WorldWideScience

Sample records for injection lab-on-valve si-lov

  1. Determination of trace metal ions via on-line separation and preconcentration by means of chelating Sepharose beads in a sequential injection lab-on-valve (SI-LOV) system coupled to electrothermal atomic absorption spectrometric detection

    DEFF Research Database (Denmark)

    Long, Xiangbao; Hansen, Elo Harald; Miró, Manuel

    2005-01-01

    The analytical performance of an on-line sequential injection lab-on-valve (SI-LOV) system using chelating Sepharose beads as sorbent material for the determination of ultra trace levels of Cd(II), Pb(II) and Ni(II) by electrothermal atomic absorption spectrometry (ETAAS) is described and discussed...

  2. Evaluation of a novel PTFE material for separation and preconcentration of trace levels of metal ions in sequential injection (SI) and sequential injection lab-on-valve (SI-LOV) systems interfaced with detection by ETAAS

    DEFF Research Database (Denmark)

    Long, Xiangbao; Chomchoei, Roongrat; Gała, Piotr

    The operational characteristics of a novel PTFE bead material, granular Algoflon®, used for separation and preconcentration of metal ions via adsorption of on-line generated non-charged metal complexes, were evaluated in a sequential injection (SI) system furnished with an external packed column...... and in a sequential injection lab-on-valve (SI-LOV) system. Employed for the determination of cadmium(II), complexed with diethyldithiophosphate (DDPA), and detection by electrothermal atomic absorption spectrometry (ETAAS), its performance was compared to that of a previously used material, Aldrich PTFE, which had...... demonstrated that PTFE was the most promising for solid-state pretreatments. By comparing the two materials, the Algoflon® beads exhibited much higher sensitivity (1.6107 versus 0.2956 μg l-1 per integrated absorbance (s)), and better retention efficiency (82% versus 74%) and enrichment factor (20.8 versus 17...

  3. Evaluation of a novel PTFE material for use as a means for separation and preconcentration of trace levels of metal ions in sequential injection (SI) and sequential injection lab-on-valve (SI-LOV) systems. Determination of cadmium (II) with detection by electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Long, Xiangbao; Chomchoei, Roongrat; Hansen, Elo Harald

    2004-01-01

    with an external packed column and in a sequential injection lab-on-valve (SI-LOV) system. Employed for the determination of cadmium(II), complexed with diethyldithiophosphate (DDPA), and detection by electrothermal atomic absorption spectrometry (ETAAS), its performance was compared to that of a previously used...

  4. Highly selective micro-sequential injection lab-on-valve (muSI-LOV) method for the determination of ultra-trace concentrations of nickel in saline matrices using detection by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Long, Xiangbao; Miró, Manuel; Jensen, Rikard; Hansen, Elo Harald

    2006-10-01

    A highly selective procedure is proposed for the determination of ultra-trace level concentrations of nickel in saline aqueous matrices exploiting a micro-sequential injection Lab-On-Valve (muSI-LOV) sample pretreatment protocol comprising bead injection separation/pre-concentration and detection by electrothermal atomic absorption spectrometry (ETAAS). Based on the dimethylglyoxime (DMG) reaction used for nickel analysis, the sample, as contained in a pH 9.0 buffer, is, after on-line merging with the chelating reagent, transported to a reaction coil attached to one of the external ports of the LOV to assure sufficient reaction time for the formation of Ni(DMG)(2) chelate. The non-ionic coordination compound is then collected in a renewable micro-column packed with a reversed-phase copolymeric sorbent [namely, poly(divinylbenzene-co-N-vinylpyrrolidone)] containing a balanced ratio of hydrophilic and lipophilic monomers. Following elution by a 50-muL methanol plug in an air-segmented modality, the nickel is finally quantified by ETAAS. Under the optimized conditions and for a sample volume of 1.8 mL, a retention efficiency of 70 % and an enrichment factor of 25 were obtained. The proposed methodology showed a high tolerance to the commonly encountered alkaline earth matrix elements in environmental waters, that is, calcium and magnesium, and was successfully applied for the determination of nickel in an NIST standard reference material (NIST 1640-Trace elements in natural water), household tap water of high hardness and local seawater. Satisfying recoveries were achieved for all spiked environmental water samples with maximum deviations of 6 %. The experimental results for the standard reference material were not statistically different to the certified value at a significance level of 0.05.

  5. Sequential injection lab-on-valve: the third generation of flow injection analysis

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2003-01-01

    Termed the third generation of flow injection analysis, sequential injection (SI)-lab-on-valve (LOV) has specific advantages and allows novel, unique applications - not least as a versatile front end to a variety of detection techniques. This review presents snd discusses progress to date of the ...

  6. Extraction and preconcentration of trace levels of cobalt using functionalized magnetic nanoparticles in a sequential injection lab-on-valve system with detection by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Wang Yang; Luo Xiaoyu; Tang Jie; Hu Xiaoya; Xu Qin; Yang Chun

    2012-01-01

    Graphical abstract: An approach to performing extraction and preconcentration employing functionalized magnetic particles for the determination of cobalt in the sequential injection lab-on-valve system using detection by electrothermal atomic absorption spectrometry. Highlights: ► New SPE method for cobalt separation/preconcentration was reported. ► Functionalized magnetic nanoparticles were used as adsorbent. ► Extraction, elution, and detection procedures were performed in the LOV system. ► This automatic extraction technique provided a good platform for metal analysis. - Abstract: A new approach to performing extraction and preconcentration employing functionalized magnetic nanoparticles for the determination of trace metals is presented. Alumina-coated iron oxide nanoparticles were synthesized and used as the solid support. The nanoparticles were functionalized with sodium dodecyl sulfate and used as adsorbents for solid phase extraction of the analyte. Extraction, elution, and detection procedures were performed sequentially in the sequential injection lab-on-valve (SI-LOV) system followed by electrothermal atomic absorption spectrometry (ETAAS). Mixtures of hydrophobic analytes were successfully extracted from solution using the synthesized magnetic adsorbents. The potential use of the established scheme was demonstrated by taking cobalt as a model analyte. Under the optimal conditions, the calibration curve showed an excellent linearity in the concentration range of 0.01–5 μg L −1 , and the relative standard deviation was 2.8% at the 0.5 μg L −1 level (n = 11). The limit of detection was 6 ng L −1 with a sampling frequency of 18 h −1 . The present method has been successfully applied to cobalt determination in water samples and two certified reference materials.

  7. A Universal Approach for Selective Trace Metal Determinations via Sequential Injection-Bead Injection-Lab-on-Valve (SI-BI-LOV) Using Renewable Reagent-loaded Hydrophobic Beads

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald

    -Lab-on-Valve (SI-LOV) mode. The methodology uses poly(styrene-divinylbenzene) beads containing pendant octadecyl moieties (C18-PS/DVB), which are pre-impregnated with a selective organic metal chelating agent prior to the automatic manipulation of the beads in the microbore conduits of the LOV unit. By adapting...

  8. New Trends in Flow Injection Analysis: Exploitation of Sequential and Lab-on-Valve Schemes

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    has appeared, that is, the Lab-on-Valve (LOV) approach, the conceptual basis of which is to incorporate all the necessary unit operational manipulations required, and, when possible, even the detection device into a single small integrated microconduit, or “laboratory”, placed atop a selection valve...... sensitivity and selectivity. Either in order to separate/preconcentrate the analyte material, or because of the presence of potentially interfering matrix constituents. Such pretreatments are advantageously performed in FIA/SIA/LOV manifolds, where all appropriate unit operations can be effected under...

  9. Determination of Low Level Concentrations of Metals by Means of Sequential Injection (SI) and Lab-on-Valve (LOV) Methodologies

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    packed with suitable materials, the emphasis in this lecture will be on applying solid-phase extraction in the SI/LOV mode. Providing unique characteristics and specific advantages, particularly allowing to take advantage of the so-called renewable approach, where the solid-phase material, if called for...

  10. Determination of Low Level Concentrations of Metals by Means of Sequential Injection (SI) and Lab-on-Valve (LOV) Methodologies

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Miró, Manuel; Petersen, Roongrat

    /emission spectrometry (FAAS, ETAAS, ICP-AES, ICP-MS). The lecture will initially give an overview of various automated alternatives for facilitating appropriate SI/LOV-separation and pre-concentration schemes of metals in liquid samples, including examples of solid-phase extraction with permanent columns or renewable...

  11. Recent developments in automated determinations of trace level concentrations of elements and on-line fractionations schemes exploiting the micro-sequential injection - lab-on-valve approach

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Miró, Manuel; Long, Xiangbao

    2006-01-01

    The determination of trace level concentrations of elements, such as metal species, in complex matrices by atomic absorption or emission spectrometric methods often require appropriate pretreatments comprising separation of the analyte from interfering constituents and analyte preconcentration...... are presented as based on the exploitation of micro-sequential injectionSI-LOV) using hydrophobic as well as hydrophilic bead materials. The examples given comprise the presentation of a universal approach for SPE-assays, front-end speciation of Cr(III) and Cr(VI) in a fully automated and enclosed set...

  12. Bead Injection Extraction Chromatography using High-capacity Lab-on-Valve as a Front End to Inductively Coupled Plasma Mass Spectrometry for Rapid Urine Radiobioassay

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2013-01-01

    A novel bead injection (BI) extraction chromatographic microflow system exploiting high-capacity lab-on-valve (LOV) platform coupled with inductively coupled plasma mass spectrometric detection is developed for rapid and automated determination of plutonium in human urine. A microconduit (1 m......L) incorporated within the LOV processing unit is loaded on-line with a metered amount of disposable extraction chromatographic resin (up to 330 mg of TEVA) through programmable beads transport. Selective capture and purification of plutonium onto the resin beads is then performed by pressure driven flow after...

  13. Micro solid phase spectrophotometry in a sequential injection lab-on-valve platform for cadmium, zinc, and copper determination in freshwaters

    International Nuclear Information System (INIS)

    Santos, Inês C.; Mesquita, Raquel B.R.; Rangel, António O.S.S.

    2015-01-01

    This work describes the development of a solid phase spectrophotometry method in a μSI-LOV system for cadmium, zinc, and copper determination in freshwaters. NTA (Nitrilotriacetic acid) beads with 60–160 μm diameter were packed in the flow cell of the LOV for a μSPE column of 1 cm length. The spectrophotometric determination is based on the colourimetric reaction between dithizone and the target metals, previously retained on NTA resin. The absorbance of the coloured product formed is measured, at 550 nm, on the surface of the NTA resin beads in a solid phase spectrophotometry approach. The developed method presented preconcentration factors in the range of 11–21 for the metal ions. A LOD of 0.23 μg L"−"1 for cadmium, 2.39 μg L"−"1 for zinc, and 0.11 μg L"−"1 for copper and a sampling rate of 12, 13, and 15 h"−"1 for cadmium, zinc, and copper were obtained, respectively. The proposed method was successfully applied to freshwater samples. - Highlights: • Multi-parametric determination of cadmium, zinc, and copper at the μg L"−"1 level. • In-line metal ions preconcentration using NTA resin. • Minimization of matrix interferences by performing solid phase spectrometry in a SI-LOV platform. • Successful application to metal ions determination in freshwaters.

  14. Highly selective micro-sequential injection lab-on-valveSI-LOV) method for determination of ultra trace concentrations of nickel in saline matrices using detection by electrothermal atomic absorption spectrometr

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Jensen, Rikard

    2006-01-01

    of the LOV to assure sufficient reaction time for the formation of Ni(DMG)2 chelate. The non-ionic coordination compound is then collected in a renewable micro-column packed with a reversed-phase copolymeric sorbent [namely, poly(divinylbenzene-co-N-vinylpyrrolidone)] containing a balanced ratio...... water of high hardness and local seawater. Satisfying recoveries were achieved for all spiked environmental water samples with maximum deviations of 6%. The experimental results for the standard reference material were not statistically different to the certified value at a significance level of 0.05....

  15. On-line dynamic extraction and automated determination of readily bioavailable hexavalent chromium in solid substrates using micro-sequential injection bead-injection lab-on-valve hyphenated with electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald

    2006-01-01

    A novel and miniaturized micro-sequential injection bead injection lab-on-valve (μSI-BI-LOV) fractionation system was developed for in-line microcolumn soil extraction under simulated environmental scenarios and accurate monitoring of the content of easily mobilisable hexavalent chromium in soil...... environments at the sub-low parts-per-million level. The flow system integrates dynamic leaching of hexavalent chromium using deionized water as recommended by the German Standard DIN 38414-S4 method; on-line pH adjustment of the extract by a 0.01 mol L-1 Tris-HNO3 buffer solution; isolation of the chromate...... polluted agricultural soil material (San Joaquin Soil-Baseline Trace Element Concentrations) with water-soluble Cr(VI) salts at different concentration levels. The potential of the μSI-BI-LOV set-up with renewable surfaces for flame-AAS determination of high levels of readily bioavailable chromate...

  16. Micro solid phase spectrophotometry in a sequential injection lab-on-valve platform for cadmium, zinc, and copper determination in freshwaters

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Inês C. [CBQF–Centro de Biotecnologia e Química Fina – Laboratório Associado, Escola Superior de Biotecnologia, Universidade Católica Portuguesa/Porto, Rua Arquiteto Lobão Vital, Apartado 2511, 4202-401 Porto (Portugal); Mesquita, Raquel B.R. [CBQF–Centro de Biotecnologia e Química Fina – Laboratório Associado, Escola Superior de Biotecnologia, Universidade Católica Portuguesa/Porto, Rua Arquiteto Lobão Vital, Apartado 2511, 4202-401 Porto (Portugal); Laboratório de Hidrobiologia, Instituto de Ciências Biomédicas Abel Salazar (ICBAS), Universidade do Porto, Rua de Jorge Viterbo Ferreira no. 228, 4050-313 Porto (Portugal); Rangel, António O.S.S., E-mail: arangel@porto.ucp.pt [CBQF–Centro de Biotecnologia e Química Fina – Laboratório Associado, Escola Superior de Biotecnologia, Universidade Católica Portuguesa/Porto, Rua Arquiteto Lobão Vital, Apartado 2511, 4202-401 Porto (Portugal)

    2015-09-03

    This work describes the development of a solid phase spectrophotometry method in a μSI-LOV system for cadmium, zinc, and copper determination in freshwaters. NTA (Nitrilotriacetic acid) beads with 60–160 μm diameter were packed in the flow cell of the LOV for a μSPE column of 1 cm length. The spectrophotometric determination is based on the colourimetric reaction between dithizone and the target metals, previously retained on NTA resin. The absorbance of the coloured product formed is measured, at 550 nm, on the surface of the NTA resin beads in a solid phase spectrophotometry approach. The developed method presented preconcentration factors in the range of 11–21 for the metal ions. A LOD of 0.23 μg L{sup −1} for cadmium, 2.39 μg L{sup −1} for zinc, and 0.11 μg L{sup −1} for copper and a sampling rate of 12, 13, and 15 h{sup −1} for cadmium, zinc, and copper were obtained, respectively. The proposed method was successfully applied to freshwater samples. - Highlights: • Multi-parametric determination of cadmium, zinc, and copper at the μg L{sup −1} level. • In-line metal ions preconcentration using NTA resin. • Minimization of matrix interferences by performing solid phase spectrometry in a SI-LOV platform. • Successful application to metal ions determination in freshwaters.

  17. Exploiting the bead-injection approach in the integrated sequential injection Lab-on-Valve format using hydrophobic packing materials for on-line matrix removal and preconcentration of trace levels of cadmium in environmental and biological samples via formation of non-charged chelates prior

    DEFF Research Database (Denmark)

    Miró, Manuel; Jonczyk, Sylwia; Wang, Jianhua

    2003-01-01

    The concept of renewable microcolumns within the conduits of an automated single injection lab-on-valve system was exploited in a sorption/elution fashion using sorbents of hydrophobic nature. The scheme's practical applicability was demonstrated for the electrothermal atomic absorption spectrome......The concept of renewable microcolumns within the conduits of an automated single injection lab-on-valve system was exploited in a sorption/elution fashion using sorbents of hydrophobic nature. The scheme's practical applicability was demonstrated for the electrothermal atomic absorption...

  18. Lab-on-Valve Micro Sequential Injection: A Versatile Approach for Implementing Integrated Sample Pre-preparations and Executing (Bio)Chemical Assays

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    waste generation. Most recently, the socalled third generation of FIA has emerged, that is, the Lab-on-Valve (LOV) approach, the conceptual basis of which is to incorporate all the necessary unit operational manipulations required, and, when possible, even the detection device into a single small...... integrated microconduit, or “laboratory”, placed atop a selection valve. The lecture will detail the evolution of the three generations of FIA, emphasis being placed on the LOV approach. Proven itself as a versatile front end to a variety of detection techniques, its utility will be exemplified by a series...... of the renewable microcolumn concept. Despite their excellent analytical chemical capabilities, ETAAS as well as ICPMS often require that the samples are subjected to suitable pretreatment in order to obtain the necessary sensitivity and selectivity. Either in order to separate the analyte from potentially...

  19. Lab-on-Valve Micro Sequential Injection: A Versatile Approach for Implementing Integrated Sample Pre-preparations and Executing (Bio)Chemical Assays

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    waste generation. Most recently, the Lab-on-Valve (LOV) approach has emerged. Termed the third generation of FIA, the conceptual basis of the LOV is to incorporate all the necessary unit operational manipulations required in a chemical assay, and, when possible, even the detection device, into a single...... small integrated microconduit, or “laboratory”, placed atop a selection valve. In the lecture emphasis will be placed on the LOV approach. Proven itself as a versatile front end to a variety of detection techniques, its utility will be exemplified by various applications. Particular focus......-phase microcolumn concept utilising hydrophobic as well as hydrophilic bead materials. Although ETAAS and ICPMS both are characterised by excellent analytical chemical capabilities, they nevertheless often require that the samples be subjected to suitable pretreatment in order to obtain the necessary sensitivity...

  20. Micro solid phase spectrophotometry in a sequential injection lab-on-valve platform for cadmium, zinc, and copper determination in freshwaters.

    Science.gov (United States)

    Santos, Inês C; Mesquita, Raquel B R; Rangel, António O S S

    2015-09-03

    This work describes the development of a solid phase spectrophotometry method in a μSI-LOV system for cadmium, zinc, and copper determination in freshwaters. NTA (Nitrilotriacetic acid) beads with 60-160 μm diameter were packed in the flow cell of the LOV for a μSPE column of 1 cm length. The spectrophotometric determination is based on the colourimetric reaction between dithizone and the target metals, previously retained on NTA resin. The absorbance of the coloured product formed is measured, at 550 nm, on the surface of the NTA resin beads in a solid phase spectrophotometry approach. The developed method presented preconcentration factors in the range of 11-21 for the metal ions. A LOD of 0.23 μg L(-1) for cadmium, 2.39 μg L(-1) for zinc, and 0.11 μg L(-1) for copper and a sampling rate of 12, 13, and 15 h(-1) for cadmium, zinc, and copper were obtained, respectively. The proposed method was successfully applied to freshwater samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. A LabVIEW®-based software for the control of the AUTORAD platform. A fully automated multisequential flow injection analysis Lab-on-Valve (MSFIA-LOV) system for radiochemical analysis

    International Nuclear Information System (INIS)

    Barbesi, Donato; Vilas, Victor Vicente; Millet, Sylvain; Sandow, Miguel; Colle, Jean-Yves; Heras, Laura Aldave de las

    2017-01-01

    A LabVIEW®-based software for the control of the fully automated multi-sequential flow injection analysis Lab-on-Valve (MSFIA-LOV) platform AutoRAD performing radiochemical analysis is described. The analytical platform interfaces an Arduino®-based device triggering multiple detectors providing a flexible and fit for purpose choice of detection systems. The different analytical devices are interfaced to the PC running LabVIEW®VI software using USB and RS232 interfaces, both for sending commands and receiving confirmation or error responses. The AUTORAD platform has been successfully applied for the chemical separation and determination of Sr, an important fission product pertinent to nuclear waste. (author)

  2. A LabVIEW®-based software for the control of the AUTORAD platform: a fully automated multisequential flow injection analysis Lab-on-Valve (MSFIA-LOV) system for radiochemical analysis.

    Science.gov (United States)

    Barbesi, Donato; Vicente Vilas, Víctor; Millet, Sylvain; Sandow, Miguel; Colle, Jean-Yves; Aldave de Las Heras, Laura

    2017-01-01

    A LabVIEW ® -based software for the control of the fully automated multi-sequential flow injection analysis Lab-on-Valve (MSFIA-LOV) platform AutoRAD performing radiochemical analysis is described. The analytical platform interfaces an Arduino ® -based device triggering multiple detectors providing a flexible and fit for purpose choice of detection systems. The different analytical devices are interfaced to the PC running LabVIEW ® VI software using USB and RS232 interfaces, both for sending commands and receiving confirmation or error responses. The AUTORAD platform has been successfully applied for the chemical separation and determination of Sr, an important fission product pertinent to nuclear waste.

  3. Sequential injection-bead injection-lab-on-valve schemes for on-line solid phase extraction and preconcentration of ultra-trace levels of heavy metals with determination by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Wang Jianhua; Hansen, Elo Harald; Miro, Manuel

    2003-01-01

    This communication presents an overview of the state-of-the-art of the exploitation of sequential injection (SI)-bead injection (BI)-lab-on-valve (LOV) schemes for automatic on-line sample pre-treatments interfaced with ETAAS and ICPMS detection as conducted in the authors' group. The discussions are focused on the applications of SI-BI-LOV protocols for on-line microcolumn based solid phase extraction of ultra-trace levels of heavy metals, employing the so-called renewable surface separation and preconcentration manipulatory scheme. Two types of sorbents have been employed as packing material, that is, the hydrophilic SP Sephadex C-25 cation exchange and iminodiacetate based Muromac A-1 chelating resins, and the hydrophobic poly(tetrafluoroethylene) (PTFE) and poly(styrene-divinylbenzene) copolymer alkylated with octadecyl groups (C 18 -PS/DVB). Using ETAAS as detection device, the easy-to-handle hydrophilic renewable reactors hold the features of improved R.S.D.s and LODs as compared to those operated in the conventional, permanent mode, in addition to the elimination of flow resistance. The hydrophobic columns fall into two categories, that is, the renewable one packed with C 18 -PS/DVB beads entails analogous R.S.D.s and LODs with respect to the conventional approach, while those with PTFE beads result in slightly inferior R.S.D.s and LODs by similar comparison, yet offering a wider dynamic range than when using an external permanent column. Moreover, the hydrophilic materials result in much higher enrichment of the analyte than the hydrophobic ones, although PTFE is the packing material that exhibits the best retention efficiency

  4. Separation and preconcentration of ultratrace levels of cadmium(II) in a sequential injection (SI) system with a PTFE packed column as a mimic sequential injection lab-on-valve (SI-LOV) system with renewable column employing detection by electrothermal atomic absorption spectrometry (ETAAS)

    DEFF Research Database (Denmark)

    Long, Xiangbao; Chomchoei, Roongrat; Gała, Piotr

    of cadmium(II) by detection with electrothermal atomic absorption spectrometry (ETAAS). The non-charged complex formed between the analyste and the chelating reagent diethyldithiophosphate (DDPA) was selectively adsorbed on the surface of the PTFE beads and eluted by ethanol before being directed...

  5. On-line ion exchange preconcentration in a sequential injection lab-on-valve microsystem incorporating a renewable column with ETAAS for the trace-level determination of bismuth in urine and river sediment

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2001-01-01

    A sequential injection system for on-line ion-exchange separation and preconcentration of trace-level amounts of metal ions with ensuing detection by electrothermal atomic absorption spectrometry (ETAAS) is described. Based on the use of a renewable microcolumn incorporated within an integrated l.......3% for the determination of 2.0 mug/l Bi (n = 7). The procedure was validated by determination of bismuth in a certified reference material CRM 320 (river sediment), and by bismuth spike recoveries in two human urine samples....

  6. Towards an automatic lab-on-valve-ion mobility spectrometric system for detection of cocaine abuse.

    Science.gov (United States)

    Cocovi-Solberg, David J; Esteve-Turrillas, Francesc A; Armenta, Sergio; de la Guardia, Miguel; Miró, Manuel

    2017-08-25

    A lab-on-valve miniaturized system integrating on-line disposable micro-solid phase extraction has been interfaced with ion mobility spectrometry for the accurate and sensitive determination of cocaine and ecgonine methyl ester in oral fluids. The method is based on the automatic loading of 500μL of oral fluid along with the retention of target analytes and matrix clean-up by mixed-mode cationic/reversed-phase solid phase beads, followed by elution with 100μL of 2-propanol containing (3% v/v) ammonia, which are online injected into the IMS. The sorptive particles are automatically discarded after every individual assay inasmuch as the sorptive capacity of the sorbent material is proven to be dramatically deteriorated with reuse. The method provided a limit of detection of 0.3 and 0.14μgL -1 for cocaine and ecgonine methyl ester, respectively, with relative standard deviation values from 8 till 14% with a total analysis time per sample of 7.5min. Method trueness was evaluated by analyzing oral fluid samples spiked with cocaine at different concentration levels (1, 5 and 25μgL -1 ) affording relative recoveries within the range of 85±24%. Fifteen saliva samples were collected from volunteers and analysed following the proposed automatic procedure, showing a 40% cocaine occurrence with concentrations ranging from 1.3 to 97μgL -1 . Field saliva samples were also analysed by reference methods based on lateral flow immunoassay and gas chromatography-mass spectrometry. The application of this procedure to the control of oral fluids of cocaine consumers represents a step forward towards the development of a point-of-care cocaine abuse sensing system. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Exploiting the Lab-on-Valve Concept for Determination of Trace Levels of Metals in Complex Matrices with Detection by ETAAS and ICPMS

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Wang, Jianhua

    approach [1,2]. Coupled to detection by ETAAS and ICPMS, and illustrated by recent exploits in the authors’ laboratory, it is shown that this methodology eliminates the problems encountered in conventional on-line column preconcentration systems and at the same time improves the overall operational......Termed the third generation of flow injection analysis, the Sequential Injection (SI)-Lab-on-Valve (LOV) concept has proven to entail specific advantages and to allow novel and unique applications. Both in term of its use in the automation and micro-miniaturization of suitable on-line sample...

  8. Determination of trace zinc in seawater by coupling solid phase extraction and fluorescence detection in the Lab-On-Valve format.

    Science.gov (United States)

    Grand, Maxime M; Chocholouš, Petr; Růžička, Jarda; Solich, Petr; Measures, Christopher I

    2016-06-07

    By virtue of their compactness, long-term stability, minimal reagent consumption and robustness, miniaturized sequential injection instruments are well suited for automation of assays onboard research ships. However, in order to reach the sensitivity and limit of detection required for open-ocean determinations of trace elements, it is necessary to preconcentrate the analyte prior its derivatization and subsequent detection by fluorescence. In this work, a novel method for the determination of dissolved zinc (Zn) at subnanomolar levels in seawater is described. The proposed method combines, for the first time, automated matrix removal, extraction of the target element, and fluorescence detection within a miniaturized flow manifold, based on the Lab-On-Valve (LOV) concept. The key feature of the microfluidic manipulation of the sample is flow programming, designed to pass sample through a mini-column where the target analyte and other complexable cations are retained, while the seawater matrix is washed out. Next, zinc is eluted and merged with a Zn selective fluorescent probe (FluoZin-3) at the confluence point of the LOV central channel using two high-precision stepper motor driven pumps that are operated in concert. Finally, the thus formed Zn complex is transported to the LOV flow cell for selective fluorescence measurement. This work describes the characterization and optimization of the method including Solid Phase Extraction using the Toyopearl AF-Chelate-650M resin, and detailed assay protocol controlled by a commercially available software and instrument. The proposed method features a LOD of 0.02 nM, high precision (seawater reference standards and comparison with ICP-MS determinations on seawater samples collected in the upper 1300 m of the subtropical south Indian Ocean. This work confirms that integration of sample pretreatment with optical detection in the LOV format offers a widely applicable approach to trace analysis of seawater. Copyright © 2016

  9. On-line sample-pre-treatment schemes for trace-level determinations of metals by coupling flow injection or sequential injection with ICP-MS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2003-01-01

    a polytetrafluoroethylene (PTFE) knotted reactor (KR), solvent extraction-back extraction and hydride/vapor generation. It also addresses a novel, robust approach, whereby the protocol of SI-LOV-bead injection (BI) on-line separation and pre-concentration of ultra-trace levels of metals by a renewable microcolumn...

  10. Universal approach for selective trace metal determinations via sequential injection-bead injection-lab-on-valve using renewable hydrophobic bead surfaces as reagent carriers

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald

    2005-01-01

    involves the use of poly(styrene-divinylbenzene) beads containing pendant octadecyl moieties (C18-PS/DVB), which are preimpregnated with a selective organic metal chelating agent prior to the automatic manipulation of the beads in the microbore conduits of the LOV unit. By adapting this approach...

  11. Trends and perspectives of flow injection/sequential injection on-line sample-pretreatment schemes coupled to ETAAS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2005-01-01

    Flow injection (FI) analysis, the first generation of this technique, became in the 1990s supplemented by its second generation, sequential injection (SI), and most recently by the third generation (i.e.,Lab-on-Valve). The dominant role played by FI in automatic, on-line, sample pretreatments in ...

  12. The Impact of Flow Injection on Modern Chemical Analysis

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    and preconcentration procedures. In recent years, FIA has been supplemented by Sequential Injection Analysis (SIA) and the Lab-on-Valve (LOV) approach. Following a brief historic introduction and an account of the impact of FIA in academia, the lecture will describe these two new generations of FIA, accompanied...

  13. Solid reactors in sequential injection analysis: Recent trends in the environmental field

    DEFF Research Database (Denmark)

    Miró, Manuel; Hansen, Elo Harald

    2006-01-01

    -bead injection (SI-BI), used in either the jet-ring or lab-on-valve configurations, is presented as a front-end to many detectors. This article also outlines recent trends focused on exploiting SI as an automated tool for handling solid samples of environmental concern and accommodating dynamic fractionation...

  14. Sequential injection/bead injection lab-on-valve schemes for on-line solid phase extraction and preconcentration of ultra-trace levels of heavy metals with determination by ETAAS and ICPMS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald; Miró, Manuel

    2003-01-01

    are focused on the applications of SI-BI-LOV protocols for on-line microcolumn based solid phase extraction of ultra-trace levels of heavy metals, employing the so-called renewable surface separation and preconcentration manipulatory scheme. Two types of sorbents have been employed as packing material...

  15. Multisyringe flow injection lab-on-valve systems coupled to hydride generation atomic fluorescence spectrometry for on-line bead-injection preconcentration and determination of total inorganic arsenic in environmental waters

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald

    and 10% KI. The eluate merges downstream with a defined plug of sodium tetrahydroborate (0.3% w/v) for generation of arsine, which is subsequently quantified by AFS. An oxidation agent, namely 2x10-6 M potassium permanganate, was employed for the quantitative oxidation of As(III) to As(V) in the samples...

  16. Hyphenating multisyringe flow injection lab-on-valve analysis with atomic fluorescence spectrometry for on-line bead-injection preconcentration and determination of trace levels of hydride-forming elements in environmental samples

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald

    2006-01-01

    the determination of ultratrace level concentrations of total inorganic arsenic in freshwater. Employing quantitative preoxidation of As(III) to As(V) in the samples by means of permanganate, the method involves the preconcentration of arsenate at pH 10 on a renewable anion exchanger, namely Q-Sepharose, packed...

  17. An automatic micro-sequential injection bead injection lab-on-valve (muSI-BI-LOV) assembly for speciation analysis of ultra trace levels of Cr(III) and Cr(VI) incorporating on-line chemical reduction and employing detection by electrothermal atomic absorption spectrometry (ETAAS)

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald

    2005-01-01

    and determination of trace levels of Cr(III) and Cr(VI) in environmental samples. The method was validated by determination of chromium species in CRM and NIST standard reference materials, and by spike recoveries of surface waters. Statistical comparison of means between experimental results and the total chromium...... certified values for the CRM and NIST materials revealed the non-existence of significant differences at a 95% confidence level....

  18. Interfacing microfluidic handling with spectroscopic detection for real-life applications via the lab-on-valve platform: A review

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Miró, Manuel

    2008-01-01

    with syringe pump propelling devices as a front end to a plethora of spectroscopic detection schemes including UV-Vis spectroscopy, spectrofluorimetry, chemiluminescence, AAS, AFS and ICP-AES/MS. In contrast to lab-on-a-chip units, the versatile configuration of the micromachined LOV readily facilitates...

  19. Testosterone Injection

    Science.gov (United States)

    ... typical male characteristics. Testosterone injection works by supplying synthetic testosterone to replace the testosterone that is normally ... as a pellet to be injected under the skin.Testosterone injection may control your symptoms but will ...

  20. Granisetron Injection

    Science.gov (United States)

    Granisetron immediate-release injection is used to prevent nausea and vomiting caused by cancer chemotherapy and to ... nausea and vomiting that may occur after surgery. Granisetron extended-release (long-acting) injection is used with ...

  1. Edaravone Injection

    Science.gov (United States)

    Edaravone injection is used to treat amyotrophic lateral sclerosis (ALS, Lou Gehrig's disease; a condition in which ... die, causing the muscles to shrink and weaken). Edaravone injection is in a class of medications called ...

  2. Meropenem Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria that cause infection.Antibiotics such as meropenem injection will not work for colds, flu, or other viral infections. Taking ...

  3. Chloramphenicol Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by stopping the growth of bacteria..Antibiotics such as chloramphenicol injection will not work for colds, flu, or other viral infections. Taking ...

  4. Colistimethate Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria.Antibiotics such as colistimethate injection will not work for colds, flu, or other viral infections. Using ...

  5. Defibrotide Injection

    Science.gov (United States)

    Defibrotide injection is used to treat adults and children with hepatic veno-occlusive disease (VOD; blocked blood ... the body and then returned to the body). Defibrotide injection is in a class of medications called ...

  6. Nalbuphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using nalbuphine injection, you may experience withdrawal symptoms including restlessness; teary eyes; runny nose; yawning; ...

  7. On-line liquid phase micro-extraction based on drop-in-plug sequential injection lab-at-valve platform for metal determination

    Energy Technology Data Exchange (ETDEWEB)

    Mitani, Constantina [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124 (Greece); Anthemidis, Aristidis N., E-mail: anthemid@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124 (Greece)

    2013-04-10

    Highlights: ► Drop-in-plug micro-extraction based on SI-LAV platform for metal preconcentration. ► Automatic liquid phase micro-extraction coupled with FAAS. ► Organic solvents with density higher than water are used. ► Lead determination in environmental water and urine samples. -- Abstract: A novel automatic on-line liquid phase micro-extraction method based on drop-in-plug sequential injection lab-at-valve (LAV) platform was proposed for metal preconcentration and determination. A flow-through micro-extraction chamber mounted at the selection valve was adopted without the need of sophisticated lab-on-valve components. Coupled to flame atomic absorption spectrometry (FAAS), the potential of this lab-at-valve scheme is demonstrated for trace lead determination in environmental and biological water samples. A hydrophobic complex of lead with ammonium pyrrolidine dithiocarbamate (APDC) was formed on-line and subsequently extracted into an 80 μL plug of chloroform. The extraction procedure was performed by forming micro-droplets of aqueous phase into the plug of the extractant. All critical parameters that affect the efficiency of the system were studied and optimized. The proposed method offered good performance characteristics and high preconcentration ratios. For 10 mL sample consumption an enhancement factor of 125 was obtained. The detection limit was 1.8 μg L{sup −1} and the precision expressed as relative standard deviation (RSD) at 50.0 μg L{sup −1} of lead was 2.9%. The proposed method was evaluated by analyzing certified reference materials and applied for lead determination in natural waters and urine samples.

  8. Subcutaneous Injections

    DEFF Research Database (Denmark)

    Thomsen, Maria

    This thesis is about visualization and characterization of the tissue-device interaction during subcutaneous injection. The tissue pressure build-up during subcutaneous injections was measured in humans. The insulin pen FlexTouchr (Novo Nordisk A/S) was used for the measurements and the pressure ...

  9. Hydromorphone Injection

    Science.gov (United States)

    ... anyone else to use your medication. Store hydromorphone injection in a safe place so that no one else can use it accidentally or on purpose. Keep track of how much medication is left so ... with hydromorphone injection may increase the risk that you will develop ...

  10. Ketorolac Injection

    Science.gov (United States)

    ... an older adult, you should know that ketorolac injection is not as safe as other medications that can be used to treat your condition. Your doctor may choose to prescribe a different medication ... to ketorolac injection.Your doctor or pharmacist will give you the ...

  11. Paclitaxel Injection

    Science.gov (United States)

    (pak'' li tax' el)Paclitaxel injection must be given in a hospital or medical facility under the supervision of a doctor who is experienced in giving chemotherapy medications for cancer.Paclitaxel injection may cause a large decrease in the number of white blood cells (a type of blood cell ...

  12. Temozolomide Injection

    Science.gov (United States)

    ... balance or coordination fainting dizziness hair loss insomnia memory problems pain, itching, swelling, or redness in the place where the medication was injected changes in vision Some side effects can be serious. If you ...

  13. Buprenorphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opiate partial agonists. It works to prevent withdrawal symptoms ... help. If the victim has collapsed, had a seizure, has trouble breathing, or can't be awakened, ...

  14. Risperidone Injection

    Science.gov (United States)

    ... release (long-acting) injection is used to treat schizophrenia (a mental illness that causes disturbed or unusual ... may help control your symptoms but will not cure your condition. Continue to keep appointments to receive ...

  15. Haloperidol Injection

    Science.gov (United States)

    ... haloperidol extended-release injection are used to treat schizophrenia (a mental illness that causes disturbed or unusual ... may help control your symptoms but will not cure your condition. Continue to keep appointments to receive ...

  16. Omalizumab Injection

    Science.gov (United States)

    ... injection is used to decrease the number of asthma attacks (sudden episodes of wheezing, shortness of breath, and ... about how to treat symptoms of a sudden asthma attack. If your asthma symptoms get worse or if ...

  17. Injection Tests

    CERN Document Server

    Kain, V

    2009-01-01

    The success of the start-up of the LHC on 10th of September was in part due to the preparation without beam and injection tests in 2008. The injection tests allowed debugging and improvement in appropriate portions to allow safe, efficient and state-of-the-art commissioning later on. The usefulness of such an approach for a successful start-up becomes obvious when looking at the problems we encountered before and during the injection tests and could solve during this period. The outline of the preparation and highlights of the different injection tests will be presented and the excellent performance of many tools discussed. A list of shortcomings will follow, leading to some planning for the preparation of the run in 2009.

  18. Cefotaxime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefotaxime injection will not work for colds, flu, or other viral infections. Using ...

  19. Cefuroxime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefuroxime injection will not work for colds, flu, or other viral infections. Using ...

  20. Doripenem Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as doripenem injection will not work for colds, flu, or other viral infections. Taking ...

  1. Daptomycin Injection

    Science.gov (United States)

    ... in a class of medications called cyclic lipopeptide antibiotics. It works by killing bacteria.Antibiotics such as daptomycin injection will not work for treating colds, flu, or other viral infections. ...

  2. Ceftaroline Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftaroline injection will not work for colds, flu, or other viral infections. Using ...

  3. Aztreonam Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as aztreonam injection will not work for colds, flu, or other viral infections. Taking ...

  4. Cefazolin Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefazolin injection will not work for colds, flu, or other viral infections. Taking ...

  5. Ceftazidime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftazidime injection will not work for colds, flu, or other viral infections. Using ...

  6. Cefotetan Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefotetan injection will not work for colds, flu, or other viral infections. Using ...

  7. Cefoxitin Injection

    Science.gov (United States)

    ... is in a class of medications called cephamycin antibiotics. It works by killing bacteria.Antibiotics such as cefoxitin injection will not work for colds, flu, or other viral infections. Taking ...

  8. Tigecycline Injection

    Science.gov (United States)

    ... is in a class of medications called tetracycline antibiotics. It works by killing bacteria that cause infection.Antibiotics such as tigecycline injection will not work for colds, flu, or other viral infections. Using ...

  9. Ertapenem Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as ertapenem injection will not work for colds, flu, or other viral infections. Taking ...

  10. Ceftriaxone Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftriaxone injection will not work for colds, flu, or other viral infections.Using ...

  11. Cefepime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefepime injection will not work for colds, flu, or other viral infections. Using ...

  12. Telavancin Injection

    Science.gov (United States)

    ... is in a class of medications called lipoglycopeptide antibiotics. It works by killing bacteria that cause infection.Antibiotics such as telavancin injection will not work for colds, flu, or other viral infections. Using ...

  13. Doxycycline Injection

    Science.gov (United States)

    ... is in a class of medications called tetracycline antibiotics. It works by killing bacteria that cause infections.Antibiotics such as doxycycline injection will not work for colds, flu, or other viral infections. Taking ...

  14. Vancomycin Injection

    Science.gov (United States)

    ... is in a class of medications called glycopeptide antibiotics. It works by killing bacteria that cause infections.Antibiotics such as vancomycin injection will not work for colds, flu, or other viral infections. Taking ...

  15. Octreotide Injection

    Science.gov (United States)

    ... carton and protect it from light. Dispose of multi-dose vials of the immediate-release injection 14 ... and immediately place the medication in a safe location – one that is up and away and out ...

  16. Moxifloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using moxifloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  17. Delafloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using delafloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  18. Levofloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using levofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  19. Ciprofloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using ciprofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  20. Alirocumab Injection

    Science.gov (United States)

    ... 9 (PCSK9) inhibitor monoclonal antibodies. It works by blocking the production of LDL cholesterol in the body ... hives difficulty breathing or swallowing swelling of the face, throat, tongue, lips, and eyes Alirocumab injection may ...

  1. Evolocumab Injection

    Science.gov (United States)

    ... 9 (PCSK9) inhibitor monoclonal antibody. It works by blocking the production of LDL cholesterol in the body ... hives difficulty breathing or swallowing swelling of the face, throat, tongue, lips, and eyes Evolocumab injection may ...

  2. Acyclovir Injection

    Science.gov (United States)

    ... It is also used to treat first-time genital herpes outbreaks (a herpes virus infection that causes sores ... in the body. Acyclovir injection will not cure genital herpes and may not stop the spread of genital ...

  3. Butorphanol Injection

    Science.gov (United States)

    ... Butorphanol is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using butorphanol injection, you may experience withdrawal symptoms such as nervousness, agitation, shakiness, diarrhea, chills, ...

  4. Micro-bead injection spectroscopy for label-free automated determination of immunoglobulin G in human serum.

    Science.gov (United States)

    Ramos, Inês I; Magalhães, Luís M; Barreiros, Luisa; Reis, Salette; Lima, José L F C; Segundo, Marcela A

    2018-01-01

    Immunoglobulin G (IgG) represents the major fraction of antibodies in healthy adult human serum, and deviations from physiological levels are a generic marker of disease corresponding to different pathologies. Therefore, screening methods for IgG evaluation are a valuable aid to diagnostics. The present work proposes a rapid, automatic, and miniaturized method based on UV-vis micro-bead injection spectroscopy (μ-BIS) for the real-time determination of human serum IgG with label-free detection. Relying on attachment of IgG in rec-protein G immobilized in Sepharose 4B, a bioaffinity column is automatically assembled, where IgG is selectively retained and determined by on-column optical density measurement. A "dilution-and-shoot" approach (50 to 200 times) was implemented without further sample treatment because interferences were flushed out of the column upon sample loading, with minimization of carryover and cross-contamination by automatically discarding the sorbent (0.2 mg) after each determination. No interference from human serum albumin at 60 mg mL -1 in undiluted sample was found. The method allowed IgG determination in the range 100-300 μg mL -1 (corresponding to 5.0-60 mg mL -1 in undiluted samples), with a detection limit of 33 μg mL -1 (1.7 mg mL -1 for samples, dilution factor of 50). RSD values were time-to-result decreased from several hours to times, showing the potential of the proposed approach as a point-of-care method. Graphical abstract Micro-Bead Injection Spectroscopy method for real time, automated and label-free determination of total serum human Immunoglobulin G (IgG). The method was designed for Lab-on-Valve (LOV) platforms using a miniaturised protein G bioaffinity separative approach. IgG are separated from serum matrix components upon quantification with low non-specific binding in less than 5 min.

  5. Teduglutide Injection

    Science.gov (United States)

    ... who need additional nutrition or fluids from intravenous (IV) therapy. Teduglutide injection is in a class of medications ... of the ingredients.tell your doctor and pharmacist what other prescription and nonprescription medications, vitamins, nutritional supplements, and herbal products you are taking ...

  6. Dexrazoxane Injection

    Science.gov (United States)

    ... are used to treat or prevent certain side effects that may be caused by chemotherapy medications. Dexrazoxane injection (Zinecard) is used to prevent or decrease heart damage caused by doxorubicin in women who are taking the medication to treat breast cancer that has spread to other parts of the ...

  7. Triptorelin Injection

    Science.gov (United States)

    ... puberty too soon, resulting in faster than normal bone growth and development of sexual characteristics) in children 2 years and older. Triptorelin injection is in a class of medications called gonadotropin-releasing hormone (GnRH) agonists. It works by decreasing the amount ...

  8. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Results: Safe injection procedures regarding final waste disposal were sufficiently adopted, while measures regarding disposable injection equipment, waste containers, hand hygiene, as well as injection practices were inadequately carried out. Lack of job aid posters that promote safe injection and safe disposal of ...

  9. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... sures regarding disposable injection equipment, waste containers, hand hygiene ... injection practices lead to high prevalence of NSSIs in operating rooms. .... guidelines, the availability of training courses to HCWs, and provi-.

  10. Injection Laryngoplasty Materials

    OpenAIRE

    Haldun Oðuz

    2013-01-01

    Injection laryngoplasty is one of the treatment options for voice problems. In the recent years, more safe and more biocompatible injection materials are available on the market. Long and short term injection materials are discussed in this review.

  11. Penicillin G Procaine Injection

    Science.gov (United States)

    Penicillin G procaine injection is used to treat certain infections caused by bacteria. Penicillin G procaine injection should not be used to ... early in the treatment of certain serious infections. Penicillin G procaine injection is in a class of ...

  12. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... Background: Of the estimated 384,000 needle-stick injuries occurring in hospitals each year, 23% occur in surgical settings. This study was conducted to assess safe injection procedures, injection practices, and circumstances contributing to needlestick and sharps injures (NSSIs) in operating rooms.

  13. Sodium Ferric Gluconate Injection

    Science.gov (United States)

    Sodium ferric gluconate injection is used to treat iron-deficiency anemia (a lower than normal number of ... are also receiving the medication epoetin (Epogen, Procrit). Sodium ferric gluconate injection is in a class of ...

  14. Calcitonin Salmon Injection

    Science.gov (United States)

    Calcitonin salmon injection is used to treat osteoporosis in postmenopausal women. Osteoporosis is a disease that causes bones to weaken and break more easily. Calcitonin salmon injection is also used to treat Paget's disease ...

  15. Iron Dextran Injection

    Science.gov (United States)

    Iron dextran injection is used to treat iron-deficiency anemia (a lower than normal number of red blood cells ... treated with iron supplements taken by mouth. Iron dextran injection is in a class of medications called ...

  16. Aminocaproic Acid Injection

    Science.gov (United States)

    Aminocaproic acid injection is used to control bleeding that occurs when blood clots are broken down too quickly. This ... the baby is ready to be born). Aminocaproic acid injection is also used to control bleeding in ...

  17. Deoxycholic Acid Injection

    Science.gov (United States)

    Deoxycholic acid injection is used to improve the appearance and profile of moderate to severe submental fat ('double chin'; fatty tissue located under the chin). Deoxycholic acid injection is in a class of medications called ...

  18. Cluster beam injection

    International Nuclear Information System (INIS)

    Bottiglioni, F.; Coutant, J.; Fois, M.

    1978-01-01

    Areas of possible applications of cluster injection are discussed. The deposition inside the plasma of molecules, issued from the dissociation of the injected clusters, has been computed. Some empirical scaling laws for the penetration are given

  19. Antigen injection (image)

    Science.gov (United States)

    Leprosy is caused by the organism Mycobacterium leprae . The leprosy test involves injection of an antigen just under ... if your body has a current or recent leprosy infection. The injection site is labeled and examined ...

  20. SQL injection detection system

    OpenAIRE

    Vargonas, Vytautas

    2017-01-01

    SQL injection detection system Programmers do not always ensure security of developed systems. That is why it is important to look for solutions outside being reliant on developers. In this work SQL injection detection system is proposed. The system analyzes HTTP request parameters and detects intrusions. It is based on unsupervised machine learning. Trained by regular request data system detects outlier user parameters. Since training is not reliant on previous knowledge of SQL injections, t...

  1. Piezoelectric Injection Systems

    Science.gov (United States)

    Mock, R.; Lubitz, K.

    The origin of direct injection can be doubtlessly attributed to Rudolf Diesel who used air assisted injection for fuel atomisation in his first self-ignition engine. Although it became apparent already at that time that direct injection leads to reduced specific fuel consumption compared to other methods of fuel injection, it was not used in passenger cars for the moment because of its disadvantageous noise generation as the requirements with regard to comfort were seen as more important than a reduced specific consumption.

  2. Urinary incontinence - injectable implant

    Science.gov (United States)

    ... repair; ISD repair; Injectable bulking agents for stress urinary incontinence ... and disorders: physiology of micturition, voiding dysfunction, urinary incontinence, urinary tract infections, and painful bladder syndrome. In: Lobo ...

  3. Electron injection in microtron

    International Nuclear Information System (INIS)

    Axinescu, S.

