WorldWideScience

Sample records for injection lab-on-valve analysis

  1. Sequential injection lab-on-valve: the third generation of flow injection analysis

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2003-01-01

    Termed the third generation of flow injection analysis, sequential injection (SI)-lab-on-valve (LOV) has specific advantages and allows novel, unique applications - not least as a versatile front end to a variety of detection techniques. This review presents snd discusses progress to date of the ...

  2. New Trends in Flow Injection Analysis: Exploitation of Sequential and Lab-on-Valve Schemes

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    has appeared, that is, the Lab-on-Valve (LOV) approach, the conceptual basis of which is to incorporate all the necessary unit operational manipulations required, and, when possible, even the detection device into a single small integrated microconduit, or “laboratory”, placed atop a selection valve...... sensitivity and selectivity. Either in order to separate/preconcentrate the analyte material, or because of the presence of potentially interfering matrix constituents. Such pretreatments are advantageously performed in FIA/SIA/LOV manifolds, where all appropriate unit operations can be effected under...

  3. A LabVIEW®-based software for the control of the AUTORAD platform. A fully automated multisequential flow injection analysis Lab-on-Valve (MSFIA-LOV) system for radiochemical analysis

    International Nuclear Information System (INIS)

    Barbesi, Donato; Vilas, Victor Vicente; Millet, Sylvain; Sandow, Miguel; Colle, Jean-Yves; Heras, Laura Aldave de las

    2017-01-01

    A LabVIEW®-based software for the control of the fully automated multi-sequential flow injection analysis Lab-on-Valve (MSFIA-LOV) platform AutoRAD performing radiochemical analysis is described. The analytical platform interfaces an Arduino®-based device triggering multiple detectors providing a flexible and fit for purpose choice of detection systems. The different analytical devices are interfaced to the PC running LabVIEW®VI software using USB and RS232 interfaces, both for sending commands and receiving confirmation or error responses. The AUTORAD platform has been successfully applied for the chemical separation and determination of Sr, an important fission product pertinent to nuclear waste. (author)

  4. A LabVIEW®-based software for the control of the AUTORAD platform: a fully automated multisequential flow injection analysis Lab-on-Valve (MSFIA-LOV) system for radiochemical analysis.

    Science.gov (United States)

    Barbesi, Donato; Vicente Vilas, Víctor; Millet, Sylvain; Sandow, Miguel; Colle, Jean-Yves; Aldave de Las Heras, Laura

    2017-01-01

    A LabVIEW ® -based software for the control of the fully automated multi-sequential flow injection analysis Lab-on-Valve (MSFIA-LOV) platform AutoRAD performing radiochemical analysis is described. The analytical platform interfaces an Arduino ® -based device triggering multiple detectors providing a flexible and fit for purpose choice of detection systems. The different analytical devices are interfaced to the PC running LabVIEW ® VI software using USB and RS232 interfaces, both for sending commands and receiving confirmation or error responses. The AUTORAD platform has been successfully applied for the chemical separation and determination of Sr, an important fission product pertinent to nuclear waste.

  5. Extraction and preconcentration of trace levels of cobalt using functionalized magnetic nanoparticles in a sequential injection lab-on-valve system with detection by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Wang Yang; Luo Xiaoyu; Tang Jie; Hu Xiaoya; Xu Qin; Yang Chun

    2012-01-01

    Graphical abstract: An approach to performing extraction and preconcentration employing functionalized magnetic particles for the determination of cobalt in the sequential injection lab-on-valve system using detection by electrothermal atomic absorption spectrometry. Highlights: ► New SPE method for cobalt separation/preconcentration was reported. ► Functionalized magnetic nanoparticles were used as adsorbent. ► Extraction, elution, and detection procedures were performed in the LOV system. ► This automatic extraction technique provided a good platform for metal analysis. - Abstract: A new approach to performing extraction and preconcentration employing functionalized magnetic nanoparticles for the determination of trace metals is presented. Alumina-coated iron oxide nanoparticles were synthesized and used as the solid support. The nanoparticles were functionalized with sodium dodecyl sulfate and used as adsorbents for solid phase extraction of the analyte. Extraction, elution, and detection procedures were performed sequentially in the sequential injection lab-on-valve (SI-LOV) system followed by electrothermal atomic absorption spectrometry (ETAAS). Mixtures of hydrophobic analytes were successfully extracted from solution using the synthesized magnetic adsorbents. The potential use of the established scheme was demonstrated by taking cobalt as a model analyte. Under the optimal conditions, the calibration curve showed an excellent linearity in the concentration range of 0.01–5 μg L −1 , and the relative standard deviation was 2.8% at the 0.5 μg L −1 level (n = 11). The limit of detection was 6 ng L −1 with a sampling frequency of 18 h −1 . The present method has been successfully applied to cobalt determination in water samples and two certified reference materials.

  6. Bead Injection Extraction Chromatography using High-capacity Lab-on-Valve as a Front End to Inductively Coupled Plasma Mass Spectrometry for Rapid Urine Radiobioassay

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2013-01-01

    A novel bead injection (BI) extraction chromatographic microflow system exploiting high-capacity lab-on-valve (LOV) platform coupled with inductively coupled plasma mass spectrometric detection is developed for rapid and automated determination of plutonium in human urine. A microconduit (1 m......L) incorporated within the LOV processing unit is loaded on-line with a metered amount of disposable extraction chromatographic resin (up to 330 mg of TEVA) through programmable beads transport. Selective capture and purification of plutonium onto the resin beads is then performed by pressure driven flow after...

  7. Determination of trace metal ions via on-line separation and preconcentration by means of chelating Sepharose beads in a sequential injection lab-on-valve (SI-LOV) system coupled to electrothermal atomic absorption spectrometric detection

    DEFF Research Database (Denmark)

    Long, Xiangbao; Hansen, Elo Harald; Miró, Manuel

    2005-01-01

    The analytical performance of an on-line sequential injection lab-on-valve (SI-LOV) system using chelating Sepharose beads as sorbent material for the determination of ultra trace levels of Cd(II), Pb(II) and Ni(II) by electrothermal atomic absorption spectrometry (ETAAS) is described and discussed...

  8. Evaluation of a novel PTFE material for separation and preconcentration of trace levels of metal ions in sequential injection (SI) and sequential injection lab-on-valve (SI-LOV) systems interfaced with detection by ETAAS

    DEFF Research Database (Denmark)

    Long, Xiangbao; Chomchoei, Roongrat; Gała, Piotr

    The operational characteristics of a novel PTFE bead material, granular Algoflon®, used for separation and preconcentration of metal ions via adsorption of on-line generated non-charged metal complexes, were evaluated in a sequential injection (SI) system furnished with an external packed column...... and in a sequential injection lab-on-valve (SI-LOV) system. Employed for the determination of cadmium(II), complexed with diethyldithiophosphate (DDPA), and detection by electrothermal atomic absorption spectrometry (ETAAS), its performance was compared to that of a previously used material, Aldrich PTFE, which had...... demonstrated that PTFE was the most promising for solid-state pretreatments. By comparing the two materials, the Algoflon® beads exhibited much higher sensitivity (1.6107 versus 0.2956 μg l-1 per integrated absorbance (s)), and better retention efficiency (82% versus 74%) and enrichment factor (20.8 versus 17...

  9. On-line dynamic extraction and automated determination of readily bioavailable hexavalent chromium in solid substrates using micro-sequential injection bead-injection lab-on-valve hyphenated with electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald

    2006-01-01

    A novel and miniaturized micro-sequential injection bead injection lab-on-valve (μSI-BI-LOV) fractionation system was developed for in-line microcolumn soil extraction under simulated environmental scenarios and accurate monitoring of the content of easily mobilisable hexavalent chromium in soil...... environments at the sub-low parts-per-million level. The flow system integrates dynamic leaching of hexavalent chromium using deionized water as recommended by the German Standard DIN 38414-S4 method; on-line pH adjustment of the extract by a 0.01 mol L-1 Tris-HNO3 buffer solution; isolation of the chromate...... polluted agricultural soil material (San Joaquin Soil-Baseline Trace Element Concentrations) with water-soluble Cr(VI) salts at different concentration levels. The potential of the μSI-BI-LOV set-up with renewable surfaces for flame-AAS determination of high levels of readily bioavailable chromate...

  10. Exploiting the bead-injection approach in the integrated sequential injection Lab-on-Valve format using hydrophobic packing materials for on-line matrix removal and preconcentration of trace levels of cadmium in environmental and biological samples via formation of non-charged chelates prior

    DEFF Research Database (Denmark)

    Miró, Manuel; Jonczyk, Sylwia; Wang, Jianhua

    2003-01-01

    The concept of renewable microcolumns within the conduits of an automated single injection lab-on-valve system was exploited in a sorption/elution fashion using sorbents of hydrophobic nature. The scheme's practical applicability was demonstrated for the electrothermal atomic absorption spectrome......The concept of renewable microcolumns within the conduits of an automated single injection lab-on-valve system was exploited in a sorption/elution fashion using sorbents of hydrophobic nature. The scheme's practical applicability was demonstrated for the electrothermal atomic absorption...

  11. Lab-on-Valve Micro Sequential Injection: A Versatile Approach for Implementing Integrated Sample Pre-preparations and Executing (Bio)Chemical Assays

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    waste generation. Most recently, the socalled third generation of FIA has emerged, that is, the Lab-on-Valve (LOV) approach, the conceptual basis of which is to incorporate all the necessary unit operational manipulations required, and, when possible, even the detection device into a single small...... integrated microconduit, or “laboratory”, placed atop a selection valve. The lecture will detail the evolution of the three generations of FIA, emphasis being placed on the LOV approach. Proven itself as a versatile front end to a variety of detection techniques, its utility will be exemplified by a series...... of the renewable microcolumn concept. Despite their excellent analytical chemical capabilities, ETAAS as well as ICPMS often require that the samples are subjected to suitable pretreatment in order to obtain the necessary sensitivity and selectivity. Either in order to separate the analyte from potentially...

  12. Lab-on-Valve Micro Sequential Injection: A Versatile Approach for Implementing Integrated Sample Pre-preparations and Executing (Bio)Chemical Assays

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    waste generation. Most recently, the Lab-on-Valve (LOV) approach has emerged. Termed the third generation of FIA, the conceptual basis of the LOV is to incorporate all the necessary unit operational manipulations required in a chemical assay, and, when possible, even the detection device, into a single...... small integrated microconduit, or “laboratory”, placed atop a selection valve. In the lecture emphasis will be placed on the LOV approach. Proven itself as a versatile front end to a variety of detection techniques, its utility will be exemplified by various applications. Particular focus......-phase microcolumn concept utilising hydrophobic as well as hydrophilic bead materials. Although ETAAS and ICPMS both are characterised by excellent analytical chemical capabilities, they nevertheless often require that the samples be subjected to suitable pretreatment in order to obtain the necessary sensitivity...

  13. Highly selective micro-sequential injection lab-on-valve (muSI-LOV) method for the determination of ultra-trace concentrations of nickel in saline matrices using detection by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Long, Xiangbao; Miró, Manuel; Jensen, Rikard; Hansen, Elo Harald

    2006-10-01

    A highly selective procedure is proposed for the determination of ultra-trace level concentrations of nickel in saline aqueous matrices exploiting a micro-sequential injection Lab-On-Valve (muSI-LOV) sample pretreatment protocol comprising bead injection separation/pre-concentration and detection by electrothermal atomic absorption spectrometry (ETAAS). Based on the dimethylglyoxime (DMG) reaction used for nickel analysis, the sample, as contained in a pH 9.0 buffer, is, after on-line merging with the chelating reagent, transported to a reaction coil attached to one of the external ports of the LOV to assure sufficient reaction time for the formation of Ni(DMG)(2) chelate. The non-ionic coordination compound is then collected in a renewable micro-column packed with a reversed-phase copolymeric sorbent [namely, poly(divinylbenzene-co-N-vinylpyrrolidone)] containing a balanced ratio of hydrophilic and lipophilic monomers. Following elution by a 50-muL methanol plug in an air-segmented modality, the nickel is finally quantified by ETAAS. Under the optimized conditions and for a sample volume of 1.8 mL, a retention efficiency of 70 % and an enrichment factor of 25 were obtained. The proposed methodology showed a high tolerance to the commonly encountered alkaline earth matrix elements in environmental waters, that is, calcium and magnesium, and was successfully applied for the determination of nickel in an NIST standard reference material (NIST 1640-Trace elements in natural water), household tap water of high hardness and local seawater. Satisfying recoveries were achieved for all spiked environmental water samples with maximum deviations of 6 %. The experimental results for the standard reference material were not statistically different to the certified value at a significance level of 0.05.

  14. Evaluation of a novel PTFE material for use as a means for separation and preconcentration of trace levels of metal ions in sequential injection (SI) and sequential injection lab-on-valve (SI-LOV) systems. Determination of cadmium (II) with detection by electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Long, Xiangbao; Chomchoei, Roongrat; Hansen, Elo Harald

    2004-01-01

    with an external packed column and in a sequential injection lab-on-valve (SI-LOV) system. Employed for the determination of cadmium(II), complexed with diethyldithiophosphate (DDPA), and detection by electrothermal atomic absorption spectrometry (ETAAS), its performance was compared to that of a previously used...

  15. Sequential injection-bead injection-lab-on-valve schemes for on-line solid phase extraction and preconcentration of ultra-trace levels of heavy metals with determination by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Wang Jianhua; Hansen, Elo Harald; Miro, Manuel

    2003-01-01

    This communication presents an overview of the state-of-the-art of the exploitation of sequential injection (SI)-bead injection (BI)-lab-on-valve (LOV) schemes for automatic on-line sample pre-treatments interfaced with ETAAS and ICPMS detection as conducted in the authors' group. The discussions are focused on the applications of SI-BI-LOV protocols for on-line microcolumn based solid phase extraction of ultra-trace levels of heavy metals, employing the so-called renewable surface separation and preconcentration manipulatory scheme. Two types of sorbents have been employed as packing material, that is, the hydrophilic SP Sephadex C-25 cation exchange and iminodiacetate based Muromac A-1 chelating resins, and the hydrophobic poly(tetrafluoroethylene) (PTFE) and poly(styrene-divinylbenzene) copolymer alkylated with octadecyl groups (C 18 -PS/DVB). Using ETAAS as detection device, the easy-to-handle hydrophilic renewable reactors hold the features of improved R.S.D.s and LODs as compared to those operated in the conventional, permanent mode, in addition to the elimination of flow resistance. The hydrophobic columns fall into two categories, that is, the renewable one packed with C 18 -PS/DVB beads entails analogous R.S.D.s and LODs with respect to the conventional approach, while those with PTFE beads result in slightly inferior R.S.D.s and LODs by similar comparison, yet offering a wider dynamic range than when using an external permanent column. Moreover, the hydrophilic materials result in much higher enrichment of the analyte than the hydrophobic ones, although PTFE is the packing material that exhibits the best retention efficiency

  16. A Universal Approach for Selective Trace Metal Determinations via Sequential Injection-Bead Injection-Lab-on-Valve (SI-BI-LOV) Using Renewable Reagent-loaded Hydrophobic Beads

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald

    -Lab-on-Valve (SI-LOV) mode. The methodology uses poly(styrene-divinylbenzene) beads containing pendant octadecyl moieties (C18-PS/DVB), which are pre-impregnated with a selective organic metal chelating agent prior to the automatic manipulation of the beads in the microbore conduits of the LOV unit. By adapting...

  17. Recent developments in automated determinations of trace level concentrations of elements and on-line fractionations schemes exploiting the micro-sequential injection - lab-on-valve approach

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Miró, Manuel; Long, Xiangbao

    2006-01-01

    The determination of trace level concentrations of elements, such as metal species, in complex matrices by atomic absorption or emission spectrometric methods often require appropriate pretreatments comprising separation of the analyte from interfering constituents and analyte preconcentration...... are presented as based on the exploitation of micro-sequential injection (μSI-LOV) using hydrophobic as well as hydrophilic bead materials. The examples given comprise the presentation of a universal approach for SPE-assays, front-end speciation of Cr(III) and Cr(VI) in a fully automated and enclosed set...

  18. Exploiting the Lab-on-Valve Concept for Determination of Trace Levels of Metals in Complex Matrices with Detection by ETAAS and ICPMS

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Wang, Jianhua

    approach [1,2]. Coupled to detection by ETAAS and ICPMS, and illustrated by recent exploits in the authors’ laboratory, it is shown that this methodology eliminates the problems encountered in conventional on-line column preconcentration systems and at the same time improves the overall operational......Termed the third generation of flow injection analysis, the Sequential Injection (SI)-Lab-on-Valve (LOV) concept has proven to entail specific advantages and to allow novel and unique applications. Both in term of its use in the automation and micro-miniaturization of suitable on-line sample...

  19. The Impact of Flow Injection on Modern Chemical Analysis

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    and preconcentration procedures. In recent years, FIA has been supplemented by Sequential Injection Analysis (SIA) and the Lab-on-Valve (LOV) approach. Following a brief historic introduction and an account of the impact of FIA in academia, the lecture will describe these two new generations of FIA, accompanied...

  20. Towards an automatic lab-on-valve-ion mobility spectrometric system for detection of cocaine abuse.

    Science.gov (United States)

    Cocovi-Solberg, David J; Esteve-Turrillas, Francesc A; Armenta, Sergio; de la Guardia, Miguel; Miró, Manuel

    2017-08-25

    A lab-on-valve miniaturized system integrating on-line disposable micro-solid phase extraction has been interfaced with ion mobility spectrometry for the accurate and sensitive determination of cocaine and ecgonine methyl ester in oral fluids. The method is based on the automatic loading of 500μL of oral fluid along with the retention of target analytes and matrix clean-up by mixed-mode cationic/reversed-phase solid phase beads, followed by elution with 100μL of 2-propanol containing (3% v/v) ammonia, which are online injected into the IMS. The sorptive particles are automatically discarded after every individual assay inasmuch as the sorptive capacity of the sorbent material is proven to be dramatically deteriorated with reuse. The method provided a limit of detection of 0.3 and 0.14μgL -1 for cocaine and ecgonine methyl ester, respectively, with relative standard deviation values from 8 till 14% with a total analysis time per sample of 7.5min. Method trueness was evaluated by analyzing oral fluid samples spiked with cocaine at different concentration levels (1, 5 and 25μgL -1 ) affording relative recoveries within the range of 85±24%. Fifteen saliva samples were collected from volunteers and analysed following the proposed automatic procedure, showing a 40% cocaine occurrence with concentrations ranging from 1.3 to 97μgL -1 . Field saliva samples were also analysed by reference methods based on lateral flow immunoassay and gas chromatography-mass spectrometry. The application of this procedure to the control of oral fluids of cocaine consumers represents a step forward towards the development of a point-of-care cocaine abuse sensing system. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. On-line ion exchange preconcentration in a sequential injection lab-on-valve microsystem incorporating a renewable column with ETAAS for the trace-level determination of bismuth in urine and river sediment

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2001-01-01

    A sequential injection system for on-line ion-exchange separation and preconcentration of trace-level amounts of metal ions with ensuing detection by electrothermal atomic absorption spectrometry (ETAAS) is described. Based on the use of a renewable microcolumn incorporated within an integrated l.......3% for the determination of 2.0 mug/l Bi (n = 7). The procedure was validated by determination of bismuth in a certified reference material CRM 320 (river sediment), and by bismuth spike recoveries in two human urine samples....

  2. Trends and perspectives of flow injection/sequential injection on-line sample-pretreatment schemes coupled to ETAAS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2005-01-01

    Flow injection (FI) analysis, the first generation of this technique, became in the 1990s supplemented by its second generation, sequential injection (SI), and most recently by the third generation (i.e.,Lab-on-Valve). The dominant role played by FI in automatic, on-line, sample pretreatments in ...

  3. Determination of trace zinc in seawater by coupling solid phase extraction and fluorescence detection in the Lab-On-Valve format.

    Science.gov (United States)

    Grand, Maxime M; Chocholouš, Petr; Růžička, Jarda; Solich, Petr; Measures, Christopher I

    2016-06-07

    By virtue of their compactness, long-term stability, minimal reagent consumption and robustness, miniaturized sequential injection instruments are well suited for automation of assays onboard research ships. However, in order to reach the sensitivity and limit of detection required for open-ocean determinations of trace elements, it is necessary to preconcentrate the analyte prior its derivatization and subsequent detection by fluorescence. In this work, a novel method for the determination of dissolved zinc (Zn) at subnanomolar levels in seawater is described. The proposed method combines, for the first time, automated matrix removal, extraction of the target element, and fluorescence detection within a miniaturized flow manifold, based on the Lab-On-Valve (LOV) concept. The key feature of the microfluidic manipulation of the sample is flow programming, designed to pass sample through a mini-column where the target analyte and other complexable cations are retained, while the seawater matrix is washed out. Next, zinc is eluted and merged with a Zn selective fluorescent probe (FluoZin-3) at the confluence point of the LOV central channel using two high-precision stepper motor driven pumps that are operated in concert. Finally, the thus formed Zn complex is transported to the LOV flow cell for selective fluorescence measurement. This work describes the characterization and optimization of the method including Solid Phase Extraction using the Toyopearl AF-Chelate-650M resin, and detailed assay protocol controlled by a commercially available software and instrument. The proposed method features a LOD of 0.02 nM, high precision (seawater reference standards and comparison with ICP-MS determinations on seawater samples collected in the upper 1300 m of the subtropical south Indian Ocean. This work confirms that integration of sample pretreatment with optical detection in the LOV format offers a widely applicable approach to trace analysis of seawater. Copyright © 2016

  4. Hyphenating multisyringe flow injection lab-on-valve analysis with atomic fluorescence spectrometry for on-line bead-injection preconcentration and determination of trace levels of hydride-forming elements in environmental samples

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald

    2006-01-01

    the determination of ultratrace level concentrations of total inorganic arsenic in freshwater. Employing quantitative preoxidation of As(III) to As(V) in the samples by means of permanganate, the method involves the preconcentration of arsenate at pH 10 on a renewable anion exchanger, namely Q-Sepharose, packed...

  5. Solid reactors in sequential injection analysis: Recent trends in the environmental field

    DEFF Research Database (Denmark)

    Miró, Manuel; Hansen, Elo Harald

    2006-01-01

    -bead injection (SI-BI), used in either the jet-ring or lab-on-valve configurations, is presented as a front-end to many detectors. This article also outlines recent trends focused on exploiting SI as an automated tool for handling solid samples of environmental concern and accommodating dynamic fractionation...

  6. Determination of Low Level Concentrations of Metals by Means of Sequential Injection (SI) and Lab-on-Valve (LOV) Methodologies

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    packed with suitable materials, the emphasis in this lecture will be on applying solid-phase extraction in the SI/LOV mode. Providing unique characteristics and specific advantages, particularly allowing to take advantage of the so-called renewable approach, where the solid-phase material, if called for...

  7. Determination of Low Level Concentrations of Metals by Means of Sequential Injection (SI) and Lab-on-Valve (LOV) Methodologies

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Miró, Manuel; Petersen, Roongrat

    /emission spectrometry (FAAS, ETAAS, ICP-AES, ICP-MS). The lecture will initially give an overview of various automated alternatives for facilitating appropriate SI/LOV-separation and pre-concentration schemes of metals in liquid samples, including examples of solid-phase extraction with permanent columns or renewable...

  8. An automatic micro-sequential injection bead injection lab-on-valve (muSI-BI-LOV) assembly for speciation analysis of ultra trace levels of Cr(III) and Cr(VI) incorporating on-line chemical reduction and employing detection by electrothermal atomic absorption spectrometry (ETAAS)

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald

    2005-01-01

    and determination of trace levels of Cr(III) and Cr(VI) in environmental samples. The method was validated by determination of chromium species in CRM and NIST standard reference materials, and by spike recoveries of surface waters. Statistical comparison of means between experimental results and the total chromium...... certified values for the CRM and NIST materials revealed the non-existence of significant differences at a 95% confidence level....

  9. Universal approach for selective trace metal determinations via sequential injection-bead injection-lab-on-valve using renewable hydrophobic bead surfaces as reagent carriers

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald

    2005-01-01

    involves the use of poly(styrene-divinylbenzene) beads containing pendant octadecyl moieties (C18-PS/DVB), which are preimpregnated with a selective organic metal chelating agent prior to the automatic manipulation of the beads in the microbore conduits of the LOV unit. By adapting this approach...

  10. Micro solid phase spectrophotometry in a sequential injection lab-on-valve platform for cadmium, zinc, and copper determination in freshwaters.

    Science.gov (United States)

    Santos, Inês C; Mesquita, Raquel B R; Rangel, António O S S

    2015-09-03

    This work describes the development of a solid phase spectrophotometry method in a μSI-LOV system for cadmium, zinc, and copper determination in freshwaters. NTA (Nitrilotriacetic acid) beads with 60-160 μm diameter were packed in the flow cell of the LOV for a μSPE column of 1 cm length. The spectrophotometric determination is based on the colourimetric reaction between dithizone and the target metals, previously retained on NTA resin. The absorbance of the coloured product formed is measured, at 550 nm, on the surface of the NTA resin beads in a solid phase spectrophotometry approach. The developed method presented preconcentration factors in the range of 11-21 for the metal ions. A LOD of 0.23 μg L(-1) for cadmium, 2.39 μg L(-1) for zinc, and 0.11 μg L(-1) for copper and a sampling rate of 12, 13, and 15 h(-1) for cadmium, zinc, and copper were obtained, respectively. The proposed method was successfully applied to freshwater samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Micro solid phase spectrophotometry in a sequential injection lab-on-valve platform for cadmium, zinc, and copper determination in freshwaters

    International Nuclear Information System (INIS)

    Santos, Inês C.; Mesquita, Raquel B.R.; Rangel, António O.S.S.

    2015-01-01

    This work describes the development of a solid phase spectrophotometry method in a μSI-LOV system for cadmium, zinc, and copper determination in freshwaters. NTA (Nitrilotriacetic acid) beads with 60–160 μm diameter were packed in the flow cell of the LOV for a μSPE column of 1 cm length. The spectrophotometric determination is based on the colourimetric reaction between dithizone and the target metals, previously retained on NTA resin. The absorbance of the coloured product formed is measured, at 550 nm, on the surface of the NTA resin beads in a solid phase spectrophotometry approach. The developed method presented preconcentration factors in the range of 11–21 for the metal ions. A LOD of 0.23 μg L"−"1 for cadmium, 2.39 μg L"−"1 for zinc, and 0.11 μg L"−"1 for copper and a sampling rate of 12, 13, and 15 h"−"1 for cadmium, zinc, and copper were obtained, respectively. The proposed method was successfully applied to freshwater samples. - Highlights: • Multi-parametric determination of cadmium, zinc, and copper at the μg L"−"1 level. • In-line metal ions preconcentration using NTA resin. • Minimization of matrix interferences by performing solid phase spectrometry in a SI-LOV platform. • Successful application to metal ions determination in freshwaters.

  12. Micro solid phase spectrophotometry in a sequential injection lab-on-valve platform for cadmium, zinc, and copper determination in freshwaters

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Inês C. [CBQF–Centro de Biotecnologia e Química Fina – Laboratório Associado, Escola Superior de Biotecnologia, Universidade Católica Portuguesa/Porto, Rua Arquiteto Lobão Vital, Apartado 2511, 4202-401 Porto (Portugal); Mesquita, Raquel B.R. [CBQF–Centro de Biotecnologia e Química Fina – Laboratório Associado, Escola Superior de Biotecnologia, Universidade Católica Portuguesa/Porto, Rua Arquiteto Lobão Vital, Apartado 2511, 4202-401 Porto (Portugal); Laboratório de Hidrobiologia, Instituto de Ciências Biomédicas Abel Salazar (ICBAS), Universidade do Porto, Rua de Jorge Viterbo Ferreira no. 228, 4050-313 Porto (Portugal); Rangel, António O.S.S., E-mail: arangel@porto.ucp.pt [CBQF–Centro de Biotecnologia e Química Fina – Laboratório Associado, Escola Superior de Biotecnologia, Universidade Católica Portuguesa/Porto, Rua Arquiteto Lobão Vital, Apartado 2511, 4202-401 Porto (Portugal)

    2015-09-03

    This work describes the development of a solid phase spectrophotometry method in a μSI-LOV system for cadmium, zinc, and copper determination in freshwaters. NTA (Nitrilotriacetic acid) beads with 60–160 μm diameter were packed in the flow cell of the LOV for a μSPE column of 1 cm length. The spectrophotometric determination is based on the colourimetric reaction between dithizone and the target metals, previously retained on NTA resin. The absorbance of the coloured product formed is measured, at 550 nm, on the surface of the NTA resin beads in a solid phase spectrophotometry approach. The developed method presented preconcentration factors in the range of 11–21 for the metal ions. A LOD of 0.23 μg L{sup −1} for cadmium, 2.39 μg L{sup −1} for zinc, and 0.11 μg L{sup −1} for copper and a sampling rate of 12, 13, and 15 h{sup −1} for cadmium, zinc, and copper were obtained, respectively. The proposed method was successfully applied to freshwater samples. - Highlights: • Multi-parametric determination of cadmium, zinc, and copper at the μg L{sup −1} level. • In-line metal ions preconcentration using NTA resin. • Minimization of matrix interferences by performing solid phase spectrometry in a SI-LOV platform. • Successful application to metal ions determination in freshwaters.

  13. Sequential injection/bead injection lab-on-valve schemes for on-line solid phase extraction and preconcentration of ultra-trace levels of heavy metals with determination by ETAAS and ICPMS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald; Miró, Manuel

    2003-01-01

    are focused on the applications of SI-BI-LOV protocols for on-line microcolumn based solid phase extraction of ultra-trace levels of heavy metals, employing the so-called renewable surface separation and preconcentration manipulatory scheme. Two types of sorbents have been employed as packing material...

  14. Multisyringe flow injection lab-on-valve systems coupled to hydride generation atomic fluorescence spectrometry for on-line bead-injection preconcentration and determination of total inorganic arsenic in environmental waters

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Hansen, Elo Harald

    and 10% KI. The eluate merges downstream with a defined plug of sodium tetrahydroborate (0.3% w/v) for generation of arsine, which is subsequently quantified by AFS. An oxidation agent, namely 2x10-6 M potassium permanganate, was employed for the quantitative oxidation of As(III) to As(V) in the samples...

  15. Highly selective micro-sequential injection lab-on-valve (μSI-LOV) method for determination of ultra trace concentrations of nickel in saline matrices using detection by electrothermal atomic absorption spectrometr

    DEFF Research Database (Denmark)

    Long, Xiangbao; Miró, Manuel; Jensen, Rikard

    2006-01-01

    of the LOV to assure sufficient reaction time for the formation of Ni(DMG)2 chelate. The non-ionic coordination compound is then collected in a renewable micro-column packed with a reversed-phase copolymeric sorbent [namely, poly(divinylbenzene-co-N-vinylpyrrolidone)] containing a balanced ratio...... water of high hardness and local seawater. Satisfying recoveries were achieved for all spiked environmental water samples with maximum deviations of 6%. The experimental results for the standard reference material were not statistically different to the certified value at a significance level of 0.05....

  16. Automated injection of slurry samples in flow-injection analysis

    NARCIS (Netherlands)

    Hulsman, M.H.F.M.; Hulsman, M.; Bos, M.; van der Linden, W.E.

    1996-01-01

    Two types of injectors are described for introducing solid samples as slurries in flow analysis systems. A time-based and a volume-based injector based on multitube solenoid pinch valves were built, both can be characterized as hydrodynamic injectors. Reproducibility of the injections of dispersed

  17. Modified and reverse radiometric flow injection analysis

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Ba, H; Khin, M M; Aung, K; Thida, [Yangon Univ. (Myanmar). Dept. of Chemistry; Toelgyessy, J [Slovak Technical Univ., Bratislava (Slovakia). Dept. of Environmental Science

    1994-06-01

    Determination of [sup 137]Cs and [sup 60]Co by using modified and reverse radiometric flow injection analysis is described. Two component RFIA was also realized using [sup 60]Co and [sup 137]Cs radionuclides. (author) 2 refs.; 5 figs.

  18. Flow Injection Analysis in Industrial Biotechnology

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Miró, Manuel

    2009-01-01

    Flow injection analysis (FIA) is an analytical chemical continuous-flow (CF) method which in contrast to traditional CF-procedures does not rely on complete physical mixing (homogenisation) of the sample and the reagent(s) or on attaining chemical equilibria of the chemical reactions involved. Ex...

  19. Retro-review of flow injection analysis

    DEFF Research Database (Denmark)

    Ruzicka, Jaromir; Hansen, Elo Harald

    2008-01-01

    It is indeed unusual for authors to review their own monograph – J. Ruzicka, E.H. Hansen, Flow Injection Analysis, 2nd Edition, Wiley, Chichester, West Sussex, UK, 1988. – and even more so if the book was published 20 years ago. Yet such an exercise might yield a perspective on the progress of an...

  20. Warpage analysis in injection moulding process

    Science.gov (United States)

    Hidayah, M. H. N.; Shayfull, Z.; Nasir, S. M.; Fathullah, M.; Hazwan, M. H. M.

    2017-09-01

    This study was concentrated on the effects of process parameters in plastic injection moulding process towards warpage problem by using Autodesk Moldflow Insight (AMI) software for the simulation. In this study, plastic dispenser of dental floss has been analysed with thermoplastic material of Polypropylene (PP) used as the moulded material and details properties of 80 Tonne Nessei NEX 1000 injection moulding machine also has been used in this study. The variable parameters of the process are packing pressure, packing time, melt temperature and cooling time. Minimization of warpage obtained from the optimization and analysis data from the Design Expert software. Integration of Response Surface Methodology (RSM), Center Composite Design (CCD) with polynomial models that has been obtained from Design of Experiment (DOE) is the method used in this study. The results show that packing pressure is the main factor that will contribute to the formation of warpage in x-axis and y-axis. While in z-axis, the main factor is melt temperature and packing time is the less significant among the four parameters in x, y and z-axes. From optimal processing parameter, the value of warpage in x, y and z-axis have been optimised by 21.60%, 26.45% and 24.53%, respectively.

  1. Separation and preconcentration of ultratrace levels of cadmium(II) in a sequential injection (SI) system with a PTFE packed column as a mimic sequential injection lab-on-valve (SI-LOV) system with renewable column employing detection by electrothermal atomic absorption spectrometry (ETAAS)

    DEFF Research Database (Denmark)

    Long, Xiangbao; Chomchoei, Roongrat; Gała, Piotr

    of cadmium(II) by detection with electrothermal atomic absorption spectrometry (ETAAS). The non-charged complex formed between the analyste and the chelating reagent diethyldithiophosphate (DDPA) was selectively adsorbed on the surface of the PTFE beads and eluted by ethanol before being directed...

  2. Safety Injection Tank Performance Analysis Using CFD

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Oan; Lee, Jeong Ik; Nietiadi Yohanes Setiawan [KAIST, Daejeon (Korea, Republic of); Addad Yacine [KUSTAR, Abu Dhabi (United Arab Emirates); Bang, Young Seok; Yoo, Seung Hun [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2016-10-15

    This may affect the core cooling capability and threaten the fuel integrity during LOCA situations. However, information on the nitrogen flow rate during discharge is very limited due to the associated experimental measurement difficulties, and these phenomena are hardly reflected in current 1D system codes. In the current study, a CFD analysis is presented which hopefully should allow obtaining a more realistic prediction of the SIT performance which can then be reflected on 1D system codes to simulate various accident scenarios. Current Computational Fluid Dynamics (CFD) calculations have had limited success in predicting the fluid flow accurately. This study aims to find a better CFD prediction and more accurate modeling to predict the system performance during accident scenarios. The safety injection tank with fluidic device was analyzed using commercial CFD. A fine resolution grid was used to capture the vortex of the fluidic device. The calculation so far has shown good consistency with the experiment. Calculation should complete by the conference date and will be thoroughly analyzed to be discussed. Once a detailed CFD computation is finished, a small-scale experiment will be conducted for the given conditions. Using the experimental results and the CFD model, physical models can be validated to give more reliable results. The data from CFD and experiments will provide a more accurate K-factor of the fluidic device which can later be applied in system code inputs.

  3. COMBUSTION ANALYSIS OF A CNG DIRECT INJECTION SPARK IGNITION ENGINE

    Directory of Open Access Journals (Sweden)

    A. Rashid A. Aziz

    2010-12-01

    Full Text Available An experimental study was carried out on a dedicated compressed natural gas direct injection (CNG-DI engine with a compression ratio (CR of 14 and a central injection system. Several injection timing parameters from early injection timing (300 BTDC to partial direct injection (180 BTDC to full direct injection (120 BTDC were investigated. The 300 BTDC injection timing experiment was carried out to simulate the performance of a port injection engine and the result is used as a benchmark for engine performance. The full DI resulted in a 20% higher performance than the early injection timing for low engine speeds up to 2750 rpm. 180 BTDC injection timing shows the highest performance over an extensive range of engine speed because it has a similar volumetric efficiency to full DI. However, the earlier injection timing allowed for a better air–fuel mixing and gives superior performance for engine speeds above 4500 rpm. The engine performance could be explained by analysis of the heat release rate that shows that at low and intermediate engine speeds of 2000 and 3000, the full DI and partial DI resulted in the fastest heat release rate whereas at a high engine speed of 5000 rpm, the simulated port injection operation resulted in the fastest heat release rate.

  4. RELAP5 analysis of PACTEL injection tests

    International Nuclear Information System (INIS)

    Kimber, G.R.; Lillington, J.N.

    2000-01-01

    A characteristic feature of advanced reactor designs is their reliance on passive safety systems. It is important to assess both the operation of such systems and the ability of systems codes, such as RELAP5, to model them. In Finland VTT Energy, together with Lappeenranta University of Technology, is using the PACTEL facility for the investigation of passive core cooling systems. In particular, a core make-up tank (CMT) has been installed in the rig to operate in a similar manner to those in many Advanced PWR designs. Three small break tests, GDE-24, GDE-34 and GDE-43 in the PACTEL facility were chosen for modelling with RELAP5. The objective of GDE-24 was to investigate CMT behaviour and in particular the effects of condensation in the CMT. The second test, GDE-34, was similar except that it had a smaller CMT and at the start of the test the water in the CMT and connecting pipework was at an elevated temperature. Test GDE-43 focused on conditions when the driving force for flow through the passive system injection system (PSIS) slowly disappears. Analysis of all tests reported here was carried out with RELAP5/MOD 3.2.1.2. The paper summarises the conclusions of all the tests. A critical part of the study revolved around modelling of the CMT. A model was developed to allow its detailed behaviour to be investigated more easily. This enabled recommendations for improving the condensation modelling in RELAP5 to be made. Apart from the wall condensation modelling issue, the implication of the work is that RELAP5/MOD 3.2.1.2 (a comparatively recent version of the code) is broadly adequate for these applications. (author)

  5. Radiometric flow injection analysis with an ASIA (Ismatec) analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Win, N; San, K; Han, B; Myoe, K M [Yangon Univ. (Myanmar). Dept. of Chemistry; Toelgyessy, J [Slovak Technical Univ., Bratislava (Slovakia). Dept. of Environmental Science

    1994-07-01

    Radiometric Flow Injection Analysis of a radioactive ([sup 131]I) sample is described. For analysis an ASIA (Ismatec) analyzer with a NaI(Tl) scintillation detector was used. (author) 5 refs.; 3 figs.

  6. Thermodynamic analysis and numerical modeling of supercritical injection

    OpenAIRE

    Banuti, Daniel

    2015-01-01

    Although liquid propellant rocket engines are operational and have been studied for decades, cryogenic injection at supercritical pressures is still considered essentially not understood. This thesis intends to approach this problem in three steps: by developing a numerical model for real gas thermodynamics, by extending the present thermodynamic view of supercritical injection, and finally by applying these methods to the analysis of injection. A new numerical real gas thermodynamics mode...

  7. Analysis of Dynamic Characteristics of Water Injection Pump

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Myeong; Lee, Jeong Hoon; Ha, Jeong Min; Ahn, Byung Hyun; Kim, Won Cheol; Choi, Byeong Keun [Gyeongsang Nat' l Univ., Jinju (Korea, Republic of)

    2013-12-15

    Water injection pump outputs oil with high pressure during this process, seawater is injected into the well to recover the well pressure and maintain high productivity. A water injection pump has high productivity, and herefore, it serves as a key piece of equipment in marine plants. In this light, water injection pumps are being studied widely in industry. In this study, the rotor dynamics is analyzed to determine the natural frequency according to the bearing stiffness and operation speed change. This study aims to establish the pump reliability through critical speed, stability, and unbalance response analysis.

  8. CANDU 6 liquid injection shutdown system waterhammer analysis using PTRAN

    International Nuclear Information System (INIS)

    Ko, Deuk Yoon; Kim, Eun Ki; Ko, Yong Sang; Park, Byung Ho; Kim, Seok Bum

    1996-06-01

    An in-core LOCA could result in flooding of the helium header in the liquid injection shutdown system. Flooding of the helium header will result in severe pressure transients (waterhammer) in the liquid injection shutdown system when the shutdown signal is initiated. To evaluate the impact of the dynamic effects of this event, a pressure transient analysis has been performed. This analysis is performed using PTRAN, which is a computer program based on the method of characteristics. The results of this analysis are used in the stress analysis of the piping and pipe supports to ensure that the liquid injection shutdown system can withstand the pressure transient loadings. This analysis report documents the results of waterhammer analysis performed for the liquid injection shutdown system for the Wolsung nuclear power plant unit 2, 3 and 4. 4 tabs., 11 figs., 15 refs. (Author)

  9. CANDU 6 liquid injection shutdown system waterhammer analysis using PTRAN

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Deuk Yoon; Kim, Eun Ki; Ko, Yong Sang; Park, Byung Ho; Kim, Seok Bum [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-06-01

    An in-core LOCA could result in flooding of the helium header in the liquid injection shutdown system. Flooding of the helium header will result in severe pressure transients (waterhammer) in the liquid injection shutdown system when the shutdown signal is initiated. To evaluate the impact of the dynamic effects of this event, a pressure transient analysis has been performed. This analysis is performed using PTRAN, which is a computer program based on the method of characteristics. The results of this analysis are used in the stress analysis of the piping and pipe supports to ensure that the liquid injection shutdown system can withstand the pressure transient loadings. This analysis report documents the results of waterhammer analysis performed for the liquid injection shutdown system for the Wolsung nuclear power plant unit 2, 3 and 4. 4 tabs., 11 figs., 15 refs. (Author).

  10. Meta-Analysis of the Clinical Value of Danshen Injection and Huangqi Injection in Liver Cirrhosis

    Directory of Open Access Journals (Sweden)

    Changtai Zhu

    2013-01-01

    Full Text Available Objective. To evaluate the clinical value of Danshen injection and Huangqi injection for the treatment of liver cirrhosis. Methods. The Chinese Biomedical Literature Database (CBM, Chinese Scientific Journals Full-Text Database (VIP, Wanfang Database, China National Knowledge Infrastructure (CNKI, PubMed, and EMBASE database were searched to collect the literatures about the randomized controlled trials involving the treatment of liver cirrhosis with Danshen injection combined with Huangqi injection, and the data analyses were performed using RevMan 4.2 software. Results. A total of 11 studies involving 1086 patients (trials group: 554 cases, control group: 532 cases were included in this study. Compared with those in control group, the meta-analysis showed-that the total effectiveness rate and the level of serum albumin increased, while serum total bilirubin, alanine transmninase, type III procollagen, hyaluronic acid, laminin, and type-IV collagen decreased in trials group. The Jadad score ranged from 1 to 2 and the funnel plot analysis suggests that publication bias may occur. Conclusions. Danshen injection combined with Huangqi injection may promote the curative efficacy of liver cirrhosis, which is a promising novel treatment approach. The exact outcome needs to perform rigorously designed, multicenter, and large randomized controlled trials.

  11. CFD analysis of poison injection in AHWR calandria

    International Nuclear Information System (INIS)

    Kansal, A.K.; Kamble, M.T.; Maheshwari, N.K.; Vijayan, P.K.

    2014-01-01

    The present work intends to give details of design and performance validation of SDS-2. The performance is evaluated on the basis of dispersion of poison in calandria in a given period of time. Location of injection tube and injection holes, size of jet hole and number of holes are some of the design parameters which greatly affect dispersion of poison in calandria. A Computational Fluid Dynamic (CFD) study for axial and radial injection of poison was carried out using open source CFD code OpenFOAM. CFD benchmarking was done using experiments performed by Johari (Johari et al. 1997) to identify suitable turbulence model for this problem. An experimental facility simulating poison injection in moderator in presence of calandria tubes was used to further validate the CFD model is shown in the paper. CFD analysis was carried out for axial as well as radial injection for AHWR geometry. CFD analysis using OpenFOAM has been carried out to study high pressure poison injection for single jet of Shut Down System - 2 (SDS- 2) of Advanced Heavy Water Reactor (AHWR) for various design options. CFD model used in analysis have been validated with experimental data available in literature as well as experiments performed for AHWR specific geometry. Various turbulence models are tested and their adequacy for such flow problems has been established. The CFD model is then used to simulate poison injection for two design options for AHWR and their performance is compared. (author)

  12. Drug injecting and HIV risk among injecting drug users in Hai Phong, Vietnam: a qualitative analysis.

    Science.gov (United States)

    Ahmed, Tanvir; Long, Thanh Nguyen; Huong, Phan Thi; Stewart, Donald Edwin

    2015-01-29

    Hai Phong, located in northern Vietnam, has become a high HIV prevalence province among Injecting Drug Users (IDUs) since the infection shifted from the southern to the northern region of the country. Previous research indicates high levels of drug and sex related risk behaviour especially among younger IDUs. Our recent qualitative research provides a deeper understanding of HIV risk behaviour and highlights views and experiences of IDUs relating to drug injecting and sharing practices. Fifteen IDUs participated in semi-structured interviews conducted in September-October, 2012. Eligible participants were selected from those recruited in a larger scale behavioural research project and identified through screening questions. Interviews were conducted by two local interviewers in Vietnamese and were audiotaped. Ethical procedures, including informed consent and participants' understanding of their right to skip and withdraw, were applied. Transcripts were translated and double checked. The data were categorised and coded according to themes. Thematic analysis was conducted and a qualitative data analysis thematic framework was used. Qualitative analysis highlighted situational circumstances associated with HIV risks among IDUs in Hai Phong and revealed three primary themes: (i) places for injecting, (ii) injecting drugs in small groups, and (iii) sharing practices. Our results showed that shared use of jointly purchased drugs and group injecting were widespread among IDUs without adequate recognition of these as HIV risk behaviours. Frequent police raids generated a constant fear of arrest. As a consequence, the majority preferred either rail lines or isolated public places for injection, while some injected in their own or a friend's home. Price, a heroin crisis, and strong group norms encouraged collective preparation and group injecting. Risk practices were enhanced by a number of factors: the difficulty in getting new syringes, quick withdrawal management

  13. Thermodynamic analysis of steam-injected advanced gas turbine cycles

    Science.gov (United States)

    Pandey, Devendra; Bade, Mukund H.

    2017-12-01

    This paper deals with thermodynamic analysis of steam-injected gas turbine (STIGT) cycle. To analyse the thermodynamic performance of steam-injected gas turbine (STIGT) cycles, a methodology based on pinch analysis is proposed. This graphical methodology is a systematic approach proposed for a selection of gas turbine with steam injection. The developed graphs are useful for selection of steam-injected gas turbine (STIGT) for optimal operation of it and helps designer to take appropriate decision. The selection of steam-injected gas turbine (STIGT) cycle can be done either at minimum steam ratio (ratio of mass flow rate of steam to air) with maximum efficiency or at maximum steam ratio with maximum net work conditions based on the objective of plants designer. Operating the steam injection based advanced gas turbine plant at minimum steam ratio improves efficiency, resulting in reduction of pollution caused by the emission of flue gases. On the other hand, operating plant at maximum steam ratio can result in maximum work output and hence higher available power.

  14. Automated method for simultaneous lead and strontium isotopic analysis applied to rainwater samples and airborne particulate filters (PM10).

    Science.gov (United States)

    Beltrán, Blanca; Avivar, Jessica; Mola, Montserrat; Ferrer, Laura; Cerdà, Víctor; Leal, Luz O

    2013-09-03

    A new automated, sensitive, and fast system for the simultaneous online isolation and preconcentration of lead and strontium by sorption on a microcolumn packed with Sr-resin using an inductively coupled plasma mass spectrometry (ICP-MS) detector was developed, hyphenating lab-on-valve (LOV) and multisyringe flow injection analysis (MSFIA). Pb and Sr are directly retained on the sorbent column and eluted with a solution of 0.05 mol L(-1) ammonium oxalate. The detection limits achieved were 0.04 ng for lead and 0.03 ng for strontium. Mass calibration curves were used since the proposed system allows the use of different sample volumes for preconcentration. Mass linear working ranges were between 0.13 and 50 ng and 0.1 and 50 ng for lead and strontium, respectively. The repeatability of the method, expressed as RSD, was 2.1% and 2.7% for Pb and Sr, respectively. Environmental samples such as rainwater and airborne particulate (PM10) filters as well as a certified reference material SLRS-4 (river water) were satisfactorily analyzed obtaining recoveries between 90 and 110% for both elements. The main features of the LOV-MSFIA-ICP-MS system proposed are the capability to renew solid phase extraction at will in a fully automated way, the remarkable stability of the column which can be reused up to 160 times, and the potential to perform isotopic analysis.

  15. Deformation analysis considering thermal expansion of injection mold

    International Nuclear Information System (INIS)

    Kim, Jun Hyung; Yi, Dae Eun; Jang, Jeong Hui; Lee, Min Seok

    2015-01-01

    In the design of injection molds, the temperature distribution and deformation of the mold is one of the most important parameters that affect the flow characteristics, flash generation, and surface appearance, etc. Plastic injection analyses have been carried out to predict the temperature distribution of the mold and the pressure distribution on the cavity surface. As the input loads, we transfer the temperature and pressure results to the structural analysis. We compare the structural analysis results with the thermal expansion effect using the actual flash and step size of a smartphone cover part. To reduce the flash problem, we proposed a new mold design, and verified the results by performing simulations

  16. Deformation analysis considering thermal expansion of injection mold

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jun Hyung; Yi, Dae Eun; Jang, Jeong Hui; Lee, Min Seok [Samsung Electronics Co., LTD., Seoul (Korea, Republic of)

    2015-09-15

    In the design of injection molds, the temperature distribution and deformation of the mold is one of the most important parameters that affect the flow characteristics, flash generation, and surface appearance, etc. Plastic injection analyses have been carried out to predict the temperature distribution of the mold and the pressure distribution on the cavity surface. As the input loads, we transfer the temperature and pressure results to the structural analysis. We compare the structural analysis results with the thermal expansion effect using the actual flash and step size of a smartphone cover part. To reduce the flash problem, we proposed a new mold design, and verified the results by performing simulations.

  17. ANALYSIS OF HARMONIC INJECTION TO THE MODULATION OF ...

    African Journals Online (AJOL)

    2013-03-01

    Mar 1, 2013 ... Abstract. This paper explores the analysis of third and ninth harmonic injection to the modulation of a multi- level diode clamped converter (DCC) at a varying modulation index. The spectral distributions of the various multi-level waveforms obtained under normal modulation index of 0.8 and over modulation ...

  18. Flow Injection Analysis: A Revolution in Modern Analytical Chemistry

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    1996-01-01

    A review is made of the fundamentals of Flow Injection Analysis (FIA), and the versatility and applicability of this analytical concept is demonstrated by a series of examples, comprizing the use of different types of FIA-manifolds and various detection devices (optical and electrochemical...

  19. Flow injection analysis in inductively coupled plasma spectrometry

    International Nuclear Information System (INIS)

    Rosias, Maria F.G.G.

    1995-10-01

    The main features of flow injection analysis (FIA) as contribution to the inductively coupled plasma (Icp) spectrometry are described. A systematic review of researches using the combined FIA-Icp and the benefits of this association are presented. Flow systems were proposed to perform on-line Icp solution management for multielemental determination by atomic emission spectrometry (Icp-AES) or mass spectrometry. The inclusion of on-line ion exchangers in flow systems for matrix separation and/or analyte preconcentration are presented. Together with those applications the new advent of instruments with facilities for multielement detection on flow injection signals are described. (author). 75 refs., 19 figs

  20. Separate direct injection of diesel and ethanol: A numerical analysis

    Directory of Open Access Journals (Sweden)

    Burnete Nicolae V.

    2017-01-01

    Full Text Available The purpose of this study is to investigate the theoretical possibility of using a pilot diesel injection for the auto-ignition of a main ethanol injection in a compression ignition engine. To this effect a predictive simulation model has been built based on experimental results for a diesel cycle (pilot and main injection at 1500 and 2500 min–1, respectively. For every engine speed, in addition to the diesel reference cycle, two more simulations were done: one with the same amount of fuel injected into the cylinder and one with the same amount of energy, which required an increase in the quantity of ethanol proportional to the ratio of its lower heating value and that of diesel. The simulations showed that in all cases the pilot diesel led to the auto-ignition of ethanol. The analysis of the in-cylinder traces at 1500 min–1 showed that combustion efficiency is improved, the peak temperature value decrease with approximately 240 K and, as a result, the NO emissions are 3.5-4 times lower. The CO and CO2 values depend on the amount of fuel injected into the cylinder. At 2500 min–1 there are similar trends but with the following observations: the ignition delay increases, while the pressure and temperature are lower.

  1. Development of flow injection analysis technique for uranium estimation

    International Nuclear Information System (INIS)

    Paranjape, A.H.; Pandit, S.S.; Shinde, S.S.; Ramanujam, A.; Dhumwad, R.K.

    1991-01-01

    Flow injection analysis is increasingly used as a process control analytical technique in many industries. It involves injection of the sample at a constant rate into a steady flowing stream of reagent and passing this mixture through a suitable detector. This paper describes the development of such a system for the analysis of uranium (VI) and (IV) and its gross gamma activity. It is amenable for on-line or automated off-line monitoring of uranium and its activity in process streams. The sample injection port is suitable for automated injection of radioactive samples. The performance of the system has been tested for the colorimetric response of U(VI) samples at 410 nm in the range of 35 to 360mg/ml in nitric acid medium using Metrohm 662 Photometer and a recorder as detector assembly. The precision of the method is found to be better than +/- 0.5%. This technique with certain modifications is used for the analysis of U(VI) in the range 0.1-3mg/ailq. by alcoholic thiocynate procedure within +/- 1.5% precision. Similarly the precision for the determination of U(IV) in the range 15-120 mg at 650 nm is found to be better than 5%. With NaI well-type detector in the flow line, the gross gamma counting of the solution under flow is found to be within a precision of +/- 5%. (author). 4 refs., 2 figs., 1 tab

  2. Analysis of BSRT Profiles in the LHC at Injection

    CERN Document Server

    Fitterer, M; Papadopoulou, S; Papaphilippou, Y; Redaelli, S

    2017-01-01

    The beam synchrotron radiation telescope (BSRT) at the LHC allows to take profiles of the transverse beam distribution, which can provide useful additional insight in the evolution of the transverse beam distribution. A python class has been developed [1], which allows to read in the BSRT profiles, usually stored in binary format, run different analysis tools and generate plots of the statistical parameters and profiles as well as videos of the the profiles. The detailed analysis will be described in this note. The analysis is based on the data obtained at injection energy (450 GeV) during MD1217 [2] and MD1415 [3] which will be also used as illustrative example. A similar approach is also taken with a MATLAB based analysis described in [4].

  3. Multidose Botulinum Toxin A for Intralaryngeal Injection: A Cost Analysis.

    Science.gov (United States)

    Gilbert, Mark R; Young, VyVy N; Smith, Libby J; Rosen, Clark A

    2018-01-04

    Botulinum toxin A (BtxA) injection is the mainstay treatment for laryngeal dystonias. BtxA product labeling states that reconstituted toxin should be used within 4 hours on a single patient despite several studies that have demonstrated multidose BtxA to be safe and effective. Many insurance carriers mandate the use of an outside pharmacy which necessitates a single-use approach. This study compares the cost savings of multidose BtxA for laryngeal dystonia compared to single-use. This is a retrospective review and projected cost savings analysis. Records and billing information were reviewed for patients receiving BtxA for intralaryngeal injection at a single laryngology division in 2015. Inclusion criteria included CPT 64617 or J0585; exclusion criteria included CPT 64616. The price of BtxA 100 unit vial for calculation was $670. A total of 142 patients were seen for intralaryngeal BtxA injection resulting in 337 visits over 1 year. The average BtxA dose per visit was 2.86 units with an average of 3.06 procedure visits per year. The calculated cost of BtxA treatment using a single vial approach was found to be $2,050 per patient per year. If billed instead for $7/unit with 5 units wastage charge per visit, the yearly per patient charge is $168. Single vial-use of BtxA injection thus represents a 1,118% price increase versus multidose use. When estimated for yearly prevalence of spasmodic dysphonia, multidose BtxA use would save almost $100 million annually. Multidose botulinum toxin A application utilizing per unit billing is significantly less expensive than per single-use vial billing and would save the health-care system significant amount of money without any sacrifice in safety or effectiveness. Copyright © 2018. Published by Elsevier Inc.

  4. Spectrofluorimetric determination of cerium by flow injection analysis

    International Nuclear Information System (INIS)

    Liu Shaorong; Meng Jian; Liu Wenhua

    1990-01-01

    A spectrofluorimetric method for the determination of cerium (λ ex/em:251/365 nm) in hydrochloric acid solution by flow injection analysis is presented. It has well developed the normal spectrofluorimetric method for determination of cerium and has made: 1, the determination procedure shortened; 2, the determination speed increased to about 180 samples per hour; 3, the determination range widened to 0.05-100.0 ppm CeO 2 , abouot two times as wide as the normal spectrofluorimetric method; and 4, the relative standard deviation lessened (about 0.47% for 0.1 ppm CeO 2 , n = 13)

  5. Hydrogen ion species analysis and related neutral beam injection power assessment in the Heliotron E neutral beam injection system

    International Nuclear Information System (INIS)

    Sano, Fumimichi; Obiki, Tokuhiro; Sasaki, Akihiko; Iiyoshi, Atsuo; Uo, Koji

    1982-01-01

    The hydrogen ion species in a Heliotron E neutral beam injection system of maximum electric power 6.3 MW were analyzed in order to assess the neutral beam power injected into the torus. The masimum p roton ratio of the cylindrical bucket type ion source used was observed to be more than 90 percent assuming that the angular divergences for the respective species in the beam are the same. The experimental data are compared with calculations using a particle balance model. The analysis indicates that the net injection power reaches nearly 2.7 MW at the optimal conditions of the system considering the geometrical limitation of the neutral beam path. (author)

  6. Flow injection analysis: Emerging tool for laboratory automation in radiochemistry

    International Nuclear Information System (INIS)

    Egorov, O.; Ruzicka, J.; Grate, J.W.; Janata, J.

    1996-01-01

    Automation of routine and serial assays is a common practice of modern analytical laboratory, while it is virtually nonexistent in the field of radiochemistry. Flow injection analysis (FIA) is a general solution handling methodology that has been extensively used for automation of routine assays in many areas of analytical chemistry. Reproducible automated solution handling and on-line separation capabilities are among several distinctive features that make FI a very promising, yet under utilized tool for automation in analytical radiochemistry. The potential of the technique is demonstrated through the development of an automated 90 Sr analyzer and its application in the analysis of tank waste samples from the Hanford site. Sequential injection (SI), the latest generation of FIA, is used to rapidly separate 90 Sr from interfering radionuclides and deliver separated Sr zone to a flow-through liquid scintillation detector. The separation is performed on a mini column containing Sr-specific sorbent extraction material, which selectively retains Sr under acidic conditions. The 90 Sr is eluted with water, mixed with scintillation cocktail, and sent through the flow cell of a flow through counter, where 90 Sr radioactivity is detected as a transient signal. Both peak area and peak height can be used for quantification of sample radioactivity. Alternatively, stopped flow detection can be performed to improve detection precision for low activity samples. The authors current research activities are focused on expansion of radiochemical applications of FIA methodology, with an ultimate goal of creating a set of automated methods that will cover the basic needs of radiochemical analysis at the Hanford site. The results of preliminary experiments indicate that FIA is a highly suitable technique for the automation of chemically more challenging separations, such as separation of actinide elements

  7. Outcome analysis of two different injection solutions for epidural injection in radicular lumbar backache syndromes

    International Nuclear Information System (INIS)

    Saqib, M.; Mukhtar, M.; Bhatti, S.N; Afridi, E.A.K.; Khan, R.

    2017-01-01

    Background: Backache is a significant source of disability and suffering in our society. The treatment modalities need continued enhancement in order to achieve the desired goals of lowering morbidity and financial losses while improving the response of the patient. Methods: This prospective comparative study was conducted at the department of Orthopaedics and Spine Surgery, Khyber Teaching Hospital Peshawar from July 2013 to June 2015. Two interventional groups were designated; Group 1 was comprised of 54 patients who were injected with epidural bupivacaine plus methylprednisolone while Group 2 included 55 patients who were injected with bupivacaine only. Outcome was assessed using the visual analogue scale and Oswestry disability index (ODI). Results: Fifty-five female and 54 male patients with mean age 49.37 years+-10.46 SD, Mean symptoms duration was 15.01 months+-9.32 SD. Common presenting symptoms were backache (77.1 percent), lower limbs pain (66.1 percent), dermatomal paresthesias (54.1 percent) and neurogenic claudication in 57.8 percent patients. The mean visual analogue score (VAS) after injection was 3.18+-1.29 while mean ODI after injection was 23.615. There was a statistically significant reduction in VAS scores (2-sided p=0.003, OR =4.03, 95 percent CI: 1.535-10.60) following the injection. Conclusion: An epidural spinal injection is a viable option for achieving relief of pain and improves functioning in individuals with radicular backache. However, further research is advised in order to clarify the role of ESI for long-term relief. (author)

  8. Development of devices for self-injection: using tribological analysis to optimize injection force

    Directory of Open Access Journals (Sweden)

    Lange J

    2016-05-01

    Full Text Available Jakob Lange, Leos Urbanek, Stefan BurrenYpsomed Delivery Systems, Ypsomed AG, Burgdorf, Switzerland Abstract: This article describes the use of analytical models and physical measurements to characterize and optimize the tribological behavior of pen injectors for self-administration of biopharmaceuticals. One of the main performance attributes of this kind of device is its efficiency in transmitting the external force applied by the user on to the cartridge inside the pen in order to effectuate an injection. This injection force characteristic is heavily influenced by the frictional properties of the polymeric materials employed in the mechanism. Standard friction tests are available for characterizing candidate materials, but they use geometries and conditions far removed from the actual situation inside a pen injector and thus do not always generate relevant data. A new test procedure, allowing the direct measurement of the coefficient of friction between two key parts of a pen injector mechanism using real parts under simulated use conditions, is presented. In addition to the absolute level of friction, the test method provides information on expected evolution of friction over lifetime as well as on expected consistency between individual devices. Paired with an analytical model of the pen mechanism, the frictional data allow the expected overall injection system force efficiency to be estimated. The test method and analytical model are applied to a range of polymer combinations with different kinds of lubrication. It is found that material combinations used without lubrication generally have unsatisfactory performance, that the use of silicone-based internal lubricating additives improves performance, and that the best results can be achieved with external silicone-based lubricants. Polytetrafluoroethylene-based internal lubrication and external lubrication are also evaluated but found to provide only limited benefits unless used in

  9. Performance Analysis of Multi Stage Safety Injection Tank

    International Nuclear Information System (INIS)

    Shin, Soo Jai; Kim, Young In; Bae, Youngmin; Kang, Han-Ok; Kim, Keung Koo

    2015-01-01

    In general the integral reactor has such characteristics, the integral reactor requires a high flow rate of coolant safety injection at the initial stage of the accident in which the core level is relatively fast decreased, A medium flow rate of coolant safety injection at the early and middle stages of the accident in which the coolant discharge flow rate is relatively large due to a high internal pressure of the reactor vessel, and a low flow rate of coolant safety injection is required at the middle and late stages of the accident in which the coolant discharge flow rate is greatly reduced due to a decreased pressure of the reactor vessel. It is noted that a high flow rate of the integral reactor is quite smaller compared to a flow rate required in the commercial loop type reactor. However, a nitrogen pressurized safety injection tank has been typically designed to quickly inject a high flow rate of coolant when the internal pressure of the reactor vessel is rapidly decreased, and a core makeup tank has been designed to safely inject at a single mode flow rate due to a gravitational head of water subsequent to making a pressure balance between the reactor vessel and core makeup tank. As a result, in order to compensate such a disadvantage, various type systems are used in a complicated manner in a reactor according to the required characteristic of safety injection during an accident. In the present study, we have investigated numerically the performance of the multi stage safety injection tank. A parameter study has performed to understand the characteristics of the multi stage safety injection tank. The performance of the multi stage safety injection tank has been investigated numerically. When an accident occurs, the coolant in the multi stage safety injection tank is injected into a reactor vessel by a gravitational head of water subsequent to making a pressure balance between the reactor and tank. At the early stages of the accident, the high flow rate of

  10. Performance Analysis of Multi Stage Safety Injection Tank

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Soo Jai; Kim, Young In; Bae, Youngmin; Kang, Han-Ok; Kim, Keung Koo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In general the integral reactor has such characteristics, the integral reactor requires a high flow rate of coolant safety injection at the initial stage of the accident in which the core level is relatively fast decreased, A medium flow rate of coolant safety injection at the early and middle stages of the accident in which the coolant discharge flow rate is relatively large due to a high internal pressure of the reactor vessel, and a low flow rate of coolant safety injection is required at the middle and late stages of the accident in which the coolant discharge flow rate is greatly reduced due to a decreased pressure of the reactor vessel. It is noted that a high flow rate of the integral reactor is quite smaller compared to a flow rate required in the commercial loop type reactor. However, a nitrogen pressurized safety injection tank has been typically designed to quickly inject a high flow rate of coolant when the internal pressure of the reactor vessel is rapidly decreased, and a core makeup tank has been designed to safely inject at a single mode flow rate due to a gravitational head of water subsequent to making a pressure balance between the reactor vessel and core makeup tank. As a result, in order to compensate such a disadvantage, various type systems are used in a complicated manner in a reactor according to the required characteristic of safety injection during an accident. In the present study, we have investigated numerically the performance of the multi stage safety injection tank. A parameter study has performed to understand the characteristics of the multi stage safety injection tank. The performance of the multi stage safety injection tank has been investigated numerically. When an accident occurs, the coolant in the multi stage safety injection tank is injected into a reactor vessel by a gravitational head of water subsequent to making a pressure balance between the reactor and tank. At the early stages of the accident, the high flow rate of

  11. Geomechanics-Based Stochastic Analysis of Injection- Induced Seismicity

    Energy Technology Data Exchange (ETDEWEB)

    Ghassemi, Ahmad [Univ. of Oklahoma, Norman, OK (United States)

    2017-08-21

    The production of geothermal energy from dry and low permeability reservoirs is achieved by water circulation in natural and/or man-made fractures, and is referred to as enhanced or engineered geothermal systems (EGS). Often, the permeable zones have to be created by stimulation, a process which involves fracture initiation and/or activation of discontinuities such as faults and joints due to pore pressure and the in-situ stress perturbations. The stimulation of a rock mass is often accompanied by multiple microseismic events. Micro-seismic events associated with rock failure in shear, and shear slip on new or pre-existing fracture planes and possibly their propagations. The microseismic signals contain information about the sources of energy that can be used for understanding the hydraulic fracturing process and the created reservoir properties. Detection and interpretation of microseismic events is useful for estimating the stimulated zone, created reservoir permeability and fracture growth, and geometry of the geological structures and the in-situ stress state. The process commonly is referred to as seismicity-based reservoir characterization (SBRC). Although, progress has been made by scientific & geothermal communities for quantitative and qualitative analysis of reservoir stimulation using SBRC several key questions remain unresolved in the analysis of micro-seismicity namely, variation of seismic activity with injection rate, delayed micro-seismicity, and the relation of stimulated zone to the injected volume and its rate, and the resulting reservoir permeability. In addition, the current approach to SBRC does not consider the full range of relevant poroelastic and thermoelastic phenomena and neglects the uncertainty in rock properties and in-situ stress in the data inversion process. The objective of this research and technology developments was to develop a 3D SBRC model that addresses these shortcomings by taking into account hydro

  12. Analysis for Passive Safety Injection of IPSS in Various LOCAs

    International Nuclear Information System (INIS)

    Kim, Sangho; Chang, Soonheung

    2013-01-01

    The Fukushima accident shows US the possibility of accidents that are beyond a designed imagination. Lots of lessons can be shortly summarized into three issues. First of all, the original cause was the occurrence of a Station Black-Out (SBO). Even if engineers considered the possibility of a loss of offsite power enough to be managed, the failure of EDGs seemed to be unnoticed. The second is poor operation and accident management. They could not understand the overall system and did not check the availability of alternating systems. The third is the large release of radioactive materials outside the containment. Even if SBO occurred and the accident was not managed well, all the means must have prevented the large release out of containment. After that, lots of problems were pointed and numerous actions were carried out in each country. The representative proposals are AAC, additional physical barrier, bunker concept and large big tank. Integrated passive safety system (IPSS) was proposed as one of the solutions for enhancing the safety. IPSS can cope with a SBO and accidents with a SBO. IPSS has five functions which are passive decay heat removal, passive safety injection, passive containment cooling, passive in-vessel retention and filtered venting system. The results showed a high performance of removing decay heat through steam generator cooling by forming natural circulation in the primary circuit. The design concept of passive safety injection system (PSIS) consists of the injection line from integrated passive safety tank (IPST) to reactor vessel. The previous works were only focused on a double ended guillotine break LOCA in SBO. The purpose of this paper is to analyze the performance of PSIS in IPSS for various LOCAs by using MARS (Multi-dimensional Analysis of Reactor Safety) code. The simulated accidents were LOCAs which were accompanied with a SBO. The conditions of the LOCAs were varied only for the size of break. It shall show the capability of PSIS

  13. Clinical and economic analysis of rescue intracytoplasmic sperm injection cycles.

    Science.gov (United States)

    Shalom-paz, Einat; Alshalati, Jana; Shehata, Fady; Jimenez, Luis; Son, Weon-Young; Holzer, Hananel; Tan, Seang Lin; Almog, Benny

    2011-12-01

    To identify clinical and embryological factors that may predict success in rescue intracytoplasmic sperm injection (ICSI) cycles (after total fertilization failure has occurred) and to evaluate the cost effectiveness of rescue ICSI strategy. Additionally, follow-up of 20 rescue ICSI pregnancies is reported. Retrospective analysis of total fertilization failure cycles. University-based tertiary medical center. In total, 92 patients who had undergone conventional in-vitro fertilization (IVF) cycles with total fertilization failure were included. The patients were divided into two subgroups: those who conceived through rescue ICSI and those who did not. The pregnant members of the rescue ICSI subgroup were found to be significantly younger (32.9 ± 4.2 vs. 36.3 ± 4.5, respectively, p = 0.0035,) and to have better-quality embryos than those who did not conceive (cumulative embryo score: 38.3 ± 20.4 vs. 29.3 ± 14.7, p = 0.025). Cost effectiveness analysis showed 25% reduction in the cost per live birth when rescue ICSI is compared to cycle cancellation approach. The pregnancies follow-up did not show adverse perinatal outcome. Rescue ICSI is an option for salvaging IVF cycles complicated by total fertilization failure. Success in rescue ICSI was found to be associated with younger age and higher quality of embryos. Furthermore, the cost effectiveness of rescue ICSI in terms of total fertilization failure was found to be worthwhile.

