WorldWideScience

Sample records for injection equipment missed

  1. Tertiary recovery and tritide injection equipment

    International Nuclear Information System (INIS)

    Li Lin

    1989-01-01

    The exploitation of an oil field is a continously developing process, undergoing seveal stages, such as the low production, the high production, the stable production and the decline. The tertiary recovery is an important means of the enhanced oil recovery. Since the object of the tertiary recovery is to treat the oil in micropores which is difficult to be produced, it is more necessary to know further the reservoir. Tritide can be used as a tracer and is an ideal marker of knowing the reservoir and the state of the fluid movement. The paper presents the tritide injection equipment

  2. Medical equipment in government health facilities: Missed opportunities

    OpenAIRE

    Pardeshi Geeta

    2005-01-01

    BACKGROUND: The availability and optimal utilization of medical equipment is important for improving the quality of health services. Significant investments are made for the purchase, maintenance and repair of medical equipment. Inadequate management of these equipment will result in financial losses and deprive the public of the intended benefits. This analysis is based on the conceptual framework drawn from the WHO recommended- lifecycle of medical equipment. AIMS: (1) To identify the probl...

  3. Medical equipment in government health facilities: missed opportunities.

    Science.gov (United States)

    Pardeshi, Geeta S

    2005-01-01

    The availability and optimal utilization of medical equipment is important for improving the quality of health services. Significant investments are made for the purchase, maintenance and repair of medical equipment. Inadequate management of these equipment will result in financial losses and deprive the public of the intended benefits. This analysis is based on the conceptual framework drawn from the WHO recommended- lifecycle of medical equipment. (1) To identify the problems in different stages of the life cycle. (2) To assess its financial implications and effect on service delivery. Analysis of secondary data from the latest Comptroller and Auditor General (CAG) Reports for the states in India. The study variables were category of equipment, financial implications and problems in the stages of life cycle. Calculation of proportions. A total of forty instances mentioning problems in the first phase of the life cycle of medical equipment were noted in 12 state reports. The equipment from the radiology department (15), equipment in the wards (5), laboratory (3) and operation theatres (4) were the ones most frequently implicated. In a majority of cases the financial implications amounted to twenty-five lakhs. The financial implications were in the form of extra expenditure, unfruitful expenditure or locking of funds. In 25 cases the equipment could not be put to use because of non-availability of trained staff and inadequate infrastructural support. Careful procurement, incoming inspection, successful installation and synchronization of qualified trained staff and infrastructural support will ensure timely onset of use of the equipment.

  4. Injection of tennis elbow: Hit and miss? A cadaveric study of injection accuracy

    NARCIS (Netherlands)

    Keijsers, Renee; van den Bekerom, Michel P. J.; Koenraadt, Koen L. M.; Bleys, Ronald L. A. W.; van Dijk, C. Niek; Eygendaal, Denise; van Riet, Roger; Middernacht, Bart; Defoort, Saartje; Wagener, Marc; Harake, Ramzi; Ciornohac, Jean-Florin; Montarnal, Robert; van Benthem, Yasmin; Cattaneo, Stefano; Faber, Dirk; Galatz, Leesa; Birkisson, Illugi; van der Hoeven, Henk; Witjes, Suzanne; Heeren, M.; Ahmed, El-Gammal; Husif, N. N.; Beumer, Annechien; The, Bertram

    2017-01-01

    Different injection therapies are used in the treatment of lateral epicondylitis (LE). Usually, the extensor carpi radialis brevis (ECRB) tendon is affected. Therefore, an injection should be aimed at the origin of this tendon. This study demonstrates the accuracy of manual injections in the

  5. Predictors of sharing injection equipment by HIV-seropositive injection drug users.

    Science.gov (United States)

    Latkin, Carl A; Buchanan, Amy S; Metsch, Lisa R; Knight, Kelly; Latka, Mary H; Mizuno, Yuko; Knowlton, Amy R

    2008-12-01

    Among HIV-positive injection drug users (IDUs), we examined baseline predictors of lending needles and syringes and sharing cookers, cotton, and rinse water in the prior 3 months at follow-up. Participants were enrolled in Intervention for Seropositive Injectors-Research and Evaluation, a secondary prevention intervention for sexually active HIV-positive IDUs in 4 US cities during 2001-2005. The analyses involved 357 participants who reported injecting drugs in the prior 6 months at either the 6- or 12-month follow-up visit. About half (49%) reported at least 1 sharing episode. In adjusted analyses, peer norms supporting safer injection practices and having primary HIV medical care visits in the prior 6 months were associated with reporting no sharing of injection equipment. Higher levels of psychological distress were associated with a greater likelihood of reporting drug paraphernalia sharing. These findings suggest that intervention approaches for reducing HIV-seropositive IDUs' transmission of blood-borne infections should include peer-focused interventions to alter norms of drug paraphernalia sharing and promoting primary HIV care and mental health services.

