WorldWideScience

Sample records for inspections methods manual

  1. Savannah River Plant waste tank inspection manual

    International Nuclear Information System (INIS)

    McNatt, F.G.

    1979-01-01

    This manual is to aid in making visual and photographic inspections and steel thickness measurements of Building 241-F and -H underground waste storage tanks. It describes the inspection program, the storage tanks, the equipment and techniques used and the results of their application, and the inspection recordkeeping methods

  2. Construction inspection manual of procedures

    Science.gov (United States)

    2009-01-01

    This manual provides highway construction personnel with relevant, practical information in order to perform accurate inspections and provide relevant construction procedural information for the various roadway and structures items of work. It is the...

  3. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 7, 0.07 Conveying

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    System information is given for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; and system work breakdown structure. Deficiency standards and inspection methods are presented for elevators and special conveyors.

  4. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 2, 0.02 Substructure

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    System information is given for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. System assembly/component deficiencies and inspection methods are given for slabs-on-grade, columns, and column fireproofing.

  5. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 3, 0.03 Superstructure

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented on asset determinant factor/CAS profile codes/CAS cost process; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are presented for beams; pre-engineered building systems; floors; roof structure; stairs; and fireproofing.

  6. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 1, 0.01 Foundations and footings

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are given for footings - spread/strip/grade beams; foundation walls; foundation dampproofing/waterproofing; excavation/backfill/ and piles & caissons.

  7. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 12, 0.12 Sitework

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are given for utility distribution systems, central heating, central cooling, electrical, utility support structures, paving roadways/walkways, and tunnels.

  8. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 11, 0.11 Specialty systems

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are presented for canopies; loading dock systems; tanks; domes (bulk storage, metal framing); louvers & vents; access floors; integrated ceilings; and mezzanine structures.

  9. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 6, 0.06 Interior construction

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are presented for conventional and specialty partitions, toilet partitions & accessories, interior doors, paint finishes/coatings/ wall covering systems; floor finishing systems; and ceiling systems.

  10. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 5, 0.05 Roofing

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; and system work breakdown structure. Deficiency standards and inspection methods are presented for built-up membrane; single- ply membrane; metal roofing systems; coated foam membrane; shingles; tiles; parapets; roof drainage system; roof specialties; and skylights.

  11. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 8, 0.08 Mechanical, Book 1

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    System information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet too & material listing; testing methods; inspection frequency; standard system design life tables; and system work breakdown structure. Deficiency standards are given for plumbing, fire protection, heating, cooling, and special (drinking water cooling systems).

  12. Detecting accuracy of flaws by manual and automatic ultrasonic inspections

    International Nuclear Information System (INIS)

    Iida, K.

    1988-01-01

    As the final stage work in the nine year project on proving tests of the ultrasonic inspection technique applied to the ISI of LWR plants, automatic ultrasonic inspection tests were carried out on EDM notches, surface fatigue cracks, weld defects and stress corrosion cracks, which were deliberately introduced in full size structural components simulating a 1,100 MWe BWR. Investigated items are the performance of a newly assembled automatic inspection apparatus, detection limit of flaws, detection resolution of adjacent collinear or parallel EDM notches, detection reproducibility and detection accuracy. The manual ultrasonic inspection of the same flaws as inspected by the automatic ultrasonic inspection was also carried out in order to have comparative data. This paper reports how it was confirmed that the automatic ultrasonic inspection is much superior to the manual inspection in the flaw detection rate and in the detection reproducibility

  13. The radioprotection inspection manual for odontologic X-rays equipment

    International Nuclear Information System (INIS)

    Almeida, C.D. de.

    1988-01-01

    The inspection manual for odontologic X-ray, using films and thermoluminescent dosemeters are showed, decreasing the time of exposition by some recommendation. Some calculations are also cited, for decrease the exposure time, for filtrating the equipment and for a radiometric survey. (C.G.C.) [pt

  14. Radioanalytical methods manual

    International Nuclear Information System (INIS)

    Chiu, N.W.; Dean, J.R.

    1986-01-01

    This Radioanalytical Methods manual is comprised of 12 chapters. It includes a review of the pertinent literature up to the end of 1982 pertaining to the measurement of the radioactive species listed under the terms of the contract. Included is methodology recommended for the decompositions of soils, tailings, ores, biological samples and air filters. Detailed analytical methodology for the measurement of gross alpha, gross beta, gross gamma, uranium, radium-226, radium-228, lead-210, thorium-232, thorium-230, thorium-228, total thorium, radon-222, radon-220 and radon-219 is presented

  15. Inspection Methods in Programming.

    Science.gov (United States)

    1981-06-01

    Counting is a a specialization of Iterative-generation in which the generating function is Oneplus ) Waters’ second category of plan building method...is Oneplus and the initial input is 1. 0 I 180 CHAPTER NINE -ta a acio f igr9-.IeaieGnrtoPln 7 -7 STEADY STATE PLANS 181 TemporalPlan counting...specializalion iterative-generation roles .action(afu nction) ,tail(counting) conslraints .action.op = oneplus A .action.input = 1 The lItcrative-application

  16. Inspection of internal tank welds using the ACFM inspection method

    International Nuclear Information System (INIS)

    Topp, D.A.; Lugg, M.C.

    2009-01-01

    The paper describes recent developments of the ACFM technique and describes several case studies where ACFM has been used to inspect the internal plate welds on large steel storage tanks in refineries. For weld inspection, conventional methods such as magnetic particle inspection or vacuum box testing are generally used. This paper presents comparisons of the results from ACFM with those from the conventional methods, from which conclusions are drawn as to the benefits this technique offers in terms of cost, time savings and inspection reliability. (author)

  17. 33 CFR 157.150 - Crude Oil Washing Operations and Equipment Manual: Recording information after inspections.

    Science.gov (United States)

    2010-07-01

    ... Equipment Manual: Recording information after inspections. 157.150 Section 157.150 Navigation and Navigable... Vessels Inspections § 157.150 Crude Oil Washing Operations and Equipment Manual: Recording information... machines. (2) Revolutions, number of cycles, and length of cycles of each COW machine. (3) Pressure and...

  18. User interface inspection methods a user-centered design method

    CERN Document Server

    Wilson, Chauncey

    2014-01-01

    User Interface Inspection Methods succinctly covers five inspection methods: heuristic evaluation, perspective-based user interface inspection, cognitive walkthrough, pluralistic walkthrough, and formal usability inspections. Heuristic evaluation is perhaps the best-known inspection method, requiring a group of evaluators to review a product against a set of general principles. The perspective-based user interface inspection is based on the principle that different perspectives will find different problems in a user interface. In the related persona-based inspection, colleagues assume the

  19. Manual phased arrays for weld inspections using North American codes

    International Nuclear Information System (INIS)

    Moles, Michael

    2008-01-01

    Phased arrays are primarily a method of generating and receiving ultrasound, not a new technology. In addition, the physics of ultrasound generated by phased arrays is identical to that from conventional monocrystals. Not surprisingly, all the major North American (and some European) codes accept phased arrays, either explicitly or implicitly. However, the technique and procedures needs to be proven, typically by a Performance Demonstration. The ASME (AmeicanSociety for Mechanical Engineers) Section V and API RP2X explicitly accept phased arrays. Three ASME code cases have been written specifically fo manual phased array: Code Cases 2541. 2557 and 2558. Over and above the general requirements of Article 4, these Code Cases require full waveform calibration. This is echoed in ASTM E-2491, a Standard Guide for setting up phased arrays. In addition. details such as focusing and reporting are addressed. The American Petroleum Institute QUTE procedure did not need any modifications to be compatible with manual phased arrays. The American Welding Society (AWS) Structural Welding Code D1.1 implicitly accepts phased arrays. New technologies such as phased arrays can be proven using Annex K. Nonetheless, a manual phased array unit using the standard AWS probe and displaying 45, 60 and 70degrees waveforms would be acceptable for D1.1 a s is . Overall, most major North American codes accept phased arrays, however, the technique and procedures must be proven, often using a Performance Demonstration. (author)

  20. Exercise manual for the Augmented Computer Exercise for Inspection Training (ACE-IT) software

    Energy Technology Data Exchange (ETDEWEB)

    Dobranich, P.R.; Widney, T.W.; Goolsby, P.T. [Sandia National Labs., Albuquerque, NM (United States). Cooperative Monitoring Center and Regional Security; Nelson, J.D.; Evanko, D.A. [Ogden Environmental and Energy Services, Inc., Albuquerque, NM (United States)

    1997-09-01

    The on-site inspection provisions in many current and proposed arms control agreements require extensive preparation and training on the part of both the Inspected Party and the Inspection Team. Current training techniques include table-top inspections and practice inspections. The Augmented Computer Exercise for Inspection Training (ACE-IT), an interactive computer training tool, increases the utility of table-top inspections. ACE-IT has been designed to provide training for a hypothetical challenge inspection under the Chemical Weapons Convention (CWC); however, this training tool can be modified for other inspection regimes. Although ACE-IT provides training from notification of an inspection through post-inspection activities, the primary emphasis of ACE-IT is in the inspection itself--particularly with the concept of managed access. ACE-IT also demonstrates how inspection provisions impact compliance determination and the protection of sensitive information. The Exercise Manual supplements the ACE-IT software by providing general information on on-site inspections and detailed information for the CWC challenge inspection exercise. The detailed information includes the pre-inspection briefing, maps, list of sensitive items, medical records, and shipping records.

  1. Transferring manual ultrasonic inspection procedures - results of a pilot study

    International Nuclear Information System (INIS)

    Anderson, M.; Taylor, T.; Kadenko, I.

    2002-01-01

    Results of a manual ultrasonic pilot study for NDE specialists at RBMK nuclear reactor sites are presented. Probabilities of detection and false calls, using two different grading criteria, are estimated. Analyses of performance parameters lead to conclusions regarding attributes for improved test discrimination capabilities. (orig.)

  2. Emerging nondestructive inspection methods for aging aircraft

    Energy Technology Data Exchange (ETDEWEB)

    Beattie, A; Dahlke, L; Gieske, J [and others

    1994-01-01

    This report identifies and describes emerging nondestructive inspection (NDI) methods that can potentially be used to inspect commercial transport and commuter aircraft for structural damage. The nine categories of emerging NDI techniques are: acoustic emission, x-ray computed tomography, backscatter radiation, reverse geometry x-ray, advanced electromagnetics, including magnetooptic imaging and advanced eddy current techniques, coherent optics, advanced ultrasonics, advanced visual, and infrared thermography. The physical principles, generalized performance characteristics, and typical applications associated with each method are described. In addition, aircraft inspection applications are discussed along with the associated technical considerations. Finally, the status of each technique is presented, with a discussion on when it may be available for use in actual aircraft maintenance programs. It should be noted that this is a companion document to DOT/FAA/CT-91/5, Current Nondestructive Inspection Methods for Aging Aircraft.

  3. Field Operations and Enforcement Manual for Air Pollution Control. Volume III: Inspection Procedures for Specific Industries.

    Science.gov (United States)

    Weisburd, Melvin I.

    The Field Operations and Enforcement Manual for Air Pollution Control, Volume III, explains in detail the following: inspection procedures for specific sources, kraft pulp mills, animal rendering, steel mill furnaces, coking operations, petroleum refineries, chemical plants, non-ferrous smelting and refining, foundries, cement plants, aluminum…

  4. Inspection methods and their selection

    International Nuclear Information System (INIS)

    Maier, H.J.

    1980-01-01

    First those nondestructive testing methods, which are used in quality assurance, are to be treated, e.g. - ultrasonics - radiography - magnetic particle testing - dye penetrant testing - eddy currents, and their capabilities and limitations are shown. Second the selection of optimal testing methods under the aspect of defect recognition in different materials and components are shown. (orig./RW)

  5. Method and apparatus for inspecting tires

    International Nuclear Information System (INIS)

    Fox, R.L.T.

    1975-01-01

    A method and apparatus for inspecting tires by the use of x-rays is disclosed in which a tire is advanced to an inspection station, engaged along opposite bead rims and inflated to axially spread the bead rims and side walls. An x-ray source is advanced axially into the tire and the tire is eccentrically rotated relative to the x-ray source to enable radial positioning of the source relative to the tire near the tire bead rim diameter without requiring radial movement of the x-ray source. The x-ray source produces an x-ray beam which sweeps about the interior of the expanded tire from bead rim to bead rim while the tire is rotated about its centerline. An x-ray detection system detects x-rays which have penetrated the wall and produces inspection information concerning the tire construction. (Patent Office Record)

  6. Probabilistic methodology for assessing steam generator tube inspection - Phase II: User's manual for CANTIA Version 1.1

    International Nuclear Information System (INIS)

    Harris, J.E.; Gorman, J.A.; Turner, A.P.L.

    1997-03-01

    The objectives of this project were to develop a computer-based method for probabilistic assessment of inspection strategies for steam generator tubes, and to document the source code and to provide a user's manual for it. The program CANTIA was created to fulfill this objective, and the user's manual is provided in this volume. The documentation and verification of the CANTIA code is provided as a separate report. CANTIA uses Monte Carlo techniques to determine approximate probabilities of steam generator tube failures under accident conditions and primary-to-secondary leak rates under normal and accident conditions at future points in time. The program also determines approximate future flaw distributions and non-destructive examination results from the input data. The probabilities of failure and leak rates and the future flaw distributions can be influenced by performing inspections of the steam generator tubes at some future points in time, and removing defective tubes from the population. The effect of different inspection and maintenance strategies can therefore be determined as a direct effect on the probability of tube failure and primary-to-secondary leak rate

  7. Method of inspecting control rod drive mechanism

    International Nuclear Information System (INIS)

    Sato, Tomomi; Tatemichi, Shin-ichiro; Hasegawa, Hidenobu.

    1988-01-01

    Purpose: To conduct inspection for control rod drives and fuel handling operations in parallel without taking out the entire fuel, while maintaining the reactor in a subcritical state. Method: Control rod drives are inspected through the release of connection between control rods and control rod drives, detachment and dismantling of control rod drives, etc. In this case, structural materials having neutron absorbing power equal to or greater than the control rods are inserted into the gap after taking out fuels. Since the structural materials have neutron absorbing portion, subcriticality is maintained by the neutron absorbing effect. Accordingly, there is no requirement for taking out all of the fuels, thereby enabling to check the control rod drives and conduct handling for the fuels in parallel. As a result, the number of days required for the inspection can be shortened and it is possible to improve the working efficiency for the decomposition, inspection, etc. of the control rod drives and, thus, improve the operation efficiency of the nuclear power plant thereby attaining the predetermined purpose. (Kawakami, Y.)

  8. Biological Methods and Manual Development

    Science.gov (United States)

    EPA scientists conduct research to develop and evaluate analytical methods for the identification, enumeration, evaluation of aquatic organisms exposed to environmental stressors and to correlate exposures with effects on chemical and biological indicators

  9. Inspection methods progression of diabetic optic neuropathy

    Directory of Open Access Journals (Sweden)

    Yan Sun

    2015-06-01

    Full Text Available Increasing incidence of diabetes, diet restructuring with excessive intake of high-calorie foods closely related with this. Currently diabetes prevalence rate increased from 7% in 2003 to 14% in 2010. Diabetes can cause a variety of eye diseases, such as corneal ulcers, glaucoma, vitreous hemorrhage and so on. Diabetic retinopathy and cataract are the most common and greater impact on patients. At present, study for diabetic retinopathy(DRis wider than diabetes optic neuropathy(DON. Clinical manifestations of DON are not specific, but DON occurred extensively, also contributed to an important cause of blindness.In this paper, we collected a variety of inspection and early diagnosis methods, try to achieve early detection, interventional therapy and good treatment for this disease. Here to make a presentation on the various types of inspection methods.

  10. User's manual for remote-handled transuranic waste container welding and inspection fixture

    International Nuclear Information System (INIS)

    Hauptmann, J.P.

    1985-09-01

    Rockwell Hanford Operations (Rockwell) has designed built, and tested a prototype remotely operated welding and inspection fixture to be used in making the closure weld on the remote-handled transuranic (RH-TRU) waste container. The RH-TRU waste container has an average TRU concentration in excess of 100 nCi/gm, and a surface radiation dose rate in excess of 200 mrem/h, but not exceeding 100 rem/h. The RH-TRU waste container is to be used by defense waste generator sites in the United States for final packaging of RH-TRU wastes and is compatible with the requirements of the Waste Isolation Pilot Plant (WIPP) and the WIPP handling system. Standard and stacked RH-TRU container designs are available. The standard container is 26 in. in dia. by 121 in. high; the stacked containers are 26 in. in dia. by 61.25 in. high. After loading, two stacked containers are fitted and welded together to form the identical measurements of the standard 121-in. container. The prototype RH-TRU waste container welding and inspection fixture was intended for test and evaluation only, and not for installation in an operating facility. The final RH-TRU waste container welding and inspection fixture drawings (see appendix) incorporate several changes made following operational testing of the original fixture. These modifications are identified in this manual. However, not all modifications have been functionally tested. The purpose of this manual is to aid waste generator sites in designing a remotely operated welding and inspection fixture that will conform to their own requirements. Modifications to the Rockwell design must be evaluated for structural and WIPP handling requirements. This manual also provides design philosophy, component vendor information, and cost estimates

  11. Assessment of the reliability of ultrasonic inspection methods

    International Nuclear Information System (INIS)

    Haines, N.F.; Langston, D.B.; Green, A.J.; Wilson, R.

    1982-01-01

    The reliability of NDT techniques has remained an open question for many years. A reliable technique may be defined as one that, when rigorously applied by a number of inspection teams, consistently finds then correctly sizes all defects of concern. In this paper we report an assessment of the reliability of defect detection by manual ultrasonic methods applied to the inspection of thick section pressure vessel weldments. Initially we consider the available data relating to the inherent physical capabilities of ultrasonic techniques to detect cracks in weldment and then, independently, we assess the likely variability in team to team performance when several teams are asked to follow the same specified test procedure. The two aspects of 'capability' and 'variability' are brought together to provide quantitative estimates of the overall reliability of ultrasonic inspection of thick section pressure vessel weldments based on currently existing data. The final section of the paper considers current research programmes on reliability and presents a view on how these will help to further improve NDT reliability. (author)

  12. Methods and apparatus for multi-parameter acoustic signature inspection

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, Aaron A [Richland, WA; Samuel, Todd J [Pasco, WA; Valencia, Juan D [Kennewick, WA; Gervais, Kevin L [Richland, WA; Tucker, Brian J [Pasco, WA; Kirihara, Leslie J [Richland, WA; Skorpik, James R [Kennewick, WA; Reid, Larry D [Benton City, WA; Munley, John T [Benton City, WA; Pappas, Richard A [Richland, WA; Wright, Bob W [West Richland, WA; Panetta, Paul D [Richland, WA; Thompson, Jason S [Richland, WA

    2007-07-24

    A multiparameter acoustic signature inspection device and method are described for non-invasive inspection of containers. Dual acoustic signatures discriminate between various fluids and materials for identification of the same.

  13. Probabilistic methodology for assessing steam generator tube inspection - Phase II: CANTIA - a probabilistic method for assessing steam generator tube inspections

    International Nuclear Information System (INIS)

    Harris, J.E.; Gorman, J.A.; Turner, A.P.L.

    1997-03-01

    The objectives of this project were to develop a computer-based method for probabilistic assessment of inspection strategies for steam generator tubes, and to document the source code and to provide a user's manual for it. The program CANTIA was created to fulfill this objective, and the documentation and verification of the code is provided in this volume. The user's manual for CANTIA is provided as a separate report. CANTIA uses Monte Carlo techniques to determine approximate probabilities of steam generator tube failures under accident conditions and primary-to-secondary leak rates under normal and accident conditions at future points in time. The program also determines approximate future flaw distributions and non-destructive examination results from the input data. The probabilities of failure and leak rates and the future flaw distributions can be influenced by performing inspections of the steam generator tubes at some future points in time, and removing defective tubes from the population. The effect of different inspection and maintenance strategies can therefore be determined as a direct effect on the probability of tube failure and primary-to-secondary leak rate

  14. Yeast genetics. A manual of methods

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, J.F.T.; Spencer, D.M.; Bruce, I.J.

    1989-01-01

    This is a bench-top manual of methods needed both for classical genetics as related to yeasts, such as mating, sporulation, isolation of hybrids, microdissection of asci for the isolation of single-spore clones, as well as for mapping of genes and the construction of new strains by protoplast fusion. Special emphasis is on mutations in general, and on methods of isolating a number of important classes of mutants in particular. Basic techniques for the separation of chromosomes by electrophoresis, such as OFAGE, FIGE, and CHEF, are discussed, with detailed protocols for the first two. Furthermore, new methods, e.g. for the isolation of high molecular weight DNA from yeast, isolation of RNA, and techniques for transformation of yeasts, are also described in detail. (orig.) With 10 figs.

  15. Accountability methods for plutonium and uranium: the NRC manuals

    Energy Technology Data Exchange (ETDEWEB)

    Gutmacher, R.G.; Stephens, F.B.

    1977-09-28

    Four manuals containing methods for the accountability of plutonium nitrate solutions, plutonium dioxide, uranium dioxide and mixed uranium-plutonium oxide have been prepared by us and issued by the U.S. Nuclear Regulatory Commission. A similar manual on methods for the accountability of uranium and plutonium in reprocessing plant dissolver solutions is now in preparation. In the present paper, we discuss the contents of the previously issued manuals and give a preview of the manual now being prepared.

  16. Accountability methods for plutonium and uranium: the NRC manuals

    International Nuclear Information System (INIS)

    Gutmacher, R.G.; Stephens, F.B.

    1977-01-01

    Four manuals containing methods for the accountability of plutonium nitrate solutions, plutonium dioxide, uranium dioxide and mixed uranium-plutonium oxide have been prepared by us and issued by the U.S. Nuclear Regulatory Commission. A similar manual on methods for the accountability of uranium and plutonium in reprocessing plant dissolver solutions is now in preparation. In the present paper, we discuss the contents of the previously issued manuals and give a preview of the manual now being prepared

  17. Field Operations and Enforcement Manual for Air Pollution Control. Volume II: Control Technology and General Source Inspection.

    Science.gov (United States)

    Weisburd, Melvin I.

    The Field Operations and Enforcement Manual for Air Pollution Control, Volume II, explains in detail the following: technology of source control, modification of operations, particulate control equipment, sulfur dioxide removal systems for power plants, and control equipment for gases and vapors; inspection procedures for general sources, fuel…

  18. Demonstration test of in-service inspection methods

    International Nuclear Information System (INIS)

    Takumi, Kenji

    1987-01-01

    The major objectives of the project are: (1) to demonstrate the reliability of a manual ultrasonic flaw detector and techniques that are used in operating light water reactor plants and (2) to demonstrate the performance and reliability of an automatic ultrasonic flaw detector that is designed to shorten the time required for ISI work and reduce the exposure risk of inspection personnel. The test project consists of three stages. In the first stage, which ended in 1982, defects were added intentionally to a model structure the same in size as a typical 1.1 million kW BWR plant and manual ultrasonic flaw detection tensting was performed. In the second stage, completed in 1984, automatic eddy-current flaw detection testing was carried out for defects in heat transfer piping of a PWP steam generator. In the third stage, which started in 1981 and ended in March 1987, a newly developed automatic ultrasonic flaw detector is applied to testing of defects used for the manual detector performance evaluation. Results have shown that the automatic eddy-current flaw detector under test has an adequately stable performance for practical uses, with a very high reproducibility to permit close inspection of secular deterioration in heat transfer pipes. It has also revealed that both the manual and automatic ultrasonic flaw detectors under test can detect all defects that do not comply with the ASME standards. (Nogami, K.)

  19. Study on the inspection item and inspection method of HTGR fuel

    International Nuclear Information System (INIS)

    Na, Sang Ho; Kim, Y. K.; Jeong, K. C.; Oh, S. C.; Cho, M. S.; Kim, Y. M.; Lee, Y. W.

    2006-01-01

    The type of HTGR(High Temperature Gas-cooled Reactor) fuel is different according to the reactor type. Generally the HTGR fuel has two types. One is a block type, which is manufactured in Japan or America. And the other is a pebble type, which is manufactured in China. Regardless of the fuel type, the fuel manufacturing process started from the coated particle, which is consisted of fuel kernel and the 4 coating layers. Korea has a plan to fabricate a HTGR fuel in near future. The appropriate quality inspection standards are requested to produce a sound and reliable coated particle for HTGR fuel. Therefore, the inspection items and the inspection methods of HTGR fuel between Japan and China, which countries have the manufacturing process, are investigated to establish a proper inspection standards of our product characteristics

  20. Machine vision method for online surface inspection of easy open can ends

    Science.gov (United States)

    Mariño, Perfecto; Pastoriza, Vicente; Santamaría, Miguel

    2006-10-01

    Easy open can end manufacturing process in the food canning sector currently makes use of a manual, non-destructive testing procedure to guarantee can end repair coating quality. This surface inspection is based on a visual inspection made by human inspectors. Due to the high production rate (100 to 500 ends per minute) only a small part of each lot is verified (statistical sampling), then an automatic, online, inspection system, based on machine vision, has been developed to improve this quality control. The inspection system uses a fuzzy model to make the acceptance/rejection decision for each can end from the information obtained by the vision sensor. In this work, the inspection method is presented. This surface inspection system checks the total production, classifies the ends in agreement with an expert human inspector, supplies interpretability to the operators in order to find out the failure causes and reduce mean time to repair during failures, and allows to modify the minimum can end repair coating quality.

  1. Statistical methods for the planning of inspections

    International Nuclear Information System (INIS)

    Hough, C.G.; Beetle, T.M.

    1976-01-01

    Inspection plans are designed to detect diversions of M kilograms of nuclear material with a high degree of confidence. Attribute sample plans were first developed and applied at a zero-energy fast reactor in the United Kingdom in co-operation with the Agency. Battelle-Northwest in the United States of America proposed a variables sample plan based on decision theory. The Karlsruhe Research Center in the Federal Republic of Germany developed the strategic points concept and sample plans based on game theory considerations. All these approaches were combined into a common approach which is summarized in this report. (author)

  2. Method for inspecting nuclear reactor fuel elements

    International Nuclear Information System (INIS)

    Jabsen, F.S.

    1979-01-01

    A technique for disassembling a nuclear reactor fuel element without destroying the individual fuel pins and other structural components from which the element is assembled is described. A traveling bridge and trolley span a water-filled spent fuel storage pool and support a strongback. The strongback is under water and provides a working surface on which the spent fuel element is placed for inspection and for the manipulation that is associated with disassembly and assembly. To remove, in a non-destructive manner, the grids that hold the fuel pins in the proper relative positions within the element, bars are inserted through apertures in the grids with the aid of special tools. These bars are rotated to flex the adjacent grid walls and, in this way relax the physical engagement between protruding portions of the grid walls and the associated fuel pins. With the grid structure so flexed to relax the physical grip on the individual fuel pins, these pins can be withdrawn for inspection or replacement as necessary without imposing a need to destroy fuel element components

  3. Information to licensees regarding two NRC Inspection Manual sections on resolution of degraded and nonconforming conditions and on operability (Generic Letter 91-18)

    International Nuclear Information System (INIS)

    Partlow, J.G.

    1992-01-01

    The NRC staff has issued two sections to be included in Part 9900, Technical Guidance, of the NRC Inspection Manual. The first is, ''Resolution of Degraded and Nonconforming Conditions.'' The second is, ''Operable/Operability: Ensuring the Functional Capability of a System or Component.'' Copies of the additions to the NRC Inspection Manual are provided for information only. No specific licensee actions are required. The additions to the NRC Inspection Manual are based upon previously issued guidance. However, because of the complexity involved in operability determinations and the resolution of degraded and nonconforming conditions, there have been differences in application by NRC staff during past inspection activities. Thus, the purpose of publishing this guidance is to ensure consistency in application of this guidance by the NRC. Regional inspection personnel have been briefed on this guidance. The NRC will conduct further training on these topics to ensure uniform staff understanding

  4. Automated ultrasonic inspection of nuclear plant components

    International Nuclear Information System (INIS)

    Baron, J.A.; Dolbey, M.P.

    1982-01-01

    For reasons of safety and efficiency, automated systems are used in performing ultrasonic inspection of nuclear components. An automated system designed specifically for the inspection of headers in a nuclear plant is described. In-service inspection results obtained with this system are shown to correlate with pre-service inspection results obtained by manual methods

  5. Method of analyzing the shipping inspection water in nuclear fuels

    International Nuclear Information System (INIS)

    Ishikawa, Tatsuo; Izumoji, Yoshiaki.

    1984-01-01

    Purpose: To automatically perform radioactive-corrosion-products removing operation and thereby automatic analysis for shipping inspection water. Method: An radioactive-corrosion-product removing device has a column filled with a chelate resin layer. Shipping-inspection water as a specimen is injected from a sample-water inlet to the column, passes through the chelate resin layer, issues through the sample-water exit and is then stored once in a sample collector. The shipping inspection water sampled in the sampling collector is sent to an inspection port in an on-line or off-line manner and gamma-ray determination is made by a gamma-ray spectrum analyzer. (Horiuchi, T.)

  6. Characterization of Developer Application Methods Used in Fluorescent Penetrant Inspection

    Science.gov (United States)

    Brasche, L. J. H.; Lopez, R.; Eisenmann, D.

    2006-03-01

    Fluorescent penetrant inspection (FPI) is the most widely used inspection method for aviation components seeing use for production as well as an inservice inspection applications. FPI is a multiple step process requiring attention to the process parameters for each step in order to enable a successful inspection. A multiyear program is underway to evaluate the most important factors affecting the performance of FPI, to determine whether existing industry specifications adequately address control of the process parameters, and to provide the needed engineering data to the public domain. The final step prior to the inspection is the application of developer with typical aviation inspections involving the use of dry powder (form d) usually applied using either a pressure wand or dust storm chamber. Results from several typical dust storm chambers and wand applications have shown less than optimal performance. Measurements of indication brightness and recording of the UVA image, and in some cases, formal probability of detection (POD) studies were used to assess the developer application methods. Key conclusions and initial recommendations are provided.

  7. A Novel Method of Autonomous Inspection for Transmission Line based on Cable Inspection Robot LiDAR Data

    Directory of Open Access Journals (Sweden)

    Xinyan Qin

    2018-02-01

    Full Text Available With the growth of the national economy, there is increasing demand for electricity, which forces transmission line corridors to become structurally complicated and extend to complex environments (e.g., mountains, forests. It is a great challenge to inspect transmission line in these regions. To address these difficulties, a novel method of autonomous inspection for transmission line is proposed based on cable inspection robot (CIR LiDAR data, which mainly includes two steps: preliminary inspection and autonomous inspection. In preliminary inspection, the position and orientation system (POS data is used for original point cloud dividing, ground point filtering, and structured partition. A hierarchical classification strategy is established to identify the classes and positions of the abnormal points. In autonomous inspection, CIR can autonomously reach the specified points through inspection planning. These inspection targets are imaged with PTZ (pan, tilt, zoom cameras by coordinate transformation. The feasibility and effectiveness of the proposed method are verified by test site experiments and actual line experiments, respectively. The proposed method greatly reduces manpower and improves inspection accuracy, providing a theoretical basis for intelligent inspection of transmission lines in the future.

  8. Slaughterhouse Inspection (Egypt). Training Manual : Guidelines for the Planning and Organisation of Training Activities

    NARCIS (Netherlands)

    Blomne Sopov, M.; Ghouti, C.A.; Benlafquih, R.; Vugt, van F.; Latief, A.M.A.

    2014-01-01

    The training manual was prepared for the inspectors of slaughterhouses in Egypt to support the training activities of the General Organization for Veterinary Services (GOVS). The manual has two main parts: 1. Overview on how to design, organize, implement and evaluate training programs in general 2.

  9. In-service inspection methods for graphite-epoxy structures on commercial transport aircraft

    Science.gov (United States)

    Phelps, M. L.

    1981-01-01

    In-service inspection methods for graphite-epoxy composite structures on commercial transport aircraft are determined. Graphite/epoxy structures, service incurred defects, current inspection practices and concerns of the airline and manufacturers, and other related information were determind by survey. Based on this information, applicable inspection nondestructive inspection methods are evaluated and inspection techniques determined. Technology is developed primarily in eddy current inspection.

  10. A novel method for surface defect inspection of optic cable with short-wave infrared illuminance

    Science.gov (United States)

    Chen, Xiaohong; Liu, Ning; You, Bo; Xiao, Bin

    2016-07-01

    Intelligent on-line detection of cable quality is a crucial issue in optic cable factory, and defects on the surface of optic cable can dramatically depress cable grade. Manual inspection in optic cable quality cannot catch up with the development of optic cable industry due to its low detection efficiency and huge human cost. Therefore, real-time is highly demanded by industry in order to replace the subjective and repetitive process of manual inspection. For this reason, automatic cable defect inspection has been a trend. In this paper, a novel method for surface defect inspection of optic cable with short-wave infrared illuminance is presented. The special condition of short-wave infrared cannot only provide illumination compensation for the weak illumination environment, but also can avoid the problem of exposure when using visible light illuminance, which affects the accuracy of inspection algorithm. A series of image processing algorithms are set up to analyze cable image for the verification of real-time and veracity of the detection method. Unlike some existing detection algorithms which concentrate on the characteristics of defects with an active search way, the proposed method removes the non-defective areas of the image passively at the same time of image processing, which reduces a large amount of computation. OTSU algorithm is used to convert the gray image to the binary image. Furthermore, a threshold window is designed to eliminate the fake defects, and the threshold represents the considered minimum size of defects ε . Besides, a new regional suppression method is proposed to deal with the edge burrs of the cable, which shows the superior performance compared with that of Open-Close operation of mathematical morphological in the boundary processing. Experimental results of 10,000 samples show that the rates of miss detection and false detection are 2.35% and 0.78% respectively when ε equals to 0.5 mm, and the average processing period of one frame

  11. A manual of analytical methods used at MINTEK

    International Nuclear Information System (INIS)

    Stoch, H.; Dixon, K.

    1983-01-01

    The manual deals with various methods for a wide range of elemental analysis. Some of the methods that are used, include atomic absorption spectroscopy, optical emission spectroscopy and x-ray fluoresence spectroscopy. The basic charateristics of the method are given and the procedures are recorded step by step. One of the sections deals with methods associated with the recovery of uranium

  12. Method of monitoring, inspecting or testing conveyor belts

    International Nuclear Information System (INIS)

    Van der Walt, A.J.

    1985-01-01

    An invention is discussed which provides a method, installation and kit for monitoring, inspecting or testing a conveyor belt. Provision is made to transmit penetrating rays such as X-rays through a moving conveyor belt, forming a visible moving image from rays transmitted through the belt, and visually inspecting such moving image, after recording it if desired, to ascertain the condition of the interior of the belt. Typically an X-ray tube head is used to transmit the rays through the belt to a fluorescent screen which forms the image. The moving image can be recorded by means of a video camera

  13. Research on nondestructive examination methods for CANDU fuel channel inspection

    International Nuclear Information System (INIS)

    Soare, M.; Petriu, F.; Toma, V.; Revenco, V.; Calinescu, A.; Ciocan, R.; Iordache, C.; Popescu, L.; Mihalache, M.; Murgescu, C.

    1995-01-01

    The requirements of the 1994 edition of CAN/CSA-N285.4 Periodic Inspection Standard, which address all known and postulated degradation mechanisms and introduce material surveillance demands, involve a growing need for improved nondestructive examination (NDE) methods and technologies. In order to have a proper technical support in its decisions concerning fuel channel inspections at Cernavoda NPP, the Romanian Power Authority (RENEL) initiated a Research Program regarding the nondestructive characterization of the fuel channels structural integrity. The paper presents the most significant results obtained on this Research Program: the ENDUS experimental system for Laboratory simulation of the fuel channel inspection, ultrasonic Rayleigh-Lamb waves technique for pressure tubes examination, phase analysis technique for near-surface flaws, influence of the metallurgical state of the pressure tube material on the eddy current defectoscopic signals, characterization of plastic deformation and fracture of zirconium alloys by acoustic emission. (author)

  14. 7 CFR 51.2947 - Method of inspection.

    Science.gov (United States)

    2010-01-01

    ... internal defects. The nuts must meet the requirements for both external and internal quality in order to... 7 Agriculture 2 2010-01-01 2010-01-01 false Method of inspection. 51.2947 Section 51.2947 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards...

  15. Transuranic waste characterization sampling and analysis methods manual. Revision 1

    International Nuclear Information System (INIS)

    Suermann, J.F.

    1996-04-01

    This Methods Manual provides a unified source of information on the sampling and analytical techniques that enable Department of Energy (DOE) facilities to comply with the requirements established in the current revision of the Transuranic Waste Characterization Quality Assurance Program Plan (QAPP) for the Waste Isolation Pilot Plant (WIPP) Transuranic (TRU) Waste Characterization Program (the Program) and the WIPP Waste Analysis Plan. This Methods Manual includes all of the testing, sampling, and analytical methodologies accepted by DOE for use in implementing the Program requirements specified in the QAPP and the WIPP Waste Analysis Plan. The procedures in this Methods Manual are comprehensive and detailed and are designed to provide the necessary guidance for the preparation of site-specific procedures. With some analytical methods, such as Gas Chromatography/Mass Spectrometry, the Methods Manual procedures may be used directly. With other methods, such as nondestructive characterization, the Methods Manual provides guidance rather than a step-by-step procedure. Sites must meet all of the specified quality control requirements of the applicable procedure. Each DOE site must document the details of the procedures it will use and demonstrate the efficacy of such procedures to the Manager, National TRU Program Waste Characterization, during Waste Characterization and Certification audits

  16. A pattern-based method to automate mask inspection files

    Science.gov (United States)

    Kamal Baharin, Ezni Aznida Binti; Muhsain, Mohamad Fahmi Bin; Ahmad Ibrahim, Muhamad Asraf Bin; Ahmad Noorhani, Ahmad Nurul Ihsan Bin; Sweis, Jason; Lai, Ya-Chieh; Hurat, Philippe

    2017-03-01

    Mask inspection is a critical step in the mask manufacturing process in order to ensure all dimensions printed are within the needed tolerances. This becomes even more challenging as the device nodes shrink and the complexity of the tapeout increases. Thus, the amount of measurement points and their critical dimension (CD) types are increasing to ensure the quality of the mask. In addition to the mask quality, there is a significant amount of manpower needed when the preparation and debugging of this process are not automated. By utilizing a novel pattern search technology with the ability to measure and report match region scan-line (edge) measurements, we can create a flow to find, measure and mark all metrology locations of interest and provide this automated report to the mask shop for inspection. A digital library is created based on the technology product and node which contains the test patterns to be measured. This paper will discuss how these digital libraries will be generated and then utilized. As a time-critical part of the manufacturing process, this can also reduce the data preparation cycle time, minimize the amount of manual/human error in naming and measuring the various locations, reduce the risk of wrong/missing CD locations, and reduce the amount of manpower needed overall. We will also review an example pattern and how the reporting structure to the mask shop can be processed. This entire process can now be fully automated.

  17. Selection of suitable NDT methods for building inspection

    Science.gov (United States)

    Pauzi Ismail, Mohamad

    2017-11-01

    Construction of modern structures requires good quality concrete with adequate strength and durability. Several accidents occurred in the civil constructions and were reported in the media. Such accidents were due to poor workmanship and lack of systematic monitoring during the constructions. In addition, water leaking and cracking in residential houses was commonly reported too. Based on these facts, monitoring the quality of concrete in structures is becoming more and more important subject. This paper describes major Non-destructive Testing (NDT) methods for evaluating structural integrity of concrete building. Some interesting findings during actual NDT inspections on site are presented. The NDT methods used are explained, compared and discussed. The suitable methods are suggested as minimum NDT methods to cover parameters required in the inspection.

  18. Qualification of Manual Phased Array Ultrasonic Techniques for Pipe Weld Inspection in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, J.; Hayes, P.; Vicat, F. [GE Inspection Technologies (United States)

    2011-07-01

    Phasor XS can be used for piping weld inspection in any facilities that use EPRI procedures (example: nuclear power plant in Usa, Japan, ...). Whole pipe range is inspected with 5 probes and 6 wedges: 4 1-dimensional probe for sound wave scanning (different frequency, different apertures); 1 dual matrix probe for LW scanning; there are 3 types of wedges optimized for weld inspection. Weld is scanned in 'Raster Scan', maximum range from 35 up to 80 degrees. Probe selection is defined in the procedure according to pipe diameter, pipe thickness and type of access (single or dual side). We have to note that datasets for dual matrix probe are provided with the procedure because this kind of probe cannot be programmed inside Phasor XS

  19. Full surface inspection methods regarding reinforcement corrosion of concrete structures

    International Nuclear Information System (INIS)

    Reichling, K.; Raupach, M.; Broomfield, J.; Gulikers, J.; L'Hostis, Valerie

    2013-01-01

    For reinforced concrete structures a localisation of all significant critical areas can only be done by a full surface inspection. The economic advantages are obvious: uncritical areas have not to be repaired expensively.The first step of the assessment should always be a visual inspection. The range of deterioration causes can be limited and the degree of deterioration may be estimated roughly. The inspection program can be adjusted to the requirements. By means of a full surface potential mapping areas with a high risk for chloride induced reinforcement corrosion can be localised, although no deteriorations are visually detectable at the concrete surface. In combination with concrete cover depth and resistivity measurements areas with corrosion promoting exposure conditions can be localised even if the reinforcement is not yet de-passivated. The following publication gives an overview about the essential full surface investigation methods to localise critical areas regarding corrosion of steel in concrete. The selection of methods is based on the inspection procedure given in reference 2. (authors)

  20. ACARP Project C10059. ACARP manual of modern coal testing methods. Volume 1: The manual

    Energy Technology Data Exchange (ETDEWEB)

    Sakurovs, R.; Creelman, R.; Pohl, J.; Juniper, L. [CSIRO Energy Technology, Sydney, NSW (Australia)

    2002-07-01

    The Manual summarises the purpose, applicability, and limitations of a range of standard and modern coal testing methods that have potential to assist the coal company technologist to better evaluate coal performance. The first volume sets out the Modern Coal Testing Methods in summarised form that can be used as a quick guide to practitioners to assist in selecting the best technique to solve their problems.

  1. Two-Dimensional Impact Reconstruction Method for Rail Defect Inspection

    Directory of Open Access Journals (Sweden)

    Jie Zhao

    2014-01-01

    Full Text Available The safety of train operating is seriously menaced by the rail defects, so it is of great significance to inspect rail defects dynamically while the train is operating. This paper presents a two-dimensional impact reconstruction method to realize the on-line inspection of rail defects. The proposed method utilizes preprocessing technology to convert time domain vertical vibration signals acquired by wireless sensor network to space signals. The modern time-frequency analysis method is improved to reconstruct the obtained multisensor information. Then, the image fusion processing technology based on spectrum threshold processing and node color labeling is proposed to reduce the noise, and blank the periodic impact signal caused by rail joints and locomotive running gear. This method can convert the aperiodic impact signals caused by rail defects to partial periodic impact signals, and locate the rail defects. An application indicates that the two-dimensional impact reconstruction method could display the impact caused by rail defects obviously, and is an effective on-line rail defects inspection method.

  2. Development of digital radiographic inspection method in MINT

    International Nuclear Information System (INIS)

    Mohd Ashhar Khalid; Abdul Razak Hamzah; Abdul Aziz Mohamad; Anuar Mikdad Muad; Nolida Yussup; Maslina Mohd Ibrahim

    2002-01-01

    Industrial radiography has been employed for the evaluation of defects, such as cracks, porosity and foreign inclusions found in casting and welds. It has become one of the major techniques in industrial non-destructive testing for the past 40 years. Although this technique has been well developed, further improvement can be implemented especially with the advancement of electronics and computer technology. Digital image processing techniques and application of artificial intelligence methods allow the interpretation of the image to be automated, avoiding the presence of human operators making the inspection system faster, more reliable and reproducible. Numerous works has been reported by various groups on the development of an automated, computer based evaluation algorithms. This paper reports the development and progress of digital radiographic inspection method in MINT. (Author)

  3. User's Manual for FEM-BEM Method. 1.0

    Science.gov (United States)

    Butler, Theresa; Deshpande, M. D. (Technical Monitor)

    2002-01-01

    A user's manual for using FORTRAN code to perform electromagnetic analysis of arbitrarily shaped material cylinders using a hybrid method that combines the finite element method (FEM) and the boundary element method (BEM). In this method, the material cylinder is enclosed by a fictitious boundary and the Maxwell's equations are solved by FEM inside the boundary and by BEM outside the boundary. The electromagnetic scattering on several arbitrarily shaped material cylinders using this FORTRAN code is computed to as examples.

  4. Development of ultrasonic inspection equipment using phased array method

    International Nuclear Information System (INIS)

    Kikuchi, Osamu; Yamatoya, Naofumi; Umino, Tomohiro; Baba, Atsushi

    2008-01-01

    This study presents new phased array UT equipments, one is developed as portable type for field inspection and the other is developed for 2D-matrix array (3D Focus-UT). The pulser of square burst wave was adopted for these new equipments to enhance flaw echo amplitude. At over 3 cycles of square burst cycle, the authors confirmed over 10 dB enhancement of bottom echo amplitude. Moreover, a new flaw imaging method using S-SAFT was also adopted for equipments to improve SN ratio and flaw echo resolution in inspection image. The authors verified effects of S-SAFT using side drilled hole specimen, about 2 times of improvement of SN ratio and flaw echo resolution. (author)

  5. Manual method for dose calculation in gynecologic brachytherapy

    International Nuclear Information System (INIS)

    Vianello, Elizabeth A.; Almeida, Carlos E. de; Biaggio, Maria F. de

    1998-01-01

    This paper describes a manual method for dose calculation in brachytherapy of gynecological tumors, which allows the calculation of the doses at any plane or point of clinical interest. This method uses basic principles of vectorial algebra and the simulating orthogonal films taken from the patient with the applicators and dummy sources in place. The results obtained with method were compared with the values calculated with the values calculated with the treatment planning system model Theraplan and the agreement was better than 5% in most cases. The critical points associated with the final accuracy of the proposed method is related to the quality of the image and the appropriate selection of the magnification factors. This method is strongly recommended to the radiation oncology centers where are no treatment planning systems available and the dose calculations are manually done. (author)

  6. Method of inspecting Raschig rings by neutron absorption counting

    International Nuclear Information System (INIS)

    Morris, R.N.; Murri, R.L.; Hume, M.W.

    1979-01-01

    A neutron counting method for inspecting borosilicate glass Raschig rings and an apparatus designed specifically for this method are discussed. The neutron count ratios for rings of a given thickness show a linear correlation to the boron oxide content of the rings. The count ratio also has a linear relationship to the thickness of rings of a given boron oxide content. Consequently, the experimentally-determined count ratio and physically-measured thickness of Raschig rings can be used to statistically predict their boron oxide content and determine whether or not they meet quality control acceptance criteria

  7. Manual of selected physico-chemical analytical methods. IV

    International Nuclear Information System (INIS)

    Beran, M.; Klosova, E.; Krtil, J.; Sus, F.; Kuvik, V.; Vrbova, L.; Hamplova, M.; Lengyel, J.; Kelnar, L.; Zakouril, K.

    1990-11-01

    The Central Testing Laboratory of the Nuclear Research Institute at Rez has for a decade been participating in the development of analytical procedures and has been providing analyses of samples of different types and origin. The analytical procedures developed have been published in special journals and a number of them in the Manuals of analytical methods, in three parts. The 4th part of the Manual contains selected physico-chemical methods developed or modified by the Laboratory in the years 1986-1990 within the project ''Development of physico-chemical analytical methods''. In most cases, techniques are involved for non-nuclear applications. Some can find wider applications, especially in analyses of environmental samples. Others have been developed for specific cases of sample analyses or require special instrumentation (mass spectrometer), which partly restricts their applicability by other institutions. (author)

  8. An application of the eddy-current method for inspections of austenitic cladding

    International Nuclear Information System (INIS)

    Kubis, S.; Herka, M.; Krajcovic, R.

    1999-01-01

    The application of the eddy-current method for inspections of austenitic cladding by means of pancake probes. Phase and amplitude characteristics of artificial defects and anticipated interference signals. Optimization of inspection parameters

  9. Manual of analytical methods for the Industrial Hygiene Chemistry Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Greulich, K.A.; Gray, C.E. (comp.)

    1991-08-01

    This Manual is compiled from techniques used in the Industrial Hygiene Chemistry Laboratory of Sandia National Laboratories in Albuquerque, New Mexico. The procedures are similar to those used in other laboratories devoted to industrial hygiene practices. Some of the methods are standard; some, modified to suit our needs; and still others, developed at Sandia. The authors have attempted to present all methods in a simple and concise manner but in sufficient detail to make them readily usable. It is not to be inferred that these methods are universal for any type of sample, but they have been found very reliable for the types of samples mentioned.

  10. Manual of analytical methods for the Industrial Hygiene Chemistry Laboratory

    International Nuclear Information System (INIS)

    Greulich, K.A.; Gray, C.E.

    1991-08-01

    This Manual is compiled from techniques used in the Industrial Hygiene Chemistry Laboratory of Sandia National Laboratories in Albuquerque, New Mexico. The procedures are similar to those used in other laboratories devoted to industrial hygiene practices. Some of the methods are standard; some, modified to suit our needs; and still others, developed at Sandia. The authors have attempted to present all methods in a simple and concise manner but in sufficient detail to make them readily usable. It is not to be inferred that these methods are universal for any type of sample, but they have been found very reliable for the types of samples mentioned

  11. Method and apparatus for inspection of nuclear fuel rods

    International Nuclear Information System (INIS)

    Wachter, W.J.

    1977-01-01

    A method and apparatus are provided for the inspection of nuclear fuel rods to detect defects or failures in such rods. Assemblies of fuel rods are immersed in water and means are provided for causing a change in the relative pressures in the water and within the fuel rod such that fluid is expelled from the rod through any defects that may exist. Means are also provided for thereafter vibrating the rods to cause additional internal fluid or other material that may be trapped in the rod to be expelled. Sensors are provided for detecting the emission of bubbles of fluid or other material from the rod and for locating the position of the defective rod in the assembly. 5 figures

  12. Biological characteristics of crucian by quantitative inspection method

    Science.gov (United States)

    Chu, Mengqi

    2015-04-01

    Biological characteristics of crucian by quantitative inspection method Through quantitative inspection method , the biological characteristics of crucian was preliminary researched. Crucian , Belongs to Cypriniformes, Cyprinidae, Carassius auratus, is a kind of main plant-eating omnivorous fish,like Gregarious, selection and ranking. Crucian are widely distributed, perennial water all over the country all have production. Determine the indicators of crucian in the experiment, to understand the growth, reproduction situation of crucian in this area . Using the measured data (such as the scale length ,scale size and wheel diameter and so on) and related functional to calculate growth of crucian in any one year.According to the egg shape, color, weight ,etc to determine its maturity, with the mean egg diameter per 20 eggs and the number of eggs per 0.5 grams, to calculate the relative and absolute fecundity of the fish .Measured crucian were female puberty. Based on the relation between the scale diameter and length and the information, linear relationship between crucian scale diameter and length: y=1.530+3.0649. From the data, the fertility and is closely relative to the increase of age. The older, the more mature gonad development. The more amount of eggs. In addition, absolute fecundity increases with the pituitary gland.Through quantitative check crucian bait food intake by the object, reveals the main food, secondary foods, and chance food of crucian ,and understand that crucian degree of be fond of of all kinds of bait organisms.Fish fertility with weight gain, it has the characteristics of species and populations, and at the same tmes influenced by the age of the individual, body length, body weight, environmental conditions (especially the nutrition conditions), and breeding habits, spawning times factors and the size of the egg. After a series of studies of crucian biological character, provide the ecological basis for local crucian's feeding, breeding

  13. Comparison of Particulate Mercury Measured with Manual and Automated Methods

    Directory of Open Access Journals (Sweden)

    Rachel Russo

    2011-01-01

    Full Text Available A study was conducted to compare measuring particulate mercury (HgP with the manual filter method and the automated Tekran system. Simultaneous measurements were conducted with the Tekran and Teflon filter methodologies in the marine and coastal continental atmospheres. Overall, the filter HgP values were on the average 21% higher than the Tekran HgP, and >85% of the data were outside of ±25% region surrounding the 1:1 line. In some cases the filter values were as much as 3-fold greater, with

  14. A unique manual method for emergency offsite dose calculations

    International Nuclear Information System (INIS)

    Wildner, T.E.; Carson, B.H.; Shank, K.E.

    1987-01-01

    This paper describes a manual method developed for performance of emergency offsite dose calculations for PP and L's Susquehanna Steam Electric Station. The method is based on a three-part carbonless form. The front page guides the user through selection of the appropriate accident case and inclusion of meteorological and effluent data data. By circling the applicable accident descriptors, the user circles the dose factors on pages 2 and 3 which are then simply multiplied to yield the whole body and thyroid dose rates at the plant boundary, two, five, and ten miles. The process used to generate the worksheet is discussed, including the method used to incorporate the observed terrain effects on airflow patterns caused by the Susquehanna River Valley topography

  15. Endoscopic inspection of steam turbines

    International Nuclear Information System (INIS)

    Maliniemi, H.; Muukka, E.

    1990-01-01

    For over ten years, Imatran Voima Oy (IVO) has developed, complementary inspection methods for steam turbine condition monitoring, which can be applied both during operation and shutdown. One important method used periodically during outages is endoscopic inspection. The inspection is based on the method where the internal parts of the turbine is inspected through access borings with endoscope and where the magnified figures of the internal parts is seen on video screen. To improve inspection assurance, an image-processing based pattern recognition method for cracks has been developed for the endoscopic inspection of turbine blades. It is based on the deduction conditions derived from the crack shape. The computer gives an alarm of a crack detection and prints a simulated image of the crack, which is then checked manually

  16. Intelligent Automated Nuclear Fuel Pellet Inspection System

    International Nuclear Information System (INIS)

    Keyvan, S.

    1999-01-01

    At the present time, nuclear pellet inspection is performed manually using naked eyes for judgment and decisionmaking on accepting or rejecting pellets. This current practice of pellet inspection is tedious and subject to inconsistencies and error. Furthermore, unnecessary re-fabrication of pellets is costly and the presence of low quality pellets in a fuel assembly is unacceptable. To improve the quality control in nuclear fuel fabrication plants, an automated pellet inspection system based on advanced techniques is needed. Such a system addresses the following concerns of the current manual inspection method: (1) the reliability of inspection due to typical human errors, (2) radiation exposure to the workers, and (3) speed of inspection and its economical impact. The goal of this research is to develop an automated nuclear fuel pellet inspection system which is based on pellet video (photographic) images and uses artificial intelligence techniques

  17. Inspection methods for safeguards systems at nuclear facilities

    International Nuclear Information System (INIS)

    Minichino, C.; Richard, E.W.

    1981-01-01

    A project team at Lawrence Livermore National Laboratory has been developing inspection procedures and training materials for the NRC inspectors of safeguards systems at licensed nuclear facilities. This paper describes (1) procedures developed for inspecting for compliance with the Code of Federal Regulations, (2) training materials for safeguards inspectors on technical topics related to safeguards systems, such as computer surety, alarm systems, sampling techniques, and power supplies, and (3) an inspector-oriented methodology for evaluating the overall effectiveness of safeguards systems

  18. A method of size inspection for fruit with machine vision

    Science.gov (United States)

    Rao, Xiuqin; Ying, Yibin

    2005-11-01

    A real time machine vision system for fruit quality inspection was developed, which consists of rollers, an encoder, a lighting chamber, a TMS-7DSP CCD camera (PULNIX Inc.), a computer (P4 1.8G, 128M) and a set of grading controller. An image was binary, and the edge was detected with line-scanned based digit image description, and the MER was applied to detected size of the fruit, but failed. The reason for the result was that the test point with MER was different from which was done with vernier caliper. An improved method was developed, which was called as software vernier caliper. A line between weight O of the fruit and a point A on the edge was drawn, and then the crossed point between line OA and the edge was calculated, which was noted as B, a point C between AB was selected, and the point D on the other side was searched by a way to make CD was vertical to AB, by move the point C between point A and B, A new point D was searched. The maximum length of CD was recorded as an extremum value. By move point A from start to the half point on the edge, a serial of CD was gotten. 80 navel oranges were tested, the maximum error of the diameter was less than 1mm.

  19. Manual of analytical methods for the Environmental Health Laboratory

    International Nuclear Information System (INIS)

    Gray, C.E.

    1975-06-01

    The manual contains four sections: absorption spectrophotometry; general radiochemical procedures; instrumental analysis; and calibration of field instruments. Included in the individual analyses using absorption spectrophotometry is one for total iodine in oil. Radiochemical procedures are given for: actinides in urine and water; 137 Cs in soil and vegetation; 137 Cs in soil, urine, vegetation, and water; enriched uranium in urine; gross beta activity in soil, urine, vegetation, and water; plutonium in urine and soil; 210 Po in urine and water; 24 Na in air, blood, urine, and water; 90 Sr in soil, vegetation, and water; tritium in urine, water, and on swipes; and total uranium on fallout trays and in soil, urine, and water. Among the individual instrumental analyses is a spectrographic method for determining beryllium in air samples and swipes. (U.S.)

  20. In service inspection of pipes based on risk methods

    International Nuclear Information System (INIS)

    Mendoza G, G.; Viais J, J.; Carmona C, M.

    2006-01-01

    The politics of the Nuclear Regulatory Commission (by its initials in English NRC) of the United States of America on the use of the Probabilistic Safety Analysis (PSA) in activities of nuclear regulation it foments the use of this analysis technique to improve the decisions making, to reduce the unnecessary work in maintenance aspects, inspection and tests and to improve the regulatory efficiency. The inspection programs in service (ISI by its initials in English) developed by the American Society of Mechanical Engineers (by its initials in English ASME) it has been the one primary mechanism to prove the mechanical equipment in plants of nuclear energy, these programs indeed have been carried out in plants of nuclear energy by more of two decades. Their purpose is to identify the conditions, such as indications of cracks that are precursory of flights and ruptures which violate the integrity principles of the pressure frontier. The inspection in service activities include ultrasonic tests, surface tests and penetrating liquids test, also activities that include the scaffolds construction, removal of insulations and welding polishing. The inspections in service every 18 months during the times outside of service are executed. One of the objectives is to lower the costs of the inspections during the times outside of service and to reduce the exposure to the radiation by part of the personnel during these times out for inspections, while it is increased or it maintains the personnel's safety and the reliability. As part of the methodology a pipe segment is selected for which a fault in any point has the same consequences, being calculated the fault probability of the tube using the dimensions of the segment. In this work the inspection in service methodology is applied based on risk to an aspersion system of low pressure of the Laguna Verde Nucleo electric Central. For this system a reduction in the number of welding to inspect of 103 to only 15 is obtained

  1. Method of inspecting the function of reactor noise monitoring device

    International Nuclear Information System (INIS)

    Yamanaka, Hirohito.

    1985-01-01

    Purpose: To enable to inspect the function of a reactor noise monitoring device used for monitoring the operation abnormality in coolant circuits during reactor operation. Constitution: A cylinder incorporating a steel ball moved laterally by a pneumatic pressure is disposed to the main body of a reactor coolant circuit. A three-way solenoid valve disposed to a central control room outside to a radiation controlled area is connected with the cylinder by way of pneumatic pipeways. The three-way solenoid valve is operated for a certain period of time by a timer in the central control room to thereby impinge the steel ball in the cylinder against the main body of the coolant circuit and it is inspected as to whether the reactor noise monitoring system can detect the impinging energy or not. Accordingly, the remote control is possible from out of the radiation controlled area and the inspection work can be simplified. (Seki, T.)

  2. Apparatus for inspecting a group of containers and method of using same

    Science.gov (United States)

    Lee, Jr., James H.; Salton, Jonathan R [Albuquerque, NM; Spletzer, Barry L [Albuquerque, NM

    2012-02-28

    An apparatus and method for inspecting a plurality of containers are provided. Each container has an outer surface for housing at least one material therein. The techniques provided involve at least one inspection vehicle and at least one detector. Each inspection vehicle has a plurality of wheels for movably positioning about the plurality of containers. The wheels may have at least one magnet for selectively adhering to the outer surface of at least one of the containers whereby the inspection vehicle traverses the container(s). The detector is positionable proximate at least one of the containers. The detector may be deployable from the inspection vehicle to a position adjacent the container(s). The detector has at least one sensor for measuring at least one characteristic of the plurality of containers. At least one base station may be provided for communicating with the inspection vehicle(s) and/or detector(s).

  3. Ultrasonic inspection method and system for detection of steeple cracking in turbine disk rims

    International Nuclear Information System (INIS)

    Birring, A.S.; Lamping, G.A.; Van der Veer, W.R.; Hanley, J.J.

    1990-01-01

    Steam turbine disks which operate under high cyclic stress in a moist environment can develop cracks in the disk-rim steeples. Detection of these cracks using nondestructive testing methods is necessary to assure safe operation and avoid unnecessary disk replacement. Both magnetic particle (MT) and ultrasonic testing (UT) can be used to inspect the steeples; however, UT can be used without removing the blades. A system for inspecting bladed steeples has been developed that can be applied on a range of disks including those in Westinghouse, General Electric, and Allis Chalmers turbines. The system performs an inspection as the turbine is rotated at slow speeds over turning rolls. This procedure greatly reduces inspection time because the inspection can be done without deblading the disk or resetting the inspection equipment for different rim segments

  4. Comparisons of NDT Methods to Inspect Cork and Cork filled Epoxy Bands

    Science.gov (United States)

    Lingbloom, Mike

    2007-01-01

    Sheet cork and cork filled epoxy provide external insulation for the Reusable Solid Rocket Motor (RSRM) on the Nation's Space Transportation System (STS). Interest in the reliability of the external insulation bonds has increased since the Columbia incident. A non-destructive test (NDT) method that will provide the best inspection for these bonds has been under evaluation. Electronic Shearography has been selected as the primary NDT method for inspection of these bond lines in the RSRM production flow. ATK Launch Systems Group has purchased an electronic shearography system that includes a vacuum chamber that is used for evaluation of test parts and custom vacuum windows for inspection of full-scale motors. Although the electronic shearography technology has been selected as the primary method for inspection of the external bonds, other technologies that exist continue to be investigated. The NASA/Marshall Space Flight Center (MSFC) NDT department has inspected several samples for comparison with electronic shearography with various inspections systems in their laboratory. The systems that were evaluated are X-ray backscatter, terahertz imaging, and microwave imaging. The samples tested have some programmed flaws as well as some flaws that occurred naturally during the sample making process. These samples provide sufficient flaw variation for the evaluation of the different inspection systems. This paper will describe and compare the basic functionality, test method and test results including dissection for each inspection technology.

