, RE). Seventy-six impacts were analyzed. All measures of correlation, fixed through the origin, were found to be strong: PLA R 2 =0.967 pstandard yet above the average error of testing devices in both PLA and PRA, but a low error in PRV. PLA measures from the xPatch® system demonstrated a high level of correlation with the PLA data from the Hybrid III mounted data collection system. 3.

  3. Anticipating the friction coefficient of friction materials used in automobiles by means of machine learning without using a test instrument

    OpenAIRE

    TİMUR, Mustafa; AYDIN, Fatih

    2013-01-01

    The most important factor for designs in which friction materials are used is the coefficient of friction. The coefficient of friction has been determined taking such variants as velocity, temperature, and pressure into account, which arise from various factors in friction materials, and by analyzing the effects of these variants on friction materials. Many test instruments have been produced in order to determine the coefficient of friction. In this article, a study about the use ...

  4. The ChemCam Instrument Suite on the Mars Science Laboratory (MSL) Rover: Body Unit and Combined System Tests

    International Nuclear Information System (INIS)

    Wiens, Roger C.; Barraclough, Bruce; Barkley, Walter C.; Bender, Steve; Bernardin, John; Bultman, Nathan; Clanton, Robert C.; Clegg, Samuel; Delapp, Dorothea; Dingler, Robert; Enemark, Don; Flores, Mike; Hale, Thomas; Lanza, Nina; Lasue, Jeremie; Latino, Joseph; Little, Cynthia; Morrison, Leland; Nelson, Tony; Romero, Frank; Salazar, Steven; Stiglich, Ralph; Storms, Steven; Trujillo, Tanner; Ulibarri, Mike; Vaniman, David; Whitaker, Robert; Witt, James; Maurice, Sylvestre; Bouye, Marc; Cousin, Agnes; Cros, Alain; D'Uston, Claude; Forni, Olivier; Gasnault, Olivier; Kouach, Driss; Lasue, Jeremie; Pares, Laurent; Poitrasson, Franck; Striebig, Nicolas; Thocaven, Jean-Jacques; Saccoccio, Muriel; Perez, Rene; Bell, James F. III; Hays, Charles; Blaney, Diana; DeFlores, Lauren; Elliott, Tom; Kan, Ed; Limonadi, Daniel; Lindensmith, Chris; Miller, Ed; Reiter, Joseph W.; Roberts, Tom; Simmonds, John J.; Warner, Noah; Blank, Jennifer; Bridges, Nathan; Cais, Phillippe; Clark, Benton; Cremers, David; Dyar, M. Darby; Fabre, Cecile; Herkenhoff, Ken; Kirkland, Laurel; Landis, David; Langevin, Yves; Lanza, Nina; Newsom, Horton; Ollila, Ann; LaRocca, Frank; Ott, Melanie; Mangold, Nicolas; Manhes, Gerard; Mauchien, Patrick; Blank, Jennifer; McKay, Christopher; Mooney, Joe; Provost, Cheryl; Morris, Richard V.; Sautter, Violaine; Sautter, Violaine; Waterbury, Rob; Wong-Swanson, Belinda; Barraclough, Bruce; Bender, Steve; Vaniman, David

    2012-01-01

    The ChemCam instrument suite on the Mars Science Laboratory (MSL) rover Curiosity provides remote compositional information using the first laser-induced breakdown spectrometer (LIBS) on a planetary mission, and provides sample texture and morphology data using a remote micro-imager (RMI). Overall, ChemCam supports MSL with five capabilities: remote classification of rock and soil characteristics; quantitative elemental compositions including light elements like hydrogen and some elements to which LIBS is uniquely sensitive (e.g., Li, Be, Rb, Sr, Ba); remote removal of surface dust and depth profiling through surface coatings; context imaging; and passive spectroscopy over the 240-905 nm range. ChemCam is built in two sections: The mast unit, consisting of a laser, telescope, RMI, and associated electronics, resides on the rover's mast, and is described in a companion paper. ChemCam's body unit, which is mounted in the body of the rover, comprises an optical de-multiplexer, three spectrometers, detectors, their coolers, and associated electronics and data handling logic. Additional instrument components include a 6 m optical fiber which transfers the LIBS light from the telescope to the body unit, and a set of onboard calibration targets. ChemCam was integrated and tested at Los Alamos National Laboratory where it also underwent LIBS calibration with 69 geological standards prior to integration with the rover. Post-integration testing used coordinated mast and instrument commands, including LIBS line scans on rock targets during system-level thermal-vacuum tests. In this paper we describe the body unit, optical fiber, and calibration targets, and the assembly, testing, and verification of the instrument prior to launch. (authors)

  5. Development and testing of the Youth Alcohol Norms Survey (YANS) instrument to measure youth alcohol norms and psychosocial influences.