  14. Remote calorimetric detection of urea via flow injection analysis.

    Science.gov (United States)

    Gaddes, David E; Demirel, Melik C; Reeves, W Brian; Tadigadapa, Srinivas

    2015-12-07

    The design and development of a calorimetric biosensing system enabling relatively high throughput sample analysis are reported. The calorimetric biosensor system consists of a thin (∼20 μm) micromachined Y-cut quartz crystal resonator (QCR) as a temperature sensor placed in close proximity to a fluidic chamber packed with an immobilized enzyme. Layer by layer enzyme immobilization of urease is demonstrated and its activity as a function of the number of layers, pH, and time has been evaluated. This configuration enables a sensing system where a transducer element is physically separated from the analyte solution of interest and is thereby free from fouling effects typically associated with biochemical reactions occuring on the sensor surface. The performance of this biosensing system is demonstrated by detection of 1-200 mM urea in phosphate buffer via a flow injection analysis (FIA) technique. Miniaturized fluidic systems were used to provide continuous flow through a reaction column. Under this configuration the biosensor has an ultimate resolution of less than 1 mM urea and showed a linear response between 0-50 mM. This work demonstrates a sensing modality in which the sensor itself is not fouled or contaminated by the solution of interest and the enzyme immobilized Kapton® fluidic reaction column can be used as a disposable cartridge. Such a system enables reuse and reliability for long term sampling measurements. Based on this concept a biosensing system is envisioned which can perform rapid measurements to detect biomarkers such as glucose, creatinine, cholesterol, urea and lactate in urine and blood continuously over extended periods of time.

  15. Flow Injection/Sequential Injection Analysis Systems: Potential Use as Tools for Rapid Liver Diseases Biomarker Study

    Directory of Open Access Journals (Sweden)

    Supaporn Kradtap Hartwell

    2012-01-01

    Full Text Available Flow injection/sequential injection analysis (FIA/SIA systems are suitable for carrying out automatic wet chemical/biochemical reactions with reduced volume and time consumption. Various parts of the system such as pump, valve, and reactor may be built or adapted from available materials. Therefore the systems can be at lower cost as compared to other instrumentation-based analysis systems. Their applications for determination of biomarkers for liver diseases have been demonstrated in various formats of operation but only a few and limited types of biomarkers have been used as model analytes. This paper summarizes these applications for different types of reactions as a guide for using flow-based systems in more biomarker and/or multibiomarker studies.

  16. Study on mixed analysis method for fatigue analysis of oblique safety injection nozzle on main piping

    International Nuclear Information System (INIS)

    Lu Xifeng; Zhang Yixiong; Ai Honglei; Wang Xinjun; He Feng

    2014-01-01

    The simplified analysis method and the detailed analysis method were used for the fatigue analysis of the nozzle on the main piping. Because the structure of the oblique safety injection nozzle is complex and some more severe transients are subjected. The results obtained are more penalized and cannot be validate when the simplified analysis method used for the fatigue analysis. It will be little conservative when the detailed analysis method used, but it is more complex and time-consuming and boring labor. To reduce the conservatism and save time, the mixed analysis method which combining the simplified analysis method with the detailed analysis method is used for the fatigue analysis. The heat transfer parameters between the fluid and the structure which used for analysis were obtained by heat transfer property experiment. The results show that the mixed analysis which heat transfer property is considered can reduce the conservatism effectively, and the mixed analysis method is a more effective and practical method used for the fatigue analysis of the oblique safety injection nozzle. (authors)

  17. Analysis of pulsed injection for microgravity receiver tank chilldown

    Science.gov (United States)

    Honkonen, Scott C.; Pietrzyk, Joe R.; Schuster, John R.

    The dominant heat transfer mechanism during the hold phase of a tank chilldown cycle in a low-gravity environment is due to fluid motion persistence following the charge. As compared to the single-charge per vent cycle case, pulsed injection maintains fluid motion and the associated high wall heat transfer coefficients during the hold phase. As a result, the pulsed injection procedure appears to be an attractive method for reducing the time and liquid mass required to chill a tank. However, for the representative conditions considered, no significant benefit can be realized by using pulsed injection as compared to the single-charge case. A numerical model of the charge/hold/vent process was used to evaluate the pulsed injection procedure for tank chilldown in microgravity. Pulsed injection results in higher average wall heat transfer coefficients during the hold, as compared to the single-charge case. However, these high levels were not coincident with the maximum wall-to-fluid temperature differences, as in the single-charge case. For representative conditions investigated, the charge/hold/vent process is very efficient. A slightly shorter chilldown time was realized by increasing the number of pulses.

  18. Analysis on inflowing of the injecting Water in faulted formation

    Directory of Open Access Journals (Sweden)

    Ji Youjun

    2015-06-01

    Full Text Available As to low permeability reservoir, faults and fractures have a significant impact on effect of water injection and may lead up to the lower efficiency of oil displacement, which will bring about low efficiency of injecting water, and the intended purpose of improving recovery factor by water injection will not be reached. In order to reveal the mechanism for channeling of injecting water, research work is conducted as follows: First of all, based on seepage mechanics, fluid mechanics, rock mass mechanics, and multifield coupling theory, the mathematical model considering fluid–solid coupling of water-flooding development for low permeability reservoir is established, the numerical solution of the coupling model is obtained, and by creating an interface program between the seepage simulation procedure and stress computation program, we set up a feasible method to simulate the process of development of reservoir considering deformation of reservoir stratum; second, some cores are selected to test the stress sensitivity of rock in reservoir, and the relation of permeability and stress is proposed to connect the field parameters of the coupling model; finally, taking the S11 block of Daqing Oilfield, for instance, the seepage field and deformation of reservoir stratum is analyzed, and then the mechanism for leakage of injecting water in this block is given out, and the advice for adjustment of injection–production scheme in the future development stage is provided.

  19. Vibration analysis of the Golfech 2 safety injection system

    International Nuclear Information System (INIS)

    Morilhat, P.

    1993-01-01

    The main function of the safety injection system in a PWR plant is to ensure cooling of fuel elements in the event of a loss of coolant accident. The multistage centrifugal pump mounted-on this system induces pressure fluctuations, resulting in dynamic loads on piping. In certain plant units, these loads have caused cracking in the nozzles connected to the safety injection system, whereas in others, no damage has been observed. In order to understand the differences in dynamic behavior observed from one site to another, tests were performed on a real safety injection system, that of Golfech-2. They enabled determination of the modal characteristics of the system and identification of the hydro-acoustic source of the low head safety injection pump. They also enabled assessment of the pressure fluctuation levels in the pump suction and discharge areas as well as the vibratory response of the system when operating under partial and nominal flow conditions. Finally, these test results were used to estimate fatigue damage in the safety injection system. The experimental results will later be used to validate the model of the system undertaken with the piping design code CIRCUS and define the boundary conditions to be taken into account. (author). 6 figs., 2 refs

  20. Computational Fluid Dynamics Analysis of High Injection Pressure Blended Biodiesel

    Science.gov (United States)

    Khalid, Amir; Jaat, Norrizam; Faisal Hushim, Mohd; Manshoor, Bukhari; Zaman, Izzuddin; Sapit, Azwan; Razali, Azahari

    2017-08-01

    Biodiesel have great potential for substitution with petrol fuel for the purpose of achieving clean energy production and emission reduction. Among the methods that can control the combustion properties, controlling of the fuel injection conditions is one of the successful methods. The purpose of this study is to investigate the effect of high injection pressure of biodiesel blends on spray characteristics using Computational Fluid Dynamics (CFD). Injection pressure was observed at 220 MPa, 250 MPa and 280 MPa. The ambient temperature was kept held at 1050 K and ambient pressure 8 MPa in order to simulate the effect of boost pressure or turbo charger during combustion process. Computational Fluid Dynamics were used to investigate the spray characteristics of biodiesel blends such as spray penetration length, spray angle and mixture formation of fuel-air mixing. The results shows that increases of injection pressure, wider spray angle is produced by biodiesel blends and diesel fuel. The injection pressure strongly affects the mixture formation, characteristics of fuel spray, longer spray penetration length thus promotes the fuel and air mixing.

  1. CFD Analysis of the Safety Injection Tank and Fluidic Device

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Oan; Nietiadi, Yohanes Setiawan; Lee, Jeong Ik [KAIST, Daejeon (Korea, Republic of); Addad, Yacine [KUSTAR, Abu Dhabi (United Arab Emirates)

    2016-05-15

    One of the most important components in the ECCS is the safety injection tank (SIT). Inside the SIT, a fluidic device is installed, which passively controls the mass flow of the safety injection and eliminates the need for low pressure safety injection pumps. As more passive safety mechanisms are being pursued, it has become more important to understand flow structure and the loss mechanism within the fluidic device. Current computational fluid dynamics (CFD) calculations have had limited success in predicting the fluid flow accurately. This study proposes to find a more exact result using CFD and more realistic modeling to predict the performance during accident scenarios more accurately. The safety injection tank with fluidic device was analyzed thoroughly using CFD. The preliminary calculation used 60,000 meshes for the initial test calculation. The results fit the experimental results surprisingly despite its coarse grid. Nonetheless, the mesh resolution was increased to capture the vortex in the fluidic device precisely. Once a detailed CFD computation is finished, a small-scale experiment will be conducted for the given conditions. Using the experimental results and the CFD model, physical models can be improved to fit the results more accurately.

  2. Detailed Analysis of Torque Ripple in High Frequency Signal Injection based Sensor less PMSM Drives

    Directory of Open Access Journals (Sweden)

    Ravikumar Setty A.

    2017-01-01

    Full Text Available High Frequency Signal Injection based techniques are robust and well proven to estimate the rotor position from stand still to low speed. However, Injected high frequency signal introduces, high frequency harmonics in the motor phase currents and results in significant Output Torque ripple. There is no detailed analysis exist in the literature, to study the effect of injected signal frequency on Torque ripple. Objective of this work is to study the Torque Ripple resulting from High Frequency signal injection in PMSM motor drives. Detailed MATLAB/Simulink simulations are carried to quantify the Torque ripple at different Signal frequencies.

  3. Adaptive Injection-locking Oscillator Array for RF Spectrum Analysis

    International Nuclear Information System (INIS)

    Leung, Daniel

    2011-01-01

    A highly parallel radio frequency receiver using an array of injection-locking oscillators for on-chip, rapid estimation of signal amplitudes and frequencies is considered. The oscillators are tuned to different natural frequencies, and variable gain amplifiers are used to provide negative feedback to adapt the locking band-width with the input signal to yield a combined measure of input signal amplitude and frequency detuning. To further this effort, an array of 16 two-stage differential ring oscillators and 16 Gilbert-cell mixers is designed for 40-400 MHz operation. The injection-locking oscillator array is assembled on a custom printed-circuit board. Control and calibration is achieved by on-board microcontroller.

  4. Analysis and design of double-anode magnetron injection gun

    International Nuclear Information System (INIS)

    Yang Tie; Niu Xinjian; Liu Yinghui

    2013-01-01

    Based on electro-optical theory and adiabatic compression theory, a double-anode magnetic injection gun for TE 34,19 , 170 GHz gyrotron was analyzed and designed with EGUN software. Concerning with the factors such as positions of anode and magnetic field distance between anodes, we obtained the result that the velocity ratio of electron beam approximated 1.3, and the velocity spread was under 3%. Furthermore, we found that electron beam was sensitive with these factors, such as that the velocity ratio decreased when the distance between anodes increased, while the velocity spread decreased first and then increased. The double-anode magnetic injection gun is employed in the experiments of gyrotron. (authors)

  5. Magnetic error analysis of recycler pbar injection transfer line

    Energy Technology Data Exchange (ETDEWEB)

    Yang, M.J.; /Fermilab

    2007-06-01

    Detailed study of Fermilab Recycler Ring anti-proton injection line became feasible with its BPM system upgrade, though the beamline has been in existence and operational since year 2000. Previous attempts were not fruitful due to limitations in the BPM system. Among the objectives are the assessment of beamline optics and the presence of error fields. In particular the field region of the permanent Lambertson magnets at both ends of R22 transfer line will be scrutinized.

  6. Analysis of effect of late water injection on RCS repressurization

    International Nuclear Information System (INIS)

    Tao Jun; Cao Xuewu

    2011-01-01

    Effect of late water injection on RCS repressurization during high pressure severe accident sequence in a typical PWR was analyzed. As the results shown, late water injection could increase RCS pressure when RPV failed without RCS passive depressurization. Especially in the condition of opening one PORV, RCS pressure could reach high pressure limit when RPV failed and the risk of HPME and DCH was dramatically increased. Integrity of containment could be threatened. However, in the condition of RCS passive depressurization induced by pressurizer surge line creep failure, RCS pressure could be decreased to very low level even only one PORV was opened and two trains of emergency core cooling were implemented. The risk of HPME and DCH was eliminated. The more PORVs were opened, the faster accident progression was and the earlier RPV failed. RCS pressure was a little higher when PRV failed if two trains of emergency core cooling was implemented comparing with the condition with only one train of emergency core cooling. However the time of RPV failure was obviously delayed. From the point of delaying RPV failure and preventing containment early failure of view, the optimized late water injection was opening three PORVs and implementing two trains of emergency core cooling. (authors)

  7. Analysis on complications after intravitreal injection of bevacizumab

    Directory of Open Access Journals (Sweden)

    Cui-Wei Zhang

    2013-08-01

    Full Text Available AIM: To observe and analyze on the incidence rate and causes of complications after anintravitreal injection of bevacizumab. METHODS: Totally, 207 cases(207 eyeswith wet age-related macular degeneration were selected randomly. All cases were treated with intravitreal injections of bevacizumab(1.5mg/0.06mLand asked for chief complaints at 1 day, 1 week, 4, 12 weeks after operation, and also examined for routine visual acuity(best corrected visual acuity, BCVA, non-contact tonometer, slit lamp microscope and indirect ophthalmoscope etc.RESULTS: Among 207 cases(207 eyes, visual acuity improved efficiency was 90.8% 12 weeks after treatment, foreign body sensation was found in 7 cases(3.4%, eyelid skin pruritus in 1 case(0.5%, conjunctival congestion in 6 cases(2.9%, subconjunctival hemorrhage in 1 case(0.5%, post-operative intraocular pressure elevation in 2 cases(1.0%. CONCLUSION: The intravitreal injection of bevacizumab is effective with fewer complications. We propose to carry out a further randomized multicenter and larger-sample clinical research and further draw up the clinical application criterion of bevacizumab.

  8. Sensitive flow-injection spectrophotometric analysis of bromopride

    Science.gov (United States)

    Lima, Liliane Spazzapam; Weinert, Patrícia Los; Pezza, Leonardo; Pezza, Helena Redigolo

    2014-12-01

    A flow injection spectrophotometric procedure employing merging zones is proposed for direct bromopride determination in pharmaceutical formulations and biological fluids. The proposed method is based on the reaction between bromopride and p-dimethylaminocinnamaldehyde (p-DAC) in acid medium, in the presence of sodium dodecyl sulfate (SDS), resulting in formation of a violet product (λmax = 565 nm). Experimental design methodologies were used to optimize the experimental conditions. The Beer-Lambert law was obeyed in a bromopride concentration range of 3.63 × 10-7 to 2.90 × 10-5 mol L-1, with a correlation coefficient (r) of 0.9999. The limits of detection and quantification were 1.07 × 10-7 and 3.57 × 10-7 mol L-1, respectively. The proposed method was successfully applied to the determination of bromopride in pharmaceuticals and human urine, and recoveries of the drug from these media were in the ranges 99.6-101.2% and 98.6-102.1%, respectively. This new flow injection procedure does not require any sample pretreatment steps.

  9. Thermal analysis of the LHC injection kicker magnets

    Science.gov (United States)

    Vega, L.; Abánades, A.; Barnes, M. J.; Vlachodimitropoulos, V.; Weterings, W.

    2017-07-01

    The CERN Large Hadron Collider LHC is equipped with two fast pulsed magnet systems (MKIs) that inject particle beams coming from the injector chain. Operation with high intensity beams for many hours can lead to significant beam induced heating of the ferrite yokes of the MKIs. When the ferrite exceeds the Curie temperature of 125°C it loses its magnetic properties, preventing further injection until the ferrite cools down, potentially causing a delay of several hours. Hence important upgrades of the beam-screen were implemented after Run 1 of LHC. However, the High-Luminosity (HL) LHC will be operated with significantly higher intensity beams and hence additional measures are required to limit the ferrite temperature. These magnets operate under ultra-high vacuum conditions: convection is negligible and, as a result of low emissivity of the inside of the vacuum tanks, thermal radiation is limited. A detailed study of the thermal behaviour of these magnets is reported and compared with measurements. In addition several options to improve cooling of the ferrites are presented and analysed.

  10. Ultrasound- versus palpation-guided injection of corticosteroid for plantar fasciitis: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Zonghuan Li

    Full Text Available It is controversial whether ultrasound-guided injection of corticosteroid is superior to palpation-guided injection for plantar fasciitis. This meta-analysis was performed to compare the effectiveness of ultrasound-guided and palpation-guided injection of corticosteroid for the treatment of plantar fasciitis.Databases (MEDLINE, Cochrane library and EMBASE and reference lists were searched from their establishment to August 30, 2013 for randomized controlled trials (RCTs comparing ultrasound-guided with palpation-guided injection for plantar fasciitis. The Cochrane risk of bias (ROB tool was used to assess the methodological quality. Outcome measurements were visual analogue scale (VAS, tenderness threshold (TT, heel tenderness index (HTI, response rate, plantar fascia thickness (PFT, hypoechogenicity and heel pad thickness (HPT. The statistical analysis was performed with software RevMan 5.2 and Stata 12.0. When I2<50%, the fixed-effects model was adopted. Otherwise the randomized-effects model was adopted. The Grading of Recommendations Assessment, Development and Evaluation (GRADE system was used to assess the quality of evidence.Five RCTs with 149 patients were identified and analyzed. Compared with palpation-guided injection, ultrasound-guided injection was superior with regard to VAS, TT, response rate, PFT and hypoechogenicity. However, there was no statistical significance between the two groups for HPT and HTI.Ultrasound-guided injection of corticosteroid tends to be more effective than palpation-guided injection. However, it needs to be confirmed by further research.

  11. Ultrasound- versus Palpation-Guided Injection of Corticosteroid for Plantar Fasciitis: A Meta-Analysis

    Science.gov (United States)

    Yu, Aixi; Qi, Baiwen

    2014-01-01

    Background It is controversial whether ultrasound-guided injection of corticosteroid is superior to palpation-guided injection for plantar fasciitis. This meta-analysis was performed to compare the effectiveness of ultrasound-guided and palpation-guided injection of corticosteroid for the treatment of plantar fasciitis. Methods Databases (MEDLINE, Cochrane library and EMBASE) and reference lists were searched from their establishment to August 30, 2013 for randomized controlled trials (RCTs) comparing ultrasound-guided with palpation-guided injection for plantar fasciitis. The Cochrane risk of bias (ROB) tool was used to assess the methodological quality. Outcome measurements were visual analogue scale (VAS), tenderness threshold (TT), heel tenderness index (HTI), response rate, plantar fascia thickness (PFT), hypoechogenicity and heel pad thickness (HPT). The statistical analysis was performed with software RevMan 5.2 and Stata 12.0. When I2<50%, the fixed-effects model was adopted. Otherwise the randomized-effects model was adopted. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was used to assess the quality of evidence. Results Five RCTs with 149 patients were identified and analyzed. Compared with palpation-guided injection, ultrasound-guided injection was superior with regard to VAS, TT, response rate, PFT and hypoechogenicity. However, there was no statistical significance between the two groups for HPT and HTI. Conclusion Ultrasound-guided injection of corticosteroid tends to be more effective than palpation-guided injection. However, it needs to be confirmed by further research. PMID:24658102

  12. Principles and Applications of Flow Injection Analysis in Biosensors

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    1996-01-01

    In practical applications biosensors are often forced to operate under less than optimal conditions. Because of their construction, and the physical processes and chemical reactions involved in their operation, compromise conditions are frequently required to synchronize all events taking place....... Therefore, and in order to implement functions such as periodic calibration, conditioning and possible regeneration of the biosensor, and, very importantly, to yield the freedom to select the optimum detection means, it is advantageous to use these devices in a flow-through mode, particularly by employing...... the flow injection (FI) approach. The capacity of FI, as offering itself as a complementary facility to augment the performance of biosensors, and in many cases as an attractive alternative, is demonstrated by reference to selected examples, comprising assays based on enzymatic procedures with optical...

  13. Authentication and distinction of Shenmai injection with HPLC fingerprint analysis assisted by pattern recognition techniques

    Directory of Open Access Journals (Sweden)

    Xue-Feng Lu

    2012-10-01

    Full Text Available In this paper, the feasibility and advantages of employing high performance liquid chromatographic (HPLC fingerprints combined with pattern recognition techniques for quality control of Shenmai injection were investigated and demonstrated. The Similarity Evaluation System was employed to evaluate the similarities of samples of Shenmai injection, and the HPLC generated chromatographic data were analyzed using hierarchical clustering analysis (HCA and soft independent modeling of class analogy (SIMCA. Consistent results were obtained to show that the authentic samples and the blended samples were successfully classified by SIMCA, which could be applied to accurate discrimination and quality control of Shenmai injection. Furthermore, samples could also be grouped in accordance with manufacturers. Our results revealed that the developed method has potential perspective for the original discrimination and quality control of Shenmai injection. Keywords: Shenmai injection, High performance liquid chromatography, Fingerprint, Pattern recognition

  14. Sequential-Injection Analysis: Principles, Instrument Construction, and Demonstration by a Simple Experiment

    Science.gov (United States)

    Economou, A.; Tzanavaras, P. D.; Themelis, D. G.

    2005-01-01

    The sequential-injection analysis (SIA) is an approach to sample handling that enables the automation of manual wet-chemistry procedures in a rapid, precise and efficient manner. The experiments using SIA fits well in the course of Instrumental Chemical Analysis and especially in the section of Automatic Methods of analysis provided by chemistry…

  15. Reverse radiometric flow injection analysis (RFIA) of radioactive waste-waters with an ASIA (Ismatec) analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Win, N; San, K; Han, B; Myoe, K M [Yangon Univ. (Myanmar). Dept. of Chemistry; Toelgyessy, J [Slovak Technical Univ., Bratislava (Slovakia). Dept. of Environmental Science

    1994-07-01

    A new application of reverse radiometric flow injection analysis is described. RFIA was used for the analysis of radioactive wastewaters. ASIA (Ismatec) analyzer with NaI(Tl) scintillation detector was used in the study of analysis of [sup 131]I containing waste-aster. (author) 4 refs.; 3 figs.

  16. Determination of pH by flow-injection analysis and by fiber-optrode analysis

    International Nuclear Information System (INIS)

    Pia, S.H.; Waltman, D.P.; Hillman, D.C.

    1988-07-01

    Two new procedures for measuring pH were developed. The first measures pH colorimetrically using a proprietary indicator-dye mixture in a flow injection analysis (FIA) procedure. The second measures pH using a fiber-optic chemical sensor (FOCS) specifically developed for pH determinations. The FOCS method measures pH by monitoring the fluorescence of a fluorescein derivative bonded to the distal end of a fiber-optic cable called an optrade. The FIA method currently has a precision and accuracy of about + or - 0.2 pH units and can measure 100 samples/hour. The FOCS method has a precision of + or - 0.05-0.20 pH units and an accuracy of + or - 0.1 to 0.6 pH units. About 10 to 60 samples can be analyzed. The characteristics of the FOCS Method will vary significantly with individual optrodes. The experimental results indicate that either flow-injection analysis or fiber optic chemical sensor analysis could form the basis for an alternative to electrometric measurement of pH in certain circumstances

  17. Jet flow analysis of liquid poison injection in a CANDU reactor using source term

    International Nuclear Information System (INIS)

    Chae, Kyung Myung; Choi, Hang Bok; Rhee, Bo Wook

    2001-01-01

    For the performance analysis of Canadian deuterium uranium (CANDU) reactor shutdown system number 2 (SDS2), a computational fluid dynamics model of poison jet flow has been developed to estimate the flow field and poison concentration formed inside the CANDU reactor calandria. As the ratio of calandria shell radius over injection nozzle hole diameter is so large (1055), it is impractical to develop a full-size model encompassing the whole calandria shell. In order to reduce the model to a manageable size, a quarter of one-pitch length segment of the shell was modeled using symmetric nature of the jet; and the injected jet was treated as a source term to avoid the modeling difficulty caused by the big difference of the hole sizes. For the analysis of an actual CANDU-6 SDS2 poison injection, the grid structure was determined based on the results of two-dimensional real- and source-jet simulations. The maximum injection velocity of the liquid poison is 27.8 m/s and the mass fraction of the poison is 8000 ppm (mg/kg). The simulation results have shown well-established jet flow field. In general, the jet develops narrowly at first but stretches rapidly. Then, the flow recirculates a little in r-x plane, while it recirculates largely in r-θ plane. As the time goes on, the adjacent jets contact each other and form a wavy front such that the whole jet develops in a plate form. his study has shown that the source term model can be effectively used for the analysis of the poison injection and the simulation result of the CANDU reactor is consistent with the model currently being used for the safety analysis. In the future, it is strongly recommended to analyze the transient (from helium tank to injection nozzle hole) of the poison injection by applying Bernoulli equation with real boundary conditions

  18. Load Flow Analysis of a 15Mva Injection Substation | Oshevire ...

    African Journals Online (AJOL)

    This load flow helps to determine the state of the power system for a given load and generation distribution. This paper presents the computer aided power flow analysis of the existing Otovwodo33/11kV distribution network using the ETAP 7.0 software. The result showed that out of 91load feeders of which 6 is out of service, ...

  19. On-line monitoring of Glucose and penicillin by sequential injection analysis

    DEFF Research Database (Denmark)

    Min, R.W.; Nielsen, Jens Bredal; Villadsen, John

    1996-01-01

    and a detector. The glucose analyzer is based on an enzymatic reaction using glucose oxidase, which converts glucose to glucono-lactone with formation of hydrogen peroxide and subsequent detection of H2O2 by a chemiluminescence reaction involving luminol. The penicillin analysis is based on formation......A sequential injection analysis (SIA) system has been developed for on-line monitoring of glucose and penicillin during cultivations of the filamentous fungus Penicillium chrysogenum. The SIA system consists of a peristaltic pump, an injection valve, two piston pumps, two multi-position valves...

  20. Comprehensive experimental analysis of nonlinear dynamics in an optically-injected semiconductor laser

    Directory of Open Access Journals (Sweden)

    Kevin Schires

    2011-09-01

    Full Text Available We present the first comprehensive experimental study, to our knowledge, of the routes between nonlinear dynamics induced in a semiconductor laser under external optical injection based on an analysis of time-averaged measurements of the optical and RF spectra and phasors of real-time series of the laser output. The different means of analysis are compared for several types of routes and the benefits of each are discussed in terms of the identification and mapping of the nonlinear dynamics. Finally, the results are presented in a novel audio/video format that describes the evolution of the dynamics with the injection parameters.

  1. Recommended HPI [High Pressure Injection] rates for the TMI-2 analysis exercise (0 to 300 minutes)

    International Nuclear Information System (INIS)

    Anderson, J.L.

    1987-09-01

    An international analysis exercise has been organized to evaluate the ability of nuclear reactor severe accident computer codes to predict the TMI-2 accident sequence and core damage progression during the first 300 minutes of the accident. A required boundary condition for the analysis exercise is the High Pressure Injection or make-up rates into the primary system during the accident. Recommended injection rates for the first 300 minutes of the accident are presented. Recommendations for several sensitivity studies are also presented. 6 refs., 5 figs., 1 tab

  2. Meta-analysis of Huangqi injection for the adjunctive therapy of aplastic anemia

    Science.gov (United States)

    Zhu, Changtai; Gao, Yulu; Jiang, Ting; Hao, Cao; Gao, Zongshuai; Sun, Yongning

    2015-01-01

    Aplastic anemia therapy remains difficult, due to lack of effective treatment regimens. In recent years, Huangqi injection for the adjunctive therapy of aplastic anemia has been reported in many clinical trials. Considering that Huangqi injection may be a novel approach to aplastic anemia treatment, we conducted a meta-analysis of clinical controlled trials to assess the clinical value of Huangqi injection in the treatment of aplastic anemia. We searched the Chinese Biomedical Literature Database (CBM), China National Knowledge Infrastructure (CNKI), Chinese Scientific Journals Full-text Database (VIP), Wanfang Database, PubMed and EMBASE database to collect the data about the trials of Huangqi injection combined with androgens for treating aplastic anemia. A total of ten studies involving 720 patients with aplastic anemia were included in this study. The meta-analysis showed significant increases in the pool effectiveness rate, white blood cells (WBC), haematoglobin (Hb), platelets (PLT), and reticulocytes (Ret) between the experimental group versus the control group. No severe side effects were found in this study. However, the lower Jadad scores and asymmetric funnel plot degrades the validity of the meta-analysis as the clinical evidence. Therefore, Huangqi injection may significantly enhance the efficacy of androgens for aplastic anemia, suggesting that the novel approach of Chinese traditional medicine combined with Western medicine is promising. The exact outcome required confirmation with rigorously well-designed multi-center trials. PMID:26379817

  3. Steam injection for heavy oil recovery: Modeling of wellbore heat efficiency and analysis of steam injection performance

    International Nuclear Information System (INIS)

    Gu, Hao; Cheng, Linsong; Huang, Shijun; Li, Bokai; Shen, Fei; Fang, Wenchao; Hu, Changhao

    2015-01-01

    Highlights: • A comprehensive mathematical model was established to estimate wellbore heat efficiency of steam injection wells. • A simplified approach of predicting steam pressure in wellbores was proposed. • High wellhead injection rate and wellhead steam quality can improve wellbore heat efficiency. • High wellbore heat efficiency does not necessarily mean good performance of heavy oil recovery. • Using excellent insulation materials is a good way to save water and fuels. - Abstract: The aims of this work are to present a comprehensive mathematical model for estimating wellbore heat efficiency and to analyze performance of steam injection for heavy oil recovery. In this paper, we firstly introduce steam injection process briefly. Secondly, a simplified approach of predicting steam pressure in wellbores is presented and a complete expression for steam quality is derived. More importantly, both direct and indirect methods are adopted to determine the wellbore heat efficiency. Then, the mathematical model is solved using an iterative technique. After the model is validated with measured field data, we study the effects of wellhead injection rate and wellhead steam quality on steam injection performance reflected in wellbores. Next, taking cyclic steam stimulation as an example, we analyze steam injection performance reflected in reservoirs with numerical reservoir simulation method. Finally, the significant role of improving wellbore heat efficiency in saving water and fuels is discussed in detail. The results indicate that we can improve the wellbore heat efficiency by enhancing wellhead injection rate or steam quality. However, high wellbore heat efficiency does not necessarily mean satisfactory steam injection performance reflected in reservoirs or good performance of heavy oil recovery. Moreover, the paper shows that using excellent insulation materials is a good way to save water and fuels due to enhancement of wellbore heat efficiency

  4. Effect analysis of intradermal hyaluronic acid injection to treat enlarged facial pores.

    Science.gov (United States)

    Qian, Wei; Zhang, Yan-Kun; Hou, Ying; Lyu, Wei; Cao, Qian; Li, Yan-Qi; Fan, Ju-Feng

    2017-08-08

    To investigate the clinical application and efficacy of intradermal injection of low molecular weight hyaluronic acid (LMW-HA) for treating enlarged facial pores. From January 2015 to May 2016, 42 subjects who sought aesthetic treatment underwent intradermal injection of LMW-HA to improve enlarged facial pores. For each treatment, 2.5 mL (25 mg) of LMW-HA was injected into the skin of the full face. The treatment was repeated 2-5 times with an interval of 1 to 1.5 months between consecutive treatments. The postoperative follow-up period was 1 to 6 months. Statistical analysis was used to compare the degree of enlargement of facial pores before and after injection. The clinical efficacy and adverse effects were recorded. The enlarged facial pores before and after treatment were categorized and subjected to the Wilcoxon matched-pairs signed-rank test. The difference was statistically significant (Pinjection sites in the subjects who sought aesthetic treatment. The overall satisfaction rate was 92.8%. Intradermal injection of LMW-HA can significantly improve skin texture, reduce pore size, and enhance skin radiance. The injection technique was simple, safe, and effective and could easily be extended to clinical practice. © 2017 Wiley Periodicals, Inc.

  5. Whole Genome Analysis of Injectional Anthrax Identifies Two Disease Clusters Spanning More Than 13 Years

    Directory of Open Access Journals (Sweden)

    Paul Keim

    2015-11-01

    Lay Person Interpretation: Injectional anthrax has been plaguing heroin drug users across Europe for more than 10 years. In order to better understand this outbreak, we assessed genomic relationships of all available injectional anthrax strains from four countries spanning a >12 year period. Very few differences were identified using genome-based analysis, but these differentiated the isolates into two distinct clusters. This strongly supports a hypothesis of at least two separate anthrax spore contamination events perhaps during the drug production processes. Identification of two events would not have been possible from standard epidemiological analysis. These comprehensive data will be invaluable for classifying future injectional anthrax isolates and for future geographic attribution.

  6. Cost analysis of injection laryngoplasty performed under local anaesthesia versus general anaesthesia: an Australian perspective.

    Science.gov (United States)

    Chandran, D; Woods, C M; Schar, M; Ma, N; Ooi, E H; Athanasiadis, T

    2018-02-01

    To conduct a cost analysis of injection laryngoplasty performed in the operating theatre under local anaesthesia and general anaesthesia. The retrospective study included patients who had undergone injection laryngoplasty as day cases between July 2013 and March 2016. Cost data were obtained, along with patient demographics, anaesthetic details, type of injectant, American Society of Anesthesiologists score, length of stay, total operating theatre time and surgeon procedure time. A total of 20 cases (general anaesthesia = 6, local anaesthesia = 14) were included in the cost analysis. The mean total cost under general anaesthesia (AU$2865.96 ± 756.29) was significantly higher than that under local anaesthesia (AU$1731.61 ± 290.29) (p costs. Procedures performed under local anaesthesia in the operating theatre are associated with shorter operating theatre time and length of stay in the hospital, and provide significant cost savings. Further savings could be achieved if local anaesthesia procedures were performed in the office setting.

  7. Coupled Viscous Fluid Flow and Joint Deformation Analysis for Grout Injection in a Rock Joint

    Science.gov (United States)

    Kim, Hyung-Mok; Lee, Jong-Won; Yazdani, Mahmoud; Tohidi, Elham; Nejati, Hamid Reza; Park, Eui-Seob

    2018-02-01

    Fluid flow modeling is a major area of interest within the field of rock mechanics. The main objective of this study is to gain insight into the performance of grout injection inside jointed rock masses by numerical modeling of grout flow through a single rock joint. Grout flow has been widely simulated using non-Newtonian Bingham fluid characterized by two main parameters of dynamic viscosity and shear yield strength both of which are time dependent. The increasing value of these properties with injection time will apparently affect the parameters representing the grouting performance including grout penetration length and volumetric injection rate. In addition, through hydromechanical coupling a mutual influence between the injection pressure from the one side and the joint opening/closing behavior and the aperture profile variation on the other side is anticipated. This is capable of producing a considerable impact on grout spread within the rock joints. In this study based on the Bingham fluid model, a series of numerical analysis has been conducted using UDEC to simulate the flow of viscous grout in a single rock joint with smooth parallel surfaces. In these analyses, the time-dependent evolution of the grout fluid properties and the hydromechanical coupling have been considered to investigate their impact on grouting performance. In order to verify the validity of these simulations, the results of analyses including the grout penetration length and the injection flow rate were compared with a well-known analytical solution which is available for the simple case of constant grout properties and non-coupled hydraulic analysis. The comparison demonstrated that the grout penetration length can be overestimated when the time-dependent hardening of grout material is not considered. Moreover, due to the HM coupling, it was shown that the joint opening induced by injection pressure may have a considerable increasing impression on the values of penetration length and

  8. Analysis of Precooling Injection Transient of Steam Generator for High Temperature Gas Cooled Reactor

    Directory of Open Access Journals (Sweden)

    Yan Wang

    2017-01-01

    Full Text Available After a postulated design basis accident leads high temperature gas cooled reactor to emergency shutdown, steam generator still remains with high temperature level and needs to be cooled down by a precooling before reactor restarts with clearing of fault. For the large difference of coolant temperature between inlet and outlet of steam generator in normal operation, the temperature distribution on the components of steam generator is very complicated. Therefore, the temperature descending rate of the components in steam generator needs to be limited to avoid the potential damage during the precooling stage. In this paper, a pebble-bed high temperature gas cooled reactor is modeled by thermal-hydraulic system analysis code and several postulated precooling injection transients are simulated and compared to evaluate their effects, which will provide support for the precooling design. The analysis results show that enough precooling injection is necessary to satisfy the precooling requirements, and larger mass flow rate of precooling water injection will accelerate the precooling process. The temperature decrease of steam generator is related to the precooling injection scenarios, and the maximal mass flow rate of the precooling injection should be limited to avoid the excessively quick temperature change of the structures in steam generator.

  9. Effects of dezocine on prevention of propofol injection pain: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Zhou C

    2017-06-01

    Full Text Available Chengmao Zhou,1,* Yuting Yang,2,* Yu Zhu,3 Lin Ruan4 1Department of Anesthesiology, Zhaoqing Medical College, Zhaoqing, 2Department of Oncology, The First People’s Hospital of Changde, Changde, 3Department of Nursing, Zhaoqing Medical College, Zhaoqing, 4Department of Anesthesiology, Affiliated Tumor Hospital of Guangxi Medical University, Nanning, People’s Republic of China *These authors contributed equally to this work Objective: The objective of this study was to evaluate the effects of dezocine on the prevention of propofol injection pain.Materials and methods: We searched for randomized controlled trials (RCTs of dezocine in preventing propofol injection pain, from inception to April 2016, in PubMed, Embase, Cochrane Library, and CNKI. Next, two reviewers independently screened literature, extracted data, and assessed quality in accordance with the inclusion and exclusion criteria. Finally, RevMan 5.2 software was used to conduct a meta-analysis.Results: Seven RCTs totaling 630 patients were included in this meta-analysis. The meta-analysis study showed: 1 compared with the control group (relative risk [RR] =0.32, 95% CI [0.26, 0.39], P<0.00001, the dezocine group showed a decreasing incidence of propofol injection pain; 2 for severity of propofol injection pain, incidences of mild pain (RR =0.55, 95% CI [0.40, 0.75], P=0.0001, moderate pain (RR =0.28, 95% CI [0.18, 0.43], P<0.00001, and severe pain (RR =0.11, 95% CI [0.06, 0.23], P<0.00001 were considerably lower in the dezocine group than in the control group; 3 when comparing the incidence of propofol injection pain in the dezocine group with that of the lidocaine group, no statistically significant differences were found (RR =0.86, 95% CI [0.66, 1.13], P=0.29; and 4 subgroup analysis indicated a significant reduction in the incidence of propofol injection.Conclusion: Dezocine can both prevent propofol injection pain and mitigate its severity, and its efficacy shows no significant

  10. Analysis of Harmonic Injection to the Modulation of Multi-Level ...

    African Journals Online (AJOL)

    This paper explores the analysis of third and ninth harmonic injection to the modulation of a multilevel diode clamped converter (DCC) at a varying modulation index. The spectral distributions of the various multi-level waveforms obtained under normal modulation index of 0.8 and over modulation index of 1.15 were ...

  11. Wavelet transform for the evaluation of peak intensities in flow-injection analysis

    NARCIS (Netherlands)

    Bos, M.; Hoogendam, E.

    1992-01-01

    The application of the wavelet transform in the determination of peak intensities in flow-injection analysis was studied with regard to its properties of minimizing the effects of noise and baseline drift. The results indicate that for white noise and a favourable peak shape a signal-to-noise ratio

  12. Wavelett transform for the evaluation of peak intensities in flow-injection analysis

    NARCIS (Netherlands)

    Bos, M.; Hoogendam, E.; Hoogendam, E.

    1992-01-01

    The application of the wavelet transform in the determination of peak intensities in flow-injection analysis was studied with regard to its properties of minimizing the effects of noise and baseline drift. The results indicate that for white noise and a favourable peak shape a signal-to-noise ratio

  13. Flow injection analysis using carbon film resistor electrodes for amperometric determination of ambroxol.

    Science.gov (United States)

    Felix, Fabiana S; Brett, Christopher M A; Angnes, Lúcio

    2008-06-30

    Flow injection analysis (FIA) using a carbon film sensor for amperometric detection was explored for ambroxol analysis in pharmaceutical formulations. The specially designed flow cell designed in the lab generated sharp and reproducible current peaks, with a wide linear dynamic range from 5x10(-7) to 3.5x10(-4) mol L(-1), in 0.1 mol L(-1) sulfuric acid electrolyte, as well as high sensitivity, 0.110 Amol(-1) L cm(-2) at the optimized flow rate. A detection limit of 7.6x10(-8) mol L(-1) and a sampling frequency of 50 determinations per hour were achieved, employing injected volumes of 100 microL and a flow rate of 2.0 mL min(-1). The repeatability, expressed as R.S.D. for successive and alternated injections of 6.0x10(-6) and 6.0x10(-5) mol L(-1) ambroxol solutions, was 3.0 and 1.5%, respectively, without any noticeable memory effect between injections. The proposed method was applied to the analysis of ambroxol in pharmaceutical samples and the results obtained were compared with UV spectrophotometric and acid-base titrimetric methods. Good agreement between the results utilizing the three methods and the labeled values was achieved, corroborating the good performance of the proposed electrochemical methodology for ambroxol analysis.

  14. [Reliability theory based on quality risk network analysis for Chinese medicine injection].

    Science.gov (United States)

    Li, Zheng; Kang, Li-Yuan; Fan, Xiao-Hui

    2014-08-01

    A new risk analysis method based upon reliability theory was introduced in this paper for the quality risk management of Chinese medicine injection manufacturing plants. The risk events including both cause and effect ones were derived in the framework as nodes with a Bayesian network analysis approach. It thus transforms the risk analysis results from failure mode and effect analysis (FMEA) into a Bayesian network platform. With its structure and parameters determined, the network can be used to evaluate the system reliability quantitatively with probabilistic analytical appraoches. Using network analysis tools such as GeNie and AgenaRisk, we are able to find the nodes that are most critical to influence the system reliability. The importance of each node to the system can be quantitatively evaluated by calculating the effect of the node on the overall risk, and minimization plan can be determined accordingly to reduce their influences and improve the system reliability. Using the Shengmai injection manufacturing plant of SZYY Ltd as a user case, we analyzed the quality risk with both static FMEA analysis and dynamic Bayesian Network analysis. The potential risk factors for the quality of Shengmai injection manufacturing were identified with the network analysis platform. Quality assurance actions were further defined to reduce the risk and improve the product quality.

  15. Optimization of a flow injection analysis system for multiple solvent extraction

    International Nuclear Information System (INIS)

    Rossi, T.M.; Shelly, D.C.; Warner, I.M.

    1982-01-01

    The performance of a multistage flow injection analysis solvent extraction system has been optimized. The effect of solvent segmentation devices, extraction coils, and phase separators on performance characteristics is discussed. Theoretical consideration is given to the effects and determination of dispersion and the extraction dynamics within both glass and Teflon extraction coils. The optimized system has a sample recovery similar to an identical manual procedure and a 1.5% relative standard deviation between injections. Sample throughput time is under 5 min. These characteristics represent significant improvements over the performance of the same system before optimization. 6 figures, 2 tables

  16. Analysis of Cavity Pressure and Warpage of Polyoxymethylene Thin Walled Injection Molded Parts: Experiments and Simulations

    DEFF Research Database (Denmark)

    Guerrier, Patrick; Tosello, Guido; Hattel, Jesper Henri

    2014-01-01

    Process analysis and simulations on molding experiments of 3D thin shell parts have been conducted. Moldings were carried out with polyoxymethylene (POM). The moldings were performed with cavity pressure sensors in order to compare experimental process results with simulations. The warpage...... was characterized by measuring distances using a tactile coordinate measuring machine (CMM). Molding simulations have been executed taking into account actual processing conditions. Various aspects have been considered in the simulation: machine barrel geometry, injection speed profiles, cavity injection pressure......, melt and mold temperatures, material rheological and pvT characterization. Factors investigated for comparisons were: injection pressure profile, short shots length, flow pattern, and warpage. A reliable molding experimental database was obtained, accurate simulations were conducted and a number...

  17. Recent Development in Optical Chemical Sensors Coupling with Flow Injection Analysis

    Directory of Open Access Journals (Sweden)

    Fuensanta Sánchez Rojas

    2006-10-01

    Full Text Available Optical techniques for chemical analysis are well established and sensors based on thesetechniques are now attracting considerable attention because of their importance in applications suchas environmental monitoring, biomedical sensing, and industrial process control. On the other hand,flow injection analysis (FIA is advisable for the rapid analysis of microliter volume samples and canbe interfaced directly to the chemical process. The FIA has become a widespread automatic analyticalmethod for more reasons; mainly due to the simplicity and low cost of the setups, their versatility, andease of assembling. In this paper, an overview of flow injection determinations by using opticalchemical sensors is provided, and instrumentation, sensor design, and applications are discussed. Thiswork summarizes the most relevant manuscripts from 1980 to date referred to analysis using opticalchemical sensors in FIA.

  18. Modelling injection moulding machines for micro manufacture applications through functional analysis

    DEFF Research Database (Denmark)

    Fantoni, G.; Tosello, Guido; Gabelloni, D.

    2012-01-01

    The paper presents the analysis of an injection moulding machine using functional analysis to identify both its critical components and possible working problems when such a machine is employed for the production of polymer-based micro products. The step-by-step procedure starts from the study...... of the process phases of a machine and then it employs functional analysis to decompose the phases and attributes functions to part features. Part features are subsequently analyzed to understand the causal chains bringing either to the desired behaviour or to failures to avoid. The assessment of the design...... solution is finally performed by gathering quantitative data from experiments. The case study investigates the design motivations and functional drivers of a micro injection moulding machine. The analysis allows identifying the correlations between failures and advantages with the design of the machine...

  19. Injection therapy for chronic prostatitis: A retrospective analysis of 77 cases

    Directory of Open Access Journals (Sweden)

    Attila Toth

    2018-03-01

    Full Text Available Objective: To compare pre- and post-therapy symptom scores reported on the National Institute of Health Chronic Prostatitis Symptom Index (NIHCPSI after trans-rectal antibiotic injections therapy for men suffering from chronic prostatitis. Materials and methods: Retrospective analysis of NIHCPSI symptom scores obtained from chart reviews of 77 treated males suffering from chronic prostatitis before and after trans rectal injections for the treatment of chronic prostatitis. Results: Most patients reported a 40% to 60% improvement in symptom scores. In subgroups comparing scores in patients with less than 5 injections, the improvement was less than in patients who received 10 or more injections. Patients’ responses after a shorter (3 months follow up showed better pain scores than patient’s scores after longer, over one-year or more, follow- up periods. Conclusion: Our findings show that direct antibiotic injection for chronic prostatitis is a viable addition to standard therapies. Improvements in symptom scores are long lasting. Discomfort is minimal and side effects are rare and avoidable

  20. Results and analysis of the TMX electron-beam injection experiments

    International Nuclear Information System (INIS)

    Poulsen, P.; Grubb, D.P.

    1980-01-01

    Electron beams (e-beams) were injected into the Tandem Mirror Experiment (TMX) plasma in order to investigate the effect on the ion cyclotron fluctuations of the plasma. The power level of the e-beams was comparable to that of the injected neutral beams. It was found that injection of the e-beams produced no significant effect on the ion cyclotron fluctuations, the measured plasma parameters, or the particle and power flow of the plasma. The increase in bulk electron temperature and the production of mirror-confined electrons found in previous experiments in which e-beams were injected into a mirror-confined plasma were not observed in this experiment. Analysis of the regions and frequencies of wave creation and absorption within the plasma shows that the plasma density and magnetic field profiles through the plasma strongly affect the resonances encountered by the waves. The steep axial density profiles produced by neutral-beam injection in the TMX experiment are not conducive to efficient coupling of the e-beam energy to the plasma

  1. Development of an automated flow injection analysis system for determination of phosphate in nutrient solutions.

    Science.gov (United States)

    Karadağ, Sevinç; Görüşük, Emine M; Çetinkaya, Ebru; Deveci, Seda; Dönmez, Koray B; Uncuoğlu, Emre; Doğu, Mustafa

    2018-01-25

    A fully automated flow injection analysis (FIA) system was developed for determination of phosphate ion in nutrient solutions. This newly developed FIA system is a portable, rapid and sensitive measuring instrument that allows on-line analysis and monitoring of phosphate ion concentration in nutrient solutions. The molybdenum blue method, which is widely used in FIA phosphate analysis, was adapted to the developed FIA system. The method is based on the formation of ammonium Mo(VI) ion by reaction of ammonium molybdate with the phosphate ion present in the medium. The Mo(VI) ion then reacts with ascorbic acid and is reduced to the spectrometrically measurable Mo(V) ion. New software specific for flow analysis was developed in the LabVIEW development environment to control all the components of the FIA system. The important factors affecting the analytical signal were identified as reagent flow rate, injection volume and post-injection flow path length, and they were optimized using Box-Behnken experimental design and response surface methodology. The optimum point for the maximum analytical signal was calculated as 0.50 mL min -1 reagent flow rate, 100 µL sample injection volume and 60 cm post-injection flow path length. The proposed FIA system had a sampling frequency of 100 samples per hour over a linear working range of 3-100 mg L -1 (R 2  = 0.9995). The relative standard deviation (RSD) was 1.09% and the limit of detection (LOD) was 0.34 mg L -1 . Various nutrient solutions from a tomato-growing hydroponic greenhouse were analyzed with the developed FIA system and the results were found to be in good agreement with vanadomolybdate chemical method findings. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  2. How Flow Injection Analysis (FIA) over the past 25 years has changed our way of performing chemical analyses

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Miró, Manuel

    2007-01-01

    Briefly looking back on the impact of flow injection analysis (FIA), as reflected in the rapid growth of publications in the scientific literature, and touching upon many of the novel and unique analytical chemical possibilities that FIA and its sequels, sequential injection analysis (SIA) and La...

  3. Modeling and flow analysis of pure nylon polymer for injection molding process

    International Nuclear Information System (INIS)

    Nuruzzaman, D M; Kusaseh, N; Basri, S; Hamedon, Z; Oumer, A N

    2016-01-01

    In the production of complex plastic parts, injection molding is one of the most popular industrial processes. This paper addresses the modeling and analysis of the flow process of the nylon (polyamide) polymer for injection molding process. To determine the best molding conditions, a series of simulations are carried out using Autodesk Moldflow Insight software and the processing parameters are adjusted. This mold filling commercial software simulates the cavity filling pattern along with temperature and pressure distributions in the mold cavity. In the modeling, during the plastics flow inside the mold cavity, different flow parameters such as fill time, pressure, temperature, shear rate and warp at different locations in the cavity are analyzed. Overall, this Moldflow is able to perform a relatively sophisticated analysis of the flow process of pure nylon. Thus the prediction of the filling of a mold cavity is very important and it becomes useful before a nylon plastic part to be manufactured. (paper)

  4. Theoretical considerations of Flow Injection Analysis in the Absence of Chemical Reactions

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    2000-01-01

    The fundamental mechanism of flow injection analysis (FIA) is assumed to be simple dissusion and the response of the detector is included in a model description that provide information about the shape of the FIA peak in terms of, basically, five parameters. Two of the five parameters are associa...... that any deviation from the features of the present model and the results of a tentative chemical reaction with one of the test compounds, is related to chemical kinetics.......The fundamental mechanism of flow injection analysis (FIA) is assumed to be simple dissusion and the response of the detector is included in a model description that provide information about the shape of the FIA peak in terms of, basically, five parameters. Two of the five parameters...

  5. Optimized and validated flow-injection spectrophotometric analysis of topiramate, piracetam and levetiracetam in pharmaceutical formulations.

    Science.gov (United States)

    Hadad, Ghada M; Abdel-Salam, Randa A; Emara, Samy

    2011-12-01

    Application of a sensitive and rapid flow injection analysis (FIA) method for determination of topiramate, piracetam, and levetiracetam in pharmaceutical formulations has been investigated. The method is based on the reaction with ortho-phtalaldehyde and 2-mercaptoethanol in a basic buffer and measurement of absorbance at 295 nm under flow conditions. Variables affecting the determination such as sample injection volume, pH, ionic strength, reagent concentrations, flow rate of reagent and other FIA parameters were optimized to produce the most sensitive and reproducible results using a quarter-fraction factorial design, for five factors at two levels. Also, the method has been optimized and fully validated in terms of linearity and range, limit of detection and quantitation, precision, selectivity and accuracy. The method was successfully applied to the analysis of pharmaceutical preparations.

  6. Modeling and flow analysis of pure nylon polymer for injection molding process

    Science.gov (United States)

    Nuruzzaman, D. M.; Kusaseh, N.; Basri, S.; Oumer, A. N.; Hamedon, Z.

    2016-02-01

    In the production of complex plastic parts, injection molding is one of the most popular industrial processes. This paper addresses the modeling and analysis of the flow process of the nylon (polyamide) polymer for injection molding process. To determine the best molding conditions, a series of simulations are carried out using Autodesk Moldflow Insight software and the processing parameters are adjusted. This mold filling commercial software simulates the cavity filling pattern along with temperature and pressure distributions in the mold cavity. In the modeling, during the plastics flow inside the mold cavity, different flow parameters such as fill time, pressure, temperature, shear rate and warp at different locations in the cavity are analyzed. Overall, this Moldflow is able to perform a relatively sophisticated analysis of the flow process of pure nylon. Thus the prediction of the filling of a mold cavity is very important and it becomes useful before a nylon plastic part to be manufactured.

  7. Pressure and pressure derivative analysis for injection tests with variable temperature without type-curve matching

    International Nuclear Information System (INIS)

    Escobar, Freddy Humberto; Martinez, Javier Andres; Montealegre Matilde

    2008-01-01

    The analysis of injection tests under nonisothermic conditions is important for the accurate estimation of the reservoir permeability and the well's skin factor; since previously an isothermical system was assumed without taking into account a moving temperature front which expands with time plus the consequent changes in both viscosity and mobility between the cold and the hot zone of the reservoir which leads to unreliable estimation of the reservoir and well parameters. To construct the solution an analytical approach presented by Boughrara and Peres (2007) was used. That solution was initially introduced for the calculation of the injection pressure in an isothermic system. It was later modified by Boughrara and Reynolds (2007) to consider a system with variable temperature in vertical wells. In this work, the pressure response was obtained by numerical solution of the anisothermical model using the Gauss Quadrature method to solve the integrals, and assuming that both injection and reservoir temperatures were kept constant during the injection process and the water saturation is uniform throughout the reservoir. For interpretation purposes, a technique based upon the unique features of the pressure and pressure derivative curves were used without employing type-curve matching (TDS technique). The formulation was verified by its application to field and synthetic examples. As expected, increasing reservoir temperature causes a decrement in the mobility ratio, then estimation of reservoir permeability is some less accurate from the second radial flow, especially, as the mobility ratio increases

  8. The determination, by flow-injection analysis, of iron, sulphate, silver and cadmium

    International Nuclear Information System (INIS)

    Jones, E.A.

    1983-01-01

    This report describes the spectrophotometric determination by flow-injection analysis including, where necessary, liquid-liquid extraction of iron with 1,10-phenanthroline; of sulphate by its catalytic effect on the methylthymol blue-zirconium reaction; of silver with bromopyrogallol red and 1,10-phenanthroline; and of cadmium with dithizone. Optimum conditions for each system are established, and sensitivities and ranges of determination are given

  9. Analysis and modeling of simulated residual stress of mold injected plastic parts by using robust correlations

    OpenAIRE

    Vargas, Carlos; Sierra, Juan; Posada, Juan; Botero-Cadavid, Juan F.

    2017-01-01

    ABSTRACT The injection molding process is the most widely used processing technique for polymers. The analysis of residual stresses generated during this process is crucial for the part quality assessment. The present study evaluates the residual stresses in a tensile strength specimen using the simulation software Moldex3D for two polymers, polypropylene and polycarbonate. The residual stresses obtained under a simulated design of experiment were modeled using a robust multivariable regressi...

  10. Zinc injection implementation process at EDF: risk analysis, chemical specifications and operating procedures

    International Nuclear Information System (INIS)

    Tigeras, A.; Stutzmann, A.; Bremnes, O.; Claeys, M.; Ranchoux, G.; Segura, J.C.; Errera, J.; Bonne, S.

    2010-01-01

    Zinc's ability to replace cobalt from oxides of primary circuit surfaces has provided the first motivation for implementing the zinc addition in BWRs since the mid-1980s. The beneficial results regarding dose reductions have been demonstrated; therefore, this practice has been extended to PWRs since the 1990s, not only for radiation fields considerations, but also for reducing PWSCC. From the beginning of the 2000s, further reasons to inject zinc associated with the fuel management process have been identified (e; g; power increase, high burn-up, and/or cycle length increase). These evolutions must be accompanied by an adapted chemistry program in order to mitigate the crud deposition on fuel assemblies and the consequent AOA/CIPS or localized clad corrosion risks. The source term reduction (due to the decrease of the general corrosion rate of several materials) and the absence of negative impact on alloy cladding in the presence of zinc in the primary coolant are the main reasons for selecting zinc injection as a reliable option for preventing and/or mitigating the effects of fuel deposits. These three PWR motivations (field radiation, components performance, and fuel reliability) are also the major objectives of CANDU®, WWER, and new reactors (EPR, AP1000), where the zinc injection feasibility analyses are in progress in order to improve the safety of their operating conditions. With the purpose of achieving the optimal results of zinc injection, the process's implantation in a unit must be conducted with an appropriate risk analysis, covering all possible domains affected by this primary coolant chemistry modification : safety, fuel and component performance, radioprotection, waste, environment, human and installation security, human and material resources, staff formation, and documentation. EDF has performed a complete analysis of this enlarged scope, relying upon theoretical and experimental results as well as NPP feedback. This paper describes EDF

  11. LCI Databases Sensitivity Analysis of the Environmental Impact of the Injection Molding Process

    Directory of Open Access Journals (Sweden)

    Ana Elduque

    2015-03-01

    Full Text Available During the last decades, society’s concern for the environment has increased. Specific tools like the Life Cycle Assessment (LCA, and software and databases to apply this method have been developed to calculate the environmental burden of products or processes. Calculating the environmental impact of plastic products is relevant as the global plastics production rose to 288 million tons in 2012. Among the different ways of processing plastics, the injection molding process is one of the most used in the industry worldwide. In this paper, a sensitivity analysis of the environmental impact of the injection molding process has been carried out. In order to perform this study, the EcoInvent database inventory for injection molding, and the data from which this database is created, have been studied. Generally, when an LCA of a product is carried out, databases such as EcoInvent, where materials, processes and transports are characterized providing average values, are used to quantify the environmental impact. This approach can be good enough in some cases but in order to assess a specific production process, like injection molding, a further level of detail is needed. This study shows how the final results of environmental impact differ for injection molding when using the PVC’s, PP’s or PET’s data. This aspect suggests the necessity of studying, in a more precise way, this process, to correctly evaluate its environmental burden. This also allows us to identify priority areas and thereby actions to develop a more sustainable way of manufacturing plastics.

  12. SBAS Analysis of Induced Ground Surface Deformation from Wastewater Injection in East Central Oklahoma, USA

    Directory of Open Access Journals (Sweden)

    Elizabeth Loesch

    2018-02-01

    Full Text Available The state of Oklahoma has experienced a dramatic increase in the amount of measurable seismic activities over the last decade. The needs of a petroleum-driven world have led to increased production utilizing various technologies to reach energy reserves locked in tight formations and stimulate end-of-life wells, creating significant amounts of undesirable wastewater ultimately injected underground for disposal. Using Phased Array L-band Synthetic Aperture Radar (PALSAR data, we performed a differential Synthetic Aperture Radar Interferometry (InSAR technique referred to as the Small BAseline Subset (SBAS-based analysis over east central Oklahoma to identify ground surface deformation with respect to the location of wastewater injection wells for the period of December 2006 to January 2011. Our results show broad spatial correlation between SBAS-derived deformation and the locations of injection wells. We also observed significant uplift over Cushing, Oklahoma, the largest above ground crude oil storage facility in the world, and a key hub of the Keystone Pipeline. This finding has significant implications for the oil and gas industry due to its close proximity to the zones of increased seismicity attributed to wastewater injection. Results southeast of Drumright, Oklahoma represent an excellent example of the potential of InSAR, identifying a fault bordered by an area of subduction to the west and uplift to the east. This differentiated movement along the fault may help explain the lack of any seismic activity in this area, despite the large number of wells and high volume of fluid injected.

  13. Coupled analysis of passive safety injection and containment filtered venting for passive decay heat removal - 15140

    International Nuclear Information System (INIS)

    Kim, S.H.; Ham, J.H.; Jeong, Y.H.; Chang, S.H.

    2015-01-01

    developed based on the simulation results from two analysis codes, MARS and MAAP. The early initiation and high mass flow rate from the passive safety injection system could guarantee the convergent containment pressure. In addition, in the loss of coolant accident with the failures of safety injection systems, the passive safety injection system and the containment filtered venting system can be used as a new accident management method. (authors)

  14. Local corticosteroid versus autologous blood injections in lateral epicondylitis: meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Sirico, Felice; Ricca, Flavia; DI Meglio, Franca; Nurzynska, Daria; Castaldo, Clotilde; Spera, Rocco; Montagnani, Stefania

    2017-06-01

    Lateral epicondylitis is a common painful elbow disorder. Several approaches to treatment have been proposed, with a local injection of corticosteroids being the most frequently used. Recent insights into the pathophysiology encouraged the introduction of autologous blood injections as an alternative treatment method. The aim of this meta-analysis is to summarize quantitatively the evidence regarding the efficacy of corticosteroids and autologous blood injections for treatment of pain in lateral epicondylitis. Studies were considered eligible based on the following inclusion criteria: adult human, diagnosis of lateral epicondylitis, randomized controlled trials comparing corticosteroids versus autologous blood injections, pain assessment. Exclusion criteria were previous surgery for lateral epicondylitis or for other elbow disorders, concurrent treatment with drugs or physiotherapy, diagnosis of musculoskeletal systemic disorder. A systematic search of literature was performed according to the PRISMA statement. Effect size of each included study was calculated and analyzed in a random-effects model. Four studies, enrolling total of 218 patients (139 females and 79 males), were included in quantitative analysis. At 2 weeks, there was a trend towards a reduction of VAS score in the corticosteroid group (WMD=2.12 [95% CI: 4.38 to 0.14], P=0.07). No significant differences were recorded in the medium-term (4-12 weeks; WMD=0.85 [95% CI: -0.44 to 2.15], P=0.19) and long-term (24 weeks; WMD=0.63 [95% CI: -2.40 to 3.66], P=0.68) follow-up. Few high-quality trials compare the efficacy of corticosteroid and autologous blood injections in the control of pain related to lateral epicondylitis. Available data indicate that corticosteroids tend to reduce VAS score in short-term follow-up, although these data are not statistically significant. No differences were recorded in the medium and long term. Contrary to popular opinion among medical professionals, and despite

  15. Multi-Level Simulated Fault Injection for Data Dependent Reliability Analysis of RTL Circuit Descriptions

    Directory of Open Access Journals (Sweden)

    NIMARA, S.

    2016-02-01

    Full Text Available This paper proposes data-dependent reliability evaluation methodology for digital systems described at Register Transfer Level (RTL. It uses a hybrid hierarchical approach, combining the accuracy provided by Gate Level (GL Simulated Fault Injection (SFI and the low simulation overhead required by RTL fault injection. The methodology comprises the following steps: the correct simulation of the RTL system, according to a set of input vectors, hierarchical decomposition of the system into basic RTL blocks, logic synthesis of basic RTL blocks, data-dependent SFI for the GL netlists, and RTL SFI. The proposed methodology has been validated in terms of accuracy on a medium sized circuit – the parallel comparator used in Check Node Unit (CNU of the Low-Density Parity-Check (LDPC decoders. The methodology has been applied for the reliability analysis of a 128-bit Advanced Encryption Standard (AES crypto-core, for which the GL simulation was prohibitive in terms of required computational resources.

  16. Numerical analysis of experiments with gas injection into liquid metal coolant

    International Nuclear Information System (INIS)

    Usov, E V; Lobanov, P D; Pribaturin, N A; Mosunova, N A; Chuhno, V I; Kutlimetov, A E

    2016-01-01

    Presented paper contains results of a numerical analysis of experiments with gas injection in water and liquid metal which have been performed at the Institute of Thermophysics Russian Academy of Science (IT RAS). Obtained experimental data are very important to predict processes that take place in the BREST-type reactor during the hypothetical accident with damage of the steam generator tubes, and may be used as a benchmark to validate thermo-hydraulic codes. Detailed description of models to simulate transport of gas phase in a vertical liquid column is presented in a current paper. Two-fluid model with closing relation for wall friction and interface friction coefficients was used to simulate processes which take place in a liquid during injection of gaseous phase. It has being shown that proposed models allow obtaining a good agreement between experimental data and calculation results. (paper)

  17. Irreversibility analysis of magneto-hydrodynamic nanofluid flow injected through a rotary disk

    Directory of Open Access Journals (Sweden)

    Rashidi Mohammad Mehdi

    2015-01-01

    Full Text Available The non-linear Navier-Stokes equations governed on the nanofluid flow injected through a rotary porous disk in the presence of an external uniform vertical magnetic field can be changed to a system of non-linear partial differential equations by applying similar parameter. In this study, partial differential equations are analytically solved by the modified differential transform method, Pade differential transformation method to obtain self-similar functions of motion and temperature. A very good agreement is observed between the obtained results of Pade differential transformation method and those of previously published ones. Then it has become possible to do a comprehensive parametric analysis on the entropy generation in this case to demonstrate the effects of physical flow parameters such as magnetic interaction parameter, injection parameter, nanoparticle volume fraction, dimensionless temperature difference, rotational Brinkman number and the type of nanofluid on the problem.

