WorldWideScience

Sample records for inmediata con implantes

  1. Carga inmediata con implantes en maxilar superior Immediate loading of implants in the maxilla

    Directory of Open Access Journals (Sweden)

    F. Monje Gil

    2007-08-01

    Full Text Available La carga inmediata en la mandíbula se ha incorporado a la práctica clínica en primer lugar y, por las características del hueso, se realiza de forma protocolizada. Sin embargo, en el maxilar superior no hay evidencia científica para realizarlo de forma cotidiana. Las razones son debidas a que el maxilar superior, en general, alberga una masa ósea de menor densidad. Por otro lado, en el maxilar superior pueden coexistir diferentes densidades óseas (según la clasificación de Misch en el mismo individuo. Además, por las características anatómicas del maxilar superior (reabsorción labiopalatina el alineamiento axial es asumible pero, sin embargo, el paralelismo de los implantes es difícil.16,17 El objetivo del presente trabajo es analizar la información científica de la que disponemos para confirmar si es posible la carga inmediata sobre el maxilar superior. Para ello estudiaremos varios aspectos de la carga inmediata en el maxilar superior: • Sobredentaduras • Prótesis fija completa • Prótesis parcial fija • Prótesis unitaria fija • Requerimientos protésicos • ContraindicacionesImmediate loading in the mandible has been introduced into clinical practice taking first place and, and because of the characteristics of the bone, this is carried out following a protocol. However, in the maxilla there is no scientific evidence for routinely carrying this out. This is because the maxilla, in general, has a lower bone mass density. Moreover, in the maxilla various densities may coexist (according to Misch’s classification in the same individual. In addition, given the anatomic characteristics of the maxilla (lip and palate resorption, axial alignment can be carried out, but implant parallelism is difficult.16,17 The aim of this paper is to analyze the scientific information that we have at our disposal in order to confirm whether immediate loading in the maxilla is possible. For this we will study various aspects of

  2. Comparación de carga inmediata frente a carga convencional de implantes inmediatos con prótesis fijas de arco completo

    OpenAIRE

    Peñarrocha Oltra, David

    2014-01-01

    Comparación de carga inmediata frente a carga convencional de implantes inmediatos con prótesis fijas de arco completo. OBJETIVOS El propósito del estudio fue evaluar las diferencias entre los protocolos de carga inmediata y carga convencional para rehabilitar a pacientes con el maxilar o la mandíbula parcialmente desdentados en los que esté indicada la extracción de todos los dientes remanentes, con prótesis fijas de arco completo sobre implantes dentales inmediatos y no inmediatos, e...

  3. Rehabilitación mediante implantes de carga inmediata con regeneración ósea

    Directory of Open Access Journals (Sweden)

    René Abel Salso Morell

    2015-12-01

    Full Text Available La disponibilidad ósea es uno de los principales elementos a tener en cuenta en la planificación del tratamiento implantológico. La posibilidad de optar por este se encuentra limitada en pacientes con déficit óseo, tanto en cantidad, como en calidad. La regeneración ósea guiada es una técnica quirúrgica, que permite estimular la formación de hueso en zonas específicas, permitiendo una disponibilidad adecuada del mismo, facilitando así esta terapéutica. Pueden realizarse previamente a la colocación de los implantes o durante la colocación de los mismos. Se presenta un caso de rehabilitación protésica por medio de implantes de carga inmediata utilizando una técnica de regeneración ósea, guiada  en el momento de la implantación. Se realizó seguimiento por seis meses, constatándose la integración del implante, así como la adecuada adaptación de la rehabilitación protésica.

  4. Carga inmediata en implantes dentales Immediate loading of dental implants

    Directory of Open Access Journals (Sweden)

    C. Concejo Cútoli

    2005-10-01

    Full Text Available El protocolo de carga convencional en una o dos fases quirúrgicas ha sido evaluado durante los últimos 30 años bajo todas las condiciones clínicas posibles. En comparación, la carga inmediata es un protocolo relativamente nuevo que necesita de una estricta evaluación clínica. Realizamos una búsqueda bibliográfica sobre los ensayos clínicos publicados de carga inmediata en función de las diferentes opciones terapéuticas que se pueden plantear. Se hallaron resultados comparables para las dos estrategias de carga en mandíbulas edéntulas. Para el tratamiento con prótesis inmediata de maxilares totalmente edéntulos, restauraciones parciales e unitarias es todavía necesaria una selección adecuada de pacientes y un diseño conservador de la prótesis provisional. La necesidad de ensayos clínicos sencillos aleatorizados de doble ciego, con suficiente número de pacientes y adecuado seguimiento, que comparen una determinada situación clínica con un patrón oclusal de la prótesis provisional bien definido, son imprescindibles para acabar de confirmar la seguridad de la técnica.The protocol for conventional loading in one or two surgical stages has been evaluated over the last 30 years under all the possible clinical conditions. By comparison, immediate loading is a relatively new protocol that requires strict clinical evaluation. We conducted a search of the literature published concerning clinical trials on immediate loading according to the different therapeutic options that could be considered. Comparable results were found for both loading strategies in edentulous mandibles. For treatment involving an immediate prosthesis for totally edentulous mandibles, partial and single tooth restorations, patients have to be selected adequately and provisional prostheses have to be designed conservatively. In order to completely confirm the safety of the technique, double-blind, simple, randomized clinical trials have to be carried out with

  5. Evolución de 1 año de un paciente rehabilitado con implantes oseointegrados de carga inmediata después de la resección quirúrgica de un cementoblastoma: Reporte clínico Clinical Report: Patient's progress one year after being treated with immediate loading bone integrated implants after removal of cementoblastomas

    Directory of Open Access Journals (Sweden)

    E.J. de Moraes

    2009-12-01

    Full Text Available Se presenta un caso clínico correspondiente a un paciente con diágnostico de dos cementoblastomas, en el cual, posterior a la resección quirúrgica de ambos tumores, se rehabilitó con una prótesis sobre implantes de carga inmediata. Para esto instalaron 4 implantes, utilizando el sistema de Carga Inmediata Speed Máster (Conexão Sistema de Prótesis- São Paulo- Brazil con la instalación de la prótesis 48 horas después de la cirugía. La evolución clínica y radiográfica fue seguida por 14 meses, comprobando que los implantes mantenían una condición adecuadaThe authors present a clinical case of a patient with two cementoblastomas who was treated with four implants installed using Speed Master System. The prosthesis was seated 48 hours after surgery. The clinical and radiographic follow-up was performed 14 months later and it was determined that the implants were in satisfactory conditions.

  6. Carga inmediata de implantes monofásicos postextracción utilizando los expansores roscados atraumáticos: estudio retrospectivo 2001-2011

    Directory of Open Access Journals (Sweden)

    Riham Mostafa Eldibany

    2015-10-01

    Conclusiones: Tras haber analizado toda la secuencia referida a la carga inmediata, podemos concluir que los implantes monofásicos insertados con la aplicación de esta técnica son un procedimiento predecible: su éxito en el maxilar inferior en nuestro estudio de 10 años fue del 98%. Sin embargo, es necesario determinar los casos candidatos para dicho procedimiento, así como las características del implante que favorecen la implantación inmediata.

  7. Superficies de titanio en implantes dentales de carga inmediata

    OpenAIRE

    Aparicio, C.; Padrós, A.; Planell Estany, Josep Anton; Gil, F.J.

    2008-01-01

    Se ha obtenido una capa de fosfato de calcio del mismo contenido mineral que el hueso en la superficie del implante dental de titanio, que tiene como consecuencia una muy rápida y eficaz osteointegración. Esta capa se ha obtenido mediante un método biomimético por vía termoquímica. La capa se une al substrato por enlace químico. Este hecho evita todos los inconvenientes de los métodos de recubrimiento convencionales (plasma spray, ablación láser...) cuya unión es por interacción mecánica, lo ...

  8. Sobredentadura inmediata y con carga tardía: revisión de la literatura Immediate overdenture and overdenture with late loading: literature review

    Directory of Open Access Journals (Sweden)

    Celina Wanderley de Abreu

    2007-03-01

    Full Text Available La rehabilitación oral de los pacientes desdentados totales presenta grandes dificultades, pues diversos factores actúan limitando el tratamiento con prótesis totales convencionales como la severa reabsorción del proceso alveolar, que genera para los pacientes dificultades fonéticas y de masticación, incomodidad, falta de retención y estabilidad de las prótesis. Con el surgimiento de los implantes osteointegrados ideados por el Profesor Branemark, estos aspectos fueron mejorados, por la posibilidad de nuevas opciones de tratamiento como las sobredentaruras muco-implantosoportadas. Sin embargo, el protocolo de Branemark exigía un período de cicatrización de 3 a 6 meses, tiempo que los pacientes deben esperar para la colocación de la prótesis final. De esta forma, la técnica quirúrgica de carga inmediata fue propuesta para abreviar este período, mejorando la fase de transición, al mismo tiempo que reduce los problemas psicológicos asociados. El objetivo del presente estudio es realizar una revisión de literatura acerca de los trabajos que utilizaron sobredentaduras comparando carga inmediata y tardía, discutir la mejor alternativa, así como los factores envueltos en el éxito del procedimiento.The oral rehabilitation of the patients toothless totals presents large difficulties, because diverse factors act limiting the treatment with complete dentures conventional, as severe reabsorption of the alveolar process, generating for the phonetic patient difficulties and of mastication, annoyance, retention lack and stability of the prosthesis. With the emergence of you implant them osseointegratin idealized by Profº Branemark, these aspects were improved by means of the possibility of new treatment options, as the overdentures tissue-implant-supported. However, the protocol of Branemark demanded a period of scaring from three to six months, owing the patients to await this time for the placement of the final prosthesis. This way

  9. Tratamiento con implantes Leader-Nano en paciente con oligodoncia

    Directory of Open Access Journals (Sweden)

    Salvador Javier Santos Medina

    2015-03-01

    Full Text Available Los implantes dentales de titanio han revolucionado el mundo de la rehabilitación desde su surgimiento. De manera particular, el empleo de implantes de carga inmediata acorta el tiempo quirúrgico y protésico, con el consiguiente bienestar estético. Se presenta el caso de una paciente femenina de 32 años de edad, con antecedentes de oligodoncia de ambos incisivos laterales superiores y portadora de prótesis parcial acrílica. Fue atendida por el equipo multidisciplinario de implantes en la Clínica Estomatológica Docente “3 de Octubre” y se le realizó tratamiento de rehabilitación integral con implantes Leader-Nano y prótesis fija con corona acrílica sobre dichos implantes. La implantología fue satisfactoria en la paciente; la mejoría estética y funcional, así como la satisfacción de la paciente, fueron los principales logros obtenidos

  10. Fibroma osificante juvenil trabecular mandibular: presentación de un caso con reconstrucción inmediata mediante un injerto libre de la cresta ilíaca y costocondral

    Directory of Open Access Journals (Sweden)

    Rodrigo Bravo Ahumada

    2015-01-01

    Full Text Available El fibroma osificante juvenil (FOJ es una lesión fibro-ósea benigna pero con potencial biológico agresivo que afecta al esqueleto craneofacial. Su evolución clínica es rápida, manifestándose principalmente por una asimetría facial de poco tiempo de evolución. Radiográficamente es una lesión radiolúcida uni o multilocular bien definida con contenido radiopaco variable. El tratamiento puede variar dependiendo de las características clínicas, imagenológicas e histopatológicas específicas de cada lesión, sin embargo, un tratamiento agresivo con resección es el más indicado. Se presenta un caso de un niño con extenso FOJ trabecular (FOJT mandibular. Se realizó la resección completa de la lesión con un margen de seguridad y reconstrucción inmediata con un injerto de la cresta ilíaca y costocondral. Se realizaron controles postoperatorios durante 7 años en los que no se observaron signos de recidiva asociados a una reconstrucción funcional y estética exitosa.

  11. Implantología post-extracción inmediata: protocolo operativo y evaluaciones oclusales, periodontales y estéticas Inmediately post-extractive implantology: surgical protocol, oclusal, periodontal and aesthetic evaluations

    OpenAIRE

    GL Caccianiga; D Calzavara; A Baldini; RM Baldoni; A Bascones

    2003-01-01

    OBJETIVO DEL TRABAJO: Evaluar la eficacia clínica del protocolo quirúrgico relativo a la colocación inmediata del tornillo en el alveolo post-extrativo. MATERIAL Y MÉTODOS: Han sido evaluados, según los criterios de Albrekston y Buser 45 implantes colocados con la técnica post-extractiva, a los 6 meses y a los 3 años tras la colocación del implante. RESULTADOS: El protocolo aplicado se ha demostrado válido, los porcentajes de éxito han sido parecidos con aquellos de la técnica tradicional, co...

  12. Galactorrea grave tras aumento mamario con implantes Severe galactorrhea after mammary augmentation with implants

    Directory of Open Access Journals (Sweden)

    F.T. Fidalgo Rodríguez

    2012-06-01

    Full Text Available La galactorrea es una complicación poco frecuente después de la cirugía plástica mamaria. Su causa aun es desconocida, aunque lo más probable es que su aparición tenga un origen multifactorial. En el caso que presentamos la paciente desarrolló incremento simétrico del volumen de ambas mamas después de un cirugía de aumento mamario. No se detectaron cambios en los valores de prolactina. El proceso no respondió al tratamiento con bromocriptina. La galactorrea postquirúrgica con frecuencia sigue un curso benigno y autolimitado, culminando con resolución espontánea. Dependiendo de la severidad de los síntomas, su tratamiento puede ser médico y/o quirúrgico, con drenaje o incluso retirada de los implantes mamarios.Galactorrhea is a complication rarely observed after mammary plastic surgery. The cause remains unknown although it's likely to be multifactorial. In the reported case, the patient described symmetric massive engorgement of both breasts after augmentation mammoplasty. No significant change was detected in the postoperative prolactin values. The condition was unresponsive to treatment with bromocriptine. Postsurgical galactorrhea often follows a benign course culminating in spontaneous resolution Depending on symptom severity, treatment may be medical with the prescription of dopaminergic agonists, and/or surgical with drainage or even removal of the mammary implants.

  13. Pros and cons of transcatheter aortic valve implantation (TAVI).

    Science.gov (United States)

    Terré, Juan A; George, Isaac; Smith, Craig R

    2017-09-01

    Transcatheter aortic valve implantation (TAVI) or replacement (TAVR) was recently approved by the FDA for intermediate risk patients with severe aortic stenosis (AS). This technique was already worldwide adopted for inoperable and high-risk patients. Improved device technology, imaging analysis and operator expertise has reduced the initial worrisome higher complications rate associated with TAVR, making it comparable to surgical aortic valve replacement (SAVR). However, many answers need to be addressed before adoption in lower risk patients. This paper highlights the pros and cons of TAVI based mostly on randomized clinical trials involving the two device platforms approved in the United States. We focused our analysis on metrics that will play a key role in expanding TAVR indication in healthier individuals. We review the significance and gave a perspective on paravalvular leak (PVL), valve performance, valve durability, leaflet thrombosis, stroke and pacemaker requirement.

  14. Resultados del tratamiento con implantes dentales osteointegrados en la fase quirúrgica

    Directory of Open Access Journals (Sweden)

    Oviedo Pérez Pérez

    Full Text Available Objetivo: evaluar los resultados del tratamiento con implantes dentales osteointegrados en la fase quirúrgica. Métodos: se realizó un estudio longitudinal y prospectivo en 802 pacientes en quienes se colocaron 2 165 implantes, en la Clínica Estomatológica Provincial Docente de Santiago de Cuba y la Facultad de Estomatología de La Habana en el decenio 20002009. Se evaluaron las variables: técnica quirúrgica, longitud y diámetro de los implantes, complicaciones intraoperatorias y complicaciones postoperatorias, los resultados del tratamiento se evaluaron en supervivencia y fracaso. Resultados: se logró la supervivencia de los implantes en 705 pacientes para el 87,9 % y se produjo el fracaso en 97 pacientes para el 12,1 %. Se colocaron 2 165 implantes, se logró efectividad de 2 055 para el 94,9 % y fracasaron 110 que representan el 5,08 %. No existen diferencias significativas de los resultados de acuerdo a la técnica quirúrgica empleada. Los implantes que más fracasaron fueron los de 10 mm, para el 34,9 % y 8 mm con el 13,1 %. La efectividad se incrementa a medida que aumenta el diámetro. En las complicaciones intraoperatorias el fracaso fue mayor en relación con la perforación de la tabla ósea con el 92,9 %, inestabilidad con el 86 % y la dehiscencia ósea con el 57,4 %. En el postoperatorio fue notable que en el 100 % de los casos con dolor existió fracaso de los implantes. Conclusiones: en la etapa quirúrgica existe una fuerte asociación de los resultados con la longitud, diámetro de los implantes y la presencia de complicaciones intraoperatorias y postoperatorias.

  15. Estudio multicéntrico prospectivo con implantes MG-OSSEOUS a los 2 años de seguimiento Multicentric prospective study of MG-OSSEOUS implants at 2 year follow-up

    Directory of Open Access Journals (Sweden)

    E. Serrano

    2009-10-01

    Full Text Available Introducción. La implantología es uno de los procedimientos terapéuticos más realizados en nuestros días. El objetivo del presente estudio es presentar los resultados de los los implantes MG-OSSEOUS (Mozo-Grau, S.L., Valladolid, España a los 2 años de seguimiento. Material y método. La empresa Scientific Management in O&SS (Barcelona, España, diseñó unos cuestionarios exhaustivos que rellenaron, por cada caso, cada uno de los profesionales del estudio. La compilación y el tratamiento estadístico de los datos obtenidos fue extremadamente pormenorizada. Se aplicaron estudios de subpoblaciones desde la población N de implantes totales colocados y, mediante la aplicación de ANOVA, se valoraron parámetros concretos en dichas subpoblaciones para determinar y concluir la influencia de los mismos sobre el fracaso de los implantes. Resultados. Se colocaron 1475 implantes en 480 pacientes entre Junio de 2005 y Mayo de 2006, con una supervivencia del 98,2% con un seguimiento de 2 años de promedio con las prótesis cargadas. Se detallan los implantes por posiciones, diámetros y longitudes y se analizan los resultados en las subpoblaciones de implantes postexodoncia, implantes de carga inmediata e implantes asociados a injertos. Discusión. Se focaliza, realizando un amplio repaso de la bibliografía actual, en el alto fracaso obtenido en nuestro estudio de los implantes de diámetro ancho (4,25 mm postexodoncia y en la versatilidad del empleo de los implantes de diámetro estrecho (3,4 mm en cualquier posición oral para cualquier tipo de carga. Conclusiones. Este estudio es la completa antítesis de la filosofía, en el que se interpreta de una sola manera, científica y reproducible, una serie de resultados en el campo de la implantología oral, nuestra realidad. Seguiremos este estudio para alargar el tiempo observacional, como mínimo, a 5 años.Introduction. Implantology is the most common therapeutic procedure nowadays. Professor P

  16. Reconstrucción mamaria con expansor tisular e implante: Indicaciones y experiencia en 24 casos Breast reconstruction with tissue expander: Indications and experience in 24 cases

    Directory of Open Access Journals (Sweden)

    C. Gutiérrez Gómez

    2012-12-01

    Full Text Available En la actualidad, la reconstrucción mamaria forma parte integral del tratamiento del cáncer de mama; la selección de la paciente es crítica para obtener resultados satisfactorios. El presente trabajo recoge nuestra experiencia en reconstrucción mamaria con expansión tisular e implantes, haciendo hincapié en la selección de las pacientes candidatas a este método reconstructivo. Revisamos las reconstrucciones mamarias realizadas en un período comprendido entre los años 1998 y 2008 por la misma cirujana, analizando factores como tipo de mastectomía, edad, tiempo de la reconstrucción (inmediata o diferida, causa de la mastectomía, tipo de expansor y prótesis utilizados, complicaciones y satisfacción de las pacientes. En todas excepto en una, la reconstrucción se realizó en dos tiempos operatorios; durante el primero se hizo la colocación del expansor tisular y en el segundo, el cambio por la prótesis mamaria definitiva. Se realizaron un total de 24 reconstrucciones mamarias en 19 pacientes en el período de 10 años revisado, 14 unilaterales y 5 bilaterales. Las complicaciones presentadas en este grupo de pacientes fueron del 16,6 %. El seguimiento de las pacientes fue de 2 a 10 años. Solamente en 1 caso de cuadrantectomía, se realizó la reconstrucción de forma diferida por antecedente de radioterapia (4,1 %. En nuestra opinión, la reconstrucción mamaria con expansor tisular e implante es un procedimiento seguro, reproducible y con bajo índice de complicaciones, sin el inconveniente añadido de ocasionar morbilidad en el a área donante.Nowadays, breast reconstruction is part of breast carcinoma treatment; patient's selection plays an important role in satisfactory results. The present paper reports our experience in breast reconstruction with tissue expander/implant and emphasizes the importance of choosing the candidates for this method of reconstruction. We review the breast reconstructions realized in a 10 year period

  17. Sobredentadura sobre implantes en paciente con múltiples caries. Reporte de caso.

    OpenAIRE

    Rengifo Alarcón, Carlos Alberto; Vicente Zamudio, Eduardo Gregorio; Balarezo Razzeto, José Antonio; Matta Morales, Carlos

    2014-01-01

    Hasta hace poco tiempo el tratamiento de pacientes desdentados totales era mediante la instalación de prótesis que iban a ser soportadas por las estructuras remanentes de los maxilares sobrela mucosa y la retención, estabilidad y soporte dependían de la cantidad de hueso remanente, forma de los maxilares, calidad de saliva presente, todos éstos influenciados por la capacidadpsicomotriz del paciente. Con la introducción de los implantes dentales y más aun los implantes endo-óseos se ha revoluc...

  18. La historiografía y la Historia Inmediata: La experiencia latina de historia a debate (1993-2006

    Directory of Open Access Journals (Sweden)

    Carlos Barros Guimeráns

    2009-12-01

    Full Text Available A partir de la experiencia de Historia a Debate en el ámbito latinoamericano, se da pie a la reflexión sobre las oportunidades que ofrece una Historia Inmediata, verdadera y literalmente actual. Exponiendo el desarrollo de la iniciativa “Historia a Debate”, y especialmente de sus congresos (así como de su web, su lista de distribución y la serie de encuentros y encuestas que se han llevado a cabo, se llega a la conclusión que para hacer efectiva una auténtica Historia Inmediata, han de cumplirse con los siguientes requisitos: dejar atrás el eurocentrismo y el etnocentrismo; imponer el multilingüismo historiográfico; trabajo en red; diferenciación con la historia contemporánea; cambiar los paradigmas historiográficos generales; escribir una historia comprometida, plural y profesional; dar mayor espacio a la historia social y multicultural.__________________ABSTRACT:From the experience of "Historia a Debate" in the Latin American area, it begin a reflection about opportunities that a true and currently Immediate History could offer. The paper shows the development of this initiative called "Historia a Debate" and specially its congresses (as well as its Website, its list of distribution and the series of encounter and surveys that has been carried out, it reaches the conclusion that to have a true Immediate History, it needs the following requirements: to give up with Euro-centrism and ethnocentrism; geo-historical multilinguism; to work in network; differentiation with Contemporary History; to change general geo-historical paradigms; to write a more plural, professional and jeopardized history; to give more importance to a social and multicultural history.

  19. Colgajo dermoglandular de apoyo en mastopexia con implantes: técnica de la hamaca

    Directory of Open Access Journals (Sweden)

    A. Alí

    2013-12-01

    Full Text Available La ptosis mamaria es consulta frecuente en la práctica del cirujano plástico, y las opciones quirúrgicas para su corrección son múltiples. A pesar de los avances en el tratamiento de esta alteración, los resultados impredecibles y las posibles complicaciones siguen siendo frecuentes, sobre todo cuando se asocia la colocación de implantes mamarios. La dehiscencia de la herida, la exposición del implante y la modificación de la forma de la mama, en especial del polo inferior, pueden estar presentes a corto o largo plazo en las pacientes sometidas a cirugía de pexia mamaria con implantes. Presentamos una nueva técnica quirúrgica para suspensión y protección del polo inferior de la mama a partir de un colgajo dermoglandular de pedículo interno inferior que llamaremos "hamaca". Este colgajo, nos permite mantener más estable la forma de la mama a lo largo del tiempo y brindar así una mayor protección al implante en caso de dehiscencia de la herida.

  20. Rehabilitación de paciente fumador con prótesis hibrida sobre seis implantes: Reporte de caso

    OpenAIRE

    López López, Carmen Eliana; Quintana del Solar, Martin

    2016-01-01

    La prótesis sobre implantes es una buena alternativa de tratamiento frente a los tratamientos convencionales de prótesis total en pacientes con edentulismo total. Este tratamiento se ha venido realizando con éxito en losúltimos años y constituye una realidad clínica de alto valor. El presente artículo reporta el caso clínico de un paciente de sexo masculino fumador donde se realizó la rehabilitación del maxilar superior con una prótesis tipohibrida sobre 6 implantes. A continuación se describ...

  1. Rescate de colgajo muscular de trapecio con isla cutánea en paciente lesionado medular que precisa rehabilitación inmediata Rescue of a pedicled trapezious muscle flap with skin paddle in a patient with spinal cord injury who needded inmediate rehabilitation

    Directory of Open Access Journals (Sweden)

    J.M. Arévalo Velasco

    2011-12-01

    Full Text Available La terapia por presión negativa (subatmosférica es una modalidad no invasiva de tratamiento que hoy en día está incluida en el arsenal terapéutico de cualquier Servicio no sólo de Cirugía Plástica, sino también de Cirugía General, Cirugía Vascular y Traumatología. Se puede aplicar en el tratamiento de heridas tanto crónicas como agudas más o menos complejas, con el fin de evitar aumentar el tiempo y el número de curas necesarias y además el realizar cirugías que conlleven una elevada morbilidad para el paciente. Presentamos el caso de un paciente con cuadro depresivo secundario a la mala evolución clínica sufrida tras el desarrollo de una lesión medular transversa D4 ASIA C (incompleta de causa iatrogénica postquirúrgica (vertebroplastia-fusión vertebral por aplastamiento vertebral D3-D4, en el que tras más de 6 meses de evolución tórpida de una úlcera dorsal alta, se realizó un colgajo de músculo trapecio pediculado con paleta cutánea para cobertura del defecto, en cuyo postoperatorio inmediato sufrió, de nuevo iatrogénicamente, una pérdida parcial de dicha paleta y un seroma importante en la zona dadora. Consideramos de interés este caso porque la aplicación de terapia de presión negativa empleando el sistema VAC® nos permitió: 1 Minimizar la pérdida de tejido del colgajo. 2 Disminuir el número de curas semanales hasta 1 ó 2. 3 Disminuir también el tiempo empleado en cada cura. 4 Que el paciente pudiera desplazarse en su silla de ruedas con dos sistemas VAC® portátiles hasta el gimnasio para no abandonar su programa de rehabilitación. 5 Que ante una evolución rápida e inesperada, el paciente experimentara una notable mejoría clínica de su estado depresivo-ansioso y 6 La colocación final de un sistema VAC-VIA® de última generación sobre los autoinjertos, para que el paciente pudiera continuar su tratamiento de terapia ocupacional y fisioterápico de extremidades superiores. Consideramos las

  2. Retirada de implantes mamarios y corrección simultánea con colgajo dermoglandular inferior: técnica de mastopexia con autoprótesis

    Directory of Open Access Journals (Sweden)

    A. Rancati

    2014-09-01

    Full Text Available Los cirujanos plásticos nos enfrentamos cada vez con más frecuencia en nuestra consulta a pacientes que desean o necesitan retirar sus implantes mamarios. Algunas de estas pacientes rechazan la idea de un reemplazo protésico, pero son exigentes con el resultado cosmético postoperatorio. Describimos la técnica empleada en 68 casos consecutivos y los resultados que hemos obtenido al tratar las secuelas en la mama tras la retirada de los implantes, fundamentalmente una disminución de volumen asociada a ptosis y excedente cutáneo. Esta técnica se basa en la extracción de los implantes y correccion mamaria simultanea con colgajo dermoglandular inferior que denominamos "autoprotesis" asociado a injerto graso simultáneo. Los resultados logran mejorar la forma, proyección y conificacion de la mama tras la retirada de los implantes, con un alto grado de satisfacción por parte de las pacientes.

  3. Reconstrucción inmediata de cuero cabelludo

    Directory of Open Access Journals (Sweden)

    O. Iribarren Brown

    Full Text Available Presentamos una serie de casos realizados en el Servicio de Cirugía del Hospital Clínico San Pablo en Coquimbo, Chile, entre Abril de 1998 y Abril de 2005. Se trata de un grupo de estudio de 22 pacientes consecutivos con pérdida traumática o quirúrgica del cuero cabelludo, mayor de 3cm de diámetro. Se empleó para la reconstrucción colgajo semilunar, en espejo o en remolino vascularizados a partir de las ramas principales del cuero cabelludo. Analizamos en cada caso el tamaño del defecto, pérdida de hueso asociada, tipo de cirugía, resultados de la cobertura y complicaciones. La edad media de los pacientes fue de 40.6 años con un rango entre 3 y 71 años. El área anatómica comprometida fue parietal en 11 pacientes (50%, temporal en 7 (31,8%, occipital en 3 (13,6% y frontal en 1 caso (4,5%. La causa de la pérdida de sustancia fue resección de tumores malignos o benignos en 10 casos, postraumática en 5, postquirúrgica en 4, y por alopecia en 3. El tamaño medio del defecto fue de 147 cm² con un rango entre 28 y 615 cm² . El colgajo empleado fue doble en espejo en 10 casos (50%, semilunar de deslizamiento en 9 (36,4% y en remolino en 3 (13,6%. En 6 pacientes se utilizó un injerto dermo-epidérmico para cerrar un defecto residual del área dadora del colgajo (dos semilunares y dos en espejo. Veintiun pacientes (45% evolucionaron sin incidencias, con cicatrización del colgajo en un plazo máximo de 21 días. Un paciente con pérdida ósea tras dos craneotomías, presentó necrosis parcial distal del colgajo y falleció por neumonía aspirativa. Comparamos los tres tipos de reparación de acuerdo al tamaño del defecto y a la superficie del mismo. La elección de colgajo doble en espejo, remolino o semilunar, al aplicar la prueba de Kruskal Wallis, no se relacionó con la superficie del defecto, y la elección del colgajo fue atribuible al azar, p > 0.05. La principal razón para escoger uno u otro fue la ubicación del defecto

  4. Implante con el sistema de reparación herniaria inguinal de prolene (Prolene hernia system

    Directory of Open Access Journals (Sweden)

    José Goderich Lalán

    2002-04-01

    Full Text Available Se realizó un estudio clinicodescriptivo y prospectivo del seguimiento de 21 pacientes a los que se les realizó implante sistema de reparación herniaria inguinal de prolene en hernias inguinales, reproducidas entre el 15 de octubre de 1998 y el 31 de marzo de 1999, con el objetivo de evaluar sus resultados. En todos los casos se utilizó el método de cirugía de corta estadía, anestesia local y sedación o espinal y antibioticoterapia profiláctica. En el seguimiento a muy corto plazo no se reportan recidivas y ninguna complicación posoperatoria. Más de la mitad de los pacientes había recibido más de 2 operaciones. La media de edad fue 49 años y el sexo predominante el masculino. La técnica que se utilizó para implante fue la recomendada por los fabricantesA clinical descriptive and prospective study of the follow-up of 21 patients who received implant of the Prolene inguinal hernia repair system in inguinal hernias reproduced between October l5th, 1998, and March 31st, 1999, was conducted aimed at evaluating the results. The short-stay surgery method, local anesthesia and sedation, or spinal anesthesia and prophylactic antibiotic therapy were used in all cases. No relapses or postoperative complications were reported in a very short-term follow-up. More than half of the patients had undergone more than 2 operations. Average age was 49 and there was a predominance of males. The technique used for the implant was the one recommended by the manufacturers

  5. Estudio de los factores relacionados con el grado de satisfacción post-reconstrucción mamaria con implantes

    OpenAIRE

    Brea García, Beatriz

    2016-01-01

    Material y métodos Se diseño un estudio retrospectivo de las reconstrucciones mamarias realizadas con implantes a 111 mujeres entre los años 1999 y 2011 en el Servicio de Cirugía Plástica, Estética y Reparadora del Complexo Hospitalario Universitario de Santiago de Compostela. Se estudiaron las posibles variables que podrían estar relacionadas con el grado de satisfacción post-reconstrucción expresado por las pacientes. Al mismo tiempo, se realizó una valoración del resultad...

  6. Potencial evocados corticales y evaluación lingüística de pacientes con implante coclear

    Directory of Open Access Journals (Sweden)

    Liudis Reina

    2011-12-01

    Full Text Available El objetivo de este trabajo fue examinar la utilidad del Potencial Evocado Auditivo Cortical (PEAC como herramienta objetiva que nos permita cuantificar el proceso de rehabilitación en pacientes con implante coclear. Se conformó una muestra de 20 pacientes, 12 del sexo masculino y con edades entre 7 y 16 años. Todos portadores de un Implante Coclear (IC modelo Clarion HiRes 90K. Todas las variables mostraron una correlación estadísticamente significativa con la etapa del proceso de rehabilitación en que se encontraba cada paciente. Los PEAC registrados en pacientes con IC muestran una morfología muy similar a la que se obtiene en sujetos normoyentes, registrándose los componentes que caracterizan esta respuesta (P1, N1, P2 y N2. Se evidenció una correlación estadísticamente significativa entre las etapas de rehabilitación y la latencia de los componentes P1 y N1. También hubo correlación estadísticamente significativa entre el por ciento de fonemas erróneos calculados tras la aplicación de la prueba del Registro Fonológico Inducido y la latencia del componente P1. Contar con herramientas objetivas como el PEAC nos garantizaría un mayor y mejor aprovechamiento de la rehabilitación lingüística, así como podría ayudar a perfeccionar las técnicas de rehabilitación de los pacientes con implante coclear.

  7. Dientes estabilizados con implantes endodónticos intraóseos como pilares de prótesis

    Directory of Open Access Journals (Sweden)

    Soraya Emilia Almagro Urrutia

    2003-08-01

    Full Text Available Se muestran 2 casos clínicos de pacientes que presentaban dientes con movilidad grado III, a los cuales se les realizó la técnica del implante endodóntico intraóseo, que consiste en la colocación de un perno o implante de cromo cobalto molibdeno a través del conducto radicular hasta pleno tejido óseo, con el objetivo de prolongar su longitud radicular. Los casos se evaluaron a los 15 y 45 días posimplantación y evolucionaron satisfactoriamente, por lo que se decidió comenzar el tratamiento protésico utilizando precisamente como pilares los dientes implantados. Ambos casos fueron evaluados a los 45 días después de la rehabilitación y cada 90 días hasta la fecha. Su evolución fue satisfactoria y no presentaron ninguna patología clínica y radiográfica.2 clinical cases of patients that presented tooth with degree III mobility, in which the technique of intraosteal endodontic implant, consisting in the placement of a dowel or implant of chrome-cobalt molybdenum through the radicular duct to full bone tissue, was applied aimed at prolonging their radicular length. The cases were evaluated 15 and 45 days after the implantation. As their evolution was satisfactory it was decided to begin the prosthetic treatment by using precisely the implanted tooth as abutements. Both cases were evaluated 45 days after the rehabilitation and every 90 days up to date. Their evolution was good and there were no clinical or radiographic pathologies.

  8. ‘As found’ y la experiencia del fragmento. Debate entre imagen y preexistencia en la producción artística británica de la inmediata posguerra

    Directory of Open Access Journals (Sweden)

    Ramón Serrano Avilés

    2009-07-01

    Full Text Available Por diferentes circunstancias históricas, la interpretación canónica de la producción artística durante los años de la inmediata posguerra, ha pasado al margen de determinados aspectos de la modernidad. Especialmente significativas de esta circunstancia fueron las propuestas por el Dadaísmo, sus reflexiones en relación con la ciudad moderna y el papel asignado a la imagen y los objetos en una emergente sociedad de consumo, que este ensayo trata de esclarecer de acuerdo a su legado en el caso particular del Reino Unido.

  9. Management of radiation oncology patients with implanted cardiac pacemakers or implant able cardioverter defibrilators; Tratamiento de pacientes en radioterapia con marcapasos o desfibriladores automaticos implantables

    Energy Technology Data Exchange (ETDEWEB)

    Martin Martin, G.

    2012-07-01

    The increase in life expectancy along with the technological development in the last decades has resulted in an increase in the number of patients requiring pacemaker implants or implantable cardioverter defibrillators worldwide. An increase in the number of patients with implanted cardiac devices in radiotherapy is also expected due to the risk factors in common between heart disease and cancer. In 1994 the American Association of Physicists in Medicine (AAPM) released a report about the management of radiation oncology patients with implanted cardiac pacemakers. The addition of new technologies, both in radiotherapy units and in the manufacturing process of heart devices, has shown the need for an updated protocol for the management of these patients. In this work, the most important articles published after the report of the AAPM have been compiled, in order to analyze the effects not previously studied such as dose rate, scattered radiation, electromagnetic interference or random failures produced by neutrons and protons. Additionally, the latest recommendations given by the manufacturers have been analyzed and, finally, some indications are given as an updated guide for the management of radiation oncology patients with pacemakers or cardioverter defibrillators implanted. (Author)

  10. Exodoncia atraumática e implante post exodoncia sin colgajo combinado con injerto gingival libre

    OpenAIRE

    García Linares, Sixto; Yon Guerrero, Helen

    2010-01-01

    Presentamos un caso donde se describe la técnica de exodoncia atraumática, colocación de un implante post exodoncia y cierre por primera intención mediante un injerto gingival libre. El uso de implantes post exodoncia necesita varias condiciones para poder realizarse, entre ellas: paredes óseas conservadas, hueso alveolar más allá del ápice mayor a 4 mm. , margen gingival conservado, ausencia de fístula, etc. El injerto gingival libre permite una cicatrización por primera intención n...

  11. Colgajo dermoglandular de apoyo en mastopexia con implantes: técnica de la hamaca

    OpenAIRE

    A. Alí; C. Zuleta-Bechara; V. Vassaro

    2013-01-01

    La ptosis mamaria es consulta frecuente en la práctica del cirujano plástico, y las opciones quirúrgicas para su corrección son múltiples. A pesar de los avances en el tratamiento de esta alteración, los resultados impredecibles y las posibles complicaciones siguen siendo frecuentes, sobre todo cuando se asocia la colocación de implantes mamarios. La dehiscencia de la herida, la exposición del implante y la modificación de la forma de la mama, en especial del polo inferior, pueden estar prese...

  12. Vivir con un desfibrilador automático implantable: un estudio cualitativo de las experiencias de los pacientes

    Directory of Open Access Journals (Sweden)

    Inmaculada Paneque Sánchez-Toscano

    2014-06-01

    Full Text Available Objetivo principal: Conocer la experiencia de los pacientes portadores de Desfibrilador Automático Implantable (DAI de la Unidad de Electrofisiología y Arritmias del Hospital Universitario Virgen del Rocío de Sevilla. Metodología: Estudio cualitativo mediante entrevistas semiestructuradas a 11 personas con DAI implantado. Se realizó un análisis de contenido teniendo en cuenta el objetivo de la investigación, las categorías de análisis creadas y las emergentes. Resultados principales: Los temas identificados fueron: la experiencia de vivir con un DAI, las descargas, las estrategias de adaptación, los cambios físicos, emocionales y en el estilo de vida, la vida sexual y la prohibición de conducir. Conclusión principal: Aunque la mayoría de los pacientes aceptan el dispositivo identificando las variables que influyen en la adaptación, existen limitaciones derivadas de cambios físicos, emocionales y en el estilo de vida. Los profesionales sanitarios han de valorar potenciales dificultades de adaptación o alteraciones psicológicas con el fin de facilitar las intervenciones necesarias.

  13. Aumento de dorso nasal con implante blando de tejido conectivo laxo y cartílago troce

    Directory of Open Access Journals (Sweden)

    Mariana Vásquez-García

    Full Text Available Introducción y Objetivo: Están descritas innumerables técnicas para el aumento del dorso nasal. Los injertos autólogos son el material preferido en la reconstrucción nasal debido a su biocompatibilidad y a su menor riesgo de infección y exposición. La técnica de cartílago troceado envuelto en fascia temporal se ha popularizado porque evita la visualización de los injertos a través de la piel del dorso nasal. Nuestro estudio tiene como objetivo demostrar que también el tejido conectivo laxo retroauricular es una envoltura útil para conformar con el cartílago troceado un implante blando que aumente el dorso nasal, proporcionando un resultado estético natural. Material y Método: Realizamos un estudio retrospectivo, entre diciembre de 2012 a diciembre de 2015 con 15 pacientes sometidos a aumento de dorso nasal con cartílago troceado de septum y concha auricular envuelto en tejido conectivo laxo retroauricular, utilizando la vía de rinoplastia externa. Evaluamos los resultados de forma subjetiva con un cuestionario entregado a los pacientes y observando las fotos pre y postoperatorias a corto, medio y largo plazo. Objetivamente medimos las alturas del dorso nasal pre y postoperatoriamente. Resultados: Todos los pacientes presentaron resultados muy satisfactorios. El valor promedio de aumento del dorso nasal a los 3 meses de postoperatorio en nasion fue de 0.38 cm, en rinion de 0.39 cm y en suprapunta de 0.41 cm, manteniéndose iguales valores a los 6, 12 y 18 meses. Conclusiones: Destacamos los beneficios de la envoltura con tejido conectivo laxo retroauricular para cubrir de forma natural las irregularidades del dorso nasal, eliminando el estigma de nariz operada (fibrosis y cicatrización anómala. Su viabilidad en la zona receptora (dorso nasal lo hace muy recomendable para la corrección de deformidades de esta zona. Es por ello que recomendamos su uso como alternativa para corregir hundimientos de dorso nasal de origen

  14. Efecto de un tratamiento agudo con norgestomet en la dinámica folicular de vacas Cebú x Holstein sincronizadas con implantes de norgestomet y eCG

    Directory of Open Access Journals (Sweden)

    R. Páez

    2005-01-01

    Full Text Available El objetivo del presente estudio fue evaluar el efecto de una inyección de norgestomet en la dinámica folicular de vacas Cebú x Holstein sincronizadas con implantes de norgestomet. Se utilizaron 50 vacas en lactación con más de 60 días posparto, las cuales recibieron un implante de 3 mg de norgestomet y una dosis luteolítica de PGF2a (día cero. El día cinco, a 25 vacas (grupo Norg, se les administraron 1.8 mg de norgestomet intramuscular (IM y 25 vacas (grupo testigo, recibieron 3 ml de solución salina. El noveno día se retiró el implante, se realizó un destete temporal por 72 h y los animales fueron divididos al azar dentro de sus tratamientos para recibir (n = 23 o no (n = 27 500 UI de eCG. Posteriormente, las vacas fueron observadas durante cinco días en forma continua para la detección de signos de estro. Se realizaron diariamente ecografías de los ovarios desde el día de la inserción del implante hasta la presentación de estro. El tratamiento agudo con norgestomet provocó recambio del folículo dominante (FD en 40% (10/25 de las vacas, contra 16% (4/25 del grupo testigo (P 0.05 el porcentaje de vacas que presentaron estro ni el tiempo de presentación del mismo. Se concluye que el tratamiento agudo con norgestomet, durante la sincronización del estro con progestágenos, provoca atresia y recambio folicular. Sin embargo, este efecto depende de la etapa de desarrollo del folículo dominante al momento del tratamiento.

  15. Photo and cathode luminescence emission in oxide silicium films implanted with silicium; Emision de foto y catodoluminiscencia en peliculas de oxido de silicio termico implantadas con silicio

    Energy Technology Data Exchange (ETDEWEB)

    Flores, F; Aceves, M. [Instituto Nacional de Astrofisica Optica y Electronica, Mexico, D.F. (Mexico); Carrillo, J. [Benemrita Universidad Autonoma de Puebla, Puebla (Mexico); Dominguez, C. [Universida Autonoma de Barcelona, Barcelona (Spain); Falcony, C. [Instituto Politecnico Nacional, Mexico, D.F. (Mexico)

    2001-10-01

    We studied the photo and cathodoluminescence of Silicon Rich Oxides (SRO) obtained by ion implant of Si in thermal oxides. Doses of 10{sup 1}6 cm{sup -}2 (low dose) and 10{sup 1}7 cm{sup -}2 (high dose) and implant energy of 150 keV were used. The films were annealed for 30, 60 and 180 minutes in nitrogen at 1100 Celsius degrees. The spectra show photo and cathodoluminescence emission in the visible range, the bands in the spectra change with the conditions of ion implant and annealing. The films without thermal treatment in both dose present photoluminescence bands around 1.9 eV (band B) and 2.4 eV (band C). With the thermal treatments, the band B disappears. In the case of the films with low dose, the band C shows a blue shift and a decrease in intensity. The high dose films have a band centered in 1.7 eV (band A) that increases its intensity with annealings. The cathodoluminescence bands in all the cases are in 2.7 eV (band D) and they present changes with the thermal treatments that it seems they depend on the variation in the implant parameters. [Spanish] Se estudian las propiedades de foto y la catodoluminiscencia de peliculas de oxidos de silicio ricos en Si (Silicon Rich Oxide SRO) obtenidas por implantacion ionica de Si en oxidos termicos. Se usaron dosis de 10{sup 1}6 cm{sup -}2 (dosis baja) y 10{sup 1}7 cm{sup -}2 (dosis alta) y energia de implantacion de 150 keV. Las peliculas se sometieron a tratamientos termicos por 30, 60 y 180 minutos en nitrogeno de 1100 grados centigrados. Se encontro emision foto y catodoluminiscente en el rango visible, las bandas en los espectros cambian con las condiciones de implantacion ionica y con los tratamientos termicos. Las peliculas sin tratamiento termico en ambas dosis presentan bandas de fotoluminiscencia alrededor de 1.9 eV (banda B) y 2.4 eV (banda C). Con los tratamientos termicos, la banda B desaparece. En el caso de las peliculas con dosis baja, la banda C muestra un corrimiento hacia el azul junto con una

  16. Comportamiento de los tejidos óseo y mucoso perimplantarios con la utilización de un sistema de implantes dentales de plataforma estrecha. Un año de seguimiento

    OpenAIRE

    Fernández Formoso, Noelia

    2012-01-01

    Se asignaron un total de 43 pacientes en dos grupos: grupo control con implantes convencionales y grupo test con implantes de plataforma estrecha. Se procedió a medir los siguientes parámetros: medición del nivel óseo y medición de los tejidos blandos. Se utilizaron dos métodos radiográficos: método convencional y la técnica modificada. Resultados: 1)nivel óseo: la pérdida de tejido óseo con plataforma estrecha mejora los resultados obtenidos con plataforma convencional, 2)tejidos blandos: me...

  17. Estudio comparativo en pacientes con implante de stent liberador de droga y stent convencional. Resultados clínicos e indicaciones

    Directory of Open Access Journals (Sweden)

    Mariano Albertal

    2006-01-01

    Full Text Available Antecedentes Estudios aleatorizados demostraron la superioridad del uso de stents liberadores de droga (SL sobre el stent convencional (SC. La información en nuestro medio sobre el implante de SL es escasa. Objetivo Comparar los resultados clínicos obtenidos en pacientes sometidos a implante de SL versus SC en un centro terciario de la Argentina. Material y métodos Se incluyeron todos los pacientes sometidos a angioplastia electiva desde abril de 2003 hasta junio de 2005 y se dividieron en dos grupos: los pacientes sometidos a implante de uno o más SL (grupo SL, n = 373 y los sometidos solamente a implante de SC (grupo SC, n = 857. Resultados Las características basales fueron similares entre los dos grupos. En el grupo SL se observó un porcentaje mayor de lesiones en la arteria descendente anterior (50,6 versus 40,6%; p 0,001, gracias a una reducción de la tasa de cirugía coronaria (1,4% versus 5,8%; p = 0,045. Conclusión El uso de SL en un centro terciario de la Argentina demostró que es seguro y, en comparación con el implante de sólo SC, dio por resultado una tasa menor de reintervención, primariamente por haber reducido la tasa de cirugía de revascularización miocárdica

  18. Regeneración ósea guiada utilizando membrana de óxido de aluminio en combinación con implantes oseointegrados Guided bone regeneration using aluminum oxide membrane in combination with osseointegrated implants

    Directory of Open Access Journals (Sweden)

    M. Isa Majluf

    2007-08-01

    Full Text Available La reabsorción ósea de los maxilares ha sido una de las mayores complicaciones al momento de rehabilitar a pacientes con implantes oseointegrados. El siguiente estudio evaluó la efectividad de la membrana de óxido de aluminio (alúmina, en la regeneración ósea de rebordes colapsados y alvéolos en los que se colocaron implantes. De un total de cinco pacientes seleccionados, se estudiaron siete sitios de los cuales tres correspondieron a un solo paciente. En cada sitio (alvéolo o reborde colapsado se colocó un implante de titanio del sistema HIS y una membrana no biodegradable de óxido de aluminio (Allumina®, la cual fue retirada a las 14 semanas. Todos los pacientes fueron sometidos al mismo procedimiento quirúrgico. La ganancia promedio en mm obtenidos en orden decreciente fue la siguiente: ANM: 1.7mm, ANME: 1.6mm, AND: 1.1mm, AV: 1.0mm, AP: 0.5mm. Los resultados radiográficos ratificaron los resultados clínicos en cuanto a neoformación ósea, observándose además una favorable densidad ósea periimplantaria. El análisis estadístico (basado en los resultados clínicos t-student fue significativo para todos los parámetros evaluados con excepción de AP.Alveolar bone loss has been a very important cause of complications in osseointegrated implant rehabilitation of edentulous patients. This paper evaluates the effectiveness of aluminum oxide membrane (Allumina in the collapsed alveolar ridge where implants were used. Seven sites were studied in 5 patients. In each of these sites a HIS implant plus a non-biodegradable oxide aluminum membrane (Allumina®, was placed for 14 weeks. All patients were treated with the same surgical protocol. The average gain (in mm obtained in decreasing order was as follows: ANM: 1.7 mm, ANME: 1.6 mm, AND: 1.1mm, AV: 1.0mm, AP: 0.5mm. The clinical results were radiographically verified and these showed bone neoformation, in addition to favorable peri-implant bone density. The t-Student statistical

  19. Estudio de la calidad de recubrimientos de hidroxiapatita sobre acero inoxidable implantable aplicados mediante proyección térmica con plasma

    OpenAIRE

    Bernal Gaona, Sandra Paola

    2013-01-01

    El objetivo de este trabajo de investigación se basó en el estudio de los parámetros del proceso de deposición de recubrimientos de hidroxiapatita sobre substratos de acero inoxidable implantable mediante el proceso de proyección térmica con plasma atmosférico, que pueden afectar de forma significativa la calidad de los recubrimientos, en cuanto a su cristalinidad y adherencia al substrato. Como parámetros a evaluar se tomaron el tamaño de grano de la hidroxiapatita, el espesor...

  20. Desarrollo tecnológico y estudio de estabilidad de tabletas de liberación inmediata de meprobamato Technological development and stability study of meprobamate immediate released tablets

    Directory of Open Access Journals (Sweden)

    Mirna Fernández Cervera

    2010-12-01

    Full Text Available Se estudió el comportamiento de diferentes variantes tecnológicas de tabletas de liberación inmediata de meprobamato (400 mg, obtenidas por granulación húmeda. El tiempo de desintegración y el porcentaje de fármaco disuelto mostraron dependencia significativa con las proporciones del lauril sulfato de sodio/croscarmelosa sódica en las formulaciones. Se evaluaron las propiedades físicas y químicas de las tabletas durante 6 meses (estabilidad acelerada y 24 meses (de vida útil, respectivamente. Se obtuvieron a partir de las formulaciones seleccionadas granulados y tabletas con propiedades organolépticas, físico-mecánicas y tecnológicas satisfactorias, lo que indicó la factibilidad del proceso de fabricación de este producto. Los resultados demostraron la buena estabilidad de las formulaciones de tabletas de liberación inmediata de meprobamato seleccionadas. La disolución in vitro no mostró diferencias significativas, por lo que ni el tiempo transcurrido ni la composición de la formulación influyeron sobre los porcentajes del fármaco disuelto. La valoración mostró diferencias significativas, sin embargo, las formulaciones evaluadas cumplieron con las especificaciones farmacéuticas oficiales durante 24 meses.The behavior of different technological variants of fast release tablets of Meprobamato (400 mg obtained by wet granulation. The desintegration time and the percentage of the dissolved drug showed a significant dependence of the sodium lauryl sulfate /sodium croscarmelose ratios present in formulae. The physical and chemical properties of tablets were assessed during 6 months (accelerated stability and dring 24 months (useful life, respectively. From the formulae selected it was possible to obtain granulates and tablets with organoleptic, physicomechanical and technological properties, demonstrating the feasibility of the process of fabrication of this product. Results showed the good stability in the immediate release

  1. Terapia de resincronización con implante de electrodo ventricular izquierdo por vía epicárdica Resynchronization therapy with left ventricular electrode implant via epicardium

    Directory of Open Access Journals (Sweden)

    Francisco Gómez

    2007-12-01

    Full Text Available Introducción: la terapia de resincronización cardiaca es segura y efectiva para mejorar la clase funcional y la calidad de vida, y reducir la mortalidad en pacientes con falla cardiaca en estado funcional III y IV con terapia médica óptima. Métodos: este es el reporte del procedimiento realizado a un grupo de pacientes a quienes se les implantó un marcapasos tricameral para resincronización cardiaca, con inserción del electrodo ventricular izquierdo por vía epicárdica, realizado en la Unidad Cardiovascular y de Trasplantes del Hospital Universitario San Vicente de Paúl y la Universidad de Antioquia, en noviembre de 2004 a febrero de 2006. Los pacientes elegidos para la inserción cumplían con los criterios de falla cardiaca estadio C o D, según la clasificación de la NYHA III ó IV, corroborado con prueba funcional menor de 5 MET, fracción de eyección menor del 35%, QRS mayor de 120 milisegundos y criterios ecocardiográficos de disincronía intraventricular, interventricular o aurículo-ventricular. Resultados: se incluyeron nueve pacientes: cinco hombres y cuatro mujeres, con edad promedio de 57 años; ocho pacientes tenían bloqueo de rama izquierda del haz de His. El procedimiento de implante se realizó en dos tiempos, el primero en la sala de hemodinámica donde se ubicó el electrodo de aurícula derecha y ventrículo derecho, y el segundo en el quirófano, donde se puso un electrodo del ventrículo izquierdo por vía epicárdica por minitoracotomía anterior izquierda. El tiempo total del procedimiento osciló entre 35 a 210 minutos con un promedio de 105 minutos, menor en los últimos pacientes. Las medidas intraoperatorias demuestran un umbral de estimulación promedio de 0,9 mv; la duración del QRS fue menor a 130 milisegundos luego de la estimulación biventricular en el 100% de los casos y el tiempo de detección al estimular con el electrodo ventricular izquierdo, fue mayor de 100 milisegundos en el 100% de los

  2. Reconstrucción inmediata de cuero cabelludo Immediate scalp reconstruction

    Directory of Open Access Journals (Sweden)

    O. Iribarren Brown

    2006-03-01

    Full Text Available Presentamos una serie de casos realizados en el Servicio de Cirugía del Hospital Clínico San Pablo en Coquimbo, Chile, entre Abril de 1998 y Abril de 2005. Se trata de un grupo de estudio de 22 pacientes consecutivos con pérdida traumática o quirúrgica del cuero cabelludo, mayor de 3cm de diámetro. Se empleó para la reconstrucción colgajo semilunar, en espejo o en remolino vascularizados a partir de las ramas principales del cuero cabelludo. Analizamos en cada caso el tamaño del defecto, pérdida de hueso asociada, tipo de cirugía, resultados de la cobertura y complicaciones. La edad media de los pacientes fue de 40.6 años con un rango entre 3 y 71 años. El área anatómica comprometida fue parietal en 11 pacientes (50%, temporal en 7 (31,8%, occipital en 3 (13,6% y frontal en 1 caso (4,5%. La causa de la pérdida de sustancia fue resección de tumores malignos o benignos en 10 casos, postraumática en 5, postquirúrgica en 4, y por alopecia en 3. El tamaño medio del defecto fue de 147 cm² con un rango entre 28 y 615 cm² . El colgajo empleado fue doble en espejo en 10 casos (50%, semilunar de deslizamiento en 9 (36,4% y en remolino en 3 (13,6%. En 6 pacientes se utilizó un injerto dermo-epidérmico para cerrar un defecto residual del área dadora del colgajo (dos semilunares y dos en espejo. Veintiun pacientes (45% evolucionaron sin incidencias, con cicatrización del colgajo en un plazo máximo de 21 días. Un paciente con pérdida ósea tras dos craneotomías, presentó necrosis parcial distal del colgajo y falleció por neumonía aspirativa. Comparamos los tres tipos de reparación de acuerdo al tamaño del defecto y a la superficie del mismo. La elección de colgajo doble en espejo, remolino o semilunar, al aplicar la prueba de Kruskal Wallis, no se relacionó con la superficie del defecto, y la elección del colgajo fue atribuible al azar, p > 0.05. La principal razón para escoger uno u otro fue la ubicación del defecto

  3. Propiedades mecánicas y degradación de implantes dentales de circona estabilizada con itria

    OpenAIRE

    Sevilla Sánchez, Pablo

    2007-01-01

    En la actualidad, el campo de la implantología se encuentra en pleno crecimiento. En pocos años han surgido numerosas empresas fabricantes de implantes dentales y la competencia es cada vez más fuerte. Por esta razón las empresas de implantes dentales apuestan por la innovación y tratan de lanzar al mercado nuevos productos a fin de aumentar su cota de mercado. En odontología la estética es uno de los factores de mayor impacto en el éxito de un tratamiento. Y por ello, cada día...

  4. Implantes cono Morse con sistema de indexación interno: Descripción del caso clínico Morse taper interface with prosthetic index: Clinical case presentation

    OpenAIRE

    G Thomé; SR Bernardes; CG Castro; AL Golin; IAM Sartori

    2011-01-01

    El empleo de implantes cono Morse con indexadores para instalación con torque interno sería una opción interesante para el diseño de un implante dentario, que incluso podría traer más opciones protéticas a ese sistema ya que el índex interno también puede utilizarse como una referencia para las restauraciones. El objetivo de este artículo es describir un caso clínico con empleo de implantes cono Morse y un sistema de indexación interno, que evitaría el uso de un montador externo que ya venga ...

  5. Las normas de aplicación inmediata en la doctrina y en el derecho positivo

    Directory of Open Access Journals (Sweden)

    Ruben B. Santos Belandro

    2015-10-01

    Full Text Available  Al modelo de Estado del siglo XVIII que asumía como únicas funciones la de juez para la solución de los litigios entre los particulares y de gendarme con el objetivo de preservar lapaz pública, le sucedió en los primeros 50 años de nuestro siglo la concepción de un Estado intervencionista -denominado también welfare state o Estado Bienestar- en el que se le otorgó una mayor atención al bienestar de sus habitantes mediante una gestión directa de numerosos sectores de la economía, al privilegio en el desarrollo de aquellas áreas más deprimidas, a la distribución intencional de los recursos sociales en favor de los desprotegidos económicamente, etc (...Contenido: La doctrina.  El derecho positivo. La doctrina uruguaya. 1985-1995. La posición de Uruguay respecto de la liberalización del comercio internacional. La Ronda Uruguay del GATT y la Organización Mundial del Comercio. Conclusiones

  6. Dosimetria “in vivo” para implantes ginecologicos de cancer de cervix, con braquiterapia de alta tasa de dosis (hdrb

    OpenAIRE

    Guillen G., Oscar O.; Duran S., Rosalia

    2009-01-01

    SOLCA Guayaquil en el Servicio de Braquiterapia dispone de un equipo de carga diferida de alta tasa de dosis, Microselectron HDR de la Empresa Nucletron, equipado con una fuente de Ir192, para la realización de tratamiento a pacientes portadores de cáncer en diferentes localizaciones. Se usa un maniquí de sólido de PMMA tipo 9193, de la PTW con el objetivo de determinar la tasa de kerma en aire de la fuente de Ir192, cuyo error no supera el 0.5%. Adicionalmente, se establece un mecanismo ...

  7. Revisión con aguja tras implante de válvula de Ahmed en la ciclitis heterocrómica de Fuchs

    Directory of Open Access Journals (Sweden)

    Francisco Y Fumero González

    Full Text Available La ciclitis heterocrómica de Fuchs es una uveítis crónica que puede ser asintomática por años o expresar solo la heterocromía antes que aparezca cualquier otro signo. El glaucoma se considera una de las complicaciones más difíciles de tratar, y requiere cirugía en múltiples ocasiones. Los dispositivos de drenaje están siendo cada vez más utilizados como alternativa de tratamiento quirúrgico en estos casos. Asiste a la consulta médica una paciente de 36 años de edad, con antecedentes de uveítis crónica unilateral del ojo izquierdo asociado a catarata y glaucoma descompensado, a pesar del tratamiento médico. Se presenta con 50 VAR de visión y presión intraocular de 32 mmHg. Se realizó cirugía combinada: facoemulsificación e implante de válvula Ahmed modelo S2 con mitomicina C (0,2 mg/mL durante cinco minutos. Se diagnostica ampolla de filtración encapsulada en la octava semana. Se realiza revisión con aguja y subconjuntival de 1 mg de bevacizumab (avastin subtenoniano en área de la filtrante. La inyección se repite días alternos hasta completar tres dosis según protocolo institucional. Se logran cifras de presión intraocular de 17 mmHg y agudeza visual mejor corregida de 95 VAR a los 18 meses posoperatorios.

  8. Sobredentadura total superior implantosoportada Superior total overdenture on implants

    Directory of Open Access Journals (Sweden)

    Luis Orlando Rodríguez García

    2010-06-01

    Full Text Available Se presenta un caso de un paciente desdentado total superior, rehabilitado en la consulta de implantología de la Clínica "Pedro Ortiz" del municipio Habana del Este en Ciudad de La Habana, Cuba, en el año 2009, mediante prótesis sobre implantes osteointegrados, técnica que se ha incorporado a la práctica estomatológica en Cuba como alternativa al tratamiento convencional en los pacientes desdentados totales. Se siguió un protocolo que comprendió una fase quirúrgica, procedimiento con o sin realización de colgajo y carga precoz o inmediata. Se presenta un paciente masculino de 56 años de edad, que acudió a la consulta multidisciplinaria, preocupado, porque se le habían elaborado tres prótesis en los últimos dos años y ninguna reunía los requisitos de retención que él necesitaba para sentirse seguro y cómodo con las mismas. El resultado final fue la satisfacción total del paciente, con el mejoramiento de la calidad estética y funcional.This is the case of a total maxilla edentulous patient seen in consultation of the "Pedro Ortíz" Clinic Implant of Habana del Este municipality in 2009 and con rehabilitation by prosthesis over osteointegration implants added to stomatology practice in Cuba as an alternative to conventional treatment in patients totally edentulous. We follow a protocol including a surgery or surgical phase, technique without or with flap creation and early or immediate load. This is a male patient aged 56 came to our multidisciplinary consultation worried because he had three prostheses in last two years and any fulfilled the requirements of retention to feel safe and comfortable with prostheses. The final result was the total satisfaction of rehabilitated patient improving its aesthetic and functional quality.