  6. A framework of induced hyperspace dynamical systems equipped with the hit-or-miss topology

    International Nuclear Information System (INIS)

    Wang Yangeng; Wei Guo; Campbell, William H.; Bourquin, Steven

    2009-01-01

    For any dynamical system (E,d,f), where E is Hausdorff locally compact second countable (HLCSC), let F (resp., 2 E ) denote the space of all closed subsets (resp., non-empty closed subsets) of E equipped with the hit-or-miss topology τ f . Both F and 2 E are again HLCSC (F actually compact), thus metrizable. Let ρ be such a metric (three metrics available). The main purpose is to determine the conditions on f that ensure the continuity of the induced hyperspace maps 2 f :F→F and 2 f :2 E →2 E defined by 2 f (F)=f(F). With this setting, the induced hyperspace systems (F,ρ,2 f ) and (2 E ,ρ,2 f ) are compact and locally compact dynamical systems, respectively. Consequently, dynamical properties, particularly metric related dynamical properties, of the given system (E,d,f) can be explored through these hyperspace systems. In contrast, when the Vietoris topology τ v is equipped on 2 E , the space of the induced hyperspace topological dynamical system (2 E ,τ v ,2 f ) is not metrizable if E is not compact metrizable, e.g., E=R n , implying that metric related dynamical concepts cannot be defined for (2 E ,τ v ,2 f ). Moreover, two examples are provided to illustrate the advantages of the hit-or-miss topology as compared to the Vietoris topology.

  7. Alternative water injection device to reactor equipment facility

    International Nuclear Information System (INIS)

    Yamashita, Masahiro.

    1995-01-01

    The device of the present invention injects water to the reactor and the reactor container continuously for a long period of time for preventing occurrence of a severe accident in a BWR type reactor and maintaining the integrity of the reactor container even if the accident should occur. Namely, diesel-driven pumps disposed near heat exchangers of a reactor after-heat removing system (RHR) are operated before the reactor is damaged by the after heat to cause reactor melting. A sucking valve disposed to a pump sucking pipeline connecting a secondary pipeline of the RHR heat exchanger and the diesel driving pump is opened. A discharge valve disposed to a pump discharge pipeline connecting a primary pipeline of the RHR heat exchanger and the diesel driving pump is opened. With such procedures, sea water is introduced from a sea water taking port through the top end of the secondary pipeline of the RHR heat exchanger and water is injected into the inside of the pressure vessel or the reactor container by way of the primary pipeline of the RHR heat exchanger. As a result, the reactor core is prevented from melting even upon occurrence of a severe accident. (I.S.)

  8. AN EXPERIMENTAL NOX REDUCTION POTENTIAL INVESTIGATION OF THE PARTIAL HCCI APPLICATION, ON A HIGH PRESSURE FUEL INJECTION EQUIPPED DIESEL ENGINE BY IMPLEMENTING FUMIGATION OF GASOLINE PORT INJECTION

    OpenAIRE

    ERGENÇ, Alp Tekin; YÜKSEK, Levent; ÖZENER, Orkun; IŞIN, Övün

    2016-01-01

    This work investigates the effects of partial HCCI (Homogeneous charge compression ignition) application on today's modern diesel engine tail pipe NOx emissions. Gasoline fumigation is supplied via a port fuel injection system located in the intake port of DI(Direct injection) diesel engine to maintain partial HCCI conditions and also diesel fuel injected directly into the combustion chamber before TDC(Top dead center). A single cylinder direct injection diesel research engine equipped w...

  9. The Use of Particulate Injection Moulding for Fabrication of Sports and Leisure Equipment from Titanium Metals

    Directory of Open Access Journals (Sweden)

    Paul D. Ewart

    2018-02-01

    Full Text Available Advanced materials such as metal alloys, carbon fibre composites and engineered polymers have improved athlete performances in all sporting applications. Advances in manufacturing has enabled increases in design complexity and the ability to rapidly prototype bespoke products using additive manufacturing also known as 3D printing. Another recent fabrication method widely used by medical, electronics and armaments manufacturers is particulate injection moulding. This process uses exact quantities of the required material, in powder form, minimising resource and energy requirements in comparison to conventional manufacturing techniques. The process utilises injection moulding techniques and tooling methods developed and used in the plastics industry. It can produce highly complex component geometries with excellent repeatability and reduced cost where volume manufacturing is required. This is especially important when considering materials such as titanium that are not only expensive in comparison to other metals but are difficult to process by regular machining and fabrication methods. This work presents a review of titanium use in the sporting sector with a focus on sporting devices and equipment. It also proposes that the sports engineering sector could increase performance and enable improvements in safety by switching to design methods appropriate to processing via the particulate injection moulding route.

