WorldWideScience

Sample records for inspiratory capacity ic

  1. Inspiratory Capacity during Exercise: Measurement, Analysis, and Interpretation

    Directory of Open Access Journals (Sweden)

    Jordan A. Guenette

    2013-01-01

    Full Text Available Cardiopulmonary exercise testing (CPET is an established method for evaluating dyspnea and ventilatory abnormalities. Ventilatory reserve is typically assessed as the ratio of peak exercise ventilation to maximal voluntary ventilation. Unfortunately, this crude assessment provides limited data on the factors that limit the normal ventilatory response to exercise. Additional measurements can provide a more comprehensive evaluation of respiratory mechanical constraints during CPET (e.g., expiratory flow limitation and operating lung volumes. These measurements are directly dependent on an accurate assessment of inspiratory capacity (IC throughout rest and exercise. Despite the valuable insight that the IC provides, there are no established recommendations on how to perform the maneuver during exercise and how to analyze and interpret the data. Accordingly, the purpose of this manuscript is to comprehensively examine a number of methodological issues related to the measurement, analysis, and interpretation of the IC. We will also briefly discuss IC responses to exercise in health and disease and will consider how various therapeutic interventions influence the IC, particularly in patients with chronic obstructive pulmonary disease. Our main conclusion is that IC measurements are both reproducible and responsive to therapy and provide important information on the mechanisms of dyspnea and exercise limitation during CPET.

  2. Inspiratory muscle load and capacity in chronic heart failure

    OpenAIRE

    Hart, N; Kearney, M T; Pride, N B; Green, M; Lofaso, F; Shah, A M; Moxham, J; Polkey, M I

    2004-01-01

    Background: Although breathlessness is common in chronic heart failure (CHF), the role of inspiratory muscle dysfunction remains unclear. We hypothesised that inspiratory muscle endurance, expressed as a function of endurance time (Tlim) adjusted for inspiratory muscle load and inspiratory muscle capacity, would be reduced in CHF.

  3. Cigarette smoking decreases dynamic inspiratory capacity during maximal exercise in patients with type 2 diabetes.

    Science.gov (United States)

    Kitahara, Yoshihiro; Hattori, Noboru; Yokoyama, Akihito; Yamane, Kiminori; Sekikawa, Kiyokazu; Inamizu, Tsutomu; Kohno, Nobuoki

    2012-06-01

    To investigate the influence of cigarette smoking on exercise capacity, respiratory responses and dynamic changes in lung volume during exercise in patients with type 2 diabetes. Forty-one men with type, 2 diabetes without cardiopulmonary disease were recruited and divided into 28 non-current smokers and 13 current smokers. All subjects received lung function tests and cardiopulmonary exercise testing using tracings of the flow-volume loop. Exercise capacity was compared using the percentage of predicted oxygen uptake at maximal workload (%VO2max). Respiratory variables and inspiratory capacity (IC) were compared between the two groups at rest and at 20%, 40%, 60%, 80% and 100% of maximum workload. Although there was no significant difference in lung function tests between the two groups, venous carboxyhemoglobin (CO-Hb) levels were significantly higher in current smokers. %VO2max was inversely correlated with CO-Hb levels. Changing patterns in respiratory rate, respiratory equivalent and IC were significantly different between the two groups. Current smokers had rapid breathing, a greater respiratory equivalent and a limited increase in IC during exercise. Cigarette smoking diminishes the increase in dynamic IC in patients with type 2 diabetes. As this effect of smoking on dynamic changes in lung volume will exacerbate dynamic hyperinflation in cases complicated by chronic obstructive pulmonary disease, physicians should consider smoking habits and lung function when evaluating exercise capacity in patients with type 2 diabetes.

  4. Benefits of short inspiratory muscle training on exercise capacity, dyspnea, and inspiratory fraction in COPD patients

    Directory of Open Access Journals (Sweden)

    Barakat Shahin

    2008-10-01

    Full Text Available Barakat Shahin1, Michele Germain2, Alzahouri Kazem3, Guy Annat41Department of Physiology, University of Claude Bernard Lyon I, Lyon, France; 2Chef of the Service of EFR, Hospital of the Croix-Rousse at Lyon, France; 3Department of Medical Informatics, Hospital of St. Julien, Nancy, France; 4Department of Physiology, UFR Médecine Lyon Grange-Blanche Université Claude Bernard Lyon I, INSERM ESPRI ERI 22, Lyon, FranceAbstract: Static lung hyperinflation has important clinical consequences in patients with chronic obstructive pulmonary disease (COPD. Given that most of these patients have respiratory and peripheral muscle weakness, dyspnea and functional exercise capacity may improve as a result of inspiratory muscle training (IMT. The present study is designed to investigate the benefits of a short outpatient program of IMT on inspiratory muscle performance, exercise capacity, perception of dyspnea, and the inspiratory fraction (IF. Thirty patients (24 males, 6 females with significant COPD (forced expiratory volume in one second [FEV1] = 46.21% ± 6.7% predicted, FEV1 = 33.6% ± 8.04% predicted were recruited for this study and had 3 months of IMT (30 minutes/day for 6 days/week in an outpatient clinic. Following IMT, there was a statistically significant increase in inspiratory muscle performance (an increase of the maximal inspiratory pressure from 59% ± 19.1% to 79% ± 21.85% predicted; p = 0.0342, a decrease in dyspnea (from 5.8 ± 0.78 to 1.9 ± 0.57; p = 0.0001, an increase in the distance walked during the 6 minute walk test, from 245 ± 52.37 m to 302 ± 41.30 m, and finally an increase in the IF (the new prognostic factor in COPD from 27.6 ± 9.7% to 31.4% ± 9.8%. The present study concludes that in patients with significant COPD, IMT results in improvement in performance, exercise capacity, sensation of dyspnea, and moreover an improvement in the IF prognostic factor.Keywords: inspiratory muscle training, dyspnea, inspiratory

  5. Inspiratory muscle training in patients with cystic fibrosis

    NARCIS (Netherlands)

    de Jong, W.; van Aalderen, W.M.C.; Kraan, J.; Koeter, G.H.; van der Schans, C.P.

    Little information is available about the effects of inspiratory muscle training in patients with cystic fibrosis (CF). In this study the effects of inspiratory-threshold loading in patients with CF on strength and endurance of the inspiratory muscles, pulmonary function, exercise capacity, dyspnoea

  6. A method of estimating inspiratory flow rate and volume from an inhaler using acoustic measurements

    International Nuclear Information System (INIS)

    Holmes, Martin S; D'Arcy, Shona; O'Brien, Ultan; Reilly, Richard B; Seheult, Jansen N; Geraghty, Colm; Costello, Richard W; Crispino O'Connell, Gloria

    2013-01-01

    Inhalers are devices employed to deliver medication to the airways in the treatment of respiratory diseases such as asthma and chronic obstructive pulmonary disease. A dry powder inhaler (DPI) is a breath actuated inhaler that delivers medication in dry powder form. When used correctly, DPIs improve patients' clinical outcomes. However, some patients are unable to reach the peak inspiratory flow rate (PIFR) necessary to fully extract the medication. Presently clinicians have no reliable method of objectively measuring PIFR in inhalers. In this study, we propose a novel method of estimating PIFR and also the inspiratory capacity (IC) of patients' inhalations from a commonly used DPI, using acoustic measurements. With a recording device, the acoustic signal of 15 healthy subjects using a DPI over a range of varying PIFR and IC values was obtained. Temporal and spectral signal analysis revealed that the inhalation signal contains sufficient information that can be employed to estimate PIFR and IC. It was found that the average power (P ave ) in the frequency band 300–600 Hz had the strongest correlation with PIFR (R 2 = 0.9079), while the power in the same frequency band was also highly correlated with IC (R 2 = 0.9245). This study has several clinical implications as it demonstrates the feasibility of using acoustics to objectively monitor inhaler use. (paper)

  7. Effects of inspiratory muscle training on pulmonary function, respiratory muscle strength and functional capacity in patients with atrial fibrillation: a randomized controlled trial.

    Science.gov (United States)

    Zeren, Melih; Demir, Rengin; Yigit, Zerrin; Gurses, Hulya N

    2016-12-01

    To investigate the effects of inspiratory muscle training on pulmonary function, respiratory muscle strength and functional capacity in patients with atrial fibrillation. Prospective randomized controlled single-blind study. Cardiology department of a university hospital. A total of 38 patients with permanent atrial fibrillation were randomly allocated to either a treatment group (n = 19; age 66.2 years (8.8)) or a control group (n = 19; age 67.1 years (6.4)). The training group received inspiratory muscle training at 30% of maximal inspiratory pressure for 15 minutes twice a day, 7 days a week, for 12 weeks alongside the standard medical treatment. The control group received standard medical treatment only. Spirometry, maximal inspiratory and expiratory pressures and 6-minute walking distance was measured at the beginning and end of the study. There was a significant increase in maximal inspiratory pressure (27.94 cmH 2 O (8.90)), maximal expiratory pressure (24.53 cmH 2 O (10.34)), forced vital capacity (10.29% (8.18) predicted), forced expiratory volume in one second (13.88% (13.42) predicted), forced expiratory flow 25%-75% (14.82% (12.44) predicted), peak expiratory flow (19.82% (15.62) predicted) and 6-minute walking distance (55.53 m (14.13)) in the training group (p  0.05). Inspiratory muscle training can improve pulmonary function, respiratory muscle strength and functional capacity in patients with atrial fibrillation. © The Author(s) 2016.

  8. Acute effects of inspiratory muscle warm-up on pulmonary function in healthy subjects.

    Science.gov (United States)

    Özdal, Mustafa

    2016-06-15

    The acute effects of inspiratory muscle warm-up on pulmonary functions were examined in 26 healthy male subjects using the pulmonary function test (PFT) in three different trials. The control trial (CON) did not involve inspiratory muscle warm-up, while the placebo (IMWp) and experimental (IMW) trials involved inspiratory muscle warm-up. There were no significant changes between the IMWp and CON trials (p>0.05). All the PFT measurements, including slow vital capacity, inspiratory vital capacity, forced vital capacity, forced expiratory volume in one second, maximal voluntary ventilation, and maximal inspiratory pressure were significantly increased by 3.55%, 12.52%, 5.00%, 2.75%, 2.66%, and 7.03% respectively, in the subjects in the IMW trial than those in the CON trial (pcooperation of the upper thorax, neck, and respiratory muscles, and increased level of reactive O2 species in muscle tissue, and potentially improvement of muscle O2 delivery-to-utilization. However, further investigation is required to determine the precise mechanisms responsible from among these candidates. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Reference values of inspiratory spirometry for Finnish adults.

    Science.gov (United States)

    Kainu, Annette; Timonen, Kirsi L; Vanninen, Esko; Sovijärvi, Anssi R

    2018-03-07

    Inspiratory spirometry is used in evaluation of upper airway disorders e.g. fixed or variable obstruction. There are, however, very few published data on normal values for inspiratory spirometry. The main aim of this study was to produce reference values for inspiratory spirometry for healthy Finnish adults. Inspiratory spirometry was preplanned to a sample of the Finnish spirometry reference values sample. Data was successfully retrieved from 368 healthy nonsmoking adults (132 males) between 19 and 83 years of age. Reference equations were produced for forced inspiratory vital capacity (FIVC), forced inspiratory volume in one second (FIV1), FIV1/FIVC, peak inspiratory flow (PIF) and the ratios of FIV1/forced expiratory volume in one second and PIF/peak expiratory flow. The present values were compared to PIF values from previously used Finnish study of Viljanen et al. (1982) reference values and Norwegian values for FIV1, FIVC and FIV1/FIVC presented by Gulsvik et al. (2001). The predicted values from the Gulsvik et al. (2001), provided a good fit for FIVC, but smaller values for FIV1 with mean 108.3 and 109.1% of predicted values for males and females, respectively. PIF values were 87.4 and 91.2% of Viljanen et al. (1982) predicted values in males and females, respectively. Differences in measurement methods and selection of results may contribute to the observed differences. Inspiratory spirometry is technically more demanding and needs repeatability criteria to improve validity. New reference values are suggested to clinical use in Finland when assessing inspiratory spirometry. Utility of inspiratory to expiratory values indices in assessment of airway collapse need further study.

  10. Nutritional status is related to fat-free mass, exercise capacity and inspiratory strength in severe chronic obstructive pulmonary disease patients

    Directory of Open Access Journals (Sweden)

    Pollyane Galinari Sabino

    2010-01-01

    Full Text Available INTRODUCTION: Being overweight or obese is associated with a higher rate of survival in patients with advanced chronic obstructive pulmonary disease (COPD. This paradoxical relationship indicates that the influence of nutritional status on functional parameters should be further investigated. OBJECTIVE: To investigate the impact of nutritional status on body composition, exercise capacity and respiratory muscle strength in severe chronic obstructive pulmonary disease patients. METHODS: Thirty-two patients (nine women were divided into three groups according to their body mass indices (BMI: overweight/obese (25 < BMI < 34.9 kg/m², n=8, normal weight (18.5 < BMI < 24.9 kg/m², n=17 and underweight (BMI <18.5 kg/m², n=7. Spirometry, bioelectrical impedance, a six-minute walking distance test and maximal inspiratory and expiratory pressures were assessed. RESULTS: Airway obstruction was similar among the groups (p=0.30; however, overweight/obese patients had a higher fat-free mass (FFM index [FFMI=FFM/body weight² (mean±SEM: 17±0.3 vs. 15±0.3 vs. 14±0.5 m/kg², p<0.01], exercise capacity (90±8 vs. 79±6 vs. 57±8 m, p=0.02 and maximal inspiratory pressure (63±7 vs. 57±5 vs. 35±8 % predicted, p=0.03 in comparison to normal weight and underweight patients, respectively. In addition, on backward multiple regression analysis, FFMI was the unique independent predictor of exercise capacity (partial r=0.52, p<0.01. CONCLUSIONS: Severe chronic obstructive pulmonary disease (COPD patients who were overweight or obese had a greater FFM, exercise capacity and inspiratory muscle strength than patients with the same degree of airflow obstruction who were of normal weight or underweight, and higher FFM was independently associated with higher exercise capacity. These characteristics of overweight or obese patients might counteract the drawbacks of excess weight and lead to an improved prognosis in COPD.

  11. Effects of inspiratory muscle training on dynamic hyperinflation in patients with COPD

    Directory of Open Access Journals (Sweden)

    Petrovic M

    2012-11-01

    Full Text Available Milos Petrovic,1 Michael Reiter,2 Harald Zipko,3 Wolfgang Pohl,1 Theodor Wanke11Pulmonary Department and Karl Landsteiner Institute for Clinical and Experimental Pulmology, Hietzing Hospital, Vienna, Austria; 2Department of Respiratory and Critical Care Medicine, Otto Wagner Hospital, Vienna, Austria; 3FH Campus Vienna, University of Applied Sciences – Health Department, Vienna, AustriaAbstract: Dynamic hyperinflation has important clinical consequences in patients with chronic obstructive pulmonary disease (COPD. Given that most of these patients have respiratory and peripheral muscle weakness, dyspnea and functional exercise capacity may improve as a result of inspiratory muscle training (IMT. The aim of the study was to analyze the effects of IMT on exercise capacity, dyspnea, and inspiratory fraction (IF during exercise in patients with COPD. Daily inspiratory muscle strength and endurance training was performed for 8 weeks in 10 patients with COPD GOLD II and III. Ten patients with COPD II and III served as a control group. Maximal inspiratory pressure (Pimax and endurance time during resistive breathing maneuvers (tlim served as parameter for inspiratory muscle capacity. Before and after training, the patients performed an incremental symptom limited exercise test to maximum and a constant load test on a cycle ergometer at 75% of the peak work rate obtained in the pretraining incremental test. ET was defined as the duration of loaded pedaling. Following IMT, there was a statistically significant increase in inspiratory muscle performance of the Pimax from 7.75 ± 0.47 to 9.15 ± 0.73 kPa (P < 0.01 and of tlim from 348 ± 54 to 467 ± 58 seconds (P < 0.01. A significant increase in IF, indicating decreased dynamic hyperinflation, was observed during both exercise tests. Further, the ratio of breathing frequency to minute ventilation (bf/V'E decreased significantly, indicating an improved breathing pattern. A significant decrease in

  12. Influence of heart failure on resting lung volumes in patients with COPD

    Science.gov (United States)

    de Souza, Aline Soares; Sperandio, Priscila Abreu; Mazzuco, Adriana; Alencar, Maria Clara; Arbex, Flávio Ferlin; de Oliveira, Mayron Faria; O'Donnell, Denis Eunan; Neder, José Alberto

    2016-01-01

    ABSTRACT Objective: To evaluate the influence of chronic heart failure (CHF) on resting lung volumes in patients with COPD, i.e., inspiratory fraction-inspiratory capacity (IC)/TLC-and relative inspiratory reserve-[1 − (end-inspiratory lung volume/TLC)]. Methods: This was a prospective study involving 56 patients with COPD-24 (23 males/1 female) with COPD+CHF and 32 (28 males/4 females) with COPD only-who, after careful clinical stabilization, underwent spirometry (with forced and slow maneuvers) and whole-body plethysmography. Results: Although FEV1, as well as the FEV1/FVC and FEV1/slow vital capacity ratios, were higher in the COPD+CHF group than in the COPD group, all major "static" volumes-RV, functional residual capacity (FRC), and TLC-were lower in the former group (p < 0.05). There was a greater reduction in FRC than in RV, resulting in the expiratory reserve volume being lower in the COPD+CHF group than in the COPD group. There were relatively proportional reductions in FRC and TLC in the two groups; therefore, IC was also comparable. Consequently, the inspiratory fraction was higher in the COPD+CHF group than in the COPD group (0.42 ± 0.10 vs. 0.36 ± 0.10; p < 0.05). Although the tidal volume/IC ratio was higher in the COPD+CHF group, the relative inspiratory reserve was remarkably similar between the two groups (0.35 ± 0.09 vs. 0.44 ± 0.14; p < 0.05). Conclusions: Despite the restrictive effects of CHF, patients with COPD+CHF have relatively higher inspiratory limits (a greater inspiratory fraction). However, those patients use only a part of those limits, probably in order to avoid critical reductions in inspiratory reserve and increases in elastic recoil. PMID:27832235

  13. Inspiratory flow pattern in humans.

    Science.gov (United States)

    Lafortuna, C L; Minetti, A E; Mognoni, P

    1984-10-01

    The theoretical estimation of the mechanical work of breathing during inspiration at rest is based on the common assumption that the inspiratory airflow wave is a sine function of time. Different analytical studies have pointed out that from an energetic point of view a rectangular wave is more economical than a sine wave. Visual inspection of inspiratory flow waves recorded during exercise in humans and various animals suggests that a trend toward a rectangular flow wave may be a possible systematic response of the respiratory system. To test this hypothesis, the harmonic content of inspiratory flow waves that were recorded in six healthy subjects at rest, during exercise hyperventilation, and during a maximum voluntary ventilation (MVV) maneuver were evaluated by a Fourier analysis, and the results were compared with those obtained on sinusoidal and rectangular models. The dynamic work inherent in the experimental waves and in the sine-wave model was practically the same at rest; during exercise hyperventilation and MVV, the experimental wave was approximately 16-20% more economical than the sinusoidal one. It was concluded that even though at rest the sinusoidal model is a reasonably good approximation of inspiratory flow, during exercise and MVV, a physiological controller is probably operating in humans that can select a more economical inspiratory pattern. Other peculiarities of airflow wave during hyperventilation and some optimization criteria are also discussed.

  14. Inspiratory muscle training in difficult to wean patients: work it harder, make it better, do it faster, makes us stronger.

    Science.gov (United States)

    Nava, Stefano; Fasano, Luca

    2011-01-01

    Weaning from prolonged mechanical ventilation is a complex, time-consuming process that involves the loss of force/generating capacity of the inspiratory muscle. In their study 'Inspiratory muscle strength training improves the outcome in failure to wean patients: a randomized trial', Martin and colleagues showed that the use of an inspiratory muscle strength program increased the maximal inspiratory pressure and improved weaning success compared to a control group. The study was performed mainly in post-surgical patients, however, and the results, therefore, may not be generalizable to other subsets of patients, such as those with chronic obstructive pulmonary disease or congestive heart failure. Indeed, the study applied so-called 'strength training' and not 'endurance training', which may be more appropriate in certain circumstances.

  15. Cycle ergometer and inspiratory muscle training offer modest benefit compared with cycle ergometer alone: a comprehensive assessment in stable COPD patients

    Directory of Open Access Journals (Sweden)

    Wang K

    2017-09-01

    Full Text Available Kai Wang,1,* Guang-qiao Zeng,2,* Rui Li,1,* Yu-wen Luo,1 Mei Wang,1 Yu-he Hu,1 Wen-hui Xu,1 Lu-qian Zhou,2 Rong-chang Chen,2 Xin Chen1 1Department of Respiratory Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, China; 2Department of Respiratory Medicine, The State Key Laboratory of Respiratory Disease, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Disease, First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China *These authors contributed equally to this work Background: Cycle ergometer training (CET has been shown to improve exercise performance of the quadriceps muscles in patients with COPD, and inspiratory muscle training (IMT may improve the pressure-generating capacity of the inspiratory muscles. However, the effects of combined CET and IMT remain unclear and there is a lack of comprehensive assessment.Materials and methods: Eighty-one patients with COPD were randomly allocated to three groups: 28 received 8 weeks of CET + IMT (combined training group, 27 received 8 weeks of CET alone (CET group, and 26 only received 8 weeks of free walking (control group. Comprehensive assessment including respiratory muscle strength, exercise capacity, pulmonary function, dyspnea, quality of life, emotional status, nutritional status, and body mass index, airflow obstruction, and exercise capacity index were measured before and after the pulmonary rehabilitation program.Results: Respiratory muscle strength, exercise capacity, inspiratory capacity, dyspnea, quality of life, depression and anxiety, and nutritional status were all improved in the combined training and CET groups when compared with that in the control group (P<0.05 after pulmonary rehabilitation program. Inspiratory muscle strength increased significantly in the combined training group when compared with that in the CET group (ΔPImax [maximal inspiratory pressure] 5.20±0.89 cmH2O vs 1.32±0.91 cmH2O

  16. Simulation of late inspiratory rise in airway pressure during pressure support ventilation.

    Science.gov (United States)

    Yu, Chun-Hsiang; Su, Po-Lan; Lin, Wei-Chieh; Lin, Sheng-Hsiang; Chen, Chang-Wen

    2015-02-01

    Late inspiratory rise in airway pressure (LIRAP, Paw/ΔT) caused by inspiratory muscle relaxation or expiratory muscle contraction is frequently seen during pressure support ventilation (PSV), although the modulating factors are unknown. We investigated the effects of respiratory mechanics (normal, obstructive, restrictive, or mixed), inspiratory effort (-2, -8, or -15 cm H2O), flow cycle criteria (5-40% peak inspiratory flow), and duration of inspiratory muscle relaxation (0.18-0.3 s) on LIRAP during PSV using a lung simulator and 4 types of ventilators. LIRAP occurred with all lung models when inspiratory effort was medium to high and duration of inspiratory muscle relaxation was short. The normal lung model was associated with the fastest LIRAP, whereas the obstructive lung model was associated with the slowest. Unless lung mechanics were normal or mixed, LIRAP was unlikely to occur when inspiratory effort was low. Different ventilators were also associated with differences in LIRAP speed. Except for within the restrictive lung model, changes in flow cycle level did not abolish LIRAP if inspiratory effort was medium to high. Increased duration of inspiratory relaxation also led to the elimination of LIRAP. Simulation of expiratory muscle contraction revealed that LIRAP occurred only when expiratory muscle contraction occurred sometime after the beginning of inspiration. Our simulation study reveals that both respiratory resistance and compliance may affect LIRAP. Except for under restrictive lung conditions, LIRAP is unlikely to be abolished by simply lowering flow cycle criteria when inspiratory effort is strong and relaxation time is rapid. LIRAP may be caused by expiratory muscle contraction when it occurs during inspiration. Copyright © 2015 by Daedalus Enterprises.

  17. Volume-monitored chest CT: a simplified method for obtaining motion-free images near full inspiratory and end expiratory lung volumes

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Kathryn S. [The Ohio State University College of Medicine, Columbus, OH (United States); Long, Frederick R. [Nationwide Children' s Hospital, The Children' s Radiological Institute, Columbus, OH (United States); Flucke, Robert L. [Nationwide Children' s Hospital, Department of Pulmonary Medicine, Columbus, OH (United States); Castile, Robert G. [The Research Institute at Nationwide Children' s Hospital, Center for Perinatal Research, Columbus, OH (United States)

    2010-10-15

    Lung inflation and respiratory motion during chest CT affect diagnostic accuracy and reproducibility. To describe a simple volume-monitored (VM) method for performing reproducible, motion-free full inspiratory and end expiratory chest CT examinations in children. Fifty-two children with cystic fibrosis (mean age 8.8 {+-} 2.2 years) underwent pulmonary function tests and inspiratory and expiratory VM-CT scans (1.25-mm slices, 80-120 kVp, 16-40 mAs) according to an IRB-approved protocol. The VM-CT technique utilizes instruction from a respiratory therapist, a portable spirometer and real-time documentation of lung volume on a computer. CT image quality was evaluated for achievement of targeted lung-volume levels and for respiratory motion. Children achieved 95% of vital capacity during full inspiratory imaging. For end expiratory scans, 92% were at or below the child's end expiratory level. Two expiratory exams were judged to be at suboptimal volumes. Two inspiratory (4%) and three expiratory (6%) exams showed respiratory motion. Overall, 94% of scans were performed at optimal volumes without respiratory motion. The VM-CT technique is a simple, feasible method in children as young as 4 years to achieve reproducible high-quality full inspiratory and end expiratory lung CT images. (orig.)

  18. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Inspiratory airway pressure meter. 868.1780 Section 868.1780 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the amount...

  19. Inspiratory time and tidal volume during intermittent positive pressure ventilation.

    OpenAIRE

    Field, D; Milner, A D; Hopkin, I E

    1985-01-01

    We measured the tidal volume achieved during intermittent positive pressure ventilation using various inspiratory times with a minimum of 0.2 seconds. Results indicate that tidal volume shows no reduction with inspiratory times down to 0.4 seconds. An inspiratory time of 0.3 seconds, however, is likely to reduce tidal volume by 8%, and at 0.2 seconds a 22% fall may be anticipated.

  20. Inspiratory muscle training in patients with Amyotrophic Lateral Sclerosis: A systematic review.

    Science.gov (United States)

    Eidenberger, Margit; Nowotny, Silvia

    2014-01-01

    Amyotrophic Lateral Sclerosis is a neurodegenerative disease with rapid involvement of the inspiratory muscles, leading to respiratory insufficiency. Death often occurs by aspiration and pneumonia. Endurance- and strength therapy within ALS are discussed controversially. To review the current literature to assess the efficacy of inspiratory muscle training for ALS. Systematic review, using databases as PubMed, PEDro, Cochrane and Google Scholar. Inspiratory muscle training vs. sham training or inspiratory muscle training alone. Inspiratory muscle strength, dyspnoea, quality of life and survival time. Four studies could be included in this review, two RCT's, one pre-experimental study and one with a historical control group. In total 73 patients underwent inspiratory muscle training. Studies varied in onset of the training, the training protocol and the outcomes measured. At time, there is limited evidence that inspiratory muscle training leads to strengthening of inspiratory muscles in ALS. Improvements made were minor, in only a few parameters and also in control groups. Survival time was significantly longer in the experimental group in one study. Interesting suppositions (diaphragm training vs. other IM training, improvement of chest wall and lung compliance) need to be examined in robustly designed future trials, defining exact therapeutic windows and interventions.

  1. Gap junctions and inhibitory synapses modulate inspiratory motoneuron synchronization.

    Science.gov (United States)

    Bou-Flores, C; Berger, A J

    2001-04-01

    Interneuronal electrical coupling via gap junctions and chemical synaptic inhibitory transmission are known to have roles in the generation and synchronization of activity in neuronal networks. Uncertainty exists regarding the roles of these two modes of interneuronal communication in the central respiratory rhythm-generating system. To assess their roles, we performed studies on both the neonatal mouse medullary slice and en bloc brain stem-spinal cord preparations where rhythmic inspiratory motor activity can readily be recorded from both hypoglossal and phrenic nerve roots. The rhythmic inspiratory activity observed had two temporal characteristics: the basic respiratory frequency occurring on a long time scale and the synchronous neuronal discharge within the inspiratory burst occurring on a short time scale. In both preparations, we observed that bath application of gap-junction blockers, including 18 alpha-glycyrrhetinic acid, 18 beta-glycyrrhetinic acid, and carbenoxolone, all caused a reduction in respiratory frequency. In contrast, peak integrated phrenic and hypoglossal inspiratory activity was not significantly changed by gap-junction blockade. On a short-time-scale, gap-junction blockade increased the degree of synchronization within an inspiratory burst observed in both nerves. In contrast, opposite results were observed with blockade of GABA(A) and glycine receptors. We found that respiratory frequency increased with receptor blockade, and simultaneous blockade of both receptors consistently resulted in a reduction in short-time-scale synchronized activity observed in phrenic and hypoglossal inspiratory bursts. These results support the concept that the central respiratory system has two components: a rhythm generator responsible for the production of respiratory cycle timing and an inspiratory pattern generator that is involved in short-time-scale synchronization. In the neonatal rodent, properties of both components can be regulated by interneuronal

  2. Diagnostic methods to assess inspiratory and expiratory muscle strength

    Directory of Open Access Journals (Sweden)

    Pedro Caruso

    2015-04-01

    Full Text Available Impairment of (inspiratory and expiratory respiratory muscles is a common clinical finding, not only in patients with neuromuscular disease but also in patients with primary disease of the lung parenchyma or airways. Although such impairment is common, its recognition is usually delayed because its signs and symptoms are nonspecific and late. This delayed recognition, or even the lack thereof, occurs because the diagnostic tests used in the assessment of respiratory muscle strength are not widely known and available. There are various methods of assessing respiratory muscle strength during the inspiratory and expiratory phases. These methods are divided into two categories: volitional tests (which require patient understanding and cooperation; and non-volitional tests. Volitional tests, such as those that measure maximal inspiratory and expiratory pressures, are the most commonly used because they are readily available. Non-volitional tests depend on magnetic stimulation of the phrenic nerve accompanied by the measurement of inspiratory mouth pressure, inspiratory esophageal pressure, or inspiratory transdiaphragmatic pressure. Another method that has come to be widely used is ultrasound imaging of the diaphragm. We believe that pulmonologists involved in the care of patients with respiratory diseases should be familiar with the tests used in order to assess respiratory muscle function.Therefore, the aim of the present article is to describe the advantages, disadvantages, procedures, and clinical applicability of the main tests used in the assessment of respiratory muscle strength.

  3. The effectiveness of combining inspiratory muscle training with manual therapy and a therapeutic exercise program on maximum inspiratory pressure in adults with asthma: a randomized clinical trial.

    Science.gov (United States)

    López-de-Uralde-Villanueva, Ibai; Candelas-Fernández, Pablo; de-Diego-Cano, Beatriz; Mínguez-Calzada, Orcález; Del Corral, Tamara

    2018-06-01

    The objective of this study was to evaluate whether the addition of manual therapy and therapeutic exercise protocol to inspiratory muscle training was more effective in improving maximum inspiratory pressure than inspiratory muscle training in isolation. This is a single-blinded, randomized controlled trial. In total, 43 patients with asthma were included in this study. The patients were allocated into one of the two groups: (1) inspiratory muscle training ( n = 21; 20-minute session) or (2) inspiratory muscle training (20-minute session) combined with a program of manual therapy (15-minute session) and therapeutic exercise (15-minute session; n = 22). All participants received 12 sessions, two days/week, for six weeks and performed the domiciliary exercises protocol. The main measures such as maximum inspiratory pressure, spirometric measures, forward head posture, and thoracic kyphosis were recorded at baseline and after the treatment. For the per-protocol analysis, between-group differences at post-intervention were observed in maximum inspiratory pressure (19.77 cmH 2 O (11.49-28.04), P < .05; F = 22.436; P < .001; η 2 p  = 0.371) and forward head posture (-1.25 cm (-2.32 to -0.19), P < .05; F = 5.662; P = .022; η 2 p  = 0.13). The intention-to-treat analysis showed the same pattern of findings. The inspiratory muscle training combined with a manual therapy and therapeutic exercise program is more effective than its application in isolation for producing short-term maximum inspiratory pressure and forward head posture improvements in patients with asthma.

  4. Reference Values for Maximal Inspiratory Pressure: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Isabela MB Sclauser Pessoa

    2014-01-01

    Full Text Available BACKGROUND: Maximal inspiratory pressure (MIP is the most commonly used measure to evaluate inspiratory muscle strength. Normative values for MIP vary significantly among studies, which may reflect differences in participant demographics and technique of MIP measurement.

  5. Specific inspiratory muscle warm-up enhances badminton footwork performance.

    Science.gov (United States)

    Lin, Hua; Tong, Tom Kwokkeung; Huang, Chuanye; Nie, Jinlei; Lu, Kui; Quach, Binh

    2007-12-01

    The effects of inspiratory muscle (IM) warm-up on IM function and on the maximum distance covered in a subsequent incremental badminton-footwork test (FWmax) were examined. Ten male badminton players were recruited to perform identical tests in three different trials in a random order. The control trial did not involve an IM warm-up, whereas the placebo and experimental trials did involve an IM warm-up consisting of two sets of 30-breath manoeuvres with an inspiratory pressure-threshold load equivalent to 15% (PLA) and 40% (IMW) maximum inspiratory mouth pressure, respectively. In the IMW trial, IM function was improved with 7.8%+/-4.0% and 6.9%+/-3.5% increases from control found in maximal inspiratory pressure at zero flow (P0) and maximal rate of P0 development (MRPD), respectively (pbadminton-footwork test. The improved footwork was partly attributable to the reduced breathless sensation resulting from the enhanced IM function, whereas the contribution of the concomitant reduction in [La-]b accumulation was relatively minor.

  6. Whole-lung volume and density in spirometrically-gated inspiratory and expiratory CT in systemic sclerosis: correlation with static volumes at pulmonary function tests.

    Science.gov (United States)

    Camiciottoli, G; Diciotti, S; Bartolucci, M; Orlandi, I; Bigazzi, F; Matucci-Cerinic, M; Pistolesi, M; Mascalchi, M

    2013-03-01

    Spiral low-dose computed tomography (LDCT) permits to measure whole-lung volume and density in a single breath-hold. To evaluate the agreement between static lung volumes measured with LDCT and pulmonary function test (PFT) and the correlation between the LDCT volumes and lung density in restrictive lung disease. Patients with Systemic Sclerosis (SSc) with (n = 24) and without (n = 16) pulmonary involvement on sequential thin-section CT and patients with chronic obstructive pulmonary disease (COPD)(n = 29) underwent spirometrically-gated LDCT at 90% and 10% of vital capacity to measure inspiratory and expiratory lung volumes and mean lung attenuation (MLA). Total lung capacity and residual volume were measured the same day of CT. Inspiratory [95% limits of agreement (95% LoA)--43.8% and 39.2%] and expiratory (95% LoA -45.8% and 37.1%) lung volumes measured on LDCT and PFT showed poor agreement in SSc patients with pulmonary involvement, whereas they were in substantial agreement (inspiratory 95% LoA -14.1% and 16.1%; expiratory 95% LoA -13.5% and 23%) in SSc patients without pulmonary involvement and in inspiratory scans only (95% LoA -23.1% and 20.9%) of COPD patients. Inspiratory and expiratory LDCT volumes, MLA and their deltas differentiated both SSc patients with or without pulmonary involvement from COPD patients. LDCT lung volumes and density were not correlated in SSc patients with pulmonary involvement, whereas they did correlate in SSc without pulmonary involvement and in COPD patients. In restrictive lung disease due to SSc there is poor agreement between static lung volumes measured using LDCT and PFT and the relationship between volume and density values on CT is altered.

  7. Immediate effect of manual therapy on respiratory functions and inspiratory muscle strength in patients with COPD

    Directory of Open Access Journals (Sweden)

    Yilmaz Yelvar GD

    2016-06-01

    Full Text Available Gul Deniz Yilmaz Yelvar,1 Yasemin Çirak,2 Yasemin Parlak Demir,3 Murat Dalkilinç,1 Bülent Bozkurt4 1Department of Musculoskeletal Physiotherapy, 2Department of Cardiopulmonary Physiotherapy, 3Department of Neurological Rehabilitation, School of Physiotherapy and Rehabilitation, 4Department of Respiratory Medicine, Faculty of Medicine, Turgut Özal University, Ankara, Turkey Objective: The objective of this study was to investigate the immediate effect of manual therapy (MT on respiratory functions and inspiratory muscle strength in patients with COPD.Participants and methods: Thirty patients with severe COPD (eight females and 22 males; mean age 62.4±6.8 years referred to pulmonary physiotherapy were included in this study. The patients participated in a single session of MT to measure the short-term effects. The lung function was measured using a portable spirometer. An electronic pressure transducer was used to measure respiratory muscle strength. Heart rate, breathing frequency, and oxygen saturation were measured with a pulse oximeter. For fatigue and dyspnea perception, the modified Borg rating of perceived exertion scale was used. All measurements were taken before and immediately after the first MT session. The ease-of-breathing visual analog scale was used for rating patients’ symptoms subjectively during the MT session.Results: There was a significant improvement in the forced expiratory volume in the first second, forced vital capacity, and vital capacity values (P<0.05. The maximal inspiratory pressure and maximal expiratory pressure values increased significantly after MT, compared to the pre-MT session (P<0.05. There was a significant decrease in heart rate, respiratory rate (P<0.05, and dyspnea and fatigue perception (P<0.05.Conclusion: A single MT session immediately improved pulmonary function, inspiratory muscle strength, and oxygen saturation and reduced dyspnea, fatigue, and heart and respiratory rates in patients with

  8. Lung volumes and maximal respiratory pressures in collegiate swimmers and runners.

    Science.gov (United States)

    Cordain, L; Tucker, A; Moon, D; Stager, J M

    1990-03-01

    To determine whether respiratory muscle strength is related to pulmonary volume differences in athletes and nonathletes, 11 intercollegiate female swimmers, 11 female cross-country runners, and two nonathletic control groups, matched to the athletes in height and age, were evaluated for pulmonary parameters including maximal inspiratory pressure (PImax) and maximal expiratory pressure (PEmax). Swimmers exhibited larger (p less than .05) vital capacities (VC), residual lung volumes (RV), inspiratory capacities (IC), and functional residual capacities (FRC) than both the runners or the controls but no difference (p greater than .05) in either PImax or inspiratory flow (FIV 25%-75%). Timed expiratory volumes (FEV 0.5 and FEV 1.0) were significantly (p less than .05) lower in the swimmers than in the controls. These data suggest that an adaptational growth may be responsible, in part, for the augmented static lung volumes demonstrated in swimmers.

  9. The effect of the inspiratory muscle training on functional ability in stroke patients.

    Science.gov (United States)

    Jung, Nam-Jin; Na, Sang-Su; Kim, Seung-Kyu; Hwangbo, Gak

    2017-11-01

    [Purpose] This study was to find out an inspiratory muscle training (IMT) program therapeutic effects on stroke patients' functional ability. [Subjects and Methods] Twenty stroke patients were assigned to one of two groups: inspiratory muscle training (n=10), and control (n=10), randomization. The inspiratory muscle training participants undertook an exercise program for 30 minute per times, 5 times a week for 6 weeks. The investigator measured the patients' trunk impairment scale (TIS) and 6 minute walking test (6MW) for functional ability before and after IMT. [Results] The TIS appeared some significant differences in both groups before and after the training. The 6MW test showed some significant differences in the inspiratory muscle training group, but didn't show any significant difference in the control group. And the differences in both groups after depending the inspiratory muscle training were significantly found in the tests of TIS and 6MW test [Conclusion] The results showed that the inspiratory muscle training in stroke patients are correlated with the trunk stability and locomotion ability, suggesting that physical therapist must take into consideration the inspiratory muscle training, as well as functional training to improve physical function in stroke patients.

  10. "Functional" Inspiratory and Core Muscle Training Enhances Running Performance and Economy.

    Science.gov (United States)

    Tong, Tomas K; McConnell, Alison K; Lin, Hua; Nie, Jinlei; Zhang, Haifeng; Wang, Jiayuan

    2016-10-01

    Tong, TK, McConnell, AK, Lin, H, Nie, J, Zhang, H, and Wang, J. "Functional" inspiratory and core muscle training enhances running performance and economy. J Strength Cond Res 30(10): 2942-2951, 2016-We compared the effects of two 6-week high-intensity interval training interventions. Under the control condition (CON), only interval training was undertaken, whereas under the intervention condition (ICT), interval training sessions were followed immediately by core training, which was combined with simultaneous inspiratory muscle training (IMT)-"functional" IMT. Sixteen recreational runners were allocated to either ICT or CON groups. Before the intervention phase, both groups undertook a 4-week program of "foundation" IMT to control for the known ergogenic effect of IMT (30 inspiratory efforts at 50% maximal static inspiratory pressure [P0] per set, 2 sets per day, 6 days per week). The subsequent 6-week interval running training phase consisted of 3-4 sessions per week. In addition, the ICT group undertook 4 inspiratory-loaded core exercises (10 repetitions per set, 2 sets per day, inspiratory load set at 50% post-IMT P0) immediately after each interval training session. The CON group received neither core training nor functional IMT. After the intervention phase, global inspiratory and core muscle functions increased in both groups (p ≤ 0.05), as evidenced by P0 and a sport-specific endurance plank test (SEPT) performance, respectively. Compared with CON, the ICT group showed larger improvements in SEPT, running economy at the speed of the onset of blood lactate accumulation, and 1-hour running performance (3.04% vs. 1.57%, p ≤ 0.05). The changes in these variables were interindividually correlated (r ≥ 0.57, n = 16, p ≤ 0.05). Such findings suggest that the addition of inspiratory-loaded core conditioning into a high-intensity interval training program augments the influence of the interval program on endurance running performance and that this may be

  11. Inspiratory muscle training in bronchiectasis patients: a prospective randomized controlled study.

    Science.gov (United States)

    Liaw, Mei-Yun; Wang, Yi-Hsi; Tsai, Yu-Chin; Huang, Kuo-Tung; Chang, Pei-Wen; Chen, Yung-Che; Lin, Meng-Chih

    2011-06-01

    To investigate the efficacy and feasibility of home-based inspiratory muscle training in patients with bronchiectasis. A prospective, single-blind, randomized, controlled study. Outpatient clinic of a tertiary care medical centre. Twenty-six patients with bronchiectasis were randomly divided into inspiratory muscle training and control groups. In the inspiratory muscle training group (n = 13), the training programme started with an intensity of 30% maximal inspiratory pressure (MIP), which was increased by 2 cmH(2)O each week, for 30 minutes daily, 5 days a week for eight weeks. The control group (n = 13) did not receive inspiratory muscle training. Main outcome measures included spirometry, resting oxyhaemoglobin saturation by pulse oximetry (SpO(2)), lowest SpO(2) and Borg Scale during 6-minute walking tests, 6-minute walking distance (6MWD), 6-minute walking work (6M(work)), MIP, maximal expiratory pressure (MEP) and St George's Respiratory Questionnaire. There were significant differences in change from baseline in 6MWD (411.9 (133.5) vs. 473.2 (117.2) m, P = 0.021), 6M(work) (21 051.0 (8286.7) vs. 23 915.5 (8343.0) kg-m, P = 0.022), MIP (60.8 (21.8) vs. 84.6 (29.0) cmH(2)O, P = 0.004), and MEP (72.3 (31.1) vs. 104.2 (35.7) cmH(2)O, P = 0.004) in the inspiratory muscle training group. Significant improvements in both MIP (23.8 (25.3) vs. 2.3 (16.4) cmH(2)O, adjusted P-value = 0.005) and MEP (31.9 (30.8) vs. 11.5 (20.8) cmH(2)O, adjusted P-value = 0.038) levels after adjusting for age by linear regression analysis were observed between groups. An eight-week home-based inspiratory muscle training is feasible and effective in improving both inspiratory and expiratory muscle strength, but has no effect on respiratory function and quality of life in patients with bronchiectasis.

  12. Inspiratory and expiratory HRCT findings in healthy smokers' lung

    International Nuclear Information System (INIS)

    Park, Hyeon Seon; Kwak, Byung Kook; Choi, Chi Hoon; Yang, Keun Mung; Lee, Chang Joon; Joo, Dong Il; Kim, Yang Soo

    1998-01-01

    The purpose of this study is to evaluate the lung changes in healthy smokers, as seen on inspiratory and expiratory high-resolution computed tomography (HRCT). Twenty-seven healthy smokers (light smokers, below 20 pack-years, n=16; heavy smokers, above 20 pack-years, n=11) and 25 nonsmokers underwent inspiratory and expiratory HRCT. All healthy smokers had normal pulmonary function and chest radiography. Parenchymal and subpleural micronodules, ground-glass attenuation, centrilobular and paraseptal emphysema, bronchial wall thickening, bronchiectasis and septal line were evaluated on inspiratory scan and by air-trapping on expiratory scan. According to the findings of HRCT, heavy smokers and higher frequency of parenchymal micronodules, ground-glass attenuation, centrilobular and paraseptal emphysema, and air-trapping than nonsmokers and light smokers. (author). 13 refs., 1 tab., 4 figs

  13. Dendritic calcium activity precedes inspiratory bursts in preBotzinger complex neurons

    DEFF Research Database (Denmark)

    Del Negro, Christopher A; Hayes, John A; Rekling, Jens C

    2011-01-01

    to evoke a Ca(2+)-activated inward current that contributes to inspiratory burst generation. We measured Ca(2+) transients by two-photon imaging dendrites while recording neuronal somata electrophysiologically. Dendritic Ca(2+) accumulation frequently precedes inspiratory bursts, particularly at recording...

  14. Effect of inspiratory muscle training with load compared with sham training on blood pressure in individuals with hypertension: study protocol of a double-blind randomized clinical trial.

    Science.gov (United States)

    Posser, Simone Regina; Callegaro, Carine Cristina; Beltrami-Moreira, Marina; Moreira, Leila Beltrami

    2016-08-02

    Hypertension is a complex chronic condition characterized by elevated arterial blood pressure. Management of hypertension includes non-pharmacologic strategies, which may include techniques that effectively reduce autonomic sympathetic activity. Respiratory exercises improve autonomic control over cardiovascular system and attenuate muscle metaboreflex. Because of these effects, respiratory exercises may be useful to lower blood pressure in subjects with hypertension. This randomized, double-blind clinical trial will test the efficacy of inspiratory muscle training in reducing blood pressure in adults with essential hypertension. Subjects are randomly allocated to intervention or control groups. Intervention consists of inspiratory muscle training loaded with 40 % of maximum inspiratory pressure, readjusted weekly. Control sham intervention consists of unloaded exercises. Systolic and diastolic blood pressures are co-primary endpoint measures assessed with 24 h ambulatory blood pressure monitoring. Secondary outcome measures include cardiovascular autonomic control, inspiratory muscle metaboreflex, cardiopulmonary capacity, and inspiratory muscle strength and endurance. Previously published work suggests that inspiratory muscle training reduces blood pressure in persons with hypertension, but the effectiveness of this intervention is yet to be established. We propose an adequately sized randomized clinical trial to test this hypothesis rigorously. If an effect is found, this study will allow for the investigation of putative mechanisms to mediate this effect, including autonomic cardiovascular control and metaboreflex. ClinicalTrials.gov NCT02275377 . Registered on 30 September 2014.

  15. CPAP and EPAP elicit similar lung deflation in a non-equivalent mode in GOLD 3-4 COPD patients.

    Science.gov (United States)

    Müller, Paulo de Tarso; Christofoletti, Gustavo; Koch, Rodrigo; Zardetti Nogueira, João Henrique; Patusco, Luiz Armando Pereira; Chiappa, Gaspar Rogério

    2018-04-01

    Lung hyperinflation is associated with inspiratory muscle strength reduction, nocturnal desaturation, dyspnea, altered cardiac function and poor exercise capacity in advanced COPD. We investigated the responses of inspiratory capacity (IC) and inspiratory muscle strength (PImax), comparing continuous positive airway pressure (CPAP) and expiratory positive airway pressure (EPAP) with the main hypothesis that there would be similar effects on lung deflation. Eligible patients were submitted to 10 cmH 2 O CPAP and EPAP on different days, under careful ECG (HR) and peripheral oxygen saturation (SpO 2 ) monitoring. Twenty-one eligible COPD patients were studied (13 male/8 female, FEV 1 % predicted of 36.5 ± 9.8). Both CPAP and EPAP demonstrated significant post-pre (Δ) changes for IC and PImax, with mean ΔIC for CPAP and EPAP of 200 ± 100 mL and 170 ± 105 mL (P = .001 for both) in 13 and 12 patients (responders) respectively. There were similar changes in % predicted IC and PImax (∼7%, P = .001 for both) for responders and poor responder/non-responder agreement depending on CPAP/EPAP mode (Kappa = .113, P = .604). There were no differences in CPAP and EPAP regarding intensity of lung deflation (P =.254) and no difference was measured regarding HR (P = .235) or SpO 2 (P = .111) . CONCLUSIONS: Both CPAP and EPAP presented a similar effect on lung deflation, without guaranteeing that the response to one modality would be predictive of the response to the other. © 2017 John Wiley & Sons Ltd.

  16. Comparing the effects of rise time and inspiratory cycling criteria on 6 different mechanical ventilators.

    Science.gov (United States)

    Gonzales, Joshua F; Russian, Christopher J; Gregg Marshall, S; Collins, Kevin P

    2013-03-01

    Inspiratory rise time and cycling criteria are important settings in pressure support ventilation. The purpose of this study was to investigate the impact of minimum and maximum rise time and inspiratory cycling criteria settings on 6 new generation ventilators. Our hypothesis was there would be a difference in the exhaled tidal volume, inspiratory time, and peak flow among 6 different ventilators, based, on change in rise time and cycling criteria. The research utilized a breathing simulator and 4 different ventilator models. All mechanical ventilators were set to a spontaneous mode of ventilation with settings of pressure support 8 cm H2O and PEEP of 5 cm H2O. A minimum and maximum setting for rise time and cycling criteria were examined. Exhaled tidal volume, inspiratory time, and peak flow measurements were recorded for each simulation. Significant (P ventilator. Significant differences in exhaled tidal volume, inspiratory time, and peak flow were observed by adjusting rise time and cycling criteria. This research demonstrates that during pressure support ventilation strategy, adjustments in rise time and/or cycling criteria can produce changes in inspiratory parameters. Obviously, this finding has important implications for practitioners who utilize a similar pressure support strategy when conducting a ventilator wean. Additionally, this study outlines major differences among ventilator manufacturers when considering inspiratory rise time and cycling criteria.

  17. Increased inspiratory pressure for reduction of atelectasis in children anesthetized for CT scan

    International Nuclear Information System (INIS)

    Sargent, Michael A.; Jamieson, Douglas H.; McEachern, Anita M.; Blackstock, Derek

    2002-01-01

    Background: Atelectasis is more frequent and more severe in children anesthetized for CT scan than it is in children sedated for CT scan.Objective: To determine the effect of increased inspiratory pressure on atelectasis during chest CT in anesthetized children. Materials and methods: Atelectasis on chest CT was assessed by two observers in three groups of patients. Group A comprised 13 children (26 lungs) anesthetized at inspiratory pressures up to and including 25 cm H 2 O. Group B included 11 children anesthetized at inspiratory pressures ≥30 cm H 2 O. Group C included 8 children under deep sedation. Results: Atelectasis was significantly more severe in group A than in groups B and C. There was no significant difference between groups B and C. Conclusion: An inspiratory pressure of 30 cm H 2 O is recommended for children anesthetized for CT scan of the chest. (orig.)

  18. Functional Magnetic Stimulation of Inspiratory and Expiratory Muscles in Subjects With Tetraplegia.

    Science.gov (United States)

    Zhang, Xiaoming; Plow, Ela; Ranganthan, Vinoth; Huang, Honglian; Schmitt, Melissa; Nemunaitis, Gregory; Kelly, Clay; Frost, Frederick; Lin, Vernon

    2016-07-01

    Respiratory complications are major causes of morbidity and mortality in persons with a spinal cord injury, partly because of respiratory muscle paralysis. Earlier investigation has demonstrated that functional magnetic stimulation (FMS) can be used as a noninvasive technology for activating expiratory muscles, thus producing useful expiratory functions (simulated cough) in subjects with spinal cord injury. To evaluate the effectiveness of FMS for conditioning inspiratory and expiratory muscles in persons with tetraplegia. A prospective before and after trial. FMS Laboratory, Louis Stokes Cleveland VA Medical Center, Cleveland, OH. Six persons with tetraplegia. Each subject participated in a 6-week FMS protocol for conditioning the inspiratory and expiratory muscles. A magnetic stimulator was used with the center of a magnetic coil placed at the C7-T1 and T9-T10 spinous processes, respectively. Pulmonary function tests were performed before, during, and after the protocol. Respiratory variables included maximal inspiratory pressure (MIP), inspiratory reserve volume (IRV), peak inspiratory flow (PIF), maximal expiratory pressure (MEP), expiratory reserve volume (ERV), and peak expiratory flow (PEF). After 6 weeks of conditioning, the main outcome measurements (mean ± standard error) were as follows: MIP, 89.6 ± 7.3 cm H2O; IRV, 1.90 ± 0.34 L; PIF, 302.4 ± 36.3 L/min; MEP, 67.4 ± 11.1 cm H2O; ERV, 0.40 ± 0.06 L; and PEF, 372.4 ± 31.9 L/min. These values corresponded to 117%, 107%, 136%, 109%, 130%, and 124% of pre-FMS conditioning values, respectively. Significant improvements were observed in MIP (P = .022), PIF (P = .0001), and PEF (P = .0006), respectively. When FMS was discontinued for 4 weeks, these values showed decreases from their values at the end of the conditioning protocol, which suggests that continual FMS may be necessary to maintain improved respiratory functions. FMS conditioning of the inspiratory and expiratory muscles improved

  19. Spirometry, Static Lung Volumes, and Diffusing Capacity.

    Science.gov (United States)

    Vaz Fragoso, Carlos A; Cain, Hilary C; Casaburi, Richard; Lee, Patty J; Iannone, Lynne; Leo-Summers, Linda S; Van Ness, Peter H

    2017-09-01

    Spirometric Z-scores from the Global Lung Initiative (GLI) rigorously account for age-related changes in lung function and are thus age-appropriate when establishing spirometric impairments, including a restrictive pattern and air-flow obstruction. However, GLI-defined spirometric impairments have not yet been evaluated regarding associations with static lung volumes (total lung capacity [TLC], functional residual capacity [FRC], and residual volume [RV]) and gas exchange (diffusing capacity). We performed a retrospective review of pulmonary function tests in subjects ≥40 y old (mean age 64.6 y), including pre-bronchodilator measures for: spirometry ( n = 2,586), static lung volumes by helium dilution with inspiratory capacity maneuver ( n = 2,586), and hemoglobin-adjusted single-breath diffusing capacity ( n = 2,508). Using multivariable linear regression, adjusted least-squares means (adj LS Means) were calculated for TLC, FRC, RV, and hemoglobin-adjusted single-breath diffusing capacity. The adj LS Means were expressed with and without height-cubed standardization and stratified by GLI-defined spirometry, including normal ( n = 1,251), restrictive pattern ( n = 663), and air-flow obstruction (mild, [ n = 128]; moderate, [ n = 150]; and severe, [ n = 394]). Relative to normal spirometry, restrictive-pattern had lower adj LS Means for TLC, FRC, RV, and hemoglobin-adjusted single-breath diffusing capacity ( P ≤ .001). Conversely, relative to normal spirometry, mild, moderate, and severe air-flow obstruction had higher adj LS Means for FRC and RV ( P < .001). However, only mild and moderate air-flow obstruction had higher adj LS Means for TLC ( P < .001), while only moderate and severe air-flow obstruction had higher adj LS Means for RV/TLC ( P < .001) and lower adj LS Means for hemoglobin-adjusted single-breath diffusing capacity ( P < .001). Notably, TLC (calculated as FRC + inspiratory capacity) was not increased in severe air-flow obstruction ( P ≥ .11

  20. Exercise-induced inspiratory symptoms in school children

    DEFF Research Database (Denmark)

    Buchvald, Frederik; Phillipsen, Lue Drasbaek; Hjuler, Thomas

    2016-01-01

    BACKGROUND AND AIMS: Exercise-induced inspiratory symptoms (EIIS) have multiple causes, one of which is exercise-induced laryngeal obstruction (EILO). There is limited knowledge regarding EIIS in children, both in primary care practices and in pediatric asthma clinics. The aim of this study was t...

  1. Influence of inspiratory resistance on performance during graded exercise tests on a cycle ergometer

    NARCIS (Netherlands)

    Heus, R.; Hartog, E.A. den; Kistemaker, L.J.A.; Dijk, W.J. van; Swenker, G.

    2004-01-01

    Due to more stringent requirements to protect personnel against hazardous gasses, the inspiratory resistance of the present generation of respiratory protective devices tends to increase. Therefore an important question is to what extent inspiratory resistance may increase without giving problems

  2. Systematic Review of Inspiratory Muscle Training After Cerebrovascular Accident.

    Science.gov (United States)

    Martín-Valero, Rocío; De La Casa Almeida, Maria; Casuso-Holgado, Maria Jesus; Heredia-Madrazo, Alfonso

    2015-11-01

    This systematic review examines levels of evidence and recommendation grades of various therapeutic interventions of inspiratory muscle training in people who have had a stroke. Benefits from different levels of force and resistance in respiratory muscles are shown in this population. This review was conducted following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) directives and was completed in November 2014. The search limits were studies published in English between 2004 and 2014. Relevant studies were searched for in MEDLINE, PEDro, OAIster, Scopus, PsycINFO, Web of Knowledge, CINAHL, SPORTDiscus, DOAJ, Cochrane, Embase, Academic Search Complete, Fuente Académica, and MedicLatina. Initially, 20 articles were identified. After analyzing all primary documents, 14 studies were excluded. Only 6 studies were relevant to this review. Three different types of interventions were found (maximum inspiratory training, controlled training, and nonintervention) in 3 different groups. One specific study compared 3 inspiratory muscle training groups with a group of breathing exercises (diaphragmatic exercises with pursed lips) and a control group. Future long-term studies with larger sample sizes are needed. It is necessary to apply respiratory muscle training as a service of the national health system and to consider its inclusion in the conventional neurological program. Copyright © 2015 by Daedalus Enterprises.

  3. Learning to breathe? Feedforward regulation of the inspiratory motor drive.

    Science.gov (United States)

    Zaman, Jonas; Van den Bergh, Omer; Fannes, Stien; Van Diest, Ilse

    2014-09-15

    Claims have been made that breathing is in part controlled by feedforward regulation. In a classical conditioning paradigm, we investigated anticipatory increases in the inspiratory motor drive as measured by inspiratory occlusion pressure (P100). In an acquisition phase, an experimental group (N=13) received a low-intensity resistive load (5 cmH2O/l/s) for three consecutive inspirations as Conditioned Stimulus (CS), preceding a load of a stronger intensity (20 cmH2O/l/s) for three subsequent inspirations as unconditioned stimulus (US). The control group (N=11) received the low-intensity load for six consecutive inspirations. In a post-acquisition phase both groups received the low-intensity load for six consecutive inspirations. Responses to the CS-load only differed between groups during the first acquisition trials and a strong increase in P100 during the US-loads was observed, which habituated across the experiment. Our results suggest that the disruption caused by adding low to moderate resistive loads to three consecutive inspirations results in a short-lasting anticipatory increase in inspiratory motor drive. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Inspiratory and expiratory computed tomographic volumetry for lung volume reduction surgery.

    Science.gov (United States)

    Morimura, Yuki; Chen, Fengshi; Sonobe, Makoto; Date, Hiroshi

    2013-06-01

    Three-dimensional (3D) computed tomographic (CT) volumetry has been introduced into the field of thoracic surgery, and a combination of inspiratory and expiratory 3D-CT volumetry provides useful data on regional pulmonary function as well as the volume of individual lung lobes. We report herein a case of a 62-year-old man with severe emphysema who had undergone lung volume reduction surgery (LVRS) to assess this technique as a tool for the evaluation of regional lung function and volume before and after LVRS. His postoperative pulmonary function was maintained in good condition despite a gradual slight decrease 2 years after LVRS. This trend was also confirmed by a combination of inspiratory and expiratory 3D-CT volumetry. We confirm that a combination of inspiratory and expiratory 3D-CT volumetry might be effective for the preoperative assessment of LVRS in order to determine the amount of lung tissue to be resected as well as for postoperative evaluation. This novel technique could, therefore, be used more widely to assess local lung function.

  5. The influence of inspiratory effort and emphysema on pulmonary nodule volumetry reproducibility.

    Science.gov (United States)

    Moser, J B; Mak, S M; McNulty, W H; Padley, S; Nair, A; Shah, P L; Devaraj, A

    2017-11-01

    To evaluate the impact of inspiratory effort and emphysema on reproducibility of pulmonary nodule volumetry. Eighty-eight nodules in 24 patients with emphysema were studied retrospectively. All patients had undergone volumetric inspiratory and end-expiratory thoracic computed tomography (CT) for consideration of bronchoscopic lung volume reduction. Inspiratory and expiratory nodule volumes were measured using commercially available software. Local emphysema extent was established by analysing a segmentation area extended circumferentially around each nodule (quantified as percent of lung with density of -950 HU or less). Lung volumes were established using the same software. Differences in inspiratory and expiratory nodule volumes were illustrated using the Bland-Altman test. The influences of percentage reduction in lung volume at expiration, local emphysema extent, and nodule size on nodule volume variability were tested with multiple linear regression. The majority of nodules (59/88 [67%]) showed an increased volume at expiration. Mean difference in nodule volume between expiration and inspiration was +7.5% (95% confidence interval: -24.1, 39.1%). No relationships were demonstrated between nodule volume variability and emphysema extent, degree of expiration, or nodule size. Expiration causes a modest increase in volumetry-derived nodule volumes; however, the effect is unpredictable. Local emphysema extent had no significant effect on volume variability in the present cohort. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  6. Inspiratory muscle training is used in some intensive care units, but many training methods have uncertain efficacy: a survey of French physiotherapists

    Directory of Open Access Journals (Sweden)

    Tristan Bonnevie

    2015-10-01

    Full Text Available Questions: How common is inspiratory muscle training by physiotherapists in the intensive care unit (ICU? Which patients receive the training? What methods are used to administer the training? Is maximal inspiratory pressure used to evaluate the need for the training and the patient's outcome after training? Design: Cross-sectional survey of all ICUs in France. Participants: Two hundred and sixty-five senior physiotherapists. Results: The response rate was 99% among eligible units. Therapist experience in ICU was significantly associated with the use of inspiratory muscle training (p = 0.02. Therapists mainly used inspiratory muscle training either systematically or specifically in patients who failed to wean from mechanical ventilation. The training was used significantly more in non-sedated patients (p < 0.0001. The most commonly nominated technique that respondents claimed to use to apply the training was controlled diaphragmatic breathing (83% of respondents, whereas 13% used evidence-based methods. Among those who applied some form of inspiratory muscle training, 16% assessed maximal inspiratory pressure. Six respondents (2%, 95% CI 1 to 5 used both an evidence-based method to administer inspiratory muscle training and the recommended technique for assessment of inspiratory muscle strength. Conclusion: Most physiotherapists in French ICUs who apply inspiratory muscle training use methods of uncertain efficacy without assessment of maximal inspiratory pressure. Further efforts need to be made in France to disseminate information regarding evidence-based assessment and techniques for inspiratory muscle training in the ICU. The alignment of inspiratory muscle training practice with evidence could be investigated in other regions. [Bonnevie T, Villiot-Danger J-C, Gravier F-E, Dupuis J, Prieur G, Médrinal C (2015 Inspiratory muscle training is used in some intensive care units, but many training methods have uncertain efficacy: a survey of

  7. A five-week-old girl with inspiratory stridor due to infantile hemangiopericytoma

    DEFF Research Database (Denmark)

    Hansen, Jonas K; Sørensen, Flemming Brandt; Christensen, Mogens Fjord

    2006-01-01

    UNLABELLED: A 5-week-old girl with inspiratory stridor is presented. No immediate cause of the stridor was found, but eventually a diagnosis of infantile hemangiopericytoma located in the rhinopharynx was made. After surgery all respiratory symptoms disappeared.CONCLUSION: Infantile hemangioperic......UNLABELLED: A 5-week-old girl with inspiratory stridor is presented. No immediate cause of the stridor was found, but eventually a diagnosis of infantile hemangiopericytoma located in the rhinopharynx was made. After surgery all respiratory symptoms disappeared.CONCLUSION: Infantile...

  8. Weighted Polynomial Approximation for Automated Detection of Inspiratory Flow Limitation

    Directory of Open Access Journals (Sweden)

    Sheng-Cheng Huang

    2017-01-01

    Full Text Available Inspiratory flow limitation (IFL is a critical symptom of sleep breathing disorders. A characteristic flattened flow-time curve indicates the presence of highest resistance flow limitation. This study involved investigating a real-time algorithm for detecting IFL during sleep. Three categories of inspiratory flow shape were collected from previous studies for use as a development set. Of these, 16 cases were labeled as non-IFL and 78 as IFL which were further categorized into minor level (20 cases and severe level (58 cases of obstruction. In this study, algorithms using polynomial functions were proposed for extracting the features of IFL. Methods using first- to third-order polynomial approximations were applied to calculate the fitting curve to obtain the mean absolute error. The proposed algorithm is described by the weighted third-order (w.3rd-order polynomial function. For validation, a total of 1,093 inspiratory breaths were acquired as a test set. The accuracy levels of the classifications produced by the presented feature detection methods were analyzed, and the performance levels were compared using a misclassification cobweb. According to the results, the algorithm using the w.3rd-order polynomial approximation achieved an accuracy of 94.14% for IFL classification. We concluded that this algorithm achieved effective automatic IFL detection during sleep.

  9. Inspirometria de incentivo e breath stacking: repercussões sobre a capacidade inspiratória em indivíduos submetidos à cirurgia abdominal Incentive spirometry and breath stacking: effects on the inspiratory capacity of individuals submitted to abdominal surgery

    Directory of Open Access Journals (Sweden)

    CM Dias

    2008-04-01

    it is necessary to know which therapeutic approaches are the best ones to implement. OBJECTIVE: To compare the inspiratory volume during the breath stacking maneuver with the volume during incentive spirometry, in abdominal surgery patients. METHODS: Twelve patients, on their first postoperative day, were instructed to take a deep breath through the VoldyneTM incentive spirometer and to make successive inspiratory efforts using a facemask that had been adapted for performing the breath stacking maneuver. Each technique was performed five times according to the randomization. Before the operation, the patients performed a spirometric test. They were also assessed and instructed about the procedures. A WrightTM ventilometer allowed inspiratory capacity to be recorded. RESULTS: The inspiratory capacity during breath stacking was significantly higher than during incentive spirometry, both before and after the operation. There was a significant reduction in volumes after the surgical procedure, independent of the technique performed. CONCLUSIONS: The breath stacking technique was shown to be effective. This technique was better than incentive spirometry for generating and sustaining inspiratory volumes. Since no adverse effects have been described, this technique can probably be used safely and effectively, particularly in uncooperative patients.

  10. Inspiratory Muscle Training and Arterial Blood Oxygen Saturation in Patients With Chronic Obstructive Pulmonary Disease

    Directory of Open Access Journals (Sweden)

    Bakhshandeh Bavarsad

    2015-01-01

    Full Text Available Background One of the problems of the patients with chronic obstructive pulmonary disease (COPD is the weakness of the respiratory muscles that causes oxygen desaturation at rest and activity and decreases exercise tolerance. Objectives This study aimed to investigate the effect of inspiratory muscle training on arterial oxygen saturation (SPO2. Patients and Methods Forty patients with mild to very severe COPD were recruited for this study, which is a randomized control trail. The patients were randomized to IMT (inspiratory muscle training and control group. Training was performed with Respivol (a kind of inspiratory muscle trainer for 8 weeks (15 min/d for 6 d/week. SPSS software version 16 was used to analyze the data by performing independent t test, paired t test, and Fisher exact test. Results Results showed that, after 8 weeks of inspiratory muscle training, there was a little increase (but not statistically significant improvement in SPO2 (from 92.6 ± 8.71 % to 95.13 ± 7.08 %, with P = 0.06, whereas it remained unchanged in the control group (from 96.0 ± 3.46 % to 96.4 ± 3.35 % with P = 0.51. No statistically significant difference was seen between the two groups (P > 0.05. Conclusions Although inspiratory muscles training can prevent desaturation, which is caused by activity, it fails to improve it.

  11. [Exercise-induced inspiratory stridor. An important differential diagnosis of exercise-induced asthma].

    Science.gov (United States)

    Christensen, Pernille; Thomsen, Simon Francis; Rasmussen, Niels; Backer, Vibeke

    2007-11-19

    Recent studies suggest that exercise-induced inspiratory stridor (EIIS) is an important and often overlooked differential diagnosis of exercise-induced asthma. EIIS is characterised by astma-like symptoms, but differs by inspiratory limitation, fast recovery, and a lack of effect of inhaled bronchodilators. The prevalence of EIIS is reported to be 5-27%, and affects both children and adults. The pathophysiology, the pathogenesis, and the treatment of the condition are not yet clarified. At present, a population-based study is being conducted in order to address these points.

  12. Absence of inspiratory laryngeal constrictor muscle activity during nasal neurally adjusted ventilatory assist in newborn lambs.

    Science.gov (United States)

    Hadj-Ahmed, Mohamed Amine; Samson, Nathalie; Bussières, Marie; Beck, Jennifer; Praud, Jean-Paul

    2012-07-01

    In nonsedated newborn lambs, nasal pressure support ventilation (nPSV) can lead to an active glottal closure in early inspiration, which can limit lung ventilation and divert air into the digestive system, with potentially deleterious consequences. During volume control ventilation (nVC), glottal closure is delayed to the end of inspiration, suggesting that it is reflexly linked to the maximum value of inspiratory pressure. Accordingly, the aim of the present study was to test whether inspiratory glottal closure develops at the end of inspiration during nasal neurally adjusted ventilatory assist (nNAVA), an increasingly used ventilatory mode where maximal pressure is also reached at the end of inspiration. Polysomnographic recordings were performed in eight nonsedated, chronically instrumented lambs, which were ventilated with progressively increasing levels of nPSV and nNAVA in random order. States of alertness, diaphragm, and glottal muscle electrical activity, tracheal pressure, Spo(2), tracheal Pet(CO(2)), and respiratory inductive plethysmography were continuously recorded. Although phasic inspiratory glottal constrictor electrical activity appeared during nPSV in 5 of 8 lambs, it was never observed at any nNAVA level in any lamb, even at maximal achievable nNAVA levels. In addition, a decrease in Pco(2) was neither necessary nor sufficient for the development of inspiratory glottal constrictor activity. In conclusion, nNAVA does not induce active inspiratory glottal closure, in contrast to nPSV and nVC. We hypothesize that this absence of inspiratory activity is related to the more physiological airway pressurization during nNAVA, which tightly follows diaphragm electrical activity throughout inspiration.

  13. Study on Mine Emergency Mechanism based on TARP and ICS

    Science.gov (United States)

    Xi, Jian; Wu, Zongzhi

    2018-01-01

    By analyzing the experiences and practices of mine emergency in China and abroad, especially the United States and Australia, normative principle, risk management principle and adaptability principle of constructing mine emergency mechanism based on Trigger Action Response Plans (TARP) and Incident Command System (ICS) are summarized. Classification method, framework, flow and subject of TARP and ICS which are suitable for the actual situation of domestic mine emergency are proposed. The system dynamics model of TARP and ICS is established. The parameters such as evacuation ratio, response rate, per capita emergency capability and entry rate of rescuers are set up. By simulating the operation process of TARP and ICS, the impact of these parameters on the emergency process are analyzed, which could provide a reference and basis for building emergency capacity, formulating emergency plans and setting up action plans in the emergency process.

  14. Effect of immersion on lung capacities and volumes: implications for the densitometric estimation of relative body fat.

    Science.gov (United States)

    Withers, R T; Hamdorf, P A

    1989-01-01

    Immersion of 18 male subjects in water caused a 20.4% (787 ml) increase (P less than 0.05) in the mean inspiratory capacity (IC) whereas there were no changes (P greater than 0.05) in tidal volume (VT) and the frequency of respiration. All the means for the other pulmonary variables decreased (P less than 0.05) by varying amounts: total lung capacity (TLC) = 8.4% (599 ml), vital capacity (VC) = 5.5% (308 ml), functional residual capacity (FRC) = 42.6% (1386 ml), expiratory reserve volume (ERV) = 61.9% (1095 ml) and residual volume (RV) = 19.7% (292 ml). Variation of only the RV in the body density (BD) formula from which the percentage body fat (%BF) is estimated resulted in a significantly (P less than 0.05) lower mean of 15.2% BF for the RV in air (means = 1482 ml) compared with that of 17.1% BF for the RV in water (means = 1190 ml). All but one of the subjects exhibited a smaller RV in water than in air; the six largest differences were equivalent to 2.4-5.1% BF. These results indicate that the net effect of the hydrostatic pressure (decreases RV), pulmonary vascular engorgement (decreases RV) and diminished compliance (increases RV) is to reduce the ventilated RV. It is therefore advisable to measure the RV when the subject is immersed in order to minimize error in the determination of BD and hence the estimation of % BF.

  15. Guiding Inspiratory Flow: Development of the In-Check DIAL G16, a Tool for Improving Inhaler Technique

    Directory of Open Access Journals (Sweden)

    Mark Jeremy Sanders

    2017-01-01

    Full Text Available Portable inhalers are divisible into those that deliver medication by patient triggering (pMDIs: a gentle slow inhalation and those that use the patient’s inspiratory effort as the force for deaggregation and delivery (DPIs: a stronger deeper inspiratory effort. Patient confusion and poor technique are commonplace. The use of training tools has become standard practice, and unique amongst these is an inspiratory flow meter (In-Check which is able to simulate the resistance characteristics of different inhalers and, thereby, guide the patient to the correct effort. In-Check’s origins lie in the 1960s peak expiratory flow meters, the development of the Mini-Wright peak flow meter, and inspiratory flow assessment via the nose during the 1970s–1980s. The current device (In-Check DIAL G16 is the third iteration of the original 1998 training tool, with detailed and ongoing assessments of all common inhaler resistances (including combination and breath-actuated inhaler types summarised into resistance ranges that are preset within the device. The device works by interpolating one of six ranges with the inspiratory effort. Use of the tool has been shown to be contributory to significant improvements in asthma care and control, and it is being advocated for assessment and training in irreversible lung disease.

  16. The Effect of Inspiratory Resistance on Exercise Performance and Perception in Moderate Normobaric Hypoxia.

    Science.gov (United States)

    Seo, Yongsuk; Vaughan, Jeremiah; Quinn, Tyler D; Followay, Brittany; Roberge, Raymond; Glickman, Ellen L; Kim, Jung-Hyun

    2017-12-01

    Seo, Yongsuk, Jeremiah Vaughan, Tyler D. Quinn, Brittany Followay, Raymond Roberge, Ellen L. Glickman, and Jung-Hyun Kim. The effect of inspiratory resistance on exercise performance and perception in moderate normobaric hypoxia. High Alt Med Biol. 18:417-424, 2017. Respirators are simple and efficient in protecting workers against toxic airborne substances; however, their use may limit the physical performance of workers. The purpose of this study was to determine the effect of inspiratory resistance on physical performance and breathing perception in normobaric hypoxia. Nine healthy men wore a tight-fitting respiratory mask outfitted with one of four different inspiratory resistors (R) (0, 1.5, 4.5, 7.5 cm H 2 O/L/Sec) while exercising at normobaric hypoxia (17% O 2 ) at submaximal exercise workloads of 50, 100, and 150 W on a cycle ergometer for 10 minutes each, followed by a maximal oxygen uptake (VO 2 max) test to exhaustion. Maximal power output at R7.5 was significantly lower than R0 (p = 0.016) and R1.5 (p = 0.035). Respiration rate was significantly reduced at R4.5 (p = 0.011) and R7.5 (p ≤ 0.001) compared with R0. Minute ventilation was significantly decreased in R7.5 compared with R0 (p = 0.003), R1.5 (p = 0.010), and R4.5 (p = 0.016), whereas VO 2 was not significantly changed. Breathing comfort (BC) and breathing effort (BE) were significantly impaired in R7.5 (BC: p = 0.025, BE: p = 0.001) and R4.5 (BC: p = 0.007, BE: p = 0.001) compared with R0, but rating of perceived exertion (RPE) remained unchanged. Added inspiratory resistance limited maximal power output and increased perceptions of BC and BE in normobaric hypoxia. However, low-to-moderate inspiratory resistance did not have a deleterious effect on VO 2 or RPE at submaximal or maximal exercise. Perceptual and physiological characteristics of respirators of varying inspiratory resistances should be considered by manufacturers and end users during

  17. A comparison of maximal inspiratory pressure and forced vital capacity as potential criteria for initiating non-invasive ventilation in amyotrophic lateral sclerosis.

    Science.gov (United States)

    Mendoza, Michelle; Gelinas, Deborah F; Moore, Dan H; Miller, Robert G

    2007-04-01

    Using a retrospective analysis of 161 patients with amyotrophic lateral sclerosis (ALS) from the Western ALS study group (WALS) database, the sensitivity of maximal inspiratory pressure (MIP)NIV) were compared. Sixty-five per cent of patients at enrollment met the MIP criterion, compared with only 8% of patients who met the FVC criterion. There were no cases in which FVCNIV, a MIP< -60 cm H(2)O allows US clinicians to obtain non-invasive ventilatory support for patients earlier than if using the FVC criterion alone.

  18. Reprint of "Learning to breathe? Feedforward regulation of the inspiratory motor drive".

    Science.gov (United States)

    Zaman, Jonas; Van den Bergh, Omer; Fannes, Stien; Van Diest, Ilse

    2014-12-01

    Claims have been made that breathing is in part controlled by feedforward regulation. In a classical conditioning paradigm, we investigated anticipatory increases in the inspiratory motor drive as measured by inspiratory occlusion pressure (P100). In an acquisition phase, an experimental group (N = 13) received a low-intensity resistive load (5 cmH2O/l/s) for three consecutive inspirations as Conditioned Stimulus (CS), preceding a load of a stronger intensity (20 cmH2O/l/s) for three subsequent inspirations as unconditioned stimulus (US). The control group (N = 11) received the low-intensity load for six consecutive inspirations. In a post-acquisition phase both groups received the low-intensity load for six consecutive inspirations. Responses to the CS-load only differed between groups during the first acquisition trials and a strong increase in P100 during the US-loads was observed, which habituated across the experiment. Our results suggest that the disruption caused by adding low to moderate resistive loads to three consecutive inspirations results in a short-lasting anticipatory increase in inspiratory motor drive. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Developmental plasticity of phrenic motoneuron and diaphragm properties with the inception of inspiratory drive transmission in utero.

    Science.gov (United States)

    Greer, John J; Martin-Caraballo, Miguel

    2017-01-01

    The review outlines data consistent with the hypothesis that inspiratory drive transmission that generates fetal breathing movements (FBMs) is essential for the developmental plasticity of phrenic motoneurons (PMNs) and diaphragm musculature prior to birth. A systematic examination during the perinatal period demonstrated a very marked transformation of PMN and diaphragm properties coinciding with the onset and strengthening of inspiratory drive and FBMs in utero. This included studies of age-dependent changes of: i) morphology, neuronal coupling, passive and electrophysiological properties of PMNs; ii) rhythmic inspiratory activity in vitro; iii) FBMs generated in vivo detected by ultrasonography; iv) contractile and end-plate potential properties of diaphragm musculature. We also propose how the hypothesis can be further evaluated with studies of perinatal hypoglossal motoneuron-tongue musculature and the use of Dbx1 null mice that provide an experimental model lacking descending inspiratory drive transmission in utero. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Variations in peak nasal inspiratory flow among healthy students after using saline solutions.

    Science.gov (United States)

    Olbrich Neto, Jaime; Olbrich, Sandra Regina Leite Rosa; Mori, Natália Leite Rosa; Oliveira, Ana Elisa de; Corrente, José Eduardo

    2016-01-01

    Nasal hygiene with saline solutions has been shown to relieve congestion, reduce the thickening of the mucus and keep nasal cavity clean and moist. Evaluating whether saline solutions improve nasal inspiratory flow among healthy children. Students between 8 and 11 years of age underwent 6 procedures with saline solutions at different concentrations. The peak nasal inspiratory flow was measured before and 30 min after each procedure. Statistical analysis was performed by means of t test, analysis of variance, and Tukey's test, considering p<0.05. We evaluated 124 children at all stages. There were differences on the way a same concentration was used. There was no difference between 0.9% saline solution and 3% saline solution by using a syringe. The 3% saline solution had higher averages of peak nasal inspiratory flow, but it was not significantly higher than the 0.9% saline solution. It is important to offer various options to patients. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  1. Optimal arrangement of magnetic coils for functional magnetic stimulation of the inspiratory muscles in dogs.