  9. Evolución de los pacientes con complicaciones locales en la bolsa del generador de un dispositivo implantable

    OpenAIRE

    Izquierdo,Maite; Bonanad,Clara; Madrazo,Inés; Ferrero,Ángel; Martínez,Ángel; Morell,Salvador; Chorro,Javier; Ruiz-Granell,Ricardo

    2014-01-01

    Objetivo: Las recomendaciones para la extracción completa de la bolsa de dispositivos implantables por problemas locales han cambiado. Analizamos la evolución entre 2002 y 2010 de los pacientes que requirieron una intervención por una complicación local en nuestro centro. Métodos: Ochenta y tres pacientes tuvieron un problema local de la bolsa que se clasificó según integridad de la piel: 1. Íntegra y 2. Abierta, y el tipo de intervención realizada: 1. Conservadora, 2. Extracción parcial y 3....

  10. Implante subcutáneo de un carcinoma hepatocelular tras la punción aspiración con aguja fina Subcutaneous seeding of hepatocellular carcinoma after fine-needle percutaneous biopsy

    Directory of Open Access Journals (Sweden)

    D. Martínez Ramos

    2007-06-01

    Full Text Available Los implantes subcutáneos son una complicación rara tras la punción aspiración con aguja fina de los carcinomas hepatocelulares. Los autores describen un caso de implante subcutáneo neoplásico en una mujer de 70 años con cirrosis hepática por virus C complicada con un carcinoma hepatocelular. Se efectuó una punción aspiración con aguja fina en el segmento II hepático. El implante tumoral se desarrolló en el trayecto de la punción aspiración. La tumoración subcutánea fue extirpada quirúrgicamente y el estudio anatomopatológico confirmó que se trataba de un carcinoma hepatocelular bien diferenciado.Subcutaneous tumor seeding after fine-needle percutaneous biopsy for hepatocellular carcinoma is a rarely seen complication. The authors describe a case of subcutaneous neoplastic seeding in a 70-year-old woman with chronic hepatitis C virus complicated by hepatocellular carcinoma. Ultrasonically guided fine-needle aspiration biopsy was performed in segment II of the liver. The neoplastic seeding developed along the needle track used to carry out the fine-needle biopsy. The subcutaneous tumor was excised, and histological examination revealed a well-differentiated hepatocellular carcinoma.

  11. Anestesia para implante de marca-passo em paciente adulto com ventrículo único não-operado: relato de caso Anestesia para implante de marcapaso en paciente adulto con ventrículo único no operado: relato de caso Anesthesia for pacemaker implant in an adult patient with unoperated univentricular heart: case report

    Directory of Open Access Journals (Sweden)

    Adriano Bechara de Souza Hobaika

    2007-02-01

    pacientes con cardiopatía congénita. Solamente 11 casos de pacientes con ventrículo único no operado y edad por encima de los 50 años, fueron relatados en la literatura. Este trabajo tiene el objetivo de describir la conducta anestésica en paciente con ventrículo único para implante de marcapaso. RELATO DEL CASO: Paciente del sexo femenino, 47 años, con doble vía de entrada del ventrículo izquierdo, L-transposición de grandes arterias y estenosis subpulmonar, sin corrección quirúrgica previa, se marcó consulta para implante de marcapaso cardíaco definitivo secuencial de dos cámaras. En el MAPA presentaba bloqueo atrioventricular de segundo grado y una frecuencia cardiaca promedio de 45bpm. Los exámenes preoperatorios mostraban hematócrito de 57%, coagulograma normal, función ventricular preservada. La monitorización constó de oxímetro de pulso, ECG en las derivaciones D II y V5, PIA, capnógrafo y analizador de gases. Un marcapaso temporal transcutáneo quedó a disposición para el caso de bradicardia intensa. La anestesia se indujo con fentanil (0.25 mg, etomidato (20 mg y atracurio (35 mg. Cuatro minutos después de la inducción, la frecuencia cardiaca disminuyó para 30bpm siendo administrado 1 mg de atropina, con reversión de la bradicardia. La anestesia se mantuvo con sevoflurano a 2.5%, aire 60% y oxígeno 40%. El estado hemodinámico y la saturación de oxígeno permanecieron estables. La paciente fue llevada a la unidad de terapia intensiva estable y extubada al final del procedimiento. CONCLUSIONES: La conducta anestésica para implante de marcapaso en paciente de 47 años con doble vía de entrada del ventrículo izquierdo y estenosis subpulmonar no operada, fue adecuada, ya que permitió la realización del procedimiento indicado.BACKGROUND AND OBJECTIVES: Single ventricle is a rare abnormality, affecting 1% of the patients with congenital cardiopathy. Only 11 cases of patients with unoperated univentricular heart older than 50 years

  12. Quantification of the vascularisation of the orbital implants of coralinehydroxyapatite with {sup 99m} Tc-MDP; Cuantificacion de la vascularizacion de los implantes orbitales dehidroxiapatita coralina con {sup 99m} Tc-MDP

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, J.L.; Solano, M.E.; Alvarez, I.; Perez, G. [Centro deInvestigaciones Clinicas 34 no.4501 e/45 y 47 Kohly, Playa C. Habana (Cuba)

    1998-12-31

    The use of ocular implants of hydroxyapatite has been increased in the last times owing to that they are well tolerated by the organism and that on the integration they show good mobility on the artificial eye with very few complications. The gammagraphy with {sup 99m} Tc-MDP can be used for the evaluation of vascularisation and its relative quantification above on these implants. In this pilot essay 10 normal persons and 37 patients were studied who had an implant of Cuban coraline hydroxyapatite (Coraline HAP-200). Thermography with {sup 99m} Tc-MDP was realized between 4 and 18 months after surgery then were obtained plane images in anterior viewing. It was measured the implant vascularisation and it was calculated for each case the relative captivation index (RCI) starting from two regions of ocular interest. As result all patients tolerated the implant without complications. The relation of the activity implant with respect to the contralateral region was 2.31{+-}0.63 (mean {+-} SD) with a range of 1.17-4.09. The relation between the left intra orbital captivation and the right in the normal persons was 1.01 {+-}0.66 (mean {+-} SD). In conclusion, we obtained that the ICR can be very useful in order to measure the integration level of this type of implant.Moreover, it was proved that the implants with Cuban coraline hydroxyapatite showed an acceptable level of integration in all the patients. (Author)

  13. Perdida ósea margina y supervivencia a cuatro años de implantes osteointegrados colocados en pacientes con síndrome de Down y parálisis cerebral

    OpenAIRE

    López Giménez, Julián

    2017-01-01

    un estudio retrospectivo de colocación de implantes en síndrome de down paralíticos cerebrales y pacientes sanos y hacer una comparativa entre los grupos y valorar la pérdida ósea marginal y el fracaso implantológico de cada grupo además valorar otras variables según la edad prótesis localización.... RESUMEN INTRODUCCIÓN & OBJETIVOS: Evaluar la tasa de supervivencia de los implantes y la pérdida ósea marginal después de 4 años en pacientes con síndrome de D...

  14. Analysis of the passive layer developed on stainless steels implanted with chromium; Analisis de las peliculas pasivas generadas en aceros inoxidables implantados con cromo

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, C. M.; Cristobal, M. J.; Novoa, X. R.; Pena, G.; Perez, M. C.

    2004-07-01

    This work studies the effect of chromium implantation on the development of passive layers generated electrochemically in alkaline medium over two stainless steels. The XPS analyses show that the layers generated on the implanted steels present less thickness together with similar composition compared to the unimplanted steels layers. However, SEM micrographs show that the layers grown on implanted steels present more defects and less adherence that the films on unimplanted steels. These changes together with the results obtained by Cyclic Voltammetry suggest an oxide structure modification, lattice structure or crystallinity state. (Author) 6 refs.

  15. Nanopartículas de plata con potenciales aplicaciones en materiales implantables: síntesis, caracterización fisicoquímica y actividad bactericida

    OpenAIRE

    Flores, Constanza Y.

    2014-01-01

    El objetivo general del presente Trabajo de Tesis fue la preparación y caracterización de superficies sólidas modificadas con nanopartículas de plata con potenciales aplicaciones en Biomedicina. Para esto se optimizó el método de síntesis de nanopartículas de plata (NPs Ag) recubiertas con citrato, obteniendo NPs Ag monodispersas de 6 ± 2 nm de diámetro recubiertas con citrato y estables en medios acuosos. Asimismo, se estudió la inmovilización de estas NPs Ag sobre superficies de Ti/TiO2, en...

  16. Vivo dosimetry using TLD detectors in prostate seed implants of I-125: preliminary results; Dosimetria in vivo mediante detectores de TLD en implantes de prostata con semillas de I-125: resultados preliminares

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Reyes, A.; Pedro, A.; Bassas, P.; Duch, M. A.; Cros, M.; Mane, S.

    2011-07-01

    We present preliminary results of a new in vivo dosimetry technique that could allow to know immediately after implantation of the prostate if the dose distribution determined by the scheduler is similar to the actual dose measured with TLD detectors.

  17. Glaucoma maligno en paciente con cirugía previa de catarata traumática e implante valvular: reporte de caso

    Directory of Open Access Journals (Sweden)

    Juan Carlos Serna-Ojeda

    2015-07-01

    Full Text Available El glaucoma maligno es un glaucoma secundario asociado con un bloqueo ciliar y dirección equivocada del flujo del humor acuoso. Se presenta el caso de un paciente masculino de 19 años con antecedente de explosión de filtro metálico en ojo derecho. Se encuentra con una presión intraocular de 52 mmHg y cristalino luxado a cámara anterior. Se inicia terapia máxima para glaucoma y se realiza facoemulsificación con posterior colocación de válvula de Ahmed, y 3 semanas después de la cirugía presenta hallazgos clínicos compatibles con glaucoma maligno. Se presenta el seguimiento del paciente y los estudios de imagen indicados

  18. Rehabilitación implantosoportada en el colgajo libre de peroné Implant-supported rehabilitation using the fibula free flap

    Directory of Open Access Journals (Sweden)

    C. Navarro Cuéllar

    2006-10-01

    Full Text Available El colgajo de peroné ha demostrado ser el más versatil para la reconstrucción oromandibular, gracias a la gran longitud ósea que podemos utilizar y a la posibilidad de incorporar una amplia paleta cutánea para cobertura de tejidos blandos intraorales. El uso de implantes dentales osteointegrados proporciona un importante método terapéutico para la rehabilitación oral de estos pacientes. Los implantes osteointegrados proporcionan la forma más rígida de estabilización protésica para soportar las fuerzas masticatorias. Estos implantes pueden ser insertados de forma inmediata o diferida. A la hora de utilizar el colgajo libre de peroné realizamos la implantología de forma diferida a los 6-12 meses debido a la gran cantidad de material de osteosíntesis necesaria para la fijación del colgajo. Cuatro o seis meses después, cuando el proceso de osteointegración ha ocurrido, los implantes son cargados con una rehabilitación dental. Analizamos 12 casos de reconstrucción mandibular con colgajo libre de peroné y su rehabilitación estética y funcional con implantes osteointegrados y un seguimiento mínimo de 2 años. Se han colocado un total de 56 implantes, presentando todos ellos excepto uno, una correcta osteointegración. Todos estos pacientes han recuperado la función masticatoria, y mejorado de forma considerable la competencia labial, la continencia salival, la pronunciación y la armonía facial.Free fibula flap has proved to be one of the most versatile for oromandibular reconstruction due to the available length of bone and the possibility of incorporating a long skin paddle to cover intraoral soft tissues. The use of osseointegrated dental implants is an important technique for the oral rehabilitation of these patients. Osseointegrated implants provide the most rigid prosthetic stabilization available to withstand masticatory forces.These implants can be placed immediately or in a second time procedure.In our case

  19. Protocol updated for the treatment of patients in radiotherapy with implanted cardiac devices; Protocolo actualizado para el tratamiento de pacientes en radioterapia con dispositivos cardiacos implantados

    Energy Technology Data Exchange (ETDEWEB)

    Martin Martin, G.; Bermudez Luna, R.; Rodriguez Rodriguez, C.; Lopez Fernandez, A.; Rodriguez Perez, A.; Sotoca Ruiz, A.

    2013-07-01

    Radiotherapy treatment can be safely performed in patients with pacemakers or implanted defibrillators, however, it is very important to ensure that the patient receives the minimum dose possible in your heart device. Is considered essential good coordination with the cardiology service before, during and after radiotherapy treatment for the patient safety. Finally we present a protocol updated to treat these patients in radiotherapy. (Author)

  20. Immediate adverse reactions to intravenous iodinated contrast media in computed tomography Reacciones adversas inmediatas al contraste yodado intravenoso en tomografía computarizada Reações adversas imediatas ao contraste iodado intravenoso em tomografia computadorizada

    Directory of Open Access Journals (Sweden)

    Beatriz Cavalcanti Juchem

    2007-02-01

    Full Text Available This exploratory-descriptive, non-experimental quantitative research aimed to learn about immediate adverse reactions to intravenous iodinated contrast media in hospitalized patients submitted to computed tomography at a teaching hospital in the South of Brazil. During the study period, all adverse reactions showed mild intensity, at a frequency of 12.5% with ionic iodinated contrast media, and 1% with non-ionic contrast agent. The extravasation of contrast occurred in 2.2% of the injections in a peripheral vein without complications in any of the cases. The results are within the limits cited in international literature and suggest that tomography service professionals should know their own rates of adverse reactions to iodinated contrast agent, as well as the conditions in which they occur, in order to obtain evidence to evaluate the respective care delivery processes.Investigación cuantitativa del tipo exploratorio-descriptivo, de carácter no experimental. El objetivo consistía en conocer las reacciones adversas inmediatas al contraste yodado intravenoso en pacientes internados, sometidos a tomografía computarizada en un hospital escuela del sur de Brasil. Durante el período del estudio, todas las reacciones adversas tuvieron intensidad leve y una frecuencia del 12,5% con la utilización del contraste yodado iónico, y 1% con contraste no iónico. La extravasación del contraste ocurrió en un 2,2% de las inyecciones en vena periférica, no ocasionando complicaciones en ninguno de los casos. Los índices evidenciados en el presente estudio se mantuvieron dentro de los límites que constan en la revisión de literatura y, entre las recomendaciones, se sugiere que los servicios de tomografía conozcan los propios índices de reacciones adversas al contraste yodado y las condiciones en que ocurren, con la finalidad de obtener evidencias para evaluación de los respectivos procesos asistenciales.Pesquisa quantitativa, explorat

  1. The usefulness of the nuclear cardiology in the cellular implant in patients with severe myocardial damage; La utilidad de la cardiologia nuclear en el implante celular en pacientes con dano miocardico severo

    Energy Technology Data Exchange (ETDEWEB)

    Omelas A, M.; Arguero S, R.; Garrido G, M.H.; Rodriguez C, A.; Careaga, G.; Castano G, R.; Nambo, M.J.; Pascual P, J.; Ortega R, A.; Gaxiola A, A.; Magana S, J.A.; Estrada A, H.; Equipo de Tecnicos en Medicina Nuclear [Centro Medico Nacional Siglo XXI IMSS Hospital de Cardiologia-Servicio de Medicina Nuclear Mexico DF (Mexico)

    2005-07-01

    The recent therapeutic advances as the cellular implant as well as those different protocols of image acquisition in the field of the Nuclear Cardiology its have allowed that the patient with severe myocardial damage and without some possibility of revascularization is benefited with these advances. Doubtless the Tl-201 par excellence has an important paper for standardize the more appropriate therapeutic behavior for the heart attack patient; reason by this investigation protocol was developed. The objective of the study was to identify the heart attack regions without viable tissue with SPECT in patient with important myocardial damage without some possibility of traditional revascularization; for the 'Stem cell' cellular implantation therapy. The methodology it was carried out by a study of myocardial perfusion in 10 patients with important myocardial damage previous cellular implants, with PICANUC/ SPECT methodology and using a software (Emory Tool Box) for the image processing validated by the University of Emory Atlanta GA; and using as tracer the Tl - 201 to identify the heart attack regions without presence of viable tissue with an analysis model of 17 segments standardized for the left ventricle; qualifying this way the myocardial perfusion in: 0 (normal), 1 (light), 2 (moderate), 3 (severe), 4 (absent) and x (bad technique). The conclusions were that the SPECT study with PICANUC methodology with Tl-201 is safe and effective for the precise localization for the cellular implantation via direct intra myocardial. (Author)

  2. Implante de la válvula aórtica Perceval S® en un paciente con endocarditis aórtica

    Directory of Open Access Journals (Sweden)

    José Ramón González Rodríguez

    2015-05-01

    Conclusiones: El uso de la válvula aórtica protésica sin sutura “Perceval S”, es una posibilidad terapéutica para el tratamiento de la endocarditis aórtica aguda en casos con destrucción parcial anular y subanular.

  3. Colocación de implantes en zonas atróficas. Técnica con osteótomos : Reporte de caso clínico

    OpenAIRE

    Tomaghelli, Emanuel Ricardo

    2016-01-01

    La atrofia vestíbulo-palatina sufrida en el maxilar superior es uno de los desafios estéticos más importantes en cuanto a la planificación de una restauración implanto asistida. Los colapsos vestibulares dificultan no solo la correcta colocación de implantes, estética gingival y arquitectura de las restauraciones protéticas. La técnica quirúrgica, cuando la pérdida ósea es leve a moderada, muchas veces puede ser solucionada utilizando instrumentos de expansión creados por Summers, 1994 llamad...

  4. Treatment of prostate adenocarcinoma permanent implants with I 125: first experience in Uruguay; Tratamiento del adenocarcinoma de prostata con implantes permanentes de I125: primera experiencia en el Uruguay

    Energy Technology Data Exchange (ETDEWEB)

    Quarneti, A.; Clark, O.; Glaussius, A.; Kaitasoff, P.; Cosia, G.

    2010-12-15

    Full text: Objective: To report on the treatment done, toxicity and development of a group of adenocarcinoma patients with localized prostate brachytherapy implants permanent I125. Material and Methods. 37 patients were treated in the period 2001 to 2004 at the Military Hospital Central by this treatment modality. All of them were performed before implantation planning, which consisted of the volumetric calculation and calculation prostate dosimetry that included transrectal prostate ultrasound 3-5 weeks before the procedure. all patients had pathological confirmation of the lesion showed PSA values less than 11 ng / ml and Gleason score less than 7. 70% of patients received neo-adjuvant hormone therapy. In 5 patients an interactive planning system was performed computerized dosimetry, using sequential ultrasound imaging planes, allowed the dosimetric analysis before terminate the procedure and make necessary adjustments if the dose distribution did not conform. This additional dosimetric study we have not been described by other authors. Prescribed in the first 10 patients was dose 144 Gy and 160 Gy in subsequent. All patients underwent post implant CT waffle grid after 15 days of the procedure. analyzed the dose volume histogram (HDV) and D90 values??. Clinical follow-up was performed and PSA biochemical .. Preliminary Results: 33 patients were in local control without biochemical failure. Currently 4 patients presented biochemical recurrence with PSA values ??between 4 and 6 ng / ml. In neither disease was found at a distance and then raises confirmation tumor biopsy active presence will undergo surgical treatment protocols localized prostate cancer. HDV values ??D90 and are consistent with the informed by the international literature will be presented. No patient required hospitalization prolonged (greater than 24 hours) or use of higher analgesics. 2 patients had acute urinary retention (G II complication) between the tenth and twentieth day, the rest of the

  5. Bacilos Gram negativos entéricos y no fermentadores de la glucosa en pacientes con enfermedad periimplante

    Directory of Open Access Journals (Sweden)

    Jessika Consuegra

    2011-04-01

    Conclusiones. Un tercio de los implantes estudiados presentaron organismos sobreinfecciosos. Los implantes con lesiones periimplante presentan una mayor frecuencia de bacterias sobreinfecciosas. K. pneumoniae es la especie sobreinfecciosa más frecuente en los implantes estudiados. Se presentó infección múltiple con dichas bacterias en los implantes afectados. Estos microorganismos pueden afectar la estabilidad de los implantes.

  6. Dosimetric results in implant and post-implant and low rate in brachytherapy prostate cancer with loose seeds and attached; Resultados dosimetricos en el implante y post-impante en braquiterapia de baja tasa en cancer de prostata con semillas sueltas y unidas

    Energy Technology Data Exchange (ETDEWEB)

    Juan-Senabre, X. J.; Albert Antequera, M.; Lopez-Tarjuelo, J.; Santos Serra, A.; Perez-Mestre, M.; Sanchez Iglesias, A. L.; Conde Moreno, A. J.; Gonzalez Vidal, V.; Beltran Persiva, J.; Muelas Soria, R.; Ferrer Albiach, C.

    2015-07-01

    The objective is determine differences dosimetry statistics on the dosimetry of the implant and post-implant in brachytherapy of low rate with implants permanent in prostate using seed of 125-I loose and attached Both in lives and in the post-prostatic plans dosimetric coverage is good and restrictions in urethra and rectum for both groups of patients are met. Not migrating with joined is evident, as well as better dosimetric homogeneity. (Author)

  7. Estimulación temprana y desarrollo lingüístico en niños sordos con Implante coclear: el primer año de experiencia auditiva

    Directory of Open Access Journals (Sweden)

    Ignacio Moreno-Torres

    2011-06-01

    Full Text Available Este estudio analiza el desarrollo de un grupo de 10 niños sordos a los que se ha colocado un implante coclear (IC antes de los dos años. El objetivo es comprobar en qué medida el desarrollo post-IC se ve afectado por el grado de estimulación temprana recibida. Se obtienen datos de percepción (cuestionario parental, y producción lingüística y prelingüística (vídeos de producción espontánea y cuestionarios. Además, se realizó una valoración del grado de estimulación recibido pre y post-implante. Los resultados muestran grandes diferencias intra-grupo: 1 en el ritmo de desarrollo lingüístico (léxico productivo a los 12 meses de experiencia auditiva; y 2 en el grado de estimulación. El análisis estadístico mostró que el grado de estimulación a los 12 meses es el único factor de los estudiados que correlaciona con el desarrollo lingüístico tras 12 meses. No correlacionan: edad al implantarse, percepción a los tres meses, ni balbuceo canónico. Tales resultados confirman la gran importancia del entorno, y en particular de la familia, en la rehabilitación del niño implantado.

  8. Ion implantation

    International Nuclear Information System (INIS)

    Dearnaley, Geoffrey

    1975-01-01

    First, ion implantation in semiconductors is discussed: ion penetration, annealing of damage, gettering, ion implanted semiconductor devices, equipement requirements for ion implantation. The importance of channeling for ion implantation is studied. Then, some applications of ion implantation in metals are presented: study of the corrosion of metals and alloys; influence or ion implantation on the surface-friction and wear properties of metals; hyperfine interactions in implanted metals

  9. Características clínico-epidemiológicas de pacientes con cólera en la ciudad de México

    OpenAIRE

    Vilchis-Guizar Agustina Elena; Uribe-Márquez Samuel; Pérez-Sánchez Patricia Leonor

    1999-01-01

    OBJETIVO: Comparar las características clínico-epidemiológicas de enfermos de cólera (casos) con las de pacientes con diarrea por otra causa (no casos), atendidos en las unidades médicas de la Delegación 2 Noreste del Distrito Federal, del Instituto Mexicano del Seguro Social (IMSS). MATERIAL Y MÉTODOS: Se realizó un estudio transversal analítico y se utilizaron datos de 4 952 notificaciones reunidas entre 1995 y 1998 a través del formato oficial "Hoja de notificación inmediata de casos de có...

  10. Calidad visual en pacientes con lente intraocular multifocal modelo OcuFlex operados de catarata The quality of vision in patients operated on from cataract and implanted with OcuFlex multifocal intraocular lenses

    Directory of Open Access Journals (Sweden)

    Eneida Pérez Candelaria

    2010-01-01

    Full Text Available OBJETIVO: Describir la calidad visual en 8 pacientes operados de catarata bilateral con la técnica de Faco-chop e implante de lente intraocular multifocal modelo OcuFlex, en el ICO "Ramón Pando Ferrer", desde septiembre 2007 a febrero 2008. MÉTODOS: Se realizó un estudio observacional, descriptivo, longitudinal y prospectivo para lo cual se analizaron variables como equivalente esférico, sensibilidad al contraste en el preoperatorio y posoperatorio; fenómenos visuales, centrado y localización del lente intraocular, así como el estado de satisfacción subjetiva de los pacientes. Se utilizó la estadística descriptiva con ayuda del sistema Microsoft Excel y Word 2003, para Windows XP. RESULTADOS: El equivalente esférico medio posoperatorio fue -0,59 tanto para frecuencias bajas como medias, en visión binocular la sensibilidad al contraste media fue de 1,12 unid.log en el preoperatorio y de 1,74 unid.log. en el posoperatorio. Por biomicroscopia con lámpara de hendidura en el 100 % de los casos el lente intraocular estaba centrado y por biomicroscopia ultrasónica el 93,75 % se encontraba en el saco capsular. Ningún paciente refirió la presencia de glare y solamente uno (12,5 % reportó visión de halos nocturnos. La totalidad de los pacientes se manifestaron satisfechos. CONCLUSIONES: Los lentes multifocales disminuyen la dependencia de las gafas después de la cirugía de catarata, razón por la que constituye una buena opción en la recuperación de la función visual óptima.OBJECTIVE: To describe the quality of vision in 8 patients, who were operated on from bilateral cataract using Phaco-chop technique and implanted with Ocuflex multifocal intraocular lens in "Ramón Pando Ferrer" Cuban Institute of Ophthalmology from September 2007 to February 2008. METHODS: A prospective, longitudinal, observational and descriptive study was made in which the variables spheral equivalent, contrast sensitivity in the pre- and post

  11. Calidad de las relaciones familiares, su relación con la salud y conductas de riesgo en adolescentes = Quality of family relations, its relation to health and at-risk behaviour in adolescents

    OpenAIRE

    Sánchez López, Mª Cristina; Parra Martínez, Joaquín; Rosa Alcázar, Ana Isabel

    2004-01-01

    El estudio que presentamos en este artículo tiene como propósito general el análisis de la relación existente entre la calidad de las relaciones de los adolescentes con su familia inmediata, la salud entendida de dos modos: salud física y salud psicológica, y el consumo de sustancias adictivas para la salud. Para ello los participantes fueron 170 sujetos de ambos géneros con edades comprendidas entre 14 y 20 años. Los resultados muestran que existen relaciones significativas entre los constru...

  12. Características clínico-epidemiológicas de pacientes con cólera en la ciudad de México Clinical and epidemiological characteristics of cholera patients in Mexico City

    OpenAIRE

    Agustina Elena Vilchis-Guizar; Samuel Uribe-Márquez; Patricia Leonor Pérez-Sánchez

    1999-01-01

    OBJETIVO: Comparar las características clínico-epidemiológicas de enfermos de cólera (casos) con las de pacientes con diarrea por otra causa (no casos), atendidos en las unidades médicas de la Delegación 2 Noreste del Distrito Federal, del Instituto Mexicano del Seguro Social (IMSS). MATERIAL Y MÉTODOS: Se realizó un estudio transversal analítico y se utilizaron datos de 4 952 notificaciones reunidas entre 1995 y 1998 a través del formato oficial "Hoja de notificación inmediata de casos de có...

  13. Comparación de la eficacia y seguridad de la terapia combinada de cardiomioplastia celular con el factor estimulante de colonias de granulocitos en pacientes con cardiopatía isquémica en dos vías de implatación Comparison of efficacy and safety of combined therapy of cellular cardiomyoplasty and granulocyte colony stimulating factor in patients with ischemic cardiomyopathy in two routes of implantation

    Directory of Open Access Journals (Sweden)

    Juan M Senior

    2011-04-01

    ía sostenida de la fracción de eyección y los MET más allá de los beneficios que se logran con la revascularización y la terapia farmacológica óptima.The objective of this study is to assess efficacy and safety of combined therapy of cellular cardiomyoplasty and granulocyte colony stimulating factor in patients with ischemic cardiomyopathy and explore possible differences between the implantation routes. METHODOLOGY: we performed a before and after study for longitudinal data comparing echocardiographic variables and number of Met achieved in the stress test before and at two, six and twelve months after the procedure. Likewise, mortality and adverse therapy effects were evaluated. Differences in the results were analyzed according to the intracoronary vs. epicardiac route of implantation. RESULTS: eighteen patients were included; 62,3% men, with mean age 49.4 ± 11,7 years. Mean ejection fraction was 31% ± 0,04. In twelve patients implantation was performed by intracoronary route and in six by epicardiac route. Mean ejection fraction before cell implantation was 30% with an interquartil range (IQR of 28-35%, and MET average was 6 with an interquartil rage of 5-7. Both variables as well as end-systolic and end-diastolic volumes increased significantly after the procedure, with a tendency to greater increase in ejection fraction in the group of patients whose route was epicardial implantation compared with intracoronary route; however, the number of patients in each subgroup prevented to make a definitive analysis. One patient had surgical wound infection and three died two months after implantation (one of septic shock and two of cardiogenic shock. CONCLUSION: in our environment the performance of combination therapy with cellular cardiomyoplasty and granulocyte colony stimulating factor is feasible. This is a safe procedure that achieved a sustained improvement in ejection fraction and MET beyond benefits achieved with revascularization and optimal pharmacological

  14. Cambio climático: inundaciones y desarrollo : Fondo especial permanente para respuestas inmediatas en caso de emergencias y desastres naturales en la provincia de Buenos Aires

    OpenAIRE

    Tabieres, María Susana

    2017-01-01

    En el presente trabajo, se analizan las causas ambientales determinantes en la generación de inundaciones y los efectos que las mismas han producido en distintas regiones de nuestro país. Se analizan las normas emanadas del gobierno de la Provincia de Buenos aires, para prevenir y auxiliar a los sectores afectados por las inundaciones y finalmente se concluye con la enunciación de algunas medidas de orden social económico y fiscal, de posible aplicación para acompañar el proceso de protección...

  15. Cochlear Implants

    Science.gov (United States)

    ... implant, including: • How long a person has been deaf, •The number of surviving auditory nerve fibers, and • ... Implant, Severe Sensoryneurial Hearing Loss Get Involved Professional Development Practice Management ENT Careers Marketplace Privacy Policy Terms ...

  16. Diferencias en los Procesos de Atención y Memoria en Niños con y sin Estrés Postraumático

    Directory of Open Access Journals (Sweden)

    Mara Bernate-Navarro

    2009-01-01

    Full Text Available Esta investigación indagó sobre las diferencias de atención selectiva y alternante así como de la memoria inmediata y lógica en niños con o sin estrés postraumático (PTSD. La muestra estuvo conformada por un grupo control de 15 niños (8 a 10 años y un grupo experimental de 15 niños víctimas de abuso sexual con diagnóstico de PTSD (8 a 10 años. La atención se evaluó con dos subpruebas del WISC-R y el Test de Percepción de Diferencias; la memoria se evaluó por medio de dos subpruebas del Diagnóstico Neuropsicológico Infantil de Luria. A partir de los análisis realizados a través de la prueba F de Fisher, se comprobó la hipótesis de trabajo, afirmando que existen diferencias significativas a un alfa = 0,05 en los procesos de atención selectiva y alternante así como en la memoria inmediata y lógica entre los grupos, siendo todas las ejecuciones del grupo control superiores.

  17. Miragel implant, apropos of 3 cases

    OpenAIRE

    Rodríguez Rodríguez, Beatriz; García Ferrer, Laine; Cheong Quiala, Mayelin; Gallar Gutiérrez, Yolescy; Pozo Correa, Susel

    2013-01-01

    Se exponen las consecuencias a largo plazo del uso del implante de miragel como tratamiento del desprendimiento de retina. Se presentan las características durante la cirugía y el postoperatorio de la explantación de este tipo de implante en 3 pacientes que acudieron a la consulta de Retina del Hospital Oftalmológico «Amistad Argelia Cuba» en Djelfa, Republica Popular y Democrática de Argelia, con el diagnóstico de cirugía convencional de retina con implante de miragel realizado en Francia en...

  18. Ion implantation

    International Nuclear Information System (INIS)

    Johnson, E.

    1986-01-01

    It is the purpose of the present paper to give a review of surface alloy processing by ion implantation. However, rather than covering this vast subject as a whole, the survey is confined to a presentation of the microstructures that can be found in metal surfaces after ion implantation. The presentation is limited to alloys processed by ion implantation proper, that is to processes in which the alloy compositions are altered significantly by direct injection of the implanted ions. The review is introduced by a presentation of the processes taking place during development of the fundamental event in ion implantation - the collision cascade, followed by a summary of the various microstructures which can be formed after ion implantation into metals. This is compared with the variability of microstructures that can be achieved by rapid solidification processing. The microstructures are subsequently discussed in the light of the processes which, as the implantations proceed, take place during and immediately after formation of the individual collision cascades. These collision cascades define the volumes inside which individual ions are slowed down in the implanted targets. They are not only centres for vigorous agitation but also the sources for formation of excess concentrations of point defects, which will influence development of particular microstructures. A final section presents a selection of specific structures which have been observed in different alloy systems. (orig./GSCH)

  19. Factores relacionados con el éxito o el fracaso de los implantes dentales colocados en la especialidad de Prostodoncia e Implantología en la Universidad de La Salle Bajío

    Directory of Open Access Journals (Sweden)

    Jonathan E. Balderas Tamez

    2017-04-01

    Conclusiones: Según los datos recabados en esta investigación, se observó que los factores de riesgo para el fracaso en implantes son el tabaquismo, la poca o nula estabilidad primaria y la cirugía sin colgajo.

  20. Desfechos clínicos por região geográfica em pacientes com implante de stent eluidor de Zotarolimus Desenlaces clínicos por región geográfica en pacientes con implante de Stent liberador de Zotarolimus Clinical outcomes by geographic region for patients implanted with the zotarolimus-eluting stent

    Directory of Open Access Journals (Sweden)

    Chaim Lotan

    2011-05-01

    Full Text Available FUNDAMENTO: Diferenças entre regiões geográficas em relação à características de pacientes e desfechos, particularmente em síndromes coronarianas agudas, tem sido demonstradas em testes clínicos. Os desfechos clínicos após intervenções coronarianas percutâneas com o stent eluidor de Zotarolimus em uma população real foram analisados com o tempo. OBJETIVO: A influência da localização geográfica sobre os desfechos clínicos com o stent eluidor de Zotarolimus foi avaliada em três regiões: Pacífico Asiático, Europa e América Latina. MÉTODOS: Um total de 8.314 pacientes (6.572 da Europa, 1.522 do Pacífico Asiático e 220 da América Latina foram acompanhados por 1 ano; 2.116 desses (1.613, 316, e 187, respectivamente foram acompanhados por 2 anos. Características dos pacientes e lesões, terapia antiplaquetária dupla e desfechos clínicos foram comparados entre a América Latina e as outras duas regiões. RESULTADOS: Os pacientes da América Latina apresentavam a maior proporção de fatores de risco e infarto do miocárdio prévio. O uso da terapia antiplaquetária dupla declinou rapidamente na América Latina, de 44,9% em 6 meses para 22,5% em 1 ano e 7,8% em 2 anos (Europa: 87,4%, 61,5%, 19,7%; Pacífico Asiático: 82,4%, 67,0%, 45,7%, respectivamente. Não houve diferenças significantes entre a América Latina e a Europa ou Pacífico Asiático para qualquer desfecho em qualquer ponto do tempo. A incidência de trombose de stent provável e definitiva pelo Academic Research Consortium foi baixa (FUNDAMENTO: Las diferencias entre las regiones geográficas en relación con las características de pacientes y desenlaces, sobre todo en los síndromes coronarios agudos se ha demostrado en ensayos clínicos. Los desenlaces clínicos después de las intervenciones coronarias percutáneas con stent liberador de zotarolimus en una población real se analizaron a través del tiempo. Objetivos: La influencia de la ubicaci

  1. Carmustine Implant

    Science.gov (United States)

    ... works by slowing or stopping the growth of cancer cells in your body. ... are pregnant, plan to become pregnant, or are breast-feeding. If you become pregnant while receiving carmustine implant, call your doctor. Carmustine may harm the fetus.

  2. Cochlear Implants

    Science.gov (United States)

    ... NIDCD A cochlear implant is a small, complex electronic device that can help to provide a sense ... Hearing Aids Retinitis Pigmentosa - National Eye Institute Telecommunications Relay Services Usher Syndrome Your Baby's Hearing Screening News ...

  3. El efecto de los cursos con las TIC en el funcionamiento y bienestar social

    Directory of Open Access Journals (Sweden)

    Deisy Acosta Ham

    2010-04-01

    Full Text Available Cuando se es madre de un niño con necesidades educativas especiales (NEE, se vive una serie de etapas negativas que afectan a toda la familia, pero significativamente al niño especial, cuando no se dispone de la orientación y ayuda adecuadas. Las madres, al brindar atención de tiempo completo a su hijo con NEE, hacen infuncionales sus relaciones sociales; en otras palabras, sus escalas de función y bienestar social, relacionadas con la salud, son afectadas de modo negativo. Las tecnologías de información y comunicación (TIC aparecen en este escenario para brindar información y apoyo con programas educativos, comunidades virtuales, foros, y canales de conversación que proporcionan servicios psicopedagógicos, terapia, cursos de orientación, crecimiento personal y profesional. Las TIC otorgan ayuda inmediata, comunicación y acceso a información ilimitada. ¿Cómo saber si estas tecnologías están teniendo algún efecto en el aspecto social de las madres? De ahí que el propósito del presente trabajo sea conocer si existe o no dicho efecto.

  4. Desfibrilador automático implantado en pacientes con miocardiopatía hipertrófica: criterios de selección, evolución y predictores de terapia apropiada Automatic defibrillator implanted in patients with hypertrophic myocardiopathy: selection criteria, evolution and appropriate therapy predictors

    Directory of Open Access Journals (Sweden)

    Guillermo Mora

    Full Text Available Introducción y objetivos: la miocardiopatía hipertrófica es una enfermedad de origen genético con prevalencia de 1% al 2%. La mitad de los pacientes fallecen por muerte súbita cardiaca, la mayoría por arritmias ventriculares. Todavía no está claro a qué pacientes se les debe implantar un desfibrilador automático. El objetivo de este trabajo es describir una serie de pacientes con implante, los criterios empleados y los resultados obtenidos, así como analizar los predictores de terapia apropiada por el desfibrilador. Métodos: se incluyeron 20 pacientes que recibieron un desfibrilador de tercera generación. En todos se realizó estudio electrofisiológico y seguimiento prospectivo con registro de eventos. En 18 (90% se hizo estudio genético. Resultados: el 55% eran hombres con edad promedio de 40 [11-78] años. Seis (30% recibieron implantante por prevención secundaria y 14 (70% por prevención primaria; los últimos por presentar varios factores de riesgo. Se indujo una arritmia sostenida en 15 (75% y en 3 (15% taquicardia ventricular monomórfica sostenida. A 22 meses de seguimiento 4 (20% sufrieron terapia apropiada y 2 (10% fallecieron. La taquicardia ventricular monomórfica clínica (p=0,03 y la inducida (pIntroduction and objectives: hypertrophic myocardiopathy is a genetic entity with 1% to 2% prevalence. Half patients die of sudden cardiac death, most due to ventricular arrhythmias. There is still no clarity with regard to the patients to whom an automatic defibrillator has to be implanted. The objective of this work is to describe a series of patients with implant, the criteria used and the results obtained, as well as to analyze the predictors of appropriate therapy with the defibrillator. Methods: 20 patients that received a third generation defibrillator were included. Electrophysiological study and prospective follow-up with register of events was performed in all. Genetic study was done in 18 (90%. Results: 55% were

  5. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    The implantation and sputtering mechanisms which are relevant to ion bombardment of surfaces are described. These are: collision, thermal, electronic and photon-induced sputtering. 135 refs.; 36 figs.; 9 tabs

  6. EL BUMERÁN DE LOS DESEOS EN LA ÉPOCA DE LA SATISFACCIÓN INMEDIATA O BUMERANGUE DOS DESEJOS NA ÉPOCA DA SATISFAÇAO IMEDIATA THE BOOMERANG OF DESIRES IN THE EPOCH OF IMMEDIATE SATISFACTION

    Directory of Open Access Journals (Sweden)

    Fabio Ciaramelli

    2001-01-01

    Full Text Available Para combatir el riesgo de una globalización de la nocividad alimentaria es indispensable reflexionar sobre las dimensiones socio-culturales y psíquicas del consumismo, cuyas premisas son el imperativo de la satisfacción inmediata de los deseos. Partiendo de la tesis de que la multiplicación de los deseos y del anuncio de su cabal realización provoca inevitablemente la inflación de los mismos, el artículo analiza el síndrome de las vacas locas como punta de un iceberg y banco de prueba de nuestra relación con el consumo alimenticio. En este sentido la cuestión de la seguridad como ansia de impunidad colectiva no implica solamente la búsqueda de remedios eficaces contra los posibles contagios alimenticios, sino que impone, en primer lugar, esclarecer las consecuencias destructivas de una forma de vida humana en la que todo se reduce al consumoPara combater o risco de uma globalização perniciosa da produção de alimentos é indispensável refletir sobre as dimensões socioculturais e psíquicas do consumismo, cujas premissas repousam sobre o imperativo da satisfação imediata de desejos. Partindo da tese que a multiplicação dos desejos e suas realizações imediatas provoca superestimação dos mesmos, o artigo analisa a síndrome da vaca louca como ponta de um iceberg e prova cabal de nossa relação com o consumo alimentar. Nesse sentido a questão da segurança como premissa coletiva não implica simplesmente na busca de soluções eficazes contra possíveis contágios alimentares, mas sobretudo esclarecer as conseqüências deletéreas de uma forma de vida em que tudo se reduz ao consumoIn fighting against the risk of the globalization of hazardous food production it is essential to think about psico-socio-cultural dimensions of consumerism, whose premises rest on the imperative of immediate satisfaction of desires. Departing from the thesis that multiplication of desires along with their complete and immediate fulfillment

  7. Hip Implant Systems

    Science.gov (United States)

    ... Implants and Prosthetics Metal-on-Metal Hip Implants Hip Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hip implants are medical devices intended to restore mobility ...

  8. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...

  9. Implantes dentales en pacientes adultos postrauma dentoalveolar. Estudio descriptivo

    Directory of Open Access Journals (Sweden)

    Edgardo González

    2016-04-01

    Conclusiones: En este estudio se presenta un protocolo establecido y se establece la necesidad de un diagnóstico detallado para planificar la rehabilitación mediante implantes dentales posterior a un trauma con un equipo multidisciplinario.

  10. Reconstrucción cervical tras resección de neurofibroma solitario gigante con colgajo anterolateral de muslo

    Directory of Open Access Journals (Sweden)

    Mauricio Mendieta-Espinosa

    Full Text Available Los tumores de cabeza y cuello son un grupo heterogéneo; los neurofibromas pueden originarse de cualquier nervio independientemente de su localización, incluyendo nervios periféricos o intracraneales y se dividen en 4 tipos. Los solitarios son tumores confinados, espontáneos y prácticamente sin ninguna manifestación. Anatómicamente, los neurofibromas del cuello son relativamente raros, con un crecimiento lento e indoloro. Presentamos el caso de un paciente varón de 41 años de edad, remitido a nuestra consulta por presentar neurofibroma solitario gigante en la base del lado izquierdo del cuello, de 10 cm de diámetro, con zona central ulcerada y sangrados intermitentes, adherido a planos profundos, de 30 años de evolución y que había sido tratado en 3 ocasiones con resecciones parciales y cubertura con colgajo acromial. Practicamos resección completa de la tumoración y reconstrucción inmediata con colgajo anterolateral de muslo, logrando la mejoría estético-funcional de la zona cervical y sin complicaciones.

  11. Uso rutinario del balón de contra-pulsación aórtica preoperatorio en pacientes con enfermedad del tronco común izquierdo sometidos a cirugía de revascularización coronaria Routine use of preoperative intra-aortic balloon pump counterpulsation (IABP implantation in patients with left main coronary artery disease undergoing coronary revascularization surgery

    Directory of Open Access Journals (Sweden)

    Andrés Fernández

    2008-08-01

    Full Text Available Generalidades: la enfermedad del tronco común izquierdo como único criterio para la colocación de balón de contra-pulsación aórtica, es una indicación cuya evidencia se limita a la recomendación de expertos y, por lo tanto, se requieren estudios que puedan aportar mayor nivel de evidencia al respecto. Por este motivo, en nuestra institución se desarrolló un estudio que evaluó la experiencia del uso de balón de contra-pulsación aórtica preoperatorio, en pacientes sometidos a cirugía de revascularización cardiaca electiva, con enfermedad del tronco común izquierdo. Objetivo: describir la letalidad, el tiempo de estancia y el porcentaje de infecciones y sepsis en la unidad de cuidados intensivos, así como el tiempo de ventilación mecánica, en los pacientes sometidos a cirugía de revascularización coronaria electiva con y sin el uso preoperatorio de balón de contra pulsación aórtica. Métodos: estudio descriptivo retrospectivo, que se llevó a cabo en la Clínica Cardiovascular Santa María, con los pacientes que se sometieron a revascularización coronaria quirúrgica electiva acompañados o no de balón de contra-pulsación aórtica preoperatorio entre 1999 y 2003, y en el que se observó el comportamiento post-operatorio de los pacientes con enfermedad severa del tronco común izquierdo (entendida como estenosis mayor de 50% sometidos a dicha intervención. Resultados: se analizaron en total 79 pacientes sometidos a revascularización quirúrgica electiva, a 46 de los cuales se les implantó balón preoperatorio y a 33 se les practicó intervención quirúrgica sin balón. El promedio de edad fue de 62 años. El 67,4% de los pacientes tenía 60 años o más. Las principales patologías previas a la cirugía fueron hipertensión arterial (67% e infarto agudo del miocardio antiguo, (59%. 87% de los pacientes con balón y 45,5% de aquellos sin éste, tenían angina severa (clase III antes de la cirugía. En la unidad de

  12. Suspensión retropúbica en mujeres con incontinencia urinaria de esfuerzo

    Directory of Open Access Journals (Sweden)

    Amparo Mirabal Fariñas

    2014-09-01

    Full Text Available Se efectuó un estudio descriptivo y transversal de 60 pacientes con incontinencia urinaria de esfuerzo, atendidas en la consulta de Urología del Hospital Provincial Docente Clinicoquirúrgico "Saturnino Lora Torres" de Santiago de Cuba, de enero del 2003 a igual mes del 2012, con vistas a evaluar la aplicación de la técnica quirúrgica de suspensión retropúbica en ellas. Entre los resultados relevantes de la serie figuraron: edad promedio de 50 años, incontinencia urinaria de esfuerzo de grados III (48,0 % y II (28,0 % y un elevado porcentaje de continencia posoperatoria inmediata (95,3. A los 3 meses de practicada la intervención, la continencia fue de 92,2 %, mientras que luego de 6 y 9 meses, se obtuvo una continencia de 87,5 %. Se concluyó que la suspensión retropúbica es un procedimiento de elevada efectividad para tratar pacientes con incontinencia urinaria de esfuerzo e incontinencia urinaria mixta, debido a su simple realización y las escasas complicaciones que se producen, lo cual incide favorablemente en la estadía hospitalaria

  13. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  14. Mecanobiología de la interfase hueso-implante dental Mechanobiology of bone-dental implant interphase

    Directory of Open Access Journals (Sweden)

    Juan Carlos Vanegas Acosta

    2010-03-01

    Full Text Available La osteointegración es la conexión estructural y funcional entre el hueso y un implante. Cuando un implante se inserta en el hueso, se crea la denominada interfase hueso-implante, una zona de unión entre la superficie del biomaterial del implante y el hueso circundante. La cicatrización de esta interfase depende de las condiciones biológicas del hueso, las características de diseño del implante y la distribución de cargas entre hueso e implante. En este artículo se hace una revisión del proceso de cicatrización de la interfase hueso-implante para el caso de un implante dental. El objetivo es describir la secuencia de eventos biológicos iniciados con la lesión causada por la inserción del implante y que concluyen con la formación de nuevo hueso en la interfase. Esta descripción incluye una novedosa clasificación de los fenómenos mecánicos que intervienen durante el proceso de cicatrización de los tejidos lesionados. Esta descripción mecanobiológica de la interfase hueso-implante dental se utiliza para determinar las características más relevantes a tener en cuenta en la formulación de un modelo matemático de la osteointegración de implantes dentales.The osteointegration is the structural and functional connection between bone and implant. When an implant is inserted in bone, it creates the so-called bone-implant interphase, a joint zone between implant biomaterial surface and the surrounding bone. The healing of this interphase depends on bone biological conditions, characteristic of implant design and the distribution of loads between bone and implant. The aim of present article is to review of healing process of bone-implant interphase for a dental implant and also to describe the sequence of biological events beginning with lesion caused by implant insertion and leading to the formation of a new bone in the interphase. This description includes a novel classification of mechanical phenomena present in the healing

  15. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    Underlying ion-beam modification of surfaces is the more basic subject of particle-surface interaction. The ideas can be grouped into forward and backward features, i.e. those affecting the interior of the target and those leading to particle expulsion. Forward effects include the stopping of the incident particles and the deposition of energy, both governed by integral equations which are easily set up but difficult to solve. Closely related is recoil implantation where emphasis is placed not on the stopping of the incident particles but on their interaction with target atoms with resulting implantation of these atoms. Backward effects, all of which are denoted as sputtering, are in general either of collisional, thermal, electronic, or exfoliational origin. (Auth.)

  16. Alternativas a la elevación de seno maxilar: implantes cortos Alternatives to maxillary sinus elevation: short implants

    Directory of Open Access Journals (Sweden)

    J. González Lagunas

    2008-12-01

    Full Text Available La mala calidad del hueso, reabsorciones extremas y la presencia de la cavidad del seno maxilar constituían obstáculos insalvables para la rehabilitación implanto-soportada en el sector posterior del maxilar atrófico. La elevación de seno es probablemente la primera opción de tratamiento en el paciente tributario de rehabilitación con implantes en ese sector. El uso de implantes cortos (menos de 10 mm se ha asociado tradicionalmente con unas tasas de supervivencia menores que la de los implantes largos. No obstante la aparición de nuevas superficies y diseños indican que este tipo de implantes puede soportar de forma fiable restauraciones dentales. Presentamos la técnica de instalación de implantes de superficie porosa sinterizada, asi como una revisión actualizada sobre el comportamiento de los implantes cortos.Poor bone quality, extreme bony resorption and a pneumatized mqxillary sinus are a severe Challenger for reconstruction of the atrophic edentuous posterior maxilla. Sinus lift is probably the gold standard for Management of that area. Short implants (<10mm have traditionally been associated with lower survival rates. The introduction of new surfaces and designs indicate that this type of implants can adequately support dental restorations. We present the technique of installation of sinterised porous dental implants together with an update on the behaviour of short implants.

  17. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  18. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  19. ¿Con qué saboreamos?: tareas y experiencias para un taller de ciencias

    Directory of Open Access Journals (Sweden)

    Sánchez Ramos, M.A.

    2008-04-01

    Full Text Available En un grupo de primero de primaria hicimos una pregunta aparentemente simple: ¿Con qué saboreamos? La respuesta inmediata entre los niños fue “con la lengua” y, aunque ésta no fue totalmente correcta, sirvió para iniciar un proyecto en el que se ofreció a los niños la oportunidad para observar, proponer hipótesis, establecerobjetivos y buscar métodos que les ayudaran a resolver la pregunta. Planteamos 4 experiencias cuya finalidad fue que los niños extendieran sus conocimientos y su comprensión sobre un proceso aparentemente sencillo como es la percepción al sabor. Primero cuestionamos la idea de que fuera la lengua el lugar primordial para la detección del sabor (experiencia 1; después incluimos al sentido del olfato como parte de la percepción del sabor (experiencia 2; tratamos de convencer a los niños de que el olor es el elemento más importante para detectar el sabor (experiencia 3; por último discutimos la posibilidad de que fuera el cerebro el que realmente saborea (experiencia 4.

  20. ¿Con qué saboreamos?: tareas y experiencias para un taller de ciencias

    Directory of Open Access Journals (Sweden)

    Marco A. Sánchez Ramos

    2008-01-01

    Full Text Available En un grupo de primero de primaria hicimos una pregunta aparentemente simple: ¿Con qué saboreamos? La respuesta inmediata entre los niños fue "con la lengua" y, aunque ésta no fue totalmente correcta, sirvió para iniciar un proyecto en el que se ofreció a los niños la oportunidad para observar, proponer hipótesis, establecer objetivos y buscar métodos que les ayudaran a resolver la pregunta. Planteamos 4 experiencias cuya finalidad fue que los niños extendieran sus conocimientos y su comprensión sobre un proceso aparentemente sencillo como es la percepción al sabor. Primero cuestionamos la idea de que fuera la lengua el lugar primordial para la detección del sabor (experiencia 1; después incluimos al sentido del olfato como parte de la percepción del sabor (experiencia 2; tratamos de convencer a los niños de que el olor es el elemento más importante para detectar el sabor (experiencia 3; por último discutimos la posibilidad de que fuera el cerebro el que realmente saborea (experiencia 4.

  1. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2013-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  2. Mastopexia con prótesis: técnica triplanar con colgajo en cola de pez para mamas con pobre calidad de cobertura

    Directory of Open Access Journals (Sweden)

    M. Berrocal-Revueltas

    2013-12-01

    Full Text Available La mastopexia con implantes de silicona, es uno de los procedimientos más frecuentes en la práctica diaria en Cirugía Plástica. Sin embargo, la pobre calidad de la cobertura de las mamas, relacionada con piel estriada, escaso tejido subcutáneo y pérdida del parénquima mamario secundarios a la lactancia prolongada y a la pérdida masiva de peso, son causa del incremento progresivo de resultados insatisfactorios a medio y largo plazo que han sido evaluados, analizados y discutidos por los especialistas. Los resultados insatisfactorios más frecuentes en mastopexia con implantes en posición retromuscular son: doble contorno mamario, asimetrías y desplazamiento de los implantes. Los objetivos del presente estudio son: describir el nuevo método triplanar como alternativa útil para lograr mejores resultados en pacientes con mala calidad de cobertura y analizar los resultados obtenidos con el mismo. Realizamos un estudio observacional, descriptivo, prospectivo, en un grupo de 268 pacientes con diagnóstico de ptosis mamaria con hipotrofia y mala calidad de cobertura por piel estriada, escaso tejido celular subcutáneo y pérdida del parénquima mamario, secundarios a lactancia prolongada y pérdida masiva de peso, entre otros, a las que se les practicó mamoplastia de aumento con implantes de silicona mediante la aplicación del método triplanar descrito por la autora, entre enero del 2004 y enero del 2013 en el Hospital de Bocagrande de Cartagena, Colombia. El diseño de la técnica se basa en los principios de cicatriz vertical descrita por Lassus o Lejour o mediante cicatriz en "J", descrita por la autora. El método triplanar se basa en tres planos de cobertura del implante. Plano I: submuscular, para cubrir los dos tercios superiores del implante. Plano II: colgajo dermoglandular con dos prolongaciones distales triangulares de tejido adiposo, en forma de pez, para cubrir el tercio inferior del implante y el borde libre del m

  3. Mecanismos cognitivos en la toma de decisiones en situaciones de incertidumbre. Un estudio con pacientes con demencia tipo Alzheimer

    Directory of Open Access Journals (Sweden)

    Aurora Moreno

    2012-08-01

    Full Text Available Los pacientes con demencia tipo Alzheimer (DTA suelen presentar problemas en la toma de decisiones (TD, incluso ya en fase leve. Diversos estudios han analizado el funcionamiento de los mecanismos cognitivos en los procesos de TD, especialmente en situaciones de incertidumbre. Una de estas aproximaciones es la hipótesis del marcador somático a través de la Iowa Gambling Task (IGT y el índice Gambling (IG. Uno de los problemas es la inespecificidad de los indicadores de la IGT, por ello se han propuesto modelos explicativos para solventar estas carencias, como el Prospective Valence Learning (PVL. En este trabajo, aplicamos la IGT a 10 pacientes y 10 controles. Analizamos los parámetros del PVL: aversión a las pérdidas (λ regla de utilidad (α, recencia (A y consistencia (c, y la evolución de la tarea en función de las elecciones ventajosas. Nuestros resultados muestran que el rendimiento de los controles es mejor que el de pacientes DTA, aunque en las fases iniciales no hay diferencias, estas se ciñen a los dos bloques finales. En los parámetros del PVL se obtienen diferencias en α y c y en menor medida en λ. A partir de los parámetros del PVL podemos caracterizar el proceso de toma de decisiones de los pacientes DTA, como sensibles a las pérdidas, más influenciados por las elecciones inmediatas y un nivel de consistencia muy bajo, que indica estrategias de elección aleatoria.

  4. CORRECCIONES DIFERENCIALES VÍA NTRIP PARA DISPOSITIVO MÓVIL CON APLICACIÓN ANDROID

    Directory of Open Access Journals (Sweden)

    Alfonso Tierra

    Full Text Available El posicionamiento en tiempo real usando GPS se hace mediante correcciones diferenciales enviadas desde una estación base hacia un receptor móvil. Generalmente, la corrección es enviada vía radio o por medio de satélites de comunicación. Con el desarrollo del internet inalámbrica y con el aumento de la cobertura de la señal mediante un Protocolo, conocido como IP, han hecho que se integren estas tecnologías para realizar mediciones para trabajos y estudios en tiempo real usando la tecnología GPS, y mediante el protocolo NTRIP. Esta técnica se ha estado desarrollando e implementando de forma constante en la región, siendo el presente y futuro de las mediciones para trabajos de precisión y en tiempo real. En este trabajo, se muestra la implementación de la técnica NTRIP para posicionamiento en tiempo real. El acceso a datos brutos del GPS en un móvil ANDROID y un navegador Mobile Mapper 10, la utilización de NTRIP para el envió de correcciones diferenciales por medio del protocolo IP, y el internet como red de información inmediata, fueron la base general para crear una aplicación que utiliza una corrección diferencial por posición. Los primeros resultados muestran una mejoría en la posición, pudiendo llegar a obtener un error medio de 2.3m en una Tablet con Android, y 1.6 m con el Mobile Mapper 10; en un tiempo de 5 minutos

  5. Retrograde peri-implantitis

    Directory of Open Access Journals (Sweden)

    Mohamed Jumshad

    2010-01-01

    Full Text Available Retrograde peri-implantitis constitutes an important cause for implant failure. Retrograde peri-implantitis may sometimes prove difficult to identify and hence institution of early treatment may not be possible. This paper presents a report of four cases of (the implant placed developing to retrograde peri-implantitis. Three of these implants were successfully restored to their fully functional state while one was lost due to extensive damage. The paper highlights the importance of recognizing the etiopathogenic mechanisms, preoperative assessment, and a strong postoperative maintenance protocol to avoid retrograde peri-implant inflammation.

  6. Protocolo protésico - quirúrgico en temporización inmediata de dientes unitarios, utilizando una cubeta multifuncional desmontable Prosthetic protocol - surgery in the immediate temporization of a single tooth using a multifunctional removable tray

    OpenAIRE

    Y Leighton; JC Carvajal; A Wolnitzky; R Silva; A Von Marttens

    2010-01-01

    Propósito: El presente reporte clínico es la descripción de un protocolo protésico - quirúrgico que permite la visualización directa del sitio operatorio y el correcto posicionamiento protésico - implantario de una corona temporal atornillada, construida inmediatamente de insertado el implante. Material y métodos: Se seleccionaron 10 pacientes del programa de especialización en implantologia bucomaxilofacial de la Universidad de Chile, cuyo criterio de inclusión principal fue ser desdentado p...

  7. Individual titanium zygomatic implant

    Science.gov (United States)

    Nekhoroshev, M. V.; Ryabov, K. N.; Avdeev, E. V.

    2018-03-01

    Custom individual implants for the reconstruction of craniofacial defects have gained importance due to better qualitative characteristics over their generic counterparts – plates, which should be bent according to patient needs. The Additive Manufacturing of individual implants allows reducing cost and improving quality of implants. In this paper, the authors describe design of zygomatic implant models based on computed tomography (CT) data. The fabrication of the implants will be carried out with 3D printing by selective laser melting machine SLM 280HL.

  8. Reacciones adversas inmediatas a la donación: frecuencia y caracterización, Banco de Sangre de la Clínica Cardiovascular Santa María, Medellín, 1999

    Directory of Open Access Journals (Sweden)

    María I. Múnera

    2001-09-01

    Full Text Available Disponer de un flujo suficiente de donantes altruistas que permita la obtención de componentes sanguíneos de buena calidad es el problema más importante en los bancos de sangre en nuestro medio. La presencia de reacciones adversas a la donación puede influir en forma negativa en la disposición del donante para regresar al banco de sangre. Con el objetivo de establecer la frecuencia y explorar los factores de riesgo involucrados en la aparición de reacciones adversas a la donación, se realizó un estudio de corte, basado en los registros de donantes del Banco de Sangre de la Clínica Cardiovascular Santa María de Medellin durante 1999. La edad promedio de los donantes estudiados fue de 33 años en mujeres y 34 en hombres; se encontró una frecuencia de reacciones adversas de 2,7% y la predominante fue la reacción vasovagal con el 1,2%. Los posibles factores de riesgo relacionados con las reacciones adversas, en general, fueron donación por primera vez, edad menor de 25 años y sexo femenino.

  9. Paciente con esquizofrenia tratado con ziprasidona + clozapina

    Directory of Open Access Journals (Sweden)

    Pol Yanguas E.