    1977-01-01

    A review of the methods of injecting electrons in the microtron is presented. A special attention is paid to efficient injection systems developed by Wernholm and Kapitza. A comparison of advantages and disadvantages of both systems is made in relation to the purpose of the microtron. (author)

  4. Glenohumeral Joint Injections

    Science.gov (United States)

    Gross, Christopher; Dhawan, Aman; Harwood, Daniel; Gochanour, Eric; Romeo, Anthony

    2013-01-01

    Context: Intra-articular injections into the glenohumeral joint are commonly performed by musculoskeletal providers, including orthopaedic surgeons, family medicine physicians, rheumatologists, and physician assistants. Despite their frequent use, there is little guidance for injectable treatments to the glenohumeral joint for conditions such as osteoarthritis, adhesive capsulitis, and rheumatoid arthritis. Evidence Acquisition: We performed a comprehensive review of the available literature on glenohumeral injections to help clarify the current evidence-based practice and identify deficits in our understanding. We searched MEDLINE (1948 to December 2011 [week 1]) and EMBASE (1980 to 2011 [week 49]) using various permutations of intra-articular injections AND (corticosteroid OR hyaluronic acid) and (adhesive capsulitis OR arthritis). Results: We identified 1 and 7 studies that investigated intra-articular corticosteroid injections for the treatment of osteoarthritis and adhesive capsulitis, respectively. Two and 3 studies investigated the use of hyaluronic acid in osteoarthritis and adhesive capsulitis, respectively. One study compared corticosteroids and hyaluronic acid injections in the treatment of osteoarthritis, and another discussed adhesive capsulitis. Conclusion: Based on existing studies and their level of evidence, there is only expert opinion to guide corticosteroid injection for osteoarthritis as well as hyaluronic acid injection for osteoarthritis and adhesive capsulitis. PMID:24427384

  5. Dimethyl Ether Injection Studies

    DEFF Research Database (Denmark)

    Sorenson, Spencer C.; Glensvig, Michael; Abata, Duane L.

    1998-01-01

    A series of preliminary investigations has been performed in order to investigate the behavior of DME in a diesel injection environment. These studies have in-cluded visual observations of the spray penetration and angles for high pressure injection into Nitrogen using conventional jerk pump inje...

  6. THE RHIC INJECTION SYSTEM.

    Energy Technology Data Exchange (ETDEWEB)

    FISCHER,W.; GLENN,J.W.; MACKAY,W.W.; PTITSIN,V.; ROBINSON,T.G.; TSOUPAS,N.

    1999-03-29

    The RHIC injection system has to transport beam from the AGS-to-RHIC transfer line onto the closed orbits of the RHIC Blue and Yellow rings. This task can be divided into three problems. First, the beam has to be injected into either ring. Second, once injected the beam needs to be transported around the ring for one turn. Third, the orbit must be closed and coherent beam oscillations around the closed orbit should be minimized. We describe our solutions for these problems and report on system tests conducted during the RHIC Sextant test performed in 1997. The system will be fully commissioned in 1999.

  7. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    2014-01-01

    We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used in an inject......We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used...

  8. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used in an inject......We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used...

  9. Hip joint injection

    Science.gov (United States)

    ... medicine into the joint. The provider uses a real-time x-ray (fluoroscopy) to see where to place ... Wakefield RJ. Arthrocentesis and injection of joints and soft tissue. In: Firestein GS, Budd RC, Gabriel SE, ...

  10. Premixed direct injection disk

    Science.gov (United States)

    York, William David; Ziminsky, Willy Steve; Johnson, Thomas Edward; Lacy, Benjamin; Zuo, Baifang; Uhm, Jong Ho

    2013-04-23

    A fuel/air mixing disk for use in a fuel/air mixing combustor assembly is provided. The disk includes a first face, a second face, and at least one fuel plenum disposed therebetween. A plurality of fuel/air mixing tubes extend through the pre-mixing disk, each mixing tube including an outer tube wall extending axially along a tube axis and in fluid communication with the at least one fuel plenum. At least a portion of the plurality of fuel/air mixing tubes further includes at least one fuel injection hole have a fuel injection hole diameter extending through said outer tube wall, the fuel injection hole having an injection angle relative to the tube axis. The invention provides good fuel air mixing with low combustion generated NOx and low flow pressure loss translating to a high gas turbine efficiency, that is durable, and resistant to flame holding and flash back.

  11. Imipenem and Cilastatin Injection

    Science.gov (United States)

    Imipenem and cilastatin injection is used to treat certain serious infections that are caused by bacteria, including ... area), gynecological, blood, skin, bone, and joint infections. Imipenem is in a class of medications called carbapenem ...

  12. Quinupristin and Dalfopristin Injection

    Science.gov (United States)

    ... are in a class of medications called streptogramin antibiotics. They work by killing bacteria that cause infections.Antibiotics such as quinupristin and dalfopristin injection will not work for colds, flu, or other viral infections. Taking ...

  13. Botulinum toxin injection - larynx

    Science.gov (United States)

    Injection laryngoplasty; Botox - larynx: spasmodic dysphonia-BTX; Essential voice tremor (EVT)-btx; Glottic insufficiency; Percutaneous electromyography - guided botulinum toxin treatment; Percutaneous indirect laryngoscopy - guided botulinum toxin treatment; ...

  14. The PEP injection system

    International Nuclear Information System (INIS)

    Brown, K.L.; Avery, R.T.; Peterson, J.M.

    1988-01-01

    A system to transport 10-to-15-GeV electron and positron beams from the Stanford Linear Accelerator and to inject them into the PEP storage ring under a wide variety of lattice configurations has been designed. Optically, the transport line consists of three 360/degree/ phase-shift sections of FODO lattice, with bending magnets interspersed in such a way as to provide achromaticity, convenience in energy and emittance definition, and independent tuning of the various optical parameters for matching into the ring. The last 360/degree/ of phase shift has 88 milliradians of bend in a vertical plane and deposits the beam at the injection septum via a Lambertson magnet. Injection is accomplished by launching the beam with several centimeters of radial betatron amplitude in a fast bump provided by a triad of pulsed kicker magnets. Radiation damping reduces the collective amplitude quickly enough to allow injection at a high repetition rate

  15. Injection and Dump Systems

    CERN Document Server

    Bracco, C; Barnes, M J; Carlier, E; Drosdal, L N; Goddard, B; Kain, V; Meddahi, M; Mertens, V; Uythoven, J

    2012-01-01

    Performance and failures of the LHC injection and ex- traction systems are presented. In particular, a comparison with the 2010 run, lessons learnt during operation with high intensity beams and foreseen upgrades are described. UFOs, vacuum and impedance problems related to the injection and extraction equipment are analysed together with possible improvements and solutions. New implemented features, diagnostics, critical issues of XPOC and IQC applications are addressed.

  16. Syringe injectable electronics

    Science.gov (United States)

    Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M.

    2015-01-01

    Seamless and minimally-invasive three-dimensional (3D) interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating syringe injection and subsequent unfolding of submicrometer-thick, centimeter-scale macroporous mesh electronics through needles with a diameter as small as 100 micrometers. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with > 90% device yield. We demonstrate several applications of syringe injectable electronics as a general approach for interpenetrating flexible electronics with 3D structures, including (i) monitoring of internal mechanical strains in polymer cavities, (ii) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (iii) in vivo multiplexed neural recording. Moreover, syringe injection enables delivery of flexible electronics through a rigid shell, delivery of large volume flexible electronics that can fill internal cavities and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics. PMID:26053995

  17. Syringe-injectable electronics.

    Science.gov (United States)

    Liu, Jia; Fu, Tian-Ming; Cheng, Zengguang; Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M

    2015-07-01

    Seamless and minimally invasive three-dimensional interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating the syringe injection (and subsequent unfolding) of sub-micrometre-thick, centimetre-scale macroporous mesh electronics through needles with a diameter as small as 100 μm. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with >90% device yield. We demonstrate several applications of syringe-injectable electronics as a general approach for interpenetrating flexible electronics with three-dimensional structures, including (1) monitoring internal mechanical strains in polymer cavities, (2) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (3) in vivo multiplexed neural recording. Moreover, syringe injection enables the delivery of flexible electronics through a rigid shell, the delivery of large-volume flexible electronics that can fill internal cavities, and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics.

  18. Reactor water injection facility

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kazuhiro; Kinoshita, Shoichiro

    1997-05-02

    A steam turbine and an electric generator are connected by way of a speed convertor. The speed convertor is controlled so that the number of rotation of the electric generator is constant irrespective of the speed change of the steam turbine. A shaft coupler is disposed between the turbine and the electric generator or between the turbine and a water injection pump. With such a constitution, the steam turbine and the electric generator are connected by way of the speed convertor, and since the number of revolution of the electric generator is controlled to be constant, the change of the number of rotation of the turbine can be controlled irrespective of the change of the number of rotation of the electric generator. Accordingly, the flow rate of the injection water from the water injection pump to a reactor pressure vessel can be controlled freely thereby enabling to supply stable electric power. (T.M.)

  19. Oxygen injection facility

    International Nuclear Information System (INIS)

    Ota, Masamoto; Hirose, Yuki

    1998-01-01

    A compressor introduces air as a starting material and sends it to a dust removing device, a dehumidifying device and an adsorption/separation system disposed downstream. The facility of the present invention is disposed in the vicinity of an injection point and installed in a turbine building of a BWR type reactor having a pipeline of a feedwater system to be injected. The adsorbing/separation system comprises an adsorbing vessel and an automatic valve, and the adsorbing vessel is filled with an adsorbent for selectively adsorbing nitrogen. Zeolite is used as the adsorbent. Nitrogen in the air passing through the adsorbing vessel is adsorbed and removed under a pressurized condition, and a highly concentrated oxygen gas is formed. The direction of the steam of the adsorbed nitrogen is changed by an opening/closing switching operation of an automatic valve and released to the atmosphere (the pressure is released). Generated oxygen gas is stored under pressure in a tank, and injected to the pipeline of the feedwater system by an oxygen injection conduit by way of a flow rate control valve. In the adsorbing vessel, steps of adsorption, separation and storage under pressure are repeated successively. (I.N.)

  20. Water injection dredging

    NARCIS (Netherlands)

    Verhagen, H.J.

    2000-01-01

    Some twenty years ago WIS-dredging has been developed in the Netherlands. By injecting water into the mud layer, the water content of the mud becomes higher, it becomes fluid mud and will start to flow. The advantages of this system are that there is no need of transporting the mud in a hopper, and

  1. Botulinum Neurotoxin Injections

    Science.gov (United States)

    ... botulinum neurotoxin as much art as it is science. It is in your best interest to locate the most well-trained and experienced doctor you can find. Before making an appointment to receive botulinum neuro toxin injections, ask the office personnel which doctor ...

  2. Piperacillin and Tazobactam Injection

    Science.gov (United States)

    ... is in a class of medications called penicillin antibiotics. It works by killing bacteria that cause infection. Tazobactam is ... It works by preventing bacteria from destroying piperacillin.Antibiotics ... injection will not work for colds, flu, or other viral infections. Taking ...

  3. Meropenem and Vaborbactam Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria. Vaborbactam is in a class ... It works by preventing bacteria from destroying meropenem.Antibiotics such as meropenem and vaborbactam injection will not work for colds, flu, or other viral infections. Taking ...

  4. Cold water injection nozzles

    International Nuclear Information System (INIS)

    Kura, Masaaki; Maeda, Masamitsu; Endo, Takio.

    1979-01-01

    Purpose: To inject cold water in a reactor without applying heat cycles to a reactor container and to the inner wall of a feedwater nozzle by securing a perforated plate at the outlet of the cold water injection nozzle. Constitution: A disc-like cap is secured to the final end of a return nozzle of a control rod drive. The cap prevents the flow of a high temperature water flowing downward in the reactor from entering into the nozzle. The cap is perforated with a plurality of bore holes for injecting cold water into the reactor. The cap is made to about 100 mm in thickness so that the cold water passing through the bore holes is heated by the heat conduction in the cap. Accordingly, the flow of high temperature water flowing downwardly in the reactor is inhibited by the cap from backward flowing into the nozzle. Moreover, the flow of the cold water in the nozzle is controlled and rectified when passed through the bore holes in the cap and then injected into the reactor. (Yoshino, Y.)

  5. Pellet injection in WVIIA

    International Nuclear Information System (INIS)

    Renner, H.; Wuersohing, E.; Weller, A.; Jaeckel, H.; Hartfuss, H.; Hacker, H.; Ringler, H.; Buechl, K.

    1986-01-01

    The results of pellet injection experiments in the Wendelstein VII A stellarator are presented. The injector was a single shot pneumatic gun using deuterium pellets. Experiments were carried out in both ECRH and NI plasmas. Data is shown for plasma density, energy confinement, penetration depth and pellet ablation. Results are compared to a neutral gas shielding model

  6. Magnetron injection gun scaling

    International Nuclear Information System (INIS)

    Lawson, W.

    1988-01-01

    Existing analytic design equations for magnetron injection guns (MIG's) are approximated to obtain a set of scaling laws. The constraints are chosen to examine the maximum peak power capabilities of MIG's. The scaling laws are compared with exact solutions of the design equations and are supported by MIG simulations

  7. RHIC injection kicker impedance

    International Nuclear Information System (INIS)

    Mane, V.; Peggs, S.; Trbojevic, D.; Zhang, W.

    1995-01-01

    The longitudinal impedance of the RHIC injection kicker is measured using the wire method up to a frequency of 3 GHz. The mismatch between the 50 ohm cable and the wire and pipe system is calibrated using the TRL calibration algorithm. Various methods of reducing the impedance, such as coated ceramic pipe and copper strips are investigated

  8. SPS injection kicker magnet

    CERN Document Server

    1975-01-01

    One of the first-generation SPS injection kicker magnets. Lifting the tank-lid reveals the inner structure. For a more detailed description see 7502072X. See also 7502074X and Annual Report 1975, p.162. To the left: Roland Tröhler; to the right: Giacomo Busetta.

  9. Radiotracer injections through microfilters

    International Nuclear Information System (INIS)

    Huber, H.; Maschek, G.; Pichler, R.; Giesen, I.; Hatzl-Griesenhofer, M.; Maschek, W.

    2002-01-01

    Full text: Problems with the injection of radiotracers ( 99m Tc-HAMS, 99m Tc-DPD) to infants when administered through polar-filter-protected venous pathways caused us to get a closer look of what happens to a tracer in such a system. We simulated injections of the tracers mainly used at our institution in an in-vitro array and measured full and empty tracer syringes, filters (0.2 μm micropores) and the post-filter receptacle of the radioactivity. We calculated the percentage of filter-trapped activity and of activity in the receptacle. For several tracers we repeated this process with a neutral filter of the same pore size to get a comparison between the behavior in polarized and electrically inert filters. In general injection of a soluble radiotracer through a polar filter system means a dose loss in the filter of about 10 %, up to the tracer molecule size of IgG-antibodies. Suspended tracers, which consist of comparatively large particles, like RES- or pulmonary perfusion markers, are blocked by the filter, as can be foreseen with a particle size of >> 0.2 μm. DMSA and DPD (a biphosphonate), although both being soluble and rather small molecules, were blocked by the polar filter to a high extent, and by the neutral filter to a much lower, almost neglectable degree. The conclusions are: if possible avoid any use of a filter in your tracer injection pathway. Never use a filter with bone scan or DMSA applications. When doing uptake calculations you have to add the filter counts to the empty syringe value in the formula. If you cannot avoid to inject the radiotracer through a filter you have to replace the filter afterwards and treat the used filter as radioactive waste. The polarity of the filter material might severely affect retention of radiotracer in the filter. (author)

  10. Injection-controlled laser resonator

    Science.gov (United States)

    Chang, J.J.

    1995-07-18

    A new injection-controlled laser resonator incorporates self-filtering and self-imaging characteristics with an efficient injection scheme. A low-divergence laser signal is injected into the resonator, which enables the injection signal to be converted to the desired resonator modes before the main laser pulse starts. This injection technique and resonator design enable the laser cavity to improve the quality of the injection signal through self-filtering before the main laser pulse starts. The self-imaging property of the present resonator reduces the cavity induced diffraction effects and, in turn, improves the laser beam quality. 5 figs.

  11. Ceramic injection molding

    International Nuclear Information System (INIS)

    Agueda, Horacio; Russo, Diego

    1988-01-01

    Interest in making complex net-shape ceramic parts with good surface finishing and sharp tolerances without machining is a driving force for studying the injection molding technique. This method consists of softhening the ceramic material by means of adding some plastic and heating in order to inject the mixture under pressure into a relatively cold mold where solidification takes place. Essentially, it is the same process used in thermoplastic industry but, in the present case, the ceramic powder load ranges between 80 to 90 wt.%. This work shows results obtained from the fabrication of pieces of different ceramic materials (alumina, barium titanate ferrites, etc.) in a small scale, using equipments developed and constructed in the laboratory. (Author) [es

  12. Gaseous poison injection device

    International Nuclear Information System (INIS)

    Kubota, Ryuji; Sugisaki, Toshihiko; Inada, Ikuo.

    1983-01-01

    Purpose: To rapidly control the chain reaction due to thermal neutrons in a reactor core by using gaseous poisons as back-up means for control rod drives. Constitution: Gaseous poisons having a large neutron absorption cross section are used as back-up means for control rod drives. Upon failure of control rod insertion, the gaseous poisons are injected into the lower portion of the reactor core to control the reactor power. As the gaseous poisons, vapors at a high temperature and a higher pressure than that of the coolants in the reactor core are injected to control the reactor power due to the void effects. Since the gaseous poisons thus employed rapidly reach the reactor core and form gas bubbles therein, the deccelerating effect of the thermal neutrons is decreased to reduce the chain reaction. (Moriyama, K.)

  13. SPEAR 3 INJECTION KICKER

    International Nuclear Information System (INIS)

    2002-01-01

    The design of the SPEAR 3 injection kicker system is presented. This system will include three kicker magnets and their associated pulsers. The magnet design is based on the DELTA kicker magnets, which present a low RF impedance to the beam, and are relatively straight-forward to construct. The pulsers use cascaded IGBT stages that are based on the modulator pulsers developed by a SLAC/LLNL collaboration for the NLC. Design considerations and the results of prototype tests will be discussed

  14. Gallium arsenide injection lasers

    International Nuclear Information System (INIS)

    Thompson, G.H.B.

    1975-01-01

    The semiconductor injection laser includes a thin inner GaAs p-n junction layer between two outer GaAlAs layers which are backed by further thin outer GaAlAs layers with a heavier doping of AlAs. This reduces optical losses. Optical energy is further confined within the inner layers and the lasing threshold reduced by added outer GaAs layers of low electrical and thermal resistivity

  15. Hydrogen pellet injection device

    International Nuclear Information System (INIS)

    Kanno, Masahiro.

    1992-01-01

    In a hydrogen pellet injection device, a nozzle block having a hydrogen gas supply channel is disposed at the inner side of a main cryogenic housing, and an electric resistor is attached to the block. Further, a nozzle block and a hydrogen gas introduction pipe are attached by way of a thermal insulating spacer. Electric current is supplied to the resistor to positively heat the nozzle block and melt remaining solid hydrogen in the hydrogen gas supply channel. Further, the effect of temperature elevation due to the resistor is prevented from reaching the side of the hydrogen gas introduction pipe by the thermal insulation spacer. That is, the temperature of the nozzle block is directly and positively elevated, to melt the solid hydrogen rapidly. Preparation operation from the injection of the hydrogen pellet to the next injection can be completed in a shorter period of time compared with a conventional case thereby enabling to make the test more efficient. Further, only the temperature of the nozzle block is elevated with no effect of temperature elevation due to the resistor to other components by the thermal insulation flange. (N.H.)

  16. Penicillin G (Potassium, Sodium) Injection

    Science.gov (United States)

    Penicillin G injection is used to treat and prevent certain infections caused by bacteria. Penicillin G injection is in a class of medications called penicillins. It works by killing bacteria that cause infections. ...

  17. Amphotericin B Lipid Complex Injection

    Science.gov (United States)

    Amphotericin B lipid complex injection is used to treat serious, possibly life-threatening fungal infections in people who did ... respond or are unable to tolerate conventional amphotericin B therapy. Amphotericin B lipid complex injection is in ...

  18. Acupuncture Injection Combined with Electrokinetic Injection for Polydimethylsiloxane Microfluidic Devices

    Directory of Open Access Journals (Sweden)

    Ji Won Ha

    2017-01-01

    Full Text Available We recently reported acupuncture sample injection that leads to reproducible injection of nL-scale sample segments into a polydimethylsiloxane (PDMS microchannel for microchip capillary electrophoresis. The advantages of the acupuncture injection in microchip capillary electrophoresis include capability of minimizing sample loss and voltage control hardware and capability of introducing sample plugs into any desired position of a microchannel. However, the challenge in the previous study was to achieve reproducible, pL-scale sample injections into PDMS microchannels. In the present study, we introduce an acupuncture injection technique combined with electrokinetic injection (AICEI technique to inject pL-scale sample segments for microchip capillary electrophoresis. We carried out the capillary zone electrophoresis (CZE separation of FITC and fluorescein, and the mixture of 10 μM FITC and 10 μM fluorescein was separated completely by using the AICEI method.

  19. Water injection profiling

    International Nuclear Information System (INIS)

    Arnold, D.M.

    1982-01-01

    A method of neutron-gamma logging is described, in which water, injected in a cased well borehole with peforations, is irradiated with neutrons of 10 MeV or greater, and subsequent gamma radiation is detected by a pair of detectors along the borehole. Counting rates of detectors are analyzed in terms of two gamma ray energy windows. Linear flow velocity of fluid moving downward within the casing is used in conjunction with count rate data to determine volume flow rates of water moving in other directions. Apparatus includes a sonde with a neutron source and appropriate gamma sensors

  20. MKI UFOs at Injection

    CERN Document Server

    Baer, T; Bartmann, W; Bracco, C; Carlier, E; Chanavat, C; Drosdal, L; Garrel, N; Goddard, B; Kain, V; Mertens, V; Uythoven, J; Wenninger, J; Zerlauth, M

    2011-01-01

    During the MD, the production mechanism of UFOs at the injection kicker magnets (MKIs) was studied. This was done by pulsing the MKIs on a gap in the circulating beam, which led to an increased number of UFOs. In total 43 UFO type beam loss patterns at the MKIs were observed during the MD. The MD showed that pulsing the MKIs directly induces UFO type beam loss patterns. From the temporal characteristics of the loss profile, estimations about the dynamics of the UFOs are made.

  1. SQL Injection Defenses

    CERN Document Server

    Nystrom, Martin

    2007-01-01

    This Short Cut introduces you to how SQL injection vulnerabilities work, what makes applications vulnerable, and how to protect them. It helps you find your vulnerabilities with analysis and testing tools and describes simple approaches for fixing them in the most popular web-programming languages. This Short Cut also helps you protect your live applications by describing how to monitor for and block attacks before your data is stolen. Hacking is an increasingly criminal enterprise, and web applications are an attractive path to identity theft. If the applications you build, manage, or guar

  2. Efficient Spin Injection into Semiconductor

    International Nuclear Information System (INIS)

    Nahid, M.A.I.

    2010-06-01

    Spintronic research has made tremendous progress nowadays for making future devices obtain extra advantages of low power, and faster and higher scalability compared to present electronic devices. A spintronic device is based on the transport of an electron's spin instead of charge. Efficient spin injection is one of the very important requirements for future spintronic devices. However, the effective spin injection is an exceedingly difficult task. In this paper, the importance of spin injection, basics of spin current and the essential requirements of spin injection are illustrated. The experimental technique of electrical spin injection into semiconductor is also discussed based on the experimental experience. The electrical spin injection can easily be implemented for spin injection into any semiconductor. (author)

  3. Premixed direct injection nozzle

    Science.gov (United States)

    Zuo, Baifang [Simpsonville, SC; Johnson, Thomas Edward [Greer, SC; Lacy, Benjamin Paul [Greer, SC; Ziminsky, Willy Steve [Simpsonville, SC

    2011-02-15

    An injection nozzle having a main body portion with an outer peripheral wall is disclosed. The nozzle includes a plurality of fuel/air mixing tubes disposed within the main body portion and a fuel flow passage fluidly connected to the plurality of fuel/air mixing tubes. Fuel and air are partially premixed inside the plurality of the tubes. A second body portion, having an outer peripheral wall extending between a first end and an opposite second end, is connected to the main body portion. The partially premixed fuel and air mixture from the first body portion gets further mixed inside the second body portion. The second body portion converges from the first end toward said second end. The second body portion also includes cooling passages that extend along all the walls around the second body to provide thermal damage resistance for occasional flame flash back into the second body.

  4. SQL Injection Attacks and Defense

    CERN Document Server

    Clarke, Justin

    2012-01-01

    SQL Injection Attacks and Defense, First Edition: Winner of the Best Book Bejtlich Read Award "SQL injection is probably the number one problem for any server-side application, and this book unequaled in its coverage." -Richard Bejtlich, Tao Security blog SQL injection represents one of the most dangerous and well-known, yet misunderstood, security vulnerabilities on the Internet, largely because there is no central repository of information available for penetration testers, IT security consultants and practitioners, and web/software developers to turn to for help. SQL Injection Att

  5. Injectable barriers for waste isolation

    International Nuclear Information System (INIS)

    Persoff, P.; Finsterle, S.; Moridis, G.J.; Apps, J.; Pruess, K.; Muller, S.J.

    1995-03-01

    In this paper the authors report laboratory work and numerical simulation done in support of development and demonstration of injectable barriers formed from either of two fluids: colloidal silica or polysiloxane. Two principal problems addressed here are control of gel time and control of plume emplacement in the vadose zone. Gel time must be controlled so that the viscosity of the barrier fluid remains low long enough to inject the barrier, but increases soon enough to gel the barrier in place. During injection, the viscosity must be low enough to avoid high injection pressures which could uplift or fracture the formation. To test the grout gel time in the soil, the injection pressure was monitored as grouts were injected into sandpacks. When grout is injected into the vadose zone, it slumps under the influence of gravity, and redistributes due to capillary forces as it gels. The authors have developed a new module for the reservoir simulator TOUGH2 to model grout injection into the vadose zone, taking into account the increase of liquid viscosity as a function of gel concentration and time. They have also developed a model to calculate soil properties after complete solidification of the grout. The numerical model has been used to design and analyze laboratory experiments and field pilot tests. The authors present the results of computer simulations of grout injection, redistribution, and solidification

  6. A comparison of molding procedures - Contact, injection and vacuum injection

    Science.gov (United States)

    Cathiard, G.

    1980-06-01

    The technical and economic aspects of the contact, injection and vacuum injection molding of reinforced plastic components are compared for the example of a tractor roof with a gel-coated surface. Consideration is given to the possibility of reinforcement, number of smooth faces, condition of the gel-coated surface, reliability, and labor and workplace requirements of the three processes, and advantages of molding between the mold and a countermold in smooth faces, reliability, labor requirements, working surface and industrial hygiene are pointed out. The times and labor requirements of each step in the molding cycles are examined, and material requirements and yields, investment costs, amortization and product cost prices of the processes are compared. It is concluded that, for the specific component examined, the processes of vacuum injection and injection molding appear very interesting, with injection molding processes resulting in lower cost prices than contact molding for any production volume.

  7. Cooling water injection system

    International Nuclear Information System (INIS)

    Inai, Nobuhiko.

    1989-01-01

    In a BWR type reactor, ECCS system is constituted as a so-called stand-by system which is not used during usual operation and there is a significant discontinuity in relation with the usual system. It is extremely important that ECCS operates upon occurrence of accidents just as specified. In view of the above in the present invention, the stand-by system is disposed along the same line with the usual system. That is, a driving water supply pump for supplying driving water to a jet pump is driven by a driving mechanism. The driving mechanism drives continuously the driving water supply pump in a case if an expected accident such as loss of the function of the water supply pump, as well as during normal operation. That is, all of the water supply pump, jet pump, driving water supply pump and driving mechanism therefor are caused to operate also during normal operation. The operation of them are not initiated upon accident. Thus, the cooling water injection system can perform at high reliability to remarkably improve the plant safety. (K.M.)

  8. H- charge exchange injection systems

    International Nuclear Information System (INIS)

    Ankenbrandt, C.; Curtis, C.; Hojvat, C.; Johnson, R.P.; Owen, C.; Schmidt, C.; Teng, L.; Webber, R.C.

    1980-01-01

    The techniques and components required for injection of protons into cyclic accelerators by means of H - charge exchange processes are reviewed, with emphasis on the experience at Fermilab. The advantages of the technique are described. The design and performance of the system of injection of H - ions into the Fermilab Booster are detailed. (Auth.)

  9. Injection and lessons for 2012

    International Nuclear Information System (INIS)

    Bracco, C.; Barnes, M.J.; Bartmann, W.; Cornelis, K.; Drosdal, L.N.; Goddard, B.; Kain, V.; Meddahi, M.; Mertens, V.; Uythoven, J.

    2012-01-01

    Injection of 144 bunches into the LHC became fully operational during the 2011 run and one nominal injection of 288 bunches was accomplished. Several mitigation solutions were put in place to minimise losses from the Transfer Line (TL) collimators and losses from kicking de-bunched beam during injection. Nevertheless, shot-by- shot and bunch-by-bunch trajectory variations, as well as long terms drifts, were observed and required a regular re-steering of the TL implying a non negligible amount of time spent for injection setup. Likely sources of instability have been identified (i.e. MKE and MSE ripples) and possible cures to optimise 2012 operation are presented. Well defined references for TL steering will be defined in a more rigorous way in order to allow a more straightforward and faster injection setup. Encountered and potential issues of the injection system, in particular the injection kickers MKI, are discussed also in view of injections with a higher number of bunches. (authors)

  10. Injection and lessons for 2012

    CERN Document Server

    Bracco, C; Bartmann, W; Cornelis, K; Drosdal, L N; Goddard, B; Kain, V; Meddahi, M; Mertens, V; Uythoven, J

    2012-01-01

    Injection of 144 bunches into the LHC became fully operational during the 2011 run and a nominal injection of 288 bunches was accomplished during MD time. Several mitigation solutions were put in place to minimise losses from the transfer line (TL) collimators and losses from kicking debunched beam during injection. Nevertheless, shot-by-shot and bunch-by-bunch trajectory variations, as well as long terms drifts, were observed and required a regular resteering of the TL implying a non negligible amount of time spent for injection setup. Likely sources of instability have been identified (i.e. MKE and MSE ripples) and possible cures to optimise 2012 operation are presented. Well defined references for TL steering will be defined in a more rigorous way in order to allow a more straightforward and faster injection setup. Encountered and potential issues of the injection system, in particular the injection kickers MKI, are discussed also in view of injections with a higher number of bunches.

  11. Towards spin injection into silicon

    Energy Technology Data Exchange (ETDEWEB)

    Dash, S.P.

    2007-08-15

    Si has been studied for the purpose of spin injection extensively in this thesis. Three different concepts for spin injection into Si have been addressed: (1) spin injection through a ferromagnet-Si Schottky contact, (2) spin injection using MgO tunnel barriers in between the ferromagnet and Si, and (3) spin injection from Mn-doped Si (DMS) as spin aligner. (1) FM-Si Schottky contact for spin injection: To be able to improve the interface qualities one needs to understand the atomic processes involved in the formation of silicide phases. In order to obtain more detailed insight into the formation of such phases the initial stages of growth of Co and Fe were studied in situ by HRBS with monolayer depth resolution.(2) MgO tunnel barrier for spin injection into Si: The fabrication and characterization of ultra-thin crystalline MgO tunnel barriers on Si (100) was presented. (3) Mn doped Si for spin injection: Si-based diluted magnetic semiconductor samples were prepared by doping Si with Mn by two different methods i) by Mn ion implantation and ii) by in-diffusion of Mn atoms (solid state growth). (orig.)

  12. CT guided diagnostic foot injections

    International Nuclear Information System (INIS)

    Saifuddin, A.; Abdus-Samee, M.; Mann, C.; Singh, D.; Angel, J.C.

    2005-01-01

    AIM: To describe a CT technique for guiding diagnostic and therapeutic injections in the hind- and mid-foot. MATERIALS AND METHODS: Over a period of 50 months, 28 individuals were referred for diagnostic and therapeutic hind- and mid-foot injections before possible arthrodesis. A CT technique was developed that allowed entry into the various joints using a vertical approach. Numbers of joints injected were as follows: posterior subtalar, 21; talonavicular, 4; calcaneonavicular, calcaneocuboid, navicular-cuneiform and 5th metatarsocuboid joints, 1 each. RESULTS: All injections but one were technically successful. Significant relief of symptoms was noted by 16 participants, whereas for 9 there was no improvement and for 3 a partial response was achieved. CONCLUSION: CT is a simple and safe alternative to fluoroscopy for guiding diagnostic and therapeutic foot injections, and may be the technique of choice in cases of disordered anatomy

  13. Compressed air injection technique to standardize block injection pressures.

    Science.gov (United States)

    Tsui, Ban C H; Li, Lisa X Y; Pillay, Jennifer J

    2006-11-01

    Presently, no standardized technique exists to monitor injection pressures during peripheral nerve blocks. Our objective was to determine if a compressed air injection technique, using an in vitro model based on Boyle's law and typical regional anesthesia equipment, could consistently maintain injection pressures below a 1293 mmHg level associated with clinically significant nerve injury. Injection pressures for 20 and 30 mL syringes with various needle sizes (18G, 20G, 21G, 22G, and 24G) were measured in a closed system. A set volume of air was aspirated into a saline-filled syringe and then compressed and maintained at various percentages while pressure was measured. The needle was inserted into the injection port of a pressure sensor, which had attached extension tubing with an injection plug clamped "off". Using linear regression with all data points, the pressure value and 99% confidence interval (CI) at 50% air compression was estimated. The linearity of Boyle's law was demonstrated with a high correlation, r = 0.99, and a slope of 0.984 (99% CI: 0.967-1.001). The net pressure generated at 50% compression was estimated as 744.8 mmHg, with the 99% CI between 729.6 and 760.0 mmHg. The various syringe/needle combinations had similar results. By creating and maintaining syringe air compression at 50% or less, injection pressures will be substantially below the 1293 mmHg threshold considered to be an associated risk factor for clinically significant nerve injury. This technique may allow simple, real-time and objective monitoring during local anesthetic injections while inherently reducing injection speed.

  14. Optimization of injection law for direct injection diesel engine

    International Nuclear Information System (INIS)

    Feola, M.; Bella, G.; Pelloni, P.; Casoli, P.; Toderi, G.; Cantore, G.

    1992-01-01

    This paper describes how different timing and shape of the injection law can influence pollutant emission of a direct injection diesel engine. The study was carried out making use of a multizone thermodynamic model as regards the closed valve phase, and a filling-emptying one as regards the open valve phase. After being calibrated by comparison with experimental data, the abovementioned model was used for injection law optimization as regards minimum pollutant concentration (NO x and soot) in the exhaust gases with the smallest engine performance reduction possible

  15. Injection, injectivity and injectability in geothermal operations: problems and possible solutions. Phase I. Definition of the problems

    Energy Technology Data Exchange (ETDEWEB)

    Vetter, O.J.; Crichlow, H.B.

    1979-02-14

    The following topics are covered: thermodynamic instability of brine, injectivity loss during regular production and injection operations, injectivity loss caused by measures other than regular operations, heat mining and associated reservoir problems in reinjection, pressure maintenance through imported make-up water, suggested solutions to injection problems, and suggested solutions to injection problems: remedial and stimulation measures. (MHR)

  16. Worldwide Injection Technique Questionnaire Study: Population Parameters and Injection Practices.

    Science.gov (United States)

    Frid, Anders H; Hirsch, Laurence J; Menchior, Astrid R; Morel, Didier R; Strauss, Kenneth W

    2016-09-01

    From February 1, 2014, through June 30, 2015, 13,289 insulin-injecting patients from 423 centers in 42 countries took part in one of the largest surveys ever performed in diabetes. The goal was to assess patient characteristics, as well as historical and practical aspects of their injection technique. Results show that 4- and 8-mm needle lengths are each used by nearly 30% of patients and 5- and 6-mm needles each by approximately 20%. Higher consumption of insulin (as measured by total daily dose) is associated with having lipohypertrophy (LH), injecting into LH, leakage from the injection site, and failing to reconstitute cloudy insulin. Glycated hemoglobin values are, on average, 0.5% higher in patients with LH and are significantly higher with incorrect rotation of sites and with needle reuse. Glycated hemoglobin values are lower in patients who distribute their injections over larger injection areas and whose sites are inspected routinely. The frequencies of unexpected hypoglycemia and glucose variability are significantly higher in those with LH, those injecting into LH, those who incorrectly rotate sites, and those who reuse needles. Needles associated with diabetes treatment are the most commonly used medical sharps in the world. However, correct disposal of sharps after use is critically suboptimal. Many used sharps end up in public trash and constitute a major accidental needlestick risk. Use of these data should stimulate renewed interest in and commitment to optimizing injection practices in patients with diabetes. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  17. Injection nozzle for a turbomachine

    Science.gov (United States)

    Uhm, Jong Ho; Johnson, Thomas Edward; Kim, Kwanwoo

    2012-09-11

    A turbomachine includes a compressor, a combustor operatively connected to the compressor, an end cover mounted to the combustor, and an injection nozzle assembly operatively connected to the combustor. The injection nozzle assembly includes a first end portion that extends to a second end portion, and a plurality of tube elements provided at the second end portion. Each of the plurality of tube elements defining a fluid passage includes a body having a first end section that extends to a second end section. The second end section projects beyond the second end portion of the injection nozzle assembly.

  18. Financial methods for waterflooding injectate design

    Science.gov (United States)

    Heneman, Helmuth J.; Brady, Patrick V.

    2017-08-08

    A method of selecting an injectate for recovering liquid hydrocarbons from a reservoir includes designing a plurality of injectates, calculating a net present value of each injectate, and selecting a candidate injectate based on the net present value. For example, the candidate injectate may be selected to maximize the net present value of a waterflooding operation.

  19. Interferon Gamma-1b Injection

    Science.gov (United States)

    Interferon gamma-1b injection is used to reduce the frequency and severity of serious infections in people with chronic ... severe, malignant osteopetrosis (an inherited bone disease). Interferon gamma-1b is in a class of medications called ...

  20. Injecting drug use: Gendered risk.

    Science.gov (United States)

    Zahnow, Renee; Winstock, Adam R; Maier, Larissa J; Levy, Jay; Ferris, Jason

    2018-06-01

    Research demonstrates gender related differences in drug-use practices and risk behaviours. Females' structural vulnerability stemming from traditional gender roles and gender-power relations may enhance their propensity to experience injecting related risk. In this paper we explore gender differences in injection practices at the initiation event, during the first year of injecting and in the most recent 12-month period, to inform more effective harm reduction strategies. Data used in this study were drawn from the Global Drug Survey 2015. The study employs chi-square and logistic regression to assess gender differences in injection behaviours in a sample of current injectors residing in six global regions: North-West Europe; Southern Eastern Europe; North America. South America and Oceania. Females were more likely than males to report being injected by an intimate partner at initiation (OR = 4.4, 95%CI: 2.2-8.8), during the first year of injecting (OR = 4.8, 95% CI: 2.4-9.3) and in the most recent 12-month period (OR = 2.5, 95%CI: 1.0-6.2). Females reported greater difficulties accessing sterile equipment (X 2 (2,N = 453) = 8.2, p = 0.02) and were more likely to share injecting equipment than males (X 2 (1,N = 463) = 3.9, p = 0.05). Our findings highlight females' continued dependence on their intimate partner to administer the injection into the first year of their injecting career. Females remained more likely than males to rely on intimate partners for injection during the most recent 12-month period. Females report greater difficulties in sourcing sterile equipment and are more likely to share injecting equipment. We suggest that these findings reflect the broader social structure in which females are disempowered through traditional gender roles and the lack of gender appropriate harm reduction services. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Vocal fold injection medialization laryngoplasty.

    Science.gov (United States)

    Modi, Vikash K

    2012-01-01

    Unilateral vocal fold paralysis (UVFP) can cause glottic insufficiency that can result in hoarseness, chronic cough, dysphagia, and/or aspiration. In rare circumstances, UVFP can cause airway obstruction necessitating a tracheostomy. The treatment options for UVFP include observation, speech therapy, vocal fold injection medialization laryngoplasty, thyroplasty, and laryngeal reinnervation. In this chapter, the author will discuss the technique of vocal fold injection for medialization of a UVFP. Copyright © 2012 S. Karger AG, Basel.

  2. Accidental epidural injection of Atropine

    Directory of Open Access Journals (Sweden)

    Udayan Bakshi

    2013-01-01

    Full Text Available Intrathecal injection of drugs for anesthesia, regional analgesia, and chronic pain management are common practice now. Local anesthetic, adjuvants, and opioids are in common use. Human error in the Operation Theater and the Intensive Care Unit setup is also known and reported, due to stress and overwork. A case of unintentional atropine injection intrathecally, which was closely observed for any untoward effects, is reported here.

  3. Injection and extraction for cyclotrons

    International Nuclear Information System (INIS)

    Heikkinen, P.

    1994-01-01

    External ion sources for cyclotrons are needed for polarised and heavy ions. This calls for injection systems, either radial or axial. Radial injection is also needed when a cyclotron works as a booster after another cyclotron or a linear accelerator (usually tandem). Requirements for injection differ from separated sector cyclotrons where there is plenty of room to house inflectors and/or strippers, to superconducting cyclotrons where the space is limited by a small magnet gap, and high magnetic field puts other limitations to the inflectors. Several extraction schemes are used in cyclotrons. Stripping injection is used for H - and also for heavy ions where the q/m ratio is usually doubled. For other cases, electric and magnetic deflection has to be used. To increase the turn separation before the first deflector, both resonant and non-resonant schemes are used. In this lecture, external injection systems are surveyed and some rules to thumb for injection parameters are given. Extraction schemes are also reviewed. (orig.)

  4. ITER Neutral Beam Injection System

    International Nuclear Information System (INIS)

    Ohara, Yoshihiro; Tanaka, Shigeru; Akiba, Masato

    1991-03-01

    A Japanese design proposal of the ITER Neutral Beam Injection System (NBS) which is consistent with the ITER common design requirements is described. The injection system is required to deliver a neutral deuterium beam of 75MW at 1.3MeV to the reactor plasma and utilized not only for plasma heating but also for current drive and current profile control. The injection system is composed of 9 modules, each of which is designed so as to inject a 1.3MeV, 10MW neutral beam. The most important point in the design is that the injection system is based on the utilization of a cesium-seeded volume negative ion source which can produce an intense negative ion beam with high current density at a low source operating pressure. The design value of the source is based on the experimental values achieved at JAERI. The utilization of the cesium-seeded volume source is essential to the design of an efficient and compact neutral beam injection system which satisfies the ITER common design requirements. The critical components to realize this design are the 1.3MeV, 17A electrostatic accelerator and the high voltage DC acceleration power supply, whose performances must be demonstrated prior to the construction of ITER NBI system. (author)

  5. New injection recommendations for patients with diabetes

    NARCIS (Netherlands)

    Frid, A.; Hirsch, L.; Gaspar, R.; Hicks, D.; Kreugel, G.; Liersch, J.; Letondeur, C.; Sauvanet, J. P.; Tubiana-Rufi, N.; Strauss, K.

    Aim: Injections administered by patients are one of the mainstays of diabetes management. Proper injection technique is vital to avoiding intramuscular injections, ensuring appropriate delivery to the subcutaneous tissues and avoiding common complications such as lipohypertrophy. Yet few formal

  6. Fluid injection and induced seismicity

    Science.gov (United States)

    Kendall, Michael; Verdon, James

    2016-04-01

    The link between fluid injection, or extraction, and induced seismicity has been observed in reservoirs for many decades. In fact spatial mapping of low magnitude events is routinely used to estimate a stimulated reservoir volume. However, the link between subsurface fluid injection and larger felt seismicity is less clear and has attracted recent interest with a dramatic increase in earthquakes associated with the disposal of oilfield waste fluids. In a few cases, hydraulic fracturing has also been linked to induced seismicity. Much can be learned from past case-studies of induced seismicity so that we can better understand the risks posed. Here we examine 12 case examples and consider in particular controls on maximum event size, lateral event distributions, and event depths. Our results suggest that injection volume is a better control on maximum magnitude than past, natural seismicity in a region. This might, however, simply reflect the lack of baseline monitoring and/or long-term seismic records in certain regions. To address this in the UK, the British Geological Survey is leading the deployment of monitoring arrays in prospective shale gas areas in Lancashire and Yorkshire. In most cases, seismicity is generally located in close vicinity to the injection site. However, in some cases, the nearest events are up to 5km from the injection point. This gives an indication of the minimum radius of influence of such fluid injection projects. The most distant events are never more than 20km from the injection point, perhaps implying a maximum radius of influence. Some events are located in the target reservoir, but most occur below the injection depth. In fact, most events lie in the crystalline basement underlying the sedimentary rocks. This suggests that induced seismicity may not pose a leakage risk for fluid migration back to the surface, as it does not impact caprock integrity. A useful application for microseismic data is to try and forecast induced seismicity

  7. Proton accumulator ring injection studies

    International Nuclear Information System (INIS)

    Cooper, R.K.; Neil, V.K.

    1977-01-01

    Protons may be created in an accelerator or storage ring by stripping electrons from neutral hydrogen atoms that have been injected into the machine. Because Liouville's theorem is violated by this type of injection, particles may be continually injected into a region of phase space that is already populated, and the density in that region increases with time. A computational investigation was made of the evolution of the distribution of particles in longitudinal phase space during such an injection process for a storage ring operating below the transition energy. In one calculation, an rf cavity is present in the ring and particles are injected into the stable phase region once each revolution. The purpose of this calculation is to determine the rf voltage necessary to overcome the longitudinal self-forces and contain the particles within the region of stable phase. In a second calculation, the rf is turned off, so that there is spreading in azimuth of the injected particles (i.e., de-bunching). The de-bunching occurs because of the initial energy spread and the action of the self-forces. One purpose of the calculation is to determine the total energy spread after a given number of revolutions. Another purpose is to elucidate the effect of finite resistance in the vacuum tank walls. For sufficiently high current, the finite resistance can cause bunching of a beam that is initially uniform in azimuth. Therefore it might be expected that the finite resistance would inhibit or prevent de-bunching once the number of particles injected reaches some threshold, and that this threshold would depend upon the energy spread in the beam

  8. Physics of the current injection process during localized helicity injection

    Science.gov (United States)

    Hinson, Edward Thomas

    An impedance model has been developed for the arc-plasma cathode electron current source used in localized helicity injection tokamak startup. According to this model, a potential double layer (DL) is established between the high-density arc plasma (narc ˜ 1021 m-3) in the electron source, and the less-dense external tokamak edge plasma (nedge ˜ 10 18 m-3) into which current is injected. The DL launches an electron beam at the applied voltage with cross-sectional area close to that of the source aperture: Ainj ≈ 2 cm 2. The injected current, Iinj, increases with applied voltage, Vinj, according to the standard DL scaling, Iinj ˜ V(3/2/ inj), until the more restrictive of two limits to beam density nb arises, producing Iinj ˜ V(1/2/inj), a scaling with beam drift velocity. For low external tokamak edge density nedge, space-charge neutralization of the intense electron beam restricts the injected beam density to nb ˜ nedge. At high Jinj and sufficient edge density, the injected current is limited by expansion of the DL sheath, which leads to nb ˜ narc. Measurements of narc, Iinj , nedge, Vinj, support these predicted scalings, and suggest narc as a viable control actuator for the source impedance. Magnetic probe signals ≈ 300 degrees toroidally from the injection location are consistent with expectations for a gyrating, coherent electron beam with a compact areal cross-section. Technological development of the source has allowed an extension of the favorable Iinj ˜ V(1/2/inj) to higher power without electrical breakdown.

  9. Rituals in nursing: intramuscular injections.

    Science.gov (United States)

    Greenway, Kathleen

    2014-12-01

    To consider to what extent intramuscular injection technique can be described to remain entrenched in ritualistic practice and how evidence-based practice should be considered and applied to the nursing practice of this essential skill. The notion of rituals within nursing and the value or futile impact they afford to this essential nursing skill will be critically reviewed. Discursive paper. Literature review from 2002-2013 to review the current position of intramuscular injection injections. Within the literature review, it became clear that there are several actions within the administration of an intramuscular injection that could be perceived as ritualistic and require consideration for contemporary nursing practice. The essential nursing skill of intramuscular injection often appears to fit into the description of a ritualised practice. By providing evidence-based care, nurses will find themselves empowered to make informed decisions based on clinical need and using their clinical judgement. For key learning, it will outline with rationale how site selection, needle selection, insertion technique and aspiration can be cited as examples of routinised or ritualistic practice and why these should be rejected in favour of an evidence-based approach. The effect on some student nurses of experiencing differing practices between what is taught at university and what is often seen in clinical practice will also be discussed. © 2014 John Wiley & Sons Ltd.

  10. TARA beamline and injection system

    International Nuclear Information System (INIS)

    Post, R.S.; Brindza, P.; Coleman, J.W.; Torti, R.P.; Blackfield, D.T.; Goodrich, P.

    1983-01-01

    The TARA beamline for neutral beam injection will permit one to three sources to fire into each plug (60 degree or optional 90 degree injection with respect to the TARA axis) or into each anchor (90 degree injection only). The sources, pre-aimed on their mounting plate at the NB test stand, may be fired into neutralizer ducts or optionally through a magnesium curtain, and the unneutralized fraction is dumped by the TARA fringing field onto a receiver plate. The beamline is housed in a cylindrical tank with the beam axis along the tank diameter at the midplane. The tank will be sorption pumped using LN + T/sub I/ or N/sub B/ and/or e-beam gettering. The beam burial tank contains sed arrays and a thin foil dump which reaches sufficiently high temperatures during the shot to boil out gas between shots

  11. Automated injection of slurry samples in flow-injection analysis

    NARCIS (Netherlands)

    Hulsman, M.H.F.M.; Hulsman, M.; Bos, M.; van der Linden, W.E.