    Science.gov (United States)

    Burns, Sharyn K; Maycock, Bruce; Hildebrand, Janina; Zhao, Yun; Allsop, Steve; Lobo, Roanna; Howat, Peter

    2018-05-14

    This study aimed to develop and validate an online instrument to: (1) identify common alcohol-related social influences, norms and beliefs among adolescents; (2) clarify the process and pathways through which proalcohol norms are transmitted to adolescents; (3) describe the characteristics of social connections that contribute to the transmission of alcohol norms; and (4) identify the influence of alcohol marketing on adolescent norm development. The online Youth Alcohol Norms Survey (YANS) was administered in secondary schools in Western Australia PARTICIPANTS: Using a 2-week test-retest format, the YANS was administered to secondary school students (n=481, age=13-17 years, female 309, 64.2%). The development of the YANS was guided by social cognitive theory and comprised a systematic multistage process including evaluation of content and face validity. A 2-week test-retest format was employed. Exploratory factor analysis was conducted to determine the underlying factor structure of the instrument. Test-retest reliability was examined using intraclass correlation coefficient (ICC) and Cohen's kappa. A five-factor structure with meaningful components and robust factorial loads was identified, and the five factors were labelled as 'individual attitudes and beliefs', 'peer and community identity', 'sibling influences', 'school and community connectedness' and 'injunctive norms', respectively. The instrument demonstrated stability across the test-retest procedure (ICC=0.68-0.88, Cohen's kappa coefficient=0.69) for most variables. The results support the reliability and factorial validity of this instrument. The YANS presents a promising tool, which enables comprehensive assessment of reciprocal individual, behavioural and environmental factors that influence alcohol-related norms among adolescents. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise

  6. Industrial Arts Test Development, Book III. Resource Items for Graphics Technology, Power Technology, Production Technology.

    Science.gov (United States)

    New York State Education Dept., Albany.

    This booklet is designed to assist teachers in developing examinations for classroom use. It is a collection of 955 objective test questions, mostly multiple choice, for industrial arts students in the three areas of graphics technology, power technology, and production technology. Scoring keys are provided. There are no copyright restrictions,…

  7. Compilation of radiation damage test data part III: materials used around high-energy accelerators

    CERN Document Server

    Beynel, P; Schönbacher, H; CERN. Geneva

    1982-01-01

    For pt.II see CERN report 79-08 (1979). This handbook gives the results of radiation damage tests on various engineering materials and components intended for installation in radiation areas of the CERN high-energy particle accelerators. It complements two previous volumes covering organic cable-insulating materials and thermoplastic and thermosetting resins.

  8. 77 FR 11651 - Hybrid III 10-Year-Old Child Test Dummy

    Science.gov (United States)

    2012-02-27

    ... words, chin-to- chest contact often caused HIC to exceed the injury assessment reference value (HIC 36... bag tests).\\19\\ \\19\\ The computation of HIC applies a higher signal filter class (CFC 1000 vs. CFC 180... Dorel provided a picture of a torn bib assembly, without further discussion, in its response to the Part...

  9. Retrofit of waste-to-energy facilities equipped with electrostatic precipitators. Volume III: Test protocol

    Energy Technology Data Exchange (ETDEWEB)

    Rigo, H.G. [Rigo & Rigo Associates, Inc., Berea, OH (US); Chandler, A.J. [A.J. Chandler & Associates, Inc., Toronto, Ontario (Canada)

    1996-04-01

    The American Society of Mechanical Engineers' [ASME] Center for Research and Technology Development [CRTD] has been awarded a subcontract by the National Renewable Energy Laboratory [NREL] to demonstrate the technical performance and viability of flue gas temperature control in combination with dry acid gas reagent and activated carbon injection at an existing electrostatic precipitator [ESP] equipped municipal waste combustor [MWC]. The objective of this proof-of-concept demonstration test is to economically and reliably meet 40 CFR 60 Subpart Cb Emissions Guidelines for MWC's at existing ESP equipped facilities. The effort is being directed by a Subcommittee of tile ASME Research Committee on Industrial and Municipal Wastes [RCIMW] chaired by Dave Hoecke. Mr. Greg Barthold of ASME/CRTD is the Project Manager. ASME/CRTD contracted with Rigo & Rigo Associates, Inc. in cooperation with A.J. Chandler & Associates, Ltd. to be the Principal Investigator for the project and manage the day-t o-day aspects of the program, conduct the testing reduce and interpret the data and prepare the report. Testing will be conducted at the 2 by 210 TPD, ESP equipped MWC at the Davis County Resource Recovery Facility in Layton, Utah. The test plan calls for duplicate metals (Cd, Pb and Hg), dioxin and acid gas runs.

  10. The dynamic version of the Bayley-III : Test results and the opinion of practitioners

    NARCIS (Netherlands)

    Visser, Linda; Ruiter, Selma; van der Meulen, Bieuwe; Ruijssenaars, Wied; Timmerman, Marieke

    When problems are suspected with the development of a child, developmental assessment is often carried out as part of the diagnostic process (American Academy of Pediatrics, 2001). The test scores obtained indicate the levels of functioning at that moment in time in the domains investigated. This

  11. Charpy impact test results on five materials and NIST verification specimens using instrumented 2-mm and 8-mm strikers

    International Nuclear Information System (INIS)

    Nanstad, R.K.; Sokolov, M.A.

