WorldWideScience

Sample records for inr cyclotron

  1. Status of neutron complex of INR RAS

    Energy Technology Data Exchange (ETDEWEB)

    Grachev, M I; Koptelov, E A; Kravchuk, L V; Matveev, V A; Perekrestenko, A D; Sidorkin, S F [Institute for Nuclear Research of Russian Academy of Sciences, Prospekt, Moscow (Russian Federation); Stavissky, Y Y

    2001-03-01

    The neutron complex of INR RAS consists of two sources of neutrons, beam stop, lead slowing down spectrometer and solid state spectrometers. The description of objects and their condition, the program of planned researches, co-operation with other institutes of the Moscow Region, progress reached for last two years are introduced in the article. (author)

  2. Status of neutron complex of INR RAS

    International Nuclear Information System (INIS)

    Grachev, M.I.; Koptelov, E.A.; Kravchuk, L.V.; Matveev, V.A.; Perekrestenko, A.D.; Sidorkin, S.F.; Stavissky, Y.Y.

    2001-01-01

    The neutron complex of INR RAS consists of two sources of neutrons, beam stop, lead slowing down spectrometer and solid state spectrometers. The description of objects and their condition, the program of planned researches, co-operation with other institutes of the Moscow Region, progress reached for last two years are introduced in the article. (author)

  3. Medical Cyclotrons

    Science.gov (United States)

    Friesel, D. L.; Antaya, T. A.

    Particle accelerators were initially developed to address specific scientific research goals, yet they were used for practical applications, particularly medical applications, within a few years of their invention. The cyclotron's potential for producing beams for cancer therapy and medical radioisotope production was realized with the early Lawrence cyclotrons and has continued with their more technically advanced successors — synchrocyclotrons, sector-focused cyclotrons and superconducting cyclotrons. While a variety of other accelerator technologies were developed to achieve today's high energy particles, this article will chronicle the development of one type of accelerator — the cyclotron, and its medical applications. These medical and industrial applications eventually led to the commercial manufacture of both small and large cyclotrons and facilities specifically designed for applications other than scientific research.

  4. Superconducting cyclotrons

    International Nuclear Information System (INIS)

    Blosser, H.G.; Johnson, D.A.; Burleigh, R.J.

    1976-01-01

    Superconducting cyclotrons are particularly appropriate for acceleration of heavy ions. A review is given of design features of a superconducting cyclotron with energy 440 (Q 2 /A) MeV. A strong magnetic field (4.6 tesla average) leads to small physical size (extraction radius 65 cm) and low construction costs. Operating costs are also low. The design is based on established technology (from present cyclotrons and from large bubble chambers). Two laboratories (in Chalk River, Canada and in East Lansing, Michigan) are proceeding with construction of full-scale prototype components for such cyclotrons

  5. Cyclotrons: 1978

    International Nuclear Information System (INIS)

    Martin, J.A.

    1978-01-01

    A compilation is presented of the experimental facilities of the world's cyclotrons including history and status, staff and operation, research staff, target facilities, magnet, acceleration system, vacuum system, characteristic beams, beam properties, and a plan view of the facility for each cyclotron

  6. INR calibration of Owren-type prothrombin time based on the relationship between PT% and INR utilizing normal plasma samples.

    Science.gov (United States)

    Lindahl, Tomas L; Egberg, Nils; Hillarp, Andreas; Ødegaard, Ole R; Edlund, Bror; Svensson, Jan; Sandset, Per M; Rånby, Mats

    2004-06-01

    Prothrombin time (PT) is clinically important and is used to monitor oral anticoagulant therapy. To obtain PT results in international normalized ratio (INR), the current standardization procedure is complex and involves reference reagents. The PT of diluted plasma samples can be determined with a combined thromboplastin (the Owren-type procedure), but not necessarily with a plain thromboplastin (the Quick-type procedure). Owren-type PT procedures can therefore, as an alternative to the INR calibration, be calibrated with diluted normal plasma to give PT results in percent of normal PT activity (PT%). The present study explored if a plasma-based calibration of an Owren-type PT procedure can be used to obtain results in INR. The approach was to establish a relationship between PT% and INR by multi-center analysis of 365 samples from healthy individuals and patients on warfarin treatment. INR values were obtained by manual Quick-type reference procedure and PT% values by various automated Owren-type procedures. A relationship INR = (1/PT% + 0.018)/0.028 was found. A calibration procedure, based on the relationship, was investigated. Calibrators were the median PT of 21 normal plasma at dilutions representing 100%, 50%, 25%, 12.5% and 6.25% of normal PT activity. These were assigned INR values of 1.00, 1.36, 2.07, 3.05 and 6.36. Calibration of various Owren-type assays was repeatedly performed by 5 expert laboratories during 3 consecutive years. The INR values of certain lyophilised or frozen control plasmas were determined. The frozen control plasmas had externally assigned INR values according to WHO guide-lines. Within the laboratory, CV was typically below 3%. No appreciable difference among the results of the different laboratories or the three assay occasions was found. Externally assigned and INR values were essentially identical to those found. These and other results indicated that the calibration procedure was reproducible, precise and accurate. Thus, an

  7. LEPI - INR Pitesti. Achievements and prospects

    International Nuclear Information System (INIS)

    Gentea, Cristian; Parvan, Marcel; Tuturici, Ioan Liviu

    2002-01-01

    The Post-Irradiation Examination Laboratory, LEPI, of the Institute for Nuclear Research at Pitesti, Romania was designed and realized in the period 1977 - 1984. It is devoted to the nuclear activities of reception, manipulation, storing, processing, and examination of the radiation sources of high intensities, particularly irradiated nuclear materials and spent nuclear fuels. These materials result from the irradiation process taking place in the INR materials testing reactors and/or from the Cernavoda NPP. The examination implies nondestructive and destructive testing, followed by mechanical or chemical processing and allows physico-chemical and mechanical characterization, information needed to determine the behavior and operational performance in normal a hypothetically accidental operation conditions. The laboratory is provided with a set of hot chambers, transfer and examination cells suitable for working high activities, up to 1 MCi (37 PBq). The transfer cell is equipped with to working stations while the examinations cell has seven working stations. Each working station is equipped with a SOVIS window, a pair of HWM-A100 remote manipulators and several ducts for int/ext connections. The underpressurized inner air is filtered by a double battery of absolute serial filters with a 99.9% retaining efficiency for radioactive air sols with particles of sizes larger then 0.3 μm. The post irradiation examination comprises the following operations: transport; reception; visual inspection; dimensional control; high resolution gamma spectrometry; inflammable element marking; mounting and processing of the samples, mechanical testing to stretching; ceramographic and/or metallographic analysis by optical microscopy; radiochemical analysis, collecting, conditioning and intermediate storage of the process waste (residuals from spent fuel or irradiate materials); collecting, sorting and conditioning of the technological wastes (decontaminations materials, maintenance

  8. Using subcontractors: the experience of IRSN and INRS

    International Nuclear Information System (INIS)

    Jeffroy, Francois; Hery, Michel

    2014-01-01

    This article discusses the current status and assessment of risks and opportunities associated with subcontracting in nuclear installations as perceived and addressed by the IRSN (Institut de Radioprotection et de Surete Nucleaire) and the INRS (Institut National de Recherche et de Securite). A first part recalls how these issues have been addressed since the 1990's. The author notices that subcontracting is associated with different terminologies for the IRSN and the INRS. In the next part, the author discusses the debate about subcontracting. He outlines that the organisation of the client must be examined, notably with respect to safety, to the way ability and traceability of subcontractor activities are considered and addressed. He comments the relationships between the client and its subcontractors. He briefly comments how the IRSN and the INRS address differently these issues related to subcontracting

  9. Medical cyclotrons

    International Nuclear Information System (INIS)

    Wolf, A.P.

    1976-01-01

    Cyclotrons as tools for therapy and for the production of radionuclides for use in nuclear medicine have been extensively reviewed in the literature. The current world status with respect to cyclotrons used primarily for research, development and application in nuclear medicine is reviewed here in the context of geographical distribution and type of use, presently available commercial types, machine characteristics and trends. Aspects of design requirements from a user perspective such as machine, beam and target characteristics are covered. Some special problems concerning many factors which can lead to effective production of the desired radionuclide or product are considered in light of machine characteristics. Consideration is also given to future directions for accelerators in nuclear medicine

  10. Derived release limits for airborne effluents at TRIGA - INR Reactor

    International Nuclear Information System (INIS)

    Toma, A.; Dulama, C.; Hirica, O.; Mihai, S.; Oprea, I.

    2008-01-01

    Beginning from fulfilling the purposes of dose limitation system recommended by ICRP, and now accepted in radiation protection, this paper presents an environmental transfer model to calculate derived release limits for airborne and gaseous radioactive effluents at TRIGA-INR, 14 MW Steady State Reactor, in function on INR-Pitesti site. The methodology consists in determination of the principal exposure pathways for different groups of population and dose calculations for each radionuclide. The characterization of radionuclides transfer to environment was made using the compartmental model. The parameter transfer concept was used to describe the distribution of radionuclides between the different compartments. Atmospheric dispersion was very carefully treated, because it is the primary mechanism of the transfer of radionuclides in the environment and it determines all exposure pathways. Calculation of the atmospheric dispersion was made using ORION-II computer code based on the Gaussian plume model which takes account of site's specific climate and relief conditions. Default values recommended by literature were used to calculate some of the parameters when specific site values were not available. After identification of all transfer parameters which characterize the most important exposure pathways, the release rate corresponding to the individual dose rate limit was calculated. This maximum release rate is the derived release limit for each radionuclide and source. In the paper, the derived release limits are calculated for noble gases, radioiodine and other airborne particulate radionuclides, which can be released on the TRIGA-INR reactor stack, and are important to radiation protection. (authors)

  11. The prothrombin time/international normalised ratio (PT/INR) line: derivation of local INR with commercial thromboplastins and coagulometers – two independent studies

    DEFF Research Database (Denmark)

    Poller, Leon; Ibrahim, S.; Keown, M.

    2011-01-01

    reagents, and from 7.0% to 2.6% with rabbit reagents. In the second study, deviation was reduced from 11.2% to 0.4% with human reagents by both local ISI calibration and the PT/INR Line. With rabbit reagents, 10.4% deviation was reduced to 1.1% with both procedures; 4.9% deviation was reduced to 0.5......Background: The WHO scheme for prothrombin time (PT) standardization has been limited in application, because of its difficulties in implementation, particularly the need for mandatory manual PT testing and for local provision of thromboplastin international reference preparations (IRP). Methods...... thromboplastins and coagulometers. INRs were compared with manual certified values with thromboplastin IRP from expert centres and in the second study also with INRs from local ISI calibrations. Results: In the first study with the PT/INR Line, 8.7% deviation from certified INRs was reduced to 1.1% with human...

  12. Electromagnetic cyclotron harmonic waves

    International Nuclear Information System (INIS)

    Ohnuma, T.; Watanabe, T.; Hamamatsu, K.

    1981-09-01

    Electromagnetic electron cyclotron harmonic waves just below the electron cyclotron harmonics are investigated numerically and experimentally. Backward waves which are observed to propagate nearly perpendicular to the magnetic field just below the electron cyclotron frequency in a high density magnetoplasma are confirmed to be in accord with the theoretical electromagnetic cyclotron waves. (author)

  13. Vitamin K antagonist use: evidence of the difficulty of achieving and maintaining target INR range and subsequent consequences

    OpenAIRE

    Schein, Jeff R.; White, C. Michael; Nelson, Winnie W.; Kluger, Jeffrey; Mearns, Elizabeth S.; Coleman, Craig I.

    2016-01-01

    Vitamin K antagonists (VKAs) are effective oral anticoagulants that are titrated to a narrow therapeutic international normalized ratio (INR) range. We reviewed published literature assessing the impact of INR stability - getting into and staying in target INR range - on outcomes including thrombotic events, major bleeding, and treatment costs, as well as key factors that impact INR stability. A time in therapeutic range (TTR) of ?65?% is commonly accepted as the definition of INR stability. ...

  14. Patient-Specific Tailored Intervention Improves INR Time in Therapeutic Range and INR Variability in Heart Failure Patients.

    Science.gov (United States)

    Gotsman, Israel; Ezra, Orly; Hirsh Raccah, Bruria; Admon, Dan; Lotan, Chaim; Dekeyser Ganz, Freda

    2017-08-01

    Many patients with heart failure need anticoagulants, including warfarin. Good control is particularly challenging in heart failure patients, with range, thereby increasing the risk of complications. This study aimed to evaluate the effect of a patient-specific tailored intervention on anticoagulation control in patients with heart failure. Patients with heart failure taking warfarin therapy (n = 145) were randomized to either standard care or a 1-time intervention assessing potential risk factors for lability of INR, in which they received patient-specific instructions. Time in therapeutic range (TTR) using Rosendaal's linear model was assessed 3 months before and after the intervention. The patient-tailored intervention significantly increased anticoagulation control. The median TTR levels before intervention were suboptimal in the interventional and control groups (53% vs 45%, P = .14). After intervention the median TTR increased significantly in the interventional group compared with the control group (80% [interquartile range, 62%-93%] vs 44% [29%-61%], P <.0001). The intervention resulted in a significant improvement in the interventional group before versus after intervention (53% vs 80%, P <.0001) but not in the control group (45% vs 44%, P = .95). The percentage of patients with a TTR ≥60%, considered therapeutic, was substantially higher in the interventional group: 79% versus 25% (P <.0001). The INR variability (standard deviation of each patient's INR measurements) decreased significantly in the interventional group, from 0.53 to 0.32 (P <.0001) after intervention but not in the control group. Patient-specific tailored intervention significantly improves anticoagulation therapy in patients with heart failure. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Nuclear fuel manufacturing. Current activities and prospects at INR Pitesti

    International Nuclear Information System (INIS)

    Horhoianu, Grigore

    2001-01-01

    Development of the CANDU nuclear fuel is currently conducted world wide onto two principal directions: - increasing the service span of the current type of fuel and improving the efficiency of burnup in reactor; - reducing the costs of fuel manufacturing by improving the design and manufacturing technologies in condition of increasing fuel performance. In parallel, a research program, RAAN, is undergoing, concerning the development of advanced CANDU type fuels (SEU, RU, DUPIC, Th), aiming at reducing the overall costs per fuel cycle. In the INR TRIGA reactor a large number of experimental fuel elements manufactured in INR were irradiated under different conditions specific to the CANDU reactor operation. Post irradiation investigations both destructive and non-destructive were carried out in the hot cells at INR Pitesti. The experimental results were used in order to optimize and evaluate the fuel project, to check the fuel manufacturing technologies as well as to certify the computational codes. The local thermo-mechanical analyses by final element methods, modelling the SCC phenomenon, probabilistic evaluation of performance parameters of the fuel, constitute new directions in the modelling and developing computational code. The developed codes were submitted to a thorough validation process to comply with the quality assurance. The excellent results obtained in INR were confirmed by participation in the FUMEX International Exercises of computer code intercomparison, organized by IAEA Vienna. Progress was also recorded in establishing the behaviour of fuel elements failed during reactor operation and the effect their maintenance in the reactor core could have upon the power reactor operation. A system-expert variant was worked out able for a short term analysis of the decisions referring to removing the failing element at Cernavoda NPP. As advanced CANDU fuel is concerned, until now preliminary variants for a fuel bundle with 43 elements containing slightly

  16. The Automatic Radiation Control System Of The Inr Linear Accelerator (troitsk).

    CERN Document Server

    Grachev, M I; Kuptsov, S I; Peleshko, V N; Shishkin, K I; Shmelev, M O; Skorkin, V M

    2004-01-01

    The radiation monitor system (RMS) at accelerator INR is a part of radiation safety system of experimental complex INR. RMS is intended for continuous monitoring of radiation field behind biological protection of linear accelerator INR with the personnel dose control and alarm purposes. Three-level system RMS consists of the operator computer, microprocessor data acquisition modules and networks of UDBN-02R neutron detectors and BDRC-01P photon detectors, located inside and behind biological protection of the accelerator (fig. 1).

  17. Eleven years of net network research activity - inr contributions

    International Nuclear Information System (INIS)

    Deaconu, V.; Ionita, I.; Meleg, T.; Deaconu, M.; Truta, C.; Oncioiu, G.

    2013-01-01

    The European Network on Neutron Techniques Standardization for Structural Integrity (NeT) was established in 2002, grouping institutions from industry, research and academic media. Coordinated by the European Commission.s Joint Research Centre, the main mission of this network is to develop experimental and numerical techniques and standards for the reliable characterisation of residual stresses in structural welds. Each problem is tackled by creating a dedicated Task Group which manages measurement and modelling round robin studies and undertakes a thorough analysis and interpretation of the results. Over forty institutions are active NeT partners, their specific involvement and contributions being summarised in this paper. The Institute for Nuclear Research Pitesti (INR) is one of NeT founders and its contribution is related to numerical modelling, specimen analysis, material characterisation, data analysis or SANS support. This is also emphasised throughout this paper, together with the specific NeT research topics presentation. (authors)

  18. Waste processing practices at waste management department from INR

    International Nuclear Information System (INIS)

    Bujoreanu, D.; Bujoreanu, L.

    2010-01-01

    The Institute for Nuclear Research Pitesti (INR), subsidiary of the Romanian Authority for Nuclear Activities has its own Radioactive Waste Treatment Plant (STDR). The object of activity of STDR within the INR Pitesti is to treat and condition radioactive waste resulted from the nuclear facility. Also, it will must prepare and manage the decommissioning projects of its own facilities and to upgrade the facilities for the management of the radioactive waste resulting from other decommissioning activities. In according with the National Nuclear Program and the Governmental order no. 11/2003, the Institute for Nuclear Research is the main support for implementation of the methods and technologies for conditioning and disposal of radioactive waste generated by the decommissioning of nuclear facilities. The classes and criteria of classification for radioactive waste generated in operation and decommissioning in Romania are established in compliance with the classification recommended by IAEA and generally valid in EU countries. The general classification takes into consideration the disposal requirements to isolate the radioactive waste from environment. In Romania, waste minimization is considered by Order No. 56/2004 of CNCAN President for approval of Fundamental regulations on the safe management of radioactive waste. According to this regulation, the generation of radioactive waste is to be kept to the minimum practicable level in terms of both its activity and volume through appropriate design measures, facility operation and decommissioning practices. In order to meet this requirement, the operator must ensure: - selection and control of materials; - recycling and reuse of materials, including clearance of materials; - implementing adequate operating procedures, including those referring to the physical, chemical and radiological characterization of the waste and sorting of different type of materials. (orig.)

  19. Cyclotrons as mass spectrometers

    International Nuclear Information System (INIS)

    Clark, D.J.

    1984-04-01

    The principles and design choices for cyclotrons as mass spectrometers are described. They are illustrated by examples of cyclotrons developed by various groups for this purpose. The use of present high energy cyclotrons for mass spectrometry is also described. 28 references, 12 figures

  20. Performance evaluation of the microINR® point-of-care INR-testing system.

    Science.gov (United States)

    Joubert, J; van Zyl, M C; Raubenheimer, J

    2018-04-01

    Point-of-care International Normalised Ratio (INR) testing is used frequently. We evaluated the microINR ® POC system for accuracy, precision and measurement repeatability, and investigated instrument and test chip variability and error rates. Venous blood INRs of 210 patients on warfarin were obtained with Thromborel ® S on the Sysmex CS-2100i ® analyser and compared with capillary blood microINR ® values. Precision was assessed using control materials. Measurement repeatability was calculated on 51 duplicate finger-prick INRs. Triplicate finger-prick INRs using three different instruments (30 patients) and three different test chip lots (29 patients) were used to evaluate instrument and test chip variability. Linear regression analysis of microINR ® and Sysmex CS2100i ® values showed a correlation coefficient of 0.96 (P < .0001) and a positive proportional bias of 4.4%. Dosage concordance was 93.8% and clinical agreement 95.7%. All acceptance criteria based on ISO standard 17593:2007 system accuracy requirements were met. Control material coefficients of variation (CV) varied from 6.2% to 16.7%. The capillary blood measurement repeatability CV was 7.5%. No significant instrument (P = .93) or test chip (P = .81) variability was found, and the error rate was low (2.8%). The microINR ® instrument is accurate and precise for monitoring warfarin therapy. © 2017 John Wiley & Sons Ltd.

  1. Cyclotron waves in plasma

    International Nuclear Information System (INIS)

    Lominadse, D.G.

    1975-01-01

    The book deals with fundamental physical concepts of the theory of cyclotron waves and cyclotron instabilities conditioned by the presence in plasma of direct or alternating electric currents passing in it perpendicularily to a magnetic field. A great variety of problems is considered connected with the linear theory of cyclotron oscillations in equilibrium and electron plasma of metals and semiconductors. Parametric excitations of electron cyclotron oscillations of plasma in an alternating electric field are studied. Particular attention is paid to the investigation of plasma turbulence arising as a result of development of cyclotron instabilities. Experimental data are discussed and compared with theoretical results

  2. Cyclotron waves in plasma

    CERN Document Server

    Lominadze, D G

    2013-01-01

    Cyclotron Waves in Plasma is a four-chapter text that covers the basic physical concepts of the theory of cyclotron waves and cyclotron instabilities, brought about by the existence of steady or alternating plasma currents flowing perpendicular to the magnetic field.This book considers first a wide range of questions associated with the linear theory of cyclotron oscillations in equilibrium plasmas and in electron plasmas in metals and semiconductors. The next chapter deals with the parametric excitation of electron cyclotron oscillations in plasma in an alternating electric field. A chapter f

  3. Medical applications of cyclotrons

    International Nuclear Information System (INIS)

    Jean, R.; Fauchet, M.

    1978-01-01

    Isochronous cyclotrons used to accelerate different charged particles (protons, deuterons, alphas...) at variable energies, have important medical applications, for neutron teletherapy, in vivo or in vitro activation analysis or production of short-lived radioisotopes for nuclear medicine. The characteristics of the cyclotron presently available are described for these three applications (low energy 'compact' cyclotrons, cyclotrons of intermediate and high energies), and their advantages are discussed from the points of view of the medical requirements, the financial investments and the results obtained. (orig.) [de

  4. MICHIGAN: Cyclotron conference

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    A sense of excitement was in the air as cyclotron physicists and engineers from 17 countries convened on 30 April for the opening of the Tenth International Conference on Cyclotrons and Their Applications. Some 50 years after its invention, the redoubtable cyclotron remains a topic of compelling current interest. Cyclotron experts gathered at Michigan State University's Kellogg Center to hear of latest developments, of progress and successes on new machines which had come into operation, of new projects which were underway, and of dreams which lay ahead

  5. MICHIGAN: Cyclotron conference

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1984-10-15

    A sense of excitement was in the air as cyclotron physicists and engineers from 17 countries convened on 30 April for the opening of the Tenth International Conference on Cyclotrons and Their Applications. Some 50 years after its invention, the redoubtable cyclotron remains a topic of compelling current interest. Cyclotron experts gathered at Michigan State University's Kellogg Center to hear of latest developments, of progress and successes on new machines which had come into operation, of new projects which were underway, and of dreams which lay ahead.

  6. [Cyclotron based nuclear science

    International Nuclear Information System (INIS)

    1989-06-01

    This report contains papers on the following topics: Heavy ion reactors, nuclear structure and fundamental interactions; atomic and materials studies; nuclear theory; and superconducting cyclotron and instrumentation

  7. INR Recent Contributions to Thorium-Based Fuel Using in CANDU Reactors

    International Nuclear Information System (INIS)

    Prodea, I.; Mărgeanu, C. A.; Rizoiu, A.; Olteanu, G.

    2014-01-01

    The paper summarizes INR Pitesti contributions and latest developments to the Thorium-based fuel (TF) using in present CANDU nuclear reactors. Earlier studies performed in INR Pitesti revealed the CANDU design potential to use Recovered Uranium (RU) and Slightly Enriched Uranium (SEU) as alternative fuels in PHWRs. In this paper, we performed both lattice and CANDU core calculations using TF, revealing the main neutron physics parameters of interest: k-infinity, coolant void reactivity (CVR), channel and bundle power distributions over a CANDU 6 reactor core similar to that of Cernavoda, Unit 1. We modelled the so called Once Through Thorium (OTT) fuel cycle, using the 3D finite-differences DIREN code, developed in INR. The INR flexible SEU-43 bundle design was the candidate for TF carrying. Preliminary analysis regarding TF burning in CANDU reactors has been performed using the finite differences 3D code DIREN. TFs showed safety features improvement regarding lower CVRs in the case of fresh fuel use. Improvements added to the INR ELESIMTORIU- 1 computer code give the possibility to fairly simulate irradiation experiments in INR TRIGA research reactor. Efforts are still needed in order to get better accuracy and agreement of simulations to the experimental results. (author)

  8. Medical cyclotron facilities

    International Nuclear Information System (INIS)

    1984-09-01

    This report examines the separate proposals from the Austin Hospital and the Australian Atomic Energy Commission for a medical cyclotron facility. The proponents have argued that a cyclotron facility would benefit Australia in areas of patient care, availability and export of radioisotopes, and medical research. Positron emission tomography (PET) and neutron beam therapy are also examined

  9. 20 years Rossendorf cyclotron

    International Nuclear Information System (INIS)

    1978-08-01

    On the occasion of the 20th anniversary of initiating of the Rossendorf cyclotron accounts are given of most important works and results in the field of accelerator engineering and utilization of this machine. The reports show the trend of development and actual spectrum of application. The enclosed literature lists give a survey of technical and experimental works at cyclotron. (author)

  10. Vancouver Cyclotron Conference

    International Nuclear Information System (INIS)

    Clark, David J.

    1993-01-01

    Although no longer on the high energy frontier, the cyclotron field is still a major scientific growth area. Its progress is highlighted at the international conference on cyclotron design, development and utilization held at intervals of about three years, under the auspices of the International Union of Pure and Applied Physics (IUPAP). Vancouver, surrounded by mountains, water and some cyclotrons, provided a pleasant setting for the 13th Conference, held last summer. With over 200 cyclotrons in operation around the world, the attendance, 241 delegates and 26 industrial exhibitors, was a near record, reflecting the flourishing state of the field. The early sessions covered the initial operation of new or upgraded cyclotron facilities. Major facilities completed since the previous Conference in Berlin in May 1989 included the 400 MeV ring cyclotron at Osaka, the U400M cyclotron at Dubna which will be coupled to the U400 to give 20 MeV nucléon uranium beams, the 130 MeV cyclotron at Jyvaskyla (in Finland, the furthest north!), the 110 MeV JAERI machine in Japan, and the 65 MeV proton therapy cyclotron in Nice. Among the facility upgrades were the KFA cyclotron at Julich which will inject the 2.5 GeV storage ring COSY, and the addition of an FM mode to the K=200 CW mode at Uppsala to give protons up to 180 MeV. The impressive current of 1.5 mA at 72 MeV obtained from the PSI Injector II will soon be injected into the 590 MeV ring

  11. Cyclotrons for isotope production

    International Nuclear Information System (INIS)

    Milton, B.F.; Stevenson, N.R.

    1995-06-01

    Cyclotrons continue to be efficient accelerators for radioisotope production. In recent years, developments in the accelerator technology have greatly increased the practical beam current in these machines while also improving the overall system reliability. These developments combined with the development of new isotopes for medicine and industry, and a retiring of older machines indicates a strong future for commercial cyclotrons. In this paper we will survey recent developments in the areas of cyclotron technology, and isotope production, as they relate to the new generation of commercial cyclotrons. We will also discuss the possibility of systems capable of extracted energies up to 100 MeV and extracted beam currents of up to 2.0 mA. (author). 6 refs., 2 tabs., 3 figs

  12. Synchro-cyclotron

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    The electromagnetic coil which forms the first section of the proton extraction channel in the improved synchro-cyclotron. The photograph shows the positioning gear and the current septum. An extraction efficiency above 50% is expected.

  13. INR targets and site-level anticoagulation control: results from the Veterans AffaiRs Study to Improve Anticoagulation (VARIA).

    Science.gov (United States)

    Rose, A J; Berlowitz, D R; Miller, D R; Hylek, E M; Ozonoff, A; Zhao, S; Reisman, J I; Ash, A S

    2012-04-01

    Not all clinicians target the same International Normalized Ratio (INR) for patients with a guideline-recommended target range of 2-3. A patient's mean INR value suggests the INR that was actually targeted. We hypothesized that sites would vary by mean INR, and that sites of care with mean values nearest to 2.5 would achieve better anticoagulation control, as measured by per cent time in therapeutic range (TTR). To examine variations among sites in mean INR and the relationship with anticoagulation control in an integrated system of care. We studied 103,897 patients receiving oral anticoagulation with an expected INR target between 2 and 3 at 100 Veterans Health Administration (VA) sites from 1 October 2006 to 30 September 2008. Key site-level variables were: proportion near 2.5 (that is, percentage of patients with mean INR between 2.3 and 2.7) and mean risk-adjusted TTR. Site mean INR ranged from 2.22 to 2.89; proportion near 2.5, from 30 to 64%. Sites' proportions of patients near 2.5, below 2.3 and above 2.7 were consistent from year to year. A 10 percentage point increase in the proportion near 2.5 predicted a 3.8 percentage point increase in risk-adjusted TTR (P < 0.001). Proportion of patients with mean INR near 2.5 is a site-level 'signature' of care and an implicit measure of targeted INR. This proportion varies by site and is strongly associated with site-level TTR. Our study suggests that sites wishing to improve TTR, and thereby improve patient outcomes, should avoid the explicit or implicit pursuit of non-standard INR targets. © 2012 International Society on Thrombosis and Haemostasis.

  14. Vitamin K antagonist use: evidence of the difficulty of achieving and maintaining target INR range and subsequent consequences.

    Science.gov (United States)

    Schein, Jeff R; White, C Michael; Nelson, Winnie W; Kluger, Jeffrey; Mearns, Elizabeth S; Coleman, Craig I

    2016-01-01

    Vitamin K antagonists (VKAs) are effective oral anticoagulants that are titrated to a narrow therapeutic international normalized ratio (INR) range. We reviewed published literature assessing the impact of INR stability - getting into and staying in target INR range - on outcomes including thrombotic events, major bleeding, and treatment costs, as well as key factors that impact INR stability. A time in therapeutic range (TTR) of ≥65 % is commonly accepted as the definition of INR stability. In the real-world setting, this is seldom achieved with standard-of-care management, thus increasing the patients' risks of thrombotic or major bleeding events. There are many factors associated with poor INR control. Being treated in community settings, newly initiated on a VKA, younger in age, or nonadherent to therapy, as well as having polymorphisms of CYP2C9 or VKORC1, or multiple physical or mental co-morbid disease states have been associated with lower TTR. Clinical prediction tools are available, though they can only explain <10 % of the variance behind poor INR control. Clinicians caring for patients who require anticoagulation are encouraged to intensify diligence in INR management when using VKAs and to consider appropriate use of newer anticoagulants as a therapeutic option.

  15. The state of the art of the tacit knowledge transfer and preservation in INR

    International Nuclear Information System (INIS)

    Balaceanu, V.; Constantin, M.; Apostol, M.

    2008-01-01

    This paper intends to highlight the stringency that the nuclear knowledge, mainly the tacit one, must be transferred and preserved and, also, the appropriate methods and tools to perform it should be identified, selected and developed. The paper shows a detailed analysis of the state of the nuclear knowledge in INR. The starting point in this work were two investigations: a questionnaire-based investigation regarding the motivations of the INR retiring experts for knowledge transfer and preservation and an IAEA general questionnaire applied in INR. The necessity of a such analysis is motivated by the fact that in the next 5-10 years many experienced researchers should be retired and the INR staff must very quickly find the best methods and tools for an optimal transfer and preservation of the knowledge, mainly the tacit one because this is embedded in experts' minds. One of the most important conclusion of this analysis is that a short-medium term strategy must be developed, regarding the knowledge management. (authors)

  16. Participation of INR to the research project initiated by the CANDU Owners Group - Canada

    International Nuclear Information System (INIS)

    Roth, Maria; Ciocanescu, Marin; Gheorghiu, C-tin; Ohai, Dumitru; Visinescu, Doru; Ionescu, Silviu; Man, Ion; Pitigoi, Vasile; Anghel, Dumitru; Uta, Octavian

    2004-01-01

    Having in view the participation of the INR's Nuclear Materials and Corrosion Departments together with Chalk River Laboratories, AECL, and other nine well known institutes, to the Research Project coordinated by the International Atomic Energy Agency - Vienna and the results obtained as well, the CANDU Owners Group (COG) - Canada has proposed an economical contract to INR - Pitesti, called the DHC Project. The goal of this project was the investigation of the slow cracking in the hydration state (Delayed Hydride Cracking phenomenon) of the pressure tubes in CANDU reactors. There were determined, in specific conditions, the DHC rate, V DHC , and threshold factor of triggering the phenomenon K HI (the factor of stress intensity in the crack) occurring in un-irradiated Zr-2.5%Nb alloy. Further extensions of the project to irradiated alloys of the pressure tubes used in CANDU reactors, provided by the Canadian partner, are planned. This paper gives an overview covering the contributions of the INR's departments to the contract provisions for the current year as concluded with COG - Canada. It is described the design and execution activity of a device for processing the samples subject to testing, the mounting of the measuring chain, developing of a system for monitoring the testing parameters, the acquisition and automated processing of experimental data up to constituting the final report. The testing report was appreciated by the COG and recognized as demonstrating the INR's capability to fulfil the tasks of the DHC Project and so opened the way to further cooperation

  17. INR TRIGA Research Reactors: A Neutron Source for Radioisotopes and Materials Investigation

    International Nuclear Information System (INIS)

    Barbos, D.; Ciocanescu, M.; Paunoiu, C.; Bucsa, A.F.

    2013-01-01

    At the INR there are 2 high intensity neutron sources. These sources are in fact the two nuclear TRIGA reactors: TRIGA SSR 14 MW and TRIGA ACPR. TRIGA stationary reactor is provided with several in-core irradiation channels. Other several out-of-core irradiation channels are located in the vertical channels in the beryllium reflector blocks. The maximum value of the thermal neutron flux (E 14 cm -2 s -1 and of fast neutron flux (E>1 MeV) is 6.89×10 13 cm -2 s -1 . For neutron activation analysis both reactors are used and k0-NAA method has been implemented. At INR Pitesti a prompt gamma ray neutron activation analysis devices has been designed, manufactured ant put into operation. For nuclear materials properties investigation neutron radiography methods was developed in INR. For these purposes two neutron radiography devices were manufacture, one of them underwater and other one dry. The neutron beams are used for investigation of materials properties and components produced or under development for applications in the energy sector (fission and fusion). At TRIGA 14 MW reactor a neutron difractormeter and a SANS devices are available for material residual stress and texture measurements. TRIGA 14 MW reactor is used for medical and industrial radioisotopes production ( 131 I, 125 I, 192 Ir, etc) and a method for 99 Mo- 99 Tc production from fission is under developing. At INR Pitesti several special programmes for new types of nuclear fuel behavior characterization are under development. (author)

  18. Slow wave cyclotron maser

    International Nuclear Information System (INIS)

    Kho, T.H.; Lin, A.T.

    1988-01-01

    Cyclotron masers such as Gyrotrons and the Autoresonance Masers, are fast wave devices: the electromagnetic wave's phase velocity v rho , is greater than the electron beam velocity, v b . To be able to convert the beam kinetic energy into radiation in these devices the beam must have an initial transverse momentum, usually obtained by propagating the beam through a transverse wiggler magnet, or along a nonuniform guide magnetic field before entry into the interaction region. Either process introduces a significant amount of thermal spread in the beam which degrades the performance of the maser. However, if the wave phase velocity v rho v b , the beam kinetic energy can be converted directly into radiation without the requirement of an initial transverse beam momentum, making a slow wave cyclotron maser a potentially simpler and more compact device. The authors present the linear and nonlinear physics of the slow wave cyclotron maser and examine its potential for practical application

  19. Cyclotron to Oslo University

    International Nuclear Information System (INIS)

    Sandstad, J.

    1978-01-01

    The new cyclotron was delivered to Oslo University on September 21st 1978, and was mannfactured by A/B Scandtronix of Uppsala, Sweden. The contract price was 6,8 million Norwegian kroner and installation will cost a further 4 million. The main specifications are given. The energy will be 36 MeV for protons and alpha particles, 18 MeV deuterons and 48 MeV for helium 3. The principle of a cyclotron is briefly described. While the primary purpose of the machine is nuclear research it is also planned to produce short-lived radioisotopes, primarily iodine 123. (JIW)

  20. How cyclotrons work

    International Nuclear Information System (INIS)

    Nolan, D.

    1992-01-01

    The operating principles of a cyclic accelerator are presented based on the IBA Cyclone 30 negative ion cyclotron, selected for the Australia's first medical cyclotron. Its main features are: acceleration with variable energy of between 15-30 million electron volts, the capability of extracting two beams simultaneously, low power consumption, easy maintenance. Other aspects not directly related to the principle of operation discussed include the vacuum and the radio-frequency systems as well as the complex computerized control system used to automatically control start-up and shut-down operations. ills

  1. National Medical Cyclotron

    International Nuclear Information System (INIS)

    Boyd, Rex.

    1991-01-01

    The National Medical Cyclotron, under construction at Sydney's Royal Prince Alfred Hospital(RPAH) is to be operated by the Australian Nuclear Science and Technology Organization in collaboration with the hospital. Its main purpose is to produce radioisotopes on commercial basis for distribution to hospitals through Australia as well as short-lived radioisotopes (2 minutes to 2 hours) for immediate application at RPAH in Positron Emission Tomography, to study the dynamics of human physiology and metabolism in organs, bones and soft tissues. A list of the principal cyclotron-produced radionuclides is provided. ills

  2. Ramifide resonators for cyclotrons

    International Nuclear Information System (INIS)

    Smirnov, Yu.V.

    2000-01-01

    The resonators with the conductors ramified form for cyclotrons are systematized and separated into the self-contained class - the ramified resonators for cyclotrons (Carr). The ramified resonators are compared with the quarter-wave and half-wave nonramified resonators, accomplished from the transmitting lines fragments. The CRR are classified into two types: ones with the additional structural element, switched in parallel and in series. The CRR may include several additional structural elements. The CRR calculations may be concluded by analytical methods - the method of matrix calculation or the method of telegraph equations and numerical methods - by means of the ISFEL3D, MAFIA and other programs [ru

  3. Electron-Cyclotron Waves

    NARCIS (Netherlands)

    Westerhof, E.

    1994-01-01

    The essential elements of the theory of electron cyclotron waves are reviewed, The two main electro-magnetic modes of propagation are identified and their dispersion and absorption properties are discussed. The importance of the use of the relativistic resonance condition is stressed.

  4. Biomedical cyclotron facility

    International Nuclear Information System (INIS)

    MacDonald, N.S.; Birdsall, R.; Takahaski, J.; McConnel, L.; Wood, R.; Wakakuwa, S.

    1976-01-01

    During the fifth year of operation the mechanical performance of the cyclotron and accessory equipment was excellent. Major items put into operation were a small computer system interfaced with Ge-Li gamma spectrometer and a pneumatic-tube system for fast delivery of short-lived radionuclides. A table is presented listing the radionuclides produced

  5. Inaccuracy of INR measurements and suggestions for improved WHO guidelines for calibration of reference preparations – a statistical study

    DEFF Research Database (Denmark)

    Attermann, Jørn

    2003-01-01

    Numerous empirical studies show that the accuracy of international normalized ratio (INR) measurements is unsatisfactory and worse than generally expected. We demonstrate that a plausible reason for this large inaccuracy is a conventional calibration procedure of reference preparations with (i...... procedure also results in serious overestimation of the accuracy of INR measurements, thus leading to a false sense of security in oral anticoagulant therapy. In an example with data from WHO guidelines, we show that the systematic overprediction of INR (which is believed to be 0) may be as large as 5...

  6. Public expertise and crisis management: the contributions of the INRS and IRSN

    International Nuclear Information System (INIS)

    Supervil, Sylvie; Vaxelaire, Stephane

    2015-01-01

    The authors present and comment the main assets of the INRS (Institut national de recherche et de securite) and IRSN Institut de Radioprotection et de Surete Nucleaire), their common and specific concerns in the field of crisis management. The INRS possesses a diversity of abilities and professions (engineering, medicine, toxicology, ergonomics, etc.), resources adapted to the field of intervention of actors (work health services, local prevention services), the ability to intervene from the upstream knowledge of hazards to the proposition of solutions, the structures and availability to assist and support public authorities, and some practice outside a crisis context. On its side, the IRSN is a largely acknowledged expert, and participated to the elaboration of the national plan for the response to a major radiological or nuclear accident

  7. Effect of olanzapine treatment on INR of a patient receiving warfarin therapy

    Directory of Open Access Journals (Sweden)

    Derya Arslan

    2016-06-01

    Full Text Available Olanzapine is an atypical antipsychotic drug, commonly used in the management of psychotic symptoms in patients with schizoprenia and bipolar affective disorder. Deep venous thrombosis is a manifestation of venous thromboembolism. It is very well known that use of antipsychotic drugs increase the risk of thrombosis in a patient with schizophrenia. It has been reported in many studies the effects of olanzapine on thrombosis but there isn't any report about the effect of olanzapine on international normalized ratio (INR. in the medical literature. In this paper, a patient with schizophrenia and also family history of deep venous thrombosis who emerged deep venous thrombosis after being started on olanzapine treatment and effect of olanzapine treatment on INR has been reported. [Cukurova Med J 2016; 41(2.000: 370-373

  8. Precision of INR measured with a patient operated whole blood coagulometer

    DEFF Research Database (Denmark)

    Attermann, Jørn; Andersen, Niels Trolle; Korsgaard, Helle

    2003-01-01

    INTRODUCTION: The objective of the present study was to evaluate the precision of a portable whole blood coagulometer (CoaguChek S) in the hands of self-managing patients on oral anticoagulant therapy (OAT). MATERIALS AND METHODS: Fifteen patients on self-managed OAT performed measurements of INR...... and between patients was 15.0% and 14.7%, respectively. CONCLUSION: The precision of CoaguChek S is satisfactory....

  9. Determination of a safe INR for joint injections in patients taking warfarin.

    Science.gov (United States)

    Bashir, M A; Ray, R; Sarda, P; Li, S; Corbett, S

    2015-11-01

    With an increase in life expectancy in 'developed' countries, the number of elderly patients receiving joint injections for arthritis is increasing. There are legitimate concerns about an increased risk of thromboembolism if anticoagulation is stopped or reversed for such an injection. Despite being a common dilemma, the literature on this issue is scarce. We undertook 2,084 joint injections of the knee and shoulder in 1,714 patients between August 2008 and December 2013. Within this cohort, we noted 41 patients who were taking warfarin and followed them immediately after joint injection in the clinic or radiology department, looking carefully for complications. Then, we sought clinical follow-up, correspondence, and imaging evidence for 4 weeks, looking for complications from these joint injections. We recorded International Normalised Ratio (INR) values before injection. No complications were associated with the procedure after any joint injection. The radiologists who undertook ultrasound-guided injections to shoulders re-scanned the joints looking for haemarthroses: they found none. A similar outcome was noted clinically after injections in the outpatient setting. With a mean INR of 2.77 (range, 1.7-5.5) and a maximum INR within this group of 5.5, joint injections to the shoulder and knee can be undertaken safely in primary or secondary care settings despite the patient taking warfarin.

  10. Irradiation tests on PHWR type fuel elements in TRIGA research reactor of INR Pitesti

    Energy Technology Data Exchange (ETDEWEB)

    Horhoianu, Grigore [Institute for Nuclear Research, Pitesti (Romania). Nuclear Fuel Engineering Lab.; Sorescu, Ion [Institute for Nuclear Research, Pitesti (Romania). TRIGA Reactor Loop Facility; Parvan, Marcel [Institute for Nuclear Research, Pitesti (Romania). Hot Cells Lab.

    2012-12-15

    Nine PHWR type fuel elements with reduced length were irradiated in loop A of the TRIGA Research Reactor of INR Pitesti. The primary objective of the test was to determine the performance of nuclear fuel fabricated at INR Pitesti at high linear powers in pressurized water conditions. Six fuel elements were irradiated with a ramp power history, achieving a maximum power of 45 kW/m during pre-ramp and of 64 kW/m in the ramp. The maximum discharge burnup was of 216 MWh/kgU. Another three fuel elements with reduced length were irradiated with declining power history. At the beginning of irradiation the fuel elements achieved a maximum linear power of 66 kW/m. The maximum fuel power was about 1.3 times the maximum expected in PHWR. The maximum discharge burnup was 205 MWh/kgU. The elements were destructively examined in the hot cells of INR Pitesti. Temperature-sensitive parameters such as UO{sub 2} grain growth, fission-gas release and sheath deformations were examined. The tests proved the feasibility of irradiating PHWR type fuel elements at linear powers up to 66 kW/m under pressurized water conditions and demonstrated the possibility of more flexible operation of this fuel in power reactors. This paper presents the results of the investigation. (orig.)

  11. Use of an INR-style bunch-length detector in the Fermilab Linac

    International Nuclear Information System (INIS)

    McCrory, E.S.; Schmidt, C.W.; Feschenko, A.V.

    1993-01-01

    Device to accurately measure the phase extent of a linac beam is being developed for use in the Fermilab 400 MeV Linac Upgrade. Prototypes have been and are being tested. We have attempted to improve the original design from the Institute for Nuclear Research in Moscow (INR) to increase the resolution for adequate operation at 805 MHz. The device incorporating a new arrangement of lens and deflector, reported previously, cannot achieve the desired resolution. This paper describes the operation and the strengths and weaknesses of the three types of bunch-length detectors (BLDs) and the measurements made at this time. The differences among these devices is delineated by the relative position of the rf deflector and the electrostatic einsel lens, as follows: INR--Lens before deflector; Fermilab--Lens after deflector; H- beam; and FNAL/INR--Lens and deflector combined. To satisfy the goals of commissioning the new linac, a resolution of about 5 picoseconds (1 degree at 805 MHz) is desired

  12. Goodbye Synchro-Cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1990-12-15

    On 17 December, after having seen many other physics machines come and go during its 33-year career, CERN's 600 MeV SynchroCyclotron (SC) is being shut down. Judged simply by its length (to say nothing of its quality), the research career of this machine testifies to the wisdom and imagination of the CERN pioneers who proposed it in the early 1950s.

  13. Goodbye Synchro-Cyclotron

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    On 17 December, after having seen many other physics machines come and go during its 33-year career, CERN's 600 MeV SynchroCyclotron (SC) is being shut down. Judged simply by its length (to say nothing of its quality), the research career of this machine testifies to the wisdom and imagination of the CERN pioneers who proposed it in the early 1950s

  14. Cyclotrons in developing countries

    International Nuclear Information System (INIS)

    Vera Ruiz, Hernan

    2004-01-01

    Cyclotron accelerators are prolific sources of charged particle for the production of radionuclides and have become an essential tool in the practice of modern nuclear medicine by providing reliable radiotracers for SPECT and PET studies. In a recent survey conducted by the IAEA in 2001, the growth in the number of cyclotron facilities installed in laboratories and hospitals in developed as well as developing countries was recorded. This trend, which started in the late 70's, continues in the present time also and all indications are that it will continue in the next five to ten years. The reasons for this growth are several: technology involved has become more user or 'hospital friendly', third party reimbursement for several clinical studies based on F-18 PET radiopharmaceuticals at least in some of the advanced countries started in 1998 and above all, the clear irrefutable and demonstrable conclusion of the positive cost/benefit outcomes of PET studies in the field of oncology to a lesser degree, thus far, for cardiology and neurology. It is however recognizable that the overall financial cost of the technology, which comprises the premises to house the facility, the cyclotron accelerator, the corresponding radiochemistry and quality control equipment and the PET cameras can be nevertheless an expensive proposition that requires careful advance planning. This fact is even more relevant when the facility is planned for installation in a developing country, which, frequently, in addition to having a lack of sufficient financial resources, do have shortage of qualified human resources to efficiently run the facility. In spite of the above, it is fact that more and more public as well as private organizations in the developing countries are setting up cyclotron/PET programmes or are seriously considering the installation of such a facility

  15. Startup work on Inshas cyclotron

    International Nuclear Information System (INIS)

    Vorogushin, M.F.; Strokach, A.P.; Shikhov, V.Ya.; Galchuk, A.V.; Soliman, A.N.; El-Abyad, M.; Comsan, M.N.H.; Saleh, Z.A.; Azzam, A.N.

    2001-01-01

    Startup works on the MGC-20 variable energy cyclotron in the Inshas Nuclear Research Center (Egypt) are described. The cyclotron is intended for acceleration of hydrogen and helium ions in a wide energy range (for protons - from 5 to 20 MeV). Main units of the cyclotron and results of computer experimental acceleration of protons to 18 MeV are described. The prospects of furthers investigations are presented [ru

  16. Diagnostic and Therapeutic Yield of Endoscopy in Patients with Elevated INR and Gastrointestinal Bleeding.

    Science.gov (United States)

    Peloquin, Joanna M; Seraj, Siamak M; King, Lindsay Y; Campbell, Emily J; Ananthakrishnan, Ashwin N; Richter, James M

    2016-06-01

    Gastrointestinal bleeding is a well-known risk of systemic anticoagulation. However, bleeding in the setting of supratherapeutic anticoagulation may have a milder natural history than unprovoked bleeding. It is a common clinical gestalt that endoscopy is common, but bleeding source identification or intervention is uncommon, yet few data exist to inform this clinical impression. Consequently, we sought to examine our institutional experience with gastrointestinal bleeding in the setting of supratherapeutic international normalized ratio (INR) with the aim of identifying predictors of endoscopically identifiable lesions, interventions, and outcomes. A retrospective review was conducted at a tertiary referral academic medical center to identify patients presenting with gastrointestinal bleeding in the setting of warfarin and a supratherapeutic INR (>3.5) who underwent an endoscopic procedure. Relevant clinical covariates, endoscopic findings, need for intervention, and outcomes were collected by review of the medical record. Logistic regression adjusting for potential confounders identified predictors of endoscopically significant lesions as well as intervention and outcomes. A total of 134 patients with INR 3.5 or greater (mean 5.5, range 3.5-17.1) presented with symptoms of gastrointestinal bleeding, most commonly as melena or symptomatic anemia. Antiplatelet agents were used by 54% of patients, and 60% of patients were on concomitant acid suppression on admission. Procedures included esophagogastroduodenoscopy (upper endoscopy; EGD) (n = 128), colonoscopy (n = 73), and video capsule endoscopy (n = 32). Active bleeding at first EGD or colonoscopy was found in only 19 patients (18%), with endoscopic intervention in only 26 patients (25%). At a critical threshold of INR 7.5 at presentation, the likelihood of finding an endoscopically significant lesion fell to therapy (odds ratio [OR] 2.59; 95% confidence interval [CI], 1.13-5.94), timing of EGD within 12 hours of

  17. Ion cyclotron resonance heating

    International Nuclear Information System (INIS)

    Tajima, T.

    1982-01-01

    Ion cyclotron resonance heating of plasmas in tokamak and EBT configurations has been studied using 1-2/2 and 2-1/2 dimensional fully self-consistent electromagnetic particle codes. We have tested two major antenna configurations; we have also compared heating efficiencies for one and two ion species plasmas. We model a tokamak plasma with a uniform poloidal field and 1/R toroidal field on a particular q surface. Ion cyclotron waves are excited on the low field side by antennas parallel either to the poloidal direction or to the toroidal direction with different phase velocities. In 2D, minority ion heating (vsub(perpendicular)) and electron heating (vsub(parallel),vsub(perpendicular)) are observed. The exponential electron heating seems due to the decay instability. The minority heating is consistent with mode conversion of fast Alfven waves and heating by electrostatic ion cyclotron modes. Minority heating is stronger with a poloidal antenna. The strong electron heating is accompanied by toroidal current generation. In 1D, no thermal instability was observed and only strong minority heating resulted. For an EBT plasma we model it by a multiple mirror. We have tested heating efficiency with various minority concentrations, temperatures, mirror ratios, and phase velocities. In this geometry we have beach or inverse beach heating associated with the mode conversion layer perpendicular to the toroidal field. No appreciable electron heating is observed. Heating of ions is linear in time. For both tokamak and EBT slight majority heating above the collisional rate is observed due to the second harmonic heating. (author)

  18. Solid targetry for compact cyclotrons

    International Nuclear Information System (INIS)

    Comor, J.

    2004-01-01

    In this presentation authors present experimental results of solid targetry for compact cyclotrons. It is concluded: Solid targetry is not restricted to large accelerator centers anymore; Small and medium scale radioisotope production is feasible with compact cyclotrons; The availability of versatile solid target systems is expected to boost the radiochemistry of 'exotic' positron emitters

  19. Cyclotrons and positron emitting radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, A.P.; Fowler, J.S.

    1984-01-01

    The state of the art of Positron Emission Tomography (PET) technology as related to cyclotron use and radiopharmaceutical production is reviewed. The paper discusses available small cyclotrons, the positron emitters which can be produced and the yields possible, target design, and radiopharmaceutical development and application. 97 refs., 12 tabs. (ACR)

  20. Status report on cyclotron operation

    International Nuclear Information System (INIS)

    Kovacs, P.; Szuecs, I.; Ander, I.; Lakatos, T.; Fenyvesi, A.; Ditroi, F.; Takacs, S.; Tarkanyi, F.

    2004-01-01

    The operation of the cyclotron in 2003 was again concentrated to 9 months; January, July and August were reserved for maintenance, renewal works and holidays. The overall working time of the accelerator was 4051 hours. The cyclotron was available for users for 3682 hours. In order to improve the circumstances of the irradiations renewal and improvements were done. (N.T.)

  1. Cyclotrons and positron emitting radiopharmaceuticals

    International Nuclear Information System (INIS)

    Wolf, A.P.; Fowler, J.S.

    1984-01-01

    The state of the art of Positron Emission Tomography (PET) technology as related to cyclotron use and radiopharmaceutical production is reviewed. The paper discusses available small cyclotrons, the positron emitters which can be produced and the yields possible, target design, and radiopharmaceutical development and application. 97 refs., 12 tabs

  2. Medical cyclotron: why, where, how

    International Nuclear Information System (INIS)

    Scheer, Kurt; Comar, Dominique; Kellershohn, Claude

    1976-01-01

    Cyclotrons for medical purposes are particularly useful for the production of radioactive isotopes of elements normally constituting organic matter ( 15 O, 13 N, 11 C). The short half-life and positron emission of those elements are of great interest in medical diagnosis. Many others carrier-free radioisotopes can be produced by cyclotrons. Three categories of cyclotrons are mentioned. Desk top cyclotron only adapted to the production of short-lived radioisotopes in a hospital; low energy and average energy cyclotrons which require well-entrained personnel for their operation and are best adapted to the production of radioelements on a regional or even national scale. Examples relative to the interest of short-lived radioisotopes in lung and brain investigations and tumor detection are given

  3. Retrofitting the instrumentation and control system of primary cooling circuit from TRIGA INR 14 MW reactor

    International Nuclear Information System (INIS)

    Preda, M.; Ciocanescu, M.; Ana, E. M.; Cristea, D.

    2008-01-01

    Activities of retrofitting the instrumentation and control system from TRIGA INR primary cooling circuit consists in replacement of actual system for: - parameter measurement; - safety; - reactor external scramming; - protection, command and supply for electrical elements of the system. This retrofitting project is designed to ensure the necessary features of reactor external safety and for technological parameter measurement. The new safety system of main cooling circuit is completely separated from its operating system and is arranged in a panel assembly in reactor control room. The operating system has the following features: - data acquisition; - parameter value and state of command elements displaying; - command elements on hierarchical levels; - operator information through visual and acoustic alarm. (authors)

  4. JSW's baby cyclotron

    International Nuclear Information System (INIS)

    Toda, Y.; Kaneda, Y.; Satoh, Y.; Suzukawa, I.; Yamada, T.

    1983-01-01

    Designed by The Japan Steel Works, Ltd., specially for installation in a hospital's medical department and nuclear research laboratory, '' JSW BABY CYCLOTRON '' has been developed to produce short-lived radioisotopes such as 11C, 13N, 15O and 18F. JSW's Baby Cyclotron has some design features. 1) Fixed energy and four sector azimuthally varying field. 2) Compact figure desired for hospital's nuclear medical department 3) A bitter type magnet yoke shielding activity 4) Simple control and operation 5) Easy maintenance without skilled personnel. Type BC105 (P:10MeV, d:5MeV), BC107 (P:10MeV, d:7MeV), BC168 (P:16MeV, d:8MeV) and BC1710 (P:17MeV, d:10MeV) are available according to required amount of radioisotopes. In our radioisotope production test, yield and purity of 11C, 13N, 15O and 18F are usable to clinical diagnosis

  5. Cyclotron produced radiopharmaceuticals

    International Nuclear Information System (INIS)

    Kopicka, K.; Fiser, M.; Hradilek, P.; Hanc, P.; Lebeda, O.