    1996-01-01

    Two types of injectors are described for introducing solid samples as slurries in flow analysis systems. A time-based and a volume-based injector based on multitube solenoid pinch valves were built, both can be characterized as hydrodynamic injectors. Reproducibility of the injections of dispersed

  12. Effect of injection timing and injection pressure on the performance ...

    African Journals Online (AJOL)

    DR OKE

    This paper discusses the feasibility study on the utilization of biodiesel ester of Honge oil (EHO) in common rail direct injection. (CRDI) engine. Biodiesel of EHO has been obtained by transesterification process and characterization has been done. Existing single cylinder diesel engine fitted with conventional mechanical ...

  13. Foam injection method and system

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, W C; Parmley, J B; Shepard, J C

    1977-05-10

    A method is described for more efficiently practicing in situ combustion techniques by generating a gas-water mist or foam adjacent to the combustion formation within the injection well. The mist or foam is forced out of the well into the formation to transport heat away from the burned region of the formation toward the periphery of the combustion region to conserve fuel. Also taught are a method and system for fluid treating a formation while maintaining enhanced conformance of the fluid injection profile by generating a mist or foam down-hole adjacent to the formation and then forcing the mist or foam out into the formation. (19 claims)

  14. Injection heating scenarios for TNS

    International Nuclear Information System (INIS)

    Rome, J.A.; Peng, Y.K.M.; Holmes, J.A.

    1977-07-01

    Neutral beam injection heating is a prime contender for heating TNS. However, injection into a full bore high density plasma during start-up will not give adequate beam penetration even with deuteron energies up to 300 keV and Z/sub eff/ < 1.5. But low density start-up may be feasible with deuteron energies of approximately 150 keV if advantage is taken of the α-heating and flux surface shifts which occur when β is increased

  15. Beam Scraping for LHC Injection

    CERN Document Server

    Burkhardt, H; Fischer, C; Gras, J-J; Koschik, A; Kramer, Daniel; Pedersen, S; Redaelli, S

    2007-01-01

    Operation of the LHC will require injection of very high intensity beams from the SPS to the LHC. Fast scrapers have been installed and will be used in the SPS to detect and remove any existing halo before beams are extracted, to minimize the probability for quenching of superconducting magnets at injection in the LHC. We briefly review the functionality of the scraper system and report about measurements that have recently been performed in the SPS on halo scraping and re-population of tails.

  16. Mastering Ninject for dependency injection

    CERN Document Server

    Baharestani, Daniel

    2013-01-01

    Mastering Ninject for Dependency Injection teaches you the most powerful concepts of Ninject in a simple and easy-to-understand format using lots of practical examples, diagrams, and illustrations.Mastering Ninject for Dependency Injection is aimed at software developers and architects who wish to create maintainable, extensible, testable, and loosely coupled applications. Since Ninject targets the .NET platform, this book is not suitable for software developers of other platforms. Being familiar with design patterns such as singleton or factory would be beneficial, but no knowledge of depende

  17. Pellet injection and toroidal confinement

    International Nuclear Information System (INIS)

    1989-12-01

    The proceedings of a technical committee meeting on pellet injection and toroidal confinement, held in Gut Ising, Federal Republic of Germany, 24-26 October, 1988, are given in this report. Most of the major fusion experiments are using pellet injectors; these were reported at this meeting. Studies of confinement, which is favorably affected, impurity transport, radiative energy losses, and affects on the ion temperature gradient instability were given. Studies of pellet ablation and effects on plasma profiles were presented. Finally, several papers described present and proposed injection guns. Refs, figs and tabs

  18. Therapeutic hip injections: Is the injection volume important?

    International Nuclear Information System (INIS)

    Young, R.; Harding, J.; Kingsly, A.; Bradley, M.

    2012-01-01

    Aim: To assess whether an increased volume of local anaesthetic injection given with intra-articular steroids improves symptom relief in osteoarthritis of the hip. Materials and methods: One hundred and ten patients with hip osteoarthritis were randomized into two groups (A and B). All patients were given 40 mg triamcinolone and 2 ml bupivicaine, and patients from group B were also given 6 ml of sterile water for injection. Change in WOMAC (Western Ontario and McMaster University Osteoarthritis Index Version 3.1) scores from baseline to 3 months were calculated and assessed for clinical and statistical significance. The patients were assessed for pain at 2 weekly intervals using the Oxford pain chart. Results: Patients from group B showed some reduction in stiffness (7%) and improved function (3%) compared with group A, and there were more clinical responders in these two categories. However, there was no significant statistical or clinical difference in WOMAC scores between the two groups at 3 months. There was also no statistical difference in pain symptoms between the two groups during the study period, measured at 2 weekly intervals. One hundred and two patients reached the study endpoint; eight patients who had bilateral hip injections were subsequently included in the analysis, and these patients did not alter the findings significantly. Conclusions: Published total injection volumes used for treating osteoarthritis of the hip with intra-articular steroids vary from 3 to 12 ml. The present study has shown that there is no detriment to using a larger volume of injectate, and recommends that practitioners use total volumes between 3 and 9 ml.

  19. Therapeutic hip injections: Is the injection volume important?

    Energy Technology Data Exchange (ETDEWEB)

    Young, R., E-mail: russell.young@gwh.nhs.uk [Department of Radiology, Great Western Hospital, Swindon (United Kingdom); Harding, J. [Department of Radiology, University Hospital Coventry, Coventry (United Kingdom); Kingsly, A. [Department of Mathematics and Statistics, Bristol Institue of Technology, University of the West of England, Bristol (United Kingdom); Bradley, M. [Department of Radiology, Southmead Hospital, Bristol (United Kingdom)

    2012-01-15

    Aim: To assess whether an increased volume of local anaesthetic injection given with intra-articular steroids improves symptom relief in osteoarthritis of the hip. Materials and methods: One hundred and ten patients with hip osteoarthritis were randomized into two groups (A and B). All patients were given 40 mg triamcinolone and 2 ml bupivicaine, and patients from group B were also given 6 ml of sterile water for injection. Change in WOMAC (Western Ontario and McMaster University Osteoarthritis Index Version 3.1) scores from baseline to 3 months were calculated and assessed for clinical and statistical significance. The patients were assessed for pain at 2 weekly intervals using the Oxford pain chart. Results: Patients from group B showed some reduction in stiffness (7%) and improved function (3%) compared with group A, and there were more clinical responders in these two categories. However, there was no significant statistical or clinical difference in WOMAC scores between the two groups at 3 months. There was also no statistical difference in pain symptoms between the two groups during the study period, measured at 2 weekly intervals. One hundred and two patients reached the study endpoint; eight patients who had bilateral hip injections were subsequently included in the analysis, and these patients did not alter the findings significantly. Conclusions: Published total injection volumes used for treating osteoarthritis of the hip with intra-articular steroids vary from 3 to 12 ml. The present study has shown that there is no detriment to using a larger volume of injectate, and recommends that practitioners use total volumes between 3 and 9 ml.

  20. Multi-shot type pellet injection device

    International Nuclear Information System (INIS)

    Onozuka, Masaki; Uchikawa, Takashi; Kuribayashi, Shitomi.

    1988-01-01

    Purpose: To inject pellets at high speed without melting or sublimating not-injected pellets even at a long pellet injection interval. Constitution: In the conventional multi-shot pellet injection device, the pellet injection interval is set depending on the plasma retention time. However, as the pellet injection interval is increased, not-injected pellets are melted or sublimated due to the introduced heat of acceleration gases supplied from an acceleration gas introduction pipe to give an effect on the dimensional shape of the pellets. In view of the above, a plurality of pellet forming and injection portions each comprising a carrier, an injection pipe and a holder are disposed independently of each other and pellets are formed and injected independently to thereby prevent the thermal effects of the acceleration gases. (Kamimura, M.)

  1. Multi-shot type pellet injection device

    Energy Technology Data Exchange (ETDEWEB)

    Onozuka, Masaki; Uchikawa, Takashi; Kuribayashi, Shitomi.

    1988-07-27

    Purpose: To inject pellets at high speed without melting or sublimating not-injected pellets even at a long pellet injection interval. Constitution: In the conventional multi-shot pellet injection device, the pellet injection interval is set depending on the plasma retention time. However, as the pellet injection interval is increased, not-injected pellets are melted or sublimated due to the introduced heat of acceleration gases supplied from an acceleration gas introduction pipe to give an effect on the dimensional shape of the pellets. In view of the above, a plurality of pellet forming and injection portions each comprising a carrier, an injection pipe and a holder are disposed independently of each other and pellets are formed and injected independently to thereby prevent the thermal effects of the acceleration gases. (Kamimura, M.).

  2. Gas injected washer plasma gun

    International Nuclear Information System (INIS)

    Jain, K.K.; John, P.I.; Punithavelu, A.M.; Rao, P.P.

    1980-01-01

    A plasma gun similar in geometry to the washer plasma gun has been operated with gas injected externally. hydrogen, nitrogen and argon plasmas have been ionised and accelerated to velocities of the order of 10 7 mm s -1 and densities 10 11 mm -3 . Higher parameter range is possible with higher electrical input power. (author)

  3. ENDOSCOPIC MACROPLASTIQUETM INJECTION FOR THE ...

    African Journals Online (AJOL)

    mucosally 1 cm distal to the bladder neck at 3, 6 and 9 o' clock positions. In 26 cases the 12 o' clock position was chosen to ensure a good occlusion of the bladder neck. The mean volume of Macroplastique injected was 3 ml. Results At a mean ...

  4. Medical simulator with injection device

    NARCIS (Netherlands)

    2011-01-01

    medical simulator 611 comprises a vessel 609 representing a simulated blood vessel. The vessel comprises a simulated vessel wall capable of being punctured by an electrically conductive injection needle 503. The vessel wall comprises a first electrically conductive layer for closing an electric

  5. PLT neutral beam injection systems

    International Nuclear Information System (INIS)

    Menon, M.M.; Barber, G.C.; Blue, C.W.

    1979-01-01

    A brief description of the Princeton Large Torus (PLT) neutral beam injection system is given and its performance characteristics are outlined. A detailed operational procedure is included, as are some tips on troubleshooting. Proper operation of the source is shown to be a crucial factor in system performance

  6. Preface to the injection tables

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    Twelve groups of dogs received intravenous injections of various doses of 226 Ra, 239 Pu, 228 Ra, 228 Th, 90 Sr, 241 Am, 249 Cf, or 252 Cf at approximately 17 months of age. The animals were euthanized when death appeared imminent. Data are presented on the calculated radiation dose to the skeleton and pathological changes observed at autopsy

  7. Enhanced Injection Molding Simulation of Advanced Injection Molds

    Directory of Open Access Journals (Sweden)

    Béla Zink

    2017-02-01

    Full Text Available The most time-consuming phase of the injection molding cycle is cooling. Cooling efficiency can be enhanced with the application of conformal cooling systems or high thermal conductivity copper molds. The conformal cooling channels are placed along the geometry of the injection-molded product, and thus they can extract more heat and heat removal is more uniform than in the case of conventional cooling systems. In the case of copper mold inserts, cooling channels are made by drilling and heat removal is facilitated by the high thermal conductivity coefficient of copper, which is several times that of steel. Designing optimal cooling systems is a complex process; a proper design requires injection molding simulations, but the accuracy of calculations depends on how precise the input parameters and boundary conditions are. In this study, three cooling circuit designs and three mold materials (Ampcoloy 940, 1.2311 (P20 steel, and MS1 steel were used and compared using numerical methods. The effect of different mold designs and materials on cooling efficiency were examined using calculated and measured results. The simulation model was adjusted to the measurement results by considering the joint gap between the mold inserts.

  8. 78 FR 23246 - Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for...

    Science.gov (United States)

    2013-04-18

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9804-8] Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for Exemption--Class I Hazardous Waste Injection; BASF... exemption to the land disposal Restrictions, under the 1984 Hazardous and Solid Waste [[Page 23247...

  9. Electrical injection schemes for nanolasers

    DEFF Research Database (Denmark)

    Lupi, Alexandra; Chung, Il-Sug; Yvind, Kresten

    2013-01-01

    The performance of injection schemes among recently demonstrated electrically pumped photonic crystal nanolasers has been investigated numerically. The computation has been carried out at room temperature using a commercial semiconductor simulation software. For the simulations two electrical...... of 3 InGaAsP QWs on an InP substrate has been chosen for the modeling. In the simulations the main focus is on the electrical and optical properties of the nanolasers i.e. electrical resistance, threshold voltage, threshold current and wallplug efficiency. In the current flow evaluation the lowest...... threshold current has been achieved with the lateral electrical injection through the BH; while the lowest resistance has been obtained from the current post structure even though this model shows a higher current threshold because of the lack of carrier confinement. Final scope of the simulations...

  10. Injectable agents affecting subcutaneous fats.

    Science.gov (United States)

    Chen, David Lk; Cohen, Joel L; Green, Jeremy B

    2015-09-01

    Mesotherapy is an intradermal or subcutaneous injection of therapeutic agents to induce local effects, and was pioneered in Europe during the 1950s. For the past 2 decades, there has been significant interest in the use of mesotherapy for minimally invasive local fat contouring. Based on the theorized lipolytic effects of the agent phosphatidylcholine, initial attempts involved its injection into subcutaneous tissue. With further studies, however, it became apparent that the activity attributed to phosphatidylcholine mesotherapy was due to the adipolytic effects of deoxycholate, a detergent used to solubilize phosphatidylcholine. Since then, clinical trials have surfaced that demonstrate the efficacy of a proprietary formulation of deoxycholate for local fat contouring. Current trials on mesotherapy with salmeterol, a b-adrenergic agonist and lipolysis stimulator, are underway-with promising preliminary results as well. ©2015 Frontline Medical Communications.

  11. Inadvertent intrathecal injection of atracurium.

    Science.gov (United States)

    Zirak, Nahid; Soltani, Ghasem; Ghomian, Naiere; Hasanpour, Mohamad Reza; Mashayekhi, Zahra

    2011-04-01

    This report relates how tracurium was given by mistake, intrathecally, during spinal anesthesia, to a 38-year-old woman, who was a candidate for abdominal hysterectomy. When no analgesia was observed, the mistake in giving the injection was understood. She was evaluated postoperatively by train of four ratio, measuring her breathing rate, eye opening, and protruding of tongue at one, two, twenty-four, and forty-eight hours, and then at one and two weeks, with the final evaluation the following month. The patient had normal timings during the operation and postoperation periods, and no abnormal findings were observed through the first month. This finding was contrary to several studies, which described adverse reactions due to accidental intrathecal injection of neuromuscular blocking drugs.

  12. Inadvertent intrathecal injection of atracurium

    Directory of Open Access Journals (Sweden)

    Nahid Zirak

    2011-01-01

    Full Text Available This report relates how tracurium was given by mistake, intrathecally, during spinal anesthesia, to a 38-year-old woman, who was a candidate for abdominal hysterectomy. When no analgesia was observed, the mistake in giving the injection was understood. She was evaluated postoperatively by train of four ratio, measuring her breathing rate, eye opening, and protruding of tongue at one, two, twenty-four, and forty-eight hours, and then at one and two weeks, with the final evaluation the following month. The patient had normal timings during the operation and postoperation periods, and no abnormal findings were observed through the first month. This finding was contrary to several studies, which described adverse reactions due to accidental intrathecal injection of neuromuscular blocking drugs.

  13. Model for pneumatic pellet injection

    International Nuclear Information System (INIS)

    Hogan, J.T.; Milora, S.L.; Schuresko, D.D.

    1983-07-01

    A hydrodynamic code has been developed to model the performance of pneumatic pellet injection systems. The code describes one dimensional, unsteady compressible gas dynamics, including gas friction and heat transfer to the walls in a system with variable area. The mass, momentum, and energy equations are solved with an iterated Lax-Wendroff scheme with additional numerical viscosity. The code is described and comparisons with experimental data are presented

  14. Spin Injection in Indium Arsenide

    Directory of Open Access Journals (Sweden)

    Mark eJohnson

    2015-08-01

    Full Text Available In a two dimensional electron system (2DES, coherent spin precession of a ballistic spin polarized current, controlled by the Rashba spin orbit interaction, is a remarkable phenomenon that’s been observed only recently. Datta and Das predicted this precession would manifest as an oscillation in the source-drain conductance of the channel in a spin-injected field effect transistor (Spin FET. The indium arsenide single quantum well materials system has proven to be ideal for experimental confirmation. The 2DES carriers have high mobility, low sheet resistance, and high spin orbit interaction. Techniques for electrical injection and detection of spin polarized carriers were developed over the last two decades. Adapting the proposed Spin FET to the Johnson-Silsbee nonlocal geometry was a key to the first experimental demonstration of gate voltage controlled coherent spin precession. More recently, a new technique measured the oscillation as a function of channel length. This article gives an overview of the experimental phenomenology of the spin injection technique. We then review details of the application of the technique to InAs single quantum well (SQW devices. The effective magnetic field associated with Rashba spin-orbit coupling is described, and a heuristic model of coherent spin precession is presented. The two successful empirical demonstrations of the Datta Das conductance oscillation are then described and discussed.

  15. Radial lean direct injection burner

    Science.gov (United States)

    Khan, Abdul Rafey; Kraemer, Gilbert Otto; Stevenson, Christian Xavier

    2012-09-04

    A burner for use in a gas turbine engine includes a burner tube having an inlet end and an outlet end; a plurality of air passages extending axially in the burner tube configured to convey air flows from the inlet end to the outlet end; a plurality of fuel passages extending axially along the burner tube and spaced around the plurality of air passage configured to convey fuel from the inlet end to the outlet end; and a radial air swirler provided at the outlet end configured to direct the air flows radially toward the outlet end and impart swirl to the air flows. The radial air swirler includes a plurality of vanes to direct and swirl the air flows and an end plate. The end plate includes a plurality of fuel injection holes to inject the fuel radially into the swirling air flows. A method of mixing air and fuel in a burner of a gas turbine is also provided. The burner includes a burner tube including an inlet end, an outlet end, a plurality of axial air passages, and a plurality of axial fuel passages. The method includes introducing an air flow into the air passages at the inlet end; introducing a fuel into fuel passages; swirling the air flow at the outlet end; and radially injecting the fuel into the swirling air flow.

  16. Long acting injectable hormonal contraceptives.

    Science.gov (United States)

    Fraser, I S

    1982-03-01

    Injectable hormonal preparations can be highly effective and satisfactory contraceptives. The two main preparations available today are depot medroxy progesterone acetate (DMPA) and norethisterone oenanthate (NET-OEN), but several other approaches are currently under clinical trial. Injectable contraceptives have some unique advantages which give them justifiably wide appeal amongst many groups of women. However, they do have a number of disadvantages including invariable menstrual disturbance and a delay in the return of fertility. One formulation of DMPA, Depo-Provera, is probably the most extensively investigated single hormonal contraceptive ever made. These studies indicate that it is remarkably safe and does not face any more unresolved issues than the combined pill, intrauterine device or tubal sterilization. However, for a number of disparate emotional and political reasons it has attracted the attention of several consumer and feminist groups, who have waged a prolonged and quite unjustified campaign against it. It is to be hoped that future debate will be conducted on a more informed, rational and less emotional basis. Injectable contraceptives should have an important place in the family planning armamentarium of all countries, and current developments should lead to a decrease in concerns about presently available agents. This should further increase the widespread acceptability of this approach to contraception.

  17. Outcomes After Diagnostic Hip Injection.

    Science.gov (United States)

    Lynch, T Sean; Steinhaus, Michael E; Popkin, Charles A; Ahmad, Christopher S; Rosneck, James

    2016-08-01

    To provide a comprehensive review of outcomes associated with local anesthetic (LA) or LA and corticosteroid (CS) diagnostic hip injections, and how well response predicts subsequent operative success. A systematic review from database (PubMed, Medline, Scopus, Embase) inception to January 2015 for English-language articles reporting primary patient outcomes data was performed, excluding studies with >50% underlying osteoarthritis. Studies were assessed by 2 reviewers who collected pertinent data. Seven studies were included, reporting on a total 337 patients undergoing diagnostic hip injection. The mean age was 34.4 years, with 5 studies reporting 94 (35.2%) males and 173 (64.8%) females. One study examined the rate of pain relief with LA (92.5%); 2 CS studies reported relief on a scale from 0% to 100% (no to complete relief), ranging from 61% to 82.3%; and 3 studies used 10-point pain scales, with a CS study noting a pain score of 1.0, an LA study with a score of 3.03, and 1 study using either CS or LA scores of 3 to 5.6. Duration of pain relief was 9.8 (CS) and 2.35 days (LA). By pathology, greatest relief was achieved in acetabular chondral injury (93.3%) and least in cam impingement (81.6%), with clinical and imaging findings being unreliable predictors of relief. One study showed nonresponse to be a strong predictor of negative surgical outcome for femoroacetabular impingement. Diagnostic hip injections provide substantial pain relief for patients with various hip pathologies, with limited data to suggest greatest relief for those with chondral injury. Clinical and imaging findings are unreliable predictors of injection response, and nonresponse to injection is a strong negative predictor of surgical outcome. Future research should focus on elucidating differences by underlying pathology and predicting future operative success. Level IV, systematic review. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights

  18. Promoting Safe Injection Practices : The Challenge Ahead

    Directory of Open Access Journals (Sweden)

    V K Srivastava

    2006-06-01

    Full Text Available Injections are one of the most common health care procedures in the world. Global estimates range between 12 billion-16 billion injections each year’. Most of the injections (90 to 95% are given for therapeutic purposes and only 5 to 10% are given for immunization. It is estimated that worldwide every year a billion injections are given to women and children for immunization. Up to half of these injections are currently thought to be unsafe. Due to the sheer burden of injections and the coresponding magnitude of unsafe injections, the proportion of blood borne pathogen transmission is much larger than is due to unsafe blood transfusion. Unsafe injections are responsible for million cases of Hepatitis B and C and an estimated one-quarter of a million cases of HIV annually. Worldwide 8 to 16 million hepatitis B, 2.3 - 4.7 million hepatitis C and 80,000 - 1,60,000 HIV infections are estimated to occur yearly form reuse of syringes and needles without adequate sterilization2. In the less developed countries, the unsafe injection practices account for an estimated $ 535 million in health care costs and result in nearly 1.3 million deaths a year. In a developing country like India where unnecessary injections are common, the total bur­den of injections is estimated to be 3.7 billion injections per year3. Certain studies that have been carried out in India,along with anecdotal evidence point towards a large numbe- of unnecessary, inappropriate, unsafe injections and inadequate sharps waste management4 5. A high proportion of injections given in India for immunization are unsafe due to reuse of needles/ syringes. The popularity of curative injections remains high due to various factors influencing the behaviour of prescribers / injection givers as well as clients.

  19. 21 CFR 522.1182 - Iron injection.

    Science.gov (United States)

    2010-04-01

    ... follows: (i) For prevention of iron deficiency anemia, inject 100 mg (1 mL) by intramuscular injection at 2 to 4 days of age. (ii) For treatment of iron deficiency anemia, inject 100 mg (1 mL) by... repeated in 14 to 21 days. (ii) For the treatment of anemia due to iron deficiency, administer an...

  20. Helical axial injection concept for cyclotrons

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, E.D.

    1981-01-01

    A concept for an external beam injection system using a helical beam path centered on the cyclotron axis is described. This system could be used to couple two accelerator stages, with or without intermediate stripping, in cases where conventional axial injection or radial injection are not practical.

  1. Helical axial injection concept for cyclotrons

    International Nuclear Information System (INIS)

    Hudson, E.D.

    1981-01-01

    A concept for an external beam injection system using a helical beam path centered on the cyclotron axis is described. This system could be used to couple two accelerator stages, with or without intermediate stripping, in cases where conventional axial injection or radial injection are not practical

  2. Fatal injection: a survey of modern code injection attack countermeasures

    Directory of Open Access Journals (Sweden)

    Dimitris Mitropoulos

    2017-11-01

    Full Text Available With a code injection attack (CIA an attacker can introduce malicious code into a computer program or system that fails to properly encode data that comes from an untrusted source. A CIA can have different forms depending on the execution context of the application and the location of the programming flaw that leads to the attack. Currently, CIAs are considered one of the most damaging classes of application attacks since they can severely affect an organisation’s infrastructure and cause financial and reputational damage to it. In this paper we examine and categorize the countermeasures developed to detect the various attack forms. In particular, we identify two distinct categories. The first incorporates static program analysis tools used to eliminate flaws that can lead to such attacks during the development of the system. The second involves the use of dynamic detection safeguards that prevent code injection attacks while the system is in production mode. Our analysis is based on nonfunctional characteristics that are considered critical when creating security mechanisms. Such characteristics involve usability, overhead, implementation dependencies, false positives and false negatives. Our categorization and analysis can help both researchers and practitioners either to develop novel approaches, or use the appropriate mechanisms according to their needs.

  3. Injection dynamics of gelled propellants

    Science.gov (United States)

    Yoon, Changjin

    Gel propellants have been recognized as attractive candidates for future propulsion systems due to the reduced tendency to spill and the energy advantages over solid propellants. One of strong benefits emphasized in gel propellant applications is a throttling capability, but the accurate flow control is more complicated and difficult than with conventional Newtonian propellants because of the unique rheological behaviors of gels. This study is a computational effort directed to enhance understanding of the injector internal flow characteristics for gel propellants under rocket injection conditions. In simulations, the emphasized rheology is a shear-thinning which represents a viscosity decrease with increasing a shear rate. It is described by a generalized Newtonian fluid constitutive equation and Carreau-Yasuda model. Using this rheological model, two injection schemes are considered in the present study: axially-fed and cross-fed injection for single-element and multi-element impinging injectors, respectively. An axisymmetric model is developed to describe the axially-fed injector flows and fully three-dimensional model is utilized to simulate cross-fed injector flows. Under axially-fed injection conditions investigated, three distinct modes, an unsteady, steady, and hydraulic flip mode, are observed and mapped in terms of Reynolds number and orifice design. In an unsteady mode, quasi-periodic oscillations occur near the inlet lip leading mass pulsations and viscosity fluctuations at the orifice exit. This dynamic behavior is characterized using a time-averaged discharge coefficient, oscillation magnitude and frequency by a parametric study with respect to an orifice design, Reynolds number and rheology. As a result, orifice exit flows for gel propellants appear to be significantly influenced by a viscous damping and flow resistance due to a shear thinning behavior and these are observed in each factors considered. Under conditions driven by a manifold crossflow

  4. Injection characteristics of dimethyl ether

    Energy Technology Data Exchange (ETDEWEB)

    Glensvig, M.

    1996-09-01

    Dimethyl ether (DME) has proved to be a new ultra-clean alternative fuel for diesel engines. Engine tests have shown considerably lower NO{sub x} emissions, no particle emissions and lower noise compared to that obtained from normal diesel engine operation. DME also has demonstrated favorable response to Exhaust Gas Recirculation (EGR). The purpose of this investigation was to achieve a better understanding of the fundamental spray behavior of DME. Fundamental spray behaviour was characterized by fuel spray penetration and angle, atomization and droplet size and evaporation. The influence of fuel characteristics, nozzle geometry and ambient pressure on the DME and diesel spray behavior was investigated. Fuel was injected into an unheated injection chamber with a ambient pressure of 15 bar and 25 bar, respectively, giving a simplified simulation of the environment in an operating engine. Two nozzles were studied: a single hole nozzle and a pintle nozzle. A conventional fuel injection system was used for both nozzles. Injection parameters of RPM, throttle position, fuel line length and chamber environment were held constant for both nozzles. The sprays were visualized using schlieren and high speed photography. Results show that the general appearance of the DME spray is similar to that of diesel spray. The core of the DME spray seems less dense and the spray tip less sharp compared to diesel spray, indicating smaller droplets with a lower momentum in the core of the DME spray. Schlieren film shows that with both DME and diesel fuel, the spray tip only consists of liquid and that evaporation occurs after a brief time interval. Penetration of DME is about one third that of diesel using the pintle nozzle. Also, the spray angle is considerably larger for the DME spray compared to the diesel spray. A comparatively smaller difference in penetration is observed using the hole nozzle. Differences in penetration for the hole nozzle are within the limit of the penetration

  5. Electrical Injection Schemes for Nanolasers

    DEFF Research Database (Denmark)

    Lupi, Alexandra; Chung, Il-Sug; Yvind, Kresten

    2014-01-01

    Three electrical injection schemes based on recently demonstrated electrically pumped photonic crystal nanolasers have been numerically investigated: 1) a vertical p-i-n junction through a post structure; 2) a lateral p-i-n junction with a homostructure; and 3) a lateral p-i-n junction....... For this analysis, the properties of different schemes, i.e., electrical resistance, threshold voltage, threshold current, and internal efficiency as energy requirements for optical interconnects are compared and the physics behind the differences is discussed....

  6. Temperature stabilization of injection lasers

    International Nuclear Information System (INIS)

    Albanese, A.

    1987-01-01

    Apparatus which stabilizes the temperature, and thereby the output wavelength, of an injection laser. Means monitor the laser terminal voltage across a laser and derive a voltage therefrom which is proportional to the junction voltage of the laser. Means compares the voltage to a reference value from source and a temperature controller adjusts the laser temperature in response to the results of the comparison. Further embodiments of the present invention vary the output wavelength of the laser by varying the reference value from source against which the laser junction voltage is compared. (author)

  7. Compartmentalized safety coolant injection system

    International Nuclear Information System (INIS)

    Johnson, F.T.

    1983-01-01

    A safety coolant injection system for nuclear reactors wherein a core reflood tank is provided to afford more reliable reflooding of the reactor core in the event of a break in one of the reactor coolant supply loops. Each reactor coolant supply loop is arranged in a separate compartment in the containment structure to contain and control the flow of spilled coolant so as to permit its use during emergency core cooling procedures. A spillway allows spilled coolant in the compartment to pass into the emergency water storage tank from where it can be pumped back to the reactor vessel. (author)

  8. Porous media heat transfer for injection molding

    Science.gov (United States)

    Beer, Neil Reginald

    2016-05-31

    The cooling of injection molded plastic is targeted. Coolant flows into a porous medium disposed within an injection molding component via a porous medium inlet. The porous medium is thermally coupled to a mold cavity configured to receive injected liquid plastic. The porous medium beneficially allows for an increased rate of heat transfer from the injected liquid plastic to the coolant and provides additional structural support over a hollow cooling well. When the temperature of the injected liquid plastic falls below a solidifying temperature threshold, the molded component is ejected and collected.

  9. Shoulder pain: the role of diagnostic injections.

    Science.gov (United States)

    Larson, H M; O'Connor, F G; Nirschl, R P

    1996-04-01

    Many different shoulder disorders cause similar symptoms and pain patterns. An accurate diagnosis can generally be made by obtaining a detailed history, performing a comprehensive, directed physical examination and obtaining selected radiographs. Occasionally, shoulder injections can be of great assistance in establishing a clear diagnosis and providing relief of symptoms. Subacromial space injection, acromioclavicular joint injection, intra-articular injection and injection of the biceps tendon are helpful in identifying such disorders as subacromial bursitis, acromioclavicular arthritis, injury to the glenohumeral joint and bicipital tendinitis.

  10. The LHC injection kicker magnet

    CERN Document Server

    Ducimetière, Laurent; Barnes, M J; Wait, G D

    2003-01-01

    Proton beams will be injected into LHC at 450 GeV by two kicker magnet systems, producing magnetic field pulses of approximately 900 ns rise time and up to 7.86 s flat top duration. One of the stringent design requirements of these systems is a flat top ripple of less than ± 0.5%. Both injection systems are composed of 4 travelling wave kicker magnets of 2.7 m length each, powered by pulse forming networks (PFN's). To achieve the required kick strength of 1.2 Tm, a low characteristic impedance has been chosen and ceramic plate capacitors are used to obtain 5 Omega. Conductive stripes in the aperture of the magnets limit the beam impedance and screen the ferrite. The electrical circuit has been designed with the help of PSpice computer modelling. A full size magnet prototype has been built and tested up to 60 kV with the magnet under ultra high vacuum (UHV). The pulse shape has been precision measured at a voltage of 15 kV. After reviewing the performance requirements the paper presents the magnet...

  11. The RHIC injection fast kicker

    International Nuclear Information System (INIS)

    Forsyth, E.B.; Pappas, G.C.; Tuozzolo, J.E.; Zhang, W.

    1995-01-01

    The purpose of the injection kicker is to provide the ultimate deflection to the incoming beam from the Alternating Gradient Synchrotron (AGS) into the Relativistic Heavy Ion Collider (RHIC). The beam is kicked in the vertical direction to place it on the equilibrium orbit of RHIC. Each bunch in the AGS is transferred separately, and stacked box-car fashion in the appropriate RHIC rf bucket. In order to achieve the required deflection angle four magnets powered by four pulsers will be used for each ring of RHIC. When the bunches are stacked in RHIC the last few rf buckets are left unfilled in order to provide a gap in the beam to facilitate the ejection or beam abort process. This also means there is not a severe constraint on the fall-time of the injection kicker. One prototype pulser has been built and tested. Much of the development effort has gone into the magnet design. Although lumped ferrite magnets are simpler to build and require less power to reach full field, a transmission line magnet was developed because of the very fast rise-time requirement and the tolerances imposed on the field variation and ripple

  12. Injection into electron plasma traps

    International Nuclear Information System (INIS)

    Gorgadze, Vladimir; Pasquini, Thomas A.; Fajans, Joel; Wurtele, Jonathan S.

    2003-01-01

    Computational studies and experimental measurements of plasma injection into a Malmberg-Penning trap reveal that the number of trapped particles can be an order of magnitude higher than predicted by a simple estimates based on a ballistic trapping model. Enhanced trapping is associated with a rich nonlinear dynamics generated by the space-charge forces of the evolving trapped electron density. A particle-in-cell simulation is used to identify the physical mechanisms that lead to the increase in trapped electrons. The simulations initially show strong two-stream interactions between the electrons emitted from the cathode and those reflected off the end plug of the trap. This is followed by virtual cathode oscillations near the injection region. As electrons are trapped, the initially hollow longitudinal phase-space is filled, and the transverse radial density profile evolves so that the plasma potential matches that of the cathode. Simple theoretical arguments are given that describe the different dynamical regimes. Good agreement is found between simulation and theory

  13. Calculation method of water injection forward modeling and inversion process in oilfield water injection network

    Science.gov (United States)

    Liu, Long; Liu, Wei

    2018-04-01

    A forward modeling and inversion algorithm is adopted in order to determine the water injection plan in the oilfield water injection network. The main idea of the algorithm is shown as follows: firstly, the oilfield water injection network is inversely calculated. The pumping station demand flow is calculated. Then, forward modeling calculation is carried out for judging whether all water injection wells meet the requirements of injection allocation or not. If all water injection wells meet the requirements of injection allocation, calculation is stopped, otherwise the demand injection allocation flow rate of certain step size is reduced aiming at water injection wells which do not meet requirements, and next iterative operation is started. It is not necessary to list the algorithm into water injection network system algorithm, which can be realized easily. Iterative method is used, which is suitable for computer programming. Experimental result shows that the algorithm is fast and accurate.

  14. Prevalence and correlates of neck injection among people who inject drugs in Tijuana, Mexico.

    Science.gov (United States)

    Rafful, Claudia; Wagner, Karla D; Werb, Dan; González-Zúñiga, Patricia E; Verdugo, Silvia; Rangel, Gudelia; Strathdee, Steffanie A

    2015-11-01

    Injecting drugs in the neck has been related to adverse health conditions such as jugular vein thrombosis, deep neck infections, aneurysm, haematomas, airway obstruction, vocal cord paralysis and wound botulism, among others. We identified prevalence and correlates of neck injection among people who inject drugs (PWID) in Tijuana, Mexico. Beginning in 2011, PWID aged ≥18 years who injected drugs within the last month were recruited into a prospective cohort. At baseline and semi-annually, PWID completed interviewer-administered surveys soliciting data on drug-injecting practices. Logistic regression was used to identify predictors of injecting in the neck as the most frequent injection site at a single visit. Of 380 PWID, 35.3% injected in the neck at least once in the past 6 months, among whom 71.6% reported it as their most common injection site, the most common injecting site after the arms (47%). Controlling for age, years injecting and injecting frequency, injecting heroin and methamphetamine two or more times per day and having sought injection assistance were associated with injecting in the neck [adjusted odds ratios (AOR): 2.12; 95% confidence intervals (CI): 1.27-3.53 and AOR: 2.65; 95% CI: 1.52-4.53 respectively]. Injecting in the neck was very common among PWID in Tijuana and was associated with polydrug use and seeking injection assistance. Tailoring harm reduction education interventions for individuals who provide injection assistance ('hit doctors') may allow for the dissemination of safe injecting knowledge to reduce injection-related morbidity and mortality. © 2015 Australasian Professional Society on Alcohol and other Drugs.

  15. Characterization of Injection Molded Structures

    DEFF Research Database (Denmark)

    Sun, Ling; Søgaard, Emil; Andersen, Nis Korsgaard

    for different applications. We show how to correlate the structures of the polymer replicas with respect to their functionalities. Furthermore, we introduce how we coordinate with all partners in the “Nanoplast” project, and how we utilize the existing facilities of each method to understand structure......Microscopy has been widely applied to understand surface structures of solid samples. According to the instrumental methodology, there are different microscopy methods: optical microscopy, electron microscopy, and scanning probe microscopy (SPM). These microscopy methods have individual advantages...... and limitations. Therefore, it would be difficult to characterize complex, especially hierarchical structures by using only one method. Here we present a combined optical microscopy, scanning electron microscopy (SEM), and scanning probe microscopy study on injection molded structures. These structures are used...

  16. Sterile Endophthalmitis after Intravitreal Injections

    Directory of Open Access Journals (Sweden)

    Joaquín Marticorena

    2012-01-01

    Full Text Available Sterile endophthalmitis appears as an infrequent complication of intravitreal injections and seems to develop mainly in the context of the off-label use of drugs that have not been conceived for intravitreous administration. The aetiology of sterile endophthalmitis, independently of the administered drug, remains uncertain and a multifactorial origin cannot be discarded. Sterile inflammation secondary both to intravitreal triamcinolone acetonide and to intravitreal bevacizumab share many characteristics such as the acute and painless vision loss present in the big majority of the cases. Dense vitreous opacity is a common factor, while anterior segment inflammation appears to be mild to moderate. In eyes with sterile endophthalmitis, visual acuity improves progressively as the intraocular inflammation reduces without any specific treatment. If by any chance the ophthalmologist is not convinced by the sterile origin of the inflammation, this complication must be treated as an acute endophthalmitis because of the devastating visual prognosis of this intraocular infection in the absence of therapy.

  17. Examination of injection moulded thermoplastic maize starch

    Directory of Open Access Journals (Sweden)

    2007-12-01

    Full Text Available This paper focuses on the effect of the different injection moulding parameters and storing methods on injection moulded thermoplastic maize starch (TPS. The glycerol and water plasticized starch was processed in a twin screw extruder and then with an injection moulding machine to produce TPS dumbbell specimens. Different injection moulding set-ups and storing conditions were used to analyse the effects on the properties of thermoplastic starch. Investigated parameters were injection moulding pressure, holding pressure, and for the storage: storage at 50% relative humidity, and under ambient conditions. After processing the mechanical and shrinkage properties of the manufactured TPS were determined as a function of the ageing time. While conditioning, the characteristics of the TPS changed from a soft material to a rigid material. Although this main behaviour remained, the different injection moulding parameters changed the characteristics of TPS. Scanning electron microscope observations revealed the changes in the material on ageing.

  18. Geothermal Injection Monitoring in Klamath Falls, OR

    Energy Technology Data Exchange (ETDEWEB)

    Culver, G

    1990-01-01

    Klamath Falls has nearly a 150-year history of geothermal utilization. The geothermal aquifer has been the subject of many studies and is probably the most tested direct use reservoir in the world. This provides good background data for increased monitoring needed as new injection wells are drilled. Prior to July 1990, few injection wells existed. A city ordinance requires injection after July 1990. The city and major injectors have initiated a monitoring system.

  19. Autologous Fat Injection for Augmented Mammoplasty

    International Nuclear Information System (INIS)

    Yoon, Eul Sik; Seo, Bo Kyoung; Yi, Ann; Cho, Kyu Ran

    2008-01-01

    Autologous fat injection is one of the methods utilized for augmented mammoplasty methods. In this surgical procedure, the fat for transfer is obtained from the donor site of the patient's own body by liposuction and the fat is then injected into the breast. We report here cases of three patients who underwent autologous fat injection. Two of the patients had palpable masses that were present after surgery. The serial imaging findings and surgical method of autologous fat transfer are demonstrated

  20. Characterization of an intravenously injected bolus

    International Nuclear Information System (INIS)

    Samuel, A.M.; Raikar, U.R.; Atmaram, S.H.; Ganatra, R.D.

    1976-01-01

    A study of some parameters affecting the time activity histogram of an intravenous bolus injection of radioactivity was performed. A scoring system for bolus compactness was attempted. A score of 2 and above was considered to be a satisfactory bolus. Volumes less than 1 ml tended to result in a satisfactory bolus. The nature of radiopharmaceutical injected, different injecters and age of the patient did not affect the score. Thyrotoxic patients gave the best bolus score. (orig.) [de

  1. Cellulitis Developing After Intramuscular Metamizole Injection

    Directory of Open Access Journals (Sweden)

    Onur Ozturk

    2016-12-01

    Full Text Available If the suitable technique is not used in intramuscular injection applications and the injection area is not detected correctly, complications may be observed. Our patient was given intramuscular Metamizole in his house and then he had cellulitis with necrosis area. Following an antibiotic treatment, tissue defect was primarily covered with gluteal muscle skin flap. Cellulitis development after metamizole injection is not common still potential side effects should be considered before prescription.

  2. Non-injection Drug Use and Injection Initiation Assistance among People Who Inject Drugs in Tijuana, Mexico.

    Science.gov (United States)

    Ben Hamida, Amen; Rafful, Claudia; Jain, Sonia; Sun, Shelly; Gonzalez-Zuniga, Patricia; Rangel, Gudelia; Strathdee, Steffanie A; Werb, Dan

    2018-02-01

    Although most people who inject drugs (PWID) report receiving assistance during injection initiation events, little research has focused on risk factors among PWID for providing injection initiation assistance. We therefore sought to determine the influence of non-injection drug use among PWID on their risk to initiate others. We used generalized estimating equation (GEE) models on longitudinal data among a prospective cohort of PWID in Tijuana, Mexico (Proyecto El Cuete IV), while controlling for potential confounders. At baseline, 534 participants provided data on injection initiation assistance. Overall, 14% reported ever initiating others, with 4% reporting this behavior recently (i.e., in the past 6 months). In a multivariable GEE model, recent non-injection drug use was independently associated with providing injection initiation assistance (adjusted odds ratio [AOR] = 2.42, 95% confidence interval [CI] = 1.39-4.20). Further, in subanalyses examining specific drug types, recent non-injection use of cocaine (AOR = 9.31, 95% CI = 3.98-21.78), heroin (AOR = 4.00, 95% CI = 1.88-8.54), and methamphetamine (AOR = 2.03, 95% CI = 1.16-3.55) were all significantly associated with reporting providing injection initiation assistance. Our findings may have important implications for the development of interventional approaches to reduce injection initiation and related harms. Further research is needed to validate findings and inform future approaches to preventing entry into drug injecting.

  3. Injection of Fluids into Supercritical Environments

    National Research Council Canada - National Science Library

    Oschwald, M

    2004-01-01

    This paper summarizes and compares the results of systematic research programs at two independent laboratories regarding the injection of cryogenic liquids at subcritical and supercritical pressures...

  4. Nicolau Syndrome after Intramuscular Injection: 3 Cases

    Directory of Open Access Journals (Sweden)

    Seok-Kwun Kim

    2012-05-01

    Full Text Available Nicolau syndrome is a rare complication of intramuscular injection consisting of ischemic necrosis of skin, soft tissue, and muscular tissue that arises locoregionally. The characteristic pattern is pain around the injection site, developing into erythema, a livedoid dermatitis patch, and necrosis of the skin, subcutaneous fat, and muscle tissue. Three patients were injected with drugs (diclofenac sodium, ketoprofen, meperidine for pain relief. Three patients complained of pain, and a skin lesion was observed, after which necrosis developed on their buttocks. Each patient underwent debridement and coverage. The wound healed uneventfully. We report three cases of Nicolau syndrome in the buttocks following diclofenac intramuscular injection.

  5. Nicolau Syndrome after Intramuscular Benzathine Penicillin Injection

    Directory of Open Access Journals (Sweden)

    Morteza Noaparast

    2014-11-01

    Full Text Available A 3-year-old boy was admitted to the emergency department with right lower limb pain, edema, and livedoid discoloration that occurred immediately after intramuscular injection of benzathine penicillin. The patient was diagnosed with Nicolau syndrome, a rare complication of intramuscular injection presumed to be related to the inadvertent intravascular injection. It was first reported following intramuscular injection of bismuth salt, but it can occur as a complication of various other drugs. Fasciotomy was carried out due to the resultant compartment syndrome and medical therapy with heparin, corticosteroid, and pentoxifyllin was initiated.

  6. The injection and extraction of SSRF booster

    International Nuclear Information System (INIS)

    Li Yuan; Li Haohu; Liu Guimin; Li Deming

    2008-01-01

    The layout of injection and extraction system were introduced in this paper. The horizontal and vertical injection acceptance are about 23 πmm·mrad and 37 πmm·mrad, respectively, while emittance of the injected beam is 9 πmm·mrad (3σ). This ensures the high injection efficiency. Three slow kickers can form a good bump. The inside position of the entrance of septum is set to 15 mm, where the bumped beam and the extraction beam are 10 mm and 22 mm, respectively, far from the booster central orbit. (authors)

  7. Creating fluid injectivity in tar sands formations

    Science.gov (United States)

    Stegemeier, George Leo; Beer, Gary Lee; Zhang, Etuan

    2010-06-08

    Methods for treating a tar sands formation are described herein. Methods for treating a tar sands may include heating a portion of a hydrocarbon layer in the formation from one or more heaters located in the portion. The heat may be controlled to increase the permeability of at least part of the portion to create an injection zone in the portion with an average permeability sufficient to allow injection of a fluid through the injection zone. A drive fluid and/or an oxidizing fluid may be provided into the injection zone. At least some hydrocarbons are produced from the portion.

  8. Hydrogen injection device in BWR type reactor

    International Nuclear Information System (INIS)

    Takagi, Jun-ichi; Kubo, Koji.

    1988-01-01

    Purpose: To reduce the increasing ratio of main steam system dose rate due to N-16 activity due to excess hydrogen injection in the hydrogen injection operation of BWR type reactors. Constitution: There are provided a hydrogen injection mechanism for injecting hydrogen into primary coolants of a BWR type reactor, and a chemical injection device for injecting chemicals such as methanol, which makes nitrogen radioisotopes resulted in the reactor water upon hydrogen injection non-volatile, into the pressure vessel separately from hydrogen. Injected hydrogen and the chemicals are not reacted in the feedwater system, but the reaction proceeds due to the presence of radioactive rays after the injection into the pressure vessel. Then, hydrogen causes re-combination in the downcomer portion to reduce the dissolved oxygen concentration. Meanwhile, about 70 % of the chemicals is supplied by means of a jet pump directly to the reactor core, thereby converting the chemical form of N-16 in the reactor core more oxidative (non-volatile). (Kawakami, Y.)

  9. DC injection into low voltage AC networks

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    This report summarises the results of a study investigating the impact of levels of injected DC current injections on a low voltage AC distribution network systems in order to recommend acceptable limits of DC from microgeneration. Relevant literature is reviewed, and the impact of DC levels in distribution transformers, transformer modelling, and instrumental transformers are discussed. The impact of DC in residual current devices (RCD) and in domestic electricity watt hour meters is examined along with DC enhanced corrosion, corrosion failure, and the measurement of DC current injection. Sources of DC injection outlined include DC from computer power supplies, network faults, geomagnetic phenomena, lighting circuits/dimmers, and embedded generators.

  10. Prevalence of injections and knowledge of safe injections among rural residents in Central China.

    Science.gov (United States)

    Yan, Y W; Yan, J; Zhang, G P; Gao, Z L; Jian, H X

    2007-08-01

    Abuse of the injection services, namely unnecessary injections and unsafe injections, exists extensively in developing countries. Unsafe injection practices contribute to the transmission of blood-borne pathogens. The aims of this study were to survey the prevalence of injections and knowledge of injection safety among the rural residents in Jingzhou district, Hubei, China and to provide scientific data for developing a health educational programme. A retrospective cross-sectional study was conducted in 12 villages, which were selected from the Jingzhou district by the random sampling method. 50 rural residents were interviewed per village using a questionnaire. Among the 595 residents studied, 192 had received at least one injection in the past three months, with an injection prevalence of 32.3 percent and an average of 0.93 injections. 90.3 percent of the rural residents knew that unsafe injections could transmit the following blood-borne pathogens: human immunodeficiency virus (74.4 percent), hepatitis B virus (55.8 percent) and hepatitis C virus (22.9 percent). Logistic regression analysis showed that the residents' age, educational level and residential area were important factors in influencing their knowledge about injection safety. The results indicated that the injection prevalence was high among rural residents in the study area, and their knowledge regarding injection safety should be further improved.

  11. "Injection first": a unique group of injection drug users in Tijuana, Mexico.