    Science.gov (United States)

    Lin, Vernon Weh-Hau; Zhu, Ercheng; Sasse, Scott A; Sassoon, Catherine; Hsiao, Ian N

    2005-12-01

    In an attempt to maximize inspiratory pressure and volume, the optimal position of a single or of dual magnetic coils during functional magnetic stimulation (FMS) of the inspiratory muscles was evaluated in twenty-three dogs. Unilateral phrenic magnetic stimulation (UPMS) or bilateral phrenic magnetic stimulation (BPMS), posterior cervical magnetic stimulation (PCMS), anterior cervical magnetic stimulation (ACMS) as well as a combination of PCMS and ACMS were performed. Trans-diaphragmatic pressure (Pdi), flow, and lung volume changes with an open airway were measured. Transdiaphragmatic pressure was also measured with an occluded airway. Changes in inspiratory parameters during FMS were compared with 1) electrical stimulation of surgically exposed bilateral phrenic nerves (BPES) and 2) ventral root electrical stimulation at C5-C7 (VRES C5-C7). Relative to the Pdi generated by BPES of 36.3 +/- 4.5 cm H2O (Mean +/- SEM), occluded Pdi(s) produced by UPMS, BPMS, PCMS, ACMS, and a combined PCMS + ACMS were 51.7%, 61.5%, 22.4%, 100.3%, and 104.5% of the maximal Pdi, respectively. Pdi(s) produced by UPMS, BPMS, PCMS, ACMS, and combined ACMS + PCMS were 38.0%, 45.2%, 16.5%, 73.8%, and 76.8%, respectively, of the Pdi induced by VRES (C5-C7) (48.0 +/- 3.9 cm H2O). The maximal Pdi(s) generated during ACMS and combined PCMS + ACMS were higher than the maximal Pdi(s) generated during UPMS, BPMS, or PCMS (p BPMS or PCMS. ACMS can be used to generate sufficient inspiratory pressure, flow, and volume for activation of the inspiratory muscles.

  2. Inspiratory muscle training in pediatrics: main indications and technical characteristics of the protocols

    Directory of Open Access Journals (Sweden)

    Cristhiele Tais Woszezenki

    Full Text Available Abstract Introduction: Inspiratory muscle training (IMT is a resource widely used in pediatrics. However, there is great variability in relation to the characteristics of the protocols used. Objective: To identify the main clinical conditions and IMT protocols used in the pediatric age group. Methods: Integrative review of the literature by searching on Pubmed, Scielo, PEDro and EMBASE databases using the following strategy: threshold OR inspiratory muscle training OR muscle endurance OR muscle resistance OR endurance training OR maximal inspiratory pressure AND respiratory muscle. We have selected clinical trials that performed IMT in children and adolescents (0 to 18 years old, with a clinical diagnosis, and published in English, Portuguese and Spanish. Results: 17 studies were included. From these, 11 underwent IMT in patients with some neuromuscular disorder, being Duchenne Muscular Dystrophy the most common. The selected articles included a total sample of 327 participants. As for the characteristics of the protocols, 7 performed strength training, 5 endurance and 5 strength and endurance. The training load ranged from 30 to 80% of maximal inspiratory pressure. Moreover, 8 studies performed IMT twice daily and the session duration and the training period varied between 10 and 30 minutes, and from 3 weeks to 24 months, respectively. Conclusion: The IMT was used more frequently in patients with some neuromuscular disorder. Although there is no consensus as to the characteristics of the protocols, the choice of the load should take into account the purpose of IMT and the disease severity.

  3. Benefits of combining inspiratory muscle with 'whole muscle' training in children with cystic fibrosis: a randomised controlled trial

    NARCIS (Netherlands)

    Santana-Sosa, Elena; Gonzalez-Saiz, Laura; Groeneveld, Iris F.; Villa-Asensi, José R.; Barrio Gómez de Aguero, María I.; Fleck, Steven J.; López-Mojares, Luis M.; Pérez, Margarita; Lucia, Alejandro

    2014-01-01

    The purpose of this study (randomised controlled trial) was to assess the effects of an 8-week combined 'whole muscle' (resistance+aerobic) and inspiratory muscle training (IMT) on lung volume, inspiratory muscle strength (PImax) and cardiorespiratory fitness (VO2 peak) (primary outcomes), and

  4. Thyrotropin-releasing hormone (TRH) depolarizes a subset of inspiratory neurons in the newborn mouse brain stem in vitro

    DEFF Research Database (Denmark)

    Rekling, J C; Champagnat, J; Denavit-Saubié, M

    1996-01-01

    neurons located in the rostral ventrolateral part of the slice. 2. Bath-applied TRH (1 microM) decreased the time between inspiratory discharges recorded on the XII nerve from 12.3 +/- 3.3 s to 4.9 +/- 1.1 s (n = 28; means +/- SD), i.e., caused an approximate threefold increase in the respiratory...... frequency. The coefficient of variation of the time between the inspiratory discharges decreased by one-half. Thus the respiratory output became more stable in response to TRH. The duration of the inspiratory discharges increased from 474 +/- 108 ms to 679 +/- 114 ms, and the amplitude decreased by 24...... in a thick brain stem slice preparation from the newborn mouse. The action of TRH on the respiratory output from the slice was investigated by recordings from the XII nerve. Cellular responses to TRH were investigated using whole cell recordings from hypoglossal motoneurons and three types of inspiratory...

  5. Normal values for inspiratory muscle function in children

    International Nuclear Information System (INIS)

    Mellies, Uwe; Stehling, Florian; Dohna-Schwake, Christian

    2014-01-01

    Assessment of inspiratory muscle function (IMF) is limited in children with neuromuscular disorders, because respiratory muscle tests are poorly standardized and valid normative data are unavailable. We investigated maximum inspiratory pressure after exhalation to residual volume (MIP), mouth occlusion pressure (P0.1) and time of inspiration during quiet breathing and derived inspiratory muscle load (P0.1/MIP), and tension time index (TTI) in 301 healthy schoolchildren 6–16 years old. Gender-specific and age-dependent percentile curves for MIP were drawn with the median, 5%, 10%, 25%, 75% and 95% percentile. P0.1 was equal in boys and girls (0.23  ±  0.11 kPa), while MIP was significantly higher in boys (6.8  ±  2.2 versus 5.8  ±  2.4 kPa). Consequently, P0.1/MIP (4.8% ± 3.2% versus 4.0% ± 3.1%) and TTI (0.2  ±  0.14 versus 0.16  ±  0.14) were significantly higher in girls. MIP was 2.90 + 0.36 × age (kPa) and 3.19 + 0.24 × age (kPa) in boys and girls, respectively. The 95% confidence intervals for boys and girls, respectively, were MIP, 6.3–7.3 kPA and 5.4–6.2 kPa; P0.1/MIP, 3.5%–4.5% and 4.3%–5.3%; TTI, 0.14–0.18 and 0.18–0.22; and P0.1, 0.20–0.24 kPa for both. IMF in children has a wide interindividual variability; however percentile curves facilitate a longitudinal assessment of individual patients. Furthermore, narrow confidence intervals allow for comparisons of study populations, making IMF an appropriate endpoint for clinical trials. (paper)

  6. Diagnosis of tracheal instability: inspiratory and expiratory spiral CT and cine CT

    International Nuclear Information System (INIS)

    Heussel, C.P.; Thelen, M.; Kauczor, H.U.; Hafner, B.; Lill, J.

    2000-01-01

    Purpose: In tracheo- and bronchomalacia, localization and determination of collapse is necessary for planning a surgical procedure. We compared inspiratory and spiral CT, cine CT, and bronchoscopy and evaluated the relevance of each method. Methods: Seventeen patients with suspected or verified tracheal stonosis or collapse underwent paired inspiratory and exspiratory spiral CT and cine CT during continuous respiration (temporal increment 100 ms). The tracheal cross-sectional area was calculated and compared. Results: In addition to bronchoscopy, further information concerning localization, extent, collapse, stability of the tracheal wall, distal portions of the stenosis, and extraluminal compressions was obtained. A significantly higher degree of tracheal collapse was seen using cine CT compared to paired spiral CT (p [de

  7. Effect of hyperinflation on inspiratory function of the diaphragm.

    Science.gov (United States)

    Minh, V D; Dolan, G F; Konopka, R F; Moser, K M

    1976-01-01

    The inspiratory efficiency of the diaphragm during unilateral and bilateral phrenic stimulation (UEPS and BEPS) with constant stimulus was studied in seven dogs from FRC to 120% TLC. Alveolar pressures (PAl) were recorded during relaxation, BEPS and UEPS at each lung volume in the closed respiratory system. From the PAl-lung volume curves, tidal volume (VT), and pressure developed by the diaphragm (Pmus) were derived. Results are summarized below. a) Hyperinflation impaired the inspiratory efficiency of the diaphragm which behaved as an expiratory muscle beyond the lung volume of 103.7% TLC (Vinef). b) The diaphragm during UEPS became expiratory at the same Vinef as during (BEPS. C) The VT-lung volume relationship was linear during BEPS, allowing simple quantitation of VT loss with hyperinflation and prediction of Vinef. d) With only one phrenic nerve stimulated, the functional loss is less pronounced in VT than in Pmus, as compared to BEPS, indicating that the respiratory system was more compliant during UEPS than BEPS. This compliance difference from UEPS to BEPS diminished with severe hyperinflation.

  8. Reduced phrenic motoneuron recruitment during sustained inspiratory threshold loading compared to single-breath loading: a twitch interpolation study

    Directory of Open Access Journals (Sweden)

    Mathieu Raux

    2016-11-01

    Full Text Available In humans, inspiratory constraints engage cortical networks involving the supplementary motor area. Functional magnetic resonance imaging (fMRI shows that the spread and intensity of the corresponding respiratory-related cortical activation dramatically decrease when a discrete load becomes sustained. This has been interpreted as reflecting motor cortical reorganisation and automatisation, but could proceed from sensory and/or affective habituation. To corroborate the existence of motor reorganisation between single-breath and sustained inspiratory loading (namely changes in motor neurones recruitment, we conducted a diaphragm twitch interpolation study based on the hypothesis that motor reorganisation should result in changes in the twitch interpolation slope. Fourteen healthy subjects (age: 21 – 40 years were studied. Bilateral phrenic stimulation was delivered at rest, upon prepared and targeted voluntary inspiratory efforts (vol, upon unprepared inspiratory efforts against a single-breath inspiratory threshold load (single-breath, and upon sustained inspiratory efforts against the same type of load (continuous. The slope of the relationship between diaphragm twitch transdiaphragmatic pressure and the underlying transdiaphragmatic pressure was –1.1 ± 0.2 during vol, –1.5 ± 0.7 during single-breath, and -0.6 ± 0.4 during continuous (all slopes expressed in percent of baseline.percent of baseline-1 all comparisons significant at the 5% level. The contribution of the diaphragm to inspiration, as assessed by the gastric pressure to transdiaphragmatic pressure ratio, was 31 ± 17 % during vol, 22 ± 16 % during single-breath (p=0.13, and 19 ± 9 % during continuous (p = 0.0015 vs. vol. This study shows that the relationship between the amplitude of the transdiaphragmatic pressure produced by a diaphragm twitch and its counterpart produced by the underlying diaphragm contraction is not unequivocal. If twitch interpolation is interpreted as

  9. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD.

    Science.gov (United States)

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A; Campos, Michael A; Cahalin, Lawrence P

    2018-01-01

    The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Test-retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test-retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. The TIRE measures of MIP, SMIP and ID have excellent test-retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP.

  10. Some infant ventilators do not limit peak inspiratory pressure reliably during active expiration.

    Science.gov (United States)

    Kirpalani, H; Santos-Lyn, R; Roberts, R

    1988-09-01

    In order to minimize barotrauma in newborn infants with respiratory failure, peak inspiratory pressures should not exceed those required for adequate gas exchange. We examined whether four commonly used pressure-limited, constant flow ventilators limit pressure reliably during simulated active expiration against the inspiratory stroke of the ventilator. Three machines of each type were tested at 13 different expiratory flow rates (2 to 14 L/min). Flow-dependent pressure overshoot above a dialed pressure limit of 20 cm H2O was observed in all machines. However, the magnitude differed significantly between ventilators from different manufacturers (p = .0009). Pressure overshoot above 20 cm H2O was consistently lowest in the Healthdyne (0.8 cm H2O at 2 L/min, 3.6 cm H2O at 14 L/min) and highest in the Bourns BP200 (3.0 cm H2O at 2 L/min, 15.4 cm H2O at 14 L/min). We conclude that peak inspiratory pressure overshoots on pressure-limited ventilators occur during asynchronous expiration. This shortcoming may contribute to barotrauma in newborn infants who "fight" positive-pressure ventilation.

  11. Inspiratory stridor and dysphagia because of prolonged oesophageal foreign body

    NARCIS (Netherlands)

    Vos, G. D.; Heymans, H. S.; Urbanus, N. A.

    1987-01-01

    A 2-year-old boy with severe inspiratory stridor and dysphagia is described. The delay in the diagnosis of an impacted foreign body resulted in severe deformation of the oesophagus. After surgical extraction of the foreign body the oesophagus was splinted for 4 months by a nasogastric tube because

  12. Mod 1 ICS TI Report: ICS Conversion of a 140% HPGe Detector

    Energy Technology Data Exchange (ETDEWEB)

    Bounds, John Alan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-07-05

    This report evaluates the Mod 1 ICS, an electrically cooled 140% HPGe detector. It is a custom version of the ORTEC Integrated Cooling System (ICS) modified to make it more practical for us to use in the field. Performance and operating characteristics of the Mod 1 ICS are documented, noting both pros and cons. The Mod 1 ICS is deemed a success. Recommendations for a Mod 2 ICS, a true field prototype, are provided.

  13. Cystic lung disease: a comparison of cystic size, as seen on expiratory and inspiratory HRCT scans

    International Nuclear Information System (INIS)

    Lee, Ki Nam; Yoon, Seong Kuk; Nam, Kyung Jin; Choi, Seok Jin; Goo, Jin Mo

    2000-01-01

    To determine the effects of respiration on the size of lung cysts by comparing inspiratory and expiratory high-resolution CT (HRCT) scans. The authors evaluated the size of cystic lesions, as seen on paired inspiratory and expiratory HRCT scans, in 54 patients with Langerhans cell histiocytosis (n = 3), pulmonary lymphangiomyomatosis (n = 4), confluent centrilobular emphysema (n = 9), paraseptal emphysema and bullae (n = 16), cystic bronchiectasis (n = 13), and honeycombing (n = 9). Using paired inspiratory and expiratory HRCT scans obtained at the corresponding anatomic level, a total of 270 cystic lesions were selected simultaneously on the basis of five lesions per lung disease. Changes in lung cyst size observed during respiration were assessed by two radiologists. In a limited number of cases (n = 11), pathologic specimens were obtained by open lung biopsy or lobectomy. All cystic lesions in patients with Langerhans cell histiocytosis, lymphangiomyomatosis, cystic bronchiectasis, honeycombing, and confluent centrilobular emphysema became smaller on expiration, but in two cases of paraseptal emphysema and bullae there was no change. In cases in which expiratory CT scans indicate that cysts have become smaller, cystic lesions may communicate with the airways. To determine whether, for cysts and cystic lesions, this connection does in fact exist, paired inspiratory and expiratory HRCT scans are necessary

  14. Cystic lung disease: a comparison of cystic size, as seen on expiratory and inspiratory HRCT scans

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ki Nam; Yoon, Seong Kuk; Nam, Kyung Jin [Donga University College of Medicine, Pusan (Korea, Republic of); Choi, Seok Jin [Inje University College of Medicine, Gimhae (Korea, Republic of); Goo, Jin Mo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2000-06-01

    To determine the effects of respiration on the size of lung cysts by comparing inspiratory and expiratory high-resolution CT (HRCT) scans. The authors evaluated the size of cystic lesions, as seen on paired inspiratory and expiratory HRCT scans, in 54 patients with Langerhans cell histiocytosis (n = 3), pulmonary lymphangiomyomatosis (n = 4), confluent centrilobular emphysema (n = 9), paraseptal emphysema and bullae (n = 16), cystic bronchiectasis (n = 13), and honeycombing (n = 9). Using paired inspiratory and expiratory HRCT scans obtained at the corresponding anatomic level, a total of 270 cystic lesions were selected simultaneously on the basis of five lesions per lung disease. Changes in lung cyst size observed during respiration were assessed by two radiologists. In a limited number of cases (n = 11), pathologic specimens were obtained by open lung biopsy or lobectomy. All cystic lesions in patients with Langerhans cell histiocytosis, lymphangiomyomatosis, cystic bronchiectasis, honeycombing, and confluent centrilobular emphysema became smaller on expiration, but in two cases of paraseptal emphysema and bullae there was no change. In cases in which expiratory CT scans indicate that cysts have become smaller, cystic lesions may communicate with the airways. To determine whether, for cysts and cystic lesions, this connection does in fact exist, paired inspiratory and expiratory HRCT scans are necessary.

  15. Extubation process in bed-ridden elderly intensive care patients receiving inspiratory muscle training: a randomized clinical trial.

    Science.gov (United States)

    Cader, Samária Ali; de Souza Vale, Rodrigo Gomes; Zamora, Victor Emmanuel; Costa, Claudia Henrique; Dantas, Estélio Henrique Martin

    2012-01-01

    The purpose of this study was to evaluate the extubation process in bed-ridden elderly intensive care patients receiving inspiratory muscle training (IMT) and identify predictors of successful weaning. Twenty-eight elderly intubated patients in an intensive care unit were randomly assigned to an experimental group (n = 14) that received conventional physiotherapy plus IMT with a Threshold IMT(®) device or to a control group (n = 14) that received only conventional physiotherapy. The experimental protocol for muscle training consisted of an initial load of 30% maximum inspiratory pressure, which was increased by 10% daily. The training was administered for 5 minutes, twice daily, 7 days a week, with supplemental oxygen from the beginning of weaning until extubation. Successful extubation was defined by the ventilation time measurement with noninvasive positive pressure. A vacuum manometer was used for measurement of maximum inspiratory pressure, and the patients' Tobin index values were measured using a ventilometer. The maximum inspiratory pressure increased significantly (by 7 cm H(2)O, 95% confidence interval [CI] 4-10), and the Tobin index decreased significantly (by 16 breaths/ min/L, 95% CI -26 to 6) in the experimental group compared with the control group. The Chi-squared distribution did not indicate a significant difference in weaning success between the groups (χ(2) = 1.47; P = 0.20). However, a comparison of noninvasive positive pressure time dependence indicated a significantly lower value for the experimental group (P = 0.0001; 95% CI 13.08-18.06). The receiver-operating characteristic curve showed an area beneath the curve of 0.877 ± 0.06 for the Tobin index and 0.845 ± 0.07 for maximum inspiratory pressure. The IMT intervention significantly increased maximum inspiratory pressure and significantly reduced the Tobin index; both measures are considered to be good extubation indices. IMT was associated with a reduction in noninvasive positive

  16. Extubation process in bed-ridden elderly intensive care patients receiving inspiratory muscle training: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Cader SA

    2012-10-01

    Full Text Available Samária Ali Cader,1 Rodrigo Gomes de Souza Vale,1 Victor Emmanuel Zamora,2 Claudia Henrique Costa,2 Estélio Henrique Martin Dantas11Laboratory of Human Kinetics Bioscience, Federal University of Rio de Janeiro State, 2Pedro Ernesto University Hospital, School of Medicine, State University of Rio de Janeiro, Rio de Janeiro, BrazilBackground: The purpose of this study was to evaluate the extubation process in bed-ridden elderly intensive care patients receiving inspiratory muscle training (IMT and identify predictors of successful weaning.Methods: Twenty-eight elderly intubated patients in an intensive care unit were randomly assigned to an experimental group (n = 14 that received conventional physiotherapy plus IMT with a Threshold IMT® device or to a control group (n = 14 that received only conventional physiotherapy. The experimental protocol for muscle training consisted of an initial load of 30% maximum inspiratory pressure, which was increased by 10% daily. The training was administered for 5 minutes, twice daily, 7 days a week, with supplemental oxygen from the beginning of weaning until extubation. Successful extubation was defined by the ventilation time measurement with noninvasive positive pressure. A vacuum manometer was used for measurement of maximum inspiratory pressure, and the patients' Tobin index values were measured using a ventilometer.Results: The maximum inspiratory pressure increased significantly (by 7 cm H2O, 95% confidence interval [CI] 4–10, and the Tobin index decreased significantly (by 16 breaths/min/L, 95% CI −26 to 6 in the experimental group compared with the control group. The Chi-squared distribution did not indicate a significant difference in weaning success between the groups (Χ2 = 1.47; P = 0.20. However, a comparison of noninvasive positive pressure time dependence indicated a significantly lower value for the experimental group (P = 0.0001; 95% CI 13.08–18.06. The receiver

  17. Heat and moisture exchange capacity of the upper respiratory tract and the effect of tracheotomy breathing on endotracheal climate.

    Science.gov (United States)

    Scheenstra, Renske J; Muller, Sara H; Vincent, Andrew; Hilgers, Frans J M

    2011-01-01

    The aim of this study was to assess the heat and moisture exchange (HME) capacity of the upper respiratory tract and the effect of tracheotomy breathing on endotracheal climate in patients with head and neck cancer. We plotted the subglottic temperature and humidity measurements in 10 patients with head and neck cancer with a temporary precautionary tracheotomy during successive 10-minute periods of nose, mouth, and tracheotomy breathing in a randomized sequence. End-inspiratory temperatures of nose, mouth, and tracheotomy breathing were 31.1, 31.3, and 28.3°C, respectively. End-inspiratory humidity measurements of nose, mouth, and tracheotomy breathing were 29.3, 28.6, and 21.1 mgH₂O/L, respectively. There was a trend toward lower end-inspiratory humidity in patients with radiotherapy or with large surgery-induced oropharyngeal mucosal defects, whereas temperatures were similar. This study gives objective information about the HME capacity of the upper respiratory tract in patients with head and neck cancer with precautionary tracheotomy, and thus provides target values for HMEs for laryngectomized and tracheotomized patients. © 2010 Wiley Periodicals, Inc. Head Neck, 2011.

  18. Electroresponsive properties and membrane potential trajectories of three types of inspiratory neurons in the newborn mouse brain stem in vitro

    DEFF Research Database (Denmark)

    Rekling, J C; Champagnat, J; Denavit-Saubié, M

    1996-01-01

    with the aim of extending the classification of inspiratory neurons to include analysis of active membrane properties. 2. The slice generated a regular rhythmic motor output recorded as burst of action potentials on a XII nerve root with a peak to peak time of 11.5 +/- 3.4 s and a duration of 483 +/- 54 ms......1. The electrophysiological properties of inspiratory neurons were studied in a rhythmically active thick-slice preparation of the newborn mouse brain stem maintained in vitro. Whole cell patch recordings were performed from 60 inspiratory neurons within the rostral ventrolateral part of the slice...

  19. Neopuff T-piece resuscitator mask ventilation: Does mask leak vary with different peak inspiratory pressures in a manikin model?

    Science.gov (United States)

    Maheshwari, Rajesh; Tracy, Mark; Hinder, Murray; Wright, Audrey

    2017-08-01

    The aim of this study was to compare mask leak with three different peak inspiratory pressure (PIP) settings during T-piece resuscitator (TPR; Neopuff) mask ventilation on a neonatal manikin model. Participants were neonatal unit staff members. They were instructed to provide mask ventilation with a TPR with three PIP settings (20, 30, 40 cm H 2 O) chosen in a random order. Each episode was for 2 min with 2-min rest period. Flow rate and positive end-expiratory pressure (PEEP) were kept constant. Airway pressure, inspiratory and expiratory tidal volumes, mask leak, respiratory rate and inspiratory time were recorded. Repeated measures analysis of variance was used for statistical analysis. A total of 12 749 inflations delivered by 40 participants were analysed. There were no statistically significant differences (P > 0.05) in the mask leak with the three PIP settings. No statistically significant differences were seen in respiratory rate and inspiratory time with the three PIP settings. There was a significant rise in PEEP as the PIP increased. Failure to achieve the desired PIP was observed especially at the higher settings. In a neonatal manikin model, the mask leak does not vary as a function of the PIP when the flow rate is constant. With a fixed rate and inspiratory time, there seems to be a rise in PEEP with increasing PIP. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  20. Excitatory Modulation of the preBötzinger Complex Inspiratory Rhythm Generating Network by Endogenous Hydrogen Sulfide

    Directory of Open Access Journals (Sweden)

    Glauber S. F. da Silva

    2017-06-01

    Full Text Available Hydrogen Sulfide (H2S is one of three gasotransmitters that modulate excitability in the CNS. Global application of H2S donors or inhibitors of H2S synthesis to the respiratory network has suggested that inspiratory rhythm is modulated by exogenous and endogenous H2S. However, effects have been variable, which may reflect that the RTN/pFRG (retrotrapezoid nucleus, parafacial respiratory group and the preBötzinger Complex (preBötC, critical for inspiratory rhythm generation are differentially modulated by exogenous H2S. Importantly, site-specific modulation of respiratory nuclei by H2S means that targeted, rather than global, manipulation of respiratory nuclei is required to understand the role of H2S signaling in respiratory control. Thus, our aim was to test whether endogenous H2S, which is produced by cystathionine-β-synthase (CBS in the CNS, acts specifically within the preBötC to modulate inspiratory activity under basal (in vitro/in vivo and hypoxic conditions (in vivo. Inhibition of endogenous H2S production by bath application of the CBS inhibitor, aminooxyacetic acid (AOAA, 0.1–1.0 mM to rhythmic brainstem spinal cord (BSSC and medullary slice preparations from newborn rats, or local application of AOAA into the preBötC (slices only caused a dose-dependent decrease in burst frequency. Unilateral injection of AOAA into the preBötC of anesthetized, paralyzed adult rats decreased basal inspiratory burst frequency, amplitude and ventilatory output. AOAA in vivo did not affect the initial hypoxia-induced (10% O2, 5 min increase in ventilatory output, but enhanced the secondary hypoxic respiratory depression. These data suggest that the preBötC inspiratory network receives tonic excitatory modulation from the CBS-H2S system, and that endogenous H2S attenuates the secondary hypoxic respiratory depression.

  1. Children and IC

    Science.gov (United States)

    ... Cola, and Orange Crush, for example), Kool-Aid, chocolate, and many fruits, fruit juices and drinks (including ... Guideline IC Treatments IC Diet & Self Management Physical Therapy Antidepressants Antihistamines Pentosan Polysulfate Sodium Bladder Instillations Immunosuppresants ...

  2. Men and IC

    Science.gov (United States)

    ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ...

  3. General IC Symptoms

    Science.gov (United States)

    ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ...

  4. Pregnancy and IC

    Science.gov (United States)

    ... have not already done so, try to identify foods, beverages, and supplements that are irritating to your bladder ... Other Medicines Over-the-counter Medicines Pain Management Management of IC ... Diet Food Diaries Least and Most Bothersome Foods IC-Friendly ...

  5. Effect of an external resistance to airflow on the inspiratory flow curve

    NARCIS (Netherlands)

    de Koning, J P; van der Mark, Th W; Coenegracht, P M J; Tromp, Th F J; Frijlink, H W

    2002-01-01

    Inhalation is a convenient way to deliver drugs to the respiratory tract in the treatment of respiratory diseases. For dry powder inhalers (DPI's), the principle of operation is to use the patient-generated inspiratory flow as energy source for emptying of the dose system and the delivery of fine

  6. Slow loaded breathing training improves blood pressure, lung capacity and arm exercise endurance for older people with treated and stable isolated systolic hypertension.

    Science.gov (United States)

    Ublosakka-Jones, Chulee; Tongdee, Phailin; Pachirat, Orathai; Jones, David A

    2018-03-28

    Hypertension and reduced lung function are important features of aging. Slow loaded breathing training reduces resting blood pressure and the question is whether this can also improve lung function. Thirty-two people (67 ± 5 years, 16 male) with controlled isolated systolic hypertension undertook an eight weeks randomised controlled training trial with an inspiratory load of 25% maximum inspiratory pressure (MIP) at 6 breaths per minute (slow loaded breathing; SLB) or deep breathing control (CON). Outcome measures were resting blood pressure (BP) and heart rate; MIP; lung capacity; chest and abdominal expansion; arm cranking exercise endurance at 50% heart rate reserve. Home based measurement of resting systolic BP decreased by 20 mm Hg (15 to 25) (Mean and 95%CI) for SLB and by 5 mm Hg (1 to 7) for CON. Heart rate and diastolic BP also decreased significantly for SLB but not CON. MIP increased by 15.8 cm H 2 O (11.8 to 19.8) and slow vital capacity by 0.21 L (0.15 to 0.27) for SLB but not for CON. Chest and abdominal expansion increased by 2.3 cm (2.05 to 2.55) and 2.5 cm (2.15 to 2.85), respectively for SLB and by 0.5 cm (0.26 to 0.74) and 1.7 cm (1.32 to 2.08) for CON. Arm exercise time increased by 4.9 min (3.65 to 5.15) for SLB with no significant change for CON. Slow inspiratory muscle training is not only effective in reducing resting BP, even in older people with well controlled isolated systolic hypertension but also increases inspiratory muscle strength, lung capacity and arm exercise duration. Copyright © 2018. Published by Elsevier Inc.

  7. Impact of LABA/LAMA combination on exercise endurance and lung hyperinflation in COPD: A pair-wise and network meta-analysis.

    Science.gov (United States)

    Calzetta, Luigino; Ora, Josuel; Cavalli, Francesco; Rogliani, Paola; O'Donnell, Denis E; Cazzola, Mario

    2017-08-01

    The ability to exercise is an important clinical outcome in COPD, and the improvement in exercise capacity is recognized to be an important goal in the management of COPD. Therefore, since the current interest in the use of bronchodilators in COPD is gradually shifting towards the dual bronchodilation, we carried out a meta-analysis to evaluate the impact of LABA/LAMA combination on exercise capacity and lung hyperinflation in COPD. RCTs were identified after a search in different databases of published and unpublished trials. The aim of this study was to assess the influence of LABA/LAMA combinations on endurance time (ET) and inspiratory capacity (IC), vs. monocomponents. Eight RCTs including 1632 COPD patients were meta-analysed. LABA/LAMA combinations were significantly (P meta-analysis. This meta-analysis clearly demonstrates that if the goal of the therapy is to enhance exercise capacity in patients with COPD, LABA/LAMA combinations consistently meet the putative clinically meaningful differences for both ET and IC and, in this respect, are superior to their monocomponents. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. DIFFERENT TYPES OF INSPIRATORY MUSCLE TRAINING PROVIDES BETTERMENT IN ALTERED PULMONARY FUNCTIONS IN UPPER THORACIC SPINAL CORD INJURIES

    Directory of Open Access Journals (Sweden)

    Muruganandam Periyasamy

    2016-08-01

    Full Text Available Background: Respiratory problems are usual in upper thoracic spinal cord injuries when compared to Lower thoracic spinal cord injuries. Generally there are frequent respiratory complications in the individuals with spinal cord injuries. The complications of the respiratory system are severe and more prevalent source of morbidity and mortality after the spinal cord injury due to the inefficient breathing capacity including inspiratory and expiratory abilities. The present study represents the inspiratory muscle training especially in upper thoracic spinal cord injury patients to assess the improvement in the pulmonary functions. Methods: Twenty five patients with the age between 25 -40 years with the upper spinal cord injuries were selected in the present study in order to assess the efficacy of the training. Several types of exercises were practiced including diaphragmatic breathing exercises, incentive spirometry, active cycle of breathing technique and weight training. COPD Conditions, Chest wall deformities, Hypertensive patients, Cardio vascular problems were excluded in the study. Results: The results from the study showed that significant changes were found in the patients treated with all the above mentioned techniques. Axillary level, nipple level, Xiphisternum levels were analysed and the results found to be significant after the treatment. Incentive spirometry and peak flow meter observations were also found to be significant when compare to the pretreatment. Conclusion: The present study conclude that the combined effect of incentive spriometry, diaphragmatic breathing exercises, and active cycle of breathing technique is more effective in improving the pulmonary functions in upper thoracic spinal cord injuries than single method efficiency.

  9. Are glucose levels, glucose variability and autonomic control influenced by inspiratory muscle exercise in patients with type 2 diabetes? Study protocol for a randomized controlled trial.

    Science.gov (United States)

    Schein, Aso; Correa, Aps; Casali, Karina Rabello; Schaan, Beatriz D

    2016-01-20

    Physical exercise reduces glucose levels and glucose variability in patients with type 2 diabetes. Acute inspiratory muscle exercise has been shown to reduce these parameters in a small group of patients with type 2 diabetes, but these results have yet to be confirmed in a well-designed study. The aim of this study is to investigate the effect of acute inspiratory muscle exercise on glucose levels, glucose variability, and cardiovascular autonomic function in patients with type 2 diabetes. This study will use a randomized clinical trial crossover design. A total of 14 subjects will be recruited and randomly allocated to two groups to perform acute inspiratory muscle loading at 2 % of maximal inspiratory pressure (PImax, placebo load) or 60 % of PImax (experimental load). Inspiratory muscle training could be a novel exercise modality to be used to decrease glucose levels and glucose variability. ClinicalTrials.gov NCT02292810 .

  10. Effect of acute inspiratory muscle exercise on blood flow of resting and exercising limbs and glucose levels in type 2 diabetes.

    Science.gov (United States)

    Corrêa, Ana Paula dos Santos; Antunes, Cristiano Fetter; Figueira, Franciele Ramos; de Castro, Marina Axmann; Ribeiro, Jorge Pinto; Schaan, Beatriz D'Agord

    2015-01-01

    To evaluate the effects of inspiratory loading on blood flow of resting and exercising limbs in patients with diabetic autonomic neuropathy. Ten diabetic patients without cardiovascular autonomic neuropathy (DM), 10 patients with cardiovascular autonomic neuropathy (DM-CAN) and 10 healthy controls (C) were randomly assigned to inspiratory muscle load of 60% or 2% of maximal inspiratory pressure (PImax) for approximately 5 min, while resting calf blood flow (CBF) and exercising forearm blood flow (FBF) were measured. Reactive hyperemia was also evaluated. From the 20 diabetic patients initially allocated, 6 wore a continuous glucose monitoring system to evaluate the glucose levels during these two sessions (2%, placebo or 60%, inspiratory muscle metaboreflex). Mean age was 58 ± 8 years, and mean HbA1c, 7.8% (62 mmol/mol) (DM and DM-CAN). A PImax of 60% caused reduction of CBF in DM-CAN and DM (Pexercise was blunted during 60% of PImax in DM-CAN and DM, and augmented in C (Pexercise that recruits the diaphragm can abruptly reduce glucose levels.

  11. Effect of pilates method on inspiratory and expiratory muscle strength in the elderly

    Directory of Open Access Journals (Sweden)

    Beatriz Mendes Tozim

    2018-03-01

    Full Text Available With aging, the respiratory muscle strength decreases and the pilates method is a technique that uses respiration as one of its principles. The present study has the aim of analyzing the influence of the pilates method on respiratory muscle strength in older women. For the evaluation of respiratory muscle strength (inspiratory and expiratory, manovacuometer was used. Thirty-one older women were divided into two groups: 14 participated in the pilates group and 17 in the control group. Participants of the pilates group performed 16 sessions of pilates method with an hour of training, twice week for eight weeks. The control group participated in four educational lectures for eight weeks. For statistical analysis, Shapiro-Wilk, ANOVA for repeated measures (p <0.05 and Cohen’s D index were performed. The results showed significant difference and the mean effect for the Cohen’s D index expiratory muscle strength of the pilates group when comparing before (69.71 ± 25.48 and after (85.23 ± 22.21 training (p<0.05 with an increase of 23%. The results of inspiratory muscle strength were not significant but presented an average effect for the Cohen’s D index for the pilates group before (69.71 ± 35.46 and after (88.00 ± 34.87 training, with an increase of 27%. The control group did not present significant differences for the variables evaluated. It could be concluded that the pilates method is effective in improving expiratory muscle strength and provides positive effects on the increase in inspiratory muscle strength.

  12. Alexithymia and anesthetic bladder capacity in interstitial cystitis/bladder pain syndrome.

    Science.gov (United States)

    Chiu, Chui-De; Lee, Ming-Huei; Chen, Wei-Chih; Ho, Hoi Lam; Wu, Huei-Ching

    2017-09-01

    In contrast to the inconsistent results of organic causes, it has been found that psychological risk factors are reliably related to functional somatic syndromes (FSSs), including interstitial cystitis/bladder pain syndrome (IC/BPS). Compared to patients with acute cystitis, a subgroup of IC/BPS patients with a history of childhood relational trauma reported intensified unregulated affective states (i.e., anxiety and depression) and trauma-related psychopathology (i.e., dissociation). Nevertheless, it remains unknown whether psychosocial risk factors can be separated from bladder-centric factors. This study aimed to verify whether psychosocial factors such as alexithymia, which is a key psychological factor of FSSs, are less likely to be linked to a low bladder capacity in patients with IC/BPS. Ninety-four female IC/BPS patients were recruited from the outpatient departments of urology, obstetrics, and gynecology. Anxiety, depression, dissociation, childhood relational trauma, and alexithymia were assessed using standardized scales, and anesthetic bladder capacity was examined by cystoscopic hydrodistention. Positive correlations were found between anesthetic bladder capacity and the psychosocial variables, including alexithymia. An increased bladder capacity was associated with anxiety, dissociation, and childhood relational trauma, and a combination of high cognitive and low affective alexithymia mediated the correlations between bladder capacity and the psychosocial variables. Psychosocial variables that are associated with an aversive childhood relational environment and affect dysregulation may constitute a pathogenic trajectory that differs from bladder-centric defects such as a lower bladder capacity. The findings of this study support the notion that IC/BPS in some patients may be due to an FSS. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Abundances of Planetary Nebulae IC 418, IC 2165 and NGC 5882

    NARCIS (Netherlands)

    Pottasch, [No Value; Bernard-Salas, J; Beintema, DA; Feibelman, WA

    The ISO and IUE spectra of the elliptical nebulae NGC 5882, IC 418 and IC 2165 are presented. These spectra are combined with the spectra in the visual wavelength region to obtain a complete, extinction corrected, spectrum. The chemical composition of the nebulae is then calculated and compared to

  14. The effect of entrainment site and inspiratory pressure on the delivery of oxygen therapy during non-invasive mechanical ventilation (NIMV in acute COPD patients

    Directory of Open Access Journals (Sweden)

    Sundeep Kaul

    2006-12-01

    Full Text Available Supplemental O2 is frequently added to bi-level non-invasive ventilation circuits to maintain Sa,O2 >90%. Oxygen can be added at several points & in the presence of different inspiratory pressures. The effect of varying entrainment sites and inspiratory pressures (IPAP on PO2, PCO2, Fio2, inspiratory triggering and expiratory triggering in COPD patients is unknown. 18 patients with stable COPD (mean FEV1 47% participated in the study. Oxygen was added at 4 sites in the ventilatory circuit (site 1: between mask and exhalation port; site 2: just distal to exhalation port; site 3: at ventilator outlet; site 4: directly into the mask via an inlet. The effect of varying entrainment sites and inspiratory pressures on arterial PO2, PCO2, FIO2, was recorded at 3 mins. The same full face mask (Respironics, Image 3 & ventilator (Respironics, BIPAP ST 30 was used.

  15. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD

    Directory of Open Access Journals (Sweden)

    Formiga MF

    2018-05-01

    Full Text Available Magno F Formiga,1,2 Kathryn E Roach,1 Isabel Vital,3 Gisel Urdaneta,3 Kira Balestrini,3 Rafael A Calderon-Candelario,3,4 Michael A Campos,3,4,* Lawrence P Cahalin1,* 1Department of Physical Therapy, University of Miami Miller School of Medicine, Coral Gables, FL, USA; 2CAPES Foundation, Ministry of Education of Brazil, Brasilia, Brazil; 3Pulmonary Section, Miami Veterans Administration Medical Center, Miami, FL, USA; 4Division of Pulmonary, Allergy, Critical Care and Sleep Medicine, University of Miami Miller School of Medicine, Miami, FL, USA *These authors contributed equally to this work Purpose: The Test of Incremental Respiratory Endurance (TIRE provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP over time. The integration of MIP over inspiratory duration (ID provides the sustained maximal inspiratory pressure (SMIP. Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Patients and methods: Test–retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. Results: All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test–retest reliability with a nearly perfect intraclass correlation coefficient (ICC of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP

  16. Correlações entre variáveis respiratórias e funcionais na insuficiência cardíaca

    Directory of Open Access Journals (Sweden)

    Fábio Cangeri Di Naso

    2009-09-01

    Full Text Available Resumo: Fundamento: Alterações respiratórias podem in-fluenciar o desempenho funcional em doentes com insuficiência cardíaca (IC.Objectivo: Correlacionar a força muscular inspiratória máxima (PImax e as variáveis da função pulmonar com a capacidade funcional em doentes com IC.Métodos: Estudo transversal realizado de Janeiro a Julho de 2007 incluindo 42 doentes com IC crónica (28 ho-mens que não apresentavam doença pulmonar prévia. Os doentes pertenciam às classes funcionais I, II e III segundo a NYHA (New York Heart Association. As variáveis respiratórias mensuradas foram a PImax, a CVF (capacidade vital forçada e o VEF1(volume expiratório forçado no 1.º segundo. A distância percorrida no teste da caminhada dos seis minutos (TC6M, a classe funcional (CF e o domínio referente à capacidade funcional do questionário de qualidade de vida Short Form-36 (SF-36 foram as variáveis funcionais utilizadas.Resultados: A PImax correlacionou-se com a TC6M (r=0,543 e p<0,001, com a CF (r=-0,566 e p<0,001 e com a pontuação do domínio capacidade funcional do SF-36 (r=0,459 e p=0,002. O mesmo ocorre com a CVF e as variáveis TC6M (r=0,501 e p=0,001, CF (r=-0,477 e p=0,001 e SF-36 (r=0,314 e p=0,043. O VEF1 apresentou correlação com a TC6M (r=0,514 e p<0,001 e com a CF (r=-0,383 e p=0,012.Conclusão: Variáveis respiratórias referentes à função pulmonar e à força muscular inspiratória correlacio-nam com variáveis funcionais em doentes com IC.Rev Port Pneumol 2009; XV (5: 875-890 Abstract: Background: Respiratory alterations can impact on the functional performance of patients with heart failure.Aim: To correlate maximum inspiratory muscular force and lung function variables with functional capacity in heart failure patients.Methods: A transversal study January-July 2007 with 42 chronic heart disease patients (28 males with no prior

  17. Simplified design of IC amplifiers

    CERN Document Server

    Lenk, John

    1996-01-01

    Simplified Design of IC Amplifiers has something for everyone involved in electronics. No matter what skill level, this book shows how to design and experiment with IC amplifiers. For experimenters, students, and serious hobbyists, this book provides sufficient information to design and build IC amplifier circuits from 'scratch'. For working engineers who design amplifier circuits or select IC amplifiers, the book provides a variety of circuit configurations to make designing easier.Provides basics for all phases of practical design.Covers the most popular forms for amplif

  18. Horses Auto-Recruit Their Lungs by Inspiratory Breath Holding Following Recovery from General Anaesthesia.

    Directory of Open Access Journals (Sweden)

    Martina Mosing

    Full Text Available This study evaluated the breathing pattern and distribution of ventilation in horses prior to and following recovery from general anaesthesia using electrical impedance tomography (EIT. Six horses were anaesthetised for 6 hours in dorsal recumbency. Arterial blood gas and EIT measurements were performed 24 hours before (baseline and 1, 2, 3, 4, 5 and 6 hours after horses stood following anaesthesia. At each time point 4 representative spontaneous breaths were analysed. The percentage of the total breath length during which impedance remained greater than 50% of the maximum inspiratory impedance change (breath holding, the fraction of total tidal ventilation within each of four stacked regions of interest (ROI (distribution of ventilation and the filling time and inflation period of seven ROI evenly distributed over the dorso-ventral height of the lungs were calculated. Mixed effects multi-linear regression and linear regression were used and significance was set at p<0.05. All horses demonstrated inspiratory breath holding until 5 hours after standing. No change from baseline was seen for the distribution of ventilation during inspiration. Filling time and inflation period were more rapid and shorter in ventral and slower and longer in most dorsal ROI compared to baseline, respectively. In a mixed effects multi-linear regression, breath holding was significantly correlated with PaCO2 in both the univariate and multivariate regression. Following recovery from anaesthesia, horses showed inspiratory breath holding during which gas redistributed from ventral into dorsal regions of the lungs. This suggests auto-recruitment of lung tissue which would have been dependent and likely atelectic during anaesthesia.

  19. The effect of EC-IC bypass surgery on resting cerebral blood flow and cerebrovascular reserve capacity studied with stable Xe-CT and acetazolamide test

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, T.; Kashiwagi, S.; Nakano, S.; Takasago, T.; Abiko, S.; Shiroyama, Y.; Hayashi, M.; Ito, H. (Yamaguchi Univ. School of Medicine (Japan). Dept. of Neurosurgery)

    1991-06-01

    Cerebral blood flow (CBF) and cerebrovascular reserve capacity (CRC) were measured by stable xenon computerized tomography (Xe-CT) and acetazolamide test in 15 patients with cerebrovascular disease before and after extracranial-intracranial (EC-IC) bypass surgery for minor stroke, reversible ischemic neurological deficit or transient ischemic attack. All had angiographically shown occlusive lesions of the major arterial trunk. In the present series, global analysis showed that the bypass did not increase the resting rCBF, but did increase the rCRC. We divided the patients into four groups according to the preoperative resting rCBF and rCRC. All 3 patients with normal resting rCBF and reduced rCRC showed postoperative improvement of rCRC. Of 6 patients with reduced CBF and reduced CRC, three had postoperative increase in resting CBF and four had increased CRC. One of two patients with reduced CBF and normal CRC showed only an increase in CRC. We propose that reduced CRC or reduced CBF with reduced CRC are criteria for selection of candidates for bypass surgery. We conclude that Xe-CT with the Diamox test is a useful and simple method for evaluating cerebral hemodynamics. Preoperative grouping with a combination of preoperative resting rCBF and preoperative rCRC is useful for predicting the effect of EC-IC bypass surgery. (orig.).

  20. IC Treatment: Surgical Procedures

    Science.gov (United States)

    ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ...

  1. IC: Frequently Asked Questions

    Science.gov (United States)

    ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ...

  2. Laryngeal schwannoma in an 8-year-old boy with inspiratory dyspnea.

    Science.gov (United States)

    Rognone, Elisa; Rossi, Andrea; Conte, Massimo; Nozza, Paolo; Tarantino, Vincenzo; Fibbi, Antonio; Saetti, Roberto; Cutrone, Cesare; Tortori-Donati, Paolo

    2007-10-01

    Schwannomas of the larynx are rare lesions in the pediatric age group. In this article, we report on the neuroimaging features of a schwannoma arising from the left aryepiglottic fold in an 8-year-old boy with a 6-month history of inspiratory dyspnea. Neuroimaging showed a well-defined, avoid mass originating from the left aryepiglottic fold. The lesion was removed endoscopically. Complete removal of laryngeal schwannomas is curative, and adjuvant treatment is not required.

  3. Effect of PEEP, blood volume, and inspiratory hold maneuvers on venous return.

    Science.gov (United States)

    Berger, David; Moller, Per W; Weber, Alberto; Bloch, Andreas; Bloechlinger, Stefan; Haenggi, Matthias; Sondergaard, Soren; Jakob, Stephan M; Magder, Sheldon; Takala, Jukka

    2016-09-01

    According to Guyton's model of circulation, mean systemic filling pressure (MSFP), right atrial pressure (RAP), and resistance to venous return (RVR) determine venous return. MSFP has been estimated from inspiratory hold-induced changes in RAP and blood flow. We studied the effect of positive end-expiratory pressure (PEEP) and blood volume on venous return and MSFP in pigs. MSFP was measured by balloon occlusion of the right atrium (MSFPRAO), and the MSFP obtained via extrapolation of pressure-flow relationships with airway occlusion (MSFPinsp_hold) was extrapolated from RAP/pulmonary artery flow (QPA) relationships during inspiratory holds at PEEP 5 and 10 cmH2O, after bleeding, and in hypervolemia. MSFPRAO increased with PEEP [PEEP 5, 12.9 (SD 2.5) mmHg; PEEP 10, 14.0 (SD 2.6) mmHg, P = 0.002] without change in QPA [2.75 (SD 0.43) vs. 2.56 (SD 0.45) l/min, P = 0.094]. MSFPRAO decreased after bleeding and increased in hypervolemia [10.8 (SD 2.2) and 16.4 (SD 3.0) mmHg, respectively, P waterfall. Copyright © 2016 the American Physiological Society.

  4. Increased long-term mortality after a high perioperative inspiratory oxygen fraction during abdominal surgery

    DEFF Research Database (Denmark)

    Meyhoff, Christian Sylvest; Jorgensen, Lars N; Wetterslev, Jørn

    2012-01-01

    A high perioperative inspiratory oxygen fraction (80%) has been recommended to prevent postoperative wound infections. However, the most recent and one of the largest trials, the PROXI trial, found no reduction in surgical site infection, and 30-day mortality was higher in patients given 80% oxygen...

  5. Objective measurement of inhaler inhalation flow profile using acoustic methods

    Energy Technology Data Exchange (ETDEWEB)

    Lacalle, H.; Taylor, T.E.; Marco, S.; Reilly, R.B.

    2016-07-01

    Patients with asthma and chronic obstructive pulmonary diseases (COPD) are mostly treated with inhalers that deliver medication directly to their airways. Drug delivery from dry powder inhalers (DPIs) is very much reliant on the inhalation manoeuvre, specifically the peak inspiratory flow rate (PIFR), inspiratory capacity (IC) and inhalation rise time (IRT) of the inhalation. It has been widely reported that patients may not follow correct inhalation technique while using their inhaler. In this study, a novel acoustic method is proposed to accurately estimate inhalation flow profile using only one inhalation recording for calibration. An Ellipta DPI was placed inside an airtight container with a spirometer connected in order to measure inhalation flow parameters. An acoustic recording device (Inhaler Compliance Assessment (INCA)) was also attached to the DPI. Inhalation audio and flow signals were recorded simultaneously. The data were collected from 20 healthy subjects while performing inhaler inhalations at a range of inspiratory flow rates. A power law regression model was computed to obtain the relationship between the acoustic envelope of the inhalation and flow profile of each recording. Each model was tested on the remaining audio signals to estimate flow profile. The average estimation error was found to be 10.5±0.3% for estimating flow profile from audio signals. Inhalation flow profile parameters (PIFR, IC and IRT) could then be measured from the estimated flow profile with high accuracy giving information on user inhalation technique. This method may assist in improving patient inhaler adherence and overall disease control. (Author)

  6. LD to IC

    CERN Multimedia

    Association du personnel

    2010-01-01

    LC to IC – Publication of posts: Following the publication of new LD to IC posts, we regret that a large number of post descriptions are not available in both CERN official languages, English and French. Consequently, the Staff Association has decided to provide assistance to those who need it with the translation of one or more posts of interest. To do this, please contact the Staff Association secretariat, tel. 72819 or 72761 or 74224.

  7. Evaluation of lung volumes, vital capacity and respiratory muscle strength after cervical, thoracic and lumbar spinal surgery.

    Science.gov (United States)

    Oliveira, Marcio Aparecido; Vidotto, Milena Carlos; Nascimento, Oliver Augusto; Almeida, Renato; Santoro, Ilka Lopes; Sperandio, Evandro Fornias; Jardim, José Roberto; Gazzotti, Mariana Rodrigues

    2015-01-01

    Studies have shown that physiopathological changes to the respiratory system can occur following thoracic and abdominal surgery. Laminectomy is considered to be a peripheral surgical procedure, but it is possible that thoracic spinal surgery exerts a greater influence on lung function. The aim of this study was to evaluate the pulmonary volumes and maximum respiratory pressures of patients undergoing cervical, thoracic or lumbar spinal surgery. Prospective study in a tertiary-level university hospital. Sixty-three patients undergoing laminectomy due to diagnoses of tumors or herniated discs were evaluated. Vital capacity, tidal volume, minute ventilation and maximum respiratory pressures were evaluated preoperatively and on the first and second postoperative days. Possible associations between the respiratory variables and the duration of the operation, surgical diagnosis and smoking status were investigated. Vital capacity and maximum inspiratory pressure presented reductions on the first postoperative day (20.9% and 91.6%, respectively) for thoracic surgery (P = 0.01), and maximum expiratory pressure showed reductions on the first postoperative day in cervical surgery patients (15.3%; P = 0.004). The incidence of pulmonary complications was 3.6%. There were reductions in vital capacity and maximum respiratory pressures during the postoperative period in patients undergoing laminectomy. Surgery in the thoracic region was associated with greater reductions in vital capacity and maximum inspiratory pressure, compared with cervical and lumbar surgery. Thus, surgical manipulation of the thoracic region appears to have more influence on pulmonary function and respiratory muscle action.

  8. The oiling of ICS

    International Nuclear Information System (INIS)

    Hunter, S.

    1993-01-01

    The incident command system (ICS) works for oil spills. It should be the industry standard and some will argue that it already is. But there are a number of temptations to fiddle with it. Fueling these inclinations is the fundamental difference between oil spills and natural disasters: Oil spills make the perpetrator fix the problem - under heavy oversight. Add to this difference the public outcry that attends oil spills and the dual role of government as both helper and prosecutor. From these conditions emerge adaptations of ICS which both weaken and strengthen it. The benefits of ICS are diminished by deputy incident commanders who block unified commanders from access to section chiefs, over-zealous crisis managers who displace command post decisions or its information office, separate press offices with party line slants, government law enforcement activity mixed into spill response, nonstandard operations terminology and structure involving open-quotes containment and clean upclose quotes or open-quotes salvage,close quotes and the commingling of public and private response funds. ICS's application to oil spill response is strengthened by the use of trained unified commanders, deputy incident commanders who operate as staff rather than line, crisis managers who support on-scene objectives, joint information centers, and heavy involvement of skilled, prepared environmental assessment teams in the planning section who generate priorities, strategies, and (operationally coordinated) tactics. Technically, not all these points constitute alterations of ICS, but most do and the others come close. This mixed bag of strengthening and weakening tweaks to oil spill ICS provides an opportunity to take a new look at this faithful friend to the crisis responder

  9. Determinants of dynamic hyperinflation during metronome-paced tachypnea in COPD and normal subjects.

    Science.gov (United States)

    Cooper, C B; Calligaro, G L; Quinn, M M; Eshaghian, P; Coskun, F; Abrazado, M; Bateman, E D; Raine, R I

    2014-01-01

    In COPD, dynamic hyperinflation (DH) occurs during exercise and during metronome-paced tachypnea (MPT). We investigated the relationship of DH with breathing pattern and ventilation (V˙E) in COPD and normal subjects (NS). In 35 subjects with moderate COPD and 17 younger healthy volunteers we measured inspiratory capacity (IC), breathing frequency (fR), expiratory time (TE), ventilation (V˙E) and end-tidal carbon dioxide tension (PETCO2) at baseline and after 30s of MPT at 40breaths/min with metronome-defined I:E ratios of 1:1 and 1:2. A reduction in ICIC) was taken to indicate DH. In COPD subjects, DH correlated with TE but not with V˙E or PETCO2, and was best predicted by total lung capacity. NS also showed DH (although less than in COPD), which correlated with PETCO2 but not with fR, TE or V˙E. We conclude that MPT evokes DH in both NS and patients with COPD. TE is the most important determinant of DH during MPT in patients with COPD. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Recommendations for the measurement of FIV(1) values in chronic obstructive pulmonary disease.

    NARCIS (Netherlands)

    Visser, F.J.; Ramlal, S.; Dekhuijzen, P.N.R.; Heijdra, Y.F.

    2008-01-01

    BACKGROUND: In contrast to static inspiratory parameters such as vital capacity and inspiratory capacity, information on forced inspiratory volume in 1 s (FIV(1)) in patients with chronic obstructive pulmonary disease (COPD) is limited. OBJECTIVES: It was the aim of this study to investigate the

  11. Radiologic total lung capacity measurement. Development and evaluation of a computer-based system

    Energy Technology Data Exchange (ETDEWEB)

    Seeley, G.W.; Mazzeo, J.; Borgstrom, M.; Hunter, T.B.; Newell, J.D.; Bjelland, J.C.

    1986-11-01

    The development of a computer-based radiologic total lung capacity (TLC) measurement system designed to be used by non-physician personnel is detailed. Four operators tested the reliability and validity of the system by measuring inspiratory PA and lateral pediatric chest radiographs with a Graf spark pen interfaced to a DEC VAX 11/780 computer. First results suggest that the ultimate goal of developing an accurate and easy to use TLC measurement system for non-physician personnel is attainable.

  12. Increasing the inspiratory time and I:E ratio during mechanical ventilation aggravates ventilator-induced lung injury in mice.

    Science.gov (United States)

    Müller-Redetzky, Holger C; Felten, Matthias; Hellwig, Katharina; Wienhold, Sandra-Maria; Naujoks, Jan; Opitz, Bastian; Kershaw, Olivia; Gruber, Achim D; Suttorp, Norbert; Witzenrath, Martin

    2015-01-28

    Lung-protective ventilation reduced acute respiratory distress syndrome (ARDS) mortality. To minimize ventilator-induced lung injury (VILI), tidal volume is limited, high plateau pressures are avoided, and positive end-expiratory pressure (PEEP) is applied. However, the impact of specific ventilatory patterns on VILI is not well defined. Increasing inspiratory time and thereby the inspiratory/expiratory ratio (I:E ratio) may improve oxygenation, but may also be harmful as the absolute stress and strain over time increase. We thus hypothesized that increasing inspiratory time and I:E ratio aggravates VILI. VILI was induced in mice by high tidal-volume ventilation (HVT 34 ml/kg). Low tidal-volume ventilation (LVT 9 ml/kg) was used in control groups. PEEP was set to 2 cm H2O, FiO2 was 0.5 in all groups. HVT and LVT mice were ventilated with either I:E of 1:2 (LVT 1:2, HVT 1:2) or 1:1 (LVT 1:1, HVT 1:1) for 4 hours or until an alternative end point, defined as mean arterial blood pressure below 40 mm Hg. Dynamic hyperinflation due to the increased I:E ratio was excluded in a separate group of animals. Survival, lung compliance, oxygenation, pulmonary permeability, markers of pulmonary and systemic inflammation (leukocyte differentiation in lung and blood, analyses of pulmonary interleukin-6, interleukin-1β, keratinocyte-derived chemokine, monocyte chemoattractant protein-1), and histopathologic pulmonary changes were analyzed. LVT 1:2 or LVT 1:1 did not result in VILI, and all individuals survived the ventilation period. HVT 1:2 decreased lung compliance, increased pulmonary neutrophils and cytokine expression, and evoked marked histologic signs of lung injury. All animals survived. HVT 1:1 caused further significant worsening of oxygenation, compliance and increased pulmonary proinflammatory cytokine expression, and pulmonary and blood neutrophils. In the HVT 1:1 group, significant mortality during mechanical ventilation was observed. According to the "baby lung

  13. Physiologic effects of alveolar recruitment and inspiratory pauses during moderately-high-frequency ventilation delivered by a conventional ventilator in a severe lung injury model.

    Directory of Open Access Journals (Sweden)

    Ricardo Luiz Cordioli

    Full Text Available To investigate whether performing alveolar recruitment or adding inspiratory pauses could promote physiologic benefits (VT during moderately-high-frequency positive pressure ventilation (MHFPPV delivered by a conventional ventilator in a porcine model of severe acute respiratory distress syndrome (ARDS.Prospective experimental laboratory study with eight pigs. Induction of acute lung injury with sequential pulmonary lavages and injurious ventilation was initially performed. Then, animals were ventilated on a conventional mechanical ventilator with a respiratory rate (RR = 60 breaths/minute and PEEP titrated according to ARDS Network table. The first two steps consisted of a randomized order of inspiratory pauses of 10 and 30% of inspiratory time. In final step, we removed the inspiratory pause and titrated PEEP, after lung recruitment, with the aid of electrical impedance tomography. At each step, PaCO2 was allowed to stabilize between 57-63 mmHg for 30 minutes.The step with RR of 60 after lung recruitment had the highest PEEP when compared with all other steps (17 [16,19] vs 14 [10, 17]cmH2O, but had lower driving pressures (13 [13,11] vs 16 [14, 17]cmH2O, higher P/F ratios (212 [191,243] vs 141 [105, 184] mmHg, lower shunt (23 [20, 23] vs 32 [27, 49]%, lower dead space ventilation (10 [0, 15] vs 30 [20, 37]%, and a more homogeneous alveolar ventilation distribution. There were no detrimental effects in terms of lung mechanics, hemodynamics, or gas exchange. Neither the addition of inspiratory pauses or the alveolar recruitment maneuver followed by decremental PEEP titration resulted in further reductions in VT.During MHFPPV set with RR of 60 bpm delivered by a conventional ventilator in severe ARDS swine model, neither the inspiratory pauses or PEEP titration after recruitment maneuver allowed reduction of VT significantly, however the last strategy decreased driving pressures and improved both shunt and dead space.

  14. The Implications Related to Different IC, Different Projects and Different Thinking Addressing the Common Core of IC

    DEFF Research Database (Denmark)

    Lindgren, Peter; Saghaug, Kristin Margrethe

    2009-01-01

    challenge the development of IC: - The IC at the organizational level seems to diminish when innovation gets highly dispersed and is operated outside the core of the organization - The attractiveness of the organization to different ICA, which is one fundament to sustainable and successful innovation, seems...... to fall when the IC at the organizational core level diminishes The objective of this paper is therefore to understand 1) How the IC at the organizational core level may continue to be developed, when at the same time innovation is taking place in dispersed groups and projects. 2) How to motivate...... the different ICA´s to bring learning and knowledge back to the core with the purpose to develop IC at the organizational core level....

  15. Irregular Dwarf Galaxy IC 1613

    Science.gov (United States)

    2005-01-01

    Ultraviolet image (left) and visual image (right) of the irregular dwarf galaxy IC 1613. Low surface brightness galaxies, such as IC 1613, are more easily detected in the ultraviolet because of the low background levels compared to visual wavelengths.

  16. Functional capacity and muscular abnormalities in subclinical hypothyroidism.

    Science.gov (United States)

    Reuters, Vaneska S; Teixeira, Patrícia de Fátima S; Vigário, Patrícia S; Almeida, Cloyra P; Buescu, Alexandre; Ferreira, Márcia M; de Castro, Carmen L N; Gold, Jaime; Vaisman, Mario

    2009-10-01

    Neuromuscular abnormalities and low exercise tolerance are frequently observed in overt hypothyroidism, but it remains controversial if they can also occur in subclinical hypothyroidism (sHT). The aim of this study is to evaluate neuromuscular symptoms, muscle strength, and exercise capacity in sHT, compared with healthy euthyroid individuals. A cross-sectional study was performed with 44 sHT and 24 euthyroid outpatients from a university hospital. Neuromuscular symptoms were questioned. Muscle strength was tested for neck, shoulder, arm, and hip muscle groups, using manual muscle testing (MMT). Quadriceps muscle strength was tested with a chair dynamometer and inspiratory muscle strength (IS) by a manuvacuometer. Functional capacity was estimated based on the peak of oxygen uptake (mL/kg/min), using the Bruce treadmill protocol. Cramps (54.8% versus 25.0%; P muscle strength by MMT and the coexistence of neuromuscular complaints in patients with sHT may indicate neuromuscular dysfunction.

  17. Utility of the inspiratory phase in high-resolution computed tomography evaluations of pediatric patients with bronchiolitis obliterans after allogeneic bone marrow transplant: reducing patient radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Togni Filho, Paulo Henrique; Casagrande, Joao Luiz Marin; Lederman, Henrique Manoel, E-mail: paulotognifilho@gmail.com [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Dept. of Diagnostico por Imagem; Universidade de Sao Paulo (InRad/HC/FMUSP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Instituto de Radiologia

    2017-03-15

    Objective: To evaluate the utility of the inspiratory phase in high-resolution computed tomography (HRCT) of the chest for the diagnosis of post-bone marrow transplantation bronchiolitis obliterans. Materials and Methods: This was a retrospective, observational, cross-sectional study. We selected patients of either gender who underwent bone marrow transplantation and chest HRCT between March 1, 2002 and December 12, 2014. Ages ranged from 3 months to 20.7 years. We included all examinations in which the HRCT was performed appropriately. The examinations were read by two radiologists, one with extensive experience in pediatric radiology and another in the third year of residency, who determined the presence or absence of the following imaging features: air trapping, bronchiectasis, alveolar opacities, nodules, and atelectasis. Results: A total of 222 examinations were evaluated (mean, 5.4 ± 4.5 examinations per patient). The expiratory phase findings were comparable to those obtained in the inspiratory phase, except in one patient, in whom a small uncharacteristic nodule was identified only in the inspiratory phase. Air trapping was identified in a larger number of scans in the expiratory phase than in the inspiratory phase, as was atelectasis, although the difference was statistically significant only for air trapping. Conclusion: In children being evaluated for post-bone marrow transplantation bronchiolitis obliterans, the inspiratory phase can be excluded from the chest HRCT protocol, thus reducing by half the radiation exposure in this population. (author)

  18. Utility of the inspiratory phase in high-resolution computed tomography evaluations of pediatric patients with bronchiolitis obliterans after allogeneic bone marrow transplant: reducing patient radiation exposure

    International Nuclear Information System (INIS)

    Togni Filho, Paulo Henrique; Casagrande, Joao Luiz Marin; Lederman, Henrique Manoel; Universidade de Sao Paulo

    2017-01-01

    Objective: To evaluate the utility of the inspiratory phase in high-resolution computed tomography (HRCT) of the chest for the diagnosis of post-bone marrow transplantation bronchiolitis obliterans. Materials and Methods: This was a retrospective, observational, cross-sectional study. We selected patients of either gender who underwent bone marrow transplantation and chest HRCT between March 1, 2002 and December 12, 2014. Ages ranged from 3 months to 20.7 years. We included all examinations in which the HRCT was performed appropriately. The examinations were read by two radiologists, one with extensive experience in pediatric radiology and another in the third year of residency, who determined the presence or absence of the following imaging features: air trapping, bronchiectasis, alveolar opacities, nodules, and atelectasis. Results: A total of 222 examinations were evaluated (mean, 5.4 ± 4.5 examinations per patient). The expiratory phase findings were comparable to those obtained in the inspiratory phase, except in one patient, in whom a small uncharacteristic nodule was identified only in the inspiratory phase. Air trapping was identified in a larger number of scans in the expiratory phase than in the inspiratory phase, as was atelectasis, although the difference was statistically significant only for air trapping. Conclusion: In children being evaluated for post-bone marrow transplantation bronchiolitis obliterans, the inspiratory phase can be excluded from the chest HRCT protocol, thus reducing by half the radiation exposure in this population. (author)

  19. Relation of exercise capacity with lung volumes before and after 6-minute walk test in subjects with COPD.

    Science.gov (United States)

    Wibmer, Thomas; Rüdiger, Stefan; Kropf-Sanchen, Cornelia; Stoiber, Kathrin M; Rottbauer, Wolfgang; Schumann, Christian

    2014-11-01

    There is growing evidence that exercise-induced variation in lung volumes is an important source of ventilatory limitation and is linked to exercise intolerance in COPD. The aim of this study was to compare the correlations of walk distance and lung volumes measured before and after a 6-min walk test (6MWT) in subjects with COPD. Forty-five subjects with stable COPD (mean pre-bronchodilator FEV1: 47 ± 18% predicted) underwent a 6MWT. Body plethysmography was performed immediately pre- and post-6MWT. Correlations were generally stronger between 6-min walk distance and post-6MWT lung volumes than between 6-min walk distance and pre-6MWT lung volumes, except for FEV1. These differences in Pearson correlation coefficients were significant for residual volume expressed as percent of total lung capacity (-0.67 vs -0.58, P = .043), percent of predicted residual volume expressed as percent of total lung capacity (-0.68 vs -0.59, P = .026), inspiratory vital capacity (0.65 vs 0.54, P = .019), percent of predicted inspiratory vital capacity (0.49 vs 0.38, P = .037), and percent of predicted functional residual capacity (-0.62 vs -0.47, P = .023). In subjects with stable COPD, lung volumes measured immediately after 6MWT are more closely related to exercise limitation than baseline lung volumes measured before 6MWT, except for FEV1. Therefore, pulmonary function testing immediately after exercise should be included in future studies on COPD for the assessment of exercise-induced ventilatory constraints to physical performance that cannot be adequately assessed from baseline pulmonary function testing at rest. Copyright © 2014 by Daedalus Enterprises.

  20. Complement fixation by solid phase immune complexes. Reduced capacity in SLE sera

    DEFF Research Database (Denmark)

    Baatrup, G; Jonsson, H; Sjöholm, A

    1988-01-01

    We describe an ELISA for assessment of complement function based on the capacity of serum to support fixation of complement components to solid phase immune complexes (IC). Microplates were coated with aggregated bovine serum albumin (BSA) followed by rabbit anti-BSA IgG. The solid phase IC were...

  1. Changes in Cross-Sectional Area and Transverse Diameter of the Heart on Inspiratory and Expiratory Chest CT: Correlation with Changes in Lung Size and Influence on Cardiothoracic Ratio Measurement.

    Directory of Open Access Journals (Sweden)

    Hayato Tomita

    Full Text Available The aim of this study was to investigate physiological changes in cardiac area and diameters between inspiratory and expiratory chest computed tomography (CT, and to assess their correlation with lung size change and influence on cardiothoracic ratio (CTR measurements.The institutional review board of our institution approved this study, and informed consent was waived. Forty-three subjects underwent inspiratory and expiratory chest CT as part of routine clinical care. On both inspiratory and expiratory scans, lung volumes and maximum lung diameters (transverse and vertical directions were measured. The maximum cardiac cross-sectional area (CSA and the maximum transverse cardiac diameter were measured on both scans, and the CT-based CTR was calculated. Changes in the lung and cardiac measurements were expressed as the expiratory/inspiratory (E/I ratios. Comparisons between inspiratory and expiratory measurements were made by the Wilcoxon signed-rank test. Correlations between the E/I ratios of lung and heart measurements were evaluated by Spearman's rank correlation analysis.Cardiac CSA and transverse cardiac diameter was significantly larger on expiratory than on inspiratory CT (p < 0.0001. Significant negative correlations were found between the E/I ratios of these cardiac measurements and the E/I ratios of lung volume and vertical lung diameter (p < 0.01. CT-based CTR was significantly larger on expiration than on inspiration (p < 0.0001.Heart size on chest CT depends on the phase of ventilation, and is correlated with changes in lung volume and craniocaudal lung diameter. The CTR is also significantly influenced by ventilation.

  2. Reduced Inspiratory Muscle Strength in Patients with Type 2 Diabetes Mellitus and Obstructive Sleep Apnoea

    DEFF Research Database (Denmark)

    Rehling, Thomas; Banghoj, Anne Margareta; Kristiansen, Marie Hvelplund

    2017-01-01

    Background: Obstructive sleep apnoea (OSA) is related to type 2 diabetes (T2DM), and it may be associated with reduced inspiratory muscle strength (IMS). The aim of this study was to investigate the IMS in patients with T2DM, with or without OSA. Methods: Patients with T2DM with OSA (n = 33...

  3. Medicinal clays improve the endurance of loaded inspiratory muscles in COPD: a randomized clinical trial of nonpharmacological treatment

    Directory of Open Access Journals (Sweden)

    Baldi S

    2015-10-01

    Full Text Available Simonetta Baldi,1 Gian Domenico Pinna,2 Claudio Bruschi,1 Fabrizio Caldara,3 Roberto Maestri,2 Elena Dacosto,1 Antonella Rezzani,1 Ermanno Popovich,1 Ezio Bellinzona,1 Paola Crotti,1 Silvia Montemartini,1 Claudio Fracchia1 1Department of Pneumology, 2Department of Biomedical Engineering, Scientific Institute of Montescano, Salvatore Maugeri Foundation, Istituto Di Ricovero e Cura a Carattere Scientifico, Montescano (Pavia, 3Center of Thermal Studies Pietro d’Abano, AbanoTerme, Padua, Italy Background: Inspiratory resistive breathing (IRB challenges affect respiratory muscle endurance in healthy individuals, which is considered to be an interleukin 6 (IL-6–dependent mechanism. Whether nonpharmacological thermal therapies promote the endurance of loaded inspiratory muscles in chronic obstructive pulmonary disease (COPD is unclear. The objectives of this study were to compare the effects of two thermal interventions on endurance time (ET and plasma IL-6 concentration following an IRB challenge.Methods: This study was a randomized, parallel-group, unblinded clinical trial in a single-center setting. Forty-two patients (aged 42–76 years suffering from mild to severe COPD participated in this study. Both groups completed 12 sessions of the mud bath therapy (MBT (n=22 or leisure thermal activity (LTA (n=19 in a thermal spa center in Italy. Pre- and postintervention spirometry, maximum inspiratory pressure, and plasma mediators were obtained and ET and endurance oxygen expenditure (VO2Endur were measured following IRB challenge at 40% of maximum inspiratory pressure.Results: There was no difference in ΔIL-6 between the intervention groups. But, IRB challenge increased cytokine IL-6 plasma levels systematically. The effect size was small. A statistically significant treatment by IRB challenge effect existed in ET, which significantly increased in the MBT group (P=0.003. In analysis of covariance treatment by IRB challenge analysis with LnVO2

  4. Reference Values for Inspiratory Muscle Endurance in Healthy Children and Adolescents.

    Directory of Open Access Journals (Sweden)

    Cristhiele Taís Woszezenki

    Full Text Available To generate reference values for two inspiratory muscle endurance (IME protocols in healthy children and adolescents.This is an observational, cross-sectional study, in healthy children and adolescents from 4 to 18 years of age. Weight, height, maximal inspiratory pressure (MIP and IME were measured using two protocols. A fixed load of 30% of MIP with a 10% increment every 2 minutes was used in the incremental threshold loading protocol. As for the maximal loading protocol, a fixed load of 70% of MIP was used and the time limit (Tlim achieved until fatigue was measured.A total of 462 participants were included, 281 corresponding to the incremental loading protocol and 181 to maximal loading. There were moderate and positive correlations between IME and age, MIP, weight and height in the incremental threshold loading. However, the regression model demonstrated that MIP and age were the best variables to predict the IME. Otherwise, weak and positive correlations with age, weight and height were found in the maximal loading. Only age and height influenced endurance in the regression model. The predictive power (r2 of the incremental threshold loading protocol was 0.65, while the maximal loading was 0.15. The reproducibility measured by the intraclass correlation coefficient (ICC was higher in the incremental loading (0.96 compared to the maximal loading test (0.69.IME in healthy children and adolescents can be explained by age, height and MIP. The incremental threshold loading protocol showed more reliable results and should be the model of choice to evaluate IME in the pediatric age group.

  5. Wafer level 3-D ICs process technology

    CERN Document Server

    Tan, Chuan Seng; Reif, L Rafael

    2009-01-01

    This book focuses on foundry-based process technology that enables the fabrication of 3-D ICs. The core of the book discusses the technology platform for pre-packaging wafer lever 3-D ICs. However, this book does not include a detailed discussion of 3-D ICs design and 3-D packaging. This is an edited book based on chapters contributed by various experts in the field of wafer-level 3-D ICs process technology. They are from academia, research labs and industry.

  6. Chronic and acute inspiratory muscle loading augment the effect of a 6-week interval program on tolerance of high-intensity intermittent bouts of running.

    Science.gov (United States)

    Tong, Tom K; Fu, Frank H; Eston, Roger; Chung, Pak-Kwong; Quach, Binh; Lu, Kui

    2010-11-01

    This study examined the hypothesis that chronic (training) and acute (warm-up) loaded ventilatory activities applied to the inspiratory muscles (IM) in an integrated manner would augment the training volume of an interval running program. This in turn would result in additional improvement in the maximum performance of the Yo-Yo intermittent recovery test in comparison with interval training alone. Eighteen male nonprofessional athletes were allocated to either an inspiratory muscle loading (IML) group or control group. Both groups participated in a 6-week interval running program consisting of 3-4 workouts (1-3 sets of various repetitions of selected distance [100-2,400 m] per workout) per week. For the IML group, 4-week IM training (30 inspiratory efforts at 50% maximal static inspiratory pressure [P0] per set, 2 sets·d-1, 6 d·wk-1) was applied before the interval program. Specific IM warm-up (2 sets of 30 inspiratory efforts at 40% P0) was performed before each workout of the program. For the control group, neither IML was applied. In comparison with the control group, the interval training volume as indicated by the repeatability of running bouts at high intensity was approximately 27% greater in the IML group. Greater increase in the maximum performance of the Yo-Yo test (control: 16.9 ± 5.5%; IML: 30.7 ± 4.7% baseline value) was also observed after training. The enhanced exercise performance was partly attributable to the greater reductions in the sensation of breathlessness and whole-body metabolic stress during the Yo-Yo test. These findings show that the combination of chronic and acute IML into a high-intensity interval running program is a beneficial training strategy for enhancing the tolerance to high-intensity intermittent bouts of running.

  7. TU-CD-BRA-11: Application of Bone Suppression Technique to Inspiratory/expiratory Chest Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, R; Sanada, S [Kanazawa University, Kanazawa, Ishikawa (Japan); Sakuta, K; Kawashima, H [Kanazawa University Hospital, Kanazawa, Ishikawa (Japan); Kishitani, Y [TOYO Corporation, Chuoh-ku, Tokyo (Japan)

    2015-06-15

    Purpose: The bone suppression technique based on advanced image processing can suppress the conspicuity of bones on chest radiographs, creating soft tissue images normally obtained by the dual-energy subtraction technique. This study was performed to investigate the usefulness of bone suppression technique in quantitative analysis of pulmonary function in inspiratory/expiratory chest radiography. Methods: Commercial bone suppression image processing software (ClearRead; Riverain Technologies) was applied to paired inspiratory/expiratory chest radiographs of 107 patients (normal, 33; abnormal, 74) to create corresponding bone suppression images. The abnormal subjects had been diagnosed with pulmonary diseases, such as pneumothorax, pneumonia, emphysema, asthma, and lung cancer. After recognition of the lung area, the vectors of respiratory displacement were measured in all local lung areas using a cross-correlation technique. The measured displacement in each area was visualized as displacement color maps. The distribution pattern of respiratory displacement was assessed by comparison with the findings of lung scintigraphy. Results: Respiratory displacement of pulmonary markings (soft tissues) was able to be quantified separately from the rib movements on bone suppression images. The resulting displacement map showed a left-right symmetric distribution increasing from the lung apex to the bottom region of the lung in many cases. However, patients with ventilatory impairments showed a nonuniform distribution caused by decreased displacement of pulmonary markings, which were confirmed to correspond to area with ventilatory impairments found on the lung scintigrams. Conclusion: The bone suppression technique was useful for quantitative analysis of respiratory displacement of pulmonary markings without any interruption of the rib shadows. Abnormal areas could be detected as decreased displacement of pulmonary markings. Inspiratory/expiratory chest radiography combined

  8. Influences of Duration of Inspiratory Effort, Respiratory Mechanics, and Ventilator Type on Asynchrony With Pressure Support and Proportional Assist Ventilation.