    2003-01-01

    Some of the cyclotron-produced radionuclides may serve as important materials for the production of radiopharmaceuticals. This lecture deals with basic information relating to various aspects of these compounds. In comparison with radionuclides /compounds used for non-medical purposes, radiopharmaceuticals are subject to a broader scale of regulations, both from the safety and efficacy point of view; besides that, there are both radioactive and medical aspects that must be taken into account for any radiopharmaceutical. According to the regulations and in compliance with general rules of work with radioactivity, radiopharmaceuticals should only be prepared/manufactured under special conditions, using special areas and special equipment and applying special procedures (e.g. sterilisation, disinfection, aseptic work). Also, there are special procedures for cleaning and maintenance. Sometimes the requirements for the product safety clash with those for the safety of the personnel; several examples of solutions pertaining to these cases are given in the lecture. Also, the specific role of cyclotron radiopharmaceuticals is discussed. (author)

  6. Guidelines for certification of International Normalized Ratio (INR) for vitamin K antagonists monitoring according to the EN ISO 22870 standards.

    Science.gov (United States)

    Brionne-François, Marie; Bauters, Anne; Mouton, Christine; Voisin, Sophie; Flaujac, Claire; Le Querrec, Agnès; Lasne, Dominique

    2018-06-01

    Point of care testing (POCT) must comply with regulatory requirements according to standard EN ISO 22870, which identify biologists as responsible for POCT. INR for vitamin K antagonists (VKAs) monitoring is a test frequently performed in haemostasis laboratories. Bedside INR is useful in emergency room, in particular in case of VKAs overdosage but also for specific populations of patients like paediatrics or geriatrics. INR POCT devices are widely used at home by the patients for self-testing, but their use in the hospital by the clinical staff for bedside measurement is growing, with devices which now comply with standard for POCT accreditation for hospital use. The majority of point of care devices for INR monitoring has shown a good precision and accuracy with results similar to those obtained in laboratory. With the aim to help the multidisciplinary groups for POCT supervision, the medical departments and the biologists to be in accordance with the standard, we present the guidelines of the GFHT (Groupe français d'étude sur l'hémostase et la thrombose, subcommittee "CEC et biologie délocalisée") for the certification of POCT INR. These guidelines are based on the SFBC guidelines for the certification of POCT and on the analysis of the literature to ascertain the justification of clinical need and assess the analytical performance of main analysers used in France, as well as on a survey conducted with biologists.

  7. The use of vitamin K supplementation to achieve INR stability: a systematic review and meta-analysis.

    Science.gov (United States)

    Kramps, Melissa; Flanagan, Abigail; Smaldone, Arlene

    2013-10-01

    Systematically review and quantitatively synthesize evidence on use of oral vitamin K supplementation in reducing international normalized ratio (INR) variability. PubMed, The Cochrane Library, PsycINFO, Cumulative Index of Nursing and Allied Health Literature (CINAHL), Turning Research Into Practice (TRIP), Web of Science were searched for studies meeting predetermined inclusion/exclusion criteria. Five studies meeting criteria (three randomized trials, one quasi-experimental pre-post study, one retrospective case series) were appraised for quality and data synthesized by two reviewers. Pooled effect size of time in INR therapeutic range (TTR) was estimated using random effects meta-analysis. Pooled effect size representing data from four studies (678 subjects) was 0.31, 95% confidence interval 0.03-0.59 (Cochran Q = 7.1; p = .07; I(2) = 57.8) and favored vitamin K supplementation. Given wide variability among individual studies, there is not enough evidence to advise for or against the routine use of vitamin K supplementation to achieve INR stability. However, evidence does suggest that it may be of some benefit for some patients with INR instability. There is insufficient evidence to support routine supplementation with vitamin K in patients on chronic anticoagulation therapy but select patients, particularly those with persistent INR instability despite known adherence to regimen and no dietary or drug-drug interactions, may benefit from the intervention. Future research is warranted. ©2013 The Author(s) ©2013 American Association of Nurse Practitioners.

  8. Applied research with cyclotrons

    International Nuclear Information System (INIS)

    Apel, P.; Dmitriev, S.; Gulbekian, G.; Gikal, B.; Ivanov, O.; Reutov, V.; Skuratov, V.

    2005-01-01

    During the past three decades the Flerov laboratory carried out research and development of a number of applications that have found or may find use in modern technologies. One of the applications is the so-called ion track technology enabling us to create micro- and nano-structured materials. Accelerated heavy ion beams are the unique tools for structuring insulating solids in a controllable manner. At FLNR JINR the U-400 cyclotron and the IC-100 cyclotron are employed for irradiation of materials to be modified by the track-etch technique. For practical applications, U-400 delivers the 86 Kr ion beams with total energies of 250, 350, 430 and 750 MeV, and the 136 Xe ion beams with the energy of 430 MeV. The cyclotron is equipped with a specialized channel for irradiation of polymer foils. IC-100 is a compact accelerator specially designed for the technological uses. High-intensity krypton ion beams with the energy of ∼ 1 MeV/u are available now at IC-100. Production of track-etch membranes is an example of mature technology based on irradiation with accelerated ions. The track-etch membranes offer distinct advantages over other types of membranes due to their precisely determined structure. One-pore, oligo-pore and multi-pore samples can serve as models for studying the transport of liquids, gases, particles, solutes, and electrolytes in narrow channels. Track-etch pores are also used as templates for making nano wires, nano tubes or array of nano rods. The microstructures obtained this way may find use in miniaturized devices such as sensors for biologically important molecules. Bulk and surface modification for the production of new composites and materials with special optical properties can be performed with ion beams. Flexible printed circuits, high-performance heat transfer modules, X-ray filters, and protective signs are examples of products developed in collaboration with research and industrial partners. Some recent achievements and promising ideas that

  9. The environmental radioactivity data analysis at the inr platform in the post-chernobyl period

    International Nuclear Information System (INIS)

    Tudor, G.; Valeca, M.; Iordache, R.

    2016-01-01

    As a result of the Chernobyl accident, large quantities of radioactive substances were released into the atmosphere and were transported long distances, covering virtually the whole Europe, including Romania. This paper presents the analysis of the environment radioactivity data around the INR site, in the post-Chernobyl period in different types of samples. The purpose of this study was to evaluate the evolution of Chernobyl originated radionuclides concentration in Mioveni-Pitesti area. The selected indicator was Cs-137, which was monitored on a regular basis. From the post-Chernobyl annual reports, were collected the average values for Cs-137 activity in environmental samples. The concentration was determined for eleven sampling locations (soil and vegetation samples) distributed on 10 km distance around INR site, and the determination was made using gamma spectrometry. The data reveals significant variations of the Cs-137 activity. These variations may be generated by various disturbances that detach material from the soil and air, therefore allowing the substance to travel long distances from its origin. (authors)

  10. Isochronous cyclotron data base description

    International Nuclear Information System (INIS)

    Kiyan, I.N.; Vorozhtsov, S.B.; Tarashkevich, R.

    2004-01-01

    The relational data base of the control parameters of the isochronous cyclotron, Isochronous Cyclotron Data Base (ICDB), is described. The relational data base under consideration, written in Transact SQL for the MS SQL Server 2000 with the use of MS Enterprise Manager and MS Query Analyzer, was installed on the server of the AIC144 isochronous cyclotron in Krakow, which operates under the control of the operating system MS Windows Server 2003 (Standard Edition). The interface of the data base under considerations is written in C++ with the use of Visual C++ .NET and is built in the Cyclotron Operator Help Program (COHP), which is used for modeling the operational modes of the isochronous cyclotron. Communication between the COHP and the relational data base is realised on the base of the Open Data Base Connectivity protocol. The relational data base of the control parameter of the isochronous cyclotron is intended: firstly, for systematization and automatic use of all measured and modelled magnetic field maps in the process of modeling the operational modes; secondly, for systematization and convenient access to the stored operational modes; thirdly, for simplifying the operator's work. The relational data base of the control parameter of the isochronous cyclotron reflects its physical structure and the logic of its operator's work. (author)

  11. [Cyclotron based nuclear science

    International Nuclear Information System (INIS)

    1991-08-01

    This report contains descriptions of research programs carried out by Institute staff, as well as progress on new instrumentation during the period, April 1, 1990, to March 31, 1991. The K500 cyclotron and ECR source provided beam for 4140 hours during the period. The beam was actually available for experiments 1927.50 hours and 1110.50 hours was devoted to developing new beams and exploring cyclotron performance. A wide range of beams from protons to Xe with energies from 2.4 MeV/u to 60 MeV/U have been used in experiments. The highest total energy beam accelerated was 35 MeV/u 63 Cu. The ECR source, made a tremendous improvement in accelerator performance and reliability. Substantial amounts of beam time were devoted to investigations of hot nuclei, electron-positron, giant resonances, atomic effects of high velocity ion beams, astrophysics related reactions and proton and alpha bremsstrahlung. Scientific accomplishments included determination of the heat capacity of nuclei through new insight into the level densities and establishing a lower limit for electron positron resonances a factor of ten better than previous measurements. The proton spectrometer, constructed for studies of the Gamow-Teller interaction is complete, and initial physics measurements will be made in the next few months. All of the BaF 2 crystals have been delivered and acceptance tests are underway. A K=315 MDM spectrometer has been obtained from Oxford University and is scheduled for installation in Spring 1992, after removal of the K=150 Enge split pole spectrometer. Institute groups continue participation in MEGA, instrumentation projects for RHIC, and few nucleon studies at LAMPF and KEK. Reports of these activities are included

  12. Ion Cyclotron Resonance Facility (ICR)

    Data.gov (United States)

    Federal Laboratory Consortium — his facility is charged with developing and exploiting the unique capabilities of Fourier Transform Ion Cyclotron Resonance (FT-ICR) mass spectrometry, and leads the...

  13. Present and future superconducting cyclotrons

    International Nuclear Information System (INIS)

    Nolen, J.A. Jr.

    1987-01-01

    This paper begins with a brief review of the status of present superconducting (SC) cyclotron projects, including the two which are currently operating and the six which are under construction. The next section summarizes the main features shared by five of these machines, while the third section presents recent developments and new concepts introduced in the other three ''second generation'' SC cyclotrons. Projects in early stages of development are discussed in the fourth section

  14. Injection and extraction for cyclotrons

    International Nuclear Information System (INIS)

    Heikkinen, P.

    1994-01-01

    External ion sources for cyclotrons are needed for polarised and heavy ions. This calls for injection systems, either radial or axial. Radial injection is also needed when a cyclotron works as a booster after another cyclotron or a linear accelerator (usually tandem). Requirements for injection differ from separated sector cyclotrons where there is plenty of room to house inflectors and/or strippers, to superconducting cyclotrons where the space is limited by a small magnet gap, and high magnetic field puts other limitations to the inflectors. Several extraction schemes are used in cyclotrons. Stripping injection is used for H - and also for heavy ions where the q/m ratio is usually doubled. For other cases, electric and magnetic deflection has to be used. To increase the turn separation before the first deflector, both resonant and non-resonant schemes are used. In this lecture, external injection systems are surveyed and some rules to thumb for injection parameters are given. Extraction schemes are also reviewed. (orig.)

  15. Assessing Clinical Laboratory Quality: A College of American Pathologists Q-Probes Study of Prothrombin Time INR Structures, Processes, and Outcomes in 98 Laboratories.

    Science.gov (United States)

    Howanitz, Peter J; Darcy, Theresa P; Meier, Frederick A; Bashleben, Christine P

    2015-09-01

    The anticoagulant warfarin has been identified as the second most frequent drug responsible for serious, disabling, and fatal adverse drug events in the United States, and its effect on blood coagulation is monitored by the laboratory test called international normalized ratio (INR). To determine the presence of INR policies and procedures, INR practices, and completeness and timeliness of reporting critical INR results in participants' clinical laboratories. Participants reviewed their INR policies and procedure requirements, identified their practices by using a questionnaire, and studied completeness of documentation and timeliness of reporting critical value INR results for outpatients and emergency department patients. In 98 participating institutions, the 5 required policies and procedures were in place in 93% to 99% of clinical laboratories. Fifteen options for the allowable variations among duplicate results from different analyzers, 12 different timeliness goals for reporting critical values, and 18 unique critical value limits were used by participants. All required documentation elements were present in 94.8% of 192 reviewed INR validation reports. Critical value INR results were reported within the time frame established by the laboratory for 93.4% of 2604 results, but 1.0% of results were not reported. Although the median laboratories successfully communicated all critical results within their established time frames and had all the required validation elements based in their 2 most recent INR calculations, those participants at the lowest 10th percentile were successful in 80.0% and 85.7% of these requirements, respectively. Significant opportunities exist for adherence to INR procedural requirements and for practice patterns and timeliness goals for INR critical results' reporting.

  16. Inre och yttre motivation till träning : en kvalitativ studie bland regebundet aktiva kvinnor

    OpenAIRE

    Jonsson, Johanna

    2015-01-01

    Bakgrund: Regelbunden träning är viktig för både fysiskt och psykisktvälbefinnande. För att bibehålla en regelbundenhet i träningen krävs det ettengagemang och en motivation. En person kan motiveras av både inre ochyttre faktorer beroende på personens intresse. Trots att människor tenderaratt vara mer stillasittande, tycks intresset för träning och hälsa öka. Inteminst syns detta på sociala medier, där bilder och inlägg medträningsbudskap förmedlas frekvent. Syfte: Studiens syfte är att under...

  17. Multicavity proton cyclotron accelerator

    Directory of Open Access Journals (Sweden)

    J. L. Hirshfield

    2002-08-01

    Full Text Available A mechanism for acceleration of protons is described, in which energy gain occurs near cyclotron resonance as protons drift through a sequence of rotating-mode TE_{111} cylindrical cavities in a strong nearly uniform axial magnetic field. Cavity resonance frequencies decrease in sequence from one another with a fixed frequency interval Δf between cavities, so that synchronism can be maintained between the rf fields and proton bunches injected at intervals of 1/Δf. An example is presented in which a 122 mA, 1 MeV proton beam is accelerated to 961 MeV using a cascade of eight cavities in an 8.1 T magnetic field, with the first cavity resonant at 120 MHz and with Δf=8 MHz. Average acceleration gradient exceeds 40 MV/m, average effective shunt impedance is 223 MΩ/m, but maximum surface field in the cavities does not exceed 7.2 MV/m. These features occur because protons make many orbital turns in each cavity and thus experience acceleration from each cavity field many times. Longitudinal and transverse stability appear to be intrinsic properties of the acceleration mechanism, and an example to illustrate this is presented. This acceleration concept could be developed into a proton accelerator for a high-power neutron spallation source, such as that required for transmutation of nuclear waste or driving a subcritical fission burner, provided a number of significant practical issues can be addressed.

  18. Tachyonic cyclotron radiation

    International Nuclear Information System (INIS)

    Tomaschitz, R.

    2006-01-01

    We study superluminal cyclotron emission by electrons and muons in semiclassical orbits. The tachyonic line spectra of hydrogenic ions such as H, 56 Fe 25+ , and 238 U 91+ , as well as their muonic counterparts pμ - , 56 Fe 26+ μ - and 238 U 92+ μ - are calculated, in particular the tachyonic power transversally and longitudinally radiated, the total intensity, and the power radiated in the individual harmonics. We also investigate tachyonic continuum radiation from electrons and protons cycling in the surface and light cylinder fields of γ -ray and millisecond pulsars, such as the Crab pulsar, PSR B1509-58, and PSR J0218 + 4232. The superluminal spectral densities generated by non-relativistic, mildly relativistic and ultra-relativistic source particles are derived. We study the parameters determining the global shape of the transversal and longitudinal densities and the energy scales of the broadband spectrum. The observed cutoff frequency in the γ-ray band of the pulsars is used to infer the upper edge of the orbital energy, and we conclude that electrons and nuclei cycling in the surface fields can reach energies beyond the ''ankle'' of the cosmic ray spectrum. This suggests γ-ray pulsars as sources of ultra-high energy cosmic rays. (orig.)

  19. INR participation in the IAEA research project investigating the influence of hydrogen absorption on zirconium alloy behavior

    International Nuclear Information System (INIS)

    Roth, Maria; Radu, Vasile; Dobrea, Dumitru; Pitigoi, Vasile

    2003-01-01

    The paper summarizes the results obtained at INR Pitesti from its participation in the research project coordinated by IAEA Vienna in cooperation with Chalk River and AECL Canada, titled 'Hydrogen and Hydride Induced Degradation of the Mechanical and Physical Properties of Zirconium-based Alloys'. Evidenced is the contribution of INR Pitesti in the works of this project as well as the benefits of this participation for Romania as owner of CANDU type reactor. In the frame this project new results concerning the propagation rate of DHC type cracks in pressure tubes in CANDU reactors were obtained. The same method used to investigate the DHC project was adapted for determination of other quantities of interest related to structural integrity of the materials. The methodology was applied for testing the pressure tubes in Cernavoda NPP Unit 1. The contribution of INR team to statistical processing of data obtained in all the laboratories participating in this project is also highlighted. Opportunity afforded by IAEA to INR Pitesti to bring its contribution to the development of this project of international cooperation together with other well-known institutions and the support from RAAN are acknowledged. These opened ways for other fruitful international cooperation

  20. [Knockdown of InR gene in ventral nephrocytes promotes resistance to toxic stress in Drosophila melanogaster females].

    Science.gov (United States)

    Andreenkova, O V; Karpova, E K; Menshanov, P N; Rauschenbach, I Yu

    2015-02-01

    Hemolymph filtration in insects is performed by nephrocytes, additional cells of the circulatory system that are not connected to Malpighian vessels. Drosophila has two types of nephrocytes: the ventral ("garland"), which are situated around the connection site of the esophagus and proventriculus, and the pericardial, which are localized around the heart. In this study, we examined the role of the of insulin-like receptor (InR)gene in regulation of the function of ventral nephrocytes (VNC) in D. melanogaster females. Immunofluorescent analysis of female VNC with anti-InR antibodies revealed for the first time that the InR gene is expressed in VNC cells. To determine whether a change in the level of InR expression has an effect on VNC function in Drosophila females, we implemented an antisense suppressor of the InR gene, together with a driver that is expressed specifically in VNC. VNC function was evaluated by survival of the females exposed to toxic stress (treatment with AgNO3). This study has shown for the first time that suppression of InR expression in VNC leads to a rise in the survival of flies under conditions of toxic stress.

  1. [Cyclotron based nuclear science

    International Nuclear Information System (INIS)

    1993-07-01

    The period 1 April 1992--31 March 1993 saw the initial runs of three new spectrometers, which constitute a major portion of the new detection capabilities developed for this facility. These devices are the Proton Spectrometer (PSP) (data from which are shown on the cover of this document), the Mass Achroniat Recoil Mass Spectrometer (MARS), and the Multipole Dipole Multipole (MDM) Particle Spectrometer. The ECR-K500 cyclotron combination operated 5,849 hours. The beam was on target 39% of this time. Studies of nuclear dynamics and nuclear thermodynamics using the neutron ball have come to fruition. A critical re-evaluation of the available data on the giant monopole resonance indicated that the incompressibility is not specified to a range smaller than 200--350 MeV by those data. New systematic experiments using the MDM spectrometer are now underway. The MEGA collaboration obtained the first data on the μ → eγ decay rate and determination of the Michel parameter in normal μ decay. Experiments appear to confirm the existence of monoenergetic pair peaks even for relatively low Z projectile -- Z target combinations. Studies of the (α,2α) knockout reaction indicate that this reaction may prove to be a valuable tool for determination of reaction rates of astrophysical interest. Theoretical work reported in this document ranges from nuclear structure calculations using the IBM-2 model to calculations of kaon production and the in-medium properties of the rho and phi mesons. Nuclear dynamics and exotic shapes and fragmentation modes of hot nuclei are also addressed. New measurements of x-ray emission from highly ionized ions, of molecular dissociation and of surface interactions are reported. The research is presented in nearly 50 brief summaries usually including data and references

  2. Electron cyclotron harmonic wave acceleration

    Science.gov (United States)

    Karimabadi, H.; Menyuk, C. R.; Sprangle, P.; Vlahos, L.

    1987-01-01

    A nonlinear analysis of particle acceleration in a finite bandwidth, obliquely propagating electromagnetic cyclotron wave is presented. It has been suggested by Sprangle and Vlahos in 1983 that the narrow bandwidth cyclotron radiation emitted by the unstable electron distribution inside a flaring solar loop can accelerate electrons outside the loop by the interaction of a monochromatic wave propagating along the ambient magnetic field with the ambient electrons. It is shown here that electrons gyrating and streaming along a uniform, static magnetic field can be accelerated by interacting with the fundamental or second harmonic of a monochromatic, obliquely propagating cyclotron wave. It is also shown that the acceleration is virtually unchanged when a wave with finite bandwidth is considered. This acceleration mechanism can explain the observed high-energy electrons in type III bursts.

  3. Electron cyclotron harmonic wave acceleration

    International Nuclear Information System (INIS)

    Karimabadi, H.; Menyuk, C.R.; Sprangle, P.; Vlahos, L.; Salonika Univ., Greece)

    1987-01-01

    A nonlinear analysis of particle acceleration in a finite bandwidth, obliquely propagating electromagnetic cyclotron wave is presented. It has been suggested by Sprangle and Vlahos in 1983 that the narrow bandwidth cyclotron radiation emitted by the unstable electron distribution inside a flaring solar loop can accelerate electrons outside the loop by the interaction of a monochromatic wave propagating along the ambient magnetic field with the ambient electrons. It is shown here that electrons gyrating and streaming along a uniform, static magnetic field can be accelerated by interacting with the fundamental or second harmonic of a monochromatic, obliquely propagating cyclotron wave. It is also shown that the acceleration is virtually unchanged when a wave with finite bandwidth is considered. This acceleration mechanism can explain the observed high-energy electrons in type III bursts. 31 references

  4. Present situation of 'baby cyclotron'

    International Nuclear Information System (INIS)

    Yamada, Teruo

    1981-01-01

    A ''baby cyclotron'' has been developed by the Japan Steel Works, Ltd. Its No. 1 model (proton 9.4 MeV) was delivered to the Nakano Hospital of National Sanatorium in March, 1979. It is being used successfully for the production of 11 C, 13 N and 15 O and labeled compounds. The proton or deuteron particles accelerated in the cyclotron collide on target materials. The target box, which is automatically changeable, is directly installed to the accelerating box, thereby taking the safety measures for any leaking radiation. The following matters are described: the production of short-lived radioisotopes (RI yields and treatment); the processes of production in the Nakano Hospital, with No. 1 baby cyclotron, including the photosynthesis of labeled compounds such as 11 C-labeled glucose; the research on the automation in the synthesis of organic labeled compounds like 11 C-palmitic acid. (J.P.N.)

  5. Status Report on Cyclotron Operation

    International Nuclear Information System (INIS)

    Kovacs, P.; Szuecs, I.; Ander, I.; Lakatos, T.; Tarkanyi, F.

    2004-01-01

    Complete text of publication follows. The operation of the cyclotron in 2004 was concentrated to the usual 9 months; January, July and August were reserved for maintenance and holidays. The overall working time of the accelerator was 3554 hours, the time used for systematic maintenance was 450 hours. The breakdown periods amounted to 70 hours last year, included in it a 50 hours repair of RF control module under guarantee. The cyclotron was available for users during 3034 hours. The effectively used beam-on-target time statistics is summarized in Table 1. Developments: A new measuring site with a HPGe detector based gamma spectrometer is under installation in the basement of the Cyclotron Laboratory. A two channel pneumatic rabbit system is also under development to enable fast transport of samples between the new measuring site and two irradiation sites (the low intensity fast neutron irradiation site and the beam line used for Thin Layer Activation). (author)

  6. Development of Medical Cyclotron in KIRAMS

    International Nuclear Information System (INIS)

    Chai, Jong Seo; Jung, In Su; An, Dong Hyun

    2005-01-01

    This paper is presented on the development and status of medical cyclotron at the Korea Institute of Radiological and Medical Sciences (KIRAMS) at present. We have developed medical cyclotron which is KIRAMS-13. And the improvement of KIRAMS-13 is presented. Furthermore, the design of new cyclotrons, such as KIRAMS-5 and KIRAMS-30 cyclotron, are presented, and R and D studies for future plan of heavy ion accelerator are discussed

  7. MC-50 AVF cyclotron operation

    Energy Technology Data Exchange (ETDEWEB)

    Chae, Jong Seo; Lee, Dong Hoon; Kim, You Seok; Park, Chan Won; Lee, Yong Min; Hong, Sung Seok; Lee, Min Yong

    1995-12-01

    The first cyclotron in Korea, MC-59 cyclotron is used for neutron irradiation, radionuclide development, production and material and biomedical research. 50.5MeV and 35MeV proton beam have been extracted with 20-70 .mu.A. A total of beam extraction time are 1095.7 hours. 206.5 hours are used for the developments and 663.8 hours are for radionuclide production and development and 225.4 hours for application researches. The shutdown days are 23days. Fundamental data for failure decrement and efficient beam extraction were composed and maintenance technologies were developed. (author). 8 tabs., 17 figs., 10 refs.

  8. MC-50 AVF cyclotron operation

    International Nuclear Information System (INIS)

    Kim, Yu Seok; Chai, Jong Seo; Bak, Seong Ki; Park, Chan Won; Jo, Young Ho; Hong, Seong Seok; Lee, Min Yong; Jang Ho Ha

    2000-01-01

    The first cyclotron in Korea, MC-50 cyclotron is used for neutron irradiation, radionuclide development, production and material and biomedical research. 50.5MeV and 35MeV proton beam have been extracted with 20-60μA. A total of beam extraction time are 1095.7 hours. 206.5 hours are used for the developments and 663.8 hours are for radionuclide production and development and 225.4 hours for application researches. The shutdown days are 23 days. Fundamental data for failure decrement and efficient beam extraction were composed and maintenance technologies were developed

  9. MC-50 AVF cyclotron operation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yu Seok; Chai, Jong Seo; Bak, Seong Ki; Park, Chan Won; Jo, Young Ho; Hong, Seong Seok; Lee, Min Yong; Jang Ho Ha

    2000-01-01

    The first cyclotron in Korea, MC-50 cyclotron is used for neutron irradiation, radionuclide development, production and material and biomedical research. 50.5MeV and 35MeV proton beam have been extracted with 20-60{mu}A. A total of beam extraction time are 1095.7 hours. 206.5 hours are used for the developments and 663.8 hours are for radionuclide production and development and 225.4 hours for application researches. The shutdown days are 23 days. Fundamental data for failure decrement and efficient beam extraction were composed and maintenance technologies were developed.

  10. The development of cyclotron radiopharmaceuticals

    International Nuclear Information System (INIS)

    Yang, Seung Dae; Chun, K. W.; Suh, Y. S.; Lee, J. D.; Ahn, S. H. and others

    1999-03-01

    The purpose of this project is to develop the radiopharmaceuticals and automatic synthetic unit for labelled compounds, and to establish mass production system of radiopharmaceuticals. These will contribute to the early diagnosis of the disease hard to cure. The contents of this project are as follows, the development of the radiopharmaceutical for imaging of cancer, the development of automatic synthesizer for the synthesis of radio-pharmaceuticals, the development of hormone derivatives labelled with 12 '3I, the development of the radiopharmaceuticals for therapy of cancer labelled with cyclotron produced radionuclides, the development of radiopharmaceuticals for therapy of cancer labelled with cyclotron produced radionuclides, the development of radiopharmaceuticals for imaging of myocardial metabolism

  11. MC-50 AVF cyclotron operation

    International Nuclear Information System (INIS)

    Chae, Jong Seo; Lee, Dong Hoon; Kim, You Seok; Park, Chan Won; Lee, Yong Min; Hong, Sung Seok; Lee, Min Yong.

    1995-12-01

    The first cyclotron in Korea, MC-59 cyclotron is used for neutron irradiation, radionuclide development, production and material and biomedical research. 50.5MeV and 35MeV proton beam have been extracted with 20-70 .mu.A. A total of beam extraction time are 1095.7 hours. 206.5 hours are used for the developments and 663.8 hours are for radionuclide production and development and 225.4 hours for application researches. The shutdown days are 23days. Fundamental data for failure decrement and efficient beam extraction were composed and maintenance technologies were developed. (author). 8 tabs., 17 figs., 10 refs

  12. Comparison of local International Sensitivity Index calibration and 'Direct INR' methods in correction of locally reported International Normalized Ratios: an international study. On behalf of the European Action of Anticoagulation

    DEFF Research Database (Denmark)

    Poller, L; Keown, M; Ibrahim, S

    2007-01-01

    collaborative study at 77 centers has compared local INR correction using the two alternative methods recommended in the Scientific and Standardization Committee of the International Society on Thrombosis and Haemostasis guidelines: local ISI calibration and 'Direct INR'. METHODS: Success of INR correction...

  13. Princeton Cyclotron QDDD spectrograph system

    International Nuclear Information System (INIS)

    Kouzes, R.T.

    1985-01-01

    A review of experiments involving the Princeton Quadrupole-Dipole-Dipole- Dipole (QDDD) spectrograph is given. The QDDD is a high resolution, large solid angle device which is combined with the azymuthally varying field (AVF) cyclotron. Some reactions involving 3 He beams are discussed

  14. PIXE analysis by baby cyclotron

    International Nuclear Information System (INIS)

    Yoshida, Hyogo; Tanaka, Teruaki; Ito, Takashi; Toda, Yohjiro; Wakasa, Hideichiro

    1988-01-01

    The Japan Steel Works, Ltd. has been supplying a very small sized cyclotron (Baby Cyclotron) to hospitals and research facilities. The cyclotron is designed to produce short-lived radioisotopes for medical use. In the present study, this cyclotron is modified so that it can serve for PIXE analysis. The PIXE (particle induced X-ray emission) technique has the following features: (1) Down to 1 ng of trace material in a sample (mg - μg) can be detected, (2) An analysis run is completed in one to ten minutes, permitting economical analysis for a large number of samples, (3) Several elements can be analyzed simultaneously, with an almost constant sensitivity for a variety of elements ranging from aluminum to heavy metals, (4) Analysis can be performed nondestructively without a chemical process, and (5) The use of microbeam can provide data on the distribution of elements with a resolution of several μm. Software for analysis is developed to allow the modified equipment to perform peak search, background fitting, and identification and determination of peaks. A study is now being conducted to examine the performance of the equipment for PIXE analysis of thin samples. Satisfactory results have been obtained. The analysis time, excluding the background correction, is 5-10 min. (Nogami, K.)

  15. Ion sources for cyclotron applications

    International Nuclear Information System (INIS)

    Leung, K.N.; Bachman, D.A.; McDonald, D.S.; Young, A.T.

    1992-07-01

    The use of a multicusp plasma generator as an ion source has many advantages. The development of both positive and negative ion beams based on the multicusp source geometry is presented. It is shown that these sources can be operated at steady state or cw mode. As a result they are very suitable for cyclotron operations

  16. Ponderomotive force near cyclotron resonance

    Energy Technology Data Exchange (ETDEWEB)

    Kono, Mitsuo; Sanuki, Heiji

    1987-01-01

    The ponderomotive force, which is involved in the excitation of macroscopic behaviors of plasma caused by wave motion, plays an important role in various non-linear wave motion phenomena. In the present study, equations for the pondermotive force for plasma in a uniform magnetic field is derived using a renormalization theory which is based on the Vlasov equation. It is shown that the pondermotive force, which diverges at the cyclotron resonence point according to adiabatic approximation, can be expressed by a non-divergent equation by taking into account the instability of the cyclotron orbit due to high-order scattering caused by a wave. This is related with chaotic particle behaviors near cyclotron resonance, where the pondermotive force is small and the diffusion process prevails. It is assumed here that the amplitude of the high-frequency electric field is not large and that the broadening of cyclotron levels is smaller than the distance between the levels. A global chaos will be created if the amplitude of the electric field becomes greater to allow the broadening to exceed the distance between the levels. (Nogami, K.).

  17. Cyclotron transitions of bound ions

    Science.gov (United States)

    Bezchastnov, Victor G.; Pavlov, George G.

    2017-06-01

    A charged particle in a magnetic field possesses discrete energy levels associated with particle rotation around the field lines. The radiative transitions between these levels are the well-known cyclotron transitions. We show that a bound complex of particles with a nonzero net charge displays analogous transitions between the states of confined motion of the entire complex in the field. The latter bound-ion cyclotron transitions are affected by a coupling between the collective and internal motions of the complex and, as a result, differ from the transitions of a "reference" bare ion with the same mass and charge. We analyze the cyclotron transitions for complex ions by including the coupling within a rigorous quantum approach. Particular attention is paid to comparison of the transition energies and oscillator strengths to those of the bare ion. Selection rules based on integrals of collective motion are derived for the bound-ion cyclotron transitions analytically, and the perturbation and coupled-channel approaches are developed to study the transitions quantitatively. Representative examples are considered and discussed for positive and negative atomic and cluster ions.

  18. Status report on cyclotron operation

    CERN Document Server

    Kovács, P; Ander, I; Lakatos, T; Fenyvesi, A; Ditrói, F; Takács, S; Tarkanyi, F

    2003-01-01

    The operation of the cyclotron in 2002 was concentrated to 9 months; January, July and August were reserved for maintenance and holidays. The overall working time of the accelerator was 4084 hours, the breakdown periods amounted to 15 hours last year. In order to improve the circumstances of the irradiations, several following improvements were done. (R.P.)

  19. A review of the clinical utility of INR to monitor and guide administration of prothrombin complex concentrate to orally anticoagulated patients

    DEFF Research Database (Denmark)

    Sølbeck, Sacha; Ostrowski, Sisse R; Johansson, Pär I

    2012-01-01

    the initiation steps of the haemostatic process. The objective of the present review was to reassess the evidence for using INR as a tool to guide administration of prothrombin complex concentrates (PCC) to OAC patients. A Medline and Cochrane database search was conducted using the following keywords...... value to aim for when reversing OAC was found. In three of the studies it was reported that patients reaching their target INR continued to bleed, whereas three studies reviewed reported good haemostatic response also in patients that did not reach their target INR. The present review found limited...

  20. Impact of INR monitoring, reversal agent use, heparin bridging, and anticoagulant interruption on rebleeding and thromboembolism in acute gastrointestinal bleeding.

    Directory of Open Access Journals (Sweden)

    Naoyoshi Nagata

    Full Text Available Anticoagulant management of acute gastrointestinal bleeding (GIB during the pre-endoscopic period has not been fully addressed in American, European, or Asian guidelines. This study sought to evaluate the risks of rebleeding and thromboembolism in anticoagulated patients with acute GIB.Baseline, endoscopy, and outcome data were reviewed for 314 patients with acute GIB: 157 anticoagulant users and 157 age-, sex-, and important risk-matched non-users. Data were also compared between direct oral anticoagulants (DOACs and warfarin users.Between anticoagulant users and non-users, of whom 70% underwent early endoscopy, no endoscopy-related adverse events or significant differences were found in the rate of endoscopic therapy need, transfusion need, rebleeding, or thromboembolism. Rebleeding was associated with shock, comorbidities, low platelet count and albumin level, and low-dose aspirin use but not HAS-BLED score, any endoscopic results, heparin bridge, or international normalized ratio (INR ≥ 2.5. Risks for thromboembolism were INR ≥ 2.5, difference in onset and pre-endoscopic INR, reversal agent use, and anticoagulant interruption but not CHA2DS2-VASc score, any endoscopic results, or heparin bridge. In patients without reversal agent use, heparin bridge, or anticoagulant interruption, there was only one rebleeding event and no thromboembolic events. Warfarin users had a significantly higher transfusion need than DOACs users.Endoscopy appears to be safe for anticoagulant users with acute GIB compared with non-users. Patient background factors were associated with rebleeding, whereas anticoagulant management factors (e.g. INR correction, reversal agent use, and drug interruption were associated with thromboembolism. Early intervention without reversal agent use, heparin bridge, or anticoagulant interruption may be warranted for acute GIB.

  1. Status of the development of RU-43 fuel at INR Pitesti

    International Nuclear Information System (INIS)

    Horhoianu, G.

    2008-01-01

    More than 50000 fuel bundles containing natural uranium fuel have been irradiated in the CANDU-6 reactors of Cernavoda-Romania NPP, with a very low defect rate, to a core-average discharge burnup of 170-190 Mwh/kgU. Recovered uranium (RU) is a by-product of many light-water reactor (LWR) fuel recycling programs. After fission products and plutonium (Pu) have been removed from spent LWR fuel, RU is left. A fissile content in the RU of 0.9 to 1.1% makes it impossible for reuse in an LWR without re-enrichment, but CANDU reactors have a sufficiently high neutron economy to use RU as fuel. RU from spent LWR fuel can be considered as a lower cost source of enrichment at the optimal enrichment level for CANDU fuel pellets. In Europe the feedstock of RU is approaching thousands tones and would provide sufficient fuel for hundreds CANDU-6 reactors years of operation. The use of RU fuel offers significant benefits to CANDU reactor operators. RU fuels improves fuel cycle economics by increasing the fuel burnup, which enables large cost reductions in fuel consumption and in spent fuel disposal. RU fuel offers enhanced operating margins that can be applied to increase reactor power. These benefits can be realized using existing fuel production technologies and practices, and with almost negligible changes to fuel receipt and handling procedures at the reactor. The application of RU fuel could be an important element in Cernavoda NPP. For this reason the Institute for Nuclear Research (INR), Pitesti has started a research programme aiming to develop a new fuel bundle RU-43 for extended burnup operation. The most relevant calculations performed on this fuel bundle design version are presented. Also, the stages of an experimental program aiming to verify the operating performance are briefly described in this paper. (orig.)

  2. Development of cyclotron solid targetry

    International Nuclear Information System (INIS)

    D'Souza, J.; Deans, T.; Cryer, D.; Price, R.

    2004-01-01

    Full text: Western Australia's first medical cyclotron was recently installed in the Department of Medical Technology and Physics at Sir Charles Gairdner Hospital. The cyclotron is routinely used for 18 F production using a liquid target, and now research is being undertaken into solid target bombardment for production of novel isotopes such as 124 I, 64 Cu and 96 Tc. The IBA Cyclone 18/9 has a maximum proton beam energy of 18MeV and maximum beam current of 80μA. A proton beam is generated by the acceleration of H- ions in the evacuated cyclotron (10 -6 bar) which are then stripped of 2 electrons just prior to exiting a target port. Each port has two strippers which are made of 10μm thick carbon with dimensions 12mmxl3mm. Due to their thinness, the strippers are easily ruptured. The Cyclone 18/9 has 8 target ports. In order to fit a target onto the cyclotron when the cyclotron is already evacuated the target is first evacuated to 10 -3 bar by a roughing pump before an isolation valve at the port is opened. This stops any damage that may occur by the flow of air from the target reservoir to the cyclotron eg to the strippers. The first step in the project to develop solid targetry is to build a beam line in order to measure the beam profile. If successful, this design will be improved in order to have a beam line and target holder that are suitable for use in solid target bombardment. A 40cm beam line with an internal diameter of 3.6cm was built to fit onto the IBA Cyclone 18/9. The beam line, made out of aluminium, incorporates a step 5cm from the end at which a target material can be fitted. A cover fits onto the beam line, behind the target in order to maintain vacuum. The cover is held in place by the vacuum within the beam line. At the end of bombardment, the beam line can be isolated from the vacuum of the target and normal air pressure restored. In doing so the cover plate falls open and the target falls into a lead pot, ready for removal from the cyclotron

  3. The Active Metabolite of Warfarin (3'-Hydroxywarfarin) and Correlation with INR, Warfarin and Drug Weekly Dosage in Patients under Oral Anticoagulant Therapy: A Pharmacogenetics Study.

    Science.gov (United States)

    Gemmati, Donato; Burini, Francesco; Talarico, Anna; Fabbri, Matteo; Bertocco, Cesare; Vigliano, Marco; Moratelli, Stefano; Cuneo, Antonio; Serino, Maria Luisa; Avato, Francesco Maria; Tisato, Veronica; Gaudio, Rosa Maria

    2016-01-01

    Warfarin oral anticoagulant therapy (OAT) requires regular and frequent drug adjustment monitored by INR. Interindividual variability, drug and diet interferences, and genetics (VKORC1 and CYP2C9) make the maintenance/reaching of stable INR a not so easy task. HPLC assessment of warfarin/enantiomers was suggested as a valid monitoring-tool along with INR, but definite results are still lacking. We evaluated possible correlations between INR, warfarin/3'-hydroxywarfarin, and drug weekly dosage aimed at searching novel alternatives to OAT monitoring. VKORC1/CYP2C9 pharmacogenetics investigation was performed to account for the known influence on warfarin homeostasis. 133 OAT patients were recruited and assessed for warfarin/3'-hydroxywarfarin serum levels (HPLC), INR, and VKORC1 and CYP2C9 genotypes. A subgroup of 52 patients were monitored in detail (5 consecutive controls; c0-c4) till the target INR was reached. Correlation analyses were performed in both groups. In the whole OAT group both warfarin and 3'-hydroxywarfarin correlate with INR at comparable degree (r2 = 0.0388 and 0.0362 respectively). Conversely, warfarin weekly dosage better correlates with warfarin than with 3'-hydroxywarfarin (r2 = 0.0975 and r2 = 0.0381 respectively), but considering together warfarin plus 3'-hydroxywarfarin the correlation strongly increased (r2 = 0.1114; ppharmacogenetics studies confirmed that patients carrying the VKORC1 variant-allele required lower warfarin maintenance dosage and that the combination of VKORC1 and CYP2C9 yielded a warfarin responsive index (WRI) inversely related to the number variant alleles. Our results overall suggest that 3'-hydroxywarfarin monitoring could be of great advantage in INR monitoring respect to classical warfarin assessment showing significant contribution also in multivariate analysis. Therefore, additional active metabolites should be recognized and investigated as novel useful indicators.

  4. The reliability of point-of-care prothrombin time testing. A comparison of CoaguChek S and XS INR measurements with hospital laboratory monitoring.

    LENUS (Irish Health Repository)

    Ryan, F

    2010-02-01

    The development of point-of-care (POC) testing devices enables patients to test their own international normalized ratio (INR) at home. However, previous studies have shown that when compared with clinical laboratory values, statistically significant differences may occur between the two methods of INR measurement. The aim of this study was to evaluate the accuracy of the CoaguChek S and XS POC meters relative to clinical laboratory measurements. As part of a randomized, crossover patient self-testing (PST) study at Cork University Hospital, patients were randomized to 6 months PST or 6 months routine care by the anticoagulation management service. During the PST arm of the study, patients measured their INR at home using the CoaguChek S or XS POC meter. External quality control was performed at enrollment, 2 months and 4 months by comparing the POC measured INR with the laboratory determined value. One hundred and fifty-one patients provided 673 paired samples. Good correlation was shown between the two methods of determination (r = 0.91), however, statistically significant differences did occur. A Bland-Altman plot illustrated good agreement of INR values between 2.0 and 3.5 INR units but there was increasing disagreement as the INR rose above 3.5. Eighty-seven per cent of all dual measurements were within the recommended 0.5 INR units of each other. This study adds to the growing evidence that POC testing is a reliable and safe alternative to hospital laboratory monitoring but highlights the importance of external quality control when these devices are used for monitoring oral anticoagulation.

  5. Neutron radiography with the cyclotron

    International Nuclear Information System (INIS)

    Tazawa, Shuichi; Asada, Yorihisa; Yano, Munehiko; Nakanii, Takehiko.

    1985-01-01

    Neutron radiography is well recognized as a powerful tool in nondestructive testing, but not widely used yet owing to lack of high intense thermal neutron source convenient for practical use. This article presents a new neutron radiograph facility, utilizing a sub-compact cyclotron as neutron source and is equipped with vertical and horizontal irradiation ports. The article describes a series of experiments, we conducted using beams of a variable energy cyclotron at Tohoku University to investigate the characteristics of thermal neutron obtained from 9 Be(p, n) reaction and thermalized by elastic scattering process. The article also describes a computer simulation of neutron moderator to analyze conditions getting maximal thermal neutron flux. Further, some of practical neutron radiograph examinations of aero-space components and museum art objects of classic bronze mirror and an attempt realizing real time imaging technique, are introduced in the article. (author)

  6. The development of cyclotron radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Seung Dae; Chun, K. W.; Suh, Y. S.; Lee, J. D.; Ahn, S. H. and others

    1999-03-01

    The purpose of this project is to developthe radiopharmaceuticals and automatic synthetic unit for labelled compounds, and to establish mass production system of radiopharmaceuticals. These will contribute to the early diagnosis of the disease hard to cure. The contents of this project are as follows, the development of the radiopharmaceutical for imaging of cancer, the development of automatic synthesizer for the synthesis of radio-pharmaceuticals, the development of hormone derivatives labelled with {sup 12}'3I, the development of the radiopharmaceuticals for therapy of cancer labelled with cyclotron produced radionuclides, the development of radiopharmaceuticals for therapy of cancer labelled with cyclotron produced radionuclides, the development of radiopharmaceuticals for imaging of myocardial metabolism.

  7. Cyclotron radiation from hot plasmas

    International Nuclear Information System (INIS)

    Pohl, F.; Henning, J.; Duechs, D.

    1975-11-01

    In calculating the energy transport and losses due to cyclotron radiation there are two major requirements: the absorption coefficient has to be known and the proper geometry of the plasma has to be taken into account. In this report Trubnikov's integral formulae for the absorption coefficient have been evaluated numerically and compared with the approximative formulas of previous authors. Deviations by a factor of 2 - 10 in various frequency regimes are not unusual. With these coefficients the rate of change of the energy density due to cyclotron radiation in a plasma as well as the radiation density at a plasma surface are computed for plasma slab and plasma cylinder. Sometimes considerable differences to the results of previons papers can found. Many simple formulae interpolating the numerical results are given in the text, and the FORTRAN computer programs have been reproduced in the appendices. (orig.) [de

  8. Cyclotron production of Cu-61

    Czech Academy of Sciences Publication Activity Database

    Lebeda, Ondřej; Ráliš, Jan; Seifert, Daniel

    2013-01-01

    Roč. 40, 2 Supplement (2013), S323-S323 ISSN 1619-7070. [Annual Congress of the European Association of Nuclear Medicine (EANM). 19.10.2013-23.10.2013, Lyon] R&D Projects: GA TA ČR TA02010797 Institutional support: RVO:61389005 Keywords : cyclotron U-120M * PET * Cu-61 Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders

  9. Status report on the cyclotron

    International Nuclear Information System (INIS)

    Kormany, Z.

    2002-01-01

    Complete text of publication follows. The operation of the cyclotron in 2001 was again concentrated to the usual 9 months; January, July and August were reserved for maintenance and holidays. The overall working time of the accelerator was 4300 hours, the breakdown periods amounted to 66 hours last year. The cyclotron was available for users during 3751 hours, the effectively used beam-on-target time is summarized in Table 1. The total time required for machine setup and beam tuning or spent waiting for the start of an irradiation was 272 hours. The control of the adjustable collimators applied in the beam transport system of the cyclotron was renewed during the winter maintenance period. They have been connected to the programmable logic controllers (PLC) and their new control code frees the operators from the long and slow manual setting process. The successful renewal of the control of this and other subsystems (cyclotron and beam transport power supplies) made lots of adjusting and measuring elements on the original control desk needless. To provide more space for the control PCs and remove all unnecessary devices, the unused part of the control desk has been dismantled. The short beam line used mainly for radiation hardness studies was equipped with a new oil-diffusion vacuum system during the summer maintenance. Its components are also connected to the PLC and the same automatic control has been provided like for the other vacuum stands of- the beam transport system. Another short beam line - basically a mirror image of the first one - has also been installed and successfully tested by trial irradiations. (R.P.)

  10. Commercial compact cyclotrons in the 90's

    International Nuclear Information System (INIS)

    Milton, B.F.

    1995-09-01

    Cyclotrons continue to be efficient accelerators for radio-isotope production. In recent years, developments in the accelerator technology have greatly increased the practical beam current in these machines while also improving the overall system reliability. These developments combined with the development of new isotopes for medicine and industry, and a retiring of older machines indicate a strong future for commercial cyclotrons. In this paper we will survey recent developments in the areas of cyclotron technology, as they relate to the new generation of commercial cyclotrons. Design criteria for the different types of commercial cyclotrons will be presented, with reference to those demands that differ from those in a research oriented cyclotron project. We will also discuss the possibility of systems designed for higher energies and capable of extracted beam currents of up to 2.0 mA. (author)

  11. Commercial compact cyclotrons in the 90's

    International Nuclear Information System (INIS)

    Milton, B.F.

    1995-09-01

    Cyclotrons continue to be efficient accelerators for radio-isotope production. In recent years, developments in the accelerator technology have greatly increased the practical beam current in these machines while also improving the overall system reliability. These developments combined with the development of new isotopes for medicine and industry, and a retiring of older machines indicate a strong future for commercial cyclotrons. In this paper the authors will survey recent developments in the areas of cyclotron technology, as they relate to the new generation of commercial cyclotrons. Design criteria for the different types of commercial cyclotrons will be presented, with reference to those demands that differ from those in a research oriented cyclotron project. The authors also discuss the possibility of systems designed for higher energies and capable of extracted beam currents of up to 2.0 mA

  12. Method and apparatus for ion cyclotron spectrometry

    Science.gov (United States)

    Dahl, David A [Idaho Falls, ID; Scott, Jill R [Idaho Falls, ID; McJunkin, Timothy R [Idaho Falls, ID

    2010-08-17

    An ion cyclotron spectrometer may include a vacuum chamber that extends at least along a z-axis and means for producing a magnetic field within the vacuum chamber so that a magnetic field vector is generally parallel to the z-axis. The ion cyclotron spectrometer may also include means for producing a trapping electric field within the vacuum chamber that includes at least a first section that induces a first magnetron effect that increases a cyclotron frequency of an ion and at least a second section that induces a second magnetron effect that decreases the cyclotron frequency of an ion. The cyclotron frequency changes induced by the first and second magnetron effects substantially cancel one another so that an ion traversing the at least first and second sections will experience no net change in cyclotron frequency.

  13. Future cyclotron systems : an industrial perspective

    International Nuclear Information System (INIS)

    Stevenson, N.R.; Dickie, W.J.

    1995-09-01

    The use of commercial cyclotron systems for the production of radioisotopes continues to grow on a world-wide scale. Improvements in technology have significantly increased the production capabilities of modem cyclotron-based isotope production facilities. In particular, the change to negative ion acceleration and new high power systems have resulted in dramatic improvements in reliability, increases in capacity, and decreases in personnel radiation dose. As more and more older machines are retired decisions regarding their replacement are made based on several factors including the market's potential and the cyclotron system's abilities. Taking the case of the recently upgraded TR30 cyclotron at TRIUMF/Nordion, we investigate the requirements industrial/medical users are likely to impose on future commercial cyclotron systems and the impact this will have on cyclotron technology by the end of the century. (author)

  14. Future cyclotron systems: An industrial perspective

    International Nuclear Information System (INIS)

    Stevenson, N.R.; Dickie, W.J.

    1995-09-01

    The use of commercial cyclotron systems for the production of radioisotopes continues to grow on a world-wide scale. Improvements in technology have significantly increased the production capabilities of modern cyclotron-based isotope production facilities. In particular, the change to negative ion acceleration and new high power systems have resulted in dramatic improvements in reliability, increases in capacity, and decreases in personnel radiation dose. As more and more older machines are retired, decisions regarding their replacement are made based on several factors including the market's potential and the cyclotron system's abilities. Taking the case of the recently upgraded TR30 cyclotron at TRIUMF/Nordion, the authors investigate the requirements industrial/medical users are likely to impose on future commercial cyclotron systems and the impact this will have on cyclotron technology by the end of the century

  15. A new cyclotron for biomedical research

    International Nuclear Information System (INIS)

    Wolber, G.

    1988-01-01

    This paper presents the rationale for replacing the old AEG Compact Cyclotron (built in 1969/71) of the Institute for Radiology and Pathophysiology at the German Cancer Research Center by a 30 MeV H - /15 MeV D - cyclotron. A status report is followed by the scientific and technical reasoning as well as budgetary and organizational considerations. In the appendix we tried to explain the function of a cyclotron in a simple and comprehensive manner. (orig.) [de

  16. On-site emergency intervention plan for nuclear accident situation at INR-Pitesti TRIGA reactor

    International Nuclear Information System (INIS)

    Oprea, I.; Margenu, S.; Preda, M.

    2001-01-01

    evaluate alternative countermeasure strategies in the various stage of an accident. In this way, we have developed at INC Pitesti a computer code namely DOZIM which is presented. The structure of the emergency intervention plan, as objectives, general features and procedures is given. Each year there is organized at INR Pitesti an emergency intervention exercise for a nuclear accident situation at the TRIGA reactor. The main objective of such an exercise is to test the response capability in a nuclear accident situation for all the institutions and organizations from all levels as well as to test the implementation of specific procedures

  17. Advances in superconducting cyclotrons at MSU

    International Nuclear Information System (INIS)

    Blosser, H.; Antaya, T.; Au, R.

    1987-01-01

    Intensive work on superconducting cyclotrons began at MSU in late 1973 (a brief earlier study had occurred in the early 1960's) and continues vigorously at present. One large cyclotron, the ''K500'', has been operating for a number of years, a second, the ''K800'', is nearing completion, the first operating tests of its magnet having occurred at the time of the previous conference, and a third, the ''medical cyclotron'', is now also nearing completion with first operation of its magnet expected just after the present conference. These cyclotrons like other superconducting cyclotrons are all dramatically smaller than comparable room temperature machines; overall weight is typically about 1/20th of that of room temperature cyclotrons of the same energy. This large reduction in the quantities of materials is partially offset by added complexity, but finally, a net overall cost savings of 50 to 70 % typically results; as a consequence the superconducting cyclotron is widely viewed as the cyclotron of the future. The thirteen years of experience at MSU involving three of these cyclotrons, together with much important work at other laboratories, gives a rather clear view of the advantages and disadvantages of various design approaches including by now a rather significant period of long term evaluation. This paper reviews highlights of this program. (author)

  18. The INR program in 2000-2005 period for developing the national technical support of the nuclear power

    International Nuclear Information System (INIS)

    Gheorghiu, C.

    2001-01-01

    The INR - Pitesti is largely implied in implementing the tasks of high complexity stipulated by the Emergency Directive of the Romanian Government No. 144/30.09.1999 meant to ensure the national technical support for the nuclear power field as well as the development of presupposed international cooperation. The Strategic Program of the Autonomous Authority for Nuclear Activities (RAAN) stipulates the main activities to be carried-out in the period 2000-2005 and beyond, in the frame of 18 specific programs. These programs approaches high priority world wide issues targeting major objectives like efficient operation of NPPs ensuring the design service life, creating conditions for extension of operation duration increasing the safety standard of personnel, of population as well as reducing the impact of nuclear power upon the environmental. Also, the program approaches functionally the problem of safety management of the radioactive waste resulting from nuclear facility operation. Achieving these major objective as well as of those specific laid down in the Strategic Program requires continual supply with material and human resources, refurbishment of material background of INR in its research and development activities as well as a consistent integration of the INR staff of researchers within the international scientific community. Implementing the annual programs included in the Strategic Program will ensure also fulfilment of the international arrangements of our country as well as the realization of the agreements concluded by the Ministry of Industry and Resources and RAAN with analogous authorities from abroad (AECL - Canada, DOE - USA, etc.). This document has the following content: 1. Legislative support and the mission of the program; 2. Program's strategic objectives; 3. General technical objectives of the programs. 4. Financing; 5. Providing and training human resources; 6. Investments for research and development; 7. International cooperation; 8

  19. Gene polymorphisms and the risk of warfarin-induced bleeding complications at therapeutic international normalized ratio (INR)

    Energy Technology Data Exchange (ETDEWEB)

    Pourgholi, Leyla [Department of Pathology and Laboratory Medicine, Tehran Heart Center, Tehran University of Medical Sciences, P.O. Box 1411713138, Tehran (Iran, Islamic Republic of); Department of Pharmacology & Toxicology, School of Pharmacy, Kerman University of Medical Sciences, P.O. Box 7616911319, Kerman (Iran, Islamic Republic of); Goodarzynejad, Hamidreza [Department of Cardiac Research, Tehran Heart Center, Tehran University of Medical Sciences, P.O. Box 1411713138, Tehran (Iran, Islamic Republic of); Mandegary, Ali [Department of Pharmacology & Toxicology, School of Pharmacy, Kerman University of Medical Sciences, P.O. Box 7616911319, Kerman (Iran, Islamic Republic of); Gastroenterology and Hepatology Research Center, Afzalipour' s Hospital, Imam Highway, P.O. Box 7616913911, Kerman (Iran, Islamic Republic of); Ziaee, Shayan [Department of Pathology and Laboratory Medicine, Tehran Heart Center, Tehran University of Medical Sciences, P.O. Box 1411713138, Tehran (Iran, Islamic Republic of); Talasaz, Azita Hajhosseini [Department of Cardiac Research, Tehran Heart Center, Tehran University of Medical Sciences, P.O. Box 1411713138, Tehran (Iran, Islamic Republic of); Department of Clinical Pharmacy, School of Pharmacy, Tehran University of Medical Sciences (Iran, Islamic Republic of); Jalali, Arash [Department of Cardiac Research, Tehran Heart Center, Tehran University of Medical Sciences, P.O. Box 1411713138, Tehran (Iran, Islamic Republic of); Boroumand, Mohammadali, E-mail: maboroumand@yahoo.com [Department of Pathology and Laboratory Medicine, Tehran Heart Center, Tehran University of Medical Sciences, P.O. Box 1411713138, Tehran (Iran, Islamic Republic of)

    2016-10-15

    Background: Bleeding episodes commonly occur in patients on warfarin treatment even in those within therapeutic range of international normalized ratio (INR). The objective of this study was to investigate the effects of the 8 examined polymorphisms on the risk of bleeding complications in a sample of Iranian patients. Methods: A total of 552 warfarin treated patients who maintained on a target INR level of 2.0–3.5 for at least three consecutive intervals were enrolled from those attended our anticoagulation clinics. Ninety-two bleeding events were observed in 87 patients. The presences of the examined polymorphisms were analyzed using polymerase chain reaction-based restriction fragment length polymorphism (PCR-RFLP). Results: Patients with the T allele in NQO1*2 (CT or TT genotypes) had a higher risk of bleeding than patients with the CC genotype (adjusted OR: 2.25, 95% CI: 1.37 to 3.70, P = 0.001). Those who were carriers of CYP2C9 one-variant haplotypes (*1/*2 or *1/*3) were also found to be associated with the higher risk of bleeding events. Compared to reference group (*1/*1), the odds of bleeding increased for carriers of one variant allele (*1/*2 or *1/*3) (adjusted OR: 1.75, 95% CI: 1.03 to 2.97, P = 0.039). Variant VKORC1, Factor VII, and EPHX1 genotypes were not significantly associated with the risk of bleeding events. Conclusion: The SNP C609T within NQO1 and haplotypes of CYP2C9 (1*2 or 1*3) are independently associated to bleeding complications of warfarin at normal INR. Further studies are required to confirm such associations in diverse racial and ethnic populations. - Highlights: • NQO1 C609T variant is associated with warfarin induced bleeding at therapeutic INR. • Haplotypes of CYP2C9 (1*2 or 1*3) are also associated with bleeding events. • VKORC1, Factor VII, and EPHX1 genotypes were not associated with bleeding risk.