    Science.gov (United States)

    Morris, Meghan D; Brouwer, Kimberly C; Lozada, Remedios M; Gallardo, Manuel; Vera, Alicia; Strathdee, Steffanie A

    2012-01-01

    Using baseline data from a study of injection drug users (IDUs) in Tijuana, Mexico (N = 1,052), we identified social and behavioral factors associated with injecting at the same age or earlier than other administration routes of illicit drug use (eg, "injection first") and examined whether this IDU subgroup had riskier drug using and sexual behaviors than other IDUs. Twelve-percent "injected first." Characteristics independently associated with a higher odds of "injection first" included being younger at first injection, injecting heroin as their first drug, being alone at the first injection episode, and having a sexual debut at the same age or earlier as when they initiated drug use; family members' illicit drug use was associated with lower odds of injecting first. When adjusting for age at first injection and number of years injecting, "injection first" IDUs had lower odds of ever overdosing, and ever trading sex. On the other hand, they were less likely to have ever been enrolled in drug treatment, and more commonly obtained their syringes from potentially unsafe sources. In conclusion, a sizable proportion of IDUs in Tijuana injected as their first drug using experience, although evidence that this was a riskier subgroup of IDUs was inconclusive.  Copyright © American Academy of Addiction Psychiatry.

  12. Injective Labeled Oriented Trees are Aspherical

    OpenAIRE

    Harlander, Jens; Rosebrock, Stephan

    2012-01-01

    A labeled oriented tree is called injective if each generator occurs at most once as an edge label. We show that injective labeled oriented trees are aspherical. The proof relies on a new relative asphericity test based on a lemma of Stallings.

  13. Pellet injection into ASDEX upgrade plasmas

    International Nuclear Information System (INIS)

    Lang, P.T.; Zohm, H.; Buechl, K.; Fuchs, J.C.; Gehre, O.; Gruber, O.; Lang, R.S.; Mertens, V.; Neuhauser, J.; Salzmann, H.

    1996-04-01

    This work comprises results obtained using the new centrifuge injection system for the two first years of pellet injection experiments at Asdex Upgrade until the end of the 1995 experimental campaign. The main aim of the pellet injection investigation is to develop scenarios allowing for a more flexible plasma density control means of injection of cryogenic solid hydrogen pellets. Efforts have been made to develop scenarios allowing more flexible plasma density control by injecting cryogenic solid hydrogen pellets. While the injection of pellets during ohmic discharges was found to be most efficient and also improves the plasma performance, increasing the auxiliary heating power causes a detoriation of the pellet fuelling efficiency. A further strong reduction of the pellet fuelling efficiency by an additional process was observed for the more reactor-relevant conditions of shallow particle deposition during H-mode phases. With injection during type I ELMy H-mode phases, each pellet was found to trigger the release of an ELM and therefore cause particle losses mainly from the edge region. In the type I ELMy H-mode, only sufficient pellet penetration allowed noticeable, persistent particle deposition in the plasma by the pellets. Applying adequate pellet injection conditions and favourable scenarios using combined pellet/gas puff refuelling, significant density ramp-up to densities exceeding the empirical Greenwald limit by up to a factor of two was achieved even for strongly heated H-mode plasmas. (orig.)

  14. Children conceived after intracytoplasmic sperm injection (ICSI)

    DEFF Research Database (Denmark)

    Mau, C; Juul, A; Main, K M

    2004-01-01

    The aim of the study was to evaluate current medical knowledge about children born after intracytoplasmic sperm injection (ICSI) with respect to congenital malformations, chromosome abnormalities and postnatal growth.......The aim of the study was to evaluate current medical knowledge about children born after intracytoplasmic sperm injection (ICSI) with respect to congenital malformations, chromosome abnormalities and postnatal growth....

  15. The energetic ion substorm injection boundary

    International Nuclear Information System (INIS)

    Lopez, R.E.; Sibeck, D.G.; McEntire, R.W.; Krimigis, S.M.

    1990-01-01

    The substorm injection boundary model has enjoyed considerable success in explaining plasma signatures in the near-geosynchronous region. However, the injection boundary has remained primarily a phenomenological model. In this paper the authors examine 167 dispersionless energetic ion injections which were observed by AMPTE CCE. The radial and local time distribution of the events as a function of Kp is qualitatively similar to that envisioned in the injection boundary model of Mauk and McIlwain (1974). They argue that particles observed during dispersionless injections are locally energized during the disruption of the cross-tail current sheet. Therefore they identify the injection boundary, as derived from the spatial distribution of dispersionless injections, with the earthward edge of the region of the magnetotail which undergoes current sheet disruption during the substorm expansion phase. The authors show that this qualitative model for the generation of the injection boundary can provide an explanation for the dispersionless nature, the double spiral shape, and the Kp dependence of the boundary

  16. Closure of shallow underground injection wells

    International Nuclear Information System (INIS)

    Veil, J.A.; Grunewald, B.

    1993-01-01

    Shallow injection wells have long been used for disposing liquid wastes. Some of these wells have received hazardous or radioactive wastes. According to US Environmental Protection Agency (EPA) regulations, Class IV wells are those injection wells through which hazardous or radioactive wastes are injected into or above an underground source of drinking water (USDW). These wells must be closed. Generally Class V wells are injection wells through which fluids that do not contain hazardous or radioactive wastes are injected into or above a USDW. Class V wells that are responsible for violations of drinking water regulations or that pose a threat to human health must also be closed. Although EPA regulations require closure of certain types of shallow injection wells, they do not provide specific details on the closure process. This paper describes the regulatory background, DOE requirements, and the steps in a shallow injection well closure process: Identification of wells needing closure; monitoring and disposal of accumulated substances; filling and sealing of wells; and remediation. In addition, the paper describes a major national EPA shallow injection well enforcement initiative, including closure plan guidance for wells used to dispose of wastes from service station operations

  17. Intentional intravenous mercury injection | Yudelowitz | South African ...

    African Journals Online (AJOL)

    Intravenous mercury injection is rarely seen, with few documented cases. Treatment strategies are not clearly defined for such cases, although a few options do show benefit. This case report describes a 29-year-old man suffering from bipolar disorder, who presented following self-inflicted intravenous injection of mercury.

  18. Charge Injection and Transport in Organic Nanofibers

    DEFF Research Database (Denmark)

    Kjelstrup-Hansen, Jakob; Bøggild, Peter; Rubahn, H. G.

    2007-01-01

    the injection barrier height equal to the difference between the metal electrode work function and the HOMO energy level of the organic semiconductor. Semiquantitative modeling suggests that the weak temperature dependence is due to injection into a distribution of states rather than into a single energy level...

  19. Injection Molding of High Aspect Ratio Nanostructures

    DEFF Research Database (Denmark)

    Matschuk, Maria; Larsen, Niels Bent

    We present a process for injection molding of 40 nm wide and >100 nm high pillars (pitch: 200 nm). We explored the effects of mold coatings and injection molding conditions on the replication quality of nanostructures in cyclic olefin copolymer. We found that optimization of molding parameters...

  20. Necrotizing Soft Tissue Fasciitis after Intramuscular Injection

    Directory of Open Access Journals (Sweden)

    Angelica Abbate

    2018-01-01

    Full Text Available Necrotizing soft tissue fasciitis (NSTIs or necrotizing fasciitis is an infrequent and serious infection. Herein, we describe the clinical course of a female patient who received a diagnosis of NSTIs after gluteus intramuscular injection. We also report the results of our review of published papers from 1997 to 2017. Since now, 19 cases of NSTIs following intramuscular injections have been described. We focus on the correlation between intramuscular injection and NSTIs onset, especially in immunosuppressed patients treated with corticosteroids, suffering from chronic diseases or drug addicted. Intramuscular injections can provoke severe tissue trauma, representing local portal of infection, even if correctly administrated. Otherwise, it is important not to inject drug in subcutaneous, which is a less vascularized area and therefore more susceptible to infections. Likewise, a proper injecting technique and aspiration prior to injection seem to be valid measure to prevent intra-arterial or para-arterial drug injection with the consequent massive inflammatory reaction. Necrosis at the infection site appears to be independent of the drug, and it is a strong additional risk factor for NSTIs.

  1. Injection Technique and Pen Needle Design Affect Leakage From Skin After Subcutaneous Injections

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente; Jensen, Morten Lind

    2016-01-01

    BACKGROUND: After a subcutaneous injection fluid might leak out of the skin, commonly referred to as leakage or backflow. The objective was to examine the influence of needle design and injection technique on leakage after injections in the subcutaneous tissue of humans and pigs. METHOD: Leakage ...

  2. Injection of tennis elbow: Hit and miss? A cadaveric study of injection accuracy

    NARCIS (Netherlands)

    Keijsers, Renee; van den Bekerom, Michel P. J.; Koenraadt, Koen L. M.; Bleys, Ronald L. A. W.; van Dijk, C. Niek; Eygendaal, Denise; van Riet, Roger; Middernacht, Bart; Defoort, Saartje; Wagener, Marc; Harake, Ramzi; Ciornohac, Jean-Florin; Montarnal, Robert; van Benthem, Yasmin; Cattaneo, Stefano; Faber, Dirk; Galatz, Leesa; Birkisson, Illugi; van der Hoeven, Henk; Witjes, Suzanne; Heeren, M.; Ahmed, El-Gammal; Husif, N. N.; Beumer, Annechien; The, Bertram

    2017-01-01

    Different injection therapies are used in the treatment of lateral epicondylitis (LE). Usually, the extensor carpi radialis brevis (ECRB) tendon is affected. Therefore, an injection should be aimed at the origin of this tendon. This study demonstrates the accuracy of manual injections in the

  3. 77 FR 26755 - Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for...

    Science.gov (United States)

    2012-05-07

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9669-6] Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for Exemption--Class I Hazardous Waste Injection; Diamond... reissuance of an exemption to the land disposal Restrictions, under the 1984 Hazardous and Solid Waste...

  4. 76 FR 55908 - Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for...

    Science.gov (United States)

    2011-09-09

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9461-5] Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for Exemption--Class I Hazardous Waste Injection; Great Lakes... of an exemption to the land disposal restrictions, under the 1984 Hazardous and Solid Waste...

  5. 76 FR 42125 - Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for...

    Science.gov (United States)

    2011-07-18

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9440-3] Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for Exemption--Class I Hazardous Waste Injection; ConocoPhillips... Restrictions, under the 1984 Hazardous and Solid Waste Amendments to the Resource Conservation and Recovery Act...

  6. 76 FR 36129 - Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for...

    Science.gov (United States)

    2011-06-21

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9321-3] Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for Exemption--Class I Hazardous Waste Injection; ExxonMobil... disposal Restrictions, under the 1984 Hazardous and Solid Waste Amendments to the Resource Conservation and...

  7. 78 FR 76294 - Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for...

    Science.gov (United States)

    2013-12-17

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9904-21-OW] Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for Exemption--Class I Hazardous Waste Injection; Mosaic... Restrictions, under the 1984 Hazardous and Solid Waste Amendments to the Resource Conservation and Recovery Act...

  8. 75 FR 60457 - Underground Injection Control Program Hazardous Waste Injection Restrictions; Petition for...

    Science.gov (United States)

    2010-09-30

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9208-4] Underground Injection Control Program Hazardous Waste Injection Restrictions; Petition for Exemption--Class I Hazardous Waste Injection Dow Chemical Company (DOW... 1984 Hazardous and Solid Waste Amendments to the Resource Conservation and Recovery Act have been...

  9. 78 FR 42776 - Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for...

    Science.gov (United States)

    2013-07-17

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL9834-8] Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for Exemption--Class I Hazardous Waste Injection; Blanchard Refining... disposal Restrictions, under the 1984 Hazardous and Solid Waste Amendments to the Resource Conservation and...

  10. 77 FR 52717 - Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for...

    Science.gov (United States)

    2012-08-30

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9724-1] Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for Exemption--Class I Hazardous Waste Injection; Cornerstone... exemption to the land disposal Restrictions, under the 1984 Hazardous and Solid Waste Amendments to the...

  11. 77 FR 71006 - Sodium Nitrite Injection and Sodium Thiosulfate Injection Drug Products Labeled for the Treatment...

    Science.gov (United States)

    2012-11-28

    ... poisoning and unapproved injectable drug products containing sodium thiosulfate labeled for the treatment of... for the treatment of cyanide poisoning are new drugs that require approved new drug applications (NDAs... Injection and Sodium Thiosulfate Injection drug product, labeled for treatment of acute cyanide poisoning...

  12. Deuterium pellet injection in the TFR Tokamak

    International Nuclear Information System (INIS)

    Lazare, O.

    1985-07-01

    Injecting fresh fuel deep inside the plasma of a thermonuclear reactor appears to be necessary; the only way to do that is to inject fast solid deuterium pellets. The existing theoretical, technical and experimental aspects of this method are presented. The experiments on TFR have confirmed that injecting pellets is technically feasible; a new kind of injector is presented. The injection does not degrade stability nor confinement of the plasma. The study of the transient phenomena occuring during the injection has proved to be an efficient way to investigate particles and energy transport in the discharge; in particular, a fast transport phenomenon, similar to those occuring during disruptions, has been studied in details. Conclusions about disruptions are drawn. (Ref 101) [fr

  13. Advanced diesel electronic fuel injection and turbocharging

    Science.gov (United States)

    Beck, N. J.; Barkhimer, R. L.; Steinmeyer, D. C.; Kelly, J. E.

    1993-12-01

    The program investigated advanced diesel air charging and fuel injection systems to improve specific power, fuel economy, noise, exhaust emissions, and cold startability. The techniques explored included variable fuel injection rate shaping, variable injection timing, full-authority electronic engine control, turbo-compound cooling, regenerative air circulation as a cold start aid, and variable geometry turbocharging. A Servojet electronic fuel injection system was designed and manufactured for the Cummins VTA-903 engine. A special Servojet twin turbocharger exhaust system was also installed. A series of high speed combustion flame photos was taken using the single cylinder optical engine at Michigan Technological University. Various fuel injection rate shapes and nozzle configurations were evaluated. Single-cylinder bench tests were performed to evaluate regenerative inlet air heating techniques as an aid to cold starting. An exhaust-driven axial cooling air fan was manufactured and tested on the VTA-903 engine.

  14. Self-injection is a success

    DEFF Research Database (Denmark)

    Jensen, Jonna Gintberg; Høi, Henriette Brahe

    these people have so far received injections from their own doctor. Many of the 29 feel healthy, are on the labor market and live a normal life. Therefore, it may be a recurring nuisance having to consult their physician monthly to get the injection. On this background, it is believed that self......-injection will increase the individual's quality of life. For that reason this project on quality assurance of the 29 citizens current quality of life, if they want training for self-administration in our hospital unit, and follow-up contact about how self-injections are going on. Method for data generation: Data...... out qualitative interviews Transcription of interview material Follow-up telephone interviews Analysis (Steiner Kvale's three operational levels) Significant findings: Causes of training for self-administration is desired. Family doctor injects quickly – which gives bruising, and may bleed profusely...

  15. Percutaneous spine injection: considerations for improving treatment

    International Nuclear Information System (INIS)

    Lee, Joon Woo; Kim, Sung Hyun; Lee, In Sook; Choi, Jung Ah; Yoon, Chang Jin; Hwang, Sung Il; Kang, Heung Sik; Choi, Ja Young; Koh, Young Hwan; Hong, Sung Hwan

    2005-01-01

    To discuss the causes of treatment failure in percutaneous spine injections for low back pain or radiculopathy by analyzing patients who have experienced negative treatment effect on their first visit and a positive treatment effect on their second visit. The authors reviewed the cases of 24 patients who visited the pain intervention outpatient department in our hospital due to back pain or radiculopathy. All patients reviewed experienced a negative treatment effect following their first spine injection, but a positive treatment effect following the second injection. The dates of the cases range from June 2003 to May 2004. Two radiologists analyzed the possible causes of the negative treatment effect following the first injection therapies by considering clinical aspects as well as reviewing radiological images. The most common condition was the presence of the change in the level of the second selective nerve root block (n=13). In seven cases, the methods for administering the injections were changed to facet block (n=2), midline epidural block (n=1), selective nerve root block (n=3) and caudal epidural block (n=1). In four cases, there were no changes in the methods for administering the injections nor were there any changes in the level of the selective nerve root block between first and second visit. In those cases, after reviewing spot radiographs performed during injection, we attributed the causes of failure of injection therapy to an inappropriate distribution of drugs. We can improve the effect of percutaneous spine injections for low back pain or radioculopathy by determining the exact level of perineural root block, trying alternative methods, and insuring a good distribution of the injected drugs

  16. Assessment of complications due to intratympanic injections

    Directory of Open Access Journals (Sweden)

    Yu-Chuan Liu

    2016-03-01

    Full Text Available Objective: The purpose of the study is to report and to analyze the complications following intratympanic injections (ITI of steroids. The occurrence rate of complications at different ITI sites, four quadrants of eardrum, was also compared. Methods: A retrospective clinical review in a medical center. Each patient received ITI twice in a week for 2–3 consecutive weeks as a salvage therapy for sudden sensorineural hearing loss. Post-injection complications, especially transient dizziness and vertigo, were recorded. Patients with acute or chronic vertigo episodes in 1 month were excluded. Results: A total of 59 patients with sudden sensorineural hearing loss and a total of 278 times of ITI were performed in 1 year. The post-injection complications included pain, tongue numbness, transient dizziness, vertigo, tinnitus, and a small persistent perforation. There was no significant difference in the occurrence of these complications between the injections sites on the 4 quadrants of the tympanic membrane. However, there was statistical significance in the post-injection vertiginous episode after IT injections to posterior-inferior quadrant (Q3 and posterior-superior quadrant (Q4 compared to anterior-superior quadrant (Q1 and anterior-inferior quadrant (Q2 (P = 0.0113. Conclusion: IT injection is recommended to be applied to the Q2 since the Q1 and Q4 injections are more likely to induce the adverse effect of tongue numbness, while the Q3 and Q4 areas are more likely to induce post-injection vertigo. Keywords: Intratympanic injection, Sudden deafness, Complications, Vertigo

  17. Blindness following cosmetic injections of the face.

    Science.gov (United States)

    Lazzeri, Davide; Agostini, Tommaso; Figus, Michele; Nardi, Marco; Pantaloni, Marcello; Lazzeri, Stefano

    2012-04-01

    Complications following facial cosmetic injections have recently heightened awareness of the possibility of iatrogenic blindness. The authors conducted a systematic review of the available literature to provide the best evidence for the prevention and treatment of this serious eye injury. The authors included in the study only the cases in which blindness was a direct consequence of a cosmetic injection procedure of the face. Twenty-nine articles describing 32 patients were identified. In 15 patients, blindness occurred after injections of adipose tissue; in the other 17, it followed injections of various materials, including corticosteroids, paraffin, silicone oil, bovine collagen, polymethylmethacrylate, hyaluronic acid, and calcium hydroxyapatite. Some precautions may minimize the risk of embolization of filler into the ophthalmic artery following facial cosmetic injections. Intravascular placement of the needle or cannula should be demonstrated by aspiration before injection and should be further prevented by application of local vasoconstrictor. Needles, syringes, and cannulas of small size should be preferred to larger ones and be replaced with blunt flexible needles and microcannulas when possible. Low-pressure injections with the release of the least amount of substance possible should be considered safer than bolus injections. The total volume of filler injected during the entire treatment session should be limited, and injections into pretraumatized tissues should be avoided. Actually, no safe, feasible, and reliable treatment exists for iatrogenic retinal embolism. Nonetheless, therapy should theoretically be directed to lowering intraocular pressure to dislodge the embolus into more peripheral vessels of the retinal circulation, increasing retinal perfusion and oxygen delivery to hypoxic tissues. Risk, V.

  18. Bolus injections of measured amounts of radioactivity

    International Nuclear Information System (INIS)

    Wesolowski, C.A.; Hogendoorn, P.; Vandierendonck, R.; Driedger, A.A.

    1988-01-01

    Many time-based radionuclide techniques, such as glomerular filtration rate measurement (GFR), require prompt intravenous delivery of and accurately measured tracer bolus with minimal residual tracer retention at the injection site. The quality assurance aspects of two antecubital vein, quantitative injection techniques were investigated. A flush bolus technique using a tuberculin syringe piggybacked onto a 10-ml saline flush was compared to a single blood pressure cuff injection technique. Scintillation camera data for each technique were compared for bolus duration in the abdominal aorta and for residual activity at the injection site at 5 min. Bolus times were measured as the FWHM of the gamma variate fit to the abdominal aortic regional time-activity curves. Relatively little focal activity was seen in the antecubital injection site following the flush bolus: marked residual activity was seen following the blood pressure cuff injections. The injection site/arm background ratios averaged 1.3 for the flush bolus and 30.1 for the cuff technique. Although both methods allowed accurate in vitro determination of administered radioactivity, only the tuberculin syringe flush bolus technique was acceptable for time-based quantitation because of its superior in vivo characteristics

  19. In-situ combustion with solvent injection

    Energy Technology Data Exchange (ETDEWEB)

    D' Silva, J.; Kakade, G. [Society of Petroleum Engineers, Kuala Lumpur (Malaysia)]|[Maharashtra Inst. of Technology, Pune (India)

    2008-10-15

    The effects of combining in situ combustion and heavy hydrocarbon naphtha vapor injection techniques in a heavy oil reservoir were investigated. Oil production rates and steam injection efficiencies were considered. The technique was also combined with toe-to-heel air injection (THAI) processes. The study showed that the modified THAI process achieved high rates of recovery for both primary production and as a follow-up technique in partially depleted reservoirs after cyclic steam and cold production. Oil produced using the modified THAI technique was also partially upgraded by the process. Results of the vapour chamber pressure calculations showed that the volume of oil produced by naphtha assisted gravity drainage was between 1 to 3 times higher than amounts of oil produced by SAGD processes during the same amount of time. The naphtha injection process produced more oil than the steam only process. However, high amounts of naphtha were needed to produce oil. Injection and production rates during the naphtha injection process were higher. Naphtha vapor was injected near the heel of a horizontal producer well. The vapor acted as a thermal and diluent mechanism in order to reduce the viscosity of the heavy oil . 9 refs., 4 tabs., 6 figs.

  20. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    Science.gov (United States)

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    In the perioperative period, anesthesiologists and postanesthesia care unit (PACU) nurses routinely prepare and administer small-volume IV injections, yet the accuracy of delivered medication volumes in this setting has not been described. In this ex vivo study, we sought to characterize the degree to which small-volume injections (≤0.5 mL) deviated from the intended injection volumes among a group of pediatric anesthesiologists and pediatric postanesthesia care unit (PACU) nurses. We hypothesized that as the intended injection volumes decreased, the deviation from those intended injection volumes would increase. Ten attending pediatric anesthesiologists and 10 pediatric PACU nurses each performed a series of 10 injections into a simulated patient IV setup. Practitioners used separate 1-mL tuberculin syringes with removable 18-gauge needles (Becton-Dickinson & Company, Franklin Lakes, NJ) to aspirate 5 different volumes (0.025, 0.05, 0.1, 0.25, and 0.5 mL) of 0.25 mM Lucifer Yellow (LY) fluorescent dye constituted in saline (Sigma Aldrich, St. Louis, MO) from a rubber-stoppered vial. Each participant then injected the specified volume of LY fluorescent dye via a 3-way stopcock into IV tubing with free-flowing 0.9% sodium chloride (10 mL/min). The injected volume of LY fluorescent dye and 0.9% sodium chloride then drained into a collection vial for laboratory analysis. Microplate fluorescence wavelength detection (Infinite M1000; Tecan, Mannedorf, Switzerland) was used to measure the fluorescence of the collected fluid. Administered injection volumes were calculated based on the fluorescence of the collected fluid using a calibration curve of known LY volumes and associated fluorescence.To determine whether deviation of the administered volumes from the intended injection volumes increased at lower injection volumes, we compared the proportional injection volume error (loge [administered volume/intended volume]) for each of the 5 injection volumes using a linear

  1. IAEA technical committee meeting on pellet injection

    International Nuclear Information System (INIS)

    1993-01-01

    The IAEA Technical Committee Meeting on Pellet Injection, May 10-12, 1993, at the Japan Atomic Energy Research Institute, Naka, Ibaraki-ken, Japan, was held to review the latest results on pellet injection and its effects on plasma confinement. In particular, topics included in the meeting include (i) pellet ablation and particle fueling results, (ii) pellet injection effects on confinement, including improved confinement modes, edge effects, magnetohydrodynamic activity and impurity transport, and (iii) injector technology and diagnostics using pellets. About 30 experts attended and 23 papers were presented. Refs, figs and tabs

  2. Alkaline sorbent injection for mercury control

    Science.gov (United States)

    Madden, Deborah A.; Holmes, Michael J.

    2002-01-01

    A mercury removal system for removing mercury from combustion flue gases is provided in which alkaline sorbents at generally extremely low stoichiometric molar ratios of alkaline earth or an alkali metal to sulfur of less than 1.0 are injected into a power plant system at one or more locations to remove at least between about 40% and 60% of the mercury content from combustion flue gases. Small amounts of alkaline sorbents are injected into the flue gas stream at a relatively low rate. A particulate filter is used to remove mercury-containing particles downstream of each injection point used in the power plant system.

  3. Vibration of safety injection pump motors

    Energy Technology Data Exchange (ETDEWEB)

    Wattrelos, D.

    1996-12-01

    This paper covers a fault encountered in the safety injection pump motors of the French 900 MWe unit nuclear power stations. This fault was not revealed either during the low pressure safety injection and containment spray system pump qualification tests under accident conditions or during the special tests on a test bench carried out to attempt to replicate the fault and to identify ways of remedying it. This constitutes a potential common mode of failure of the safety injection system and the containment spray system pumps. The vibration phenomena illustrate the importance of carrying out tests in the plants under conditions as close as possible to those of actual accident situations.

  4. [Rational motivation of drug injection and prostitution].

    Science.gov (United States)

    Beauchamp, Sylvie

    2003-01-01

    Homeless drug users and prostitutes constitute a population at risk for contracting and propagating AIDS. This study aims at understanding the paradox related to drug injection and prostitution among 21 homeless from Montreal. These behaviors are studied following the picoeconomic paradox of an apprehended desire. The results show that these homeless see drug injection as a self-reward motivated by imaginary emotional object, in spite of the known and dreaded consequences. Prostitution is described as a self-investment accessory to drug injection. This study concludes with reflections on AIDS prevention programs in relation with the needs of the homeless.

  5. Vibration of safety injection pump motors

    International Nuclear Information System (INIS)

    Wattrelos, D.

    1997-01-01

    This paper covers a fault encountered in the safety injection pump motors of the French 900 MWe unit nuclear power stations. This fault was not revealed either during the low pressure safety injection and containment spray system pump qualification test under accident conditions or during the special tests on a test bench carried out to attempt to replicate the fault and to identify ways of remedying it. This constitutes a potential common mode of failure of the safety injection system and the containment spray system pumps. The vibration phenomena illustrate the importance of carrying out test in the plants under conditions as close as possible to those of actual accident. (author)

  6. Vibration of safety injection pump motors

    International Nuclear Information System (INIS)

    Wattrelos, D.

    1996-01-01

    This paper covers a fault encountered in the safety injection pump motors of the French 900 MWe unit nuclear power stations. This fault was not revealed either during the low pressure safety injection and containment spray system pump qualification tests under accident conditions or during the special tests on a test bench carried out to attempt to replicate the fault and to identify ways of remedying it. This constitutes a potential common mode of failure of the safety injection system and the containment spray system pumps. The vibration phenomena illustrate the importance of carrying out tests in the plants under conditions as close as possible to those of actual accident situations

  7. Injection moulding for macro and micro products

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul

    used for macro products but with the ages it is going deep into the micro areas having machine and process improvements. Extensive research work on injection moulding is going on all over the world. New ideas are flowing into the machines, materials and processes. The technology has made significant......The purpose of the literature survey is to investigate the injection moulding technology in the macro and micro areas from the basic to the state-of-the-art recent technology. Injection moulding is a versatile production process for the manufacturing of plastic parts and the process is extensively...

  8. Massive Preperitoneal Hematoma after a Subcutaneous Injection

    Directory of Open Access Journals (Sweden)

    Hideki Katagiri

    2016-01-01

    Full Text Available Preperitoneal hematomas are rare and can develop after surgery or trauma. A 74-year-old woman, receiving systemic anticoagulation, developed a massive preperitoneal hematoma after a subcutaneous injection of teriparatide using a 32-gauge, 4 mm needle. In this patient, there were two factors, the subcutaneous injection of teriparatide and systemic anticoagulation, associated with development of the hematoma. These two factors are especially significant, because they are widely used clinically. Although extremely rare, physicians must consider this potentially life-threatening complication after subcutaneous injections, especially in patients receiving anticoagulation.

  9. J-regular rings with injectivities

    OpenAIRE

    Shen, Liang

    2010-01-01

    A ring $R$ is called a J-regular ring if R/J(R) is von Neumann regular, where J(R) is the Jacobson radical of R. It is proved that if R is J-regular, then (i) R is right n-injective if and only if every homomorphism from an $n$-generated small right ideal of $R$ to $R_{R}$ can be extended to one from $R_{R}$ to $R_{R}$; (ii) R is right FP-injective if and only if R is right (J, R)-FP-injective. Some known results are improved.

  10. Botulinum toxin injection in laryngeal dyspnea.

    Science.gov (United States)

    Woisard, Virginie; Liu, Xuelai; Bes, Marie Christine Arné; Simonetta-Moreau, Marion

    2017-02-01

    Data, regarding the use of botulinum toxin (BT-A) in laryngeal dyspnea, are scarce, coming from some cases reports in the literature, including Vocal fold paralysis, laryngeal dystonia, vocal cord dysfunction also called paradoxical motion of the vocal fold (PMVF), and post-neuroleptic laryngeal dyskinesia. There is no consensus regarding the muscles and the doses to inject. The aim of this study is to present a retrospective review of patients treated in our ENT Department by BT-A injection in this indication. This study is a retrospective study describing patients who underwent an injection of botulinum toxin for laryngeal dyspnea in the ENT Department from 2005 to 2015 years. The inclusion criteria were a dyspnea associated with a laryngeal dysfunction, confirmed by flexible fiberoptic nasopharyngolaryngoscopy. Information concerning the causes of the dyspnea, the botulinum toxin BT-A injections procedure, post-injection follow-up, and respiratory outcome were collected for all patients included. In the group of 13 patients included, the main cause identified as principal factor linked with the short breath was: a bilateral VF paralysis (Patel et al., Otolaryngol Head Neck Surg 130:686-689, 7), laryngeal dystonia (Balkissoon and Kenn, Semin Respir Crit Care Med 33:595-605, 2), Anxiety syndrome associated with unilateral vocal fold paralysis or asthma (Marcinow et al., Laryngoscope 124:1425-1430, 3), and an isolated asthma (Zwirner et al., Eur Arch Otorhinolaryngol 254:242-245, 1). Nine out of the thirteen patients were improved by the injections. A BT-A-induced stable benefit for four patients led them to stop the injections in the follow-up. Good outcome was observed in five other patients (main cause: bilateral VP paralysis), allowing a progressive lengthening of the delay between BT-A injections. Four patients did not report a positive risk/benefit ratio after BT-A injections; two of them (with bilateral VF paralysis), because of respiratory side effects and

  11. Mechanical design of injection line for VEC

    International Nuclear Information System (INIS)

    Nandi, C.; Bandopadhyay, D.K.; Pal, G.; Sharma, R.N.; Mallik, C.; Chaudhuri, J.; Bhandari, R.K.

    2003-01-01

    A 14.5 GHz ECR ion source along with its analyzing section was earlier installed at VECC for injecting multiply charged gaseous and metallic ions into the existing K 130 cyclotron. The injection line from this ECR ion source was connected to the vertical section of the existing injection line for integrating it with the K 130 cyclotron. The injection line comprises two solenoid magnets, a steering magnet, and a bending magnet. In between the solenoid magnets a length about 1.5 metres has been provided for future atomic physics experimental applications. Two gate valves are used to isolate this area. For beam diagnostics, two Faraday cups, designed and fabricated in this centre, have been installed

  12. Medicines, injections, and supplements for arthritis

    Science.gov (United States)

    Arthritis - medications; Arthritis - steroid injections; Arthritis - supplements; Arthritis - hyaluronic acid ... the-counter pain relievers can help with your arthritis symptoms. "Over-the-counter" means you can buy ...

  13. Steam Injection For Soil And Aquifer Remediation

    Science.gov (United States)

    The purpose of this Issue Paper is to provide to those involved in assessing remediation technologies for specific sites basic technical information on the use of steam injection for the remediation of soils and aquifers that are contaminated by...

  14. LABORATORY SCALE STEAM INJECTION TREATABILITY STUDIES

    Science.gov (United States)

    Laboratory scale steam injection treatability studies were first developed at The University of California-Berkeley. A comparable testing facility has been developed at USEPA's Robert S. Kerr Environmental Research Center. Experience has already shown that many volatile organic...

  15. Injection and extraction techniques in circular accelerators

    International Nuclear Information System (INIS)

    Tang Jingyu

    2008-01-01

    Injection and extraction are usually the key systems in circular accelerators. They play important roles in transferring the beam from one stage acceleration to the other or to experimental stations. It is also in the injection and extraction regions where beam losses happen mostly. Due to the tight space and to reduce the perturbation to the circulating orbit, the devices are usually designed to meet special requirements such as compactness, small stray field, fast rise time or fall time, etc. Usual injection and extraction devices include septum magnets, kicker magnets, electrostatic deflectors, slow bump magnets and strippers. In spite of different accelerators and specification for the injection and extraction devices, many techniques are shared in the design and manufacturing. This paper gives a general review on the techniques employed in the major circular accelerators in China. (authors)

  16. Boundaries, injective envelopes, and reduced crossed products

    DEFF Research Database (Denmark)

    Bryder, Rasmus Sylvester

    In this dissertation, we study boundary actions, equivariant injective envelopes, as well as theideal structure of reduced crossed products. These topics have recently been linked to thestudy of C-simple groups, that is, groups with simple reduced group C-algebras.In joint work with Matthew Kennedy......, we consider reduced twisted crossed products overC-simple groups. For any twisted C-dynamical system over a C-simple group, we provethat there is a one-to-one correspondence between maximal invariant ideals in the underlyingC-algebra and maximal ideals in the reduced crossed product. When......*-algebras, and relate the intersection property for group actions on unital C*-algebras to the intersection property for theequivariant injective envelope. Moreover, we also prove that the equivariant injective envelopeof the centre of the injective envelope of a unital C*-algebra can be regarded as a C...

  17. Pellet injection requirements for TORE SUPRA

    International Nuclear Information System (INIS)

    Lafferranderie, J.

    1986-01-01

    The main parameters of TORE SUPRA are outlined and pellet injection requirements to meet plasma density goals are discussed. Topics considered include plasma buildup, plasma refueling and penetration depth

  18. Modified and reverse radiometric flow injection analysis

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Ba, H; Khin, M M; Aung, K; Thida, [Yangon Univ. (Myanmar). Dept. of Chemistry; Toelgyessy, J [Slovak Technical Univ., Bratislava (Slovakia). Dept. of Environmental Science

    1994-06-01

    Determination of [sup 137]Cs and [sup 60]Co by using modified and reverse radiometric flow injection analysis is described. Two component RFIA was also realized using [sup 60]Co and [sup 137]Cs radionuclides. (author) 2 refs.; 5 figs.

  19. AA injection kicker in its tank

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    For single-turn injection of the antiprotons, a septum at the end of the injection line made the beam parallel to the injection orbit, and a quarter of a betatron-wavelength downstream a fast kicker corrected the angle. Kicker type: lumped delay line. PFN voltage 56 kV. Bending angle 7.5 mrad; kick-strength 0.9 Tm; fall-time 95%-5% in 150 ns. The injection orbit is to the left, the stack orbit to the far right. A fast shutter near the central orbit had to be closed before the kicker fired, so as to protect the stack core from being shaken by the kicker's fringe field. The shutter is shown in closed position.

  20. Antiproton Production beam and Reverse Injection System

    Energy Technology Data Exchange (ETDEWEB)

    Chadwick, G.

    1981-08-16

    The objectives of this project are two fold: (1) To extract high energy protons from the Main Ring (MR) and target them to produce antiprotons which are subsequently captured in the existing Booster accelerator; and (2) to provide a channel for injecting either protons or antiprotons into the MR from the booster in a direction opposite to that of the normal proton acceleration as colliding beams can be created. The present design, therefore, is in support of two separate larger projects, viz., the collisions of protons in the Tevatron (normal circulation direction) with 'reverse injected' protons in the MR, and the collision of normal direction protons with reverse injected antiprotons either in the MR or in the Tevatron. Figure 1 shows the layout of the project area. It spans the shortest distance between possible injection/ejection points in the existing accelerator structures, hence minimizing costs. The tunnel will lie underground at the level of the MR and booster.

  1. LHC injection optics measurements at commissioning (2015)

    CERN Document Server

    Garcia-Tabares Valdivieso, Ana; Coello De Portugal - Martinez Vazquez, Jaime Maria; Garcia-Bonilla, Alba-Carolina; Langner, Andy Sven; Maclean, Ewen Hamish; Malina, Lukas; Mcateer, Meghan Jill; Persson, Tobias Hakan Bjorn; Skowronski, Piotr Krzysztof; Tomas Garcia, Rogelio; CERN. Geneva. ATS Department

    2016-01-01

    This report describes the measurement and correction process followed during the 2015 LHC injection optics commissioning which extended into Machine Developments (MDs). Results have been analyzed and compared to the 2012 measurements.

  2. Performance of the ALS injection system

    International Nuclear Information System (INIS)

    Kim, C.H.

    1993-05-01

    The authors started commissioning the Advanced Light Source (ALS) storage ring on January 11, 1993. The stored beam reached 60 mA on March 24, 1993 and 407 mA on April 9, 1993. The fast pace of storage ring commissioning can be attributed partially to the robust injection system. In this paper they describe the operating characteristics of the ALS injection system

  3. Frequency of booster injections of allergoids.

    Science.gov (United States)

    Norman, P S; Creticos, P S; Marsh, D G

    1990-01-01

    In 1982, 43 ragweed-sensitive patients receiving maintenance injections of full doses of ragweed allergoid were selected for a study of the immunologic and clinical efficacy of booster injections only four times a year. These patients had participated for 2 to 7 years as part of a trial of mixes of up to four allergoids to common pollens in the mid-Atlantic area tailored to each patient's skin test sensitivity. They were divided into a group (21 patients) to receive injections every 3 months and a group (22 patients) to receive injections about every 6 weeks (eight injections per year). Patients were rerandomized after 1 year so that half of each original group switched to the alternate treatment, and this program was continued until after the ragweed season of 1985. Thirty-four patients were still under study the last year. Doses, per injection, were 100 allergoid units (1 allergoid unit equals 100 PNU) of each allergen in the mixture. Symptom scores during the 8 weeks of each of the four ragweed seasons were not significantly higher in the 3-month treated group. IgG antibody levels to Amb a I (antigen E) were followed until early 1984 and were not significantly different in the two groups, even though the 6-week treated patients received a two times higher cumulative dose per year. Rates of local and systemic reactions (percent of injections eliciting reactions) were not different in the groups, which means that the 3-month treated group had about half as many reactions by virtue of taking half as many injections.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Application of EMILAC to pellet injection

    International Nuclear Information System (INIS)

    Iwamura, Yasuhiro; Yamasaki, Takao; Nakamura, Hirone; Hashimoto, Mitsuo; Miya, Kenzo

    1987-01-01

    A new type of electromagnetic accelerator for pellet injection is proposed. Projectile of cylinder shape is accelerated with the repulsive force generated by a combination of two coils, which are different in purpose. And the accelerator is named EMILAC (Electro-Magnetic Inductive Linear Accelerator). In this paper, we investigate the method of applying EMILAC to pellet injection, and calculate the ablation rate of pellet. (author)

  5. Rapid colorimetric assay for gentamicin injection.

    Science.gov (United States)

    Tarbutton, P

    1987-01-01

    A rapid colorimetric method for determining gentamicin concentration in commercial preparations of gentamicin sulfate injection was developed. Methods currently available for measuring gentamicin concentration via its colored complex with cupric ions in alkaline solution were modified to reduce the time required for a single analysis. The alkaline copper tartrate (ACT) reagent solution was prepared such that each milliliter contained 100 mumol cupric sulfate, 210 mumol potassium sodium tartrate, and 1.25 mmol sodium hydroxide. The assay involves mixing 0.3 mL gentamicin sulfate injection 40 mg/mL (of gentamicin), 1.0 mL ACT reagent, and 0.7 mL water; the absorbance of the resulting solution at 560 nm was used to calculate the gentamicin concentration in the sample. For injections containing 10 mg/mL of gentamicin, the amount of the injection was increased to 0.5 mL and water decreased to 0.5 mL. The concentration of gentamicin in samples representing 11 lots of gentamicin sulfate injection 40 mg/mL and 8 lots of gentamicin sulfate injection 10 mg/mL was determined. The specificity, reproducibility, and accuracy of the assay were assessed. The colored complex was stable for at least two hours. Gentamicin concentration ranged from 93.7 to 108% and from 95 to 109% of the stated label value of the 40 mg/mL and the 10 mg/mL injections, respectively. No components of the preservative system present in the injections interfered with the assay. Since other aminoglycosides produced a colored complex, the assay is not specific for gentamicin. The assay was accurate and reproducible over the range of 4-20 mg of gentamicin. This rapid and accurate assay can be easily applied in the hospital pharmacy setting.

  6. Menangkal Serangan SQL Injection Dengan Parameterized Query

    Directory of Open Access Journals (Sweden)

    Yulianingsih Yulianingsih

    2016-06-01

    Full Text Available Semakin meningkat pertumbuhan layanan informasi maka semakin tinggi pula tingkat kerentanan keamanan dari suatu sumber informasi. Melalui tulisan ini disajikan penelitian yang dilakukan secara eksperimen yang membahas tentang kejahatan penyerangan database secara SQL Injection. Penyerangan dilakukan melalui halaman autentikasi dikarenakan halaman ini merupakan pintu pertama akses yang seharusnya memiliki pertahanan yang cukup. Kemudian dilakukan eksperimen terhadap metode Parameterized Query untuk mendapatkan solusi terhadap permasalahan tersebut.   Kata kunci— Layanan Informasi, Serangan, eksperimen, SQL Injection, Parameterized Query.

  7. Dimethyl Ether in Diesel Fuel Injection Systems

    DEFF Research Database (Denmark)

    Sorenson, Spencer C.; Glensvig, M.; Abata, D. L.

    1998-01-01

    A study of the behaviour of DME in diesel injection systems. A discussion of the effects of compressibility of DME on compression work and wave propagation.DME spray shapes and penetration rates......A study of the behaviour of DME in diesel injection systems. A discussion of the effects of compressibility of DME on compression work and wave propagation.DME spray shapes and penetration rates...

  8. TFTR neutral beam injection system conceptual design

    International Nuclear Information System (INIS)

    1975-01-01

    Three subsystems are described in the following chapters: (1) Neutral Beam Injection Line; (2) Power Supplies; and (3) Controls. Each chapter contains two sections: (1) Functions and Design Requirements; this is a brief listing of the requirements of components of the subsystem. (2) Design Description; this section describes the design and cost estimates. The overall performance requirements of the neutral beam injection system are summarized. (MOW)

  9. Electron injection in semiconductor drift detectors

    International Nuclear Information System (INIS)

    Rehak, P.; Gatti, E.; Longoni, A.; Sampietro, M.; Castoldi, A.; Vacchi, A.

    1990-01-01

    The paper reports the first successful results of a simple MOS structure to inject electrons at a given position in Silicon Drift Detectors. The structure allows on-line calibration of the drift velocity of electrons within the detector. The calibration is a practical method to trace the temperature dependence of the electron mobility. Several of these injection structures can be implemented in silicon drift detectors without additional steps in the fabrication process. 5 refs., 11 figs

  10. The new injection beamline at VERA

    International Nuclear Information System (INIS)

    Priller, Alfred; Melber, Karl; Forstner, Oliver; Golser, Robin; Kutschera, Walter; Steier, Peter; Wallner, Anton

    2010-01-01

    VERA has been operated for 12 years with one 40-cathode SNICS ion source. Since the number of isotopes investigated at VERA increased steadily, we decided to install a second ion source. Due to space restrictions, a new injection line had to be built and merged into the existing one. The major task was to build an electrostatic analyzer assembly to accommodate injection from two ion sources.

  11. Epidural steroid injection for lumbosacral radiculopathy

    International Nuclear Information System (INIS)

    Sung, Mi Sook

    2006-01-01

    Low back pain combined with radicular pain remains as one of the most challenging musculoskeletal problems for its therapeutic management. This malady results from nerve root impingement and/or inflammation that causes neurologic symptoms in the distribution of the affected nerve root(s) Conservative treatment, percutaneous spine interventions and surgery have all been used as treatment; and the particular treatment that's chosen depends on the severity of the clinical and neurologic presentation. In 1930, Evans reported that sciatica could treated by epidural injection. The use of epidural corticosteroid injections for the treatment of axial and radicular back pain was first reported in 1953. Epidural steroid injections are currently used by many medical professionals for the treatment of lumbosacral radiculopathy. Performing 'blind' epidural steroid injection lacks target specificity that often results in incorrect delivery of medication to the lesion. Imaging-guided steroid injections are now becoming more popular despite the controversy regarding their efficacy. Many reports, including a few randomized controlled trials, have documented the clinical utility of epidural steroid injections

  12. Epidural steroid injection for lumbosacral radiculopathy

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Mi Sook [The Catholic University of Korea, Pucheon (Korea, Republic of)

    2006-06-15

    Low back pain combined with radicular pain remains as one of the most challenging musculoskeletal problems for its therapeutic management. This malady results from nerve root impingement and/or inflammation that causes neurologic symptoms in the distribution of the affected nerve root(s) Conservative treatment, percutaneous spine interventions and surgery have all been used as treatment; and the particular treatment that's chosen depends on the severity of the clinical and neurologic presentation. In 1930, Evans reported that sciatica could treated by epidural injection. The use of epidural corticosteroid injections for the treatment of axial and radicular back pain was first reported in 1953. Epidural steroid injections are currently used by many medical professionals for the treatment of lumbosacral radiculopathy. Performing 'blind' epidural steroid injection lacks target specificity that often results in incorrect delivery of medication to the lesion. Imaging-guided steroid injections are now becoming more popular despite the controversy regarding their efficacy. Many reports, including a few randomized controlled trials, have documented the clinical utility of epidural steroid injections.

  13. Magnetic detection of ferrofluid injection zones

    Energy Technology Data Exchange (ETDEWEB)

    Borglin, S.; Moridis, G.; Becker, A.

    1998-03-01

    Ferrofluids are stable colloidal suspensions of magnetic particles that can be stabilized in various carrier liquids. In this study the authors investigate the potential of ferrofluids to trace the movement and position of liquids injected in the subsurface using geophysical methods. An ability to track and monitor the movement and position of injected liquids is essential in assessing the effectiveness of the delivery system and the success of the process. Ferrofluids can also provide a significant detection and verification tool in containment technologies, where they can be injected with the barrier liquids to provide a strong signature allowing determination of the barrier geometry, extent, continuity and integrity. Finally, ferrofluids may have unique properties as tracers for detecting preferential flow features (such as fractures) in the subsurface, and thus allow the design of more effective remediation systems. In this report the authors review the results of the investigation of the potential of ferrofluids to trace the movement and position of liquids injected in the subsurface using geophysical methods. They demonstrate the feasibility of using conventional magnetometry for detecting subsurface zones of injected ferrofluids used to trace liquids injected for remediation or barrier formation. The geometrical shapes considered were a sphere, a thin disk, a rectangular horizontal slab, and a cylinder. Simple calculations based on the principles of magnetometry are made to determine the detection depths of FTs. Experiments involving spherical, cylindrical and horizontal slabs show a very good agreement between predictions and measurements.

  14. High power neutral beam injection in LHD

    International Nuclear Information System (INIS)

    Tsumori, K.; Takeiri, Y.; Nagaoka, K.

    2005-01-01

    The results of high power injection with a neutral beam injection (NBI) system for the large helical device (LHD) are reported. The system consists of three beam-lines, and two hydrogen negative ion (H - ion) sources are installed in each beam-line. In order to improve the injection power, the new beam accelerator with multi-slot grounded grid (MSGG) has been developed and applied to one of the beam-lines. Using the accelerator, the maximum powers of 5.7 MW were achieved in 2003 and 2004, and the energy of 189 keV reached at maximum. The power and energy exceeded the design values of the individual beam-line for LHD. The other beam-lines also increased their injection power up to about 4 MW, and the total injection power of 13.1 MW was achieved with three beam-lines in 2003. Although the accelerator had an advantage in high power beam injection, it involved a demerit in the beam focal condition. The disadvantage was resolved by modifying the aperture shapes of the steering grid. (author)

  15. Dual fuel injection piggyback controller system

    Science.gov (United States)

    Muji, Siti Zarina Mohd.; Hassanal, Muhammad Amirul Hafeez; Lee, Chua King; Fawzi, Mas; Zulkifli, Fathul Hakim

    2017-09-01

    Dual-fuel injection is an effort to reduce the dependency on diesel and gasoline fuel. Generally, there are two approaches to implement the dual-fuel injection in car system. The first approach is changing the whole injector of the car engine, the consequence is excessive high cost. Alternatively, it also can be achieved by manipulating the system's control signal especially the Electronic Control Unit (ECU) signal. Hence, the study focuses to develop a dual injection timing controller system that likely adopted to control injection time and quantity of compressed natural gas (CNG) and diesel fuel. In this system, Raspberry Pi 3 reacts as main controller unit to receive ECU signal, analyze it and then manipulate its duty cycle to be fed into the Electronic Driver Unit (EDU). The manipulation has changed the duty cycle to two pulses instead of single pulse. A particular pulse mainly used to control injection of diesel fuel and another pulse controls injection of Compressed Natural Gas (CNG). The test indicated promising results that the system can be implemented in the car as piggyback system. This article, which was originally published online on 14 September 2017, contained an error in the acknowledgment section. The corrected acknowledgment appears in the Corrigendum attached to the pdf.

  16. Digital Twin concept for smart injection molding

    Science.gov (United States)

    Liau, Y.; Lee, H.; Ryu, K.