    Science.gov (United States)

    Vasconcelos, Renata S; Sales, Raquel P; Melo, Luíz H de P; Marinho, Liégina S; Bastos, Vasco Pd; Nogueira, Andréa da Nc; Ferreira, Juliana C; Holanda, Marcelo A

    2017-05-01

    Pressure support ventilation (PSV) is often associated with patient-ventilator asynchrony. Proportional assist ventilation (PAV) offers inspiratory assistance proportional to patient effort, minimizing patient-ventilator asynchrony. The objective of this study was to evaluate the influence of respiratory mechanics and patient effort on patient-ventilator asynchrony during PSV and PAV plus (PAV+). We used a mechanical lung simulator and studied 3 respiratory mechanics profiles (normal, obstructive, and restrictive), with variations in the duration of inspiratory effort: 0.5, 1.0, 1.5, and 2.0 s. The Auto-Trak system was studied in ventilators when available. Outcome measures included inspiratory trigger delay, expiratory trigger asynchrony, and tidal volume (V T ). Inspiratory trigger delay was greater in the obstructive respiratory mechanics profile and greatest with a effort of 2.0 s (160 ms); cycling asynchrony, particularly delayed cycling, was common in the obstructive profile, whereas the restrictive profile was associated with premature cycling. In comparison with PSV, PAV+ improved patient-ventilator synchrony, with a shorter triggering delay (28 ms vs 116 ms) and no cycling asynchrony in the restrictive profile. V T was lower with PAV+ than with PSV (630 mL vs 837 mL), as it was with the single-limb circuit ventilator (570 mL vs 837 mL). PAV+ mode was associated with longer cycling delays than were the other ventilation modes, especially for the obstructive profile and higher effort values. Auto-Trak eliminated automatic triggering. Mechanical ventilation asynchrony was influenced by effort, respiratory mechanics, ventilator type, and ventilation mode. In PSV mode, delayed cycling was associated with shorter effort in obstructive respiratory mechanics profiles, whereas premature cycling was more common with longer effort and a restrictive profile. PAV+ prevented premature cycling but not delayed cycling, especially in obstructive respiratory mechanics

  9. Maximum inspiratory pressure as a clinically meaningful trial endpoint for neuromuscular diseases: A comprehensive review of the literature

    NARCIS (Netherlands)

    B. Schoser; Fong, E. (Edward); Geberhiwot, T. (Tarekegn); Hughes, D. (Derralynn); Kissel, J.T. (John T.); Madathil, S.C. (Shyam C.); Orlikowski, D. (David); Polkey, M.I. (Michael I.); M. Roberts (Mark); H.A.W.M. Tiddens (Harm); Young, P. (Peter)

    2017-01-01

    textabstractRespiratory muscle strength is a proven predictor of long-term outcome of neuromuscular disease (NMD), including amyotrophic lateral sclerosis, Duchenne muscular dystrophy, and spinal muscular atrophy. Maximal inspiratory pressure (MIP), a sensitive measure of respiratory muscle

  10. Impaired cortical processing of inspiratory loads in children with chronic respiratory defects

    Directory of Open Access Journals (Sweden)

    Clément Annick

    2007-09-01

    Full Text Available Abstract Background Inspiratory occlusion evoked cortical potentials (the respiratory related-evoked potentials, RREPs bear witness of the processing of changes in respiratory mechanics by the brain. Their impairment in children having suffered near-fatal asthma supports the hypothesis that relates asthma severity with the ability of the patients to perceive respiratory changes. It is not known whether or not chronic respiratory defects are associated with an alteration in brain processing of inspiratory loads. The aim of the present study was to compare the presence, the latencies and the amplitudes of the P1, N1, P2, and N2 components of the RREPs in children with chronic lung or neuromuscular disease. Methods RREPs were recorded in patients with stable asthma (n = 21, cystic fibrosis (n = 32, and neuromuscular disease (n = 16 and in healthy controls (n = 11. Results The 4 RREP components were significantly less frequently observed in the 3 groups of patients than in the controls. Within the patient groups, the N1 and the P2 components were significantly less frequently observed in the patients with asthma (16/21 for both components and cystic fibrosis (20/32 and 14/32 than in the patients with neuromuscular disease (15/16 and 16/16. When present, the latencies and amplitudes of the 4 components were similar in the patients and controls. Conclusion Chronic ventilatory defects in children are associated with an impaired cortical processing of afferent respiratory signals.

  11. SEM probe of IC radiation sensitivity

    Science.gov (United States)

    Gauthier, M. K.; Stanley, A. G.

    1979-01-01

    Scanning Electron Microscope (SEM) used to irradiate single integrated circuit (IC) subcomponent to test for radiation sensitivity can localize area of IC less than .03 by .03 mm for determination of exact location of radiation sensitive section.

  12. Dicty_cDB: FC-IC0102 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC-IC (Link to library) FC-IC0102 (Link to dictyBase) - - - Contig-U16527-1 FC-IC01...02F (Link to Original site) FC-IC0102F 434 - - - - - - Show FC-IC0102 Library FC-IC (Link to library) Clone ...ID FC-IC0102 (Link to dictyBase) Atlas ID - NBRP ID - dictyBase ID - Link to Contig Contig-U16527-1 Original site URL http://dict... (bits) Value N AB088483 |AB088483.1 Dictyostelium discoideum gene for gamete and mating-type specific prote...oducing significant alignments: (bits) Value AB088483_1( AB088483 |pid:none) Dictyostelium discoideum gmsA g

  13. Peripheral chemoreceptors tune inspiratory drive via tonic expiratory neuron hubs in the medullary ventral respiratory column network.

    Science.gov (United States)

    Segers, L S; Nuding, S C; Ott, M M; Dean, J B; Bolser, D C; O'Connor, R; Morris, K F; Lindsey, B G

    2015-01-01

    Models of brain stem ventral respiratory column (VRC) circuits typically emphasize populations of neurons, each active during a particular phase of the respiratory cycle. We have proposed that "tonic" pericolumnar expiratory (t-E) neurons tune breathing during baroreceptor-evoked reductions and central chemoreceptor-evoked enhancements of inspiratory (I) drive. The aims of this study were to further characterize the coordinated activity of t-E neurons and test the hypothesis that peripheral chemoreceptors also modulate drive via inhibition of t-E neurons and disinhibition of their inspiratory neuron targets. Spike trains of 828 VRC neurons were acquired by multielectrode arrays along with phrenic nerve signals from 22 decerebrate, vagotomized, neuromuscularly blocked, artificially ventilated adult cats. Forty-eight of 191 t-E neurons fired synchronously with another t-E neuron as indicated by cross-correlogram central peaks; 32 of the 39 synchronous pairs were elements of groups with mutual pairwise correlations. Gravitational clustering identified fluctuations in t-E neuron synchrony. A network model supported the prediction that inhibitory populations with spike synchrony reduce target neuron firing probabilities, resulting in offset or central correlogram troughs. In five animals, stimulation of carotid chemoreceptors evoked changes in the firing rates of 179 of 240 neurons. Thirty-two neuron pairs had correlogram troughs consistent with convergent and divergent t-E inhibition of I cells and disinhibitory enhancement of drive. Four of 10 t-E neurons that responded to sequential stimulation of peripheral and central chemoreceptors triggered 25 cross-correlograms with offset features. The results support the hypothesis that multiple afferent systems dynamically tune inspiratory drive in part via coordinated t-E neurons. Copyright © 2015 the American Physiological Society.

  14. Can bronchodilators improve exercise tolerance in COPD patients without dynamic hyperinflation?

    Directory of Open Access Journals (Sweden)

    Maria Enedina Aquino Scuarcialupi

    2014-04-01

    Full Text Available OBJECTIVE: To investigate the modulatory effects that dynamic hyperinflation (DH, defined as a reduction in inspiratory capacity (IC, has on exercise tolerance after bronchodilator in patients with COPD. METHODS: An experimental, randomized study involving 30 COPD patients without severe hypoxemia. At baseline, the patients underwent clinical assessment, spirometry, and incremental cardiopulmonary exercise testing (CPET. On two subsequent visits, the patients were randomized to receive a combination of inhaled fenoterol/ipratropium or placebo. All patients then underwent spirometry and submaximal CPET at constant speed up to the limit of tolerance (Tlim. The patients who showed ΔIC(peak-rest 0.05. In addition, both groups showed similar improvements in Tlim after bronchodilator (median [interquartile range]: 22% [3-60%] vs. 10% [3-53%]; p > 0.05. CONCLUSIONS: Improvement in TLim was associated with an increase in IC at rest after bronchodilator in HD- patients with COPD. However, even without that improvement, COPD patients can present with greater exercise tolerance after bronchodilator provided that they develop DH during exercise.

  15. PDC IC WELD FAILURE EVALUATION AND RESOLUTION

    Energy Technology Data Exchange (ETDEWEB)

    Korinko, P.; Howard, S.; Maxwell, D.; Fiscus, J.

    2012-04-16

    improvements for the actual can welding process, however, did not result in an improved weld geometry. Several possibilities for the lack of positive response exist, some of which are that (1) an insufficient number of test articles were welded under prototypic conditions, (2) the process was not optimized so that significant improvements were observable over the 'noise', and (3) the in-situ arc anneal closed the gap down too much so the can was unable to exhaust pressure ahead of the weld. Several operational and mechanical improvements were identified. The weld clamps were changed to a design consistent with those used in the legacy operations. A helium puff operation was eliminated; it is believed that this operation was the cause of the original weld defect. Also, timing of plug mast movement was found to correspond with weld irregularities. The timing of the movement was changed to occur during weld head travel between tacks. In the end a three sequential tack weld process followed by a pulse weld at the same current and travel speed as was used for the legacy processes was suggested for use during the IC qualification effort. Relative to legacy welds, the PDC IC weld demonstrates greater fluctuation in the region of the weld located between tack welds. However, canister weld response (canister to canister) is consistent and with the aid of the optical mapping system (for targeting the cut position) is considered adequate. DR measurements and METs show the PDC IC welds to have sufficient ligament length to ensure adequate canister pressure/impact capacity and to ensure adequate stub function. The PDC welding process has not been optimized as a result of this effort. Differences remain between the legacy BTC welds and the PDC IC weld, but these differences are not sufficient to prevent resumption of the current PDC IC qualification effort. During the PDC IC qualification effort, a total of 17 cans will be welded and a variety of tests/inspections will be

  16. Dynamical Competition of IC-Industry Clustering from Taiwan to China

    Science.gov (United States)

    Tsai, Bi-Huei; Tsai, Kuo-Hui

    2009-08-01

    Most studies employ qualitative approach to explore the industrial clusters; however, few research has objectively quantified the evolutions of industry clustering. The purpose of this paper is to quantitatively analyze clustering among IC design, IC manufacturing as well as IC packaging and testing industries by using the foreign direct investment (FDI) data. The Lotka-Volterra system equations are first adopted here to capture the competition or cooperation among such three industries, thus explaining their clustering inclinations. The results indicate that the evolution of FDI into China for IC design industry significantly inspire the subsequent FDI of IC manufacturing as well as IC packaging and testing industries. Since IC design industry lie in the upstream stage of IC production, the middle-stream IC manufacturing and downstream IC packing and testing enterprises tend to cluster together with IC design firms, in order to sustain a steady business. Finally, Taiwan IC industry's FDI amount into China is predicted to cumulatively increase, which supports the industrial clustering tendency for Taiwan IC industry. Particularly, the FDI prediction of Lotka-Volterra model performs superior to that of the conventional Bass model after the forecast accuracy of these two models are compared. The prediction ability is dramatically improved as the industrial mutualism among each IC production stage is taken into account.

  17. Effects of body temperature, passive limb motion and level of anesthesia on the activity of the inspiratory muscles.

    Science.gov (United States)

    D'Angelo, E

    1984-04-01

    The relationships between relative tidal activity (moving average EMG) of the diaphragm (AdiT) and of the external intercostal or parasternal muscles (AicT) and between the rate of rise of these activities (Adi and Aic) were assessed during rebreathing in rabbits with various body temperatures (BT: 34-41 degrees C) before and after vagotomy (VGT), at rest and during passive limb motion (PLM), and in vagotomized rabbits with or without thoracic dorsal rhizotomy (TDR) under light (LBA) or deep barbiturate anesthesia (DBA). Both relationships had the form AicT = a AdiTb and Aic = a' Adib'. In intact normothermic animals under LBA mean values for b and b' were 1.47 and 1.37, a and a' being unity by definition. No changes in b or b' occurred even with TDR: this suggests that the relation between the central command to phrenic and to inspiratory intercostal alpha-motoneurones was the same under all conditions. Neither BT nor PLM modified a', but a changed owing to BT and PLM dependence of the relation between central inspiratory drive and off-switch threshold. Both VGT, independently of BT, and DBA decreased a and a' before but not after TDR, when a and a' reached the lowest values (0.12 and 0.22). Hence VGT and DBA, but not BT and PLM, change the relation between the central command to inspiratory intercostal alpha- and gamma-motoneurones, the multiplicative effect of alpha-gamma linkage on AicT and Aic being prevented by TDR.

  18. IC Associated Conditions

    Science.gov (United States)

    ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Newly Diagnosed Toolkit IC Awareness Toolkit Know ... Bowel Syndrome Lupus Pelvic Floor Dysfunction Pudendal Neuralgia Sjogren’s Syndrome Vulvodynia Click to learn more about these and ...

  19. Physical exercise modifies the functional capacity of elderly patients on hemodialysis

    Directory of Open Access Journals (Sweden)

    Moane Marchesan

    Full Text Available Abstract Introduction Patients on hemodialysis (HD improve functional capacity after physical training. However, little is discussed about these effects in elderly patients, since these are usually excluded of studies, due to their physical disabilities and other deficits. Objective To analyze the effects of aerobic and resistance training in the functional capacity of elderly patients submitted to HD. Methods Studied participants were 15 patients, of both genders, and aged over 60 years. Aerobic and resistance training was carried out during the hemodialysis session, three times per week, during four months. Patients were distributed into control (CG and experimental (EG groups. Functional capacity was assessed by six-minute walk (6MW, sit-to-stand (STS and respiratory muscle strength tests. Results After the physical training, EG presented a significant increase in the distance covered in 6MW (Z = 2.521, p < .012, respiratory muscle strength (inspiratory pressure: Z = 2.533, p < .011; expiratory pressure: Z = 2.536, p < .011; and in number of STS repetitions (2.54; p <.001. Conclusion The training modified the functional capacity of the HD patients, contributing to their rehabilitation.

  20. The role of arterial chemoreceptors in the breath-by-breath augmentation of inspiratory effort in rabbits during airway occlusion or elastic loading.

    Science.gov (United States)

    Callanan, D; Read, D J

    1974-08-01

    1. The breath-by-breath augmentation of inspiratory effort in the five breaths following airway occlusion or elastic loading was assessed in anaesthetized rabbits from changes of airway pressure, diaphragm e.m.g. and lung volume.2. When the airway was occluded in animals breathing air, arterial O(2) tension fell by 20 mmHg and CO(2) tension rose by 7 mmHg within the time of the first five loaded breaths.3. Inhalation of 100% O(2) or carotid denervation markedly reduced the breath-by-breath progression but had little or no effect on the responses at the first loaded breath.4. These results indicate that the breath-by-breath augmentation of inspiratory effort following addition of a load is mainly due to asphyxial stimulation of the carotid bodies, rather than to the gradual emergence of a powerful load-compensating reflex originating in the chest-wall, as postulated by some workers.5. The small residual progression seen in animals breathing 100% O(2) or following carotid denervation was not eliminated (a) by combining these procedures or (b) by addition of gas to the lungs to prevent the progressive lung deflation which occurred during airway occlusion.6. Bilateral vagotomy, when combined with carotid denervation, abolished the residual breath-by-breath progression of inspiratory effort.

  1. Effects of inspiratory muscle training on respiratory function and repetitive sprint performance in wheelchair basketball players.

    Science.gov (United States)

    Goosey-Tolfrey, V; Foden, E; Perret, C; Degens, H

    2010-07-01

    There is considerable evidence that respiratory muscle training improves pulmonary function, quality of life and exercise performance in healthy athletic populations. The benefits for wheelchair athletes are less well understood. Therefore, in the present study, influence of inspiratory muscle training (IMT) on respiratory function and repetitive propulsive sprint performance in wheelchair basketball players was examined. Using a placebo-controlled design, 16 wheelchair athletes were divided to an experimental (IMT; n=8) or placebo (sham-IMT; n=8) group based on selective grouping criteria. 30 dynamic breaths were performed by the IMT group twice daily at a resistance equivalent to 50% maximum inspiratory pressure (MIP), and 60 slow breaths were performed by the sham-IMT group once a day at 15% MIP for a period of 6 weeks. In the IMT group, both MIP and maximum expiratory pressure (17% and 23%, respectively; ptraining device suggested "less breathlessness" and "less tightness in the chest during the training". Although there was no improvement in sprint performance, an improved respiratory muscle function and quality of life were reported by participants in both the IMT and sham-IMT groups.

  2. Influence of heart failure on resting lung volumes in patients with COPD.

    Science.gov (United States)

    Souza, Aline Soares de; Sperandio, Priscila Abreu; Mazzuco, Adriana; Alencar, Maria Clara; Arbex, Flávio Ferlin; Oliveira, Mayron Faria de; O'Donnell, Denis Eunan; Neder, José Alberto

    2016-01-01

    To evaluate the influence of chronic heart failure (CHF) on resting lung volumes in patients with COPD, i.e., inspiratory fraction-inspiratory capacity (IC)/TLC-and relative inspiratory reserve-[1 - (end-inspiratory lung volume/TLC)]. This was a prospective study involving 56 patients with COPD-24 (23 males/1 female) with COPD+CHF and 32 (28 males/4 females) with COPD only-who, after careful clinical stabilization, underwent spirometry (with forced and slow maneuvers) and whole-body plethysmography. Although FEV1, as well as the FEV1/FVC and FEV1/slow vital capacity ratios, were higher in the COPD+CHF group than in the COPD group, all major "static" volumes-RV, functional residual capacity (FRC), and TLC-were lower in the former group (p grupo DPOC+ICC; 23 homens/1 mulher) e 32 (28 homens/4 mulheres) com DPOC isolada foram submetidos à espirometria forçada e lenta e pletismografia de corpo inteiro. Os pacientes do grupo DPOC+ICC apresentaram maior VEF1, VEF1/CVF e VEF1/capacidade vital lenta; porém, todos os principais volumes "estáticos" - VR, capacidade residual funcional (CRF) e CPT - foram menores que aqueles do grupo DPOC (p grupo DPOC+ICC que no grupo DPOC. Houve redução relativamente proporcional da CRF e da CPT nos dois grupos; logo, a CI também foi similar. Consequentemente, a fração inspiratória no grupo DPOC+ICC foi maior que no grupo DPOC (0,42 ± 0,10 vs. 0,36 ± 0,10; p grupo DPOC+ICC, a reserva inspiratória relativa foi notadamente similar entre os grupos (0,35 ± 0,09 vs. 0,44 ± 0,14; p < 0,05). Apesar dos efeitos restritivos da ICC, pacientes com DPOC+ICC apresentam elevações relativas dos limites inspiratórios (maior fração inspiratória). Entretanto, esses pacientes utilizam apenas parte desses limites, com o provável intuito de evitar reduções críticas da reserva inspiratória e maior trabalho elástico.

  3. Conceptualising Intellectual Capital (IC) as Language Game and Power

    DEFF Research Database (Denmark)

    Jørgensen, Kenneth Mølbjerg

    2006-01-01

    Intellectual Capital (IC) can be viewed as knowledge about knowledge, knowledge creation and how such processes might be leveraged into value. Developing a critical understanding of IC requires a historical and contextual understanding of how IC has emerged and how IC is used. This paper, drawing...... this process of social construction. The paper concludes by proposing some methodological guidelines for conducting critical genealogical research on intellectual capital....

  4. Effects of walking and strength training on walking capacity in individuals with claudication: meta-analysis

    Directory of Open Access Journals (Sweden)

    Alessandra de Souza Miranda

    2013-06-01

    Full Text Available CONTEXT: Over the past few years, several clinical trials have been performed to analyze the effects of exercise training on walking ability in patients with intermittent claudication (IC. However, it remains unclear which type of physical exercise provides the maximum benefits in terms of walking ability. OBJECTIVE: To analyze, by means of a meta-analysis, the effects of walking and strength training on the walking capacity in patients with IC. METHODS: Papers analyzing the effects of walking and strength training programs in patients with IC were browsed on the Medline, Lilacs, and Cochrane databases. Randomized clinical trials scoring >4 on the Physiotherapy Evidence Database (PEDro scale and assessing claudication distance (CD and total walking distance (TWD were included in the review. RESULTS: Walking and strength training yielded increases in CD and TWD (P < 0.05. However, walking training yielded greater increases than strength training (P = 0.02. CONCLUSION: Walking and strength training improve walking capacity in patients with IC. However, greater improvements in TWD are obtained with walking training.

  5. Correlations between respiratory and functional variables in heart failure

    Directory of Open Access Journals (Sweden)

    Fábio Cangeri Di Naso

    2009-09-01

    Full Text Available Background: Respiratory alterations can impact on the functional performance of patients with heart failure. Aim: To correlate maximum inspiratory muscular force and lung function variables with functional capacity in heart failure patients. Methods: A transversal study January-July 2007 with 42 chronic heart disease patients (28 males with no prior pulmonary illness. The patients were in New York Heart Association Functional Class I, II and III. The variables used were maximum inspiratory pressure, forced vital capacity and forced expiratory volume in the first second. Respiratory variables measured were distance covered in the six-minute walk test, NYHA functional class and the physical functioning domain of the Short Form-36 Quality of Life Questionnaire. Results: Maximum inspiratory pressure correlated with the six-minute walk test (r = 0.543 and p < 0.001, functional capacity (r = −0.566 and p < 0.001 and the physical functioning domain score of the Short Form-36 (r = 0.459 and p = 0.002. The same was true of forced vital capacity and the six-minute walk test (r = 0.501 and p = 0.001, functional capacity (r = −0.477 and p = 0.001 and Short Form-36 (r = 0.314 and p = 0.043 variables. Forced expiratory volume correlated with the distance covered in the six-minute walk test (r = 0.514 and p < 0.001 and functional capacity (r = −0.383 and p = 0.012. Conclusion: Lung function and inspiratory muscular force respiratory variables correlated with functional variables in patients with heart failure. Resumo: Fundamento: Alterações respiratórias podem influenciar o desempenho funcional em doentes com insuficiência cardíaca (IC. Objectivo: Correlacionar a força muscular inspiratória máxima (PImax e as variáveis da função pulmonar com a capacidade funcional em doentes com IC. Métodos: Estudo transversal

  6. Extracción de cobre desde soluciones clorhídricas con LIX 860N-IC y LIX 84-IC

    Directory of Open Access Journals (Sweden)

    Navarro, Carlos María

    2001-08-01

    Full Text Available In this work, the extraction of copper from chloride solutions with two hydroxyoximes: 5- nonylsalicylaldoxime (LIX 860N-IC and 2-hydroxy-5-nonylacetophenona oxime (LIX 84-IC is discussed. The results showed that an increase in the acidity and an increase in the total concentration of chloride ions in the aqueous phase decreased significantly the extraction of copper as well as the extraction of iron for both extractants. This effect of the chloride ions can be explained by the formation of a series of chloro complexes of Cu(II and Fe(III in the aqueous phase. The effect of initial pH and total chloride concentration on the extraction of chloride by the organic phase suggests that LIX 860N-IC, and to a lesser extent LIX 84-IC, extract small amounts of the cationic complex, CuCl+. An increase in the concentration of chloride ions also produced a small decrease in the rate of copper extraction with both hydroxyoximes.

    En este trabajo se discute el estudio de la extracción de cobre desde soluciones clorhídricas con dos hidroxioximas: 5-nonilsalicilaldoxima (LIX 860N-IC, y 2-hidroxi-5 nonilacetofenona oxima (LIX 84-IC. Los resultados indicaron que al aumentar la acidez o aumentar la concentración de cloruro en la fase acuosa se produce una significativa disminución en la extracción de cobre y hierro con ambas hidroxioximas. Este efecto del ion cloruro se explica por la formación de varios clorocomplejos de Cu(II y Fe(III en la solución acuosa. El efecto del pH y la concentración total de cloruro en la extracción de cloruro sugiere que el LIX 860N-IC, y en menor grado el LIX 84-IC extraen pequeñas cantidades del catión monovalente, CuCl+. Se determinó también que un aumento en la concentración de cloruro en la solución acuosa produce una leve disminución en la velocidad de extracción del cobre con ambas hidroxioximas.

  7. Inspiratory Muscle Training and Functional Electrical Stimulation for Treatment of Heart Failure With Preserved Ejection Fraction: The TRAINING-HF Trial.

    Science.gov (United States)

    Palau, Patricia; Domínguez, Eloy; López, Laura; Ramón, José María; Heredia, Raquel; González, Jessika; Santas, Enrique; Bodí, Vicent; Miñana, Gema; Valero, Ernesto; Mollar, Anna; Bertomeu González, Vicente; Chorro, Francisco J; Sanchis, Juan; Lupón, Josep; Bayés-Genís, Antoni; Núñez, Julio

    2018-03-16

    Despite the prevalence of heart failure with preserved ejection fraction (HFpEF), there is currently no evidence-based effective therapy for this disease. This study sought to evaluate whether inspiratory muscle training (IMT), functional electrical stimulation (FES), or a combination of both (IMT + FES) improves 12- and 24-week exercise capacity as well as left ventricular diastolic function, biomarker profile, and quality of life in HFpEF. A total of 61 stable symptomatic patients (New York Heart Association II-III) with HFpEF were randomized (1:1:1:1) to receive a 12-week program of IMT, FES, or IMT + FES vs usual care. The primary endpoint of the study was to evaluate change in peak exercise oxygen uptake at 12 and 24 weeks. Secondary endpoints were changes in quality of life, echocardiogram parameters, and prognostic biomarkers. We used a mixed-effects model for repeated-measures to compare endpoints changes. Mean age and peak exercise oxygen uptake were 74 ± 9 years and 9.9 ± 2.5mL/min/kg, respectively. The proportion of women was 58%. At 12 weeks, the mean increase in peak exercise oxygen uptake (mL/kg/min) compared with usual care was 2.98, 2.93, and 2.47 for IMT, FES, and IMT + FES, respectively (P < .001) and this beneficial effect persisted after 6 months (1.95, 2.08, and 1.56; P < .001). Significant increases in quality of life scores were found at 12 weeks (P < .001). No other changes were found. In HFpEF patients with low aerobic capacity, IMT and FES were associated with a significant improvement in exercise capacity and quality of life. This trial was registered at ClinicalTrials.gov (Identifier: NCT02638961).. Copyright © 2018 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  8. Measuring IC following a semi-qualitative approach: An integrated framework

    Directory of Open Access Journals (Sweden)

    Chiara Verbano

    2013-09-01

    Full Text Available Purpose: Considering the different IC measures adopted in literature, the advantages of adopting semi-qualitative measures, and the lack of an agreed system for IC evaluation, the purpose of the paper is to analyse literature on IC measurement following a semi-qualitative approach, with the final intent to build an IC measurement framework. Design/methodology/approach: A literature review on IC measurement system, following a semi-qualitative approach, has been conducted and analysed, in order to re-organize and synthesize all items used in previous researches. Findings: An integrated framework emerged from this research and it constitutes an IC  measurement system, created gathering and integrating different items previously adopted in literature. Each of these variables has been organized in categories belonging to one of the three main components of IC: human capital, internal structural capital and relational capital. Originality/value: This research provides an integrated tool for IC evaluation, fostering toward a well agreed measurement system that is still lacking in literature. This framework could be interesting  not only for the academic world, which in the last two decades reveals increasing attention to IC, but also for the management of the companies, that with IC measurement can increase awareness of the firm’s value and develop internal auditing system to support the management of these assets. Moreover, it could be a useful instrument for the communication of IC value to the external stakeholders, as customers, suppliers and especially shareholders, and to investors and financial analysts.

  9. Effects of thoracic dorsal rhizotomy or vagotomy on inspiratory muscle activity at various levels of chemical drive.

    Science.gov (United States)

    D'Angelo, E; Schieppati, M

    1982-11-01

    The relationship between relative peak activity (moving average EMG) of the diaphragm (Adi) and of the cranial (2nd and 3rd) external intercostal or parasternal muscles (Aic) was assessed during rebreathing in animals before and after bilateral thoracic (T1-T4) dorsal rhizotomy (TDR) and/or bilateral vagotomy (VGT). The relationship had the form Aic=a Adib under all conditions. In intact rabbits and cats mean values for b were 1.48 and 1.79, respectively, a being unity by definition. Neither TDR nor VGT changed b; a decreased to about 0.15 with TDR and halved with VGT only if performed before TDR. Selective reflex facilitation of inspiratory intercostals with occlusions at FRC was observed after VGT and was abolished by TDR. Neither VGT nor TDR affected Adi time course. Hence: (1) central command to alpha-motoneurones of the major inspiratory muscles differs; (2) proprioceptive feedback markedly increases external intercostal activity, apparently by multiplying Aic due to central command to alpha-motoneurones by a factor independent of chemical drive; (3) vagally mediated augmentation of Aic depends entirely on intact proprioceptive feedback. The possible role of fusimotor drive is discussed.

  10. Lung function study and diffusion capacity in anorexia nervosa.

    Science.gov (United States)

    Pieters, T; Boland, B; Beguin, C; Veriter, C; Stanescu, D; Frans, A; Lambert, M

    2000-08-01

    In humans, malnutrition alters the respiratory system in different ways. It impairs the ventilatory drive, decreases respiratory muscle strength and reduces immune competence. In addition, typical emphysema-like changes were demonstrated in starved animals. The presence of emphysema has never been demonstrated in starved humans. Our objective was to investigate whether pulmonary emphysema occurs in anorexia nervosa by means of a pulmonary function study. We examined 24 women aged between 14 and 38 years (nine smokers). We studied the lung function including lung volumes, ventilatory capacity, maximal respiratory pressures and transfer factor, as well as PaO2. All respiratory tests were within normal limits with the exception of decreased maximal inspiratory (59% of predicted values) and expiratory pressures (35%), and increased residual volume (162%). Diffusion capacity (98.1 +/- 16.2%) and transfer coefficient (98.4 +/- 16.2%) were also normal. The diffusion coefficient was lower in current smokers than in those who had never smoked (P anorexia nervosa, pulmonary function tests are within normal limits with the exception of maximal pressures and residual volume. Diffusion capacity is not decreased. The present results within the limitations of the used method are not compatible with the hypothesis of starvation-induced pulmonary emphysema.

  11. Transferring the Incremental Capacity Analysis to Lithium-Sulfur Batteries

    DEFF Research Database (Denmark)

    Knap, Vaclav; Kalogiannis, Theodoros; Purkayastha, Rajlakshmi

    2017-01-01

    In order to investigate the battery degradation and to estimate their health, various techniques can be applied. One of them, which is widely used for Lithium-ion batteries, is the incremental capacity analysis (ICA). In this work, we apply the ICA to Lithium-Sulfur batteries, which differ in many...... aspects from Lithium-ion batteries and possess unique behavior. One of the challenges of applying the ICA to Lithium-Sulfur batteries is the representation of the IC curves, as their voltage profiles are often non-monotonic, resulting in more complex IC curves. The ICA is at first applied to charge...

  12. HI observations of the irregular galaxy IC 10

    International Nuclear Information System (INIS)

    Shostak, G.S.; Woerden, H. van

    1983-01-01

    The authors have made radio synthesis observations of the galaxy IC 10 with resolutions of 30 arcsec and 8 km/sec in the neutral hydrogen line using the Westerbork telescope. These confirm Shostak's (1974) result that, in the central region of IC 10, the velocity gradient is opposite to that later measured by single-dish in the outer regions. The suggestion by Cohen (1979) that the velocity gradient reversal is due to IC 10 being nearly face-on and warped is consistent with the new data. (Auth.)

  13. Maintained inspiratory activity during proportional assist ventilation in surfactant-depleted cats early after surfactant instillation: phrenic nerve and pulmonary stretch receptor activity

    Directory of Open Access Journals (Sweden)

    Schaller Peter

    2006-03-01

    Full Text Available Abstract Background Inspiratory activity is a prerequisite for successful application of patient triggered ventilation such as proportional assist ventilation (PAV. It has recently been reported that surfactant instillation increases the activity of slowly adapting pulmonary stretch receptors (PSRs followed by a shorter inspiratory time (Sindelar et al, J Appl Physiol, 2005 [Epub ahead of print]. Changes in lung mechanics, as observed in preterm infants with respiratory distress syndrome and after surfactant treatment, might therefore influence the inspiratory activity when applying PAV early after surfactant treatment. Objective To investigate the regulation of breathing and ventilatory response in surfactant-depleted young cats during PAV and during continuous positive airway pressure (CPAP early after surfactant instillation in relation to phrenic nerve activity (PNA and the activity of PSRs. Methods Seven anesthetized, endotracheally intubated young cats were exposed to periods of CPAP and PAV with the same end-expiratory pressure (0.2–0.5 kPa before and after lung lavage and after surfactant instillation. PAV was set to compensate for 75% of the lung elastic recoil. Results Tidal volume and respiratory rate were higher with lower PaCO2 and higher PaO2 during PAV than during CPAP both before and after surfactant instillation (p Conclusion PSR activity and the control of breathing are maintained during PAV in surfactant-depleted cats early after surfactant instillation, with a higher ventilatory response and a lower breathing effort than during CPAP.

  14. Bio-medical CMOS ICs

    CERN Document Server

    Yoo, Hoi-Jun

    2011-01-01

    This book is based on a graduate course entitled, Ubiquitous Healthcare Circuits and Systems, that was given by one of the editors. It includes an introduction and overview to biomedical ICs and provides information on the current trends in research.

  15. K/sub Ic/ and J/sub Ic/ of Westerly granite: effects of thickness and in-plane dimensions

    International Nuclear Information System (INIS)

    Schmidt, R.A.; Lutz, T.J.

    1978-01-01

    An investigation is described in which tensile properties, fracture toughness, and critical J integral are measured for Westerly granite, a rock that is widely used in rock mechanics studies. This was primarily a parameter sensitivity study in which the effects of specimen dimensions and testing techniques were assessed. It is hoped that this study will aid in establishing tentative standards and guidelines for fracture toughness testing of rock as well as indicate the feasibility of using a J integral fracture criterion for this material. ASTM standard specimen configurations of the compact and bend types were tested with compact specimens ranging in width from W = 25.4 mm to W = 406.4 mm (0.5T to 8T) and with thickness ranging from 13 mm to 100 mm. A series of 4T compact specimens were tested to assess the effects of thickness and fatigue precracking. Techniques are described that enable several values of K/sub Ic/, a complete J vs crack growth curve, and a J/sub Ic/ value to be obtained from each sample. Direct-pull tension tests on shaped specimens of Westerly granite are described which indicate a high degree of nonlinear, inelastic behavior. This fact raises questions about the use of LEFM, but the J/sub Ic/ data presented appear to validate the K/sub Ic/ measurements

  16. Differential effectiveness of Serratia plymuthica IC1270-induced systemic resistance against hemibiotrophic and necrotrophic leaf pathogens in rice

    Directory of Open Access Journals (Sweden)

    Höfte Monica M

    2009-01-01

    Full Text Available Abstract Background Induced resistance is a state of enhanced defensive capacity developed by a plant reacting to specific biotic or chemical stimuli. Over the years, several forms of induced resistance have been characterized, including systemic acquired resistance, which is induced upon localized infection by an avirulent necrotizing pathogen, and induced systemic resistance (ISR, which is elicited by selected strains of nonpathogenic rhizobacteria. However, contrary to the relative wealth of information on inducible defense responses in dicotyledoneous plants, our understanding of the molecular mechanisms underlying induced resistance phenomena in cereal crops is still in its infancy. Using a combined cytomolecular and pharmacological approach, we analyzed the host defense mechanisms associated with the establishment of ISR in rice by the rhizobacterium Serratia plymuthica IC1270. Results In a standardized soil-based assay, root treatment with IC1270 rendered foliar tissues more resistant to the hemibiotrophic pathogen Magnaporthe oryzae, causal agent of the devastating rice blast disease. Analysis of the cytological and biochemical alterations associated with restriction of fungal growth in IC1270-induced plants revealed that IC1270 primes rice for enhanced attacker-induced accumulation of reactive oxygen species (ROS and autofluorescent phenolic compounds in and near epidermal cells displaying dense cytoplasmic granulation. Similar, yet more abundant, phenotypes of hypersensitively dying cells in the vicinity of fungal hyphae were evident in a gene-for-gene interaction with an avirulent M. oryzae strain, suggesting that IC1270-inducible ISR and R protein conditioned effector-triggered immunity (ETI target similar defense mechanisms. Yet, this IC1270-inducible ISR response seems to act as a double-edged sword within the rice defense network as induced plants displayed an increased vulnerability to the necrotrophic pathogens Rhizoctonia

  17. Current status of ITER I&C system as integration begins

    Energy Technology Data Exchange (ETDEWEB)

    Davis, William, E-mail: william.davis@iter.org [ITER Organisation, Route de Vinon-sur Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Wallander, Anders [ITER Organisation, Route de Vinon-sur Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Yonekawa, Izuru [Nippon Advanced Technology Ltd., 3129-45 Hibara Muramatsu, Tokai, Naka-gun, Ibaraki 319-1112 (Japan)

    2016-11-15

    Highlights: • The ITER I&C system is organisationally complicated and technically challenging. • Standard technologies for the ITER I&C systems have been selected. • Supply of non-standard technologies will cause serious issues. • Differing levels of design maturity of plant I&C systems is a serious challenge. • Systems are in the final stages of design and are being delivered to site. - Abstract: The ITER I&C system is organisationally complicated and technically challenging, and integrating its many sub-systems into a single coherent system is critical for the ITER project to meet its objectives. This paper explains the integration risks being faced now and anticipated in the near future. Standardisation initiatives by the ITER central team to mitigate these risks are described. The paper also presents the architecture of the ITER I&C system, the current status of design and manufacture key developments made in recent years, and the current and future activities of the central I&C teams. Finally, a short description is given of the plant I&C systems that will be delivered to ITER in the near future.

  18. El contenido de los mensajes icónicos: El discurso icónico como totalidad (2)

    OpenAIRE

    Dr. Raymond Colle

    1999-01-01

    En el capítulo anterior, hemos hablado de los códigos icónicos de modo general, por cuanto tienen algunas características comunes, en particular el uso de figuras como factores de los significantes. Sin embargo, como lo hemos señalado al final, no todos se construyen ni articulan de la misma manera. Tal como las lenguas son muchas y los códigos lingüísticos se rigen por diferentes reglas -aunque sobre la base de fonemas unidos secuencialmente-, los códigos icónicos son también variados y regi...

  19. Studies on the pathogenesis of Aleutian disease of mink. X. demonstration of immune complexes by the /sup 125/I-C 1 q binding test after experimental infection

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Peddinghaus, R [Kali-Chemie Pharma G.m.b.H., Hannover (Germany, F.R.). Abt. fuer Experimentelle Pathologie; Meyer zu Schwabedissen, H [Medizinische Hochschule Hannover (Germany, F.R.). Abt. fuer Klinische Immunologie und Bluttransfusionswesen; Kalden, J R [Erlangen-Nuernberg Univ., Erlangen (Germany, F.R.). Inst. und Poliklinik fuer Klinische Immunologie; Trautwein, G; Ueberschaer, S [Tieraerztliche Hochschule Hannover (Germany, F.R.). Inst. fuer Pathologie

    1980-01-01

    Aleutian disease (AD) of mink most closely resembles systemic lupus erythematosus (SLE) in man; both are immune complex disease. In experimental AD serum immune complexes are determined by the /sup 125/J-C 1 q-binding test using human C 1 q. Mink (n = 12) infected intraperitoneally with Aleutian disease virus (ADV), grown in fetal mink kidney cells, developed during the course of infection a mean of /sup 125/I-C 1 q serum binding equivalent to 3.62 +- 1.68 mg./ml. aggr. HGG. (aggregated human immunoglobulin). Sera of mink (n = 8) which were infected with ADV grown in L-cells showed a less marked /sup 125/I-C 1 q binding with a mean equivalent to 2.52 +- 1.43 mg./ml. aggr. HGG. In contrast control animals (n = 8) treated with non-ADV-infected mink epidermal fibroblasts or Eagle's minimal essential medium substituted with fetal calf serum only bound /sup 125/I-C 1 q equivalent to 1.02 +- 0.99 mg./ml. aggr. HGG. In mink infected with ADV propagated in fetal mink kidney cells a constant increase in the /sup 125/I-C 1 q serum binding occurred from the 4th to the 7th and 13th week after ADV infection. Mink which were infected with ADV propagated in mouse L-cells exhibited a different pattern of the /sup 125/I-C 1 q serum binding capacity with a sharp increase from the 4th to the 7th week, followed by a decline towards the 13th week post infection. The serum /sup 125/I-C 1 q binding capacity of all experimental animal groups exhibited at different times of the experiment a significant correlation with the presence of hypergammaglobulinaemia and raised ADV-antibody titers. From the data obtained it appears that the /sup 125/I-C 1 q binding test, utilizing human C 1 q, is a suitable method for the detection of circulating serum immune complexes in mink during the course of ADV-infection.

  20. Ultrasonographic assessment of the diaphragm in chronic obstructive pulmonary disease patients: relationships with pulmonary function and the influence of body composition - a pilot study.

    Science.gov (United States)

    Smargiassi, Andrea; Inchingolo, Riccardo; Tagliaboschi, Linda; Di Marco Berardino, Alessandro; Valente, Salvatore; Corbo, Giuseppe Maria

    2014-01-01

    Skeletal muscle weakness with loss of fat-free mass (FFM) is one of the main systemic effects of chronic obstructive pulmonary disease (COPD). The diaphragm is also involved, leading to disadvantageous conditions and poor contractile capacities. We measured the thickness of the diaphragm (TD) by ultrasonography to evaluate the relationships between echographic measurements, parameters of respiratory function and body composition data. Thirty-two patients (23 males) underwent (1) pulmonary function tests, (2) echographic assessment of TD in the zone of apposition at various lung volumes, i.e. TD at residual volume (TDRV), TD at functional residual capacity (TDFRC) and TD at total lung capacity (TDTLC), and (3) bioelectrical body impedance analysis. The BMI and the BODE (BMI-Obstruction-Dyspnea-Exercise) index values were reported. TDRV, TDFRC and TDTLC measured 3.3, 3.6 and 6 mm, respectively, with good intraobserver reproducibility (0.97, 0.97 and 0.96, respectively). All the TDs were found to be related to FFM, with the relationship being greater for TDFRC (r(2) = 0.39 and p = 0.0002). With regard to lung volumes, inspiratory capacity (IC) was found to be closely related to TDTLC (r(2) = 0.42 and p = 0.0001). The difference between TDTLC and TDRV, as a thickening value (TDTLCRV), was closely related to FVC (r(2) = 0.34 and p = 0.0004) and to air-trapping indices (RV/TLC, FRC/TLC and IC/TLC): the degree of lung hyperinflation was greater and the TDTLCRV was less. Finally, we found a progressive reduction of both thicknesses and thickenings as the severity of IC/TLC increased, with a significant p value for the trend in both analyses (p = 0.02). Ultrasonographic assessment of the diaphragm could be a useful tool for studying disease progression in COPD patients, in terms of lung hyperinflation and the loss of FFM. © 2014 S. Karger AG, Basel.

  1. Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway.

    Directory of Open Access Journals (Sweden)

    Samantha Torres Grams

    Full Text Available Maximal Inspiratory Pressure (MIP is considered an effective method to estimate strength of inspiratory muscles, but still leads to false positive diagnosis. Although MIP assessment with unidirectional expiratory valve method has been used in patients undergoing mechanical ventilation, no previous studies investigated the application of this method in subjects without artificial airway.This study aimed to compare the MIP values assessed by standard method (MIPsta and by unidirectional expiratory valve method (MIPuni in subjects with spontaneous breathing without artificial airway. MIPuni reproducibility was also evaluated.This was a crossover design study, and 31 subjects performed MIPsta and MIPuni in a random order. MIPsta measured MIP maintaining negative pressure for at least one second after forceful expiration. MIPuni evaluated MIP using a unidirectional expiratory valve attached to a face mask and was conducted by two evaluators (A and B at two moments (Tests 1 and 2 to determine interobserver and intraobserver reproducibility of MIP values. Intraclass correlation coefficient (ICC[2,1] was used to determine intraobserver and interobserver reproducibility.The mean values for MIPuni were 14.3% higher (-117.3 ± 24.8 cmH2O than the mean values for MIPsta (-102.5 ± 23.9 cmH2O (p<0.001. Interobserver reproducibility assessment showed very high correlation for Test 1 (ICC[2,1] = 0.91, and high correlation for Test 2 (ICC[2,1] = 0.88. The assessment of the intraobserver reproducibility showed high correlation for evaluator A (ICC[2,1] = 0.86 and evaluator B (ICC[2,1] = 0.77.MIPuni presented higher values when compared with MIPsta and proved to be reproducible in subjects with spontaneous breathing without artificial airway.

  2. Profiles of the N II 6584 A line over the giant H II regions IC 1318b and c, NGC 7000 and IC 5070. 2

    Energy Technology Data Exchange (ETDEWEB)

    Canto, J; Johnson, P G; Meaburn, J; Mikhail, J S; Terrett, D L; White, N J [Manchester Univ. (UK). Dept of Astronomy

    1979-06-01

    Previously (Paper I) large-scale splitting of the (N II) line was discovered over an area of IC 1318b. The motions of the ionized material have now been mapped over a much larger region of this nebula and also IC 1318c. The splitting reaches a maximum value of 53 km/s over the faintest regions of IC 1318b and occurs over an area approximately > 20 pc across. However, few split (N II) lines were found over IC 1318c, but the motions of this whole ionized and neutral complex have been shown to be closely related. Wind-driven flows along neutral and ionized shells are proposed to explain the observations. Similar measurements have also been made on either side of the dark lane separating NGC 7000 from IC 5070.

  3. Interband cascade (IC) photovoltaic (PV) architecture for PV devices

    Science.gov (United States)

    Yang, Rui Q.; Tian, Zhaobing; Mishima, Tetsuya D.; Santos, Michael B.; Johnson, Matthew B.; Klem, John F.

    2015-10-20

    A photovoltaic (PV) device, comprising a PV interband cascade (IC) stage, wherein the IC PV stage comprises an absorption region with a band gap, the absorption region configured to absorb photons, an intraband transport region configured to act as a hole barrier, and an interband tunneling region configured to act as an electron barrier. An IC PV architecture for a photovoltaic device, the IC PV architecture comprising an absorption region, an intraband transport region coupled to the absorption region, and an interband tunneling region coupled to the intraband transport region and to the adjacent absorption region, wherein the absorption region, the intraband transport region, and the interband tunneling region are positioned such that electrons will flow from the absorption region to the intraband transport region to the interband tunneling region.

  4. Time course and degree of hyperinflation with metronome-paced tachypnea in COPD patients.

    Science.gov (United States)

    Weigt, S Samuel; Abrazado, Marlon; Kleerup, Eric C; Tashkin, Donald P; Cooper, Christopher B

    2008-10-01

    In COPD patients, tachypnea should increase (dynamic) hyperinflation by shortening expiratory time. We developed a method to evaluate the time course and degree of dynamic hyperinflation during metronome-paced tachypnea. Fourteen patients with stable COPD (FEV(1) 43 +/- 13% predicted) were studied. Inspiratory capacity (IC) was measured breathing through a flow transducer. Subjects paced their respiratory rate (f(R)) at 20/min, 30/min and 40/min for 60-second periods in response to audible tones generated by a computer. IC measurements were obtained at baseline and after 30 and 60 seconds at each f(R). End-tidal carbon dioxide was monitored and f(R) was allowed to return to baseline between periods of tachypnea. Tachypnea produced reductions in IC of 200 +/- 240 ml, 380 +/- 330 ml and 540 +/- 300 ml after 30 seconds at 20/min, 30/min and 40/min, respectively. IC reduction at 60 seconds was similar to 30 seconds for each f(R). In patients with moderate-to-severe COPD, the dynamic hyperinflation induced by metronome-paced tachypnea was shown to occur rapidly and be complete by 30 seconds for a given f(R). Controlled increments in f(R) produced stepwise increases in dynamic hyperinflation. This standardized method could be a useful and easier method of assessing dynamic hyperinflation in COPD patients before and after therapeutic interventions.

  5. Theoretical study of inspiratory flow waveforms during mechanical ventilation on pulmonary blood flow and gas exchange.

    Science.gov (United States)

    Niranjan, S C; Bidani, A; Ghorbel, F; Zwischenberger, J B; Clark, J W

    1999-08-01

    A lumped two-compartment mathematical model of respiratory mechanics incorporating gas exchange and pulmonary circulation is utilized to analyze the effects of square, descending and ascending inspiratory flow waveforms during mechanical ventilation. The effects on alveolar volume variation, alveolar pressure, airway pressure, gas exchange rate, and expired gas species concentration are evaluated. Advantages in ventilation employing a certain inspiratory flow profile are offset by corresponding reduction in perfusion rates, leading to marginal effects on net gas exchange rates. The descending profile provides better CO2 exchange, whereas the ascending profile is more advantageous for O2 exchange. Regional disparities in airway/lung properties create maldistribution of ventilation and a concomitant inequality in regional alveolar gas composition and gas exchange rates. When minute ventilation is maintained constant, for identical time constant disparities, inequalities in compliance yield pronounced effects on net gas exchange rates at low frequencies, whereas the adverse effects of inequalities in resistance are more pronounced at higher frequencies. Reduction in expiratory air flow (via increased airway resistance) reduces the magnitude of upstroke slope of capnogram and oxigram time courses without significantly affecting end-tidal expired gas compositions, whereas alterations in mechanical factors that result in increased gas exchanges rates yield increases in CO2 and decreases in O2 end-tidal composition values. The model provides a template for assessing the dynamics of cardiopulmonary interactions during mechanical ventilation by combining concurrent descriptions of ventilation, capillary perfusion, and gas exchange. Copyright 1999 Academic Press.

  6. Neuromuscular electrical stimulation and inspiratory muscle training as potential adjunctive rehabilitation options for patients with heart failure.

    Science.gov (United States)

    Arena, Ross; Pinkstaff, Sherry; Wheeler, Emma; Peberdy, Mary Ann; Guazzi, Marco; Myers, Jonathan

    2010-01-01

    Aerobic and resistance exercise training programs produce an abundance of physiologic and clinical benefits in patients with heart failure (HF). Improved maximal aerobic capacity, submaximal aerobic endurance, muscle force production, perceived quality of life, and skeletal muscle characteristics are among the more established outcomes resulting from these rehabilitation techniques. Moreover, both aerobic and resistance exercise training appear to portend a low risk to patients with HF when appropriate exercise prescription methods are followed. While the aforementioned training techniques will undoubtedly continue to be at the center of a well-formulated rehabilitation program, other adjunctive interventions, which are presently underutilized in clinical practice, may prove beneficial in patients with HF. Specifically, both neuromuscular electrical stimulation (NMES) and inspiratory muscle training (IMT) appear to significantly improve several physiologic, exercise, symptomatologic, and quality-of-life parameters. NMES targets skeletal muscle abnormalities, whereas IMT primarily targets the weakened respiratory musculature, both often encountered in patients with HF. A PubMed search using relevant key words identified 19 original investigations examining the impact of NMES (13 studies) and IMT (6 studies) training programs in patients with HF. The resultant review (1) provides a summary of the original research outcomes of both NMES and IMT in patients with HF; (2) addresses current research gaps, providing a direction for future investigations; and (3) provides clinical scenarios where NMES and IMT may prove to be beneficial during the rehabilitation of patients with HF.

  7. Role of bronchodilation and pattern of breathing in increasing tidal expiratory flow with progressive induced hypercapnia in chronic obstructive pulmonary disease.

    Science.gov (United States)

    Finucane, Kevin E; Singh, Bhajan

    2018-01-01

    Hypercapnia (HC) in vitro relaxes airway smooth muscle; in vivo, it increases respiratory effort, tidal expiratory flows (V̇ exp ), and, by decreasing inspiratory duration (Ti), increases elastic recoil pressure (Pel) via lung viscoelasticity; however, its effect on airway resistance is uncertain. We examined the contributions of bronchodilation, Ti, and expiratory effort to increasing V̇ exp with progressive HC in 10 subjects with chronic obstructive pulmonary disease (COPD): mean forced expiratory volume in 1 s (FEV 1 ) 53% predicted. Lung volumes (Vl), V̇ exp , esophageal pressure (Pes), Ti, and end-tidal Pco 2 ([Formula: see text]) were measured during six tidal breaths followed by an inspiratory capacity (IC), breathing air, and at three levels of HC. V̇ exp and V̇ with submaximal forced vital capacities breathing air (V̇ sFVC ) were compared. Pulmonary resistance ( Rl) was measured from the Pes-V̇ relationship. V̇ exp and Pes at end-expiratory lung volume (EELV) + 0.3 tidal volume [V̇ (0.3Vt) and Pes (0.3Vt) , respectively], Ti, and Rl correlated with [Formula: see text] ( P pulmonary disease (COPD), progressive HC increases tidal expiratory flows by inducing bronchodilation and via an increased rate of inspiration and lung viscoelasticity, a probable increase in lung elastic recoil pressure, both changes increasing expiratory flows, promoting lung emptying and a stable end-expiratory volume. Bronchodilation with HC occurred despite optimal standard bronchodilator therapy, suggesting that in COPD further bronchodilation is possible.

  8. Considerations in applying on-line IC techniques to BWR's

    International Nuclear Information System (INIS)

    Kaleda, R.J.

    1992-01-01

    Ion-Chromatography (IC) has moved from its traditional role as a laboratory analytical tool to a real time, dynamic, on-line measurement device to follow ppb and sub-ppb concentrations of deleterious impurities in nuclear power plants. Electric Power Research Institute (EPRI), individual utilities, and industry all have played significant roles in effecting the transition. This paper highlights considerations and the evolution in current on-line Ion Chromatography systems. The first applications of on-line techniques were demonstrated by General Electric (GE) under EPRI sponsorship at Rancho Seco (1980), Calvert Cliffs, and McGuire nuclear units. The primary use was for diagnostic purposes. Today the on-line IC applications have been expanded to include process control and routine plant monitoring. Current on-line IC's are innovative in design, promote operational simplicity, are modular for simplified maintenance and repair, and use field-proven components which enhance reliability. Conductivity detection with electronic or chemical suppression and spectrometric detection techniques are intermixed in applications. Remote multi-point sample systems have addressed memory effects. Early applications measured ionic species in the part per billion range. Today reliable part per trillion measurements are common for on-line systems. Current systems are meeting the challenge of EPRI guideline requirements. Today's on-line IC's, with programmed sampling systems, monitor fluid streams throughout a power plant, supplying data that can be trended, stored and retrieved easily. The on-line IC has come of age. Many technical challenges were overcome to achieve today's IC

  9. Preliminary I&C Design for LORELEI

    International Nuclear Information System (INIS)

    Korotkin, S.; Kaufman, Y.; Guttmann, E. B.; Levy, S.; Amidan, D.; Gdalyho, B.; Cahana, T.; Ellenbogen, A.; Arad, M.; Weiss, Y.; Sasson, A.; Ferry, L.; Bourrelly, F.; Cohen, Y.

    2014-01-01

    This document summarizes the preliminary I&C design for LORELEI experiment The preliminary design deals with considerations regarding appropriate safety and service instrumentation. The determined closed loop control rules for temperature and position will be implemented in the detailed design. The Computer Aided Operator Decisions System (CAODS) will be used for prediction of hot spot temperature and thickness of oxidation layer using Baker-Just correlation. The proposed hybrid simulation system comprising of both virtual and real hardware will be in-cooperated for LORELEI verification. It will perform both integration cold tests for a partial hardware loop and virtual tests for the final I&C design

  10. Adopting De Novo Programming Approach on IC Design Service Firms Resources Integration

    Directory of Open Access Journals (Sweden)

    James K. C. Chen

    2014-01-01

    Full Text Available The semiconductor industry has very important position in computer industry, ICT field, and new electronic technology developing. The IC design service is one of key factor of semiconductor industry development. There are more than 365 IC design service firms have been established around Hsinchu Science Park in Taiwan. Building an efficient planning model for IC design service firm resources integrating is very interest issue. This study aims to construct a planning model for IC design service firm implementation resources integration. This study uses the De Novo programming as an approach of criteria alternative to achieve optimal resource allocation on IC design firm. Results show the IC design service firm should conduct open innovation concept and utilizes design outsourcing obtains cost down and enhance IC design service business performance. This plan model of De Novo programming is not only for IC design service firm and also can apply to the other industrial implementation strategic alliance/integrating resource. This plan model is a universal model for the others industries field.

  11. Phlorotannin Extracts from Fucales Characterized by HPLC-DAD-ESI-MSn: Approaches to Hyaluronidase Inhibitory Capacity and Antioxidant Properties

    Science.gov (United States)

    Ferreres, Federico; Lopes, Graciliana; Gil-Izquierdo, Angel; Andrade, Paula B.; Sousa, Carla; Mouga, Teresa; Valentão, Patrícia

    2012-01-01

    Purified phlorotannin extracts from four brown seaweeds (Cystoseira nodicaulis (Withering) M. Roberts, Cystoseira tamariscifolia (Hudson) Papenfuss, Cystoseira usneoides (Linnaeus) M. Roberts and Fucus spiralis Linnaeus), were characterized by HPLC-DAD-ESI-MSn. Fucophloroethol, fucodiphloroethol, fucotriphloroethol, 7-phloroeckol, phlorofucofuroeckol and bieckol/dieckol were identified. The antioxidant activity and the hyaluronidase (HAase) inhibitory capacity exhibited by the extracts were also assessed. A correlation between the extracts activity and their chemical composition was established. F. spiralis, the species presenting higher molecular weight phlorotannins, generally displayed the strongest lipid peroxidation inhibitory activity (IC50 = 2.32 mg/mL dry weight) and the strongest HAase inhibitory capacity (IC50 = 0.73 mg/mL dry weight). As for superoxide radical scavenging, C. nodicaulis was the most efficient species (IC50 = 0.93 mg/mL dry weight), followed by F. spiralis (IC50 = 1.30 mg/mL dry weight). These results show that purified phlorotannin extracts have potent capabilities for preventing and slowing down the skin aging process, which is mainly associated with free radical damage and with the reduction of hyaluronic acid concentration, characteristic of the process. PMID:23222802

  12. PENGARUH IC TERHADAP KINERJA KEUANGAN PERUSAHAAN PERBANKAN PERIODE 2005-2007

    Directory of Open Access Journals (Sweden)

    Subkhan -

    2012-03-01

    Full Text Available Tujuan dari penelitian ini adalah untuk meneliti pengaruh intellectual capital (IC perusahaan pada kinerja keuangan mereka. Penelitian ini menggunakan Public Framework dan data dari 57 sektor perbankan Indonesia yang tercatat antara tahun 2005 dan 2007 pada Indonesian Stock Exchange. Penelitian ini menggunakan partial least square (PLS untuk menganalisis data. 3 elemen IC dan kinerja perusahaan dites dalam penelitian ini. Hasilnya memperlihatkan bahwa IC dan kinerja keuangan mempunyai pengaruh yang signifikan, VACA mempunyai pengaruh yang signifikan terhadap kinerja keuangan, VAHU mempuyai pengaruh yang signifikan  terhadap kinerja keuangan, dan STVA mempunyai pengaruh yang signifikan terhadap kinerja keuangan. Abstract The objective of this study is to investigate the influence of firm’s intellectual capital (IC on their financial performance. This paper uses Public Framework and data from 57 Indonesian banking sectors listed between 2005 and 2007 on the Indonesian Stock Exchange. This study uses partial least square (PLS for data analysis. Three elements of IC and company performances are tested by this study. The results show that IC and financial performance have significant influence, VACA has significant influence to financial performance, VAHU has significant influence to financial performance, and STVA has significant influence to financial performance.Keywords: intellectual capital; financial performance

  13. ICS logging solution for network-based attacks using Gumistix technology

    Science.gov (United States)

    Otis, Jeremy R.; Berman, Dustin; Butts, Jonathan; Lopez, Juan

    2013-05-01

    Industrial Control Systems (ICS) monitor and control operations associated with the national critical infrastructure (e.g., electric power grid, oil and gas pipelines and water treatment facilities). These systems rely on technologies and architectures that were designed for system reliability and availability. Security associated with ICS was never an inherent concern, primarily due to the protections afforded by network isolation. However, a trend in ICS operations is to migrate to commercial networks via TCP/IP in order to leverage commodity benefits and cost savings. As a result, system vulnerabilities are now exposed to the online community. Indeed, recent research has demonstrated that many exposed ICS devices are being discovered using readily available applications (e.g., ShodanHQ search engine and Google-esque queries). Due to the lack of security and logging capabilities for ICS, most knowledge about attacks are derived from real world incidents after an attack has already been carried out and the damage has been done. This research provides a method for introducing sensors into the ICS environment that collect information about network-based attacks. The sensors are developed using an inexpensive Gumstix platform that can be deployed and incorporated with production systems. Data obtained from the sensors provide insight into attack tactics (e.g., port scans, Nessus scans, Metasploit modules, and zero-day exploits) and characteristics (e.g., attack origin, frequency, and level of persistence). Findings enable security professionals to draw an accurate, real-time awareness of the threats against ICS devices and help shift the security posture from reactionary to preventative.

  14. PELE-IC test problems

    International Nuclear Information System (INIS)

    Gong, E.Y.; Alexander, E.E.; McMaster, W.H.; Quinones, D.F.

    1979-01-01

    This report provides prospective users of the Lawrence Livermore Laboratory (LLL) fluid-structure interaction computer code, PELE-IC, a variety of test problems for verifying the code on CDC 7600 computer systems at facilities external to the LLL environment. The test problems have been successfully run on CDC 7600 computers at the LLL and Lawrence Berkeley Laboratory (LBL) computer centers

  15. Applicability of the DPPH assay for evaluating the antioxidant capacity of food additives - inter-laboratory evaluation study -.

    Science.gov (United States)

    Shimamura, Tomoko; Sumikura, Yoshihiro; Yamazaki, Takeshi; Tada, Atsuko; Kashiwagi, Takehiro; Ishikawa, Hiroya; Matsui, Toshiro; Sugimoto, Naoki; Akiyama, Hiroshi; Ukeda, Hiroyuki

    2014-01-01

    An inter-laboratory evaluation study was conducted in order to evaluate the antioxidant capacity of food additives by using a 1,1-diphenyl-2-picrylhydrazyl (DPPH) assay. Four antioxidants used as existing food additives (i.e., tea extract, grape seed extract, enju extract, and d-α-tocopherol) and 6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid (Trolox) were used as analytical samples, and 14 laboratories participated in this study. The repeatability relative standard deviation (RSD(r)) of the IC50 of Trolox, four antioxidants, and the Trolox equivalent antioxidant capacity (TEAC) were 1.8-2.2%, 2.2-2.9%, and 2.1-2.5%, respectively. Thus, the proposed DPPH assay showed good performance within the same laboratory. The reproducibility relative standard deviation (RSD(R)) of IC50 of Trolox, four antioxidants, and TEAC were 4.0-7.9%, 6.0-11%, and 3.7-9.3%, respectively. The RSD(R)/RSD(r) values of TEAC were lower than, or nearly equal to, those of IC50 of the four antioxidants, suggesting that the use of TEAC was effective for reducing the variance among the laboratories. These results showed that the proposed DPPH assay could be used as a standard method to evaluate the antioxidant capacity of food additives.

  16. Development of grouped icEEG for the study of cognitive processing

    Directory of Open Access Journals (Sweden)

    Cihan Mehmet Kadipasaoglu

    2015-07-01

    Full Text Available Invasive intracranial EEG (icEEG offers a unique opportunity to study human cognitive networks at an unmatched spatiotemporal resolution. To date, the contributions of icEEG have been limited to the individual-level analyses or cohorts whose data are not integrated in any way. Here we discuss how grouped approaches to icEEG overcome challenges related to sparse-sampling, correct for individual variations in response and provide statistically valid models of brain activity in a population. By the generation of whole-brain activity maps, grouped icEEG enables the study of intra and interregional dynamics between distributed cortical substrates exhibiting task-dependent activity. In this fashion, grouped icEEG analyses can provide significant advances in understanding the mechanisms by which cortical networks give rise to cognitive functions.

  17. Pulmonary dysfunctions, oxidative stress and DNA damage in brick kiln workers.

    Science.gov (United States)

    Kaushik, R; Khaliq, F; Subramaneyaan, M; Ahmed, R S

    2012-11-01

    Brick kilns in the suburban areas in developing countries pose a big threat to the environment and hence the health of their workers and people residing around them. The present study was planned to assess the lung functions, oxidative stress parameters and DNA damage in brick kiln workers. A total of 31 male subjects working in brick kiln, and 32 age, sex and socioeconomic status matched controls were included in the study. The lung volumes, capacities and flow rates, namely, forced expiratory volume in first second (FEV(1)), forced vital capacity (FVC), FEV(1)/FVC, expiratory reserve volume, inspiratory capacity (IC), maximal expiratory flow when 50% of FVC is remaining to be expired, maximum voluntary ventilation, peak expiratory flow rate and vital capacity were significantly decreased in the brick kiln workers. Increased oxidative stress as evidenced by increased malonedialdehyde levels and reduced glutathione content, glutathione S-transferase activity and ferric reducing ability of plasma were observed in the study group when compared with controls. Our results indicate a significant correlation between oxidative stress parameters and pulmonary dysfunction, which may be due to silica-induced oxidative stress and resulting lung damage.

  18. Extreme low-power mixed signal IC design

    CERN Document Server

    Tajalli, Armin

    2010-01-01

    This book describes a completely novel class of techniques for designing ultra-low-power integrated circuits (ICs). In many applications such as battery operated systems and battery-less (energy-scavenging) systems, power dissipation is a critical parameter. As a result, there is a growing demand for reducing the power (energy) consumption in ICs to extremely low levels, not achievable by using classical ""subthreshold CMOS"" techniques. This book introduces a new family of ""subthreshold circuits"" called ""source-coupled circuits"". This family of circuits can be used for implementing digita

  19. Design Developing of IC- Model Using VHDL

    International Nuclear Information System (INIS)

    Inzar-Anas

    2005-01-01

    In present, the electronic design required to become simple, small and flexible. The physical dimension of IC and number of pin can be significantly reduced while the flexibility and compatibility of IC was not change. Implementation of VHDL(VHSIC Hardware Description Language) seem as a great progress in the design of digital circuit. By using this language designing of model can be more simple, flexible and efficient. This paper was purposed to introduce VHDL and its features. Sample in modeling to illustrate the advantage of VHDL will also be described. (author)

  20. Sensitivity Study on Availability of I&C Components Using Bayesian Network

    Directory of Open Access Journals (Sweden)

    Rahman Khalil Ur

    2013-01-01

    Full Text Available The objective of this study is to find out the impact of instrumentation and control (I&C components on the availability of I&C systems in terms of sensitivity analysis using Bayesian network. The analysis has been performed on I&C architecture of reactor protection system. The analysis results would be applied to develop I&C architecture which will meet the desire reliability features and save cost. RPS architecture unavailability P(x=0 and availability P(x=1 were estimated to 6.1276E-05 and 9.9994E-01 for failure (0 and perfect (1 states, respectively. The impact of I&C components on overall system risk has been studied in terms of risk achievement worth (RAW and risk reduction worth (RRW. It is found that circuit breaker failure (TCB, bi-stable processor (BP, sensor transmitter (TR, and pressure transmitter (PT have high impact on risk. The study concludes and recommends that circuit breaker bi-stable processor should be given more consideration while designing I&C architecture.

  1. Development of brain injury criteria (BrIC).

    Science.gov (United States)

    Takhounts, Erik G; Craig, Matthew J; Moorhouse, Kevin; McFadden, Joe; Hasija, Vikas

    2013-11-01

    Rotational motion of the head as a mechanism for brain injury was proposed back in the 1940s. Since then a multitude of research studies by various institutions were conducted to confirm/reject this hypothesis. Most of the studies were conducted on animals and concluded that rotational kinematics experienced by the animal's head may cause axonal deformations large enough to induce their functional deficit. Other studies utilized physical and mathematical models of human and animal heads to derive brain injury criteria based on deformation/pressure histories computed from their models. This study differs from the previous research in the following ways: first, it uses two different detailed mathematical models of human head (SIMon and GHBMC), each validated against various human brain response datasets; then establishes physical (strain and stress based) injury criteria for various types of brain injury based on scaled animal injury data; and finally, uses Anthropomorphic Test Devices (ATDs) (Hybrid III 50th Male, Hybrid III 5th Female, THOR 50th Male, ES-2re, SID-IIs, WorldSID 50th Male, and WorldSID 5th Female) test data (NCAP, pendulum, and frontal offset tests) to establish a kinematically based brain injury criterion (BrIC) for all ATDs. Similar procedures were applied to college football data where thousands of head impacts were recorded using a six degrees of freedom (6 DOF) instrumented helmet system. Since animal injury data used in derivation of BrIC were predominantly for diffuse axonal injury (DAI) type, which is currently an AIS 4+ injury, cumulative strain damage measure (CSDM) and maximum principal strain (MPS) were used to derive risk curves for AIS 4+ anatomic brain injuries. The AIS 1+, 2+, 3+, and 5+ risk curves for CSDM and MPS were then computed using the ratios between corresponding risk curves for head injury criterion (HIC) at a 50% risk. The risk curves for BrIC were then obtained from CSDM and MPS risk curves using the linear relationship

  2. Prion seeding activities of mouse scrapie strains with divergent PrPSc protease sensitivities and amyloid plaque content using RT-QuIC and eQuIC.

    Directory of Open Access Journals (Sweden)

    Sarah Vascellari

    Full Text Available Different transmissible spongiform encephalopathy (TSE-associated forms of prion protein (e.g. PrP(Sc can vary markedly in ultrastructure and biochemical characteristics, but each is propagated in the host. PrP(Sc propagation involves conversion from its normal isoform, PrP(C, by a seeded or templated polymerization mechanism. Such a mechanism is also the basis of the RT-QuIC and eQuIC prion assays which use recombinant PrP (rPrP(Sen as a substrate. These ultrasensitive detection assays have been developed for TSE prions of several host species and sample tissues, but not for murine models which are central to TSE pathogenesis research. Here we have adapted RT-QuIC and eQuIC to various murine prions and evaluated how seeding activity depends on glycophosphatidylinositol (GPI anchoring and the abundance of amyloid plaques and protease-resistant PrP(Sc (PrP(Res. Scrapie brain dilutions up to 10(-8 and 10(-13 were detected by RT-QuIC and eQuIC, respectively. Comparisons of scrapie-affected wild-type mice and transgenic mice expressing GPI anchorless PrP showed that, although similar concentrations of seeding activity accumulated in brain, the heavily amyloid-laden anchorless mouse tissue seeded more rapid reactions. Next we compared seeding activities in the brains of mice with similar infectivity titers, but widely divergent PrP(Res levels. For this purpose we compared the 263K and 139A scrapie strains in transgenic mice expressing P101L PrP(C. Although the brains of 263K-affected mice had little immunoblot-detectable PrP(Res, RT-QuIC indicated that seeding activity was comparable to that associated with a high-PrP(Res strain, 139A. Thus, in this comparison, RT-QuIC seeding activity correlated more closely with infectivity than with PrP(Res levels. We also found that eQuIC, which incorporates a PrP(Sc immunoprecipitation step, detected seeding activity in plasma from wild-type and anchorless PrP transgenic mice inoculated with 22L, 79A and/or RML

  3. Positioning of electrode plane systematically influences EIT imaging.

    Science.gov (United States)

    Krueger-Ziolek, Sabine; Schullcke, Benjamin; Kretschmer, Jörn; Müller-Lisse, Ullrich; Möller, Knut; Zhao, Zhanqi

    2015-06-01

    Up to now, the impact of electrode positioning on electrical impedance tomography (EIT) had not been systematically analyzed due to the lack of a reference method. The aim of the study was to determine the impact of electrode positioning on EIT imaging in spontaneously breathing subjects at different ventilation levels with our novel lung function measurement setup combining EIT and body plethysmography. EIT measurements were conducted in three transverse planes between the 3rd and 4th intercostal space (ICS), at the 5th ICS and between the 6th and 7th ICS (named as cranial, middle and caudal) on 12 healthy subjects. Pulmonary function tests were performed simultaneously by body plethysmography to determine functional residual capacity (FRC), vital capacity (VC), tidal volume (VT), expiratory reserve volume (ERV), and inspiratory reserve volume (IRV). Ratios of impedance changes and body plethysmographic volumes were calculated for every thorax plane (ΔIERV/ERV, ΔIVT/VT and ΔIIRV/IRV). In all measurements of a subject, FRC values and VC values differed ≤5%, which confirmed that subjects were breathing at comparable end-expiratory levels and with similar efforts. In the cranial thorax plane the normalized ΔIERV/ERV ratio in all subjects was significantly higher than the normalized ΔIIRV/IRV ratio whereas the opposite was found in the caudal chest plane. No significant difference between the two normalized ratios was found in the middle thoracic plane. Depending on electrode positioning, impedance to volume ratios may either increase or decrease in the same lung condition, which may lead to opposite clinical decisions.

  4. Effects of Air Stacking Maneuver on Cough Peak Flow and Chest Wall Compartmental Volumes of Subjects With Amyotrophic Lateral Sclerosis.

    Science.gov (United States)

    Sarmento, Antonio; Resqueti, Vanessa; Dourado-Júnior, Mario; Saturnino, Lailane; Aliverti, Andrea; Fregonezi, Guilherme; de Andrade, Armele Dornelas

    2017-11-01

    To assess the acute effects of air stacking on cough peak flow (CPF) and chest wall compartmental volumes of persons with amyotrophic lateral sclerosis (ALS) versus healthy subjects positioned at 45° body inclination. Cross-sectional study with a matched-pair design. University hospital. Persons (N=24) with ALS (n=12) and age-matched healthy subjects (n=12). CPF, chest wall compartmental inspiratory capacity, chest wall vital capacity, chest wall tidal volume and operational volumes, breathing pattern, and percentage of contribution of the compartments to the inspired volume were measured by optoelectronic plethysmography. Compared with healthy subjects, significantly lower CPF (P=.007), chest wall compartmental inspiratory capacity (Pprotocol in the healthy subjects, mainly because of end-inspiratory (P<.001) and abdominal volumes (P=.008). No significant differences were observed in percentage of contribution of the compartments to the inspired volume and end-expiratory volume of both groups. No significant differences were found in chest wall tidal volume, operational volume, and breathing pattern in persons with ALS. Air stacking is effective in increasing CPF, chest wall compartmental inspiratory capacity, and chest wall vital capacity of persons with ALS with no hyperinflation. Differences in compartmental volume contributions are probably because of lung and chest wall physiological changes. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  5. Treinamento de músculos inspiratórios em pacientes com quadriplegia Inspiratory muscle training in quadriplegic patients

    Directory of Open Access Journals (Sweden)

    Janne Marques Silveira

    2010-06-01

    Full Text Available OBJETIVO: Determinar se o treinamento de músculos inspiratórios pode aumentar a força e endurance desses músculos em pacientes com quadriplegia. MÉTODOS: Oito pacientes quadriplégicos (7 homens e 1 mulher com lesão medular cervical entre C4 e C7 foram submetidos ao treinamento de músculos inspiratórios utilizando-se um resistor de carga linear ajustado em 30% da PImáx. As sessões de treinamento foram realizadas com os pacientes sentados 5 vezes por semana por 8 semanas. Tempo de endurance, PImáx, PEmáx e CVF foram medidos antes do treinamento e nas semanas 4 e 8. RESULTADOS: Em comparação ao valor basal médio, houve um aumento da PImáx, mensurada na posição sentada, nas semanas 4 e 8 (-83,0 ± 18,9 cmH2O vs. -104,0 ± 19,4 e -111,3 ± 22,7 cmH2O. Houve aumento da PEmáx, também na posição sentada, na semana 4 (de 36,8 ± 8,1 a 42,6 ± 8,8 cmH2O. Houve uma melhora na FVC na 4ª semana (de 2,1 ± 0,8 a 2,5 ± 0,6 L, representando um incremento de 24 ± 22%. O tempo de endurance (sentado não apresentou um aumento significativo entre o momento basal e a semana 8 (29,8 ± 21,0 min vs. 35,9 ± 15,5 min; aumento de 173 ± 233%. CONCLUSÕES: Pacientes com quadriplegia podem se beneficiar com o treinamento com baixas cargas (30% da PImáx, com melhora da força dos músculos inspiratórios, CVF e efetividade dos músculos expiratórios.OBJECTIVE: To determine whether inspiratory muscle training can increase strength and endurance of these muscles in quadriplegic patients. METHODS: Eight quadriplegic patients (7 males and 1 female with injury to the lower cervical spine (segments C4-C7 were submitted to inspiratory muscle training with a threshold inspiratory muscle trainer adjusted to 30% of MIP. The training sessions were carried out with the patients in a sitting position, 5 days a week for 8 weeks. Endurance time, MIP, MEP and FVC were determined at baseline, week 4 and week 8. RESULTS: In comparison with the mean baseline value

  6. Mismatch and noise in modern IC processes

    CERN Document Server

    Marshall, Andrew

    2009-01-01

    Component variability, mismatch, and various noise effects are major contributors to design limitations in most modern IC processes. Mismatch and Noise in Modern IC Processes examines these related effects and how they affect the building block circuits of modern integrated circuits, from the perspective of a circuit designer.Variability usually refers to a large scale variation that can occur on a wafer to wafer and lot to lot basis, and over long distances on a wafer. This phenomenon is well understood and the effects of variability are included in most integrated circuit design with the use

  7. 30 CFR 57.22209 - Auxiliary fans (I-C mines).

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Auxiliary fans (I-C mines). 57.22209 Section 57... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22209 Auxiliary fans (I-C mines). Electric auxiliary fans shall be approved by MSHA under the applicable requirements of 30 CFR part 18...

  8. Identification of signals that facilitate isoform specific nucleolar localization of myosin IC

    Energy Technology Data Exchange (ETDEWEB)

    Schwab, Ryan S.; Ihnatovych, Ivanna; Yunus, Sharifah Z.S.A.; Domaradzki, Tera [Department of Physiology and Biophysics, University at Buffalo—State University of New York, Buffalo, NY (United States); Hofmann, Wilma A., E-mail: whofmann@buffalo.edu [Department of Physiology and Biophysics, University at Buffalo—State University of New York, Buffalo, NY (United States)

    2013-05-01

    Myosin IC is a single headed member of the myosin superfamily that localizes to the cytoplasm and the nucleus, where it is involved in transcription by RNA polymerases I and II, intranuclear transport, and nuclear export. In mammalian cells, three isoforms of myosin IC are expressed that differ only in the addition of short isoform-specific N-terminal peptides. Despite the high sequence homology, the isoforms show differences in cellular distribution, in localization to nuclear substructures, and in their interaction with nuclear proteins through yet unknown mechanisms. In this study, we used EGFP-fusion constructs that express truncated or mutated versions of myosin IC isoforms to detect regions that are involved in isoform-specific localization. We identified two nucleolar localization signals (NoLS). One NoLS is located in the myosin IC isoform B specific N-terminal peptide, the second NoLS is located upstream of the neck region within the head domain. We demonstrate that both NoLS are functional and necessary for nucleolar localization of specifically myosin IC isoform B. Our data provide a first mechanistic explanation for the observed functional differences between the myosin IC isoforms and are an important step toward our understanding of the underlying mechanisms that regulate the various and distinct functions of myosin IC isoforms. - Highlights: ► Two NoLS have been identified in the myosin IC isoform B sequence. ► Both NoLS are necessary for myosin IC isoform B specific nucleolar localization. ► First mechanistic explanation of functional differences between the isoforms.

  9. Prometheus Reactor I&C Software Development Methodology, for Action

    Energy Technology Data Exchange (ETDEWEB)

    T. Hamilton

    2005-07-30

    The purpose of this letter is to submit the Reactor Instrumentation and Control (I&C) software life cycle, development methodology, and programming language selections and rationale for project Prometheus to NR for approval. This letter also provides the draft Reactor I&C Software Development Process Manual and Reactor Module Software Development Plan to NR for information.

  10. Comparing dynamic hyperinflation and associated dyspnea induced by metronome-paced tachypnea versus incremental exercise.

    Science.gov (United States)

    Calligaro, Gregory L; Raine, Richard I; Bateman, Mary E; Bateman, Eric D; Cooper, Christopher B

    2014-02-01

    Dynamic hyperinflation (DH) during exercise is associated with both dyspnea and exercise limitation in COPD. Metronome-paced tachypnoea (MPT) is a simple alternative for studying DH. We compared MPT with exercise testing (XT) as methods of provoking DH, and assessed their relationship with dyspnea. We studied 24 patients with moderate COPD (FEV1 59 ± 9% predicted) after inhalation of ipratropium/salbutamol combination or placebo in a double-blind, crossover design. Inspiratory capacity (IC) was measured at baseline and after 30 seconds of MPT with breathing frequencies (fR) of 20, 30 and 40 breaths/min and metronome-defined I:E ratios of 1:1 and 1:2, in random sequence, followed by incremental cycle ergometry with interval determinations of IC. DH was defined as a decline in IC from baseline (∆IC) for both methods. Dyspnea was assessed using a Borg CR-10 scale. ∆IC during MPT was greater with higher fR and I:E ratio of 1:1 versus 1:2, and less when patients were treated with bronchodilator rather than placebo (P = 0.032). DH occurred during 19 (40%) XTs, and during 35 (73%) tests using MPT. Eleven of 18 (61%) non-congruent XTs (where DH occurred on MPT but not XT) terminated before fR of 40 breaths/min was reached. Although greater during XT, the intensity of dyspnea bore no relationship to DH during either MPT and XT. MPT at 40 breaths/min and I:E of 1:1 elicits the greatest ∆IC, and is a more sensitive method for demonstrating DH. The relationship between DH and dyspnea is complex and not determined by DH alone.

  11. Comparison of different inspiratory triggering settings in automated ventilators during cardiopulmonary resuscitation in a porcine model.