    1995-01-01

    The Heavy-Section Steel Irradiation Program at Oak Ridge National Laboratory is involved in two cooperative projects, with international participants, both of which involve Charpy V-notch impact tests with instrumented strikers of 2mm and 8mm radii. Two heats of A 533 grade B class I pressure vessel steel and a low upper-shelf (LUS) submerged-arc (SA) weld were tested on the same Charpy machine, while one heat of a Russian Cr-Mo-V forging steel and a high upper-shelf (HUS) SA weld were tested on two different machines. The number of replicate tests at any one temperature ranged from 2 to 46 specimens. Prior to testing with each striker, verification specimens at the low, high, and super high energy levels from the National Institute of Standards and Technology (NIST) were tested. In the two series of verification tests, the tests with the 2mm striker met the requirements at the low and high energy levels but not at the super high energy. For one plate, the 2mm striker showed somewhat higher average absorbed energies than those for the 8-mm striker at all three test temperatures. For the second plate and the LUS weld, however, the 2mm striker showed somewhat lower energies at both test temperatures. For the Russian forging steel and the HUS weld, tests were conducted over a range of temperatures with tests at one laboratory using the 8mm striker and tests at a second laboratory using the 2mm striker. Lateral expansion was measured for all specimens and the results are compared with the absorbed energy results. The overall results showed generally good agreement (within one standard deviation) in energy measurements by the two strikers. Load-time traces from the instrumented strikers were also compared and used to estimate shear fracture percentage. Four different formulas from the European Structural Integrity Society draft standard for instrumented Charpy test are compared and a new formula is proposed for estimation of percent shear from the force-time trace

  12. GALEN skin test study III: Minimum battery of test inhalent allergens needed in epidemiological studies in patients

    DEFF Research Database (Denmark)

    Bousquet, P-J; Burbach, G; Heinzerling, L M

    2009-01-01

    Background: The number of allergens to be tested in order to identify sensitized patients is important in order to have the most cost-effective approach in epidemiological studies. Objective: To define the minimal number and the type of skin prick test (SPT) allergens required to identify a patient...... the allergens selection. Result: Among the 3034 patients involved, 1996 (68.2%) were sensitized to at least one allergen. Overall, eight allergens (grass pollen, Dermatophagoides pteronyssinus, birch pollen, cat dander, Artemisia, olive pollen, Blatella and Alternaria) allowed to identified more than 95......% of sensitized subjects. However, differences were observed between countries, two allergens being sufficient for Switzerland (grass pollen and cat dander) as opposed to nine for France (grass pollen, Dermatophagoides pteronyssinus, olive pollen, cat dander, Blatella, cypress, dog dander, alder and [Artemisia...

  13. Design and Testing of a Controller for the Martian Atmosphere Pressure and Humidity Instrument DREAMS-P/H

    Science.gov (United States)

    Tapani Nikkanen, Timo; Schmidt, Walter; Genzer, Maria; Harri, Ari-Matti; Haukka, Harri

    2013-04-01

    The European Space Agency (ESA), driven by the goal of performing a soft landing on Mars, is planning to launch the Entry, descent and landing Demonstrator Module (EDM)[1] simultaneously with the Trace Gas Orbiter (TGO) as a part of the ExoMars program towards Mars in 2016. As a secondary objective, the EDM will gather meteorological data and observe the electrical environment of the landing site with its Dust characterisation, Risk assessment, and Environmental Analyser on the Martian Surface (DREAMS). The Finnish Meteorological Institute (FMI) is participating in the project by designing, building and testing a pressure and a humidity instrument for Mars, named DREAMS-P and DREAMS-H, respectively. The instruments are based on previous FMI designs, including ones flown on board the Huygens, Phoenix and Mars Science Laboratory.[2] Traditionally, the FMI pressure and humidity instruments have been controlled by an FPGA. However, the need to incorporate more autonomy and modifiability into instruments, cut the development time and component costs, stimulated interest to study a Commercial Off-The-Shelf (COTS) Microcontroller Unit (MCU) based instrument design. Thus, in the DREAMS-P/H design, an automotive MCU is used as the instrument controller. The MCU has been qualified for space by tests in and outside FMI. The DREAMS-P/H controller command and data interface utilizes a RS-422 connection to receive telecommands from and to transmit data to the Central Electronics Unit (CEU) of the DREAMS science package. The two pressure transducers of DREAMS-P and one humidity transducer of DREAMS-H are controlled by a single MCU. The MCU controls the power flow for each transducer and performs pulse counting measurements on sensor and reference channels to retrieve scientific data. Pressure and humidity measurements are scheduled and set up according to a configuration table assigned to each transducer. The configuration tables can be modified during the flight. The whole

  14. Some Hardware and Instrumentation Aspects of the Development of an Automation System for Jar Tests in Drinking Water Treatment.

    Science.gov (United States)

    Calderón, Antonio José; González, Isaías

    2017-10-11

    The so-called Jar Test (JT) plays a vital role in the drinking water and wastewater treatments for establishing the dosage of flocculants and coagulant. This test is a well-proved laboratory instrumental procedure performed by trained personnel. In this work, a completely novel system for the automation and monitoring of a JT devoted to drinking water treatment is presented. It has been implemented using an industrial programmable controller and sensors and instruments specifically selected for this purpose. Once the parameters of the test have been entered, the stages that compose the JT (stirring, coagulant addition, etc.) are sequentially performed without human intervention. Moreover, all the involved measurements from sensors are collected and made accessible for continuous monitoring of the process. By means of the proposed system, the JT procedure is conducted fully automatically and can be locally and remotely monitored in real-time. Furthermore, the developed system constitutes a portable laboratory that offers advantageous features like scalability and transportability. The proposed system is described focusing on hardware and instrumentation aspects, and successful results are reported.