  20. Management of radioactive waste at INR-technical support for processing of radioactive waste from nuclear facilities

    International Nuclear Information System (INIS)

    Bujoreanu, D.; Popescu, I.V.; Bujoreanu, L.

    2009-01-01

    The Institute for nuclear research (INR) subsidiary of the Romanian authority for nuclear activities has its own radwaste treatment plant (STDR). STDR is supposed to treat and condition radioactive waste from the nuclear fuel facility, the TRIGA reactor, post irradiation examination laboratories and other research laboratories of NRI. The main steps of waste processing are: pretreatment (collection, characterization, segregation, decontamination)., treatment (waste volume reduction, radionuclide removal, compositional change), conditioning (immobilization and containerization), interim storage of the packages in compliance with safety requirements for the protection of human health and environmental protection, transport of the packages containing radioactive waste, disposal.

  1. Gene polymorphisms and the risk of warfarin-induced bleeding complications at therapeutic international normalized ratio (INR)

    International Nuclear Information System (INIS)

    Pourgholi, Leyla; Goodarzynejad, Hamidreza; Mandegary, Ali; Ziaee, Shayan; Talasaz, Azita Hajhosseini; Jalali, Arash; Boroumand, Mohammadali

    2016-01-01

    Background: Bleeding episodes commonly occur in patients on warfarin treatment even in those within therapeutic range of international normalized ratio (INR). The objective of this study was to investigate the effects of the 8 examined polymorphisms on the risk of bleeding complications in a sample of Iranian patients. Methods: A total of 552 warfarin treated patients who maintained on a target INR level of 2.0–3.5 for at least three consecutive intervals were enrolled from those attended our anticoagulation clinics. Ninety-two bleeding events were observed in 87 patients. The presences of the examined polymorphisms were analyzed using polymerase chain reaction-based restriction fragment length polymorphism (PCR-RFLP). Results: Patients with the T allele in NQO1*2 (CT or TT genotypes) had a higher risk of bleeding than patients with the CC genotype (adjusted OR: 2.25, 95% CI: 1.37 to 3.70, P = 0.001). Those who were carriers of CYP2C9 one-variant haplotypes (*1/*2 or *1/*3) were also found to be associated with the higher risk of bleeding events. Compared to reference group (*1/*1), the odds of bleeding increased for carriers of one variant allele (*1/*2 or *1/*3) (adjusted OR: 1.75, 95% CI: 1.03 to 2.97, P = 0.039). Variant VKORC1, Factor VII, and EPHX1 genotypes were not significantly associated with the risk of bleeding events. Conclusion: The SNP C609T within NQO1 and haplotypes of CYP2C9 (1*2 or 1*3) are independently associated to bleeding complications of warfarin at normal INR. Further studies are required to confirm such associations in diverse racial and ethnic populations. - Highlights: • NQO1 C609T variant is associated with warfarin induced bleeding at therapeutic INR. • Haplotypes of CYP2C9 (1*2 or 1*3) are also associated with bleeding events. • VKORC1, Factor VII, and EPHX1 genotypes were not associated with bleeding risk.

  2. Summary on electron cyclotron theory

    International Nuclear Information System (INIS)

    Westerhof, E.

    2003-01-01

    The papers presented within the Theory Sessions of the conference clearly reflect the general trends of the research field. The growing use of Electron Bernstein Waves (EBW) for plasma heating and current drive in overdense plasmas goes hand in hand with an increased theoretical understanding of EBW excitation. While the expanding number of devices with powerful ECRH systems allowing ever more detailed experiments is reflected in the increased detail of modelling and consequent understanding of the experimental results. Apart from these general trends, some more fundamental contributions to the field of electron cyclotron wave propagation are highlighted. (author)

  3. Studies of electron cyclotron emission on text

    International Nuclear Information System (INIS)

    Gandy, R.F.

    1990-07-01

    The Auburn University electron cyclotron emission (ECE) system has made many significant contributions to the TEXT experimental program during the past five years. Contributions include electron temperature information used in the following areas of study: electron cyclotron heating (ECH), pellet injection, and impurity/energy transport. Details of the role which the Auburn ECE system has played will now be discussed

  4. Cyclotrons for the production of radioactive beams

    International Nuclear Information System (INIS)

    Clark, D.J.

    1990-01-01

    This paper describes the characteristics and design choices for modern cyclotrons. Cyclotrons can be used in 3 areas in the radioactive beam field: the production of high energy heavy ion beams for use in fragmentation, the spallation of targets with high energy protons, and the acceleration of radioactive beams from low energy to the MeV/u range. 16 refs., 6 figs

  5. Isochronous cyclotron for thermonuclear reactors driving

    International Nuclear Information System (INIS)

    Alenitskij, Yu.G.

    1998-01-01

    The main requirements to an accelerator as a part of an electronuclear power plant are considered. The range of the parameters of the accelerated proton and deuteron beams, for which the isochronous cyclotron is the most profitable, is proposed. An opportunity of using the cyclotron to drive the research reactors of various types is considered

  6. Trends in cyclotrons for radionuclide production

    International Nuclear Information System (INIS)

    Vera Ruiz, H.; Lambrecht, R.M.

    1999-01-01

    The IAEA recently concluded a worldwide survey of the cyclotrons used for radionuclide production. Most of the institutions responded to the questionnaire. The responses identified technical, utilisation and administrative information for 206 cyclotrons. Compiled data includes the characteristics, performance and popularity of each of the different commercial cyclotrons. Over 20 cyclotrons are scheduled for installation in 1998. The expansion in the number of cyclotron installations during the last decade was driven by the advent of advances in medical imaging instrumentation (namely, positron emission tomography (PET), and more recently by 511 KeV emission tomography); introduction of user friendly compact medical cyclotrons; and recent governmental decisions that permit reimbursement for cyclotron radiopharmaceutical studies by the government or insurance companies. The priorities for the production of clinical, commercial and research radionuclides were identified. The emphasis is on radionuclides used for medical diagnosis with SPET (e.g. 123 I, 201 Tl) and PET (e.g. 11 C, 13 N, 15 O, 18 F) radiopharmaceuticals, and for individualized patient radiation treatment planning (e.g. 64 Cu, 86 Y, 124 I) with PET. There is an emerging trend to advance the cyclotron as an alternative method to nuclear reactors for the production of neutron-rich radionuclides (e.g. 64 Cu, 103 Pd, 186 Re) needed for therapeutic applications. (authors)

  7. Wave fronts of electromagnetic cyclotron harmonic waves

    International Nuclear Information System (INIS)

    Ohnuma, T.; Watanabe, T.

    1982-01-01

    In an inhomogeneous high-density magnetized plasma, the spatial properties of the wave fronts and ray trajectories of electromagnetic ordinary and extraordinary cyclotron harmonic waves are investigated. Those waves which are radiated from a local source are found to have wave fronts which are almost parallel to the magnetic field. Also, the reflective properties of the electromagnetic cyclotron harmonic waves are confirmed

  8. Recent development and progress of IBA cyclotrons

    Energy Technology Data Exchange (ETDEWEB)

    Kleeven, W., E-mail: Willem.Kleeven@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Abs, M., E-mail: Michel.Abs@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Delvaux, J.L., E-mail: Jean-Luc.Delvaux@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Forton, E., E-mail: Eric.Forton@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Jongen, Y., E-mail: Yves.Jongen@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Medeiros Romao, L., E-mail: Luis.MedeirosRomao@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Nactergal, B., E-mail: Benoit.Nactergal@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Nuttens, V., E-mail: Vincent.Nuttens@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Servais, T., E-mail: Thomas.Servais@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Vanderlinden, T., E-mail: Thierry.Vanderlinden@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium); Zaremba, S., E-mail: Simon.Zaremba@iba-group.com [Ion Beam Applications s.a. Chemin du Cyclotron 3, Louvain-la-Neuve (Belgium)

    2011-12-15

    Several cyclotron development projects were recently realized by Ion Beam Applications S.A. (IBA). This contribution presents three of them: (i) the intensity enhancement of the Cyclone 30 cyclotron, a machine mainly used for the production of SPECT isotopes. This project is related with the increased demand for {sup 201}Tl because of the shortage of Mo/Tc generators from nuclear reactors, (ii) development of a new versatile multiple-particle K = 30 isotope-production cyclotron (the Cyclone 30XP) being able to accelerate H{sup -}, D{sup -} and also {alpha}-particles. The {alpha}-beam of this cyclotron will allow the production of new therapeutic isotopes (e.g. {sup 211}At) and (iii) commissioning of the Cyclone 70 cyclotron installed for Arronax in France. This machine is similar to the C30XP but provides higher energy (K = 70) and allows research on new types of medical isotopes.

  9. Developing the smallest possible medical cyclotron

    CERN Multimedia

    Katarina Anthony

    2011-01-01

    Imagine a portable medical cyclotron operated in a conventional radioactive facility at a hospital. Imagine a nurse or technician switching it on and producing isotopes at the patient’s bedside. Sounds like science fiction? Think again.   CERN has teamed up with Spain’s national scientific research centre (CIEMAT) to develop an avant-garde cyclotron to be used for Positron Emission Tomography (PET). “We plan to make a cyclotron that doesn't need an insulated building or ‘vault’: a cyclotron small enough to fit inside a hospital lift,” explains Jose Manuel Perez, who is leading the CIEMAT/CERN collaboration. “It will be the smallest possible medical cyclotron for single patient dose production and will dramatically reduce costs for hospitals.” While PET technology has transformed imaging techniques, many of its medical benefits have remained confined to highly specialised hospitals. “Studies have foun...

  10. Computer design of a compact cyclotron

    International Nuclear Information System (INIS)

    Bing Wang; Huanfeng Hao; Qinggao Yao; Jinquan Zhang; Mingtao Song; Vorozhtsov, S.B.; Smirnov, V.L.; Hongwei Zhao

    2011-01-01

    Here we present results of the computer design of the structural elements of a compact cyclotron by the example of HITFiL cyclotron selected as the driving accelerator that is under construction at the Institute of Modern Physics (Lanzhou, China). In the article a complex approach to modeling of the compact cyclotron, including calculation of electromagnetic fields of the structural elements and beam dynamics calculations, is described. The existing design data on the axial injection, magnetic, acceleration and extraction systems of the cyclotron are used as a starting point in the simulation. Some of the upgrades of the cyclotron structural elements were proposed, which led to substantial improvement of the beam quality and transmission

  11. The Active Metabolite of Warfarin (3'-Hydroxywarfarin) and Correlation with INR, Warfarin and Drug Weekly Dosage in Patients under Oral Anticoagulant Therapy: A Pharmacogenetics Study

    Science.gov (United States)

    Talarico, Anna; Fabbri, Matteo; Bertocco, Cesare; Vigliano, Marco; Moratelli, Stefano; Cuneo, Antonio; Serino, Maria Luisa; Avato, Francesco Maria

    2016-01-01

    Objectives Warfarin oral anticoagulant therapy (OAT) requires regular and frequent drug adjustment monitored by INR. Interindividual variability, drug and diet interferences, and genetics (VKORC1 and CYP2C9) make the maintenance/reaching of stable INR a not so easy task. HPLC assessment of warfarin/enantiomers was suggested as a valid monitoring-tool along with INR, but definite results are still lacking. We evaluated possible correlations between INR, warfarin/3’-hydroxywarfarin, and drug weekly dosage aimed at searching novel alternatives to OAT monitoring. VKORC1/CYP2C9 pharmacogenetics investigation was performed to account for the known influence on warfarin homeostasis. Methods 133 OAT patients were recruited and assessed for warfarin/3’-hydroxywarfarin serum levels (HPLC), INR, and VKORC1 and CYP2C9 genotypes. A subgroup of 52 patients were monitored in detail (5 consecutive controls; c0-c4) till the target INR was reached. Correlation analyses were performed in both groups Results In the whole OAT group both warfarin and 3’-hydroxywarfarin correlate with INR at comparable degree (r2 = 0.0388 and 0.0362 respectively). Conversely, warfarin weekly dosage better correlates with warfarin than with 3’-hydroxywarfarin (r2 = 0.0975 and r2 = 0.0381 respectively), but considering together warfarin plus 3’-hydroxywarfarin the correlation strongly increased (r2 = 0.1114; pwarfarin (r2 = 0.2157 and r2 = 0.0549; p = 0.0005 and p = 0.0944 respectively) seeming less affected by drug adjustments in the subgroup of 52 patients who started OAT. The multivariate analyses aimed at estimating the true contribution of 3’-hydroxywarfarin on INR value ascribed it the unique significant value (p = 0.0021) in spite of warfarin who lost association. The pharmacogenetics studies confirmed that patients carrying the VKORC1 variant-allele required lower warfarin maintenance dosage and that the combination of VKORC1 and CYP2C9 yielded a warfarin responsive index (WRI

  12. Cyclotron-Resonance-Maser Arrays

    International Nuclear Information System (INIS)

    Kesar, A.; Lei, L.; Dikhtyar, V.; Korol, M.; Jerby, E.

    1999-01-01

    The cyclotron-resonance-maser (CRM) array [1] is a radiation source which consists of CRM elements coupled together under a common magnetic field. Each CRM-element employs a low-energy electron-beam which performs a cyclotron interaction with the local electromagnetic wave. These waves can be coupled together among the CRM elements, hence the interaction is coherently synchronized in the entire array. The implementation of the CRM-array approach may alleviate several technological difficulties which impede the development of single-beam gyro-devices. Furthermore, it proposes new features, such as the phased-array antenna incorporated in the CRM-array itself. The CRM-array studies may lead to the development of compact, high-power radiation sources operating at low-voltages. This paper introduces new conceptual schemes of CRM-arrays, and presents the progress in related theoretical and experimental studies in our laboratory. These include a multi-mode analysis of a CRM-array, and a first operation of this device with five carbon-fiber cathodes

  13. Production of radiopharmaceuticals by cyclotrons

    International Nuclear Information System (INIS)

    Schmitz, F.; Van Naemen, J.; Monclus, M.; Van Gansbeke, B.; Kadiata, M.; Ekelmans, D.; Moray, M.; Penninckx, R.; Goldman, S.

    2004-01-01

    Companies specialized in the development and installation of accelerator-based systems dedicated to the medical applications brought on the market cyclotrons well fitted to the requests of the industrial community or universities and so covering every segment of the market. These machines are fully automatic, and need reduced maintenance; they are highly specialized for defined tasks. They can produce high beam intensity and realize dual beam irradiation. Also the prices are reducing considerably. The targets and the automatic system follow the same trend. Unfortunately, the flexibility of these devices for new area of research and development has been dramatically reduced. The growing number of PET cameras has increased the popularity of PET tracers used for nuclear imaging. Consequently, there is a growing demand for these radiopharmaceuticals compounds labeled with short-lived radioisotopes for clinical applications. From a research and development tool in the eighties, PET has now grown up to a clinical tool. Moreover, depending of the social welfare, reimbursement of some PET examinations is granted, which accelerates the trend for an extended use of PET tracers. Regulatory affairs try to establish and standardize the control on these radiopharmaceutical compounds produced in a growing number of local radio pharmacies owning a baby cyclotron. On the other hand, the attention of equipment suppliers was brought in the setting up of a total quality control follow up. These efforts were successively achieved by getting for instance the ISO 9001 certificate

  14. Medical cyclotron basic concepts and its applications

    International Nuclear Information System (INIS)

    Kumar, Rajeev; Sonkawade, R.G.

    2012-01-01

    More than 3000 nuclides are known, of which approximately 2700 are radioactive, and rest are stable. The majority of radionuclides are artificially produced in the reactor and cyclotron. In a cyclotron, Charge particle such as proton, Deuteron, á (Alpha) particle, 3 He particles and so forth are accelerated in circular paths within the Dees under vacuum by means of an electromagnetic field. These accelerated particles can possess few KeV to several BeV of kinetic energy depending on the design of the cyclotron. At our setup we have an 11 MeV dual beam multi target cyclotron which is capable producing 11 C, 13 N, 15 O, 18 F and 2 F radioisotopes and all have been successfully produced and tested in our lab. Earlier cyclotrons were the best source of high-energy beams for nuclear physics experiments; several cyclotrons are still in use for this type of research. Cyclotrons can be used to treat cancer. Ion beams from cyclotrons can be used, as in proton therapy. The positron emitting isotopes are suitable for PET imaging. As discussed we are producing mainly Carbon-11, Nitrogen-13, Oxygen-15, and Fluorine-18: These are positron emitters used in PET for studying brain physiology and pathology, in particular for localizing epileptic focus, and in dementia, psychiatry and neuropharmacology studies. So these are having significant role in diagnosis of Oncological, Neurological and Cardiological disorder. More than ninety percent we are producing 18 F in FDG. 18 F in FDG (Flouro-Deoxy-glucose) has become very important in detection of cancers and the monitoring of progress in their treatment, using PET. Medical cyclotron is complex equipment requiring delicate handling by highly trained personnel. The aim of this article is to highlight few finer aspects of Medical cyclotron operation, including precautions for safety and smooth functioning of this sophisticated equipment. (author)

  15. The role of research programs and commercial contracts for increase of economic competitiveness and development at INR Pitesti

    International Nuclear Information System (INIS)

    Petra, Nicoleta Mihaela; Ionila, Maria; Datcu, Mirela; Balan, Iosif Bogdan; Cretu, Ileana

    2008-01-01

    In the period in which globalization is increasing, one of the strategic objectives of the institute is to focus on those activities which help developing of services, products and technologies, applicable in nuclear industry, environment protection and medicine. One way to sustain INR activity is the technological transfer which ensures availability of research results by carrying out of R and D contracts in priority areas and of contracts with economical agents for the supply of services, products, technologies, such as: - Materials irradiation for medicine, industry and research; - Neutron Activation Analysis (NAA) and prompt gamma spectrometry for Cernavoda NPP - Unit 1; - Control and testing: non-destructive examination, functional tests of samples and equipment from Cernavoda NPP - Unit 1; - Characterization, conditioning and treatment of radioactive wastes for NPP- Cernavoda, Unit 1, Nuclear Fuel Plant (FCN) - Pitesti; - Measurement of isotopes concentration in environmental samples; -Corrosion experiments in static autoclaves and experiments regarding microbial corrosion for NPP Cernavoda Unit 1 and FCN Pitesti; - Nuclear consultancy for Cernavoda NPP - Unit 1 and Unit 2; - Stainless steel casks for radwaste; - Containers for heavy water; - Training and practice for students at the Universities of Pitesti, Bucuresti, Brasov. The paper presents the main areas where the results obtained in R and D programs can be applied, their implementation can be done, and the status of contracts and their importance for INR Pitesti and Romanian society development, as well. (authors)

  16. [A sudden rise in INR due to combination of Tribulus terrestris, Avena sativa, and Panax ginseng (Clavis Panax)].

    Science.gov (United States)

    Turfan, Murat; Tasal, Abdurrahman; Ergun, Fatih; Ergelen, Mehmet

    2012-04-01

    Warfarin sodium is an antithrombin agent used in patients with prosthetic valve and atrial fibrillation. However, there are many factors that can change the effectiveness of the drug. Today, herbal mixtures promoted through targeted print and visual media can lead to sudden activity changes in patients using warfarin. In this case report we will present two cases with a sudden rise in INR due to using combination of Tribulus terrestris, Avena sativa and Panax ginseng (Panax Clavis). Two patients who used warfarin due to a history of aortic valve replacement (case 1) and atrial fibrillation (case 2) were admitted to the hospital due very high levels of INR detected during routine follow-up. Both patients had used an herbal medicine called ''Panax'' during the last month. The patients gave no indication regarding a change in diet or the use of another agent that might interact with warfarin. In cases where active bleeding could not be determinated, we terminated the use of the drug and re-evaluated dosage of warfarin before finally discharging the patient.

  17. The international normalized ratio (INR as seen in a population of patients with atrial fibrillation and cerebral infarction undergoing long-term treatment with vitamin K antagonists

    Directory of Open Access Journals (Sweden)

    Szczepańska-Szerej Anna

    2015-12-01

    Full Text Available It is estimated that nearly 20% of all cerebral infarctions in the total population are the result of a complication of atrial fibrillation (AF. While oral anticoagulation with vitamin K antagonists (AVKs substantially reduces this risk, this requires regular monitoring of the international normalized ratio (INR in order to achieve therapeutic levels (2,0-3,0. The aim of this study was to evaluate a group at high risk of cerebral infarction, among patients with AF undergoing long-term treatment with VKAs, taking into account the significance of therapeutic INR values. The analysed group consisted of 90 acute ischaemic stroke patients with paroxysmal or chronic “non-valvular” AF, receiving treatment with VKAs. As a result of the study, therapeutic INR values (≥ 2 were seen in thirty-five of these individuals (38,8%, while 55 (61,2% showed non-therapeutic INR values. Moreover, there were no differences in demographics, vascular risk factors, biochemical and morphological blood parameters, mean CHA2DS2-VASc score and TOAST classification between either of the two groups. Furthermore, no additional factor that would increase their risk of cerebral infarction during the adequate treatment with VKAs was found. However, patients with non-therapeutic INR values had a statistically significantly higher frequency of concomitant moderate pathology of the bicuspid valve, p<0.05. Hence, a lack of proper control of INR can proved to be particularly dangerous for this subgroup of patients. Hence, this is a group with an elevated risk of cerebral infarction and therefore requires special oversight of VKA treatment or NOA treatment.

  18. Electron cyclotron resonance plasma photos

    Energy Technology Data Exchange (ETDEWEB)

    Racz, R.; Palinkas, J. [Institute of Nuclear Research (ATOMKI), H-4026 Debrecen, Bem ter 18/c (Hungary); University of Debrecen, H-4010 Debrecen, Egyetem ter 1 (Hungary); Biri, S. [Institute of Nuclear Research (ATOMKI), H-4026 Debrecen, Bem ter 18/c (Hungary)

    2010-02-15

    In order to observe and study systematically the plasma of electron cyclotron resonance (ECR) ion sources (ECRIS) we made a high number of high-resolution visible light plasma photos and movies in the ATOMKI ECRIS Laboratory. This required building the ECR ion source into an open ECR plasma device, temporarily. An 8MP digital camera was used to record photos of plasmas made from Ne, Ar, and Kr gases and from their mixtures. We studied and recorded the effect of ion source setting parameters (gas pressure, gas composition, magnetic field, and microwave power) to the shape, color, and structure of the plasma. The analysis of the photo series gave us many qualitative and numerous valuable physical information on the nature of ECR plasmas.

  19. Electron cyclotron resonance plasma photos

    International Nuclear Information System (INIS)

    Racz, R.; Palinkas, J.; Biri, S.

    2010-01-01

    In order to observe and study systematically the plasma of electron cyclotron resonance (ECR) ion sources (ECRIS) we made a high number of high-resolution visible light plasma photos and movies in the ATOMKI ECRIS Laboratory. This required building the ECR ion source into an open ECR plasma device, temporarily. An 8MP digital camera was used to record photos of plasmas made from Ne, Ar, and Kr gases and from their mixtures. We studied and recorded the effect of ion source setting parameters (gas pressure, gas composition, magnetic field, and microwave power) to the shape, color, and structure of the plasma. The analysis of the photo series gave us many qualitative and numerous valuable physical information on the nature of ECR plasmas.

  20. Channeling experiments at IPNE Cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Constantin, F; Dumitru, M; Ivan, A [Cyclotron Laboratory, Institute of Atomic Physics, Institute of Physics and Nuclear Engineering, R-76900 Bucharest, P.O.Box MG-6, (Romania)

    1992-01-01

    Channeling experiments have been performed at the I.P.N.E Cyclotron using a 3 MeV alpha beam. A slide system cut the beam up to 5 minutes spatial resolution with a maximum 60 nA beam current on the target. The two-axis goniometer, fully computer-controlled, moves the target, a silicon wafer, with 2.5 minute resolution, while an alpha particle sensitive solid state detector, monitors the backscattered particle fluence. In the first stage, channeling appears to be a simple, fast and reliable method for precise monocrystal orientation. A reduction of the host yield by a factor of two allowed impurities and defects to be studied. (Author).

  1. Cyclotron resonance in bilayer graphene.

    Science.gov (United States)

    Henriksen, E A; Jiang, Z; Tung, L-C; Schwartz, M E; Takita, M; Wang, Y-J; Kim, P; Stormer, H L

    2008-02-29

    We present the first measurements of cyclotron resonance of electrons and holes in bilayer graphene. In magnetic fields up to B=18 T, we observe four distinct intraband transitions in both the conduction and valence bands. The transition energies are roughly linear in B between the lowest Landau levels, whereas they follow square root[B] for the higher transitions. This highly unusual behavior represents a change from a parabolic to a linear energy dispersion. The density of states derived from our data generally agrees with the existing lowest order tight binding calculation for bilayer graphene. However, in comparing data to theory, a single set of fitting parameters fails to describe the experimental results.

  2. Frequency of different disorders requiring warfarin therapy and its outcome in terms of dosage and inr value in pakistani population

    International Nuclear Information System (INIS)

    Qayyum, A.; Najmi, M.H.

    2014-01-01

    To determine the frequency of different disorders requiring warfarin therapy and to see the target INR and warfarin dose requirement in Pakistani population. Study Design:Descriptive study. Setting and Duration of Study: The study was carried out at Armed Forces Institut e of Cardiology (AFIC) Rawalpindi, Military Hospital Rawalpindi and National Institute of Cardiovascular Diseases (NICVD), Karachi, Pakistan from October 2010 to March 2012. Patients and Methods: Stable patients taking warfarin therapy were recruited after detailed medical history, physical examination and laboratory tests. The demographic and clinical data of individuals were entered in a pre-structured proforma. Patients suffering from hepatic and renal disease, any co-morbid disease or taking any concurrent medication or diet which would have affected warfarin therapy, were excluded. Data was analyzed using PSS version 20.0. Results: A total of 607 stable patients fulfilling the eligibility criteria, participated in the study. There were 297 (48.9%) male and 310 (51.1%) female patients. The mean age was 37.93 +- 12.23 years (range 18-65 years). The most common indication for warfarin therapy was valvular heart diseases (93.4%) followed by atrial fibrillation (2.3%) whereas other indications for warfarin use are less commonly seen in our study population. Patients had mean international normalized ratio (INR) value of 2.3 +9- 0.8 (range 1.5-3.5). Mean daily dose of warfarin calculated in 607 patients was 5.62 and 1.98 mg with the range of 0.36-15 g whereas mean weekly dose was 39.36 +- 13.8 mg with the range of 2.5-105 mg. Conclusion: In Pakistani population the most common indications for warfarin use are valvular heart diseases followed by atrial fibrillation. The mean INR values were within recommended range of 2-3. The mean daily dose observed in long-term therapy is comparable to the empirical dose of 5 mg routinely started in clinical practice. (author)

  3. All-magnetic extraction for cyclotron beam reacceleration

    Science.gov (United States)

    Hudson, E.D.; Mallory, M.L.

    1975-07-22

    An isochronous cyclotron can be modified to provide an initial electron stripping stage, a complete acceleration of the stripped ions through the cyclotron to a first energy state, means for returning the ions to an intermediate cyclotron orbit through a second stripping stage, further acceleration of the now higher energy stripped ions through the cyclotron to their final energy, and final extraction of the ions from the cyclotron. (auth)

  4. Method and apparatuses for ion cyclotron spectrometry

    Science.gov (United States)

    Dahl, David A [Idaho Falls, ID; Scott, Jill R [Idaho Falls, ID; McJunkin, Timothy R [Idaho Falls, ID

    2012-03-06

    An ion cyclotron spectrometer may include a vacuum chamber that extends at least along a z-axis and means for producing a magnetic field within the vacuum chamber so that a magnetic field vector is generally parallel to the z-axis. The ion cyclotron spectrometer may also include means for producing a trapping electric field within the vacuum chamber. The trapping electric field may comprise a field potential that, when taken in cross-section along the z-axis, includes at least one section that is concave down and at least one section that is concave up so that ions traversing the field potential experience a net magnetron effect on a cyclotron frequency of the ions that is substantially equal to zero. Other apparatuses and a method for performing ion cyclotron spectrometry are also disclosed herein.

  5. NORTICA - a new code for cyclotron analysis

    International Nuclear Information System (INIS)

    Gorelov, D.; Johnson, D.; Marti, F.

    2001-01-01

    The new package NORTICA (Numerical ORbit Tracking In Cyclotrons with Analysis) of computer codes for beam dynamics simulations is under development at NSCL. The package was started as a replacement for the code MONSTER developed in the laboratory in the past. The new codes are capable of beam dynamics simulations in both CCF (Coupled Cyclotron Facility) accelerators, the K500 and K1200 superconducting cyclotrons. The general purpose of this package is assisting in setting and tuning the cyclotrons taking into account the main field and extraction channel imperfections. The computer platform for the package is Alpha Station with UNIX operating system and X-Windows graphic interface. A multiple programming language approach was used in order to combine the reliability of the numerical algorithms developed over the long period of time in the laboratory and the friendliness of modern style user interface. This paper describes the capability and features of the codes in the present state

  6. Development of a Medical Cyclotron Production Facility

    Science.gov (United States)

    Allen, Danny R.

    2003-08-01

    Development of a Cyclotron manufacturing facility begins with a business plan. Geographics, the size and activity of the medical community, the growth potential of the modality being served, and other business connections are all considered. This business used the customer base established by NuTech, Inc., an independent centralized nuclear pharmacy founded by Danny Allen. With two pharmacies in operation in Tyler and College Station and a customer base of 47 hospitals and clinics the existing delivery system and pharmacist staff is used for the cyclotron facility. We then added cyclotron products to contracts with these customers to guarantee a supply. We partnered with a company in the process of developing PET imaging centers. We then built an independent imaging center attached to the cyclotron facility to allow for the use of short-lived isotopes.

  7. Development of a Medical Cyclotron Production Facility

    International Nuclear Information System (INIS)

    Allen, Danny R.

    2003-01-01

    Development of a Cyclotron manufacturing facility begins with a business plan. Geographics, the size and activity of the medical community, the growth potential of the modality being served, and other business connections are all considered. This business used the customer base established by NuTech, Inc., an independent centralized nuclear pharmacy founded by Danny Allen. With two pharmacies in operation in Tyler and College Station and a customer base of 47 hospitals and clinics the existing delivery system and pharmacist staff is used for the cyclotron facility. We then added cyclotron products to contracts with these customers to guarantee a supply. We partnered with a company in the process of developing PET imaging centers. We then built an independent imaging center attached to the cyclotron facility to allow for the use of short-lived isotopes

  8. 10 GHz ECRIS for Warsaw Cyclotron

    CERN Document Server

    Sudlitz, K

    1999-01-01

    Cusp type, 10 GHz ECRIS has been built and tested earlier. For obtaining intensive beams, more relevant for cyclotron, cusp geometry has been replaced by hexapole. Discharge chamber (stainless steel, 50 mm diameter, 250 mm long) is an extension of a coaxial line, feeding RF (9,6 GHz, up to 200 W) to the plasma. The NdFeB hexapole (0,52 T on the surface) has been used. The axial magnetic field is created by water cooled coils. The axial injection line dedicated to K160 isochronous heavy ion cyclotron has been constructed. The line consists of Glaser lenses, double focusing magnet, solenoid and mirror type inflector. The system provides sufficient transmission of the beam from ECR ion source to the firsts orbits of the cyclotron for m/q ranging from 7 to 2. After successful initial tests which were done in July 1997 the ECRIS serves as an external source for Warsaw Cyclotron.

  9. Application of superconductivity in cyclotron construction

    International Nuclear Information System (INIS)

    Blosser, H.G.

    1982-01-01

    This paper reviews major concepts and design features of the new class of cyclotrons which use superconducting coils to provide main magnet excitation. The discussion begins with a brief historical review tracing the evolution of these ''superconducting'' cyclotrons and the impact of this application of superconductivity in pushing back traditional cyclotron construction limits. This is followed by a review of the principal phenomena which come into play to set new limits on the operating regime, and the nature of these limits, some of which arise from orbit properties and some of which result from construction intricacies in the coil and in the rf system. Conclusions anticipate a future widely encompassing role in the application of superconductivity to cyclotron

  10. Progress report: Variable Energy Cyclotron Centre, Calcutta

    International Nuclear Information System (INIS)

    1999-01-01

    This volume of the progress report brings out the scientific and technical activities of Variable Energy Cyclotron Centre, Calcutta during the year 1999. This includes brief review of the various R and D activities of the Centre and outside users of the cyclotron from the universities and other research institutes. The operational activities of the cyclotron with ECR ion sources, accelerator oriented research activities, activities on detector, target and electronics are reported. The activities of the Computer and Informatics group are described. The status report of the ongoing projects is also provided. The main activities of the superconducting cyclotron project, radioactive ion beam project, heavy ion experimental facility, advanced computational facility, recovery and analysis of helium from hot springs and material science research are described

  11. Electron cyclotron emission imaging in tokamak plasmas

    NARCIS (Netherlands)

    Munsat, T.; Domier, C.W.; Kong, X. Y.; Liang, T. R.; N C Luhmann Jr.,; Tobias, B. J.; Lee, W.; Park, H. K.; Yun, G.; Classen, I.G.J.; Donne, A. J. H.

    2010-01-01

    We discuss the recent history and latest developments of the electron cyclotron emission imaging diagnostic technique, wherein electron temperature is measured in magnetically confined plasmas with two-dimensional spatial resolution. The key enabling technologies for this technique are the

  12. Cyclotron/PET project in Uruguay

    International Nuclear Information System (INIS)

    Engler, H.

    2006-01-01

    The Positron Computed Tomography (PET) is a tri dimensional image technique which shows biochemical information. PET is used in neurology and cardiology diseases. The National Center Cyclotron PET has been found to research, development and health science applications.

  13. Cyclotron method for heavy ion acceleration

    International Nuclear Information System (INIS)

    Gikal, B.N.; Gul'bekyan, G.G.; Kutner, V.B.; Oganesyan, R.Ts.

    1984-01-01

    Studies on heavy ion beams in a wide range of masses (up to uranium) and energies disclose essential potential opportunities for solution of both fundamental scientific and significant economical problems. A cyclotron method for heavy ion acceleration is considered. Development of low and medium energy heavy ion accelerators is revealed. The design of a complex comprising two isochronous cyclotrons which is planned to be constrdcted 1n the JINR is described. The cyclotron complex includes the U-400 and the U-400 M cyclotrons and it is intended for acceleration of both 35-20 MeV/nucleon superheavy ions such as Xe-U and 120 MeV/nucleon light ions. Certain systems of the accelerators are described. Prospects of the U-400 and the U-400 M development are displayed

  14. Warfarin dose and INR related to genotypes of CYP2C9 and VKORC1 in patients with myocardial infarction

    Directory of Open Access Journals (Sweden)

    Seljeflot Ingebjørg

    2008-06-01

    Full Text Available Abstract Background Warfarin treatment has a narrow therapeutic range, requiring meticulous monitoring and dosage titration. Individual dosage requirement has recently partly been explained by genetic variation of the warfarin metabolizing enzyme CYP2C9 and the Vitamin K-activating enzyme VKORC1. In the WARIS-II study, comparing three different antithrombotic regimens after myocardial infarction, warfarin treatment reduced thrombotic events, but was associated with more frequent bleeding than use of acetylsalisylic acid (ASA alone. Aims The primary aim of the present study was to investigate the relation between genotypes of CYP2C9 and VKORC1 and warfarin maintenance dose in myocardial infarction. The secondary aim was to relate the genotypes to international normalized ratio (INR. Methods Genotyping was performed in 212 myocardial infarction patients from the WARIS-II study by robotic isolation of DNA from EDTA whole blood (MagNa Pure LC before PCR amplification (LightCycler and melting point analysis. Results The 420 C>T substitution of CYP2C9*2, the 1075 A>C substitution of CYP2C9*3 and the 1173 C>T substitution of VKORC1 had minor allele frequencies of, 11.3%, 5.7% and 36.6% respectively. Warfarin weekly dose varied between 17 mg and 74 mg among the patients. INR did not vary between genotypes. Warfarin dosage requirement was significantly associated with CYP2C9 and VKORC1 genotypes, treatment group and age. The VKORC1 genotype contributed 24.5% to the interindividual variation in warfarin dosage, whereas the combined CYP2C9 genotypes were only responsible for 7.2% of the dose variation. Conclusion CYP2C9 and VKORC1 genotype frequencies in myocardial infarction patients appear similar to other patient groups and have similar impact on warfarin maintenance dose.

  15. Progress report on the Milan superconducting cyclotron

    International Nuclear Information System (INIS)

    Acerbi, E.; Alessandria, F.; Baccaglioni, G.; Bellomo, G.; Birattari, C.; Bosotti, A.; Broggi, F.; Cortesi, G.; DeMartinis, C.; Fabrici, E.; Ferrari, A.; Giove, D.; Giussani, A.; Giussani, W.; Michelato, P.; Pagani, C.; Rivoltella, G.; Rossi, L.; Serafini, L.; Sussetto, A.; Torri, V.; Varisco, G.; Cuttone, G.; Raia, G.; Kai, L.

    1988-01-01

    This paper reports on the construction of the K800 superconducting cyclotron at the University of Milan underway since February 1981. The delay in the construction of the new building and a defect of the weldings of the helium vessel have caused a shift in the project schedule of about two years. Currently, the cyclotron magnet and the cryogenic plant have been completed and installed. First operation of the magnet and magnetic field mapping are to begin shortly

  16. Building 211 cyclotron characterization survey report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-30

    The Building 211 Cyclotron Characterization Survey includes an assessment of the radioactive and chemical inventory of materials stored within the facility; an evaluation of the relative distribution of accelerator-produced activation products within various cyclotron components and adjacent structures; measurement of the radiation fields throughout the facility; measurement and assessment of internal and external radioactive surface contamination on various equipment, facility structures, and air-handling systems; and an assessment of lead (Pb) paint and asbestos hazards within the facility.

  17. NIRS-Chiba isochronous cyclotron 1975

    International Nuclear Information System (INIS)

    Ogawa, H.; Kumamoto, Y.; Yamada, T.; Hiramoto, T.

    1976-02-01

    The cyclotron facility installed according to the recommendation of the Atomic Energy Committee of Japan is used for neutron therapy and production of short-lived radioisotopes. Construction on the facility was started in the autumn of 1972, and completed in March 1974. Described are the following: beam transport and the experimental hall, machine research and improvement, machine time sharing and the particles and energies, characteristics of the cyclotron, and facility personnel. (auth.)

  18. Initial operation of the cyclotron CYTRACK

    International Nuclear Information System (INIS)

    Denisov, Yu.N.; Dolya, S.N.; Kalinichenko, V.V.; Karamysheva, G.A.; Kostromin, S.A.; Fedorenko, S.B.

    2005-01-01

    The industrial cyclotron CYTRACK is dedicated to produce the track membranes. It is the basic instrument for the industry of membrane products to be consumed in medicine, biotechnology, pharmacology, microelectronics and many other industries. Cyclotron CYTRACK started working in August 2002. Argon ions were accelerated to the project energy - 2.4 MeV/nucleon, the extracted beam intensity was about 200 nA, the extraction efficiency totaled ∼50%

  19. Cyclotron beam dynamic simulations in MATLAB

    International Nuclear Information System (INIS)

    Karamysheva, G.A.; Karamyshev, O.V.; Lepkina, O.E.

    2008-01-01

    MATLAB is useful for beam dynamic simulations in cyclotrons. Programming in an easy-to-use environment permits creation of models in a short space of time. Advanced graphical tools of MATLAB give good visualization features to created models. The beam dynamic modeling results with an example of two different cyclotron designs are presented. Programming with MATLAB opens wide possibilities of the development of the complex program, able to perform complete block of calculations for the design of the accelerators

  20. TRial of an Educational intervention on patients' knowledge of Atrial fibrillation and anticoagulant therapy, INR control, and outcome of Treatment with warfarin (TREAT

    Directory of Open Access Journals (Sweden)

    Pattison Helen M

    2010-05-01

    Full Text Available Abstract Background Atrial fibrillation (AF patients with a high risk of stroke are recommended anticoagulation with warfarin. However, the benefit of warfarin is dependent upon time spent within the target therapeutic range (TTR of their international normalised ratio (INR (2.0 to 3.0. AF patients possess limited knowledge of their disease and warfarin treatment and this can impact on INR control. Education can improve patients' understanding of warfarin therapy and factors which affect INR control. Methods/Design Randomised controlled trial of an intensive educational intervention will consist of group sessions (between 2-8 patients containing standardised information about the risks and benefits associated with OAC therapy, lifestyle interactions and the importance of monitoring and control of their International Normalised Ratio (INR. Information will be presented within an 'expert-patient' focussed DVD, revised educational booklet and patient worksheets. 200 warfarin-naïve patients who are eligible for warfarin will be randomised to either the intervention or usual care groups. All patients must have ECG-documented AF and be eligible for warfarin (according to the NICE AF guidelines. Exclusion criteria include: aged Discussion More data is needed on the clinical benefit of educational intervention with AF patients receiving warfarin. Trial registration ISRCTN93952605

  1. Ion-cyclotron-resonance- and Fourier-transform-ion-cyclotron-resonance spectroscopy: technology and application

    International Nuclear Information System (INIS)

    Luederwald, I.

    1977-01-01

    Instrumentation and technology of Ion-Cyclotron-Resonance and Fourier-Transform-Ion-Cyclotron-Resonance Spectroscopy are described. The method can be applied to studies of ion/molecule reactions in gas phase, to obtain thermodynamic data as gas phase acidity or basicity, proton and electron affinity, and to establish reaction mechanisms and ion structures. (orig.) [de

  2. A national medical cyclotron facility: report to the Minister of Health by the Medical Cyclotron Committee

    International Nuclear Information System (INIS)

    1985-01-01

    Research and training in nuclear medicine in Australia are both limited by the lack of a medical cyclotron facility. The Committee recommends the establishment of a national medical cyclotron to provide a supply of short-lived radioisotopes for research in relevant fields of medicine, and for diagnostic use in nuclear medicine

  3. 57 Co produced in cyclotron

    International Nuclear Information System (INIS)

    Landini, Liliane; Osso Junior, Joao Alberto

    2000-01-01

    The Cyclotron CV-28 of IPEN-CNEN/SP is a particle accelerator, used mainly in the radioisotope production, applied in 'in vivo' diagnosis in nuclear medicine. Some of them are employed in the calibration of Diagnosis equipment, such as gamma and X-rays detectors. Co-57 is an example of this application. A natural nickel foil was used as target and irradiated with proton beams of 24 MeV energy. The radioactivity analysis of the irradiated target was performed by Gamma Spectroscopy with a HPGe detector. A 259,74MBq (7,02 mCi) Co-57 source was prepared, 67 days after the last bombardment, with impurity levels of 1.13% for Co-56 and 1.29% for Co-58. The thick target yields for Co-57 and for the main radionuclidic impurities were measured, after the chemical separation of the irradiated target, extrapolated to the last EOB: 1.076 MBq (29.09 mCi)/mA.h, 0.012 MBq (0.33 mCi)/mA.h and 0.014 MBq (0.37 mCi)/mA.h, for Co-57, Co-56 and Co-58, respectively. (author)

  4. Electron cyclotron heating of plasmas

    International Nuclear Information System (INIS)

    Guest, Gareth

    2009-01-01

    As nuclear fusion becomes an increasingly important potential energy source in these times of global oil and energy crises, the development of technologies that can lead to the realization of this virtually inexhaustible source of energy takes on ever greater urgency. Over the past decade electron cyclotron heating has undergone a significant maturation and has emerged as an essential component of the major approaches to achieving controlled nuclear fusion. The gyrotron, first developed in the Soviet Union, has made it possible to employ ECH in large tokamak and stellarator fusion devices by providing megawatts of microwave power at frequencies above 100 GHz. A contemporary VGT-8110 gyrotron, for example, shown here with Kevin Felch and Pat Cahalan of Communications and Power Industries, is capable of delivering 10 second pulses of 1 MW of power at 110 GHz. The present monograph addresses the ECH physics critical to the international fusion reactor experiment, ITER, but also presents the fundamentals of ECH that are essential to its successful implementation in applications that range from active experiments in planetary magnetospheres to commercial plasma sources for the manufacture of computer chips. The book seeks to convey the physics of ECH in an orderly and coherent fashion to a professional audience by presenting the basic theoretical foundations and then using the theory to interpret a number of established experimental results. Exercises are included to aid the reader in making the theory more concrete. (orig.)

  5. Cyclotron tubes - a theoretical study

    Energy Technology Data Exchange (ETDEWEB)

    Mourier, G

    1980-12-01

    The introduction presents a general discussion of electron cyclotron masers (ECM): resonance, relativistic effects, elementary quantum aspects, the classical relativistic bunching and the optimum value of the electric field. The practical structure - in particular that of the gyrotron - is specified only insofar as it is useful for understanding the following chapters. The main parameters are discussed. Section 2 develops a nonlinear adiabatic or orbital theory of electron motion which alleviates calculations considerably while keeping numerical errors low enough for many practical cases. Its results are compared to a rigorous integration in one case. Other cases show the importance of the electric field profile inside the resonant cavity. Section 3 is devoted to space charge phenomena, and, for the most part, to a linear theory with space charge. In its limited range of validity (low-energy electrons), the theory indicates a strong impact of space charge for low a.c. fields and exhibits a pure beam instability. Section 4 is devoted to circuit equations with emphasis on the special features of cavities consisting of a long waveguide near cutoff. The conclusion indicates some trends of gyrotron development and corresponding theoretical problems.

  6. Neutron radiography by using JSW baby cyclotron

    International Nuclear Information System (INIS)

    Toda, Yojiro

    1995-01-01

    At present, JSW baby cyclotrons are mostly used for the production of the radioisotopes for medical use. The attempt to use this baby cyclotron for neutron radiography began already in 1981. The feasibility of the neutron radiography for the explosives in metallic cases which are used for H1 rockets was investigated. In 1983, it was shown that the neutron radiography by using the baby cyclotron in Muroran Works, Japan Steel Works, Ltd. was able to be carried out as a routine work. Since then, the nondestructive inspection by neutron radiography has been performed for rocket pyrotechnic articles, and contributed to heighten their reliability. Further, the radiography by using fast neutrons was developed and put to practical use for recent large H2 rockets. The JSW baby cyclotron BC 168 which has been used for neutron radiography can accelerate 16 MeV protons or 8 MeV deuterons up to 50 μA. The principle of thermal neutron radiography is the generation of fast neutrons by irradiating a Be target with the proton beam accelerated by a baby cyclotron, the moderation of the fast neutrons, the formation of the thermal neutron flux of uniform distribution with a collimator, the thermal neutron flux hitting the Gd plate in a film cassette through an object, and the exposure of an X-ray film to electrons from the Gd plate. Fast neutron radiography apparatus, and commercial neutron radiography are described. (K.I.)

  7. 83-inch cyclotron research program. Final report

    International Nuclear Information System (INIS)

    Parkinson, W.C.

    1983-07-01

    In June of 1960 the US Atomic Energy Commission authorized the construction of a modern variable energy cyclotron facility at The University of Michigan to be used for research in nuclear spectroscopy. The Legislature of the State of Michigan made available funds for construction of a building to house the 83-inch cyclotron and auxiliary equipment as well as the University's remodeled 42-inch cyclotron. The research program centered around the 83-inch cyclotron was funded by the AEC and its successors, the Energy Research and Development Administration (ERDA) and the Department of Energy (DOE), from September 1964 through March 1977. The program represented a continuation of the research effort using the 42-inch cyclotron facility which had been supported continuously by the AEC since February 1950. This final report to DOE briefly describes the research facility, the research program, and highlights the principal accomplishments of the effort. It begins with a historical note to place this effort within the context of nuclear physics research in the Department of Physics of the University of Michigan

  8. Manufacturing on the radiopharmaceuticals produced by cyclotron

    International Nuclear Information System (INIS)

    Ueda, Nobuo

    1994-01-01

    Radiopharmaceutical (RP) produced by cyclotrons are widely used for the in vivo diagnosis of various diseases such as cancer, cerebral vascular disorders and cardiac diseases. The nuclides used as RPs and their nuclear reactions, and the quantity of RPs supplied in Japan in the last five years are shown. These RPs are delivered to about 1,100 hospitals in Japan. Thallium-201 and iodine-123 showed very high growth rate. Recently, two new I-123 RPs, BMIPP and MIBG which are heart-imaging agents, have been supplied. It suggests that the quantity of I-123 will increase much more in future. The image diagnostic method using RPs is called in vivo nuclear medicine, and has become the indispensable means for medical institutions together with X-ray CT, nuclear magnetic resonance imaging and ultrasonic diagnosis. The RPs for in vivo diagnosis generally used at present are classified into those labeled with the RIs produced with cyclotrons and those labeled with Tc-99m formed by the decay of Mo-99. The quantity being used is overwhelmingly more in the latter, but the former shows the tendency of growth. The commercial production of cyclotron RIs for medical use, the chemical forms and the diagnostic purposes of the RPs using cyclotron RIs, and the state of use of the cyclotron-produced RPs are reported. (K.I.)

  9. Low energy cyclotron for radiocarbon dating

    International Nuclear Information System (INIS)

    Welch, J.J.

    1984-12-01

    The measurement of naturally occurring radioisotopes whose half lives are less than a few hundred million years but more than a few years provides information about the temporal behavior of geologic and climatic processes, the temporal history of meteoritic bodies as well as the production mechanisms of these radioisotopes. A new extremely sensitive technique for measuring these radioisotopes at tandem Van de Graaff and cyclotron facilities has been very successful though the high cost and limited availability have been discouraging. We have built and tested a low energy cyclotron for radiocarbon dating similar in size to a conventional mass spectrometer. These tests clearly show that with the addition of a conventional ion source, the low energy cyclotron can perform the extremely high sensitivity 14 C measurements that are now done at accelerator facilities. We found that no significant background is present when the cyclotron is tuned to accelerate 14 C negative ions and the transmission efficiency is adequate to perform radiocarbon dating on milligram samples of carbon. The internal ion source used did not produce sufficient current to detect 14 C directly at modern concentrations. We show how a conventional carbon negative ion source, located outside the cyclotron magnet, would produce sufficient beam and provide for quick sampling to make radiocarbon dating milligram samples with a modest laboratory instrument feasible

  10. Recycling and recommissioning a used biomedical cyclotron

    International Nuclear Information System (INIS)

    Carroll, L.R.; Ramsey, F.; Armbruster, J.; Montenero, M.

    2001-01-01

    Biomedical Cyclotrons have a very long life, but there eventually comes a time when any piece of equipment has to be retired from service. From time to time, we have the opportunity to help find new homes for used cyclotrons which, with relatively modest overhaul and refurbishment, can have many additional years of productive service, and thus represent a very valuable asset. The reasons for retiring a cyclotron vary, of course, but in our experience it is often due to an institution's changing priorities or changing needs, rather than the due to any fundamental age-related deficiency in the cyclotron itself. In this paper we will report on the relocation and successful restoration of a used TCC CP-42 cyclotron, which was moved from M.D. Anderson Hospital in Houston to Denton, Texas in early 1998, where it is presently being used for R and D and commercial production of biomedical isotopes. Ownership of the machine has been transferred to the University of North Texas; facility, manpower, and operational resources are provided by International Isotopes, Inc

  11. Superconducting cyclotron magnet coil short

    International Nuclear Information System (INIS)

    Mallory, M.L.; Blosser, H.G.; Clark, D.J.; Launer, H.; Lawton, D.; Miller, P.; Resmini, F.

    1982-01-01

    In February 1981, a short circuit appeared in the superconducting coil of the K500 cyclotron. The short is resistive in character and therefore has no effect on steady state operation of the magnet. The resistance of the short varies, sometimes being below threshold of detection as a heat load on the cooling system and sometimes being significant. The resistance under certain conditions shows approximately cyclic phenomena with time constants in the range of seconds and other approximately cyclic phenomena which correlate with gross operating parameters of the magnet (shifting current from one coil to another at high field and lowering and raising the liquid helium level). A number of diagnostic studies of the short have been made, using 1) an array of flux sensing loops to sense the magnetic effect of the short, 2) voltage comparisons between upper and lower sections of the coil, 3) comparisons of forces in the nine member coil support system and 4) the effect of the short on the thermal charactersitics of the coil. Insulation failure or a metal chip shorting out turns have been explored in some detail but a convincing determination of the exact cause of the short may never be available, (even the extreme step of unwinding the coil having a significant probability that an imperfection with the observed characteristics would pass unnoticed). Analysis of the characteristics of the short indicated that the most serious consequence would be failure of the coils mechanical support system in the event that the magnet was quickly discharged, as in a dump or quench. To deal with this hazard, the support system has been modified by installing solid supports which prevent the coil from moving by an amount sufficient to damage the support system. We have also reexamined the data and calculations used in the original coil design and have made some additional measurements of the properties of the materials (yield strength, friction coefficient, Young's modulus) used in the

  12. Radiation shielding and health physics instrumentation for PET medical cyclotrons

    International Nuclear Information System (INIS)

    Mukherjee, B.

    2002-01-01

    Full text: Modern Medical Cyclotrons produce a variety of short-lived positron emitting PET radioisotopes, and as a result are the source of intense neutron and gamma radiations. Since such cyclotrons are housed within hospitals or medical clinics, there is significant potential for un-intentional exposure to staff or patients in proximity to cyclotron facilities. Consequently, the radiological hazards associated with Cyclotrons provide the impetus for an effective radiological shielding and continuous monitoring of various radiation levels in the cyclotron environment. Management of radiological hazards is of paramount importance for the safe operation of a Medical Cyclotron facility. This work summarised the methods of shielding calculations for a compact hospital based Medical Cyclotron currently operating in Canada, USA and Australia. The design principle and operational history of a real-time health physics monitoring system (Watchdog) operating at a large multi-energy Medical Cyclotron is also highlighted

  13. Statistical fluctuations in cooperative cyclotron radiation

    Science.gov (United States)

    Anishchenko, S. V.; Baryshevsky, V. G.

    2018-01-01

    Shot noise is the cause of statistical fluctuations in cooperative cyclotron radiation generated by an ensemble of electrons oscillating in magnetic field. Autophasing time - the time required for the cooperative cyclotron radiation power to peak - is the critical parameter characterizing the dynamics of electron-oscillators interacting via the radiation field. It is shown that premodulation of charged particles leads to a considerable narrowing of the autophasing time distribution function for which the analytic expression is obtained. When the number of particles Ne exceeds a certain value that depends on the degree to which the particles have been premodulated, the relative root-mean-square deviation (RMSD) of the autophasing time δT changes from a logarithmic dependence on Ne (δT ∼ 1 / lnNe) to square-root (δT ∼ 1 /√{Ne }). A slight energy spread (∼4%) results in a twofold drop of the maximum attainable power of cooperative cyclotron radiation.