    Science.gov (United States)

    Tan, Dingyu; Xu, Jun; Shao, Shihuan; Fu, Yangyang; Sun, Feng; Zhang, Yazhi; Hu, Yingying; Walline, Joseph; Zhu, Huadong; Yu, Xuezhong

    2017-01-01

    Mechanical ventilation via automated in-hospital ventilators is quite common during cardiopulmonary resuscitation. It is not known whether different inspiratory triggering sensitivity settings of ordinary ventilators have different effects on actual ventilation, gas exchange and hemodynamics during resuscitation. 18 pigs enrolled in this study were anaesthetized and intubated. Continuous chest compressions and mechanical ventilation (volume-controlled mode, 100% O2, respiratory rate 10/min, and tidal volumes 10ml/kg) were performed after 3 minutes of ventricular fibrillation. Group trig-4, trig-10 and trig-20 (six pigs each) were characterized by triggering sensitivities of 4, 10 and 20 (cmH2O for pressure-triggering and L/min for flow-triggering), respectively. Additionally, each pig in each group was mechanically ventilated using three types of inspiratory triggering (pressure-triggering, flow-triggering and turned-off triggering) of 5 minutes duration each, and each animal matched with one of six random assortments of the three different triggering settings. Blood gas samples, respiratory and hemodynamic parameters for each period were all collected and analyzed. In each group, significantly lower actual respiratory rate, minute ventilation volume, mean airway pressure, arterial pH, PaO2, and higher end-tidal carbon dioxide, aortic blood pressure, coronary perfusion pressure, PaCO2 and venous oxygen saturation were observed in the ventilation periods with a turned-off triggering setting compared to those with pressure- or flow- triggering (all PVentilation with pressure- or flow-triggering tends to induce hyperventilation and deteriorating gas exchange and hemodynamics during CPR. A turned-off patient triggering or a pressure-triggering of 20 cmH2O is preferred for ventilation when an ordinary inpatient hospital ventilator is used during resuscitation.

  12. Simulation of SEU transients in CMOS ICs

    International Nuclear Information System (INIS)

    Kaul, N.; Bhuva, B.L.; Kerns, S.E.

    1991-01-01

    This paper reports that available analytical models of the number of single-event-induced errors (SEU) in combinational logic systems are not easily applicable to real integrated circuits (ICs). An efficient computer simulation algorithm set, SITA, predicts the vulnerability of data stored in and processed by complex combinational logic circuits to SEU. SITA is described in detail to allow researchers to incorporate it into their error analysis packages. Required simulation algorithms are based on approximate closed-form equations modeling individual device behavior in CMOS logic units. Device-level simulation is used to estimate the probability that ion-device interactions produce erroneous signals capable of propagating to a latch (or n output node), and logic-level simulation to predict the spread of such erroneous, latched information through the IC. Simulation results are compared to those from SPICE for several circuit and logic configurations. SITA results are comparable to this established circuit-level code, and SITA can analyze circuits with state-of-the-art device densities (which SPICE cannot). At all IC complexity levels, SITAS offers several factors of 10 savings in simulation time over SPICE

  13. The Search for Wolf-Rayet Stars in IC10

    Science.gov (United States)

    Tehrani, Katie; Crowther, Paul; Archer, Isabelle

    2017-11-01

    We present a deep imaging and spectroscopic survey of the Local Group starburst galaxy IC10 using Gemini North/GMOS to unveil the global Wolf-Rayet population. It has previously been suggested that for IC10 to follow the WC/WN versus metallicity dependence seen in other Local Group galaxies, a large WN population must remain undiscovered. Our search revealed 3 new WN stars, and 5 candidates awaiting confirmation, providing little evidence to support this claim. We also compute an updated nebular derived metallicity of log(O/H)+12=8.40 +/- 0.04 for the galaxy using the direct method. Inspection of IC10 WR average line luminosities show these stars are more similar to their LMC, rather than SMC counterparts.

  14. Evaluation of ultimate load bearing capacity of the primary containment of a typical 540 MWe Indian PHWR

    International Nuclear Information System (INIS)

    Ray, Indrajit; Roy, Raghupati; Verma, U.S.P.; Warudkar, A.S.

    2003-01-01

    This paper presents the analysis of the Inner Containment Structure (ICS) of a typical 540 MWe Indian PHWR for the purpose of evaluating its ultimate load bearing capacity (ULBC) under beyond postulated design basis accident (DBA) scenario. The methodology adopted for the non-linear analysis of the prestressed concrete ICS including the various issues, viz. behaviour of concrete under compression and tension, tension stiffening, cracked shear modulus etc. have also been discussed in this paper. The effect of accident temperature on ULBC has been studied and discussed in this paper. This paper also discusses about the study carried out for mesh sensitivity of the finite element (FE) discretization on ULBC of ICS in the non-linear range. Based on the detailed analysis, the factor of safety of the ICS under beyond postulated DBA scenario has been evaluated. (author)

  15. A quick on-line state of health estimation method for Li-ion battery with incremental capacity curves processed by Gaussian filter

    Science.gov (United States)

    Li, Yi; Abdel-Monem, Mohamed; Gopalakrishnan, Rahul; Berecibar, Maitane; Nanini-Maury, Elise; Omar, Noshin; van den Bossche, Peter; Van Mierlo, Joeri

    2018-01-01

    This paper proposes an advanced state of health (SoH) estimation method for high energy NMC lithium-ion batteries based on the incremental capacity (IC) analysis. IC curves are used due to their ability of detect and quantify battery degradation mechanism. A simple and robust smoothing method is proposed based on Gaussian filter to reduce the noise on IC curves, the signatures associated with battery ageing can therefore be accurately identified. A linear regression relationship is found between the battery capacity with the positions of features of interest (FOIs) on IC curves. Results show that the developed SoH estimation function from one single battery cell is able to evaluate the SoH of other batteries cycled under different cycling depth with less than 2.5% maximum errors, which proves the robustness of the proposed method on SoH estimation. With this technique, partial charging voltage curves can be used for SoH estimation and the testing time can be therefore largely reduced. This method shows great potential to be applied in reality, as it only requires static charging curves and can be easily implemented in battery management system (BMS).

  16. Application of IC Card License for Road Transportation in Commercial Vehicles Supervision and Service

    Directory of Open Access Journals (Sweden)

    Li Weiwei

    2016-01-01

    Full Text Available IC card electronic license for road transport includes the IC card commercial vehicle’s certificate and IC card practitioner’s qualification certificate. In China, the IC card electronic license for road transport is the electronic ID card which must be carried by each commercial vehicles and practitioners. This paper briefly introduces the basic situation, data format and security keys architecture of IC card electronic license for road transportation of China. In order to strengthen the supervision and service of commercial vehicles, this paper puts forward the overall application framework of IC card electronic license for road transport. The application examples of IC card license in the supervision of passenger station, dangerous goods transport management, governance overload and logistics park and port area management are discussed. The practical application results show that the application of IC card electronic license for road transport is an important technical means to improve the supervision ability and service quality of the road transportation industry.

  17. ICECAP: an integrated, general-purpose, automation-assisted IC50/EC50 assay platform.

    Science.gov (United States)

    Li, Ming; Chou, Judy; King, Kristopher W; Jing, Jing; Wei, Dong; Yang, Liyu

    2015-02-01

    IC50 and EC50 values are commonly used to evaluate drug potency. Mass spectrometry (MS)-centric bioanalytical and biomarker labs are now conducting IC50/EC50 assays, which, if done manually, are tedious and error-prone. Existing bioanalytical sample preparation automation systems cannot meet IC50/EC50 assay throughput demand. A general-purpose, automation-assisted IC50/EC50 assay platform was developed to automate the calculations of spiking solutions and the matrix solutions preparation scheme, the actual spiking and matrix solutions preparations, as well as the flexible sample extraction procedures after incubation. In addition, the platform also automates the data extraction, nonlinear regression curve fitting, computation of IC50/EC50 values, graphing, and reporting. The automation-assisted IC50/EC50 assay platform can process the whole class of assays of varying assay conditions. In each run, the system can handle up to 32 compounds and up to 10 concentration levels per compound, and it greatly improves IC50/EC50 assay experimental productivity and data processing efficiency. © 2014 Society for Laboratory Automation and Screening.

  18. 30 CFR 57.22203 - Main fan operation (I-C mines).

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Main fan operation (I-C mines). 57.22203... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22203 Main fan operation (I-C mines). Main fans shall be operated continuously while ore production is in progress. ...

  19. Simultaneous detection of three lily viruses using Triplex IC-RT-PCR.

    Science.gov (United States)

    Zhang, Yubao; Wang, Yajun; Xie, Zhongkui; Yang, Guo; Guo, Zhihong; Wang, Le

    2017-11-01

    Viruses commonly infecting lily (Lilium spp.) include: Lily symptomless virus (LSV), Cucumber mosaic virus (CMV) and Lily mottle virus (LMoV). These viruses usually co-infect lilies causing severe economic losses in terms of quantity and quality of flower and bulb production around the world. Reliable and precise detection systems need to be developed for virus identification. We describe the development of a triplex immunocapture (IC) reverse transcription (RT) polymerase chain reaction (PCR) assay for the simultaneous detection of LSV, CMV and LMoV. The triplex IC-RT-PCR was compared with a quadruplex RT-PCR assay. Relative to the quadruplex RT-PCR, the specificity of the triplex IC-RT-PCR system for LSV, CMV and LMoV was 100% for field samples. The sensitivity of the triplex IC-RT-PCR system was 99.4%, 81.4% and 98.7% for LSV, CMV and LMoV, respectively. Agreement (κ) between the results obtained from the two tests was 0.968, 0.844 and 0.984 for LSV, CMV and LMoV, respectively. This is the first report of the simultaneous detection of LSV, CMV and LMoV in a triplex IC-RT-PCR assay. In particular we believe this convenient and reliable triplex IC-RT-PCR method could be used routinely for large-scale field surveys or crop health monitoring of lily. Copyright © 2017. Published by Elsevier B.V.

  20. Effects of a pre-operative home-based inspiratory muscle training programme on perceived health-related quality of life in patients undergoing coronary artery bypass graft surgery.

    Science.gov (United States)

    Valkenet, K; Trappenburg, J C A; Hulzebos, E H; van Meeteren, N L U; Backx, F J G

    2017-09-01

    Pre-operative inspiratory muscle training has been shown to decrease the incidence of postoperative pneumonia and length of hospital stay in patients undergoing coronary artery bypass graft surgery (CABG). This study investigated if this decrease acted as a mediator on the time course of quality of life. Complementary analyses of a published randomised controlled trial. The initial trial included patients awaiting CABG surgery at a Dutch university hospital. The secondary analyses used data from the initial trial for patients who had completed at least one quality-of-life questionnaire. Participants were allocated at random to the intervention group or the usual care group. The intervention group followed a home-based pre-operative inspiratory muscle training programme. Quality of life was measured at five time points. Between-group differences in quality-of-life scores were analysed using mixed linear modelling. The secondary analyses used data for 235 patients. In line with the initial trial, pneumonia and length of hospital stay were decreased significantly in the intervention group. The time courses for all patients showed significant improvements in quality of life after surgery compared with baseline. No significant differences in quality of life were observed over time between the two groups. Despite decreased incidence of pneumonia and length of hospital stay in the intervention group, this study did not find any improvements in quality of life due to the pre-operative home-based inspiratory muscle training programme. Clinical trial registration number ISRCTN17691887. Copyright © 2016 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  1. Postoperative Conversion Disorder Presenting as Inspiratory Stridor and Hemiparesis in a Pediatric Patient.

    Science.gov (United States)

    Nelson, Erik J; Wu, Jennifer Y

    2017-01-17

    BACKGROUND Postoperative conversion disorder is rare and has been reported. The diagnosis is usually made after all major organic causes have been ruled out. CASE REPORT We describe a case of a 13-year-old female who presented in the post-anesthesia care unit with acute-onset inspiratory stridor and unresponsiveness to verbal or painful stimuli after receiving a general anesthetic for upper endoscopy. Later in the post-anesthesia care unit, she presented with acute-onset right hemiplegia and sensory loss. She was first evaluated for causes of her stridor and unresponsiveness. The evaluation revealed paradoxical vocal cord movement, and all laboratory test values were normal. For her hemiplegia and sensory loss, she was evaluated for stroke with head MRI and CT scans, which were normal. CONCLUSIONS After extensive workup and consideration of multiple etiologies for her presenting signs and symptoms, the most likely diagnosis was conversion disorder.

  2. Generic test platform for representative tests of safety I/C systems - 15546

    International Nuclear Information System (INIS)

    Fourestie, B.; Kuck, H.; Richter, J.; Rieche, S.; Waitz, M.

    2015-01-01

    In compliance with the IEC 61513 safety Instrumentation and Control (I/C) systems must be successfully validated in their final configuration prior to installation on site and commissioning. However the contingent need for modifications during system validation activities or subsequently during the commissioning phase may entail long and costly re-engineering of the I/C systems. With the view to ease these possible modifications, a Generic Test Platform has been developed by AREVA which allows combining a real I/C system subpart with an emulation server. This platform provides a faithful representation of the I/C System allowing crediting the validation test results carried out on this platform. (authors)

  3. Inspiratory and expiratory HRCT findings in Behcet's disease and correlation with pulmonary function tests

    Energy Technology Data Exchange (ETDEWEB)

    Oezer, Caner [Department of Radiology, Mersin University, Faculty of Medicine, Mersin (Turkey)]. E-mail: cozer@mersin.edu.tr; Duce, Meltem Nass [Department of Radiology, Mersin University, Faculty of Medicine, Mersin (Turkey); Ulubas, Bahar [Department of Respiratory Disease, Mersin University, Faculty of Medicine, Mersin (Turkey); Bicer, Ali [Department of Physical Medicine and Rehabilitation, Mersin University, Faculty of Medicine, Mersin (Turkey); Tuersen, Uemit [Department of Dermatology, Mersin University, Faculty of Medicine, Mersin (Turkey); Apaydin, F. Demir [Department of Radiology, Mersin University, Faculty of Medicine, Mersin (Turkey); Yildiz, Altan [Department of Radiology, Mersin University, Faculty of Medicine, Mersin (Turkey); Camdeviren, Handan [Department of Biostatistics, Mersin University, Faculty of Medicine, Mersin (Turkey)

    2005-10-01

    Purpose: The purpose of our study was to describe the pulmonary parenchymal changes of Behcet's disease using high-resolution computed tomography and to correlate them with pulmonary function tests. Materials and methods: Thirty-four patients with Behcet's disease (18 men, 16 women), 3 of whom were symptomatic, were included as the study group. Four of 34 patients were smokers. Twenty asymptomatic volunteers (12 men, 8 women), 4 of whom were smokers, constituted the control group. The pulmonary function tests and high-resolution computed tomography were performed for both groups. Results: Inspiratory high-resolution computed tomography findings were abnormal in nine patients (26.5%) of the study group. In eight patients, there were multiple abnormalities, whereas one patient had only one abnormality. Pleural thickening and irregularities, major fissure thickening, emphysematous changes, bronchiectasis, parenchymal bands, and irregular densities, and parenchymal nodules were the encountered abnormalities. Inspiratory high-resolution computed tomography scans were normal in the control group. On expiratory scans, there was statistically significant difference between study group and control group when air trapping, especially grades 3 and 4, was compared (P < 0.01). Pulmonary function tests of both the study and the control groups were in normal ranges, and there was no statistically significant difference between the two groups according to pulmonary function tests (P > 0.05). Discussion and conclusion: High-resolution computed tomography is sensitive in the demonstration of pulmonary changes in patients with Behcet's disease. End-expiratory high-resolution computed tomography examination is very useful and necessary to show the presence of air trapping, thus the presence of small airway disease, even if the patient is asymptomatic or has normal pulmonary function tests.

  4. AGB stars as tracers to IC 1613 evolution.

    Science.gov (United States)

    Hashemi, S. A.; Javadi, A.; van Loon, J. Th.

    We are going to apply AGB stars to find star formation history for IC 1613 galaxy; this a new and simple method that works well for nearby galaxies. IC 1613 is a Local Group dwarf irregular galaxy that is located at distance of 750 kpc, a gas rich and isolated dwarf galaxy that has a low foreground extinction. We use the long period variable stars (LPVs) that represent the very final stage of evolution of stars with low and intermediate mass at the AGB phase and are very luminous and cool so that they emit maximum brightness in near-infrared bands. Thus near-infrared photometry with using stellar evolutionary models help us to convert brightness to birth mass and age and from this drive star formation history of the galaxy. We will use the luminosity distribution of the LPVs to reconstruct the star formation history-a method we have successfully applied in other Local Group galaxies. Our analysis shows that the IC 1613 has had a nearly constant star formation rate, without any dominant star formation episode.

  5. Incidence of tracheobronchomalacia associated with pulmonary emphysema. Detection with paired inspiratory-expiratory multidetector computed tomography using a low-dose technique

    International Nuclear Information System (INIS)

    Inoue, Masanori; Hasegawa, Ichiro; Nakano, Keiko; Yamaguchi, Kazuhiro; Kuribayashi, Sachio

    2009-01-01

    The purpose of this study was to evaluate the frequency of tracheobronchomalacia (TBM) associated with pulmonary emphysema with paired inspiratory-expiratory multidetector computed tomography (MDCT) using a low-dose technique. This study included 56 consecutive patients (55 men, 1 woman; mean age 68.9 years) with pulmonary emphysema who had undergone paired inspiratory-expiratory CT scanning with a low-dose technique (40 mA). All images were retrospectively examined by two thoracic radiologists in a blinded fashion. The diagnosis of TBM was based on the standard criterion of >50% reduction in the cross-sectional area of the tracheobronchial lumen at the end-expiratory phase. A mild TBM criterion of >30% reduction was also reviewed. All patients underwent pulmonary function tests. The relation between the forced expiratory volume in 1 s (FEV 1.0% ) and TBM was statistically analyzed. Four (7.1%) and eight (14.3%) patients were diagnosed as TBM based on the standard and mild criteria, respectively. In four patients, the percentages of luminal narrowing were 63.4% and 51.2%, respectively for tracheomalacia and 59.2% and 62.0%, respectively, for bronchomalacia. The FEV 1.0% values between patients with and without TBM showed no statistical difference. The incidence of TBM associated with pulmonary emphysema was 7.1% with the standard criterion. It is possible that TBM has been underdiagnosed in a number of patients with pulmonary emphysema. (author)

  6. Prediction of fracture toughness K/sub Ic/ of steel from Charpy impact test results

    Energy Technology Data Exchange (ETDEWEB)

    Iwadate, Tadao; Tanaka, Yasuhiko; Takemata, Hiroyuki; Terashima, Shuhei

    1986-08-01

    This paper presents a method to predict the fracture toughness K/sub Ic/ and/or K/sub Id/ of steels using their Charpy impact test results and tensile properties. The fracture toughness, Charpy impact and tensile properties of 2 1/4 Cr-1Mo, ASTM A508 Cl.1, A508 Cl.2 A508 Cl.3 and A533 Gr.B Cl.1 steels were measured and analysed on the basis of the excess temperature (test temperature minus FATT) and Rolfe-Novak correlation. The relationship between K/sub Ic//K/sub Ic-us/ and the excess temperature, where K/sub Ic-us/ is the upper-shelf fracture toughness K/sub Ic/ predicted by Rolfe-Novak correlation, discloses that the K/sub Ic/ transition curves of several steels are representable by only one trend curve of K/sub Ic//K/sub Ic-us/ or K/sub Id//K/sub Id-us/ versus excess temperature relation. This curve is denoted as a ''master curve''. By using this curve, the fracture toughness of steel can be predicted using Charpy impact and tensile test results. By taking account of the scattering of both the fracture toughness and Charpy impact test results, the confidence limits of the master curve were also determined. Another approach to develop more general procedure of predicting the fracture toughness K/sub Ic/ is also discussed.

  7. Industry-Oriented Laboratory Development for Mixed-Signal IC Test Education

    Science.gov (United States)

    Hu, J.; Haffner, M.; Yoder, S.; Scott, M.; Reehal, G.; Ismail, M.

    2010-01-01

    The semiconductor industry is lacking qualified integrated circuit (IC) test engineers to serve in the field of mixed-signal electronics. The absence of mixed-signal IC test education at the collegiate level is cited as one of the main sources for this problem. In response to this situation, the Department of Electrical and Computer Engineering at…

  8. 30 CFR 57.22241 - Advance face boreholes (I-C mines).

    Science.gov (United States)

    2010-07-01

    ...) Boreholes shall be drilled in such a manner to insure that the advancing face will not accidently break into... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Advance face boreholes (I-C mines). 57.22241... Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22241 Advance face boreholes (I-C mines...

  9. Quantitative assessment of cross-sectional area of small pulmonary vessels in patients with COPD using inspiratory and expiratory MDCT

    International Nuclear Information System (INIS)

    Matsuura, Yukiko; Kawata, Naoko; Yanagawa, Noriyuki; Sugiura, Toshihiko; Sakurai, Yoriko; Sato, Misuzu; Iesato, Ken; Terada, Jiro; Sakao, Seiichiro; Tada, Yuji; Tanabe, Nobuhiro; Suzuki, Yoichi; Tatsumi, Koichiro

    2013-01-01

    Objectives: Structural and functional changes in pulmonary vessels are prevalent at the initial stages of chronic obstructive pulmonary disease (COPD). These vascular alterations can be assessed using cross-sectional area (CSA) of small pulmonary vessels. However, neither in non-COPD smokers nor in COPD patients it has been defined whether the structural changes of pulmonary vessels detected by paired inspiratory and expiratory CT scans are associated with emphysematous changes. We quantified the CSA and low attenuation area (LAA) and evaluated the changes in these parameters in the inspiratory and expiratory phases. Materials and methods: Fifty consecutive non-COPD smokers and COPD patients were subjected to multi detector-row CT and the percentage of vessels with a CSA less than 5 mm 2 as well as the percentage LAA for total lung area (%CSA < 5, %LAA, respectively) were calculated. Results: The %CSA < 5 correlated negatively with %LAA. The %CSA < 5 was lower in COPD patients with emphysema as compared with non-COPD smokers and COPD patients with or without mild emphysema. In addition, the %CSA < 5 was lower in the no/mild emphysema subgroup as compared with non-COPD smokers. The respiratory phase change of %CSA < 5 in COPD patients was greater than that in non-COPD smokers. Conclusion: The percentage of small pulmonary vessels decreased as emphysematous changes increase, and this decrease was observed even in patients with no/mild emphysema. Furthermore, respiratory phase changes in CSA were higher in COPD patients than in non-COPD smokers

  10. Synthesis of novel octyl sinapate to enhance antioxidant capacity of rapeseed-linseed oil mixture.

    Science.gov (United States)

    Szydłowska-Czerniak, Aleksandra; Rabiej, Dobrochna; Krzemiński, Marek

    2018-03-01

    Lipophilisation allows the formation of new functionalised antioxidants having beneficial properties compared to natural hydrophilic phenolic acids. Therefore, this work focused on the synthesis of lipophilic antioxidants, such as a new octyl sinapate, octyl caffeate and octyl ferulate using the modified Fischer esterification of selected hydroxycinnamic acids with 1-octanol. The lipophilic octyl sinapate was obtained for the first time with satisfactory yield (83%) after purification by column chromatography. The identity of the synthesised phenolipids was confirmed by chromatographic and spectroscopic analyses. Antioxidant capacity of phenolipids was determined by DPPH (IC 50  = 35.87-52.24 μg mL -1 ) and ABTS (IC 50  = 39.45-48.72 μg mL -1 ) methods and compared with IC 50 values (7.37-35.30 μg mL -1 and 7.55-41.67 μg mL -1 , respectively) for well known antioxidants. The antioxidant capacity of rapeseed-linseed oil enriched with the purified esters was about two to 30 times higher in comparison with a non-supplemented oil. The novel octyl sinapate as well as octyl caffeate and octyl ferulate have antioxidant properties and lipophilic character, therefore they may be added to vegetable oils as potential antioxidants for tackling oxidative processes. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  11. PENGARUH MEKANISME CORPORATE GOVERNANCE TERHADAP PENGUNGKAPAN INTELLECTUAL CAPITAL: PADA PERUSAHAAN IC INTENSIVE

    Directory of Open Access Journals (Sweden)

    Dista Amalia Arifah

    2012-12-01

    Full Text Available Intangible asset proxied by Intellectual Capital has important role to drive companies values creation. Although many companies have applied corporate governance mechanism in order to have IC disclosure recognition, most of them do not focus on Intellectual Capital disclosure yet. The aim of this study is to analyze the influence of corporate governance mechanisms consisting of size of the board commissioners, the independence level of independent commissioner, the activities of independent commissioners, and audit committee on the intellectual capital disclosures of the companies listed in BEI in 2009 using intensive ICs category with the adding of kontrol variables. This study will provide an illustration on how the mechanisms of corporate governance practices and IC disclosure become a value creation source for the company. There are a total of 176 companies categorized as IC intensive. Using a purposive sampling method, 45 companies were selected as samples. The 2009 annual reports of the companies are used as secondary data source of this research. Furthermore, to get ICs disclosure data content analysis technique was used both for quantity and quality terms. The results indicate that audit committee is the only corporate governance mechanism that significantly affects the level of IC disclosures.

  12. Positioning of electrode plane systematically influences EIT imaging

    International Nuclear Information System (INIS)

    Krueger-Ziolek, Sabine; Schullcke, Benjamin; Kretschmer, Jörn; Möller, Knut; Zhao, Zhanqi; Müller-Lisse, Ullrich

    2015-01-01

    Up to now, the impact of electrode positioning on electrical impedance tomography (EIT) had not been systematically analyzed due to the lack of a reference method. The aim of the study was to determine the impact of electrode positioning on EIT imaging in spontaneously breathing subjects at different ventilation levels with our novel lung function measurement setup combining EIT and body plethysmography. EIT measurements were conducted in three transverse planes between the 3rd and 4th intercostal space (ICS), at the 5th ICS and between the 6th and 7th ICS (named as cranial, middle and caudal) on 12 healthy subjects. Pulmonary function tests were performed simultaneously by body plethysmography to determine functional residual capacity (FRC), vital capacity (VC), tidal volume (VT), expiratory reserve volume (ERV), and inspiratory reserve volume (IRV). Ratios of impedance changes and body plethysmographic volumes were calculated for every thorax plane (ΔI_E_R_V/ERV, ΔI_V_T/VT and ΔI_I_R_V/IRV). In all measurements of a subject, FRC values and VC values differed ≤5%, which confirmed that subjects were breathing at comparable end-expiratory levels and with similar efforts. In the cranial thorax plane the normalized ΔI_E_R_V/ERV ratio in all subjects was significantly higher than the normalized ΔI_I_R_V/IRV ratio whereas the opposite was found in the caudal chest plane. No significant difference between the two normalized ratios was found in the middle thoracic plane. Depending on electrode positioning, impedance to volume ratios may either increase or decrease in the same lung condition, which may lead to opposite clinical decisions. (paper)

  13. Dead-time free pixel readout architecture for ATLAS front-end IC

    CERN Document Server

    Einsweiler, Kevin F; Kleinfelder, S A; Luo, L; Marchesini, R; Milgrome, O; Pengg, F X

    1999-01-01

    A low power sparse scan readout architecture has been developed for the ATLAS pixel front-end IC. The architecture supports a dual discriminator and extracts the time over threshold (TOT) information along with a 2-D spatial address $9 of the hits associating them with a unique 7-bit beam crossing number. The IC implements level-1 trigger filtering along with event building (grouping together all hits in a beam crossing) in the end of column (EOC) buffer. The $9 events are transmitted over a 40 MHz serial data link with the protocol supporting buffer overflow handling by appending error flags to events. This mixed-mode full custom IC is implemented in 0.8 mu HP process to meet the $9 requirements for the pixel readout in the ATLAS inner detector. The circuits have been tested and the IC provides dead-time-less ambiguity free readout at 40 MHz data rate.

  14. Is serial determination of inspiratory muscle strength a useful prognostic marker in chronic heart failure?

    Science.gov (United States)

    Frankenstein, Lutz; Meyer, Franz Joachim; Sigg, Caroline; Nelles, Manfred; Schellberg, Dieter; Remppis, Andrew; Katus, Hugo A; Zugck, Christian

    2008-04-01

    Little data exists on the prognostic role of inspiratory muscle strength (PImax) in chronic heart failure (CHF). Training studies, however, frequently use it as a therapeutic target and surrogate marker for prognosis. The prognostic value of changes of PImax that allow this extrapolation is unknown. Patients with stable CHF were prospectively included and 1-year and all-time event rates recorded for endpoint analysis. In 158 patients (85% men; New York Heart Association functional class: 2.4+/-0.6), PImax was measured along with clinical evaluations at two visits, the initial visit and the second visit, 6.4+/-1.4 months apart. The mean follow-up was 59+/-34 months. Overall, 59 patients (37%) reached the primary endpoint of death or hospitalization (endpoint positive), and overall mortality rate (secondary endpoint) was 26% (42 patients). PImax did not differ between endpoint-negative and endpoint-positive patients, both at the initial and at the second visit (8.3+/-5.6 vs. 7.3+/-3.4 kPa and 8.8+/-6.0 vs. 7.9+/-3.6 kPa, respectively; P=NS), and both groups showed increased PImax (0.6+/-2.6 vs. 0.6+/-2.8 kPa; P=NS). Cox analyses found neither the absolute nor the relative change of PImax to be significant predictors for the primary and secondary endpoints (P=NS for both), both for the 1-year and for the all-time event rates. Endpoint rates did not differ between patients showing increasing or decreasing PImax (P=NS; relative risk (RR): 0.77; 95% confidence interval: 0.47-1.27). Trials focusing on inspiratory muscle function should use the actual levels of PImax as a surrogate marker to represent prognostic information, rather than relative or absolute changes. This is the first study to investigate the prognostic information of the changes of PImax over time, regarding both short-term and long-term morbidity and mortality in patients with stable CHF.

  15. Evaluation of oxidative stress status and antioxidant capacity in patients with painful bladder syndrome/interstitial cystitis: preliminary results of a randomised study.

    Science.gov (United States)

    Ener, Kemal; Keske, Murat; Aldemir, Mustafa; Özcan, Muhammet Fuat; Okulu, Emrah; Özayar, Asım; Ergin, Merve; Doluoğlu, Ömer Gökhan; Çakmak, Serdar; Erel, Özcan

    2015-08-01

    This study aimed to investigate oxidative stress in etiopathogenesis by analyzing serum total antioxidant capacity (TAC), total oxidant status (TOS), binding capacity of exogenous cobalt to human albumin (IMA), serum advanced oxidation protein products (AOPP), paraoxonase (PON), arylesterase, IgE, and C-reactive protein (CRP) in bladder pain syndrome/interstitial cystitis (BPS/IC). The study included 16 female patients diagnosed with BPS/IC and 25 healthy female subjects forming the control group. A bladder biopsy was performed on all patients in the BPS/IC group by carrying out cystoscopy with hydrodistention under general anesthesia. The results of serum TAC, TOS, IMA, AOPP, PON, arylesterase, IgE, and CRP of the subjects in both groups were compared. The mean age of the 16 female patients in the BPS/IC group was 43.6 ± 14.5 years, and the mean age of the 25 healthy subjects in the control group was 42.0 ± 10.3 years. According to the criteria of International Society for the Study of Interstitial Cystitis (ESSIC), eight patients were classified as Type 2A, three patients as Type 2B, four patients as Type 2C, and one patient as Type 3C. In the BPS/IC group, while TAC was found significantly lower than in the control group, IMA, IgE, and CRP were found significantly higher (P < 0.05). When binary logistic regression analysis was performed, the created model was determined to have 81.3 % sensitivity and 80 % specifity. In the etiology of BPS/IC, mechanism of oxidative damage comes into prominence. In the diagnosis of BPS/IC, IgE, CRP, and TAC are not specific markers when used separately; however, a higher specifity and sensitivity could be reached when used jointly in the suspected patients.

  16. Evaluation of image quality and patient safety: paired inspiratory and expiratory MDCT assessment of tracheobronchomalacia in paediatric patients under general anaesthesia with breath-hold technique

    International Nuclear Information System (INIS)

    Lee, Edward Y.; Bastos, Maria d' Almeida; Stark, Cynthia; Carrier, Maureen; Zurakowski, David; Mason, Keira P.

    2012-01-01

    The purpose of our investigation was to evaluate image quality and patient safety in infants and young children who required general anaesthesia with breath-hold technique for paired inspiratory and expiratory multidetector CT (MDCT) assessment of tracheobronchomalacia (TBM). Our hospital's institutional review board approved the review of radiological and clinical data of a consecutive series of 20 paediatric patients who underwent MDCT under general anaesthesia with breath-hold technique for evaluation of TBM from May 2006 to December 2008. For each MDCT study, two fellowship-trained paediatric radiologists reviewed the inspiratory and expiratory MDCT images in an independent, randomised and blinded fashion for the presence of motion artefact at three anatomic levels (upper, middle and lower central airways). The clinical history and anaesthesia outcome, including the occurrence of any adverse events during or following the MDCT examinations until discharge, were also reviewed and recorded. The study population consisted of 20 infants and young children (13 boys/seven girls, mean age 1.7 ± 1.4 years, age range 11 days to 4 years). The imaging quality of all 20 MDCT studies was diagnostic with no motion artefact in 16 studies (80%) and minimal motion artefact in the remaining four studies (20%). Minor adverse events occurred in three patients (15%) that included one patient (5%) with a brief (<60 s) oxygen desaturation during MDCT study, which resolved with oxygen, and two patients (5%) with either a brief (<60 s) oxygen desaturation (n = 1, 5%) or cough (n = 1, 5%) during recovery period, which were completely resolved with oxygen and dexamethasone, respectively. Diagnostic quality paired inspiratory and expiratory MDCT imaging with breath-hold technique can be safely performed in infants and young children under general anaesthesia for evaluation of TBM.

  17. Development of an ASD IC for the Micro Pixel Chamber

    CERN Document Server

    Orito, R; Kubo, H; Miuchi, K; Nagayoshi, T; Okada, Y; Takada, A; Takeda, A; Tanimori, T; Ueno, M

    2004-01-01

    A new amplifier-shaper-discriminator (ASD) chip was designed and manufactured for the Micro Pixel Chamber ($\\mu$-PIC). The design of this ASD IC is based on the ASD IC (TGC-ASD) for the Thin Gap Chamber in the LHC Atlas Experiment. The decay time constant of the preamplifier is 5-times longer than that of the TGC-ASD, and some other modifications have been made in order to improve the signal-to-noise ratio of the $\\mu$-PIC. The ASD IC uses SONY Analog Master Slice bipolar technology. The IC contains 4 channels in a QFP48 package. The decay time constant of the preamplifier is 80 ns and its gain is approximately 0.8 V/pC. The output from the preamplifier is received by a shaper (main-amplifier) with a gain of 7. A baseline restoration circuit is incorporated in the main-amplifier, and the current used for the baseline restoration is 5-times smaller than that of the TGC-ASD. The threshold voltage for the discriminator section is common to the 4 channels and their digital output level is LVDS-compatible. The ASD...

  18. The integrated circuit IC EMP transient state disturbance effect experiment method investigates

    International Nuclear Information System (INIS)

    Li Xiaowei

    2004-01-01

    Transient state disturbance characteristic study on the integrated circuit, IC, need from its coupling path outset. Through cable (aerial) coupling, EMP converts to an pulse current voltage and results in the impact to the integrated circuit I/O orifice passing the cable. Aiming at the armament system construction feature, EMP effect to the integrated circuit, IC inside the system is analyzed. The integrated circuit, IC EMP effect experiment current injection method is investigated and a few experiments method is given. (authors)

  19. State-of-health monitoring of lithium-ion battery modules and packs via incremental capacity peak tracking

    International Nuclear Information System (INIS)

    Weng, Caihao; Feng, Xuning; Sun, Jing; Peng, Huei

    2016-01-01

    Highlights: • A new framework based on ICA is used to monitor SOH on-board for battery packs. • The applicability of the framework is validated through simulation and experiment. • The method can monitor SOH for pack consisting of cells with various aging paths. • On-board incremental capacity analysis is realized by support vector regression. - Abstract: Incremental capacity analysis (ICA) is a widely used technique for lithium-ion battery state-of-health (SOH) evaluation. The effectiveness and robustness of ICA for single cell diagnostics have been reported in many published work. In this study, we extend the ICA based SOH monitoring approach from single cells to battery modules, which consist of battery cells with various aging conditions. In order to achieve on-board implementation, an IC peak tracking approach based on the ICA principles is proposed. Analytical, numerical and experimental results are presented to demonstrate the utility of the IC peak tracking framework on multi-cell battery SOH monitoring and the effects of cell non-uniformity on the proposed method. Results show that the methods developed for single cell capacity estimation can also be used for a module or pack that has parallel-connected cells.

  20. Use of advanced commercial ICs (COTS) for space application

    International Nuclear Information System (INIS)

    Strobel, D.J.; Czajkowski, D.R.; Layton, P.; Shanken, S.

    1999-01-01

    A product line of space-qualified radiation-tolerant ICs based on a high-volume commercial-off-the-shelf (COTS) silicon has been developed. The basic results from over 300 lots of COTS silicon, assembled and screened to Class B and Class S requirements will be presented. Intelligent use of commercial ICs engineered to improve radiation performance, is effective in introducing advanced technology to new satellite systems. Space Electronics has introduced over 125 space-qualified microelectronics standard products, that are used on over 90 space projects. (authors)

  1. Moving from irrelevant intellectual capital (IC) reporting to value-relevant IC disclosures: key learning points from the Danish experience

    DEFF Research Database (Denmark)

    Schaper, Stefan; Nielsen, Christian; Roslender, Robin

    2017-01-01

    , largely informed by an accounting perspective, towards IC-related disclosures. Design/methodology/approach – The paper draws on data obtained from 21 semi-structured interviews with respondents in 16 companies. The respondents were contacted following a genealogical exercise carried out on the 102...... with a recognised reporting vehicle such as the annual report, were also encountered. Research limitations/implications – The implications of this study are that timely, value-relevant IC disclosures and compliant reporting, primarily for accountability purposes, have the potential to coexist. In addition...... to the usual limitations of a semi-structured interview research design, respondents’ difficulties in clearly recalling events during the project after some 10-12 years is a further potential limitation. Additionally, the use of internet-based communication channels for disclosure purposes was in its infancy...

  2. Immediate effect of suryanadi pranayama on pulmonary function (ventilatory volumes and capacities in healthy volunteers

    Directory of Open Access Journals (Sweden)

    Shravya Keerthi G, Hari Krishna Bandi, Suresh M, Mallikarjuna Reddy N

    2013-10-01

    Full Text Available Objectives: we found only effects of at least a short term practice extended over a period of a few days to weeks of pranayama (alternate nostril breathing rather than acute effects of unilateral right nostril breathing (suryanadi pranayama. Keeping this in mind the present study was designed to test the hypothesis that 10 min. of right nostril breathing have any immediate effect on ventilatory volumes and capacities in healthy volunteers. Methodology: Forced vital capacity (FVC, Forced expiratory volume in the first second (FEV1, Forced expiratory volume percent (FEV1/FVC%, Peak expiratory flow rate (PEFR, Forced expiratory flow25-75% (FEF25-75%, Maximum voluntary ventilation (MVV, Slow vital capacity (SVC, Expiratory reserve volume (ERV, Inspiratory reserve volume (IRV and Tidal volume (TV were recorded before and after Surya Nadi Pranayama. Results & Conclusion: There was a significant increase in FVC (p<0.0001, FEV1 (p<0.0007, PEFR (p<0.0001, FEF25-75% (p<0.0001, MVV (p<0.0001, SVC (p<0.0001, ERV (0.0006, IRV (p<0.0001 and TV (0.0055 after suryanadi pranayama. The immediate effect of suryanadi pranayama practice showed alleviation of ventilatory capacities and volumes. Any practice that increases PEFR and FEF25–75% is expected to retard the development of COPD’s. The increase in PEFR, vital capacities and flow rates by suryanadi pranayama practice obviously offers an increment in respiratory efficiency and it can be advocated to the patients of early bronchitis and as a preventive measure for COPD.

  3. Innovative Teaching of IC Design and Manufacture Using the Superchip Platform

    Science.gov (United States)

    Wilson, P. R.; Wilcock, R.; McNally, I.; Swabey, M.

    2010-01-01

    This paper describes how an intelligent chip architecture has allowed a large cohort of undergraduate (UG) students to be given effective practical insight into integrated circuit (IC) design by designing and manufacturing their own ICs. To achieve this, an efficient chip architecture, the "Superchip," was developed, which allows multiple student…

  4. Purification, crystallization and preliminary X-ray analysis of aminoglycoside-2′′-phosphotransferase-Ic [APH(2′′)-Ic] from Enterococcus gallinarum

    International Nuclear Information System (INIS)

    Byrnes, Laura J.; Badarau, Adriana; Vakulenko, Sergei B.; Smith, Clyde A.

    2008-01-01

    APH(2′′)-Ic is an enzyme that is responsible for high-level gentamicin resistance in E. gallinarum isolates. Crystals of the wild-type enzyme and three mutants have been prepared and a complete X-ray diffraction data set was collected to 2.15 Å resolution from an F108L crystal. Bacterial resistance to aminoglycoside antibiotics is primarily the result of deactivation of the drugs. Three families of enzymes are responsible for this activity, with one such family being the aminoglycoside phosphotransferases (APHs). The gene encoding one of these enzymes, aminoglycoside-2′′-phosphotransferase-Ic [APH(2′′)-Ic] from Enterococcus gallinarum, has been cloned and the wild-type protein (comprising 308 amino-acid residues) and three mutants that showed elevated minimum inhibitory concentrations towards gentamicin (F108L, H258L and a double mutant F108L/H258L) were expressed in Escherichia coli and subsequently purified. All APH(2′′)-Ic variants were crystallized in the presence of 14–20%(w/v) PEG 4000, 0.25 M MgCl 2 , 0.1 M Tris–HCl pH 8.5 and 1 mM Mg 2 GTP. The crystals belong to the monoclinic space group C2, with one molecule in the asymmetric unit. The approximate unit-cell parameters are a = 82.4, b = 54.2, c = 77.0 Å, β = 108.8°. X-ray diffraction data were collected to approximately 2.15 Å resolution from an F108L crystal at beamline BL9-2 at SSRL, Stanford, California, USA

  5. Diagnostic accuracy of metronome-paced tachypnea to detect dynamic hyperinflation.

    Science.gov (United States)

    Lahaije, Anke J M C; Willems, Laura M; van Hees, Hieronymus W H; Dekhuijzen, P N Richard; van Helvoort, Hanneke A C; Heijdra, Yvonne F

    2013-01-01

    This prospective study was carried out to investigate if metronome-paced tachypnea (MPT) can serve as an accurate diagnostic tool to identify patients with chronic obstructive pulmonary disease (COPD) who are susceptible to develop dynamic hyperinflation during exercise. Commonly, this is assessed by measuring change in inspiratory capacity (IC) during cardiopulmonary exercise testing (CPET), which, however, is complex and laborious. Fifty-three patients with COPD (FEV(1) 58 ± 22%pred) and 20 age-matched healthy subjects were characterized by lung function testing and performed CPET (reference standard) and MPT. The repeatability coefficient of IC (10·2%) was used as cut-off to classify subjects as hyperinflators during CPET. Subsequently, dynamic hyperinflation was measured after MPT. With receiver operating characteristic analysis, the optimal cut-off for MPT-induced dynamic hyperinflation was determined and sensitivity and specificity of MPT to identify hyperinflators were evaluated. With 10·2% decrease in IC as cut-off for CPET-induced dynamic hyperinflation, the optimal cut-off for MPT was 11·1% decrease in IC. Using these cut-offs, MPT had a sensitivity of 85% and specificity of 85% to identify the subjects who hyperinflated during CPET. The MPT test shows good overall accuracy to identify subjects who are susceptible to develop dynamic hyperinflation during CPET. Before considering the use of MPT as a screening tool for dynamic hyperinflation in COPD, sensitivity and specificity need further evaluation. © 2012 The Authors Clinical Physiology and Functional Imaging © 2012 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

  6. Transient SEU characterization of analog IC's for ESA's satellite

    International Nuclear Information System (INIS)

    Harboe-Soerensen, R.; Van Dooren, J.; Guerre, F.X.; Constans, H.; Berger, G.; Hajdas, W.

    1999-01-01

    Data analysis of four self switch-off power supply events in the SOHO satellite pointed strongly in the direction of being Cosmic Ray or Proton induced. Further analysis of the relevant power supply schematics identified a number of analog IC's capable of causing or contributing to such events. This paper concentrates on the testing aspects of these analog IC's and presents the results of a Single Event Effects (SEEs) test program. Ground testing, simulating the flight conditions, were carried out at both heavy ion and proton accelerators. (authors)

  7. Effects of inspiratory muscle exercise in the pulmonary function, autonomic modulation, and hemodynamic variables in older women with metabolic syndrome

    Science.gov (United States)

    Feriani, Daniele Jardim; Coelho, Hélio José; Scapini, Kátia Bilhar; de Moraes, Oscar Albuquerque; Mostarda, Cristiano; Ruberti, Olivia Moraes; Uchida, Marco Carlos; Caperuto, Érico Chagas; Irigoyen, Maria Cláudia; Rodrigues, Bruno

    2017-01-01

    The aim of the present study was to investigate the effects of inspiratory muscle exercise (IME) on metabolic and hemodynamic parameters, cardiac autonomic modulation and respiratory function of older women with metabolic syndrome (MS). For this, sixteen older women with MS and 12 aged-matched controls participated of the present study. Two days before and 2 days after the main experiment, fasting blood samples (i.e., total cholesterol, triglycerides and blood glucose), cardiac autonomic modulation (i.e., heart rate variability), and respiratory muscle function were obtained and evaluated. The sessions of physical exercise was based on a IME, which was performed during 7 days. Each session of IME was performed during 20 min, at 30% of maximal static inspiratory pressure. In the results, MS group presented higher levels of triglycerides, blood glucose, and systolic blood pressure when compared to control group. IME was not able to change these variables. However, although MS group showed impaired respiratory muscle strength and function, as well as cardiac autonomic modulation, IME was able to improve these parameters. Thus, the data showed that seven days of IME are capable to improve respiratory function and cardiac autonomic modulation of older women with MS. These results indicate that IME can be a profitable therapy to counteracting the clinical markers of MS, once repeated sessions of acute IME can cause chronical alterations on respiratory function and cardiac autonomic modulation. PMID:28503537

  8. Classification of fMRI independent components using IC-fingerprints and support vector machine classifiers.

    Science.gov (United States)

    De Martino, Federico; Gentile, Francesco; Esposito, Fabrizio; Balsi, Marco; Di Salle, Francesco; Goebel, Rainer; Formisano, Elia

    2007-01-01

    We present a general method for the classification of independent components (ICs) extracted from functional MRI (fMRI) data sets. The method consists of two steps. In the first step, each fMRI-IC is associated with an IC-fingerprint, i.e., a representation of the component in a multidimensional space of parameters. These parameters are post hoc estimates of global properties of the ICs and are largely independent of a specific experimental design and stimulus timing. In the second step a machine learning algorithm automatically separates the IC-fingerprints into six general classes after preliminary training performed on a small subset of expert-labeled components. We illustrate this approach in a multisubject fMRI study employing visual structure-from-motion stimuli encoding faces and control random shapes. We show that: (1) IC-fingerprints are a valuable tool for the inspection, characterization and selection of fMRI-ICs and (2) automatic classifications of fMRI-ICs in new subjects present a high correspondence with those obtained by expert visual inspection of the components. Importantly, our classification procedure highlights several neurophysiologically interesting processes. The most intriguing of which is reflected, with high intra- and inter-subject reproducibility, in one IC exhibiting a transiently task-related activation in the 'face' region of the primary sensorimotor cortex. This suggests that in addition to or as part of the mirror system, somatotopic regions of the sensorimotor cortex are involved in disambiguating the perception of a moving body part. Finally, we show that the same classification algorithm can be successfully applied, without re-training, to fMRI collected using acquisition parameters, stimulation modality and timing considerably different from those used for training.

  9. Quantitative assessment of cross-sectional area of small pulmonary vessels in patients with COPD using inspiratory and expiratory MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Matsuura, Yukiko, E-mail: matsuyuki_future@yahoo.co.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Kawata, Naoko, E-mail: chumito_03@yahoo.co.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Yanagawa, Noriyuki, E-mail: yanagawa@ho.chiba-u.ac.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Sugiura, Toshihiko, E-mail: sugiura@js3.so-net.ne.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Sakurai, Yoriko, E-mail: yoliri@nifty.com [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Sato, Misuzu, E-mail: mis_misuzu@yahoo.co.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Iesato, Ken, E-mail: iesato_k@yahoo.co.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Terada, Jiro, E-mail: jirotera@chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Sakao, Seiichiro, E-mail: sakao@faculty.chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Tada, Yuji, E-mail: ytada@faculty.chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Tanabe, Nobuhiro, E-mail: ntanabe@faculty.chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Suzuki, Yoichi, E-mail: ysuzuki@faculty.chiba-u.jp [Department of public Health, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Tatsumi, Koichiro, E-mail: tatsumi@faculty.chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan)

    2013-10-01

    Objectives: Structural and functional changes in pulmonary vessels are prevalent at the initial stages of chronic obstructive pulmonary disease (COPD). These vascular alterations can be assessed using cross-sectional area (CSA) of small pulmonary vessels. However, neither in non-COPD smokers nor in COPD patients it has been defined whether the structural changes of pulmonary vessels detected by paired inspiratory and expiratory CT scans are associated with emphysematous changes. We quantified the CSA and low attenuation area (LAA) and evaluated the changes in these parameters in the inspiratory and expiratory phases. Materials and methods: Fifty consecutive non-COPD smokers and COPD patients were subjected to multi detector-row CT and the percentage of vessels with a CSA less than 5 mm{sup 2} as well as the percentage LAA for total lung area (%CSA < 5, %LAA, respectively) were calculated. Results: The %CSA < 5 correlated negatively with %LAA. The %CSA < 5 was lower in COPD patients with emphysema as compared with non-COPD smokers and COPD patients with or without mild emphysema. In addition, the %CSA < 5 was lower in the no/mild emphysema subgroup as compared with non-COPD smokers. The respiratory phase change of %CSA < 5 in COPD patients was greater than that in non-COPD smokers. Conclusion: The percentage of small pulmonary vessels decreased as emphysematous changes increase, and this decrease was observed even in patients with no/mild emphysema. Furthermore, respiratory phase changes in CSA were higher in COPD patients than in non-COPD smokers.

  10. Studying Radiation Tolerant ICs for LHC

    CERN Multimedia

    Faccio, F; Snoeys, W; Campbell, M; Casas-cubillos, J; Gomes, P

    2002-01-01

    %title\\\\ \\\\In the recent years, intensive work has been carried out on the development of custom ICs for the readout electronics for LHC experiments. As far as radiation hardness is concerned, attention has been focussed on high total dose applications, mainly for the tracker systems. The dose foreseen in this inner region is estimated to be higher than 1~Mrad/year. In the framework of R&D projects (RD-9 and RD-20) and in the ATLAS and CMS experiments, the study of different radiation hard processes has been pursued and good contacts with the manufacturers have been established. The results of these studies have been discussed during the Microelectronics User Group (MUG) rad-hard meetings, and now some HEP groups are working to develop radiation hard ICs for the LHC experiments on some of the available rad-hard processes.\\\\ \\\\In addition, a lot of the standard commercial electronic components and ASICs which are planned to be installed near the LHC machine and in the detectors will receive total doses in ...

  11. Mathematical and Simulation Modelling of Moisture Diffusion Mechanism during Plastic IC Packages Disassembly

    OpenAIRE

    Peng Mou; Dong Xiang; Guanghong Duan

    2013-01-01

    Reuse of plastic IC packages disassembled from printed circuit boards (PCBs) has significant environmental benefits and economic value. The interface delamination caused by moisture diffusion is the main failure mode of IC packages during the disassembling process, which greatly reduces the reusability and reliability of disassembled IC packages. Exploring moisture diffusion mechanism is a prerequisite to optimize prebaking processes before disassembling that is an effective way to avoid the ...

  12. SUPER-LUMINOUS TYPE Ic SUPERNOVAE: CATCHING A MAGNETAR BY THE TAIL

    International Nuclear Information System (INIS)

    Inserra, C.; Smartt, S. J.; Jerkstrand, A.; Fraser, M.; Wright, D.; Smith, K.; Chen, T.-W.; Kotak, R.; Nicholl, M.; Valenti, S.; Pastorello, A.; Benetti, S.; Bresolin, F.; Kudritzki, R. P.; Burgett, W. S.; Chambers, K. C.; Flewelling, H.; Botticella, M. T.; Ergon, M.; Fynbo, J. P. U.

    2013-01-01

    We report extensive observational data for five of the lowest redshift Super-Luminous Type Ic Supernovae (SL-SNe Ic) discovered to date, namely, PTF10hgi, SN2011ke, PTF11rks, SN2011kf, and SN2012il. Photometric imaging of the transients at +50 to +230 days after peak combined with host galaxy subtraction reveals a luminous tail phase for four of these SL-SNe. A high-resolution, optical, and near-infrared spectrum from xshooter provides detection of a broad He I λ10830 emission line in the spectrum (+50 days) of SN2012il, revealing that at least some SL-SNe Ic are not completely helium-free. At first sight, the tail luminosity decline rates that we measure are consistent with the radioactive decay of 56 Co, and would require 1-4 M ☉ of 56 Ni to produce the luminosity. These 56 Ni masses cannot be made consistent with the short diffusion times at peak, and indeed are insufficient to power the peak luminosity. We instead favor energy deposition by newborn magnetars as the power source for these objects. A semi-analytical diffusion model with energy input from the spin-down of a magnetar reproduces the extensive light curve data well. The model predictions of ejecta velocities and temperatures which are required are in reasonable agreement with those determined from our observations. We derive magnetar energies of 0.4 ∼ 51 erg) ∼ ej (M ☉ ) ∼< 8.6. The sample of five SL-SNe Ic presented here, combined with SN 2010gx—the best sampled SL-SNe Ic so far—points toward an explosion driven by a magnetar as a viable explanation for all SL-SNe Ic.

  13. Recognition of battery aging variations for LiFePO4 batteries in 2nd use applications combining incremental capacity analysis and statistical approaches

    Science.gov (United States)

    Jiang, Yan; Jiang, Jiuchun; Zhang, Caiping; Zhang, Weige; Gao, Yang; Guo, Qipei

    2017-08-01

    To assess the economic benefits of battery reuse, the consistency and aging characteristics of a retired LiFePO4 battery pack are studied in this paper. The consistency of battery modules is analyzed from the perspective of the capacity and the internal resistance. Test results indicate that battery module parameter dispersion increases along with battery aging. However, battery modules with better capacity consistency doesn't ensure better resistance consistency. Then the aging characteristics of the battery pack are analyzed and the main results are as follow: (1) Weibull and normal distribution are feasible to fit the capacity and resistance distribution of battery modules respectively; (2) SOC imbalance is the dominating factor in the capacity fading process of the battery pack; (3) By employing the incremental capacity (IC) and IC peak area analysis, a consistency evaluation method representing the aging mechanism variations of the battery modules is proposed and then an accurate battery screening strategy is put forward. This study not only provides data support for evaluating economic benefits of retired batteries but also presents a method to recognize the battery aging variations, which is helpful for rapid evaluation and screening of retired batteries for 2nd use.

  14. Challenges in IC design for hearing aids

    DEFF Research Database (Denmark)

    Jørgensen, Ivan Harald Holger

    2012-01-01

    Designing modern hearing aids is a formidable challenge. The size of hearing aids is constantly decreasing, making them virtually invisible today. Still, as in all other modern electronics, more and more features are added to these devices driven by the development in modern IC technology....... The demands for performance and features at very low supply voltage and power consumption constantly prove a challenge to the physical design of hearing aids and not at least the design of the ICs for these. As a result of this all large hearing aid manufacturers use fully customized ASICs in their products...... to produce a competitive advantage. This presentation will give a brief insight into the hearing aid market and industry, a brief view of the historic development of hearing aids and an introduction to how a modern hearing is constructed showing the amplifier as the key component in the modern hearing aid...

  15. Simulation of design dependent failure exposure levels for CMOS ICs

    International Nuclear Information System (INIS)

    Kaul, N.; Bhuva, B.L.; Rangavajjhala, V.; van der Molen, H.; Kerns, S.E.

    1990-01-01

    The total dose exposure of CMOS ICs introduces bias-dependent parameter shifts in individual devices. The bias dependency of individual parameter shifts of devices cause different designs to behave differently under identical testing conditions. This paper studies the effect of design and bias on the radiation tolerance of ICs and presents an automated design tool that produces different designs for a logic function, and presents important parameters of each design to circuit designer for trade off analysis

  16. A combined thermodynamic cycle based on methanol dissociation for IC (internal combustion) engine exhaust heat recovery

    International Nuclear Information System (INIS)

    Fu, Jianqin; Liu, Jingping; Xu, Zhengxin; Ren, Chengqin; Deng, Banglin

    2013-01-01

    In this paper, a novel approach for exhaust heat recovery was proposed to improve IC (internal combustion) engine fuel efficiency and also to achieve the goal for direct usage of methanol as IC engine fuel. An open organic Rankine cycle system using methanol as working medium is coupled to IC engine exhaust pipe for exhaust heat recovery. In the bottom cycle, the working medium first undergoes dissociation and expansion processes, and is then directed back to IC engine as fuel. As the external bottom cycle and the IC engine main cycle are combined together, this scheme forms a combined thermodynamic cycle. Then, this concept was applied to a turbocharged engine, and the corresponding simulation models were built for both of the external bottom cycle and the IC engine main cycle. On this basis, the energy saving potential of this combined cycle was estimated by parametric analyses. Compared to the methanol vapor engine, IC engine in-cylinder efficiency has an increase of 1.4–2.1 percentage points under full load conditions, while the external bottom cycle can increase the fuel efficiency by 3.9–5.2 percentage points at the working pressure of 30 bar. The maximum improvement to the IC engine global fuel efficiency reaches 6.8 percentage points. - Highlights: • A combined thermodynamic cycle using methanol as working medium for IC engine exhaust heat recovery is proposed. • The external bottom cycle of exhaust heat recovery and IC engine working cycle are combined together. • IC engine fuel efficiency could be improved from both in-cylinder working cycle and external bottom cycle. • The maximum improvement to the IC engine global fuel efficiency reaches 6.8 percentage points at full load

  17. IC3 Internet and Computing Core Certification Global Standard 4 study guide

    CERN Document Server

    Rusen, Ciprian Adrian

    2015-01-01

    Hands-on IC3 prep, with expert instruction and loads of tools IC3: Internet and Computing Core Certification Global Standard 4 Study Guide is the ideal all-in-one resource for those preparing to take the exam for the internationally-recognized IT computing fundamentals credential. Designed to help candidates pinpoint weak areas while there's still time to brush up, this book provides one hundred percent coverage of the exam objectives for all three modules of the IC3-GS4 exam. Readers will find clear, concise information, hands-on examples, and self-paced exercises that demonstrate how to per

  18. PTF 12gzk—A rapidly declining, high-velocity type Ic radio supernova

    Energy Technology Data Exchange (ETDEWEB)

    Horesh, Assaf; Kulkarni, Shrinivas R. [Cahill Center for Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Corsi, Alessandra [Department of Physics, The George Washington University, 725 21st Street, NW, Washington, DC 20052 (United States); Frail, Dale A. [National Radio Astronomy Observatory, P.O. Box 0, Socorro, NM 87801 (United States); Cenko, S. Bradley [Department of Astronomy, University of California, Berkeley, CA 94720-3411 (United States); Ben-Ami, Sagi; Gal-Yam, Avishay; Yaron, Ofer; Arcavi, Iair; Ofek, Eran O. [Department of Particle Physics and Astrophysics, The Weizmann Institute of Science, Rehovot 76100 (Israel); Kasliwal, Mansi M. [Carnegie Institution for Science, Department of Terrestrial Magnetism, 5241 Broad Branch Road, Washington, DC 20008 (United States)

    2013-11-20

    Only a few cases of Type Ic supernovae (SNe) with high-velocity ejecta (≥0.2 c) have been discovered and studied. Here, we present our analysis of radio and X-ray observations of the Type Ic SN PTF 12gzk. The radio emission declined less than 10 days after explosion, suggesting SN ejecta expanding at high velocity (∼0.3 c). The radio data also indicate that the density of the circumstellar material (CSM) around the supernova is lower by a factor of ∼10 than the CSM around normal Type Ic SNe. PTF 12gzk may therefore be an intermediate event between a 'normal' SN Ic and a gamma-ray-burst-SN-like event. Our observations of this rapidly declining radio SN at a distance of 58 Mpc demonstrates the potential to detect many additional radio SNe, given the new capabilities of the Very Large Array (improved sensitivity and dynamic scheduling), which are currently missed, leading to a biased view of radio SNe Ic. Early optical discovery followed by rapid radio observations would provide a full description of the ejecta velocity distribution and CSM densities around stripped massive star explosions as well as strong clues about the nature of their progenitor stars.

  19. PTF 12gzk—A rapidly declining, high-velocity type Ic radio supernova

    International Nuclear Information System (INIS)

    Horesh, Assaf; Kulkarni, Shrinivas R.; Corsi, Alessandra; Frail, Dale A.; Cenko, S. Bradley; Ben-Ami, Sagi; Gal-Yam, Avishay; Yaron, Ofer; Arcavi, Iair; Ofek, Eran O.; Kasliwal, Mansi M.

    2013-01-01

    Only a few cases of Type Ic supernovae (SNe) with high-velocity ejecta (≥0.2 c) have been discovered and studied. Here, we present our analysis of radio and X-ray observations of the Type Ic SN PTF 12gzk. The radio emission declined less than 10 days after explosion, suggesting SN ejecta expanding at high velocity (∼0.3 c). The radio data also indicate that the density of the circumstellar material (CSM) around the supernova is lower by a factor of ∼10 than the CSM around normal Type Ic SNe. PTF 12gzk may therefore be an intermediate event between a 'normal' SN Ic and a gamma-ray-burst-SN-like event. Our observations of this rapidly declining radio SN at a distance of 58 Mpc demonstrates the potential to detect many additional radio SNe, given the new capabilities of the Very Large Array (improved sensitivity and dynamic scheduling), which are currently missed, leading to a biased view of radio SNe Ic. Early optical discovery followed by rapid radio observations would provide a full description of the ejecta velocity distribution and CSM densities around stripped massive star explosions as well as strong clues about the nature of their progenitor stars.

  20. CMOS Analog IC Design: Fundamentals

    OpenAIRE

    Bruun, Erik

    2018-01-01

    This book is intended for use as the main textbook for an introductory course in CMOS analog integrated circuit design. It is aimed at electronics engineering students who have followed basic courses in mathematics, physics, circuit theory, electronics and signal processing. It takes the students directly from a basic level to a level where they can start working on simple analog IC design projects or continue their studies using more advanced textbooks in the field. A distinct feature of thi...

  1. EVIDENCE FOR AN INTERACTION IN THE NEAREST STARBURSTING DWARF IRREGULAR GALAXY IC 10

    International Nuclear Information System (INIS)

    Nidever, David L.; Slater, Colin T.; Bell, Eric F.; Ashley, Trisha; Simpson, Caroline E.; Ott, Jürgen; Johnson, Megan; Stanimirović, Snežana; Putman, Mary; Majewski, Steven R.; Jütte, Eva; Oosterloo, Tom A.; Burton, W. Butler

    2013-01-01

    Using deep 21 cm H I data from the Green Bank Telescope we have detected an ≳18.3 kpc long gaseous extension associated with the starbursting dwarf galaxy IC 10. The newly found feature stretches 1.°3 to the northwest and has a large radial velocity gradient reaching to ∼65 km s –1 lower than the IC 10 systemic velocity. A region of higher column density at the end of the extension that possesses a coherent velocity gradient (∼10 km s –1 across ∼26') transverse to the extension suggests rotation and may be a satellite galaxy of IC 10. The H I mass of IC 10 is 9.5 × 10 7 (d/805 kpc) 2 M ☉ and the mass of the new extension is 7.1 × 10 5 (d/805 kpc) 2 M ☉ . An IC 10-M31 orbit using known radial velocity and proper motion values for IC 10 show that the H I extension is inconsistent with the trailing portion of the orbit so that an M31-tidal or ram pressure origin seems unlikely. We argue that the most plausible explanation for the new feature is that it is the result of a recent interaction (and possible late merger) with another dwarf galaxy. This interaction could not only have triggered the origin of the recent starburst in IC 10, but could also explain the existence of previously found counter-rotating H I gas in the periphery of the IC 10 which was interpreted as originating from primordial gas infall

  2. Variabilidad del patrón respiratorio durante la carga elástica inspiratoria Variability of breathing pattern during inspiratory elastic load

    Directory of Open Access Journals (Sweden)

    Carlos E. D´Negri

    2009-06-01

    Full Text Available La ventilación pulmonar en humanos tiene una variabilidad respiración a respiración no lineal, compleja y caótica. El objetivo del trabajo fue: caracterizar la variabilidad del patrón respiratorio en perros (n: 8 anestesiados respirando bajo carga elástica umbral (CEU inspiratoria (7 a 50 cm H2O. Con el flujo, presión traqueal y esofágica, se analizaron: tiempo inspiratorio (Ti, ritmo [tiempo espiratorio (Te; tiempo total (Ttot, y Ti/Ttot] e impulso central (Vt/Ti, variables relacionadas [volumen corriente (Vt y ventilación pulmonar (Ve]. Se determinaron: variabilidad grosera (varianzas, oscilaciones de baja frecuencia (análisis espectral y memoria a corto plazo (análisis de autocorrelación. La CEU produjo disminución de la varianza de medias en Te, Ttot, Vt y Vt/Ti (p In humans, lung ventilation exhibits breath-to-breath variability and dynamics that are nonlinear, complex and chaotic. Our objective was to characterize the breathing pattern variational activity in anesthetized dogs (n: 8 breathing through threshold inspiratory elastic load (7 to 50 cm H2O. Starting from flow signal and tracheal and esophageal pressures, we analyzed inspiratory time (Ti, timing (expiratory time, Te; total time, Ttot; and Ti/Ttot and central drive (Vt/Ti and variables related to it (tidal volume, Vt and pulmonary ventilation, Ve. We measured gross variability (variances, low frequency oscillations (spectral analysis, and short term memory (autocorrelation analysis. Loading decreased variance of the mean values of Te, Ttot, Vt and Vt/Ti (p < 0.05; the mean of variances for Ti/Ttot increased (p < 0.005 while it decreased for Vt and Vt/Ti (p < 0.05. In general, percent of data recordings with low frequency oscillations (OB% decreased (p < 0.02. During heavy load, timing parameters percent of data recordings with autocorrelations (AU% did not change, but Vt and its related parameters decreased their AU% (p < 0.005. There was a positive correlation (r: 0

  3. A Solder Based Self Assembly Project in an Introductory IC Fabrication Course

    Science.gov (United States)

    Rao, Madhav; Lusth, John C.; Burkett, Susan L.

    2015-01-01

    Integrated circuit (IC) fabrication principles is an elective course in a senior undergraduate and early graduate student's curriculum. Over the years, the semiconductor industry relies heavily on students with developed expertise in the area of fabrication techniques, learned in an IC fabrication theory and laboratory course. The theory course…

  4. Electronic States of IC60BA and PC71BM

    International Nuclear Information System (INIS)

    Sheng Chun-Qi; Wang Peng; Shen Ying; Li Wen-Jie; Li Hong-Nian; Zhang Wen-Hua; Zhu Jun-Fa; Lai Guo-Qiao

    2013-01-01

    We investigate the electronic states of IC 60 BA and PC 71 BM using first-principles calculations and photoelectron spectroscopy (PES) measurements. The energy level structures for all possible isomers are reported and compared with those of C 60 , C 70 and PC 61 BM. The attachment of the side chains can raise the LUMO energies and decrease the HOMO-LUMO gaps, and thus helps to increase the power-conversion efficiency of bulk heterojunction solar cells. In the PES studies, we prepared IC 60 BA and PC 71 BM films on Si:H(111) substrates to construct adsorbate/substrate interfaces describable with the integer charge-transfer (ICT) model. Successful measurements then revealed that one of the most important material properties for an electron acceptor, the energy of the negative integer charge-transfer state (E ICT− ), is 4.31 eV below the vacuum level for PC 71 BM. The E ICT− of IC 60 BA is smaller than 4.14 eV

  5. Consciência icônica: o sentimento material do significado

    Directory of Open Access Journals (Sweden)

    Jeffrey C. Alexander

    Full Text Available Resumo Neste ensaio seminal, Jeffrey Alexander apresenta algumas das bases de sua virada icônica. O giro analítico proposto se fundamenta em uma compreensão da materialidade como portadora de conteúdo estético e moral, o que é sintetizado na noção de consciência icônica: o processo em que um observador vincula a superfície estética de uma materialidade a uma determinada estrutura moral de valores sociais.

  6. APPLICATTON OF SCTENTIF'IC PRINCIPLES IN MERINO SHEEP ...

    African Journals Online (AJOL)

    THE PRACTICAI- APPLICATTON OF SCTENTIF'IC PRINCIPLES IN MERINO SHEEP BREEDING. C.A. van der ..... There is, however, no practical evidence in this ... 1910" Comparison of three Australian merino strains for wool and body traits.

  7. EVN observations of the OH megamaser galaxies Mrk 231 and IC 694

    NARCIS (Netherlands)

    Klockner, HR; Baan, WA; Migenes,; Reid, MJ

    2002-01-01

    We present EVN observations of hydroxyl (OH) main-line emission in two megamaser sources Mrk 231 and IC 694. The observations indicate that the broad maser emission lines originate within the nuclear regions. A single 1667 MHz main-line feature is seen at the nucleus of IC 694. In Mrk 231 both

  8. IC 3475: A stripped dwarf galaxy in the Virgo cluster

    International Nuclear Information System (INIS)

    Vigroux, L.; Thuan, T.X.; Vader, J.P.; Lachieze-Rey, M.

    1986-01-01

    We have obtained B and R CCD and H I observations of the Virgo dwarf galaxy IC 3475. The galaxy is remarkable for its very large diameter (approx.10 kpc for a Virgo distance modulus of 31) and is comparable in size to the large dwarfs discussed by Sandage and Binggeli. Its light profile is best fitted by an exponential law, characteristic of a dwarf Magellanic irregular galaxy. It possesses a central bar with many knots and inclusions concentrated toward the center of the galaxy. These knots and inclusions have the same color (B-Rapprox.1.5) as the rest of the galaxy and are best explained as intermediate-age (1--7 x 10 9 yr) star clusters such as those found in the Magellanic Clouds. Despite possessing the photometric structure of a dwarf Magellanic irregular galaxy, IC 3475 contains less than 5.3 x 10 6 M/sub sun/ of neutral hydrogen. Its hydrogen mass to blue light ratio is less than 0.01, approx.60 times less than the mean value observed for dwarf Magellanic irregulars. It is most likely that IC 3475, which is located near the core of the Virgo cluster, is a stripped dwarf galaxy. The very large size of the galaxy (its diameter is approx.1.8 times larger than that of ''normal'' dwarfs) appears to rule out evolution of IC 3475 from a normal dwarf irregular or to a normal dwarf elliptical

  9. The defective nature of ice Ic and its implications for atmospheric science

    Science.gov (United States)

    Kuhs, W. F.; Hansen, T. C.

    2009-04-01

    The possible atmospheric implication of ice Ic (cubic ice) has already been suggested some time ago in the context of snow crystal formation [1]. New findings from air-borne measurements in cirrus clouds and contrails have put ice Ic into the focus of interest to understand the so-called "supersaturation puzzle" [2,3,4,5]. Our recent microstructural work on ice Ic [6,7] appears to be highly relevant in this context. We have found that ice Ic is characterized by a complex stacking fault pattern, which changes as a function of temperature as well as time. Indeed, from our own [8] and other group's work [9] one knows that (in contrast to earlier believe) ice Ic can form up to temperatures at least as high as 240K - thus in the relevant range for cirrus clouds. We have good preliminary evidence that the "cubicity" (which can be related to stacking fault probabilities) as well as the particle size of ice Ic are the relevant parameters for this correlation. The "cubicity" of stacking faulty ice Ic (established by diffraction) correlates nicely with the increased supersaturation at decreasing temperatures observed in cirrus clouds and contrails, a fact, which may be considered as further evidence for the presence of ice Ic. Moreover, the stacking faults lead to kinks in the outer shapes of the minute ice Ic crystals as seen by cryo scanning electron microscopy (cryo-SEM); these defective sites are likely to play some role in heterogeneous reactions in the atmosphere. The cryo-SEM work suggests that stacking-faulty ice Ic has many more active centres for such reactions than the usually considered thermodynamically stable form, ice Ih. [1] T Kobayashi & T Kuroda (1987) Snow Crystals. In: Morphology of Crystals (ed. I Sunagawa), Terra Scientific Publishing, Tokyo, pp.649-743. [2] DM Murphy (2003) Dehydration in cold clouds is enhanced by a transition from from cubic to hexagonal ice. Geophys.Res.Lett.,30, 2230, doi:10.1029/2003GL018566. [3] RS Gao & 19 other authors (2004

  10. Evaluation of accelerated test parameters for CMOS IC total dose hardness prediction

    International Nuclear Information System (INIS)

    Sogoyan, A.V.; Nikiforov, A.Y.; Chumakov, A.I.

    1999-01-01

    The approach to accelerated test parameters evaluation is presented in order to predict CMOS IC total dose behavior in variable dose-rate environment. The technique is based on the analytical model of MOSFET parameters total dose degradation. The simple way to estimate model parameter is proposed using IC's input-output MOSFET radiation test results. (authors)

  11. EMERGING I&C TECHNOLOGIES UNDER THE SHIFTING REGULATORY ENVIRONMENT IN SOUTH KOREA

    Directory of Open Access Journals (Sweden)

    Gyunyoung eHeo

    2015-04-01

    Full Text Available The role of Probabilistic Safety Assessment (PSA has been supplementary and Risk-Informed Applications (RIAs based on the insight from PSA has also been utilized limitedly in the licensing process for Nuclear Power Plants (NPPs in South Korea. However, as the technical significance of PSA is getting increased, PSA has become a mandatory part of Safety Analysis Reports and Periodic Safety Review. It is worthwhile to highlight the role of emerging Instrumentation and Control (I&C technologies including human-machine interface (HMI in developing more credible and realistic PSA models. Particularly, it is expected that the information technology (i.e. software embedded in digital I&C can adjust over- and under conservatism in analyzing risk. In this study, authors proposed the cases which would be able to significantly reduce risk if advanced I&C supported by information technologies is applied. In regard, the several enabling techniques and their effects are proposed. In order to improve the commercial competitiveness of NPPs, the need of collaboration and synergetic outcome of I&C, HMI and PSA should be emphasized.

  12. Emerging I&C Technologies Under the Shifting Regulatory Environment in South Korea

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Gyunyoung [Department of Nuclear Engineering, Kyung Hee University, Youngin-si (Korea, Republic of); Seong, Poong Hyun; Kang, Hyun Gook, E-mail: hyungook@kaist.ac.kr [Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2015-04-29

    The role of probabilistic safety assessment (PSA) has been supplementary and risk-informed applications based on the insight from PSA have also been utilized limitedly in the licensing process for nuclear power plants (NPPs) in South Korea. However, as the technical significance of PSA is getting increased, PSA has become a mandatory part of Safety Analysis Reports and Periodic Safety Review. It is worthwhile to highlight the role of emerging instrumentation and control (I&C) technologies including human–machine interface (HMI) in developing more credible and realistic PSA models. Particularly, it is expected that the information technology (i.e., software) embedded in digital I&C can adjust over- and under conservatism in analyzing risk. In this study, authors proposed the cases which would be able to significantly reduce risk if advanced I&C supported by information technologies is applied. In regard, the several enabling techniques and their effects are proposed. In order to improve the commercial competitiveness of NPPs, the need of collaboration and synergetic outcome of I&C, HMI, and PSA should be emphasized.

  13. STAR FORMATION ASSOCIATED WITH THE SUPERNOVA REMNANT IC443

    International Nuclear Information System (INIS)

    Xu Jinlong; Wang Junjie; Miller, Martin

    2011-01-01

    We have performed submillimeter and millimeter observations in CO lines toward supernova remnant (SNR) IC443. The CO molecular shell coincides well with the partial shell of the SNR detected in radio continuum observations. Broad emission lines and three 1720 MHz OH masers were detected in the CO molecular shell. The present observations have provided further evidence in support of the interaction between the SNR and the adjoining molecular clouds (MCs). The total mass of the MCs is 9.26 x 10 3 M sun . The integrated CO line intensity ratio (R I CO(3-2) /I CO(2-1) ) for the whole MC is between 0.79 and 3.40. The average value is 1.58, which is much higher than previous measurements of individual Galactic MCs. Higher line ratios imply that shocks have driven into the MCs. We conclude that high R I CO(3-2) /I CO(2-1) is identified as a good signature of the SNR-MC interacting system. Based on the IRAS Point Source Catalog and the Two Micron All Sky Survey near-infrared database, 12 protostellar object and 1666 young stellar object (YSO) candidates (including 154 classical T Tauri stars and 419 Herbig Ae/Be stars) are selected. In the interacting regions, the significant enhancement of the number of protostellar objects and YSOs indicates the presence of some recently formed stars. After comparing the characteristic timescales of star formation with the age of IC443, we conclude that the protostellar objects and YSO candidates are not triggered by IC443. For the age of the stellar winds shell, we have performed our calculation on the basis of a stellar wind shell expansion model. The results and analysis suggest that the formation of these stars may be triggered by the stellar winds of the IC443 progenitor.

  14. Quantitative assessment of global and regional air trappings using non-rigid registration and regional specific volume change of inspiratory/expiratory CT scans: Studies on healthy volunteers and asthmatics

    International Nuclear Information System (INIS)

    Lee, Eun Sol; Seo, Joon Beom; Lee, Hyun Joo; Chae, Eun Jin; Lee, Sang Min; Oh, Sang Young; Kim, Nam Kug

    2015-01-01

    The purpose of this study was to compare air trapping in healthy volunteers with asthmatics using pulmonary function test and quantitative data, such as specific volume change from paired inspiratory CT and registered expiratory CT. Sixteen healthy volunteers and 9 asthmatics underwent paired inspiratory/expiratory CT. DeltaSV, which represents the ratio of air fraction released after exhalation, was measured with paired inspiratory and anatomically registered expiratory CT scans. Air trapping indexes, DeltaSV0.4 and DeltaSV0.5, were defined as volume fraction of lung below 0.4 and 0.5 DeltaSV, respectively. To assess the gravity effect of air-trapping, DeltaSV values of anterior and posterior lung at three different levels were measured and DeltaSV ratio of anterior lung to posterior lung was calculated. Color-coded DeltaSV map of the whole lung was generated and visually assessed. Mean DeltaSV, DeltaSV0.4, and DeltaSV0.5 were compared between healthy volunteers and asthmatics. In asthmatics, correlation between air trapping indexes and clinical parameters were assessed. Mean DeltaSV, DeltaSV0.4, and DeltaSV0.5 in asthmatics were significantly higher than those in healthy volunteer group (all p < 0.05). DeltaSV values in posterior lung in asthmatics were significantly higher than those in healthy volunteer group (p = 0.049). In asthmatics, air trapping indexes, such as DeltaSV0.5 and DeltaSV0.4, showed negative strong correlation with FEF25-75, FEV1, and FEV1/FVC. DeltaSV map of asthmatics showed abnormal geographic pattern in 5 patients (55.6%) and disappearance of anterior-posterior gradient in 3 patients (33.3%). Quantitative assessment of DeltaSV (the ratio of air fraction released after exhalation) shows the difference in extent of air trapping between health volunteers and asthmatics.

  15. Quantitative assessment of global and regional air trappings using non-rigid registration and regional specific volume change of inspiratory/expiratory CT scans: Studies on healthy volunteers and asthmatics

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Sol; Seo, Joon Beom; Lee, Hyun Joo; Chae, Eun Jin; Lee, Sang Min; Oh, Sang Young; Kim, Nam Kug [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2015-06-15

    The purpose of this study was to compare air trapping in healthy volunteers with asthmatics using pulmonary function test and quantitative data, such as specific volume change from paired inspiratory CT and registered expiratory CT. Sixteen healthy volunteers and 9 asthmatics underwent paired inspiratory/expiratory CT. DeltaSV, which represents the ratio of air fraction released after exhalation, was measured with paired inspiratory and anatomically registered expiratory CT scans. Air trapping indexes, DeltaSV0.4 and DeltaSV0.5, were defined as volume fraction of lung below 0.4 and 0.5 DeltaSV, respectively. To assess the gravity effect of air-trapping, DeltaSV values of anterior and posterior lung at three different levels were measured and DeltaSV ratio of anterior lung to posterior lung was calculated. Color-coded DeltaSV map of the whole lung was generated and visually assessed. Mean DeltaSV, DeltaSV0.4, and DeltaSV0.5 were compared between healthy volunteers and asthmatics. In asthmatics, correlation between air trapping indexes and clinical parameters were assessed. Mean DeltaSV, DeltaSV0.4, and DeltaSV0.5 in asthmatics were significantly higher than those in healthy volunteer group (all p < 0.05). DeltaSV values in posterior lung in asthmatics were significantly higher than those in healthy volunteer group (p = 0.049). In asthmatics, air trapping indexes, such as DeltaSV0.5 and DeltaSV0.4, showed negative strong correlation with FEF25-75, FEV1, and FEV1/FVC. DeltaSV map of asthmatics showed abnormal geographic pattern in 5 patients (55.6%) and disappearance of anterior-posterior gradient in 3 patients (33.3%). Quantitative assessment of DeltaSV (the ratio of air fraction released after exhalation) shows the difference in extent of air trapping between health volunteers and asthmatics.