  15. Some Hardware and Instrumentation Aspects of the Development of an Automation System for Jar Tests in Drinking Water Treatment

    Science.gov (United States)

    2017-01-01

    The so-called Jar Test (JT) plays a vital role in the drinking water and wastewater treatments for establishing the dosage of flocculants and coagulant. This test is a well-proved laboratory instrumental procedure performed by trained personnel. In this work, a completely novel system for the automation and monitoring of a JT devoted to drinking water treatment is presented. It has been implemented using an industrial programmable controller and sensors and instruments specifically selected for this purpose. Once the parameters of the test have been entered, the stages that compose the JT (stirring, coagulant addition, etc.) are sequentially performed without human intervention. Moreover, all the involved measurements from sensors are collected and made accessible for continuous monitoring of the process. By means of the proposed system, the JT procedure is conducted fully automatically and can be locally and remotely monitored in real-time. Furthermore, the developed system constitutes a portable laboratory that offers advantageous features like scalability and transportability. The proposed system is described focusing on hardware and instrumentation aspects, and successful results are reported. PMID:29019943

  16. LOFT instrumentation

    International Nuclear Information System (INIS)

    Bixby, W.W.

    1979-01-01

    A description of instrumentation used in the Loss-of-Fluid Test (LOFT) large break Loss-of-Coolant Experiments is presented. Emphasis is placed on hydraulic and thermal measurements in the primary system piping and components, reactor vessel, and pressure suppression system. In addition, instrumentation which is being considered for measurement of phenomena during future small break testing is discussed. (orig.) 891 HP/orig. 892 BRE [de

  17. Comparison of Individual Performance in Intelligence Tests WAIS III and RPM (Raven's Progressive Matrices)

    OpenAIRE

    Petrů, Vít

    2017-01-01

    This thesis deals with replacement of performative scale of Wechsler Adult Intelligence Scale (3rd revision) through Raven's Standard Progressive Matrices and Advanced Progressive Matrices. In the theoretical part introduces the concepts of intelligence, approaches to its exploration and intelligence tests. The theoretical part is also devoted to the description of the used methods and presents an overview of the research on a similar theme as this work. In the empirical part of the thesis is...

  18. Standard practice of calibration of force-measuring instruments for verifying the force indication of testing machines

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 The purpose of this practice is to specify procedures for the calibration of force-measuring instruments. Procedures are included for the following types of instruments: 1.1.1 Elastic force-measuring instruments, and 1.1.2 Force-multiplying systems, such as balances and small platform scales. Note 1Verification by deadweight loading is also an acceptable method of verifying the force indication of a testing machine. Tolerances for weights for this purpose are given in Practices E 4; methods for calibration of the weights are given in NIST Technical Note 577, Methods of Calibrating Weights for Piston Gages. 1.2 The values stated in SI units are to be regarded as the standard. Other metric and inch-pound values are regarded as equivalent when required. 1.3 This practice is intended for the calibration of static force measuring instruments. It is not applicable for dynamic or high speed force calibrations, nor can the results of calibrations performed in accordance with this practice be assumed valid for...

  19. Instrumented impact testing as a way to obtain further information on the behaviour of steel in welded constructions

    International Nuclear Information System (INIS)

    Nielsen, A.

    1976-05-01

    Based on experience gained from instrumented impact testing of ten different mild steels using test pieces of different geometrical shape (Charpy V-notch, Charpy knife-notch, DVM, Schnadt K 0 , Ksub(0.5), K 1 and K 2 ), some general features of the fracture process during impact testing are discussed. Steels can be divided into two main groups that are significantly different with respect to the behaviour during Charpy V-notch testing. The difference vanishes when a crack-like notch is used, and other properties of steel are revealed. It is evident that, even when modified impact testing bears little resemblance to what is happening in an actual steel construction. For the purpose of investigating the fracture conditions in welds, it seems more significant to relate the dynamic aspects to the speed of propagation of the crack when it starts to penetrate the volume considered at a certain stress level. (author)

  20. The development and psychometric testing of a theory-based instrument to evaluate nurses' perception of clinical reasoning competence.

    Science.gov (United States)

    Liou, Shwu-Ru; Liu, Hsiu-Chen; Tsai, Hsiu-Min; Tsai, Ying-Huang; Lin, Yu-Ching; Chang, Chia-Hao; Cheng, Ching-Yu

    2016-03-01

    The purpose of the study was to develop and psychometrically test the Nurses Clinical Reasoning Scale. Clinical reasoning is an essential skill for providing safe and quality patient care. Identifying pre-graduates' and nurses' needs and designing training courses to improve their clinical reasoning competence becomes a critical task. However, there is no instrument focusing on clinical reasoning in the nursing profession. Cross-sectional design was used. This study included the development of the scale, a pilot study that preliminary tested the readability and reliability of the developed scale and a main study that implemented and tested the psychometric properties of the developed scale. The Nurses Clinical Reasoning Scale was developed based on the Clinical Reasoning Model. The scale includes 15 items using a Likert five-point scale. Data were collected from 2013-2014. Two hundred and fifty-one participants comprising clinical nurses and nursing pre-graduates completed and returned the questionnaires in the main study. The instrument was tested for internal consistency and test-retest reliability. Its validity was tested with content, construct and known-groups validity. One factor emerged from the factor analysis. The known-groups validity was confirmed. The Cronbach's alpha for the entire instrument was 0·9. The reliability and validity of the Nurses Clinical Reasoning Scale were supported. The scale is a useful tool and can be easily administered for the self-assessment of clinical reasoning competence of clinical nurses and future baccalaureate nursing graduates. Study limitations and further recommendations are discussed. © 2015 John Wiley & Sons Ltd.