    2018-03-01

    Injection molding industry has evolved over decades and became the most common method to manufacture plastic parts. Monitoring and improvement in the injection molding industry are usually performed separately in each stage, i.e. mold design, mold making and injection molding process. However, in order to make a breakthrough and survive in the industrial revolution, all the stages in injection molding need to be linked and communicated with each other. Any changes in one stage will cause a certain effect in other stage because there is a correlation between each other. Hence, the simulation should not only based on the input of historical data, but it also needs to include the current condition of equipment and prediction of future events in other stages to make the responsive decision. This can be achieved by implementing the concept of Digital Twin that models the entire process as a virtual model and enables bidirectional control with the physical process. This paper presented types of data and technology required to build the Digital Twin for the injection molding industry. The concept includes Digital Twin of each stage and integration of these Digital Twin model as a thoroughgoing model of the injection molding industry.

  17. Injection and accumulation method in the TARN

    International Nuclear Information System (INIS)

    Yamada, S.; Katayama, T.

    1979-03-01

    The test accumulation ring for NUMATRON (TARN) is being constructed at INS, University of Tokyo. The main purpose of the TARN is to establish some techniques related to beam injection and RF stacking, ultrahigh vacuum, and beam monitoring and handling. In this paper, the injection and accumulation methods in the TARN are described. The combination of multiturn injection and RF stacking is applied to the TARN. Heavy ions from the INS sector focusing (SF) cyclotron are injection through a magnetic and an electrostatic inflectors. Two pulse magnets and a bump field excited by square wave current are used for the multiturn injection method. The procedure of the RF stacking is as follows. The beam from the cyclotron is transported to the ring, and is injected by a multiturn method. Then, the RF accelerating voltage is put on, and the beam is captured in the stable region of the RF acceleration. The RF voltage and the frequency are adiabatically changed, and the beam is moved to the stacking orbit. The RF voltage is put off, and the beam remains on the stacking orbit. In the present system, a repetitive stacking scheme is applied for the RF stacking. The momentum spread after the RF stacking is approximately proportional to the stacking number in synchrotron phase space. The stacking number is chosen so that the total aperture required for the combined method may not exceed the available aperture in the ring doughnut. (Kato, T.)

  18. Detecting modularity "smells" in dependencies injected with Java annotations

    NARCIS (Netherlands)

    Roubtsov, S.; Serebrenik, A.; Brand, van den M.G.J.

    2010-01-01

    Dependency injection is a recent programming mechanism reducing dependencies among components by delegating them to an external entity, called a dependency injection framework. An increasingly popular approach to dependency injection implementation relies upon using Java annotations, a special form

  19. Injection safety practices in a main referral hospital in northeastern ...

    African Journals Online (AJOL)

    2013-03-25

    Mar 25, 2013 ... containers specific for non-sharps infectious waste and 17 (77.3%) of the observed therapeutic injections ..... injection safety, a high percentage was not complying .... the availability of loose disposable injection equipment.

  20. Spin Injection from Ferromagnetic Metal Directly into Non-Magnetic Semiconductor under Different Injection Currents

    International Nuclear Information System (INIS)

    Ning, Deng; Lei, Zhang; Shu-Chao, Zhang; Pei-Yi, Chen; Jian-Shi, Tang

    2010-01-01

    For ferromagnetic metal (FM)/semiconductor (SC) structure with ohmic contact, the effect of carrier polarization in the semiconductor combined with drift part of injection current on current polarization is investigated. Based on the general model we established here, spin injection efficiency under different injection current levels is calculated. Under a reasonable high injection current, current polarization in the semiconductor is actually much larger than that predicted by the conductivity mismatch model because the effect of carrier polarization is enhanced by the increasing drift current. An appreciable current polarization of 1% could be achieved for the FM/SC structure via ohmic contact, which means that efficient spin injection from FM into SC via ohmic contact is possible. The reported dependence of current polarization on temperature is verified quantitatively. To achieve even larger spin injection efficiency, a gradient doping semiconductor is suggested to enhance the drift current effect

  1. Transient CFD studies on multiple jets issuing from injection tube

    International Nuclear Information System (INIS)

    Kumawat, Ganesh Lal; Kansal, Anuj Kumar; Maheshwari, Naresh Kumar; Rama Rao, A.

    2016-01-01

    Shut down system 2 of Advanced Heavy Water reactor incorporates the injection of liquid poison into moderator through injection tubes. The injection tubes consist of several holes distributed axially and circumferentially. Investigation of the poison jet progression and spreading from the holes of injection tube is important aspect of determining negative reactivity injection rate. This paper presents the CFD simulation to investigate poison jet progression and its spreading from the holes of injection tube. (author)

  2. Effects of injection angles on combustion processes using multiple injection strategies in an HSDI diesel engine

    Energy Technology Data Exchange (ETDEWEB)

    Tiegang Fang; Robert E. Coverdill; Chia-fon F. Lee; Robert A. White [North Carolina State University, Raleigh, NC (United States). Department of Mechanical and Aerospace Engineering

    2008-11-15

    Effects of injection angles and injection pressure on the combustion processes employing multiple injection strategies in a high-speed direct-injection (HSDI) diesel engine are presented in this work. Whole-cycle combustion and liquid spray evolution processes were visualized using a high-speed video camera. NOx emissions were measured in the exhaust pipe. Different heat release patterns are seen for two different injectors with a 70-degree tip and a 150-degree tip. No evidence of fuel-wall impingement is found for the first injection of the 150-degree tip, but for the 70-degree tip, some fuel impinges on the bowl wall and a fuel film is formed. For the second injection, a large amount of fuel deposition is observed for the 70-degree tip. Weak flame is seen for the first injection of the 150-degree tip while two sorts of flames are seen for the first injection of the 70-degree tip including an early weak flame and a late luminous film combustion flame. Ignition occurs near the spray tip in the vicinity of the bowl wall for the second injection events of the 150-degree tip, however, it is near the injector tip in the central region of the bowl for the 70-degree tip. The flame is more homogeneous for the 150-degree tip with higher injection pressure with little soot formation similar to a premixed-charge-compression-ignition (PCCI) combustion. For other cases, liquid fuel is injected into flames showing diffusion flame combustion. More soot luminosity is seen for the 70-degree tip due to significant fuel film deposition on the piston wall with fuel film combustion for both injection events. Lower NOx emissions were obtained for the narrow-angle injector due to the rich air-fuel mixture near the bowl wall during the combustion process. 30 refs., 11 figs., 3 tabs.

  3. INJECTING EQUPMENT SHARING AND PERCEPTION OF HIV AND HEPATITIS RISK AMONG INJECTING DRUG USERS IN BUDAPEST

    Science.gov (United States)

    Gyarmathy, V. Anna; Neaigus, Alan; Ujhelyi, Eszter

    2008-01-01

    In Central European states, rates of HIV among IDUs have been low although HCV infection is widespread. The goal of our study was to assess HIV infection, risk perceptions and injecting equipment sharing among injection drug users in Budapest, Hungary. Altogether 150 IDUs were interviewed (121 structured between 1999-2000 and 29 ethnographic between 2003-2004). The majority of them injected heroin (52% and 79%) and many injected amphetamines (51% and 35%). One person tested positive for HIV. Two thirds (68% of 121) shared injecting equipment (syringes, cookers and filters). Some participants said they shared syringes because they were not carrying them for fear of police harassment, and that they reused filters as a backup drug supply. In multivariate analysis, sharing of injecting equipment was associated with higher perceived susceptibility to HIV/AIDS, lower self-efficacy for sterile equipment use, higher motivation to comply with peer pressure to use dirty injecting equipment, and with having a criminal record. The high levels of injecting risk behaviors found in this study are a cause for serious concern. HIV prevention interventions need to address not only sharing syringes but also sharing and reusing other injecting equipment and drug filters. PMID:17129858

  4. Anesthetic efficacy of a repeated intraosseous injection following a primary intraosseous injection.

    Science.gov (United States)

    Jensen, Joanne; Nusstein, John; Drum, Melissa; Reader, Al; Beck, Mike

    2008-02-01

    The purpose of this prospective, randomized, single-blinded study was to determine the anesthetic efficacy of a repeated intraosseous injection given 30 minutes after a primary intraosseous injection. Using a crossover design, 55 subjects randomly received a primary X-tip intraosseous injection (Dentsply Inc, York, PA) of 1.4 mL of 2% lidocaine with epinephrine (using the Wand; Milestone Scientific, Deerfield, IL) and a repeated intraosseous or mock injection at 30 minutes in two appointments. The first molar and adjacent teeth were pulp tested every 2 minutes for a total of 120 minutes. Success was defined as obtaining two consecutive 80 readings with the electric pulp tester. Success of the initial intraosseous injection was 100% for the first molar. The repeated intraosseous injection mimicked the initial intraosseous injection in terms of pulpal anesthesia and statistically provided another 15 minutes of pulpal anesthesia. In conclusion, using the methodology presented, repeating the intraosseous injection 30 minutes after an initial intraosseous injection will provide an additional 15 minutes of pulpal anesthesia.

  5. Ultrasound-guided botulinum toxin injections

    Directory of Open Access Journals (Sweden)

    S. E. Khatkova

    2016-01-01

    Full Text Available One of the key conditions for achieving the desirable result during botulinum toxin therapy for muscular dystonia, spasticity, and other diseases accompanied by spasm, pain, and autonomic dysfunction (dystonias, spasticity, etc. is the proper administration of the agent into the muscles directly involved in the pathological process. The exact entry of botulinum toxin into the target muscles is essential for successful and safe treatment because its injection into a normal muscle may cause side effects. The most common errors are the incorrect depth and incorrect direction of a needle on insertion. Therefore, the exact injection of the agent particularly into the shallow and deep muscles is a difficult task even for an experienced specialist and requires the use of controlling methods.The European Consensus on Botulinum Toxin Therapy points out that various injection techniques are needed for the better identification of necessary muscles. However, there are currently no reports on the clear advantage of any technique. In our country, injections using palpation and anatomical landmarks have been widely used in routine practice so far; electromyographic monitoring and electrostimulation have been less frequently applied. In recent years, the new method ultrasound-guided injection has continued to grow more popular. This effective, accessible, and easy-to-use method makes it possible to manage a real-time injection process and to ensure the exact entry of the agent into the muscle. This paper is dedicated to a comparative analysis of different injection methods and to a description of the ultrasound-guided technique and its advantages over others. 

  6. Oil injection into the blast furnace

    Energy Technology Data Exchange (ETDEWEB)

    Dongsheng Liao; Mannila, P.; Haerkki, J.

    1997-12-31

    Fuel injection techniques have been extensively used in the commercial blast furnaces, a number of publications concerning the fuels injection have been reported. This present report only summarizes the study achievements of oil injection due to the research need the of authors, it includes the following parts: First, the background and the reasons reducing coke rate of oil injection are analyzed. Reducing coke rate and decreasing the ironmaking costs are the main deriving forces, the contents of C, H and ash are direct reasons reducing coke rate. It was also found that oil injection had great effects on the state of blast furnace, it made operation stable, center gas flow develop fully, pressure drop increase, descent speed of burden materials decrease and generation of thermal stagnation phenomena, the quality of iron was improved. Based on these effects, as an ideal mean, oil injection was often used to adjust the state of blast furnace. Secondly, combustion behavior of oil in the raceway and tuyere are discussed. The distribution of gas content was greatly changed, the location of CO, H{sub 2} generation was near the tuyere; the temperature peak shifts from near the raceway boundary to the tuyere. Oxygen concentration and blast velocity were two important factors, it was found that increasing excess oxygen ratio 0.9 to 1.3, the combustion time of oil decreases 0.5 msec, an increase of the blast velocity results in increasing the flame length. In addition, the nozzle position and oil rate had large effects on the combustion of oil. Based on these results, the limit of oil injection is also discussed, soot formation is the main reason limiting to further increase oil injection rate, it was viewed that there were three types of soot which were generated under blast furnace operating conditions. The reason generating soot is the incomplete conversion of the fuel. Finally, three methods improving combustion of oil in the raceway are given: Improvement of oil

  7. Persulfate injection into a gasoline source zone.

    Science.gov (United States)

    Sra, Kanwartej S; Thomson, Neil R; Barker, Jim F

    2013-07-01

    One pore volume of unactivated sodium persulfate was delivered into an emplaced gasoline residual source zone at CFB Borden. Concentrations of inorganic species (S2O8(2-), SO4(2-), Na(+), dissolved inorganic carbon (DIC)) and selected gasoline compounds (benzene, toluene, ethylbenzene, xylenes, trimethylbenzenes and naphthalene) were monitored across a transect equipped with 90 multilevel sampling points for >10months post-injection. Mass loading (M˙) of compounds constructed from the transect data was used for assessment purposes. Breakthrough of inorganic species was observed when the injection slug crossed the monitoring transect. An increase in [Formula: see text] indicated persulfate consumption during oxidation of gasoline compounds or degradation due to the interaction with aquifer materials. M˙DIC increased by >100% suggesting some mineralization of gasoline compounds during treatment. Mass loading for all the monitored gasoline compounds reduced by 46 to 86% as the inorganic slug crossed the monitoring transect. The cumulative mass discharge across the monitoring transect was 19 to 58% lower than that expected without persulfate injection. After the inorganic injection slug was flushed from the source zone a partial rebound (40 to 80% of baseline levels) of mass discharge of the monitored gasoline compounds was observed. The ensemble of data collected provides insight into the fate and transport of the injected persulfate solution, and the accompanying treatment of a gasoline the source zone. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Interface state generation after hole injection

    International Nuclear Information System (INIS)

    Zhao, C. Z.; Zhang, J. F.; Groeseneken, G.; Degraeve, R.; Ellis, J. N.; Beech, C. D.

    2001-01-01

    After terminating electrical stresses, the generation of interface states can continue. Our previous work in this area indicates that the interface state generation following hole injection originates from a defect. These defects are inactive in a fresh device, but can be excited by hole injection and then converted into interface states under a positive gate bias after hole injection. There is little information available on these defects. This article investigates how they are formed and attempts to explain why they are sensitive to processing conditions. Roles played by hydrogen and trapped holes will be clarified. A detailed comparison between the interface state generation after hole injection in air and that in forming gas is carried out. Our results show that there are two independent processes for the generation: one is caused by H 2 cracking and the other is not. The rate limiting process for the interface state generation after hole injection is discussed and the relation between the defects responsible for this generation and hole traps is explored. [copyright] 2001 American Institute of Physics

  9. Diagnosing the PEP-II Injection System

    Energy Technology Data Exchange (ETDEWEB)

    Decker, F.-J.; Donald, M.H.; Iverson, R.H.; Kulikov, A.; Pappas, G.C.; Weaver, M.; /SLAC

    2005-05-09

    The injection of beam into the PEP-II B-Factory, especially into the High Energy Ring (HER) has some challenges. A high background level in the BaBar detector has for a while inhibited us from trickling charge into the HER similar to the Low Energy Ring (LER). Analyzing the injection system has revealed many issues which could be improved. The injection bump between two kickers was not closed, mainly because the phase advance wasn't exactly 180{sup o} and the two kicker strengths were not balanced. Additionally we found reflections which kick the stored beam after the main kick and cause the average luminosity to drop about 3% for a 10 Hz injection rate. The strength of the overall kick is nearly twice as high as the design, indicating a much bigger effective septum thickness. Compared with single beam the background is worse when the HER beam is colliding with the LER beam. This hints that the beam-beam force and the observed vertical blow-up in the HER pushes the beam and especially the injected beam further out to the edge of the dynamic aperture or beyond.

  10. Diagnosing the PEP-II Injection System

    International Nuclear Information System (INIS)

    Decker, F.-J.; Donald, M.H.; Iverson, R.H.; Kulikov, A.; Pappas, G.C.; Weaver, M.; SLAC

    2005-01-01

    The injection of beam into the PEP-II B-Factory, especially into the High Energy Ring (HER) has some challenges. A high background level in the BaBar detector has for a while inhibited us from trickling charge into the HER similar to the Low Energy Ring (LER). Analyzing the injection system has revealed many issues which could be improved. The injection bump between two kickers was not closed, mainly because the phase advance wasn't exactly 180 o and the two kicker strengths were not balanced. Additionally we found reflections which kick the stored beam after the main kick and cause the average luminosity to drop about 3% for a 10 Hz injection rate. The strength of the overall kick is nearly twice as high as the design, indicating a much bigger effective septum thickness. Compared with single beam the background is worse when the HER beam is colliding with the LER beam. This hints that the beam-beam force and the observed vertical blow-up in the HER pushes the beam and especially the injected beam further out to the edge of the dynamic aperture or beyond

  11. Hot carrier injection degradation under dynamic stress

    International Nuclear Information System (INIS)

    Ma Xiao-Hua; Cao Yan-Rong; Hao Yue; Zhang Yue

    2011-01-01

    In this paper, we have studied hot carrier injection (HCI) under alternant stress. Under different stress modes, different degradations are obtained from the experiment results. The different alternate stresses can reduce or enhance the HC effect, which mainly depends on the latter condition of the stress cycle. In the stress mode A (DC stress with electron injection), the degradation keeps increasing. In the stress modes B (DC stress and then stress with the smallest gate injection) and C (DC stress and then stress with hole injection under V g = 0 V and V d = 1.8 V), recovery appears in the second stress period. And in the stress mode D (DC stress and then stress with hole injection under V g = −1.8 V and V d = 1.8 V), as the traps filled in by holes can be smaller or greater than the generated interface states, the continued degradation or recovery in different stress periods can be obtained. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  12. Persulfate injection into a gasoline source zone

    Science.gov (United States)

    Sra, Kanwartej S.; Thomson, Neil R.; Barker, Jim F.

    2013-07-01

    One pore volume of unactivated sodium persulfate was delivered into an emplaced gasoline residual source zone at CFB Borden. Concentrations of inorganic species (S2O82 -, SO42 -, Na+, dissolved inorganic carbon (DIC)) and selected gasoline compounds (benzene, toluene, ethylbenzene, xylenes, trimethylbenzenes and naphthalene) were monitored across a transect equipped with 90 multilevel sampling points for > 10 months post-injection. Mass loading (M˙) of compounds constructed from the transect data was used for assessment purposes. Breakthrough of inorganic species was observed when the injection slug crossed the monitoring transect. An increase in M indicated persulfate consumption during oxidation of gasoline compounds or degradation due to the interaction with aquifer materials. M increased by > 100% suggesting some mineralization of gasoline compounds during treatment. Mass loading for all the monitored gasoline compounds reduced by 46 to 86% as the inorganic slug crossed the monitoring transect. The cumulative mass discharge across the monitoring transect was 19 to 58% lower than that expected without persulfate injection. After the inorganic injection slug was flushed from the source zone a partial rebound (40 to 80% of baseline levels) of mass discharge of the monitored gasoline compounds was observed. The ensemble of data collected provides insight into the fate and transport of the injected persulfate solution, and the accompanying treatment of a gasoline the source zone.

  13. Water quality considerations resulting in the impaired injectivity of water injection and disposal wells

    International Nuclear Information System (INIS)

    Bennion, D.B.; Thomas, F.B.; Imer, D.; Ma, T.

    2000-01-01

    An environmentally responsible way to improve hydrocarbon recovery is to maintain pressure by water injection. This is a desirable method because unwanted produced water from oil and gas wells can be re-injected into producing or disposal formations. The success of the operation, however, depends on injecting the necessary volume of water economically, below the fracture gradient pressure of the formation. Well placement, geometry and inherent formation quality and relative permeability characteristics are some of the many other factors which influence the success of any injection project. Poor injection or poor quality of disposal water can also compromise the injectivity for even high quality sandstone or carbonate formations. This would necessitate costly workovers and recompletions. This paper presented some leading edge diagnostic techniques and evaluation methods to determine the quality of injected water. The same techniques could be used to better understand the effect of potential contaminants such as suspended solids, corrosion products, skim/carryover oil and grease, scales, precipitates, emulsions, oil wet hydrocarbon agglomerates and many other conditions which cause injectivity degradation. 14 refs., 1 tab., 15 figs

  14. Associations between injection risk and community disadvantage among suburban injection drug users in southwestern Connecticut, USA.

    Science.gov (United States)

    Heimer, Robert; Barbour, Russell; Palacios, Wilson R; Nichols, Lisa G; Grau, Lauretta E

    2014-03-01

    Increases in drug abuse, injection, and opioid overdoses in suburban communities led us to study injectors residing in suburban communities in southwestern Connecticut, US. We sought to understand the influence of residence on risk and injection-associated diseases. Injectors were recruited by respondent-driven sampling and interviewed about sociodemographics, somatic and mental health, injection risk, and interactions with healthcare, harm reduction, substance abuse treatment, and criminal justice systems. HIV, hepatitis B and C (HBV and HCV) serological testing was also conducted. Our sample was consistent in geographic distribution and age to the general population and to the patterns of heroin-associated overdose deaths in the suburban towns. High rates of interaction with drug abuse treatment and criminal justice systems contrasted with scant use of harm reduction services. The only factors associated with both dependent variables-residence in less disadvantaged census tracts and more injection risk-were younger age and injecting in one's own residence. This contrasts with the common association among urban injectors of injection-associated risk behaviors and residence in disadvantaged communities. Poor social support and moderate/severe depression were associated with risky injection practices (but not residence in specific classes of census tracts), suggesting that a region-wide dual diagnosis approach to the expansion of harm reduction services could be effective at reducing the negative consequences of injection drug use.

  15. Solid Organic Deposition During Gas Injection Studies

    DEFF Research Database (Denmark)

    Dandekar, Abhijit Y.; Andersen, Simon Ivar; Stenby, Erling Halfdan

    2000-01-01

    Recently a series of first contact miscibility (swelling) experiments have been performed on undersaturated light and heavy oils using LPG rich and methane rich injection gases, in which solid organic deposition was observed. A compositional gradient in the oils during the gas injection process....... The asphaltene content of the different oil samples were determined by the TP 143 method. The standard asphaltenes and the solid organic deposit recovered from the swelling tests were analyzed using FTIR, HPLC-SEC and H-1 NMR. The aim of these analyses is to reveal the molecular nature of the deposits formed...... during the gas injection process in comparison with the standard asphaltenes in order to understand the mechanisms involved in asphaltene deposition....

  16. Sub-stratum injection of fine tailings

    Energy Technology Data Exchange (ETDEWEB)

    Kesteren van, W.; Cornelisse, J.; Costello, M. [Deltares, Delft (Netherlands)

    2010-07-01

    This PowerPoint presentation discussed an experiment conducted to evaluate the sub-stratum injection of oil sands fine tailings. The hydraulic fracturing method was developed as a sub-surface dredging process for mining sand without removing the overburden. Pressure was used to transport the sand-water mixture, and the high pressures used in the process resulted in water losses through the clay-sand interface. The experiment was conducted with soft clay, compacted sand, and an injection feed. Results of the study showed that the injection method may be successful. However, further research is required to characterize the fracture energy of oil sands and the rheology of fine tailings. Horizontal hydraulic fracturing equations were presented. Tensile failures in clay and oil sands were discussed. Fractures were identified by deformation and discharge rates. Crack propagation methods were also studied. tabs., figs.

  17. Design of the ESCAR injection beam line

    International Nuclear Information System (INIS)

    Tanabe, J.; Staples, J.; Yourd, R.

    1975-01-01

    The design features of the elements of the ESCAR (Experimental Superconducting Accelerator Ring) injection beam line are described. The junction of the proton transport system with the ESCAR injection straight section requires the design of mechanical elements compatible with the 10 -11 torr vacuum requirements of the main ring. These elements include a novel septum magnet whose salient design features include a current-carrying septum of tapered thicknesses to reduce the overall power requirements and total enclosure of the magnet coil in a metal can for vacuum compatibility. Other elements are a wire electro-static septum and several fast-rise ''bump magnets''. A transition cryopump is designed to separate the main ring vacuum from the relatively poor 10 -6 torr vacuum of the conventional beam transport line. A brief description of the conventional beam transport line from the 50 MeV proton linac, recently installed for Bevatron injection,is also included. (U.S.)

  18. Spin injection into GaAs

    Energy Technology Data Exchange (ETDEWEB)

    Endres, Bernhard

    2013-11-01

    In this work spin injection into GaAs from Fe and (Ga,Mn)As was investigated. For the realization of any spintronic device the detailed knowledge about the spin lifetime, the spatial distribution of spin-polarized carriers and the influence of electric fields is essential. In the present work all these aspects have been analyzed by optical measurements of the polar magneto-optic Kerr effect (pMOKE) at the cleaved edge of the samples. Besides the attempt to observe spin pumping and thermal spin injection into n-GaAs the spin solar cell effect is demonstrated, a novel mechanism for the optical generation of spins in semiconductors with potential for future spintronic applications. Also important for spin-based devices as transistors is the presented realization of electrical spin injection into a two-dimensional electron gas.

  19. The history of injectable facial fillers.

    Science.gov (United States)

    Kontis, Theda C; Rivkin, Alexander

    2009-05-01

    In an attempt to maintain a youthful appearance or to reconstruct facial deformities, physicians have greeted new technologies with excitement. In the late 1800 s, shortly after the invention of the syringe, chemical agents were used for facial augmentation. Unfortunately, history has taught us that new technologies must be used with care, because complications can occur, sometimes many years after initial treatment. The first injectable filling agent was paraffin, whose use was abandoned after complications of migration, embolization, and granuloma formation were described. More recently, silicone use was banned by the U.S. Food and Drug Administration (FDA) because of similar complications. In 1981, bovine collagen was the first agent to be approved by the FDA for cosmetic injection. Since its approval, dozens of injectable filling agents have been developed, and many are already FDA approved for cosmetic use. This article will review the highlights of the evolution of facial filling agents.

  20. Large scale injection test (LASGIT) modelling

    International Nuclear Information System (INIS)

    Arnedo, D.; Olivella, S.; Alonso, E.E.

    2010-01-01

    Document available in extended abstract form only. With the objective of understanding the gas flow processes through clay barriers in schemes of radioactive waste disposal, the Lasgit in situ experiment was planned and is currently in progress. The modelling of the experiment will permit to better understand of the responses, to confirm hypothesis of mechanisms and processes and to learn in order to design future experiments. The experiment and modelling activities are included in the project FORGE (FP7). The in situ large scale injection test Lasgit is currently being performed at the Aespoe Hard Rock Laboratory by SKB and BGS. An schematic layout of the test is shown. The deposition hole follows the KBS3 scheme. A copper canister is installed in the axe of the deposition hole, surrounded by blocks of highly compacted MX-80 bentonite. A concrete plug is placed at the top of the buffer. A metallic lid anchored to the surrounding host rock is included in order to prevent vertical movements of the whole system during gas injection stages (high gas injection pressures are expected to be reached). Hydration of the buffer material is achieved by injecting water through filter mats, two placed at the rock walls and two at the interfaces between bentonite blocks. Water is also injected through the 12 canister filters. Gas injection stages are performed injecting gas to some of the canister injection filters. Since the water pressure and the stresses (swelling pressure development) will be high during gas injection, it is necessary to inject at high gas pressures. This implies mechanical couplings as gas penetrates after the gas entry pressure is achieved and may produce deformations which in turn lead to permeability increments. A 3D hydro-mechanical numerical model of the test using CODE-BRIGHT is presented. The domain considered for the modelling is shown. The materials considered in the simulation are the MX-80 bentonite blocks (cylinders and rings), the concrete plug

  1. Surface Microstructure Replication in Injection Moulding

    DEFF Research Database (Denmark)

    Hansen, Hans Nørgaard; Arlø, Uffe Rolf

    2005-01-01

    topography is transcribed onto the plastic part through complex mechanisms. This replication however, is not perfect, and the replication quality depends on the plastic material properties, the topography itself, and the process conditions. This paper describes and discusses an investigation of injection...... moulding of surface microstructures. Emphasis is put on the ability to replicate surface microstructures under normal injection moulding conditions, notably with low cost materials at low mould temperatures. The replication of surface microstructures in injection moulding has been explored...... for Polypropylene at low mould temperatures. The process conditions were varied over the recommended process window for the material. The geometry of the obtained structures was analyzed. Evidence suggests that step height replication quality depends linearly on structure width in a certain range. Further...

  2. Intraurethral Injection of Autologous Minced Skeletal Muscle

    DEFF Research Database (Denmark)

    Gräs, Søren; Klarskov, Niels; Lose, Gunnar

    2014-01-01

    noted. CONCLUSIONS: Intraurethral injection of minced autologous muscle tissue is a simple surgical procedure that appears safe and moderately effective in women with uncomplicated stress urinary incontinence. It compares well to a more complicated regenerative strategy using in vitro expanded muscle......PURPOSE: Intraurethral injection of in vitro expanded autologous skeletal muscle derived cells is a new regenerative therapy for stress urinary incontinence. We examined the efficacy and safety of a simpler alternative strategy using freshly harvested, minced autologous skeletal muscle tissue...... with its inherent content of regenerative cells. MATERIALS AND METHODS: A total of 20 and 15 women with uncomplicated and complicated stress urinary incontinence, respectively, received intraurethral injections of minced autologous skeletal muscle tissue and were followed for 1 year. Efficacy was assessed...

  3. Targeting the Plantar Fascia for Corticosteroid Injection.

    Science.gov (United States)

    Salvi, Andrea Emilio

    2015-01-01

    Plantar fasciitis is often a difficult condition to treat. It is related to repetitive strain of the fascia at its attachment to the heel bone. This condition quite often appears with the concomitant presence of a plantar calcaneal heel spur. Corticosteroid injection is a popular treatment choice for plantar fasciitis, and accurate localization of the injected medication is essential for successful resolution of symptoms after the injection. In the present brief technical communication, a method for targeting the attachment of the plantar fascia to the medial tubercle of the tuberosity of the calcaneus is described. The targeting method uses the lateral radiograph of the foot to aid in localization of the proximal attachment of the plantar fascia to the calcaneus. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Electrically Injected UV-Visible Nanowire Lasers

    Energy Technology Data Exchange (ETDEWEB)

    Wang, George T.; Li, Changyi; Li, Qiming; Liu, Sheng; Wright, Jeremy Benjamin; Brener, Igal; Luk, Ting -Shan; Chow, Weng W.; Leung, Benjamin; Figiel, Jeffrey J.; Koleske, Daniel D.; Lu, Tzu-Ming

    2015-09-01

    There is strong interest in minimizing the volume of lasers to enable ultracompact, low-power, coherent light sources. Nanowires represent an ideal candidate for such nanolasers as stand-alone optical cavities and gain media, and optically pumped nanowire lasing has been demonstrated in several semiconductor systems. Electrically injected nanowire lasers are needed to realize actual working devices but have been elusive due to limitations of current methods to address the requirement for nanowire device heterostructures with high material quality, controlled doping and geometry, low optical loss, and efficient carrier injection. In this project we proposed to demonstrate electrically injected single nanowire lasers emitting in the important UV to visible wavelengths. Our approach to simultaneously address these challenges is based on high quality III-nitride nanowire device heterostructures with precisely controlled geometries and strong gain and mode confinement to minimize lasing thresholds, enabled by a unique top-down nanowire fabrication technique.

  5. Commercial air travel after intraocular gas injection.

    Science.gov (United States)

    Houston, Stephen; Graf, Jürgen; Sharkey, James

    2012-08-01

    Passengers with intraocular gas are at risk of profound visual loss when exposed to reduced absolute pressure within the cabin of a typical commercial airliner. Information provided on the websites of the world's 10 largest airlines offer a considerable range of opinion as to when it might be safe to fly after gas injection. Physicians responsible for clearing pseassengers as 'fit to fly' should be aware modern retinal surgical techniques increasingly employ long-acting gases as vitreous substitutes. The kinetics of long-acting intraocular gases must be considered when deciding how long after surgery it is safe to travel. It is standard practice to advise passengers not to fly in aircraft until the gas is fully resorbed. To achieve this, it may be necessary to delay travel for approximately 2 wk after intraocular injection of sulfur hexafluoride (SF6) and for 6 wk after injection of perfluoropropane (C3F8).

  6. Cavity Pressure Behaviour in Micro Injection Moulding

    DEFF Research Database (Denmark)

    Griffiths, C.A.; Dimov, S.S.; Scholz, S.

    2010-01-01

    as well as with the filling of the cavity by the polymer melt. In this paper, two parameters derived from cavity pressure over time (i.e. pressure work). The influence of four µIM parameters (melt temperature, mould temperature, injection speed, aand packing pressure) on the two pressure-related outputs...... has been investigated by moulding a micro fluidic component on three different polymers (PP, ABS, PC) using the design of experiment approach. Similar trends such as the effects of a higher injection speed in decreasing the pressure work and of a lower temperature in decreasing pressure rate have been......Process monitoring of micro injection moulding (µIM) is of crusial importance to analyse the effect of different parameter settings on the process and to assess its quality. Quality factors related to cavity pressure can provide useful information directly connected with the dyanmics of the process...

  7. Sensorless Control of IPMSM by Voltage Injection

    DEFF Research Database (Denmark)

    Matzen, Torben N.; Bech, Michael Møller

    2006-01-01

    In this paper a sensorless discrete current control of an Interior Permanent Magnet Synchrouns Motor (IPMSM) by voltage injection is designed and tested. The whole controller is operating in the dq-frame and for this reason the rotor position is essential to know, to transform between the station......In this paper a sensorless discrete current control of an Interior Permanent Magnet Synchrouns Motor (IPMSM) by voltage injection is designed and tested. The whole controller is operating in the dq-frame and for this reason the rotor position is essential to know, to transform between...... the stationary frame and the rotor xed dq-frame. To obtain the position even at standstill a sensorless scheme using voltage injection is added to the current controller....

  8. A Cadaveric Study on Sacroiliac Joint Injection

    Science.gov (United States)

    Zou, Yu-Cong; Li, Yi-Kai; Yu, Cheng-Fu; Yang, Xian-Wen; Chen, Run-Qi

    2015-01-01

    The scope of this study was to explore the possibility as well as the feasibility of sacroiliac joint injection following simple X-ray clip location. For the cadaveric study, 10 fixed sacroiliac joint (SIJ) sectional specimens, 4 dried cadaveric pelvises and 21 embalmed adult cadaveric pelvises were dissected, followed by an injection of contrast agent into the joint. The irrigation of the agent was observed through CT scanning. For the radiologic study, 188 CT scans of ankylosing spondylitis patients (143 male, 45 female) were collected from 2010 to 2012, in Nanfang Hospital. What was measured was (1) Distance between the posterior midline and sagittal synovium; (2) Length of the sagittal synovium; (3) Distance between the midpoint of the sagittal synovium and posterior superior iliac spine; and (4) Distance between the superficial skin vertical to the sagittal synovium point were measured. For the practice-based study: 20 patients (17 males and 3 females) with early ankylosing spondylitis, from Nanfang Hospital affiliated with Southern Medical University were recruited, and sacroiliac joint unguided injections were done on the basis of the cadaveric and radiologic study. Only the inferior 1/3rd portion parallel to the posterior midline could be injected into since the superior 2/3rd portion were filled with interosseous ligaments. Thirteen of the 20 patients received successful injections as identified by CT scan using the contrast agent. Sacroiliac joint injection following simple X-ray clip location is possible and feasible if the operation is performed by trained physicians familiar with the sacroiliac joint and its surrounding anatomic structures. PMID:25692437

  9. Groundwater monitoring for deep-well injection

    International Nuclear Information System (INIS)

    Chia, Y.; Chiu, J.

    1994-01-01

    A groundwater monitoring system for detecting waste migration would not only enhance confidence in the long-term containment of injected waste, but would also provide early warnings of contamination for prompt responses to protect underground sources of drinking water (USDWs). Field experiences in Florida have demonstrated monitoring water quality and fluid pressure changes in overlying formations is useful in detecting the upward migration of injected waste. Analytical and numerical solutions indicate changes in these two monitoring parameters can vary on the basis of hydrogeologic characteristics, operation conditions, and the distances from the injection well to the monitoring wells and to the preferential hydrologic conduits. To detect waste migration through defects around the wellbore or the leaky containment interval, groundwater monitoring wells should be placed as close as possible to an injection well. In the vertical direction, a monitoring well completed in a permeable interbed within the containment interval is expected to have the highest potential for detecting upward migration. Another acceptable horizon for groundwater monitoring is the lower portion of the buffer brine aquifer immediately above the containment interval. Monitoring wells in USDWs may be needed when waste has been detected in deeper formations or when leakage out of well casings poses a concern. A monitoring well open to the injection interval is of little value in alleviating the concerns of long-term upward migration. Moreover, the installation of the well could create additional preferential pathways. Complications in groundwater monitoring may arise at existing injection sites, especially with prior releases. It is also important to recognize that monitoring in the vicinity of the wellbore may not be effective for detecting waste migration through unidentified unplugged wells or undetected transmissive fractures

  10. Viscous hydrophilic injection matrices for serial crystallography

    Directory of Open Access Journals (Sweden)

    Gabriela Kovácsová

    2017-07-01

    Full Text Available Serial (femtosecond crystallography at synchrotron and X-ray free-electron laser (XFEL sources distributes the absorbed radiation dose over all crystals used for data collection and therefore allows measurement of radiation damage prone systems, including the use of microcrystals for room-temperature measurements. Serial crystallography relies on fast and efficient exchange of crystals upon X-ray exposure, which can be achieved using a variety of methods, including various injection techniques. The latter vary significantly in their flow rates – gas dynamic virtual nozzle based injectors provide very thin fast-flowing jets, whereas high-viscosity extrusion injectors produce much thicker streams with flow rates two to three orders of magnitude lower. High-viscosity extrusion results in much lower sample consumption, as its sample delivery speed is commensurate both with typical XFEL repetition rates and with data acquisition rates at synchrotron sources. An obvious viscous injection medium is lipidic cubic phase (LCP as it is used for in meso membrane protein crystallization. However, LCP has limited compatibility with many crystallization conditions. While a few other viscous media have been described in the literature, there is an ongoing need to identify additional injection media for crystal embedding. Critical attributes are reliable injection properties and a broad chemical compatibility to accommodate samples as heterogeneous and sensitive as protein crystals. Here, the use of two novel hydrogels as viscous injection matrices is described, namely sodium carboxymethyl cellulose and the thermo-reversible block polymer Pluronic F-127. Both are compatible with various crystallization conditions and yield acceptable X-ray background. The stability and velocity of the extruded stream were also analysed and the dependence of the stream velocity on the flow rate was measured. In contrast with previously characterized injection media, both new

  11. Neutral beam injection on the PLT tokamak

    International Nuclear Information System (INIS)

    Schilling, G.; Ashcroft, D.L.; Eubank, H.P.; Grisham, L.R.; Knauer, R.C.; Stewart, L.D.; Stooksberry, R.W.; Ulrickson, M.; Williams, M.D.

    1981-01-01

    We describe the operation of the neutral beam injection system on the PLT tokamak. Improvements, retrofits, and conditioning have changed the injection system from an experiment in itself to a fairly reliable and useful plasma heating tool. We will present a brief overview of our physics achievements and then describe the system as it exists now. This will include injector performance, conditioning needs, maintenance needs, reliability, and daily operating sequences. We will also include hardware modifications and additions, electrical and mechanical, and point out remaining problem areas

  12. Micro-powder injection moulding of tungsten

    International Nuclear Information System (INIS)

    Zeep, B.

    2007-12-01

    For He-cooled Divertors as integral components of future fusion power plants, about 300000 complex shaped tungsten components are to be fabricated. Tungsten is the favoured material because of its excellent properties (high melting point, high hardness, high sputtering resistance, high thermal conductivity). However, the material's properties cause major problems for large scale production of complex shaped components. Due to the resistance of tungsten to mechanical machining, new fabrication technologies have to be developed. Powder injection moulding as a well established shaping technology for a large scale production of complex or even micro structured parts might be a suitable method to produce tungsten components for fusion applications but is not yet commercially available. The present thesis is dealing with the development of a powder injection moulding process for micro structured tungsten components. To develop a suitable feedstock, the powder particle properties, the binder formulation and the solid load were optimised. To meet the requirements for a replication of micro patterned cavities, a special target was to define the smallest powder particle size applicable for micro-powder injection moulding. To investigate the injection moulding performance of the developed feedstocks, experiments were successfully carried out applying diverse cavities with structural details in micro dimension. For debinding of the green bodies, a combination of solvent debinding and thermal debinding has been adopted for injection moulded tungsten components. To develop a suitable debinding strategy, a variation of the solvent debinding time, the heating rate and the binder formulation was performed. For investigating the thermal consolidation behaviour of tungsten components, sinter experiments were carried out applying tungsten powders suitable for micro-powder injection moulding. First mechanical tests of the sintered samples showed promising material properties such as a

  13. Injection envelope matching in storage rings

    International Nuclear Information System (INIS)

    Minty, M.G.; Spence, W.L.

    1995-05-01

    The shape and size of the transverse phase space injected into a storage ring can be deduced from turn-by-turn measurements of the transient behavior of the beam envelope in the ring. Envelope oscillations at 2 x the β-tron frequency indicate the presence of a β-mismatch, while envelope oscillations at the β-tron frequency are the signature of a dispersion function mismatch. Experiments in injection optimization using synchrotron radiation imaging of the beam and a fast-gated camera at the SLC damping rings are reported

  14. Fuel injection apparatus for internal combustion engine

    Energy Technology Data Exchange (ETDEWEB)

    Fujisawa, H; Kobayashi, H; Nagata, S

    1975-01-07

    A fuel injection apparatus for a rapid cut of fuel supply to internal combustion engines during deceleration is described. The fuel cut is achieved by an electromagnetic switch. The number of engine revolutions are determined by the movement of cam shafts, and one of the cam shafts is made of electroconductive and nonconductive materials which generate an intermittent electrical signal to the magnetic switch. The device can cut the fuel in any deceleration condition, therefore it is more advantageous than fuel injection utilizing the intake load variation which can operate only under certain deceleration conditions.

  15. Method and apparatus for injecting fluid

    Energy Technology Data Exchange (ETDEWEB)

    Hyde, W E

    1966-07-05

    A method and apparatus are described for injecting grouting material into porous, fractured, unconsolidated, or other formations, whose cohesion is to be increased and/or whose permeability is to be decreased. A tool for injecting the fluid consists of a packer and valves through which the pressurized fluid may pass from the interior of the tool to the packer to expand it. Another valve allows pressure fluid to be vented so as to allow contraction of the packer. A third valve allows a flow of pressurized flow out of the tool and into the material when a predetermined pressure within the tool has been attained. (9 claims)

  16. Nicolau Syndrome after Intramuscular Injection: 3 Cases

    Directory of Open Access Journals (Sweden)

    Seok-Kwun Kim

    2012-05-01

    Full Text Available Nicolau syndrome is a rare complication of intramuscular injection consisting of ischemicnecrosis of skin, soft tissue, and muscular tissue that arises locoregionally. The characteristicpattern is pain around the injection site, developing into erythema, a livedoid dermatitispatch, and necrosis of the skin, subcutaneous fat, and muscle tissue. Three patients wereinjected with drugs (diclofenac sodium, ketoprofen, meperidine for pain relief. Three patientscomplained of pain, and a skin lesion was observed, after which necrosis developed on theirbuttocks. Each patient underwent debridement and coverage. The wound healed uneventfully.We report three cases of Nicolau syndrome in the buttocks following diclofenac intramuscularinjection.

  17. Injection Therapies for Rotator Cuff Disease.

    Science.gov (United States)

    Lin, Kenneth M; Wang, Dean; Dines, Joshua S

    2018-04-01

    Rotator cuff disease affects a large proportion of the overall population and encompasses a wide spectrum of pathologies, including subacromial impingement, rotator cuff tendinopathy or tear, and calcific tendinitis. Various injection therapies have been used for the treatment of rotator cuff disease, including corticosteroid, prolotherapy, platelet-rich plasma, stem cells, and ultrasound-guided barbotage for calcific tendinitis. However, the existing evidence for these therapies remains controversial or sparse. Ultimately, improved understanding of the underlying structural and compositional deficiencies of the injured rotator cuff tissue is needed to identify the biological needs that can potentially be targeted with injection therapies. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Axial injection in Orsay superconducting cyclotron

    International Nuclear Information System (INIS)

    Depauw, J.; Kugler, M.F.; Legoff, A.; Potier, J.C.; Richomme, A.; Skowron, R.; Mandrillon, P.; Schapira, J.P.

    1983-01-01

    The compact superconducting cyclotron currently planned at IPN at Orsay is designed for light ion acceleration together with heavy ion acceleration. From the beginning, for this reason, a central geometry able to receive an inflector (to 90deg C) allowing the axial injection of low energy ion beams given by an outer source. The present study is aimed at showing the technical feasibility of theoretical results obtained on axial injection. First experimental study has been made of spatial repartition in three dimensions of electric potential developed by a central geometry of 3 electrodes. Then, the electric study of an electrostatic mirror has been made [fr

  19. Neutral beam injection in 2XIIB

    International Nuclear Information System (INIS)

    Hibbs, S.M.

    1975-01-01

    Integrated into the operation of the 2XIIB controlled fusion experiment is a 600-A, 20-keV neutral injection system: the highest neutral-beam current capacity of any existing fusion machine. This paper outlines the requirements of the injection system and the design features to which they led. Both mechanical and electrical aspects are discussed. Also included is a brief description of some operational aspects of the system and some of the things we have learned along the way, as well as a short history of the most significant developments

  20. Demoulding force in micro-injection moulding

    DEFF Research Database (Denmark)

    Griffiths, C.A.; Dimov, S.S.; Scholz, S.

    2012-01-01

    The paper reports an experimental study that investigates part demoulding behavior in micro injection moulding (MIM) with a focus on the effects of pressure (P) and temperature (T) on the demoulding forces. Demoulding of a microfluidics part is conducted and the four processing parameters of melt...... temperature (Tb), mould temperature (Tm), holding pressure (Ph) and injection speed (Vi) are analysed. The result using different combinations of process parameters were used to identify the best processing conditions in regards to demoulding forces when moulding micro parts....

  1. Injection profiles with radiation induced copolymers

    International Nuclear Information System (INIS)

    Knight, B.L.; Rhudy, J.S.; Gogarty, W.B.

    1976-01-01

    The injectivity profile of a heterogeneous formation and/or vertical conformance is improved by injecting an aqueous solution into the formation, the solution containing a polymer obtained as a product of radiation-induced polymerization of acrylamide and/or methacrylamide and acrylic acid, methacrylic acid, and/or alkali metal salts thereof. The polymerization is preferably carried out in a 10 to 60 percent aqueous solution with gamma radiation; the aqueous monomer solution preferably contains 25 to 99 percent acrylamide and 1 to 75 percent sodium acrylate. Immiscible, miscible, or miscible-like displacing processes can be used in conjunction with this invention. 20 claims

  2. Recent development in PWR zinc injection

    International Nuclear Information System (INIS)

    Ocken, H.; Fruzzetti, K.; Frattini, P.; Wood, C.J.

    2002-01-01

    Zinc injection to the reactor coolant system (RCS) of PWRs holds the promise to alleviate two key challenges facing PWR plant operators: (1) reducing degradation of coolant system materials, including nickel-base alloy tubing and lower alloy penetrations due to stress corrosion cracking, and (2) lowering shutdown dose rates. Primary water stress corrosion cracking (PWSCC) is a dominant tube failure mode at many plants. This paper summarizes recent observations from U. S. and international PWRs that have implemented zinc injection, focusing primarily on coolant chemistry and dose rate issues. It also provides a look at the future direction of EPRI-sponsored projects on this topic. (authors)

  3. Worldwide Injection Technique Questionnaire Study: Injecting Complications and the Role of the Professional.

    Science.gov (United States)

    Frid, Anders H; Hirsch, Laurence J; Menchior, Astrid R; Morel, Didier R; Strauss, Kenneth W

    2016-09-01

    From February 1, 2014, through June 30, 2015, 13,289 insulin-injecting patients from 423 centers in 42 countries participated in one of the largest surveys ever performed in diabetes. The first results of this survey are published elsewhere in this issue. Herein we report that the most common complication of injecting insulin is lipohypertrophy (LH), which was self-reported by 29.0% of patients and found by physical examination in 30.8% by health care professionals (HCPs). Patients with LH consumed a mean of 10.1 IU more insulin daily than patients without LH. Glycated hemoglobin levels averaged 0.55% higher in patients with vs without LH. Lipohypertrophy was associated with higher rates of unexplained hypoglycemia and glycemic variability as well as more frequent diabetic ketoacidosis, incorrect rotation of injection sites, use of smaller injection zones, longer duration of insulin use, and reuse of pen needles (each P<.05). Routine inspection of injection sites by the HCP was associated with lower glycated hemoglobin levels, less LH, and more correct injection site rotation. Patients were also more likely to rotate correctly if they received injection instructions from their HCP in the past 6 months. Fewer than 40% of patients claimed to have gotten such instructions in the past 6 months, and 10% said that they have never received training on how to inject correctly despite injecting for a mean of nearly 9 years. Use of these data should stimulate renewed commitment to optimizing insulin injection practices. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  4. Influence of fuel injection pressures on Calophyllum inophyllum methyl ester fuelled direct injection diesel engine

    International Nuclear Information System (INIS)

    Nanthagopal, K.; Ashok, B.; Karuppa Raj, R. Thundil

    2016-01-01

    Highlights: • Effect of injection pressure of Calophyllum inophyllum biodiesel is investigated. • Engine characteristics of 100% Calophyllum inophyllum biodiesel has been performed. • Calophyllum inophyllum is a non-edible source for biodiesel production. • Increase in injection pressure of biodiesel, improves the fuel economy. • Incylinder pressure characteristics of biodiesel follows similar trend as of diesel. - Abstract: The trend of using biodiesels in compression ignition engines have been the focus in recent decades due to the promising environmental factors and depletion of fossil fuel reserves. This work presents the effect of Calophyllum inophyllum methyl ester on diesel engine performance, emission and combustion characteristics at different injection pressures. Experimental investigations with varying injection pressures of 200 bar, 220 bar and 240 bar have been carried out to analyse the parameters like brake thermal efficiency, specific fuel consumption, heat release rate and engine emissions of direct injection diesel engine fuelled with 100% biodiesel and compared with neat diesel. The experimental results revealed that brake specific fuel consumption of C. inophyllum methyl ester fuelled engine has been reduced to a great extent with higher injection pressure. Significant reduction in emissions of unburnt hydrocarbons, carbon monoxide and smoke opacity have been observed during fuel injection of biodiesel at 220 bar compared to other fuel injection pressures. However oxides of nitrogen increased with increase in injection pressures of C. inophyllum methyl ester and are always higher than that of neat diesel. In addition the combustion characteristics of biodiesel at all injection pressures followed a similar trend to that of conventional diesel.