    2013-05-01

    Full Text Available P es un paciente diagnosticado de esquizofrenia, sigue en un piso tutelado un programa de rehabilitación, está medicado con clozapina 500 mg/día y ziprasidona 280 mg/ día. Padece hipercolesterolemia, tabaquismo y sus hábitos alimenticios no son buenos. La medicación que utiliza desde 2007 hasta ahora se refleja en la tabla 1. El último tratamiento se le introdujo el 7 de agosto de 2012, habiendo presentado un electro cardiograma (ECG normal, pero con ligera taquicardia ventricular y prolactinemia de 44,8 ng/ml (valores normales: 2-18 ng/ml.

  10. Modelización financiera con Excel

    Directory of Open Access Journals (Sweden)

    Lafuente Robledo, M.

    1998-01-01

    puramente didáctico facilita la comprensión y el estudio del alumno, el cual se tiene que centrar en los aspectos básicos de la asignatura, reduciéndose de forma muy importante la memorización de conceptos. · Permite determinar de manera rápida y exacta los distintos valores que sea necesario obtener y, consecuentemente, comparar entre distintas operaciones financieras planteadas al alumno de forma inmediata. · Operaciones con cálculos numéricos importantes, como la realización de cuadros de amortización de préstamos y empréstitos, también se pueden realizar con gran rapidez, y llevar a cabo un análisis de sensibilidad del mismo. · En general, permite resolver el problema hasta la solución final y extraer las conclusiones operativas, fase que en los cálculos manuales es muchas veces soslayada. Consecuentemente, facilita la detección de posibles inconsistencias y datos erróneos en los planteamientos y resultados. · La utilización de herramientas informáticas ayuda por otra parte a motivar a los alumnos como consecuencia del atractivo generalizado del soporte informático. No obstante, este aspecto no se puede generalizar a todos los alumnos, y además tiene un efecto que se diluye con el tiempo. A continuación, se desarrollan una serie de modelos de matemática financiera con hoja de cálculo con el objeto de ilustrar de forma clara y precisa como se pueden implementar dichos problemas financieros en Excel. Los tres primeros casos corresponden a la matemática financiera clásica y consideramos que deberían representar las aplicaciones informáticas mínimas de cualquier curso de esta disciplina en la Facultades y Escuelas Universitarias de Ciencias Empresariales.

  11. Implant Gigi One-Piece vs Two-Pieces dalam Praktek Sehari-Hari

    Directory of Open Access Journals (Sweden)

    Dian Lestari Kurnia

    2014-12-01

    prosedur bedah dan prosedur prostetik lebih sederhana. Desain ini juga meniadakan celah mikro pada perbatasan implant dan abutment. Desain implant gigi one-piece memiliki keterbatasan pada pilihan prosedur prostetik apabila dibandingkan dengan desain implant gigi two-pieces.   One-Piece Versus Two-pieces Tooth Implant In Daily Practice. Implant had been a gold standard to replace missing tooth. However, implant marketed today was considered complex, and needs a second surgery. Complications may occur such as screw loosening or fracture and the presence of micro gap at implant-abutment-junction that is found causing fixture failure. The one-piece-implant design may offer some advantages. Purpose: this paper was aimed to discuss the pros and cons of one-piece-implants and two-piece-implants. Case 1 A 43-year-old woman came to place an implant on #16. The available bone height was 5 mm. A trans alveolar sinus lift procedure was performed with 0,5 cc allograft. A 12 mm one-piece-implant was inserted. Case 2 A 24-year-old woman came to place an implant on #46. The available bone height was 12 mm and a 10 mm two-piece-implant was inserted. Discussion: One-piece-implant offers some advantage. It needs no second surgery, easier placement protocol, and more natural prosthetic procedures. The design is preventing the failure in implant-abutment-junction failure. The absence of micro gap in one-piece-implant seems superior in preventing crestal bone resorption. However, the prosthetic option was limited in one-piece-implant. Two-piece-implant offers more choices in prosthetic abutment. Conclusion: One-piece-implant was easier and provide simple protocol with limited choice on prosthetic.

  12. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  13. Intercavitary implants dosage calculation

    International Nuclear Information System (INIS)

    Rehder, B.P.

    The use of spacial geometry peculiar to each treatment for the attainment of intercavitary and intersticial implants dosage calculation is presented. The study is made in patients with intercavitary implants by applying a modified Manchester technique [pt

  14. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  15. Determinación del área inmediata afectada por el desagote de la laguna Navarrete, Provincia de Neuquén (36°30'S-71°O)

    OpenAIRE

    I.M. Penna; R.L. Hermanns; A. Folguera

    2007-01-01

    Teniendo en cuenta la alta densidad de avalanchas de roca distribuidas en el norte neuquino y su asociación con cuencas lacustres entre los 36°-38°S y 70°-71°O, son escasos los registros de desagotes catastróficos por colapso de diques naturales, pese a que éste sería el estadio final más probable en su evolución. El presente trabajo está orientado a la delimitación del área inmediatamente afectada por la ruptura del dique natural Navarrete (175 millones de metros cúbicos) generado por la obs...

  16. Uso de la crema Vimang® en la cicatrización alveolar después de la extracción dentaria en un paciente con diabetes mellitus

    OpenAIRE

    Alemán Miranda, Otto; Corona Carpio, Marcia Hortensia; Domínguez Rodríguez, Yamila

    2017-01-01

    Se presenta el caso clínico de un anciano de 75 años de edad, con antecedentes de hipertensión arterial y diabetes mellitus, quien acudió a consulta estomatológica para que le extrajeran el segundo molar inferior izquierdo por presentar gran destrucción debido a caries dental. Después de concluir el proceder se le aplicó la crema Vimang® directamente en el alveolo para acelerar los procesos de cicatrización y evitar cualquier complicación inmediata o mediata; luego se indicó 4 veces al día de...

  17. Videojuego con Realidad Virtual

    OpenAIRE

    González Mora, César

    2017-01-01

    El objetivo del proyecto es el desarrollo de un videojuego deportivo que utilice realidad mixta. El videojuego se podrá utilizar con dispositivos de tipo cardboard, y utilizará realidad aumentada para la interacción del jugador con el videojuego. En el desarrollo se utilizará el motor Unity para conseguir una aplicación multiplataforma, y la librería Vuforia para implementar realidad mixta.

  18. Sistemas integrados con Arduino

    OpenAIRE

    EL YAKOUTI, MOHAMMED

    2017-01-01

    Design of a robot prototype remotely controllable from Bluetooth using Arduino. Control and testing of sensors and events interacting with Arduino and Bluetooth. Diseño de un prototipo de robot controlable remotamente con Bluetooth utilizando Arduino. Control y verificación de los sensores y eventos que interactúan mediante el Arduino y el Bluetooth. El Yakouti, M. (2017). Sistemas integrados con Arduino. http://hdl.handle.net/10251/89274. TFGM

  19. Rehabilitación sobre implantes oseointegrados A case with rehabilitation on boneintegrated implants

    Directory of Open Access Journals (Sweden)

    Leticia María Lemus Cruz

    2009-03-01

    Full Text Available Se presenta un caso de un paciente rehabilitado en la consulta de Implantología de la Facultad de Estomatología de Ciudad de La Habana. La historia de la implantología moderna se remonta a principios de los años 60, cuando Per-Ingvar Branemark sienta las bases de la osteointegración y describe los primeros implantes de titanio con forma de tornillo. Aunque antigua, es la prótesis más moderna. Si la meticulosidad es obligada en la elaboración de todo tipo de prótesis, en los trabajos de implantes no se admite el más mínimo fallo, desde la planificación del caso hasta la implantación de la prótesis en boca. Para obtener buenos resultados, las técnicas y los procesos han de observarse escrupulosamente. En nuestra Facultad se ha creado el Grupo de Implantología, que es el encargado de la colocación de implantes y la rehabilitación prótesica de estos. Para ello han sido utilizado diferentes tipos de implantes comercializados y patentizados al nivel mundial. Se reafirma que la rehabilitación sobre implantes mejora la calidad estética y funcional de los pacientes.A case of rehabilitation patient is presented seen in Implantation Science consulting room of Stomatology Faculty of Havana City. History of implantation science dates back to at the beginning of 60s, when Per-Ingvar Branemark creates the bases of bone-integration and to describe the firsts titanium implants in a screw form. Although ancient, it is the more modern prosthesis. If meticulousness if mandatory in elaboration of all type of prosthesis, in implants works it inadmissible the minimum of failure, from the case planning until prosthesis implantation in mouth. To achieve good results, techniques and processes has to be scrupulously observed. In our Faculty it has been created a group of Implantation Science, which is in charge of implants placement, and of the prosthetic rehabilitation of these. Thus, we used different types of marketed and showed at world level. It

  20. Los implantes MG-OSSEOUS: Estudio multicéntrico retrospectivo MG-OSSEOUS implants: A multicentric retrospective study

    Directory of Open Access Journals (Sweden)

    E. Serrano Caturla

    2006-12-01

    Full Text Available Objetivo. Aportar unos datos estadísticamente fiables sobre la supervivencia e incidencias asociadas a los implantes y prótesis del modelo MG-OSSEOUS (Mozo-Grau, S.L., Valladolid, España y demostrar que su eficacia es comparable a todas las marcas comerciales. Material y método. Estudio multicéntrico retrospectivo coordinado por la empresa Scientific Management in O&SS (Barcelona, España. Se colocaron 1001 implantes en 247 pacientes y se diseñaron 328 prótesis, entre los años 2004 y 2005, con un seguimiento de 2 años. Todos los implantes cargados. Se analizan y pormenorizan todos los implantes, por diámetros, longitudes, posiciones, fases quirúrgicas, cargas, tipos y modelos de prótesis y técnicas complementarias aplicadas, tanto sincrónica como anacrónicamente. Resultados. Tras la homogeneización de las muestras, se objetiva una supervivencia del 97,8% a los 2 años, detallando los fracasos según las características de cada caso clínico. No se reporta ningún fracaso de la prótesis. Discusión. Protocolizamos una serie de criterios e indicaciones a la hora de colocar los implantes MG-OSSEOUS según los casos clínicos. Comparamos nuestros resultados con la bibliografía, tanto pretérita como actual, coincidiendo con la manera de actuar a lo largo de la historia de la implantología. Finalmente, extrapolamos los resultados que consideramos comparables a los publicados por el grupo Branemark. Conclusión. La calidad del implante MG-OSSEOUS combinada con protocolos implantológicos científicamente contrastados, muestra un 2,2% de fracaso a los 2 años de seguimiento, con un porcentaje de éxito del 100% tanto en la recolocación del implante como en la fase protésica.Objective. We present some statistically contrasted results regarding the survival and incidences of MG-OSSEOUS implants and prosthetic components (Mozo-Grau, S.L., Valladolid, Spain, and we prove that they have the same efficacy when compared with other

  1. Investigando con personas con dificultades de aprendizaje

    Directory of Open Access Journals (Sweden)

    Borja González Luna

    2013-12-01

    Full Text Available El artículo muestra los orígenes de lo que Walmsley (2008 denomina «investigación inclusiva». Para comprender qué se entiende por investigación inclusiva tenemos que remontarnos a los debates epistemológicos sobre las metodologías cuantitativas y cualitativas, acontecidos en la década de los 90, en torno a la revista Disability & Society. A partir de una síntesis de dichos debates, focalizados en el ámbito de la «discapacidad intelectual y del desarrollo», se exponen dos estrategias de colaboración con dicha población: a una aproximación etnográfica (de trabajo grupal, y b una aproximación biográfica (de trabajo individual. A continuación se esboza un posible diseño de trabajo de campo que intenta superar el paradigma cualitativo «clásico» con el objetivo de incluir a dicho colectivo más allá del rol de «sujetos de la investigación». Para finalizar se recoge el debate sobre la accesibilidad de los resultados de la investigación a los participantes en dichas investigaciones, y con ello la necesaria innovación en el ámbito de las «devoluciones» de los resultados, cuando se trata de incluir a personas que presentan limitaciones para la comprensión del lenguaje abstracto oral y/o escrito.

  2. Trends in cochlear implants.

    Science.gov (United States)

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.

  3. Benefits and Risks of Cochlear Implants

    Science.gov (United States)

    ... and Medical Procedures Implants and Prosthetics Cochlear Implants Benefits and Risks of Cochlear Implants Share Tweet Linkedin ... the Use of Cochlear Implants What are the Benefits of Cochlear Implants? For people with implants: Hearing ...

  4. Bloqueio extraconal para facectomia com implante de lente intra-ocular: influência do fentanil associado ao anestésico local na qualidade do bloqueio e na analgesia pós-operatória Bloqueo extraconal para facectomia con implantación de lente intra-ocular: influencia del fentanil asociado al anestésico local en la calidad del bloqueo y en la analgesia pos-operatoria Extraconal block for cataract extraction surgery with implantation of intraocular lens: contribution of fentanyl associated to local anesthetics for quality of block and postoperative analgesia

    Directory of Open Access Journals (Sweden)

    Daniel Espada Lahoz

    2003-09-01

    de analgésicos con fentanil - 20,7%, en el uso de analgésicos con fentanil - 41,5%. CONCLUSIONES: En las condiciones de este estudio el fentanil mejoró la calidad del bloqueo cuanto a la motilidad del músculo recto medial y diminuyó la necesidad de analgésicos en el pos-operatorio.BACKGROUND AND OBJECTIVES: Loco-regional anesthesia for cataract extraction surgery offers as advantages minimum physiological changes, complete anesthesia, eye reflexes blockade, lower incidence of nausea and vomiting and shorter recovery time, in addition to postoperative analgesia. Continuous concern with blockade quality as well as with postoperative analgesia is responsibility of the anesthesiologist. This study aimed at evaluating whether fentanyl has contributed to blockade quality and postoperative analgesia in cataract extraction surgery with implantation of intraocular lens. METHODS: The association of fentanyl and 0.75% bupivacaine for eye blockade and postoperative analgesia was evaluated in 164 patients undergoing cataract extraction with implantation of intraocular lens (extracapsular technique. Patients were homogeneous in gender, demographics, operated eye, ASA physical status and Goldman’s cardiac risk index. Patients were randomly allocated in two groups (82 patients each: with or without fentanyl. Blockade quality was evaluated according to the following parameters: intraoperative pain; eyelid and/or eyeball movement; Bell’s reflex persistence; number of blocks needed to produce akinesia and surgeons evaluation of blockade. Postoperative analgesia was evaluated by patients’ request for additional postoperative analgesia. RESULTS: Results have shown that fentanyl has significantly improved medial rectus muscle blockade quality (with fentanyl - 17.1%; without fentanyl - 32.9% and has decreased postoperative analgesics consumption (analgesics with fentanyl - 20.7%; no analgesics with fentanyl - 41.5%. CONCLUSIONS: In the conditions of this study, fentanyl has

  5. Bifosfonatos e implantes dentales, ¿son incompatibles? Revisión de la literatura

    Directory of Open Access Journals (Sweden)

    Manuel Moreno-Sánchez

    2016-07-01

    Conclusiones: El tratamiento con bifosfonatos no disminuye la osteointegración del implante dental, aunque estos resultados se han obtenido en base a estudios retrospectivos en humanos. Se han descrito casos de osteonecrosis de los maxilares relacionada con bifosfonatos en estos pacientes, sobre todo tras tratamiento prolongado.

  6. Giochiamo con i robot

    Directory of Open Access Journals (Sweden)

    Andrea Bonarini

    2009-01-01

    Full Text Available "Giochiamo con i robot" e' un laboratorio interattivo per grandi e piccini realizzato per l'edizione 2007 del Festival della Scienza di Genova. Lungo un percorso che va dalla telerobotica alla robotica evolutiva, il laboratorio sviluppa il tema di dare intelligenza ai robot. Questo percorso, le cui tappe sono le varie installazioni, si conclude nella "bottega" dove e' possibile costruire e programmare i propri robot o smontare e modificare quelli esposti durante il percorso didattico. I visitatori sono coinvolti in attivita' ludiche grazie alle quali possonoentrare in contatto con alcune delle idee potenti della robotica,

  7. disegnare con ... Alberto Pratelli

    Directory of Open Access Journals (Sweden)

    Roberto Mingucci

    2017-12-01

    Full Text Available Con questa breve intervista ad Alberto Pratelli, (non a caso scelto per aprire questa nuova rubrica intendia-mo inaugurare un dialogo con personalità significati-ve del Disegno di Architettura, che consenta riflessioni dedicate alle sue varie dimensioni, oggi più che mai da approfondire. La suggestione a farlo, viene da un’idea di Pablo Rodri-guez Navarro ed abbiamo quindi pensato di avviarla proprio in questo numero, che Pablo ha accettato di curare su un tema a lui particolarmente caro.

  8. Optical effects of ion implantation

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1987-01-01

    The review concerns the effects of ion implantation that specifically relate to the optical properties of insulators. Topics which are reviewed include: ion implantation, ion range and damage distributions, colour centre production by ion implantation, high dose ion implantation, and applications for integrated optics. Numerous examples are presented of both diagnostic and industrial examples of ion implantation effects in insulators. (U.K.)

  9. Perfil cognitivo en pacientes con infección por el virus de inmunodeficiencia humana neurológicamente asintomáticos

    Directory of Open Access Journals (Sweden)

    Erik Guevara-Silva

    2013-01-01

    Full Text Available Introducción: Diversos estudios han comunicado la presencia de deterioro cognitivo asociado al virus de inmunodeficiencia humana (VIH tipo 1, aún en estadios tempranos de la infección. Las principales funciones comprometidas son la memoria a corto plazo, velocidad psicomotriz, atención y función ejecutiva. Objetivos: Describir el perfil cognitivo en pacientes con VIH neurológicamente asintomáticos, antes de iniciar terapia antirretroviral de gran actividad (TARGA, y determinar posibles factores asociados. Diseño: Estudio transversal-analítico. Lugar: Hospital Regional de Huacho. Participantes: Pacientes con VIH y con criterios para ingresar a TARGA. Intervenciones: Veintiún pacientes con VIH, que fueron atendidos desde de abril a julio de 2011, fueron evaluados clínicamente y se les administró una batería neuropsicológica estandarizada. Principales medidas de resultados: Puntajes alcanzados en las pruebas de velocidad psicomotriz, función ejecutiva, memoria inmediata, atención y habilidades visuoespaciales. Resultados: El 47,6% de pacientes presentó un deterioro cognitivo significativo. Los pacientes fallaron principalmente en las pruebas de velocidad psicomotriz y función ejecutiva. Con excepción de un paciente, todos fracasaron en al menos un test. La edad, tiempo de enfermedad, grado de instrucción y depresión no influyeron significativamente sobre el perfil cognitivo. Conclusiones: Estos hallazgos sugieren que el compromiso cognitivo en algún grado puede presentarse desde las fases tempranas y asintomáticas de la infección por el VIH; estos hallazgos coinciden con la literatura.

  10. Ion implantation in semiconductors

    International Nuclear Information System (INIS)

    Gusev, V.; Gusevova, M.

    1980-01-01

    The historical development is described of the method of ion implantation, the physical research of the method, its technological solution and practical uses. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material, ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions. (M.S.)

  11. Ion implantation in semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Gusev, V; Gusevova, M

    1980-06-01

    The historical development of the method of ion implantation, the physical research of the method, its technological solution and practical uses is described. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material and ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions.

  12. Trends in Cochlear Implants

    OpenAIRE

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic as...

  13. 74. Reparación Con Neocuerdas en Distintos Tipos de Prolapso Mitral

    OpenAIRE

    R. García Fuster; A. García; E. Martín; F. Paredes; R. Payá; J. Fontana

    2012-01-01

    la resección cuadrangular es referente en la reparación del prolapso de velo posterior. El velo anterior plantea más limitaciones, siendo la transposición de cuerdas y el implante de neocuerdas los procedimientos más empleados. Analizamos eficacia y versatilidad de la reparación con neocuerdas en cinco variantes de prolapso mitral (vídeo). Material y métodos: han sido intervenidos 5 pacientes con distintos tipos de prolapso. Tres con deficiencia fibroelástica: varón de 52 años con prolapso...

  14. Ion implantation technology

    CERN Document Server

    Downey, DF; Jones, KS; Ryding, G

    1993-01-01

    Ion implantation technology has made a major contribution to the dramatic advances in integrated circuit technology since the early 1970's. The ever-present need for accurate models in ion implanted species will become absolutely vital in the future due to shrinking feature sizes. Successful wide application of ion implantation, as well as exploitation of newly identified opportunities, will require the development of comprehensive implant models. The 141 papers (including 24 invited papers) in this volume address the most recent developments in this field. New structures and possible approach

  15. High energy ion implantation

    International Nuclear Information System (INIS)

    Ziegler, J.F.

    1985-01-01

    High energy ion implantation offers the oppertunity for unique structures in semiconductor processing. The unusual physical properties of such implantations are discussed as well as the special problems in masking and damage annealing. A review is made of proposed circuit structures which involve deep implantation. Examples are: deep buried bipolar collectors fabricated without epitaxy, barrier layers to reduce FET memory sensitivity to soft-fails, CMOS isolation well structures, MeV implantation for customization and correction of completed circuits, and graded reach-throughs to deep active device components. (orig.)

  16. [Silastic implant and synovitis].

    Science.gov (United States)

    Sennwald, G

    1989-07-22

    The silastic implant based on siloxane polymere induces granulomatous synovitis in certain predisposed individuals, a reaction which may continue even after removal of the implant. This is also true of a prosthesis of the trapezium in two of our patients, though to a lesser degree. This is probably the reason why the problem has not yet been widely recognized. The hypothesis is put forward that an enzymatic predisposition may allow chemical degradation of the fragmented silastic implant into a toxic component responsible for the pathologic condition. The slow progression of the lesions is a challenge for the future and puts in question the further use of silastic implants.

  17. Cochlear implant magnet retrofit.

    Science.gov (United States)

    Cohen, N L; Breda, S D; Hoffman, R A

    1988-06-01

    An implantable magnet is now available for patients who have received the standard Nucleus 22-channel cochlear implant and who are not able to wear the headband satisfactorily. This magnet is attached in piggy-back fashion to the previously implanted receiver/stimulator by means of a brief operation under local anesthesia. Two patients have received this magnet retrofit, and are now wearing the headset with greater comfort and satisfaction. It is felt that the availability of this magnet will increase patient compliance in regard to hours of implant usage.

  18. Conversando con Oriol Bohigas

    OpenAIRE

    Redondo Domínguez, Ernesto; Moya Sala, Joaquim

    2015-01-01

    [EN] Interview with Oriol Bohigas [ES] Entrevista con Oriol Bohigas Redondo Domínguez, E.; Moya Sala, J. (2015). Conversando con… Oriol Bohigas. EGA. Revista de Expresión Gráfica Arquitectónica. 20(26):22-35. doi:10.4995/ega.2015.4061 22 35 20 26

  19. DR Con o:

    African Journals Online (AJOL)

    which could fall under the Ugandan influence. The con-. flict in the ..... The Congolese people and international community within SADC, the AU ..... ments and make peace among themselves. However, one ... friends overnight.There is a great ...

  20. fertilizada con diferentes abonos

    Directory of Open Access Journals (Sweden)

    Jorge Alberto Elizondo-Salazar

    2007-01-01

    Full Text Available Producción y calidad de la biomasa de morera (Morus alba fertilizada con diferentes abonos. Se llevó a cabo un experimento en la Estación Experimental “Alfredo Volio Mata” de la Universidad de Costa Rica con el fi n de evaluar la aplicación de 150 kg de N/ha/año proveniente de dos abonos orgánicos: lombriabono y compostaje; y de un fertilizante químico, sobre la producción y calidad de la biomasa de morera. El periodo experimental comprendió un ciclo de 12 meses, iniciando en julio del 2003 y fi nalizando en julio del 2004. Se utilizó una plantación de morera de 12 años de establecida con una densidad de siembra de 27.777 plantas/ ha. Se empleó un diseño de bloques completos al azar con cuatro tratamientos: dos abonos orgánicos, nitrato de amonio (33,5% N y un control. Las plantas se podaron a 0,6 m sobre el nivel del suelo al inicio del ensayo. Durante el periodo experimental, las plantas fueron podadas consecutivamente cada 90 días. Las hojas y los tallos fueron separados y analizados para determinar el contenido de materia seca y proteína cruda. La producción de materia seca fue 23% superior y el contenido de proteína cruda fue signifi cativamente mayor con el nitrógeno químico, mientras que el contenido de materia seca fue menor. No se encontraron diferencias signifi cativas entre el tratamiento control y los tratamientos orgánicos.

  1. Percutaneous and skeletal biocarbon implants

    Science.gov (United States)

    Mooney, V.

    1977-01-01

    Review of carbon implants developed by NASA discussed four different types of implants and subsequent improvements. Improvements could be of specific interest to rehabilitation centers and similar organizations.

  2. Degradable Implantate: Entwicklungsbeispiele

    Science.gov (United States)

    Ruffieux, Kurt; Wintermantel, Erich

    Resorbierbare Implantate werden seit mehreren Jahrzehnten in der Implantologie eingesetzt. Bekannt wurden diese Biomaterialien mit dem Aufkommen von sich selbst auflösenden Nahtfäden auf der Basis von synthetisch hergestellten Polylactiden und Polyglycoliden in den 70er Jahren. In einem nächsten Schritt wurden Implantate wie Platten und Schrauben zur Gewebefixation aus den gleichen Biomaterialien hergestellt.

  3. Risks of Breast Implants

    Science.gov (United States)

    ... have a risk of developing a type of cancer called breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) in the breast tissue surrounding the implant. BIA-ALCL is not breast cancer. Women diagnosed with BIA-ALCL may need to ...

  4. Ion implantation of metals

    International Nuclear Information System (INIS)

    Dearnaley, G.

    1976-01-01

    In this part of the paper descriptions are given of the effects of ion implantation on (a) friction and wear in metals; and (b) corrosion of metals. In the study of corrosion, ion implantation can be used either to introduce a constituent that is known to convey corrosion resistance, or more generally to examine the parameters which control corrosion. (U.K.)

  5. Ion implantation into diamond

    International Nuclear Information System (INIS)

    Sato, Susumu

    1994-01-01

    The graphitization and the change to amorphous state of diamond surface layer by ion implantation and its characteristics are reported. In the diamond surface, into which more than 10 16 ions/cm 2 was implanted, the diamond crystals are broken, and the structure changes to other carbon structure such as amorphous state or graphite. Accompanying this change of structure, the electric conductivity of the implanted layer shows two discontinuous values due to high resistance and low resistance. This control of structure can be done by the temperature of the base during the ion implantation into diamond. Also it is referred to that by the base temperature during implantation, the mutual change of the structure between amorphous state and graphite can be controlled. The change of the electric resistance and the optical characteristics by the ion implantation into diamond surface, the structural analysis by Raman spectroscopy, and the control of the structure of the implanted layer by the base temperature during implantation are reported. (K.I.)

  6. Number of implants for mandibular implant overdentures: a systematic review

    Science.gov (United States)

    Lee, Jeong-Yol; Kim, Ha-Young; Bryant, S. Ross

    2012-01-01

    PURPOSE The aim of this systematic review is to address treatment outcomes of Mandibular implant overdentures relative to implant survival rate, maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted by a PubMed search strategy and hand-searching of relevant journals from included studies. Randomized Clinical Trials (RCT) and comparative clinical trial studies on mandibular implant overdentures until August, 2010 were selected. Eleven studies from 1098 studies were finally selected and data were analyzed relative to number of implants. RESULTS Six studies presented the data of the implant survival rate which ranged from 95% to 100% for 2 and 4 implant group and from 81.8% to 96.1% for 1 and 2 implant group. One study, which statistically compared implant survival rate showed no significant differences relative to the number of implants. The most common type of prosthetic maintenance and complications were replacement or reattaching of loose clips for 2 and 4 implant group, and denture repair due to the fracture around an implant for 1 and 2 implant groups. Most studies showed no significant differences in the rate of prosthetic maintenance and complication, and patient satisfaction regardless the number of implants. CONCLUSION The implant survival rate of mandibular overdentures is high regardless of the number of implants. Denture maintenance is likely not inflenced substantially by the number of implants and patient satisfaction is typically high again regardless os the number of implants. PMID:23236572

  7. Ion implantation into iron

    International Nuclear Information System (INIS)

    Iwaki, Masaya

    1978-01-01

    The distribution of implanted ions in iron, the friction characteristics and the corrosion of iron were studied. The distribution of Ni or Cr ions implanted into mild steel was measured. The accelerated voltage was 150 keV, and the beam current density was about 2 microampere/cm 2 . The measurement was made with an ion microanalyzer. The measured distribution was compared with that of LSS theory. Deep invasion of Ni was seen in the measured distribution. The distribution of Cr ions was different from the distribution calculated by the LSS theory. The relative friction coefficient of mild steel varied according to the dose of implanted Cu or N ions, and to the accelerating voltage. Formation of compound metals on the surfaces of metals by ion-implantation was investigated for the purpose to prevent the corrosion of metals. The resistance of mild steel in which Ni ions were implanted was larger than that of mild steel without any treatment. (Kato, T.)

  8. pacientes con falla cardiaca

    Directory of Open Access Journals (Sweden)

    Diana Marcela Achury Saldaña

    2007-01-01

    Full Text Available Objetivo: determinar la adherencia al tratamiento de pacientes con falla cardiaca hospitalizados, al aplicar un plan educativo quefomenta el autocuidado.Método: estudio cuasiexperimental (entrevistas enfermera-paciente realizado entre diciembre de 2004 y mayo de 2006, con unamuestra de 50 pacientes seleccionados por conveniencia. Se diseñó un instrumento para evaluar los comportamientos de los pacientes,con base en algunos resultados de la adherencia y sus respectivos indicadores de la taxonomía NOC (Nursing out comes classification. Laadherencia al tratamiento fue medida en dos momentos: el primero durante la hospitalización, seguido de la aplicación del plan educativoantes del alta, que proporcionaba información en el manejo de su enfermedad desde una dimensión física, psicológica y social quepromueve el autocuidado; y el segundo un mes después del alta en su domicilio.Resultados: diferencias estadísticamente significativas (P=0,0001 que demuestran cómo mediante la capacitación al paciente enel manejo de su tratamiento farmacológico y no farmacológico, el establecimiento de una sana relación entre el profesional de enfermeríay el paciente, y la participación de la familia, se logra una total adherencia al tratamiento.Conclusiones: para lograr una adherencia total del paciente con falla cardiaca al tratamiento es necesario un proceso educativo y unseguimiento continuo y personalizado que motive permanentemente al paciente y se le reconozca el papel protagónico en su cuidado y manejo de la enfermedad.

  9. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  10. Implants for orthodontic anchorage

    Science.gov (United States)

    Zheng, Xiaowen; Sun, Yannan; Zhang, Yimei; Cai, Ting; Sun, Feng; Lin, Jiuxiang

    2018-01-01

    Abstract Implantanchorage continues to receive much attention as an important orthodontic anchorage. Since the development of orthodontic implants, the scope of applications has continued to increase. Although multiple reviews detailing implants have been published, no comprehensive evaluations have been performed. Thus, the purpose of this study was to comprehensively evaluate the effects of implants based on data published in review articles. An electronic search of the Cochrane Library, Medline, Embase, Ebsco and Sicencedirect for reviews with “orthodontic” and “systematic review or meta analysis” in the title, abstract, keywords, or full text was performed. A subsequent manual search was then performed to identify reviews concerning orthodontic implants. A manual search of the orthodontic journals American Journal of Orthodontics and Dentofacial Orthopedics (AJODO), European Journal of Orthodontics (EJO), and Angle Othodontist was also performed. Such systematic reviews that evaluated the efficacy and safety of orthodontic implants were used to indicate success rates and molar movements. A total of 23 reviews were included in the analysis. The quality of each review was assessed using a measurement tool for Assessment of Multiple Systematic Reviews (AMSTAR), and the review chosen to summarize outcomes had a quality score of >6. Most reviews were less than moderate quality. Success rates of implants ranged in a broad scope, and movement of the maxillary first molar was superior with implants compared with traditional anchorage. PMID:29595673

  11. Maintenance in dental implants

    Directory of Open Access Journals (Sweden)

    Giselle Póvoa Gomes

    2008-01-01

    Full Text Available In implants, maintenance is a decisive factor for obtaining success when implant supported overdentures and dentures are used. The present stud presents, a clinical case of a patient, a 70 year-old white man, with a completely edentulous mandibular alveolar ridge, severe bone resorption with presence of basal bone only, and absence of vestibule. Initially, treatment consisted of the placement of a mandibular overdenture, supported on three implants in the anterior inter-foramen region, as the left implant was transfixed in the basal bone of 2 to 3 millimeters. Eleven years later, another two implants were placed in the anterior area and an immediate load was performed up to the first molars, for the placement of an implant supported fixed. Throughout the entire treatment, meticulous maintenance was carried out, with follow-up for fourteen years, interrupted by the patient’s death. From the third month after the opening the three implants initially placed, the presence of keratinized mucosa, definition of the vestibule, maturation of the alveolar ridge and bone formation in the mento region were observed. It was concluded that good planning, allied to mastery of the technique and adequate maintenance were the prerequisites necessary for obtaining favorable results, success of the present case, and for the patient to have a better quality of life.

  12. Nanotechnology for dental implants.

    Science.gov (United States)

    Tomsia, Antoni P; Lee, Janice S; Wegst, Ulrike G K; Saiz, Eduardo

    2013-01-01

    With the advent of nanotechnology, an opportunity exists for the engineering of new dental implant materials. Metallic dental implants have been successfully used for decades, but they have shortcomings related to osseointegration and mechanical properties that do not match those of bone. Absent the development of an entirely new class of materials, faster osseointegration of currently available dental implants can be accomplished by various surface modifications. To date, there is no consensus regarding the preferred method(s) of implant surface modification, and further development will be required before the ideal implant surface can be created, let alone become available for clinical use. Current approaches can generally be categorized into three areas: ceramic coatings, surface functionalization, and patterning on the micro- to nanoscale. The distinctions among these are imprecise, as some or all of these approaches can be combined to improve in vivo implant performance. These surface improvements have resulted in durable implants with a high percentage of success and long-term function. Nanotechnology has provided another set of opportunities for the manipulation of implant surfaces in its capacity to mimic the surface topography formed by extracellular matrix components of natural tissue. The possibilities introduced by nanotechnology now permit the tailoring of implant chemistry and structure with an unprecedented degree of control. For the first time, tools are available that can be used to manipulate the physicochemical environment and monitor key cellular events at the molecular level. These new tools and capabilities will result in faster bone formation, reduced healing time, and rapid recovery to function.

  13. Cementos con cenizas volantes

    Directory of Open Access Journals (Sweden)

    Ossa M., Mauricio

    1984-03-01

    additions of 20 and 30% .

    Casi la generalidad de los estudios realizados sobre cementos con adición de cenizas volantes se refieren a sus características y comportamiento en pastas, morteros y hormigones, siempre en relación con aquéllos del cemento portland. Esta vez, se desarrolló un trabajo experimental orientado a relacionar entre sí los cementos con adiciones de cenizas volantes y de puzolana natural. Para ello se fabricaron a escala de laboratorio cementos de ambos tipos, empleando como materias primas comunes clinker y yeso y, como variables, diferentes porcentajes de las dos adiciones, que cumplieron previamente los requisitos normalizados en cuanto a sus actividades puzolánicas. La calidad de los cementos fabricados resultó adecuada y concordante con la del cemento portland-puzolánico obtenido a escala industrial con los mismos clinker, yeso y puzolana natural de este estudio. Posteriormente, se determinaron las características de los cementos experimentales y se confeccionaron morteros normales para la realización de ensayos físicos y mecánicos. Los resultados de ensayos indicaron que los cementos con adición de cenizas volantes (CCV requieren menos agua para consistencia normal, presentan tiempos de fraguado mayores y expansiones en autoclave menores que los cementos con adición de puzolana (CP. Los calores de hidratación a 7 y 28 días de edad fueron aproximadamente similares para ambos tipos de cemento. En morteros normales, los cementos CCV mostraron menor retracción de secado, mayor retentividad y mayor fluidez (para igual cantidad de agua que los cementos CP. En los ensayos de exudación se observó que ésta depende más de la finura que el tipo de adición. Finalmente, los ensayos mecánicos señalaron que las resistencias a compresión y flexotracción de los morteros con cementos CCV son menores a edades inferiores que 14 días (del orden de 5 a 10% a un día de edad, pero que a partir de entonces pasan a ser mayores que las de

  14. Ion implantation for microelectronics

    International Nuclear Information System (INIS)

    Dearnaley, G.

    1977-01-01

    Ion implantation has proved to be a versatile and efficient means of producing microelectronic devices. This review summarizes the relevant physics and technology and assesses the advantages of the method. Examples are then given of widely different device structures which have been made by ion implantation. While most of the industrial application has been in silicon, good progress continues to be made in the more difficult field of compound semiconductors. Equipment designed for the industrial ion implantation of microelectronic devices is discussed briefly. (Auth.)

  15. Optimization of dental implantation

    Science.gov (United States)

    Dol, Aleksandr V.; Ivanov, Dmitriy V.

    2017-02-01

    Modern dentistry can not exist without dental implantation. This work is devoted to study of the "bone-implant" system and to optimization of dental prostheses installation. Modern non-invasive methods such as MRI an 3D-scanning as well as numerical calculations and 3D-prototyping allow to optimize all of stages of dental prosthetics. An integrated approach to the planning of implant surgery can significantly reduce the risk of complications in the first few days after treatment, and throughout the period of operation of the prosthesis.

  16. competencia con China

    Directory of Open Access Journals (Sweden)

    Elena de la Paz Hernández Águila

    2007-01-01

    Full Text Available El artículo ofrece un diagnóstico del desempeño de la industria mexicana del calzado desde la década de los ochenta hasta la actualidad. Analiza la problemática que ha enfrentado esta rama industrial a partir del proceso de apertura comercial y de la competencia en su mercado interno con productos provenientes de países asiáticos, particularmente China. Problematiza al respecto los retos y las perspectivas que a mediano plazo enfrentará este sector empresarial y sobre las posibilidades de competir en el mercado globalizado.

  17. Construir con Madera

    OpenAIRE

    Olabe-Velasco, F. (Fermín); Val-Hernández, Y. (Yolanda); Varela-de-la-Cruz, P. (Perla); Cabrero-Ballarín, J.M. (José Manuel)

    2010-01-01

    Guía divulgativa ‘Construir con madera’, elaborada por la Cátedra Madera de la Universidad de Navarra y el Gobierno de Navarra. La publicación pretende explicar de forma sencilla los beneficios y posibilidades de este material en la construcción, tanto en lo que respecta a su resistencia, comportamiento frente al fuego, durabilidad, capacidad de aislamiento, propiedades acústicas, estética, respeto al medio ambiente y sostenibilidad como fuente de energía. A modo de ejemplo, en la ...

  18. Breast Reconstruction with Implants

    Science.gov (United States)

    ... your surgical options and discuss the advantages and disadvantages of implant-based reconstruction, and may show you ... Policy Notice of Privacy Practices Notice of Nondiscrimination Advertising Mayo Clinic is a not-for-profit organization ...

  19. Ion Implantation of Polymers

    DEFF Research Database (Denmark)

    Popok, Vladimir

    2012-01-01

    The current paper presents a state-of-the-art review in the field of ion implantation of polymers. Numerous published studies of polymers modified by ion beams are analysed. General aspects of ion stopping, latent track formation and changes of structure and composition of organic materials...... are discussed. Related to that, the effects of radiothermolysis, degassing and carbonisation are considered. Specificity of depth distributions of implanted into polymers impurities is analysed and the case of high-fluence implantation is emphasised. Within rather broad topic of ion bombardment, the focus...... is put on the low-energy implantation of metal ions causing the nucleation and growth of nanoparticles in the shallow polymer layers. Electrical, optical and magnetic properties of metal/polymer composites are under the discussion and the approaches towards practical applications are overviewed....

  20. Precipitation processes in implanted materials

    International Nuclear Information System (INIS)

    Borders, J.A.

    1978-01-01

    Ion implantation is a nonequilibrium process. It is possible to implant materials with impurities to concentration levels which exceed the solid solubilities. The return of the system to thermodynamic equilibrium is often accomplished by precipitation of the implanted species or a compound involving atoms of both the host and the implanted species. This may involve long time scales when taking place at room temperature or it may take place during the implantation

  1. Ion implantation for semiconductors

    International Nuclear Information System (INIS)

    Grey-Morgan, T.

    1995-01-01

    Full text: Over the past two decades, thousands of particle accelerators have been used to implant foreign atoms like boron, phosphorus and arsenic into silicon crystal wafers to produce special embedded layers for manufacturing semiconductor devices. Depending on the device required, the atomic species, the depth of implant and doping levels are the main parameters for the implantation process; the selection and parameter control is totally automated. The depth of the implant, usually less than 1 micron, is determined by the ion energy, which can be varied between 2 and 600 keV. The ion beam is extracted from a Freeman or Bernas type ion source and accelerated to 60 keV before mass analysis. For higher beam energies postacceleration is applied up to 200 keV and even higher energies can be achieved by mass selecting multiplycharged ions, but with a corresponding reduction in beam output. Depending on the device to be manufactured, doping levels can range from 10 10 to 10 15 atoms/cm 2 and are controlled by implanter beam currents in the range up to 30mA; continuous process monitoring ensures uniformity across the wafer of better than 1 % . As semiconductor devices get smaller, additional sophistication is required in the design of the implanter. The silicon wafers charge electrically during implantation and this charge must be dissipated continuously to reduce the electrical stress in the device and avoid destructive electrical breakdown. Electron flood guns produce low energy electrons (below 10 electronvolts) to neutralize positive charge buildup and implanter design must ensure minimum contamination by other isotopic species and ensure low internal sputter rates. The pace of technology in the semiconductor industry is such that implanters are being built now for 256 Megabit circuits but which are only likely to be widely available five years from now. Several specialist companies manufacture implanter systems, each costing around US$5 million, depending on the

  2. Quantitative ion implantation

    International Nuclear Information System (INIS)

    Gries, W.H.

    1976-06-01

    This is a report of the study of the implantation of heavy ions at medium keV-energies into electrically conducting mono-elemental solids, at ion doses too small to cause significant loss of the implanted ions by resputtering. The study has been undertaken to investigate the possibility of accurate portioning of matter in submicrogram quantities, with some specific applications in mind. The problem is extensively investigated both on a theoretical level and in practice. A mathematical model is developed for calculating the loss of implanted ions by resputtering as a function of the implanted ion dose and the sputtering yield. Numerical data are produced therefrom which permit a good order-of-magnitude estimate of the loss for any ion/solid combination in which the ions are heavier than the solid atoms, and for any ion energy from 10 to 300 keV. The implanted ion dose is measured by integration of the ion beam current, and equipment and techniques are described which make possible the accurate integration of an ion current in an electromagnetic isotope separator. The methods are applied to two sample cases, one being a stable isotope, the other a radioisotope. In both cases independent methods are used to show that the implantation is indeed quantitative, as predicted. At the same time the sample cases are used to demonstrate two possible applications for quantitative ion implantation, viz. firstly for the manufacture of calibration standards for instrumental micromethods of elemental trace analysis in metals, and secondly for the determination of the half-lives of long-lived radioisotopes by a specific activity method. It is concluded that the present study has advanced quantitative ion implantation to the state where it can be successfully applied to the solution of problems in other fields

  3. Ion implantation - an introduction

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1986-01-01

    Ion implantation is a widely used technique with a literature that covers semiconductor production, surface treatments of steels, corrosion resistance, catalysis and integrated optics. This brief introduction outlines advantages of the technique, some aspects of the underlying physics and examples of current applications. Ion implantation is already an essential part of semiconductor technology while in many other areas it is still in an early stage of development. The future scope of the subject is discussed. (author)

  4. Modificaciones en la estructura superficial y la composición química de los implantes dentales de zirconio

    OpenAIRE

    Lazo, Sergio Daniel; Lazo, Gabriel Eduardo; Escudero Giachella, Ezequiel; Bentivenga, N.; Basal, Roxana Lía; Friso, Nélida Ester; Alfaro, Gabriel Enrique; Pazos, Fernando Ezequiel; Cuchetti, Diana; Amaro, Emilio Gustavo; Ivanov, Marcela; Butler, Teresa Adela

    2015-01-01

    El objetivo de este trabajo es mostrar las modificaciones estructurales de superficie y químicas en el diseño de los implantes de zirconio, para mejorar sus propiedades biodontológicas. Para el desarrollo del mismo se utilizaron 20 implantes de zirconio con el agregado de itrio, de 5 mm de diámetro y aproximadamente 9 mm de largo. Los implantes fueron elaborados por el método de CAD CAM, con doble coc ción durante el sinterizado. Posteriormente se observó la estructura superficial con la medi...

  5. Entrevista con Giovanni Levi

    Directory of Open Access Journals (Sweden)

    Monica Oliveira

    2017-06-01

    Full Text Available En esta entrevista, Giovanni Levi - como un conocedor del tema de Familia - realiza una importante evaluación sobre el actual estado de las investigaciones realizadas en el Brasil y em el exterior. Con estilo franco, agudo y lucido critica las visiones tradicionales y sus ilusiones ypropone nuevos conceptos y métodos. La historia de la familia debería ceder espacio para el estudio de las redes relacionales o de los mundos relacionales. De la misma forma, la historia cuantitativa debería abrir espacio para el estudio de las cualidades. Ya con relación a la historia de las elites, tan estudiada y reproducida en una diversidad de trabajos, que deberíase mirar en otra perspectiva. Es decir, no mirar a las reglas sociales predeterminadas, sino a los desvíos y a las variaciones. Levi defiende que los historiadores deben trascender a los documentos que se encuentran fácilmente y que pueden fortalecer perspectivas deformadas y esequilibradas de la sociedad. Para él, los historiadores deben esforzarse por estudiar a aquellos grupos que dejaron pocos rastros documentales. En ese esfuerzo existiría una nueva mirada sobre la historia de la familia.

  6. Entrevista con Patricia Ariza

    Directory of Open Access Journals (Sweden)

    Esperanza Londoño La Rotta

    2017-01-01

    Full Text Available Pensamiento, Palabra y Obra entrevista a una artista, feminista y activista política, quien como mujer y artista ha permitido pensar el arte más allá de un simple espectáculo. Toda una vida dedicada al teatro y a darle voz, a través de sus obras, a víctimas del conflicto colombiano, defensora de derechos humanos; además de hacer evidente en su vida y a través de la plataforma “Artistas por la paz”, las múltiples relaciones que se pueden establecer entre el arte, la construcción de paz y la resolución de conflictos. Hablamos en su casa, en medio del calor de la bienvenida con Patricia Ariza, directora del festival alternativo de teatro, de Mujeres en Escena y de la Corporación Colombiana de Teatro, entre otras muchas actividades que voluntariamente su espíritu libertario ha asumido. Esta entrevista se realizó antes del 2 de octubre, pero con la revisión de los acuerdos que propició el plebiscito ganado por una ínfima minoría por el no, sigue siendo vigente este planteamiento.

  7. Contraceptive implants: current perspectives

    Directory of Open Access Journals (Sweden)

    Rowlands S

    2014-09-01

    Full Text Available Sam Rowlands,1,2 Stephen Searle3 1Centre of Postgraduate Medical Research and Education, School of Health and Social Care, Bournemouth University, Bournemouth, United Kingdom; 2Dorset HealthCare, Bournemouth, United Kingdom; 3Sexual Health Services, Chesterfield, United KingdomAbstract: Progestin-only contraceptive implants are a highly cost-effective form of long-acting reversible contraception. They are the most effective reversible contraceptives and are of a similar effectiveness to sterilization. Pregnancies are rare in women using this method of contraception, and those that do occur must be fully investigated, with an ultrasound scan of the arm and serum etonogestrel level if the implant cannot be located. There are very few contraindications to use of implants, and they have an excellent safety profile. Both acceptability and continuation with the method are high. Noncontraceptive benefits include improvements in dysmenorrhea, ovulatory pain, and endometriosis. Problematic bleeding is a relatively common adverse effect that must be covered in preinsertion information-giving and supported adequately if it occurs. Recognized training for both insertion and removal should be undertaken. Care needs to be taken at both insertion and removal to avoid neurovascular injury. Implants should always be palpable; if they are not, noninsertion should be assumed until disproven. Etonogestrel implants are now radiopaque, which aids localization. Anticipated difficult removals should be performed by specially trained experts. Keywords: contraceptive, subdermal implant, etonogestrel, levonorgestrel, progestin-only, long-acting reversible contraception

  8. Anodized dental implant surface

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Mishra

    2017-01-01

    Full Text Available Purpose: Anodized implants with moderately rough surface were introduced around 2000. Whether these implants enhanced biologic effect to improve the environment for better osseointegration was unclear. The purpose of this article was to review the literature available on anodized surface in terms of their clinical success rate and bone response in patients till now. Materials and Methods: A broad electronic search of MEDLINE and PubMed databases was performed. A focus was made on peer-reviewed dental journals. Only articles related to anodized implants were included. Both animal and human studies were included. Results: The initial search of articles resulted in 581 articles on anodized implants. The initial screening of titles and abstracts resulted in 112 full-text papers; 40 animal studies, 16 studies on cell adhesion and bacterial adhesion onto anodized surfaced implants, and 47 human studies were included. Nine studies, which do not fulfill the inclusion criteria, were excluded. Conclusions: The long-term studies on anodized surface implants do favor the surface, but in most of the studies, anodized surface is compared with that of machined surface, but not with other surfaces commercially available. Anodized surface in terms of clinical success rate in cases of compromised bone and immediately extracted sockets has shown favorable success.

  9. Plasma source ion implantation

    International Nuclear Information System (INIS)

    Conrad, J.R.; Forest, C.

    1986-01-01

    The authors' technique allows the ion implantation to be performed directly within the ion source at higher currents without ion beam extraction and transport. The potential benefits include greatly increased production rates (factors of 10-1000) and the ability to implant non-planar targets without rastering or shadowing. The technique eliminates the ion extractor grid set, beam raster equipment, drift space and target manipulator equipment. The target to be implanted is placed directly within the plasma source and is biased to a large negative potential so that plasma ions gain energy as they accelerate through the potential drop across the sheath that forms at the plasma boundary. Because the sheath surrounds the target on all sides, all surfaces of the target are implanted without the necessity to raster the beam or to rotate the target. The authors have succeeded in implanting nitrogen ions in a silicon target to the depths and concentrations required for surface treatment of materials like stainless steel and titanium alloys. They have performed ESCA measurements of the penetration depth profile of a silicon target that was biased to 30 kV in a nitrogen discharge plasma. Nitrogen ions were implanted to a depth of 700A at a peak concentration of 30% atomic. The measured profile is quite similar to a previously obtained profile in titanium targets with conventional techniques

  10. Short dental implants: an emerging concept in implant treatment.

    Science.gov (United States)

    Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Yunus, Norsiah

    2014-06-01

    Short implants have been advocated as a treatment option in many clinical situations where the use of conventional implants is limited. This review outlines the effectiveness and clinical outcomes of using short implants as a valid treatment option in the rehabilitation of edentulous atrophic alveolar ridges. Initially, an electronic search was performed on the following databases: Medline, PubMed, Embase, Cochrane Database of Systematic Reviews, and DARE using key words from January 1990 until May 2012. An additional hand search was included for the relevant articles in the following journals: International Journal of Oral and Maxillofacial Implants, Clinical Oral Implants Research, Journal of Clinical Periodontology, International Journal of Periodontics, Journal of Periodontology, and Clinical Implant Dentistry and Related Research. Any relevant papers from the journals' references were hand searched. Articles were included if they provided detailed data on implant length, reported survival rates, mentioned measures for implant failure, were in the English language, involved human subjects, and researched implants inserted in healed atrophic ridges with a follow-up period of at least 1 year after implant-prosthesis loading. Short implants demonstrated a high rate of success in the replacement of missing teeth in especially atrophic alveolar ridges. The advanced technology and improvement of the implant surfaces have encouraged the success of short implants to a comparable level to that of standard implants. However, further randomized controlled clinical trials and prospective studies with longer follow-up periods are needed.

  11. El juego como vehículo para mejorar las habilidades de lectura en niños con dificultad lectora

    Directory of Open Access Journals (Sweden)

    Natalia Cadavid Ruiz

    2014-01-01

    Full Text Available A partir de las escasas propuestas de intervención de la lectura en población infantil colombiana, el presente estudio tiene por objetivo evaluar el impacto de un programa de intervención de la lectura, centrado en juego y aprendizaje implícito, sobre el desempeño lector en niños con dificultades lectoras, inmediatamente después y seis meses posteriores a la aplicación del programa. Método. Por medio de un diseño cuasi - experimental, transversal y comparativo, se evaluaron 20 niños, entre los 7 y 9 años de edad, con un desarrollo psicológico típico, quienes asistían regularmente a un colegio público de la ciudad de Cali (Colombia. Las evaluaciones pre y post incluyeron la aplicación de pruebas que exploran conciencia fonológica, capacidad lectora y rendimiento cognitivo general. Estos datos se emplearon para calcular diferencias entre los desempeños de los niños, obtenidos en la preintervención, posintervención inmediata y a largo plazo. Resultados. Los datos recogidos demostraron que los niños mejoran significativamente su rendimiento lector inmediatamente después de la aplicación del programa, con un efecto que se mantiene a largo plazo. Conclusión. Las dificultades lectoras que presentan los niños participantes pueden mejorarse con la aplicación de un programa de intervención de la lectura, centrado en el juego y aprendizaje implícito.

  12. Reproducción in vitro de la biopelícula de mucositis sobre implantes de zirconio

    OpenAIRE

    Spina, Marianela; Butler, Teresa Adela; Lazo, Sergio Daniel; Escudero Giachella, Ezequiel; Friso, Nélida Ester; Basal, Roxana Lía; Bentivegna, Nicolás; Amaro, Emilio Gustavo; Pazos, Fernando Ezequiel; Alfaro, Gabriel Enrique; Ivanov, Marcela; Cuchetti, Diana; Merlo, Diego; Viscovick, Cristina

    2017-01-01

    La mucositis, causada por formas cocoides y Actinomyces, es una patología que se observa con frecuencia en los implantes de titanio. Sin embargo, aún no se ha reportado la presencia de estos microorganismos sobre los implantes de zirconio. El objetivo de este trabajo es examinar la presencia de la biopelícula de mucositis adherida a los implantes Zirconio, a través de la observación por Microscopía Electrónica de Barrido (MEB). Para este trabajo se utilizaron 10 cápsulas de Petri con Agar Mit...

  13. RECONSTRUCCIÓN DEL MAXILAR SUPERIOR POSTERIOR ATRÓFICO CON CÉLULAS MADRE MESENQUIMALES

    OpenAIRE

    Martí Pagès, Carles

    2009-01-01

    Se realiza un estudio clínico en el lnstituto de Cirugía Maxilofacial e Implantologia tras pasar el comité ético del Centro Medica Teknon. Es un estudio randomizado, controlado utilizando un diseño tipo "split mouth" en el cual cada paciente sirve de propio control. SE realiza a 5 pacientes, con atrofia posterior del maxilar superior sin posibilidad de instalar implantes fueron tratados con reconstrucción mediante la técnica de elevación sinusal bilateral, rellenando un sena con Bio-as...

  14. Capítulo 15. Seguimiento al paciente con dispositivos de estimulación cardiaca

    Directory of Open Access Journals (Sweden)

    Clara I. Saldarriaga

    2016-03-01

    Conclusión: Los pacientes con cardiorresincronizador y desfibrilador implantable deben seguirse en clínicas de falla cardiaca para garantizar la adecuada selección de los candidatos y la optimización de la terapia.

  15. preescolares desnutridos con madres con obesidad y sin obesidad

    Directory of Open Access Journals (Sweden)

    Viridiana Vanessa Conzuelo-González

    2009-01-01

    Full Text Available El primer objetivo fue conocer cuántos menores de cinco años con diferentes grados de desnutrición tienen una madre con sobrepeso/obesidad/ en una comunidad indígena que vive en extrema pobreza y bajo condiciones de migración masculina internacional. El segundo fue comparar tres variables socionutricionales (ingreso familiar, educación de la madre y adecuación nutrimental de la dieta diaria entre estos hogares y los hogares con desnutrición infantil y madres sin obesidad. Se realizó un estudio transversal (2006-2007, en la comunidad mazahua de San Francisco Tepeolulco, Municipio de Temascalcingo; que incluyó a 85 hogares integrados por preescolares con desnutrición inscritos al programa Oportunidades. Se determinó el estado nutrición de los preescolares con indicadores antropométricos y se obtuvo el IMC de las madres de estos infantes. Se aplicó una encuesta socionutricional, incluida el recordatorio de 24 horas, y complementado con la observación participante (cualitativa. Se encontró que 83% de las madres mazahuas presentaron sobrepeso u obesidad. El estado de nutrición de los preescolares con madres con obesidad presentó un porcentaje mayor de desnutrición (76%. En la variable género, se encontró que 54% de los niños con madres con obesidad tenía baja talla. Al relacionar el nivel educativo de la madre, esta variable resultó ser estadísticamente significativa (p=0.015, donde el analfabetismo está más relacionado con la desnutrición infantil que tienen madres de bajo y/o peso normal. La elevada prevalencia de hogares conformados con preescolares con desnutrición y madres con obesidad, es un síntoma más de la pobreza en zonas indígenas en México, con bajo índice de desarrollo humano.

  16. [Bilateral cochlear implants].

    Science.gov (United States)

    Müller, J

    2017-07-01

    Cochlear implants (CI) are standard for the hearing rehabilitation of severe to profound deafness. Nowadays, if bilaterally indicated, bilateral implantation is usually recommended (in accordance with German guidelines). Bilateral implantation enables better speech discrimination in quiet and in noise, and restores directional and spatial hearing. Children with bilateral CI are able to undergo hearing-based hearing and speech development. Within the scope of their individual possibilities, bilaterally implanted children develop faster than children with unilateral CI and attain, e.g., a larger vocabulary within a certain time interval. Only bilateral implantation allows "binaural hearing," with all the benefits that people with normal hearing profit from, namely: better speech discrimination in quiet and in noise, as well as directional and spatial hearing. Naturally, the developments take time. Binaural CI users benefit from the same effects as normal hearing persons: head shadow effect, squelch effect, and summation and redundancy effects. Sequential CI fitting is not necessarily disadvantageous-both simultaneously and sequentially fitted patients benefit in a similar way. For children, earliest possible fitting and shortest possible interval between the two surgeries seems to positively influence the outcome if bilateral CI are indicated.

  17. Psychological intervention following implantation of an implantable defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Sears, Samuel F

    2007-01-01

    The medical benefits of the implantable cardioverter defibrillator (ICD) are unequivocal, but a subgroup of patients experiences emotional difficulties following implantation. For this subgroup, some form of psychological intervention may be warranted. This review provides an overview of current ...

  18. Mecanobiología de la interfase hueso-implante dental

    Directory of Open Access Journals (Sweden)

    Juan Carlos Vanegas Acosta

    2010-03-01

    Full Text Available La osteointegración es la conexión estructural y funcional entre el hueso y un implante. Cuando un implante se inserta en el hueso, se crea la denominada interfase hueso-implante, una zona de unión entre la superficie del biomaterial del implante y el hueso circundante. La cicatrización de esta interfase depende de las condiciones biológicas del hueso, las características de diseño del implante y la distribución de cargas entre hueso e implante. En este artículo se hace una revisión del proceso de cicatrización de la interfase hueso-implante para el caso de un implante dental. El objetivo es describir la secuencia de eventos biológicos iniciados con la lesión causada por la inserción del implante y que concluyen con la formación de nuevo hueso en la interfase. Esta descripción incluye una novedosa clasificación de los fenómenos mecánicos que intervienen durante el proceso de cicatrización de los tejidos lesionados. Esta descripción mecanobiológica de la interfase hueso-implante dental se utiliza para determinar las características más relevantes a tener en cuenta en la formulación de un modelo matemático de la osteointegración de implantes dentales.

  19. Fracturas de implantes de tibia. Consecuencias para los ensayos de los implantes

    OpenAIRE

    Frei, S.; Ploeg, H.; Reinschmidt, C.; Heuberger, P.

    1999-01-01

    El objetivo de este trabajo es estudiar los modelos de fracturas de prótesis de tibia descritos en la literatura y, sobre la base de dichos conocimientos, desarrollar un ensayo para implantes en la cual se logren simular condiciones fisiológicas. El caso descrito con mayor frecuencia en la literatura es la migración de la parte medial de la prótesis, fenómeno que, a menudo, antecede a la fractura de la prótesis. La posición defectuosa resultante de dicha migración modifica el eje ...

  20. Management of peri-implantitis

    Directory of Open Access Journals (Sweden)

    Jayachandran Prathapachandran

    2012-01-01

    Full Text Available Peri-implantitis is a site-specific infectious disease that causes an inflammatory process in soft tissues, and bone loss around an osseointegrated implant in function. The etiology of the implant infection is conditioned by the status of the tissue surrounding the implant, implant design, degree of roughness, external morphology, and excessive mechanical load. The microorganisms most commonly associated with implant failure are spirochetes and mobile forms of Gram-negative anaerobes, unless the origin is the result of simple mechanical overload. Diagnosis is based on changes of color in the gingiva, bleeding and probing depth of peri-implant pockets, suppuration, X-ray, and gradual loss of bone height around the tooth. Treatment will differ depending upon whether it is a case of peri-implant mucositis or peri-implantitis. The management of implant infection should be focused on the control of infection, the detoxification of the implant surface, and regeneration of the alveolar bone. This review article deals with the various treatment options in the management of peri-implantitis. The article also gives a brief description of the etiopathogenesis, clinical features, and diagnosis of peri-implantitis.

  1. Ion implantation control system

    International Nuclear Information System (INIS)

    Gault, R. B.; Keutzer, L. L.

    1985-01-01

    A control system is disclosed for an ion implantation system of the type in which the wafers to be implanted are mounted around the periphery of a disk which rotates and also moves in a radial direction relative to an ion beam to expose successive sections of each wafer to the radiation. The control system senses beam current which passes through one or more apertures in the disk and is collected by a Faraday cup. This current is integrated to obtain a measure of charge which is compared with a calculated value based upon the desired ion dosage and other parameters. The resultant controls the number of incremental steps the rotating disk moves radially to expose the adjacent sections of each wafer. This process is continued usually with two or more traverses until the entire surface of each wafer has been implanted with the proper ion dosage

  2. Implantation for tribological applications

    International Nuclear Information System (INIS)

    Leutenecker, R.; Cao-Minh, U.; Overbeck, R.