  10. Lubrication and wear in diesel engine injection equipment fuelled by dimethyl ether (DME)

    DEFF Research Database (Denmark)

    Sivebæk, Ion Marius

    2003-01-01

    Dimethyl ether (DME) has been recognised as an excellent fuel for diesel engines for over one decade now. DME fueled engines emit virtually no particulate matter even at low NOx levels. DME has thereby the potential of reducing the diesel engine emissions without filters or other devices...... that jeopardise the high efficiency of the engine and increase the manufacturing costs. DME has a low toxicity and can be made from anything containing carbon including biomass. If DME is produced from cheap natural gas from remote locations, the price of this new fuel could even become lower than that of diesel...... oil. Fueling diesel engines with DME presents two significant problems: The injection equipment can break down due to extensive wear and DME attacks nearly all known elastomers. The latter problem renders dynamic sealing diƣult whereas the first one involves the poor lubrication qualities of DME which...

  11. Corrosion Study of the Injection Equipments in Water in Al-Ahdeb Wells ‐Iraq

    Directory of Open Access Journals (Sweden)

    Hassan Abdulkadhim Alwan Alsaadi

    2015-01-01

    Full Text Available Water injection equipments such as pipelines, which are used in the second recovery of oil in the Al-Ahdeb wells, suffer from the corrosion in water during maintaining vacuum deoxygenated tower that used to decrease concentration of the dissolved oxygen gas in the water from 6.2-9.1 ppm to o.5 ppm. This study involved calculation the corrosion rates of the internal surfaces of the pipelines either during operation of the vacuum unit or when the tower out of operation. Finally, find the solution by one of the following suggestions. In the first suggestion removal of the dissolved O2 from water is achieved by increasing the dosage of the oxygen scavenger (sodium sulphite. The second suggestion involves removing the dissolved O2 from water by bubbling the oxygenated water with nitrogen gas. The study showed that the corrosion rates of various inside diameter pipelines are between 0.13 mm/yr and 1.5 mm/yr during operation of the vacuum tower and between 3.2 mm/yr and 18.5 mm/yr when the tower out of the operation. While the results showed that the corrosion rate of the pipelines when the tower out of operation reached to the acceptable value of 0.1 mm/y when the dissolved oxygen in the injected water removed by increasing the dosage of the sodium sulphite (Na2SO3 to 48-72 ppm. The results also explained that corrosion rates of the pipelines reached to 0.5 mm/y when the dissolved oxygen removed by bubbling the water with nitrogen gas.

  12. A randomized intervention trial to reduce the lending of used injection equipment among injection drug users infected with hepatitis C.

    Science.gov (United States)

    Latka, Mary H; Hagan, Holly; Kapadia, Farzana; Golub, Elizabeth T; Bonner, Sebastian; Campbell, Jennifer V; Coady, Micaela H; Garfein, Richard S; Pu, Minya; Thomas, Dave L; Thiel, Thelma K; Strathdee, Steffanie A

    2008-05-01

    We evaluated the efficacy of a peer-mentoring behavioral intervention designed to reduce risky distributive injection practices (e.g., syringe lending, unsafe drug preparation) among injection drug users with hepatitis C virus (HCV) infection. A randomized trial with a time-equivalent attention-control group was conducted among 418 HCV-positive injection drug users aged 18 to 35 years in 3 US cities. Participants reported their injection-related behaviors at baseline and at 3- and 6-month follow-ups. Compared with the control group, intervention-group participants were less likely to report distributive risk behaviors at 3 months (odds ratio [OR]=0.46; 95% confidence interval [CI]=0.27, 0.79) and 6 months (OR=0.51; 95% CI=0.31, 0.83), a 26% relative risk reduction, but were no more likely to cite their HCV-positive status as a reason for refraining from syringe lending. Effects were strongest among intervention-group participants who had known their HCV-positive status for at least 6 months. Peer mentoring and self-efficacy were significantly increased among intervention-group participants, and intervention effects were mediated through improved self-efficacy. This behavioral intervention reduced unsafe injection practices that may propagate HCV among injection drug users.

  13. The importance of social networks in their association to drug equipment sharing among injection drug users: a review.

    Science.gov (United States)

    De, Prithwish; Cox, Joseph; Boivin, Jean-François; Platt, Robert W; Jolly, Ann M

    2007-11-01

    To examine the scientific evidence regarding the association between characteristics of social networks of injection drug users (IDUs) and the sharing of drug injection equipment. A search was performed on MEDLINE, EMBASE, BIOSIS, Current Contents, PsycINFO databases and other sources to identify published studies on social networks of IDUs. Papers were selected based on their examination of social network factors in relation to the sharing of syringes and drug preparation equipment (e.g. containers, filters, water). Additional relevant papers were found from the reference list of identified articles. Network correlates of drug equipment sharing are multi-factorial and include structural factors (network size, density, position, turnover), compositional factors (network member characteristics, role and quality of relationships with members) and behavioural factors (injecting norms, patterns of drug use, severity of drug addiction). Factors appear to be related differentially to equipment sharing. Social network characteristics are associated with drug injection risk behaviours and should be considered alongside personal risk behaviours in prevention programmes. Recommendations for future research into the social networks of IDUs are proposed.