  5. Current automated 3D cell detection methods are not a suitable replacement for manual stereologic cell counting

    Directory of Open Access Journals (Sweden)

    Christoph eSchmitz

    2014-05-01

    Full Text Available Stereologic cell counting has had a major impact on the field of neuroscience. A major bottleneck in stereologic cell counting is that the user must manually decide whether or not each cell is counted according to three-dimensional (3D stereologic counting rules by visual inspection within hundreds of microscopic fields-of-view per investigated brain or brain region. Reliance on visual inspection forces stereologic cell counting to be very labor-intensive and time-consuming, and is the main reason why biased, non-stereologic two-dimensional (2D cell counting approaches have remained in widespread use. We present an evaluation of the performance of modern automated cell detection and segmentation algorithms as a potential alternative to the manual approach in stereologic cell counting. The image data used in this study were 3D microscopic images of thick brain tissue sections prepared with a variety of commonly used nuclear and cytoplasmic stains. The evaluation compared the numbers and locations of cells identified unambiguously and counted exhaustively by an expert observer with those found by three automated 3D cell detection algorithms: nuclei segmentation from the FARSIGHT toolkit, nuclei segmentation by 3D multiple level set methods, and the 3D object counter plug-in for ImageJ. Of these methods, FARSIGHT performed best, with true-positive detection rates between 38–99% and false-positive rates from 3.6–82%. The results demonstrate that the current automated methods suffer from lower detection rates and higher false-positive rates than are acceptable for obtaining valid estimates of cell numbers. Thus, at present, stereologic cell counting with manual decision for object inclusion according to unbiased stereologic counting rules remains the only adequate method for unbiased cell quantification in histologic tissue sections.

  6. Manual method for dose calculation in gynecologic brachytherapy; Metodo manual para o calculo de doses em braquiterapia ginecologica

    Energy Technology Data Exchange (ETDEWEB)

    Vianello, Elizabeth A.; Almeida, Carlos E. de [Instituto Nacional do Cancer, Rio de Janeiro, RJ (Brazil); Biaggio, Maria F. de [Universidade do Estado, Rio de Janeiro, RJ (Brazil)

    1998-09-01

    This paper describes a manual method for dose calculation in brachytherapy of gynecological tumors, which allows the calculation of the doses at any plane or point of clinical interest. This method uses basic principles of vectorial algebra and the simulating orthogonal films taken from the patient with the applicators and dummy sources in place. The results obtained with method were compared with the values calculated with the values calculated with the treatment planning system model Theraplan and the agreement was better than 5% in most cases. The critical points associated with the final accuracy of the proposed method is related to the quality of the image and the appropriate selection of the magnification factors. This method is strongly recommended to the radiation oncology centers where are no treatment planning systems available and the dose calculations are manually done. (author) 10 refs., 5 figs.

  7. NIOSH Manual of Analytical Methods (third edition). Fourth supplement

    Energy Technology Data Exchange (ETDEWEB)

    1990-08-15

    The NIOSH Manual of Analytical Methods, 3rd edition, was updated for the following chemicals: allyl-glycidyl-ether, 2-aminopyridine, aspartame, bromine, chlorine, n-butylamine, n-butyl-glycidyl-ether, carbon-dioxide, carbon-monoxide, chlorinated-camphene, chloroacetaldehyde, p-chlorophenol, crotonaldehyde, 1,1-dimethylhydrazine, dinitro-o-cresol, ethyl-acetate, ethyl-formate, ethylenimine, sodium-fluoride, hydrogen-fluoride, cryolite, sodium-hexafluoroaluminate, formic-acid, hexachlorobutadiene, hydrogen-cyanide, hydrogen-sulfide, isopropyl-acetate, isopropyl-ether, isopropyl-glycidyl-ether, lead, lead-oxide, maleic-anhydride, methyl-acetate, methyl-acrylate, methyl-tert-butyl ether, methyl-cellosolve-acetate, methylcyclohexanol, 4,4'-methylenedianiline, monomethylaniline, monomethylhydrazine, nitric-oxide, p-nitroaniline, phenyl-ether, phenyl-ether-biphenyl mixture, phenyl-glycidyl-ether, phenylhydrazine, phosphine, ronnel, sulfuryl-fluoride, talc, tributyl-phosphate, 1,1,2-trichloro-1,2,2-trifluoroethane, trimellitic-anhydride, triorthocresyl-phosphate, triphenyl-phosphate, and vinyl-acetate.

  8. Application of risk-based inspection methods for cryogenic equipment

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    Risk-based Inspection (RBI) is widely applied across the world as part of Pressure Equipment Integrity Management, especially in the oil and gas industry, to generally reduce costs compared with time-based approaches and assist in assigning resources to the most critical equipment. One of the challenges in RBI is to apply it for low temperature and cryogenic applications, as there are usually no degradation mechanisms by which to determine a suitable probability of failure in the overall risk assessment. However, the assumptions used for other degradation mechanisms can be adopted to determine, qualitatively and semi-quantitatively, a consequence of failure within the risk assessment. This can assist in providing a consistent basis for the assumptions used in ensuring adequate process safety barriers and determining suitable sizing of relief devices. This presentation will discuss risk-based inspection in the context of cryogenic safety, as well as present some of the considerations for the risk assessme...

  9. Topographic inspection as a method of weld joint diagnostic

    Czech Academy of Sciences Publication Activity Database

    Krolczyk, J.; Gapinski, B.; Krolczyk, G.; Samardžić, I.; Maruda, R. W.; Souček, Kamil; Legutko, S.; Nieslony, P.; Javadi, Y.; Staš, Lubomír

    2016-01-01

    Roč. 23, č. 1 (2016), s. 301-306 ISSN 1330-3651 R&D Projects: GA MŠk ED2.1.00/03.0082 Institutional support: RVO:68145535 Keywords : computed tomography * non-destructive techniques * topography inspection Subject RIV: JQ - Machines ; Tools Impact factor: 0.723, year: 2016 http://hrcak.srce.hr/index.php?show=clanak&id_clanak_jezik=225611

  10. Structural assessment of roof decking using visual inspection methods

    International Nuclear Information System (INIS)

    Giller, R.A.; McCoy, R.M.; Wagenblast, G.R.

    1993-01-01

    The Hanford Site has approximately 1,100 buildings, some of which date back to the early 1940s. The roof on these buildings provides a weather resisting cover as well as the load resisting structure. Past experience has been that these roof structures may have structural modifications, the weather resisting membrane may have been replaced several times, and the members may experience some type of material degradation. This material degradation has progressed to cause the collapse of some roof deck members. The intent of the Hanford Site Central Engineering roof assessment effort is to provide an expedient structural assessment of the large number of buildings at the Hanford Site. This assessment is made by qualified structural inspectors following the open-quotes Preliminary Assessmentclose quotes procedures given in the American Society of Civil Engineers (ASCE) Standard ASCE 11-90. This roof assessment effort does not provide a total qualification of the roof for the design or in-place loads. This inspection does provide a reasonable estimate of the roof loading capacity to determine if personnel access restrictions are needed. A document search and a visual walkdown inspection provide the initial screening to identify modifications and components having questionable structural integrity. The structural assessment consists of baseline dead and live load stress calculations of all roofing components based on original design material strengths. The results of these assessments are documented in a final report which is retrievable in a form that future inspections will have comparative information

  11. Structural assessment of roof decking using visual inspection methods

    International Nuclear Information System (INIS)

    Giller, R.A.; McCoy, R.M.; Wagenblast, G.R.

    1993-10-01

    The Hanford Site has approximately 1,100 buildings, some of which date back to the early 1940s. The roof on these buildings provides a weather resisting cover as well as the load resisting structure. Past experience has been that these roof structures may have structural modifications, the weather resisting membrane may have been replaced several times, and the members may experience some type of material degradation. This material degradation has progressed to cause the collapse of some roof deck members. The intent of the Hanford Site Central Engineering roof assessment effort is to provide an expedient structural assessment of the large number of buildings at the Hanford Site. This assessment is made by qualified structural inspectors following the open-quotes Preliminary Assessment close-quote procedures given in the American Society of Civil Engineers (ASCE) Standard ASCE 11-90. This roof assessment effort does not provide a total qualification of the roof for the design or in-place loads. This inspection does provide a reasonable estimate of the roof loading capacity to determine if personnel access restrictions are needed. A document search and a visual walkdown inspection provide the initial screening to identify modifications and components having questionable structural integrity. The structural assessment consists of baseline dead and live load stress calculations of all roofing components based on original design material strengths. The results of these assessments are documented in a final report which is retrievable form that future inspections will have comparative information

  12. Study on in-service inspection methods for the above-ground oil tanks floors

    Energy Technology Data Exchange (ETDEWEB)

    Min Xiong; Yewei Kang; Mingchun, Lin; Yi Sun [PetroChina Pipeline R and D Center, Langfang (China)

    2009-07-01

    It is very dangerous to the environment when oil tank floors get corrosion or leak during its long-time service. The traditional inspection methods need to shut down a tank and to empty it, then to clean it in order to inspect the floor. Comparing with the traditional methods, the in-service methods can inspect tank floors rapidly without removing product and opening the tank and can save many costs of tank emptying and cleaning. This paper explores three up-to date in-service inspection methods for the oil tank floors which are acoustic emission technology ultrasonic guided wave technology and mobile robot technology. The theoretic foundation and application status of each method is described. The advantage and disadvantage of each in-service detection technology is concluded. At last some proposals are made. (author)

  13. A Manual of Simplified Laboratory Methods for Operators of Wastewater Treatment Facilities.

    Science.gov (United States)

    Westerhold, Arnold F., Ed.; Bennett, Ernest C., Ed.

    This manual is designed to provide the small wastewater treatment plant operator, as well as the new or inexperienced operator, with simplified methods for laboratory analysis of water and wastewater. It is emphasized that this manual is not a replacement for standard methods but a guide for plants with insufficient equipment to perform analyses…

  14. Prediction method for the lubricating oil temperature of manual transaxle; Manual transaxle no yuon yosoku simulation

    Energy Technology Data Exchange (ETDEWEB)

    Iritani, M; Kaneda, K; Ibaraki, K [Toyota Central Research and Development Labs., Inc., Aichi (Japan); Suzuki, K; Morita, Y [Toyota Motor Corp., Aichi (Japan)

    1997-10-01

    Heat transfer and flow characteristics in manual transaxle (MT) are not clear. The measurement of the heat flux and the heat generations and the flow visualization were conducted for quantitative analysis of the heat transfer phenomena in the MT. A simulating technique for the lubricant temperature was developed with these experimental data and the prediction accuracy was within 3degC under the various operating conditions. The simulation was verified to be useful for estimating the lubricant temperature reduction by the lubricant volume reduction, air flow improvement around MT, etc. 7 refs., 8 figs.

  15. RIMACS, Reactor Inspection Main Control System

    International Nuclear Information System (INIS)

    2008-01-01

    1 - Description of program or function: RIMACS prepares for automatic inspection files on each inspection item for the reactor. These automatic inspection files provide the data to move RIROB (Reactor Inspection Robot) with laser by interpreting the coordinates of LASPO (Laser Positioner) and the laser detecting device of RIROB in three dimensional space. In addition, when RIROB arrives at the inspecting location, the files provide all values of the manipulator's motions to acquire the ultrasonic data. RIMACS provides various modules in order to perform these complex functions, and the functions are programmed on graphic user interface for the convenience of the user. RIMACS provides various functions, such as insertion of reactor production data, selection of the reactor for inspection, the creation of automatic inspection file, the selection of the inspection item, inspection simulation, and automatic inspection procedures. It also provides all other functions, which are necessary for the inspection, such as operating program download and manual control of LASPO and RIROB, the inspection simulation and the inspection status display by means of the graphic screen, and SODAS (ultra-Sonic Data Acquisition System) drive verification. 2 - Methods: Moving path and operation procedures for inspection robot are generated automatically with Kinematics algorithm. 3 - Restrictions on the complexity of the problem: A graphics display with MS-Window capability is required

  16. Nuclear fuel rod helium leak inspection apparatus and method

    International Nuclear Information System (INIS)

    Ahmed, H.J.

    1991-01-01

    This patent describes an inspection apparatus for testing nuclear fuel rods for helium leaks. It comprises a test chamber being openable and closable for receiving at least one nuclear fuel rod; means separate from the fuel rod for supplying helium and constantly leaking helium at a predetermined known positive value into the test chamber to constantly provide an atmosphere of helium at the predetermined known positive value in the test chamber; and means for sampling the atmosphere within the chamber and measuring the helium in the atmosphere such that a measured helium value below a preset minimum helium value substantially equal to the predetermined known positive value of the atmosphere of helium being constantly provided in the test chamber indicates a malfunction in the inspection apparatus, above a preset maximum helium value greater than the predetermined known positive in the test chamber indicates the existence of a helium leak from the fuel rod, or between the preset minimum and maximum helium values indicates the absence of a helium leak from the fuel rod

  17. Packaging supplier inspection guide

    International Nuclear Information System (INIS)

    Stromberg, H.M.; Gregg, R.E.; Kido, C.; Boyle, C.D.

    1991-05-01

    This is document is a guide for conducting quality assurance inspections of transportations packaging suppliers, where suppliers are defined as designers, fabricators, distributors, users, or owners of transportation packaging. This document can be used during an inspection to determine regulatory compliance within the requirements of 10 Code of Federal Regulations, Part 71, Subpart H (10 CFR 71.101--71.135). The guidance described in this document provides a framework for an inspection. It provides the inspector with the flexibility to adapt the methods and concepts presented here to meet the needs of the particular facility being inspected. The guide was developed to ensure a structured and consistent approach for inspections. The method treats each activity at a supplier facility as a separate entity (or functional element), and combines the activities within the framework of an ''inspection tree.'' The method separates each functional element into several areas of performance and then identifies guidelines, based on regulatory requirements, to be used to qualitatively rate each area. This document was developed to serve as a field manual to facilitate the work of inspectors. 1 ref., 1 fig., 5 tabs

  18. Improving of methods and organization of the inspection activity of The Bank of Russia

    Directory of Open Access Journals (Sweden)

    Fedulov Vladislav Igorevich

    2011-10-01

    Full Text Available The article presents information about the main causes of bank failures at present, that has been taken to find some lacks of modern organization of the Bank of Russia inspection activity. In order to eliminate the revealed lacks we supplied some methods for increasing the effectiveness of the unscheduled narrowly focused thematic inspections that are held to update opinions of supervisor about the risks and to obtain quickly reliable information about specific areas of the bank. Such an approach to organization of inspection activities is more in line with the concept of risk-focused supervision.

  19. Apparatus and method for inspecting a sealed container

    Science.gov (United States)

    Harmon, J Frank [Pocatello, ID; Jones, James L [Idaho Falls, ID; Hunt, Alan W [Pocatello, ID; Spaulding, Randy J [Pocatello, ID; Smith, Michael [Phoenix, AZ

    2009-03-24

    An apparatus for inspecting a sealed container is disclosed and which includes a pulsed electron accelerator which is positioned in spaced relation relative to a first side of the sealed container, and which produces a pulsed beam of photons which passes through the sealed container and any contents enclosed within the sealed container; a detector positioned in spaced relation relative to a second, opposite side of the sealed container, and which receives the pulsed beam of photons which passes through the contents of the sealed container, and which produces an output signal; and a computer for developing a visible image from the output signal of the detector which depicts the contents of the sealed container.

  20. A User's Manual for the NRN Shield Design Method

    Energy Technology Data Exchange (ETDEWEB)

    Hjaerne, Leif [ed.; Aalto, E; Fraeki, R; Leimdoerfer, M; Lindblom, K; Linde, S; Malen, K; Nyman, K

    1964-06-15

    This report describes a code system for bulk shield design written for a Ferranti Mercury computer and is intended as a manual for those using the programme. The idea of an 'almost direct' flux, as in the removal theory serves as a basis for further development of the theory. An important aspiration has been to minimize the manual work of administering the codes. The codes concerned are: NECO, computing necessary group constants from primary data, REFUSE and REBOX (infinite plane or cylindrical, and box geometry, respectively), computing removal flux, NEDI a one-dimensional (plane, spherical, cylindrical) diffusion multigroup code, and SALOME a Monte Carlo code computing the gamma flux. Output tapes are constructed for direct use as input tapes, when required, for a following code.

  1. A User's Manual for the NRN Shield Design Method

    International Nuclear Information System (INIS)

    Hjaerne, Leif; Aalto, E.; Fraeki, R.; Leimdoerfer, M.; Lindblom, K.; Linde, S.; Malen, K.; Nyman, K.

    1964-06-01

    This report describes a code system for bulk shield design written for a Ferranti Mercury computer and is intended as a manual for those using the programme. The idea of an 'almost direct' flux, as in the removal theory serves as a basis for further development of the theory. An important aspiration has been to minimize the manual work of administering the codes. The codes concerned are: NECO, computing necessary group constants from primary data, REFUSE and REBOX (infinite plane or cylindrical, and box geometry, respectively), computing removal flux, NEDI a one-dimensional (plane, spherical, cylindrical) diffusion multigroup code, and SALOME a Monte Carlo code computing the gamma flux. Output tapes are constructed for direct use as input tapes, when required, for a following code

  2. Validation of statistical assessment method for the optimization of the inspection need for nuclear steam generators

    International Nuclear Information System (INIS)

    Wallin, K.; Voskamp, R.; Schmibauer, J.; Ostermeyer, H.; Nagel, G.

    2011-01-01

    The cost of steam generator inspections in nuclear power plants is high. A new quantitative assessment methodology for the accumulation of flaws due to stochastic causes like fretting has been developed for cases where limited inspection data is available. Additionally, a new quantitative assessment methodology for the accumulation of environment related flaws, caused e.g. by corrosion in steam generator tubes, has been developed. The method that combines deterministic information regarding flaw initiation and growth with stochastic elements connected to environmental aspects requires only knowledge of the experimental flaw accumulation history. The method, combining both types of flaw types, provides a complete description of the flaw accumulation and there are several possible uses of the method. The method can be used to evaluate the total life expectancy of the steam generator and simple statistically defined plugging criteria can be established based on flaw behaviour. This way the inspection interval and inspection coverage can be optimized with respect to allowable flaws and the method can recognize flaw type subsets requiring more frequent inspection intervals. The method can also be used to develop statistically realistic safety factors accounting for uncertainties in inspection flaw sizing and detection. The statistical assessment method has been showed to be robust and insensitive to different assessments of plugged tubes. Because the procedure is re-calibrated after each inspection, it reacts effectively to possible changes in the steam generator environment. Validation of the assessment method is provided for real steam generators, both in the case of stochastic damage as well as environment related flaws. (authors)

  3. A Steel Ball Surface Quality Inspection Method Based on a Circumferential Eddy Current Array Sensor.

    Science.gov (United States)

    Zhang, Huayu; Xie, Fengqin; Cao, Maoyong; Zhong, Mingming

    2017-07-01

    To efficiently inspect surface defects on steel ball bearings, a new method based on a circumferential eddy current array (CECA) sensor was proposed here. The best probe configuration, in terms of the coil quality factor (Q-factor), magnetic field intensity, and induced eddy current density on the surface of a sample steel ball, was determined using 3-, 4-, 5-, and 6-coil probes, for analysis and comparison. The optimal lift-off from the measured steel ball, the number of probe coils, and the frequency of excitation current suitable for steel ball inspection were obtained. Using the resulting CECA sensor to inspect 46,126 steel balls showed a miss rate of ~0.02%. The sensor was inspected for surface defects as small as 0.05 mm in width and 0.1 mm in depth.

  4. A Steel Ball Surface Quality Inspection Method Based on a Circumferential Eddy Current Array Sensor

    Directory of Open Access Journals (Sweden)

    Huayu Zhang

    2017-07-01

    Full Text Available To efficiently inspect surface defects on steel ball bearings, a new method based on a circumferential eddy current array (CECA sensor was proposed here. The best probe configuration, in terms of the coil quality factor (Q-factor, magnetic field intensity, and induced eddy current density on the surface of a sample steel ball, was determined using 3-, 4-, 5-, and 6-coil probes, for analysis and comparison. The optimal lift-off from the measured steel ball, the number of probe coils, and the frequency of excitation current suitable for steel ball inspection were obtained. Using the resulting CECA sensor to inspect 46,126 steel balls showed a miss rate of ~0.02%. The sensor was inspected for surface defects as small as 0.05 mm in width and 0.1 mm in depth.

  5. Inspection of Nuclear Power Plant Structures - Overview of Methods and Related Applications

    International Nuclear Information System (INIS)

    Naus, Dan J.

    2009-01-01

    The objectives of this limited study were to provide an overview of the methods that are available for inspection of nuclear power plant reinforced concrete and metallic structures, and to provide an assessment of the status of methods that address inspection of thick, heavily-reinforced concrete and inaccessible areas of the containment metallic pressure boundary. In meeting these objectives a general description of nuclear power plant safety-related structures was provided as well as identification of potential degradation factors, testing and inspection requirements, and operating experience; methods for inspection of nuclear power plant reinforced concrete structures and containment metallic pressure boundaries were identified and described; and applications of nondestructive evaluation methods specifically related to inspection of thick-section reinforced concrete structures and inaccessible portions of containment metallic pressure boundaries were summarized. Recommendations are provided on utilization of test article(s) to further advance nondestructive evaluation methods related to thick-section, heavily-reinforced concrete and inaccessible portions of the metallic pressure boundary representative of nuclear power plant containments. Conduct of a workshop to provide an update on applications and needed developments for nondestructive evaluation of nuclear power plant structures would also be of benefit.

  6. Inspection of Nuclear Power Plant Structures - Overview of Methods and Related Applications

    Energy Technology Data Exchange (ETDEWEB)

    Naus, Dan J [ORNL

    2009-05-01

    The objectives of this limited study were to provide an overview of the methods that are available for inspection of nuclear power plant reinforced concrete and metallic structures, and to provide an assessment of the status of methods that address inspection of thick, heavily-reinforced concrete and inaccessible areas of the containment metallic pressure boundary. In meeting these objectives a general description of nuclear power plant safety-related structures was provided as well as identification of potential degradation factors, testing and inspection requirements, and operating experience; methods for inspection of nuclear power plant reinforced concrete structures and containment metallic pressure boundaries were identified and described; and applications of nondestructive evaluation methods specifically related to inspection of thick-section reinforced concrete structures and inaccessible portions of containment metallic pressure boundaries were summarized. Recommendations are provided on utilization of test article(s) to further advance nondestructive evaluation methods related to thick-section, heavily-reinforced concrete and inaccessible portions of the metallic pressure boundary representative of nuclear power plant containments. Conduct of a workshop to provide an update on applications and needed developments for nondestructive evaluation of nuclear power plant structures would also be of benefit.

  7. Comparison of Rice Direct Seeding Methods (Mechanical and Manual with Transplanting Method

    Directory of Open Access Journals (Sweden)

    A Eyvani

    2014-04-01

    Full Text Available The main method of rice planting in Iran is transplanting. Due to poor mechanization of rice production, this method is laborious and costly. The other method is direct seeding in wet lands which is performed in the one third of rice cultivation area of the world. The most important problem in this method is high labor requirement of weed control. In order to compare the different rice planting methods (direct drilling, transplanting, and seed broadcasting a manually operated rice direct seeder (drum seeder was designed and fabricated. The research was conducted using a randomized complete block design with three treatments and three replications. Required draft force, field efficiency, effective field capacity, yield, and yield components were measured and the treatments were compared economically. Results showed that there were significant differences among the treatments from the view point of rice yield at the confidence level of 95% i.e. the transplanting method had the maximum yield. A higher rice yield was obtained from the direct seeder compared to the manual broadcasting method but, the difference between these two methods for crop yield was not significant even at the confidence level of the 95%. The coefficient of variation of seed distribution with direct seeding was more than 20%. The labor and time requirements per hectare reduced to 7 and 20 times, respectively when comparing the newly designed direct seeder with the transplanting method. The direct seeding method had the highest benefit to cost ratio in spite of its lower yield. Therefore, this method could be recommended in the rice growing regions.

  8. A Proposal on the Quantitative Homogeneity Analysis Method of SEM Images for Material Inspections

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Song Hyun; Kim, Jong Woo; Shin, Chang Ho [Hanyang University, Seoul (Korea, Republic of); Choi, Jung-Hoon; Cho, In-Hak; Park, Hwan Seo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    A scanning electron microscope (SEM) is a method to inspect the surface microstructure of materials. The SEM uses electron beams for imaging high magnifications of material surfaces; therefore, various chemical analyses can be performed from the SEM images. Therefore, it is widely used for the material inspection, chemical characteristic analysis, and biological analysis. For the nuclear criticality analysis field, it is an important parameter to check the homogeneity of the compound material for using it in the nuclear system. In our previous study, the SEM was tried to use for the homogeneity analysis of the materials. In this study, a quantitative homogeneity analysis method of SEM images is proposed for the material inspections. The method is based on the stochastic analysis method with the information of the grayscales of the SEM images.

  9. A Proposal on the Quantitative Homogeneity Analysis Method of SEM Images for Material Inspections

    International Nuclear Information System (INIS)

    Kim, Song Hyun; Kim, Jong Woo; Shin, Chang Ho; Choi, Jung-Hoon; Cho, In-Hak; Park, Hwan Seo

    2015-01-01

    A scanning electron microscope (SEM) is a method to inspect the surface microstructure of materials. The SEM uses electron beams for imaging high magnifications of material surfaces; therefore, various chemical analyses can be performed from the SEM images. Therefore, it is widely used for the material inspection, chemical characteristic analysis, and biological analysis. For the nuclear criticality analysis field, it is an important parameter to check the homogeneity of the compound material for using it in the nuclear system. In our previous study, the SEM was tried to use for the homogeneity analysis of the materials. In this study, a quantitative homogeneity analysis method of SEM images is proposed for the material inspections. The method is based on the stochastic analysis method with the information of the grayscales of the SEM images

  10. Validity of a manual soft tissue profile prediction method following mandibular setback osteotomy.

    Science.gov (United States)

    Kolokitha, Olga-Elpis

    2007-10-01

    The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication.

  11. Qualification of UT methods and systems used for in-service inspections of VVER 440 vessels

    International Nuclear Information System (INIS)

    Skala, Z.; Vit, J.

    2003-01-01

    SKODA JS has been performing automated in-service inspections VVER reactor pressure vessels for more than twenty years. All of these inspections were performed by ultrasonic pulse echo method, combined from 1996 with eddy current testing. The Time of Flight Diffraction Method (TOFD) is one of modern methods of ultrasonic testing. The accuracy of sizing the through wall extent of a flaw by TOFD is much better than the accuracy achievable by the pulse echo method. A series of laboratory tests were performed by SKODA JS and confirmed the suitability of TOFD method for VVER reactor parts testing. The Czech Atomic law demands the qualification of systems and methods used for the in-service inspections of nuclear reactors. The qualification is done in accordance with ENIQ methodology and consists of preparation of the Technical Justification and practical tests made under the surveillance of Qualification Body. SKODA JS intends to qualify systems and methods used for the automated ultrasonic testing of VVER 440 and VVER 1000 reactor components from the inner as well as from the outer surface. The accuracy of the flaw through wall extent sizing by TOFD was confirmed by the qualification of methods and systems used for the testing of VVER 440 vessel circumferential weld and so the TOFD method shall be used routinely by SKODA JS for the inspection of vessel circumferential welds root area and for sizing of flaws exceeding the acceptance level. (author)

  12. A method for visual inspection of welding by means of image processing of x-ray photograph

    International Nuclear Information System (INIS)

    Koshimizu, Hiroyasu; Yoshida, Tohru.

    1983-01-01

    Computer image processing is becoming a helpful tool even in industrial inspections. A computerized method for welding visual inspection is proposed in this paper. This method is based on computer image processing of X-ray photograph of welding, in which the appearance information of weldments such as shape of weld bead really exists. Structural patterns are extracted at first and seven computer measures for inspection are calculated using those patterns. Software system for visual inspection is constructed based on these seven measures. It was experimentally made clear that this system can provide a performance of more than 0.85 correlation to human visual inspection. As a result, the visual inspection by computer using X-ray photograph became a promising tool to realize objectivity and quantitativity of welding inspection. Additionally, the consistency of the system, the possibility to reduce computing costs, and so on are discussed to improve the proposed method. (author)

  13. New concepts, requirements and methods concerning the periodic inspection of the CANDU fuel channels

    International Nuclear Information System (INIS)

    Denis, J.R.

    1995-01-01

    Periodic inspection of fuel channels is essential for a proper assessment of the structural integrity of these vital components of the reactor. The development of wet channel technologies for non-destructive examination (NDE) of pressure tubes and the high technical performance and reliability of the CIGAR equipment have led, in less than 1 0 years, to the accumulation of a very significant volume of data concerning the flaw mechanisms and structural behaviour of the CANDU fuel channels. On this basis, a new form of the CAN/CSA-N285.4 Standard for Periodic Inspection of CANDU Nuclear Power Plant components was elaborated, introducing new concepts and requirements, in accord with the powerful NDE methods now available. This paper presents these concepts and requirements, and discusses the NDE methods, presently used or under development, to satisfy these requirements. Specific features regarding the fuel channel inspections of Cernavoda NGS Unit 1 are also discussed. (author)

  14. METHOD AND APPARATUS FOR INSPECTION OF COMPRESSED DATA PACKAGES

    DEFF Research Database (Denmark)

    2008-01-01

    to be transferred over the data network. The method comprises the steps of: a) extracting payload data from the payload part of the package, b) appending the extracted payload data to a stream of data, c) probing the data package header so as to determine the compression scheme that is applied to the payload data...

  15. Evaluation of Contamination Inspection and Analysis Methods through Modeling System Performance

    Science.gov (United States)

    Seasly, Elaine; Dever, Jason; Stuban, Steven M. F.

    2016-01-01

    Contamination is usually identified as a risk on the risk register for sensitive space systems hardware. Despite detailed, time-consuming, and costly contamination control efforts during assembly, integration, and test of space systems, contaminants are still found during visual inspections of hardware. Improved methods are needed to gather information during systems integration to catch potential contamination issues earlier and manage contamination risks better. This research explores evaluation of contamination inspection and analysis methods to determine optical system sensitivity to minimum detectable molecular contamination levels based on IEST-STD-CC1246E non-volatile residue (NVR) cleanliness levels. Potential future degradation of the system is modeled given chosen modules representative of optical elements in an optical system, minimum detectable molecular contamination levels for a chosen inspection and analysis method, and determining the effect of contamination on the system. By modeling system performance based on when molecular contamination is detected during systems integration and at what cleanliness level, the decision maker can perform trades amongst different inspection and analysis methods and determine if a planned method is adequate to meet system requirements and manage contamination risk.

  16. Autonomy and manual operation in a small robotic system for under-vehicle inspections at security checkpoints

    Science.gov (United States)

    Smuda, William; Muench, Paul L.; Gerhart, Grant R.; Moore, Kevin L.

    2002-07-01

    Unmanned ground vehicle (UGV) technology can be used in a number of ways to assist in counter-terrorism activities. In addition to the conventional uses of tele-operated robots for unexploded ordinance handling and disposal, water cannons and other crowd control devices, robots can also be employed for a host of terrorism deterrence and detection applications. In previous research USU developed a completely autonomous prototype robot for performing under- vehicle inspections in parking areas (ODIS). Testing of this prototype and discussions with the user community indicated that neither the technology nor the users are ready for complete autonomy. In this paper we present a robotic system based on ODIS that balances the users' desire/need for tele- operation with a limited level of autonomy that enhances the performance of the robot. The system can be used by both civilian law enforcement and military police to replace the traditional mirror on a stick system of looking under cars for bombs and contraband.

  17. An evaluation of methods assessing the physical demands of manual lifting in scaffolding

    NARCIS (Netherlands)

    Beek, van der A.J.; Mathiassen, S.E.; Windhorst, J.; Burdorf, A.

    2005-01-01

    Four methods assessing the physical demands of manual lifting were compared. The scaffolding job was evaluated and three distinct scaffolding tasks were ranked using: (1) the revised NIOSH lifting equation (NIOSH method), (2) lifting guidelines for the Dutch construction industry (Arbouw method),

  18. 1H MR spectroscopy of the normal human brains : comparison of automated prescan method with manual method

    International Nuclear Information System (INIS)

    Lim, Myung Kwan; Suh, Chang Hae; Cho, Young Kook; Kim, Jin Hee

    1998-01-01

    The purpose of this paper is to evaluate regional differences in relative metabolite ratios in the normal human brain by 1 H MR spectroscopy (MRS), and compare the spectral quality obtained by the automated prescan method (PROBE) and the manual method. A total of 61 reliable spectra were obtained by PROBE (28/34=82% success) and by the manual method (33/33=100% success). Regional differences in the spectral patterns of the five regions were clearly demonstrated by both PROBE and the manual methods. for prescanning, the manual method took slightly longer than PROBE (3-5 mins and 2 mins, respectively). There were no significant differences in spectral patterns and relative metabolic ratios between the two methods. However, auto-prescan by PROBE seemed to be very vulnerable to slight movement by patients, and in three cases, an acceptable spectrum was thus not obtained. PROBE is a highly practical and reliable method for single voxel 1 H MRS of the human brain; the two methods of prescanning do not result in significantly different spectral patterns and the relative metabolite ratios. PROBE, however, is vulnerable to slight movement by patients, and if the success rate for obtaining quality spectra is to be increased, regardless of the patient's condition and the region of the brain, it must be used in conjunction with the manual method. (author). 23 refs., 2 tabs., 3 figs

  19. Inspection Mechanism and Experimental Study of Prestressed Reverse Tension Method under PC Beam Bridge Anchorage

    Science.gov (United States)

    Peng, Zhang

    2018-03-01

    the prestress under anchorage is directly related to the structural security and performance of PC beam bridge. The reverse tension method is a kind of inspection which confirms the prestress by exerting reversed tension load on the exposed prestressing tendon of beam bridge anchoring system. The thesis elaborately expounds the inspection mechanism and mechanical effect of reverse tension method, theoretically analyzes the influential elements of inspection like tool anchorage deformation, compression of conjuncture, device glide, friction of anchorage loop mouth and elastic compression of concrete, and then presents the following formula to calculate prestress under anchorage. On the basis of model experiment, the thesis systematically studies some key issues during the reverse tension process of PC beam bridge anchorage system like the formation of stress-elongation curve, influential factors, judgment method of prestress under anchorage, variation trend and compensation scale, verifies the accuracy of mechanism analysis and demonstrates: the prestress under anchorage is less than or equal to 75% of the ultimate strength of prestressing tendon, the error of inspect result is less than 1%, which can meet with the demands of construction. The research result has provided theoretical basis and technical foundation for the promotion and application of reverse tension in bridge construction.

  20. Comparison of urine analysis using manual and sedimentation methods.

    Science.gov (United States)

    Kurup, R; Leich, M

    2012-06-01

    Microscopic examination of urine sediment is an essential part in the evaluation of renal and urinary tract diseases. Traditionally, urine sediments are assessed by microscopic examination of centrifuged urine. However the current method used by the Georgetown Public Hospital Corporation Medical Laboratory involves uncentrifuged urine. To encourage high level of care, the results provided to the physician must be accurate and reliable for proper diagnosis. The aim of this study is to determine whether the centrifuge method is more clinically significant than the uncentrifuged method. In this study, a comparison between the results obtained from centrifuged and uncentrifuged methods were performed. A total of 167 urine samples were randomly collected and analysed during the period April-May 2010 at the Medical Laboratory, Georgetown Public Hospital Corporation. The urine samples were first analysed microscopically by the uncentrifuged, and then by the centrifuged method. The results obtained from both methods were recorded in a log book. These results were then entered into a database created in Microsoft Excel, and analysed for differences and similarities using this application. Analysis was further done in SPSS software to compare the results using Pearson ' correlation. When compared using Pearson's correlation coefficient analysis, both methods showed a good correlation between urinary sediments with the exception of white bloods cells. The centrifuged method had a slightly higher identification rate for all of the parameters. There is substantial agreement between the centrifuged and uncentrifuged methods. However the uncentrifuged method provides for a rapid turnaround time.

  1. Application of risk-based methods for inspection of nuclear power plant components

    International Nuclear Information System (INIS)

    Balkey, K.R.

    1992-01-01

    In-service inspections (ISIs) can play a significant role in minimizing equipment and structural failures. All aspects of inspections, i.e., objectives, method, timing, and the acceptance criteria for detected flaws can affect the probability of component failure. Where ISI programs exist, they are primarily based on prior experience and engineering judgment. At best, some include an implicit consideration of risk (probability of failure multiplied by consequence). Since late 1988, a multidisciplined American Society of Mechanical Engineers (ASME) Research Task Force on Risk-Based Inspection Guidelines has been addressing the general question of how to formally incorporate risk considerations into plans and requirements for the ISI of components and structural systems. The task force and steering committee that guided the project have concluded that appropriate analytical methods exist for evaluating and quantifying risks associated with pressure boundary and structural failures. With the support of about a dozen industry and government organizations, the research group has recommended a general methodology for establishing a risk-based inspection program that could be applied to any nuclear system or structural system

  2. ACARP Project C10059. ACARP manual of modern coal testing methods. Volume 2: Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Sakurovs, R.; Creelman, R.; Pohl, J.; Juniper, L. [CSIRO Energy Technology, Sydney, NSW (Australia)

    2002-07-01

    The Manual summarises the purpose, applicability, and limitations of a range of standard and modern coal testing methods that have potential to assist the coal company technologist to better evaluate coal performance. It is presented in two volumes. This second volume provides more detailed information regarding the methods discussed in Volume 1.

  3. Methods for the Determination of Chemical Contaminants in Drinking Water. Training Manual.

    Science.gov (United States)

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual, intended for chemists and technicians with little or no experience in chemical procedures required to monitor drinking water, covers analytical methods for inorganic and organic chemical contaminants listed in the interim primary drinking water regulations. Topics include methods for heavy metals, nitrate, and organic…

  4. Experiments of Long-range Inspection Method in Straight Pipes using Ultrasonic Guided Waves

    International Nuclear Information System (INIS)

    Eom, H. S.; Lim, S. H.; Kim, J. H.; Joo, Y.S.

    2006-02-01

    This report describes experimental results of a long-range inspection method of pipes using ultrasonic guided waves. In chapter 2, theory of guided wave was reviewed. In chapter 3, equipment and procedures which were used in the experiments were described. Detailed specifications of the specimens described in chapter 4. In chapter 5, we analyzed characteristics of guided wave signals according to shapes and sizes of defects and presents results of various signal processing methods

  5. Diagnostic Value of Manual and Computerized Methods of Dental Casts Analysis

    Directory of Open Access Journals (Sweden)

    H. Rahimi

    2009-06-01

    Full Text Available Objective: The aim of this study was to evaluate the validity of computerized and manual methods of dental cast analysis.Materials and Methods: Twenty set-ups of upper and lower casts using artificial teeth corresponding to various malocclusions were created for a diagnostic in vitro study. Values of tooth size were calculated from the isolated artificial teeth out of the set-ups, results were considered as a gold standard for the tooth size. Arch width was calculated from the existing set-ups on the dentins.Impressions were taken of the casts with alginate and duplicated with dental stone. Models were measured with digital caliper manually. Then images were taken from the occlusal views of the casts by a digital camera. Measurements were done on digital images with the AutoCAD software.The results of the computerized and manual methods were compared with the gold standard.Intra class correlation coefficient of reliability was used to measure the accuracy ofthe methods and the Friedman technique used to evaluate the significance of differences.Results: Results indicated that all measurements were highly correlated, e.g. gold standard and manual (0.9613-0.9991, gold standard and computerized (0.7118-0.9883, manual and computerized (0.6734-0.9914. Statistically significant differences were present between these methods (P<0.05, but they proved not to be clinically significant.Conclusion: Manual measurement is still the most accurate method when compared to the computerized measurements and the results of measurement by computer should be interpreted with caution.

  6. Computerization of Hungarian reforestation manual with machine learning methods

    Science.gov (United States)

    Czimber, Kornél; Gálos, Borbála; Mátyás, Csaba; Bidló, András; Gribovszki, Zoltán

    2017-04-01

    Hungarian forests are highly sensitive to the changing climate, especially to the available precipitation amount. Over the past two decades several drought damages were observed for tree species which are in the lower xeric limit of their distribution. From year to year these affected forest stands become more difficult to reforest with the same native species because these are not able to adapt to the increasing probability of droughts. The climate related parameter set of the Hungarian forest stand database needs updates. Air humidity that was formerly used to define the forest climate zones is not measured anymore and its value based on climate model outputs is highly uncertain. The aim was to develop a novel computerized and objective method to describe the species-specific climate conditions that is essential for survival, growth and optimal production of the forest ecosystems. The method is expected to project the species spatial distribution until 2100 on the basis of regional climate model simulations. Until now, Hungarian forest managers have been using a carefully edited spreadsheet for reforestation purposes. Applying binding regulations this spreadsheet prescribes the stand-forming and admixed tree species and their expected growth rate for each forest site types. We are going to present a new machine learning based method to replace the former spreadsheet. We took into great consideration of various methods, such as maximum likelihood, Bayesian networks, Fuzzy logic. The method calculates distributions, setups classification, which can be validated and modified by experts if necessary. Projected climate change conditions makes necessary to include into this system an additional climate zone that does not exist in our region now, as well as new options for potential tree species. In addition to or instead of the existing ones, the influence of further limiting parameters (climatic extremes, soil water retention) are also investigated. Results will be

  7. ANSI/ASHRAE/IES Standard 90.1-2010 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-05-01

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1- 2010 (Standard 90.1-2010).The PRM is used for rating the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM. It should be noted that this document is created independently from ASHRAE and SSPC 90.1 and is not sanctioned nor approved by either of those entities . Potential users of this manual include energy modelers, software developers and implementers of “beyond code” energy programs. Energy modelers using ASHRAE Standard 90.1-2010 for beyond code programs can use this document as a reference manual for interpreting requirements of the Performance Rating method. Software developers, developing tools for automated creation of the baseline model can use this reference manual as a guideline for developing the rules for the baseline model.

  8. Comparison of manual and automated quantification methods of 123I-ADAM

    International Nuclear Information System (INIS)

    Kauppinen, T.; Keski-Rahkonen, A.; Sihvola, E.; Helsinki Univ. Central Hospital

    2005-01-01

    123 I-ADAM is a novel radioligand for imaging of the brain serotonin transporters (SERTs). Traditionally, the analysis of brain receptor studies has been based on observer-dependent manual region of interest definitions and visual interpretation. Our aim was to create a template for automated image registrations and volume of interest (VOI) quantification and to show that an automated quantification method of 123 I-ADAM is more repeatable than the manual method. Patients, methods: A template and a predefined VOI map was created from 123 I-ADAM scans done for healthy volunteers (n=15). Scans of another group of healthy persons (HS, n=12) and patients with bulimia nervosa (BN, n=10) were automatically fitted to the template and specific binding ratios (SBRs) were calculated by using the VOI map. Manual VOI definitions were done for the HS and BN groups by both one and two observers. The repeatability of the automated method was evaluated by using the BN group. Results: For the manual method, the interobserver coefficient of repeatability was 0.61 for the HS group and 1.00 for the BN group. The intra-observer coefficient of repeatability for the BN group was 0.70. For the automated method, the coefficient of repeatability was 0.13 for SBRs in midbrain. Conclusion: An automated quantification gives valuable information in addition to visual interpretation decreasing also the total image handling time and giving clear advantages for research work. An automated method for analysing 123 I-ADAM binding to the brain SERT gives repeatable results for fitting the studies to the template and for calculating SBRs, and could therefore replace manual methods. (orig.)

  9. Comparison of manual and automated quantification methods of {sup 123}I-ADAM

    Energy Technology Data Exchange (ETDEWEB)

    Kauppinen, T. [Helsinki Univ. Central Hospital (Finland). HUS Helsinki Medical Imaging Center; Helsinki Univ. Central Hospital (Finland). Division of Nuclear Medicine; Koskela, A.; Ahonen, A. [Helsinki Univ. Central Hospital (Finland). Division of Nuclear Medicine; Diemling, M. [Hermes Medical Solutions, Stockholm (Sweden); Keski-Rahkonen, A.; Sihvola, E. [Helsinki Univ. (Finland). Dept. of Public Health; Helsinki Univ. Central Hospital (Finland). Dept. of Psychiatry

    2005-07-01

    {sup 123}I-ADAM is a novel radioligand for imaging of the brain serotonin transporters (SERTs). Traditionally, the analysis of brain receptor studies has been based on observer-dependent manual region of interest definitions and visual interpretation. Our aim was to create a template for automated image registrations and volume of interest (VOI) quantification and to show that an automated quantification method of {sup 123}I-ADAM is more repeatable than the manual method. Patients, methods: A template and a predefined VOI map was created from {sup 123}I-ADAM scans done for healthy volunteers (n=15). Scans of another group of healthy persons (HS, n=12) and patients with bulimia nervosa (BN, n=10) were automatically fitted to the template and specific binding ratios (SBRs) were calculated by using the VOI map. Manual VOI definitions were done for the HS and BN groups by both one and two observers. The repeatability of the automated method was evaluated by using the BN group. Results: For the manual method, the interobserver coefficient of repeatability was 0.61 for the HS group and 1.00 for the BN group. The intra-observer coefficient of repeatability for the BN group was 0.70. For the automated method, the coefficient of repeatability was 0.13 for SBRs in midbrain. Conclusion: An automated quantification gives valuable information in addition to visual interpretation decreasing also the total image handling time and giving clear advantages for research work. An automated method for analysing {sup 123}I-ADAM binding to the brain SERT gives repeatable results for fitting the studies to the template and for calculating SBRs, and could therefore replace manual methods. (orig.)

  10. VARIABILITY OF MANUAL AND COMPUTERIZED METHODS FOR MEASURING CORONAL VERTEBRAL INCLINATION IN COMPUTED TOMOGRAPHY IMAGES

    Directory of Open Access Journals (Sweden)

    Tomaž Vrtovec

    2015-06-01

    Full Text Available Objective measurement of coronal vertebral inclination (CVI is of significant importance for evaluating spinal deformities in the coronal plane. The purpose of this study is to systematically analyze and compare manual and computerized measurements of CVI in cross-sectional and volumetric computed tomography (CT images. Three observers independently measured CVI in 14 CT images of normal and 14 CT images of scoliotic vertebrae by using six manual and two computerized measurements. Manual measurements were obtained in coronal cross-sections by manually identifying the vertebral body corners, which served to measure CVI according to the superior and inferior tangents, left and right tangents, and mid-endplate and mid-wall lines. Computerized measurements were obtained in two dimensions (2D and in three dimensions (3D by manually initializing an automated method in vertebral centroids and then searching for the planes of maximal symmetry of vertebral anatomical structures. The mid-endplate lines were the most reproducible and reliable manual measurements (intra- and inter-observer variability of 0.7° and 1.2° standard deviation, SD, respectively. The computerized measurements in 3D were more reproducible and reliable (intra- and inter-observer variability of 0.5° and 0.7° SD, respectively, but were most consistent with the mid-wall lines (2.0° SD and 1.4° mean absolute difference. The manual CVI measurements based on mid-endplate lines and the computerized CVI measurements in 3D resulted in the lowest intra-observer and inter-observer variability, however, computerized CVI measurements reduce observer interaction.

  11. Quality assurance manual plutonium liquid scintillation methods and procedures

    International Nuclear Information System (INIS)

    Romero, L.

    1997-01-01

    Nose swipe analysis is a very important tool for Radiation Protection personnel. Nose swipe analysis is a very fast and accurate method for (1) determining if a worker has been exposed to airborne plutonium contamination and (2) Identifying the area where there has been a possible plutonium release. Liquid scintillation analysis techniques have been effectively applied to accurately determine the plutonium alpha activity on nose swipe media. Whatman-40 paper and Q-Tips are the only two media which have been evaluated and can be used for nose swipe analysis. Presently, only Q-Tips are used by Group HSE-1 Radiation Protection Personnel. However, both swipe media will be discussed in this report

  12. Infrared thermography inspection methods applied to the target elements of W7-X divertor

    Energy Technology Data Exchange (ETDEWEB)

    Missirlian, M. [Association Euratom-CEA, CEA/DSM/DRFC, CEA/Cadarache, F-13108 Saint Paul Lez Durance (France)], E-mail: marc.missirlian@cea.fr; Traxler, H. [PLANSEE SE, Technology Center, A-6600 Reutte (Austria); Boscary, J. [Max-Planck-Institut fuer Plasmaphysik, Euratom Association, Boltzmannstr. 2, D-85748 Garching (Germany); Durocher, A.; Escourbiac, F.; Schlosser, J. [Association Euratom-CEA, CEA/DSM/DRFC, CEA/Cadarache, F-13108 Saint Paul Lez Durance (France); Schedler, B.; Schuler, P. [PLANSEE SE, Technology Center, A-6600 Reutte (Austria)

    2007-10-15

    The non-destructive examination (NDE) method is one of the key issues in developing highly loaded plasma-facing components (PFCs) for a next generation fusion devices such as W7-X and ITER. The most critical step is certainly the fabrication and the examination of the bond between the armour and the heat sink. Two inspection systems based on the infrared thermography methods, namely, the transient thermography (SATIR-CEA) and the pulsed thermography (ARGUS-PLANSEE), are being developed and have been applied to the pre-series of target elements of the W7-X divertor. Results obtained from qualification experiences performed on target elements with artificial calibrated defects allowed to demonstrate the capability of the two techniques and raised the efficiency of inspection to a level which is appropriate for industrial application.

  13. Infrared thermography inspection methods applied to the target elements of W7-X divertor

    International Nuclear Information System (INIS)

    Missirlian, M.; Traxler, H.; Boscary, J.; Durocher, A.; Escourbiac, F.; Schlosser, J.; Schedler, B.; Schuler, P.

    2007-01-01

    The non-destructive examination (NDE) method is one of the key issues in developing highly loaded plasma-facing components (PFCs) for a next generation fusion devices such as W7-X and ITER. The most critical step is certainly the fabrication and the examination of the bond between the armour and the heat sink. Two inspection systems based on the infrared thermography methods, namely, the transient thermography (SATIR-CEA) and the pulsed thermography (ARGUS-PLANSEE), are being developed and have been applied to the pre-series of target elements of the W7-X divertor. Results obtained from qualification experiences performed on target elements with artificial calibrated defects allowed to demonstrate the capability of the two techniques and raised the efficiency of inspection to a level which is appropriate for industrial application

  14. Diagnosis of porcine enzootic pneumonia by post mortem sanitary inspection: comparison with other diagnostic methods

    Directory of Open Access Journals (Sweden)

    Kênia de Fátima Carrijo

    2014-06-01

    Full Text Available ABSTRACT. Carrijo K.F., Nascimento E.R., Pereira V.L.A., Morés N., Klein, C.S., Domingues L.M. & Tortelly R. [Diagnosis of porcine enzootic pneumonia by post mortem sanitary inspection: comparison with other diagnostic methods.] Diagnóstico da pneumonia enzoótica suína pela inspeção sanitária post mortem: comparação com outros métodos de diagnóstico. Revista Brasileira de Veterinária Brasileira 36(2:188-194, 2014. Faculdade de Medicina Veterinária, Universidade Federal de Uberlândia, Av. Pará, 1720, Bloco 2T, Jardim Umuarama, Uberlândia, MG 38400-902, Brasil. E-mail: keniacarrijo@ famev.ufu.br To compare the concordance of the diagnosis of porcine enzootic pneumonia (PEP by post-mortem Sanitary Inspection with other methods (histophatology and immunohistochemistry - IHC, were used lung tissue samples from 100 pigs slaughtered under sanitary inspection, and 50 of these had macroscopic lesions suggestive of PEP and 50 had no such lesions. These were fixed in 10% buffered formalin and processed by routine procedures for paraffin embedding and IHC technique for Mycoplasma hyopneumoniae using a monoespecific polyclonal antibody. The study demonstrating that there is concordance between the diagnosis of Sanitary Inspection with histophatology, between the diagnosis of Sanitary Inspection with IHC and histophatology with IHC. It can be conclude that when the lung has gross lesions of PEP, the probability the result is positive to M. hyopneumoniae by IHC and the presence of microscopic lesions increases. Thus, the microscopic diagnosis for PEP is feasible because it is associated to the other, so that the diagnosis given by the officials of Sanitary Inspection in slaughterhouses is not wrong; the macroscopic diagnosis is therefore a valid method for the diagnosis of PEP, it being understood this is not to say that the detection of M. hyopneumoniae.

  15. Manual herbicide application methods for managing vegetation in Appalachian hardwood forests

    Science.gov (United States)

    Jeffrey D. Kochenderfer; James N. Kochenderfer; Gary W. Miller

    2012-01-01

    Four manual herbicide application methods are described for use in Appalachian hardwood forests. Stem injection, basal spray, cut-stump, and foliar spray techniques can be used to control interfering vegetation and promote the development of desirable reproduction and valuable crop trees in hardwood forests. Guidelines are presented to help the user select the...

  16. Validity of a Manual Soft Tissue Profile Prediction Method Following Mandibular Setback Osteotomy

    OpenAIRE

    Kolokitha, Olga-Elpis

    2007-01-01

    Objectives The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. Methods To test the validity of the manu...

  17. Comparison of manual & automated analysis methods for corneal endothelial cell density measurements by specular microscopy.

    Science.gov (United States)

    Huang, Jianyan; Maram, Jyotsna; Tepelus, Tudor C; Modak, Cristina; Marion, Ken; Sadda, SriniVas R; Chopra, Vikas; Lee, Olivia L

    2017-08-07

    To determine the reliability of corneal endothelial cell density (ECD) obtained by automated specular microscopy versus that of validated manual methods and factors that predict such reliability. Sharp central images from 94 control and 106 glaucomatous eyes were captured with Konan specular microscope NSP-9900. All images were analyzed by trained graders using Konan CellChek Software, employing the fully- and semi-automated methods as well as Center Method. Images with low cell count (input cells number <100) and/or guttata were compared with the Center and Flex-Center Methods. ECDs were compared and absolute error was used to assess variation. The effect on ECD of age, cell count, cell size, and cell size variation was evaluated. No significant difference was observed between the Center and Flex-Center Methods in corneas with guttata (p=0.48) or low ECD (p=0.11). No difference (p=0.32) was observed in ECD of normal controls <40 yrs old between the fully-automated method and manual Center Method. However, in older controls and glaucomatous eyes, ECD was overestimated by the fully-automated method (p=0.034) and semi-automated method (p=0.025) as compared to manual method. Our findings show that automated analysis significantly overestimates ECD in the eyes with high polymegathism and/or large cell size, compared to the manual method. Therefore, we discourage reliance upon the fully-automated method alone to perform specular microscopy analysis, particularly if an accurate ECD value is imperative. Copyright © 2017. Published by Elsevier España, S.L.U.

  18. Semiautomated segmentation of blood vessels using ellipse-overlap criteria: Method and comparison to manual editing

    International Nuclear Information System (INIS)

    Shiffman, Smadar; Rubin, Geoffrey D.; Schraedley-Desmond, Pamela; Napel, Sandy

    2003-01-01

    Two-dimensional intensity-based methods for the segmentation of blood vessels from computed-tomography-angiography data often result in spurious segments that originate from other objects whose intensity distributions overlap with those of the vessels. When segmented images include spurious segments, additional methods are required to select segments that belong to the target vessels. We describe a method that allows experts to select vessel segments from sequences of segmented images with little effort. Our method uses ellipse-overlap criteria to differentiate between segments that belong to different objects and are separated in plane but are connected in the through-plane direction. To validate our method, we used it to extract vessel regions from volumes that were segmented via analysis of isolabel-contour maps, and showed that the difference between the results of our method and manually-edited results was within inter-expert variability. Although the total editing duration for our method, which included user-interaction and computer processing, exceeded that of manual editing, the extent of user interaction required for our method was about a fifth of that required for manual editing

  19. ASSESSMENT OF CERAMIC TILE FROST RESISTANCE BY MEANS OF THE FREQUENCY INSPECTION METHOD

    Directory of Open Access Journals (Sweden)

    MICHAL MATYSÍK

    2011-06-01

    Full Text Available The paper presents some results of our experimental analysis of ceramic cladding element frost resistance, particular attention being paid to the application of the frequency inspection method. Three different sets of ceramic tiles of the Ia class to EN 14 411 B standard made by various manufacturers have been analyzed. The ceramic tiles under investigation have been subjected to freeze-thaw-cycle-based degradation in compliance with the relevant ČSN EN ISO 10545-12 standard. Furthermore, accelerated degradation procedure has been applied to selected test specimens, consisting in reducing the temperature of water soaked ceramic tiles in the course of the degradation cycles down –70°C. To verify the correctness of the frequency inspection results, additional physical properties of the ceramic tiles under test have been measured, such as, the ceramic tile strength limit, modulus of elasticity and modulus of deformability, resulting from the flexural tensile strength tests, integrity defect and surface micro-geometry tracking. It has been proved that the acoustic method of frequency inspection is a sensitive indicator of the structure condition and can be applied to the ceramic cladding element frost resistance and service life prediction assessment.

  20. Application of risk-informed methods to in-service piping inspection in Framatome type nuclear power plants

    International Nuclear Information System (INIS)

    Kim, Jin Hoi; Lee, Jeong Seok; Yun, Eun Sub

    2014-01-01

    The Pressurized water reactor owners group (PWROG) developed and applied a risk-informed in-service inspection (RI-ISI) program, as an alternative to the existing ASME Section XI sampling inspection method. The RI-ISI programs enhance overall safety by focusing inspections of piping at high safety significance (HSS) locations where failure mechanisms are likely to be present. Additionally, the RI-ISI program can reduce nondestructive evaluation (NDE) exams, man-rem exposure for inspectors, and inspection time, among other benefits. The RI-ISI method of in-service piping inspection was applied to 3 units (KSNPs: Korea standard nuclear power plants) and is being deployed to the other units. In this paper, the results of RI-ISI for a Framatome type (France CPI) nuclear power plant are presented. It was concluded that application of RI-ISI to the plant could enhance and maintain plant safety, as well as provide the benefits of greater reliability.

  1. A study of drying and cleaning methods used in preparation for fluorescent penetrant inspection - Part II

    International Nuclear Information System (INIS)

    Brasche, L.; Lopez, R.; Larson, B.

    2003-01-01

    Fluorescent penetrant inspection is the most widely used method for aerospace components such as critical rotating components of gas turbine engines. Successful use of FPI begins with a clean and dry part, followed by a carefully controlled and applied FPI process, and conscientious inspection by well trained personnel. A variety of cleaning methods are in use for cleaning of titanium and nickel parts with selection based on the soils or contamination to be removed. Cleaning methods may include chemical or mechanical methods with sixteen different types studied as part of this program. Several options also exist for use in drying parts prior to FPI. Samples were generated and exposed to a range of conditions to study the effect of both drying and cleaning methods on the flaw response of FPI. Low cycle fatigue (LCF) cracks were generated in approximately 40 nickel and 40 titanium samples for evaluation of the various cleaning methods. Baseline measurements were made for each of the samples using a photometer to measure sample brightness and a UVA videomicroscope to capture digital images of the FPI indications. Samples were exposed to various contaminants, cleaned and inspected. Brightness measurements and digital images were also taken to compare to the baseline data. A comparison of oven drying to flash dry in preparation for FPI has been completed and will be reported in Part I. Comparison of the effectiveness of various cleaning methods for the contaminants will be presented in Part II. The cleaning and drying studies were completed in cooperation with Delta Airlines using cleaning, drying and FPI processes typical of engine overhaul processes and equipment. The work was completed as part of the Engine Titanium Consortium and included investigators from Honeywell, General Electric, Pratt and Whitney, and Rolls Royce

  2. A study of drying and cleaning methods used in preparation for fluorescent penetrant inspection - Part I

    International Nuclear Information System (INIS)

    Brasche, L.; Lopez, R.; Larson, B.

    2003-01-01

    Fluorescent penetrant inspection is the most widely used method for aerospace components such as critical rotating components of gas turbine engines. Successful use of FPI begins with a clean and dry part, followed by a carefully controlled and applied FPI process, and conscientious inspection by well trained personnel. A variety of cleaning methods are in use for cleaning of titanium and nickel parts with selection based on the soils or contamination to be removed. Cleaning methods may include chemical or mechanical methods with sixteen different types studied as part of this program. Several options also exist for use in drying parts prior to FPI. Samples were generated and exposed to a range of conditions to study the effect of both drying and cleaning methods on the flaw response of FPI. Low cycle fatigue (LCF) cracks were generated in approximately 40 nickel and 40 titanium samples for evaluation of the various cleaning methods. Baseline measurements were made for each of the samples using a photometer to measure sample brightness and a UVA videomicroscope to capture digital images of the FPI indications. Samples were exposed to various contaminants, cleaned and inspected. Brightness measurements and digital images were also taken to compare to the baseline data. A comparison of oven drying to flash dry in preparation for FPI has been completed and will be reported in Part I. Comparison of the effectiveness of various cleaning methods for the contaminants will be presented in Part II. The cleaning and drying studies were completed in cooperation with Delta Airlines using cleaning, drying and FPI processes typical of engine overhaul processes and equipment. The work was completed as part of the Engine Titanium Consortium and included investigators from Honeywell, General Electric, Pratt and Whitney, and Rolls Royce

  3. Evaluation of the eddy-current method for the inspection of steam generator tubing: denting

    International Nuclear Information System (INIS)

    Brown, S.D.; Flora, J.H.