  5. CONCEPTUAL DESIGN OF THE NSLS-II INJECTION SYSTEM.

    Energy Technology Data Exchange (ETDEWEB)

    SHAFTAN,T.; ROSE, T.; PINAYEV, I.; HEESE, R.; BENGTSSON, J.; SKARITKA, J.; MENG, W.; OZAKI, S.; MEIER, R.; STELMACH, C.; LITVINENKO, V.; PJEROV, S.; SHARMA, S.; GANETIS, G.; HSEUH, H.C.; JOHNSON, E.D.; TSOUPAS, N.; GUO, W.; BEEBE-WANG, J.; LUCCIO, A.U.; YU, L.H.; RAPARIA, D.; WANG, D.

    2007-06-25

    We present the conceptual design of the NSLS-II injection system [1,2]. The injection system consists of a low-energy linac, booster and transport lines. We review two different injection system configurations; a booster located in the storage ring tunnel and a booster housed in a separate building. We briefly discuss main parameters and layout of the injection system components.

  6. Comparative effectiveness of injection therapies in lateral epicondylitis

    DEFF Research Database (Denmark)

    Krogh, Thøger Persson; Bartels, Else Marie; Ellingsen, Torkell Juulsgaad

    2013-01-01

    Injection therapy with glucocorticoids has been used since the 1950s as a treatment strategy for lateral epicondylitis (tennis elbow). Lately, several novel injection therapies have become available.......Injection therapy with glucocorticoids has been used since the 1950s as a treatment strategy for lateral epicondylitis (tennis elbow). Lately, several novel injection therapies have become available....

  7. Injection error monitor for KEK 12 GeV PS

    International Nuclear Information System (INIS)

    Shirakata, Masashi; Sato, Hikaru; Toyama, Takeshi; Marutsuka, Katsumi.

    1994-01-01

    The injection error monitor is now developing for an easy tuning of the main ring beam injection at the KEK 12 GeV proton synchrotron. The beam trajectory on the horizontal phase space plane is obtained by a test bench system. The injection error monitor proved to be available for the beam injection tuning. (author)

  8. The Third Injection Technique Workshop In Athens (TITAN)

    NARCIS (Netherlands)

    Frid, A.; Hirsch, L.; Gaspar, R.; Hicks, D.; Kreugel, G.; Liersch, J.; Letondeur, C.; Sauvanet, J. P.; Tubiana-Rufi, N.; Strauss, K.

    The first Injection Technique workshop brought together endocrinologists and injection experts from around the world in Strasbourg in 1997. From its work came groundbreaking recommendations which advanced best practices in areas such as the use of a skin fold when injecting. The second Injection

  9. Strategies and challenges for safe injection practice in developing countries

    OpenAIRE

    Gyawali, Sudesh; Rathore, Devendra Singh; Shankar, P Ravi; Kumar, KC Vikash

    2013-01-01

    Injection is one of the important health care procedures used globally to administer drugs. Its unsafe use can transmit various blood borne pathogens. This article aims to review the history and status of injection practices, its importance, interventions and the challenges for safe injection practice in developing countries. The history of injections started with the discovery of syringe in the early nineteenth century. Safe injection practice in developed countries was initiated in the earl...

  10. Variceal recurrence, rebleeding and survival after injection ...

    African Journals Online (AJOL)

    This study tested the validity of the hypothesis that eradication of oesophageal varices by repeated injection sclerotherapy would reduce recurrent variceal bleeding and death from bleeding oesophageal varices in a high risk cohort of patients with portal hypertension and cirrhosis. Patients and Methods: 306 alcoholic ...

  11. Modelling of injection processes in ladle metallurgy

    NARCIS (Netherlands)

    Visser, H.

    2016-01-01

    Ladle metallurgical processes constitute a portion of the total production chain of steel from iron ore. With these batch processes, the hot metal or steel transfer ladle is being used as a reactor vessel and a reagent is often injected in order to bring the composition of the hot metal or steel to

  12. Adverse reactions to injectable soft tissue fillers

    DEFF Research Database (Denmark)

    Requena, Luis; Requena, Celia; Christensen, Lise

    2011-01-01

    In recent years, injections with filler agents are often used for wrinkle-treatment and soft tissue augmentation by dermatologists and plastic surgeons. Unfortunately, the ideal filler has not yet been discovered and all of them may induce adverse reactions. Quickly biodegradable or resorbable ag...

  13. Gas injection pilot in the Hochleiten field

    Energy Technology Data Exchange (ETDEWEB)

    Potsch, K.; Ramberger, R.; Glantschnig, J.; Baumgarthuber, S.; Goessnitzer, F. [OMV AG, Wien (Austria)

    2004-07-01

    The Hochleiten field, located in the north of Vienna, is small in extension and highly compartmentalized. The main reservoir horizons are at a depth of approximately 1000 m. The oil quality shows high density and viscosity. Waterflood was initiated, but worked only in a part of the reservoir. Compartmentalization and lateral facies changes result in poor comunication and big pressure differences across the field. Some of the oil in place is not reached by primary or secondary recovery processes, and a solution was sought for accessing the bypassed oil. The screening process suggested gas injection as the most promising method. This contribution presents the first results of a field pilot project. Information will be given on the geology, additional lab work, and the realization in the field. The injection and production profiles of this pilot are presented. CO{sub 2} improved the inflow capacity of the injector, but the oil rates of the effected wells increased only slightly. In order to match the actual response of the reservoir, we had to adjust our reservoir model. Meanwhile N{sub 2} was injected as a tracer in one of the wells, to find out the preferred communication paths, before we proceeded with further gas injection. (orig.)

  14. Immunological Risk of Injectable Drug Delivery Systems

    NARCIS (Netherlands)

    Jiskoot, W.; van Schie, R.M.F.; Carstens, M.G.; Schellekens, H.

    2009-01-01

    Injectable drug delivery systems (DDS) such as particulate carriers and water-soluble polymers are being used and developed for a wide variety of therapeutic applications. However, a number of immunological risks with serious clinical implications are associated with administration of DDS. These

  15. Esophagus after injection sclerotherapy of varices

    Energy Technology Data Exchange (ETDEWEB)

    Brambs, H J; Billmann, P; Hoppe-Seyler, P; Buechsel, R

    1985-11-01

    Endoscopic sclerotherapy of esophageal varices is a widely used procedure. It reduces the frequency of rebleeding and improves the survival of cirrhotics with portal hypertension. The intravariceal or paravariceal injection of sclerosing agents causes structural changes of the esophageal wall recognisable radiologically. Stricture is a late complication which occurs in about 10 percent. In residual dysphagia balloon dilatation is recommended.

  16. Treatment of the Infection after Fat Injection

    Directory of Open Access Journals (Sweden)

    Seok-Kwun Kim

    2015-01-01

    Full Text Available For recent years, use of autologous fat injection has increased significantly in facial contouring surgery. Along with such increase in use, complications like atypical mycoplasma infection have been also on the increasing trend. The authors report two cases of Mycobacterium chelonae infection that occurred after autologous fat injection. Patients were treated as infection that resistant to common antibiotics and results were negative to routine culture and Gram staining. Acid-fast bacillus stain, polymerase chain reaction (PCR test and mycobacterial cultures were conducted for diagnosis under suspicion of atypical mycoplasma infection. Then, combination antibiotics therapy, surgical treatment, and steroid injection were performed for treatment. Both patients were diagnosed with Mycobacterium chelonae in PCR test. They were positive to mycobacterial cultures. Combination antibiotics therapy was repeated to improvement of symptom. However, they could not be free from side effects such as deformation in facial contour, scar and pigmentation even after full recovery. When chronic wound infections after autologous fat injection, we must suspect atypical or mycobacterial infection and conduct examinations for a early diagnosis and proper antibiotic therapy that is effective to the nontuberculous mycobacteria.

  17. An automatic injection system for rapid radiochemistry

    International Nuclear Information System (INIS)

    Nurmia, M.J.; Kreek, S.A.; Kadkhodayan, B.; Gregorich, K.E.; Lee, D.M.; Hoffman, D.C.

    1992-01-01

    A description is given of the Automated Injection System (AIS), a pneumatically actuated device for automated collection of nuclear reaction products from a He/KCl gas jet transport system. The AIS is used with the Automated Chemical Chromatographic Element Separation System; together these two devices facilitate completely automated separation procedures with improved speed and reproducibility

  18. Flow Injection Analysis in Industrial Biotechnology

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Miró, Manuel

    2009-01-01

    Flow injection analysis (FIA) is an analytical chemical continuous-flow (CF) method which in contrast to traditional CF-procedures does not rely on complete physical mixing (homogenisation) of the sample and the reagent(s) or on attaining chemical equilibria of the chemical reactions involved. Ex...

  19. Safe injection practices for administration of propofol.

    Science.gov (United States)

    King, Cecil A; Ogg, Mary

    2012-03-01

    Sepsis and postoperative infection can occur as a result of unsafe practices in the administration of propofol and other injectable medications. Investigations of infection outbreaks have revealed the causes to be related to bacterial growth in or contamination of propofol and unsafe medication practices, including reuse of syringes on multiple patients, use of single-use medication vials for multiple patients, and failure to practice aseptic technique and adhere to infection control practices. Surveys conducted by AORN and other researchers have provided additional information on perioperative practices related to injectable medications. In 2009, the US Food and Drug Administration and the Centers for Disease Control and Prevention convened a group of clinicians to gain a better understanding of the issues related to infection outbreaks and injectable medications. The meeting participants proposed collecting data to persuade clinicians to adopt new practices, developing guiding principles for propofol use, and describing propofol-specific, site-specific, and practitioner-specific injection techniques. AORN provides resources to help perioperative nurses reduce the incidence of postoperative infection related to medication administration. Copyright © 2012 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  20. PET radioligand injection for pig neuroimaging

    DEFF Research Database (Denmark)

    Alstrup, Aage Kristian Olsen; Munk, Ole Lajord; Landau, Anne M.

    2018-01-01

    Pigs are useful models in neuroimaging studies with positron emission tomography. Radiolabeled ligands are injected intravenously at the start of the scan and in pigs, the most easily accessible route of administration is the ear vein. However, in brain studies the short distance between the brai...

  1. Successful outcome after intravenous gasoline injection.

    Science.gov (United States)

    Domej, Wolfgang; Mitterhammer, Heike; Stauber, Rudolf; Kaufmann, Peter; Smolle, Karl Heinz

    2007-12-01

    Gasoline, ingested intentionally or accidentally, is toxic. The majority of reported cases of gasoline intoxication involve oral ingestion or inhalation. Data are scarce on complications and outcomes following hydrocarbon poisoning by intravenous injection. Following a suicide attempt by intravenous self-injection of 10 ml of gasoline, a 26-year-old medical student was admitted to the intensive care unit (ICU) with hemoptysis, symptoms of acute respiratory failure, chest pain, and severe abdominal cramps. Gas exchange was severely impaired and a chest x-ray indicated chemical pneumonitis. Initial treatment consisted of mechanical ventilation, supportive hyperventilation, administration of nitrogen oxide (NO), and prednisone. Unfortunately, the patient developed multi-organ dysfunction syndrome (MODS) complicated by life-threatening severe vasoplegia within 24 hours after gasoline injection. High doses of vasopressors along with massive amounts of parenteral fluids were necessary. Despite fluid replacement, renal function worsened and required hemofiltration on 5 sequential days. After 12 days of intensive care management, the patient recovered completely and was discharged to a psychiatric care facility. Intravenous gasoline injection causes major injury to the lungs, the organ bearing the first capillary bed encountered. Treatment of gasoline poisoning is symptomatic because no specific antidote is available. Early and aggressive supportive care may be conducive to a favorable outcome with minimal residual pulmonary sequelae.

  2. Injectable biomaterials for adipose tissue engineering

    International Nuclear Information System (INIS)

    Young, D A; Christman, K L

    2012-01-01

    Adipose tissue engineering has recently gained significant attention from materials scientists as a result of the exponential growth of soft tissue filler procedures being performed within the clinic. While several injectable materials are currently being marketed for filling subcutaneous voids, they often face limited longevity due to rapid resorption. Their inability to encourage natural adipose formation or ingrowth necessitates repeated injections for a prolonged effect and thus classifies them as temporary fillers. As a result, a significant need for injectable materials that not only act as fillers but also promote in vivo adipogenesis is beginning to be realized. This paper will discuss the advantages and disadvantages of commercially available soft tissue fillers. It will then summarize the current state of research using injectable synthetic materials, biopolymers and extracellular matrix-derived materials for adipose tissue engineering. Furthermore, the successful attributes observed across each of these materials will be outlined along with a discussion of the current difficulties and future directions for adipose tissue engineering. (paper)

  3. Nanostructuring steel for injection molding tools

    International Nuclear Information System (INIS)

    Al-Azawi, A; Smistrup, K; Kristensen, A

    2014-01-01

    The production of nanostructured plastic items by injection molding with ridges down to 400 nm in width, which is the smallest line width replicated from nanostructured steel shims, is presented. Here we detail a micro-fabrication method where electron beam lithography, nano-imprint lithography and ion beam etching are combined to nanostructure the planar surface of a steel wafer. Injection molded plastic parts with enhanced surface properties, like anti-reflective, superhydrophobic and structural colors can be achieved by micro- and nanostructuring the surface of the steel molds. We investigate the minimum line width that can be realized by our fabrication method and the influence of etching angle on the structure profile during the ion beam etching process. Trenches down to 400 nm in width have been successfully fabricated into a 316 type electro-polished steel wafer. Afterward a plastic replica has been produced by injection molding with good structure transfer fidelity. Thus we have demonstrated that by utilizing well-established fabrication techniques, nanostructured steel shims that are used in injection molding, a technique that allows low cost mass fabrication of plastic items, are produced. (paper)

  4. Functional nanostructures on injection molded plastic

    DEFF Research Database (Denmark)

    Johansson, Alicia Charlotte; Søgaard, Emil; Andersen, Nis Korsgaard

    Nanotechnology can be used to make inexpensive plastic parts with functional surfaces. The plastic parts can be molded using a standard injection molding process. The nanostructures are directly transferred from the surface of the molding tool to the surface of the molded plastic part during...

  5. HIV and Injection Drug Use PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    This 60 second public service announcement is based on the December 2016 CDC Vital Signs report. Sharing needles, syringes, and other injection equipment puts you at risk for getting HIV and other infections, including hepatitis. Learn how to reduce your HIV risk.

  6. Corticosteroid injection for de Quervain's tenosynovitis

    NARCIS (Netherlands)

    Peters-Veluthamaningal, Cyriac; van der Windt, Danielle A. W. M.; Winters, Jan C.; Jong, Betty Meyboom-de

    2009-01-01

    Back ground De Quervain's tenosynovitis is a disorder characterised by pain on the radial (thumb) side of the wrist and functional disability of the hand. It can be treated by corticosteroid injection, splinting and surgery. Objectives To summarise evidence on the efficacy and safety of

  7. RADIOLOGICAL TIPS Percutaneous thrombin injection for ...

    African Journals Online (AJOL)

    pseudoaneurysm sac has a typical 'yin-yang' sign. The neck is normally seen posteriorly and is usually thin and longitudinal. A large neck diameter (e.g. >10 mm) is a relative contra-indication for thrombin injection because of a slightly higher risk of distal embolisation. There are several thrombin preparations available.

  8. Investigations of needle-free jet injections.

    Science.gov (United States)

    Schramm-Baxter, J R; Mitragotri, S

    2004-01-01

    Jet injection is a needle-free drug delivery method in which a high-speed stream of fluid impacts the skin and delivers drugs. Although a number of jet injectors are commercially available, especially for insulin delivery, they have a low market share compared to needles possibly due to occasional pain associated with jet injection. Jets employed by the traditional jet injectors penetrate deep into the dermal and sub-dermal regions where the nerve endings are abundantly located. To eliminate the pain associated with jet injections, we propose to utilize microjets that penetrate only into the superficial region of the skin. However, the choice of appropriate jet parameters for this purpose is challenging owing to the multiplicity of factors that determine the penetration depth. Here, we describe the dependence of jet injections into human skin on the power of the jet. Dermal delivery of liquid jets was quantified using two measurements, penetration of a radiolabeled solute, mannitol, into skin and the shape of jet dispersion in the skin which was visualized using sulforhodamine B. The dependence of the amount of liquid delivered in the skin and the geometric measurements of jet dispersion on nozzle diameter and jet velocity was captured by a single parameter, jet power.

  9. Lake destratification induced by local air injection

    NARCIS (Netherlands)

    Kranenburg, C.

    1979-01-01

    Mathematical and physical modelling makes possible quantitative predictions regarding the destratification process brought about by the local injection of air at the bottom of a thermally stratified lake or reservoir. The mathematical model developed distinguishes between a near field and a far

  10. Progress in Titanium Metal Powder Injection Molding

    Directory of Open Access Journals (Sweden)

    Randall M. German

    2013-08-01

    Full Text Available Metal powder injection molding is a shaping technology that has achieved solid scientific underpinnings. It is from this science base that recent progress has occurred in titanium powder injection molding. Much of the progress awaited development of the required particles with specific characteristics of particle size, particle shape, and purity. The production of titanium components by injection molding is stabilized by a good understanding of how each process variable impacts density and impurity level. As summarized here, recent research has isolated the four critical success factors in titanium metal powder injection molding (Ti-MIM that must be simultaneously satisfied—density, purity, alloying, and microstructure. The critical role of density and impurities, and the inability to remove impurities with sintering, compels attention to starting Ti-MIM with high quality alloy powders. This article addresses the four critical success factors to rationalize Ti-MIM processing conditions to the requirements for demanding applications in aerospace and medical fields. Based on extensive research, a baseline process is identified and reported here with attention to linking mechanical properties to the four critical success factors.

  11. Water injection device for reactor container

    International Nuclear Information System (INIS)

    Sakaki, Isao.

    1996-01-01

    A pressure vessel incorporating a reactor core is placed and secured on a pedestal in a dry well of a reactor container. A pedestal water injection line is disposed opened at one end in a pedestal cavity passing through the side wall of the pedestal and led at the other end to the outside of the reactor container. A substitution dry well spray line is connected to a spray header disposed at the upper portion of the dry well. When the pressure vessel should be damaged by a molten reactor core and the molten reactor core should drop to the dry well upon occurrence of an accident, the molten reactor core on the floor of the pedestal is cooled by water injection from the pedestal water injection line. At the same time, the elevation of the pressure and the temperature in the reactor container is suppressed by the water injection of the substitution dry well spray line. This can avoid large scaled release of radioactive materials to the environmental circumference. (I.N.)

  12. Ultrasound guided local steroid injection versus extracorporeal ...

    African Journals Online (AJOL)

    Nayera Saber

    2011-12-17

    Dec 17, 2011 ... Results: There was a statistically significant reduction in plantar fascia .... Several previous studies evaluate the effects of either local ... The choice of ultrasound guided technique of steroid injection was related to the accuracy of application and supe- ..... chronic proximal plantar fasciitis: a meta analysis.

  13. Towards external injection in laser wakefield acceleration

    NARCIS (Netherlands)

    Stragier, X.F.D.

    2011-01-01

    In laser wakefield acceleration (LWA) a plasma wave is driven by a high intensity ultra short laser pulse and the longitudinal electric fields in the plasma wave are used to accelerate electron bunches. Electrons with an appropriate kinetic energy, injected on the right phase of the plasma wave, get

  14. Contraception With Medroxyprogesterone Injections in Port Harcourt ...

    African Journals Online (AJOL)

    Five accidental pregnancies occurred (Pearl Index 0.22 per hundred woman years). Defaults from scheduled injections and discontinuations of use were common with a low continuation rate (7.6%) at the end of the observation period. Secondary amenorrhoea was responsible for 33.3% of discontinuations. Conclusion: ...

  15. Retro-review of flow injection analysis

    DEFF Research Database (Denmark)

    Ruzicka, Jaromir; Hansen, Elo Harald

    2008-01-01

    It is indeed unusual for authors to review their own monograph – J. Ruzicka, E.H. Hansen, Flow Injection Analysis, 2nd Edition, Wiley, Chichester, West Sussex, UK, 1988. – and even more so if the book was published 20 years ago. Yet such an exercise might yield a perspective on the progress of an...

  16. Stability of fault submitted to fluid injections

    Science.gov (United States)

    Brantut, N.; Passelegue, F. X.; Mitchell, T. M.

    2017-12-01

    Elevated pore pressure can lead to slip reactivation on pre-existing fractures and faults when the coulomb failure point is reached. From a static point of view, the reactivation of fault submitted to a background stress (τ0) is a function of the peak strength of the fault, i.e. the quasi-static effective friction coefficient (µeff). However, this theory is valid only when the entire fault is affected by fluid pressure, which is not the case in nature, and during human induced-seismicity. In this study, we present new results about the influence of the injection rate on the stability of faults. Experiments were conducted on a saw-cut sample of westerly granite. The experimental fault was 8 cm length. Injections were conducted through a 2 mm diameter hole reaching the fault surface. Experiments were conducted at four different order magnitudes fluid pressure injection rates (from 1 MPa/minute to 1 GPa/minute), in a fault system submitted to 50 and 100 MPa confining pressure. Our results show that the peak fluid pressure leading to slip depends on injection rate. The faster the injection rate, the larger the peak fluid pressure leading to instability. Wave velocity surveys across the fault highlighted that decreasing the injection-rate leads to an increase of size of the fluid pressure perturbation. Our result demonstrate that the stability of the fault is not only a function of the fluid pressure requires to reach the failure criterion, but is mainly a function of the ratio between the length of the fault affected by fluid pressure and the total fault length. In addition, we show that the slip rate increases with the background effective stress and with the intensity of the fluid pressure pertubation, i.e. with the excess shear stress acting on the part of the fault pertubated by fluid injection. Our results suggest that crustal fault can be reactivated by local high fluid overpressures. These results could explain the "large" magnitude human-induced earthquakes

  17. Reduced injection pressures using a compressed air injection technique (CAIT): an in vitro study.

    Science.gov (United States)

    Tsui, Ban C H; Knezevich, Mark P; Pillay, Jennifer J

    2008-01-01

    High injection pressures have been associated with intraneural injection and persistent neurological injury in animals. Our objective was to test whether a reported simple compressed air injection technique (CAIT) would limit the generation of injection pressures to below a suggested 1,034 mm Hg limit in an in vitro model. After ethics board approval, 30 consenting anesthesiologists injected saline into a semiclosed system. Injection pressures using 30 mL syringes connected to a 22 gauge needle and containing 20 mL of saline were measured for 60 seconds using: (1) a typical "syringe feel" method, and (2) CAIT, thereby drawing 10 mL of air above the saline and compressing this to 5 mL prior to and during injections. All anesthesiologists performed the syringe feel method before introduction and demonstration of CAIT. Using CAIT, no anesthesiologist generated pressures above 1,034 mm Hg, while 29 of 30 produced pressures above this limit at some time using the syringe feel method. The mean pressure using CAIT was lower (636 +/- 71 vs. 1378 +/- 194 mm Hg, P = .025), and the syringe feel method resulted in higher peak pressures (1,875 +/- 206 vs. 715 +/- 104 mm Hg, P = .000). This study demonstrated that CAIT can effectively keep injection pressures under 1,034 mm Hg in this in vitro model. Animal and clinical studies will be needed to determine whether CAIT will allow objective, real-time pressure monitoring. If high pressure injections are proven to contribute to nerve injury in humans, this technique may have the potential to improve the safety of peripheral nerve blocks.

  18. UV-visible digital imaging of split injection in a Gasoline Direct Injection engine

    Directory of Open Access Journals (Sweden)

    Merola Simona Silvia

    2015-01-01

    Full Text Available Ever tighter limits on pollutant emissions and the need to improve energy conversion efficiency have made the application of gasoline direct injection (GDI feasible for a much wider scale of spark ignition engines. Changing the way fuel is delivered to the engine has thus provided increased flexibility but also challenges, such as higher particulate emissions. Therefore, alternative injection control strategies need to be investigated in order to obtain optimum performance and reduced environmental impact. In this study, experiments were carried out on a single-cylinder GDI optical engine fuelled with commercial gasoline in lean-burn conditions. The single-cylinder was equipped with the head of a commercial turbocharged engine with similar geometrical specifications (bore, stroke, compression ratio and wall guided fuel injection. Optical accessibility was ensured through a conventional elongated hollow Bowditch piston and an optical crown, accommodating a fused-silica window. Experimental tests were performed at fixed engine speed and injection pressure, whereas the injection timing and the number of injections were adjusted to investigate their influence on combustion and emissions. UV-visible digital imaging was applied in order to follow the combustion process, from ignition to the late combustion phase. All the optical data were correlated with thermodynamic analysis and measurements of exhaust emissions. Split injection strategies (i.e. two injections per cycle with respect to single injection increased combustion efficiency and stability thanks to an improvement of fuel air mixing. As a consequence, significant reduction in soot formation and exhaust emission with acceptable penalty in terms of HC and NOx were measured.

  19. Pharmacologic injection treatment of comitant strabismus

    Science.gov (United States)

    Debert, Iara; Miller, Joel M.; Danh, Kenneth K.; Scott, Alan B.

    2016-01-01

    Purpose To report the magnitude and stability of corrections in comitant horizontal strabismus achieved by injecting bupivacaine (BPX, optionally with epinephrine) and botulinum A toxin (BTXA) into extraocular muscles of alert adult subjects with electromyographic (EMG) guidance. Subjects & Methods A total of 55 adults with comitant horizontal strabismus participated in a prospective observational clinical series. Of these, 29 previously had undergone 1 or more unsuccessful strabismus surgeries; 4 had undergone other orbital surgeries. Thirty-one patients with esodeviations received BPX injections in a lateral rectus muscle, some with BTXA in the medial rectus; 24 patients with exodeviations received BPX in a medial rectus muscle, some with BTXA in the lateral rectus muscle. A second treatment (BPX, BTXA, or both) was administered to 27 patients who had residual strabismus after the first treatment. Five patients required additional injections. Clinical alignment was measured at 6 months and yearly thereafter through 5 years’ follow-up, with mean follow-up of 28 months. A successful outcome was defined as residual deviation ≤10Δ. Results On average, presenting misalignment of 23.8Δ (13.4°) was reduced at 28 months by 16.0Δ (9.1°), with successful outcomes in 56% of patients. Of patients with initial misalignments ≤25Δ, 66% had successful outcomes, with corrections averaging 13.2Δ (7.5°); of patients with larger misalignments, 40% had successful outcomes, with corrections averaging 20.9Δ (11.8°). Corrected alignments were stable over follow-ups as long as 5 years. Conclusions Injection treatments resulted in stable, clinically significant corrections in comitant horizontal strabismus. Injection provides a low-cost alternative to incisional strabismus surgery, particularly where it is desirable to minimize surgical anesthesia and avoid extraocular scarring. PMID:27079589

  20. The PEP II injection kicker system

    International Nuclear Information System (INIS)

    Pappas, G.C.; Donaldson, A.R.; Williams, D.

    1997-07-01

    PEP II or the B Factory consists of two asymmetric storage rings. The injection energy for electrons is 9 GeV, while that for positrons is 3.1 GeV. The bend angle into the high energy ring (HER) is 0.35 m-rad, and the angle into the low energy ring (LER) is 0.575 m-rad. The magnetic length for the HER kicker is 0.85 m, and 0.55 m for the LER kicker. The field produced by the magnet is therefore 123.5 G for the HER, and 132 G for the LER. Each ring has a kicker magnet upstream of the injection line which is used to distort the orbit of the stored beam. An identical magnet downstream of the injection line is used to restore the orbit of the stored beam and inject the incoming beam. The two magnets are driven in parallel by the modulator. The apeture of the magnets is 3.86x3.46 cm (HxV). Therefore the current required to drive the HER is 863 A, while for the LER it is 756 A. The inductance of the magnet is approximately 1.4 uH/m. The current pulse is a critically damped sinusoid with a rise time of less than 300 ns. A kicker system has been designed which can be used for injection of both beams by varying the charge of voltage. The modulator uses a conjugate circuit to match the impedance of the magnet, and coupling to the beam chamber

  1. Addendum: First injection technique recommendations for patients with diabetes, Forum for Injection Techniques India

    Directory of Open Access Journals (Sweden)

    Sanjay Kalra

    2013-01-01

    Full Text Available The forum for injection techniques, India recommendation, the first ever in the country on insulin injcetion techniques, have covered the science and the art of insulin injection technique in an exhaustive manner. However, a few gaps were identified in the document, which are addressed in the current addendum. This article focuses on insulin injection technique in special clinical situations, including geriatric people, women in pregnancy and those with dermatological or surgical disease who live with diabetes. The addendum also covers salient features of administration of insulin using the insulin pump.

  2. CT-guided cervical nerve root injections: comparing the immediate post-injection anesthetic-related effects of the transforaminal injection with a new indirect technique

    International Nuclear Information System (INIS)

    Sutter, Reto; Pfirrmann, Christian W.A.; Peterson, Cynthia K.; Zanetti, Marco; Hodler, Juerg

    2011-01-01

    To describe an ''indirect'' cervical nerve root injection technique with a dorsal approach that should carry less inherent risk than the ''direct'' cervical transforaminal injection approach, and to compare the immediate post-injection results of the two procedures. The indirect and direct cervical nerve root injection procedures are described in detail. Fifty-three consecutive patients receiving the indirect nerve root injections during 2009-2010 were age- and gender-matched to 53 patients who underwent direct transforaminal nerve root injections performed in 2006. Pain level data were collected immediately before and 20-30 min after each procedure. The percentages of pain change in the two groups were compared using the unpaired Student's t test. Fifty-two men (mean age 49) and 54 women (mean age 55) were included. The mean percentage of pain reduction for patients receiving indirect nerve root injections was 38.4% and for those undergoing the direct nerve root injections approach it was 43.2%. This was not significantly different (P = 0.455). No immediate or late adverse effects were reported after either injection procedure. The indirect cervical nerve root injection procedure is a potentially safer alternative to direct cervical transforaminal nerve root injections. The short-term pain reduction is similar using the two injection methods. (orig.)

  3. Radial oil injection applied to main engine bearings: evaluation of injection control rules

    DEFF Research Database (Denmark)

    Estupiñan, EA; Santos, Ilmar

    2012-01-01

    , the dynamic behaviour of the main bearing of a medium-size engine is theoretically analysed when the engine operates with controllable radial oil injection and four different injection control rules. The theoretical investigation is based on a single-cylinder combustion engine model. The performance......The performance of main bearings in a combustion engine affects key functions such as durability, noise and vibration. Thus, with the aim of reducing friction losses and vibrations between the crankshaft and the bearings, the work reported here evaluates different strategies for applying...... controllable radial oil injection to main crankshaft journal bearings. In an actively lubricated bearing, conventional hydrodynamic lubrication is combined with controllable hydrostatic lubrication, where the oil injection pressures can be modified depending on the operational conditions. In this study...

  4. Existing Evidence on Ultrasound-Guided Injections in Sports Medicine.

    Science.gov (United States)

    Daniels, Eldra W; Cole, David; Jacobs, Bret; Phillips, Shawn F

    2018-02-01

    Office-based ultrasonography has become increasingly available in many settings, and its use to guide joint and soft tissue injections has increased. Numerous studies have been conducted to evaluate the use of ultrasound-guided injections over traditional landmark-guided injections, with a rapid growth in the literature over the past few years. A comprehensive review of the literature was conducted to demonstrate increased accuracy of ultrasound-guided injections regardless of anatomic location. In the upper extremity, ultrasound-guided injections have been shown to provide superior benefit to landmark-guided injections at the glenohumeral joint, the subacromial space, the biceps tendon sheath, and the joints of the hand and wrist. Ultrasound-guided injections of the acromioclavicular and the elbow joints have not been shown to be more efficacious. In the lower extremity, ultrasound-guided injections at the knee, ankle, and foot have superior efficacy to landmark-guided injections. Conclusive evidence is not available regarding improved efficacy of ultrasound-guided injections of the hip, although landmark-guided injection is performed less commonly at the hip joint. Ultrasound-guided injections are overall more accurate than landmark-guided injections. While current studies indicate that ultrasound guidance improves efficacy and cost-effectiveness of many injections, these studies are limited and more research is needed.

  5. Meta-Analysis of the Clinical Value of Danshen Injection and Huangqi Injection in Liver Cirrhosis

    Directory of Open Access Journals (Sweden)

    Changtai Zhu

    2013-01-01

    Full Text Available Objective. To evaluate the clinical value of Danshen injection and Huangqi injection for the treatment of liver cirrhosis. Methods. The Chinese Biomedical Literature Database (CBM, Chinese Scientific Journals Full-Text Database (VIP, Wanfang Database, China National Knowledge Infrastructure (CNKI, PubMed, and EMBASE database were searched to collect the literatures about the randomized controlled trials involving the treatment of liver cirrhosis with Danshen injection combined with Huangqi injection, and the data analyses were performed using RevMan 4.2 software. Results. A total of 11 studies involving 1086 patients (trials group: 554 cases, control group: 532 cases were included in this study. Compared with those in control group, the meta-analysis showed-that the total effectiveness rate and the level of serum albumin increased, while serum total bilirubin, alanine transmninase, type III procollagen, hyaluronic acid, laminin, and type-IV collagen decreased in trials group. The Jadad score ranged from 1 to 2 and the funnel plot analysis suggests that publication bias may occur. Conclusions. Danshen injection combined with Huangqi injection may promote the curative efficacy of liver cirrhosis, which is a promising novel treatment approach. The exact outcome needs to perform rigorously designed, multicenter, and large randomized controlled trials.

  6. Injection and Non-Injection Drug Use and Infectious Disease in Baltimore City: Differences by Race

    Science.gov (United States)

    Keen, Larry; Khan, Maria; Clifford, Lisa; Harrell, Paul T.; Latimer, William W.

    2014-01-01

    Purpose The current study examines differences in the prevalence of biologically-confirmed hepatitis C virus (HCV), HIV, and coinfection between Black and White adult cocaine/heroin users across three drug use subgroups identified in previous research (Harrell et al, 2012): non-injection smoking crack/nasal heroin users, heroin injectors, and polydrug injectors. Results 59% of the 482 participants in the study were male. Significant race differences emerged between drug use subgroup memberships. Non-injection smoking crack/nasal heroin users were predominantly Black (75%), while heroin injectors and polydrug injectors were predominantly White (69% and 72%, respectively). Polydrug injectors accounted for nearly three quarters of the HCV positive diagnoses in Whites. Though HIV disease status, stratified by race, did not differ significantly between drug use subgroups, the non-injection smoking crack/nasal heroin subgroup contained over half of the HIV positive diagnoses in the sample and was predominantly Black. Despite much lower rates of injection, Blacks (8%) had a higher prevalence of coinfection than Whites (3%; X2 (2) = 6.18, p = .015). Conclusions The current findings are consistent with trends in recent HIV transmission statistics where sexual activity has overtaken injection drug use as a HIV risk factor. The current findings also provide further support to the notion of injection drug use as an exceedingly high-risk behavior for HCV and coinfection, specifically those who are polysubstance injectors. PMID:24837755

  7. Temporal fossa defects: techniques for injecting hyaluronic acid filler and complications after hyaluronic acid filler injection.

    Science.gov (United States)

    Juhász, Margit Lai Wun; Marmur, Ellen S

    2015-09-01

    Facial changes with aging include thinning of the epidermis, loss of skin elasticity, atrophy of muscle, and subcutaneous fat and bony changes, all which result in a loss of volume. As temporal bones become more concave, and the temporalis atrophies and the temporal fat pad decreases, volume loss leads to an undesirable, gaunt appearance. By altering the temporal fossa and upper face with hyaluronic acid filler, those whose specialty is injecting filler can achieve a balanced and more youthful facial structure. Many techniques have been described to inject filler into the fossa including a "fanned" pattern of injections, highly diluted filler injection, and the method we describe using a three-injection approach. Complications of filler in the temporal fossa include bruising, tenderness, swelling, Tyndall effect, overcorrection, and chewing discomfort. Although rare, more serious complications include infection, foreign body granuloma, intravascular necrosis, and blindness due to embolization into the ophthalmic artery. Using reversible hyaluronic acid fillers, hyaluronidase can be used to relieve any discomfort felt by the patient. Injectors must be aware of the complications that may occur and provide treatment readily to avoid morbidities associated with filler injection into this sensitive area. © 2015 Wiley Periodicals, Inc.

  8. Delayed flumazenil injection after endoscopic sedation increases patient satisfaction compared with immediate flumazenil injection.

    Science.gov (United States)

    Chung, Hyun Jung; Bang, Byoung Wook; Kim, Hyung Gil; Kwon, Kye Sook; Shin, Yong Woon; Jeong, Seok; Lee, Don Haeng; Park, Shin Goo

    2014-01-01

    Flumazenil was administered after the completion of endoscopy under sedation to reduce recovery time and increase patient safety. We evaluated patient satisfaction after endoscopy under sedation according to the timing of a postprocedural flumazenil injection. In total, 200 subjects undergoing concurrent colonoscopy and upper endoscopy while sedated with midazolam and meperidine were enrolled in our investigation. We randomly administered 0.3 mg of flumazenil either immediately or 15 minutes after the endoscopic procedure. A postprocedural questionnaire and next day telephone interview were conducted to assess patient satisfaction. Flumazenil injection timing did not affect the time spent in the recovery room when comparing the two groups of patients. However, the subjects in the 15 minutes injection group were more satisfied with undergoing endoscopy under sedation than the patients in the immediate injection group according to the postprocedural survey (p=0.019). However, no difference in overall satisfaction, memory, or willingness to undergo a future endoscopy was observed between the two groups when the telephone survey was conducted on the following day. This study demonstrated that a delayed flumazenil injection after endoscopic sedation increased patient satisfaction without prolonging recovery time, even though the benefit of the delayed flumazenil injection did not persist into the following day.

  9. Injection into the LNLS UVX electron storage ring

    International Nuclear Information System (INIS)

    Lin, Liu

    1991-01-01

    To inject the 1.15 GeV electron storage ring - UVX - a beam from a linear accelerator - MAIRA - is used. The electrons are injected and accumulated at low energy (100MeV) until the nominal current of 100 mA is reached and than are ramped to the nominal energy. A study on a conventional injection scheme has been carried out. Two injection modes are investigated: injection with the phase ellipse parameters matched and mismatched to the ring's acceptance. The mismatched mode is optimized to fit the maximum of the injected beam into the acceptance

  10. Injection practice in Kaski district, Western Nepal: a community perspective.

    Science.gov (United States)

    Gyawali, Sudesh; Rathore, Devendra Singh; Shankar, Pathiyil Ravi; Kumar, Vikash K C; Maskey, Manisha; Jha, Nisha

    2015-04-29

    Previous studies have shown that unsafe injection practice is a major public health problem in Nepal but did not quantify the problem. The present community-based study was planned to: 1) quantify injection usage, 2) identify injection providers, 3) explore differences, if any, in injection usage and injection providers, and 4) study and compare people's knowledge and perception about injections between the urban and rural areas of Kaski district. A descriptive, cross-sectional mixed-methods study was conducted from July to November 2012, using a questionnaire based survey and focus group discussions (FGDs). A semi-structured questionnaire advocated by the World Health Organization was modified and administered to household heads and injection receivers in selected households and the FGDs were conducted using a topic guide. The district was divided into urban and rural areas and 300 households from each area were selected. Twenty FGDs were held. In 218 households (36.33%) [99 in urban and 119 in rural] one or more members received at least one injection. During the three month recall period, 258 subjects (10.44%) reported receiving injection(s) with a median of two injections. The average number of injections per person per year was calculated to be 2.37. Health care workers (34.8%), staff of medical dispensaries (37.7%), physicians (25.2%), and traditional healers (2.3%) were consulted by the respondents for their basic health care needs and for injections. Compared to urban respondents, more rural respondents preferred injections for fever (p injections due to injections being perceived by them as being powerful, fast-acting, and longer lasting than oral pills. More than 82% of respondents were aware of, and named, at least one disease transmitted by using unsterile syringes during injection administration or when syringes are shared between people. Less preference for injections and high awareness about the association between injections and injection

  11. Rapid assessment of injection practices in Cambodia, 2002

    Directory of Open Access Journals (Sweden)

    Goldstein Susan

    2005-06-01

    Full Text Available Abstract Background Injection overuse and unsafe injection practices facilitate transmission of bloodborne pathogens such as hepatitis B virus (HBV, hepatitis C virus (HCV, and human immunodeficiency virus (HIV. Anecdotal reports of unsafe and unnecessary therapeutic injections and the high prevalence of HBV (8.0%, HCV (6.5%, and HIV (2.6% infection in Cambodia have raised concern over injection safety. To estimate the magnitude and patterns of such practices, a rapid assessment of injection practices was conducted. Methods We surveyed a random sample of the general population in Takeo Province and convenience samples of prescribers and injection providers in Takeo Province and Phnom Penh city regarding injection-related knowledge, attitudes, and practices. Injection providers were observed administering injections. Data were collected using standardized methods adapted from the World Health Organization safe injection assessment guidelines. Results Among the general population sample (n = 500, the overall injection rate was 5.9 injections per person-year, with 40% of participants reporting receipt of ≥ 1 injection during the previous 6 months. Therapeutic injections, intravenous infusions, and immunizations accounted for 74%, 16% and 10% of injections, respectively. The majority (>85% of injections were received in the private sector. All participants who recalled their last injection reported the injection was administered with a newly opened disposable syringe and needle. Prescribers (n = 60 reported that 47% of the total prescriptions they wrote included a therapeutic injection or infusion. Among injection providers (n = 60, 58% recapped the syringe after use and 13% did not dispose of the used needle and syringe appropriately. Over half (53% of the providers reported a needlestick injury during the previous 12 months. Ninety percent of prescribers and injection providers were aware HBV, HCV, and HIV were transmitted through unsafe

  12. Surface micro topography replication in injection moulding

    DEFF Research Database (Denmark)

    Arlø, Uffe Rolf

    Thermoplastic injection moulding is a widely used industrial process that involves surface generation by replication. The surface topography of injection moulded plastic parts can be important for aesthetical or technical reasons. With the emergence of microengineering and nanotechnology additional...... importance of surface topography follows. In general the replication is not perfect and the topography of the plastic part differs from the inverse topography of the mould cavity. It is desirable to be able to control the degree of replication perfection or replication quality. This requires an understanding...... of the physical mechanisms of replication. Such understanding can lead to improved process design and facilitate in-line process quality control with respect to surface properties. The purpose of the project is to identify critical factors that affect topography replication quality and to obtain an understanding...

  13. Dosimetric implications of the infiltrated injection

    International Nuclear Information System (INIS)

    Castronovo, F.P.; McKusick, K.A.; Strauss, H.W.

    1984-01-01

    Following inadvertent infiltration of a radiopharmaceutical, there is variable and uncertain uptake in target tissue. Concomitantly, there is also a concern for the radiation dose to the infiltrated site. This investigation determined the clearance and radiation burdens from various radiopharmaceutical infiltrates in a rat model. Nine separate sites were studied for: Tc-99m microspheres; Tc-99m MDP; Ga-67 citrate; and Tl-201 chloride. Following sc injection on the shaven posteriors of anesthetized adult male Sprague-Dawley rats, gamma camera and computer data were collected up to 24 hours. The resulting data were expressed semilogarithmically as the mean (N = 9) of the ''% retained at site'' as a f(time) after injection. Nonparticulate agents showed a tri-exponential release pattern from each site, whereas the microspheres remained for an extended period of time. Using these pharma-cokinetic curves, the % remaining at each site for various times, and rems/mCi per lcc infiltrate was determined

  14. Surface microstructure replication in injection molding

    DEFF Research Database (Denmark)

    Theilade, Uffe Arlø; Hansen, Hans Nørgaard

    2006-01-01

    topography is transcribed onto the plastic part through complex mechanisms. This replication, however, is not perfect, and the replication quality depends on the plastic material properties, the topography itself, and the process conditions. This paper describes and discusses an investigation of injection...... molding of surface microstructures. The fundamental problem of surface microstructure replication has been studied. The research is based on specific microstructures as found in lab-on-a-chip products and on rough surfaces generated from EDM (electro discharge machining) mold cavities. Emphasis is put...... on the ability to replicate surface microstructures under normal injection-molding conditions, i.e., with commodity materials within typical process windows. It was found that within typical process windows the replication quality depends significantly on several process parameters, and especially the mold...

  15. An injectable acoustic transmitter for juvenile salmon

    Science.gov (United States)

    Deng, Z. D.; Carlson, T. J.; Li, H.; Xiao, J.; Myjak, M. J.; Lu, J.; Martinez, J. J.; Woodley, C. M.; Weiland, M. A.; Eppard, M. B.

    2015-01-01

    Salmon recovery and the potential detrimental effects of dams on fish have been attracting national attention due to the environmental and economic implications. In recent years acoustic telemetry has been the primary method for studying salmon passage. However, the size of the existing transmitters limits the minimum size of fish that can be studied, introducing a bias to the study results. We developed the first acoustic fish transmitter that can be implanted by injection instead of surgery. The new injectable transmitter lasts four times longer and weighs 30% less than other transmitters. Because the new transmitter costs significantly less to use and may substantially reduce adverse effects of implantation and tag burden, it will allow for study of migration behavior and survival of species and sizes of fish that have never been studied before. The new technology will lead to critical information needed for salmon recovery and the development of fish-friendly hydroelectric systems.

  16. MgO by injection CVD

    International Nuclear Information System (INIS)

    Abrutis, A.; Kubilius, V.; Teiserkis, A.; Bigelyte, V.; Vengalis, B.; Jukna, A.; Butkute, R.

    1997-01-01

    Epitaxial YBa 2 Cu 3 O 7 layers with 45 in-plane orientation have been grown by injection CVD on MgO substrates polished off-axis to within 1.4-1.9 of the [100] direction. This new single-source CVD process is based on computer-controlled injection of precise microdoses of a metal-organic precursor solution into a CVD reactor. A wide range of solution compositions was tested to investigate compositional effects on phase purity, surface morphology, texturing and superconducting properties of the prepared films. The highest quality films with pure 45 texture had a smooth surface, zero resistance T c (R=0) of 88-89 K, and critical current density J c (77 K) above 10 6 A/cm 2 . (orig.) and critical current density J c (77 K) above 10 6 A/cm 2 . (orig.)

  17. An injection system for a linear accelerator

    International Nuclear Information System (INIS)

    Santos, A.C.R.

    1978-03-01

    An injection system for the Linear Accelerator is developed using the parameters of machines at the Centro Brasileiro de Pesquisas Fisicas and the Instituto Militar de Engenharia. The proposed system consists basically of a prebuncher and a chopper. The pre-buncher is used to improve the energy resolution and also to increase the accelerator target current. The chopper is used to remove from the beam the electrons that have no possibility of attaining the desired energy and that are usually lost in the walls and the cavity tube, thus producing undesirable background. Theoretical development of the chopper is performed in order to obtain its dimensions for future construction. The complete design the pre-buncher and its feed supply system and the experimental verication of its performance are also presented. It is intended to give the necessary information for the design and construction of the complete injection system proposed. (Author) [pt

  18. VLF wave injections from the ground

    Science.gov (United States)

    Helliwell, R. A.

    1983-01-01

    Experiments on wave-particle interactions using VLF whistler-mode waves injected into the magnetosphere from Antartica are described. The injected signals are single-frequency coherent waves whose amplitudes and frequencies may be changed slowly with time, or else two or more coherent wave trains transmitted simultaneously to determine the nature of the response to multifrequency excitation. The waves may be amplified 30 dB or more and may trigger intense emissions having bandwidths that vary from a few to several hundred Hertz. In most cases significant growth and triggering occur only when the driving signal is essentially monochromatic (bandwidth 10 Hz). If two frequencies are transmitted simultaneously the signal at the lower frequency tends to be suppressed by 20 dB or more. These results are interpreted in terms of a feedback interaction between the waves and counter-streaming cyclotron resonant electrons in a region several hundred wavelengths long, centered on the magnetic equator.

  19. Advanced fusion in ICRF injected plasmas

    International Nuclear Information System (INIS)

    Carpignano, F.; Coppi, B.; Detragiache, P.; Migliuolo, S.; Nassi, M.; Rogers, B.

    1994-01-01

    Fusion burning of a D- 3 He mixture in a high density, high magnetic field, compact toroidal experiment (Ignitor) with a high injected power density at the ion cyclotron frequency (ICRF) is investigated. A superthermal tail (with energies exceeding 1 MeV in the central part of the plasma column) is induced in the distribution of the minority 3 He population ( 0 20 m -3 ). This stems from the high value of the peak RF power density absorbed by the minority species (ρ RF ∼ 60 MW/m 3 ) that should be obtained in Ignitor when the total injected power is about 18 MW. This experiment is suitable to begin the study of advanced fusion burning, because of the high plasma currents (I p 3 He fusion powers of the order of 1 MW should be attained. (author) 8 refs., 3 figs

  20. Nanostructuring steel for injection molding tools

    DEFF Research Database (Denmark)

    Al-Azawi, A.; Smistrup, Kristian; Kristensen, Anders

    2014-01-01

    The production of nanostructured plastic items by injection molding with ridges down to 400 nm in width, which is the smallest line width replicated from nanostructured steel shims, is presented. Here we detail a micro-fabrication method where electron beam lithography, nano-imprint lithography...... and ion beam etching are combined to nanostructure the planar surface of a steel wafer. Injection molded plastic parts with enhanced surface properties, like anti-reflective, superhydrophobic and structural colors can be achieved by micro-and nanostructuring the surface of the steel molds. We investigate...... the minimum line width that can be realized by our fabrication method and the influence of etching angle on the structure profile during the ion beam etching process. Trenches down to 400 nm in width have been successfully fabricated into a 316 type electro-polished steel wafer. Afterward a plastic replica...