    1992-08-01

    Empirical results on the strength enhancement of steels by N- and B-implantation should be explained from a materials science point of view. The methods applied were X-ray diffractometry and element depth profiling. The investigations of N-implanted steels focussed on the nitride formation in selected model materials and, with respect to applications, in: X90 CrMoV and S 6-5-2 tool steels, austenite X10 CrNiTi189 as well as in hard chromium plates. Main topic in B-implanted steels were the transformations: crystalline Fe-phase - amorphous Fe-B-phase - crystalline boride phases. The result is an improvement in process control by first an insight into the strength enhancing mechanisms and second in into their generation depending on the materials microstructure and the process parameter. (orig.). 101 figs., 16 tabs., 15 refs [de

  3. Dental implants: A review.

    Science.gov (United States)

    Guillaume, B

    2016-12-01

    A high number of patients have one or more missing tooth and it is estimated that one in four American subjects over the age of 74 have lost all their natural teeth. Many options exist to replace missing teeth but dental implants have become one of the most used biomaterial to replace one (or more) missing tooth over the last decades. Contemporary dental implants made with titanium have been proven safe and effective in large series of patients. This review considers the main historical facts concerned with dental implants and present the different critical factors that will ensure a good osseo-integration that will ensure a stable prosthesis anchorage. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  4. Postpartum suppression of ovarian activity with a Deslorelin implant enhanced uterine involution in lactating dairy cows.

    Science.gov (United States)

    Silvestre, F T; Bartolome, J A; Kamimura, S; Arteche, A C; Pancarci, S M; Trigg, T; Thatcher, W W

    2009-01-01

    Holstein cows received, subcutaneously a non-degradable implant containing 5mg of the GnRH agonist Deslorelin (DESL) or no implant (CON) at 2+/-1 days postpartum (dpp). All cows were injected with PGF(2alpha) at 9 dpp. Previous pregnant (PPH) and non-pregnant uterine horns (PNPH) were determined by palpation per rectum. In Experiment 1, cows [DESL implant (n=10) and CON (n=9)] were examined by ultrasonography to record ovarian structures (23, 30 and 37 dpp) and uterine horn and cervical diameters (16, 23, 30 and 37 dpp). Uterine tone was scored before ultrasonography. Vaginoscopy was conducted just after ultrasonography examination to assess cervical discharge and color of the external cervical os. Blood samples were collected on a weekly basis for hormonal analyses. In Experiment 2, cows [DESL implant (n=77) and CON (n=70)] were palpated per rectum and vaginoscopy at 30 dpp for scoring of uterine tone, uterine horns, cervical diameter, and discharge. Blood samples were collected only at 9 dpp. In Experiment 1, DESL-implant-treated cows had more Class 1 follicles (Pscore did not differ between treatments. Treatment with non-degradable Deslorelin (5mg) implant during postpartum: (1) suppressed ovarian follicular development, (2) enhanced physical involution of the uterus and cervix, (3) increased tone of the uterine wall, (4) decreased frequency of purulent cervical discharges, and (5) reduced inflammatory processes of the reproductive tract.

  5. autorregulado con estudiantes universitarios

    Directory of Open Access Journals (Sweden)

    Jairo Andrés Montes

    2005-01-01

    Full Text Available El propósito del presente estudio es describir la forma en la que se presentan los procesos de aprendizaje autorregulado con un grupo de estudiantes (22 estudiantes de tercer semestre de Psicología de la PUJ, Cali, en el evento de preparación para la presentación un examen. Asimismo se describen las correlaciones que ocurren entre las distintas fases de dicho proceso de autorregulación del aprendizaje. Para conseguir los objetivos propuestos se ha hecho uso de una observación de desempeño en tiempo real, es decir, de la observación durante una sesión de preparación de examen de los estudiantes, en la cual se emplearon protocolos verbales para dar cuenta de lo que «pasaba por su mente» mientras estudiaban. Una entrevista semi-estructurada y una prueba objetiva. Los resultados fueron analizados a la luz del modelo mixto de procesamiento de información y constructivismo abordado por Winne(1998. Como resultado se encontró una relación significativa entre los niveles de desempeño en el proceso de ARR y el resultado del examen. Igualmente se encontraron bajos niveles de regulación en una parte importante de la muestra y un desfase significativo entre conocimiento declarativo de ARR y desempeño en el mismo

  6. Tribology of implantation bilayers

    International Nuclear Information System (INIS)

    Pivin, J.C.

    1989-01-01

    The mechanical behaviour of implantation films must be analysed in terms of bilayer rheology (laws of mechanical behaviour). Tribology takes into account thermodynamical, chemical and metallurgical parameters to interpret the friction properties of a system as a whole. One can distinguish between alloying effects of ion implantation and structural modifications. Alloying affects the basic properties of the crystal: elasticity, cohesion, mobility of planar defects, and its surface electronic structure, which determines the reactivity with the atmosphere or the friction counterpart (adhesion). Radiation damage and phase changes act more particularly on the modes of gliding and climbing of dislocations, and fracture mechanisms. 105 refs.; 11 figs.; 1 table

  7. [Tinnitus and implants].

    Science.gov (United States)

    Despreaux, G; Tison, P; Van Den Abbeele, T; Moine, A; Frachet, B

    1990-01-01

    The experience with cochlear implantation at Avicenne hospital prompted us to carry out a retrospective study on tinnitus in a population of operated patients. Improvement or disappearance of the symptoms was noted in all cases. These results, which partly match those found in the literature, are probably produced by rehabilitation inhibiting the "deafferentation" mechanisms in analogy with pain phenomena. In some precise cases, which are described, they led us to proposing implantation even though the main, if not sole, complaint of the patient was tinnitus.

  8. Fracaso en los implantes dentales: Fibrointegración. Reporte de caso clínico

    Directory of Open Access Journals (Sweden)

    Iris Luz Santís Chamorro

    2014-06-01

    Full Text Available  ResumenLa rehabilitación con implantes dentales en los pacientes con edentulismo parcial o total posee amplias indicaciones que se ven limitadas por factores anatómicos y biológicos. La oseointegración surge como un hecho descubierto entre la adaptación biológica del hueso a la superficie del titanio del implante (interfase hueso-implante por lo que se afirma que el motivo de fracaso de la mayoría de los sistemas de implantes es que éstos se encapsulen en un tejido de cicatrización fibroso (fibrointegración mal diferenciado lo que crea movilidad, que lleva a reacciones en la mucosa y finalmente a la pérdida. El objetivo del presente artículo es promover la presentación de casos clínicos de pacientes con fracaso de implantes dentales, con el ánimo de esclarecer las posibles causas y los factores coadyuvantes de dicho fracaso, y así mejorar los resultados en implantología. (Duazary 2008; 115-120AbstractThe rehabilitation with dental implants in the patients with partial absence or total of teeth possesses extensive indications that are seen limited by biological and anatomical factors. The oseointegration arises like a discovered fact among the biological adaptation of the bone to the surface of the titanic of the implant (interface bone-implant for which it is affirmed that the motive of failure of the majority of the systems of implants is that these it self envelop in a scar formation of fibrous tissue (Fibrointegration badly differentiated what creates mobility, that carries to reactions in the mucous membrane and finally to the loss. The objective of the present article is to promote the presentation of patients' clinical cases with failure of dental implants, with the intention of clarifying the possible reasons and the helping factors of the above mentioned failure, and this way to improve the results in implantology.Key Words: Fibrointegration; oseointegration; dentals implants; interface; implants failure.

  9. Recent advances in dental implants.

    Science.gov (United States)

    Hong, Do Gia Khang; Oh, Ji-Hyeon

    2017-12-01

    Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.

  10. Untreated silicone breast implant rupture

    DEFF Research Database (Denmark)

    Hölmich, Lisbet R; Vejborg, Ilse M; Conrad, Carsten

    2004-01-01

    Implant rupture is a well-known complication of breast implant surgery that can pass unnoticed by both patient and physician. To date, no prospective study has addressed the possible health implications of silicone breast implant rupture. The aim of the present study was to evaluate whether untre...

  11. Puentes con vigas pretensadas

    Directory of Open Access Journals (Sweden)

    Editorial, Equipo

    1965-07-01

    Full Text Available This paper describes one of the three bridges which Hidrocivil, S. A., has built in Catalonia (northern Spain, over the river Ripoll. The other two bridges are very similar to this one, both in construction and design, and show only minor adjustments to the local topography. The contracting firm proposed several alterations in the prefabrication and constructional procedure, in relation to the initial project, and these changes were accepted. The main feature of these projects is the use of prestressed beams, built at the workshop in sections, and joined together by means of sixty 7 mm cables in each beam. As the shear forces are more acute at the joints, the end of each section has a kind of diaphragm, to provide a large contact area, and hence greater surface to transmit the shear forces. The methods of construction are also of interest. Briefly, they involve building the bridge piles, and use these to support a provisional structure with transversal movement. This provisional structure, in turn, served as platform for two bridge cranes, which lifted the girders to their final location. After the first span was completed, the deck was concreted and the auxiliary structure pushed forward to the next span, to repeat the same operations. This arrangement saved the use of provisional framework.En este trabajo se describe uno de los tres puentes que Hidrocivil, S. A., ha construido.—previo concurso— en la región catalana; concretamente, el que salva el río Ripoll. Los otros dos no han sido objeto de descripción general por ser muy similares, en lo que a ejecución y concepción se refiere, con la única variante que presentan las características topográficas locales. La empresa propuso ciertas variantes— que fueron aceptadas— en la prefabricación y métodos de construcción. El interés de estas obras se centra en el empleo de vigas pretensadas, prefabricadas en taller por trozos, y solidarizados en el mismo mediante las operaciones

  12. Two-stage implant systems.

    Science.gov (United States)

    Fritz, M E

    1999-06-01

    Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of

  13. Asistencia miocárdica con matrices bioartificiales

    Directory of Open Access Journals (Sweden)

    Jorge C. Trainini

    2006-01-01

    Full Text Available El objetivo de la cardiomioplastia celular es regenerar el miocardio mediante el implante de células vivas. Sin embargo, en corazones isquémicos hay alteraciones en la matriz extracelular. El colágeno tipo I, responsable del soporte estructural, disminuye desde el 80% al 40%, mientras que el colágeno tipo III aumenta del 10% al 35%. De esta manera, se hace importante asociar las células implantadas con una matriz extracelular bioartificial. El propósito de esta revisión es evaluar la performance de las células junto con una matriz biodegradable ubicadas en la superficie ventricular izquierda.

  14. Violencia con el anciano

    Directory of Open Access Journals (Sweden)

    Rita Campillo Motilva

    2002-08-01

    Full Text Available La violencia doméstica es tan antigua como la humanidad misma y se reconocen la violencia infantil, contra la mujer y al anciano, fundamentalmente; siendo este último grupo una población en ascenso por las mayores expectativas de vida de los últimos años. Como resultado de ello, el número de casos de abuso en el anciano se incrementará y el impacto de este abuso sobre la salud debe ser considerado de forma adecuada. La gama de maltratos es variadísima e incluye el abuso físico, emocional, financiero, sexual, por negligencia, negación a brindarle ayuda y otras formas más. Los ancianos con deterioro cognitivo son los más vulnerables. El médico en la atención primaria de salud es un pilar importante en la prevención y educación de este problema.Domestic violence is as old as humanity itself. Child, women and elderly abuse are mainly recognized. The elderly group is increasing due to the higher life expectancy experimented during the last years. As a result, the number of battered elderly will grow and the impact of this abuse on health should be adequately considered. The range of abuse is very wide and it includes physical, emotional, financial and sexual abuse, negligence, rejection to give assistance and others. The elderly with cognitive deterioration are the most vulnerable. The physician at the primary health care level is an important milestone in the prevention and education of this problem.

  15. Semiconductor Ion Implanters

    International Nuclear Information System (INIS)

    MacKinnon, Barry A.; Ruffell, John P.

    2011-01-01

    In 1953 the Raytheon CK722 transistor was priced at $7.60. Based upon this, an Intel Xeon Quad Core processor containing 820,000,000 transistors should list at $6.2 billion! Particle accelerator technology plays an important part in the remarkable story of why that Intel product can be purchased today for a few hundred dollars. Most people of the mid twentieth century would be astonished at the ubiquity of semiconductors in the products we now buy and use every day. Though relatively expensive in the nineteen fifties they now exist in a wide range of items from high-end multicore microprocessors like the Intel product to disposable items containing 'only' hundreds or thousands like RFID chips and talking greeting cards. This historical development has been fueled by continuous advancement of the several individual technologies involved in the production of semiconductor devices including Ion Implantation and the charged particle beamlines at the heart of implant machines. In the course of its 40 year development, the worldwide implanter industry has reached annual sales levels around $2B, installed thousands of dedicated machines and directly employs thousands of workers. It represents in all these measures, as much and possibly more than any other industrial application of particle accelerator technology. This presentation discusses the history of implanter development. It touches on some of the people involved and on some of the developmental changes and challenges imposed as the requirements of the semiconductor industry evolved.

  16. Implantable enzyme amperometric biosensors.

    Science.gov (United States)

    Kotanen, Christian N; Moussy, Francis Gabriel; Carrara, Sandro; Guiseppi-Elie, Anthony

    2012-05-15

    The implantable enzyme amperometric biosensor continues as the dominant in vivo format for the detection, monitoring and reporting of biochemical analytes related to a wide range of pathologies. Widely used in animal studies, there is increasing emphasis on their use in diabetes care and management, the management of trauma-associated hemorrhage and in critical care monitoring by intensivists in the ICU. These frontier opportunities demand continuous indwelling performance for up to several years, well in excess of the currently approved seven days. This review outlines the many challenges to successful deployment of chronically implantable amperometric enzyme biosensors and emphasizes the emerging technological approaches in their continued development. The foreign body response plays a prominent role in implantable biotransducer failure. Topics considering the approaches to mitigate the inflammatory response, use of biomimetic chemistries, nanostructured topographies, drug eluting constructs, and tissue-to-device interface modulus matching are reviewed. Similarly, factors that influence biotransducer performance such as enzyme stability, substrate interference, mediator selection and calibration are reviewed. For the biosensor system, the opportunities and challenges of integration, guided by footprint requirements, the limitations of mixed signal electronics, and power requirements, has produced three systems approaches. The potential is great. However, integration along the multiple length scales needed to address fundamental issues and integration across the diverse disciplines needed to achieve success of these highly integrated systems, continues to be a challenge in the development and deployment of implantable amperometric enzyme biosensor systems. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. HA-Coated Implant

    DEFF Research Database (Denmark)

    Daugaard, Henrik; Søballe, Kjeld; Bechtold, Joan E

    2014-01-01

    of improving the fixation of implants. Of these, hydroxyapatite (HA) is the most widely used and most extensively investigated. HA is highly osseoconductive, and the positive effect is well documented in both basic and long-term clinical research [1–6]. This chapter describes experimental and clinical studies...

  18. Middle ear implants

    Directory of Open Access Journals (Sweden)

    K S Gangadhara Somayaji

    2013-01-01

    Full Text Available Hearing loss is becoming more common in the society living in cities with lot of background noise around, and frequent use of gadgets like mobile phones, MP3s, and IPods are adding to the problem. The loss may involve the conductive or perceptive pathway. Majority of the patients with conductive hearing loss will revert back to normal hearing levels with medical and/or surgical treatment. However, in sensorineural hearing loss, many factors are involved in the management. Though traditionally hearing aids in various forms are the most commonly used modality in managing these patients, there are some drawbacks associated with them. Implantable middle ear amplifiers represent the most recent breakthrough in the management of hearing loss. Middle ear implants are surgically implanted electronic devices that aim to correct hearing loss by stimulating the ossicular chain or middle ear. Of late, they are also being used in the management of congenital conductive hearing loss and certain cases of chronic otitis media with residual hearing loss. The article aims to provide general information about the technology, indications and contraindications, selection of candidates, available systems, and advantages of middle ear implants. (MEI

  19. Delayed breast implant reconstruction

    DEFF Research Database (Denmark)

    Hvilsom, Gitte B.; Hölmich, Lisbet R.; Steding-Jessen, Marianne

    2011-01-01

    the period 1999 to 2006; 239 one-stage procedures and 353 two-stage procedures. The postoperative course through November 2009 was evaluated by cumulative incidence adjusting for competing risks for the selected outcomes; hematoma, infection, seroma, implant rupture, severe capsular contracture (modified...

  20. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  1. Características clínico-epidemiológicas de pacientes con cólera en la ciudad de México

    Directory of Open Access Journals (Sweden)

    Vilchis-Guizar Agustina Elena

    1999-01-01

    Full Text Available OBJETIVO: Comparar las características clínico-epidemiológicas de enfermos de cólera (casos con las de pacientes con diarrea por otra causa (no casos, atendidos en las unidades médicas de la Delegación 2 Noreste del Distrito Federal, del Instituto Mexicano del Seguro Social (IMSS. MATERIAL Y MÉTODOS: Se realizó un estudio transversal analítico y se utilizaron datos de 4 952 notificaciones reunidas entre 1995 y 1998 a través del formato oficial "Hoja de notificación inmediata de casos de cólera", que cada unidad médica envía a la Coordinación de Salud Comunitaria del IMSS. Mediante estadística analítica se compararon medias y proporciones para ambos grupos. RESULTADOS: Se identificaron 588 pacientes con cólera y 4 364 con diarrea por otra causa. En el primer grupo, la edad promedio varió entre los 39 y los 51 años, y predominó el sexo femenino (54%. Durante 1995 y 1997 (años en los que se presentó un número más elevado de casos, los pacientes de cólera, en relación con el grupo de comparación, presentaron una mayor frecuencia de evacuaciones líquidas (97 vs. 73%, con aspecto de "agua de arroz" (31 vs. 13%, vómitos (72 vs. 63%, espasmos musculares (49 vs. 26%, deshidratación (83 vs. 71%, choque hipovolémico (10 vs. 1% y defunciones (0.85% vs. 0.25%, con diferencias estadísticamente significativas. CONCLUSIONES: El cólera muestra un comportamiento cíclico bianual; a mayor frecuencia mayor gravedad de la enfermedad. Se requiere incrementar la vigilancia epidemiológica y el esfuerzo médico para un diagnóstico y tratamiento oportuno.

  2. Effectiveness of the radio sterilized amniotic membrane transplantation vs conjunctival auto graft implant in the pterygium surgery with intraoperative mitomycin C;Eficacia del trasplante de membrana amniotica radioesterilizada vs injerto autologo conjuntival en la cirugia de pterigion con mitocomina C intraoperatoria

    Energy Technology Data Exchange (ETDEWEB)

    Tellez Y, L.; Martinez P, M. E. [ININ, Banco de Tejidos Radioesterilizados, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico); Vazquez M, L. [Hospital General de Mexico, Departamento de Cornea, Dr. Balmis No. 148, Col. Doctores, 06726 Mexico D. F. (Mexico)

    2009-07-01

    At the present time the traditional surgical handling of the pterygium with conjunctival implant presents high frequency. In this work the obtained results of a controlled clinic practice blind double are presented of the period of December from 2008 to December 2009, realized in the Medical Unit of Ambulatory Attention 231 of the Mexican Institute of the Public Health located in Metepec, Mexico State, in order to demonstrate the effectiveness and security of the alternative use of the radio sterilized amniotic membrane and intraoperative mitomycin C. For the study was included patients with diagnostic of primary nasal pterygium in one or both eyes, adults of both genus with an age range of 20 to 60 years, and was used radio sterilized amniotic membrane processed in the Bank of Radio Sterilized Tissues of the National Institute of Nuclear Research. (Author)

  3. Tratamiento ambulatorio del paciente con neutropenia febril Outpatient therapy in patients with febrile neutropenia

    Directory of Open Access Journals (Sweden)

    Andrés Londoño Gallo

    2008-01-01

    Full Text Available

    El tratamiento de los pacientes con neoplasia y neutropenia febril plantea muchas dudas. Una de ellas, que genera ansiedad en el personal de la salud, el paciente y sus familiares, es la necesidad de hospitalización porque ésta implica exponer a gérmenes intrahospitalarios potencialmente resistentes a un paciente cuyo sistema inmune puede no estar en las mejores condiciones; incluso con un aislamiento óptimo existe el riesgo de adquirir una infección nosocomial. Muchos estudios han tratado de validar métodos para clasificar a los pacientes con fiebre y neutropenia en grupos de diferente riesgo, como fundamento para implementar estrategias de tratamiento selectivo; así se ha abierto la posibilidad de utilizar medidas más conservadoras para el tratamiento de los episodios de bajo riesgo, entre ellas la administración de regímenes orales ambulatorios de antibióticos de amplio espectro; ello sin demeritar la necesidad de aplicar un juicio clínico adecuado, hacer un buen seguimiento y tener acceso a la atención médica inmediata. La neutropenia es una de las consecuencias graves de la quimioterapia para el cáncer, y se ha demostrado que el tratamiento del paciente neutropénico febril con antibióticos intravenosos reduce la mortalidad. La terapia oral podría ser una alternativa aceptable para pacientes bien seleccionados. Ella puede mejorar la calidad de vida de los pacientes con cáncer, evitar las complicaciones asociadas con la terapia intravenosa y disminuir los costos del tratamiento.

    Treatment of patients with neoplasia and febrile neutropenia, as a consequence of chemotherapy, poses many doubts, among them the need for hospitalization, since this implies exposure to potentially resistant nosocomial microorganisms. Even under the best isolation techniques, there may

  4. Lipoestructura y relleno del polo superior de la mama frente a implantes Structural fat graft and lipofilling of mammary upper pole versus mammary implants

    Directory of Open Access Journals (Sweden)

    J.M. Cervilla Lozano

    2012-09-01

    Full Text Available La lipoestructura mamaria ofrece nuevas alternativas de tratamiento en la cirugía estética de aumento mamario, cumpliendo en algunos casos las expectativas esperadas y en otros no. Analizamos este hecho en 4 tipos de aplicación de lipoestructura mamaria que hemos venido realizando en los últimos años, centrándonos en un aspecto importante de esta cirugía que es el relleno del polo superior de la mama. Los tipos de aplicación empleados son: aumento mamario simple mediante lipoestructura en comparación con implantes; pexia más lipoestructura frente a pexia más implantes mamarios; reconstrucción de mama tuberosa mediante lipoestructura o implantes y finalmente, relleno periprotésico mediante lipoestructura en mamas sometidas a cirugía de aumento mamario con implantes. En definitiva, podríamos resumir este trabajo en una frase diciendo que la lipoestructura mamaria, a nuestro juicio, no sirve si lo que prima es conseguir el relleno del polo superior de la mama, siendo en este caso de elección la colocación de implantes mamarios. No obstante, en alguno de los casos señalados no solo es una alternativa, sino que obtiene resultados superiores a los logrados sólamente con implantes.The mammary structural fat graft offers news treatment options in breast augmentation cosmetic surgery, but it sometimes meets expectations and sometimes doesn´t. We analyze 4 different types of lipostructure mammary applications that we have been using in the last years, focused in an important aspect of this surgery as it´s the filling of the upper mammary pole. These applications are: mammary augmentation by simple structural fat compared with the use of mammary implants; structural fat graft and mastopexy versus implants and mastopexy; tuberous breast reconstruction using structural fat graft or implants and finally, periprosthetic filling in breast augmentation with mammary implants using structural fat graft. In short, we could summarize this paper

  5. Efter cochlear implant

    DEFF Research Database (Denmark)

    Højen, Anders

    Dit barn har netop fået et cochlear implant. Hvad nu? Skal barnet fokusere udelukkende på at lære talt sprog, eller skal det også lære/fortsætte med tegnsprog eller støttetegn? Det er et vanskeligt spørgsmål, og før valget foretages, er det vigtigt at vurdere hvilke konsekvenser valget har, dels...... for den sproglige udvikling isoleret set, og dels for barnets udvikling ud fra en helhedsbetragtning. Dette indlæg fokuserer på, hvilke forventninger man kan have til cochlear implant-brugeres sproglige udvikling med talt sprog alene, hhv. med to sprog (tale og tegn). Disse forventninger er baseret på...

  6. Delayed breast implant reconstruction

    DEFF Research Database (Denmark)

    Hvilsom, Gitte B.; Hölmich, Lisbet R.; Steding-Jessen, Marianne

    2012-01-01

    We evaluated the association between radiation therapy and severe capsular contracture or reoperation after 717 delayed breast implant reconstruction procedures (288 1- and 429 2-stage procedures) identified in the prospective database of the Danish Registry for Plastic Surgery of the Breast during...... of radiation therapy was associated with a non-significantly increased risk of reoperation after both 1-stage (HR = 1.4; 95% CI: 0.7-2.5) and 2-stage (HR = 1.6; 95% CI: 0.9-3.1) procedures. Reconstruction failure was highest (13.2%) in the 2-stage procedures with a history of radiation therapy. Breast...... reconstruction approaches other than implants should be seriously considered among women who have received radiation therapy....

  7. Piezosurgery in implant dentistry

    Science.gov (United States)

    Stübinger, Stefan; Stricker, Andres; Berg, Britt-Isabelle

    2015-01-01

    Piezosurgery, or the use of piezoelectric devices, is being applied increasingly in oral and maxillofacial surgery. The main advantages of this technique are precise and selective cuttings, the avoidance of thermal damage, and the preservation of soft-tissue structures. Through the application of piezoelectric surgery, implant-site preparation, bone grafting, sinus-floor elevation, edentulous ridge splitting or the lateralization of the inferior alveolar nerve are very technically feasible. This clinical overview gives a short summary of the current literature and outlines the advantages and disadvantages of piezoelectric bone surgery in implant dentistry. Overall, piezoelectric surgery is superior to other methods that utilize mechanical instruments. Handling of delicate or compromised hard- and soft-tissue conditions can be performed with less risk for the patient. With respect to current and future innovative surgical concepts, piezoelectric surgery offers a wide range of new possibilities to perform customized and minimally invasive osteotomies. PMID:26635486

  8. Acne polimorfo: tratamiento con Implacen

    Directory of Open Access Journals (Sweden)

    Rubén Pérez Armas

    1995-06-01

    Full Text Available Se realiza el estudio de 40 pacientes con acné polimorfo, los que fueron atendidos en la Consulta de Dermatología del Hospital Provincial Clinicoquirúrgico Docente "Celia Sánchez Manduley", en el período comprendido de enero de 1988 a diciembre de 1989. Se revisa la literatura médica sobre los diversos métodos y medicamentos utilizados en la terapéutica de esta dermatosis. Se describe el esquema de tratamiento empleado con implacén en 30 pacientes; los 10 restantes se trataron con placebo; se compara dicho esquema con los tradicionales y se observan mejores resultados con nuestro estudio. Se destaca la ausencia de recaídas, así como el resultado del tratamiento de acuerdo con el sexo.A study was performed in 40 patients presenting with polymorphic acne who were attended in the Dermatology Department of "Celia Sánchez Manduley" Clinicosurgical and Teaching Hospital from January, 1988 to December, 1989. A review of the literature was made seeking for the different methods and drugs used for the treatment of this dermatosis. The treatment schedule with the use of implacen in 30 patients is described. Such therapeutic schedule was compared with traditional ones and better results were observed with the use of implacen. The fact that there were no relapses is highlighted, as well as the result of treatment according to sex.

  9. Ion implantation in metals

    International Nuclear Information System (INIS)

    Vook, F.L.

    1977-02-01

    The application of ion beams to metals is rapidly emerging as a promising area of research and technology. This report briefly describes some of the recent advances in the modification and study of the basic properties of metals by ion implantation techniques. Most of the research discussed illustrates some of the new and exciting applications of ion beams to metals which are under active investigation at Sandia Laboratories, Albuquerque

  10. Osteosíntesis de fractura de tobillo. Análisis evolutivo con carga precoz. Estudio preliminar. [Osteosynthesis of ankle fracture. Evolutionary analysis with early loading. Preliminary study].

    Directory of Open Access Journals (Sweden)

    Juan Manuel Yañez Arauz

    2016-05-01

    Full Text Available Introducción La reducción y osteosíntesis de las fracturas del tobillo, permiten una recuperación precoz. Sin embargo, clásicamente no se permite la carga del peso durante casi 6 semanas. El objetivo del presente estudio, es analizar si la carga inmediata del peso en fracturas de peroné, produce complicaciones y/o desplazamientos secundarios. Material y métodos Se analizaron 21 pacientes operados de fracturas 44AOB1, y se les dio carga inmediata. Se evaluó clínica y radiográficamente la evolución de los mismos. El seguimiento fue a más de 3 meses. Resultados La carga del peso con protección con bota “Walker”, fue ejecutada por los pacientes a los 2 días promedio. El puntaje AOFAS para tobillo evaluado a los 3 meses del post-operatorio fue de 99 puntos promedio. El retorno a la actividad laboral fue promedio 2,1 meses; y el retorno a la actividad deportiva previa, fue promedio de 2,95 meses. En la radiología del POP a más de 90 días de seguimiento, la reducción no sufrió desplazamientos secundarios. Discusión Aun existe controversia sobre el manejo postoperatorio en las fracturas de tobillo. Actualmente se sabe que el movimiento temprano luego de la fijación interna, es beneficioso para disminuir la enfermedad del yeso. La carga de peso temprana facilitaron la restauración de la amplitud de movimiento de la articulación lesionada, disminuyeron la hinchazón, la atrofia de los tejidos blandos, y previnieron el desarrollo de osteoporosis. Conclusiones Las fracturas tipo AO 44B1 de baja energía, tratados mediante reducción y osteosíntesis, pueden realizar carga de peso precoz, sin riesgo de desplazamientos secundarios. La carga precoz junto a la movilización temprana, presenta muy buena evolución clínica, y no incide en un mayor índice de complicaciones.

  11. The breast implant controversy.

    Science.gov (United States)

    Cook, R R; Harrison, M C; LeVier, R R

    1994-02-01

    The breast implant issue is a "bad news/good news" story. For many women with implants, the controversy has caused a fair degree of anxiety which may or may not be resolved as further information becomes available. It has also taken its toll on Dow Corning. Whole lines of medical products have been eliminated or are being phase out. The development of new medical applications has been terminated. As a consequence, employees have lost their jobs. What the effect will be on the biomedical industry as a whole remains to be seen (11). While silicones have been an important component in various medical devices, it is likely that other materials can be used as replacements. However, suppliers of non-silicone materials are also reevaluating their role in this market. For example, Du Pont, the nation's largest chemical company, has determined that the unpredictable and excessive costs of doing business with manufacturers of implantable medical devices no longer justifies the unrestricted sale of standard raw materials into this industry. Other companies are quietly following suit. On the up side, it is possible that the research being driven by this controversy will result in a greater understanding of the immunologic implications of xenobiotics, of the importance of nonbiased observations, of the need for ready access to valid data sets, and of the opportunity for valid scientific information to guide legal decisions. Only time will tell.

  12. Cochlear implants in children implanted in Jordan: A parental overview.

    Science.gov (United States)

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (pparents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  13. Implante de lente intraocular trifocal difractivo: análisis y resultado de la agudeza visual

    Directory of Open Access Journals (Sweden)

    Miguel Ángel Ibáñez-Hernández

    2017-09-01

    Conclusiones: El implante de un lente intraocular trifocal difractivo es capaz de proporcionar una excelente visión lejana, intermedia y cercana, con escasas aberraciones ópticas, permitiendo una mejor calidad visual útil en actividades desarrolladas a diferentes distancias.

  14. Sub-meninges implantation reduces immune response to neural implants.

    Science.gov (United States)

    Markwardt, Neil T; Stokol, Jodi; Rennaker, Robert L

    2013-04-15

    Glial scar formation around neural interfaces inhibits their ability to acquire usable signals from the surrounding neurons. To improve neural recording performance, the inflammatory response and glial scarring must be minimized. Previous work has indicated that meningeally derived cells participate in the immune response, and it is possible that the meninges may grow down around the shank of a neural implant, contributing to the formation of the glial scar. This study examines whether the glial scar can be reduced by placing a neural probe completely below the meninges. Rats were implanted with sets of loose microwire implants placed either completely below the meninges or implanted conventionally with the upper end penetrating the meninges, but not attached to the skull. Histological analysis was performed 4 weeks following surgical implantation to evaluate the glial scar. Our results found that sub-meninges implants showed an average reduction in reactive astrocyte activity of 63% compared to trans-meninges implants. Microglial activity was also reduced for sub-meninges implants. These results suggest that techniques that isolate implants from the meninges offer the potential to reduce the encapsulation response which should improve chronic recording quality and stability. Published by Elsevier B.V.

  15. con mala calidad de vida

    Directory of Open Access Journals (Sweden)

    Agustín Martín-Rodríguez

    2007-01-01

    Full Text Available En este estudio ex post facto se ha analizado si los familiares de pacientes con mala calidad de vida presentan diferencias en las variables clínicas de personalidad y relaciones familiares en función de que el paciente haya estado o no ingresado en una Unidad de Cuidados Intensivos. Seleccionamos dos grupos: 29 familiares de pacientes traumatizados graves transcurridos cuatro años de su ingreso en una UCI de Traumatología y con mala calidad de vida (debido a secuelas físicas y/o psicológicas tras el ingreso, tales como traumatismos craneoencefálicos, politraumatismos y tetraplejias traumáticas y 32 familiares de pacientes con mala calidad de vida con cuatro años de evolución de su enfermedad física (hipertensión, diabetes, artritis reumatoide y síndrome de intestino irritable que no han estado ingresados en la UCI. Para alcanzar nuestro objetivo empleamos una Encuesta Psicosocial y los siguientes instrumentos: Cuestionario de Análisis Clínico, Escala de Clima Social en la Familia y Escala de Adaptación Psicosocial de la Enfermedad. Los resultados mostraron que los familiares de pacientes con mala calidad de vida que estuvieron ingresados en la UCI hace cuatro años, presentan diferencias significativas en las variables agitación y expresividad comparados con los familiares de pacientes con mala calidad de vida que no han estado ingresados en la UCI.

  16. Improving osseointegration of dental implants.

    Science.gov (United States)

    Elias, Carlos Nelson; Meirelles, Luiz

    2010-03-01

    In the beginning of implantology, the procedures adopted for treating patients were performed in two surgical phases with an interval of 3-6 months. Nowadays, it is possible to insert and load a dental implant in the same surgical procedure. This change is due to several factors, such as improvement of surgical technique, modifications of the implant design, increased quality of implant manufacturing, development of the surgical instruments' quality, careful patient screening and adequate treatment of the implant surface. The clinical results show that adequate treatment of surfaces is crucial for reducing healing time and treating at-risk patients. The surface properties of dental implants can be significantly improved at the manufacturing stage, affecting cells' activity during the healing phase that will ultimately determine the host tissue response, a fundamental requirement for clinical success. This review focuses on different types of dental implant surfaces and the influence of surface characteristics on osseointegration.

  17. Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

    Directory of Open Access Journals (Sweden)

    Sung-Eun Kim

    2014-09-01

    Full Text Available BackgroundIn 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience.MethodsFrom November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction.ResultsThe mean breast resection volume was 240 mL (range, 83-540 mL. The mean size of the breast implants was 217 mL (range, 125-395 mL. Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen.ConclusionsBy using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

  18. Dental implants in growing children

    Directory of Open Access Journals (Sweden)

    S K Mishra

    2013-01-01

    Full Text Available The replacement of teeth by implants is usually restricted to patients with completed craniofacial growth. The aim of this literature review is to discuss the use of dental implants in normal growing patients and in patients with ectodermal dysplasia and the influence of maxillary and mandibular skeletal and dental growth on the stability of those implants. It is recommended that while deciding the optimal individual time point of implant insertion, the status of skeletal growth, the degree of hypodontia, and extension of related psychological stress should be taken into account, in addition to the status of existing dentition and dental compliance of a pediatric patient.

  19. Printing of Titanium implant prototype

    International Nuclear Information System (INIS)

    Wiria, Florencia Edith; Shyan, John Yong Ming; Lim, Poon Nian; Wen, Francis Goh Chung; Yeo, Jin Fei; Cao, Tong

    2010-01-01

    Dental implant plays an important role as a conduit of force and stress to flow from the tooth to the related bone. In the load sharing between an implant and its related bone, the amount of stress carried by each of them directly related to their stiffness or modulus. Hence, it is a crucial issue for the implant to have matching mechanical properties, in particular modulus, between the implant and its related bone. Titanium is a metallic material that has good biocompatibility and corrosion resistance. Whilst the modulus of the bulk material is still higher than that of bone, it is the lowest among all other commonly used metallic implant materials, such as stainless steel or cobalt alloy. Hence it is potential to further reduce the modulus of pure Titanium by engineering its processing method to obtain porous structure. In this project, porous Titanium implant prototype is fabricated using 3-dimensional printing. This technique allows the flexibility of design customization, which is beneficial for implant fabrication as tailoring of implant size and shape helps to ensure the implant would fit nicely to the patient. The fabricated Titanium prototype had a modulus of 4.8-13.2 GPa, which is in the range of natural bone modulus. The compressive strength achieved was between 167 to 455 MPa. Subsequent cell culture study indicated that the porous Titanium prototype had good biocompatibility and is suitable for bone cell attachment and proliferation.

  20. Cochlear implantation in Mondini dysplasia.

    Science.gov (United States)

    Daneshi, Ahmad; Hassanzadeh, Saeid; Abasalipour, Parvaneh; Emamdjomeh, Hessamaddin; Farhadi, Mohammad

    2003-01-01

    The use of cochlear implantation to treat patients with inner ear malformations such as Mondini dysplasia has been increasingly successful. Until now, conventional hearing aids in these patients have not performed well. Consequently, the hearing problem for patients with this condition has been somewhat improved with the use of cochlear implants. Various results of cochlear implantation have been reported in these patients so far. This is a report of 5 patients with Mondini malformation who have undergone cochlear implant surgery. Copyright 2003 S. Karger AG, Basel

  1. Implant-retained maxillary overdentures.

    Science.gov (United States)

    Eckert, Steven E; Carr, Alan B

    2004-07-01

    Overdentures supported by osseointegrated implants overcome many of the complications observed with overdentures supported by natural teeth. Dental implants are free of biologic consequences associated with natural teeth, such as dental caries and periodontal disease. Bone undercuts adjacent to implants do not mimic those found adjacent to natural tooth roots. Implants are used to provide predictable retention, support, and stability for overdenture prostheses. When lip or facial support is required, the overdenture is the treatment of choice. Likewise the overdenture may improve phonetic deficiencies associated with alveolar bone loss.

  2. Cochlear implants in Waardenburg syndrome.

    Science.gov (United States)

    Cullen, Robert D; Zdanski, Carlton; Roush, Patricia; Brown, Carolyn; Teagle, Holly; Pillsbury, Harold C; Buchman, Craig

    2006-07-01

    Waardenburg syndrome is an autosomal-dominant syndrome characterized by dystopia canthorum, hyperplasia of the eyebrows, heterochromia irides, a white forelock, and sensorineural hearing loss in 20% to 55% of patients. This patient population accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with Waardenburg syndrome who have undergone cochlear implantation. Pediatric cochlear implant recipients with documented evidence of Waardenburg syndrome underwent retrospective case review. All patients received their cochlear implants at the study institution followed by outpatient auditory habilitation. Charts were reviewed for etiology and duration of deafness, age at time of cochlear implantation, perioperative complications, duration of use, and performance outcomes. Results of standard tests batteries for speech perception and production administered as a part of the patients' auditory habilitation were reviewed. Seven patients with Waardenburg syndrome and cochlear implants were identified. The average age at implantation was 37 months (range, 18-64 months) and the average duration of use was 69 months (range, 12-143 months). All of these patients are active users of their devices and perform very well after implantation. There were no major complications in this small group of patients. Children with congenital sensorineural hearing loss without other comorbidities (e.g., developmental delay, inner ear malformations) perform well when they receive cochlear implantation and auditory habilitation. Patients with Waardenburg syndrome can be expected to have above-average performance after cochlear implantation.

  3. Enfermeras con licenciatura en México: estimación de los niveles de deserción escolar y desperdicio laboral

    Directory of Open Access Journals (Sweden)

    Nigenda Gustavo

    2006-01-01

    Full Text Available OBJETIVO: Estimar y analizar la tasa de desperdicio entre las personas con estudios de enfermería a nivel de licenciatura, durante el periodo de su formación y en el mercado de trabajo. MATERIAL Y MÉTODOS: El desperdicio escolar se trabajó a partir de los datos de la Asociación Nacional de Universidades e Instituciones de Educación Superior (ANUIES entre los años de 1978 y 2002. Para la estimación del desperdicio laboral, se utilizó la base de datos del XII Censo General de Población y Vivienda 2000. Para la valoración de ambos fenómenos se definieron conceptos y fórmulas. RESULTADOS: La tasa de desperdicio escolar (TDE para la generación que concluyó en el año 2002 se ubicó en 252 por cada 1 000, muy por debajo de la registrada en 1987, que fue de 555. En el mercado laboral, para el año 2000, del total de personas que estudiaron licenciatura en enfermería, 55.2% realizaba actividades remuneradas en el área que estudió; 15.4% trabajaba en actividades ajenas a su formación académica y 16.2% se dedicaba al hogar. La tasa global de desperdicio laboral (TGDL es de 410 por cada 1 000 personas que estudiaron licenciatura en enfermería. CONCLUSIONES: Existe un importante desperdicio de capacidades y habilidades entre la población con estudios de enfermería a nivel licenciatura, tanto en la formación como en el mercado laboral, que requiere de respuestas inmediatas por parte de las instituciones responsables.

  4. Beneficios económicos del implante coclear para la hipoacusia sensorineural profunda Economic benefits of the cochlear implant for treating profound sensorineural hearing loss

    Directory of Open Access Journals (Sweden)

    Augusto Peñaranda

    2012-04-01

    Full Text Available OBJETIVO: Evaluar el costo-beneficio (CB, costo-utilidad (CU y costo-efectividad (CE de la implantación coclear, comparándola con el uso de audífonos en niños con hipoacusia sensorineural profunda bilateral. MÉTODOS: Se empleó la técnica no paramétrica Propensity Score Matching (PSM para realizar la evaluación de impacto económico del implante y así llevar a cabo los análisis CB, CU y CE. Se utilizó información primaria, tomada aleatoriamente a 100 pacientes: 62 intervenidos quirúrgicamente con el implante coclear (grupo de tratamiento y 38 pertenecientes al grupo de control o usuarios de audífono para tratar la hipoacusia sensorineural profunda. RESULTADOS: Se halló un diferencial de costos económicos -en beneficio del implante coclear- cercano a US$ 204 000 entre el implante y el uso de audífonos durante la esperanza de vida de los pacientes analizados. Dicha cifra indica los mayores gastos que deben cubrir los pacientes con audífono. Con este valor descontado, el indicador costo-beneficio señala que por cada dólar invertido en el implante coclear, para tratar al paciente, el retorno de la inversión es US$ 2,07. CONCLUSIONES: El implante coclear genera beneficios económicos para el paciente. También produce utilidades en salud dado que se encontró una relación positiva de CU (ganancia en decibeles y CE (ganancia en discriminación del lenguaje.OBJECTIVE: Evaluate the cost-benefit, cost-utility, and cost-effectiveness of cochlear implantation, comparing it to the use of hearing aids in children with profound bilateral sensorineural hearing loss. METHODS: The nonparametric propensity score matching method was used to carry out an economic and impact assessment of the cochlear implant and then perform cost-benefit, cost-utility, and cost-effectiveness analyses. Primary information was used, taken randomly from 100 patients: 62 who received cochlear implants (treatment group and 38 belonging to the control group who used

  5. Age at implantation and auditory memory in cochlear implanted children.

    Science.gov (United States)

    Mikic, B; Miric, D; Nikolic-Mikic, M; Ostojic, S; Asanovic, M

    2014-05-01

    Early cochlear implantation, before the age of 3 years, provides the best outcome regarding listening, speech, cognition an memory due to maximal central nervous system plasticity. Intensive postoperative training improves not only auditory performance and language, but affects auditory memory as well. The aim of this study was to discover if the age at implantation affects auditory memory function in cochlear implanted children. A total of 50 cochlear implanted children aged 4 to 8 years were enrolled in this study: early implanted (1-3y) n = 27 and late implanted (4-6y) n = 23. Two types of memory tests were used: Immediate Verbal Memory Test and Forward and Backward Digit Span Test. Early implanted children performed better on both verbal and numeric tasks of auditory memory. The difference was statistically significant, especially on the complex tasks. Early cochlear implantation, before the age of 3 years, significantly improve auditory memory and contribute to better cognitive and education outcomes.

  6. con dietas suplementadas con Cromo-L-metionina

    Directory of Open Access Journals (Sweden)

    Ram\\u00F3n Garc\\u00EDa-Castillo

    2006-01-01

    Full Text Available Un total de 48 cerdos (Sus scrofa domesticus; 24 machos castrados y 24 hembras cruzados (Yorkshire, Hampshire, Duroc y Landrace de 3,5 a 4,0 meses de edad y 60,0 ± 5,0 kg PV en finalización. Se alimentaron con dietas isoproteícas (14,5 % PC e isoenergéticas (3.400 kcal EM/kg de MS, adicionadas con Cr-L-metionina (MiCroPlex® (0, 200, 400 y 600 ppb. El experimento tuvo una duración de 45 días y se realizó de agosto a noviembre del 2002 en las instalaciones de la Universidad Autónoma Agraria Antonio Narro, localizada en Saltillo, Coahuila, México. Al tener los animales aproximadamente 95 kg PV, se tomó muestra de 15 ml de sangre por cada animal para determinar la concentración de glucosa, ácido úrico, creatinina, urea, proteinas totales y colesterol. Se aplicó un diseño completamente al azar con arreglo factorial 2 x 4; dos para el factor sexo y cuatro para nivel de cromo. Los metabolitos en suero no fueron afectados (P>0,05 por el factor sexo. La glucosa en suero disminuyó (P<0,05 y el colesterol incrementó (P<0,05 con cromo en la dieta. Se concluye que el Cr incrementa el metabolismo de glucosa y disminuye el de colesterol, con lo cual puede haber energía disponible para síntesis de proteína la cual es necesaria para el crecimiento de los animales

  7. Cluster Implantation and Deposition Apparatus

    DEFF Research Database (Denmark)

    Hanif, Muhammad; Popok, Vladimir

    2015-01-01

    In the current report, a design and capabilities of a cluster implantation and deposition apparatus (CIDA) involving two different cluster sources are described. The clusters produced from gas precursors (Ar, N etc.) by PuCluS-2 can be used to study cluster ion implantation in order to develop...

  8. Porous metal for orthopedics implants

    OpenAIRE

    Matassi, Fabrizio; Botti, Alessandra; Sirleo, Luigi; Carulli, Christian; Innocenti, Massimo

    2013-01-01

    Porous metal has been introduced to obtain biological fixation and improve longevity of orthopedic implants. The new generation of porous metal has intriguing characteristics that allows bone healing and high osteointegration of the metallic implants. This article gives an overview about biomaterials properties of the contemporary class of highly porous metals and about the clinical use in orthopaedic surgery.

  9. [The impact of dental implants

    NARCIS (Netherlands)

    Meijer, G.J.

    2013-01-01

    The importance of the introduction of dental implants can only be understood when the historical context is clarified. In the past, the main treatment carried out by dentists consisted of filling or, in unfortunate cases, removal of painful teeth. Only since the introduction of dental implants did

  10. Sequential provisional implant prosthodontics therapy.

    Science.gov (United States)

    Zinner, Ira D; Markovits, Stanley; Jansen, Curtis E; Reid, Patrick E; Schnader, Yale E; Shapiro, Herbert J

    2012-01-01

    The fabrication and long-term use of first- and second-stage provisional implant prostheses is critical to create a favorable prognosis for function and esthetics of a fixed-implant supported prosthesis. The fixed metal and acrylic resin cemented first-stage prosthesis, as reviewed in Part I, is needed for prevention of adjacent and opposing tooth movement, pressure on the implant site as well as protection to avoid micromovement of the freshly placed implant body. The second-stage prosthesis, reviewed in Part II, should be used following implant uncovering and abutment installation. The patient wears this provisional prosthesis until maturation of the bone and healing of soft tissues. The second-stage provisional prosthesis is also a fail-safe mechanism for possible early implant failures and also can be used with late failures and/or for the necessity to repair the definitive prosthesis. In addition, the screw-retained provisional prosthesis is used if and when an implant requires removal or other implants are to be placed as in a sequential approach. The creation and use of both first- and second-stage provisional prostheses involve a restorative dentist, dental technician, surgeon, and patient to work as a team. If the dentist alone cannot do diagnosis and treatment planning, surgery, and laboratory techniques, he or she needs help by employing the expertise of a surgeon and a laboratory technician. This team approach is essential for optimum results.

  11. Piezosurgery in implant dentistry

    Directory of Open Access Journals (Sweden)

    Stübinger S

    2015-11-01

    Full Text Available Stefan Stübinger,1 Andres Stricker,2 Britt-Isabelle Berg3,4 1Hightech Research Center of Cranio-maxillofacial Surgery, University of Basel, Allschwil, Switzerland; 2Private Practice, Konstanz, Germany; 3Department of Cranio-maxillofacial Surgery, University Hospital Basel, Basel, Switzerland; 4Division of Oral and Maxillofacial Radiology, Columbia University Medical Center, New York, NY, USA Abstract: Piezosurgery, or the use of piezoelectric devices, is being applied increasingly in oral and maxillofacial surgery. The main advantages of this technique are precise and selective cuttings, the avoidance of thermal damage, and the preservation of soft-tissue structures. Through the application of piezoelectric surgery, implant-site preparation, bone grafting, sinus-floor elevation, edentulous ridge splitting or the lateralization of the inferior alveolar nerve are very technically feasible. This clinical overview gives a short summary of the current literature and outlines the advantages and disadvantages of piezoelectric bone surgery in implant dentistry. Overall, piezoelectric surgery is superior to other methods that utilize mechanical instruments. Handling of delicate or compromised hard- and soft-tissue conditions can be performed with less risk for the patient. With respect to current and future innovative surgical concepts, piezoelectric surgery offers a wide range of new possibilities to perform customized and minimally invasive osteotomies. Keywords: implantology, piezoelectric device, piezosurgery, maxillary sinus elevation, bone grafting, osteotomy, edentulous ridge splitting

  12. Labyrinthectomy with cochlear implantation.

    Science.gov (United States)

    Zwolan, T A; Shepard, N T; Niparko, J K

    1993-05-01

    Numerous reports indicate that the cochlea remains responsive to electrical stimulation following labyrinthectomy. We report a case of a 47-year-old woman with a severe to profound sensorineural hearing loss from birth, who developed episodic vertigo with symptoms suggestive of delayed onset endolymphatic hydrops. Following 8 months of failed medical and vestibular rehabilitation management, a right-sided labyrinthectomy combined with cochlear implantation was performed without complication. Postoperatively the patient was free of vertigo. Attempts to activate the patient's device between 4 to 12 weeks after surgery were unsuccessful as stimulation of the electrodes resulted in discomfort. However, all 20 electrodes elicited comfortable hearing sensations 16 weeks postsurgery. One year after the successful activation, the patient demonstrated improved sound awareness and speech recognition with the implant when compared with preoperative performance with a hearing aid. This case study suggests that electrical detection thresholds with prosthetic stimulation may be unstable in the recently labyrinthectomized ear but supports and extends prior observations of preserved cochlear responsiveness after labyrinthectomy.

  13. Recubrimiento de acero con polidopamina

    OpenAIRE

    Carrasco Rodríguez, Javier

    2013-01-01

    Se ha obtenido recubrimientos de polidopamina en acero mecánicamente resistentes y con tiempos de obtención relativamente pequeños a través de la polimerización de la dopamina bajo diferentes condiciones.

  14. Ion implantation and amorphous metals

    International Nuclear Information System (INIS)

    Hohmuth, K.; Rauschenbach, B.

    1981-01-01

    This review deals with ion implantation of metals in the high concentration range for preparing amorphous layers (>= 10 at%, implantation doses > 10 16 ions/cm 2 ). Different models are described concerning formation of amorphous phases of metals by ion implantation and experimental results are given. The study of amorphous phases has been carried out by the aid of Rutherford backscattering combined with the channeling technique and using transmission electron microscopy. The structure of amorphous metals prepared by ion implantation has been discussed. It was concluded that amorphous metal-metalloid compounds can be described by a dense-random-packing structure with a great portion of metal atoms. Ion implantation has been compared with other techniques for preparing amorphous metals and the adventages have been outlined

  15. Ion implantation: an annotated bibliography

    International Nuclear Information System (INIS)

    Ting, R.N.; Subramanyam, K.

    1975-10-01

    Ion implantation is a technique for introducing controlled amounts of dopants into target substrates, and has been successfully used for the manufacture of silicon semiconductor devices. Ion implantation is superior to other methods of doping such as thermal diffusion and epitaxy, in view of its advantages such as high degree of control, flexibility, and amenability to automation. This annotated bibliography of 416 references consists of journal articles, books, and conference papers in English and foreign languages published during 1973-74, on all aspects of ion implantation including range distribution and concentration profile, channeling, radiation damage and annealing, compound semiconductors, structural and electrical characterization, applications, equipment and ion sources. Earlier bibliographies on ion implantation, and national and international conferences in which papers on ion implantation were presented have also been listed separately

  16. Pansinusitis y afectación intracraneal por implante dental Pansinusitis and intracranial impact of a dental implant

    Directory of Open Access Journals (Sweden)

    Josep Rubio-Palau

    2012-03-01

    Full Text Available Las sinusitis odontógenas son una patología relativamente frecuente causada por infecciones dentales, quistes periapicales así como tras procedimientos bucodentales como una endodoncia, una elevación sinusal o la colocación de un implante. A continuación se presenta un caso extremo de una pansinusitis derecha con fistulización a espacio epidural causada por un implante osteointegrado. Ante la sospecha de una sinusitis maxilar de origen odontogénico se debe iniciar rápidamente un tratamiento antibiótico correcto y un seguimiento estrecho ya que pueden tener consecuencias fatales como la pérdida de un ojo, abscesos cerebrales o incluso la muerte.Odontogenic sinusitis is a relatively common disease caused by dental infections, periapical cysts and oral procedures such as root canal, sinus lift or implant placement. We report an extreme case of a right pansinusitis with an epidural space fistula caused by osseointegrated implants. When maxillary sinusitis of odontogenic origin is suspected, we should quickly start effective antibiotic treatment and monitor the patient closely because odontogenic sinusitis can have serious consequences, such as the loss of an eye, brain abscess or death.

  17. Tratamiento del maxilar posterior atrófico mediante técnica de reconstrucción tridimensional con elevación de seno y abordaje «en tunel»

    Directory of Open Access Journals (Sweden)

    Andrés Restoy

    2015-01-01

    Conclusiones: El tratamiento del sector posterior maxilar atrófico mediante reconstrucción tridimensional con autoinjerto óseo, elevación sinusal y abordaje por tunelización es una técnica que proporciona resultados predecibles y estables, permitiendo la rehabilitación con coronas sobre implantes dentales de dimensiones adecuadas.

  18. Tribological properties of nitrogen implanted and boron implanted steels

    International Nuclear Information System (INIS)

    Kern, K.T.

    1996-01-01

    Samples of a steel with high chrome content was implanted separately with 75 keV nitrogen ions and with 75 keV boron ions. Implanted doses of each ion species were 2-, 4-, and 8 x 10 17 /cm 2 . Retained doses were measured using resonant non-Rutherford Backscattering Spectrometry. Tribological properties were determined using a pin-on-disk test with a 6-mm diameter ruby pin with a velocity of 0.94 m/min. Testing was done at 10% humidity with a load of 377 g. Wear rate and coefficient of friction were determined from these tests. While reduction in the wear rate for nitrogen implanted materials was observed, greater reduction (more than an order of magnitude) was observed for boron implanted materials. In addition, reduction in the coefficient of friction for high-dose boron implanted materials was observed. Nano-indentation revealed a hardened layer near the surface of the material. Results from grazing incidence x-ray diffraction suggest the formation of Fe 2 N and Fe 3 N in the nitrogen implanted materials and Fe 3 B in the boron implanted materials. Results from transmission electron microscopy will be presented

  19. Cochlear implantation in late-implanted adults with prelingual deafness.

    Science.gov (United States)

    Most, Tova; Shrem, Hadas; Duvdevani, Ilana

    2010-01-01

    The purpose of this study was to examine the effect of cochlear implantation (CI) on prelingually deafened participants who were implanted as adults. The effect of the CI was examined with regard to the following variables: communication, family, social skills, education, and work satisfaction with one's life, loneliness, and self-esteem. Thirty-eight adults participated. Four self-report questionnaires were used at 2 points in time: before and after CI. The research findings show significant differences in the reports of most variables before and after implantation. The participants felt better with regard to communication, social skills, education, and work and satisfaction with one's life after implantation in comparison to their feelings before implantation. Furthermore, they felt less lonely after implantation. However, there were no significant differences before and after implantation regarding their feelings within the family and regarding their self-esteem. The results demonstrated the need to evaluate the benefits resulting from the CI not only with traditional clinical measures but with additional measures as well. Furthermore, they demonstrated the benefit of the CI on the positive psychosociological implications of prelingually deafened adults. Copyright © 2010 Elsevier Inc. All rights reserved.

  20. A Retrospective Analysis of Ruptured Breast Implants

    Directory of Open Access Journals (Sweden)

    Woo Yeol Baek

    2014-11-01

    Full Text Available BackgroundRupture is an important complication of breast implants. Before cohesive gel silicone implants, rupture rates of both saline and silicone breast implants were over 10%. Through an analysis of ruptured implants, we can determine the various factors related to ruptured implants.MethodsWe performed a retrospective review of 72 implants that were removed for implant rupture between 2005 and 2014 at a single institution. The following data were collected: type of implants (saline or silicone, duration of implantation, type of implant shell, degree of capsular contracture, associated symptoms, cause of rupture, diagnostic tools, and management.ResultsForty-five Saline implants and 27 silicone implants were used. Rupture was diagnosed at a mean of 5.6 and 12 years after insertion of saline and silicone implants, respectively. There was no association between shell type and risk of rupture. Spontaneous was the most common reason for the rupture. Rupture management was implant change (39 case, microfat graft (2 case, removal only (14 case, and follow-up loss (17 case.ConclusionsSaline implants have a shorter average duration of rupture, but diagnosis is easier and safer, leading to fewer complications. Previous-generation silicone implants required frequent follow-up observation, and it is recommended that they be changed to a cohesive gel implant before hidden rupture occurs.

  1. Inseminación artificial a tiempo fijo en vacas con proestro prolongado de 60 y 72 horas

    Directory of Open Access Journals (Sweden)

    Darwin Omar Yánez-Avalos

    2018-05-01

    Full Text Available La inseminación artificial a tiempo fijo (IATF en ganado bovino ha permitido el uso de toros genéticamente superiores para maximizar la calidad de los terneros producidos. Sin embargo, la implementación de esta técnica reproductiva dificulta su aplicación en hembras bovinas que están con cría al pie durante varios meses de lactancia. Una solución inmediata a la disminución de la fertilidad en vacas incluye la utilización de hormonas. Se ha desarrollado una serie de tratamientos hormonales que es capaz de controlar el momento de la primera inseminación artificial (IA y las inseminaciones posteriores en vacas no preñadas y para el tratamiento de vacas en anestro. El objetivo de este trabajo fue evaluar dos protocolos con proestro prolongado con inseminación artificial a tiempo fijo (IATF a las 60 o 72 horas, en vacas doble propósito de la Amazonía Ecuatoriana. El trabajo se realizó desde octubre de 2015 a octubre de 2016. Se inseminaron 226 vacas multíparas cruzas Pardo Suizo con cría al pie, a las 60 (T1, n=115 y 72 (T2, n= 111 horas de retirado el dispositivo con progesterona (0,5g. La tasa de concepción para T1 fue del 61% (70/115 y para T2: el 47% de preñez (52/111, con diferencias significativas (p≤0,05. El celo en promedio fue de 70,8%, sin diferencia significativa entre tratamientos (P=3,15; p≥0,082, para T1 fue del 76% y para T2 del 65%. El crecimiento folicular al retiro del dispositivo con progesterona (T1: 9,53±0,11 mm; T2: 9,87± 0,12 mm, la IATF (T1: 12,3±0,12 mm; T2: 11,9±0,12 mm y el tamaño del cuerpo lúteo (T1: 23,1±0,14 mm; T2: 22,8± 0,15 mm, no mostraron diferencias significativas entre ambos protocolos (p≥0,05. Ambos tratamientos no mostraron diferencias significativas para el desarrollo folicular al momento del retiro del dispositivo de IATF y en el tamaño del cuerpo lúteo medido al día siete posterior a la misma. La tasa de preñez fue superior para el protocolo de 60 horas.

  2. [Maintenance care for dental implant].

    Science.gov (United States)

    Kamoi, K

    1989-10-01

    Dental implant has tried at the early stage in 19th century recovering an oral function and esthetics. Technological revolutions in biochemical and new materials have developed on the remarkable change in the dental implants, nowadays we call the three generation therapy for dental implantology. There are many kinds of methods and techniques in dental implants, however a lot of troublesome complication on the process of surgical phase, construction of prothodontics and prognosis of maintenance care. In the proceedings of this symposium, I would like to propose you how to manage the maintenance care for various kind of dental implants through the methodology and case presentations. Tendenay and future for dental implants The current outlook of dental implant has increasing supply and demand not only dentists but also patients. According to Japanese Welfare Ministry's report in 1987, average missing teeth over sixty years old generations are approximately 42% in accordance with NIDR (U.S.A.) research. They are missed on ten over teeth in full 28th teeth dentitions owing to dental caries and periodontal diseases. Generally speaking, latent implant patients are occupied on the same possibility of needs for dental implants both Japan and U.S.A. Management of maintenance care The patients hardly recognized the importance of plaque control for the maintenance care in the intraoral condition after implantation. Dentists and dental staffs must be instruct patients for importance of plaque removal and control, because they already had forgotten the habit of teeth cleaning, especially in the edenturous conditions. 1) Concept of establishment in oral hygiene. Motivation and instruction for patients include very important factors in dental implants as well as in periodontal diseases. Patients who could not achieve on good oral hygiene levels obtained no good results in the long term observations. To establish good oral hygiene are how to control supra plaque surrounding tissues

  3. Santiago, una ciudad con temor

    Directory of Open Access Journals (Sweden)

    Enrique Oviedo S.