  16. Association between sarcopenia and higher-level functional capacity in daily living in community-dwelling elderly subjects in Japan.

    Science.gov (United States)

    Tanimoto, Yoshimi; Watanabe, Misuzu; Sun, Wei; Sugiura, Yumiko; Tsuda, Yuko; Kimura, Motoshi; Hayashida, Itsushi; Kusabiraki, Toshiyuki; Kono, Koichi

    2012-01-01

    This study aimed to determine the association between sarcopenia, defined by muscle mass, muscle strength, and physical performance, and higher-level functional capacity in community-dwelling Japanese elderly people. Subjects were 1158 elderly, community-dwelling Japanese people aged 65 or older. We used bioelectrical impedance analysis to measure muscle mass, grip strength to measure muscle strength, and usual walking speed to measure physical performance. Sarcopenia was characterized by low muscle mass, plus low muscle strength or low physical performance. Subjects without low muscle mass, low muscle strength, and low physical performance were classified as "normal." Examination of higher-level functional capacity was performed using the Tokyo Metropolitan Institute of Gerontology Index of Competence (TMIG-IC). The TMIG-IC is a 13-item questionnaire completed by the subject; it contains five questions on self-maintenance and four questions each on intellectual activity and social role. Sarcopenia was identified in 11.3% and 10.7% of men and women, respectively. The percentage of disability for instrumental activities of daily living (IADL) was 39.0% in men with sarcopenia and 30.6% in women with sarcopenia. After adjustment for age, in men, sarcopenia was significantly associated with IADL disability compared with intermediate and normal subjects. In women, sarcopenia was significantly associated with every subscale of the TMIG-IC disability compared with intermediate and normal subjects. This study revealed that sarcopenia, defined by muscle mass, muscle strength, and physical performance, had a significant association with disability in higher-level functional capacity in elderly Japanese subjects. Interventions to prevent sarcopenia may prevent higher-level functional disability among elderly people. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. Virtual design and qualification of IC backend structures

    NARCIS (Netherlands)

    Silfhout, van R.B.R.; Sluis, van der O.; Driel, van W.D.; Janssen, J.H.J.; Zhang, G.Q.

    2006-01-01

    For Integrated Circuit (IC) wafer backend development, process developers have to design robust backend structures that guarantee both functionality and reliability during waferfab processes, packaging, qualification tests and lifetime. Figure 1 shows a simplified diagram for the design (and

  18. Effect of Aerobic Exercise Training on Ventilatory Efficiency and Respiratory Drive in Obese Subjects.

    Science.gov (United States)

    Chlif, Mehdi; Chaouachi, Anis; Ahmaidi, Said

    2017-07-01

    Obese patients show a decline in exercise capacity and diverse degrees of dyspnea in association with mechanical abnormalities, increased ventilatory requirements secondary to the increased metabolic load, and a greater work of breathing. Consequently, obese patients may be particularly predisposed to the development of respiratory muscle fatigue during exercise. The aim of this study was to assess inspiratory muscle performance during incremental exercise in 19 obese male subjects (body mass index 41 ± 6 kg/m 2 ) after aerobic exercise training using the noninvasive, inspiratory muscle tension-time index (T T0.1 ). Measurements performed included anthropometric parameters, lung function assessed by spirometry, rate of perceived breathlessness with the modified Borg dyspnea scale (0-10), breathing pattern, maximal exercise capacity, and inspiratory muscle performance with a breath-by-breath automated exercise metabolic system during an incremental exercise test. T T0.1 was calculated using the equation, T T0.1 = P 0.1 /P Imax × T I /T tot (where P 0.1 represents mouth occlusion pressure, P Imax is maximal inspiratory pressure, and T I /T tot is the duty cycle). At rest, there was no statistically significant difference for spirometric parameters and cardiorespiratory parameters between pre- and post-training. At maximal exercise, the minute ventilation, the rate of exchange ratio, the rate of perceived breathlessness, and the respiratory muscle performance parameters were not significantly different pre- and post-training; in contrast, tidal volume ( P = .037, effect size = 1.51), breathing frequency ( P = .049, effect size = 0.97), power output ( P = .048, effect size = 0.79), peak oxygen uptake ( P = .02, effect size = 0.92) were significantly higher after training. At comparable work load, training induces lower minute ventilation, mouth occlusion pressure, ratio of occlusion pressure to maximal inspiratory pressure, T T0.1 , and rate of perceived

  19. IC modelling in the IRSN EPR level 1 PSA

    International Nuclear Information System (INIS)

    Delache, J.

    2012-01-01

    Today in France, an EPR (European Pressurized Water Reactor) Unit is under construction at the Flamanville site. The creation authorization was granted in April 2007 and the plant commissioning is planned for 2012. The plant operator (EDF) provided for the construction license several PSA (Probabilistic Safety Assessment) studies. IRSN, as TSO (Technical Safety Organisation), wishes to dispose of the appropriate knowledge and tools for the independent verification of the operator studies and so developed its own model of PSA level 1. The goal is not to rebuild the plant operator PSA (with a full scope...) but to dispose of a simplified model able to clearly point out specific important issues. In the IRSN model a particular effort has recently been done on the Digital IC modelling. The IC (Instrumentation and Control) is modelled in the IRSN EPR PSA by using Fault Trees. Instead, EDF EPR PSA applies the COMPACT model to simplify the command and instrumentation logics. The IRSN model is more detailed in order to be more accurate in the global analysis of the Digital IC. For instance the communication ways between automates are considered as well as the failure of support systems. The model is still under development mainly in order to define the CCF (Common Cause Failure) which may be considered. (authors)

  20. Effect of heat and moisture exchanger (HME positioning on inspiratory gas humidification

    Directory of Open Access Journals (Sweden)

    Nishimura Masaji

    2006-08-01

    Full Text Available Abstract Background In mechanically ventilated patients, we investigated how positioning the heat and moisture exchanger (HME at different places on the ventilator circuit affected inspiratory gas humidification. Methods Absolute humidity (AH and temperature (TEMP at the proximal end of endotracheal tube (ETT were measured in ten mechanically ventilated patients. The HME was connected either directly proximal to the ETT (Site 1 or at before the circuit Y-piece (Site 2: distance from proximal end of ETT and Site 2 was about 19 cm (Figure. 1. Two devices, Hygrobac S (Mallinckrodt Dar, Mirandola, Italy and Thermovent HEPA (Smiths Medical International Ltd., Kent, UK were tested. AH and TEMP were measured with a hygrometer (Moiscope, MERA Co., Ltd., Tokyo, Japan. Results Hygrobac S provided significantly higher AH and TEMP at both sites than Thermovent HEPA. Both Hygrobac S and with Thermovent HEPA provided significantly higher AH and TEMP when placed proximally to the ETT. Conclusion Although placement proximal to the ETT improved both AH and TEMP in both HMEs tested, one HME performed better in the distal position than the other HME in the proximal position. We conclude the both the type and placement of HME can make a significant difference in maintaining AH and TEMP during adult ventilation.

  1. Effect of heat and moisture exchanger (HME) positioning on inspiratory gas humidification

    Science.gov (United States)

    Inui, Daisuke; Oto, Jun; Nishimura, Masaji

    2006-01-01

    Background In mechanically ventilated patients, we investigated how positioning the heat and moisture exchanger (HME) at different places on the ventilator circuit affected inspiratory gas humidification. Methods Absolute humidity (AH) and temperature (TEMP) at the proximal end of endotracheal tube (ETT) were measured in ten mechanically ventilated patients. The HME was connected either directly proximal to the ETT (Site 1) or at before the circuit Y-piece (Site 2: distance from proximal end of ETT and Site 2 was about 19 cm) (Figure. 1). Two devices, Hygrobac S (Mallinckrodt Dar, Mirandola, Italy) and Thermovent HEPA (Smiths Medical International Ltd., Kent, UK) were tested. AH and TEMP were measured with a hygrometer (Moiscope, MERA Co., Ltd., Tokyo, Japan). Results Hygrobac S provided significantly higher AH and TEMP at both sites than Thermovent HEPA. Both Hygrobac S and with Thermovent HEPA provided significantly higher AH and TEMP when placed proximally to the ETT. Conclusion Although placement proximal to the ETT improved both AH and TEMP in both HMEs tested, one HME performed better in the distal position than the other HME in the proximal position. We conclude the both the type and placement of HME can make a significant difference in maintaining AH and TEMP during adult ventilation. PMID:16895607

  2. A GRB and Broad-lined Type Ic Supernova from a Single Central Engine

    Science.gov (United States)

    Barnes, Jennifer; Duffell, Paul C.; Liu, Yuqian; Modjaz, Maryam; Bianco, Federica B.; Kasen, Daniel; MacFadyen, Andrew I.

    2018-06-01

    Unusually high velocities (≳0.1c) and correspondingly high kinetic energies have been observed in a subset of Type Ic supernovae (so-called “broad-lined Ic” supernovae; SNe Ic-BL), prompting a search for a central engine model capable of generating such energetic explosions. A clue to the explosion mechanism may lie in the fact that all supernovae that accompany long-duration gamma-ray bursts (GRBs) belong to the SN Ic-BL class. Using a combination of two-dimensional relativistic hydrodynamics and radiation transport calculations, we demonstrate that the central engine responsible for long GRBs can also trigger an SN Ic-BL. We find that a reasonable GRB engine injected into a stripped Wolf–Rayet progenitor produces a relativistic jet with energy ∼1051 erg, as well as an SN whose synthetic light curves and spectra are fully consistent with observed SNe Ic-BL during the photospheric phase. As a result of the jet’s asymmetric energy injection, the SN spectra and light curves depend on viewing angle. The impact of viewing angle on the spectrum is particularly pronounced at early times, while the viewing-angle dependence for the light curves (∼10% variation in bolometric luminosity) persists throughout the photospheric phase.

  3. The Effects of Industry Type, Company Size and Performance on Chinese Companies’ IC Disclosure: A Research Note

    Directory of Open Access Journals (Sweden)

    Yi An

    2011-09-01

    Full Text Available This paper examines the effects of industry type, firm size and corporate performance on intellectual capital (IC disclosure among Chinese (mainland companies. It was found that industry type did not have a significant influence on IC reporting practices of Chinese firms; the larger firms generally reported more IC information than the relatively smaller firms; and there was a positive relationship between corporate performance and IC disclosure. This paper contributes to fairly limited literature regarding the associations between the level of IC disclosure and a variety of relevant impact factors, in particular in the Chinese mainland context. In addition, the findings of this research provide some references for policy-makers while developing an IC reporting framework applicable to the Chinese environment.

  4. Segmentation of expiratory and inspiratory sounds in baby cry audio recordings using hidden Markov models.

    Science.gov (United States)

    Aucouturier, Jean-Julien; Nonaka, Yulri; Katahira, Kentaro; Okanoya, Kazuo

    2011-11-01

    The paper describes an application of machine learning techniques to identify expiratory and inspiration phases from the audio recording of human baby cries. Crying episodes were recorded from 14 infants, spanning four vocalization contexts in their first 12 months of age; recordings from three individuals were annotated manually to identify expiratory and inspiratory sounds and used as training examples to segment automatically the recordings of the other 11 individuals. The proposed algorithm uses a hidden Markov model architecture, in which state likelihoods are estimated either with Gaussian mixture models or by converting the classification decisions of a support vector machine. The algorithm yields up to 95% classification precision (86% average), and its ability generalizes over different babies, different ages, and vocalization contexts. The technique offers an opportunity to quantify expiration duration, count the crying rate, and other time-related characteristics of baby crying for screening, diagnosis, and research purposes over large populations of infants.

  5. CMOS analog integrated circuit design technology; CMOS anarogu IC sekkei gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, H.; Fujisawa, A. [Fuji Electric Co. Ltd., Tokyo (Japan)

    2000-08-10

    In the field of the LSI (large scale integrated circuit) in rapid progress toward high integration and advanced functions, CAD (computer-aided design) technology has become indispensable to LSI development within a short period. Fuji Electric has developed design technologies and automatic design system to develop high-quality analog ICs (integrated circuits), including power supply ICs. within a short period. This paper describes CMOS (complementary metal-oxide semiconductor) analog macro cell, circuit simulation, automatic routing, and backannotation technologies. (author)

  6. Psychosocial co-morbidities in Interstitial Cystitis/Bladder Pain syndrome (IC/BPS): A systematic review.

    Science.gov (United States)

    McKernan, Lindsey C; Walsh, Colin G; Reynolds, William S; Crofford, Leslie J; Dmochowski, Roger R; Williams, David A

    2018-03-01

    Psychosocial factors amplify symptoms of Interstitial Cystitis (IC/BPS). While psychosocial self-management is efficacious in other pain conditions, its impact on an IC/BPS population has rarely been studied. The objective of this review is to learn the prevalence and impact of psychosocial factors on IC/BPS, assess baseline psychosocial characteristics, and offer recommendations for assessment and treatment. Following PRISMA guidelines, primary information sources were PubMed including MEDLINE, Embase, CINAHL, and GoogleScholar. Inclusion criteria included: (i) a clearly defined cohort with IC/BPS or with Chronic Pelvic Pain Syndrome provided the IC/BPS cohort was delineated with quantitative results from the main cohort; (ii) all genders and regions; (iii) studies written in English from 1995 to April 14, 2017; (iv) quantitative report of psychosocial factors as outcome measures or at minimum as baseline characteristics. Thirty-four of an initial 642 articles were reviewed. Quantitative analyses demonstrate the magnitude of psychosocial difficulties in IC/BPS, which are worse than average on all measures, and fall into areas of clinical concern for 7 out of 10 measures. Meta-analyses shows mean Mental Component Score of the Short-Form 12 Health Survey (MCS) of 40.80 (SD 6.25, N = 2912), where <36 is consistent with severe psychological impairment. Averaged across studies, the population scored in the range seen in clinical depression (CES-D 19.89, SD 13.12, N = 564) and generalized anxiety disorder (HADS-A 8.15, SD 4.85, N = 465). The psychological impact of IC/BPS is pervasive and severe. Existing evidence of treatment is lacking and suggests self-management intervention may be helpful. © 2017 Wiley Periodicals, Inc.

  7. Investment, managerial capacity, and bias in public health preparedness.

    Science.gov (United States)

    Langabeer, James R; DelliFraine, Jami L; Tyson, Sandra; Emert, Jamie M; Herbold, John

    2009-01-01

    Nearly $7 billion has been invested through national cooperative funding since 2002 to strengthen state and local response capacity. Yet, very little outcome evidence exists to analyze funding effectiveness. The objective of this research is to analyze the relationship between investment (funding) and capacity (readiness) for public health preparedness (PHP). The aim of the authors is to use a management framework to evaluate capacity, and to explore the "immediacy bias" impact on investment stability. This study employs a longitudinal study design, incorporating survey research of the entire population of 68 health departments in the state of Texas. The authors assessed the investment-capacity relationship through several statistical methods. The authors created a structural measure of managerial capacity through principal components analysis, factorizing 10 independent variables and augment this with a perceived readiness level reported from PHP managers. The authors then employ analysis of variance, correlation analyses, and other descriptive statistics. There has been a 539 percent coefficient of variation in funding at the local level between the years 2004 and 2008, and a 63 percent reduction in total resources since the peak of funding, using paired sample data. Results suggest that investment is positively associated with readiness and managerial capacity in local health departments. The authors also find that investment was related to greater community collaboration, higher adoption of Incident Command System (ICS) structure, and more frequent operational drills and exercises. Greater investment is associated with higher levels of capacity and readiness. The authors conclude from this that investment should be stabilized and continued, and not be influenced by historical cognitive biases.

  8. Evaluation of ultimate load bearing capacity of the primary containment of a typical first generation 220 MWe Indian PHWRs

    International Nuclear Information System (INIS)

    Singh, A.K.; Ray, I.; Roy, R.; Garg, R.P.; Verma, U.S.P.

    2005-01-01

    This paper presents the analysis of the Inner Containment Structure (ICS) of a typical first generation 220 MWe Indian PHWR for the purpose of evaluating its ultimate load bearing capacity (ULBC) beyond postulated design basis accident (DBA) scenario. The first generation ICS of Indian PHWRs are made of cylindrical wall capped with prestressed/reinforced cellular containment slab, which is connected monolithically to outer containment (OC) Wall to provide clamping effect during postulated DBA scenario. This paper discusses the simulation of construction sequence in analytical model, which is a very important aspect from point of view of capturing the residual stresses generated in the structure. The methodology adopted for the non-linear analysis of the prestressed concrete ICS including the various issues, viz. behaviour of concrete under compression and tension, tension stiffening, cracked shear modulus etc. have also been discussed in this paper. The effect of accident temperature on ULBC has been studied and discussed in this paper. This paper also discusses the study of mesh sensitivity of the finite element (FE) discretisation on ULBC of ICS in the non-linear range. Based on the detailed analysis, the factor of safety of the ICS beyond postulated DBA scenario has been evaluated. (authors)

  9. Computing fundamentals IC3 edition

    CERN Document Server

    Wempen, Faithe

    2014-01-01

    Kick start your journey into computing and prepare for your IC3 certification With this essential course book you'll be sending e-mails, surfing the web and understanding the basics of computing in no time. Written by Faithe Wempen, a Microsoft Office Master Instructor and author of more than 120 books, this complete guide to the basics has been tailored to provide comprehensive instruction on the full range of entry-level computing skills. It is a must for students looking to move into almost any profession, as entry-level computing courses have become a compulsory requirement in the modern w

  10. Advances in analog and RF IC design for wireless communication systems

    CERN Document Server

    Manganaro, Gabriele

    2013-01-01

    Advances in Analog and RF IC Design for Wireless Communication Systems gives technical introductions to the latest and most significant topics in the area of circuit design of analog/RF ICs for wireless communication systems, emphasizing wireless infrastructure rather than handsets. The book ranges from very high performance circuits for complex wireless infrastructure systems to selected highly integrated systems for handsets and mobile devices. Coverage includes power amplifiers, low-noise amplifiers, modulators, analog-to-digital converters (ADCs) and digital-to-analog converters

  11. A novel prototyping method for die-level monolithic integration of MEMS above-IC

    International Nuclear Information System (INIS)

    Cicek, Paul-Vahe; Zhang, Qing; Saha, Tanmoy; Mahdavi, Sareh; Allidina, Karim; Gamal, Mourad El; Nabki, Frederic

    2013-01-01

    This work presents a convenient and versatile prototyping method for integrating surface-micromachined microelectromechanical systems (MEMS) directly above IC electronics, at the die level. Such localized implementation helps reduce development costs associated with the acquisition of full-sized semiconductor wafers. To demonstrate the validity of this method, variants of an IC-compatible surface-micromachining MEMS process are used to build different MEMS devices above a commercial transimpedance amplifier chip. Subsequent functional assessments for both the electronics and the MEMS indicate that the integration is successful, validating the prototyping methodology presented in this work, as well as the suitability of the selected MEMS technology for above-IC integration. (paper)

  12. Efeitos de um programa de reabilitação da musculatura inspiratória no pós-operatório de cirurgia cardíaca Efectos de un programa de rehabilitación de la musculatura inspiratoria en el postoperatorio de cirugía cardiaca Effects of an inspiratory muscle rehabilitation program in the postoperative period of cardiac surgery

    Directory of Open Access Journals (Sweden)

    Paulo Eduardo Gomes Ferreira

    2009-04-01

    waiting for myocardial revascularization and/or cardiac valve surgery, were randomly assigned to two groups. Fifteen patients were included in a domiciliary program of at least 2 weeks of preoperative training of the inspiratory muscles, using a device with a load corresponding to 40% of the maximum inspiratory pressure. The other 15 patients received general advice and did not train the inspiratory muscle. Spirometry, before and after the training program, as well as the evolution of the arterial blood gases and of the maximum inspiratory and expiratory pressure, before and after the operation were evaluated in both group. The clinical outcomes of the two groups were also compared. RESULTS: We observed that inspiratory muscle training increased the forced vital capacity, the maximum voluntary ventilation and the ratio between the forced expired volume during the first second and the forced vital capacity. The evolution of the arterial blood gases and of the maximum inspiratory and expiratory pressures before and after the operation was similar in both groups, with the outcomes also being similar. CONCLUSION: We concluded that our domiciliary program of inspiratory muscle training was safe and improved the forced vital capacity and the maximum voluntary ventilation, although the clinical benefits of this program were not clearly demonstrable in the present study.

  13. The Mozart study: a relation between dynamic hyperinflation and physical activity in patients with chronic obstructive pulmonary disease?

    Science.gov (United States)

    van Leuteren, R W; Dijkhuis, S; de Jongh, F H C; van der Valk, P D L P M; Tabak, M; Brusse-Keizer, M G J

    2018-05-01

    Many patients with chronic obstructive pulmonary disease (COPD) experience dyspnoea during exercise, resulting in a reduction of physical activity (PA). Dynamic hyperinflation (DH) is seen as a major cause of dyspnoea in COPD. The objective of the current study was to investigate the relationship between DH, in terms of the amount of DH and the development and recovery rate of DH in patients with COPD, and PA. Thirty-five patients with stable COPD were included from an outpatient clinic (14 GOLD II and 21 GOLD III, median age 65). PA was assessed using an accelerometer. Subjects underwent metronome-paced tachypnoea (MPT) to induce DH. To quantify the amount of DH during MPT, a decrease in inspiratory capacity (IC) or a change in IC as percentage of total lung capacity was used. No significant correlations were found between the parameters describing DH and PA. Secondary correlation analyses showed a negative correlation between static hyperinflation (SH) and PA (r = -0·39; P = 0·02). The pattern of breathing during MPT and the test itself showed high interpatient variability. The absence of a significant correlation between DH and PA is contrary to previous studies. SH did show a correlation with PA. The variety in results and the technical difficulties in execution of the measurements ask for a new, more reliable, method to detect DH and investigate its relation with PA in patients with COPD. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  14. Periods and light curves of 16 Cepheid variables in IC 1613 not completed by Baade

    International Nuclear Information System (INIS)

    Carlson, G.; Sandage, A.

    1990-01-01

    New periods and light curves are presented for 16 of the faintest Cepheids in IC 1613 which had not been finished by Baade. Magnitudes have been reduced to Freedman's new photometric scale. The P-L relation is extended to periods of 2 days using these new data. Comparison of the total Cepheid data now available in IC 1613 with the data in LMC shows no significant slope difference in the two P-L relations for periods of less than 10 days despite the lower metallicity of the young stars in IC 1613. Fifty new faint Cepheid candidates have been found in IC 1613 by blinking plates not used for this purpose by Baade. Most of these stars will have probable periods of less than 2 days, which will eventually permit an extension of the P-L relation in IC 1613 to fainter magnitudes when the photometry and period determinations are completed. 18 refs

  15. Watching AGN feedback at its birth: HST observations of nascent outflow host IC860

    Science.gov (United States)

    Alatalo, Katherine

    2016-10-01

    IC860 is a nearby IR-luminous early-type spiral with a unique set of properties: it is a shocked, poststarburst galaxy that hosts an AGN-driven neutral wind and a compact core of molecular gas. IC860 can serve as a rosetta stone for the early stages of triggering AGN feedback. We propose to use WFC3 on HST to obtain NUV, optical and near-IR imaging of IC860. We will create a spatially-resolved history of star formation quenching through SED-fitting of 7 requested broadband filters, and compare the spatially resolved star formation histories to in different positions within the underlying stellar features (such as spiral structure) that might define a narrative of how star formation is quenching in IC860. These observations will also resolve the super-star cluster sites to trace the most recent star formation. Finally, these observations will trace the mass of the outflow by building an absorption map of the dust. IC860 presents a unique opportunity to study a galaxy at an early stage of transitioning from blue spiral to red early-type galaxy, that also hosts an AGN-driven neutral wind and a compact, turbulent molecular gas core.

  16. Protecting ICS Systems Within the Energy Sector from Cyber Attacks

    Science.gov (United States)

    Barnes, Shaquille

    Advance persistent threat (APT) groups are continuing to attack the energy sector through cyberspace, which poses a risk to our society, national security, and economy. Industrial control systems (ICSs) are not designed to handle cyber-attacks, which is why asset owners need to implement the correct proactive and reactive measures to mitigate the risk to their ICS environments. The Industrial Control Systems Cyber Emergency Response Team (ICS-CERT) responded to 290 incidents for fiscal year 2016, where 59 of those incidents came from the Energy Sector. APT groups know how vulnerable energy sector ICS systems are and the destruction they can cause when they go offline such as loss of production, loss of life, and economic impact. Defending against APT groups requires more than just passive controls such as firewalls and antivirus solutions. Asset owners should implement a combination of best practices and active defense in their environment to defend against APT groups. Cyber-attacks against critical infrastructure will become more complex and harder to detect and respond to with traditional security controls. The purpose of this paper was to provide asset owners with the correct security controls and methodologies to help defend against APT groups.

  17. Scalable IC Platform for Smart Cameras

    Directory of Open Access Journals (Sweden)

    Harry Broers

    2005-08-01

    Full Text Available Smart cameras are among the emerging new fields of electronics. The points of interest are in the application areas, software and IC development. In order to reduce cost, it is worthwhile to invest in a single architecture that can be scaled for the various application areas in performance (and resulting power consumption. In this paper, we show that the combination of an SIMD (single-instruction multiple-data processor and a general-purpose DSP is very advantageous for the image processing tasks encountered in smart cameras. While the SIMD processor gives the very high performance necessary by exploiting the inherent data parallelism found in the pixel crunching part of the algorithms, the DSP offers a friendly approach to the more complex tasks. The paper continues to motivate that SIMD processors have very convenient scaling properties in silicon, making the complete, SIMD-DSP architecture suitable for different application areas without changing the software suite. Analysis of the changes in power consumption due to scaling shows that for typical image processing tasks, it is beneficial to scale the SIMD processor to use the maximum level of parallelism available in the algorithm if the IC supply voltage can be lowered. If silicon cost is of importance, the parallelism of the processor should be scaled to just reach the desired performance given the speed of the silicon.

  18. Definition of intercultural competence (IC) in undergraduate students at a private university in the USA: A mixed-methods study.

    Science.gov (United States)

    Gierke, Lioba; Binder, Nadine; Heckmann, Mark; Odağ, Özen; Leiser, Anne; Kedzior, Karina Karolina

    2018-01-01

    Intercultural competence (IC) is an important skill to be gained from higher education. However, it remains unclear what IC means to students and what factors might influence their definitions of IC. The aim of the current study was to qualitatively assess how students at one higher education institution in the USA define IC and to quantitatively test for relationships among IC components and various demographic characteristics, including intercultural experience and study context. A further aim was to descriptively compare the IC definitions from the US sample with the definitions obtained from another sample of university students in Germany. A purposive sample of n = 93 undergraduate, second semester students at Dickinson College, USA, participated in the study by completing an online questionnaire. The qualitative data were content-analyzed to define the dimensions of IC. The quantitative data were cluster-analyzed to assess the multivariate relationships among the IC components and the demographic characteristics of the sample. The most important dimensions of IC were Knowledge, External Outcomes (interaction, communication), and Attitudes (respect, tolerance) according to the US sample. The most frequently chosen dimensions of IC differed between both samples: Knowledge was chosen by the sample in the USA while External Outcomes was chosen by the sample in Germany. Relative to the US sample, significantly more students chose Attitudes, External Outcomes, and Intrapersonal Skills in the sample in Germany. The relationships among IC components and demographic characteristics were only weak in the US sample. A person with IC was rated as Open-minded and Respectful by students who lived predominantly in the USA or Tolerant and Curious by those who lived outside the USA for at least six months. The current results suggest that students residing in two countries (USA or Germany) define IC using similar dimensions. However, IC definitions may depend on the

  19. Analog IC Design at the University of Twente

    NARCIS (Netherlands)

    Nauta, Bram

    2007-01-01

    This article describes some recent research results from the IC Design group of the University of Twente, located in Enschede, The Netherlands. Our research focuses on analog CMOS circuit design with emphasis on high frequency and broadband circuits. With the trend of system integration in mind, we

  20. 30 CFR 57.22102 - Smoking (I-C mines).

    Science.gov (United States)

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Safety Standards for Methane in Metal and Nonmetal Mines Fire Prevention and Control § 57.22102 Smoking (I-C mines). (a...

  1. Prediction of post-operative pulmonary function after lobectomy for primary lung cancer: A comparison among counting method, effective lobar volume, and lobar collapsibility using inspiratory/expiratory CT

    Energy Technology Data Exchange (ETDEWEB)

    Yabuuchi, Hidetake, E-mail: h-yabu@med.kyushu-u.ac.jp [Department of Health Sciences, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan); Kawanami, Satoshi, E-mail: kawanami_01@mac.com [Department of Clinical Radiology, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan); Kamitani, Takeshi, E-mail: kamitani@radiol.med.kyushu-u.ac.jp [Department of Clinical Radiology, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan); Yonezawa, Masato, E-mail: ymasato@radiol.med.kyushu-u.ac.jp [Department of Clinical Radiology, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan); Yamasaki, Yuzo, E-mail: yyama@radiol.med.kyushu-u.ac.jp [Department of Clinical Radiology, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan); Yamanouchi, Torahiko, E-mail: tora0228jp@yahoo.co.jp [Department of Clinical Radiology, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan); Nagao, Michinobu, E-mail: minagao@radiol.med.kyushu-u.ac.jp [Department of Clinical Radiology, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan); Okamoto, Tatsuro, E-mail: tatsuro@surg2.med.kyushu-u.ac.jp [Department of Surgery and Science, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan); Honda, Hiroshi, E-mail: honda@radiol.med.kyushu-u.ac.jp [Department of Clinical Radiology, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan)

    2016-11-15

    Highlights: • ΔFEV{sub 1.0} and ppoΔFEV{sub 1.0} using lobar collapsibility were strongly correlated. • ΔVC and ppoΔVC using effective lobar volume were strongly correlated. • Counting method was inferior to lobar collapsibility for prediction of ppoFEV{sub 1.0}. • Inspiratory/expiratory CT is useful to predict post-operative pulmonary function. - Abstract: Purpose: To compare the predictabilities of postoperative pulmonary function after lobectomy for primary lung cancer among counting method, effective lobar volume, and lobar collapsibility. Methods: Forty-nine patients who underwent lobectomy for primary lung cancer were enrolled. All patients underwent inspiratory/expiratory CT and pulmonary function tests 2 weeks before surgery and postoperative pulmonary function tests 6–7 months after surgery. Pulmonary function losses (ΔFEV{sub 1.0} and ΔVC) were calculated from the pulmonary function tests. Predictive postoperative pulmonary function losses (ppoΔFEV{sub 1.0} and ppoΔVC) were calculated using counting method, effective volume, and lobar collapsibility. Correlations and agreements between ΔFEV{sub 1.0} and ppoFEV{sub 1.0} and those between ΔVC and ppoΔVC were tested among three methods using Spearman’s correlation coefficient and Bland-Altman plots. Results: ΔFEV{sub 1.0} and ppoΔFEV{sub 1.0insp-exp} were strongly correlated (r = 0.72), whereas ΔFEV{sub 1.0} and ppoΔFEV{sub 1.0count} and ΔFEV{sub 1.0} and Pred. ΔFEV{sub 1.0eff.vol.} were moderately correlated (r = 0.50, 0.56). ΔVC and ppoΔVC{sub eff.vol.} (r = 0.71) were strongly correlated, whereas ΔVC and ppoΔVC{sub count}, and ΔVC and ppoΔVC {sub insp-exp} were moderately correlated (r = 0.55, 0.42). Conclusions: Volumetry from inspiratory/expiratory CT data could be useful to predict postoperative pulmonary function after lobectomy for primary lung cancer.

  2. VizieR Online Data Catalog: Optical & Spitzer photometry in IC 1805 (Sung+, 2017)

    Science.gov (United States)

    Sung, H.; Bessell, M. S.; Chun, M.-Y.; Yi, J.; Naze, Y.; Lim, B.; Karimov, R.; Rauw, G.; Park, B.-G.; Hur, H.

    2017-06-01

    For a study of the IMF and the star-formation history of the young open cluster IC 1805, we obtained deep wide-field VRI and Hα images of IC 1805 using the CFH12K mosaic CCD camera of the CFHT on 2002 January 6 and 7. We also observed several regions in IC 1805, for a study of the reddening and massive star content, using the SITe 2000x800 CCD (Maidanak 2k CCD) and standard UBVRI filters of the AZT-22 1.5m telescope at the Maidanak Astronomical Observatory in Uzbekistan on 2003 August 18 and 2004 december 25,30. Later, we obtained additional images of the central region of IC 1805 with the Fairchild 486 CCD (SNUCam) and UBVI and Hα filters of the AZT-22 telescope on 2007 October 7 and 2009 January 19. The Spitzer mapping observations were performed on 2006 September 20 under program ID 20052 (PI: S. Wolff). For complete photometry of stars in the CFH12K FOV in 3.6 and 4.5um, we also downloaded and reduced the GLIMPSE360 data (AOR: 38753280, 38763264, 38769408, 38799104, 38798592, 38784512, PI: B. A. Whitney). MIPS scans of IC 1805 were obtained on 2005 August 31 and 2005 September 2 (PID 3234, PI: J. S. Greeves). The Chandra X-ray Observatory Observations of IC 1805 (ObsID: 7033, PI: L. Townley) were made on 2006 November 25. The total exposure time was about 79ks. The properties of 647 X-ray sources were published in Townsley+ (2014,J/ApJS/213/1). We searched for the optical and MIR counterparts of these X-ray sources with a matching radius of up to 1.5". (4 data files).

  3. Antioxidant capacity and bioactive compounds of four Brazilian native fruits.

    Science.gov (United States)

    Denardin, Cristiane C; Hirsch, Gabriela E; da Rocha, Ricardo F; Vizzotto, Márcia; Henriques, Amélia T; Moreira, José C F; Guma, Fátima T C R; Emanuelli, Tatiana

    2015-09-01

    The purpose of this study was to evaluate the bioactive compounds and antioxidant activity of extracts from araçá (Psidium cattleianum), butiá (Butia eriospatha), and pitanga (Eugenia uniflora) fruits with different flesh colors (i.e., purple, red, and orange), and blackberries (Rubus sp.; cv. Xavante and Cherokee) collected in the southern region of Brazil. The content of ascorbic acid, total carotenoids, and phenolics were determined. The profile of the phenolic compounds was assessed by high-performance liquid chromatography combined with diode array detection (HPLC-DAD). The antioxidant activity was determined using the ferric-reducing antioxidant power (FRAP) assay, 2,2-diphenyl-2-picrylhydrazyl hydrate (DPPH) assay, total reactive antioxidant potential (TRAP) assay, and total antioxidant reactivity (TAR) assay. The Xavante blackberry and purple-fleshed pitanga showed the highest total phenolic content [816.50 mg gallic acid equivalents (GAE)/100g and 799.80 mg GAE/100g, respectively]. The araçá and red-fleshed pitanga showed the highest carotenoid content (6.27 ug β-carotene/g and 5.86 ug β-carotene/g, respectively). The fruits contained several phenolic compounds such as quercetin derivatives, quercitrin, isoquercitrin, and cyanidin derivatives, which may contribute differentially to the antioxidant capacity. The highest scavenging activity in the DPPH assay was found for purple-fleshed pitanga (IC 50 36.78 mg/L), blackberries [IC 50 44.70 (Xavante) and IC 50 78.25 mg/L (Cherokee)], and araçá (IC 50 48.05 mg/L), which also showed the highest FRAP, followed by orange- and red-fleshed pitanga. Our results revealed that some fruits grown in southern Brazil such as purple-fleshed pitanga, blackberries, and araçá are rich sources of phenolic compounds and have great antioxidant activity. Copyright © 2015. Published by Elsevier B.V.

  4. Antioxidant capacity and bioactive compounds of four Brazilian native fruits

    Directory of Open Access Journals (Sweden)

    Cristiane C. Denardin

    2015-09-01

    Full Text Available The purpose of this study was to evaluate the bioactive compounds and antioxidant activity of extracts from araçá (Psidium cattleianum, butiá (Butia eriospatha, and pitanga (Eugenia uniflora fruits with different flesh colors (i.e., purple, red, and orange, and blackberries (Rubus sp.; cv. Xavante and Cherokee collected in the southern region of Brazil. The content of ascorbic acid, total carotenoids, and phenolics were determined. The profile of the phenolic compounds was assessed by high-performance liquid chromatography combined with diode array detection (HPLC-DAD. The antioxidant activity was determined using the ferric-reducing antioxidant power (FRAP assay, 2,2-diphenyl-2-picrylhydrazyl hydrate (DPPH assay, total reactive antioxidant potential (TRAP assay, and total antioxidant reactivity (TAR assay. The Xavante blackberry and purple-fleshed pitanga showed the highest total phenolic content [816.50 mg gallic acid equivalents (GAE/100g and 799.80 mg GAE/100g, respectively]. The araçá and red-fleshed pitanga showed the highest carotenoid content (6.27 ug β-carotene/g and 5.86 ug β-carotene/g, respectively. The fruits contained several phenolic compounds such as quercetin derivatives, quercitrin, isoquercitrin, and cyanidin derivatives, which may contribute differentially to the antioxidant capacity. The highest scavenging activity in the DPPH assay was found for purple-fleshed pitanga (IC50 36.78 mg/L, blackberries [IC50 44.70 (Xavante and IC50 78.25 mg/L (Cherokee], and araçá (IC50 48.05 mg/L, which also showed the highest FRAP, followed by orange- and red-fleshed pitanga. Our results revealed that some fruits grown in southern Brazil such as purple-fleshed pitanga, blackberries, and araçá are rich sources of phenolic compounds and have great antioxidant activity.

  5. Shocked molecular hydrogen in the supernova remnant IC 443

    International Nuclear Information System (INIS)

    Burton, M.G.; Brand, P.W.J.L.; Webster, A.S.

    1988-01-01

    Emission from the υ = 1-0 S(1) line of molecular hydrogen has been mapped over a section of the supernova remnant IC 443. The emission originates in a sinuous ridge where the expanding shell of the SNR is interacting with a molecular cloud. The relative intensities of the 1-0 S(1), 1-0 S(0) and 2-1 S(1) lines at 2.1-2.2 μm were measured and found to be characteristic of shock-excitation of the gas. The ridge shows bright spots which are possibly density enhancements in the molecular cloud. The total luminosity of the molecular hydrogen lines in the mapped region is estimated to be about 1000 times the solar luminosity, making IC 443 one of the most luminous galactic molecular hydrogen sources yet detected. (author)

  6. Some new results on shock chemistry in IC 443

    International Nuclear Information System (INIS)

    DeNoyer, L.K.; Frerking, M.A.

    1981-01-01

    We have made new observations of CO, 13 CO, SiO, SO, H 2 CO, HCO + , N 2 H + , CS, OCS, HCN, and OH in the shocked clouds of IC 443. At position IC 443 B, we find (a) the shocked CO is optically thin, (b) the HCO + /CO abundance ratio is 4--9 x 10 -4 , a tenfold enhancement over normal interstellar clouds, (c) HCN/CO = 1--3 x 10 -4 and CS/CO = 2--3 x 10 -4 , consistent with abundances found in ordinary clouds, (d) no enhancements of SO or SiO as occur in Orion KL, (e) optically thin preshock OH, confirming a hundredfold enhancement of OH/CO in the shock, and (f) an OH main line anomaly, with T/sub ex/(1667)>T/sub ex/(1665) in the shocked region

  7. A remotely-controlled locomotive IC driven by electrolytic bubbles and wireless powering.

    Science.gov (United States)

    Hsieh, Jian-Yu; Kuo, Po-Hung; Huang, Yi-Chun; Huang, Yu-Jie; Tsai, Rong-Da; Wang, Tao; Chiu, Hung-Wei; Wang, Yao-Hung; Lu, Shey-Shi

    2014-12-01

    A batteryless remotely-controlled locomotive IC utilizing electrolytic bubbles as propelling force is realized in 0.35 μm CMOS technology. Without any external components, such as magnets and on-board coils, the bare IC is wirelessly powered and controlled by a 10 MHz ASK modulated signal with RS232 control commands to execute movement in four moving directions and with two speeds. The receiving coil and electrolysis electrodes are all integrated on the locomotive chip. The experiment successfully demonstrated that the bare IC moved on the surface of an electrolyte with a speed up to 0.3 mm/s and change moving directions according to the commands. The total power consumptions of the chip are 207.4 μW and 180 μ W while the output electrolysis voltages are 2 V and 1.3 V, respectively.

  8. Effect of volume-oriented versus flow-oriented incentive spirometry on chest wall volumes, inspiratory muscle activity, and thoracoabdominal synchrony in the elderly.

    Science.gov (United States)

    Lunardi, Adriana C; Porras, Desiderio C; Barbosa, Renata Cc; Paisani, Denise M; Marques da Silva, Cibele C B; Tanaka, Clarice; Carvalho, Celso R F

    2014-03-01

    Aging causes physiological and functional changes that impair pulmonary function. Incentive spirometry is widely used for lung expansion, but the effects of volume-oriented incentive spirometry (VIS) versus flow-oriented incentive spirometry (FIS) on chest wall volumes, inspiratory muscle activity, and thoracoabdominal synchrony in the elderly are poorly understood. We compared VIS and FIS in elderly subjects and healthy adult subjects. Sixteen elderly subjects (9 women, mean ± SD age 70.6 ± 3.9 y, mean ± SD body mass index 23.8 ± 2.5 kg/m(2)) and 16 healthy adults (8 women, mean ± age 25.9 ± 4.3 y, mean ± body mass index 23.6 ± 2.4 kg/m(2)) performed quiet breathing, VIS, and FIS in randomized sequence. Chest wall kinematics (via optoelectronic plethysmography) and inspiratory muscle activity (via surface electromyography) were assessed simultaneously. Synchrony between the superior thorax and abdominal motion was calculated (phase angle). In the elderly subjects both types of incentive spirometry increased chest wall volumes similarly, whereas in the healthy adult subjects VIS increased the chest wall volume more than did FIS. FIS and VIS triggered similar lower thoracoabdominal synchrony in the elderly subjects, whereas in the healthy adults FIS induced lower synchrony than did VIS. FIS required more muscle activity in the elderly subjects to create an increase in chest wall volume. Incentive spirometry performance is influenced by age, and the differences between elderly and healthy adults response should be considered in clinical practice.

  9. Spitzer Observations Of IC 2118

    Science.gov (United States)

    2010-09-01

    Micron All-Sky Survey ( 2MASS ; Skrutskie et al. 2006) photometric data in an effort to segregate YSOs from background galaxies. While one previously known T...Spectral Typea Other names IRAS 04591−0856 05 01 30.2 −08 52 14 . . . HHL 17, G13 2MASS 05020630−0850467 05 02 06.3 −08 50 47 M2 IV . . . RXJ 0502.4−0744b...05 02 20.8 −07 44 10 . . . 2MASS 05022084−0744099 2MASS 05060574−0646151c 05 06 05.7 −06 46 15 G8: (May not be a member of IC 2118; see Kun et al

  10. Intellectual Capital (IC Analysis and The Effect to Financial Performance in PT Kalasuba Indonesia (KSI

    Directory of Open Access Journals (Sweden)

    Dwi Ermayanti Susilo

    2016-10-01

    Full Text Available Financial Performance (FP is one of the important things for a company to know the development of the company. One important thing that influences FP is the Intellectual Capital (IC. Research was conducted to get the best IC analysis in order to get success and fulfill the daily human needs which always increases. Therefore, it had research problem ‘how was the components of IC affecting the FP of PT Kalasuba Indonesia (KSI, and the objective is to explore the IC components in affecting the FP. It was interesting to be explored because it had unique characteristics, which consist of spiritual knowledge, attitude, discipline, management knowledge and managerial experience, as well as skill and capabilities, in which the first three points were different from the rest. It used qualitative analysis method as the instrument. It was done by collecting the data through observation and was analyzed using the Robbins theory. It can be concluded that those five IC has important effect in increasing FP of PT KSI and keeping it stable.

  11. Benefits of combined aerobic/resistance/inspiratory training in patients with chronic heart failure. A complete exercise model? A prospective randomised study.

    Science.gov (United States)

    Laoutaris, Ioannis D; Adamopoulos, Stamatis; Manginas, Athanassios; Panagiotakos, Demosthenes B; Kallistratos, Manolis S; Doulaptsis, Costas; Kouloubinis, Alexandros; Voudris, Vasilis; Pavlides, Gregory; Cokkinos, Dennis V; Dritsas, Athanasios

    2013-09-01

    We hypothesised that combined aerobic training (AT) with resistance training (RT) and inspiratory muscle training (IMT) could result in additional benefits over AT alone in patients with chronic heart failure (CHF). Twenty-seven patients, age 58 ± 9 years, NYHA II/III and LVEF 29 ± 7% were randomly assigned to a 12-week AT (n=14) or a combined AT/RT/IMT (ARIS) (n=13) exercise program. AT consisted of bike exercise at 70-80% of max heart rate. ARIS training consisted of AT with RT of the quadriceps at 50% of 1 repetition maximum (1RM) and upper limb exercises using dumbbells of 1-2 kg as well as IMT at 60% of sustained maximal inspiratory pressure (SPI(max)). At baseline and after intervention patients underwent cardiopulmonary exercise testing, echocardiography, evaluation of dyspnea, muscle function and quality of life (QoL) scores. The ARIS program as compared to AT alone, resulted in additional improvement in quadriceps muscle strength (1RM, p=0.005) and endurance (50%1 RM × number of max repetitions, p=0.01), SPI(max) (pexercise time (p=0.01), circulatory power (peak oxygen consumption × peak systolic blood pressure, p=0.05), dyspnea (p=0.03) and QoL (p=0.03). ARIS training was safe and resulted in incremental benefits in both peripheral and respiratory muscle weakness, cardiopulmonary function and QoL compared to that of AT. The present findings may add a new prospective to cardiac rehabilitation programs of heart failure patients whilst the clinical significance of these outcomes need to be addressed in larger randomised studies. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  12. Monitoring System for Slope Stability under Rainfall by using MEMS Acceleration Sensor IC tags

    International Nuclear Information System (INIS)

    Murakami, S; Dairaku, A; Komine, H; Saito, O; Sakai, N; Isizawa, T; Maruyama, I

    2013-01-01

    Real-time warning system for slope failure under rainfall is available to disaster prevention and mitigation. Monitoring of multi-point and wireless measurements is effective because it is difficult to conclude the most dangerous part in a slope. The purpose of this study is to propose a method of monitoring system with multi-point and wireless measurements for a slope stability using MEMS acceleration sensor IC tags. MEMS acceleration sensor IC tag is an acceleration sensor microminiaturized by a technology of Micro Electro Mechanical Systems on board IC tag. Especially, low cost of the sensor will yield to the realization of the system. In order to investigate the applicability of the proposed system, a large-scale model test of artificial slope subjected to rainfall has been performed. MEMS acceleration sensor IC tags has been located on the slope and ground acceleration caused by forced vibration has been measured until the model slope collapses. The experimental results show that the MEMS acceleration sensor IC tag is comfortably available under rainfall, the characteristics of ground accelerations varies with changing the condition of the slope subjected to rainfall, and the proposed method can be applied to a real-time monitoring system for slope failure under rainfall.

  13. A SPECTROSCOPICALLY NORMAL TYPE Ic SUPERNOVA FROM A VERY MASSIVE PROGENITOR

    International Nuclear Information System (INIS)

    Valenti, Stefano; Pastorello, Andrea; Benetti, Stefano; Cappellaro, Enrico; Tomasella, Lina; Turatto, Massimo; Taubenberger, Stefan; Aramyan, Levon; Botticella, Maria Teresa; Fraser, Morgan; Smartt, Stephen J.; Magill, Lindsay; Kotak, Rubina; Wright, Darryl E.; Elias-Rosa, Nancy; Ergon, Mattias; Sollerman, Jesper; Magnier, Eugene; Price, Paul A.

    2012-01-01

    We present observations of the Type Ic supernova (SN Ic) 2011bm spanning a period of about one year. The data establish that SN 2011bm is a spectroscopically normal SN Ic with moderately low ejecta velocities and with a very slow spectroscopic and photometric evolution (more than twice as slow as SN 1998bw). The Pan-STARRS1 retrospective detection shows that the rise time from explosion to peak was ∼40 days in the R band. Through an analysis of the light curve and the spectral sequence, we estimate a kinetic energy of ∼7-17 foe and a total ejected mass of ∼7-17 M ☉ , 5-10 M ☉ of which is oxygen and 0.6-0.7 M ☉ is 56 Ni. The physical parameters obtained for SN 2011bm suggest that its progenitor was a massive star of initial mass 30-50 M ☉ . The profile of the forbidden oxygen lines in the nebular spectra shows no evidence of a bi-polar geometry in the ejected material.

  14. Stress Voiding in IC Interconnects - Rules of Evidence for Failure Analysts

    Energy Technology Data Exchange (ETDEWEB)

    FILTER, WILLIAM F.

    1999-09-17

    Mention the words ''stress voiding'', and everyone from technology engineer to manager to customer is likely to cringe. This IC failure mechanism elicits fear because it is insidious, capricious, and difficult to identify and arrest. There are reasons to believe that a damascene-copper future might be void-free. Nevertheless, engineers who continue to produce ICs with Al-alloy interconnects, or who assess the reliability of legacy ICs with long service life, need up-to-date insights and techniques to deal with stress voiding problems. Stress voiding need not be fearful. Not always predictable, neither is it inevitable. On the contrary, stress voids are caused by specific, avoidable processing errors. Analytical work, though often painful, can identify these errors when stress voiding occurs, and vigilance in monitoring the improved process can keep it from recurring. In this article, they show that a methodical, forensics approach to failure analysis can solve suspected cases of stress voiding. This approach uses new techniques, and patiently applies familiar ones, to develop evidence meeting strict standards of proof.

  15. Physical IC debug ─ backside approach and nanoscale challenge

    Directory of Open Access Journals (Sweden)

    U. Kerst

    2008-05-01

    Full Text Available Physical analysis for IC functionality in submicron technologies requires access through chip backside. Based upon typical global backside preparation with 50–100 µm moderate silicon thickness remaining, a state of the art of the analysis techniques available for this purpose is presented and evaluated for functional analysis and layout pattern resolution potential. A circuit edit technique valid for nano technology ICs, is also presented that is based upon the formation of local trenches using the bottom of Shallow Trench Isolation (STI as endpoint for Focused Ion Beam (FIB milling. As a derivative from this process, a locally ultra thin silicon device can be processed, creating a back surface as work bench for breakthrough applications of nanoscale analysis techniques to a fully functional circuit through chip backside. Several applications demonstrate the power and potential of this new approach.

  16. ASD IC for the thin gap chambers in the LHC Atlas experiment

    International Nuclear Information System (INIS)

    Sasaki, Osamu; Yoshida, Mitsuhiro

    1999-01-01

    An amplifier-shaper-discriminator (ASD) chip was designed and built for Thin Gap Chambers in the forward muon trigger system of the LHC Atlas experiment. The ASD IC uses SONY Analog Master Slice bipolar technology. The IC contains 4 channels in a QFP48 package. The gain of its first stage (preamplifier) is approximately 0.8V/pC and output from the preamplifier is received by a shaper (main-amplifier) with a gain of 7. The baseline restoration circuit is incorporated in the main-amplifier. The threshold voltage for discriminator section is common to the 4 channels and their digital output level is LVDS-compatible. The IC also has analog output of the preamplifier. The equivalent noise charge at input capacitance of 150 pF is around 7,500 electrons. The power dissipation with LDVS outputs (100 Omega load) is 59mW/ch

  17. ASD IC for the thin gap chambers in the LHC ATLAS experiment

    CERN Document Server

    Sasaki, O

    1998-01-01

    An amplifier-shaper-discriminator (ASD) chip was designed and built for Thin Gap Chambers in the forward muon trigger system of the LHC ATLAS experiment. The ASD IC uses SONY Analog Master Slice bipolar technology. The IC contains 4 $9 channels in a QFP48 package. The gain of its first stage (preamplifier) is approximately 0.8 V/pC and output from the preamplifier is received by a shaper (main-amplifier) with a gain of 7. The baseline restoration circuit is $9 incorporated in the main-amplifier. The threshold voltage for the discriminator section is common to the 4 channels and their digital output level is LVDS-compatible. The IC also has analog output for the preamplifier. The equivalent $9 noise charge at input capacitance of 150 pF is around 7500 electrons. The power dissipation with LDVS outputs (100 Omega load) is 59 mW/ch. (8 refs).

  18. ASD IC for the thin gap chambers in the LHC ATLAS Experiment

    CERN Document Server

    Sasaki, O

    1999-01-01

    An amplifier-shaper-discriminator (ASD) chip was designed and built for Thin Gap Chambers in the forward muon trigger system of the LHC Atlas experiment. The ASD IC uses SONY Analog Master Slice bipolar technology. The IC contains 4 channels in a QFP48 package. The gain of its first stage (preamplifier) is approximately 0.8 V/pC and output from the preamplifier is received by a shaper (main-amplifier) with a gain of 7. The baseline restoration circuit is incorporated in the main-amplifier. The threshold voltage for discriminator section is common to the 4 channels and their digital output level is LVDS- compatible. The IC also has analog output of the preamplifier. The equivalent noise charge at input capacitance of 150 pF is around 7500 electrons. The power dissipation with LDVS outputs (100 Omega load) is 59 mW/ch.

  19. AREVA advanced safety IC solutions and licensing experience for new nuclear builds and modernization projects - 15545

    International Nuclear Information System (INIS)

    Fourestie, B.; Pickelmann, J.; Richter, S.; Hilsenkopf, P.; Paris, P.

    2015-01-01

    Regulatory requirements for the Instrumentation and Control (IC) for Nuclear Power Plants have become significantly more stringent during the last 10 years in the areas of software development and qualification, traceability, diversity, or seismic requirements for instance, and with the introduction of new standards (such as the IEC 62566, or the IEC 62003). Based on a large and comprehensive experience gained from projects in several regulatory environments and different plant types (including non-OEM plants), AREVA has developed and adapted its processes and products to provide state-of-the-art IC solutions in full compliance with the regulatory demands and requirements in terms of robustness (independence, defense-in-depth, diversity and cyber-security). In this paper we present the safety IC platforms developed by AREVA. These platforms include TELEPERM XS as the computerized safety IC platform for class 1 system implementation, the Qualified Display System (QDS) for safety classified screen-based interface, and UNICORN as fully diverse analog safety IC platform for backup systems

  20. Increased bladder wall thickness is associated with severe symptoms and reduced bladder capacity in patients with bladder pain syndrome

    Directory of Open Access Journals (Sweden)

    Shu-Yu Wu

    2016-12-01

    Conclusion: There are obvious differences in bladder CT scans of patients with symptoms of bladder pain due to different etiology. Increased BWT was associated with increased pain scores and decreased bladder capacity in patients with KC and IC. BWT on a CT scan might be considered a marker for the severity of bladder inflammation.

  1. SN 2017dio: A Type-Ic Supernova Exploding in a Hydrogen-rich Circumstellar Medium

    Science.gov (United States)

    Kuncarayakti, Hanindyo; Maeda, Keiichi; Ashall, Christopher J.; Prentice, Simon J.; Mattila, Seppo; Kankare, Erkki; Fransson, Claes; Lundqvist, Peter; Pastorello, Andrea; Leloudas, Giorgos; Anderson, Joseph P.; Benetti, Stefano; Bersten, Melina C.; Cappellaro, Enrico; Cartier, Régis; Denneau, Larry; Della Valle, Massimo; Elias-Rosa, Nancy; Folatelli, Gastón; Fraser, Morgan; Galbany, Lluís; Gall, Christa; Gal-Yam, Avishay; Gutiérrez, Claudia P.; Hamanowicz, Aleksandra; Heinze, Ari; Inserra, Cosimo; Kangas, Tuomas; Mazzali, Paolo; Melandri, Andrea; Pignata, Giuliano; Rest, Armin; Reynolds, Thomas; Roy, Rupak; Smartt, Stephen J.; Smith, Ken W.; Sollerman, Jesper; Somero, Auni; Stalder, Brian; Stritzinger, Maximilian; Taddia, Francesco; Tomasella, Lina; Tonry, John; Weiland, Henry; Young, David R.

    2018-02-01

    SN 2017dio shows both spectral characteristics of a type-Ic supernova (SN) and signs of a hydrogen-rich circumstellar medium (CSM). Prominent, narrow emission lines of H and He are superposed on the continuum. Subsequent evolution revealed that the SN ejecta are interacting with the CSM. The initial SN Ic identification was confirmed by removing the CSM interaction component from the spectrum and comparing with known SNe Ic and, reversely, adding a CSM interaction component to the spectra of known SNe Ic and comparing them to SN 2017dio. Excellent agreement was obtained with both procedures, reinforcing the SN Ic classification. The light curve constrains the pre-interaction SN Ic peak absolute magnitude to be around {M}g=-17.6 mag. No evidence of significant extinction is found, ruling out a brighter luminosity required by an SN Ia classification. These pieces of evidence support the view that SN 2017dio is an SN Ic, and therefore the first firm case of an SN Ic with signatures of hydrogen-rich CSM in the early spectrum. The CSM is unlikely to have been shaped by steady-state stellar winds. The mass loss of the progenitor star must have been intense, \\dot{M}∼ 0.02{({ε }{{H}α }/0.01)}-1 ({v}{wind}/500 km s‑1) ({v}{shock}/10,000 km s‑1)‑3 M ⊙ yr‑1, peaking at a few decades before the SN. Such a high mass-loss rate might have been experienced by the progenitor through eruptions or binary stripping. Based on observations made with the NOT, operated by the Nordic Optical Telescope Scientific Association at the Observatorio del Roque de los Muchachos, La Palma, Spain, of the Instituto de Astrofisica de Canarias. This work is based (in part) on observations collected at the European Organisation for Astronomical Research in the Southern Hemisphere, Chile as part of PESSTO, (the Public ESO Spectroscopic Survey for Transient Objects Survey) ESO program 188.D-3003, 191.D-0935, 197.D-1075. Based on observations made with the Liverpool Telescope operated on the

  2. Postoperative inspiratory muscle training in addition to breathing exercises and early mobilization improves oxygenation in high-risk patients after lung cancer surgery: a randomized controlled trial.

    Science.gov (United States)

    Brocki, Barbara Cristina; Andreasen, Jan Jesper; Langer, Daniel; Souza, Domingos Savio R; Westerdahl, Elisabeth

    2016-05-01

    The aim was to investigate whether 2 weeks of inspiratory muscle training (IMT) could preserve respiratory muscle strength in high-risk patients referred for pulmonary resection on the suspicion of or confirmed lung cancer. Secondarily, we investigated the effect of the intervention on the incidence of postoperative pulmonary complications. The study was a single-centre, parallel-group, randomized trial with assessor blinding and intention-to-treat analysis. The intervention group (IG, n = 34) underwent 2 weeks of postoperative IMT twice daily with 2 × 30 breaths on a target intensity of 30% of maximal inspiratory pressure, in addition to standard postoperative physiotherapy. Standard physiotherapy in the control group (CG, n = 34) consisted of breathing exercises, coughing techniques and early mobilization. We measured respiratory muscle strength (maximal inspiratory/expiratory pressure, MIP/MEP), functional performance (6-min walk test), spirometry and peripheral oxygen saturation (SpO2), assessed the day before surgery and again 3-5 days and 2 weeks postoperatively. Postoperative pulmonary complications were evaluated 2 weeks after surgery. The mean age was 70 ± 8 years and 57.5% were males. Thoracotomy was performed in 48.5% (n = 33) of cases. No effect of the intervention was found regarding MIP, MEP, lung volumes or functional performance at any time point. The overall incidence of pneumonia was 13% (n = 9), with no significant difference between groups [IG 6% (n = 2), CG 21% (n = 7), P = 0.14]. An improved SpO2 was found in the IG on the third and fourth postoperative days (Day 3: IG 93.8 ± 3.4 vs CG 91.9 ± 4.1%, P = 0.058; Day 4: IG 93.5 ± 3.5 vs CG 91 ± 3.9%, P = 0.02). We found no association between surgical procedure (thoracotomy versus thoracoscopy) and respiratory muscle strength, which was recovered in both groups 2 weeks after surgery. Two weeks of additional postoperative IMT, compared with standard physiotherapy alone, did not preserve

  3. Current issues in the respiratory care of patients with amyotrophic lateral sclerosis

    Directory of Open Access Journals (Sweden)

    Marco Orsini

    2015-10-01

    Full Text Available Amyotrophic lateral sclerosis is a progressive neuromuscular disease, resulting in respiratory muscle weakness, reduced pulmonary volumes, ineffective cough, secretion retention, and respiratory failure. Measures as vital capacity, maximal inspiratory and expiratory pressures, sniff nasal inspiratory pressure, cough peak flow and pulse oximetry are recommended to monitor the respiratory function. The patients should be followed up by a multidisciplinary team, focused in improving the quality of life and deal with the respiratory symptoms. The respiratory care approach includes airway clearance techniques, mechanically assisted cough and noninvasive mechanical ventilation. Vaccination and respiratory pharmacological support are also recommended. To date, there is no enough evidence supporting the inspiratory muscle training and diaphragmatic pacing.

  4. Revealing the nebular properties and Wolf-Rayet population of IC10 with Gemini/GMOS

    Science.gov (United States)

    Tehrani, Katie; Crowther, Paul A.; Archer, I.

    2017-12-01

    We present a deep imaging and spectroscopic survey of the Local Group irregular galaxy IC10 using Gemini North and GMOS to unveil its global Wolf-Rayet (WR) population. We obtain a star formation rate (SFR) of 0.045 ± 0.023 M⊙ yr-1, for IC10 from the nebular H α luminosity, which is comparable to the Small Magellanic Cloud. We also present a revised nebular oxygen abundance of log(O/H) + 12 = 8.40 ± 0.04, comparable to the LMC. It has previously been suggested that for IC10 to follow the WR subtype-metallicity dependance seen in other Local Group galaxies, a large WN population awaits discovery. Our search revealed three new WN stars, and six candidates awaiting confirmation, providing little evidence to support this claim. The new global WR star total of 29 stars is consistent with the Large Magellanic Cloud population when scaled to the reduced SFR of IC10. For spectroscopically confirmed WR stars, the WC/WN ratio is lowered to 1.0; however, including all potential candidates, and assuming those unconfirmed to be WN stars, would reduce the ratio to ∼0.7. We attribute the high WC/WN ratio to the high star formation surface density of IC10 relative to the Magellanic Clouds, which enhances the frequency of high-mass stars capable of producing WC stars.

  5. Electron Storage Ring Development for ICS Sources

    Energy Technology Data Exchange (ETDEWEB)

    Loewen, Roderick [Lyncean Technologies, Inc., Palo Alto, CA (United States)

    2015-09-30

    There is an increasing world-wide interest in compact light sources based on Inverse Compton Scattering. Development of these types of light sources includes leveraging the investment in accelerator technology first developed at DOE National Laboratories. Although these types of light sources cannot replace the larger user-supported synchrotron facilities, they offer attractive alternatives for many x-ray science applications. Fundamental research at the SLAC National Laboratory in the 1990’s led to the idea of using laser-electron storage rings as a mechanism to generate x-rays with many properties of the larger synchrotron light facilities. This research led to a commercial spin-off of this technology. The SBIR project goal is to understand and improve the performance of the electron storage ring system of the commercially available Compact Light Source. The knowledge gained from studying a low-energy electron storage ring may also benefit other Inverse Compton Scattering (ICS) source development. Better electron storage ring performance is one of the key technologies necessary to extend the utility and breadth of applications of the CLS or related ICS sources. This grant includes a subcontract with SLAC for technical personnel and resources for modeling, feedback development, and related accelerator physics studies.

  6. μ opioid receptor activation hyperpolarizes respiratory-controlling Kölliker-Fuse neurons and suppresses post-inspiratory drive.

    Science.gov (United States)

    Levitt, Erica S; Abdala, Ana P; Paton, Julian F R; Bissonnette, John M; Williams, John T

    2015-10-01

    In addition to reductions in respiratory rate, opioids also cause aspiration and difficulty swallowing, indicating impairment of the upper airways. The Kölliker-Fuse (KF) maintains upper airway patency and a normal respiratory pattern. In this study, activation of μ opioid receptors in the KF reduced respiratory frequency and tidal volume in anaesthetized rats. Nerve recordings in an in situ preparation showed that activation of μ opioid receptors in the KF eliminated the post-inspiration phase of the respiratory cycle. In brain slices, μ opioid agonists hyperpolarized a distinct population (61%) of KF neurons by activation of an inwardly rectifying potassium conductance. These results suggest that KF neurons that are hyperpolarized by opioids could contribute to opioid-induced respiratory disturbances, particularly the impairment of upper airways. Opioid-induced respiratory effects include aspiration and difficulty swallowing, suggesting impairment of the upper airways. The pontine Kölliker-Fuse nucleus (KF) controls upper airway patency and regulates respiration, in particular the inspiratory/expiratory phase transition. Given the importance of the KF in coordinating respiratory pattern, the mechanisms of μ opioid receptor activation in this nucleus were investigated at the systems and cellular level. In anaesthetized, vagi-intact rats, injection of opioid agonists DAMGO or [Met(5) ]enkephalin (ME) into the KF reduced respiratory frequency and amplitude. The μ opioid agonist DAMGO applied directly into the KF of the in situ arterially perfused working heart-brainstem preparation of rat resulted in robust apneusis (lengthened low amplitude inspiration due to loss of post-inspiratory drive) that was rapidly reversed by the opioid antagonist naloxone. In brain slice preparations, activation of μ opioid receptors on KF neurons hyperpolarized a distinct population (61%) of neurons. As expected, the opioid-induced hyperpolarization reduced the excitability of

  7. [Effects of an inpatient pulmonary rehabilitation program on dyspnea, exercise capacity, and health related quality of life for patients with chronic lung disease].

    Science.gov (United States)

    Lee, Chang Kwan

    2007-04-01

    The purpose of this study was to examine the effects of an inpatient pulmonary rehabilitation program on dyspnea, exercise capacity, and health related quality of life in inpatients with chronic lung disease. This quasi experimental study was designed with a nonequivalent control group pre-post test time series. Twenty three patients were assigned to the experimental group and nineteen to the control group. The inpatient pulmonary rehabilitation program was composed of upper and lower extremity exercise, breathing retraining, inspiratory muscle training, education, relaxation and telephone contacts. This program consisted of 4 sessions with inpatients and 4 weeks at home after discharge. The control group was given a home based pulmonary rehabilitation program at the time of discharge. The outcomes were measured by the Borg score, 6MWD and the Chronic Respiratory Disease Questionnaire(CRQ). There was a statistically significant difference in dyspnea between the experimental group and control group, but not among time sequence, or interaction between groups and time sequence. Also significant improvements in exercise capacity and health related quality of life were found only in the experimental group. An Inpatient pulmonary rehabilitation program may be a useful intervention to reduce dyspnea, and increase exercise capacity and health related quality of life for chronic lung disease patients.

  8. Static and dynamic hyperinflation during severe acute exacerbations of chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    van Geffen WH

    2018-04-01

    Full Text Available Wouter H van Geffen,1,2 Huib AM Kerstjens2 1Department of Respiratory Medicine, Medical Centre Leeuwarden, Leeuwarden, the Netherlands; 2Department of Pulmonary Diseases, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands Background: Static hyperinflation is known to be increased during moderate acute exacerbations of chronic obstructive pulmonary disease (COPD (AECOPD, but few data exist in patients with severe exacerbations of COPD. The role of dynamic hyperinflation during exacerbations is unclear. Methods: In a prospective, observational cohort study, we recruited patients admitted to hospital for AECOPD. The following measurements were performed upon admission and again after resolution (stable state at least 42 days later: inspiratory capacity (IC, body plethysmography, dynamic hyperinflation by metronome-paced IC measurement, health-related quality of life and dyspnea. Results: Forty COPD patients were included of whom 28 attended follow-up. The IC was low at admission (2.05±0.11 L and increased again during resolution by 15.6%±23.1% or 0.28±0.08 L (mean ± standard error of the mean, p<0.01. Testing of metronome-paced changes in IC was feasible, and it decreased by 0.74±0.06 L at admission, similarly to at stable state. Clinical COPD Questionnaire score was 3.7±0.2 at admission and improved by 1.7±0.2 points (p<0.01, and the Borg dyspnea score improved by 2.2±0.5 points from 4.4±0.4 at admission (p<0.01. Conclusion: Static hyperinflation is increased during severe AECOPD requiring hospitalization compared with stable state. We could measure metronome-paced dynamic hyperinflation during severe AECOPD but found no increase. Keywords: COPD, exacerbations of COPD, static hyperinflation, dynamic hyperinflation, severe acute exacerbations of COPD, COPD exacerbation, chronic obstructive pulmonary disease

  9. Intraluminal Administration of Poly I:C Causes an Enteropathy That Is Exacerbated by Administration of Oral Dietary Antigen

    Science.gov (United States)

    Araya, Romina E.; Jury, Jennifer; Bondar, Constanza

    2014-01-01

    Systemic administration of polyinosinic:polycytidylic acid (poly I:C), mimics virally-induced activation of TLR3 signalling causing acute small intestine damage, but whether and how mucosal administration of poly I:C causes enteropathy is less clear. Our aim was to investigate the inflammatory pathways elicited after intraluminal administration of poly I:C and determine acute and delayed consequences of this locally induced immune activation. Intraluminal poly I:C induced rapid mucosal immune activation in C57BL/6 mice involving IFNβ and the CXCL10/CXCR3 axis, that may drive inflammation towards a Th1 profile. Intraluminal poly I:C also caused enteropathy and gut dysfunction in gliadin-sensitive NOD-DQ8 mice, and this was prolonged by concomitant oral administration of gliadin. Our results indicate that small intestine pathology can be induced in mice by intraluminal administration of poly I:C and that this is exacerbated by subsequent oral delivery of a relevant dietary antigen. PMID:24915573

  10. The Approximate Capacity Region of the Symmetric $K$-user Gaussian Interference Channel with Strong Interference

    KAUST Repository

    Chaaban, Anas

    2016-03-01

    The symmetric K-user interference channel is studied with the goal of characterizing its capacity region in the strong interference regime within a constant gap. The achievable rate region of a scheme combining rate-splitting at the transmitters and interference alignment and successive decoding/computation at the receivers is derived. Next it is shown that this scheme achieves the so-called greedy-max corner points of the capacity region within a constant gap. By combining this result with previous results by Ordentlich et al. on the sum-capacity of the symmetric interference channel, a constant gap characterization of the capacity region for the strong interference regime is obtained. This leads to the first approximate characterization of the capacity region of the symmetric K-user IC. Furthermore, a new scheme that achieves the sum-capacity of the channel in the strong interference regime within a constant gap is also proposed, and the corresponding gap is calculated. The advantage of the new scheme is that it leads to a characterization within a constant gap without leaving an outage set contrary to the scheme by Ordentlich et al..

  11. The Approximate Capacity Region of the Symmetric $K$-user Gaussian Interference Channel with Strong Interference

    KAUST Repository

    Chaaban, Anas; Sezgin, Aydin

    2016-01-01

    The symmetric K-user interference channel is studied with the goal of characterizing its capacity region in the strong interference regime within a constant gap. The achievable rate region of a scheme combining rate-splitting at the transmitters and interference alignment and successive decoding/computation at the receivers is derived. Next it is shown that this scheme achieves the so-called greedy-max corner points of the capacity region within a constant gap. By combining this result with previous results by Ordentlich et al. on the sum-capacity of the symmetric interference channel, a constant gap characterization of the capacity region for the strong interference regime is obtained. This leads to the first approximate characterization of the capacity region of the symmetric K-user IC. Furthermore, a new scheme that achieves the sum-capacity of the channel in the strong interference regime within a constant gap is also proposed, and the corresponding gap is calculated. The advantage of the new scheme is that it leads to a characterization within a constant gap without leaving an outage set contrary to the scheme by Ordentlich et al..

  12. Mathematical and Simulation Modelling of Moisture Diffusion Mechanism during Plastic IC Packages Disassembly

    Directory of Open Access Journals (Sweden)

    Peng Mou

    2013-01-01

    Full Text Available Reuse of plastic IC packages disassembled from printed circuit boards (PCBs has significant environmental benefits and economic value. The interface delamination caused by moisture diffusion is the main failure mode of IC packages during the disassembling process, which greatly reduces the reusability and reliability of disassembled IC packages. Exploring moisture diffusion mechanism is a prerequisite to optimize prebaking processes before disassembling that is an effective way to avoid the interface delamination. To this end, a computational model with variable boundary conditions is developed based on the different combination state of water in IC packages. The distribution characteristics and mechanism of moisture diffusion behavior are analyzed including the humidity distribution field and the relation among baking temperature, water loss rate, and baking time during baking process, and then the results are validated by FEA simulation based on the improved definition of relative moisture concentration. Baking under variable temperature is proposed and compared with the baking process and baking efficiency under constant temperature to find out the optimized baking parameters. Finally, a set of curves which indicate the relation between baking energy consumption and temperature are determined under actual industrial baking experiments, which could be used as references to develop industrial standards for PCB disassembling process.

  13. Lung Function before and Two Days after Open-Heart Surgery

    Directory of Open Access Journals (Sweden)

    Charlotte Urell

    2012-01-01

    Full Text Available Reduced lung volumes and atelectasis are common after open-heart surgery, and pronounced restrictive lung volume impairment has been found. The aim of this study was to investigate factors influencing lung volumes on the second postoperative day. Open-heart surgery patients (n=107, 68 yrs, 80% male performed spirometry both before surgery and on the second postoperative day. The factors influencing postoperative lung volumes and decrease in lung volumes were investigated with univariate and multivariate analyses. Associations between pain (measured by numeric rating scale and decrease in postoperative lung volumes were calculated with Spearman rank correlation test. Lung volumes decreased by 50% and were less than 40% of the predictive values postoperatively. Patients with BMI >25 had lower postoperative inspiratory capacity (IC (33±14% pred. than normal-weight patients (39±15% pred., (P=0.04. More pain during mobilisation was associated with higher decreases in postoperative lung volumes (VC: r=0.33, P=0.001; FEV1: r=0.35, P≤0.0001; IC: r=0.25, P=0.01. Patients with high BMI are a risk group for decreased postoperative lung volumes and should therefore receive extra attention during postoperative care. As pain is related to a larger decrease in postoperative lung volumes, optimal pain relief for the patients should be identified.

  14. Lung Function before and Two Days after Open-Heart Surgery.

    Science.gov (United States)

    Urell, Charlotte; Westerdahl, Elisabeth; Hedenström, Hans; Janson, Christer; Emtner, Margareta

    2012-01-01

    Reduced lung volumes and atelectasis are common after open-heart surgery, and pronounced restrictive lung volume impairment has been found. The aim of this study was to investigate factors influencing lung volumes on the second postoperative day. Open-heart surgery patients (n = 107, 68 yrs, 80% male) performed spirometry both before surgery and on the second postoperative day. The factors influencing postoperative lung volumes and decrease in lung volumes were investigated with univariate and multivariate analyses. Associations between pain (measured by numeric rating scale) and decrease in postoperative lung volumes were calculated with Spearman rank correlation test. Lung volumes decreased by 50% and were less than 40% of the predictive values postoperatively. Patients with BMI >25 had lower postoperative inspiratory capacity (IC) (33 ± 14% pred.) than normal-weight patients (39 ± 15% pred.), (P = 0.04). More pain during mobilisation was associated with higher decreases in postoperative lung volumes (VC: r = 0.33, P = 0.001; FEV(1): r = 0.35, P ≤ 0.0001; IC: r = 0.25, P = 0.01). Patients with high BMI are a risk group for decreased postoperative lung volumes and should therefore receive extra attention during postoperative care. As pain is related to a larger decrease in postoperative lung volumes, optimal pain relief for the patients should be identified.

  15. Gas exchange during exercise in different evolutional stages of chronic Chagas' heart disease.

    Science.gov (United States)

    Oliveira, F P; Pedrosa, R C; Giannella-Neto, A

    2000-12-01

    To compare gas exchange at rest and during exercise in patients with chronic Chagas' heart disease grouped according to the Los Andes clinical hemodynamic classification. We studied 15 healthy volunteers and 52 patients grouped according to the Los Andes clinical and hemodynamic classification as follows: 17 patients in group IA (normal electrocardiogram and echocardiogram), 9 patients in group IB (normal electrocardiogram and abnormal echocardiogram), 14 patients in group II (abnormal electrocardiogram and echocardiogram, without congestive heart failure), and 12 patients in group III (abnormal electrocardiogram and echocardiogram with congestive heart failure). The following variables were analyzed: oxygen consumption (V O2), carbon dioxide production (V CO2), gas exchange rate (R), inspiratory current volume (V IC), expiratory current volume (V EC), respiratory frequency, minute volume (V E), heart rate (HR), maximum load, O2 pulse, and ventilatory anaerobic threshold (AT). When compared with the healthy group, patients in groups II and III showed significant changes in the following variables: V O2 peak, V CO2 peak, V IC peak, V EC peak, E, HR, and maximum load. Group IA showed significantly better results for these same variables as compared with group III. The functional capacity of patients in the initial phase of chronic Chagas' heart disease is higher than that of patients in an advanced phase and shows a decrease that follows the loss in cardiac-hemodynamic performance.

  16. 30 CFR 57.22104 - Open flames (I-C mines).

    Science.gov (United States)

    2010-07-01

    ....22104 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Safety Standards for Methane in Metal and Nonmetal Mines Fire Prevention and Control § 57.22104 Open flames (I-C...

  17. The classical Starling resistor model often does not predict inspiratory airflow patterns in the human upper airway.

    Science.gov (United States)

    Owens, Robert L; Edwards, Bradley A; Sands, Scott A; Butler, James P; Eckert, Danny J; White, David P; Malhotra, Atul; Wellman, Andrew

    2014-04-15

    The upper airway is often modeled as a classical Starling resistor, featuring a constant inspiratory airflow, or plateau, over a range of downstream pressures. However, airflow tracings from clinical sleep studies often show an initial peak before the plateau. To conform to the Starling model, the initial peak must be of small magnitude or dismissed as a transient. We developed a method to simulate fast or slow inspirations through the human upper airway, to test the hypothesis that this initial peak is a transient. Eight subjects [4 obstructive sleep apnea (OSA), 4 controls] slept in an "iron lung" and wore a nasal mask connected to a continuous/bilevel positive airway pressure machine. Downstream pressure was measured using an epiglottic catheter. During non-rapid eye movement (NREM) sleep, subjects were hyperventilated to produce a central apnea, then extrathoracic pressure was decreased slowly (∼2-4 s) or abruptly (resistor model, the upper airway exhibits marked NED in some subjects.