  1. Injection molded self-cleaning surfaces

    DEFF Research Database (Denmark)

    Søgaard, Emil

    that are superhydrophobic based on topography rather than chemical compounds. Therefore, a novel method for fabricating superhydrophobic polymer surfaces with excellent water-repellant properties is developed. The method is based on microstructure fabrication and superposed nanostructures on silicon wafers. The nano......- and microstructured silicon is electroplated with nickel and the resulting nickel shim with inverse polarity is used in an injection molding process. A versatile injection molding process capable of producing different nano- and microstructures on areas larger than 10 cm2 is developed. Variotherm mold heating is used...... hierarchical structures with nanograss and holes. Water wetting tests are carried out using a pressure cell to control the water pressure. Microscopic wetting behavior of the structures is studied by optical transmission microscopy. Interestingly, it is found that the surface chemistry of the polymer changes...

  2. Water injection profiling by nuclear logging

    International Nuclear Information System (INIS)

    Arnold, D.M.

    1980-01-01

    This invention relates to nuclear logging techniques for determining the volume flow rates and flow directions of injected water moving behind a wellbore casing. The apparatus includes a sonde equipped with a neutron source and dual radiation detectors. Oxygen in the neutron irradiated water is transmitted to 16 N and the resultant primary and Compton scattered gamma rays are detected in two energy windows by both detectors. Count rate data is analysed in terms of the windows to obtain linear flow velocities for water flow within and behind the casing. Volume flow rates are determined for upward and downward flow, and horizontal volume flow into the surrounding formation is calculated. A complete injection profile may thus be obtained. (U.K.)

  3. BEAMS3D Neutral Beam Injection Model

    Energy Technology Data Exchange (ETDEWEB)

    Lazerson, Samuel

    2014-04-14

    With the advent of applied 3D fi elds in Tokamaks and modern high performance stellarators, a need has arisen to address non-axisymmetric effects on neutral beam heating and fueling. We report on the development of a fully 3D neutral beam injection (NBI) model, BEAMS3D, which addresses this need by coupling 3D equilibria to a guiding center code capable of modeling neutral and charged particle trajectories across the separatrix and into the plasma core. Ionization, neutralization, charge-exchange, viscous velocity reduction, and pitch angle scattering are modeled with the ADAS atomic physics database [1]. Benchmark calculations are presented to validate the collisionless particle orbits, neutral beam injection model, frictional drag, and pitch angle scattering effects. A calculation of neutral beam heating in the NCSX device is performed, highlighting the capability of the code to handle 3D magnetic fields.

  4. Injectable biomaterials for minimally invasive orthopedic treatments.

    Science.gov (United States)

    Jayabalan, M; Shalumon, K T; Mitha, M K

    2009-06-01

    Biodegradable and injectable hydroxy terminated-poly propylene fumarate (HT-PPF) bone cement was developed. The injectable formulation consisting HT-PPF and comonomer, n-vinyl pyrrolidone, calcium phosphate filler, free radical catalyst, accelerator and radiopaque agent sets rapidly to hard mass with low exothermic temperature. The candidate bone cement attains mechanical strength more than the required compressive strength of 5 MPa and compressive modulus 50 MPa. The candidate bone cement resin elicits cell adhesion and cytoplasmic spreading of osteoblast cells. The cured bone cement does not induce intracutaneous irritation and skin sensitization. The candidate bone cement is tissue compatible without eliciting any adverse tissue reactions. The candidate bone cement is osteoconductive and inductive and allow osteointegration and bone remodeling. HT-PPF bone cement is candidate bone cement for minimally invasive radiological procedures for the treatment of bone diseases and spinal compression fractures.

  5. Computer-aided injection molding system

    Science.gov (United States)

    Wang, K. K.; Shen, S. F.; Cohen, C.; Hieber, C. A.; Isayev, A. I.

    1982-10-01

    Achievements are reported in cavity-filling simulation, modeling viscoelastic effects, measuring and predicting frozen-in birefringence in molded parts, measuring residual stresses and associated mechanical properties of molded parts, and developing an interactive mold-assembly design program and an automatic NC maching data generation and verification program. The Cornell Injection Molding Program (CIMP) consortium is discussed as are computer user manuals that have been published by the consortium. Major tasks which should be addressed in future efforts are listed, including: (1) predict and experimentally determine the post-fillin behavior of thermoplastics; (2) simulate and experimentally investigate the injection molding of thermosets and filled materials; and (3) further investigate residual stresses, orientation and mechanical properties.

  6. Surface Micro Topography Replication in Injection Moulding

    DEFF Research Database (Denmark)

    Arlø, Uffe Rolf; Hansen, Hans Nørgaard; Kjær, Erik Michael

    2005-01-01

    The surface micro topography of injection moulded plastic parts can be important for aesthetical and technical reasons. The quality of replication of mould surface topography onto the plastic surface depends among other factors on the process conditions. A study of this relationship has been...... carried out with rough EDM (electrical discharge machining) mould surfaces, a PS grade, and by applying established three-dimensional topography parameters. Significant quantitative relationships between process parameters and topography parameters were established. It further appeared that replication...

  7. Electron injection in diodes with field emission

    International Nuclear Information System (INIS)

    Denavit, J.; Strobel, G.L.

    1986-01-01

    This paper presents self-consistent steady-state solutions of the space charge, transmitted current, and return currents in diodes with electron injection from the cathode and unlimited field emission of electrons and ions from both electrodes. Time-dependent particle simulations of the diode operation confirm the analytical results and show how these steady states are reached. The results are applicable to thermionic diodes and to photodiodes

  8. Method for Converter Synchronization with RF Injection

    OpenAIRE

    Joshua P. Bruckmeyer; Ivica Kostanic

    2015-01-01

    This paper presents an injection method for synchronizing analog to digital converters (ADC). This approach can eliminate the need for precision routed discrete synchronization signals of current technologies, such as JESD204. By eliminating the setup and hold time requirements at the conversion (or near conversion) clock rate, higher sample rate systems can be synchronized. Measured data from an existing multiple ADC conversion system was used to evaluate the method. Coherent beams were simu...

  9. The Re-injection Loop concept

    DEFF Research Database (Denmark)

    Holst Fischer, Christian; Malmgren-Hansen, Bjørn; Uellendahl, Hinrich

    per ton. Based on previous studies on using pretreatment for enhancing the biogas yield of these feedstocks, a new concept called Re-Injection Loop was developed by combining separation and recirculation of the digested fiber fraction with pretreatment of the recalcitrant lignocellulosic fiber...... fraction. The EU project BIOMAN is currently investigating different technologies for separation, mechanical pretreatment and enzymatic hydrolysis to establish an economically viable concept for manure-based biogas plants....

  10. PLT neutral injection ignitron accelerating supply

    International Nuclear Information System (INIS)

    Ashcroft, D.L.; Murray, J.G.; Newman, R.A.; Peterson, F.L.

    1975-11-01

    A phase-controlled rectifier was designed for the accelerating supply on the PLT Neutral Beam Injection system at PPPL. The rectifier must furnish 70 amperes at up to 50 KV for 300 milliseconds, with a duty cycle of up to 10 percent. Protection of the injectors requires the supply to withstand repeated crowbarring. The rectifying element selected to satisfy these requirements was a commercially-available ignitron, installed in a supporting frame and using firing circuits and controls designed by PPPL

  11. Ultrasound-guided sacroiliac joint injection technique.

    LENUS (Irish Health Repository)

    Harmon, Dominic

    2008-07-01

    We describe a case report and technique for using a portable ultrasound scanner and a curvilinear transducer (4-5MHz) (SonoSite Micromaxx SonoSite, Inc. 21919 30th Drive SE Bothwell W. A.) to guide sacroiliac joint (SIJ) injection. A 42-year-old male presented with chronic lower back pain centered on his left SIJ. His pain averaged 7 out of 10 (numerical rating scale). For the ultrasound-guided SIJ injection the patient was placed in the prone position. The ultrasound transducer was oriented in a transverse orientation at the level of the sacral hiatus. Here the sacral cornuae were identified. Moving the transducer laterally from here, the lateral edge of the sacrum was identified. This bony edge was followed in a cephalad direction with the transducer maintained in a transverse orientation. A second bony contour, the ileum, was identified. The cleft between both bony contours represented the sacroiliac joint. This was found at 4.5 cm depth. Real-time imaging was used to direct a 22G spinal needle into the SIJ, where solution was injected under direct vision. The patient\\'s pain intensity decreased to a 2 out of 10 (numerical rating scale). Function improved and the patient was able to return to work. These improvements were maintained at 16 weeks. Ultrasound guidance does not expose patients and personnel to radiation and is readily accessible. Ultrasound-guided SIJ injections may have particular applications in the management of chronic lower back pain in certain clinical scenarios (e.g. pregnancy). Future studies to demonstrate efficacy and reproducibility are needed.

  12. Injection of pellets into the TCA tokamak

    International Nuclear Information System (INIS)

    Martin, Y.

    1993-05-01

    This thesis presents experimental results from the analysis of the ablation process of pellets injected into the TCA tokamak. The determination of scaling laws relating the pellet penetration to the pellet and plasma parameters preceding injection, were used to improve the understanding of the interaction of the pellet with the plasma since a) the pellet and plasma conditions preceding injection were varied over a large range, and b) the estimation of the penetration depth takes into account the influence of striations in the deposition profile. Over 400 pellets with a range of sizes and speeds were injected into a range of plasma parameters in order to create a database from which the scaling laws could be deduced. The ablation characteristics were principally measured with two CCD video cameras, which provided good spatial resolution, and two filtered photomultiplier tubes, which provided good temporal resolution of the light emitted from the pellet ablation cloud. In the text, the traditional methods of analysing these diagnostics are examined with special reference to the presumptions that a) the pellet velocity is constant in the plasma, and b) the light intensity determined from the ablation cloud is proportional to the ablation rate. After successive data reduction from the database, in order to separate the effects of varying different parameters, the main observations were that, a) the pellet penetration varies as the square root of the pellet velocity, b) the scaling laws for the other parameters strongly depend on whether the pellet has sufficient velocity to reach the q=1 rational magnetic surface in the tokamak. (author) 45 refs

  13. Ocular manifestations of injection drug use.

    Science.gov (United States)

    Kim, Rubin W; Juzych, Mark S; Eliott, Dean

    2002-09-01

    Injection drug use can result in a variety of severe ocular conditions. Hematogenous dissemination of various fungi and bacteria may produce endophthalmitis with resultant severe visual loss. Retinal arterial occlusive disease may result from talc and other particulate emboli. Most commonly, life-threatening systemic diseases such as endocarditis and HIV infection secondarily affect the eye. Because many of these conditions may result in blindness if untreated, accurate diagnosis and prompt initiation of therapy are essential.

  14. EDF plan for a dispersant injection trial

    International Nuclear Information System (INIS)

    Mercier, Stephane; Corredera, Geraldine; Alves-Vieira, Maria; Mansour, Carine; You, Dominique

    2012-09-01

    In its strategy for SG fouling control, EDF is considering the use of dispersant as a preventive remedy. A trial on Golfech 2 started in May 2012. The dispersant selected for the trial is Polyacrylic Acid (PAA). The main goals of the test are to check and quantify the gain on iron transport to blowdown, to evaluate the possible effects on secondary side chemistry and the operational costs of the injection - reactant, ion exchange resins and filters. The results of the test, if satisfying, will be used to set EDF strategy for dispersant long term use on its fleet. So, one concern about the trial is to make sure that the conclusions of this test will be applicable to a wide range of EDF plants. For that purpose, several criteria have been examined for the choice of the candidate plant such as fouling level, secondary circuit materials (presence or absence of copper alloys,...), SG tube material, thermal power margin, secondary side chemistry (amine used and pH applied). Before starting the trial, EDF had to take into account the international feedback and to adapt it to its specific requirements: the neutralization amine was switched from ETA to morpholine, additional work had been completed to validate the innocuousness of PAA injection for EDF plants... This work especially includes laboratory testing of secondary side corrosion cracking in the presence of PAA and water chemistries used in EdF plants. Moreover, investigation on the thermal stability of PAA and degradation products was completed and further evaluation of environmental impact was performed. A dedicated skid for the injection of PAA was implemented in Golfech Chemicals injection room. The installation and the process were notably designed to take into account the high viscosity of the commercial product, and the need to proceed to a good rinsing of the pipes without increasing the discharged effluents. The first available data from Golfech 2 trial are also provided and discussed. (authors)

  15. Durability 2007. Injection grout investigations. Background description

    International Nuclear Information System (INIS)

    Orantie, K.; Kuosa, H.

    2008-12-01

    The aim of this project was to evaluate the durability risks of injection grouts. The investigations were done with respect to the application conditions, materials and service life requirements at the ONKALO underground research facility. The study encompassed injection grout mixtures made of ultrafine cement with and without silica fume. Some of the mixtures hade a low pH and thus a high silica fume content. The project includes a background description on durability literature, laboratory testing programme, detailed analysis of results and recommendations for selecting of ideal grout mixtures. The background description was made for the experimental study of low-pH and reference rock injection grouts as regards pore- and microstructure, strength, shrinkage/swelling and thus versatile durability properties. A summary of test methods is presented as well as examples, i.e. literature information or former test results, of expected range of results from the tests. Also background information about how the test results correlate to other material properties and mix designs is presented. Besides the report provides basic information on the pore structure of cement based materials. Also the correlation between the pore structure of cement based materials and permeability is shortly discussed. The test methods included in the background description are compressive strength, measurement of bulk drying, autogenous and chemical shrinkage and swelling, hydraulic conductivity / permeability, capillary water uptake test, mercury intrusion porosimetry (MIP) and thin section analysis. Three main mixtures with water-binder ratio of 0.8, 1.0 and 1.4 and silica fume content of 0, 15 and 40% were studied in the laboratory. Besides two extra mixtures were studied to provide additional information about the effect of varying water-dry-material ratio and silica fume content on durability. The evaluation of water tightness based on water permeability coefficient and micro cracking was

  16. HIV and Injection Drug Use PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2016-11-29

    This 60 second public service announcement is based on the December 2016 CDC Vital Signs report. Sharing needles, syringes, and other injection equipment puts you at risk for getting HIV and other infections, including hepatitis. Learn how to reduce your HIV risk.  Created: 11/29/2016 by National Center for HIV/AIDS, Viral Hepatitis, Sexual Transmitted Diseases and Tuberculosis Prevention (NCHHSTP).   Date Released: 11/29/2016.

  17. Tennis elbow: role of local steroid injection.

    Science.gov (United States)

    Ahmed, Gulzar Saeed; Ali, Muhammad; Trago, Imtiaz Ahmed

    2012-01-01

    Tennis elbow is a condition, characterised by pain and tenderness over the lateral epicondyle of the humerus, and pain on resisted dorsiflexion of the wrist, middle finger, or both. The aim of this randomised controlled trial was to investigate the short term efficacy of local steroid injection compared with oral and topical NSAIDs. Sixty patients (45 male and 15 female) were included in the study. The mean age was 42 years for men and 40 years for women. They were placed in group A and B (30 cases each). Group A received local steroid injection (triamcinolone 20 mg mixed with lignocaine 2% 1 cc) and topical NSAID cream application (diclofenac diethylammonium) twice a day, tab. diclofenac sodium 50 mg twice a day for 3 weeks. Group B received tab diclofenac 50 mg twice a day and, topical NSAID cream application twice a day for 3 weeks. Assessment of patients was made 3 times; first at the start of the study, 2nd time after 6 weeks, and 3rd time after 12 weeks. A blinded assessor rated the elbow complaints of the patients at resisted dorsiflexion of wrist using VAS (0 = no severity, 1-3 mild, 4-6 moderate, 7-9 sever, 10 = maximum severity). At six weeks, 22 (73.33%) patient in group A had no pain as compared to 7 (23.33%) patients in group B who were pain free (p < 0.0001, chi2 = 38.75). At 12 weeks 27 (90%) patients in group A were pain free compared to group B in which 7 (23.33%) patients were pain free (p < 0.0001, chi2 = 27.56). In patients with tennis elbow, the use of local steroid injection in combination with topical and oral NSAIDs is superior to the use of combination of topical and oral NSAIDs. Better results with combination therapy using local steroid injection may be limited to the short term.

  18. PLT neutral injection ignitron accelerating supply

    International Nuclear Information System (INIS)

    Ashcroft, D.L.; Murray, J.G.; Newman, R.A.; Peterson, F.L.

    1976-03-01

    A phase-controlled rectifier has been designed for the accelerating supply on the PLT Neutral Beam Injection system at PPPL. The rectifier must furnish 70 amperes at up to 50 KV for 300 milliseconds, with a duty cycle of up to 10 percent. Protection of the injectors requires the supply to withstand repeated crowbarring. The rectifying element selected to satisfy these requirements was a commercially-available ignitron, installed in a supporting frame and using firing circuits and controls designed by PPPL

  19. Intravitreal Infliximab Injection to Treat Experimental Endophthalmitis.

    Science.gov (United States)

    Ondas, Osman; Ates, Orhan; Keles, Sadullah; Yildirim, Kenan; Baykal, Orhan; Karamese, Selina Aksak; Karamese, Murat; Uslu, Hakan; Yildirim, Mustafa; Naldan, Muhammet Emin; Ates, Irem

    2017-10-01

    The purpose of this study was to compare the use of an intravitreal injection of infliximab and of dexamethasone combined with vancomycin to treat experimental endophthalmitis induced by Staphylococcus epidermidis. The study was conducted between March 25 and April 13, 2012. Twenty-five six-month-old healthy rabbits were used, each weighing 2.5-3 kg. The rabbits were randomized into five groups with five animals per group. Endophthalmitis was induced by 0.1 mL (103 colony-forming units) S. epidermidis in all groups. In group 1, injection was not implemented after the occurrence of endophthalmitis. In groups 2, 3, and 4, the following intravitreal injections were given 24 h after the occurrence of endophthalmitis: group 2, 0.1 mg/0.1 mL vancomycin; group 3, 1 mg/0.1 mL vancomycin and 1 mg/0.1 mL dexamethasone; and group 4, 1 mg/0.1 mL vancomycin and 2 mg/0.1 mL infliximab. Group 5 was the control/uninfected group. The rabbits were clinically assessed each day for seven days. On day 9, a histopathologic evaluation was performed after enucleation. After a clinical evaluation, no statistically significant difference was found between the vancomycin+infliximab and vancomycin+dexamethasone groups (p>0.05). The difference was significant when both groups were compared with the vancomycin group (p0.05). An intravitreal injection of infliximab and of dexamethasone combined with vancomycin have similar clinical and histopathologic effects. To supplement the antibiotic treatment of endophthalmitis, infliximab in a safe dose range can be used as an alternative to dexamethasone to suppress inflammation and prevent ocular damage.

  20. Injective objects and retracts of Fraisse limits

    Czech Academy of Sciences Publication Activity Database

    Kubiś, Wieslaw

    2015-01-01

    Roč. 27, č. 2 (2015), s. 807-842 ISSN 0933-7741 R&D Projects: GA ČR(CZ) GAP201/12/0290 Institutional support: RVO:67985840 Keywords : amalgamation * Fraissé limit * injective object Subject RIV: BA - General Mathematics Impact factor: 0.823, year: 2015 http://www.degruyter.com/view/j/forum.2015.27.issue-2/forum-2012-0081/forum-2012-0081.xml

  1. Heating of toroidal plasmas by neutral injection

    International Nuclear Information System (INIS)

    Stix, T.H.

    1971-08-01

    This paper presents a brief review of the physics of ion acceleration, charge exchange and ionization, trajectories for fast ions in toroidal magnetic fields, and fast-ion thermalization. The injection of fast atoms is found to be a highly competitive method both for heating present-day experimental toroidal plasmas and for bringing full-scale toroidal CTR plasmas to low-density ignition. 13 refs., 9 figs

  2. Bistability in a laser with injected signal

    International Nuclear Information System (INIS)

    Dorobantu, I.A.; Vlad, V.I.; Ursu, I.

    1987-04-01

    A unified description of bistability is given in free running lasers, optical bistable devices, ring lasers and lasers with an injected signal (LIS). A general review of laser instabilities is also presented in the frame of the theory of elementary catastrophes, emphasizing the apparence of higher order catastrophes in the case of a LIS suggesting thus a possibility to devise from first principles the whole hierarchy of laser instabilities. Experimental results on the bistability in the polarisation of LIS are also discussed. (authors)

  3. Complications of penile self-injections

    DEFF Research Database (Denmark)

    Svensøy, Johannes Nordsteien; Travers, Valentine; Osther, Palle Jörn Sloth

    2018-01-01

    OBJECTIVE: Penile implants and injection of foreign materials have been described in texts like Kama Sutra for more than 1500 years, and are still being practiced around the world. The extent of this practice is unknown, and the documentation available today only scratches the surface. This study...... in the form of radical excision of the lesions followed by skin grafting. Preventive measures to this physically and psychologically devastating problem are highly warranted....

  4. Injective objects and retracts of Fraisse limits

    Czech Academy of Sciences Publication Activity Database

    Kubiś, Wieslaw

    2015-01-01

    Roč. 27, č. 2 (2015), s. 807-842 ISSN 0933-7741 R&D Projects: GA ČR(CZ) GAP201/12/0290 Institutional support: RVO:67985840 Keywords : amalgamation * Fraissé limit * injective object Subject RIV: BA - General Mathematics Impact factor: 0.823, year: 2015 http://www.degruyter.com/view/j/forum.2015.27.issue-2/forum-2012-0081/forum-2012-0081. xml

  5. Working Conditions-Aware Fault Injection Technique

    OpenAIRE

    Alouani , Ihsen; Niar , Smail; Jemai , Mohamed; Kuradi , Fadi; Abid , Mohamed

    2012-01-01

    International audience; With new integration rates, the circuits sensitivity to environmental and working conditions has increased dramatically. Thus, presenting reliable, less consuming energy and error resilient architectures is being one of the major problems to deal with. Besides, evaluating robustness and effectiveness of the proposed architectures is also an urgent need. In this paper, we present an extension of SimpleScalar simulation tool having the ability to inject faults in a given...

  6. Modeling liver electrical conductivity during hypertonic injection.

    Science.gov (United States)

    Castellví, Quim; Sánchez-Velázquez, Patricia; Moll, Xavier; Berjano, Enrique; Andaluz, Anna; Burdío, Fernando; Bijnens, Bart; Ivorra, Antoni

    2018-01-01

    Metastases in the liver frequently grow as scattered tumor nodules that neither can be removed by surgical resection nor focally ablated. Previously, we have proposed a novel technique based on irreversible electroporation that may be able to simultaneously treat all nodules in the liver while sparing healthy tissue. The proposed technique requires increasing the electrical conductivity of healthy liver by injecting a hypersaline solution through the portal vein. Aiming to assess the capability of increasing the global conductivity of the liver by means of hypersaline fluids, here, it is presented a mathematical model that estimates the NaCl distribution within the liver and the resulting conductivity change. The model fuses well-established compartmental pharmacokinetic models of the organ with saline injection models used for resuscitation treatments, and it considers changes in sinusoidal blood viscosity because of the hypertonicity of the solution. Here, it is also described a pilot experimental study in pigs in which different volumes of NaCl 20% (from 100 to 200 mL) were injected through the portal vein at different flow rates (from 53 to 171 mL/minute). The in vivo conductivity results fit those obtained by the model, both quantitatively and qualitatively, being able to predict the maximum conductivity with a 14.6% average relative error. The maximum conductivity value was 0.44 second/m, which corresponds to increasing 4 times the mean basal conductivity (0.11 second/m). The results suggest that the presented model is well suited for predicting on liver conductivity changes during hypertonic saline injection. Copyright © 2017 John Wiley & Sons, Ltd.

  7. Hydrogen pellet injection into Alcator C

    International Nuclear Information System (INIS)

    Greenwald, M.

    1983-09-01

    A four-shot pneumatic pellet injector, based on an ORNL design, has been built and operated on the Alcator C tokamak at MIT. The injector fires four independently-timed frozen hydrogen pellets with velocities in the range 8 x 10 4 - 1 x 10 5 cm/sec. Each contains 6 x 10 19 particles which corresponds to = 2 x 10 14 /cm 3 . The objectives of this experiment are to study pellet fueling and penetration, particle confinement, dependence of energy confinement on density profile and fueling mode, and edge physics and recycling as a function of fueling mode. Typical pre-injection plasmas have had anti n/sub e/ = 2 - 3 x 10 14 , Bt = 80 - 100 kG, Ip = 400 - 500 kA, T/sub e/(0) = 1200 - 1500 ev. A single pellet injected into this plasma will roughly double the electron density. Record plasma densities have been obtained by multiple injections. Line average densities in excess of 8 x 10 14 have been achieved, with highly peaked profiles. Central densities of 1.5 - 2 x 10 15 have been measured

  8. Target injection methods for inertial fusion energy

    International Nuclear Information System (INIS)

    Petzoldt, R.W.; Moir, R.W.

    1994-06-01

    We have studied four methods to inject IFE targets: the gas gun, electrostatic accelerator, induction accelerator, and rail gun. We recommend a gas gun for indirect drive targets because they can support a gas pressure load on one end and can slide along the gun barrel without damage. With the gas gun, the amount of gas required for each target (about 10 to 100 mg) is acceptable; for other types of targets, a sabot would be necessary. A cam and poppet valve arrangement is recommended for gas flow control. An electrostatic accelerator is attractive for use with lightweight spherical direct drive targets. Since there is no physical contact between the target and the injector, there will be no wear of either component during the injection process. An induction accelerator has an advantage of no electrical contact between the target and the injector. Physical contact is not even necessary, so the wear should be minimal. It requires a cylindrical conductive target sleeve which is a substantial added mass. A rail gun is a simpler device than an electrostatic accelerator or induction accelerator. It requires electrical contact between the target and the rails and may have a significant wear rate. The wear in a vacuum could be reduced by use of a solid lubricant such as MoS 2 . The total required accuracy of target injection, tracking and beam pointing of ±0.4 mm appears achievable but will require development and experimental verification

  9. Tomography at Injection in the PSB

    CERN Document Server

    Hancock, Steven

    2016-01-01

    The PSB was conceived as an intensity booster for fixed-target physics. Consequently, no attempt was ever made to synchronize the turns injected into each ring with the rf in that ring because as many as a dozen such turns were expected to be superposed longitudinally [1]. When only a small, non-integer number of turns is injected, this asynchronism results in a particle distribution whose initial phase fluctuates wildly from shot to shot with respect to the rf bucket into which it is subsequently captured. This has long been suspected to be an ingredient in the intensity non-reproducibility observed for low-intensity beams, such as pilot beams for the LHC [2]. An MD cycle has been built to pursue this suspicion (in one ring, at least) by introducing, in a fully ppm fashion, distributor timings that are first resynchronized to the rf train of Ring3 and that then count 40 MHz clock ticks to reduce any jitter to just 25 ns (cf., the bucket duration at Booster injection is 1.67 μs). Leaving aside the origin...

  10. Relative injectivity and CS-modules

    Directory of Open Access Journals (Sweden)

    Mahmoud Ahmed Kamal

    1994-01-01

    Full Text Available In this paper we show that a direct decomposition of modules M⊕N, with N homologically independent to the injective hull of M, is a CS-module if and only if N is injective relative to M and both of M and N are CS-modules. As an application, we prove that a direct sum of a non-singular semisimple module and a quasi-continuous module with zero socle is quasi-continuous. This result is known for quasi-injective modules. But when we confine ourselves to CS-modules we need no conditions on their socles. Then we investigate direct sums of CS-modules which are pairwise relatively inective. We show that every finite direct sum of such modules is a CS-module. This result is known for quasi-continuous modules. For the case of infinite direct sums, one has to add an extra condition. Finally, we briefly discuss modules in which every two direct summands are relatively inective.

  11. Massive Cerebral Infarction Following Facial Fat Injection.

    Science.gov (United States)

    Shen, Xiao; Li, Qi; Zhang, Hengshu

    2016-10-01

    Autologous facial fat injection is becoming popular around the world. Semiliquid fat grafts are used for correction of deformities or aesthetic purposes. Fat transfer is a mini-invasive surgical procedure, but causes severe complications occasionally. A 30-year-old female patient presented to our hospital with sudden unconsciousness and left limb weakness 8 h after facial fat injection. Brain arteriography (CTA) and venography were performed immediately after her admission. Frontal temporoparietal decompressive craniectomy plus multiple treatments was scheduled for the patient. The patient was diagnosed with extensive cerebral infarction of the right hemisphere. CTA showed that both external and internal carotid arteries were obstructed. A sectional filling defect could be seen at the telecentric segment of the right carotid artery. No development was observed during the full course of the treatment at the carotid bifurcation, external carotid artery, or internal carotid artery. Routine cosmetic procedures of facial fat injections could cause devastating and even fatal complications to patients. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the A5 online Instructions to Authors www.springer.com/00266.

  12. The ''injection problem'' for quasiparallel shocks

    International Nuclear Information System (INIS)

    Zank, G. P.; Rice, W. K. M.; le Roux, J. A.; Cairns, I. H.; Webb, G. M.

    2001-01-01

    For a particle to be accelerated diffusively at a shock by the first-order Fermi acceleration mechanism, the particle must be sufficiently energetic that it can scatter across all the micro- and macrostructure of the shock, experiencing compression between the converging upstream and downstream states. This is the well-known ''injection problem.'' Here the interaction of ions with the ramp of a quasiparallel shock is investigated. Some ions incident on the shock experience specular reflection, caused either by the cross-shock electrostatic potential or by mirroring as the magnetic field is bent and compressed through the ramp. Scattering of reflected ions by self-generated and pre-existing turbulence in the region upstream of the shock then acts to trap backstreaming ions and return them to the ramp, where some experience further reflections. Such repeated reflections and scattering energize a subpopulation of ions up to energies sufficiently large that they can be diffusively shock accelerated. Two ion distributions are considered: pickup ions which are assumed to be described by a shell distribution, are thermal solar wind ions which may be described by a kappa distribution. Injection efficiencies are found analytically to be very high for pickup ions and much lower for thermal solar wind ions, suggesting that this injection mechanism, stochastic reflected ion or SRI acceleration, is a natural precursor for the acceleration of the anomalous cosmic ray component at a quasiparallel shock. While significantly less efficient, SRI acceleration is also viable for thermal solar wind ions described by a kappa distribution

  13. The Advanced Photon Source injection timing system

    International Nuclear Information System (INIS)

    Lenkszus, F.R.; Laird, R.

    1995-01-01

    The Advanced Photon Source consists of five accelerators. The injection timing system provides the signals required to cause a bunch emitted from the electron gun to navigate through intermediate accelerators to a specific bucket (1 out of 1296) within the storage ring. Two linacs and a positron accumulator ring operate at 60Hz while a booster synchrotron ramps and injects into the storage ring at 2Hz. The distributed, modular VME/VXI-based injection timing system is controlled by two EPICS-based input/output controllers (IOCs). Over 40 VME/VXI cards have been developed to implement the system. Card types range from 352MHz VXI timing modules to VME-based fiber optic fanouts and logic translators/drivers. All timing is distributed with fiber optics. Timing references are derived directly from machine low-level rf of 9.77MHz and 352MHz. The timing references provide triggers to programmable delay generators. Three grades of timing are provided. Precision timing is derived from commercial digital delay generators, intermediate precision timing is obtained from VXI 8-channel digital delay generators which provide timing with 25ns peak-to-peak jitter, and modest precision timing is provided by the APS event system. The timing system is fully integrated into the APS EPICS-based control system

  14. Turbulent shear control with oscillatory bubble injection

    International Nuclear Information System (INIS)

    Park, Hyun Jin; Oishi, Yoshihiko; Tasaka, Yuji; Murai, Yuichi; Takeda, Yasushi

    2009-01-01

    It is known that injecting bubbles into shear flow can reduce the frictional drag. This method has advantages in comparison to others in simplicity of installation and also in environment. The amount of drag reduction by bubbles depends on the void fraction provided in the boundary layer. It means, however, that certain power must be consumed to generate bubbles in water, worsening the total power-saving performance. We propose oscillatory bubble injection technique to improve the performance in this study. In order to prove this idea of new type of drag reduction, velocity vector field and shear stress profile in a horizontal channel flow are measured by ultrasonic velocity profiler (UVP) and shear stress transducer, respectively. We measure the gas-liquid interface from the UVP signal, as well. This compound measurement with different principles leads to deeper understanding of bubble-originated drag reduction phenomena, in particular for unsteady process of boundary layer alternation. At these experiments, the results have demonstrated that the intermittency promotes the drag reduction more than normal continuous injection for the same void fraction supplied.

  15. Jet noise reduction via dispersed phase injection

    Science.gov (United States)

    Greska, Brent; Krothapalli, Anjaneyulu; Arakeri, Vijay

    2001-11-01

    A recently developed hot jet aeroacoustics facility at FMRL,FAMU-FSU College of Engineering has been used to study the far field noise characteristics of hot supersonic jets as influenced by the injection of a dispersed phase with low mass loading.The measured SPL from a fully expanded Mach 1.36 hot jet shows a peak value of about 139 dB at 40 deg from the jet axis.By injecting atomized water,the SPL are reduced in the angular region of about 30 deg to 50 deg with the maximum reduction being about 2 dB at 40 deg.However,with the use of non atomized aqueous polymer solution as a dispersed phase the noise levels are reduced over all angular positions by at least 1 dB with the maximum reduction being about 3 dB at 40 deg.The injection of a dispersed phase readily kills the screech; the initial results show promise and optimization studies are underway to find methods of further noise reduction.

  16. PEP-II injection timing and controls

    International Nuclear Information System (INIS)

    Bharadwaj, V.; Browne, M.; Crane, M.; Gromme, T.; Himel, T.; Ross, M.; Stanek, M.; Ronan, M.

    1997-07-01

    Hardware has been built and software written and incorporated in the existing SLC accelerator control system to control injection of beam pulses from the accelerator into the PEP-II storage rings currently under construction. Hardware includes a CAMAC module to delay the machine timing fiducial in order that a beam pulse extracted from a damping ring will be injected into a selected group of four 476 MHz buckets in a PEP-II ring. Further timing control is accomplished by shifting the phase of the bunches stored in the damping rings before extraction while leaving the phase of the PEP-II stored beam unchanged. The software which drives timing devices on a pulse-to-pulse basis relies on a dedicated communication link on which one scheduling microprocessor broadcasts a 128-bit message to all distributed control microprocessors at 360 Hz. PEP-II injection will be driven by the scheduling microprocessor according to lists specifying bucket numbers in arbitrary order, and according to scheduling constraints maximizing the useful beam delivered to the SLC collider currently in operation. These lists will be generated by a microprocessor monitoring the current stored per bucket in each of the PEP-II rings

  17. Resilient children of injection drug users.

    Science.gov (United States)

    Pilowsky, Daniel J; Zybert, Patricia A; Vlahov, David

    2004-11-01

    To examine associations between resilience in children of injection drug users and children's coping strategies, parenting stress, and children's social support. Injection drug-using parents (n=91) and their children aged 6 to 11 (n=117) were recruited in Baltimore (1997-1999). Resilience was defined as scoring in the lowest quartile of the Child Behavior Checklist total psychopathology score. Coping strategies used by resilient and nonresilient children, the extent and types of social support that they received, and the level of parenting stress reported by their parents were compared and contrasted. Rates of depressive, anxiety, and disruptive behavior disorders were 15.4%, 22.2%, and 21.4%, respectively, for the entire sample. Compared with the nonresilient, resilient children were less likely to use two avoidance coping strategies (internalizing [p=.002] and externalizing [p=.017]). The level of actual support received by resilient and nonresilient children did not differ significantly (p=.202). Perceived support was greater among resilient children (as reported by their parents; p parents reported lower parenting stress (p=.042). A significant proportion of children of injection drug users are in need of clinical care. Interventions to help children of substance-abusing parents modify their coping style merit exploration.

  18. Allergic anaphylaxis due to subcutaneously injected heparin

    Directory of Open Access Journals (Sweden)

    Anders Diana

    2013-01-01

    Full Text Available Abstract Heparins are one of the most used class of anticoagulants in daily clinical practice. Despite their widespread application immune-mediated hypersensitivity reactions to heparins are rare. Among these, the delayed-type reactions to s.c. injected heparins are well-known usually presenting as circumscribed eczematous plaques at the injection sites. In contrast, potentially life-threatening systemic immediate-type anaphylactic reactions to heparins are extremely rare. Recently, some cases of non-allergic anaphylaxis could be attributed to undesirable heparin contaminants. A 43-year-old patient developed severe anaphylaxis symptoms within 5–10 minutes after s.c. injection of enoxaparin. Titrated skin prick testing with wheal and flare responses up to an enoxaparin dilution of 1:10.000 indicated a probable allergic mechanism of the enoxaparin-induced anaphylaxis. The basophil activation test as an additional in-vitro test method was negative. Furthermore, skin prick testing showed rather broad cross-reactivity among different heparin preparations tested. In the presented case, history, symptoms, and results of skin testing strongly suggested an IgE-mediated allergic hypersensitivity against different heparins. Therefore, as safe alternative anticoagulants the patient could receive beneath coumarins the hirudins or direct thrombin inhibitors. Because these compounds have a completely different molecular structure compared with the heparin-polysaccharides.

  19. Effect of the Ethanol Injection Moment During Compression Stroke on the Combustion of Ethanol - Diesel Dual Direct Injection Engine

    Science.gov (United States)

    Liang, Yu; Zhou, Liying; Huang, Haomin; Xu, Mingfei; Guo, Mei; Chen, Xin

    2018-01-01

    A set of GDI system is installed on a F188 single-cylinder, air-cooled and direct injection diesel engine, which is used for ethanol injection, with the injection time controlled by the crank angle signal collected by AVL angle encoder. The injection of ethanol amounts to half of the thermal equivalent of an original diesel fuel. A 3D combustion model is established for the ethanol - diesel dual direct injection engine. Diesel was injected from the original fuel injection system, with a fuel supply advance angle of 20°CA. The ethanol was injected into the cylinder during compression process. Diesel injection began after the completion of ethanol injection. Ethanol injection starting point of 240°CA, 260°CA, 280°CA, 300°CA and 319.4°CA were simulated and analyzed. Due to the different timing of ethanol injection, the ignition of the ethanol mixture when diesel fires, results in non-uniform ignition distribution and flame propagation rate, since the distribution and concentration gradients of the ethanol mixture in the cylinder are different, thus affecting the combustion process. The results show that, when ethanol is injected at 319.4°CA, the combustion heat release rate and the pressure rise rate during the initial stage are the highest. Also, the maximum combustion pressure, with a relatively advance phase, is the highest. In case of later initial ethanol injection, the average temperature in the cylinder during the initial combustion period will have a faster rise. In case of initial injection at 319.4°CA, the average temperature in the cylinder is the highest, followed by 240°CA ethanol injection. In the post-combustion stage, the earlier ethanol injection will result in higher average temperature in the cylinder and more complete fuel combustion. The injection of ethanol at 319.4°CA produces earlier and highest NOX emissions.

  20. Sonographically guided deep plantar fascia injections: where does the injectate go?

    Science.gov (United States)

    Maida, Eugene; Presley, James C; Murthy, Naveen; Pawlina, Wojciech; Smith, Jay

    2013-08-01

    To determine the distribution of sonographically guided deep plantar fascia injections in an unembalmed cadaveric model. A single experienced operator completed 10 sonographically guided deep plantar fascia injections in 10 unembalmed cadaveric specimens (5 right and 5 left) obtained from 6 donors (2 male and 4 female) aged 49 to 95 years (mean, 77.5 years) with a mean body mass index of 23.2 kg/m(2) (range, 18.4-26.3 kg/m(2)). A 12-3-MHz linear array transducer was used to direct a 22-gauge, 38-mm stainless steel needle deep to the plantar fascia at the anterior aspect of the calcaneus using an in-plane, medial-to-lateral approach. In each case, 1.5 mL of 50% diluted colored latex was injected deep to the plantar fascia. After a minimum of 72 hours, study coinvestigators dissected each specimen to assess injectate placement. All 10 injections accurately placed latex adjacent to the deep side of the plantar fascia at the anterior calcaneus. However, the flexor digitorum brevis (FDB) origin from the plantar fascia variably limited direct latex contact with the plantar fascia, and small amounts of latex interdigitated with the FDB origin in 90% (9 of 10). In all 10 specimens, latex also covered the traversing first branch of the lateral plantar nerve (FBLPN, ie, Baxter nerve) between the FDB and quadratus plantae muscles. No latex was found in the plantar fat pad or plantar fascia in any specimen. Sonographically guided deep plantar fascia injections reliably deliver latex deep to the plantar fascia while avoiding intrafascial injection. However, the extent of direct plantar fascia contact is variable due to the intervening FDB. On the contrary, the traversing FBLPN is reliably covered by the injection. Deep plantar fascia injections may have a role in the management of refractory plantar fasciitis, particularly following failed superficial perifascial or intrafascial injections, in cases of preferential deep plantar fascia involvement, or when entrapment

  1. Effects of hypertonic dextrose injections in the rabbit carpal tunnel.

    Science.gov (United States)

    Yoshii, Yuichi; Zhao, Chunfeng; Schmelzer, James D; Low, Phillip A; An, Kai-Nan; Amadio, Peter C

    2011-07-01

    This study investigated the effects of different doses of hypertonic dextrose injection on the carpal tunnel subsynovial connective tissue (SSCT) and median nerve in a rabbit model. Thirty-eight New Zealand white rabbits weighing 4.0-4.5 kg were used. One forepaw carpal tunnel was randomly injected with one of five different treatments: saline-single injection; saline-two injections 1 week apart; 10% dextrose-single injection; 20% dextrose-single injection; or 10% dextrose-two injections 1 week apart. Animals were sacrificed at 12 weeks after the initial injection and were evaluated by electrophysiology (EP), SSCT mechanical testing and histology. There were significant increases in the energy absorption of the SSCT in the 10% dextrose-double injection group compared to the saline injection groups. SSCT stiffness was also significantly increased in the 10% dextrose-double injection group compared to the other groups. There was a significant increase in the thickness of the SSCT in the 10% dextrose-double injection group compared to the saline-single injection group and a significant decrease in the nerve short-long diameter ratio in the 10% dextrose-double injection group compared to the saline-single injection group. There were no changes in EP among the groups. SSCT fibrosis is present for up to 12 weeks after dextrose injection; multiple injections have bigger effects, including what appears to be a secondary change in nerve flattening. This model may be useful to study the effects of external fibrosis on nerve morphology and physiology, such as occurs clinically in carpal tunnel syndrome. Copyright © 2011 Orthopaedic Research Society.

  2. Strategies and challenges for safe injection practice in developing countries.

    Science.gov (United States)

    Gyawali, Sudesh; Rathore, Devendra Singh; Shankar, P Ravi; Kumar, Kc Vikash

    2013-01-01

    Injection is one of the important health care procedures used globally to administer drugs. Its unsafe use can transmit various blood borne pathogens. This article aims to review the history and status of injection practices, its importance, interventions and the challenges for safe injection practice in developing countries. The history of injections started with the discovery of syringe in the early nineteenth century. Safe injection practice in developed countries was initiated in the early twentieth century but has not received adequate attention in developing countries. The establishment of "Safe Injection Global Network (SIGN)" was an milestone towards safe injection practice globally. In developing countries, people perceive injection as a powerful healing tool and do not hesitate to pay more for injections. Unsafe disposal and reuse of contaminated syringe is common. Ensuring safe injection practice is one of the greatest challenges for healthcare system in developing countries. To address the problem, interventions with active involvement of a number of stakeholders is essential. A combination of educational, managerial and regulatory strategies is found to be effective and economically viable. Rational and safe use of injections can save many lives but unsafe practice threatens life. Safe injection practice is crucial in developing countries. Evidence based interventions, with honest commitment and participation from the service provider, recipient and community with aid of policy makers are required to ensure safe injection practice.

  3. Surgical versus injection treatment for injection-confirmed chronic sacroiliac joint pain

    Science.gov (United States)

    Spiker, William Ryan; Lawrence, Brandon D.; Raich, Annie L.; Skelly, Andrea C.; Brodke, Darrel S.

    2012-01-01

    Study design: Systematic review. Study rationale: Chronic sacroiliac joint pain (CSJP) is a common clinical entity with highly controversial treatment options. A recent systematic review compared surgery with denervation, but the current systematic review compares outcomes of surgical intervention with therapeutic injection for the treatment of CSJP and serves as the next step for evaluating current evidence on the comparative effectiveness of treatments for non-traumatic sacroiliac joint pain. Objective or clinical question: In adult patients with injection-confirmed CSJP, does surgical treatment lead to better outcomes and fewer complications than injection therapy? Methods: A systematic review of the English-language literature was undertaken for articles published between 1970 and June 2012. Electronic databases and reference lists of key articles were searched to identify studies evaluating surgery or injection treatment for injection-confirmed CSJP. Studies involving traumatic onset or non-injection–confirmed CSJP were excluded. Two independent reviewers assessed the level of evidence quality using the grading of recommendations assessment, development and evaluation (GRADE) system, and disagreements were resolved by consensus. Results: We identified twelve articles (seven surgical and five injection treatment) meeting our inclusion criteria. Regardless of the type of treatment, most studies reported over 40% improvement in pain as measured by Visual Analog Scale or Numeric rating Scale score. Regardless of the type of treatment, most studies reported over 20% improvement in functionality. Most complications were reported in the surgical studies. Conclusion: Surgical fusion and therapeutic injections can likely provide pain relief, improve quality of life, and improve work status. The comparative effectiveness of these interventions cannot be evaluated with the current literature. PMID:23526911

  4. 21 CFR 522.468 - Colistimethate sodium powder for injection.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW... injection in the neck of 1- to 3-day-old chickens. Not for use in laying hens producing eggs for human...

  5. Corticosteroid injections for lateral epicondylitis: a systematic review.

    NARCIS (Netherlands)

    Smidt, Nynke; Assendelft, Willem J J; van der Windt, Danielle A W M; Hay, Elaine M; Buchbinder, Rachelle; Bouter, Lex M

    Patients with lateral epicondylitis (tennis elbow) are frequently treated with corticosteroid injections, in order to relieve pain and diminish disability. The objective of this review was to evaluate the effectiveness of corticosteroid injections for lateral epicondylitis. Randomised controlled

  6. Wrist arthrography: The value of the three compartment injection technique

    Energy Technology Data Exchange (ETDEWEB)

    Levinsohn, E.M.; Coren, A.B.; Palmer, A.K.; Zinberg, E.

    1987-10-01

    Arthrography of the wrist was performed on 50 consecutive patients with obscure post-traumatic wrist pain by injecting contrast separately into the radiocarpal joint, midcarpal compartment, and distal radioulnar joint. When distal radioulnar joint and midcarpal compartment injections were added to the standard radiocarpal injection, many significant unsuspected abnormalities were identified. Of the 25 triangular fibrocartilage complex abnormalities identified, six (24%) were found only with the distal radioulnar joint injection. Of the 29 abnormal communications between the midcarpal compartment and the radiocarpal joint, ten (35%) were found only with the midcarpal injection. Similarly, five of 29 (17%) of the abnormal radiocarpal-midcarpal communications would have been missed if a midcarpal injection alone had been performed. These findings indicate that separate injections into the radiocarpal joint, midcarpal compartment, and distal radioulnar joint are needed to identify a large number of abnormalities not seen with injections into one compartment alone.

  7. Near-surface groundwater responses to injection of geothermal wastes

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, S.C.

    1984-06-01

    Experiences with injecting geothermal fluids have identified technical problems associated with geothermal waste disposal. This report assesses the feasibility of injection as an alternative for geothermal wastewater disposal and analyzes hydrologic controls governing the upward migration of injected fluids. Injection experiences at several geothermal developments are presented, including: Raft River, Salton Sea, East Mesa, Otake and Hatchobaru in Japan, and Ahuachapan in El Salvador. Hydrogeologic and design/operational factors affecting the success of an injection program are identified. Hydrogeologic factors include subsidence, near-surface effects of injected fluids, and seismicity. Design/operational factors include hydrodynamic breakthrough, condition of the injection system and reservoir maintenance. Existing and potential effects of production/injection on these factors are assessed.

  8. Characteristics of pressure wave in common rail fuel injection system of high-speed direct injection diesel engines

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Herfatmanesh

    2016-05-01

    Full Text Available The latest generation of high-pressure common rail equipment now provides diesel engines possibility to apply as many as eight separate injection pulses within the engine cycle for reducing emissions and for smoothing combustion. With these complicated injection arrangements, optimizations of operating parameters for various driving conditions are considerably difficult, particularly when integrating fuel injection parameters with other operating parameters such as exhaust gas recirculation rate and boost pressure together for evaluating calibration results. Understanding the detailed effects of fuel injection parameters upon combustion characteristics and emission formation is therefore particularly critical. In this article, the results and discussion of experimental investigations on a high-speed direct injection light-duty diesel engine test bed are presented for evaluating and analyzing the effects of main adjustable parameters of the fuel injection system on all regulated emission gases and torque performance. Main injection timing, rail pressure, pilot amount, and particularly pilot timing have been examined. The results show that optimization of each of those adjustable parameters is beneficial for emission reduction and torque improvement under different operating conditions. By exploring the variation in the interval between the pilot injection and the main injection, it is found that the pressure wave in the common rail has a significant influence on the subsequent injection. This suggests that special attentions must be paid for adjusting pilot timing or any injection interval when multi-injection is used. With analyzing the fuel amount oscillation of the subsequent injections to pilot separation, it demonstrates that the frequency of regular oscillations of the actual fuel amount or the injection pulse width with the variation in pilot separation is always the same for a specified fuel injection system, regardless of engine speed

  9. Survey of Botulinum Toxin Injections in Anticoagulated Patients: Korean Physiatrists' Preference in Controlling Anticoagulation Profile Prior to Intramuscular Injection.