    1977-01-01

    Continued evaluation of existing eddy-current in-service inspection (ISI) methods for steam generator tubing has emphasized the effects of denting. Denting is a circumferential deformation of the tube in the support region as a result of the formation of a magnetite, Fe 3 O 4 , corrosion product on the carbon steel tube support plate in the crevice between the support plate and the tube wall. The effects of denting on eddy current inspection are twofold: (1) The detection and measurement of defects in the dented region is hampered by the distortion of the eddy-current response signals caused by the dents and (2) large dents may prevent the passage of high fill factor probes forcing the inspection teams to use a smaller probe in undented regions. Unless appropriate measures are taken, less reliable detection of defects and estimation of their depth can result. The report presents an experimental evaluation of existing eddy-current ISI methods when used to inspect dented regions. Tubes were mechanically dented to simulate various degrees of service induced denting. These tubes were then inserted in carbon steel tube support plates and the crevice region between the support plate and tube was subsequently packed with powdered magnetite. Diametral dent sizes considered during this program varied between 1 and 10 mils. Eddy-current signal patterns and strip chart recordings were obtained using a variety of test parameters, such as frequency, phase rotation and coil configuration, on tube samples containing various degrees of denting and with several types of defects in the dented system

  4. Probability of Detection Study to Assess the Performance of Nondestructive Inspection Methods for Wind Turbine Blades.

    Energy Technology Data Exchange (ETDEWEB)

    Roach, Dennis P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Rice, Thomas M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Paquette, Joshua [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Wind turbine blades pose a unique set of inspection challenges that span from very thick and attentive spar cap structures to porous bond lines, varying core material and a multitude of manufacturing defects of interest. The need for viable, accurate nondestructive inspection (NDI) technology becomes more important as the cost per blade, and lost revenue from downtime, grows. NDI methods must not only be able to contend with the challenges associated with inspecting extremely thick composite laminates and subsurface bond lines, but must also address new inspection requirements stemming from the growing understanding of blade structural aging phenomena. Under its Blade Reliability Collaborative program, Sandia Labs quantitatively assessed the performance of a wide range of NDI methods that are candidates for wind blade inspections. Custom wind turbine blade test specimens, containing engineered defects, were used to determine critical aspects of NDI performance including sensitivity, accuracy, repeatability, speed of inspection coverage, and ease of equipment deployment. The detection of fabrication defects helps enhance plant reliability and increase blade life while improved inspection of operating blades can result in efficient blade maintenance, facilitate repairs before critical damage levels are reached and minimize turbine downtime. The Sandia Wind Blade Flaw Detection Experiment was completed to evaluate different NDI methods that have demonstrated promise for interrogating wind blades for manufacturing flaws or in-service damage. These tests provided the Probability of Detection information needed to generate industry-wide performance curves that quantify: 1) how well current inspection techniques are able to reliably find flaws in wind turbine blades (industry baseline) and 2) the degree of improvements possible through integrating more advanced NDI techniques and procedures. _____________ S a n d i a N a t i o n a l L a b o r a t o r i e s i s a m u l t i

  5. Ultrasonic inspection

    International Nuclear Information System (INIS)

    Satittada, Gannaga

    1984-01-01

    Ultrasonic inspection is one of the most widely used methods for nondestructive inspection. The beam of high-frequency sound wave, ultrasonic wave, is introduced into the material. It travels through the material with some attendant loss of energy and can be reflected at interfaces. The reflected beam is detected and analyzed. Ultrasonic inspection is used to detect flaws in metal parts as well as in welded, brazed and bonded joints during research work and developing production and service. It is also used to detect and locate porosity, pipe, and flakes. In addition, it can be used for the measurement of metal thickness. Ultrasonic inspection is therefore used for quality control and material inspection in all major industries

  6. A real-time visual inspection method of fastening bolts in freight car operation

    Science.gov (United States)

    Nan, Guo; Yao, JunEn

    2015-10-01

    A real-time inspection of the key components is necessary for ensuring safe operation of freight car. While traditional inspection depends on the trained human inspectors, which is time-consuming and lower efficient. With the development of machine vision, vision-based inspection methods get more railway on-spot applications. The cross rod end fastening bolts are important components on both sides of the train body that fixing locking plates together with the freight car main structure. In our experiment, we get the images containing fastening bolt components, and accurately locate the locking plate position using a linear Support Vector Machine (SVM) locating model trained with Histograms of Oriented Gradients (HOG) features. Then we extract the straight line segment using the Line Segment Detector (LSD) and encoding them in a range, which constitute a straight line segment dataset. Lastly we determine the locking plate's working state by the linear pattern. The experiment result shows that the localization accurate rate is over 99%, the fault detection rate is over 95%, and the module implementation time is 2f/s. The overall performance can completely meet the practical railway safety assurance application.

  7. Corrosion Assessment by Using Risk-Based Inspection Method for Petrochemical Plant - Practical Experience

    International Nuclear Information System (INIS)

    Choi, Song Chun; Song, Ki Hun

    2009-01-01

    Corrosion assessment has a number of uses but the use considered here is as a precursor to Risk-Based Inspection (RBI) planning. Systematic methods consisting of technical modules of RBI program were used to assess the effect of specific corrosion mechanism on the probability of failure in equipment of petrochemical plants. Especially in part of the damage and corrosion assessment, screening step involved evaluating the combinations of process conditions and construction materials for each equipment item in order to determine which damage mechanisms are potentially active. For general internal corrosion, either API 510 or API 570 was applied as the damage rate in the calculation to determine the remaining life and inspection frequency. In some cases, a measured rate of corrosion may not be available. The technical modules of RBI program employ default values for corrosion, typically derived from published data or from experience with similar processes, for use until inspection results are available. This paper describes the case study of corrosion and damage assessment by using RBI methodology in petrochemical plant. Specifically, this paper reports the methodology and the results of its application to the petrochemical units using the KGS-RBI TM program, developed by the Korea Gas Safety Corporation to suit Korean situation in conformity with API 581 Codes

  8. Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Survey

    Science.gov (United States)

    Arbogast, Belinda F.

    1996-01-01

    The analytical methods validated by the Mineral Resource Surveys Program, Geologic Division, is the subject of this manual. This edition replaces the methods portion of Open-File Report 90-668 published in 1990. Newer methods may be used which have been approved by the quality assurance (QA) project and are on file with the QA coordinator.This manual is intended primarily for use by laboratory scientists; this manual can also assist laboratory users to evaluate the data they receive. The analytical methods are written in a step by step approach so that they may be used as a training tool and provide detailed documentation of the procedures for quality assurance. A "Catalog of Services" is available for customer (submitter) use with brief listings of:the element(s)/species determined,method of determination,reference to cite,contact person,summary of the technique,and analyte concentration range.For a copy please contact the Branch office at (303) 236-1800 or fax (303) 236-3200.

  9. INSPECT: a package of computer programs for planning and evaluating safeguards inspections

    International Nuclear Information System (INIS)

    Mullen, M.F.

    1980-01-01

    As part of the US Program of Technical Assistance to IAEA Safeguards, PNL has developed a package of computer programs, called INSPECT, that can be used in planning and evaluating safeguards inspections of various types of nuclear facilities. The programs are based on the statistical methods described in Part F of the IAEA Safeguards Technical Manual and can be used to calculate the variance components of the MUF (Material Unaccounted For) statistic, the variance components of the D (difference) statistic, attribute and variables sampling plans, and a measure of the effectiveness of the inspection plan. The paper describes the programs, reviews a number of applications, and indicates areas for future work

  10. MARS code manual volume I: code structure, system models, and solution methods

    International Nuclear Information System (INIS)

    Chung, Bub Dong; Kim, Kyung Doo; Bae, Sung Won; Jeong, Jae Jun; Lee, Seung Wook; Hwang, Moon Kyu; Yoon, Churl

    2010-02-01

    Korea Advanced Energy Research Institute (KAERI) conceived and started the development of MARS code with the main objective of producing a state-of-the-art realistic thermal hydraulic systems analysis code with multi-dimensional analysis capability. MARS achieves this objective by very tightly integrating the one dimensional RELAP5/MOD3 with the multi-dimensional COBRA-TF codes. The method of integration of the two codes is based on the dynamic link library techniques, and the system pressure equation matrices of both codes are implicitly integrated and solved simultaneously. In addition, the Equation-Of-State (EOS) for the light water was unified by replacing the EOS of COBRA-TF by that of the RELAP5. This theory manual provides a complete list of overall information of code structure and major function of MARS including code architecture, hydrodynamic model, heat structure, trip / control system and point reactor kinetics model. Therefore, this report would be very useful for the code users. The overall structure of the manual is modeled on the structure of the RELAP5 and as such the layout of the manual is very similar to that of the RELAP. This similitude to RELAP5 input is intentional as this input scheme will allow minimum modification between the inputs of RELAP5 and MARS3.1. MARS3.1 development team would like to express its appreciation to the RELAP5 Development Team and the USNRC for making this manual possible

  11. Cervical spine motion in manual versus Jackson table turning methods in a cadaveric global instability model.

    Science.gov (United States)

    DiPaola, Matthew J; DiPaola, Christian P; Conrad, Bryan P; Horodyski, MaryBeth; Del Rossi, Gianluca; Sawers, Andrew; Bloch, David; Rechtine, Glenn R

    2008-06-01

    A study of spine biomechanics in a cadaver model. To quantify motion in multiple axes created by transfer methods from stretcher to operating table in the prone position in a cervical global instability model. Patients with an unstable cervical spine remain at high risk for further secondary injury until their spine is adequately surgically stabilized. Previous studies have revealed that collars have significant, but limited benefit in preventing cervical motion when manually transferring patients. The literature proposes multiple methods of patient transfer, although no one method has been universally adopted. To date, no study has effectively evaluated the relationship between spine motion and various patient transfer methods to an operating room table for prone positioning. A global instability was surgically created at C5-6 in 4 fresh cadavers with no history of spine pathology. All cadavers were tested both with and without a rigid cervical collar in the intact and unstable state. Three headrest permutations were evaluated Mayfield (SM USA Inc), Prone View (Dupaco, Oceanside, CA), and Foam Pillow (OSI, Union City, CA). A trained group of medical staff performed each of 2 transfer methods: the "manual" and the "Jackson table" transfer. The manual technique entailed performing a standard rotation of the supine patient on a stretcher to the prone position on the operating room table with in-line manual cervical stabilization. The "Jackson" technique involved sliding the supine patient to the Jackson table (OSI, Union City, CA) with manual in-line cervical stabilization, securing them to the table, then initiating the table's lock and turn mechanism and rotating them into a prone position. An electromagnetic tracking device captured angular motion between the C5 and C6 vertebral segments. Repeated measures statistical analysis was performed to evaluate the following conditions: collar use (2 levels), headrest (3 levels), and turning technique (2 levels). For all

  12. Development of Wall Thinning Distinction Method using the Multi-inspecting UT Data of Carbon Steel Piping

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Kyeong Mo; Yun, Hun; Lee, Chan Kyoo [KEPCO E and C, Yongin (Korea, Republic of)

    2012-05-15

    To manage the wall thinning of carbon steel piping in nuclear power plants, the utility of Korea has performed thickness inspection for some quantity of pipe components during refueling outages and determined whether repair or replacement after evaluating UT (Ultrasonic Test) data. When the existing UT data evaluation methods, such as Band, Blanket, PTP (Point to Point) Methods, are applied to a certain pipe component, unnecessary re-inspecting situations may be generated even though the component does not thinned. In those cases, economical loss caused by repeated inspection and problems of maintaining the pipe integrity followed by decreasing of newly inspected components may be generated. EPRI (Electric Power Research Institute) in USA has suggested several statistical methods, TPM (Total Point Method), LSS (Least Square Slope) Method, etc. to distinguish whether multiple inspecting components have thinned or not. This paper presents the analysis results for multiple inspecting components over three times based on both NAM (Near Area of Minimum) Method developed by KEPCO-E and C and the other methods suggested by EPRI.

  13. Annual Net Ecosystem Productivity of Wetlands: A Comparison of Automated and Manual Chamber Methods

    Science.gov (United States)

    Burrows, E. H.; Bubier, J. L.; Mosedale, A.; Crill, P. M.

    2001-05-01

    Net Ecosystem Exchange (NEE) of carbon dioxide (CO2) was measured in a minerotrophic poor fen in southeastern New Hampshire during the 2000 growing season using two types of chamber methods. Instantaneous CO2 flux was measured with transparent lexan and teflon static climate controlled chambers by calculating the change in headspace CO2 concentration in the chamber over time. Once per week the flux was sampled from ten manually operated chambers using a LI-COR 6200 portable photosynthesis system, which included a LI-6250 infrared gas analyzer, connected to the chambers. Ten automated chambers were installed in May of 2000, sampling CO2 flux every three hours over the diurnal cycle using a LI-COR 6262 infrared gas analyzer. The chambers and collars were placed throughout the fen in order to sample the range of plant communities. The manual sampling was done during the middle of the day, but the rate of photosynthesis changes depending on the amount of photosynthetically active radiation (PAR). In order to simulate varying light levels, shrouds blocking different amounts of light were placed over each manual chamber. An opaque shroud was used to measure respiration. NEE ranged from -13.0 to 12.5 μ mol CO2/m2/s in the manual chambers and -16.2 to 11.8 μ mol CO2/m2/s in the automated chambers for the mid-summer growing season. Manual respiration fluxes were measured under higher temperature regimes and the response of respiration to temperature will be factored in when comparing the two chamber techniques. Research during the summer of 2001 will also include diurnal measurements. Growing season net ecosystem productivity (NEP) will be estimated and compared for the two chamber systems. Several models will be used to estimate the flux when the manual chambers were not being sampled. The models will be based on biomass and dominant species in each chamber, and various environmental factors including water table, pH, relative humidity, PAR, air and peat temperature

  14. Vision and Control for UAVs: A Survey of General Methods andof Inexpensive Platforms for Infrastructure Inspection

    Directory of Open Access Journals (Sweden)

    Koppány Máthé

    2015-06-01

    Full Text Available Unmanned aerial vehicles (UAVs have gained significant attention in recent years. Low-cost platforms using inexpensive sensor payloads have been shown to provide satisfactory flight and navigation capabilities. In this report, we survey vision and control methods that can be applied to low-cost UAVs, and we list some popular inexpensive platforms and application fields where they are useful. We also highlight the sensor suites used where this information is available. We overview, among others, feature detection and tracking, optical flow and visual servoing, low-level stabilization and high-level planning methods. We then list popular low-cost UAVs, selecting mainly quadrotors. We discuss applications, restricting our focus to the field of infrastructure inspection. Finally, as an example, we formulate two use-cases for railway inspection, a less explored application field, and illustrate the usage of the vision and control techniques reviewed by selecting appropriate ones to tackle these use-cases. To select vision methods, we run a thorough set of experimental evaluations.

  15. IAEA safeguards technical manual

    International Nuclear Information System (INIS)

    1980-02-01

    The necessity for statistical inference procedures arises because of time and cost limitations imposed on inspection activities, and also because of inherent limitations of inspection measurement instruments and techniques. This manual produces statistical concepts and techniques in the field of nuclear material control

  16. Non-destructive Inspection of Top-Down Construction Joints of Column in SRC Structure using Ultrasonic Method

    International Nuclear Information System (INIS)

    Park, Seok Kyun; Baek, Un Chan; Lee, Han Bum; Kim, Myoung Mo

    2000-01-01

    The joint treatment of concrete is one of the technical problems in top down construction method. Joints created with the top down construction result in serious weakness from the aspects of both structural and water-barrier function. Ultrasonic method was used for the inspection of top down construction joints of a various column in SRC structure in this study. The advantages and limitations of this method for non-destructive inspection in top down construction joints are investigated. As a result, it has been verified that the semi-direct measurement method is more effective than the other methods for detecting the voids of construction joints using ultrasonic method

  17. SRC-I demonstration plant analytical laboratory methods manual. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Klusaritz, M.L.; Tewari, K.C.; Tiedge, W.F.; Skinner, R.W.; Znaimer, S.

    1983-03-01

    This manual is a compilation of analytical procedures required for operation of a Solvent-Refined Coal (SRC-I) demonstration or commercial plant. Each method reproduced in full includes a detailed procedure, a list of equipment and reagents, safety precautions, and, where possible, a precision statement. Procedures for the laboratory's environmental and industrial hygiene modules are not included. Required American Society for Testing and Materials (ASTM) methods are cited, and ICRC's suggested modifications to these methods for handling coal-derived products are provided.

  18. Solutions manual to accompany An introduction to numerical methods and analysis

    CERN Document Server

    Epperson, James F

    2014-01-01

    A solutions manual to accompany An Introduction to Numerical Methods and Analysis, Second Edition An Introduction to Numerical Methods and Analysis, Second Edition reflects the latest trends in the field, includes new material and revised exercises, and offers a unique emphasis on applications. The author clearly explains how to both construct and evaluate approximations for accuracy and performance, which are key skills in a variety of fields. A wide range of higher-level methods and solutions, including new topics such as the roots of polynomials, sp

  19. Endotracheal tube cuff pressure monitoring during neurosurgery - Manual vs. automatic method

    Directory of Open Access Journals (Sweden)

    Mukul Kumar Jain

    2011-01-01

    Full Text Available Background: Inflation and assessment of the endotracheal tube cuff pressure is often not appreciated as a critical aspect of endotracheal intubation. Appropriate endotracheal tube cuff pressure, endotracheal intubation seals the airway to prevent aspiration and provides for positive-pressure ventilation without air leak. Materials and Methods: Correlations between manual methods of assessing the pressure by an experienced anesthesiologists and assessment with maintenance of the pressure within the normal range by the automated pressure controller device were studied in 100 patients divided into two groups. In Group M, endotracheal tube cuff was inflated manually by a trained anesthesiologist and checked for its pressure hourly by cuff pressure monitor till the end of surgery. In Group C, endotracheal tube cuff was inflated by automated cuff pressure controller and pressure was maintained at 25-cm H 2 O throughout the surgeries. Repeated measure ANOVA was applied. Results: Repeated measure ANOVA results showed that average of endotracheal tube cuff pressure of 50 patients taken at seven different points is significantly different (F-value: 171.102, P-value: 0.000. Bonferroni correction test shows that average of endotracheal tube cuff pressure in all six groups are significantly different from constant group (P = 0.000. No case of laryngomalacia, tracheomalacia, tracheal stenosis, tracheoesophageal fistula or aspiration pneumonitis was observed. Conclusions: Endotracheal tube cuff pressure was significantly high when endotracheal tube cuff was inflated manually. The known complications of high endotracheal tube cuff pressure can be avoided if the cuff pressure controller device is used and manual methods cannot be relied upon for keeping the pressure within the recommended levels.

  20. The Alaska Commercial Fisheries Water Quality Sampling Methods and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Folley, G.; Pearson, L.; Crosby, C. [Alaska Dept. of Environmental Conservation, Soldotna, AK (United States); DeCola, E.; Robertson, T. [Nuka Research and Planning Group, Seldovia, AK (United States)

    2006-07-01

    A comprehensive water quality sampling program was conducted in response to the oil spill that occurred when the M/V Selendang Ayu ship ran aground near a major fishing port at Unalaska Island, Alaska in December 2004. In particular, the sampling program focused on the threat of spilled oil to the local commercial fisheries resources. Spill scientists were unable to confidently model the movement of oil away from the wreck because of limited oceanographic data. In order to determine which fish species were at risk of oil contamination, a real-time assessment of how and where the oil was moving was needed, because the wreck became a continual source of oil release for several weeks after the initial grounding. The newly developed methods and procedures used to detect whole oil during the sampling program will be presented in the Alaska Commercial Fisheries Water Quality Sampling Methods and Procedures Manual which is currently under development. The purpose of the manual is to provide instructions to spill managers while they try to determine where spilled oil has or has not been encountered. The manual will include a meaningful data set that can be analyzed in real time to assess oil movement and concentration. Sections on oil properties and processes will be included along with scientific water quality sampling methods for whole and dissolved phase oil to assess potential contamination of commercial fishery resources and gear in Alaska waters during an oil spill. The manual will present a general discussion of factors that should be considered when designing a sampling program after a spill. In order to implement Alaska's improved seafood safety measures, the spatial scope of spilled oil must be known. A water quality sampling program can provide state and federal fishery managers and food safety inspectors with important information as they identify at-risk fisheries. 11 refs., 7 figs.

  1. Simple heuristics: A bridge between manual core design and automated optimization methods

    International Nuclear Information System (INIS)

    White, J.R.; Delmolino, P.M.

    1993-01-01

    The primary function of RESCUE is to serve as an aid in the analysis and identification of feasible loading patterns for LWR reload cores. The unique feature of RESCUE is that its physics model is based on some recent advances in generalized perturbation theory (GPT) methods. The high order GPT techniques offer the accuracy, computational efficiency, and flexibility needed for the implementation of a full range of capabilities within a set of compatible interactive (manual and semi-automated) and automated design tools. The basic design philosophy and current features within RESCUE are reviewed, and the new semi-automated capability is highlighted. The online advisor facility appears quite promising and it provides a natural bridge between the traditional trial-and-error manual process and the recent progress towards fully automated optimization sequences. (orig.)

  2. ANSI/ASHRAE/IES Standard 90.1-2016 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Eley, Charles [Eley and Associates, Hobe Sound, FL (United States)

    2017-09-29

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1-2016 (Standard 90.1-2016). The PRM can be used to demonstrate compliance with the standard and to rate the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. Use of the PRM for demonstrating compliance with Standard 90.1 is a new feature of the 2016 edition. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM.

  3. NDT method in determining the rate of corrosion applicable to risk based inspection

    International Nuclear Information System (INIS)

    Mohamed Hairul Hasmoni; Mohamad Pauzi Ismail; Ab Razak Hamzah

    2004-01-01

    Corrosion is a major problem in oil and gas industries, refineries and chemical process plants as the equipment is often exposed to corrosive environments or elevated temperature. Important equipment need to operate safely and reliably to avoid injuries to personnel and the public, and to prevent loss time and cost incurred due to loss of production and shutdown. The paper assess the approach in evaluating the technique of non-destructive testing (NDT) using Ultrasonic Testing (UT) in determining the rate of corrosion and remaining life of equipment applicable to Risk Based Inspection (RBI). Methods in determining the corrosion rate are presented using analytical method. Examples and data from MINT chiller water pipeline are presented to illustrate the application of these methods. (Author)

  4. A Novel Defect Inspection Method for Semiconductor Wafer Based on Magneto-Optic Imaging

    Science.gov (United States)

    Pan, Z.; Chen, L.; Li, W.; Zhang, G.; Wu, P.

    2013-03-01

    The defects of semiconductor wafer may be generated from the manufacturing processes. A novel defect inspection method of semiconductor wafer is presented in this paper. The method is based on magneto-optic imaging, which involves inducing eddy current into the wafer under test, and detecting the magnetic flux associated with eddy current distribution in the wafer by exploiting the Faraday rotation effect. The magneto-optic image being generated may contain some noises that degrade the overall image quality, therefore, in this paper, in order to remove the unwanted noise present in the magneto-optic image, the image enhancement approach using multi-scale wavelet is presented, and the image segmentation approach based on the integration of watershed algorithm and clustering strategy is given. The experimental results show that many types of defects in wafer such as hole and scratch etc. can be detected by the method proposed in this paper.

  5. Agreement Between Visual Inspection with Acetic Acid and Papanicolaous Smear as Screening Methods for Cervical Cancer

    International Nuclear Information System (INIS)

    Naz, U.; Hanif, S.

    2014-01-01

    Objective: To determine degree of agreement between visual inspection with acetic acid (VIA) and Papanicolaous (Pap) smear as screening methods for cervical cancer. Study Design: A cross-sectional study. Place and Duration of Study: Department of Obstetrics and Gynaecology, Sir Ganga Ram Hospital, Lahore, from July to December 2012. Methodology: Two hundred and fifty women in reproductive age group presenting with various gynaecological complaints were included in the study. A Papanicolaous smear was taken and visual inspection with 5% acetic acid was done. VIA was reported as positive or negative according to acetowhite changes and cytology result was graded as CIN 1, 2, 3 and squamous carcinoma. Those women who showed positive result with either VIA or Pap smear or both were further subjected to colposcopic directed biopsy which was taken as gold standard. Results were computed using Statistical Package for Social Sciences (SPSS) version 16 and statistical test used was kappa. Results: Out of 250 women, VIA was positive in 55 (22%) patients and Pap smear was abnormal in 27 (10.8%). Histological diagnosis of CIN/cancer was made in 36 out of a total 62 patients who underwent biopsy. Conclusion: There was a fair agreement between VIA and Pap smear, with VIA detecting more abnormalities than cytology. In the absence of Pap smear availability, VIA may be a reasonable cervical cancer screening method, especially in low resource settings. (author)

  6. Weld quality inspection using laser-EMAT ultrasonic system and C-scan method

    Science.gov (United States)

    Yang, Lei; Ume, I. Charles

    2014-02-01

    Laser/EMAT ultrasonic technique has attracted more and more interests in weld quality inspection because of its non-destructive and non-contact characteristics. When ultrasonic techniques are used to detect welds joining relative thin plates, the dominant ultrasonic waves present in the plates are Lamb waves, which propagate all through the thickness. Traditional Time of Flight(ToF) method loses its power. The broadband nature of laser excited ultrasound plus dispersive and multi-modal characteristic of Lamb waves make the EMAT acquired signals very complicated in this situation. Challenge rises in interpreting the received signals and establishing relationship between signal feature and weld quality. In this paper, the laser/EMAT ultrasonic technique was applied in a C-scan manner to record full wave propagation field over an area close to the weld. Then the effect of weld defect on the propagation field of Lamb waves was studied visually by watching an movie resulted from the recorded signals. This method was proved to be effective to detect the presence of hidden defect in the weld. Discrete wavelet transform(DWT) was applied to characterize the acquired ultrasonic signals and ideal band-pass filter was used to isolate wave components most sensitive to the weld defect. Different interactions with the weld defect were observed for different wave components. Thus this C-Scan method, combined with DWT and ideal band-pass filter, proved to be an effective methodology to experimentally study interactions of various laser excited Lamb Wave components with weld defect. In this work, the method was demonstrated by inspecting a hidden local incomplete penetration in weld. In fact, this method can be applied to study Lamb Wave interactions with any type of structural inconsistency. This work also proposed a ideal filtered based method to effectively reduce the total experimental time.

  7. Noble Gas Sampling and Detection Methods for On-Site Inspections in Support of CTBT

    International Nuclear Information System (INIS)

    Wieslander, J.S.E.

    2015-01-01

    The On-Site Inspections (OSI) constitutes the final verification measure under the CTBT, and are conducted to verify States Parties' compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT). An on-site inspection is launched to establish whether or not a nuclear explosion has been carried out and during such an inspection, facts might also be gathered to identify a possible violator of the Treaty. The Treaty lists all activities and techniques that are permitted and one of these is the environmental sampling of noble gases (NG) in the air and underground, which can be deployed at any time during an OSI. The CTBT relevant isotopes are Xe-133, 133m, 131m, 135 and Ar-37. The samples are primarily to be analyzed on-site, although the treaty also allows off-site analysis in designated laboratories if necessary. Stringent procedures ensure the security, integrity and confidentiality of the samples throughout the sampling and analysis process — all taking place in the field. Over the past decade the techniques for NG sampling, processing and analysis of both atmospheric and subsoil NG samples have been developed further in order to fit to the conditions and requirements during an OSI. This has been a major international effort with a global set of collaborators. Especially during the past three years the efforts intensified in order to finalize the scientific and technical developments for the Integrated Field Exercise, November 2014 (IFE14). This presentation will provide an overview of the current status of the OSI NG sampling regime and the OSI NG Field Laboratory to be deployed in IFE14, together with more technical descriptions of methods and equipment as well as a short discussion on potential future developments and alternative applications as applicable. (author)

  8. The impact of type of manual medication cart filling method on the frequency of medication administration errors : A prospective before and after study

    NARCIS (Netherlands)

    Schimmel, Anneliene M.; Becker, Matthijs L.; van den Bout, Tilly; Taxis, Katja; van den Bemt, Patricia M. L. A.

    Background: The medication cart can be filled using an automated system or a manual method and when using a manual method the medication can be arranged either by round time or by medication name. For the manual methods, it is hypothesized that the latter method would result in a lower frequency of

  9. FURNACE; a toroidal geometry neutronic program system method description and users manual

    International Nuclear Information System (INIS)

    Verschuur, K.A.

    1984-12-01

    The FURNACE program system performs neutronic and photonic calculations in 3D toroidal geometry for application to fusion reactors. The geometry description is quite general, allowing any torus cross section and any neutron source density distribution for the plasma, as well as simple parametric representations of circular, elliptic and D-shaped tori and plasmas. The numerical method is based on an approximate transport model that produces results with sufficient accuracy for reactor-design purposes, at acceptable calculational costs. A short description is given of the numerical method, and a user manual for the programs of the system: FURNACE, ANISN-PT, LIBRA, TAPEMA and DRAWER is presented

  10. A comparison of coronal mass ejections identified by manual and automatic methods

    Directory of Open Access Journals (Sweden)

    S. Yashiro

    2008-10-01

    Full Text Available Coronal mass ejections (CMEs are related to many phenomena (e.g. flares, solar energetic particles, geomagnetic storms, thus compiling of event catalogs is important for a global understanding these phenomena. CMEs have been identified manually for a long time, but in the SOHO era, automatic identification methods are being developed. In order to clarify the advantage and disadvantage of the manual and automatic CME catalogs, we examined the distributions of CME properties listed in the CDAW (manual and CACTus (automatic catalogs. Both catalogs have a good agreement on the wide CMEs (width>120° in their properties, while there is a significant discrepancy on the narrow CMEs (width≤30°: CACTus has a larger number of narrow CMEs than CDAW. We carried out an event-by-event examination of a sample of events and found that the CDAW catalog have missed many narrow CMEs during the solar maximum. Another significant discrepancy was found on the fast CMEs (speed>1000 km/s: the majority of the fast CDAW CMEs are wide and originate from low latitudes, while the fast CACTus CMEs are narrow and originate from all latitudes. Event-by-event examination of a sample of events suggests that CACTus has a problem on the detection of the fast CMEs.

  11. Comparison of manual versus automated data collection method for an evidence-based nursing practice study.

    Science.gov (United States)

    Byrne, M D; Jordan, T R; Welle, T

    2013-01-01

    The objective of this study was to investigate and improve the use of automated data collection procedures for nursing research and quality assurance. A descriptive, correlational study analyzed 44 orthopedic surgical patients who were part of an evidence-based practice (EBP) project examining post-operative oxygen therapy at a Midwestern hospital. The automation work attempted to replicate a manually-collected data set from the EBP project. Automation was successful in replicating data collection for study data elements that were available in the clinical data repository. The automation procedures identified 32 "false negative" patients who met the inclusion criteria described in the EBP project but were not selected during the manual data collection. Automating data collection for certain data elements, such as oxygen saturation, proved challenging because of workflow and practice variations and the reliance on disparate sources for data abstraction. Automation also revealed instances of human error including computational and transcription errors as well as incomplete selection of eligible patients. Automated data collection for analysis of nursing-specific phenomenon is potentially superior to manual data collection methods. Creation of automated reports and analysis may require initial up-front investment with collaboration between clinicians, researchers and information technology specialists who can manage the ambiguities and challenges of research and quality assurance work in healthcare.

  12. Ground Snow Measurements: Comparisons of the Hotplate, Weighing and Manual Methods

    Science.gov (United States)

    Wettlaufer, A.; Snider, J.; Campbell, L. S.; Steenburgh, W. J.; Burkhart, M.

    2015-12-01

    The Yankee Environmental Systems (YES) Hotplate was developed to avoid some of the problems associated with weighing snowfall sensors. This work compares Hotplate, weighing sensor (ETI NOAH-II) and manual measurements of liquid-equivalent depth. The main field site was at low altitude in western New York; Hotplate and ETI comparisons were also made at two forested subalpine sites in southeastern Wyoming. The manual measurement (only conducted at the New York site) was derived by weighing snow cores sampled from a snow board. The two recording gauges (Hotplate and ETI) were located within 5 m of the snow board. Hotplate-derived accumulations were corrected using a wind-speed dependent catch efficiency and the ETI orifice was heated and alter shielded. Three important findings are evident from the comparisons: 1) The Yes-derived accumulations, recorded in a user-accessible file, were compared to accumulations derived using an in-house calibration and fundamental measurements (plate power, long and shortwave radiances, wind speed, and temperature). These accumulations are highly correlated (N=24; r2=0.99), but the YES-derived values are larger by 20%. 2) The in-house Hotplate accumulations are in good agreement with ETI-based accumulations but with larger variability (N=24; r2=0.88). 3) The comparison of in-house Hotplate accumulation versus manual accumulation, expressed as mm of liquid, exhibits a fitted linear relationship Y (in-house) versus X (manual) given by Y = -0.2 (±1.4) + 0.9 (±0.1) · X (N= 20; r2=0.89). Thus, these two methods agree within statistical uncertainty.

  13. Infrared thermography inspection methods applied to the target elements of W7-X Divertor

    International Nuclear Information System (INIS)

    Missirlian, M.; Durocher, A.; Schlosser, J.; Farjon, J.-L.; Vignal, N.; Traxler, H.; Schedler, B.; Boscary, J.

    2006-01-01

    As heat exhaust capability and lifetime of plasma-facing component (PFC) during in-situ operation are linked to the manufacturing quality, a set of non-destructive testing must be operated during R-and-D and manufacturing phases. Within this framework, advanced non-destructive examination (NDE) methods are one of the key issues to achieve a high level of quality and reliability of joining techniques in the production of high heat flux components but also to develop and built successfully PFCs for a next generation of fusion devices. In this frame, two NDE infrared thermographic approaches, which have been recently applied to the qualification of CFC target elements of the W7-X divertor during the first series production will be discussed in this paper. The first one, developed by CEA (SATIR facility) and used with successfully to the control of the mass-produced actively cooled PFCs on Tore Supra, is based on the transient thermography where the testing protocol consists in inducing a thermal transient within the heat sink structure by an alternative hot/cold water flow. The second one, recently developed by PLANSEE (ARGUS facility), is based on the pulsed thermography where the component is heated externally by a single powerful flash of light. Results obtained on qualification experiences performed during the first series production of W7-X divertor components representing about thirty mock-ups with artificial and manufacturing defects, demonstrated the capabilities of these two methods and raised the efficiency of inspection to a level which is appropriate for industrial application. This comparative study, associated to a cross-checking analysis between the high heat flux performance tests and these inspection methods by infrared thermography, showed a good reproducibility and allowed to set a detectable limit specific at each method. Finally, the detectability of relevant defects showed excellent coincidence with thermal images obtained from high heat flux

  14. No-cost manual method for preparation of tissue microarrays having high quality comparable to semiautomated methods.

    Science.gov (United States)

    Foda, Abd Al-Rahman Mohammad

    2013-05-01

    Manual tissue microarray (TMA) construction had been introduced to avoid the high cost of automated and semiautomated techniques. The cheapest and simplest technique for constructing manual TMA was that of using mechanical pencil tips. This study was carried out to modify this method, aiming to raise its quality to reach that of expensive ones. Some modifications were introduced to Shebl's technique. Two conventional mechanical pencil tips of different diameters were used to construct the recipient blocks. A source of mild heat was used, and blocks were incubated at 38°C overnight. With our modifications, 3 high-density TMA blocks were constructed. We successfully performed immunostaining without substantial tissue loss. Our modifications increased the number of cores per block and improved the stability of the cores within the paraffin block. This new, modified technique is a good alternative for expensive machines in many laboratories.

  15. Application of non-destructive testing and in-service inspections to research reactors and preparation of ISI programme and manual for WWR-C research reactors

    International Nuclear Information System (INIS)

    Khattab, M.

    1996-01-01

    The present report gives a review on the results of application of non-destructive testing and in-service inspections to WWR-C reactors in different countries. The major problems related to reactor safety and the procedure of inspection techniques are investigated to collect the experience gained from this type of reactors. Exchangeable experience in solving common problems in similar reactors play an important role in the effectiveness of their rehabilitation programmes. 9 figs., 4 tabs

  16. Quality assurance inspections for shipping and storage containers

    Energy Technology Data Exchange (ETDEWEB)

    Stromberg, H.M.; Roberts, G.D.; Bryce, J.H. [Lockheed Idaho Technologies Co., Idaho Falls, ID (United States)

    1996-04-01

    This is a guide for conducting quality assurance inspections of transportation packaging and dry spent fuel storage system suppliers. (Suppliers are defined as designers, fabricators, distributors, users or owners of those packaging and storage systems.) This guide may be used during inspection to determine regulatory compliance with 10 CFR, Part 71, Subpart H; 10 CFR, Part 72, Subpart G; 10 CFR, Part 21; and supplier`s quality assurance program commitments. It was developed to provide a structured, consistent approach to inspections. The guidance therein provides a framework for evaluation of transportation packaging and dry spent fuel storage systems quality assurance programs. Inspectors are provided with the flexibility to adapt the methods and concepts to meet inspection requirements for the particular facility. The method used in the guide treats each activity at a facility as a separate performance element and combines the activities within the framework of an ``inspection tree.``The method separates each performance element into several areas for inspection and identifies guidelines, based on regulatory requirements, to qualitatively evaluate each area. This guide also serves as a field manual to facilitate quality assurance inspection activities. This guide replaces an earlier one, NUREG/CR-5717 (Packing Supplier Inspection Guide). This replacement guide enhances the inspection activities for transportation packagings and adds the dry spent fuel storage system quality assurance inspection activities.

  17. Quality assurance inspections for shipping and storage containers

    International Nuclear Information System (INIS)

    Stromberg, H.M.; Roberts, G.D.; Bryce, J.H.

    1996-04-01

    This is a guide for conducting quality assurance inspections of transportation packaging and dry spent fuel storage system suppliers. (Suppliers are defined as designers, fabricators, distributors, users or owners of those packaging and storage systems.) This guide may be used during inspection to determine regulatory compliance with 10 CFR, Part 71, Subpart H; 10 CFR, Part 72, Subpart G; 10 CFR, Part 21; and supplier's quality assurance program commitments. It was developed to provide a structured, consistent approach to inspections. The guidance therein provides a framework for evaluation of transportation packaging and dry spent fuel storage systems quality assurance programs. Inspectors are provided with the flexibility to adapt the methods and concepts to meet inspection requirements for the particular facility. The method used in the guide treats each activity at a facility as a separate performance element and combines the activities within the framework of an ''inspection tree.''The method separates each performance element into several areas for inspection and identifies guidelines, based on regulatory requirements, to qualitatively evaluate each area. This guide also serves as a field manual to facilitate quality assurance inspection activities. This guide replaces an earlier one, NUREG/CR-5717 (Packing Supplier Inspection Guide). This replacement guide enhances the inspection activities for transportation packagings and adds the dry spent fuel storage system quality assurance inspection activities

  18. New Method to Identify Field Joint Coating Failures Based on MFL In-Line Inspection Signals

    Directory of Open Access Journals (Sweden)

    Lianshuang Dai

    2018-02-01

    Full Text Available Above ground indirect detections and random excavations that have applied the past years for buried long distance oil and gas pipelines can only identify some damaged coating locations. Hence, large number of field joint coating (FJC failures happen unconsciously until they lead to failures of the pipelines. Based on the analysis of magnetic flux leakage (MFL in-line inspection (ILI signals, combined with the statistical results of 414 excavations from two different pipeline sections, a new method to identify the failed FJC is established. Though it can only identify FJC failures when there are signs of corrosion on pipe body, it is much more efficient and cost-saving. The concluded identification rule still needs more validations and improvements to be more applicable and accuracy.

  19. Diagnosis of porcine enzootic pneumonia by post mortem sanitary inspection: comparison with other diagnostic methods

    OpenAIRE

    Kênia de Fátima Carrijo; Elmiro Rosendo do Nascimento; Virginia Léo de Almeida Pereira; Nelson Morés; Catia Silene Klein; Leonardo Muliterno Domingues; Rogerio Tortelly

    2014-01-01

    ABSTRACT. Carrijo K.F., Nascimento E.R., Pereira V.L.A., Morés N., Klein, C.S., Domingues L.M. & Tortelly R. [Diagnosis of porcine enzootic pneumonia by post mortem sanitary inspection: comparison with other diagnostic methods.] Diagnóstico da pneumonia enzoótica suína pela inspeção sanitária post mortem: comparação com outros métodos de diagnóstico. Revista Brasileira de Veterinária Brasileira 36(2):188-194, 2014. Faculdade de Medicina Veterinária, Universidade Federal de Uberlândia, Av. Par...

  20. Fundamental study of microelectronic chip response under laser ultrasonic-interferometric inspection using C-scan method

    Science.gov (United States)

    Yang, Lei; Gong, Jie; Ume, I. Charles

    2014-02-01

    In modern surface mount packaging technologies, such as flip chips, chip scale packages, and ball grid arrays(BGA), chips are attached to the substrates/printed wiring board (PWB) using solder bump interconnections. The quality of solder bumps between the chips and the substrate/board is difficult to inspect. Laser ultrasonic-interferometric technique was proved to be a promising approach for solder bump inspection because of its noncontact and nondestructive characteristics. Different indicators extracted from received signals have been used to predict the potential defects, such as correlation coefficient, error ratio, frequency shifting, etc. However, the fundamental understanding of the chip behavior under laser ultrasonic inspection is still missing. Specifically, it is not sure whether the laser interferometer detected out-of-plane displacements were due to wave propagation or structural vibration when the chip was excited by pulsed laser. Plus, it is found that the received signals are chip dependent. Both challenges impede the interpretation of acquired signals. In this paper, a C-scan method was proposed to study the underlying phenomenon during laser ultrasonic inspection. The full chip was inspected. The response of the chip under laser excitation was visualized in a movie resulted from acquired signals. Specifically, a BGA chip was investigated to demonstrate the effectiveness of this method. By characterizing signals using discrete wavelet transform(DWT), both ultrasonic wave propagation and vibration were observed. Separation of them was successfully achieved using ideal band-pass filter and visualized in resultant movies, too. The observed ultrasonic waves were characterized and their respective speeds were measured by applying 2-D FFT. The C-scan method, combined with different digital signal processing techniques, was proved to be an very effective methodology to learn the behavior of chips under laser excitation. This general procedure can be

  1. Investigation of reliability of EC method for inspection of VVER steam generator tubes

    International Nuclear Information System (INIS)

    Corak, Z.

    2004-01-01

    Complete and accurate non-destructive examinations (NDE) data provides the basis for performing mitigating actions and corrective repairs. It is important that detection and characterization of flaws are done properly at an early stage. EPRI Document PWR Steam Generator Examination Guidelines recommends an approach that is intended to provide the following: Ensure accurate assessment of steam generator tube integrity; Extend the reliable, cost effective, operating life of the steam generators, and Maximize the availability of the unit. Steam Generator Eddy Current Data Analysis Performance Demonstration represents the culmination of the intense two-year industry effort in the development of a performance demonstration program for eddy current testing (ECT) of steam generator tubing. It is referred to as the Industry Database (IDB) and provides a capability for individual organizations to implement SG ECT performance demonstration programs in accordance with the requirements specified in Appendices G and H of the ISI Guidelines. The Appendix G of EPRI Document PWR Steam Generator Examination Guidelines specifies personnel training and qualification requirements for NDE personnel who analyze NDE data for PWR steam generator tubing. Its purpose is to insure a continuing uniform knowledge base and skill level for data analysis. The European methodology document is intended to provide a general framework for development of qualifications for the inspection of specific components to ensure they are developed in a consistent way throughout Europe while still allowing qualification to be tailored in detail to meet different nation requirements. In the European methodology document one will not find a detailed description of how the inspection of a specific component should be qualified. A recommended practice is a document produced by ENIQ to support the production of detailed qualification procedures by individual countries. VVER SG tubes are inspected by EC method but a

  2. ROBOTIC TANK INSPECTION END EFFECTOR

    International Nuclear Information System (INIS)

    Rachel Landry

    1999-01-01

    The objective of this contract between Oceaneering Space Systems (OSS) and the Department of Energy (DOE) was to provide a tool for the DOE to inspect the inside tank walls of underground radioactive waste storage tanks in their tank farms. Some of these tanks are suspected to have leaks, but the harsh nature of the environment within the tanks precludes human inspection of tank walls. As a result of these conditions only a few inspection methods can fulfill this task. Of the methods available, OSS chose to pursue Alternating Current Field Measurement (ACFM), because it does not require clean surfaces for inspection, nor any contact with the Surface being inspected, and introduces no extra by-products in the inspection process (no coupling fluids or residues are left behind). The tool produced by OSS is the Robotic Tank Inspection End Effector (RTIEE), which is initially deployed on the tip of the Light Duty Utility Arm (LDUA). The RTEE combines ACFM with a color video camera for both electromagnetic and visual inspection The complete package consists of an end effector, its corresponding electronics and software, and a user's manual to guide the operator through an inspection. The system has both coarse and fine inspection modes and allows the user to catalog defects and suspected areas of leakage in a database for further examination, which may lead to emptying the tank for repair, decommissioning, etc.. The following is an updated report to OSS document OSS-21100-7002, which was submitted in 1995. During the course of the contract, two related sub-tasks arose, the Wall and Coating Thickness Sensor and the Vacuum Scarifying and Sampling Tool Assembly. The first of these sub-tasks was intended to evaluate the corrosion and wall thinning of 55-gallon steel drums. The second was retrieved and characterized the waste material trapped inside the annulus region of the underground tanks on the DOE's tank farms. While these sub-tasks were derived from the original intent

  3. The analysis of the accuracy of the wheel alignment inspection method on the side-slip plate stand

    Science.gov (United States)

    Gajek, A.; Strzępek, P.

    2016-09-01

    The article presents the theoretical basis and the results of the examination of the wheel alignment inspection method on the slide slip plate stand. It is obligatory test during periodic technical inspection of the vehicle. The measurement is executed in the dynamic conditions. The dependence between the lateral displacement of the plate and toe-in of the tested wheels has been shown. If the diameter of the wheel rim is known then the value of the toe-in can be calculated. The comparison of the toe-in measurements on the plate stand and on the four heads device for the wheel alignment inspection has been carried out. The accuracy of the measurements and the influence of the conditions of the tests on the plate stand (the way of passing through the plate) were estimated. The conclusions about the accuracy of this method are presented.

  4. Analysis of risk of nonconformities and applied quality inspection methods in the process of aluminium profiles coating based on FMEA results

    OpenAIRE

    Krzysztof Knop

    2017-01-01

    The article presents the results of risk analysis associated with nonconformities of aluminium profiles in the process of coating and quality inspection methods used to their detection. Analysis of risk was done based on results of FMEA method. Evaluated quality inspection methods were distinguished based on the term of inspection in the ISO 9000:2005 norm. Manufacturing process of aluminium profile in micro-technological approach was presented. Triple quantification of nonconformities risk b...

  5. A Vision-Based Self-Calibration Method for Robotic Visual Inspection Systems

    Science.gov (United States)

    Yin, Shibin; Ren, Yongjie; Zhu, Jigui; Yang, Shourui; Ye, Shenghua

    2013-01-01

    A vision-based robot self-calibration method is proposed in this paper to evaluate the kinematic parameter errors of a robot using a visual sensor mounted on its end-effector. This approach could be performed in the industrial field without external, expensive apparatus or an elaborate setup. A robot Tool Center Point (TCP) is defined in the structural model of a line-structured laser sensor, and aligned to a reference point fixed in the robot workspace. A mathematical model is established to formulate the misalignment errors with kinematic parameter errors and TCP position errors. Based on the fixed point constraints, the kinematic parameter errors and TCP position errors are identified with an iterative algorithm. Compared to the conventional methods, this proposed method eliminates the need for a robot-based-frame and hand-to-eye calibrations, shortens the error propagation chain, and makes the calibration process more accurate and convenient. A validation experiment is performed on an ABB IRB2400 robot. An optimal configuration on the number and distribution of fixed points in the robot workspace is obtained based on the experimental results. Comparative experiments reveal that there is a significant improvement of the measuring accuracy of the robotic visual inspection system. PMID:24300597

  6. In-service inspection of nuclear power plants

    International Nuclear Information System (INIS)

    1991-01-01

    This Manual is intended to provide more comprehensive considerations on the management, organization, preparation, improvement and implementation of in-service inspection activities and the related surveillance. It also gives illustrative examples of good practices and recommendations from operating and other organizations that are consistent with the requirements and recommendations of the Code and Safety Guides. The Manual is directed primarily towards plant management. This Manual should be used in conjunction with the Code and the Safety Guides, in particular with IAEA Safety Series Nos. 50-C-O, 50-SG-O2, 50-SG-05, 50-SG-07, 50-SG-08 and 50-SG-D1, which contain recommendations of a general character about maintenance activities and radiation protection in an operating power plant, and with the 'Manual on the Maintenance of Systems and Components Important to Safety'. This Manual is divided into four technical sections. The first introduces the purpose, structure and main requirements of the programme. The second section describes constituents of the programme, recommending its scope, scheduling, acceptance standards and documentation of results. The following section goes into details of the inspection programme's contents, such as the selection of components, inspection locations, defect types, applicable techniques and procedures, and the evaluation of results. The last section specifies recommended methods and techniques for inspection, such as visual, ultrasonic, eddy current, magnetic particle and others. This main part of the Manual is complemented by a number of annexes which reproduce actual national examples of established procedures, ISI programme parts, acceptance standards, personnel training programmes, testing techniques and other aspects of in-service inspection, illustrating practical implementation of the recommendations of the Manual

  7. Massage, reflexology and other manual methods for pain management in labour.

    Science.gov (United States)

    Smith, Caroline A; Levett, Kate M; Collins, Carmel T; Dahlen, Hannah G; Ee, Carolyn C; Suganuma, Machiko

    2018-03-28

    Many women would like to avoid pharmacological or invasive methods of pain management in labour, and this may contribute towards the popularity of complementary methods of pain management. This review examined the evidence currently available on manual methods, including massage and reflexology, for pain management in labour. This review is an update of the review first published in 2012. To assess the effect, safety and acceptability of massage, reflexology and other manual methods to manage pain in labour. For this update, we searched Cochrane Pregnancy and Childbirth's Trials Register (30 June 2017), the Cochrane Central Register of Controlled Trials (CENTRAL; 2017, Issue 6), MEDLINE (1966 to 30 June 2017, CINAHL (1980 to 30 June 2017), the Australian New Zealand Clinical Trials Registry (4 August 2017), Chinese Clinical Trial Registry (4 August 2017), ClinicalTrials.gov, (4 August 2017), the National Center for Complementary and Integrative Health (4 August 2017), the WHO International Clinical Trials Registry Platform (ICTRP) (4 August 2017) and reference lists of retrieved trials. We included randomised controlled trials comparing manual methods with standard care, other non-pharmacological forms of pain management in labour, no treatment or placebo. We searched for trials of the following modalities: massage, warm packs, thermal manual methods, reflexology, chiropractic, osteopathy, musculo-skeletal manipulation, deep tissue massage, neuro-muscular therapy, shiatsu, tuina, trigger point therapy, myotherapy and zero balancing. We excluded trials for pain management relating to hypnosis, aromatherapy, acupuncture and acupressure; these are included in other Cochrane reviews. Two review authors independently assessed trial quality, extracted data and checked data for accuracy. We contacted trial authors for additional information. We assessed the quality of the evidence using the GRADE approach. We included a total of 14 trials; 10 of these (1055 women

  8. Comparison of manual and automated pretreatment methods for AMS radiocarbon dating of plant fossils

    Science.gov (United States)

    Bradley, L.A.; Stafford, Thomas W.

    1994-01-01

    A new automated pretreatment system for the preparation of materials submitted for accelerator mass spectrometry (AMS) analysis is less time-consuming and results in a higher sample yield. The new procedure was tested using two groups of plant fossils: one group was pretreated using the traditional method, and the second, using the automated pretreatment apparatus. The time it took to complete the procedure and the amount of sample material remaining were compared. The automated pretreatment apparatus proved to be more than three times faster and, in most cases, produced a higher yield. A darker discoloration of the KOH solutions was observed indicating that the automated system is more thorough in removing humates from the specimen compared to the manual method. -Authors

  9. Automated PCB Inspection System

    Directory of Open Access Journals (Sweden)

    Syed Usama BUKHARI

    2017-05-01

    Full Text Available Development of an automated PCB inspection system as per the need of industry is a challenging task. In this paper a case study is presented, to exhibit, a proposed system for an immigration process of a manual PCB inspection system to an automated PCB inspection system, with a minimal intervention on the existing production flow, for a leading automotive manufacturing company. A detailed design of the system, based on computer vision followed by testing and analysis was proposed, in order to aid the manufacturer in the process of automation.

  10. Larvas output and influence of human factor in reliability of meat inspection by the method of artificial digestion

    Directory of Open Access Journals (Sweden)

    Đorđević Vesna

    2013-01-01

    Full Text Available On the basis of the performed analyses of the factors that contributed the infected meat reach food chain, we have found out that the infection occurred after consuming the meat inspected by the method of collective samples artificial digestion by using a magnetic stirrer (MM. In this work there are presented assay results which show how modifications of the method, on the level of final sedimentation, influence the reliability of Trichinella larvas detection in the infected meat samples. It has been shown that use of inadequate laboratory containers for larva collecting in final sedimentation and change of volume of digestive liquid that outflow during colouring preparations, can significantly influence inspection results. Larva detection errors ranged from 4 to 80% in presented the experimental groups in regard to the control group of samples inspected by using MM method, which had been carried out completely according to Europe Commission procedure No 2075/2005, where no errors in larva number per sample was found. We consider that the results of this work will contribute to the improvement of control of the method performance and especially of the critical point during inspection of meat samples to Trichinella larvas in Serbia.

  11. Methane measurements manual; Handbok metanmaetningar

    Energy Technology Data Exchange (ETDEWEB)

    Holmgren, Magnus Andreas (SP Technical research institute of Sweden, Boraas (Sweden))

    2011-02-15

    Emissions to air in different parts of the system may arise in biogas plants, where there is biological treatment of organic matter by anaerobic degradation, and during upgrading of biogas to vehicle fuel. There are mainly four reasons why these emissions must be minimized. These are safety, greenhouse gas emissions, economy and smell. This manual gathers experience of several years of work with measurement of methane emissions from biogas and upgrading facilities. This work has been done mainly in the context of Swedish Waste Management's system of voluntary commitment. The purpose of this manual is to standardize methods and procedures when methane measurements are carried out so that the results are comparable between different providers. The main target group of the manual is measurement consultants performing such measurements. Calculation template in Excel is part of the manual, which further contributes to the measurements evaluated in a standardized way. The manual contains several examples which have been calculated in the accompanying Excel template. The handbook also contains a chapter mainly intended for facility staff, in which implementation of accurate leak detection is described, and where there are hints of a system of so-called intermediate inspections to detect leaks in time

  12. MATADOR (Methods for the Analysis of Transport And Deposition Of Radionuclides) code description and User's Manual

    International Nuclear Information System (INIS)

    Avci, H.I.; Raghuram, S.; Baybutt, P.

    1985-04-01

    A new computer code called MATADOR (Methods for the Analysis of Transport And Deposition Of Radionuclides) has been developed to replace the CORRAL-2 computer code which was written for the Reactor Safety Study (WASH-1400). This report is a User's Manual for MATADOR. MATADOR is intended for use in system risk studies to analyze radionuclide transport and deposition in reactor containments. The principal output of the code is information on the timing and magnitude of radionuclide releases to the environment as a result of severely degraded core accidents. MATADOR considers the transport of radionuclides through the containment and their removal by natural deposition and by engineered safety systems such as sprays. It is capable of analyzing the behavior of radionuclides existing either as vapors or aerosols in the containment. The code requires input data on the source terms into the containment, the geometry of the containment, and thermal-hydraulic conditions in the containment

  13. Defect inspection in hot slab surface: multi-source CCD imaging based fuzzy-rough sets method

    Science.gov (United States)

    Zhao, Liming; Zhang, Yi; Xu, Xiaodong; Xiao, Hong; Huang, Chao

    2016-09-01

    To provide an accurate surface defects inspection method and make the automation of robust image region of interests(ROI) delineation strategy a reality in production line, a multi-source CCD imaging based fuzzy-rough sets method is proposed for hot slab surface quality assessment. The applicability of the presented method and the devised system are mainly tied to the surface quality inspection for strip, billet and slab surface etcetera. In this work we take into account the complementary advantages in two common machine vision (MV) systems(line array CCD traditional scanning imaging (LS-imaging) and area array CCD laser three-dimensional (3D) scanning imaging (AL-imaging)), and through establishing the model of fuzzy-rough sets in the detection system the seeds for relative fuzzy connectedness(RFC) delineation for ROI can placed adaptively, which introduces the upper and lower approximation sets for RIO definition, and by which the boundary region can be delineated by RFC region competitive classification mechanism. For the first time, a Multi-source CCD imaging based fuzzy-rough sets strategy is attempted for CC-slab surface defects inspection that allows an automatic way of AI algorithms and powerful ROI delineation strategies to be applied to the MV inspection field.

  14. Kartini reactor tank inspection using NDT method for safety improvement of the reactor operation

    International Nuclear Information System (INIS)

    Syarip; Sutondo, Tegas; Saleh, Chaerul; Nitiswati; Puradwi; Andryansah; Mudiharjo

    2002-01-01

    The inspection of Kartini reactor tank liner (TRK) by using Non Destructive Testing (NDT) methods to improve the reactor operation safety, have been done. The type of NDT used were: visual examination using an underwater camera and magnifier, replication survey using dental putty, hardness test using an Equotip D indentor, thickness test using ultrasonic probe, and dye penetrant test. The visual examination showed that the surface of TRK was in good condition. The hardness readings were considered to be consistent with the original condition of the tank and the slight hardness increase at the reactor core area consistent with the neutron fluence experienced -10 1 4 n/cm 2 . Results of ultrasonic thickness survey showed that in average the TRK thickness is between 5,0 mm - 6,5 mm, a low 2,1 mm thickness exists at the top of the TRK in the belt area (double layer aluminum plat, therefore do not influencing the safety ). The replica and dye penetrant test at the low thickness area and several suspected areas showed that it could be some defect from original manufacture. Therefore, it can be concluded that the TRK is still feasible for continued operation safely

  15. Advanced cutting, welding and inspection methods for vacuum vessel assembly and maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Jones, L. E-mail: jonesl@ipp.mgg.de; Alfile, J.-P.; Aubert, Ph.; Punshon, C.; Daenner, W.; Kujanpaeae, V.; Maisonnier, D.; Serre, M.; Schreck, G.; Wykes, M

    2000-11-01

    ITER requires a 316 l stainless steel, double-skinned vacuum vessel (VV), each shell being 60 mm thick. EFDA (European Fusion Development Agreement) is investigating methods to be used for performing welding and NDT during VV assembly and also cutting and re-welding for remote sector replacement, including the development of an Intersector Welding Robot (IWR) [Jones et al. This conference]. To reduce the welding time, distortions and residual stresses of conventional welding, previous work concentrated on CO{sub 2} laser welding and cutting processes [Jones et al. Proc. Symp. Fusion Technol., Marseilles, 1998]. NdYAG laser now provides the focus for welding of the rearside root and for completing the weld for overhead positions with multipass filling. Electron beam (E-beam) welding with local vacuum offers a single-pass for most of the weld depth except for overhead positions. Plasma cutting has shown the capability to contain the backside dross and preliminary work with NdYAG laser cutting has shown good results. Automated ultrasonic inspection of assembly welds will be improved by the use of a phased array probe system that can focus the beam for accurate flaw location and sizing. This paper describes the recent results of process investigations in this R and D programme, involving five European sites and forming part of the overall VV/blanket research effort [W. Daenner et al. This conference].

  16. A PCA and ELM Based Adaptive Method for Channel Equalization in MFL Inspection

    Directory of Open Access Journals (Sweden)

    Zhenning Wu

    2014-01-01

    Full Text Available Magnetic flux leakage (MFL as an efficient method for pipeline flaw detection plays important role in pipeline safety. This nondestructive test technique assesses the health of the buried pipeline. The signal is gathered by an array of hall-effect sensors disposed at the magnetic neutral plane of a pair of permanent magnet in the pipeline inspection gauge (PIG clinging to the inner surface of the pipe wall. The magnetic flux measured by the sensors reflects the health condition of the pipe. The signal is influenced by not only the condition of the pipe, but also by the lift-off value of the sensors and various properties of electronic component. The consistency of the position of the sensors is almost never satisfied and each sensor measures differently. In this paper, a new scheme of channel equalization is proposed for MFL signal in order to correct sensor misalignments, which eventually improves accuracy of defect characterization. The algorithm proposed in this paper is adaptive to the effects of error on the disposition of the sensor due to manufacturing imperfections and movements of the sensors. The algorithm is tested by data acquired from an experimental pipeline. The results show the effectiveness of the proposed algorithm.

  17. Tooth-size discrepancy: A comparison between manual and digital methods

    Directory of Open Access Journals (Sweden)

    Gabriele Dória Cabral Correia

    2014-08-01

    Full Text Available INTRODUCTION: Technological advances in Dentistry have emerged primarily in the area of diagnostic tools. One example is the 3D scanner, which can transform plaster models into three-dimensional digital models. OBJECTIVE: This study aimed to assess the reliability of tooth size-arch length discrepancy analysis measurements performed on three-dimensional digital models, and compare these measurements with those obtained from plaster models. MATERIAL AND METHODS: To this end, plaster models of lower dental arches and their corresponding three-dimensional digital models acquired with a 3Shape R700T scanner were used. All of them had lower permanent dentition. Four different tooth size-arch length discrepancy calculations were performed on each model, two of which by manual methods using calipers and brass wire, and two by digital methods using linear measurements and parabolas. RESULTS: Data were statistically assessed using Friedman test and no statistically significant differences were found between the two methods (P > 0.05, except for values found by the linear digital method which revealed a slight, non-significant statistical difference. CONCLUSIONS: Based on the results, it is reasonable to assert that any of these resources used by orthodontists to clinically assess tooth size-arch length discrepancy can be considered reliable.

  18. A novel method for the quantification of key components of manual dexterity after stroke

    OpenAIRE

    T?r?metz, Maxime; Colle, Florence; Hamdoun, Sonia; Maier, Marc A.; Lindberg, P?vel G.