  1. The Impact of Scholastic Instrumental Music and Scholastic Chess Study on the Standardized Test Scores of Students in Grades Three, Four, and Five

    Science.gov (United States)

    Martinez, Edwin E.

    2012-01-01

    This study examines the impact of instrumental music study and group chess lessons on the standardized test scores of suburban elementary public school students (grades three through five) in Levittown, New York. The study divides the students into the following groups and compares the standardized test scores of each: a) instrumental music…

  2. Evaluation tests of the Instrumentation and Control equipment to use in nuclear power plants: its contribution to the improvement and quality certification of the Brazilian equipment

    International Nuclear Information System (INIS)

    Menezes, R.H.M. de; Peluso, M.A.V.

    1984-01-01

    This work presents the procedures used to evaluate Instrumentation Control equipment and reports the experience of integration among instrument user, manufacturer and test institution. It covers tests for equipments for conventional user and for specific application in Nuclear Power Stations. (Author) [pt

  3. Upgrade the startup test instrumentation (ANMS) with innovated I and C system at the Dukovany WWER 440/213 units

    International Nuclear Information System (INIS)

    Kocek, V.

    2005-01-01

    The paper focuses on the innovation procedures of physics startup tests instrumentation used in Dukovany NPP (ANMS) connected with I and C system refurbishment of the Dukovany WWER 440/213 units. The following matters are further discussed in this paper: a) changes in ANMS design, whose has been carried out due to reflect the situation connected with I and C innovation; b) process of consistency checking during implementation stage; c) results of the physics startup tests with upgraded ANMS in 2005 (introduction of Gd2 fuel on Dukovany NPP) (Authors)

  4. Nuclear electronic equipment for control and monitoring panel. Procedure guide for on-site tests of nuclear reactor instruments

    International Nuclear Information System (INIS)

    1975-10-01

    By the use of a procedure for on-site testing of nuclear reactor instruments it should be possible to judge their ability to guarantee the reactor safety and availability at the moment of divergence or during operation. Such a procedure must therefore be created as a work implement for the quick and reliable installation of electronic devices necessary for nuclear reactor control and supervision. A standard document is proposed for this purpose, allowing a ''test programme'' to be set up before the equipment is installed on the site [fr

  5. Instrumentation, Field Network and Process Automation for the Cryogenic System of the LHC Test String

    CERN Document Server

    Suraci, A; Balle, C; Blanco-Viñuela, E; Casas-Cubillos, J; Gomes, P; Pelletier, S; Serio, L; Vauthier, N; Balle, Ch.

    2001-01-01

    CERN is now setting up String 2, a full-size prototype of a regular cell of the LHC arc. It is composed of two quadrupole, six dipole magnets, and a separate cryogenic distribution line (QRL) for the supply and recovery of the cryogen. An electrical feed box (DFB), with up to 38 High Temperature Superconducting (HTS) leads, powers the magnets. About 700 sensors and actuators are distributed along four Profibus DP and two Profibus PA field buses. The process automation is handled by two controllers, running 126 Closed Control Loops (CCL). This paper describes the cryogenic control system, associated instrumentation, and their commissioning.

  6. Drugs as instruments: Describing and testing a behavioral approach to the study of neuroenhancement

    Directory of Open Access Journals (Sweden)

    Ralf Brand

    2016-08-01

    Full Text Available Neuroenhancement (NE is the non-medical use of psychoactive substances to produce a subjective enhancement in psychological functioning and experience. So far empirical investigations of individuals’ motivation for NE however have been hampered by the lack of theoretical foundation. This study aimed to apply drug instrumentalization theory to user motivation for NE. We argue that NE should be defined and analyzed from a behavioral perspective rather than in terms of the characteristics of substances used for NE. In the empirical study we explored user behavior by analyzing relationships between drug options (use over-the-counter products, prescription drugs, illicit drugs and postulated drug instrumentalization goals (e.g. improved cognitive performance, counteracting fatigue, improved social interaction. Questionnaire data from 1,438 university students were subjected to exploratory and confirmatory factor analysis to address the question of whether analysis of drug instrumentalization should be based on the assumption that users are aiming to achieve a certain goal and choose their drug accordingly or whether NE behavior is more strongly rooted in a decision to try or use a certain drug option. We used factor mixture modeling to explore whether users could be separated into qualitatively different groups defined by a shared ‘goal × drug option’ configuration. Our results indicate, first, that individuals’ decisions about NE are eventually based on personal attitude to drug options (e.g. willingness to use an over-the-counter product but not to abuse prescription drugs rather than motivated by desire to achieve a specific goal (e.g. fighting tiredness for which different drug options might be tried. Second, data analyses suggested two qualitatively different classes of users. Both predominantly used over-the-counter products, but ‘neuroenhancers’ might be characterized by a higher propensity to instrumentalize over

  7. KOH concentration effect on cycle life of nickel-hydrogen cells. III - Cycle life test

    Science.gov (United States)

    Lim, H. S.; Verzwyvelt, S. A.