  18. Paired maximum inspiratory and expiratory plain chest radiographs for assessment of airflow limitation in chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Takashi, E-mail: tkino@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Kawayama, Tomotaka, E-mail: kawayama_tomotaka@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Imamura, Youhei, E-mail: mamura_youhei@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Sakazaki, Yuki, E-mail: sakazaki@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Hirai, Ryo, E-mail: hirai_ryou@kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Ishii, Hidenobu, E-mail: shii_hidenobu@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Suetomo, Masashi, E-mail: jin_t_f_c@yahoo.co.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Matsunaga, Kazuko, E-mail: kmatsunaga@kouhoukai.or.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Azuma, Koichi, E-mail: azuma@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Fujimoto, Kiminori, E-mail: kimichan@med.kurume-u.ac.jp [Department of Radiology, Kurume University School of Medicine, Kurume (Japan); Hoshino, Tomoaki, E-mail: hoshino@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan)

    2015-04-15

    Highlights: •It is often to use computed tomography (CT) scan for diagnosis of chronic obstructive pulmonary disease. •CT scan is more expensive and higher. •A plane chest radiography more simple and cheap. Moreover, it is useful as detection of pulmonary emphysema, but not airflow limitation. •Our study demonstrated that the maximum inspiratory and expiratory plane chest radiography technique could detect severe airflow limitations. •We believe that the technique is helpful to diagnose the patients with chronic obstructive pulmonary disease. -- Abstract: Background: The usefulness of paired maximum inspiratory and expiratory (I/E) plain chest radiography (pCR) for diagnosis of chronic obstructive pulmonary disease (COPD) is still unclear. Objectives: We examined whether measurement of the I/E ratio using paired I/E pCR could be used for detection of airflow limitation in patients with COPD. Methods: Eighty patients with COPD (GOLD stage I = 23, stage II = 32, stage III = 15, stage IV = 10) and 34 control subjects were enrolled. The I/E ratios of frontal and lateral lung areas, and lung distance between the apex and base on pCR views were analyzed quantitatively. Pulmonary function parameters were measured at the same time. Results: The I/E ratios for the frontal lung area (1.25 ± 0.01), the lateral lung area (1.29 ± 0.01), and the lung distance (1.18 ± 0.01) were significantly (p < 0.05) reduced in COPD patients compared with controls (1.31 ± 0.02 and 1.38 ± 0.02, and 1.22 ± 0.01, respectively). The I/E ratios in frontal and lateral areas, and lung distance were significantly (p < 0.05) reduced in severe (GOLD stage III) and very severe (GOLD stage IV) COPD as compared to control subjects, although the I/E ratios did not differ significantly between severe and very severe COPD. Moreover, the I/E ratios were significantly correlated with pulmonary function parameters. Conclusions: Measurement of I/E ratios on paired I/E pCR is simple and

  19. Paired maximum inspiratory and expiratory plain chest radiographs for assessment of airflow limitation in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Kinoshita, Takashi; Kawayama, Tomotaka; Imamura, Youhei; Sakazaki, Yuki; Hirai, Ryo; Ishii, Hidenobu; Suetomo, Masashi; Matsunaga, Kazuko; Azuma, Koichi; Fujimoto, Kiminori; Hoshino, Tomoaki

    2015-01-01

    Highlights: •It is often to use computed tomography (CT) scan for diagnosis of chronic obstructive pulmonary disease. •CT scan is more expensive and higher. •A plane chest radiography more simple and cheap. Moreover, it is useful as detection of pulmonary emphysema, but not airflow limitation. •Our study demonstrated that the maximum inspiratory and expiratory plane chest radiography technique could detect severe airflow limitations. •We believe that the technique is helpful to diagnose the patients with chronic obstructive pulmonary disease. -- Abstract: Background: The usefulness of paired maximum inspiratory and expiratory (I/E) plain chest radiography (pCR) for diagnosis of chronic obstructive pulmonary disease (COPD) is still unclear. Objectives: We examined whether measurement of the I/E ratio using paired I/E pCR could be used for detection of airflow limitation in patients with COPD. Methods: Eighty patients with COPD (GOLD stage I = 23, stage II = 32, stage III = 15, stage IV = 10) and 34 control subjects were enrolled. The I/E ratios of frontal and lateral lung areas, and lung distance between the apex and base on pCR views were analyzed quantitatively. Pulmonary function parameters were measured at the same time. Results: The I/E ratios for the frontal lung area (1.25 ± 0.01), the lateral lung area (1.29 ± 0.01), and the lung distance (1.18 ± 0.01) were significantly (p < 0.05) reduced in COPD patients compared with controls (1.31 ± 0.02 and 1.38 ± 0.02, and 1.22 ± 0.01, respectively). The I/E ratios in frontal and lateral areas, and lung distance were significantly (p < 0.05) reduced in severe (GOLD stage III) and very severe (GOLD stage IV) COPD as compared to control subjects, although the I/E ratios did not differ significantly between severe and very severe COPD. Moreover, the I/E ratios were significantly correlated with pulmonary function parameters. Conclusions: Measurement of I/E ratios on paired I/E pCR is simple and

  20. Determination of Na+ and K+ ions in the high-level liquid waste by ion chromatography (IC)

    International Nuclear Information System (INIS)

    Chen Lianzhong; Ma Guilan

    1992-01-01

    The determination of Na + and k + ions in the high-level liquid waste is investigated using ion chromatography. In order to protect the low capacity ion exchange resin in single column IC and remove the transition metal as well as other heavy metal ions that are contained in liquid waste, the pretreatment column with EDTA chelating resin is used. Those impurity metal ions are strongly absorbed by EDTA chelating resin and 100% of Na + and K + ions in the solution are eluted. The ability of the decontamination of EDTA chelating resin is satisfactory. The sample of the high-level liquid waste is diluted appropriately, then an aliquot of the sample is passed through the pretreatment column with EDTA chelating resin, the eluate is analysed by single column ion chromatography. The precision of this method is better than 5% for the determination of Na + and K + ions (at μg· ml -1 level)

  1. An NFC-Enabled CMOS IC for a Wireless Fully Implantable Glucose Sensor.

    Science.gov (United States)

    DeHennis, Andrew; Getzlaff, Stefan; Grice, David; Mailand, Marko

    2016-01-01

    This paper presents an integrated circuit (IC) that merges integrated optical and temperature transducers, optical interface circuitry, and a near-field communication (NFC)-enabled digital, wireless readout for a fully passive implantable sensor platform to measure glucose in people with diabetes. A flip-chip mounted LED and monolithically integrated photodiodes serve as the transduction front-end to enable fluorescence readout. A wide-range programmable transimpedance amplifier adapts the sensor signals to the input of an 11-bit analog-to-digital converter digitizing the measurements. Measurement readout is enabled by means of wireless backscatter modulation to a remote NFC reader. The system is able to resolve current levels of less than 10 pA with a single fluorescent measurement energy consumption of less than 1 μJ. The wireless IC is fabricated in a 0.6-μm-CMOS process and utilizes a 13.56-MHz-based ISO15693 for passive wireless readout through a NFC interface. The IC is utilized as the core interface to a fluorescent, glucose transducer to enable a fully implantable sensor-based continuous glucose monitoring system.

  2. Fermi Non-detections of Four X-Ray Jet Sources and Implications for the IC/CMB Mechanism

    Science.gov (United States)

    Breiding, Peter; Meyer, Eileen T.; Georganopoulos, Markos; Keenan, M. E.; DeNigris, N. S.; Hewitt, Jennifer

    2017-11-01

    Since its launch in 1999, the Chandra X-ray observatory has discovered several dozen X-ray jets associated with powerful quasars. In many cases, the X-ray spectrum is hard and appears to come from a second spectral component. The most popular explanation for the kpc-scale X-ray emission in these cases has been inverse-Compton (IC) scattering of Cosmic Microwave Background (CMB) photons by relativistic electrons in the jet (the IC/CMB model). Requiring the IC/CMB emission to reproduce the observed X-ray flux density inevitably predicts a high level of gamma-ray emission, which should be detectable with the Fermi Large Area Telescope (LAT). In previous work, we found that gamma-ray upper limits from the large-scale jets of 3C 273 and PKS 0637-752 violate the predictions of the IC/CMB model. Here, we present Fermi/LAT flux density upper limits for the X-ray jets of four additional sources: PKS 1136-135, PKS 1229-021, PKS 1354+195, and PKS 2209+080. We show that these limits violate the IC/CMB predictions at a very high significance level. We also present new Hubble Space Telescope observations of the quasar PKS 2209+080 showing a newly detected optical jet, and Atacama Large Millimeter/submillimeter Array band 3 and 6 observations of all four sources, which provide key constraints on the spectral shape that enable us to rule out the IC/CMB model.

  3. The next generation in optical transport semiconductors: IC solutions at the system level

    Science.gov (United States)

    Gomatam, Badri N.

    2005-02-01

    In this tutorial overview, we survey some of the challenging problems facing Optical Transport and their solutions using new semiconductor-based technologies. Advances in 0.13um CMOS, SiGe/HBT and InP/HBT IC process technologies and mixed-signal design strategies are the fundamental breakthroughs that have made these solutions possible. In combination with innovative packaging and transponder/transceiver architectures IC approaches have clearly demonstrated enhanced optical link budgets with simultaneously lower (perhaps the lowest to date) cost and manufacturability tradeoffs. This paper will describe: *Electronic Dispersion Compensation broadly viewed as the overcoming of dispersion based limits to OC-192 links and extending link budgets, *Error Control/Coding also known as Forward Error Correction (FEC), *Adaptive Receivers for signal quality monitoring for real-time estimation of Q/OSNR, eye-pattern, signal BER and related temporal statistics (such as jitter). We will discuss the theoretical underpinnings of these receiver and transmitter architectures, provide examples of system performance and conclude with general market trends. These Physical layer IC solutions represent a fundamental new toolbox of options for equipment designers in addressing systems level problems. With unmatched cost and yield/performance tradeoffs, it is expected that IC approaches will provide significant flexibility in turn, for carriers and service providers who must ultimately manage the network and assure acceptable quality of service under stringent cost constraints.

  4. A nu-space for ICS: characterization and application to measure protein transport in live cells.

    Science.gov (United States)

    Potvin-Trottier, Laurent; Chen, Lingfeng; Horwitz, Alan Rick; Wiseman, Paul W

    2013-08-01

    We introduce a new generalized theoretical framework for image correlation spectroscopy (ICS). Using this framework, we extend the ICS method in time-frequency ( ν , nu) space to map molecular flow of fluorescently tagged proteins in individual living cells. Even in the presence of a dominant immobile population of fluorescent molecules, nu-space ICS (nICS) provides an unbiased velocity measurement, as well as the diffusion coefficient of the flow, without requiring filtering. We also develop and characterize a tunable frequency-filter for STICS that allows quantification of the density, the diffusion coefficient and the velocity of biased diffusion. We show that the techniques are accurate over a wide range of parameter space in computer simulation. We then characterize the retrograde flow of adhesion proteins ( α 6- and αLβ 2-GFP integrins and mCherry-paxillin) in CHO.B2 cells plated on laminin and ICAM ligands respectively. STICS with a tunable frequency filter, in conjunction with nICS, measures two new transport parameters, the density and transport bias coefficient (a measure of the diffusive character of a flow/biased diffusion), showing that molecular flow in this cell system has a significant diffusive component. Our results suggest that the integrinligand interaction, along with the internal myosin-motor generated force, varies for different integrin-ligand pairs, consistent with previous results.

  5. A CENSUS OF YOUNG STARS AND BROWN DWARFS IN IC 348 AND NGC 1333

    Energy Technology Data Exchange (ETDEWEB)

    Luhman, K. L.; Esplin, T. L. [Department of Astronomy and Astrophysics, The Pennsylvania State University, University Park, PA 16802 (United States); Loutrel, N. P., E-mail: kluhman@astro.psu.edu [Department of Physics, Montana State University, Bozeman, MT 59715 (United States)

    2016-08-10

    We have obtained optical and near-infrared spectra of candidate members of the star-forming clusters IC 348 and NGC 1333. We classify 100 and 42 candidates as new members of the clusters, respectively, which brings the total numbers of known members to 478 and 203. We also have performed spectroscopy on a large majority of the previously known members of NGC 1333 in order to provide spectral classifications that are measured with the same scheme that has been applied to IC 348 in previous studies. The new census of members is nearly complete for K {sub s}< 16.8 at A {sub J}< 1.5 in IC 348 and for K {sub s}< 16.2 at A {sub J}< 3 in NGC 1333, which correspond to masses of ≳0.01 M {sub ⊙} for ages of 3 Myr according to theoretical evolutionary models. The faintest known members extend below these completeness limits and appear to have masses of ∼0.005 M {sub ⊙}. In extinction-limited samples of cluster members, NGC 1333 exhibits a higher abundance of objects at lower masses than IC 348. It would be surprising if the initial mass functions of these clusters differ significantly given their similar stellar densities and formation environments. Instead, it is possible that average extinctions are lower for less massive members of star-forming clusters, in which case extinction-limited samples could be biased in favor of low-mass objects in the more heavily embedded clusters like NGC 1333. In the Hertzsprung–Russell diagram, the median sequences of IC 348 and NGC 1333 coincide with each other for the adopted distances of 300 and 235 pc, which would suggest that they have similar ages. However, NGC 1333 is widely believed to be younger than IC 348 based on its higher abundance of disks and protostars and its greater obscuration. Errors in the adopted distances may be responsible for this discrepancy.

  6. A Search for Hydrodynamical Interaction Between the ISM and Radio Jets in IC4296

    Science.gov (United States)

    Mackie, Glen

    1998-01-01

    The ROSAT HRI Data set on IC 4296 has been reduced and analysed. A draft paper on the small-scale structure of x-ray emission and its relation to the radio emission has been written. Mackie left the Smithsonian Astrophysical Observatory in September 1997 and in January 1998 he joined the staff at Carter Observatory, New Zealand. Mackie is currently (May 1998) upgrading computer software at Carter to run IRAF-PROS and XSPEC x-ray software packages in order to reduce and analyze archival ROSAT PSPC data on IC 4296. The PSPC results are needed to investigate the hot gas temperature and abundance properties that will be used in conjunction with the radio jet properties to determine the hydrodynamical interaction status of IC 4296, and finalize the results of a research paper.

  7. Performance of Naturally Aspirating IC Engines Operating at High ...

    African Journals Online (AJOL)

    The loss of power and the increase of fuel consumption of naturally aspirating IC engines operating with low atmospheric pressure at high altitude as well as changes in the mixture quality with non adapting mixture formation systems are principally known. Other effects like the additional advance of ignition timing in petrol ...

  8. Tailored Barium Swallow Study

    Science.gov (United States)

    ... Impulse Oscillimetry (IOS) Hypoxic and Hypercapnic Drive Response Lung Diffusion Capacity Testing (DLCO) Maximum Inspiratory/Expiratory Pressures Nitrogen Washout Performing Pressure Volume Study Performing Routine Pulmonary Test Performing Spirometry Test ...

  9. Esophagram (Barium Swallow Study)

    Science.gov (United States)

    ... Impulse Oscillimetry (IOS) Hypoxic and Hypercapnic Drive Response Lung Diffusion Capacity Testing (DLCO) Maximum Inspiratory/Expiratory Pressures Nitrogen Washout Performing Pressure Volume Study Performing Routine Pulmonary Test Performing Spirometry Test ...

  10. High energy ion implantation for IC processing

    International Nuclear Information System (INIS)

    Oosterhoff, S.

    1986-01-01

    In this thesis the results of fundamental research on high energy ion implantation in silicon are presented and discussed. The implantations have been carried out with the 500 kV HVEE ion implantation machine, that was acquired in 1981 by the IC technology and Electronics group at Twente University of Technology. The damage and anneal behaviour of 1 MeV boron implantations to a dose of 10 13 /cm 2 have been investigated as a function of anneal temperature by sheet resistance, Hall and noise measurements. (Auth.)

  11. HPLC Analysis of Phenolics Compounds and Antioxidant Capacity of Leaves of Vitex megapotamica (Sprengel Moldenke

    Directory of Open Access Journals (Sweden)

    Félix Alexandre Antunes Soares

    2013-07-01

    Full Text Available Vitex megapotamica (Sprengel Moldenke belongs to the Verbenaceae family and is popularly known as “tarumã”. The antioxidant capacity of fractions and crude extract from the leaves of V. megapotamica were determined in this study through the capacity to remove reactive species and phenolic compounds were quantified in the various fractions. The IC50 (DPPH ranged from 14.17 ± 0.76 to 37.63 ± 0.98 µg/mL. The ethyl acetate fraction might contain the strongest lipid peroxidation inhibitory compounds with an IC50 of 16.36 ± 5.09 µg/mL, being also the one with the highest content of polyphenols (522.4 ± 1.12 mg/g, flavonoids (220.48 ± 0.30 mg/g and condensed tannins (3.86 ± 0.53 mg/g. Compounds quantified by HPLC/DAD in the crude extract and fractions were chlorogenic and rosmarinic acids. Higher dosages of the extracts were more effective in reducing levels of plasma protein carbonyls and were also shown to be able to remove reactive species by a 2',7'-dichlorofluorescein diacetate assay, reducing oxidative stress in all tested fractions. Results obtained indicated that V. megapotamica exhibits good potential to prevent diseases caused by the overproduction of free radicals and it might also be used as a potential source of natural antioxidant agents.

  12. Experimental and theoretical analysis of integrated circuit (IC) chips on flexible substrates subjected to bending

    Science.gov (United States)

    Chen, Ying; Yuan, Jianghong; Zhang, Yingchao; Huang, Yonggang; Feng, Xue

    2017-10-01

    The interfacial failure of integrated circuit (IC) chips integrated on flexible substrates under bending deformation has been studied theoretically and experimentally. A compressive buckling test is used to impose the bending deformation onto the interface between the IC chip and the flexible substrate quantitatively, after which the failed interface is investigated using scanning electron microscopy. A theoretical model is established based on the beam theory and a bi-layer interface model, from which an analytical expression of the critical curvature in relation to the interfacial failure is obtained. The relationships between the critical curvature, the material, and the geometric parameters of the device are discussed in detail, providing guidance for future optimization flexible circuits based on IC chips.

  13. On the truth of Ksub(IC) values, taken from RD 50-260-81 methodical instructions

    International Nuclear Information System (INIS)

    Ivanova, V.S.

    1984-01-01

    Ways to evaluate correctness of Ksub(Ic) values, taking into account self-similarity of prefracture zone and stability of critical density of strain energy, as well as necessity to introduce corrections for plastic strain zone, are considered. Correctness of Ksub(Ic) values and temperature range of tough (hole) fracture mechanism realization, taking into account the effect of plastic strain compression degree for the Ksub(Ic) vaclue established in the basic experiment; necessity to introduce on the basis of similarity theory approaches the method of plastic strain compression degree during the development of state standard project, so as to decrease data spread and to increase information value of separate experiments, when studying crack resistance of plastic materials, have been confirmed

  14. Migration to Current Open Source Technologies by MagIC Enables a More Responsive Website, Quicker Development Times, and Increased Community Engagement

    Science.gov (United States)

    Jarboe, N.; Minnett, R.; Koppers, A.; Constable, C.; Tauxe, L.; Jonestrask, L.

    2017-12-01

    The Magnetics Information Consortium (MagIC) supports an online database for the paleo, geo, and rock magnetic communities ( https://earthref.org/MagIC ). Researchers can upload data into the archive and download data as selected with a sophisticated search system. MagIC has completed the transition from an Oracle backed, Perl based, server oriented website to an ElasticSearch backed, Meteor based thick client website technology stack. Using JavaScript on both the sever and the client enables increased code reuse and allows easy offloading many computational operations to the client for faster response. On-the-fly data validation, column header suggestion, and spreadsheet online editing are some new features available with the new system. The 3.0 data model, method codes, and vocabulary lists can be browsed via the MagIC website and more easily updated. Source code for MagIC is publicly available on GitHub ( https://github.com/earthref/MagIC ). The MagIC file format is natively compatible with the PmagPy ( https://github.com/PmagPy/PmagPy) paleomagnetic analysis software. MagIC files can now be downloaded from the database and viewed and interpreted in the PmagPy GUI based tool, pmag_gui. Changes or interpretations of the data can then be saved by pmag_gui in the MagIC 3.0 data format and easily uploaded to the MagIC database. The rate of new contributions to the database has been increasing with many labs contributing measurement level data for the first time in the last year. Over a dozen file format conversion scripts are available for translating non-MagIC measurement data files into the MagIC format for easy uploading. We will continue to work with more labs until the whole community has a manageable workflow for contributing their measurement level data. MagIC will continue to provide a global repository for archiving and retrieving paleomagnetic and rock magnetic data and, with the new system in place, be able to more quickly respond to the community

  15. The unusual kinematics of the galaxy IC 10

    International Nuclear Information System (INIS)

    Cohen, R.J.

    1979-01-01

    Observations of neutral hydrogen emission from the galaxy IC 10 show a large outer envelope of gas more than 1 0 in extent. The emission has a velocity gradient along the major axis in the opposite sense to that of the central concentration mapped by Shostak. This unusual velocity reversal can be interpreted in terms of a warped gas-layer in normal rotation and seen face-on. (author)

  16. In vitro capacity and in vivo antioxidant potency of sedimental extract of Tinospora cordifolia in streptozotocin induced type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Ramachandran Kannadhasan

    2012-12-01

    Results: Chemical analysis with SETc in vitro for its IC50 proves a key evident for its total antioxidant capacity of around 2046 times, in 1000 mg/kg of fixed dose per oral for in vivo analysis. In contrast to the above, the lipid peroxide levels and in vivo enzymic and non-enzymic antioxidant levels were found to possess most significant difference (p

  17. The measurement of Ksub(IC) in single crystal SiC using the indentation method

    International Nuclear Information System (INIS)

    Henshall, J.L.; Brookes, C.A.

    1985-01-01

    The present work has concentrated on investigating the underlying fracture toughness behaviour of SiC single crystals. This material was chosen because of the commercial importance of the various polycrystalline forms of SiC and the relative ready availability of reasonably sized single crystals. This study has examined the feasibility of using the indentation technique to determine Ksub(IC) in SiC single crystals. This requires much more less complex experimentation and also affords the possibility of being able to use this method to study the orientation dependence of Ksub(IC) in a similar manner to that used to investigate anisotropy in indentation hardness behaviour. A single crystal of 6H-SiC was used for all the hardness and conventional Ksub(IC) results reported here. The particular polytype and orientation were determined using the Laue X-ray method. All the measurements were made under ambient conditions. Three-point bend tests, with a 6 mm span on single edge notched beams, SENB, orientated such that the plane of the notch was brace 112-bar0 brace and the crack propagation direction were used for the conventional Ksub(IC) tests. The hardness indentations were all made on one particular SENB test piece after it had been fractured. The results are discussed. (author)

  18. Complex Heat Capacity of Lithium Borate Glasses Studied by Modulated DSC

    International Nuclear Information System (INIS)

    Matsuda, Yu; Ike, Yuji; Matsui, Chihiro; Kodama, Masao; Kojima, Seiji

    2006-01-01

    Complex heat capacity, C p * = C p ' - iC p '', of lithium borate glasses Li2O·(1-x)B2O3 (x = 0.00 - 0.33) has been investigated by Modulated DSC (MDSC). We have successfully observed the frequency dependent C p * by MDSC in the frequency range 0.01 to 0.1 Hz, and the average relaxation time of glass transition has been determined as a function of temperature. Moreover, the composition dependence of the thermal properties has been investigated. The calorimetric glass transition temperatures become higher with the increase of concentration of Li2O and show the board maximum around x = 0.26-0.28. The width of glass transition region becomes narrower as Li2O increases. These results relate to the change of the fragility of the system. It has been proven that the complex heat capacity spectroscopy by MDSC is a powerful tool to investigate the glass transition phenomena

  19. Enhanced urothelial expression of human chorionic gonadotropin beta (hCGβ) in bladder pain syndrome/interstitial cystitis (BPS/IC).

    Science.gov (United States)

    Schwalenberg, Thilo; Stolzenburg, Jens-Uwe; Ho, Thi Phuc; Mallock, Tobias; Hartenstein, Siegurd; Alexander, Henry; Zimmermann, Gerolf; Hohenfellner, Rudolf; Denzinger, Stefan; Burger, Maximilian; Horn, Lars-Christian; Neuhaus, Jochen

    2012-06-01

    Bladder pain syndrome/interstitial cystitis (BPS/IC) is associated with urothelial lesions. Pathomechanisms of urothelial damage and factors for urothelial restoration are unknown. hCG is a factor for cellular differentiation, angiogenesis and immune competence of the endometrium during pregnancy. Clinical observations demonstrate improvement of BPS/IC symptoms during pregnancy or during infertility treatment with hCG. Our research aims were to examine the expression of hCG and luteinizing hormone receptor (LHR) in the urothelium of BPS/IC patients and compare the levels of hCGβ with healthy controls. Bladder biopsies of BPS/IC (CLSM: n = 10; qPCR: n = 15); Tumour-free control tissue from cystectomies (n = 12). hCGα, hCGβ and LHR expression were examined by confocal laser scanning microscopy (CLSM), and hCGβ expression was quantified. hCGβ5 and hCGβ7 mRNA splice variants were quantified in real-time polymerase chain reaction. We found constitutive expression of hCGα, hCGβ and LHR in healthy controls. HCGβ was significantly upregulated in BPS/IC patients in CLSM. PCR analysis revealed higher levels of hCGβ7 than hCGβ5 in controls and BPS/IC patients. The constitutive expression of hCG and LHR speaks in favour for a functional signalling in urothelial cells without any association with either pregnancy or tumour. We show for the first time that hCGβ is upregulated in BPS/IC urothelium and that hCGβ7 is the dominant splice variant in those cells. Our findings imply a major role of hCG for urothelial integrity and a disturbance of hCG signalling in case of BPS/IC. We conclude that hCG could gain therapeutical relevance in the future.

  20. Respiratory muscle stretch gymnastics in patients with post coronary artery bypass grafting pain: impact on respiratory muscle function, activity, mood and exercise capacity.

    Science.gov (United States)

    Aida, Nobuko; Shibuya, Masako; Yoshino, Katsuki; Komoda, Masaji; Inoue, Tomoko

    2002-12-01

    A new rehabilitation (New-RH) program including respiratory muscle stretch gymnastics (RMSG) was developed to alleviate post-coronary artery bypass grafting pain (PCP). Effects on respiratory muscle function, pain, activities of daily living (ADL), mood and exercise capacity were investigated. Subjects were 16 consecutive patients undergoing median full sternotomy coronary artery bypass grafting (CABG), and were randomly divided into equal New-RH (S-group) and conventional therapy (C-group) groups. Rib cage dominant breathing was observed postoperatively in both groups. With preoperative tan deltaVrc/deltaVab, increases at 1-week postoperatively and decreases at discharge for S-group tended to exceed those of C-group (p > .05). Decreased maximum inspiratory and expiratory pressure status for functional residual capacity and percent forced expiratory volume in one second at discharge again only tended to be smaller for S-group (p > .05). S-group displayed significantly reduced pain around both scapulas at discharge (p = .049), and increased mean overall ADL and profile of mood states (POMS)/Vigor scores (p = .031 and p = .018, respectively). POMS/Tension-Anxiety scores at discharge for S-group were significantly smaller than those preoperatively (p = .025), and S-group displayed significantly increased distance walked over 6-minutes at discharge than C-group (p = .029). New-RH improves patient participation in exercise therapy and increases exercise capacity by reducing PCP, relieving anxiety and tension, and improving ADL.

  1. Recent Progress in Planetary Laboratory Astrophysics achieved with NASA Ames' COSmIC Facility

    Science.gov (United States)

    Salama, Farid; Sciamma-O'Brien, Ella; Bejaoui, Salma

    2016-10-01

    We describe the characteristics and the capabilities of the laboratory facility, COSmIC, that was developed at NASA Ames to generate, process and analyze interstellar, circumstellar and planetary analogs in the laboratory [1]. COSmIC stands for "Cosmic Simulation Chamber" and is dedicated to the study of neutral and ionized molecules and nanoparticles under the low temperature and high vacuum conditions that are required to simulate various space environments such as planetary atmospheres. COSmIC integrates a variety of state-of-the-art instruments that allow forming, processing and monitoring simulated space conditions for planetary, circumstellar and interstellar materials in the laboratory. The COSmIC experimental setup is composed of a Pulsed Discharge Nozzle (PDN) expansion, that generates a plasma in the stream of a free supersonic jet expansion, coupled to two high-sensitivity, complementary in situ diagnostics: a Cavity Ring Down Spectroscopy (CRDS) and laser induced fluorescence (LIF) systems for photonic detection [2, 3], and a Reflectron Time-Of-Flight Mass Spectrometer (ReTOF-MS) for mass detection [4].Recent results obtained using COSmIC will be highlighted. In particular, the progress that has been achieved in an on-going study investigating the formation and the characterization of laboratory analogs of Titan's aerosols generated from gas-phase molecular precursors [5] will be presented. Plans for future laboratory experiments on planetary molecules and aerosols in the growing field of planetary laboratory astrophysics will also be addressed, as well as the implications of studies underway for astronomical observations.References: [1] Salama F., in Organic Matter in Space, IAU S251, Kwok & Sandford eds, CUP, S251, 4, 357 (2008).[2] Biennier L., Salama, F., Allamandola L., & Scherer J., J. Chem. Phys., 118, 7863 (2003)[3] Tan X, & Salama F., J. Chem. Phys. 122, 84318 (2005)[4] Ricketts C., Contreras C., Walker, R., Salama F., Int. J. Mass Spec, 300

  2. Selective expression of myosin IC Isoform A in mouse and human cell lines and mouse prostate cancer tissues.

    Directory of Open Access Journals (Sweden)

    Ivanna Ihnatovych

    Full Text Available Myosin IC is a single headed member of the myosin superfamily. We recently identified a novel isoform and showed that the MYOIC gene in mammalian cells encodes three isoforms (isoforms A, B, and C. Furthermore, we demonstrated that myosin IC isoform A but not isoform B exhibits a tissue specific expression pattern. In this study, we extended our analysis of myosin IC isoform expression patterns by analyzing the protein and mRNA expression in various mammalian cell lines and in various prostate specimens and tumor tissues from the transgenic mouse prostate (TRAMP model by immunoblotting, qRT-PCR, and by indirect immunohistochemical staining of paraffin embedded prostate specimen. Analysis of a panel of mammalian cell lines showed an increased mRNA and protein expression of specifically myosin IC isoform A in a panel of human and mouse prostate cancer cell lines but not in non-cancer prostate or other (non-prostate- cancer cell lines. Furthermore, we demonstrate that myosin IC isoform A expression is significantly increased in TRAMP mouse prostate samples with prostatic intraepithelial neoplasia (PIN lesions and in distant site metastases in lung and liver when compared to matched normal tissues. Our observations demonstrate specific changes in the expression of myosin IC isoform A that are concurrent with the occurrence of prostate cancer in the TRAMP mouse prostate cancer model that closely mimics clinical prostate cancer. These data suggest that elevated levels of myosin IC isoform A may be a potential marker for the detection of prostate cancer.

  3. In-situ volumetric topography of IC chips for defect detection using infrared confocal measurement with active structured light

    International Nuclear Information System (INIS)

    Chen, Liang-Chia; Le, Manh-Trung; Phuc, Dao Cong; Lin, Shyh-Tsong

    2014-01-01

    The article presents the development of in-situ integrated circuit (IC) chip defect detection techniques for automated clipping detection by proposing infrared imaging and full-field volumetric topography. IC chip inspection, especially held during or post IC packaging, has become an extremely critical procedure in IC fabrication to assure manufacturing quality and reduce production costs. To address this, in the article, microscopic infrared imaging using an electromagnetic light spectrum that ranges from 0.9 to 1.7 µm is developed to perform volumetric inspection of IC chips, in order to identify important defects such as silicon clipping, cracking or peeling. The main difficulty of infrared (IR) volumetric imaging lies in its poor image contrast, which makes it incapable of achieving reliable inspection, as infrared imaging is sensitive to temperature difference but insensitive to geometric variance of materials, resulting in difficulty detecting and quantifying defects precisely. To overcome this, 3D volumetric topography based on 3D infrared confocal measurement with active structured light, as well as light refractive matching principles, is developed to detect defects the size, shape and position of defects in ICs. The experimental results show that the algorithm is effective and suitable for in-situ defect detection of IC semiconductor packaging. The quality of defect detection, such as measurement repeatability and accuracy, is addressed. Confirmed by the experimental results, the depth measurement resolution can reach up to 0.3 µm, and the depth measurement uncertainty with one standard deviation was verified to be less than 1.0% of the full-scale depth-measuring range. (paper)

  4. OSL signal of IC chips from mobile phones for dose assessment in accidental dosimetry

    International Nuclear Information System (INIS)

    Mrozik, A.; Marczewska, B.; Bilski, P.; Książek, M.

    2017-01-01

    The rapid assessment of the radiation dose is very important for the prediction of biological effects after unintended exposition. The materials for use as dosimeters in accidental dosimetry should be everyday objects which are usually placed near the human body, for example mobile phones. IC (Integrated Circuit) chip is one of several electronic components of mobile phones which give a luminescent signal. The measurements of samples from different mobile phones and smartphones were conducted by optically stimulated luminescence (OSL) and thermoluminescence (TL) methods. The OSL measurement was performed in two ways: with readouts at room temperature and at 100 °C. This work is focused on determination of OSL dose response of IC chips, minimum detectable dose (MDD), OSL signal stability in the time after the exposition, its repeatability and sensitivity to light. Several tests of the assessment of unknown doses were also conducted. The readouts at 100 °C indicate the reducing of the fading of OSL signal in the first hours after irradiation in comparison with room temperature readouts. The obtained results showed relatively good dosimetric properties of IC chips: their high sensitivity to the ionizing radiation, linear dose response up to 10 Gy and a good reproducibility of OSL signal which can allow the dose recovery of doses less than 2 Gy in 14 days after an incident with the accuracy better than 25%. The fading is a drawback of IC chips and the fading factor should be considered when calculating the dose. - Highlights: • IC chips from smartphones demonstrated high potential for accidental dosimetry. • Minimum detectable dose was estimated as a value of 50 mGy. • Samples showed linear dose response for the dose range from 0.05 Gy up to 10 Gy.

  5. Clinical efficacy and safety of ICS/LABA in patients with combined idiopathic pulmonary fibrosis and emphysema.

    Science.gov (United States)

    Dong, Fushi; Zhang, Yimei; Chi, Fangzhou; Song, Qi; Zhang, Lijuan; Wang, Yupeng; Che, Chunli

    2015-01-01

    The study aim was to explore the clinical efficacy and safety of inhaled corticosteroids (ICS)/long-acting beta2-agonists (LABA) in combined with idiopathic pulmonary fibrosis and emphysema. 45 patients with combined idiopathic pulmonary fibrosis and emphysema (CPFE) who were treated with ICS/LABA (Group A), 24 patients with CPFE who were treated without ICS/LABA (Group B) and 35 patients with idiopathic pulmonary fibrosis (IPF) (Group C) were enrolled into this study. Then, clinical efficacy and safety of ICS/LABA was analyzed through lung function scores and lung high-resolution computed tomography (HRCT) scans. Compared with baseline levels, the FEV1%, FVC% and DLCO% levels were increased 11.2%, 13.53% and 12.8% respectively in group A, but declined 14.21%, 16.8% and 21.25% respectively in group B, meanwhile, lung HRCT score was declined 9.31 in group A but increased 14.87 in group B, and there was significant difference between group A and group B (P0.05). The incidence of adverse reaction was higher in group A than that in group B during this study, but there was no significant difference (P>0.05). ICS/LABA therapy could improve lung function condition in patients with CPFE and declined acute out-break frequency and severity of diseases during acute episode period.

  6. Computer modeling of magnetic structure for IC-35 cyclotron

    International Nuclear Information System (INIS)

    Alenitskij, Yu.G.; Morozov, N.A.

    1998-01-01

    An extensive series of calculations has been carried out in order to design the magnetic structure of the IC-35 cyclotron for radioisotope production. The calculations were carried out by 2-D POISCR code. The average magnetic field and its variation were produced with the help of two different calculation models. The parameters of the cyclotron magnetic system are presented

  7. Effects of inspiratory resistance, inhaled beta-agonists and histamine on canine tracheal blood flow

    International Nuclear Information System (INIS)

    Kelly, W.T.; Baile, E.M.; Brancatisano, A.; Pare, P.D.; Engel, L.A.

    1992-01-01

    Tracheobronchial blood flow is potentially important in asthma as it could either influence the clearance of mediators form the airways, thus affecting the duration and severity of bronchoispasm, or enhance oedema formation with a resultant increase in airflow obstruction. In anaesthetized dogs, spontaneously breathing via a tracheostomy, we investigated the effects of three interventions which are relevant to acute asthma attacks and could potentially influence blood flow and its distribution to the mucosa and remaining tissues of the trachea: 1) increased negative intrathoracic pressure swings (-25±1 cmH 2 O) induced by an inspiratory resistance; 2) variable inhaled doses of a beta-adrenoceptor-agonist (terbutaline); and 3) aerosolized histamine sufficient to produce a threefold increase in pulmonary resistance. Microspheres labelled with different radioisotopes were used to measure blood flow. Resistive breathing did not influence tracheobronchial blood flow. Following a large dose of terbutaline, mucosal blood flow (Qmb) increased by 50%. After inhaled histamine, Qmb reached 265% of the baseline value. We conclude that, whereas increased negative pressure swings do not influence tracheobronchial blood flow or its distribution, inhalation of aerosolized terbutaline, corresponding to a conventionally nebulized dose, increases mucosal blood flow. Our results also confirm that inhaled histamine, in a dose sufficient to produce moderate bronchoconstriction, increases tracheal mucosal blood flow in the area of deposition. (au)

  8. Effects of inspiratory resistance, inhaled beta-agonists and histamine on canine tracheal blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, W.T.; Baile, E.M.; Brancatisano, A.; Pare, P.D.; Engel, L.A. (Dept. of Respiratory Medicine, Westmead Hospital, Westmead, NSW (Australia))

    1992-01-01

    Tracheobronchial blood flow is potentially important in asthma as it could either influence the clearance of mediators form the airways, thus affecting the duration and severity of bronchoispasm, or enhance oedema formation with a resultant increase in airflow obstruction. In anaesthetized dogs, spontaneously breathing via a tracheostomy, we investigated the effects of three interventions which are relevant to acute asthma attacks and could potentially influence blood flow and its distribution to the mucosa and remaining tissues of the trachea: (1) increased negative intrathoracic pressure swings (-25[+-]1 cmH[sub 2]O) induced by an inspiratory resistance; (2) variable inhaled doses of a beta-adrenoceptor-agonist (terbutaline); and (3) aerosolized histamine sufficient to produce a threefold increase in pulmonary resistance. Microspheres labelled with different radioisotopes were used to measure blood flow. Resistive breathing did not influence tracheobronchial blood flow. Following a large dose of terbutaline, mucosal blood flow (Qmb) increased by 50%. After inhaled histamine, Qmb reached 265% of the baseline value. We conclude that, whereas increased negative pressure swings do not influence tracheobronchial blood flow or its distribution, inhalation of aerosolized terbutaline, corresponding to a conventionally nebulized dose, increases mucosal blood flow. Our results also confirm that inhaled histamine, in a dose sufficient to produce moderate bronchoconstriction, increases tracheal mucosal blood flow in the area of deposition. (au).

  9. Droplet-Wall/Film Impact in IC Engine Applications

    Science.gov (United States)

    2017-08-14

    Report: Droplet-Wall/ Film Impact in IC Engine Applications (ARO Topic 1.4.1 under ARO’s Dr. Ralph A. Anthenien) The views, opinions and/or findings...Participants: RPPR Final Report as of 12-Oct-2017 Agreement Number: W911NF-16-1-0449 Organization: Princeton University Title: Droplet-Wall/ Film Impact...droplets impacting a wet surface under various film thickness, which plays a critical role in controlling the efficiency of applications such as those

  10. Safety systems I/C equipment reliability analyses of the Kozloduy NPP units 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Halev, G; Christov, N [Risk Engineering Ltd., Sofia (Bulgaria)

    1996-12-31

    The purpose of the analysis is to assess the safety systems I/C equipment reliability. The assessment includes: quantification of the safety systems unavailability due to component failures; definition of the minimal cut sets leading to the analysed safety systems failure; quantification of the I/C equipment importance measures of the dominant contribution components. The safety systems I/C equipment reliability has been analysed using PSAPACK (a code for probabilistic safety assessment). Fault trees for the following safety systems of the Kozloduy-3 and Kozloduy-4 reactors have been constructed: neutron flow control equipment, reactor protection system, main coolant pumps, pressurizer safety valves `Sempell`, steam dump systems, spray system, low pressure injection system, emergency feeding water system, essential service water system. THree separate reports have been issued containing the performed analyses and results. 1 ref.

  11. Antioxidant activity of the giant jellyfish Nemopilema nomurai measured by the oxygen radical absorbance capacity and hydroxyl radical averting capacity methods.

    Science.gov (United States)

    Harada, Kazuki; Maeda, Toshimichi; Hasegawa, Yoshiro; Tokunaga, Takushi; Ogawa, Shinya; Fukuda, Kyoko; Nagatsuka, Norie; Nagao, Keiko; Ueno, Shunshiro

    2011-01-01

    The giant jellyfish Nemopilema nomurai (reaching sizes of up to 2 m diameter and 150 kg), which forms dense blooms, has caused extensive damage to fisheries by overloading trawl nets, while its toxic nematocysts cause dermatological symptoms. Giant jellyfish are currently discarded on the grounds of pest control. However, the giant jellyfish is considered to be edible and is part of Chinese cuisine. Therefore, we investigated whether any benefits for human health may be derived from consumption of the jellyfish in order to formulate medicated diets. Antioxidant activity of Nemopilema nomurai was measured using the oxygen radical absorbance capacity (ORAC) and hydroxyl radical averting capacity (HORAC) methods. Based on the results, the ORAC value of the giant jellyfish freeze-dried sample was 541 µmol trolox equivalent (TE)/100 g and the HORAC value was 3,687 µmol gallic acid equivalent (GAE)/100 g. On the other hand, the IC50 value of hydroxyl radical scavenging activity measured by using the electron spin resonance method was 3.3%. In conclusion, the results suggest that the freeze-dried powder of the giant jellyfish Nemopilema nomurai is a potentially beneficial food for humans.

  12. CT quantification of lung and airways in normal Korean subjects

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Song Soo; Lee, Jeong Eun; Shin, Hye Soo [Dept. of Radiology, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon (Korea, Republic of); Jin, Gong Yong; Li, Yuan Zhe [Dept. of Radiology, Research Institute of Clinical Medicine of Chonbuk National University-Biomedical Research Institute of Chonbuk National University Hospital, Jeonju (Korea, Republic of)

    2017-08-01

    To measure and compare the quantitative parameters of the lungs and airways in Korean never-smokers and current or former smokers (“ever-smokers”). Never-smokers (n = 119) and ever-smokers (n = 45) who had normal spirometry and visually normal chest computed tomography (CT) results were retrospectively enrolled in this study. For quantitative CT analyses, the low attenuation area (LAA) of LAA{sub I-950}, LAA{sub E-856}, CT attenuation value at the 15th percentile, mean lung attenuation (MLA), bronchial wall thickness of inner perimeter of a 10 mm diameter airway (Pi10), total lung capacity (TLC{sub CT}), and functional residual capacity (FRC{sub CT}) were calculated based on inspiratory and expiratory CT images. To compare the results between groups according to age, sex, and smoking history, independent t test, one way ANOVA, correlation test, and simple and multiple regression analyses were performed. The values of attenuation parameters and volume on inspiratory and expiratory quantitative computed tomography (QCT) were significantly different between males and females (p < 0.001). The MLA and the 15th percentile value on inspiratory QCT were significantly lower in the ever-smoker group than in the never-smoker group (p < 0.05). On expiratory QCT, all lung attenuation parameters were significantly different according to the age range (p < 0.05). Pi10 in ever-smokers was significantly correlated with forced expiratory volume in 1 second/forced vital capacity (r = −0.455, p = 0.003). In simple and multivariate regression analyses, TLC{sub CT}, FRC{sub CT}, and age showed significant associations with lung attenuation (p < 0.05), and only TLC{sub CT} was significantly associated with inspiratory Pi10. In Korean subjects with normal spirometry and visually normal chest CT, there may be significant differences in QCT parameters according to sex, age, and smoking history.

  13. CT quantification of lung and airways in normal Korean subjects

    International Nuclear Information System (INIS)

    Kim, Song Soo; Lee, Jeong Eun; Shin, Hye Soo; Jin, Gong Yong; Li, Yuan Zhe

    2017-01-01

    To measure and compare the quantitative parameters of the lungs and airways in Korean never-smokers and current or former smokers (“ever-smokers”). Never-smokers (n = 119) and ever-smokers (n = 45) who had normal spirometry and visually normal chest computed tomography (CT) results were retrospectively enrolled in this study. For quantitative CT analyses, the low attenuation area (LAA) of LAA_I_-_9_5_0, LAA_E_-_8_5_6, CT attenuation value at the 15th percentile, mean lung attenuation (MLA), bronchial wall thickness of inner perimeter of a 10 mm diameter airway (Pi10), total lung capacity (TLC_C_T), and functional residual capacity (FRC_C_T) were calculated based on inspiratory and expiratory CT images. To compare the results between groups according to age, sex, and smoking history, independent t test, one way ANOVA, correlation test, and simple and multiple regression analyses were performed. The values of attenuation parameters and volume on inspiratory and expiratory quantitative computed tomography (QCT) were significantly different between males and females (p < 0.001). The MLA and the 15th percentile value on inspiratory QCT were significantly lower in the ever-smoker group than in the never-smoker group (p < 0.05). On expiratory QCT, all lung attenuation parameters were significantly different according to the age range (p < 0.05). Pi10 in ever-smokers was significantly correlated with forced expiratory volume in 1 second/forced vital capacity (r = −0.455, p = 0.003). In simple and multivariate regression analyses, TLC_C_T, FRC_C_T, and age showed significant associations with lung attenuation (p < 0.05), and only TLC_C_T was significantly associated with inspiratory Pi10. In Korean subjects with normal spirometry and visually normal chest CT, there may be significant differences in QCT parameters according to sex, age, and smoking history

  14. Integration of IC/EC systems in ITER

    International Nuclear Information System (INIS)

    Gassmann, T.; Beaumont, B.; Baruah, U.K.; Bonicelli, T.; Chiocchio, S.; Cox, D.; Darbos, C.; Decamps, H.; Denisov, G.; Henderson, M.; Kazarian, F.; Lamalle, P.U.; Mukherjee, A.; Rasmussen, D.; Saibene, G.; Sartori, R.; Sakamoto, K.; Tanga, A.

    2010-01-01

    The RF heating and current drive (H and CD) systems that are to be installed in ITER during the construction phase, are the electron cyclotron (EC) and ion cyclotron (IC) systems. They are complex assemblies of high voltage power supplies (HVPS), RF generators, transmission lines and antennas. Their design and integration are constrained by many interfaces, both internal, between the subsystems, and external, with the other ITER systems. In addition, some components must be compatible with a nuclear environment and are classified as Safety Important Component. This paper describes the processes implemented in ITER to ensure proper integration.

  15. SpinlineTM, Benefits of a nuclear specific safety-critical digital I/C platform - 15102

    International Nuclear Information System (INIS)

    Duthou, A.; Mouly, P.; Jegou, H.

    2015-01-01

    Spinline TM is Rolls-Royce modular and digital solution dedicated to developing and/or upgrading safety I/C used in nuclear reactors. From the start, Spinline TM was specifically designed for Nuclear applications. Therefore, its architecture and components satisfy, from design, the most stringent safety standards required by the local Safety authorities, while they can be adapted to various types of reactors. This is a significant advantage over suppliers who tried to adapt industrial systems to the Nuclear constraints and faced unexpected delays and costs to meet Safety authorities requirements. Spinline TM was specifically designed to implement any Class 1E and category A IEC-61226 safety I/C functions. It is qualified according to European and French nuclear standard and more recently by the US NRC, notably thanks to its Fail-safe features, deterministic behavior and Physical and Functional Separation. In 2011 EDF chose Spinline TM as its safety I/C systems technology for the modernization of 20 units of its 1300 MW PWR fleet

  16. The optical design of 3D ICs for smartphone and optro-electronics sensing module

    Science.gov (United States)

    Huang, Jiun-Woei

    2018-03-01

    Smartphone require limit space for image system, current lens, used in smartphones are refractive type, the effective focal length is limited the thickness of phone physical size. Other, such as optro-electronics sensing chips, proximity optical sensors, and UV indexer chips are integrated into smart phone with limit space. Due to the requirement of multiple lens in smartphone, proximity optical sensors, UV indexer and other optro-electronics sensing chips in a limited space of CPU board in future smart phone, optro-electronics 3D IC's integrated with optical lens or components may be a key technology for 3 C products. A design for reflective lens is fitted to CMOS, proximity optical sensors, UV indexer and other optro-electronics sensing chips based on 3-D IC. The reflective lens can be threes times of effective focal lens, and be able to resolve small object. The system will be assembled and integrated in one 3-D IC more easily.

  17. Measures of interaction contrast (biological interaction) - ic, ici and icp

    DEFF Research Database (Denmark)

    2015-01-01

    in Hosmer & Lemeshow (1992) and Alfredsson et all (2005) purely in Stata.These two sources however both uses odds ratios as approximations for relational risks. This code on the other hand opens up for using proper estimates of relational risks. To install type "ssc install ic" in the Stata command...

  18. Unique structure of iC3b resolved at a resolution of 24 Å by 3D-electron microscopy.

    Science.gov (United States)

    Alcorlo, Martin; Martínez-Barricarte, Ruben; Fernández, Francisco J; Rodríguez-Gallego, César; Round, Adam; Vega, M Cristina; Harris, Claire L; de Cordoba, Santiago Rodríguez; Llorca, Oscar

    2011-08-09

    Activation of C3, deposition of C3b on the target surface, and subsequent amplification by formation of a C3-cleaving enzyme (C3-convertase; C3bBb) triggers the effector functions of complement that result in inflammation and cell lysis. Concurrently, surface-bound C3b is proteolyzed to iC3b by factor I and appropriate cofactors. iC3b then interacts with the complement receptors (CR) of the Ig superfamily, CR2 (CD21), CR3 (CD11b/CD18), and CR4 (CD11c/CD18) on leukocytes, down-modulating inflammation, enhancing B cell-mediated immunity, and targeting pathogens for clearance by phagocytosis. Using EM and small-angle X-ray scattering, we now present a medium-resolution structure of iC3b (24 Å). iC3b displays a unique conformation with structural features distinct from any other C3 fragment. The macroglobulin ring in iC3b is similar to that in C3b, whereas the TED (thioester-containing domain) domain and the remnants of the CUB (complement protein subcomponents C1r/C1s, urchin embryonic growth factor and bone morphogenetic protein 1) domain have moved to locations more similar to where they were in native C3. A consequence of this large conformational change is the disruption of the factor B binding site, which renders iC3b unable to assemble a C3-convertase. This structural model also justifies the decreased interaction between iC3b and complement regulators and the recognition of iC3b by the CR of the Ig superfamily, CR2, CR3, and CR4. These data further illustrate the extraordinary conformational versatility of C3 to accommodate a great diversity of functional activities.

  19. Composition of Essential Oils and Ethanol Extracts of the Leaves of Lippia Species: Identification, Quantitation and Antioxidant Capacity

    Directory of Open Access Journals (Sweden)

    Maria T.S. Trevisan

    2016-01-01

    Full Text Available The principal components of essential oils, obtained by steam-hydrodistillation from the fresh leaves of five species of the genus Lippia, namely Lippia gracilis AV, Lippia sidoides Mart , Lippia alba carvoneifera, Lippia alba citralifera and Lippia alba myrceneifera and ethanol extracts , were evaluated. The greater antioxidant capacity (IC 50 = 980 µg/mL; p 2000 µg/mL. Major compounds in the oils were, thymol (Lippia sidoides Mart, 13.1 g/k, carvone (Lippia alba carvoneifera, 9.6 g/kg, geranial ( Lippia alba citraleifera, 4.61 g/kg; Lippiaalba myrceneifera, 1.6 g/kg, neral ( Lippia alba citraleifera, 3.4 g/kg; Lippia alba myrceneifera, 1.16 g/k, carvacrol (Lippia gracilis AV, 5.36 g/kg and limonene (Lippia alba carvoneifera, 5.14 g/kg. Of these, carvone (IC 50 = 330 µM along with thymol (1.88 units, and carvacrol (1.74 units, were highly active in the hypoxanthine/xanthine oxidase, and ORAC assays respectively. The following compounds namely I: calceolarioside E, II: acteoside, III: isoacteoside, IV: luteolin, V: 5,7,3´,4´-tetrahydroxy-3,6-dimethoxy flavone (spinacetin , VI: naringenin, VII: apigenin, VIII: 6-methoxy apigenin (hispidulin, IX: 5,7,3´-trihydroxy-3,6,4´-trimethoxy flavone , X:5,7,4´-trihydroxy-3,6-dimethoxy flavone , XI: naringenin-4´-methyl ether, XII: 5,7-dihydroxy-3,6,4´-trimethoxy flavone (santin , XIII:5,7-dihydroxy-6,4´-dimethoxy-flavone (pectolinaringenin and XIV: 5-hydroxy-3,7,4´-trimethoxy flavone were identified in the ethanol extracts . Of the leaf ethanol extracts, strong antioxidant capacity was only evident in that of Lippia alba carvoneifera (IC 50 = 1.23 mg/mL. Overall, the data indicates that use of the leaves of Lippia species in food preparations, should be beneficial to health.

  20. Uploading, Searching and Visualizing of Paleomagnetic and Rock Magnetic Data in the Online MagIC Database

    Science.gov (United States)

    Minnett, R.; Koppers, A.; Tauxe, L.; Constable, C.; Donadini, F.

    2007-12-01

    The Magnetics Information Consortium (MagIC) is commissioned to implement and maintain an online portal to a relational database populated by both rock and paleomagnetic data. The goal of MagIC is to archive all available measurements and derived properties from paleomagnetic studies of directions and intensities, and for rock magnetic experiments (hysteresis, remanence, susceptibility, anisotropy). MagIC is hosted under EarthRef.org at http://earthref.org/MAGIC/ and will soon implement two search nodes, one for paleomagnetism and one for rock magnetism. Currently the PMAG node is operational. Both nodes provide query building based on location, reference, methods applied, material type and geological age, as well as a visual map interface to browse and select locations. Users can also browse the database by data type or by data compilation to view all contributions associated with well known earlier collections like PINT, GMPDB or PSVRL. The query result set is displayed in a digestible tabular format allowing the user to descend from locations to sites, samples, specimens and measurements. At each stage, the result set can be saved and, where appropriate, can be visualized by plotting global location maps, equal area, XY, age, and depth plots, or typical Zijderveld, hysteresis, magnetization and remanence diagrams. User contributions to the MagIC database are critical to achieving a useful research tool. We have developed a standard data and metadata template (version 2.3) that can be used to format and upload all data at the time of publication in Earth Science journals. Software tools are provided to facilitate population of these templates within Microsoft Excel. These tools allow for the import/export of text files and provide advanced functionality to manage and edit the data, and to perform various internal checks to maintain data integrity and prepare for uploading. The MagIC Contribution Wizard at http://earthref.org/MAGIC/upload.htm executes the upload

  1. Polyphenol content and antioxidant capacity in organically and conventionally grown vegetables

    Directory of Open Access Journals (Sweden)

    Kevser Unal

    2014-11-01

    Full Text Available Objective: To evaluate the polyphenol content and antioxidant capacity of ethanol extracts of some organically and conventionally grown leafy vegetables. Methods: The ethanol extracts of kailan (Brassica alboglabra, bayam (Amaranthus spp. and sawi (Brassica parachinensis were tested for total phenolic content (TPC, total flavonoid content (TFC, and total anthocyanin content (TAC and the antioxidant capacity of the extracts measured using 2,2-diphenyl-1-picrylhydrazyl assay. Results: In TPC test, sawi extract showed the highest phenolic content while bayam contained the least phenolic content for both organically and conventionally grown types. In TFC test, organically grown sawi extract showed the highest flavonoid content, while organically grown kailan extract showed the least flavonoid content among all types of vegetables. The flavonoid content of the conventionally grown types of vegetable extracts was the highest in kalian and the least in sawi. For 2,2-diphenyl-1-picrylhydrazyl radical scavenging activity, the activity increased with the increasing concentration of each extract. All conventionally grown vegetable extracts showed higher antioxidant activity compared to their organically grown counterparts. Extracts of conventionally grown sawi showed the highest percentage inhibition followed by conventionally grown kailan and organically grown sawi. There were no correlation between TPC, TFC, TAC and IC25 of both organically and conventionally grown vegetables. However, there was a correlation between TAC and IC25 of conventionally grown vegetable extracts. The results showed relatively similar polyphenol content between organically and conventionally grown vegetable extracts. However, the conventionally grown vegetables extracts generally have higher antioxidant activity compared to the organically grown extracts. Conclusions: These results suggested that the different types of agricultural practice had a significant contribution to the

  2. Anatomy of a merger - CO in Arp 299 (IC 694-NGC 3690)

    International Nuclear Information System (INIS)

    Sargent, A.; Scoville, N.

    1991-01-01

    High-resolution (2.4-arcsec) CO observations of the interacting system Arp 299 (Mrk 171: IC 694 and NGC 3690) reveal major gas condensations at the nuclei of both galaxies and in the disk overlap region. The 0.9 x 10 to the 9th solar masses of H2 at the nucleus of NGC 3690 extends to radii of 310 pc and probably sustains a starburst. A compact source (radius not greater than 250 pc) of mass 3.9 x 10 to the 9th solar masses is found at the nucleus of IC 694; this galaxy may harbor an AGN. At least three discrete subcondensations, probably active star-forming knots, are detected in the 1800 x 640 pc overlap region. 24 refs

  3. A cell-level power management IC in BCD-SOI for partial power processing in Concentrating-PV systems

    NARCIS (Netherlands)

    Zaman, M.S.; Wen, Y.; Fernandes, R.; Buter, B.; Doorn, T.S.; Dijkstra, M.; Bergveld, H.J.; Trescases, O.

    2014-01-01

    This work presents a power management IC used to mitigate the effects of mismatch in Concentrating-Photovoltaic (CPV) systems. The IC contains a bi-directional dc-dc converter, an auxiliary boost converter to generate the internal 10 V power supply, as well as protection and monitoring circuits. The

  4. Individual receptor profiling as a novel tool to support diagnosis of bladder pain syndrome/interstitial cystitis (BPS/IC).

    Science.gov (United States)

    Neuhaus, Jochen; Schulte-Baukloh, Heinrich; Stolzenburg, Jens-Uwe; Speroni di Fenizio, Pietro; Horn, Lars-Christian; Rüffert, Henrik; Hartenstein, Siegurd; Burger, Maximilian; Schulze, Matthias; Schwalenberg, Thilo

    2012-10-01

    Dysregulation of neurotransmitter receptors may contribute to bladder overactivity (OAB) symptoms. To address the question whether specific receptor expression patterns are associated with bladder pain syndrome/interstitial cystitis (BPS/IC), we examined the expression of muscarinic, purinergic and histamine receptors in the detrusor. Detrusor receptor expression was investigated in bladder biopsies of female BPS/IC patients (n = 44; age 60.64 ± 13.78, mean ± SD) and carcinoma patients (n = 11; age 58.91 ± 12.72) undergoing cystectomy. Protein expression of muscarinic (M2, M3), purinergic (P2X1-3) and histamine receptors (H1, H2) was analysed by confocal immunofluorescence, and gene expression was quantified by real-time polymerase chain reaction (qPCR). M2, P2X1, P2X2 and H1 receptor immunoreactivity (-IR) was significantly enhanced in BPS/IC compared to the control group, while there was no difference for M3-, P2X3- and H2-IR. We calculated a score, which separated BPS/IC from control patients with an AUC of 89.46%, showing 84.09% sensitivity and 90.91% specificity. Patients had a 9.25 times enhanced calculated risk for BPS/IC. In addition, two patient subgroups (M2 > M3 and M3 > M2) were observed, which differed in associated purinergic and histamine receptor expression. M2, P2X1, P2X2 and H1 were significantly upregulated in BPS/IC patients, and H2 was occasionally highly overexpressed. There was no significant correlation between receptor protein and gene expression, implying posttranslational mechanisms being responsible for the altered receptor expressions. On the basis of individual receptor profiles, upregulated receptors could be targeted by monotherapy or combination therapy with already approved receptor inhibitors, thereby promoting tailored therapy for patients suffering from BPS/IC-like symptoms.

  5. The correlation between the paired inspiratory and expiratory three-dimensional quantitative CT and pulmonary function test in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Sui Xi; Song Wei; Xue Huadan; Song Lan; Yang Liang; Jin Zhengyu

    2013-01-01

    Objective: To investigate the correlation between the paired inspiratory and expiratory quantitative CT and pulmonary function tests (PFTs) in patients with chronic obstructive pulmonary disease (COPD). Methods: A total of 84 patients with COPD were enrolled. For each patient, CT scan was performed in deep inspiration and expiration. Using automatic post-processing software, a three-dimension quantitative measurement was employed to assess the CT parameters of emphysema and air trapping. The correlation between CT and PFT was evaluated by the Spearman rank correlation test and multivariate linear regression analysis. Results: The percent 1 [Perc_1, (-984.28 ± 17.93) HU] and percent 15 [Perc_1_5, (-948.35 ± 22.26) HU] from the CT parameters of emphysema were positively correlated with the forced expiratory volume in 1 second predicted (FEV_1%, 48.69 ± 23, 47), the ratio of forced expiratory volume in 1 second over forced vital capacity [FEV_1/FVC, (45.89 ± 15.36)%, r = 0.45-0.67, P < 0.01], was negatively correlated with the ratio of residual volume to total lung capacity [RV/TLC, (61.32 ± 14.48)%]. The other CT parameters of emphysema index (EI) and the parameters of air trapping, the change in relative lung volume with attenuation values from -860 to -950 HU [RVC_-_8_6_0_-_-_9_5_0, (17.66 ± 22.36)%], the expiration to inspiration ratio of mean lung density (MLD_e_x_/_i_n, 0.93 ± 0.06), the expiration to inspiration ratio of lung volume (LV_e_x_/_i_n, 0.71 ± 0.14) had negative correlations with logFEV_1%, FEV_1/FVC (r = -0.48--0.69, P < 0.01) and positive correlations with RV/TLC (r = 0.41-0.66, P < 0.01). The further univariate linear regressions showed that EI, Perc_1, Pere_1_5, RVC_-_8_6_0_-_-_9_5_0, MLD_e_x_/_i_n, LV_e_x_/_i_n were correlated with the parameters of PFTs (R square values of the regression equation, ranged from 0.27 to 0.66, P < 0.01). After the pairwise combinations of the parameters of emphysema and air trapping, multivariate stepwise

  6. H I IMAGING OBSERVATIONS OF SUPERTHIN GALAXIES. II. IC 2233 AND THE BLUE COMPACT DWARF NGC 2537

    International Nuclear Information System (INIS)

    Matthews, Lynn D.; Uson, Juan M.

    2008-01-01

    We have used the Very Large Array to image the H I 21 cm line emission in the edge-on Sd galaxy IC 2233 and the blue compact dwarf NGC 2537. We also present new optical B, R, and Hα imaging of IC 2233 obtained with the WIYN telescope. Despite evidence of localized massive star formation in the form of prominent H II regions and shells, supergiant stars, and a blue integrated color, IC 2233 is a low surface brightness system with a very low global star formation rate (∼ sun yr -1 ), and we detect no significant 21 cm radio continuum emission from the galaxy. The H I and ionized gas disks of IC 2233 are clumpy and vertically distended, with scale heights comparable to that of the young stellar disk. Both the stellar and H I disks of IC 2233 appear flared, and we also find a vertically extended, rotationally anomalous component of H I extending to ∼ 2.4d 10 kpc from the midplane. The H I disk exhibits a mild lopsidedness as well as a global corrugation pattern with a period of ∼7d 10 kpc and an amplitude of ∼150d 10 pc. To our knowledge, this is the first time corrugations of the gas disk have been reported in an external galaxy; these undulations may be linked to bending instabilities or to underlying spiral structure and suggest that the disk is largely self-gravitating. Lying at a projected distance of 16'.7 from IC 2233, NGC 2537 has an H I disk with a bright, tilted inner ring and a flocculent, dynamically cold outer region that extends to ∼3.5 times the extent of the stellar light (D 25 ). Although NGC 2537 is rotationally-dominated, we measure H I velocity dispersions as high as σ V.HI ∼25 km s -1 near its center, indicative of significant turbulent motions. The inner rotation curve rises steeply, implying a strong central mass concentration. Our data indicate that IC 2233 and NGC 2537 do not constitute a bound pair and most likely lie at different distances. We also find no compelling evidence of a recent minor merger in either IC 2233 or NGC

  7. Motor SUS i životna sredina / IC engine and environment

    Directory of Open Access Journals (Sweden)

    Zoran Građin

    2002-03-01

    Full Text Available Ekološki pokreti u svetu su sve aktivniji, zbog stvarne ugroženosti Zemlje Mnogobrojni su oblici i izvori zagađenja, a jedan od najvećih su motori sa unutrašnjim sagorevanjem, za koje se pretpostavlja da će još dugo dominirati kao pogonski agregati u mnogim oblastima primene. U vezi s tim moguće je delovati u dva smera: zamenom konvencionalnih goriva alternativnim i konstrukcionim izmenama na motorima radi smanjenja emisije i potrošnje goriva. Jedna od mogućnosti konstrukcionog poboljšanja motora je i smanjenje mehaničkih gubitaka, koji kod današnjih konstrukcija još uvek imaju znatan udeo u gubicima, pogotovo na parcijalnim režimima. Treba naglasiti da kompleksni problemi smanjenja potrošnje goriva i emisije izduvnih gasova motora (vozila mogu da se reše samo spregom razvoja automobilske i naftne industrije. / Ecological trends and movements in the modern world grow stronger and more active, due to a real danger of Earth pollution. One of the main sources of pollution are IC engines and their influence on environment is significant. However, conventional combustion engines still are and will be dominant powering systems for numerous future applications. Two solutions are possible answers to this problem: first, the replacement of conventional fuels by alternative ones and second, modifications on the IC engine design in order to decrease fuel emission and consumption. One of the solutions for the improvement of IC engine design is the modification of engine parts or their design, with great influence on the decrease of mechanical losses, especially on partial rating. Therefore, it is important to say that complex problems of engine (automotive decrease of fuel consumption and exhaust gas emission can be solved only by simultaneous development of oil and engine (automotive industry.

  8. SN 2009bb: A PECULIAR BROAD-LINED TYPE Ic SUPERNOVA ,

    International Nuclear Information System (INIS)

    Pignata, Giuliano; Stritzinger, Maximilian; Phillips, M. M.; Morrell, Nidia; Boldt, Luis; Campillay, Abdo; Contreras, Carlos; Gonzalez, Sergio; Krzeminski, Wojtek; Roth, Miguel; Salgado, Francisco; Soderberg, Alicia; Mazzali, Paolo; Anderson, J. P.; Folatelli, Gaston; Foerster, Francisco; Hamuy, Mario; Maza, Jose; Levesque, Emily M.; Rest, Armin

    2011-01-01

    Ultraviolet, optical, and near-infrared photometry and optical spectroscopy of the broad-lined Type Ic supernova (SN) 2009bb are presented, following the flux evolution from -10 to +285 days past B-band maximum. Thanks to the very early discovery, it is possible to place tight constraints on the SN explosion epoch. The expansion velocities measured from near maximum spectra are found to be only slightly smaller than those measured from spectra of the prototype broad-lined SN 1998bw associated with GRB 980425. Fitting an analytical model to the pseudobolometric light curve of SN 2009bb suggests that 4.1 ± 1.9 M sun of material was ejected with 0.22 ± 0.06 M sun of it being 56 Ni. The resulting kinetic energy is 1.8 ± 0.7 x 10 52 erg. This, together with an absolute peak magnitude of M B = -18.36 ± 0.44, places SN 2009bb on the energetic and luminous end of the broad-lined Type Ic (SN Ic) sequence. Detection of helium in the early time optical spectra accompanied with strong radio emission and high metallicity of its environment makes SN 2009bb a peculiar object. Similar to the case for gamma-ray bursts (GRBs), we find that the bulk explosion parameters of SN 2009bb cannot account for the copious energy coupled to relativistic ejecta, and conclude that another energy reservoir (a central engine) is required to power the radio emission. Nevertheless, the analysis of the SN 2009bb nebular spectrum suggests that the failed GRB detection is not imputable to a large angle between the line-of-sight and the GRB beamed radiation. Therefore, if a GRB was produced during the SN 2009bb explosion, it was below the threshold of the current generation of γ-ray instruments.

  9. Near-IR TRGB Distance Modulus of Dwarf Irregular Galaxy IC 1613

    Directory of Open Access Journals (Sweden)

    M. Y. Jung

    2009-12-01

    Full Text Available The JHKs magnitudes of the red giant branch tip (TRGB and the distance moduli of the nearby dwarf irregular galaxy IC 1613 have been determined from the nearinfrared luminosity functions (LFs of the resolved stars in the galaxy. Applying a Savitzky-Golay filtering, we derived the second derivatives of the LFs, and estimated the apparent magnitudes of the TRGB as mJ = 19.1, mH = 18.4, and mKs = 18:0. The mean values of the theoretical absolute magnitudes of the TRGB were measured by using the Yonsei-Yale isochrones with a metallicity range of -2.1 < [Fe/H] < -0.5 and age of 12 Gyr. The derived values of near-infrared TRGB distance moduli for IC 1613 are (m-M = 24.12±0:25, 24.20±0.44, and 24.00±0.52 for J;H, and Ks bands, respectively.

  10. The ACS LCID project. X. the star formation history of IC 1613: Revisiting the over-cooling problem

    Energy Technology Data Exchange (ETDEWEB)

    Skillman, Evan D. [Minnesota Institute for Astrophysics, University of Minnesota, Minneapolis, MN 55455 (United States); Hidalgo, Sebastian L.; Monelli, Matteo; Gallart, Carme; Aparicio, Antonio, E-mail: skillman@astro.umn.edu, E-mail: shidalgo@iac.es, E-mail: monelli@iac.es, E-mail: carme@iac.es, E-mail: aparicio@iac.es [Instituto de Astrofísica de Canarias, Vía Láctea s/n, E-38200 La Laguna, Tenerife, Canary Islands (Spain); and others

    2014-05-01

    We present an analysis of the star formation history (SFH) of a field near the half-light radius in the Local Group dwarf irregular galaxy IC 1613 based on deep Hubble Space Telescope Advanced Camera for Surveys imaging. Our observations reach the oldest main sequence turn-off, allowing a time resolution at the oldest ages of ∼1 Gyr. Our analysis shows that the SFH of the observed field in IC 1613 is consistent with being constant over the entire lifetime of the galaxy. These observations rule out an early dominant episode of star formation in IC 1613. We compare the SFH of IC 1613 with expectations from cosmological models. Since most of the mass is in place at early times for low-mass halos, a naive expectation is that most of the star formation should have taken place at early times. Models in which star formation follows mass accretion result in too many stars formed early and gas mass fractions that are too low today (the 'over-cooling problem'). The depth of the present photometry of IC 1613 shows that, at a resolution of ∼1 Gyr, the star formation rate is consistent with being constant, at even the earliest times, which is difficult to achieve in models where star formation follows mass assembly.

  11. Tribološke karakteristike motora SUS / Tribological characteristics of IC engines

    Directory of Open Access Journals (Sweden)

    Zoran B. Građin

    2003-05-01

    Full Text Available Poznato je da se intenzivno teži smanjenju potrošnje goriva kod motora SUS pre svega iz ekoloških razloga. To se postiže primenom raznih konstrukcionih mera, medu kojima su i postupci koji doprinose smanjenju trenja. Da bi se postigao određeni uspeh na tom planu, neophodno je da se poznaju tribološke karakteristike motora u celini, kao i pojedinih sklopova i sistema. Najveći uticaj na trenje u motoru, a time i najveći interes za izučavanje triboloških karakteristika, izazivaju klipna grupa, ležaji kolenastog vratila, sistem razvoda i sistem za podmazivanje. Tribološke karakteristike motora treba poznavati još u fazi konstruisanja motora, jer jedino na taj način maze da se da puni doprinos smanjenju potrošnje goriva i izduvne emisije. / Intensive research for decreasing fuel consumption of IC engines is due wainly to ecologycal reasons. The problem can be solved by applying numerous diferent design solutions, among them methods for friction decrease. In order to achieve any success in that field it is necessary to be familiar with tribological features of a complete engine and its individual parts and assemblies. The main influence on IC engine friction losses comes from the piston group, the cranckshaft bearings, the timing system and the lubrication system. Tribological characteristics have to be determined in the first stage of IC engine design, because this is the only way to give full contribution to the decreasing of fuel consumption and exhaust emission.

  12. Comparison Study on I&C System Architecture of the Third Generation NPP Between EPR 1600 and US-APWR 1700

    International Nuclear Information System (INIS)

    Nafi Feridian; Arief Heru Kuncoro

    2009-01-01

    In order to support government's programs on research and development of nuclear energy, so a comparative study has been conducted on I&C system architecture of the third generation Nuclear Power Plant (NPP) of EPR 1600 and US-APWR 1700. I&C system is one of supporting systems in nuclear power plant in such away that the nuclear reactor operation can be safely and control. This study compares parameters on main structure of I&C system architecture related with safety system of nuclear power plant operation.The methodology of this study are literature study, data collection, review and analysis. It can be concluded although the two system have some have similarities, both of them have implemented a modern digital and computerized I&C system architecture with high ability of safety level and suitable with American code standard. But in general, they have difference parameters, such as classification of safety-related and non safety-related group, control and monitoring system, supporting systems of defence in depth and also supporting systems of I&C safety. (author)

  13. Understanding the phase separation evolution in efficient P3HT:IC70BA-based bulk-heterojunction polymer solar cells

    International Nuclear Information System (INIS)

    Fan Xi; Guo Shishang; Fang Guojia; Li Songzhan

    2013-01-01

    The effects of solvent and thermal annealing on the morphology of the active layers and the photovoltaic performance of bulk-heterojunction (BHJ) polymer solar cells (PSCs) are investigated systematically, for PSCs based on a blend of poly(3-hexylthiophene) (P3HT) as a donor and indene-C 70 bisadduct (IC 70 BA) as an acceptor. IC 70 BA crystallites are found reasonably well dispersed in the P3HT matrix after spin-coating. However, the IC 70 BA crystallites coarsen in size after annealing, which are clearly evidenced by transmission electron microscopy. Simultaneously, space charge limited current measurements demonstrate that solvent and thermal annealing can improve the hole and electron mobility, which reduces charge-carrier recombination and improves charge-carrier transport in the P3HT and IC 70 BA blend layers. The corresponding current-voltage curves are measured in quantity and we propose a model to show the variation of the ordered structure of P3HT domains and IC 70 BA crystallite characteristics in the phase separation process, expressing a viewpoint on the high performance of BHJ PSCs.

  14. On the Significance of Process Comprehension for Conducting Targeted ICS Attacks

    NARCIS (Netherlands)

    Green, Benjamin; Krotofil, Marina; Abbasi, Ali

    2017-01-01

    The exploitation of Industrial Control Systems (ICSs) has been described as both easy and impossible, where is the truth? Post-Stuxnet works have included a plethora of ICS focused cyber security research activities, with topics covering device maturity, network protocols, and overall cyber security

  15. A Novel Small-molecule WNT Inhibitor, IC-2, Has the Potential to Suppress Liver Cancer Stem Cells.

    Science.gov (United States)

    Seto, Kenzo; Sakabe, Tomohiko; Itaba, Noriko; Azumi, Junya; Oka, Hiroyuki; Morimoto, Minoru; Umekita, Yoshihisa; Shiota, Goshi

    2017-07-01

    The presence of cancer stem cells (CSCs) contributes to metastasis, recurrence, and resistance to chemo/radiotherapy in hepatocellular carcinoma (HCC). The WNT signaling pathway is reportedly linked to the maintenance of stemness of CSCs. In the present study, in order to eliminate liver CSCs and improve the prognosis of patients with HCC, we explored whether small-molecule compounds targeting WNT signaling pathway suppress liver CSCs. The screening was performed using cell proliferation assay and reporter assay. We next investigated whether these compounds suppress liver CSC properties by using flow cytometric analysis and sphere-formation assays. A mouse xenograft model transplanted with CD44-positive HuH7 cells was used to examine the in vivo antitumor effect of IC-2. In HuH7 human HCC cells, 10 small-molecule compounds including novel derivatives, IC-2 and PN-3-13, suppressed cell viability and WNT signaling activity. Among them, IC-2 significantly reduced the CD44-positive population, also known as liver CSCs, and dramatically reduced the sphere-forming ability of both CD44-positive and CD44-negative HuH7 cells. Moreover, CSC marker-positive populations, namely CD90-positive HLF cells, CD133-positive HepG2 cells, and epithelial cell adhesion molecule-positive cells, were also reduced by IC-2 treatment. Finally, suppressive effects of IC-2 on liver CSCs were also observed in a xenograft model using CD44-positive HuH7 cells. The novel derivative of small-molecule WNT inhibitor, IC-2, has the potential to suppress liver CSCs and can serve as a promising therapeutic agent to improve the prognosis of patients with HCC. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  16. Evaluation of a Cordia-IC enzyme-linked immunosorbent assay kit for the detection of circulating immune complexes.

    Science.gov (United States)

    Landoy, Z; West, T E; Vladutiu, A O; Fitzpatrick, J E

    1985-01-01

    A commercial kit (Cordia-IC) from Cordis Laboratory, Miami, Fla., was compared with the Raji cell radioimmunoassay for its ability to detect circulating immune complexes (CIC) in sera from 30 control subjects and 118 patients with infectious diseases. The 118 patients were categorized into the following groups: (i) 23 patients with bacterial endocarditis, (ii) 41 patients with bacteremia from an infected intravascular catheter or access device, and (iii) 54 patients with Staphylococcus aureus bacteremia related to a deep tissue infection. The Cordia-IC was comparable to the Raji cell radioimmunoassay in intraassay variability (4.0 versus 8.0%) and interassay reproducibility (8.7 versus 20.0%). Neither assay found CIC amounts above 12.5 micrograms equivalents (eq) of aggregated human gamma globulin (AHG) per ml in any of the 30 control individuals. In group 1, Cordia-IC detected 19 of 23 positives (mean, 73.6 micrograms eq of AHG per ml), whereas the Raji cell detected 16 of 23 positives (mean, 54.8 micrograms eq of AHG per ml). In group 2, Cordia-IC detected 19 of 41 positives (mean, 20.6 micrograms eq of AHG per ml), whereas the Raji cell detected 16 of 41 positives (mean, 15.1 micrograms eq of AHG per ml). In group 3, Cordia-IC found 38 of 54 positives (mean, 28.0 micrograms eq of AHG per ml), whereas the Raji cell found 32 of 54 positives (mean, 23.9 micrograms eq of AHG per ml). Statistically, these findings were not significantly different in any of the three patient groups (P> 0.15), and there was an overall good correlation between the results obtained by the two assays (r+0.64, PCordia-IC provided a suitable assay for the detection of CIC and might find application in routine clinical laboratories. PMID:3897269

  17. Improved CVD Techniques for Depositing Passivation Layers of ICs

    Science.gov (United States)

    1975-10-01

    Halted PhilcoT xong, 43 o Flex b ru.an I ery t92." PrutptEnt,"e Electro nic -News; p. 34 --(M a~y 20, 1974). 355. 4t3fAtil, No 2(estbgru sey SpesHg-o e...and No. 4, 78 (1974). *J. G. Biddle Co., Plymouth Meeting, PA 19462. 222 NARROW AND WIDE INTERFERENCE CONTOUR 2 4 6 IC PE LLET Bonding pad oxide area

  18. 3D Integration of MEMS and IC: Design, technology and simulations

    OpenAIRE

    Schjølberg-Henriksen, Kari

    2009-01-01

    * 3D integration: Opportunities and trends* e-CUBES: Tire pressure monitoring system (TPMS)* Package design including thermo-mechanical modeling* Technology development* Sensor packaging concept* Gold stud bump bonding* Device characterization and testing* Summary and outlook 3D Integration of MEMS and IC: Design, technology and simulations

  19. Casting for infantile scoliosis: the pitfall of increased peak inspiratory pressure.

    Science.gov (United States)

    Dhawale, Arjun A; Shah, Suken A; Reichard, Samantha; Holmes, Laurens; Brislin, Robert; Rogers, Kenneth; Mackenzie, William G

    2013-01-01

    Serial cast correction is a popular treatment option for progressive infantile scoliosis. Body casting can lead to chest and abdominal expansion restriction and result in decreased chest wall compliance. There are no studies evaluating the effects of casting on ventilation in infantile scoliosis. This study examines changes in peak inspiratory pressure (PIP) during serial casting for infantile scoliosis. We retrospectively reviewed data obtained from 37 serial Cotrel elongation, derotation, and flexion cast corrections in patients with infantile scoliosis. Patient demographics, radiographic measurements, and anesthesia data were recorded. Anesthesia technique was standardized: children were intubated with rigid endotracheal tubes (ETTs); tidal volume was held constant at 8 to 10 cm(3)/kg using volume control ventilation; and PIP was recorded at baseline, after cast application before window cutout, and after window cutout before extubation. Any complications were documented. We assessed the PIP changes with a repeated measures analysis of variance (ANOVA). The mean age at first casting was 21.8 months (range, 12 to 42 mo) and mean follow-up since first casting was 22.4 months (range, 13 to 40 mo) with mean major Cobb angle of 53±15 degrees. The mean PIP was 15.5±4.9 cm H(2)O before casting, 31.9±7.9 cm H(2)O after cast application, and 20.4±5.6 cm H2O after making windows. There was a 106% increase after casting and 32% increase after window cutout from the baseline PIP levels. There was a significant difference in PIP on repeated measures ANOVA (Pcasting and another had delayed difficulty in breathing. Casting resulted in an increased PIP due to transient restrictive pulmonary process; after windows were cut out, the PIP reduced but not to baseline. In patients with underlying pulmonary disease, the casting process may induce respiratory complications, and a proper period of observation after casting is necessary. Case series, level 4.