    2015-01-01

    Background A high degree of manual dexterity is a central feature of the human upper limb. A rich interplay of sensory and motor components in the hand and fingers allows for independent control of fingers in terms of timing, kinematics and force. Stroke often leads to impaired hand function and decreased manual dexterity, limiting activities of daily living and impacting quality of life. Clinically, there is a lack of quantitative multi-dimensional measures of manual dexterity. We therefore ...

  19. Development of an ultrasonic nondestructive inspection method for impact damage detection in composite aircraft structures

    Science.gov (United States)

    Capriotti, M.; Kim, H. E.; Lanza di Scalea, F.; Kim, H.

    2017-04-01

    High Energy Wide Area Blunt Impact (HEWABI) due to ground service equipment can often occur in aircraft structures causing major damages. These Wide Area Impact Damages (WAID) can affect the internal components of the structure, hence are usually not visible nor detectable by typical one-sided NDE techniques and can easily compromise the structural safety of the aircraft. In this study, the development of an NDI method is presented together with its application to impacted aircraft frames. The HEWABI from a typical ground service scenario has been previously tested and the desired type of damages have been generated, so that the aircraft panels could become representative study cases. The need of the aircraft industry for a rapid, ramp-friendly system to detect such WAID is here approached with guided ultrasonic waves (GUW) and a scanning tool that accesses the whole structure from the exterior side only. The wide coverage of the specimen provided by GUW has been coupled to a differential detection approach and is aided by an outlier statistical analysis to be able to inspect and detect faults in the challenging composite material and complex structure. The results will be presented and discussed with respect to the detection capability of the system and its response to the different damage types. Receiving Operating Characteristics curves (ROC) are also produced to quantify and assess the performance of the proposed method. Ongoing work is currently aimed at the penetration of the inner components of the structure, such as shear ties and C-frames, exploiting different frequency ranges and signal processing techniques. From the hardware and tool development side, different transducers and coupling methods, such as air-coupled transducers, are under investigation together with the design of a more suitable scanning technique.

  20. Characterization of hazardous waste sites: a methods manual. Volume 2. Available sampling methods (second edition)

    International Nuclear Information System (INIS)

    Ford, P.J.; Turina, P.J.; Seely, D.E.

    1984-12-01

    Investigations at hazardous waste sites and sites of chemical spills often require on-site measurements and sampling activities to assess the type and extent of contamination. This document is a compilation of sampling methods and materials suitable to address most needs that arise during routine waste site and hazardous spill investigations. The sampling methods presented in this document are compiled by media, and were selected on the basis of practicality, economics, representativeness, compatability with analytical considerations, and safety, as well as other criteria. In addition to sampling procedures, sample handling and shipping, chain-of-custody procedures, instrument certification, equipment fabrication, and equipment decontamination procedures are described. Sampling methods for soil, sludges, sediments, and bulk materials cover the solids medium. Ten methods are detailed for surface waters, groundwater and containerized liquids; twelve are presented for ambient air, soil gases and vapors, and headspace gases. A brief discussion of ionizing radiation survey instruments is also provided

  1. Validation of hippocampal volumes measured using a manual method and two automated methods (FreeSurfer and IBASPM) in chronic major depressive disorder

    Energy Technology Data Exchange (ETDEWEB)

    Tae, Woo Suk; Lee, Kang Uk; Nam, Eui-Cheol; Kim, Keun Woo [Kangwon National University College of Medicine, Neuroscience Research Institute, Kangwon (Korea); Kim, Sam Soo [Kangwon National University College of Medicine, Neuroscience Research Institute, Kangwon (Korea); Kangwon National University Hospital, Department of Radiology, Kangwon-do (Korea)

    2008-07-15

    To validate the usefulness of the packages available for automated hippocampal volumetry, we measured hippocampal volumes using one manual and two recently developed automated volumetric methods. The study included T1-weighted magnetic resonance imaging (MRI) of 21 patients with chronic major depressive disorder (MDD) and 20 normal controls. Using coronal turbo field echo (TFE) MRI with a slice thickness of 1.3 mm, the hippocampal volumes were measured using three methods: manual volumetry, surface-based parcellation using FreeSurfer, and individual atlas-based volumetry using IBASPM. In addition, the intracranial cavity volume (ICV) was measured manually. The absolute left hippocampal volume of the patients with MDD measured using all three methods was significantly smaller than the left hippocampal volume of the normal controls (manual P=0.029, FreeSurfer P=0.035, IBASPM P=0.018). After controlling for the ICV, except for the right hippocampal volume measured using FreeSurfer, both measured hippocampal volumes of the patients with MDD were significantly smaller than the measured hippocampal volumes of the normal controls (right manual P=0.019, IBASPM P=0.012; left manual P=0.003, FreeSurfer P=0.010, IBASPM P=0.002). In the intrarater reliability test, the intraclass correlation coefficients (ICCs) were all excellent (manual right 0.947, left 0.934; FreeSurfer right 1.000, left 1.000; IBASPM right 1.000, left 1.000). In the test of agreement between the volumetric methods, the ICCs were right 0.846 and left 0.848 (manual and FreeSurfer), and right 0.654 and left 0.717 (manual and IBASPM). The automated hippocampal volumetric methods showed good agreement with manual hippocampal volumetry, but the volume measured using FreeSurfer was 35% larger and the agreement was questionable with IBASPM. Although the automated methods could detect hippocampal atrophy in the patients with MDD, the results indicate that manual hippocampal volumetry is still the gold standard

  2. Validation of hippocampal volumes measured using a manual method and two automated methods (FreeSurfer and IBASPM) in chronic major depressive disorder

    International Nuclear Information System (INIS)

    Tae, Woo Suk; Lee, Kang Uk; Nam, Eui-Cheol; Kim, Keun Woo; Kim, Sam Soo

    2008-01-01

    To validate the usefulness of the packages available for automated hippocampal volumetry, we measured hippocampal volumes using one manual and two recently developed automated volumetric methods. The study included T1-weighted magnetic resonance imaging (MRI) of 21 patients with chronic major depressive disorder (MDD) and 20 normal controls. Using coronal turbo field echo (TFE) MRI with a slice thickness of 1.3 mm, the hippocampal volumes were measured using three methods: manual volumetry, surface-based parcellation using FreeSurfer, and individual atlas-based volumetry using IBASPM. In addition, the intracranial cavity volume (ICV) was measured manually. The absolute left hippocampal volume of the patients with MDD measured using all three methods was significantly smaller than the left hippocampal volume of the normal controls (manual P=0.029, FreeSurfer P=0.035, IBASPM P=0.018). After controlling for the ICV, except for the right hippocampal volume measured using FreeSurfer, both measured hippocampal volumes of the patients with MDD were significantly smaller than the measured hippocampal volumes of the normal controls (right manual P=0.019, IBASPM P=0.012; left manual P=0.003, FreeSurfer P=0.010, IBASPM P=0.002). In the intrarater reliability test, the intraclass correlation coefficients (ICCs) were all excellent (manual right 0.947, left 0.934; FreeSurfer right 1.000, left 1.000; IBASPM right 1.000, left 1.000). In the test of agreement between the volumetric methods, the ICCs were right 0.846 and left 0.848 (manual and FreeSurfer), and right 0.654 and left 0.717 (manual and IBASPM). The automated hippocampal volumetric methods showed good agreement with manual hippocampal volumetry, but the volume measured using FreeSurfer was 35% larger and the agreement was questionable with IBASPM. Although the automated methods could detect hippocampal atrophy in the patients with MDD, the results indicate that manual hippocampal volumetry is still the gold standard

  3. Analysis of risk of nonconformities and applied quality inspection methods in the process of aluminium profiles coating based on FMEA results

    Directory of Open Access Journals (Sweden)

    Krzysztof Knop

    2017-10-01

    Full Text Available The article presents the results of risk analysis associated with nonconformities of aluminium profiles in the process of coating and quality inspection methods used to their detection. Analysis of risk was done based on results of FMEA method. Evaluated quality inspection methods were distinguished based on the term of inspection in the ISO 9000:2005 norm. Manufacturing process of aluminium profile in micro-technological approach was presented. Triple quantification of nonconformities risk based on the FMEA method by using three different approaches was conducted. Analysis of nonconformities risks associated with the use of specific quality inspection methods was done. In the last part the analysis of causes of critical nonconformities, proposals for improvement actions reducing the risk of the critical nonconformities and applied critical quality inspection method were showed.

  4. Inspection method of cable-stayed bridge using magnetic flux leakage detection: principle, sensor design, and signal processing

    International Nuclear Information System (INIS)

    Xu, Fengyu; Wang, Xingsong; Wu, Hongtao

    2012-01-01

    A nondestructive testing technique based on magnetic flux leakage is presented to inspect automatically the stay cables with large diameters of a cable-stayed bridge. Using the proposed inspection method, an online nondestructive testing (NDT) modular sensor is developed. The wreath-like sensor is composed of several sensor units that embrace the cable at equal angles. Each sensor unit consists of two permanent magnets and a hall sensor to detect the magnetic flux density. The modular sensor can be installed conveniently on cables with various diameters by increasing the number of sensor units and adjusting the relative distances between adjacent sensor units. Results of the experiments performed on a man-made cable with faults prove that the proposed sensor can inspect the status signals of the inner wires of the cables. To filter the interfering signals, three processing algorithms are discussed, including the moving average method, improved detrending algorithm, and signal processing based on a digital filter. Results show that the developed NDT sensor carried by a cable inspection robot can move along the cable and monitor the state of the stay cables

  5. Are the new automated methods for bone age estimation advantageous over the manual approaches?

    Science.gov (United States)

    De Sanctis, Vincenzo; Soliman, Ashraf T; Di Maio, Salvatore; Bedair, Said

    2014-12-01

    Bone Age Assessment (BAA) is performed worldwide for the evaluation of endocrine, genetic and chronic diseases, to monitor response to medical therapy and to determine the growth potential of children and adolescents. It is also used for consultation in planning orthopedic procedures, for determination of chronological age for adopted children, youth sports participation and in forensic settings. The main clinical methods for skeletal bone age estimation are the Greulich and Pyle (GP) and the Tanner and Whitehouse (TW) methods. Seventy six per cent (76%) of radiologists or pediatricians usually use the method of GP, 20% that of TW and 4% other methods. The advantages of using the TW method, as opposed to the GP method, are that it overcomes the subjectivity problem and results are more reproducible. However, it is complex and time consuming; for this reason its usage is just about 20% on a world-wide scale. Moreover, there are some evidences that bone age assignments by different physicians can differ significantly. Computerized and Quantitative Ultrasound Technologies (QUS) for assessing skeletal maturity have been developed with the aim of reducing many of the inconsistencies associated with radiographic investigations. In spite of the fact that the volume of automated methods for BAA has increased, the majotity of them are still in an early phase of development. QUS is comparable to the GP based method, but there is not enough established data yet for the healthy population. The Authors wish to stimulate the attention on the accuracy, reliability and consistency of BAA and to initiate a debate on manual versus automated approaches to enhance our assessment for skeletal matutation in children and adolescents.

  6. Characterization of mixed waste for sorting and inspection using non-intrusive methods

    International Nuclear Information System (INIS)

    Roberson, G.P.; Ryon, R.W.; Bull, N.L.

    1994-12-01

    Characterization of mixed wastes (that is, radioactive and otherwise hazardous) requires that all hazardous, non-conforming, and radioactive materials be identified, localized, and quantified. With such information, decisions can be made regarding whether the item is treatable or has been adequately treated. Much of the required information can be gained without taking representative samples and analyzing them in a chemistry laboratory. Non-intrusive methods can be used to provide this information on-line at the waste treatment facility. Ideally, the characterization would be done robotically, and either automatically or semi-automatically in order to improve efficiency and safety. For the FY94 Mixed Waste Operations (MWO) project, a treatable waste item is defined as a homogeneous metal object that has external radioactive or heavy metal hazardous contamination. Surface treatment of some kind would therefore be the treatment method to be investigated. The authors developed sorting and inspection requirements, and assessed viable non-intrusive techniques to meet these requirements. They selected radiography, computed tomography and X-ray fluorescence. They have characterized selected mock waste items, and determined minimum detectable amounts of materials. They have demonstrated the efficiency possible by integrating radiographic with tomographic data. Here, they developed a technique to only use radiographic data where the material is homogeneous (fast), and then switching to tomography in those areas where heterogeneity is detected (slower). They also developed a tomographic technique to quantify the volume of each component of a mixed material. This is useful for such things as determining ash content. Lastly, they have developed a document in MOSAIC, an Internet multi-media browser. This document is used to demonstrate the ability to share data and information world-wide

  7. Nuclear fuel assembly grid sleeve/guide thimble bulge orientation gage and inspection method

    International Nuclear Information System (INIS)

    Widener, W.H.

    1988-01-01

    This patent describes a method of inspecting a fuel assembly to determine the orientation of externally-projecting mated bulges connecting a grid sleeve to a guide thimble of the assembly, the method comprising the steps of: (a) inserting a radially-expandable tubular member within the guide thimble, the tubular member having externally-projecting embossments thereon spaced circumferentially from one another about the tubular member, the embossments being the same in number as the bulges of the guide thimble and configured to fit therewithin; (b) axially moving an elongated expansion member, which extends through and rotatably mounts the tubular member, relative to the tubular member from a first position in which the expansion member permits inward contraction of the tubular member and displacement of embossments thereon away from the interior of the guide thimble bulges for removing the embossments from registry therewith and a second position in which the expansion member produces radial expansion of the tubular member and displacement of the embossments thereon toward the interior of the guide thimble bulges for placing the embossments in registry therewith; (c) rotating the tubular member relative to the expansion member so as to bring the embossments on the tubular member into alignment with the guide thimble bulges as the embossments on the tubular member are being displaced toward and into registry with the interior of the bulges; and (d) responsive to rotation of the tubular member away from a reference position, providing an indication of the orientation of the guide thimble bulges relative to a reference point upon displacement of the embossments into registry therewith

  8. Larvas output and influence of human factor in reliability of meat inspection by the method of artificial digestion

    OpenAIRE

    Đorđević Vesna; Savić Marko; Vasilev Saša; Đorđević Milovan

    2013-01-01

    On the basis of the performed analyses of the factors that contributed the infected meat reach food chain, we have found out that the infection occurred after consuming the meat inspected by the method of collective samples artificial digestion by using a magnetic stirrer (MM). In this work there are presented assay results which show how modifications of the method, on the level of final sedimentation, influence the reliability of Trichinella larvas detect...

  9. A Method for Automatic Inspection of Printed Circuit Boards by Using the Thermal Signature

    International Nuclear Information System (INIS)

    Amer, H.H.; Zekry, A.A.; Elaraby, S.; Ghareeb, K.E.

    2012-01-01

    This paper aims to design a system for automating inspection of the printed circuit boards (PCBs) by using the thermal signature of the different integrated circuits (I.C). The proposed inspection system consists of the inspection circuit, data acquisition system (DAS) and personal computer. Inspection is done by comparing the thermal signature of normally operated circuit with the thermal signature of circuit under test. One thermistor is assigned to each component in the circuit. The thermistor must touch tightly the surface of the I.C. to sense its temperature during the inspection process. Matlab software is used to represent the thermal signature through different colors. The Turbo C software is used to develop a program for acquiring and comparing the thermal signature of the circuit under the test with the reference circuit. If the colors of the two thermal signatures for the same I.C. are same then the circuit under test is fault free and does not contain any defect. On the other side, if the colors of the two thermal signatures for the same I.C. are different then the circuit under test is defective

  10. Application work risk of manual material handling operators using different lifting methods

    Science.gov (United States)

    Anizar; Matondang, AR; Sibarani, JA

    2018-02-01

    This study observed the activity of lifting and moving crates containing bottles at a pallet station in a carbonated drink factory. The activity of moving crates, each weighing 15 kg, is performed by four operators using different methods. An operator manually moves 250 crates daily and often takes rest during working. This study aims to find the most efficient method, that is using the least energy, to move crates. The workload is assessed using the method of Cardiovascular Strain Load (CVL) and energy expenditure. Operators’ arterial pulse is measured for 1 minute right before they start working and after they finish working; this is done to obtain work arterial pulse and rest arterial pulse. The way operators lift crates is analyzed using biomechanics. It is found that fatigue is experienced by all operators, with the exception of the 3rd operator who has a %CVL number below 30%. He positions the pallet to be parallel to the conveyor, and then stand in between during the lifting process. He only rotates his body to move the crate from the conveyor onto the pallet, requiring only little energy. This is one of the reasons why the %CVL number is lower than the other operators.

  11. [Comparison of manual and automated (MagNA Pure) nucleic acid isolation methods in molecular diagnosis of HIV infections].

    Science.gov (United States)

    Alp, Alpaslan; Us, Dürdal; Hasçelik, Gülşen

    2004-01-01

    Rapid quantitative molecular methods are very important for the diagnosis of human immunodeficiency virus (HIV) infections, assessment of prognosis and follow up. The purpose of this study was to compare and evaluate the performances of conventional manual extraction method and automated MagNA Pure system, for the nucleic acid isolation step which is the first and most important step in molecular diagnosis of HIV infections. Plasma samples of 35 patients in which anti-HIV antibodies were found as positive by microparticule enzyme immunoassay and confirmed by immunoblotting method, were included in the study. The nucleic acids obtained simultaneously by manual isolation kit (Cobas Amplicor, HIV-1 Monitor Test, version 1.5, Roche Diagnostics) and automated system (MagNA Pure LC Total Nucleic Acid Isolation Kit, Roche Diagnostics), were amplified and detected in Cobas Amplicor (Roche Diagnostics) instrument. Twenty three of 35 samples (65.7%) were found to be positive, and 9 (25.7%) were negative by both of the methods. The agreement between the methods were detected as 91.4%, for qualitative results. Viral RNA copies detected by manual and MagNA Pure isolation methods were found between 76.0-7.590.000 (mean: 487.143) and 113.0-20.300.0000 (mean: 2.174.097) copies/ml, respectively. When both of the overall and individual results were evaluated, the number of RNA copies obtained with automatized system, were found higher than the manual method (p<0.05). Three samples which had low numbers of nucleic acids (113, 773, 857, respectively) with MagNA Pure, yielded negative results with manual method. In conclusion, the automatized MagNA Pure system was found to be a reliable, rapid and practical method for the isolation of HIV-RNA.

  12. System and method for online inspection of turbines using an optical tube with broadspectrum mirrors

    Science.gov (United States)

    Baleine, Erwan

    2015-12-22

    An optical inspection system for nondestructive internal visual inspection and non-contact infra-red (IR) temperature monitoring of an online, operating power generation turbine. The optical inspection system includes an optical tube having a viewing port, at least one reflective mirror or a mirror array having a reflectivity spectral range from 550 nm to 20 .mu.m, and capable of continuous operation at temperatures greater than 932 degrees Fahrenheit (500 degrees Celsius), and a transparent window with high transmission within the same spectral range mounted distal the viewing port. The same optical mirror array may be used to measure selectively surface temperature of metal turbine blades in the near IR range (approximately 1 .mu.m wavelength) and of thermal barrier coated turbine blades in the long IR range (approximately 10 .mu.m wavelength).

  13. Proposal of inspection method of radiation protection applied to nuclear medicine establishments

    International Nuclear Information System (INIS)

    Mendes, Leopoldino da Cruz Gouveia

    2003-01-01

    The principal objective of this paper is to implement a method of an impartial and efficient inspection, due to a correct and secure dose of ionizing radiation in the field of Nuclear Medicine. The Radiological Protection Model was tested in 113 Nuclear Medicine Services all over the country, according to a biannual analysis frequency (1996, 1998, 2000 and 2002). The data sheet comprised general information about the structure of the NMS and a technical approach. In the analytical process, a methodology of inputting different importance levels to each of the 82 features was adopted, based on the risk factors stated in the CNEN NE's and in the IAEA recommendations, as well. From this point of view, as a feature does not fit one of the rules above, it will correspond to a radioprotection fault and be imparted a grade. The sum of those grades, classified the NMS in one of the three different ranges, as follows: - operating without restriction - 100 points and below- operating with restriction - between 100 and 300 points - temporary shutdown - above and equal to 300 points. The allowance of the second group to carry on operating should be attached to a defined and restricted period of time (six to twelve months), supposed large enough to the NMS solving the problems being new evaluation proceeded then. The NMS's classified in the third group are supposed to go back into operation only when fit all the pending radioprotection requirements. Until the next regular evaluation, meanwhile a multiplication factor 2 n was applied to the recalcitrant NMS s where n is the number of unwilling occurrences. The previous establishment of those items of radioprotection, with its respective grade, excluded subjective and personal values in the judgement and technical evaluation of the institutions. (author)

  14. Evaluation of the eddy-current method of inspecting steam generator tubing

    International Nuclear Information System (INIS)

    Flora, J.H.; Brown, S.D.; Weeks, J.R.

    1976-01-01

    The objective of this project has been to evaluate the eddy-current method of inspecting steam generator tubing by conducting a series of laboratory experiments with conventional eddy-current equipment. The experiments have involved obtaining eddy-current measurements on samples of 7/8-inch OD Inconel-600 tubing provided by the Westinghouse Nuclear Energy Systems Division. A variety of machined defects and some chemically induced flaws, such as stress corrosion cracks were fabricated in the tubing. Statistical evaluation of the data was employed to estimate the error encountered in measuring corrosion defects of various depths. It appears that the eddy-current technique can provide a reasonable measure of defect depth under certain conditions. On the other hand, the evaluation indicates that it is difficult to determine the depth of certain types of flaws with reliability and precision. Furthermore, although some defects as shallow as 10 percent of the tube wall could be detected, it was not possible to detect other types of flaws that were less than 40 percent deep even when the tube supports were not near the defects. The difficulty in detecting small volume flaws is attributed to low signal-to-noise ratio. Noise is a result of unwanted signals from test variables, such as wobble and variations in tube properties. The error in measurement of certain types of larger defects is associatedin part with test variables and also with the effects that the geometry of the defect has on the eddy-current signal patterns. The distortions in signal patterns caused by gradual wastage type defects and the poor reproducibility of signal patterns obtained from notches that represent stress corrosion cracks are described. Some developments that will rectify these detection and depth measurement problems are discussed

  15. Inspection Methods for Physical Protection Project: annual report, March-December 1981

    International Nuclear Information System (INIS)

    Bowden, D.D.; Green, J.N.; Minichino, C.; Thatcher, R.M.; Tyler, G.C.

    1982-01-01

    The report details the current production status of the expanded replacement inspection procedures for physical protection of power reactors, for strategic special nuclear material fixed sites, and for transportation of special nuclear material. In addition to the expanded replacement procedures, the final production status is reported for the new series of inspection procedures for special nuclear material of moderate and low strategic significance at fixed sites, for personnel training and qualifications plan (Appendix B to 10 CFR 73), for safeguards contingency plan (Appendix C to 10 CFR 73), and for licensee implementing procedures evaluation. Other deliverables, trips, management meetings, training, and changes in personnel are discussed

  16. Software Formal Inspections Guidebook

    Science.gov (United States)

    1993-01-01

    The Software Formal Inspections Guidebook is designed to support the inspection process of software developed by and for NASA. This document provides information on how to implement a recommended and proven method for conducting formal inspections of NASA software. This Guidebook is a companion document to NASA Standard 2202-93, Software Formal Inspections Standard, approved April 1993, which provides the rules, procedures, and specific requirements for conducting software formal inspections. Application of the Formal Inspections Standard is optional to NASA program or project management. In cases where program or project management decide to use the formal inspections method, this Guidebook provides additional information on how to establish and implement the process. The goal of the formal inspections process as documented in the above-mentioned Standard and this Guidebook is to provide a framework and model for an inspection process that will enable the detection and elimination of defects as early as possible in the software life cycle. An ancillary aspect of the formal inspection process incorporates the collection and analysis of inspection data to effect continual improvement in the inspection process and the quality of the software subjected to the process.

  17. Establishment of effective maintenance method based on the superior inspection technique for the deteriorating hot laboratory exhaust stack

    International Nuclear Information System (INIS)

    Mizukoshi, Yasutaka; Yasu, Tetsunori

    2012-06-01

    The Materials Monitoring Facility is equipped with an exhaust stack to emit air from a controlled area (the hot laboratory) into the atmosphere. Cracks and exfoliation have been observed for the surface of the exhaust stack, which is made of reinforced concrete and was constructed on the seacoast about 25 years ago, so exposed to a salt-corrosive condition. In order to get details of the present condition of the exhaust stack, an inspection was carried out using an electromagnetic wave radar method and chloride content method. Cracks and exfoliation were observed for the whole stack surface, especially for high positions. Moreover, salt damage was observed for the outer surface of the exhaust stack, and it was estimated that the infiltration of the chloride content was about 17 mm. Based on this detailed inspection of the exhaust stack, maintenance and repair work were carried out. (author)

  18. 46 CFR 160.010-7 - Methods of sampling, inspections and tests.

    Science.gov (United States)

    2010-10-01

    ... laboratory must inspect the place of manufacture, observe the various operations involved in the construction... section. (g) Painter attachment strength test. The apparatus must be positioned with its painter attachment fitting at the lowest point of the apparatus, directly below the center of buoyancy. The apparatus...

  19. Method of Characteristic (MOC) Nozzle Flowfield Solver - User’s Guide and Input Manual Version 2.0

    Science.gov (United States)

    2018-01-01

    TECHNICAL REPORT RDMR-SS-17-13 METHOD OF CHARACTERISTIC (MOC) NOZZLE FLOWFIELD SOLVER—USER’S GUIDE AND INPUT MANUAL VERSION 2.0 Kevin D. Kennedy...1 II. PROGRAM READS AND WRITES ...2 B. Program Reads .................................................................................................. 4 C. Program Writes

  20. Optical Inspection In Hostile Industrial Environments: Single-Sensor VS. Imaging Methods

    Science.gov (United States)

    Cielo, P.; Dufour, M.; Sokalski, A.

    1988-11-01

    On-line and unsupervised industrial inspection for quality control and process monitoring is increasingly required in the modern automated factory. Optical techniques are particularly well suited to industrial inspection in hostile environments because of their noncontact nature, fast response time and imaging capabilities. Optical sensors can be used for remote inspection of high temperature products or otherwise inaccessible parts, provided they are in a line-of-sight relation with the sensor. Moreover, optical sensors are much easier to adapt to a variety of part shapes, position or orientation and conveyor speeds as compared to contact-based sensors. This is an important requirement in a flexible automation environment. A number of choices are possible in the design of optical inspection systems. General-purpose two-dimensional (2-D) or three-dimensional (3-D) imaging techniques have advanced very rapidly in the last years thanks to a substantial research effort as well as to the availability of increasingly powerful and affordable hardware and software. Imaging can be realized using 2-D arrays or simpler one-dimensional (1-D) line-array detectors. Alternatively, dedicated single-spot sensors require a smaller amount of data processing and often lead to robust sensors which are particularly appropriate to on-line operation in hostile industrial environments. Many specialists now feel that dedicated sensors or clusters of sensors are often more effective for specific industrial automation and control tasks, at least in the short run. This paper will discuss optomechanical and electro-optical choices with reference to the design of a number of on-line inspection sensors which have been recently developed at our institute. Case studies will include real-time surface roughness evaluation on polymer cables extruded at high speed, surface characterization of hot-rolled or galvanized-steel sheets, temperature evaluation and pinhole detection in aluminum foil, multi

  1. Manual muscle testing: a method of measuring extremity muscle strength applied to critically ill patients.

    Science.gov (United States)

    Ciesla, Nancy; Dinglas, Victor; Fan, Eddy; Kho, Michelle; Kuramoto, Jill; Needham, Dale

    2011-04-12

    Survivors of acute respiratory distress syndrome (ARDS) and other causes of critical illness often have generalized weakness, reduced exercise tolerance, and persistent nerve and muscle impairments after hospital discharge. Using an explicit protocol with a structured approach to training and quality assurance of research staff, manual muscle testing (MMT) is a highly reliable method for assessing strength, using a standardized clinical examination, for patients following ARDS, and can be completed with mechanically ventilated patients who can tolerate sitting upright in bed and are able to follow two-step commands. (7, 8) This video demonstrates a protocol for MMT, which has been taught to ≥ 43 research staff who have performed >800 assessments on >280 ARDS survivors. Modifications for the bedridden patient are included. Each muscle is tested with specific techniques for positioning, stabilization, resistance, and palpation for each score of the 6-point ordinal Medical Research Council scale. Three upper and three lower extremity muscles are graded in this protocol: shoulder abduction, elbow flexion, wrist extension, hip flexion, knee extension, and ankle dorsiflexion. These muscles were chosen based on the standard approach for evaluating patients for ICU-acquired weakness used in prior publications. (1,2).

  2. A Kinematic Study of Prosodic Structure in Articulatory and Manual Gestures: Results from a Novel Method of Data Collection

    Directory of Open Access Journals (Sweden)

    Jelena Krivokapić

    2017-03-01

    Full Text Available The primary goal of this work is to examine prosodic structure as expressed concurrently through articulatory and manual gestures. Specifically, we investigated the effects of phrase-level prominence (Experiment 1 and of prosodic boundaries (Experiments 2 and 3 on the kinematic properties of oral constriction and manual gestures. The hypothesis guiding this work is that prosodic structure will be similarly expressed in both modalities. To test this, we have developed a novel method of data collection that simultaneously records speech audio, vocal tract gestures (using electromagnetic articulometry and manual gestures (using motion capture. This method allows us, for the first time, to investigate kinematic properties of body movement and vocal tract gestures simultaneously, which in turn allows us to examine the relationship between speech and body gestures with great precision. A second goal of the paper is thus to establish the validity of this method. Results from two speakers show that manual and oral gestures lengthen under prominence and at prosodic boundaries, indicating that the effects of prosodic structure extend beyond the vocal tract to include body movement.1

  3. Development of technology for the in-service inspection of reactor pressure vessel metal condition using a magnetic method

    International Nuclear Information System (INIS)

    Bakirov, M. B.; Zabruskov, N.Y; Massoud, J.P.

    2002-01-01

    The opportunity to perform the inspection of condition of base metal and metal of welded joints of cladded vessels of PWR by non destructive methods is shown. The technique for on-site specimen-free testing is offered on the basis of sharing a kinetic hardness method and magnetic method. The results of studies of magnetic and mechanical properties of vessel steels in various condition after irradiation and thermal processing are submitted. It is shown, that the magnetic properties (first of all coercive force) are sensitive to change of structure of a material. (authors)

  4. Study on the ultrasonic inspection method using the full matrix capture for the in service railway wheel

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Jianping; Wang, Li; Zhang, Yu; Gao, Xiaorong; Wang, Zeyong; Peng, Chaoyong [NDT Research Center, School of Physical Science and Technology, Southwest Jiaotong University, Chengdu 610031 (China)

    2014-02-18

    The quality of wheel is especially important for the safety of high speed railway. In this paper, a new ultrasonic array inspection method, the Full Matrix Capture (FMC) has been studied and applied to the high speed railway wheel inspection, especially in the wheel web from the tread. Firstly, the principle of FMC and TFM algorithm is discussed, and then the new optimization is applied to the standard FMC; Secondly the fundamentals of optimization is described in detail and the performance is analyzed. Finally, the experiment has been built with a standard phased array block and railway wheel, and then the testing results are discussed and analyzed. It is demonstrated that this change for the ultrasonic data acquisition and image reconstruction has higher efficiency and lower cost comparing to the FMC's procedure.

  5. Automation of inspection methods for eddy current testing of steam generator tubes

    International Nuclear Information System (INIS)

    Meurgey, P.; Baumaire, A.

    1990-01-01

    Inspection of all the tubes of a steam generator when the reactor is stopped is required for some of these exchangers affected by stress corrosion cracking. Characterization of each crack, in each tube is made possible by the development of software for processing the signals from an eddy current probe. The ESTELLE software allows a rapid increase of tested tubes, more than 80,000 in 1989 [fr

  6. Method and apparatus for the handling and inspection of a nuclear reactor fuel element

    International Nuclear Information System (INIS)

    Jabsen, F.S.

    1975-01-01

    The non-destructive inspection, for instance, of spent fuel elements and their dismantling are carried out under water in a pool. For this purpose, the fuel elements are attached to a bar which can be moved under water from the vertical into horizontal directions by means of a winch. The bar proper is suspended from a bridge spanning the pool. On one side, the bar is pivoted in a pin installed in components suspended from the bridge, whilst the movement of the bar is limited by a horizontal stop. In the vertical position, the fuel elements and components, respectively, such as fuel elements, are taken up and inspected in the horizontal position by means of TV systems or periscopes. The fuel elements are conveyed by a trolley. Dismantling of the fuel elements under water is carried out by special tools, such as cranks and connecting rods which, inter alia, put the individual fuel rods onto grids prior to inspection, disengage the clamps by means of grid disconnecting systems, remove the fuel rods from the grids and put them on the bars. (DG/RF) [de

  7. P-scan, a new system for ultrasonic weld inspection

    International Nuclear Information System (INIS)

    Lund, S.A.; Iversen, S.E.; Holst, H.

    1978-01-01

    The P-scan method is explained. It is described how the new P-scan system improves the ultrasonic method by adding means for visualization, data storage and documentation. Three different scanners are described: One designed for manual operation, another for automatic operation and a third for semiautomatic operation. The p'scan image of an ultrasonically examined test plate is presented and discussed. The variable Display Level (i.e. the inspection sensitivity) facility is described. The main advantage of this facility is the fact that the level can be varied at any time after the inspection. (orig.) [de

  8. Detection of Harmful Algal Toxins Using the Radioligand Receptor Binding Assay. A Manual of Methods

    International Nuclear Information System (INIS)

    2013-12-01

    of significant national, regional and interregional capabilities in algal toxin detection and monitoring, and management and mitigation of HABs associated with paralytic shellfish poisoning, diarrheic shellfish poisoning and ciguatera poisoning. In order to support and to facilitate the continuing effort of Member States to acquire, develop and sustain capabilities to address the impacts of HABs, the IAEA has taken the initiative to conceive and produce this manual of radioligand receptor binding assay methods. This is the first publication produced in collaboration with the NOAA and the Intergovernmental Oceanographic Commission of UNESCO (IOC UNESCO), the Philippine Nuclear Research Institute (an IAEA collaborating centre) and the Institut Louis Malarde in French Polynesia. It complements the Manual on Phytoplankton Sampling Techniques produced under the regional project RLA7014 and published by the IOC UNESCO. The series of well established nuclear techniques for early identification and quantification of HAB related toxins that are presented in this publication are intended to reduce the health and socioeconomic impacts of HAB events. The end users include national phytoplankton monitoring programmes with benefits to fisheries, research scientists, public health, communities, etc

  9. RBI - Risk Based Inspection: new technologies and methods applied to inspections of FPSO (Floating Production, Storage and Offloading Vessel) hull; IBR - Inspecao Baseada em Risco: novas tecnologias e metodos aplicados as inspecoes de casco de FPSOs

    Energy Technology Data Exchange (ETDEWEB)

    Farias, Bruno de; Figueiredo, Eduardo; Luiz, Marcio [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil); Meurer, Gustavo; Duarte, Romulo; Oliveira, Thais; Krzonkalla, Viviane [ABS Consulting, Rio de Janeiro, RJ (Brazil)

    2008-07-01

    With the aging of the FPSO's, which are fundamental to the operation Offshore, better techniques and technologies must be applied to assess more accurately the actual efficiency and structural conditions of producing unit. With the emergence of new engineering techniques and equipment and methods of structural inspection, is now possible to use these new technologies to better manage risk and reliability of the structure of the FPSO, with that, the inspections and methods are more rational and efficient. The Risk-Based Inspection is the tool for monitoring operation of industrial plants with systemic use of technology in conjunction with risk analysis and reliability. His concept is applicable to various branches of industry. The companies began their implementation of oil by refineries. The group of ABS Consulting with PETROBRAS has been developing and implementing these new technologies in inspections of hulls of FPSO's. Applied successfully in the units of the Campos basin, these methods are used by the group of Risk-Based Inspection to improve the efficiency of all the steps involved with the structural integrity of the unit. (author)

  10. Electromagnetic methods for measuring materials properties of cylindrical rods and array probes for rapid flaw inspection

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Haiyan [Iowa State Univ., Ames, IA (United States)

    2005-01-01

    The case-hardening process modifies the near-surface permeability and conductivity of steel, as can be observed through changes in alternating current potential drop (ACPD) along a rod. In order to evaluate case depth of case hardened steel rods, analytical expressions are derived for the alternating current potential drop on the surface of a homogeneous rod, a two-layered and a three-layered rod. The case-hardened rod is first modeled by a two-layer rod that has a homogeneous substrate with a single, uniformly thick, homogeneous surface layer, in which the conductivity and permeability values differ from those in the substrate. By fitting model results to multi-frequency ACPD experimental data, estimates of conductivity, permeability and case depth are found. Although the estimated case depth by the two-layer model is in reasonable agreement with the effective case depth from the hardness profile, it is consistently higher than the effective case depth. This led to the development of the three-layer model. It is anticipated that the new three-layered model will improve the results and thus makes the ACPD method a novel technique in nondestructive measurement of case depth. Another way to evaluate case depth of a case hardened steel rod is to use induction coils. Integral form solutions for an infinite rod encircled by a coaxial coil are well known, but for a finite length conductor, additional boundary conditions must be satisfied at the ends. In this work, calculations of eddy currents are performed for a two-layer conducting rod of finite length excited by a coaxial circular coil carrying an alternating current. The solution is found using the truncated region eigenfunction expansion (TREE) method. By truncating the solution region to a finite length in the axial direction, the magnetic vector potential can be expressed as a series expansion of orthogonal eigenfunctions instead of as a Fourier integral. Closed-form expressions are derived for the electromagnetic

  11. Remote inspection system for nuclear power plants

    International Nuclear Information System (INIS)

    Inagaki, K.; Fujii, M.; Doi, A.; Harima, T.

    1977-01-01

    A remote inspection system for nuclear power plants was constructed based on an analysis of inspections performed by an operator on patrol. This system consists of an operator's console and a remote station. The remote station, equipped with five kinds of sensors, is steered along the inspection route by a photoelectric guiding system or may be manually controlled from an operator's console in a main control room. Signals for control and inspection data are multiplexed and transmitted through a coaxial cable

  12. Procedure manual for the estimation of average indoor radon-daughter concentrations using the filtered alpha-track method

    International Nuclear Information System (INIS)

    George, J.L.

    1988-04-01

    One of the measurement needs of US Department of Energy (DOE) remedial action programs is the estimation of the annual-average indoor radon-daughter concentration (RDC) in structures. The filtered alpha-track method, using a 1-year exposure period, can be used to accomplish RDC estimations for the DOE remedial action programs. This manual describes the procedure used to obtain filtered alpha-track measurements to derive average RDC estimates from the measurrements. Appropriate quality-assurance and quality-control programs are also presented. The ''prompt'' alpha-track method of exposing monitors for 2 to 6 months during specific periods of the year is also briefly discussed in this manual. However, the prompt alpha-track method has been validated only for use in the Mesa County, Colorado, area. 3 refs., 3 figs

  13. In vitro culture of functionally active buffalo hepatocytes isolated by using a simplified manual perfusion method.

    Directory of Open Access Journals (Sweden)

    Santanu Panda

    Full Text Available In farm animals, there is no suitable cell line available to understand liver-specific functions. This has limited our understanding of liver function and metabolism in farm animals. Culturing and maintenance of functionally active hepatocytes is difficult, since they survive no more than few days. Establishing primary culture of hepatocytes can help in studying cellular metabolism, drug toxicity, hepatocyte specific gene function and regulation. Here we provide a simple in vitro method for isolation and short-term culture of functionally active buffalo hepatocytes.Buffalo hepatocytes were isolated from caudate lobes by using manual enzymatic perfusion and mechanical disruption of liver tissue. Hepatocyte yield was (5.3 ± 0.66×107 cells per gram of liver tissue with a viability of 82.3 ± 3.5%. Freshly isolated hepatocytes were spherical with well contrasted border. After 24 hours of seeding onto fibroblast feeder layer and different extracellular matrices like dry collagen, matrigel and sandwich collagen coated plates, hepatocytes formed confluent monolayer with frequent clusters. Cultured hepatocytes exhibited typical cuboidal and polygonal shape with restored cellular polarity. Cells expressed hepatocyte-specific marker genes or proteins like albumin, hepatocyte nuclear factor 4α, glucose-6-phosphatase, tyrosine aminotransferase, cytochromes, cytokeratin and α1-antitrypsin. Hepatocytes could be immunostained with anti-cytokeratins, anti-albumin and anti α1-antitrypsin antibodies. Abundant lipid droplets were detected in the cytosol of hepatocytes using oil red stain. In vitro cultured hepatocytes could be grown for five days and maintained for up to nine days on buffalo skin fibroblast feeder layer. Cultured hepatocytes were viable for functional studies.We developed a convenient and cost effective technique for hepatocytes isolation for short-term culture that exhibited morphological and functional characteristics of active hepatocytes

  14. Examination of pulsed eddy current for inspection of second layer aircraft wing lap-joint structures using outlier detection methods

    Energy Technology Data Exchange (ETDEWEB)

    Butt, D.M., E-mail: Dennis.Butt@forces.gc.ca [Royal Military College of Canada, Dept. of Chemistry and Chemical Engineering, Kingston, Ontario (Canada); Underhill, P.R.; Krause, T.W., E-mail: Thomas.Krause@rmc.ca [Royal Military College of Canada, Dept. of Physics, Kingston, Ontario (Canada)

    2016-09-15

    Ageing aircraft are susceptible to fatigue cracks at bolt hole locations in multi-layer aluminum wing lap-joints due to cyclic loading conditions experienced during typical aircraft operation, Current inspection techniques require removal of fasteners to permit inspection of the second layer from within the bolt hole. Inspection from the top layer without fastener removal is desirable in order to minimize aircraft downtime while reducing the risk of collateral damage. The ability to detect second layer cracks without fastener removal has been demonstrated using a pulsed eddy current (PEC) technique. The technique utilizes a breakdown of the measured signal response into its principal components, each of which is multiplied by a representative factor known as a score. The reduced data set of scores, which represent the measured signal, are examined for outliers using cluster analysis methods in order to detect the presence of defects. However, the cluster analysis methodology is limited by the fact that a number of representative signals, obtained from fasteners where defects are not present, are required in order to perform classification of the data. Alternatively, blind outlier detection can be achieved without having to obtain representative defect-free signals, by using a modified smallest half-volume (MSHV) approach. Results obtained using this approach suggest that self-calibrating blind detection of cyclic fatigue cracks in second layer wing structures in the presence of ferrous fasteners is possible without prior knowledge of the sample under test and without the use of costly calibration standards. (author)

  15. Examination of pulsed eddy current for inspection of second layer aircraft wing lap-joint structures using outlier detection methods

    International Nuclear Information System (INIS)

    Butt, D.M.; Underhill, P.R.; Krause, T.W.

    2016-01-01

    Ageing aircraft are susceptible to fatigue cracks at bolt hole locations in multi-layer aluminum wing lap-joints due to cyclic loading conditions experienced during typical aircraft operation, Current inspection techniques require removal of fasteners to permit inspection of the second layer from within the bolt hole. Inspection from the top layer without fastener removal is desirable in order to minimize aircraft downtime while reducing the risk of collateral damage. The ability to detect second layer cracks without fastener removal has been demonstrated using a pulsed eddy current (PEC) technique. The technique utilizes a breakdown of the measured signal response into its principal components, each of which is multiplied by a representative factor known as a score. The reduced data set of scores, which represent the measured signal, are examined for outliers using cluster analysis methods in order to detect the presence of defects. However, the cluster analysis methodology is limited by the fact that a number of representative signals, obtained from fasteners where defects are not present, are required in order to perform classification of the data. Alternatively, blind outlier detection can be achieved without having to obtain representative defect-free signals, by using a modified smallest half-volume (MSHV) approach. Results obtained using this approach suggest that self-calibrating blind detection of cyclic fatigue cracks in second layer wing structures in the presence of ferrous fasteners is possible without prior knowledge of the sample under test and without the use of costly calibration standards. (author)

  16. Continuous Manual Exchange Transfusion for Patients with Sickle Cell Disease: An Efficient Method to Avoid Iron Overload.

    Science.gov (United States)

    Koehl, Bérengère; Missud, Florence; Holvoet, Laurent; Ithier, Ghislaine; Sakalian-Black, Oliver; Haouari, Zinedine; Lesprit, Emmanuelle; Baruchel, André; Benkerrou, Malika

    2017-03-14

    Children with sickle cell anemia (SCA) may be at risk of cerebral vasculopathy and strokes, which can be prevented by chronic transfusion programs. Repeated transfusions of packed red blood cells (PRBCs) is currently the simplest and most used technique for chronic transfusion programs. However, iron overload is one of the major side effects of this therapy. More developed methods exist, notably the apheresis of RBC (erythrapheresis), which is currently the safest and most efficient method. However, it is costly, complicated, and cannot be implemented everywhere, nor is it suitable for all patients. Manual exchange transfusions combine one or more manual phlebotomies with a PRBC transfusion. At the Reference Center of Sickle Cell Disease, we set up a continuous method of manual exchange transfusion that is feasible for all hospital settings, demands no specific equipment, and is widely applicable. In terms of HbS decrease, stroke prevention, and iron overload prevention, this method showed comparable efficiency to erythrapheresis. In cases where erythrapheresis is not available, this method can be a good alternative for patients and care centers.

  17. Comparison between different methods for inspection of wooden poles in service in electricity distribution networks; Comparacao entre diferentes metodos de inspecao de postes de madeira em servico em redes de distribuicao de energia

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, M.A.O.; Pires, M.; Dedavid, B.A.; Vidor, F.L.R.; Oliveira, W.S.; Abruzzi, R.C. [Pontificia Univ. Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil). Programa de Pos-Graduacao em Engenharia e Tecnologia de Materiais (PGETEMA)], Email: mpires@pucrs.br

    2010-07-01

    The pole is the main support structure of the electric network and should be inspected regularly to ensure system security. The aim of this study is to compare traditional and instrumental inspection methods of the wooden poles in service in AES Sul power distribution network (Montenegro, RS). The inspections were conducted in about 180 poles in two measurement campaigns (2001 and 2010). The procedure was based on the traditional inspection (visual inspection, percussion and effort lateral) and instrumental method based on Polux equipment that measures the penetration resistance and moisture content of wood. The results were compared in search of assertiveness of the methods used to subsidize the standardization of inspection procedures. (author)

  18. Developments in mechanical ultrasonic inspection and qualification of NDE

    International Nuclear Information System (INIS)

    Kauppinen, P.; Pitkaenen, J.; Kuusinen, P.

    2001-01-01

    Reliability of non-destructive testing results has a direct influence on structural integrity assessment and safety of the inspected structures e.g. NPP primary circuit pressure boundaries. Advanced technology together with highly skilled and experienced personnel is required. One of the current trends is automation. Mechanised equipment can replace tedious manual work in positioning and moving of the transducers. Large areas can be scanned, analysed and numerically documented for direct comparison of eventual later repeated inspections. Another major trend is qualification, which aims to ensure that the inspection results are correct and fit the purpose. The suitability and proper operation of equipment, methods and personnel i.e. the whole chain shall be proven. This presentation summarises the advances in automation and qualification of non-destructive inspection during the second project year, Monitoring of material degradation was included in the studied topics and will also be shortly described. (author)

  19. Two kinds of manual chopping methods applied in small incision extracapsular cataract extraction

    Directory of Open Access Journals (Sweden)

    Xia Jiang

    2016-02-01

    Full Text Available AIM:To research clinical effect of two manual chopping methods for small incision extracapsular cataract extraction. METHODS: We observed 143 cases(184 eyeswith grade Ⅳ or higher taken the small incision cataract extraction and intraocular lens implantation. Patients were given randomly knifed chopping with closed hook(92 eyesor double knifed chopping(92 eyes. The intra-operative posterior capsule rupture was observed and compared. At 1d, 1wk and 1mo postoperatively, visual acuity, corneal edema and corneal astigmatism were observed and analyzed. RESULTS:There were 10 eyes in patients accepting knifed chopping with closed hook with intra-operative posterior capsule rupture and 1 eye in patients accepting double knifed chopping. The difference between the two groups was statistically significant. The visual acuity of patients accepting knifed chopping with closed hook(92 eyesat 1d postoperatively was 0.380±0.105, and that of patients accepting double knifed chopping(92 eyeswas 0.420±0.095; the difference between the two groups was statistically significant. The visual acuity of patients accepting knifed chopping with closed hook(84 eyesat 1wk postoperatively was 0.480±0.123, and that of patients accepting double knifed chopping(86 eyeswas 0.520±0.085; the difference between the two groups was statistically significant. The visual acuity of patients accepting knifed chopping with closed hook(60 eyesat 1mo postoperatively was 0.610±0.083, and that of patients accepting double knifed chopping(52 eyeswas 0.643±0.072; the difference between the two groups was not statistically significant. The differences on corneal edema and corneal astigmatism between the two methods at 1d, 1wk and 1mo postoperatively were not statistically significant. CONCLUSION:The application of knifed chopping with closed hook and double knifed chopping in small incision extracapsular cataract extraction and intraocular lens implantation can effectively treat with

  20. The photothermal camera - a new non destructive inspection tool; La camera photothermique - une nouvelle methode de controle non destructif

    Energy Technology Data Exchange (ETDEWEB)

    Piriou, M. [AREVA NP Centre Technique SFE - Zone Industrielle et Portuaire Sud - BP13 - 71380 Saint Marcel (France)

    2007-07-01

    The Photothermal Camera, developed by the Non-Destructive Inspection Department at AREVA NP's Technical Center, is a device created to replace penetrant testing, a method whose drawbacks include environmental pollutants, industrial complexity and potential operator exposure. We have already seen how the Photothermal Camera can work alongside or instead of conventional surface inspection techniques such as penetrant, magnetic particle or eddy currents. With it, users can detect without any surface contact ligament defects or openings measuring just a few microns on rough oxidized, machined or welded metal parts. It also enables them to work on geometrically varied surfaces, hot parts or insulating (dielectric) materials without interference from the magnetic properties of the inspected part. The Photothermal Camera method has already been used for in situ inspections of tube/plate welds on an intermediate heat exchanger of the Phenix fast reactor. It also replaced the penetrant method for weld inspections on the ITER vacuum chamber, for weld crack detection on vessel head adapter J-welds, and for detecting cracks brought on by heat crazing. What sets this innovative method apart from others is its ability to operate at distances of up to two meters from the inspected part, as well as its remote control functionality at distances of up to 15 meters (or more via Ethernet), and its emissions-free environmental cleanliness. These make it a true alternative to penetrant testing, to the benefit of operator and environmental protection. (author) [French] La Camera Photothermique, developpee par le departement des Examens Non Destructifs du Centre Technique de AREVA NP, est un equipement destine a remplacer le ressuage, source de pollution pour l'environnement, de complexite pour l'industrialisation et eventuellement de dosimetrie pour les operateurs. Il a ete demontre que la Camera Photothermique peut etre utilisee en complement ou en remplacement des

  1. Development of a NDI system using the magneto-optical method. 2. Remote sensing using the novel magneto-optical inspection system

    International Nuclear Information System (INIS)

    Lee, Jinyi; Shoji, Tetsuo

    1999-01-01

    A new remote sensing system using the magneto-optical method is developed for inspection of flaws introduced during service operation where routine inspection is difficult because of difficult inaccessibility to the components. Among the advantages of non-destructive inspection (NDI) based on the magneto-optical sensor are: real time inspection, elimination of electrical noise and high spatial resolution. Remote sensing of flaws is achieved using the basic principles of Faraday effect, optical permeability, and diffraction of a laser by the domain walls. This paper describes a novel remote NDI system using the principles of optics and LMF. The main characteristic of the system is that image data and LMF information can be obtained simultaneously. It is possible to carry out remote and high speed inspection of cracks from the intensity of reflected light, and to estimate the size of a crack effectively with their diverse data. The advantages of this NDI system are demonstrated using two specimens. (author)

  2. A novel method for rapid inspection of sewer networks: combining acoustic and optical means

    OpenAIRE

    Plihal, H.; Kretschmer, F.; Bin Ali, M.T.; See, C.H.; Romanova, A.; Horoshenkov, K.V.; Ertl, T.

    2015-01-01

    Operation and maintenance of the public sewer system represent key tasks for an\\ud operator. Condition assessment is usually conducted by conventional closed\\ud circuit television (CCTV) inspection. However, alternative tools such as\\ud manhole-zoom cameras (MZCs) and the acoustic technology SewerBatt® are\\ud available today.\\ud The INNOKANIS project investigates structural and operational condition\\ud assessment in the sewer system by means of 3 MZC models and SewerBatt® to\\ud develop a comb...

  3. A fast position estimation method for a control rod guide tube inspection robot with a single camera

    International Nuclear Information System (INIS)

    Lee, Jae C.; Seop, Jun H.; Choi, Yu R.; Kim, Jae H.

    2004-01-01

    One of the problems in the inspection of control rod guide tubes using a mobile robot is accurate estimation of the robot's position. The problem is usually explained by the question 'Where am I?'. We can solve this question by a method called dead reckoning using odometers. But it has some inherent drawbacks such that the position error grows without bound unless an independent reference is used periodically to reduce the errors. In this paper, we presented one method to overcome this drawback by using a vision sensor. Our method is based on the classical Lucas Kanade algorithm for on image tracking. In this algorithm, an optical flow must be calculated at every image frame, thus it has intensive computing load. In order to handle large motions, it is preferable to use a large integration window. But a small integration window is more preferable to keep the details contained in the images. We used the robot's movement information obtained from the dead reckoning as an input parameter for the feature tracking algorithm in order to restrict the position of an integration window. By means of this method, we could reduce the size of an integration window without any loss of its ability to handle large motions and could avoid the trade off in the accuracy. And we could estimate the position of our robot relatively fast without on intensive computing time and the inherent drawbacks mentioned above. We studied this algorithm for applying it to the control rod guide tubes inspection robot and tried an inspection without on operator's intervention

  4. Technical Letter Report - Preliminary Assessment of NDE Methods on Inspection of HDPE Butt Fusion Piping Joints for Lack of Fusion

    International Nuclear Information System (INIS)

    Crawford, Susan L.; Cumblidge, Stephen E.; Doctor, Steven R.; Hall, Thomas E.; Anderson, Michael T.

    2008-01-01

    The U.S. Nuclear Regulatory Commission (NRC) has a multi-year program at the Pacific Northwest National Laboratory (PNNL) to provide engineering studies and assessments of issues related to the use of nondestructive evaluation (NDE) methods for the reliable inspection of nuclear power plant components. As part of this program, there is a subtask 2D that was set up to address an assessment of issues related to the NDE of high density polyethylene (HDPE) butt fusion joints. This work is being driven by the nuclear industry wanting to employ HDPE materials in nuclear power plant systems. This being a new material for use in nuclear applications, there are a number of issues related to its use and potential problems that may evolve. The industry is pursuing ASME Code Case N-755 entitled 'Use of Polyethylene (PE) Plastic Pipe for Section III, Division 1, Construction and Section XI Repair/Replacement Activities' that contains the requirements for nuclear power plant applications of HDPE. This Code Case requires that inspections be performed after the fusion joint is made by visually examining the bead that is formed and conducting a pressure test of the joint. These tests are only effective in general if gross through-wall flaws exist in the fusion joint. The NRC wants to know whether a volumetric inspection can be conducted on the fusion joint that will reliably detect lack-of-fusion conditions that may be produced during joint fusing. The NRC has requested that the work that PNNL is conducting be provided to assist them in resolving this inspection issue of whether effective volumetric NDE can be conducted to detect lack of fusion (LOF) in the butt HDPE joints. PNNL had 24 HDPE pipe specimens manufactured of 3408 material to contain LOF conditions that could be used to assess the effectiveness of NDE in detecting the LOF. Basic ultrasonic material properties were measured and used to guide the use of phased arrays and time-of-flight diffraction (TOFD) work that was

  5. Study of an alternative method for inspection of rods with UO{sub 2} pellets early manufactured

    Energy Technology Data Exchange (ETDEWEB)

    Carnaval, João Paulo R.; Oliveira, Carlos A.; Beltran, Dalton J.M.C., E-mail: joaocarnaval@inb.gov.br, E-mail: carlossilva@inb.gov.br, E-mail: daltonbeltran@inb.gov.br [Indústrias Nucleares do Brasil S.A. (INB), Resende, RJ (Brazil). Gerência de Engenharia do Produto e Gerência de Análise do Combustível

    2017-07-01

    The inspection of the fuel rods manufactured at INB, for production of fuel assemblies, is based on a group of scintillators detectors in series scanning the products. These detectors capture the gamma rays emitted on the decay of uranium isotopes (passive measurement) and determine the enrichment level ({sup 235}U weight percent) of the UO{sub 2} pellets inside the fuel rods. During the inspection of fuel rods for Angra-1 21{sup st} Reload, it was found that the 2.6% {sup 235}U and 4.15% {sup 235}U pellets stacks behave as 2.6% {sup 235}U only. The investigation of this event allowed to conclude that the measurement of enrichment may be affected by the loss of the secular equilibrium among uranium isotopes and their decay products caused by the AUC precipitation during the UO{sub 2} powder and pellet fabrication. Therefore, the spectrum background created by Compton scattering, inside Rod Scanner detectors, from high energies of {sup 238}U products decay affect the {sup 235}U% measurement. After continuous measurements, the 2.6% {sup 235}U and 4.15% {sup 235}U pellets stacks became distinguished and the results were used to calculate an 'equilibrium factor'. It was concluded that after 35 days the UO{sub 2} powder should reach approximately 60% of secular equilibrium reinstatement and the rods assembled with the pellets produced from this powder would be adequate for inspection on Rod Scanner. It was concluded that would be possible to achieve the equilibrium factor by blending a lot of UO{sub 2} powder manufactured a long time ago (old powder) with another lot early manufactured (young powder) resulting in a lot which would provide pellets and, consequently, rods adequate for inspection by Rod Scanner. This work presents a study of an alternative method to perform the inspection of fuel rods with UO{sub 2} pellets early manufactured aiming to provide quality assurance for the product. (author)

  6. Inspection Database

    Data.gov (United States)

    U.S. Department of Health & Human Services — FDA is disclosing the final inspection classification for inspections related to currently marketed FDA-regulated products. The disclosure of this information is not...

  7. Inspection Method for Contact Condition of Soil on the Surface of Underground Pipe Utilizing Resonance of Transverse Lamb Wave

    Science.gov (United States)

    Tanigawa, Hiroshi; Seno, Hiroaki; Watanabe, Yoshiaki; Nakajima, Koshiro

    1998-05-01

    A nondestructive inspection method to estimate the contact condition of soil on the surface of an underground pipe, utilizing the resonance of a transverse Lamb wave circulating along the pipe wall is proposed.The Q factor of the resonance is considered and measured under some contact conditions by sweeping the vibrating frequency in a 150-mm-inner diameter Fiberglass Reinforced Plastic Mortar (FRPM) pipe. It is confirmed that the Q factor shows a clear response to the change in the contact conditions. For example, the Q factor is 8.4 when the pipe is in ideal contact with the soil plane and goes up to 19.2 when a 100-mm-diameter void is located at the contact surface of the soil.The spatial resolution of the proposed inspection method is also measured by moving the sensing point along the direction of laying the length of the pipe into a 85-mm-diameter void. The resolution of the proposed method is estimated at about 50 mm.

  8. Optimization of an Optical Inspection System Based on the Taguchi Method for Quantitative Analysis of Point-of-Care Testing

    Directory of Open Access Journals (Sweden)

    Chia-Hsien Yeh

    2014-09-01

    Full Text Available This study presents an optical inspection system for detecting a commercial point-of-care testing product and a new detection model covering from qualitative to quantitative analysis. Human chorionic gonadotropin (hCG strips (cut-off value of the hCG commercial product is 25 mIU/mL were the detection target in our study. We used a complementary metal-oxide semiconductor (CMOS sensor to detect the colors of the test line and control line in the specific strips and to reduce the observation errors by the naked eye. To achieve better linearity between the grayscale and the concentration, and to decrease the standard deviation (increase the signal to noise ratio, S/N, the Taguchi method was used to find the optimal parameters for the optical inspection system. The pregnancy test used the principles of the lateral flow immunoassay, and the colors of the test and control line were caused by the gold nanoparticles. Because of the sandwich immunoassay model, the color of the gold nanoparticles in the test line was darkened by increasing the hCG concentration. As the results reveal, the S/N increased from 43.48 dB to 53.38 dB, and the hCG concentration detection increased from 6.25 to 50 mIU/mL with a standard deviation of less than 10%. With the optimal parameters to decrease the detection limit and to increase the linearity determined by the Taguchi method, the optical inspection system can be applied to various commercial rapid tests for the detection of ketamine, troponin I, and fatty acid binding protein (FABP.

  9. User Manuals for a Primary Care Electronic Medical Record System: A Mixed Methods Study of User- and Vendor-Generated Documents.