    1999-04-01

    Full Text Available El objetivo general de este artículo es evaluar los efectos de la inseguridad ciudadana en el uso del espacio público. Dicha evaluación exige analizar dos relaciones que se establecen en el ámbito de la violencia: la relación entre victimización y percepción de inseguridad; y la que se establece entre actitudes sociales y resolución pacífica de conflictos nacionales. Para ello, se analizaron las variables victimización, percepción de inseguridad, uso del espacio físico, actitudes hacia el sistema institucional político y social y hacia la resolución de conflictos nacionales, y las posibles relaciones entre ellas. Los datos para realizar el estudio se obtuvieron por medio de una encuesta que se llevó a cabo con 1 200 personas de 18 y 70 años de edad residentes en la ciudad de Santiago. Los resultados indican que Santiago es una ciudad de habitantes con temor y que el aumento de la percepción de inseguridad de sus habitantes contrasta con el hecho de que las tasas de victimización se hayan mantenido, más o menos, constantes en los años que precedieron a la encuesta. El temor se relaciona con el abandono del espacio público físico y sociopolítico, así como con el refugio en los espacios y la vida privados. La actitud de resolver los conflictos por medios no pacíficos es frecuente y se asocia en mayor medida con la inseguridad, la actitud negativa hacia la democracia y la falta de expectativas sobre el futuro del país. Los resultados de este estudio respaldan la idea de que para superar el temor la gente tiende a adaptarse a la realidad adoptando una postura conformista, homogeneizando las creencias y los comportamientos, y sobreestimando la fuerza como medio para resolver las diferencias.

  4. Santiago, una ciudad con temor

    Directory of Open Access Journals (Sweden)

    Oviedo S. Enrique

    1999-01-01

    Full Text Available El objetivo general de este artículo es evaluar los efectos de la inseguridad ciudadana en el uso del espacio público. Dicha evaluación exige analizar dos relaciones que se establecen en el ámbito de la violencia: la relación entre victimización y percepción de inseguridad; y la que se establece entre actitudes sociales y resolución pacífica de conflictos nacionales. Para ello, se analizaron las variables victimización, percepción de inseguridad, uso del espacio físico, actitudes hacia el sistema institucional político y social y hacia la resolución de conflictos nacionales, y las posibles relaciones entre ellas. Los datos para realizar el estudio se obtuvieron por medio de una encuesta que se llevó a cabo con 1 200 personas de 18 y 70 años de edad residentes en la ciudad de Santiago. Los resultados indican que Santiago es una ciudad de habitantes con temor y que el aumento de la percepción de inseguridad de sus habitantes contrasta con el hecho de que las tasas de victimización se hayan mantenido, más o menos, constantes en los años que precedieron a la encuesta. El temor se relaciona con el abandono del espacio público físico y sociopolítico, así como con el refugio en los espacios y la vida privados. La actitud de resolver los conflictos por medios no pacíficos es frecuente y se asocia en mayor medida con la inseguridad, la actitud negativa hacia la democracia y la falta de expectativas sobre el futuro del país. Los resultados de este estudio respaldan la idea de que para superar el temor la gente tiende a adaptarse a la realidad adoptando una postura conformista, homogeneizando las creencias y los comportamientos, y sobreestimando la fuerza como medio para resolver las diferencias.

  5. Ion implantation apparatus

    International Nuclear Information System (INIS)

    Forneris, J.L.; Hicks, W.W.; Keller, J.H.; McKenna, C.M.; Siermarco, J.A.; Mueller, W.F.

    1981-01-01

    The invention relates to ion bombardment or implantation apparatus. It comprises an apparatus for bombarding a target with a beam of ions, including an arrangement for measuring the ion beam current and controlling the surface potential of the target. This comprises a Faraday cage formed, at least in part, by the target and by walls adjacent to, and electrically insulated from, the target and surrounding the beam. There is at least one electron source for supplying electrons to the interior of the Faraday cage and means within the cage for blocking direct rectilinear radiation from the source to the target. The target current is measured and combined with the wall currents to provide a measurement of the ion beam current. The quantity of electrons supplied to the interior of the cage can be varied to control the target current and thereby the target surface potential. (U.K.)

  6. Implantable biochemical fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Richter, G; Rao, J R

    1978-01-05

    Implantable biochemical fuel cells for the operation of heart pacemakers or artificial hearts convert oxidisable body substances such as glucose on the anode side and reduce the oxygen contained in body fluids at the cathode. The anode and cathode are separated by membranes which are impermeable to albumen and blood corpuscles in body fluids. A chemical shortcircuit cannot occur in practice if, according to the invention, one or more selective oxygen electrodes with carbon as catalyst are arranged so that the mixture which diffuses into the cell from body fluids during operation reaches the fuel cell electrode through the porous oxygen electrode. The membranes used must be permeable to water. Cellulose, polymerised polyvinyl alcohol or an ion exchanger with a buffering capacity between pH5 and 8 act as permeable materials.

  7. Implant materials modified by colloids

    Directory of Open Access Journals (Sweden)

    Zboromirska-Wnukiewicz Beata

    2016-03-01

    Full Text Available Recent advances in general medicine led to the development of biomaterials. Implant material should be characterized by a high biocompatibility to the tissue and appropriate functionality, i.e. to have high mechanical and electrical strength and be stable in an electrolyte environment – these are the most important properties of bioceramic materials. Considerations of biomaterials design embrace also electrical properties occurring on the implant-body fluid interface and consequently the electrokinetic potential, which can be altered by modifying the surface of the implant. In this work, the surface of the implants was modified to decrease the risk of infection by using metal colloids. Nanocolloids were obtained using different chemical and electrical methods. It was found that the colloids obtained by physical and electrical methods are more stable than colloids obtained by chemical route. In this work the surface of modified corundum implants was investigated. The implant modified by nanosilver, obtained by electrical method was selected. The in vivo research on animals was carried out. Clinical observations showed that the implants with modified surface could be applied to wounds caused by atherosclerotic skeleton, for curing the chronic and bacterial inflammations as well as for skeletal reconstruction surgery.

  8. Hematoma epidural lombar pós-cirurgico em paciente com leucemia: relato de caso Hematoma epidural lumbar posquirúrgico en paciente con leucemia: relato de caso Postoperative lumbar epidural hematoma in a patient with leukemia: case report

    Directory of Open Access Journals (Sweden)

    Wagner Pasqualini

    2012-09-01

    Full Text Available A ocorrência de hematoma epidural como complicação pós-cirúrgica é relativamente baixa. O reconhecimento dessa patologia no diagnóstico diferencial nas paraplegias pós-cirúrgicas imediatas e o tratamento precoce por meio de intervenção cirúrgica com a descompressão do canal são fatores que estão diretamente relacionados à melhora do quadro neurológico. Este relato de caso é de um hematoma epidural no pós-operatório imediato de descompressão por estenose do canal vertebral lombar em paciente com leucemia.La ocurrencia de hematoma epidural, como complicación posquirúrgica, es relativamente baja. El reconocimiento de esa patología, en el diagnóstico diferencial en las paraplejías posquirúrgicas inmediatas y el tratamiento precoz por medio de intervención quirúrgica con la descompresión del canal, son factores que se relacionan directamente con la mejoría del cuadro neurológico. Este relato de caso es de un hematoma epidural en el posoperatorio inmediato, después de descompresión, por estenosis, del canal vertebral lumbar en paciente con leucemia.The occurrence of epidural hematoma as a postoperative complication is relatively low. The recognition of this condition in the differential diagnosis in the immediate postoperative paraplegia and the early surgical decompression are directly related with neurological improvement. We report a case of epidural hematoma in the early postoperative period of surgical decompression of the lumbar spinal canal, in a patient with leukemia.

  9. Basic research on maxillofacial implants

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, Yoshiro [Showa Univ., Tokyo (Japan). School of Dentistry

    2001-11-01

    Osseointegrated implants have begun to be used not only in general practice in dentistry but also in various clinical situations in the maxillofacial region. The process has yielded three problems: the spread of application, new materials and diagnostic methods, and management for difficult situations. This paper presents basic data and clinical guidelines for new applications, it investigates the characteristics of the materials and the usefulness of a new diagnostic method, and it studies effective techniques for difficult cases. The results obtained are as follows: Investigations into the spreading application. The lateral and superior orbital rim have sufficient bone thickness and width for the implant body to be placed. Osseointegrated implants, especially by the fixed bridge technique, are not recommended in the craniofacial bone and jaws of young children. Implant placement into bone after/before irradiation must be performed in consideration of impaired osteogenesis, the decrease of trabecular bone, and the time interval between implantation and irradiation. Investigations into materials and diagnostic methods. Hydroxyapatite-coated and titanium implants should be selected according to the characteristics of the materials. A dental simulating soft may also be applicable in the craniofacial region. Investigations into the management of difficult cases. Hyperbaric oxygen therapy (HBO), bone morphogenetic protein (BMP), and tissue engineering should be useful for improving the quality and increasing the quantity of bone where implants are placed. Soft tissue around implants placed in the reconstructed area should be replaced with mucosal tissue. The data obtained here should be useful for increasing the efficiency of osseointegrated implants, but further basic research is required in the future. (author)

  10. Basic research on maxillofacial implants

    International Nuclear Information System (INIS)

    Matsui, Yoshiro

    2001-01-01

    Osseointegrated implants have begun to be used not only in general practice in dentistry but also in various clinical situations in the maxillofacial region. The process has yielded three problems: the spread of application, new materials and diagnostic methods, and management for difficult situations. This paper presents basic data and clinical guidelines for new applications, it investigates the characteristics of the materials and the usefulness of a new diagnostic method, and it studies effective techniques for difficult cases. The results obtained are as follows: Investigations into the spreading application. The lateral and superior orbital rim have sufficient bone thickness and width for the implant body to be placed. Osseointegrated implants, especially by the fixed bridge technique, are not recommended in the craniofacial bone and jaws of young children. Implant placement into bone after/before irradiation must be performed in consideration of impaired osteogenesis, the decrease of trabecular bone, and the time interval between implantation and irradiation. Investigations into materials and diagnostic methods. Hydroxyapatite-coated and titanium implants should be selected according to the characteristics of the materials. A dental simulating soft may also be applicable in the craniofacial region. Investigations into the management of difficult cases. Hyperbaric oxygen therapy (HBO), bone morphogenetic protein (BMP), and tissue engineering should be useful for improving the quality and increasing the quantity of bone where implants are placed. Soft tissue around implants placed in the reconstructed area should be replaced with mucosal tissue. The data obtained here should be useful for increasing the efficiency of osseointegrated implants, but further basic research is required in the future. (author)

  11. Surface modifications of dental implants.

    Science.gov (United States)

    Stanford, C M

    2008-06-01

    Dental implant surface technologies have been evolving rapidly to enhance a more rapid bone formation on their surface and hold a potential to increase the predictability of expedited implant therapy. While implant outcomes have become highly predictable, there are sites and conditions that result in elevated implant loss. This paper reviews the impact of macro-retentive features which includes approaches to surface oxide modification, thread design, press-fit and sintered-bead technologies to increase predictability of outcomes. Implant designs that lead to controlled lateral compression of the bone can improve primary stability as long as the stress does not exceed the localized yield strength of the cortical bone. Some implant designs have reduced crestal bone loss by use of multiple cutting threads that are closely spaced, smoothed on the tip but designed to create a hoop-stress stability of the implant as it is completely seated in the osteotomy. Following the placement of the implant, there is a predictable sequence of bone turnover and replacement at the interface that allows the newly formed bone to adapt to microscopic roughness on the implant surface, and on some surfaces, a nanotopography (<10(-9) m scale) that has been shown to preferably influence the formation of bone. Newly emerging studies show that bone cells are exquisitely sensitive to these topographical features and will upregulate the expression of bone related genes for new bone formation when grown on these surfaces. We live in an exciting time of rapid changes in the modalities we can offer patients for tooth replacement therapy. Given this, it is our responsibility to be critical when claims are made, incorporate into our practice what is proven and worthwhile, and to continue to support and provide the best patient care possible.

  12. COCHLEAR IMPLANTATION PREVALENCE IN ELDERLY

    Directory of Open Access Journals (Sweden)

    A. V. Starokha

    2014-01-01

    Full Text Available Current paper describes an experience of cochlear implantation in elderly. Cochlear implantation has become a widely accepted intervention in the treatment of individuals with severe-to-profound sensorineural hearing loss. Cochlear implants are now accepted as a standard of care to optimize hearing and subsequent speech development in children and adults with deafness. But cochlear implantation affects not only hearing abilities, speech perception and speech production; it also has an outstanding impact on the social life, activities and self-esteem of each patient. The aim of this study was to evaluate the cochlear implantation efficacy in elderly with severe to profound sensorineural hearing loss. There were 5 patients under our observation. Surgery was performed according to traditional posterior tympanotomy and cochleostomy for cochlear implant electrode insertion for all observed patients. The study was conducted in two stages: before speech processor’s activation and 3 months later. Pure tone free field audiometry was performed to each patient to assess the efficiency of cochlear implantation in dynamics. The aim of the study was also to evaluate quality of life in elderly with severe to profound sensorineural hearing loss after unilateral cochlear implantation. Each patient underwent questioning with 36 Item Short Form Health Survey (SF-36. SF-36 is a set of generic, coherent, and easily administered quality-of-life measures. The SF-36 consists of eight scaled scores, which are the weighted sums of the questions in their section. Each scale is directly transformed into a 0-100 scale on the assumption that each question carries equal weight. The eight sections are: physical functioning; physical role functioning; emotional role functioning; vitality; emotional well-being; social role functioning; bodily pain; general health perceptions. Our results demonstrate that cochlear implantation in elderly consistently improved quality of life

  13. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    OBJECTIVES: The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. MATERIAL AND METHODS: A MEDLINE (PubMed), Embase and Cochrane library search...... of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment...... loss around implants with a scalloped implant-abutment connection. CONCLUSIONS: A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must...

  14. Implantable cardioverter defibrillator implantation in children in The Netherlands

    NARCIS (Netherlands)

    Ten Harkel, ADJ; Blom, NA; Reimer, AG; Tukkie, R; Sreeram, N; Bink-Boelkens, MTE

    To evaluate the indications, underlying cardiac disorders, efficacy and complications involved with implantable cardioverter-defibrillators (ICDs) in paediatric patients in The Netherlands, the records of all patients aged 18 years or younger who underwent ICD placement were reviewed

  15. Implantable cardioverter defibrillator implantation in children in The Netherlands

    NARCIS (Netherlands)

    ten Harkel, A. Derk Jan; Blom, Nico A.; Reimer, Annette G.; Tukkie, Raymond; Sreeram, Narayanswami; Bink-Boelkens, Margreet T. E.

    2005-01-01

    To evaluate the indications, underlying cardiac disorders, efficacy and complications involved with implantable cardioverter-defibrillators (ICDs) in paediatric patients in The Netherlands, the records of all patients aged 18 years or younger who underwent ICD placement were reviewed

  16. Nitrogen implantation in steel with an impulsive ion implanter

    International Nuclear Information System (INIS)

    Feugeas, J.N.; Gonzalez, C.O.; Hermida, J.; Nieto, M.; Peyronel, M.F.; Sanchez, G.

    1990-01-01

    This work describes the results of steel implantation with nitrogen, with a pulsed accelerator which provides a continuous ion energy spectrum giving a uniform profile of nitrogen without changing its operative conditions. (Author)

  17. Ion implantation in semiconductor bodies

    International Nuclear Information System (INIS)

    Badawi, M.H.

    1984-01-01

    Ions are selectively implanted into layers of a semiconductor substrate of, for example, semi-insulating gallium arsenide via a photoresist implantation mask and a metallic layer of, for example, titanium disposed between the substrate surface and the photoresist mask. After implantation the mask and metallic layer are removed and the substrate heat treated for annealing purposes. The metallic layer acts as a buffer layer and prevents possible contamination of the substrate surface, by photoresist residues, at the annealing stage. Such contamination would adversely affect the electrical properties of the substrate surface, particularly gallium arsenide substrates. (author)

  18. Hardness of ion implanted ceramics

    International Nuclear Information System (INIS)

    Oliver, W.C.; McHargue, C.J.; Farlow, G.C.; White, C.W.

    1985-01-01

    It has been established that the wear behavior of ceramic materials can be modified through ion implantation. Studies have been done to characterize the effect of implantation on the structure and composition of ceramic surfaces. To understand how these changes affect the wear properties of the ceramic, other mechanical properties must be measured. To accomplish this, a commercially available ultra low load hardness tester has been used to characterize Al 2 O 3 with different implanted species and doses. The hardness of the base material is compared with the highly damaged crystalline state as well as the amorphous material

  19. Do textured breast implants decrease the rate of capsular contracture compared to smooth implants?

    Directory of Open Access Journals (Sweden)

    Ignacio Cifuentes

    2017-08-01

    Full Text Available Resumen El uso de implantes mamarios con propósitos estéticos y reconstructivos se ha convertido en uno de los procedimientos más comunes realizados por los cirujanos plásticos. Existen diversos modelos de implantes mamarios, los cuales difieren en su tamaño, relleno, forma y característica de la envoltura, pudiendo ser lisa o texturizada. La contractura capsular es una de las principales complicaciones del uso de implantes mamarios y se ha planteado que las prótesis texturizadas podrían disminuir la incidencia de contractura capsular. Para responder esta pregunta utilizamos Epistemonikos, la mayor base de datos de revisiones sistemáticas en salud a nivel mundial, la cual es mantenida mediante búsquedas en múltiples fuentes de información, incluyendo MEDLINE, EMBASE, Cochrane, entre otras. Identificamos cinco revisiones sistemáticas que en conjunto incluyen 15 estudios primarios, 13 de ellos correspondientes a ensayos aleatorizados pertinentes a la pregunta de interés. Extrajimos los datos desde las revisiones identificadas, reanalizamos los datos de los estudios primarios, realizamos un metanálisis y preparamos tablas de resumen de los resultados utilizando el método GRADE. Concluimos que el uso de prótesis mamaria texturizada probablemente disminuye el riesgo de contractura capsular, sin embargo, podría asociarse a un aumento en el riesgo de linfoma anaplásico de células grandes.

  20. An introduction to single implant abutments.

    LENUS (Irish Health Repository)

    Warreth, Abdulhadi

    2013-01-01

    This article is an introduction to single implant abutments and aims to provide basic information about abutments which are essential for all dental personnel who are involved in dental implantology. Clinical Relevance: This article provides a basic knowledge of implants and implant abutments which are of paramount importance, as replacement of missing teeth with oral implants has become a well-established clinical procedure.

  1. Cochlear implantation in a bilateral Mondini dysplasia.

    Science.gov (United States)

    Turrini, M; Orzan, E; Gabana, M; Genovese, E; Arslan, E; Fisch, U

    1997-01-01

    We report the speech perception progress and programming procedures of a case of congenital profound deafness and bilateral Mondini dysplasia implanted with a Nucleus 20 + 2 cochlear implant at the age of six. Unclear relations between electrodes array and cochlear partition made implant programming difficult and non-standard procedures were set. Cochlear implantation may give excellent rehabilitative results also in cochleae with malformation.

  2. pacientes con insuficiencia renal terminal

    Directory of Open Access Journals (Sweden)

    Karen Herrera Herrera

    2011-01-01

    Full Text Available La presente investigación fundamenta en la clínica psicoanalítica el estudio de dos casos de tres personas diagnosticadas con IRT que reciben tratamiento de hemodiálisis, en razón a que dadas las características y el aumento de los reportes que se presentan, ya esto se considera un problema de salud pública. El objetivo principal es describir las características dinámicas del proceso de duelo en pacientes con IRT en un centro de terapia renal de la ciudad de Cartagena. El procedimiento metodológico empleó un diseño de tipo cualitativo; la investigación se desarrolló con un diseño clínico mediante el estudio de casos, y fundamentada en la hermenéutica psicoanalítica. Todo esto respaldado en la historia clínica, la entrevista semiestructurada individual y familiar, los test proyectivos, test del dibujo de la figura humana Machover y TAT de Murray, para la debida integración de los análisis. Se concluye que predominan funciones fallidas de los progenitores y que son individuos provenientes de familias psicosomáticas, que utilizan la enfermedad para obtener un beneficio secundario.

  3. con bajo peso al nacer

    Directory of Open Access Journals (Sweden)

    Adriana Mora Antó

    2005-01-01

    Full Text Available Esta investigación dio cuenta de la relación entre el estilo de funcionamiento familiar, los patrones de crianza y las edades de desarrollo evolutivo en niños, nacidos con bajo peso. El estudio descriptivo correlacional se realizó con 41 niños y sus madres, aplicándose cuestionarios sobre funcionamiento familiar, prácticas de crianza y desarrollo infantil. Los resultados señalaron la existencia de un funcionamiento familiar caracterizado por una cohesión amalgamada y una adaptabilidad caótica, una disciplina complaciente, falta de control y de límites claros en la díada madre-hijo. Se trataba de familias monoparentales, donde la temprana edad de concepción, el madresolterismo y el apoyo de la familia extensa eran constantes. Las edades evolutivas registradas indicaron un desarrollo inferior a la edad cronológica, en la mayor parte de los casos; sin embargo, éstas tendieron a ser superiores al compararlas con la edades reales de los infantes. No se encontró una correlación estadísticamente significativa entre la edad de desarrollo y los diferentes factores del funcionamiento familiar para algunos de los rangos de edad considerados; sin embargo, no se lo descartó por completo, especialmente en lo referente al optimismo familiar

  4. Implant retention systems for implant-retained overdentures.

    Science.gov (United States)

    Laverty, D P; Green, D; Marrison, D; Addy, L; Thomas, M B M

    2017-03-10

    Implant retained overdentures are being increasingly utilised in both general and specialist practice to rehabilitate patients with missing teeth, particularly those that are edentate. This article aims to inform the reader of a variety of retention systems that are available to retain an implant overdenture and to understand how these systems work, their advantages and disadvantages and to outline some of the clinical and treatment planning considerations involved in selecting the most appropriate retention system for patients.

  5. Implant Materials Generate Different Peri-implant Inflammatory Factors

    OpenAIRE

    Olivares-Navarrete, Rene; Hyzy, Sharon L.; Slosar, Paul J.; Schneider, Jennifer M.; Schwartz, Zvi; Boyan, Barbara D.

    2015-01-01

    Study Design. An in vitro study examining factors produced by human mesenchymal stem cells on spine implant materials. Objective. The aim of this study was to examine whether the inflammatory microenvironment generated by cells on titanium-aluminum-vanadium (Ti-alloy, TiAlV) surfaces is affected by surface microtexture and whether it differs from that generated on poly-ether-ether-ketone (PEEK). Summary of Background Data. Histologically, implants fabricated from PEEK have a fibrous connectiv...

  6. Mamoplastia de aumento dinámica con control de vectores

    Directory of Open Access Journals (Sweden)

    R.A. Vallarta-Rodríguez

    2014-12-01

    Full Text Available La mamoplastia de aumento debe ser una cirugía segura, predecible, duradera, que mantenga la forma natural de las mamas, preserve la sensibilidad del complejo areola-pezón, no altere la lactancia, con mínima reacción al implante colocado, y que no interfiera con los estudios imagenológicos. Cuando las mamas presentan alguna deformidad asociada tipo ptosis, mamas tuberosas, etc, el emplear una combinación de técnicas brinda un mejor resultado final en comparación con el empleo de un procedimiento de aumento puro. Presentamos la técnica quirúrgica que empleamos desde el 2003 que a nuestro juicio cumple con todos estos objetivos y puede utilizarse para aumento mamario en pacientes con ptosis leve o moderada. Describimos la técnica con detalle y discutimos las indicaciones y ventajas de incorporar estos refinamientos técnicos a la mamoplastia de aumento convencional. Recogemos 230 casos en los que se realizó mamoplastia de aumento multiplanar con disección muscular ampliada en bloque, optimizando vectores independientes para reposicionar el complejo areola-pezón en su posición ideal en casos de ptosis asociada. Agregamos puntos de anclaje percutáneos en 98 pacientes para conseguir este efecto. No hemos tenido complicaciones mayores, más allá de pequeñas dehiscencias superficiales de las heridas en 18 casos que se corrigieron con tratamiento expectante sin dejar secuelas. Con esta técnica intentamos aportar una opción más al cirujano plástico para ofrecer un resultado natural y duradero a las pacientes que se someten a mamoplastia de aumento.

  7. Structure of ion-implanted ceramics

    International Nuclear Information System (INIS)

    Naramoto, Hiroshi

    1983-01-01

    The variation of structure of LiF, MgO, Al 2 O 3 and TiO 2 accompanying annealing after ion implantation is explained. The analysis of structure is usually made by the perturbed gamma ray angular correlation, the internal electron Moessbauer method, or the ion scattering method. The results of analyses are discussed for alkali ion implantation, Fe-ion implantation, In-ion implantation, Au-ion implantation, Pt-ion implantation, Pb-ion implantation and transition metal ion implantation. The coupling of the implanted elements with lattice defects and matrix elements, and the compatibility between deposited elements and matrix crystal lattice were studied. The variation of physical properties due to ion implantation such as phase transition, volume change, the control of single crystal region, and the variation of hardness near surface were investigated, and the examples are presented. (Kato, T.)

  8. Hematoma subagudo tras mamoplastia de aumento relacionado con bulimia. Caso clínico

    Directory of Open Access Journals (Sweden)

    Vicente Plascencia-Valadez

    Full Text Available Resumen La mamoplastia de aumento con implantes es una cirugía muy común en nuestro medio, con complicaciones bien descritas en la literatura. El hematoma agudo posterior a mamoplastia de aumento tiene una incidencia del 2-10%, sin embargo los hematomas subagudos y tardíos son más raros, siendo la complicación tardía más común la contractura capsular. Presentamos el caso de una paciente de 22 años de edad a la cual se realizó mamoplastia de aumento y presentó hematoma a los 19 días de postoperatorio, tras inducirse el vómito después de ingerir alimentos con la finalidad de conservar su peso, sin conocerse previamente sus antecedentes de bulimia.

  9. Surface microhardening by ion implantation

    International Nuclear Information System (INIS)

    Singh, Amarjit

    1986-01-01

    The paper discusses the process and the underlying mechanism of surface microhardening by implanting suitable energetic ions in materials like 4145 steel, 304 stainless steel, aluminium and its 2024-T351 alloy. It has been observed that boron and nitrogen implantation in materials like 4145 steel and 304 stainless steel can produce a significant increase in surface hardness. Moreover the increase can be further enhanced with suitable overlay coatings such as aluminium (Al), Titanium (Ti) and carbon (C). The surface hardening due to implantation is attributed to precipitation hardening or the formation of stable/metastable phase or both. The effect of lithium implantation in aluminium and its alloy on microhardness with increasing ion dose and ion beam energy is also discussed. (author)

  10. Implanted-tritium permeation experiments

    International Nuclear Information System (INIS)

    Longhurst, G.R.; Holland, D.F.; Casper, L.A.; Hsu, P.Y.; Miller, L.G.; Schmunk, R.E.; Watts, K.D.; Wilson, C.J.; Kershner, C.J.; Rogers, M.L.

    1982-04-01

    In fusion reactors, charge exchange neutral atoms of tritium coming from the plasma will be implanted into the first wall and other interior structures. EG and G Idaho is conducting two experiments to determine the magnitude of permeation into the coolant streams and the retention of tritium in those structures. One experiment uses an ion gun to implant deuterium. The ion gun will permit measurements to be made for a variety of implantation energies and fluxes. The second experiment utilizes a fission reactor to generate a tritium implantation flux by the 3 He(n,p) 3 H reaction. This experiment will simulate the fusion reactor radiation environment. We also plan to verify a supporting analytical code development program, in progress, by these experiments

  11. Dental-Implantate und ihre Werkstoffe

    Science.gov (United States)

    Newesely, Heinrich

    1983-07-01

    Some new trends in materials for dental implants, which also effect in the operative techniques and implant design, are described. Advantages and shortcomings of the different material types are exemplified and correlated with their bioinert resp. bioactive functions. The practical interest in metallic implants focussed in titanium resp. oxide ceramics in the ceramic field, whereas the special goal of implant research follows from the improvement of the bioactive principle with loaded calcium phosphate implants.

  12. Biodegradable Implants in Orthopaedics and Traumatology

    OpenAIRE

    YETKIN, Haluk

    2014-01-01

    Biodegradable implants are an alternative to metallic implants and have the advantage of not being necessary to remove once the fracture has healed. Twenty-two patients with fractures were treated with biodegradable implants. There were osteolysis in eleven patients; however, no serious complication was encountered. Although biodegradable implants are expensive, a second surgical procedure to remove the implants is not necessary, relieving the patient of the related costs and risks.

  13. Basics of clinical diagnosis in implant dentistry

    Directory of Open Access Journals (Sweden)

    Manu Rathee

    2015-01-01

    Full Text Available Implant-based prosthetic rehabilitation requires an understanding of associated anatomical structures. The ultimate predictability of an implant site is determined by the existing anatomy as related to dentition and the associated hard and soft tissues. Meticulous clinical assessment helps in determining the suitability of the potential site for implant placement. The purpose of this article is to present the clinical assessment for dental implants' placement to modulate peri-implant tissue characteristics in individual clinical need.

  14. Body Implanted Medical Device Communications

    Science.gov (United States)

    Yazdandoost, Kamya Yekeh; Kohno, Ryuji

    The medical care day by day and more and more is associated with and reliant upon concepts and advances of electronics and electromagnetics. Numerous medical devices are implanted in the body for medical use. Tissue implanted devices are of great interest for wireless medical applications due to the promising of different clinical usage to promote a patient independence. It can be used in hospitals, health care facilities and home to transmit patient measurement data, such as pulse and respiration rates to a nearby receiver, permitting greater patient mobility and increased comfort. As this service permits remote monitoring of several patients simultaneously it could also potentially decrease health care costs. Advancement in radio frequency communications and miniaturization of bioelectronics are supporting medical implant applications. A central component of wireless implanted device is an antenna and there are several issues to consider when designing an in-body antenna, including power consumption, size, frequency, biocompatibility and the unique RF transmission challenges posed by the human body. The radiation characteristics of such devices are important in terms of both safety and performance. The implanted antenna and human body as a medium for wireless communication are discussed over Medical Implant Communications Service (MICS) band in the frequency range of 402-405MHz.

  15. Cochlear implants and medical tourism.

    Science.gov (United States)

    McKinnon, Brian J; Bhatt, Nishant

    2010-09-01

    To compare the costs of medical tourism in cochlear implant surgery performed in India as compared to the United States. In addition, the cost savings of obtaining cochlear implant surgery in India were compare d to those of other surgical interventions obtained as a medical tourist. Searches were conducted on Medline and Google using the search terms: 'medical tourism', 'medical offshoring', 'medical outsourcing', 'cochlear implants' and 'cochlear implantation'. The information regarding cost of medical treatment was obtained from personal communication with individuals familiar with India's cochlear implantation medical tourism industry. The range of cost depended on length of stay as well as the device chosen. Generally the cost, inclusive of travel, surgery and device, was in the range of $21,000-30,000, as compared to a cost range of $40,000-$60,000 in the US. With the escalating cost of healthcare in the United States, it is not surprising that some patients would seek to obtain surgical care overseas at a fraction of the cost. Participants in medical tourism often have financial resources, but lack health insurance coverage. While cardiovascular and orthopedic surgery performed outside the United States in India at centers that cater to medical tourists are often performed at one-quarter to one-third of the cost that would have been paid in the United States, the cost differential for cochlear implants is not nearly as favorable.

  16. Implantation damage in silicon devices

    International Nuclear Information System (INIS)

    Nicholas, K.H.

    1977-01-01

    Ion implantation, is an attractive technique for producing doped layers in silicon devices but the implantation process involves disruption of the lattice and defects are formed, which can degrade device properties. Methods of minimizing such damage are discussed and direct comparisons made between implantation and diffusion techniques in terms of defects in the final devices and the electrical performance of the devices. Defects are produced in the silicon lattice during implantation but they are annealed to form secondary defects even at room temperature. The annealing can be at a low temperature ( 0 C) when migration of defects in silicon in generally small, or at high temperature when they can grow well beyond the implanted region. The defect structures can be complicated by impurity atoms knocked into the silicon from surface layers by the implantation. Defects can also be produced within layers on top of the silicon and these can be very important in device fabrication. In addition to affecting the electrical properties of the final device, defects produced during fabrication may influence the chemical properties of the materials. The use of these properties to improve devices are discussed as well as the degradation they can cause. (author)

  17. The vestibular implant: Quo vadis?

    Directory of Open Access Journals (Sweden)

    Raymond eVan De Berg

    2011-08-01

    Full Text Available AbstractObjective: to assess the progress of the development of the vestibular implant and its feasibility short-term. Data sources: a search was performed in Pubmed, Medline and Embase. Key words used were vestibular prosth* and vestibular implant. The only search limit was language: English or Dutch. Additional sources were medical books, conference lectures and our personal experience with per-operative vestibular stimulation in patients selected for cochlear implantation.Study selection: all studies about the vestibular implant and related topics were included and evaluated by two reviewers. No study was excluded since every study investigated different aspects of the vestibular implant. Data extraction and synthesis: data was extracted by the first author from selected reports, supplemented by additional information, medical books conference lectures. Since each study had its own point of interest with its own outcomes, it was not possible to compare data of different studies. Conclusion: to use a basic vestibular implant in humans seems feasible in the very near future. Investigations show that electric stimulation of the canal nerves induces a nystagmus which corresponds to the plane of the canal which is innervated by the stimulated nerve branch. The brain is able to adapt to a higher baseline stimulation, while still reacting on a dynamic component. The best response will be achieved by a combination of the optimal stimulus (stimulus profile, stimulus location, precompensation, complemented by central vestibular adaptation. The degree of response will probably vary between individuals, depending on pathology and their ability to adapt.

  18. Imaging of common breast implants and implant-related complications: A pictorial essay.

    Science.gov (United States)

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  19. Why are mini-implants lost: the value of the implantation technique!

    Science.gov (United States)

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  20. Why are mini-implants lost: The value of the implantation technique!

    Directory of Open Access Journals (Sweden)

    Fabio Lourenço Romano

    2015-02-01

    Full Text Available The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1 Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2 Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3 Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4 The more precise the lancing procedures, the better the implant placement technique; 5 Self-drilling does not mean higher pressures; 6 Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  1. Imaging of common breast implants and implant-related complications: A pictorial essay

    Directory of Open Access Journals (Sweden)

    Amisha T Shah

    2016-01-01

    Full Text Available The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  2. Implantate in der Augenheilkunde

    Science.gov (United States)

    Dresp, Joachim H.

    Im Bereich der Augenheilkunde findet sich die weltweit am häufigsten ausgeführte chirurgische Massnahme, die operative Behandlung des Grauen Stars: die Katarakt. Bei der Katarakt handelt es sich um eine Eintrübung der natürlichen Augenlinse, die sich je nach Stadium der Erkrankung leicht opak, über milchig bis zu bräunlich präsentiert. Mit dieser Zunahme der Undurchlässigkeit für das sichtbare Licht geht eine Abnahme des Sehvermögens einher, die bis zur totalen Erblindung führen kann. Bedingt durch die sehr eingeschränkten chirurgischen Möglichkeiten in den Ländern der Dritten Welt ist die Katarakt die Erblindungsursache Nummer 1 in der Welt. Ganz im Gegensatz hierzu ist in den industrialisierten Ländern Europas, Amerikas und Asiens die Katarakt-OP die sicherste chirurgische Intervention. In der Augenheilkunde werden Implantate aller drei Aggregatszustände verwendet.

  3. Conversando con...Momoyo Kaijima

    OpenAIRE

    Gómez Alonso, Carlos; Álvarez Isidro, Eva; Torres Barchino, Ana

    2017-01-01

    [ES] Momoyo Kaijima es profesora en la Facultad de Arte y Diseño de la Universidad de Tsukuba en la Prefectura de Ibaraki y profesora visitante en la ETH de Zürich, en Royal Academy of Fine Arts, en Rice School of Architecture y en Harvard GSD. A lo largo de los años, Atelier Bow Wow ha colaborado con Krešimir Rogina, arquitecto de Zagreb y socio de la firma internacional Penezic&Rogina, en la realización del Grožnjan International Summer School of Architecture, siendo Rogina el nexo indispen...

  4. Resultados clínicos e radiológicos en serie de artrodesis cervical anterior con caja de fusión intersomática y placa Resultados clínicos e radiológicos em série de artrodese cervical anterior com dispositivo de fusão intersomática e placa Clinical and radiologica outcomes in series of anterior cervical fusion with intersomatic cage and plate

    Directory of Open Access Journals (Sweden)

    Lyonel Beaulieu Lalanne

    2012-06-01

    Full Text Available OBJETIVOS: Analizar los resultados clínicos e radiológicos de una serie de pacientes sometidos a artrodesis cervical anterior con caja de fusión intersomática (CAGE y placa. MÉTODOS: Análisis retrospectivo de serie de pacientes sometidos a artrodesis cervical anterior con caja de fusión intersomática y placa entre los años 2004 y 2009. Revisión de fichas clínicas y radiografías, registro de edad, sexo, diagnósticos, nivel operado, complicaciones, evolución clínica y radiológica. Técnica quirúrgica de Smith-Robinson. Las cajas de fusión intersomática fueron llenadas con sustitutos de huesos. Deambulación 12 horas después de la cirugía, alta a las 48 horas, collar cervical intermitente por 2 semanas. Evaluación clínica mediante criterios de Odom. Seguimiento 17 a 78 meses. RESULTADOS: Diagnósticos: Hernia del núcleo pulposo (HNP cervical, 44 (71%, mielopatía, 11 (17,7%, fracturas, 7 (11,3%. Nivel 1: 44 (71%, Nivel 2: 15 (24,2%, Nivel 3: (4,8%. El nivel C5-C6 incluyó 92% de los casos. Alivio del dolor radicular: 60 (97%. Recuperación del déficit neurológico: 59 (95,2%. Alivio de la mielopatía: 8/11 pacientes (73%. Alivio del dolor cervical: 56 (90%. Resultados clínicos: 91,9% excelentes y buenos. Complicaciones (12,9%: 4 disfagias transitorias (6,5%, 1 disfagia permanente (1,6%, 2 disfonías transitorias (3,3%, 1 subcidencia con aflojamiento del implante y fractura asintomática de placa (1,6%. No hubo pseudoartrosis. CONCLUSIONES: Esta serie presenta buenos resultados clínicos, com alivio del dolor y recuperación neurológica comparables con los hallazgos en la literatura. El uso de la caja de fusión intersomática evita complicaciones de la zona dadora y, cuando es asociado a placa cervical anterior permite fijación intersomática inmediata, dando soporte estructural adecuado, con buenos resultados y sin complicaciones a largo plazo.OBJETIVOS: Analisar os resultados clínicos e radiológicos de uma série de

  5. Precision of fit between implant impression coping and implant replica pairs for three implant systems.

    Science.gov (United States)

    Nicoll, Roxanna J; Sun, Albert; Haney, Stephan; Turkyilmaz, Ilser

    2013-01-01

    The fabrication of an accurately fitting implant-supported fixed prosthesis requires multiple steps, the first of which is assembling the impression coping on the implant. An imprecise fit of the impression coping on the implant will cause errors that will be magnified in subsequent steps of prosthesis fabrication. The purpose of this study was to characterize the 3-dimensional (3D) precision of fit between impression coping and implant replica pairs for 3 implant systems. The selected implant systems represent the 3 main joint types used in implant dentistry: external hexagonal, internal trilobe, and internal conical. Ten impression copings and 10 implant replicas from each of the 3 systems, B (Brånemark System), R (NobelReplace Select), and A (NobelActive) were paired. A standardized aluminum test body was luted to each impression coping, and the corresponding implant replica was embedded in a stone base. A coordinate measuring machine was used to quantify the maximum range of displacement in a vertical direction as a function of the tightening force applied to the guide pin. Maximum angular displacement in a horizontal plane was measured as a function of manual clockwise or counterclockwise rotation. Vertical and rotational positioning was analyzed by using 1-way analysis of variance (ANOVA). The Fisher protected least significant difference (PLSD) multiple comparisons test of the means was applied when the F-test in the ANOVA was significant (α=.05). The mean and standard deviation for change in the vertical positioning of impression copings was 4.3 ±2.1 μm for implant system B, 2.8 ±4.2 μm for implant system R, and 20.6 ±8.8 μm for implant system A. The mean and standard deviation for rotational positioning was 3.21 ±0.98 degrees for system B, 2.58 ±1.03 degrees for system R, and 5.30 ±0.79 degrees for system A. The P-value for vertical positioning between groups A and B and between groups A and R was <.001. No significant differences were found for

  6. Étude de la fidélité de l’implantation d’un programme de réadaptation au travail auprès de travailleurs de la construction ayant une dorsolombalgie Study of the implementation fidelity of a work rehabilitation program for construction workers with low back pain Estudio de la fidelidad de la implementación de un programa de rehabilitación en el trabajo para los trabajadores de la construcción con una dorsolumbalgia

    Directory of Open Access Journals (Sweden)

    Diane Berthelette

    2012-05-01

    Full Text Available Cette étude compte parmi les rares recherches évaluatives en santé et en sécurité du travail qui tentent d’ouvrir la boîte noire des interventions de réadaptation au travail afin d’en saisir les mécanismes d’action. Elle visait à décrire la variation de l’implantation d’un programme de collaboration précoce en réadaptation au travail et à apprécier son niveau de mise en application en étudiant les écarts entre le modèle prévu et les interventions dispensées. Le devis consistait en une étude descriptive de la fidélité de l’implantation du programme avec différentes unités d’analyse. L’analyse a permis, entre autres, de mettre en lumière la variation dans la mise en œuvre du programme et d’apprécier l’écart entre le programme prévu et réalisé.Few program evaluation studies on occupational health and safety have as yet been conducted. The goal of this study was to increase our understanding of the various mechanisms of a work rehabilitation program by: (1 describing the quantity and quality of the activities taking place and the resources used; and (2 estimating how faithful the implemented program was to the originally planned model. A descriptive study of the fidelity of the program’s implementation was conducted using different units of analysis. The results highlighted variations in the program’s implementation and some differences between what was planned and what was implemented.Este estudio se encuentra entre las escasas investigaciones evaluativas de salud y seguridad en el trabajo que pretenden abrir la caja negra de las intervenciones de rehabilitación en el trabajo con el fin de comprender los mecanismos de acción. El estudio se trazó como objetivo describir la variación de la implementación de un programa de colaboración precoz en rehabilitación en el trabajo y apreciar su nivel de operacionalización estudiando las diferencias entre el modelo previsto y las intervenciones

  7. Food irradiation - pros and cons

    International Nuclear Information System (INIS)

    1983-01-01

    The use of ionising radiation for food preservation is a much-disputed topic, both among experts and among consumers. Pros and cons of this issue were discussed in detail at the consumers' forum. Professor Dr. Johannes Friedrich Diehl, Director of the Institute for Biochemistry of the Food Research Centre, Karlsruhe, is a well-known supporter of the new method of food preservation; he sees advantages in the radiopreservation of food because, for example, losses due to inedibility are reduced, the danger of salmonellosis is decreased, just as the use of chemicals. He thinks this method to be without danger to health, shown by many years of experience. Opponents to food irradiation like Prof. Dr. Konrad Pfeilsticker, Professor for food science and food chemistry at the Bonn University deem the method to be unnecessary and raise the problem of qualitative changes caused in the food. In the course of the discussions, the pros and cons seemed to balance each other out. (orig./AJ) [de

  8. De paseo con los Bourbaki

    Directory of Open Access Journals (Sweden)

    Miquel Escudero

    2012-04-01

    Full Text Available Setenta y siete años después de la fundación del grupo Bourbaki, procedemos a una reflexión que puede ser útil para los estudiantes que acaso no sepan de su existencia, ni tan siquiera los de matemáticas. Sería interesante conocer que a este grupo se le debe el signo del vacío como conjunto. Con todo lo discutible que sea el método Bourbaki en su reinterpretación de la matemática, no cabe duda de su importante repercusión hasta el punto de que ha marcado una época. Hay un antes y un después tras su irrupción, ningún matemático de primera fila de la segunda mitad del siglo XX fue ajeno a su influjo, para encabezarlo o para reprobarlo. Comenzaron como una juvenil extravagancia, pero repleta de conocimientos y con decidida voluntad de aprehender el rigor de forma exhaustiva.

  9. Tratamiento del paciente con artrosis

    Directory of Open Access Journals (Sweden)

    Francisco Vargas Negrín

    2014-01-01

    Full Text Available El manejo terapéutico del paciente con artrosis tiene como objetivo disminuir la sintomatología dolorosa e inflamatoria, mejorar la capacidad funcional del paciente y la aplicación de intervenciones terapéuticas eficaces y lo más seguras posibles. Un enfoque centrado en el paciente implica su participación activa en el diseño del plan terapéutico y en la toma de decisiones informadas oportunas en todas las etapas de la enfermedad. La educación terapéutica, la actividad física y el ejercicio terapéutico junto con el control de peso, en caso de sobrepeso u obesidad, constituyen el núcleo central del tratamiento. Los autocuidados individuales y por los familiares son fundamentales en el control del día a día del paciente. El uso de terapias físicas, ayudas técnicas (bastón, etc. y de fármacos tipo analgésicos simples, opioides y antiinflamatorios tiene evidencias demostradas en el control del dolor, mejora la funcionalidad y la calidad de vida del paciente y una clara recomendación de uso en el tratamiento de la artrosis. La cirugía conservadora y la de reemplazo articular se indican en los casos en los que no se logran los objetivos terapéuticos en casos concretos.

  10. Effect of nursing-calf implant timing on growth performance and carcass characteristics.

    Science.gov (United States)

    Webb, M J; Harty, A A; Salverson, R R; Kincheloe, J J; Zuelly, S M S; Underwood, K R; Luebbe, M K; Olson, K C; Blair, A D

    2017-12-01

    The objective of this study was to compare pre- and postweaning growth performance, carcass characteristics, and meat quality attributes of calves that did not receive an implant or were implanted early or late in the nursing period. Crossbred steer calves ( = 135) were stratified by birth date and birth weight and randomly assigned to the following implant treatments: control (CON; no preweaning implant), 58 d (EARLY; 36 mg zeranol, administered at an average of 58 ± 13 d of age), and 121 d (LATE; 36 mg zeranol, administered at an average 121 ± 13 d of age). After weaning, steers were blocked by initial feed yard BW to 15 pens (5 pens/treatment and 9 steers/pen). All steers were implanted on d 21 after arrival at the feed yard and again on d 108 of finishing. Steer BW and ultrasound assessment of rib eye area (uREA), rib fat thickness (uRFT), and percent intramuscular fat (uIMF) were collected when implants were administered, at weaning, and on harvest day. Carcass measurements included HCW, rib eye area (REA), 12th-rib fat thickness (FT), and marbling score. Objective color (L*, a*, and b*) was recorded, and a 3.8-cm strip loin section was removed from both sides of each carcass and portioned into 2.54-cm steaks that were aged for 3 or 14 d for analysis of cook loss and Warner-Bratzler shear force (WBSF). The remaining portion of each sample was used for analysis of moisture and crude fat. Steer BW, ADG, and G:F did not differ among treatments ( > 0.05). Steers implanted in the EARLY treatment had a greater ( 0.05); however, steers on the CON treatment had a greater ( ≤ 0.05) percent uIMF than EARLY implanted steers, whereas steers receiving the LATE implant were intermediate and not different from the other treatments. Hot carcass weight, REA, FT, USDA yield grade, marbling score, and objective color did not differ ( > 0.05) among treatments. The proportion of steers in each USDA yield and quality grade was similar ( > 0.05) among treatments, and no

  11. Resultados de implante de lente intraocular en niños Results of intraocular lens implantation in children

    Directory of Open Access Journals (Sweden)

    Nashelly I. Mejía Cruz

    2007-12-01

    Full Text Available En este estudio se describen los resultados obtenidos del implante de lente intraocular en niños, quienes acudieron al servicio de Oftalmología Pediátrica de Instituto Cubano de oftalmología “Ramón Pando Ferrer” con el diagnóstico de catarata de diversas etiologías, en período comprendido entre abril del 2002 al 2005 cuyo seguimiento fue durante un año. En nuestro universo de estudio se determinan algunos parámetros como la edad del paciente, etiología de las cataratas, agudeza visual, defecto refractivo preoperatorio y posoperatorio. Se identificó el poder dióptrico del lente intraocular más frecuente, la presencia de complicaciones durante la cirugía y después de esta. Se evaluaron finalmente, los pacientes que requerían de tratamiento adicional como la capsulotomía con láser o membranectomía quirúrgica. El implante del lente intraocular a temprana edad se relacionó con buenos resultados quirúrgicos: mejoría de la agudeza visual corregida, presentándose el astigmatismo como el error refractivo más frecuente. La complicación transoperatorio y postoperatoria más frecuente fue la membrana inflamatoria, mientras que la complicación posoperatoria más frecuente fue la opacidad de la cápsula posterior.This paper described the results of the intraocular lens implantation performed in children, who had been seen at the Pediatric Ophthalmologic Service of " Ramon Pando Ferrer " Cuban Institute of Ophthalmology and had been diagnosed as having cataract of various etiologies, from April 2002 to April 2005. They were all followed-up for a year. Some parameters like the patient’s age, the etiology of cataract, visual acuity, pre-operative and post-operative refractive defect were considered in our study. The dioptric power of the most common intraocular lens and the most frequent complications during and after surgery were identified. The patients requiring additional treatment such as laser capsulotomy and surgical

  12. Falha prematura em implantes orais = Early oral implant failures

    Directory of Open Access Journals (Sweden)

    Fadanelli, Alexandro Bianchi

    2005-01-01

    Full Text Available Atualmente, ainda há uma percentagem significativa de fracassos de implantes na prática clínica, causando transtorno para o profissional e para o paciente. O objetivo deste estudo foi avaliar a bibliografia disponível sobre o assunto, apresentar um caso clínico e discutir os aspectos relacionados aos insucessos na terapia com implantes ocorridos durante o período de osteointegração. A avaliação da literatura mostrou haverem múltiplos fatores possivelmente envolvidos nas falhas de implantes, sendo que através do estudo das falhas pode-se minimizar sua ocorrência

  13. Medical implants and methods of making medical implants

    Science.gov (United States)

    Shaw, Wendy J; Yonker, Clement R; Fulton, John L; Tarasevich, Barbara J; McClain, James B; Taylor, Doug

    2014-09-16

    A medical implant device having a substrate with an oxidized surface and a silane derivative coating covalently bonded to the oxidized surface. A bioactive agent is covalently bonded to the silane derivative coating. An implantable stent device including a stent core having an oxidized surface with a layer of silane derivative covalently bonded thereto. A spacer layer comprising polyethylene glycol (PEG) is covalently bonded to the layer of silane derivative and a protein is covalently bonded to the PEG. A method of making a medical implant device including providing a substrate having a surface, oxidizing the surface and reacting with derivitized silane to form a silane coating covalently bonded to the surface. A bioactive agent is then covalently bonded to the silane coating. In particular instances, an additional coating of bio-absorbable polymer and/or pharmaceutical agent is deposited over the bioactive agent.

  14. An Unusual Bone Loss Around Implants

    Directory of Open Access Journals (Sweden)

    Amirreza Rokn

    2013-01-01

    Full Text Available AbstractPre-implant disease is an inflammatory process, which can affect the surrounding tissues of a functional Osseointegrated implant that is usually as a result of a disequilibrium between the micro-flora and the body defense system.This case reports a 57 years old male with unusual bone loss around dental implants.This was an unusual case of peri-implantitis which occurred only in the implants on one side of the mouth although they all were unloaded implants.

  15. Occlusal considerations for dental implant restorations.

    Science.gov (United States)

    Bergmann, Ranier H

    2014-01-01

    When placed, dental implants are put into an ever-changing oral environment in which teeth can continue to migrate. Yet, the implants themselves are ankylosed. This can lead to occlusal instability. Teeth may continue to erupt, leaving the implants in infraocclusion. Teeth may move mesially away from an implant, requiring modification to close an open contact point. Friction in the connection between teeth and implants can lead to intrusion of teeth and damage to the periodontal attachment apparatus. Implant occlusion with shallow incisal guidance minimizes lateral and tipping forces. Cross-arch stabilization allows the best distribution of occlusal forces. The choice of restorative materials influences long-term occlusal stability.

  16. Current trends in ion implantation

    International Nuclear Information System (INIS)

    Gwilliam, R.M.

    2001-01-01

    As semiconductor device dimensions continue to shrink, the drive beyond 250 nm is creating significant problems for the device processor. In particular, trends toward shallower-junctions, lower thermal budgets and simplified processing steps present severe challenges to ion implantation. In parallel with greater control of the implant process goes the need for a better understanding of the physical processes involved during implantation and subsequent activation annealing. For instance, the need for an understanding of dopant-defect interaction is paramount as defects mediate a number of technologically important phenomena such as transient enhanced diffusion and impurity gettering. This paper will outline the current trends in the ion implantation and some of the challenges it faces in the next decade, as described in the semiconductor roadmap. It will highlight some recent positron annihilation work that has made a contribution to addressing one of these challenges, namely the need for tighter control of implant uniformity and dose. Additionally, some vacancy-mediated processes are described with the implication that these may provide areas in which positron annihilation spectroscopy could make a significant contribution. (orig.)

  17. Composite fibrous glaucoma drainage implant

    Science.gov (United States)

    Klapstova, A.; Horakova, J.; Shynkarenko, A.; Lukas, D.

    2017-10-01

    Glaucoma is a frequent reason of loss vision. It is usually caused by increased intraocular pressure leading to damage of optic nerve head. This work deals with the development of fibrous structure suitable for glaucoma drainage implants (GDI). Commercially produced metallic glaucoma implants are very effective in lowering intraocular pressure. However, these implants may cause adverse events such as damage to adjacent tissue, fibrosis, hypotony or many others [1]. The aim of this study is to reduce undesirable properties of currently produced drains and improve their properties by creating of the composite fibrous drain for achieve a normal intraocular pressure. Two types of electrospinning technologies were used for the production of very small tubular implants. First type was focused for production of outer part of tubular drain and the second type of electrospinning method made the inner part of shape follows the connections of both parts. Complete implant had a special properties suitable for drainage of fluid. Morphological parameters, liquid transport tests and in-vitro cell adhesion tests were detected.

  18. Cranioplasty with individual titanium implants

    Science.gov (United States)

    Mishinov, S.; Stupak, V.; Sadovoy, M.; Mamonova, E.; Koporushko, N.; Larkin, V.; Novokshonov, A.; Dolzhenko, D.; Panchenko, A.; Desyatykh, I.; Krasovsky, I.

    2017-09-01

    Cranioplasty is the second procedure in the history of neurosurgery after trepanation, and it is still relevant despite the development of civilization and progress in medicine. Each cranioplasty operation is unique because there are no two patients with identical defects of the skull bones. The development of Direct Metal Laser Sintering (DMLS) technique opened up the possibility of direct implant printing of titanium, a biocompatible metal used in medicine. This eliminates the need for producing any intermediate products to create the desired implant. We have produced 8 patient-specific titanium implants using this technique for patients who underwent different decompressive cranioectomies associated with bone tumors. Follow-up duration ranged from 6 to 12 months. We observed no implant-related reactions or complications. In all cases of reconstructive neurosurgery we achieved good clinical and aesthetic results. The analysis of the literature and our own experience in three-dimensional modeling, prototyping, and printing suggests that direct laser sintering of titanium is the optimal method to produce biocompatible surgical implants.

  19. Aqueous shunt implantation in glaucoma

    Directory of Open Access Journals (Sweden)

    Jing Wang

    2017-01-01

    Full Text Available Aqueous shunts or glaucoma drainage devices are increasingly utilized in the management of refractory glaucoma. The general design of the most commonly-used shunts is based on the principles of the Molteno implant: ie. a permanent sclerostomy (tube, a predetermined bleb area (plate and diversion of aqueous humour to the equatorial region and away from the limbal subconjunctival space. These three factors make aqueous shunts more resistant to scarring as compared to trabeculectomy. The two most commonly used shunts are the Ahmed Glaucoma Valve, which contains a flow-restrictor, and the non-valved Baervedlt Glaucoma Implant. While the valved implants have a lower tendency to hypotony and related complications, the non-valved implants with larger, more-biocompatible end plate design, achieve lower intraocular pressures with less encapsulation. Non-valved implants require additional suturing techniques to prevent early hypotony and a number of these methods will be described. Although serious shunt-related infection is rare, corneal decompensation and diplopia are small but significant risks.

  20. Capacitive Feedthroughs for Medical Implants.

    Science.gov (United States)

    Grob, Sven; Tass, Peter A; Hauptmann, Christian

    2016-01-01

    Important technological advances in the last decades paved the road to a great success story for electrically stimulating medical implants, including cochlear implants or implants for deep brain stimulation. However, there are still many challenges in reducing side effects and improving functionality and comfort for the patient. Two of the main challenges are the wish for smaller implants on one hand, and the demand for more stimulation channels on the other hand. But these two aims lead to a conflict of interests. This paper presents a novel design for an electrical feedthrough, the so called capacitive feedthrough, which allows both reducing the size, and increasing the number of included channels. Capacitive feedthroughs combine the functionality of a coupling capacitor and an electrical feedthrough within one and the same structure. The paper also discusses the progress and the challenges of the first produced demonstrators. The concept bears a high potential in improving current feedthrough technology, and could be applied on all kinds of electrical medical implants, even if its implementation might be challenging.

  1. Cons ICARUS, TIGER and Fascism

    Directory of Open Access Journals (Sweden)

    Janez Vrečko

    2010-12-01

    Full Text Available Like the scientists of their time, Russian artists in the 1920s considered gravity the central problem – a view which points to the close harmony between modern physics and the avant-garde. It was only with the constructivist movement that the Icarus revolution grasped the principles of the “mobile philosophy” (3.651 which was almost at the same time recognised by modern physics as well. The static view of the world became obsolete, space and time were no longer absolute values. It was necessary to transcend Euclidean geometry, shake off the political ʻshackles on one’s hands’ and surrender to Lisicki’s imaginary space, where “At 2000 metres in the air / there is no more perspective” (Integrals 276.  Kosovel’s Icarus project accorded with Tatlin’s, and both of them accorded with the quintessential aims of the constructivist movement. It is no accident that Kosovel wished to name one of his poetry collections The Dream of Icarus. Poems on the Icarus theme, such as “Cons Icarus”, “Evacuation of the Spirit”, “Eh, Hey”, “A Heart in Alcohol” etc. belong to the group of Kosovel’s conses which follow his “mobile philosophy” (3.650 and “letters growing into space” (Int. 282.  The question “Man, do you want up in the air?” (Int. 128 will remain a question until the moment when man is finally ready to transcend the existing boundary and dive “beyond”. Hence Kosovel’s clear-cut contrast between the “green windows of an illuminated / express on a viaduct”, which moves horizontally and is, like a water current, subject to the earth’s gravity, and “the spirit in space”, whose direction of motion is “the perpendicular of the spirit”, atectonicity. “The spirit burns in space”: fire is an element that knows vertical movement alone, the only one of the elements to outgrow and transcend the earth’s gravity, therefore it is associated with another mythological figure important for

  2. A new system of implant abutment connection: how to improve a two piece implant system sealing.

    Science.gov (United States)

    Grecchi, F; DI Girolamo, M; Cura, F; Candotto, V; Carinci, F

    2017-01-01

    Implant dentistry has become one of the most successful dentistry techniques for replacing missing teeth. The success rate of implant dentistry is above 80%. However, peri-implantitis is a later complication of implant dentistry that if untreated, can lead to implant loss. One of the hypotized causes of peri-implantis is the bacterial leakage at the level of implant-abutment connection. Bacterial leakage is favored to the presence of a micro gap at the implant-abutment interface, allowing microorganisms to penetrate and colonize the inner part of the implant leading to biofilm accumulation and consequently to peri-implantitis development. To identify the capability of the implant to protect the internal space from the external environment, the passage of genetically modified Escherichia coli across implant-abutment interface was evaluated. Implants were immerged in a bacterial culture for twenty-four hours and then bacteria amount was measured inside implant-abutment interface with Real-time PCR. Bacteria were detected inside all studied implants, with a median percentage of 9%. The reported results are better to those of previous studies carried out on different implant systems. Until now, none implant-abutment system has been proven to seal the gap between implant and abutment.

  3. Comparison of titanium mesh implants with PLA-hydroxyapatite coatings for maxillofacial cancer reconstruction

    Science.gov (United States)

    Tverdokhlebov, S. I.; Choinzonov, E. L.; Kolokolova, O. V.; Cherdyntseva, N. V.

    2016-08-01

    Since 2013 physics of TPU and oncologists from the TCRI with participation of the "ConMet" company (Moscow) and the "Sintel" company (Tomsk Special Economic Zone resident) have been working on the theme entitled "Development of the composite implants for reconstructive surgery of a craniofacial areas of the traumatological and oncological patients" supported with the Federal Program "R&D, part 1.3". The goal was to develop the maxillo-facial implants on the basis of the transformable titanium mesh with PLA & hydroxyapatite coating. According to the Contract No. 14.578.21.0031, the team of developers had to start supplying these advanced implants to the industrial partners up to 2017. This research was supported with the preliminary market researches by the ISPMS SB RAS and the TP "MF". The stages of preliminary market researches were: 1) research of the Worldwide CMF market; 2) forecasting the BRIC CMF market up to 2020; 3) the total Russian market (epidemiology) estimation as a sum of official calculations and statistics; 4) looking for the best foreign analogue prices, comparing their and our implant properties; 5) search for the best Russian analogues; 6) the investigation of the world patent database Espacenet for the last years, and finding the owners and applicants of patents of CMF osteosynthesis plates on the basis of titanium coated with PLA & hydroxyapatite; 7) comparison of the domestic implants, and making conclusions. Several variants of the meshes have got the equal quality with the best foreign and Russian implants. The closest analogues were titanium, polyethylene, PEEK composite meshes suited to the patient shape by the Synthes company in 2014, and the only hybrid titanium "Grey" implant with layers of gelatin, dextran, collagen, HAP & BMP-2 was found. This implant was produced by Russian institution, and it was mentioned in the report on clinical trials by L.A. Pavlova et al., 2014 [1]. There are no manufacturers of the coated implants in Russia

  4. Fare astronomia con piccoli telescopi

    CERN Document Server

    Gainer, Michael K

    2007-01-01

    Non sono necessariamente richiesti strumenti mastodontici per produrre risultati scientificamente validi nel campo dell’astronomia. Anche l’astrofilo dotato di un piccolo telescopio, con un diametro di soli 8-9 cm, può contribuire alla scienza del cielo realizzando utili osservazioni del Sole, della Luna, dei pianeti, delle comete, degli asteroidi, delle stelle doppie o variabili, delle nebulose e degli ammassi stellari. Il manuale di M.K. Gainer spiega quale sia la dotazione minima (un piccolo telescopio, un computer, una semplice fotocamera digitale), come utilizzarla, e quali siano le tecniche appropriate da adottare nelle osservazioni. Offre inoltre schemi per interpretare e ridurre i dati raccolti, nonché schede da compilare e da spedire ai centri di raccolta internazionali. Questo libro è il passaporto grazie al quale l’astrofilo può entrare a pieno titolo nel mondo affascinante della scienza astronomica.