  14. Decommissioning analyzis of a university cyclotron

    International Nuclear Information System (INIS)

    Eggermont, G.X.; Buls, N.; Hermanne, A.

    1996-01-01

    In the widespread use of some medical nuclear facilities, such as cyclotrons for isotope production, Life cycle analyzis, including decommissioning, was not taken into account. The structural materials of an accelerator and the concrete shielding of the bunker are activated by neutrons. This could yield a considerable volume of nuclear waste and needs radiation protection concern for occupational workers and the environment during some decennia. At the university of Brussels (WB) a prospective radiation protection and waste analyzis is being made for the later decommissioning of their cyclotron. Only few similar studies have been published. In Belgium future nuclear dismantling operations will be submitted to a radiation protection authorization procedure. Meanwhile the nuclear waste authorities insist on dismantling planning, including financial provisioning. An optimization exercise was made at the VUB-cyclotron, taking into account international trends to clearance levels for low level nuclear waste. Conceptual prevention opportunities e.g. selective material choice could be identified for future accelerator constructions. (author)

  15. Scientific instruments, scientific progress and the cyclotron

    International Nuclear Information System (INIS)

    Baird, David; Faust, Thomas

    1990-01-01

    Philosophers speak of science in terms of theory and experiment, yet when they speak of the progress of scientific knowledge they speak in terms of theory alone. In this article it is claimed that scientific knowledge consists of, among other things, scientific instruments and instrumental techniques and not simply of some kind of justified beliefs. It is argued that one aspect of scientific progress can be characterized relatively straightforwardly - the accumulation of new scientific instruments. The development of the cyclotron is taken to illustrate this point. Eight different activities which promoted the successful completion of the cyclotron are recognised. The importance is in the machine rather than the experiments which could be run on it and the focus is on how the cyclotron came into being, not how it was subsequently used. The completed instrument is seen as a useful unit of scientific progress in its own right. (UK)

  16. Radiation exposure to workers at cyclotron facilities

    International Nuclear Information System (INIS)

    Ribeiro, M.S.; Sanches, M.P.; Sanchez, A.S.; Rodrigues, D.L.

    2001-01-01

    Radiopharmaceuticals quickly furnish the information doctors need to establish a precise diagnosis of the patient's condition, and therefore to prescribe the most effective therapy. In cancerology, F18-FDG, the most widely used PET imaging tracer, excels in the early detection of cancer tumors, even very tiny ones, which it locates and clearly distinguishes from healthy surrounding tissues. IPEN-CNEN/SP has two cyclotron accelerators used mainly for radioisotope production to be utilized in nuclear medicine for diagnosis and therapy. The first is a CV-28 cyclotron, variable energy that came into operation in 1982, which was used to produce F18-FDG and Iodine 123 up to 1998. The second, a Cyclone 30 cyclotron, 30 MeV, commenced operation in 1998 for certification purpose, and due to increase demand for radiopharmaceuticals in Brazil, started F18-FDG production in 1999. Cyclotron Laboratory will be a reference Research and Developing Center in our country and will help the Brazilian and Latin-American community. It is necessary to have an adequate database to allow regular follow up and analysis of the individual dose distributions for each group involved in the cyclotron activities. These databases are also important means to assess the effectiveness of efforts in order to maintain doses ALARA and reduce inequalities. The official individual occupational dosimetry is provided by certified Laboratory of Thermoluminescent Dosimetry at IPEN-CNEN/SP. This paper describes the occupational doses distribution in Laboratory of Cyclotrons at IPEN-CNEN/SP from January, 1998 to July, 2000 and propose improvements for the future. (author)

  17. Knowledge based operation assist system for JAERI AVF cyclotron

    International Nuclear Information System (INIS)

    Agematsu, T.; Okumura, S.; Yokota, W.; Arakawa, K.; Murakami, T.; Okamura, T.

    1992-01-01

    We have developed two operation assist systems for easy and rapid operation of the JAERI AVF cyclotron. One is a knowledge based expert system guiding the sequence of parameter adjustment to inexperienced cyclotron operators. The other is a real-time simulation of the beam trajectories which are calculated from actual operating parameters. It graphically indicates feasible setting range of parameters that satisfies the acceptance of the cyclotron. These systems provide a human interface to adjust the parameters of the cyclotron. (author)

  18. Commissioning of cryogen delivery system for superconducting cyclotron magnet

    International Nuclear Information System (INIS)

    Pal, G.; Nandi, C.; Bhattacharyya, T.K.; Chaudhuri, J.; Bhandari, R.K.

    2005-01-01

    A K-500 superconducting cyclotron is being constructed at VECC Kolkata. The cryogen delivery system distributes liquid helium and liquid nitrogen to the superconducting cyclotron. Liquid helium is required to cool the cyclotron magnet and cryopanels. Liquid nitrogen is used to reduce the capacity of the helium liquefier. This paper describes the system, the current status and the commissioning experiences of cryogen delivery system for cyclotron magnet. (author)

  19. ECR ion source for variable energy cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Bose, D K; Taki, G S; Nabhiraj, P Y; Pal, G; Dasgupta, B; Mallik, C; Das, S K; Bandopadhaya, D K; Bhandari, R K [Variable Energy Cyclotron Centre, Calcutta (India)

    1995-09-01

    Some performance characteristics of 6.4 GHz two stage ECR ion source which was under development at this centre is presented. The present ion source will facilitate acceleration of light heavy ions with the existing k=130 variable energy cyclotron. Multiply charged heavy ion (MCHI) beam from the source will also be utilized for atomic physics studies. Oxygen beam has already been used for ion implantation studies. The external injection system under development is nearing completion. Heavy ion beam from cyclotron is expected by end of 1995. (author).

  20. Cyclotron Lines in Accreting Neutron Star Spectra

    Science.gov (United States)

    Wilms, Jörn; Schönherr, Gabriele; Schmid, Julia; Dauser, Thomas; Kreykenbohm, Ingo

    2009-05-01

    Cyclotron lines are formed through transitions of electrons between discrete Landau levels in the accretion columns of accreting neutron stars with strong (1012 G) magnetic fields. We summarize recent results on the formation of the spectral continuum of such systems, describe recent advances in the modeling of the lines based on a modification of the commonly used Monte Carlo approach, and discuss new results on the dependence of the measured cyclotron line energy from the luminosity of transient neutron star systems. Finally, we show that Simbol-X will be ideally suited to build and improve the observational database of accreting and strongly magnetized neutron stars.

  1. Den inre och yttre självkänslans betydelse för tendensen att bruka self-handicapping

    OpenAIRE

    Ottosson, Olivia

    2008-01-01

    Självkänsla är något vi ständigt bär med oss och den inverkar på vårt agerande samt våra val i livet. Johnson (2003) delar in självkänslan i två delar den inre och yttre, vilka kan kombineras till fyra personligheter. Forskning har visat att självkänslan samvarierar med tendensen till att bruka self-handicapping. Self-handicapping innebär att människan skapar hinder för sig själv påhittade eller verkliga. Etthundrasju studenter fyllde i en enkät bestående av 58 påståenden, vilken mätte inre, ...

  2. A line-of-sight electron cyclotron emission receiver for electron cyclotron resonance heating feedback control of tearing modes

    DEFF Research Database (Denmark)

    Oosterbeek, J.W.; Bürger, A.; Westerhof, E.

    2008-01-01

    An electron cyclotron emission (ECE) receiver inside the electron cyclotron resonance heating (ECRH) transmission line has been brought into operation. The ECE is extracted by placing a quartz plate acting as a Fabry-Perot interferometer under an angle inside the electron cyclotron wave (ECW) bea...

  3. Building on TR-24 success. Advanced Cyclotron Systems Inc. launches a new cyclotron model

    International Nuclear Information System (INIS)

    Russell Watt; William Gyles; Alexander Zyuzin

    2015-01-01

    ACSI is designing a new 30 MeV cyclotron based on the TR-24. While minimizing changes from the proven TR-24, including maintaining the same outer dimensions, the energy of the cyclotron will be increased to 30 MeV, which will make it the most compact, non-superconducting, 30 MeV cyclotron design to date. Maximum beam current will match the TR-24 at 1 mA. With the size and footprint of a typical low energy PET cyclotron, this system will offer users a cost effective solution for a diversified facility capable of producing a wide spectrum of PET and SPECT radioisotopes for research and commercial distribution. (author)

  4. Image Navigation and Registration (INR) Performance Assessment Tool Set (IPATS) for the GOES-R Advanced Baseline Imager and Geostationary Lightning Mapper

    Science.gov (United States)

    DeLuccia, Frank J.; Houchin, Scott; Porter, Brian C.; Graybill, Justin; Haas, Evan; Johnson, Patrick D.; Isaacson, Peter J.; Reth, Alan D.

    2016-01-01

    The GOES-R Flight Project has developed an Image Navigation and Registration (INR) Performance Assessment Tool Set (IPATS) for measuring Advanced Baseline Imager (ABI) and Geostationary Lightning Mapper (GLM) INR performance metrics in the post-launch period for performance evaluation and long term monitoring. For ABI, these metrics are the 3-sigma errors in navigation (NAV), channel-to-channel registration (CCR), frame-to-frame registration (FFR), swath-to-swath registration (SSR), and within frame registration (WIFR) for the Level 1B image products. For GLM, the single metric of interest is the 3-sigma error in the navigation of background images (GLM NAV) used by the system to navigate lightning strikes. 3-sigma errors are estimates of the 99.73rd percentile of the errors accumulated over a 24 hour data collection period. IPATS utilizes a modular algorithmic design to allow user selection of data processing sequences optimized for generation of each INR metric. This novel modular approach minimizes duplication of common processing elements, thereby maximizing code efficiency and speed. Fast processing is essential given the large number of sub-image registrations required to generate INR metrics for the many images produced over a 24 hour evaluation period. Another aspect of the IPATS design that vastly reduces execution time is the off-line propagation of Landsat based truth images to the fixed grid coordinates system for each of the three GOES-R satellite locations, operational East and West and initial checkout locations. This paper describes the algorithmic design and implementation of IPATS and provides preliminary test results.

  5. Practicability of patient self-testing of oral anticoagulant therapy by the international normalized ratio (INR) using a portable whole blood monitor. A pilot investigation.

    Science.gov (United States)

    Hasenkam, J M; Knudsen, L; Kimose, H H; Grønnesby, H; Attermann, J; Andersen, N T; Pilegaard, H K

    1997-01-01

    The prophylactic efficacy of long-term oral anticoagulant treatment (OAT) has been demonstrated in a number of clinical conditions with increased tendency to thromboembolism, and the number of individuals subjected to OAT in the industrialised world has increased substantially in recent years. Since this therapy requires considerable resources from both the health care system and the patients, the feasibility of patients' self-monitoring and self-management of OAT has been investigated (1,2,3). The anticipated advantages of this approach include improved convenience and compliance for the patient, who may increase his apprehension for managing the treatment. In addition, self-testing allows for more frequent control compared to the conventional out-patient approach. Importantly, a prerequisite for conceiving a safe and operational concept for patient self-management (PSM) is the availability of a portable INR monitoring system with an accuracy, precision, reproducibility, and long-term reliability comparable to standard coagulometric equipment. The purpose of the present study was to evaluate the feasibility of a commercially available INR-monitor. CoaguChek, for patient self-testing, through a step-wise investigation of the performance characteristics of the equipment in the laboratory, in command of the patient, and during self-testing and self-adjustment of treatment at home. Laboratory INR values were used as reference.

  6. Tokamak startup with electron cyclotron heating

    International Nuclear Information System (INIS)

    Holly, D.J.; Prager, S.C.; Shepard, D.A.; Sprott, J.C.

    1980-04-01

    Experiments are described in which the startup voltage in a tokamak is reduced by approx. 60% by the use of a modest amount of electron cyclotron resonance heating power for preionization. A 50% reduction in volt-second requirement and impurity reflux are also observed

  7. Passive cyclotron current drive for fusion plasmas

    International Nuclear Information System (INIS)

    Kernbichler, W.

    1995-01-01

    The creation of toroidal current using cyclotron radiation in a passive way is, together with the well known bootstrap current, an interesting method for stationary current drive in high-temperature fusion reactors. Here, instead of externally applied RF-waves, fish-scale like structures at the first wall help to create enough asymmetry in the self generated cyclotron radiation intensity to drive a current within the plasma. The problem of computing passive cyclotron current drive consists of actually two linked problems, which are the computation of the electron equilibrium under the presence of self-generated radiation, and the computation of the photon equilibrium in a bounded system with a distorted electron distribution. This system of integro-differential equations cannot be solved directly in an efficient way. Therefore a linearization procedure was developed to decouple both sets of equations, finally linked through a generalized local current drive efficiency. The problem of the exact accounting for the wall profile effects was reduced to the solution of a Fredholm-type integral equation of the 2 nd -kind. Based on all this an extensive computer code was developed to compute the passively driven current as well as radiation losses, radiation transport and overall efficiencies. The results therefrom give an interesting and very detailed insight into the problems related to passive cyclotron current drive

  8. Radioisotope production with a medical cyclotron

    International Nuclear Information System (INIS)

    Silvester, D.J.

    1974-01-01

    The cyclotron of Hammersmith hospital in England was completed and started the operation in 1955. The feature is in its design operable at high beam current, reaching 500μA in internal beam and 300μA in external beam. In 1960's, twelve nuclides of radioactive pharmaceuticals were produced with the cyclotron. C-11, N-13 and O-15 have been used in the form of radioactive gases such as CO or H 2 O to test lung functions. F-18 has been used for bone scanning. K-43 is employed in the research of electrolyte balancing together with Na-24 and Br-77. Fe-52 is utilized in iron ion researches as a tracer. Cs-129 is highly evaluated as an isotope for imaging cardiac clogging part. Radioisotopes must be much more used in the examination of in vivo metabolic function. For this purpose, peculiarly labelled compounds should be further developed. It is welcome that the persons paying attention to the medical prospect of cyclotrons are increasing. The author hopes to continue his endeavour to find new products made with the cyclotron for human welfare. (Wakatsuki, Y.)

  9. Ion-cyclotron instability in magnetic mirrors

    International Nuclear Information System (INIS)

    Pearlstein, L.D.

    1987-01-01

    This report reviews the role of ion-cyclotron frequency instability in magnetic mirrors. The modes discussed here are loss-cone or anisotropy driven. The discussion includes quasilinear theory, explosive instabilities of 3-wave interaction and non-linear Landau damping, and saturation due to non-linear orbits

  10. The Data Cyclotron query processing scheme

    NARCIS (Netherlands)

    Goncalves, R.; Kersten, M.

    2011-01-01

    A grand challenge of distributed query processing is to devise a self-organizing architecture which exploits all hardware resources optimally to manage the database hot set, minimize query response time, and maximize throughput without single point global coordination. The Data Cyclotron

  11. The Data Cyclotron query processing scheme.

    NARCIS (Netherlands)

    R.A. Goncalves (Romulo); M.L. Kersten (Martin)

    2011-01-01

    htmlabstractA grand challenge of distributed query processing is to devise a self-organizing architecture which exploits all hardware resources optimally to manage the database hot set, minimize query response time, and maximize throughput without single point global coordination. The Data Cyclotron

  12. Cyclotron-based neutron source for BNCT

    Energy Technology Data Exchange (ETDEWEB)

    Mitsumoto, T.; Yajima, S.; Tsutsui, H.; Ogasawara, T.; Fujita, K. [Sumitomo Heavy Industries, Ltd (Japan); Tanaka, H.; Sakurai, Y.; Maruhashi, A. [Kyoto University Research Reactor Institute (Japan)

    2013-04-19

    Kyoto University Research Reactor Institute (KURRI) and Sumitomo Heavy Industries, Ltd. (SHI) have developed a cyclotron-based neutron source for Boron Neutron Capture Therapy (BNCT). It was installed at KURRI in Osaka prefecture. The neutron source consists of a proton cyclotron named HM-30, a beam transport system and an irradiation and treatment system. In the cyclotron, H- ions are accelerated and extracted as 30 MeV proton beams of 1 mA. The proton beams is transported to the neutron production target made by a beryllium plate. Emitted neutrons are moderated by lead, iron, aluminum and calcium fluoride. The aperture diameter of neutron collimator is in the range from 100 mm to 250 mm. The peak neutron flux in the water phantom is 1.8 Multiplication-Sign 109 neutrons/cm{sup 2}/sec at 20 mm from the surface at 1 mA proton beam. The neutron source have been stably operated for 3 years with 30 kW proton beam. Various pre-clinical tests including animal tests have been done by using the cyclotron-based neutron source with {sup 10}B-p-Borono-phenylalanine. Clinical trials of malignant brain tumors will be started in this year.

  13. <600> MeV synchro-cyclotron

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    One of the 14 pancakes of the new magnet coils for the 600 MeV synchro-cyclotron which were wound and coated with epoxy resin on the CERN site. These new coils will replace the present ones which have been in use for more than 14 years but are now showing signs of deteriorations.

  14. Helical axial injection concept for cyclotrons

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, E.D.

    1981-01-01

    A concept for an external beam injection system using a helical beam path centered on the cyclotron axis is described. This system could be used to couple two accelerator stages, with or without intermediate stripping, in cases where conventional axial injection or radial injection are not practical.

  15. Helical axial injection concept for cyclotrons

    International Nuclear Information System (INIS)

    Hudson, E.D.

    1981-01-01

    A concept for an external beam injection system using a helical beam path centered on the cyclotron axis is described. This system could be used to couple two accelerator stages, with or without intermediate stripping, in cases where conventional axial injection or radial injection are not practical

  16. Automated cyclotron tuning using beam phase measurements

    International Nuclear Information System (INIS)

    Timmer, J.H.; Roecken, H.; Stephani, T.; Baumgarten, C.; Geisler, A.

    2006-01-01

    The ACCEL K250 superconducting cyclotron is specifically designed for the use in proton therapy systems. The compact medical 250 MeV proton accelerator fulfils all present and future beam requirements for fast scanning treatment systems and is delivered as a turn key system; no operator is routinely required. During operation of the cyclotron heat dissipation of the RF system induces a small drift in iron temperature. This temperature drift slightly detunes the magnetic field and small corrections must be made. A non-destructive beam phase detector has been developed to measure and quantify the effect of a magnetic field drift. Signal calculations were made and the design of the capacitive pickup probe was optimised to cover the desired beam current range. Measurements showed a very good agreement with the calculated signals and beam phase can be measured with currents down to 3 nA. The measured phase values are used as input for a feedback loop controlling the current in the superconducting coil. The magnetic field of the cyclotron is tuned automatically and online to maintain a fixed beam phase. Extraction efficiency is thereby optimised continuously and activation of the cyclotron is minimised. The energy and position stability of the extracted beam are well within specification

  17. A visual assistance environment for cyclotron operation

    International Nuclear Information System (INIS)

    Okamura, Tetsuya; Murakami, Tohru; Agematsu, Takashi; Okumura, Susumu; Arakawa, Kazuo.

    1993-01-01

    A computer-based operation system for a cyclotron which assists inexperienced operators has been developed. Cyclotron start-up operations require dozens of adjustable parameters to be finely tuned to maximize extracted beam current. The human interfaces of the system provide a visual environment designed to enhance beam parameter adjustments. First, the mental model of operators is analyzed. It is supposed to be composed of five partial mental models: beam behavior model, feasible setting regions model, parameter sensitivity model, parameter mutual relation model, and status map model. Next, based on these models, three visual interfaces are developed, i.e., (1) Beam trajectory is rapidly calculated and graphically displayed whenever the operators change the cyclotron parameters. (2) Feasible setting regions (FSR) of the parameters that satisfy the cyclotron's beam acceptance criteria are indicated. (3) Search traces, being a historical visual map of beam current values, are superimposed on the FSRs. Finally, to evaluate system effectiveness, the search time required to reach maximum beam current conditions was measured. In addition, system operability was evaluated using written questionnaires. Results of the experiment showed that the search time to reach specific beam conditions was reduced by approximately 65% using these interfaces. The written questionnaires survey showed the operators highly evaluate system operability. (author)

  18. Microwave power coupling with electron cyclotron resonance ...

    Indian Academy of Sciences (India)

    600 W microwave power with an average electron density of ∼ 6 × 1011 cm. −3 ... the angular frequency of the cyclotron motion, e is the electron charge, m is the mass of .... is also suitable for ECR plasma-based applications like high-quality ...

  19. Development of HM12 cyclotron for PET

    International Nuclear Information System (INIS)

    Morita, Takuzo; Kawama, Tetsuo; Fujii, Kazuo

    2000-01-01

    In Japan, there are at present more than 30 PET (Positron Emission Tomography) facilities. The movements of medical insurance application to the PET diagnosis using [ 18 F] FDG (2-[ 18 F]-fluoro-2-deoxy-glucose) by the Ministry of Health and Welfare are being enhanced by PET related people. Therefore, more clinical centers using PET system are expected to be built in the near future. HM12 cyclotron was developed to meet such market demands for PET, and the prototype machine has been rent to Cyclotron Radio Isotope Center (CYRIC) of Tohoku University since Oct. 1998 for their use of clinical research with positron emitters like 11 C, 13 N, 15 O and 18 F. We got many technical data of HM12 Cyclotron on the clinical base. The data was enough to establish the reliability of HM12 system operation under the clinical condition. The first commercial product of HM12 Cyclotron was delivered to National Cancer Center in March 2000. The final performance test will be finished by the end of June 2000. (author)

  20. Electron cyclotron emission from thermal plasmas

    International Nuclear Information System (INIS)

    Fidone, I.; Granata, G.

    1978-02-01

    Electron cyclotron radiation from a warm inhomogeneous plasma is investigated. A direct calculation of the emissive power of a plasma slab is performed using Rytov's method and the result is compared with the solution of the transfer equation. It is found that, for arbitrary directions of emission, the two results differ, which reflects the fact that Kirchhoff's law is not generally obeyed

  1. Electron cyclotron heating and associated parallel cooling

    International Nuclear Information System (INIS)

    Rapozo, C. da C.; Assis, A.S. de; Busnardo Neto, J.

    1990-01-01

    It has been experimentally observed that during the electron-cyclotron heating the electron longitudinal temperature drops as the perpendicular temperature increases. The experiment was carried in a linear mirror machine with a low density (10 10 cm -3 ) weakly ionized (< 1.0 %) plasma. (Author)

  2. On Resonant Heating Below the Cyclotron Frequency

    International Nuclear Information System (INIS)

    Chen, Liu; Lin, Zhihong; White, R.

    2001-01-01

    Resonant heating of particles by an electrostatic wave propagating perpendicular to a confining uniform magnetic field is examined. It is shown that, with a sufficiently large wave amplitude, significant perpendicular stochastic heating can be obtained with wave frequency at a fraction of the cyclotron frequency

  3. Emergency situation in a medical cyclotron facility

    International Nuclear Information System (INIS)

    Kumar, Rajeev; Bhat, M.K.; Singh, D.K.; Pthania, B.S.; Pandit, A.G.; Jacob, M.J.

    2010-01-01

    Full text: Medical cyclotron is a particle accelerator used in producing short lived radioisotopes such as 18 F, 11 C, 15 O, 13 N, 18 F-2 gas etc. Positron Emission Tomography (PET) is a nuclear imaging modality that has rapidly gained favour. 18 F-FDG is the most widely used radiopharmaceutical with a half-life of 109.8 min. Having more than five years experience in this field we face lots of emergency conditions in the medical cyclotron facility. On the basis of harm we have divided in to three categories i.e. Harm of (a) working personnel, (b) Equipment and (c) environment. Radioactive gas leak and Target foil rupture is considered as the major emergency situations during medical cyclotron operations because there is a potential of over exposure to the working personnel. Radiation protection survey of a self-shielded medical cyclotron installation was carried out during normal and emergency conditions. It is found that the induced activity in the target foil increases with its successive usages. Recommendations have also been made to reduce personal exposure while handling the radioactive gas leak and target foil rupture conditions

  4. Electron-cyclotron-resonance ion sources (review)

    International Nuclear Information System (INIS)

    Golovanivskii, K.S.; Dougar-Jabon, V.D.

    1992-01-01

    The physical principles are described and a brief survey of the present state is given of ion sources based on electron-cyclotron heating of plasma in a mirror trap. The characteristics of ECR sources of positive and negative ions used chiefly in accelerator technology are presented. 20 refs., 10 figs., 3 tabs

  5. Currents driven by electron cyclotron waves

    International Nuclear Information System (INIS)

    Karney, C.F.F.; Fisch, N.J.

    1981-07-01

    Certain aspects of the generation of steady-state currents by electron cyclotron waves are explored. A numerical solution of the Fokker-Planck equation is used to verify the theory of Fisch and Boozer and to extend their results into the nonlinear regime. Relativistic effects on the current generated are discussed. Applications to steady-state tokamak reactors are considered

  6. Tokamak startup with electron cyclotron heating

    Energy Technology Data Exchange (ETDEWEB)

    Holly, D J; Prager, S C; Shepard, D A; Sprott, J C

    1980-04-01

    Experiments are described in which the startup voltage in a tokamak is reduced by approx. 60% by the use of a modest amount of electron cyclotron resonance heating power for preionization. A 50% reduction in volt-second requirement and impurity reflux are also observed.

  7. Cyclotron resonance cooling by strong laser field

    International Nuclear Information System (INIS)

    Tagcuhi, Toshihiro; Mima, Kunioka

    1995-01-01

    Reduction of energy spread of electron beam is very important to increase a total output radiation power in free electron lasers. Although several cooling systems of particle beams such as a stochastic cooling are successfully operated in the accelerator physics, these cooling mechanisms are very slow and they are only applicable to high energy charged particle beams of ring accelerators. We propose here a new concept of laser cooling system by means of cyclotron resonance. Electrons being in cyclotron motion under a strong magnetic field can resonate with circular polarized electromagnetic field, and the resonance take place selectively depending on the velocity of the electrons. If cyclotron frequency of electrons is equal to the frequency of the electromagnetic field, they absorb the electromagnetic field energy strongly, but the other electrons remain unchanged. The absorbed energy will be converted to transverse kinetic energy, and the energy will be dumped into the radiation energy through bremastrahlung. To build a cooling system, we must use two laser beams, where one of them is counter-propagating and the other is co-propagating with electron beam. When the frequency of the counter-propagating laser is tuned with the cyclotron frequency of fast electrons and the co-propagating laser is tuned with the cyclotron frequency of slow electrons, the energy of two groups will approach and the cooling will be achieved. We solve relativistic motions of electrons with relativistic radiation dumping force, and estimate the cooling rate of this mechanism. We will report optimum parameters for the electron beam cooling system for free electron lasers

  8. PT and INR Test

    Science.gov (United States)

    ... Plasma Free Metanephrines Platelet Count Platelet Function Tests Pleural Fluid Analysis PML-RARA Porphyrin Tests Potassium Prealbumin ... and vitamin K (either in a multivitamin or liquid nutrition supplement) may decrease PT. Certain foods, such ...

  9. Directory of cyclotrons used for radionuclide production in Member States

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    The directory of cyclotrons used for radionuclide production is an update of the data base on cyclotrons that was compiled in 1983 by the International Atomic Energy Agency. The directory contains technical, utilization and administrative information supplied to the IAEA as of October 1997. The directory was prepared through information collected by questionnaires sent to institutions that either have a cyclotron, or that were identified to be in the process of installation of a cyclotron. The directory contains 206 entries for cyclotrons operating in 34 Member States. The largest concentration of cyclotrons for radionuclide production are located in the United States of America (66), Japan (33) and Germany (22). The largest number of cyclotrons for a single country is the United States of America. The expansion in number of cyclotrons during the last decade has been driven by the advent of advances in medical imaging instrumentation (PET, SPET and more recently 511 KeV emission tomography); introduction of user friendly compact medical cyclotrons from several companies that manufacture cyclotrons; and recent decisions that {sup 15}O-oxygen PET studies in Japan, and {sup 18}F-FDG PET studies in Germany are eligible for reimbursement by government or insurance companies.

  10. Directory of cyclotrons used for radionuclide production in Member States

    International Nuclear Information System (INIS)

    1998-03-01

    The directory of cyclotrons used for radionuclide production is an update of the data base on cyclotrons that was compiled in 1983 by the International Atomic Energy Agency. The directory contains technical, utilization and administrative information supplied to the IAEA as of October 1997. The directory was prepared through information collected by questionnaires sent to institutions that either have a cyclotron, or that were identified to be in the process of installation of a cyclotron. The directory contains 206 entries for cyclotrons operating in 34 Member States. The largest concentration of cyclotrons for radionuclide production are located in the United States of America (66), Japan (33) and Germany (22). The largest number of cyclotrons for a single country is the United States of America. The expansion in number of cyclotrons during the last decade has been driven by the advent of advances in medical imaging instrumentation (PET, SPET and more recently 511 KeV emission tomography); introduction of user friendly compact medical cyclotrons from several companies that manufacture cyclotrons; and recent decisions that 15 O-oxygen PET studies in Japan, and 18 F-FDG PET studies in Germany are eligible for reimbursement by government or insurance companies

  11. Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency.

    Science.gov (United States)

    Nagornov, Konstantin O; Kozhinov, Anton N; Tsybin, Yury O

    2017-04-01

    The phenomenon of ion cyclotron resonance allows for determining mass-to-charge ratio, m/z, of an ensemble of ions by means of measurements of their cyclotron frequency, ω c . In Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), the ω c quantity is usually unavailable for direct measurements: the resonant state is located close to the reduced cyclotron frequency (ω + ), whereas the ω c and the corresponding m/z values may be calculated via theoretical derivation from an experimental estimate of the ω + quantity. Here, we describe an experimental observation of a new resonant state, which is located close to the ω c frequency and is established because of azimuthally-dependent trapping electric fields of the recently developed ICR cells with narrow aperture detection electrodes. We show that in mass spectra, peaks close to ω + frequencies can be reduced to negligible levels relative to peaks close to ω c frequencies. Due to reduced errors with which the ω c quantity is obtained, the new resonance provides a means of cyclotron frequency measurements with precision greater than that achieved when ω + frequency peaks are employed. The described phenomenon may be considered for a development into an FT-ICR MS technology with increased mass accuracy for applications in basic research, life, and environmental sciences. Graphical Abstract ᅟ.

  12. Radiation protection of cyclotron vault with maze in PET Cyclotron Center

    International Nuclear Information System (INIS)

    Fueloep, Marko

    2003-01-01

    The PET Cyclotron center (PCC) is a complex for production, research and application of positron radiopharmaceuticals for PET (Positron Emission Tomography), which was commissioned this year (2004) in Bratislava, Slovak Republic. Positron radionuclides are produced by 18/9 MeV proton/deuteron cyclotron CYCLONE 18/9. Radiation protection of personnel and inhabitants against ionizing radiation in the PCC is solved with regard to the ICRP recommendations and Slovak regulatory system, protection rules and criteria and optimization of radiation protection. In the article comparisons of calculated and measured neutron and gamma dose equivalent rates around the CYCLONE 18/9 and at various points behind the shielding of cyclotron vault with maze are presented. Description of the CYCLONE 18/9 as a source of angular distribution of neutron energy spectra (production of 18 F was considered) was simulated by Monte Carlo code MCNPX. Code MCNP4B was used for shielding calculation of cyclotron vault with maze. Neutron energy spectra behind the shielding were measured by Bonner spectrometer. The values of neutron dose equivalent, which were calculated and measured around the CYCLONE 18/9 and at various points behind the shielding of cyclotron vault with maze, are within the range of factor 2. (authors)

  13. The Cyclotron Center of the Slovak Republic

    International Nuclear Information System (INIS)

    Podhorsky, D.; Ruzicka, J.; Macasek, F.; Makaiova, I.; Saro, S.; Kristiak, J.; Fulup, M.

    2001-01-01

    The Cyclotron Center of the Slovak Republic was established at the beginning of August 1999 - within the Slovak-Office of Standards, Metrology and Testing (SOSMT), in Bratislava, Slovak Republic. It will have two cyclotrons - a large heavy and light cyclotron DC-72, which will be constructed by the Joint Institute for Nuclear Research (JINR), Dubna, Russian Federation, and a small commercial light ion cyclotron IBA 18/9. The heavy ion source of the electron resonance type (DECRS-2M) will be used for low and medium energy experiments in physics. The small electron accelerator is planned for different applications, including improving the properties of plastics, increasing the resistance of cables to fire and temperature, the sterilization of medical disposables in the CC SR. The main purpose of the Cyclotron Center of the Slovak Republic (CC SR) is to catch the present approach and trends in the area of improving of inhabitants life and health quality using the progressive technology, which is introduced by bringing into practice of the physical equipment - accelerators, producing beams of high energy particles. Experts of nuclear physics and of the related branches have no experimental basis in Slovakia, as after dissolution of the former the Czech and Slovak Federal Republic all bigger nuclear equipment were left in the Czech Republic. The Slovak Republic is one of the European countries where cancer and cardiovascular diseases have a rapidly increasing tendency (the rate of new oncological cases is approximately 20,000/year at the population of 5 million inhabitants) - early diagnostics of population is necessary to be updated urgently. The Slovak Republic use a great part of electricity (about 60 %) from its own nuclear power stations and thus it is in need of education of rising generations of experts from different nuclear fields. The Government of the Slovak republic on June 18, 1996 approved the strategic aim of building up the Cyclotron Laboratory at the

  14. Research and education by SF cyclotron facility

    International Nuclear Information System (INIS)

    1992-04-01

    This report represents the current activities in research and education using the cyclotron facility and related apparatus which are supported by Nuclear Physics Division and this is a continuation of INS-T-466 (1986, December). In this version an iron-free β-ray spectrometer and a cooler-synchrotron (TARN II) are briefly described also in the first chapter. The second chapter explains experimental programs performed in the last 5 years. The third chapter gives the number of publications on researches performed in 1975-1991, and also gives twelve topics obtained from the cyclotron and the β-ray spectrometer in recent 5 years. The last chapter provides the whole list of the works for Doctor and Master theses performed at the facility in the last 10 years. (J.P.N.)

  15. MMS Observations of Harmonic Electromagnetic Cyclotron Waves

    Science.gov (United States)

    Usanova, M.; Ahmadi, N.; Ergun, R.; Trattner, K. J.; Fuselier, S. A.; Torbert, R. B.; Mauk, B.; Le Contel, O.; Giles, B. L.; Russell, C. T.; Burch, J.; Strangeway, R. J.

    2017-12-01

    Harmonically related electromagnetic ion cyclotron waves with the fundamental frequency near the O+ cyclotron frequency were observed by the four MMS spacecraft on May 20, 2016. The wave activity was detected by the spacecraft on their inbound passage through the Earth's morning magnetosphere during generally quiet geomagnetic conditions but enhanced solar wind dynamic pressure. It was also associated with an enhancement of energetic H+ and O+ ions. The waves are seen in both magnetic and electric fields, formed by over ten higher order harmonics, most pronounced in the electric field. The wave activity lasted for about an hour with some wave packets giving rise to short-lived structures extending from Hz to kHz range. These observations are particularly interesting since they suggest cross-frequency coupling between the lower and higher frequency modes. Further work will focus on examining the nature and role of these waves in the energetic particle dynamics from a theoretical perspective.

  16. Neutron radiography with the cyclotron, 3

    International Nuclear Information System (INIS)

    Hiraoka, Eiichi; Fujishiro, Masatoshi; Tsujii, Yukio

    1985-01-01

    Neutron radiography is well recognized as a powerful tool in nondestructive testing, but not widely used yet owing to lack of high intense thermal neutron source convenient for practical use. A new neutron radiograph facility, utilizing a sub-compact cyclotron as neutron source and equipped with vertical and horizontal irradiation ports, is presented in this article. A series of experiment, prior to its construction, was conducted using beams of a variable energy cyclotron at Tohoku University to investigate the characteristics of thermal neutron obtained, from 9 Be (p, n) reaction and thermalized by elastic scattering process. This article describes a computer simulation of neutron moderator to analyze conditions getting maximal thermal neutron flux. Some of practical neutron radiograph examination of aero-space components and museum art objects of classic bronze mirror are also presented together with an attempt realizing real time imaging technique. (author)

  17. Research activities by INS cyclotron facility

    International Nuclear Information System (INIS)

    1992-06-01

    Research activities made by the cyclotron facility and the related apparatuses at Institute for Nuclear Study (INS), University of Tokyo, have been reviewed in terms of the associated scientific publications. This publication list, which is to be read as a continuation of INS-Rep.-608 (October, 1986), includes experimental works on low-energy nuclear physics, accelerator technology, instrumental developments, radiation physics and other applications in interdisciplinary fields. The publications are classified into the following four categories. (A) : Internal reports published in INS. (B) : Publications in international scientific journals on experimental research works done by the cyclotron facility and the related apparatuses at INS. Those made by outside users are also included. (C) : Publications in international scientific journals on experimental low-energy nuclear physics, which have been done by the staff of INS Nuclear Physics Division using facilities outside INS. (D) : Contributions to international conferences. (author)

  18. New design for a medical cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, M

    1985-12-01

    The Oxford Instruments Group PLC, have designed a 30 MeV energy proton cyclotron incorporating a super-conducting magnet and a novel RF accelerating cavity. The energy range is suitable for the production of isotopes such as /sup 67/Ga, /sup 111/In, /sup 123/I and /sup 201/Tl, and the short lived isotopes of carbon, nitrogen, oxygen and fluorine for use in Positron Emmission Tomography (PET). A new magnet and RF cavity design permit a considerable power and weight reduction and a compact size (1.5m dia x 1.9m high), allowing the cyclotron to be transported to a shielded site as an assembly after factory testing. A method of beam extraction has been adopted which minimises activation of the accelerator components and so allows hands on maintenance to be carried out when required.

  19. Matching of ion sources to cyclotron inflectors

    International Nuclear Information System (INIS)

    Baartman, R.

    1988-06-01

    In general, cyclotron inflectors strongly couple the two transverse subspaces. This leads to a growth in emittance projections for a beam with no initial correlation between the two transverse subspaces. Only in the case of the Mueller (hyperboloid) inflector is there no emittance growth. We have made calculations using an optimization routine to match a given beam through the axial injection system. We find that in the limit where all the emittance is due to a beam's axial angular momentum (for example, from an ECR source), matching with no emittance growth is possible even in the case of mirror or spiral inflectors. Moreover, any one of the two transverse emittances circulating in the cyclotron can be made smaller than the source emittance while maintaining the sum of the emittances constant. This is achieved by rotating the matching quadrupoles with respect to the inflector and retuning

  20. Cyclotrons as Drivers for Precision Neutrino Measurements

    International Nuclear Information System (INIS)

    Alonso, J.; Barletta, W. A.; Winslow, L. A.; Shaevitz, M. H.; Spitz, J.; Conrad, J. M.; Toups, M.; Adelmann, A.

    2014-01-01

    As we enter the age of precision measurement in neutrino physics, improved flux sources are required. These must have a well defined flavor content with energies in ranges where backgrounds are low and cross-section knowledge is high. Very few sources of neutrinos can meet these requirements. However, pion/muon and isotope decay-at-rest sources qualify. The ideal drivers for decay-at-rest sources are cyclotron accelerators, which are compact and relatively inexpensive. This paper describes a scheme to produce decay-at-rest sources driven by such cyclotrons, developed within the DAEδALUS program. Examples of the value of the high precision beams for pursuing Beyond Standard Model interactions are reviewed. New results on a combined DAEδALUS—Hyper-K search for CP violation that achieve errors on the mixing matrix parameter of 4° to 12° are presented

  1. Hybrid simulation of electron cyclotron resonance heating

    Energy Technology Data Exchange (ETDEWEB)

    Ropponen, T. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, FI-40014 (Finland)], E-mail: tommi.ropponen@phys.jyu.fi; Tarvainen, O. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Suominen, P. [CERN Geneve 23, CH-1211 (Switzerland); Koponen, T.K. [Department of Physics, University of Jyvaeskylae, Nanoscience Center, P.O. Box 35, FI-40014 (Finland); Kalvas, T.; Koivisto, H. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, FI-40014 (Finland)

    2008-03-11

    Electron Cyclotron Resonance (ECR) heating is a fundamentally important aspect in understanding the physics of Electron Cyclotron Resonance Ion Sources (ECRIS). Absorption of the radio frequency (RF) microwave power by electron heating in the resonance zone depends on many parameters including frequency and electric field strength of the microwave, magnetic field structure and electron and ion density profiles. ECR absorption has been studied in the past by e.g. modelling electric field behaviour in the resonance zone and its near proximity. This paper introduces a new ECR heating code that implements damping of the microwave power in the vicinity of the resonance zone, utilizes electron density profiles and uses right hand circularly polarized (RHCP) electromagnetic waves to simulate electron heating in ECRIS plasma.

  2. Electron cyclotron emission from the PLT tokamak

    International Nuclear Information System (INIS)

    Hosea, J.; Arunasalam, V.; Cano, R.

    1977-07-01

    Experimental measurements of electron cyclotron emission from the PLT tokamak plasma reveal that black-body emission occurs at the fundamental frequency. Such emission, not possible by direct thermal excitation of electromagnetic waves, is herein attributed to thermal excitation of electrostatic (Bernstein) waves which then mode convert into electromagnetic waves. The local feature of the electrostatic wave generation permits spatially and time resolved measurements of electron temperature as for the second harmonic emission

  3. Use of maze in cyclotron hoppers

    International Nuclear Information System (INIS)

    Fernandes, Fernando A.; Alves, Juliano S.; Fochesatto, Cintia; Cerioli, Luciane; Borges, Joao Alfredo; Gonzalez, Delfin; Silva, Daniel C.

    2013-01-01

    Introduction: the increasing number of cyclotrons in Brazil due to constitutional amendment 49 /06 that enabled the production of radiopharmaceuticals with a short half - life by private companies. The radionuclides used for PET - CT require production centers near or within the diagnostic centers. In order to minimize maintenance and operating risks, gaining efficiency, our facility was the first in Brazil to use the access to a cyclotron bunker via maze, rather than armored door stopper type. Materials: the design calculations were based on the Monte Carlo method (MCNP5 - Monte Carlo N-Particletransportcode version 5). At the ends of the labyrinth are installed a door of polyethylene, for thermalization of neutrons, and other of wood for limiting access. Both legs of the maze have wall thickness of 100cm. In inspection Brazilian CNEN realize measures of dose rate for neutrons and gamma 9 points: 7 around the bunker, 1 over the bunker and 1 in the exhaust with the cyclotron operating with maximum load, double beam of 50uA for 2 hours. After commissioning were carried out around the bunker, the following measures: cumulative dose in three months with dosimeters for neutron rate dose with a gas proportional detector type filled with 3 He and polyethylene neutron moderator and dose rate with a Geiger - Mueller detector for gamma radiation. Readings with neutron detectors were classified as background radiation and dose rates were always below the limits established in standard EN 3.01, and the calculation of the predicted regardless of the intensity of irradiation inside the bunker. Conclusion: the use of labyrinths as a way to access the bunkers cyclotron has been shown to be effective as the radiation shielding and efficient by allowing quick and easy access, virtually eliminating the maintenance

  4. The superconducting separated orbit cyclotron TRITRON

    International Nuclear Information System (INIS)

    Trinks, U.

    1984-01-01

    At the Munich 13 MV-Tandem Laboratory the TRITRON is under development, which will be the prototype of a superconducting separated orbit cyclotron for acceleration of heavy ions with 0.04 or approx.20) of the revolution frequency. Thus the frequency range for acceleration of ions with different revolution frequency can be kept small (+-3%). The magnets as well as the cavities are contained in the same cavity. (orig.)

  5. DAISY - the Oslo Cyclotron data acquisition system

    International Nuclear Information System (INIS)

    Ramsoey, T.

    1991-08-01

    The new CACTUS multidetector system for the Oslo Cyclotron consists of 8 particle telescopes, 28 NAI detectors and 2 Ge detectors. Each detector gives rise to one energy parameter and one time parameter. Thus, a total of 80 parameters are present. The counting rate is 100 kByte/s for the highest beam intensities. A new data acquisition system, DAISY, satisfying these demands has been designed. The present report is intended as a complete technical manual for the new system. 24 refs

  6. Electron cyclotron resonance multiply charged ion sources

    International Nuclear Information System (INIS)

    Geller, R.

    1975-01-01

    Three ion sources, that deliver multiply charged ion beams are described. All of them are E.C.R. ion sources and are characterized by the fact that the electrons are emitted by the plasma itself and are accelerated to the adequate energy through electron cyclotron resonance (E.C.R.). They can work without interruption during several months in a quasi-continuous regime. (Duty cycle: [fr

  7. Cyclotron heating rate in a parabolic mirror

    International Nuclear Information System (INIS)

    Smith, P.K.

    1984-01-01

    Cyclotron resonance heating rates are found for a parabolic magnetic mirror. The equation of motion for perpendicular velocity is solved, including the radial magnetic field terms neglected in earlier papers. The expression for heating rate involves an infinite series of Anger's and Weber's functions, compared with a single term of the unrevised expression. The new results show an increase of heating rate compared with previous results. A simple expression is given for the ratio of the heating rates. (author)

  8. First experimental observation of cyclotron superradiance

    Energy Technology Data Exchange (ETDEWEB)

    Ginzburg, N S; Zotova, I V; Sergeev, A S; Konoplev, I V [Russian Academy of Sciences, Nizhny Novgorod (Russian Federation). Inst. of Applied Physics; Shpak, V G; Yalandin, M I; Shunajlov, C A; Ulmaskulov, M P [Russian Academy of Sciences, Ekaterinburg (Russian Federation). Inst. of Electrophysics

    1997-12-31

    The first experimental observation of cyclotron superradiance from subnanosecond high-current electron bunches moving through waveguide systems is reported. Ultrashort microwave K{sub {alpha}} band pulses with a power of 200 kW and duration less than 0.5 ns were observed in the regime of group synchronism when the electron bunch drift velocity coincided with the group velocity of the electromagnetic waves. (author). 2 figs., 13 refs.

  9. Electron cyclotron emission measurement in Tore Supra

    International Nuclear Information System (INIS)

    Javon, C.

    1991-06-01

    Electron cyclotron radiation from Tore-Supra is measured with Michelson and Fabry-Perot interferometers. Calibration methods, essential for this diagnostic, are developed allowing the determination of electron temperature in the plasma. In particular the feasibility of Fabry-Perot interferometer calibration by an original method is demonstrated. A simulation code is developed for modelling non-thermal electron population in these discharges using measurements in non-inductive current generation regime [fr

  10. Modular beam diagnostics instrument design for Cyclotrons

    International Nuclear Information System (INIS)

    Chaddha, N.; Bhole, R.B.; Sahoo, S.; Nandy, P.P.; Pal, S.

    2012-01-01

    The Cyclotrons at VECC, Kolkata i.e. Room Temperature Cyclotron (RTC) and Superconducting Cyclotron (SCC) comprise of internal and external Beam Diagnostic systems. These systems provide the beam developer with position, intensity, beam profile, a visual impression of the size and shape of ion beam, and operational control over diagnostic components like 3-finger probe, Beam Viewer probe, Deflector probe, Faraday cup, X-Y slit, Beam viewer etc. Automation of these components was initially done using customised modules for individual sub-system. An expansion of this facility and various levels of complexity demand modular design to cater easy modification and upgradation. The overall requirements are analysed and modular cards are developed based on basic functionalities like valve operation, probe/slit/viewer control, position read-out, Interlock, aperture control of beam line and communication. A 32-bit Advanced RISC Machine (ARM) based card with embedded EPICS is chosen as the master controller and FPGA/microcontroller is used for functional modules. The paper gives a comprehensive description of all modules and their integration with the control system. (author)

  11. Ion Cyclotron Heating on Proto-MPEX

    Science.gov (United States)

    Goulding, R. H.; Caughman, J. B. O.; Rapp, J.; Biewer, T. M.; Campbell, I. H.; Caneses, J. F.; Kafle, N.; Ray, H. B.; Showers, M. A.; Piotrowicz, P. A.

    2016-10-01

    Ion cyclotron heating will be used on Proto-MPEX (Prototype Material Plasma Exposure eXperiment) to increase heat flux to the target, to produce varying ion energies without substrate biasing, and to vary the extent of the magnetic pre-sheath for the case of a tilted target. A 25 cm long, 9 cm diameter dual half-turn helical ion cyclotron antenna has been installed in the device located at the magnetic field maximum. It couples power to ions via single pass damping of the slow wave at the fundamental resonance, and operates with ω 0.8ωci at the antenna location. It is designed to operate at power levels up to 30 kW, with a later 200 kW upgrade planned. Near term experiments include measuring RF loading at low power as a function of frequency and antenna gap. The plasma is generated by a helicon plasma source that has achieved ne > 5 ×1019m-3 operating with deuterium, as measured downstream from the ion cyclotron antenna location. Measurements will be compared with 1-D and 2-D models of RF coupling. The latest results will be presented. This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy.

  12. Electron cyclotron heating (ECH) of tokamak plasmas

    International Nuclear Information System (INIS)

    Hoshino, Katsumichi

    1990-01-01

    Electron cyclotron heating (ECH) is one of the intense methods of plasma heating, and which utilizes the collisionless electron-cyclotron-resonance-interaction between the launched electromagnetic waves (called electron cyclotron waves) and electrons which are one of the constituents of the high temperature plasmas. Another constituent, namely the ions which are subject to nuclear fusion, are heated indirectly but strongly and instantly (in about 0.1 s) by the collisions with the ECH-heated electrons in the fusion plasmas. The recent progress on the development of high-power and high-frequency millimeter-wave-source enabled the ECH experiments in the middle size tokamaks such as JFT-2M (Japan), Doublet III (USA), T-10 (USSR) etc., and ECH has been demonstrated to be the sure and intense plasma heating method. The ECH attracts much attention for its remarkable capabilities; to produce plasmas (pre-ionization), to heat plasmas, to drive plasma current for the plasma confinement, and recently especially by the localization and the spatial controllability of its heating zone, which is beneficial for the fine controls of the profiles of plasma parameters (temperature, current density etc.), for the control of the magnetohydrodynamic instabilities, or for the optimization/improvement of the plasma confinement characteristics. Here, the present status of the ECH studies on tokamak plasmas are reviewed. (author)

  13. Nonlinear cyclotron absorption and stimulated scattering

    International Nuclear Information System (INIS)

    Chung, T.H.

    1986-01-01

    In electron cyclotron resonance heating (ECRH), wave sources heating a plasma linearly with respect to intensity; but as the intensity of ECRH gets larger, there might appear nonlinear effects that would result in cutoff of net absorption. This thesis uses quantum mechanical theory to derive a threshold microwave intensity for nonlinear absorption. The quantum mechanical theory estimates that the threshold microwave intensity for nonlinear absorption is about 10 5 watts/cm 2 for a microwave heating experiment (T/sub e/ = 100 ev, λ = 3,783 cm, B = 2.5 kG). This value seems large considering the present power capabilities of microwave sources (10 2 ∼ 10 3 watts/cm 2 ), but for a low temperature plasma, this threshold will go down. There is another nonlinear phenomenon called stimulated cyclotron scattering that enhances photon scattering by electrons gyrating in a magnetic field. This is expected to prevent incoming photons from arriving at the central region of the fusion plasma, where absorption mainly takes place. Theory based on a photon transport model predicts that the threshold intensity for the stimulated cyclotron scattering is about 10 4 watts/cm 2 for the plasma parameters mentioned above. This value seems large also, but a longer wavelength of microwaves and a larger magnitude magnetic field, which will be the case in reactor type facilities, will lower the threshold intensity to levels comparable with the currently developed microwave sources

  14. Transparency of Magnetized Plasma at Cyclotron Frequency

    International Nuclear Information System (INIS)

    G. Shvets; J.S. Wurtele

    2002-03-01

    Electromagnetic radiation is strongly absorbed by a magnetized plasma if the radiation frequency equals the cyclotron frequency of plasma electrons. It is demonstrated that absorption can be completely canceled in the presence of a magnetostatic field of an undulator or a second radiation beam, resulting in plasma transparency at the cyclotron frequency. This effect is reminiscent of the electromagnetically induced transparency (EIT) of the three-level atomic systems, except that it occurs in a completely classical plasma. Unlike the atomic systems, where all the excited levels required for EIT exist in each atom, this classical EIT requires the excitation of the nonlocal plasma oscillation. The complexity of the plasma system results in an index of refraction at the cyclotron frequency that differs from unity. Lagrangian description was used to elucidate the physics and enable numerical simulation of the plasma transparency and control of group and phase velocity. This control naturally leads to applications for electromagnetic pulse compression in the plasma and electron/ion acceleration

  15. Improving cancer treatment with cyclotron produced radionuclides

    International Nuclear Information System (INIS)

    Larson, S.M.; Finn, R.D.

    1992-01-01

    Our goal is to improve the scientific basis for tumor diagnosis, treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. The grant includes 3 interactive components: Radiochemistry/Cyclotron; Pharmacology; and Immunology. The radiochemistry group seeks to develop innovative cyclotron targetry, radiopharmaceuticals, and radiolabeled antibodies, which are then used to assess important unanswered questions in tumor pharmacology and immunology. Examples include selected positron emitting radionuclides, such as Iodine-124, and Ga-66; I-124, I-123, I-131 labeled iododeoxyuridine, C-11 colchicine, and antimetabolites, like C-11 methotrexate; and radiolabeled antibodies, 3F8, M195, A33, and MRK16 for application in the pharmacology and immunology projects. The pharmacology program studies tumor resistance to chemotherapy, particularly the phenomenon of multidrug resistance and the relationship between tumor uptake and retention and the tumor response for anti-metabolite drugs. The immunology program studies the physiology of antibody localization at the tissue level as the basis for novel approaches to improving tumor localization such as through the use of an artificial lymphatic system which mechanically reduces intratumoral pressures in tumors in vivo. Quantitative imaging approaches based on PET and SPECT in radioimmunotherapy are studied to give greater insight into the physiology of tumor localization and dosimetry

  16. Operation of a quasioptical electron cyclotron maser

    International Nuclear Information System (INIS)

    Morse, E.C.; Pyle, R.V.

    1984-12-01

    The electron cyclotron maser or gyrotron concept has been developed to produce sources producing 200 kW at 28 GHz continuously, and higher power outputs and frequencies in pulsed mode. These sources have been useful in electron cyclotron resonance heating (ECRH) in magnetically confined fusion devices. However, higher frequencies and higher power levels will be required in reactor-grade fusion plasmas, with likely requirements of 1.0 MW or more per source at 140 GHz. Conventional gyrotrons follow a trend of decreasing power for increasing frequency. In order to circumvent this problem, the quasioptical electron cyclotron maser was proposed. In this device, the closed resonator of the conventional gyrotron is replaced with an open, Fabry-Perot type resonator. The cavity modes are then the TEM-type modes of an optical laser. The advantage of this configuration is that the cavity size is not a function of frequency, since the length can be any half-integer number of wavelengths. Furthermore, the beam traverses across the cavity transverse to the direction of radiation output, and thus the rf window design is less complicated than in conventional tubes. The rf output, if obtained by diffraction coupling around one of the mirrors, could be in a TEM mode, which would allow for quasioptical transmission of the microwaves into the plasma in fusion devices. 4 references, 1 figure

  17. TFTR vertically viewing electron cyclotron emission diagnostic

    International Nuclear Information System (INIS)

    Taylor, G.