    Science.gov (United States)

    Shachak, Aviv; Dow, Rustam; Barnsley, Jan; Tu, Karen; Domb, Sharon; Jadad, Alejandro R; Lemieux-Charles, Louise

    2013-06-04

    Tutorials and user manuals are important forms of impersonal support for using software applications including electronic medical records (EMRs). Differences between user- and vendor documentation may indicate support needs, which are not sufficiently addressed by the official documentation, and reveal new elements that may inform the design of tutorials and user manuals. What are the differences between user-generated tutorials and manuals for an EMR and the official user manual from the software vendor? Effective design of tutorials and user manuals requires careful packaging of information, balance between declarative and procedural texts, an action and task-oriented approach, support for error recognition and recovery, and effective use of visual elements. No previous research compared these elements between formal and informal documents. We conducted an mixed methods study. Seven tutorials and two manuals for an EMR were collected from three family health teams and compared with the official user manual from the software vendor. Documents were qualitatively analyzed using a framework analysis approach in relation to the principles of technical documentation described above. Subsets of the data were quantitatively analyzed using cross-tabulation to compare the types of error information and visual cues in screen captures between user- and vendor-generated manuals. The user-developed tutorials and manuals differed from the vendor-developed manual in that they contained mostly procedural and not declarative information; were customized to the specific workflow, user roles, and patient characteristics; contained more error information related to work processes than to software usage; and used explicit visual cues on screen captures to help users identify window elements. These findings imply that to support EMR implementation, tutorials and manuals need to be customized and adapted to specific organizational contexts and workflows. The main limitation of the study

  10. User Manuals for a Primary Care Electronic Medical Record System: A Mixed Methods Study of User- and Vendor-Generated Documents

    Science.gov (United States)

    Dow, Rustam; Barnsley, Jan; Tu, Karen; Domb, Sharon; Jadad, Alejandro R.; Lemieux-Charles, Louise

    2015-01-01

    Research problem Tutorials and user manuals are important forms of impersonal support for using software applications including electronic medical records (EMRs). Differences between user- and vendor documentation may indicate support needs, which are not sufficiently addressed by the official documentation, and reveal new elements that may inform the design of tutorials and user manuals. Research question What are the differences between user-generated tutorials and manuals for an EMR and the official user manual from the software vendor? Literature review Effective design of tutorials and user manuals requires careful packaging of information, balance between declarative and procedural texts, an action and task-oriented approach, support for error recognition and recovery, and effective use of visual elements. No previous research compared these elements between formal and informal documents. Methodology We conducted an mixed methods study. Seven tutorials and two manuals for an EMR were collected from three family health teams and compared with the official user manual from the software vendor. Documents were qualitatively analyzed using a framework analysis approach in relation to the principles of technical documentation described above. Subsets of the data were quantitatively analyzed using cross-tabulation to compare the types of error information and visual cues in screen captures between user- and vendor-generated manuals. Results and discussion The user-developed tutorials and manuals differed from the vendor-developed manual in that they contained mostly procedural and not declarative information; were customized to the specific workflow, user roles, and patient characteristics; contained more error information related to work processes than to software usage; and used explicit visual cues on screen captures to help users identify window elements. These findings imply that to support EMR implementation, tutorials and manuals need to be customized and

  11. Example value-impact analysis of non-destructive examination methods used for inservice inspection of BWR piping

    International Nuclear Information System (INIS)

    Tabatabai, A.S.; Simonen, F.A.

    1985-12-01

    This paper describes work recently completed at Pacific Northwest Laboratory (PNL) to use value-impact (V/I) analysis methods to help guide research to improve the effectiveness of inservice inspection (ISI) procedures at nuclear power plants. The example developed at PNL uses the results of probabilistic fracture mechanics and probabilistic risk analysis (PRA) studies to compare three generic categories of non-destructive examination (NDE) methods. These NDE methods are used to detect possible pipe cracks such as those induced by intergranular stress corrosion (IGSCC). The results of the analysis of this example include (1) quantification of the effectiveness of ISI in increasing plant safety in terms of reduction in core-melt frequency, (2) estimates of the industry cost of performing ISI, (3) estimates of radiation exposures to plant personnel as a result of performing ISI, and (4) potential areas of improvement in the NDE and ISI process

  12. Inspection planning

    International Nuclear Information System (INIS)

    Korosec, D.; Levstek, M.F.

    2001-01-01

    Slovenian Nuclear Safety Administration (SNSA) division of nuclear and radiological safety inspection has developed systematic approach to their inspections. To be efficient in their efforts regarding regular and other types of inspections, in past years, the inspection plan has been developed. It is yearly based and organized on a such systematic way, that all areas of nuclear safety important activities of the licensee are covered. The inspection plan assures appropriate preparation for conducting the inspections, allows the overview of the progress regarding the areas to be covered during the year. Depending on the licensee activities and nature of facility (nuclear power plant, research reactor, radioactive waste storage, others), the plan has different levels of intensity of inspections and also their frequency. One of the basic approaches of the plan is to cover all nuclear and radiological important activities on such way, that all regulatory requests are fulfilled. In addition, the inspection plan is a good tool to improve inspection effectiveness based on previous experience and allows to have the oversight of the current status of fulfillment of planned inspections. Future improvement of the plan is necessary in the light of newest achievements on this field in the nuclear world, that means, new types of inspections are planned and will be incorporated into plan in next year.(author)

  13. Inspection method for solidification product of radioactive waste and method of preparing solidification product of radiation waste

    International Nuclear Information System (INIS)

    Izumida, Tatsuo; Tamada, Shin; Matsuda, Masami; Kamata, Shoji; Kikuchi, Makoto.

    1993-01-01

    A powerful X-ray generation device using an electron-ray accelerator is used for inspecting presence or absence of inner voids in solidification products of radioactive wastes during or after solidification. By installing the X-ray CT system and the radioactive waste solidifying facility together, CT imaging for solidification products is conducted in a not-yet cured state of solidifying materials during or just after the injection. If a defect that deteriorates the durability of the solidification products should be detected, the solidification products are repaired, for example, by applying vibrations to the not-yet cured solidification products. Thus, since voids or cracks in the radioactive wastes solidification products, which were difficult to be measured so far, can be measured in a short period of time accurately thereby enabling to judge adaptability to the disposal standards, inspection cost for the radioactive waste solidification product can be saved remarkably. Further, the inside of the radioactive waste solidification products can be evaluated correctly and visually, so that safety in the ground disposal storage of the radioactive solidification products can be improved remarkably. (N.H.)

  14. Manual Intracardiac Electrogram Method Is Accurate Alternative to Echocardiography for Atrioventricular and Interventricular Optimization in Cardiac Resynchronization Therapy.

    Science.gov (United States)

    Pezo Nikolić, Borka; Lovrić, Daniel; Ljubas Maček, Jana; Rešković Lukšić, Vlatka; Matasić, Richard; Šeparović Hanževački, Jadranka

    2017-12-01

    Some manufacturers do not provide automated intracardiac electrogram method (IEGM) systems for atrioventricular (AV) and interventricular (VV) delay optimization in cardiac resynchronization therapy (CRT). We aimed to evaluate the accuracy of manual IEGM method in 48 patients previously implanted with Medtronic Syncra CRT. All patients underwent standard device interrogation followed by CRT optimization by IEGM method and by echocardiography one month after implantation. The patient mean age was 60.7±11.8 years and there were 33 (68.8%) males. After CRT implantation, the left ventricular ejection fraction increased from 28.0±7.9% to 39.1±11.0% (p<0.001). Optimal aortic flow Velocity Time Integral (aVTI) was obtained when VV was set to 20-50 ms left ventricular pre-activation. There was a strong correlation between VV values determined by echocardiography and IEGM (R=0.823, p<0.001). We found no significant difference in AV, VV and aVTI values between echocardiography and IEGM method. However, IEGM was significantly less time-consuming than echocardiography [20 (10-28) vs. 40 (35-60) minutes, p<0.001]. Manual IEGM method may be good alternative to echocardiography and automated IEGM method. It also emphasizes the need for implementation of automated IEGM systems in as many CRT devices as possible.

  15. Automated visual inspection of moving custom parts

    CSIR Research Space (South Africa)

    Davrajh, S

    2008-01-01

    Full Text Available frequencies than batched produced parts. This higher frequency of inspection significantly impacts inspection times, and inherently, production rates. An effective, diverse, accurate, robust, and time efficient method for inspecting custom parts is therefore...

  16. Electrochemical methods for the inspection of reinforcement corrosion in concrete structures - field experience

    International Nuclear Information System (INIS)

    Elsener, B.; Boehni, H.

    1992-01-01

    Maintenance and planning of the restoration work on reinforced concrete structures need a rapid, non-destructive inspection technique that detects corrosion at an early stage. In this paper the field experience with electrochemical techniques are reported. The results of potential surveys on bridge decks of the Swiss highways, realized with a new computer controlled eight-wheel measurement system, clearly show that a fixed potential value (as proposed in ASTM C 876-87) for the identification and location of active corrosion of steel in concrete does not exist. A statistical elaboration of the potential data allows to identify the potential value for corroding and passive rebar for each structure individually. A rapid new technique using galvanostatic pulse measurements was tested successfully on site. It gives clear, unambiguous results on the corrosion state of the rebars when half-cell potentials are uncertain. In addition, the ohmic resistance and the apparent polarization resistance are determined from the evaluation of the transients. From these values the concrete resistivity and the actual corrosion rate of the rebars may be estimated

  17. Inspection and repairing method and device for inside of nuclear reactor

    International Nuclear Information System (INIS)

    Ito, Shin; Yuguchi, Yasuhiro; Sato, Katsuhiko

    1996-01-01

    A swimming robot handling device is disposed on a floor of a reactor pit floor or a reactor floor. A swimming robot is connected to a winding device of a composite cable incorporating optical fibers. The swimming robot comprises a robot propulsion device for propelling the robot itself, a laser beam irradiating optical device for irradiating pulsative laser beams introduced by an optical fiber and an antenna mechanism having ultrasonic probe in an antenna-like shape. The swimming robot is lowered in a reactor filled with water and caused to swim to a portion to be welded, and pulsative laser beams are irradiated to the portion to be welded in a state where the antenna mechanism is brought into contact with the portion to be welded to improve the state of stresses on the surface. Further, the ultrasonic oscillations generated upon irradiation of the laser beams are measured using the ultrasonic probe to perform physical inspection. The surface of the portion to be welded can be modified or repaired stably and efficiently by remote control. (N.H.)

  18. A study of the long-range inspection method for on-line monitoring of pipes in nuclear power plants

    International Nuclear Information System (INIS)

    Eom, Heung Seop; Lim, Sa Hoe; Kim, Jae Hee; Kim, Young H.; Song, Sung Jin

    2005-01-01

    Deployment of an advanced on-line monitoring of the component integrity offers the prospect of an improved performance, enhanced safety, and reduced overall cost for nuclear power plants (NPPs). Also ultrasonic guided ultrasonic wave has been known as one of the promising techniques that could be utilized for on-line monitoring, because it enables us to undertake a long-range inspection of structures such as plates and pipes. The present work is aimed at developing a new method using ultrasonic guided waves for the on-line monitoring of pipes. For this purpose we fabricated the necessary hardware and carried out transmitter tuning, group velocity measurement, receiver tuning, and mode identification. Finally we carried out an experiment on a long-range inspection with the developed hardware and the techniques. In the experiment, we could detect the flaws at a distance of about 20M from the transmitter, and we could verify the possibility of using the developed hardware and techniques for on-line monitoring of pipes in NPPs

  19. Modelling NDE pulse-echo inspection of misorientated planar rough defects using an elastic finite element method

    Energy Technology Data Exchange (ETDEWEB)

    Pettit, J. R.; Lowe, M. J. S. [UK Research Centre for NDE, Imperial College London, Exhibition Road, London, SW7 2AZ (United Kingdom); Walker, A. E. [Rolls-Royce Nuclear, PO BOX 2000, Derby, DE21 7XX (United Kingdom)

    2015-03-31

    Pulse-echo ultrasonic NDE examination of large pressure vessel forgings is a design and construction code requirement in the power generation industry. Such inspections aim to size and characterise potential defects that may have formed during the forging process. Typically these defects have a range of orientations and surface roughnesses which can greatly affect ultrasonic wave scattering behaviour. Ultrasonic modelling techniques can provide insight into defect response and therefore aid in characterisation. However, analytical approaches to solving these scattering problems can become inaccurate, especially when applied to increasingly complex defect geometries. To overcome these limitations a elastic Finite Element (FE) method has been developed to simulate pulse-echo inspections of embedded planar defects. The FE model comprises a significantly reduced spatial domain allowing for a Monte-Carlo based approach to consider multiple realisations of defect orientation and surface roughness. The results confirm that defects aligned perpendicular to the path of beam propagation attenuate ultrasonic signals according to the level of surface roughness. However, for defects orientated away from this plane, surface roughness can increase the magnitude of the scattered component propagating back along the path of the incident beam. This study therefore highlights instances where defect roughness increases the magnitude of ultrasonic scattered signals, as opposed to attenuation which is more often assumed.

  20. To a scientific substantiation of a practical method of inspection of radiating conditions on territories, polluted with atmospheric fallout

    International Nuclear Information System (INIS)

    Burmistrov, V.R; Makarenko, N.G.; Karimova, L.M.

    2001-01-01

    Full text: In the report a question on necessity of practical development of a method of inspection of radiating fields, adapted to a nature of pollution is put. 50-year study of radionuclides pollution, dropping out from atmosphere after nuclear tests or failures, have shown non-perspective of traditional techniques of inspection of a radiating conditions on large territories. The detailed measurements covering surface without gaps are very expensive, and use of a unloaded grid requires interpolation irregular mosaic structure. Detection Fractal structure at the analysis Chernobyl losses and pollution of fragments of Semipalatinsk test nuclear site specify necessity of the account of self-similar properties of pollution in philosophy of measurement. For realization of potential opportunities Fractal field the special circuit of measurements, distinguished from, is required standard. Fractal approach requires shooting with system of crossed vicinities on chosen detailed platforms, making a rather small part of surveyed territory. These data will allow to reveal scale laws, which are universal in a significant range of scales. Using scaling of small platforms, it is possible to receive correct estimation of structure of pollution of large territories. The stated above reasons are based on our experiments on fractal approach to the analysis of continuous shooting (aero-scale shooting of scale 1:5000) in a zone of Semipalatinsk test site on three platforms by the sizes on 1000x400 m 2 . Our results specify necessity revision almost of all conclusions, received earlier on the basis of traditional techniques

  1. IAEA safeguards technical manual

    International Nuclear Information System (INIS)

    1982-03-01

    Part F of the Safeguards Technical Manual is being issued in three volumes. Volume 1 was published in 1977 and revised slightly in 1979. Volume 1 discusses basic probability concepts, statistical inference, models and measurement errors, estimation of measurement variances, and calibration. These topics of general interest in a number of application areas, are presented with examples drawn from nuclear materials safeguards. The final two chapters in Volume 1 deal with problem areas unique to safeguards: calculating the variance of MUF and of D respectively. Volume 2 continues where Volume 1 left off with a presentation of topics of specific interest to Agency safeguards. These topics include inspection planning from a design and effectiveness evaluation viewpoint, on-facility site inspection activities, variables data analysis as applied to inspection data, preparation of inspection reports with respect to statistical aspects of the inspection, and the distribution of inspection samples to more than one analytical laboratory. Volume 3 covers generally the same material as Volumes 1 and 2 but with much greater unity and cohesiveness. Further, the cook-book style of the previous two volumes has been replaced by one that makes use of equations and formulas as opposed to computational steps, and that also provides the bases for the statistical procedures discussed. Hopefully, this will help minimize the frequency of misapplications of the techniques

  2. Procedure manual for the estimation of average indoor radon-daughter concentrations using the radon grab-sampling method

    International Nuclear Information System (INIS)

    George, J.L.

    1986-04-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center to provide standardization, calibration, comparability, verification of data, quality assurance, and cost-effectiveness for the measurement requirements of DOE remedial action programs. One of the remedial-action measurement needs is the estimation of average indoor radon-daughter concentration. One method for accomplishing such estimations in support of DOE remedial action programs is the radon grab-sampling method. This manual describes procedures for radon grab sampling, with the application specifically directed to the estimation of average indoor radon-daughter concentration (RDC) in highly ventilated structures. This particular application of the measurement method is for cases where RDC estimates derived from long-term integrated measurements under occupied conditions are below the standard and where the structure being evaluated is considered to be highly ventilated. The radon grab-sampling method requires that sampling be conducted under standard maximized conditions. Briefly, the procedure for radon grab sampling involves the following steps: selection of sampling and counting equipment; sample acquisition and processing, including data reduction; calibration of equipment, including provisions to correct for pressure effects when sampling at various elevations; and incorporation of quality-control and assurance measures. This manual describes each of the above steps in detail and presents an example of a step-by-step radon grab-sampling procedure using a scintillation cell

  3. A comparison between the conventional manual ROI method and an automatic algorithm for semiquantitative analysis of SPECT studies

    International Nuclear Information System (INIS)

    Pagan, L; Novi, B; Guidarelli, G; Tranfaglia, C; Galli, S; Lucchi, G; Fagioli, G

    2011-01-01

    In this study, the performance of a free software for automatic segmentation of striatal SPECT brain studies (BasGanV2 - www.aimn.it) and a standard manual Region Of Interest (ROI) method were compared. The anthropomorphic Alderson RSD phantom, filled with solutions at different concentration of 123 I-FP-CIT with Caudate-Putamen to Background ratios between 1 and 8.7 and Caudate to Putamen ratios between 1 and 2, was imaged on a Philips-Irix triple head gamma camera. Images were reconstructed using filtered back-projection and processed with both BasGanV2, that provides normalized striatal uptake values on volumetric anatomical ROIs, and a manual method, based on average counts per voxel in ROIs drawn in a three-slice section. Caudate-Putamen/Background and Caudate/Putamen ratios obtained with the two methods were compared with true experimental ratios. Good correlation was found for each method; BasGanV2, however, has higher R index (BasGan R mean = 0.95, p mean = 0.89, p 123 I-FP-CIT SPECT data with, moreover, the advantage of the availability of a control subject's database.

  4. Inspection technologies -Development of national safeguards technology-

    International Nuclear Information System (INIS)

    Hong, J. S.; Kim, B. K.; Kwack, E. H.

    1996-12-01

    17 facility regulations prepared by nuclear facilities according to the Ministerial Notices were evaluated. Safeguards inspection activities under Safeguards are described. Safeguards inspection equipments and operation manuals to be used for national inspection are also described. Safeguards report are produced and submitted to MOST by using the computerized nuclear material accounting system at state level. National inspection support system are developed to produce the on-site information for domestic inspection. Planning and establishment of policy for nuclear control of nuclear materials, international cooperation for nuclear control, CTBT, strengthening of international safeguards system, and the supply of PWRs to North Korea are also described. (author). 43 tabs., 39 figs

  5. Current state and development trends of inspections of steam generator tubes by eddy currents method

    International Nuclear Information System (INIS)

    Kubis, S.; Herman, M.

    1988-01-01

    The requirements are presented for steam generator tube testing and the factors are discussed affecting the accuracy of measurement by the eddy currents method. The individual types of the eddy currents method are described, such as the single-frequency method, the multi-frequency method and the pulse eddy currents method. The demands are summed up on manipulator systems whose design is adapted to the steam generator configuration conditions. (E.S.). 5 figs., 16 possu

  6. Inspection vehicle

    International Nuclear Information System (INIS)

    Takahashi, Masaki; Omote, Tatsuyuki; Yoneya, Yutaka; Tanaka, Keiji; Waki, Tetsuro; Yoshida, Tomiji; Kido, Tsuyoshi.

    1993-01-01

    An inspection vehicle comprises a small-sized battery directly connected with a power motor or a direct power source from trolly lines and a switching circuit operated by external signals. The switch judges advance or retreat by two kinds of signals and the inspection vehicle is recovered by self-running. In order to recover the abnormally stopped inspection vehicle to the targeted place, the inspection vehicle is made in a free-running state by using a clutch mechanism and is pushed by an other vehicle. (T.M.)

  7. Quantitative Risk Assessment of Patient Manual Handling in Wards of One of the Hospitals of Tehran using MAPO Method, Iran

    Directory of Open Access Journals (Sweden)

    Sajad Ataei

    2017-05-01

    Full Text Available Background and Objectives: Manual handling of disabled patients is one of the important and effective factors in acute low back pain among exposed nurses. The present study was conducted with the objective of quantitative risk assessment of patient manual handling among nurses in wards of one of the hospitals in Tehran using MAPO method. Methods: The present study was conducted as an analytical-cross-sectional study in 26 wards of one of the hospitals in Tehran city. Samples were selected by census method from nurses and paramedics of different wards of hospital. Data collection was performed using demographic information and MAPO checklist. Results: The highest score of MAPO were, respectively, related to wards of DI clinic (score, 14.7, men orthopedic (score, 6.3, and general operating room (score, 57. 53.8% of hospital wards were at the level 2 corrective action, which indicated that the risk of musculoskeletal disorder is 2.4 times higher than level 1 corrective action. Conclusion: Given that the proportion of disabled patient in cooperation and/or partial cooperation, lifting tools, auxiliary, wheelchair, and training have the most role among risk factors for above-mentioned wards, increasing the number of human resources and wheelchair, use of lifting and auxiliary tools and training reduce MAPO score and consequently the risk of musculoskeletal disorders.

  8. VLE measurements using a static cell vapor phase manual sampling method accompanied with an empirical data consistency test

    International Nuclear Information System (INIS)

    Freitag, Joerg; Kosuge, Hitoshi; Schmelzer, Juergen P.; Kato, Satoru

    2015-01-01

    Highlights: • We use a new, simple static cell vapor phase manual sampling method (SCVMS) for VLE (x, y, T) measurement. • The method is applied to non-azeotropic, asymmetric and two-liquid phase forming azeotropic binaries. • The method is approved by a data consistency test, i.e., a plot of the polarity exclusion factor vs. pressure. • The consistency test reveals that with the new SCVMS method accurate VLE near ambient temperature can be measured. • Moreover, the consistency test approves that the effect of air in the SCVMS system is negligible. - Abstract: A new static cell vapor phase manual sampling (SCVMS) method is used for the simple measurement of constant temperature x, y (vapor + liquid) equilibria (VLE). The method was applied to the VLE measurements of the (methanol + water) binary at T/K = (283.2, 298.2, 308.2 and 322.9), asymmetric (acetone + 1-butanol) binary at T/K = (283.2, 295.2, 308.2 and 324.2) and two-liquid phase forming azeotropic (water + 1-butanol) binary at T/K = (283.2 and 298.2). The accuracy of the experimental data was approved by a data consistency test, that is, an empirical plot of the polarity exclusion factor, β, vs. the system pressure, P. The SCVMS data are accurate, because the VLE data converge to the same lnβ vs. lnP straight line determined from conventional distillation-still method and a headspace gas chromatography method

  9. Light and current induced degradation in p-type multi-crystalline cells and development of an inspection method and a stabilization method

    Energy Technology Data Exchange (ETDEWEB)

    Broek, K.M.; Bennett, I.J.; Jansen, M.J.; Borg, Van der N.J.C.M.; Eerenstein, W. [ECN Solar Energy, Petten (Netherlands)

    2012-09-15

    Stable solar cells are needed for durability testing of different combinations of module materials. In such a test, significant power losses in full-size modules with multi-crystalline cells after thermal cycling have been observed. This has been related to degradation of the solar cells used and it appeared that this was caused by current induced degradation. This phenomenon is not limited to boron doped Cz-Si, but can also occur in p-type multi-crystalline silicon. Work was done to develop an incoming inspection method for new batches of cells. Also, stabilisation procedures for modules containing cells that are sensitive to degradation have been determined.

  10. Probes for inspections of heat exchanges installed at nuclear power plants type PWR by eddy current method

    International Nuclear Information System (INIS)

    Silva, Alonso F.O.

    2007-01-01

    From all non destructive examination methods usable to perform integrity evaluation of critical equipment installed at nuclear power plants (NPP), eddy current test (ET) may be considered the most important one, when examining heat exchangers. For its application, special probes and reference calibration standards are employed. In pressurized water reactor (PWR) NPPs, a particularly critical equipment is the steam generator (SG), a huge heat exchanger that contains thousands of U-bend thin wall tubes. Due to its severe working conditions (pressure and temperature), that component is periodically examined by means of ET. In this paper a revision of the operating fundamentals of the main ET probes, used to perform SG inspections is presented. (author)

  11. FMEA of manual and automated methods for commissioning a radiotherapy treatment planning system.

    Science.gov (United States)

    Wexler, Amy; Gu, Bruce; Goddu, Sreekrishna; Mutic, Maya; Yaddanapudi, Sridhar; Olsen, Lindsey; Harry, Taylor; Noel, Camille; Pawlicki, Todd; Mutic, Sasa; Cai, Bin

    2017-09-01

    To evaluate the level of risk involved in treatment planning system (TPS) commissioning using a manual test procedure, and to compare the associated process-based risk to that of an automated commissioning process (ACP) by performing an in-depth failure modes and effects analysis (FMEA). The authors collaborated to determine the potential failure modes of the TPS commissioning process using (a) approaches involving manual data measurement, modeling, and validation tests and (b) an automated process utilizing application programming interface (API) scripting, preloaded, and premodeled standard radiation beam data, digital heterogeneous phantom, and an automated commissioning test suite (ACTS). The severity (S), occurrence (O), and detectability (D) were scored for each failure mode and the risk priority numbers (RPN) were derived based on TG-100 scale. Failure modes were then analyzed and ranked based on RPN. The total number of failure modes, RPN scores and the top 10 failure modes with highest risk were described and cross-compared between the two approaches. RPN reduction analysis is also presented and used as another quantifiable metric to evaluate the proposed approach. The FMEA of a MTP resulted in 47 failure modes with an RPN ave of 161 and S ave of 6.7. The highest risk process of "Measurement Equipment Selection" resulted in an RPN max of 640. The FMEA of an ACP resulted in 36 failure modes with an RPN ave of 73 and S ave of 6.7. The highest risk process of "EPID Calibration" resulted in an RPN max of 576. An FMEA of treatment planning commissioning tests using automation and standardization via API scripting, preloaded, and pre-modeled standard beam data, and digital phantoms suggests that errors and risks may be reduced through the use of an ACP. © 2017 American Association of Physicists in Medicine.

  12. T-3 cask users' manual. Revision 1

    International Nuclear Information System (INIS)

    1986-06-01

    This user's manual for the T-C spent fuel cask provides information on: operating procedures; inspection and maintenance procedures; criticality evaluation; shielding evaluation; thermal evaluation; structural evaluation; and limitations

  13. Inspector's manual for mechanically stabilized earth walls.

    Science.gov (United States)

    2010-06-01

    The scope of the project is to develop a condition rating system, creation of an inspector's manual to reference during : inspection or address any training for inspectors at the district level. The research project will develop a MSE wall : conditio...

  14. CSTEM User Manual

    Science.gov (United States)

    Hartle, M.; McKnight, R. L.

    2000-01-01

    This manual is a combination of a user manual, theory manual, and programmer manual. The reader is assumed to have some previous exposure to the finite element method. This manual is written with the idea that the CSTEM (Coupled Structural Thermal Electromagnetic-Computer Code) user needs to have a basic understanding of what the code is actually doing in order to properly use the code. For that reason, the underlying theory and methods used in the code are described to a basic level of detail. The manual gives an overview of the CSTEM code: how the code came into existence, a basic description of what the code does, and the order in which it happens (a flowchart). Appendices provide a listing and very brief description of every file used by the CSTEM code, including the type of file it is, what routine regularly accesses the file, and what routine opens the file, as well as special features included in CSTEM.

  15. Assessing symmetry using the mirror stand device with manual and software-assisted methods in postoperative zygomatic fracture patients

    Science.gov (United States)

    Syarif, A. N.; Bangun, K.

    2017-08-01

    Zygomatic fractures are among the most common fractures to the facial skeleton. However, because no standard and reliable method of evaluation is available to assess postoperative patients, we often rely on photographs and subjective assessments. A portable mirror stand device (MiRS), which is a new method for the standardization of photography, was developed in our institution. Used with image analysis software, this device provides a new method for evaluating outcomes after the open reduction and internal fixation of zygomatic fractures. The portable mirror stand device was set up in our outpatient clinic at the Cleft Craniofacial Center at Cipto Mangunkusumo Hospital. Photographs of 11 postoperative patients were taken using the device, and they were analyzed both manually and using image analysis software (ImageJ 1.46) for symmetry. The two methods were then compared to assess the correlation and agreement of the results. The measurements taken using the manual method and the software-assisted method did not differ significantly, which indicated the good agreement between the two methods. The results of the symmetry achieved atour center were similar to other centers in the Asian region (ΔZy = 3.4±1.5 mm, ΔBc = 2.6±1.6 mm, ΔCh = 2.3±2.4 mm) compared with (ΔZy = 3.2±1.7 mm, ΔBc = 2.6±1.6 mm, ΔCh = 2.3±2.5 mm). The treatment of zygomatic fracture a tour center achieved good results. The portable mirror stand device assisted the image analysis software (ImageJ 1.46), which could be beneficial in assessing symmetry in postoperative zygomatic fracture patients.

  16. A pilot application of risk-based methods to establish in-service inspection priorities for nuclear components at Surry Unit 1 Nuclear Power Station

    International Nuclear Information System (INIS)

    Vo, T.; Gore, B.; Simonen, F.; Doctor, S.

    1994-08-01

    As part of the Nondestructive Evaluation Reliability Program sponsored by the US Nuclear Regulatory Commission, the Pacific Northwest Laboratory is developing a method that uses risk-based approaches to establish in-service inspection plans for nuclear power plant components. This method uses probabilistic risk assessment (PRA) results and Failure Modes and Effects Analysis (FEMA) techniques to identify and prioritize the most risk-important systems and components for inspection. The Surry Nuclear Power Station Unit 1 was selected for pilot applications of this method. The specific systems addressed in this report are the reactor pressure vessel, the reactor coolant, the low-pressure injection, and the auxiliary feedwater. The results provide a risk-based ranking of components within these systems and relate the target risk to target failure probability values for individual components. These results will be used to guide the development of improved inspection plans for nuclear power plants. To develop inspection plans, the acceptable level of risk from structural failure for important systems and components will be apportioned as a small fraction (i.e., 5%) of the total PRA-estimated risk for core damage. This process will determine target (acceptable) risk and target failure probability values for individual components. Inspection requirements will be set at levels to assure that acceptable failure probabilistics are maintained

  17. How to Research People's First Impressions of Websites? Eye-Tracking as a Usability Inspection Method and Online Focus Group Research

    Science.gov (United States)

    Herendy, Csilla

    The visual surface of the Hungarian governmental portal - magyarorszag.hu - was inspected in 2007 with two different inspection methods: Eye tacking research and Online focus group research. Both methods help to understand and to chart not only the usability of different websites but also the affective imp ressions associated with the websites. In this study, an Experimental and a Control-group were tested to assess the usability of the site and the emotional re actions to it. The results reveal that the Hungarian government website is too complicated, dull and difficult to apprehend at a glance.

  18. Comparison of the time behavior in the separation of light and heavy materials in X-ray backscattered method as a diagnostic tool in inspection

    International Nuclear Information System (INIS)

    Faezeh, Rahmani; Sepideh Sadat, Azimi; Esmaiel, Bayat; Vahid, Dost Mohammadi

    2016-01-01

    X-ray backscattered method based on Compton backscattering is used in the inspection field. In contrast to transmission method, source and detectors are positioned on one side of the target, so in the situation that transmission inspection is difficult, X-ray backscattered method can be provided suitable data in the inspection field. Also, detection of hidden explosives and narcotic materials are very difficult or impossible in transmission methods. High intensity backscattered beam from light materials (low-Z), such as explosives and narcotics, in comparison to the heavy materials (high-Z), made this method as the strong technique in inspection. X-ray and gamma photons scattered by the light material (such as PE and PTFE) as well as heavy material (such as Fe and Cu) were studied using MCNPX2.6 Monte Carlo code. The results showed that rise time of pulse from light materials are slower than that of from heavy materials due to multi scattering of low energy photons in the light ones, so time expansion would occur in signals from light elements. If measurement is possible, the difference in time behavior can be used as a novel method in complementary diagnostic tool beside the use of pulse height in X-ray backscattered method.

  19. Knowledge-based inspection:modelling complex processes with the integrated Safeguards Modelling Method (iSMM)

    International Nuclear Information System (INIS)

    Abazi, F.

    2011-01-01

    Increased level of complexity in almost every discipline and operation today raises the demand for knowledge in order to successfully run an organization whether to generate profit or to attain a non-profit mission. Traditional way of transferring knowledge to information systems rich in data structures and complex algorithms continue to hinder the ability to swiftly turnover concepts into operations. Diagrammatic modelling commonly applied in engineering in order to represent concepts or reality remains to be an excellent way of converging knowledge from domain experts. The nuclear verification domain represents ever more a matter which has great importance to the World safety and security. Demand for knowledge about nuclear processes and verification activities used to offset potential misuse of nuclear technology will intensify with the growth of the subject technology. This Doctoral thesis contributes with a model-based approach for representing complex process such as nuclear inspections. The work presented contributes to other domains characterized with knowledge intensive and complex processes. Based on characteristics of a complex process a conceptual framework was established as the theoretical basis for creating a number of modelling languages to represent the domain. The integrated Safeguards Modelling Method (iSMM) is formalized through an integrated meta-model. The diagrammatic modelling languages represent the verification domain and relevant nuclear verification aspects. Such a meta-model conceptualizes the relation between practices of process management, knowledge management and domain specific verification principles. This fusion is considered as necessary in order to create quality processes. The study also extends the formalization achieved through a meta-model by contributing with a formalization language based on Pattern Theory. Through the use of graphical and mathematical constructs of the theory, process structures are formalized enhancing

  20. Image combination enhancement method for X-ray compton back-scattering security inspection body scanner

    International Nuclear Information System (INIS)

    Wang Huaiying; Zhang Yujin; Yang Lirui; Li Dong

    2011-01-01

    As for X-ray Compton Back-Scattering (CBS) body scanner, image clearness is very important for the performance of detecting the contraband hidden on the body. A new image combination enhancement method is provided based on characteristics of CBS body images and points of human vision. After processed by this method, the CBS image will be obviously improved with clear levels, distinct outline and uniform background. (authors)

  1. MUSIC imaging method for electromagnetic inspection of composite multi-layers

    Science.gov (United States)

    Rodeghiero, Giacomo; Ding, Ping-Ping; Zhong, Yu; Lambert, Marc; Lesselier, Dominique

    2015-03-01

    A first-order asymptotic formulation of the electric field scattered by a small inclusion (with respect to the wavelength in dielectric regime or to the skin depth in conductive regime) embedded in composite material is given. It is validated by comparison with results obtained using a Method of Moments (MoM). A non-iterative MUltiple SIgnal Classification (MUSIC) imaging method is utilized in the same configuration to locate the position of small defects. The effectiveness of the imaging algorithm is illustrated through some numerical examples.

  2. A DOE manual: DOE Methods for Evaluating Environmental and Waste Management Samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Riley, R.G.

    1994-01-01

    Waste Management inherently requires knowledge of the waste's chemical composition. The waste can often be analyzed by established methods; however, if the samples are radioactive, or are plagued by other complications, established methods may not be feasible. The US Department of Energy (DOE) has been faced with managing some waste types that are not amenable to standard or available methods, so new or modified sampling and analysis methods are required. These methods are incorporated into DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods), which is a guidance/methods document for sampling and analysis activities in support of DOE sites. It is a document generated by consensus of the DOE laboratory staff and is intended to fill the gap within existing guidance documents (e. g., the Environmental Protection Agency's (EPA's) Test Methods for Evaluating Solid Waste, SW-846), which apply to low-level or non-radioactive samples. DOE Methods fills the gap by including methods that take into account the complexities of DOE site matrices. The most recent update, distributed in October 1993, contained quality assurance (QA), quality control (QC), safety, sampling, organic analysis, inorganic analysis, and radioanalytical guidance as well as 29 methods. The next update, which will be distributed in April 1994, will contain 40 methods and will therefore have greater applicability. All new methods are either peer reviewed or labeled ''draft'' methods. Draft methods were added to speed the release of methods to field personnel

  3. NEW METHOD FOR ACTIVE SURFACES QUALITY INSPECTION FOR HIGH DIMENSIONS BEARINGS

    Directory of Open Access Journals (Sweden)

    BRAUN Barbu

    2016-07-01

    Full Text Available The paper presents a stage of an ample research on high quality control for different type of large dimension bearings, with application in wind turbines for electrical energy production. There is presented a new and efficient method for bearing’s active surfaces quality control, in terms of roughness, to ensure a good and safety functioning and a long life of these. The research involved the use of a powerful digital microscope for surface analysis followed by an assisted by PC algorithm for results obtaining in terms of roughness values. It has been observed that the proposed analyzing method could in the future to be successfully applied for a very large range of bearings, different dimensions and applications.

  4. Adaptive ultrasonic imaging with the total focusing method for inspection of complex components immersed in water

    Science.gov (United States)

    Le Jeune, L.; Robert, S.; Dumas, P.; Membre, A.; Prada, C.

    2015-03-01

    In this paper, we propose an ultrasonic adaptive imaging method based on the phased-array technology and the synthetic focusing algorithm Total Focusing Method (TFM). The general principle is to image the surface by applying the TFM algorithm in a semi-infinite water medium. Then, the reconstructed surface is taken into account to make a second TFM image inside the component. In the surface reconstruction step, the TFM algorithm has been optimized to decrease computation time and to limit noise in water. In the second step, the ultrasonic paths through the reconstructed surface are calculated by the Fermat's principle and an iterative algorithm, and the classical TFM is applied to obtain an image inside the component. This paper presents several results of TFM imaging in components of different geometries, and a result obtained with a new technology of probes equipped with a flexible wedge filled with water (manufactured by Imasonic).

  5. Computer-aided ultrasonic inspection of steam turbine rotors

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, K.H.; Weber, M.; Weiss, M. [GEC ALSTHOM Energie GmbH, Nuremberg (Germany)

    1998-12-31

    As the output and economic value of power plants increase, the detection and sizing of the type of flaws liable to occur in the rotors of turbines using ultrasonic methods assumes increasing importance. An ultrasonic inspection carried out at considerable expense is expected to bring to light all safety-relevant flaws and to enable their size to be determined so as to permit a fracture-mechanics analysis to assess the reliability of the rotor under all possible stresses arising in operation with a high degree of accuracy. The advanced computer-aided ultrasonic inspection of steam turbine rotors have improved reliability, accuracy and reproducibility of ultrasonic inspection. Further, there has been an improvement in the resolution of resolvable group indications by applying reconstruction and imagine methods. In general, it is also true for the advanced computer-aided ultrasonic inspection methods that, in the case of flaw-affected forgings, automated data acquisition provides a substantial rationalization and a significant documentation of the results for the fracture mechanics assessment compared to manual inspection. (orig.) 8 refs.

  6. Computer-aided ultrasonic inspection of steam turbine rotors

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, K H; Weber, M; Weiss, M [GEC ALSTHOM Energie GmbH, Nuremberg (Germany)

    1999-12-31

    As the output and economic value of power plants increase, the detection and sizing of the type of flaws liable to occur in the rotors of turbines using ultrasonic methods assumes increasing importance. An ultrasonic inspection carried out at considerable expense is expected to bring to light all safety-relevant flaws and to enable their size to be determined so as to permit a fracture-mechanics analysis to assess the reliability of the rotor under all possible stresses arising in operation with a high degree of accuracy. The advanced computer-aided ultrasonic inspection of steam turbine rotors have improved reliability, accuracy and reproducibility of ultrasonic inspection. Further, there has been an improvement in the resolution of resolvable group indications by applying reconstruction and imagine methods. In general, it is also true for the advanced computer-aided ultrasonic inspection methods that, in the case of flaw-affected forgings, automated data acquisition provides a substantial rationalization and a significant documentation of the results for the fracture mechanics assessment compared to manual inspection. (orig.) 8 refs.

  7. PNNL Hoisting and Rigging Manual

    Energy Technology Data Exchange (ETDEWEB)

    Haynie, Todd O.; Fullmer, Michael W.

    2008-12-29

    This manual describes the safe and cost effective operation, inspection, maintenance, and repair requirements for cranes, hoists, fork trucks, slings, rigging hardware, and hoisting equipment. It is intended to be a user's guide to requirements, codes, laws, regulations, standards, and practices that apply to Pacific Northwest National Laboratory (PNNL) and its subcontractors.

  8. DIAGNOSTIC CARDIAC CATHETERIZATION USING THE MEDRAD AVANTA FLUID MANAGEMENT SYSTEM AS COMPARED TO THE TRADITIONAL MANUAL INJECTION METHOD

    Energy Technology Data Exchange (ETDEWEB)

    Winniford, Michael D

    2013-02-08

    Nearly 4 million patient procedures performed annually in US cardiac catheterization laboratories utilize contrast media to achieve vessel opacification. The amount of contrast media used is variable and depends on the complexity of the procedure, the method of contrast delivery as well as the skill-level of the operator. Since the total amount of contrast used for each procedure can have both patient safety and economic implications, it is essential for cardiologists to have the ability to control contrast delivery such that optimal angiographic image quality is achieved using the least amount of contrast. Although the complication rate associated with cardiac catheterization remains low, the most common serious complication, contrast-induced nephropathy (CIN), is associated with poor prognosis and a high mortality rate. Numerous interventional strategies for preventing and reducing the severity of CIN have demonstrated varying degrees of clinical benefit, but none has been shown to reliably prevent this serious complication. To date, the most effective approach for reducing the risk of CIN is to properly hydrate the patient and to minimize the amount of contrast media administered. Automated injection systems are intended for use in virtually all cardiac catheterization procedures and have numerous features which can provide potential advantages over traditional methods. With automated injection technology the operator is able to control and precisely monitor contrast delivery. Additionally, the MEDRAD Avanta Fluid Management Injection System utilizes a sterile contrast reservoir which eliminates the need to discard unused contrast in individual opened containers following each procedure. Considering that an average of 50% of opened contrast media is wasted using manual injection methods, this savings can provide a substantial economic benefit. Automated systems also facilitate the use of smaller (5 French) catheter sizes. Precise flow control and the use of

  9. Hospital Inspections

    Data.gov (United States)

    U.S. Department of Health & Human Services — Welcome to hospitalinspections.org, a website run by the Association of Health Care Journalists (AHCJ) that aims to make federal hospital inspection reports easier...

  10. Inspection method of optical fiber preforms by x-ray absorption measurements

    International Nuclear Information System (INIS)

    Takahashi, H.; Nakamura, K.; Shibuya, S.; Kuroha, T.

    1980-01-01

    A method for measuring the refractive index distribution of optical fiber preforms has been developed by application of the theory of X-ray radiography. The composition of quartz optical fiber materials is, in most cases, limited to the group of five elements - Ge, P, Si, O and B. Of them, Ge is an essential element to determine the structure of refractive index of an optical fiber and the distribution of its density can be regarded approximately as the distribution of refractive index. On the other hand, the coefficient of low-energy X-ray absorption by the elements depends markedly on their atomic numbers, and Ge has a far larger absorption coefficient than the other four elements. Therefore, analysis of the intensity of X-ray absorbed by optical fiber preforms makes it possible to determine the distribution of Ge density and consequently the distribution of refractive index. (author)

  11. Use of isotope and radiation methods in soil and water management and crop nutrition. Manual

    International Nuclear Information System (INIS)

    2001-01-01

    This publication is a replacement for the IAEA Training Course Series No. 2 'Use of Nuclear Techniques in Studies of Soil-Plant Relationships' published in 1990. This edition, prepared by staff of the Soil Science Unit, Seibersdorf, and the Soil and Water Management and Crop Nutrition Section, Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture, Vienna, differs in many respects from its predecessor both in terms of content and objectives. The earlier publication provided basic information for use in interregional training courses held at regular intervals at the Seibersdorf Laboratories. Since the discontinuation of these training courses in 1996, the need for dissemination of up to date information to Member States has become more acute, particularly in view of the evolution of new methodologies during the past decade and new applications of existing methodologies to monitor the dynamics of soil, water and nutrients in cropping systems, and to pilot test interventions to conserve the natural resource base and optimize the availability of water and nutrients to crops. The present publication attempts to fulfill a part of this need. The manual provides an overview of the use of nuclear techniques in soil science and plant nutrition, balancing the need for a comprehensive coverage of a multitude of techniques involving isotopic tracers and sealed or unsealed sources, while giving sufficient depth to be of practical value to the end-users - students, technicians, scientists in national agricultural research systems and fellowship trainees. In this respect it is important to emphasize that nuclear techniques do not in themselves provide solutions to real world problems - they provide tools which when used in conjunction with other techniques, provide precise and specific information necessary to understand system dynamics and hence the value of alternative management practices to improve system productivity and resource conservation. This publication

  12. Use of isotope and radiation methods in soil and water management and crop nutrition. Manual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-12-01

    This publication is a replacement for the IAEA Training Course Series No. 2 'Use of Nuclear Techniques in Studies of Soil-Plant Relationships' published in 1990. This edition, prepared by staff of the Soil Science Unit, Seibersdorf, and the Soil and Water Management and Crop Nutrition Section, Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture, Vienna, differs in many respects from its predecessor both in terms of content and objectives. The earlier publication provided basic information for use in interregional training courses held at regular intervals at the Seibersdorf Laboratories. Since the discontinuation of these training courses in 1996, the need for dissemination of up to date information to Member States has become more acute, particularly in view of the evolution of new methodologies during the past decade and new applications of existing methodologies to monitor the dynamics of soil, water and nutrients in cropping systems, and to pilot test interventions to conserve the natural resource base and optimize the availability of water and nutrients to crops. The present publication attempts to fulfill a part of this need. The manual provides an overview of the use of nuclear techniques in soil science and plant nutrition, balancing the need for a comprehensive coverage of a multitude of techniques involving isotopic tracers and sealed or unsealed sources, while giving sufficient depth to be of practical value to the end-users - students, technicians, scientists in national agricultural research systems and fellowship trainees. In this respect it is important to emphasize that nuclear techniques do not in themselves provide solutions to real world problems - they provide tools which when used in conjunction with other techniques, provide precise and specific information necessary to understand system dynamics and hence the value of alternative management practices to improve system productivity and resource conservation. This publication

  13. Ultrasonic boiler inspection and economic analysis guidelines

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    Boiler tube failures cause approximately 6% availability loss of large fossil-fired power generating plants. This loss can be reduced by systematic approaches using ultrasonic examination and root cause failure analysis methods. Two projects sponsored by EPRI have provided utility engineers with guidelines for performing ultrasonic examinations and with details on 22 types of tube failure mechanisms. A manual has been published that provides descriptions of typical locations, superficial appearances, damage mechanisms, metallurgy, microstructural changes, likely root causes, and potential corrective actions. Application of the principles in the manual is being demonstrated in an EPRI-funded project at 10 electric utilities over the next two years. Guidelines have been published that prescribe the activities necessary for ultrasonic examinations of boiler tubes. Eight essential elements of a boiler examination should be performed to assure that possible economic benefits are obtained. Work was supported by EPRI under RP 1890 and RP 1865. A software package has been developed for effectively planning inspections for wall thinning in fossil-fired boiler tubing. The software assists in minimizing costs associated with maintenance, such as inspection and repair, while the life of the boiler is maximized

  14. Eddy current manual: v.1

    International Nuclear Information System (INIS)

    Cecco, V.S.; Van Drunen, G.; Sharp, F.L.

    1983-09-01

    This training and reference manual was assembled to provide those involved in eddy current testing with both the fundamental principles of the technique as well as the knowledge to deal with often complicated test results. A non-rigorous approach is used to simplify complex physical phenomena. Emphasis is placed on proper choice of test frequency and signal interpretation. Defect detection and diagnosis receive particular attention. Design and construction of probes are covered extensively since probes play a key role in eddy current testing. The advantages and limitations of various probe types are discussed. Electromagnetic theory, instrumentation, test methods and signal analysis are covered. Simplified derivations of probe response to test parameters are presented to develop a basic understanding of eddy current behaviour. Eddy current signals are presented on impedance plane diagrams throughout the manual since this is the most common display on modern, general purpose instruments. The use of Σphase lagΣ in signal analysis is covered in detail. To supplement theory, practical examples are presented to develop proficiency in performing inspections, and to illustrate how basic principles are applied to diagnose real signals

  15. Estimation of inspection effort

    International Nuclear Information System (INIS)

    Mullen, M.F.; Wincek, M.A.

    1979-06-01

    An overview of IAEA inspection activities is presented, and the problem of evaluating the effectiveness of an inspection is discussed. Two models are described - an effort model and an effectiveness model. The effort model breaks the IAEA's inspection effort into components; the amount of effort required for each component is estimated; and the total effort is determined by summing the effort for each component. The effectiveness model quantifies the effectiveness of inspections in terms of probabilities of detection and quantities of material to be detected, if diverted over a specific period. The method is applied to a 200 metric ton per year low-enriched uranium fuel fabrication facility. A description of the model plant is presented, a safeguards approach is outlined, and sampling plans are calculated. The required inspection effort is estimated and the results are compared to IAEA estimates. Some other applications of the method are discussed briefly. Examples are presented which demonstrate how the method might be useful in formulating guidelines for inspection planning and in establishing technical criteria for safeguards implementation

  16. Accident Analysis and Barrier Function (AEB) Method. Manual for Incident Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Svenson, Ola [Stockholm Univ. (Sweden). Dept. of Psychology

    2000-02-01

    The Accident Analysis and Barrier Function (AEB) Method models an accident or incident as a series of interactions between human and technical systems. In the sequence of human and technical errors leading to an accident there is, in principle, a possibility to arrest the development between each two successive errors. This can be done by a barrier function which, for example, can stop an operator from making an error. A barrier function can be performed by one or several barrier function systems. To illustrate, a mechanical system, a computer system or another operator can all perform a given barrier function to stop an operator from making an error. The barrier function analysis consists of analysis of suggested improvements, the effectiveness of the improvements, the costs of implementation, probability of implementation, the cost of maintaining the barrier function, the probability that maintenance will be kept up to standards and the generalizability of the suggested improvement. The AEB method is similar to the US method called HPES, but differs from that method in different ways. To exemplify, the AEB method has more emphasis on technical errors than HPES. In contrast to HPES that describes a series of events, the AEB method models only errors. This gives a more focused analysis making it well suited for checking other HPES-type accident analyses. However, the AEB method is a generic and stand-alone method that has been applied in other fields than nuclear power, such as, in traffic accident analyses.

  17. Accident Analysis and Barrier Function (AEB) Method. Manual for Incident Analysis

    International Nuclear Information System (INIS)

    Svenson, Ola

    2000-02-01

    The Accident Analysis and Barrier Function (AEB) Method models an accident or incident as a series of interactions between human and technical systems. In the sequence of human and technical errors leading to an accident there is, in principle, a possibility to arrest the development between each two successive errors. This can be done by a barrier function which, for example, can stop an operator from making an error. A barrier function can be performed by one or several barrier function systems. To illustrate, a mechanical system, a computer system or another operator can all perform a given barrier function to stop an operator from making an error. The barrier function analysis consists of analysis of suggested improvements, the effectiveness of the improvements, the costs of implementation, probability of implementation, the cost of maintaining the barrier function, the probability that maintenance will be kept up to standards and the generalizability of the suggested improvement. The AEB method is similar to the US method called HPES, but differs from that method in different ways. To exemplify, the AEB method has more emphasis on technical errors than HPES. In contrast to HPES that describes a series of events, the AEB method models only errors. This gives a more focused analysis making it well suited for checking other HPES-type accident analyses. However, the AEB method is a generic and stand-alone method that has been applied in other fields than nuclear power, such as, in traffic accident analyses

  18. Production of a manual on testing methods for the use of bamboo in engineering applications

    NARCIS (Netherlands)

    Janssen, J.J.A.; Kumar, Arun; Ramanuja Rao, I.V.; Sastry, Cherla

    1998-01-01

    Tests on different properties of bamboo are being conducted in many laboratories in bamboo-growing countries. In the absence of standards that prescribe definite methods, the laboratory staff often has to improvise and innovate to find clever methods or tools. In many cases, such useful information

  19. Methods of In-Process On-Machine Auto-Inspection of Dimensional Error and Auto-Compensation of Tool Wear for Precision Turning

    Directory of Open Access Journals (Sweden)

    Shih-Ming Wang

    2016-04-01

    Full Text Available The purpose of this study is mainly to develop an information and communication technology (ICT-based intelligent dimension inspection and tool wear compensation method for precision tuning. With the use of vibration signal processing/characteristics analysis technology combined with ICT, statistical analysis, and diagnosis algorithms, the method can be used to proceed with an on-line dimension inspection and on-machine tool wear auto-compensation for the turning process. Meanwhile, the method can also monitor critical tool life to identify the appropriate time for cutter replacement to reduce machining costs and improve the production efficiency of the turning process. Compared to the traditional ways, the method offers the advantages of requiring less manpower, and having better production efficiency, high tool life, fewer scrap parts, and low costs for inspection instruments. Algorithms and diagnosis threshold values for the detection, cutter wear compensation, and cutter life monitoring were developed. In addition, a bilateral communication module utilizing FANUC Open CNC (computer numerical control Application Programming Interface (API Spec was developed for the on-line extraction of instant NC (numerical control codes for monitoring and transmit commands to CNC controllers for cutter wear compensation. With use of local area networks (LAN to deliver the detection and correction information, the proposed method was able to remotely control the on-machine monitoring process and upload the machining and inspection data to a remote central platform for further production optimization. The verification experiments were conducted on a turning production line. The results showed that the system provided 93% correction for size inspection and 100% correction for cutter wear compensation.

  20. Manual Therapy

    OpenAIRE

    Hakgüder, Aral; Kokino, Siranuş

    2002-01-01

    Manual therapy has been used in the treatment of pain and dysfunction of spinal and peripheral joints for more than a hundred years. Manual medicine includes manipulation, mobilization, and postisometric relaxation techniques. The aim of manual therapy is to enhance restricted movement caused by blockage of joints keeping postural balance, restore function and maintain optimal body mechanics. Anatomic, biomechanical, and neurophysiological evaluations of the leucomotor system is essential for...

  1. Principle features of metal magnetic memory method and inspection tools as compared to known magnetic NDT methods

    International Nuclear Information System (INIS)

    Dubov, A.

    2006-01-01

    Principle features of method of metal magnetic memory (MMM) as compared to known magnetic NDT methods are considered. Among the basic features of the MMM method, that it is based on use of the own magnetic leakage field (SMLF), arising in ferromagnetic and paramagnetic products on accumulations of high-density dislocations. Magnetodislocation hysteresis underlying effect of metal magnetic memory, takes place as at manufacture of products during formation of internal stresses and at their operation under action of working loads. It is impossible to obtain an information source like a self-magnetic field at any conditions with artificial magnetization in working constructions. Such information is formed and can be obtained only in a small external field, as the Earth's magnetic field is, in loaded constructions when deformation energy is a cut above the energy of the external magnetic field. Features and uniqueness of magnetometric instruments are considered. The instruments have no world analogues. Opportunities of the MMM method for the solution of actual NDT problems are: 100% quality control of machine-building products and heterogeneity of metal structure in a line production; express quality control of welded joints in the united complex system of the factors 'structural-mechanical heterogeneity - defects of a weld - structural and technological stress concentrator'; and, early diagnostics of fatigue damages of metal at an estimation and forecasting of equipment lifetime. (author)

  2. Manual of methods for use in the South African Marine Pollution Monitoring Programme

    CSIR Research Space (South Africa)

    Watling, RJ

    1981-07-01

    Full Text Available Methods used in the South African Marine Pollution Monitoring Programme for the analysis of toxic metals, nutrients, oxygen absorbed, chlorophyll, pesticides and bacteria are described. Sample types include biological material, sediments, estuarine...

  3. Manual versus automatic bladder wall thickness measurements: a method comparison study

    NARCIS (Netherlands)

    Oelke, M.; Mamoulakis, C.; Ubbink, D.T.; de la Rosette, J.J.; Wijkstra, H.

    2009-01-01

    Purpose To compare repeatability and agreement of conventional ultrasound bladder wall thickness (BWT) measurements with automatically obtained BWT measurements by the BVM 6500 device. Methods Adult patients with lower urinary tract symptoms, urinary incontinence, or postvoid residual urine were

  4. [Accuracy, precision and speed of parenteral nutrition admixture bags manufacturing: comparison between automated and manual methods].

    Science.gov (United States)

    Zegbeh, H; Pirot, F; Quessada, T; Durand, T; Vételé, F; Rose, A; Bréant, V; Aulagner, G

    2011-01-01

    The parenteral nutrition admixture (PNA) manufacturing in hospital pharmacy is realized by aseptic transfer (AT) or sterilizing filtration (SF). The development of filling systems for PNA manufacturing requires, without standard, an evaluation comparing to traditional methods of SF. The filling accuracy of automated AT and SF was evaluated by mass and physical-chemistry tests in repeatability conditions (identical composition of PNA; n=five bags) and reproducibility conditions (different composition of PNA; n=57 bags). For each manufacturing method, the filling precision and the average time for PNA bags manufacturing were evaluated starting from an identical composition and volume PNA (n=five trials). Both manufacturing methods did not show significant difference of accuracy. Precision of both methods was lower than limits generally admitted for acceptability of mass and physical-chemistry tests. However, the manufacturing time for SF was superior (five different binary admixtures in five bags) or inferior (one identical binary admixture in five bags) to time recorded for automated AT. We show that serial manufacturing of PNA bags by SF with identical composition is faster than automated AT. Nevertheless, automated AT is faster than SF in variable composition of PNA. The manufacturing method choice will be motivate by the nature (i. e., variable composition or not) of the manufactured bags. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  5. Registration of T2-weighted and diffusion-weighted MR images of the prostate: comparison between manual and landmark-based methods

    Science.gov (United States)

    Peng, Yahui; Jiang, Yulei; Soylu, Fatma N.; Tomek, Mark; Sensakovic, William; Oto, Aytekin

    2012-02-01

    Quantitative analysis of multi-parametric magnetic resonance (MR) images of the prostate, including T2-weighted (T2w) and diffusion-weighted (DW) images, requires accurate image registration. We compared two registration methods between T2w and DW images. We collected pre-operative MR images of 124 prostate cancer patients (68 patients scanned with a GE scanner and 56 with Philips scanners). A landmark-based rigid registration was done based on six prostate landmarks in both T2w and DW images identified by a radiologist. Independently, a researcher manually registered the same images. A radiologist visually evaluated the registration results by using a 5-point ordinal scale of 1 (worst) to 5 (best). The Wilcoxon signed-rank test was used to determine whether the radiologist's ratings of the results of the two registration methods were significantly different. Results demonstrated that both methods were accurate: the average ratings were 4.2, 3.3, and 3.8 for GE, Philips, and all images, respectively, for the landmark-based method; and 4.6, 3.7, and 4.2, respectively, for the manual method. The manual registration results were more accurate than the landmark-based registration results (p < 0.0001 for GE, Philips, and all images). Therefore, the manual method produces more accurate registration between T2w and DW images than the landmark-based method.

  6. Reflector construction by sound path curves - A method of manual reflector evaluation in the field

    International Nuclear Information System (INIS)

    Siciliano, F.; Heumuller, R.

    1985-01-01

    In order to describe the time-of-flight behavior of various reflectors we have set up models and derived from them analytical and graphic approaches to reflector reconstruction. In the course of this work, maximum achievable accuracy and possible simplifications were investigated. The aim of the time-of-flight reconstruction method is to determine the points of a reflector on the basis of a sound path function (sound path as the function of the probe index position). This method can only be used on materials which are isotropic in terms of sound velocity since the method relies on time of flight being converted into sound path. This paper deals only with two-dimensional reconstruction, in other words all statements relate to the plane of incidence. The method is based on the fact that the geometrical location of the points equidistant from a certain probe index position is a circle. If circles with radiuses equal to the associated sound path are drawn for various search unit positions the points of intersection of the circles are the desired reflector points

  7. HASL procedures manual

    International Nuclear Information System (INIS)

    1980-08-01

    Addition and corrections to the following sections of the HASL Procedures Manual are provided: Table of Contents; Bibliography; Fallout Collection Methods; Wet/Dry Fallout Collection; Fluoride in Soil and Sediment; Strontium-90; Natural Series; Alpha Emitters; and Gamma Emitters

  8. Lessons learned from the PISC III study of the influence on human factors on inspection reliability

    International Nuclear Information System (INIS)

    Murgatroyd, R.A.; Worrall, G.M.; Crutzen, S.

    1995-01-01

    Results from the PISC II Programme suggested that differences existed between manual inspectors in terms of their skills, knowledge and working practices which could exert a significant influence on the reliability on an inspection. Therefore, a programme of work on human reliability studies was initiated in the PISC III Programme as Action 7, with the objectives of studying and identifying causes of variability in inspection activities, and identifying some of the factors influencing the reliability of inspection in industrial conditions. It was foreseen that the information from Action 7 would aid in the development of methods for reducing the incidence of human error in inspection activities. This paper gives a brief summary of the programme and describes the lessons learned as a result of the work. A considerably more detailed description of the work is available as a PISC report. 3 refs, 3 figs

  9. In service inspection of pipes based on risk methods; Inspeccion en servicio de tuberias basada en metodos de riesgo

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza G, G.; Viais J, J.; Carmona C, M. [ININ, Centro Nuclear ' Dr. Nabor Carrillo Flores' , Carretera Mexico Toluca, S/N. La Marquesa, Ocoyoacac, Mexico, C. P. 52750 (Mexico)]. e-mail: gmg@nuclear.inin.mx

    2006-07-01

    The politics of the Nuclear Regulatory Commission (by its initials in English NRC) of the United States of America on the use of the Probabilistic Safety Analysis (PSA) in activities of nuclear regulation it foments the use of this analysis technique to improve the decisions making, to reduce the unnecessary work in maintenance aspects, inspection and tests and to improve the regulatory efficiency. The inspection programs in service (ISI by its initials in English) developed by the American Society of Mechanical Engineers (by its initials in English ASME) it has been the one primary mechanism to prove the mechanical equipment in plants of nuclear energy, these programs indeed have been carried out in plants of nuclear energy by more of two decades. Their purpose is to identify the conditions, such as indications of cracks that are precursory of flights and ruptures which violate the integrity principles of the pressure frontier. The inspection in service activities include ultrasonic tests, surface tests and penetrating liquids test, also activities that include the scaffolds construction, removal of insulations and welding polishing. The inspections in service every 18 months during the times outside of service are executed. One of the objectives is to lower the costs of the inspections during the times outside of service and to reduce the exposure to the radiation by part of the personnel during these times out for inspections, while it is increased or it maintains the personnel's safety and the reliability. As part of the methodology a pipe segment is selected for which a fault in any point has the same consequences, being calculated the fault probability of the tube using the dimensions of the segment. In this work the inspection in service methodology is applied based on risk to an aspersion system of low pressure of the Laguna Verde Nucleo electric Central. For this system a reduction in the number of welding to inspect of 103 to only 15 is obtained

  10. A manual for inexpensive methods of analyzing and utilizing remote sensor data

    Science.gov (United States)

    Elifrits, C. D.; Barr, D. J.