  5. Cortical Plasticity after Cochlear Implantation

    DEFF Research Database (Denmark)

    Petersen, Bjørn; Gjedde, Albert; Wallentin, Mikkel

    2013-01-01

    recently implanted adult implant recipients listened to running speech or speech-like noise in four sequential PET sessions at each milestone. CI listeners with postlingual hearing loss showed differential activation of left superior temporal gyrus during speech and speech-like stimuli, unlike CI listeners...... with prelingual hearing loss. Furthermore, Broca's area was activated as an effect of time, but only in CI listeners with postlingual hearing loss. The study demonstrates that adaptation to the cochlear implant is highly related to the history of hearing loss. Speech processing in patients whose hearing loss...... occurred after the acquisition of language involves brain areas associated with speech comprehension, which is not the case for patients whose hearing loss occurred before the acquisition of language. Finally, the findings confirm the key role of Broca's area in restoration of speech perception, but only...

  6. Tinting of intraocular lens implants

    Energy Technology Data Exchange (ETDEWEB)

    Zigman, S.

    1982-06-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users.

  7. MRI of orbital hydroxyapatite implants

    International Nuclear Information System (INIS)

    Flanders, A.E.; De Potter P.; Rao, V.M.; Tom, B.M.; Shields, C.L.; Shields, J.A.

    1996-01-01

    Our aim was to use MRI for the postsurgical assessment of a new form of integrated orbital implant composed of a porous calcium phosphate hydroxyapatite substrate. We studied ten patients 24-74 years of age who underwent enucleation and implantation of a hydroxyapatite ball; 5-13 months after surgery, each patient was examined by spin-echo MRI, with fat suppression and gadolinium enhancement. Fibrovascular ingrowth was demonstrated in all ten patients as areas of enhancement at the periphery of the hydroxyapatite sphere that extended to the center to a variable degree. The radiologist should aware of the MRI appearances of the coralline hydroxyapatite orbital implant since it is now widely used following enucleation. MRI is a useful means to determine successful incorporation of the substrate into the orbital tissues. The normal pattern of contrast enhancement should not be mistaken for recurrent tumor or infection. (orig.)

  8. Tinting of intraocular lens implants

    International Nuclear Information System (INIS)

    Zigman, S.

    1982-01-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users

  9. Implant rehabilitation in bruxism patient

    Science.gov (United States)

    Goiato, Marcelo Coelho; Sonego, Mariana Vilela; dos Santos, Daniela Micheline; da Silva, Emily Vivianne Freitas

    2014-01-01

    A white female patient presented to the university clinic to obtain implant retained prostheses. She had an edentulous maxillary jaw and presented three teeth with poor prognosis (33, 34 and 43). The alveolar bone and the surrounding tissues were healthy. The patient did not report any relevant medical history contraindicating routine dental treatment or implant surgery, but self-reported a dental history of asymptomatic nocturnal bruxism. The treatment plan was set and two Branemark protocols supported by six implants in each arch were installed after a 6-month healing period. A soft occlusal splint was made due to the patient's history of bruxism, and the lack of its use by the patient resulted in an acrylic fracture. The prosthesis was repaired and the importance of using the occlusal splint was restated. In the 4-year follow-up no fractures were reported. PMID:24907215

  10. MR imaging of breast implants.

    Science.gov (United States)

    Gorczyca, D P

    1994-11-01

    MR imaging has proved to be an excellent imaging modality in locating free silicone and evaluating an implant for rupture, with a sensitivity of approximately 94% and specificity of 97%. Silicone has a unique MR resonance frequency and long T1 and T2 relaxation times, which allows several MR sequences to provide excellent diagnostic images. The most commonly used sequences include T2-weighted, STIR, and chemical shift imaging (Figs. 3, 13, and 14). The T2-weighted and STIR sequences are often used in conjunction with chemical water suppression. The most reliable findings on MR images for detection of implant rupture include identification of the collapsed implant shell (linguine sign) and free silicone within the breast parenchyma.

  11. Technological tendencies and their relation with energy markets; Tendencias tecnologicas y su relacion con mercados de energia

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Castro, Salvador [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    1999-07-01

    In this article some associate technological tendencies with areas of interest of the Control Systems Division of the Instituto de Investigaciones Electricas (IIE) are presented. Here the relations or influence that these tendencies have and will continue having in the future with the definition and implantation of energy markets are mentioned. [Spanish] En este articulo se presentan algunas tendencias tecnologicas asociadas con areas de interes de la Division de Sistemas de Control del Instituto de Investigaciones Electricas (IIE). Aqui se mencionan las relaciones o influencia que dichas tendencias tienen y continuaran teniendo en el futuro con la definicion e implantacion de mercados de energia.

  12. Reparación del cartílago articular con injerto libre de pericondrio estudio experimental

    OpenAIRE

    Ballesteros Vazquez, P.; Carranza Bencano, Andrés; Armas Padrón, J. R.; Saenz López de Rueda, F.

    1994-01-01

    Ante la incapacidad de regeneración espontánea de lesiones profundas y amplias del cartílago articular, estudiamos la reparación cartilaginosa con plastias de pericondrio tomadas de la región condro-costal e implantándolas con su cara condrogénica sobre una lesión osteocondral realizada en la superficie articular rotuliana. Macroscópica e histológicamente, a la octava semana, el neocartílago formado tenía igual apariencia que el cartílago hialino normal, no existiendo separació...

  13. Radioactive implants for medical applications; Radioaktive Implantate fuer medizinische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, M.

    2008-07-01

    The long-term success of surgery is often diminished by excessive wound healing, which makes another intervention necessary. Locally applied radionuclides with short range radiation can prevent such benign hyperproliferation. As pure electron emitter with a half-life of 14.3 days and a mean energy of 694.9 keV (E{sub max}=1710.48 keV) {sup 32}P is a suitable radionuclide which can be produced from the stable {sup 31}P by the capture of thermal neutrons (1 x 10{sup 14} /s/cm{sup 2}) in a nuclear reactor. After a typical irradiation time (14 days) the ratio of {sup 32}P to {sup 31}P is 1.4 x 10{sup -5} to 1. Implants made of polymer and/or bioabsorbable material functioning as a carrier of the radioactive emitter allow - as opposed to metallic implants - for new applications for this type of radiotherapy. In this thesis a manufacturing method for previously not available organic, radioactive implants has been developed and a corresponding dosimetry system has been established. By means of ion implantation, {sup 32}P ions with up to 180 keV can be shot some 100 nm deep into organic implant materials. For a typical dose (15 Gy over 7 days, 1 mm distance from the implant) an activity of 75 kBq is needed corresponding to 1.3 x 10{sup 11} {sup 32}P ions. The sputter ion gun, which has been optimized for this application, creates an ion beam with high beam current (> 14 {mu}A P{sup -}) and low emittance (< 4 {pi} mm mrad {radical}(MeV)). Because of the good beam quality also small implants (<1 mm{sup 2}) can be manufactured with high efficiency. The unintentionally co-implanted portion of molecules and nuclides of the same mass (e.g. {sup 31}PH, {sup 16}O{sub 2} and {sup 32}S) could be reduced from approximately 500 to 50 by an improvement of the isotope selection at {sup 32}P beam creation. Hence, in comparison with the best hitherto existing implantation methods, the radiation dose of the implant could be reduced by an order of magnitude. With regard to the beta

  14. Surface engineering by ion implantation

    International Nuclear Information System (INIS)

    Nielsen, Bjarne Roger

    1995-01-01

    Awidespread commercial applica tion iof particle accelerators is for ion implantation. Accelerator beams are used for ion implantation into metals, alloying a thin surface layer with foreign atoms to concentrations impossible to achieve by thermal processes, making for dramatic improvements in hardness and in resistance to wear and corrosion. Traditional hardening processes require high temperatures causing deformation; ion implantation on the other hand is a ''cold process'', treating the finished product. The ionimplanted layer is integrated in the substrate, avoiding the risk of cracking and delamination from normal coating processes. Surface properties may be ''engineered'' independently of those of the bulk material; the process does not use environmentally hazardous materials such as chromium in the surface coating. The typical implantation dose required for the optimum surface properties of metals is around 2 x 10 17 ion/cm 2 , a hundred times the typical doses for semiconductor processing. When surface areas of more than a few square centimetres have to be treated, the implanter must therefore be able to produce high beam currents (5 to 10 mA) to obtain an acceptable treatment time. Ion species used include nitrogen, boron, carbon, titanium, chromium and tantalum, and beam energies range from 50 to 200 keV. Since most components are three dimensional, it must be possible to rotate and tilt them in the beam, and control beam position over a large area. Examples of industrial applications are: - surface treatment of prostheses (hip and knee joints) to reduce wear of the moving parts, using biocompatible materials; - ion implantation into high speed ball bearings to protect against the aqueous corrosion in jet engines (important for service helicopters on oil rigs); - hardening of metal forming and cutting tools; - reduction of corrosive wear of plastic moulding tools, which are expensive to produce

  15. Carbon Fiber Biocompatibility for Implants

    Directory of Open Access Journals (Sweden)

    Richard Petersen

    2016-01-01

    Full Text Available Carbon fibers have multiple potential advantages in developing high-strength biomaterials with a density close to bone for better stress transfer and electrical properties that enhance tissue formation. As a breakthrough example in biomaterials, a 1.5 mm diameter bisphenol-epoxy/carbon-fiber-reinforced composite rod was compared for two weeks in a rat tibia model with a similar 1.5 mm diameter titanium-6-4 alloy screw manufactured to retain bone implants. Results showed that carbon-fiber-reinforced composite stimulated osseointegration inside the tibia bone marrow measured as percent bone area (PBA to a great extent when compared to the titanium-6-4 alloy at statistically significant levels. PBA increased significantly with the carbon-fiber composite over the titanium-6-4 alloy for distances from the implant surfaces of 0.1 mm at 77.7% vs. 19.3% (p < 10−8 and 0.8 mm at 41.6% vs. 19.5% (p < 10−4, respectively. The review focuses on carbon fiber properties that increased PBA for enhanced implant osseointegration. Carbon fibers acting as polymer coated electrically conducting micro-biocircuits appear to provide a biocompatible semi-antioxidant property to remove damaging electron free radicals from the surrounding implant surface. Further, carbon fibers by removing excess electrons produced from the cellular mitochondrial electron transport chain during periods of hypoxia perhaps stimulate bone cell recruitment by free-radical chemotactic influences. In addition, well-studied bioorganic cell actin carbon fiber growth would appear to interface in close contact with the carbon-fiber-reinforced composite implant. Resulting subsequent actin carbon fiber/implant carbon fiber contacts then could help in discharging the electron biological overloads through electrochemical gradients to lower negative charges and lower concentration.

  16. Artrosis de tobillo y su tratamiento con artroplastía total de tobillo

    Directory of Open Access Journals (Sweden)

    Beat Hintermann, DR.

    2014-09-01

    Resultados clínicos alentadores para artroplastias de segunda generación son prometedores para pacientes con osteoartritis avanzada del tobillo. Sin embargo, las características mecánicas y fisiológicas únicas de la articulación del tobillo siguen siendo un desafío. A la fecha, los fracasos de implantes de tobillo continúan siendo más altos que implantes para otras articulaciones. De cierto modo, esto puede estar relacionado con la inhabilidad del cirujano para restaurar adecuadamente el rol estabilizador crítico de los ligamentos junto con una reproducción insuficiente de la mecánica normal de la articulación del tobillo. Sin embargo, la selección adecuada de pacientes, planificación preoperatoria cuidadosa, tratamiento apropiado de trastornos asociados (por ejemplo, inestabilidad, mal alineación y osteoartritis de articulaciones adyacentes y la minimización de complicaciones perioperatorias, ayudarán a maximizar la posibilidad de un resultado exitoso.

  17. Neutrophil Responses to Sterile Implant Materials.

    Directory of Open Access Journals (Sweden)

    Siddharth Jhunjhunwala

    Full Text Available In vivo implantation of sterile materials and devices results in a foreign body immune response leading to fibrosis of implanted material. Neutrophils, one of the first immune cells to be recruited to implantation sites, have been suggested to contribute to the establishment of the inflammatory microenvironment that initiates the fibrotic response. However, the precise numbers and roles of neutrophils in response to implanted devices remains unclear. Using a mouse model of peritoneal microcapsule implantation, we show 30-500 fold increased neutrophil presence in the peritoneal exudates in response to implants. We demonstrate that these neutrophils secrete increased amounts of a variety of inflammatory cytokines and chemokines. Further, we observe that they participate in the foreign body response through the formation of neutrophil extracellular traps (NETs on implant surfaces. Our results provide new insight into neutrophil function during a foreign body response to peritoneal implants which has implications for the development of biologically compatible medical devices.

  18. Fractographic analysis of fractured dental implant components

    Directory of Open Access Journals (Sweden)

    Chih-Ling Chang

    2013-03-01

    Conclusion: To avoid implant fracture, certain underlying mechanical risk factors should be noted such as patients with a habit of bruxism, bridgework with a cantilever design, or two implants installed in a line in the posterior mandible.

  19. Production of amorphous alloys by ion implantation

    International Nuclear Information System (INIS)

    Grant, W.A.; Chadderton, L.T.; Johnson, E.

    1978-01-01

    Recent data are reported on the use of ion implantation to produce amorphous metallic alloys. In particular data on the dose dependence of the crystalline to amorphous transition induced by P + implantation of nickel is presented. (Auth.)

  20. Dental implant surgery: planning and guidance

    International Nuclear Information System (INIS)

    Lobregt, S.; Schillings, J.J.; Vuurberg, E.

    2001-01-01

    A prototype application has been developed for interactive planning of dental implants on the EasyVision workstation. The user is led step by step via virtual positioning of the implant to the design of a customized drill guide. (orig.)

  1. Preparation of targets by ion implantation

    International Nuclear Information System (INIS)

    Santry, D.C.

    1976-01-01

    Various factors are described which are involved in target preparation by direct ion implantation and the limitations and pitfalls of the method are emphasized. Examples are given of experiments for which ion implanted targets are well suited. (author)

  2. Surgical Templates for Dental Implant Positioning; Current ...

    African Journals Online (AJOL)

    prosthodontics; however, designing an implant‑supported prosthesis with function .... template where a provisional fixed restoration bridges the implant site. Pesun and ... in single implant therapy or short‑span implant‑supported prostheses.

  3. Implants in free fibula flap supporting dental rehabilitation - Implant and peri-implant related outcomes of a randomized clinical trial.

    Science.gov (United States)

    Kumar, Vinay V; Ebenezer, Supriya; Kämmerer, Peer W; Jacob, P C; Kuriakose, Moni A; Hedne, Naveen; Wagner, Wilfried; Al-Nawas, Bilal

    2016-11-01

    The objective of this study was to assess the difference in success rates of implants when using two or four implant-supported-overdentures following segmental mandibular reconstruction with fibula free flap. This prospective, parallel designed, randomized clinical study was conducted with 1:1 ratio. At baseline, all participants already had segmental reconstruction of mandible with free fibula flap. The participants were randomized into two groups: Group-I received implant-supported-overdentures on two tissue-level implants and Group-II received implant-supported-overdentures on four tissue-level implants. Success rates of the implants were evaluated at 3 months, 6 months and 12 months following implant loading using marginal bone level changes as well as peri-implant indices (Buser et al., 1990). 52 patients were randomized into two treatment groups (26 each), out of which 18 patients (36 implants) of Group-I and 17 patients (68 implants) of Group-II were evaluated. One implant in Group-I was lost due to infective complications and one patient in the same group had superior barrel necrosis. There was a statistically significant increase at both time points (p = 0.03, p = 0.04 at 6 months, 12 months) in the amount of marginal bone loss in Group-I (0.4 mm, 0.5 mm at 6 months, 12 months) as compared to Group-II (0.1 mm, 0.2 mm at 6 months, 12 months). There were no clinically significant changes peri-implant parameters between both groups. Peri-implant soft tissue hyperplasia was seen in both groups, 32% of implants at 3-months, 26% at 6-months and 3% at 12-months follow-up. The results of this study show that patients with 2-implant-supported-overdentures had higher marginal bone loss as compared to patients with 4-implant-supported-overdentures. There were no clinically significant differences in peri-implant soft tissue factors in patients with 2- or 4-implant-supported-overdentures. Hyperplastic peri-implant tissues are common in the early implant

  4. Implant surface preparation in the surgical treatment of experimental peri-implantitis with autogenous bone graft and ePTFE membrane in cynomolgus monkeys

    DEFF Research Database (Denmark)

    Schou, Søren; Holmstrup, Palle; Jørgensen, Torben

    2003-01-01

    peri-implantitis; treatment; implant surface preparation; nonhuman primates; histology; stereology......peri-implantitis; treatment; implant surface preparation; nonhuman primates; histology; stereology...

  5. Impact of cone-beam computed tomography on implant planning and on prediction of implant size

    Energy Technology Data Exchange (ETDEWEB)

    Pedroso, Ludmila Assuncao de Mello; Silva, Maria Alves Garcia Santos, E-mail: ludmilapedroso@hotmail.com [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia; Garcia, Robson Rodrigues [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Medicina Oral; Leles, Jose Luiz Rodrigues [Universidade Paulista (UNIP), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Cirurgia; Leles, Claudio Rodrigues [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Prevencao e Reabilitacao Oral

    2013-11-15

    The aim was to investigate the impact of cone-beam computed tomography (CBCT) on implant planning and on prediction of final implant size. Consecutive patients referred for implant treatment were submitted to clinical examination, panoramic (PAN) radiography and a CBCT exam. Initial planning of implant length and width was assessed based on clinical and PAN exams, and final planning, on CBCT exam to complement diagnosis. The actual dimensions of the implants placed during surgery were compared with those obtained during initial and final planning, using the McNemmar test (p < 0.05). The final sample comprised 95 implants in 27 patients, distributed over the maxilla and mandible. Agreement in implant length was 50.5% between initial and final planning, and correct prediction of the actual implant length was 40.0% and 69.5%, using PAN and CBCT exams, respectively. Agreement in implant width assessment ranged from 69.5% to 73.7%. A paired comparison of the frequency of changes between initial or final planning and implant placement (McNemmar test) showed greater frequency of changes in initial planning for implant length (p < 0.001), but not for implant width (p = 0.850). The frequency of changes was not influenced by implant location at any stage of implant planning (chi-square test, p > 0.05). It was concluded that CBCT improves the ability of predicting the actual implant length and reduces inaccuracy in surgical dental implant planning. (author)

  6. Implantable Cardiac Pacemakers – 50 Years from the First Implantation

    Directory of Open Access Journals (Sweden)

    Ratko Magjarević

    2010-01-01

    Overview: Development of implantable cardiac pacemaker was enabled by another important invention, the silicon transistor. h ough the invention of suitable lithium cells as appropriate power supply was essential for prolongation of battery life cycle and for increased reliability of pacemakers, main milestones in the development were associated with technological breakthroughs in electronics: from transistors, which introduced such features as small size and low power consumption, to hybrid and integrated circuits, which enabled programmability, microprocessors, which added more options in programming (multiprogrammability, diagnostics and telemetry, and the ICT (information communication technology that enabled physicians remote access to patients and interrogation of their implantable devices. Conclusions: Implantable pacemakers are reliable devices indicated for a wide range of dif erent therapies of cardiac rhythm disorders and heart failure. h ere is still a lot to learn about the physiology of a normal heart and even more about the failing heart. Modern pacemakers provide physicians valuable information from pacemakers’ memory via the built-in telemetry system. h ese information help physicians to better understand pathologic processes within the heart, thus contributing to the development of new ideas for treatment of diseases and for precise tailoring of the therapy to the patient’s needs. Although implantable pacemakers have reached the level of mature technology, they will continue to develop with therapies and diagnostics to facilitate a higher quality of life.

  7. Augmentation Mammaplasty Using Implants: A Review

    Directory of Open Access Journals (Sweden)

    Susumu Takayanagi

    2012-09-01

    Full Text Available One of the techniques for augmentation mammaplasty is the procedure using implants. Even though this technique has been used for many years, there are still several controversial issues to be discussed and overcome for patient safety. In this review article, capsular contracture, leak or rupture of the implants, possible systemic disease, relation with breast cancer, and recent problems with Poly Implant Prothese implants are described and discussed.

  8. Augmentation Mammaplasty Using Implants: A Review

    Directory of Open Access Journals (Sweden)

    Susumu Takayanagi

    2012-09-01

    Full Text Available One of the techniques for augmentation mammaplasty is the procedure using implants. Eventhough this technique has been used for many years, there are still several controversial issuesto be discussed and overcome for patient safety. In this review article, capsular contracture,leak or rupture of the implants, possible systemic disease, relation with breast cancer, andrecent problems with Poly Implant Prothese implants are described and discussed.

  9. Plasma immersion ion implantation into insulating materials

    International Nuclear Information System (INIS)

    Tian Xiubo; Yang Shiqin

    2006-01-01

    Plasma immersion ion implantation (PIII) is an effective surface modification tool. During PIII processes, the objects to be treated are immersed in plasmas and then biased to negative potential. Consequently the plasma sheath forms and ion implantation may be performed. The pre-requirement of plasma implantation is that the object is conductive. So it seems difficult to treat the insulating materials. The paper focuses on the possibilities of plasma implantation into insulting materials and presents some examples. (authors)

  10. Influence of different implant materials on the primary stability of orthodontic mini-implants

    OpenAIRE

    Chin-Yun Pan; Szu-Ting Chou; Yu-Chuan Tseng; Yi-Hsin Yang; Chao-Yi Wu; Ting-Hsun Lan; Pao-Hsin Liu; Hong-Po Chang

    2012-01-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants w...

  11. Depresion en pacientes con alteraciones del tiroides

    OpenAIRE

    Radanovic-Grguric´, Ljiljana; Filakovic´, Pavo; Barkic´, Jelena; Mandic´, Nikola; Karner, Ivan; Smoje, Juraj

    2003-01-01

    Nuestro estudio fue realizado en un grupo de 53 mujeres con disfunción tiroidea y 28 mujeres con depresión mayor. Empleamos la Escala de la Depresión de Hamilton, la Escala de Autoevaluación de la Depresión de Zung y la Escala sobre la Impresión Clínica Global. Los resultados del estudio demuestran que la mayoría de los pacientes con disfunción tiroidea se mostraron clínicamente significativos en cuanto al trastorno depresivo. Los episodios depresivos son más frecuentes en pacientes con hipot...

  12. Aprende Ajedrez con Rey - Parte 2

    OpenAIRE

    ESTÉVEZ MONTERO, RAÚL; Lloret Mauri, Jaime

    2016-01-01

    Es una pieza audiovisual creada con el objeto de atraer la atención de los niños de muy corta edad con el ajedrez y familiarizarlos con todas sus piezas y movimientos. Es una animación dirigida a un público infantil presentada por dibujos animados en 2D, en la que se ha intentado respetar en todo momento el argot de la comunidad ajedredística. En este video se presenta la segunda parte. Estévez Montero, R.; Lloret Mauri, J. (2016). Aprende Ajedrez con Rey - Parte 2. http://hdl.handle.net/1...

  13. Aprende Ajedrez con Rey - Parte 1

    OpenAIRE

    ESTÉVEZ MONTERO, RAÚL; Lloret Mauri, Jaime

    2016-01-01

    Es una pieza audiovisual creada con el objeto de atraer la atención de los niños de muy corta edad con el ajedrez y familiarizarlos con todas sus piezas y movimientos. Es una animación dirigida a un público infantil presentada por dibujos animados en 2D, en la que se ha intentado respetar en todo momento el argot de la comunidad ajedredística. En este video se presenta la primera parte. Estévez Montero, R.; Lloret Mauri, J. (2016). Aprende Ajedrez con Rey - Parte 1. http://hdl.handle.net/1...

  14. DESARROLLO AUDITIVO Y LINGUÍSTICO EN NIÑOS CON IMPLANTE COCLEAR

    OpenAIRE

    Fernández-Carrera, Delfina

    2012-01-01

    El presente trabajo trata de comprobar si los cinco alumnos/as implantados pueden lograr un nivel de expresión y comprensión oral similar a los oyentes. Para la muestra se han seleccionado otros cinco alumnos/as del mismo sexo y nivel académico. En dicho estudio, se comprueba que de los cinco alumnos/as implantados, tan sólo uno de ellos logra alcanzar el desarrollo lingüístico correspondiente a su edad cronológica, siendo uno de los factores fundamentales la edad de colocación del impl...

  15. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    OBJECTIVES: The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. MATERIAL AND METHODS: A MEDLINE (PubMed), Embase and Cochrane library search......-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone...... loss around implants with a scalloped implant-abutment connection. CONCLUSIONS: A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must...

  16. [The elementary discussion on digital implant dentistry].

    Science.gov (United States)

    Su, Y C

    2016-04-09

    It is a digital age today. Exposed to all kinds of digital products in many fields. Certainly, implant dentistry is not exception. Digitalization could improve the outcomes and could decrease the complications of implant dentistry. This paper introduces the concepts, definitions, advantages, disadvantages, limitations and errors of digital implant dentistry.

  17. Active implants and scaffolds for tissue regeneration

    CERN Document Server

    Zilberman, Meital

    2011-01-01

    Active implants are actually drug or protein-eluting implants that induce healing effects, in addition to their regular task, such as support. This book gives a broad overview of biomaterial platforms used as basic elements of drug-eluting implants.

  18. Surgical Templates for Dental Implant Positioning; Current ...

    African Journals Online (AJOL)

    Since the mid‑20th century, there has been an increase in interest in the implant process for the replacement of missing teeth. Branemark ... Ideal placement of the implant facilitates the establishment of favorable forces on the implants and the prosthetic component as well as ensures an aesthetic outcome. Therefore, it is ...

  19. The endometrial factor in human embryo implantation

    NARCIS (Netherlands)

    Boomsma, C.M.

    2009-01-01

    The studies presented in this thesis aimed to explore the role of the endometrium in the implantation process. At present, embryo implantation is the major rate-limiting step for success in fertility treatment. Clinicians have sought to develop clinical interventions aimed at enhancing implantation

  20. Macro design morphology of endosseous dental implants.

    Science.gov (United States)

    Sahiwal, Indira G; Woody, Ronald D; Benson, Byron W; Guillen, Guillermo E

    2002-05-01

    The identification of dental implant bodies in patients without available records is a considerable problem due to increased patient mobility and to the large number of implant systems with different designs. The purpose of this study was to document the designs of selected implants to help clinicians identify these implants from their radiographic images. More than 50 implant manufacturers were contacted and asked to provide implants with dimensions as close as possible to 3.75 mm (diameter) x 10 mm (length). Forty-four implants were donated, separated into threaded and non-threaded categories, and further sorted into tapered and non-tapered categories. The implants were examined visually, and features on the entire circumference and length of each implant were recorded and categorized as coronal, midbody, or apical. A series of tables describe the 44 implants according to coronal, midbody, and apical features. The results of this project offer dentists basic knowledge of the design of selected dental implants. Such knowledge can aid the radiographic identification of these implants.

  1. Filosofía, Sociedad y Educación. Con una mirada a España

    Directory of Open Access Journals (Sweden)

    Gómez Ramos, Antonio

    2015-06-01

    Full Text Available Philosophy as a subject might disappear from Spanish secondary education, and its place at the university becomes more and more marginal. Basing on this fact, this article considers the usefulness and uselessness of Philosophy, its connection with democracy and its particular specificity in in the whole of human knowledge. The discussion extends to the relationship between Philosophy and society and its place in higher education, with special consideration to the Spanish case. These conclusions are proposed. 1 Even if it lacks immediate utility, Philosophy always accompanies social flourishing; it fulfills a role that is both critical and integrating. 2 As for the Spanish case, a failure and self-encapsulation of philosophy should be noted, and this cannot be ignore in the reflections and complaints by Spanish philosophers about their current situation. 3 The conception of university with market approaches that is being imposed nowadays is self-contradictory. We must reckon that an institution of higher education aimed to produce knowledge and to preserve social hegemony will exist on. The question is not whether philosophy will have a place there, but how it will perform it. Leaving the question open, some final proposals are made.A partir de la amenaza a la presencia de la Filosofía en la Enseñanza Media, y de su situación cada vez más marginal en la enseñanza universitaria, este artículo plantea una discusión sobre la utilidad o inutilidad de la filosofía, su relación con la democracia y su carácter específico en el conjunto del saber. La discusión se extiende a la relación de la filosofía con la sociedad, y a su lugar en la enseñanza superior, con una consideración especial sobre el caso español. Los resultados que se proponen son: 1 aunque carezca de utilidad inmediata, la filosofía acompaña el florecimiento social, y cumple en él tanto una función crítica como integradora. 2 En el caso español, hay que constatar un

  2. Imaging of common breast implants and implant-related complications: A pictorial essay

    OpenAIRE

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance i...

  3. Primary prevention of peri-implantitis: Managing peri-implant mucositis

    OpenAIRE

    Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; LAMBERT, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni; Schwarz, Frank; Serino, Giovanni

    2015-01-01

    Abstract AIMS: Over the past decades, the placement of dental implants has become a routine procedure in the oral rehabilitation of fully and partially edentulous patients. However, the number of patients/implants affected by peri-implant diseases is increasing. As there are--in contrast to periodontitis--at present no established and predictable concepts for the treatment of peri-implantitis, primary prevention is of key importance. The management of peri-implant mucositis is considere...

  4. Carga diferida en implantología Delayed loading in implantology

    Directory of Open Access Journals (Sweden)

    J.C. de Vicente Rodríguez

    2005-10-01

    Full Text Available La implantología dental se ha convertido en una práctica con bases científicas con el descubrimiento de la biología de la oseointegración. El protocolo terapéutico clásico implicaba mantener los implantes libres de carga hasta que estuviesen oseointegrados. Sin embargo, las desventajas de este procedimiento condujeron posteriormente al desarrollo de un nuevo protocolo, en el que los implantes son cargados de forma inmediata tras su colocación. Sin embargo, este nuevo abordaje suscita dudas acerca de su destino último que aún no han sido resueltas. El objetivo del presente artículo es (i revisar y analizar críticamente las bases biológicas de la carga de los implantes y (ii proponer guías orientativas para elegir el momento ideal de carga de los mismos, en función de variables clínicas. Como conclusión, se establece que si bien las cargas inmediata y diferida proporcionan los mismos resultados en diversas situaciones, la segunda es preferible en presencia de determinados factores de riesgo para el éxito de la primera.Implant dentistry has become a scientifically based practice with the discovery of the biological basis of osseointegration. In the classical protocol, implants were load-free while bone was healing around them to ensure predictable osseointegration. However, several disadvantages of this approach have lead recently to a new protocol based on loading implants immediately after their placement. But, several questions about the outcome of this approach remain unanswered. Therefore, the aim of the present review article is to (i review and analyze critically the biological basis of the load of implants, and (ii propose guidelines for choosing the ideal moment to load dental implants, based on clinical variables. As a conclusion, delayed loading of implants remains the best protocol in several clinical situations.

  5. Cochlear implant after bacterial meningitis.

    Science.gov (United States)

    Bille, Jesper; Ovesen, Therese

    2014-06-01

    The aim of this retrospective case study at a tertiary referral center was to investigate the outcome of cochlear implantation (CI) in children with sensorineural hearing loss due to meningitis compared to CI in children with deafness due to other reasons. This post-meningial group (PMG) consisted of 22 children undergoing CI due to deafness induced by meningitis, between December 1996 and January 2012. Five children had bilateral simultaneous implantation. None was excluded and the children were followed for at least 3 years. Operations were carried out by one of two surgeons using similar techniques in all cases. Each patient from the PMG was matched 2:1 with children having implantation for other reasons according to age and follow up (control group). Overall, the median category of auditory performance (CAP) and speech intelligibility rating (SIR) score were not statistically significantly different between the two groups. The presence of additional central nervous system (CNS) disorders (post-meningeal sequelae), however, correlated significantly with poorer outcome CI was a safe procedure without surgical complications in the present study. It is possible to restore auditory capacity and speech performance to a degree comparable to children undergoing implantation for other reasons. A statistically important variable is secondary CNS involvement. The rehabilitation program after CI should be adjusted according to these additional handicaps. It is recommended to screen meningitis patients as fast as possible to identify those with hearing loss and initiate treatment with hearing aids or CI. © 2013 The Authors. Pediatrics International © 2013 Japan Pediatric Society.

  6. Annealing of ion implanted silicon

    International Nuclear Information System (INIS)

    Chivers, D.; Smith, B.J.; Stephen, J.; Fisher, M.

    1980-09-01

    The newer uses of ion implantation require a higher dose rate. This has led to the introduction of high beam current implanters; the wafers move in front of a stationary beam to give a scanning effect. This can lead to non-uniform heating of the wafer. Variations in the sheet resistance of the layers can be very non-uniform following thermal annealing. Non-uniformity in the effective doping both over a single wafer and from one wafer to another, can affect the usefulness of ion implantation in high dose rate applications. Experiments to determine the extent of non-uniformity in sheet resistance, and to see if it is correlated to the annealing scheme have been carried out. Details of the implantation parameters are given. It was found that best results were obtained when layers were annealed at the maximum possible temperature. For arsenic, phosphorus and antimony layers, improvements were observed up to 1200 0 C and boron up to 950 0 C. Usually, it is best to heat the layer directly to the maximum temperature to produce the most uniform layer; with phosphorus layers however it is better to pre-heat to 1050 0 C. (U.K.)

  7. Implantation of boron in silicon

    International Nuclear Information System (INIS)

    Hofker, W.K.

    1975-01-01

    The distribution versus depth of boron implanted in silicon and the corresponding electrical activity obtained after annealing are studied. The boron distributions are measured by secondary-ion mass spectrometry. Boron distributions implanted at energies in the range from 30 keV to 800 keV in amorphous and polycrystalline silicon are analysed. Moments of these distributions are determined by a curve-fitting programme and compared with moments calculated by Winterbon. Boron distributions obtained by implantations along a dense crystallographic direction in monocrystalline silicon are found to have penetrating tails. After investigation of some possible mechanisms of tail formation it is concluded that the tails are due to channelling. It was found that the behaviour of boron during annealing is determined by the properties of three boron fractions consisting of precipitated boron, interstitial boron and substitutional boron. The electrical activity of the boron versus depth is found to be consistent with the three boron fractions. A peculiar redistribution of boron is found which is induced by the implantation of a high dose of heavy ions and subsequent annealing. Different mechanisms which may cause the observed effects, such as thermal diffusion which is influenced by lattice strain and damage, are discussed. (Auth.)

  8. [Dental implant restoration abutment selection].

    Science.gov (United States)

    Bin, Shi; Hao, Zeng

    2017-04-01

    An increasing number of implant restoration abutment types are produced with the rapid development of dental implantology. Although various abutments can meet different clinical demands, the selection of the appropriate abutment is both difficult and confusing. This article aims to help clinicians select the appropriate abutment by describing abutment design, types, and selection criteria.

  9. Reading skills after cochlear implantation

    NARCIS (Netherlands)

    Vermeulen, A.M.

    2007-01-01

    It has frequently been found that profoundly deaf children with conventional hearing aids have difficulties with the comprehension of written text. Cochlear Implants (CIs) were expected to enhance the reading comprehension of these profoundly deaf children because they provide auditory access to

  10. Advancing Binaural Cochlear Implant Technology

    Directory of Open Access Journals (Sweden)

    Mathias Dietz

    2015-12-01

    Full Text Available This special issue contains a collection of 13 papers highlighting the collaborative research and engineering project entitled Advancing Binaural Cochlear Implant Technology—ABCIT—as well as research spin-offs from the project. In this introductory editorial, a brief history of the project is provided, alongside an overview of the studies.

  11. Cochlear implant: the family's perspective.

    Science.gov (United States)

    Vieira, Sheila de Souza; Dupas, Giselle; Chiari, Brasilia Maria

    2018-07-01

    To understand the family's experience of a child who uses a cochlear implant (CI). Specifically, to identify the difficulties, changes, and feelings entailed by deafness and the use of the CI; the coping strategies; and to understand the role of the family for the child with a CI. Qualitative research, using Symbolic Interactionism and Straussian Grounded Theory as the theoretical and methodological frameworks, respectively. Data collection instrument: semi-structured interview. A total of 9 families (32 individuals) participated in the study. The children's ages ranged from 6 to 11 years old (mean = 8.9 years old). Their experience is described in the following categories: Having to fight for results, Coping with difficult situations, Recognizing that you are not alone, Learning to overcome, and Having one's life restored by the implant. Cochlear implantation changes the direction of the child and the family's life by restoring the child's opportunity to hear and to obtain good results in her personal, social, and academic development. Even after implantation, the child continues to experience difficulties and requires the family's mobilization in order to be successful. The family is the principal actor in the process of the child's rehabilitation.

  12. Usher syndrome and cochlear implantation.

    Science.gov (United States)

    Loundon, Natalie; Marlin, Sandrine; Busquet, Denise; Denoyelle, Françoise; Roger, Gilles; Renaud, Francis; Garabedian, Erea Noel

    2003-03-01

    To evaluate the symptoms leading to diagnosis and the quality of rehabilitation after cochlear implantation in Usher syndrome. Retrospective cohort study. ENT department of a tertiary referral hospital. Among 210 patients given an implantation in the Ear, Nose, and Throat department, 185 were congenitally deaf and 13 had Usher syndrome (7.0%). Five had a family history of Usher, and eight were sporadic cases. Eleven cases were Usher type I, one was Usher type III, and one was not classified. The age at implantation ranged from 18 months to 44 years (mean, 6 years 1 month). The mean follow-up was 52 months (range, 9 months to 9 years). All patients had audiophonological and clinical examination, computed tomography scan of the temporal bones, ophthalmologic examination with fundoscopy, and an electroretinogram. Cerebral magnetic resonance imaging and vestibular examination were performed in 9 of 13 and 10 of 13 cases, respectively. Logopedic outcome measured preimplant and postimplant closed- and open-set word recognition and oral expression at follow-up. The most frequent initial sign of Usher syndrome was delayed walking, with a mean age of 20 months. Among the 172 other congenitally deaf children with implants, when deafness was not associated with other neurologic disorders, the mean age at walking was 14 months (p < 0.001). The fundoscopy was always abnormal after the age of 5 years, and the electroretinogram was abnormal in all cases. Vestibular function was abnormal in all but one case (nonclassified). The computed tomography scan and the magnetic resonance imaging were always normal. Logopedic results with cochlear implants showed good perception skills in all but one case. The best perceptive results were obtained in children implanted before the age of 9 years. Oral language had significantly progressed in 9 of 13 at follow-up. There was no relation between the visual acuity and the logopedic results. The earliest clinical sign associated with deafness

  13. Failure analysis of fractured dental zirconia implants.

    Science.gov (United States)

    Gahlert, M; Burtscher, D; Grunert, I; Kniha, H; Steinhauser, E

    2012-03-01

    The purpose of the present study was the macroscopic and microscopic failure analysis of fractured zirconia dental implants. Thirteen fractured one-piece zirconia implants (Z-Look3) out of 170 inserted implants with an average in situ period of 36.75±5.34 months (range from 20 to 56 months, median 38 months) were prepared for macroscopic and microscopic (scanning electron microscopy [SEM]) failure analysis. These 170 implants were inserted in 79 patients. The patient histories were compared with fracture incidences to identify the reasons for the failure of the implants. Twelve of these fractured implants had a diameter of 3.25 mm and one implant had a diameter of 4 mm. All fractured implants were located in the anterior side of the maxilla and mandibula. The patient with the fracture of the 4 mm diameter implant was adversely affected by strong bruxism. By failure analysis (SEM), it could be demonstrated that in all cases, mechanical overloading caused the fracture of the implants. Inhomogeneities and internal defects of the ceramic material could be excluded, but notches and scratches due to sandblasting of the surface led to local stress concentrations that led to the mentioned mechanical overloading by bending loads. The present study identified a fracture rate of nearly 10% within a follow-up period of 36.75 months after prosthetic loading. Ninety-two per cent of the fractured implants were so-called diameter reduced implants (diameter 3.25 mm). These diameter reduced implants cannot be recommended for further clinical use. Improvement of the ceramic material and modification of the implant geometry has to be carried out to reduce the failure rate of small-sized ceramic implants. Nevertheless, due to the lack of appropriate laboratory testing, only clinical studies will demonstrate clearly whether and how far the failure rate can be reduced. © 2011 John Wiley & Sons A/S.

  14. Effectiveness of Implant Therapy Analyzed in a Swedish Population: Prevalence of Peri-implantitis.

    Science.gov (United States)

    Derks, J; Schaller, D; Håkansson, J; Wennström, J L; Tomasi, C; Berglundh, T

    2016-01-01

    Peri-implantitis is an inflammatory disease affecting soft and hard tissues surrounding dental implants. As the global number of individuals that undergo restorative therapy through dental implants increases, peri-implantitis is considered as a major and growing problem in dentistry. A randomly selected sample of 588 patients who all had received implant-supported therapy 9 y earlier was clinically and radiographically examined. Prevalence of peri-implantitis was assessed and risk indicators were identified by multilevel regression analysis. Forty-five percent of all patients presented with peri-implantitis (bleeding on probing/suppuration and bone loss >0.5 mm). Moderate/severe peri-implantitis (bleeding on probing/suppuration and bone loss >2 mm) was diagnosed in 14.5%. Patients with periodontitis and with ≥4 implants, as well as implants of certain brands and prosthetic therapy delivered by general practitioners, exhibited higher odds ratios for moderate/severe peri-implantitis. Similarly, higher odds ratios were identified for implants installed in the mandible and with crown restoration margins positioned ≤1.5 mm from the crestal bone at baseline. It is suggested that peri-implantitis is a common condition and that several patient- and implant-related factors influence the risk for moderate/severe peri-implantitis (ClinicalTrials.gov NCT01825772). © International & American Associations for Dental Research 2015.

  15. Plantas cubanas con efecto antiinflamatorio

    Directory of Open Access Journals (Sweden)

    Ada Ivis Regalado Veloz

    Full Text Available La actividad antiinflamatoria suscita gran interés científico en el área farmacológica, debido a que muchas enfermedades en su evolución cursan por procesos inflamatorios (artritis reumatoide, ateroesclerosis, cáncer, diabetes, gota, asma, dermatitis, trastornos neurodegenerativos y diversas dolencias menores. Las enfermedades inflamatorias constituyen un problema de salud importante, debido a la falta de medicamentos eficaces y seguros para su uso por periodos prolongados. Hoy en día se trabaja en la búsqueda de alternativas de antiinflamatorios más seguros, en el que las plantas medicinales, una de las formas más antiguas de tratamiento, constituyen una elección a considerar. En este trabajo se realizó una revisión bibliográfica, sobre especies de plantas que crecen en Cuba que le reportan propiedades farmacológicas como antinflamatorios. En la revisión de la literatura se utilizó la base de datos Medline (vía PubMed, así como revistas nacionales desde el periodo de 2000 hasta el presente, con las palabras claves "inflamación" y "plantas cubanas antiinflamatorias" o "actividad antiinflamatoria" y "plantas medicinales".

  16. Hospitalidad, con y sin papeles

    Directory of Open Access Journals (Sweden)

    Ana Paula Penchaszadeh

    Full Text Available Resumen El objetivo de este artículo es vincular el trabajo sobre el archivo de Jacques Derrida con la experiencia de la hospitalidad. Se intentará mostrar que, por un lado, se trata siempre de los papeles, de la legitimidad que éstos otorgan o no tanto a nivel filosófico (deseo de poseer los papeles que autoricen tal o cual decisión interpretativa, como a nivel político ("tener papeles" como el principio básico de todo derecho a tener derechos, de todo derecho a la comunidad. Mas también, por otro lado, se intentará pensar aquello que arruina la idea misma de tener o no tener (papeles, la idea de propiedad, aquello que hace imposible fundar una decisión o identidad en última instancia y, por ende, una soberanía, una frontera. La hospitalidad, la llegada inminente del otro, representa un desafío político y ético para la filosofía: pues no se trata de un saber, sino de una experiencia transformando el sustrato del nos-otros, del ser común.

  17. Itinerari Musicali con la Wiild

    Directory of Open Access Journals (Sweden)

    Elisabetta Nanni

    2013-03-01

    Full Text Available La Wiild, acronimo di Wiimote Lavagna Digitale, è uno strumento didattico che utilizza il telecomando della Wii, il famoso gioco della Nintendo, insieme a un software libero, rendendolo così estremamente versatile. Non vincolato a software proprietario, il suo utilizzo è legato alla capacità dell’insegnante di ripartire dalla didattica, dalle risorse selezionate e dall’epistemologia di ogni singola disciplina, trovando così nel proprio contesto un ruolo per le tecnologie. Il contributo presenta ipotesi di lavoro per l’educazione musicale nella scuola secondaria di primo grado che si sviluppano sia attraverso lo studio del rapporto suono/segno con affinità pittoriche e successiva codificazione grafica, sia attraverso un’attività di laboratorio in cui co-costruire percorsi storico-musicali. La Wiild diventerà davvero utile ed efficace nel momento in cui, affiancando le risorse selezionate dal docente, verrà utilizzata senza essere notata, giocando un ruolo di strumento tecnologico «normale e trasparente».

  18. He reemission implanted in metals

    International Nuclear Information System (INIS)

    Tanabe, T.

    2014-01-01

    Highlights: • Observation of He reemission of various metals under He + implantation at wide temperature range. • Materials examined are aluminum (Al), Nickel (Ni) and molybdenum (Mo). • He reemission is quite temperature dependent and different with materials. • Three metals show similar dependence on temperature normalized with respective melting point. • He reemission is successfully correlated with He behavior in metals. - Abstract: Helium (He) reemission of Al, Ni and Mo under energetic He implantation (10–30 keV) in wide temperature range is studied to understand behavior of implanted He in correlation with structure changes. The reemission behavior is categorized into 4 different temperature ranges with the normalized temperature (T m ) to the melting point of each metal. At elevated temperatures (well above ∼0.6 T m ), interstitial He atoms and/or He-vacancy (ies) clusters can migrate remaining no structure change and showing smooth reemission without any burst. Between ∼0.25 and 0.6 T m , He reemission always accompanies significant structure modification. For ∼04–0.6 T m , implanted He coalesce to make bubbles and the bubbles can move to the surface. Bubble migration accompanies materials flow to the surface resulting in fuzz surface or columnar structure, depending on implantation flux. Slower bubble motion at ∼0.25–0.4 prohibits the material migration. Instead the bubbles coalesce to grow large and multi-layered blistering appears as periodic reemission behavior. Below ∼0.25 T m , He migration is too slow for bubbles to grow large, but bubble density increases up to a certain fluence, where neighboring bubbles start to coalesce. Accordingly, He release is mostly caused by mechanical failure or blister rapture. With increasing fluence, all defects (bubbles and dislocation loops) tangle or inter connected with neighboring defects and accordingly He migration to the surface along the tangled or connected defects is enhanced

  19. [Cochlear implant treatment in Germany].

    Science.gov (United States)

    Jacob, R; Stelzig, Y

    2013-01-01

    Restoration of impaired auditory function through cochlear implant is possible, with high reliably and great success. Nevertheless, there are regular disputes between patients and insurance companies due to high costs. In Germany, approx. 1.9 Mio. people are severely hearing impaired. It can be estimated that for adequate hearing rehabilitation about 30,000 cochlear implants/year are necessary. Currently, less than 10% of those affected are offered cochlear implant. A handicap is defined if there is deviation from normal hearing for more than 6 months. This sets a time frame for the supply with cochlear implant after sudden deafness. The professional code requires to advice all medical options to a person seeking help for hearing loss. This includes benefit-risk consideration. At this point, the economic aspect plays no role. The indication for medical treatment is only subject to the treating physician and should not be modified by non-physicians or organizations. It should be noted that a supply of hearing aids is qualitatively different to the help from a cochlear implant, which provides a restoration of lost function. In social law (SGB V and IX) doctors are requested to advise and recommend all measures which contribute to normal hearing (both sides). This indicates that doctors may be prosecuted for not offering help when medically possible, just because health insurance employees did not approve the cost balance. The current situation, with insufficient medical care for the hearing impaired, needs clarifying. To do this, patients, health insurance companies, the political institutions, legislation and professional societies need to accept their responsibilities.

  20. Peri-implant esthetics assessment and management

    Science.gov (United States)

    Balasubramaniam, Aarthi S.; Raja, Sunitha V.; Thomas, Libby John

    2013-01-01

    Providing an esthetic restoration in the anterior region of the mouth has been the basis of peri-implant esthetics. To achieve optimal esthetics, in implant supported restorations, various patient and tooth related factors have to be taken into consideration. Peri-implant plastic surgery has been adopted to improve the soft tissue and hard tissue profiles, during and after implant placement. The various factors and the procedures related to enhancement of peri-implant esthetics have been discussed in this review article. PMID:23878557

  1. Structural-chemical characteristics of implanted metals

    International Nuclear Information System (INIS)

    Kozejkin, B.V.; Pavlov, P.V.; Pitirimova, E.A.; Frolov, A.I.

    1988-01-01

    Corrosion and structural characteristics of metallic layers implanted by ions of chemically active impurities and noble gases are studied. Dependence of experimental results on parameters of initial materials and technological conditions of implantation is established. In studying corrosion characteristics of implanted metals a strong dependence of chemical passivation effect on technological conditions of ion-implantation and structure of initial material is stated. On the basis of developed mathematical model of chemical passivation effect it is shown that increase of corrosion characteristics of implanted metals is defined by superposition of surface and volumetric mechanisms

  2. Current Concepts in Restorative Implant Dentistry

    Institute of Scientific and Technical Information of China (English)

    Prof.Marchack

    2009-01-01

    Patients today are incteasingly aware of dental implants.and their expectations are for esthetically and functionally pleasingimplant restorations that mimic natural teeth.This presentation will give both the experienced and novice practitioner a better understand-ing of how restorative implant dentistry has evolved.Treatment planning and restorative options for single implants.multiple implants andfully edentulons arches will be discussed,and the use of modern materials and CADCAM technology in fabricating the most contemporaryfixed implant supported prostheses will be demonstrated.

  3. Implante ExPRESS-P en el glaucoma traumático

    Directory of Open Access Journals (Sweden)

    Francisco Fumero González

    Full Text Available Se presenta un paciente masculino, blanco, de 32 años de edad, con antecedentes de trauma contuso en el ojo izquierdo a los 8 años de edad. El examen oftalmológico del ojo izquierdo reveló agudeza visual mejor corregida 60 VAR; presión intraocular 42 mmHg con terapia hipotensora máxima; catarata corticonuclear traumática y daño glaucomatoso avanzado. Como opción de tratamiento se realizó la cirugía combinada (facoemulsificación e implante de dispositivo ExPRESS, modelo P-50, asociado al uso de mitomicina C 0,2 %. Se obtuvo agudeza visual mejor corregida 97 VAR y presión intraocular 17 mmHg a los 3 meses posoperatorio. Este caso evidencia la necesidad del seguimiento de por vida luego de un trauma ocular, y fundamentalmente cuando existe un receso angular traumático, con la finalidad de diagnosticar precozmente la hipertensión ocular y prevenir la pérdida visual irreversible por glaucoma. La facoemulsificación combinada con el implante ExPRESS resulta una opción favorable para el tratamiento de casos complejos que presentan glaucoma y catarata.

  4. Bases tratadas con cemento, en California

    Directory of Open Access Journals (Sweden)

    Chinchilla, M.

    1962-05-01

    Full Text Available El uso de bases tratadas con cemento para autopistas se inició en el Estado de California en 1938, empleándose para carreteras con determinadas condiciones de tráfico. Inicialmente, se especificó el uso obligatorio de plantas mezcladoras para asegurar el debido control de las proporciones adecuadas.

  5. Novedoso separador con diodo ultrabrillante New retractor with ultrabilliant diode

    Directory of Open Access Journals (Sweden)

    M. Bernstein

    2008-06-01

    Full Text Available Presentamos un separador quirúrgico innovador por su comodidad y potente iluminación que consideramos ideal para la cirugía de colocación de implantes mamarios, si bien, puede utilizarse también para facilitar otras cirugía en cavidades de difícil acceso. Tras diferentes estudios y pruebas hemos logrado un diseño que se diferencia de otros en que, al no ser plano y tener una menor superficie de contacto, produce menor lesión de los tejidos y permite una mejor visualización del campo operatorio, de manera que podemos observar sangrados que a veces quedan ocultos con los separadores planos comunes. Su novedosa iluminación es pequeña, potente y precisa, sin necesidad de fuente generadora de luz externa ni de incómodos cables de fibra óptica, lo que lo hace de fácil manipulación y transporte.After many studies and tests a very innovative, strong and comfortable retractor is introduced; it is considered ideal for mammary implants surgery and it is also very useful in difficult access surgeries. This new design produces less tissue damage than ordinary flat retractors due to its smaller contact surface; besides it allows a better view of the surgery field (as it permits the observation of any bleeding that traditional flat separators would hide. Its modern illumination is strong and precise; it offers above 25% more light than fiber optics without any external light source what makes this retractor very easy to handle and to transport.

  6. Poly Implants Prosthèse Breast Implants: A Case Series and Review of the Literature.

    Science.gov (United States)

    Klein, Doron; Hadad, Eran; Wiser, Itay; Wolf, Omer; Itzhaki Shapira, Ortal; Fucks, Shir; Heller, Lior

    2018-01-01

    Silicone breast implants from the French manufacturer Poly Implants Prosthèse (PIP) were recalled from the European market after the French regulator has revealed the implants contain non-medical-grade silicone filler. In December 2011, following a large increase in reported rupture rate and a possible cancer risk, the French Ministry of Health recommended consideration of the PIP explantation, regardless of their condition. In 2012, the Israel Ministry of Health recommended to replace the implants only upon suspected implant rupture. The aims of this study were to characterize breast-augmented Israeli patients with PIP implants, compare their outcomes with those of breast-augmented patients with different implant types, and review the current PIP literature. Breast-augmented patients who underwent an elective breast implant exchange in Israel between January 2011 and January 2017 were included in the study. Data were collected from electronic and physical medical files. There were 73 breast-augmented female patients with 146 PIP breast implants included in this study. Average implant age was 6.7 ± 2.79 years. Mean implant size was 342.8 ± 52.9 mL. Fourteen women (19 implants [16%]) had a high-grade capsular contracture (Baker grade 3-4). During exchange, 28 implants were found to be ruptured (19.2%). Less than 10 years following breast augmentation, PIP implants demonstrated higher rupture rate compared with other implants. Our data are comparable to overall available rupture rate. Among patients with definitive rupture diagnosis, an elective implant removal should be recommended. In cases of undamaged implants, plastic surgeons should also seriously consider PIP implant explantation. When the patient does not desire to remove the implant, an annual physical examination and breast ultrasound are recommended, beginning a year after augmentation.

  7. [Clinical application of individualized three-dimensional printing implant template in multi-tooth dental implantation].

    Science.gov (United States)

    Wang, Lie; Chen, Zhi-Yuan; Liu, Rong; Zeng, Hao

    2017-08-01

    To study the value and satisfaction of three-dimensional printing implant template and conventional implant template in multi-tooth dental implantation. Thirty cases (83 teeth) with missing teeth needing to be implanted were randomly divided into conventional implant template group (CIT group, 15 cases, 42 teeth) and 3D printing implant template group (TDPIT group, 15 cases, 41 teeth). Patients in CIT group were operated by using conventional implant template, while patients in TDPIT group were operated by using three-dimensional printing implant template. The differences of implant neck and tip deviation, implant angle deviation and angle satisfaction between the two groups were compared. The difference of probing depth and bone resorption of implant were compared 1 year after operation between the two groups. The difference of success rate and satisfaction of dental implantation were compared 1 year after operation between the two groups. SPSS19.0 software package was used for statistical analysis. The deviation direction of the neck and the tip in disto-mesial, bucco-palatal, vertical direction and angle of implants in disto-mesial and bucco-palatal direction in TDPIT group were significantly lower than in CIT group (P0.05). The difference of the cumulative success rate in dental implantation at 3 months and 6 months between the two groups were not significant (P>0.05), but the cumulative success rate of TDPIT group was significantly higher than CIT group at 9 months and 1 year (90.48% vs 100%,P=0.043). The patients' satisfaction rate of dental implantation in TDPIT group was significantly higher than in CIT group (86.67% vs 53.33%, P=0.046). Using three-dimensional printing implant template can obtain better accuracy of implant, higher implant success rate and better patients' satisfaction than using conventional implant template. It is suitable for clinical application.

  8. Osseoconductive and Corrosion-Inhibiting Plasma-Sprayed Calcium Phosphate Coatings for Metallic Medical Implants

    Directory of Open Access Journals (Sweden)

    Robert B. Heimann

    2017-11-01

    Full Text Available During the last several decades, research into bioceramic coatings for medical implants has emerged as a hot topic among materials scientists and clinical practitioners alike. In particular, today, calcium phosphate-based bioceramic materials are ubiquitously used in clinical applications to coat the stems of metallic endoprosthetic hips as well as the surfaces of dental root implants. Such implants frequently consist of titanium alloys, CoCrMo alloy, or austenitic surgical stainless steels, and aim at replacing lost body parts or restoring functions to diseased or damaged tissues of the human body. In addition, besides such inherently corrosion-resistant metals, increasingly, biodegradable metals such as magnesium alloys are being researched for osseosynthetic devices and coronary stents both of which are intended to remain in the human body for only a short time. Biocompatible coatings provide not only vital biological functions by supporting osseoconductivity but may serve also to protect the metallic parts of implants from corrosion in the aggressive metabolic environment. Moreover, the essential properties of hydroxylapatite-based bioceramic coatings including their in vitro alteration in contact with simulated body fluids will be addressed in this current review paper. In addition, a paradigmatic shift is suggested towards the development of transition metal-substituted calcium hexa-orthophosphates with the NaSiCON (Na superionic conductor structure to be used for implant coatings with superior degradation resistance in the corrosive body environment and with pronounced ionic conductivity that might be utilized in novel devices for electrical bone growth stimulation.

  9. Metodología para la manufactura de implantes craneales a partir de imágenes DICOM y tecnologías CAD/CAM/CNC Metodología para la manufactura de implantes craneales a partir de imágenes DICOM y tecnologías CAD/CAM/CNC

    Directory of Open Access Journals (Sweden)

    Iván López

    2005-12-01

    Full Text Available El presente artículo propone una metodología para el diseño y la fabricación de implantes craneales a partir de imágenes DICOM y tecnologías CAD/CAM/CNC. Esta metodología parte de las Tomografías Axiales Computarizadas (TAC de la cabeza del paciente, con las cuales se lleva a cabo la reconstrucción tridimensional del cráneo. Luego, en el sistema CAD se reconstruye el implante variando la técnica empleada dependiendo de la región del cráneo con defecto o trauma. Una vez obtenido el modelo, se diseña el montaje y se fabrica el implante con soporte en tecnología CAM/CNC.It’s proposed a methodology in order to design and manufacture cranial implants using DICOM and CAD/CAM/CNC technologies. This methodology begins when the designer makes a three-dimensional cranial reconstruction using the Axial Computer Tomographies (ACT of the patient’s cranium. Next, using a CAD system, the designer rebuilds the implant varying the used technique depending on the affected region. Finally, the designer builds the assembling and manufactures the implant.

  10. Ion implantation and bio-compatibility

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Yoshiaki; Kusakabe, Masahiro [Sony Corp., Tokyo (Japan). Corporate Research Labs.; Iwaki, Masaya

    1992-07-01

    Surface modification of polymers by ion implantation has been carried out to control surface properties such as conductivity, wettability, blood and tissue compatibility. Ion implantation into silicone rubber, polystyrene and segmented polyurethane was performed at 150 keV with doses ranging from 1 x 10[sup 15] to 3 x 10[sup 17] ions/cm[sup 2] to improve bio-compatibility. The platelet accumulation on ion implanted silicone rubber decreased and non-thrombogenicity of ion implanted specimens were improved. The ion implanted polystyrene and segmented polyurethane have been found to exhibit remarkably higher adhesion and spreading of endothelial cells compared to the non-implanted case. It is concluded that ion implantation into polymers is effective in controlling their bio-compatibility. (author).

  11. Congenitally Deafblind Children and Cochlear Implants

    DEFF Research Database (Denmark)

    Dammeyer, Jesper Herup

    2008-01-01

    There has been much research conducted demonstrating the positive benefits of cochlear implantation (CI) in children who are deaf. Research on cochlear implantation in children who are both deaf and blind, however, is lacking. The purpose of this article is to present a study of 5 congenitally...... deafblind children who received cochlear implants between 2.2 and 4.2 years of age.  Ratings of video observations were used to measure the children's early communication development with and without the use of their cochlear implants. In addition, parental interviews were used to assess the benefits...... parents perceived regarding their children's cochlear implants. Two examples are included in this article to illustrate the parents' perspectives about cochlear implantation in their deafblind children. Benefits of cochlear implantation in this cohort of children included improved attention and emotional...

  12. Dynamics of bone graft healing around implants

    Directory of Open Access Journals (Sweden)

    Narayan Venkataraman

    2015-01-01

    A few questions arise pertaining to the use of bone grafts along with implants are whether these are successful in approximation with implant. Do they accelerate bone regeneration? Are all defects ultimately regenerated with new viable bone? Is the bone graft completely resorbed or integrated in new bone? Does the implant surface characteristic positively affect osseointegration when used with a bone graft? What type of graft and implant surface can be used that will have a positive effect on the healing type and time? Finally, what are the dynamics of bone graft healing around an implant? This review discusses the cellular and molecular mechanisms of bone graft healing in general and in vicinity of another foreign, avascular body, namely the implant surface, and further, the role of bone grafts in osseointegration and/or clinical success of the implants.

  13. Magnetic resonance imaging of breast implants.

    Science.gov (United States)

    Shah, Mala; Tanna, Neil; Margolies, Laurie

    2014-12-01

    Silicone breast implants have significantly evolved since their introduction half a century ago, yet implant rupture remains a common and expected complication, especially in patients with earlier-generation implants. Magnetic resonance imaging is the primary modality for assessing the integrity of silicone implants and has excellent sensitivity and specificity, and the Food and Drug Administration currently recommends periodic magnetic resonance imaging screening for silent silicone breast implant rupture. Familiarity with the types of silicone implants and potential complications is essential for the radiologist. Signs of intracapsular rupture include the noose, droplet, subcapsular line, and linguine signs. Signs of extracapsular rupture include herniation of silicone with a capsular defect and extruded silicone material. Specific sequences including water and silicone suppression are essential for distinguishing rupture from other pathologies and artifacts. Magnetic resonance imaging provides valuable information about the integrity of silicone implants and associated complications.