    1990-01-01

    The Tokamak Fusion Test Reactor (TFTR) Michelson interferometer has a spectral coverage of 75--540 GHz, allowing measurement of the first four electron cyclotron harmonics. Until recently the instrument has been configured to view the TFTR plasma on the horizontal midplane, primarily in order to measure the electron temperature profile. Electron cyclotron emission (ECE) extraordinary mode spectra from TFTR Supershot plasmas exhibit a pronounced, spectrally narrow feature below the second harmonic. A similar feature is seen with the ECE radiometer diagnostic below the electron cyclotron fundamental frequency in the ordinary mode. Analysis of the ECE spectra indicates the possibility of a non-Maxwellian 40--80 keV tail on the electron distribution in or near the core. During 1990 three vertical views with silicon carbide viewing targets will be installed to provide a direct measurement of the electron energy distribution at major radii of 2.54, 2.78, and 3.09 m with an energy resolution of approximately 20% at 100 keV. To provide the maximum flexibility, the optical components for the vertical views will be remotely controlled to allow the Michelson interferometer to be reconfigured to either the midplane horizontal view or one of the three vertical views between plasma shots

  18. Diagnostic system for the nuclear medicine with baby cyclotron

    International Nuclear Information System (INIS)

    Kashihara, Masao; Wakasa, Shyuichiro

    1982-01-01

    The system of cyclotron nuclear medicine consists of ''RI-production by using the cyclotron'', ''production of radio-pharmaceuticals labeled with RI'', ''positron tomography''. On the other hand, Ultra compact cyclotron (Baby cyclotron) itself, RI production technique and positron tomography have been rapidly developed and advanced. We think that these three functions must be balance in the development in order to spread this system into the routine work in the hospital. However, since the technology of the synthesis for the labeled compounds is not so developed so far, more advance can be strongly expected. In this report, construction of the cyclotron nuclear medicine, utility for the practical use of RI produced by using the cyclotron, technique of RI production, and the studies on automated and efficient productions of radio-pharmaceuticals labeled with short-lived positron emitters for medical diagnostic use are described. (author)

  19. arXiv Cyclotrons: Magnetic Design and Beam Dynamics

    CERN Document Server

    Zaremba, Simon

    Classical, isochronous, and synchro-cyclotrons are introduced. Transverse and longitudinal beam dynamics in these accelerators are covered. The problem of vertical focusing and iscochronism in compact isochronous cyclotrons is treated in some detail. Different methods for isochronization of the cyclotron magnetic field are discussed. The limits of the classical cyclotron are explained. Typical features of the synchro-cyclotron, such as the beam capture problem, stable phase motion, and the extraction problem are discussed. The main design goals for beam injection are explained and special problems related to a central region with an internal ion source are considered. The principle of a Penning ion gauge source is addressed. The issue of vertical focusing in the cyclotron centre is briefly discussed. Several examples of numerical simulations are given. Different methods of (axial) injection are briefly outlined. Different solutions for beam extraction are described. These include the internal target, extracti...

  20. Calculation of proton beam initial orbit at cyclotron central region

    International Nuclear Information System (INIS)

    Pramudita Anggraita

    2012-01-01

    A calculation of proton beam initial orbits at cyclotron central region was carried out using Scilab 5.2.0. The calculation was done in 2 dimensions in a homogeneous magnetic field of 1.66 tesla at frequency of fourth harmonics. The positions of ion source, dees, and dummy dees follow those of GE Minitrace cyclotron, peak dee voltage 30 kV. The calculation yields result comparable to those simulated at KIRAMS-13 cyclotron. (author)

  1. Suppression of cyclotron instability in Electron Cyclotron Resonance ion sources by two-frequency heating

    International Nuclear Information System (INIS)

    Skalyga, V.; Izotov, I.; Mansfeld, D.; Kalvas, T.; Koivisto, H.; Komppula, J.; Kronholm, R.; Laulainen, J.; Tarvainen, O.

    2015-01-01

    Multiple frequency heating is one of the most effective techniques to improve the performance of Electron Cyclotron Resonance (ECR) ion sources. The method increases the beam current and average charge state of the extracted ions and enhances the temporal stability of the ion beams. It is demonstrated in this paper that the stabilizing effect of two-frequency heating is connected with the suppression of electron cyclotron instability. Experimental data show that the interaction between the secondary microwave radiation and the hot electron component of ECR ion source plasmas plays a crucial role in mitigation of the instabilities

  2. Proceedings of eighth joint workshop on electron cyclotron emission and electron cyclotron resonance heating. Vol. 1

    International Nuclear Information System (INIS)

    1993-03-01

    The theory of electron cyclotron resonance phenomena is highly developed. The main theoretical tools are well established, generally accepted and able to give a satisfactory description of the main results obtained in electron cyclotron emission, absorption and current drive experiments. In this workshop some advanced theoretical and numerical tools have been presented (e.g., 3-D Fokker-Planck codes, treatment of the r.f. beam as a whole, description of non-linear and finite-beam effects) together with the proposal for new scenarios for ECE and ECA measurements (e.g., for diagnosing suprathermal populations and their radial transport). (orig.)

  3. Proceedings of eighth joint workshop on electron cyclotron emission and electron cyclotron resonance heating. Vol. 2

    International Nuclear Information System (INIS)

    1993-03-01

    The theory of electron cyclotron resonance phenomena is highly developed. The main theoretical tools are well established, generally accepted and able to give a satisfactory description of the main results obtained in electron cyclotron emission, absorption and current drive experiments. In this workshop some advanced theoretical and numerical tools have been presented (e.g., 3-D Fokker-Planck codes, treatment of the r.f. beam as a whole, description of non-linear and finite-beam effects) together with the proposal for new scenarios for ECE and ECA measurements (e.g., for diagnosing suprathermal populations and their radial transport). (orig.)

  4. Cyclotron will not survive yet this year without state support

    International Nuclear Information System (INIS)

    Marcan, P.

    2005-01-01

    In this paper the project of the Cyclotron Center of the Slovak republic is described. On the basis of this project the state joint-stock company Biont was constituted. Small cyclotron is in operation; big cyclotron is in process of manufacture and it will be put in operation in 2007. Small cyclotron will be used for production of radiopharmaceuticals. Positron emission tomograph (PET) in Oncological Institute of St. Elizabeth (in Bratislava) and gamma camera in Central Military Hospital (in Ruzomberok) are constituents of the Biont. The PET will be also in Biont. The hadron therapy of ophthalmic tumors is planned. Financial plans of the Biont up to 2009 are presented

  5. The problems of high efficient extraction from the isochronous cyclotron

    International Nuclear Information System (INIS)

    Schwabe, J.

    1994-06-01

    The problem of high efficient extraction (η ≥ 50%) from isochronous cyclotrons (with the exception of the stripping method) is not completely solved up to this day. This problem is specifically important, because these cyclotrons are being also applied in the production of medical radioisotopes, labeled pharmaceuticals as well as in neutron therapy (oncology), machine industry, agriculture (plant mutagenesis), etc. The aim of the proposed topic is to solve this problem on the AIC-144 isochronous cyclotron in the INP (Institute of Nuclear Physics). Lately, a beam of 20 MeV deuterons with an efficiency of ca. 15% was extracted from this cyclotron. (author). 25 refs, 14 figs

  6. Cyclotron based nuclear science. Progress report, April 1, 1985-March 31, 1986

    International Nuclear Information System (INIS)

    Youngblood, D.H.

    1986-08-01

    Progress report for cyclotron based nuclear science cyclotron facility are summarized. Research is described under the headings heavy ion reactions, nuclear theory, atomic studies and activation analysis, superconducting cyclotron and instrumentation. Publications are listed

  7. Benchmarking of codes for electron cyclotron heating and electron cyclotron current drive under ITER conditions

    NARCIS (Netherlands)

    Prater, R.; Farina, D.; Gribov, Y.; Harvey, R. W.; Ram, A. K.; Lin-Liu, Y. R.; Poli, E.; Smirnov, A. P.; Volpe, F.; Westerhof, E.; Zvonkovo, A.

    2008-01-01

    Optimal design and use of electron cyclotron heating requires that accurate and relatively quick computer codes be available for prediction of wave coupling, propagation, damping and current drive at realistic levels of EC power. To this end, a number of codes have been developed in laboratories

  8. Non-vitamin K antagonist oral anticoagulants compared with warfarin at different levels of INR control in atrial fibrillation: A meta-analysis of randomized trials.

    Science.gov (United States)

    Carmo, João; Ferreira, Jorge; Costa, Francisco; Carmo, Pedro; Cavaco, Diogo; Carvalho, Salomé; Morgado, Francisco; Adragão, Pedro; Mendes, Miguel

    2017-10-01

    The efficacy and safety of warfarin for stroke prevention in atrial fibrillation (AF) depend on the time in the therapeutic range (TTR) with an international normalised ratio (INR) of 2.0-3.0. This meta-analysis focused the relative efficacy and safety of non-VKA oral anticoagulants (NOAC) compared with warfarin at different thresholds of centre's TTR (cTTR). We searched PubMed, Embase, CENTRAL and websites of regulatory agencies, limiting searches to randomized phase 3 trials. Primary outcomes were stroke or systemic embolism (SSE) and major or non-major clinically relevant (NMCR) bleeding. We used a random-effects model to pool effect on outcomes according to different thresholds of cTTR. Four TTR sub-studies with a total of 71,222 patients were included. The benefit of NOAC in reducing SSE compared with warfarin was significantly higher in patients at cTTRwarfarin in patients at all sub-groups (0.67, 0.54-0.83 for patients at cTTRwarfarin for stroke prevention is lost above a cTTR threshold of approximately 70%, but the relative safety appears to be less modified by the centre-based quality of INR control. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Method of enhancing cyclotron beam intensity

    Science.gov (United States)

    Hudson, Ed D.; Mallory, Merrit L.

    1977-01-01

    When an easily ionized support gas such as xenon is added to the cold cathode in sources of the Oak Ridge Isochronous Cyclotron, large beam enhancements are produced. For example, .sup.20 Ne.sup.7+ is increased from 0.05 enA to 27 enA, and .sup.16 O.sup.5+ intensities in excess of 35 e.mu.A have been extracted for periods up to 30 minutes. Approximately 0.15 cc/min of the easily ionized support gas is supplied to the ion source through a separate gas feed line and the primary gas flow is reduced by about 30%.

  10. New compact cyclotron design for SPIRAL

    International Nuclear Information System (INIS)

    Duval, M.; Bourgarel, M.P.; Ripouteau, F.

    1995-01-01

    The SPIRAL project whose purpose is the production and the acceleration of radioactive nuclei is under realization at GANIL. The new facility uses a cyclotron as post accelerator taking place behind the present machine. The magnet structure is made of 4 independent return yokes and a common circular pole piece (3.5 m in diameter) with 4 sectors. The average induction needed is 1.56 Tesla with hill and valley gaps of respectively 0.12 and 0.3 m. The required field patterns are adjusted by means of circular trim coils located between the sectors and the pole piece. (author)

  11. Isotope separation by ionic cyclotron resonance

    International Nuclear Information System (INIS)

    Compant La Fontaine, A.; Gil, C.; Louvet, P.

    1986-10-01

    The principle of the process of isotopic separation by ionic cyclotron resonance is explained succinctly. The theoretical calculation of the isotopic effect is given as functions of the electric and magnetic fields in the frame of single particle approximation and of plasma collective theory. Then, the main parts of the demonstration device which is in operation at the CEA, are described here: the supraconducting magnetic field, the used diagnostics, the principle of the source and the collecting apparatus. Some experimental results are given for chromium. The application of the process to ponderal separation of metal isotopes, as chromium, nickel and molybdenum is discussed in view of production of medical, structural and irradiation isotopes

  12. Diffusion induced by cyclotron resonance heating

    International Nuclear Information System (INIS)

    Riyopoulos, S.; Tajima, T.; Hatori, T.; Pfirsch, D.

    1985-09-01

    The wave induced particle transport during the ion cyclotron resonance heating is studied in collisionless toroidal plasmas. It is shown that the previously neglected non-conservation of the toroidal angular momentum IP/sub phi/ caused by the toroidal wave component E/sub phi/ is necessary to allow particle diffusion and yields the leading diffusive contribution. While the induced ion transport for the rf power in contemporary experiments is of the order of the neoclassical value, that of fast alpha particles is quite large if resonance is present

  13. RELATIVISTIC CYCLOTRON INSTABILITY IN ANISOTROPIC PLASMAS

    Energy Technology Data Exchange (ETDEWEB)

    López, Rodrigo A.; Moya, Pablo S.; Muñoz, Víctor; Valdivia, J. Alejandro [Departamento de Física, Facultad de Ciencias, Universidad de Chile, Casilla 653, Santiago (Chile); Navarro, Roberto E.; Araneda, Jaime A. [Departamento de Física, Facultad de Ciencias Físicas y Matemáticas, Universidad de Concepción, Casilla 160-C, Concepción (Chile); Viñas, Adolfo F., E-mail: rlopez186@gmail.com [NASA Goddard Space Flight Center, Heliophysics Science Division, Geospace Physics Laboratory, Mail Code 673, Greenbelt, MD 20771 (United States)

    2016-11-20

    A sufficiently large temperature anisotropy can sometimes drive various types of electromagnetic plasma micro-instabilities, which can play an important role in the dynamics of relativistic pair plasmas in space, astrophysics, and laboratory environments. Here, we provide a detailed description of the cyclotron instability of parallel propagating electromagnetic waves in relativistic pair plasmas on the basis of a relativistic anisotropic distribution function. Using plasma kinetic theory and particle-in-cell simulations, we study the influence of the relativistic temperature and the temperature anisotropy on the collective and noncollective modes of these plasmas. Growth rates and dispersion curves from the linear theory show a good agreement with simulations results.

  14. Cyclotron resonance in a cathode ray tube

    International Nuclear Information System (INIS)

    Gherbanovschi, N.; Tanasa, M.; Stoican, O.

    2002-01-01

    Absorption of the RF energy by the electron beam in a cathode ray tube due to the cyclotron resonance is described. The cathode ray tube is placed within a Helmholtz coils system supplied by a sawtooth current generator. In order to generate RF field and to detect RF absorption a gate dip-meter equipped with a FET transistor is used. The bias voltage variations of the FET transistors as a function of the magnetic field are recorded. The operating point of the cathode ray tube has been chosen so that the relaxation oscillations of the detection system can be observed. (authors)

  15. Properties of the TRIUMF cyclotron beam

    International Nuclear Information System (INIS)

    Craddock, M.K.; Blackmore, E.W.; Dutto, G.; Kost, C.J.; Mackenzie, G.H.; Richardson, J.R.; Root, L.W.; Schmor, P.

    1975-08-01

    Eight percent of the 300 keV d.c. beam from the ion source can be transmitted to 500 MeV in the TRIUMF cyclotron, without using the buncher. The beam losses are entirely accounted for; there are no significant losses due to orbit dynamic problems during 1500 turns of acceleration. The phase history is in good agreement with predictions based on the magnetic field survey. The effect of the harmonic coils and injection parameters on beam quality has been investigated. (author)

  16. High efficiency cyclotron trap assisted positron moderator

    OpenAIRE

    Gerchow, L.; Cooke, D. A.; Braccini, S.; Döbeli, M.; Kirch, K.; Köster, U.; Müller, A.; Van Der Meulen, N. P.; Vermeulen, C.; Rubbia, A.; Crivelli, P.

    2017-01-01

    We report the realisation of a cyclotron trap assisted positron tungsten moderator for the conversion of positrons with a broad keV- few MeV energy spectrum to a mono-energetic eV beam with an efficiency of 1.8(2)% defined as the ratio of the slow positrons divided by the $\\beta^+$ activity of the radioactive source. This is an improvement of almost two orders of magnitude compared to the state of the art of tungsten moderators. The simulation validated with this measurement suggests that usi...

  17. Axial injection in Orsay superconducting cyclotron

    International Nuclear Information System (INIS)

    Depauw, J.; Kugler, M.F.; Legoff, A.; Potier, J.C.; Richomme, A.; Skowron, R.; Mandrillon, P.; Schapira, J.P.

    1983-01-01

    The compact superconducting cyclotron currently planned at IPN at Orsay is designed for light ion acceleration together with heavy ion acceleration. From the beginning, for this reason, a central geometry able to receive an inflector (to 90deg C) allowing the axial injection of low energy ion beams given by an outer source. The present study is aimed at showing the technical feasibility of theoretical results obtained on axial injection. First experimental study has been made of spatial repartition in three dimensions of electric potential developed by a central geometry of 3 electrodes. Then, the electric study of an electrostatic mirror has been made [fr

  18. Cyclotrons at the Institute of Physical and Chemical Research

    International Nuclear Information System (INIS)

    Imamura, Masashi.

    1989-01-01

    In this article the destruction by American forces, during World War II, of the Japanese cyclotrons and the subsequent construction of new cyclotrons at the Institute of Physical and Chemical Research, Japan is described. Their use for biological and medical radiation chemistry studies is summarized. (UK)

  19. Lower-hybrid absorption at the ion cyclotron harmonics

    International Nuclear Information System (INIS)

    Puri, S.

    1975-01-01

    In the presence of magnetic field gradients, the lower-hybrid wave can be absorbed through linear collisionless damping at the location of cyclotron or cyclotron harmonic resonances acting as singular turning points in the path of the advancing wave-front. (Auth.)

  20. A radioisotope production cyclotron designed to minimize dose

    International Nuclear Information System (INIS)

    Szlavik, F.F.; Moritz, L.E.

    1992-01-01

    This paper describes a radioisotope production cyclotron which has been designed to minimize the dose to personnel during operation and maintenance. The design incorporates lessons learned from the operation of a CP42 cyclotron and has resulted in a reduction of the dose by a factor of more than 10. (author)

  1. Calculation of particle dynamics in CI-10 cyclotron

    International Nuclear Information System (INIS)

    Samsonov, E.V.; Karamysheva, G.A.; Vorozhtsov, S.B.

    1999-01-01

    The calculations of beam dynamic characteristics of High-Intensity Cyclotron-Injector CI-10 for deuteron beam of 15 MeV energy are presented. Analytical estimations of space charge effects are given. In order to increase the intensity of the accelerator beam some ideas about the cyclotron design modification are given too. (author)

  2. First results of beam generation test for JAERI AVF cyclotron

    International Nuclear Information System (INIS)

    Tachikawa, T.; Hayashi, Y.; Ishii, K.

    1992-01-01

    The performance of JAERI AVF cyclotron was investigated with several kinds of ions in the wide energy range. The 90 MeV protons of 10 μA intensity was successfully extracted for the first time by the model 930 cyclotron. The feature of beam chopping system is also presented. (author)

  3. Resonance cones below the ion cyclotron frequency: theory and experiment

    International Nuclear Information System (INIS)

    Bellan, P.

    1976-03-01

    The resonance cones existing below the ion cyclotron frequency, ω/sub c/sub i//, are shown, theoretically and experimentally, to be the asymptotes of hyperbolic constant-phase surfaces of low-frequency ion acoustic waves. Above ω/sub c/sub i// the surfaces transform into ellipses that are related to the electrostatic ion cyclotron waves and ion acoustic waves

  4. Computer modeling of magnetic structure for IC-35 cyclotron

    International Nuclear Information System (INIS)

    Alenitskij, Yu.G.; Morozov, N.A.

    1998-01-01

    An extensive series of calculations has been carried out in order to design the magnetic structure of the IC-35 cyclotron for radioisotope production. The calculations were carried out by 2-D POISCR code. The average magnetic field and its variation were produced with the help of two different calculation models. The parameters of the cyclotron magnetic system are presented

  5. Fabrication of beam diagnostic components for Superconducting Cyclotron at Kolkata

    International Nuclear Information System (INIS)

    Roy, S.; Bhattacharya, S.; Das, T.; Bhattacharyya, T.K.; Pal, S.; Pal, G.; Mallik, C.; Bhandari, R.K.

    2009-01-01

    The viewer probe and main probe are used for determining the position and current of charged particles as it is accelerated inside the superconducting cyclotron. The viewer probe is used to visually observe the shape of the charged particle beam inside the cyclotron with the help of a borescope. The main probe measures the distribution of charged particles. The viewer probe and main probe are bellow sealed. They can be positioned with an accuracy of 0.5 mm at different radii within the superconducting cyclotron. M9 slit is placed after the exit flange of the cyclotron. It determines the position of the beam leaving the cyclotron. The beam line has slits, faraday cup, beam viewers, collimators, etc. for beam diagnostics. This paper presents the mechanical design and details of beam diagnostic components. (author)

  6. New superconducting cyclotron driven scanning proton therapy systems

    International Nuclear Information System (INIS)

    Klein, Hans-Udo; Baumgarten, Christian; Geisler, Andreas; Heese, Juergen; Hobl, Achim; Krischel, Detlef; Schillo, Michael; Schmidt, Stefan; Timmer, Jan

    2005-01-01

    Since one and a half decades ACCEL is investing in development and engineering of state of the art particle-therapy systems. A new medical superconducting 250 MeV proton cyclotron with special focus on the present and future beam requirements of fast scanning treatment systems has been designed. The first new ACCEL medical proton cyclotron is under commissioning at PSI for their PROSCAN proton therapy facility having undergone successful factory tests especially of the closed loop cryomagnetic system. The second cyclotron is part of ACCEL's integrated proton therapy system for Europe's first clinical center, RPTC in Munich. The cyclotron, the energy selection system, the beamline as well as the four gantries and patient positioners have been installed. The scanning system and major parts of the control software have already been tested. We will report on the concept of ACCEL's superconducting cyclotron driven scanning proton therapy systems and the current status of the commissioning work at PSI and RPTC

  7. Operation of the Karlsruhe Isochronous Cyclotron in 1975

    International Nuclear Information System (INIS)

    Schulz, F.; Schweickert, H.

    1976-06-01

    The operation of the Karlsruhe Isochronous Cyclotron in 1975 is briefly surveyed. The main reasons for a very short period for maintenance, repair and installation, and several additional efforts to improve the reliability of the accelerator installation, are discussed. The status and the results of several technical developments for the cyclotron are described: 1) the axial injection system; 2) computer aided cyclotron operation; 3) ion source development; 4) capacitive current measurement at the external beam; 5) new correction coils for the cyclotron; 6) improvement of the neutron time-of-flight spectrometer. As there is an increasing interest in using this type of accelerator for research in fields other than nuclear physics, it was felt appropriate to present short surveys on investigations at our cyclotron in 1975 in the fields of: 1) solid state physics; 2) engineering; 3) materials research; 4) nuclear medicine; 5) nuclear chemistry. (orig.) [de

  8. A new generation of medical cyclotrons for the 90's

    International Nuclear Information System (INIS)

    Milton, B.F.

    1995-08-01

    Cyclotrons continue to be efficient accelerators for use in radio-isotope production. In recent years, developments in accelerator technology have greatly increased the practical beam current in these machines while also improving the overall system reliability. These developments combined with the development of new isotopes for medicine and industry, and a retiring of older machines indicates a strong future for commercial cyclotrons. In this paper the authors will survey recent developments in the areas of cyclotron technology as they relate to the new generation of commercial cyclotrons. Existing and potential markets for these cyclotrons will be presented. They will also discuss the possibility of systems capable of extracted energies up to 150 MeV and extracted beam currents of up to 2.0 mA

  9. A new generation of medical cyclotrons for the 90's

    International Nuclear Information System (INIS)

    Milton, B.F.

    1995-08-01

    Cyclotrons continue to be efficient accelerators for use in radio-isotope production. In recent years, developments in accelerator technology have greatly increased the practical beam current in these machines while also improving the overall system reliability. These developments combined with the development of new isotopes for medicine and industry, and a retiring of older machines indicates a strong future for commercial cyclotrons. In this paper we will survey recent developments in the areas of cyclotron technology as they relate to the new generation of commercial cyclotrons. Existing and potential markets for these cyclotrons will be presented. We will also discuss the possibility of systems capable of extracted energies up to 150 MeV and extracted beam currents of up to 2.0 mA. (author)

  10. U-2g0 cyclotron operational experience and improvement

    International Nuclear Information System (INIS)

    Gigal, B.N.; Gul'bekyan, G.G.; Kozlov, S.I.; Oganesyan, R.Ts.

    1983-01-01

    Brief description of main syste's of the U-200 isochronous 2-m cyclotron put into opera ion in 1968 is given and its operational characteristics a e presented. The cyclotron is used for conducting inve tigations in the field of nuclear physics. Ions from d uterium to argon have been accelerated in the cyclotro'. Annual time of target irradiation constitutes 2000-4000. The specific features of the cyclotron are: high l vel of a magnetic field (of about 20 kOe), possibili y of acceleration of ions with different mass-to-charge ratio a low correcting winding power, simple and high-e fective beam extraction by the method of charge exchange on a thin target allowing to vary smoothly energy of extracted ons. An experience in the U-200 cyclotron development and o eration is used as the basis for designing and choosing basic parameters of the U-200P, U-250, U-400 heavy ion cyclotrons

  11. Status report on RIKEN Ring Cyclotron

    International Nuclear Information System (INIS)

    Yano, Y.

    1988-01-01

    This paper gives a status report on RIKEN Ring Cyclotron (RRC), successfully commissioned on December 16, 1986. The routine operation of RRC began in April, 1987, and was made until March 1988. April and May were devoted to the machine studies, and beams were delivered to the experiments from the end of May. Seven kinds of ion species from carbon to copper were used for the nuclear physics and atomic physics experiments during these one-year runs. High quality beams with transverse emittances less than 10 mm mrad, energy spread of approximately 0.1% and pulse width less than 300 psec were extracted. Since the middle of March, 1988, RRC has been shut down for extending the beam transfer lines and installing the various experimental setups. Next experimental program will start in July, 1988. The initial operational status of RRC is described as well as the running construction program of the new injector, a K70 AVF cyclotron with an external ECR ion source

  12. Electron cyclotron heating calculations for ATF

    International Nuclear Information System (INIS)

    Goldfinger, R.C.; Batchelor, D.B.

    1986-03-01

    The RAYS geometrical optics code has been used to calculate electron cyclotron wave propagation and heating in the Advanced Toroidal Facility (ATF) device under construction at Oak Ridge National Laboratory (ORNL). The intent of this work is to predict the outcome of various heating scenarios and to give guidance in designing an optimum heating system. Particular attention is paid to the effects of wave polarization and antenna location. We investigate first and second harmonic cyclotron heating with the parameters predicted for steady-state ATF operation. We also simulate the effect of wall reflections by calculating a uniform, isotropic flux of power radiating from the wall. These results, combined with the first-pass calculations, give a qualitative picture of the heat deposition profiles. From these results we identify the compromises that represent the optimum heating strategies for the ATF model considered here. Our basic conclusions are that second harmonic heating with the extraordinary mode (X-mode) gives the best result, with fundamental ordinary mode (O-mode) heating being slightly less efficient. Assuming the antenna location is restricted to the low magnetic field side, the antenna should be placed at phi = 0 0 (the toroidal angle where the helical coils are at the sides) for fundamental heating and at phi = 15 0 (where the helical coils are at the top and bottom) for second harmonic heating. These recommendations come directly from the ray tracing results as well as from a theoretical identification of the relevant factors affecting the heating

  13. Acceleration of tritons with a compact cyclotron

    International Nuclear Information System (INIS)

    Wegmann, H.; Huenges, E.; Muthig, H.; Moringa, H.

    1981-01-01

    With the compact cyclotron at the Faculty of Physics of the Technical University of Munich, tritons have been accelerated to an energy of 7 MeV. A safe and reliable operation of the gas supply for the ion source was obtained by a new tritium storage system. A quantity of 1500 Ci tritium is stored by two special Zr-Al getter pumps in a non-gaseous phase. The tritium can be released in well-defined amounts by heating the getter material. During triton acceleration the pressure in the cyclotron vacuum chamber is maintained only by a large titanium sputter-ion pump, thus forming a closed vacuum system without any exhaust of tritium contaminated gas. Any tritium contaminations in the air can be detected by an extremely sensitive tritium monitoring system. The triton beam with a maximum intensity of 30 μA has been used so far to produce neutron-rich radioisotopes such as 28 Mg, 43 K, or 72 Zn, which are successfully applied in tracer techniques in the studies of biological systems. (orig.)

  14. Cyclotron Resonances in Electron Cloud Dynamics

    International Nuclear Information System (INIS)

    Celata, C.M.; Furman, M.A.; Vay, J.L.; Grote, D.P.; Ng, J.T.; Pivi, M.F.; Wang, L.F.

    2009-01-01

    A new set of resonances for electron cloud dynamics in the presence of a magnetic field has been found. For short beam bunch lengths and low magnetic fields where l b c , (l b = bunch duration, ω c = non-relativistic cyclotron frequency) resonances between the bunch frequency and harmonics of the cyclotron frequency cause an increase in the electron cloud density in narrow ranges of magnetic field near the resonances. For ILC parameters the increase in the density is up to a factor ∼ 3, and the spatial distribution of the electrons is broader near resonances, lacking the well-defined density 'stripes' of multipactoring found for non-resonant cases. Simulations with the 2D computer code POSINST, as well as a single-particle tracking code, were used to elucidate the physics of the dynamics. The resonances are expected to affect the electron cloud dynamics in the fringe fields of conventional lattice magnets and in wigglers, where the magnetic fields are low. Results of the simulations, the reason for the bunch-length dependence, and details of the dynamics will be discussed

  15. Visual assistance system for cyclotron operation

    International Nuclear Information System (INIS)

    Okamura, Tetsuya; Tachikawa, Toshiki; Murakami, Tohru.

    1994-01-01

    A computer-based operation system for a cyclotron which assists operators has been developed. It is the operation assistance system depending on visual sense to indicate beam parameters to operators. First, the mental model of operators at the time of beam adjustment was analyzed, and it was presumed to be composed of five partial mental models, that is, beam behavior model, feasible setting region model, parameter sensitivity model, parameter interrelation model and status map model. Next, three visual interfaces were developed. Beam trajectory is rapidly calculated and graphically displayed whenever operators change parameters. Feasible setting regions (FSR) for parameters that satisfy the beam acceptance criteria of a cyclotron are indicated. The distribution of beam current values which are the quantity for evaluating adjustment is indicated as search history. Finally, for evaluating the system effectiveness, the search time required to reach the optimum conditions was measured. In addition, the system usability was evaluated by written questionnaires. The result of experiment showed the reduction of search time by about 65%. The written questionnaires survey showed the operators highly evaluate system usability. (K.I.)

  16. POCT PT INR - Is it adequate for patient care? A comparison of the Roche Coaguchek XS vs. Stago Star vs. Siemens BCS in patients routinely seen in an anticoagulation clinic.

    Science.gov (United States)

    Baker, Wendy S; Albright, Kathleen J; Berman, Megan; Spratt, Heidi; Mann, Peggy A; Unabia, Jaime; Petersen, John R

    2017-09-01

    In this study we examined the difference in patient INR values as measured by the POCT CoaguChek XS device and central laboratory Stago Evolution and Siemens BCS XP analyzers. This study composed of 100 warfarin therapy patients and 20 coagulation normal subjects, showed that the difference between the POCT and clinical laboratory values increased with increasing INR and was exacerbated by the use of different thromboplastin reagents by the POCT and central lab. The CoaguChek XS and on-site Stago analyzers which used human recombinant (ISI=1.01) and rabbit brain thromboplastin (ISI=1.25), respectively, showed reasonable agreement for INR5.0 with the Stago Evolution prevented adverse treatment events for the warfarin therapy patients in the six months preceding and following this investigation. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Cyclotron Production of Technetium-99m

    Science.gov (United States)

    Gagnon, Katherine M.

    Technetium-99m (99mTc) has emerged as the most widely used radionuclide in medicine and is currently obtained from a 99Mo/ 99mTc generator system. At present, there are only a handful of ageing reactors worldwide capable of producing large quantities of the parent isotope, 99Mo, and owing to the ever growing shutdown periods for maintenance and repair of these ageing reactors, the reliable supply 99mTc has been compromised in recent years. With an interest in alternative strategies for producing this key medical isotope, this thesis focuses on several technical challenges related to the direct cyclotron production of 99mTc via the 100Mo(p,2n)99mTc reaction. In addition to evaluating the 100Mo(p,2n)99mTc and 100Mo(p,x)99Mo reactions, this work presented the first experimental evaluation of the 100Mo(p,2n) 99gTc excitation function in the range of 8-18 MeV. Thick target calculations suggested that large quantities of cyclotron-produced 99mTc may be possible. For example, a 6 hr irradiation at 500 μA with an energy window of 18→10 MeV is expected to yield 1.15 TBq of 99mTc. The level of coproduced 99gTc contaminant was found to be on par with the current 99Mo/99mTc generator standard eluted with a 24 hr frequency. Highly enriched 100Mo was required as the target material for 99mTc production and a process for recycling of this expensive material is presented. An 87% recovery yield is reported, including metallic target preparation, irradiation, 99mTc extraction, molybdate isolation, and finally hydrogen reduction to the metal. Further improvements are expected with additional optimization experiments. A method for forming structurally stable metallic molybdenum targets has also been developed. These targets are capable of withstanding more than a kilowatt of beam power and the reliable production and extraction of Curie quantities of 99mTc has been demonstrated. With the end-goal of using the cyclotron-produced 99mTc clinically, the quality of the cyclotron

  18. Electromagnetic ion cyclotron waves observed near the oxygen cyclotron frequency by ISEE 1 and 2

    Science.gov (United States)

    Fraser, B. J.; Samson, J. C.; Hu, Y. D.; Mcpherron, R. L.; Russell, C. T.

    1992-01-01

    The first results of observations of ion cyclotron waves by the elliptically orbiting ISEE 1 and 2 pair of spacecraft are reported. The most intense waves (8 nT) were observed in the outer plasmasphere where convection drift velocities were largest and the Alfven velocity was a minimum. Wave polarization is predominantly left-handed with propagation almost parallel to the ambient magnetic field, and the spectral slot and polarization reversal predicted by cold plasma propagation theory are identified in the wave data. Computations of the experimental wave spectra during the passage through the plasmapause show that the spectral slots relate to the local plasma parameters, possibly suggesting an ion cyclotron wave growth source near the spacecraft. A regular wave packet structure seen over the first 30 min of the event is attributed to the modulation of this energy source by the Pc 5 waves seen at the same time.

  19. Compact superconducting cyclotron C400 for hadron therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jongen, Y.; Abs, M.; Blondin, A.; Kleeven, W.; Zaremba, S.; Vandeplassche, D. [IBA, Chemin du Cyclotron 3, B-1348 Louvain-la-Neuve (Belgium); Aleksandrov, V.; Gursky, S.; Karamyshev, O. [JINR, Joliot-Curie 6, 141980 Dubna, Moscow region (Russian Federation); Karamysheva, G., E-mail: gkaram@nu.jinr.r [JINR, Joliot-Curie 6, 141980 Dubna, Moscow region (Russian Federation); Kazarinov, N.; Kostromin, S.; Morozov, N.; Samsonov, E.; Shirkov, G.; Shevtsov, V.; Syresin, E.; Tuzikov, A. [JINR, Joliot-Curie 6, 141980 Dubna, Moscow region (Russian Federation)

    2010-12-01

    The compact superconducting isochronous cyclotron C400 has been designed by the IBA-JINR collaboration. It will be the first cyclotron in the world capable of delivering protons, carbon and helium ions for cancer treatment. The cyclotron construction is started this year within the framework of the Archade project (Caen, France). {sup 12}C{sup 6+} and {sup 4}He{sup 2+} ions will be accelerated to 400 MeV/uu energy and extracted by the electrostatic deflector, H{sub 2}{sup +} ions will be accelerated to the energy of 265 MeV/uu and extracted by stripping. The magnet yoke has a diameter of 6.6 m, the total weight of the magnet is about 700 t. The designed magnetic field corresponds to 4.5 T in the hills and 2.45 T in the valleys. Superconducting coils will be enclosed in a cryostat; all other parts of the cyclotron will be warm. Three external ion sources will be mounted on the switching magnet on the injection line located below the cyclotron. The main parameters of the cyclotron, its design, the current status of the development work on the cyclotron systems are presented.

  20. Cyclotron Development and Technical Aspects on Accelerator Based Laboratory Development

    International Nuclear Information System (INIS)

    Sunarhadijoso

    2000-01-01

    BATAN is planning to establish an accelerator-based laboratory at P3TM Yogyakarta as an effort in the development and use of accelerator technology for improving industrial performance and public welfare. This paper reviews several aspects of cyclotron technology and describes the combination of a linear accelerator - cyclotron system as an alternative to be considered in the planing of the laboratory. The progress of cyclotron technology is discussed covering three generations, i.e. conventional cyclotron, synchrocyclotron and AVF cyclotron generations. The planning should not consider the accelerator application for radioisotope production because it is established in Serpong with the existing negative ion cyclotron. The proposed facility at P3TM may comprise two linear accelerators coupled with a positive ion cyclotron of synchrocyclotron generation. In fact, the attachment of the synchrocyclotron unit is flexible and it can be installed subsequently if the higher energy particle beam, which can not be produced by the linear accelerators, is extremely needed. Some technical aspects related to ion beam application, building construction and infrastructure, human resources, and specification of function test are discussed for additional information in the implementation of the planning. (author)

  1. Survey on radionuclide producing using cyclotron method in Malaysia

    International Nuclear Information System (INIS)

    Mohd Fadli Mohammad Noh

    2008-01-01

    This research discuss about basic design and systems of medical cyclotron that Malaysia currently have, its applications in radionuclide production and upcoming technologies of cyclotron. Surveys have been carried out on cyclotron facilities at Hospital Putrajaya and Wijaya International Medical Center, WIMC as well as reactor facility at Malaysia Nuclear Agency. The sources in this research also involves on-line and library searches. Information obtained are recorded, categorized, synthesized and discussed. systems of cyclotron of Hospital Putrajaya are further discussed in details. Based from the surveys carried out, it is found out that cyclotron facilities both in Hospital Putrajaya and WIMC only produce ( 18 F)FDG with radioactivity of 18 F produced in 2007 are 16479 mCi and 92546 mCi respectively. Survey also revealed that radioisotope production at Nuclear Malaysia has had its operation been ceased. A new radiopharmaceutical, namely CHOL is suggested to be synthesized by both facilities as a new PET tracer. Latest developments concerning technologies of cyclotron as well as other accelerators such as laser for future medical accelerator, prospect of boron neutron capture and the potential of hadron therapy in Malaysia are discussed here. Radioisotope production in Malaysia is expected to keep booming in future due to increase in usage of PET techniques and the construction of more compact, easy to handle and less costly cyclotrons. (author)

  2. Electromagnetic ion cyclotron waves observed near the oxygen cyclotron frequency by ISEE 1 and 2

    International Nuclear Information System (INIS)

    Fraser, B.J.; Samson, J.C.; Hu, Y.D.; McPherron, R.L.; Russell, C.T.

    1992-01-01

    Pc 2 electromagnetic ion cyclotron waves at 0.1 waves at 0.1 Hz, near the oxygen cyclotron frequency, have been observed by ISEE 1 and 2 between L = 7.6 and 5.8 on an inbound near-equatorial pass in the dusk sector. The waves occurred in a thick plasmapause of width ∼ 1.5 R E and penetrated ∼1 R E into the plasmasphere. Wave onset was accompanied by significant increases in the thermal (0-100 eV) He + and the warm (0.1-16 keV/e) O + and He + heavy ion populations. The most intense waves (8 nT) were observed in the outer plasmasphere where convection drift velocities (E x B)/B 2 were largest and the Alfven velocity was a minimum. Wave polarization is predominantly left-handed with propagation almost parallel to the ambient magnetic field, and the spectral slot and polarization reversal predicted by cold plasma propagation theory are identified in the wave data. Poynting fluxes calculated during the first 15 min of the event show wave energy propagation directions both parallel and antiparallel to the field. Computations of the experimental wave spectra during the passage through the plasmapause show that the spectral slots relate to local plasma parameters, possibly suggesting an ion cyclotron wave growth source near the spacecraft. A regular wave packet structure seen over the first 30 min of the event may be attributed to the modulation of this energy source by the Pc 5 waves seen at the same time. Overall, the results are considered an example of an electromagnetic ion cyclotron wave-particle interaction occurring during the outer plasmasphere refilling process at the time of the substorm recovery phase

  3. Present status of device controls and hardware interfaces for the RCNP ring cyclotron

    International Nuclear Information System (INIS)

    Yamazaki, T.; Tamura, K.; Hosono, K.

    1994-01-01

    Since the first proton beam from the injector AVF cyclotron was injected to the ring cyclotron in 1991, the computer control system has been used for the beam acceleration of the ring cyclotron. Some device control modules have been updated, and computer configuration has been changed in 1992. Total control system performs basic facilities almost satisfactory under actual cyclotron operation. (author)

  4. Electromagnetic Ion Cyclotron Waves in the Helium Branch Induced by Multiple Electromagnetic Ion Cyclotron Triggered Emissions

    Science.gov (United States)

    Shoji, M.; Omura, Y.; Grison, B.; Pickett, J. S.; Dandouras, I. S.; Engebretson, M. J.

    2011-12-01

    Electromagnetic ion cyclotron (EMIC) triggered emissions with rising tones between the H+ and He+ cyclotron frequencies were found in the inner magnetosphere by the recent Cluster observations. Another type of EMIC wave with a constant frequency is occasionally observed below the He+ cyclotron frequency after the multiple EMIC triggered emissions. We performed a self-consistent hybrid simulation with a one-dimensional cylindrical magnetic flux model approximating the dipole magnetic field of the Earth's inner magnetosphere. In the presence of energetic protons with a sufficient density and temperature anisotropy, multiple EMIC triggered emissions are reproduced due to the nonlinear wave growth mechanism of rising-tone chorus emissions, and a constant frequency wave in the He+ EMIC branch is subsequently generated. Through interaction with the multiple EMIC rising-tone emissions, the velocity distribution function of the energetic protons is strongly modified. Because of the pitch angle scattering of the protons, the gradient of the distribution in velocity phase space is enhanced along the diffusion curve of the He+ branch wave, resulting in the linear growth of the EMIC wave in the He+ branch.

  5. Analytic descriptions of ion cyclotron absorption

    International Nuclear Information System (INIS)

    Bers, A.; Francis, G.; Fuchs, V.; Lashmore-Davies, C.N.; Ram, A.K.

    1987-05-01

    Analysis of energy propagation and absorption in ion-cyclotron heating of tokamak plasmas has relied on numerical solutions of fourth (and sixth) order differential equations for slab models of the plasma (poloidal) cross section. Realistic two-dimensional and fully toroidal geometry analyses would become quite unwieldy. It is shown here that the analysis of the slab model can be simplified considerably. A first-order differential equation is shown to describe the transmission coefficient for the fast wave, and it is solved analytically. A second order differential equation is shown to adequately describe both transmission and reflection. Conditions for ion absorption or mode conversion are derived. Including toroidal effects in propagation, conditions for electron absorption on the mode-converted ion-Bernstein waves are also described analytically

  6. Ion cyclotron emission by spontaneous emission

    Energy Technology Data Exchange (ETDEWEB)

    Da Costa, O [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Gresillon, D [Ecole Polytechnique, 91 - Palaiseau (France). Lab. de Physique des Milieux Ionises

    1994-07-01

    The goal of the study is to examine whether the spontaneous emission can account for ICE (ion cyclotron emission) experimental results, or part of them. A straightforward approach to plasma emission is chosen, investigating the near equilibrium wave radiation by gyrating ions, and thus building from the majority and fast fusion ions the plasma fluctuations and emission on the fast magnetoacoustic or compressional Alfven wave mode in the IC frequency range. Similarities with the ICE experiments are shown: the emission temperature in the presence of fast ions (even in a very small amount), the strong fast ion emission increase with the harmonic, the fine double-line splitting of each peak, the linear but not proportional increase of the peak width with the harmonic. 3 refs., 2 figs.

  7. In-house cyclotron and nuclear medicine

    International Nuclear Information System (INIS)

    Tateno, Yukio; Shishido, Fumio; Yamazaki, Toshiro

    1982-01-01

    In-house cyclotron produced radioisotopes and positron computed tomography provide a unique technique which gives cross-sectional bodyimages of various kinds of physiological activities of living human body. Applications of the technique to clinical study might throw a new light on the etiologically unknown disorders of human central nervous system and etc. However, some difficulties should be settled before the establishment of this technique as an useful research and diagnostic tool. One of them was spatial resolution of positron computed tomography, and another was selection and development of really effective labeled compounds for the disease in question. A rotary positron emission computed tomography device was developed by our physicist team, and our chemist team developed various kinds of radiopharmaceuticals. Clinical applications of the technique started in our institute in November 1979, using the positron computed tomography machine named Positrologica I and the pharmaceuticals, 13sup( n h3, )11sup( C o and )18 F-2-fluoro-deoxy-glucose. (author)

  8. Electron cyclotron resonance heating and current drive

    Energy Technology Data Exchange (ETDEWEB)

    Fidone, I.; Castejon, F.

    1992-07-01

    A brief summary of the theory and experiments on electron- cyclotron heating and current drive is presented. The general relativistic formulation of wave propagation and linear absorption is considered in some detail. The O-mode and the X-mode for normal and oblique propagation are investigated and illustrated by several examples. The experimental verification of the theory in T-10 and D- III-D is briefly discussed. Quasilinear evolution of the momentum distribution and related applications as, for instance, non linear wave, damping and current drive, are also considered for special cases of wave frequencies, polarization and propagation. In the concluding section we present the general formulation of the wave damping and current drive in the absence of electron trapping for arbitrary values of the wave frequency. (Author) 13 refs.

  9. Electron cyclotron resonance (ECR) ion sources

    International Nuclear Information System (INIS)

    Jongen, Y.

    1984-05-01

    Starting with the pioneering work of R. Geller and his group in Grenoble (France), at least 14 ECR sources have been built and tested during the last five years. Most of those sources have been extremely successful, providing intense, stable and reliable beams of highly charged ions for cyclotron injection or atomic physics research. However, some of the operational features of those sources disagreed with commonly accepted theories on ECR source operation. To explain the observed behavior of actual sources, it was found necessary to refine some of the crude ideas we had about ECR sources. Some of those new propositions are explained, and used to make some extrapolations on the possible future developments in ECR sources

  10. Particle acceleration by electromagnetic ion cyclotron turbulence

    International Nuclear Information System (INIS)

    Crew, G.B.; Chang, Tom

    1990-01-01

    The LF EM-turbulence which furnishes energy for the acceleration of ions in various regions of the earth's magnetosphere efficiently accomplishes its transfer of energy from waves to particles through ion cyclotron resonance (ICR) with the left-hand polarized component of the turbulence; the result of this interaction is a heating of the particle distribution. A general theoretical treatment of ICR heating in a weakly inhomogeneous magnetic geometry is presented, en route to a more detailed examination of auroral ion conics' formation. A substantial simplification of the analysis of the altitude-asymptotic form of the conic distribution is obtained via the similarity transformation introduced into the properties of the electric field spectral density and the earth's dipolar magnetic field. 60 refs

  11. Ion cyclotron emission by spontaneous emission

    International Nuclear Information System (INIS)

    Da Costa, O.; Gresillon, D.

    1994-01-01

    The goal of the study is to examine whether the spontaneous emission can account for ICE (ion cyclotron emission) experimental results, or part of them. A straightforward approach to plasma emission is chosen, investigating the near equilibrium wave radiation by gyrating ions, and thus building from the majority and fast fusion ions the plasma fluctuations and emission on the fast magnetoacoustic or compressional Alfven wave mode in the IC frequency range. Similarities with the ICE experiments are shown: the emission temperature in the presence of fast ions (even in a very small amount), the strong fast ion emission increase with the harmonic, the fine double-line splitting of each peak, the linear but not proportional increase of the peak width with the harmonic. 3 refs., 2 figs

  12. Ion cyclotron heating in TMX-U

    International Nuclear Information System (INIS)

    Dimonte, G.; Barter, J.; Romesser, T.; Molvik, A.W.; Cummins, W.F.; Falabella, S.; Poulsen, P.

    1987-01-01

    Ion cyclotron heating (ICH) is applied to TMX-U to improve the thermal barrier performance by reducing the passing ion collisionality. During its development, measurements of the antenna loading resistance, R p , and the absorption efficiency, η, were compared with calculations with the antenna design code ANTENA over a wide range of densities and frequencies. Good agreement in R p was obtained in the short wavelength slow wave regime but not for long wavelength fast waves because the experimental magnetic field gradients are not modelled in ANTENA. Similarly, η is much larger experimentally (40%) than in ANTENA (10%) due to the magnetic beach in TMX-U. In its application, ICH successfully decreased the passing ion collisionality tenfold but did not extend thermal barrier plugging to higher density, indicating that collisional barrier filling is not currently limiting TMX-U performance. (author). 23 refs, 23 figs

  13. Neutron radiography using a transportable superconducting cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Allen, D.A. (School of Physics and Space Research, University of Birmingham, Birmingham, B15 2TT (United Kingdom)); Hawkesworth, M.R. (School of Physics and Space Research, University of Birmingham, Birmingham, B15 2TT (United Kingdom)); Beynon, T.D. (School of Physics and Space Research, University of Birmingham, Birmingham, B15 2TT (United Kingdom)); Green, S. (School of Physics and Space Research, University of Birmingham, Birmingham, B15 2TT (United Kingdom)); Rogers, J.D. (Rolls-Royce, Derby (United Kingdom)); Allen, M.J. (Rolls-Royce, Derby (United Kingdom)); Plummer, H.C. (Rolls-Royce, MatEval, Derby (United Kingdom)); Boulding, N.J. (Oxford Instruments (United Kingdom)); Cox, M. (Oxford Instruments (United Kingdom)); McDougall, I. (Oxford Instruments (United Kingdom))

    1994-12-30

    A thermal neutron radiography system based on a compact 12 MeV superconducting proton cyclotron is described. Neutrons are generated using a thick beryllium target and moderated in high density polyethylene. Monte Carlo computer simulations have been used to model the neutron and photon transport in order to optimise the performance of the system. With proton beam currents in excess of 100 [mu]A, it can provide high thermal neutron fluxes with L/D ratios of between 50 and 300 for various applications. Both film and electronic imaging are used to produce radiographs. The electronic imaging system consists of a [sup 6]Li-loaded ZnS intensifier screen, and a low light CCD or SIT camera. High resolution images can be recorded and computer-controlled data processing, analysis and display are possible. ((orig.))

  14. Electron - cyclotron resonance heating and current drive

    International Nuclear Information System (INIS)

    Fidone, I.; Castejon, F.

    1992-01-01

    A brief summary of the theory and experiments on electron- cyclotron heating and current drive is presented. The general relativistic formulation of wave propagation and linear absorption is considered in some detail. The O-mode and the X-mode for normal and oblique propagation are investigated and illustrated by several examples. The experimental verification of the theory in T-10 and D- III-D is briefly discussed. Quasilinear evolution of the momentum distribution and related applications as, for instance, non linear wave, damping and current drive, are also considered for special cases of wave frequencies, polarization and propagation. In the concluding section we present the general formulation of the wave damping and current drive in the absence of electron trapping for arbitrary values of the wave frequency. (Author) 13 refs

  15. Electron Cyclotron Resonances in Electron Cloud Dynamics

    International Nuclear Information System (INIS)

    Celata, Christine; Celata, C.M.; Furman, Miguel A.; Vay, J.-L.; Yu, Jennifer W.

    2008-01-01

    We report a previously unknown resonance for electron cloud dynamics. The 2D simulation code 'POSINST' was used to study the electron cloud buildup at different z positions in the International Linear Collider positron damping ring wiggler. An electron equilibrium density enhancement of up to a factor of 3 was found at magnetic field values for which the bunch frequency is an integral multiple of the electron cyclotron frequency. At low magnetic fields the effects of the resonance are prominent, but when B exceeds ∼(2 pi mec/(elb)), with lb = bunch length, effects of the resonance disappear. Thus short bunches and low B fields are required for observing the effect. The reason for the B field dependence, an explanation of the dynamics, and the results of the 2D simulations and of a single-particle tracking code used to elucidate details of the dynamics are discussed

  16. Auxiliary accelerating system for TRIUMF cyclotron

    International Nuclear Information System (INIS)

    Zach, M.; Fong, K.; Laxdal, R.; Mackenzie, G.H.; Pacak, V.; Pearson, J.; Richardson, J.R.; Stanford, G.; Worsham, R.

    1990-06-01

    A 92 MHz auxiliary accelerating cavity has been designed and manufactured for installation in the TRIUMF cyclotron. Operating at the fourth harmonic of the RF with a peak voltage of 150 kV, it almost doubles the present energy gain per turn in the 400-500 MeV range, and reduces by ∼50% the stripping loss of the H - beam. This significant improvement will allow a substantial increase in the extracted current above the present routine level of 150μA while maintaining the same levels of residual radioactivity. The system is completed and being commissioned. A description of the design and commissioning procedures is presented, and results of beam tests given. (Author) 7 refs., 5 figs

  17. Isochronization calculations for the Indiana University cyclotron

    International Nuclear Information System (INIS)

    Jones, W.P.

    1975-01-01

    A series of calculations using measured magnetic fields was performed to determine the optimal gradient coil currents for the wide range of operating conditions to be experienced by the Indiana University main stage cyclotron. Depending on the particle type to be accelerated and final energy desired, the required radial field increase varies from 0.5 percent to 22 percent. An iterative least squares fitting technique is used to minimize orbit time variations. For the acceleration of 200 MeV protons (330 revolutions, fourth harmonic), the maximum phase excursion is predicted to be less than two rf degrees. The technique used can be adapted to using measured phase histories to predict corrections to gradient coil currents. (auth)

  18. Analysis of in-R12 CHF data: influence of hydraulic diameter and heating length; test of Weisman boiling crisis model

    International Nuclear Information System (INIS)

    Czop, V.; Herer, C.; Souyri, A.; Garnier, J.

    1993-09-01

    In order to progress on the comprehensive modelling of the boiling crisis phenomenon, Electricite de France (EDF), Commissariat a l'Energie Atomique (CEA) and FRAMATOME have set up experimental programs involving in-R12 tests: the EDF APHRODITE program and the CEA-EDF-FRAMATOME DEBORA program. The first phase in these programs aims to acquire critical heat flux (CHF) data banks, within large thermal-hydraulic parameter ranges, both in cylindrical and annular configurations, and with different hydraulic diameters and heating lengths. Actually, three data banks have been considered in the analysis, all of them concerning in-R12 round tube tests: - the APHRODITE data bank, obtained at EDF with a 13 mn inside diameter, - the DEBORA data bank, obtained at CEA with a 19.2 mm inside diameter, - the KRISTA data bank, obtained at KfK with a 8 mm inside diameter. The analysis was conducted using CHF correlations and with the help of an advanced mathematical tool using pseudo-cubic thin plate type Spline functions. Two conclusions were drawn: -no influence of the heating length on our CHF results, - the influence of the diameter on the CHF cannot be simply expressed by an exponential function of this parameter, as thermal-hydraulic parameters also have an influence. Some calculations with Weisman and Pei theoretical boiling crisis model have been compared to experimental values: fairly good agreement was obtained, but further study must focus on improving the modelling of the influence of pressure and mass velocity. (authors). 12 figs., 4 tabs., 21 refs

  19. Magnetic field optimisation and orbit calculation for VEC superconducting cyclotron

    International Nuclear Information System (INIS)

    Debnath, J.; Dey, M.K.; Mallik, C.; Bhandari, R.K.

    2003-01-01

    At VECC, Kolkata preparations are underway to measure the magnetic field of the cyclotron. Also once the superconducting cyclotron is assembled prediction of beam related parameters will be a very important exercise to carry out. Considering this the beam behaviour in the cyclotron will be crucial to achieve these goals. The present paper deals with the efforts in this direction and using a test beam of He 1+ 20 MeV/n the trim coil currents, the tune variation and the (r,Pr) behaviour of the central trajectory

  20. Design features and operating characteristics of the MC-50 cyclotron

    International Nuclear Information System (INIS)

    Bak, Hae Ill; Bak, Joo Shik

    1989-01-01

    The MC-50 cyclotron at Korean Cancer Center Hospital is now operational for neutron therapy and medical radioisotope production. Design features, mechanical structures and operating characteristics of the MC-50 are described in this paper. Optimum operating condition for this cyclotron has been determined by the repetitive running, and the performances of the internal beam have been investigated through the measurements of intensity and spatial distribution of the internal beam as a function of the radius of the cyclotron. Routinely, the 40 μA of 50 MeV protons have been obtained at first Faraday cup with a extraction efficiency of 61%. (Author)

  1. Health physics aspects of the 1.5M cyclotron

    International Nuclear Information System (INIS)

    Song, W.J.; Du, H.L.; Wei, Z.Q.; Xia, X.S.; Zheng, H.Z.; Jiang, G.F.; Liu, Y.Y.

    1987-01-01

    The 1.5m cyclotron in Institute of Modern Physics, Academia Sinica had operated for about 20 years until 1984 then converted to 1.7m sector focusing cyclotron. In this period it mainly used for fast neutron physics, light ion induced nucleus reactions, radioisotope production and heavy ion reactions. The health physics performed on this cyclotron including personnel dose monitoring, area monitoring (radiation field, radioactive aerosol, surface contamination and activated components etc.), maintenance inspection, environment survey and waste disposal is presented in this paper

  2. Thermal Stabilization of Cryogenic System in Superconducting Cyclotron

    International Nuclear Information System (INIS)

    Shin, Seung Jae; Kim, Kyung Min; Cho, Hyung Hee; Hong, Bong Hwan; Kang, Joon Sun; Ahn, Dong Hyun

    2011-01-01

    Radiology has some useful applications for medical purpose. For cancer therapy, the superconducting cyclotron should generate heavy ion beams. It radiates heavy ion beams to cancer patients. In order to make cyclotron system stable, the cryogenic system which makes superconducting state should work constantly. However, radiation heat transfer of cryogenic system should be considered because liquid helium's boiling point is extremely low and there is huge temperature difference between the cryogenic system and ambient temperature. Accordingly, thermal analysis should be carried out. In this paper, the numerical analysis of the cryogenic system in practical superconducting cyclotron show temperature distribution and suggest the number of coolers using ANSYS Workbench program

  3. Improving cancer treatment with cyclotron produced radionuclides. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Larson, S.M.; Finn, R.D.