    1978-01-01

    Instructions are provided for inexpensive methods of using remote sensor data to assist in the completion of the need to observe the earth's surface. When possible, relative costs were included. Equipment need for analysis of remote sensor data is described, and methods of use of these equipment items are included, as well as advantages and disadvantages of the use of individual items. Interpretation and analysis of stereo photos and the interpretation of typical patterns such as tone and texture, landcover, drainage, and erosional form are described. Similar treatment is given to monoscopic image interpretation, including LANDSAT MSS data. Enhancement techniques are detailed with respect to their application and simple techniques of creating an enhanced data item. Techniques described include additive and subtractive (Diazo processes) color techniques and enlargement of photos or images. Applications of these processes, including mappings of land resources, engineering soils, geology, water resources, environmental conditions, and crops and/or vegetation, are outlined.

  11. Evaluation of left atrial function by multidetector computed tomography before left atrial radiofrequency-catheter ablation: Comparison of a manual and automated 3D volume segmentation method

    International Nuclear Information System (INIS)

    Wolf, Florian; Ourednicek, Petr; Loewe, Christian; Richter, Bernhard; Goessinger, Heinz David; Gwechenberger, Marianne; Plank, Christina; Schernthaner, Ruediger Egbert; Toepker, Michael; Lammer, Johannes; Feuchtner, Gudrun M.

    2010-01-01

    Introduction: The purpose of this study was to compare a manual and automated 3D volume segmentation tool for evaluation of left atrial (LA) function by 64-slice multidetector-CT (MDCT). Methods and materials: In 33 patients with paroxysmal atrial fibrillation a MDCT scan was performed before radiofrequency-catheter ablation. Atrial function (minimal volume (LAmin), maximal volume (LAmax), stroke volume (SV), ejection fraction (EF)) was evaluated by two readers using a manual and an automatic tool and measurement time was evaluated. Results: Automated LA volume segmentation failed in one patient due to low LA enhancement (103HU). Mean LAmax, LAmin, SV and EF were 127.7 ml, 93 ml, 34.7 ml, 27.1% by the automated, and 122.7 ml, 89.9 ml, 32.8 ml, 26.3% by the manual method with no significant difference (p > 0.05) and high Pearsons correlation coefficients (r = 0.94, r = 0.94, r = 0.82 and r = 0.85, p < 0.0001), respectively. The automated method was significantly faster (p < 0.001). Interobserver variability was low for both methods with Pearson's correlation coefficients between 0.98 and 0.99 (p < 0.0001). Conclusions: Evaluation of LA volume and function with 64-slice MDCT is feasible with a very low interobserver variability. The automatic method is as accurate as the manual method but significantly less time consuming permitting a routine use in clinical practice before RF-catheter ablation.

  12. Software documentation and user's manual for fish-impingement sampling design and estimation method computer programs

    International Nuclear Information System (INIS)

    Murarka, I.P.; Bodeau, D.J.

    1977-11-01

    This report contains a description of three computer programs that implement the theory of sampling designs and the methods for estimating fish-impingement at the cooling-water intakes of nuclear power plants as described in companion report ANL/ES-60. Complete FORTRAN listings of these programs, named SAMPLE, ESTIMA, and SIZECO, are given and augmented with examples of how they are used

  13. Structures manual

    Science.gov (United States)

    2001-01-01

    This manual was written as a guide for use by design personnel in the Vermont Agency of Transportation Structures Section. This manual covers the design responsibilities of the Section. It does not cover other functions that are a part of the Structu...

  14. Quality Manual

    Science.gov (United States)

    Koch, Michael

    The quality manual is the “heart” of every management system related to quality. Quality assurance in analytical laboratories is most frequently linked with ISO/IEC 17025, which lists the standard requirements for a quality manual. In this chapter examples are used to demonstrate, how these requirements can be met. But, certainly, there are many other ways to do this.

  15. Operational inspections

    International Nuclear Information System (INIS)

    Bystersky, M.

    1997-01-01

    Special equipment is described, designed for inspection of reactor pressure vessels performed from the inside. Central shaft manipulator ZMM-5 is available for crack detection control using ultrasound and eddy currents, for visual check of surfaces, repair works at the reactor pressure vessel, and hardness measurements. The manipulator consists of the manipulator bridge, a cable container, shaft segments, a control mechanism and auxiliary parts. Eight inspections were performed at the Bohunice nuclear power plant and two at the Paks nuclear power plant. (M.D.)

  16. UAV Low Altitude Photogrammetry for Power Line Inspection

    Directory of Open Access Journals (Sweden)

    Yong Zhang

    2017-01-01

    Full Text Available When the distance between an obstacle and a power line is less than the discharge distance, a discharge arc can be generated, resulting in the interruption of power supplies. Therefore, regular safety inspections are necessary to ensure the safe operation of power grids. Tall vegetation and buildings are the key factors threatening the safe operation of extra high voltage transmission lines within a power line corridor. Manual or laser intensity direction and ranging (LiDAR based inspections are time consuming and expensive. To make safety inspections more efficient and flexible, a low-altitude unmanned aerial vehicle (UAV remote-sensing platform, equipped with an optical digital camera, was used to inspect power line corridors. We propose a semi-patch matching algorithm based on epipolar constraints, using both the correlation coefficient (CC and the shape of its curve to extract three dimensional (3D point clouds for a power line corridor. We use a stereo image pair from inter-strip to improve power line measurement accuracy by transforming the power line direction to an approximately perpendicular to epipolar line. The distance between the power lines and the 3D point cloud is taken as a criterion for locating obstacles within the power line corridor automatically. Experimental results show that our proposed method is a reliable, cost effective, and applicable way for practical power line inspection and can locate obstacles within the power line corridor with accuracy better than ±0.5 m.

  17. Development of Inspection Robots for Bridge Cables

    Directory of Open Access Journals (Sweden)

    Hae-Bum Yun

    2013-01-01

    Full Text Available This paper presents the bridge cable inspection robot developed in Korea. Two types of the cable inspection robots were developed for cable-suspension bridges and cable-stayed bridge. The design of the robot system and performance of the NDT techniques associated with the cable inspection robot are discussed. A review on recent advances in emerging robot-based inspection technologies for bridge cables and current bridge cable inspection methods is also presented.

  18. Development of inspection robots for bridge cables.

    Science.gov (United States)

    Yun, Hae-Bum; Kim, Se-Hoon; Wu, Liuliu; Lee, Jong-Jae

    2013-01-01

    This paper presents the bridge cable inspection robot developed in Korea. Two types of the cable inspection robots were developed for cable-suspension bridges and cable-stayed bridge. The design of the robot system and performance of the NDT techniques associated with the cable inspection robot are discussed. A review on recent advances in emerging robot-based inspection technologies for bridge cables and current bridge cable inspection methods is also presented.

  19. Information-Driven Inspections

    International Nuclear Information System (INIS)

    Laughter, Mark D.; Whitaker, J. Michael; Lockwood, Dunbar

    2010-01-01

    New uranium enrichment capacity is being built worldwide in response to perceived shortfalls in future supply. To meet increasing safeguards responsibilities with limited resources, the nonproliferation community is exploring next-generation concepts to increase the effectiveness and efficiency of safeguards, such as advanced technologies to enable unattended monitoring of nuclear material. These include attribute measurement technologies, data authentication tools, and transmission and security methods. However, there are several conceptual issues with how such data would be used to improve the ability of a safeguards inspectorate such as the International Atomic Energy Agency (IAEA) to reach better safeguards conclusions regarding the activities of a State. The IAEA is pursuing the implementation of information-driven safeguards, whereby all available sources of information are used to make the application of safeguards more effective and efficient. Data from continuous, unattended monitoring systems can be used to optimize on-site inspection scheduling and activities at declared facilities, resulting in fewer, better inspections. Such information-driven inspections are the logical evolution of inspection planning - making use of all available information to enhance scheduled and randomized inspections. Data collection and analysis approaches for unattended monitoring systems can be designed to protect sensitive information while enabling information-driven inspections. A number of such inspections within a predetermined range could reduce inspection frequency while providing an equal or greater level of deterrence against illicit activity, all while meeting operator and technology holder requirements and reducing inspector and operator burden. Three options for using unattended monitoring data to determine an information-driven inspection schedule are to (1) send all unattended monitoring data off-site, which will require advances in data analysis techniques to

  20. Computer-based automated left atrium segmentation and volumetry from ECG-gated coronary CT angiography data. Comparison with manual slice segmentation and ultrasound planimetric methods

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, R.W.; Kraus, B.; Kerl, J.M.; Lehnert, T.; Vogl, T.J. [Universitaetsklinikum Frankfurt (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Bernhardt, D.; Vega-Higuera, F. [Siemens AG, Healthcare Sector, Forchheim (Germany). Computed Tomography; Ackermann, H. [Universitaetsklinikum Frankfurt (Germany). Inst. fuer Biostatistik und Mathematische Modellierung

    2010-12-15

    Purpose: Enlargement of the left atrium is a risk factor for cardiovascular or cerebrovascular events. We evaluated the performance of prototype software for fully automated segmentation and volumetry of the left atrium. Materials and Methods: In 34 retrospectively ECG-gated coronary CT angiography scans, the end-systolic (LAVsys) and end-diastolic (LAVdia) volume of the left atrium was calculated fully automatically by prototype software. Manual slice segmentation by two independent experienced radiologists served as the reference standard. Furthermore, two independent observers calculated the LAV utilizing two ultrasound planimetric methods ('area length' and 'prolate ellipse') on CTA images. Measurement periods were compared for all methods. Results: The left atrial volumes calculated with the prototype software were in excellent agreement with the results from manual slice segmentation (r = 0.97 - 0.99; p < 0.001; Bland-Altman) with excellent interobserver agreement between both radiologists (r = 0.99; p < 0.001). Ultrasound planimetric methods clearly showed a higher variation (r = 0.72 - 0.86) with moderate interobserver agreement (r = 0.51 - 0.79). The measurement period was significantly lower with the software (267 {+-} 28 sec; p < 0.001) than with ultrasound methods (431 {+-} 68 sec) or manual slice segmentation (567 {+-} 91 sec). Conclusion: The prototype software showed excellent agreement with manual slice segmentation with the least time consumption. This will facilitate the routine assessment of the LA volume from coronary CTA data and therefore risk stratification. (orig.)

  1. Magnetic particle inspection

    Science.gov (United States)

    Sastri, Sankar

    1990-01-01

    The purpose of this experiment is to familiarize the student with magnetic particle inspection and relate it to classification of various defects. Magnetic particle inspection is a method of detecting the presence of cracks, laps, tears, inclusions, and similar discontinuities in ferromagnetic materials such as iron and steel. This method will most clearly show defects that are perpendicular to the magnetic field. The Magnaglo method uses a liquid which is sprayed on the workpiece to be inspected, and the part is magnetized at the same time. The workpiece is then viewed under a black light, and the presence of discontinuity is shown by the formation of a bright indication formed by the magnetic particles over the discontinuity. The equipment and experimental procedures are described.

  2. Application of condition-based HRA method for a manual actuation of the safety features in a nuclear power Plant

    International Nuclear Information System (INIS)

    Kang, Hyun Gook; Jang, Seung-Cheol

    2006-01-01

    A practical approach to develop a more realistic fault-tree model with a consideration of various conditions endured by a human operator is proposed. In safety-critical systems, the generation failure of an actuation signal is caused by the concurrent failures of the automated systems and an operator action. These two sources of safety signals are complicatedly correlated. The failures of sensors or automated systems will cause a lack of necessary information for a human operator and result in error-forcing contexts such as the loss of corresponding alarms and indications. It is well known that the error-forcing contexts largely affect the operator's performance. An automated system which consists of multiple processing channels and complex components is also affected by the availability of the sensors. This paper proposes a condition-based human reliability assessment (CBHRA) method in order to address these complicated conditions in a practical way. We apply the CBHRA method to the manual actuation of the safety features such as a reactor trip and auxiliary feedwater actuation in Korean Standard Nuclear Power Plants. Even the human error probability of each given condition is simply assumed, the application results prove that the CBHRA effectively accommodates the complicated error-forcing contexts into the fault trees

  3. Hippocampal volume change measurement: Quantitative assessment of the reproducibility of expert manual outlining and the automated methods FreeSurfer and FIRST

    NARCIS (Netherlands)

    Mulder, E.R.; de Jong, R.A.; Knol, D.L.; van Schijndel, R.A.; Cover, K.S.; Visser, P.J.; Barkhof, F.; Vrenken, H.

    2014-01-01

    Background: To measure hippocampal volume change in Alzheimer's disease (AD) or mild cognitive impairment (MCI), expert manual delineation is often used because of its supposed accuracy. It has been suggested that expert outlining yields poorer reproducibility as compared to automated methods, but

  4. Myocardial infarct sizing by late gadolinium-enhanced MRI: Comparison of manual, full-width at half-maximum, and n-standard deviation methods.

    Science.gov (United States)

    Zhang, Lin; Huttin, Olivier; Marie, Pierre-Yves; Felblinger, Jacques; Beaumont, Marine; Chillou, Christian DE; Girerd, Nicolas; Mandry, Damien

    2016-11-01

    To compare three widely used methods for myocardial infarct (MI) sizing on late gadolinium-enhanced (LGE) magnetic resonance (MR) images: manual delineation and two semiautomated techniques (full-width at half-maximum [FWHM] and n-standard deviation [SD]). 3T phase-sensitive inversion-recovery (PSIR) LGE images of 114 patients after an acute MI (2-4 days and 6 months) were analyzed by two independent observers to determine both total and core infarct sizes (TIS/CIS). Manual delineation served as the reference for determination of optimal thresholds for semiautomated methods after thresholding at multiple values. Reproducibility and accuracy were expressed as overall bias ± 95% limits of agreement. Mean infarct sizes by manual methods were 39.0%/24.4% for the acute MI group (TIS/CIS) and 29.7%/17.3% for the chronic MI group. The optimal thresholds (ie, providing the closest mean value to the manual method) were FWHM30% and 3SD for the TIS measurement and FWHM45% and 6SD for the CIS measurement (paired t-test; all P > 0.05). The best reproducibility was obtained using FWHM. For TIS measurement in the acute MI group, intra-/interobserver agreements, from Bland-Altman analysis, with FWHM30%, 3SD, and manual were -0.02 ± 7.74%/-0.74 ± 5.52%, 0.31 ± 9.78%/2.96 ± 16.62% and -2.12 ± 8.86%/0.18 ± 16.12, respectively; in the chronic MI group, the corresponding values were 0.23 ± 3.5%/-2.28 ± 15.06, -0.29 ± 10.46%/3.12 ± 13.06% and 1.68 ± 6.52%/-2.88 ± 9.62%, respectively. A similar trend for reproducibility was obtained for CIS measurement. However, semiautomated methods produced inconsistent results (variabilities of 24-46%) compared to manual delineation. The FWHM technique was the most reproducible method for infarct sizing both in acute and chronic MI. However, both FWHM and n-SD methods showed limited accuracy compared to manual delineation. J. Magn. Reson. Imaging 2016;44:1206-1217. © 2016 International Society for Magnetic Resonance in Medicine.

  5. HVAC system operation manual of IMEF

    International Nuclear Information System (INIS)

    Baek, Sang Yeol; Park, Dae Kyu; Ahn, Sang Bok; Ju, Yong Sun.

    1997-06-01

    This manual is operation procedures of the IMEF(Irradiated Material Examination Facility) HVAC(Heating, Ventilation and Air Conditioning) System. General operation procedures and test method of the IMEF HVAC system are described. The manual is as follows; 1. HVAC system operation manual 2. HVAC system management guide 3. HVAC system maintenance manual 4. HVAC system air velocity and flowrate measurement manual 5. HVAC system HEPA filter leak test manual 6. HVAC system charcoal filter leak test manual 7. HVAC system HEPA and charcoal filter exchange manual. (author). 8 tabs

  6. Correlation of the manual compaction hammer with mechanical hammers for the Marshall method of design for asphaltic concrete.

    Science.gov (United States)

    1964-09-01

    The purpose of this investigation was to establish, through a series of correlations, the compactive effort (number of blows) needed using the mechanical hammers to yield similar physical properties obtained with 75 blows of the manual hammer.

  7. User manual for version 4.3 of the Tripoli-4 Monte-Carlo method particle transport computer code

    International Nuclear Information System (INIS)

    Both, J.P.; Mazzolo, A.; Peneliau, Y.; Petit, O.; Roesslinger, B.

    2003-01-01

    This manual relates to Version 4.3 TRIPOLI-4 code. TRIPOLI-4 is a computer code simulating the transport of neutrons, photons, electrons and positrons. It can be used for radiation shielding calculations (long-distance propagation with flux attenuation in non-multiplying media) and neutronic calculations (fissile medium, criticality or sub-criticality basis). This makes it possible to calculate k eff (for criticality), flux, currents, reaction rates and multi-group cross-sections. TRIPOLI-4 is a three-dimensional code that uses the Monte-Carlo method. It allows for point-wise description in terms of energy of cross-sections and multi-group homogenized cross-sections and features two modes of geometrical representation: surface and combinatorial. The code uses cross-section libraries in ENDF/B format (such as JEF2-2, ENDF/B-VI and JENDL) for point-wise description cross-sections in APOTRIM format (from the APOLLO2 code) or a format specific to TRIPOLI-4 for multi-group description. (authors)

  8. Evaluation of the PREVI® Isola automated seeder system compared to reference manual inoculation for antibiotic susceptibility testing by the disk diffusion method.

    Science.gov (United States)

    Le Page, S; van Belkum, A; Fulchiron, C; Huguet, R; Raoult, D; Rolain, J-M

    2015-09-01

    The disk diffusion (DD) method remains the most popular manual technique for antibiotic susceptibility testing (AST) in clinical microbiology laboratories. This is because of its simplicity, reproducibility, and limited cost compared to (automated) microdilution systems, which are usually less sensitive at detecting certain important mechanisms of resistance. Here, we evaluate the PREVI® Isola automated seeder system using a new protocol for spreading bacterial suspensions (eight deposits of calibrated inocula of bacteria, followed by two rounds of rotation) in comparison with manual DD reference testing on a large series of clinical and reference strains. The average time required for seeding one agar plate for DD with this new protocol was 51 s per plate, i.e., 70 agar plates/h. Reproducibility and repeatability was assessed on three reference and three randomly chosen clinical strains, as usually requested by the European Committee on Antimicrobial Susceptibility Testing (EUCAST), and was excellent compared to the manual method. The standard deviations of zones of growth inhibition showed no statistical discrimination. The correlation between the two methods, assessed using 294 clinical isolates and a panel of six antibiotics (n = 3,528 zones of growth inhibition measured), was excellent, with a correlation coefficient of 0.977. The new PREVI® Isola protocol adapted for DD had a sensitivity of 99 % and a specificity of 100 % compared to the manual technique for interpreting DD as recommended by the EUCAST.

  9. Evolution of the Ultrasonic Inspection of Heavy Rotor Forgings Over the Last Decades

    Science.gov (United States)

    Zimmer, A.; Vrana, J.; Meiser, J.; Maximini, W.; Blaes, N.

    2010-02-01

    All types of heavy forgings that are used in energy machine industry, rotor shafts as well as discs, retaining rings or tie bolts are subject to extensive nondestructive inspections before they are delivered to the customer. Due to the availability of the parts in simple shapes, these forgings are very well suited for full volmetric inspections using ultrasound. In the beginning, these inspections were carried out manually, using straight beam probes and analogue equipment. Higher requirements in reliability, efficiency, safety and power output in the machines have lead to higher requirements for the ultrasonic inspection in the form of more scanning directions, higher sensitivity demands and improved documentation means. This and the increasing use of high alloy materials for ever growing parts, increase the need for more and more sophisticated methods for testing the forgings. Angle scans and sizing technologies like DGS have been implemented, and for more than 15 years now, mechanized and automated inspections have gained importance since they allow better documentation as well as easier evaluation of the recorded data using different views (B- C- or D-Scans), projections or tomography views. The latest major development has been the availability of phased array probes to increase the flexibility of the inspection systems. Many results of the ongoing research in ultrasonic's have not been implemented yet. Today's availability of fast computers, large and fast data storages allows saving RF inspection data and applying sophisticated signal processing methods. For example linear diffraction tomography methods like SAFT offer tools for 3D reconstruction of inspection data, simplifying sizing and locating of defects as well as for improving signal to noise ratios. While such methods are already applied in medical ultrasonic's, they are still to be implemented in the steel industry. This paper describes the development of the ultrasonic inspection of heavy forgings

  10. [Evaluation of artificial digestion method on inspection of meat for Trichinella spiralis contamination and influence of the method on muscle larvae recovery].

    Science.gov (United States)

    Wang, Guo-Ying; Du, Jing-Fang; Dun, Guo-Qing; Sun, Wei-Li; Wang, Jin-Xi

    2011-04-01

    To evaluate the effect of artificial digestion method on inspection of meat for Trichinella spiralis contamination and its influence on activity and infectivity of muscle larvae. The mice were inoculated orally with 100 muscle larvae of T. spiralis and sacrificed on the 30th day following the infection. The muscle larvae of T. spiralis were recovered by three different test protocols employing variations of the artificial digestion method, i.e. the first test protocol evaluating digestion for 2 hours (magnetic stirrer method), the second test protocol evaluating digestion for 12 hours, and the third test protocol evaluating digestion for 20 hours. Each test group included ten samples, and each of which included 300 encapsulated larvae. Meanwhile, the activity of the recovered muscle larvae was also assessed. Forty mice were randomly divided into a control group and three digestion groups, so 4 groups (with 10 mice per group) in total. In the control group, each mouse was orally inoculated with 100 encapsulated larvae of T. spiralis. In all of the digestion test groups, each mouse was orally inoculated with 100 muscle larvae of T. spiralis. The larvae were then recovered from the different three test groups by the artificial digestion protocol variations. All the infected mice were sacrificed on the 30th day following the infection, and the muscle larvae of T. spiralis were examined respectively by the diaphragm compression method and the magnetic stirrer method. The muscle larvae detection rates were 78.47%, 76.73%, and 68.63%, the death rates were 0.59%, 4.60%, and 7.43%, and the reduction rates were 60.56%, 61.94%, and 73.07%, in the Test Group One (2-hour digestion), Test Group Two (12-hour digestion) and Test Group Three (20-hour digestion), respectively. The magnetic stirrer method (2-hour digestion method) is superior to both 12-hour digestion and 20-hour digestion methods when assessed by the detection rate, activity and infectivity of muscle larvae.

  11. An in-service inspection method: the use of focused probes for the detection and sizing in DDT Plates 1 and 2

    International Nuclear Information System (INIS)

    Birac, A.M.; Pincemaille, G.; Saglio, R.; Cattiauz, G.; Morisseau, P.

    1983-01-01

    As part of the DDT programme to evaluate the nondestructive testing methods used during the in-service inspection (ISI) of PWR vessels, the UKAEA asked the CEA-STA-SCND to perform the ultrasonic examination of two test-plates. Each plate was bisected across its full width by a full-thickness butt-weld in which calibrated defects of various natures, dimensions, orientations have been inserted. It was required that the implementation of control, the equipment and the subsequent data analysis represent as nearly as possible the French procedure in force during the pre-service and in-service inspection of a PWR vessel. As suggested by the UKAEA, to evaluate the influence of examiners on the results, the examinations have been carried out twice by two independent teams: one from the CEA-STA-SCND and the second from INTERCONTROLE (a CEA subsidiary company). Procedure and results are given. (author)

  12. Research methods to develop Measures of Effectiveness of the United States Coast Guard`s Vessel Inspection and Boarding Program. Volume 2, Main report

    Energy Technology Data Exchange (ETDEWEB)

    Wheeler, T.; Cox, R. [Sandia National Labs., Albuquerque, NM (United States); Gawande, K. [New Mexico Univ., Albuquerque, NM (United States). Dept. of Economics; Stone, R.; Waisel, L.; Wallace, W.A. [Rensselaer Polytechnic Inst., Troy, New York (United States). Dept. of Decision Sciences and Engineering Systems

    1995-04-01

    The primary objective of this study is to provide Measures of Effectiveness (MOEs) of the US Coast Guard Marine Inspection and Boarding Program based on objective scientific methods. A secondary objective of the study is to provide USCG management with a methodologically and theoretically sound aid to effective policy decision-making. The MOEs constructed in this study are specific to the Marine Inspection and Boarding Program, but the methodology of the study is based on sound theoretical principles that are probably applicable to a range of USCG activities. Hence the methodology applied equally to other important USCG programs and can be similarly used to measure their effectiveness and as an aid to decision-making.

  13. Inspection of disposal canisters components

    International Nuclear Information System (INIS)

    Pitkaenen, J.

    2013-12-01

    This report presents the inspection techniques of disposal canister components. Manufacturing methods and a description of the defects related to different manufacturing methods are described briefly. The defect types form a basis for the design of non-destructive testing because the defect types, which occur in the inspected components, affect to choice of inspection methods. The canister components are to nodular cast iron insert, steel lid, lid screw, metal gasket, copper tube with integrated or separate bottom, and copper lid. The inspection of copper material is challenging due to the anisotropic properties of the material and local changes in the grain size of the copper material. The cast iron insert has some acoustical material property variation (attenuation, velocity changes, scattering properties), which make the ultrasonic inspection demanding from calibration point of view. Mainly three different methods are used for inspection. Ultrasonic testing technique is used for inspection of volume, eddy current technique, for copper components only, and visual testing technique are used for inspection of the surface and near surface area

  14. The research of the test-class method based on interface object in the software integration test of the large container inspection system

    International Nuclear Information System (INIS)

    Sun Shaohua; Chen Zhiqiang; Zhang Li; Gao Wenhuan; Kang Kejun

    2000-01-01

    Software test is the important stage in software process. The has been mature theory, method and model for unit test in practice. But for integration test, there is not regular method to adhere to. The author presents a new method, developed during the development of the large container inspection system, named test class method based on interface object. In this method a set of basic test-class based on the concept of class in the object-oriented method is established and the method of combining the interface graph and the class set is used to describe the test process. So the strict control and the scientific management for the test process are achieved. The conception of test database is introduced in this method, thus the traceability and the repeatability of test process are improved

  15. FINAS. Example manual. 2

    International Nuclear Information System (INIS)

    Iwata, Koji; Tsukimori, Kazuyuki; Ueno, Mutsuo

    2003-12-01

    FINAS is a general purpose structural analysis computer program which was developed by Japan Nuclear Cycle Development Institute for the analysis of static, dynamic and thermal responses of elastic and inelastic structures by the finite element method. This manual contains typical analysis examples that illustrate applications of FINAS to a variety of structural engineering problems. The first part of this manual presents fundamental examples in which numerical solutions by FINAS are compared with some analytical reference solutions, and the second part of this manual presents more complex examples intended for practical application. All the input data images and principal results for each problem are included in this manual for beginners' convenience. All the analyses are performed by using the FINAS Version 13.0. (author)

  16. Hippocampal volume change measurement: quantitative assessment of the reproducibility of expert manual outlining and the automated methods FreeSurfer and FIRST.

    Science.gov (United States)

    Mulder, Emma R; de Jong, Remko A; Knol, Dirk L; van Schijndel, Ronald A; Cover, Keith S; Visser, Pieter J; Barkhof, Frederik; Vrenken, Hugo

    2014-05-15

    To measure hippocampal volume change in Alzheimer's disease (AD) or mild cognitive impairment (MCI), expert manual delineation is often used because of its supposed accuracy. It has been suggested that expert outlining yields poorer reproducibility as compared to automated methods, but this has not been investigated. To determine the reproducibilities of expert manual outlining and two common automated methods for measuring hippocampal atrophy rates in healthy aging, MCI and AD. From the Alzheimer's Disease Neuroimaging Initiative (ADNI), 80 subjects were selected: 20 patients with AD, 40 patients with mild cognitive impairment (MCI) and 20 healthy controls (HCs). Left and right hippocampal volume change between baseline and month-12 visit was assessed by using expert manual delineation, and by the automated software packages FreeSurfer (longitudinal processing stream) and FIRST. To assess reproducibility of the measured hippocampal volume change, both back-to-back (BTB) MPRAGE scans available for each visit were analyzed. Hippocampal volume change was expressed in μL, and as a percentage of baseline volume. Reproducibility of the 1-year hippocampal volume change was estimated from the BTB measurements by using linear mixed model to calculate the limits of agreement (LoA) of each method, reflecting its measurement uncertainty. Using the delta method, approximate p-values were calculated for the pairwise comparisons between methods. Statistical analyses were performed both with inclusion and exclusion of visibly incorrect segmentations. Visibly incorrect automated segmentation in either one or both scans of a longitudinal scan pair occurred in 7.5% of the hippocampi for FreeSurfer and in 6.9% of the hippocampi for FIRST. After excluding these failed cases, reproducibility analysis for 1-year percentage volume change yielded LoA of ±7.2% for FreeSurfer, ±9.7% for expert manual delineation, and ±10.0% for FIRST. Methods ranked the same for reproducibility of 1

  17. The research of the test-class method based on interface object in the software integration test of the large container inspection system

    International Nuclear Information System (INIS)

    Sun Shaohua; Chen Zhiqiang; Zhang Li; Gao Wenhuan; Kang Kejun

    2001-01-01

    Software test is the important stage in software process. There has been mature theory, method and model for unit test in practice. But for integration test, there is not regular method to adhere to. The author presents a new method, developed during the development of the large container inspection system, named test-class method based on interface object. A set of basis test-class based on the concept of class in the object-oriented method is established and the method of combining the interface graph and the class set is used to describe the test process. So the strict control and the scientific management for the test process are achieved. The conception of test database is introduced in this method, thus the traceability and the repeatability of test process are improved

  18. Evaluation of left atrial function by multidetector computed tomography before left atrial radiofrequency-catheter ablation: Comparison of a manual and automated 3D volume segmentation method

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Florian, E-mail: florian.wolf@meduniwien.ac.a [Department of Radiology, Medical University of Vienna, Vienna (Austria); Ourednicek, Petr [Philips Medical Systems, Prague (Czech Republic); Loewe, Christian [Department of Radiology, Medical University of Vienna, Vienna (Austria); Richter, Bernhard; Goessinger, Heinz David; Gwechenberger, Marianne [Department of Cardiology, Medical University of Vienna, Vienna (Austria); Plank, Christina; Schernthaner, Ruediger Egbert; Toepker, Michael; Lammer, Johannes [Department of Radiology, Medical University of Vienna, Vienna (Austria); Feuchtner, Gudrun M. [Department of Radiology, Innsbruck Medical University, Innsbruck (Austria); Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland)

    2010-08-15

    Introduction: The purpose of this study was to compare a manual and automated 3D volume segmentation tool for evaluation of left atrial (LA) function by 64-slice multidetector-CT (MDCT). Methods and materials: In 33 patients with paroxysmal atrial fibrillation a MDCT scan was performed before radiofrequency-catheter ablation. Atrial function (minimal volume (LAmin), maximal volume (LAmax), stroke volume (SV), ejection fraction (EF)) was evaluated by two readers using a manual and an automatic tool and measurement time was evaluated. Results: Automated LA volume segmentation failed in one patient due to low LA enhancement (103HU). Mean LAmax, LAmin, SV and EF were 127.7 ml, 93 ml, 34.7 ml, 27.1% by the automated, and 122.7 ml, 89.9 ml, 32.8 ml, 26.3% by the manual method with no significant difference (p > 0.05) and high Pearsons correlation coefficients (r = 0.94, r = 0.94, r = 0.82 and r = 0.85, p < 0.0001), respectively. The automated method was significantly faster (p < 0.001). Interobserver variability was low for both methods with Pearson's correlation coefficients between 0.98 and 0.99 (p < 0.0001). Conclusions: Evaluation of LA volume and function with 64-slice MDCT is feasible with a very low interobserver variability. The automatic method is as accurate as the manual method but significantly less time consuming permitting a routine use in clinical practice before RF-catheter ablation.

  19. Biosafety Manual

    Energy Technology Data Exchange (ETDEWEB)

    King, Bruce W.

    2010-05-18

    Work with or potential exposure to biological materials in the course of performing research or other work activities at Lawrence Berkeley National Laboratory (LBNL) must be conducted in a safe, ethical, environmentally sound, and compliant manner. Work must be conducted in accordance with established biosafety standards, the principles and functions of Integrated Safety Management (ISM), this Biosafety Manual, Chapter 26 (Biosafety) of the Health and Safety Manual (PUB-3000), and applicable standards and LBNL policies. The purpose of the Biosafety Program is to protect workers, the public, agriculture, and the environment from exposure to biological agents or materials that may cause disease or other detrimental effects in humans, animals, or plants. This manual provides workers; line management; Environment, Health, and Safety (EH&S) Division staff; Institutional Biosafety Committee (IBC) members; and others with a comprehensive overview of biosafety principles, requirements from biosafety standards, and measures needed to control biological risks in work activities and facilities at LBNL.

  20. GRACE manual

    International Nuclear Information System (INIS)

    Ishikawa, T.; Kawabata, S.; Shimizu, Y.; Kaneko, T.; Kato, K.; Tanaka, H.

    1993-02-01

    This manual is composed of three kinds of objects, theoretical background for calculating the cross section of elementary process, usage and technical details of the GRACE system. Throughout this manual we take the tree level process e + e - → W + W - γ as an example, including the e ± -scalar boson interactions. The real FORTRAN source code for this process is attached in the relevant sections as well as the results of calculation, which might be a great help for understanding the practical use of the system. (J.P.N.)

  1. Implementation of the INSPECT software package for statistical calculation in nuclear material accountability

    International Nuclear Information System (INIS)

    Marzo, M.A.S.

    1986-01-01

    The INSPECT software package was developed in the Pacific Northwest Laboratory for statistical calculations in nuclear material accountability. The programs apply the inspection and evaluation methodology described in Part of the Safeguards Technical Manual. In this paper the implementation of INSPECT at the Safeguards Division of CNEN, and the main characteristics of INSPECT are described. The potential applications of INSPECT to the nuclear material accountability is presented. (Author) [pt

  2. Inter-laboratory variation in in vitro gas production profiles of some selected feeds, using both manual and automated methods

    NARCIS (Netherlands)

    Rymer, C.; Williams, B.A.; Brooks, A.E.; Davies, D.R.; Givens, D.I.

    2005-01-01

    A study was conducted to estimate variation among laboratories and between manual and automated techniques of measuring pressure on the resulting gas production profiles (GPP). Eight feeds (molassed sugarbeet feed, grass silage, maize silage, soyabean hulls, maize gluten feed, whole crop wheat

  3. Designing Pattern Recognition-Based Method for Fast Visual Inspection of the Bucket Wheel Excavator Lattice Structure

    Science.gov (United States)

    Risteiu, M.; Lorincz, A.; Dobra, R.; Dasic, P.; Andras, I.; Roventa, M.

    2017-06-01

    The proposed paper shows some experimental results of a research in metallic structures inspection by using a high definition camera controller by high processing capabilities. The dedicated ARM Cortex-M4 initializes the ARM Cortex-M0 system for image acquiring. Then, by programming options, we are action for patterns (abnormal situations like metal cracks, or discontinuities) types and tuning, for enabling overexposure highlighting and adjusting camera brightness/exposure, to adjust minimum brightness, and to adjust the pattern’s teach threshold. The proposed system has been tested in normal lighting conditions from the typical site.

  4. In-operation inspection technology development 'development of a rational maintenance management method for light-water reactor plant'

    International Nuclear Information System (INIS)

    Matsumoto, K.; Sanoh, J.; Uhara, Y.; Takeshima, K.; Tani, M.; O'Shima, E.

    2001-01-01

    In 1985, the Japanese national project named 'In-Operation Inspection Technology Development (IOI)' was initiated, as a part of the activities for advancing the LWR(light water reactor)technology in Japan. This project developed the techniques for in-operation monitoring and detecting of early anomalies of nuclear power equipment such as rotating machines, valves and piping. Further, the estimation systems for diagnosing and predicting a degradation rate of these items of equipment were constructed. Based on these results, a new maintenance management technology was constructed. This paper describes the outline of the new maintenance management concept. (authors)

  5. Early detection of cervical cancer with visual inspection methods: a summary of completed and on-going studies in India

    Directory of Open Access Journals (Sweden)

    Sankaranarayanan R

    2003-01-01

    Full Text Available India is a high-risk country for cervical cancer which accounts a quarter (126 000 new cases, 71 000 deaths around 2 000 of the world burden. The age-standardized incidence rates range from 16-55 per 100 000 women in different regions with particularly high rates in rural areas. Control of cervical cancer by early detection and treatment is a priority of the National Cancer Control Programme of India. There are no organized cytology screening programmes in the country. The technical and financial constraints to organize cytology screening have encouraged the evaluation of visual inspection approaches as potential alternatives to cervical cytology in India. Four types of visual detection approaches for cervical neoplasia are investigated in India: a naked eye inspection without acetic acid application, widely known as 'downstaging'; b naked eye inspection after application of 3-5% acetic acid (VIA; c VIA using magnification devices (VIAM; d visual inspection after the application of Lugol's iodine (VILI. Downstaging has been shown to be poorly sensitive and specific to detect cervical neoplasia and is no longer considered as a suitable screening test for cervical cancer. VIA, VIAM and VILI are currently being investigated in multicentre cross-sectional studies (without verification bias, in which cytology and HPV testing are also simultaneously evaluated, and the results of these investigations will be available in 2003. These studies will provide valuable information on the average, comparative test performances in detecting high-grade cervical cancer precursors and cancer. Results from pooled analysis of data from two completed studies indicated an approximate sensitivity of 93.4% and specificity of 85.1% for VIA to detect CIN 2 or worse lesions; the corresponding figures for cytology were 72.1% and 91.6%. The efficacy of VIA in reducing incidence of and mortality from cervical cancer and its cost-effectiveness is currently being investigated

  6. An intelligent system for real time automatic defect inspection on specular coated surfaces

    Science.gov (United States)

    Li, Jinhua; Parker, Johné M.; Hou, Zhen

    2005-07-01

    Product visual inspection is still performed manually or semi automatically in most industries from simple ceramic tile grading to complex automotive body panel paint defect and surface quality inspection. Moreover, specular surfaces present additional challenge to conventional vision systems due to specular reflections, which may mask the true location of objects and lead to incorrect measurements. There are some sophisticated visual inspection methods developed in recent years. Unfortunately, most of them are highly computational. Systems built on those methods are either inapplicable or very costly to achieve real time inspection. In this paper, we describe an integrated low-cost intelligent system developed to automatically capture, extract, and segment defects on specular surfaces with uniform color coatings. The system inspects and locates regular surface defects with lateral dimensions as small as a millimeter. The proposed system is implemented on a group of smart cameras using its on-board processing ability to achieve real time inspection. The experimental results on real test panels demonstrate the effectiveness and robustness of proposed system.

  7. Deployment Plan for Small Roving Annulus Inspection Vehicle

    International Nuclear Information System (INIS)

    Minichan, R.

    2002-01-01

    The Small Roving Annulus Inspection Vehicle (SRAIV) is a modified commercially available wall crawler designed to supplement the In-Service Inspection (ISI) of Savannah River Site (SRS) Waste tanks. The SRAIV provides an improved capability to achieve a more complete inspection of the tank walls than existing methods. The SRAIV will be deployed through annulus risers in the tank to gain access to tank walls requiring inspection. The SRAIV will be deployed using a manually operated deployment pole and will be coupled to the wall using permanent magnet wheels. Navigation will be performed from the remote console where pictorial views can be displayed from the on-board cameras. The unit will incorporate multiple UT transducers for traditional weld examination. In addition, a specially developed Tandem Synthetic Aperture Focusing Technique (TSAFT) UT scanning bridge can be attached to provide further investigation of the knuckle region while the vehicle remains on the vertical surface of the tank wall. In summary, the SRAIV will provide features that enhance and expand the capability of the SRS ISI program

  8. Airplane tire inspection by image processing techniques

    OpenAIRE

    Jovancevic , Igor; Arafat , Al; Orteu , Jean-José; Sentenac , Thierry

    2016-01-01

    International audience; In this paper, we propose a new approach to detect and inspect airplane tires. We use normalized correlation based template matching to detect tires and GrabCut segmentation method to extract them from the background. We inspect the tires condition by investigating the tire treads. Ridge based intensity profiling gives satisfying inspection results.

  9. Mechanized ultrasonic inspection of austenitic pipe systems

    International Nuclear Information System (INIS)

    Dressler, K.; Luecking, J.; Medenbach, S.

    1999-01-01

    The contribution explains the system of standard testing methods elaborated by ABB ZAQ GmbH for inspection of austenitic plant components. The inspection tasks explained in greater detail are basic materials testing (straight pipes, bends, and pipe specials), and inspection of welds and dissimilar welds. The techniques discussed in detail are those for detection and sizing of defects. (orig./CB) [de

  10. MARS CODE MANUAL VOLUME III - Programmer's Manual

    International Nuclear Information System (INIS)

    Chung, Bub Dong; Hwang, Moon Kyu; Jeong, Jae Jun; Kim, Kyung Doo; Bae, Sung Won; Lee, Young Jin; Lee, Won Jae

    2010-02-01

    Korea Advanced Energy Research Institute (KAERI) conceived and started the development of MARS code with the main objective of producing a state-of-the-art realistic thermal hydraulic systems analysis code with multi-dimensional analysis capability. MARS achieves this objective by very tightly integrating the one dimensional RELAP5/MOD3 with the multi-dimensional COBRA-TF codes. The method of integration of the two codes is based on the dynamic link library techniques, and the system pressure equation matrices of both codes are implicitly integrated and solved simultaneously. In addition, the Equation-Of-State (EOS) for the light water was unified by replacing the EOS of COBRA-TF by that of the RELAP5. This programmer's manual provides a complete list of overall information of code structure and input/output function of MARS. In addition, brief descriptions for each subroutine and major variables used in MARS are also included in this report, so that this report would be very useful for the code maintenance. The overall structure of the manual is modeled on the structure of the RELAP5 and as such the layout of the manual is very similar to that of the RELAP. This similitude to RELAP5 input is intentional as this input scheme will allow minimum modification between the inputs of RELAP5 and MARS3.1. MARS3.1 development team would like to express its appreciation to the RELAP5 Development Team and the USNRC for making this manual possible

  11. A simple and fast method for the inspection of preservatives in cheeses and cream by liquid chromatography- electrospray tandem mass spectrometry.

    Science.gov (United States)

    Molognoni, Luciano; de Sá Ploêncio, Leandro Antunes; Valese, Andressa Camargo; De Dea Lindner, Juliano; Daguer, Heitor

    2016-01-15

    In this work, a simplified extraction and short time of analysis method for the simultaneous determination of natamycin, nisin and sorbic acid in cheeses and cream by reverse phase liquid chromatography-electrospray-tandem mass spectrometry was developed. Full validation was performed according to the Commission Decision 2002/657/EC criteria and method applicability was checked on several samples, aiming to inspect their compliance with regulatory limits. The method was linear in the concentration ranges of 0-10mg kg(-1) (natamycin), 0-25mg kg(-1) (nisin) and 0 20mg kg(-1) (sorbic acid). Samples of the three most consumed types of cheese (fresh, pasta filata and ripened) in Brazil and cream (ultra high temperature and pasteurized, 20-30% fat content) were assessed. A surprising rate of non-compliance was observed, especially among ripened grated cheeses, since 80% of samples were above the maximum limit for sorbic acid with an average concentration of 2766.3±10.8mg kg(-1). Moreover, a major non-compliance for the cream samples was observed. The proposed method can be applied as an efficient tool for the inspection of preservatives in cheeses and cream. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. EML procedures manual

    International Nuclear Information System (INIS)

    Volchok, H.L.; de Planque, G.

    1982-01-01

    This manual contains the procedures that are used currently by the Environmental Measurements Laboratory of the US Department of Energy. In addition a number of analytical methods from other laboratories have been included. These were tested for reliability at the Battelle, Pacific Northwest Laboratory under contract with the Division of Biomedical and Environmental Research of the AEC. These methods are clearly distinguished. The manual is prepared in loose leaf form to facilitate revision of the procedures and inclusion of additional procedures or data sheets. Anyone receiving the manual through EML should receive this additional material automatically. The contents are as follows: (1) general; (2) sampling; (3) field measurements; (4) general analytical chemistry; (5) chemical procedures; (6) data section; (7) specifications

  13. Pressure vessel design manual

    CERN Document Server

    Moss, Dennis R

    2013-01-01

    Pressure vessels are closed containers designed to hold gases or liquids at a pressure substantially different from the ambient pressure. They have a variety of applications in industry, including in oil refineries, nuclear reactors, vehicle airbrake reservoirs, and more. The pressure differential with such vessels is dangerous, and due to the risk of accident and fatality around their use, the design, manufacture, operation and inspection of pressure vessels is regulated by engineering authorities and guided by legal codes and standards. Pressure Vessel Design Manual is a solutions-focused guide to the many problems and technical challenges involved in the design of pressure vessels to match stringent standards and codes. It brings together otherwise scattered information and explanations into one easy-to-use resource to minimize research and take readers from problem to solution in the most direct manner possible. * Covers almost all problems that a working pressure vessel designer can expect to face, with ...

  14. Operation Procedure of Inspection Equipment for TRISO-coated Fuel Particle

    International Nuclear Information System (INIS)

    Kim, S. H.; Kim, Y. K.; Cho, M. S.; Kim, Y. M.; Park, J. Y.; Kim, W. J.; Jeong, K. C.; Oh, S. C.; Lee, Y. W.

    2007-03-01

    TRISO-coated fuel particle for HTGR(high temperature gas cooled reactor) is composed of fuel kernel and coating layers. The kernel and coated particle are characterized by inspection processes for inspection items such as diameter of kernel, thickness, density and an-isotropy of coating layer. The coating thickness can be nondestructively measured by X-ray inspection equipment. The coating thickness as well as the sphericity can be also measured by optical inspection system as a ceramography method. The an-isotropy can be characterized by photometer. The density of coating layer can be measured by density column. The size and sphericity of particles can be measured by PSA(particle size analyzer). The thermo-chemical characteristics of kernel can be analyzed by TG/DTA(Thermogravimetric/Differential Thermal Analyzer). The inspection objective, equipment composition, operation principle, operation manual for each equipment was described in this operation procedure, which will be used for the characterization of inspection items described above

  15. Metrication manual

    International Nuclear Information System (INIS)

    Harper, A.F.A.; Digby, R.B.; Thong, S.P.; Lacey, F.

    1978-04-01

    In April 1978 a meeting of senior metrication officers convened by the Commonwealth Science Council of the Commonwealth Secretariat, was held in London. The participants were drawn from Australia, Bangladesh, Britain, Canada, Ghana, Guyana, India, Jamaica, Papua New Guinea, Solomon Islands and Trinidad and Tobago. Among other things, the meeting resolved to develop a set of guidelines to assist countries to change to SI and to compile such guidelines in the form of a working manual

  16. Detailed simulation of ultrasonic inspections

    International Nuclear Information System (INIS)

    Chaplin, K.R.; Douglas, S.R.; Dunford, D.

    1997-01-01

    Simulation of ultrasonic inspection of engineering components have been performed at the Chalk River Laboratories of AECL for over 10 years. The computer model, called EWE for Elastic Wave Equations, solves the Elastic Wave Equations using a novel finite difference scheme. It simulates the propagation of an ultrasonic wave from the transducer to a flaw, the scatter of waves from the flaw, and measurement of signals at a receive transducer. Regions of different materials, water and steel for example, can be simulated. In addition, regions with slightly different material properties from the parent material can be investigated. The two major types of output are displays of the ultrasonic waves inside the component and the corresponding A-scans. EPRI and other organizations have used ultrasonic models for: defining acceptable ultrasonic inspection procedures, designing and evaluating inspection techniques, and for quantifying inspection reliability. The EWE model has been applied to the inspection of large pipes in a nuclear plant, gas pipeline welds and steam generator tubes. Most recent work has dealt with the ultrasonic inspection of pressure tubes in CANDU reactors. Pressure tube inspections can reliably detect and size defects; however, there are improvements that can be made. For example, knowing the sharpness of a flaw-tip is crucial for fitness for service assessments. Computer modelling of the ultrasonic inspection of flaws with different root radius has suggested inspection techniques that provide flaw tip radius information. A preliminary investigation of these methods has been made in the laboratory. The basis for the model will be reviewed at the presentation. Then the results of computer simulations will be displayed on a PC using an interactive program that analyzes simulated A-scans. This software tool gives inspection staff direct access to the results of computer simulations. (author)

  17. HEFF---A user's manual and guide for the HEFF code for thermal-mechanical analysis using the boundary-element method

    International Nuclear Information System (INIS)

    St John, C.M.; Sanjeevan, K.

    1991-12-01

    The HEFF Code combines a simple boundary-element method of stress analysis with the closed form solutions for constant or exponentially decaying heat sources in an infinite elastic body to obtain an approximate method for analysis of underground excavations in a rock mass with heat generation. This manual describes the theoretical basis for the code, the code structure, model preparation, and step taken to assure that the code correctly performs its intended functions. The material contained within the report addresses the Software Quality Assurance Requirements for the Yucca Mountain Site Characterization Project. 13 refs., 26 figs., 14 tabs

  18. Household indoor air quality and its associations with childhood asthma in Shanghai, China: On-site inspected methods and preliminary results.

    Science.gov (United States)

    Huang, Chen; Wang, Xueying; Liu, Wei; Cai, Jiao; Shen, Li; Zou, Zhijun; Lu, Rongchun; Chang, Jing; Wei, Xiaoyang; Sun, Chanjuan; Zhao, Zhuohui; Sun, Yuexia; Sundell, Jan

    2016-11-01

    Few studies were conducted for associations of home environment with childhood health by on-site inspection in China. During 2013-2014, we conducted a case-control study with home inspection among 454 children (186 asthma children and 268 non-asthma children) in Shanghai, China. In this paper, we detailedly described the inspected methods and analyzed the preliminarily collected data. Except in winter, most residences meet the national standard for indoor temperature and relative humidity. Most living rooms had ≤1000ppm CO 2 , whereas over half of the child's bedrooms had slightly >1000ppm CO 2 during night. Most residences had notably lower than 2500cfu/m 3 airborne culturable fungi and ≤100μg/m 3 formaldehyde. More than 70% of the child's bedrooms had ≤75μg/m 3 PM 2.5 and ≤150μg/m 3 PM 10 . Indoor and outdoor concentrations of particulate matters had strong linear correlations (r=0.891-0.922; p-value indoor averaged concentration of CO 2 and particulate matters generally had negative associations with childhood history of doctor-diagnosed asthma in spring, summer, and autumn. Only in winter, indoor CO 2 concentration was significantly associated with the increased odds of childhood asthma. Our results indicated that air quality among most residences in Shanghai could meet the national standard for indoor air quality in warm seasons; but household air quality and ventilation status in winter should be greatly improved. We suspected that those "unexpected" negative associations could exist due to changes in lifestyle behaviors regarding indoor air quality after the child being diagnosed asthma by a doctor. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. An experimental implementation of the 90 .deg. compton scattering inspection method for identifying explosive materials using dual energy x-ray

    International Nuclear Information System (INIS)

    Park, Ji Sung

    2012-02-01

    In order to obtain the physical properties of an inspection object using an X-ray source, the energy-resolving X-ray method, reflecting the characteristic of continuous energy, is a very useful tool. In this study, the effective atomic number (Z eff ) and normal density (ρ) obtained by the source weighting method on a dual energy X-ray inspection system are presented and demonstrated by experimental implementation. Two X-ray beams of the suggested method were designed using the XCOMP5r code. The filter design of a high energy X-ray source was fixed as 3.5 mm Sn at 150 kVp tube voltage, and the new high energy X-ray beam was named as IN150. The filter design of a low energy X-ray source was also fixed as 0.5 mm Sn at 90 kVp tube voltage, and the new beam was named as IN90. Benchmark calculations by MCNP simulation experiments were performed using four different materials, i.e., Polyethylene, Acetal, Urethane, and TNT. The results of the benchmark calculation showed that the new method can estimate the effective atomic number and the normal density of a scattered object accurately, even when the object was arbitrarily located in samples. Finally to verify the proposed new method, scattering experiments using various polymerized compounds were carried out. The effective attenuation coefficients (μ 1 , μ 2 ) of the experiment objects at the source energies E 1 and E 2 , were calculated using scattered spectra. The effective atomic number and the normal density were then calculated by using the ratio of μ 1 to μ 2 . As a result in case of all sample geometries, the relative differences between the calculation value and the reference value for the effective atomic numbers of each material were within 14 %, and the relative differences for the normal densities were within 12 %. This observation led us to the conclusion that the new 90 .deg. Compton scattering method for identifying explosive materials using a dual-energy X-ray is valid for calculating effective

  20. Comparison of thoracolumbar motion produced by manual and Jackson-table-turning methods. Study of a cadaveric instability model.

    Science.gov (United States)

    DiPaola, Christian P; DiPaola, Matthew J; Conrad, Bryan P; Horodyski, MaryBeth; Del Rossi, Gianluca; Sawers, Andrew; Rechtine, Glenn R

    2008-08-01

    Patients who have sustained a spinal cord injury remain at risk for further neurologic deterioration until the spine is adequately stabilized. To our knowledge, no study has previously addressed the effects of different bed-to-operating room table transfer techniques on thoracolumbar spinal motion in an instability model. We hypothesized that the conventional logroll technique used to transfer patients from a supine position to a prone position on the operating room table has the potential to confer significantly more motion to the unstable thoracolumbar spine than the Jackson technique. Three-column instability was surgically created at the L1 level in seven cadavers. Two protocols were tested. The manual technique entailed performing a standard logroll of a supine cadaver to a prone position on an operating room Jackson table. The Jackson technique involved sliding the supine cadaver to the Jackson table, securing it to the table, and then rotating it into a prone position. An electromagnetic tracking device measured motion--i.e., angular motion (flexion-extension, lateral bending, and axial rotation) and linear translation (axial, medial-lateral, and anterior-posterior) between T12 and L2. The logroll technique created significantly more motion than the Jackson technique as measured with all six parameters. Manual logroll transfers produced an average of 13.8 degrees to 18.1 degrees of maximum angular displacement and 16.6 to 28.3 mm of maximum linear translation. The Jackson technique resulted in an average of 3.1 degrees to 5.8 degrees of maximum angular displacement (p patient safety. Performing the Jackson turn requires approximately half as many people as required for a manual logroll. This study suggests that the Jackson technique should be considered for supine-to-prone transfer of patients with known or suspected instability of the thoracolumbar spine.

  1. Considerations for design and use of container challenge sets for qualification and validation of visible particulate inspection.

    Science.gov (United States)

    Melchore, James A; Berdovich, Dan

    2012-01-01

    The major compendia require sterile injectable and ophthalmic drugs, to be prepared in a manner that is designed to exclude particulate matter. This requirement is satisfied by testing for subvisual particles in the laboratory and 100% inspection of all containers for the presence of visible particles. Inspection for visible particles is performed in the operations area using one of three methods. Manual inspection is based on human visual acuity, the ability of the inspector to discern between conforming and nonconforming containers, and the ability to remove nonconforming units. Semi-automated inspection is a variation of manual inspection, in which a roller conveyor handles and presents the containers to the human inspector. Fully automated inspection systems perform handling, inspection, and rejection of defective containers. All inspection methods must meet the compendial requirement for sterile drug product to be "essentially free" of visible particulates. Given the random occurrence of particles within the batch, visual detection of a particle in an individual container is probabilistic. The probability of detection for a specific particle is affected by many variables that include product attributes, container size and shape, particle composition and size, and inspection capability. The challenge set is a useful tool to assess the particle detection in a product, and it may also be used to evaluate detection of container/closure defects. While the importance of a well-designed challenge set is not always recognized or understood, it serves as the cornerstone for qualification and/or validation of all inspection methods. This article is intended to provide useful information for the design, composition, and use of container challenge sets for particulate inspection studies. Regulations require drug products intended for injection or ophthalmic use to be sterile and free of particles that could harm the patient. This requirement is meet by 100% inspection of

  2. Waste Management Technical Manual

    Energy Technology Data Exchange (ETDEWEB)

    Buckingham, J.S. [ed.

    1967-08-31

    This Manual has been prepared to provide a documented compendium of the technical bases and general physical features of Isochem Incorporated`s Waste Management Program. The manual is intended to be used as a means of training and as a reference handbook for use by personnel responsible for executing the Waste Management Program. The material in this manual was assembled by members of Isochem`s Chemical Processing Division, Battelle Northwest Laboratory, and Hanford Engineering Services between September 1965 and March 1967. The manual is divided into the following parts: Introduction, contains a summary of the overall Waste Management Program. It is written to provide the reader with a synoptic view and as an aid in understanding the subsequent parts; Feed Material, contains detailed discussion of the type and sources of feed material used in the Waste Management Program, including a chapter on nuclear reactions and the formation of fission products; Waste Fractionization Plant Processing, contains detailed discussions of the processes used in the Waste Fractionization Plant with supporting data and documentation of the technology employed; Waste Fractionization Plant Product and Waste Effluent Handling, contains detailed discussions of the methods of handling the product and waste material generated by the Waste Fractionization Plant; Plant and Equipment, describes the layout of the Waste Management facilities, arrangement of equipment, and individual equipment pieces; Process Control, describes the instruments and analytical methods used for process control; and Safety describes process hazards and the methods used to safeguard against them.

  3. An evaluation of human factors research for ultrasonic inservice inspection

    International Nuclear Information System (INIS)

    Pond, D.J.; Donohoo, D.T.; Harris, R.V. Jr.

    1998-03-01

    This work was undertaken to determine if human factors research has yielded information applicable to upgrading requirements in ASME Boiler and Pressure Vessel Code Section XI, improving methods and techniques in Section V, and/or suggesting relevant research. A preference was established for information and recommendations which have become accepted and standard practice. Manual Ultrasonic Testing/Inservice Inspection (UT/ISI) is a complex task subject to influence by dozens of variables. This review frequently revealed equivocal findings regarding effects of environmental variables as well as repeated indications that inspection performance may be more, and more reliably, influenced by the workers' social environment, including managerial practices, than by other situational variables. Also of significance are each inspector's relevant knowledge, skills, and abilities, and determination of these is seen as a necessary first step in upgrading requirements, methods, and techniques as well as in focusing research in support of such programs, While understanding the effects and mediating mechanisms of the variables impacting inspection performance is a worthwhile pursuit for researchers, initial improvements in industrial UTASI performance may be achieved by implementing practices already known to mitigate the effects of potentially adverse conditions. 52 refs., 2 tabs

  4. An evaluation of human factors research for ultrasonic inservice inspection

    Energy Technology Data Exchange (ETDEWEB)

    Pond, D.J.; Donohoo, D.T.; Harris, R.V. Jr.

    1998-03-01

    This work was undertaken to determine if human factors research has yielded information applicable to upgrading requirements in ASME Boiler and Pressure Vessel Code Section XI, improving methods and techniques in Section V, and/or suggesting relevant research. A preference was established for information and recommendations which have become accepted and standard practice. Manual Ultrasonic Testing/Inservice Inspection (UT/ISI) is a complex task subject to influence by dozens of variables. This review frequently revealed equivocal findings regarding effects of environmental variables as well as repeated indications that inspection performance may be more, and more reliably, influenced by the workers` social environment, including managerial practices, than by other situational variables. Also of significance are each inspector`s relevant knowledge, skills, and abilities, and determination of these is seen as a necessary first step in upgrading requirements, methods, and techniques as well as in focusing research in support of such programs, While understanding the effects and mediating mechanisms of the variables impacting inspection performance is a worthwhile pursuit for researchers, initial improvements in industrial UTASI performance may be achieved by implementing practices already known to mitigate the effects of potentially adverse conditions. 52 refs., 2 tabs.

  5. A pilot application of risk-informed methods to establish inservice inspection priorities for nuclear components at Surry Unit 1 Nuclear Power Station. Revision 1

    International Nuclear Information System (INIS)

    Vo, T.V.; Phan, H.K.; Gore, B.F.; Simonen, F.A.; Doctor, S.R.

    1997-02-01

    As part of the Nondestructive Evaluation Reliability Program sponsored by the US Nuclear Regulatory Commission, the Pacific Northwest National Laboratory has developed risk-informed approaches for inservice inspection plans of nuclear power plants. This method uses probabilistic risk assessment (PRA) results to identify and prioritize the most risk-important components for inspection. The Surry Nuclear Power Station Unit 1 was selected for pilot application of this methodology. This report, which incorporates more recent plant-specific information and improved risk-informed methodology and tools, is Revision 1 of the earlier report (NUREG/CR-6181). The methodology discussed in the original report is no longer current and a preferred methodology is presented in this Revision. This report, NUREG/CR-6181, Rev. 1, therefore supersedes the earlier NUREG/CR-6181 published in August 1994. The specific systems addressed in this report are the auxiliary feedwater, the low-pressure injection, and the reactor coolant systems. The results provide a risk-informed ranking of components within these systems

  6. Austenitic stainless steel weld inspection

    International Nuclear Information System (INIS)

    Mech, S.J.; Emmons, J.S.; Michaels, T.E.

    1978-01-01

    Analytical techniques applied to ultrasonic waveforms obtained from inspection of austenitic stainless steel welds are described. Experimental results obtained from a variety of geometric and defect reflectors are presented. Specifically, frequency analyses parameters, such as simple moments of the power spectrum, cross-correlation techniques, and adaptive learning network analysis, all represent improvements over conventional time domain analysis of ultrasonic waveforms. Results for each of these methods are presented, and the overall inspection difficulties of austenitic stainless steel welds are discussed

  7. Automated visual inspection of textile

    DEFF Research Database (Denmark)

    Jensen, Rune Fisker; Carstensen, Jens Michael

    1997-01-01

    A method for automated inspection of two types of textile is presented. The goal of the inspection is to determine defects in the textile. A prototype is constructed for simulating the textile production line. At the prototype the images of the textile are acquired by a high speed line scan camera...... the protype to a production line system we only need to gain a speed factor of 4....