  20. Catalog of Realizations for DXCCII using Commercially Available ICs and Applications

    Directory of Open Access Journals (Sweden)

    S. Maheshwari

    2012-04-01

    Full Text Available This paper presents fifteen distinct practical realizations for dual-X second generation current conveyor (DXCCII using commercially available integrated circuits. Detailed comparisons and results are presented to verify the utility of proposed realizations. The catalog of proposed realizations is a first attempt and is expected to be useful for testing newly developed circuits based on dual-X second generation current conveyor. Each of the first fourteen proposed realizations uses four ICs. One three IC based implementation is further given making the total count fifteen. Some additional features are also explored which further enhance the versatility of DXCCII. The paper further presents a novel and compact quadrature oscillator to verify the applicability of the proposed realizations. Single resistance control of the frequency of oscillation is also demonstrated by employing the new gain-variable DXCCII. Experimental results are also included along with simulation results to validate the proposed theory and its practical significance.

  1. Efeito da fisioterapia sobre os parâmetros ventilatórios e a dinâmica tóraco-abdominal de crianças respiradoras bucais Effects of the physical therapy on ventilatory parameters and thoracoabdominal dynamics of mouth breathing children

    Directory of Open Access Journals (Sweden)

    Fabiana dos Santos Ferreira

    2012-03-01

    Full Text Available Este estudo objetivou avaliar o efeito da fisioterapia nos parâmetros ventilatórios e na dinâmica tóraco-abdominal de crianças respiradoras bucais. Dez crianças respiradoras bucais foram submetidas a um programa de reeducação respiratória e correção postural durante 20 sessões de exercícios de alongamento e fortalecimento muscular sobre a bola suíça, estimulação diafragmática e alongamento dos músculos acessórios da inspiração. Os dados coletados foram as medidas de pressões inspiratórias e expiratórias máximas (PIM e PEM, capacidade inspiratória (CI, pico de fluxo expiratório (PFE, mobilidade torácica por meio do coeficiente respiratório (Cr nos níveis axilar (CrA, xifoide (CrX e umbilical (CrU e análise biofotogramétrica do ângulo de Charpy. Estes foram verificados antes e após 10 e 20 atendimentos. Os dados foram submetidos a uma análise de variância (ANOVA e, nas diferenças encontradas entre as médias, aplicou-se o Teste de Tukey com nível de significância de 5% (pThis study aimed to evaluate the effects of the physiotherapy on the ventilatory parameters and thoracoabdominal dynamics of mouth breathing children. Ten mouth breathing children were undergone to 20 sessions of respiratory reeducation and postural correction through stretching and strengthening exercises on Swiss ball, diaphragmatic stimulation and stretching of the inspiratory accessory muscles. The data collected were measurements of the maximum inspiratory and expiratory pressures (MIP and MEP, inspiratory capacity (IC, peak expiratory flow (PEF, the chest wall mobility measured by the respiratory coefficient (Rc at the levels of the axillary (RcA, xiphosternal (RcX and umbilical (RcU regions and biophotogrametry analysis of the Charpy angle. These were measured before and after 10 and 20 sessions. A 1-way repeated measures analysis of variance (ANOVA was used to determine differences in variables among the three evaluations. Post

  2. 5th International Conference on Mathematical Modeling in Physical Sciences (IC-MSquare 2016)

    International Nuclear Information System (INIS)

    Vagenas, Elias C.; Vlachos, Dimitrios S.

    2016-01-01

    The 5th International Conference on Mathematical Modeling in Physical Sciences (IC- MSQUARE) took place at Athens, Greece, from Monday, 23"t"h of May, to Thursday, 26"t"h of May 2016. The Conference was attended by more than 130 participants and hosted about 170 oral, poster, and virtual presentations while counted more than 500 pre-registered authors. The 5"t"h IC-MSQUARE consisted of different and diverging workshops and thus covered various research fields where Mathematical Modeling is used, such as Theoretical/Mathematical Physics, Neutrino Physics, Non-Integrable Systems, Dynamical Systems, Computational Nanoscience, Biological Physics, Computational Biomechanics, Complex Networks, Stochastic Modeling, Fractional Statistics, DNA Dynamics, Macroeconomics etc. The scientific program was rather heavy since after the Keynote and Invited Talks in the morning, three parallel oral and one poster session were running every day. However, according to all attendees, the program was excellent with high level talks and the scientific environment was fruitful, thus all attendees had a creative time. We would like to thank the Keynote Speaker and the Invited Speakers for their significant contribution to IC-MSQUARE. We also would like to thank the Members of the International Advisory and Scientific Committees as well as the Members of the Organizing Committee. (paper)

  3. Managing Rock and Paleomagnetic Data Flow with the MagIC Database: from Measurement and Analysis to Comprehensive Archive and Visualization

    Science.gov (United States)

    Koppers, A. A.; Minnett, R. C.; Tauxe, L.; Constable, C.; Donadini, F.

    2008-12-01

    The Magnetics Information Consortium (MagIC) is commissioned to implement and maintain an online portal to a relational database populated by rock and paleomagnetic data. The goal of MagIC is to archive all measurements and derived properties for studies of paleomagnetic directions (inclination, declination) and intensities, and for rock magnetic experiments (hysteresis, remanence, susceptibility, anisotropy). Organizing data for presentation in peer-reviewed publications or for ingestion into databases is a time-consuming task, and to facilitate these activities, three tightly integrated tools have been developed: MagIC-PY, the MagIC Console Software, and the MagIC Online Database. A suite of Python scripts is available to help users port their data into the MagIC data format. They allow the user to add important metadata, perform basic interpretations, and average results at the specimen, sample and site levels. These scripts have been validated for use as Open Source software under the UNIX, Linux, PC and Macintosh© operating systems. We have also developed the MagIC Console Software program to assist in collating rock and paleomagnetic data for upload to the MagIC database. The program runs in Microsoft Excel© on both Macintosh© computers and PCs. It performs routine consistency checks on data entries, and assists users in preparing data for uploading into the online MagIC database. The MagIC website is hosted under EarthRef.org at http://earthref.org/MAGIC/ and has two search nodes, one for paleomagnetism and one for rock magnetism. Both nodes provide query building based on location, reference, methods applied, material type and geological age, as well as a visual FlashMap interface to browse and select locations. Users can also browse the database by data type (inclination, intensity, VGP, hysteresis, susceptibility) or by data compilation to view all contributions associated with previous databases, such as PINT, GMPDB or TAFI or other user

  4. Somato-motor haptic processing in posterior inner perisylvian region (SII/pIC of the macaque monkey.

    Directory of Open Access Journals (Sweden)

    Hiroaki Ishida

    Full Text Available The posterior inner perisylvian region including the secondary somatosensory cortex (area SII and the adjacent region of posterior insular cortex (pIC has been implicated in haptic processing by integrating somato-motor information during hand-manipulation, both in humans and in non-human primates. However, motor-related properties during hand-manipulation are still largely unknown. To investigate a motor-related activity in the hand region of SII/pIC, two macaque monkeys were trained to perform a hand-manipulation task, requiring 3 different grip types (precision grip, finger exploration, side grip both in light and in dark conditions. Our results showed that 70% (n = 33/48 of task related neurons within SII/pIC were only activated during monkeys' active hand-manipulation. Of those 33 neurons, 15 (45% began to discharge before hand-target contact, while the remaining neurons were tonically active after contact. Thirty-percent (n = 15/48 of studied neurons responded to both passive somatosensory stimulation and to the motor task. A consistent percentage of task-related neurons in SII/pIC was selectively activated during finger exploration (FE and precision grasping (PG execution, suggesting they play a pivotal role in control skilled finger movements. Furthermore, hand-manipulation-related neurons also responded when visual feedback was absent in the dark. Altogether, our results suggest that somato-motor neurons in SII/pIC likely contribute to haptic processing from the initial to the final phase of grasping and object manipulation. Such motor-related activity could also provide the somato-motor binding principle enabling the translation of diachronic somatosensory inputs into a coherent image of the explored object.

  5. Ethnobotany of the Sierra Nevada del Cocuy-Güicán

    NARCIS (Netherlands)

    Rodríguez, Mireia Alcántara; Angueyra, Andrea; Cleef, Antoine M.; Andel, van Tinde

    2018-01-01

    Background: The Sierra Nevada del Cocuy-Güicán in the Colombian Andes is protected as a National Natural Park since 1977 because of its fragile páramo ecosystems, extraordinary biodiversity, high plant endemism, and function as water reservoir. The vegetation on this mountain is threatened by

  6. Antioxidant Capacity and Metal Content of Physalis Peruviana L. Fruit Sold in Markets

    Directory of Open Access Journals (Sweden)

    Ayse Eken

    2014-12-01

    Full Text Available Aim: The dietary intake of medicinal food with antioxidant activity and required amounts of trace elements is important to pursue good healthy life. In our study, we aimed to determine the antioxidant capacity and metal content of goldenberry (Physalis peruviana L. fruit sold in markets in Kayseri. Material and Method: The antioxidant capacity of P. peruviana fruit was determined by the 2,2-diphenyl-1-picrylhydrazyl (DPPH free radical scavenging assay. The DPPH radical scavenger capacity of the methanol extract of fruit was compared with known antioxidants such as ascorbic acid, gallic acid, and butylated hydroxytoluene (BHT as references. The metal content of P. peruviana fruit was measured by using atomic absorption spectrometer (AAS. Results: The fruit of P. peruviana was found to possess DPPH free radical scavenging activity but the antioxidant capacity was lower than the standard substances. Inhibitory concentration 50% (IC50 values of P. peruviana, ascorbic acid, gallic acid, and BHT were determined as 32 mg/ml, 3.8 mg/ml, 3.51 mg/ml, and 1.21 mg/ml, respectively. As a result of the analysis by AAS, it was observed that P. peruviana fruit contented plentiful trace elements and the content of heavy metal was small amount or not detected. Discussion: These observations suggest that the fruit of P. peruviana has a potential source of antioxidant and trace elements of natural origin.

  7. Repercussões da cardiomegalia na função pulmonar de indivíduos adultos com insuficiência cardíaca crônica: uma revisão sistemática Repercussions of the cardiomegaly on the pulmonary function of adult individuals with chronic heart failure: a systematic review

    Directory of Open Access Journals (Sweden)

    João Danyell Dantas da Silva

    2011-03-01

    and 64 years accepting samples with congestive HF and dilated cardiomyopathy and excluding with acute heart failure, post-intervention assessment clinic or by exercise. The quality of papers was evaluated by using the scale of Agency for Healthcare Research and Quality (AHRQ and accepted papers with score>50 points (0-100. We selected 5 studies from total of 1093 and grouped by parameters related to flows and lung volumes, respiratory pattern and muscle performance. At AHRQ, two studies were in the range of 50-75% and the others>75%. These studies showed lower inspiratory vital capacity (IVC, forced expiratory volume in 1st second (FEV1 and maximal inspiratory pressure (PImáx as a function of cardiomegaly, with a slight reduction in the ratio VEF1/IVC and diffusion capacity for carbon monoxide (DLCO. Therefore, the studies suggest that the cardiomegaly leads to a restrictive lung pattern, with reduction in alveolar volume that interferes with DLCO. The strongest correlations involve the reduction of PImáx, IVC and FEV1 in this population.

  8. System reduction for nanoscale IC design

    CERN Document Server

    2017-01-01

    This book describes the computational challenges posed by the progression toward nanoscale electronic devices and increasingly short design cycles in the microelectronics industry, and proposes methods of model reduction which facilitate circuit and device simulation for specific tasks in the design cycle. The goal is to develop and compare methods for system reduction in the design of high dimensional nanoelectronic ICs, and to test these methods in the practice of semiconductor development. Six chapters describe the challenges for numerical simulation of nanoelectronic circuits and suggest model reduction methods for constituting equations. These include linear and nonlinear differential equations tailored to circuit equations and drift diffusion equations for semiconductor devices. The performance of these methods is illustrated with numerical experiments using real-world data. Readers will benefit from an up-to-date overview of the latest model reduction methods in computational nanoelectronics.

  9. Self-Patterning of Silica/Epoxy Nanocomposite Underfill by Tailored Hydrophilic-Superhydrophobic Surfaces for 3D Integrated Circuit (IC) Stacking.

    Science.gov (United States)

    Tuan, Chia-Chi; James, Nathan Pataki; Lin, Ziyin; Chen, Yun; Liu, Yan; Moon, Kyoung-Sik; Li, Zhuo; Wong, C P

    2017-03-15

    As microelectronics are trending toward smaller packages and integrated circuit (IC) stacks nowadays, underfill, the polymer composite filled in between the IC chip and the substrate, becomes increasingly important for interconnection reliability. However, traditional underfills cannot meet the requirements for low-profile and fine pitch in high density IC stacking packages. Post-applied underfills have difficulties in flowing into the small gaps between the chip and the substrate, while pre-applied underfills face filler entrapment at bond pads. In this report, we present a self-patterning underfilling technology that uses selective wetting of underfill on Cu bond pads and Si 3 N 4 passivation via surface energy engineering. This novel process, fully compatible with the conventional underfilling process, eliminates the issue of filler entrapment in typical pre-applied underfilling process, enabling high density and fine pitch IC die bonding.

  10. A novel application of t-statistics to objectively assess the quality of IC50 fits for P-glycoprotein and other transporters.

    Science.gov (United States)

    O'Connor, Michael; Lee, Caroline; Ellens, Harma; Bentz, Joe

    2015-02-01

    Current USFDA and EMA guidance for drug transporter interactions is dependent on IC50 measurements as these are utilized in determining whether a clinical interaction study is warranted. It is therefore important not only to standardize transport inhibition assay systems but also to develop uniform statistical criteria with associated probability statements for generation of robust IC50 values, which can be easily adopted across the industry. The current work provides a quantitative examination of critical factors affecting the quality of IC50 fits for P-gp inhibition through simulations of perfect data with randomly added error as commonly observed in the large data set collected by the P-gp IC50 initiative. The types of errors simulated were (1) variability in replicate measures of transport activity; (2) transformations of error-contaminated transport activity data prior to IC50 fitting (such as performed when determining an IC50 for inhibition of P-gp based on efflux ratio); and (3) the lack of well defined "no inhibition" and "complete inhibition" plateaus. The effect of the algorithm used in fitting the inhibition curve (e.g., two or three parameter fits) was also investigated. These simulations provide strong quantitative support for the recommendations provided in Bentz et al. (2013) for the determination of IC50 values for P-gp and demonstrate the adverse effect of data transformation prior to fitting. Furthermore, the simulations validate uniform statistical criteria for robust IC50 fits in general, which can be easily implemented across the industry. A calibration of the t-statistic is provided through calculation of confidence intervals associated with the t-statistic.

  11. NASA Ames’ COSmIC Laboratory Astrophysics Facility: Recent Results and Progress

    Science.gov (United States)

    Salama, Farid; Sciamma-O'Brien, Ella; Bejaoui, Salma

    2018-06-01

    The COSmIC facility was developed at NASA Ames to study interstellar, circumstellar and planetary analogs in the laboratory [1, 2]. COSmIC stands for “Cosmic Simulation Chamber” and is dedicated to the study of molecules, ions and nanoparticles under the low temperature and high vacuum conditions that are required to simulate space environments. COSmIC integrates a variety of instruments that allow generating; processing and monitoring simulated space conditions in the laboratory. It is composed of a Pulsed Discharge Nozzle expansion that generates a plasma in a free supersonic jet expansion coupled to high-sensitivity, complementary in situ diagnostic tools, used for the detection and characterization of the species present in the expansion: a Cavity Ring Down Spectroscopy (CRDS) and fluorescence spectroscopy systems for photonic detection, and a Reflectron Time-Of-Flight Mass Spectrometer (ReTOF-MS) for mass detection [3, 4].Recent advances achieved in laboratory astrophysics using COSmIC will be presented, in particular in the domain of the diffuse interstellar bands (DIBs) [5, 6] and the monitoring, in the laboratory, of the formation of dust grains and aerosols from their gas-phase molecular precursors in environments as varied as circumstellar outflows [7] and planetary atmospheres [8, 9, 10]. Plans for future laboratory experiments on cosmic molecules and grains in the growing field of laboratory astrophysics (NIR-MIR CRDS, Laser Induced Fluorescence spectra of cosmic molecule analogs and the laser induced incandescence spectra of cosmic grain analogs) will also be addressed as well as the implications for astronomy.References: [1] Salama F., Proceed. IAU S251, Kwok & Sandford eds. CUP, 4, 357 (2008).[2] Salama F., et al., Proceed. IAU S332, Y. Aikawa, M. Cunningham, T. Millar, eds., CUP (2018)[3] Biennier L., et al., J. Chem. Phys., 118, 7863 (2003)[4] Ricketts C. et al. IJMS, 300, 26 (2011)[5] Salama F., et al., ApJ., 728, 154 (2011)[6] EDIBLES

  12. Radio Jets Clearing the Way Through a Galaxy: Watching Feedback in Action in the Seyfert Galaxy IC 5063

    NARCIS (Netherlands)

    Morganti, R.; Oosterloo, T. A.; Oonk, J. B. R.; Frieswijk, W.; Tadhunter, C. N.

    2015-01-01

    High-resolution (0.5 arcsec) CO(2-1) observations performed with the Atacama Large Millimetre/submillimetre Array have been used to trace the kinematics of the molecular gas in the Seyfert 2 galaxy{IC 5063}. Although one of the most radio-loud Seyfert galaxy, IC 5063 is a relatively weak radio

  13. IC 751: A New Changing Look AGN Discovered By NuSTAR

    DEFF Research Database (Denmark)

    Ricci, C.; Bauer, F. E.; Arevalo, P.

    2016-01-01

    We present results of five Nuclear Spectroscopic Telescope Array (NuSTAR) observations of the type 2 active galactic nucleus (AGN) in IC 751, three of which were performed simultaneously with XMM-Newton or Swift/X-Ray Telescope. We find that the nuclear X-ray source underwent a clear transition f...

  14. PmagPy: Software Package for Paleomagnetic Data Analysis and Gateway to the Magnetics Information Consortium (MagIC) Database

    Science.gov (United States)

    Jonestrask, L.; Tauxe, L.; Shaar, R.; Jarboe, N.; Minnett, R.; Koppers, A. A. P.

    2014-12-01

    There are many data types and methods of analysis in rock and paleomagnetic investigations. The MagIC database (http://earthref.org/MAGIC) was designed to accommodate the vast majority of data used in such investigations. Yet getting data from the laboratory into the database, and visualizing and re-analyzing data downloaded from the database, makes special demands on data formatting. There are several recently published programming packages that deal with single types of data: demagnetization experiments (e.g., Lurcock et al., 2012), paleointensity experiments (e.g., Leonhardt et al., 2004), and FORC diagrams (e.g., Harrison et al., 2008). However, there is a need for a unified set of open source, cross-platform software that deals with the great variety of data types in a consistent way and facilitates importing data into the MagIC format, analyzing them and uploading them into the MagIC database. The PmagPy software package (http://earthref.org/PmagPy/cookbook/) comprises a such a comprehensive set of tools. It facilitates conversion of many laboratory formats into the common MagIC format and allows interpretation of demagnetization and Thellier-type experimental data. With some 175 programs and over 250 functions, it can be used to create a wide variety of plots and allows manipulation of downloaded data sets as well as preparation of new contributions for uploading to the MagIC database.

  15. PREFACE: 3rd International Conference on Mathematical Modeling in Physical Sciences (IC-MSQUARE 2014)

    Science.gov (United States)

    2015-01-01

    The third International Conference on Mathematical Modeling in Physical Sciences (IC-MSQUARE) took place at Madrid, Spain, from Thursday 28 to Sunday 31 August 2014. The Conference was attended by more than 200 participants and hosted about 350 oral, poster, and virtual presentations. More than 600 pre-registered authors were also counted. The third IC-MSQUARE consisted of different and diverging workshops and thus covered various research fields where Mathematical Modeling is used, such as Theoretical/Mathematical Physics, Neutrino Physics, Non-Integrable Systems, Dynamical Systems, Computational Nanoscience, Biological Physics, Computational Biomechanics, Complex Networks, Stochastic Modeling, Fractional Statistics, DNA Dynamics, Macroeconomics etc. The scientific program was rather heavy since after the Keynote and Invited Talks in the morning, three parallel oral sessions and one poster session were running every day. However, according to all attendees, the program was excellent with high level of talks and the scientific environment was fruitful, thus all attendees had a creative time. We would like to thank the Keynote Speaker and the Invited Speakers for their significant contribution to IC-MSQUARE. We also would like to thank the Members of the International Advisory and Scientific Committees as well as the Members of the Organizing Committee.

  16. The MusIC method: a fast and quasi-optimal solution to the muscle forces estimation problem

    OpenAIRE

    Muller , Antoine; Pontonnier , Charles; Dumont , Georges

    2018-01-01

    International audience; The present paper aims at presenting a fast and quasi-optimal method of muscle forces estimation: the MusIC method. It consists in interpolating a first estimation in a database generated offline thanks to a classical optimization problem, and then correcting it to respect the motion dynamics. Three different cost functions – two polynomial criteria and a min/max criterion – were tested on a planar musculoskeletal model. The MusIC method provides a computation frequenc...

  17. Cardiovascular disease events and its predictors in women: Isfahan Cohort Study (ICS

    Directory of Open Access Journals (Sweden)

    Masoumeh Sadeghi

    2017-09-01

    Conclusion: In ICS, HTN, diabetes mellitus and high triglyceride are strong predictors for CV events in Iranian women. As almost all strong risk markers of CVD events are preventable, health policy makers have to give urgent consideration to make preventive public health strategies.

  18. IC-tagged proteins are able to interact with each other and perform complex reactions when integrated into muNS-derived inclusions.

    Science.gov (United States)

    Brandariz-Nuñez, Alberto; Otero-Romero, Iria; Benavente, Javier; Martinez-Costas, Jose M

    2011-09-20

    We have recently developed a versatile tagging system (IC-tagging) that causes relocation of the tagged proteins to ARV muNS-derived intracellular globular inclusions. In the present study we demonstrate (i) that the IC-tag can be successfully fused either to the amino or carboxyl terminus of the protein to be tagged and (ii) that IC-tagged proteins are able to interact between them and perform complex reactions that require such interactions while integrated into muNS inclusions, increasing the versatility of the IC-tagging system. Also, our studies with the DsRed protein add some light on the structure/function relationship of the evolution of DsRed chromophore. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Two families from New England with usher syndrome type IC with distinct haplotypes.

    Science.gov (United States)

    DeAngelis, M M; McGee, T L; Keats, B J; Slim, R; Berson, E L; Dryja, T P

    2001-03-01

    To search for patients with Usher syndrome type IC among those with Usher syndrome type I who reside in New England. Genotype analysis of microsatellite markers closely linked to the USH1C locus was done using the polymerase chain reaction. We compared the haplotype of our patients who were homozygous in the USH1C region with the haplotypes found in previously reported USH1C Acadian families who reside in southwestern Louisiana and from a single family residing in Lebanon. Of 46 unrelated cases of Usher syndrome type I residing in New England, two were homozygous at genetic markers in the USH1C region. Of these, one carried the Acadian USH1C haplotype and had Acadian ancestors (that is, from Nova Scotia) who did not participate in the 1755 migration of Acadians to Louisiana. The second family had a haplotype that proved to be the same as that of a family with USH1C residing in Lebanon. Each of the two families had haplotypes distinct from the other. This is the first report that some patients residing in New England have Usher syndrome type IC. Patients with Usher syndrome type IC can have the Acadian haplotype or the Lebanese haplotype compatible with the idea that at least two independently arising pathogenic mutations have occurred in the yet-to-be identified USH1C gene.

  20. The Carnegie Hubble Program: The Infrared Leavitt Law in IC 1613

    Science.gov (United States)

    Scowcroft, Victoria; Freedman, Wendy L.; Madore, Barry F.; Monson, Andrew J.; Persson, S. E.; Seibert, Mark; Rigby, Jane R.; Melbourne, Jason

    2013-01-01

    We have observed the dwarf galaxy IC 1613 at multiple epochs in the midinfrared using Spitzer and the in the near-infrared using the new FourStar near-IR camera on Magellan. We have constructed Cepheid period luminosity relations in the J, H, Ks, [3.6] and [4.5] bands and have used the run of their apparent distance moduli as a function of wavelength to derive the line of sight reddening and distance to IC 1613. Using a nineband fit, we find E(BV ) = 0.050.01 mag and an extinction corrected distance modulus of 0 = 24.29 0.03statistical 0.03systematic mag. By comparing our multiband and [3.6] distance moduli to results from the tip of the red giant branch and red clump distance indicators, we find that metallicity has no measurable effect on Cepheid distances at 3.6 m in the metallicity range 1.0 [Fe/H] 0.2, hence derivations of the Hubble constant at this wavelength require no correction for metallicity.

  1. Antioxidant capacity and fatty acid profile of Centaurea kotschyi (Boiss. and Heldr.) Hayek var. persica (Boiss.) Wagenitz from Turkey

    Energy Technology Data Exchange (ETDEWEB)

    Zengin, G.; Guler, G.O.; Cakmak, Y.S.; Aktumseka, A.

    2011-07-01

    The antioxidant capacity of the methanolic extract and the fatty acid composition of C. kotschyi var. persica were investigated. Six different chemical methods were used to determine the antioxidant capacity. The fatty acid composition was analyzed using gas chromatography. The IC50 value of the extract was determined as 37.09 ig/ml (in the DPPH assay). In the {beta}carotene/linoleic acid system, the extract exhibited 65.22% inhibition against linoleic acid oxidation. The amount of total phenolic content and total antioxidant capacity were detected as 36.52 mg gallic acid equivalent (GAE)/g and 74.93 mg ascorbic acid equivalent (AE)/g, respectively. The major fatty acid in the composition of C. kotschyi var. persica was found to be C 18:3 u3 ({beta}-linolenic acid) by GC analysis. The results presented here indicate that C. kotschyi var. persica possess strong antioxidant properties. Therefore, the species can be used as a natural additive in food, cosmetic and pharmaceutical industries. (Author).

  2. Interpretation of two compact planetary nebulae, IC 4997 and NGC 6572, with aid of theoretical models.

    Science.gov (United States)

    Hyung, S; Aller, L H

    1993-01-15

    Observations of two dense compact planetary nebulae secured with the Hamilton Echelle spectrograph at Lick Observatory combined with previously published UV spectra secured with the International Ultraviolet Explorer enable us to probe the electron densities and temperatures (plasma diagnostics) and ionic concentrations in these objects. The diagnostic diagrams show that no homogenous model will work for these nebulae. NGC 6572 may consist of an inner torordal ring of density 25,000 atoms/cm3 and an outer conical shell of density 10,000 atoms/cm3. The simplest model of IC 4997 suggests a thick inner shell with a density of about 107 atoms/cm3 and an outer envelope of density 10,000 atoms/cm3. The abundances of all elements heavier than He appear to be less than the solar values in NGC 6572, whereas He, C, N, and O may be more abundant in IC 4997 than in the sun. IC 4997 presents puzzling problems.

  3. A search for extragalactic pulsars in the local group galaxies IC 10 and Barnard’s galaxy

    International Nuclear Information System (INIS)

    Al Noori, H; Roberts, M S E; Champion, D; McLaughlin, M; Ransom, Scott; Ray, P S

    2017-01-01

    As of today, more than 2500 pulsars have been found, nearly all in the Milky Way, with the exception of ∼28 pulsars in the Small and Large Magellanic Clouds. However, there have been few published attempts to search for pulsars deeper in our Galactic neighborhood. Two of the more promising Local Group galaxies are IC 10 and NGC 6822 (also known as Barnard’s Galaxy) due to their relatively high star formation rate and their proximity to our galaxy. IC 10 in particular, holds promise as it is the closest starburst galaxy to us and harbors an unusually high number of Wolf-Rayet stars, implying the presence of many neutron stars. We observed IC 10 and NGC 6822 at 820 MHz with the Green Bank Telescope for ∼15 and 5 hours respectively, and put a strong upper limit of 0.1 mJy on pulsars in either of the two galaxies. We also performed single pulse searches of both galaxies with no firm detections. (paper)

  4. Water saving in IC wafer washing process; IC wafer senjo deno sessui taisaku

    Energy Technology Data Exchange (ETDEWEB)

    Harada, H. [Mitsubishi Corp., Tokyo (Japan); Araki, M.; Nakazawa, T.

    1997-11-30

    This paper reports features of a wafer washing technology, a new IC wafer washing process, its pure water saving effect, and a `QC washing` which has pure water saving effect in the wafer washing. Wafer washing processes generally include the SC1 process (using ammonia + hydrogen peroxide aqueous solution) purposed for removing contamination due to ultrafine particles, the SC2 process (using hydrochloric acid + hydrogen peroxide aqueous solution) purposed for removing contamination due to heavy metals, the piranha washing process (using hot sulfuric acid + hydrogen peroxide aqueous solution) purposed for removing contamination due to organic matters, and the DHF (using dilute hydrofluoric acid) purposed for removing natural oxide films. Natural oxide films are now remained as surface protection films, by which surface contamination has been reduced remarkably. A high-temperature washing chemical circulating and filtering technology developed in Japan has brought about a reform in wafer washing processes having been used previously. Spin washing is used as a water saving measure, in which washing chemicals or pure water are sprayed onto one each of wafers which is spin-rotated, allowing washing and rinsing to be made with small amount of washing chemicals and pure water. The QC washing is a method to replace tank interior with pure was as quick as possible in order to increase the rinsing effect. 7 refs., 5 figs.

  5. Radon measurements at IC-09 well of Chingshui geothermal field (Taiwan): A case study

    International Nuclear Information System (INIS)

    Chen, Y.; Kuo, T.; Fan, K.; Liang, H.; Tsai, C.; Chiang, C.; Su, C.

    2011-01-01

    Radon concentration was monitored during the flow tests of well IC-09 at the Chingshui geothermal field. The radon concentration was found to increase from 54 ± 29 to 983 ± 65 Bq/m 3 as a step function of production time, or cumulative production. The observed radon behavior can be explained by a radial composite model with the carbonate scales deposited in the skin zone near the well. The radius of skin zone near well IC-09 can be estimated with radon data at about 20 m using a plug flow model. Monitoring natural radon during the well flow tests is a helpful tracer to diagnose the formation damage near the well.

  6. Immunogenicity and safety of different injection routes and schedules of IC41, a Hepatitis C virus (HCV) peptide vaccine.

    Science.gov (United States)

    Firbas, Christa; Boehm, Thomas; Buerger, Vera; Schuller, Elisabeth; Sabarth, Nicolas; Jilma, Bernd; Klade, Christoph S

    2010-03-11

    An effective vaccine would be a significant progress in the management of chronic HCV infections. This study was designed to examine whether different application schedules and injection routes may enhance the immunogenicity of the HCV peptide vaccine IC41. In this randomized trial 54 healthy subjects received either subcutaneous (s.c.) or intradermal (i.d.) vaccinations weekly (16 injections) or every other week (8 injections). One group additionally received imiquimod, an activator of the toll-like receptor (TLR) 7. The T cell epitope-specific immune response to IC41 was assessed using [(3)H]-thymidine CD4+ T cell proliferation, interferon-gamma (IFN-gamma) CD8+ and CD4+ ELIspot and HLA-A*0201 fluorescence-activated cell sorting (FACS) tetramer-binding assays. More than 60% of vaccinees responded in the CD4+ T cell proliferation assay in all groups. An HLA-A*0201 FACS tetramer-binding assay and IFN-gamma CD8+ ELIspot class I response of more than 70% was induced in four and three groups, respectively. IC41 induced significant immunological responses in all groups with responder rates of up to 100%. Interestingly, topical imiquimod was not able to enhance immunogenicity but was associated with a lower immune response. Local injection site reactions were mostly transient. Intradermal injections caused more pronounced reactions compared to s.c., especially erythema and edema. Compared to a previous study intensified dosing and/or i.d. injections enhanced the response rates to the vaccine IC41 in three assays measuring T cell function. Immunization with IC41 was generally safe in this study. These results justify testing IC41 in further clinical trials with HCV-infected individuals.

  7. Service Quality, Students' Satisfaction and Behavioural Intentions in STEM and IC Higher Education Institutions

    Directory of Open Access Journals (Sweden)

    Dunja Meštrović

    2017-03-01

    Full Text Available Service quality, students' satisfaction and their behavioural intentions are recognised as rather important aspects in higher education institution's strategy in a competitive higher education marketplace, which enable them to attract and retain students in science, technology, engineering and mathematics (STEM and information-communication (IC study areas. This research aimed to study the relationship between service quality, students' satisfaction and behavioural intentions of STEM and IC students of the University of Rijeka Departments. Partial least squares structural equation modelling using SmartPLS 3.0 software was performed on student survey data, confirming a direct, positive and significant relationship between higher education service quality and students' satisfaction and between students' satisfaction and their behavioural intentions. According to indirect effects analysis, perceived higher education service quality has an an indirect, positive and significant impact on students' behavioural intentions through students' satisfaction. The results indicate that higher education service quality is an imperative for higher education sector. Based on the findings of this study, useful to policy makers in the services industry in general and in higher education sector in particular, improvements can be planned all service quality dimensions as a key factor to attract, educate and retain STEM and IC students in Croatia.

  8. PREFACE: 4th International Conference on Mathematical Modeling in Physical Sciences (IC-MSquare2015)

    Science.gov (United States)

    Vlachos, Dimitrios; Vagenas, Elias C.

    2015-09-01

    The 4th International Conference on Mathematical Modeling in Physical Sciences (IC-MSQUARE) took place in Mykonos, Greece, from Friday 5th June to Monday 8th June 2015. The Conference was attended by more than 150 participants and hosted about 200 oral, poster, and virtual presentations. There were more than 600 pre-registered authors. The 4th IC-MSQUARE consisted of different and diverging workshops and thus covered various research fields where Mathematical Modeling is used, such as Theoretical/Mathematical Physics, Neutrino Physics, Non-Integrable Systems, Dynamical Systems, Computational Nanoscience, Biological Physics, Computational Biomechanics, Complex Networks, Stochastic Modeling, Fractional Statistics, DNA Dynamics, Macroeconomics etc. The scientific program was rather intense as after the Keynote and Invited Talks in the morning, three parallel oral and one poster session were running every day. However, according to all attendees, the program was excellent with a high quality of talks creating an innovative and productive scientific environment for all attendees. We would like to thank the Keynote Speaker and the Invited Speakers for their significant contribution to IC-MSQUARE. We also would like to thank the Members of the International Advisory and Scientific Committees as well as the Members of the Organizing Committee.

  9. 3D IC and RF SiPs advanced stacking and planar solutions for 5G mobility

    CERN Document Server

    Hwang, Lih-Tyng

    2017-01-01

    An interdisciplinary guide to enabling technologies for 3D ICs and 5G mobility, covering packaging, design to product life and reliability assessments * Features an interdisciplinary approach to the enabling technologies and hardware for 3D ICs and 5G mobility * Presents statistical treatments and examples with tools that are easily accessible, such as Microsoft's Excel and Minitab * Fundamental design topics such as electromagnetic design for logic and RF/passives centric circuits are explained in detail * Provides chapter-wise review questions and powerpoint slides as teaching tools

  10. Optical transceiver ICs based on 3D die-stacking of opto-electronic devices

    NARCIS (Netherlands)

    Duan, P.; Raz, O.; Smalbrugge, B.E.; Plassche, van de K.L.; Dorren, H.J.S.

    2013-01-01

    Wafer scale fabrication of the 3D stacked transceivers is discussed. Uniform open eye patterns at 10 Gb/s/channel of both 3D stacked transmitter and receiver ICs indicates that the interconnection technology is robust.

  11. 40 CFR 180.1154 - CryIA(c) and CryIC derived delta-endotoxins of Bacillus thuringiensis var. kurstaki encapsulated...

    Science.gov (United States)

    2010-07-01

    ... expression plasmid and cloning vector genetic constructs. 180.1154 Section 180.1154 Protection of Environment... RESIDUES IN FOOD Exemptions From Tolerances § 180.1154 CryIA(c) and CryIC derived delta-endotoxins of... plasmid and cloning vector genetic constructs. CryIA(c) and CryIC derived delta-endotoxins of Bacillus...

  12. Instantaneous flywheel torque of IC engine grey-box identification

    Science.gov (United States)

    Milašinović, A.; Knežević, D.; Milovanović, Z.; Škundrić, J.

    2018-01-01

    In this paper a mathematical model developed for the identification of excitation torque acting on the IC engine flywheel is presented. The excitation torque gained through internal combustion of the fuel in the IC engine is transmitted from the flywheel to the transmission. The torque is not constant but variable and is a function of the crank angle. The verification of the mathematical model was done on a 4-cylinder 4-stroke diesel engine for which the in-cylinder pressure was measured in one cylinder and the instantaneous angular speed of the crankshaft at its free end. The research was conducted on a hydraulic engine brake. Inertial forces of all rotational parts, from flywheel to the turbine wheel of the engine brake, are acting on the flywheel due to the nonuniform motion of the flywheel. It is known from the theory of turbomachinery that the torque on the hydraulic brake is a quadratic function of angular speed. Due to that and the variable angular speed of the turbine wheel of the engine brake, the torque during one engine cycle is also variable. The motivation for this research was the idea (intention) to determine the instantaneous torque acting on the flywheel as a function of the crank angle with a mathematical model without any measuring and based on this to determine the quality of work of specific cylinders of the multi-cylinder engine. The crankshaft was considered elastic and also its torsional vibrations were taken into account.

  13. Model-based setting of inspiratory pressure and respiratory rate in pressure-controlled ventilation

    International Nuclear Information System (INIS)

    Schranz, C; Möller, K; Becher, T; Schädler, D; Weiler, N

    2014-01-01

    Mechanical ventilation carries the risk of ventilator-induced-lung-injury (VILI). To minimize the risk of VILI, ventilator settings should be adapted to the individual patient properties. Mathematical models of respiratory mechanics are able to capture the individual physiological condition and can be used to derive personalized ventilator settings. This paper presents model-based calculations of inspiration pressure (p I ), inspiration and expiration time (t I , t E ) in pressure-controlled ventilation (PCV) and a retrospective evaluation of its results in a group of mechanically ventilated patients. Incorporating the identified first order model of respiratory mechanics in the basic equation of alveolar ventilation yielded a nonlinear relation between ventilation parameters during PCV. Given this patient-specific relation, optimized settings in terms of minimal p I and adequate t E can be obtained. We then retrospectively analyzed data from 16 ICU patients with mixed pathologies, whose ventilation had been previously optimized by ICU physicians with the goal of minimization of inspiration pressure, and compared the algorithm's ‘optimized’ settings to the settings that had been chosen by the physicians. The presented algorithm visualizes the patient-specific relations between inspiration pressure and inspiration time. The algorithm's calculated results highly correlate to the physician's ventilation settings with r = 0.975 for the inspiration pressure, and r = 0.902 for the inspiration time. The nonlinear patient-specific relations of ventilation parameters become transparent and support the determination of individualized ventilator settings according to therapeutic goals. Thus, the algorithm is feasible for a variety of ventilated ICU patients and has the potential of improving lung-protective ventilation by minimizing inspiratory pressures and by helping to avoid the build-up of clinically significant intrinsic positive end

  14. Model-based setting of inspiratory pressure and respiratory rate in pressure-controlled ventilation.

    Science.gov (United States)

    Schranz, C; Becher, T; Schädler, D; Weiler, N; Möller, K

    2014-03-01

    Mechanical ventilation carries the risk of ventilator-induced-lung-injury (VILI). To minimize the risk of VILI, ventilator settings should be adapted to the individual patient properties. Mathematical models of respiratory mechanics are able to capture the individual physiological condition and can be used to derive personalized ventilator settings. This paper presents model-based calculations of inspiration pressure (pI), inspiration and expiration time (tI, tE) in pressure-controlled ventilation (PCV) and a retrospective evaluation of its results in a group of mechanically ventilated patients. Incorporating the identified first order model of respiratory mechanics in the basic equation of alveolar ventilation yielded a nonlinear relation between ventilation parameters during PCV. Given this patient-specific relation, optimized settings in terms of minimal pI and adequate tE can be obtained. We then retrospectively analyzed data from 16 ICU patients with mixed pathologies, whose ventilation had been previously optimized by ICU physicians with the goal of minimization of inspiration pressure, and compared the algorithm's 'optimized' settings to the settings that had been chosen by the physicians. The presented algorithm visualizes the patient-specific relations between inspiration pressure and inspiration time. The algorithm's calculated results highly correlate to the physician's ventilation settings with r = 0.975 for the inspiration pressure, and r = 0.902 for the inspiration time. The nonlinear patient-specific relations of ventilation parameters become transparent and support the determination of individualized ventilator settings according to therapeutic goals. Thus, the algorithm is feasible for a variety of ventilated ICU patients and has the potential of improving lung-protective ventilation by minimizing inspiratory pressures and by helping to avoid the build-up of clinically significant intrinsic positive end-expiratory pressure.

  15. LABA/LAMA combinations versus LAMA monotherapy or LABA/ICS in COPD: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Rodrigo GJ

    2017-03-01

    Full Text Available Gustavo J Rodrigo,1 David Price,2,3 Antonio Anzueto,4,5 Dave Singh,6 Pablo Altman,7 Giovanni Bader,8 Francesco Patalano,8 Robert Fogel,7 Konstantinos Kostikas8 1Departamento de Emergencia, Hospital Central de las Fuerzas Armadas, Montevideo, Uruguay; 2Academic Primary Care, Division of Applied Health Sciences, University of Aberdeen, Aberdeen, Scotland, UK; 3Observational and Pragmatic Research Institute, Singapore; 4University of Texas Health Science Center, 5South Texas Veterans Health Care System, San Antonio, TX, USA; 6Medicines Evaluation Unit, National Institute for Health Research Respiratory and Allergy Clinical Research Facility, University Hospital of South Manchester NHS Foundation Trust, University of Manchester, Manchester, England, UK; 7Novartis Pharmaceuticals Corporation, East Hanover, NJ, USA; 8Novartis Pharma AG, Basel, Switzerland Background: Randomized controlled trials (RCTs indicate that long-acting bronchodilator combinations, such as β2-agonist (LABA/muscarinic antagonist (LAMA, have favorable efficacy compared with commonly used COPD treatments. The objective of this analysis was to compare the efficacy and safety of LABA/LAMA with LAMA or LABA/inhaled corticosteroid (ICS in adults with stable moderate-to-very-severe COPD. Methods: This systematic review and meta-analysis (PubMed/MEDLINE, Embase, Cochrane Library and clinical trial/manufacturer databases included RCTs comparing ≥12 weeks’ LABA/LAMA treatment with LAMA and/or LABA/ICS (approved doses only. Eligible studies were independently selected by two authors using predefined data fields; the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were followed. Results: Eighteen studies (23 trials were eligible (N=20,185. LABA/LAMA significantly improved trough forced expiratory volume in 1 second (FEV1 from baseline to week 12 versus both LAMA and LABA/ICS (0.07 L and 0.08 L, P<0.0001, with patients more likely to achieve clinically

  16. Near-infrared photometric study of open star cluster IC 1805

    International Nuclear Information System (INIS)

    Sagar, R.; Yu, Q.Z.

    1990-01-01

    The JHK magnitudes of 29 stars in the region of open star cluster IC 1805 were measured. These, and the existing infrared and optical observations, indicate a normal interstellar extinction law in the direction of the cluster. Further, most of the early-type stars have near-infrared fluxes as expected from their spectral types. Patchy distribution of ionized gas and dust appears to be the cause of nonuniform extinction across the cluster face. 36 refs

  17. An Investigation of the Antioxidant Capacity in Extracts from Moringa oleifera Plants Grown in Jamaica.

    Science.gov (United States)

    Wright, Racquel J; Lee, Ken S; Hyacinth, Hyacinth I; Hibbert, Jacqueline M; Reid, Marvin E; Wheatley, Andrew O; Asemota, Helen N

    2017-10-23

    Moringa oleifera trees grow well in Jamaica and their parts are popularly used locally for various purposes and ailments. Antioxidant activities in Moringa oleifera samples from different parts of the world have different ranges. This study was initiated to determine the antioxidant activity of Moringa oleifera grown in Jamaica. Dried and milled Moringa oleifera leaves were extracted with ethanol/water (4:1) followed by a series of liquid-liquid extractions. The antioxidant capacities of all fractions were tested using a 2,2-diphenyl-1-picrylhydrazyl (DPPH) assay. IC 50 values (the amount of antioxidant needed to reduce 50% of DPPH) were then determined and values for the extracts ranged from 177 to 4458 μg/mL. Extracts prepared using polar solvents had significantly higher antioxidant capacities than others and may have clinical applications in any disease characterized by a chronic state of oxidative stress, such as sickle cell anemia. Further work will involve the assessment of these extracts in a sickle cell model of oxidative stress.

  18. Nanometer CMOS ICs from basics to ASICs

    CERN Document Server

    J M Veendrick, Harry

    2017-01-01

    This textbook provides a comprehensive, fully-updated introduction to the essentials of nanometer CMOS integrated circuits. It includes aspects of scaling to even beyond 12nm CMOS technologies and designs. It clearly describes the fundamental CMOS operating principles and presents substantial insight into the various aspects of design implementation and application. Coverage includes all associated disciplines of nanometer CMOS ICs, including physics, lithography, technology, design, memories, VLSI, power consumption, variability, reliability and signal integrity, testing, yield, failure analysis, packaging, scaling trends and road blocks. The text is based upon in-house Philips, NXP Semiconductors, Applied Materials, ASML, IMEC, ST-Ericsson, TSMC, etc., courseware, which, to date, has been completed by more than 4500 engineers working in a large variety of related disciplines: architecture, design, test, fabrication process, packaging, failure analysis and software.

  19. The MusIC method: a fast and quasi-optimal solution to the muscle forces estimation problem.

    Science.gov (United States)

    Muller, A; Pontonnier, C; Dumont, G

    2018-02-01

    The present paper aims at presenting a fast and quasi-optimal method of muscle forces estimation: the MusIC method. It consists in interpolating a first estimation in a database generated offline thanks to a classical optimization problem, and then correcting it to respect the motion dynamics. Three different cost functions - two polynomial criteria and a min/max criterion - were tested on a planar musculoskeletal model. The MusIC method provides a computation frequency approximately 10 times higher compared to a classical optimization problem with a relative mean error of 4% on cost function evaluation.

  20. The Toby Jug nebula (IC 2220): a bipolar and biconical nebula

    International Nuclear Information System (INIS)

    Perkins, H.G.; King, D.J.; Scarrott, S.M.

    1981-01-01

    An optical linear polarization map of IC 2220, the nebula surrounding the cool red giant HD 65750, is presented. The nebula appears to be bipolar and biconical in structure. The mass of the nebula is estimated to be 0.01 solar mass and is consistent with the nebula being formed from the current mass loss stage of the central star. (author)

  1. VARIABILITY OF FORCED OSCILLATION (SIEMENS SIREGNOST FD-5) MEASUREMENTS OF TOTAL RESPIRATORY RESISTANCE IN PATIENTS AND HEALTHY-SUBJECTS

    NARCIS (Netherlands)

    GIMENO, F; VANDERWEELE, LT; KOETER, GH; DEMONCHY, JGR; VANALTENA, R

    The reproducibility of total respiratory resistance (R(rs)) measured with a simplified forced oscillatory method (Siemens Siregnost FD 5) was measured and compared with that of slow inspiratory vital capacity (IVC) and forced expiratory volume in one second (FEV1). The former technique has the

  2. Noninvasive ventilation reduces energy expenditure in amyotrophic lateral sclerosis.

    Science.gov (United States)

    Georges, Marjolaine; Morélot-Panzini, Capucine; Similowski, Thomas; Gonzalez-Bermejo, Jesus

    2014-02-07

    Amyotrophic lateral sclerosis (ALS) leads to chronic respiratory failure. Diaphragmatic dysfunction, a major driver of dyspnea and mortality, is associated with a shift of the burden of ventilation to extradiaphragmatic inspiratory muscles, including neck muscles. Besides, energy expenditure is often abnormally high in ALS, and this is associated with a negative prognostic value. We hypothesized that noninvasive ventilation (NIV) would relieve inspiratory neck muscles and reduce resting energy expenditure (REE). Using indirect calorimetry, we measured REE during spontaneous breathing (REESB) and NIV (REENIV) in 16 ALS patients with diaphragmatic dysfunction, during the first 3 months of NIV. Measured values were compared with predicted REE (REEpred)(Harris-Benedict equation). NIV abolished inspiratory neck muscle activity. Even though our patients were not hypermetabolic, on the contrary, with a REESB that was lower than REEpred (average 11%), NIV did reduce energy expenditure. Indeed, median REENIV, in this population with a mean body mass index of 21.4 kg.m-2, was 1149 kcal/24 h [interquartile 970-1309], lower than REESB (1197 kcal/24 h, 1054-1402; mean difference 7%; p = 0.03, Wilcoxon). REESB and REENIV were correlated with forced vital capacity and maximal inspiratory pressure. NIV can reduce energy expenditure in ALS patients probably by alleviating the ventilatory burden imposed on inspiratory neck muscles to compensate diaphragm weakness. It remains to be elucidated whether or not, in which population, and to what extent, NIV can be beneficial in ALS through the corresponding reduction in energy expenditure.

  3. Nuclear Factor I-C promotes proliferation and differentiation of apical papilla-derived human stem cells in vitro

    International Nuclear Information System (INIS)

    Zhang, Jing; Wang, Zhihua; Jiang, Yong; Niu, Zhongying; Fu, Lei; Luo, Zhirong; Cooper, Paul R.; Smith, Anthony J.; He, Wenxi

    2015-01-01

    The transcription factor Nuclear Factor I-C (NFIC) has been implicated in the regulation of tooth root development, where it may be anticipated to impact on the behavior of stem cells from the apical papilla (SCAPs) and root odontoblast activity. We hypothesized that NFIC may provide an important target for promoting dentin/root regeneration. In the present study, the effects of NFIC on the proliferation and differentiation of SCAPs were investigated. Over-expression of NFIC increased cell proliferation, mineralization nodule formation and alkaline phosphatase (ALP) activity in SCAPs. Furthermore, NFIC up-regulated the mRNA levels of odontogenic-related markers, ALP, osteocalcin and collagen type I as well as dentin sialoprotein protein levels. In contrast, knockdown of NFIC by si-RNA inhibited the mineralization capacity of SCAPs and down-regulated the expression of odontogenic-related markers. In conclusion, the results indicated that upregulation of NFIC activity in SCAPs may promote osteo/odontoblastic differentiation of SCAPs. - Highlights: • NFIC promotes the proliferation of SCAPs in vitro. • NFIC promotes osteo/odontogenic differentiation of SCAPs in vitro. • Knockdown of NFIC inhibits odontogenic differentiation in SCAPs

  4. Nuclear Factor I-C promotes proliferation and differentiation of apical papilla-derived human stem cells in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jing [State Key Laboratory of Military Stomatology, Department of Operative Dentistry & Endodontics, School of Stomatology, The Fourth Military Medical University, Xi' an (China); Stomatologic Hospital & College, Anhui Medical University, Key Lab of Oral Diseases Research of Anhui Province, Hefei (China); Wang, Zhihua; Jiang, Yong [State Key Laboratory of Military Stomatology, Department of Operative Dentistry & Endodontics, School of Stomatology, The Fourth Military Medical University, Xi' an (China); Niu, Zhongying [Treatment center of oral diseases, The 306th Hospital of People' s Liberation Army, Beijing (China); Fu, Lei; Luo, Zhirong [State Key Laboratory of Military Stomatology, Department of Operative Dentistry & Endodontics, School of Stomatology, The Fourth Military Medical University, Xi' an (China); Cooper, Paul R.; Smith, Anthony J. [Oral Biology, School of Dentistry, University of Birmingham, B4 6NN (United Kingdom); He, Wenxi, E-mail: hewenxi@fmmu.edu.cn [State Key Laboratory of Military Stomatology, Department of Operative Dentistry & Endodontics, School of Stomatology, The Fourth Military Medical University, Xi' an (China)

    2015-03-15

    The transcription factor Nuclear Factor I-C (NFIC) has been implicated in the regulation of tooth root development, where it may be anticipated to impact on the behavior of stem cells from the apical papilla (SCAPs) and root odontoblast activity. We hypothesized that NFIC may provide an important target for promoting dentin/root regeneration. In the present study, the effects of NFIC on the proliferation and differentiation of SCAPs were investigated. Over-expression of NFIC increased cell proliferation, mineralization nodule formation and alkaline phosphatase (ALP) activity in SCAPs. Furthermore, NFIC up-regulated the mRNA levels of odontogenic-related markers, ALP, osteocalcin and collagen type I as well as dentin sialoprotein protein levels. In contrast, knockdown of NFIC by si-RNA inhibited the mineralization capacity of SCAPs and down-regulated the expression of odontogenic-related markers. In conclusion, the results indicated that upregulation of NFIC activity in SCAPs may promote osteo/odontoblastic differentiation of SCAPs. - Highlights: • NFIC promotes the proliferation of SCAPs in vitro. • NFIC promotes osteo/odontogenic differentiation of SCAPs in vitro. • Knockdown of NFIC inhibits odontogenic differentiation in SCAPs.

  5. Influence of the doping additives on heat stability and heat transfer of nickel coverings of cases IC

    Directory of Open Access Journals (Sweden)

    Novosyadly S. P.

    2008-04-01

    Full Text Available With the help of modern diagnostic microanalysis tools, the regularities are established for variation of electrophysical parameters of Ni-B galvanic coating of IC packages in the process of ultrasonic welding of internal Al leads and package seal. The optimal composition of the electrolyte which provides heat resistance increase of IC packages with alloyed Ni coating is selected. This, combined with the local gilding, enables mounting of crystals through a eutectic Si-Au sublayer.

  6. Congenital disorder of glycosylation Ic due to a de novo deletion and an hALG-6 mutation.

    Science.gov (United States)

    Eklund, Erik A; Sun, Liangwu; Yang, Samuel P; Pasion, Romela M; Thorland, Erik C; Freeze, Hudson H

    2006-01-20

    We describe a new cause of congenital disorder of glycosylation-Ic (CDG-Ic) in a young girl with a rather mild CDG phenotype. Her cells accumulated lipid-linked oligosaccharides lacking three glucose residues, and sequencing of the ALG6 gene showed what initially appeared to be a homozygous novel point mutation (338G>A). However, haplotype analysis showed that the patient does not carry any paternal DNA markers extending 33kb in the telomeric direction from the ALG6 region, and microsatellite analysis extended the abnormal region to at least 2.5Mb. We used high-resolution karyotyping to confirm a deletion (10-12Mb) [del(1)(p31.2p32.3)] and found no structural abnormalities in the father, suggesting a de novo event. Our findings extend the causes of CDG to larger DNA deletions and identify the first Japanese CDG-Ic mutation.

  7. The H I chronicles of little things BCDs II: The origin of IC 10's H I structure

    Energy Technology Data Exchange (ETDEWEB)

    Ashley, Trisha; Simpson, Caroline E.; Pokhrel, Nau Raj [Department of Physics, Florida International University, 11200 SW 8th Street, CP 204, Miami, FL 33199 (United States); Elmegreen, Bruce G. [IBM T. J. Watson Research Center, PO Box 218, Yorktown Heights, New York 10598 (United States); Johnson, Megan [CSIRO Astronomy and Space Science P.O. Box 76, Epping, NSW 1710 Australia (Australia); Nidever, David L., E-mail: trisha.l.ashley@nasa.gov, E-mail: simpsonc@fiu.edu, E-mail: npokh001@fiu.edu, E-mail: bge@us.ibm.com, E-mail: megan.johnson@csiro.au, E-mail: dnidever@umich.edu [Department of Astronomy, University of Michigan Ann Arbor, MI, 48109 (United States)

    2014-12-01

    In this paper we analyze Very Large Array (VLA) telescope and Green Bank Telescope (GBT) atomic hydrogen (H I) data for the LITTLE THINGS (Local Irregulars That Trace Luminosity Extremes, The H I Nearby Galaxy Survey; https://science.nrao.edu/science/surveys/littlethings) blue compact dwarf galaxy IC 10. The VLA data allow us to study the detailed H I kinematics and morphology of IC 10 at high resolution while the GBT data allow us to search the surrounding area at high sensitivity for tenuous H I. IC 10's H I appears highly disturbed in both the VLA and GBT H I maps with a kinematically distinct northern H I extension, a kinematically distinct southern plume, and several spurs in the VLA data that do not follow the general kinematics of the main disk. We discuss three possible origins of its H I structure and kinematics in detail: a current interaction with a nearby companion, an advanced merger, and accretion of intergalactic medium. We find that IC 10 is most likely an advanced merger or a galaxy undergoing accretion.

  8. The H I chronicles of little things BCDs II: The origin of IC 10's H I structure

    International Nuclear Information System (INIS)

    Ashley, Trisha; Simpson, Caroline E.; Pokhrel, Nau Raj; Elmegreen, Bruce G.; Johnson, Megan; Nidever, David L.

    2014-01-01

    In this paper we analyze Very Large Array (VLA) telescope and Green Bank Telescope (GBT) atomic hydrogen (H I) data for the LITTLE THINGS (Local Irregulars That Trace Luminosity Extremes, The H I Nearby Galaxy Survey; https://science.nrao.edu/science/surveys/littlethings) blue compact dwarf galaxy IC 10. The VLA data allow us to study the detailed H I kinematics and morphology of IC 10 at high resolution while the GBT data allow us to search the surrounding area at high sensitivity for tenuous H I. IC 10's H I appears highly disturbed in both the VLA and GBT H I maps with a kinematically distinct northern H I extension, a kinematically distinct southern plume, and several spurs in the VLA data that do not follow the general kinematics of the main disk. We discuss three possible origins of its H I structure and kinematics in detail: a current interaction with a nearby companion, an advanced merger, and accretion of intergalactic medium. We find that IC 10 is most likely an advanced merger or a galaxy undergoing accretion.

  9. VizieR Online Data Catalog: Absorption velocities for 21 super-luminous SNe Ic (Liu+, 2017)

    Science.gov (United States)

    Liu, Y.-Q.; Modjaz, M.; Bianco, F. B.

    2018-04-01

    We have collected the spectra of all available super-luminous supernovae (SLSNe) Ic that have a date of maximum light published before April of 2016. These SLSNe Ic were mainly discovered and observed by the All-Sky Automated Survey for Supernovae (ASAS-SN), the Catalina Real-Time Transient Survey, the Dark Energy Survey (DES), the Hubble Space Telescope Cluster Supernova Survey, the Pan-STARRS1 Medium Deep Survey (PS1), the Public ESO Spectroscopic Survey of Transient Objects (PESSTO), the Intermediate Palomar Transient Factory (iPTF) as well as the Palomar Transient Factory (PTF), and the Supernova Legacy Survey (SNLS). See table 1. (2 data files).

  10. INTEGRAL FIELD SPECTROSCOPY OF SUPERNOVA EXPLOSION SITES: CONSTRAINING THE MASS AND METALLICITY OF THE PROGENITORS. I. TYPE Ib AND Ic SUPERNOVAE

    Energy Technology Data Exchange (ETDEWEB)

    Kuncarayakti, Hanindyo; Maeda, Keiichi [Kavli Institute for the Physics and Mathematics of the Universe (WPI), Todai Institutes for Advanced Study, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8583 (Japan); Doi, Mamoru; Morokuma, Tomoki; Hashiba, Yasuhito [Institute of Astronomy, Graduate School of Science, The University of Tokyo, 2-21-1 Osawa, Mitaka, Tokyo 181-0015 (Japan); Aldering, Greg [Physics Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Arimoto, Nobuo [National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo 181-0015 (Japan); Pereira, Rui [CNRS/IN2P3, Institut de Physique Nucleaire de Lyon, 4 Rue Enrico Fermi, F-69622 Villeurbanne Cedex (France); Usuda, Tomonori, E-mail: hanindyo.kuncarayakti@ipmu.jp [Subaru Telescope, National Astronomical Observatory of Japan, 650 North A' ohoku Place, Hilo, HI 96720 (United States)

    2013-08-01

    Integral field spectroscopy of 11 Type Ib/Ic supernova (SN Ib/Ic) explosion sites in nearby galaxies has been obtained using UH88/SNIFS and Gemini-N/GMOS. The use of integral field spectroscopy enables us to obtain both spatial and spectral information about the explosion site, enabling the identification of the parent stellar population of the SN progenitor star. The spectrum of the parent population provides metallicity determination via strong-line method and age estimation obtained via comparison with simple stellar population models. We adopt this information as the metallicity and age of the SN progenitor, under the assumption that it was coeval with the parent stellar population. The age of the star corresponds to its lifetime, which in turn gives the estimate of its initial mass. With this method we were able to determine both the metallicity and initial (zero-age main sequence) mass of the progenitor stars of SNe Ib and Ic. We found that on average SN Ic explosion sites are more metal-rich and younger than SN Ib sites. The initial mass of the progenitors derived from parent stellar population age suggests that SN Ic has more massive progenitors than SN Ib. In addition, we also found indication that some of our SN progenitors are less massive than {approx}25 M{sub Sun }, indicating that they may have been stars in a close binary system that have lost their outer envelope via binary interactions to produce SNe Ib/Ic, instead of single Wolf-Rayet stars. These findings support the current suggestions that both binary and single progenitor channels are in effect in producing SNe Ib/Ic. This work also demonstrates the power of integral field spectroscopy in investigating SN environments and active star-forming regions.

  11. 2nd International Conference on Rheology and Modeling of Materials (IC-RMM2)

    International Nuclear Information System (INIS)

    2017-01-01

    Understanding the rheological properties of materials and their rheological behaviors during their manufacturing processes and in their applications in many cases can help to increase the efficiency and competitiveness not only of the finished goods and products but the organizations and societies also. The more scientific supported and prepared organizations develop more competitive products with better thermal, mechanical, physical, chemical and biological properties and the leading companies apply more competitive equipment and technology processes. The aims of the 2 nd International Conference on Rheology and Modeling of Materials (ic-rmm2) and the parallel organized symposiums of the 1 st International Symposium on Powder Injection Molding (is-pim1) and the 1 st International Symposium on Rheology and Fracture of Solids (is-rfs1) are the followings: Promote new methods and results of scientific research in the fields of modeling and measurements of rheological properties and behavior of materials under processing and applications; Change information between the theoretical and applied sciences as well as technical and technological implantations. Promote the communication and collaboration between the scientists, researchers and engineers of different disciplines, different nations, countries and continents. The international conference ic-rmm2 and symposiums of is-pim1 and is-rfs1 provide a platform among the leading international scientists, researchers, PhD students and engineers for discussing recent achievements in measurement, modeling and application of rheology in materials technology and materials science of liquids, melts, solids, crystals and amorphous structures. Among thr major fields of interest are the influence of materials structures, mechanical stresses, temperatures, deformation speeds and shear rates on rheological and physical properties, phase transformation of foams, foods, polymers, plastics and other competitive materials like ceramics

  12. 2nd International Conference on Rheology and Modeling of Materials (IC-RMM2)

    Science.gov (United States)

    2017-01-01

    Understanding the rheological properties of materials and their rheological behaviors during their manufacturing processes and in their applications in many cases can help to increase the efficiency and competitiveness not only of the finished goods and products but the organizations and societies also. The more scientific supported and prepared organizations develop more competitive products with better thermal, mechanical, physical, chemical and biological properties and the leading companies apply more competitive equipment and technology processes. The aims of the 2nd International Conference on Rheology and Modeling of Materials (ic-rmm2) and the parallel organized symposiums of the 1st International Symposium on Powder Injection Molding (is-pim1) and the 1st International Symposium on Rheology and Fracture of Solids (is-rfs1) are the followings: Promote new methods and results of scientific research in the fields of modeling and measurements of rheological properties and behavior of materials under processing and applications; Change information between the theoretical and applied sciences as well as technical and technological implantations. Promote the communication and collaboration between the scientists, researchers and engineers of different disciplines, different nations, countries and continents. The international conference ic-rmm2 and symposiums of is-pim1 and is-rfs1 provide a platform among the leading international scientists, researchers, PhD students and engineers for discussing recent achievements in measurement, modeling and application of rheology in materials technology and materials science of liquids, melts, solids, crystals and amorphous structures. Among thr major fields of interest are the influence of materials structures, mechanical stresses, temperatures, deformation speeds and shear rates on rheological and physical properties, phase transformation of foams, foods, polymers, plastics and other competitive materials like ceramics

  13. An International Urogynecological Association (IUGA)/International Continence Society (ICS) joint report on the terminology for female anorectal dysfunction

    OpenAIRE

    Sultan, A. H.; Monga, A.; Lee, J.; Emmanuel, A.; Norton, C.; Santoro, G.; Hull, T.; Berghmans, B.; Brody, S.; Haylen, B. T.

    2017-01-01

    INTRODUCTION AND HYPOTHESIS: The terminology for anorectal dysfunction in women has long been in need of a specific clinically-based Consensus Report. METHODS: This Report combines the input of members of the Standardization and Terminology Committees of two International Organizations, the International Urogynecological Association (IUGA) and the International Continence Society (ICS), assisted on Committee by experts in their fields to form a Joint IUGA/ICS Working Group on Female Anorectal...

  14. An International Urogynecological Association (IUGA)/International Continence Society (ICS) Joint Report on the Terminology for Female Anorectal Dysfunction

    OpenAIRE

    Sultan, A. H.; Monga, A.; Lee, J.; Emmanuel, A.; Norton, C.; Santoro, G.; Hull, T.; Berghmans, B.; Brody, S.; Haylen, B. T.

    2017-01-01

    INTRODUCTION: The terminology for anorectal dysfunction in women has long been in need of a specific clinically-based Consensus Report. METHODS: This Report combines the input of members of the Standardization and Terminology Committees of two International Organizations, the International Urogynecological Association (IUGA) and the International Continence Society (ICS), assisted on Committee by experts in their fields to form a Joint IUGA/ICS Working Group on Female Anorectal Termi...

  15. ic-cmtp3: 3rd International Conference on Competitive Materials and Technology Processes

    Science.gov (United States)

    2016-04-01

    Competitiveness is one of the most important factors in our lives and it plays a key role in the efficiency both of organizations and societies. The more scientifically advanced and prepared organizations develop more competitive materials with better physical, chemical, and biological properties, and the leading companies apply more competitive equipment and technological processes. The aims of the 3rd International Conference on Competitive Materials and Technology Processes (ic-cmtp3), and the 1st International Symposium on Innovative Carbons and Carbon Based Materials (is-icbm1) and the 1st International Symposium on Innovative Construction Materials (is-icm1) organized alongside are the following: —Promote new methods and results of scientific research in the fields of material, biological, environmental and technological sciences; —Exchange information between the theoretical and applied sciences as well as technical and technological implementations; —Promote communication and collaboration between the scientists, researchers and engineers of different nations, countries and continents. Among the major fields of interest are advanced and innovative materials with competitive characteristics, including mechanical, physical, chemical, biological, medical and thermal, properties and extreme dynamic strength. Their crystalline, nano - and micro-structures, phase transformations as well as details of their technological processes, tests and measurements are also in the focus of the ic-cmtp3 conference and the is-scbm1 and is-icm1 symposia. Multidisciplinary applications of material science and the technological problems encountered in sectors like ceramics, glasses, thin films, aerospace, automotive and marine industries, electronics, energy, construction materials, medicine, biosciences and environmental sciences are of particular interest. In accordance with the program of the ic-cmtp3 conference and is-icbm1 and is-icm1 symposia we have received more

  16. Nasal and skin delivery of IC31(®)-adjuvanted recombinant HSV-2 gD protein confers protection against genital herpes.

    Science.gov (United States)

    Wizel, Benjamin; Persson, Josefine; Thörn, Karolina; Nagy, Eszter; Harandi, Ali M

    2012-06-19

    Genital herpes caused by herpes simplex virus type 2 (HSV-2) remains the leading cause of genital ulcers worldwide. Given the disappointing results of the recent genital herpes vaccine trials in humans, development of novel vaccine strategies capable of eliciting protective mucosal and systemic immune responses to HSV-2 is urgently required. Here we tested the ability of the adjuvant IC31(®) in combination with HSV-2 glycoprotein D (gD) used through intranasal (i.n.), intradermal (i.d.), or subcutaneous (s.c.) immunization routes for induction of protective immunity against genital herpes infection in C57BL/6 mice. Immunization with gD plus IC31(®) through all three routes of immunization developed elevated gD-specific serum antibody responses with HSV-2 neutralizing activity. Whereas the skin routes promoted the induction of a mixed IgG2c/IgG1 isotype profile, the i.n. route only elicited IgG1 antibodies. All immunization routes were able to induce gD-specific IgG antibody responses in the vaginas of mice immunized with IC31(®)-adjuvanted gD. Although specific lymphoproliferative responses were observed in splenocytes from mice of most groups vaccinated with IC31(®)-adjuvanted gD, only i.d. immunization resulted in a significant splenic IFN-γ response. Further, immunization with gD plus IC31(®) conferred 80-100% protection against an otherwise lethal vaginal HSV-2 challenge with amelioration of viral replication and disease severity in the vagina. These results warrant further exploration of IC31(®) for induction of protective immunity against genital herpes and other sexually transmitted infections. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Changing adherence-related beliefs about ICS maintenance treatment for asthma: feasibility study of an intervention delivered by asthma nurse specialists.

    Science.gov (United States)

    Chapman, Sarah C E; Barnes, Neil; Barnes, Mari; Wilkinson, Andrea; Hartley, John; Piddock, Cher; Weinman, John; Horne, Rob

    2015-06-05

    The Necessity-Concerns Framework (NCF) posits that non-adherence to inhaled corticosteroids (ICS) in asthma is influenced by doubts about the necessity for ICS and concerns about their potential adverse effects. This feasibility study examined whether these beliefs could be changed by briefing asthma nurse specialists on ways of addressing necessity beliefs and concerns within consultations. Pre-post intervention study. Secondary care. Patients with a diagnosis of moderate to severe asthma who were prescribed daily ICS were recruited to either a hospital care group (n=79; 71.0% female) or intervention group (n=57; 66.7% female). Asthma nurse specialists attended a 1.5-day NCF briefing. Beliefs about ICS (primary outcome) and self-reported adherence were measured preconsultation and 1 month postconsultation. Participants also rated their satisfaction with their consultations immediately after the consultation. Consultation recordings were coded to assess intervention delivery. After the NCF briefing, nurse specialists elicited and addressed beliefs about medicine more frequently. The frequency of using the NCF remained low, for example, open questions eliciting adherence were used in 0/59 hospital care versus 14/49 (28.6%) intervention consultations. Doubts about personal necessity for, and concerns about, ICS were reduced at 1 month postbriefing (pchanged nurse consultations, but not sufficiently enough to fully address non-adherence or adherence-related ICS beliefs (necessity and concerns). More effective techniques are needed to support nurse specialists and other practitioners to apply the intervention in hospital asthma review consultations. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Extracorporeal Membrane Oxygenation (ECMO) for Severe Toxicological Exposures: Review of the Toxicology Investigators Consortium (ToxIC).

    Science.gov (United States)

    Wang, G S; Levitan, R; Wiegand, T J; Lowry, J; Schult, R F; Yin, S

    2016-03-01

    Although there have been many developments related to specific strategies for treating patients after poisoning exposures, the mainstay of therapy remains symptomatic and supportive care. One of the most aggressive supportive modalities is extracorporeal membrane oxygenation (ECMO). Our goal was to describe the use of ECMO for toxicological exposures reported to the American College of Medical Toxicology (ACMT) Toxicology Investigators Consortium (ToxIC). We performed a retrospective review of the ACMT ToxIC Registry from January 1, 2010 to December 31, 2013. Inclusion criteria included patients aged 0 to 89 years, evaluated between January 2010 through December 2013, and received ECMO for toxicological exposure. There were 26,271 exposures (60 % female) reported to the ToxIC Registry, 10 (0.0004 %) received ECMO: 4 pediatric (18 years). Time of initiation of ECMO ranged from 4 h to 4 days, with duration from 15 h to 12 days. Exposures included carbon monoxide/smoke inhalation (2), bitter almonds, methanol, and several medications including antihistamines (2), antipsychotic/antidepressant (2), cardiovascular drugs (2), analgesics (2), sedative/hypnotics (2), and antidiabetics (2). Four ECMO patients received cardiopulmonary resuscitation (CPR) during their hospital course, and the overall survival rate was 80 %. ECMO was rarely used for poisoning exposures in the ACMT ToxIC Registry. ECMO was utilized for a variety of ages and for pharmaceutical and non-pharmaceutical exposures. In most cases, ECMO was administered prior to cardiovascular failure, and survival rate was high. If available, ECMO may be a valid treatment modality.

  19. Na-ion capacitor using sodium pre-doped hard carbon and activated carbon

    International Nuclear Information System (INIS)

    Kuratani, Kentaro; Yao, Masaru; Senoh, Hiroshi; Takeichi, Nobuhiko; Sakai, Tetsuo; Kiyobayashi, Tetsu

    2012-01-01

    We assembled a sodium-ion capacitor (Na-IC) by combining sodium pre-doped hard carbon (HC) as the negative- and activated carbon (AC) as the positive-electrode. The electrochemical properties were compared with two lithium-ion capacitors (Li-ICs) in which the negative electrodes were prepared with Li pre-doped HC and mesocarbon microbeads (MCMB). The positive and negative electrodes were prepared using the established doctor blade method. The negative electrodes were galvanostatically pre-doped with Na or Li to 80% of the full capacity of carbons. The potential of the negative electrodes after pre-doping was around 0.0 V vs. Na/Na + or Li/Li + , which resulted in the higher output potential difference of the Na-IC and Li-ICs than that of the conventional electrochemical double-layer capacitors (EDLCs) because AC positive electrode works in the same principle both in the ion capacitors and in the EDLC. The state-of-charge of the negative electrode varied 80 ± 10% during the electrochemical charging and discharging. The capacity of the cell was evaluated using galvanostatic charge–discharge measurement. At the discharge current density of 10 mA cm −2 , the Na-IC maintained 70% of the capacity that obtained at the current density of 0.5 mA cm −2 , which was comparable to the Li-ICs. At 50 mA cm −2 , the capacities of the Li-IC(MCMB) and the Na-IC dropped to 20% whereas the Li-IC(HC) retained 30% of the capacity observed at 0.5 mA cm −2 . The capacities of the Na-IC and Li-ICs decreased by 9% and 3%, respectively, after 1000 cycles of charging and discharging.

  20. Comparison of fracture toughness (K{sub IC}) and strain energy release rate (G) of selected nuclear graphites

    Energy Technology Data Exchange (ETDEWEB)

    Chi, Se-Hwan, E-mail: shchi@kaeri.re.kr

    2016-08-01

    The fracture behaviors of six nuclear graphite grades for a high-temperature gas-cooled reactor (HTGR), which differed in coke particle size and forming method, were characterized based on the ASTM standard graphite fracture toughness test method (ASTM D 7779-11) at room temperature. The G appeared to show good correlation with the fracture surface roughness and the G-Δa curves appeared to describe the fracture process well from crack initiation to failure. Comparison of the local (K{sub IC}) and gross (G{sub IC}, G-Δa) fracture parameters showed that the resistance to crack initiation and propagation was higher in the extruded or vibration molded medium particle size grades (PCEA, NBG-17, NBG-18: EVM group) than in the iso-molded fine particle size grades (IG-110, IG-430, NBG-25: IMF group). The ASTM may need to provide a guideline for G-Δa curve analysis. The K{sub IC} appeared to increase with specimen thickness (size).

  1. Investigation of the applicability of dry powder inhalation in school children

    NARCIS (Netherlands)

    Lexmond, A. J.; Kruizinga, T. J.; Hagedoorn, P.; Frijlink, H. W.; Rottier, B. L.; de Boer, A. H.

    2013-01-01

    Children are an important target group for inhalation therapy, but little is known about their intellectual and inspiratory capacities to operate dry powder inhalers (DPIs). Most studies so far have focused either on a specific DPI, or on (single) inhala- tion parameters and how these are affected

  2. [Pulmonary function of children with acute leukemia in maintenance phase of chemotherapy].

    Science.gov (United States)

    de Macêdo, Thalita Medeiros Fernandes; Campos, Tania Fernandes; Mendes, Raquel Emanuele de França; França, Danielle Corrêa; Chaves, Gabriela Suéllen da Silva; de Mendonça, Karla Morganna Pereira Pinto

    2014-12-01

    The aim of this study was to assess the pulmonary function of children with acute leukemia. Cross-sectional observational analytical study that enrolled 34 children divided into groups A (17 with acute leukemia in the maintenance phase of chemotherapy) and B (17 healthy children). The groups were matched for sex, age and height. Spirometry was measured using a spirometer Microloop Viasys(®) in accordance with American Thoracic Society and European Respiratory Society guidelines. Maximal respiratory pressures were measured with an MVD300 digital manometer (Globalmed(®)). Maximal inspiratory pressures and maximal expiratory pressures were measured from residual volume and total lung capacity, respectively. Group A showed a significant decrease in maximal inspiratory pressures when compared to group B. No significant difference was found between the spirometric values of the two groups, nor was there any difference between maximal inspiratory pressure and maximal expiratory pressure values in group A compared to the lower limit values proposed as reference. Children with acute leukemia, myeloid or lymphoid, during the maintenance phase of chemotherapy exhibited unchanged spirometric variables and maximal expiratory pressure; However, there was a decrease in inspiratory muscle strength. Copyright © 2014 Associação de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  3. Las políticas del espacio público icónico - Seestadt Aspern, la orilla urbana de Viena

    Directory of Open Access Journals (Sweden)

    Katrin Hagen

    2015-02-01

    Full Text Available El siguiente trabajo analiza un proyecto de gran escala, enfatizando en la implementación de políticas del espacio público en el contexto de la globalización. Se parte de la importancia creciente que toma el espacio público en un desarrollo urbano sostenible. Para ello, se aborda la imagen cambiante del espacio público en general y los instrumentos de planificación que buscan su desarrollo sostenible. Las influencias de la globalización se discuten mediante el concepto de la ciudad icónica y el papel que desempeña el espacio público al respecto. Ahora bien, pese a la estrecha vinculación que existe entre las interacciones mencionadas -en cuanto a potenciales problemas y aspectos de calidad-, este concepto de la ciudad icónica ha sido escasamente investigado. Al respecto, el presente trabajo desarrolla un aporte significantivo. Concretamente, se analizan los cambios en las políticas del espacio público en Viena, para el caso de la Seestadt Aspern, en donde se observa una clara tendencia de cambio, que va desde una ‘arquitectura icónica’ hacia un ‘espacio público icónico’.

  4. Creating a FIESTA (Framework for Integrated Earth Science and Technology Applications) with MagIC

    Science.gov (United States)

    Minnett, R.; Koppers, A. A. P.; Jarboe, N.; Tauxe, L.; Constable, C.

    2017-12-01

    The Magnetics Information Consortium (https://earthref.org/MagIC) has recently developed a containerized web application to considerably reduce the friction in contributing, exploring and combining valuable and complex datasets for the paleo-, geo- and rock magnetic scientific community. The data produced in this scientific domain are inherently hierarchical and the communities evolving approaches to this scientific workflow, from sampling to taking measurements to multiple levels of interpretations, require a large and flexible data model to adequately annotate the results and ensure reproducibility. Historically, contributing such detail in a consistent format has been prohibitively time consuming and often resulted in only publishing the highly derived interpretations. The new open-source (https://github.com/earthref/MagIC) application provides a flexible upload tool integrated with the data model to easily create a validated contribution and a powerful search interface for discovering datasets and combining them to enable transformative science. MagIC is hosted at EarthRef.org along with several interdisciplinary geoscience databases. A FIESTA (Framework for Integrated Earth Science and Technology Applications) is being created by generalizing MagIC's web application for reuse in other domains. The application relies on a single configuration document that describes the routing, data model, component settings and external services integrations. The container hosts an isomorphic Meteor JavaScript application, MongoDB database and ElasticSearch search engine. Multiple containers can be configured as microservices to serve portions of the application or rely on externally hosted MongoDB, ElasticSearch, or third-party services to efficiently scale computational demands. FIESTA is particularly well suited for many Earth Science disciplines with its flexible data model, mapping, account management, upload tool to private workspaces, reference metadata, image

  5. Optical observations of the nearby galaxy IC342 with narrow band [SII] and Hα filters. I

    Directory of Open Access Journals (Sweden)

    Vučetić M.M.