    1993-11-01

    This report describes our continuing long term goal of promoting nuclear medicine applications by improving the scientific basis for tumor diagnosis, treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. The program includes 3 interactive components: Radiochemistry/Cyclotron; Pharmacology; and Immunology. An essential strategy is as follows: novel radionuclides and radiotracers developed in the Radiochemistry/Cyclotron section will be employed in the Pharmacology and Immunology sections during the next year. The development of novel radionuclides and tracers is of course useful in and of itself, but their utility is greatly enhanced by the interaction with the immunology and pharmacology components of the program.

  4. An experimental study on cyclotron-Cherenkov radiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C Y; Masuzaki, M; Yoshida, H; Toyosugi, N; Kamada, K; Ando, R [Kanazawa Univ. (Japan). Department of Physics

    1997-12-31

    Dielectric-loaded cylindrical waveguide configurations with an injected electron beam in which the growth rate of the cyclotron-Cherenkov instability surpasses that of the Cherenkov instability were sought by numerical treatment, and one configuration of this kind was found. This configuration consists of a metallic core and an outer metallic cylinder with a dielectric liner on the inner surface. Based on the calculations, an experimental device was designed and assembled to investigate experimentally radiation due to the cyclotron-Cherenkov instability. Beam propagation in the dielectric-loaded coaxial waveguide and microwave radiation due to the cyclotron-Cherenkov instability and the Cherenkov instability were studied. (author). 6 figs., 10 refs.

  5. Ion extraction in the cyclotron geometry

    International Nuclear Information System (INIS)

    Rodenburg, R.E.

    1985-01-01

    The detailed physics of ion beam extraction from a plasma column by intense sinusoidal radio frequency (rf) electric fields at the ion cyclotron frequency omega/sub ci/ and its harmonics is experimentally studied. Results describe the instantaneous relationship - within one rf period of approx. = 3009 nsec - between applied rf, the plasma response and the ions expelled by rf and plasma fields. Reflex discharges in H 2 , D 2 , and He with ion and electron densities greater than or equal to10 11 cm -3 are subjected to 0-5 kV zero-to-peak rf electric fields E vector and 0.65-9.00 kG background magnetic fields B 0 vector with E vector perpendicular to B 0 vector. Ion currents up to 200 μA are extracted. Nonperturbing optical diagnostics measure the relative amplitude and phase of instantaneous ion and electron density fluctuations induced by the rf during each rf cycle and the time variation of extracted ion bursts, the latter made possible by the use of a phosphor beam-stop. Detailed dependences on external electric and magnetic fields are reported. The plasma density fluctuations are in good agreement with the dispersion relation for electrostatic ion cyclotron waves (EICW), and the beam data show current enhancement at the second harmonic over that at the fundamental and evidence for a radically different mechanism for the rf-driven ion extraction process than conventional wisdom assumes. This work represents the first detailed, systematic study of the ac ion extraction process

  6. RNI Point-of-care test (POCT: esperança ou ilusão? Point-of-care test (POCT INR: hope or illusion?

    Directory of Open Access Journals (Sweden)

    Luci Maria Sant'Ana Dusse

    2012-06-01

    , INR point-of-care test (POCT INR, is the main test of this new proposal. This test has great potential benefit in situations where the quick INR results influences clinical decision making, as in acute ischemic stroke, before surgical procedures and during cardiac surgery. The INR POCT has the potential to be used for self-monitoring of oral anticoagulation in patients under anticoagulant therapy. However, the precision and accuracy of INR POCT still need to be enhanced to increase effectiveness and efficiency of the test. Additionally, the RDC / ANVISA Number 302 makes clear that the POCT testing must be supervised by the technical manager of the Clinical Laboratory in the pre-analytical, analytical and post-analytical. In practice, the Clinical Laboratory does not participate in the implementation of POCT testing or release of the results. Clinicians have high expectation with the incorporation of INR POCT in clinical practice, despite the limitations of this method. These professionals are willing to train the patient to perform the test, but are not legally responsible for the quality of it and are not prepared for the maintenance of equipment. The definition of who is in charge for the test must be one to ensure the quality control.

  7. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 23

    Energy Technology Data Exchange (ETDEWEB)

    1967-10-09

    Progress is reported in the design, installation of various components of the cyclotron, including coils, magnets, rf system, and vacuum system. Also reported are measurements on magnets and rf components. (LEW)

  8. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 20

    Energy Technology Data Exchange (ETDEWEB)

    1967-06-30

    Progress is reported in the fabrication and testing of cyclotron components, including magnet system and rf system components. Work on vacuum components and instrumentation and control equipment is also reported. (LEW)

  9. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 32

    Energy Technology Data Exchange (ETDEWEB)

    1968-06-28

    Completion of magnet tests, followed by completion of installation of major cyclotron components, are reported. Intermediate level power tests of the rf system are also reported. Design and fabrication of the control system are reported to be under way. (LEW)

  10. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 26

    Energy Technology Data Exchange (ETDEWEB)

    1968-01-17

    Progress is reported in the fabrication, installation, and testing of cyclotron components, including magnets and coils, rf components, vacuum and control equipment. Also reported are magnet and rf component measurements. (LEW)

  11. Cyclotron radiation by a multi-group method

    International Nuclear Information System (INIS)

    Chu, T.C.

    1980-01-01

    A multi-energy group technique is developed to study conditions under which cyclotron radiation emission can shift a Maxwellian electron distribution into a non-Maxwellian; and if the electron distribution is non-Maxwellian, to study the rate of cyclotron radiation emission as compared to that emitted by a Maxwellian having the same mean electron density and energy. The assumptions in this study are: the electrons should be in an isotropic medium and the magnetic field should be uniform. The multi-group technique is coupled into a multi-group Fokker-Planck computer code to study electron behavior under the influence of cyclotron radiation emission in a self-consistent fashion. Several non-Maxwellian distributions were simulated to compare their cyclotron emissions with the corresponding energy and number density equivalent Maxwellian distribtions

  12. Cryogenic system for VECC K500 superconducting cyclotron

    CERN Document Server

    Pal, G; Bhattacharyya, T K; Bhandari, R K

    2009-01-01

    VEC Centre, Kolkata in India is at an advanced stage of commissioning a K500 superconducting cyclotron. The superconducting coil of the magnet for cyclotron is cooled by liquid helium. Three liquid helium cooled cryopanels, placed inside the Dees of the radiofrequency system, maintain the vacuum in the acceleration region of the superconducting cyclotron. The cryogenic system for magnet for cyclotron has been tested by cooling the coil and energizing the magnet. The cryogenic system for cryopanels has also been tested. Heater and temperature sensor were placed on the liquid helium cold head for cryopanel. The temperature of the cold head was observed to be below 20 K upto a heat load of 11.7 watt.

  13. H-superconducting cyclotron for PET isotope production

    International Nuclear Information System (INIS)

    Smirnov, V.L.; Vorozhtsov, S.B.; Vincent, J.

    2014-01-01

    The scientific design of a 14-MeV H - compact superconducting cyclotron for producing of the 18 F and 13 N isotopes has been developed. Main requirements to the facility as a medical accelerator are met in the design. In particular, the main requirement for the cyclotron was the smallest possible size due to the superconducting magnet. The calculations show that the proposed cyclotron allows extracted beam intensity over 500 μA. To increase system reliability and production rates, an external H - ion source is applied. The choice of the cyclotron concept, design of the structure elements, calculation of the electromagnetic fields and beam dynamics from the ion source to the extraction system were performed.

  14. NORTICA—a new code for cyclotron analysis

    Science.gov (United States)

    Gorelov, D.; Johnson, D.; Marti, F.

    2001-12-01

    The new package NORTICA (Numerical ORbit Tracking In Cyclotrons with Analysis) of computer codes for beam dynamics simulations is under development at NSCL. The package was started as a replacement for the code MONSTER [1] developed in the laboratory in the past. The new codes are capable of beam dynamics simulations in both CCF (Coupled Cyclotron Facility) accelerators, the K500 and K1200 superconducting cyclotrons. The general purpose of this package is assisting in setting and tuning the cyclotrons taking into account the main field and extraction channel imperfections. The computer platform for the package is Alpha Station with UNIX operating system and X-Windows graphic interface. A multiple programming language approach was used in order to combine the reliability of the numerical algorithms developed over the long period of time in the laboratory and the friendliness of modern style user interface. This paper describes the capability and features of the codes in the present state.

  15. Cyclotrons for clinical and biomedical research with PET

    International Nuclear Information System (INIS)

    Wolf, A.P.

    1987-01-01

    The purpose of this commentary is to present some background material on cyclotrons and other particle accelerators particularly with a view toward the considerations behind acquiring and installing such a machine for purely clinical and/or biomedical research use

  16. Electron cyclotron resonance heating in a short cylindrical plasma ...

    Indian Academy of Sciences (India)

    The power mode conversion efficiency is estimated to be ... has also found application in electron cyclotron current drive (ECCD) in fusion ... (few GHz) of microwave sources, a small linear ECR plasma system can also serve ..... References.

  17. Development of baby cyclotron for PET in Korea

    International Nuclear Information System (INIS)

    Chai, J.S.; Kim, Y.S.; Hu, J.Y.; Shin, Y.C.; Yoon, M.H.

    2001-01-01

    Development of a 13 MeV cyclotron for Positron Emission Tomography (PET) has been in progress since April 1999 at the Korea Cancer Center Hospital (KCCH). The study has been carried out in a joint collaboration between KCCH and the Pohang University of Science and Technology (POSTECH). Increasing desire for an uninterrupted, reliable and timely supply of the isotopes to customers has prompted obtaining a dedicated 5-13 MeV cyclotron for PET applications and pursuing the purchase of another 30MeV medical cyclotron in the very near future. A decision has been made to design the PET cyclotron in Korea. This will not only ease the problems associated with maintenance during operation but also keep the door open for continuous upgrading of the machine in the future

  18. Remote machining and robotic welding in a proton cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, W; Mark, C

    1984-09-01

    Increasing residual radiation in the TRIUMF meson research facility cyclotron at the University of British Columbia has required development of a remotely operable industrial robot cutting and vacuum tight welding capabili

  19. The beam handling system of the Oslo Cyclotron

    International Nuclear Information System (INIS)

    Messelt, S.

    1985-11-01

    The beam optic system of the Oslo Cyclotron is described. A computer program for the calculation of optimal settings of quadropoles is presented. The reliability of the computer program is confirmed by experimental data

  20. Variable-Energy Cyclotron for Proton Therapy Application

    CERN Document Server

    Alenitsky, Yu G; Vorozhtsov, A S; Glazov, A A; Mytsyn, G V; Molokanov, A G; Onishchenko, L M

    2004-01-01

    The requirements to characteristics of the beams used for proton therapy are considered. The operation and proposed cyclotrons for proton therapy are briefly described. The technical decisions of creation of the cyclotron with energy variation in the range 70-230 MeV and with current up to 100 nA are estimated. Taking into account the fact, that the size and cost of the cyclotron are approximately determined by the maximum proton energy, it is realistically offered to limit the maximum proton energy to 190 MeV and to elaborate a cyclotron project with a warm winding of the magnet for acceleration of H^{-} ions. The energy of the extracted protons for each run is determined by a stripped target radius in the vacuum chamber of the accelerator, and the radiation dose field for the patient is created by the external devices using the developed techniques.

  1. Magnet design and test of positron emission tomography cyclotron

    International Nuclear Information System (INIS)

    Wei Tao; Yang Guojun; He Xiaozhong; Pang Jian; Zhao Liangchao; Zhang Kaizhi

    2012-01-01

    An 11 MeV H - compact cyclotron used for medical radioactive isotope production is under construction in Institute of Fluid Physics, CAEP. The cyclotron magnet adopts the design of small valley gaps and coulee structure which can provide high average magnetic field and strong focus ability. To achieve 5 × 10 -4 measuring accuracy, a magnetic field mapping system has been developed. After iterative correction using field measurement data, the total phase excursion of the cyclotron is within ± 9° and the first harmonic is less than 10 -3 T, which are all acceptable. Furthermore, the beam testing declares the successful construction of the cyclotron magnet. Besides, some magnetic field influence factors were discussed, including the magnetic field distortion and measurement error. (authors)

  2. Neutron field inside a PET Cyclotron vault room

    International Nuclear Information System (INIS)

    Vega C, H.R.; Mendez, R.; Iniguez, M.P.; Climent, J.M.; Penuelas, I.; Barquero, R.

    2006-01-01

    The neutron field around a Positron Emission Tomography cyclotron was investigated during 18 F radioisotope production with an 18 MeV proton beam. In this study the Ion Beam Application cyclotron, model Cyclone 18/9, was utilized. Measurements were carried out with a Bonner sphere neutron spectrometer with pairs of thermoluminescent dosemeters (TLD600 and TLD700) as thermal neutron detector. The TLDs readouts were utilized to unfold the neutron spectra at three different positions inside the cyclotron's vault room. With the spectra the Ambient dose equivalent was calculated. Neutron spectra unfolding were performed with the BUNKIUT code and the UTA4 response matrix. Neutron spectra were also determined by Monte Carlo calculations using a detailed model of cyclotron and vault room. (Author)

  3. On 'conflict of conservation laws in cyclotron radiation'

    International Nuclear Information System (INIS)

    White, S.M.; Parle, A.J.

    1985-01-01

    The authors reconsider the apparent conflict of conservation laws in cyclotron radiation, and show that earlier workers in this field did not correctly include the effects of radiation reaction in their calculations. When a 'recoil' term, calculated using relativistic quantum theory, is included in the angular momentum of the particle the conflict disappears. It is found that the guiding centre of the particle drifts outwards during cyclotron radiation. (author)

  4. The Medical Cyclotron Facility in RMC, Parel, BARC

    International Nuclear Information System (INIS)

    Gopalakrishna, Arjun; Banerjee, Sharmila

    2017-01-01

    The Medical Cyclotron Facility in Radiation Medicine Centre (RMC) is the first one of its kind, installed in 2002. "1"8F based radiotracers are produced in this facility on a routine basis for Positron Emission Tomography (PET), of in-house patients, as well as for supply to other nuclear medicine centers in Mumbai as well as Pune. The facility consists of the following sub parts - Cyclotron and support equipment; Radiochemistry synthesis laboratory; Quality control (QC) laboratory

  5. Channel of Axial Injection of DC-60 Cyclotron

    CERN Document Server

    Gikal, B N; Bogomolov, S L; Borisenko, A N; Borisov, O N; Gulbekyan, G G; Ivanenko, I A; Kalagin, I V; Kazacha, V I; Kazarinov, N Yu; Khabarov, M V; Lysukhin, S N; Melnikov, V N; Paschenko, S V; Tikhomirov, A V

    2006-01-01

    The design study and realization of the axial injection beam line of DC-60 cyclotron constructed at the Flerov Laboratory of Nuclear Reactions of the Joint Institute for Nuclear Research are given. The channel allows one to transport and to inject into the cyclotron ions with mass-to-charge ratio $A/Z$ being within interval A/Z=6-12 and kinetic energy up to 17 $Z/A$ keV/m.u.

  6. Ion-Beam-Excited Electrostatic Ion Cyclotron Waves

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1976-01-01

    Self-excited electrostatic ion cyclotron waves were observed in an ion-beam-plasma system produced in a DP-operated Q-machine. The frequency of the waves showed the theoretically predicted variation with the magnetic field.......Self-excited electrostatic ion cyclotron waves were observed in an ion-beam-plasma system produced in a DP-operated Q-machine. The frequency of the waves showed the theoretically predicted variation with the magnetic field....

  7. Parameters of the eigenellipsoid for separated sector cyclotrons

    International Nuclear Information System (INIS)

    Ferme, J.

    1989-01-01

    The analytical expressions of the elements of the beam matrix corresponding to the eigenellipsoid for a beam injected on an equilibrium orbit of a cyclotron are presented. The four dimensional phase space of the horizontal plane is only considered. Some restrictive hypotheses are made: there is no acceleration, and space charge effects are not taken into account. The beam matrix has been computed for the general case of spiraled sectors cyclotrons, and is valid for any given azimuth

  8. Process of a cyclotron modeling with SNOP program

    International Nuclear Information System (INIS)

    Smirnov, V.L.

    2015-01-01

    The description of the SNOP program developed in JINR and intended for numerical modeling of a beam dynamics in accelerating setups of cyclotron type is presented. The main methods of work with program components, and also stages of numerical modeling of a cyclotron, the analysis of the main characteristics of the accelerated bunch by means of the SNOP are given. The explanation of some algorithms and procedures used in the program is given. [ru

  9. Design study of electrostatic inflector in compact cyclotron injection system

    International Nuclear Information System (INIS)

    Zhang Tianjue; Fan Mingwu

    1996-01-01

    The beam dynamics behaviour in electrostatic inflector is investigated for a vertical type injection system to a compact cyclotron. The computer aided design and matching of the inflector are based on the simulation of computed beam orbit. Modeling and simulation are done on PC-486 to form a software package. The software package can be used to develop a new type cyclotron design combining with the software package CYCCAE developed by China Institute of Atomic Energy three years ago

  10. Wave trajectory and electron cyclotron heating in toroidal plasmas

    International Nuclear Information System (INIS)

    Maekawa, T.; Tanaka, S.; Terumichi, Y.; Hamada, Y.

    1977-12-01

    Wave trajectories propagating obliquely to magnetic field in toroidal plasmas are studied theoretically. Results show that the ordinary wave at appropriate incident angle is mode-converted to the extraordinary wave at first turning point and is further converted to the electron Bernstein wave during passing a loop or a hooked nail curve near second turning point and is cyclotron-damped away, resulting in local electron heating, before arriving at cyclotron resonance layer. (auth.)

  11. Mass measurements with the CIME cyclotron at GANIL

    International Nuclear Information System (INIS)

    Hornillos, M B Gomez; Chartier, M; Mittig, W; Blank, B; Chautard, F; Demonchy, C E; Gillibert, A; Jacquot, B; Jurado, B; Lecesne, N; Lepine-Szily, A; Orr, N A; Roussel-Chomaz, P; Savajols, H; Villari, A C C

    2005-01-01

    A new direct technique using the CIME cyclotron as a high-resolution mass spectrometer is being developed in order to measure the masses of exotic nuclei. Tests have been performed to check the feasibility of the method with a mixed beam of stable ions extracted from the SPIRAL ion source and injected into the CIME cyclotron. Preliminary results obtained with this new technique are presented and discussed

  12. Stability and nonlinear dynamics of gyrotrons at cyclotron harmonics

    International Nuclear Information System (INIS)

    Saraph, G.P.; Nusinovich, G.S.; Antonsen, T.M. Jr.; Levush, B.

    1992-01-01

    Gyrotrons operating at higher harmonics of the cyclotron frequency can overcome the frequency limitations caused by achievable strength of the magnetic field. However, the excitation of modes at the fundamental frequency exhibit a major problem for stable operation of harmonic gyrotron at high power with high efficiency. Therefore the issues of stability of gyrotron operation at the cyclotron harmonics and nonlinear dynamics of mode interaction are of great importance. The results of the authors stability analysis and multimode simulation are presented here. A detailed nonlinear theory of steady state single mode operation at cyclotron harmonics has been presented previously, taking into account beam-wave coupling and nonlinear gain function at cyclotron harmonics. A set of equations describing low gain regime interaction of modes resonant at different cyclotron harmonics was studied before. The multifrequency time-dependent nonlinear analysis presented here is based on previous gyrotron studies and beam-wave interaction at cyclotron harmonics. The authors have determined the parameter space for stable single mode operation at the second harmonic. The nonlinear dynamics of mode evolution and mode interaction for a harmonic gyrotron is presented. A new nonlinear effect in which the parasite at the fundamental harmonic helps excite the operating mode at the second harmonic has been demonstrated

  13. Rf structure of superconducting cyclotron for therapy application

    International Nuclear Information System (INIS)

    Takekoshi, Hidekuni; Matsuki, Seishi; Mashiko, Katuo; Shikazono, Naomoto.

    1981-01-01

    Advantages of fast neutrons in therapeutical application are now widely recognized. Fast neutrons are generated by bombarding a thick beryllium target with high energy protons and deuterons. The AVF cyclotrons which deliver 50 MeV protons and 25 MeV deuterons are commonly used and are commercially available now. At the treatment usually rotational irradiation is taken to prevent an injury to normal tissue from the high LET effect of fast neutrons. The construction cost of both cyclotrons and isocentric irradiation installation are relatively high, so that the spread of neutron therapy is obstructed. A superconducting cyclotron for neutron therapy application was proposed by a Chalk River group. This low cost design allows the installation to be a dedicated facility located in a hospital, and small size allows installations of the complete cyclotron in a rotatable gantry. The design studies of the superconducting cyclotron based on this idea are going on at Kyoto University. The full scale model experiments for a rf structure of the cyclotron were carried out. (author)

  14. A mobile superconducting cyclotron for PET and neutron radiography

    International Nuclear Information System (INIS)

    Griffiths, R.

    1988-01-01

    The report addresses the development of a mobile superconducting cyclotron for PET (positron emission tomography) and neutron radiography. Proposals for an ultralight cyclotron were made by Finlan et al., who suggested a novel technique of utilising a superconducting magnet with RF acceleration and iron sectors contained within the room temperature bore of the magnet. Detailed design of a cyclotron based on this concept has progressed well at Oxford Instruments. The main design priorities were to minimise the weight and power consumption of the cyclotron. The cyclotron required a large amount of shielding to reduce either radiation background levels or stray magnetic field. Thus low background levels of radiation and magnetic field are key design criteria. The superconducting magnet has a mean field of 2.35 Tesla and a room temperature bore diameter of 500 mm. Three pairs of profiled iron sectors placed in the center of the warm bore of the magnet provide an azimuthally varying magnetic field. This permits the use of high beam currents with low background. A novel technique is incorporated to reduce the stray magnetic field and radiation from the cyclotron. The RF system consists of three pairs of resonators mounted within the warm bore of the magnet between the iron sectors. (Nogami, K.)

  15. Ion source and injection line for high intensity medical cyclotron

    Science.gov (United States)

    Jia, XianLu; Guan, Fengping; Yao, Hongjuan; Zhang, TianJue; Yang, Jianjun; Song, Guofang; Ge, Tao; Qin, Jiuchang

    2014-02-01

    A 14 MeV high intensity compact cyclotron, CYCIAE-14, was built at China Institute of Atomic Energy (CIAE). An injection system based on the external H- ion source was used on CYCIAE-14 so as to provide high intensity beam, while most positron emission tomography cyclotrons adopt internal ion source. A beam intensity of 100 μA/14 MeV was extracted from the cyclotron with a small multi-cusp H- ion source (CIAE-CH-I type) and a short injection line, which the H- ion source of 3 mA/25 keV H- beam with emittance of 0.3π mm mrad and the injection line of with only 1.2 m from the extraction of ion source to the medial plane of the cyclotron. To increase the extracted beam intensity of the cyclotron, a new ion source (CIAE-CH-II type) of 9.1 mA was used, with maximum of 500 μA was achieved from the cyclotron. The design and test results of the ion source and injection line optimized for high intensity acceleration will be given in this paper.

  16. A 30 MeV H- cyclotron for isotope production

    International Nuclear Information System (INIS)

    Milton, B.F.; Dawson, R.; Erdman, K.L.

    1989-05-01

    Because of an expanding market for radioisotopes there is a need for a new generation of cyclotrons designed specifically for this purpose. TRIUMF is cooperating with a local industrial company in designing and constructing such a cyclotron. It will be a four sector H - cyclotron, exploiting the newly developed high brightness multicusp ion source. This source with H - current capability in excess of 5 mA makes feasible accelerated H - beam intensities of up to 500 μA. Beam extraction is by stripping to H + in a thin graphite foil. Extraction of two high-intensity beams, with energy variable from 15 to 30 MeV is planned. The use of an external ion source, provision of a good vacuum in the acceleration region, and the careful choice of materials for components in the median plane leads to a cyclotron that will have low activation and can be easily serviced in spite of the very high operating beam intensities. A design extension to 70 MeV using many of the design features of the 30 MeV cyclotron can be easily made. Such a machine with a good quality variable energy beam is a highly desirable source of protons for isotope production, injection into higher energy high intensity acceleration, injection into higher energy high intensity accelerators, and as an irradiation facility for ocular melanomas. Design of the 30 MeV cyclotron is well advanced and construction is in progress

  17. Commercial cyclotrons. Part I: Commercial cyclotrons in the energy range 10 30 MeV for isotope production

    Science.gov (United States)

    Papash, A. I.; Alenitsky, Yu. G.

    2008-07-01

    A survey of commercial cyclotrons for production of medical and industrial isotopes is presented. Compact isochronous cyclotrons which accelerate negative hydrogen ions in the energy range 10 30 MeV have been widely used over the last 25 years for production of medical isotopes and other applications. Different cyclotron models for the energy range 10 12 MeV with moderate beam intensity are used for production of 11C, 13N, 15O, and 18F isotopes widely applied in positron emission tomography. Commercial cyclotrons with high beam intensity are available on the market for production of most medical and industrial isotopes. In this work, the physical and technical parameters of different models are compared. Possibilities of improving performance and increasing intensity of H- beams up to 2 3 mA are discussed.

  18. Proceedings of the 12. Joint Workshop on Electron Cyclotron Emission and Electron Cyclotron Heating

    International Nuclear Information System (INIS)

    Giruzzi, Gerardo

    2003-01-01

    The 12. Joint Workshop on Electron Cyclotron Emission and Electron Cyclotron Heating was held in Aix-en-Provence (France) from 13 to 16 May 2002. The meeting was hosted by the Association Euratom-CEA sur la Fusion (CEA/Cadarache, France), with additional financial support from: - Region Provence-Alpes Cote d'Azur - The City of Aix-en-Provence - Communaute de l'Agglomeration du Pays d'Aix - Thales Electron Devices (France) - Alstom Magnets and Superconductors (France) - Spinner GmbH (Germany). The members of the local organizing committee were: G. Giruzzi, M. Lennholm, R. Magne and V. Poli, from CEA/Cadarache. The composition of the International Programme Committee was the following: M. Bornatici (Italy), A. Costley (ITER), E. de la Luna (Spain), G. Giruzzi (France), W. Kasparek (Germany), B. Lloyd (UK), J. Lohr (USA), K. Sakamoto (Japan). The subjects of the meeting were classified in four main topics: Electron Cyclotron Theory; Electron Cyclotron Emission; Electron Cyclotron Heating and Current Drive Experiments; Electron Cyclotron Technology. The results presented in these topics have been summarised in the closing session by E. Westerhof, A. Kraemer-Flecken, T. Goodman and G. Bosia, respectively. The workshop was attended by 85 participants from 18 countries, providing 10 invited talks, 30 oral presentations and 50 posters. The success of the workshop is mainly due to the amount and quality of their work and of their presentations. The generosity of the sponsors, the selection and advice work of the International Programme Committee, as well as the contribution of the chairmen and of the summary speakers should also be warmly acknowledged. The papers in this collection have been reproduced directly from the authors' manuscripts, provided either as camera-ready texts or as pdf files. The constraints on the papers lengths and formats have been kept to a minimum, on purpose. This series of workshops has now reached a good level of maturity, with well established

  19. Electron cyclotron emission measurements during 28 GHz electron cyclotron resonance heating in Wendelstein WVII-A stellarator

    International Nuclear Information System (INIS)

    Hartfuss, H.J.; Gasparino, U.; Tutter, M.; Brakel, R.; Cattanei, G.; Dorst, D.; Elsner, A.; Engelhardt, K.; Erckmann, V.; Grieger, G.; Grigull, P.; Hacker, H.; Jaeckel, H.; Jaenicke, R.; Junker, J.; Kick, M.; Kroiss, H.; Kuehner, G.; Maassberg, H.; Mahn, C.; Mueller, G.; Ohlendorf, W.; Rau, F.; Renner, H.; Ringler, H.; Sardei, F.; Weller, A.; Wobig, H.; Wuersching, E.; Zippe, M.; Kasparek, W.; Mueller, G.A.; Raeuchle, E.; Schueller, P.G.; Schwoerer, K.; Thumm, M.

    1987-11-01

    Electron cyclotron emission measurements have been carried out on electron cyclotron resonance heated plasmas in the WENDELSTEIN VII-A Stellarator. Blackbody radiation from the thermalized plasma main body as well as radiation from a small amount of weakly relativistic suprathermal electrons has been detected. In addition sideband emission has been observed near the second harmonic of the heating line source. Harmonic generation and parametric wave decay at the upper hybrid layer may be a reasonable explanation. (orig.)

  20. Characterization of electron cyclotron resonance hydrogen plasmas

    International Nuclear Information System (INIS)

    Outten, C.A.

    1990-01-01

    Electron cyclotron resonance (ECR) plasmas yield low energy and high ion density plasmas. The characteristics downstream of an ECR hydrogen plasma were investigated as a function of microwave power and magnetic field. A fast-injection Langmuir probe and a carbon resistance probe were used to determine plasma potential (V p ), electron density (N e ), electron temperature (T e ), ion energy (T i ), and ion fluence. Langmuir probe results showed that at 17 cm downstream from the ECR chamber the plasma characteristics are approximately constant across the center 7 cm of the plasma for 50 Watts of absorbed power. These results gave V p = 30 ± 5 eV, N e = 1 x 10 8 cm -3 , and T e = 10--13 eV. In good agreement with the Langmuir probe results, carbon resistance probes have shown that T i ≤ 50 eV. Also, based on hydrogen chemical sputtering of carbon, the hydrogen (ion and energetic neutrals) fluence rate was determined to be 1 x 10 16 /cm 2 -sec. at a pressure of 1 x 10 -4 Torr and for 50 Watts of absorbed power. 19 refs

  1. Fourier transform ion cyclotron resonance mass spectrometry

    Science.gov (United States)

    Marshall, Alan G.

    1998-06-01

    As for Fourier transform infrared (FT-IR) interferometry and nuclear magnetic resonance (NMR) spectroscopy, the introduction of pulsed Fourier transform techniques revolutionized ion cyclotron resonance mass spectrometry: increased speed (factor of 10,000), increased sensitivity (factor of 100), increased mass resolution (factor of 10,000-an improvement not shared by the introduction of FT techniques to IR or NMR spectroscopy), increased mass range (factor of 500), and automated operation. FT-ICR mass spectrometry is the most versatile technique for unscrambling and quantifying ion-molecule reaction kinetics and equilibria in the absence of solvent (i.e., the gas phase). In addition, FT-ICR MS has the following analytically important features: speed (~1 second per spectrum); ultrahigh mass resolution and ultrahigh mass accuracy for analysis of mixtures and polymers; attomole sensitivity; MSn with one spectrometer, including two-dimensional FT/FT-ICR/MS; positive and/or negative ions; multiple ion sources (especially MALDI and electrospray); biomolecular molecular weight and sequencing; LC/MS; and single-molecule detection up to 108 Dalton. Here, some basic features and recent developments of FT-ICR mass spectrometry are reviewed, with applications ranging from crude oil to molecular biology.

  2. Inactivation of bacterial cells by cyclotron beams

    Energy Technology Data Exchange (ETDEWEB)

    Yatagai, F [Waseda Univ., Tokyo (Japan). School of Science and Engineering; Takahashi, T; Matsuyama, A

    1975-06-01

    B. subtilis spores, E. coli Bsub(s-1) and E. coli B/r were bombarded with ..cap alpha..-particles and heavy ions of carbon, nitrogen and oxygen accelerated in the IPCR Cyclotron. The RBE versus LETsub(infinity) curve for B. subtilis spores showed a maximum peak at 120 keV/..mu..m, while those for E. coli Bsub(s-1) and E. coli B/r declined without any maximum as LETsub(infinity) values increased. In the region of ..cap alpha..-particles, the effective inactivation cross section (Ssub(eff)) for these three strains increased with increasing LETsub(infinity), and the rates of increase in Ssub(eff) in the LET region from --30 to --150 keV/..mu..m were 15.0, 1.5 and 2.5 times for B. subtilis spores, E. coli Bsub(s-1) and E. coli B/r, respectively. In the case of B. subtilis spores, Ssub(eff) values for heavy ions were almost independent of their energies, but the other two strains showed a considerable dependence upon beam energy. The characteristic LET dependence of Ssub(eff) observed in this study was fairly well explained by the target theory based on microdose concept.

  3. The 200 MeV cyclotron facility

    International Nuclear Information System (INIS)

    1987-01-01

    Beams of protons with several different energies have now been successfully transported between the injector cyclotron SPC1 and the SSC. Some small modifications to the placement of steering magnets and diagnostic equipment have been made in the light of our operational experience, which should improve the ease of tuning this beamline. Proton beams up to 200 MeV in energy have been transported to the experimental areas, where experiments in nuclear physics have been successful conducted. Three of the experimental beamlines are now in operation. Beams of 66 MeV protons have also been transported to targets in the isotope production vault, without difficulty. Field mapping of the remaining quadrupoles on site has been completed. Installation of and alignment of magnets up to the beam swinger is also complete, although the beam tube itself, plus vacuum and diagnostic equipment must still be tackled. The beam swinger has been designed and detailed in the drawing office, and is now being manufactured locally. The beamline elements for the sepctrometer beamline remain to be purchased. A personal computer has been purchased for controlling the field-mapping equipment for the spectrometer magnets, which are being manufactured in this country. A number of computer programs have been written for conversion of calibrated quadrupole and dipole magnet field data to absolute current values for the control system. Other programs permit diagnostic measurements of beam profiles to be used to calculated the beam emittance, or to set steering magnets so that the beam is correctly aligned

  4. Electronic cyclotron radiation amplification in thermonuclear plasmas

    International Nuclear Information System (INIS)

    Ziebell, L.F.

    1983-01-01

    The amplified emission of electron cyclotron radiation near the fundamental frequency from an inhomogeneous, anisotropic plasma slab is investigated in a linear theory. Plasma polarization effects are consistently included. Expressions are developed in the WKB approximation for emission in the ordinary and the extraordinary modes, for propagation perpendicular to the magnetic field. Numerical results are given for the extraordinary mode, for which effects are strongest. For the case of a loss-cone-type electron momentum distribution, it is shown that the amplification is sensitively dependent on the ratio of parallel-to-perpendicular temperature and on inhomogeneities in the magnetic field. The dependence of the amplification on the distribution is further investigated by considering superpositions of loss-cone and Maxwellian components. It is show that the presence of a Maxwellian component in general reduces the emission relative to the pure loss-cone case, and situations occur in which a layer in the slab very effectively absorbs all the radiation amplified elsewhere. A peculiar behaviour of the refractive index, which occurs in the transition from the pure loss-cone to the pure Maxwellian case, is discussed. (author)

  5. Ferrite-guided cyclotron-resonance maser

    International Nuclear Information System (INIS)

    Jerby, Eli; Kesar, A.; Aharony, A.; Breitmeier, G.

    2002-01-01

    The concept of a cyclotron-resonance maser (CRM) with a ferrite loading incorporated in its waveguide is proposed. The CRM interaction occurs between the rotating electron beam and the em wave propagating along a longitudinally magnetized ferrite medium. The ferrite anisotropic permeability resembles the CRM susceptibility in many aspects, and particularly in their similar response to the axial magnetic field (the ferrite susceptibility can be regarded as a passive analog of the active CRM interaction). The ferrite loading slows down the phase velocity of the em wave and thus the axial (Weibel) mechanism of the CRM interaction dominates. The ferrite loading enables also a mechanism of spectral tunability for CRM's. The ferrite loading is proposed, therefore, as a useful ingredient for high-power CRM devices. A linear model of the combined ferrite-guided CRM interaction reveals its useful features. Future schemes may also incorporate ferrite sections functioning as isolators, gyrators, or phase shifters within the CRM device itself for selective suppression of backward waves and spurious oscillations, and for gain and efficiency enhancement

  6. Automation in irradiating target systems for cyclotrons

    International Nuclear Information System (INIS)

    Araujo, Sumair G.; Sciani, Valdir; Almeida, Rosemeire S.

    2000-01-01

    Nowadays, two cyclotron are being operated at IPEN-CNEN/SP: one model CV-28, capable of accelerating p, d, 3 He 4 and α, with energies of 24, 14, 36 and 28 MeV, respectively, and beam currents up to 30 μA; the other one, model cyclone 30, accelerates protons with energy of 30 MeV and currents up to 350 μ A. Both have the objective of irradiating targets both for radioisotope production for use in Nuclear Medicine, such as 67 Ga, 201 Tl, 111 In, 123 I, 18 F, and general research. The development of irradiating systems completely automatized was the objective of this work, always aiming to reduce the radiation exposition dose to the workers and to increasing the reliability of use of these systems, because very high activities are expected in these processes. In the automation, a Programmable Logical Controller (PLC) was used connected to a feedback net, to manage all the variables involved in the irradiation processes. The program of the PLC was developed using Simatic Step Seven (S7), Software from Siemens, where all the steps are supervised in screens at a microcomputer. The assembling and sequence of leading were developed using the software from Unisoft, that keeps the operator informed about the work being carried out, at any time. (author)

  7. Inactivation of bacterial cells by cyclotron beams

    International Nuclear Information System (INIS)

    Yatagai, Fumio; Takahashi, Tadashi; Matsuyama, Akira.

    1975-01-01

    B. subtilis spores, E. coli Bsub(s-1) and E. coli B/r were bombarded with α-particles and heavy ions of carbon, nitrogen and oxygen accelerated in the IPCR Cyclotron. The RBE versus LETsub(infinity) curve for B. subtilis spores showed a maximum peak at 120 keV/μm, while those for E. coli Bsub(s-1) and E. coli B/r declined without any maximum as LETsub(infinity) values increased. In the region of α-particles, the effective inactivation cross section (Ssub(eff)) for these three strains increased with increasing LETsub(infinity), and the rates of increase in Ssub(eff) in the LET region from --30 to --150 keV/μm were 15.0, 1.5 and 2.5 times for B. subtilis spores, E. coli Bsub(s-1) and E. coli B/r, respectively. In the case of B. subtilis spores, Ssub(eff) values for heavy ions were almost independent of their energies, but the other two strains showed a considerable dependence upon beam energy. The characteristic LET dependence of Ssub(eff) observed in this study was fairly well explained by the target theory based on microdose concept. (auth.)

  8. Ion cyclotron system design for KSTAR tokamak

    International Nuclear Information System (INIS)

    Hong, B. G.; Hwang, C. K.; Jeong, S. H.; Yoony, J. S.; Bae, Y. D.; Kwak, J. G.; Ju, M. H.

    1998-05-01

    The KSTAR (Korean Superconducting Tokamak Advanced Research) tokamak (R=1.8 m, a=0.5 m, k=2, b=3.5T, I=2MA, t=300 s) is being constructed to do long-pulse, high-b, advanced-operating-mode fusion physics experiments. The ion cyclotron (IC) system (in conjunction with an 8-MW neutral beam and a 1.5-MW lower hybrid system) will provide heating and current drive capability for the machine. The IC system will deliver 6 MW of RF power to the plasma in the 25 to 60 MHz frequency range, using a single four-strap antenna mounted in a midplane port. It will be used for ion heating, fast-wave current drive (FWCD), and mode-conversion current drive (MCCD). The phasing between current straps in the antenna will be adjustable quickly during operation to provide the capability of changing the current-drive efficiency. This report describes the design of the IC system hardware: the electrical characteristics of the antenna and the matching system, the requirements on the power sources, and electrical analyses of the launcher. (author). 7 refs., 2 tabs., 40 figs

  9. Ion cyclotron system design for KSTAR tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Hong, B. G.; Hwang, C. K.; Jeong, S. H.; Yoony, J. S.; Bae, Y. D.; Kwak, J. G.; Ju, M. H

    1998-05-01

    The KSTAR (Korean Superconducting Tokamak Advanced Research) tokamak (R=1.8 m, a=0.5 m, k=2, b=3.5T, I=2MA, t=300 s) is being constructed to do long-pulse, high-b, advanced-operating-mode fusion physics experiments. The ion cyclotron (IC) system (in conjunction with an 8-MW neutral beam and a 1.5-MW lower hybrid system) will provide heating and current drive capability for the machine. The IC system will deliver 6 MW of RF power to the plasma in the 25 to 60 MHz frequency range, using a single four-strap antenna mounted in a midplane port. It will be used for ion heating, fast-wave current drive (FWCD), and mode-conversion current drive (MCCD). The phasing between current straps in the antenna will be adjustable quickly during operation to provide the capability of changing the current-drive efficiency. This report describes the design of the IC system hardware: the electrical characteristics of the antenna and the matching system, the requirements on the power sources, and electrical analyses of the launcher. (author). 7 refs., 2 tabs., 40 figs.

  10. Electron cyclotron emission spectroscopy on thermonuclear plasmas

    International Nuclear Information System (INIS)

    Tubbing, B.J.D.

    1987-01-01

    Analysis of electron cyclotron emission (ECE) enables one to infer the radial profile of the electron temperature in tokamaks. The Dutch FOM institute for plasma physics has designed, built, installed and operated a grating polychromator for ECE measurements at JET. This thesis deals with a few instrumental aspects of this project and with applications of ECE measurements in tokamak physics studies. Ch. 3 and 4 deal with the wave transport in ECE systems. In Ch. 3 a method is developed to infer the mode conversion, which is a source for transmission losses, in a waveguide component from the antenna pattern of its exit aperture. In Ch. 4 the design and manufacture of the waveguide transition system to the grating polychromator are described. In Ch. 5 a method is reported for calibration of the spectrometers, based on the use of a microwave source which simulates a large area blackbody of very high temperature. The feasibility of the method is tested by applying it to two different ECE systems. In Ch. 6 a study of heat pulse propagation in tokamak plasma's, based on measurement of the electron temperature with the grating polychromator, is presented. 105 refs.; 48 figs.; 8 tabs

  11. A small low energy cyclotron for radioisotope measurements

    International Nuclear Information System (INIS)

    Bertsche, K.J.

    1989-11-01

    Direct detection of 14 C by accelerator mass spectrometry has proved to be a much more sensitive method for radiocarbon dating than the decay counting method invented earlier by Libby. A small cyclotron (the ''cyclotrino'') was proposed for direct detection of radiocarbon in 1980. This combined the suppression of background through the use of negative ions, which had been used effectively in tandem accelerators, with the high intrinsic mass resolution of a cyclotron. Development of a small electrostatically-focused cyclotron for use as a mass spectrometer was previously reported but the sensitivity needed for detection of 14 C at natural abundance was not achieved. The major contributions of this work are the integration of a high current external ion source with a small flat-field, electrostatically-focused cyclotron to comprise a system capable of measuring 14 C at natural levels, and the analysis of ion motion in such a cyclotron, including a detailed analysis of phase bunching and its effect on mass resolution. A high current cesium sputter negative ion source generates a beam of carbon ions which is pre-separated with a Wien filter and is transported to the cyclotron via a series of electrostatic lenses. Beam is injected radially into the cyclotron using electrostatic deflectors and an electrostatic mirror. Axial focusing is entirely electrostatic. A microchannel plate detector is used with a phase-grated output. In its present form the system is capable of improving the sensitivity of detecting 14 C in some biomedical experiments by a factor of 10 4 . Modifications are discussed which could bring about an additional factor of 100 in sensitivity, which is important for archaeological and geological applications. Possibilities for measurements of other isotopes, such as 3 H, and 10 Be, and 26 Al, are discussed. 70 refs

  12. Relationship between general safety requirements and safety culture in the improvement of safe operation of I.N.R. TRIGA reactor facilities

    International Nuclear Information System (INIS)

    Ciocanescu, M.; Preda, M.; Chiritescu, M.; Dumitru, M.

    1996-01-01

    Acquiring of the basic principles of ''safety culture'' by a large number of profesionals in the nuclear field drew the attention of the decision factors in the INR managerial structure, who decided to promote certain practical actions at each level in order to improve nuclear safety. Starting from the ''Republican Standards for Nuclear Safety'' issued by CSEN in 1975, where general safety criteria are defined for nuclear reactors and NPPs, the specialists at the TRIGA reactor originated and implemented a coherent and secure system to ensure nuclear safety over all steps of nuclear activities: research, conception, execution, commissioning and operation. This system has been continuosly corrected so that now it is completely integrated in a modern safety system. The paper presents the way in which a modern system for nuclear safety at the TRIGA reactor has been implemented and developed, in accordance to specific criteria and requirements imposed by related National Regulations and with the principles of safety culture. Starting from the definition of specific responsabilities, there are presented the internal stipulations and practical actions at all levels in order to enhance nuclear safety. (orig.)

  13. Opposing Post-transcriptional Control of InR by FMRP and LIN-28 Adjusts Stem Cell-Based Tissue Growth

    Directory of Open Access Journals (Sweden)

    Arthur Luhur

    2017-12-01

    Full Text Available Summary: Although the intrinsic mechanisms that control whether stem cells divide symmetrically or asymmetrically underlie tissue growth and homeostasis, they remain poorly defined. We report that the RNA-binding protein fragile X mental retardation protein (FMRP limits the symmetric division, and resulting expansion, of the stem cell population during adaptive intestinal growth in Drosophila. The elevated insulin sensitivity that FMRP-deficient progenitor cells display contributes to their accelerated expansion, which is suppressed by the depletion of insulin-signaling components. This FMRP activity is mediated solely via a second conserved RNA-binding protein, LIN-28, known to boost insulin signaling in stem cells. Via LIN-28, FMRP controls progenitor cell behavior by post-transcriptionally repressing the level of insulin receptor (InR. This study identifies the stem cell-based mechanism by which FMRP controls tissue adaptation, and it raises the possibility that defective adaptive growth underlies the accelerated growth, gastrointestinal, and other symptoms that affect fragile X syndrome patients. : Luhur et al. report that FMRP acts via LIN-28 in progenitor cells to dampen the adaptive expansion of intestinal tissue in the fruit fly, raising the possibility that defective LIN28-mediated adaptive growth underlies some of the symptoms that affect fragile X syndrome patients. Keywords: FMRP, fmr1, LIN-28, insulin receptor, IIS, adaptive growth, tissue resizing, intestinal stem cell, insulin sensitivity

  14. Risk assessment of 30 MeV cyclotron facilities

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Gyo Seong; Lee, Jin Woo [Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of); Kim, Chong Yeal [Dept. of Radiation Science and Technology, Chonbuk National University, Jeonju (Korea, Republic of)

    2017-03-15

    A cyclotron is a kind of particle accelerator that produces a beam of charged particles for the production of medical, industrial, and research radioisotopes. More than 30 cyclotrons are operated in Korea to produce 18F, an FDG synthesis at hospitals. A 30-MeV cyclotron was installed at ARTI (Advanced Radiation Technology Institute, KAERI) mainly for research regarding isotope production. In this study, we analyze and estimate the items of risk such as the problems in the main components of the cyclotron, the loss of radioactive materials, the leakage of coolant, and the malfunction of utilities, fres and earthquakes. To estimate the occurrence frequency in an accident risk assessment, five levels, i.e., Almost certain, Likely, Possible, Unlikely, and Rare, are applied. The accident consequence level is classified under four grades based on the annual permissible dose for radiation workers and the public in the nuclear safety law. The analysis of the accident effect is focused on the radioactive contamination caused by radioisotope leakage and radioactive material leakage of a ventilation filter due to a free. To analyze the risks, Occupation Safety and Health Acts is applied. In addition, action plans against an accident were prepared after a deep discussion among relevant researchers. In this acts, we will search for hazard and introduce the risk assessment for the research 30-MeV cyclotron facilities of ARTI.

  15. Design of RF system for CYCIAE-230 superconducting cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Zhiguo, E-mail: bitbearAT@hotmail.com; Ji, Bin; Fu, Xiaoliang; Cao, Xuelong; Zhao, Zhenlu; Zhang, Tinajue

    2017-05-11

    The CYCIAE230 is a low-current, compact superconducting cyclotron designed for proton therapy. The Radio Frequency system consists of four RF cavities and applies second harmonic to accelerate beams. The driving power for the cavity system is estimated to be approximately 150 kW. The LLRF controller is a self-made device developed and tested at low power using a small-scale cavity model. In this paper, the resonator systems of an S.C. cyclotron in history are reviewed. Contrary to those RF systems, the cavities of the CYCIAE230 cyclotron connect two opposite dees. Two high-power RF windows are included in the system. Each window carries approximately 75 kW RF power from the driver to the cavities. Thus, the RF system for the CY-CIAE230 cyclotron is operated in driven push–pull mode. The two-way amplifier-coupler-cavity systems are operated with approximately the same amount of RF power but 180° out of phase compared with each other. The design, as well as the technical advantage and limitations of this operating mode, of the CYCIAE230 cyclotron RF system is analyzed.

  16. The PET / cyclotron facility at Putrajaya Hospital - an update

    International Nuclear Information System (INIS)

    Siti Najila Mohd Janib; Suzilawati Muhd Sarowi; Munira Shaikh Nasir; Zulkifli Mohamed Hashim

    2006-01-01

    Malaysia desire to have a cyclotron for nuclear medical use came into realisation recently with the establishment of a PET/Cyclotron Facility at Putrajaya Hospital. The testing and commissioning of the cyclotron, hot cells, QC equipment and PET/CT started on March 27, culminating in the first patient to be injected on May 10 2006. Three other patients were to be followed on May 15. The patients from both the Kuala Lumpur and Putrajaya Hospital were pre-selected by physicians from these hospitals. The 18 MeV cyclotron is capable of generating 16.4 MeV protons and 8.4 MeV deuterons. The cyclotron at Putrajaya has three targets (2 liquid and 1 gas) and is capable of producing 18 F-FDG and 18 F-DOPA. To complement this, the facility has 2 modules for FDG synthesis, 1 for F-DOPA and 1 for nucleophilic synthesis. The facility will be GMP compliant. For the first production for human use, the water-18 target was irradiated for 50 minutes at 20 mA to produce 1.3 Ci of F-18. At the end of synthesis, the activity of the FDG obtained was 600 mCi. The product was then injected to a 26-year-old female, with a suspected adenocarcinoma. (Author)

  17. Radiation protection problems by the operation of the cyclotron facility

    International Nuclear Information System (INIS)

    Durcik, M.; Nikodemova, D.

    1998-01-01

    The Cyclotron Center in Bratislava will consist of two cyclotrons. First - cyclotron DC-72 with maximal energy of 72 MV for protons for making experiments, for teaching process, for radioisotope production as 123 I and for neutron and proton therapy. Second - compact cyclotron with maximal proton energy of 18 MeV will be used for radioisotopes production for medical diagnosis as 1 *F (fluorodeoxyglucose), 81 Rb/ 81 Kr generator. This paper deals with the radiation protection problems by the operation of tis cyclotron facility as radiation protection of workers, monitoring plan, ventilation, safety lock and limitation and radiation monitoring. For proposed and continuing practices at the accelerator facility, the following general principles have to be fulfilled: (1) practices should produce sufficient benefit to offset the radiation detriment they case (justification); (2) the magnitude of the individual doses should be kept as low as achievable (optimization of protection); (3) individual exposures are subject to dose limits and some control of risk from potential exposures (dose and risk limits)

  18. Power deposition for ion cyclotron heating in large tokamaks

    International Nuclear Information System (INIS)

    Hellsten, T.; Villard, L.

    1988-01-01

    The power deposition profiles during minority ion cyclotron heating are analysed in large tokamaks by using the global, toroidal wave code LION. For tokamaks with large aspect ratio and with circular cross-section, the wave is focused on the magnetic axis and can be absorbed there by cyclotron absorption when the cyclotron resonance passes through the magnetic axis. The power deposition profile is then essentially determined by the Doppler broadening of the ion cyclotron resonance. For equilibria either non-circular or with a small aspect ratio the power deposition profile depends also on the strength of the damping. In this case the power deposition profile can be expressed as a sum of two power deposition profiles. One is related to the power absorbed in a single pass, and its shape is similar to that obtained for large aspect ratio and circular cross-section. The other profile is obtained by calculating the power deposition in the limit of weak damping, in which case the wave electric field is almost constant along the cyclotron resonance layer. A heuristic formula for the power deposition is given. The formula includes a number of calibration curves and functions which has been calculated with the LION code for JET relevant equilibria. The formula enables calculation of the power deposition profile in a simple way when the launched wave spectrum and damping coefficients are known. (author). 7 refs, 11 figs

  19. Design of RF system for CYCIAE-230 superconducting cyclotron

    Science.gov (United States)

    Yin, Zhiguo; Ji, Bin; Fu, Xiaoliang; Cao, Xuelong; Zhao, Zhenlu; Zhang, Tinajue

    2017-05-01

    The CYCIAE230 is a low-current, compact superconducting cyclotron designed for proton therapy. The Radio Frequency system consists of four RF cavities and applies second harmonic to accelerate beams. The driving power for the cavity system is estimated to be approximately 150 kW. The LLRF controller is a self-made device developed and tested at low power using a small-scale cavity model. In this paper, the resonator systems of an S.C. cyclotron in history are reviewed. Contrary to those RF systems, the cavities of the CYCIAE230 cyclotron connect two opposite dees. Two high-power RF windows are included in the system. Each window carries approximately 75 kW RF power from the driver to the cavities. Thus, the RF system for the CY-CIAE230 cyclotron is operated in driven push-pull mode. The two-way amplifier-coupler-cavity systems are operated with approximately the same amount of RF power but 180° out of phase compared with each other. The design, as well as the technical advantage and limitations of this operating mode, of the CYCIAE230 cyclotron RF system is analyzed.

  20. Cyclotron for industrial production of radioisotopes: relevants characteristics

    International Nuclear Information System (INIS)

    Lima, Wanderley de

    1997-01-01

    The industrial production of radioisotopes requests cyclotrons with easy maintenance services, high productivity and low operation costs. To obtain this performance the experts on the have achieved excellent results, taking advantage of modern resources in calculation and modeling. Only by the maximum exploitation of the azimutal variation of the magnetic field, a physical concept introduced in 1967 with the isocronous cyclotrons, it was possible to construct cyclotrons with only 30% of the electrical consumption required by the former cyclotrons. On the other hand, the acceleration of negative ions enable the 100% accelerated beam utilization, without internal energy dissipation, obtaining beam intensities up to 1mA in continuous running which represents an increased factor of 15. Other construction parameters were optimized aiming at reliability and reduction in the components activation. Concerning energy consumption and the beam intensity supplied, a present cyclotron with 30 MeV and 300μA of protons current is 15 times more efficient than its precedent. (author). 6 refs., 1 fig., 2 tabs

  1. Potential of cyclotron based accelerators for energy production and transmutation

    Energy Technology Data Exchange (ETDEWEB)

    Stammbach, T.; Adam, S.; Fitze, H.R. [Paul Scherrer Institute, Villigen (Switzerland)] [and others

    1995-10-01

    PSI operates a 590 MeV-cyclotron facility for high intensity proton beams for the production of intense beams of pions and muons. The facility, commissioned in 1974, has been partially upgraded and is now operated routinely at a beam current of 1 mA, which corresponds to a beam power of 0.6 MW. At this current, the beam losses in the cyclotron are about 0.02%. By the end of 1995 the authors expect to have 1.5 mA of protons. Extensive theoretical investigations on beam current limitations in isochronous cyclotrons were undertaken. They show that the longitudinal space charge effects dominate. Based on their experience the authors present a preliminary design of a cyclotron scheme that could produce a 10 MW beam as a driver for an {open_quotes}energy amplifier{close_quotes} as proposed by C. Rubbia and his collaborators. The expected efficiency for the conversion of AC into beam power would be about 50% (for the RF-systems only). The beam losses in the cyclotron are expected to be a few {mu}A, leading to a tolerable activation level.

  2. Risk assessment of 30 MeV cyclotron facilities

    International Nuclear Information System (INIS)

    Jeong, Gyo Seong; Lee, Jin Woo; Kim, Chong Yeal

    2017-01-01

    A cyclotron is a kind of particle accelerator that produces a beam of charged particles for the production of medical, industrial, and research radioisotopes. More than 30 cyclotrons are operated in Korea to produce 18F, an FDG synthesis at hospitals. A 30-MeV cyclotron was installed at ARTI (Advanced Radiation Technology Institute, KAERI) mainly for research regarding isotope production. In this study, we analyze and estimate the items of risk such as the problems in the main components of the cyclotron, the loss of radioactive materials, the leakage of coolant, and the malfunction of utilities, fres and earthquakes. To estimate the occurrence frequency in an accident risk assessment, five levels, i.e., Almost certain, Likely, Possible, Unlikely, and Rare, are applied. The accident consequence level is classified under four grades based on the annual permissible dose for radiation workers and the public in the nuclear safety law. The analysis of the accident effect is focused on the radioactive contamination caused by radioisotope leakage and radioactive material leakage of a ventilation filter due to a free. To analyze the risks, Occupation Safety and Health Acts is applied. In addition, action plans against an accident were prepared after a deep discussion among relevant researchers. In this acts, we will search for hazard and introduce the risk assessment for the research 30-MeV cyclotron facilities of ARTI

  3. Study of first harmonic field effects on beam extraction for VEC K500 superconducting cyclotron

    International Nuclear Information System (INIS)

    Dey, M.K.; Debnath, J.; Mallik, C.; Bhandari, R.K.