    1988-01-01

    A cycle life test of Ni/H2 cells containing electrolytes of various KOH concentrations and a sintered type nickel electrode was carried out at 23 C using a 45 min accelerated low earth orbit (LEO) cycle regime at 80 percent depth of discharge. One of three cells containing 26 percent KOH has achieved over 28,000 cycles, and the other two 19,000 cycles, without a sign of failure. Two other cells containing 31 percent KOH electrolyte, which is the concentration presently used in aerospace cells, failed after 2,979 and 3,620 cycles. This result indicates that the cycle life of the present type of Ni/H2 cells may be extended by a factor of 5 to 10 simply by lowering the KOH concentration. Long cycle life of a Ni/H2 battery at high depth-of-discharge operation is desired, particularly for an LEO spacecraft application. Typically, battery life of about 30,000 cycles is required for a five year mission in an LEO. Such a cycle life with presently available cells can be assured only at a very low depth-of-discharge operation. Results of testing already show that the cycle life of an Ni/H2 cell is tremendously improved by simply using an electrolyte of low KOH concentration.

  8. Test of ground-based Lidar instrument WLS200S-10

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula

    This report presents the result of the test performed for the given Windcube at DTU’s test site for large wind turbine at Høvsøre, Denmark. The test aims at establishing a relation between the reference wind measurements and corresponding lidar wind indications, and evaluating a set of quality...

  9. Test of ground-based Lidar instrument WLS200S-11

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula

    This report presents the result of the test performed for the given Windcube at DTU’s test site for large wind turbine at Høvsøre, Denmark. The test aims at establishing a relation between the reference wind measurements and corresponding lidar wind indications, and evaluating a set of quality...

  10. Test of ground-based Lidar instrument WLS7-106

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula

    This report presents the result of the test performed for the given Windcube at DTU’s test site for large wind turbine at Høvsøre, Denmark. The test aims at establishing a relation between the reference wind measurements and corresponding lidar wind indications, and evaluating a set of quality...

  11. Test of ground-based lidar instrument WLS7-159

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Wagner, Rozenn

    This report presents the result of the test performed for the given Windcube at DTU’s test site for large wind turbine at Høvsøre, Denmark. The test aims at establishing a relation between the reference wind measurements and corresponding lidar wind indications, and evaluating a set of quality...

  12. Testing the Deployment Repeatability of a Precision Deployable Boom Prototype for the Proposed SWOT Karin Instrument

    Science.gov (United States)

    Agnes, Gregory S.; Waldman, Jeff; Hughes, Richard; Peterson, Lee D.

    2015-01-01

    NASA's proposed Surface Water Ocean Topography (SWOT) mission, scheduled to launch in 2020, would provide critical information about Earth's oceans, ocean circulation, fresh water storage, and river discharge. The mission concept calls for a dual-antenna Ka-band radar interferometer instrument, known as KaRIn, that would map the height of water globally along two 50 km wide swaths. The KaRIn antennas, which would be separated by 10 meters on either side of the spacecraft, would need to be precisely deployable in order to meet demanding pointing requirements. Consequently, an effort was undertaken to design build and prototype a precision deployable Mast for the KaRIn instrument. Each mast was 4.5-m long with a required dilitation stability of 2.5 microns over 3 minutes. It required a minimum first mode of 7 Hz. Deployment repeatability was less than +/- 7 arcsec in all three rotation directions. Overall mass could not exceed 41.5 Kg including any actuators and thermal blanketing. This set of requirements meant the boom had to be three times lighter and two orders of magnitude more precise than the existing state of the art for deployable booms.

  13. In core instrumentation for online nuclear heating measurements of material testing reactor

    International Nuclear Information System (INIS)

    Reynard, C.; Andre, J.; Brun, J.; Carette, M.; Janulyte, A.; Merroun, O.; Zerega, Y.; Lyoussi, A.; Bignan, G.; Chauvin, J-P.; Fourmentel, D.; Glayse, W.; Gonnier, C.; Guimbal, P.; Iracane, D.; Villard, J.-F.

    2010-01-01

    The present work focuses on nuclear heating. This work belongs to a new advanced research program called IN-CORE which means 'Instrumentation for Nuclear radiations and Calorimetry Online in REactor' between the LCP (University of Provence-CNRS) and the CEA (French Atomic Energy Commission) - Jules Horowitz Reactor (JHR) program. This program started in September 2009 and is dedicated to the conception and the design of an innovative mobile experimental device coupling several sensors and ray detectors for on line measurements of relevant physical parameters (photonic heating, neutronic flux ...) and for an accurate parametric mapping of experimental channels in the JHR Core. The work presented below is the first step of this program and concerns a brief state of the art related to measurement methods of nuclear heating phenomena in research reactor in general and MTR in particular. A special care is given to gamma heating measurements. A first part deals with numerical codes and models. The second one presents instrumentation divided into various kinds of sensor such as calorimeter measurements and gamma ionization chamber measurements. Their basic principles, characteristics such as metrological parameters, operating mode, disadvantages/advantages, ... are discussed. (author)

  14. [Quality of advanced practice nurse counseling in home care settings (APN-BQ): psychometric testing of the instrument].