  14. Draught requirement of trailing foot and shallow injection equipment for applying slurry to grassland

    NARCIS (Netherlands)

    Huijsmans, J.F.M.; Hendriks, J.L.G.; Vermeulen, G.D.

    1998-01-01

    Surface spreading of slurry leads to the inevitable emission of ammonia into the environment. Injection of slurry on grassland reduces these emissions. However, injection of slurry by deep working injector tines with goose foot chisels (wings) requires high draught forces. This type of injection has

  15. Reductions in HIV/STI Incidence and Sharing of Injection Equipment among Female Sex Workers Who Inject Drugs: Results from a Randomized Controlled Trial

    Science.gov (United States)

    Strathdee, Steffanie A.; Abramovitz, Daniela; Lozada, Remedios; Martinez, Gustavo; Rangel, Maria Gudelia; Vera, Alicia; Staines, Hugo; Magis-Rodriguez, Carlos; Patterson, Thomas L.

    2013-01-01

    Background We evaluated brief combination interventions to simultaneously reduce sexual and injection risks among female sex workers who inject drugs (FSW-IDUs) in Tijuana and Ciudad Juarez, Mexico during 2008–2010, when harm reduction coverage was expanding rapidly in Tijuana, but less so in Juarez. Methods FSW-IDUs ≥18 years reporting sharing injection equipment and unprotected sex with clients within the last month participated in a randomized factorial trial comparing four brief, single-session conditions combining either an interactive or didactic version of a sexual risk intervention to promote safer sex in the context of drug use, and an injection risk intervention to reduce sharing of needles/injection paraphernalia. Women underwent quarterly interviews and testing for HIV, syphilis, gonorrhea, Chlamydia and Trichomonas, blinding interviewers and assessors to assignment. Poisson regression with robust variance estimation and repeated measures ordinal logistic regression examined effects on combined HIV/STI incidence and receptive needle sharing frequency. Findings Of 584 initially HIV-negative FSW-IDUs, retention was ≥90%. After 12 months, HIV/STI incidence decreased >50% in the interactive vs. didactic sex intervention (Tijuana:AdjRR:0.38,95% CI:0.16–0.89; Juarez: AdjRR:0.44,95% CI:0.19–0.99). In Juarez, women receiving interactive vs. didactic injection risk interventions decreased receptive needle-sharing by 85% vs. 71%, respectively (p = 0.04); in Tijuana, receptive needle sharing declined by 95%, but was similar in active versus didactic groups. Tijuana women reported significant increases in access to syringes and condoms, but Juarez women did not. Interpretation After 12 months in both cities, the interactive sexual risk intervention significantly reduced HIV/STI incidence. Expanding free access to sterile syringes coupled with brief, didactic education on safer injection was necessary and sufficient for achieving robust, sustained

  16. Uncovering high rates of unsafe injection equipment reuse in rural Cameroon: validation of a survey instrument that probes for specific misconceptions

    Directory of Open Access Journals (Sweden)

    Reid Savanna R

    2011-02-01

    Full Text Available Abstract Background Unsafe reuse of injection equipment in hospitals is an on-going threat to patient safety in many parts of Africa. The extent of this problem is difficult to measure. Standard WHO injection safety assessment protocols used in the 2003 national injection safety assessment in Cameroon are problematic because health workers often behave differently under the observation of visitors. The main objective of this study is to assess the extent of unsafe injection equipment reuse and potential for blood-borne virus transmission in Cameroon. This can be done by probing for misconceptions about injection safety that explain reuse without sterilization. These misconceptions concern useless precautions against cross-contamination, i.e. "indirect reuse" of injection equipment. To investigate whether a shortage of supply explains unsafe reuse, we compared our survey data against records of purchases. Methods All health workers at public hospitals in two health districts in the Northwest Province of Cameroon were interviewed about their own injection practices. Injection equipment supply purchase records documented for January to December 2009 were compared with self-reported rates of syringe reuse. The number of HIV, HBV and HCV infections that result from unsafe medical injections in these health districts is estimated from the frequency of unsafe reuse, the number of injections performed, the probability that reused injection equipment had just been used on an infected patient, the size of the susceptible population, and the transmission efficiency of each virus in an injection. Results Injection equipment reuse occurs commonly in the Northwest Province of Cameroon, practiced by 44% of health workers at public hospitals. Self-reported rates of syringe reuse only partly explained by records on injection equipment supplied to these hospitals, showing a shortage of syringes where syringes are reused. Injection safety interventions could