    2013-01-01

    Full Text Available We present observations of a portion of the nearby spiral galaxy IC342 using narrow band [SII] and Hα filters. These observations were carried out in November 2011 with the 2m RCC telescope at Rozhen National Astronomical Observatory in Bulgaria. In this paper we report coordinates, diameters, Hα and [SII] fluxes for 203 HII regions detected in two fields of view in IC342 galaxy. The number of detected HII regions is 5 times higher than previously known in these two parts of the galaxy. [Projekat Ministarstva nauke Republike Srbije, br. 176005: Emission nebulae: structure and evolution

  6. Alma Survey of Circumstellar Disks in the Young Stellar Cluster IC 348

    Science.gov (United States)

    Ruíz-Rodríguez, D.; Cieza, L. A.; Williams, J. P.; Andrews, S. M.; Principe, D. A.; Caceres, C.; Canovas, H.; Casassus, S.; Schreiber, M. R.; Kastner, J. H.

    2018-05-01

    We present a 1.3 mm continuum survey of the young (2-3 Myr) stellar cluster IC 348, which lies at a distance of 310 pc, and is dominated by low-mass stars (M⋆ ˜ 0.1-0.6 M⊙). We observed 136 Class II sources (disks that are optically thick in the infrared) at 0.8″ (200 au) resolution with a 3σ sensitivity of ˜ 0.45 mJy (Mdust ˜ 1.3 M⊕). We detect 40 of the targets and construct a mm-continuum luminosity function. We compare the disk mass distribution in IC 348 to those of younger and older regions, taking into account the dependence on stellar mass. We find a clear evolution in disk masses from 1 to 5-10 Myr. The disk masses in IC 348 are significantly lower than those in Taurus (1-3 Myr) and Lupus (1-3 Myr), similar to those of Chamaleon I, (2-3 Myr) and σ Ori (3-5 Myr) and significantly higher than in Upper Scorpius (5-10 Myr). About 20 disks in our sample (˜5% of the cluster members) have estimated masses (dust + gas) >1 MJup and hence might be the precursors of giant planets in the cluster. Some of the most massive disks include transition objects with inner opacity holes based on their infrared SEDs. From a stacking analysis of the 96 non-detections, we find that these disks have a typical dust mass of just ≲ 0.4 M⊕, even though the vast majority of their infrared SEDs remain optically thick and show little signs of evolution. Such low-mass disks may be the precursors of the small rocky planets found by Kepler around M-type stars.

  7. The Magnetics Information Consortium (MagIC) Online Database: Uploading, Searching and Visualizing Paleomagnetic and Rock Magnetic Data

    Science.gov (United States)

    Minnett, R.; Koppers, A.; Tauxe, L.; Constable, C.; Pisarevsky, S. A.; Jackson, M.; Solheid, P.; Banerjee, S.; Johnson, C.

    2006-12-01

    The Magnetics Information Consortium (MagIC) is commissioned to implement and maintain an online portal to a relational database populated by both rock and paleomagnetic data. The goal of MagIC is to archive all measurements and the derived properties for studies of paleomagnetic directions (inclination, declination) and intensities, and for rock magnetic experiments (hysteresis, remanence, susceptibility, anisotropy). MagIC is hosted under EarthRef.org at http://earthref.org/MAGIC/ and has two search nodes, one for paleomagnetism and one for rock magnetism. Both nodes provide query building based on location, reference, methods applied, material type and geological age, as well as a visual map interface to browse and select locations. The query result set is displayed in a digestible tabular format allowing the user to descend through hierarchical levels such as from locations to sites, samples, specimens, and measurements. At each stage, the result set can be saved and, if supported by the data, can be visualized by plotting global location maps, equal area plots, or typical Zijderveld, hysteresis, and various magnetization and remanence diagrams. User contributions to the MagIC database are critical to achieving a useful research tool. We have developed a standard data and metadata template (Version 2.1) that can be used to format and upload all data at the time of publication in Earth Science journals. Software tools are provided to facilitate population of these templates within Microsoft Excel. These tools allow for the import/export of text files and provide advanced functionality to manage and edit the data, and to perform various internal checks to maintain data integrity and prepare for uploading. The MagIC Contribution Wizard at http://earthref.org/MAGIC/upload.htm executes the upload and takes only a few minutes to process several thousand data records. The standardized MagIC template files are stored in the digital archives of EarthRef.org where they

  8. In vitro assays for cobblestone area-forming cells, LTC-IC, and CFU-C

    NARCIS (Netherlands)

    van Os, Ronald P; Dethmers-Ausema, Bertien; de Haan, Gerald; Bunting, Kevin

    2008-01-01

    Various assays exist that measure the function of hematopoietic stemcells (HSCs). In this chapter, in vitro assays are described that measure the frequency of progenitors (colony-forming unit in culture; CFU-C), stem cells (long-term culture-initiating cell; LTC-IC), or both (cobblestone

  9. The time-dependence of the defective nature of ice Ic (cubic ice) and its implications for atmospheric science

    Science.gov (United States)

    Sippel, Christian; Koza, Michael M.; Hansen, Thomas C.; Kuhs, Werner F.

    2010-05-01

    The possible atmospheric implication of ice Ic (cubic ice) has already been suggested some time ago in the context of snow crystal formation [1]. New findings from air-borne measurements in cirrus clouds and contrails have put ice Ic into the focus of interest to understand the so-called "supersaturation puzzle" [2,3,4]. Our recent microstructural work on ice Ic [5,6] appears to be highly relevant in this context. We have found that ice Ic is characterized by a complex stacking fault pattern, which changes as a function of temperature as well as time. Indeed, from our own [7] and other group's work [8] one knows that (in contrast to earlier believe) ice Ic can form up to temperatures at least as high as 240K - thus in the relevant range for cirrus clouds. We have good preliminary evidence that the "cubicity" (which can be related to stacking fault probabilities) as well as the particle size of ice Ic are the relevant parameters for this correlation. The "cubicity" of stacking faulty ice Ic (established by diffraction) correlates nicely with the increased supersaturation at decreasing temperatures observed in cirrus clouds and contrails, a fact, which may be considered as further evidence for the presence of ice Ic. Recently, we have studied the time-dependency of the changes in both "cubicity" and particle size at various temperatures of relevance for cirrus clouds and contrails by in-situ neutron powder diffraction. The timescales over which changes occur (several to many hours) are similar to the life-time of cirrus clouds and contrails and suggest that the supersaturation situation may change within this time span in the natural environment too. Some accompanying results obtained by cryo-SEM (scanning electron microscopy) work will also be presented and suggest that stacking-faulty ice Ic has kinky surfaces providing many more active centres for heterogeneous reactions on the surface than in the usually assumed stable hexagonal form of ice Ih with its rather

  10. PREFACE: 2nd International Conference on Mathematical Modeling in Physical Sciences 2013 (IC-MSQUARE 2013)

    Science.gov (United States)

    2014-03-01

    The second International Conference on Mathematical Modeling in Physical Sciences (IC-MSQUARE) took place at Prague, Czech Republic, from Sunday 1 September to Thursday 5 September 2013. The Conference was attended by more than 280 participants and hosted about 400 oral, poster, and virtual presentations while counted more than 600 pre-registered authors. The second IC-MSQUARE consisted of different and diverging workshops and thus covered various research fields where Mathematical Modeling is used, such as Theoretical/Mathematical Physics, Neutrino Physics, Non-Integrable Systems, Dynamical Systems, Computational Nanoscience, Biological Physics, Computational Biomechanics, Complex Networks, Stochastic Modeling, Fractional Statistics, DNA Dynamics, Macroeconomics. The scientific program was rather heavy since after the Keynote and Invited Talks in the morning, three parallel sessions were running every day. However, according to all attendees, the program was excellent with high level of talks and the scientific environment was fruitful, thus all attendees had a creative time. We would like to thank the Keynote Speaker and the Invited Speakers for their significant contribution to IC-MSQUARE. We also would like to thank the Members of the International Advisory and Scientific Committees as well as the Members of the Organizing Committee. Further information on the editors, speakers and committees is available in the attached pdf.

  11. Inspiratory impedance during active compression-decompression cardiopulmonary resuscitation: a randomized evaluation in patients in cardiac arrest.

    Science.gov (United States)

    Plaisance, P; Lurie, K G; Payen, D

    2000-03-07

    Blood pressure is severely reduced in patients in cardiac arrest receiving standard cardiopulmonary resuscitation (CPR). Although active compression-decompression (ACD) CPR improves acute hemodynamic parameters, arterial pressures remain suboptimal with this technique. We performed ACD CPR in patients with a new inspiratory threshold valve (ITV) to determine whether lowering intrathoracic pressures during the "relaxation" phase of ACD CPR would enhance venous blood return and overall CPR efficiency. This prospective, randomized, blinded trial was performed in prehospital mobile intensive care units in Paris, France. Patients in nontraumatic cardiac arrest received ACD CPR plus the ITV or ACD CPR alone for 30 minutes during advanced cardiac life support. End tidal CO(2) (ETCO(2)), diastolic blood pressure (DAP) and coronary perfusion pressure, and time to return of spontaneous circulation (ROSC) were measured. Groups were similar with respect to age, gender, and initial rhythm. Mean maximal ETCO(2), coronary perfusion pressure, and DAP values, respectively (in mm Hg), were 13.1+/-0.9, 25.0+/-1.4, and 36.5+/-1.5 with ACD CPR alone versus 19.1+/-1.0, 43.3+/-1.6, and 56.4+/-1.7 with ACD plus valve (PCPR alone after 26.5+/-0.7 minutes versus 4 of 11 patients with ACD CPR plus ITV after 19.8+/-2.8 minutes (PCPR increases the efficiency of CPR, leading to diastolic arterial pressures of >50 mm Hg. The long-term benefits of this new CPR technology are under investigation.

  12. Testbed diversity as a fundamental principle for effective ICS security research

    OpenAIRE

    Green, Benjamin; Frey, Sylvain Andre Francis; Rashid, Awais; Hutchison, David

    2016-01-01

    The implementation of diversity in testbeds is essential to understanding and improving the security and resilience of Industrial Control Systems (ICS). Employing a wide spec- trum of equipment, diverse networks, and business processes, as deployed in real-life infrastructures, is particularly diffi- cult in experimental conditions. However, this level of di- versity is key from a security perspective, as attackers can exploit system particularities and process intricacies to their advantage....

  13. LDL oxidation, antioxidant capacity and growth of cultured grey mullet ( Mugil cephalus ) fed dietary sorghum distillery residue pretreated with polyethylene glycol.

    Science.gov (United States)

    Lee, Shin Mei; Cheng, Hui Ling; Pan, Bonnie Sun

    2009-09-09

    Dietary sorghum distillery residue (SDR) showed antioxidant and blood thinning effects on grey mullet during winter, but inhibited their growth. The objective of this study was to establish a preliminary treatment of the dietary SDR with polyethylene glycol (PEG), a tannin-binding agent, to enhance growth and blood antioxidant capacity of grey mullet ( Mugil cephalus ) feed. The feeding trial was carried out from June to November. The water temperature was between 25 and 30 degrees C; the specific growth rate of mullet was reduced significantly by feeding diet containing 20% SDR in comparison to fish fed the control diet or diet containing 20% SDR and PEG. In the period of October-November, the water temperature decreased to 19-25 degrees C; the specific growth rates of the 20% SDR-PEG group and the 20% SDR group were 0.13 and 0.19% day(-1), respectively, significantly higher than those fed the control diet (0.07% day(-1)). Feeding with 20% SDR or 20% SDR-PEG diets resulted in prolonged lag phase of low-density lipoprotein (LDL) oxidation compared to fish fed the control diet. The total antioxidant capacity of the plasma of the grey mullet fed 20% SDR-PEG was 1.24 mmol/L, significantly higher than those in the fish fed 20% SDR diet (0.84 mmol/L) or the control (0.72 mmol/L). In vivo observations found that preliminary treatment of SDR with PEG eliminated the endogenous undesirable growth inhibitory factors but maintained its protective effects against LDL oxidation in blood and improved the total antioxidant capacity and cold adaptation of grey mullet. The ethanol extract of SDR contained 31.9 +/- 7.8 mg/g gallic acids equivalent. The concentration needed to scavenge 50% of the DPPH radicals (IC(50)) was 0.86 mg/mL. Increased gallic acid equivalent and decreased IC(50) of DPPH scavenging activity of SDR fed to fish increased the total antioxidant capacity in blood plasma of grey mullet significantly.

  14. The basic circuit of the IC: tectothalamic neurons with different patterns of synaptic organization send different messages to the thalamus

    Science.gov (United States)

    Ito, Tetsufumi; Oliver, Douglas L.

    2012-01-01

    The inferior colliculus (IC) in the midbrain of the auditory system uses a unique basic circuit to organize the inputs from virtually all of the lower auditory brainstem and transmit this information to the medial geniculate body (MGB) in the thalamus. Here, we review the basic circuit of the IC, the neuronal types, the organization of their inputs and outputs. We specifically discuss the large GABAergic (LG) neurons and how they differ from the small GABAergic (SG) and the more numerous glutamatergic neurons. The somata and dendrites of LG neurons are identified by axosomatic glutamatergic synapses that are lacking in the other cell types and exclusively contain the glutamate transporter VGLUT2. Although LG neurons are most numerous in the central nucleus of the IC (ICC), an analysis of their distribution suggests that they are not specifically associated with one set of ascending inputs. The inputs to ICC may be organized into functional zones with different subsets of brainstem inputs, but each zone may contain the same three neuron types. However, the sources of VGLUT2 axosomatic terminals on the LG neuron are not known. Neurons in the dorsal cochlear nucleus, superior olivary complex, intermediate nucleus of the lateral lemniscus, and IC itself that express the gene for VGLUT2 only are the likely origin of the dense VGLUT2 axosomatic terminals on LG tectothalamic neurons. The IC is unique since LG neurons are GABAergic tectothalamic neurons in addition to the numerous glutamatergic tectothalamic neurons. SG neurons evidently target other auditory structures. The basic circuit of the IC and the LG neurons in particular, has implications for the transmission of information about sound through the midbrain to the MGB. PMID:22855671

  15. Effects of aerobic training combined with respiratory muscle stretching on the functional exercise capacity and thoracoabdominal kinematics in patients with COPD: a randomized and controlled trial

    Directory of Open Access Journals (Sweden)

    Wada JT

    2016-10-01

    Full Text Available Juliano T Wada,1 Erickson Borges-Santos,1 Desiderio Cano Porras,1 Denise M Paisani,1 Alberto Cukier,2 Adriana C Lunardi,1 Celso RF Carvalho1 1Department of Physical Therapy, 2Department of Cardiopneumology, School of Medicine, University of Sao Paulo, Sao Paulo, Brazil Background: Patients with COPD present a major recruitment of the inspiratory muscles, predisposing to chest incoordination, increasing the degree of dyspnea and impairing their exercise capacity. Stretching techniques could decrease the respiratory muscle activity and improve their contractile capacity; however, the systemic effects of stretching remain unknown.Objective: The aim of this study was to evaluate the effects of aerobic training combined with respiratory muscle stretching on functional exercise capacity and thoracoabdominal kinematics in patients with COPD.Design: This study was a randomized and controlled trial.Participants: A total of 30 patients were allocated to a treatment group (TG or a control group (CG; n=15, each group.Intervention: The TG was engaged in respiratory muscle stretching and the CG in upper and lower limb muscle stretching. Both groups performed 24 sessions (twice a week, 12 weeks of aerobic training.Evaluations: Functional exercise capacity (6-minute walk test, thoracoabdominal kinematics (optoelectronic plethysmography, and respiratory muscle activity (surface electromyography were evaluated during exercise. Analysis of covariance was used to compare the groups at a significance level of 5%.Results: After the intervention, the TG showed improved abdominal (ABD contribution, compartmental volume, mobility, and functional exercise capacity with decreased dyspnea when compared with the CG (P<0.01. The TG also showed a decreased respiratory muscle effort required to obtain the same pulmonary volume compared to the CG (P<0.001.Conclusion: Our results suggest that aerobic training combined with respiratory muscle stretching increases the functional

  16. An Ultra-Low-Power RFID/NFC Frontend IC Using 0.18 μm CMOS Technology for Passive Tag Applications

    Directory of Open Access Journals (Sweden)

    Mayukh Bhattacharyya

    2018-05-01

    Full Text Available Battery-less passive sensor tags based on RFID or NFC technology have achieved much popularity in recent times. Passive tags are widely used for various applications like inventory control or in biotelemetry. In this paper, we present a new RFID/NFC frontend IC (integrated circuit for 13.56 MHz passive tag applications. The design of the frontend IC is compatible with the standard ISO 15693/NFC 5. The paper discusses the analog design part in details with a brief overview of the digital interface and some of the critical measured parameters. A novel approach is adopted for the demodulator design, to demodulate the 10% ASK (amplitude shift keying signal. The demodulator circuit consists of a comparator designed with a preset offset voltage. The comparator circuit design is discussed in detail. The power consumption of the bandgap reference circuit is used as the load for the envelope detection of the ASK modulated signal. The sub-threshold operation and low-supply-voltage are used extensively in the analog design—to keep the power consumption low. The IC was fabricated using 0.18 μ m CMOS technology in a die area of 1.5 mm × 1.5 mm and an effective area of 0.7 m m 2 . The minimum supply voltage desired is 1.2 V, for which the total power consumption is 107 μ W. The analog part of the design consumes only 36 μ W, which is low in comparison to other contemporary passive tags ICs. Eventually, a passive tag is developed using the frontend IC, a microcontroller, a temperature and a pressure sensor. A smart NFC device is used to readout the sensor data from the tag employing an Android-based application software. The measurement results demonstrate the full passive operational capability. The IC is suitable for low-power and low-cost industrial or biomedical battery-less sensor applications. A figure-of-merit (FOM is proposed in this paper which is taken as a reference for comparison with other related state-of-the-art researches.

  17. An Ultra-Low-Power RFID/NFC Frontend IC Using 0.18 μm CMOS Technology for Passive Tag Applications.

    Science.gov (United States)

    Bhattacharyya, Mayukh; Gruenwald, Waldemar; Jansen, Dirk; Reindl, Leonhard; Aghassi-Hagmann, Jasmin

    2018-05-07

    Battery-less passive sensor tags based on RFID or NFC technology have achieved much popularity in recent times. Passive tags are widely used for various applications like inventory control or in biotelemetry. In this paper, we present a new RFID/NFC frontend IC (integrated circuit) for 13.56 MHz passive tag applications. The design of the frontend IC is compatible with the standard ISO 15693/NFC 5. The paper discusses the analog design part in details with a brief overview of the digital interface and some of the critical measured parameters. A novel approach is adopted for the demodulator design, to demodulate the 10% ASK (amplitude shift keying) signal. The demodulator circuit consists of a comparator designed with a preset offset voltage. The comparator circuit design is discussed in detail. The power consumption of the bandgap reference circuit is used as the load for the envelope detection of the ASK modulated signal. The sub-threshold operation and low-supply-voltage are used extensively in the analog design—to keep the power consumption low. The IC was fabricated using 0.18 μ m CMOS technology in a die area of 1.5 mm × 1.5 mm and an effective area of 0.7 m m 2 . The minimum supply voltage desired is 1.2 V, for which the total power consumption is 107 μ W. The analog part of the design consumes only 36 μ W, which is low in comparison to other contemporary passive tags ICs. Eventually, a passive tag is developed using the frontend IC, a microcontroller, a temperature and a pressure sensor. A smart NFC device is used to readout the sensor data from the tag employing an Android-based application software. The measurement results demonstrate the full passive operational capability. The IC is suitable for low-power and low-cost industrial or biomedical battery-less sensor applications. A figure-of-merit (FOM) is proposed in this paper which is taken as a reference for comparison with other related state-of-the-art researches.

  18. High-precision analog circuit technology for power supply integrated circuits; Dengen IC yo koseido anarogu kairo gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    Nakamori, A.; Suzuki, T.; Mizoe, K. [Fuji Electric Corporate Research and Development,Ltd., Kanagawa (Japan)

    2000-08-10

    With the recent rapid spread of portable electronic appliances, specification requirements such as compact power supply and long operation with batteries have become severer. Power supply ICs (integrated circuits) are required to reduce power consumption in the circuit and perform high-precision control. To meet these requirements, Fuji Electric develops high-precision CMOS (complementary metal-oxide semiconductor) analog technology. This paper describes three analog circuit technologies of a voltage reference, an operational amplifier and a comparator as circuit components particularly important for the precision of power supply ICs. (author)

  19. Automatic analog IC sizing and optimization constrained with PVT corners and layout effects

    CERN Document Server

    Lourenço, Nuno; Horta, Nuno

    2017-01-01

    This book introduces readers to a variety of tools for automatic analog integrated circuit (IC) sizing and optimization. The authors provide a historical perspective on the early methods proposed to tackle automatic analog circuit sizing, with emphasis on the methodologies to size and optimize the circuit, and on the methodologies to estimate the circuit’s performance. The discussion also includes robust circuit design and optimization and the most recent advances in layout-aware analog sizing approaches. The authors describe a methodology for an automatic flow for analog IC design, including details of the inputs and interfaces, multi-objective optimization techniques, and the enhancements made in the base implementation by using machine leaning techniques. The Gradient model is discussed in detail, along with the methods to include layout effects in the circuit sizing. The concepts and algorithms of all the modules are thoroughly described, enabling readers to reproduce the methodologies, improve the qual...

  20. Simulation of a class of hazardous situations in the ICS «INM RAS - Baltic Sea»

    Science.gov (United States)

    Zakharova, Natalia; Agoshkov, Valery; Aseev, Nikita; Parmuzin, Eugene; Sheloput, Tateana; Shutyaev, Victor

    2017-04-01

    Development of Informational Computational Systems (ICS) for data assimilation procedures is one of multidisciplinary problems. To study and solve these problems one needs to apply modern results from different disciplines and recent developments in mathematical modeling, theory of adjoint equations and optimal control, inverse problems, numerical methods theory, numerical algebra, scientific computing and processing of satellite data. In this work the results on the ICS development for PC-ICS "INM RAS - Baltic Sea" are presented. We discuss practical problems studied by ICS. The System includes numerical model of the Baltic Sea thermodynamics, the new oil spill model describing the propagation of a slick at the Sea surface (Agoshkov, Aseev et al., 2014) and the optimal ship route calculating block (Agoshkov, Zayachkovsky et al., 2014). The ICS is based on the INMOM numerical model of the Baltic Sea thermodynamics (Zalesny et al., 2013). It is possible to calculate main hydrodynamic parameters (temperature, salinity, velocities, sea level) using user-friendly interface of the ICS. The System includes data assimilation procedures (Agoshkov, 2003, Parmuzin, Agoshkov, 2012) and one can use the block of variational assimilation of the sea surface temperature in order to obtain main hydrodynamic parameters. Main possibilities of the ICS and several numerical experiments are presented in the work. By the problem of risk control is meant a problem of determination of optimal resources quantity which are necessary for decreasing the risk to some acceptable value. Mass of oil slick is chosen as a function of control. For the realization of the random variable the quadratic "functional of cost" is introduced. It comprises cleaning costs and deviation of damage of oil pollution from its acceptable value. The problem of minimization of this functional is solved based on the methods of optimal control and the theory of adjoint equations. The solution of this problem is

  1. Differential diagnosis between aneurysm and infundibular dilatation in the IC-PC region with 3D-CTA

    International Nuclear Information System (INIS)

    Kubota, Tsukasa; Niwa, Jun; Tanigawara, Tetsuya; Chiba, Masahiko; Akiyama, Yukinori; Inamura Shigeru

    2000-01-01

    In cases of asymptomatic internal carotid-posterior communicating artery (IC-PC) protrusions, it is sometimes difficult to differentiate infundibular dilatation (ID) from aneurysm by digital subtraction angiography. We applied three-dimensional CT angiography (3D-CTA) in 32 cases of these IC-PC protrusions. SOMATOM PLUS 4 was used under such conditions as to provide images with high spatial resolution. The shaded surface display (SSD) method was adopted to reconstruct the 3D images because of its advantage in separating overlapped vasculature. We also made reference to source images and maximum intensity projection (MIP) to make sure of our diagnoses. In all cases including 4 aneurysms and 28 IDs, we were able to distinguish between ID and aneurysm. The accuracy of 3D-CTA was confirmed by 9 surgical cases. Our technique was as follows: To inject a high dose of diluted contrast medium rapidly to smaller arteries for opacification of contrast medium. To exclude neighboring useless structures except for the very close structures such as posterior clinoid process from the target image focusing on the IC-PC region. To observe the reconstructed image of MIP and SSD from various angles. The contralateral and craniocaudal view were valuable. To change the threshold level gradually and observe the configurational changes of the apex of protrusion. Poorly developed PcomA was mostly delineated at the optimum threshold level. Otherwise, the apex of protrusion remained spherical in an aneurysm and became pyramidal in shape in an ID when the threshold level was gradually decreased. In conclusion, 3D-CTA was a useful modality for IC-PC protrusions to distinguish between ID and aneurysm. (author)

  2. The Influence of Cyst Emptying, Lymph Node Resection and Chemotherapy on Survival in Stage IA and IC1 Epithelial Ovarian Cancer

    DEFF Research Database (Denmark)

    Rosendahl, Mikkel; Mosgaard, Berit Jul; Høgdall, Claus

    2016-01-01

    AIM: To determine if survival in stage I ovarian cancer is influenced by cyst emptying, lymph node resection and chemotherapy. PATIENTS AND METHODS: A survival analysis of 607 patients with ovarian cancer in stage IA, IA with cyst emptying (IAempty) and IC1 was performed. RESULTS......: There was no difference in five-year survival between IA (87%) and IC1 (87%) (p=0.899), between IA and IAempty (86%) (p=0.500) nor between IA+IAempty (87%) and IC1 without IAempty (84%) (p=0.527). Five-year survival rate (5YSR) was significantly higher after lymph node resection in stage IA (94% vs. 85%; p=0.01) and IA......+IC1 (93% vs. 85%; p=0.004). In multivariate analysis, lymph node resection improved prognosis significantly for all sub-stages, whereas stage and chemotherapy did not affect survival. CONCLUSION: In stage IA ovarian cancer, controlled cyst emptying without spill does not worsen prognosis. Lymph node...

  3. Making the MagIC (Magnetics Information Consortium) Web Application Accessible to New Users and Useful to Experts

    Science.gov (United States)

    Minnett, R.; Koppers, A.; Jarboe, N.; Tauxe, L.; Constable, C.; Jonestrask, L.

    2017-12-01

    Challenges are faced by both new and experienced users interested in contributing their data to community repositories, in data discovery, or engaged in potentially transformative science. The Magnetics Information Consortium (https://earthref.org/MagIC) has recently simplified its data model and developed a new containerized web application to reduce the friction in contributing, exploring, and combining valuable and complex datasets for the paleo-, geo-, and rock magnetic scientific community. The new data model more closely reflects the hierarchical workflow in paleomagnetic experiments to enable adequate annotation of scientific results and ensure reproducibility. The new open-source (https://github.com/earthref/MagIC) application includes an upload tool that is integrated with the data model to provide early data validation feedback and ease the friction of contributing and updating datasets. The search interface provides a powerful full text search of contributions indexed by ElasticSearch and a wide array of filters, including specific geographic and geological timescale filtering, to support both novice users exploring the database and experts interested in compiling new datasets with specific criteria across thousands of studies and millions of measurements. The datasets are not large, but they are complex, with many results from evolving experimental and analytical approaches. These data are also extremely valuable due to the cost in collecting or creating physical samples and the, often, destructive nature of the experiments. MagIC is heavily invested in encouraging young scientists as well as established labs to cultivate workflows that facilitate contributing their data in a consistent format. This eLightning presentation includes a live demonstration of the MagIC web application, developed as a configurable container hosting an isomorphic Meteor JavaScript application, MongoDB database, and ElasticSearch search engine. Visitors can explore the MagIC

  4. Electromigration in 3D-IC scale Cu/Sn/Cu solder joints

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Cheng-En, E-mail: ceho1975@hotmail.com; Lee, Pei-Tzu; Chen, Chih-Nan; Yang, Cheng-Hsien

    2016-08-15

    The electromigration effect on the three-dimensional integrated circuits (3D-IC) scale solder joints with a Cu/Sn(25–50 μm)/Cu configuration was investigated using a field-emission scanning electron microscope (FE–SEM) combined with electron backscatter diffraction (EBSD) analysis system. Electron current stressing for a few days caused the pronounced accumulation of Cu{sub 6}Sn{sub 5} in specific Sn grain boundaries (GBs). The EBSD analysis indicated that both the β-Sn crystallographic orientation and GB orientation play dominant roles in this accumulation. The dependencies of the Cu{sub 6}Sn{sub 5} accumulation on the two above factors (i.e., Sn grain orientation and GB orientation) can be well rationalized via a proposed mathematic model based on the Huntington and Grone's electromigration theory with the Cu anisotropic diffusion data in a β-Sn lattice. - Highlights: • Anisotropic Cu electromigration in the 3D-IC scale microelectronic solder joints. • Pronounced accumulation of Cu{sub 6}Sn{sub 5} intermetallic in specific Sn grain boundaries. • A linear dependence of Cu{sub 6}Sn{sub 5} accumulation over the current stressing time. • β-Sn and grain boundary orientations are the dominant factors in Cu{sub 6}Sn{sub 5} accumulation.

  5. Using Tablet PCs and Interactive Software in IC Design Courses to Improve Learning

    Science.gov (United States)

    Simoni, M.

    2011-01-01

    This paper describes an initial study of using tablet PCs and interactive course software in integrated circuit (IC) design courses. A rapidly growing community is demonstrating how this technology can improve learning and retention of material by facilitating interaction between faculty and students via cognitive exercises during lectures. While…

  6. Tipe Mating pada Empat Isolat Thanatephorus Cucumeris Anamorf: Rhizoctonia solani Anastomosis Group (AG 1-IC

    Directory of Open Access Journals (Sweden)

    Achmadi Priyatmojo

    2006-12-01

    Full Text Available Four parent isolates (189, Rh28, BW3 and F-1 of Thanatephorus cucumeris (anamorph: Rhizoctonia solani AG 1-IC were induced to produce basidiospores using soil-over culture method. All of four parent isolates could produce basidiospores. Colonies obtained from single basidiospore isolate of each parent isolate were paired on charcoal potato dextrose agar. Single basidiospore isolate having different mating type produced tuft at area of the junction of paired colonies. On the based of tuft formation, single basidiospore isolates of each parent isolate could be divided into two different mating types, therefore it is concluded that each of 189, Rh28, BW3 and F-1 isolate of T. cucumeris AG I-IC has bipolar mating type.

  7. Practical silicon Light emitting devices fabricated by standard IC technology

    International Nuclear Information System (INIS)

    Aharoni, H.; Monuko du Plessis; Snyman, L.W.

    2004-01-01

    Full Text:Research activities are described with regard to the development of a comprehensive approach for the practical realization of single crystal Silicon Light Emitting Devices (Si-LEDs). Several interesting suggestions for the fabrication of such devices were made in the literature but they were not adopted by the semiconductor industry because they involve non-standard fabrication schemes, requiring special production lines. Our work presents an alternative approach, proposed and realized in practice by us, permitting the fabrication of Si-LEDs using the standard conventional fully industrialized IC technology ''as is'' without any adaptation. It enables their fabrication in the same production lines of the presently existing IC industry. This means that Si-LEDs can now be fabricated simultaneously with other components, such as transistors, on the same silicon chip, using the same masks and processing procedures. The result is that the yield, reliability, and price of the above Si-LEDs are the same as the other Si devices integrated on the same chip. In this work some structural details of several practical Si-LED's designed by us, as well as experimental results describing their performance are presented. These Si-LED's were fabricated to our specifications utilizing standard CMOS/BiCMOS technology, a fact which comprises an achievement by itself. The structure of the Si-LED's, is designed according to specifications such as the required operating voltage, overall light output intensity, its dependence(linear, or non-linear) on the input signal (voltage or current), light generations location (bulk, or near-surface), the emission pattern and uniformity. Such structural design present a problem since the designer can not use any structural parameters (such as doping levels and junction depths for example) but only those which already exist in the production lines. Since the fabrication procedures in these lines are originally designed for processing of

  8. Exploring physical and chemical factors influencing the properties of recombinant prion protein and the real-time quaking-induced conversion (RT-QuIC) assay.

    Science.gov (United States)

    Cheng, Keding; Sloan, Angela; Avery, Kristen M; Coulthart, Michael; Carpenter, Michael; Knox, J David

    2014-01-01

    Real-time quaking-induced conversion (RT-QuIC), a highly specific and sensitive assay able to detect low levels of the disease-inducing isoform of the prion protein (PrP(d)) in brain tissue biopsies and cerebral spinal fluid, has great potential to become a method for diagnosing prion disease ante mortem. In order to standardize the assay method for routine analysis, an understanding of how physical and chemical factors affect the stability of the recombinant prion protein (rPrP) substrate and the RT-QuIC assay's sensitivity, specificity, and reproducibility is required. In this study, using sporadic Creutzfeldt-Jakob Disease brain homogenate to seed the reactions and an in vitro-expressed recombinant prion protein, hamster rPrP, as the substrate, the following factors affecting the RT-QuIC assay were examined: salt and substrate concentrations, substrate storage, and pH. Results demonstrated that both the generation of the quality and quantities of rPrP substrate critical to the reaction, as well as the RT-QuIC reaction itself required strict adherence to specific physical and chemical conditions. Once optimized, the RT-QuIC assay was confirmed to be a very specific and sensitive assay method for sCJD detection. Findings in this study indicate that further optimization and standardization of RT-QuIC assay is required before it can be adopted as a routine diagnostic test.

  9. Hepatoprotective and antioxidant capacity of Melochia corchorifolia extracts.

    Science.gov (United States)

    Rao, B Ganga; Rao, Y Venkateswara; Rao, T Mallikarjuna

    2013-07-01

    To evaluate hepato protective and antioxidant capacity of Melochia corchorifolia (M. corchorifolia) aerial part extracts. Antioxidant activity was evaluated by using three free radicals (Superoxide, Hydroxyl and DPPH) and hepatoprotective activity was assessed against CCl4 induced liver intoxication in rats. The extracts produced concentration dependent percentage protection in decrease of serum enzymes and percentage inhibition on free radicals. Among all extracts methanol extract showed better activity with percentage protection of SGOT (78.98%), SGPT (79.65%), ALP (82.48%) and total bilirubin (80.0%) levels against CCl4 liver intoxication and also methanolic extract showed better activity with IC50 values on superoxide, hydroxyl and DPPH radicals were 127 μ g, 240 μ g and 179 μ g. From the results obtained during the study it could be concluded that M. corchorifolia aerial part extracts have antioxidant and hepatoprotective components. Further study is necessary for isolation and characterization of bioactive molecules which are responsible for hepatoprotective and antioxidant activity. Copyright © 2013 Hainan Medical College. Published by Elsevier B.V. All rights reserved.

  10. Nonlinear concentration gradients regulated by the width of channels for observation of half maximal inhibitory concentration (IC50) of transporter proteins.

    Science.gov (United States)

    Abe, Yuta; Kamiya, Koki; Osaki, Toshihisa; Sasaki, Hirotaka; Kawano, Ryuji; Miki, Norihisa; Takeuchi, Shoji

    2015-08-21

    This paper describes a simple microfluidic device that can generate nonlinear concentration gradients. We changed the "width" of channels that can drastically shorten the total microfluidic channel length and simplify the microfluidic network design rather than the "length" of channels. The logarithmic concentration gradients generated by the device were in good agreement with those obtained by simulation. Using this device, we evaluated a probable IC50 value of the ABC transporter proteins by the competitive transport assays at five different logarithmic concentrations. This probable IC50 value was in good agreement with an IC50 value (0.92 μM) obtained at the diluted concentrations of seven points.

  11. uvby and Hβ photometry of the open cluster IC 4996

    International Nuclear Information System (INIS)

    Alfaro, E.J.; Delgado, A.J.; Garcia-Pelayo, J.M.; Garrido, R.; Saez, M.

    1985-01-01

    Photoelectric uvby and Hβ observations have been obtained for 15 stars in the field of the open cluster IC 4996. An average colour excess of E(b-y)=0.473 is estimated for six observed members of the cluster, in good agreement with previous results. A comparison between the β-Msub(v) calibrations given by Crawford and by Eggen suggests that the first one takes better into account the evolutionary effects on the Hβ index. We have calculated a true distance modulus of 11.43 and an age of 7.5x10 6 years

  12. Comparative evaluation of structural integrity for ITER blanket shield block based on SDC-IC and ASME code

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Hee-Jin [ITER Korea, National Fusion Research Institute, 169-148 Gwahak-Ro, Yuseong-Gu, Daejeon (Korea, Republic of); Ha, Min-Su, E-mail: msha12@nfri.re.kr [ITER Korea, National Fusion Research Institute, 169-148 Gwahak-Ro, Yuseong-Gu, Daejeon (Korea, Republic of); Kim, Sa-Woong; Jung, Hun-Chea [ITER Korea, National Fusion Research Institute, 169-148 Gwahak-Ro, Yuseong-Gu, Daejeon (Korea, Republic of); Kim, Duck-Hoi [ITER Organization, Route de Vinon sur Verdon - CS 90046, 13067 Sant Paul Lez Durance (France)

    2016-11-01

    Highlights: • The procedure of structural integrity and fatigue assessment was described. • Case studies were performed according to both SDC-IC and ASME Sec. • III codes The conservatism of the ASME code was demonstrated. • The study only covers the specifically comparable case about fatigue usage factor. - Abstract: The ITER blanket Shield Block is a bulk structure to absorb radiation and to provide thermal shielding to vacuum vessel and external vessel components, therefore the most significant load for Shield Block is the thermal load. In the previous study, the thermo-mechanical analysis has been performed under the inductive operation as representative loading condition. And the fatigue evaluations were conducted to assure structural integrity for Shield Block according to Structural Design Criteria for In-vessel Components (SDC-IC) which provided by ITER Organization (IO) based on the code of RCC-MR. Generally, ASME code (especially, B&PV Sec. III) is widely applied for design of nuclear components, and is usually well known as more conservative than other specific codes. For the view point of the fatigue assessment, ASME code is very conservative compared with SDC-IC in terms of the reflected K{sub e} factor, design fatigue curve and other factors. Therefore, an accurate fatigue assessment comparison is needed to measure of conservatism. The purpose of this study is to provide the fatigue usage comparison resulting from the specified operating conditions shall be evaluated for Shield Block based on both SDC-IC and ASME code, and to discuss the conservatism of the results.

  13. Comparative evaluation of structural integrity for ITER blanket shield block based on SDC-IC and ASME code

    International Nuclear Information System (INIS)

    Shim, Hee-Jin; Ha, Min-Su; Kim, Sa-Woong; Jung, Hun-Chea; Kim, Duck-Hoi

    2016-01-01

    Highlights: • The procedure of structural integrity and fatigue assessment was described. • Case studies were performed according to both SDC-IC and ASME Sec. • III codes The conservatism of the ASME code was demonstrated. • The study only covers the specifically comparable case about fatigue usage factor. - Abstract: The ITER blanket Shield Block is a bulk structure to absorb radiation and to provide thermal shielding to vacuum vessel and external vessel components, therefore the most significant load for Shield Block is the thermal load. In the previous study, the thermo-mechanical analysis has been performed under the inductive operation as representative loading condition. And the fatigue evaluations were conducted to assure structural integrity for Shield Block according to Structural Design Criteria for In-vessel Components (SDC-IC) which provided by ITER Organization (IO) based on the code of RCC-MR. Generally, ASME code (especially, B&PV Sec. III) is widely applied for design of nuclear components, and is usually well known as more conservative than other specific codes. For the view point of the fatigue assessment, ASME code is very conservative compared with SDC-IC in terms of the reflected K_e factor, design fatigue curve and other factors. Therefore, an accurate fatigue assessment comparison is needed to measure of conservatism. The purpose of this study is to provide the fatigue usage comparison resulting from the specified operating conditions shall be evaluated for Shield Block based on both SDC-IC and ASME code, and to discuss the conservatism of the results.

  14. Utilizing Forced Vital Capacity to Predict Low Lung Compliance and Select Intraoperative Tidal Volume During Thoracic Surgery.

    Science.gov (United States)

    Hoftman, Nir; Eikermann, Eric; Shin, John; Buckley, Jack; Navab, Kaveh; Abtin, Fereidoun; Grogan, Tristan; Cannesson, Maxime; Mahajan, Aman

    2017-12-01

    Tidal volume selection during mechanical ventilation utilizes dogmatic formulas that only consider a patient's predicted body weight (PBW). In this study, we investigate whether forced vital capacity (FVC) (1) correlates better to total lung capacity (TLC) than PBW, (2) predicts low pulmonary compliance, and (3) provides an alternative method for tidal volume selection. One hundred thirty thoracic surgery patients had their preoperative TLC calculated via 2 methods: (1) pulmonary function test (PFT; TLCPFT) and (2) computed tomography 3D reconstruction (TLCCT). We compared the correlation between TLC and PBW with the correlation between TLC and FVC to determine which was stronger. Dynamic pulmonary compliance was then calculated from intraoperative ventilator data and logistic regression models constructed to determine which clinical measure best predicted low compliance. Ratios of tidal volume/FVC plotted against peak inspiratory pressure were utilized to construct a new model for tidal volume selection. Calculated tidal volumes generated by this model were then compared with those generated by the standard lung-protective formula Vt = 7 cc/kg. The correlation between FVC and TLC (0.82 for TLCPFT and 0.76 for TLCCT) was stronger than the correlation between PBW and TLC (0.65 for TLCPFT and 0.58 for TLCCT). Patients with very low compliance had significantly smaller lung volumes (forced expiratory volume at 1 second, FVC, TLC) and lower diffusion capacity of the lungs for carbon monoxide when compared with patients with normal compliance. An FVC cutoff of 3470 cc was 100% sensitive and 51% specific for predicting low compliance. The proposed equation Vt = FVC/8 significantly reduced calculated tidal volume by a mean of 22.5% in patients with low pulmonary compliance without affecting the mean tidal volume in patients with normal compliance (mean difference 0.9%). FVC is more strongly correlated to TLC than PBW and a cutoff of about 3.5 L can be utilized to predict

  15. An Investigation of the Antioxidant Capacity in Extracts from Moringa oleifera Plants Grown in Jamaica

    Science.gov (United States)

    Wright, Racquel J.; Lee, Ken S.; Hyacinth, Hyacinth I.; Hibbert, Jacqueline M.; Reid, Marvin E.; Wheatley, Andrew O.

    2017-01-01

    Moringa oleifera trees grow well in Jamaica and their parts are popularly used locally for various purposes and ailments. Antioxidant activities in Moringa oleifera samples from different parts of the world have different ranges. This study was initiated to determine the antioxidant activity of Moringa oleifera grown in Jamaica. Dried and milled Moringa oleifera leaves were extracted with ethanol/water (4:1) followed by a series of liquid–liquid extractions. The antioxidant capacities of all fractions were tested using a 2,2-diphenyl-1-picrylhydrazyl (DPPH) assay. IC50 values (the amount of antioxidant needed to reduce 50% of DPPH) were then determined and values for the extracts ranged from 177 to 4458 μg/mL. Extracts prepared using polar solvents had significantly higher antioxidant capacities than others and may have clinical applications in any disease characterized by a chronic state of oxidative stress, such as sickle cell anemia. Further work will involve the assessment of these extracts in a sickle cell model of oxidative stress. PMID:29065510

  16. TYPE IC CHOLEDOCHAL CYST PRESENTING AN EXTRAHEPATAL CHOLESTASIS IN A 3 YEAR OLD BOY

    Directory of Open Access Journals (Sweden)

    Muhammad Reza

    2015-10-01

    Full Text Available Choledochal cyst is a rare congenital dilatation of the bile ducts, mostly diagnosed in childhood. Whenappropriate resection is not performed, cholangiocarcinoma may occur in a high incidence within thesecond decade of life. This report aims to present a rare case in experience of diagnosis and managementtype IC choledochal cyst in children. We present case of a 3-year-old boy who came with jaundice anditchy skin, abdominal pain, brownish urine, pales colored of stool. Abdominal ultrasonography andcomputed tomography scan revealed type IC choledochal cyst. Patient underwent complete cyst removalsurgery and bilioenteric anastomosis through Roux-en-y hepaticojejunostomy. Excision biopsy confirmedthe diagnosis of type IC choledochal cyst. Post surgical follow up shown good physical and laboratorycondition  and  there was no  recurrence  of  symptoms. Early  surgical  procedure  through Roux-en-yhepatojejunostomy, has been performed. Long  term  follow up also  facilities good prognostic  to  thepatient. [MEDICINA 2015;46:56-60].Kista  koledokus  adalah merupakan  penyakit  saluran  empedu  bawaan  yang  jarang  dijumpai  danbanyak terdiagnosis pada saat usia anak-anak. Tindakan berupa reseksi kista adalah yang terpentingdilakukan,  jika  tidak  segera  dilakukan  maka  dapat  meningkatkan  resiko  terjadinyacholangiocarcinoma dalam usia dekade kedua penderita dalam kehidupan. Tujuan kasus ini dilaporkanuntuk menggambarkan pengalaman dalam mendiagnosis dan tata  laksana kista koledokal tipe ICyang jarang pada anak-anak. Laporan kasus ini pada anak laki-laki berumur 3 tahun dengan keluhankulit tampak kuning dan gatal, nyeri perut, urin berwarna kecoklatan, tinja yang pucat. Ultrasonografidan CT  scan abdomen memperlihatkan adanya kista koledokus. Tindakan bedah  eksisi kista dananastomosis bilioenterik dengan menggunakan tehnik hepatojejunostomi Roux-en-y. Diagnosa kistakoledokus  tipe  IC  terkonfirmasi  saat

  17. Bronchodilator response of advanced lung function parameters depending on COPD severity

    Directory of Open Access Journals (Sweden)

    Jarenbäck L

    2016-11-01

    Full Text Available Linnea Jarenbäck,1 Göran Eriksson,1 Stefan Peterson,2 Jaro Ankerst,1 Leif Bjermer,1 Ellen Tufvesson1 1Respiratory Medicine and Allergology, Department of Clinical Sciences Lund, Lund University, 2Regional Cancer Center South, Skåne University Hospital, Lund, Sweden Background: COPD is defined as partly irreversible airflow obstruction. The response pattern of bronchodilators has not been followed in advanced lung function parameters. Purpose: The aim of this study was to investigate bronchodilator response pattern in advanced lung function parameters in a continuous fashion along forced expiratory volume in 1 second (FEV1 percent predicted (%p in COPD patients and controls. Patients and methods: Eighty-one smokers/ex-smokers (41 controls and 40 COPD performed spirometry, body plethysmography, impulse oscillometry and single-breath helium dilution carbon monoxide diffusion at baseline, after salbutamol inhalation and then after an additional inhalation of ipratropium. Results: Most pulmonary function parameters showed a linear increase in response to decreased FEV1%p. The subjects were divided into groups of FEV1%p <65 and >65, and the findings from continuous analysis were verified. The exceptions to this linear response were inspiratory capacity (IC, forced vital capacity (FVC, FEV1/FVC and expiratory resistance (Rex, which showed a segmented response relationship to FEV1%p. IC and FVC, with break points (BP of 57 and 58 FEV1%p respectively, showed no response above, but an incresed slope below the BP. In addition, in patients with FEV1%p <65 and >65, response of FEV1%p did not correlate to response of volume parameters. Conclusion: Response of several advanced lung function parameters differs depending on patients’ baseline FEV1%p, and specifically response of volume parameters is most pronounced in COPD patients with FEV1%p <65. Volume and resistance responses do not follow the flow response measured with FEV1 and may thus be used as a

  18. Body plethysmography in chronic obstructive pulmonary disease patients: A cross-sectional study

    Directory of Open Access Journals (Sweden)

    Yogesh Satyendra Gupta

    2018-01-01

    Full Text Available Background: Chronic obstructive pulmonary disease (COPD is the fourth most common cause of death in the world, for which smoking is a common cause. It is preferable to diagnose COPD at an earlier stage and to assess its progression so that mortality and morbidity of the disease could be reduced. Hence, we conducted this study to assess parameters of body plethysmography in Indian population where the data are lacking and to assess whether the use of body plethysmography can detect COPD earlier. Subjects and Methods: The study was approved by the Ethics Committee at B. J Government Medical College, Pune. In this comparative randomized cross-sectional study, healthy control subjects (CN, smokers without COPD diagnosis (SM who were smoking for more than 5 pack-years and smokers with COPD who were further classified depending upon GOLD criteria as mild COPD (C1, moderate COPD (C2, and severe COPD (C3 (n = 30 each group were considered. All the participants were males who gave written informed consent. Subject underwent routine spirometry (FEV1, FVC, FEV1/FVC, PEFR, and FEF25-75% along with body plethysmography where sGaweff, sGawtot, residual volume (RV, total lung capacity (TLC, and inspiratory capacity (IC were recorded. Statistical Analysis: The differences in lung function were compared between healthy controls and smokers and also between the three groups of COPD severity (GOLD guidelines employing univariate analysis of variance and Bonferroni's post hoc test. Results: Spirometry could not differentiate between smokers without COPD and healthy controls. However, three parameters on body plethysmography (IC, sGawtot, and sGaweff were sensitive enough to detect differences between smokers without COPD and healthy controls. Conclusion: Using body plethysmography, the vexed question troubling the clinician, which of the smokers progress to COPD and who do not before they develop irreversible changes can perhaps be answered if further large

  19. Relationships between Charpy impact shelf energies and upper shelf Ksub(IC) values for reactor pressure vessel steels

    International Nuclear Information System (INIS)

    Witt, F.J.

    1983-01-01

    Charpy shelf data and lower bound estimates of Ksub(IC) shelf data for the same steels and test temperatures are given. Included are some typical reactor pressure vessel steels as well as some less tough or degraded steels. The data were evaluated with shelf estimates of Ksub(IC) up to and exceeding 550 MPa√m. It is shown that the high shelf fracture toughness representative of tough reactor pressure vessel steels may be obtained from a knowledge of the Charpy shelf energies. The toughness transition may be obtained either by testing small fracture toughness specimens or by Charpy energy indexing. (U.K.)

  20. Large Eddy Simulations of Two-phase Turbulent Reactive Flows in IC Engines

    Science.gov (United States)

    Banaeizadeh, Araz; Schock, Harold; Jaberi, Farhad

    2008-11-01

    The two-phase filtered mass density function (FMDF) subgrid-scale (SGS) model is used for large-eddy simulation (LES) of turbulent spray combustion in internal combustion (IC) engines. The LES/FMDF is implemented via an efficient, hybrid numerical method. In this method, the filtered compressible Navier-Stokes equations in curvilinear coordinate systems are solved with a generalized, high-order, multi-block, compact differencing scheme. The spray and the FMDF are implemented with Lagrangian methods. The reliability and the consistency of the numerical methods are established for different IC engines and the complex interactions among mean and turbulent velocity fields, fuel droplets and combustion are shown to be well captured with the LES/FMDF. In both spark-ignition/direct-injection and diesel engines, the droplet size and velocity distributions are found to be modified by the unsteady, vortical motions generated by the incoming air during the intake stroke. In turn, the droplets are found to change the in-cylinder flow structure. In the spark-ignition engine, flame propagation is similar to the experiment. In the diesel engine, the maximum evaporated fuel concentration is near the cylinder wall where the flame starts, which is again consistent with the experiment.

  1. IC 3639 - A new bona fide Compton thick AGN unveiled by NuSTAR

    DEFF Research Database (Denmark)

    Boorman, Peter G.; Gandhi, P.; Alexander, D.

    2016-01-01

    We analyse high-quality NuSTAR observations of the local (z = 0.011) Seyfert 2 active galactic nucleus (AGN) IC 3639, in conjunction with archival Suzaku and Chandra data. This provides the first broadband X-ray spectral analysis of the source, spanning nearly two decades in energy (0.5 -30 keV)....

  2. Submicron InP DHBT technology for high-speed high-swing mixed-signal ICs

    DEFF Research Database (Denmark)

    Godin, Jean; Nodjiadjim, V.; Riet, Muriel

    2008-01-01

    We report on the development of a submicron InP DHBT technology, optimized for the fabrication of 50-GHz-clock mixed signal ICs. In-depth study of device geometry and structure has allowed to get the needed performances and yield. Special attention has been paid to critical thermal behavior. Vari...... applications of interest....

  3. The effect of ventilatory muscle training on respiratory function and capacity in ambulatory and bed-ridden patients with neuromuscular disease.

    Science.gov (United States)

    Gross, D; Meiner, Z

    1993-08-01

    Most patients with neuromuscular disease develop muscle weakness, including the ventilatory muscles leading to respiratory difficulty and, at times, respiratory insufficiency. We studied the effect of ventilatory muscle training on the ventilatory function and capacity of patients with various types of neuromuscular disease. The ambulatory patients were divided into three major groups. Group I (n = 6) patients with motor neuron disease (MND), such as amyotrophic latera sclerosis; Group II (n = 11) patients with myoneural junction disease (MNJ), such as myasthenia gravis and: Group III (n = 7) patients with muscle diseases such as progressive muscular disease. Patients were evaluated for their neuromuscular diagnosis and status of the disease. A complete physical examination and the various neuromuscular tests were performed. A complete respiratory evaluation was applied: pulmonary function tests (PFT), maximum inspiratory pressure (MIP). Patients then started ventilatory muscle training by resistive breathing, as a prophylactic treatment, for 10 min, three times daily, with a resistance which would induce fatigue. All tests were repeated every six weeks, and the results were as follow: forced vital capacity (FVC) changed from 38.8 +/- 12.3 to 53.2 +/- 9.6% (NS) of predicted value in group I, from 49.8 +/- 8.7 to 66.1 +/- 7.5% (p < 0.002) in group II, and from 47.0 +/- 7.5 to 53.3 +/- 7.6% (p < 0.04) in group III. Forced expiratory volume in one second (FEV1) was 34.8 +/- 11.0, 46.3 +/- 5, and 45.1 +/- 9% for the three groups, respectively, and did not change with training.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Relationships between diffusing capacity for carbon monoxide (D{sub L}CO), and quantitative computed tomography measurements and visual assessment for chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Nambu, Atsushi, E-mail: nambu-a@gray.plala.or.jp [Department of Radiology, National Jewish Health, 1400 Jackson Street, Denver, CO 80206 (United States); Department of Radiology, Teikyo University Mizonokuchi Hospital (Japan); Zach, Jordan, E-mail: ZachJ@NJHealth.org [Department of Radiology, National Jewish Health, 1400 Jackson Street, Denver, CO 80206 (United States); Schroeder, Joyce, E-mail: Joyce.schroeder@stanfordalumni.org [Department of Radiology, National Jewish Health, 1400 Jackson Street, Denver, CO 80206 (United States); Jin, Gong Yong, E-mail: gyjin@chonbuk.ac.kr [Department of Radiology, National Jewish Health, 1400 Jackson Street, Denver, CO 80206 (United States); Department of Radiology, Chonbuk National University Hospital (Korea, Republic of); Kim, Song Soo, E-mail: haneul88@hanmail.net [Department of Radiology, National Jewish Health, 1400 Jackson Street, Denver, CO 80206 (United States); Department of Radiology, Chungnam National Hospital, Chungnam National University School of Medicine (Korea, Republic of); Kim, Yu-IL, E-mail: kyionly@chonnam.ac.kr [Department of Medicine, National Jewish Health, Denver, CO (United States); Department of Internal Medicine, Chonnam National University Hospital, Gwangju (Korea, Republic of); Schnell, Christina, E-mail: SchnellC@NJHealth.org [Department of Medicine, National Jewish Health, Denver, CO (United States); Bowler, Russell, E-mail: BowlerR@NJHealth.org [Division of Pulmonary Medicine, Department of Medicine, National Jewish Health (United States); Lynch, David A., E-mail: LynchD@NJHealth.org [Department of Radiology, National Jewish Health, 1400 Jackson Street, Denver, CO 80206 (United States)

    2015-05-15

    Highlights: • Quantitative CT measurements significantly correlated with D{sub L}CO/V{sub A}. • 15{sup th} percentile HU had the strongest correlation with D{sub L}CO/V{sub A}. • Visual scoring of emphysema had independent significant correlations with D{sub L}CO/V{sub A}. - Abstract: Purpose: To evaluate the relationships between D{sub L}CO, and Quantitative CT (QCT) measurements and visual assessment of pulmonary emphysema and to test the relative roles of visual and quantitative assessment of emphysema. Materials and methods: The subjects included 199 current and former cigarette smokers from the COPDGene cohort who underwent inspiratory and expiratory CT and also had diffusing capacity for carbon monoxide corrected for alveolar volume (D{sub L}CO/V{sub A}). Quantitative CT measurements included % low attenuation areas (%LAA−950ins = voxels ≤−950 Hounsfield unit (HU), % LAA{sub −910ins}, and % LAA{sub −856ins}), mean CT attenuation and 15th percentile HU value on inspiratory CT, and %LAA{sub −856exp} (voxels ≤−856 HU on expiratory CT). The extent of emphysema was visually assessed using a 5-point grading system. Univariate and multiple variable linear regression analyses were employed to evaluate the correlations between D{sub L}CO/V{sub A} and QCT parameters and visual extent of emphysema. Results: The D{sub L}CO/V{sub A} correlated most strongly with 15th percentile HU (R{sup 2} = 0.440, p < 0.001) closely followed by % LAA{sub −950ins} (R{sup 2} = 0.417, p < 0.001) and visual extent of emphysema (R{sup 2} = 0.411, p < 0.001). Multiple variable analysis showed that visual extent of emphysema and 15th percentile HU were independent significant predictors of D{sub L}CO/V{sub A} at an R{sup 2} of 0.599. Conclusions: 15th percentile HU seems the best parameter to represent the respiratory condition of COPD. Visual and Quantitative CT assessment of emphysema provide complementary information to QCT analysis.

  5. DISCOVERY OF THE BROAD-LINED TYPE Ic SN 2013cq ASSOCIATED WITH THE VERY ENERGETIC GRB 130427A

    Energy Technology Data Exchange (ETDEWEB)

    Xu, D.; Krühler, T.; Hjorth, J.; Malesani, D.; Fynbo, J. P. U.; Watson, D. J.; Geier, S. [Dark Cosmology Centre, Niels Bohr Institute, University of Copenhagen, Juliane Maries Vej 30, DK-2100 København Ø (Denmark); De Ugarte Postigo, A.; Thöne, C. C.; Sánchez-Ramírez, R. [Instituto de Astrofísica de Andalucía, CSIC, Glorieta de la Astronomía s/n, E-18008 Granada (Spain); Leloudas, G. [The Oskar Klein Centre, Department of Physics, Stockholm University, AlbaNova, SE-10691 Stockholm (Sweden); Cano, Z.; Jakobsson, P. [Centre for Astrophysics and Cosmology, Science Institute, University of Iceland, Dunhagi 5, IS-107 Reykjavik (Iceland); Schulze, S. [Departamento de Astronomía y Astrofísica, Pontificia Universidad Católica de Chile, Casilla 306, Santiago 22 (Chile); Kaper, L. [Astronomical Institute Anton Pannekoek, University of Amsterdam, Science Park 904, NL-1098 XH Amsterdam (Netherlands); Sollerman, J. [The Oskar Klein Centre, Department of Astronomy, Stockholm University, AlbaNova, SE-10691 Stockholm (Sweden); Cabrera-Lavers, A. [Instituto de Astrofísica de Canarias, E-38205 La Laguna, Tenerife (Spain); Cao, C. [Department of Space Science and Physics, Shandong University at Weihai, Weihai, Shandong 264209 (China); Covino, S. [INAF/Brera Astronomical Observatory, via Bianchi 46, I-23807 Merate (Italy); Flores, H., E-mail: dong@dark-cosmology.dk [Laboratoire Galaxies Etoiles Physique et Instrumentation, Observatoire de Paris, 5 place Jules Janssen, F-92195 Meudon (France); and others

    2013-10-20

    Long-duration gamma-ray bursts (GRBs) at z < 1 are found in most cases to be accompanied by bright, broad-lined Type Ic supernovae (SNe Ic-BL). The highest-energy GRBs are mostly located at higher redshifts, where the associated SNe are hard to detect observationally. Here, we present early and late observations of the optical counterpart of the very energetic GRB 130427A. Despite its moderate redshift, z = 0.3399 ± 0.0002, GRB 130427A is at the high end of the GRB energy distribution, with an isotropic-equivalent energy release of E{sub iso} ∼ 9.6 × 10{sup 53} erg, more than an order of magnitude more energetic than other GRBs with spectroscopically confirmed SNe. In our dense photometric monitoring, we detect excess flux in the host-subtracted r-band light curve, consistent with that expected from an emerging SN, ∼0.2 mag fainter than the prototypical SN 1998bw. A spectrum obtained around the time of the SN peak (16.7 days after the GRB) reveals broad undulations typical of SNe Ic-BL, confirming the presence of an SN, designated SN 2013cq. The spectral shape and early peak time are similar to those of the high expansion velocity SN 2010bh associated with GRB 100316D. Our findings demonstrate that high-energy, long-duration GRBs, commonly detected at high redshift, can also be associated with SNe Ic-BL, pointing to a common progenitor mechanism.

  6. Xanthine oxidase inhibitors from Archidendron clypearia (Jack.) I.C. Nielsen: Results from systematic screening of Vietnamese medicinal plants

    Institute of Scientific and Technical Information of China (English)

    Nguyen Thuy Duong; Pham Duc Vinh; Phuong Thien Thuong; Nguyen Thi Hoai; Le Nguyen Thanh; Tran The Bach; Nguyen Hai Nam; Nguyen Hoang Anh

    2017-01-01

    Objective:To screen Vietnamese medicinal plants for xanthine oxidase (XO) inhibitory activity and to isolate XO inhibitor(s) from the most active plant.Methods: The plants materials were extracted by methanol. The active plant materials were fractionated using different organic solvents, includingn-hexane, ethyl acetate, andn-butanol. Bioassay-guided fractionation and column chromatography were used to isolate compounds. The compounds structures were elucidated by analysis of spectroscopic data, including IR, MS, and NMR. Results:Three hundreds and eleven methanol extracts (CME) belonging to 301 Vietnamese herbs were screened for XO inhibitory activity. Among these plants, 57 extracts displayed XO inhibitory activity at 100 μg/mL with inhibition rates of over 50%. The extracts of Archidendron clypearia,Smilax poilanei,Linociera ramiflora and Passiflora foetida exhibited the greatest potency with IC50 values below 30 μg/mL. Chemical study performed on the extract ofArchidendron clypearia resulted in the isolation of six compounds, including 1-octacosanol, docosenoic acid, daucosterol, methyl gallate, quercitrin and (?)-7-O-galloyltricetiflavan. The compound (?)-7-O-galloyltricetiflavan showed the most potent XO inhibitory activity with an IC50 value of 25.5 μmol/L.Conclusions:From this investigation, four Vietnamese medicinal plants were identified to have XO inhibitory effects with IC50 values of the methanol extracts below 30 μg/mL. Compound (?)-7-O-galloyltricetiflavan was identified as an XO inhibitor from Archidendron clypearia with IC50 value of 25.5 μmol/L.

  7. Desain dan Implementasi Virtual Laboratory Materi Osilator Analog berbasis IC OP-AMP

    Directory of Open Access Journals (Sweden)

    SYIFAUL FUADA

    2016-08-01

    Full Text Available ABSTRAK Laboratorium virtual merupakan salah satu platform laboratorium modern yang dapat mendukung kegiatan praktikum yang berjalan secara tradisional (Hand-on Laboratory.Penelitian ini bertujuan untuk mendesain dan mengimplementasikan Virtual Laboratory pada materi pembangkit sinyal dengan subtopik: Wien Bridge sebagai osilator RC, Hartley dan Colpitts sebagai osilator LC dan Astable Multivibrator sebagai osilator relaksasi,yang dibangun berbasis IC Operational Amplifier (OP-AMP.Jenis penelitian ini merupakan R&Dyang terdiri dari enam tahapan, yaitu:konsep, desain, pengumpulan bahan, pembuatan, pengujian dan pendistribusian. Aplikasi perangkat lunak berbasis dekstop ini telah diuji secara fungsional dengan 6 (enam aspek parameter yakni:uji polaritas kapastor; uji wiring; uji mode frekuensi dan mode perioda pada alat ukur frequency generator; uji specific decission pada trainer kit osilator hartley dan colpitts; uji kesesuaian antara frekuensi ouput dari masing-masing osilator dengan perhitungan teorema dan hasil percobaan sesungguhnya; dan uji kualitas media. Hasil secara keseluruhan telah sesuai dengan ekspektasi didalam story board. Kata kunci: IC OP-AMP, Osilator analog, Laboratorium virtual ABSTRACT The Virtual Laboratory is as one of modern laboratory platform which able to supportthe hand-on worklab. The goal of this research are for designing and implementing a Virtual Laboratory of signal generator material with subtopics i.e. the Wien Bridge as an RC oscillator, the Hartley and Colpitts as LC oscillator and the astable multivibrator as relaxation oscillator which assembled based on Operational Amplifier Integrated Circuit (OP-AMP.This research is R&D type which consists of six stages, i.e. concept, design, materials collection, assembling, testing and distribution. This desktop-based software application has been functionally tested with six aspect of parameters such as: capacitor polarity testing; wiring testing; testing of frequency

  8. Increase in complement iC3b is associated with anti-inflammatory cytokine expression during late pregnancy in mice.

    Directory of Open Access Journals (Sweden)

    Keigo Nakamura

    Full Text Available Immunological tolerance between fetal allograft and mother is crucial for pregnancy establishment and maintenance; however, these mechanisms particularly those during the latter part of pregnancy have not been definitively elucidated. The aim of this study was to examine the presence and potential function of innate immunity characteristic to the middle to late pregnancy. We first characterized up-regulated proteins in decidua from day 11 pregnant (P11 mice using 2D-PAGE, followed by MALDI-TOF/MS analysis. These analyses identified increased complement component 3 (C3 and its derivatives in P11 decidua. We then found that in the decidual tissues, C3 mRNA increased on P15 and remained high on P19. C3 is converted to C3b and then iC3b by complement component factor I (Cfi and complement receptor 1-like protein (Crry, both of which were present in P19 placentas. In addition, iC3b proteins and its receptor CR3 (Cd11b/Cd18 in decidual and placental tissues increased toward the latter phase of pregnancy. Moreover, CR3 subunit CD11b protein was predominantly localized to spongiotrophoblast layer in the P19 placenta. Because iC3b is known to induce anti-inflammatory cytokine production, the analysis was extended to examine changes in pro- and anti-inflammatory cytokines, Il12, Il10, and Tgfb1. Il12 expression decreased in P15 and P19 placenta, while high mRNA expression of Il10 and Tgfb1 was found in P19 placental tissues. Furthermore, placental Il10 and Tgfb1 mRNAs were down-regulated when pregnant mice were treated with an anti-C3 antibody, detecting C3, C3b and iC3b. These results indicated that C3 derivatives, in particular, iC3b and its receptor CR3 were up-regulated at the fetal-maternal interface, and suggest that iC3b may regulate the placental expression of anti-inflammatory cytokines, IL10 and TGFB1, during the latter phase of pregnancy.

  9. ENN-ICS - quality assurance and online evaluation of a multilingual learning management system for sleep medicine

    Directory of Open Access Journals (Sweden)

    Knobl, Brigitte

    2006-11-01

    Full Text Available With the development and implementation of a multilingual interactive communication system the e-health project ENN-ICS, funded by the European Union, aims at the improvement of health care in Europe. The field of application is sleep physiology and sleep medicine. ENN-ICS Centre offers direct access to medical information for multiple users, i.e. health authorities, health care professionals, patients and citizen. Using XML technologies the new web based network integrates advanced e-learning and e-publishing methods for the training of healthcare professionals. Editorial and distributive processes are supported by customized central editorial, content management and learning management systems (CMS, LMS. ENN-ICS e-health services are evaluated by selected user groups in North, Middle and Southern Europe using reliable and scientifically accepted validation instruments. The compliance with essential quality requirements and criteria is tested and verified by using adapted online questionnaires based on the DISCERN questionnaire for evaluating patient information, on the HON principles for evaluating health-related websites and on the GMDS catalogue of quality criteria for electronic publications in medicine. The system architecture and its exemplary applications can be used as a model for future e-health services dealing with neurological and other medical topics.

  10. Diaphragmatic thickness ratio (inspiratory/expiratory) as a diagnostic method of diaphragmatic palsy associated with interescalene block.

    Science.gov (United States)

    López Escárraga, V M; Dubos España, K; Castillo Bustos, R H; Peidró, L; Sastre, S; Sala-Blanch, X

    2018-02-01

    Diaphragmatic paralysis is a side-effect associated with interscalene block. Thickness index of the diaphragm muscle (inspiratory thickness/expiratory thickness) obtained by ultrasound has recently been introduced in clinical practice for diagnosis of diaphragm muscle atrophy. Our objective was to evaluate this index for the diagnosis of acute phrenic paresis associated with interscalene block. We designed an observational study in 22 patients scheduled for shoulder arthroscopy. Spirometry was performed (criteria of phrenic paresis was a decrease in FVC and FEV1 ≥20%). Ultrasound apposition zone was assessed in anterior axillary line and diaphragmatic displacement was evaluated on inspiration and expiration (number of intercostal spaces; phrenic paresis considered a reduction ≥25%) and thickness of the diaphragm muscle (a phrenic paresis was considered an index block at C5-C6 with 20ml of 0.5% ropivacaine. Twenty-one patients (95%) presented phrenic nerve block according to one or more of the methods used. One patient did not show any symptoms or signs suggestive of phrenic paralysis and was excluded. All the patients presented phrenic paresis based on the diaphragmatic thickness index, with the pre-block index being 1.8±0.5 and post-block of 1.05±0.06 (Pblock (from 1.9±0.5 intercostal spaces to 0.5±0.3; Pblock. This index does not require a baseline pre-assessment. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Comparison between dominant NB and dominant IC heated ELMy H-mode discharges in JET

    NARCIS (Netherlands)

    Versloot, T.W.; Sartori, R.; de Vries, P.C.; et al, [No Value

    2011-01-01

    Abstract The experiment described in this paper is aimed at characterization of ELMy H-mode discharges with varying momentum input, rotation, power deposition profiles and ion to electron heating ratio obtained by varying the proportion between ion cyclotron (IC) and neutral beam (NB) heating. The

  12. Comparison between dominant NB and dominant IC heated ELMy H-mode discharges in JET

    NARCIS (Netherlands)

    Versloot, T. W.; Sartori, R.; Rimini, F.; de Vries, P. C.; Saibene, G.; Parail, V.; Beurskens, M. N. A.; Boboc, A.; Budny, R.; Crombe, K.; de la Luna, E.; Durodie, F.; Eich, T.; Giroud, C.; Kiptily, V.; Johnson, T.; Mantica, P.; Mayoral, M. L.; McDonald, D. C.; Monakhov, I.; Nave, M. F. F.; Voitsekhovitch, I.; Zastrow, K. D.

    2011-01-01

    The experiment described in this paper is aimed at characterization of ELMy H-mode discharges with varying momentum input, rotation, power deposition profiles and ion to electron heating ratio obtained by varying the proportion between ion cyclotron (IC) and neutral beam (NB) heating. The motivation

  13. Interstellar Lithium and Rubidium in the Diffuse Gas Near IC 443

    Science.gov (United States)

    Ritchey, Adam M.; Taylor, C. J.; Federman, S. R.; Lambert, D. L.

    2011-01-01

    We present an analysis of interstellar lithium and rubidium from observations made with the Hobby-Eberly Telescope at McDonald Observatory of the Li I λ6707 and Rb I λ7800 absorption lines along four lines of sight through the supernova remnant IC 443. The observations probe interstellar material polluted by the ejecta of a core-collapse (Type II) supernova and can thus be used to constrain the contribution from massive stars to the synthesis of lithium and rubidium. Production of 7Li is expected to occur through neutrino spallation in the helium and carbon shells of the progenitor star during the terminal supernova explosion, while both 6Li and 7Li are synthesized via spallation and fusion reactions involving cosmic rays accelerated by the remnant. Gamma-ray emission from IC 443 provides strong evidence for the interaction of accelerated cosmic rays with the ambient atomic and molecular gas. Rubidium is also produced by massive stars through the weak s-process in the He- and C-burning shells and the r-process during core collapse. We examine interstellar 7Li/6Li isotope ratios as well as Li/K and Rb/K ratios along each line of sight, and discuss the implications of our results in the context of nucleosynthesis associated with Type II supernovae.

  14. Changed of the working capacity of CMOS integrated circuits under ionizing radiations effect of low and high dose rate; Izmeneniya rabotosposobnosti KMOP integral`nykh mikroskhem pri vozdejstvii ioniziruyushchikh izluchenij s nizkoj i vysokoj intensivnost`yu

    Energy Technology Data Exchange (ETDEWEB)

    Bogatyrev, Yu V; Korshunov, F P

    1994-12-31

    Results of experimental investigations into the working capacity of different types of integrated CMOS circuits under effect of electron and gamma radiation are presented. Methods for evaluating IC CMOS under low irradiation intensity using the microcircuit testing under hugh intensity or at increased temperature with regard to the processes of parameter reconstruction after irradiation are proposed.

  15. A revolutionary concept to improve the efficiency of IC antennas

    Energy Technology Data Exchange (ETDEWEB)

    Milanesio, D.; Maggiora, R. [Politecnico di Torino, Dipartimento di Elettronica e Telecomunicazioni (DET), Torino (Italy)

    2014-02-12

    The successful design of an Ion Cyclotron (IC) antenna mainly relies on the capability of coupling high power to the plasma (MW), feature that is currently reached by allowing rather high voltages (tens of kV) on the unavoidable unmatched part of the feeding lines. This requirement is often responsible of arcs along the transmission lines and other unwanted phenomena that considerably limit the usage of IC launchers. In this work, we suggest and describe a revolutionary approach based on high impedance surfaces, which allows to increase the antenna radiation efficiency and, hence, to highly reduce the imposed voltages to couple the same level of power to the plasma. High-impedance surfaces are periodic metallic structures (patches) displaced usually on top of a dielectric substrate and grounded by means of vertical posts usually embedded inside a dielectric, in a mushroom-like shape. In terms of working properties, high impedance surfaces are electrically thin in-phase reflectors, i.e. they present a high impedance, within a given frequency band, such that the image currents are in-phase with the currents of the antenna itself, thus determining a significant efficiency increase. While the usual design of a high impedance surface requires the presence of a dielectric layer, some alternative solutions can be realized in vacuum, taking advantage of double layers ofmetallic patches. After an introductory part on the properties of high impedance surfaces, this work documents both their design by means of numerical codes and their implementation on a scaled mock-up.

  16. IN-SYNC. III. THE DYNAMICAL STATE OF IC 348—A SUPER-VIRIAL VELOCITY DISPERSION AND A PUZZLING SIGN OF CONVERGENCE

    International Nuclear Information System (INIS)

    Cottaar, Michiel; Meyer, Michael R.; Covey, Kevin R.; Foster, Jonathan B.; Tan, Jonathan C.; Rio, Nicola da; Nidever, David L.; Chojnowski, S. Drew; Majewski, Steve; Skrutskie, Michael F.; Wilson, John C.; Zasowski, Gail; Flaherty, Kevin M.; Frinchaboy, Peter M.

    2015-01-01

    Most field stars will have encountered the highest stellar density and hence the largest number of interactions in their birth environment. Yet the stellar dynamics during this crucial phase are poorly understood. Here we analyze the radial velocities measured for 152 out of 380 observed stars in the 2–6 Myr old star cluster IC 348 as part of the SDSS-III APOGEE. The radial velocity distribution of these stars is fitted with one or two Gaussians, convolved with the measurement uncertainties including binary orbital motions. Including a second Gaussian improves the fit; the high-velocity outliers that are best fit by this second component may either (1) be contaminants from the nearby Perseus OB2 association, (2) be a halo of ejected or dispersing stars from IC 348, or (3) reflect that IC 348 has not relaxed to a Gaussian velocity distribution. We measure a velocity dispersion for IC 348 of 0.72 ± 0.07 km s −1 (or 0.64 ± 0.08 km s −1 if two Gaussians are fitted), which implies a supervirial state, unless the gas contributes more to the gravitational potential than expected. No evidence is found for a dependence of this velocity dispersion on distance from the cluster center or stellar mass. We also find that stars with lower extinction (in the front of the cloud) tend to be redshifted compared with stars with somewhat higher extinction (toward the back of the cloud). This data suggest that the stars in IC 348 are converging along the line of sight. We show that this correlation between radial velocity and extinction is unlikely to be spuriously caused by the small cluster rotation of 0.024 ± 0.013 km s −1 arcmin −1 or by correlations between the radial velocities of neighboring stars. This signature, if confirmed, will be the first detection of line of sight convergence in a star cluster. Possible scenarios for reconciling this convergence with IC 348's observed supervirial state include: (a) the cluster is fluctuating around a new virial

  17. Pengaruh Pengungkapan Intellectual Capital (IC dan Economic Value Added (EVA terhadap Harga Saham Perusahaan Manufaktur yang terdaftar di BEI

    Directory of Open Access Journals (Sweden)

    Achmad Fauzi

    2015-07-01

    Full Text Available This study aims at finding out if The Influence of Intellectual Capital (ICand Economic Value Added (EVA on Stock Price of Manufacturing Companies listed on the Indonesia Stock Exchange (BEI in 2012. The hypothesis of this study is : There is Influence of Intellectual Capital (IC and Economic Value Added (EVA on Stock Price of Manufacturing Company listed on the Indonesia Stock Exchange (BEI in 2012. The method used is the author of the survey method with a quantitative approach . This study population is the entire manufacturing companies listed on the Stock Exchange in 2012 his sampling technique is random sampling as many as 36 samples .. Correlation Coefficient significance test ( Test A of 0.512 , indicating that there is a middle relationship between IC and EVA on Stock Price. The results of the coefficient of determination ( R2 Test stated that R2 is 0.262 or 26.2% . This shows that the percentage contribution of the effect of independent variables ( IC and EVA on the dependent variable ( stock price of 26.2 % . Or variations of the independent variables used in the model ( IC and EVA are able to explain 26.2% of variation in the dependent variable ( stock price . While the remaining 73.8 % are influenced or explained by other variables not included in this research model .

  18. A reuse-based framework for the design of analog and mixed-signal ICs

    Science.gov (United States)

    Castro-Lopez, Rafael; Fernandez, Francisco V.; Rodriguez Vazquez, Angel

    2005-06-01

    Despite the spectacular breakthroughs of the semiconductor industry, the ability to design integrated circuits (ICs) under stringent time-to-market (TTM) requirements is lagging behind integration capacity, so far keeping pace with still valid Moore"s Law. The resulting gap is threatening with slowing down such a phenomenal growth. The design community believes that it is only by means of powerful CAD tools and design methodologies - and, possibly, a design paradigm shift - that this design gap can be bridged. In this sense, reuse-based design is seen as a promising solution, and concepts such as IP Block, Virtual Component, and Design Reuse have become commonplace thanks to the significant advances in the digital arena. Unfortunately, the very nature of analog and mixed-signal (AMS) design has hindered a similar level of consensus and development. This paper presents a framework for the reuse-based design of AMS circuits. The framework is founded on three key elements: (1) a CAD-supported hierarchical design flow that facilitates the incorporation of AMS reusable blocks, reduces the overall design time, and expedites the management of increasing AMS design complexity; (2) a complete, clear definition of the AMS reusable block, structured into three separate facets or views: the behavioral, structural, and layout facets, the two first for top-down electrical synthesis and bottom-up verification, the latter used during bottom-up physical synthesis; (3) the design for reusability set of tools, methods, and guidelines that, relying on intensive parameterization as well as on design knowledge capture and encapsulation, allows to produce fully reusable AMS blocks. A case study and a functional silicon prototype demonstrate the validity of the paper"s proposals.

  19. Clock- and data-recovery IC with demultiplexer for a 2.5 Gb/s ATM physical layer controller

    DEFF Research Database (Denmark)

    Hansen, Flemming; Salama, C.A.T.

    1996-01-01

    A Clock- and Data-Recovery (CDR) IC for a Physical Layer Controller in an Asynchronous Transfer Mode (ATM) system operating at a bit rate of 2.488 Gb/s is presented. The circuit was designed and fabricated in a 0.8 μm BiCMOS process featuring 13 GHz fT bipolar transistors. Clock-recovery is accom......A Clock- and Data-Recovery (CDR) IC for a Physical Layer Controller in an Asynchronous Transfer Mode (ATM) system operating at a bit rate of 2.488 Gb/s is presented. The circuit was designed and fabricated in a 0.8 μm BiCMOS process featuring 13 GHz fT bipolar transistors. Clock...

  20. 3-D ICs as a Platform for IoT Devices

    Science.gov (United States)

    2017-03-01

    are both naturally reduced in 3-D ICs. I. INTRODUCTION The Internet of Things (IoT) is a novel computing paradigm based on connecting physical devices...cost and high transparency [6]. PET is used as the substrate of p-i-n type solar cells and is compatible with the traditional deposition process of solar ...10 138 3.42 to 3.48 130 to 185 2.6 400 to 1,060memory Solar cells Polyethylene 1 · 1016 0.2 1.58 to 1.64 2 to 2.7 3.9 400 to 1,600Terephthalate (PET