  8. Endovascular Treatment of Phlegmasia Cerulea Dolens with Impending Venous Gangrene: Manual Aspiration Thrombectomy as the First-Line Thrombus Removal Method

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Ozkan, Ugur; Demirturk, Orhan S.; Gur, Serkan

    2011-01-01

    Purpose: Our purpose was to report the outcome of endovascular treatment with manual aspiration thrombectomy as the first-line thromboablative method for phlegmasia cerulea dolens. Methods: Between October 2006 and May 2010, seven consecutive patients (5 women, 2 men; age range, 31–80 years) with the diagnosis of phlegmasia cerulea dolens secondary to acute iliofemoral deep venous thrombosis had endovascular treatment with manual aspiration thrombectomy. Catheter-directed thrombolysis and stent placement were used as adjunctive procedures. Phlegmasia was left-sided in five and right-sided in two patients. Results: All patients had associated great saphenous vein thrombosis in addition to iliofemoral deep vein thrombosis (DVT). Aspiration thrombectomy completely removed the thrombus from the popliteal vein to the inferior vena cava (IVC) in all cases. Three patients with May-Thurner syndrome had stent placement in the left common iliac vein. Two patients had early recurrences. Repeated aspiration thrombectomy was unsuccessful in one patient. There were no complications related to the procedure. One patient who had been successfully treated died of sepsis and another patient who had unsuccessful repeated interventions had below-the-knee amputation. Overall, the clinical success and survival rates of patients in this study were 86%. On follow-up, three patients with successful treatment were asymptomatic with no deep venous insufficiency. One of these patients died during the 4-month follow-up period. Two patients had mild ankle swelling with deep venous insufficiency. Conclusions: Manual aspiration thrombectomy with adjunctive use of catheter-directed thrombolysis and stent placement is an effective endovascular treatment method with high clinical success and survival rates for phlegmasia cerulean dolens.

  9. Line-scan inspection of conifer seedlings

    Science.gov (United States)

    Rigney, Michael P.; Kranzler, Glenn A.

    1993-05-01

    Almost two billion conifer seedlings are produced in the U.S. each year to support reforestation efforts. Seedlings are graded manually to improve viability after transplanting. Manual grading is labor-intensive and subject to human variability. Our previous research demonstrated the feasibility of automated tree seedling inspection with machine vision. Here we describe a system based on line-scan imaging, providing a three-fold increase in resolution and inspection rate. A key aspect of the system is automatic recognition of the seedling root collar. Root collar diameter, shoot height, and projected shoot and root areas are measured. Sturdiness ratio and shoot/root ratio are computed. Grade is determined by comparing measured features with pre-defined set points. Seedlings are automatically sorted. The precision of machine vision and manual measurements was determined in tests at a commercial forest nursery. Manual measurements of stem diameter, shoot height, and sturdiness ratio had standard deviations three times those of machine vision measurements. Projected shoot area was highly correlated (r2 equals 0.90) with shoot volume. Projected root area had good correlation (r2 equals 0.80) with root volume. Seedlings were inspected at rates as high as ten per second.

  10. Project in fiscal 2000 of developing international standards for supporting new industries. Standardization of evaluation method for gene inspection system; 2000 nendo shinki sangyo shiengata kokusai hyojunka kaihatsu jigyo seika hokokusho. Idenshi kensa system no hyoka hoho no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Discussions and deliberations were given by the comprehensive survey committee on standardization of a total gene inspection system from specimen adjustment necessary for the gene inspection system to data processing. This paper summarizes the achievements in fiscal 2000. In standardization related to the specimen procedure and the inspection technique, the specimen storing method and the report statement contents were established. In addition, verification was made on the heat-resistant enzyme reagent and such measuring devices as the electric migration device and the photographing device. Discussions were given on standard substances used in the gene inspection. Regarding the K562 cell strain, cross-checking was performed in three institutions, wherein discussions were given on interchangeability of the inspection results, and the usefulness of the K562 cell as a standard substance. As a result, all the three institutions have come to an agreement on the Southern method, the FISH method and the RT-PCR method, but not on the real-time PT-PCR method, leaving the subject as the future assignment. In the survey for Europe and America, visits were made to AFNOR, CEN, DIN, FDA and CAP for the attempt of collecting information and establishing international exchange. (NEDO)

  11. A development of an automated ultrasonic TOFD inspection system using an welding line tracing robot

    International Nuclear Information System (INIS)

    Cho, Hyun; Song, Sung Jin; Lee, Kang Won; Kim, Young Jin; Woo, Jong Sik

    2006-01-01

    Large scaled ships, manufactured inside of the country, should be passed welding inspection and painting film inspection. Normally, these kind of inspections are conducted by human inspectors manually, although it cause industrial disasters such as falling accidents and diving accidents frequently. In addition, Ship makers are not to give a full trust to shipowners because manual inspections cannot be conducted all over the welding parts. So, in this study we developed an automated ultrasonic TOFD inspection system using an welding line tracing robot. This system, controlled by an inspector at a remote field, can inspect welding parts of ship outer panel both under water and in air. In this paper we present the developed robot and ultrasonic TOFD inspection system and the inspection result.

  12. A development of an automated ultrasonic TOFD inspection system using an welding line tracing robot

    International Nuclear Information System (INIS)

    Cho, Hyun; Song, Sung Jin; Lee, Kang Won; Kim, Young Jin; Woo, Jong Sik

    2006-01-01

    Large scaled ships, manufactured inside of the country, should be passed welding inspection and painting film inspection. Normally, these kind of inspections are conducted by human inspectors manually, although it cause industrial disasters such as falling accidents and diving accidents frequently. In addition, Ship makers are not to give a full trust to ship owners because manual inspections cannot be conducted all over the welding parts. So, in this study we developed an automated ultrasonic TOFD inspection system using an welding line tracing robot. This system, controlled by an inspector at a remote field, can inspect welding parts of ship outer panel both under water and in air. In this paper we present the developed robot and ultrasonic TOFD inspection system and the inspection result.

  13. Additive Manufacturing Infrared Inspection

    Science.gov (United States)

    Gaddy, Darrell; Nettles, Mindy

    2015-01-01

    The Additive Manufacturing Infrared Inspection Task started the development of a real-time dimensional inspection technique and digital quality record for the additive manufacturing process using infrared camera imaging and processing techniques. This project will benefit additive manufacturing by providing real-time inspection of internal geometry that is not currently possible and reduce the time and cost of additive manufactured parts with automated real-time dimensional inspections which deletes post-production inspections.

  14. Development of ultrasonic inspection technique for crack detection in retaining rings

    International Nuclear Information System (INIS)

    Brook, M.V.

    1990-01-01

    The majority of retaining rings which are currently in service, are composed of a material which is susceptible to stress corrosion when exposed to moisture. Due to the inherent stress levels in the shrunk-on areas, they are particularly susceptible to stress corrosion attack. Therefore, retaining rings require non-destructive examination to avert catastrophic failure. Guidelines for retaining ring inspection issued by EPRI recommend ultrasonic manual and automated methods of inspection for rings in place. Application of the conventional manual method, using S-waves is difficult, and yields unreliable results. Due to the unreliability factor, utilities have been forced to depend upon surface examination methods, such as visual and penetrant techniques. In most instances, a surface exam will necessitate the costly and potentially damaging removal of the rings from the rotor to provide full access to areas of interest. Due to the various complexities of conventional ultrasonic retaining ring inspections, it is essential that the front end ultrasonics (i.e., transducers and techniques) be optimized to produce the best possible examination. For this reason, AMDATA has developed custom transducers and techniques to enhance automated detection capability of flaws in the various suspect areas of retaining rings. When the optimized techniques are applied to generate the best possible raw data, the Intraspect /98 trademark is then used to reliably apply technique, acquire the data and perform post processing evaluations. One of the most promising ultrasonic techniques for retaining ring inspection is creeping waves. This paper investigates the use of creeping waves for retaining ring inspection

  15. Modelling inspection policies for building maintenance.

    Science.gov (United States)

    Christer, A H

    1982-08-01

    A method of assessing the potential of an inspection maintenance policy as opposed to an existing breakdown maintenance policy for a building complex is developed. The method is based upon information likely to be available and specific subjective assessments which could be made available. Estimates of the expected number of defects identified at an inspection and the consequential cost saving are presented as functions of the inspection frequency.

  16. Standard Practice for Installation, Inspection, and Maintenance of Valve-body Pressure-relief Methods for Geothermal and Other High-Temperature Liquid Applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This practice covers installation, inspection, and maintenance of valve body cavity pressure relief methods for valves used in geothermal and other high-temperature liquid service. The valve type covered by this practice is a design with an isolated body cavity such that when the valve is in either the open or closed position pressure is trapped in the isolated cavity, and there is no provision to relieve the excess pressure internally. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. Waste Inspection Tomography (WIT)

    International Nuclear Information System (INIS)

    Bernardi, R.T.

    1995-01-01

    Waste Inspection Tomography (WIT) provides mobile semi-trailer mounted nondestructive examination (NDE) and assay (NDA) for nuclear waste drum characterization. WIT uses various computed tomography (CT) methods for both NDE and NDA of nuclear waste drums. Low level waste (LLW), transuranic (TRU), and mixed radioactive waste can be inspected and characterized without opening the drums. With externally transmitted x-ray NDE techniques, WIT has the ability to identify high density waste materials like heavy metals, define drum contents in two- and three-dimensional space, quantify free liquid volumes through density and x-ray attenuation coefficient discrimination, and measure drum wall thickness. With waste emitting gamma-ray NDA techniques, WIT can locate gamma emitting radioactive sources in two- and three-dimensional space, identify gamma emitting isotopic species, identify the external activity levels of emitting gamma-ray sources, correct for waste matrix attenuation, provide internal activity approximations, and provide the data needed for waste classification as LLW or TRU. The mobile feature of WIT allows inspection technologies to be brought to the nuclear waste drum storage site without the need to relocate drums for safe, rapid, and cost-effective characterization of regulated nuclear waste. The combination of these WIT characterization modalities provides the inspector with an unprecedented ability to non-invasively characterize the regulated contents of waste drums as large as 110 gallons, weighing up to 1,600 pounds. Any objects that fit within these size and weight restrictions can also be inspected on WIT, such as smaller waste bags and drums that are five and thirty-five gallons

  18. Pdap Manual

    DEFF Research Database (Denmark)

    Pedersen, Mads Mølgaard; Larsen, Torben J.

    Pdap, Python Data Analysis Program, is a program for post processing, analysis, visualization and presentation of data e.g. simulation results and measurements. It is intended but not limited to the domain of wind turbines. It combines an intuitive graphical user interface with python scripting...... that allows automation and implementation of custom functions. This manual gives a short introduction to the graphical user interface, describes the mathematical background for some of the functions, describes the scripting API and finally a few examples on how automate analysis via scripting is presented....... The newest version, and more documentation and help on how to used, extend and automate Pdap can be found at the webpage www.hawc2.dk...

  19. Longitudinal wave ultrasonic inspection of austenitic weldments

    International Nuclear Information System (INIS)

    Gray, B.S.; Hudgell, R.J.; Seed, H.

    1980-01-01

    Successful volumetric inspection of LMFBR primary circuits, and also much of the secondary circuit, is dependent on the availability of satisfactory examination procedures for austenitic welds. Application of conventional ultrasonic techniques is hampered by the anisotropic, textured structure of the weld metal and this paper describes development work on the use of longitudinal wave techniques. In addition to confirming the dominant effects of the weld structure on ultrasound propagation some results are given of studies utilising deliberately induced defects in Manual Metal Arc Welds in 50 mm plate together with preliminary work on the inspection of narrow austenitic welds fabricated by automatic processes. (author)

  20. US Department of Energy Radiological Control Manual

    International Nuclear Information System (INIS)

    1992-06-01

    This manual establishes practices for the conduct of radiological control activities. The Manual states DOE's positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. (VC)

  1. AUTOMATED INSPECTION OF POWER LINE CORRIDORS TO MEASURE VEGETATION UNDERCUT USING UAV-BASED IMAGES

    Directory of Open Access Journals (Sweden)

    M. Maurer

    2017-08-01

    Full Text Available Power line corridor inspection is a time consuming task that is performed mostly manually. As the development of UAVs made huge progress in recent years, and photogrammetric computer vision systems became well established, it is time to further automate inspection tasks. In this paper we present an automated processing pipeline to inspect vegetation undercuts of power line corridors. For this, the area of inspection is reconstructed, geo-referenced, semantically segmented and inter class distance measurements are calculated. The presented pipeline performs an automated selection of the proper 3D reconstruction method for on the one hand wiry (power line, and on the other hand solid objects (surrounding. The automated selection is realized by performing pixel-wise semantic segmentation of the input images using a Fully Convolutional Neural Network. Due to the geo-referenced semantic 3D reconstructions a documentation of areas where maintenance work has to be performed is inherently included in the distance measurements and can be extracted easily. We evaluate the influence of the semantic segmentation according to the 3D reconstruction and show that the automated semantic separation in wiry and dense objects of the 3D reconstruction routine improves the quality of the vegetation undercut inspection. We show the generalization of the semantic segmentation to datasets acquired using different acquisition routines and to varied seasons in time.

  2. Automated Inspection of Power Line Corridors to Measure Vegetation Undercut Using Uav-Based Images

    Science.gov (United States)

    Maurer, M.; Hofer, M.; Fraundorfer, F.; Bischof, H.

    2017-08-01

    Power line corridor inspection is a time consuming task that is performed mostly manually. As the development of UAVs made huge progress in recent years, and photogrammetric computer vision systems became well established, it is time to further automate inspection tasks. In this paper we present an automated processing pipeline to inspect vegetation undercuts of power line corridors. For this, the area of inspection is reconstructed, geo-referenced, semantically segmented and inter class distance measurements are calculated. The presented pipeline performs an automated selection of the proper 3D reconstruction method for on the one hand wiry (power line), and on the other hand solid objects (surrounding). The automated selection is realized by performing pixel-wise semantic segmentation of the input images using a Fully Convolutional Neural Network. Due to the geo-referenced semantic 3D reconstructions a documentation of areas where maintenance work has to be performed is inherently included in the distance measurements and can be extracted easily. We evaluate the influence of the semantic segmentation according to the 3D reconstruction and show that the automated semantic separation in wiry and dense objects of the 3D reconstruction routine improves the quality of the vegetation undercut inspection. We show the generalization of the semantic segmentation to datasets acquired using different acquisition routines and to varied seasons in time.

  3. Comparison of manual tracing versus a semiautomatic radial measurement method in temporal lobe MRI volumetry for pharmacoresistant epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Christian-Andreas; Scorzin, Jasmin; Schramm, Johannes [University of Bonn, Department of Neurosurgery, Bonn (Germany); Koenig, Roy; Urbach, Horst [University of Bonn, Department of Radiology Neuroradiology, Bonn (Germany); Fimmers, Rolf [University of Bonn, Institute of Medical Biometry, Informatics and Epidemiology, Bonn (Germany); Zentner, Josef [University of Freiburg, Department of Neurosurgery, Freiburg (Germany); Lehmann, Thomas-Nicolas [Charite-University Medicine Berlin, Department of Neurosurgery, Berlin (Germany)

    2007-03-15

    The aim of this study was to test a modified radial semiautomated volumetry technique (radial divider technique, RDT) versus the manual volumetry technique (MVT) for proportionality of temporal subvolumes in 30 patients with drug-resistant temporal lobe epilepsy. Included in the study were 30 patients (15 female, 15 male; mean age 39.6 years) with pharmacoresistant epilepsy (mean duration 26.6 years). MRI studies were performed preoperatively on a 1.5-T scanner. All image processing steps and volume measurements were performed using ANALYZE software. The volumes of six subregions were measured bilaterally; these included the superior temporal gyrus (STG), middle + inferior temporal gyrus (MITG), fusiform gyrus (FG), parahippocampal gyrus (PHG), amygdala (AM), and hippocampus (HP). Linear regression was used to investigate the relationship between the comparable subvolumes obtained with MVT and RDT. Very high correlations (R {sup 2} >0.95) between RDT and MVT were observed for the STG + MITG and the STG + MITG + FG, but low correlations for the PHG subvolumes and the combined PHG + HP + AM subvolumes. These observations were independent of the side of the pathology and of hemisphere. The two measurement techniques provided highly reliable proportional results. This series in a homogeneous group of TLE patients suggests that the much quicker RDT is suitable for determining the volume of temporolateral and laterobasal temporal lobe compartments, of both the affected and the non-affected side and the right and left hemisphere. (orig.)

  4. Comparison of manual tracing versus a semiautomatic radial measurement method in temporal lobe MRI volumetry for pharmacoresistant epilepsy

    International Nuclear Information System (INIS)

    Mueller, Christian-Andreas; Scorzin, Jasmin; Schramm, Johannes; Koenig, Roy; Urbach, Horst; Fimmers, Rolf; Zentner, Josef; Lehmann, Thomas-Nicolas

    2007-01-01

    The aim of this study was to test a modified radial semiautomated volumetry technique (radial divider technique, RDT) versus the manual volumetry technique (MVT) for proportionality of temporal subvolumes in 30 patients with drug-resistant temporal lobe epilepsy. Included in the study were 30 patients (15 female, 15 male; mean age 39.6 years) with pharmacoresistant epilepsy (mean duration 26.6 years). MRI studies were performed preoperatively on a 1.5-T scanner. All image processing steps and volume measurements were performed using ANALYZE software. The volumes of six subregions were measured bilaterally; these included the superior temporal gyrus (STG), middle + inferior temporal gyrus (MITG), fusiform gyrus (FG), parahippocampal gyrus (PHG), amygdala (AM), and hippocampus (HP). Linear regression was used to investigate the relationship between the comparable subvolumes obtained with MVT and RDT. Very high correlations (R 2 >0.95) between RDT and MVT were observed for the STG + MITG and the STG + MITG + FG, but low correlations for the PHG subvolumes and the combined PHG + HP + AM subvolumes. These observations were independent of the side of the pathology and of hemisphere. The two measurement techniques provided highly reliable proportional results. This series in a homogeneous group of TLE patients suggests that the much quicker RDT is suitable for determining the volume of temporolateral and laterobasal temporal lobe compartments, of both the affected and the non-affected side and the right and left hemisphere. (orig.)

  5. Vision based tunnel inspection using non-rigid registration

    Science.gov (United States)

    Badshah, Amir; Ullah, Shan; Shahzad, Danish

    2015-04-01

    Growing numbers of long tunnels across the globe has increased the need for safety measurements and inspections of tunnels in these days. To avoid serious damages, tunnel inspection is highly recommended at regular intervals of time to find any deformations or cracks at the right time. While following the stringent safety and tunnel accessibility standards, conventional geodetic surveying using techniques of civil engineering and other manual and mechanical methods are time consuming and results in troublesome of routine life. An automatic tunnel inspection by image processing techniques using non rigid registration has been proposed. There are many other image processing methods used for image registration purposes. Most of the processes are operation of images in its spatial domain like finding edges and corners by Harris edge detection method. These methods are quite time consuming and fail for some or other reasons like for blurred or images with noise. Due to use of image features directly by these methods in the process, are known by the group, correlation by image features. The other method is featureless correlation, in which the images are converted into its frequency domain and then correlated with each other. The shift in spatial domain is the same as in frequency domain, but the processing is order faster than in spatial domain. In the proposed method modified normalized phase correlation has been used to find any shift between two images. As pre pre-processing the tunnel images i.e. reference and template are divided into small patches. All these relative patches are registered by the proposed modified normalized phase correlation. By the application of the proposed algorithm we get the pixel movement of the images. And then these pixels shifts are converted to measuring units like mm, cm etc. After the complete process if there is any shift in the tunnel at described points are located.

  6. Study to define NDE research for inspection of stainless steels

    International Nuclear Information System (INIS)

    Reinhart, E.R.

    1978-08-01

    After the boiling water reactor (BWR) stress corrosion cracking incidents on 4- and 10-inch stainless steel piping, the Electric Power Research Institute (EPRI) organized a round-robin ultrasonic examination of piping removed from service (TPS-75-609). Five inspection teams participated in this program, using both a standard procedure and the individual team procedure. The original intent was to section the piping after the program to evaluate the effectiveness of state-of-the-art ultrasonics in finding stress corrosion cracking. The sectioning was delayed, however, to allow research and development (R and D) groups time to perform basic measurements aimed at determining optimum search unit and instrument characteristics for the ultrasonic examination of stainless steel piping and to study the applicability of various advanced inspection methods. This additional effort was funded as part of an EPRI technical planning study (TPS-75-620), A Study to Define NDE Research for Inspection of Stainless Steels. Inspection methods evaluated in this study included (1) processing of manual scan data using a miniature programmable calculator (Aerojet Nuclear); (2) investigation into the performance characteristics of three experimental ultrasonic transducers (Battelle-Columbus Laboratories); (3) analysis of fundamental ultrasonic response data from intergranular stress corrosion cracks in stainless steels (Southwest Research Institute); and (4) a feasibility study of advanced signal processing and pattern recognition for analyzing flaws in stainless steel piping (Ultrasonics International). The results of the studies compiled in the report have indicated the direction for future research and development and have formed the basis for the recently initiated EPRI Research Project 892, Ultrasonic System Optimization

  7. Caltrans : construction manual

    Science.gov (United States)

    2009-08-01

    Caltrans intends this manual as a resource for all personnel engaged in contract administration. The manual establishes policies and procedures for the construction phase of Caltrans projects. However, this manual is not a contract document. It impos...

  8. A New Method for Treatment of Lymphedema of Limbs: Standardized Manual Massage with a New Device Linforoll in Conservative and Surgical Therapy Protocols.

    Science.gov (United States)

    Olszewski, Waldemar L; Zaleska, Marzanna; Michelin, Sandro

    2016-12-01

    Edema fluid in lymphedematous limbs should be evacuated to sites where it can be absorbed. It should be moved either to the hypogastrium or arm/scapular regions along tissue channels or implanted silicon channels or through lymphovenous anastomoses. For that purpose, the manual lymphatic drainage of limb is an effective method. Standardization of manual massage applied force and timing becomes necessary. A device with known pressing area and continuously showing the applied force while moving it toward the root of the limb is needed. Moreover, force could be adjusted to the stiffness of the massaged tissues that varies at different levels of the limb. Results from such a device would be repeatable and reproducible by others. In this study we present data on tissue fluid hydromechanics obtained from 20 patients with obstructive limb lymphedema during massage with a massaging roller called Linforoll. Linforoll is composed of a hand piece with roller and pressure sensor connected wireless to the computer displaying the pressure curve of the applied force. Electron microscopy studies for checking eventual tissue changes were done. Linforoll provides the possibilities of: 1) regulating the applied force according to the hydromechanic conditions of the massaged tissues; 2) standardization of massage repeatable in the same patient; 3) decrease of limb volume; 4) evident increase in tissue elasticity; 5) application as a driving force for fluid flow along the surgically implanted tubing and vessels running to the lymphovenous shunts.

  9. Nuclear power plant pressure vessels. Inservice inspections

    International Nuclear Information System (INIS)

    1995-01-01

    The requirements for the planning and reporting of inservice inspections of nuclear power plant pressure vessels are presented. The guide specifically applies to inservice inspections of Safety class 1 and 2 nuclear power plant pressure vessels, piping, pumps and valves plus their supports and reactor pressure vessel internals by non- destructive examination methods (NDE). Inservice inspections according to the Pressure Vessel Degree (549/73) are discussed separately in the guide YVL 3.0. (4 refs.)

  10. Periodic inspections of the primary system

    International Nuclear Information System (INIS)

    Dufour, L.B.

    1978-01-01

    An impression is given of the inspection techniques, preparations and background for periodic examinations of the primary system of the Dodewaard Nuclear Reactor over the past 10 years. Unfortunately reliable integral inspection techniques to enable 'listening-in' to developing faults, are not yet available. Until they are, inspections will continue to be executed from a distance using different continuous methods, often under water and with a shortage of space and in the presence of ionising radiations. (C.F.)

  11. Plant equipment integrity monitoring and diagnosing method and device therefor, plant equipment maintenance and inspection time determining method and device therefor, as well as nuclear power plant

    International Nuclear Information System (INIS)

    Kato, Takahiko; Ando, Masashi; Osumi, Katsumi; Horiuchi, Tetsuo; Asakura, Yamato; Akamine, Kazuhiko.

    1995-01-01

    The present invention can accurately forecast a time for occurrence of troubles of plant equipments in contact with recycling water, to conduct its maintenance and inspection before occurrence of the troubles. Namely, change of water quality in plant equipments caused by corrosion of recycling water occurred in constitutional parts of the plant equipments is measured. The time upon occurrence of the troubles of the plant equipments to corrosion of the recycling water is forecast based on the measured value. A time till the occurrence of the change of water quality after starting the use of the plant equipments is calculated based on the measured value. The calculated time is compared with a correlation between the time of occurrence of the troubles after starting the use of the plant equipments and the time of occurrence of change of the water quality, to forecast the time of occurrence of the troubles. Preferably, electroconductivity and pH of recycling water in the inside or at the exit of the plant equipments are measured as an object for the measurement of change of water quality. (I.S.)

  12. Comprehensive field evaluation of asphalt patching methods and development of simple decision trees and a best practices manual.

    Science.gov (United States)

    2017-06-01

    The long-term performance of pothole patches largely depends on the selection of the patching method. A number of pothole patching methods are in practice in Minnesota and other nearby states. However, pavement maintenance crews often encounter probl...

  13. Automated Inspection of Aircraft

    Science.gov (United States)

    1998-04-01

    This report summarizes the development of a robotic system designed to assist aircraft inspectors by remotely deploying non-destructive inspection (NDI) sensors and acquiring, processing, and storing inspection data. Carnegie Mellon University studie...

  14. Optimising import phytosanitary inspection

    NARCIS (Netherlands)

    Surkov, I.

    2007-01-01

    Keywords: quarantine pest, plant health policy, optimization, import phytosanitary inspection, ‘reduced checks’, optimal allocation of resources, multinomial logistic regression, the Netherlands World trade is a major vector of spread of quarantine plant pests. Border phytosanitary inspection

  15. Development of a remote inspection robot for high pressure structures

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae C.; Kim, Jae H.; Choi, Yu R.; Moon, Soon S

    1999-10-01

    The high pressure structures in industrial plants must be periodically inspected for ensure their safety. Currently, the examination of them is manually performed by human inspectors, and there are many restrictions to examine the large containers which enclose dangerous chemicals or radioactive materials. We developed a remotely operated robot to examine these structures using recent mobile robot and computer technologies. Our robot has two magnetic caterpillars that make the robot can adhere to the structures made of steel like materials. The robot moves to the position for examination, and scans that position using ultrasonic probes equipped on it's arm, and transmits the result to the inspector according to his/her commands. Without building any auxiliary structures the robot can inspect the places where manual inspection can't reach. Therefore the robot can make shortening the inspection time as well as preventing the inspector from an accident. (author)

  16. Development of a remote inspection robot for high pressure structures

    International Nuclear Information System (INIS)

    Lee, Jae C.; Kim, Jae H.; Choi, Yu R.; Moon, Soon S.

    1999-10-01

    The high pressure structures in industrial plants must be periodically inspected for ensure their safety. Currently, the examination of them is manually performed by human inspectors, and there are many restrictions to examine the large containers which enclose dangerous chemicals or radioactive materials. We developed a remotely operated robot to examine these structures using recent mobile robot and computer technologies. Our robot has two magnetic caterpillars that make the robot can adhere to the structures made of steel like materials. The robot moves to the position for examination, and scans that position using ultrasonic probes equipped on it's arm, and transmits the result to the inspector according to his/her commands. Without building any auxiliary structures the robot can inspect the places where manual inspection can't reach. Therefore the robot can make shortening the inspection time as well as preventing the inspector from an accident. (author)

  17. Comparison of manual mycobacteria growth indicator tube and epsilometer test with agar proportion method for susceptibility testing of Mycobacterium tuberculosis

    Directory of Open Access Journals (Sweden)

    N Karabulut

    2014-01-01

    Full Text Available Background and Objectives: Antimycobacterial susceptibility tests take weeks, and delayed therapy can lead to spread of Mycobacterium tuberculosis. Therefore, rapid, accurate and cost-effective methods are required for proper therapy selection. In this study, the Mycobacteria growth indicator tube (MGIT and epsilometer test (Etest methods were compared to the agar proportion method for susceptibility testing of Mycobacterium tuberculosis. Materials and Methods: The susceptibility tests against isoniazid (INH, rifampin (RIF, streptomycin (STM and ethambutol (ETM of 51 M. tuberculosis complex isolates were analyzed by the MGIT, Etest and agar proportion methods. Results: The concordance between MGIT/Etest and agar proportion methods was 98% for INH and 100% for RIF, STM, ETM. There were not statistically significant differences in results of the susceptibility tests between MGIT/Etest and the reference agar proportion method. Conclusion: The results have shown that MGIT and Etest methods can be used instead of the agar proportion method, because these two methods are more rapid and easier than the agar proportion method.

  18. Development of a novel non-contact inspection technique to detect micro cracks under the surface of a glass substrate by thermal stress-induced light scattering method

    Science.gov (United States)

    Sakata, Yoshitaro; Terasaki, Nao; Nonaka, Kazuhiro

    2017-05-01

    Fine polishing techniques, such as a chemical mechanical polishing treatment, are important techniques in glass substrate manufacturing. However, these techniques may cause micro cracks under the surface of glass substrates because they used mechanical friction. A stress-induced light scattering method (SILSM), which was combined with light scattering method and mechanical stress effects, was proposed for inspecting surfaces to detect polishing-induced micro cracks. However, in the conventional SILSM, samples need to be loaded with physical contact, and the loading point is invisible in transparent materials. Here, we introduced a novel non-contact SILSM using a heating device. A glass substrate was heated first, and then the light scattering intensity of micro cracks was detected by a cooled charge-couple device camera during the natural cooling process. Results clearly showed during the decreasing surface temperature of a glass substrate, appropriate thermal stress is generated for detecting micro cracks by using the SILSM and light scattering intensity from micro cracks changes. We confirmed that non-contact thermal SILSM (T-SILSM) can detect micro cracks under the surface of transparent materials.

  19. Technical objectives of inspection

    International Nuclear Information System (INIS)

    Sorenson, R.J.; Stewart, K.B.; Schneider, R.A.

    1976-01-01

    The various technical objectives of inspection are discussed in a very general manner. The discussion includes how the inspection function is related to the assumed threat, the various degrees of assurance and reliance on criteria, and the hierarchy of assurance which is obtained from the various types or levels of inspection

  20. Remotely deployable aerial inspection using tactile sensors

    Science.gov (United States)

    MacLeod, C. N.; Cao, J.; Pierce, S. G.; Sullivan, J. C.; Pipe, A. G.; Dobie, G.; Summan, R.

    2014-02-01

    For structural monitoring applications, the use of remotely deployable Non-Destructive Evaluation (NDE) inspection platforms offer many advantages, including improved accessibility, greater safety and reduced cost, when compared to traditional manual inspection techniques. The use of such platforms, previously reported by researchers at the University Strathclyde facilitates the potential for rapid scanning of large areas and volumes in hazardous locations. A common problem for both manual and remote deployment approaches lies in the intrinsic stand-off and surface coupling issues of typical NDE probes. The associated complications of these requirements are obviously significantly exacerbated when considering aerial based remote inspection and deployment, resulting in simple visual techniques being the preferred sensor payload. Researchers at Bristol Robotics Laboratory have developed biomimetic tactile sensors modelled on the facial whiskers (vibrissae) of animals such as rats and mice, with the latest sensors actively sweeping their tips across the surface in a back and forth motion. The current work reports on the design and performance of an aerial inspection platform and the suitability of tactile whisking sensors to aerial based surface monitoring applications.

  1. Factors controlling headspace pressure in a manual manometric BMP method can be used to produce a methane output comparable to AMPTS.

    Science.gov (United States)

    Himanshu, H; Voelklein, M A; Murphy, J D; Grant, J; O'Kiely, P

    2017-08-01

    The manual manometric biochemical methane potential (mBMP) test uses the increase in pressure to calculate the gas produced. This gas production may be affected by the headspace volume in the incubation bottle and by the overhead pressure measurement and release (OHPMR) frequency. The biogas and methane yields of cellulose, barley, silage and slurry were compared with three incubation bottle headspace volumes (50, 90 and 180ml; constant 70ml total medium) and four OHPMR frequencies (daily, each third day, weekly and solely at the end of experiment). The methane yields of barley, silage and slurry were compared with those from an automated volumetric method (AMPTS). Headspace volume and OHPMR frequency effects on biogas yield were mediated mainly through headspace pressure, with the latter having a negative effect on the biogas yield measured and relatively little effect on methane yield. Two mBMP treatments produced methane yields equivalent to AMPTS. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. X-ray inspection of foreign bodies in foods

    International Nuclear Information System (INIS)

    Ohira, Norihiro; Hongjun, Zhou; Sakamaki, Kazumi; Kamimura, Kunio; Shimizu, Hideaki; Saiki, Hideo

    2008-01-01

    X-ray inspection system of foreign bodies in foods has become is necessary for our society in recent years, with the expectation that they could inspect not only metals but also other bodies like glass, rubber, nylon, etc. Calculation algorithms for X-ray inspection of foreign bodies in foods have been reported. In food inspection systems, it is important that inspection is high precision, with high speed that is as fast as conveyor belts. Using Statistical methods, we construct a higher precision method than usual methods. We focused on Kittler's minimum error thresholding. In the usual Kittler's method, order n-squared calculations are required for distributed calculation, so it is not suitable for high speed food inspection. We find that using approximations of variances in Kittler's method is not too critical for practical use. Using it, we be come able to inspect for foreign bodies that were not able to be inspected for so far. (author)

  3. EPA Method 3135.2I: Cyanide, Total and Amenable in Aqueous and Solid Samples Automated Colorimetric With Manual Digestion

    Science.gov (United States)

    This method describes procedures for preparation and analysis of solid, water and wipe samples for detection and measurement of cyanide amendable to chlorination using acid digestion and spectrophotometry.

  4. Optimizing the design of international safeguards inspection systems

    International Nuclear Information System (INIS)

    Markin, J.T.; Coulter, C.A.; Gutmacher, R.G.; Whitty, W.J.

    1983-01-01

    Efficient implementation of international inspections for verifying the operation of a nuclear facility requires that available resources be allocated among inspection activities to maximize detection of misoperation. This report describes a design and evaluation method for selecting an inspection system that is optimal for accomplishing inspection objectives. The discussion includes methods for identifying system objectives, defining performance measures, and choosing between candidate systems. Optimization theory is applied in selecting the most preferred inspection design for a single nuclear facility, and an extension to optimal allocation of inspection resources among States containing multiple facilities is outlined. 3 figures, 5 tables

  5. Computer automation of ultrasonic testing. [inspection of ultrasonic welding

    Science.gov (United States)

    Yee, B. G. W.; Kerlin, E. E.; Gardner, A. H.; Dunmyer, D.; Wells, T. G.; Robinson, A. R.; Kunselman, J. S.; Walker, T. C.

    1974-01-01

    Report describes a prototype computer-automated ultrasonic system developed for the inspection of weldments. This system can be operated in three modes: manual, automatic, and computer-controlled. In the computer-controlled mode, the system will automatically acquire, process, analyze, store, and display ultrasonic inspection data in real-time. Flaw size (in cross-section), location (depth), and type (porosity-like or crack-like) can be automatically discerned and displayed. The results and pertinent parameters are recorded.

  6. Automated extraction of DNA from biological stains on fabric from crime cases. A comparison of a manual and three automated methods.

    Science.gov (United States)

    Stangegaard, Michael; Hjort, Benjamin B; Hansen, Thomas N; Hoflund, Anders; Mogensen, Helle S; Hansen, Anders J; Morling, Niels

    2013-05-01

    The presence of PCR inhibitors in extracted DNA may interfere with the subsequent quantification and short tandem repeat (STR) reactions used in forensic genetic DNA typing. DNA extraction from fabric for forensic genetic purposes may be challenging due to the occasional presence of PCR inhibitors that may be co-extracted with the DNA. Using 120 forensic trace evidence samples consisting of various types of fabric, we compared three automated DNA extraction methods based on magnetic beads (PrepFiler Express Forensic DNA Extraction Kit on an AutoMate Express, QIAsyphony DNA Investigator kit either with the sample pre-treatment recommended by Qiagen or an in-house optimized sample pre-treatment on a QIAsymphony SP) and one manual method (Chelex) with the aim of reducing the amount of PCR inhibitors in the DNA extracts and increasing the proportion of reportable STR-profiles. A total of 480 samples were processed. The highest DNA recovery was obtained with the PrepFiler Express kit on an AutoMate Express while the lowest DNA recovery was obtained using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen. Extraction using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen resulted in the lowest percentage of PCR inhibition (0%) while extraction using manual Chelex resulted in the highest percentage of PCR inhibition (51%). The largest number of reportable STR-profiles was obtained with DNA from samples extracted with the PrepFiler Express kit (75%) while the lowest number was obtained with DNA from samples extracted using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen (41%). Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. Validated automated ultrasonic inspections of the Sizewell 'B' reactor pressure vessel

    International Nuclear Information System (INIS)

    Dikstra, B.J.; Farley, J.M.

    1992-01-01

    Automated ultrasonic inspection was applied extensively during manufacture of the RPV for Sizewell 'B'. This was an important element of the safety case presented at the Sizewell 'B' public enquiry. This requirement reflected concern in the United Kingdom as to the effectiveness and reliability of ultrasonic inspections. By applying automated inspections in addition to the manual ultrasonic inspection carried out by the vessel manufacturer, the overall reliability of the inspection of the vessel would be considerably enhanced. The automated inspections carried out in the manufacturer's workshops were termed 'automated shop inspections' (ASIs). The ASIs were carried out in two contracts: the first to inspect the component forgings of the RPV, the second to inspect the pressure retaining welds. (author)

  8. How Agencies Inspect. A Comparative Study of Inspection Policies in Eight Swedish Government Agencies

    International Nuclear Information System (INIS)

    Lindblom, Lars; Clausen, Jonas; Edvardsson, Karin; Hayenhielm, Madeleine; Hermansson, Helene; Nihlen, Jessica; Palm, Elin; Ruden, Christina; Wikman, Per; Hansson, Sven Ove

    2003-04-01

    Eight Swedish authorities with inspection tasks in the areas of health, safety, and environmental protection have been compared, namely the authorities responsible for nuclear safety, radiation protection, railway, marine and aviation safety, environmental protection, chemicals control, and health and safety on workplaces. Significant differences in inspection policies and practices between the authorities were found, such as: diverging definitions of supervision and inspection that complicate comparisons, different priority-setting principles for inspections, variations in inspection frequencies (between 13 and 0.03 inspections per company and year), different practices with respect to notifying companies before inspection visits, and in particular, large differences in the extent to which non-compliance with regulations is reported to legal authorities. It was concluded that these agencies have much to gain from increasing their cooperation in methods development, evaluation studies, and education of inspectors

  9. Randomization of inspections

    International Nuclear Information System (INIS)

    Markin, J.T.

    1989-01-01

    As the numbers and complexity of nuclear facilities increase, limitations on resources for international safeguards may restrict attainment of safeguards goals. One option for improving the efficiency of limited resources is to expand the current inspection regime to include random allocation of the amount and frequency of inspection effort to material strata or to facilities. This paper identifies the changes in safeguards policy, administrative procedures, and operational procedures that would be necessary to accommodate randomized inspections and identifies those situations where randomization can improve inspection efficiency and those situations where the current nonrandom inspections should be maintained. 9 refs., 1 tab

  10. Review of progress in magnetic particle inspection

    Science.gov (United States)

    Eisenmann, David J.; Enyart, Darrel; Lo, Chester; Brasche, Lisa

    2014-02-01

    Magnetic particle inspection (MPI) has been widely utilized for decades, and sees considerable use in the aerospace industry with a majority of the steel parts being inspected with MPI at some point in the lifecycle. Typical aircraft locations inspected are landing gear, engine components, attachment hardware, and doors. In spite of its numerous applications the method remains poorly understood, and there are many aspects of that method which would benefit from in-depth study. This shortcoming is due to the fact that MPI combines the complicated nature of electromagnetics, metallurgical material effects, fluid-particle motion dynamics, and physiological human factors into a single inspection. To promote understanding of the intricate method issues that affect sensitivity, or to assist with the revision of industry specifications and standards, research studies will be prioritized through the guidance of a panel of industry experts, using an approach which has worked successfully in the past to guide fluorescent penetrant inspection (FPI) research efforts.

  11. On automatic visual inspection of reflective surfaces

    DEFF Research Database (Denmark)

    Kulmann, Lionel

    1995-01-01

    surfaces, providing new and exciting applications subject to automated visual inspection. Several contextual features have been surveyed along with introduction of novel methods to perform data-dependent enhancement of local surface appearance . Morphological methods have been described and utilized......This thesis descrbes different methods to perform automatic visual inspection of reflective manufactured products, with the aim of increasing productivity, reduce cost and improve the quality level of the production. We investigate two different systems performing automatic visual inspection....... The first is the inspection of highly reflective aluminum sheets, used by the Danish company Bang & Olufsen, as a part of the exterior design and general appearance of their audio and video products. The second is the inspection of IBM hard disk read/write heads for defects during manufacturing. We have...

  12. Enumeration of CD4 and CD8 T-cells in HIV infection in Zimbabwe using a manual immunocytochemical method

    DEFF Research Database (Denmark)

    Gomo, E; Ndhlovu, P; Vennervald, B J

    2001-01-01

    OBJECTIVES: To enumerate CD4 and CD8 T-cells using the simple and cheap immuno-alkaline phosphatase (IA) method and to compare it with flow cytometry (FC); and to study the effects of duration of sample storage on the IA method results. DESIGN: Method comparison study. SETTING: Blair Research...... Laboratory, Harare, Zimbabwe. SUBJECTS: 41 HIV positive and 11 HIV negative men and women from Harare participating in HIV studies at Blair Research Laboratory, Zimbabwe. MAIN OUTCOME MEASURES: CD4 and CD8 T-cell counts by FC and the IA method. RESULTS: The IA method and FC were highly correlated for CD4...... counts (Spearman rs = 0.91), CD4 percentage (rs = 0.84), CD8 count (rs = 0.83), CD8 percentage (rs = 0.96) and CD4/CD8 ratio (rs = 0.89). However, CD4 cell counts and percentage measured by the IA method were (mean difference +/- SE) 133 +/- 24 cells/microL [corrected] and 6.7 +/- 1.1% higher than those...

  13. Risk Based Inspection Planning of Ageing Structures

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Ersdal, Gerhard

    2008-01-01

    . Different approaches for updating inspection plans for older installations are considered in order to achieve decreased inspection intervals as the structure are ageing. The most promising method consists in increasing the rate of defects / crack initiation at the end of the expected lifetime. Different...

  14. Waste inspection tomography (WIT)

    Energy Technology Data Exchange (ETDEWEB)

    Bernardi, R.T. [Bio-Imaging Research, Inc., Lincolnshire, IL (United States)

    1995-10-01

    Waste Inspection Tomography (WIT) provides mobile semi-trailer mounted nondestructive examination (NDE) and assay (NDA) for nuclear waste drum characterization. WIT uses various computed tomography (CT) methods for both NDE and NDA of nuclear waste drums. Low level waste (LLW), transuranic (TRU), and mixed radioactive waste can be inspected and characterized without opening the drums. With externally transmitted x-ray NDE techniques, WIT has the ability to identify high density waste materials like heavy metals, define drum contents in two- and three-dimensional space, quantify free liquid volumes through density and x-ray attenuation coefficient discrimination, and measure drum wall thickness. With waste emitting gamma-ray NDA techniques, WIT can locate gamma emitting radioactive sources in two- and three-dimensional space, identify gamma emitting, isotopic species, identify the external activity levels of emitting gamma-ray sources, correct for waste matrix attenuation, provide internal activity approximations, and provide the data needed for waste classification as LLW or TRU.

  15. Waste inspection tomography (WIT)

    International Nuclear Information System (INIS)

    Bernardi, R.T.

    1995-01-01

    Waste Inspection Tomography (WIT) provides mobile semi-trailer mounted nondestructive examination (NDE) and assay (NDA) for nuclear waste drum characterization. WIT uses various computed tomography (CT) methods for both NDE and NDA of nuclear waste drums. Low level waste (LLW), transuranic (TRU), and mixed radioactive waste can be inspected and characterized without opening the drums. With externally transmitted x-ray NDE techniques, WIT has the ability to identify high density waste materials like heavy metals, define drum contents in two- and three-dimensional space, quantify free liquid volumes through density and x-ray attenuation coefficient discrimination, and measure drum wall thickness. With waste emitting gamma-ray NDA techniques, WIT can locate gamma emitting radioactive sources in two- and three-dimensional space, identify gamma emitting, isotopic species, identify the external activity levels of emitting gamma-ray sources, correct for waste matrix attenuation, provide internal activity approximations, and provide the data needed for waste classification as LLW or TRU

  16. EMG normalization method based on grade 3 of manual muscle testing: Within- and between-day reliability of normalization tasks and application to gait analysis.

    Science.gov (United States)

    Tabard-Fougère, Anne; Rose-Dulcina, Kevin; Pittet, Vincent; Dayer, Romain; Vuillerme, Nicolas; Armand, Stéphane

    2018-02-01

    Electromyography (EMG) is an important parameter in Clinical Gait Analysis (CGA), and is generally interpreted with timing of activation. EMG amplitude comparisons between individuals, muscles or days need normalization. There is no consensus on existing methods. The gold standard, maximum voluntary isometric contraction (MVIC), is not adapted to pathological populations because patients are often unable to perform an MVIC. The normalization method inspired by the isometric grade 3 of manual muscle testing (isoMMT3), which is the ability of a muscle to maintain a position against gravity, could be an interesting alternative. The aim of this study was to evaluate the within- and between-day reliability of the isoMMT3 EMG normalizing method during gait compared with the conventional MVIC method. Lower limb muscles EMG (gluteus medius, rectus femoris, tibialis anterior, semitendinosus) were recorded bilaterally in nine healthy participants (five males, aged 29.7±6.2years, BMI 22.7±3.3kgm -2 ) giving a total of 18 independent legs. Three repeated measurements of the isoMMT3 and MVIC exercises were performed with an EMG recording. EMG amplitude of the muscles during gait was normalized by these two methods. This protocol was repeated one week later. Within- and between-day reliability of normalization tasks were similar for isoMMT3 and MVIC methods. Within- and between-day reliability of gait EMG normalized by isoMMT3 was higher than with MVIC normalization. These results indicate that EMG normalization using isoMMT3 is a reliable method with no special equipment needed and will support CGA interpretation. The next step will be to evaluate this method in pathological populations. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. US Department of Energy radiological control manual

    International Nuclear Information System (INIS)

    1994-04-01

    This manual establishes practices for the conduct of Department of Energy radiological control activities. The Manual states DOE's positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. This Manual is not a substitute for Regulations; it is intended to be consistent with all relevant statutory and regulatory requirements and shall be revised whenever necessary to ensure such consistency. Some of the Manual provisions, however, challenge the user to go well beyond minimum requirements. Following the course of action delineated in the Manual will result in achieving and surpassing related statutory or regulatory requirements

  18. Improvement of foundation for inspection

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    Japan Nuclear Energy Safety Organization has been carrying out improvement of inspection system for nuclear plants in Japan since 2003FY. The new inspection system was introduced into nuclear power plants in{sub -}2008FY. In this project, improvement of comprehensive plant performance assessment and management tool for the new inspection system are developed. In 2012FY, a trend analysis method of the plant performance was developed with reference to the IAEA literature. And the trend analysis was tried based on the results of the comprehensive plant performance assessment of all domestic plants except Fukushima-Daiichi Nuclear Power Station. In addition, the teaching materials for QMS training guideline were made. And improvement of a quality management system evaluation support tool was performed. (author)

  19. Ultrasonic inspection development at HEDL

    International Nuclear Information System (INIS)

    Day, C.K.; Mech, S.J.; Michaels, T.E.; Dixon, N.E.

    1978-01-01

    Ultrasonic testing methods and equipment are being developed to support preservice and in-service inspection of selected FFTF welds. A digital computer system is employed in the analysis of both simulated FFTF pipe sections and plate specimens containing fatigue cracks. It is anticipated that test evaluation standards containing fatigue cracks will partially eliminate questions formerly associated with weld test calibration producers by providing natural cracks which follow grain boundaries and stress patterns resembling piping situ conditions. Studies have revealed that commercial transducers may satisfy LMFBR ultrasonic pipe inspection applications: The test system evaluation included transducers and wedge coupling and fluid coupling materials which exhibited acceptable performance at temperatures to 2300C. Results are presented that demonstrate the feasibility of ultrasonic inspection of components immersed in sodium at temperatures to 2600C. (UK)

  20. Improvement of foundation for inspection

    International Nuclear Information System (INIS)

    2013-01-01

    Japan Nuclear Energy Safety Organization has been carrying out improvement of inspection system for nuclear plants in Japan since 2003FY. The new inspection system was introduced into nuclear power plants in - 2008FY. In this project, improvement of comprehensive plant performance assessment and management tool for the new inspection system are developed. In 2012FY, a trend analysis method of the plant performance was developed with reference to the IAEA literature. And the trend analysis was tried based on the results of the comprehensive plant performance assessment of all domestic plants except Fukushima-Daiichi Nuclear Power Station. In addition, the teaching materials for QMS training guideline were made. And improvement of a quality management system evaluation support tool was performed. (author)

  1. Meat safety consequences of implementing visual postmortem meat inspection procedures in Danish slaughter pigs

    DEFF Research Database (Denmark)

    Mousing, Jan; Kyrval, J.; Jensen, Tim Kåre

    1997-01-01

    The consequences of a change from a traditional meat inspection procedure, including manual handling, palpation and incision, to an entirely postmortem meat inspection procedure in Danish slaughter pigs were assessed by a comparative study of the two methods in 188,383 slaughter pigs. Out of 58...... lesion codes (selected with a prevalence less-than-or-equal-to 5.5 x 10(-5)), 26 (45 percent) were assessed either as merely aesthetic or as the healed stage of an earlier lesion and nine (15 percent) as active, but local processes, occurring only in non-edible tissue. Five lesion codes (9 percent) were...... assessed as active, non-abscessal processes occurring in edible tissue, caused by swine-specific pathogens and 10 (17 percent) were abscessal or pyaemic lesions occurring in edible tissue. Seven lesion codes (12 percent) may be associated with consumer health hazards (two frequently and five rarely...

  2. The "SAFARI" Method of Collection Study and Cooperative Acquisition for a Multi-Library Cooperative. A Manual of Procedures.

    Science.gov (United States)

    Sinclair, Dorothy

    This document examines the importance and difficulties in resource sharing and acquisition by libraries and introduces the procedures of the Site Appraisal for Area Resources Inventory (SAFARI) system as a method of comparative evaluation of subject collections among a group of libraries. Resource, or collection, sharing offers specific…

  3. Intra- and interobserver variability of MRI-based volume measurements of the hippocampus and amygdala using the manual ray-tracing method

    International Nuclear Information System (INIS)

    Achten, E.; Deblaere, K.; Damme, F. van; Kunnen, M.; Wagter, C. de; Boon, P.; Reuck, J. de

    1998-01-01

    We studied the intra- and interobserver variability of volume measurments of the hippocampus (HC) and the amygdala as applied to the detection of HC atrophy in patients with complex partial seizures (CPE), measuring the volumes of the HC and amygdala of 11 normal volunteers and 12 patients with presumed CPE, using the manual ray-tracing method. Two independent observers performed these measurements twice each using home-made software. The intra- and interobserver variability of the absolute volumes and of the normalised left-to-right volume differences (δV) between the HC (δV HC ), the amygdala (δV A ) and the sum of both (δV HCA) were assessed. In our mainly right-handed normals, the right HC and amygdala were on average 0.05 and 0.03 ml larger respectively than on the left. The interobserver variability for volume measurements in normal subjects was 1.80 ml for the HC and 0.82 ml for the amygdala, the intraobserver variability roughly one third of these values. The interobserver variability coefficient in normals was 3.6 % for δV HCA , 4.7 % for δV HC and 7.3 % for δV A . The intraobserver variability coefficient was 3.4 % for δV HCA , 4.2 % for δV HC amd 5.6 % for δV A . The variability in patients was the same for volume differences less than 5 % either side of the interval for normality, but was higher when large volume differences were encountered, is probably due to the lack of thresholding and/or normalisation. Cutoff values for lateralisation with the δV were defined. No intra- or interobserver lateralisation differences were encountered with δV HCA and δV HC . From these observations we conclude that the manual ray-tracing method is a robust method for lateralisation in patients with TLE. Due to its higher variability, this method is less suited to measure absolute volumes. (orig.) (orig.)

  4. Intra- and interobserver variability of MRI-based volume measurements of the hippocampus and amygdala using the manual ray-tracing method

    Energy Technology Data Exchange (ETDEWEB)

    Achten, E.; Deblaere, K.; Damme, F. van; Kunnen, M. [MR Department 1K12, University Hospital Gent (Belgium); Wagter, C. de [Department of Radiotherapy and Nuclear Medicine, University Hospital Gent (Belgium); Boon, P.; Reuck, J. de [Department of Neurology, University Hospital Gent (Belgium)

    1998-09-01

    We studied the intra- and interobserver variability of volume measurments of the hippocampus (HC) and the amygdala as applied to the detection of HC atrophy in patients with complex partial seizures (CPE), measuring the volumes of the HC and amygdala of 11 normal volunteers and 12 patients with presumed CPE, using the manual ray-tracing method. Two independent observers performed these measurements twice each using home-made software. The intra- and interobserver variability of the absolute volumes and of the normalised left-to-right volume differences ({delta}V) between the HC ({delta}V{sub HC}), the amygdala ({delta}V{sub A}) and the sum of both ({delta}V{sub HCA)} were assessed. In our mainly right-handed normals, the right HC and amygdala were on average 0.05 and 0.03 ml larger respectively than on the left. The interobserver variability for volume measurements in normal subjects was 1.80 ml for the HC and 0.82 ml for the amygdala, the intraobserver variability roughly one third of these values. The interobserver variability coefficient in normals was 3.6 % for {delta}V{sub HCA}, 4.7 % for {delta}V{sub HC} and 7.3 % for {delta}V{sub A}. The intraobserver variability coefficient was 3.4 % for {delta}V{sub HCA}, 4.2 % for {delta}V{sub HC} amd 5.6 % for {delta}V{sub A}. The variability in patients was the same for volume differences less than 5 % either side of the interval for normality, but was higher when large volume differences were encountered, is probably due to the lack of thresholding and/or normalisation. Cutoff values for lateralisation with the {delta}V were defined. No intra- or interobserver lateralisation differences were encountered with {delta}V{sub HCA} and {delta}V{sub HC}. From these observations we conclude that the manual ray-tracing method is a robust method for lateralisation in patients with TLE. Due to its higher variability, this method is less suited to measure absolute volumes. (orig.) (orig.) With 2 figs., 7 tabs., 23 refs.

  5. 1998 Annual Study Report. Standards development of chemical analysis and non destructive inspection methods for pure titanium metals; 1998 nendo seika hokokusho. Jun chitan no shiken hyoka hoho no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    This study was conducted to standardize the chemical analysis and non-destructive inspection methods for pure titanium metals of industrial grade. These methods are among those serving bases for international standardization of products. The chemical analysis is aimed at quantitative analysis of trace impurities, in particular, present in pure titanium metals of industrial grade by developing and standardizing the inductively coupled plasma atomic emission spectroscopy, known for its low detectable limit, and, at the same time, spark and glow discharged atomic emission spectrometry as the improved routine analysis methods. These methods, although being used by, e.g., steel makers, have not been standardized because the effects of titanium-peculiar matrix are not elucidated. The non-destructive testing is aimed at standardization of the techniques useful for automatic production lines. More concretely, these include optical methods aided by a laser or CCD camera for plate surface defect inspection, ultrasonic methods for plate internal defect inspection, and pressure differential methods for air-tightness of welded pipes. They have not been used yet for automatic production lines. (NEDO)

  6. Automated Inspection of Defects in Optical Fiber Connector End Face Using Novel Morphology Approaches.

    Science.gov (United States)

    Mei, Shuang; Wang, Yudan; Wen, Guojun; Hu, Yang

    2018-05-03

    Increasing deployment of optical fiber networks and the need for reliable high bandwidth make the task of inspecting optical fiber connector end faces a crucial process that must not be neglected. Traditional end face inspections are usually performed by manual visual methods, which are low in efficiency and poor in precision for long-term industrial applications. More seriously, the inspection results cannot be quantified for subsequent analysis. Aiming at the characteristics of typical defects in the inspection process for optical fiber end faces, we propose a novel method, “difference of min-max ranking filtering” (DO2MR), for detection of region-based defects, e.g., dirt, oil, contamination, pits, and chips, and a special model, a “linear enhancement inspector” (LEI), for the detection of scratches. The DO2MR is a morphology method that intends to determine whether a pixel belongs to a defective region by comparing the difference of gray values of pixels in the neighborhood around the pixel. The LEI is also a morphology method that is designed to search for scratches at different orientations with a special linear detector. These two approaches can be easily integrated into optical inspection equipment for automatic quality verification. As far as we know, this is the first time that complete defect detection methods for optical fiber end faces are available in the literature. Experimental results demonstrate that the proposed DO2MR and LEI models yield good comprehensive performance with high precision and accepted recall rates, and the image-level detection accuracies reach 96.0 and 89.3%, respectively.

  7. Automated Inspection of Defects in Optical Fiber Connector End Face Using Novel Morphology Approaches

    Directory of Open Access Journals (Sweden)

    Shuang Mei

    2018-05-01

    Full Text Available Increasing deployment of optical fiber networks and the need for reliable high bandwidth make the task of inspecting optical fiber connector end faces a crucial process that must not be neglected. Traditional end face inspections are usually performed by manual visual methods, which are low in efficiency and poor in precision for long-term industrial applications. More seriously, the inspection results cannot be quantified for subsequent analysis. Aiming at the characteristics of typical defects in the inspection process for optical fiber end faces, we propose a novel method, “difference of min-max ranking filtering” (DO2MR, for detection of region-based defects, e.g., dirt, oil, contamination, pits, and chips, and a special model, a “linear enhancement inspector” (LEI, for the detection of scratches. The DO2MR is a morphology method that intends to determine whether a pixel belongs to a defective region by comparing the difference of gray values of pixels in the neighborhood around the pixel. The LEI is also a morphology method that is designed to search for scratches at different orientations with a special linear detector. These two approaches can be easily integrated into optical inspection equipment for automatic quality verification. As far as we know, this is the first time that complete defect detection methods for optical fiber end faces are available in the literature. Experimental results demonstrate that the proposed DO2MR and LEI models yield good comprehensive performance with high precision and accepted recall rates, and the image-level detection accuracies reach 96.0 and 89.3%, respectively.

  8. Mechanized inspection of steam generator components during manufacture

    International Nuclear Information System (INIS)

    Otte, H.-J.; Leupoldt, K.; Meister, W.

    2009-01-01

    Steam Generator (SG) parts are intensively inspected by UT in the course of the manufacturing process. These inspections - mostly performed manually using different codes - are time consuming and call for a sophisticated documentation, figuring part of the life time documentation package. In order to reduce time and costs mechanized inspection equipment is introduced, combining short inspection times, avoiding influence of the human factor and providing proper electronic storage of all inspection results prepared for comparison with data generated during in-service inspection. Since 2001 Cegelec delivered various UT systems for gas turbine disks and rotor ends called SIRO-MAN. Within only a few years the majority of important providers of such components successfully switched from manual inspection to mechanized inspection following the requirements of manufacturers like ALSTOM, GE and Siemens. The SIRO-MAN is now adapted to the needs of mechanized inspection of SG components. The inspection is performed on the products during rotation around the vertical axis. The multi - probe assemblies are manoeuvred on the products by a manipulator system backed by a NC control unit. Acoustic coupling of UT probes to the product surface is performed with oil or water in a closed circuit. UT and - if requested ET - data along with position information of the probe assembly provided by the control unit are acquired, processed and evaluated by an UT / ET electronic system delivered by either Olympus or ZETEC. As performed already on rotor ends a sequence of inspections using different parameter settings can be programmed with simple means (Teach In) so that such inspection sequence can be executed without operating personnel. Probe assemblies allow for individual operation of probes out of the probe assembly according to the individual needs. Conventional UT and phased array applications or combination of both techniques can be provided. The UT / ET electronic equipment offers

  9. Inspecting method for fuel rods

    International Nuclear Information System (INIS)

    Watanabe, Masaaki; Kogure, Sumio.

    1976-01-01

    Purpose: To precisely detect the response of flaw in clad tube and submerged fuel pellets from a relationship between the surface of fuel rod and internal signal. Constitution: Ultrasonic reflected waves from the surface of fuel rods and the interior are detected and either one of fuel rod or ultrasonic flaw detecting contact is rotated to thereby precisely detect the response of the flaw of clad tube and submerged fuel pellets from a relationship between said surface and the interior. It will be noted that the ultrasonic flaw detecting contact used is of the line-focus type, the incident angle of ultrasonic wave from the ultrasonic flaw detecting contact relative to the fuel rod is the angle of skew, that is, the ultrasonic flaw detecting contact is not perpendicular to a center axis of the fuel rod but is slightly displace. That is, the use of the aforesaid contact may facilitate discrimination between the surface flaw of the fuel rod and the response of submergence, and in addition, the employment of the aforesaid incident angle makes it hard to receive reflected waves from the surface of the fuel rod which is great in terms of energy to facilitate discrimination of waves responsive to submergence. (Kawakami, Y.)

  10. In-service inspection of pressurized water reactors

    International Nuclear Information System (INIS)

    Rapin, M.; Saglio, R.