    2002-01-01

    In superconducting cyclotron large momentum compaction at extraction region makes the turn separation very small. The first harmonic effects on the He +1 beam using simulated magnetic field for VEC K500 cyclotron is reported

  4. Reduction of the beam pulse repetition rate of the Hamburg Isochronous Cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Krause, H; Langkau, R; Schirm, N [Hamburg Univ. (F.R. Germany). 1. Inst. fuer Experimentalphysik

    1976-04-01

    A system for the reduction of the beam pulse repetition rate of the energy-variable Hamburg Isochronous Cyclotron comprising beam pulse supression in the cyclotron center and in the external beam is described.

  5. Superconducting cyclotron deflector conditioning status - an experience with high voltage

    International Nuclear Information System (INIS)

    Ghosh, Subhash; Chattopadhyay, Subrata; Bhattacharjee, Tanushyam; De, Anirban; Paul, Santanu; Pal, Gautam; Saha, Subimal; Mallik, C.; Bhandari, R.K.

    2009-01-01

    In this paper we report about the status of the electrostatic deflector which will be used in K500 superconducting cyclotron at VECC, Kolkata. For extraction of beams from superconducting cyclotron we have to achieve 130 kV/cm. Titanium and tungsten are used for anode and septum respectively. The deflector fits within the median plane of the superconducting magnet. We report here the voltage limit, sparking rates, dark current levels and the effects observed on conditioning. For commissioning of the superconducting cyclotron, the plan is to accelerate Neon beam of 50 MeV/n for which the required extraction voltage is 81 kV/cm and we reached up to 110 kV/cm. The conditioning test chamber is maintained at a pressure of 8.0 x 10 -7 mbar. (author)

  6. Electron cyclotron waves, transport and instabilities in hot plasmas

    International Nuclear Information System (INIS)

    Westerhof, E.

    1987-01-01

    A number of topics relevant to the magnetic confinement approach to the thermonuclear fusion is addressed. The absorption and emission of electron cyclotron waves in a thermal plasma with a small population of supra-thermal, streaming electrons is examined and the properties of electron cyclotron waves in a plasma with a pure loss-cone distribution are studied. A report is given on the 1-D transport code simulations that were performed to assist the interpretation of the electron cyclotron heating experiments on the TFR tokamak. Transport code simulations of sawteeth discharges in the T-10 tokamak are discussed in order to compare the predictions of different models for the sawtooth oscillations with the experimental findings. 149 refs.; 69 figs.; 7 tabs

  7. Radioisotope production by reactors and cyclotrons in Japan

    International Nuclear Information System (INIS)

    Murakami, Yukio

    1978-01-01

    Present status of radioisotope production in Japan and the increasing demand from various fields are generally reviewed. Future problems associated with the shortage of economical supply are also discussed. The first half of this report is devoted to general review of the increasing demand for various radioisotopes from increasing number of users. The present status and future trends of the distribution of users of specific radioisotopes and their demands are shown. The remaining half of this report reviews the production with reactors and cyclotrons. The Japanese reactors producing radioisotopes are limited to low flux (10 13 ) research reactors at JAERI. Some problems associated with the improvement of availability and with the organizational structure are discussed. As for the production with cyclotrons, available facilities and the method of production are explained in detail. For clinical use, especially for the production of short lived radioisotopes, the advantage of a small special purpose cyclotron at each medical organization is emphasized. (Aoki, K.)

  8. CACTUS - a multidetector set-up at the Oslo Cyclotron

    International Nuclear Information System (INIS)

    Guttormsen, M.; Bjerke, B.; Messelt, S.; Olsen, E.A.; Ramsoey, T.; Rekstad, J.; Tveter, T.S.; Wikne, J.C.; Kownacki, J.

    1989-06-01

    The design and construction of the multidetector system CACTUS is discussed, and its operation in the context of the Oslo Cyclotron is described. The multidetector system has been initiated to meet the requirements at the Oslo Cyclotron Laboratory in the experimental work on nuclear structure at high intrinsic excitation energy. The laboratory has developed a promising technique based on measuring γ-decay after single nucleon transfer reactions with the use of pγ coincidences. However, a proper interpretation of the experimental results has often been difficult due to low counting rates. One of the most important aims for the new experimental set-up has been to obtain pγ as well as pγγ coincidence spectra with high statistics. The CACTUS detector system which is mounted on the 90 o beam line of the cyclotron, consists of 28 NaI and 2 Ge detectors in combination with 8 Si particle telescopes

  9. Electron Cyclotron Resonance Heating of a High-Density Plasma

    DEFF Research Database (Denmark)

    Hansen, F. Ramskov

    1986-01-01

    Various schemes for electron cyclotron resonance heating of tokamak plasmas with the ratio of electron plasma frequency to electron cyclotron frequency, "»pe/^ce* larger than 1 on axis, are investigated. In particular, a mode conversion scheme is investigated using ordinary waves at the fundamental...... of the electron cyclotron frequency. These are injected obliquely from the outside of the tokamak near an optimal angle to the magnetic field lines. This method involves two mode conversions. The ordinary waves are converted into extraordinary waves near the plasma cut-off layer. The extraordinary waves...... are subsequently converted into electrostatic electron Bernstein waves at the upper hybrid resonance layer, and the Bernstein waves are completely absorbed close to the plasma centre. Results are presented from ray-tracinq calculations in full three-dimensional geometry using the dispersion function for a hot non...

  10. Design study of the KIRAMS-430 superconducting cyclotron magnet

    International Nuclear Information System (INIS)

    Kim, Hyun Wook; Kang, Joonsun; Hong, Bong Hwan; Jung, In Su

    2016-01-01

    Design study of superconducting cyclotron magnet for the carbon therapy was performed at the Korea Institute of Radiological and Medical Science (KIRAMS). The name of this project is The Korea Heavy Ion Medical Accelerator (KHIMA) project and a fixed frequency cyclotron with four spiral sector magnet was one of the candidate for the accelerator type. Basic parameters of the cyclotron magnet and its characteristics were studied. The isochronous magnetic field which can guide the "1"2C"6"+ ions up to 430 MeV/u was designed and used for the single particle tracking simulation. The isochronous condition of magnetic field was achieved by optimization of sector gap and width along the radius. Operating range of superconducting coil current was calculated and changing of the magnetic field caused by mechanical deformations of yokes was considered. From the result of magnetic field design, structure of the magnet yoke was planned.

  11. Radiation monitoring in a self-shielded cyclotron installation

    International Nuclear Information System (INIS)

    Capaccioli, L.; Gori, C.; Mazzocchi, S.; Spano, G.

    2002-01-01

    As nuclear medicine is approaching a new era with the spectacular growth of PET diagnosis, the number of medical cyclotrons installed within the major hospitals is increasing accordingly. Therefore modern medical cyclotron are highly engineered and highly reliable apparatus, characterised with reduced accelerating energies (as the major goal is the production of fluorine 18) and often self-shielded. However specific dedicated monitors are still necessary in order to assure the proper radioprotection. At the Careggi University Hospital in Florence a Mini trace 10 MeV self-shielded cyclotron produced by General Electric has been installed in 2000. In a contiguous radiochemistry laboratory, the preparation and quality control of 1 8F DG and other radiopharmaceuticals takes place. Aim of this work is the characterisation and the proper calibration of the above mentioned monitors and control devices

  12. Isochronous variable energy cyclotron of IPEN-CNEN/SP (Brazil)

    International Nuclear Information System (INIS)

    Lucki, G.; Zanchetta, A.A.; Gouveia, S.; Klein, H.

    1984-01-01

    The cyclotron CV-28 installed at the Radiation Damage Division of IPEN-CNEN/SP is a multi-particle radiation source where protons, deuterons, 3 He ions and alpha particles can be accelerated with variable energy up to 24, 14, 36 and 28 MeV, respectively. The cyclotron is a versatile machine that can be applied in research and development of : radioisotope production - materials science - nuclear physics - activation analysis and others. First internal beam with 24 MeV protons has been obtained in April 23, 1981. First irradiation of Cu sample, at the external beam (beam current 1.5 μA), with 28 MeV alpha particles was performed in December 29, 1983. Main characteristics of the cyclotron are given together with a description of peripheral systems and experimental capability. Presently the accelerator is being optimized for cpontinuous running. (Author) [pt

  13. Design study of the KIRAMS-430 superconducting cyclotron magnet

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Wook; Kang, Joonsun, E-mail: genuinei@kirams.re.kr; Hong, Bong Hwan; Jung, In Su

    2016-07-01

    Design study of superconducting cyclotron magnet for the carbon therapy was performed at the Korea Institute of Radiological and Medical Science (KIRAMS). The name of this project is The Korea Heavy Ion Medical Accelerator (KHIMA) project and a fixed frequency cyclotron with four spiral sector magnet was one of the candidate for the accelerator type. Basic parameters of the cyclotron magnet and its characteristics were studied. The isochronous magnetic field which can guide the {sup 12}C{sup 6+} ions up to 430 MeV/u was designed and used for the single particle tracking simulation. The isochronous condition of magnetic field was achieved by optimization of sector gap and width along the radius. Operating range of superconducting coil current was calculated and changing of the magnetic field caused by mechanical deformations of yokes was considered. From the result of magnetic field design, structure of the magnet yoke was planned.

  14. Radiation effects testing at the 88-Inch Cyclotron at LBNL

    International Nuclear Information System (INIS)

    McMahan, Margaret A.; Koga, Rokotura

    2002-01-01

    The effects of ionizing particles on sensitive microelectronics is an important component of the design of systems as diverse as satellites and space probes, detectors for high energy physics experiments and even internet server farms. Understanding the effects of radiation on human cells is an equally important endeavor directed towards future manned missions in space and towards cancer therapy. At the 88-Inch Cyclotron at the Berkeley Laboratory, facilities are available for radiation effects testing (RET) with heavy ions and with protons. The techniques for doing these measurements and the advantages of using a cyclotron will be discussed, and the Cyclotron facilities will be compared with other facilities worldwide. RET of the same part at several facilities of varying beam energy can provide tests of the simple models used in this field and elucidate the relative importance of atomic and nuclear effects. The results and implications of such measurements will be discussed

  15. Automatized target devices for radioisotope production at the RITs cyclotron

    International Nuclear Information System (INIS)

    Bogdanov, P.V.; Ivanov, V.V.; Karasev, B.G.

    1981-01-01

    An automation target device intended for isotope production on the internal beam of the RITs cyclotron is decribed. The target device comprises the following main units: target head, vacuum lock, charging device, transport system for bringing the target for charging; mechanism of target discharge transport device, control interlocking and signalling control system of target radiation power. The automation target device permits radioisotope production on the cyclotron in commercial scales with automation substitution of irradiated targets. The time of substitution of one of six targets makes up only 5 min. The time of charging a new group of targets to the charge device - 60 min. Contact of the personnel with irradiated targets is practically excluded and the necessity of entering the cyclotron room for maintenance of the plant is reduced to the minimum [ru

  16. A 30 MeV H- cyclotron for isotope production

    International Nuclear Information System (INIS)

    Baartman, R.; Kleevan, W.J.; Laxdal, R.E.; Milton, B.F.; Otter, A.J.; Pearson, J.B.; Poirier, R.L.; Schmor, P.W.; Schneider, H.R.; Erdman, K.L.; Walker, Q.

    1989-01-01

    Because of an expanding market for radioisotopes there is a need for a new generation of cyclotrons designed specifically for this purpose. We describe such a cyclotron currently under construction. It is a 30 MeV H - design that exploits a newly developed high brightness multicusp ion source which is capable of H - currents of up to 5 mA. This together with careful beam matching then makes feasible accelerated H - beam intensities of 500 μA. The cyclotron being built is a four sector radial ridge design with two 45 degree dees in opposite valleys. Beam extraction is by stripping to H + in a thin graphite foil. Two extraction probes will allow simultaneous extraction of two beams, each with an intensity of up to 200 μA. Energy variation from 15 MeV to 30 MeV is achieved by varying the radial position of the extraction foil. 7 refs., 4 figs., 1 tab

  17. The Ion Cyclotron, Lower Hybrid, and Alfven Wave Heating Methods

    International Nuclear Information System (INIS)

    Koch, R.

    2004-01-01

    This lecture covers the practical features and experimental results of the three heating methods. The emphasis is on ion cyclotron heating. First, we briefly come back to the main non-collisional heating mechanisms and to the particular features of the quasilinear coefficient in the ion cyclotron range of frequencies (ICRF). The specific case of the ion-ion hybrid resonance is treated, as well as the polarisation issue and minority heating scheme. The various ICRF scenarios are reviewed. The experimental applications of ion cyclotron resonance heating (ICRH) systems are outlined. Then, the lower hybrid and Alfven wave heating and current drive experimental results are covered more briefly. Where applicable, the prospects for ITER are commented

  18. Nonlinear cyclotron-resonance accelerations by a generalized EM wave

    International Nuclear Information System (INIS)

    Akimoto, K.; Hojo, H.

    2004-01-01

    Particle accelerations by a one-dimensional, electromagnetic, dispersive pulse in an external magnetic field are investigated. It is found that the well-known cyclotron resonance may be classified into three regimes as the length and/or the amplitude of the pulse are varied. Namely, as the pulse amplitude increases, the transit-time cyclotron-resonance acceleration (CRA) evolves to phase trapping, and reflect particles. The amplitude and wave dispersion as well as the pulse length strongly affect those accelerations. The interesting phenomena of quantization of resonance velocities in between the two regimes are also investigated. This new mechanism may lead to wave amplification at some discrete frequencies other than the cyclotron frequency. (authors)

  19. Calibration of the simulation model of the VINCY cyclotron magnet

    Directory of Open Access Journals (Sweden)

    Ćirković Saša

    2002-01-01

    Full Text Available The MERMAID program will be used to isochronise the nominal magnetic field of the VINCY Cyclotron. This program simulates the response, i. e. calculates the magnetic field, of a previously defined model of a magnet. The accuracy of 3D field calculation depends on the density of the grid points in the simulation model grid. The size of the VINCY Cyclotron and the maximum number of grid points in the XY plane limited by MERMAID define the maximumobtainable accuracy of field calculations. Comparisons of the field simulated with maximum obtainable accuracy with the magnetic field measured in the first phase of the VINCY Cyclotron magnetic field measurements campaign has shown that the difference between these two fields is not as small as required. Further decrease of the difference between these fields is obtained by the simulation model calibration, i. e. by adjusting the current through the main coils in the simulation model.

  20. Stochasticity of the energy absorption in the electron cyclotron resonance

    International Nuclear Information System (INIS)

    Gutierrez T, C.; Hernandez A, O.

    1998-01-01

    The energy absorption mechanism in cyclotron resonance of the electrons is a present problem, since it could be considered from the stochastic point of view or this related with a non-homogeneous but periodical of plasma spatial structure. In this work using the Bogoliubov average method for a multi periodical system in presence of resonances, the drift equations were obtained in presence of a RF field for the case of electron cyclotron resonance until first order terms with respect to inverse of its cyclotron frequency. The absorbed energy equation is obtained on part of electrons in a simple model and by drift method. It is showed the stochastic character of the energy absorption. (Author)

  1. CAS CERN Accelerator School: Cyclotrons, linacs and their applications. Proceedings

    International Nuclear Information System (INIS)

    Turner, S.

    1996-01-01

    These proceedings present the lectures given at the eighth specialized course organized by the CERN Accelerator School (CAS), the topic this time being 'Cyclotrons, Linacs and Their Applications'. Following an introductory lecture on linacs, the fundamental features of electron, ion and induction linacs are described together with their RF systems and particle sources. Cyclotrons are then introduced followed by details of their different types, their magnet and RF design, and their injection and extraction systems, with a glance towards exotic and possible future machines. Chapters are then presented on the use of linacs and cyclotrons for medical, fission, fusion and material applications, as well as for isotope production. Finally, descriptions of the design of a radioisotope facility, the matching of accelerators to their task and the computational tools used in their design are included. (orig.)

  2. CAS CERN Accelerator School: Cyclotrons, linacs and their applications. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Turner, S [ed.

    1996-03-04

    These proceedings present the lectures given at the eighth specialized course organized by the CERN Accelerator School (CAS), the topic this time being `Cyclotrons, Linacs and Their Applications`. Following an introductory lecture on linacs, the fundamental features of electron, ion and induction linacs are described together with their RF systems and particle sources. Cyclotrons are then introduced followed by details of their different types, their magnet and RF design, and their injection and extraction systems, with a glance towards exotic and possible future machines. Chapters are then presented on the use of linacs and cyclotrons for medical, fission, fusion and material applications, as well as for isotope production. Finally, descriptions of the design of a radioisotope facility, the matching of accelerators to their task and the computational tools used in their design are included. (orig.).

  3. Band rejection filter for measurement of electron cyclotron emission during electron cyclotron heating

    International Nuclear Information System (INIS)

    Iwase, Makoto; Ohkubo, Kunizo; Kubo, Shin; Idei, Hiroshi.

    1996-05-01

    For the measurement of electron cyclotron emission from the high temperature plasma, a band rejection filter in the range of 40-60 GHz is designed to reject the 53.2 GHz signal with large amplitude from the gyrotron for the purpose of plasma electron heating. The filter developed with ten sets of three quarters-wavelength coupled by TE 111 mode of tunable resonant cavity has rejection of 50 dB and 3 dB bandwidth of 500 MHz. The modified model of Tschebysheff type for the prediction of rejection is proposed. It is confirmed that the measured rejection as a function of frequency agrees well with the experimental results for small coupling hole, and also clarified that the rejection ratio increases for the large coupling hole. (author)

  4. Electron cyclotron resonance plasmas and electron cyclotron resonance ion sources: Physics and technology (invited)

    International Nuclear Information System (INIS)

    Girard, A.; Hitz, D.; Melin, G.; Serebrennikov, K.

    2004-01-01

    Electron cyclotron resonance (ECR) ion sources are scientific instruments particularly useful for physics: they are extensively used in atomic, nuclear, and high energy physics, for the production of multicharged beams. Moreover, these sources are also of fundamental interest for plasma physics, because of the very particular properties of the ECR plasma. This article describes the state of the art on the physics of the ECR plasma related to multiply charged ion sources. In Sec. I, we describe the general aspects of ECR ion sources. Physics related to the electrons is presented in Sec. II: we discuss there the problems of heating and confinement. In Sec. III, the problem of ion production and confinement is presented. A numerical code is presented, and some particular and important effects, specific to ECR ion sources, are shown in Sec. IV. Eventually, in Sec. V, technological aspects of ECR are presented and different types of sources are shown

  5. Next customers to cyclotron center meanwhile are not entered

    International Nuclear Information System (INIS)

    Bato, R.; Zackova, K.

    2004-01-01

    In this paper the financial aspects of construction of the Cyclotron Centre of the Slovak Republic (CC SR) are analysed. This building represents the problems of exploitation of commodity deblocation of Russian Federation debt to Slovakia. The estimated expenses have risen from original planned 2 billion Slovak crowns to 6 billion Slovak crowns. Devices which should be part of centre - a cyclotron used for radiopharmaceuticals production for oncological purposes and a big cyclotron for industrial purposes, a centre of positron emissive tomography (PET), a laboratory of nano-technologies, a source of heavy ions - they indicates that the oncological institutes, departments of health service, of education, of economy, of defence, of environment, also Nuclear Regulatory Authority of Slovak Republic and Slovak Academy of Sciences should become the customers principally. Around 2.2 billion of Slovak crowns from deblocation have been spent for a construction of Cyclotron Centre of SR yet. The national budget has contributed by 95 million Slovak crowns; 90.5 million USD will be obtained from deblocation of Russian debt yet. IAEA has supported this centre by grant of almost 800 thousand USD. Budget of Cyclotron Centre of SR is still rising also because of rising of VAT from 10 percent to 19 percent. VAT will be paid also for goods imported within the framework of deblocation after integration of Slovak Republic to European Union; besides also 10 percent duty is paid. Project of CC SR has not passed the state expert opinion. Agreement for construction of Cyclotron Centre of SR was issued by State Health Institute of Bratislava, therefore it was confirmed also by the main hygienist of Slovak Republic

  6. Calculations for the design and modification of the 2 cyclotrons of S.A.R.A

    International Nuclear Information System (INIS)

    Albrand, P.S.; Belmont, J.L.; Ripouteau, F.

    1983-09-01

    S.A.R.A. is a heavy ion accelerator constituted by 2 cyclotrons. The second cyclotron (post-accelerator) was entirely calculated at the I.S.N. The pole tips of the first cyclotron which is much older, have recently been modified. An almost identical procedure was used for the calculation of each element of the post-accelerator of S.A.R.A. and also for the modifications to the first cyclotron

  7. Solid targets for production of radioisotopes with cyclotron

    International Nuclear Information System (INIS)

    Paredes G, L.; Balcazar G, M.

    1999-01-01

    The design of targets for production of radioisotopes and radiopharmaceuticals of cyclotron to medical applications requires a detailed analysis of several variables such as: cyclotron operation conditions, choice of used materials as target and their physicochemical characteristics, activity calculation, the yielding of each radioisotope by irradiation, the competition of nuclear reactions in function of the projectiles energy and the collision processes amongst others. The objective of this work is to determine the equations for the calculation for yielding of solid targets at the end of the proton irradiation. (Author)

  8. The Juelich compact cyclotron - a multi-purpose irradiation facility

    International Nuclear Information System (INIS)

    Hemmerich, J.; Hoelzle, R.; Kogler, W.

    1977-01-01

    A commercially available variable-energy compact cyclotron has been installed at the Kernforschungsanlage Juelich. It is equipped to accelerate protons, deuterons, 3 He- and α-particles. A +- 60 0 switching magnet allows to switch the beam to any of seven external target stations. Three separately shielded target rooms allow a flexible use of the cyclotron for a wide range of applications such as production of short-lived nuclides, activation analysis, radiation damage studies in metals and studies of biological effects of fast neutron irradiation. (orig.) [de

  9. Superconducting conversion of the Oak Ridge Isochronous Cyclotron

    International Nuclear Information System (INIS)

    Martin, J.A.; Ball, J.B.; Cleary, E.D.

    1981-01-01

    The superconducting conversion of the Oak Ridge Isochronous Cyclotron (ORIC) will replace the existing aluminum main magnet coils with a NbTi superconducting coil system to provide an increase in magnetic field from 1.9 to 3.3 T. The higher magnetic field will provide a three-fold increase in maximum energy capability of the cyclotron for high mass ions. The conversion will include a new beam extraction system, magnet yoke stiffening to counteract the increased magnetic forces, and minor modifications to the beam transport systems and shielding

  10. The National Medical Cyclotron - An Australian experience in technology

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, R K [Australian Nuclear Science and Technology Organisation (ANSTO), Lucas Heights, NSW (Australia). National Medical Cyclotron

    1998-12-31

    The establishment of the National Medical Cyclotron (NMC) in the early 1990`s was the practical outcome of a vision, held by nuclear medicine professionals, to complement the available neutron-rich radionuclides produced in Australia, with neutron-deficient radionuclides. The NMC is operated by the Australian Nuclear Science and Technology Organisation (ANSTO) in collaboration with the Royal Prince Alfred Hospital (RPAH) in Sydney where the PET department is able to use the short-lived radiotracers to good advantage. Neutron-deficient radionuclides, are also produced by the NMC laboratories. The cyclotron-generated radionuclides are used in over 70,000 patient studies per year. 7 refs., 1 tab.

  11. A 600 MeV cyclotron for radioactive beam production

    International Nuclear Information System (INIS)

    Clark, D.J.

    1993-01-01

    The magnetic field design for a 600 MeV proton cyclotron is described. The cyclotron has a single stage, a normal conducting magnet coil and a 9.8 m outside yoke diameter. It has 8 sectors, with a transition to 4 sectors in the center region. The magnetic field design was done using 1958 Harwell rectangular ridge system measurements and was compared with recent 3-dimensional field calculations with the program TOSCA at NSCL. The center region 4--8 sector transition focussing was also checked with TOSCA

  12. A compact cost-effective beamline for a PET Cyclotron

    International Nuclear Information System (INIS)

    Dehnel, M.P.; Jackle, P.; Roeder, M.; Stewart, T.; Theroux, J.; Brasile, J.P.; Sirot, P.; Buckley, K.R.; Bedue, M.

    2007-01-01

    Most commercial PET Cyclotrons have targets mounted on or near the main cyclotron vacuum chamber. There is often little or no system capability for centering or focusing the extracted beam on target to achieve maximum production. This paper describes the ion-optics, design and development of a compact cost-effective beamline comprised of low activation and radiation resistant materials. The beamline, complete with suitable diagnostic devices, permits the extracted proton beam to be centered (X-Y steering magnet), and focused (quadrupole doublet) on target eliminating unnecessary beamspill and ensuring high production

  13. The National Medical Cyclotron - An Australian experience in technology

    International Nuclear Information System (INIS)

    Barnes, R. K.

    1997-01-01

    The establishment of the National Medical Cyclotron (NMC) in the early 1990's was the practical outcome of a vision, held by nuclear medicine professionals, to complement the available neutron-rich radionuclides produced in Australia, with neutron-deficient radionuclides. The NMC is operated by the Australian Nuclear Science and Technology Organisation (ANSTO) in collaboration with the Royal Prince Alfred Hospital (RPAH) in Sydney where the PET department is able to use the short-lived radiotracers to good advantage. Neutron-deficient radionuclides, are also produced by the NMC laboratories. The cyclotron-generated radionuclides are used in over 70,000 patient studies per year

  14. New type sector cyclotron and improvement of EULIMA project

    International Nuclear Information System (INIS)

    Gao, Shuyang

    1988-01-01

    In this paper the two sorts of new type sector cyclotron have been discussed. Both of them remain with the same structure as straight-side sector magnet; but the annular shim systems are added on the pole faces of the every sectors. One of them has one group of the shim system; another has the three groups on the every sector. The analytical expressions of the magnetic field for the structure have been given. The linear motion stability of the particles has been proved. The new type of the compact superconducting cyclotron in the median energy is put forward as an instance for its application to the EULIMA project. (author)

  15. Polarized electron cyclotron emission in the Tokapole II Tokamak

    International Nuclear Information System (INIS)

    Sengstacke, M.A.; Dexter, R.N.; Prager, S.C.

    1984-06-01

    To examine the effect of wall reflections we have measured the polarization of second harmonic cyclotron emission (at omega = 2 omega/sub ce/) in the Tokapole II tokamak both with and without a microwave absorber installed within the field of view of the receiving antenna. Indeed, the local elimination of wall reflections markedly enhances the polarization, as described in section II. Section III describes observations consistent with right-hand cutoff effects and an attempt to infer the electron temperature from cyclotron emission in an optically thin plasma

  16. Injection and central region studies for the VINCY Cyclotron

    International Nuclear Information System (INIS)

    Milinkovic, L.; Toprek, D.; Brajuskovic, B.

    1992-01-01

    The central region of the VINCY Cyclotron, the main part of the TESLA Accelerator Installation, is designed to operate with two external ion sources: an ECR ion source for heavy ions, and a multicusp ion source for H - and D - ions. A tilted spiral inflector with an electric bending radius of 25 mm is used to bend the beams into the median plane of the Cyclotron at the magnetic radius of 16 mm. The optical properties of the inflector were studied, and an effort to minimize the inflector fringe field, using the RELAX3D code, for the calculation of the electric potential distribution, was made. (author) 7 refs.; 4 figs

  17. An overview of experiments at the Indiana University Cyclotron Facility

    International Nuclear Information System (INIS)

    Foster, C.C.

    1981-01-01

    The research program of the Indiana University Cyclotron Facility (IUCF) is a product of many factors. Among these factors are the properties of the beams of charged particles available from the cyclotrons, the facilities and personnel available to support experiments, the guidance of the Program Advisory Committee, the decisions of the directors and the ideas and work of the users of the facility. It is the author's purpose, in this brief overview paper, to provide a summary of features and properties of accelerator operation, beams, experimental facilities and the user interaction of interest to a perspective experimental user and a discussion of recent results of measurements made at IUCF

  18. On the parametric cyclotron heating of a toroidal plasma

    International Nuclear Information System (INIS)

    Golovanivsky, K.C.; Punithavelu, A.M.

    1976-01-01

    The possibility of heating the ionic component of a dense plasma at the parametric cyclotron resonance, using a section of the conducting toroidal chamber of a large scale Tokamak as a resonance cavity, is considered. It is suggested to use the mode TE 011 to overcome the difficulties with the penetration of HF fields into such a dense plasma. The experimental investigation of parametric cyclotron heating of electrons in a overdense plasma (n/nsub(cut off)=10 2 ) on such a model has given hopeful results

  19. Wave trajectory and electron cyclotron heating in tokamak plasmas

    International Nuclear Information System (INIS)

    Tanaka, S.; Maekawa, T.; Terumichi, Y.; Hamada, Y.

    1980-01-01

    Wave trajectories in high density tokamak plasmas are studied numerically. Results show that the ordinary wave injected at an appropriate incident angle can propagate into the dense plasmas and is mode-converted to the extraordinary wave at the plasma cutoff, is further converted to the electron Bernstein wave during passing a loop or a folded curve near the upper hybrid resonance layer, and is cyclotron damped away, resulting in local electron heating before arriving at the cyclotron resonance layer. Similar trajectory and damping are obtained when a microwave in a form of extraordinary wave is injected quasi-perpendicularly in the direction of decreasing toroidal field

  20. ELECTRON CYCLOTRON CURRENT DRIVE EFFICIENCY IN GENERAL TOKAMAK GEOMETRY

    International Nuclear Information System (INIS)

    LIN-LUI, Y.R; CHAN, V.S; PRATER, R.

    2003-01-01

    Green's-function techniques are used to calculate electron cyclotron current drive (ECCD) efficiency in general tokamak geometry in the low-collisionality regime. Fully relativistic electron dynamics is employed in the theoretical formulation. The high-velocity collision model is used to model Coulomb collisions and a simplified quasi-linear rf diffusion operator describes wave-particle interactions. The approximate analytic solutions which are benchmarked with a widely used ECCD model, facilitate time-dependent simulations of tokamak operational scenarios using the non-inductive current drive of electron cyclotron waves

  1. Optimization approach for saddling cost of medical cyclotrons with fuzziness

    International Nuclear Information System (INIS)

    Abass, S.A.; Massoud, E.M.A.

    2007-01-01

    Most radiation fields are combinations of different kinds of radiation. The radiations of most significance are fast neutrons, thermal neutrons, primary gammas and secondary gammas. Thermos's composite shielding materials are designed to attenuate these types of radiation. The shielding design requires an accurate cost-benefit analysis based on uncertainty optimization technique. The theory of fuzzy sets has been employed to formulate and solve the problem of cost-benefit analysis of medical cyclotron. This medical radioisotope production cyclotron is based in Sydney, Australia

  2. Cyclotron based nuclear science: Progress report, April 1, 1987-March 31, 1988

    International Nuclear Information System (INIS)

    1988-08-01

    This report discusses experiment run on the K500 cyclotron and 88 in cyclotron at Texas AandM University. The main topics of these experiments are: Heavy ion reactions; Nuclear structure and fundamental interactions; Atomic and material science; Nuclear theory; and Superconducting cyclotron and instrumentation

  3. An evaluation of patient self-testing competency of prothrombin time for managing anticoagulation: pre-randomization results of VA Cooperative Study #481--The Home INR Study (THINRS).

    Science.gov (United States)

    Dolor, Rowena J; Ruybalid, R Lynne; Uyeda, Lauren; Edson, Robert G; Phibbs, Ciaran; Vertrees, Julia E; Shih, Mei-Chiung; Jacobson, Alan K; Matchar, David B

    2010-10-01

    Prior studies suggest patient self-testing (PST) of prothrombin time (PT) can improve the quality of anticoagulation (AC) and reduce complications (e.g., bleeding and thromboembolic events). "The Home INR Study" (THINRS) compared AC management with frequent PST using a home monitoring device to high-quality AC management (HQACM) with clinic-based monitoring on major health outcomes. A key clinical and policy question is whether and which patients can successfully use such devices. We report the results of Part 1 of THINRS in which patients and caregivers were evaluated for their ability to perform PST. Study-eligible patients (n = 3643) were trained to use the home monitoring device and evaluated after 2-4 weeks for PST competency. Information about demographics, medical history, warfarin use, medications, plus measures of numeracy, literacy, cognition, dexterity, and satisfaction with AC were collected. Approximately 80% (2931 of 3643) of patients trained on PST demonstrated competency; of these, 8% (238) required caregiver assistance. Testers who were not competent to perform PST had higher numbers of practice attempts, higher cuvette wastage, and were less able to perform a fingerstick or obtain blood for the cuvette in a timely fashion. Factors associated with failure to pass PST training included increased age, previous stroke history, poor cognition, and poor manual dexterity. A majority of patients were able to perform PST. Successful home monitoring of PT with a PST device required adequate levels of cognition and manual dexterity. Training a caregiver modestly increased the proportion of patients who can perform PST.

  4. Initial field measurements on the Chalk River superconducting cyclotron

    International Nuclear Information System (INIS)

    Ormrod, J.H.; Chan, K.C.; Hill, J.H.

    1980-12-01

    The midplane magnetic field of the Chalk River superconducting cyclotron has been mapped in detail over the full operating range of 2.5 to 5 tesla. The field measuring apparatus is described and results given include measurements of the field stability, reproducibility and harmonic content. (author)

  5. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 35

    Energy Technology Data Exchange (ETDEWEB)

    1986-10-29

    Efforts are reported on the installation and checkout of cyclotron components which had been previously fabricated. Final integration of subsystems and major systems leading to internal beam tests is reported near completion. Progress is reported in relation to control system components, focus and steering magnet design, and rf system testing. (LEW)

  6. Dynamic effects on cyclotron scattering in pulsar accretion columns

    International Nuclear Information System (INIS)

    Brainerd, J.J.; Meszaros, P.

    1991-01-01

    A resonant scattering model for photon reprocessing in a pulsar accretion column is presented. The accretion column is optically thin to Thomson scattering and optically thick to resonant scattering at the cyclotron frequency. Radiation from the neutron star surface propagates freely through the column until the photon energy equals the local cyclotron frequency, at which point the radiation is scattered, much of it back toward the star. The radiation pressure in this regime is insufficient to stop the infall. Some of the scattered radiation heats the stellar surface around the base of the column, which adds a softer component to the spectrum. The partial blocking by the accretion column of X-rays from the surface produces a fan beam emission pattern. X-rays above the surface cyclotron frequency freely escape and are characterized by a pencil beam. Gravitational light bending produces a pencil beam pattern of column-scattered radiation in the antipodal direction, resulting in a strongly angle-dependent cyclotron feature. 31 refs

  7. Cyclotron targetry for production of short-lived positron emitters

    International Nuclear Information System (INIS)

    Schlyer, D.J.

    1989-01-01

    The basic concepts of cyclotron target design are presented along with the relevant practical experience gained by workers in this field over the years. Results are presented from several recent studies on the temperature and density distribution inside gas and liquid targets. 5 refs., 3 figs

  8. Computer aided operation of the Karlsruhe isochronous cyclotron using CAMAC

    International Nuclear Information System (INIS)

    Kappel, W.; Karbstein, W.; Kneis, W.; Moellenbeck, J.; Schweickert, H.; Volk, B.

    1976-01-01

    An extensive branch system is used with a NOVA 2/10 computer as an aid to the operation of the Karlsruhe Isochronous Cyclotron. The accelerator operator calls the different tasks by an interactive program system ''CICERO'' under BASIC. CAMAC operations are called by means of the ordinary BASIC Call mechanism through assembler routines

  9. Nonlinear analysis of a relativistic beam-plasma cyclotron instability

    Science.gov (United States)

    Sprangle, P.; Vlahos, L.

    1986-01-01

    A self-consistent set of nonlinear and relativistic wave-particle equations are derived for a magnetized beam-plasma system interacting with electromagnetic cyclotron waves. In particular, the high-frequency cyclotron mode interacting with a streaming and gyrating electron beam within a background plasma is considered in some detail. This interaction mode may possibly find application as a high-power source of coherent short-wavelength radiation for laboratory devices. The background plasma, although passive, plays a central role in this mechanism by modifying the dielectric properties in which the magnetized electron beam propagates. For a particular choice of the transverse beam velocity (i.e., the speed of light divided by the relativistic mass factor), the interaction frequency equals the nonrelativistic electron cyclotron frequency times the relativistic mass factor. For this choice of transverse beam velocity the detrimental effects of a longitudinal beam velocity spread is virtually removed. Power conversion efficiencies in excess of 18 percent are both analytically calculated and obtained through numerical simulations of the wave-particle equations. The quality of the electron beam, degree of energy and pitch angle spread, and its effect on the beam-plasma cyclotron instability is studied.

  10. Cyclotron targets and production technologies used for radiopharmaceuticals in NPI

    Czech Academy of Sciences Publication Activity Database

    Fišer, Miroslav; Kopička, Karel; Hradilek, Pavel; Hanč, Petr; Lebeda, Ondřej; Panek, T.; Vognar, M.

    2003-01-01

    Roč. 53, č. 2 (2003), s. A737-A743 ISSN 0011-4626 R&D Projects: GA AV ČR KSK4055109 Keywords : cyclotron * radiopharmaceuticals Subject RIV: CH - Nuclear ; Quantum Chemistry Impact factor: 0.263, year: 2003

  11. Radiation protection and safety culture for cyclotron workers

    International Nuclear Information System (INIS)

    Gomaa, M.A.

    1998-01-01

    The main aim of the present study is to review radiation protection and safety culture measures to be applied to cyclotron workers. The radiation protection (measures are based on Basic Safety standards for the protection) of the health of workers and the general public against the dangers arising from ionizing radiation, while the safety culture are based on IAEA publications

  12. On 'conflict of conservation laws in cyclotron radiation'

    International Nuclear Information System (INIS)

    DasGupta, P.

    1984-01-01

    It is shown that conservation of energy, linear momentum and angular momentum are all compatible with each other in the case of an electron undergoing cyclotron emission in a uniform and constant magnetic field. The flaw in the argument of previous workers claiming the incompatibility of the conservation principles is also pointed out. (author)

  13. Status of Chandigarh variable energy cyclotron and present experimental programmes

    International Nuclear Information System (INIS)

    Govil, I.M.

    2005-01-01

    The paper describes the status report of the Chandigarh variable energy cyclotron and some of the recent modifications which has improved the stability and performance of the machine considerably. The machine is now used for Proton Induced X-Ray Emission (PIXE) for trace element analysis along with nuclear irradiation for material science research and Nuclear Spectroscopy using (p, n γ) reaction. (author)

  14. Assessment of radionuclidic impurities in cyclotron produced Tc-99m

    Czech Academy of Sciences Publication Activity Database

    Lebeda, Ondřej; van Lier, E. J.; Štursa, Jan; Ráliš, Jan; Zyuzin, A.

    2012-01-01

    Roč. 39, č. 12 (2012), s. 1286-1291 ISSN 0969-8051 Institutional research plan: CEZ:AV0Z10480505 Keywords : Technetium-99m * cyclotron * proton irradiation * radionuclidic impurities Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 2.517, year: 2012

  15. 3D computer model of the VINCY cyclotron magnet

    International Nuclear Information System (INIS)

    Vorozhtsov, S.B.

    1996-01-01

    The VINCY Cyclotron magnetic field simulation was performed with the help of the three-dimensional (3D) software. The following aspects of the system were considered: 3D calculation of the magnetic field in the median plane, 3D calculation of the magnetic field in the extraction region, 3D calculation of the stray magnetic field. 8 refs., 17 figs., 3 tabs

  16. Radiation safety aspects of the AGOR superconducting cyclotron facility

    NARCIS (Netherlands)

    Beijers, JPM; de Meijer, RJ

    1996-01-01

    This paper describes shielding calculations and skyshine estimates for the new AGOR K=600 superconducting cyclotron facility. Both simple, semi-empirical models and Monte-Carlo simulations were used. The calculations are based on a 200 MeV proton beam incident on a trick aluminum target. Also the

  17. Magnetic phenomena in F.F.A.G. cyclotrons

    International Nuclear Information System (INIS)

    Beurtey, R.

    1957-01-01

    This study regroups and develops some experimental and theoretical results obtained with spiral tract cyclotrons. The method used has been studied previously by C. BLOCH, whom we thank for his helpful advice. We have tried to give the main useful results, which are also in accordance with the rather scarce experimental results obtained on spiral pole pieces. (author) [fr

  18. Nonlinear Cyclotron absorption of a hole doppleron in cadmium

    Energy Technology Data Exchange (ETDEWEB)

    Voloshin, I.F.; Bugal' ter, G.A.; Demikhovskii, V.Y.; Fisher, L.M.; Yudin, V.A.

    1977-10-01

    We investigated experimentally the nonlinear behavior of the impedance of a cadmium plate in the region of existence of the hole doppleron. It is shown theoretically that this phenomenon can be attributed to nonlinear cyclotron absorption of the wave in the metal. A theory of nonlinear cyclotron absorption of a hole doppleron in cadmium is constructed. The nonlinearity is due to the influence of the wave magnetic field H that alters the trajectories of the resonant electrons responsible for the cyclotron asorption. The Lorentz force connected with the field H modulates the particle velocity along the magnetic field at a characteristic frequency ..omega../sub 0/ proportional to the square root of the wave amplitude. The modulation of the longitudinal particle velocity leads to violation of the condition of their resonant interaction with the wave, as a result of which the absorption coefficient decreases. The nonlinearity is significant when the frequency ..omega../sub 0/ is large compared with the electron-collision frequency. A decrease of the cyclotron absorption changes radically the picture of the surface-impedance oscillations of the plate in the magnetic field. We studied in the experiment the influence of the temperature, of the angle of inclination of the magnetic field, and of the frequency on the nonlinear-effect threshold field that separates the regions of linear and nonlinear behavior of the sample impedance. The measurement results are in qualitative agreement with the conclusions of the theory.

  19. Cyclotron produced Tc-99m: testing compatibility with established kits

    Czech Academy of Sciences Publication Activity Database

    Lebeda, Ondřej; Ráliš, Jan; Hradilek, Pavel; Hanč, Petr; van Lier, E. J.; Zyuzin, A.; Moša, M.

    2013-01-01

    Roč. 40, 2 Supplement (2013), S424-S425 ISSN 1619-7070. [Annual Congress of the European Association of Nuclear Medicine (EANM). 19.10.2013-23.10.2013, Lyon] Institutional support: RVO:61389005 Keywords : cyclotron U-120M * Tc-99m * 100Mo Subject RIV: BG - Nuclear, Atomic and Molecular Physics , Colliders

  20. Archaeological studies on ancient coins at Bucharest cyclotron

    International Nuclear Information System (INIS)

    Bugoi, R.; Constantinescu, D.; Plostinaru, D.; Catana, D.; Sasinau, R.

    1998-01-01

    Two methods of analysis: in air PIXE and XRF were developed at the Cyclotron Laboratory in order to determine elemental composition. 50 pieces of Roman Republic (2nd Century BC) silver drachmae originating from Greek towns on the Adriatic Sea coast, founded in various regions of Romania were analysed. Considerations about some aspects of the economical policy of Roman Republic are made. (author)

  1. A new RF system for a rejuvenated Synchro-cyclotron

    CERN Multimedia

    1975-01-01

    The Synchro-cyclotron is shown here shortly after the completion of the improvement programme, which left the steel magnet yoke as almost the only remaining component of the original machine. On the left can be seen the rotary condenser which produces the frequency modulation required for the acceleration (one of a pair available -in this instance ROTCO II). (see photo 7506015)

  2. Peculiarity of the charged particles dynamics at the cyclotron resonances

    International Nuclear Information System (INIS)

    Buts, V.A.; Kuzmin, V.V.; Tolstoluzhsky, A.P.

    2016-01-01

    In this work the analysis was provided of the discrepancy between thresholds for appearance of the chaotic regime in the conditions of cyclotron resonances, obtained by analytical consideration of the particle dynamics, on the one hand, and by numerical investigation, on the other hand. The explanation is given for these threshold discrepancies.

  3. New development of neutron radiography with a small cyclotron

    International Nuclear Information System (INIS)

    Ikeda, Yasushi; Ohkubo, Kohei; Kato, Toshihiko; Nakamura, Tomihisa; Fuji, Takayoshi.

    1990-01-01

    A series of neutron radiography testing has been performed for several years by using a small accelerator called 'Baby Cyclotron' manufactured by Japan Steel Works, Ltd. The Baby Cyclotron produces fast neutrons at the rate of 4x10 12 n/cm 2 s, and enables to perform neutron radiography imaging by various techniques. The most important application of this Baby Cyclotron radiography system is the non-destructive testing (NDT) of various explosive devices prepared for space launch vehicles. It is assured that thermal neutron radiography testing is a very useful means for the NDT. Also fast neutron radiography testing is in progress. The fast neutron radiography with a CR39 track-etch image recorder was developed, and it was shown to be the very useful NDT means when the thicker objects used for new H-2 launch vehicles had to be examined. Because thermal neutron radiography has the high detectability of hydrogenous materials, organic elastomers such as O-rings and explosive powder are clearly observable through the opaque steel walls of containers. The Baby Cyclotron and the neutron radiography facility, thermal neutron and fast neutron radiography testings and so on are reported. (K.I.)

  4. Calculation of the neutrons shielding in cyclotron accelerator

    International Nuclear Information System (INIS)

    Ribeiro, Martha S.; Sanches, Matias P.; Rodrigues, Demerval L.

    2000-01-01

    The objective of radioprotection in cyclotron facilities is to reduce the dose levels in the workplaces to classify them like supervised areas. In this way, the radiation dose rates in areas occupied by workers during cyclotron operations should not exceed 7,5 μSv/h. In controlled areas these levels are not observed and some rigorous controls must be exerted by administrative procedures or protection mechanisms. The Cyclotron Laboratory at IPEN-CNEN/SP has a cyclotron model Cyclone 30, 30 MeV, used for research and it is also used for radioisotopes production for medical diagnosis and therapeutical applications. Among them, 123 I, 67 Ga and 18 F can be pointed. When accelerator is operating, failures in perforations and paths that conduce to room accelerator can be occur and thus, the dose levels are higher than that established by law. For this reason, a review for shielding structure was necessary in order to optimize radiation dose. The purpose of this work was to determine the shielding thickness and adequate material to diminish the dose rates in workplaces to a value below 7,5 μSv/h. It was used a method to employ the equivalent dose value in the facility areas for neutrons fluency rate for the principal reactions in target irradiation processes. The purposed shielding for the vault doors ensures dose levels lower than established limits to supervised areas. (author)

  5. Heavy stable isotope separation by ion cyclotron resonance

    International Nuclear Information System (INIS)

    Louvet, P.; Compant La Fontaine, A.; Larousse, B.; Patris, M.

    1994-01-01

    The scientific feasibility of the ion cyclotron resonance process (ICR), as well as the technical one, has been investigated carefully for light metallic elements, whose masses lies between 40 and 100/1,2/. The present work deals mainly with the same demonstration for heavier elements such as ytterbium, gadolinium and barium. Recent results, as well as future prospects, are considered here. (authors)

  6. Ion-Beam-Excited Electrostatic Ion Cyclotron Instability

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1977-01-01

    The stability limits of the ion‐beam‐excited, electrostatic, ion cyclotron instability were investigated in a Q‐machine plasma where the electrons could be heated by microwaves. In agreement with theory, the beam energy necessary for excitation decreased with increasing electron temperature....

  7. Ion-Beam-Excited, Electrostatic, Ion Cyclotron Instability

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1977-01-01

    The stability limits of the ion‐beam‐excited, electrostatic, ion cyclotron instability were investigated in a Q‐machine plasma where the electrons could be heated by microwaves. In agreement with theory, the beam energy necessary for excitation decreased with increasing electron temperature....

  8. Ion cyclotron resonance heating in the Wisconsin supported toroidal octupole

    International Nuclear Information System (INIS)

    Barter, J.D.; Sprott, J.C.

    1977-01-01

    Ion heating at the fundamental of the cyclotron resonance (1 MHz 12 cm -3 ) with no evidence of parametric decay or enhanced particle loss other than temperature dependent losses such as thermal flow to obstacles. Ion temperatures are limited by charge exchange on the large neutral reflux at the higher rf powers. (author)

  9. Plasma particle drifts due to traveling waves with cyclotron frequencies

    International Nuclear Information System (INIS)

    Hatakeyama, Rikizo; Sato, Naoyuki; Sato, Noriyoshi

    1991-01-01

    A particle orbit theory yields that traveling waves with cyclotron frequencies give rise to charged particle drifts perpendicular both to the wave propagation and external magnetic field lines. The result is applicable to particle-flux control of magnetized plasmas. (author)

  10. Operation of the Karlsruhe Isochronous Cyclotron in 1976

    International Nuclear Information System (INIS)

    Schulz, F.; Schweickert, H.

    1977-08-01

    The operation of the Karlsruhe Isochronous Cyclotron in 1976 is briefly surveyed. The status and the results of the following technical developments are briefly described: 1) Computer aided cyclotron operation; 2) New correction coils for the cyclotron; 3) Non-intercepting measurement of the extraction rate; 4) Lambshift source for polarized deuterons; 5) Improvements of the 6 Li 3+ -Penning ion source; 6) New beam line to an irradiation room for machine parts; 7) Nova 2 computer system for nuclear physics experiments; 8) Routine production of Iodine-123 for nuclear medicine. - In the annual report 1975 we have included a section consisting of a series of brief reports on applied research in progress. This year we give a compilation of the current basic nuclear physics work at our cyclotron. The short papers prepared by the experimental groups are arranged according to the following topics: 1) Experiments using the 156 MeV 6 Li 3+ -beam; 2) Experiments using the 52 MeV polarized deuteron beam; 3) Further nuclear reactions; 4) Nuclear spectroscopy; 5) Measurements of nuclear magnetic moments; 6) Measurements with the neutron time-of-flight spectrometer. (orig.) [de

  11. Digital control in LLRF system for CYCIAE-100 cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Zhiguo, E-mail: bitbearAT@hotmail.com; Fu, Xiaoliang; Ji, Bin; Zhang, Tianjue; Wang, Chuan

    2016-05-21

    As a driven accelerator, the CYCIAE-100 cyclotron is designed by China Institute of Atomic Energy for the Beijing Radio Ion-beam Facility project. The cyclotron RF system is designed to use two RF power sources of 100 kW to drive two half-wavelength cavities respectively. Two Dee accelerating electrodes are kept separately from each other inside the cyclotron, while their accelerating voltages are maintained in phase by the efforts of LLRF control. An analog–digital hybrid LLRF system has been developed to achieve cavity tuning control, dee voltage amplitude and phase stabilization etc. The analog subsystems designs are focused on RF signal up/down conversion, tuning control, and dee voltage regulation. The digital system provides an RF signal source, aligns the cavity phases and maintains a Finite State Machine. The digital parts combine with the analog functions to provide the LLRF control. A brief system hardware introduction will be given in this paper, followed by the review of several major characteristics of the digital control in the 100 MeV cyclotron LLRF system. The commissioning is also introduced, and most of the optimization during the process was done by changing the digital parts.

  12. Radiation safety and quality control in the cyclotron laboratory

    International Nuclear Information System (INIS)

    Sharma, S.; Krause, G.; Ebadi, M.

    2006-01-01

    Radiation safety was determined to maintain quality control in the cyclotron laboratory. Based on the results of 438 runs in the Faraday cup (20 μA for 10 min), 20 runs on 18 O-water target (40 μA for 2 h) and 10 runs on 18 O-gas targets (30 μA for 45 min), we have established that occupationally exposed workers remain 10 ± 5 times below federal regulatory limits (FRLs) in the cyclotron vault, 30 ± 8 times below FRL in the radiochemistry laboratory and 200 ± 10 times below the FRL outside the cyclotron laboratory during beam operation. (The FRL for unrestricted area are <20 μSv in 1 h.) The non-occupationally exposed workers serving in offices in the vicinity of the cyclotron vault within 100 m distance remained 200 times below the FRL irrespective of beam being on or off, suggesting that routine beam operation of 40 μA for 2 h once a day during office hours is safe provided quality control and system performance measures as discussed in this report are strictly maintained. (authors)

  13. Remote machining and robotic welding in a proton cyclotron

    International Nuclear Information System (INIS)

    Cameron, W.; Mark, C.

    1984-01-01

    Increasing residual radiation in the TRIUMF meson research facility cyclotron at the University of British Columbia has required development of a remotely operable industrial robot cutting and vacuum tight welding capability for modification and updating of vacuum tank access ports, and for possible repairs of leaks or holes in the vacuum tank periphery

  14. Isotope separation in plasma by ion-cyclotron resonance method

    International Nuclear Information System (INIS)

    Dubinov, A.E.; Kornilova, I.Yu.; Selemir, V.D.

    2001-01-01

    Contemporary state of investigation on isotope separation in plasma using selective ion-cyclotron resonance (ICR) heating is considered. The main attention is paid to necessary conditions of heating selectivity, plasma creation methods in isotope ICR-separation facilities, selection of antenna systems for heating, and principles of more-heated component selection. Experimental results obtained at different isotope mixtures separation are presented [ru

  15. Electron-cyclotron-resonant-heated electron distribution functions

    International Nuclear Information System (INIS)

    Matsuda, Y.; Nevins, W.M.; Cohen, R.H.

    1981-01-01

    Recent studies at Lawrence Livermore National Laboratory (LLNL) with a bounce-averaged Fokker-Planck code indicate that the energetic electron tail formed by electron-cyclotron resonant heating (ECRH) at the second harmonic is not Maxwellian. We present the results of our bounce-averaged Fokker-Planck code along with some simple analytic models of hot-electron distribution functions

  16. Development of beam instruments at JAERI cyclotron facility

    Energy Technology Data Exchange (ETDEWEB)

    Okumura, Susumu; Fukuda, Mitsuhiro; Ishibori, Ikuo; Agematsu, Takashi; Yokota, Watalu; Nara, Takayuki; Nakamura, Yoshiteru; Arakawa, Kazuo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    A beam phase monitor and two kinds of fluence distribution monitors have been developed for measuring characteristics of cyclotron beams. The beam phase monitor provides a beam phase signal for tuning a beam chopping system and a beam phase selection system. A two-dimensional fluence distribution on a large area is measured with fluence distribution monitors. (author)

  17. The development of technology for the improvement of cyclotron performance

    Energy Technology Data Exchange (ETDEWEB)

    Chai, Jong Seo; Kim, Y. S.; Ha, J. H.; Lee, M. Y.; Lee, H. S

    1999-05-01

    We show the first-order beam optics theory which is a simplified theory that can be used to carry out the initial design of a cyclotron. Based on this, a computer program has been developed to determine main cyclotron parameters such as number of magnet sectors, sector angle, hill and valley fields, and overall size of the cyclotron etc. We then show the result of two-dimensional magnetic field calculation using POISSON program. By using this program, one can determine magnet yoke geometry and the average magnetic fields etc. Finally, the three-dimensional computer program OPERA-3D had been invoked to determine magnet pole tips (i.e. sector). Validity of the design can be seen by investigating magnetic fields, radial and vertical focusing frequencies as a function of the beam energy. In this report, we show the results of cyclotron magnet design. And we designed 72 MHz RF system and ion source system. We tested RF resonance each coupling methods. We show the result of RF design and prototype operation. Our developed ion source is PIG type. We described our design methods and implementation. We report the result of getting negative hydrogen ion.

  18. Computational tools for cyclotron design, commissioning, and operation

    International Nuclear Information System (INIS)

    Kost, C.J.

    1989-05-01

    Many support systems are required in the design, commissioning, and normal operation of a modern cyclotron. Presented is an overview of the computing environment developed during these various stages at TRIUMF. The current computing environment is also discussed, with emphasis on how one can provide an integrated system which is user-friendly

  19. New irradiation facilities at the Australian national medical cyclotron

    International Nuclear Information System (INIS)

    Parcell, S.K.; Arnott, D.W.; Conard, E.M.

    1999-01-01

    Two new irradiation facilities have been developed at the National Medical Cyclotron for radionuclide production. The first relocates PET irradiations from the cyclotron vault to a dedicated PET beam room, to improve accessibility and reduce radiation exposures associated with target maintenance. This new facility consists of a beam line to transport 16-30 MeV proton beams from the cyclotron to 1 of 8 PET targets mounted on a target rack. The target rack has increased the number of targets available for production and experimentation. The second is a completely independent solid target irradiation facility for SPECT. This facility consists of a beam line to transport 26-30 MeV proton beams from the cyclotron to a dedicated beam room containing one solid target station. A new pneumatic target transfer system was also developed to transport the solid target to and from the existing chemistry hot cells. The beam line and target components are operated under the control of a dedicated PLC with a PC based user interface. The development and some technical aspects of these new irradiation facilities are discussed here. (author)

  20. Operational experience and recent developments at the National Medical Cyclotron

    International Nuclear Information System (INIS)

    Conard, E.; Pac, B.; Arnott, D.W.