  18. Pore network quantification of sandstones under experimental CO2 injection using image analysis

    Science.gov (United States)

    Berrezueta, Edgar; González-Menéndez, Luís; Ordóñez-Casado, Berta; Olaya, Peter

    2015-04-01

    Automated-image identification and quantification of minerals, pores and textures together with petrographic analysis can be applied to improve pore system characterization in sedimentary rocks. Our case study is focused on the application of these techniques to study the evolution of rock pore network subjected to super critical CO2-injection. We have proposed a Digital Image Analysis (DIA) protocol that guarantees measurement reproducibility and reliability. This can be summarized in the following stages: (i) detailed description of mineralogy and texture (before and after CO2-injection) by optical and scanning electron microscopy (SEM) techniques using thin sections; (ii) adjustment and calibration of DIA tools; (iii) data acquisition protocol based on image capture with different polarization conditions (synchronized movement of polarizers); (iv) study and quantification by DIA that allow (a) identification and isolation of pixels that belong to the same category: minerals vs. pores in each sample and (b) measurement of changes in pore network, after the samples have been exposed to new conditions (in our case: SC-CO2-injection). Finally, interpretation of the petrography and the measured data by an automated approach were done. In our applied study, the DIA results highlight the changes observed by SEM and microscopic techniques, which consisted in a porosity increase when CO2 treatment occurs. Other additional changes were minor: variations in the roughness and roundness of pore edges, and pore aspect ratio, shown in the bigger pore population. Additionally, statistic tests of pore parameters measured were applied to verify that the differences observed between samples before and after CO2-injection were significant.

  19. An analysis of respondent-driven sampling with injecting drug users in a high HIV prevalent state of India.

    Science.gov (United States)

    Phukan, Sanjib Kumar; Medhi, Gajendra Kumar; Mahanta, Jagadish; Adhikary, Rajatashuvra; Thongamba, Gay; Paranjape, Ramesh S; Akoijam, Brogen S

    2017-07-03

    Personal networks are significant social spaces to spread of HIV or other blood-borne infections among hard-to-reach population, viz., injecting drug users, female sex workers, etc. Sharing of infected needles or syringes among drug users is one of the major routes of HIV transmission in Manipur, a high HIV prevalence state in India. This study was carried out to describe the network characteristics and recruitment patterns of injecting drug users and to assess the association of personal network with injecting risky behaviors in Manipur. A total of 821 injecting drug users were recruited into the study using respondent-driven sampling (RDS) from Bishnupur and Churachandpur districts of Manipur; data on demographic characteristics, HIV risk behaviors, and network size were collected from them. Transition probability matrices and homophily indices were used to describe the network characteristics, and recruitment patterns of injecting drug users. Univariate and multivariate binary logistic regression models were performed to analyze the association between the personal networks and sharing of needles or syringes. The average network size was similar in both the districts. Recruitment analysis indicates injecting drug users were mostly engaged in mixed age group setting for injecting practice. Ever married and new injectors showed lack of in-group ties. Younger injecting drug users had mainly recruited older injecting drug users from their personal network. In logistic regression analysis, higher personal network was found to be significantly associated with increased likelihood of injecting risky behaviors. Because of mixed personal network of new injectors and higher network density associated with HIV exposure, older injecting drug users may act as a link for HIV transmission or other blood-borne infections to new injectors and also to their sexual partners. The information from this study may be useful to understanding the network pattern of injecting drug users

  20. Sequential capillary electrophoresis analysis using optically gated sample injection and UV/vis detection.

    Science.gov (United States)

    Liu, Xiaoxia; Tian, Miaomiao; Camara, Mohamed Amara; Guo, Liping; Yang, Li

    2015-10-01

    We present sequential CE analysis of amino acids and L-asparaginase-catalyzed enzyme reaction, by combing the on-line derivatization, optically gated (OG) injection and commercial-available UV-Vis detection. Various experimental conditions for sequential OG-UV/vis CE analysis were investigated and optimized by analyzing a standard mixture of amino acids. High reproducibility of the sequential CE analysis was demonstrated with RSD values (n = 20) of 2.23, 2.57, and 0.70% for peak heights, peak areas, and migration times, respectively, and the LOD of 5.0 μM (for asparagine) and 2.0 μM (for aspartic acid) were obtained. With the application of the OG-UV/vis CE analysis, sequential online CE enzyme assay of L-asparaginase-catalyzed enzyme reaction was carried out by automatically and continuously monitoring the substrate consumption and the product formation every 12 s from the beginning to the end of the reaction. The Michaelis constants for the reaction were obtained and were found to be in good agreement with the results of traditional off-line enzyme assays. The study demonstrated the feasibility and reliability of integrating the OG injection with UV/vis detection for sequential online CE analysis, which could be of potential value for online monitoring various chemical reaction and bioprocesses. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Interfacing microfluidic handling with spectroscopic detection for real-life applications via the lab-on-valve platform: A review

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Miró, Manuel

    2008-01-01

    with syringe pump propelling devices as a front end to a plethora of spectroscopic detection schemes including UV-Vis spectroscopy, spectrofluorimetry, chemiluminescence, AAS, AFS and ICP-AES/MS. In contrast to lab-on-a-chip units, the versatile configuration of the micromachined LOV readily facilitates...

  2. A cost-benefit/cost-effectiveness analysis of proposed supervised injection facilities in Ottawa, Canada.

    Science.gov (United States)

    Jozaghi, Ehsan; Reid, Andrew A; Andresen, Martin A; Juneau, Alexandre

    2014-08-04

    Supervised injection facilities (SIFs) are venues where people who inject drugs (PWID) have access to a clean and medically supervised environment in which they can safely inject their own illicit drugs. There is currently only one legal SIF in North America: Insite in Vancouver, British Columbia, Canada. The responses and feedback generated by the evaluations of Insite in Vancouver have been overwhelmingly positive. This study assesses whether the above mentioned facility in the Downtown Eastside of Vancouver needs to be expanded to other locations, more specifically that of Canada's capital city, Ottawa. The current study is aimed at contributing to the existing literature on health policy by conducting cost-benefit and cost-effective analyses for the opening of SIFs in Ottawa, Ontario. In particular, the costs of operating numerous SIFs in Ottawa was compared to the savings incurred; this was done after accounting for the prevention of new HIV and Hepatitis C (HCV) infections. To ensure accuracy, two distinct mathematical models and a sensitivity analysis were employed. The sensitivity analyses conducted with the models reveals the potential for SIFs in Ottawa to be a fiscally responsible harm reduction strategy for the prevention of HCV cases--when considered independently. With a baseline sharing rate of 19%, the cumulative annual cost model supported the establishment of two SIFs and the marginal annual cost model supported the establishment of a single SIF. More often, the prevention of HIV or HCV alone were not sufficient to justify the establishment cost-effectiveness; rather, only when both HIV and HCV are considered does sufficient economic support became apparent. Funded supervised injection facilities in Ottawa appear to be an efficient and effective use of financial resources in the public health domain.

  3. An analysis of direct-injection spark-ignition (DISI) soot morphology

    Science.gov (United States)

    Barone, Teresa L.; Storey, John M. E.; Youngquist, Adam D.; Szybist, James P.

    2012-03-01

    We have characterized particle emissions produced by a 4-cylinder, 2.0 L DISI engine using transmission electron microscopy (TEM) and image analysis. Analyses of soot morphology provide insight to particle formation mechanisms and strategies for prevention. Particle emissions generated by two fueling strategies were investigated, early injection and injection modified for low particle number concentration emissions. A blend of 20% ethanol and 80% emissions certification gasoline was used for the study given the likelihood of increased ethanol content in widely available fuel. In total, about 200 particles and 3000 primary soot spherules were individually measured. For the fuel injection strategy which produced low particle number concentration emissions, we found a prevalence of single solid sub-25 nm particles and fractal-like aggregates. The modal diameter of single solid particles and aggregate primary particles was between 10 and 15 nm. Solid particles as small as 6 nm were present. Although nanoparticle aggregates had fractal-like morphology similar to diesel soot, the average primary particle diameter per aggregate had a much wider range that spanned from 7 to 60 nm. For the early fuel injection strategy, liquid droplets were prevalent, and the modal average primary particle diameter was between 20 and 25 nm. The presence of liquid droplets may have been the result of unburned fuel and/or lubricating oil originating from fuel impingement on the piston or cylinder wall; the larger modal aggregate primary particle diameter suggests greater fuel-rich zones in-cylinder than for the low particle number concentration point. However, both conditions produced aggregates with a wide range of primary particle diameters, which indicates heterogeneous fuel and air mixing.

  4. Results and analysis of the 2008-2009 Insulin Injection Technique Questionnaire survey

    NARCIS (Netherlands)

    De Coninck, Carina; Frid, Anders; Gaspar, Ruth; Hicks, Debbie; Hirsch, Larry; Kreugel, Gillian; Liersch, Jutta; Letondeur, Corinne; Sauvanet, Jean-Pierre; Tubiana, Nadia; Strauss, Kenneth

    Background: The efficacy of injection therapy in diabetes depends on correct injection technique and, to provide patients with guidance in this area, we must understand how they currently inject. Methods: From September 2008 to June 2009, 4352 insulin-injecting Type 1 and Type 2 diabetic patients

  5. Passivity-Based Stability Analysis and Damping Injection for Multiparalleled VSCs with LCL Filters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2017-01-01

    is decomposed into a passive filter output admittance in series with an active admittance which is dependent on the current controller and the time delay. The frequency-domain passivity theory is then applied to the active admittance for system stability analysis. It reveals that the stability region...... of the single-loop grid current control is not only dependent on the time delay, but affected also by the resonance frequency of the converter-side filter inductor and filter capacitor. Further on, the damping injection based on the discrete derivative controller is proposed to enhance the passivity...

  6. Cross-flow analysis of injection wells in a multilayered reservoir

    Directory of Open Access Journals (Sweden)

    Mohammadreza Jalali

    2016-09-01

    Natural and forced cross-flow is modeled for some injection wells in an oil reservoir located at North Sea. The solution uses a transient implicit finite difference approach for multiple sand layers with different permeabilities separated by impermeable shale layers. Natural and forced cross-flow rates for each reservoir layer during shut-in are calculated and compared with different production logging tool (PLT measurements. It appears that forced cross-flow is usually more prolonged and subject to a higher flow rate when compared with natural cross-flow, and is thus worthy of more detailed analysis.

  7. Reservoir characterization based on tracer response and rank analysis of production and injection rates

    Energy Technology Data Exchange (ETDEWEB)

    Refunjol, B.T. [Lagoven, S.A., Pdvsa (Venezuela); Lake, L.W. [Univ. of Texas, Austin, TX (United States)

    1997-08-01

    Quantification of the spatial distribution of properties is important for many reservoir-engineering applications. But, before applying any reservoir-characterization technique, the type of problem to be tackled and the information available should be analyzed. This is important because difficulties arise in reservoirs where production records are the only information for analysis. This paper presents the results of a practical technique to determine preferential flow trends in a reservoir. The technique is a combination of reservoir geology, tracer data, and Spearman rank correlation coefficient analysis. The Spearman analysis, in particular, will prove to be important because it appears to be insightful and uses injection/production data that are prevalent in circumstances where other data are nonexistent. The technique is applied to the North Buck Draw field, Campbell County, Wyoming. This work provides guidelines to assess information about reservoir continuity in interwell regions from widely available measurements of production and injection rates at existing wells. The information gained from the application of this technique can contribute to both the daily reservoir management and the future design, control, and interpretation of subsequent projects in the reservoir, without the need for additional data.

  8. Determination of drugs in biological fluids by direct injection of samples for liquid-chromatographic analysis.

    Science.gov (United States)

    Mullett, Wayne M

    2007-03-10

    The analysis of drugs in various biological fluids is an important criterion for the determination of the physiological performance of a drug. After sampling of the biological fluid, the next step in the analytical process is sample preparation. The complexity of biological fluids adds to the challenge of direct determination of the drug by chromatographic analysis, therefore demanding a sample preparation step that is often time-consuming, tedious, and frequently overlooked. However, direct on-line injection methods offer the advantage of reducing sample preparation steps and enabling effective pre-concentration and clean-up of biological fluids. These procedures can be automated and therefore reduce the requirements for handling potentially infectious biomaterial, improve reproducibility, and minimize sample manipulations and potential contamination. The objective of this review is to present an overview of the existing literature with emphasis on advances in automated sample preparation methods for liquid-chromatographic methods. More specifically, this review concentrates on the use of direct injection techniques, such as restricted-access materials, turbulent-flow chromatography and other automated on-line solid-phase extraction (SPE) procedures. It also includes short overviews of emerging automated extraction-phase technologies, such as molecularly imprinted polymers, in-tube solid-phase micro-extraction, and micro-extraction in a packed syringe for a more selective extraction of analytes from complex samples, providing further improvements in the analysis of biological materials. Lastly, the outlook for these methods and potential new applications for these technologies are briefly discussed.

  9. INJECTION MOLDING AND STRUCTURAL ANALYSIS IN METAL TO PLASTIC CONVERSION OF BOLTED FLANGE JOINT BY CAE

    Directory of Open Access Journals (Sweden)

    Marian Blaško

    2014-12-01

    Full Text Available Many metal parts in various applications are being replaced by plastic parts. There are several reasons for that depending on actual application - minimize part cost, enhance corrosion resistance, integrating more components into one part etc. Most important steps of metal to plastic conversion are material selection and design of plastic part. Plastic part has to withstand the same load as metal part. To fulfill this requirement fiber reinforced engineering plastics are often used. Also it is convenient to substitute heavy wall sections with ribbed structure to increase load-carrying ability of part and decrease cycle time, eliminate voids, sink marks etc. Mechanical properties of such part could be highly affected by fiber orientation. Results of fiber orientation from injection molding filling analysis can be used in stress analysis for better prediction of part response to mechanical load. Such coupled analysis is performed here in this case study on bolted flange joint.

  10. Filterless preconcentration, flow injection analysis and detection by inductively-coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    The influence of interferences in the analysis of elements by inductively-coupled-plasma mass-spectrometry (ICP-MS) may be significantly diminished by utilising a protocol of flow-injection analysis (FIA). The method is based on filterless preconcentration of metallic elements at the walls...... of a knotted reactor that was made of nylon tubings. In the load mode, the preconcentration was accomplished by precipitation of metallic species in alkaline-buffered carriers onto the inner walls of the hydrofilic tube. After a preconcen-tration period of 40-120 seconds using sample volumes of 4-10 m...... of 10-30 were obtained in the analysis of aluminium, of chromium and of iron, which resulted in detection limits (3) down to 20 g/L at a sampling frequency of 50 per hour. The preconcentration protocol improves the selectivity thus allowing direct determination of the elements in saline media. Anionic...

  11. Relevant climate response tests for stratospheric aerosol injection: A combined ethical and scientific analysis

    Science.gov (United States)

    Lenferna, Georges Alexandre; Russotto, Rick D.; Tan, Amanda; Gardiner, Stephen M.; Ackerman, Thomas P.

    2017-06-01

    In this paper, we focus on stratospheric sulfate injection as a geoengineering scheme, and provide a combined scientific and ethical analysis of climate response tests, which are a subset of outdoor tests that would seek to impose detectable and attributable changes to climate variables on global or regional scales. We assess the current state of scientific understanding on the plausibility and scalability of climate response tests. Then, we delineate a minimal baseline against which to consider whether certain climate response tests would be relevant for a deployment scenario. Our analysis shows that some climate response tests, such as those attempting to detect changes in regional climate impacts, may not be deployable in time periods relevant to realistic geoengineering scenarios. This might pose significant challenges for justifying stratospheric sulfate aerosol injection deployment overall. We then survey some of the major ethical challenges that proposed climate response tests face. We consider what levels of confidence would be required to ethically justify approving a proposed test; whether the consequences of tests are subject to similar questions of justice, compensation, and informed consent as full-scale deployment; and whether questions of intent and hubris are morally relevant for climate response tests. We suggest further research into laboratory-based work and modeling may help to narrow the scientific uncertainties related to climate response tests, and help inform future ethical debate. However, even if such work is pursued, the ethical issues raised by proposed climate response tests are significant and manifold.

  12. Knee Viscosupplementation: Cost-Effectiveness Analysis between Stabilized Hyaluronic Acid in a Single Injection versus Five Injections of Standard Hyaluronic Acid

    Directory of Open Access Journals (Sweden)

    Francisco J. Estades-Rubio

    2017-03-01

    Full Text Available Given the wide difference in price per vial between various presentations of hyaluronic acid, this study seeks to compare the effectiveness and treatment cost of stabilized hyaluronic acid (NASHA in a single injection with standard preparations of hyaluronic acid (HA in five injections in osteoarthritis (OA of the knee. Fifty-four patients with knee osteoarthritis (Kellgren–Lawrence Grade II and III and the Western Ontario and McMaster Universities Arthritis Index (WOMAC pain score greater than 7, with a homogeneous distribution of age, sex, BMI, and duration of disease, were included in this study. Patients were randomized into two groups: Group I was treated with NASHA (Durolane® and Group II with HA (Go-ON®. Patient’s evolution was followed up at the 1st, 2nd, 4th, 8th, 12th, and 26th week after treatment. A statistically significant improvement in WOMAC score was observed for patients treated with NASHA versus those who received HA at Week 26. In addition, the need for analgesia was significantly reduced at Week 26 in the NASHA-treated group. Finally, the economic analysis showed an increased cost of overall treatment with HA injections. Our data support the use of the NASHA class of products in the treatment of knee OA.

  13. Knee Viscosupplementation: Cost-Effectiveness Analysis between Stabilized Hyaluronic Acid in a Single Injection versus Five Injections of Standard Hyaluronic Acid.

    Science.gov (United States)

    Estades-Rubio, Francisco J; Reyes-Martín, Alvaro; Morales-Marcos, Victor; García-Piriz, Mercedes; García-Vera, Juan J; Perán, Macarena; Marchal, Juan A; Montañez-Heredia, Elvira

    2017-03-17

    Given the wide difference in price per vial between various presentations of hyaluronic acid, this study seeks to compare the effectiveness and treatment cost of stabilized hyaluronic acid (NASHA) in a single injection with standard preparations of hyaluronic acid (HA) in five injections in osteoarthritis (OA) of the knee. Fifty-four patients with knee osteoarthritis (Kellgren-Lawrence Grade II and III) and the Western Ontario and McMaster Universities Arthritis Index (WOMAC) pain score greater than 7, with a homogeneous distribution of age, sex, BMI, and duration of disease, were included in this study. Patients were randomized into two groups: Group I was treated with NASHA (Durolane ® ) and Group II with HA (Go-ON ® ). Patient's evolution was followed up at the 1st, 2nd, 4th, 8th, 12th, and 26th week after treatment. A statistically significant improvement in WOMAC score was observed for patients treated with NASHA versus those who received HA at Week 26. In addition, the need for analgesia was significantly reduced at Week 26 in the NASHA-treated group. Finally, the economic analysis showed an increased cost of overall treatment with HA injections. Our data support the use of the NASHA class of products in the treatment of knee OA.

  14. Performance Analysis of AP1000 Passive Systems during Direct Vessel Injection (DVI Line Break

    Directory of Open Access Journals (Sweden)

    A.S. Ekariansyah

    2016-08-01

    Full Text Available Generation II Nuclear Power Plants (NPPs have a design weakness as shown by the Fukushima accident. Therefore, Generation III+ NPPs are developed with focus on improvements of fuel technology and thermal efficiency, standardized design, and the use of passive safety system. One type of Generation III+ NPP is the AP1000 that is a pressurized water reactor (PWR type that has received the final design acceptance from US-NRC and is already under construction at several sites in China as of 2015. The aim of this study is to investigate the behavior and performance of the passive safety system in the AP1000 and to verify the safety margin during the direct vessel injection (DVI line break as selected event. This event was simulated using RELAP5/SCDAP/Mod3.4 as a best-estimate code developed for transient simulation of light water reactors during postulated accidents. This event is also described in the AP1000 design control document as one of several postulated accidents simulated using the NOTRUMP code. The results obtained from RELAP5 calculation was then compared with the results of simulations using the NOTRUMP code. The results show relatively good agreements in terms of time sequences and characteristics of some injected flow from the passive safety system. The simulation results show that the break of one of the two available DVI lines can be mitigated by the injected coolant flowing, which is operated effectively by gravity and density difference in the cooling system and does not lead to core uncovery. Despite the substantial effort to obtain an apropriate AP1000 model due to lack of detailed geometrical data, the present model can be used as a platform model for other initiating event considered in the AP1000 accident analysis.

  15. Linear stability analysis of the gas injection augmented natural circulation of STAR-LM

    International Nuclear Information System (INIS)

    Yeon-Jong Yoo; Qiao Wu; James J Sienicki

    2005-01-01

    Full text of publication follows: A linear stability analysis has been performed for the gas injection augmented natural circulation of the Secure Transportable Autonomous Reactor - Liquid Metal (STAR-LM). Natural circulation is of great interest for the development of Generation-IV nuclear energy systems due to its vital role in the area of passive safety and reliability. One of such systems is STAR-LM under development by Argonne National Laboratory. STAR-LM is a 400 MWt class modular, proliferation-resistant, and passively safe liquid metal-cooled fast reactor system that uses inert lead (Pb) coolant and the advanced power conversion system that consists of a gas turbine Brayton cycle utilizing supercritical carbon dioxide (CO 2 ) to obtain higher plant efficiency. The primary loop of STAR-LM relies only on the natural circulation to eliminate the use of circulation pumps for passive safety consideration. To enhance the natural circulation of the primary coolant, STAR-LM optionally incorporates the additional driving force provided by the injection of noncondensable gas into the primary coolant above the reactor core, which is effective in removing heat from the core and transferring it to the secondary working fluid without the attainment of excessive coolant temperature at nominal operating power. Therefore, it naturally raises the concern about the natural circulation instability due to the relatively high temperature change in the core and the two-phase flow condition in the hot leg above the core. For the ease of analysis, the flow path of the loop was partitioned into five thermal-hydraulically distinct sections, i.e., heated core, unheated core, hot leg, heat exchanger, and cold leg. The one-dimensional single-phase flow field equations governing the natural circulation, i.e., continuity, momentum, and energy equations, were used for each section except the hot leg. For the hot leg, the one-dimensional homogeneous equilibrium two-phase flow field

  16. Three-Year Analysis of Value and Utilization After Development of an Ultrasound-Based Orthopedic Injection Clinic.

    Science.gov (United States)

    Dukes, Chase; Melton, Thomas; Turner, Eric; Jackson, Andrew; Grassbaugh, Jason; Slevin, John; Arrington, Edward D; Eichinger, Josef K

    2017-09-01

    Sonography is an effective method of diagnosing and treating musculoskeletal conditions, and the use of ultrasound has been shown to improve the accuracy, safety, and efficacy of both therapeutic and diagnostic injections. In 2012, we established an injection clinic at our institution to address our growing need for diagnostic and therapeutic injections. We performed an analysis of value and utilization following the development of an orthopedic injection clinic. This included an evaluation of the cost of materials, equipment, and training required to develop and run the clinic, and an analysis of the services rendered and relative value units (RVUs) generated over 3 fiscal years (FYs). The cost to develop the clinic was $42,498.30. The cost to run the clinic thereafter was $16.90 to $21.60 per injection. By the end of FY 2012, 60% of providers performed at least 1 injection under ultrasound guidance. Every successive year thereafter, 100% of providers were using ultrasound guidance. In FY 2012, we performed 738 injections, 5.4% used ultrasound guidance and generated a total of 1,786.36 RVUs. In FY 2013, we performed 1,814 injections, 17.6% used ultrasound guidance, and generated a total of 7,224.5 RVUs. In FY 2014, we performed 2,821 injections, 25.2% used ultrasound guidance, and generated 13,786.82 RVUs. RVUs generated solely from ultrasound guided injections were 463.2 (2012), 3,694 (2013), 8,221.8 (2014). Injection accuracy was at least 98%. Average time until injection was 0 days. The cost to start an injection clinic is modest, with the potential for large annual growth and early return on investment, and can generate significant revenue by recapturing RVUs that would otherwise be lost to outside referrals. Furthermore, it helps to increase clinic throughput, maximize services rendered during a single patient visit improving the overall quality of their encounter, expands the clinical practice of our midlevel providers, offloads clinical time for surgical

  17. Characterization and analysis of sub-micron surface roughness of injection moulded microfluidic systems using White Light Interferometry

    DEFF Research Database (Denmark)

    Tosello, Guido; Marinello, Francesco; Hansen, Hans Nørgaard

    2009-01-01

    Surface topography is of great importance in polymer micro fluidics, therefore the replication capability of the process and the surface quality of the tool has to be suitably optimized. In this paper, optical profilometry (white light interferometry, WLI) is implemented for topographical...... characterization of polymer surfaces. In particular the study considers replication performance of injection moulding applied for the realization of microfluidic systems for blood analysis. Parts were produced by means of a series of statistically designed injection moulding experiments. Three process parameters...

  18. Public reporting influences antibiotic and injection prescription in primary care: a segmented regression analysis.

    Science.gov (United States)

    Liu, Chenxi; Zhang, Xinping; Wan, Jie

    2015-08-01

    Inappropriate use and overuse of antibiotics and injections are serious threats to the global population, particularly in developing countries. In recent decades, public reporting of health care performance (PRHCP) has been an instrument to improve the quality of care. However, existing evidence shows a mixed effect of PRHCP. This study evaluated the effect of PRHCP on physicians' prescribing practices in a sample of primary care institutions in China. Segmented regression analysis was used to produce convincing evidence for health policy and reform. The PRHCP intervention was implemented in Qian City that started on 1 October 2013. Performance data on prescription statistics were disclosed to patients and health workers monthly in 10 primary care institutions. A total of 326 655 valid outpatient prescriptions were collected. Monthly effective prescriptions were calculated as analytical units in the research (1st to 31st every month). This study involved multiple assessments of outcomes 13 months before and 11 months after PRHCP intervention (a total of 24 data points). Segmented regression models showed downward trends from baseline on antibiotics (coefficient = -0.64, P = 0.004), combined use of antibiotics (coefficient = -0.41, P < 0.001) and injections (coefficient = -0.5957, P = 0.001) after PRHCP intervention. The average expenditure of patients slightly increased monthly before the intervention (coefficient = 0.8643, P < 0.001); PRHCP intervention also led to a temporary increase in average expenditure of patients (coefficient = 2.20, P = 0.307) but slowed down the ascending trend (coefficient = -0.45, P = 0.033). The prescription rate of antibiotics and injections after intervention (about 50%) remained high. PRHCP showed positive effects on physicians' prescribing behaviour, considering the downward trends on the use of antibiotics and injections and average expenditure through the intervention. However, the effect

  19. Large-volume injection in gas chromatographic trace analysis using temperature-programmable (PTV) injectors

    NARCIS (Netherlands)

    Mol, J.G.J.; Janssen, J.G.M.; Cramers, C.A.M.G.; Brinkman, U.A.T.

    1996-01-01

    The use of programmed-temperature vaporising (PTV) injectors for large-volume injection in capillary gas chromatography is briefly reviewed. The principles and optimisation of large-volume PTV injection are discussed. Guidelines are given for selection of the PTV conditions and injection mode for

  20. Polyion selective polymeric membrane-based pulstrode as a detector in flow-injection analysis.

    Science.gov (United States)

    Bell-Vlasov, Andrea K; Zajda, Joanna; Eldourghamy, Ayman; Malinowska, Elzbieta; Meyerhoff, Mark E

    2014-04-15

    A method for the detection of polyions using fully reversible polyion selective polymeric membrane type pulstrodes as detectors in a flow-injection analysis (FIA) system is examined. The detection electrode consists of a plasticized polymeric membrane doped with 10 wt % of tridodecylmethylammonium-dinonylnaphthalene sulfonate (TDMA/DNNS) ion-exchanger salt. The pulse sequence used involves a short (1 s) galvanostatic pulse, an open-circuit pulse (0.5 s) during which the EMF of the cell is measured, and a longer (15 s) potentiostatic pulse to return the membrane to its original chemical composition. It is shown that total pulse sequence times can be optimized to yield reproducible real-time detection of injected samples of protamine and heparin at up to 20 samples/h. Further, it is shown that the same membrane detector can be employed for FIA detection of both polycations at levels ≥10 μg/mL and polyanions at levels of ≥40 μg/mL by changing the direction of the galvanostatic pulse. The methodology described may also be applicable in the detection of polyionic species at low levels in other flowing configurations, such as in liquid chromatography and capillary electrophoresis.

  1. 3-D steady state thermomechanical analysis of a piston of a direct injection diesel engine

    International Nuclear Information System (INIS)

    Abid, M.; Bannikov, M.G.; Ali, H.

    2005-01-01

    Piston of internal combustion engine is subjected to the coupled action of the thermal and the mechanical loads. Piston distortion due to temperature nonuniformities has a significant impact on the piston component of the engine friction. In regions of high heat flux, thermal stresses can reach levels that would cause fatigue cracking. Any change of engine design and/or operating conditions resulting in an increased heat flux through the piston may cause engine performance deterioration and even engine failure. This work presents a three-dimensional finite element analysis of a piston of a high power direct injection diesel engine. The goal of such analysis was the prediction of the piston behavior in conditions of the increased brake mean effective pressure and engine speed. Thermal and mechanical loads required for analysis were obtained from the engine cycle simulation. Thermal boundary conditions were determined in the form of the cycle averaged temperature of combustion chamber content and cycle averaged spatially distributed heat transfer coefficients. Mechanical load was represented by the combined gas pressure and inertia forces. Using ANSYS software temperature and stress distributions within the piston body as well as piston deformation were obtained. Analysis was performed for separate as well as combined load. It was shown that contribution of mechanical load is insignificant and can be neglected. Main emphasis is given to scuffing and strength analysis of the piston. Results obtained at various thermal loads are discussed. (author)

  2. Sexual and injection-related risks in Puerto Rican-born injection drug users living in New York City: A mixed-methods analysis

    Directory of Open Access Journals (Sweden)

    Gelpí-Acosta Camila

    2011-10-01

    Full Text Available Abstract Background These data were collected as part of the National HIV Behavioral Surveillance (NHBS study. NHBS is a cross-sectional study to investigate HIV behavioral risks among core risk groups in 21 U.S. cities with the highest HIV/AIDS prevalence. This analysis examines data from the NHBS data collection cycle with IDU conducted in New York City in 2009. We explored how the recency of migration from Puerto Rico (PR to New York City (NYC impacts both syringe sharing and unprotected sex among injection drug users (IDU currently living in NYC. Methods We used a mixed-methods approach to examine differences in risk between US-born IDU, PR IDU who migrated to NYC more than three years ago (non-recent migrants, and PR IDU who migrated in the last three years (recent migrants. Respondent-driven sampling (RDS was used to recruit the sample (n = 514. In addition, qualitative individual and group interviews with recent PR migrants (n = 12 and community experts (n = 2 allowed for an in-depth exploration of the IDU migration process and the material and cultural factors behind continued risk behaviors in NYC. Results In multiple logistic regression controlling for confounding factors, recent migrants were significantly more likely to report unprotected sexual intercourse with casual or exchange partners (adjusted odds ratio [AOR]: 2.81; 95% confidence intervals [CI]: 1.37-5.76 and receptive syringe sharing (AOR = 2.44; 95% CI: 1.20-4.97 in the past year, compared to US-born IDU. HIV and HCV seroprevalence were highest among non-recent migrants. Qualitative results showed that risky injection practices are partly based on cultural norms acquired while injecting drugs in Puerto Rico. These same results also illustrate how homelessness influences risky sexual practices. Conclusions Poor material conditions (especially homelessness may be key in triggering risky sexual practices. Cultural norms (ingrained while using drugs in PR around injection drug

  3. Influence of injector technology on injection and combustion development - Part 2: Combustion analysis

    Energy Technology Data Exchange (ETDEWEB)

    Payri, R.; Salvador, F.J.; Gimeno, J.; Morena, J. de la [CMT-Motores Termicos, Universidad Politecnica de Valencia, Camino de Vera s/n, E-46022 (Spain)

    2011-04-15

    The influence of injection technology on the fuel-air mixing process and the combustion development are analyzed by means of visualization techniques. For this purpose, two injectors (one solenoid and one piezoelectric) are characterized using an optical accessible two stroke engine. Visualization of liquid penetration has allowed the measurement of the stabilized liquid length, which is related with the efficiency of fuel-air mixing process. A theoretical derivation is used in order to relate this liquid length with chamber conditions, as well as to make a temporal analysis of these phenomena. After this, natural flame emission and chemiluminescence techniques are carried out. These results indicate that the piezoelectric system has a more efficient fuel-air mixing and combustion, reducing the characteristic times as well as soot formation. Finally, a correlation for the ignition delay of the two systems is obtained. (author)

  4. COMBUSTION ANALYSIS OF ALGAL OIL METHYL ESTER IN A DIRECT INJECTION COMPRESSION IGNITION ENGINE

    Directory of Open Access Journals (Sweden)

    HARIRAM V.

    2013-02-01

    Full Text Available Algal oil methyl ester was derived from microalgae (Spirulina sp. The microalga was cultivated in BG 11 media composition in a photobioreactor. Upon harvesting, the biomass was filtered and dried. The algal oil was obtained by a two step solvent extraction method using hexane and ether solvent. Cyclohexane was added to biomass to expel the remaining algal oil. By this method 92% of algal oil is obtained. Transesterification process was carried out to produce AOME by adding sodium hydroxide and methanol. The AOME was blended with straight diesel in 5%, 10% and 15% blend ratio. Combustion parameters were analyzed on a Kirloskar single cylinder direct injection compression ignition engine. The cylinder pressure characteristics, the rate of pressure rise, heat release analysis, performance and emissions were studied for straight diesel and the blends of AOME’s. AOME 15% blend exhibits significant variation in cylinder pressure and rate of heat release.

  5. Bienzymatic Biosensor for Rapid Detection of Aspartame by Flow Injection Analysis

    Directory of Open Access Journals (Sweden)

    Maria-Cristina Radulescu

    2014-01-01

    Full Text Available A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX, carboxyl esterase (CaE and bovine serum albumin (BSA were immobilised with glutaraldehyde (GA onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC. The biosensor response was fast. The sample throughput using a flow injection analysis (FIA system was 40 h−1 with an RSD of 2.7%. The detection limits for both batch and FIA measurements were 0.1 µM for methanol and 0.2 µM for aspartame, respectively. The enzymatic biosensor was successfully applied for aspartame determination in different sample matrices/commercial products (liquid and solid samples without any pre-treatment step prior to measurement.

  6. Midfacial analysis and planning for midface augmentation with injectable filling materials: an anatomical approach.

    Science.gov (United States)

    Taheri, A; Mansoori, P

    2012-06-01

      Midfacial augmentation improves the appearance of patients with flat or ptotic cheek.   To develop a simple method of preoperative delineating the location of the ideal malar prominence and determining the best area to augment with injectable filling materials.   We used detailed analysis of the facial features of some Caucasian men and women as the basis for this study.   We described a technique to locate the ideal malar prominence and proposed a classification of midfacial contour defects.   This method greatly simplifies the surgeon's task of determining the area to be augmented. © 2011 The Authors. Journal of the European Academy of Dermatology and Venereology © 2011 European Academy of Dermatology and Venereology.

  7. An analysis on water hammer in liquid injection shutdown system of CANDU-9

    International Nuclear Information System (INIS)

    Kim, T. H.; Heo, J.; Han, S. K.; Choi, H. Y.; No, T. S.

    2000-01-01

    The water hammer analysis code, PTRAN, is used for computation of transient pressures and pressure differentials in the Liquid Injection Shutdown System(LISS) piping network of CANDU-9 to ensure that the design allowables for LEVEL C Service Limit are met for the water hammer loads resulting from the water hammer. The LISS piping network of CANDU-9 has incorporated design improvement in considering the water hammer, such as declining the horizontal part of helium header, and raising the elevation of the overall system piping configuration, etc. The maximum pressure in the LISS piping network is found to be 7.92 MPa(a) at the closed valve in the vent line, which is below the allowable working pressure and the valve design pressure under Level C service conditions. And it is also shown that the maximum pressure in CANDU-9 is much lower than that in CANDU-6

  8. Reliability analysis of the recirculation phase of the safety injection system of Angra-1

    International Nuclear Information System (INIS)

    Rivera, R.R.J.M.

    1981-09-01

    The calculation of several reliability parameters-failure probability, unavailability and unreliability - of the recirculation phase of the safety injection system of Angra-1, was done. This system has two distinct modes of operation (short term and long term) which were fault tree analysed both separately and as a whole. To obtain quantitative results the computer codes SAMPLE and PRET-KITT were utilized. The former was used to consider the uncertainties in the failure data (drawn integrally from WASH-1400) and the latter to obtain time dependent unreliability values. Hardware failures and common-mode failures were considered. Altough the analysis methods employed here differ somewhat from those used in WASH-1400, the results which could be compared were found to have the order of magnitude. A viability study of some suggestions of system's modifications was performed, and it has shown that some significant reliability improvements can be achieved with reasonably simple changes. (Author) [pt

  9. Analysis of Active Components in Salvia Miltiorrhiza Injection Based on Vascular Endothelial Cell Protection

    Directory of Open Access Journals (Sweden)

    Shen Jie

    2014-09-01

    Full Text Available Correlation analysis based on chromatograms and pharmacological activities is essential for understanding the effective components in complex herbal medicines. In this report, HPLC and measurement of antioxidant properties were used to describe the active ingredients of Salvia miltiorrhiza injection (SMI. HPLC results showed that tanshinol, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, protocatechuic acid and their metabolites in rat serum may contribute to the efficacy of SMI. Assessment of antioxidant properties indicated that differences in the composition of serum powder of SMI caused differences in vascular endothelial cell protection. When bivariate correlation was carried out it was found that salvianolic acid B, tanshinol and protocatechuic aldehyde were active components of SMI because they were correlated to antioxidant properties.

  10. Flow injection analysis simulations and diffusion coefficient determination by stochastic and deterministic optimization methods.

    Science.gov (United States)

    Kucza, Witold

    2013-07-25

    Stochastic and deterministic simulations of dispersion in cylindrical channels on the Poiseuille flow have been presented. The random walk (stochastic) and the uniform dispersion (deterministic) models have been used for computations of flow injection analysis responses. These methods coupled with the genetic algorithm and the Levenberg-Marquardt optimization methods, respectively, have been applied for determination of diffusion coefficients. The diffusion coefficients of fluorescein sodium, potassium hexacyanoferrate and potassium dichromate have been determined by means of the presented methods and FIA responses that are available in literature. The best-fit results agree with each other and with experimental data thus validating both presented approaches. Copyright © 2013 The Author. Published by Elsevier B.V. All rights reserved.

  11. Photometric estimation of plutonium in product solutions and acid waste solutions using flow injection analysis technique

    International Nuclear Information System (INIS)

    Dhas, A.J.A.; Dharmapurikar, G.R.; Kumaraguru, K.; Vijayan, K.; Kapoor, S.C.; Ramanujam, A.

    1995-01-01

    Flow injection analysis technique is employed for the measurement of plutonium concentrations in product nitrate solutions by measuring the absorbance of Pu(III) at 565 nm and of Pu(IV) at 470 nm, using a Metrohm 662 photometer, with a pyrex glass tube of 2 nm (ID) inserted in the light path of the detector serving as a flow cell. The photometer detector never comes in contact with radioactive solution. In the case of acid waste solutions Pu is first purified by extraction chromatography with 2-ethyl hexyl hydrogen 2 ethyl hexyl phosphonate (KSM 17)- chromosorb and the Pu in the eluate in complexed with Arsenazo III followed by the measured of absorbance at 665 nm. Absorbance of reference solutions in the desired concentration ranges are measured to calibrate the system. The results obtained agree with the reference values within ±2.0%. (author). 3 refs., 1 tab

  12. Bienzymatic biosensor for rapid detection of aspartame by flow injection analysis.

    Science.gov (United States)

    Radulescu, Maria-Cristina; Bucur, Bogdan; Bucur, Madalina-Petruta; Radu, Gabriel Lucian

    2014-01-09

    A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX), carboxyl esterase (CaE) and bovine serum albumin (BSA) were immobilised with glutaraldehyde (GA) onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC). The biosensor response was fast. The sample throughput using a flow injection analysis (FIA) system was 40 h⁻¹ with an RSD of 2.7%. The detection limits for both batch and FIA measurements were 0.1 µM for methanol and 0.2 µM for aspartame, respectively. The enzymatic biosensor was successfully applied for aspartame determination in different sample matrices/commercial products (liquid and solid samples) without any pre-treatment step prior to measurement.

  13. Fundamental characteristics of droplet direct injection ICPMS for nano liter analysis

    International Nuclear Information System (INIS)

    Nakashima, N.; Miyahara, H.; Meguro, T.; Hotta, E.; Okino, A.

    2009-01-01

    Full text: Recently, target of the elemental analysis has been shifted to smaller amount samples such as bio cells or nano-particles. However, a conventional ICP system consumes large amount sample solutions, so it was not suitable for these samples. To realize much smaller sample introduction, a droplet direct injection nebulizer (D-DIN) system has been developed. In this study, we applied the D-DIN system to an ICPMS device. As a result, using a single 5 nL sample solution contains 1 mg/L of Na, Mg, Sr and Ba, mass signal of these elements were successfully obtained. Fundamental characteristics of D-DIN ICPMS will be presented. (author)

  14. Polydrug Use and HIV Risk Among People Who Inject Heroin in Tijuana, Mexico: A Latent Class Analysis.

    Science.gov (United States)

    Meacham, Meredith C; Rudolph, Abby E; Strathdee, Steffanie A; Rusch, Melanie L; Brouwer, Kimberly C; Patterson, Thomas L; Vera, Alicia; Rangel, Gudelia; Roesch, Scott C

    2015-01-01

    Although most people who inject drugs (PWID) in Tijuana, Mexico, primarily inject heroin, injection and non-injection use of methamphetamine and cocaine is common. We examined patterns of polydrug use among heroin injectors to inform prevention and treatment of drug use and its health and social consequences. Participants were PWID residing in Tijuana, aged ≥18 years who reported heroin injection in the past six months and were recruited through respondent-driven sampling (n = 1,025). Latent class analysis was conducted to assign individuals to classes on a probabilistic basis, using four indicators of past six-month polydrug and polyroute use: cocaine injecting, cocaine smoking or snorting, methamphetamine injecting, and methamphetamine smoking or snorting. Latent class membership was regressed onto covariates in a multinomial logistic regression. Latent class analyses testing 1, 2, 3, and 4 classes were fit, with the 3-class solution fitting best. Class 1 was defined by predominantly heroin use (50.2%, n = 515); class 2 by methamphetamine and heroin use (43.7%, n = 448), and class 3 by methamphetamine, cocaine, and heroin use (6.0%, n = 62). Bivariate and multivariate analyses indicated a group of methamphetamine and cocaine users that exhibited higher-risk sexual practices and lower heroin injecting frequency, and a group of methamphetamine users who were younger and more likely to be female. Discrete subtypes of heroin PWID were identified based on methamphetamine and cocaine use patterns. These findings have identified subtypes of heroin injectors who require more tailored interventions to reduce the health and social harms of injecting drug use.

  15. Modeling analysis of urea direct injection on the NOx emission reduction of biodiesel fueled diesel engines

    International Nuclear Information System (INIS)

    An, H.; Yang, W.M.; Li, J.; Zhou, D.Z.

    2015-01-01

    Highlights: • The effects of urea direct injection on NO x emissions reduction was investigated. • Aqueous urea solution was proposed to be injected after the fuel injection process. • The optimized injection strategy achieved a reduction efficiency of 58%. • There were no severe impacts on the CO emissions and BSFC. - Abstract: In this paper, a numerical simulation study was conducted to explore the possibility of an alternative approach: direct aqueous urea solution injection on the reduction of NO x emissions of a biodiesel fueled diesel engine. Simulation studies were performed using the 3D CFD simulation software KIVA4 coupled with CHEMKIN II code for pure biodiesel combustion under realistic engine operating conditions of 2400 rpm and 100% load. The chemical behaviors of the NO x formation and urea/NO x interaction processes were modeled by a modified extended Zeldovich mechanism and urea/NO interaction sub-mechanism. To ensure an efficient NO x reduction process, various aqueous urea injection strategies in terms of post injection timing, injection angle, and injection rate and urea mass fraction were carefully examined. The simulation results revealed that among all the four post injection timings (10 °ATDC, 15 °ATDC, 20 °ATDC and 25 °ATDC) that were evaluated, 15 °ATDC post injection timing consistently demonstrated a lower NO emission level. The orientation of the aqueous urea injection was also shown to play a critical role in determining the NO x removal efficiency, and 50 degrees injection angle was determined to be the optimal injection orientation which gave the most NO x reduction. In addition, both the urea/water ratio and aqueous urea injection rate demonstrated important roles which affected the thermal decomposition of urea into ammonia and the subsequent NO x removal process, and it was suggested that 50% urea mass fraction and 40% injection rate presented the lowest NO emission levels. At last, with the optimized injection

  16. The clinical value of Huangqi injection in the treatment of leucopenia: a meta-analysis of clinical controlled trials.

    Directory of Open Access Journals (Sweden)

    Changsong Zhang

    Full Text Available BACKGROUND: Huangqi injection is derived from Astragalus membranaceus root. In China, recent reports of Huangqi injection for the treatment of leucopenia have emerged. However, a systematic review of these reports has not been performed. Thus, we conducted a meta-analysis of clinical controlled trials to assess the clinical value of Huangqi injection in the treatment of leucopenia. METHODS: We searched the Chinese Biomedical Literature Database (CBM, Wanfang Database, China National Knowledge Infrastructure (CNKI, Chinese Scientific Journals Full-text Database (VIP, as well as PubMed and EMBASE to collect the data about trials of Huangqi injection for treating leucopenia. A meta-analysis was performed using RevMan 5.2 software. RESULTS: A total of 13 studies involving 841 patients were included in this study. The overall study quality was lower according to the Jadad scale. The meta-analysis showed that experimentally treated patients experienced greater therapeutic efficacy and lower white blood cell counts than control groups treated with Western medicine (P < 0.05. No publication bias was evident, according to Egger's test. CONCLUSIONS: The validity of this meta-analysis was limited by the overall poor quality of the included studies. Huangqi injection may have potential clinical value in the treatment of leucopenia, but confirmation with rigorously well-designed multi-center trials is needed.

  17. Design and Checking Analysis of Injection Mold for a Plastic Cup

    Science.gov (United States)

    Li, Xuebing

    2018-03-01

    A special injection mold was designed for the structural characteristics of a plastic cup part. The mold was simulated by Moldflow software and verified by calculating the stripping force, the pulling force and the clamping force of the mold so that to determine the appropriate injection parameters. It has been proved that the injection mold is effective and practical in the actual producing and can meet the quality requirements during the course of using it, which solved some problems for injection molding of this kind of parts and can provide some reference for the production of other products in the same industry.

  18. Hanford 100-N Area In Situ Apatite and Phosphate Emplacement by Groundwater and Jet Injection: Geochemical and Physical Core Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Szecsody, James E.; Vermeul, Vincent R.; Fruchter, Jonathan S.; Williams, Mark D.; Rockhold, Mark L.; Qafoku, Nikolla; Phillips, Jerry L.

    2010-07-01

    The purpose of this study is to evaluate emplacement of phosphate into subsurface sediments in the Hanford Site 100-N Area by two different technologies: groundwater injection of a Ca-citrate-PO4 solution and water-jet injection of sodium phosphate and/or fish-bone apatite. In situ emplacement of phosphate and apatite adsorbs, then incorporates Sr-90 into the apatite structure by substitution for calcium. Overall, both technologies (groundwater injection of Ca-citrate-PO4) and water-jet injection of sodium phosphate/fish-bone apatite) delivered sufficient phosphate to subsur¬face sediments in the 100-N Area. Over years to decades, additional Sr-90 will incorporate into the apatite precipitate. Therefore, high pressure water jetting is a viable technology to emplace phosphate or apatite in shallow subsurface sediments difficult to emplace by Ca-citrate-PO4 groundwater injections, but further analysis is needed to quantify the relevant areal extent of phosphate deposition (in the 5- to 15-ft distance from injection points) and cause of the high deposition in finer grained sediments.

  19. Post-injection delirium/sedation syndrome in patients with schizophrenia treated with olanzapine long-acting injection, I: analysis of cases

    Directory of Open Access Journals (Sweden)

    Stefaniak Victoria J

    2010-06-01

    Full Text Available Abstract Background An advance in the treatment of schizophrenia is the development of long-acting intramuscular formulations of antipsychotics, such as olanzapine long-acting injection (LAI. During clinical trials, a post-injection syndrome characterized by signs of delirium and/or excessive sedation was identified in a small percentage of patients following injection with olanzapine LAI. Methods Safety data from all completed and ongoing trials of olanzapine LAI were reviewed for possible cases of this post-injection syndrome. Descriptive analyses were conducted to characterize incidence, clinical presentation, and outcome. Regression analyses were conducted to assess possible risk factors. Results Based on approximately 45,000 olanzapine LAI injections given to 2054 patients in clinical trials through 14 October 2008, post-injection delirium/sedation syndrome occurred in approximately 0.07% of injections or 1.4% of patients (30 cases in 29 patients. Symptomatology was consistent with olanzapine overdose (e.g., sedation, confusion, slurred speech, altered gait, or unconsciousness. However, no clinically significant decreases in vital signs were observed. Symptom onset ranged from immediate to 3 to 5 hours post injection, with a median onset time of 25 minutes post injection. All patients recovered within 1.5 to 72 hours, and the majority continued to receive further olanzapine LAI injections following the event. No clear risk factors were identified. Conclusions Post-injection delirium/sedation syndrome can be readily identified based on symptom presentation, progression, and temporal relationship to the injection, and is consistent with olanzapine overdose following probable accidental intravascular injection of a portion of the olanzapine LAI dose. Although there is no specific antidote for olanzapine overdose, patients can be treated symptomatically as needed. Special precautions include use of proper injection technique and a post-injection

  20. Clinical analysis of intravitreal injection of Conbercept combined with 532-laser treating Coats disease in adulthood

    Directory of Open Access Journals (Sweden)

    Li Jiang

    2017-07-01

    Full Text Available AIM: To analyze clinical observation and the efficiency of intravitreal conbercept combined with 532-laser on Coats disease in adulthood. METHODS: This was an retrospective analysis. Six eyes from 6 patients(5 males and 1 femalewith coats disease diagnosed by fundus fluorescein angiography(FFAand optical coherence tomography(OCTwere enrolled. Before the injection, best-corrected visual acuity(BCVAof early treatment of diabetic retinopathy study(ETDRS, non-contact tonometer, ophthalmoscope, fundus photography, FFA, and OCT were examined. The initial average visual acuity(ETDRS letterswere 51.17±15.15. The initial average central retina thickness(CRTwas 303.30±107.87μm. All affected eyes were treated with intravitreal conbercept 0.05mL(10mg/mLcombined with 532-laser. Patients were followed up for 6 to 12mo, with a mean duration of 7.33±1.26mo. Post-treatment BCVA were compared with baseline using repeat analysis. RESULTS: The mean BCVA showed significant improvement during 1 wk, 1, 3mo post-treatment and the latest follow up(PCONCLUSION: Coats disease in adulthood more likely to have lower symptom and have a better response on treatment. Intravitreal conbercept combined with 532-laser significantly improve visual acuity and absorb the subretina fluid.

  1. Simultaneous injection effective mixing flow analysis of urinary albumin using dye-binding reaction.

    Science.gov (United States)

    Ratanawimarnwong, Nuanlaor; Ponhong, Kraingkrai; Teshima, Norio; Nacapricha, Duangjai; Grudpan, Kate; Sakai, Tadao; Motomizu, Shoji

    2012-07-15

    A new four-channel simultaneous injection effective mixing flow analysis (SIEMA) system has been assembled for the determination of urinary albumin. The SIEMA system consisted of a syringe pump, two 5-way cross connectors, four holding coils, five 3-way solenoid valves, a 50-cm long mixing coil and a spectrophotometer. Tetrabromophenol blue anion (TBPB) in Triton X-100 micelle reacted with albumin at pH 3.2 to form a blue ion complex with a λ(max) 625nm. TBPB, Triton X-100, acetate buffer and albumin standard solutions were aspirated into four individual holding coils by a syringe pump and then the aspirated zones were simultaneously pushed in the reverse direction to the detector flow cell. Baseline drift, due to adsorption of TBPB-albumin complex on the wall of the hydrophobic PTFE tubing, was minimized by aspiration of Triton X-100 and acetate buffer solutions between samples. The calibration graph was linear in the range of 10-50μg/mL and the detection limit for albumin (3σ) was 0.53μg/mL. The RSD (n=11) at 30μg/mL was 1.35%. The sample throughput was 37/h. With a 10-fold dilution, interference from urine matrix was removed. The proposed method has advantages in terms of simple automation operation and short analysis time. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Pharmacological prevention of rocuronium-induced injection pain or withdrawal movements: a meta-analysis.

    Science.gov (United States)

    Kwak, Hyun Jeong; Kim, Ji Young; Kim, Yong Beom; Min, Sang Kee; Moon, Bong Ki; Kim, Jong Yeop

    2013-10-01

    Rocuronium is reported to be associated with injection pain or withdrawal movement (IPWM). This meta-analysis assessed the efficacy of different pharmacological treatments used to decrease the incidence of the rocuronium-induced IPWM. We searched the Cochrane Library, Embase and PubMed for randomized controlled trials comparing a pharmacological drug with a placebo to prevent the rocuronium-induced IPWM and found 37 studies with 5,595 patients. Overall incidence of rocuronium-induced IPWM was 74%. Pretreatment with opioids [risk ratio (RR) 0.16; 95% confidence interval (95% CI) 0.09-0.29], lidocaine (0.47; 0.35-0.64), and ketamine (0.41; 0.22-0.77) were effective in decreasing IPWM. Lidocaine pretreatment with venous occlusion (0.40; 0.32-0.49) and opioids pretreatment with venous occlusion (0.77; 0.61-0.96) were also effective. Mixing sodium bicarbonate (NaHCO3) with rocuronium (0.15; 0.06-0.34) was also efficacious in reducing IPWM. Indirect comparison shows that the RR of NaHCO3 admixture and pretreatment with opioids were lower than that of the other four interventions (pretreatments of ketamine or lidocaine, and lidocaine or opioids with venous occlusion). This meta-analysis suggests that opioids, lidocaine, ketamine, and NaHCO3 are effective in decreasing rocuronium-induced IPWM. Considering the efficacy and convenience, pretreatment with opioids without venous occlusion is recommended for reducing rocuronium-induced IPWM.

  3. Review of recent applications of flow injection spectrophotometry to pharmaceutical analysis

    International Nuclear Information System (INIS)

    Tzanavaras, Paraskevas D.; Themelis, Demetrius G.

    2007-01-01

    Pharmaceutical analysis is one of the most important fields in analytical chemistry. The discovery of new drugs and the on-going update of international regulations for the safety and efficacy of pharmaceutical formulations demand the continuous development of new analytical methods. Inevitably, automation plays an important role, especially when a lot of samples have to be analyzed in the minimum of time. The present study reviews the applications of flow injection (FI) spectrophotometry to the determination of active pharmaceutical ingredients (APIs) in their respective formulations. However, the topic covered in this study is important not only to pharmaceutical analytical scientists. The principles, figures of merit and 'chemistry' of the presented methods can be of interest to bio-analytical and clinical chemists as well for the analysis of biological samples, to environmental analysts that study the up-to-date demand of the determination of the fate of pharmaceuticals in the environment and even to toxicologists and forensic scientists. This review covers scientific contributions published later than 2000. A variety of FI procedures based on homogeneous (direct UV measurements, colour-forming reactions, metal-drug interactions) and heterogeneous (optical sensors and solid-phase reactors) systems are discussed. A third section covers on-line sample pretreatment (solid-phase extraction, liquid-liquid extraction, on-line digestion, etc.)

  4. Flow Injection Analysis and Liquid Chromatography for Multifunctional Chemical Analysis (MCA) Systems

    Science.gov (United States)

    Mayo, Ana V.; Loegel, Thomas N.; Bretz, Stacey Lowery; Danielson, Neil D.

    2013-01-01

    The large class sizes of first-year chemistry labs makes it challenging to provide students with hands-on access to instrumentation because the number of students typically far exceeds the number of research-grade instruments available to collect data. Multifunctional chemical analysis (MCA) systems provide a viable alternative for large-scale…

  5. Analysis of dominant carrier recombination mechanisms depending on injection current in InGaN green light emitting diodes

    International Nuclear Information System (INIS)

    Kim, Kyu-Sang; Han, Dong-Pyo; Kim, Hyun-Sung; Shim, Jong-In

    2014-01-01

    Two kinds of green InGaN light emitting diodes (LEDs) have been investigated in order to understand the different slopes in logarithmic light output power-current (L-I) curves. Through the analysis of the carrier rate equation and by considering the carrier density-dependent the injection efficiency into quantum wells, the slopes of the logarithmic L-I curves can be more rigorously understood. The low current level, two as the tunneling current is initially dominant. The high current level beyond the peak of the external quantum efficiency (EQE) diminishes below one as the carrier overflow becomes dominant. In addition, the normalized carrier injection efficiency can be obtained by analyzing the slopes of the logarithmic L-I curves. The carrier injection efficiency decreases after the EQE peak of the InGaN LEDs, determined from the analysis of the slopes of the logarithmic L-I curves

  6. Transient performance analysis of pressurized safety injection tank with a partition

    International Nuclear Information System (INIS)

    Bae, Youngmin; Kim, Young In; Kim, Keung Koo

    2015-01-01

    Highlights: • Functional performance of safety injection tanks with a partition is evaluated. • Effects of key design parameters are scrutinized. • Distinctive features of the flow in multi-unit safety injection tanks are explored. - Abstract: A parametric study has been performed to evaluate the functional performance of a pressurized multi-unit safety injection tank, which would be considered as one of the candidates for a passive safety injection system in a nuclear power plant. The influences of key design parameters including the orifice size, initial gas fraction, and resistance coefficients and operating condition on the injection flow rate are scrutinized with a discussion of the relevant flow features such as the choked flow of gas through an orifice and two interconnected regions of differing gaseous pressure. The obtained results indicate that a multi-unit safety injection tank can passively control the injection flow rate and provide a stable safety injection over a relatively long period even in the case of drastic depressurization of a reactor coolant system

  7. Control, data acquisition and analysis for the JET neutral injection test bed

    International Nuclear Information System (INIS)

    Jones, T.T.C.; Brenan, P.R.; Rodgers, M.E.; Stork, D.; Young, I.D.

    1984-01-01

    The Neutral Injection Test-Bed (NITB) is a major experimental assembly in support of the Neutral Beam Heating Programme for JET. In addition to its prime function of testing the Neutral Injection hardware, the Test Bed serves as the prototype to test the computer control and data acquisition system, which is described. (author)

  8. The Efficacy of Danshen Injection as Adjunctive Therapy in Treating Angina Pectoris: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Shao, Huikai; Li, Mengsi; Chen, Fuchao; Chen, Lianghua; Jiang, Zhengjin; Zhao, Lingguo

    2018-04-01

    During the last 40 years, Danshen injection has been widely used as an adjunctive therapy for angina pectoris in China, but its efficacy is not yet well defined. The objective of this study was to verify the efficacy of Danshen injection as adjunctive therapy in treating angina pectoris. The major databases including PubMed, Cochrane Library, Sino-Med, Medline, Embase, Google Scholar, China National Knowledge Infrastructure, Wanfang Databases, Chinese Scientific Journal Database, Chinese Biomedical Literature Database and the Chinese Science Citation Database were systematically searched for the published randomised controlled trials (RCTs) on Danshen injection until April 2016. Meta-analysis was conducted on the primary outcomes (i.e., the improvements in symptoms and electrocardiography (ECG)). The quality of the included RCTs was evaluated with the M scoring system (the refined Jadad scale). Based on the quality, year of publication and sample size of RCTs, sensitivity analysis and subgroup analysis were performed in this study. Ten RCTs, including 944 anginal patients, were identified in this meta-analysis. Compared with using antianginal agents (β-blockers, calcium antagonists, nitrates, etc.) alone, Danshen injection combined with antianginal agents had a better therapeutic effect in symptom improvement (odds ratio [OR], 3.66; 95% confidence interval [CI]: 2.50-5.36) and in ECG improvement (OR, 3.25; 95% CI: 1.74-6.08). This study showed that Danshen injection as adjunctive therapy seemed to be more effective than antianginal agents alone in treating angina pectoris. However, more evidence is needed to accurately evaluate the efficacy of Danshen injection because of the low methodological quality of the included RCTs. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  9. The efficacy of multiple versus single hyaluronic acid injections: a systematic review and meta-analysis.

    Science.gov (United States)

    Concoff, Andrew; Sancheti, Parag; Niazi, Faizan; Shaw, Peter; Rosen, Jeffrey

    2017-12-21

    Intra-articular hyaluronic acid (IA-HA) is a common therapy used to treat knee pain and suppress knee inflammation in knee osteoarthritis (OA), typically prescribed in regimens ranging from a single injection to 5 weekly injections given once weekly. We conducted a systematic review to determine the efficacy of IA-HA, with subgroup analyses to explore the differences in knee pain and adverse events (AEs) across different dosing regimens. We conducted a systematic search of the literature to identify studies evaluating IA-HA for the management of knee OA compared to IA-saline. Primary outcome measure was the mean knee pain score at 13 Weeks (3 months) or 26 weeks (6 months). Secondary outcome was the number of treatment-related AEs and treatment-related serious adverse events (SAEs). We evaluated differences in levels of pain and AEs/SAEs between dosing regimens compared to IA-Saline. Thirty articles were included. Overall, IA-HA injections were associated with less knee pain compared to IA-Saline injections for all dosing regimens. 2-4 injections of IA-HA vs. IA-Saline produced the largest effect size at both 3-months and 6-months (Standard mean difference [SMD] = -0.76; -0.98 to -0.53, 95% CI, P injection studies yielded a non-significant treatment effect at 3 and 6 months, while ≥5 5 injections demonstrated a significant improvement in pain only at 6 months. Five or more injections of IA-HA were associated with a higher risk of treatment-related AEs compared to IA-Saline (Risk ratio [RR] = 1.67; 1.09 to 2.56 95% CI, p = 0.02), which was a result not seen within the 1 and 2-4 injection subgroups. Overall, 2-4 and ≥5 injection regimens provided pain relief over IA-Saline, while single injection did not. Intra-articular injections of HA used in a 2-4 injection treatment regimen provided the greatest benefit when compared to IA-Saline with respect to pain improvement in patients with knee OA, and was generally deemed safe with few to no

  10. Effect of pegaptanib sodium 0.3 mg intravitreal injections (Macugen) in intraocular pressure: posthoc analysis from VISION study

    NARCIS (Netherlands)

    Boyer, David S.; Goldbaum, Mauro; Leys, Anita M.; Starita, Carla; Blumenkranz, M.; Buyse, M.; Goldberg, M.; Gragoudas, E. S.; Miller, J.; Schwartz, S. D.; Singerman, L.; Yannuzzi, L.; Adamis, A. P.; Guyer, D. R.; O'Shaughnessy, D.; de Gronckel, S.; Fesneau, G.; Quinaux, E.; Tremolet, D.; Wang, K.; Brailey, A.; Finman, J.; Ting, N.; Bressler, N. M.; Bressler, S. B.; Denblow, R.; Schein, O. D.; Seabrook, S.; Solomon, S.; Schachat, A. P.; Philips, D.; Altaweel, M.; Davis, M. D.; Blodi, Ba; Danis, R. P.; Ip, M. S.; Hiner, C.; Elledge, J.; Webster, M.; Hannan, C.; Ficken, J.; Alexander, S.; Neider, M.; Wabers, H.; Vargo, P.; Lambert, E.; Kastorff, L.; Carr, A.; Shkiele, A.; Schlingemann, R. O.

    2014-01-01

    Objective To assess the rate of pegaptanib-associated sustained intraocular pressure (IOP) elevation. Methods A posthoc analysis was conducted on all IOP measurements, except the immediate 30-min postinjection, from all subjects randomised to pegaptanib 0.3 mg or sham injections continuously in the

  11. Mass spectrometric confirmation criterion for product-ion spectra generated in flow-injection analysis. Environmental application

    NARCIS (Netherlands)

    Geerdink, R.B.; Niessen, W.M.A.; Brinkman, U.A.T.

    2001-01-01

    The suitability of a confirmation criterion recently recommended in the Netherlands for gas chromatography with mass spectrometric detection (GC-MS), was evaluated for flow-injection analysis (FIA) with atmospheric pressure chemical ionisation MS-MS detection. The main feature of the criterion is

  12. Testosterone Injection

    Science.gov (United States)

    ... typical male characteristics. Testosterone injection works by supplying synthetic testosterone to replace the testosterone that is normally ... as a pellet to be injected under the skin.Testosterone injection may control your symptoms but will ...

  13. Analysis of ferrite heating of the LHC injection kickers and proposals for future reduction of temperature

    CERN Document Server

    Barnes, M J; Garrel, N; Goddard, B; Mertens, V; Weterings, W

    2012-01-01

    The two LHC injection kicker magnet (MKI) systems must produce a kick of 1.3 T.m with a flat top duration variable up to 7860 ns, and rise and fall times of less than 900 ns and 3000 ns, respectively. A beam screen is placed in the aperture of the magnets: the screen consists of a ceramic tube with conductors on the inner wall. The conductors provide a path for the image current of the high intensity LHC beam and screen the ferrite against wake fields. The conductors initially used gave adequately low beam coupling impedance however screen conductor discharges occurred during pulsing of the magnet; hence an alternative design with fewer screen conductors was implemented to meet the often conflicting requirements for low beam coupling impedance, fast magnetic field rise-time and good high voltage behaviour. During 2011 the LHC was operated with high intensity beam, coasting for many hours at a time, resulting in heating of the ferrite yoke of the MKIs. This paper presents an analysis of thermal measurement dat...

  14. Chinese Medicine Shenfu Injection for Heart Failure: A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Song Wen-Ting

    2012-01-01

    Full Text Available Objective. Heart failure (HF is a global public health problem. Early literature studies manifested that Shenfu injection (SFI is one of the most commonly used traditional Chinese patent medicine for HF in China. This article intended to systematically evaluate the efficacy and safety of SFI for HF. Methods. An extensive search was performed within 6 English and Chinese electronic database up to November 2011. Ninety-nine randomized controlled trails (RCTs were collected, irrespective of languages. Two authors extracted data and assessed the trial quality independently. RevMan 5.0.2 was used for data analysis. Results. Compared with routine treatment and/or device support, SFI combined with routine treatment and/or device support showed better effect on clinical effect rate, mortality, heart rate, NT-proBNP and 6-minute walk distance. Results in ultrasonic cardiography also showed that SFI combined with routine treatment improved heart function of HF patients. There were no significant difference in blood pressure between SFI and routine treatment groups. Adverse events were reported in thirteen trails with thirteen specific symptoms, while no serious adverse effect was reported. Conclusion. SFI appear to be effective for treating HF. However, further rigorously designed RCTs are warranted because of insufficient methodological rigor in the majority of included trials.

  15. Chinese medicine shenfu injection for heart failure: a systematic review and meta-analysis.

    Science.gov (United States)

    Wen-Ting, Song; Fa-Feng, Cheng; Li, Xu; Cheng-Ren, Lin; Jian-Xun, Liu

    2012-01-01

    Objective. Heart failure (HF) is a global public health problem. Early literature studies manifested that Shenfu injection (SFI) is one of the most commonly used traditional Chinese patent medicine for HF in China. This article intended to systematically evaluate the efficacy and safety of SFI for HF. Methods. An extensive search was performed within 6 English and Chinese electronic database up to November 2011. Ninety-nine randomized controlled trails (RCTs) were collected, irrespective of languages. Two authors extracted data and assessed the trial quality independently. RevMan 5.0.2 was used for data analysis. Results. Compared with routine treatment and/or device support, SFI combined with routine treatment and/or device support showed better effect on clinical effect rate, mortality, heart rate, NT-proBNP and 6-minute walk distance. Results in ultrasonic cardiography also showed that SFI combined with routine treatment improved heart function of HF patients. There were no significant difference in blood pressure between SFI and routine treatment groups. Adverse events were reported in thirteen trails with thirteen specific symptoms, while no serious adverse effect was reported. Conclusion. SFI appear to be effective for treating HF. However, further rigorously designed RCTs are warranted because of insufficient methodological rigor in the majority of included trials.

  16. Trace and ultratrace analysis methods for the determination of phosphorus by flow-injection techniques.

    Science.gov (United States)

    Motomizu, Shoji; Li, Zhen-Hai

    2005-04-15

    Trace (phosphorus determination by flow-injection analysis are reviewed. Most of the methods cited in this review are fundamentally based on the reaction of orthophosphate with molybdate to form heteropoly acids, such as molybdenum yellow and molybdenum blue, and some of the methods are based on the formation of such secondary reactions as ion associates and their aggregates with bulky cations, such as cationic dyes and quaternary ammonium ions. The heteropoly acids themselves can be measured by spectrophotometry, and the ion associate formed with a cationic dye, Malachite Green (MG), can be measured based on the coloration of MG. Light scattering detection methods can be used for measuring the aggregates of ion associates formed with bulky cations. Highly sensitive detection of phosphorus can be accomplished by fluorophotometry; Rhodamine B (RB) and its analogues react with molybdophosphate to form ion associates, which shows fluorescence quenching of RB: LOD is about 5 nM. The detection method based on the chemiluminescence of luminal oxidized with molybdophosphoric acids is probably the most sensitive of all the detection methods reported so far: LOD of the method is as low as 1nM. The LOD of the molybdenum blue method can be improved by using a liquid core waveguide: LOD is 0.5 nM.