    1983-01-01

    French legislation, which is more demanding than in other countries, had led Electricite de France, the State-owned utility, to acquire better performance in-service inspection facilities than those which existed previously. This fact has spurred the industrial development of the new technical facilities which are used worldwide today. This article presents the ''in-service inspection machine'' (MIS) for the inspection of the welds of a PWR vessel, and the inspection device of steam generator tubes; the MIS allow a remote-viewing, ultrasonic and gamma-graphic inspection; Foucault currents are the only one method adapted to the inspection steam generator tubes [fr

  11. FY 1999 project on the development of new industry support type international standards. Standards development of chemical analysis and non-destructive inspection methods for pure titanium metals; 1999 nendo shinki sangyo shiengata kokusai hyojun kaihatsu jigyo seika hokokusho. Junchitan no shiken hyoka hoho no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    To propose it to ISOTC79 and ISOTC135, study was conducted for standardization of chemical analysis method and non-destructive inspection method for industrial use pure titanium. As the chemical analysis method, the inductively coupled plasma atomic emission spectrometry which has good detection limit was developed, and at the same time, the standardization of spark and/or glow discharged atomic emission spectrometry was developed. As the non-destructive inspection method, developmental study on the following was carried out: surface defect inspection method of pure titanium metals by laser scanning inspection system or CCD camera; internal defect inspection of pure titanium sheet and coil by plate wave ultrasonic inspection method; internal defect inspection of pure titanium bar by eddy current method; inspection of very small leakage of pressurized fluid through defects in pure titanium pipe and tube by pressure differential testing method. As a result of the study, standards of system performance and tolerance were determined in analysis of Pd, Si, Al, Cu, Mo, Zr, Nb, Ta and Y. Further, analytical conditions and application ranges of the spark discharged atomic emission spectrometry were made definite in terms of 19 elements including Mn, Fe, Ni, Cr, Sn, Pb, Si, Al, V, Cu, Mo, Zr, Nb, Ta, Co, B, Y, C and W. (NEDO)

  12. Manual lymphatic drainage with comprehensive anti-diabetic therapy (MLD / CDT as a method of treatment of lymphoedema - literature review

    Directory of Open Access Journals (Sweden)

    Ola Płoszaj

    2017-08-01

    Full Text Available Lymphedema is an accumulation of lymph, i.e stagnation of water and proteins in extracellular space and lymphatic vessel due to impairment of its transportation as an effect of congenital disorders or lymph vessel lesion. The priority in therapeutic approach to lymphedema should be establishing the cause of edema, setting medical diagnosis and treatment method as early as possible. Complex Decongestive Therapy is recommended by International Society of Lymphology and considered as a standard in lympedema treatment irrespective of their stage of development and the cause.

  13. 42 Manual

    International Nuclear Information System (INIS)

    Bergstroem, Mats.

    1990-04-01

    A program for two dimensional analysis of γ-γ coincidence matrices has been written. The program is tailored to the VT340 colour graphic terminal and written in VAX-FORTRAN. The program provides viewing of the matrix as well as projections in both energy coordinates, full two dimensional Gauss fit of maximum five peaks in one arbitrarily shaped area of the matrix, etc. A method of determining the colour scale needed has been developed. (author)

  14. Comparison of manual methods of extracting genomic DNA from dried blood spots collected on different cards: implications for clinical practice.

    Science.gov (United States)

    Molteni, C G; Terranova, L; Zampiero, A; Galeone, C; Principi, N; Esposito, S

    2013-01-01

    Isolating genomic DNA from blood samples is essential when studying the associations between genetic variants and susceptibility to a given clinical condition, or its severity. This study of three extraction techniques and two types of commercially available cards involved 219 children attending our outpatient pediatric clinic for follow-up laboratory tests after they had been hospitalised. An aliquot of venous blood was drawn into plastic tubes without additives and, after several inversions, 80 microL were put on circles of common paper cards and Whatman FTA-treated cards. Three extraction methods were compared: the Qiagen Investigator, Gensolve, and Masterpure. The best method in terms of final DNA yield was Masterpure, which led to a significantly higher yield regardless of the type of card (p less than 0.001), followed by Qiagen Investigator and Gensolve. Masterpure was also the best in terms of price, seemed to be simple and reliable, and required less hands-on time than other techniques. These conclusions support the use of Masterpure in studies that evaluate the associations between genetic variants and the severity or prevalence of infectious diseases.

  15. RADTRAN 6 Technical Manual

    Energy Technology Data Exchange (ETDEWEB)

    Weiner, Ruth F. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Neuhauser, Karen Sieglinde [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Heames, Terence John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); O' Donnell, Brandon M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Dennis, Matthew L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-01-01

    This Technical Manual contains descriptions of the calculation models and mathematical and numerical methods used in the RADTRAN 6 computer code for transportation risk and consequence assessment. The RADTRAN 6 code combines user-supplied input data with values from an internal library of physical and radiological data to calculate the expected radiological consequences and risks associated with the transportation of radioactive material. Radiological consequences and risks are estimated with numerical models of exposure pathways, receptor populations, package behavior in accidents, and accident severity and probability.

  16. RADTRAN 6 technical manual.

    Energy Technology Data Exchange (ETDEWEB)

    Weiner, Ruth F.; Neuhauser, Karen Sieglinde; Heames, Terence John; O' Donnell, Brandon M.; Dennis, Matthew L.

    2014-01-01

    This Technical Manual contains descriptions of the calculation models and mathematical and numerical methods used in the RADTRAN 6 computer code for transportation risk and consequence assessment. The RADTRAN 6 code combines user-supplied input data with values from an internal library of physical and radiological data to calculate the expected radiological consequences and risks associated with the transportation of radioactive material. Radiological consequences and risks are estimated with numerical models of exposure pathways, receptor populations, package behavior in accidents, and accident severity and probability.

  17. Short notice inspections

    International Nuclear Information System (INIS)

    Pouchkarev, V.

    1998-01-01

    For 30 years the IAEA safeguards system have evolved and have been strengthened by the regular introduction of new methods and techniques, improving both its effectiveness and efficiency. The member States of the IAEA have indicated their willingness to accept new obligations and associated technical measure that greatly strengthen the nuclear safeguards system. One element of this is the extent to which the IAEA inspectors have physical access to relevant locations for the purpose of providing independent verification of the exclusively peaceful intent of a State nuclear program. The Protocol to Safeguards granted new legal authority with respect to information on, and short notice inspector access to, all buildings on a nuclear site and administrative agreements that improve the process of designating inspectors and IAEA access to modern means of communication. This report is a short description of unannounced or short notice inspections as measures on which the new strengthened and cost efficient system will be based

  18. Effectiveness of dust control methods for crystalline silica and respirable suspended particulate matter exposure during manual concrete surface grinding.

    Science.gov (United States)

    Akbar-Khanzadeh, Farhang; Milz, Sheryl A; Wagner, Cynthia D; Bisesi, Michael S; Ames, April L; Khuder, Sadik; Susi, Pam; Akbar-Khanzadeh, Mahboubeh

    2010-12-01

    Concrete grinding exposes workers to unacceptable levels of crystalline silica dust, known to cause diseases such as silicosis and possibly lung cancer. This study examined the influence of major factors of exposure and effectiveness of existing dust control methods by simulating field concrete grinding in an enclosed workplace laboratory. Air was monitored during 201 concrete grinding sessions while using a variety of grinders, accessories, and existing dust control methods, including general ventilation (GV), local exhaust ventilation (LEV), and wet grinding. Task-specific geometric mean (GM) of respirable crystalline silica dust concentrations (mg/m³ for LEV:HEPA-, LEV:Shop-vac-, wet-, and uncontrolled-grinding, while GV was off/on, were 0.17/0.09, 0.57/0.13, 1.11/0.44, and 23.1/6.80, respectively. Silica dust concentrations (mg/m³ using 100-125 mm (4-5 inch) and 180 mm (7 inch) grinding cups were 0.53/0.22 and 2.43/0.56, respectively. GM concentrations of silica dust were significantly lower for (1) GV on (66.0%) vs. off, and (2) LEV:HEPA- (99.0%), LEV:Shop-vac- (98.1%) or wet- (94.4%) vs. uncontrolled-grinding. Task-specific GM of respirable suspended particulate matter (RSP) concentrations (mg/m³ for LEV:HEPA-, LEV:Shop-vac-, wet-, and uncontrolled grinding, while GV was off/on, were 1.58/0.63, 7.20/1.15, 9.52/4.13, and 152/47.8, respectively. GM concentrations of RSP using 100-125 mm and 180 mm grinding cups were 4.78/1.62 and 22.2/5.06, respectively. GM concentrations of RSP were significantly lower for (1) GV on (70.2%) vs. off, and (2) LEV:HEPA- (98.9%), LEV:Shop-vac- (96.9%) or wet- (92.6%) vs. uncontrolled grinding. Silica dust and RSP were not significantly affected by (1) orientation of grinding surfaces (vertical vs. inclined); (2) water flow rates for wet grinding; (3) length of task-specific sampling time; or, (4) among cup sizes of 100, 115 or 125 mm. No combination of factors or control methods reduced an 8-hr exposure level to below the

  19. FAA Fluorescent Penetrant Laboratory Inspections

    Energy Technology Data Exchange (ETDEWEB)

    WINDES,CONNOR L.; MOORE,DAVID G.

    2000-08-02

    The Federal Aviation Administration Airworthiness Assurance NDI Validation Center currently assesses the capability of various non-destructive inspection (NDI) methods used for analyzing aircraft components. The focus of one such exercise is to evaluate the sensitivity of fluorescent liquid penetrant inspection. A baseline procedure using the water-washable fluorescent penetrant method defines a foundation for comparing the brightness of low cycle fatigue cracks in titanium test panels. The analysis of deviations in the baseline procedure will determine an acceptable range of operation for the steps in the inspection process. The data also gives insight into the depth of each crack and which step(s) of the inspection process most affect penetrant sensitivities. A set of six low cycle fatigue cracks produced in 6.35-mm thick Ti-6Al-4V specimens was used to conduct the experiments to produce sensitivity data. The results will document the consistency of the crack readings and compare previous experiments to find the best parameters for water-washable penetrant.

  20. Optical fiber inspection system

    Science.gov (United States)

    Moore, Francis W.

    1987-01-01

    A remote optical inspection system including an inspection head. The inspection head has a passageway through which pellets or other objects are passed. A window is provided along the passageway through which light is beamed against the objects being inspected. A plurality of lens assemblies are arranged about the window so that reflected light can be gathered and transferred to a plurality of coherent optical fiber light guides. The light guides transfer the light images to a television or other image transducer which converts the optical images into a representative electronic signal. The electronic signal can then be displayed on a signal viewer such as a television monitor for inspection by a person. A staging means can be used to support the objects for viewing through the window. Routing means can be used to direct inspected objects into appropriate exit passages for accepted or rejected objects. The inspected objects are advantageously fed in a singular manner to the staging means and routing means. The inspection system is advantageously used in an enclosure when toxic or hazardous materials are being inspected.

  1. 46 CFR 153.812 - Inspection for Certificate of Inspection.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Inspection for Certificate of Inspection. 153.812... CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Testing and Inspection § 153.812 Inspection for Certificate of Inspection. The rules governing the...

  2. ROOFER Inventory Procedures and Inspection Manual for Metal Panel Roofing

    Science.gov (United States)

    2012-12-01

    System. DISCLAIMER: The contents of this report are not to be used for advertising , publication, or promotional purposes. Citation of trade names does...and ollow<~g wacor to penwate CPM ~~~s~ dented. delormed or kinked. tlllow<~g pondong w’"er and/or Domogt<!Pen., C>-’H ~:,~.: ~~:r~~·~:,:;••system

  3. Manual on decontamination of surfaces

    International Nuclear Information System (INIS)

    1979-01-01

    The manual is intended for those who are responsible for the organization and implementation of decontamination programmes for facilities where radioactive materials are handled mainly on a laboratory scale. It contains information and guidelines on practical methods for decontaminating working spaces, equipment, laboratory benches and protective clothing. Useful information is also provided on the removal of loose skin contamination from personnel by mild, non-medical processes. Methods of removing skin contamination needing medical supervision, or of internal decontamination, which is entirely a medical process, are not covered in this manual. Large-scale decontamination of big nuclear facilities is also considered as outside its scope

  4. Comparison of Deep Packet Inspection (DPI) Tools for Traffic Classification

    DEFF Research Database (Denmark)

    Bujlow, Tomasz; Carela-Español, Valentín; Barlet-Ros, Pere

    the researchers do not only have the full payloads, but also they are provided the information which application created the flow. Therefore, the dataset is useful for testing Deep Packet Inspection (DPI) tools, as well as statistical, and port-based classifiers. The dataset was created in a fully manual way...

  5. The Management Advisory Committee of the Inspection Validation Centre. 2nd report

    International Nuclear Information System (INIS)

    1985-06-01

    The document is the second report of the Management Advisory Committee of the Inspection Validation Centre (I.V.C.). The IVC is concerned with the ultrasonic inspection of the CEGB's proposed PWR reactor pressure vessel, and other components. The report deals with the technical progress since May 1984, and includes: interim validation, retrospective validation, examination of procedures, test assembly manufacture, interim validation of manual forging inspections, and validation facilities. (U.K.)

  6. Development of an amphibious robot for visual inspection of APR1400 Npp IRWST strainer

    International Nuclear Information System (INIS)

    Jang, You Hyun; Kim, Jong Seog

    2014-01-01

    An amphibious inspection robot system (hereafter AIROS) is being developed to visually inspect the in-containment refueling storage water tank (hereafter IRWST) strainer in APR1400 instead of a human diver. Four IRWST strainers are located in the IRWST, which is filled with boric acid water. Each strainer has 108 sub-assembly strainer fin modules that should be inspected with the VT-3 method according to Reg. guide 1.82 and the operation manual. AIROS has 6 thrusters for submarine voyage and 4 legs for walking on the top of the strainer. An inverse kinematic algorithm was implemented in the robot controller for exact walking on the top of the IRWST strainer. The IRWST strainer has several top cross braces that are extruded on the top of the strainer, which can be obstacles of walking on the strainer, to maintain the frame of the strainer. Therefore, a robot leg should arrive at the position beside the top cross brace. For this reason, we used an image processing technique to find the top cross brace in the sole camera image. The sole camera image is processed to find the existence of the top cross brace using the cross edge detection algorithm in real time. A 5-DOF robot arm that has multiple camera modules for simultaneous inspection of both sides can penetrate narrow gaps. For intuitive presentation of inspection results and for management of inspection data, inspection images are stored in the control PC with camera angles and positions to synthesize and merge the images. The synthesized images are then mapped in a 3D CAD model of the IRWST strainer with the location information. An IRWST strainer mock-up was fabricated to teach the robot arm scanning and gaiting. It is important to arrive at the designated position for inserting the robot arm into all of the gaps. Exact position control without anchor under the water is not easy. Therefore, we designed the multi leg robot for the role of anchoring and positioning. Quadruped robot design of installing sole

  7. Development of an amphibious robot for visual inspection of APR1400 Npp IRWST strainer

    Energy Technology Data Exchange (ETDEWEB)

    Jang, You Hyun; Kim, Jong Seog [Korea Hydro Nuclear Power Central Research Institute, Daejeon (Korea, Republic of)

    2014-06-15

    An amphibious inspection robot system (hereafter AIROS) is being developed to visually inspect the in-containment refueling storage water tank (hereafter IRWST) strainer in APR1400 instead of a human diver. Four IRWST strainers are located in the IRWST, which is filled with boric acid water. Each strainer has 108 sub-assembly strainer fin modules that should be inspected with the VT-3 method according to Reg. guide 1.82 and the operation manual. AIROS has 6 thrusters for submarine voyage and 4 legs for walking on the top of the strainer. An inverse kinematic algorithm was implemented in the robot controller for exact walking on the top of the IRWST strainer. The IRWST strainer has several top cross braces that are extruded on the top of the strainer, which can be obstacles of walking on the strainer, to maintain the frame of the strainer. Therefore, a robot leg should arrive at the position beside the top cross brace. For this reason, we used an image processing technique to find the top cross brace in the sole camera image. The sole camera image is processed to find the existence of the top cross brace using the cross edge detection algorithm in real time. A 5-DOF robot arm that has multiple camera modules for simultaneous inspection of both sides can penetrate narrow gaps. For intuitive presentation of inspection results and for management of inspection data, inspection images are stored in the control PC with camera angles and positions to synthesize and merge the images. The synthesized images are then mapped in a 3D CAD model of the IRWST strainer with the location information. An IRWST strainer mock-up was fabricated to teach the robot arm scanning and gaiting. It is important to arrive at the designated position for inserting the robot arm into all of the gaps. Exact position control without anchor under the water is not easy. Therefore, we designed the multi leg robot for the role of anchoring and positioning. Quadruped robot design of installing sole

  8. DEVELOPMENT OF AN AMPHIBIOUS ROBOT FOR VISUAL INSPECTION OF APR1400 NPP IRWST STRAINER ASSEMBLY

    Directory of Open Access Journals (Sweden)

    YOU HYUN JANG

    2014-06-01

    Full Text Available An amphibious inspection robot system (hereafter AIROS is being developed to visually inspect the in-containment refueling storage water tank (hereafter IRWST strainer in APR1400 instead of a human diver. Four IRWST strainers are located in the IRWST, which is filled with boric acid water. Each strainer has 108 sub-assembly strainer fin modules that should be inspected with the VT-3 method according to Reg. guide 1.82 and the operation manual. AIROS has 6 thrusters for submarine voyage and 4 legs for walking on the top of the strainer. An inverse kinematic algorithm was implemented in the robot controller for exact walking on the top of the IRWST strainer. The IRWST strainer has several top cross braces that are extruded on the top of the strainer, which can be obstacles of walking on the strainer, to maintain the frame of the strainer. Therefore, a robot leg should arrive at the position beside the top cross brace. For this reason, we used an image processing technique to find the top cross brace in the sole camera image. The sole camera image is processed to find the existence of the top cross brace using the cross edge detection algorithm in real time. A 5-DOF robot arm that has multiple camera modules for simultaneous inspection of both sides can penetrate narrow gaps. For intuitive presentation of inspection results and for management of inspection data, inspection images are stored in the control PC with camera angles and positions to synthesize and merge the images. The synthesized images are then mapped in a 3D CAD model of the IRWST strainer with the location information. An IRWST strainer mock-up was fabricated to teach the robot arm scanning and gaiting. It is important to arrive at the designated position for inserting the robot arm into all of the gaps. Exact position control without anchor under the water is not easy. Therefore, we designed the multi leg robot for the role of anchoring and positioning. Quadruped robot design of

  9. SYVAC3 manual

    International Nuclear Information System (INIS)

    Andres, T.H.

    2000-01-01

    SYVAC3 (Systems Variability Analysis Code, generation 3) is a computer program that implements a method called systems variability analysis to analyze the behaviour of a system in the presence of uncertainty. This method is based on simulating the system many times to determine the variation in behaviour it can exhibit. SYVAC3 specializes in systems representing the transport of contaminants, and has several features to simplify the modelling of such systems. It provides a general tool for estimating environmental impacts from the dispersal of contaminants. This report describes the use and structure of SYVAC3. It is intended for modellers, programmers, operators and reviewers who deal with simulation codes based on SYVAC3. From this manual they can learn how to link a model with SYVAC3, how to set up an input file, and how to extract results from output files. The manual lists the subroutines of SYVAC3 that are available for use by models, and describes their argument lists. It also gives an overview of how routines in the File Reading Package, the Parameter Sampling Package and the Time Series Package can be used by programs outside of SYVAC3. (author)

  10. SYVAC3 manual

    Energy Technology Data Exchange (ETDEWEB)

    Andres, T.H

    2000-07-01

    SYVAC3 (Systems Variability Analysis Code, generation 3) is a computer program that implements a method called systems variability analysis to analyze the behaviour of a system in the presence of uncertainty. This method is based on simulating the system many times to determine the variation in behaviour it can exhibit. SYVAC3 specializes in systems representing the transport of contaminants, and has several features to simplify the modelling of such systems. It provides a general tool for estimating environmental impacts from the dispersal of contaminants. This report describes the use and structure of SYVAC3. It is intended for modellers, programmers, operators and reviewers who deal with simulation codes based on SYVAC3. From this manual they can learn how to link a model with SYVAC3, how to set up an input file, and how to extract results from output files. The manual lists the subroutines of SYVAC3 that are available for use by models, and describes their argument lists. It also gives an overview of how routines in the File Reading Package, the Parameter Sampling Package and the Time Series Package can be used by programs outside of SYVAC3. (author)

  11. Typical NRC inspection procedures for model plant

    International Nuclear Information System (INIS)

    Blaylock, J.

    1984-01-01

    A summary of NRC inspection procedures for a model LEU fuel fabrication plant is presented. Procedures and methods for combining inventory data, seals, measurement techniques, and statistical analysis are emphasized

  12. Inservice inspection of Halden BWR pressure vessel

    International Nuclear Information System (INIS)

    Foerli, O.; Hernes, T.

    1978-01-01

    A description is given of how the recertification inspection of the 20 years old Halden Reactor pressure vessel was carried out in accordance with the latest ASME-CODES, despite the fact that inspection accessibility was poor. As no volumetric inspection had been carried out since the preservice radiography in 1957, the ultrasonic inspection included the high flux region of all welds. In total 70% of longitudinal welds and 20% of bottom circumferential welds were inspected as well as the bottom nozzle connection. The vessel was not designed with provisions for inservice inspection, the welds are unaccessible from the outside and removal of the lid is virtually impossible. The ultrasonic probes could only be loaded through 77 mm diameter holes in the top lid and remotely positioned inside the vessel. The inspection was performed using 450C and 60OC 1 MHz angle probes and 2.25 MHz normal probes in immersion technique. In a zone around the welds, small regions with lack of bonding between the stainless steel cladding and the boiler steel were revealed. One root defect known and accepted from the preservice radiographs was examined. The defect was found to be 6x30mm as a maximum and well within acceptable limits according to the fracture mechanics analysis method recommended in ASME X1. The inspection required a period of three weeks' work in the reactor hall. (UK)

  13. An introduction to and description of the first Spanish applications of slôjd (a system of manual work following the Swedish Nads method

    Directory of Open Access Journals (Sweden)

    Francesca COMAS RUBÍ

    2013-11-01

    Full Text Available The study and application of the Nads slôjd system of manual work with wood is known to have become a compulsory part of the syllabus in Spanish state schools in 1901, thanks to a Royal Decree signed by the then Minister of Education, the Honourable Romanones. However, written history is far less familiar with questions such as how this system came to be known in Spain, when it was introduced, who encouraged its use or where and how it was first applied. In this study, with the aid of a large number of hitherto unpublished documents (some of which were found in Nààs, Sweden, we shall try to answer these questions and, as a result, produce a detailed analysis of the introduction of Nads slojd to Spain at the end of the 19th century, strangely enough (or perhaps not under the clear, but implicit influence of the Spanish movement for free-thinking methods of education.

  14. Technical regulation of nondestructive inspection

    International Nuclear Information System (INIS)

    1995-01-01

    It starts with the explanation of definition of nondestructive inspection and qualifications for a inspection. It lists the technical regulations of nondestructive inspections which are radiographic testing, ultrasonic flaw detecting test, liquid penetrant test, magnetic particle inspection, eddy current test visual inspection and leakage test.

  15. A Manual of Style.

    Science.gov (United States)

    Nebraska State Dept. of Education, Lincoln.

    This "Manual of Style" is offered as a guide to assist Nebraska State employees in producing quality written communications and in presenting a consistently professional image of government documents. The manual is not designed to be all-inclusive. Sections of the manual discuss formatting documents, memorandums, letters, mailing…

  16. MAP user's manual copyright

    International Nuclear Information System (INIS)

    Pillsbury, R.D. Jr.

    1991-12-01

    The program MITMAP represents a set of general purpose, two- dimensional, finite element programs for the calculation of magnetic fields. It consists of the program MAP and MAP2DJ. The two programs are used to solve different electromagnetic problems, but they have a common set of subrountines for pre- and postprocessing. Originally separate programs, they have been combined to make modification easier. The manuals, however, will remain separate. The program MAP is described in this manual. MAP is applicable to the class of problems with two-dimensional-planar or axisymmetric - geometries, in which the current density and the magnetic vector potential have only a single nonvanishing component. The single component is associated with the direction that is perpendicular to the plane of the problem and is invariant with respect to that direction. Maxwell's equations can be reduced to a solver diffusion equation in terms of the single, nonvanishing component of the magnetic vector potential for planar problems and to a single component of a vector potential for planar problems and to a single component of a vector diffusion equation for axisymmetric problems. The magnetic permeability appears in the governing equation. The permeability may be a function of the magnetic flux density. In addition, any electrically conducting material present will have eddy currents induced by a time varying magnetic field. These eddy currents must be included in the solution process. This manual provides a description of the structure of the input data and output for the program. There are several example problems presented that illustrate the major program features. Appendices are included that contain a derivation of the governing equations and the application of the finite element method to the solution of the equations

  17. Link Between RI-ISI and Inspection Qualification: Relationship between Defect Detection Rate and Margin of Detection

    International Nuclear Information System (INIS)

    Shepherd, Barrie; Goujon, Sophie; Whittle, John

    2007-01-01

    Quantitative risk-informed in-service inspection (RI-ISI) requires a quantitative measurement of inspection effectiveness if the risk change associated with an inspection is to be determined. Knowing the probability of detection (POD) as a function of defect depth (through wall dimension) would provide ideal information. However the main in-service inspection method for nuclear plant is ultrasonics, for which defect detection capability depends on a wide variety of parameters besides defect depth, such as defect orientation, roughness, location, shape etc. In recognition of this the European approach to inspection qualification is generally based on some combination of technical justification, and practical trials on a relatively limited number of defects. This inspection qualification process involves demonstrating that defects of concern will generate responses in excess of the specified recording level or noise, depending on the inspection. It is not currently designed to quantify the probability with which defects will be detected. The work described in this report has been performed in order to help address the problem of how the information generated during inspection qualification can be used as an input for RI-ISI. The approach adopted has been to recognise that as the defect response increases above the recording or noise level, the probability of detecting defects is likely to increase. The work therefore involved an investigation of the relationship between POD (strictly speaking defect detection rate) and margin of detection. It involved blind manual and automated ultrasonic trials on artificial defects in test plates designed to generate a range of signal responses. The detection rate for defects which provided signals at a particular level above noise or above a recording level was then measured. A relationship between defect detection rate and margin of detection has been established based on these trials. In addition to establishing a stronger link

  18. Health products inspection

    International Nuclear Information System (INIS)

    Stoltz, M.

    2009-01-01

    To protect public health, the Health Products Inspection is a public service mission where the application of regulations concerning activities on human health products and cosmetic products is verified. This mission permits a global approach to assess the health products risk-based benefit and, in monitoring by laboratory testing and by on site inspections, to verify their compliance with appropriate regulations. The seventy five inspectors perform about eight hundred inspections per year, in France and abroad. These inspections are related to data provided in the health products assessment and also to manufacturing and delivery practices. The French inspection body is also involved in the training of foreign inspectors and in the harmonization of national, European and international practices either for operators than for the competent authorities. (author)

  19. Thermographic inspection of pipes, tanks, and containment liners

    Energy Technology Data Exchange (ETDEWEB)

    Renshaw, Jeremy B., E-mail: jrenshaw@epri.com; Muthu, Nathan [Electric Power Research Institute, 1300 West WT Harris Blvd., Charlotte, NC 28262 (United States); Lhota, James R.; Shepard, Steven M., E-mail: sshepard@thermalwave.com [Thermal Wave Imaging, 845 Livernois St., Ferndale, MI 48220 (United States)

    2015-03-31

    Nuclear power plants are required to operate at a high level of safety. Recent industry and license renewal commitments aim to further increase safety by requiring the inspection of components that have not traditionally undergone detailed inspected in the past, such as tanks and liners. NEI 09-14 requires the inspection of buried pipes and tanks while containment liner inspections are required as a part of license renewal commitments. Containment liner inspections must inspect the carbon steel liner for defects - such as corrosion - that could threaten the pressure boundary and ideally, should be able to inspect the surrounding concrete for foreign material that could be in contact with the steel liner and potentially initiate corrosion. Such an inspection requires a simultaneous evaluation of two materials with very different material properties. Rapid, yet detailed, inspection results are required due to the massive size of the tanks and containment liners to be inspected. For this reason, thermal NDE methods were evaluated to inspect tank and containment liner mockups with simulated defects. Thermographic Signal Reconstruction (TSR) was utilized to enhance the images and provide detailed information on the sizes and shapes of the observed defects. The results show that thermographic inspection is highly sensitive to the defects of interest and is capable of rapidly inspecting large areas.

  20. Manual for soil physical measurements; Version 3

    NARCIS (Netherlands)

    Stolte, J.

    1997-01-01

    Manuals are given for several laboratory methods for determining hydraulic conductivity, water retention and shrinkage characteristics of soil. Measurement techniques described are: the constant-head and falling-head methods for saturated conductivitythe drip infiltrometer for unsaturated

  1. Automated Quantification of Optic Nerve Axons in Primate Glaucomatous and Normal Eyes—Method and Comparison to Semi-Automated Manual Quantification

    Science.gov (United States)

    Reynaud, Juan; Cull, Grant; Wang, Lin; Fortune, Brad; Gardiner, Stuart; Burgoyne, Claude F; Cioffi, George A

    2012-01-01

    Purpose. To describe an algorithm and software application (APP) for 100% optic nerve axon counting and to compare its performance with a semi-automated manual (SAM) method in optic nerve cross-section images (images) from normal and experimental glaucoma (EG) nonhuman primate (NHP) eyes. Methods. ON cross sections from eight EG eyes from eight NHPs, five EG and five normal eyes from five NHPs, and 12 normal eyes from 12 NHPs were imaged at 100×. Calibration (n = 500) and validation (n = 50) image sets ranging from normal to end-stage damage were assembled. Correlation between APP and SAM axon counts was assessed by Deming regression within the calibration set and a compensation formula was generated to account for the subtle, systematic differences. Then, compensated APP counts for each validation image were compared with the mean and 95% confidence interval of five SAM counts of the validation set performed by a single observer. Results. Calibration set APP counts linearly correlated to SAM counts (APP = 10.77 + 1.03 [SAM]; R2 = 0.94, P < 0.0001) in normal to end-stage damage images. In the validation set, compensated APP counts fell within the 95% confidence interval of the SAM counts in 42 of the 50 images and were within 12 axons of the confidence intervals in six of the eight remaining images. Uncompensated axon density maps for the normal and EG eyes of a representative NHP were generated. Conclusions. An APP for 100% ON axon counts has been calibrated and validated relative to SAM counts in normal and EG NHP eyes. PMID:22467571

  2. LCS Users Manual

    International Nuclear Information System (INIS)

    Redd, A.J.; Ignat, D.W.

    1998-01-01

    The Lower Hybrid Simulation Code (LSC) is a computational model of lower hybrid current drive in the presence of an electric field. Details of geometry, plasma profiles, and circuit equations are treated. Two-dimensional velocity space effects are approximated in a one-dimensional Fokker-Planck treatment. The LSC was originally written to be a module for lower hybrid current drive called by the Tokamak Simulation Code (TSC), which is a numerical model of an axisymmetric tokamak plasma and the associated control systems. The TSC simulates the time evolution of a free boundary plasma by solving the MHD equations on a rectangular computational grid. The MHD equations are coupled to the external circuits (representing poloidal field coils) through the boundary conditions. The code includes provisions for modeling the control system, external heating, and fusion heating. The LSC module can also be called by the TRANSP code. TRANSP represents the plasma with an axisymmetric, fixed-boundary model and focuses on calculation of plasma transport to determine transport coefficients from data on power inputs and parameters reached. This manual covers the basic material needed to use the LSC. If run in conjunction with TSC, the ''TSC Users Manual'' should be consulted. If run in conjunction with TRANSP, on-line documentation will be helpful. A theoretical background of the governing equations and numerical methods is given. Information on obtaining, compiling, and running the code is also provided

  3. ARDS User Manual

    Science.gov (United States)

    Fleming, David P.

    2001-01-01

    Personal computers (PCs) are now used extensively for engineering analysis. their capability exceeds that of mainframe computers of only a few years ago. Programs originally written for mainframes have been ported to PCs to make their use easier. One of these programs is ARDS (Analysis of Rotor Dynamic Systems) which was developed at Arizona State University (ASU) by Nelson et al. to quickly and accurately analyze rotor steady state and transient response using the method of component mode synthesis. The original ARDS program was ported to the PC in 1995. Several extensions were made at ASU to increase the capability of mainframe ARDS. These extensions have also been incorporated into the PC version of ARDS. Each mainframe extension had its own user manual generally covering only that extension. Thus to exploit the full capability of ARDS required a large set of user manuals. Moreover, necessary changes and enhancements for PC ARDS were undocumented. The present document is intended to remedy those problems by combining all pertinent information needed for the use of PC ARDS into one volume.

  4. Heat exchanger tube inspection using ultrasonic arrays

    International Nuclear Information System (INIS)

    Meyer, P.A.; Carodiskey, T.J.

    1986-01-01

    Tubing used in industrial heat exchangers is often subject to failure caused by corrosion and cracking. Technical conferences are used as a forum in the steam generator industry to ensure that the failure mechanisms are well understood and that the quality of the heat exchanger is maintained. The quality of a heat exchanger can be thought of as its ability to operate to design specifications over its intended life. This is the motivation to inspect and evaluate these devices periodically. Inspection, however, normally requires shutdown of the heat exchanger which is costly but is much more acceptable than an unscheduled shutdown due to failure of a tube. Therefore, the degree of inspection is established by balancing the cost of inspection with the risk of a tube failure. Any method of reducing the cost of inspection will permit a higher degree of inspection and, therefore, improve heat exchanger quality. This paper reviews the design and performance of an improved method of ultrasonic inspection of heat exchanger tubing with emphasis on applications in the nuclear industry

  5. 49 CFR 236.919 - Operations and Maintenance Manual.

    Science.gov (United States)

    2010-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Standards for Processor-Based Signal and Train Control Systems § 236.919 Operations and Maintenance Manual. (a... identify all software versions, revisions, and revision dates. Plans must be legible and correct. (c...

  6. 49 CFR 236.1039 - Operations and Maintenance Manual.

    Science.gov (United States)

    2010-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Positive Train Control Systems § 236.1039 Operations and Maintenance Manual. (a) The railroad shall catalog and... software versions, revisions, and revision dates. Plans must be legible and correct. (c) Hardware, software...

  7. Eddy current inspection of stationary blade rings

    International Nuclear Information System (INIS)

    Krzywosz, K.J.; Hastings, S.N.

    1994-01-01

    Stationary turbine blade rings in a US power plant have experienced chloride-induced cracking. Failure analysis determined two types of cracking mechanisms: corrosion fatigue cracking confined to the leading edge of the outer shroud; and stress corrosion cracking present all over the blade surface. Fluorescent dye penetrant is typically used to detect and size cracks. However, it requires cleaning the blade rings by sandblasting to obtain reliable inspection results. Sand blasting in turn requires sealing the lower half of the turbine housing to prevent sand from contaminating the rest of the power plant components. Furthermore, both the penetrant examination and the removal of the sand are time consuming and costly. An alternative NDE technique is desirable which requires no pre-cleaning of the blade and a quick go/no-go inspection with the capability of estimating the crack length. This paper presents an innovative eddy current technique which meets the desired objectives by incorporating the use of specially designed contoured scanners equipped with an array of pancake coils. A set of eddy current pancake coils housed in three different scanners is used to manually scan and inspect the convex side of the stationary blade rings. The pancake coils are operated in a transmit/receive mode using two separate eddy current instruments. This paper presents the inspection concept, including scanner and probe designs, and test results from the various stages of multiple blade rings

  8. Electronic Out-fall Inspection Application - 12007

    Energy Technology Data Exchange (ETDEWEB)

    Weymouth, A Kent III; Pham, Minh; Messick, Chuck [Savannah River Nuclear Solutions, Aiken, South Carolina 29808 (United States)

    2012-07-01

    In early 2009 an exciting opportunity was presented to the Geographic Information Systems (GIS) team at the Savannah River Site (SRS). The SRS maintenance group was directed to maintain all Out-falls on Site, increasing their workload from 75 to 183 out-falls with no additional resources. The existing out-fall inspection system consisted of inspections performed manually and documented via paper trail. The inspections were closed out upon completion of activities and placed in file cabinets with no central location for tracking/trending maintenance activities. A platform for meeting new improvements required for documentation by the Department of Health and Environmental Control (DHEC) out-fall permits was needed to replace this current system that had been in place since the 1980's. This was accomplished by building a geographically aware electronic application that improved reliability of site out-fall maintenance and ensured consistent standards were maintained for environmental excellence and worker efficiency. Inspections are now performed via tablet and uploaded to a central point. Work orders are completed and closed either in the field using tablets (mobile application) or in their offices (via web portal) using PCs. And finally completed work orders are now stored in a central database allowing trending of maintenance activities. (authors)

  9. Reliability of application of inspection procedures

    Energy Technology Data Exchange (ETDEWEB)

    Murgatroyd, R A

    1988-12-31

    This document deals with the reliability of application of inspection procedures. A method to ensure that the inspection of defects thanks to fracture mechanics is reliable is described. The Systematic Human Error Reduction and Prediction Analysis (SHERPA) methodology is applied to every task performed by the inspector to estimate the possibility of error. It appears that it is essential that inspection procedures should be sufficiently rigorous to avoid substantial errors, and that the selection procedures and the training period for inspectors should be optimised. (TEC). 3 refs.

  10. Risk-based methodology for USNRC inspections

    International Nuclear Information System (INIS)

    Wong, S.M.; Holahan, G.M.; Chung, J.W.; Johnson, M.R.

    1995-01-01

    This paper describes the development and trial applications of a risk-based methodology to enhance the inspection processes for US nuclear power plants. Objectives of risk-based methods to complement prescriptive engineering approaches in US Nuclear Regulatory Commission (USNRC) inspection programs are presented. Insights from time-dependent risk profiles of plant configurational from Individual Plant Evaluation (IPE) studies were integrated to develop a framework for optimizing inspection efforts in NRC regulatory initiatives. Lessons learned from NRC pilot applications of the risk-based methodology for evaluation of the effectiveness of operational risk management programs at US nuclear power plant sites are also discussed

  11. Reliability of application of inspection procedures

    International Nuclear Information System (INIS)

    Murgatroyd, R.A.

    1988-01-01

    This document deals with the reliability of application of inspection procedures. A method to ensure that the inspection of defects thanks to fracture mechanics is reliable is described. The Systematic Human Error Reduction and Prediction Analysis (SHERPA) methodology is applied to every task performed by the inspector to estimate the possibility of error. It appears that it is essential that inspection procedures should be sufficiently rigorous to avoid substantial errors, and that the selection procedures and the training period for inspectors should be optimised. (TEC)

  12. Inspections in veterinary medicine 2005; Veterinaerinspektioner 2005

    Energy Technology Data Exchange (ETDEWEB)

    Joensson, Helene

    2006-11-15

    In Sweden 300 veterinary clinics have a license for x-ray diagnostics. Six of them also have a license for nuclear medicine. During 2005 eight clinics were inspected and the results show that the radiation protection in veterinary medicine can be improved. No clinic fulfilled the regulations of categorization of workplaces and workers (SSI FS 1998:3). Half of the clinics had no Swedish manual to the x-ray equipment and just as many had not performed the annual function check. Obviously, there is a need for more information to staff in veterinary medicine.

  13. Runway Inspection by RPAS

    Directory of Open Access Journals (Sweden)

    Stanislav Absolon

    2015-10-01

    Full Text Available This article discusses the use of the RPAS for the inspection of the airport operating areas. The paper compares the current process of the inspection of the airport operating areas by the airport staff with the possibilities which are offered by the use of the modern technology RPAS. The following text also describes how to inspect airport operating areas by the RPAS, specific technical possibilities and the applicable technical solutions. Furthermore there are variants of piloting the RPAS, comparing usable equipment, equipment for video recording and the possibility of using thermal imaging camera in the article.

  14. Magnetic rubber inspection (MRI)

    International Nuclear Information System (INIS)

    Carro, L.

    1997-01-01

    Magnetic Rubber Inspection (MRI) was developed to inspect for small cracks and flaws encountered in high performance aircraft. A formula of very fine magnetic particles immersed in a room temperature curing rubber is catalysed and poured into dams (retainers) on the surface of the part to be inspected. Inducing a magnetic field then causes the particles to be drawn to discontinuities in the component under test. These indicating particles are held to the discontinuity by magnetic attraction, as the rubber cures. The solid rubber cast (Replica) is then removed and examined under a microscope for indicating lines of particle concentrations. 3 refs., 6 figs

  15. Manually operated small envelope scanner system

    Energy Technology Data Exchange (ETDEWEB)

    Sword, Charles Keith

    2017-04-18

    A scanner system and method for acquisition of position-based ultrasonic inspection data are described. The scanner system includes an inspection probe and a first non-contact linear encoder having a first sensor and a first scale to track inspection probe position. The first sensor is positioned to maintain a continuous non-contact interface between the first sensor and the first scale and to maintain a continuous alignment of the first sensor with the inspection probe. The scanner system may be used to acquire two-dimensional inspection probe position data by including a second non-contact linear encoder having a second sensor and a second scale, the second sensor positioned to maintain a continuous non-contact interface between the second sensor and the second scale and to maintain a continuous alignment of the second sensor with the first sensor.

  16. Automated quantification of optic nerve axons in primate glaucomatous and normal eyes--method and comparison to semi-automated manual quantification.

    Science.gov (United States)

    Reynaud, Juan; Cull, Grant; Wang, Lin; Fortune, Brad; Gardiner, Stuart; Burgoyne, Claude F; Cioffi, George A

    2012-05-01

    To describe an algorithm and software application (APP) for 100% optic nerve axon counting and to compare its performance with a semi-automated manual (SAM) method in optic nerve cross-section images (images) from normal and experimental glaucoma (EG) nonhuman primate (NHP) eyes. ON cross sections from eight EG eyes from eight NHPs, five EG and five normal eyes from five NHPs, and 12 normal eyes from 12 NHPs were imaged at 100×. Calibration (n = 500) and validation (n = 50) image sets ranging from normal to end-stage damage were assembled. Correlation between APP and SAM axon counts was assessed by Deming regression within the calibration set and a compensation formula was generated to account for the subtle, systematic differences. Then, compensated APP counts for each validation image were compared with the mean and 95% confidence interval of five SAM counts of the validation set performed by a single observer. Calibration set APP counts linearly correlated to SAM counts (APP = 10.77 + 1.03 [SAM]; R(2) = 0.94, P < 0.0001) in normal to end-stage damage images. In the validation set, compensated APP counts fell within the 95% confidence interval of the SAM counts in 42 of the 50 images and were within 12 axons of the confidence intervals in six of the eight remaining images. Uncompensated axon density maps for the normal and EG eyes of a representative NHP were generated. An APP for 100% ON axon counts has been calibrated and validated relative to SAM counts in normal and EG NHP eyes.

  17. Manual on training, qualification and certification of quality assurance personnel

    International Nuclear Information System (INIS)

    1986-01-01

    The Manual is applicable to those participants in a nuclear power project who are associated with establishment and implementation of the various quality assurance (QA) programmes during the life cycle of the project. It provides examples of typical QA functions to be undertaken and the associated qualification requirements, training programmes, training techniques and methods of certification of personnel implementing these functions. The necessary qualification and training requirements and practices for QA personnel are dependent primarily on the functions or activities to be performed. The two main functions of the QA unit noted previously as (a) ensuring QA programme establishment and execution and (b) verifying that activities have been correctly performed have been found in practice to require different qualifications and training of personnel. Therefore, for the purpose of this Manual the QA personnel may be classified in two groups who perform: QA programmatic and evaluation functions; Inspection and test functions. These titles do not necessarily represent separate or individual organizational groups or units and may be composed of one or of several different organizations

  18. Inspection of aging aircraft: A manufacturer's perspective

    Science.gov (United States)

    Hagemaier, Donald J.

    1992-01-01

    Douglas, in conjunction with operators and regulators, has established interrelated programs to identify and address issues regarding inspection of aging aircraft. These inspection programs consist of the following: Supplemental Inspection Documents; Corrosion Prevention and Control Documents; Repair Assessment Documents; and Service Bulletin Compliance Documents. In addition, airframe manufacturers perform extended airframe fatigue tests to deal with potential problems before they can develop in the fleet. Lastly, nondestructive inspection (NDI) plays a role in all these programs through the detection of cracks, corrosion, and disbonds. However, improved and more cost effective NDI methods are needed. Some methods such as magneto-optic imaging, electronic shearography, Diffractor-Sight, and multi-parameter eddy current testing appear viable for near-term improvements in NDI of aging aircraft.

  19. In-service inspection guidelines for composite aerospace structures

    International Nuclear Information System (INIS)

    Heida, Jaap H.; Platenkamp, Derk J.

    2012-01-01

    The in-service inspection of composite aerospace structures is reviewed, using the results of a evaluation of promising, mobile non-destructive inspection (NDI) methods. The evaluation made use of carbon fibre reinforced specimens representative for primary composite aerospace structures, including relevant damage types such as impact damage, delaminations and disbonds. A range of NDI methods were evaluated such as visual inspection, vibration analysis, phased array ultrasonic inspection, shearography and thermography inspection. Important aspects of the evaluation were the capability for defect detection and characterization, portability of equipment, field of view, couplant requirements, speed of inspection, level of training required and the cost of equipment. The paper reviews the damage tolerance design approach for composites, and concludes with guidelines for the in-service inspection of composite aerospace structures.

  20. FBR metallic materials test manual (English version)

    International Nuclear Information System (INIS)

    Odaka, Susumu; Kato, Shoichi; Yoshida, Eiichi

    2003-06-01

    For the development of the fast breeder reactor, this manual describes the method of in-air and in-sodium material tests and the method of organization the data. This previous manual has revised in accordance with the revision of Japanese Industrial Standard (JIS) and the conversion to the international unit. The test methods of domestic committees such as the VAMAS (Versailles Project on Advanced Materials and Standards) workshop were also refereed. The material test technologies accumulated in this group until now were also incorporated. This English version was prepared in order to provide more engineers with the FBR metallic materials test manual. (author)

  1. Optimal allocation of international atomic energy agency inspection resources

    International Nuclear Information System (INIS)

    Markin, J.T.

    1987-01-01

    Each year the Department of Safeguards of the International Atomic Energy Agency (IAEA) conducts inspections to confirm that nuclear materials and facilities are employed for peaceful purposes. Because of limited inspection resources, however, the IAEA cannot fully attain its safeguards goals either quantitatively as measured by the inspection effort negotiated in the facility attachments or qualitatively as measured by the IAEA criteria for evaluating attainment of safeguards goals. Under current IAEA procedures the allocation of inspection resources assigns essentially equal inspection effort to facilities of the same type. An alternative approach would incorporate consideration of all material categories and facilities to be assigned inspection resources when allocating effort to a particular facility. One such method for allocating inspection resources is based on the IAEA criteria. The criteria provide a framework for allocating inspection effort that includes a ranking of material types according to their safeguards importance, an implicit definition of inspection activities for each material and facility type, and criteria for judging the attainment of safeguards goals in terms of the quality and frequency of these inspection activities. This framework is applicable to resource allocation for an arbitrary group of facilities such as a state's fuel cycle, the facilities inspected by an operations division, or all of the facilities inspected by the IAEA

  2. Wheel inspection system environment.

    Science.gov (United States)

    2008-11-18

    International Electronic Machines Corporation (IEM) has developed and is now marketing a state-of-the-art Wheel Inspection System Environment (WISE). WISE provides wheel profile and dimensional measurements, i.e. rim thickness, flange height, flange ...

  3. Integration of design and inspection

    Science.gov (United States)

    Simmonds, William H.

    1990-08-01

    Developments in advanced computer integrated manufacturing technology, coupled with the emphasis on Total Quality Management, are exposing needs for new techniques to integrate all functions from design through to support of the delivered product. One critical functional area that must be integrated into design is that embracing the measurement, inspection and test activities necessary for validation of the delivered product. This area is being tackled by a collaborative project supported by the UK Government Department of Trade and Industry. The project is aimed at developing techniques for analysing validation needs and for planning validation methods. Within the project an experimental Computer Aided Validation Expert system (CAVE) is being constructed. This operates with a generalised model of the validation process and helps with all design stages: specification of product requirements; analysis of the assurance provided by a proposed design and method of manufacture; development of the inspection and test strategy; and analysis of feedback data. The kernel of the system is a knowledge base containing knowledge of the manufacturing process capabilities and of the available inspection and test facilities. The CAVE system is being integrated into a real life advanced computer integrated manufacturing facility for demonstration and evaluation.

  4. Fuel inspection device

    International Nuclear Information System (INIS)

    Tsuji, Tadashi.

    1990-01-01

    The fuel inspection device of the present invention has a feature of obtaining an optimum illumination upon fuel rod interval inspection operation in a fuel pool. That is, an illumination main body used underwater is connected to a cable which is led out on a floor. A light control device is attached to the other end of the cable and an electric power cable is connected to the light control device. A light source (for example, incandescent lamp) is incorporated in the casing of the illumination main body, and a diffusion plate is disposed at the front to provide a plane light source. The light control device has a light control knob capable of remote-controlling the brightness of the light of the illumination main body. In the fuel inspection device thus constituted, halation is scarcely caused on the image screen upon inspection of fuels by a submerged type television camera to facilitate control upon inspection. Accordingly, efficiency of the fuel inspection can be improved to shorten the operation time. (I.S.)

  5. Enhancement of the reliability of automated ultrasonic inspections using tools of quantitative NDT

    International Nuclear Information System (INIS)

    Kappes, W.; Baehr, W.; Kroening, M.; Schmitz, V.

    1994-01-01

    To achieve reliable test results from automated ultrasonic inspection of safety related components, optimization and integral consideration of the various inspection stages - inspection planning, inspection performance and evaluation of results - are indispensable. For this purpose, a large potential of methods is available: advanced measurement techniques, mathematical-numerical modelling processes, artificial intelligence tools, data bases and CAD systems. The potential inherent in these methods to enhance inspection reliability is outlined by way of different applications. (orig.) [de

  6. Radiological Control Manual

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.

  7. EMSL Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Foster, Nancy S.

    2009-06-18

    This manual is a general resource tool to assist EMSL users and Laboratory staff within EMSL locate official policy, practice and subject matter experts. It is not intended to replace or amend any formal Battelle policy or practice. Users of this manual should rely only on Battelle’s Standard Based Management System (SBMS) for official policy. No contractual commitment or right of any kind is created by this manual. Battelle management reserves the right to alter, change, or delete any information contained within this manual without prior notice.

  8. EMSL Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Foster, Nancy S.

    2009-03-25

    This manual is a general resource tool to assist EMSL users and Laboratory staff within EMSL locate official policy, practice and subject matter experts. It is not intended to replace or amend any formal Battelle policy or practice. Users of this manual should rely only on Battelle’s Standard Based Management System (SBMS) for official policy. No contractual commitment or right of any kind is created by this manual. Battelle management reserves the right to alter, change, or delete any information contained within this manual without prior notice.

  9. Radiological Control Manual

    International Nuclear Information System (INIS)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records

  10. HASL procedures manual

    International Nuclear Information System (INIS)

    Harley, J.H.

    1977-08-01

    Additions and corrections to the following sections of the HASL Procedures Manual are provided: General, Sampling, Field Measurements; General Analytical Chemistry, Chemical Procedures, Data Section, and Specifications

  11. PCs The Missing Manual

    CERN Document Server

    Karp, David

    2005-01-01

    Your vacuum comes with one. Even your blender comes with one. But your PC--something that costs a whole lot more and is likely to be used daily and for tasks of far greater importance and complexity--doesn't come with a printed manual. Thankfully, that's not a problem any longer: PCs: The Missing Manual explains everything you need to know about PCs, both inside and out, and how to keep them running smoothly and working the way you want them to work. A complete PC manual for both beginners and power users, PCs: The Missing Manual has something for everyone. PC novices will appreciate the una

  12. Research on UAV Intelligent Obstacle Avoidance Technology During Inspection of Transmission Line

    Science.gov (United States)

    Wei, Chuanhu; Zhang, Fei; Yin, Chaoyuan; Liu, Yue; Liu, Liang; Li, Zongyu; Wang, Wanguo

    Autonomous obstacle avoidance of unmanned aerial vehicle (hereinafter referred to as UAV) in electric power line inspection process has important significance for operation safety and economy for UAV intelligent inspection system of transmission line as main content of UAV intelligent inspection system on transmission line. In the paper, principles of UAV inspection obstacle avoidance technology of transmission line are introduced. UAV inspection obstacle avoidance technology based on particle swarm global optimization algorithm is proposed after common obstacle avoidance technologies are studied. Stimulation comparison is implemented with traditional UAV inspection obstacle avoidance technology which adopts artificial potential field method. Results show that UAV inspection strategy of particle swarm optimization algorithm, adopted in the paper, is prominently better than UAV inspection strategy of artificial potential field method in the aspects of obstacle avoidance effect and the ability of returning to preset inspection track after passing through the obstacle. An effective method is provided for UAV inspection obstacle avoidance of transmission line.

  13. Requirements to be met by the operation manual

    International Nuclear Information System (INIS)

    1981-03-01

    The rule applies to the contents and the lay-out of the operating manual for stationary nuclear power plants. The draft contains: 1. General requirement to be met by the contents of the operating manual. The operating manual to be arranged in 4 parts (part 1: internal rules and regulations; part 2: operation overall plant; part 3: incidents; part 4: operation systems). Safety specifications to be included in the manual, the exemption being the system of technical documentation. 2. General requirements to be met by the lay-out of the operating manual. Comprehensibility; legibility; structure and subdivisions; arrangement of the instructions and design of the manuals cover. 3. Requirements to be met by part 1. Defining the various internal rules and regulations (personnel management); rules and regulations concerning inspections and shift work; maintenance and repair; radiation protection; guard duty and admission; alarm; fire protection; first aid. 4. Requirements to be met by part 2. Provisions and operational limitations; limit values important from the point of view of safety; normal operation; anomalous operation; in-service inspections. 6. Requirements to be met by part 3. 7. Annex: Rules, regulations and stipulations mentioned in the rule draft. (orig.)

  14. General inspection strategy for fault diagnosis-minimizing the inspection costs

    International Nuclear Information System (INIS)

    Reinertsen, Rune; Wang Xiaozhong

    1995-01-01

    In this paper, a general inspection strategy for system fault diagnosis is presented. The procedure presented in this paper, is an improvement of methods described in papers by , and . This general strategy provides the optimal inspection procedure when the inspections require unequal effort and the minimum cut set probabilities are unequal. This feature makes the procedure described in this paper more useful for practical applications than the most recent procedure presented in the paper by Najmus-Saqib and Ishaque, which requires the minimum cut set probabilities to be equal. The inspection strategy described in this paper is based on first inspecting the basic event that will provide the maximum information gain per unit cost invested. The information gain is measured by the decrease of Shannon entropy. A detailed tutorial example is presented

  15. Recent advances in automated ultrasonic inspection of Magnox power stations

    International Nuclear Information System (INIS)

    Wooldridge, A.B.

    2006-01-01

    Magnox Electric operates a number of Magnox nuclear power stations, some of which have presented difficult inspection challenges. This paper will describe recent advances in automated ultrasonic techniques which have enabled additional, fully effective and qualified inspections to be introduced. The examples chosen involve phased array inspection of fillet welds and the introduction of 3D data display and analysis using NDT Workbench. Ultrasonic phased arrays have been optimised for inspection of fillet welded structures where physical access for the operator is very awkward and the surfaces available for probe scanning are very restricted. In addition to controlling the beam direction and focus depth, the systems have also optimised the depth of field by varying the number of phased array elements fired at a given time. These phased array inspections are substantially superior in quality, reliability and speed compared with that achievable by conventional manual inspection. Analysis of automated ultrasonic data can be very time-consuming if defects are complex. NDT Workbench significantly improves data analysis for complex geometries and defects primarily because of the 3D data displays of multiple beams and automated logging of measurements. This system has been used in 2005 for data analysis of complex defects where sizing accuracy was particularly important. Both these inspection procedures have been formally qualified using the ENIQ (European Network for Inspection Qualification) Methodology. Such qualification was achieved more easily because of the rigorous in house training programmes established in each case and because the Technical Justifications referred to evidence from previous related qualifications whenever appropriate. The timely achievement of inspection qualification demonstrates that the new systems have reached sufficient maturity to be used with confidence for high quality inspections. (orig.)

  16. On the development of the METAR family of inspection tools

    Energy Technology Data Exchange (ETDEWEB)

    Lavoie, E. [Inst. de recherche d' Hydro-Quebec, Varennes, Quebec (Canada)]. E-mail: lavoie.eric@ireq.ca; Rousseau, G. [Hydro-Quebec, Central Nucleaire Gentilly-2, Gentilly, Quebec (Canada); Reynaud, L. [Inst. de recherche d' Hydro-Quebec, Varennes, Quebec (Canada)

    2003-07-01

    Since 1998, Hydro Quebec Research Centre (IREQ), in collaboration with Gentilly-2, has been working on the development of inspection devices for the feeder tubes of CANDU power plants. The first tool to come out of this work was the Metar bracelet, now used throughout the CANDU utilities, consisting of 14 ultrasonic probes held in place in a rigid bracelet to measure the thickness of the pipes and moved around manually along the pipe. Following the success of the Metar, a motorized version, i.e. the Crawler, has been developed to inspect beyond the operator arm's reach to access hard to reach place or further down the pipes in the reactor. This new system has been tested at 3 different stations and will be commercially available soon. Finally, the same technology was used to develop a motorized 2-axis crack detection device to answer new concerns about the feeder. Other configurations, depending on the demands from the industry, could also be developed for specific inspection needs, for example; inspection of the graylock welds, 360{sup o} inspection of feeders, or multitasking inspection on a single frame, etc. Most of the designs shown in this article have been or will be patented and are, or will be, licensed to a partner company to make them commercially available to the industry. This paper gives a brief history of the project and a description of the technologies developed in the last 5 years concerning feeder inspection. (author)

  17. Incore inspection device

    International Nuclear Information System (INIS)

    Ogisu, Tatsuki; Taguchi, Kosei.

    1995-01-01

    The device of the present invention can inspect surfaces of equipments in reactor water in a nuclear reactor in a state of atmospheric air. Namely, an inspection device is movable forwardly and backwardly in a water-proof vessel. An annular sucker with pleats is disposed to the outer side of a lid of the water-proof vessel. A television camera for an under water monitoring is disposed to the inner side of the lid of the water-proof vessel by way of a partitioning wall with lid. Transferring screws are disposed at the back and on the side of the water-proof vessel. In the device having such a constitution, (1) the inside of the water-proof vessel is at first made water-tight by closing the partitioning wall with lid, (2) the back and the side screws are operated by the guide of the underwater monitoring television camera, to transfer the water-proof vessel to the surface of the reactor core to be inspected, (3) the annular sucker with pleats is urged on the surface to be inspected by the back screw, to fix the water-proof vessel, (4) reactor water in a space of the annular sucker with pleats is discharged and replaced with air, and (5) the lid of the partition wall with lid is opened and the inspection device is disposed at a position of the underwater monitoring television camera, to inspect the surface to be inspected in a state of atmospheric air. (I.S.)

  18. Automated ultrasonic pipe weld inspection. Part 1

    International Nuclear Information System (INIS)

    Karl Deutsch, W.A.; Schulte, P.; Joswig, M.; Kattwinkel, R.

    2006-01-01

    This article contains a brief overview on automated ultrasonic welded inspection for various pipe types. Some inspection steps might by carried out with portable test equipment (e.g. pipe and test), but the weld inspection in all internationally relevant specification must be automated. The pipe geometry, the production process, and the pipe usage determine the number of required probes. Recent updates for some test specifications enforce a large number of ultrasonic probes, e.g. the Shell standard. Since seamless pipes are sometimes replaced by ERW pipes and LSAW pipes (in both cases to save production cost), the inspection methods change gradually between the various pipe types. Each testing system is unique and shows its specialties which have to be discussed by supplier, testing system user and final customer of the pipe. (author)

  19. Korean experience with steam turbine blade inspection

    International Nuclear Information System (INIS)

    Jung, Hyun Kyu; Park, D.Y.; Park, Hyung Jin; Chung, Min Hwa

    1990-01-01

    Several turbine blade accidents in Korea have emphasized the importance of their adequate periodic inspection. As a typical example, a broken blade was found in the Low Pressure (LP) turbine at the 950 MWe KORI unit 3 during the 1986 overhaul after one year commercial operation. Since then the Manufacturer and the Utility company (KEPCO) have been concerned about the need of blade root inspection. The ultrasonic testing was applied to detect cracks in the blade roots without removing the blades from rotor. Due to the complex geometry of the roots, the test results could not be evaluated easily. We feel that the currently applied UT technique seems to be less reliable and more effective method of inspection must be developed in the near future. This paper describes the following items: The causes and analysis of blade damage The inspection techniques and results The remedial action to be taken (Repair and Replacement) The future plan

  20. Automated reticle inspection data analysis for wafer fabs

    Science.gov (United States)

    Summers, Derek; Chen, Gong; Reese, Bryan; Hutchinson, Trent; Liesching, Marcus; Ying, Hai; Dover, Russell

    2009-04-01

    To minimize potential wafer yield loss due to mask defects, most wafer fabs implement some form of reticle inspection system to monitor photomask quality in high-volume wafer manufacturing environments. Traditionally, experienced operators review reticle defects found by an inspection tool and then manually classify each defect as 'pass, warn, or fail' based on its size and location. However, in the event reticle defects are suspected of causing repeating wafer defects on a completed wafer, potential defects on all associated reticles must be manually searched on a layer-by-layer basis in an effort to identify the reticle responsible for the wafer yield loss. This 'problem reticle' search process is a very tedious and time-consuming task and may cause extended manufacturing line-down situations. Often times, Process Engineers and other team members need to manually investigate several reticle inspection reports to determine if yield loss can be tied to a specific layer. Because of the very nature of this detailed work, calculation errors may occur resulting in an incorrect root cause analysis effort. These delays waste valuable resources that could be spent working on other more productive activities. This paper examines an automated software solution for converting KLA-Tencor reticle inspection defect maps into a format compatible with KLA-Tencor's Klarity Defect(R) data analysis database. The objective is to use the graphical charting capabilities of Klarity Defect to reveal a clearer understanding of defect trends for individual reticle layers or entire mask sets. Automated analysis features include reticle defect count trend analysis and potentially stacking reticle defect maps for signature analysis against wafer inspection defect data. Other possible benefits include optimizing reticle inspection sample plans in an effort to support "lean manufacturing" initiatives for wafer fabs.