    1994-01-01

    The National Medical Cyclotron is a radioisotope production facility run by ANSTO and located on the grounds of the Royal Prince Alfred Hospital in Sydney, Australia. A CYCLONE 30 (IBA) cyclotron is used in the production of short-lived PET radiopharmaceuticals required by the hospital's PET Scanner and also to produce a number of bulk radiochemicals for processing and distribution throughout Australasia. Following commissioning of the cyclotron and beam lines in October 1991, and the overcoming of a number of early open-quote teething close-quote problems especially relating to the reliability of the r.f. and solid target transport systems, a steady program of improvements has been pursued. These improvements have included development of new beam diagnostics and the design and installation of a new beam line for SPECT radioisotope production. The current operations schedule includes the production of 18 FDG, 13 NH 3 , 15 O 2 and 201 Tl, 67 Ga and 123 I. This paper will discuss the process of development of the cyclotron to ably meet the present demands on it, and the problems resolved in the pursuit of this goal

  1. 40. anniversary of cyclotron of Institute of Nuclear Physics, Tashkent

    International Nuclear Information System (INIS)

    Umerov, R.A.; Uzakov, J.M.; Gulamov, I.R.

    2004-01-01

    Full text: The Cyclotron U-150-II of Institute of Nuclear Physics was projected in middle of the last century for nuclear-physical researches in a scientific research institute of electro physical equipment in Leningrad. The Cyclotron can accelerate positive ions with beam energy of the protons 18 MeV, deuterons 20 MeV, alpha particles 40 MeV. Intensity of a beam a little some microampere. The building of a Cyclotron represents an impressive three-floor construction in volume of 2000 m 3 . The capital equipment, the high-frequency generator, sources of power supplies, vacuum pumps and other technological units are placed on the first and socle floors of a building. The second and third floors served for accommodation of scientific laboratories. A building of a Cyclotron has three experimental halls, where it was possible to carry out physical researches. They have divided from each other, and the main thing from the accelerator, concrete walls with the purpose of reduction of the big radiating background at the working accelerator, preventing realization of experiments. It provided also biological protection of the on duty personnel. The first some years of operation of the Cyclotron have revealed a line of lacks of this machine. For example, for change of energy of a beam of a Cyclotron it took 2-3 weeks. Also, for transition of acceleration of one particles to others it take same time. Time parameters of a beam were unstable. In 1968 reconstruction of the Cyclotron has been started that has allowed to bring in basic changes to parameters U-150-II. The time took on change of an operating mode of a Cyclotron was sharply reduced, and it was possible to reduce it till 10-20 hours, to improve the energy and time resolution of a beam many times over, to reduce angular straggling of particles in a beam. And, all this enormous amount of works was spent by forces of institute. In 70 th years the big development was received with works on radiating stability of materials

  2. Radiation technologies at INR NASU

    International Nuclear Information System (INIS)

    Vishnevs'kij, Yi.M.; Sakhno, V.Yi.; Tomchaj, S.P.

    2011-01-01

    The results of Institute for Nuclear Research of National Academy of Sciences of Ukraine in the development and use of nuclear and radiation technologies applied for a number of scientific, technical and technological projects in the framework of state budget themes, research programs, innovation and scientific and technological national and international programs and projects are presented.

  3. Use of cyclotrons in medical research: Past, present, future

    Science.gov (United States)

    Smathers, James B.; Myers, Lee T.

    1985-05-01

    The use of cyclotrons in medical research started in the late 1930s with the most prominent use being neutron irradiation in cancer therapy. Due to a lack of understanding of the biological effect of neutrons, the results were less than encouraging. In the 1940s and 1950s, small cyclotrons were used for isotope production and in the mid 60s, the biological effect of neutrons was more thoroughly studied, with the result that a second trial of neutron therapy was initiated at Hammersmith Hospital, England. Concurrent with this, work on the use of high energy charged particles, initially protons and alphas, was initiated in Sweden and Russia and at Harvard and Berkeley. The English success in neutron therapy led to some pilot studies in the USA using physics cyclotrons of various energies and targets. These results in turn lead to the present series of machines presently being installed at M.D. Anderson Hospital (42 MeV), Seattle (50 MeV) and UCLA (46 MeV). The future probably bodes well for cyclotrons at the two extremes of the energy range. For nuclear medicine the shift is away from the use of multiple isotopes, which requires a large range of particles and energies to 11C, 13N, 15O, and 18F, which can be incorporated in metabolic specific compounds and be made with small 8-10 MeV p+ "table top" cyclotrons. For tumor therapy machines of 60 MeV or so will probably be the choice for the future, as they allow the treatment of deep seated tumors with neutrons and the charged particles have sufficient range to allow the treatment of ocular tumors.

  4. A new slow positron beam facility using a compact cyclotron

    International Nuclear Information System (INIS)

    Hirose, Masafumi

    1998-01-01

    In 1993, Sumitomo Heavy Industries became the first in the world to successfully produce a slow positron beam using a compact cyclotron. Slow positron beam production using an accelerator had mainly consisted of using an electron linear accelerator (LINAC). However, the newly developed system that uses a compact cyclotron enabled cost reduction, downsizing of equipment, production of a DC slow positron beam, a polarized slow positron beam, and other benefits. After that, a genuine slow positron beam facility was developed with the construction of compact cyclotron No.2, and beam production in the new facility has already been started. The features of this new slow positron beam facility are explained below. 1) It is the world's first compact slow positron beam facility using a compact cyclotron. 2) It is the only genuine slow positron beam facility in the world which incorporates the production and use of a slow positron beam in the design stage of the cyclotron. To use a slow positron beam for non-destructive detection of lattice defects in semiconductor material, it is necessary to convert the beam into ultra-short pulses of several hundreds of pico-seconds. Sumitomo Heavy Industries has devised a new short-pulsing method (i.e. an induction bunching method) that enables the conversion of a slow positron beam into short pulses with an optimum pulsing electric field change, and succeeded in converting a slow positron beam into short pulses using this method for the first time in the world. Non-destructive detection of lattice defects in semiconductor material using this equipment has already been started, and some information about the depth distribution, size, density, etc. of lattice defects has already been obtained. (J.P.N.)

  5. Standardized high current solid targets for cyclotron production of radionuclides

    International Nuclear Information System (INIS)

    Al-Jammaz, Ibrahim

    2000-01-01

    The Cyclotron and Radiopharmaceuticals Department (CRP) is an advanced and modern facility that encompasses two essential components: radioisotope research, and radiopharmaceuticals manufacturing. Radiopharmaceuticals manufacturing program is not only quite unique, but also an essential component of King Faisal Specialist Hospital and Research Center (KFSH and RC) in providing quality patient care for the population of the Kingdom. Accurate diagnosis and therapy with medical imaging equipment requires quality radiopharmaceuticals that are available readily and with reliability. The CRP Department provides that quality and reliability. Research activities of the CRP Department are focused on developing new radiotracers with potential usefulness in biomedical research and clinical applications. Research projects consist of: developing cyclotron targetry for radioisotope production; developing synthesis methods for radiolabeling biomolecules; and developing analytical methods for quality control. The CRP Department operates a semi-commercial radiopharmaceuticals manufacturing program that supplies the diagnostic radioactive products to several hospitals in the Kingdom and neighboring countries. These products for clinical applications are produced according to the international standards of Good Manufacturing Practices of quality and efficacy. At the heart of the radioisotope program is a medium energy cyclotron capable of accelerating a number of particles for transformation of non-radioactive atoms into radionuclides that are the primary sources for research and development activities, and for preparing radiopharmaceuticals. In addition to having the only cyclotron facility in the region, KFSH and RC also has the only Positron Emission Tomography Center (PET) in this part of the world. This combination of cyclotron and the ultra modern PET facility translates into advanced and specialized care for the patients at KFSH and RC

  6. Study of the cyclotron operating conditions; Etude des conditions de fonctionnement du cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Debraine, P; Bariaud, A; Goldschmidt-Clermont, Y

    1948-12-01

    This work is a detailed study of the operating conditions of the cyclotron. It analyzes the behaviour of the particles from their first accelerations to their arrival on an external target. Calculations were performed using relativistic formulations in order to make the results usable without any energy level restriction. The obtained results supply some numerical elements for a cyclotron pre-determination and allow a satisfactory visualization of the real phenomena taking place during the accelerations. The shape of the phase change during the successive accelerations has been obtained for a given magnetic field configuration with respect to the operating frequency, to the magnetic field value in the center, and to the accelerating voltage between the dees. Taking into account the limitations due to the accelerating and focussing conditions, the usable phase interval has been determined with respect to the characteristic operating parameters. The study of this phase interval with respect to the accelerating voltage, on the one hand, and with respect to the frequency or to the center magnetic field, on the other hand, has permitted to find again two facts experimentally observed: voltage threshold and dissymmetry of the response curve. The study of radial and axial oscillations has shown the existence of precession phenomena and indicates a maximum limit for the magnetic field variation in order to avoid the disturbances due to oscillations coupling. The study of the ion beam envelope inside the chamber with respect to the initial phases has permitted to determine the optimum shape of the dees and the height of the deflecting channel. Moreover, the influence of various parameters on the ion beam efficiency can be shown using an ideal source. The study of the passing conditions inside the deflecting channel has shown the influence of the separation sheet, has given the dimensions to foresee for the deflecting channel, and has indicated the way to follow to obtain

  7. Cyclotron Phase-Coherent Ion Spatial Dispersion in a Non-Quadratic Trapping Potential is Responsible for FT-ICR MS at the Cyclotron Frequency

    Science.gov (United States)

    Nagornov, Konstantin O.; Kozhinov, Anton N.; Tsybin, Yury O.

    2018-01-01

    Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) at the cyclotron frequency instead of the reduced cyclotron frequency has been experimentally demonstrated using narrow aperture detection electrode (NADEL) ICR cells. Here, based on the results of SIMION simulations, we provide the initial mechanistic insights into the cyclotron frequency regime generation in FT-ICR MS. The reason for cyclotron frequency regime is found to be a new type of a collective motion of ions with a certain dispersion in the initial characteristics, such as pre-excitation ion velocities, in a highly non-quadratic trapping potential as realized in NADEL ICR cells. During ion detection, ions of the same m/z move in phase for cyclotron ion motion but out of phase for magnetron (drift) ion motion destroying signals at the fundamental and high order harmonics that comprise reduced cyclotron frequency components. After an initial magnetron motion period, ion clouds distribute into a novel type of structures - ion slabs, elliptical cylinders, or star-like structures. These structures rotate at the Larmor (half-cyclotron) frequency on a plane orthogonal to the magnetic field, inducing signals at the true cyclotron frequency on each of the narrow aperture detection electrodes. To eliminate the reduced cyclotron frequency peak upon dipolar ion detection, a number of slabs or elliptical cylinders organizing a star-like configuration are formed. In a NADEL ICR cell with quadrupolar ion detection, a single slab or an elliptical cylinder is sufficient to minimize the intensity of the reduced cyclotron frequency components, particularly the second harmonic. [Figure not available: see fulltext.

  8. Decontamination of the activation product based on a legal revision of the cyclotron vault room on the non-self-shield compact medical cyclotron

    International Nuclear Information System (INIS)

    Komiya, Isao; Umezu, Yoshiyuki; Fujibuchi, Toshiou; Nakamura, Kazumasa; Baba, Shingo; Honda, Hiroshi

    2016-01-01

    The non-self-shield compact medical cyclotron and the cyclotron vault room were in operation for 27 years. They have now been decommissioned. We efficiently implemented a technique to identify an activation product in the cyclotron vault room. Firstly, the distribution of radioactive concentrations in the concrete of the cyclotron vault room was estimated by calculation from the record of the cyclotron operation. Secondly, the comparison of calculated results with an actual measurement was performed using a NaI scintillation survey meter and a high-purity germanium detector. The calculated values were overestimated as compared to the values measured using the Nal scintillation survey meter and the high-purity germanium detector. However, it could limit the decontamination area. By simulating the activation range, we were able to minimize the concrete core sampling. Finally, the appropriate range of radioactivated area in the cyclotron vault room was decontaminated based on the results of the calculation. After decontamination, the radioactive concentration was below the detection limit value in all areas inside the cyclotron vault room. By these procedures, the decommissioning process of the cyclotron vault room was more efficiently performed. (author)

  9. Summary of EC-17: the 17th Joint Workshop on Electron Cyclotron Emission and Electron Cyclotron Resonance Heating (Deurne, The Netherlands, 7-10 May 2012)

    NARCIS (Netherlands)

    Westerhof, E.; Austin, M. E.; Kubo, S.; Lin-Liu, Y. R.; Plaum, B.

    2013-01-01

    An overview is given of the papers presented at the 17th Joint Workshop on Electron Cyclotron Emission (ECE) and Electron Cyclotron Resonance Heating (ECRH). The meeting covered all aspects of the research field ranging from theory to enabling technologies. From the workshop, advanced control by

  10. Aharonov-Bohm effect in cyclotron and synchrotron radiations

    Energy Technology Data Exchange (ETDEWEB)

    Bagrov, V.G.; Gitman, D.M. E-mail: gitman@fma.if.usp.br; Levin, A.; Tlyachev, V.B

    2001-07-02

    We study the impact of Aharonov-Bohm solenoid on the radiation of a charged particle moving in a constant uniform magnetic field. With this aim in view, exact solutions of Klein-Gordon and Dirac equations are found in the magnetic-solenoid field. Using such solutions, we calculate exactly all the characteristics of one-photon spontaneous radiation both for spinless and spinning particle. Considering non-relativistic and relativistic approximations, we analyze cyclotron and synchrotron radiations in detail. Radiation peculiarities caused by the presence of the solenoid may be considered as a manifestation of Aharonov-Bohm effect in the radiation. In particular, it is shown that new spectral lines appear in the radiation spectrum. Due to angular distribution peculiarities of the radiation intensity, these lines can in principle be isolated from basic cyclotron and synchrotron radiation spectra.

  11. Aharonov-Bohm effect in cyclotron and synchrotron radiations

    International Nuclear Information System (INIS)

    Bagrov, V.G.; Gitman, D.M.; Levin, A.; Tlyachev, V.B.

    2001-01-01

    We study the impact of Aharonov-Bohm solenoid on the radiation of a charged particle moving in a constant uniform magnetic field. With this aim in view, exact solutions of Klein-Gordon and Dirac equations are found in the magnetic-solenoid field. Using such solutions, we calculate exactly all the characteristics of one-photon spontaneous radiation both for spinless and spinning particle. Considering non-relativistic and relativistic approximations, we analyze cyclotron and synchrotron radiations in detail. Radiation peculiarities caused by the presence of the solenoid may be considered as a manifestation of Aharonov-Bohm effect in the radiation. In particular, it is shown that new spectral lines appear in the radiation spectrum. Due to angular distribution peculiarities of the radiation intensity, these lines can in principle be isolated from basic cyclotron and synchrotron radiation spectra

  12. Examination of the plasma located in PSI Ring Cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Pogue, N.J., E-mail: nathaniel.pogue@psi.ch; Adelmann, A.; Schneider, M.; Stingelin, L.

    2016-06-11

    A plasma has been observed inside the vacuum chamber of the PSI Ring Cyclotron. This ionized gas cloud may be a substantial contributor to several interior components having reduced lifetimes. The plasma's generation has been directly linked to the voltage that is applied to the Flat Top cavity through visual confirmation using CCD cameras. A spectrometer was used to correlate the plasma's intensity and ignition to the Flat Top cavity voltage as well as to determine the composition of the plasma. This paper reports on the analysis of the plasma using spectroscopy. The spectrometer data was analyzed to determine the composition of the plasma and that the plasma intensity (luminosity) directly corresponds to the Flat Top voltage. The results show that the plasma is comprised of elements consistent with the cyclotrons vacuum interior.

  13. First years of operation of the LNS superconducting cyclotron

    International Nuclear Information System (INIS)

    Rifuggiato, D.; Calabretta, L.; Cuttone, G.; Gammino, S.; Raia, G.; Rovelli, A.

    1999-01-01

    The K800 Superconducting Cyclotron was commissioned in 1994 and has been in continuous operation since then. In 1996 many efforts were made to reach a condition of reliable operation. Several ion types have been accelerated and delivered to experimental halls. The demand for different beams has given the opportunity to explore several regions of the operating diagram of the machine: different magnetic field values have been set, as well as several RF frequencies have been used. The results demonstrate that the Cyclotron allows to accomplish a large variety of nuclear physics experiments, even if the maximum performance has not yet been achieved. A few sub-systems are being upgraded in view of the 'high intensity' operation (which is required for radioactive beam production) and in order to reach the maximum performance: upgrading is planned on the RF system and on the electrostatic deflectors. A new axial injection system has been designed to operate the machine in stand-alone mode. (authors)

  14. Interpretation of ion cyclotron emission from fusion and space plasmas

    International Nuclear Information System (INIS)

    Dendy, R.O.

    1994-01-01

    Superthermal ion cyclotron emission (ICE) is observed in both fusion and space plasma. Typical spectra display strong peaks at sequential multiple ion cyclotron harmonics, and distinct energetic ion populations are present in the emitting regions. In JET and TFTR, for example, ICE appears to be driven by fusion products or by injected beam ions in the outer mid plane; and in the Earth's ring current, radiation belts, and bow shock, ICE has been observed by the spacecraft OGO 3, GEOS 1 and 2 and AMPTE/IRM, often in conjunction with highly non-Maxwellian proton populations. Common emission mechanisms, arising from collective relaxation of energetic ion populations, appear to operate in both the fusion and space plasma environments. These are reviewed here, and the potential role of ICE as a diagnostic of energetic ion populations is also examined. (Author)

  15. Effect of hot α-particles on ion cyclotron absorption

    International Nuclear Information System (INIS)

    Cairns, R.A.; Kay, A.; Lashmore-Davies, C.N.

    1987-01-01

    Ion cyclotron heating involves mode conversion of the incident fast wave to a Bernstein mode, which is generally stongly damped and only propagates in a localized region of the plasma. The usual theoretical approach to this problem involves solution of fourth or higher order equations, but by treating the Bernstein mode as a driven response to the fast wave we obtain a simple second order equation. Comparison of its solutions with those of higher order equations shows that this approach gives good results. The same method can be used to consider the effect of a small population of hot α-particles on ion cyclotron heating, since it does away with the need for a small larmor radius expansion. The results indicate that a small concentration of α-particles can absorb a substantial fraction of the incident energy

  16. A CCD camera probe for a superconducting cyclotron

    International Nuclear Information System (INIS)

    Marti, F.; Blue, R.; Kuchar, J.; Nolen, J.A.; Sherrill, B.; Yurkon, J.

    1991-01-01

    The traditional internal beam probes in cyclotrons have consisted of a differential element, a wire or thin strip, and a main probe with several fingers to determine the vertical distribution of the beam. The resolution of these probes is limited, especially in the vertical direction. The authors have developed a probe for their K1200 superconducting cyclotron based on a CCD TV camera that works in a 6 T magnetic field. The camera looks at the beam spot on a scintillating screen. The TV image is processed by a frame grabber that digitizes and displays the image in pseudocolor in real time. This probe has much better resolution than traditional probes. They can see beams with total currents as low as 0.1 pA, with position resolution of about 0.05 mm

  17. A beam energy measurement system at NIRS-930 cyclotron

    International Nuclear Information System (INIS)

    Hojo, S.; Honma, T.; Sakamoto, Y.; Miyahara, N.; Okada, T.; Komatsu, K.; Tsuji, N.; Yamada, S.

    2005-01-01

    A beam energy measurement system employing a set of capacitive probes has been developed at NIRS-930 cyclotron. Principle of the measurement is applying a modified-TOF method, so that the two proves are installed at one of the straight section in the beam transport line. Usually they are separated about 5.8 m, which is equivalent to the almost final path length of the beam extracted in the cyclotron. In the measurement, two beam signals are superimposed by adjusting a position of the downstream-probe along the beam direction with watching an oscilloscope screen roughly. In order to determine the beam energy accurately the signals are processed by MCA with suitable electric module. (author)

  18. Electron cyclotron current drive efficiency in an axisymmetric tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez-Tapia, C.; Beltran-Plata, M. [Instituto Nacional de Investigaciones Nucleares, Dept. de Fisica, Mexico D.F. (Mexico)

    2004-07-01

    The neoclassical transport theory is applied to calculate electron cyclotron current drive (ECCD) efficiency in an axisymmetric tokamak in the low-collisionality regime. The tokamak ordering is used to obtain a system of equations that describe the dynamics of the plasma where the nonlinear ponderomotive (PM) force due to high-power radio-frequency (RF) waves is included. The PM force is produced around an electron cyclotron resonant surface at a specific poloidal location. The ECCD efficiency is analyzed in the cases of first and second harmonics (for different impinging angles of the RF waves) and it is validated using experimental parameter values from TCV and T-10 tokamaks. The results are in agreement with those obtained by means of Green's function techniques. (authors)

  19. Micro computer aided beam transport for the SF cyclotron

    International Nuclear Information System (INIS)

    Honma, Toshihiro; Yamazaki, Tsutomu.

    1984-01-01

    An improvement of the beam transport system for the SF cyclotron is described. The system was designed to handle on-line alignment of the beam extracted from the SF cyclotron onto the optical axis of the transport line. It also enables to measure the beam emittance. The measurement of the emittance parameters is in particular necessary to calculate the beam optics. The calculation has been modified to become easy to handle. With the help of the computer-aided on-line beam profile measurement system, the operation of the beam transport system is very subservient to shorten the beam-tuning time and to improve the beam-transmission efficiency and the quality. (author)

  20. Cyclotron resonance for electrons over helium in resonator

    CERN Document Server

    Shikin, V B

    2002-01-01

    The problem on the cyclotron resonance (CR) for electrons on the helium film, positioned in the resonator lower part, is solved. It is shown, that it relates to one of the examples of the known problem on the oscillations of the coupled oscillators system. The coupling constant between these oscillators constituting the variable function of the problem parameters. It is minimal in the zero magnetic field and reaches its maximum under the resonance conditions, when the cyclotron frequency coincides with one of the resonator modes. The CR details of the Uhf CR-energy absorption coupled by the electrons + resonator system, are calculated. The applications of the obtained results to the available CR experiments for electrons over helium

  1. Cyclotron spectra from inhomogeneous accretion columns. II. Polarization

    International Nuclear Information System (INIS)

    Wu, K.; Chanmugam, G.

    1989-01-01

    Circularly and linearly polarized radiation from inhomogeneous cyclotron emission regions with uniform magnetic field and temperature but different electron density profiles are studied. Calculations show that the inhomogeneous models generally produce larger polarization for low harmonics and smaller polarization for high harmonics compared to the homogeneous models. Polarization light curves for different inhomogeneous models with a wide variety of parameters are presented, providing handy theoretical results to compare with observations. The observed polarization light curves of ST LMi, EF Eri, and BL Hydri are fitted using an inhomogeneous model for the first time, and good fits are obtained, supporting the hypothesis that the cyclotron emission regions of AM Her systems have a complicated structure. 37 refs

  2. PHYSICS OF ELECTRON CYCLOTRON CURRENT DRIVE ON DIII-D

    International Nuclear Information System (INIS)

    PETTY, C.C.; PRATER, R.; LUCE, T.C.; ELLIS, R.A.; HARVEY, R.W.; KINSEY, J.E.; LAO, L.L.; LOHR, J.; MAKOWSKI, M.A.

    2002-01-01

    OAK A271 PHYSICS OF ELECTRON CYCLOTRON CURRENT DRIVE ON DIII-D. Recent experiments on the DIII-D tokamak have focused on determining the effect of trapped particles on the electron cyclotron current drive (ECCD) efficiency. The measured ECCD efficiency increases as the deposition location is moved towards the inboard midplane or towards smaller minor radius for both co and counter injection. The measured ECCD efficiency also increases with increasing electron density and/or temperature. The experimental ECCD is compared to both the linear theory (Toray-GA) as well as a quasilinear Fokker-Planck model (CQL3D). The experimental ECCD is found to be in better agreement with the more complete Fokker-Planck calculation, especially for cases of high rf power density and/or loop voltage

  3. Transparency of magnetized plasma at the cyclotron frequency

    International Nuclear Information System (INIS)

    Shvets, G.; Wurtele, J.S.

    2002-01-01

    Electromagnetic radiation is strongly absorbed by a magnetized plasma if the radiation frequency equals the cyclotron frequency of plasma electrons. It is demonstrated that absorption can be completely canceled in the presence of a magnetostatic field of an undulator, or a second radiation beam, resulting in plasma transparency at the cyclotron frequency. This effect is reminiscent of the electromagnetically induced transparency (EIT) of three-level atomic systems, except that it occurs in a completely classical plasma. Unlike the atomic systems, where all the excited levels required for EIT exist in each atom, this classical EIT requires the excitation of nonlocal plasma oscillation. A Lagrangian description was used to elucidate the physics of the plasma transparency and control of group and phase velocity. This control leads to applications for electromagnetic pulse compression and electron/ion acceleration

  4. Remote target removal for the Oak Ridge 86-inch Cyclotron

    International Nuclear Information System (INIS)

    Walls, A.A.

    1982-01-01

    A remotely operated target remover has been plaed in operation at the 86-Inch Cyclotron located in Oak Ridge. The system provides for the remote removal of a target from inside the cyclotron, loading it into a cask, and the removal of the cask from the 1.5 m (5-ft) shielding walls. The remote system consists of multiple electrical and pneumatically operated equipment which is designed for controlled step-by-step operation, operated with an electrical control panel, and monitored by a television system. The target remover has reduced the radiation exposures to operating personnel at the facility and has increased the effective operating time. The system is fast, requires a minimum of skill to operate, and has demonstrated both reliability and durability

  5. Permanent magnet electron cyclotron resonance plasma source with remote window

    International Nuclear Information System (INIS)

    Berry, L.A.; Gorbatkin, S.M.

    1995-01-01

    An electron cyclotron resonance (ECR) plasma has been used in conjunction with a solid metal sputter target for Cu deposition over 200 mm diameters. The goal is to develop a deposition system and process suitable for filling submicron, high-aspect ratio ULSI features. The system uses a permanent magnet for creation of the magnetic field necessary for ECR, and is significantly more compact than systems equipped with electromagnets. A custom launcher design allows remote microwave injection with the microwave entrance window shielded from the copper flux. When microwaves are introduced at an angle with respect to the plasma, high electron densities can be produced with a plasma frequency significantly greater than the electron cyclotron frequency. Copper deposition rates of 1000 A/min have been achieved

  6. Introduction to ECR [electron cyclotron resonance] sources in electrostatic machines

    International Nuclear Information System (INIS)

    Olsen, D.K.

    1989-01-01

    Electron Cyclotron Resonance (ECR) ion source technology has developed rapidly since the original pioneering work of R. Geller and his group at Grenoble in the early 1970s. These ion sources are capable of producing intense beams of highly charged positive ions and are used extensively for cyclotron injection, linac injection, and atomic physics research. In this paper, the possible use of ECR heavy-ion sources in the terminals of electrostatic machines is discussed. The basic concepts of ECR sources are reviewed in the next section using the ORNL source as a model. The possible advantages of ECR sources over conventional negative ion injection and foil stripping are discussed in Section III. The last section describes the possible installation of an ECR source in a large machine such as the HHIRF 25-MV Pelletron. 6 refs., 4 figs., 1 tab

  7. Inside launch electron cyclotron heating and current drive on DITE

    International Nuclear Information System (INIS)

    Ashraf, M.; Deliyanakis, N.

    1989-01-01

    Electron cyclotron resonance heating at 60 GHz has been carried out on DITE (R = 1.2 m, a = 0.24 m) to investigate heating and current drive using the extraordinary mode launched with finite k parallel from the high field side. The first clear evidence of Doppler shifted resonance absorption in a near-thermal plasma is obtained. The heating efficiency is observed to fall sharply at densities above cut-off for the wave. At lower densities the increment in power to the limiter is measured during ECRH and is compared with that expected from the global power balance. The degradation in particle confinement often associated with ECRH is observed as an increased particle flux at the boundary driven by local electrostatic fluctuations. Initial experiments on the electron cyclotron wave driven current at the second harmonic show effects that are consistent with the low efficiency expected from theory including trapped particle effects. (author). 9 refs, 4 figs

  8. Magnet field design considerations for a high energy superconducting cyclotron

    International Nuclear Information System (INIS)

    Botman, J.I.M.; Craddock, M.K.; Kost, C.J.; Richardson, J.R.

    1983-08-01

    This paper reports the pole shape designs for a two stage superconducting isochronous cyclotron combination (CANUCK) to accelerate 100 μA proton beams to 15 GeV. The pole shape of the 15 sectors of the first stage 3.5 GeV proton cyclotron provides isochronism over the full energy range and a constant axial tune over all but the lowest energies. Progress on the pole design of the 42 sector 15 GeV second stage is also reported. The magnetic fields are computed from the current distribution of the superconducting coils and the infinitely thin current sheets simulating the fully saturated poles. A least squares method is used to minimize deviations from isochronism by adjusting the size of various elemental shim coils placed around the main coil. The method to obtain the desired axial tune is described

  9. Gas breakdown at cyclotron resonance with a submillimeter laser

    International Nuclear Information System (INIS)

    Hacker, M.P.; Temkin, R.J.; Lax, B.

    1976-01-01

    A pulsed 496-μm CH 3 F laser is used to produce gas breakdown in He at pressures between 1 and 300 Torr in an intense longitudinal magnetic field. Breakdown is detected by the observation of visible light when the electron cyclotron frequency (eB/m) equals the laser frequency, which occurs at B=216 kG for lambda=496 μm. At the lowest helium pressures and near cyclotron resonance, the focused laser intensity of 40 kW/cm 2 gives rise to very large electron heating rates, well beyond the limit of validity of conventional equilibrium breakdown theory. The observed result is an intensity-dependent resonant linewidth, much larger than predicted by equilibrium theories

  10. On the automatic control of the ITER ion cyclotron system

    Energy Technology Data Exchange (ETDEWEB)

    Bosia, G. [Department of General Physics, University of Turin, Via P. Giuria 1, 10 125 Turin (Italy)], E-mail: giuseppe.bosia@to.infn.it

    2007-10-15

    The ITER ion cyclotron heating system requires an efficient control system capable of: (i) providing the desired array radiation spectrum, to optimize plasma coupling and absorption and to minimize parasitic power losses in the plasma edge; (ii) maintaining the RF power flow to the plasma against significant load variations, including fast fluctuations induced by ELMs; (iii) reliably detecting and suppressing RF voltage breakdowns in the array and/or in the transmission system, to avoid local equipment damage and (iv) implementing an accurate real time record of performance. In this paper specific aspects of the tuning control system, related to recent conceptual and engineering effort [K. Vulliez, et al., Design of the ITER ion cyclotron heating launcher based on in-vessel tuning system, Article ID106C, this conference] are addressed.

  11. Ernest Orlando Lawrence (1901-1958), Cyclotron and Medicine

    Energy Technology Data Exchange (ETDEWEB)

    Chu, William T.

    2005-09-01

    On August 8, 2001, Lawrence Berkeley National Laboratory celebrated the centennial of the birth of its founder (and namesake), Ernest Orlando Lawrence. For the occasion, many speeches were given and old speeches were remembered. We recall the words of the late Luis Alvarez, a Nobel Laureate and one of the Lawrence's closest colleagues: ''Lawrence will always be remembered as the inventor of the cyclotron, but more importantly, he should be remembered as the inventor of the modern way of doing science''. J. L. Heilbron and R. W. Seidel, in the introduction of their book, ''Lawrence and His Laboratory'' stated, ''The motives and mechanisms that shaped the growth of the Laboratory helped to force deep changes in the scientific estate and in the wider society. In the entrepreneurship of its founder, Ernest Orlando Lawrence, these motives, mechanisms, and changes came together in a tight focus. He mobilized great and small philanthropists, state and local governments, corporations, and plutocrats, volunteers and virtuosos. The work they supported, from astrophysics and atomic bombs, from radiochemistry to nuclear medicine, shaped the way we observe, control, and manipulate our environment.'' Indeed, all over the civilized world, the ways we do science changed forever after Lawrence built his famed Radiation Laboratory. In this editorial, we epitomize his legacy of changing the way we do medicine, thereby affecting the health and well being of all humanity. This year marks the 75th anniversary of the invention of the cyclotron by Ernest Orlando Lawrence at the University of California at Berkeley. Lawrence conceived the idea of the cyclotron early in 1929 after reading an article by Rolf Wideroe on high-energy accelerators. In the spring of 1930 one of his students, Nels Edlefsen, constructed two crude models of a cyclotron. Later in the fall of the same year, another student, M. Stanley Livingston

  12. Studies of radioisotope production with an AVF cyclotron in TIARA

    Energy Technology Data Exchange (ETDEWEB)

    Sekine, Toshiaki [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    The production of radioisotopes to be used mainly for nuclear medicine and biology is studied with an AVF cyclotron in TIARA. A production method of no-carrier-added {sup 186}Re with the {sup 186}W(p,n){sup 186}Re reaction has been developed; this product may be used as a therapeutic agent in radioimmunotherapy due to the adequate nuclear and chemical properties. For the study of the function of plants using a positron-emitter two-dimensional imaging system, a simple method of producing the positron emitter {sup 18}F in water was developed by taking advantage of a highly-energetic {alpha} beam from the AVF cyclotron. (author)

  13. A pythonic integrated solution for virtual prototyping of cyclotrons

    International Nuclear Information System (INIS)

    Qin Bin; Yang Jun; Xiong Yongqian; Chen Dezhi; Yu Tiaoqin; Dong Tianlin; Zhang Tianjue; Fan Mingwu

    2007-01-01

    Virtual prototyping (VP) is a novel technique in engineering, which is desired to be applied to cyclotron design and development. Some sub-prototyping components, including beam dynamics, magnet, RF system and control system of cyclotrons, have been developed separately, but an integrated platform which encapsulates these different components is required for global system optimization. Considering that the VP integrated platform is a large-scale software and has numerous loose-coupled components, this paper describes the pythonic approach to implement this platform. By mixing the high-level interpreted Python language and the compiled languages like Fortran/C/C++ in an effective method, this approach can achieve a combination of code efficiency, flexibility and compactness

  14. [No role for oral anticoagulants (target INR: 2.0-3.0) after transient ischaemic attack or cerebral infarction of arterial origin; the 'European/Australasian stroke prevention in reversible ischaemia trial' (ESPRIT)].

    Science.gov (United States)

    De Schryver, E L L M; Halkes, P H A

    2008-02-23

    The 'European/Australasian stroke prevention in reversible ischaemia trial' (ESPRIT) aimed to determine whether oral anticoagulation of moderate intensity (target international normalised ratio (INR): 2.0-3.0) is more effective than acetylsalicylic acid in preventing future vascular events in patients with transient ischaemic attack (TIA) or minor stroke of arterial origin. International, multicentre randomised clinical trial. Patients were randomised within 6 months of TIA or minor stroke of arterial origin to oral anticoagulants (target INR: 2.0-3.0; n = 536) or acetylsalicylic acid (30-325 mg daily; n = 532). The primary endpoint was a composite of vascular death, non-fatal stroke, non-fatal myocardial infarction or major bleeding complications. In a post hoc analysis, the efficacy of anticoagulants was compared with that of the combination of acetylsalicylic acid and dipyridamole (200 mg twice daily), a third arm of ESPRIT. Treatment was unblinded, but auditing of endpoints was blinded. Data were analysed on an intent-to-treat basis. The comparison of anticoagulants and acetylsalicylic acid was stopped prematurely because the combination of acetylsalicylic acid and dipyridamole was found to be more effective than acetylsalicylic acid alone. The mean duration of follow-up was 4.6 years (SD: 2.2). The mean INR was 2.57 (SD: 0.86; nearly 70% of the time within target range). The primary endpoint occurred in 99 patients (19%) in the anticoagulation group and 98 patients (18%) in the acetylsalicylic acid group (hazard ratio: 1.02; 95% CI: 0.77-1.35). The hazard ratio was 0.73 (95% CI: 0.52-1.01) for ischaemic events and 2.56 (95% CI: 1.48-4.43) for major bleeding complications. The hazard ratio for the primary outcome event comparing anticoagulants with the combination of acetylsalicylic acid and dipyridamole was 1.31 (95% CI: 0.98-1.75). Oral anticoagulants (target INR: 2.0-3.0) were not more effective than acetylsalicylic acid in the secondary prevention of

  15. Beam dynamics prior to extraction in Kolkata superconducting cyclotron

    International Nuclear Information System (INIS)

    Paul, S.; Debnath, J.; Dey, M.K.; Mallik, C.; Bhandari, R.K.

    2011-01-01

    The Kolkata Superconducting Cyclotron has already accelerated test beams up to its extraction radius. Efforts are underway to extract the internal beam with the aid of the various extraction elements. A detailed study of the accelerated beams dynamics has been carried out to ensure that before extraction, optimum turn separation is achieved and the beam does not cross the harmful third order coupling resonance, while keeping distortions to a manageable levels. This paper discusses those results and the studies conducted. (author)

  16. Alignment of mapping system for magnet cyclotron DECY-13

    International Nuclear Information System (INIS)

    Idrus Abdul Kudus; Taufik; Kurnia Wibowo

    2016-01-01

    A cyclotron is composed of some main and specific components, such as magnet system, ion source, RF system and extractor. A magnet is one of important component in a cyclotron that serves as ion beam bending so the ion beam trajectory is circular. Magnet design should with the requirement of cyclotron that proton energy is 13 MeV. In the construction of the cyclotron magnet, a mapping tool of the magnetic field is required for analysis in shimming process in order to optimize the magnetic field. The magnetic field mapping process is carried out in the median plane of the magnet poles. The magnetic field mapping is carried out repeatedly during the shimming process. During this process, the mapping tool is possible to experience a shift or change in position, for that it is necessary to alignment in order to make sure that the probe is in the median plane of magnet poles and to ensure their positions are always the same on each repetition mapping. During this process, it is possible to experience a shift mapping tool or change the position, for this it is needed to process alignment to ensure the position of the probe is in the median plane magnetic poles and ensure their positions are always the same on each repetition mapping. Alignment on the mapping tool are the height position, zeroing tesla meter and two hall probe mapping. The parameters form the basis for magnetic field measurements based on the three elements: an alignment system on the engine mapping, mapping tool reference point and stage movement of x-y coordinates. Shifts occur due to change in elevation mapping tool table and center coordinates x and y in the mapping process. Changes made to shift mapping coordinates can be shifted as far as 1 to 2 mm for each hall probe in the x and y coordinates with altitude changes 0.05° mapping table and measurement of tesla meter changes in 0.002 T. (author)

  17. Electron Cyclotron Waves Polarization in the TJII Stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Cappa, A.; Martinez-Fernandez, J.; Wagner, D.

    2013-05-01

    This report describes the theoretical calculations related with the electron cyclotron (EC) waves polarization control in the TJII stellarator. Two main aspects will be distinguished: the determination of the vacuum polarization that the wave must exhibit if a given propagation mode in a cold plasma is desired and the calculation of the behavior of the grooved polarizers and other transmission systems used to launch the vacuum wave with the required polarization. (Author) 13 refs.

  18. Cyclotron for medicine and research; Zyklotron fuer Medizin und Forschung

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2012-11-01

    35 tons, weighs the major medical device, which has been delivered in early may at the Julic campus. A heavy-duty crane hoisted the new compact cyclotron to its destination, an underground concrete bunker. There it will from summer 2013 produce radionuclides for the synthesis of radiopharmaca, by which it is possible among others to detect tumors, to pursue metabolic processes, and to investigate the mechanisms of action of drugs.

  19. Occupational radioprotection in the cyclotron laboratory radioisotope production at IEN

    International Nuclear Information System (INIS)

    Fajardo, P.W.; Teixeira, M.V.; Santos, I.H.T.; Pujol Filho, S.V.

    1990-07-01

    The Cyclotron of the Instituto de Engenharia Nuclear is operated mainly for radioisotope production, neutron production studies and irradiation damage analysis. The risks associated to the activities developed in these laboratories are exposition to beta, neutron and gama radiation and contamination. The radioprotection program adapted are presented briefly and the results of the air and surface contamination analysis, liquid efluents and dose equivalent of the workers in 1988 are shown. (author) [pt

  20. First results of correlation electron cyclotron emission on Tore Supra

    OpenAIRE

    Udintsev, V. S.; Goniche, M.; Ségul, J.L.; Giruzzi, G.; Molina, D.; Turco, F.; Huysmans, G. T. A.; Maget, P.; Krämer-Flecken, A.

    2006-01-01

    Measurements of electron temperature fluctuations by means of correlation electron cyclotron emission (ECE) diagnostics aid in understanding the nature of the turbulent transport infusion plasmas. On Tore Supra tokamak, a 32-channel heterodyne ECE radiometer has been upgraded to include two channels for temperature fluctuation measurements. The central frequency of the yttrium iron garnet filter on each channel is remotely monitored by a driver, allowing one to shift the observation volume in...

  1. Stochastic heating in the cyclotron resonance of electrons

    International Nuclear Information System (INIS)

    Gutierrez T, C.; Hernandez A, O.

    1999-01-01

    The study of the different schemes of plasma heating by radiofrequency waves is a very actual problem related with the plasma heating in different machines and the particle acceleration mechanisms. In this work, it is obtained the expression for the temporal evolution of the energy absorbed in the cyclotron resonance of electrons where it is showed the stochastic character of the energy absorption. It is obtained the stochastic criteria in a magnetic configuration of an Ecr type plasma source. (Author)

  2. Project of a test stand for cyclotron ion sources

    International Nuclear Information System (INIS)

    Buettig, H.; Dietrich, J.; Merker, H.; Odrich, H.; Preusche, S.; Weissig, J.

    1978-10-01

    In the work the construction of a test stand for testing and optimization of ion sources of the Rossendorf cyclotron U-120 is represented. The design procedure and the construction of the electromagnet, the vacuum chamber with monant, the vacuum system, the power supply and the detecting system are demonstrated. The results of calculations of the motion of ions in the magnetic field are presented. (author)

  3. Ion cyclotron-resonance heating in a toroidal octupole

    International Nuclear Information System (INIS)

    Barter, J.D.; Sprott, J.C.

    1975-01-01

    rf power near the ion cyclotron-resonance frequency has been used to produce a hundredfold increase (from approximately-less-than1 to approx.100 eV) in the ion temperature in a toroidal octupole device. The heating produces no noticeable instabilities or other deleterious effects except for a high reflux of neutrals from the walls. The heating rate is consistent with theory and the limiting ion temperature is determined by charge-exchange losses

  4. Current drive by electron cyclotron waves in NET

    International Nuclear Information System (INIS)

    Giruzzi, G.; Schep, T.J.; Westerhof, E.

    1989-01-01

    A potentially attractive scenario for steady-state operations in the Next European Torus relies on the use of lower-hybrid (LH) waves for non-inductive current drive in the plasma periphery and of electron cyclotron (EC) waves in the aim of determining the best options for the ECN current drive system and of evaluating the expected current drive efficiency. (author). 7 refs.; 6 figs.; 1 tab

  5. Ion–Cyclotron Resonance Frequency Interval Dependence on the O ...

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... The frequency intervals in which O VI ions get in resonance with ion–cyclotron waves are calculated using the kinetic model, for the latest six values found in literature on O VI ion number densities in the 1.5–3 region of the NPCH. It is found that the common resonance interval is 1.5 kHz to 3 kHz.

  6. Radiation control during the dismantling of a 22 Mev cyclotron

    International Nuclear Information System (INIS)

    Dumas, D.; Killian, C.; Labenski, T.; Brantley, D.

    1976-01-01

    The problem with the cyclotron became apparent when the operators found great difficulty in obtaining an adequate, operational vacuum. After all possible causes were investigated, the replacement of the inner 0-rings was decided to be the only solution. This paper covers the pre-planning and training thought to be necessary to complete the procedure as quickly and safely as possible. The main objective is to show that exposure can be kept to a minimum with proper forethought and supervision

  7. Clinical diagnostic system using a small cyclotron for medical use

    International Nuclear Information System (INIS)

    Yonekura, Y.; Magata, Y.; Konishi, J.

    1990-01-01

    Since a small cyclotron and a positron emission tomography (PET) scanner have been installed at the Kyoto University Hospital in 1983, a great deal of effort has been directed to the clinical application of the PET-cyclotron system. This paper outlines the experience with PET in the clinical setting, including the facility, equipments and staff involved, weekly schedule, typical clinical protocols, and some results from the patients. The system consists of small cyclotron for production of the short-lived positron emitting radionuclides, fully automated synthesis system for labeling various compounds, scanning for measurement of radioactivities, and data analysis system for calculating physiological parameters. A resolving cylinder target system with eight smaller cylinders is equipped for production of C-11, N-13, O-15, and F-18. Labeled compounds are quickly delivered to the PET scanner room by two systems--the continuous delivery system for the labeled gas and the rapid delivery system for the liquid compounds by compressed air. A PET scanner devoted for clinical studies is a multislice whole-body PET scanner. Ten PET studies are performed weekly on the average for measuring blood flow and oxygen and glucose metabolism in the brain, blood flow and glucose and fatty acid metabolism in the heart, blood flow and amino acid uptake in the pancreas, lung ventilation, and tumor glucose metabolism. The availability of PET-cyclotron system is still limited in view of cost. The previous clinical studies suggest the contribution of PET to the the understanding of the mechanism of disease pathophysiology. (N.K.)

  8. Induction linac driven relativistic klystron and cyclotron autoresonance maser experiments

    International Nuclear Information System (INIS)

    Goodman, D.L.; Birx, D.L.; Danly, B.G.

    1991-01-01

    In this paper design and experimental results are presented from two high power microwave generation experiments utilizing a high repetition rate induction linac generated electron beam. A relativistic klystron has generated more than 100 MW microwave pulses in X-band for 50 ns without pulse shortening or breakdown. design studies for the first cyclotron autoresonance maser (CARM) amplifier using an induction linac electron beam are also presented

  9. Radionuclide production and radiopharmaceutical chemistry with BNL cyclotrons

    International Nuclear Information System (INIS)

    Lambrecht, R.M.; Wolf, A.P.

    1985-01-01

    The Brookhaven National Laboratory (BNL) radiopharmaceutical chemistry program focuses on production and utilization of radionuclides having a half-life of > 2 hr. However, a major portion of the BNL program is devoted to short-lived radionuclides, such as 11 C and 18 F. Activities encompassed in the program are classified into seven areas: cyclotron parameters, radiochemistry, design and rapid synthesis of radiopharmaceuticals and labeled compounds, radiotracer evaluation in animals, studies in humans, technology transfer, and several other areas

  10. Design options for an ITER ion cyclotron system

    International Nuclear Information System (INIS)

    Swain, D.W.; Baity, F.W.; Bigelow, T.S.; Ryan, P.M.; Goulding, R.H.; Carter, M.D.; Stallings, D.C.; Batchelor, D.B.; Hoffman, D.J.

    1995-01-01

    Recent changes have occurred in the design requirements for the ITER ion cyclotron system, requiring in-port launchers in four main horizontal ports to deliver 50 MW of power to the plasma. The design is complicated by the comparatively large antenna-separatrix distance of 10--20 cm. Designs of a conventional strap launcher and a folded waveguide launcher than can meet the new requirements are presented

  11. Estimation of magnetic fields in cyclotron AIC-144

    International Nuclear Information System (INIS)

    Daniel, K.; Talach, M.

    2005-11-01

    The method of magnetic fields calculation, what is based on result of incomplete magnetic measurements, in the chamber of cyclotron is described. Special emphasis is given to precision of calculation, in particular concerning an impact of currents flowing in the concentric coils on harmonic components of magnetic induction on particular radiuses in the chamber. In the earlier calculation this impact was ignored or required time-consuming measurements. (author)

  12. Mode converter for electron cyclotron resonance heating of toroidal plasmas

    International Nuclear Information System (INIS)

    Motley, R.W.; Hsuan, H.; Glanz, J.

    1980-09-01

    A method is proposed for improving the efficiency of cyclotron resonance heating of a toroidal plasma by ordinary mode radiation from the outside of the torus. Radiation not absorbed in the first pass is reflected from the inside of the torus by a corrugated surface which rotates the polarization by 90 0 , so that a secondary source of extraordinary waves is created in the high field, accessible region of the plasma

  13. Development of a collision induced dissociation ion cyclotron resonance spectrometer

    International Nuclear Information System (INIS)

    Fan, Y.N.

    1982-01-01

    A transient analysis ion cyclotron resonance spectrometer is developed to investigate the phenomena of collision induced dissociation. The Fourier transform method and the modified maximum entropy spectral analysis or covariance least square method are implemented in measuring the mass spectrum of the ion ensemble. The Fourier transform method can be used in quantitative analysis while the maximum entropy method as developed here is useful for qualitative analysis only. The cyclotron resonance frequency, relaxation time constant, and the relative ion population are observable from the Fourier transform spectrum. These parameters are very important in investigating collision induced dissociation process and other topics in gas phase chemistry. The ion cyclotron resonance spectrometer is not only developed to study fragments and their abundance from a parent ion, but also to determine the threshold energy and reaction cross section in the collision induced dissociation process. When hard sphere model is used in the ion-molecule collision, the radius of acetone ion measured from the reactive cross section is 2.2 angstrom which is very close to the physical dimension of acetone. The threshold energy for acetone ion in collision induced dissociation process is 1.8 eV which is similar to the result obtained by the angle-resolved mass spectrometer

  14. Electrostatic ion-cyclotron waves in a nonuniform magnetic field

    International Nuclear Information System (INIS)

    Cartier, S.L.; D'Angelo, N.; Merlino, R.L.

    1985-01-01

    The properties of electrostatic ion-cyclotron waves excited in a single-ended cesium Q machine with a nonuniform magnetic field are described. The electrostatic ion-cyclotron waves are generated in the usual manner by drawing an electron current to a small exciter disk immersed in the plasma column. The parallel and perpendicular (to B) wavelengths and phase velocities are determined by mapping out two-dimensional wave phase contours. The wave frequency f depends on the location of the exciter disk in the nonuniform magnetic field, and propagating waves are only observed in the region where f> or approx. =f/sub c/i, where f/sub c/i is the local ion-cyclotron frequency. The parallel phase velocity is in the direction of the electron drift. From measurements of the plasma properties along the axis, it is inferred that the electron drift velocity is not uniform along the entire current channel. The evidence suggests that the waves begin being excited at that axial position where the critical drift velocity is first exceeded, consistent with a current-driven excitation mechanism

  15. Foil changer for the Chalk River superconducting cyclotron

    International Nuclear Information System (INIS)

    Hoffmann, C.R.; Kilborn, R.I.; Mouris, J.E.; Proulx, D.R.; Weaver, J.F.

    1985-01-01

    Capture of an injected beam in the Chalk River superconducting cyclotron requires that a carbon stripping foil be accurately placed in a dee to intercept the incoming beam. Foil radial position must be precisely adjustable and foils must be easily replaced. A foil changing apparatus has been designed, built and tested to meet these requirements. The main components are a supply magazine, a transport system, and unloading and loading mechanisms. The magazine is on top of the cyclotron. It holds 300 foils and can be isolated from machine vacuum for refilling. Each foil is mounted on a stainless steel frame. A stainless steel roller chain fitted with 33 copper sleeves (shrouds) carries foils, one per shroud, down a dee stem to the midplane. A 12-bit absolute optical shaft encoder senses foil position. To replace a foil a shroud is positioned at the top of the cyclotron, a foil is removed, and another is transferred from the magazine to the empty shroud. Three stepping motors and associated electronics provide mechanical drive and are interfaced with a CAMAC control system

  16. The cyclotron laboratory and the RFQ accelerator in Bern

    International Nuclear Information System (INIS)

    Braccini, S.; Ereditato, A.; Kreslo, I.; Nirkko, M.; Weber, M.; Scampoli, P.; Bremen, K. von

    2013-01-01

    Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University of Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study

  17. Emittance Measurement for Beamline Extension at the PET Cyclotron

    Directory of Open Access Journals (Sweden)

    Sae-Hoon Park

    2016-01-01

    Full Text Available Particle-induced X-ray emission is used for determining the elemental composition of materials. This method uses low-energy protons (of several MeV, which can be obtained from high-energy (of tens MeV accelerators. Instead of manufacturing an accelerator for generating the MeV protons, the use of a PET cyclotron has been suggested for designing the beamline for multipurpose applications, especially for the PIXE experiment, which has a dedicated high-energy (of tens MeV accelerator. The beam properties of the cyclotron were determined at this experimental facility by using an external beamline before transferring the ion beam to the experimental chamber. We measured the beam profile and calculated the emittance using the pepper-pot method. The beam profile was measured as the beam current using a wire scanner, and the emittance was measured as the beam distribution at the beam dump using a radiochromic film. We analyzed the measurement results and are planning to use the results obtained in the simulations of external beamline and aligned beamline components. We will consider energy degradation after computing the beamline simulation. The experimental study focused on measuring the emittance from the cyclotron, and the results of this study are presented in this paper.

  18. Modelling of non-thermal electron cyclotron emission during ECRH

    International Nuclear Information System (INIS)

    Tribaldos, V.; Krivenski, V.

    1990-01-01

    The existence of suprathermal electrons during Electron Cyclotron Resonance Heating experiments in tokamaks is today a well established fact. At low densities the creation of large non-thermal electron tails affects the temperature profile measurements obtained by 2 nd harmonic, X-mode, low-field side, electron cyclotron emission. At higher densities suprathermal electrons can be detected by high-field side emission. In electron cyclotron current drive experiments a high energy suprathermal tail, asymmetric in v, is observed. Non-Maxwellian electron distribution functions are also typically observed during lower-hybrid current drive experiments. Fast electrons have been observed during ionic heating by neutral beams as well. Two distinct approaches are currently used in the interpretation of the experimental results: simple analytical models which reproduce some of the expected non-Maxwellian characteristics of the electron distribution function are employed to get a qualitative picture of the phenomena; sophisticated numerical Fokker-Planck calculations give the electron distribution function from which the emission spectra are computed. No algorithm is known to solve the inverse problem, i.e. to compute the electron distribution function from the emitted spectra. The proposed methods all relay on the basic assumption that the electron distribution function has a given functional dependence on a limited number of free parameters, which are then 'measured' by best fitting the experimental results. Here we discuss the legitimacy of this procedure. (author) 7 refs., 5 figs

  19. Foil changer for the Chalk River superconducting cyclotron

    International Nuclear Information System (INIS)

    Hoffmann, C.R.; Kilborn, R.I.; Mouris, J.F.; Proulx, D.R.; Weaver, J.F.

    1985-01-01

    Capture of an injected beam in the Chalk River superconducting cyclotron requires that a carbon stripping foil be accurately placed in a dee to intercept the incoming beam. Foil radial position must be precisely adjustable and foils must be easily replaced. A foil changing apparatus has been designed, built and tested to meet these requirements. The main components are a supply magazine, a transport system, and unloading and loading mechanisms. The magazine is on top of the loading mechanisms. The magazine is on top of the cyclotron. It holds 300 foils and can be isolated from machine vacuum for refilling. Each foil is mounted on a stainless steel frame. A stainless steel roller chain fitted with 33 copper sleeves (shrouds) carries foils, one per shroud, down a dee stem to the midplane. A 12-bit absolute optical shaft encoder senses foil position. To replace a foil a shroud is positioned at the top of the cyclotron, a foil is removed, and another is transferred from the magazine to the empty shroud. Three stepping motors and associated electronics provide mechanical drive and are interfaced with a CAMAC control system

  20. Characteristics of possible beam losses in superconducting cyclotron

    International Nuclear Information System (INIS)

    Pradhan, J.; Paul, Santanu; Debnath, Jayanta; Dutta, Atanu; Bhunia, Uttam; Naser, Md. Zamal Abdul; Singh, Vinay; Agrawal, Ankur; Dey, Malay Kanti

    2015-01-01

    In a compact superconducting cyclotron large coherent oscillation and off-centering of the beam may cause large amount of beam loss. The off-centered beam may hit the beam chamber wall prohibiting extraction of the beam. Or it may hit the RF liner surfaces due to vertical blow-up across various resonances during acceleration. The vertical shift of beam caused by the mis-alignment gradually moves the beam out of geometrical median plane eventually leading to internal beam losses. The loss of isochronisms results the reduction of beam intensity depending on the particle phase history. Small field perturbations generated by trim coils have been used to identify the beam loss mechanisms in the superconducting cyclotron at out centre. Besides, the beam loss due to interaction of accelerating ions with residual gases is also discussed. The beam profile obtained from differential and three finger probes gives a clear insight of the loss-mechanism. The paper describes different beam losses observed in the cyclotron with corresponding beam profiles under different field perturbations, Special emphasis is given on characteristics features of beam-current profile to identify the cause of beam loss. (author)