  17. Enhanced Silver Nanoparticle Chemiluminescence Method for the Determination of Gemifloxacin Mesylate using Sequential Injection Analysis

    International Nuclear Information System (INIS)

    Alarfaj, N.A.; Aly, F.A.; Tamimi, A.A.

    2013-01-01

    A sequential injection analysis (SIA) with chemiluminescence detection has been proposed for the determination of the antibiotic gemifloxacin mesylate (GFX). The developed method is based on the enhancement effect of silver nanoparticles (Ag NPs) on the chemiluminescence (CL) signal of luminol-potassium ferricyanide reaction in alkaline medium. The introduction of gemifloxacin in this system produced a significant decrease in the CL intensity in presence of (Ag NPs). The optimum conditions for CL emission were investigated. Linear relationship between the decrease in CL intensity and concentration was obtained in the range 0.01-1000 ng mL-1, (r = 0.9997) with detection limit of 2.0 pg mL-1 and quantification limit of 0.01 pg mL-1. The relative standard deviation was 1.3 %. The proposed method was employed for the determination of gemifloxacin in bulk drug, in its pharmaceutical dosage forms and biological fluids such as human serum and urine. The interference of some common additive compounds such as glucose, lactose, starch, talc and magnesium stearate was investigated, and no interference was found from these excipients. The obtained SIA results were statistically compared with those obtained from a reported method and did not show any significant difference at confidence level 95%. (author)

  18. Flow regime analysis for fluid injection into a confined aquifer: implications for CO2 sequestration

    Science.gov (United States)

    Guo, B.; Zheng, Z.; Celia, M. A.; Stone, H.

    2015-12-01

    Carbon dioxide injection into a confined saline aquifer may be modeled as an axisymmetric two-phase flow problem. Assuming the two fluids segregate in the vertical direction due to strong buoyancy, and neglecting capillary pressure and miscibility, the lubrication approximation leads to a nonlinear advection-diffusion equation that describes the evolution of the sharp fluid-fluid interface. The flow behaviors in the system are controlled by two dimensionless groups: M, the viscosity ratio of the displaced fluid relative to injected fluid, and Γ , the gravity number, which represents the relative importance of buoyancy and fluid injection. Four different analytical solutions can be derived as the asymptotic approximations, representing specific values of the parameter pairs. The four solutions correspond to: (1) Γ 1; and (4) Γ >> 1, any M values. The first two of these solutions are new, while the third corresponds to the solution of Nordbotten and Celia (2006) for confined injections and the fourth corresponds to the solution of (Lyle et al., 2005) for gravity currents in an unconfined aquifer. Overall, the various axisymmetric flows can be summarized in a Γ-M regime diagram with five distinct dynamic behaviors including the four asymptotic regimes and an intermediate regime (Fig. 1). Data from a number of CO2 injection sites around the world can be used to compute the two dimensionless groups Γ and M associated with each injection. When plotted on the regime diagram, these values show the flow behavior for each injection and how the values vary from site to site. For all the CO2 injections, M is always larger than 1, while Γ can range from 0.01 up to 100. The pairs of (Γ, M) with lower Γ values correspond to solution (3), while the ones with higher Γ values can move up to the intermediate regime and the flow regime for solution (4). The higher values of Γ correspond to pilot-scale injections with low injection rates; most industrial-scale injection

  19. Control, data acquisition and analysis for the JET neutral injection test bed

    International Nuclear Information System (INIS)

    Jones, T.T.C.; Brenan, P.R.; Rodgers, M.E.; Stork, D.; Young, I.D.

    1985-01-01

    The Neutral Injection Test-Bed (NITB) is a major experimental assembly in support of the Neutral Beam Heating Programme for JET. In addition to its prime function of testing the Neutral Injection hardware, the Test Bed serves as the prototype to test the computer control and data acquisition system, which is described in this paper. The software system has been written in a portable, data-driven manner with the aim to adapt it, with only minor modifications to the operation of the first. Neutral Injection Beamline on JET, which will involve operation both synchronous and asynchronous with that of the JET Tokamak

  20. Analysis of bunch by bunch oscillations with bunch trains at injection into LHC at 25 ns bunch spacing

    CERN Document Server

    Bartosik, H

    2012-01-01

    An MD on August 26, 2011 was dedicated to injection studies of bunch trains with 25 ns spacing and nominal intensity of approximately 1×10(11) protons per bunch. Due to an electrical glitch, the MD was stopped after two attempts of injecting a train of 48 bunches for beam 2. Both injections were aborted after less than 0.1 s. In particular, the first attempt with transverse damper on was dumped after 1000 turns while the second attempt with transverse damper off was dumped after 500 turns only. In this note, an analysis of the bunch by bunch oscillation data recorded with the post-mortem system from the transverse damper is presented. The presented data clearly shows the presence of instabilities that affect mainly the second half of the batch. This is compatible with what would be expected qualitatively in the presence of the electron cloud effect.

  1. A microfabricated electroosmotic pump coupled to a gas-diffusion microchip for flow injection analysis of ammonia

    International Nuclear Information System (INIS)

    Zhu, Zaifang; Lu, Joann J.; Liu, Shaorong; Almeida, M. Inês G. S.; Kolev, Spas D.; Pu, Qiaosheng

    2015-01-01

    We have microfabricated two functional components toward developing a microchip flow injection analysis (FIA) system, i.e., an open-channel electroosmotic pump and a gas-diffusion chip, consisting of two microfabricated glass wafers and a porous polytetrafluoroethylene membrane. This is the first application of gas-diffusion separation in a microchip FIA system. To demonstrate the feasibility of using these two components for performing gas-diffusion FIA, we have incorporated them together with a regular FIA injection valve and a capillary electrophoresis absorbance detector in a flow injection system for determination of ammonia in environmental water samples. This system has a limit of detection of 0.10 mg L −1 NH 3 , with a good repeatability (relative standard deviation of less than 5 % for 4.0 mg L −1 NH 3 ). Parameters affecting its performance are also discussed. (author)

  2. Hospitalizations and economic analysis in psychotic patients with paliperidone palmitate long-acting injection.

    Science.gov (United States)

    Mesones-Peral, Jesús E; Gurillo-Muñoz, Pedro; Sánchez-Sicilia, Mari Paz; Miller, Adam; Griñant-Fernández, Alejandra

    Prevent hospitalizations in psychotic disorders is an important aim, so long-acting antipsychotic is a good option that can control better the correct adherence. Moreover, in the current economic context pharmacoeconomic studies are necessary. We estimate the effect in prevention of paliperidone palmitate long-acting injection (PP-LAI) and calculate the economic cost in the 12 months preceding the start of treatment with PP-LAI and 12 months later. Mirror image study of 71 outpatients diagnosed with psychotic disorders and treated with PP-LAI. In a first analysis, we measured along one year: number of hospitalizations/year, number of hospitalization in days, number of emergency assists/year and if there is antipsychotics associated to long-acting treatment. After this phase, we applied Fees Act of Valencia for economic analysis and estimate of the cost per hospitalization (€ 5,640.41) and hospital emergency (€ 187.61). After one year of treatment with PP-LAI (mean dose=130.65mg/month), we obtained greater numbers in assistance variables: total hospitalizations decrease, 78.8% (P=.009); shortening in hospitalization days, 89.4% (P=.009); abridgement of number of emergency assists, 79.1% (P=.002); decrease of rate of antipsychotics associated to long-acting treatment, 21% (P<.0001); increase in monotherapy, 53.8% (P<.0001). Therefore, after 12 months of treatment with PP-LAI we obtained a reduction in inpatient spending (savings of € 175,766.54) and increased spending on antipsychotics 32% (equivalent to € 151,126.92). PP-LAI can be an effective therapy for the treatment of patients with severe psychotic disorders: improves symptomatic stability and can prevent hospitalizations with cost-effective symptom control. Copyright © 2016 SEP y SEPB. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Fluid-structure interaction analysis of a water pool under loading caused by steam injection

    International Nuclear Information System (INIS)

    Timperi, A.; Paettikangas, T.; Niemi, J.; Ilvonen, M.

    2006-04-01

    CFD and structural analysis codes. MpCCI 3.0 was used for coupling Fluent CFD code with ABAQUS FE code. ES-FSI was used for coupling Star-CD CFD code with ABAQUS. FSI analyses, in which the calculation was carried out entirely in ABAQUS, were also performed. In this case, acoustic elements were used for the fluid and the acoustic and structural domains were coupled. FSI calculations were performed for simple test cases and for a test pool at Lappeenranta University of Technology. The Method of Images was studied as an alternative method for the analyses of the pool. Particularly, the determination of pressure source for the method was studied. Earlier work carried out with the homogenous two-phase model was continued by testing the model with Fluent. Calculation of condensation of steam in a water pool was tested with a new implementation. The two-directionally coupled simulations of the pool with MpCCI and ES-FSI were found to be numerically instable. It was concluded that an implicit coupling method may have to be used in order to avoid the instability. Calculations of the pool were finally performed by using one directional coupling. In the simulations with MpCCI, the incompressible and compressible VOF models of Fluent were used. With ES-FSI, the incompressible VOF model of Star-CD was used for modelling the beginning of a steam injection experiment. The magnitudes of pressure and stress peaks in the simulation and experiment were of comparable size. Otherwise, however, differences between the simulation and experiment were large due to the simplifications used in the simulation. Results obtained with the acoustic-structural FE analyses were compared to analytical and experimental results. The results indicated that the coupled acoustic-structural analysis can be used for calculating the coupled Eigenmodes of BWR pressure suppression pools. (au)

  4. Fluid-structure interaction analysis of a water pool under loading caused by steam injection

    Energy Technology Data Exchange (ETDEWEB)

    Timperi, A.; Paettikangas, T.; Niemi, J.; Ilvonen, M. [VTT Technical Researc Centre of Finland (Finland)

    2006-04-15

    CFD and structural analysis codes. MpCCI 3.0 was used for coupling Fluent CFD code with ABAQUS FE code. ES-FSI was used for coupling Star-CD CFD code with ABAQUS. FSI analyses, in which the calculation was carried out entirely in ABAQUS, were also performed. In this case, acoustic elements were used for the fluid and the acoustic and structural domains were coupled. FSI calculations were performed for simple test cases and for a test pool at Lappeenranta University of Technology. The Method of Images was studied as an alternative method for the analyses of the pool. Particularly, the determination of pressure source for the method was studied. Earlier work carried out with the homogenous two-phase model was continued by testing the model with Fluent. Calculation of condensation of steam in a water pool was tested with a new implementation. The two-directionally coupled simulations of the pool with MpCCI and ES-FSI were found to be numerically instable. It was concluded that an implicit coupling method may have to be used in order to avoid the instability. Calculations of the pool were finally performed by using one directional coupling. In the simulations with MpCCI, the incompressible and compressible VOF models of Fluent were used. With ES-FSI, the incompressible VOF model of Star-CD was used for modelling the beginning of a steam injection experiment. The magnitudes of pressure and stress peaks in the simulation and experiment were of comparable size. Otherwise, however, differences between the simulation and experiment were large due to the simplifications used in the simulation. Results obtained with the acoustic-structural FE analyses were compared to analytical and experimental results. The results indicated that the coupled acoustic-structural analysis can be used for calculating the coupled Eigenmodes of BWR pressure suppression pools. (au)

  5. Short-term cessation of sex work and injection drug use: evidence from a recurrent event survival analysis.

    Science.gov (United States)

    Gaines, Tommi L; Urada, Lianne A; Martinez, Gustavo; Goldenberg, Shira M; Rangel, Gudelia; Reed, Elizabeth; Patterson, Thomas L; Strathdee, Steffanie A

    2015-06-01

    This study quantitatively examined the prevalence and correlates of short-term sex work cessation among female sex workers who inject drugs (FSW-IDUs) and determined whether injection drug use was independently associated with cessation. We used data from FSW-IDUs (n=467) enrolled into an intervention designed to increase condom use and decrease sharing of injection equipment but was not designed to promote sex work cessation. We applied a survival analysis that accounted for quit-re-entry patterns of sex work over 1-year stratified by city, Tijuana and Ciudad Juarez, Mexico. Overall, 55% of participants stopped sex work at least once during follow-up. Controlling for other characteristics and intervention assignment, injection drug use was inversely associated with short-term sex work cessation in both cities. In Ciudad Juarez, women receiving drug treatment during follow-up had a 2-fold increase in the hazard of stopping sex work. In both cities, income from sources other than sex work, police interactions and healthcare access were independently and significantly associated with shorter-term cessation. Short-term sex work cessation was significantly affected by injection drug use. Expanded drug treatment and counseling coupled with supportive services such as relapse prevention, job training, and provision of alternate employment opportunities may promote longer-term cessation among women motivated to leave the sex industry. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. A Retrospective Analysis of Cyanoacrylate Injection versus Hemoclip Placement for Bleeding Dieulafoy’s Lesion in Duodenum

    Directory of Open Access Journals (Sweden)

    Yu Jiang

    2018-01-01

    Full Text Available Background. Duodenal Dieulafoy’s lesion (DL is a rare disease that may lead to lethal hemorrhage in the upper gastrointestinal tract. The best technique for endoscopic intervention still remains unclear. In the present study, we performed a retrospective analysis of cyanoacrylate injection versus hemoclip placement for treating bleeding DLs. Materials and Methods. We retrospectively analyzed eighteen patients from three medical centers between October 2008 and February 2016; six patients received cyanoacrylate injection, while hemoclips were placed in 12 patients during the upper gastrointestinal endoscopy. Results. All patients received first endoscopic examination and/or endotherapy within 12 hours of admission to hospital. No difference was observed in the primary hemostasis rate or the recurrent hemorrhage rate between the cyanoacrylate injection (CI group and the hemoclip placement (HP group, except that in one patient from the HP group melena was found three days after the first endotherapy. This patient received cyanoacrylate injection once again. Conclusion. Both cyanoacrylate injection and hemoclip placement are effective in treating duodenal DL, and neither of them causes significant side effects.

  7. A reavaluation of the reliability analysis of the low pressure injection system for Angra-1

    International Nuclear Information System (INIS)

    Oliveira, L.F.S. de; Fleming, P.V.; Frutuoso e Melo, P.F.F.; Tayt-Sohn, L.C.

    1983-01-01

    The emergency core cooling system of Angra 1 is analysed aiming at the low pressure injection systems, using the fault tree technique. All the failure mode of the components are considered for this analyse. (author) [pt

  8. Large-Scale Analysis of Remote Code Injection Attacks in Android Apps

    OpenAIRE

    Choi, Hyunwoo; Kim, Yongdae

    2018-01-01

    It is pretty well known that insecure code updating procedures for Android allow remote code injection attack. However, other than codes, there are many resources in Android that have to be updated, such as temporary files, images, databases, and configurations (XML and JSON). Security of update procedures for these resources is largely unknown. This paper investigates general conditions for remote code injection attacks on these resources. Using this, we design and implement a static detecti...

  9. Analysis of the Influence of Microcellular Injection Molding on the Environmental Impact of an Industrial Component

    Directory of Open Access Journals (Sweden)

    Daniel Elduque

    2014-09-01

    Full Text Available Microcellular injection molding is a process that offers numerous benefits due to the internal structure generated; thus, many applications are currently being developed in different fields, especially home appliances. In spite of the advantages, when changing the manufacturing process from conventional to microcellular injection molding, it is necessary to analyze its new mechanical properties and the environmental impact of the component. This paper presents a deep study of the environmental behavior of a manufactured component by both conventional and microcellular injection molding. Environmental impact will be evaluated performing a life cycle assessment. Functionality of the component will be also evaluated with samples obtained from manufactured components, to make sure that the mechanical requirements are fulfilled when using microcellular injection molding. For this purpose a special device has been developed to measure the flexural modulus. With a 16% weight reduction, the variation of flexural properties in the microcellular injected components is only 6.8%. Although the energy consumption of the microcellular injection process slightly increases, there is an overall reduction of the environmental burden of 14.9% in ReCiPe and 15% in carbon footprint. Therefore, MuCell technology can be considered as a green manufacturing technology for components working mainly under flexural load.

  10. Analysis of Serum Proteom after Intravenous Injection of cultivated wild ginseng pharmacopuncture

    Directory of Open Access Journals (Sweden)

    Dong-Hee,Lee

    2006-06-01

    Full Text Available Objectives : To observe the changes in the serum proteins after intravenous injection of cultivated wild ginseng pharmacopuncture. Methods : Blood was collected before and after the administration of cultivated wild ginseng pharmacopuncture and only the serum was taken. Then differences in the spots on the scanned image after carrying out 2-Dimensional electrophoresis were located and conducted mass analysis and protein identification. Results : Following results were obtained from the comparative analysis of serum proteins before and after the administration of cultivated wild ginseng pharmacopuncture. 1. 28 spots were identified before and after the administration. 2. In confirming manifestation degree, spots with more than two-times increase were 204, 1302, 2205, 3105, 7104, 8006, spots with more than one-time increase were 1101, 1505, 2013, 2403, 3009, 3010, 4002, 4009, 6704, 8101, and spots with decrease were 205, 801, 803, 3205, 5202, 6105, 6106, 7103, 9001, 9003. 3. After conducting protein identification, proteins 205, 804, 1302, 4009, 6105, 6106 are unidentified yet, and 1l01 is unnamed protein. Protein 204 is identified as complement receptor CR2-C3d, 801 as YAPl protein, 803 as antitrypsin polymer, 1505 as PRO0684, 2013 and 3010 as proapolipoprotein, 2205 as USP48, 2403 as vitamin D binding protein, 3009 as complement component 4A preprotein, 3105 as immunoglobulin lambda chain, 3205 as transthyretin, 4002 as Ras-related protein Ral-A, 4204 as beta actin, 5202 and 7104 as apolipoprotein Ll, 6704 as alpha 2 macroglobulin precursor, 7103 as complement component 3 precursor, 8006 as testis-specific protein Y, 8101 as transferrin, 9001 as (Alpha-Oxy, Beta-(Cl12gdeoxy T-State Human Hemoglobin, and 9003 as human hemoglobin. 4. Immune protein CR2-C3d(204, which acts against microbes and pathogenic organisms, was increased by more than two-times after the administration of pharmacopuncture. 5. Antitrypsin(803, which is secreted with

  11. Analysis of Serum proteom before and after Intravenous Injection of wild ginseng herbal acupuncture

    Directory of Open Access Journals (Sweden)

    Tae-Sik Kang

    2004-12-01

    Full Text Available Objectives : To observe changes in the serum proteins before and after intravenous injection of wild ginseng herbal acupuncture. Methods : Blood was collected before and after the administration of wild ginseng herbal acupuncture and only the serum was centrifuged. Then differences in the spots on the scanned image after running 2-Dimensional electrophoresis were located and conducted mass analysis and protein identification. Results : Following results were obtained from the comparative analysis of serum proteins before and after the administration of wild ginseng herbal acupuncture. 1. 28 spots were identified before and after the administration. 2. In confirming manifestation degree, spots with more than two-times increase were 204, 803, 1505, 2205, 3105, 7104, 9001 spots, with more than one-time increase were 1101, 1302, 2013, 3009, 3010, 4002, 4009, 6706, 7103, 8006, 8101, and spots with decrease were 205, 801, 3205, 5202, 6105. 3. After conducting protein identification, proteins 205, 804, 1302, 4009, 6105, 6106 are unidentified yet, and 1101 is unnamed protein. Protein 204 is identified as complement receptor CR2-C3d, 801 as YAP1 protein, 803 as antitrypsin polymer, 1505 as PRO0684, 2013 and 3010 as proapolipoprotein, 2205 as USP48, 2403 as vitamin D binding protein, 3009 as complement component 4A preprotein, 3105 as immunoglobulin lambda chain, 3205 as transthyretin, 4002 as Ras-related protein Ral-A, 4204 as beta actin, 5202 and 7104 as apolipoprotein L1, 6704 as alpha 2 macroglobulin precursor, 7103 as complement component 3 precursor, 8006 as testis-specific protein Y, 8101 as transferrin, 9001 as (Alpha-Oxy, Beta-(C112gdeoxy T-State Human Hemoglobin, and 9003 as human hemoglobin. 4. Immune protein CR2-C3d, which acts against microbes and pathogenic organisms, and Antitrypsin(803, which is secreted with inflammatory response in the lungs, were increased by more than 200% after the administration of herbal acupuncture. 5

  12. Experimental Analysis for Factors Affecting the Repeatability of Plastics Injection Molding Tests on the Self-developed Apparatus

    Directory of Open Access Journals (Sweden)

    Yugang Huang

    2013-06-01

    Full Text Available Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 To improve the repeatability of the injection molding test result, the affecting factors were investigated by means of experiments. Besides the traditional processing parameter, the factors of test conditions were also considered. In order to focus on the molding process rather than the molded part, the curve measurement of the melt pressure at the entrance to the nozzle was used as the output characteristic. Experiments for polypropylene (PP showed that the injected volume was the key processing parameter. Within the test conditions, the injection number is the most important factor. According to the analysis the operating procedure was improved effectively. Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 Doi: 10.12777/ijse.5.1.6-11 [How to cite this article: Huang, Y., Li, D., Liu, Y. (2013. Experimental Analysis for Factors Affecting the Repeatability of Plastics Injection Molding Tests on the Self-developed Apparatus. International Journal of Science and Engineering, 5(1,6-11. Doi: 10.12777/ijse.5.1.6-11]

  13. Metagenomic analysis indicates Epsilonproteobacteria as a potential cause of microbial corrosion in pipelines injected with bisulfite

    Directory of Open Access Journals (Sweden)

    Dongshan eAn

    2016-01-01

    Full Text Available Sodium bisulfite (SBS is used as an oxygen scavenger to decrease corrosion in pipelines transporting brackish subsurface water used in the production of bitumen by steam-assisted gravity drainage. Sequencing 16S rRNA gene amplicons has indicated that SBS addition increased the fraction of the sulfate-reducing bacteria (SRB Desulfomicrobium, as well as of Desulfocapsa, which can also grow by disproportionating sulfite into sulfide, sulfur and sulfate. SRB use cathodic H2, formed by reduction of aqueous protons at the iron surface, or use low potential electrons from iron and aqueous protons directly for sulfate reduction. In order to reveal the effects of SBS treatment in more detail, metagenomic analysis was performed with pipe-associated solids (PAS scraped from a pipe section upstream (PAS-616P and downstream (PAS-821TP of the SBS injection point. A major SBS-induced change in microbial community composition and in affiliated hynL genes for the large subunit of [NiFe] hydrogenase was the appearance of sulfur-metabolizing Epsilonproteobacteria of the genera Sulfuricurvum and Sulfurovum. These are chemolithotrophs, which oxidize sulfide or sulfur with O2 or reduce sulfur with H2. Because O2 was absent, this class likely catalyzed reduction of sulfur (S0 originating from the metabolism of bisulfite with cathodic H2 (or low potential electrons and aqueous protons originating from the corrosion of steel (Fe0. Overall this accelerates reaction of of S0 and Fe0 to form FeS, making this class a potentially powerful contributor to microbial corrosion. The PAS-821TP metagenome also had increased fractions of Deltaproteobacteria including the SRB Desulfomicrobium and Desulfocapsa. Altogether, SBS increased the fraction of hydrogen-utilizing Delta- and Epsilonproteobacteria in brackish-water-transporting pipelines, potentially stimulating anaerobic pipeline corrosion if dosed in excess of the intended oxygen scavenger function.

  14. An electrochemiluminescence-based fibre optic biosensor for choline flow injection analysis.

    Science.gov (United States)

    Tsafack, V C; Marquette, C A; Leca, B; Blum, L J

    2000-01-01

    A fibre optic biosensor based on luminol electrochemiluminescence (ECL) integrated in a flow injection analysis (FIA) system was developed for the detection of choline. The electrochemiluminescence of luminol was generated by a glassy carbon electrode polarised at +425 mV vs. a platinum pseudo-reference electrode. Choline oxidase (Chx) was immobilised either covalently on polyamide (ABC type) or on UltraBind preactivated membranes, or by physical entrapment in a photo-cross-linkable poly(vinyl alcohol) polymer (PVA-SbQ) alone or after absorption on a weak anion exchanger, DEAE (diethylaminoethyl) Sepharose. The optimisation of the reaction conditions and physicochemical parameters influencing the FIA biosensor response demonstrated that the choline biosensor exhibited the best performances in a 30 mM veronal buffer containing 30 mM KCl and 1.5 mM MgCl2, at pH 9. The use of a 0.5 ml min-1 flow rate enabled the measurement of choline by the membrane-based ECL biosensors in 8 or 5 min, with ABC or UltraBind membranes, respectively, whereas the measurement required only 3 min with the DEAE-PVA system. For comparison, the detection of choline was performed with Chx immobilised using the four different supports. The best performances were obtained with the DEAE-PVA-Chx sensing layer, which allowed a detection limit of 10 pmol, whereas with the ABC, the UltraBind and the PVA systems, the detection limits were 300 pmol, 75 pmol and 220 pmol, respectively. The DEAE-based system also exhibited a good operational stability since 160 repeated measurements of 3 nmol of choline could be performed with an RSD of 4.5% whereas the stability under the best conditions was 45 assays with the other supports.

  15. Development of a Sequential Injection Analysis System for the Determination of Saccharin

    Directory of Open Access Journals (Sweden)

    Budi Wibowotomo

    2017-12-01

    Full Text Available Saccharin is a powerfully sweet nonnutritive sweetener that has been approved for food-processing applications within the range of 100–1200 mg/kg. A simple, rapid, and cost-effective sequential injection analysis (SIA technique was developed to determine the saccharin level. This method is based on the reaction of saccharin with p-chloranil in an ethanol medium with a hydrogen peroxide (H2O2 acceleration, and the resultant violet-red compound was detected using a UV-Vis spectrophotometer at λmax = 420 nm. To ascertain the optimal conditions for the SIA system, several parameters were investigated, including buffer flow rate and volume, p-chloranil concentration, and reactant volumes (saccharin, p-chloranil, and H2O2. The optimum setup of the SIA system was achieved with a buffer flow rate, buffer volume, and draw-up time of 1.2 mL/min, 2900 µL, and ~145 s, respectively. The optimal p-chloranil concentration is 30 mM, and the best reactant volumes, presented in an ordered sequence, are as follows: 30 µL of H2O2, 450 µL of saccharin, and 150 µL of p-chloranil. The optimized SIA configuration produced a good linear calibration curve with a correlation coefficient (R2 = 0.9812 in the concentration range of 20–140 mg/L and with a detection limit of 19.69 mg/L. Analytical applications in different food categories also showed acceptable recovery values in the range of 93.1–111.5%. This simple and rapid SIA system offers great feasibility for the saccharin quality control in food-product processing.

  16. Development of a Sequential Injection Analysis System for the Determination of Saccharin.

    Science.gov (United States)

    Wibowotomo, Budi; Eun, Jong-Bang; Rhee, Jong Il

    2017-12-12

    Saccharin is a powerfully sweet nonnutritive sweetener that has been approved for food-processing applications within the range of 100-1200 mg/kg. A simple, rapid, and cost-effective sequential injection analysis (SIA) technique was developed to determine the saccharin level. This method is based on the reaction of saccharin with p-chloranil in an ethanol medium with a hydrogen peroxide (H₂O₂) acceleration, and the resultant violet-red compound was detected using a UV-Vis spectrophotometer at λ max = 420 nm. To ascertain the optimal conditions for the SIA system, several parameters were investigated, including buffer flow rate and volume, p-chloranil concentration, and reactant volumes (saccharin, p-chloranil, and H₂O₂). The optimum setup of the SIA system was achieved with a buffer flow rate, buffer volume, and draw-up time of 1.2 mL/min, 2900 µL, and ~145 s, respectively. The optimal p-chloranil concentration is 30 mM, and the best reactant volumes, presented in an ordered sequence, are as follows: 30 µL of H₂O₂, 450 µL of saccharin, and 150 µL of p-chloranil. The optimized SIA configuration produced a good linear calibration curve with a correlation coefficient (R² = 0.9812) in the concentration range of 20-140 mg/L and with a detection limit of 19.69 mg/L. Analytical applications in different food categories also showed acceptable recovery values in the range of 93.1-111.5%. This simple and rapid SIA system offers great feasibility for the saccharin quality control in food-product processing.

  17. Analysis of gas turbine engines using water and oxygen injection to achieve high Mach numbers and high thrust

    Science.gov (United States)

    Henneberry, Hugh M.; Snyder, Christopher A.

    1993-01-01

    An analysis of gas turbine engines using water and oxygen injection to enhance performance by increasing Mach number capability and by increasing thrust is described. The liquids are injected, either separately or together, into the subsonic diffuser ahead of the engine compressor. A turbojet engine and a mixed-flow turbofan engine (MFTF) are examined, and in pursuit of maximum thrust, both engines are fitted with afterburners. The results indicate that water injection alone can extend the performance envelope of both engine types by one and one-half Mach numbers at which point water-air ratios reach 17 or 18 percent and liquid specific impulse is reduced to some 390 to 470 seconds, a level about equal to the impulse of a high energy rocket engine. The envelope can be further extended, but only with increasing sacrifices in liquid specific impulse. Oxygen-airflow ratios as high as 15 percent were investigated for increasing thrust. Using 15 percent oxygen in combination with water injection at high supersonic Mach numbers resulted in thrust augmentation as high as 76 percent without any significant decrease in liquid specific impulse. The stoichiometric afterburner exit temperature increased with increasing oxygen flow, reaching 4822 deg R in the turbojet engine at a Mach number of 3.5. At the transonic Mach number of 0.95 where no water injection is needed, an oxygen-air ratio of 15 percent increased thrust by some 55 percent in both engines, along with a decrease in liquid specific impulse of 62 percent. Afterburner temperature was approximately 4700 deg R at this high thrust condition. Water and/or oxygen injection are simple and straightforward strategies to improve engine performance and they will add little to engine weight. However, if large Mach number and thrust increases are required, liquid flows become significant, so that operation at these conditions will necessarily be of short duration.

  18. Numerical Analysis of the Combustion and Emission Characteristics of Diesel Engines with Multiple Injection Strategies Using a Modified 2-D Flamelet Model

    Directory of Open Access Journals (Sweden)

    Gyujin Kim

    2017-08-01

    Full Text Available The multiple injection strategy has been widely used in diesel engines to reduce engine noise, NOx and soot formation. Fuel injection developments such as the common-rail and piezo-actuator system provide more precise control of the injection quantity and time under higher injection pressures. As various injection strategies become accessible, it is important to understand the interaction of each fuel stream and following combustion process under the multiple injection strategy. To investigate these complex processes quantitatively, numerical analysis using CFD is a good alternative to overcome the limitation of experiments. A modified 2-D flamelet model is further developed from previous work to model multi-fuel streams with higher accuracy. The model was validated under various engine operating conditions and captures the combustion and emissions characteristics as well as several parametric variations. The model is expected to be used to suggest advanced injection strategies in engine development processes.

  19. Analysis of emergency core cooling capability of direct vessel vertical injection using CFX

    International Nuclear Information System (INIS)

    Yoon, Sang H.; Yu, Yong H.; Suh, Kune Y.

    2003-01-01

    More reliable and efficient safety injection system is of utmost importance in the design of advanced reactors such as the APR1400 (Advanced Power Reactor 1400 MWe). In this work, a new idea is proposed to inject the Emergency Core Cooling (ECC) water utilizing a dedicated nozzle with a vertically downward elbow. The Direct Vessel Injection (DVI) system is located horizontally above the cold leg in the APR1400. However, the horizontal injection method may not always satisfy the ECC penetration requirement into the core on account of rather involved multidimensional thermal and hydraulic phenomena occurring in the annular reactor downcomer such as bypass, impingement, entrainment and sweepout, condensation oscillation, etc. Thus, a novel concept is called for from the reactor safety point of view. The Direct Vessel Vertical Injection (DVVI) system is one of these efforts to penetrate as much the ECC water through the downcomer into the core as is practically achievable. The DVVI system can increase the momentum of the downward flow, thus minimizing the effect of water impingement on the core barrel and the direct bypass though the break. To support the claim of increased downward momentum of flow in the DVVI system, computational fluid dynamics analyses were performed using CFX. The new concept of the DVVI system, which can certainly help increase the core thermal margin, is found to be more efficient than DVI. If the structural problem in the manufacturing process is properly solved, this concept can safely be applied in the advanced nuclear reactor design

  20. Clinical application analysis of andrographolide total ester sulfonate injection, a traditional Chinese medicine licensed in China.

    Science.gov (United States)

    Zhao, Ying; Huang, Pu; Chen, Zhe; Zheng, Si-Wei; Yu, Jin-Yang; Shi, Chen

    2017-04-01

    Andrographolide total ester sulfonate (ATES) injection is one of the products of traditional Chinese medicine (TCM) currently used against viral infection in China. ATES injection was approved for manufacturing and marketing in January 2002. It is indicated for acute respiratory infections, tonsillitis, chronic obstructive pulmonary disease, influenza, foot and mouth disease, bronchiolitis, herpangina, mumps, infectious mononucleosis and psychosis. However, its usage also carries risk. We investigated the use of ATES at the Wuhan Union Hospital from January 2014 to December 2014 and evaluated its real-world clinical application using the hospital centralized monitoring method. A total of 848 cases were enrolled in this study. In these cases, it was mainly used for postoperative anti-inflammation and treating upper respiratory infection, pneumonia and bronchitis. Among them, 39.86% were contraindicated. Irregular medication of adults and children accounted for 1.91% and 23.38%, respectively. Improper choice of solvent accounted for 3.18%. The choice of intravenous drip versus aerosol inhalation was reasonable. A case of adverse events (AEs) was observed in the monitoring period, and the incidence of adverse drug reaction (ADR) of ATES injection was 0.12%. ATES injection in our hospital is relatively safe with a low incidence of adverse reactions. The study assesses the clinical usage and adverse reactions of ATES injection, and provides suggestions for rational use in clinical practice.

  1. Comparative effectiveness of injection therapies in lateral epicondylitis: a systematic review and network meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Krogh, Thøger Persson; Bartels, Else Marie; Ellingsen, Torkell; Stengaard-Pedersen, Kristian; Buchbinder, Rachelle; Fredberg, Ulrich; Bliddal, Henning; Christensen, Robin

    2013-06-01

    Injection therapy with glucocorticoids has been used since the 1950s as a treatment strategy for lateral epicondylitis (tennis elbow). Lately, several novel injection therapies have become available. To assess the comparative effectiveness and safety of injection therapies in patients with lateral epicondylitis. Systematic review and meta-analysis. Randomized controlled trials comparing different injection therapies for lateral epicondylitis were included provided they contained data for change in pain intensity (primary outcome). Trials were assessed using the Cochrane risk of bias tool. Network (random effects) meta-analysis was applied to combine direct and indirect evidence within and across trial data using the final end point reported in the trials, and results for the arm-based network analyses are reported as standardized mean differences (SMDs). Seventeen trials (1381 participants; 3 [18%] at low risk of bias) assessing injection with 8 different treatments-glucocorticoid (10 trials), botulinum toxin (4 trials), autologous blood (3 trials), platelet-rich plasma (2 trials), and polidocanol, glycosaminoglycan, prolotherapy, and hyaluronic acid (1 trial each)-were included. Pooled results (SMD [95% confidence interval]) showed that beyond 8 weeks, glucocorticoid injection was no more effective than placebo (-0.04 [-0.45 to 0.35]), but only 1 trial (which did not include a placebo arm) was at low risk of bias. Although botulinum toxin showed marginal benefit (-0.50 [-0.91 to -0.08]), it caused temporary paresis of finger extension, and all trials were at high risk of bias. Both autologous blood (-1.43 [-2.15 to -0.71]) and platelet-rich plasma (-1.13 [-1.77 to -0.49]) were also statistically superior to placebo, but only 1 trial was at low risk of bias. Prolotherapy (-2.71 [-4.60 to -0.82]) and hyaluronic acid (-5.58 [-6.35 to -4.82]) were both more efficacious than placebo, whereas polidocanol (0.39 [-0.42 to 1.20]) and glycosaminoglycan (-0.32 [-1.02 to 0

  2. Economic Analysis of Additive Manufacturing Integration in Injection Molding Process Chain

    DEFF Research Database (Denmark)

    Charalambis, Alessandro; Kerbache, Laoucine; Tosello, Guido

    The purpose of this research is to analyze how additive manufacturing can create value when it is utilized as a supportive technology to injection molding by quantifying the cost advantages that can be obtained. Tooling for the product development phase is investigated as pilot integration area...... of additive manufacturing with injection molding. Cost considerations are discussed through the development of a cost estimation model. The study shows that integration of additive manufacturing in the product development phase for fabrication of soft tooling is economically convenient with a cost reduction...... of 79,8% and 89,9%. The cost models on additive manufacturing have been built so far on the idea of substituting injection molding with additive manufacturing. In response to this literature gap, this research addresses the advantages of additive manufacturing utilized in a synergistic rather than...

  3. Large-Scale Analysis of Remote Code Injection Attacks in Android Apps

    Directory of Open Access Journals (Sweden)

    Hyunwoo Choi

    2018-01-01

    Full Text Available It is pretty well known that insecure code updating procedures for Android allow remote code injection attack. However, other than codes, there are many resources in Android that have to be updated, such as temporary files, images, databases, and configurations (XML and JSON. Security of update procedures for these resources is largely unknown. This paper investigates general conditions for remote code injection attacks on these resources. Using this, we design and implement a static detection tool that automatically identifies apps that meet these conditions. We apply the detection tool to a large dataset comprising 9,054 apps, from three different types of datasets: official market, third-party market, and preinstalled apps. As a result, 97 apps were found to be potentially vulnerable, with 53 confirmed as vulnerable to remote code injection attacks.

  4. Analysis of limited fertility in intracytoplasmic sperm injection of sperm obtained by electroejaculation

    Science.gov (United States)

    Nakamura, Yoshihiro; Kitamura, Masaya; Nishimura, Kenji; Tsujimura, Akira; Takeyama, Masami; Kondoh, Nobuyuki; Miyazaki, Kazunori; Okuyama, Akihiko

    2004-01-01

    Background and Aims:  We correlated findings in semen from patients with ejaculatory dysfunction with results of in vitro fertilization using their electroejaculated sperm. Methods and Results:  Electroejaculation was carried out in six patients with the above‐mentioned criteria for a total of eight times. Sperm was obtained in six attempts. Intracytoplasmic injection of these sperm was performed in 156 eggs. Sixty‐seven eggs were fertilized; most of these were injected with motile sperm. Two women became pregnant, both after injection with motile sperm. As previously reported, electroejaculated sperm showed low motility and a low fertilization rate, but even motile sperm had a low fertilization rate. Conclusion:  The results of the present study suggest the importance in fertilization of undetermined factors in addition to sperm motility. (Reprod Med Biol 2004; 3: 9–12) PMID:29662380

  5. [Registration study on analysis of adaptation syndromes and medication characteristics of tanreqing injection].

    Science.gov (United States)

    Xie, Peng-Yang; Xie, Yan-Ming; Wang, Lian-Xin; Chang, Yan-Peng; You, Li; Zhang, Xiao-Li

    2014-09-01

    Tanreqing injection is suitable for early pneumonia, acute bronchitis, acute exacerbations of chronic, and upper respiratory tract infection which are classified with phlegm-heat obstructing lung syndrome of traditional Chinese medicine. To understand the clinical adaptation syndromes and medication characteristics of the post-market Tanreqing injection, the research team of the paper monitored the patients who are used with Tanreqing injection from September 2012 to October 2013 in four leader hospitals based on the method--prospective, multi-center, large sample, registration-type hospital centralized monitoring,and analyzes the general information, diagnostic information and medication characteristics of patients, in order to produce evidence for clinical practice and medication decisions and to establish the foundation of rational drug use.

  6. Comparative analysis of anterior and posterior contrast injection approaches for shoulder MR arthrograms in adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Gupton, Theodore B.; Cahill, Anne M. [The Children' s Hospital of Philadelphia, Division of Interventional Radiology, Department of Radiology, Philadelphia, PA (United States); Delgado, Jorge [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Jaramillo, Diego [Stanford University Medical Center, Diagnostic Radiology, Palo Alto, CA (United States); Chauvin, Nancy A. [The Children' s Hospital of Philadelphia, Perelman School of Medicine at the University of Pennsylvania, Musculoskeletal Imaging, Department of Radiology, Philadelphia, PA (United States)

    2016-12-15

    There is no consensus in the literature concerning the optimal approach for performing a fluoroscopically guided shoulder arthrogram injection in a pediatric population. To compare adequacy of capsular injection and radiation doses between fluoroscopically guided anterior and posterior glenohumeral joint contrast injections in adolescents. We evaluated imaging in 67 adolescents (39 boys, 28 girls; mean age 16.0 years; range 11.7-19.1 years) who underwent an anterior approach glenohumeral contrast injection with subsequent MR imaging, and 67 age- and gender-matched subjects (39 boys, 28 girls; mean age 16.0 years; range 11.1-19.2 years) who underwent a posterior approach injection during the period June 2010 to September 2015. Two pediatric radiologists independently evaluated all MR shoulder arthrograms to assess adequacy of capsular distention and degree of contrast extravasation. We recorded total fluoroscopic time, dose-area product (DAP) and cumulative air kerma (CAK). There were no significant differences in age, gender, height, weight or body mass index between the populations (P-values > 0.6). The amount of contrast extravasation between the groups was not significantly different (P = 0.27). Three anterior injections (4.5%) and one posterior (1.5%) were suboptimal (P = 0.62). Fluoroscopy time was not different: 1.1 min anterior and 1.3 min posterior (P = 0.14). There was a significant difference in CAK (0.7 mGy anterior and 1.1 mGy posterior; P = 0.007) and DAP (5.3 μGym{sup 2} anterior and 9.4 μGym{sup 2} posterior; P = 0.008). Inter-rater agreement was excellent (Cohen kappa >0.81). Both techniques were technically successful. There was no difference in the fluoroscopy time for either approach. The radiation dose was higher with the posterior approach but this is of questionable clinical significance. (orig.)

  7. Injectable loop recorder implantation in an ambulatory setting by advanced practice providers: Analysis of outcomes.

    Science.gov (United States)

    Kipp, Ryan; Young, Natasha; Barnett, Anne; Kopp, Douglas; Leal, Miguel A; Eckhardt, Lee L; Teelin, Thomas; Hoffmayer, Kurt S; Wright, Jennifer; Field, Michael

    2017-09-01

    Implantable loop recorder (ILR) insertion has historically been performed in a surgical environment such as the electrophysiology (EP) lab. The newest generation loop recorder (Medtronic Reveal LINQ™, Minneapolis, MN, USA) is injectable with potential for implantation in a non-EP lab setting by advanced practice providers (APPs) facilitating improved workflow and resource utilization. We report the safety and efficacy of injectable ILR placement in the ambulatory care setting by APPs. A retrospective review was performed including all patients referred for injectable ILR placement from March 2014 to November 2015. All device placement procedures were performed in an ambulatory care setting using the standard manufacturer deployment kit with sterile technique and local anesthetic following a single dose of intravenous antibiotics. Acute procedural success and complication rates following injectable ILR placement in the ambulatory setting were reviewed. During the study period, 125 injectable ILRs were implanted. Acute procedural success with adequate sensing (R-waves ≥ 0.2 mV) occurred in 100% of patients. There were no acute procedural complications. Subacute complications occurred in two patients (1.6% of implantations), including one possible infection treated with oral antibiotics and one device removal due to pain at the implant site. In this retrospective single-center study, implantation of injectable ILR in an ambulatory care setting by APPs following a single dose of intravenous antibiotics and standard manufacturer technique yielded a low complication rate with high acute procedural success. Use of this implantation strategy may improve EP lab workflow while providing a safe and effective technique for device placement. © 2017 Wiley Periodicals, Inc.

  8. Analysis of radiochemical purity (RCP) of 99Tcm-MAG3 injection

    International Nuclear Information System (INIS)

    Huang Qingquan; Xia Zhenmin

    1992-01-01

    A two-system paper chromatographic method has been established for the determination of RCP of 99 Tc m -MAG 3 injection. R f -values of 99 Tc m -MAG 3 , 99 Tc m O 4 - and H-R- 99 Tc m (hydrolysis reduced 99 Tc m ) are 0.9, 0.8, 0.0 in system I, and 0.0, 0.4, 0.0 in system II respectively. The RCP and percentages of 99 Tc m O 4 - and H-R- 99 Tc m of 99 Tc m -MAG 3 injection have been determined with this method

  9. The analysis of scaling mechanism for water-injection pipe columns in the Daqing Oilfield

    OpenAIRE

    Jing, Guolin; Tang, Shan; Li, Xiaoxiao; Wang, Huaiyuan

    2013-01-01

    Although water-injection in mature reservoirs is a promising low-cost method of enhanced oil recovery (EOR), in the process of development in the oilfield, scale has been produced in water-injection pipe columns. The ability to prevent and control the deposition of scale is critical to the efficient recovery of crude oil from hard environments, as part of the broader discipline of “flow assurance” in the petroleum industry. To this end laboratory-scale deposition tests have been useful to und...

  10. Developing the Model of Fuel Injection Process Efficiency Analysis for Injector for Diesel Engines

    Science.gov (United States)

    Anisimov, M. Yu; Kayukov, S. S.; Gorshkalev, A. A.; Belousov, A. V.; Gallyamov, R. E.; Lysenko, Yu D.

    2018-01-01

    The article proposes an assessment option for analysing the quality of fuel injection by the injector constituting the development of calculation blocks in a common injector model within LMS Imagine.Lab AMESim. The parameters of the injector model in the article correspond to the serial injector Common Rail-type with solenoid. The possibilities of this approach are demonstrated with providing the results using the example of modelling the modified injector. Following the research results, the advantages of the proposed approach to analysing assessing the fuel injection quality were detected.

  11. Analysis of selected antibiotics in surface freshwater and seawater using direct injection in liquid chromatography electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Bayen, Stéphane; Yi, Xinzhu; Segovia, Elvagris; Zhou, Zhi; Kelly, Barry C

    2014-04-18

    Emerging contaminants such as antibiotics have received recent attention as they have been detected in natural waters and health concerns over potential antibiotic resistance. With the purpose to investigate fast and high-throughput analysis, and eventually the continuous on-line analysis of emerging contaminants, this study presents results on the analysis of seven selected antibiotics (sulfadiazine, sulfamethazine, sulfamerazine, sulfamethoxazole, chloramphenicol, lincomycin, tylosin) in surface freshwater and seawater using direct injection of a small sample volume (20μL) in liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). Notably, direct injection of seawater in the LC-ESI-MS/MS was made possible on account of the post-column switch on the system, which allows diversion of salt-containing solutions flushed out of the column to the waste. Mean recoveries based on the isotope dilution method average 95±14% and 96±28% amongst the compounds for spiked freshwater and seawater, respectively. Linearity across six spiking levels was assessed and the response was linear (r(2)>0.99) for all compounds. Direct injection concentrations were compared for real samples to those obtained with the conventional SPE-based analysis and both techniques concurs on the presence/absence and levels of the compounds in real samples. These results suggest direct injection is a reliable method to detect antibiotics in both freshwater and seawater. Method detection limits for the direct injection technique (37pg/L to 226ng/L in freshwater, and from 16pg/to 26ng/L in seawater) are sufficient for a number of environmental applications, for example the fast screening of water samples for ecological risk assessments. In the present study of real samples, this new method allowed for example the positive detection of some compounds (e.g. lincomycin) down to the sub ng/L range. The direct injection method appears to be relatively cheaper and faster

  12. High-Throughput Fabrication of Nanocone Substrates through Polymer Injection Moulding For SERS Analysis in Microfluidic Systems

    DEFF Research Database (Denmark)

    Viehrig, Marlitt; Matteucci, Marco; Thilsted, Anil H.

    analysis. Metal-capped silicon nanopillars, fabricated through a maskless ion etch, are state-of-the-art for on-chip SERS substrates. A dense cluster of high aspect ratio polymer nanocones was achieved by using high-throughput polymer injection moulding over a large area replicating a silicon nanopillar...... structure. Gold-capped polymer nanocones display similar SERS sensitivity as silicon nanopillars, while being easily integrable into a microfluidic chips....

  13. A detailed cost analysis of in vitro fertilization and intracytoplasmic sperm injection treatment.

    NARCIS (Netherlands)

    Bouwmans, C.A.; Lintsen, A.M.E.; Eijkemans, M.J.; Habbema, J.D.F.; Braat, D.D.M.; Hakkaart, L.

    2008-01-01

    OBJECTIVE: To provide detailed information about costs of in vitro fertilization (IVF) and intracytoplasmic sperm injection (ICSI) treatment stages and to estimate the cost per IVF and ICSI treatment cycle and ongoing pregnancy. DESIGN: Descriptive micro-costing study. SETTING: Four Dutch IVF

  14. Diesel Engine with Different Kind of Injection Systems Exhaust Gas Analysis

    OpenAIRE

    Mantas Smolnikovas; Gintas Viselga; Greta Viselgaitė; Algirdas Jasinskas

    2016-01-01

    The article presents an overview of structural evolution of diesel engines’ injection systems, air pollution caused by diesel engines and permissible emission rates. An analytical research on air pollution was also performed. Experimental studies evaluated air pollution during the emission of particulate matter according to diesel engine exploitation time and different constructions emissions.

  15. Capillary gas chromatographic analysis of nerve agents using large volume injections

    NARCIS (Netherlands)

    Degenhardt, C.E.A.M.; Kientz, C.E.

    1996-01-01

    The use of large volume injections has been studied for the verification of intact organophosphorus chemical warfare agents in water samples. As the use of ethyl acetate caused severe detection problems new potential solvents were evaluated. With the developed procedure, the nerve agents sarin,

  16. Diesel Engine with Different Kind of Injection Systems Exhaust Gas Analysis

    Directory of Open Access Journals (Sweden)

    Mantas Smolnikovas

    2016-02-01

    Full Text Available The article presents an overview of structural evolution of diesel engines’ injection systems, air pollution caused by diesel engines and permissible emission rates. An analytical research on air pollution was also performed. Experimental studies evaluated air pollution during the emission of particulate matter according to diesel engine exploitation time and different constructions emissions.

  17. Statistical Analysis of Interchange Injection Events from Over a Decade of Cassini Data

    Science.gov (United States)

    Azari, A.; Jia, X.; Liemohn, M. W.; Sergis, N.; Thomsen, M. F.; Mitchell, D. G.; Rymer, A. M.; Paranicas, C.; Provan, G.; Ye, S.; Cowley, S. W. H.; Hospodarsky, G. B.; Vandegriff, J. D.; Kurth, W. S.

    2017-12-01

    The Cassini spacecraft has routinely observed interchange injection events with multiple instruments since arriving at Saturn in 2004. Interchange injection events are thought to initiate from a Rayleigh-Taylor like plasma instability sourced from Saturn's rapid rotation (period 10.8 hours) and dense plasma population outgassing primarily from Enceladus, and are the primary source of mass transport in the inner/middle magnetosphere. This dense plasma must be transported outward, and to conserve magnetic flux, inward moving flux tubes of low density, energetic (> keV) plasma from the outer reaches of the Saturnian system also occur. These inward-bound flux tubes are referred to as interchange injections. We will present a statistical evaluation of the occurrence rates of interchange injections at Saturn demonstrating seasonal dependence of interchange over the entirety of the Cassini mission's equatorial orbits between 2005 and 2016. We identify interchange events from CHarge Energy Mass Spectrometer (CHEMS) H+ data using a trained and tested automated algorithm. Our event identification compares well with manual identification and previous surveys of injections by L-shell and local time (Chen and Hill, 2008, Lai et al., 2016, Kennelly et al., 2013). We find that peak rates of interchange events occur between 7 - 9 Saturn radii, in agreement with previous surveys. We also evaluate interchange by preferred local time sector and season, splitting our events into pre-equinox, equinox, and post - equinox time periods. We determine that over all seasons, nightside occurrence dominated as compared to dayside, but the preferred dayside sector shifts from pre-noon during equinox, to post-noon during post-equinox. We will further investigate seasonal dependence by presenting occurrence organized by the phase systems derived based on Saturn kilometric radiation (SKR) and magnetic field perturbations (PPO).

  18. Thermal analysis of injection beam dump of high-intensity rapid-cycling synchrotron in J-PARC

    Science.gov (United States)

    Kamiya, J.; Saha, P. K.; Yamamoto, K.; Kinsho, M.; Nihei, T.

    2017-10-01

    The beam dump at the beam injection area in the J-PARC 3-GeV rapid cycling synchrotron (RCS) accepts beams that pass through the charge exchange foil without ideal electron stripping during the multi-turn beam injection. The injection beam dump consists of the beam pipe, beam stopper, radiation shield, and cooling mechanism. The ideal beam power into the injection beam dump is 400 W in the case of design RCS extraction beam power of 1 MW with a healthy foil, which has 99.7 % charge stripping efficiency. On the other hand, as a radiation generator, the RCS is permitted to be operated with maximum average beam power of 4 kW into the injection beam dump based on the radiation shielding calculation, in consideration of lower charge stripping efficiency due to the foil deterioration. In this research, to evaluate the health of the RCS injection beam dump system from the perspective of the heat generation, a thermal analysis was performed based on the actual configuration with sufficiently large region, including the surrounding concrete and soil. The calculated temperature and heat flux density distribution showed the validity of the mesh spacing and model range. The calculation result showed that the dumped 4 kW beam causes the temperature to increase up to 330, 400, and 140 °C at the beam pipe, beam stopper, and radiation shield, respectively. Although these high temperatures induce stress in the constituent materials, the calculated stress values were lower than the ultimate tensile strength of each material. Transient temperature analysis of the beam stopper, which simulated the sudden break of the charge stripper foil, demonstrated that one bunched beam pulse with the maximum beam power does not lead to a serious rise in the temperature of the beam stopper. Furthermore, from the measured outgassing rate of stainless steel at high temperature, the rise in beam line pressure due to additive outgassing from the heated beam pipe was estimated to have a negligible

  19. Granisetron Injection

    Science.gov (United States)

    Granisetron immediate-release injection is used to prevent nausea and vomiting caused by cancer chemotherapy and to ... nausea and vomiting that may occur after surgery. Granisetron extended-release (long-acting) injection is used with ...

  20. Edaravone Injection

    Science.gov (United States)

    Edaravone injection is used to treat amyotrophic lateral sclerosis (ALS, Lou Gehrig's disease; a condition in which ... die, causing the muscles to shrink and weaken). Edaravone injection is in a class of medications called ...

  1. Meropenem Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria that cause infection.Antibiotics such as meropenem injection will not work for colds, flu, or other viral infections. Taking ...

  2. Chloramphenicol Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by stopping the growth of bacteria..Antibiotics such as chloramphenicol injection will not work for colds, flu, or other viral infections. Taking ...

  3. Colistimethate Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria.Antibiotics such as colistimethate injection will not work for colds, flu, or other viral infections. Using ...

  4. Defibrotide Injection

    Science.gov (United States)

    Defibrotide injection is used to treat adults and children with hepatic veno-occlusive disease (VOD; blocked blood ... the body and then returned to the body). Defibrotide injection is in a class of medications called ...

  5. Nalbuphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using nalbuphine injection, you may experience withdrawal symptoms including restlessness; teary eyes; runny nose; yawning; ...

  6. Home-Made Micro Valve for Determining Malachite Green Dye by Flow Injection Analysis

    Directory of Open Access Journals (Sweden)

    Amal Saadoon Majeed

    2017-07-01

    Full Text Available The research is included studying and designing micro flow injection system which is characterized with rapidity, simplicity, and low cost for the determination of green malachite dye. The study of flow rate of carrier stream, repeatability, dispersion coefficient, and calibration graph are conducted. It is found that the optimum conditions for the determination of mentioned dye are flow rate 4.200 mL/min, sampling rate 102 sample/h, limit of detection 0.05 ppm, linear range (0.05-18.00 ppm with linearity (R2=0.9700, RSD is 0.355, the repeatability for seven successive injections is studied for the two concentrations 5 ppm and 12 ppm, and the dispersion coefficient values are 1.73 and 1.28 at the two concentrations 2 ppm and 9 ppm respectively.

  7. Rheological and thermal analysis of the filling stage of injection moulding

    Directory of Open Access Journals (Sweden)

    A. Szucs

    2012-08-01

    Full Text Available Flow conditions are different in the cavity of the injection mould from the capillary flow of a laboratory rheological instrument. An injection moulding slit die rheometer (Rheo-mould was designed with a series of slit and orifice dies. Four pressure sensors were built in the stationary side of the mould, therefore the pressure could be measured at four different places. A changeable slit die insert was designed in the moving side. The shear stress and the shear rate can be calculated from the pressure gradient and from the flow rate of the melt, respectively. Flow curves of low density polyethylene were determined using Bagley, Rabinowitsch and Mooney corrections. The results were compared to the flow curves determined by Göttfert and Haake capillary equipments. It was found that the agreement between the methods is excellent.

  8. Attack methodology Analysis: SQL Injection Attacks and Their Applicability to Control Systems

    Energy Technology Data Exchange (ETDEWEB)

    Bri Rolston

    2005-09-01

    Database applications have become a core component in control systems and their associated record keeping utilities. Traditional security models attempt to secure systems by isolating core software components and concentrating security efforts against threats specific to those computers or software components. Database security within control systems follows these models by using generally independent systems that rely on one another for proper functionality. The high level of reliance between the two systems creates an expanded threat surface. To understand the scope of a threat surface, all segments of the control system, with an emphasis on entry points, must be examined. The communication link between data and decision layers is the primary attack surface for SQL injection. This paper facilitates understanding what SQL injection is and why it is a significant threat to control system environments.

  9. Analysis of Fuel Injection and Atomization of a Hybrid Air-Blast Atomizer.

    Science.gov (United States)

    Ma, Peter; Esclape, Lucas; Buschhagen, Timo; Naik, Sameer; Gore, Jay; Lucht, Robert; Ihme, Matthias

    2015-11-01

    Fuel injection and atomization are of direct importance to the design of injector systems in aviation gas turbine engines. Primary and secondary breakup processes have significant influence on the drop-size distribution, fuel deposition, and flame stabilization, thereby directly affecting fuel conversion, combustion stability, and emission formation. The lack of predictive modeling capabilities for the reliable characterization of primary and secondary breakup mechanisms is still one of the main issues in improving injector systems. In this study, an unstructured Volume-of-Fluid method was used in conjunction with a Lagrangian-spray framework to conduct high-fidelity simulations of the breakup and atomization processes in a realistic gas turbine hybrid air blast atomizer. Results for injection with JP-8 aviation fuel are presented and compared to available experimental data. Financial support through the FAA National Jet Fuel Combustion Program is gratefully acknowledged.

  10. PTV analysis of the entrained air into the diesel spray at high-pressure injection

    Science.gov (United States)

    Toda, Naoki; Yamashita, Hayato; Mashida, Makoto

    2014-08-01

    In order to clarify the effect of high-pressure injection on soot reduction in terms of the air entrainment into spray, the air flow surrounding the spray and set-off length indicating the distance from the nozzle tip to the flame region in diffusion diesel combustion were investigated using 300MPa injection of a multi-hole injector. The measurement of the air entrainment flow was carried out at non-evaporating condition using consecutive PTV (particle tracking velocimetry) method with a high-speed camera and a high-frequency pulse YAG laser. The set-off length was measured at highpressure and high-temperature using the combustion bomb of constant volume and optical system of shadow graph method. And the amount of air entrainment into spray until reaching set-off length in diffusion combustion was studied as a factor of soot formation.

  11. Flow injection gas chromatography with sulfur chemiluminescence detection for the analysis of total sulfur in complex hydrocarbon matrixes.

    Science.gov (United States)

    Hua, Yujuan; Hawryluk, Myron; Gras, Ronda; Shearer, Randall; Luong, Jim

    2018-01-01

    A fast and reliable analytical technique for the determination of total sulfur levels in complex hydrocarbon matrices is introduced. The method employed flow injection technique using a gas chromatograph as a sample introduction device and a gas phase dual-plasma sulfur chemiluminescence detector for sulfur quantification. Using the technique described, total sulfur measurement in challenging hydrocarbon matrices can be achieved in less than 10 s with sample-to-sample time ideal for fast analysis or trace sulfur analysis. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Stability Analysis of High-Speed Boundary-Layer Flow with Gas Injection

    Science.gov (United States)

    2014-06-01

    laminar-turbulent transition on slender bodies in a hypersonic flow at small angles of attack is caused by amplification of acoustic waves trapped in...x decreases and slowly approaches the no-blow distribution. These CFD data demonstrate that the injection strongly affects the near-wall flow...conclusion. Figure 10 shows that the spatial growth rates ( )  are maximal for mode 0 corresponding to the Mack second mode – typical for hypersonic

  13. Comparative analysis of different process simulation settings of a micro injection molded part featuring conformal cooling

    DEFF Research Database (Denmark)

    Marhöfer, David Maximilian; Tosello, Guido; Islam, Aminul

    2015-01-01

    . In the reported work, process simulations using Autodesk Moldflow Insight 2015® are applied to a micro mechanical part to be fabricated by micro injection molding and with over-all dimensions of 12.0 × 3.0 × 0.8 mm³ and micro features (micro hole, diameter of 580 μm, and sharp radii down to 100 μm). Three...

  14. Estimation of operational parameters for a direct injection turbocharged spark ignition engine by using regression analysis and artificial neural network

    Directory of Open Access Journals (Sweden)

    Tosun Erdi

    2017-01-01

    Full Text Available This study was aimed at estimating the variation of several engine control parameters within the rotational speed-load map, using regression analysis and artificial neural network techniques. Duration of injection, specific fuel consumption, exhaust gas at turbine inlet, and within the catalytic converter brick were chosen as the output parameters for the models, while engine speed and brake mean effective pressure were selected as independent variables for prediction. Measurements were performed on a turbocharged direct injection spark ignition engine fueled with gasoline. A three-layer feed-forward structure and back-propagation algorithm was used for training the artificial neural network. It was concluded that this technique is capable of predicting engine parameters with better accuracy than linear and non-linear regression techniques.

  15. Reliability Analysis of Single-Phase PV Inverters with Reactive Power Injection at Night Considering Mission Profiles

    DEFF Research Database (Denmark)

    Anurag, Anup; Yang, Yongheng; Blaabjerg, Frede

    2015-01-01

    loading, considering the operation outside active feed-in hours. An analytical lifetime model is then employed for lifetime quantization based on the Palgrem Miner rule. Thereafter, considering the lifetime reduction of the PV inverter under different mission profiles with reactive power injection......The widespread adoption of mixed renewables urgently require reactive power exchange at various feed-in points of the utility grid. Photovoltaic (PV) inverters are able to provide reactive power in a decentralized manner at the grid-connection points even outside active power feed-in operation......, especially at night when there is no solar irradiance. This serves as a motivation for utilizing the PV inverters at night for reactive power compensation. Thus, an analysis on the impact of reactive power injection by PV inverters outside feed-in operation on the thermal performance and the reliability has...

  16. Clinical analysis on Shengmai Injection in treating radiation pneumonia and pulmonary fibrosis

    International Nuclear Information System (INIS)

    Yao Chunxiao

    2004-01-01

    Objective: To study the effect of Shengmai Injection in treating radiation pneumonia and pulmonary fibrosis in the course of radiotherapy. Methods: Altogether 96 cases were randomly and equally allocated into a treatment group and a control group, 48 cases each, All patients were treated with radical radiotherapy. The initial radiotherapy was using 10 MV X-rays at conventionally fractionated dose of 60-70 Gy. Patients of the control group were given conventional radiotherapy, and those of the treatment group were given both conventional radiotherapy and Shengmai Injection 40-60 ml by iv drip for 3-5 courses, 10 days for each course. Results: In the treatment group, the incidences of radiation pneumonia and pulmonary fibrosis were 18.8%, 16.7%, respectively, whereas in the control group they were 37.5% and 35.4%, respectively. There were significant differences between the two groups (P<0.05). Conclusion: Shengmai Injection can decrease the incidences of radiation pneumonia and pulmonary fibrosis

  17. Analysis of neutronics and dynamic characteristics with reactivity injection in LBE cooled sub-critical reactor

    International Nuclear Information System (INIS)

    Chen Sen; Wu Yican; Jin Ming; Chen Zhibin; Bai Yunqing; Zhao Zhumin

    2014-01-01

    Accelerator Driven Sub-critical System (ADS) has particular neutronics behaviors compared with the critical system. Prompt jump approximation point reactor kinetics equations taken external source into account have been deduced using an approach of prompt jump approximation. And the relationship between injection reactivity and power ampliation has been achieved. In addition, based on the RELAP5 code the prolong development of point reactor kinetics code used into assessing sub-critical system have been promoted. Different sub-criticality (k eff = 0.90, 0.95, 0.97, 0.98 and 0.99) have been assessed in preliminary design of a type of natural circulation cooling sub-critical reactor under conditions of reactivity injection +1 β in one second. It shows that the external source prompt transient approximation method has an accurate solution after injecting reactivity around short time and has a capacity to solve the dynamic equation, and the sub-critical system has an inner stability while the deeper sub-criticality the less impact on the sub-critical system. (authors)

  18. Pathway analysis of systemic transcriptome responses to injected polystyrene particles in zebrafish larvae.

    Science.gov (United States)

    Veneman, Wouter J; Spaink, Herman P; Brun, Nadja R; Bosker, Thijs; Vijver, Martina G

    2017-09-01

    Microplastics are a contaminant of emergent concern in the environment, however, to date there is a limited understanding on their movement within organisms and the response of organisms. In the current study zebrafish embryos at different development stages were exposed to 700nm fluorescent polystyrene (PS) particles and the response pathway after exposure was investigated using imaging and transcriptomics. Our results show limited spreading of particles within the larvae after injection during the blastula stage. This is in contrast to injection of PS particles in the yolk of 2-day old embryos, which resulted in redistribution of the PS particles throughout the bloodstream, and accumulation in the heart region. Although injection was local, the transcriptome profiling showed strong responses of zebrafish embryos exposed to PS particle, indicating a systemic response. We found several biological pathways activated which are related to an immune response in the PS exposed zebrafish larvae. Most notably the complement system was enriched as indicated by upregulation of genes in the alternative complement pathway (e.g. cfhl3, cfhl4, cfb and c9). The fact that complement pathway is activated indicates that plastic microparticles are integrated in immunological recognition processes. This was supported by fluorescence microscopy results, in which we observed co-localisation of neutrophils and macrophages around the PS particles. Identifying these key events can be a first building block to the development of an adverse outcome pathway (AOP). These data subsequently can be used within ecological and human risk assessment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Design and thermal analysis of a mold used in the injection of elastomers

    Science.gov (United States)

    Fekiri, Nasser; Canto, Cécile; Madec, Yannick; Mousseau, Pierre; Plot, Christophe; Sarda, Alain

    2017-10-01

    In the process of injection molding of elastomers, improving the energy efficiency of the tools is a current challenge for industry in terms of energy consumption, productivity and product quality. In the rubber industry, 20% of the energy consumed by capital goods comes from heating processes; more than 50% of heat losses are linked to insufficient control and thermal insulation of Molds. The design of the tooling evolves in particular towards the reduction of the heated mass and the thermal insulation of the molds. In this paper, we present a complex tool composed, on one hand, of a multi-cavity mold designed by reducing the heated mass and equipped with independent control zones placed closest to each molding cavity and, on the other hand, of a regulated channel block (RCB) which makes it possible to limit the waste of rubber during the injection. The originality of this tool lies in thermally isolating the regulated channel block from the mold and the cavities between them in order to better control the temperature field in the material which is transformed. We present the design and the instrumentation of the experimental set-up. Experimental measurements allow us to understand the thermal of the tool and to show the thermal heterogeneities on the surface of the mold and in the various cavities. Tests of injection molding of the rubber and a thermal balance on the energy consumption of the tool are carried out.

  20. Development and validation of a model for CANDU-6 SDS2 poison injection analysis

    International Nuclear Information System (INIS)

    Lee, B. W.; Jung, C. J.; Min, B. J.; Yoon, H. J.; Choi, J. H.; Jang, D. S.

    2002-01-01

    In CANDU-6 reactor there are two independent reactor shutdown systems. The shutdown system no. 2(SDS2) injects the liquid poison into the moderator tank by high pressure via small holes on the 6 nozzle pipes and stops the nuclear chain reaction. To ensure the safe shutdown of a reactor loaded with either DUPIC or SEU fuels it is necessary for the poison curtains generated by jets provide quick, and enough negative reactivity to the reactor during the early stage of the accident. In order to produce the neutron cross section necessary to perform this work, the poison concentration distribution during the transient is necessary. The motivation for this work arose from the fact that the computer code package for performing this task is not transfered to Korea yet. In this study, a set of models for analyzing the transient poison concentration induced by this high pressure poison injection jet activated upon the reactor trip in a CANDU-6 reactor moderator tank has been developed and used to generate the poison concentration distribution of the poison curtains induced by the high pressure jets injected into the vacant region between the pressure tube banks. The poison injection rate through the jet holes drilled on the nozzle pipes is obtained by a 1-D transient hydrodynamic code called, ALITRIG, and this injection rate is used to provide the inlet boundary condition to a 3-D CFD model of the moderator tank based on CFX4.3, a commercial CFD code developed by AEA technology, to simulate the formation of the poison jet curtain inside the moderator tank. For the validation, a simulation for a generic CANDU-6 SDS2 design poison jet growth experiment was made to evaluate this model's capability against experiment. As no concentration field was measured and only the growth of the poison jet height was obtained by high speed camera, the validation was limited as such. The result showed that if one assume the jet front corresponds to 200 ppm of the poison the model succeed to

  1. Experiment HFR-B1: A preliminary analysis of the water-vapor injection experiments in capsule 3

    International Nuclear Information System (INIS)

    Myers, B.F.