  17. The injection equipment of future high-speed DI diesel engines with respect to power and pollution requirements

    Energy Technology Data Exchange (ETDEWEB)

    Dolenc, A. (Monobloc Dieselmotoren GmbH, Vienna (AT))

    1990-01-01

    The development of high specific output DI diesel engines started at the low-speed end some 50 years ago primarily for marine and traction applications. Movement towards the high-speed end has been slow but steady with the majority of truck engines being very conservatively rated. There has been recent major effort on the automotive car and light commercial vehicle diesel application leading to lightweight DI diesel engines with an engine speed of 4000-5000 r/min and a rated power of 50 kW/litre displacement. These are expected to be on the market in a short period of time. The key point of this development has been the injection equipment including combustion control. In this area the use of modulated injection has the possibility of solving power and pollution requirements. (author).

  18. Air injection evaluation in open steam discharge pipes based on ejector equipment theory

    International Nuclear Information System (INIS)

    Bigu, M.; Nita, I.; Tenescu, M.

    2005-01-01

    The paper starts from the finding that the calculation method proposed by ANSI B31.1 for open steam discharge pipes (normative 'ANSI/ASMF B31.1-1980 appendix II Non-Mandatory rules for the design of safety valve installation') shows an air injection in steam system without making a quantitative evaluation of this process of air injection in the exhaust steam. For this it is proposed an assimilation of process with an ejection process in which either steam or air is the ejected fluid. The reason of using opened exhaust systems instead of closed exhaust systems is the fact that expansions and especially shock load from discharge valves and especially in exhaust elbow, are not conducted over the pipe system (ventilation tube). In order to estimate the quantity of air flow which enters through the ejection effect the present paper makes use of gas-gas ejectors. The interest for optimal operating of the system is that the air mixture have a value low in comparison with steam flow (i.e. 2-3% or upmost 5-7%). These percents of mixture lead to properly choosing of the ratio of the two pipe diameters (ventilation tube D/ exhaust elbow d). The results show that optimum ratio is between D/d = 1.10 to 1.15 and in extreme cases 1.20. A lower value of ratio is not acceptable because the pipes come in direct contact when expansion and/or hydraulic hammer occur and stresses from exhaust elbow of safety valve are propagated towards ventilation tube. A higher value of the ratio D/d leads to great air injection in ventilation tube and so to an unjustified large diameter of ventilation tube. It must be mention that the optimal ratio is obtained at sub critical flow of ejected air with Mach number lower then unity, at a static pressure between 0.6 to 1.0 bar in mixture zone of the two fluids. (authors)

  19. Air injection evaluation in open steam discharge pipes based on ejector equipment theory

    International Nuclear Information System (INIS)

    Bigu, M.; Nita, I.; Tenescu, M.

    2005-01-01

    Full text: The paper starts from the finding that the calculation method proposed by ANSI B31.1 for open steam discharge pipes (normative 'ANSI/ASMF B31.1-1980 appendix II Non-Mandatory rules for the design of safety valve installation') shows an air injection in steam system without making a quantitative evaluation of this process of air injection in the exhaust steam. For this it is proposed an assimilation of process with an ejection process in which either steam or air is the ejected fluid. The reason of using opened exhaust systems instead of closed exhaust systems is the fact that expansions and especially shock load from discharge valves and especially in exhaust elbow, are not conducted over the pipe system (ventilation tube). In order to estimate the quantity of air flow which enters through the ejection effect the present paper makes use of gas-gas ejectors. The interest for optimal operating of the system is that the air mixture have a value low in comparison with steam flow (i.e. 2-3% or upmost 5-7%). These percents of mixture lead to properly choosing of the ratio of the two pipe diameters (ventilation tube D/ exhaust elbow d). The results show that optimum ratio is between D/d = 1.10 to 1.15 and in extreme cases 1.20. A lower value of ratio is not acceptable because the pipes come in direct contact when expansion and/or hydraulic hammer occur and stresses from exhaust elbow of safety valve are propagated towards ventilation tube. A higher value of the ratio D/d leads to great air injection in ventilation tube and so to an unjustified large diameter of ventilation tube. It must be mention that the optimal ratio is obtained at sub critical flow of ejected air with Mach number lower then unity, at a static pressure between 0.6 to 1.0 bar in mixture zone of the two fluids

  20. Effects of pilot injection parameters on low temperature combustion diesel engines equipped with solenoid injectors featuring conventional and rate-shaped main injection

    International Nuclear Information System (INIS)

    D’Ambrosio, S.; Ferrari, A.