    Science.gov (United States)

    Jang, Yongjun; Park, Geun-Young; Park, Jihye; Choi, Asayeon; Kim, Soo Yeon; Boulias, Chris; Phadke, Chetan P; Ismail, Farooq; Im, Sun

    2016-04-01

    To evaluate Korean physiatrists' practice of performing intramuscular botulinum toxin injection in anticoagulated patients and to assess their preference in controlling the bleeding risk before injection. As part of an international collaboration survey study, a questionnaire survey was administered to 100 Korean physiatrists. Physiatrists were asked about their level of experience with botulinum toxin injection, the safe international normalized ratio range in anticoagulated patients undergoing injection, their tendency for injecting into deep muscles, and their experience of bleeding complications. International normalized ratio injection by 41% of the respondents. Thirty-six respondents replied that the international normalized ratio should be lowered to sub-therapeutic levels before injection, and 18% of the respondents reported that anticoagulants should be intentionally withheld and discontinued prior to injection. In addition, 20%-30% of the respondents answered that they were uncertain whether they should perform the injection regardless of the international normalized ratio values. About 69% of the respondents replied that they did have any standardized protocols for performing botulinum toxin injection in patients using anticoagulants. Only 1 physiatrist replied that he had encountered a case of compartment syndrome. In accordance with the lack of consensus in performing intramuscular botulinum toxin injection in anticoagulated patients, our survey shows a wide range of practices among many Korean physiatrists; they tend to avoid botulinum toxin injection in anticoagulated patients and are uncertain about how to approach these patients. The results of this study emphasize the need for formulating a proper international consensus on botulinum toxin injection management in anticoagulated patients.

  10. Two injection digital block versus single subcutaneous palmar injection block for finger lacerations.

    Science.gov (United States)

    Okur, O M; Şener, A; Kavakli, H Ş; Çelik, G K; Doğan, N Ö; Içme, F; Günaydin, G P

    2017-12-01

    We aimed to compare two digital nerve block techniques in patients due to traumatic digital lacerations. This was a randomized-controlled study designed prospectively in the emergency department of a university-based training and research hospital. Randomization was achieved by sealed envelopes. Half of the patients were randomised to traditional (two-injection) digital nerve block technique while single-injection digital nerve block technique was applied to the other half. Score of pain due to anesthetic infiltration and suturing, onset time of total anesthesia, need for an additional rescue injection were the parameters evaluated with both groups. Epinephrin added lidocaine hydrochloride preparation was used for the anesthetic application. Visual analog scale was used for the evaluation of pain scores. Outcomes were compared by using Mann-Whitney U test and Student t-test. Fifty emergency department patients ≥18 years requiring digital nerve block were enrolled in the study. Mean age of the patients was 33 (min-max: 19-86) and 39 (78 %) were male. No statistically significant difference was found between the two groups in terms of our main parameters; anesthesia pain score, suturing pain score, onset time of total anesthesia and rescue injection need. Single injection volar digital nerve block technique is a suitable alternative for digital anesthesias in emergency departments.

  11. Trapping of gun-injected plasma by a tokamak

    International Nuclear Information System (INIS)

    Leonard, A.W.; Dexter, R.N.; Sprott, J.C.

    1986-01-01

    It is shown that a plasma produced by a Marshall gun can be injected into and trapped by a tokamak plasma. Gun injection raises the line-averaged density and peaks the density profile. Trapping of the gun-injected plasma is explainable in terms of a depolarization current mechanism

  12. 21 CFR 522.800 - Droperidol and fentanyl citrate injection.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Droperidol and fentanyl citrate injection. 522.800... § 522.800 Droperidol and fentanyl citrate injection. (a) Specifications. Droperidol and fentanyl citrate injection is a sterile solution containing 20 milligrams of droperidol and 0.4 milligram of fentanyl citrate...

  13. Influence of vitamin b-12 complex injection (eldervit-12) on ...

    African Journals Online (AJOL)

    Objectives: To assess the effect of vitamin B-12 complex injection on the nephrotoxicity of gentamicin. Design: Experimental study using a pre-validated model. Subject: Adult Swiss albino rats weighing 140-214g, Generic gentamicin sulphate injection and Vitamin B-12complex injection containing 2500mcg ...

  14. COMBUSTION ANALYSIS OF A CNG DIRECT INJECTION SPARK IGNITION ENGINE

    Directory of Open Access Journals (Sweden)

    A. Rashid A. Aziz

    2010-12-01

    Full Text Available An experimental study was carried out on a dedicated compressed natural gas direct injection (CNG-DI engine with a compression ratio (CR of 14 and a central injection system. Several injection timing parameters from early injection timing (300 BTDC to partial direct injection (180 BTDC to full direct injection (120 BTDC were investigated. The 300 BTDC injection timing experiment was carried out to simulate the performance of a port injection engine and the result is used as a benchmark for engine performance. The full DI resulted in a 20% higher performance than the early injection timing for low engine speeds up to 2750 rpm. 180 BTDC injection timing shows the highest performance over an extensive range of engine speed because it has a similar volumetric efficiency to full DI. However, the earlier injection timing allowed for a better air–fuel mixing and gives superior performance for engine speeds above 4500 rpm. The engine performance could be explained by analysis of the heat release rate that shows that at low and intermediate engine speeds of 2000 and 3000, the full DI and partial DI resulted in the fastest heat release rate whereas at a high engine speed of 5000 rpm, the simulated port injection operation resulted in the fastest heat release rate.

  15. Challenges to Safe Injection Practices in Ambulatory Care.

    Science.gov (United States)

    Anderson, Laura; Weissburg, Benjamin; Rogers, Kelli; Musuuza, Jackson; Safdar, Nasia; Shirley, Daniel

    2017-05-01

    Most recent infection outbreaks caused by unsafe injection practices in the United States have occurred in ambulatory settings. We utilized direct observation and a survey to assess injection practices at 31 clinics. Improper vial use was observed at 13 clinics (41.9%). Pharmacy support and healthcare worker education may improve injection practices. Infect Control Hosp Epidemiol 2017;38:614-616.

  16. A protocol for the retina surgeon's safe initial intravitreal injections.

    Science.gov (United States)

    Frenkel, Ronald E P; Haji, Shamim A; La, Melvin; Frenkel, Max P C; Reyes, Angela

    2010-11-10

    To determine the safety of a surgeon's initial consecutive intravitreal injections using a specific protocol and to review the complications that may be attributed to the injection procedure. A retrospective chart review. Fifty-nine patients (30 females, 29 males) received intravitreal injections of pegaptanib, bevacizumab, or ranibizumab as part of their treatment for neovascular age-related macular degeneration. The average patient age was 80 years. Twenty-two patients were diagnosed with or suspected of having glaucoma. Each patient received an average of 5.8 injections. The charts of 59 patients who received a total of 345 intravitreal injections (104 pegaptanib, 74 bevacizumab, 167 ranibizumab) were reviewed. All injections were performed in an office-based setting. Povidone-iodine, topical antibiotics, and eye speculum were used as part of the pre injection procedure. Vision and intraocular pressure were evaluated immediately following each injection. Incidence of post injection complications, including but not limited to endophthalmitis, retinal detachment, traumatic cataract, and vitreous hemorrhage. There were no cases of endophthalmitis, toxic reactions, traumatic cataracts, retinal detachment, or vitreous hemorrhage. There was one case each of lid swelling, transient floaters, retinal pigment epithelial tear, corneal edema, and corneal abrasion. There were five cases of transient no light perception following pegaptanib injections. The incidence of serious complications was very low for the intravitreal injections given. A surgeon's initial intravitreal injections may be performed with a very high degree of safety using this protocol.

  17. Performance of injection-limited polymer light-emitting diodes

    NARCIS (Netherlands)

    Blom, P.W.M.; Woudenberg, T.V.; Huiberts, H.; Jabbour, GE; Carter, SA; Kido, J; Lee, ST; Sariciftci, NS

    2002-01-01

    The electro-optical characteristics of a polymer light emitting diode (PLED) with a strongly reduced hole injection have been investigated. The device consists of a poly-p-phenylene vinylene semiconductor with a Ag hole injecting contact, which has an injection barrier of about 1 eV. It is observed

  18. Near-surface groundwater responses to injection of geothermal wastes

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, S.C.

    1984-06-01

    This report assesses the feasibility of injection as an alternative for geothermal wastewater disposal and analyzes hydrologic controls governing the upward migration of injected fluids. Injection experiences at several geothermal developments are presented including the following: Raft River Valley, Salton Sea, East Mesa, Otake, Hatchobaru, and Ahuachapan geothermal fields.

  19. Injection related anxiety in insulin-treated diabetes.

    Science.gov (United States)

    Zambanini, A; Newson, R B; Maisey, M; Feher, M D

    1999-12-01

    The presence of injection related anxiety and phobia may influence compliance, glycaemic control and quality of life in patients with insulin-treated diabetes. Unselected consecutive, insulin-treated patients attending a diabetes clinic for follow-up, completed a standardised questionnaire providing an injection anxiety score (IAS) and general anxiety score (GAS). A total of 115 insulin-treated (80 Type 1 and 35 Type 2) diabetic patients completed the questionnaire. Injections had been avoided secondary to anxiety in 14% of cases and 42% expressed concern at having to inject more frequently. An IAS > or = 3 was seen in 28% of patients and of these, 66% injected insulin one to two times/day, 45% had avoided injections, and 70% would be bothered by more frequent injections. A significant correlation between IAS and GAS was seen (Kendall's tau-a 0.30, 95% CI 0.19-0.41, P < 0.001). GAS was significantly associated with both previous injection avoidance and expressed concern at increased injection frequency. No significant correlation was seen with HbA1c and injection or general anxiety scores. Symptoms relating to insulin injection anxiety and phobia have a high prevalence in an unselected group of diabetic patients requiring insulin injections and are associated with higher levels of general anxiety.

  20. Injection system of the minicyclotron accelerator mass spectrometer

    International Nuclear Information System (INIS)

    Liu Yonghao; Li Deming; Chen Maobai; Lu Xiangshun

    1999-01-01

    The existing injection system of the SMCAMS (super-sensitive mini-cyclotron accelerator mass spectrometer) is described together with the discussion of its disadvantages exposed after having been operating for five years, which provides a basis for consideration of improvements to the injection system. An optimized injection system with an analytical magnet added prior to the minicyclotron has been proposed and calculated

  1. Class I Underground Injection Control Program: Study of the Risks Associated with Class I Underground Injection Wells

    Science.gov (United States)

    The document provides describes the current Class I UIC program, the history of Class I injection, and studies of human health risks associated with Class I injection wells, which were conducted for past regulatory efforts and policy documentation.

  2. Impact of physical properties of biodiesel on the injection process in a common-rail direct injection system

    International Nuclear Information System (INIS)

    Boudy, Frederic; Seers, Patrice

    2009-01-01

    This paper presents the influence of biodiesel fuel properties on the injection mass flow rate of a diesel common-rail injection system. Simulations are first performed with ISO 4113 diesel fuel on a four-cylinder common-rail system to evaluate a single and triple injection strategies. For each injection strategy, the impact of modifying a single fuel property at a time is evaluated so as to quantify its influence on the injection process. The results show that fuel density is the main property that affects the injection process, such as total mass injected and pressure wave in the common-rail system. The fuel's viscosity and bulk modulus also influence, but to a lessen degree, the mass flow rate of the injector notably during multiple injection strategies as individual properties change the fuel's dampening property and friction coefficient.

  3. Cost-Utility of a Single-Injection Combined Corticosteroid-Hyaluronic Acid Formulation vs a 2-Injection Regimen of Sequential Corticosteroid and Hyaluronic Acid Injections.

    Science.gov (United States)

    Belzile, Etienne L; Deakon, Robert T; Vannabouathong, Christopher; Bhandari, Mohit; Lamontagne, Martin; McCormack, Robert

    2017-01-01

    Research has shown early and sustained relief with a combination therapy of a corticosteroid (CS) and hyaluronic acid (HA) in knee osteoarthritis (OA) patients. This can be administered via a single injection containing both products or as separate injections. The former may be more expensive when considering only product cost, but the latter incurs the additional costs and time of a second procedure. The purpose of this study was to compare the cost-utility of the single injection with the 2-injection regimen. The results of this analysis revealed that the single-injection formulation of a CS and HA may be cost-effective, assuming a willingness-to-pay of $50 000 per quality-adjusted life year gained, for symptomatic relief of OA symptoms. This treatment may also be more desirable to patients who find injections to be inconvenient or unpleasant.

  4. Particle balance studies in TEXTOR during experiments of pellet injection, helium injection, and ICR-heating

    International Nuclear Information System (INIS)

    Banno, T.; Finken, K.H.; Gray, D.S.; Winter, J.

    1995-01-01

    Analysis based on the particle conservation law has been carried out to observe the global fuelling process in tokamak discharges. The response of the net recycling flux from the first wall is investigated in the tokamak TEXTOR, using calibrated signals of the gas feed rate, the neutral gas pressure in the vessel, the total amount of electrons, and the particle removal rates by the ALT-II belt-pump limiter and by a main pump unit. Net absorption (pumping) of hydrogen by the wall is observed for almost all tokamak discharges since a new wall conditioning technique called siliconisation is employed. The net absorption or fuelling depending on the discharge condition influenced by injection of pellets, by helium gas injection combined with neutral beam injection, and by rf heating can be interpreted in terms of the particle-induced desorption effect with depth profile taken into consideration. ((orig.))

  5. Compatibility and Stability of VARUBI (Rolapitant) Injectable Emulsion Admixed with Intravenous Palonosetron Hydrochloride Injection and Dexamethasone Sodium Phosphate Injection.

    Science.gov (United States)

    Wu, George; Powers, Dan; Yeung, Stanley; Chen, Frank

    2018-01-01

    Prophylaxis or therapy with a combination of a neurokinin 1 (NK-1) receptor antagonist (RA), a 5-hydroxytryptamine-3 (5-HT3) RA, and dexamethasone is recommended by international antiemesis guidelines for the prevention of chemotherapy-induced nausea and vomiting for patients receiving highly emetogenic chemotherapy and for selected patients receiving moderately emetogenic chemotherapy. VARUBI (rolapitant) is a substance P/NK-1 RA that was recently approved by the U.S. Food and Drug Administration as an injectable emulsion in combination with other antiemetic agents in adults for the prevention of delayed nausea and vomiting associated with initial and repeat courses of emetogenic cancer chemotherapy, including, but not limited to, highly emetogenic chemotherapy. Palonosetron is one of the 5-HT3 RAs indicated for the prevention of nausea and/or vomiting associated with initial and repeat courses of emetogenic cancer therapy, including high-dose cisplatin. Herein, we describe the physical and chemical compatibility and stability of VARUBI injectable emulsion (166.5 mg/92.5 mL [1.8 mg/mL, free base], equivalent to 185 mg of rolapitant hydrochloride) admixed with palonosetron injection 0.25 mg free base in 5 mL (equivalent to 0.28 mg hydrochloride salt) and with either 5 mL (20 mg) or 2.5 mL (10 mg) of dexamethasone sodium phosphate. Admixtures were prepared and stored in VARUBI injectable emulsion ready-to-use glass vials as supplied by the rolapitant manufacturer and in four types of commonly used intravenous administration (tubing) sets. Assessment of the physical and chemical compatibility and stability of the admixtures in the VARUBI ready-to-use vials stored at room temperature (20°C to 25°C) under fluorescent light and under refrigeration (2°C to 8°C protected from light) was conducted at 0, 1, 6, 24, and 48 hours, and that of the admixtures in the intravenous tubing sets was evaluated at 0, 2, and 6 hours of storage at 20°C to 25°C. Physical stability

  6. Anesthetic efficacy of a repeated intraosseous injection given 30 min following an inferior alveolar nerve block/intraosseous injection.

    OpenAIRE

    Reitz, J.; Reader, A.; Nist, R.; Beck, M.; Meyers, W. J.

    1998-01-01

    To determine whether a repeated intraosseous (IO) injection would increase or prolong pulpal anesthesia, we measured the degree of anesthesia obtained by a repeated IO injection given 30 min following a combination inferior alveolar nerve block/intraosseous injection (IAN/IO) in mandibular second premolars and in first and second molars. Using a repeated-measures design, we randomly assigned 38 subjects to receive two combinations of injections at two separate appointments. The combinations w...

  7. A Review of the Effect of Injected Dextranomer/Hyaluronic Acid Copolymer Volume on Reflux Correction Following Endoscopic Injection

    Directory of Open Access Journals (Sweden)

    Sumit Dave

    2008-01-01

    Full Text Available The current literature suggests that multiple variables affect vesicoureteric reflux (VUR resolution rates following dextranomer/hyaluronic acid copolymer (Dx/HA injection. This article reviews the evidence pertaining to the effect of injected Dx/HA volume on success rates following endoscopic correction. Lack of prospective studies which use injected volume as a continuous variable coupled with a nonstandardized injection technique and endpoint hinders the ability to reach a definite conclusion.

  8. Progress with helicity injection current drive

    International Nuclear Information System (INIS)

    Jarboe, T.R.; Raman, R.; Nelson, B.A.

    2003-01-01

    Coaxial Helicity Injection (CHI) experiments in the NSTX and HIT-II devices are reported. NSTX has produced toroidal currents of 0.4 MA and pulse lengths of up to 0.33 s. These discharges nearly fill the NSTX main chamber, and show the n=1 rotating distortion characteristic of high-performance CHI plasmas. CHI has been used in HIT-II to provide a closed flux startup plasma for inductive drive. The CHI startup method saves transformer volt-seconds and greatly improves reproducibility and reliability of inductively driven discharges, even in the presence of diminishing wall conditions. (author)

  9. Nicolau syndrome due to hyaluronic acid injections.

    Science.gov (United States)

    Andre, Pierre; Haneke, Eckart

    2016-08-01

    Six cases of vascular compromise after hyaluronic injection are reported. Clinical symptoms realized a Nicolau syndrome, which is characterized by immediate pain, livedoid pattern and a few days later by the appearance of scabs and skin necrosis. This type of complication is rare, but may be dramatic and injectors must be aware of that. A thorough knowledge of facial anatomy is mandatory to avoid the risky facial areas. The use of a flexible cannula instead of a sharp needle has much less risk of hurting vessels and must be preferred. The support of the patient is discussed and a treatment protocol is proposed.

  10. Heat loss by helicity injection in spheromaks

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1994-01-01

    A model is presented for spheromak buildup and decay including thermal diffusivity associated with magnetic turbulence during helicity injection. It is shown that heat loss by magnetic turbulence scales more favorably than gyroBohm transport. Thus gyroBohm scaling for the proposed ignition experiment would be the conservative choice, though present experiments may be dominated by magnetic turbulence. Because of a change in boundary conditions when the gun is turned off, the model may account for the observed increase in electron temperature in CTX after turnoff

  11. Inverse spin Hall effect by spin injection

    Science.gov (United States)

    Liu, S. Y.; Horing, Norman J. M.; Lei, X. L.

    2007-09-01

    Motivated by a recent experiment [S. O. Valenzuela and M. Tinkham, Nature (London) 442, 176 (2006)], the authors present a quantitative microscopic theory to investigate the inverse spin-Hall effect with spin injection into aluminum considering both intrinsic and extrinsic spin-orbit couplings using the orthogonalized-plane-wave method. Their theoretical results are in good agreement with the experimental data. It is also clear that the magnitude of the anomalous Hall resistivity is mainly due to contributions from extrinsic skew scattering.

  12. Tunneling spin injection into single layer graphene.

    Science.gov (United States)

    Han, Wei; Pi, K; McCreary, K M; Li, Yan; Wong, Jared J I; Swartz, A G; Kawakami, R K

    2010-10-15

    We achieve tunneling spin injection from Co into single layer graphene (SLG) using TiO₂ seeded MgO barriers. A nonlocal magnetoresistance (ΔR(NL)) of 130  Ω is observed at room temperature, which is the largest value observed in any material. Investigating ΔR(NL) vs SLG conductivity from the transparent to the tunneling contact regimes demonstrates the contrasting behaviors predicted by the drift-diffusion theory of spin transport. Furthermore, tunnel barriers reduce the contact-induced spin relaxation and are therefore important for future investigations of spin relaxation in graphene.

  13. Surface multipole guide field for plasma injection

    International Nuclear Information System (INIS)

    Breun, R.A.; Rael, B.H.; Wong, A.Y.

    1977-01-01

    Described here is a surface guide field system which is useful for injection of plasmas into confinement devices. Experimental results are given for 5--25-eV hydrogen plasmas produced by a coaxial discharge (Marshall) gun. It is found that better than 90% of the plasma produced by the gun is delivered to the end of the guide 180 cm away, while the neutral component falls by more than an order of magnitude. For these results the rod current providing the magnetic field had to be large enough to provide at least 1.5-ion gyroradii from the center of the guide to the surface of the inner rod

  14. Log-inject-log in sand consolidation

    International Nuclear Information System (INIS)

    Murphy, R.P.; Spurlock, J.W.

    1977-01-01

    A method is described for gathering information for the determination of the adequacy of placement of sand consolidating plastic for sand control in oil and gas wells. The method uses a high neutron cross-section tracer which becomes part of the plastic and uses pulsed neutron logging before and after injection of the plastic. Preferably, the method uses lithium, boron, indium, and/or cadmium tracers. Boron oxide is especially useful and can be dissolved in alcohol and mixed with the plastic ingredients

  15. Current generation by phased injection of pellets

    International Nuclear Information System (INIS)

    Fisch, N.J.

    1983-08-01

    By phasing the injection of frozen pellets into a tokamak plasma, it is possible to generate current. The current occurs when the electron flux to individual members of an array of pellets is asymmetric with respect to the magnetic field. The utility of this method for tokamak reactors, however, is unclear; the current, even though free in a pellet-fueled reactor, may not be large enough to be worth the trouble. Uncertainty as to the utility of this method is, in part, due to uncertainty as to proper modeling of the one-pellet problem

  16. Tertiary recovery and tritide injection equipment

    International Nuclear Information System (INIS)

    Li Lin

    1989-01-01

    The exploitation of an oil field is a continously developing process, undergoing seveal stages, such as the low production, the high production, the stable production and the decline. The tertiary recovery is an important means of the enhanced oil recovery. Since the object of the tertiary recovery is to treat the oil in micropores which is difficult to be produced, it is more necessary to know further the reservoir. Tritide can be used as a tracer and is an ideal marker of knowing the reservoir and the state of the fluid movement. The paper presents the tritide injection equipment

  17. Impurity pellet injection experiments at TFTR

    International Nuclear Information System (INIS)

    Marmar, E.S.

    1991-01-01

    Impurity (Li and C) pellet experiments, which began at TFTR in 1989, and are expected to continue at least through 1991, have continued to produce new and significant results. The most significant of these are: (1) improvements in TFTR supershots after wall-conditioning by Li pellet injection; (2) accurate measurements of the pitch angle profiles of the internal magnetic field using the polarization angles of line emission from Li + in the pellet ablation cloud; and (3) initial measurements of pitch angle profiles using the tilt of the LI + emission region of the ablation cloud which is stretched out along the field lines

  18. Cross-border drug injection relationships among injection drug users in Tijuana, Mexico

    Science.gov (United States)

    Wagner, Karla D.; Pollini, Robin A.; Patterson, Thomas L.; Lozada, Remedios; Ojeda, Victoria D.; Brouwer, Kimberly C.; Vera, Alicia; Volkmann, Tyson A.; Strathdee, Steffanie A.

    2010-01-01

    Background International borders are unique social and environmental contexts characterized by high levels of mobility. Among drug users, mobility increases risk for human immunodeficiency virus (HIV) in part through its effects on the social environment. However, the social dynamics of drug users living in border regions are understudied. Methods 1056 injection drug users (IDUs) residing in Tijuana, Mexico were recruited using respondent-driven sampling (RDS) from 2006 to 2007, and underwent surveys and testing for HIV, syphilis, and tuberculosis (TB). Using logistic regression on baseline data, we identified correlates of having ever injected drugs with someone from the US. Results Almost half (48%) reported ever injecting drugs with someone from the US. In RDS-adjusted logistic regression, factors independently associated with having ever injected with someone from the US included: having greater than middle school education (Adjusted Odds Ratio [AOR] 2.91; 95% Confidence Interval [C.I.] 1.52, 5.91), speaking English (AOR 3.24, 95% C.I. 1.96, 5.36), age (AOR 1.10 per year; 95% C.I. 1.07, 1.14), age at initiation of injection drug use (AOR 0.90 per year; 95% C.I. 0.86, 0.94), homelessness (AOR 2.61; 95% C.I. 1.27, 5.39), and having ever been incarcerated (AOR 11.82; 95% C.I., 5.22, 26.77). No associations with HIV, syphilis, TB, drug use, or injection risk behavior were detected. Conclusion Findings suggest that IDU networks in Mexico and the US may transcend international borders, with implications for cross-border transmission of infectious disease. Binational programs and policies need to consider the structure and geographic distribution of drug using networks. PMID:20889270

  19. Outcome analysis of two different injection solutions for epidural injection in radicular lumbar backache syndromes

    International Nuclear Information System (INIS)

    Saqib, M.; Mukhtar, M.; Bhatti, S.N; Afridi, E.A.K.; Khan, R.

    2017-01-01

    Background: Backache is a significant source of disability and suffering in our society. The treatment modalities need continued enhancement in order to achieve the desired goals of lowering morbidity and financial losses while improving the response of the patient. Methods: This prospective comparative study was conducted at the department of Orthopaedics and Spine Surgery, Khyber Teaching Hospital Peshawar from July 2013 to June 2015. Two interventional groups were designated; Group 1 was comprised of 54 patients who were injected with epidural bupivacaine plus methylprednisolone while Group 2 included 55 patients who were injected with bupivacaine only. Outcome was assessed using the visual analogue scale and Oswestry disability index (ODI). Results: Fifty-five female and 54 male patients with mean age 49.37 years+-10.46 SD, Mean symptoms duration was 15.01 months+-9.32 SD. Common presenting symptoms were backache (77.1 percent), lower limbs pain (66.1 percent), dermatomal paresthesias (54.1 percent) and neurogenic claudication in 57.8 percent patients. The mean visual analogue score (VAS) after injection was 3.18+-1.29 while mean ODI after injection was 23.615. There was a statistically significant reduction in VAS scores (2-sided p=0.003, OR =4.03, 95 percent CI: 1.535-10.60) following the injection. Conclusion: An epidural spinal injection is a viable option for achieving relief of pain and improves functioning in individuals with radicular backache. However, further research is advised in order to clarify the role of ESI for long-term relief. (author)

  20. Hydrogen/oxygen injection stopping method for nuclear power plant and emergent hydrogen/oxygen injection device

    International Nuclear Information System (INIS)

    Ishida, Ryoichi; Ota, Masamoto; Takagi, Jun-ichi; Hirose, Yuki

    1998-01-01

    The present invention provides a device for suppressing increase of electroconductivity of reactor water during operation of a BWR type reactor, upon occurrence of reactor scram of the plant or upon stopping of hydrogen/oxygen injection due to emergent stoppage of an injection device so as not to deteriorate the integrity of a gas waste processing system upon occurrence of scram. Namely, when injection of hydrogen/oxygen is stopped during plant operation, the injection amount of hydrogen is reduced gradually. Subsequently, injection of hydrogen is stopped. With such procedures, the increase of electroconductivity of reactor water can be suppressed upon stoppage of hydrogen injection. When injection of hydrogen/oxygen is stopped upon shut down of the plant, the amount of hydrogen injection is changed depending on the change of the feedwater flow rate, and then the plant is shut down while keeping hydrogen concentration of feedwater to a predetermined value. With such procedures, increase of the reactor water electroconductivity can be suppressed upon stoppage of hydrogen injection. Upon emergent stoppage of the hydrogen/oxygen injection device, an emergent hydrogen/oxygen injection device is actuated to continue the injection of hydrogen/oxygen. With such procedures, elevation of reactor water electroconductivity can be suppressed. (I.S.)

  1. Drug injecting and HIV risk among injecting drug users in Hai Phong, Vietnam: a qualitative analysis.

    Science.gov (United States)

    Ahmed, Tanvir; Long, Thanh Nguyen; Huong, Phan Thi; Stewart, Donald Edwin

    2015-01-29

    Hai Phong, located in northern Vietnam, has become a high HIV prevalence province among Injecting Drug Users (IDUs) since the infection shifted from the southern to the northern region of the country. Previous research indicates high levels of drug and sex related risk behaviour especially among younger IDUs. Our recent qualitative research provides a deeper understanding of HIV risk behaviour and highlights views and experiences of IDUs relating to drug injecting and sharing practices. Fifteen IDUs participated in semi-structured interviews conducted in September-October, 2012. Eligible participants were selected from those recruited in a larger scale behavioural research project and identified through screening questions. Interviews were conducted by two local interviewers in Vietnamese and were audiotaped. Ethical procedures, including informed consent and participants' understanding of their right to skip and withdraw, were applied. Transcripts were translated and double checked. The data were categorised and coded according to themes. Thematic analysis was conducted and a qualitative data analysis thematic framework was used. Qualitative analysis highlighted situational circumstances associated with HIV risks among IDUs in Hai Phong and revealed three primary themes: (i) places for injecting, (ii) injecting drugs in small groups, and (iii) sharing practices. Our results showed that shared use of jointly purchased drugs and group injecting were widespread among IDUs without adequate recognition of these as HIV risk behaviours. Frequent police raids generated a constant fear of arrest. As a consequence, the majority preferred either rail lines or isolated public places for injection, while some injected in their own or a friend's home. Price, a heroin crisis, and strong group norms encouraged collective preparation and group injecting. Risk practices were enhanced by a number of factors: the difficulty in getting new syringes, quick withdrawal management

  2. Injection Pressure as a Marker of Intraneural Injection in Procedures of Peripheral Nerves Blockade

    Directory of Open Access Journals (Sweden)

    Ilvana Vučković

    2006-11-01

    Full Text Available The blockade of peripheral nerves carries a certain risk of unwanted complications, which can follow after unintentional intraneural injection of a local anesthetic. Up till today, the research of measuring injection pressure has been based on animal models, even though the histological structure of periphery nerve is different for animal and human population, so the application pressure which presages intraneural injection in human population is still unknown. As material in performing this study there have been used 12 Wistar rats and 12 delivered stillborns. After bilateral access to the median nerve, we applied 3 ml of 2% lidocaine with epinephrine, with the help of automatic syringe charger. The needle was at first placed perineural on one side, and then intraneural on the other side of both examination groups. During every application the pressure values were monitored using the manometer, and then they were analyzed by special software program BioBench. All perineural injections resulted with the pressure < or = 27.92 kPa, while the majority of intraneural injections were combined with the injectionpressure > or = 69.8 kPa. The difference between intraneural and perineural injection pressures for the two different examination groups (rats and delivered stillborns was not statistically significant (P>0.05. As prevention from intraneural injections today are in use two methods: the method of causing paresthesia or the method of using the peripheral nerve stimulator. However the nerve injury can still occur, independent from the technique used. If our results are used in clinical practice on human population, than the high injection pressure could be the markerof intraneural lodging of a needle.

  3. Injecting risk behavior among traveling young injection drug users: travel partner and city characteristics.

    Science.gov (United States)

    Montgomery, Martha E; Fatch, Robin S; Evans, Jennifer L; Yu, Michelle; Davidson, Peter J; Page, Kimberly; Hahn, Judith A

    2013-06-01

    Young injection drug users (IDUs), a highly mobile population, engage in high levels of injecting risk behavior, yet little is understood about how such risk behavior may vary by the characteristics of the cities to which they travel, including the existence of a syringe exchange program (SEP), as well as travel partner characteristics. In 2004-2005, we conducted a 6-month prospective study to investigate the risk behavior of 89 young IDUs as they traveled, with detailed information gathered about 350 city visits. In multivariable analyses, travel to larger urban cities with a population of 500,000-1,000,000 was significantly associated with injecting drugs (adjusted odds ratio (AOR) = 3.71; 95 % confidence interval (CI), 1.56-8.82), ancillary equipment sharing (AES; AOR = 7.05; 95 % CI, 2.25-22.06) and receptive needle sharing (RNS; AOR = 5.73; 95 % CI, 1.11-27.95), as compared with visits to smaller cities with populations below 50,000. Region of the country, and the existence of a SEP within the city visited, were not independently associated with injecting drugs, AES, or RNS during city visits. Traveling with more than one injecting partner was associated with injecting drugs during city visits (AOR = 2.77; 95 % CI, 1.46-5.27), when compared with traveling alone. Additionally, both non-daily and daily/almost daily alcohol use during city visits were associated with AES (AOR = 3.37; 95 % CI, 1.42-7.68; AOR = 3.03; 95 % CI, 1.32-6.97, respectively) as compared with no alcohol consumption. Traveling young IDUs are more likely to inject when traveling with other IDUs and to engage in higher risk injection behavior when they are in large cities. Risk behavior occurring in city visits, including equipment sharing and alcohol consumption, suggests further need for focused interventions to reduce risk for viral infection among this population.

  4. Spring-loaded syringe for multiple rapid injections

    Directory of Open Access Journals (Sweden)

    C R Srinivas

    2017-01-01

    Full Text Available Mesotherapy refers to multiple injections of small quantity of the drug over a large area. The mesoguns available are expensive and the motor-driven models tends to waste the expensive material to be injected since the plunger stops after injecting without recoil. We searched for a less expensive device which would inject like the mesogun and still not waste the solution. On searching the web, we identified a spring-loaded syringe. We describe the assembly and use of this inexpensive syringe for delivering multiple injections with minimal wastage.

  5. Spring-loaded Syringe for Multiple Rapid Injections

    Science.gov (United States)

    Srinivas, CR; Somani, Anirudh; Shashidharan Nair, CK; Mylswamy, Thirumurthy

    2017-01-01

    Mesotherapy refers to multiple injections of small quantity of the drug over a large area. The mesoguns available are expensive and the motor-driven models tends to waste the expensive material to be injected since the plunger stops after injecting without recoil. We searched for a less expensive device which would inject like the mesogun and still not waste the solution. On searching the web, we identified a spring-loaded syringe. We describe the assembly and use of this inexpensive syringe for delivering multiple injections with minimal wastage. PMID:28529423

  6. Transverse beam emittance optimization for the injection into BESSY II

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, Felix [Helmholtz Zentrum Berlin, Institut Beschleunigerphysik (Germany); Humboldt-Universitaet zu Berlin, Institut fuer Physik (Germany)

    2016-07-01

    For top up injection into the storage ring BESSY II an average injection efficiency of at least 90% is required. In low alpha mode the injection efficiency does not meet the requirements. Future BESSY II features will include shorter bunches in the storage ring (VSR) and user transparent injection with a non linear kicker. These will raise the demands on the quality of the injected beam even further. This work investigates the development of transverse emittance over the acceleration cycle in the synchrotron and the possibility of transverse emittance exchange by a sequence of skew quadrupoles in the transfer line. Results of emittance measurements and emittance exchange simulations will be given.

  7. Neuropathic Pain Following Poly-L-Lactic Acid (Sculptra) Injection.

    Science.gov (United States)

    Vrcek, Ivan; El-Sawy, Tarek; Chou, Eva; Allen, Theresa; Nakra, Tanuj

    Injectable fillers have become a prevalent means of facial rejuvenation and volume expansion. While typically well tolerated, serious complications have been reported. The authors present a case in which an otherwise healthy female with a history of multiple filler injections including poly-L-lactic acid, developed 3 weeks of neuropathic pain in the left temporal fossa following injection. To the best of the authors knowledge, neuropathic pain has not been reported as a complication following poly-L-lactic acid injection. The patient was treated with an injection of steroid and long-acting anesthetic with resolution of symptoms.

  8. 160 MeV $H^-$ Injection into the CERN PSB

    CERN Document Server

    Weterings, W; Borburgh, J; Fowler, T; Gerigk, F; Goddard, B; Hanke, K; Martini, M; Sermeus, L

    2007-01-01

    The H- beam from the proposed LINAC4 will be injected into the four existing rings of the PS Booster at 160 MeV. A substantial upgrade of the injection region is required, including the modification of the beam distribution system and the construction of a new H- injection system. This paper discusses beam dynamics and hardware requirements and presents the results of optimisation studies of the injection process for different beam characteristics and scenarios. The resulting conceptual design of the injection region is presented, together with the main hardware modifications and performance specifications.

  9. Innovative measurement for injection systems; Innovative Messtechnik fuer Einspritzsysteme

    Energy Technology Data Exchange (ETDEWEB)

    Janetzky, Bjoern; Majer, Clemens; Doell, Reinahrd [Robert Bosch GmbH, Stuttgart (Germany)

    2011-07-01

    The treatise introduces a new measuring method to determine the injection quantity and injection rate. In this method the change in pressure within a hydraulic chamber is measured during injection. Also the momentary pressure-dependent speed of sound of the medium inside the chamber is measured. With this information the desired injection quantity can be derived with high precision. A measuring technique (HDA) based on this method is described. Measurement with HDA are performed based on actual requirements from the Diesel-Injection-System, results from these measurements are presented in example. Results are compared with those achieved by using a known measuring technique (EMI). (orig.)

  10. Incidence of plantar fascia ruptures following corticosteroid injection.

    Science.gov (United States)

    Kim, Chul; Cashdollar, Michael R; Mendicino, Robert W; Catanzariti, Alan R; Fuge, LaDonna

    2010-12-01

    Plantar fasciitis is commonly treated with corticosteroid injections to decrease pain and inflammation. Therapeutic benefits often vary in terms of efficacy and duration. Rupture of the plantar fascia has been reported as a possible complication following corticosteroid injection. A retrospective chart review of 120 patients who received corticosteroid injection for plantar fasciitis was performed at the authors' institution to determine the incidence of plantar fascia rupture. The plantar fascia rupture was diagnosed clinically and confirmed with magnetic resonance imaging. Various factors were analyzed, including the number of injections, interval between injections, body mass index (BMI), and activity level. Four patients (2.4%) consequently experienced plantar fascia rupture following an average of 2.67 injections. The average BMI of these patients was 38.6 kg/m². The authors conclude that corticosteroid injection therapy appears to be a safe and effective form of nonoperative treatment with minimal complications and a relatively low incident of plantar fascia rupture.

  11. Injection-induced moment release can also be aseismic

    Science.gov (United States)

    McGarr, Arthur; Barbour, Andrew J.

    2018-01-01

    The cumulative seismic moment is a robust measure of the earthquake response to fluid injection for injection volumes ranging from 3100 to about 12 million m3. Over this range, the moment release is limited to twice the product of the shear modulus and the volume of injected fluid. This relation also applies at the much smaller injection volumes of the field experiment in France reported by Guglielmi, et al. (2015) and laboratory experiments to simulate hydraulic fracturing described by Goodfellow, et al. (2015). In both of these studies, the relevant moment release for comparison with the fluid injection was aseismic and consistent with the scaling that applies to the much larger volumes associated with injection-induced earthquakes with magnitudes extending up to 5.8. Neither the micro-earthquakes, at the site in France, nor the acoustic emission in the laboratory samples contributed significantly to the deformation due to fluid injection.

  12. Injection system of teh SSC Medium Energy Booster

    International Nuclear Information System (INIS)

    Mao, N.; Gerig, R.; McGill, J.; Brown, K.

    1994-04-01

    The Medium Energy Booster (MEB) is the third of the SSCL accelerators and the largest of the resistive magnet synchrotrons. It accelerates protons from an injection momentum of 12 GeV/c to a top momentum of 200 GeV/c. A beam injection system has been designed to inject the beam transferred from the Low Energy Booster onto the MEB closed orbit in the MEB injection insertion region. The beam is injected via a vertical bending Lambertson septum magnet and a horizontal kicker with appropriate matching and very little beam loss and emittance dilution. The beam optics of the injection system is described in this paper. The required parameters of the Lambertson septum magnet and the injection kicker are given

  13. Pellet injection experiments on the TFR Tokamak

    International Nuclear Information System (INIS)

    1987-02-01

    Single pellet injection experiments have been carried out on TFR with the aim to improve the experimental knowledge of ablation physical processes and also to get a better description of the heat and matter transport during and after pellet evaporation. Ablation clouds have been photographed, providing experimental penetration depths in rough agreement with the neutral shielding model. Observation of striations in the cloud has led to an experimental determination of the safety factor profile. Parameters of the plasma in the ablation cloud have been spectroscopically determined. Fast heat transport has been evidenced during pellet evaporation (∼ 100 μs) which exhibits some features of minor or major disruptions (appearance of a m = 1, n = 1 island on the q = 1 surface, bursts of density fluctuations, comparable heat diffusivity, ...). Matter transport takes place on a larger time scale (∼ 10 ms). This long temporal relaxation is well accounted for by the 1D-MAKOKOT computer code without changing the transport coefficients after pellet injection. Heat and matter transport are affected by the presence of the m = 1, n = 1 island on the q = 1 surface

  14. Injectable hydrogels for central nervous system therapy

    International Nuclear Information System (INIS)

    Pakulska, Malgosia M; Shoichet, Molly S; Ballios, Brian G

    2012-01-01

    Diseases and injuries of the central nervous system (CNS) including those in the brain, spinal cord and retina are devastating because the CNS has limited intrinsic regenerative capacity and currently available therapies are unable to provide significant functional recovery. Several promising therapies have been identified with the goal of restoring at least some of this lost function and include neuroprotective agents to stop or slow cellular degeneration, neurotrophic factors to stimulate cellular growth, neutralizing molecules to overcome the inhibitory environment at the site of injury, and stem cell transplant strategies to replace lost tissue. The delivery of these therapies to the CNS is a challenge because the blood–brain barrier limits the diffusion of molecules into the brain by traditional oral or intravenous routes. Injectable hydrogels have the capacity to overcome the challenges associated with drug delivery to the CNS, by providing a minimally invasive, localized, void-filling platform for therapeutic use. Small molecule or protein drugs can be distributed throughout the hydrogel which then acts as a depot for their sustained release at the injury site. For cell delivery, the hydrogel can reduce cell aggregation and provide an adhesive matrix for improved cell survival and integration. Additionally, by choosing a biodegradable or bioresorbable hydrogel material, the system will eventually be eliminated from the body. This review discusses both natural and synthetic injectable hydrogel materials that have been used for drug or cell delivery to the CNS including hyaluronan, methylcellulose, chitosan, poly(N-isopropylacrylamide) and Matrigel. (paper)

  15. Compact toroid injection into C-2U

    Science.gov (United States)

    Roche, Thomas; Gota, H.; Garate, E.; Asai, T.; Matsumoto, T.; Sekiguchi, J.; Putvinski, S.; Allfrey, I.; Beall, M.; Cordero, M.; Granstedt, E.; Kinley, J.; Morehouse, M.; Sheftman, D.; Valentine, T.; Waggoner, W.; the TAE Team

    2015-11-01

    Sustainment of an advanced neutral beam-driven FRC for a period in excess of 5 ms is the primary goal of the C-2U machine at Tri Alpha Energy. In addition, a criteria for long-term global sustainment of any magnetically confined fusion reactor is particle refueling. To this end, a magnetized coaxial plasma-gun has been developed. Compact toroids (CT) are to be injected perpendicular to the axial magnetic field of C-2U. To simulate this environment, an experimental test-stand has been constructed. A transverse magnetic field of B ~ 1 kG is established (comparable to the C-2U axial field) and CTs are fired across it. As a minimal requirement, the CT must have energy density greater than that of the magnetic field it is to penetrate, i.e., 1/2 ρv2 >=B2 / 2μ0 . This criteria is easily met and indeed the CTs traverse the test-stand field. A preliminary experiment on C-2U shows the CT also capable of penetrating into FRC plasmas and refueling is observed resulting in a 20 - 30% increase in total particle number per single-pulsed CT injection. Results from test-stand and C-2U experiments will be presented.

  16. The Injection System of SAGA Light Source

    CERN Document Server

    Iwasaki, Yoshitaka; Ohgaki, Hideaki; Okajima, Toshihiro; Takabayashi, Yuichi; Tomimasu, Takio; Yoshida, Katuhide

    2005-01-01

    Saga light Source is a 1.4-GeV electron storage ring with a circumference of 75.6m. The injector is a 250-MeV linac producing 1 ms macro-pulse with a peak current of 12mA and repetition rate of 1Hz. The output beam from the linac is transported though a transport line, and injected into the ring though a septum magnet with a bending angle of 20-degree. The transport line consists of two bending magnets, two quadrupole doublelets, and a quadrupole singlet. The bump orbit is formed by four kicker magnets, two of which are installed at both sides of septum magnet, and other two are positioned apart by one magnet cell of the ring. They are excited by sinusoidal electric currents with a half width of 0.5 ms. The beam optics for the injection trajectory is computed and shown at control room, the parameters for which are provided directly from the power supply control server PC. The operator is able to see real-time result of the beam trajectory calculation. This tool is quite effective to optimize the magnets param...

  17. MD2190: Q" Stabilization during injection

    CERN Document Server

    Schenk, Michael; Li, Kevin Shing Bruce; Malina, Lukas; Metral, Elias; Tomas Garcia, Rogelio; CERN. Geneva. ATS Department

    2018-01-01

    This MD is a follow-up study of MD1831, where single bunches were stabilized against impedance-driven instabilities at 6.5 TeV in the LHC with Q''. The goals are (i) to explore whether an amplitude detuning free Q'' knob can be implemented at injection energy, and (ii) whether Q'' can provide beam stability at injection, where the beams suffer mostly from electron cloud effects. Ideally, this would relax the use of the Landau octupoles and may help in preserving the beam quality by reducing dynamic aperture limitations originating from the octupoles. The MD has been split into two parts: First, optics corrections were put in place to minimize beta-beating and linear coupling introduced by the knobs. The corrections were achieved by means of orbit bumps and skew quadrupole knobs. Machine safety was then validated with loss maps. While the betatron loss maps were approved, the off-momentum maps showed a priori unexpected losses in several arcs and the MD was stopped at this point for reasons of machine protecti...

  18. Passive safety injection experiments and analyses (PAHKO)

    International Nuclear Information System (INIS)

    Tuunanen, J.

    1998-01-01

    PAHKO project involved experiments on the PACTEL facility and computer simulations of selected experiments. The experiments focused on the performance of Passive Safety Injection Systems (PSIS) of Advanced Light Water Reactors (ALWRs) in Small Break Loss-Of-Coolant Accident (SBLOCA) conditions. The PSIS consisted of a Core Make-up Tank (CMT) and two pipelines (Pressure Balancing Line, PBL, and Injection Line, IL). The examined PSIS worked efficiently in SBLOCAs although the flow through the PSIS stopped temporarily if the break was very small and the hot water filled the CMT. The experiments demonstrated the importance of the flow distributor in the CMT to limit rapid condensation. The project included validation of three thermal-hydraulic computer codes (APROS, CATHARE and RELAP5). The analyses showed the codes are capable to simulate the overall behaviour of the transients. The detailed analyses of the results showed some models in the codes still need improvements. Especially, further development of models for thermal stratification, condensation and natural circulation flow with small driving forces would be necessary for accurate simulation of the PSIS phenomena. (orig.)

  19. Achieving improved ohmic confinement via impurity injection

    International Nuclear Information System (INIS)

    Bessenrodt-Weberpals, M.; Soeldner, F.X.

    1991-01-01

    Improved Ohmic Confinement (IOC) was obtained in ASDEX after a modification of the divertors that allowed a larger (deuterium and impurity) backflow from the divertor chamber. The quality of IOC depended crucially on the wall conditions, i.e. IOC was best for uncovered stainless steels walls and vanished with boronization. Furthermore, IOC was found only in deuterium discharges. These circumstances led to the idea that IOC correlates with the content of light impurities in the plasma. To substantiate this working hypothesis, we present observations in deuterium discharges with boronized wall conditions into which various impurities have been injected with the aim to induce IOC conditions. Firstly, the plasma behaviour in typical IOC discharges is characterized. Secondly, injection experiments with the low-Z impurities nitrogen and neon as well as with the high-Z impurities argon and krypton are discussed. Then, we concentrate on optimized neon puffing that yields the best confinement results which are similar to IOC conditions. Finally, these results are compared with eperiments in other tokamaks and some conclusions are drawn about the effects of the impurity puffing on both, the central and the edge plasma behaviour. (orig.)

  20. Determining How Magnetic Helicity Injection Really Works

    International Nuclear Information System (INIS)

    Paul M Bellan

    2001-01-01

    OAK-B135 The goal of the Caltech program is to determine how helicity injection works by investigating the actual dynamics and topological evolution associated with magnetic relaxation. A new coaxial helicity injection source has been constructed and brought into operation. The key feature of this source is that it has maximum geometric simplicity. Besides being important for fusion research, this work also has astrophysical implications. Photos obtained using high-speed cameras show a clear sequence of events in the formation process. In particular, they show initial merging/reconnection processes, jet-like expansion, kinking, and separation of the plasma from the source. Various diagnostics have been developed, including laser induced fluorescence and soft x-ray detection using high speed diodes. Gas valves have been improved and a patent disclosure relating to puffed gas valves has been filed. Presentations on this work have been given in the form of invited talks at several university physics departments that were previously unfamiliar with laboratory plasma experiments