    1993-01-01

    A preliminary analysis of the response of uranium oxycarbide (UCO) fuel to water vapor addition in capsule 3 of experiment HFR-B1 (HFR-B1/3) has been conducted. The analysis provides an early indication of the behavior of fission gas release under a wider range of water-vapor pressures and of temperatures than heretofore studied. A preliminary analysis of selected aspects of the water-vapor injection tests in capsule 3 of experiment HFR-B1 is presented. The release of fission gas stored in bubbles and the diffusive release of fission-gas atoms are distinguished. The dependence of the release of stored fission gas ( 85m Kr) on water-vapor pressure, P(H 2 O), and temperature were established taking into account the contributing mechanisms of gaseous release, the effect of graphite hydrolysis, and the requirement of consistency with experiment HRB-17 in which similar water-vapor injection tests were conducted. The dependence on P(H 2 O) becomes weaker as temperatures increase above 770 degree C; the activation energy for release of stored-fission gas is 393 kJ/mol. Isorelease curves for the pressure-temperature plane were deduced from a derived functional relation. The stored-fission gas releases as a function of P(H 2 O) at a common temperature for experiments HFR-B1 and HRB-17 differ by a factor of 4; this discrepancy could be attributed to the differences in fission-rate density and neutron flux between the two experiments. Diffusive release of fission gas occurred during and after the release of stored gas. The ratio of diffusive release during water-vapor injection to that prior to injection varied in contrast to the results from HRB-17. The variation was attributed to the practice of injecting water vapor into HFR-B1 before sintering of the fuel, hydrolyzed in the previous test, was completed. The derived activation energy for diffusive release is 23.6 kJ/mol

  2. Experiment HFR-B1: A preliminary analysis of the water-vapor injection experiments in capsule 3

    Energy Technology Data Exchange (ETDEWEB)

    Myers, B.F.

    1993-08-01

    A preliminary analysis of the response of uranium oxycarbide (UCO) fuel to water vapor addition in capsule 3 of experiment HFR-B1 (HFR-B1/3) has been conducted. The analysis provides an early indication of the behavior of fission gas release under a wider range of water-vapor pressures and of temperatures than heretofore studied. A preliminary analysis of selected aspects of the water-vapor injection tests in capsule 3 of experiment HFR-B1 is presented. The release of fission gas stored in bubbles and the diffusive release of fission-gas atoms are distinguished. The dependence of the release of stored fission gas ({sup 85m}Kr) on water-vapor pressure, P(H{sub 2}O), and temperature were established taking into account the contributing mechanisms of gaseous release, the effect of graphite hydrolysis, and the requirement of consistency with experiment HRB-17 in which similar water-vapor injection tests were conducted. The dependence on P(H{sub 2}O) becomes weaker as temperatures increase above 770{degree}C; the activation energy for release of stored-fission gas is 393 kJ/mol. Isorelease curves for the pressure-temperature plane were deduced from a derived functional relation. The stored-fission gas releases as a function of P(H{sub 2}O) at a common temperature for experiments HFR-B1 and HRB-17 differ by a factor of 4; this discrepancy could be attributed to the differences in fission-rate density and neutron flux between the two experiments. Diffusive release of fission gas occurred during and after the release of stored gas. The ratio of diffusive release during water-vapor injection to that prior to injection varied in contrast to the results from HRB-17. The variation was attributed to the practice of injecting water vapor into HFR-B1 before sintering of the fuel, hydrolyzed in the previous test, was completed. The derived activation energy for diffusive release is 23.6 kJ/mol.

  3. On-line dynamic fractionation and automatic determination of inorganic phosphorous in environmental solid substrates exploiting sequential injection microcolumn extraction and flow injection analysi

    DEFF Research Database (Denmark)

    Buanuam, Janya; Miró, Manuel; Hansen, Elo Harald

    2006-01-01

    Sequential injection microcolumn extraction (SI-MCE) based on the implementation of a soil containing microcartridge as external reactor in a sequential injection network is, for the first time, proposed for dynamic fractionation of macronutrients in environmental solids, as exemplified by the pa......Sequential injection microcolumn extraction (SI-MCE) based on the implementation of a soil containing microcartridge as external reactor in a sequential injection network is, for the first time, proposed for dynamic fractionation of macronutrients in environmental solids, as exemplified...... by the partitioning of inorganic phosphorous in agricultural soils. The on-line fractionation method capitalises on the accurate metering and sequential exposure of the various extractants to the solid sample by application of programmable flow as precisely coordinated by a syringe pump. Three different soil phase...... associations for phosphorus, that is, exchangeable, Al- and Fe-bound and Ca-bound fractions, were elucidated by accommodation in the flow manifold of the 3 steps of the Hietjles-Litjkema (HL) scheme involving the use of 1.0 M NH4Cl, 0.1 M NaOH and 0.5 M HCl, respectively, as sequential leaching reagents...

  4. Dual-phase gas-permeation flow-injection thermometric analysis for the determination of carbon dioxide.

    Science.gov (United States)

    Liu, S J; Tubino, M

    1998-11-01

    A flow-injection configuration based on a dual-phase gas-permeation system from a liquid donor to a gas acceptor stream with a thermistor flow-through detector is proposed for the direct analysis of the gas in the acceptor. This system was applied for the determination of carbon dioxide (in the form of carbonate) using the following chemical reaction: CO(2)(g)+2NH(3)(g)+H(2)O(g)=(NH(4))(2)CO(3)(s), with a linear response from 1x10(-3) to 50x10(-3) mol l(-1) of CO(3)(2-). Carbon dioxide was produced in the liquid donor and permeated into the gaseous acceptor stream of air/water vapor. The detection limit is 1x10(-3) mol l(-1) of carbonate, and a sampling frequency of 60 h(-1) is achieved with a relative standard deviation of 4.1% for replicate injections. The dual-phase gas-permeation flow-injection manifold, along with the membrane and phase separations, as well as the chemical reaction, provides enhanced selectivity when compared with the system employing a liquid acceptor stream, as serious interferents in this system, for instance, acetate and formate, among others, do not interfere in the proposed system.

  5. Determination of gallic acid with rhodanine by reverse flow injection analysis using simplex optimization.

    Science.gov (United States)

    Phakthong, Wilaiwan; Liawruangrath, Boonsom; Liawruangrath, Saisunee

    2014-12-01

    A reversed flow injection (rFI) system was designed and constructed for gallic acid determination. Gallic acid was determined based on the formation of chromogen between gallic acid and rhodanine, resulting in a colored product with a λmax at 520 nm. The optimum conditions for determining gallic acid were also investigated. Optimizations of the experimental conditions were carried out based on the so-call univariate method. The conditions obtained were 0.6% (w/v) rhodanine, 70% (v/v) ethanol, 0.9 mol L(-1) NaOH, 2.0 mL min(-1) flow rate, 75 μL injection loop and 600 cm mixing tubing length, respectively. Comparative optimizations of the experimental conditions were also carried out by multivariate or simplex optimization method. The conditions obtained were 1.2% (w/v) rhodanine, 70% (v/v) ethanol, 1.2 mol L(-1) NaOH, flow rate 2.5 mL min(-1), 75 μL injection loop and 600 cm mixing tubing length, respectively. It was found that the optimum conditions obtained by the former optimization method were mostly similar to those obtained by the latter method. The linear relationship between peak height and the concentration of gallic acid was obtained over the range of 0.1-35.0 mg L(-1) with the detection limit 0.081 mg L(-1). The relative standard deviations were found to be in the ranges 0.46-1.96% for 1, 10, 30 mg L(-1) of gallic acid (n=11). The method has the advantages of simplicity extremely high selectivity and high precision. The proposed method was successfully applied to the determination of gallic acid in longan samples without interferent effects from other common phenolic compounds that might be present in the longan samples collected in northern Thailand. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. The data analysis of the single well injection-withdraw tracer experiment using the MACRO II

    International Nuclear Information System (INIS)

    Shirakawa, Toshihiko; Kanazawa, Yasuo; Hatanaka, Koichiro

    2001-04-01

    On understanding the radionuclide transport in natural barrier in radioactive waste isolation research, the macroscopic dispersion in heterogeneous permeability field in the underground rock is regarded as an important process. Therefore, we have conducted lots of tracer experiments by the MACRO II facility with an artificially constructed heterogeneous permeability field. In order to study the scale dependence of dispersion coefficients in case of laboratory experiments, we placed the flow cell horizontally, and conducted injection-withdraw tracer experiment with a single well. We have conducted 15 cases experiments. These cases were prepared by changing a position of single well and the injection-withdraw time. At each position we have conducted 9 cases and 6 cases experiments. In this report, we evaluated the macroscopic dispersion coefficients by the fitting of analytical solution to breakthrough curve measured by the 15 cases pumping tracer experiment. Consequently, we could evaluate the dispersion coefficients for 12 cases of 15 cases. Then, we discussed the relation between a injection-withdraw flow rate and a property of heterogeneous media and dispersion coefficient. The conclusions obtained from the results of the evaluation are summarized as follows, It was found that the macroscopic dispersion coefficients tend to be increased with increase of the average radius of tracer front spread around a single well. We have conducted any experiments with s single well settled at two positions. In case of that there is low permeability around a single well, we found dispersion coefficients are large. In case of that there is high permeability around a single well, we found dispersion coefficients are small. In three cases that we could not evaluate because of incorrect accuracy of fitting, we have found it possible that there is some points that dispersion coefficients were strikingly small in tracer front. (author)

  7. Testing gravitational-wave searches with numerical relativity waveforms: results from the first Numerical INJection Analysis (NINJA) project

    International Nuclear Information System (INIS)

    Aylott, Benjamin; Baker, John G; Camp, Jordan; Centrella, Joan; Boggs, William D; Buonanno, Alessandra; Boyle, Michael; Buchman, Luisa T; Chu, Tony; Brady, Patrick R; Brown, Duncan A; Bruegmann, Bernd; Cadonati, Laura; Campanelli, Manuela; Faber, Joshua; Chatterji, Shourov; Christensen, Nelson; Diener, Peter; Dorband, Nils; Etienne, Zachariah B

    2009-01-01

    The Numerical INJection Analysis (NINJA) project is a collaborative effort between members of the numerical relativity and gravitational-wave data analysis communities. The purpose of NINJA is to study the sensitivity of existing gravitational-wave search algorithms using numerically generated waveforms and to foster closer collaboration between the numerical relativity and data analysis communities. We describe the results of the first NINJA analysis which focused on gravitational waveforms from binary black hole coalescence. Ten numerical relativity groups contributed numerical data which were used to generate a set of gravitational-wave signals. These signals were injected into a simulated data set, designed to mimic the response of the initial LIGO and Virgo gravitational-wave detectors. Nine groups analysed this data using search and parameter-estimation pipelines. Matched filter algorithms, un-modelled-burst searches and Bayesian parameter estimation and model-selection algorithms were applied to the data. We report the efficiency of these search methods in detecting the numerical waveforms and measuring their parameters. We describe preliminary comparisons between the different search methods and suggest improvements for future NINJA analyses.

  8. Electrochemical study and flow injection analysis of paracetamol in pharmaceutical formulations based on screen-printed electrodes and carbon nanotubes

    International Nuclear Information System (INIS)

    Fanjul-Bolado, Pablo; Lamas-Ardisana, Pedro Jose; Hernandez-Santos, David; Costa-Garcia, Agustin

    2009-01-01

    Acetaminophenol or paracetamol is one of the most commonly used analgesics in pharmaceutical formulations. Acetaminophen is electroactive and voltammetric mechanistic studies for the electrode processes of the acetaminophenol/N-acetyl-p-quinoneimine redox system are presented. Carbon nanotubes modified screen-printed electrodes with enhanced electron transfer properties are used for the study of the electrochemical-chemical oxidation mechanism of paracetamol at pH 2.0. Quantitative analysis of paracetamol by using its oxidation process (in a Britton-Robinson buffer solution pH 10.0) at +0.20 V (vs. an Ag pseudoreference electrode) on an untreated screen-printed carbon electrode (SPCE) was carried out. Thus, a cyclic voltammetric based reproducible determination of acetaminophen (R.S.D., 2.2%) in the range 2.5 x 10 -6 M to 1 x 10 -3 M, was obtained. However, when SPCEs are used as amperometric detectors coupled to a flow injection analysis (FIA) system, the detection limit achieved for paracetamol was 1 x 10 -7 M, one order of magnitude lower than that obtained by voltammetric analysis. The repeatability of the amperometric detection with the same SPCE is 2% for 15 successive injections of 10 -5 M acetaminophen and do not present any memory effect. Finally, the applicability of using screen-printed carbon electrodes for the electrochemical detection of paracetamol (i.e. for quality control analysis) was demonstrated by using two commercial pharmaceutical products.

  9. Electrochemical study and flow injection analysis of paracetamol in pharmaceutical formulations based on screen-printed electrodes and carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Fanjul-Bolado, Pablo [DropSens, S.L., Edificio Severo Ochoa, Campus El Cristo, 33006 Oviedo, Asturias (Spain); Lamas-Ardisana, Pedro Jose [Departamento de Quimica Fisica y Analitica, Universidad de Oviedo, Julian Claveria 8, 33006 Oviedo, Asturias (Spain); Hernandez-Santos, David [DropSens, S.L., Edificio Severo Ochoa, Campus El Cristo, 33006 Oviedo, Asturias (Spain); Costa-Garcia, Agustin, E-mail: costa@fq.uniovi.es [Departamento de Quimica Fisica y Analitica, Universidad de Oviedo, Julian Claveria 8, 33006 Oviedo, Asturias (Spain)

    2009-04-13

    Acetaminophenol or paracetamol is one of the most commonly used analgesics in pharmaceutical formulations. Acetaminophen is electroactive and voltammetric mechanistic studies for the electrode processes of the acetaminophenol/N-acetyl-p-quinoneimine redox system are presented. Carbon nanotubes modified screen-printed electrodes with enhanced electron transfer properties are used for the study of the electrochemical-chemical oxidation mechanism of paracetamol at pH 2.0. Quantitative analysis of paracetamol by using its oxidation process (in a Britton-Robinson buffer solution pH 10.0) at +0.20 V (vs. an Ag pseudoreference electrode) on an untreated screen-printed carbon electrode (SPCE) was carried out. Thus, a cyclic voltammetric based reproducible determination of acetaminophen (R.S.D., 2.2%) in the range 2.5 x 10{sup -6} M to 1 x 10{sup -3} M, was obtained. However, when SPCEs are used as amperometric detectors coupled to a flow injection analysis (FIA) system, the detection limit achieved for paracetamol was 1 x 10{sup -7} M, one order of magnitude lower than that obtained by voltammetric analysis. The repeatability of the amperometric detection with the same SPCE is 2% for 15 successive injections of 10{sup -5} M acetaminophen and do not present any memory effect. Finally, the applicability of using screen-printed carbon electrodes for the electrochemical detection of paracetamol (i.e. for quality control analysis) was demonstrated by using two commercial pharmaceutical products.

  10. Nanodiamond-based injectable hydrogel for sustained growth factor release: Preparation, characterization and in vitro analysis.

    Science.gov (United States)

    Pacelli, Settimio; Acosta, Francisca; Chakravarti, Aparna R; Samanta, Saheli G; Whitlow, Jonathan; Modaresi, Saman; Ahmed, Rafeeq P H; Rajasingh, Johnson; Paul, Arghya

    2017-08-01

    Nanodiamonds (NDs) represent an emerging class of carbon nanomaterials that possess favorable physical and chemical properties to be used as multifunctional carriers for a variety of bioactive molecules. Here we report the synthesis and characterization of a new injectable ND-based nanocomposite hydrogel which facilitates a controlled release of therapeutic molecules for regenerative applications. In particular, we have formulated a thermosensitive hydrogel using gelatin, chitosan and NDs that provides a sustained release of exogenous human vascular endothelial growth factor (VEGF) for wound healing applications. Addition of NDs improved the mechanical properties of the injectable hydrogels without affecting its thermosensitive gelation properties. Biocompatibility of the generated hydrogel was verified by in vitro assessment of apoptotic gene expressions and anti-inflammatory interleukin productions. NDs were complexed with VEGF and the inclusion of this complex in the hydrogel network enabled the sustained release of the angiogenic growth factor. These results suggest for the first time that NDs can be used to formulate a biocompatible, thermosensitive and multifunctional hydrogel platform that can function both as a filling agent to modulate hydrogel properties, as well as a delivery platform for the controlled release of bioactive molecules and growth factors. One of the major drawbacks associated with the use of conventional hydrogels as carriers of growth factors is their inability to control the release kinetics of the loaded molecules. In fact, in most cases, a burst release is inevitable leading to diminished therapeutic effects and unsuccessful therapies. As a potential solution to this issue, we hereby propose a strategy of incorporating ND complexes within an injectable hydrogel matrix. The functional groups on the surface of the NDs can establish interactions with the model growth factor VEGF and promote a prolonged release from the polymer network

  11. A novel current injection model of PWMSC for control and analysis of power system stability

    Directory of Open Access Journals (Sweden)

    Safari Amin

    2013-01-01

    Full Text Available This paper proposes a novel current injection model of Pulse width Modulation based Series Compensator (PWMSC, as new FACTS controller, for damping of low frequency oscillations. The PWMSC operates as a means of continuous control of the degree of series compensation through the variation of the duty cycle of a train of fixed frequency-pulses. The methodology is tested on the sample single machine power system including PWMSC controller by performing computer simulations for small and large distributions. MATLAB/ Simulink software package was used for the simulations.

  12. The determination of uranium(VI) by flow-injection analysis

    International Nuclear Information System (INIS)

    Jones, E.A.

    1985-01-01

    A method is described for the direct determination of uranium(VI) in waste waters and acid leach liquors by use of a flow-injection procedure and spectrophotometric measurement with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (bromo-PADAP). The interference effects of several commonly occurring elements were studied. The calibration curve is linear over concentrations of uranium(VI) from 0,5 to 20 mg/1, and the precision obtained on a synthetic leach liquor was 0,019 (relative standard deviation). The procedure is rapid and convenient, and up to 40 samples can be analysed in an hour

  13. Analysis of clinical records of dental patients attending Jordan University Hospital: Documentation of drug prescriptions and local anesthetic injections

    Directory of Open Access Journals (Sweden)

    Najla Dar-Odeh

    2008-08-01

    Full Text Available Najla Dar-Odeh1, Soukaina Ryalat1, Mohammad Shayyab1, Osama Abu-Hammad21Department of Oral and Maxillofacial Surgery Oral Medicine and Periodontics, Faculty of Dentistry, University of Jordan, Jordan; 2Department of Prosthetic Dentistry, Faculty of Dentistry, University of Jordan, JordanObjectives: The aim of this study was to analyze clinical records of dental patients attending the Dental Department at the University of Jordan Hospital: a teaching hospital in Jordan. Analysis aimed at determining whether dental specialists properly documented the drug prescriptions and local anesthetic injections given to their patients.Methods: Dental records of the Dental Department at the Jordan University Hospital were reviewed during the period from April 3rd until April 26th 2007 along with the issued prescriptions during that period.Results: A total of 1000 records were reviewed with a total of 53 prescriptions issued during that period. Thirty records documented the prescription by stating the category of the prescribed drug. Only 13 records stated the generic or the trade names of the prescribed drugs. Of these, 5 records contained the full elements of a prescription. As for local anesthetic injections, the term “LA used” was found in 22 records while the names and quantities of the local anesthetics used were documented in only 13 records. Only 5 records documented the full elements of a local anesthetic injection.Conclusion: The essential data of drug prescriptions and local anesthetic injections were poorly documented by the investigated group of dental specialists. It is recommended that the administration of the hospital and the dental department implement clear and firm guidelines for dental practitioners in particular to do the required documentation procedure.Keywords: dental records, documentation, prescriptions, local anesthesia

  14. Radiologic Analysis and Clinical Study of the Upper One-third Joint Technique for Fluoroscopically Guided Sacroiliac Joint Injection.

    Science.gov (United States)

    Park, Junghyun; Park, Hue Jung; Moon, Dong Eon; Sa, Gye Jeol; Kim, Young Hoon

    2015-01-01

    Sacroiliac intraarticular injection by the traditional technique can be challenging to perform when the joint is covered with osteophytes or is extremely narrow. To examine whether there is enough space for the needle to be advanced from the L5-S1 interspinous space to the upper one-third sacroiliac joint (SIJ) by magnetic resonance image (MRI) analysis as an alternative to fluoroscopically guided SIJ injection with the lower one-third joint technique, and to determine the feasibility of this novel technique in clinical practice. MRI analysis and observational study. An interventional pain management practice at a university hospital. We analyzed 200 axial T2-weighted MRIs between the L5 and S1 vertebrae of 100 consecutive patients. The following measurements were obtained on both sides: 1) the thickness of fat in the midline; 2) the distance between the midline (Point C) and the junction (Point A) of the skin and the imaginary line that connects the SIJ and the most medial cortex of the ilium; 3) the distance between the midline (Point C) and the junction (Point B) of the skin and the imaginary line that connects the SIJ and the L5 spinous process; 4) the distance between the SIJ and midline (Point C) on the skin, or between the SIJ and the midpoint (Point C') of the line from Point A to Point B; and 5) the angle between the sagittal line and the imaginary line that connects the SIJ and the midline on the skin. The upper one-third joint technique was performed to establish the feasibility of the alternative technique in 20 patients who had unsuccessful sacroiliac intraarticular injections using the lower one-third joint technique. The mean distances from the midline to Point A and to Point B were 21.9 ± 13.7 mm and 27.8 ± 13.6 mm, respectively. The mean distance between the SIJ and Point C (or Point C') was 81.0 ± 13.3 mm. The angle between the sagittal line and the imaginary line that connects the SIJ and the midline on the skin was 42.8 ± 5.1°. The success

  15. Influences of diesel pilot injection on ethanol autoignition - a numerical analysis

    Science.gov (United States)

    Burnete, N. V.; Burnete, N.; Jurchis, B.; Iclodean, C.

    2017-10-01

    The aim of this study is to highlight the influences of the diesel pilot quantity as well as the timing on the autoignition of ethanol and the pollutant emissions resulting from the combustion process. The combustion concept presented in this paper requires the injection of a small quantity of diesel fuel in order to create the required autoignition conditions for ethanol. The combustion of the diesel droplets injected in the combustion chamber lead to the creation of high temperature locations that favour the autoignition of ethanol. However, due to the high vaporization enthalpy and the better distribution inside the combustion chamber of ethanol, the peak temperature values are reduced. Due to the lower temperature values and the high burning velocity of ethanol (combined with the fact that there are multiple ignition sources) the conditions required for the formation of nitric oxides are not achieved anymore, thus leading to significantly lower NOx emissions. This way the benefits of the Diesel engine and of the constant volume combustion are combined to enable a more efficient and environmentally friendly combustion process.

  16. Asymptotic analysis soot model and experiment for a directed injection engine

    Science.gov (United States)

    Liu, Yongfeng; Pei, Pucheng; Xiong, Qinghui; Lu, Yong

    2012-09-01

    The existing soot models are either too complex and can not be applied to the internal combustion engine, or too simple to make calculation errors. Exploring the soot model becomes the pursuit of the goal of many researchers within the error range in the current computer speed. On the basis of the latest experimental results, TP (temperature phases) model is presented as a new soot model to carry out optimization calculation for a high-pressure common rail diesel engine. Temperature and excess air factor are the most important two parameters in this model. When zone temperature T0.6, only the soot precursors—polycyclic aromatic hydrocarbons(PAH) is created and there is no soot emission. When zone temperature T ⩾ 1 500 K and excess air factor Φinjection time, variation of rail pressure and variation of speed among TP models. The experimental results indicate that the TP model can carry out optimization and computational fluid dynamics can be a tool to calculate for a high-pressure common rail directed injection diesel engine. The TP model result is closer than the use of the original KIVA-3V results of soot model accuracy by about 50% and TP model gives a new method for engine researchers.

  17. A qualitative analysis of methotrexate self-injection education videos on YouTube.

    Science.gov (United States)

    Rittberg, Rebekah; Dissanayake, Tharindri; Katz, Steven J

    2016-05-01

    The aim of this study is to identify and evaluate the quality of videos for patients available on YouTube for learning to self-administer subcutaneous methotrexate. Using the search term "Methotrexate injection," two clinical reviewers analyzed the first 60 videos on YouTube. Source and search rank of video, audience interaction, video duration, and time since video was uploaded on YouTube were recorded. Videos were classified as useful, misleading, or a personal patient view. Videos were rated for reliability, comprehensiveness, and global quality scale (GQS). Reasons for misleading videos were documented, and patient videos were documented as being either positive or negative towards methotrexate (MTX) injection. Fifty-one English videos overlapped between the two geographic locations; 10 videos were classified as useful (19.6 %), 14 misleading (27.5 %), and 27 personal patient view (52.9 %). Total views of videos were 161,028: 19.2 % useful, 72.8 % patient, and 8.0 % misleading. Mean GQS: 4.2 (±1.0) useful, 1.6 (±1.1) misleading, and 2.0 (±0.9) for patient videos (p tool available, clinicians need to be familiar with specific resources to help guide and educate their patients to ensure best outcomes.

  18. Capillary gas chromatographic analysis of nerve agents using large volume injections. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Deinum, T.; Nieuwenhuy, C.

    1994-11-01

    The procedure developed at TNO-Prins Maurits Laboratory (TNO-PML) for the verification of intact organophosphorus chemical warfare agents in water samples was improved. The last step in this procedure, the laborious and non-reproducible transfer of an ethyl acetate extract onto a Tenax-adsorption tube followed by thermal desorption of the Tenax-tube, was replaced by large volume injection of the extract onto a capillary gas chromatographic system. The parameters controlling the injection of a large volume of an extract (200 ul) were investigated and optimized. As ethyl acetate caused severe problems, potential new solvents were evaluated. With the improved procedure, the nerve agents sarin, tabun, soman, diisopropyl fluorophosphate (DFP) and VX could be determined in freshly prepared water samples at pg/ml (ppt) levels. The fate of the nerve agents under study in water at two pH`s (4.8 and 6) was investigated. For VX, the pH should be adjusted before extraction. Moreover, it is worthwhile to acidify water samples to diminish hydrolysis.

  19. Anticipated transient without scram analysis of the simplified boiling water reactor following main steam isolation valve closure with boron injection

    International Nuclear Information System (INIS)

    Khan, H.J.; Cheng, H.S.; Rohatgi, U.S.

    1996-01-01

    The simplified boiling water reactor (SBWR) operating in natural circulation is designed with many passive safety features. An anticipated transient without scram (ATWS) initiated by inadvertent closure of the main steam isolation valve (MSIV) in an SBWR has been analyzed using the RAMONA-4B code of Brookhaven National Laboratory. This analysis demonstrates the predicted performance of the SBWR during an MSIV closure ATWS, followed by shutdown of the reactor through injection of boron into the reactor core from the standby liquid control system

  20. Automation of radiochemical analysis by flow injection techniques. Am-Pu separation using TRU-resinTM sorbent extraction column

    International Nuclear Information System (INIS)

    Egorov, O.; Washington Univ., Seattle, WA; Grate, J.W.; Ruzicka, J.

    1998-01-01

    A rapid automated flow injection analysis (FIA) procedure was developed for efficient separation of Am and Pu from each other and from interfering matrix and radionuclide components using a TRU-resin TM column. Selective Pu elution is enabled via on-column reduction. The separation was developed using on-line radioactivity detection. After the separation had been developed, fraction collection was used to obtain the separated fractions. In this manner, a FIA instrument functions as an automated separation workstation capable of unattended operation. (author)

  1. On-line liquid phase micro-extraction based on drop-in-plug sequential injection lab-at-valve platform for metal determination

    Energy Technology Data Exchange (ETDEWEB)

    Mitani, Constantina [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124 (Greece); Anthemidis, Aristidis N., E-mail: anthemid@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124 (Greece)

    2013-04-10

    Highlights: ► Drop-in-plug micro-extraction based on SI-LAV platform for metal preconcentration. ► Automatic liquid phase micro-extraction coupled with FAAS. ► Organic solvents with density higher than water are used. ► Lead determination in environmental water and urine samples. -- Abstract: A novel automatic on-line liquid phase micro-extraction method based on drop-in-plug sequential injection lab-at-valve (LAV) platform was proposed for metal preconcentration and determination. A flow-through micro-extraction chamber mounted at the selection valve was adopted without the need of sophisticated lab-on-valve components. Coupled to flame atomic absorption spectrometry (FAAS), the potential of this lab-at-valve scheme is demonstrated for trace lead determination in environmental and biological water samples. A hydrophobic complex of lead with ammonium pyrrolidine dithiocarbamate (APDC) was formed on-line and subsequently extracted into an 80 μL plug of chloroform. The extraction procedure was performed by forming micro-droplets of aqueous phase into the plug of the extractant. All critical parameters that affect the efficiency of the system were studied and optimized. The proposed method offered good performance characteristics and high preconcentration ratios. For 10 mL sample consumption an enhancement factor of 125 was obtained. The detection limit was 1.8 μg L{sup −1} and the precision expressed as relative standard deviation (RSD) at 50.0 μg L{sup −1} of lead was 2.9%. The proposed method was evaluated by analyzing certified reference materials and applied for lead determination in natural waters and urine samples.

  2. Analysis of synchronized regimes for injection-locked spin-transfer nano-oscillators

    Energy Technology Data Exchange (ETDEWEB)

    D' Aquino, M., E-mail: daquino@uniparthenope.it [Department of Technology, University of Napoli ' Parthenope' , 80143 Napoli (Italy); Serpico, C. [Department of Engineering, University of Napoli Federico II, 80125 Napoli (Italy); Bonin, R. [Politecnico di Torino - Sede di Verres, 11029 Verres (Aosta) (Italy); Bertotti, G. [Istituto Nazionale di Ricerca Metrologica, 10135 Torino (Italy); Mayergoyz, I.D. [ECE Dept. and UMIACS, University of Maryland, College Park, MD 20742 (United States)

    2012-05-01

    The large-angle magnetization dynamics of an injection-locked spin-transfer nano-oscillator (STNO) is studied. The magnetic system is subject to the action of time-varying spin-polarized currents and external magnetic fields. The uniform mode theory is developed and describes the hysteretic synchronization mechanism in terms of bifurcations of equilibria and limit cycles of appropriate dynamical systems. Analytical predictions of control parameters for the synchronization between the magnetization self-oscillation and the external microwave excitations (current, field) are provided. The effect of temperature on the locking band and the hysteretic character of the oscillation response is analyzed. An analytical approach is developed to determine the thermally induced sidebands in the power spectral density of phase-locked oscillations as a function of control parameters. The analytical predictions are in good agreement with the results of numerical simulations.

  3. Analysis of inadvertent safety injection incident at Kori unit 3 on september 6, 1990

    International Nuclear Information System (INIS)

    Kim, Kyun Tae; Chung, Bub Dong; Kim, In Goo; Kim, Hho Jung

    1992-01-01

    The inadvertent safety injection incident occurred at Kori Unit 3 on September 6, 1990 is analyzed using RELAP5/MOD3 code. The event was initiated by a failure of main feedwater control valve in one of three steam generators. The actual sequence of plant transient with the proper estimations of the operator actions is investigated in the present calculation. The calculational results are compared with the plant transient data. It is shown that the results of the plant behaviors are in good agreement with the plant data. The emergency response guidelines is assessed for the time of the SI termination and the establishment of natural circulation. The changes in the time of the SI termination do not significantly affect the overall plant behaviors, and the natural circulation is established

  4. Determination of uranium in organic phase by flow injection spectrophotometric analysis

    International Nuclear Information System (INIS)

    Yu Yiyun

    1998-01-01

    Based on the use of merging zone circuit and simulating a series of standard solution of uranium in organic phase, uranium in unknown organic phase sample was determined by flow injection spectrophotometry. A linear calibration graph was obtained with correlation coefficient of 0.999 for uranium concentration in organic phase over 10∼200 mg/L. Isopropyl alcohol was used as carrier solution. Mixing colour solution contains isopropyl alcohol, triethanolamine, masking reagent and Br-PADAP. The relative standard deviation of the method was better than +-5%. Determination of each sample can be completed in one minute. The method characteristic is: (1) using merging zone and simulating standard solution of uranium in organic phase, the method is sensitive and reliable; (2) even if the determined solution was in turbid condition, it can be quantitatively determined; (3) by means of solution replace technique, the tube of peristaltic pump can be used over a long period of time

  5. [Incidence rate of adverse reaction/event by Qingkailing injection: a Meta-analysis of single rate].

    Science.gov (United States)

    Ai, Chun-ling; Xie, Yan-ming; Li, Ming-quan; Wang, Lian-xin; Liao, Xing

    2015-12-01

    To systematically review the incidence rate of adverse drug reaction/event by Qingkailing injection. Such databases as the PubMed, EMbase, the Cochrane library, CNKI, VIP WanFang data and CBM were searched by computer from foundation to July 30, 2015. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data and cross check data. Then, Meta-analysis was performed by using the R 3.2.0 software, subgroup sensitivity analysis was performed based on age, mode of medicine, observation time and research quality. Sixty-three studies involving 9,793 patients with Qingkailing injection were included, 367 cases of adverse reactions/events were reported in total. The incidence rate of adverse reaction in skin and mucosa group was 2% [95% CI (0.02; 0.03)]; the digestive system adverse reaction was 6% [95% CI(0.05; 0.07); the injection site adverse reaction was 4% [95% CI (0.02; 0.07)]. In the digestive system as the main types of adverse reactions/events, incidence of children and adults were 4.6% [0.021 1; 0.097 7] and 6.9% [0.053 5; 0.089 8], respectively. Adverse reactions to skin and mucous membrane damage as the main performance/event type, the observation time > 7 days and ≤ 7 days incidence of 3% [0.012 9; 0.068 3] and 1.9% [0.007 8; 0.046 1], respectively. Subgroup analysis showed that different types of adverse reactions, combination in the incidence of adverse reactions/events were higher than that of single drug, the difference was statistically significant (P reactions occur, and clinical rational drug use, such as combination, age and other fators, and the influence factors vary in different populations. Therefore, clinical doctors for children and the elderly use special care was required for a clear and open spirit injection, the implementation of individualized medication.

  6. Transient computational fluid dynamics analysis of emergency core cooling injection at natural circulation conditions

    Energy Technology Data Exchange (ETDEWEB)

    Scheuerer, Martina, E-mail: Martina.Scheuerer@grs.de [Gesellschaft fuer Anlagen- und Reaktorsicherheit, Forschungsinstitute, 85748 Garching (Germany); Weis, Johannes, E-mail: Johannes.Weis@grs.de [Gesellschaft fuer Anlagen- und Reaktorsicherheit, Forschungsinstitute, 85748 Garching (Germany)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer Pressurized thermal shocks are important phenomena for plant life extension and aging. Black-Right-Pointing-Pointer The thermal-hydraulics of PTS have been studied experimentally and numerically. Black-Right-Pointing-Pointer In the Large Scale Test Facility a loss of coolant accident was investigated. Black-Right-Pointing-Pointer CFD software is validated to simulate the buoyancy driven flow after ECC injection. - Abstract: Within the framework of the European Nuclear Reactor Integrated Simulation Project (NURISP), computational fluid dynamics (CFD) software is validated for the simulation of the thermo-hydraulics of pressurized thermal shocks. A proposed validation experiment is the test series performed within the OECD ROSA V project in the Large Scale Test Facility (LSTF). The LSTF is a 1:48 volume-scaled model of a four-loop Westinghouse pressurized water reactor (PWR). ROSA V Test 1-1 investigates temperature stratification under natural circulation conditions. This paper describes calculations which were performed with the ANSYS CFD software for emergency core cooling injection into one loop at single-phase flow conditions. Following the OECD/NEA CFD Best Practice Guidelines (Mahaffy, 2007) the influence of grid resolution, discretisation schemes, and turbulence models (shear stress transport and Reynolds stress model) on the mixing in the cold leg were investigated. A half-model was used for these simulations. The transient calculations were started from a steady-state solution at natural circulation conditions. The final calculations were obtained in a complete model of the downcomer. The results are in good agreement with data.

  7. Qualitative analysis of subcutaneous Lispro and regular insulin injections for stress hyperglycemia: a pilot numerical study.

    Science.gov (United States)

    Strilka, Richard J; Armen, Scott B; Indeck, Matthew C

    2014-09-07

    Increased glucose variability (GV) is an independent risk factor for mortality in the critically ill; unfortunately, the optimal insulin therapy that minimizes GV is not known. We simulate the glucose-insulin feedback system to study how stress hyperglycemia (SH) states, taken to be a non-uniform group of physiologic disorders with varying insulin resistance (IR) and similar levels of hyperglycemia, respond to the type and dose of subcutaneous (SQ) insulin. Two groups of 100 virtual patients are studied: those receiving and those not receiving continuous enteral feeds. Stress hyperglycemia was facilitated by doubling the gluconeogenesis rate and IR was stepwise varied from a borderline to a high value. Lispro and regular insulin were simulated with dosages that ranged from 0 to 6 units; the resulting GV was analyzed after each insulin injection. The numerical model used consists of a set of non-linear differential equations with two time delays and five adjustable parameters. The results show that regular insulin decreased GV in both patient groups and rarely caused hypoglycemia. With continuous enteral feeds and borderline to mild IR, Lispro showed minimal effect on GV; however, rebound hyperglycemia that increased GV occurred when the IR was moderate to high. Without a nutritional source, Lispro worsened GV through frequent hypoglycemia episodes as the injection dose increased. The inferior performance of Lispro is a result of its rapid absorption profile; half of its duration of action is similar to the glucose ultradian period. Clinical trials are needed to examine whether these numerical results represent the glucose-insulin dynamics that occur in intensive care units, and if such dynamics are present, their clinical effects should be evaluated. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. Thermal analysis evaluation of the reactivity of coal mixtures for injection in the blast furnace

    Directory of Open Access Journals (Sweden)

    Maria de Lourdes Ilha Gomes

    2006-03-01

    Full Text Available Pulverized Coal Injection (PCI is an important standard technology replacing coke partially by pulverized coal into the blast furnace that allows a significant reduction of hot metal costs and environmental impact, contributing to a decrease of coke requirements for ironmaking. Coals typically used in this process in Brazil are, at current time, exclusively imported from many countries, although economic important coal-measures occur in the southern part of the country. The Brazilian coals have a low rank, higher contents of inert components, proportioning nocoking properties and an expected high reactivity. Due to these caractheristics, these coals could be used for injection in the blast furnaces in order to decrease the dependency on high cost imported coals. The efficiency in the combustion and the coal reactivity are considered important parameters in the blast furnace, since a larger amount of char (unburned coal causes severe problems to the furnace operation. The aim of the present work is to compare the reactivity of a south Brazilian coal, obtained from Faxinal mine, with two imported coals and the blends of the Brazilian coal with the imported ones. The reactivity of these coals and their blends were evaluated in a thermogravimetric analyzer. In the experiments, various mass ratios of Faxinal coal and the imported coals were used to compose the blends. The gasification reaction with pure CO2 was conducted under isothermal conditions at 1050 °C and atmospheric pressure. The experimental results show the greater reactivity of the Faxinal coal. The additive behavior was confirmed. The blends with a composition of up to 50% Faxinal coal have parameters according to the usual limits used for PCI.

  9. Transient computational fluid dynamics analysis of emergency core cooling injection at natural circulation conditions

    International Nuclear Information System (INIS)

    Scheuerer, Martina; Weis, Johannes

    2012-01-01

    Highlights: ► Pressurized thermal shocks are important phenomena for plant life extension and aging. ► The thermal-hydraulics of PTS have been studied experimentally and numerically. ► In the Large Scale Test Facility a loss of coolant accident was investigated. ► CFD software is validated to simulate the buoyancy driven flow after ECC injection. - Abstract: Within the framework of the European Nuclear Reactor Integrated Simulation Project (NURISP), computational fluid dynamics (CFD) software is validated for the simulation of the thermo-hydraulics of pressurized thermal shocks. A proposed validation experiment is the test series performed within the OECD ROSA V project in the Large Scale Test Facility (LSTF). The LSTF is a 1:48 volume-scaled model of a four-loop Westinghouse pressurized water reactor (PWR). ROSA V Test 1-1 investigates temperature stratification under natural circulation conditions. This paper describes calculations which were performed with the ANSYS CFD software for emergency core cooling injection into one loop at single-phase flow conditions. Following the OECD/NEA CFD Best Practice Guidelines (Mahaffy, 2007) the influence of grid resolution, discretisation schemes, and turbulence models (shear stress transport and Reynolds stress model) on the mixing in the cold leg were investigated. A half-model was used for these simulations. The transient calculations were started from a steady-state solution at natural circulation conditions. The final calculations were obtained in a complete model of the downcomer. The results are in good agreement with data.

  10. Analysis of large break loss of coolant accident with simultaneous injection into cold leg and hot leg

    International Nuclear Information System (INIS)

    Luo Bangqi

    1997-01-01

    When a large break loss of coolant accident occurs, the most part of the safety injection water injected into the cold leg by the safety injection system will flow through the channel between the pressure vessel and the barrel out of the break into the containment, only a little part of the safety injection water can flow into the reactor core. If the safety injection can inject into both the cold leg and the hot leg simultaneously, the safety injection water injected from the cold leg will flow into the core more easily, because the safety injection water injected from the hot leg will carry out more heat from the upper plenum and the core, so the upper plenum and the core is depressed. In addition, a small part of the safety injection water injected from the hot leg will flow down in the core after impinging the guide tubes in the upper plenum, so the core will get more safety injection water than only cold leg injection, and the core will be much safer

  11. Subcutaneous Injections

    DEFF Research Database (Denmark)

    Thomsen, Maria

    This thesis is about visualization and characterization of the tissue-device interaction during subcutaneous injection. The tissue pressure build-up during subcutaneous injections was measured in humans. The insulin pen FlexTouchr (Novo Nordisk A/S) was used for the measurements and the pressure ...

  12. Hydromorphone Injection

    Science.gov (United States)

    ... anyone else to use your medication. Store hydromorphone injection in a safe place so that no one else can use it accidentally or on purpose. Keep track of how much medication is left so ... with hydromorphone injection may increase the risk that you will develop ...

  13. Ketorolac Injection

    Science.gov (United States)

    ... an older adult, you should know that ketorolac injection is not as safe as other medications that can be used to treat your condition. Your doctor may choose to prescribe a different medication ... to ketorolac injection.Your doctor or pharmacist will give you the ...

  14. Paclitaxel Injection

    Science.gov (United States)

    (pak'' li tax' el)Paclitaxel injection must be given in a hospital or medical facility under the supervision of a doctor who is experienced in giving chemotherapy medications for cancer.Paclitaxel injection may cause a large decrease in the number of white blood cells (a type of blood cell ...

  15. Comprehensive analysis of chemical constituents in Xingxiong injection by high performance liquid chromatography coupled with mass spectrometry.

    Science.gov (United States)

    Guo, Long; Dou, Li-Li; Duan, Li; Liu, Ke; Bi, Zhi-Ming; Li, Ping; Liu, E-Hu

    2015-09-01

    Xingxiong injection (XXI) is a widely used Chinese herbal formula prepared by the folium ginkgo extract and ligustrazine for the treatment of cardiovascular and cerebrovascular diseases. Compared with the pharmacological studies, chemical analysis and quality control studies on this formula are relatively limited. In the present study, a high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (HPLC-QTOF MS) method was applied to comprehensive analysis of constituents in XXI. According to the fragmentation rules and previous reports, thirty ginkgo flavonoids, four ginkgo terpene lactones, and one alkaloid were identified. A high performance liquid chromatography coupled with triple quadrupole mass spectrometry (HPLC-QQQ MS) method was then applied to quantify ten major constituents in XXI. The method validation results indicated that the developed method had desirable specificity, linearity, precision and accuracy. The total contents of ginkgo flavonoids were about 22.05-25.51 μg·mL(-1) and the ginkgo terpene lactones amounts were about 4.41-8.70 μg·mL(-1) in six batches of XXI samples, respectively. Furthermore, cosine ratio algorithm and distance measurements were employed to evaluate the similarity of XXI samples, and the results demonstrated a high-quality consistency. This work could provide comprehensive information on the quality control of Xingxiong injection, which be helpful in the establishment of a rational quality control standard. Copyright © 2015 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  16. Ultra trace analysis of PAHs by designing simple injection of large amounts of analytes through the sample reconcentration on SPME fiber after magnetic solid phase extraction.

    Science.gov (United States)

    Khodaee, Nader; Mehdinia, Ali; Esfandiarnejad, Reyhaneh; Jabbari, Ali

    2016-01-15

    A simple solventless injection method was introduced based on the using of a solid-phase microextraction (SPME) fiber for injection of large amounts of the analytes extracted by the magnetic solid phase extraction (MSPE) procedure. The resulted extract from MSPE procedure was loaded on a G-coated SPME fiber, and then the fiber was injected into the gas chromatography (GC) injection port. This method combines the advantages of exhaustive extraction property of MSPE and the solvent-less injection of SPME to improve the sensitivity of the analysis. In addition, the analytes were re-concentrated prior to inject into the gas chromatography (GC) inlet because of the organic solvent removing from the remaining extract of MSPE technique. Injection of the large amounts of analytes was made possible by using the introduced procedure. Fourteen polycyclic aromatic hydrocarbons (PAHs) with different volatility were used as model compounds to investigate the method performance for volatile and semi-volatile compounds. The introduced method resulted in the higher enhancement factors (5097-59376), lower detection limits (0.29-3.3pgmL(-1)), and higher sensitivity for the semi-volatile compounds compared with the conventional direct injection method. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Response of different injector typologies to dwell time variations and a hydraulic analysis of closely-coupled and continuous rate shaping injection schedules

    International Nuclear Information System (INIS)

    Ferrari, A.; Mittica, A.

    2016-01-01

    Highlights: • Direct and indirect acting injectors are tested considering multiple injections. • The injection fusion threshold is higher for ballistic injectors than for stroke-end limited injectors. • The internal dynamics of the injector is analyzed for closely-coupled double injections. • Different regimes are identified and classified in the short dwell time range. • Innovative rate shaping injection schedules are defined for solenoid injectors. - Abstract: The multiple injection performance of Common Rail injectors has been analyzed at a hydraulic test rig as the dwell time was varied. The dependence of the injected volume on the dwell time has been investigated for direct acting piezoelectric and hydraulically-controlled (or indirect-acting) servo injectors. The injected fuel volumes in the long dwell-time range have been shown to be affected by the pressure waves that travel along the high pressure circuit for hydraulically-controlled servo injectors. On the other hand, the influence of pressure-wave-induced disturbances on multiple injection performance has been shown to be negligible for direct acting piezoelectric injectors. An analysis of closely-coupled injections has been conducted on a solenoid injector. When the dwell time is progressively reduced below a critical value, an increase in the fuel quantity that is injected in the second shot is observed. Injection fusion phenomena occur as the dwell time is diminished below a certain threshold and a maximum in the fuel volume, which is injected during the joint injections, is eventually detected for a very short electric dwell time value close to 100 μs. The cycle-to-cycle dispersion around this dwell time value results to be reduced significantly. A previously developed 1D model of the fuel injection system has been applied to analyze the injector transients. Detailed knowledge of the injection dynamics in the short dwell time region is of fundamental importance to optimize the

  18. Observation of curative effect of intravitreal injection of conbercept in wet age-related macular degeneration: Optical coherence tomography analysis after injection.

    Science.gov (United States)

    Yang, Wen; Tan, Ying; Li, Chaowei; Liu, Yi; Lu, Guohua

    2018-04-01

    To observe the clinical efficacy of intravitreal injection of conbercept in the treatment of wet age-related macular degeneration (wAMD), optical coherence tomography (OCT) and the best corrected visual acuity (BCVA) was observed to measure the changes of anatomical changes of central macular thickness (CMT) and the area and volume of retinal pigment epithelium (RPE) uplift. Fifteen patients (15 eyes) with wet AMD were enrolled in this study. All patients underwent intravitreal injection of conbercept of 0.05 mL once. After 1 week, 1 month, and 3 months, OCT and BCVA were used to examine and to compare with the preoperative and postoperative central macular thickness and RPE uplift area. BCVA (median) increased respectively from 0.12 ± 0.13 to 0.21 ± 0.15 at 1 week, to 0.90 ± 0.25 at 1 month, to 0.38 ± 0.17 at 3 months (p macular decreased from 500 ± 25 μm to 256 ± 19 μm, 221 ± 29 μm, and 215 ± 14 μm, respectively. The normal physiological structure and stratification of the macular area were clear gradually. Conbercept treatment of wet AMD can significantly improve visual acuity, after 1 month up to the plateau, 3 months of continuous drug injection can make the vision maintained at a high stage, and macular retinal normal structural morphology recovery is good, the treatment has no obvious adverse reactions, and with good security. © 2018 Wiley Periodicals, Inc.

  19. The determination of levofloxacin by flow injection analysis using UV detection, potentiometry, and conductometry in pharmaceutical preparations.

    Science.gov (United States)

    Altiokka, G; Atkosar, Z; Can, N O

    2002-10-15

    A flow injection analysis (FIA) using UV detection, potentiometry and conductometry for levofloxacin (LVF) are described in this study. The best solvent system was found to consist of 0.2 M acetate buffer at pH 3 having 10% MeOH. A flow rate of 1 ml min(-1) was pumped and active material was detected at 288 nm. The detection limit (LOD) and limit of quantification (LOQ) for FIA were calculated to be 3 x 10(-7) M (S/N = 3) and 1 x 10(-7) M (S/N = 10), respectively. In the analysis of tablets, the RSD values were found to be 0.83, 0.98 and 0.99 for FIA, potentiometric and conductometric methods, respectively. Copyright 2002 Elsevier Science B.V.

  20. NGS combined with phylogenetic analysis to detect HIV-1 dual infection in Romanian people who inject drugs.

    Science.gov (United States)

    Popescu, Bogdan; Banica, Leontina; Nicolae, Ionelia; Radu, Eugen; Niculescu, Iulia; Abagiu, Adrian; Otelea, Dan; Paraschiv, Simona

    2018-04-04

    Dual HIV infections are possible and likely in people who inject drugs (PWID). Thirty-eight newly diagnosed patients, 19 PWID and 19 heterosexually HIV infected were analysed. V2-V3 loop of HIV-1 env gene was sequenced on the NGS platform 454 GSJunior (Roche). HIV-1 dual/multiple infections were identified in five PWID. For three of these patients, the reconstructed variants belonged to pure F1 subtype and CRF14_BG strains according to phylogenetic analysis. New recombinant forms between these parental strains were identified in two PWID samples. NGS data can provide, with the help of phylogenetic analysis, important insights about the intra-host sub-population structure. Copyright © 2018. Published by Elsevier Masson SAS.

  1. Rapid isolation of biomarkers for compound specific radiocarbon dating using high-performance liquid chromatography and flow injection analysis-atmospheric pressure chemical ionisation mass spectrometry

    NARCIS (Netherlands)

    Sinninghe Damsté, J.S.; Smittenberg, R.H.; Hopmans, E.C.; Schouten, S.

    2002-01-01

    Repeated semi-preparative normal-phase HPLC was performed to isolate selected biomarkers from sediment extracts for radiocarbon analysis. Flow injection analysis mass spectrometry was used for rapid analysis of collected fractions to evaluate the separation procedure, taking only 1 min per fraction.

  2. A detailed cost analysis of in vitro fertilization and intracytoplasmic sperm injection treatment.

    Science.gov (United States)

    Bouwmans, Clazien A M; Lintsen, Bea M E; Eijkemans, Marinus J C; Habbema, J Dik F; Braat, Didi D M; Hakkaart, Leona

    2008-02-01

    To provide detailed information about costs of in vitro fertilization (IVF) and intracytoplasmic sperm injection (ICSI) treatment stages and to estimate the cost per IVF and ICSI treatment cycle and ongoing pregnancy. Descriptive micro-costing study. Four Dutch IVF centers. Women undergoing their first treatment cycle with IVF or ICSI. IVF or ICSI. Costs per treatment stage, per cycle started, and for ongoing pregnancy. Average costs of IVF and ICSI hormonal stimulation were euro 1630 and euro 1585; the costs of oocyte retrieval were euro 500 and euro 725, respectively. The cost of embryo transfer was euro 185. Costs per IVF and ICSI cycle started were euro 2381 and euro 2578, respectively. Costs per ongoing pregnancy were euro 10,482 and euro 10,036, respectively. Hormonal stimulation covered the main part of the costs per cycle (on average 68% and 61% for IVF and ICSI, respectively) due to the relatively high cost of medication. The costs of medication increased with increasing age of the women, irrespective of the type of treatment (IVF or ICSI). Fertilization costs (IVF laboratory) constituted 12% and 20% of the total costs of IVF and ICSI. The total cost per ICSI cycle was 8.3% higher than IVF.

  3. Numerical analysis of isothermal JET injection into a denser liquid pool using RD-MPS Method

    Energy Technology Data Exchange (ETDEWEB)

    Park, S. [KEPCO Nuclear Fuel, Daejeon (Korea, Republic of); Park, H. S. [POSTECH, Pohang (Korea, Republic of); Jeun, G. [Hanyang Univ., Seoul (Korea, Republic of)

    2012-03-15

    In this study, the rigid body dynamics coupled moving particle semi-implicit (RD-MPS) method was used to simulate a plunging liquid jet penetrating into a denser liquid pool. The phenomenon is related to fuel-coolant interactions (FCI) during severe accidents in nuclear power plants when coolant water is forcedly injected into a melt pool. A numerical particle method like MPS enables to simulate the complex multiphase flow in that significant deformation of fluids occurs due to its inherent grid less algorithm. However, the MPS method alone cannot continue the calculation for a long time as shown in the Ikea's work due to the large deformation of fluid surfaces and the difference in both liquid densities. In the RD-MPS method, the rigid body dynamics was coupled with the moving particle semi-implicit method to increase the overall stability of calculations and to calculate the multi-phase behavior of fluids. We performed two and three dimensional calculations to simulate jet penetration behaviors in a denser liquid pool, and the result was in good agreement with that of experiment. The simulation results suggested that the coupled model be useful in simulating dynamic interactions of multi-phase incompressible fluids as well as that the 3-D simulation for the plunging jet in a confined geometry predicted better agreement with experimental results than the 2-D simulation did.

  4. Numerical analysis of isothermal JET injection into a denser liquid pool using RD-MPS Method

    International Nuclear Information System (INIS)

    Park, S.; Park, H. S.; Jeun, G.

    2012-01-01

    In this study, the rigid body dynamics coupled moving particle semi-implicit (RD-MPS) method was used to simulate a plunging liquid jet penetrating into a denser liquid pool. The phenomenon is related to fuel-coolant interactions (FCI) during severe accidents in nuclear power plants when coolant water is forcedly injected into a melt pool. A numerical particle method like MPS enables to simulate the complex multiphase flow in that significant deformation of fluids occurs due to its inherent grid less algorithm. However, the MPS method alone cannot continue the calculation for a long time as shown in the Ikea's work due to the large deformation of fluid surfaces and the difference in both liquid densities. In the RD-MPS method, the rigid body dynamics was coupled with the moving particle semi-implicit method to increase the overall stability of calculations and to calculate the multi-phase behavior of fluids. We performed two and three dimensional calculations to simulate jet penetration behaviors in a denser liquid pool, and the result was in good agreement with that of experiment. The simulation results suggested that the coupled model be useful in simulating dynamic interactions of multi-phase incompressible fluids as well as that the 3-D simulation for the plunging jet in a confined geometry predicted better agreement with experimental results than the 2-D simulation did

  5. CFD modelling and analysis of pulverized coal injection in blast furnace: an overview

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Yansong; Yu, Aibing [Laboratory for Simulation and Modelling of Particulate Systems, School of Materials Science and Engineering, The University of New South Wales (UNSW), Sydney, NSW 2052 (Australia); Zulli, Paul [BlueScope Steel Research (BSR), P.O. Box 202, Port Kembla, NSW 2505 (Australia)

    2011-05-15

    In order to understand the complicated phenomena of pulverized coal injection (PCI) process in blast furnace (BF), several mathematical models have been developed by the UNSW and BSR cooperation. These models are featuring from coal combustion in a pilot-scale test rig, to coal combustion in a real BF, and then to coal/coke combustion in a real BF, respectively. This paper reviews these PCI models in aspects of model developments and model applicability. The model development is firstly discussed in terms of model formulation, their new features and geometry/regions considered. The model applicability is then discussed in terms of main findings followed by the model evaluation on their advantages and limitations. It is indicated that the three PCI models are all able to describe PCI operation qualitatively. The model of coal/coke combustion in a real BF is more reliable for simulating in-furnace phenomena of PCI operation qualitatively and quantitatively. Such model gives a more reliable burnout prediction over the raceway surface, which could better represent the amount of unburnt char entering the coke bed. These models are useful for understanding the flow-thermo-chemical behaviours and then optimising the PCI operation in practice. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  6. Clinical analysis of intravitreal injection of triamcinolone acetonide combined macular grid photocoagulation treatment for macular edema

    Directory of Open Access Journals (Sweden)

    Xian-Hua Jing

    2014-10-01

    Full Text Available AIM: To investigate the clinical efficacy and safety of intravitreal injection of triamcinolone combined macular grid photocoagulation treatment for macular edema. METHODS: Totally 150 cases(150 eyeswith macular edema in our hospital from July 2009 to November 2013 were selected, which were randomly divided into study group(75 cases, 75 eyesand control group(75 cases, 75 eyes. The cases in control group were treated with macular grid photocoagulation treatment, those in the study group used triamcinolone acetonide combined macular grid photocoagulation treatment. Best corrected visual acuity(BCVA, parallel optical coherence tomography(OCTand fundus fluorescein angiography(FFAwere detected before treatment, after treatment 7d, 1, 3, and 9mo. RESULTS:After the treatment, patients' vision were significantly improved in two groups(PPPP>0.05. Fovea macular neurosensory retinal thickness in the study group was significantly lower than that in control group(PCONCLUSION: Triamcinolone acetonide combined macular grid photocoagulation treatment is accurate, can effectively improve the visual acuity, reduce macular edema, it is safe and reliable, and suitable for clinical application.

  7. The Efficacy of Guanxinning Injection in Treating Angina Pectoris: Systematic Review and Meta-Analysis of Randomized Controlled Trials

    Science.gov (United States)

    Jia, Yongliang; Leung, Siu-wai; Lee, Ming-Yuen; Cui, Guozhen; Huang, Xiaohui; Pan, Fongha

    2013-01-01

    Objective. The randomized controlled trials (RCTs) on Guanxinning injection (GXN) in treating angina pectoris were published only in Chinese and have not been systematically reviewed. This study aims to provide a PRISMA-compliant and internationally accessible systematic review to evaluate the efficacy of GXN in treating angina pectoris. Methods. The RCTs were included according to prespecified eligibility criteria. Meta-analysis was performed to evaluate the symptomatic (SYMPTOMS) and electrocardiographic (ECG) improvements after treatment. Odds ratios (ORs) were used to measure effect sizes. Subgroup analysis, sensitivity analysis, and metaregression were conducted to evaluate the robustness of the results. Results. Sixty-five RCTs published between 2002 and 2012 with 6064 participants were included. Overall ORs comparing GXN with other drugs were 3.32 (95% CI: [2.72, 4.04]) in SYMPTOMS and 2.59 (95% CI: [2.14, 3.15]) in ECG. Subgroup analysis, sensitivity analysis, and metaregression found no statistically significant dependence of overall ORs upon specific study characteristics. Conclusion. This meta-analysis of eligible RCTs provides evidence that GXN is effective in treating angina pectoris. This evidence warrants further RCTs of higher quality, longer follow-up periods, larger sample sizes, and multicentres/multicountries for more extensive subgroup, sensitivity, and metaregression analyses. PMID:23634167

  8. Biosensing of glucose in flow injection analysis system based on glucose oxidase-quantum dot modified pencil graphite electrode.

    Science.gov (United States)

    Sağlam, Özlem; Kızılkaya, Bayram; Uysal, Hüseyin; Dilgin, Yusuf

    2016-01-15

    A novel amperometric glucose biosensor was proposed in flow injection analysis (FIA) system using glucose oxidase (GOD) and Quantum dot (ZnS-CdS) modified Pencil Graphite Electrode (PGE). After ZnS-CdS film was electrochemically deposited onto PGE surface, GOD was immobilized on the surface of ZnS-CdS/PGE through crosslinking with chitosan (CT). A pair of well-defined reversible redox peak of GOD was observed at GOD/CT/ZnS-CdS/PGE based on enzyme electrode by direct electron transfer between the protein and electrode. Further, obtained GOD/CT/ZnS-CdS/PGE offers a disposable, low cost, selective and sensitive electrochemical biosensing of glucose in FIA system based on the decrease of the electrocatalytic response of the reduced form of GOD to dissolved oxygen. Under optimum conditions (flow rate, 1.3mL min(-1); transmission tubing length, 10cm; injection volume, 100μL; and constant applied potential, -500mV vs. Ag/AgCl), the proposed method displayed a linear response to glucose in the range of 0.01-1.0mM with detection limit of 3.0µM. The results obtained from this study would provide the basis for further development of the biosensing using PGE based FIA systems. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Chemiluminescent determination of vanadium(IV) using a cinchomeronic hydrazide-H2O2 system and flow injection analysis

    International Nuclear Information System (INIS)

    Pradana Perez, J.A.; Alegria, J.S. Durand; Hernando, P. Fernandez; Sierra, A. Narros

    2005-01-01

    This paper proposes a new chemiluminescent flow injection analysis (FIA) method for the determination of vanadium(IV) ions in aqueous media. The method is based on the chemiluminescent reaction that occurs between cinchomeronic hydrazide (CH) and hydrogen peroxide in a strongly alkaline medium, in which vanadium(IV) acts as a catalyst. The chemical and physical variables involved in the flow injection system are optimised using a modified simplex method. Vanadium ions can be detected in the 0.08 and 1.00 μg mL -1 range; the detection limit for a signal-to-noise ratio of 3 is 0.08 μg mL -1 . Great variations in the quantum yield were observed when cobalt(II), chromium(III), copper(II) and/or nickel(II) were present in the reaction medium. The proposed method is selective and simple, and can be successfully used to analyse water samples without the need for separation or preconcentration processes

  10. Annual energy and environment analysis of solarized steam injection gas turbine (STIG) cycle for Indian regions

    International Nuclear Information System (INIS)

    Selwynraj, A. Immanuel; Iniyan, S.; Suganthi, L.; Livshits, Maya; Polonsky, Guy; Kribus, Abraham

    2016-01-01

    Highlights: • Study on the influence of local climatic conditions on solar STIG cycle is presented. • The annual solar to electricity efficiency ranges between 11.2 and 17.1% and the solar fraction ranges 9.3–41.7%. • The range of annual specific CO_2 emission is 312–408 kg/MWh and incremental CO_2 avoidance is 4.2–104 kg/MWh. • The levelized tariff (LT) is 0.2–0.23 $/kWh, and the solar levelized tariff (SLT) ranges from 0.11 to 0.27 $/kWh. - Abstract: The solarized steam injection gas turbine (STIG) cycle uses both the fuel and solar heat simultaneously for power generation. The annual thermodynamic performances of the cycle for sites in India with local climatic conditions such as ambient temperature, relative humidity and availability of direct normal irradiance (DNI) to the solar concentrators under two modes of constant and variable power are presented in this paper. The results reveal that the solar to electricity efficiency of solar hybrid STIG plant with a simple parabolic trough collector (PTC) is similar to existing solar thermal technologies, and also higher solar share is obtained. The study also reveals that the annual CO_2 emission is similar to combined cycle plants and lower than gas turbine technologies. The incremental CO_2 avoidance is also computed due to solar participation. The annual values of exergetic solar fraction and exergetic efficiency at Indore are higher than Jaipur. Results of an improved economic assessment show that the levelized tariff (LT) of solar hybrid STIG plant is 0.2–0.23 $/kWh and the levelized tariff (solar only) or solar levelized tariff (SLT) of solar STIG plant ranges from 0.11 to 0.27 $/kWh for both constant and variable power scenarios.

  11. An analysis of the SCEX 3 ionospheric electron beam injection experiment

    International Nuclear Information System (INIS)

    Goerke, R.T.

    1992-01-01

    The SCEX 3 experiment (Several Compatible EXperiments using a rocket-borne accelerator) was carried to ionospheric altitudes (375 km) by a Black Brant 11 rocket on February 1, 1990. The experiment was launched from Poker Flat Research Range (65.1 degree N, 147.5 degree W) at 1207 UT. The payload split into two parts (hereafter forward and aft payloads) 116 seconds after launch. The aft payload carried two electron accelerators as well as several diagnostic instruments. The forward payload was ejected at an angle of 6 degree with the magnetic field in a northwesterly direction. This payload carried a multiband plasma wave receiver and various particle detectors to make in situ measurements of the Beam Plasma Interaction (BPI) region. Two Throw Away Detectors (TAD's 1 and 2) were also ejected from the aft payload in the east and west directions respectively. TAD 1 also carried a multiband plasma wave receiver. Preceding the launch an auroral arch along the southern boundary of a diffuse auroral patch suddenly brightened, split into two separate arcs and moved to a position north of the rocket's trajectory. SCEX 3 was launched into an active breakup aurora consisting of tall rays and diffuse patches. The purpose of this experiment were (1) to observe injected electrons reflected from the naturally occurring parallel electric field structures which are thought to accelerate the auroral electron, (2) to observe a variety of plasma effects caused by the artificial electron beam and the associated spacecraft charging, and (3) study the natural phenomena associated with auroral activity. This work is a summary of the interesting observations made by the SCEX 3 experiment. These observations include VHF emissions produced by the electron beam via the Beam Plasma Discharge (BPD), Diffuse resonance emissions by the hot plasma region surrounding the electron beam and auroral Z-mode emissions

  12. Long-term Results of Intravitreal Anti-VEGF Injections in Wet AMD: A Meta-Analysis.

    Science.gov (United States)

    Gerding, H

    2016-04-01

    Although intravitreal anti-VEGF medications are widely used in age-related macular degeneration, no systematic data analysis is available on the long-term prognosis of this relatively new therapeutic approach. A meta-analysis was performed on available Medline literature. 13 relevant clinical studies (14 case series) could be identified, covering 10 247 treated eyes. The majority of available reports originate from single centre retrospective real-life environments. The mean improvement in average visual gain was 0.9 ± 0.5 (mean ± 1 standard deviation, median; 0.8 lines) at year 1, 1.2 ± 1.1 (median: 1.1) letters at year 2, 0.7 ± 1.0 (median: 0.7) letters at year 3, and 0.2 ± 0.8 (median: 0.5), 0.4 ± 0.4 (median: 0.5) at years 4 and 5. The drop-out rates in these studies was relatively high. At the end of year 3, the average percentage of observed eyes was 44.3 ± 18.4 % (mean ± 1 standard deviation), at the end of year 4 23.5 ± 23.9 % and after years 6 and 7 below 10 % (8.2 and 7.9 %). The mean treatment frequency of injections in all available studies was highest in year 1 (6.4 ± 1.2, 6.1 - mean ± SD; median), followed by relatively consistent mean values of 4.1 and 5.1 (year (Y)2: 4.4, Y3: 4.3, Y4: 4.7, Y5: 4.1, Y6: 5.1, Y7: 4.7) injections per year. The results of this meta-analysis clearly indicate that intravitreal anti-VEGF injection therapy is capable of maintaining visual acuity on a long-term basis of at least 4-5 years. Georg Thieme Verlag KG Stuttgart · New York.

  13. Temozolomide Injection

    Science.gov (United States)

    ... balance or coordination fainting dizziness hair loss insomnia memory problems pain, itching, swelling, or redness in the place where the medication was injected changes in vision Some side effects can be serious. If you ...

  14. Buprenorphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opiate partial agonists. It works to prevent withdrawal symptoms ... help. If the victim has collapsed, had a seizure, has trouble breathing, or can't be awakened, ...

  15. Risperidone Injection

    Science.gov (United States)

    ... release (long-acting) injection is used to treat schizophrenia (a mental illness that causes disturbed or unusual ... may help control your symptoms but will not cure your condition. Continue to keep appointments to receive ...

  16. Haloperidol Injection

    Science.gov (United States)

    ... haloperidol extended-release injection are used to treat schizophrenia (a mental illness that causes disturbed or unusual ... may help control your symptoms but will not cure your condition. Continue to keep appointments to receive ...