  14. Surface modification of implants in long bone.

    Science.gov (United States)

    Förster, Yvonne; Rentsch, Claudia; Schneiders, Wolfgang; Bernhardt, Ricardo; Simon, Jan C; Worch, Hartmut; Rammelt, Stefan

    2012-01-01

    Coatings of orthopedic implants are investigated to improve the osteoinductive and osteoconductive properties of the implant surfaces and thus to enhance periimplant bone formation. By applying coatings that mimic the extracellular matrix a favorable environment for osteoblasts, osteoclasts and their progenitor cells is provided to promote early and strong fixation of implants. It is known that the early bone ongrowth increases primary implant fixation and reduces the risk of implant failure. This review presents an overview of coating titanium and hydroxyapatite implants with components of the extracellular matrix like collagen type I, chondroitin sulfate and RGD peptide in different small and large animal models. The influence of these components on cells, the inflammation process, new bone formation and bone/implant contact is summarized.

  15. Fuerza manual de adultos con discapacidad intelectual

    Directory of Open Access Journals (Sweden)

    Ruth Cabeza Ruiz

    2017-09-01

    Full Text Available Objetivo. Presentar una descripción de la fuerza de prensión manual de hombres y mujeres con discapacidad intelectual (DI y comparar los resultados con valores de referencia de otras personas con y sin discapacidad intelectual. Método. El presente trabajo es un estudio transversal observacional, financiado por la Fundación SAMU, en el que se evaluaron a 122 personas con DI (86 hombres y 36 mujeres durante el desarrollo de unas jornadas de carácter recreativo en las que participaron varias asociaciones de atención a este colectivo. La batería de test utilizada fue el Alpaha-Fit Test Battery for Adults. Resultados. Se presentan los resultados relacionados con las variables de fuerza del miembro superior (Hand Grip Strength por grupos de edad (20-24, 25- 29, 30-34, 35-39, 40-44, 45-49, 50-54, 55-59 años. Los datos muestran valores que oscilan desde los 31 kg en los hombres más jóvenes con DI hasta los 13.3 kg del grupo más maduro de mujeres. Estos hallazgos son similares a los valores de referencia de población con DI española. Sin embargo, son muy inferiores a los obtenidos por la población sin discapacidad de la misma edad. Conclusión. Los resultados evidencian el menor rendimiento de las personas con DI en pruebas de fuerza de prensión manual por lo que se hace evidente la necesidad de llevar a cabo programas de ejercicio físico o deporte con las personas con DI.

  16. Esclerosis sistémica complicada con síncope y bloqueo AV completo

    Directory of Open Access Journals (Sweden)

    Francisco Femenía

    2010-10-01

    Full Text Available La esclerosis sistémica es una compleja enfermedad que afecta el tejido conectivo, el sistema vascular y el sistema inmunológico, y se caracteriza por fibrosis cutánea y de órganos viscerales. Los bloqueos de rama y los hemibloqueos se presentan en el 25 a 75% de los casos y constituyen predictores independientes de mortalidad. Los bloqueos auriculoventriculares de segundo o tercer grado son muy raros. Presentamos el caso de una mujer de 47 años de edad, con diagnóstico de esclerosis sistémica, quien presenta episodio sincopal secundario a bloqueo auriculoventricular completo con necesidad de implante de marcapasos definitivo.

  17. Successful Rehabilitation of Partial Edentulous Maxilla and Mandible with New Type of Implants: Molecular Precision Implants

    Directory of Open Access Journals (Sweden)

    Matteo Danza

    2014-01-01

    Full Text Available The extraction of teeth results in rapid bone resorption both vertically and horizontally in the first month. The loss of alveolar ridge reduces the chance of implant rehabilitation. Atraumatic extraction, implant placement in extraction socket, and an immediate prosthesis have been proposed as alternative therapies to maintain the volume and contours tissue and reduce time and cost of treatment. The immediate load of implants is a universally practiced procedure; nevertheless a successful procedure requires expertise in both the clinical and the reconstructive stages using a solid implant system. Excellent primary stability and high bone-implant contact are only minimal requirements for any type of implant procedure. In this paper we present a case report using a new type of implants. The new type of implants, due to its sophisticated control system of production, provides to the implantologist a safe and reliable implant, with a macromorphology designed to ensure a close contact with the surrounding bone.

  18. Miocarditis de células gigantes con bloqueo AV completo persistente: respuesta al tratamiento con resincronizador cardiaco Giant cell myocarditis with complete persistent A-V block: treatment response with cardiac resynchronization

    Directory of Open Access Journals (Sweden)

    Julián Aristizábal

    2009-08-01

    Full Text Available La miocarditis de células gigantes es una enfermedad grave y poco frecuente, cuya etiología, posiblemente autoinmune, se caracteriza por la presencia de células gigantes multinucleadas con infiltrado inflamatorio y necrosis extensa en la biopsia endomiocárdica. Es común su asociación con taquicardias ventriculares y con alteraciones de la conducción aurículo-ventricular, lo cual se resuelve algunas veces con tratamiento inmunosupresor. Dada la complejidad del pronóstico de esta entidad, el papel de los dispositivos de resincronización después de la estabilización de la falla cardíaca, no está claro. Aquí se reporta un caso en el cual el implante de uno de estos dispositivos fue parte fundamental de la terapia y recuperación del paciente.Giant cell myocarditis is an infrequent and serious illness, possibly of autoimmune etiology, characterized by the presence of multinucleated giant cells with inflammatory infiltrate and extensive necrosis in the endomyocardial biopsy. Its association with ventricular tachycardia is common and alterations in atrioventricular conduction are frequently solved through immunosuppressive treatment. Given the generally complex prognosis of this entity, the role of the resynchronization devices after the heart failure stabilization, is unclear. We reported a case in which the implant of one of these devices was a fundamental part of the therapy and patient recovery.

  19. Does the number of implants have any relation with peri-implant disease?

    Directory of Open Access Journals (Sweden)

    Bernardo Born PASSONI

    2014-10-01

    Full Text Available Objective: The aim of this study was to evaluate the relationship between the number of pillar implants of implant-supported fixed prostheses and the prevalence of periimplant disease. Material and Methods: Clinical and radiographic data were obtained for the evaluation. The sample consisted of 32 patients with implant-supported fixed prostheses in function for at least one year. A total of 161 implants were evaluated. Two groups were formed according to the number of implants: G1 ≤5 implants and G2 >5 implants. Data collection included modified plaque index (MPi, bleeding on probing (BOP, probing depth (PD, width of keratinized mucosa (KM and radiographic bone loss (BL. Clinical and radiographic data were grouped for each implant in order to conduct the diagnosis of mucositis or peri-implantitis. Results: Clinical parameters were compared between groups using Student’s t test for numeric variables (KM, PD and BL and Mann-Whitney test for categorical variables (MPi and BOP. KM and BL showed statistically significant differences between both groups (p<0.001. Implants from G1 – 19 (20.43% – compared with G2 – 26 (38.24% – showed statistically significant differences regarding the prevalence of peri-implantitis (p=0.0210. Conclusion: It seems that more than 5 implants in total fixed rehabilitations increase bone loss and consequently the prevalence of implants with periimplantitis. Notwithstanding, the number of implants does not have any influence on the prevalence of mucositis.

  20. Comparative silicone breast implant evaluation using mammography, sonography, and magnetic resonance imaging: experience with 59 implants.

    Science.gov (United States)

    Ahn, C Y; DeBruhl, N D; Gorczyca, D P; Shaw, W W; Bassett, L W

    1994-10-01

    With the current controversy regarding the safety of silicone implants, the detection and evaluation of implant rupture are causing concern for both plastic surgeons and patients. Our study obtained comparative value analysis of mammography, sonography, and magnetic resonance imaging (MRI) in the detection of silicone implant rupture. Twenty-nine symptomatic patients (total of 59 silicone implants) were entered into the study. Intraoperative findings revealed 21 ruptured implants (36 percent). During physical examination, a positive "squeeze test" was highly suggestive of implant rupture. Mammograms were obtained of 51 implants (sensitivity 11 percent, specificity 89 percent). Sonography was performed on 57 implants (sensitivity 70 percent, specificity 92 percent). MRI was performed on 55 implants (sensitivity 81 percent, specificity 92 percent). Sonographically, implant rupture is demonstrated by the "stepladder sign." Double-lumen implants may appear as false-positive results for rupture on sonography. On MRI, the "linguine sign" represents disrupted fragments of a ruptured implant. The most reliable imaging modality for implant rupture detection is MRI, followed by sonogram. Mammogram is the least reliable. Our study supports the clinical indication and diagnostic value of sonogram and MRI in the evaluation of symptomatic breast implant patients.

  1. Análisis del proceso de urgencias y hospitalización del CAMI Diana Tubay a través de un modelo de simulación con Arena 10.0 para la distribución óptima del recurso humano

    Directory of Open Access Journals (Sweden)

    Liliana Maria Pantoja Rojas

    2008-01-01

    Full Text Available Este documento presenta un modelo de simulación que describe el procedimiento actual de Atención del Área de Urgencias y Hospitalización del Centro de Atención Médica Inmediata (CAMI DIANA TURBAY, Entidad Prestadora de Salud de Primer Nivel de carácter oficial en la ciudad de Bogotá. En el proceso se elaboró una síntesis de estu-dio y registro global de las actividades en las condiciones actuales de atención en el área de Urgencias y Hospitali-zación, así como propuestas que permitieran mejorar las condiciones de atención a los pacientes y que ayudaran a optimizar los recursos con los que dispone la institución en el área mencionada. Lo anterior se obtuvo contrastando los tiempos de espera, personas en cola y utilización del personal, con la propuesta de estructuración del proce-dimiento del triage presentado por la oficina de Gestión Pública y Autocontrol del Hospital Rafael Uribe Uribe y cu-yo procedimiento se desea implementar en el marco del proyecto de remodelación y ampliación del CAMI. Tam-bién se ensayan diferentes escenarios para evaluar la factibilidad en la reducción de tiempos de espera y número de personas en cola, probando diferentes alternativas de horarios y disposición de recursos de apoyo, con lo cual se muestra una reducción sustancial en los tiempos de atención y de espera de los pacientes.

  2. Experiencias de haber crecido con un padre/madre con trastorno mental severo (TMS)

    OpenAIRE

    Vivanco B, Gabriela; Grandón F, Pamela

    2016-01-01

    Introducción. La experiencia de vivir con personas que presentan un Trastorno Mental Severo (TMS) es difícil para las familias, en especial para los hijos quienes han sido poco estudiados. El objetivo de la investigación fue conocer cómo la experiencia de haber vivido con un padre o madre con un trastorno mental severo influyó en la infancia, adolescencia y adultez joven de sus hijos e hijas. Método. Se analizan las experiencias de convivencia con un padre/madre con TMS en 10 hijos (6 hombres...

  3. Implante coclear en enfermedad de Ménière bilateral. Descripción de un caso

    Directory of Open Access Journals (Sweden)

    Ainhoa MORENO-BRAVO

    2017-03-01

    Full Text Available Introducción: La enfermedad de Ménière se caracteriza por síntomas cocleares y vestibulares. Puede ser unilateral o bilateral. Cuando la pérdida de audición asociada es severa-profunda de forma bilateral o unilateral pero con problemas de audición en el otro oído, dicha audición puede beneficiarse de un implante coclear. Si además, presenta crisis de vértigo y Tumarkin refractarias al tratamiento médico, se puede plantear la realización simultánea de una laberintectomía quirúrgica y colocación de un implante coclear. Descripción: Se describe el caso de un paciente con enfermedad de Ménière bilateral con hipoacusia neurosensorial profunda de oído derecho con fluctuaciones auditivas izquierdas que asocia crisis vertiginosas y de Tumarkin sin respuesta a corticoides orales e intratimpánicos ni a gentamicina intratimpánica. Se le realizó una laberintectomía quirúrgica con implante coclear en el mismo acto quirúrgico anticipándonos al probable deterioro auditivo contralateral. Posteriormente presenta buen rendimiento del implante y desaparición de las crisis del oído intervenido. Discusión: El objetivo del tratamiento es controlar las crisis preservando la función, pero en pacientes en los que las medidas conservadoras fallan, se han de considerar otras más destructivas como es la laberintectomía química, que consigue altas tasas de control de las crisis, y el implante coclear, indicado para restaurar la audición en el oído afectado por enfermedad de Ménière. Si ambas se realizan en un mismo tiempo quirúrgico, se consigue reducir riesgos asociados con otros procedimientos quirúrgicos y anestésicos y evitar las modificaciones histológicas tras una laberintectomía química que dificultarían la posterior colocación del implante colear.

  4. CON EL TRATADO DE LIBRE COMERCIO PERDIMOS TOD@S

    Directory of Open Access Journals (Sweden)

    Mario Rodríguez

    2008-12-01

    Full Text Available Resumen El objetivo principal de este artículo es analizar la inserción de la economía guatemalteca al proceso del desarrollo global del sistema capitalista. El trabajo sustenta la idea de que la estructura productiva se fue configurando a partir de los procesos de ajuste estructural y que la misma tuvo un sesgo marcadamente neoliberal. Esto permitió generar una plataforma política y económica que facilito la imposición de un modelo dependiente con la instauración de un Acuerdo Comercial con Estados Unidos. Este mecanismo es la última fase de la implantación del modelo económico de acumulación, que permite una inserción del capital nacional al gran mercado capitalista mundial y reconfigura la estructura productiva agrícola del país adaptándola a las nuevas necesidades del capital global.   Abstract The Objective of this article is analyzing the insertion of the Guatemalan economy to process of world development of capitalist system. The work support the idea of the productive structure was forming to begin of structures adjustments process and had a slant markedly neoliberal. It allowed produce a politic platform and economic that made easy the imposition of a dependent model with the establishment of one trade agreement with United States. It mechanism is the last stage of the implantation of economic model of accumulation, that allow a insertion of national working capital to big world capitalist market and reforming the farming productive structure of Guatemala; adjustmenting the country to the new necessities of world working capital.

  5. Convivendo com a diversidade sexual: relato de experiência Conviviendo con la diversidad sexual: relato de experiencia Living with sexual diversity: experience report

    Directory of Open Access Journals (Sweden)

    Elma Mathias Dessunti

    2008-06-01

    Full Text Available Este trabalho visa relatar a experiência de alunos e docentes do curso de Graduação em Enfermagem da Universidade Estadual de Londrina junto a uma Organização da Sociedade Civil (OSC, que atua com travestis e garotos de programa. Inicialmente, alunos e docentes permaneciam diariamente na OSC visando o atendimento de necessidades imediatas e semanalmente realizando palestras. Atualmente vêm sendo realizadas oficinas semanais sobre diversidade sexual ministradas pelas travestis aos alunos e docentes. Num segundo momento, as oficinas são ministradas por alunos e docentes abordando temas selecionados previamente pelas travestis. Considera-se esta experiência enriquecedora contribuindo para o crescimento pessoal e profissional de docentes e alunos, assim como para a melhoria da qualidade da assistência e qualidade de vida das travestis.Este trabajo tiene por objetivo relatar la experiência de alumnos y docentes del curso de Graduación de Enfermería de la Universidad Estadual de Londrina junto a una Organización de la Sociedad Civil (OSC, que atua con travestis y " muchachos de programa" . Inicialmente, alumnos y docentes permanecían diariamente en la OSC con la finalidad de ofrecer atención a las necesidades inmediatas y semanalmente para dictar conferencias. Actualmente se están realizando talleres semanales sobre diversidad sexual a cargo de las travestis para los alumnos y docentes. Posteriormente serán alumnos y docentes que abordarán temas seleccionados previamente por las travestis. Esta experiência se há considerado enriquecedora porque há contribuído para el crecimiento personal y profesional de docentes y alumnos, así como para la mejoría de la calidad de la asistencia y calidad de vida de las travestis.This study reports the experience of undergraduate students and faculty from the School of Nursing - Londrina State University, in a Civil Society Organization (CSO that works with transvestites and men who provide

  6. Erbium implantation in Strontium Titanate

    CERN Document Server

    Araújo, J P; Alves, E; Correia, J G; Monteiro, T; Soares, J; Santos, L

    2002-01-01

    We report on the lattice location of Er in SrTiO$_{3}$ single crystals using the emission channeling technique. The angular distribution of conversion electrons emitted from $^{167m}$Er(T$_{1/2}$=2.27 s) was monitored with a position-sensitive detector following the room-temperature 60 keV implantation of the precursor isotope $^{167}$Tm(T$_{1/2}$=9.25 d) to a dose of 2$\\times$ 10$^{12}$ at./cm$^{2}$. The results for the sample annealed in vacuum at 610°C for 15 min provide direct evidence that Er occupies both Sr and Ti substitutional lattice sites. In addition, thermal recovery of lattice damage was also studied with RBS/C for SrTiO$_{3}$ implanted to doses of 5$\\times$ 10$^{14}$ and 5 $\\times$ 10$^{15}$ Er/cm$^{2}$. We further comment on preliminary photoluminescence results from these samples.

  7. Implantable Neural Interfaces for Sharks

    Science.gov (United States)

    2007-05-01

    technology for recording and stimulating from the auditory and olfactory sensory nervous systems of the awake, swimming nurse shark , G. cirratum (Figures...overlay of the central nervous system of the nurse shark on a horizontal MR image. Implantable Neural Interfaces for Sharks ...Neural Interfaces for Characterizing Population Responses to Odorants and Electrical Stimuli in the Nurse Shark , Ginglymostoma cirratum.” AChemS Abs

  8. Tooth Retained Implant: No More an Oxymoron

    Directory of Open Access Journals (Sweden)

    Divya Bhat

    2011-03-01

    Full Text Available Introduction: Periodontally af-fected teeth are treated in one of the two ways. (1 Tooth retention after periodontal surgery, in which the degree of regeneration achieved is unpredictable. (2 Tooth extrac-tion and implant placement. Implants have an osseointegrated surface which does not provide adequate shock absorption. Regeneration can be achieved by resecting the crown of the affected tooth and submerging the root. This technique has not had a clinical application so far as the tooth becomes difficult to restore. Placing an implant within the root can make the retained root restorable. At the same time, as the implant is placed within the root surface it achieves a periodontal integration which dampens occlusal forces better than osseointegration. Therefore, such a “tooth retained implant” may serve as an additional treatment option with significant benefits over tooth retention and implant placement alone. The hypothesis: Implants placed within retained roots have shown cementum deposition and attachment of periodontal ligament fibers over their surface. This periodontal attachment may be able to dam-pen forces better than in an osseointegrated implant. Moreover, since an implant is being placed, the crown of the tooth can be resected and submerged. This prevents epithelial migration, allows for the periodontal ligament cells to populate the wound and favors regeneration.Evaluation of the hypothesis: The technique of placing implants within cavities prepared in the root and then submerging them are simple for any practitioner placing implants routinely.

  9. R&D on dental implants breakage

    Science.gov (United States)

    Croitoru, Sorin Mihai; Popovici, Ion Alexandru

    2017-09-01

    Most used dental implants for human dental prostheses are of two steps type: first step means implantation and, after several months healing and osseointegration, second step is prosthesis fixture. For sure, dental implants and prostheses are meant to last for a lifetime. Still, there are unfortunate cases when dental implants break. This paper studies two steps dental implants breakage and proposes a set of instruments for replacement and restoration of the broken implant. First part of the paper sets the input data of the study: structure of the studied two steps dental implants based on two Romanian patents and values of the loading forces found in practice and specialty papers. In the second part of the paper, using DEFORM 2D™ FEM simulation software, worst case scenarios of loading dental implants are studied in order to determine which zones and components of the dental implant set are affected (broken). Last part of the paper is dedicated to design and presentation of a set for extracting and cutting tools used to restore the broken implant set.

  10. Management of peri-implant infections

    Directory of Open Access Journals (Sweden)

    K L Vandana

    2015-01-01

    Full Text Available The ever-increasing popularity of dental implants in recent years has been associated with the reported incidence of short-term and long-term complications such as peri-implant mucositis and peri-implantitis. Therapies proposed for treating peri-implantitis are based on the evidence available for the treatment of periodontitis, and are aimed at reducing the bacterial load within peri-implant pockets and decontaminating implant surfaces, and, in some cases, attempting afterward to bring about bone regeneration. The treatment of peri-implant infections comprises conservative (nonsurgical and surgical approaches. This paper reviews various treatment strategies used for the treatment of peri-implant diseases. There are many approaches suggested by various authors for the treatment of peri-implant diseases, but there is no “ideal peri-implant therapy” that has been described in the literature. There is no consensus regarding the treatment protocol as the studies conducted so far have had varying study designs, small sample sizes, and short follow-up periods.

  11. Miniscrew implant applications in contemporary orthodontics

    Directory of Open Access Journals (Sweden)

    Hong-Po Chang

    2014-03-01

    Full Text Available The need for orthodontic treatment modalities that provide maximal anchorage control but with minimal patient compliance requirements has led to the development of implant-assisted orthodontics and dentofacial orthopedics. Skeletal anchorage with miniscrew implants has no patient compliance requirements and has been widely incorporated in orthodontic practice. Miniscrew implants are now routinely used as anchorage devices in orthodontic treatment. This review summarizes recent data regarding the interpretation of bone data (i.e., bone quantity and quality obtained by preoperative diagnostic computed tomography (CT or by cone-beam computed tomography (CBCT prior to miniscrew implant placement. Such data are essential when selecting appropriate sites for miniscrew implant placement. Bone characteristics that are indications and contraindications for treatment with miniscrew implants are discussed. Additionally, bicortical orthodontic skeletal anchorage, risks associated with miniscrew implant failure, and miniscrew implants for nonsurgical correction of occlusal cant or vertical excess are reviewed. Finally, implant stability is compared between titanium alloy and stainless steel miniscrew implants.

  12. Customizable cap implants for neurophysiological experimentation.

    Science.gov (United States)

    Blonde, Jackson D; Roussy, Megan; Luna, Rogelio; Mahmoudian, Borna; Gulli, Roberto A; Barker, Kevin C; Lau, Jonathan C; Martinez-Trujillo, Julio C

    2018-04-22

    Several primate neurophysiology laboratories have adopted acrylic-free, custom-fit cranial implants. These implants are often comprised of titanium or plastic polymers, such as polyether ether ketone (PEEK). Titanium is favored for its mechanical strength and osseointegrative properties whereas PEEK is notable for its lightweight, machinability, and MRI compatibility. Recent titanium/PEEK implants have proven to be effective in minimizing infection and implant failure, thereby prolonging experiments and optimizing the scientific contribution of a single primate. We created novel, customizable PEEK 'cap' implants that contour to the primate's skull. The implants were created using MRI and/or CT data, SolidWorks software and CNC-machining. Three rhesus macaques were implanted with a PEEK cap implant. Head fixation and chronic recordings were successfully performed. Improvements in design and surgical technique solved issues of granulation tissue formation and headpost screw breakage. Primate cranial implants have traditionally been fastened to the skull using acrylic and anchor screws. This technique is prone to skin recession, infection, and implant failure. More recent methods have used imaging data to create custom-fit titanium/PEEK implants with radially extending feet or vertical columns. Compared to our design, these implants are more surgically invasive over time, have less force distribution, and/or do not optimize the utilizable surface area of the skull. Our PEEK cap implants served as an effective and affordable means to perform electrophysiological experimentation while reducing surgical invasiveness, providing increased strength, and optimizing useful surface area. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  13. Diferencias psicológicas en pacientes con cáncer de mama según el tipo de cirugía mamaria Psychological differences of breast cancer patients according to the type of breast surgery

    Directory of Open Access Journals (Sweden)

    M.E. Rincón Fernández

    2010-12-01

    Full Text Available Las pacientes con cáncer de mama pueden experimentar importantes secuelas psicológicas producidas por la mastectomía, considerándose la reconstrucción mamaria como un procedimiento reversivo de las mismas. Para conocer si la sintomatología ansiosa y depresiva, las estrategias de afrontamiento empleadas o la calidad de vida manifestada por las pacientes, difiere de unas a otras según el tipo de cirugía realizada (mastectomía unilateral o reconstrucción mamaria se estudiaron 2 grupos. Un primer grupo formado por 36 pacientes sometidas a mastectomía unilateral (simple o radical modificada y un segundo grupo constituido por 36 mujeres con reconstrucción mamaria postmastectomía (inmediata o diferida. Para la evaluación psicológica se empleó una Encuesta Psicosocial, junto a la Escala de Ansiedad y Depresión en Hospital (HAD, la Escala de Afrontamiento del Cáncer (MAC y el Cuestionario de Calidad de Vida para Cáncer de la EORTC (QLQ-C30. En general, las pacientes mastectomizadas presentaron una mayor presencia de sintomatología ansiosa y depresiva que las pacientes con reconstrucción mamaria postmastectomía. Igualmente, las pacientes con reconstrucción mamaria emplearon estrategias de afrontamiento más eficaces y gozaron de una mayor calidad de vida que las mujeres mastectomizadas.Breast cancer patients could experiment an important reduction in psychological adjustment due to mastectomy. So, breast reconstruction is considered a procedure to reverse the sequels of breast mastectomy. Two groups were evaluated in order to determine if anxiety and depression symptoms, coping style and quality of life in breast cancer patients are different for each kind of patient, according to the type of surgery (mastectomy or breast reconstruction. A first group was made up of 36 patients with breast cancer who had undergone unilateral mastectomy (simple or modified radical and the second group was formed by 36 patients with breast

  14. Implantation rate effects on microstructure

    International Nuclear Information System (INIS)

    Choyke, W.J.; Spitznagel, J.A.; Wood, S.; Doyle, N.J.

    1981-01-01

    We report a detailed TEM study of rate effects in a metal (304 SS) where we dope with an insoluble atom (He) and create the displacement damage with high energy Si. The rates of doping and the rates of producing lattice damage are independently varied during dual implantation. In addition to varying the doping rates of the He the magnitude of the displacement damage prior to He implantation is also varied (beam history). We find that the beam history has virtually no effect on maximum bubble size but it has a major effect on the average cavity diameter. A weak dependence of cavity number density on helium implantation rate is found. The total dislocation density is relatively independent of the doping rate and beam history at 550 and 700 0 C, whereas the loop fraction is sensitive to beam history at these temperatures. Acicular precipitate formation is weakly dependent on doping, doping rate and more strongly dependent on doping concentration and temperature. This form of solute segregation is very sensitive to beam history. (orig.)

  15. El maltrato en las personas con discapacidad

    OpenAIRE

    Revuelta, Lucerga

    2014-01-01

    El maltrato no solo se realiza por acción sino también por omisión, la indiferencia hacia la persona con discapacidad es una forma de maltrato muy frecuente. Por ejemplo, ignorar y desatender las necesidades de la persona con discapacidad o, al contrario, la sobreprotección son maneras de maltrato. Cuando a un niño con discapacidad el padre o cuidador le hace todo, el niño se siente agredido pues le están incapacitando más de lo que su enfermedad ya lo hace.

  16. Hiperalgesia asociada al tratamiento con opioides

    OpenAIRE

    A. Gil Martín; M. Moreno García; J. Sánchez-Rubio Ferrández; T. Molina García

    2014-01-01

    La hiperalgesia inducida por opioides es una reacción paradójica caracterizada por una percepción intensificada de dolor relacionada con el uso de estos medicamentos en ausencia de progresión de la enfermedad o de síndrome de retirada. A diferencia de los casos de tolerancia, definida como pérdida de potencia analgésica durante el uso prolongado de opioides, no se produce mejoría con el escalado de dosis. La hiperalgesia inducida por opioides se ha manifestado en pacientes con dosis de manten...

  17. Tratamiento conservador en pacientes con retinoblastoma bilateral

    Directory of Open Access Journals (Sweden)

    Juan C. Suárez

    2008-11-01

    Full Text Available OBJETIVO: comparar el tratamiento convencional del retinoblastoma bilateral, usado hasta hace algunos años, consistente en radioterapia o enucleación bilateral, con el tratamiento conservador actual que incluye termoterapia transpupilar (TTT o TTT/quimioterapia al menos en un ojo, en niños con diagnóstico de retinoblastoma bilateral. DISEÑO: estudio retrospectivo descriptivo. MUESTRA: 20 pacientes con diagnóstico de retinoblastoma bilateral que consultaron al Hospital Universitario San Vicente de Paúl, de Medellín, Colombia, entre 1997 y 2007. MÉTODO: se hizo enucleación del ojo con el tumor de mayor tamaño. En el otro ojo se hizo tratamiento con TTT, con el láser diodo (810 nm, spot amplio, solo o combinado con otras terapias. RESULTADOS: se dividió a los pacientes en dos grupos: 16 pacientes (32 ojos en el grupo 1 tratados conservadoramente y 4 pacientes (8 ojos en el grupo 2 con tratamiento convencional. El rango de edad fue de 1-72 meses en el grupo 1 y de 1-12 meses en el grupo 2. El tiempo de seguimiento fue de 7-67 meses para el grupo 1 y de 13-73 meses para el grupo 2. En el grupo 1 se hizo enucleación de 16 ojos (50%, radioterapia externa de uno (3,1%, quimioterapia más termoterapia de 5 (15,6% y quimioterapia más termoterapia más crioterapia de 10 (31,3%. En todos los pacientes se logró preservar al menos un ojo. En el grupo 2, se enuclearon 7 ojos (87,5% y se hizo radioterapia externa más enucleación en un paciente (12.5%. Además, todos los pacientes recibieron quimioterapia. CONCLUSIÓN: la terapia conservadora actual consistente en tratamiento local (termoterapia, crioterapia o braquiterapia y quimiorreducción permite preservar al menos un ojo y en algunos casos de los dos, muchas veces con buena agudeza visual, en niños con retinoblastoma bilateral; se evitan así la enucleación bilateral y la radioterapia externa usada en el tratamiento convencional con todos sus efectos secundarios. La enucleación contin

  18. Paciente con tumor de cuerpo carotideo

    Directory of Open Access Journals (Sweden)

    Mariuska Forteza Sáez

    Full Text Available Los tumores de cuerpo carotideo (paragangliomas son neoplasias altamente vascularizadas, muy poco frecuentes y generalmente benignas, originadas en los quimiorreceptores del cuerpo carotideo. Se presenta el caso de un paciente de 54 años, con aumento de volumen cervical derecho, asintomático, con estudio preoperatorio y angiografía realizados por tomografía axial computarizada, que resultan compatibles con tumor de cuerpo carotideo. Se realiza disección subadventicial, informando la biopsia paraganglioma. El tumor fue completamente resecado, sin evidencia de recurrencia y sin complicaciones.

  19. Survival of dental implants placed in sites of previously failed implants.

    Science.gov (United States)

    Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-11-01

    To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Influence of different implant materials on the primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Pan, Chin-Yun; Chou, Szu-Ting; Tseng, Yu-Chuan; Yang, Yi-Hsin; Wu, Chao-Yi; Lan, Ting-Hsun; Liu, Pao-Hsin; Chang, Hong-Po

    2012-12-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft(3) trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates(®) device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05). Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success. Copyright © 2012. Published by Elsevier B.V.

  1. Influence of different implant materials on the primary stability of orthodontic mini-implants

    Directory of Open Access Journals (Sweden)

    Chin-Yun Pan

    2012-12-01

    Full Text Available This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm. The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft3 trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates® device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05. Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success.

  2. Pros and cons of vaccination against serogroup B meningococcal disease.

    Science.gov (United States)

    Delgado Rodríguez, Miguel; Domínguez García, Ángela

    2018-02-09

    A vaccine has recently been approved in the EU against meningococcal serogroup B, the main cause of meningococcal disease. There is a fierce debate about the decision regarding a universal vaccination in infants older than 2 months, as recommended by the majority of scientific societies. In western Europe the only country to have included the universal vaccination is the United Kingdom, with a lower incidence of the disease than Ireland. Other countries have also adopted it, such as the Czech Republic, Cuba and certain regions of Italy. Numerous cost-effectiveness studies have been published regarding the vaccination with different assumptions, which have supported the decision not to implant the universal vaccination because it exceeds the will to pay for a health benefit. We discuss the pros and cons of the universal vaccination against meningococcal B, recommended by the Sociedad Española de Pediatría (Spanish Society of Paediatrics), which as yet has not been implemented. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  3. Methods to measure stability of dental implants

    Directory of Open Access Journals (Sweden)

    Shruti Digholkar

    2014-01-01

    Full Text Available Dental implant treatment is an excellent option for prosthetic restoration that is associated with high success rates. Implant stability is essential for a good outcome. The clinical assessment of osseointegration is based on mechanical stability rather than histological criteria, considering primary stability (absence of mobility in bone bed after implant insertion and secondary stability (bone formation and remodeling at implant-bone interface. However, due to the invasive nature of the histological methods various other methods have been proposed: Radiographs, the surgeon′s perception, Insertion torque (cutting torque analysis, seating torque, reverse torque testing, percussion testing, impact hammer method, pulsed oscillation waveform, implant mobility checker, Periotest, resonance frequency analysis. This review focuses on the methods currently available for the evaluation of implant stability.

  4. Electrochemical properties of ion implanted silicon

    International Nuclear Information System (INIS)

    Pham minh Tan.

    1979-11-01

    The electrochemical behaviour of ion implanted silicon in contact with hydrofluoric acid solution was investigated. It was shown that the implanted layer on silicon changes profoundly its electrochemical properties (photopotential, interface impedance, rest potential, corrosion, current-potential behaviour, anodic dissolution of silicon, redox reaction). These changes depend strongly on the implantation parameters such as ion dose, ion energy, thermal treatment and ion mass and are weakly dependent on the chemical nature of the implantation ion. The experimental results were evaluated and interpreted in terms of the semiconductor electrochemical concepts taking into account the interaction of energetic ions with the solid surface. The observed effects are thus attributed to the implantation induced damage of silicon lattice and can be used for profiling of the implanted layer and the electrochemical treatment of the silicon surface. (author)

  5. Early Loaded Single Implant Reinforced Mandibular Overdenture

    Directory of Open Access Journals (Sweden)

    K. Nischal

    2016-01-01

    Full Text Available Rehabilitating atrophied mandible with two-implant supported denture is a common treatment modality for implant retained removable overdenture in mandible. This paper aims to design a treatment modality where single implant reinforced overdenture is fabricated for a severely atrophied mandibular ridge with early loading protocol. Results of studies have shown that a single implant mandibular overdenture significantly increases the satisfaction and quality of life of patients with edentulism. Midline fracture of the prosthesis is the most common complication related to single implant and two-implant retained mandibular overdentures. To manage such complication, a thin metal mesh is used to reinforce the overdenture and also to make the prostheses lighter and cost effective as compared to conventional cast metal framework.

  6. Implant supported overdentures--the Copenhagen experience

    DEFF Research Database (Denmark)

    Gotfredsen, K

    1997-01-01

    OBJECTIVES: To evaluate the functional and biological effect of implant-supported overdenture treatment in the lower jaw. METHODS AND MATERIALS: Thirty-two patients were consecutively treated with Astra Tech implants in the lower jaw for retaining overdentures. All implants had a diameter of 3.5 mm...... and all but two of the implants were longer than 10 mm. For the implant supported overdentures two methods of attachment were used, a bar or a ball. RESULTS: One of 69 fixtures was lost during the 4-5 year observation period. The mean bone loss for all fixtures was less than 0.2 mm per year. Complications...... quality and quantity is sufficient, two implants can support an overdenture in the lower jaw, providing prosthesis which functions well....

  7. [Fusion implants of carbon fiber reinforced plastic].

    Science.gov (United States)

    Früh, H J; Liebetrau, A; Bertagnoli, R

    2002-05-01

    Carbon fiber reinforced plastics (CFRP) are used in the medical field when high mechanical strength, innovative design, and radiolucency (see spinal fusion implants) are needed. During the manufacturing process of the material CFRP carbon fibers are embedded into a resin matrix. This resin material could be thermoset (e.g., epoxy resin EPN/DDS) or thermoplastic (e.g., PEAK). CFRP is biocompatible, radiolucent, and has higher mechanical capabilities compared to other implant materials. This publication demonstrates the manufacturing process of fusion implants made of a thermoset matrix system using a fiber winding process. The material has been used clinically since 1994 for fusion implants of the cervical and lumbar spine. The results of the fusion systems CORNERSTONE-SR C (cervical) and UNION (lumbar) showed no implant-related complications. New implant systems made of this CFRP material are under investigation and are presented.

  8. A case of peri-implantitis and osteoradionecrosis arising around dental implants placed before radiation therapy

    OpenAIRE

    Teramoto, Yuji; Kurita, Hiroshi; Kamata, Takahiro; Aizawa, Hitoshi; Yoshimura, Nobuhiko; Nishimaki, Humihiro; Takamizawa, Kazunobu

    2016-01-01

    A little is known about the effect of radiotherapy on the dental implants that have previously been osseointegrated and charged. Here, we reported a case of osteoradionecrosis which arose around dental implants placed before radiation therapy.

  9. Long time follow up of implant therapy and treatment of peri-implantitis.

    Science.gov (United States)

    Roos-Jansåker, Ann-Marie

    2007-01-01

    Dental implants have become an often used alternative to replace missing teeth, resulting in an increasing percentage of the adult population with implant supported prosthesis. Although favourable long-term results of implant therapy have been reported, infections occur. Until recently few reports included data on peri-implant infections, possibly underestimating this complication of implant treatment. It is possible that some infections around implants develop slowly and that with time peri-implantitis will be a common complication to implant therapy as an increasing number of patients have had their implants for a long time (>10 years). Data on treatment of peri-implant lesions are scarce leaving the clinician with limited guidance regarding choice of treatment. The aim of this thesis was to study the frequency of implant loss and presence of peri-implant lesions in a group of patients supplied with Brånemark implants 9-14 years ago, and to relate these events to patient and site specific characteristics. Moreover three surgical treatment modalities for peri-implantitis were evaluated. The thesis is based on six studies; Studies I-III included 218 patients and 1057 implants followed for 9-14 years evaluating prevalence of, and factors related to implant loss (Paper I) and prevalence of peri-implant infections and related factors (Paper I-III). Study IV is a review describing different treatment modalities of peri-implant infections. Study V is a prospective cohort study involving 36 patients and 65 implants, evaluating the use of a bone substitute with or without the use of a resorbable membrane. Study VI is a case series with 12 patients and 16 implants, evaluating a bone substitute in combination with a resorbable membrane and submerged healing. This thesis demonstrated that: After 9-14 years the survival rates of dental implants are high (95.7%). Implant loss seems to cluster within patients and are related to periodontitis evidenced as bone loss on

  10. Infective endocarditis and risk of death after cardiac implantable electronic device implantation

    DEFF Research Database (Denmark)

    Özcan, Cengiz; Raunsø, Jakob; Lamberts, Morten

    2017-01-01

    AIMS: To determine the incidence, risk factors, and mortality of infective endocarditis (IE) following implantation of a first-time, permanent, cardiac implantable electronic device (CIED). METHODS AND RESULTS: From Danish nationwide administrative registers (beginning in 1996), we identified all...

  11. Presa con revestimiento asfáltico

    Directory of Open Access Journals (Sweden)

    Proudfit, D. P.

    1960-07-01

    Full Text Available La presa denominada Montgomery se halla situada sobre el río South Platte River, a unos 8 km aguas arriba de la ciudad de Alma, del Estado de Colorado (EE. UU., y en la ladera oriental de la cordillera Continental Divide. El cuerpo o dique de esta presa está constituido por piedra, revestida con una capa de hormigón asfáltico en el paramento de contacto con el agua.

  12. Trastornos temporomandibulares en pacientes con maloclusiones

    Directory of Open Access Journals (Sweden)

    Luis Soto Cantero

    Full Text Available Introducción: existe una prevalencia de trastornos oclusales en gran medida relacionados con la presencia de disfunción temporomandibular. Objetivo: determinar el grado de disfunción temporomandibular según el Índice de Maglione en correspondencia con la prevalencia de maloclusiones en el área de salud del policlínico "Turcios Lima". Métodos: se realizó un estudio observacional descriptivo, de corte transversal, en la consulta de ortodoncia, de junio del 2008 a junio del 2009. De un universo constituido por los 280 pacientes que acudieron al servicio de ortodoncia en el período señalado con presencia de maloclusiones, se seleccionó una muestra de 84 pacientes por muestreo aleatorio simple, teniendo en cuenta los criterios de inclusión y exclusión realizados por criterios de expertos. Resultados: presentaban disfunción temporomandibular 74 pacientes y dentro de ellos 44 (52,4 % tenían disfunción grado II (Moderada. El 97 % de los pacientes con relación molar de clase II, presentaban disfunción temporomandibular. El 42,9 % de los pacientes con una maloclusión, presentaban disfunción grado I. El 60 % de los pacientes con dos maloclusiones presentaban disfunción grado II y el 66,7 % de los pacientes con tres maloclusiones, presentaban disfunción grado III. La mayor cantidad de pacientes tuvieron disfunción grado II (Moderada. Conclusiones: el mayor por ciento de los pacientes con disfunciones presentó una clase II molar y a medida que aumentó el número de maloclusiones aumentó también la severidad de la disfunción.

  13. Strain driven fast osseointegration of implants

    Directory of Open Access Journals (Sweden)

    Wiesmann Hans-Peter

    2005-09-01

    Full Text Available Abstract Background Although the bone's capability of dental implant osseointegration has clinically been utilised as early as in the Gallo-Roman population, the specific mechanisms for the emergence and maintenance of peri-implant bone under functional load have not been identified. Here we show that under immediate loading of specially designed dental implants with masticatory loads, osseointegration is rapidly achieved. Methods We examined the bone reaction around non- and immediately loaded dental implants inserted in the mandible of mature minipigs during the presently assumed time for osseointegration. We used threaded conical titanium implants containing a titanium2+ oxide surface, allowing direct bone contact after insertion. The external geometry was designed according to finite element analysis: the calculation showed that physiological amplitudes of strain (500–3,000 ustrain generated through mastication were homogenously distributed in peri-implant bone. The strain-energy density (SED rate under assessment of a 1 Hz loading cycle was 150 Jm-3 s-1, peak dislocations were lower then nm. Results Bone was in direct contact to the implant surface (bone/implant contact rate 90% from day one of implant insertion, as quantified by undecalcified histological sections. This effect was substantiated by ultrastructural analysis of intimate osteoblast attachment and mature collagen mineralisation at the titanium surface. We detected no loss in the intimate bone/implant bond during the experimental period of either control or experimental animals, indicating that immediate load had no adverse effect on bone structure in peri-implant bone. Conclusion In terms of clinical relevance, the load related bone reaction at the implant interface may in combination with substrate effects be responsible for an immediate osseointegration state.

  14. Characterization of diamond amorphized by ion implantation

    International Nuclear Information System (INIS)

    Allen, W.R.; Lee, E.H.

    1992-01-01

    Single crystal diamond has been implanted at 1 MeV with 2 x 10 20 Ar/m 2 . Rutherford backscattering spectrometry in a channeled geometry revealed a broad amorphized region underlying a thin, partially crystalline layer. Raman spectroscopy disclosed modifications in the bonding characteristic of the appearance of non-diamond carbon. The complementary nature of the two analysis techniques is demonstrated. The Knoop hardness of the implanted diamond was reduced by implantation

  15. Modification of metallic corrosion by ion implantation

    International Nuclear Information System (INIS)

    Clayton, C.R.

    1981-01-01

    This review will consider some of the properties of surface alloys, formed by ion implantation, which are effective in modifying corrosion behaviour. Examples will be given of the modification of the corrosion behaviour of pure metals, steels and other engineering alloys, resulting from implantation with metals and metalloids. Emphasis will be given to the modification of anodic processes produced by ion implantation since a review will be given elsewhere in the proceedings concerning the modification of cathodic processes. (orig.)

  16. Relation between bruxism and dental implants

    OpenAIRE

    TORCATO,Leonardo Bueno; ZUIM,Paulo Renato Junqueira; BRANDINI,Daniela Atili; FALCÓN-ANTENUCCI,Rosse Mary

    2014-01-01

    OBJECTIVE: The aim of this study was to gather information and discuss the predictability of implant-supported prostheses in patients with bruxism by performing a literature review.METHODS: In order to select the studies included in this review, a detailed search was performed in PubMed and Medlinedatabases, using the following key words: bruxism, dental implants, implant supported prosthesis, and dental restoration failure. Items that were included are: case reports, randomized controlled tr...

  17. CEMS of Sb+ implanted stainless steels

    International Nuclear Information System (INIS)

    Roy-Poulsen, H.; Johnson, E.; Johansen, A.; Sarholt-Kristensen, L.; Hayashi, H.

    1986-01-01

    Martensitic transformations have been analyzed in a series of antimony implanted austenitic stainless steels using CEMS. The implanted samples contain about 70 vol% martensite, which is considerably more than can be formed conventionally by plastic deformation of cooling below the martensite start temperature. CEM spectra from implantation induced martensite and from martensite formed in conventional processes are virtually identical. In both cases the hyperfine field is ∼ 25T. (Auth.)

  18. CEMS of Sb+ implanted stainless steels

    International Nuclear Information System (INIS)

    Roy-Poulsen, H.; Copenhagen Univ.; Johnson, E.; Johansen, A.; Sarholt-Kristensen, L.; Hayashi, H.

    1985-01-01

    Martensitic transformations have been analyzed in a series of antimony implanted austenitic stainless steels using CEMS. The implanted samples contain about 70 vol% martensite, which is considerably more than can be formed conventionally by plastic deformation or cooling below the martensite start temperature. CEM spectra from implantation induced martensite and from martensite formed in conventional processes are virtually identical. In both cases the hyperfine field is ∝25 T. (orig.)

  19. Cochlear implant revision surgeries in children.

    Science.gov (United States)

    Amaral, Maria Stella Arantes do; Reis, Ana Cláudia Mirândola B; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2018-02-16

    The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant Surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after Cochlear Implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  20. Angioplastia del seno coronario en el implante de electrodo del ventrículo izquierdo Angioplasty of coronary sinus in left ventricle electrode implant

    Directory of Open Access Journals (Sweden)

    Alejandro Orjuela

    2011-07-01

    Full Text Available Con el incremento de implantes de dispositivos de estimulación cardíaca en pacientes con miocardiopatía dilatada, el diseno día a día más sofisticado de los mismos para satisfacer los requerimientos de los pacientes con cambios anatómicos que surgen como consecuencia de la misma dilatación cardíaca, tales como modificaciones en el calibre, curso, longitud y número de venas coronarias, cada vez se encuentran mayores dificultades para lograr los objetivos anatómicos, en particular el sitio ideal de posicionamiento del electrodo de estimulación ventricular izquierda en el seno coronario. Esta situación limita, en algunos casos, el beneficio terapéutico de esta técnica, viéndose, en ocasiones, en la necesidad de someter al paciente a toracotomía para posicionar el electrodo en el epicardio posterolateral del ventrículo izquierdo. Es así como, con el objetivo de abreviar los tiempos y la morbimortalidad e incrementar el éxito del implante, se disenó una estrategia basada en la técnica de hemodinámica para vencer las obstrucciones de las arterias coronarias y lograr, mediante angioplastia de las estrecheces del seno coronario, un abordaje más preciso a un determinado vaso epicárdico preseleccionado. Se describe la técnica usada en la angioplastia del seno coronario para este propósito.The design of devices of cardiac stimulation in patients with dilated cardiomyopathy has become more sophisticated due to the increment of its implantation, devices that must satisfy the requirements for patients with anatomical changes that appear as a consequence of the cardiac dilation such as caliber modifications, course, length and number of coronary veins. Every time is more difficult to achieve the anatomical objectives, particularly the ideal place for the left ventricular stimulation electrode position in the coronary sinus. This situation limits in some cases the therapeutical benefit of this technique, occasionally facing to the

  1. RadCon: A Radiological Consequences Model

    International Nuclear Information System (INIS)

    Crawford, J.; Domel, R.U.

    2000-05-01

    RadCon estimates the dose received by user selected groups in the population from an accidental release of radionuclides to the environment. The exposure pathways considered are external exposure from the cloud and ground and internal exposure from inhalation and ingestion of contaminated food. Atmospheric dispersion modelling is carried out externally to RadCon.Given a two dimensional time varying air and ground concentration of radioactive elements, RadCon allows the user to: view the air and ground concentration over the affected area, select optional parameters and calculate the dose to people,display the results to the user, and change the parameter values. RadCon offers two user interfaces: 1) the standard graphical user interface which is started using Java DoseApp at the command line, or by setting up a shortcut to this command (particularly when RadCon is installed on a PC) and 2) the text based interface used to generate information for the model inter-comparison exercise . This is initiated using Java BIOMASS at the command line, or an equivalent shortcut. The text based interface was developed for research purposes and is not generally available. Appendices A, B and C provide a summary of instructions on setting up RadCon. This will generally be carried out by the computer support personnel

  2. Adolescente femenino con granulomatosis de Wegener fulminante

    Directory of Open Access Journals (Sweden)

    S C Scheffler-Mendoza

    2017-01-01

    Full Text Available Adolescente femenino de 13 años de edad, originaria de Guerrero, grupo étnico mixteco, padres analfabetos y con poco entendimiento del español. Sin otros antecedentes de importancia para el padecimiento. Inició un mes previo con la aparición de una pápula hipercrómica en párpado superior derecho que en los 10 días previos al ingreso aumentó de volumen generando proptosis. Al interrogatorio se negó dolor, lagrimeo, fiebre, o pérdida de peso. Ingresó con fiebre (39.0°C, palidez generalizada, proptosis derecha con exposición de córnea y conjuntiva, eritema periorbitario, movimientos oculares y agudeza visual disminuidos (i.e. contaba dedos a 1 m, pupila con tendencia a midriasis, hiperreactividad a la luz, y fondo de ojo con papila hiperémica edematosa y tortuosidad peripapilar. El resto de exploración no mostró datos relevantes. Se hospitalizó para iniciar tratamiento antimicrobiano parenteral de amplio espectro (i.e. ceftriaxona y vancomicina y abordar proptosis unilateral.

  3. One-stage explant-implant procedure of exposed porous orbital implants

    DEFF Research Database (Denmark)

    Toft, Peter B; Rasmussen, Marie L Roed; Prause, Jan Ulrik

    2011-01-01

    Purpose:  To investigate the risks of implant exposure after a combined explant-implant procedure in patients with an exposed porous orbital implant. Methods:  Twenty-four consecutive patients who had a combined explant-implant procedure of an exposed hydroxyapatite (21) or porous polyethylene (3...... at the same procedure in sockets without profound signs of infection. The procedure carries a possible risk of poor motility....

  4. Systemic alendronate treatment improves fixation of press-fit implants: a canine study using nonloaded implants

    DEFF Research Database (Denmark)

    Jensen, Thomas B; Bechtold, Joan E; Chen, Xinqian

    2007-01-01

    of alendronate treatment. Bone ongrowth (bone in contact with implant surface) was estimated using the linear intercept technique and shear strength was calculated as the slope on a load-displacement curve. For the press fit implants, alendronate treatment significantly increased bone ongrowth from 24% to 29...... early implant stability is an important predictor of longevity, systemic alendronate treatment could be an important clinical tool to positively influence the early stages of implant incorporation. Udgivelsesdato: 2007-Jun...

  5. El Implante discal cervical como alternativa a la artrodesis en el tratamiento quirúrgico de la cervicoartrosis

    OpenAIRE

    Lafuente Baraza, Jesús

    2004-01-01

    Consultable des del TDX Títol obtingut de la portada digitalitzada Objetivo: Evaluación de la prótesis de Bryan como alternativa a la artrodesis en el tratamiento de la espondilosis cervical. Materiales y métodos: 54 pacientes consecutivos con radiculopatía o mielopatía fueron intervenidos quirúrgicamente de discectomía cervical con implantación de la prótesis discal cervical. Dichos implantes presentan medidas variables que van de 14 a 18 mm. El seguimiento se realizo a las seis semana...

  6. Neural Implants, Packaging for Biocompatible Implants, and Improving Fabricated Capacitors

    Science.gov (United States)

    Agger, Elizabeth Rose

    We have completed the circuit design and packaging procedure for an NIH-funded neural implant, called a MOTE (Microscale Optoelectronically Transduced Electrode). Neural recording implants for mice have greatly advanced neuroscience, but they are often damaging and limited in their recording location. This project will result in free-floating implants that cause less damage, provide rapid electronic recording, and increase range of recording across the cortex. A low-power silicon IC containing amplification and digitization sub-circuits is powered by a dual-function gallium arsenide photovoltaic and LED. Through thin film deposition, photolithography, and chemical and physical etching, the Molnar Group and the McEuen Group (Applied and Engineering Physics department) will package the IC and LED into a biocompatible implant approximately 100microm3. The IC and LED are complete and we have begun refining this packaging procedure in the Cornell NanoScale Science & Technology Facility. ICs with 3D time-resolved imaging capabilities can image microorganisms and other biological samples given proper packaging. A portable, flat, easily manufactured package would enable scientists to place biological samples on slides directly above the Molnar group's imaging chip. We have developed a packaging procedure using laser cutting, photolithography, epoxies, and metal deposition. Using a flip-chip method, we verified the process by aligning and adhering a sample chip to a holder wafer. In the CNF, we have worked on a long-term metal-insulator-metal (MIM) capacitor characterization project. Former Fellow and continuing CNF user Kwame Amponsah developed the original procedure for the capacitor fabrication, and another former fellow, Jonilyn Longenecker, revised the procedure and began the arduous process of characterization. MIM caps are useful to clean room users as testing devices to verify electronic characteristics of their active circuitry. This project's objective is to

  7. Uso de osteocoral como material de implante en bolsas infraóseas de dientes Monorradiculares

    Directory of Open Access Journals (Sweden)

    . Yamilé Hernández Alemán,

    1999-12-01

    Full Text Available Se evaluó la eficacia del osteocoral como material de implante en el tratamiento de bolsas infraóseas de dientes monorradiculares. Se realizaron 18 injertos en 17 dientes con defectos angulares, en 6 pacientes de ambos sexos; 9 implantes correspondieron al grupo control con hidroxiapatita y 9 al grupo de estudio que fue implantado con osteocoral. Se realizó preparación inicial que incluyó: remoción de cálculos y pulido de las superficies dentarias, educación y motivación sobre el tratamiento recibido, corrección del cepillado igual o mayor al 80 % en la remoción de placa dentobacteriana. Se realizó el implante mediante operación a colgajo, con sutura y colocación de apósito periodontal. Se realizaron radiografías de control a los 14 días, a los 3 y 6 meses. Se controló sistemáticamente la higiene bucal. A los 6 meses se registraron nuevamente los indicadores clínicos. El análisis final de los resultados mostró una disminución estadísticamente significativa en el índice gingival, profundidad de la bolsa al sondeo y movilidad dentaria para ambos materiales implantológicos. No se reportaron grandes diferencias entre éstos para este tamaño de muestra, no hubo reacciones adversas y se logró la permanencia del implante de osteocoral, por lo que se consideró efectivo el tratamiento.Effectivenes of osteocoral as implant material was assessed to treat infraosseous pockets of multirooted teeth. 18 grafts were inserted in 17 teeth with angular defects in 6 patients of both sexes; 9 implants corresponded to control group (hydroxiapatite and 9 corresponded to study group (osteocoral. Initial preparation included: removal of calculus and polishing of dental surface, education and motivation about treatment applied, correction of tooth-brushing equal or greater 80 % in removal of dentobacterial plaque. Implant was inserted by flap surgery using suture and placement of periodontal dresssing. Control X-rays were made within 14 days

  8. Trends in prosthetic biomaterials in implant dentistry

    Directory of Open Access Journals (Sweden)

    Saranjit Singh Bhasin

    2015-01-01

    Full Text Available The most important criterion for the success of dental implants is the selection of a suitable implant biomaterial. To improve the biologic performance of an implant, it is necessary to select a material that does not elicit any negative biological response and at the same time maintains adequate function. It is mandatory for a dentist to have a comprehensive knowledge of various biomaterials used for dental implants. The material of choice for fabrication of the dental implant till date is titanium. With the advancements in the field of implants, zirconia seems to be propitious in the future. However, more advanced in vitro and in vivo studies are required before reaching any such conclusion. To increase the success of zirconia implants, care should be taken to reduce the incidence of mechanical failures. Such failures can be taken care of by having a thorough technical knowledge of implant designing and manufacturing defects. This article attempts to compare the advantages and disadvantages of various dental implant biomaterials. Focus is placed on the recent advances in this field with the recently introduced zirconia and its comparison to conventional titanium.

  9. He implantation induced nanovoids in crystalline Si

    International Nuclear Information System (INIS)

    Kilpelaeinen, S.; Kuitunen, K.; Slotte, J.; Tuomisto, F.; Bruno, E.; Mirabella, S.; Priolo, F.

    2009-01-01

    Positron annihilation spectroscopy (PAS) in Doppler broadening mode was used to study the vacancy profile of crystalline Si after He and B implantation and subsequent annealing. In the He-implanted samples two different void layers were observed, one consisting of large voids at the projected range of He and another containing 'nanovoids' slightly larger than divacancies at roughly halfway between R p of He and the surface. The nanovoid layer was shown to be absent from samples co-implanted with B, implying that interstitials created during B implantation get trapped in the nanovoids and fill them, thus hindering interstitial-mediated B diffusion.

  10. Ion implantation of boron in germanium

    International Nuclear Information System (INIS)

    Jones, K.S.

    1985-05-01

    Ion implantation of 11 B + into room temperature Ge samples leads to a p-type layer prior to any post implant annealing steps. Variable temperature Hall measurements and deep level transient spectroscopy experiments indicate that room temperature implantation of 11 B + into Ge results in 100% of the boron ions being electrically active as shallow acceptor, over the entire dose range (5 x 10 11 /cm 2 to 1 x 10 14 /cm 2 ) and energy range (25 keV to 100 keV) investigated, without any post implant annealing. The concentration of damage related acceptor centers is only 10% of the boron related, shallow acceptor center concentration for low energy implants (25 keV), but becomes dominant at high energies (100 keV) and low doses ( 12 /cm 2 ). Three damage related hole traps are produced by ion implantation of 11 B + . Two of these hole traps have also been observed in γ-irradiated Ge and may be oxygen-vacancy related defects, while the third trap may be divacancy related. All three traps anneal out at low temperatures ( 0 C). Boron, from room temperature implantation of BF 2 + into Ge, is not substitutionally active prior to a post implant annealing step of 250 0 C for 30 minutes. After annealing additional shallow acceptors are observed in BF 2 + implanted samples which may be due to fluorine or flourine related complexes which are electrically active

  11. Endothelial cell adhesion to ion implanted polymers

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Y; Kusakabe, M [SONY Corp., Tokyo (Japan); Lee, J S; Kaibara, M; Iwaki, M; Sasabe, H [RIKEN (Inst. of Physical and Chemical Research), Saitama (Japan)

    1992-03-01

    The biocompatibility of ion implanted polymers has been studied by means of adhesion measurements of bovine aorta endothelial cells in vitro. The specimens used were polystyrene (PS) and segmented polyurethane (SPU). Na{sup +}, N{sub 2}{sup +}, O{sub 2}{sup +} and Kr{sup +} ion implantations were performed at an energy of 150 keV with fluences ranging from 1x10{sup 15} to 3x10{sup 17} ions/cm{sup 2} at room temperature. The chemical and physical structures of ion-implanted polymers have been investigated in order to analyze their tissue compatibility such as improvement of endothelial cell adhesion. The ion implanted SPU have been found to exhibit remarkably higher adhesion and spreading of endothelial cells than unimplanted specimens. By contrast, ion implanted PS demonstrated a little improvement of adhesion of cells in this assay. Results of FT-IR-ATR showed that ion implantation broke the original chemical bond to form new radicals such as OH, ....C=O, SiH and condensed rings. The results of Raman spectroscopy showed that ion implantation always produced a peak near 1500 cm{sup -1}, which indicated that these ion implanted PS and SPU had the same carbon structure. This structure is considered to bring the dramatic increase in the extent of cell adhesion and spreading to these ion implanted PS and SPU. (orig.).

  12. Prevention and management of cochlear implant infections.

    Science.gov (United States)

    Gluth, Michael B; Singh, Rajesh; Atlas, Marcus D

    2011-11-01

    Understanding the issues of infection related to an implantable medical device is crucial to all cochlear implant teams. Furthermore, given the risk of central nervous system complications and the relatively high quantity of underlying resource investment associated with cochlear implantation, the stakes of infection are high. The optimal strategies to prevent and manage such infections are still evolving as good-quality prospective data to guide such management decisions are not yet abundant within the medical literature and many recommendations are based on retrospective reviews or anecdotal evidence. We will outline a general strategy to deal with cochlear implant-related infection based on both the authors' experience and the published literature.

  13. Digital photoelastic analysis applied to implant dentistry

    Science.gov (United States)

    Ramesh, K.; Hariprasad, M. P.; Bhuvanewari, S.

    2016-12-01

    Development of improved designs of implant systems in dentistry have necessitated the study of stress fields in the implant regions of the mandible/maxilla for better understanding of the biomechanics involved. Photoelasticity has been used for various studies related to dental implants in view of whole field visualization of maximum shear stress in the form of isochromatic contours. The potential of digital photoelasticity has not been fully exploited in the field of implant dentistry. In this paper, the fringe field in the vicinity of the connected implants (All-On-Four® concept) is analyzed using recent advances in digital photoelasticity. Initially, a novel 3-D photoelastic model making procedure, to closely mimic all the anatomical features of the human mandible is proposed. By choosing appropriate orientation of the model with respect to the light path, the essential region of interest were sought to be analysed while keeping the model under live loading conditions. Need for a sophisticated software module to carefully identify the model domain has been brought out. For data extraction, five-step method is used and isochromatics are evaluated by twelve fringe photoelasticity. In addition to the isochromatic fringe field, whole field isoclinic data is also obtained for the first time in implant dentistry, which could throw important information in improving the structural stability of the implant systems. Analysis is carried out for the implant in the molar as well as the incisor region. In addition, the interaction effects of loaded molar implant on the incisor area are also studied.

  14. High energy ion implantation for IC processing

    International Nuclear Information System (INIS)

    Oosterhoff, S.

    1986-01-01

    In this thesis the results of fundamental research on high energy ion implantation in silicon are presented and discussed. The implantations have been carried out with the 500 kV HVEE ion implantation machine, that was acquired in 1981 by the IC technology and Electronics group at Twente University of Technology. The damage and anneal behaviour of 1 MeV boron implantations to a dose of 10 13 /cm 2 have been investigated as a function of anneal temperature by sheet resistance, Hall and noise measurements. (Auth.)