    Science.gov (United States)

    Petry, Heidi; Suter-Riederer, Susanne; Kerker-Specker, Carmen; Imhof, Lorenz

    2014-12-01

    Patient centred and individually-tailored counselling of older people with a chronic condition who live at home is a useful intervention to support their independence. The paper presents the development and psychometric testing of the APN-BQ Instrument, to measure patient-centeredness. To measure the quality of an in-home counselling intervention, a 23-item questionnaire was developed and tested with 206 people 80 years and older. Principal component analysis with Varimax Rotation was conducted (n = 206). Analysis revealed a four factor (fs = 0.91) model scoring in 19 items. All factors loaded > 0.45. Cronbach's alpha was 0.86. The utility and acceptance of the instrument was confirmed by the high response rate (100 %) and the fact that participants answered 98.8 % of all questions. The APN-BQ has shown to be a reliable Instrument with good content and construct validity. It is a tool for APNs to measure structure, process, and outcome quality of a patient-centred and individually-tailored counselling program, including the degree of patient participation, and patient empowerment.

  15. 'Mechanical restraint-confounders, risk, alliance score': testing the clinical validity of a new risk assessment instrument.

    Science.gov (United States)

    Deichmann Nielsen, Lea; Bech, Per; Hounsgaard, Lise; Alkier Gildberg, Frederik

    2017-08-01

    Unstructured risk assessment, as well as confounders (underlying reasons for the patient's risk behaviour and alliance), risk behaviour, and parameters of alliance, have been identified as factors that prolong the duration of mechanical restraint among forensic mental health inpatients. To clinically validate a new, structured short-term risk assessment instrument called the Mechanical Restraint-Confounders, Risk, Alliance Score (MR-CRAS), with the intended purpose of supporting the clinicians' observation and assessment of the patient's readiness to be released from mechanical restraint. The content and layout of MR-CRAS and its user manual were evaluated using face validation by forensic mental health clinicians, content validation by an expert panel, and pilot testing within two, closed forensic mental health inpatient units. The three sub-scales (Confounders, Risk, and a parameter of Alliance) showed excellent content validity. The clinical validations also showed that MR-CRAS was perceived and experienced as a comprehensible, relevant, comprehensive, and useable risk assessment instrument. MR-CRAS contains 18 clinically valid items, and the instrument can be used to support the clinical decision-making regarding the possibility of releasing the patient from mechanical restraint. The present three studies have clinically validated a short MR-CRAS scale that is currently being psychometrically tested in a larger study.

  16. Development of deterioration models and tests of structural materials for nuclear containment structures(III)

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Byung Hwan [Seoul National University, Seoul (Korea)

    2002-03-01

    The nuclear containment structures are very important infrastructures which require much cost for construction and maintenance. If these structures lose their functions and do not ensure their safety, great losses of human lives and properties will result. Therefore, the nuclear containment structures should secure appropriate safety and functions during these service lives. The nuclear concrete structures start to experience deterioration due to severe environmental condition, even though the concrete structures exhibit generally superior durability. It is, therefore, necessary to take appropriate actions at each stage of planning, design and construction to secure safety and functionability. Thorough examination of deterioration mechanism and comprehensive tests have been conducted to explore the durability characteristics of nuclear concrete structures. 88 refs., 70 figs., 12 tabs. (Author)

  17. Taking the Test Taker's Perspective: Response Process and Test Motivation in Multidimensional Forced-Choice Versus Rating Scale Instruments.

    Science.gov (United States)

    Sass, Rachelle; Frick, Susanne; Reips, Ulf-Dietrich; Wetzel, Eunike

    2018-03-01

    The multidimensional forced-choice (MFC) format has been proposed as an alternative to the rating scale (RS) response format. However, it is unclear how changing the response format may affect the response process and test motivation of participants. In Study 1, we investigated the MFC response process using the think-aloud technique. In Study 2, we compared test motivation between the RS format and different versions of the MFC format (presenting 2, 3, 4, and 5 items simultaneously). The response process to MFC item blocks was similar to the RS response process but involved an additional step of weighing the items within a block against each other. The RS and MFC response format groups did not differ in their test motivation. Thus, from the test taker's perspective, the MFC format is somewhat more demanding to respond to, but this does not appear to decrease test motivation.

  18. JHR Project: a future Material Testing Reactor working as an International user Facility: The key-role of instrumentation in support to the development of modern experimental capacity

    Energy Technology Data Exchange (ETDEWEB)

    Bignan, G. [CEA, DEN, DER, JHR user Facility Interface Manager' , Cadarache, F-13108 St-Paul-Lez-Durance (France); Gonnier, C. [CEA, DEN, DER, SRJH Jules Horowitz Reactor Service, Cadarache, F-13108 St-Paul-Lez-Durance (France); Lyoussi, A.; Villard, J.F.; Destouches, C. [CEA, DEN, DER, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St-Paul-Lez-Durance (France); Chauvin, J.P. [CEA,DEN, DER, SPEX, Experimental Physics Service, Cadarache, F-13108 St-Paul-Lez-Durance (France); Maugard, B. [CEA, DEN, DER, Reactor Department Studies, Cadarache, F-13108 St-Paul-Lez-Durance (France)