    2016-01-01

    Highlights: • The influence of the principal pilot injection parameters is discussed for low-temperature combustion systems. • Swirl-sweep and dwell-time sweep results are combined to analyze soot emissions. • The pilot injection effects are investigated in injection profiles featuring rate-shaped main injections. - Abstract: The potential of pilot injection has been assessed on a low-temperature combustion diesel engine for automotive applications, which was characterized by a reduced compression-ratio, high EGR rates and postponed main injection timings. Dwell time sweeps have been carried out for pilot injections with distinct energizing times under different representative steady-state working conditions of the medium load and speed area of the New European Driving Cycle. The results of in-cylinder analyses of the pressure, heat-release rate, temperature and emissions are presented. Combustion noise has been shown to decrease significantly when the pilot injected mass increases, while it is scarcely affected by the dwell time between the pilot and main injections. The HC, CO and fuel consumption trends, with respect to both the pilot injection dwell time and mass, are in line with those of conventional combustion systems, and in particular decreasing trends occur as the pilot injection energizing time is increased. Furthermore, a reduced sensitivity of NO_x emissions to both dwell time and pilot injected mass has been found, compared to conventional combustion systems. Finally, it has been observed that soot emissions diminish as the energizing time is shortened, and their dependence on dwell time is influenced to a great extent by the presence of local zones with reduced air-to-fuel ratios within the cylinder. A combined analysis of the results of swirl sweeps and dwell time sweeps is here proposed as a methodology for the detection of any possible interference between pilot combustion burned gases and the main injected fuel. The effect of pilot

  1. Safety evaluation report on Westinghouse Electric Company ECCS evaluation model for plants equipped with upper head injection

    International Nuclear Information System (INIS)

    Lauben, G.N.; Wagner, N.H.; Israel, S.L.; McPherson, G.D.; Hodges, M.W.

    1978-04-01

    For plants which include an ice condenser containment concept, Westinghouse has planned an additional safety system known as the upper head injection (UHI) system to augment the emergency core cooling system. This system is comprised of additional accumulator tanks and piping arranged to supply cooling water to the top of the core during the blowdown period following a postulated large-break loss-of-coolant accident (LOCA). The objective of UHI is to add to the core cooling provided by the conventional emergency core cooling system (ECCS) and so permit operation at linear heat rates comparable to those permitted in plants utilizing the dry containment concept. In this way, plants which include the UHI system would have greater operating flexibility while still meeting the acceptance criteria as defined in paragraph 50.46 of 10 CFR Part 50. This review is concerned with those changes to the Westinghouse ECCS evaluation model that have been proposed for the UHI-LOCA model

  2. Determination of Anthracycline Drug Residual in Cleaning Validation Swabs of Stainless-Steel Equipment after Production of Cytostatic Injections Using HPLC Analytical Method

    Directory of Open Access Journals (Sweden)

    Zuzana Slivová

    2015-01-01

    Full Text Available Standard cleaning procedures of production line equipment were verified after manufacture of cytostatic injections containing Anthracycline derivate substance. Residual content of Anthracycline drug substance on stainless-steel equipment surface was determined using swab sampling with a specific HPLC-DAD analysis. The acceptance limit was decided as 200.0 μg/100 cm2. Recovery from the stainless-steel surface was 90.1%. Linearity of the method was observed in the concentration range of 0.155–194 μg/mL when estimated using Zorbax TMS (5 μm, 0.25 m × 4.6 mm ID column at 1.3 mL/min flow rate and 254 nm (DAD 190–600 nm. The mobile phase consisted of lauryl hydrogen sulphate solution (3.7 g/L : methanol : acetonitrile (54 : 16 : 30, v/v/v with pH adjusted to 2.5 using phosphoric acid (85%. The LOD and LOQ for Anthracycline derivate were found to be 0.047 and 0.155 μg/mL, respectively. The method validation confirmed the method provides acceptable degree of selectivity, linearity, accuracy, and precision for the intended purposes.

  3. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... sures regarding disposable injection equipment, waste containers, hand hygiene ... injection practices lead to high prevalence of NSSIs in operating rooms. .... guidelines, the availability of training courses to HCWs, and provi-.

  4. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Results: Safe injection procedures regarding final waste disposal were sufficiently adopted, while measures regarding disposable injection equipment, waste containers, hand hygiene, as well as injection practices were inadequately carried out. Lack of job aid posters that promote safe injection and safe disposal of ...