  17. Omalizumab Injection

    Science.gov (United States)

    ... injection is used to decrease the number of asthma attacks (sudden episodes of wheezing, shortness of breath, and ... about how to treat symptoms of a sudden asthma attack. If your asthma symptoms get worse or if ...

  18. Injection Tests

    CERN Document Server

    Kain, V

    2009-01-01

    The success of the start-up of the LHC on 10th of September was in part due to the preparation without beam and injection tests in 2008. The injection tests allowed debugging and improvement in appropriate portions to allow safe, efficient and state-of-the-art commissioning later on. The usefulness of such an approach for a successful start-up becomes obvious when looking at the problems we encountered before and during the injection tests and could solve during this period. The outline of the preparation and highlights of the different injection tests will be presented and the excellent performance of many tools discussed. A list of shortcomings will follow, leading to some planning for the preparation of the run in 2009.

  19. Cefotaxime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefotaxime injection will not work for colds, flu, or other viral infections. Using ...

  20. Cefuroxime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefuroxime injection will not work for colds, flu, or other viral infections. Using ...

  1. Doripenem Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as doripenem injection will not work for colds, flu, or other viral infections. Taking ...

  2. Daptomycin Injection

    Science.gov (United States)

    ... in a class of medications called cyclic lipopeptide antibiotics. It works by killing bacteria.Antibiotics such as daptomycin injection will not work for treating colds, flu, or other viral infections. ...

  3. Ceftaroline Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftaroline injection will not work for colds, flu, or other viral infections. Using ...

  4. Aztreonam Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as aztreonam injection will not work for colds, flu, or other viral infections. Taking ...

  5. Cefazolin Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefazolin injection will not work for colds, flu, or other viral infections. Taking ...

  6. Ceftazidime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftazidime injection will not work for colds, flu, or other viral infections. Using ...

  7. Cefotetan Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefotetan injection will not work for colds, flu, or other viral infections. Using ...

  8. Cefoxitin Injection

    Science.gov (United States)

    ... is in a class of medications called cephamycin antibiotics. It works by killing bacteria.Antibiotics such as cefoxitin injection will not work for colds, flu, or other viral infections. Taking ...

  9. Tigecycline Injection

    Science.gov (United States)

    ... is in a class of medications called tetracycline antibiotics. It works by killing bacteria that cause infection.Antibiotics such as tigecycline injection will not work for colds, flu, or other viral infections. Using ...

  10. Ertapenem Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as ertapenem injection will not work for colds, flu, or other viral infections. Taking ...

  11. Ceftriaxone Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftriaxone injection will not work for colds, flu, or other viral infections.Using ...

  12. Cefepime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefepime injection will not work for colds, flu, or other viral infections. Using ...

  13. Telavancin Injection

    Science.gov (United States)

    ... is in a class of medications called lipoglycopeptide antibiotics. It works by killing bacteria that cause infection.Antibiotics such as telavancin injection will not work for colds, flu, or other viral infections. Using ...

  14. Doxycycline Injection

    Science.gov (United States)

    ... is in a class of medications called tetracycline antibiotics. It works by killing bacteria that cause infections.Antibiotics such as doxycycline injection will not work for colds, flu, or other viral infections. Taking ...

  15. Vancomycin Injection

    Science.gov (United States)

    ... is in a class of medications called glycopeptide antibiotics. It works by killing bacteria that cause infections.Antibiotics such as vancomycin injection will not work for colds, flu, or other viral infections. Taking ...

  16. Octreotide Injection

    Science.gov (United States)

    ... carton and protect it from light. Dispose of multi-dose vials of the immediate-release injection 14 ... and immediately place the medication in a safe location – one that is up and away and out ...

  17. Moxifloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using moxifloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  18. Delafloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using delafloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  19. Levofloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using levofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  20. Ciprofloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using ciprofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  1. Alirocumab Injection

    Science.gov (United States)

    ... 9 (PCSK9) inhibitor monoclonal antibodies. It works by blocking the production of LDL cholesterol in the body ... hives difficulty breathing or swallowing swelling of the face, throat, tongue, lips, and eyes Alirocumab injection may ...

  2. Evolocumab Injection

    Science.gov (United States)

    ... 9 (PCSK9) inhibitor monoclonal antibody. It works by blocking the production of LDL cholesterol in the body ... hives difficulty breathing or swallowing swelling of the face, throat, tongue, lips, and eyes Evolocumab injection may ...

  3. Acyclovir Injection

    Science.gov (United States)

    ... It is also used to treat first-time genital herpes outbreaks (a herpes virus infection that causes sores ... in the body. Acyclovir injection will not cure genital herpes and may not stop the spread of genital ...

  4. Butorphanol Injection

    Science.gov (United States)

    ... Butorphanol is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using butorphanol injection, you may experience withdrawal symptoms such as nervousness, agitation, shakiness, diarrhea, chills, ...

  5. Ultrasound-Guided Versus Landmark-Guided Local Corticosteroid Injection for Carpal Tunnel Syndrome: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.

    Science.gov (United States)

    Babaei-Ghazani, Arash; Roomizadeh, Peyman; Forogh, Bijan; Moeini-Taba, Seyed-Mohammad; Abedini, Amin; Kadkhodaie, Mona; Jahanjoo, Fateme; Eftekharsadat, Bina

    2018-04-01

    To review the literature and assess the comparative effectiveness of ultrasound-guided versus landmark-guided local corticosteroid injections in patients with carpal tunnel syndrome (CTS). Cochrane Central Register of Controlled Trials, MEDLINE (PubMed), Embase (Ovid), and Web of Science (from inception to February 1, 2017). Randomized controlled trials (RCTs) comparing ultrasound-guided injection with landmark-guided injection in patients with CTS were included. Two authors independently screened abstracts and full texts. The outcomes of interest were Symptom Severity Scale (SSS) and Functional Status Scale (FSS) scores of the Boston Carpal Tunnel Questionnaire and 4 electrodiagnostic parameters, including compound muscle action potential (CMAP), sensory nerve action potential (SNAP), distal motor latency (DML), and distal sensory latency (DSL). Overall, 569 abstracts were retrieved and checked for eligibility; finally, 3 RCTs were included (181 injected hands). Pooled analysis showed that ultrasound-guided injection was more effective in SSS improvement (mean difference [MD], -.46; 95% confidence interval [CI], -.59 to -.32; P.99), DML (MD, .05; 95% CI, -.30 to .39; P=.80), or DSL (MD, .00; 95% CI, -.65 to .65; P>.99). This review suggested that ultrasound-guided injection was more effective than landmark-guided injection in symptom severity improvement in patients with CTS; however, no significant differences were observed in functional status or electrodiagnostic improvements between the 2 methods. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  6. Degradation of safety injection system and containment spray piping and tank fracture toughness analysis

    International Nuclear Information System (INIS)

    Douglas, A.; Doubel, P.; Wicker, C.

    2011-01-01

    Extensive stress corrosion cracking (SCC), induced by the marine environment and the presence of high residual stresses arising from the respective manufacturing processes has been encountered in the safety injection system piping (RIS), containment spray system piping (EAS) and reactor and spent fuel storage tank (PTR), or refuelling water storage tank (RWST) of the Koeberg plant. Type 304L steels from the RIS system and replacement components for the RIS and RWST systems have been subject to mechanical and fracture toughness testing. The following conclusions have been drawn. -) The piping sections of both the original and replacement components exhibit residual cold work. The level of cold work imparted to the piping and elbow have been estimated to be 2, 2 to 3, 9% and 5, 7 to 7, 3% respectively. -) Re-annealing produces different responses in type 304L as a function of prior cold work level. Re-annealing of material cold worked to low levels i.e. 3.5% maintain the cold worked level of UTS but can exhibit 0, 2% PS. levels below that of the mill annealed condition. There is the potential for the ASTM A312 minimum 0, 2% level to be breached. At higher levels of cold work i.e. 7% re-annealing results in extensive grain growth, a significant reduction in 0, 2% PS from the mill annealed condition and the recovery of the UTS to the mill annealed level. -) Cold work at the levels obtained significantly reduces the SOL initiation toughness Ji. The reduction in toughness can be greater than 50%. The resistance to ductile crack propagation, dJ/da, remains unchanged at least up to 5 % cold work. -) The defect assessment for the RIS/EAS systems have used highly conservative values of initiation toughness such that no crack initiation would occur under the loading conditions considered and in a non-hostile environment. -) Under the marine environment to which the RIS/EAS components are still subjected, the limiting criterion for operation of the RIS/EAS system remains a

  7. Flow Injection Analysis of Mercury Using 4-(Dimethylamino Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode

    Directory of Open Access Journals (Sweden)

    Sulaiman Ab Ghani

    2012-11-01

    Full Text Available A flow injection analysis (FIA incorporating a thiosemicarbazone-based coated wire electrode (CWE was developed method for the determination of mercury(II. A 0.1 M KNO3 carrier stream with pH between 1 and 5 and flow rate of 1 mL·min−1 were used as optimum parameters. A linear plot within the concentration range of 5 × 10−6–0.1 M Hg(II, slope of 27.8 ± 1 mV per decade and correlation coefficient (R2 of 0.984 were obtained. The system was successfully applied for the determination of mercury(II in dental amalgam solutions and spiked environmental water samples. Highly reproducible measurements with relative standard deviation (RSD < 1% (n = 3 were obtained, giving a typical throughput of 30 samples·h−1.

  8. Design of LabVIEW®-based software for the control of sequential injection analysis instrumentation for the determination of morphine

    Science.gov (United States)

    Lenehan, Claire E.; Lewis, Simon W.

    2002-01-01

    LabVIEW®-based software for the automation of a sequential injection analysis instrument for the determination of morphine is presented. Detection was based on its chemiluminescence reaction with acidic potassium permanganate in the presence of sodium polyphosphate. The calibration function approximated linearity (range 5 × 10-10 to 5 × 10-6 M) with a line of best fit of y=1.05x+8.9164 (R2 =0.9959), where y is the log10 signal (mV) and x is the log10 morphine concentration (M). Precision, as measured by relative standard deviation, was 0.7% for five replicate analyses of morphine standard (5 × 10-8 M). The limit of detection (3σ) was determined as 5 × 10-11 M morphine. PMID:18924729

  9. Design of LabVIEW-based software for the control of sequential injection analysis instrumentation for the determination of morphine.

    Science.gov (United States)

    Lenehan, Claire E; Barnett, Neil W; Lewis, Simon W

    2002-01-01

    LabVIEW-based software for the automation of a sequential injection analysis instrument for the determination of morphine is presented. Detection was based on its chemiluminescence reaction with acidic potassium permanganate in the presence of sodium polyphosphate. The calibration function approximated linearity (range 5 x 10(-10) to 5 x 10(-6) M) with a line of best fit of y=1.05(x)+8.9164 (R(2) =0.9959), where y is the log10 signal (mV) and x is the log10 morphine concentration (M). Precision, as measured by relative standard deviation, was 0.7% for five replicate analyses of morphine standard (5 x 10(-8) M). The limit of detection (3sigma) was determined as 5 x 10(-11) M morphine.

  10. Analysis of the reliability of the active injection safety systems of Angra I

    International Nuclear Information System (INIS)

    Frutuoso e Melo, P.F.F.

    1981-01-01

    The reliability of the active emergency core cooling systems of Angra I nuclear power plant is evaluated. The fault tree analysis is employed. The unavailability of the above cited systems, is calculated. A parametric sensitivity analysis has been performed, due to the existing scattering in the failure and repair rate data of these system's components. The minimal cut sets were determined and, as a final step, a reliability importance analysis has been performed. This final step has required the development of a computer program. The methodology and data from the 'Reactor Safety Study' (Wash-1400) (in which the reliability of safety systems of a tipical PWR plant is calculated), is employed. The unavailability values for the safety systems analysed are too low, thus showing that in most cases the systems analysed are available to mitigate the effects of a loss-of-coolant accident. (Author) [pt

  11. Sequential injection analysis for automation of the Winkler methodology, with real-time SIMPLEX optimization and shipboard application

    Energy Technology Data Exchange (ETDEWEB)

    Horstkotte, Burkhard; Tovar Sanchez, Antonio; Duarte, Carlos M. [Department of Global Change Research, IMEDEA (CSIC-UIB) Institut Mediterrani d' Estudis Avancats, Miquel Marques 21, 07190 Esporles (Spain); Cerda, Victor, E-mail: Victor.Cerda@uib.es [University of the Balearic Islands, Department of Chemistry Carreterra de Valldemossa km 7.5, 07011 Palma de Mallorca (Spain)

    2010-01-25

    A multipurpose analyzer system based on sequential injection analysis (SIA) for the determination of dissolved oxygen (DO) in seawater is presented. Three operation modes were established and successfully applied onboard during a research cruise in the Southern ocean: 1st, in-line execution of the entire Winkler method including precipitation of manganese (II) hydroxide, fixation of DO, precipitate dissolution by confluent acidification, and spectrophotometric quantification of the generated iodine/tri-iodide (I{sub 2}/I{sub 3}{sup -}), 2nd, spectrophotometric quantification of I{sub 2}/I{sub 3}{sup -} in samples prepared according the classical Winkler protocol, and 3rd, accurate batch-wise titration of I{sub 2}/I{sub 3}{sup -} with thiosulfate using one syringe pump of the analyzer as automatic burette. In the first mode, the zone stacking principle was applied to achieve high dispersion of the reagent solutions in the sample zone. Spectrophotometric detection was done at the isobestic wavelength 466 nm of I{sub 2}/I{sub 3}{sup -}. Highly reduced consumption of reagents and sample compared to the classical Winkler protocol, linear response up to 16 mg L{sup -1} DO, and an injection frequency of 30 per hour were achieved. It is noteworthy that for the offline protocol, sample metering and quantification with a potentiometric titrator lasts in general over 5 min without counting sample fixation, incubation, and glassware cleaning. The modified SIMPLEX methodology was used for the simultaneous optimization of four volumetric and two chemical variables. Vertex calculation and consequent application including in-line preparation of one reagent was carried out in real-time using the software AutoAnalysis. The analytical system featured high signal stability, robustness, and a repeatability of 3% RSD (1st mode) and 0.8% (2nd mode) during shipboard application.

  12. Sequential injection analysis for automation of the Winkler methodology, with real-time SIMPLEX optimization and shipboard application

    International Nuclear Information System (INIS)

    Horstkotte, Burkhard; Tovar Sanchez, Antonio; Duarte, Carlos M.; Cerda, Victor

    2010-01-01

    A multipurpose analyzer system based on sequential injection analysis (SIA) for the determination of dissolved oxygen (DO) in seawater is presented. Three operation modes were established and successfully applied onboard during a research cruise in the Southern ocean: 1st, in-line execution of the entire Winkler method including precipitation of manganese (II) hydroxide, fixation of DO, precipitate dissolution by confluent acidification, and spectrophotometric quantification of the generated iodine/tri-iodide (I 2 /I 3 - ), 2nd, spectrophotometric quantification of I 2 /I 3 - in samples prepared according the classical Winkler protocol, and 3rd, accurate batch-wise titration of I 2 /I 3 - with thiosulfate using one syringe pump of the analyzer as automatic burette. In the first mode, the zone stacking principle was applied to achieve high dispersion of the reagent solutions in the sample zone. Spectrophotometric detection was done at the isobestic wavelength 466 nm of I 2 /I 3 - . Highly reduced consumption of reagents and sample compared to the classical Winkler protocol, linear response up to 16 mg L -1 DO, and an injection frequency of 30 per hour were achieved. It is noteworthy that for the offline protocol, sample metering and quantification with a potentiometric titrator lasts in general over 5 min without counting sample fixation, incubation, and glassware cleaning. The modified SIMPLEX methodology was used for the simultaneous optimization of four volumetric and two chemical variables. Vertex calculation and consequent application including in-line preparation of one reagent was carried out in real-time using the software AutoAnalysis. The analytical system featured high signal stability, robustness, and a repeatability of 3% RSD (1st mode) and 0.8% (2nd mode) during shipboard application.

  13. Analysis of the combined effect of hydrogrinding process and inclination angle on hydraulic performance of diesel injection nozzles

    International Nuclear Information System (INIS)

    Salvador, F.J.; Carreres, M.; Jaramillo, D.; Martínez-López, J.

    2015-01-01

    Highlights: • Effect of inclination angle and rounding radius of diesel nozzle holes is explored. • The study starts with experimental tests and is extended by CFD simulations. • A CFD code with a HEM model for two-phase flow and a RANS approach is used. • Differences in flow parameters, cavitation inception and morphology are analysed. • The flow is generally favoured by low inclination angles and high rounding radius. - Abstract: A computational study to investigate the influence of the orifices inclination and the rounding radius at the orifice inlet (consequence of the hydro-erosive grinding process applied after the orifices machining) over the internal nozzle flow is performed in this paper. The study starts with the analysis of experimental results where the mass flow and momentum flux of two nozzles with very different values of these two variables are compared. This analysis shows relatively small differences in terms of mass flow and momentum flux, since the higher losses associated to the higher deflection of the streamlines with a higher inclination of the orifices are counteracted by the higher rounding radius, which favours the flow entrance to the orifice. To explain this experimental outcome, an extensive computational study involving nine geometries that combine different inclination angles and rounding radius is conducted, in order to quantify the influence of both parameters on the flow separately, as well as to assess the potential of their combination. These geometries are compared in terms of discharge coefficient, critical cavitation conditions and effective injection velocity, among others. Results show differences up to 15% in terms of mass flow rate and 8% for the effective injection velocity among the two extreme cases (lowest inclination and highest hydro-erosion level versus the nozzle with the highest inclination and lowest hydro-erosion level). Given the importance of these phenomena on the subsequent mixing and combustion

  14. Preliminary systems-interaction results from the Digraph Matrix Analysis of the Watts Bar Nuclear Power Plant safety-injection systems

    International Nuclear Information System (INIS)

    Sacks, I.J.; Ashmore, B.C.; Champney, J.M.; Alesso, H.P.

    1983-06-01

    This report provides preliminary results generated by a Digraph Matrix Analysis (DMA) for a Systems Interaction analysis performed on the Safety Injection System of the Tennessee Valley Authority Watts Bar Nuclear Power Plant. An overview of DMA is provided along with a brief description of the computer codes used in DMA

  15. Cognitive Task Analysis for Instruction in Single-Injection Ultrasound Guided-Regional Anesthesia

    Science.gov (United States)

    Gucev, Gligor V.

    2012-01-01

    Cognitive task analysis (CTA) is methodology for eliciting knowledge from subject matter experts. CTA has been used to capture the cognitive processes, decision-making, and judgments that underlie expert behaviors. A review of the literature revealed that CTA has not yet been used to capture the knowledge required to perform ultrasound guided…

  16. Mechanical properties test and microstructure analysis of polyoxymethylene (POM) micro injection moulded standard parts

    DEFF Research Database (Denmark)

    Tosello, Guido; Lucchetta, Giovanni; Hansen, Hans Nørgaard

    2009-01-01

    to factorial plans, in which the factors of interest were mould temperature, melt temperature and dimensional range of the specimen (i.e. macro and micro parts). Micro structure analysis was performed by means of plastography techniques and revealed that high mould and melt temperatures resulted on a thin skin...

  17. Cost-effectiveness of exercise therapy after corticosteroid injection for moderate to severe shoulder pain due to subacromial impingement syndrome: a trial-based analysis.

    Science.gov (United States)

    Jowett, Sue; Crawshaw, Dickon P; Helliwell, Philip S; Hensor, Elizabeth M A; Hay, Elaine M; Conaghan, Philip G

    2013-08-01

    To perform a cost-effectiveness analysis of subacromial corticosteroid injection combined with exercise compared with exercise alone in patients with moderate to severe shoulder pain from subacromial impingement syndrome. A within-trial cost-effectiveness analysis with 232 patients randomized to physiotherapy-led injection combined with exercise (n = 115) or exercise alone (n = 117). The analysis was from a health care perspective with 24-week follow-up. Resource use information was collected from all patients on interventions, medication, primary and secondary care contacts, private health care use and over-the-counter purchases. The measure of outcome was quality-adjusted life years (QALYs), calculated from EQ-5D responses at baseline and three further time points. An incremental cost-effectiveness analysis was conducted. Mean per patient NHS costs (£255 vs £297) and overall health care costs (£261 vs £318) were lower in the injection plus exercise arm, but this difference was not statistically significant. Total QALYs gained were very similar in the two trial arms (0.3514 vs 0.3494 QALYs), although slightly higher in the injection plus exercise arm, indicating that injection plus exercise may be the dominant treatment option. At a willingness to pay of £20,000 per additional QALY gained, there was a 61% probability that injection plus exercise was the most cost-effective option. Injection plus exercise delivered by therapists may be a cost-effective use of resources compared with exercise alone and lead to lower health care costs and less time off work. International Standard Randomised Controlled Trial Number Register, http://www.controlled-trials.com/isrctn/, ISRCT 25817033.

  18. Efficacy and safety of flurbiprofen axetil in the prevention of pain on propofol injection: a systematic review and meta-analysis.

    Science.gov (United States)

    Zhang, Lieliang; Zhu, Juan; Xu, Lei; Zhang, Xunlei; Wang, Hongyu; Luo, Zhonghua; Zhao, Yamei; Yu, Yi; Zhang, Yong; Shi, Hongwei; Bao, Hongguang

    2014-06-17

    Pain on injection is an acknowledged adverse effect (AE) of propofol administration for the induction of general anesthesia. Flurbiprofen axetil has been reported to reduce the pain of injection. However, results of published papers on the efficacy of flurbiprofen axetil in managing pain on injection of propofol are inconsistent. We conducted a comprehensive meta-analysis of studies to appraise the efficacy and safety of flurbiprofen axetil for controlling pain induced by propofol injection. The pooled risk ratio (RR) with corresponding 95% confidence intervals (CI) was calculated employing fixed- or random-effects models, depending upon the heterogeneity of the included trials. Compared with the placebo group, flurbiprofen axetil allows more patients to have no pain (RR 3.51, 95% CI 2.22-5.55, p=0.000), and decreases the cumulative number of patients with mild, moderate, and severe pain on injecting propofol (RR 0.70, 95% CI 0.58-0.86, p=0.000; RR 0.59, 95% CI 0.46-0.75, p=0.000; RR 0.25, 95% CI 0.16-0.38, p=0.000, respectively). In the stratified analysis by the doses, flurbiprofen axetil at a dose of over 50 mg was found to be effective in reducing propofol-induced pain on injection; however, there were no significant differences in relieving pain between treatment and placebo groups with flurbiprofen axetil at a dose of 25 mg. In terms of drug safety, there were no adverse effects (AEs) reported between flurbiprofen axetil-based regimens and placebo regimens. Flurbiprofen axetil, an injectable prodrug of flurbiprofen, can significantly prevent or relieve the pain induced by propofol injection. More studies are required to assess its adverse effects.

  19. Micro-bead injection spectroscopy for label-free automated determination of immunoglobulin G in human serum.

    Science.gov (United States)

    Ramos, Inês I; Magalhães, Luís M; Barreiros, Luisa; Reis, Salette; Lima, José L F C; Segundo, Marcela A

    2018-01-01

    Immunoglobulin G (IgG) represents the major fraction of antibodies in healthy adult human serum, and deviations from physiological levels are a generic marker of disease corresponding to different pathologies. Therefore, screening methods for IgG evaluation are a valuable aid to diagnostics. The present work proposes a rapid, automatic, and miniaturized method based on UV-vis micro-bead injection spectroscopy (μ-BIS) for the real-time determination of human serum IgG with label-free detection. Relying on attachment of IgG in rec-protein G immobilized in Sepharose 4B, a bioaffinity column is automatically assembled, where IgG is selectively retained and determined by on-column optical density measurement. A "dilution-and-shoot" approach (50 to 200 times) was implemented without further sample treatment because interferences were flushed out of the column upon sample loading, with minimization of carryover and cross-contamination by automatically discarding the sorbent (0.2 mg) after each determination. No interference from human serum albumin at 60 mg mL -1 in undiluted sample was found. The method allowed IgG determination in the range 100-300 μg mL -1 (corresponding to 5.0-60 mg mL -1 in undiluted samples), with a detection limit of 33 μg mL -1 (1.7 mg mL -1 for samples, dilution factor of 50). RSD values were time-to-result decreased from several hours to times, showing the potential of the proposed approach as a point-of-care method. Graphical abstract Micro-Bead Injection Spectroscopy method for real time, automated and label-free determination of total serum human Immunoglobulin G (IgG). The method was designed for Lab-on-Valve (LOV) platforms using a miniaturised protein G bioaffinity separative approach. IgG are separated from serum matrix components upon quantification with low non-specific binding in less than 5 min.

  20. A meta Analysis of Aidi Injection plus Taxotere and Cisplatin in the Treatment of Non-small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Quan WANG

    2010-11-01

    Full Text Available Background and objective Compared with chemotherapy, whether aidi injection can improve the patient's quality of life is not definite. The aim of this study is to evaluate the efficacy and safety of axotere plus eisplatin chemotherapy combining aidi injection for patients with non-small cell lung cancer (NSCLC. Methods We searched relevant randomized controlled trials (RCTs from Cochrane library, Pubmed, EMBASE, CancerLit, VIP, CBM and CNKI etc. The search was finished in March 20, 2010. We traced the related references and experts in this field, besides we also communicated with other authors to obtain some certain information that has not been found. RCTs of aidi injection plus TP versus TP for advanced NSCLC were included. We evaluated the quality of these included studies and analyzed data by Cochrane Collaboration's RevMan 5.0 software. Results Eleven RCTs involving 800 patients were included. meta analysis results suggested that compared with TP chemotherapy alone, the combination had a statistically significant benefit in healing efficacy (RR=1.2, 95%CI: 1.10-1.47, P=0.001 and improving quality of life (QOL (RR=1.85, 95%Cl: 1.54-2.21, P < 0.001. Besides, the combination also had a statistically significant benefit in myelosuppression, white blood cell (WBC(RR=0.71, 95%CI: 0.57-0.87, P=0.001 and hematoblast (RR=0.59, 95%CI: 0.40-0.87, P=0.008 and in reducing the gastroenteric reaction (RR=0.75, 95%CI: 0.58-0.98, P=0.03. But the combination had no statistically significant benefit in prevention of reducing hemoglobin (Hb (RR=0.97, 95%CI: 0.70-1.34, P=0.85, liver function (RR=0.63, 95%CI: 0.09-1.57, P=0.18, kidney function (RR=0.42, 95%CI: 0.14-1.24, P=0.12, peripheral neuritis (RR=0.86, 95%CI: 0.56-1.32, P=0.50, and baldness (RR=0.92, 95%CI: 0.63-1.34, P=0.66. Conclusion Compared with TP chemotherapy alone, the combination can significantly improve the efficiency, QOL and myelosuppression, and reduce adverse events.

  1. Quantitative profiling of polar metabolites in herbal medicine injections for multivariate statistical evaluation based on independence principal component analysis.

    Directory of Open Access Journals (Sweden)

    Miaomiao Jiang

    Full Text Available Botanical primary metabolites extensively exist in herbal medicine injections (HMIs, but often were ignored to control. With the limitation of bias towards hydrophilic substances, the primary metabolites with strong polarity, such as saccharides, amino acids and organic acids, are usually difficult to detect by the routinely applied reversed-phase chromatographic fingerprint technology. In this study, a proton nuclear magnetic resonance (1H NMR profiling method was developed for efficient identification and quantification of small polar molecules, mostly primary metabolites in HMIs. A commonly used medicine, Danhong injection (DHI, was employed as a model. With the developed method, 23 primary metabolites together with 7 polyphenolic acids were simultaneously identified, of which 13 metabolites with fully separated proton signals were quantified and employed for further multivariate quality control assay. The quantitative 1H NMR method was validated with good linearity, precision, repeatability, stability and accuracy. Based on independence principal component analysis (IPCA, the contents of 13 metabolites were characterized and dimensionally reduced into the first two independence principal components (IPCs. IPC1 and IPC2 were then used to calculate the upper control limits (with 99% confidence ellipsoids of χ2 and Hotelling T2 control charts. Through the constructed upper control limits, the proposed method was successfully applied to 36 batches of DHI to examine the out-of control sample with the perturbed levels of succinate, malonate, glucose, fructose, salvianic acid and protocatechuic aldehyde. The integrated strategy has provided a reliable approach to identify and quantify multiple polar metabolites of DHI in one fingerprinting spectrum, and it has also assisted in the establishment of IPCA models for the multivariate statistical evaluation of HMIs.

  2. Cross sectional analysis of respiratory symptoms in an injection drug user cohort: the impact of obstructive lung disease and HIV

    Directory of Open Access Journals (Sweden)

    Mehta Shruti H

    2010-05-01

    Full Text Available Abstract Background Injection drug use is associated with an increased risk of human immunodeficiency virus (HIV infection and with obstructive lung diseases (OLD. Understanding how HIV and OLD may impact respiratory symptoms among injection drug users (IDUs is important to adequately care for this high-risk population. We characterized the independent and joint effects of HIV and OLD on respiratory symptoms of a cohort of inner-city IDUs. Methods Demographics, risk behavior and spirometric measurements were collected from a cross-sectional analysis of the Acquired Immunodeficiency Syndrome Link to the IntraVenous Experience study, an observational cohort of IDUs followed in Baltimore, MD since 1988. Participants completed a modified American Thoracic Society respiratory questionnaire and the Medical Research Council (MRC dyspnea score to assess respiratory symptoms of cough, phlegm, wheezing and dyspnea. Results Of 974 participants, 835 (86% were current smokers and 288 (29.6% were HIV-infected. The prevalence of OLD (FEV1/FVC ≤ 0.70 was 15.5%, and did not differ by HIV status. OLD, but not HIV, was associated with increased frequency of reported respiratory symptoms. There was a combined effect of OLD and HIV on worsening of MRC scores. OLD and HIV were independently associated with an increased odds of reporting an MRC ≥ 2 (OR 1.83 [95%CI 1.23-2.73] and 1.50 [95%CI 1.08-2.09], respectively. COPD, but not HIV, was independently associated with reporting an MRC ≥ 3 (OR 2.25 [95%CI 1.43-3.54] and 1.29 [95%CI 0.87-1.91], respectively. Conclusions While HIV does not worsen cough, phlegm or wheezing, HIV significantly increases moderate but not severe dyspnea in individuals of similar OLD status. Incorporating the MRC score into routine evaluation of IDUs at risk for OLD and HIV provides better assessment than cough, phlegm and wheezing alone.

  3. Flow injection analysis of sulphide based on its photoelectrocatalytic oxidation at poly-methylene blue modified glassy carbon electrode

    International Nuclear Information System (INIS)

    Dilgin, Yusuf; Canarslan, Seda; Ayyildiz, Onder; Ertek, Bensu; Nişli, Gürel

    2012-01-01

    A new approach for photoelectrocatalytic determination of sulphide in a flow injection analysis (FIA) system was studied using a poly-methylene blue modified glassy carbon electrode (poly-MB/GCE). Results from electrochemical measurements have revealed that poly-MB/GCE is capable of signalling electrocatalytic and photoelectrocatalytic activity towards sulphide oxidation. When the surface of poly-MB/GCE was irradiated with a light source (250 W Halogen lamp), the electrocatalytic current increased substantially. A homemade flow electrochemical cell with a suitable transparent window for the irradiation of the electrode surface was used to perform the photoelectrocatalytic determination of sulphide in FIA system. The currents obtained from the photoamperometric measurements in the FIA system at optimum conditions (carrier solution: pH 9.0 Britton Robinson buffer solution containing 0.1 M KCl; flow rate: 1.3 mL min −1 ; transmission tubing length: 10 cm; injection volume: 100 μL; and constant applied potential: +150 mV vs. Ag/AgCl/KCl sat ) were linearly correlated with the sulphide concentration. The calibration curves were obtained for sulphide concentrations in a range of 0.5–500 μM. The detection limits were found to be 0.27 and 0.15 μM for amperometric and photoamperometric methods, respectively. The proposed method was successfully applied to different wastewaters such as municipal sewage or tannery wastewater. Finally, results from the sulphide measurements by poly-MB/GCE were in good agreement with those attained using spectrophotometric method.

  4. Direct injection analysis of fatty and resin acids in papermaking process waters by HPLC/MS.

    Science.gov (United States)

    Valto, Piia; Knuutinen, Juha; Alén, Raimo

    2011-04-01

    A novel HPLC-atmospheric pressure chemical ionization/MS (HPLC-APCI/MS) method was developed for the rapid analysis of selected fatty and resin acids typically present in papermaking process waters. A mixture of palmitic, stearic, oleic, linolenic, and dehydroabietic acids was separated by a commercial HPLC column (a modified stationary C(18) phase) using gradient elution with methanol/0.15% formic acid (pH 2.5) as a mobile phase. The internal standard (myristic acid) method was used to calculate the correlation coefficients and in the quantitation of the results. In the thorough quality parameters measurement, a mixture of these model acids in aqueous media as well as in six different paper machine process waters was quantitatively determined. The measured quality parameters, such as selectivity, linearity, precision, and accuracy, clearly indicated that, compared with traditional gas chromatographic techniques, the simple method developed provided a faster chromatographic analysis with almost real-time monitoring of these acids. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Second-order Data by Flow Injection Analysis with Spectrophotometric Diode-array Detection and Incorporated Gel-filtration Chromatographic Column

    DEFF Research Database (Denmark)

    Bechmann, Iben Ellegaard

    1997-01-01

    A flow injection analysis (FIA) system furnished with a gel-filtration chromatographic column and with photodiode-array detection was used for the generation of second-order data. The system presented is a model system in which the analytes are blue dextran, potassium hexacyanoferrate(III) and he......A flow injection analysis (FIA) system furnished with a gel-filtration chromatographic column and with photodiode-array detection was used for the generation of second-order data. The system presented is a model system in which the analytes are blue dextran, potassium hexacyanoferrate...

  6. Cellular therapy injections in today's orthopedic market: A social media analysis.

    Science.gov (United States)

    Ramkumar, Prem N; Navarro, Sergio M; Haeberle, Heather S; Chughtai, Morad; Demetriades, Christopher; Piuzzi, Nicolas S; Mont, Michael A; Bauer, Thomas W; Muschler, George F

    2017-12-01

    The current state of cellular therapy for musculoskeletal conditions is at a crossroads. Marketing efforts are often outpacing clinical evidence and regulatory control. This study was an effort to describe the marketing of cellular therapy in musculoskeletal medicine by evaluating the content in popular social media channels. Specifically, media posts were evaluated for the following: (1) perspective, (2) tone, (3) content and (4) visibility. Social media content related to cell therapy for musculoskeletal conditions was assessed in a search using 28 hashtags on the public domains of Instagram and Twitter over a 2-year period (2014-2016) that resulted in analysis of 698 posts. Supplemental analyses of LinkedIn and Facebook domains were also conducted. A categorical scoring system was used to analyze perspective (patient, family or friend, business or organization), tone (positive, negative), content (education, advertisement, research, media coverage or patient experience) and visibility (number of hashtags per post). Sub-analyses of the advertisement content from various perspectives (patients, physicians and businesses) were performed. The media perspective was most frequently from a business or organization (83%; n = 575). A total of 94% of the posts had a positive tone and only 6% had a negative tone, and the only negative posts came from patients (60% positive and 40% negative). The most common content of social media posts were advertisements, representing 68% (n = 477) of all posts; this was confirmed in the Facebook analysis. The mean number of hashtags was five per post. Sub-analyses revealed approximately half of the advertising posts originated from a single business that recruited physicians to market their cell-based therapies on social media, which was confirmed in the LinkedIn analysis. The market messages related to cell-based therapies for musculoskeletal conditions available on social media are dominated by businesses that seem to use a

  7. The Efficacy of Liposomal Bupivacaine Using Periarticular Injection in Total Knee Arthroplasty: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Kuang, Ming-Jie; Du, Yuren; Ma, Jian-Xiong; He, Weiwei; Fu, Lin; Ma, Xin-Long

    2017-04-01

    Total knee arthroplasty (TKA) is gradually emerging as the treatment of choice for end-stage osteoarthritis. In the past, the method of liposomal bupivacaine by periarticular injection (PAI) showed better effects on pain reduction and opioid consumption after surgery. However, some recent studies have reported that liposomal bupivacaine by PAI did not improve pain control and functional recovery in patients undergoing TKA. Therefore, this meta-analysis was conducted to determine whether liposomal bupivacaine provides better pain relief and functional recovery after TKA. Web of Science, PubMed, Embase, and the Cochrane Library were comprehensively searched. Randomized controlled trials, controlled clinical trials, and cohort studies were included in our meta-analysis. Eleven studies that compared liposomal bupivacaine using the PAI technique with the conventional PAI method were included in our meta-analysis. The preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines and Cochrane Handbook were applied to assess the quality of the results published in all included studies to ensure that the results of our meta-analysis were reliable and veritable. Our pooled data analysis demonstrated that liposomal bupivacaine was as effective as the control group in terms of visual analog scale score at 24 hours (P = .46), 48 hours (P = .43), 72 hours (P = .21), total amount of opioid consumption (P = .25), range of motion (P = .28), length of hospital stay (P = .53), postoperative nausea (P = .34), and ambulation distance (P = .07). Compared with the conventional PAI method, liposomal bupivacaine shows similar pain control and functional recovery after TKA. Considering the cost for pain control, liposomal bupivacaine is not worthy of being recommended as a long-acting alternative analgesic agent using the PAI method. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Teduglutide Injection

    Science.gov (United States)

    ... who need additional nutrition or fluids from intravenous (IV) therapy. Teduglutide injection is in a class of medications ... of the ingredients.tell your doctor and pharmacist what other prescription and nonprescription medications, vitamins, nutritional supplements, and herbal products you are taking ...

  9. Dexrazoxane Injection

    Science.gov (United States)

    ... are used to treat or prevent certain side effects that may be caused by chemotherapy medications. Dexrazoxane injection (Zinecard) is used to prevent or decrease heart damage caused by doxorubicin in women who are taking the medication to treat breast cancer that has spread to other parts of the ...

  10. Triptorelin Injection

    Science.gov (United States)

    ... puberty too soon, resulting in faster than normal bone growth and development of sexual characteristics) in children 2 years and older. Triptorelin injection is in a class of medications called gonadotropin-releasing hormone (GnRH) agonists. It works by decreasing the amount ...

  11. Potassium Dehydroandrographolide Succinate Injection for the treatment of child epidemic parotitis: A systematic review and meta-analysis.

    Science.gov (United States)

    Wu, Jia-rui; Zhang, Xiao-meng; Zhang, Bing

    2015-11-01

    To systematically evaluate the clinical efficacy and safety of Potassium Dehydroandrographolide Succinate Injection (PDSI) in the treatment of child epidemic parotitis (EP). Randomized controlled trials (RCTs) regarding PDSI in the treatment of child EP were searched in China National Knowledge Infrastructure, Wanfang Database, Chinese Biomedical Literature Database, PubMed, and Cochrane Library from inception to July 30, 2013. Two reviewers independently retrieved RCTs and extracted information. The Cochrane risk of bias method was used to assess the quality of included studies, and a meta-analysis was conducted with RevMan 5.2 software. A total of 11 studies with 818 participants were included. The quality of the studies was generally low, among which only one study mentioned the random method. The meta-analysis indicated that PDSI was more effective than the conventional therapy with Western medicine for EP in the outcomes of the total effective rate [relative risk (RR)=1.23, 95% confidence interval (CI) [1.14, 1.33], Preview, 2 of which were mainly represented rash and diarrhea in the experiment group, while another 4 ADRs occurred in the control group. Based on the systematic review, PDSI was effectiveness and relatively safety in the treatment of child EP. But further rigorously designed trials are warranted to determine its effectiveness.

  12. Stealthy false data injection attacks using matrix recovery and independent component analysis in smart grid

    Science.gov (United States)

    JiWei, Tian; BuHong, Wang; FuTe, Shang; Shuaiqi, Liu

    2017-05-01

    Exact state estimation is vital important to maintain common operations of smart grids. Existing researches demonstrate that state estimation output could be compromised by malicious attacks. However, to construct the attack vectors, a usual presumption in most works is that the attacker has perfect information regarding the topology and so on even such information is difficult to acquire in practice. Recent research shows that Independent Component Analysis (ICA) can be used for inferring topology information which can be used to originate undetectable attacks and even to alter the price of electricity for the profits of attackers. However, we found that the above ICA-based blind attack tactics is merely feasible in the environment with Gaussian noises. If there are outliers (device malfunction and communication errors), the Bad Data Detector will easily detect the attack. Hence, we propose a robust ICA based blind attack strategy that one can use matrix recovery to circumvent the outlier problem and construct stealthy attack vectors. The proposed attack strategies are tested with IEEE representative 14-bus system. Simulations verify the feasibility of the proposed method.

  13. Analysis and design of lean direct injection fuel nozzles by eddy resolved turbulence simulation

    Science.gov (United States)

    Ryon, Jason Allen

    Combustion systems in gas turbine engines are subjected to particular scrutiny in regards to the emissions which they produce. Of special interest are the emissions of Oxides of Nitrogen (NOx), which have a direct impact on air quality as well as health aspects. There is a need in the industry for elegant designs for these combustion systems which reduce the formation of NOx. The present study includes an in depth analysis of a state-of-the art prefilming airblast injector which is designed for achieving low NOx. The design has been studied through the use of turbulence resolving simulation to differentiate what is important for the design of this system. The OpenFOAM CFD software, with a Delayed Detached Eddy Simulation (DDES) model recently developed at Iowa State University, is shown to provide a suitable design tool which has been used to accurately predict a variety of parameters important to this combustion system. Of particular interest are the mixing characteristics of the atomizer, which have been studied through a series of CFD simulations including single-phase, multi-species, and multi-phase simulations. Turbulence simulations are validated by comparison to United Technologies Aerospace Systems (UTAS) data with air only. It is shown how DDES is able to capture the downstream mixing of air streams. Finally, a novel atomizer has been designed with these methods which is intended to promote thorough mixing. The CFD mixing characteristics are described and compared to the existing injector.

  14. Comparison of field-enhanced and pressure-assisted field-enhanced sample injection techniques for the analysis of water-soluble vitamins using CZE.

    Science.gov (United States)

    Liu, Qingqing; Liu, Yaling; Guan, Yu; Jia, Li

    2009-04-01

    A new online concentration method, namely pressure-assisted field-enhanced sample injection (PA-FESI), was developed and compared with FESI for the analysis of water-soluble vitamins by CZE with UV detection. In PA-FESI, negative voltage and positive pressure were simultaneously applied to initialize PA-FESI. PA-FESI uses the hydrodynamic flow generated by the positive pressure to counterbalance the reverse EOF in the capillary column during electrokinetic sample injection, which allowed a longer injection time than usual FESI mode without compromising the separation efficiency. Using the PA-FESI method, the LODs of the vitamins were at ng/mL level based on the S/N of 3 and the RSDs of migration time and peak area for each vitamin (1 microg/mL) were less than 5.1%. The developed method was applied to the analysis of water-soluble vitamins in corns.

  15. Intake flow and time step analysis in the modeling of a direct injection Diesel engine

    Energy Technology Data Exchange (ETDEWEB)

    Zancanaro Junior, Flavio V.; Vielmo, Horacio A. [Federal University of Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Mechanical Engineering Dept.], E-mails: zancanaro@mecanica.ufrgs.br, vielmoh@mecanica.ufrgs.br

    2010-07-01

    This paper discusses the effects of the time step on turbulence flow structure in the intake and in-cylinder systems of a Diesel engine during the intake process, under the motored condition. The three-dimensional modeling of a reciprocating engine geometry comprising a bowl-in-piston combustion chamber, intake port of shallow ramp helical type and exhaust port of conventional type. The equations are numerically solved, including a transient analysis, valves and piston movements, for engine speed of 1500 rpm, using a commercial Finite Volumes CFD code. A parallel computation is employed. For the purpose of examining the in-cylinder turbulence characteristics two parameters are observed: the discharge coefficient and swirl ratio. This two parameters quantify the fluid flow characteristics inside cylinder in the intake stroke, therefore, it is very important their study and understanding. Additionally, the evolution of the discharge coefficient and swirl ratio, along crank angle, are correlated and compared, with the objective of clarifying the physical mechanisms. Regarding the turbulence, computations are performed with the Eddy Viscosity Model k-u SST, in its Low-Reynolds approaches, with standard near wall treatment. The system of partial differential equations to be solved consists of the Reynolds-averaged compressible Navier-Stokes equations with the constitutive relations for an ideal gas, and using a segregated solution algorithm. The enthalpy equation is also solved. A moving hexahedral trimmed mesh independence study is presented. In the same way many convergence tests are performed, and a secure criterion established. The results of the pressure fields are shown in relation to vertical plane that passes through the valves. Areas of low pressure can be seen in the valve curtain region, due to strong jet flows. Also, it is possible to note divergences between the time steps, mainly for the smaller time step. (author)

  16. Fluoroscopically Guided Extraforaminal Cervical Nerve Root Blocks: Analysis of Epidural Flow of the Injectate with Respect to Needle Tip Position

    Science.gov (United States)

    Shipley, Kyle; Riew, K. Daniel; Gilula, Louis A.

    2013-01-01

    Study Design Retrospective evaluation of consecutively performed fluoroscopically guided cervical nerve root blocks. Objective To describe the incidence of injectate central epidural flow with respect to needle tip position during fluoroscopically guided extraforaminal cervical nerve root blocks (ECNRBs). Methods Between February 19, 2003 and June 11, 2003, 132 consecutive fluoroscopically guided ECNRBs performed with contrast media in the final injected material (injectate) were reviewed on 95 patients with average of 1.3 injections per patient. Fluoroscopic spot images documenting the procedure were obtained as part of standard quality assurance. An independent observer not directly involved in the procedures retrospectively reviewed the images, and the data were placed into a database. Image review was performed to determine optimal needle tip positioning for injectate epidural flow. Results Central epidural injectate flow was obtained in only 28.9% of injections with the needle tip lateral to midline of the lateral mass (zone 2). 83.8% of injectate went into epidural space when the needle tip was medial to midline of the lateral mass (zone 3). 100% of injectate flowed epidurally when the needle tip was medial to or at the medial cortex of the lateral mass (zone 4). There was no statistically significant difference with regards to central epidural flow and the needle tip position on lateral view. Conclusion To ensure central epidural flow with ECNRBs one must be prepared to pass the needle tip medial to midplane of the lateral mass or to medial cortex of the lateral mass. Approximately 16% of ECNRBs with needle tip medial to midline of the lateral mass did not flow into epidural space. One cannot claim a nerve block is an epidural block unless epidural flow of injectate is observed. PMID:24494176

  17. On-line Speciation of Cr(III) and Cr(VI) by Flow Injection Analysis With Spectrophotometric Detection and Chemometrics

    DEFF Research Database (Denmark)

    Diacu, Elena; Andersen, Jens Enevold Thaulov

    2003-01-01

    A flow injection system has been developed, for on-line speciation. of Cr(III) and Cr(VI) by the Diphenylcarbazide (DPC) method with H2O2 oxidation followed by spectrophotometric detection at the 550 nm wavelength. The data thus obtained were subjected to a chemometric analysis (PLS), which showe...

  18. The effect of injection timing on energy and exergy analysis of a diesel engine with biodiesel fuel

    Directory of Open Access Journals (Sweden)

    A Farhadi

    2017-05-01

    Full Text Available Introduction Nowadays, due to higher environmental pollution and decreasing fossil fuels many countries make decisions to use renewable fuels and restrict using of fossil fuels. Renewable fuels generally produce from biological sources. Biodiesel is an alternative diesel fuel derived from the transesterification of vegetable oils, animal fats, or waste frying oils. Considering the differences between diesel and biodiesel fuels, engine condition should be modified based on the fuel or fuel blends to achieve optimum performance. One of the simplest and yet the most widely used models is the thermodynamic model. After verification of the data obtained by model with experimental data it is possible to generalize the extracted data to an unlimited number of functional conditions or unlimited number of fuel types which saves time and reduces costs for experimental engine tests. Using the second law of thermodynamics, it is possible to calculate and analyze the exergy of the engine.4 Materials and Methods In this work, the zero-dimensional model was used to account for internal energy variations, pressure work, heat transfer losses to the solid walls and heat release. The applied assumptions include: The cylinder mixture temperature, pressure and composition were assumed uniform throughout the cylinder. Furthermore, the one-zone thermodynamic model assumes instantaneous mixing between the burned and unburned gases. The cylinder gases were assumed to behave as an ideal gas mixture, Gas properties, include enthalpy, internal energy modeled using polynomial equations associated with temperature. In this research, the equations 1 to 20 were used in Fortran programming language. The results of incylinder pressure obtained by the model were validated by the results of experimental test of OM314 engine. Then the effects of injection timing on Energy and Exergy of the engine were analyzed for B20 fuel. Results and Discussion Comparing the results of the model

  19. Retrospective Analysis of the Accuracy of Ultrasound-Guided Magnetic Resonance Arthrogram Injections of the Hip in the Office Setting.

    Science.gov (United States)

    Jernick, Michael; Walker Gallego, Edward; Nuzzo, Michael

    2017-12-01

    Ultrasound (US)-guided intra-articular hip injections have been proposed in the literature to be accurate, reliable, and safe alternatives to fluoroscopy-guided injections. To evaluate the accuracy of US-guided magnetic resonance (MR) arthrogram injections of the hip performed in the office setting by a single orthopaedic surgeon and elucidate the potential effects that patient age, sex, and body mass index (BMI) have on contrast placement. Case series; Level of evidence, 4. From a review of the senior author's office database, 89 patients (101 hips) who had US-guided MR arthrogram injections performed between December 2014 and June 2016 were identified. Official radiology reports were evaluated to determine whether extra-articular contrast was noted. Patient variables, including BMI, age, and sex, were evaluated between patients who had inappropriately placed contrast and those who did not. Of the 101 hip injections, there were 6 cases that demonstrated inadequate contrast placement within the joint, likely secondary to extravasation or incorrect placement; however, an MR arthrogram was adequately interpreted in all cases. There were no significant differences noted between those with appropriate versus inappropriate contrast placement when evaluating BMI ( P = .57), age ( P = .33), or sex ( P = .67), and neither group had an adverse event. US-guided injections are safe and accurate alternatives to fluoroscopy-guided injections in the office setting, with 94% accuracy. Furthermore, BMI, age, and sex did not play a statistically significant role among patients with inappropriately placed contrast.

  20. Utility of cement injection to stabilize split-depression tibial plateau fracture by minimally invasive methods: A finite element analysis.

    Science.gov (United States)

    Belaid, D; Vendeuvre, T; Bouchoucha, A; Brémand, F; Brèque, C; Rigoard, P; Germaneau, A

    2018-05-08

    Treatment for fractures of the tibial plateau is in most cases carried out by stable fixation in order to allow early mobilization. Minimally invasive technologies such as tibioplasty or stabilization by locking plate, bone augmentation and cement filling (CF) have recently been used to treat this type of fracture. The aim of this paper was to determine the mechanical behavior of the tibial plateau by numerically modeling and by quantifying the mechanical effects on the tibia mechanical properties from injury healing. A personalized Finite Element (FE) model of the tibial plateau from a clinical case has been developed to analyze stress distribution in the tibial plateau stabilized by balloon osteoplasty and to determine the influence of the cement injected. Stress analysis was performed for different stages after surgery. Just after surgery, the maximum von Mises stresses obtained for the fractured tibia treated with and without CF were 134.9 MPa and 289.9 MPa respectively on the plate. Stress distribution showed an increase of values in the trabecular bone in the treated model with locking plate and CF and stress reduction in the cortical bone in the model treated with locking plate only. The computed results of stresses or displacements of the fractured models show that the cement filling of the tibial depression fracture may increase implant stability, and decrease the loss of depression reduction, while the presence of the cement in the healed model renders the load distribution uniform. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Numerical Analysis on the Influence of Thermal Effects on Oil Flow Characteristic in High-Pressure Air Injection (HPAI Process

    Directory of Open Access Journals (Sweden)

    Hu Jia

    2012-01-01

    Full Text Available In previous laboratory study, we have shown the thermal behavior of Keke Ya light crude oil (Tarim oilfield, branch of CNPC for high-pressure air injection (HPAI application potential study. To clarify the influences of thermal effects on oil production, in this paper, we derived a mathematical model for calculating oil flow rate, which is based on the heat conduction property in porous media from the combustion tube experiment. Based on remarkably limited knowledge consisting of very global balance arguments and disregarding all the details of the mechanisms in the reaction zone, the local governing equations are formulated in a dimensionless form. We use finite difference method to solve this model and address the study by way of qualitative analysis. The time-space dimensionless oil flow rate (qD profiles are established for comprehensive studies on the oil flow rate characteristic affected by thermal effects. It also discusses how these findings will impact HPAI project performances, and several guidelines are suggested.

  2. An automatic flow injection analysis procedure for photometric determination of ethanol in red wine without using a chromogenic reagent.

    Science.gov (United States)

    Borges, Sivanildo S; Frizzarin, Rejane M; Reis, Boaventura F

    2006-05-01

    An automatic reagentless photometric procedure for the determination of ethanol in red wine is described. The procedure was based on a falling drop system that was implemented by employing a flow injection analysis manifold. The detection system comprised an infrared LED and a phototransistor. The experimental arrangement was designed to ensure that the wine drop grew between these devices, thus causing a decrease in the intensity of the radiation beam coming from the LED. Since ethanol content affected the size of the wine drop this feature was exploited to develop an analytical procedure for the photometric determination of ethanol in red wine without using a chromogenic reagent. In an attempt to prove the usefulness of the proposed procedure, a set of red wines were analysed. No significant difference between our results and those obtained with a reference method was observed at the 95% confidence level. Other advantages of our method were a linear response ranging from 0.17 up to 5.14 mol L(-1) (1.0 up to 30.0%) ethanol (R = 0.999); a limit of detection of 0.05 mol L(-1) (0.3%) ethanol; a relative standard deviation of 2.5% (n = 10) using typical wine sample containing 2.14 mol L(-1) (12.5%) ethanol; and a sampling rate of 50 determinations per hour.

  3. Flow Injection Analysis with Electrochemical Detection for Rapid Identification of Platinum-Based Cytostatics and Platinum Chlorides in Water

    Directory of Open Access Journals (Sweden)

    Marketa Kominkova

    2014-02-01

    Full Text Available Platinum-based cytostatics, such as cisplatin, carboplatin or oxaliplatin are widely used agents in the treatment of various types of tumors. Large amounts of these drugs are excreted through the urine of patients into wastewaters in unmetabolised forms. This phenomenon leads to increased amounts of platinum ions in the water environment. The impacts of these pollutants on the water ecosystem are not sufficiently investigated as well as their content in water sources. In order to facilitate the detection of various types of platinum, we have developed a new, rapid, screening flow injection analysis method with electrochemical detection (FIA-ED. Our method, based on monitoring of the changes in electrochemical behavior of analytes, maintained by various pH buffers (Britton-Robinson and phosphate buffer and potential changes (1,000, 1,100 and 1,200 mV offers rapid and cheap selective determination of platinum-based cytostatics and platinum chlorides, which can also be present as contaminants in water environments.

  4. Shengmai Injection, a Traditional Chinese Patent Medicine, for Intradialytic Hypotension: A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Chao-yang Chen

    2013-01-01

    Full Text Available Intradialytic hypotension (IDH is a global public health problem. A rising number of IDH sufferers resort to Chinese patent medicine, Shengmai Injection (SMI in China. The objectives of present study are to assess the effectiveness and safety of SMI as an adjunct therapy for IDH. A systematic search of 6 medical databases was performed up to December 2011. Randomized trials involving SMI adjuvant therapy versus conventional therapy were identified. RevMan 5.0 was used for data analysis. Ten randomized clinical trials with 437 participants were identified. Methodological quality was considered inadequate in all trials. Compared with conventional therapy, SMI adjunct therapy showed significant effects in improving the clinic effective rate (P<0.01, decreasing the incidence of IDH episode (P<0.01, decreasing the frequency of nursing interventions (P<0.01, and increasing diastolic blood pressure (P<0.01. There was no statistical significance in the improvement of mean arterial pressure (P=0.22 and systolic blood pressure (P=0.08 between two groups. Four studies had mentioned adverse events, but no serious adverse effects were reported in any of the included trials. In conclusion, SMI adjunct therapy appears to be potentially effective in treatment of IDH and is generally safe. However, further rigorous designed trials are needed.

  5. Carbon paste electrode modified with silver thimerosal for the potentiometric flow injection analysis of silver(I)

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Hosny [Chemistry Department, Faculty of Science, Cairo University, Cairo (Egypt)]. E-mail: dr_hosny@yahoo.com

    2005-07-27

    The utility of carbon paste electrode modified with silver ethylmercurythiosalicylate (silver thimerosal) in both static mode and flow injection analysis (FIA) is demonstrated. The electrode was fully characterized in terms of composition, response time, thermal stability, usable pH and ionic strength ranges. It has been shown that diisononyl phthalate (DINP) acts as more suitable solvent mediator for preparation of the electrode, which exhibits linear response range to Ag(I) extending from 5.0 x 10{sup -7} to 1.0 x 10{sup -3} M with detection limit of 2.5 x 10{sup -7} M and Nernstian slope of 59.3 {+-} 1.0 mV/decade. The proposed chemically modified carbon paste electrode shows a very good selectivity for Ag(I) over a wide variety of metal ions and successfully used for the determination of the silver content of silver sulphadiazine (burning cream) and developed radiological films. The electrode was also used as an indicator electrode in the potentiometric titration of thiopental and thimerosal with AgNO{sub 3}.

  6. Shengmai injection, a traditional chinese patent medicine, for intradialytic hypotension: a systematic review and meta-analysis.

    Science.gov (United States)

    Chen, Chao-Yang; Lu, Ling-Yan; Chen, Peng; Ji, Kang-Ting; Lin, Jia-Feng; Yang, Peng-Lin; Tang, Ji-Fei; Wang, Yan

    2013-01-01

    Intradialytic hypotension (IDH) is a global public health problem. A rising number of IDH sufferers resort to Chinese patent medicine, Shengmai Injection (SMI) in China. The objectives of present study are to assess the effectiveness and safety of SMI as an adjunct therapy for IDH. A systematic search of 6 medical databases was performed up to December 2011. Randomized trials involving SMI adjuvant therapy versus conventional therapy were identified. RevMan 5.0 was used for data analysis. Ten randomized clinical trials with 437 participants were identified. Methodological quality was considered inadequate in all trials. Compared with conventional therapy, SMI adjunct therapy showed significant effects in improving the clinic effective rate (P < 0.01), decreasing the incidence of IDH episode (P < 0.01), decreasing the frequency of nursing interventions (P < 0.01), and increasing diastolic blood pressure (P < 0.01). There was no statistical significance in the improvement of mean arterial pressure (P = 0.22) and systolic blood pressure (P = 0.08) between two groups. Four studies had mentioned adverse events, but no serious adverse effects were reported in any of the included trials. In conclusion, SMI adjunct therapy appears to be potentially effective in treatment of IDH and is generally safe. However, further rigorous designed trials are needed.

  7. DOE/NETL's phase II mercury control technology field testing program: preliminary economic analysis of activated carbon injection.

    Science.gov (United States)

    Jones, Andrew P; Hoffmann, Jeffrey W; Smith, Dennis N; Feeley, Thomas J; Murphy, James T

    2007-02-15

    Based on results of field testing conducted by the U.S. Department of Energy's National Energy Technology Laboratory (DOE/NETL), this article provides preliminary costs for mercury control via conventional activated carbon injection (ACI), brominated ACI, and conventional ACI coupled with the application of a sorbent enhancement additive (SEA) to coal prior to combustion. The economic analyses are reported on a plant-specific basis in terms of the cost required to achieve low (50%), mid (70%), and high (90%) levels of mercury removal "above and beyond" the baseline mercury removal achieved by existing emission control equipment. In other words, the levels of mercury control are directly attributable to ACI. Mercury control costs via ACI have been amortized on a current dollar basis. Using a 20-year book life, levelized costs for the incremental increase in cost of electricity (COE), expressed in mills per kilowatt-hour (mills/kWh), and the incremental cost of mercury control, expressed in dollars per pound of mercury removed ($/lb Hg removed), have been calculated for each level of ACI mercury control. For this analysis, the increase in COE varied from 0.14 mills/kWh to 3.92 mills/kWh. Meanwhile, the incremental cost of mercury control ranged from $3810/lb Hg removed to $166000/lb Hg removed.

  8. Numerical analysis of water hammer induced by injection of subcooled water into steam flow in a horizontal pipe

    International Nuclear Information System (INIS)

    Minato, Akihiko; Nagoyoshi, Takuji; Nakamura, Akira; Fujii, Yuzo; Aya, Izuo; Yamane, Kenji

    2004-01-01

    Subcooled water injection into steam flow in piping systems may generate a water column containing a large steam slug. The steam slug collapses due to rapid condensation and interfaces on both sides collides with each other. Water hammer takes place and sharp pressure pulse propagates through the pipe. The purpose of this study is to show capability of the present numerical simulation method for predictions of pressure transient and loads on a piping system following steam slug collapse. A three-dimensional computer code for transient gas-liquid two-phase flow was applied to simulate an experiment of steam-condensation-induced water hammer with a horizontal polycarbonate pipe. The code was based on the extended two-fluid model, which treated interface motion using the VOF (Volume of Fluid) technique. The Godunov scheme of highly compressible single-phase flow was modified for application to the Riemann problem solution of gas-liquid mixture. Analysis of local steam slug collapse resulted in comparable peak pressure and pulse width of pressure transients with the observation. The calculation of pressure pulse propagation and impact load on piping system showed the quasi-steady pressure load was imposed especially on elbow at 1/10 of water hammer peak pressure. (author)

  9. Flow Injection Analysis

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    1998-01-01

    Learning objectives:* To provide an introduction to automated assays* To describe the basic principles of FIA * To demonstrate the capabilities of FIA in relation to batch assays and conventional continuous flow systems* To show that FIA allows one to augment existing analytical techniques* To sh...... how FIA offers novel analytical procedures which are not feasible by conventional means* To hightlight the potentials of FIA in selected practical assays...

  10. Surface-enhanced Raman detection of RNA and DNA bases following flow-injection analysis or HPLC separation

    Science.gov (United States)

    Cotton, Therese M.; Sheng, Rong-Sheng; Ni, Fan

    1990-11-01

    The goal of this study is to develop Surface-enhanced Raman scattering (SERS) detection methods for flow injection analysis (FIA) and high performance liquid chromatography (HPLC). Nucleic acid bases have been chosen for analysis because of their importance in life processes. The advantages to the use of SERS-based detection include its sensitivity, specificity and versatility. With the development of improved methodology, the detection limits should be comparable to UV spectroscopy. However, the specificity is considerably superior to that obtained with electronic spectroscopy in that the Raman spectrum provides a molecular fingerprint of the individual analytes. Raman spectroscopy is very versatile: aqueous samples, gases and solids can be analyzed with equal facility. The results presented here demonstrate that SERS can be used as a detection method for both FIA and HPLC detection. In the following experiments Ag sols have been used as the active substrate. The effect of various parameters such as temperature, pH, flow rate, and the nature of the interface between the HPLC system and the Raman spectrometer have been examined. One of the most significant findings is that the temperature of the Ag sol/HPLC effluent mixture has a dramatic effect on the SERS intensities. This effect is a result of increased colloid aggregation at higher temperatures. Aggregation is known to produce greater enhancement in SERS and proceeds much more rapidly at elevated temperatures. An increase in the temperature of the Ag sol enables SERS detection under flowing conditions and in real time. This is a substantial improvement over many of the previous attempts to interface SERS detection to FIA or HPLC. In most of the previous studies, it was necessary to stop the flow as the analyte eluted from the chromatogram and measure the SERS spectra under static conditions.

  11. Analysis of microRNA Expression Profiles Induced by Yiqifumai Injection in Rats with Chronic Heart Failure

    Directory of Open Access Journals (Sweden)

    Yu Zhao

    2018-02-01

    Full Text Available Background: Yiqifumai Injection (YQFM is clinically used to treat various cardiovascular diseases including chronic heart failure (CHF. The efficacy of YQFM for treating heart failure has been suggested, but the mechanism of action for pharmacological effects of YQFM is unclear.Methods: Echocardiography detection, left ventricular intubation evaluation, histopathology and immunohistochemical examination were performed in CHF rats to evaluate the cardioprotective effect of YQFM. Rat miRNA microarray and bioinformatics analysis were employed to investigate the differentially expressed microRNAs. In vitro models of AngII-induced hypertrophy and t-BHP induced oxidative stress in H9c2 myocardial cells were used to validate the anti-hypertrophy and anti-apoptosis effects of YQFM. Measurement of cell surface area, ATP content and cell viability, Real-time PCR and Western blot were performed.Results: YQFM significantly improved the cardiac function of CHF rats by increasing left ventricular ejection fraction and fractional shortening, decreasing left ventricular internal diameter and enhancing cardiac output. Seven microRNAs which have a reversible regulation by YQFM treatment were found. Among them, miR-21-3p and miR-542-3p are related to myocardial hypertrophy and cell proliferation, respectively and were further verified by RT-PCR. Target gene network was established and potential related signaling pathways were predicted. YQFM could significantly alleviate AngII induced hypertrophy in cellular model. It also significantly increased cell viabilities and ATP content in t-BHP induced apoptotic cell model. Western blot analysis showed that YQFM could increase the phosphorylation of Akt.Conclusion: Our findings provided scientific evidence to uncover the mechanism of action of YQFM on miRNAs regulation against CHF by miRNA expression profile technology. The results indicated that YQFM has a potential effect on alleviate cardiac hypertrophy and apoptosis

  12. [Cost-effectiveness analysis of schizophrenic patient care settings: impact of an atypical antipsychotic under long-acting injection formulation].

    Science.gov (United States)

    Llorca, P M; Miadi-Fargier, H; Lançon, C; Jasso Mosqueda, G; Casadebaig, F; Philippe, A; Guillon, P; Mehnert, A; Omnès, L F; Chicoye, A; Durand-Zaleski, I

    2005-01-01

    pharmaceutical formulation of antipsychotics. Hospitalization and relapse risks are lower in compliant than in non-compliant patients. The main objective of this pharmacoeconomic analysis is to evaluate the impact in terms of medical benefits and costs of the following strategies: 1. Risperidone long-acting injection: first long-acting injectable atypical antipsychotic; 2. Haloperidol depot: long-acting injectable conventional neuroleptic; 3. Olanzapine: atypical antipsychotic available commercially in oral formulation. The target population defined for the study are young schizophrenic patients treated for at least 1 year and whose disorder has not been diagnosed for longer than 5 years. The time horizon is 2 years. A cost-effectiveness analysis is performed. The perspective adopted is the French Health System. The main hypothesis of the model is that an increase in compliance linked to the use of long-acting injectable formulation could lead to an increased efficacy and a modification of the cost-effectiveness ratio. A decision tree was built. Six periods of follow-up are identified with a duration of 4-months per period. The tree contains 3 principal arms, each one corresponding to a specific treatment: risperidone LA injection, haloperidol decanoate and olanzapine. For each arm, at the chance node, two health states are identified: either the patient responds favourably to the treatment or does not respond favourably and requires a switch to another drug treatment. After a period of response, the patient can either remain in the same state or experiences a clinical deterioration. If the patient presents a clinical deterioration, he can either go back to a positive response state after a period of intensive follow-up or remain in an insufficient response state; in this case, a change of antipsychotic treatment is necessary. In the model, a patient should receive four different treatments before a long-term hospitalization takes put in place. According to the market

  13. Performance Analysis of Cold Energy Recovery from CO2 Injection in Ship-Based Carbon Capture and Storage (CCS

    Directory of Open Access Journals (Sweden)

    Hwalong You

    2014-11-01

    Full Text Available Carbon capture and storage (CCS technology is one of the practical solutions for mitigating the effects of global warming. When captured CO2 is injected into storage sites, the CO2 is subjected to a heating process. In a conventional CO2 injection system, CO2 cold energy is wasted during this heating process. This study proposes a new CO2 injection system that takes advantage of the cold energy using the Rankine cycle. The study compared the conventional system with the new CO2 injection system in terms of specific net power consumption, exergy efficiency, and life-cycle cost (LCC to estimate the economic effects. The results showed that the new system reduced specific net power consumption and yielded higher exergy efficiency. The LCC of the new system was more economical. Several cases were examined corresponding to different conditions, specifically, discharge pressure and seawater temperature. This information may affect decision-making when CCS projects are implemented.

  14. Calculation of eddy viscosity in a compressible turbulent boundary layer with mass injection and chemical reaction, volume 1. [theoretical analysis

    Science.gov (United States)

    Omori, S.