  15. High energy P implants in silicon

    International Nuclear Information System (INIS)

    Raineri, V.; Cacciato, A.; Benyaich, F.; Priolo, F.; Rimini, E.; Galvagno, G.; Capizzi, S.

    1992-01-01

    Phosphorus ions in the energy range 0.25-1 MeV and in the dose range 2x10 13 -1x10 15 P/cm 2 were implanted into (100) Si single crystal at different tilt angles. In particular channeling and random conditions were investigated. For comparison some implants were performed on samples with a 2 μm thick surface amorphous layer. Chemical concentration P profiles were obtained by secondary ion mass spectrometry. Carrier concentration and mobility profile measurements were carried out by sheet resistance and Hall measurements on implanted van der Pauw patterns. Carrier concentration profiles were also obtained by spreading resistance (SR) measurements. The damage in the as-implanted samples was determined by backscattering and channeling spectrometry (RBS) as a function of the dose and implantation energy. Comparison of random implants in crystal with implants in amorphous layers shows that in the first case it is impossible to completely avoid the channeling tail. In the implants performed under channeling conditions at low doses the P profiles are flat over more than 2 μm thick layers. Furthermore, by increasing the implanted dose, the shape of the profiles dramatically changes due to the dechanneling caused by the crystal disorder. The data are discussed and compared with Monte Carlo simulations using the MARLOWE code. A simple description of the electronic energy loss provides an excellent agreement between the calculated and experimental profiles. (orig.)

  16. Helium implantation effects in SAP and aluminum

    International Nuclear Information System (INIS)

    Bauer, W.; Thomas, G.J.

    1976-02-01

    A series of 300 keV He implantations of Al and SAP 930 have been conducted at temperatures between 150 and 773K. The He re-emission was monitored during implantation and the samples were examined with a scanning electron microscope after implantation. Both Al and SAP 930 were found to blister after a critical He dose was reached at temperatures above 473K, both underwent flaking below that temperature, with blistering re-appearing in SAP 930 at an implantation temperature of 150K. The surface deformation and He re-emission are strongly dependent on microstructural effects in the intermediate temperature regime

  17. Determining factors for implant referral rates.

    Science.gov (United States)

    Levin, Roger P

    2002-01-01

    The research findings indicate that the field of implant dentistry will only grow at a moderately low level unless certain changes are made. Findings indicated that the effort by the implant companies has been nothing short of dramatic, and yet almost 60% of restorative doctors do not participate annually in any implant case. There was no clear indication that younger restorative doctors will significantly increase the number of implant referrals, as their overall implant education has not dramatically differed from those dentists who graduated in earlier years. Once the research was completed, it became obvious to Levin Group that the driving force behind implant referral growth will be implant surgeons, because of their one-to-one relationship with restorative doctors. The Levin Group Implant Management and Marketing Consulting Program is based on approaching restorative doctors in several different levels, starting with awareness all the way through to case facilitation and long-term tracking and communication. Finally, a continuing marketing/education effort needs to be consistently in place with effective materials, not only to create a high level of awareness, but also to motivate restorative doctors to refer cases and then work through the case with the implant surgeon to a satisfactory completion for the restorative doctor, implant surgeon, and patient. While the surgical insertion of implants may seem to carry a high-profit margin relative to the restoration of implants, the truth is that the restoration of implants usually provides a 40% higher profit margin for the restorative doctor than traditional dental services. One of the key issues is that referring doctors have not necessarily learned how to set fees and present cases with regard to implant dentistry. The key factor here is to ensure that the patient understands that implant services involve higher fees than traditional services, because of the necessarily higher levels of experience, education

  18. Treatment planning of implants in posterior quadrants.

    Science.gov (United States)

    Jivraj, S; Chee, W

    2006-07-08

    Differences in anatomy and biomechanics make treatment of posterior quadrants with dental implants substantially different to that of anterior areas. Without implants, when posterior teeth were lost, treatment options included a long span fixed partial denture or a removable prosthesis, especially when no terminal abutment was available. Today, with the use of implants, options are available that allow preservation of unrestored teeth.(1) When teeth are missing, implant supported restorations can be considered the treatment of choice from the perspective of occlusal support, preservation of adjacent teeth and avoidance of a removable partial denture.

  19. Mandibular implant-supported overdentures: Prosthetic overview

    Directory of Open Access Journals (Sweden)

    Fahad A Al-Harbi

    2018-01-01

    Full Text Available Implant-supported overdentures are becoming the treatment of choice for the completely edentulous mandible. They significantly improve the quality of life in edentulous patients. For this review article, the literature was searched to identify pertinent studies. No meta-analysis was conducted because of high heterogeneity within the literature. Accordingly, in this review article, the author provides an update on implant-supported mandible overdentures with regard to the number of implants, type of loading, stress–strain distribution, mode of implant-to-denture attachment, occlusal considerations and complications.

  20. Repercusión del implante coclear en el aprendizaje de la lectura de los alumnos sordos: resultados preliminares

    Directory of Open Access Journals (Sweden)

    Ana Belén DOMÍNGUEZ GUTIÉRREZ

    2009-05-01

    Full Text Available RESUMEN: El propósito de este trabajo es mostrar unos primeros resultados que permitan comprobar la repercusión que están teniendo los implantes cocleares (ayudas técnicas que transforman las señales acústicas en señales eléctricas que estimulan el nervio auditivo en el aprendizaje de la lectura de los alumnos sordos. Para ello, se analizan los mecanismos de lectura desarrollados por dos grupos de alumnos sordos, con y sin implante coclear, a lo largo de la escolaridad obligatoria; tomando como referencia un grupo de alumnos oyentes de la misma edad. Los resultados muestran que existen diferencias en los mecanismos de lectura en función del uso de los implantes cocleares. Los alumnos sordos con implante coclear usan mecanismos semánticos y sintácticos en la lectura de oraciones y emplean códigos ortográficos y fonológicos; mientras que los alumnos sordos sin implante coclear usan preferentemente mecanismos semánticos y códigos ortográficos en lectura. En consecuencia, se analizan las implicaciones de estos resultados para la práctica educativa.ABSTRACT: The first aim of the present paper is to show a preliminary findings about the repercussion of cochlear implant in reading acquisition in deaf children. For this, reading strategies were analyzed in two groups of deaf children, with and without cochlear implants, during compulsory schooling. Their performance was compared with that hearing children of the same chronological age. The findings suggest that there are differences in reading strategies in funtion of the use of cochlear implants. The children who had received a cochlear implantation can use semantic and sintactic strategies in reading sentences, and they can use orthografical and phonological codes; whereas deaf children without cochlear implant use more semantic strategies in reading sentences and orthografical codes. Implications of these results for educational practice are being discussed.

  1. Implant decontamination with phosphoric acid during surgical peri-implantitis treatment : a RCT

    NARCIS (Netherlands)

    Hentenaar, Diederik F M; De Waal, Yvonne C M; Strooker, Hans; Meijer, Henny J A; Van Winkelhoff, Arie-Jan; Raghoebar, Gerry M

    2017-01-01

    BACKGROUND: Peri-implantitis is known as an infectious disease that affects the peri-implant soft and hard tissue. Today, scientific literature provides very little evidence for an effective intervention protocol for treatment of peri-implantitis. The aim of the present randomized controlled trial

  2. A 5-year randomized trial to compare 1 or 2 implants for implant overdentures.

    Science.gov (United States)

    Bryant, S R; Walton, J N; MacEntee, M I

    2015-01-01

    The hypothesis of this 5-y randomized clinical trial was that there would be no significant difference in the satisfaction of edentulous participants with removable complete overdentures attached to 1 or 2 mandibular implants. Secondary aims were to test changes in satisfaction between and within the groups from baseline to 5 y and differences between the groups in implant survival and prosthodontic maintenance over 5 y. Each of the 86 participants (mean age, 67 y) was randomly allocated to receive either 1 implant in the midline (group 1) or 2 implants in the canine areas (group 2) attached to a mandibular overdenture opposing a maxillary complete denture. Satisfaction was self-assessed by participants on a visual analog scale at baseline prior to implants, as well as at 2 mo and 1, 3, and 5 y with implant overdentures, whereas implant survival and prosthodontic maintenance were assessed by clinical examination. After 5 y, 29 participants in group 1 and 33 in group 2 were available, with most dropouts due to death. Satisfaction with the implant denture after 5 y was significantly (P overdentures retained by 1 implant or 2 implants. Additional research is required to confirm long-term treatment effectiveness of single-implant dentures and the implications of prosthetic maintenance with implant overdentures (ClinicalTrials.gov: NCT02117856). © International & American Associations for Dental Research 2014.

  3. Azygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement

    Directory of Open Access Journals (Sweden)

    Naga VA Kommuri

    2010-01-01

    Full Text Available Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.

  4. [Researches on biomechanics of micro-implant-bone interface and optimum design of micro implant's neck].

    Science.gov (United States)

    Deng, Feng; Zhang, Lei; Zhang, Yi; Song, Jin-lin; Fan, Yuboa

    2007-07-01

    To compare and analyze the stress distribution at the micro-implant-bone interface based on the different micro-implant-bone conditioned under orthodontic load, and to optimize the design of micro implant's neck. An adult skull with all tooth was scanned by spiral CT, and the data were imported into computer for three-dimensional reconstruction with software Mimics 9.0. The three dimensional finite element models of three micro-implant-bone interfaces(initial stability, full osseointegration and fibrous integration) were analyzed by finite element analysis software ABAQUS6.5. The primary stress distributions of different micro-implant-bone conditions were evaluated when 2N force was loaded. Then the diameter less than 1.5 mm of the micro implant's neck was added with 0.2 mm, to compare the stress distribution of the modified micro-implant-bone interface with traditional type. The stress mostly concentrated on the neck of micro implant and the full osseointegration interface in all models showed the lowest strain level. Compared with the traditional type, the increasing diameter neck of the micro implant obviously decreased the stress level in all the three conditions. The micro-implant-bone interface and the diameter of micro implant's neck both are the important influence factors to the stress distribution of micro implant.

  5. Primary prevention of peri-implantitis: managing peri-implant mucositis.

    Science.gov (United States)

    Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; Lambert, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni E; Schwarz, Frank; Serino, Giovanni; Tomasi, Cristiano; Zitzmann, Nicola U

    2015-04-01

    Over the past decades, the placement of dental implants has become a routine procedure in the oral rehabilitation of fully and partially edentulous patients. However, the number of patients/implants affected by peri-implant diseases is increasing. As there are--in contrast to periodontitis--at present no established and predictable concepts for the treatment of peri-implantitis, primary prevention is of key importance. The management of peri-implant mucositis is considered as a preventive measure for the onset of peri-implantitis. Therefore, the remit of this working group was to assess the prevalence of peri-implant diseases, as well as risks for peri-implant mucositis and to evaluate measures for the management of peri-implant mucositis. Discussions were informed by four systematic reviews on the current epidemiology of peri-implant diseases, on potential risks contributing to the development of peri-implant mucositis, and on the effect of patient and of professionally administered measures to manage peri-implant mucositis. This consensus report is based on the outcomes of these systematic reviews and on the expert opinion of the participants. Key findings included: (i) meta-analysis estimated a weighted mean prevalence for peri-implant mucositis of 43% (CI: 32-54%) and for peri-implantitis of 22% (CI: 14-30%); (ii) bleeding on probing is considered as key clinical measure to distinguish between peri-implant health and disease; (iii) lack of regular supportive therapy in patients with peri-implant mucositis was associated with increased risk for onset of peri-implantitis; (iv) whereas plaque accumulation has been established as aetiological factor, smoking was identified as modifiable patient-related and excess cement as local risk indicator for the development of peri-implant mucositis; (v) patient-administered mechanical plaque control (with manual or powered toothbrushes) has been shown to be an effective preventive measure; (vi) professional intervention

  6. The Biolink Implantable Telemetry System

    Science.gov (United States)

    Betancourt-Zamora, Rafael J.

    1999-01-01

    Most biotelemetry applications deal with the moderated data rates of biological signals. Few people have studied the problem of transcutaneous data transmission at the rates required by NASA's Life Sciences-Advanced BioTelemetry System (LS-ABTS). Implanted telemetry eliminate the problems associated with wire breaking the skin, and permits experiments with awake and unrestrained subjects. Our goal is to build a low-power 174-216MHz Radio Frequency (RF) transmitter suitable for short range biosensor and implantable use. The BioLink Implantable Telemetry System (BITS) is composed of three major units: an Analog Data Module (ADM), a Telemetry Transmitter Module (TTM), and a Command Receiver Module (CRM). BioLink incorporates novel low-power techniques to implement a monolithic digital RF transmitter operating at 100kbps, using quadrature phase shift keying (QPSK) modulation in the 174-216MHz ISM band. As the ADM will be specific for each application, we focused on solving the problems associated with a monolithic implementation of the TTM and CRM, and this is the emphasis of this report. A system architecture based on a Frequency-Locked Loop (FLL) Frequency Synthesizer is presented, and a novel differential frequency that eliminates the need for a frequency divider is also shown. A self sizing phase modulation scheme suitable for low power implementation was also developed. A full system-level simulation of the FLL was performed and loop filter parameters were determined. The implantable antenna has been designed, simulated and constructed. An implant package compatible with the ABTS requirements is also being proposed. Extensive work performed at 200MHz in 0.5um complementary metal oxide semiconductors (CMOS) showed the feasibility of integrating the RF transmitter circuits in a single chip. The Hajimiri phase noise model was used to optimize the Voltage Controlled Oscillator (VCO) for minimum power consumption. Two test chips were fabricated in a 0.5pm, 3V CMOS

  7. Osteogenesis and Morphology of the Peri-Implant Bone Facing Dental Implants

    Directory of Open Access Journals (Sweden)

    Marco Franchi

    2004-01-01

    Full Text Available This study investigated the influence of different implant surfaces on peri-implant osteogenesis and implant face morphology of peri-implant tissues during the early (2 weeks and complete healing period (3 months. Thirty endosseous titanium implants (conic screws with differently treated surfaces (smooth titanium = SS, titanium plasma sprayed = TPS, sand-blasted zirconium oxide = Zr-SLA were implanted in femur and tibiae diaphyses of two mongrel sheep. Histological sections of the implants and surrounding tissues obtained by sawing and grinding techniques were observed under light microscopy (LM. The peri-implant tissues of other samples were mechanically detached from the corresponding implants to be processed for SEM observation. Two weeks after implantation, we observed osteogenesis (new bone trabeculae around all implant surfaces only where a gap was present at the host bone-metal interface. No evident bone deposition was detectable where threads of the screws were in direct contact with the compact host bone. Distance osteogenesis predominated in SS implants, while around rough surfaces (TPS and Zr-SLA, both distance and contact osteogenesis were present. At SEM analysis 2 weeks after implantation, the implant face of SS peri-implant tissue showed few, thin, newly formed, bone trabeculae immersed in large, loose, marrow tissue with blood vessels. Around the TPS screws, the implant face of the peri-implant tissue was rather irregular because of the rougher metal surface. Zr-SLA screws showed more numerous, newly formed bone trabeculae crossing marrow spaces and also needle-like crystals in bone nodules indicating an active mineralising process. After 3 months, all the screws appeared osseointegrated, being almost completely covered by a compact, mature, newly formed bone. However, some marrow spaces rich in blood vessels and undifferentiated cells were in contact with the metal surface. By SEM analysis, the implant face of the peri-implant

  8. RadConEd: A Graphical Data Editor for the Radiological Consequences Model, RadCon

    International Nuclear Information System (INIS)

    Crawford, J.; Domel, R.U.

    2000-05-01

    This document describes the application, RadConEd, which has been designed and implemented to enable users of the RadCon system to update these parameter files. The RadCon system is written in the Java programming language, and as such provides portability across computer platforms. The software described in this report was developed in line with the portability requirements of RadCon, thus providing a uniform user interface across computer platforms and bypassing the need of using system editors. In addition a number of data integrity measures were implemented

  9. CT evaluation of preoperative cochlear implantation cochlear implantation

    International Nuclear Information System (INIS)

    Tan Xiuzhong; Zhong Lansheng; Lan Bowen; Huang Yaosheng; Du Baowen; Zhu Jian

    2004-01-01

    Objective: To evaluate CT scan as a preoperative evaluation for cochlear implantation candidates. Methods: Axial high-resolution temporal bone CT and three-dimensional reconstruction of inner ear were performed in 93 patients with sensorineural hearing loss. results: Among 81 patients with congenital sensorineural deafness, Mondini malformation was seen in 7 case (13 ears); large vestibular aqueduct syndrome (LVAS) was revealed in 5 cases (8 ears); and inner ear ossification was found in 1 case (2 ears). In 1 case (2 ears) of inner ear fibrosis, reduced cochlear signal was noted on MRI but no unremarkable findings was shown on CT scan, however, in the operation, the device could not inserted into the basal circle of the cochlea, due to fibrous obliteration. In 12 patients with post-speech deafness, chronic suppurative tympanitis was seen in 2 cases (4 ears), and inner ear ossification was revealed in 1 case (2 ears). Conclusion: CT plays an indispensable role in the pre-operative evaluation of cochlear implantation. T 2 -weighted FSE-MRI of the inner ear is a useful complementary to CT scan. (authors)

  10. TH-B-204-01: Real-Time Tracking with Implanted Markers

    International Nuclear Information System (INIS)

    Xu, Q.

    2016-01-01

    Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRI compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant

  11. TH-B-204-02: Application of Implanted Markers in Proton Therapy

    International Nuclear Information System (INIS)

    Park, S.

    2016-01-01

    Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRI compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant

  12. TH-B-204-03: TG-199: Implanted Markers for Radiation Treatment Verification

    International Nuclear Information System (INIS)

    Wang, Z.

    2016-01-01

    Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRI compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant

  13. TH-B-204-00: Implanted Markers for Radiation Therapy and TG 199 Update

    International Nuclear Information System (INIS)

    2016-01-01

    Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRI compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant

  14. TH-B-204-03: TG-199: Implanted Markers for Radiation Treatment Verification

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Z. [Duke University Medical Center (United States)

    2016-06-15

    Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRI compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant

  15. TH-B-204-01: Real-Time Tracking with Implanted Markers

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Q. [MD Anderson Cancer Center at Cooper (United States)

    2016-06-15

    Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRI compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant

  16. TH-B-204-02: Application of Implanted Markers in Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Park, S. [McLaren-Flint, Flint, MI (United States)

    2016-06-15

    Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRI compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant

  17. TH-B-204-00: Implanted Markers for Radiation Therapy and TG 199 Update

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRI compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant

  18. Forming controlled inset regions by ion implantation and laser bombardment

    International Nuclear Information System (INIS)

    Gibbons, J.F.

    1981-01-01

    A semiconductor integrated circuit structure in which the inset regions are ion implanted and laser annealed to maintain substantially the dimensions of the implantation and the method of forming inset implanted regions having controlled dimensions

  19. Effects of elevated ambient temperature on embryo implantation in rats

    African Journals Online (AJOL)

    Yomi

    2012-03-22

    Mar 22, 2012 ... ambient temperature leads to a delayed implantation and reduced number of implantation sites in. Sprague ... rates decrease after exposure to stress. One of the ..... implantation initiation time, support the previous findings.

  20. Facoemulsificación e implante de lente intraocular en cataratas causadas por uveitis Phacoemulsification and intraocular lens implantation in patients with cataract caused by uveitis

    Directory of Open Access Journals (Sweden)

    Dayamí Pérez Gómez

    2008-06-01

    Full Text Available OBJETIVO: Evaluar los resultados de la facoemulsificación y el implante de lente intraocular en cataratas causadas por uveítis. MÉTODOS: Se estudiaron 37 ojos con 6 meses de inactividad inflamatoria, agudeza visual menor de 0,6 y edad media de 47 años. Se excluyeron otras enfermedades que disminuyeran la visión. En el preoperatorio se prescribió antiinflamatorios. Se realizó la facoemulsificación con implante de lente intarocular (PMMA, óptica 6 mm; durante el seguimiento desde 24 h/6 meses se indicó antiinflamatorios esteroideos, no esteroideos e inmunosupresores hasta 6 semanas. RESULTADOS: Se observaron numerosas alteraciones del segmento anterior secundarias a las uveítis padecidas (posquirúrgicas, inespecíficas, ciclítis heterocrómica de Fuchs, postraumáticas, síndrome de Reiter, por toxoplasmosis y otras coroiditis infecciosas y por artritis reumatoide juvenil. No hubo recurrencia posquirúrgica de la uveítis en 9 ojos (24,3 %. Las complicaciones estuvieron relacionadas con la uveítis, la cirugía, la actividad inflamatoria, y la reacción del epitelio capsular. La opacidad capsular posterior apareció en 11 pacientes (29,7 % asociada a edad joven. La evolución individual se consideró satisfactoria en 30 (81,1 % pacientes con mejoría de la visión hasta 0,8-1,0 en 28 (75,6 % y 0,5-0,6 en 2 (5,4 %. CONCLUSIONES: La facoemulsificación con implante de lente intarocular es de gran utilidad en las cataratas posuveítis al condicionar poca agresión quirúrgica, ser controlable la inflamación y proporcionar buenos resultados visuales además del reordenamiento anatomofisiológico del segmento anterior.OBJECTIVE: To assess the results of phacoemulsification and intraocular lens implantation in cataracts caused by uveitis. METHODS: Thirty seven eyes with no inflammation for 6 months, visual acuity below 0.6 and average age of 47 years were studied. Other diseases affecting the vision were excluded. The preoperative

  1. Positron implantation profile in kapton

    International Nuclear Information System (INIS)

    Plotkowski, K.; Panek, T.J.; Kansj, J.

    1988-01-01

    Measurements of positrons' implantation profile were made with geometry as in the majority of PAT experiments, making use of the difference in values of mean lifetimes of positrons in the absorber and in the detector. The function describing the absorption of positrons in the absorber taking into account measurement geometry was fitted to the experimental data. The correction to the exponential relation occurring in this function is the dominating factor for small thicknesses of the absorber. In this analysis various values of positrons' backscatter coefficients of the nickel and of the kapton were also taken into account

  2. Optimal Implantable Cardioverter Defibrillator Programming.

    Science.gov (United States)

    Shah, Bindi K

    Optimal programming of implantable cardioverter defibrillators (ICDs) is essential to appropriately treat ventricular tachyarrhythmias and to avoid unnecessary and inappropriate shocks. There have been a series of large clinical trials evaluating tailored programming of ICDs. We reviewed the clinical trials evaluating ICD therapies and detection, and the consensus statement on ICD programming. In doing so, we found that prolonged ICD detection times, higher rate cutoffs, and antitachycardia pacing (ATP) programming decreases inappropriate and painful therapies in a primary prevention population. The use of supraventricular tachyarrhythmia discriminators can also decrease inappropriate shocks. Tailored ICD programming using the knowledge gained from recent ICD trials can decrease inappropriate and unnecessary ICD therapies and decrease mortality.

  3. Fracture dynamics in implanted silicon

    Energy Technology Data Exchange (ETDEWEB)

    Massy, D.; Tardif, S.; Penot, J. D.; Ragani, J.; Rieutord, F. [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, INAC-SP2M, F-38000 Grenoble (France); Mazen, F.; Madeira, F. [Univ. Grenoble Alpes, F-38000 Grenoble (France); CEA, LETI, MINATEC Campus, F-38054 Grenoble (France); Landru, D.; Kononchuk, O. [SOITEC, Parc Technologique des Fontaines, 38190 Bernin (France)

    2015-08-31

    Crack propagation in implanted silicon for thin layer transfer is experimentally studied. The crack propagation velocity as a function of split temperature is measured using a designed optical setup. Interferometric measurement of the gap opening is performed dynamically and shows an oscillatory crack “wake” with a typical wavelength in the centimetre range. The dynamics of this motion is modelled using beam elasticity and thermodynamics. The modelling demonstrates the key role of external atmospheric pressure during crack propagation. A quantification of the amount of gas trapped inside pre-existing microcracks and released during the fracture is made possible, with results consistent with previous studies.

  4. Amorphisation during elevated temperature implantation

    International Nuclear Information System (INIS)

    Carter, G.; Nobes, M.J.; Elliman, R.G.

    1994-01-01

    Transition state theory is employed to predict the rates of amorphous zone recrystallization by direct thermal and radiation mediated thermal annealing processes. These rates are functions of zone radius and are employed to describe the competition between amorphous zone generation and annealing during elevated temperature heavy ion implantation of, particularly, Si and the accumulation of amorphousness with increasing ion fluence. This analysis predicts a change from monotonic to sigmoidal to biexponential accumulation functions with increasing annealing rate or substrate temperature in agreement with experiments. A logarithmic dependence of ion flux density upon substrate temperature for the achievement of defined fractional amorphisation is predicted and is also in agreement with the experiment. (author)

  5. Sacroiliac joint stability: Finite element analysis of implant number, orientation, and superior implant length.

    Science.gov (United States)

    Lindsey, Derek P; Kiapour, Ali; Yerby, Scott A; Goel, Vijay K

    2018-03-18

    To analyze how various implants placement variables affect sacroiliac (SI) joint range of motion. An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the SI joint using various placement configurations of triangular implants (iFuse Implant System ® ). Placement configurations were varied by changing implant orientation, superior implant length, and number of implants. The range of motion of the SI joint was calculated using a constant moment of 10 N-m with a follower load of 400 N. The changes in motion were compared between the treatment groups to assess how the different variables affected the overall motion of the SI joint. Transarticular placement of 3 implants with superior implants that end in the middle of the sacrum resulted in the greatest reduction in range of motion (flexion/extension = 73%, lateral bending = 42%, axial rotation = 72%). The range of motions of the SI joints were reduced with use of transarticular orientation (9%-18%) when compared with an inline orientation. The use of a superior implant that ended mid-sacrum resulted in median reductions of (8%-14%) when compared with a superior implant that ended in the middle of the ala. Reducing the number of implants, resulted in increased SI joint range of motions for the 1 and 2 implant models of 29%-133% and 2%-39%, respectively, when compared with the 3 implant model. Using a validated finite element model we demonstrated that placement of 3 implants across the SI joint using a transarticular orientation with superior implant reaching the sacral midline resulted in the most stable construct. Additional clinical studies may be required to confirm these results.

  6. Enfermedad coronaria en pacientes con psoriasis

    Directory of Open Access Journals (Sweden)

    Walter Masson

    2013-10-01

    Full Text Available Comunicaciones previas asociaron la psoriasis con la enfermedad coronaria. Desconocemos si en nuestro país o región existe dicha asociación. Se realizó un estudio transversal analizando los datos de la historia clínica electrónica de un sistema de salud de Buenos Aires. Analizamos todos los pacientes mayores de 18 años con diagnóstico de psoriasis entre el 1 de enero de 2003 y el 31 de julio de 2011 y los comparamos con un grupo control, en una relación 2:1, obtenido en forma aleatoria del mismo sistema de salud, apareados por edad y sexo. Determinamos la prevalencia de los factores de riesgo cardiovascular y de enfermedad coronaria. Analizamos la asociación entre la enfermedad coronaria y la psoriasis mediante análisis uni y multivariado. Se incluyeron 3 833 sujetos (1 286 pacientes con psoriasis y 2 547 controles. La prevalencia de hipertensión arterial (50% vs. 38%, p < 0.001, tabaquismo (25% vs. 17%, p < 0.001, diabetes (12% vs. 8%, p < 0.001 y enfermedad coronaria (4.98% vs. 3.06%, p = 0.003 fue mayor en los sujetos con psoriasis en comparación con el grupo control. Independientemente de la edad, la presencia de diabetes, hipertensión arterial o tabaquismo, hubo una asociación significativa entre la enfermedad coronaria y la psoriasis (OR 1.48, IC95% 1.04-2.11, p = 0.03. En conclusión, en esta población de Buenos Aires, los pacientes con psoriasis tuvieron una mayor prevalencia de diabetes, hipertensión arterial, tabaquismo y enfermedad coronaria. La asociación entre la psoriasis y la enfermedad coronaria fue independiente de los factores de riesgo explorados.

  7. Mincle Signaling Promotes Con-A Hepatitis

    Science.gov (United States)

    Greco, Stephanie H.; Torres-Hernandez, Alejandro; Kalabin, Aleksandr; Whiteman, Clint; Rokosh, Rae; Ravirala, Sushma; Ochi, Atsuo; Gutierrez, Johana; Salyana, Muhammad Atif; Mani, Vishnu R.; Nagaraj, Savitha V.; Deutsch, Michael; Seifert, Lena; Daley, Donnele; Barilla, Rocky; Hundeyin, Mautin; Nikifrov, Yuriy; Tejada, Karla; Gelb, Bruce E.; Katz, Steven C.; Miller, George

    2016-01-01

    Concanavalin-A (Con-A) hepatitis is regarded as a T cell-mediated model of acute liver injury. Mincle is a C-type lectin receptor (CLR) that is critical in the immune response to mycobacteria and fungi, but does not have a well-defined role in pre-clinical models of non-pathogen mediated inflammation. Since Mincle can ligate the cell death ligand SAP130, we postulated that Mincle signaling drives intrahepatic inflammation and liver injury in Con-A hepatitis. Acute liver injury was assessed in the murine Con-A hepatitis model using C57BL/6, Mincle−/−, and Dectin-1−/− mice. The role of C/EBPβ and HIF-1α signaling was assessed using selective inhibitors. We found that Mincle was highly expressed in hepatic innate inflammatory cells and endothelial cells in both mice and humans. Furthermore, sterile Mincle ligands and Mincle signaling intermediates were increased in the murine liver in Con-A hepatitis. Most significantly, Mincle deletion or blockade protected against Con-A hepatitis whereas Mincle ligation exacerbated disease. Bone marrow chimeric and adoptive transfer experiments suggested that Mincle signaling in infiltrating myeloid cells dictates disease phenotype. Conversely, signaling via other CLRs did not alter disease course. Mechanistically, we found that Mincle blockade decreased the NF-κβ related signaling intermediates, C/EBPβ and HIF-1α, both of which are necessary in macrophage-mediated inflammatory responses. Accordingly, Mincle deletion lowered production of nitrites in Con-A hepatitis and inhibition of both C/EBPβ and HIF1-α reduced the severity of liver disease. Our work implicates a novel innate immune driver of Con-A hepatitis and, more broadly, suggests a potential role for Mincle in diseases governed by sterile inflammation. PMID:27559045

  8. Mincle Signaling Promotes Con A Hepatitis.

    Science.gov (United States)

    Greco, Stephanie H; Torres-Hernandez, Alejandro; Kalabin, Aleksandr; Whiteman, Clint; Rokosh, Rae; Ravirala, Sushma; Ochi, Atsuo; Gutierrez, Johana; Salyana, Muhammad Atif; Mani, Vishnu R; Nagaraj, Savitha V; Deutsch, Michael; Seifert, Lena; Daley, Donnele; Barilla, Rocky; Hundeyin, Mautin; Nikifrov, Yuriy; Tejada, Karla; Gelb, Bruce E; Katz, Steven C; Miller, George

    2016-10-01

    Con A hepatitis is regarded as a T cell-mediated model of acute liver injury. Mincle is a C-type lectin receptor that is critical in the immune response to mycobacteria and fungi but does not have a well-defined role in preclinical models of non-pathogen-mediated inflammation. Because Mincle can ligate the cell death ligand SAP130, we postulated that Mincle signaling drives intrahepatic inflammation and liver injury in Con A hepatitis. Acute liver injury was assessed in the murine Con A hepatitis model using C57BL/6, Mincle(-/-), and Dectin-1(-/-) mice. The role of C/EBPβ and hypoxia-inducible factor-1α (HIF-1α) signaling was assessed using selective inhibitors. We found that Mincle was highly expressed in hepatic innate inflammatory cells and endothelial cells in both mice and humans. Furthermore, sterile Mincle ligands and Mincle signaling intermediates were increased in the murine liver in Con A hepatitis. Most significantly, Mincle deletion or blockade protected against Con A hepatitis, whereas Mincle ligation exacerbated disease. Bone marrow chimeric and adoptive transfer experiments suggested that Mincle signaling in infiltrating myeloid cells dictates disease phenotype. Conversely, signaling via other C-type lectin receptors did not alter disease course. Mechanistically, we found that Mincle blockade decreased the NF-κβ-related signaling intermediates C/EBPβ and HIF-1α, both of which are necessary in macrophage-mediated inflammatory responses. Accordingly, Mincle deletion lowered production of nitrites in Con A hepatitis and inhibition of both C/EBPβ and HIF-1α reduced the severity of liver disease. Our work implicates a novel innate immune driver of Con A hepatitis and, more broadly, suggests a potential role for Mincle in diseases governed by sterile inflammation. Copyright © 2016 by The American Association of Immunologists, Inc.

  9. Ion implantation as an efficient surface treatment

    International Nuclear Information System (INIS)

    Straede, C.A.

    1992-01-01

    Ion beam processing has for several years been well established in the semiconductor industry. In recent years ion implantation of tool steels, ceramics and even plastics has gained increasing industrial awareness. The development of ion implantation to a commercially viable surface treatment of tools and spare parts working in production type environments is very dependent on technical merits, economic considerations, competing processes and highly individual barriers to acceptance for each particular application. Some examples of this will be discussed. The development of the process is very closely linked with the development of high current accelerators and their ability to efficiently manipulate the samples being treated, or to make sample manipulation superfluous by using special beam systems like the PSII. Furthermore, the ability to produce high beam currents (mA) of a wide variety of ions is crucial. Previously, it was broadly accepted that ion implantation of tools on a commercial basis generally had to be limited to nitrogen implantation. The development of implanters which can produce high beam currents of ions like B + , C + , Ti + , Cr + and others is rapidly changing this situation, and today an increasing number of commercial implantations are performed with these ions although nitrogen is still successfully used in the majority of commercial implantation. All in all, the recent development of equipment makes it possible to a higher extent than before to tailor the implantation to a specific situation. The emerging new possibilities in this direction will be discussed, and a broad selection of practical examples of ion implantation at standard low temperatures of tools and spare parts will be given. Furthermore, very interesting results have been obtained recently by implanting nitrogen at elevated temperatures, which yields a relatively deep penetration of the implanted ions. (orig./WL)

  10. Tinnitus and Sleep Difficulties After Cochlear Implantation.

    Science.gov (United States)

    Pierzycki, Robert H; Edmondson-Jones, Mark; Dawes, Piers; Munro, Kevin J; Moore, David R; Kitterick, Pádraig T

    To estimate and compare the prevalence of and associations between tinnitus and sleep difficulties in a sample of UK adult cochlear implant users and those identified as potential candidates for cochlear implantation. The study was conducted using the UK Biobank resource, a population-based cohort of 40- to 69-year olds. Self-report data on hearing, tinnitus, sleep difficulties, and demographic variables were collected from cochlear implant users (n = 194) and individuals identified as potential candidates for cochlear implantation (n = 211). These "candidates" were selected based on (i) impaired hearing sensitivity, inferred from self-reported hearing aid use and (ii) impaired hearing function, inferred from an inability to report words accurately at negative signal to noise ratios on an unaided closed-set test of speech perception. Data on tinnitus (presence, persistence, and related distress) and on sleep difficulties were analyzed using logistic regression models controlling for gender, age, deprivation, and neuroticism. The prevalence of tinnitus was similar among implant users (50%) and candidates (52%; p = 0.39). However, implant users were less likely to report that their tinnitus was distressing at its worst (41%) compared with candidates (63%; p = 0.02). The logistic regression model suggested that this difference between the two groups could be explained by the fact that tinnitus was less persistent in implant users (46%) compared with candidates (72%; p reported difficulties with sleep were similar among implant users (75%) and candidates (82%; p = 0.28), but participants with tinnitus were more likely to report sleep difficulties than those without (p explanation is supported by the similar prevalence of sleep problems among implant users and potential candidates for cochlear implantation, despite differences between the groups in tinnitus persistence and related emotional distress. Cochlear implantation may therefore not be an appropriate intervention

  11. Utilización de implantes oseointegrados orales para prótesis orbitaria: Caso clínico

    Directory of Open Access Journals (Sweden)

    Gonzalo Borgia

    Full Text Available Resumen: La constante evolución de la Implantología en los últimos años, ha logrado que el implante oseointegrado, sea un medio de anclaje eficaz y seguro, para las prótesis buco-maxilo-faciales. Los altos índices de éxito, que surgen de los estudios clínicos, confirman que los implantes oseointegrados son el tratamiento de elección para determinados pacientes1. El objetivo de este trabajo es la presentación de un caso clínico, en el que se instalaron implantes orales, para anclaje de una prótesis orbitaria. El paciente fue atendido en la Facultad de Odontología de la Universidad de la República, en el Servicio de Prótesis Buco Maxilo Facial, conjuntamente con el Departamento de Implantología Oral y MaxiloFacial

  12. Early implant-associated osteomyelitis results in a peri-implanted bacterial reservoir

    DEFF Research Database (Denmark)

    Jensen, Louise Kruse; Koch, Janne; Aalbæk, Bent

    2017-01-01

    weight of Staphylococcus aureus or saline was inserted into the right tibial bone of 12 pigs. The animals were consecutively killed on day 2, 4 and 6 following implantation. Bone tissue around the implant was histologically evaluated. Identification of S. aureus was performed immunohistochemically...... on tissue section and with scanning electron microscopy and peptide nucleic acid in situ hybridization on implants. The distance of the peri-implanted pathological bone area (PIBA), measured perpendicular to the implant, was significantly larger in infected animals compared to controls (p = 0...

  13. CLINICAL CONSIDERATIONS OF DENTAL IMPLANT SYSTEM IN IMMEDIATE LOADING IMPLANT CASES

    Directory of Open Access Journals (Sweden)

    Carolina Damayanti Marpaung

    2015-06-01

    Full Text Available Immediate loading of dental implant has been researched intensively in the development of Branemark’s early concept of 2 stages implant placement. This was embarked from both patients and practiitioner’s convenience towards a simpler protocol and shorter time frame. Many recent researchers later found that micromotions derived from occlusal loading for a certain degree, instead of resulting a fibrous tissue encapsulation, can enhance the osseointegration process. Dental Implant system enhancement towards maximizing the primary stability held a key factor in Branemark’s concept development. Surgical protocol and implant design was found to give a significant contribution to the prognosis of immediate-loading implants.

  14. Variables socionutricionales de hogares mazahuas integrados por preescolares desnutridos con madres con obesidad y sin obesidad

    Directory of Open Access Journals (Sweden)

    Conzuelo González, Viridiana Vanessa

    2009-01-01

    Full Text Available El primer objetivo fue conocer cuántos menores de cinco años con diferentes grados de desnutrición tienen una madre con sobrepeso/obesidad/ en una comunidad indígena que vive en extrema pobreza y bajo condiciones de migración masculina internacional. El segundo fue comparar tres variables socionutricionales (ingreso familiar, educación de la madre y adecuación nutrimental de la dieta diaria entre estos hogares y los hogares con desnutrición infantil y madres sin obesidad. Se realizó un estudio transversal (2006-2007, en la comunidad mazahua de San Francisco Tepeolulco, Municipio de Temascalcingo; que incluyó a 85 hogares integrados por preescolares con desnutrición inscritos al programa Oportunidades. Se determinó el estado nutrición de los preescolares con indicadores antropométricos y se obtuvo el IMC de las madres de estos infantes. Se aplicó una encuesta socionutricional, incluida el recordatorio de 24 horas, y complementado con la observación participante (cualitativa. Se encontró que 83% de las madres mazahuas presentaron sobrepeso u obesidad. El estado de nutrición de los preescolares con madres con obesidad presentó un porcentaje mayor de desnutrición (76%. En la variable género, se encontró que 54% de los niños con madres con obesidad tenía baja talla. Al relacionar el nivel educativo de la madre, esta variable resultó ser estadísticamente significativa (p=0.015, donde el analfabetismo está más relacionado con la desnutrición infantil que tienen madres de bajo y/o peso normal. La elevada prevalencia de hogares conformados con preescolares con desnutrición y madres con obesidad, es un síntoma más de la pobreza en zonas indígenas en México, con bajo índice de desarrollo humano.

  15. Importancia del tratamiento ortodóncico en la efectividad de los implantes dentales

    Directory of Open Access Journals (Sweden)

    Isabel Cristina Díaz Acosta

    Full Text Available Los implantes osteointegrados permite recuperar de forma fija y cómoda todas las funciones del diente perdido. El objetivo de esta presentación es demostrar los beneficios de realizar tratamientos ortodóncico previos a la colocación de implantes dentales en pacientes edentes. Un paciente de 21 años acudió a consulta de implantología en la Clínica Estomatológica Provincial Docente “Dr. Ismael Clark y Mascaró” de Camagüey, por ausencia de incisivos central y lateral superior derecho (11 y 12. Se valoró por el equipo multidisciplinario, el cual planteó cerrar el espacio de la brecha edente con aparatología ortodóncica fija y después realizar cirugía de avanzada y la colocación de un implante Leader Nano. La rehabilitación protésica se realizó a los ocho meses. Se demostró la eficacia de la realización de tratamiento ortodóncico previo a la colocación de implantes dentales así como el restablecimiento del estado estético y psicológico del paciente.

  16. Epilepsia de la infancia con paroxismos occipitales

    Directory of Open Access Journals (Sweden)

    Albia Pozo Alonso

    1999-09-01

    Full Text Available Se reporta que la epilepsia de la infancia con paroxismos occipitales constituye un síndrome epiléptico muy bien definido; se incluye en el grupo de las epilepsias idiopáticas relacionadas con localización. Los ataques comienzan habitualmente con síntomas visuales, en ocasiones seguidos por ataques hemiclónicos, parciales complejos y tónicoclónicos generalizados. El electroencefalograma interictal muestra complejos de puntaonda de localización occipital y temporal posterior que desaparecen con la apertura de los ojos. Se presenta una paciente de 8 años de edad que reúne los criterios clínicos y electroencefalográficos de la epilepsia de la infancia con paroxismos occipitales y se enfatiza en la evolución supuestamente benigna de dicho síndrome.Is is reported that epilepsy of childhood with occipital paroxysms is an epileptic syndrome that is well defined. It is included in the group of related idiopathic epilepsies with localization. Seizures habitually begin with visual symptoms, which are ocassionally followed by hemiclonic, complex partial, and generalized tonicclonic seizures. The interictal EEG shows spike-wave complexes of occipital and temporal posterior localization that are suppressed by eye opening. A patient aged 8 in whom the clinical and electroencephalographic criteria of epilepsy of childhood with occipital paroxysms are present is studied in this paper. Emphasis is made on the apparently benign evolution of this syndrome.

  17. Novel implant design improves implant survival in multirooted extraction sites: a preclinical pilot study.

    Science.gov (United States)

    Sivan-Gildor, Adi; Machtei, Eli E; Gabay, Eran; Frankenthal, Shai; Levin, Liran; Suzuki, Marcelo; Coelho, Paulo G; Zigdon-Giladi, Hadar

    2014-10-01

    The primary aim is to evaluate clinical, radiographic, and histologic parameters of novel implants with "three roots" design that were inserted into fresh multirooted extraction sockets. A secondary aim is to compare this new implant to standard root-form dental implants. Immediate implantation of novel or standard design 6 × 6-mm implants was performed bilaterally into multirooted sockets in mandibles of mini-pigs. Twelve weeks later, clinical, radiographic, stability, histomorphometric, and microcomputed tomography (micro-CT) analyses were performed. Survival rates were significantly higher in the test implants compared with control (92.8% versus 33.3%, respectively; P micro-CT analyses demonstrated bone fill in the inner part of the test implants. Moreover, bone-to-implant contact was higher in the test implants (55.50% ± 3.68% versus 42.47% ± 9.89%). Contrary to the clinical, radiographic, and histomorphometric results, resonance frequency analysis measurements were greater in the control group (77.74 ± 3.21 implant stability quotient [ISQ]) compared with the test group (31.09 ± 0.28 ISQ), P = 0.008. The novel design implants resulted in significantly greater survival rate in multirooted extraction sites. Further studies will be required to validate these findings.

  18. Influence of prosthesis design and implantation technique on implant stresses after cementless revision THR

    Directory of Open Access Journals (Sweden)

    Duda Georg N

    2011-05-01

    Full Text Available Abstract Background Femoral offset influences the forces at the hip and the implant stresses after revision THR. For extended bone defects, these forces may cause considerable bending moments within the implant, possibly leading to implant failure. This study investigates the influences of femoral anteversion and offset on stresses in the Wagner SL revision stem implant under varying extents of bone defect conditions. Methods Wagner SL revision stems with standard (34 mm and increased offset (44 mm were virtually implanted in a model femur with bone defects of variable extent (Paprosky I to IIIb. Variations in surgical technique were simulated by implanting the stems each at 4° or 14° of anteversion. Muscle and joint contact forces were applied to the reconstruction and implant stresses were determined using finite element analyses. Results Whilst increasing the implant's offset by 10 mm led to increased implant stresses (16.7% in peak tensile stresses, altering anteversion played a lesser role (5%. Generally, larger stresses were observed with reduced bone support: implant stresses increased by as much as 59% for a type IIIb defect. With increased offset, the maximum tensile stress was 225 MPa. Conclusion Although increased stresses were observed within the stem with larger offset and increased anteversion, these findings indicate that restoration of offset, key to restoring joint function, is unlikely to result in excessive implant stresses under routine activities if appropriate fixation can be achieved.

  19. Reparación protésica de hernias inguinales con técnica de Lichtenstein

    Directory of Open Access Journals (Sweden)

    Ernesto Simón Enríquez Weinmann

    2003-03-01

    Full Text Available Se presentan los resultados de un estudio prospectivo que trata de la colocación de prótesis por vía anterior en la reparación de hernias inguinales con la utilización de variantes técnicas propuestas por Lichtenstein. Se incluye un total de 150 pacientes, a los que se les realizó operación, desde septiembre de 1996 hasta febrero de 2001; en 100 de éstos se practicó la técnica de reforzamiento protésico inicialmente descrita por Lichtenstein, y en 50, la técnica libre de tensión. Se realizaron 93 herniorrafias primarias, y 57 en hernias recidivadas, 10 de ellas iteradas. El tipo de hernia más frecuentemente operado según la clasificación de Gilbert modificada, fue la tipo III; 8 pacientes presentaban hernia en pantalón (tipo VI. La anestesia más frecuentemente usada fue la regional, y le siguió en frecuencia la anestesia general, local y analgesia acupuntural. Las complicaciones se comportaron de manera similar a las técnicas tradicionales, donde 26 pacientes presentaron complicaciones inmediatas menores. Ocurrió sepsis de la herida en un caso (0,6 %, y hasta la fecha no se han verificado recidivas, con un seguimiento promedio de 39 meses (12-66 del 100 % de los casos. Se sustenta la enseñanza del reforzamiento protésico para el cirujano en formaciónThe results of a prospective study dealing with the placement of prostheses by anterior route in the repair of inguinal hernias by using the technical variants proposed by Lichtenstein were presented. 150 patients who were operated on from September, 1996, to February, 2001, were included. The prosthetic reinforcement technique initially described by Lichtenstein was performed in 100, whereas the free-tension technique was used in 50 patients. 93 primary herniorraphies were performed. 57 were carried out in recurrent hernias, 10 of them iterated. Type III was the type of hernia most commonly operated on, according to Gilbert classification. 8 patients presented type VI hernia

  20. Long range implantation by MEVVA metal ion source

    International Nuclear Information System (INIS)

    Zhang Tonghe; Wu Yuguang; Ma Furong; Liang Hong

    2001-01-01

    Metal vapor vacuum arc (MEVVA) source ion implantation is a new technology used for achieving long range ion implantation. It is very important for research and application of the ion beam modification of materials. The results show that the implanted atom diffusion coefficient increases in Mo implanted Al with high ion flux and high dose. The implanted depth is 311.6 times greater than that of the corresponding ion range. The ion species, doses and ion fluxes play an important part in the long-range implantation. Especially, thermal atom chemistry have specific effect on the long-range implantation during high ion flux implantation at transient high target temperature

  1. Martensite transformation in antimony implanted stainless steel

    International Nuclear Information System (INIS)

    Johnson, E.; Littmark, U.; Johansen, A.; Christodoulides, C.

    1981-01-01

    The authors have used Rutherford backscattering analysis (RBS) and transmission electron microscopy (TEM) and diffraction to investigate austenitic stainless steel crystals implanted at room temperature with 80 keV Sb + ions to a fluence of 5 x 10 20 ions/m 2 , thus providing implantation with a heavy group V element. RBS channeling spectra from implanted crystals show a damage peak which approaches the height of the random level and therefore indicates a very high degree of disorder in the implanted layers. The distribution of the disorder extends to a depth 3-5 times the depth of the primary radiation damage. The Sb peaks under channeling as well as random conditions are indistinguishable, confirming that substitutionality during implantation is negligible. To establish the nature of the disorder which cannot be assessed from the RBS analysis alone, and in particular to assess whether an amorphous alloy is formed in the implanted layer as indicated from the RBS spectra, samples implanted under similar conditions were investigated in the TEM. Significant extra spots in the patterns can be ascribed to the presence of a radiation induced b.c.c. phase of martensitic origin. The result that a significant amount of martensite can be induced by antimony implantation seems to indicate that the main driving force for the transition is due to damage induced stress concentrations. (Auth.)

  2. Laser annealing of ion implanted silicon

    International Nuclear Information System (INIS)

    White, C.W.; Narayan, J.; Young, R.T.

    1978-11-01

    The physical and electrical properties of ion implanted silicon annealed with high powered ruby laser radiation are summarized. Results show that pulsed laser annealing can lead to a complete removal of extended defects in the implanted region accompanied by incorporation of dopants into lattice sites even when their concentration far exceeds the solid solubility limit

  3. Thermal behaviour of nitrogen implanted into zirconium

    International Nuclear Information System (INIS)

    Miyagawa, S.; Ikeyama, M.; Saitoh, K.; Nakao, S.; Niwa, H.; Tanemura, S.; Miyagawa, Y.

    1994-01-01

    Zirconium films were implanted with 15 N ions of energy 50keV to a total fluence of 1x10 18 ionscm -2 in an attempt to study the formation process and thermal stability of ZrN layers produced by high fluence implantation of nitrogen. Subsequent to the implantation at room temperature, samples were annealed at temperatures of 300 C-900 C. The depth profiles of the implanted nitrogen were measured by nuclear reaction analysis using the 15 N(p,αγ) 12 C at E R =429keV, and the surfaces were examined by thin film X-ray diffraction (XRD) and scanning electron microscopy. There were many blisters 0.2-0.4μm in diameter on the surface of the as-implanted samples and double peaks were observed in the nitrogen depth profiles; they were in both sides of the mean projected range. It was found that most of the blisters became extinct after annealing above 400 C, and the XRD peak (111) intensity was increased with the increase in the annealing temperature. Moreover, 14 N and 15 N implantations were superimposed on Zr samples in order to study the atomic migration of nitrogen at each stage of high fluence implantation. It was found that the decrease in the peak at the deeper layers was related to blister extinction and nitrogen diffusion into underling zirconium which could be correlated with radiation damage induced by post-implanted ions. ((orig.))

  4. Magnetoreflection studies of ion implanted bismuth

    International Nuclear Information System (INIS)

    Nicolini, C.; Chieu, T.C.; Dresselhaus, M.S.; Massachusetts Inst. of Tech., Cambridge; Dresselhaus, G.

    1982-01-01

    The effect of the implantation of Sb ions on the electronic structure of the semimetal bismuth is studied by the magnetoreflection technique. The results show long electronic mean free paths and large implantation-induced increases in the band overlap and L-point band gap. These effects are opposite to those observed for Bi chemically doped with Sb. (author)

  5. Wireless Power Transfer Strategies for Implantable Bioelectronics.

    Science.gov (United States)

    Agarwal, Kush; Jegadeesan, Rangarajan; Guo, Yong-Xin; Thakor, Nitish V

    2017-01-01

    Neural implants have emerged over the last decade as highly effective solutions for the treatment of dysfunctions and disorders of the nervous system. These implants establish a direct, often bidirectional, interface to the nervous system, both sensing neural signals and providing therapeutic treatments. As a result of the technological progress and successful clinical demonstrations, completely implantable solutions have become a reality and are now commercially available for the treatment of various functional disorders. Central to this development is the wireless power transfer (WPT) that has enabled implantable medical devices (IMDs) to function for extended durations in mobile subjects. In this review, we present the theory, link design, and challenges, along with their probable solutions for the traditional near-field resonant inductively coupled WPT, capacitively coupled short-ranged WPT, and more recently developed ultrasonic, mid-field, and far-field coupled WPT technologies for implantable applications. A comparison of various power transfer methods based on their power budgets and WPT range follows. Power requirements of specific implants like cochlear, retinal, cortical, and peripheral are also considered and currently available IMD solutions are discussed. Patient's safety concerns with respect to electrical, biological, physical, electromagnetic interference, and cyber security from an implanted neurotech device are also explored in this review. Finally, we discuss and anticipate future developments that will enhance the capabilities of current-day wirelessly powered implants and make them more efficient and integrable with other electronic components in IMDs.

  6. Libyan cochlear implant programme: achievements, difficulties, and ...

    African Journals Online (AJOL)

    Data relating to the patients who received cochlear implantation at Tripoli Medical Centre between October 2007 and February 2010 were analysed. Implant operations were performed on 37 patients. All patients received Med-El SONATATI100 devices. Thirty-four (91.9%) of these patients were children, whilst three (8.1%) ...

  7. Dental implants: A boon to dentistry

    Directory of Open Access Journals (Sweden)

    B H Sripathi Rao

    2015-01-01

    Full Text Available The development and use of implants is one of the biggest advances in dentistry in the last few decades. It has helped to give many solutions to tooth loss as well as maxillo facial prosthetics. This article traces the history and evolution of dental implants.

  8. Wettability control of polystyrene by ion implantation

    International Nuclear Information System (INIS)

    Suzuki, Yoshiaki; Kusakabe, Masahiro; Iwaki, Masaya

    1994-01-01

    The permanent effects of ion implantation on the improvement of wettability of polystyrene is investigated in relation to ion species and fluences. The He + , Ne + , Na + , N 2 + , O 2 + , Ar + , K + and Kr + ion implantations were performed at energies of 50 and 150 keV at room temperature. The fluences ranged from 1x10 15 to 1x10 17 ions/cm 2 . The results showed that the contact angle of water for Na + and K + implanted polystyrene decreased from 87 to 0 , as the fluences increased to 1x10 17 ions/cm 2 at an energy of 50 keV. The contact angle for Na + and K + implanted polystyrene did not change under ambient room conditions, even when time elapsed. However, the contact an gle for He + , C + , O + , Ne + , N 2 + , O 2 + , Ar + , and Kr + ion implanted specimens decreased slightly immediately after ion implantation. Results of X-ray photoelectron spectroscopy showed that the increase in the Na content in the surface of Na + implanted specimens were observed with increasing fluence. It is concluded that permanent improvement in wettability was caused by doping effects rather than by radiation effects from Na + and K + ion implantation. ((orig.))

  9. Electroconvulsive therapy after maxillofacial metallic implants.

    Science.gov (United States)

    Freeman, G Mark; Perry, Matthew T; Manatt, George S; Cristancho, Pilar

    2014-03-01

    A growing body of literature suggests that electroconvulsive therapy (ECT) can be safely utilized in patients with craniofacial metallic implants. Here we provide radiographic images and the clinical course of a 49-year-old woman with both maxillary and mandibular metallic implants who safely received ECT.

  10. Biomimetic implants for pelvic floor repair

    NARCIS (Netherlands)

    Vashaghian, Mahshid; Zaat, Sebastianus A. J.; Smit, Theodoor H.; Roovers, Jan-Paul

    2017-01-01

    Polypropylene implants are used for the reconstructive surgery of urogynaecological disorders like pelvic organ prolapse, but severe complications associated with their use have been reported. There is evidence that surface properties and a difference in mechanical stiffness between the implant and

  11. Oral Abstract Session 3: Orthognathic/Implants

    DEFF Research Database (Denmark)

    Hartlev, Jens

    Immediate Placement And Provisionalization Of Single-tooth Implants Involving A Final Individual Abutment. A 3-year Clinical And Radiographic Retrospektive Study......Immediate Placement And Provisionalization Of Single-tooth Implants Involving A Final Individual Abutment. A 3-year Clinical And Radiographic Retrospektive Study...

  12. Biofilm and dental implant: The microbial link

    Directory of Open Access Journals (Sweden)

    Sangeeta Dhir

    2013-01-01

    Full Text Available Mouth provides a congenial environment for the growth of the microorganisms as compared to any other part of the human body by exhibiting an ideal nonshedding surface. Dental plaque happens to be a diverse community of the microorganisms found on the tooth surface. Periodontal disease and the peri-implant disease are specific infections that are originating from these resident microbial species when the balance between the host and the microbial pathogenicity gets disrupted. This review discusses the biofilms in relation to the peri-implant region, factors affecting its presence, and the associated treatment to manage this complex microbial colony. Search Methodology: Electronic search of the medline was done with the search words: Implants and biofilms/dental biofilm formation/microbiology at implant abutment interface/surface free energy/roughness and implant, periimplantitis/local drug delivery and dental implant. Hand search across the journals - clinical oral implant research, implant dentistry, journal of dental research, international journal of oral implantology, journal of prosthetic dentistry, perioodntology 2000, journal of periodontology were performed. The articles included in the review comprised of in vivo studies, in vivo (animal and human studies, abstracts, review articles.

  13. Simplifying cochlear implant speech processor fitting

    NARCIS (Netherlands)

    Willeboer, C.

    2008-01-01

    Conventional fittings of the speech processor of a cochlear implant (CI) rely to a large extent on the implant recipient's subjective responses. For each of the 22 intracochlear electrodes the recipient has to indicate the threshold level (T-level) and comfortable loudness level (C-level) while

  14. Osseoperception in Dental Implants: A Systematic Review.

    Science.gov (United States)

    Mishra, Sunil Kumar; Chowdhary, Ramesh; Chrcanovic, Bruno Ramos; Brånemark, Per-Ingvar

    2016-04-01

    Replacement of lost teeth has significant functional and psychosocial effects. The capability of osseointegrated dental implants to transmit a certain amount of sensibility is still unclear. The phenomenon of developing a certain amount of tactile sensibility through osseointegrated dental implants is called osseoperception. The aim of this article is to evaluate the available literature to find osseoperception associated with dental implants. To identify suitable literature, an electronic search was performed using Medline and PubMed database. Articles published in English and articles whose abstract is available in English were included. The articles included in the review were based on osseoperception, tactile sensation, and neurophysiological mechanoreceptors in relation to dental implants. Articles on peri-implantitis and infection-related sensitivity were not included. Review articles without the original data were excluded, although references to potentially pertinent articles were noted for further follow-up. The phenomenon of osseoperception remains a matter of debate, so the search strategy mainly focused on articles on osseoperception and tactile sensibility of dental implants. This review presents the histological, neurophysiological, and psychophysical evidence of osseoperception and also the role of mechanoreceptors in osseoperception. The literature on osseoperception in dental implants is very scarce. The initial literature search resulted in 90 articles, of which 81 articles that fulfilled the inclusion criteria were included in this systematic review. Patients restored with implant-supported prostheses reported improved tactile and motor function when compared with patients wearing complete dentures. © 2016 by the American College of Prosthodontists.

  15. Polymeric implant of methylprednisolone for spinal injury ...

    African Journals Online (AJOL)

    Polymeric implant of methylprednisolone for spinal injury: preparation and characterization. Bo Yin, Jian-Jun Ji, Ming Yang. Abstract. Purpose: To improve the effectiveness and reduce the systemic side effects of methylprednisolone in traumatic spinal injuries, its polymeric implants were prepared using chitosan and sodium ...

  16. Systemic Assessment of Patients Undergoing Dental Implant ...

    African Journals Online (AJOL)

    Background: Procedure‑related and patient‑related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty‑one patients were included in the study, in which a total of 110 dental ...

  17. Systemic Assessment of Patients Undergoing Dental Implant ...

    African Journals Online (AJOL)

    These days, dental implants are becoming routinely used as a treatment option for rehabilitation of lost teeth. Conventionally, it is only after the completion of bone healing that the dental implants are loaded into the bone. Bone healing time is approximately 3 months and. 6 months for the mandible and maxilla, respectively.

  18. Different encapsulation strategies for implanted electronics

    Directory of Open Access Journals (Sweden)

    Winkler Sebastian

    2017-09-01

    Full Text Available Recent advancements in implant technology include increasing application of electronic systems in the human body. Hermetic encapsulation of electronic components is necessary, specific implant functions and body environments must be considered. Additional functions such as wireless communication systems require specialized technical solutions for the encapsulation.

  19. Physical Properties of Silicone Gel Breast Implants.

    Science.gov (United States)

    Jewell, Mark L; Bengtson, Bradley P; Smither, Kate; Nuti, Gina; Perry, TracyAnn

    2018-04-28

    Surgical applications using breast implants are individualized operations to fill and shape the breast. Physical properties beyond shape, size, and surface texture are important considerations during implant selection. Compare form stability, gel material properties, and shell thickness of textured shaped, textured round, and smooth round breast implants from 4 manufacturers: Allergan, Mentor, Sientra, and Establishment Labs through bench testing. Using a mandrel height gauge, form stability was measured by retention of dimensions on device movement from a horizontal to vertical supported orientation. Dynamic response of gel material (gel cohesivity, resistance to gel deformation, energy absorption) was measured using a synchronized target laser following application of graded negative pressure. Shell thickness was measured using digital thickness gauge calipers. Form stability, gel material properties, and shell thickness differed across breast implants. Of textured shaped devices, Allergan Natrelle 410 exhibited greater form stability than Mentor MemoryShape and Sientra Shaped implants. Allergan Inspira round implants containing TruForm 3 gel had greater form stability, higher gel cohesivity, greater resistance to gel deformation, and lower energy absorption than those containing TruForm 2 gel and in turn, implants containing TruForm 1 gel. Shell thickness was greater for textured versus smooth devices, and differed across styles. Gel cohesivity, resistance to gel deformation, and energy absorption are directly related to form stability, which in turn determines shape retention. These characteristics provide information to aid surgeons choosing an implant based on surgical application, patient tissue characteristics, and desired outcome.

  20. Quality assessment of pacemaker implantations in Denmark

    DEFF Research Database (Denmark)

    Møller, M; Arnsbo, P; Asklund, Mogens

    2002-01-01

    AIMS: Quality assessment of therapeutic procedures is essential to insure a cost-effective health care system. Pacemaker implantation is a common procedure with more than 500,000 implantations world-wide per year, but the general complication rate is not well described. We studied procedure relat...