  5. Miss Lora juveelikauplus = Miss Lora jewellery store

    Index Scriptorium Estoniae

    2009-01-01

    Narvas Fama kaubanduskeskuses (Tallinna mnt. 19c) asuva juveelikaupluse Miss Lora sisekujundusest. Sisearhitektid Annes Arro ja Hanna Karits. Poe sisu - vitriinkapid, vaip, valgustid - on valmistatud eritellimusel. Sisearhitektide tähtsamate tööde loetelu

  6. Principled Missing Data Treatments.

    Science.gov (United States)

    Lang, Kyle M; Little, Todd D

    2018-04-01

    We review a number of issues regarding missing data treatments for intervention and prevention researchers. Many of the common missing data practices in prevention research are still, unfortunately, ill-advised (e.g., use of listwise and pairwise deletion, insufficient use of auxiliary variables). Our goal is to promote better practice in the handling of missing data. We review the current state of missing data methodology and recent missing data reporting in prevention research. We describe antiquated, ad hoc missing data treatments and discuss their limitations. We discuss two modern, principled missing data treatments: multiple imputation and full information maximum likelihood, and we offer practical tips on how to best employ these methods in prevention research. The principled missing data treatments that we discuss are couched in terms of how they improve causal and statistical inference in the prevention sciences. Our recommendations are firmly grounded in missing data theory and well-validated statistical principles for handling the missing data issues that are ubiquitous in biosocial and prevention research. We augment our broad survey of missing data analysis with references to more exhaustive resources.

  7. Equipment considerations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Trace or ultratrace analyses require that the HPLC equipment used, including the detector, be optimal for such determinations. HPLC detectors are discussed at length in Chapter 4; discussion here is limited to the rest of the equipment. In general, commercial equipment is adequate for trace analysis; however, as the authors approach ultratrace analysis, it becomes very important to examine the equipment thoroughly and optimize it, where possible. For this reason they will review the equipment commonly used in HPLC and discuss the optimization steps. Detectability in HPLC is influenced by two factors (1): (a) baseline noise or other interferences that lead to errors in assigning the baseline absorbance; (b) peak width. 87 refs

  8. Mining face equipment

    Energy Technology Data Exchange (ETDEWEB)

    G, Litvinskiy G; Babyuk, G V; Yakovenko, V A

    1981-01-07

    Mining face equipment includes drilling advance wells, drilling using explosives on the contour bore holes, loading and transporting the crushed mass, drilling reinforcement shafts, injecting reinforcement compounds and moving the timber. Camouflet explosives are used to form relaxed rock stress beyond the mining area to decrease costs of reinforcing the mining area by using nonstressed rock in the advance well as support. The strengthening solution is injected through advanced cementing wells before drilling the contour bores as well as through radial cementing wells beyond the timbers following loading and transport of the mining debris. The advance well is 50-80 m.

  9. Injection and Dump Systems

    CERN Document Server

    Bracco, C; Barnes, M J; Carlier, E; Drosdal, L N; Goddard, B; Kain, V; Meddahi, M; Mertens, V; Uythoven, J

    2012-01-01

    Performance and failures of the LHC injection and ex- traction systems are presented. In particular, a comparison with the 2010 run, lessons learnt during operation with high intensity beams and foreseen upgrades are described. UFOs, vacuum and impedance problems related to the injection and extraction equipment are analysed together with possible improvements and solutions. New implemented features, diagnostics, critical issues of XPOC and IQC applications are addressed.

  10. Advancing research in regeneration and repair of the motor circuitry: non-human primate models and imaging scales as the missing links for successfully translating injectable therapeutics to the clinic.

    Science.gov (United States)

    Tsintou, Magdalini; Dalamagkas, Kyriakos; Makris, Nikos

    2016-01-01

    Regeneration and repair is the ultimate goal of therapeutics in trauma of the central nervous system (CNS). Stroke and spinal cord injury (SCI) are two highly prevalent CNS disorders that remain incurable, despite numerous research studies and the clinical need for effective treatments. Neural engineering is a diverse biomedical field, that addresses these diseases using new approaches. Research in the field involves principally rodent models and biologically active, biodegradable hydrogels. Promising results have been reported in preclinical studies of CNS repair, demonstrating the great potential for the development of new treatments for the brain, spinal cord and peripheral nerve injury. Several obstacles stand in the way of clinical translation of neuroregeneration research. There seems to be a key gap in the translation of research from rodent models to human applications, namely non-human primate models, which constitute a critical bridging step. Applying injectable therapeutics and multimodal neuroimaging in stroke lesions using experimental rhesus monkey models is an avenue that a few research groups have begun to embark on. Understanding and assessing the changes that the injured brain or spinal cord undergoes after an intervention with biodegradable hydrogels in non-human primates seem to represent critical preclinical research steps. Existing innovative models in non-human primates allow us to evaluate the potential of neural engineering and injectable hydrogels. The results of these preliminary studies will pave the way for translating this research into much needed clinical therapeutic approaches. Cutting edge imaging technology using Connectome scanners represents a tremendous advancement, enabling the in vivo, detailed, high-resolution evaluation of these therapeutic interventions in experimental animals. Most importantly, they also allow quantifiable and clinically meaningful correlations with humans, increasing the translatability of these