    1973-01-01

    The turbulent kinetic energy equation is coupled with boundary layer equations to solve the characteristics of compressible turbulent boundary layers with mass injection and combustion. The Reynolds stress is related to the turbulent kinetic energy using the Prandtl-Wieghardt formulation. When a lean mixture of hydrogen and nitrogen is injected through a porous plate into the subsonic turbulent boundary layer of air flow and ignited by external means, the turbulent kinetic energy increases twice as much as that of noncombusting flow with the same mass injection rate of nitrogen. The magnitudes of eddy viscosity between combusting and noncombusting flows with injection, however, are almost the same due to temperature effects, while the distributions are different. The velocity profiles are significantly affected by combustion; that is, combustion alters the velocity profile as if the mass injection rate is increased, reducing the skin-friction as a result of a smaller velocity gradient at the wall. If pure hydrogen as a transpiration coolant is injected into a rocket nozzle boundary layer flow of combustion products, the temperature drops significantly across the boundary layer due to the high heat capacity of hydrogen. At a certain distance from the wall, hydrogen reacts with the combustion products, liberating an extensive amount of heat. The resulting large increase in temperature reduces the eddy viscosity in this region.

  15. [Impact analysis of shuxuetong injection on abnormal changes of ALT based on generalized boosted models propensity score weighting].

    Science.gov (United States)

    Yang, Wei; Yi, Dan-Hui; Xie, Yan-Ming; Yang, Wei; Dai, Yi; Zhi, Ying-Jie; Zhuang, Yan; Yang, Hu

    2013-09-01

    To estimate treatment effects of Shuxuetong injection on abnormal changes on ALT index, that is, to explore whether the Shuxuetong injection harms liver function in clinical settings and to provide clinical guidance for its safe application. Clinical information of traditional Chinese medicine (TCM) injections is gathered from hospital information system (HIS) of eighteen general hospitals. This is a retrospective cohort study, using abnormal changes in ALT index as an outcome. A large number of confounding biases are taken into account through the generalized boosted models (GBM) and multiple logistic regression model (MLRM) to estimate the treatment effects of Shuxuetong injections on abnormal changes in ALT index and to explore possible influencing factors. The advantages and process of application of GBM has been demonstrated with examples which eliminate the biases from most confounding variables between groups. This serves to modify the estimation of treatment effects of Shuxuetong injection on ALT index making the results more reliable. Based on large scale clinical observational data from HIS database, significant effects of Shuxuetong injection on abnormal changes in ALT have not been found.

  16. Application of a novel metabolomic approach based on atmospheric pressure photoionization mass spectrometry using flow injection analysis for the study of Alzheimer's disease.

    Science.gov (United States)

    González-Domínguez, Raúl; García-Barrera, Tamara; Gómez-Ariza, José Luis

    2015-01-01

    The use of atmospheric pressure photoionization is not widespread in metabolomics, despite its considerable potential for the simultaneous analysis of compounds with diverse polarities. This work considers the development of a novel analytical approach based on flow injection analysis and atmospheric pressure photoionization mass spectrometry for rapid metabolic screening of serum samples. Several experimental parameters were optimized, such as type of dopant, flow injection solvent, and their flows, given that a careful selection of these variables is mandatory for a comprehensive analysis of metabolites. Toluene and methanol were the most suitable dopant and flow injection solvent, respectively. Moreover, analysis in negative mode required higher solvent and dopant flows (100 µl min(-1) and 40 µl min(-1), respectively) compared to positive mode (50 µl min(-1) and 20 µl min(-1)). Then, the optimized approach was used to elucidate metabolic alterations associated with Alzheimer's disease. Thereby, results confirm the increase of diacylglycerols, ceramides, ceramide-1-phosphate and free fatty acids, indicating membrane destabilization processes, and reduction of fatty acid amides and several neurotransmitters related to impairments in neuronal transmission, among others. Therefore, it could be concluded that this metabolomic tool presents a great potential for analysis of biological samples, considering its high-throughput screening capability, fast analysis and comprehensive metabolite coverage. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Oral and injectable contraceptive use and HIV acquisition risk among women in four African countries: a secondary analysis of data from a microbicide trial.

    Science.gov (United States)

    Balkus, Jennifer E; Brown, Elizabeth R; Hillier, Sharon L; Coletti, Anne; Ramjee, Gita; Mgodi, Nyaradzo; Makanani, Bonus; Reid, Cheri; Martinson, Francis; Soto-Torres, Lydia; Abdool Karim, Salim S; Chirenje, Zvavahera M

    2016-01-01

    To assess the effect of oral and injectable contraceptive use compared to nonhormonal contraceptive use on HIV acquisition among Southern African women enrolled in a microbicide trial. This is a prospective cohort study using data from women enrolled in HIV Prevention Trials Network protocol 035. At each quarterly visit, participants were interviewed about self-reported contraceptive use and sexual behaviors and underwent HIV testing. Cox proportional hazards regression was used to assess the effect of injectable and oral hormonal contraceptive use on HIV acquisition. The analysis included 2830 participants, of whom 106 became HIV infected (4.07 per 100 person-years). At baseline, 1546 (51%) participants reported using injectable contraceptives and 595 (21%) reported using oral contraceptives. HIV incidence among injectable, oral and nonhormonal contraceptive method users was 4.72, 2.68 and 3.83 per 100 person-years, respectively. Injectable contraceptive use was associated with a nonstatistically significant increased risk of HIV acquisition [adjusted hazard ratio (aHR)=1.17; 95% confidence interval (CI) 0.70, 1.96], while oral contraceptive use was associated with a nonstatistically significant decreased risk of HIV acquisition (aHR=0.76; 95% CI 0.37,1.55). In this secondary analysis of randomized trial data, a marginal, but nonstatistically significant, increase in HIV risk among women using injectable hormonal contraceptives was observed. No increased HIV risk was observed among women using oral contraceptives. Our findings support the World Health Organization's recommendation that women at high risk for acquiring HIV, including those using progestogen-only injectable contraception, should be strongly advised to always use condoms and other HIV prevention measures. Among Southern African women participating in an HIV prevention trial, women using injectable hormonal contraceptives had a modest increased risk of HIV acquisition; however, this association was

  18. Postoperative opioid sparing with injectable hydroxypropyl-β-cyclodextrin-diclofenac: pooled analysis of data from two Phase III clinical trials

    Directory of Open Access Journals (Sweden)

    Gan TJ

    2016-12-01

    Full Text Available Tong J Gan,1 Neil Singla,2 Stephen E Daniels,3 Douglas A Hamilton,4,5 Peter G Lacouture,6,7 Christian RD Reyes,8 Daniel B Carr4,9 1Department of Anesthesiology, Stony Brook University, NY, 2Lotus Clinical Research, LLC, Pasadena, CA, 3Premier Research, Austin, TX, 4Javelin Pharmaceuticals, Inc., Cambridge, MA, 5New Biology Ventures, LLC, San Mateo, CA, 6Magidom Discovery, LLC, St Augustine, FL, 7Department of Emergency Medicine, Brown University School of Medicine, Providence, RI, 8Hospira Inc., Lake Forest, IL, 9Department of Anesthesiology, Tufts Medical Center, Boston, MA, USA Purpose: Use of nonopioid analgesics (including nonsteroidal anti-inflammatory drugs for postoperative pain management can reduce opioid consumption and potentially prevent opioid-related adverse events. This study examined the postoperative opioid-sparing effect of repeated-dose injectable diclofenac formulated with hydroxypropyl-β-cyclodextrin (HPβCD-diclofenac. Patients and methods: Pooled data from two double-blind, randomized, placebo- and active comparator-controlled Phase III trials were analyzed. Patients received HPβCD-diclofenac, placebo, or ketorolac by intravenous injection every 6 hours for up to 5 days following abdominal/pelvic or orthopedic surgery. Rescue opioid use was evaluated from the time of first study drug administration to up to 120 hours following the first dose in the overall study population and in subgroups defined by baseline pain severity, age, and HPβCD-diclofenac dose. Results: Overall, 608 patients received ≥1 dose of study medication and were included in the analysis. While 93.2% of patients receiving placebo required opioids, the proportion of patients requiring opioids was significantly lower for patients receiving HPβCD-diclofenac (18.75, 37.5, or 50 mg or ketorolac (P<0.005 for all comparisons. Mean cumulative opioid dose and number of doses were significantly lower among patients receiving HPβCD-diclofenac versus placebo

  19. Acupuncture Compared with Intramuscular Injection of Neostigmine for Postpartum Urinary Retention: A Systematic Review and Meta-Analysis of Randomized Controlled Trials

    Directory of Open Access Journals (Sweden)

    Xiao-Mei Wang

    2018-01-01

    Full Text Available Objective. To compare the effectiveness and safety of acupuncture versus intramuscular injection of neostigmine. Methods. Databases including CNKI, VIP, WanFang, SinoMed, PubMed, Cochrane Library, and clinicaltrials.gov database were retrieved for relevant literature, with the retrieval deadline being November 2017. Two reviewers independently screened, selected, and extracted data and validated the results. The methodological quality was evaluated with the “Risk of Bias” tool, and the meta-analysis was performed by using the RevMan 5.3.5 software. Results. Totally 953 patients with postpartum urinary retention from 15 randomized controlled trials entered the meta-analysis. 12 articles compared the clinical cure rate of acupuncture alone versus intramuscular injection of neostigmine and found the cure rate in the acupuncture group was 2 times that in the neostigmine group (RR, 1.91; 95% CI: 1.66–2.19. 15 articles compared the clinical effectiveness rate of acupuncture alone with that of intramuscular injection of neostigmine and found the clinical effectiveness rate was 28% higher in the acupuncture group than in the neostigmine group (RR: 1.28; 95% CI: 1.16–1.42. No adverse event was reported in the acupuncture group. Conclusion. Acupuncture alone is more effective in treating postpartum urinary retention than intramuscular injection of neostigmine, with good safety profile. Therefore, it is a feasible and valuable technique in clinical settings.

  20. Rapid isolation of biomarkers for compound specific radiocarbon dating using high-performance liquid chromatography and flow injection analysis-atmospheric pressure chemical ionisation mass spectrometry.

    Science.gov (United States)

    Smittenberg, Rienk H; Hopmans, Ellen C; Schouten, Stefan; Sinninghe Damsté, Jaap S

    2002-11-29

    Repeated semi-preparative normal-phase HPLC was performed to isolate selected biomarkers from sediment extracts for radiocarbon analysis. Flow injection analysis-mass spectrometry was used for rapid analysis of collected fractions to evaluate the separation procedure, taking only 1 min per fraction. In this way 100-1000 microg of glycerol dialkyl glycerol tetraethers, sterol fractions and chlorophyll-derived phytol were isolated from typically 100 g of marine sediment, i.e., in sufficient quantities for radiocarbon analysis, without significant carbon isotopic fractionation or contamination.

  1. Injection Drug Use, Unemployment, and Severe Food Insecurity Among HIV-HCV Co-Infected Individuals: A Mediation Analysis.

    Science.gov (United States)

    McLinden, Taylor; Moodie, Erica E M; Hamelin, Anne-Marie; Harper, Sam; Walmsley, Sharon L; Paradis, Gilles; Aibibula, Wusiman; Klein, Marina B; Cox, Joseph

    2017-12-01

    Severe food insecurity (FI), which indicates reduced food intake, is common among HIV-hepatitis C virus (HCV) co-infected individuals. Given the importance of unemployment as a proximal risk factor for FI, this mediation analysis examines a potential mechanism through which injection drug use (IDU) is associated with severe FI. We used biannual data from the Canadian Co-infection Cohort (N = 429 with 3 study visits, 2012-2015). IDU in the past 6 months (exposure) and current unemployment (mediator) were self-reported. Severe FI in the following 6 months (outcome) was measured using the Household Food Security Survey Module. An overall association and a controlled direct effect were estimated using marginal structural models. Among participants, 32% engaged in IDU, 78% were unemployed, and 29% experienced severe FI. After adjustment for confounding and addressing censoring through weighting, the overall association (through all potential pathways) between IDU and severe FI was: risk ratio (RR) = 1.69 (95% confidence interval [CI] = 1.15-2.48). The controlled direct effect (the association through all potential pathways except that of unemployment) was: RR = 1.65 (95% CI = 1.08-2.53). We found evidence of an overall association between IDU and severe FI and estimated a controlled direct effect that is suggestive of pathways from IDU to severe FI that are not mediated by unemployment. Specifically, an overall association and a controlled direct effect that are similar in magnitude suggests that the potential impact of IDU on unemployment is not the primary mechanism through which IDU is associated with severe FI. Therefore, while further research is required to understand the mechanisms linking IDU and severe FI, the strong overall association suggests that reductions in IDU may mitigate severe FI in this vulnerable subset of the HIV-positive population.

  2. Intra-articular injection of methylprednisolone for reducing pain in knee osteoarthritis: A systematic review and meta-analysis.

    Science.gov (United States)

    Tian, Kewei; Cheng, Huiguang; Zhang, Jiangtao; Chen, Ke

    2018-04-01

    To evaluate the efficacy and safety of intra-articular methylprednisolone for reducing pain in patients with knee osteoarthritis. We conduct electronic searches of Medline (1966-2017.11), PubMed (1966-2017.11), Embase (1980-2017.11), ScienceDirect (1985-2017.11), and the Cochrane Library (1900-2017.11) for randomized clinical trials comparing the use of methylprednisolone to treat knee osteoarthritis. The primary outcomes are Western Ontario and McMaster Universities Arthritis Index (WOMAC) pain scores and WOMAC function scores. Each outcome was combined and calculated using the statistical software STATA 12.0. Fixed/random effect model was adopted based on the heterogeneity tested by I statistic. A total of 739 patients were analyzed across 4 randomized controlled trials (RCTs). The present meta-analysis revealed that there were significant differences between groups regarding the WOMAC pain scores at 4 weeks (WMD = -1.384, 95% CI: -1.975 to -0.793, P = .000), 12 weeks (WMD = -1.587, 95% CI: -2.489 to -0.685, P = .001), and 24 weeks (WMD = -1.563, 95% CI: -2.245 to -0.881, P = .000). Significant differences were identified in terms of physical function at 4 weeks (WMD = -7.925, 95% CI: -13.359 to -2.491, P = .004), 12 weeks (WMD = -7.314, 95% CI: -13.308 to -1.320, P = .117), and 24 weeks (WMD = -6.484, 95% CI: -11.256 to -1.711, P = .008). Intra-articular methylprednisolone injection was associated with an improved pain relief and physical function in patients with knee osteoarthritis. Additionally, no severe adverse effects were observed. Due to the limited quality of the evidence currently available, higher quality RCTs were required.

  3. Use of testicular sperm for intracytoplasmic sperm injection in men with high sperm DNA fragmentation: a SWOT analysis.

    Science.gov (United States)

    Esteves, Sandro C; Roque, Matheus; Garrido, Nicolás

    2018-01-01

    Spermatozoa retrieved from the testis of men with high levels of sperm DNA fragmentation (SDF) in the neat semen tend to have better DNA quality. Given the negative impact of SDF on the outcomes of Assisted Reproductive Technology (ART), an increased interest has emerged about the use of testicular sperm for intracytoplasmic sperm injection (Testi-ICSI). In this article, we used a SWOT (strengths, weaknesses, opportunities, and threats) analysis to summarize the advantages and drawbacks of this intervention. The rationale of Testi-ICSI is bypass posttesticular DNA fragmentation caused by oxidative stress during sperm transit through the epididymis. Hence, oocyte fertilization by genomically intact testicular spermatozoa may be optimized, thus increasing the chances of creating a normal embryonic genome and the likelihood of achieving a live birth, as recently demonstrated in men with high SDF. However, there is still limited evidence as regards the clinical efficacy of Testi-ICSI, thus creating opportunities for further confirmatory clinical research as well as investigation of Testi-ICSI in clinical scenarios other than high SDF. Furthermore, Testi-ICSI can be compared to other laboratory preparation methods for deselecting sperm with damaged DNA. At present, the available literature supports the use of testicular sperm when performing ICSI in infertile couples whose male partners have posttesticular SDF. Due to inherent risks of sperm retrieval, Testi-ICSI should be offered when less invasive treatments for alleviating DNA damage have failed. A call for continuous monitoring is nonetheless required concerning the health of generated offspring and the potential complications of sperm retrieval.

  4. Effect of Cervical Interlaminar Epidural Steroid Injection: Analysis According to the Neck Pain Patterns and MRI Findings

    Science.gov (United States)

    Choi, Ji Won; Lim, Hyung Woo; Lee, Jin Young; Lee, Won Il; Lee, Eun Kyung; Chang, Choo Hoon; Yang, Jae Young

    2016-01-01

    Background It is widely accepted that cervical interlaminar steroid injection (CIESI) is more effective in treating radicular pain than axial neck pain, but without direct comparison. And the differences of effect after CIESI according to MRI findings are inconsistent. In this retrospective study, we evaluated the therapeutic response of CIESI according to pain sites, durations, MRI findings, and other predictive factors altogether, unlike previous studies, which evaluated them separately. Methods The medical records of 128 patients who received fluoroscopy guided CIESI were analyzed. We evaluated the therapeutic response (more than a 50% reduction on the visual analog scale [VAS] by their second visit) after CIESI by (1) pain site; neck pain without radicular pain/radicular pain with or without neck pain, (2) pain duration; acute/chronic (more than 6 month), and (3) findings of MRI; herniated intervertebral disc (HIVD)/spinal stenosis, respectively and altogether. Results Eighty-eight patients (68%) responded to CIESI, and there were no significant differences in demographic data, initial VAS score, or laboratory findings. And there were no significant differences in the response rate relating to pain site, pain duration, or MRI findings, respectively. In additional analysis, acute radicular pain with HIVD patients showed significantly better response than chronic neck pain with spinal stenosis (P = 0.04). Conclusions We cannot find any sole predictive factor of therapeutic response to the CIESI. But the patients having acute radicular pain with HIVD showed the best response, and those having other chronic neck pain showed the worst response to CIESI. PMID:27103964

  5. Characterizing the Potential for Injection-Induced Fault Reactivation Through Subsurface Structural Mapping and Stress Field Analysis, Wellington Field, Sumner County, Kansas

    Science.gov (United States)

    Schwab, Drew R.; Bidgoli, Tandis S.; Taylor, Michael H.

    2017-12-01

    Kansas, like other parts of the central U.S., has experienced a recent increase in seismicity. Correlation of these events with brine disposal operations suggests pore fluid pressure increases are reactivating preexisting faults, but rigorous evaluation at injection sites is lacking. Here we determine the suitability of CO2 injection into the Cambrian-Ordovician Arbuckle Group for long-term storage and into a Mississippian reservoir for enhanced oil recovery in Wellington Field, Sumner County, Kansas. To determine the potential for injection-induced earthquakes, we map subsurface faults and estimate in situ stresses, perform slip and dilation tendency analyses to identify well-oriented faults relative to the estimated stress field, and determine the pressure changes required to induce slip at reservoir and basement depths. Three-dimensional seismic reflection data reveal 12 near-vertical faults, mostly striking NNE, consistent with nodal planes from moment tensor solutions from recent earthquakes in the region. Most of the faults cut both reservoirs and several clearly penetrate the Precambrian basement. Drilling-induced fractures (N = 40) identified from image logs and inversion of earthquake moment tensor solutions (N = 65) indicate that the maximum horizontal stress is approximately EW. Slip tendency analysis indicates that faults striking <020° are stable under current reservoir conditions, whereas faults striking 020°-049° may be prone to reactivation with increasing pore fluid pressure. Although the proposed injection volume (40,000 t) is unlikely to reactive faults at reservoir depths, high-rate injection operations could reach pressures beyond the critical threshold for slip within the basement, as demonstrated by the large number of injection-induced earthquakes west of the study area.

  6. Experimental investigation and combustion analysis of a direct injection dual-fuel diesel-natural gas engine

    Energy Technology Data Exchange (ETDEWEB)

    Carlucci, A.P.; De Risi, A.; Laforgia, D.; Naccarato, F. [Department of Engineering for Innovation, University of Salento, CREA, via per Arnesano, 73100 Lecce (Italy)

    2008-02-15

    A single-cylinder diesel engine has been converted into a dual-fuel engine to operate with natural gas together with a pilot injection of diesel fuel used to ignite the CNG-air charge. The CNG was injected into the intake manifold via a gas injector on purpose designed for this application. The main performance of the gas injector, such as flow coefficient, instantaneous mass flow rate, delay time between electrical signal and opening of the injector, have been characterized by testing the injector in a constant-volume optical vessel. The CNG jet structure has also been characterized by means of shadowgraphy technique. The engine, operating in dual-fuel mode, has been tested on a wide range of operating conditions spanning different values of engine load and speed. For all the tested operating conditions, the effect of CNG and diesel fuel injection pressure, together with the amount of fuel injected during the pilot injection, were analyzed on the combustion development and, as a consequence, on the engine performance, in terms of specific emission levels and fuel consumption. (author)

  7. Efficacy of Compound Kushen Injection in Relieving Cancer-Related Pain: A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Yu-ming Guo

    2015-01-01

    Full Text Available Despite widespread popular use of complementary and alternative medicine (CAM therapies, a rigorous evidence based on the efficacy of compound kushen injection (CKI for cancer-related pain is lacking. In this study, we evaluated the efficacy and safety of compound kushen injection and provided information for current or future research and clinical application. Sixteen trials were identified with a total of 1564 patients. The total pain relief rate of CKI plus chemotherapy is better than chemotherapy except for colorectal cancer. The treatment groups achieved a reduction in the incidences of leukopenia and gastrointestinal, hepatic, and renal functional lesion. However, there is paucity of multi-institutional RCTs evaluating compound kushen injection for cancer pain with adequate power, duration, and sham control. The quantity and quality of RCTs are lower so that we still have to boost the research level through scientific design and normative report.

  8. Characterization and analysis of weld lines on micro-injection moulded parts using atomic force microscopy (AFM)

    DEFF Research Database (Denmark)

    Tosello, Guido; Gava, Alberto; Hansen, Hans Nørgaard

    2009-01-01

    In recent years plastic moulding techniques, such as injection moulding, have been developed to fulfil the needs of micro-components fabrication. Micro-injection moulding (SLIM) is the process which enables the mass production of polymer micro-systems such as micro-mechanical parts, micro...... the two original flows will generate and a weld line is formed on the surface of the micro-moulded part. This phenomenon has to be avoided or at least reduced, since in the weld line area the mechanical properties are poorer than in the bulk part, creating strength problems on the final part. Although...... injection moulding parameters on the weld lines' dimensions is presented, using an atomic force microscope (AFM). Depth and width of weld lines were chosen as parameters to be optimized....

  9. Performance analysis of a small regenerative gas turbine system adopting steam injection and side-wall in finned tube evaporator

    International Nuclear Information System (INIS)

    Kang, Soo Young; Lee, Jong Jun; Kim, Tong Seop

    2009-01-01

    Small gas turbines in power range of several MWs are quite suitable for application in distributed generation as well as Community Energy Systems (CES). Humidification is an effective way to improve gas turbine performance, and steam injection is the most general and practically feasible method. This study intended to examine the effect of steam injection on the performance of several MW class gas turbines. A primary concern is given to the regenerative cycle gas turbine. The steam injection effect on the performance of a system without the regenerator (i.e. a simple cycle) is also examined. In addition, the influence of bypass of some of the exhaust gas on the performance of the gas turbine, especially the regenerative cycle gas turbine, is evaluated.

  10. Xuebijing Injection Combined with Antibiotics for the Treatment of Spontaneous Bacterial Peritonitis in Liver Cirrhosis: A Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Dan Han

    2018-01-01

    Full Text Available Background and Aim. Spontaneous bacterial peritonitis (SBP is one of the most common complications of liver cirrhosis. Antibiotics are the main treatment regimen of SBP. Traditional Chinese medicine Xuebijing injection has been used in such patients. Our study aimed to overview the efficacy of Xuebijing injection combined with antibiotics for the treatment of SBP. Method. We searched the PubMed, Embase, China National Knowledge Infrastructure, VIP, and Wanfang databases. The search items included “Xuebijing”, “peritonitis”, “liver cirrhosis”, and “random” to identify all relevant randomized controlled trials (RCTs. The Cochrane risk of bias tool was used to assess the study quality. The odd ratios (ORs with 95% confidence intervals (CIs were calculated by using a random-effect model. Heterogeneity was also calculated. Results. A total of 9 RCTs were included. The study quality was unsatisfied. The overall (OR = 2.95, 95% CI = 1.97–4.42, p<0.00001 and complete (OR = 2.18, 95% CI = 1.57–3.04, p<0.00001 responses were significantly higher in the Xuebijing injection combined with antibiotics group than the antibiotics alone group. The incidence of cirrhosis related complications, including hepatic encephalopathy and hepatorenal syndrome, was lower in the Xuebijing injection combined with antibiotics group than the antibiotics alone group. No significant heterogeneity was observed among studies. Conclusion. Additional use of Xuebijing injection may improve the efficacy of antibiotics for the treatment of SBP in liver cirrhosis. However, due to a low level of current evidence, we did not establish any recommendation regarding the use of Xuebijing injection for the treatment of SBP.

  11. Analysis of mixture formation of direct injection gasoline engine; Tonai funsha gasoline engine no kongoki keisei kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    Kano, M; Saito, K; Basaki, M [Nippon Soken, Inc., Tokyo (Japan); Matsushita, S; Gono, T [Toyota Motor Corp., Aichi (Japan)

    1997-10-01

    On direct injection gasoline engine, in order to achieve good stratified combustion, the extremely advanced control of air-fuel mixture is required. For this purpose, the method of diagnosing the quality of the state of mixture formation in combustion chambers becomes necessary. In this research, the state of air-fuel mixture in the combustion chamber of a TOYOTA D-4 was analyzed in space and time by visualization, A/F multi-point measurement and A/F high response measurement, thus the effects that injection timing, swirl and fuel pressure exerted to mixture formation were elucidated. 3 refs., 17 figs., 1 tab.

  12. Gene expression analysis of the emergence of epileptiform activity after focal injection of kainic acid into mouse hippocampus

    DEFF Research Database (Denmark)

    Motti, Dario; Le Duigou, Caroline; Eugène, Emmanuel

    2010-01-01

    and contralateral hippocampus participated in the status epilepticus. However, neuronal death induced by KA treatment was restricted to the injected hippocampus, although there was some contralateral axonal degeneration. We profiled gene expression changes in dorsal and ventral regions of both the injected...... and contralateral hippocampus. Changes were detected in the expression of 1526 transcripts in samples from three time-points: (i) during the KA-induced status epilepticus, (ii) at 2 weeks, before recurrent seizures emerged, and (iii) at 6 months after seizures emerged. Grouping genes with similar spatio...

  13. Pre-column dilution large volume injection ultra-high performance liquid chromatography-tandem mass spectrometry for the analysis of multi-class pesticides in cabbages.

    Science.gov (United States)

    Zhong, Qisheng; Shen, Lingling; Liu, Jiaqi; Yu, Dianbao; Li, Siming; Yao, Jinting; Zhan, Song; Huang, Taohong; Hashi, Yuki; Kawano, Shin-ichi; Liu, Zhaofeng; Zhou, Ting

    2016-04-15

    Pre-column dilution large volume injection (PD-LVI), a novel sample injection technique for reverse phase ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), was developed in this study. The PD-LVI UHPLC-MS/MS system was designed by slightly modifying the commercial UHPLC-MS/MS equipment with a mixer chamber. During the procedure of PD-LVI, sample solution of 200μL was directly carried by the organic mobile phase to the mixer and diluted with the aqueous mobile phase. After the mixture was introduced to the UHPLC column in a mobile phase of acetonitrile-water (15/85, v/v), the target analytes were stacked on the head of the column until following separation. Using QuEChERS extraction, no additional steps such as solvent evaporation or residue redissolution were needed before injection. The features of PD-LVI UHPLC-MS/MS system were systematically investigated, including the injection volume, the mixer volume, the precondition time and the gradient elution. The efficiency of this approach was demonstrated by direct analysis of 24 pesticides in cabbages. Under the optimized conditions, low limits of detection (0.00074-0.8 ng/kg) were obtained. The recoveries were in the range of 63.3-109% with relative standard deviations less than 8.1%. Compared with common UHPLC-MS/MS technique, PD-LVI UHPLC-MS/MS showed significant advantages such as excellent sensitivity and reliability. The mechanism of PD-LVI was demonstrated to be based on the column-head stacking effect with pre-column dilution. Based on the results, PD-LVI as a simple and effective sample injection technique of reverse phase UHPLC-MS/MS for the analysis of trace analytes in complex samples showed a great promising prospect. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Results: Safe injection procedures regarding final waste disposal were sufficiently adopted, while measures regarding disposable injection equipment, waste containers, hand hygiene, as well as injection practices were inadequately carried out. Lack of job aid posters that promote safe injection and safe disposal of ...

  15. Reliability analysis for the safety injection (SI) system of the Doel I - II power plant in case of a LOCA

    International Nuclear Information System (INIS)

    Meester, P. de; Poucet, A.

    1978-01-01

    An assement is made for the failure probability of the safety injection system of the Doel power plant. The SI system is composed of three subsystems: high pressure, low pressure and accumulator system. For each subsystem a fault tree is constructed and these fault trees are evaluated by a computer code which calculates the mean system failure probability and the error bounds. (author)

  16. Using phylogenetic analysis to trace HIV-1 migration among western European injecting drug users seroconverting from 1984 to 1997

    NARCIS (Netherlands)

    Op de Coul, E. L.; Prins, M. [= Maria; Cornelissen, M.; van der Schoot, A.; Boufassa, F.; Brettle, R. P.; Hernández-Aguado, L.; Schiffer, V.; McMenamin, J.; Rezza, G.; Robertson, R.; Zangerle, R.; Goudsmit, J.; Coutinho, R. A.; Lukashov, V. V.

    2001-01-01

    OBJECTIVE: To reconstruct the epidemiological relationships of the HIV epidemics among injecting drug users (IDU) in western Europe. METHODS: HIV env V3 sequences of and epidemiological data were obtained from 145 IDU who seroconverted in three sequential periods: 1984-1988, 1989-1992 and 1993-1997.

  17. Ruby lidar observations and trajectory analysis of stratospheric aerosols injected by the volcanic eruptions of El Chichon

    Science.gov (United States)

    Uchino, O.; Tabata, T.; Akita, I.; Okada, Y.; Naito, K.

    1985-01-01

    Large amounts of aerosol particles and gases were injected into the lower stratosphere by the violet volcanic eruptions of El Chichon on March 28, and April 3 and 4, 1982. Observational results obtained by a ruby lidar at Tsukuba (36.1 deg N, 140.1 deg E) are shown, and some points of latitude dispersion processes of aerosols are discussed.

  18. Information contained within the large scale gas injection test (Lasgit) dataset exposed using a bespoke data analysis tool-kit

    International Nuclear Information System (INIS)

    Bennett, D.P.; Thomas, H.R.; Cuss, R.J.; Harrington, J.F.; Vardon, P.J.

    2012-01-01

    Document available in extended abstract form only. The Large Scale Gas Injection Test (Lasgit) is a field scale experiment run by the British Geological Survey (BGS) and is located approximately 420 m underground at SKB's Aespoe Hard Rock Laboratory (HRL) in Sweden. It has been designed to study the impact on safety of gas build up within a KBS-3V concept high level radioactive waste repository. Lasgit has been in almost continuous operation for approximately seven years and is still underway. An analysis of the dataset arising from the Lasgit experiment with particular attention to the smaller scale features and phenomenon recorded has been undertaken in parallel to the macro scale analysis performed by the BGS. Lasgit is a highly instrumented, frequently sampled and long-lived experiment leading to a substantial dataset containing in excess of 14.7 million datum points. The data is anticipated to include a wealth of information, including information regarding overall processes as well as smaller scale or 'second order' features. Due to the size of the dataset coupled with the detailed analysis of the dataset required and the reduction in subjectivity associated with measurement compared to observation, computational analysis is essential. Moreover, due to the length of operation and complexity of experimental activity, the Lasgit dataset is not typically suited to 'out of the box' time series analysis algorithms. In particular, the features that are not suited to standard algorithms include non-uniformities due to (deliberate) changes in sample rate at various points in the experimental history and missing data due to hardware malfunction/failure causing interruption of logging cycles. To address these features a computational tool-kit capable of performing an Exploratory Data Analysis (EDA) on long-term, large-scale datasets with non-uniformities has been developed. Particular tool-kit abilities include: the parameterization of signal variation in the dataset

  19. Quality evaluation of Guan-Xin-Ning injection based on fingerprint analysis and simultaneous separation and determination of seven bioactive constituents by capillary electrophoresis.

    Science.gov (United States)

    Xu, Liying; Chang, Ruimiao; Chen, Meng; Li, Lou; Huang, Yayun; Zhang, Hongfen; Chen, Anjia

    2017-12-01

    The purpose of this study was to develop a comprehensive, rapid and practical capillary electrophoresis (CE) method for quality control (QC) of Guan-Xin-Ning (GXN) injection based on fingerprint analysis and simultaneous separation and determination of seven constituents. In fingerprint analysis, a capillary zone electrophoresis (CZE) method with a running buffer of 30 mM borate solution (pH 9.3) was established. Meanwhile, ten batches of samples were used to establish the fingerprint electropherogram and 34 common peaks were obtained within 20 min. The RSD of relative migration times (RMT) and relative peak areas (RPA) were less than 5%. In order to further evaluate the quality of GXN injection, a micellar electrokinetic chromatography (MEKC) method was developed for simultaneous separation and determination of bioactive constituents. Seven components reached baseline separation with a running buffer containing 35 mM SDS and 45 mM borate solution (pH 9.3). A good linearity was obtained with correlation coefficients from 0.9906 to 0.9997. The LOD and LOQ ranged from 0.12 to 1.50 μg/mL and from 0.40 to 4.90 μg/mL, respectively. The recoveries ranged between 99.0 and 104.4%. Therefore, it was concluded that the proposed method can be used for full-scale quality analysis of GXN injection. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Hydrodynamic analysis of clastic injection and hydraulic fracturing structures in the Jinding Zn-Pb deposit, Yunnan, China

    Directory of Open Access Journals (Sweden)

    Guoxiang Chi

    2012-01-01

    Full Text Available The Jinding Zn-Pb deposit has been generally considered to have formed from circulating basinal fluids in a relatively passive way, with fluid flow being controlled by structures and sedimentary facies, similar to many other sediments-hosted base metal deposits. However, several recent studies have revealed the presence of sand injection structures, intrusive breccias, and hydraulic fractures in the open pit of the Jinding deposit and suggested that the deposit was formed from explosive release of overpressured fluids. This study reports new observations of fluid overpressure-related structures from underground workings (Paomaping and Fengzishan, which show clearer crosscutting relationships than in the open pit. The observed structures include: 1 sand (±rock fragment dikes injecting into fractures in solidified rocks; 2 sand (±rock fragment bodies intruding into unconsolidated or semi-consolidated sediments; 3 disintegrated semi-consolidated sand bodies; and 4 veins and breccias formed from hydraulic fracturing of solidified rocks followed by cementation of hydrothermal minerals. The development of ore minerals (sphalerite in the cement of the various clastic injection and hydraulic fractures indicate that these structures were formed at the same time as mineralization. The development of hydraulic fractures and breccias with random orientation indicates small differential stress during mineralization, which is different from the stress field with strong horizontal shortening prior to mineralization. Fluid flow velocity may have been up to more than 11 m/s based on calculations from the size of the fragments in the clastic dikes. The clastic injection and hydraulic fracturing structures are interpreted to have formed from explosive release of overpressured fluids, which may have been related to either magmatic intrusions at depth or seismic activities that episodically tapped an overpressured fluid reservoir. Because the clastic injection

  1. Analysis of dual-mode lasing characteristics in a 1310-nm optically injected quantum dot distributed feedback laser

    Science.gov (United States)

    Raghunathan, R.; Olinger, J.; Hurtado, A.; Grillot, F.; Kovanis, V.; Lester, L. F.

    2015-03-01

    Recent work has shown the Quantum Dot (QD) material system to be well-suited to support dual-mode lasing. In particular, optical injection from a master laser (ML) into the residual Fabry-Perot (FP) modes of a 1310 nm Quantum Dot Distributed Feedback (QD-DFB) laser has been recently demonstrated to offer a highly reliable platform for stable dual-mode lasing operation. External controls on the ML, such as operating temperature and bias current, can be used to precisely adjust the spacing between the two lasing modes. This tunability of modeseparation is very promising for a range of applications requiring the generation of microwave, millimeter wave and terahertz signals. Considering the versatility and utility of such a scheme, it is imperative to acquire a deeper understanding of the factors that influence the dual-mode lasing process, in order to optimize performance. Toward this end, this paper seeks to further our understanding of the optically-injected dual-mode lasing mechanism. For fixed values of optical power injected into each FP residual mode and wavelength detuning, the dual-mode lasing characteristics are analyzed with regard to important system parameters such as the position and the intensity of the injected residual mode (relative to the Bragg and the other residual FP modes of the device) for two similarly-fabricated QD-DFBs. Results indicate that for dual mode lasing spaced less than 5 nm apart, the relative intensity of the injected FP mode and intracavity noise levels are critical factors in determining dual mode lasing behavior. Insight into the dual-mode lasing characteristics could provide an important design guideline for the master and QD-DFB slave laser cavities.

  2. Comparison of posterior internal anal sphincter myectomy and intrasphincteric botulinum toxin injection for treatment of internal anal sphincter achalasia: a meta-analysis.

    Science.gov (United States)

    Friedmacher, Florian; Puri, Prem

    2012-08-01

    Internal anal sphincter (IAS) achalasia is a clinical condition with presentation similar to Hirschsprung's disease, but with the presence of ganglion cells on rectal suction biopsy (RSB). The diagnosis is made by anorectal manometry (ARM), which demonstrates the absence of the rectosphincteric reflex on rectal balloon inflation. The recommended treatment of choice is posterior IAS myectomy. Recently, intrasphincteric botulinum toxin (Botox) injection has been effectively used for treatment of IAS achalasia. The aim of this meta-analysis was to compare the efficacy of posterior IAS myectomy with intrasphincteric Botox injection for treatment of IAS achalasia. A systematic literature search for relevant articles was conducted using the following databases: MEDLINE( ® ), EMBASE(®), ISI Web of Science(SM) and the Cochrane Library. A meta-analysis was performed with the studies where IAS achalasia was diagnosed based on the results of ARM and RSB. Odds ratio (OR) with 95 % confidence intervals were calculated. Sixteen prospective and retrospective studies, published from 1973 to 2009, were identified. A total of 395 patients with IAS achalasia were included in this meta-analysis. Fifty-eight percent of patients underwent IAS myectomy and 42 % Botox injection. Regular bowel movements were significantly more frequent after IAS myectomy (OR 0.53, [95 % CI 0.29-0.99]; p = 0.04). There was no significant difference in continued use of laxatives or rectal enemas (OR 0.92, [95 % CI 0.34-2.53], p = 0.89) and in overall complication rates between both procedures (OR 0.68, [95 % CI 0.38-1.21]; p = 0.19). Looking at specific complications, the rate of transient faecal incontinence was significantly higher after Botox injection (OR 0.07, [95 % CI 0.01-0.54]; p IAS myectomy (OR 0.56, [95 % CI 0.32-0.97]; p = 0.04 and OR 0.25, [95 % CI 0.15-0.41]; p IAS achalasia, posterior IAS myectomy appears to be a more effective treatment option compared to intrasphincteric

  3. Epidural injections with or without steroids in managing chronic low back pain secondary to lumbar spinal stenosis: a meta-analysis of 13 randomized controlled trials

    Directory of Open Access Journals (Sweden)

    Meng H

    2015-08-01

    Full Text Available Hai Meng, Qi Fei, Bingqiang Wang, Yong Yang, Dong Li, Jinjun Li, Nan Su Department of Orthopedics, Beijing Friendship Hospital, Capital Medical University, Beijing, People’s Republic of China Background: Epidural injections of anesthetic with or without steroids are widely used for treating lumbar spinal stenosis, a common cause of chronic low back pain, but there is a lack of rigorous data comparing the effectiveness of epidural injections of anesthetic with and without steroids. This meta-analysis presents a current, comprehensive picture of how epidural injections of anesthetic with steroids compare with those using local anesthetic alone.Methods: PubMed, Embase, Web of Science, and Cochrane Library databases were searched from their inception through February 5, 2015. Weight mean difference, risk ratio, and 95% confidence intervals were calculated. A random effects model or fixed effects model was used to pool the estimates, according to the heterogeneity between the included studies.Results: We included 13 randomized controlled trials, involving 1,465 patients. Significant pain relief (≥50% was demonstrated in 53.7% of patients administered with epidural injections of anesthetic with steroids (group 1 and in 56.4% of those administered with local anesthetic alone (group 2. Patients showed a reduction in numeric rating scale pain score of 3.7 and 3.6 in the two groups, respectively. Significant functional improvement was achieved in 65.2% of patients in group 1 and 63.1% of patients in group 2, with Oswestry Disability Index reductions of 13.8 and 14.5 points, respectively. The overall number of injections per year was 3.2±1.3 and 3.4±1.2 with average total relief per year of 29.3±19.7 and 33.8±19.3 weeks, respectively. The opioid intakes decreased from baseline by 12.4 and 7.8 mg, respectively. Among the outcomes listed, only total relief time differed significantly between the two groups.Conclusion: Both epidural injections with

  4. Behaviour analysis of the fuel injected in the intake manifold of port-injected spark ignition engines: modeling and experimental validation; Analyse du comportement du carburant injecte dans les conduits d`admission des moteurs a allumage commande a injection multipoint: modelisation et validation experimentale

    Energy Technology Data Exchange (ETDEWEB)

    Sches, C

    1999-01-27

    In order to limit pollutant emissions resulting from transient engine operation, the mastering of mixture formation is essential. In this context, an interactive work was undertaken between a modeling job and an experimental study, to get better understanding of the mechanisms of fuel dynamic behavior in the intake manifold of port-injected spark-ignition engines. The experimental study, elaborated thanks to experimental designs, showed out two essential factors: injection timing and coolant liquid temperature, which act on the fuel dynamic behavior through a second order filter. Then, a phenomenological modeling was established and validated, to analyze the various phenomena influencing mixture formation and to calculate the air/fuel ratio evolutions during transient operation. This program uses the results of a 3D model describing the fuel spray transportation, evaporation and impact on the port walls. The calculation does not need any boundary conditions and the running times are vary satisfactory. We showed that a correct description of the liquid fuel film was necessary to get good prediction of the mixture fuel/air ratio. The spray modeling, which is necessary, can however be kept simple. Future work may develop either in the engine control filed (injection strategies development, optimization of the injection system configuration, ...), or in the theoretical field (better modeling of fuel film displacement or of secondary atomization of the fuel on the intake valve). (author) 79 refs.

  5. Three-dimensional analysis of internal flow characteristics in the injection nozzle tip of direct-injection diesel engines; Sanjigen suchi kaiseki ni yoru DI diesel kikan no nenryo funsha nozzle nai ryudo tokusei no kaimei

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, H; Matsui, Y; Kimura, S [Nissan Motor Co. Ltd. Tokyo (Japan)

    1997-10-01

    To reduce the exhaust emissions and fuel consumption of direct-injection diesel engines, it is essential to optimize the fuel injection equipment closely related to combustion and emission characteristics. In this study, three-dimensional computation has been applied to investigate the effects of the injection nozzle specifications (e.g., sac volume, round shape at the inlet of the nozzle hole) and needle tip deviation on internal flow characteristics. The computational results revealed that the effects of the nozzle specifications and needle tip deviation with a smaller needle lift on internal flow characteristics and a general approach to optimize the injection nozzle specifications were obtained. 3 refs., 10 figs., 1 tab.

  6. Do intra-articular hyaluronic acid injections delay total knee replacement in patients with osteoarthritis - A Cox model analysis.

    Science.gov (United States)

    Delbarre, Angélique; Amor, Bernard; Bardoulat, Isabelle; Tetafort, Aymeric; Pelletier-Fleury, Nathalie

    2017-01-01

    This study aimed to describe patients treated for knee osteoarthritis between 2006 and 2013 in France and to compare the delay from diagnosis to total knee replacement between patients who received intra-articular hyaluronic acid injections and those who did not receive the injections. A second objective was to compare direct medical costs for ambulatory care between treatment groups. Patients were selected from a representative sample of the real world administrative claims database using an algorithm developed by experts from the scientific committee of the study. Data were matched with the medico-administrative database for hospital care. A Cox proportional hazards model was stratified for the treatment group and adjusted for available socio-demographic and medical covariates to compare restricted mean survival times at different time points (1, 3, 5 and 7.5 years) between groups. Costs were expressed in 2013 euros. A total of 14,782 patients were treated for knee osteoarthritis (67% women; mean age = 68 years). Among this population, 1,662 patients had total knee replacement (11.2%). At each time point, restricted mean survival time without total knee replacement was significantly higher (p-valueshyaluronic acid group, from +51 to +217 days at 1 and 7.5 years, respectively. For the year preceding total knee replacement, the means for total direct medical costs were similar between groups, €744 vs €805 for treatment and control groups, respectively, (p-value = 0.104). Intra-articular injections accounted for less than 10% of the total costs. This is the first retrospective longitudinal study involving knee osteoarthritis patients using medico-administrative databases in France. The results support the effectiveness of hyaluronic acid injections in delaying total knee replacement and show that patients treated with hyaluronic acid have similar direct medical costs for ambulatory care compared to patients treated with corticosteroids only.

  7. Thermal Performance and Reliability Analysis of Single-Phase PV Inverters with Reactive Power Injection Outside Feed-In Operating Hours

    DEFF Research Database (Denmark)

    Anurag, Anup; Yang, Yongheng; Blaabjerg, Frede

    2015-01-01

    Reactive power support by photovoltaic (PV) systems is of increasingly interest, when compared to the conventional reactive power compensation devices. PV inverters can exchange reactive power with the utility grid in a decentralized manner even outside feed-in operation, especially at nights when...... there is no solar irradiance. However, reactive power injection causes additional power losses in the switching components leading to a temperature rise in the devices. Thus, this paper analyses the impact of reactive power injection by PV inverters outside feed-in operation on the thermal performance...... of their power switching components. A thermal analysis based on the mission profile (i.e., solar irradiance and ambient temperature) has been incorporated, so as to determine the additional temperature rise in the components induced by the operation outside feed-in hours. An analytical lifetime model has been...

  8. Comparison of direct injection nebulizer and desolvating microconcentric nebulizer for analysis of chlorine-, bromine- and iodine-containing compounds by reversed phase HPLC with ICP-MS detection

    DEFF Research Database (Denmark)

    Jensen, B.P.; Gammelgaard, Bente; Hansen, S.H.

    2003-01-01

    the direct injection nebulizer at flow rates of 25 and 50 mul min(-1), the influence of 0-50% methanol and 0-25% acetonitrile on the sensitivity was studied. For chlorine and bromine, the relative sensitivity decreased with increasing amounts of organic solvent. For iodine, the relative sensitivity reached...... structure. Many chlorine-, bromine-, and iodine-containing compounds were partially lost in the desolvating unit. For those chlorine- and iodine-containing compounds that were not lost, the sensitivity was independent of methanol concentration in the solvent when a 0-100% methanol gradient was applied......With the purpose of finding ways to combine micro-bore reversed phase HPLC with ICP-MS detection for analysis of drug substances containing chlorine, bromine and iodine, the suitability of a direct injection nebulizer and an Aridus desolvating microconcentric nebulizer was compared. Using...

  9. Present-day stress analysis in the St. Lawrence Lowlands from borehole breakouts and implications for Co2 injection

    Energy Technology Data Exchange (ETDEWEB)

    Konstantinovskaya, E.; Malo, M. [Institut national de la recherche scientifique, Centre Eau, Terre et Environnement (INRS-ETE), 490, de la Couronne, Quebec, G1K 9A9 (Canada)], email: Elena.Konstantinovskaya@ete.inrs.ca; Castillo, D.A.; Hughes, Baker [Reservoir Development Services, GeoMechanics, 5373 West Alabama Street, Suite 300, Houston, Texas, 77056 (United States)], email: David.Castillo@BakerHughes.com

    2011-07-01

    An essential part of reservoir-geomechanical study in the St. Lawrence Lowlands, Quebec, consists of evaluating the geomechanical response of the rock and caprock of the reservoir to different injection scenarios and the long-term storage of CO2. The first phase of this study consists of determining current stress direction. The next step consists of assessing the potential shear failure or reactivation of pre-existing faults and fracture sets caused by changes in the reservoir pressure because of CO2 injection. According to study results, the orientation of the average maximum horizontal stress direction SHmax obtained from stress-induced wellbore borehole breakouts in this area is N59 degree E plus or minus 20 degree. The wellbore breakouts in 17 wells go from 250 m to 4 km depth. A major purpose of this geomechanical study is to estimate to what extent sustainable fluid pressures for CO2 injection can be increased without causing fracturing, faulting, or reactivation of pre-existing faults. To this end, one must determine prevailing stresses (directions and magnitudes), fault geometries and rock strengths.

  10. Incidence of hypertriglyceridemia in critically ill neonates receiving lipid injectable emulsions in glass versus plastic containers: a retrospective analysis.

    Science.gov (United States)

    Martin, Camilia R; Dumas, Gregory J; Shoaie, Claire; Zheng, Zheng; Mackinnon, Brenda; Al-Aweel, Issa; Bistrian, Bruce R; Pursley, DeWayne M; Driscoll, David F

    2008-02-01

    To evaluate plasma clearance of lipid injectable emulsions packaged in either glass or plastic containers in neonates from 2 7-month periods, 1 year apart. Clinical records from June 1 to December 31, 2003 (glass [G] period) and the same months in 2004 (plastic [P] period) were assessed. Neonates who received lipid injectable emulsions were studied. Lipid container (glass vs plastic) was the independent variable. Of the 197 patients studied, 122 (G, 50/81; P, 72/116) had evaluable triglyceride (TG) levels, for an overall rate of 62%. Only birth weight (G, 1.09 +/- 0.32 kg vs P, 1.23 +/- .45 kg) and birth length (G, 36.4 +/- 3.5 cm vs P, 37.9 +/- 3.5 cm) were significantly different between the 2 groups (P = .047 and .028, respectively). There were no differences in the day of life on which lipid injection was started, the lipid dose, or the timing of TG measurements. The incidence of hypertriglyceridemia was significantly higher in the P period (G, 3/50 vs P, 19/72; P = .004). Administration of the same lipid formulation in plastic bags compared with glass containers is associated with higher rates of hypertriglyceridemia. The poorer clearance of lipids could be due to a higher proportion of large-diameter fat globules in plastic bags compared with those in glass containers.

  11. Comparison of cardiovascular responses after injection of lidocaine with either clonidine or adrenaline: a two-year comparative analysis.

    Science.gov (United States)

    Dandriyal, R; Pachauri, S; Giri, K Y; Rastogi, S; Prasad, N I B; Agarwal, S; Singh, H P

    2017-01-01

    Our aim was to evaluate the efficacy of clonidine with lidocaine as a local anaesthetic agent for inferior alveolar mandibular nerve blocks for dental extraction. We studied 200 patients who required extraction of mandibular teeth and divided them into two groups of 100 each, the first of which was given lidocaine and adrenaline (12.5μg/ml) and the second lidocaine and clonidine (15μg/ml). Cardiovascular vascular variables (blood pressure, heart rate, and mean arterial pressure) were assessed before, during, and after extraction, and postoperative pain was measured on a visual analogue scale. There was a significant reduction in systolic blood pressure (p=0.0001) and heart rate (p=0.000) after injection of clonidine. However, they both increased after injections of lidocaine plus adrenaline, and there was a significant reduction in pain at four hours postoperatively with clonidine (p=0.000). Our results showed that anaesthesia with lidocaine and clonidine decreases systolic blood pressure and heart rate 10minutes after injection for extraction of lower mandibular teeth. We suggest that patients who have local anaesthetic with lidocaine and clonidine are at minimal cardiovascular risk and there is no difference in the onset of anaesthesia. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Image processing analysis of combustion for D. I. diesel engine with high pressure fuel injection. ; Effects of air swirl and injection pressure. Nensho shashin no gazo shori ni yoru koatsu funsha diesel kikan no nensho kaiseki. ; Swirl oyobi funsha atsuryoku no eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, I. (Japan Automobile Research Institute, Inc., Tsukuba (Japan)); Tsujimura, K.

    1994-02-25

    This paper reports an image processing analysis of combustion for a high-pressure direct injection diesel engine on the effects of air swirl and injection pressure upon combustion in the diesel engine. The paper summarizes a method to derive gas flow and turbulence strengths, and turbulent flow mixing velocity. The method derives these parameters by detecting movement of brightness unevenness on two flame photographs through utilizing the mutual correlative coefficients of image concentrations. Five types of combustion systems having different injection pressures, injection devices, and swirl ratios were used for the experiment. The result may be summarized as follows: variation in the average value of the turbulent flow mixing velocities due to difference in the swirl ratio is small in the initial phase of diffusion combustion; the difference is smaller in the case of high swirl ratio than in the case of low swirl ratio after the latter stage of the injection; the average value is larger with the higher the injection pressure during the initial stage of the combustion; after termination of the injection, the value is larger in the low pressure injection; and these trends agree with the trend in the time-based change in heat generation rates measured simultaneously. 6 refs., 14 figs., 2 tabs.

  13. Analysis of urinary neurotransmitters by capillary electrophoresis: Sensitivity enhancement using field-amplified sample injection and molecular imprinted polymer solid phase extraction

    International Nuclear Information System (INIS)

    Claude, Berengere; Nehme, Reine; Morin, Philippe

    2011-01-01

    Highlights: → Field-amplified sample injection (FASI) improves the sensitivity of capillary electrophoresis through the online pre-concentration samples. → The cationic analytes are stacked at the capillary inlet between a zone of low conductivity - sample and pre-injection plug - and a zone of high conductivity - running buffer. → The limits of quantification are 500 times lower than those obtained with hydrodynamic injection. → The presence of salts in the matrix greatly reduces the sensitivity of the FASI/CE-UV method. - Abstract: Capillary electrophoresis (CE) has been investigated for the analysis of some neurotransmitters, dopamine (DA), 3-methoxytyramine (3-MT) and serotonin (5-hydroxytryptamine, 5-HT) at nanomolar concentrations in urine. Field-amplified sample injection (FASI) has been used to improve the sensitivity through the online pre-concentration samples. The cationic analytes were stacked at the capillary inlet between a zone of low conductivity - sample and pre-injection plug - and a zone of high conductivity - running buffer. Several FASI parameters have been optimized (ionic strength of the running buffer, concentration of the sample protonation agent, composition of the sample solvent and nature of the pre-injection plug). Best results were obtained using H 3 PO 4 -LiOH (pH 4, ionic strength of 80 mmol L -1 ) as running buffer, 100 μmol L -1 of H 3 PO 4 in methanol-water 90/10 (v/v) as sample solvent and 100 μmol L -1 of H 3 PO 4 in water for the pre-injection plug. In these conditions, the linearity was verified in the 50-300 nmol L -1 concentration range for DA, 3-MT and 5-HT with a determination coefficient (r 2 ) higher than 0.99. The limits of quantification (10 nmol L -1 for DA and 3-MT, 5.9 nmol L -1 for 5-HT) were 500 times lower than those obtained with hydrodynamic injection. However, if this method is applied to the analysis of neurotransmitters in urine, the presence of salts in the matrix greatly reduces the sensitivity

  14. Analysis of urinary neurotransmitters by capillary electrophoresis: Sensitivity enhancement using field-amplified sample injection and molecular imprinted polymer solid phase extraction

    Energy Technology Data Exchange (ETDEWEB)

    Claude, Berengere, E-mail: berengere.claude@univ-orleans.fr [Institut de Chimie Organique et Analytique, CNRS FR 2708 UMR 6005, Universite d' Orleans, 45067 Orleans (France); Nehme, Reine; Morin, Philippe [Institut de Chimie Organique et Analytique, CNRS FR 2708 UMR 6005, Universite d' Orleans, 45067 Orleans (France)

    2011-08-12

    Highlights: {yields} Field-amplified sample injection (FASI) improves the sensitivity of capillary electrophoresis through the online pre-concentration samples. {yields} The cationic analytes are stacked at the capillary inlet between a zone of low conductivity - sample and pre-injection plug - and a zone of high conductivity - running buffer. {yields} The limits of quantification are 500 times lower than those obtained with hydrodynamic injection. {yields} The presence of salts in the matrix greatly reduces the sensitivity of the FASI/CE-UV method. - Abstract: Capillary electrophoresis (CE) has been investigated for the analysis of some neurotransmitters, dopamine (DA), 3-methoxytyramine (3-MT) and serotonin (5-hydroxytryptamine, 5-HT) at nanomolar concentrations in urine. Field-amplified sample injection (FASI) has been used to improve the sensitivity through the online pre-concentration samples. The cationic analytes were stacked at the capillary inlet between a zone of low conductivity - sample and pre-injection plug - and a zone of high conductivity - running buffer. Several FASI parameters have been optimized (ionic strength of the running buffer, concentration of the sample protonation agent, composition of the sample solvent and nature of the pre-injection plug). Best results were obtained using H{sub 3}PO{sub 4}-LiOH (pH 4, ionic strength of 80 mmol L{sup -1}) as running buffer, 100 {mu}mol L{sup -1} of H{sub 3}PO{sub 4} in methanol-water 90/10 (v/v) as sample solvent and 100 {mu}mol L{sup -1} of H{sub 3}PO{sub 4} in water for the pre-injection plug. In these conditions, the linearity was verified in the 50-300 nmol L{sup -1} concentration range for DA, 3-MT and 5-HT with a determination coefficient (r{sup 2}) higher than 0.99. The limits of quantification (10 nmol L{sup -1} for DA and 3-MT, 5.9 nmol L{sup -1} for 5-HT) were 500 times lower than those obtained with hydrodynamic injection. However, if this method is applied to the analysis of

  15. Fast batch injection analysis of H{sub 2}O{sub 2} using an array of Pt-modified gold microelectrodes obtained from split electronic chips

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, Bruno D.; Valerio, Jaqueline [Centro de Ciencias e Humanidades - Universidade Presbiteriana Mackenzie, Rua da Consolacao, 896, 01302-907 Sao Paulo, SP (Brazil); Angnes, Lucio [Departamento de Quimica Fundamental, Instituto de Quimica da USP, Av. Prof. Lineu Prestes, 748, 05508-000 Cidade Universitaria, Sao Paulo, SP (Brazil); Pedrotti, Jairo J., E-mail: jpedrotti@mackenzie.br [Centro de Ciencias e Humanidades - Universidade Presbiteriana Mackenzie, Rua da Consolacao, 896, 01302-907 Sao Paulo, SP (Brazil)

    2011-06-24

    Graphical abstract: Highlights: > An array of gold microelectrodes modified with Pt was used for batch injection analysis of H{sub 2}O{sub 2} in rainwater. > The microelectrode array (n = 14) was obtained from electronic chips developed for surface mounted device technology. > The analytical frequency of the method can attain 300 determinations per hour. > The volume-weighted mean concentration of H{sub 2}O{sub 2} in rainwater investigated (n = 25) was 14.2 {mu}mol L{sup -1}. - Abstract: A fast and robust analytical method for amperometric determination of hydrogen peroxide (H{sub 2}O{sub 2}) based on batch injection analysis (BIA) on an array of gold microelectrodes modified with platinum is proposed. The gold microelectrode array (n = 14) was obtained from electronic chips developed for surface mounted device technology (SMD), whose size offers advantages to adapt them in batch cells. The effect of the dispensing rate, volume injected, distance between the platinum microelectrodes and the pipette tip, as well as the volume of solution in the cell on the analytical response were evaluated. The method allows the H{sub 2}O{sub 2} amperometric determination in the concentration range from 0.8 {mu}mol L{sup -1} to 100 {mu}mol L{sup -1}. The analytical frequency can attain 300 determinations per hour and the detection limit was estimated in 0.34 {mu}mol L{sup -1} (3{sigma}). The anodic current peaks obtained after a series of 23 successive injections of 50 {mu}L of 25 {mu}mol L{sup -1} H{sub 2}O{sub 2} showed an RSD < 0.9%. To ensure the good selectivity to detect H{sub 2}O{sub 2}, its determination was performed in a differential mode, with selective destruction of the H{sub 2}O{sub 2} with catalase in 10 mmol L{sup -1} phosphate buffer solution. Practical application of the analytical procedure involved H{sub 2}O{sub 2} determination in rainwater of Sao Paulo City. A comparison of the results obtained by the proposed amperometric method with another one which

  16. Efficacy and safety of adjuvant intravitreal injection of anti-vascular endothelial growth factors prior to vitrectomy in the treatment of proliferative diabetic retinopathy: A Meta-analysis

    Directory of Open Access Journals (Sweden)

    Jun Li

    2017-08-01

    Full Text Available AIM: To investigate the effectiveness and safety of intravitreal injection of anti-vascular endothelial growth factors(VEGFdrugs to the patients with proliferative diabetic retinopathy before vitrectomy treatment.METHODS: A Meta-analysis. A comprehensive retrieval was conducted using the database including EMbase, the Cochrane Library, Pubmed, CBM, WanFang Database, CNKI and so on. The retrieval time was limited from the building time of database to Jan. 2017. The randomized controlled trial was adopted with no requirements on languages. The Jadad scale and Cochrance cooperation were used as the tool of the risk and bias evaluation to analyze the literature quality. Quality estimation of evidence-based medicine on the parameters of each evaluation index was made via GRADEpro Software. The publishing biases of enclosed documents were inspected with funnel plot. At last, the Meta analysis was conducted with Review Manager 5.3.RESULTS: Totally 16 literatures published from 2008-2016 were finally put into randomized controlled trial. A total of 923 cases were included, among which 493 cases were grouped as intravitreal injection of anti-VEGF before the combined operation of PPV group(the experimental group, and 430 cases were involved in simple PPV group(the control group. The results of Meta-analysis show:(1The probability of intraoperative bleeding was remarkably lower than the control group \\〖OR=0.06, 95%CI(0.02, 0.15, PWMD=-29.13, 95% CI(-36.95, -21.30, POR=0.34, 95%CI(0.20, 0.58, PWMD=-0.51(LogMAR, 95%CI(-1.10, 0.08, P=0.09\\〗 with no statistical significance.(5The occurrence of iatrogenic retinal rupture was lower than that of the control group\\〖OR=0.24, 95%CI(0.14, 0.40, PCONCLUSION: It is effective and safe for the patients with proliferative diabetic retinopathy to inject anti-VEGF drugs into vitreous cavity before vitrectomy. And it can reduce the occurrence of complications during and after surgery, improving the general treatment

  17. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... sures regarding disposable injection equipment, waste containers, hand hygiene ... injection practices lead to high prevalence of NSSIs in operating rooms. .... guidelines, the availability of training courses to HCWs, and provi-.

  18. Analysis of the Electrical Properties of an Electron Injection Layer in Alq3-Based Organic Light Emitting Diodes.

    Science.gov (United States)

    Kim, Soonkon; Choi, Pyungho; Kim, Sangsub; Park, Hyoungsun; Baek, Dohyun; Kim, Sangsoo; Choi, Byoungdeog

    2016-05-01

    We investigated the carrier transfer and luminescence characteristics of organic light emitting diodes (OLEDs) with structure ITO/HAT-CN/NPB/Alq3/Al, ITO/HAT-CN/NPB/Alq3/Liq/Al, and ITO/HAT-CN/NPB/Alq3/LiF/A. The performance of the OLED device is improved by inserting an electron injection layer (EIL), which induces lowering of the electron injection barrier. We also investigated the electrical transport behaviors of p-Si/Alq3/Al, p-Si/Alq3/Liq/Al, and p-Si/Alq3/LiF/Al Schottky diodes, by using current-voltage (L-V) and capacitance-voltage (C-V) characterization methods. The parameters of diode quality factor n and barrier height φ(b) were dependent on the interlayer materials between Alq3 and Al. The barrier heights φ(b) were 0.59, 0.49, and 0.45 eV, respectively, and the diode quality factors n were 1.34, 1.31, and 1.30, respectively, obtained from the I-V characteristics. The built in potentials V(bi) were 0.41, 0.42, and 0.42 eV, respectively, obtained from the C-V characteristics. In this experiment, Liq and LiF thin film layers improved the carrier transport behaviors by increasing electron injection from Al to Alq3, and the LiF schottky diode showed better I-V performance than the Liq schottky diode. We confirmed that a Liq or LiF thin film inter-layer governs electron and hole transport at the Al/Alq3 interface, and has an important role in determining the electrical properties of OLED devices.

  19. Intrastriatal injection of botulinum neurotoxin-A is not cytotoxic in rat brain - A histological and stereological analysis.

    Science.gov (United States)

    Mehlan, Juliane; Brosig, Hans; Schmitt, Oliver; Mix, Eilhard; Wree, Andreas; Hawlitschka, Alexander

    2016-01-01

    Parkinson's disease (PD) is caused by progressive degeneration of dopaminergic neurons in the substantia nigra pars compacta, resulting in a deficiency of dopamine in the striatum and an increased release of acetylcholine by tonically active interneurons. Botulinum neurotoxin-A (BoNT-A) is well known for blocking transmitter release by cholinergic presynaptic terminals. Treating striatal hypercholinism by local application of BoNT-A could be a possible new local therapy option of PD. In previous studies of our group, we analyzed the effect of BoNT-A injection into the CPu of 6-OHDA lesioned hemiparkinsonian rats. Our studies showed that BoNT-A application in hemiparkinson rat model is capable of abolishing apomorphine induced rotations for approximately 3 months. Regularly occurring axonal swellings in the BoNT-A infiltrated striata were also discovered, which we named BoNT-A induced varicosities (BiVs). Résumé: Here we investigated the long-term effect of the injection of 1ng BoNT-A into the right CPu of naive Wistar rats on the number of ChAT-ir interneurons as well as on the numeric density and the volumetric size of the BiVs in the CPu. Significant differences in the number of ChAT-ir neurons between the right BoNT-A treated CPu and the left untreated CPu were not detected up to 12 month post BoNT-A injection. The numeric density of BiVs in the treated CPu reached a maximum 3 months after BoNT-A treatment and decreased afterwards, whereas the volume of single BiVs increased steadily throughout the whole time course of the experiment. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Electrokinetic gated injection-based microfluidic system for quantitative analysis of hydrogen peroxide in individual HepG2 cells.

    Science.gov (United States)

    Zhang, Xinyuan; Li, Qingling; Chen, Zhenzhen; Li, Hongmin; Xu, Kehua; Zhang, Lisheng; Tang, Bo

    2011-03-21

    A microfluidic system to determine hydrogen peroxide (H(2)O(2)) in individual HepG2 cells based on the electrokinetic gated injection was developed for the first time. A home-synthesized fluorescent probe, bis(p-methylbenzenesulfonate)dichlorofluorescein (FS), was employed to label intracellular H(2)O(2) in the intact cells. On a simple cross microchip, multiple single-cell operations, including single cell injection, cytolysis, electrophoresis separation and detection of H(2)O(2), were automatically carried out within 60 s using the electrokinetic gated injection and laser-induced fluorescence detection (LIFD). The performance of the method was evaluated under the optimal conditions. The linear calibration curve was over a range of 4.39-610 amol (R(2)=0.9994). The detection limit was 0.55 amol or 9.0×10(-10) M (S/N=3). The relative standard deviations (RSDs, n=6) of migration time and peak area were 1.4% and 4.8%, respectively. With the use of this method, the average content of H(2)O(2) in single HepG2 cells was found to be 16.09±9.84 amol (n=15). Separation efficiencies in excess of 17,000 theoretical plates for the cells were achieved. These results demonstrated that the efficient integration and automation of these single-cell operations enabled the sensitive, reproducible, and quantitative examination of intracellular H(2)O(2) at single-cell level. Owing to the advantages of simple microchip structure, controllable single-cell manipulation and ease in building, this platform provides a universal way to automatically determine other intracellular constituents within single cells. This journal is © The Royal Society of Chemistry 2011

  1. Determination of dasatinib in the tablet dosage form by ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis.

    Science.gov (United States)

    Gonzalez, Aroa Garcia; Taraba, Lukáš; Hraníček, Jakub; Kozlík, Petr; Coufal, Pavel

    2017-01-01

    Dasatinib is a novel oral prescription drug proposed for treating adult patients with chronic myeloid leukemia. Three analytical methods, namely ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis, were developed, validated, and compared for determination of the drug in the tablet dosage form. The total analysis time of optimized ultra high performance liquid chromatography and capillary zone electrophoresis methods was 2.0 and 2.2 min, respectively. Direct ultraviolet detection with detection wavelength of 322 nm was employed in both cases. The optimized sequential injection analysis method was based on spectrophotometric detection of dasatinib after a simple colorimetric reaction with folin ciocalteau reagent forming a blue-colored complex with an absorbance maximum at 745 nm. The total analysis time was 2.5 min. The ultra high performance liquid chromatography method provided the lowest detection and quantitation limits and the most precise and accurate results. All three newly developed methods were demonstrated to be specific, linear, sensitive, precise, and accurate, providing results satisfactorily meeting the requirements of the pharmaceutical industry, and can be employed for the routine determination of the active pharmaceutical ingredient in the tablet dosage form. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Do intra-articular hyaluronic acid injections delay total knee replacement in patients with osteoarthritis – A Cox model analysis

    Science.gov (United States)

    Amor, Bernard; Bardoulat, Isabelle; Tetafort, Aymeric; Pelletier-Fleury, Nathalie

    2017-01-01

    Due to the growing worldwide prevalence of knee osteoarthritis, the optimal management of this issue is critical for reducing its burden. Objectives This study aimed to describe patients treated for knee osteoarthritis between 2006 and 2013 in France and to compare the delay from diagnosis to total knee replacement between patients who received intra-articular hyaluronic acid injections and those who did not receive the injections. A second objective was to compare direct medical costs for ambulatory care between treatment groups. Materials and methods Patients were selected from a representative sample of the real world administrative claims database using an algorithm developed by experts from the scientific committee of the study. Data were matched with the medico-administrative database for hospital care. A Cox proportional hazards model was stratified for the treatment group and adjusted for available socio-demographic and medical covariates to compare restricted mean survival times at different time points (1, 3, 5 and 7.5 years) between groups. Costs were expressed in 2013 euros. Results A total of 14,782 patients were treated for knee osteoarthritis (67% women; mean age = 68 years). Among this population, 1,662 patients had total knee replacement (11.2%). At each time point, restricted mean survival time without total knee replacement was significantly higher (p-valueshyaluronic acid group, from +51 to +217 days at 1 and 7.5 years, respectively. For the year preceding total knee replacement, the means for total direct medical costs were similar between groups, €744 vs €805 for treatment and control groups, respectively, (p-value = 0.104). Intra-articular injections accounted for less than 10% of the total costs. Conclusion This is the first retrospective longitudinal study involving knee osteoarthritis patients using medico-administrative databases in France. The results support the effectiveness of hyaluronic acid injections in delaying total knee

  3. Two-dimensional analysis of two-phase reacting flow in a firing direct-injection diesel engine

    Science.gov (United States)

    Nguyen, H. Lee

    1989-01-01

    The flow field, spray penetration, and combustion in two-stroke diesel engines are described. Fuel injection begins at 345 degrees after top dead center (ATDC) and n-dodecane is used as the liquid fuel. Arrhenius kinetics is used to calculate the reaction rate term in the quasi-global combustion model. When the temperature, fuel, and oxygen mass fraction are within suitable flammability limits, combustion begins spontaneously. No spark is necessary to ignite a localized high temperature region. Compression is sufficient to increase the gaseous phase temperature to a point where spontaneous chemical reactions occur. Results are described for a swirl angle of 22.5 degrees.