    2015-07-01

    Research and development on fuel and material behaviour under irradiation is a key issue for sustainable nuclear energy in order to meet specific needs by keeping the best level of safety. These needs mainly deal with a constant improvement of performances and safety in order to optimize the fuel cycle and hence to reach nuclear energy sustainable objectives. A sustainable nuclear energy requires a high level of performances in order to meet specific needs such as: - Pursuing improvement of the performances and safety of present and coming water cooled reactor technologies. This will require a continuous R and D support following a long-term trend driven by the plant life management, safety demonstration, flexibility and economics improvement. Experimental irradiations of structure materials are necessary to anticipate these material behaviours and will contribute to their optimisation. - Upgrading continuously nuclear fuel technology in present and future nuclear power plants to achieve better performances and to optimise the fuel cycle keeping the best level of safety. Fuel evolution for generation II, III and III+ is a key stake requiring developments, qualification tests and safety experiments to ensure the competitiveness and safety: experimental tests exploring the full range of fuel behaviour determine fuel stability limits and safety margins, as a major input for the fuel reliability analysis. To perform such accurate and innovative progress and developments, specific and ad hoc instrumentation, irradiation devices, measurement methods are necessary to be set up inside or beside the material testing reactor (MTR) core. These experiments require beforehand in situ and on line sophisticated measurements to accurately determine different key parameters such as thermal and fast neutron fluxes and nuclear heating in order to precisely monitor and control the conducted assays. The new Material Testing Reactor JHR (Jules Horowitz Reactor) currently under

  19. DESIGN AND TEST OF AN INSTRUMENT FOR MEASURING MICROTHERMAL SEEING ON THE MAGDALENA RIDGE

    International Nuclear Information System (INIS)

    Jorgensen, A. M.; Klinglesmith, D. A.; Speights, J.; Clements, A.; Patel, J.

    2009-01-01

    We have constructed and operated an automated instrument for measuring ground-level microthermal seeing at the Magdalena Ridge Observatory (MRO). The MRO is located at an altitude of 10500' in the Cibola National Forest in New Mexico, USA. It is the planned site for the MRO Optical Interferometer (MROI) planned for up to 10 collecting elements, each with a diameter of 1.4 m, and baselines eventually up to approximately 400 m. As part of the preparation for construction we deployed a system to characterize the ground-level seeing across the observatory site. The instrument is built largely of off-the-shelf components, with only the sensor head and power supply requiring electronic board assembly. Even in those cases the board architecture is very simple. The first proof-of-concept system was deployed for several weeks in the autumn of 2004, and has since undergone several iterations. The latest configuration operates entirely off batteries, incorporates wireless data acquisition, and is thus able to operate in an area with no shelter, power, or communications. In this paper we present the design of the instrument, and show initial data. The microthermal tower has four sensor pairs at heights from 0.8 to 4.41 m, significantly lower than other microthermal experiments, because of the need to characterize the seeing near the ground. We find significant variation in the contribution of this range of heights to the seeing, contributing up to 0.''3 of the seeing at some times and only 0.''02 at other times. The individual sensor power spectra have a slope in the range of 1.4--1.5, which is lower than the 1.67 slope predicted by Kolmogorov turbulence theory. We measure the well known effect of improved seeing immediately around sunset. While we find significant variation in the microthermal seeing, we did not find a pattern of corresponding variations in weather conditions, suggesting that a complicated set of factors control microthermal turbulence.

  20. Design and Test of an Instrument for Measuring Microthermal Seeing on the Magdalena Ridge

    Science.gov (United States)

    Jorgensen, A. M.; Klinglesmith, D. A., III; Speights, J.; Clements, A.; Patel, J.

    2009-05-01

    We have constructed and operated an automated instrument for measuring ground-level microthermal seeing at the Magdalena Ridge Observatory (MRO). The MRO is located at an altitude of 10500' in the Cibola National Forest in New Mexico, USA. It is the planned site for the MRO Optical Interferometer (MROI) planned for up to 10 collecting elements, each with a diameter of 1.4 m, and baselines eventually up to approximately 400 m. As part of the preparation for construction we deployed a system to characterize the ground-level seeing across the observatory site. The instrument is built largely of off-the-shelf components, with only the sensor head and power supply requiring electronic board assembly. Even in those cases the board architecture is very simple. The first proof-of-concept system was deployed for several weeks in the autumn of 2004, and has since undergone several iterations. The latest configuration operates entirely off batteries, incorporates wireless data acquisition, and is thus able to operate in an area with no shelter, power, or communications. In this paper we present the design of the instrument, and show initial data. The microthermal tower has four sensor pairs at heights from 0.8 to 4.41 m, significantly lower than other microthermal experiments, because of the need to characterize the seeing near the ground. We find significant variation in the contribution of this range of heights to the seeing, contributing up to 0farcs3 of the seeing at some times and only 0farcs02 at other times. The individual sensor power spectra have a slope in the range of 1.4--1.5, which is lower than the 1.67 slope predicted by Kolmogorov turbulence theory. We measure the well known effect of improved seeing immediately around sunset. While we find significant variation in the microthermal seeing, we did not find a pattern of corresponding variations in weather conditions, suggesting that a complicated set of factors control microthermal turbulence.