  4. Injection Laryngoplasty Materials

    OpenAIRE

    Haldun Oðuz

    2013-01-01

    Injection laryngoplasty is one of the treatment options for voice problems. In the recent years, more safe and more biocompatible injection materials are available on the market. Long and short term injection materials are discussed in this review.

  5. Penicillin G Procaine Injection

    Science.gov (United States)

    Penicillin G procaine injection is used to treat certain infections caused by bacteria. Penicillin G procaine injection should not be used to ... early in the treatment of certain serious infections. Penicillin G procaine injection is in a class of ...

  6. FLOW INJECTION ANALYSIS SYSTEM COUPLED WITH ICP-EOS FOR DETERMINATION OF SOME METALLIC ELEMENTS IN DRINKING WATER

    Directory of Open Access Journals (Sweden)

    Cristina Dinu

    2009-06-01

    Full Text Available The European Drinking Water Directive (98/83/EC, transposed in Romanian Legislation as Low 458/2002, amended by Low 311/2004, imposes the limit of concentration for metallic elements in water intended for human consumption. The toxic metals arsenic and selenium are among these elements and the limit value is 10 μg/L. In the paper there are presented the working conditions for determination of As and Se from drinking water using modern techniques based on the fl ow injection-hydride generation with the inductively coupled plasma atomic emission spectrometry (FIAS-ICP-EOS. The analyses were performed on Optima 5300 DV Perkin Elmer equipment with FIAS 400 Flow Injection System, Perkin Elmer type. For the hydride generation two types of solution were used: 10% (v/v HCl as a carrier solution and 0.2 % NaBH4 in 0.05%NaOH solution as a reducing agent [1]. The treatment step of the samples and standard solutions consisted in reducing with mixed solutions of KI and ascorbic acid in acidic condition (HCl for As and only with HCl and high temperature for Se [2,3]. The paper contains the characteristic parameters of the methods, such as: low detection limit, quantifi cation limit, repeatability, precision, recovery, which were evaluated using Certifi ed Reference Materials for each element.

  7. Performance and combustion analysis of Mahua biodiesel on a single cylinder compression ignition engine using electronic fuel injection system

    Directory of Open Access Journals (Sweden)

    Gunasekaran Anandkumar

    2016-01-01

    Full Text Available In this investigation, experiment is carried out on a 1500 rpm constant speed single cylinder Diesel engine. The test is carried out with Neat diesel, neat biodiesel, and blend B20. The engine considered was run with electronic fuel injection system supported by common rail direct injection to obtain high atomization and effective air utilization inside the combustion chamber. The performance of the engine in terms of break thermal efficiency and brake specific energy consumption was found and compared. The B20 blend shows 1.11% decrease in break thermal efficiency and 3.35% increase in brake specific energy consumption than diesel. The combustion characteristics found are in-cylinder pressure, rate of pressure rise, and heat release rate and compared for peak pressure load to understand the nature of combustion process. For each fuel test run, the maximum peak pressure is observed at part load condition. The rate of change of pressure and heat release rate of diesel is high compared to pure biodiesel and B20 blend. The diffusion combustion is observed to be predominant in case of B100 than B20 and Neat diesel.

  8. Performance and thermal decomposition analysis of foaming agent NPL-10 for use in heavy oil recovery by steam injection

    Directory of Open Access Journals (Sweden)

    Zhao Fa-Jun

    2018-02-01

    Full Text Available Foaming agents, despite holding potential in steam injection technology for heavy oil recovery, are still poorly investigated. In this work, we analyzed the performance of the foaming agent NPL-10 in terms of foam height and half-life under various conditions of temperature, pH, salinity, and oil content by orthogonal experiments. The best conditions of use for NPL-10 among those tested are T=220°C, pH 7, salinity 10000 mg·L–1 and oil content 10 g·L–1. Thermal decomposition of NPL-10 was also studied by thermogravimetric and differential thermal analyses. NPL-10 decomposes above 220°C, and decomposition is a two-step process. The kinetic triplet (activation energy, kinetic function and pre-exponential factor and the corresponding rate law were calculated for each step. Steps 1 and 2 follow kinetics of different order (n = 2 and ½, respectively. These findings provide some criteria for the selection of foaming agents for oil recovery by steam injection.

  9. Thermographic analysis of photodynamic therapy with intense pulsed light and needle-free injection photosensitizer delivery: an animal study

    Science.gov (United States)

    Requena, Michelle B.; Stringasci, Mirian D.; Pratavieira, Sebastião.; Vollet-Filho, José Dirceu; de Nardi, Andrigo B.; Escobar, Andre; da Rocha, Rozana W.; Bagnato, Vanderlei S.; de Menezes, Priscila F. C.

    2018-02-01

    The photodynamic therapy (PDT) is a therapeutic modality that depends mostly on photosensitizer (PS), light and molecular oxygen species. However, there are still technical limitations in clinical PDT that are under constant development, particularly concerning PS and light delivery. Intense Pulsed Light (IPL) sources are systems able to generate pulses of high energy with polychromatic light. IPL is a technique mainly used in the cosmetic area to perform various skin treatments for therapeutic and aesthetic applications. The goals of this study were to determine temperature variance during the application of IPL in porcine skin model, and the PDT effects using this light source with PS delivery by a commercial high pressure, needle-free injection system. The PSs tested were Indocyanine Green (ICG) and Photodithazine (PDZ), and the results showed an increase bellow 10 °C in the skin surface using a thermographic camera to measure. In conclusion, our preliminary study demonstrated that IPL associated with needle-free injection PS delivery could be a promising alternative to PDT.

  10. Thermo-mechanical analysis of an acceleration grid for the international thermonuclear experimental reactor-neutral beam injection system

    International Nuclear Information System (INIS)

    Fujiwara, Yukio; Hanada, Masaya; Okumura, Yoshikazu; Suzuki, Satoshi; Watanabe, Kazuhiro

    2001-01-01

    In the engineering design of a negative-ion beam source for a high-power neutral beam injection (NBI) system, one of the most important issues is thermo-mechanical design of acceleration grids for producing several tens of MW ion beams. An acceleration grid for the international thermonuclear experimental reactor-neutral beam injection (ITER-NBI) system will be subjected to the heat loading as high as 1.5 MW. In the present paper, thermo-mechanical characteristics of the acceleration grid for the ITER-NBI system were analyzed. Numerical simulation indicated that maximum aperture-axis displacement of the acceleration grid due to thermal expansion would be about 0.7 mm for the heat loading of 1.5 MW. From the thin lens theory of beam optics, beamlet deflection angle by the aperture-axis displacement was estimated to be about 2 mrad, which is within the requirement of the engineering design of the ITER-NBI system. Numerical simulation also indicated that no melting on the acceleration grid would occur for a heat loading of 1.5 MW, while local plastic deformation would happen. To avoid the plastic deformation, it is necessary to reduce the heat loading onto the acceleration grid to less than 1 MW

  11. [Matrix effect and application of field-amplified sample injection in the analysis of four tetracyclines in waters by capillary electrohoresis].

    Science.gov (United States)

    2014-08-01

    The system abilities of two chromatographic techniques, capillary electrophoresis (CE) and high performance liquid chromatography (HPLC), were compared for the analysis of four tetracyclines (tetracycline, chlorotetracycline, oxytetracycline and doxycycline). The pH, concentration of background electrolyte (BGE) were optimized for the analysis of the standard mixture sample, meanwhile, the effects of separation voltage and water matrix (pH value and hardness) effects were investigated. In hydrodynamic injection (HDI) mode, a good quantitative linearity and baseline separation within 9. 0 min were obtained for the four tetracyclines at the optimal conditions; the analytical time was about half of that of HPLC. The limits of detection (LODs) were in the range of 0. 28 - 0. 62 mg/L, and the relative standard deviations (RSDs) (n= 6) of migration time and peak area were 0. 42% - 0. 56% and 2. 24% - 2. 95%, respectively. The obtained recoveries spiked in tap water and fishpond water were at the ranges of 96. 3% - 107. 2% and 87. 1% - 105. 2%, respectively. In addition, the stacking method, field-amplified sample injection (FASI), was employed to improve the sensitivity, and the LOD was down to the range of 17.8-35.5 μg/L. With FASI stacking, the RSDs (n=6) of migration time and peak area were 0. 85%-0. 95% and 1. 69%-3.43%, respectively. Due to the advantages of simple sample pretreatment and fast speed, CE is promising in the analysis of the antibiotics in environmental water.

  12. AN APPLICATION OF FLOW INJECTION ANALYSIS WITH GAS DIFFUSION AND SPECTROPHOTOMETRIC DETECTION FOR THE MONITORING OF DISSOLVED SULPHIDE CONCENTRATION IN ENVIRONMENTAL SAMPLES

    Directory of Open Access Journals (Sweden)

    Malwina Cykowska

    2014-10-01

    Full Text Available The monitoring of the concentration of sulphide is very important from the environment point of view because of high toxicity of hydrogen sulphide. What is more hydrogen sulphide is an important pollution indicator. In many cases the determination of sulphide is very difficult due to complicated matrix of some environmental samples, which causes that most analytical methods cannot be used. Flow injection analysis allows to avoid matrix problem what makes it suitable for a wide range of applications in analytical laboratories. In this paper determination of dissolved sulphide in environmental samples by gas-diffusion flow injection analysis with spectrophotometric detection was presented. Used gas-diffusion separation ensures the elimination of interferences caused by sample matrix and gives the ability of determination of sulphides in coloured and turbid samples. Studies to optimize the measurement conditions and to determine the value of the validation parameters (e.g. limit of detection, limit of quantification, precision, accuracy were carried out. Obtained results confirm the usefulness of the method for monitoring the concentration of dissolved sulphides in water and waste water. Full automation and work in a closed system greatly reduces time of analysis, minimizes consumption of sample and reagents and increases safety of analyst’s work.

  13. Gas injection test in a borehole of the Meuse/Haute Marne underground research laboratory: experimental overview and basic data analysis

    International Nuclear Information System (INIS)

    La Vaissiere, Remi de; Talandier, Jean; Piedevache, Mederic; Helmlinger, Benjamin; Lavanchy, Jean-Marc; Croise, Jean; Senger, Rainer

    2012-01-01

    Document available in extended abstract form only. Understanding of the fate and of the impact of gas produced by corrosion of metals, microbial degradation and the radiolysis of water within a deep geological disposal repository for radioactive waste, is of major relevance in the performance assessment including the long-term evolution of the repository. To address these issues, the French national Agency for the management of radioactive waste (Andra) has directed a field scale experiment examining the mechanisms controlling gas entry and gas migration in the Callovo-Oxfordian (COX) clay, the proposed host rock of the French deep geological repository project. This experiment, called PGZ1, studies the migration of nitrogen in the COX based on gas injection tests performed in a borehole of the Meuse/Haute Marne URL. This experiment is currently being performed under the auspices of the Euratom 7. Framework FORGE project. In this poster, we provide an overview on the field data and a basic analysis of the data. The advanced interpretation of the data was based on numerical modeling of the two-phase flow with 3 different approaches and numerical codes. The experimental layout consists of three boreholes. Two parallel boreholes (PGZ1201 and PGZ1202) were drilled from the GED drift and are equipped with a triple interval system to monitor the pressure evolutions in 3 intervals, associated with the hydraulic and gas injection tests in the selected test interval (PGZ1201, middle interval). The third borehole (PGZ1031) was drilled from the GEX drift and is equipped with an extensometer probe, to monitor potential deformation associated with the resulting stress changes. An initial hydraulic test (HYDRO1) was performed in the test interval to estimate the hydraulic conductivity of the COX prior to gas testing. The hydraulic test consisted in a sequence of injections of synthetic formation water (pressure pulse followed by a constant pressure and a final shut-in phase

  14. Which are the best Chinese herbal injections combined with XELOX regimen for gastric cancer?: A PRISMA-compliant network meta-analysis.

    Science.gov (United States)

    Zhang, Dan; Wu, Jiarui; Wang, Kaihuan; Duan, Xiaojiao; Liu, Shi; Zhang, Bing

    2018-03-01

    The optimal Chinese herbal injections (CHIs) combined with XELOX regimen for patients with gastric cancer remains elusive. The aim of our network meta-analysis (NMA) is to explore the best options among different CHIs for gastric cancer. PubMed, Embase, the Cochrane Library, the China National Knowledge Infrastructure Database (CNKI), Wan-fang Database, Cqvip Database (VIP), China Biology Medicine disc (CBMdisc) were searched to identify RCTs which focused on CHIs against gastric cancer. The quality assessment of included randomized controlled trials (RCTs) was conducted by the Cochrane risk of bias tool. Standard pair-wise and Bayesian NMAs were performed to compare the efficacy and safety of different CHIs combined with the XELOX regimen via Stata 13.0 and WinBUGS1.4 software. A total of 2316 records were searched, the network of evidence included 26 eligible RCTs involving 13 types of CHIs and 2154 patients. The results suggested that Shenqifuzheng+ XELOX, Huachansu+ XELOX, Kangai+ XELOX, Javanica oil emulsion+ XELOX, Aidi injection+ XELOX might be the optimal treatment for gastric cancer in improving the performance status than using XELOX regimen single, with odds ratios (OR) and 95% confidence intervals (CIs) of 2.74 (1.24, 6.17), 8.27 (1.74, 42.43), 4.28 (1.80, 10.48), 5.14 (1.87, 16.28), 0.20 (0.090, 0.44). At the aspects of ADRs (adverse reactions), Compound Kushen+ XELOX, Lentinan+ XELOX, Xiaoaiping injection+ XELOX could obviously relieve leukopenia than only receiving XELOX regimen, and their ORs and 95% CIs were 5.62 (1.41, 36.24), 8.16 (2.25, 29.43), 5.69 (1.85, 15.77). Furthermore, Disodium cantharidinate and vitamin B6+ XELOX, Shenqifuzheng+ XELOX, Kangai+ XELOX, Lentinan+ XELOX could obviously relieve the nausea and vomiting than receiving the XELOX regimen alone, with ORs and 95% CIs of 5.29 (1.30, 23.96), 2.50 (1.16, 5.26), 2.42 (1.06, 5.63), 9.04 (3.24, 26.73). Nevertheless, CHIs combined with XELOX regimen did not confer higher better clinical

  15. Flow-injection analysis of nitrate by reduction to nitrite and gas-phase molecular absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Haghighi, B.; Tavassoli, A. [Dept. of Chemistry, Inst. for Advanced Studies in Basic Sciences, Zanjan (Iran)

    2001-12-01

    Two flow-injection manifolds have been investigated for the determination of nitrate. These manifolds are based on the reduction of nitrate to nitrite and determination of nitrite by gas-phase molecular absorption spectrophotometry. Nitrate sample solution (300 {mu}L) which is injected to the flow line, is reduced to nitrite by reaction with hydrazine or passage through the on-line copperized cadmium (Cd-Cu) reduction column. The nitrite produced reacts with a stream of hydrochloric acid and the evolved gases are purged into the stream of O{sub 2}carrier gas. The gaseous phase is separated from the liquid phase using a gas-liquid separator and then swept into a flow-through cell which has been positioned in the cell compartment of an UV-visible spectrophotometer. The absorbance of the gaseous phase is measured at 204.7 nm. A linear relationship was obtained between the intensity of absorption signals and concentration of nitrate when Cd-Cu reduction method was used, but a logarithmic relationship was obtained when the hydrazine reduction method was used. By use of the Cd-Cu reduction method, up to 330 {mu}g of nitrate was determined. The limit of detection was 2.97 {mu}g nitrate and the relative standard deviations for the determination of 12.0, 30.0 and 150 {mu}g nitrate were 3.32, 3.87 and 3.6%, respectively. Maximum sampling rate was approximately 30 samples per hour. The Cd-Cu reduction method was applied to the determination of nitrate and the simultaneous determination of nitrate and nitrite in meat products, vegetables, urine, and a water sample. (orig.)

  16. Construction and performance characterization of ion-selective electrodes for potentiometric determination of pseudoephedrine hydrochloride applying batch and flow injection analysis techniques.

    Science.gov (United States)

    Zayed, Sayed I M; Issa, Yousry M; Hussein, Ahmed

    2006-01-01

    New pseudoephedrine selective electrodes have been constructed of the conventional polymer membrane type by incorporation of pseudoephedrine-phosphotungstate (PE-PT) or pseudoephedrine-silicotungstate (PE-SiT) ion-associates in a poly vinyl chloride (PVC) membrane plasticized with dibutyl phthalate (DBP). The electrodes were fully characterized in terms of the membrane composition, temperature, and pH. The electrodes exhibited mean slopes of calibration graphs of 57.09 and 56.10 mV concentration decade(-1) of PECl at 25 degrees C for (PE-PT) and (PE-SiT) electrodes, respectively. The electrodes showed fast, stable, and near-Nernstian response over the concentration ranges 6.31 x 10(-6)-1.00 x 10(-2) and 5.00 x 10(-5)-1.00x10(-2) M in the case of PE-PT applying batch and flow injection (FI) analysis, respectively, and 1.00 x 10(-5)-1.00 x 10(-2) and 5.00 x 10(-5)-1.00x10(-2) M in the case of PE-SiT for batch and FI analysis system, respectively. Detection limit was 5.01x 10(-6) M for PE-PT electrode and 6.31x10(-6) M for PE-SiT electrode. The electrodes were successfully applied for the potentiometric determination of pseudoephedrine hydrochloride (PECl) in pharmaceutical preparations with mean recovery 101.13 +/- 0.85% and 100.77+0.79% in case of PE-PT applying batch and flow injection systems, respectively, and 100.75+0.85% and 100.79 +/- 0.77% in case of PE-SiT for batch and flow injection systems, respectively. The electrodes exhibited good selectivity for PECl with respect to a large number of inorganic cations, sugars and amino acids.

  17. Quantitative analysis of fragrance in selectable one dimensional or two dimensional gas chromatography-mass spectrometry with simultaneous detection of multiple detectors in single injection.

    Science.gov (United States)

    Tan, Hui Peng; Wan, Tow Shi; Min, Christina Liew Shu; Osborne, Murray; Ng, Khim Hui

    2014-03-14

    A selectable one-dimensional ((1)D) or two-dimensional ((2)D) gas chromatography-mass spectrometry (GC-MS) system coupled with flame ionization detector (FID) and olfactory detection port (ODP) was employed in this study to analyze perfume oil and fragrance in shower gel. A split/splitless (SSL) injector and a programmable temperature vaporization (PTV) injector are connected via a 2-way splitter of capillary flow technology (CFT) in this selectable (1)D/(2)D GC-MS/FID/ODP system to facilitate liquid sample injections and thermal desorption (TD) for stir bar sorptive extraction (SBSE) technique, respectively. The dual-linked injectors set-up enable the use of two different injector ports (one at a time) in single sequence run without having to relocate the (1)D capillary column from one inlet to another. Target analytes were separated in (1)D GC-MS/FID/ODP and followed by further separation of co-elution mixture from (1)D in (2)D GC-MS/FID/ODP in single injection without any instrumental reconfiguration. A (1)D/(2)D quantitative analysis method was developed and validated for its repeatability - tR; calculated linear retention indices (LRI); response ratio in both MS and FID signal, limit of detection (LOD), limit of quantitation (LOQ), as well as linearity over a concentration range. The method was successfully applied in quantitative analysis of perfume solution at different concentration level (RSD≤0.01%, n=5) and shower gel spiked with perfume at different dosages (RSD≤0.04%, n=5) with good recovery (96-103% for SSL injection; 94-107% for stir bar sorptive extraction-thermal desorption (SBSE-TD). Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Immersed single-drop microextraction interfaced with sequential injection analysis for determination of Cr(VI) in natural waters by electrothermal-atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Pena, Francisco; Lavilla, Isela; Bendicho, Carlos

    2008-01-01

    Single-drop microextraction (SDME) and sequential injection analysis have been hyphenated for ultratrace metal determination by Electrothermal-Atomic Absorption Spectrometry (ETAAS). The novel method was targeted on extraction of the Cr(VI)-APDC chelate and encompasses the potential of SDME as a miniaturized and virtually solvent-free preconcentration technique, the ability of sequential injection analysis to handle samples and the versatility of furnace autosamplers for introducing microliter samples in ETAAS. The variables influencing the microextraction of Cr(VI) onto an organic solvent drop, i.e., type of organic solvent, microextraction time, stirring rate of the sample solution, drop volume, immersion depth of the drop, salting-out effect, temperature of the sample, concentration of the complexing agent and pH of the sample solution were fully investigated. For a 5 and 20 min microextraction time, the preconcentration factors were 20 and 70, respectively. The detection limit was 0.02 μg/L of Cr(VI) and the repeatability expressed as relative standard deviation was 7%. The SDME-SIA-ETAAS technique was validated against BCR CRM 544 (lyophilized solution) and applied to ultrasensitive determination of Cr(VI) in natural waters

  19. Three or more preoperative injections is the most significant risk factor for revision surgery after operative treatment of lateral epicondylitis: an analysis of 3863 patients.

    Science.gov (United States)

    Degen, Ryan M; Cancienne, Jourdan M; Camp, Christopher L; Altchek, David W; Dines, Joshua S; Werner, Brian C

    2017-04-01

    This study was conducted to identify the rate of failure of operative treatment of lateral epicondylitis, defined as progression to ipsilateral revision surgery, and associated patient-specific risk factors for failure. A national database was used to identify patients undergoing surgical treatment of lateral epicondylitis from 2005 to 2012. Patients undergoing concomitant procedures were excluded. Patients who then required subsequent ipsilateral extensor carpi radialis brevis débridement or release within 2 years were identified using similar methods. A multivariate binomial logistic regression analysis was used to evaluate patient-related risk factors for revision surgery. In addition, the number of preoperative injections (1, 2, or ≥3) in the ipsilateral elbow was identified and included in the regression analysis. Adjusted odds ratios (OR) and 95% confidence intervals were calculated for each risk factor. Of 3863 patients who underwent operative treatment of lateral epicondylitis, 58 (1.5%) required ipsilateral revision surgery. Risk factors for revision surgery included age lateral epicondylitis in the studied population is low (1.5%). Risk factors for revision surgery include younger age, male gender, morbid obesity, tobacco use, and inflammatory arthritis. The most significant risk factor for revision surgery is having ≥3 ipsilateral preoperative injections. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  20. Immersed single-drop microextraction interfaced with sequential injection analysis for determination of Cr(VI) in natural waters by electrothermal-atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Pena, Francisco; Lavilla, Isela [Departamento de Quimica Analitica y Alimentaria, Area de Quimica Analitica, Facultad de Quimica, Universidad de Vigo, Campus As Lagoas-Marcosende, s/n, 36310 Vigo (Spain); Bendicho, Carlos [Departamento de Quimica Analitica y Alimentaria, Area de Quimica Analitica, Facultad de Quimica, Universidad de Vigo, Campus As Lagoas-Marcosende, s/n, 36310 Vigo (Spain)], E-mail: bendicho@uvigo.es

    2008-04-15

    Single-drop microextraction (SDME) and sequential injection analysis have been hyphenated for ultratrace metal determination by Electrothermal-Atomic Absorption Spectrometry (ETAAS). The novel method was targeted on extraction of the Cr(VI)-APDC chelate and encompasses the potential of SDME as a miniaturized and virtually solvent-free preconcentration technique, the ability of sequential injection analysis to handle samples and the versatility of furnace autosamplers for introducing microliter samples in ETAAS. The variables influencing the microextraction of Cr(VI) onto an organic solvent drop, i.e., type of organic solvent, microextraction time, stirring rate of the sample solution, drop volume, immersion depth of the drop, salting-out effect, temperature of the sample, concentration of the complexing agent and pH of the sample solution were fully investigated. For a 5 and 20 min microextraction time, the preconcentration factors were 20 and 70, respectively. The detection limit was 0.02 {mu}g/L of Cr(VI) and the repeatability expressed as relative standard deviation was 7%. The SDME-SIA-ETAAS technique was validated against BCR CRM 544 (lyophilized solution) and applied to ultrasensitive determination of Cr(VI) in natural waters.

  1. Optimization of Injection Molding Parameters for HDPE/TiO₂ Nanocomposites Fabrication with Multiple Performance Characteristics Using the Taguchi Method and Grey Relational Analysis.

    Science.gov (United States)

    Pervez, Hifsa; Mozumder, Mohammad S; Mourad, Abdel-Hamid I

    2016-08-22

    The current study presents an investigation on the optimization of injection molding parameters of HDPE/TiO₂ nanocomposites using grey relational analysis with the Taguchi method. Four control factors, including filler concentration (i.e., TiO₂), barrel temperature, residence time and holding time, were chosen at three different levels of each. Mechanical properties, such as yield strength, Young's modulus and elongation, were selected as the performance targets. Nine experimental runs were carried out based on the Taguchi L₉ orthogonal array, and the data were processed according to the grey relational steps. The optimal process parameters were found based on the average responses of the grey relational grades, and the ideal operating conditions were found to be a filler concentration of 5 wt % TiO₂, a barrel temperature of 225 °C, a residence time of 30 min and a holding time of 20 s. Moreover, analysis of variance (ANOVA) has also been applied to identify the most significant factor, and the percentage of TiO₂ nanoparticles was found to have the most significant effect on the properties of the HDPE/TiO₂ nanocomposites fabricated through the injection molding process.

  2. Optimization of Injection Molding Parameters for HDPE/TiO2 Nanocomposites Fabrication with Multiple Performance Characteristics Using the Taguchi Method and Grey Relational Analysis

    Directory of Open Access Journals (Sweden)

    Hifsa Pervez

    2016-08-01

    Full Text Available The current study presents an investigation on the optimization of injection molding parameters of HDPE/TiO2 nanocomposites using grey relational analysis with the Taguchi method. Four control factors, including filler concentration (i.e., TiO2, barrel temperature, residence time and holding time, were chosen at three different levels of each. Mechanical properties, such as yield strength, Young’s modulus and elongation, were selected as the performance targets. Nine experimental runs were carried out based on the Taguchi L9 orthogonal array, and the data were processed according to the grey relational steps. The optimal process parameters were found based on the average responses of the grey relational grades, and the ideal operating conditions were found to be a filler concentration of 5 wt % TiO2, a barrel temperature of 225 °C, a residence time of 30 min and a holding time of 20 s. Moreover, analysis of variance (ANOVA has also been applied to identify the most significant factor, and the percentage of TiO2 nanoparticles was found to have the most significant effect on the properties of the HDPE/TiO2 nanocomposites fabricated through the injection molding process.

  3. Optimization of Injection Molding Parameters for HDPE/TiO2 Nanocomposites Fabrication with Multiple Performance Characteristics Using the Taguchi Method and Grey Relational Analysis

    Science.gov (United States)

    Pervez, Hifsa; Mozumder, Mohammad S.; Mourad, Abdel-Hamid I.

    2016-01-01

    The current study presents an investigation on the optimization of injection molding parameters of HDPE/TiO2 nanocomposites using grey relational analysis with the Taguchi method. Four control factors, including filler concentration (i.e., TiO2), barrel temperature, residence time and holding time, were chosen at three different levels of each. Mechanical properties, such as yield strength, Young’s modulus and elongation, were selected as the performance targets. Nine experimental runs were carried out based on the Taguchi L9 orthogonal array, and the data were processed according to the grey relational steps. The optimal process parameters were found based on the average responses of the grey relational grades, and the ideal operating conditions were found to be a filler concentration of 5 wt % TiO2, a barrel temperature of 225 °C, a residence time of 30 min and a holding time of 20 s. Moreover, analysis of variance (ANOVA) has also been applied to identify the most significant factor, and the percentage of TiO2 nanoparticles was found to have the most significant effect on the properties of the HDPE/TiO2 nanocomposites fabricated through the injection molding process. PMID:28773830

  4. Analysis the effect of advanced injection strategies on engine performance and pollutant emissions in a heavy duty DI-diesel engine by CFD modeling

    International Nuclear Information System (INIS)

    Mobasheri, Raouf; Peng, Zhijun; Mirsalim, Seyed Mostafa

    2012-01-01

    Highlights: ► Explore the effects of advanced multiple injection strategies in a DI-diesel engine. ► Achieving good agreement between the predicted results and experimental values. ► Analyzing three factors for optimization including pilot, main and post-injection. ► Injecting adequate fuel in each pulse accompanied with an appropriate EGR rate. ► Beneficial effects for significant soot reduction without a NOx penalty rate. - Abstract: An Advanced CFD simulation has been carried out in order to explore the combined effects of pilot-, post- and multiple-fuel injection strategies and EGR on engine performance and emission formation in a heavy duty DI-diesel engine. An improved version of the ECFM-3Z combustion model has been applied coupled with advanced models for NOx and soot formation. The model was validated with experimental data achieved from a Caterpillar 3401 DI diesel engine and good agreement between predicted and measured in-cylinder pressure, heat release rate, NOx and soot emissions was obtained. The optimizations were conducted separately for different split injection cases without pilot injection and then, for various multiple injection cases. Totally, three factors were considered for the injection optimization, which included EGR rate, the separation between main injection and post-injection and the amount of injected fuel in each pulse. For the multiple injection cases, two more factors (including double and triple injections during main injection) were also added. Results show that using pilot injection accompanied with an optimized main injection has a significant beneficial effect on combustion process so that it could form a separate 2nd stage of heat release which could reduce the maximum combustion temperature, which leads to the reduction of the NOx formation. In addition, it has found that injecting adequate fuel in post-injection at an appropriate EGR allows significant soot reduction without a NOx penalty rate.

  5. SQL Injection Defenses

    CERN Document Server

    Nystrom, Martin

    2007-01-01

    This Short Cut introduces you to how SQL injection vulnerabilities work, what makes applications vulnerable, and how to protect them. It helps you find your vulnerabilities with analysis and testing tools and describes simple approaches for fixing them in the most popular web-programming languages. This Short Cut also helps you protect your live applications by describing how to monitor for and block attacks before your data is stolen. Hacking is an increasingly criminal enterprise, and web applications are an attractive path to identity theft. If the applications you build, manage, or guar

  6. Characterization of organic and conventional sweet basil leaves using chromatographic and flow-injection mass spectrometric (FIMS) fingerprints combined with principal component analysis

    Science.gov (United States)

    Lu, Yingjian; Gao, Boyan; Chen, Pei; Charles, Denys; Yu, Liangli (Lucy)

    2014-01-01

    Sweet basil, Ocimum basilicum., is one of the most important and wildly used spices and has been shown to have antioxidant, antibacterial, and anti-diarrheal activities. In this study, high performance liquid chromatographic (HPLC) and flow-injection mass spectrometric (FIMS) fingerprinting techniques were used to differentiate organic and conventional sweet basil leaf samples. Principal component analysis (PCA) of the fingerprints indicated that both HPLC and FIMS fingerprints could effectively detect the chemical differences in the organic and conventional sweet basil leaf samples. This study suggested that the organic basil sample contained greater concentrations of almost all the major compounds than its conventional counterpart on a per same botanical weight basis. The FIMS method was able to rapidly differentiate the organic and conventional sweet basil leaf samples (1 min analysis time), whereas the HPLC fingerprints provided more information about the chemical composition of the basil samples with a longer analytical time. PMID:24518341

  7. Incorporation of flow injection analysis with dual-wavelength overlapping resonance Rayleigh scattering for rapid determination of malachite green and its metabolite in fish.

    Science.gov (United States)

    Zhu, Jinghui; Qin, Mingyou; Liu, Shaopu; Liu, Zhongfang; Yang, Jidong; Hu, Xiaoli

    2014-09-15

    A flow injection analysis (FIA) system combined with dual-wavelength overlapping resonance Rayleigh scattering (DWO-RRS) has been established and validated for rapid determination of malachite green (MG) and its metabolite in fish samples. Under experimental condition, MG would react with Erythrosin (Ery) to form ion-association complexes, resulting in the occurrence of two RRS peaks and a dramatic enhancement of RRS intensity. The maximum RRS peaks were located at 286 nm and 337 nm. It is noted that the increments of both of these two peaks were proportional to the concentration of MG. The detection limit of DWO-RRS was 1.5 ng/mL, which was comparable to several reported methods. Moreover, the results of real sample analysis exhibited an acceptable recovery between 97.5% and 103.6%, indicating that the method had good reproducibility. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Rapid and simultaneous determination of neptunium and plutonium isotopes in environmental samples by extraction chromatography using sequential injection analysis and ICP-MS

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2010-01-01

    plutonium and neptunium in three reference materials were in agreement with the recommended or literature values at the 0.05 significance level. The developed method is suitable for the analysis of up to 10 g of soil and 20 g of seaweed samples. The extraction chromatographic separation within the SI system......This paper reports an automated analytical method for rapid and simultaneous determination of plutonium isotopes (239Pu and 240Pu) and neptunium (237Np) in environmental samples. An extraction chromatographic column packed with TrisKem TEVA® resin was incorporated in a sequential injection (SI...... for a single sample takes less than 1.5 h. As compared to batchwise procedures, the developed method significantly improves the analysis efficiency, reduces the labor intensity and expedites the simultaneous determination of plutonium and neptunium as demanded in emergency actions....

  9. Nonsurgical Treatments of Patellar Tendinopathy: Multiple Injections of Platelet-Rich Plasma Are a Suitable Option: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Andriolo, Luca; Altamura, Sante Alessandro; Reale, Davide; Candrian, Christian; Zaffagnini, Stefano; Filardo, Giuseppe

    2018-03-01

    Patellar tendinopathy is a condition characterized by anterior knee activity-related pain. It has a high incidence among athletes engaged in jumping sports and may become a chronic condition. Nonoperative management is the first choice in these patients, and several nonsurgical treatment options have been proposed. Nonetheless, clear indications on the most effective approach to address patellar tendinopathy are still lacking. To analyze the evidence on nonoperative options to treat chronic patellar tendinopathy through a systematic review of the literature and to perform a meta-analysis to identify the most effective nonsurgical option. Systematic review and meta-analysis. The search was conducted with the PubMed and Cochrane databases on January 4, 2017. All clinical English-language reports of any level of evidence on nonsurgical treatment of patellar tendinopathy were included. The quality of each article was assessed by use of the Coleman score. A meta-analysis was performed on all articles reporting the Victorian Institute of Sport Assessment scale for patellar tendinopathy to evaluate the results of the most described treatments. A total of 70 studies involving 2530 patients were included in the qualitative data synthesis. The Coleman score showed an overall poor study quality. The most described treatment groups that could be included in the meta-analysis were reported in 22 studies on eccentric exercise, extracorporeal shockwave therapy (ESWT), and platelet-rich plasma (PRP). Single and multiple PRP injections were evaluated separately. Eccentric exercise therapies obtained the best results ( P patellar tendinopathy with important limitations in terms of study quality. The available evidence showed an overall positive outcome, but some differences have been highlighted. Eccentric exercises may seem the strategy of choice in the short-term, but multiple PRP injections may offer more satisfactory results at long-term follow-up and can be therefore considered

  10. An Analysis of Rheological Properties of Inconel 625 Superalloy Feedstocks Formulated with Backbone Binder Polypropylene System for Powder Injection Molding

    Directory of Open Access Journals (Sweden)

    Gökmen U.

    2017-12-01

    Full Text Available Binder formula is one of the most significant factors which has a considerable influence on powder injection molding (PIM processes. In the study, rheological behaviors and properties of different binder systems containing PIM feedstocks, Inconel 625 powder commonly used in space industry, were investigated. The feedstocks were prepared 59%-69% (volume powder loading ratios with three diversified binder systems by use of Polypropylene as backbone binder. The average particle size of the Inconel 625 powder used was 12.86 microns. Components used in the binder were mixed for 30 minutes as dry in three dimensional mixing to prepare binder systems. Rheological features of the feedstock were characterized by using a capillary rheometer. Viscosities of the feedstocks were calculated within the range of 37.996-1900 Pa.s based on the shear rate, shear stress, binder formula and temperature. “n” parameters for PIM feedstocks were determined to be less than 1. Influences of temperature on the viscosities of the feedstocks were also studied and “Ea” under various shear stresses were determined within the range of 24.41-70.89 kJ/mol.

  11. A Comparative Analysis of Taguchi Methodology and Shainin System DoE in the Optimization of Injection Molding Process Parameters

    Science.gov (United States)

    Khavekar, Rajendra; Vasudevan, Hari, Dr.; Modi, Bhavik

    2017-08-01

    Two well-known Design of Experiments (DoE) methodologies, such as Taguchi Methods (TM) and Shainin Systems (SS) are compared and analyzed in this study through their implementation in a plastic injection molding unit. Experiments were performed at a perfume bottle cap manufacturing company (made by acrylic material) using TM and SS to find out the root cause of defects and to optimize the process parameters for minimum rejection. Experiments obtained the rejection rate to be 8.57% from 40% (appx.) during trial runs, which is quiet low, representing successful implementation of these DoE methods. The comparison showed that both methodologies gave same set of variables as critical for defect reduction, but with change in their significance order. Also, Taguchi methods require more number of experiments and consume more time compared to the Shainin System. Shainin system is less complicated and is easy to implement, whereas Taguchi methods is statistically more reliable for optimization of process parameters. Finally, experimentations implied that DoE methods are strong and reliable in implementation, as organizations attempt to improve the quality through optimization.

  12. RELAP5/MOD3.3 Analysis of the Loss of External Power Event with Safety Injection Actuation

    Directory of Open Access Journals (Sweden)

    Andrej Prošek

    2018-01-01

    Full Text Available The code assessment typically comprises basic tests cases, separate effects test, and integral effects tests. On the other hand, the thermal hydraulic system codes like RELAP5/MOD3.3 are primarily intended for simulation of transients and accidents in light water reactors. The plant measured data come mostly from startup tests and operational events. Also, for operational events the measured plant data may not be sufficient to explain all details of the event. The purpose of this study was therefore besides code assessment to demonstrate that simulations can be very beneficial for deep understanding of the plant response and further corrective measures. The abnormal event with reactor trip and safety injection signal actuation was simulated with the latest RELAP5/MOD3.3 Patch 05 best-estimate thermal hydraulic computer code. The measured and simulated data agree well considering the major plant system responses and operator actions. This suggests that the RELAP5 code simulation is good representative of the plant response and can complement not available information from plant measured data. In such a way, an event can be better understood.

  13. An analysis of respondent driven sampling with Injection Drug Users (IDU) in Albania and the Russian Federation.

    Science.gov (United States)

    Stormer, Ame; Tun, Waimar; Guli, Lisa; Harxhi, Arjan; Bodanovskaia, Zinaida; Yakovleva, Anna; Rusakova, Maia; Levina, Olga; Bani, Roland; Rjepaj, Klodian; Bino, Silva

    2006-11-01

    Injection drug users in Tirana, Albania and St. Petersburg, Russia were recruited into a study assessing HIV-related behaviors and HIV serostatus using Respondent Driven Sampling (RDS), a peer-driven recruitment sampling strategy that results in a probability sample. (Salganik M, Heckathorn DD. Sampling and estimation in hidden populations using respondent-driven sampling. Sociol Method. 2004;34:193-239). This paper presents a comparison of RDS implementation, findings on network and recruitment characteristics, and lessons learned. Initiated with 13 to 15 seeds, approximately 200 IDUs were recruited within 8 weeks. Information resulting from RDS indicates that social network patterns from the two studies differ greatly. Female IDUs in Tirana had smaller network sizes than male IDUs, unlike in St. Petersburg where female IDUs had larger network sizes than male IDUs. Recruitment patterns in each country also differed by demographic categories. Recruitment analyses indicate that IDUs form socially distinct groups by sex in Tirana, whereas there was a greater degree of gender mixing patterns in St. Petersburg. RDS proved to be an effective means of surveying these hard-to-reach populations.

  14. Thermal hydraulic analysis of aggressive secondary cooldown in a small break loss of coolant accident with a total loss of high pressure safety injection

    International Nuclear Information System (INIS)

    Han, Seok Jung; Lim, Ho Gon; Yang, Joon Eon

    2003-01-01

    To support the development of a Probabilistic Safety Assessment (PSA) model usable in Riskinformed Applications (RIA) for Korea Standard Nuclear power Plants (KSNP), we have performed a thermal hydraulic analysis of Aggressive Secondary Cooldown (ASC) in a 2-inch Small Break Loss Of Coolant Accident (SBLOCA) with a total loss of High Pressure Safety Injection (HPSI). The present study focuses on the estimation of the success criteria of ASC, and the enhanced understanding of the detailed thermal hydraulic behavior and phenomena. The results have shown that the Reactor Coolant System (RCS) pressure can be reduced to the Low Pressure Safety Injection (LPSI) operation conditions without core damage. It was also shown that more relaxed success criteria compared to those in the previous PSA models of KSNP could be used in the new PSA model. However, it was found that the results could be affected by various parameters related with ASC operation, i.e., reference temperature for the calculation of the cooldown rate and its control method

  15. Issues in the economic evaluation of influenza vaccination by injection of healthy working adults in the US: a review and decision analysis of ten published studies.

    Science.gov (United States)

    Hogan, Thomas J

    2012-05-01

    The objective was to review recent economic evaluations of influenza vaccination by injection in the US, assess their evidence, and conclude on their collective findings. The literature was searched for economic evaluations of influenza vaccination injection in healthy working adults in the US published since 1995. Ten evaluations described in nine papers were identified. These were synopsized and their results evaluated, the basic structure of all evaluations was ascertained, and sensitivity of outcomes to changes in parameter values were explored using a decision model. Areas to improve economic evaluations were noted. Eight of nine evaluations with credible economic outcomes were favourable to vaccination, representing a statistically significant result compared with a proportion of 50% that would be expected if vaccination and no vaccination were economically equivalent. Evaluations shared a basic structure, but differed considerably with respect to cost components, assumptions, methods, and parameter estimates. Sensitivity analysis indicated that changes in parameter values within the feasible range, individually or simultaneously, could reverse economic outcomes. Given stated misgivings, the methods of estimating influenza reduction ascribed to vaccination must be researched to confirm that they produce accurate and reliable estimates. Research is also needed to improve estimates of the costs per case of influenza illness and the costs of vaccination. Based on their assumptions, the reviewed papers collectively appear to support the economic benefits of influenza vaccination of healthy adults. Yet the underlying assumptions, methods and parameter estimates themselves warrant further research to confirm they are accurate, reliable and appropriate to economic evaluation purposes.

  16. Use of microscopy techniques in failure analysis of the plastic injection molded parts to prevent the risks of serial defects in the assembly processes

    Directory of Open Access Journals (Sweden)

    Braga Ion Cristian

    2017-01-01

    Full Text Available Nowadays, the plastic injected molded parts are components used in the automobile for both exterior and interior. A mechatronic device uses those molded parts for actuating in order to reach some effect; therefore they should be durable and aesthetically satisfying the customer requirements. The aim of this paper is to present the use of microscopy techniques in failure analysis of plastic molded parts as part of a mechatronic device in order to prevent the risks of cracking occurred in the serial assembly production. Due to the constraints, the thin walls are used in some small plastic parts and they can be broken in the next assembly steps, but the detection of the defects is not facile. At the validation of the batch, the sampling parts are tested to simulate the breakage and the tear zone is investigated using microscopy techniques. The information is used as a feedback to adjust the injection parameters, reference samples being created by experiments to support the team to reduce the time for adjusting the parameters.

  17. Determination of boron in natural water and products derived from grape using an automated flow injection analysis system with piezoelectric detection

    International Nuclear Information System (INIS)

    Jesus, Dosil P. de; Saito, Renata M.; Lago, Claudimir L. do

    2004-01-01

    An automated flow injection analysis system with piezoelectric detection is proposed as a sensitive and selective method for boron. The detector is an electrode-separated piezoelectric quartz crystal coated with N-methyl-D-glucamine-modified poly(epichlorohydrin). The film ability to retain boron allows the adjustment of the linear dynamic range and the sensitivity by varying the injected sample volume. In the present work, the sample volumes were varied from 0.5 to 5.0 mL. Among several ionic species, germanate is the only one that can interfere in the method. Nevertheless, it can be eliminated by addition of sulfide to the sample. The method was successfully applied to the determination of boron concentration in samples of natural water (from 1.71 to 309 μL -1 ) and products derived from grape juice (from 2.06 to 6.21 mg L -1 ). A pretreatment with hydrogen peroxide in alkaline medium was required due to the great amount of sugars in the grape products (author)

  18. Simultaneous Determination of Iron, Copper and Cobalt in Food Samples by CCD-diode Array Detection-Flow Injection Analysis with Partial Least Squares Calibration Model

    International Nuclear Information System (INIS)

    Mi Jiaping; Li Yuanqian; Zhou Xiaoli; Zheng Bo; Zhou Ying

    2006-01-01

    A flow injection-CCD diode array detection spectrophotometry with partial least squares (PLS) program for simultaneous determination of iron, copper and cobalt in food samples has been established. The method was based on the chromogenic reaction of the three metal ions and 2- (5-Bromo-2-pyridylazo)-5-diethylaminophenol, 5-Br-PADAP in acetic acid - sodium acetate buffer solution (pH5) with Triton X-100 and ascorbic acid. The overlapped spectra of the colored complexes were collected by charge-coupled device (CCD) - diode array detector and the multi-wavelength absorbance data was processed using partial least squares (PLS) algorithm. Optimum reaction conditions and parameters of flow injection analysis were investigated. The samples of tea, sesame, laver, millet, cornmeal, mung bean and soybean powder were determined by the proposed method. The average recoveries of spiked samples were 91.80%∼100.9% for Iron, 92.50%∼108.0% for Copper, 93.00%∼110.5% for Cobalt, respectively with relative standard deviation (R.S.D) of 1.1%∼12.1%. The sampling rate is 45 samples h -1 . The determination results of the food samples were in good agreement between the proposed method and ICP-AES

  19. Simultaneous Determination of Iron, Copper and Cobalt in Food Samples by CCD-diode Array Detection-Flow Injection Analysis with Partial Least Squares Calibration Model

    Energy Technology Data Exchange (ETDEWEB)

    Mi Jiaping; Li Yuanqian; Zhou Xiaoli; Zheng Bo; Zhou Ying [West China School of Public Health, Sichuan University, Chengdu, 610041 (China)

    2006-01-01

    A flow injection-CCD diode array detection spectrophotometry with partial least squares (PLS) program for simultaneous determination of iron, copper and cobalt in food samples has been established. The method was based on the chromogenic reaction of the three metal ions and 2- (5-Bromo-2-pyridylazo)-5-diethylaminophenol, 5-Br-PADAP in acetic acid - sodium acetate buffer solution (pH5) with Triton X-100 and ascorbic acid. The overlapped spectra of the colored complexes were collected by charge-coupled device (CCD) - diode array detector and the multi-wavelength absorbance data was processed using partial least squares (PLS) algorithm. Optimum reaction conditions and parameters of flow injection analysis were investigated. The samples of tea, sesame, laver, millet, cornmeal, mung bean and soybean powder were determined by the proposed method. The average recoveries of spiked samples were 91.80%{approx}100.9% for Iron, 92.50%{approx}108.0% for Copper, 93.00%{approx}110.5% for Cobalt, respectively with relative standard deviation (R.S.D) of 1.1%{approx}12.1%. The sampling rate is 45 samples h{sup -1}. The determination results of the food samples were in good agreement between the proposed method and ICP-AES.

  20. Simultaneous Determination of Iron, Copper and Cobalt in Food Samples by CCD-diode Array Detection-Flow Injection Analysis with Partial Least Squares Calibration Model

    Science.gov (United States)

    Mi, Jiaping; Li, Yuanqian; Zhou, Xiaoli; Zheng, Bo; Zhou, Ying

    2006-01-01

    A flow injection-CCD diode array detection spectrophotometry with partial least squares (PLS) program for simultaneous determination of iron, copper and cobalt in food samples has been established. The method was based on the chromogenic reaction of the three metal ions and 2- (5-Bromo-2-pyridylazo)-5-diethylaminophenol, 5-Br-PADAP in acetic acid - sodium acetate buffer solution (pH5) with Triton X-100 and ascorbic acid. The overlapped spectra of the colored complexes were collected by charge-coupled device (CCD) - diode array detector and the multi-wavelength absorbance data was processed using partial least squares (PLS) algorithm. Optimum reaction conditions and parameters of flow injection analysis were investigated. The samples of tea, sesame, laver, millet, cornmeal, mung bean and soybean powder were determined by the proposed method. The average recoveries of spiked samples were 91.80%~100.9% for Iron, 92.50%~108.0% for Copper, 93.00%~110.5% for Cobalt, respectively with relative standard deviation (R.S.D) of 1.1%~12.1%. The sampling rate is 45 samples h-1. The determination results of the food samples were in good agreement between the proposed method and ICP-AES.

  1. Comparison of intracytoplasmic sperm injection with testicular spermatozoa success in infertile men with obstructive and non-obstructive azoospermia; a retrospective analysis.

    Science.gov (United States)

    Yalcin, Ibrahim; Berker, Bulent; Sukur, Yavuz Emre; Kahraman, Korhan; Ates, Can

    2017-09-01

    The aim of this study was to compare the outcome of intracytoplasmic sperm injection (ICSI) and embryo transfer between couples with infertility due to male non-obstructive azoospermia (NOA) and obstructive azoospermia (OA). A retrospective analysis of 234 couples with azoospermia who were treated by ICSI and embryo transfer between January 2007 and October 2010 was performed. There were 61 couples in NOA group and 173 couples in OA group. Fertilization rates, pregnancy and clinical pregnancy rates were the main outcome measures. The number of retrieved mature oocytes, injected oocytes, metaphase II (MII) oocytes, two distinct pronuclei oocytes, cleavage embryos and embryos transferred was not significantly different between the groups. The fertilization rate was significantly lower in NOA group when compared to OA group (56.2 vs. 66.7%, respectively; p = 0.013) and the pregnancy rate was significantly lower in NOA group than OA group (36.1 vs. 50.9%, respectively; p = 0.046). The clinical pregnancy rates were not statistically different between the patients with NOA and OA azoospermia groups (24.6 vs. 36.4%, respectively; p = 0.09). This study suggests that ICSI and embryo transfer together with testicular sperm extraction results in statistically significant lower fertilization and pregnancy rates in men with NOA when compared to men with OA.

  2. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... Background: Of the estimated 384,000 needle-stick injuries occurring in hospitals each year, 23% occur in surgical settings. This study was conducted to assess safe injection procedures, injection practices, and circumstances contributing to needlestick and sharps injures (NSSIs) in operating rooms.

  3. Quality Assessment of Kumu Injection, a Traditional Chinese Medicine Preparation, Using HPLC Combined with Chemometric Methods and Qualitative and Quantitative Analysis of Multiple Alkaloids by Single Marker.

    Science.gov (United States)

    Wang, Ning; Li, Zhi-Yong; Zheng, Xiao-Li; Li, Qiao; Yang, Xin; Xu, Hui

    2018-04-09

    Kumu injection (KMI) is a common-used traditional Chinese medicine (TCM) preparation made from Picrasma quassioides (D. Don) Benn. rich in alkaloids. An innovative technique for quality assessment of KMI was developed using high performance liquid chromatography (HPLC) combined with chemometric methods and qualitative and quantitative analysis of multi-components by single marker (QAMS). Nigakinone (PQ-6, 5-hydroxy-4-methoxycanthin-6-one), one of the most abundant alkaloids responsible for the major pharmacological activities of Kumu, was used as a reference substance. Six alkaloids in KMI were quantified, including 6-hydroxy- β -carboline-1-carboxylic acid (PQ-1), 4,5-dimethoxycanthin-6-one (PQ-2), β -carboline-1-carboxylic acid (PQ-3), β -carboline-1-propanoic acid (PQ-4), 3-methylcanthin-5,6-dione (PQ-5), and PQ-6. Based on the outcomes of twenty batches of KMI samples, the contents of six alkaloids were used for further chemometric analysis. By hierarchical cluster analysis (HCA), radar plots, and principal component analysis (PCA), all the KMI samples could be categorized into three groups, which were closely related to production date and indicated the crucial influence of herbal raw material on end products of KMI. QAMS combined with chemometric analysis could accurately measure and clearly distinguish the different quality samples of KMI. Hence, QAMS is a feasible and promising method for the quality control of KMI.

  4. Thermo-economic analysis of a solid oxide fuel cell and steam injected gas turbine plant integrated with woodchips gasification

    DEFF Research Database (Denmark)

    Mazzucco, Andrea; Rokni, Masoud

    2014-01-01

    cost on the generation cost is also presented. In order to discuss the investment cost, an economic analysis has been carried out and main parameters such as Net Present Value (NPV), internal rate of return (IRR) and Time of Return of Investment (TIR) are calculated and discussed.......% respectively which are significantly greater than conventional 10 MWe plants fed by biomass. Thermo-economic analysis provides an average cost of electricity for best performing layouts close to 6.4 and 9.4 c€/kWe which is competitive within the market. A sensitivity analysis of the influence of SOFC stack...

  5. The Use of Flow-Injection Analysis with Chemiluminescence Detection of Aqueous Ferrous Iron in Waters Containing High Concentrations of Organic Compounds

    Directory of Open Access Journals (Sweden)

    Carrick M. Eggleston

    2009-06-01

    Full Text Available An evaluation of flow-injection analysis with chemiluminescence detection (FIA-CL to quantify Fe2+(aq in freshwaters was performed. Iron-coordinating and/or iron-reducing compounds, dissolved organic matter (DOM, and samples from two natural water systems were used to amend standard solutions of Fe2+(aq. Slopes of the response curves from ferrous iron standards (1 – 100 nM were compared to the response curves of iron standards containing the amendments. Results suggest that FIA-CL is not suitable for systems containing ascorbate, hydroxylamine, cysteine or DOM. Little or no change in sensitivity occurred in solutions of oxalate and glycine or in natural waters with little organic matter.

  6. International patent applications for non-injectable naloxone for opioid overdose reversal: Exploratory search and retrieve analysis of the PatentScope database.

    Science.gov (United States)

    McDonald, Rebecca; Danielsson Glende, Øyvind; Dale, Ola; Strang, John

    2018-02-01

    Non-injectable naloxone formulations are being developed for opioid overdose reversal, but only limited data have been published in the peer-reviewed domain. Through examination of a hitherto-unsearched database, we expand public knowledge of non-injectable formulations, tracing their development and novelty, with the aim to describe and compare their pharmacokinetic properties. (i) The PatentScope database of the World Intellectual Property Organization was searched for relevant English-language patent applications; (ii) Pharmacokinetic data were extracted, collated and analysed; (iii) PubMed was searched using Boolean search query '(nasal OR intranasal OR nose OR buccal OR sublingual) AND naloxone AND pharmacokinetics'. Five hundred and twenty-two PatentScope and 56 PubMed records were identified: three published international patent applications and five peer-reviewed papers were eligible. Pharmacokinetic data were available for intranasal, sublingual, and reference routes. Highly concentrated formulations (10-40 mg mL -1 ) had been developed and tested. Sublingual bioavailability was very low (1%; relative to intravenous). Non-concentrated intranasal spray (1 mg mL -1 ; 1 mL per nostril) had low bioavailability (11%). Concentrated intranasal formulations (≥10 mg mL -1 ) had bioavailability of 21-42% (relative to intravenous) and 26-57% (relative to intramuscular), with peak concentrations (dose-adjusted C max  = 0.8-1.7 ng mL -1 ) reached in 19-30 min (t max ). Exploratory analysis identified intranasal bioavailability as associated positively with dose and negatively with volume. We find consistent direction of development of intranasal sprays to high-concentration, low-volume formulations with bioavailability in the 20-60% range. These have potential to deliver a therapeutic dose in 0.1 mL volume. [McDonald R, Danielsson Glende Ø, Dale O, Strang J. International patent applications for non-injectable naloxone for opioid overdose reversal

  7. From clinical evidence to everyday practice: implementing findings from a cost-effectiveness analysis for endoscopic injection therapy for upper-gastrointestinal bleeding.

    Science.gov (United States)

    Sitter, Helmut; Lorenz, Wilfried; Nicolay, Uwe; Krack, Walter; Hellenbrandt, Armin; Zielke, Andreas; Gajek, Hartwig; Ledertheil, Gertrud

    2003-03-01

    A previous upper-gastrointestinal bleeding trial showed that patients treated with repeated fibrin glue injection for upper-gastrointestinal bleeding have significantly less rebleeding than those treated with polidocanol. To analyse the cost and effectiveness of repeated fibrin glue injection and to investigate whether these results change physicians' attitudes. A retrospective random sample of five hospitals from the previous study, collection of cost identification, and follow-up data on 320 patients (155 in the polidocanol group, 165 in the fibrin glue group). An incremental cost-effectiveness analysis and comparison of outcomes was performed using chi-squared tests and Kaplan-Meier survival analysis. A survey was carried out using a questionnaire in the five hospitals on local guidelines for management of ulcer bleeding, and its results were analysed qualitatively. The measure of effectiveness is the number of prevented rebleedings. Further variables were length of hospital stay and length of intensive care unit (ICU) stay. The cost for the prevention of one additional rebleeding by repeated fibrin glue treatment amounts to 14,316 +/- 4981 euros (incremental cost-effectiveness ratio). There were no significant differences in length of stays in ICU or in hospital. The physicians did not change their management plans for patients with upper-gastrointestinal bleeding. In a survey, it was seen that other factors, such as local guidelines, attitudes towards new treatment options, and ease of handling of drugs, are more important than a result of a single study for a behavioural change of the doctors. The study was not designed prospectively to address a pharmacoeconomic question. As relevant variables (e.g. length of ICU stay) could not be reliably ascertained retrospectively, this may lead to biased estimates of the incremental cost-effectiveness ratio.

  8. Long-acting injectable paliperidone palmitate versus oral paliperidone extended release: a comparative analysis from two placebo-controlled relapse prevention studies.

    Science.gov (United States)

    Markowitz, Michael; Fu, Dong-Jing; Levitan, Bennett; Gopal, Srihari; Turkoz, Ibrahim; Alphs, Larry

    2013-07-11

    Increasing availability and use of long-acting injectable antipsychotics have generated a need to compare these formulations with their oral equivalents; however, a paucity of relevant data is available. This post hoc comparison of the long-term efficacy, safety and tolerability of maintenance treatment with paliperidone palmitate (PP) versus oral paliperidone extended release (ER) used data from two similarly designed, randomised, double-blind (DB), placebo-controlled schizophrenia relapse prevention trials. Assessments included measures of time to relapse, symptom changes/functioning and treatment-emergent adverse events (TEAEs). Time to relapse between treatment groups was evaluated using a Cox proportional hazards model. Between-group differences for continuous variables for change scores during the DB phase were assessed using analysis of co-variance models. Categorical variables were evaluated using Chi-square and Fisher's exact tests. No adjustment was made for multiplicity. Approximately 45% of enrolled subjects in both trials were stabilised and randomised to the DB relapse prevention phase. Risk of relapse was higher in subjects treated with paliperidone ER than in those treated with PP [paliperidone ER/PP hazard ratio (HR), 2.52; 95% confidence interval (CI), 1.46-4.35; p 70, both approximately 58.5%; p = 1.000] compared with a 10.9% decrease for paliperidone ER (58.5% vs 47.6%, respectively; p = 0.048). The least squares mean change for Positive and Negative Syndrome Scale (PANSS) total score at DB end point in these previously stabilised subjects was 3.5 points in favour of PP (6.0 vs 2.5; p = 0.025). The rates of TEAEs and AEs of interest appeared similar. This analysis supports maintenance of effect with the injectable compared with the oral formulation of paliperidone in patients with schizophrenia. The safety profile of PP was similar to that of paliperidone ER. Future studies are needed to confirm these findings.

  9. Sodium Ferric Gluconate Injection

    Science.gov (United States)

    Sodium ferric gluconate injection is used to treat iron-deficiency anemia (a lower than normal number of ... are also receiving the medication epoetin (Epogen, Procrit). Sodium ferric gluconate injection is in a class of ...

  10. Calcitonin Salmon Injection

    Science.gov (United States)

    Calcitonin salmon injection is used to treat osteoporosis in postmenopausal women. Osteoporosis is a disease that causes bones to weaken and break more easily. Calcitonin salmon injection is also used to treat Paget's disease ...

  11. Iron Dextran Injection

    Science.gov (United States)

    Iron dextran injection is used to treat iron-deficiency anemia (a lower than normal number of red blood cells ... treated with iron supplements taken by mouth. Iron dextran injection is in a class of medications called ...

  12. Aminocaproic Acid Injection

    Science.gov (United States)

    Aminocaproic acid injection is used to control bleeding that occurs when blood clots are broken down too quickly. This ... the baby is ready to be born). Aminocaproic acid injection is also used to control bleeding in ...

  13. Deoxycholic Acid Injection

    Science.gov (United States)

    Deoxycholic acid injection is used to improve the appearance and profile of moderate to severe submental fat ('double chin'; fatty tissue located under the chin). Deoxycholic acid injection is in a class of medications called ...

  14. Cluster beam injection

    International Nuclear Information System (INIS)

    Bottiglioni, F.; Coutant, J.; Fois, M.

    1978-01-01

    Areas of possible applications of cluster injection are discussed. The deposition inside the plasma of molecules, issued from the dissociation of the injected clusters, has been computed. Some empirical scaling laws for the penetration are given

  15. Antigen injection (image)

    Science.gov (United States)

    Leprosy is caused by the organism Mycobacterium leprae . The leprosy test involves injection of an antigen just under ... if your body has a current or recent leprosy infection. The injection site is labeled and examined ...

  16. US-Approved Intra-Articular Hyaluronic Acid Injections are Safe and Effective in Patients with Knee Osteoarthritis: Systematic Review and Meta-Analysis of Randomized, Saline-Controlled Trials

    Science.gov (United States)

    Miller, Larry E.; Block, Jon E.

    2013-01-01

    We conducted a systematic review and meta-analysis of randomized saline-controlled trials to determine the safety and efficacy of US-approved intra-articular hyaluronic acid (IAHA) injections for symptomatic knee osteoarthritis. A total of 29 studies representing 4,866 unique subjects (IAHA: 2,673, saline: 2,193) were included. IAHA injection resulted in very large treatment effects between 4 and 26 weeks for knee pain and function compared to pre-injection values, with standardized mean difference (SMD) values ranging from 1.07–1.37 (all P injection of US-approved HA products is safe and efficacious in patients with symptomatic knee osteoarthritis. PMID:24027421

  17. Prevalence of injections and knowledge of safe injections among rural residents in Central China.

    Science.gov (United States)

    Yan, Y W; Yan, J; Zhang, G P; Gao, Z L; Jian, H X

    2007-08-01

    Abuse of the injection services, namely unnecessary injections and unsafe injections, exists extensively in developing countries. Unsafe injection practices contribute to the transmission of blood-borne pathogens. The aims of this study were to survey the prevalence of injections and knowledge of injection safety among the rural residents in Jingzhou district, Hubei, China and to provide scientific data for developing a health educational programme. A retrospective cross-sectional study was conducted in 12 villages, which were selected from the Jingzhou district by the random sampling method. 50 rural residents were interviewed per village using a questionnaire. Among the 595 residents studied, 192 had received at least one injection in the past three months, with an injection prevalence of 32.3 percent and an average of 0.93 injections. 90.3 percent of the rural residents knew that unsafe injections could transmit the following blood-borne pathogens: human immunodeficiency virus (74.4 percent), hepatitis B virus (55.8 percent) and hepatitis C virus (22.9 percent). Logistic regression analysis showed that the residents' age, educational level and residential area were important factors in influencing their knowledge about injection safety. The results indicated that the injection prevalence was high among rural residents in the study area, and their knowledge regarding injection safety should be further improved.

  18. Water pollution screening by large-volume injection of aqueous samples and application to GC/MS analysis of a river Elbe sample

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, S.; Efer, J.; Engewald, W. [Leipzig Univ. (Germany). Inst. fuer Analytische Chemie

    1997-03-01

    The large-volume sampling of aqueous samples in a programmed temperature vaporizer (PTV) injector was used successfully for the target and non-target analysis of real samples. In this still rarely applied method, e.g., 1 mL of the water sample to be analyzed is slowly injected direct into the PTV. The vaporized water is eliminated through the split vent. The analytes are concentrated onto an adsorbent inside the insert and subsequently thermally desorbed. The capability of the method is demonstrated using a sample from the river Elbe. By means of coupling this method with a mass selective detector in SIM mode (target analysis) the method allows the determination of pollutants in the concentration range up to 0.01 {mu}g/L. Furthermore, PTV enrichment is an effective and time-saving method for non-target analysis in SCAN mode. In a sample from the river Elbe over 20 compounds were identified. (orig.) With 3 figs., 2 tabs.

  19. Effects of sample injection amount and time-of-flight mass spectrometric detection dynamic range on metabolome analysis by high-performance chemical isotope labeling LC-MS.

    Science.gov (United States)

    Zhou, Ruokun; Li, Liang

    2015-04-06

    The effect of sample injection amount on metabolome analysis in a chemical isotope labeling (CIL) liquid chromatography-mass spectrometry (LC-MS) platform was investigated. The performance of time-of-flight (TOF) mass spectrometers with and without a high-dynamic-range (HD) detection system was compared in the analysis of (12)C2/(13)C2-dansyl labeled human urine samples. An average of 1635 ± 21 (n = 3) peak pairs or putative metabolites was detected using the HD-TOF-MS, compared to 1429 ± 37 peak pairs from a conventional or non-HD TOF-MS. In both instruments, signal saturation was observed. However, in the HD-TOF-MS, signal saturation was mainly caused by the ionization process, while in the non-HD TOF-MS, it was caused by the detection process. To extend the MS detection range in the non-HD TOF-MS, an automated switching from using (12)C to (13)C-natural abundance peaks for peak ratio calculation when the (12)C peaks are saturated has been implemented in IsoMS, a software tool for processing CIL LC-MS data. This work illustrates that injecting an optimal sample amount is important to maximize the metabolome coverage while avoiding the sample carryover problem often associated with over-injection. A TOF mass spectrometer with an enhanced detection dynamic range can also significantly increase the number of peak pairs detected. In chemical isotope labeling (CIL) LC-MS, relative metabolite quantification is done by measuring the peak ratio of a (13)C2-/(12)C2-labeled peak pair for a given metabolite present in two comparative samples. The dynamic range of peak ratio measurement does not need to be very large, as only subtle changes of metabolite concentrations are encountered in most metabolomic studies where relative metabolome quantification of different groups of samples is performed. However, the absolute concentrations of different metabolites can be very different, requiring a technique to provide a wide detection dynamic range to allow the detection of as

  20. A Cost Analysis of Hospitalizations for Infections Related to Injection Drug Use at a County Safety-Net Hospital in Miami, Florida

    OpenAIRE

    Tookes, Hansel; Diaz, Chanelle; Li, Hua; Khalid, Rafi; Doblecki-Lewis, Susanne

    2015-01-01

    Background Infections related to injection drug use are common. Harm reduction strategies such as syringe exchange programs and skin care clinics aim to prevent these infections in injection drug users (IDUs). Syringe exchange programs are currently prohibited by law in Florida. The goal of this study was to estimate the mortality and cost of injection drug use-related bacterial infections over a 12-month period to the county safety-net hospital in Miami, Florida. Additionally, the prevalence...