  11. Netbooks The Missing Manual

    CERN Document Server

    Biersdorfer, J

    2009-01-01

    Netbooks are the hot new thing in PCs -- small, inexpensive laptops designed for web browsing, email, and working with web-based programs. But chances are you don't know how to choose a netbook, let alone use one. Not to worry: with this Missing Manual, you'll learn which netbook is right for you and how to set it up and use it for everything from spreadsheets for work to hobbies like gaming and photo sharing. Netbooks: The Missing Manual provides easy-to-follow instructions and lots of advice to help you: Learn the basics for using a Windows- or Linux-based netbookConnect speakers, printe

  12. PCs The Missing Manual

    CERN Document Server

    Karp, David

    2005-01-01

    Your vacuum comes with one. Even your blender comes with one. But your PC--something that costs a whole lot more and is likely to be used daily and for tasks of far greater importance and complexity--doesn't come with a printed manual. Thankfully, that's not a problem any longer: PCs: The Missing Manual explains everything you need to know about PCs, both inside and out, and how to keep them running smoothly and working the way you want them to work. A complete PC manual for both beginners and power users, PCs: The Missing Manual has something for everyone. PC novices will appreciate the una

  13. Testosterone Injection

    Science.gov (United States)

    ... typical male characteristics. Testosterone injection works by supplying synthetic testosterone to replace the testosterone that is normally ... as a pellet to be injected under the skin.Testosterone injection may control your symptoms but will ...

  14. Mani, Miss Anna Modayil

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 1960 Section: Earth & Planetary Sciences. Mani, Miss Anna Modayil A.I.I.Sc., FNA 1971-79; Secretary 1977-79. Date of birth: 23 August 1918. Date of death: 16 August 2001. Specialization: Atmospheric Physics and Instrumentation Last known address: c/o Mr K.T. Chandy, 14, ...

  15. Some 'Near Miss ' Experiences

    African Journals Online (AJOL)

    perienced health Workers, especially at lower level units, poor referral ... in the wards or operating theatre, and inability to access the busy health .... clinics, costs incurred and by who, who decided on hospitalisation, who .... pected pregnancy as I had missed my period the previous month. .... the patient received attention.

  16. The Missing Entrepreneurs 2014

    DEFF Research Database (Denmark)

    Halabisky, David; Potter, Jonathan; Thompson, Stuart

    OECD's LEED Programme and the European Commission's DG on Employment, Social Affairs and Inclusion recently published the second book as part of their programme of work on inclusive entrepreneurship. The Missing Entrepreneurs 2014 examines how public policies at national and local levels can...

  17. Missing School Matters

    Science.gov (United States)

    Balfanz, Robert

    2016-01-01

    Results of a survey conducted by the Office for Civil Rights show that 6 million public school students (13%) are not attending school regularly. Chronic absenteeism--defined as missing more than 10% of school for any reason--has been negatively linked to many key academic outcomes. Evidence shows that students who exit chronic absentee status can…

  18. Topology-Based Estimation of Missing Smart Meter Readings

    Directory of Open Access Journals (Sweden)

    Daisuke Kodaira

    2018-01-01

    Full Text Available Smart meters often fail to measure or transmit the data they record when measuring energy consumption, known as meter readings, owing to faulty measuring equipment or unreliable communication modules. Existing studies do not address successive and non-periodical missing meter readings. This paper proposes a method whereby missing readings observed at a node are estimated by using circuit theory principles that leverage the voltage and current data from adjacent nodes. A case study is used to demonstrate the ability of the proposed method to successfully estimate the missing readings over an entire day during which outages and unpredictable perturbations occurred.

  19. Injection safety practices in a main referral hospital in northeastern ...

    African Journals Online (AJOL)

    2013-03-25

    Mar 25, 2013 ... containers specific for non-sharps infectious waste and 17 (77.3%) of the observed therapeutic injections ..... injection safety, a high percentage was not complying .... the availability of loose disposable injection equipment.

  20. Respondent-driven sampling and the recruitment of people with small injecting networks.

    Science.gov (United States)

    Paquette, Dana; Bryant, Joanne; de Wit, John

    2012-05-01

    Respondent-driven sampling (RDS) is a form of chain-referral sampling, similar to snowball sampling, which was developed to reach hidden populations such as people who inject drugs (PWID). RDS is said to reach members of a hidden population that may not be accessible through other sampling methods. However, less attention has been paid as to whether there are segments of the population that are more likely to be missed by RDS. This study examined the ability of RDS to capture people with small injecting networks. A study of PWID, using RDS, was conducted in 2009 in Sydney, Australia. The size of participants' injecting networks was examined by recruitment chain and wave. Participants' injecting network characteristics were compared to those of participants from a separate pharmacy-based study. A logistic regression analysis was conducted to examine the characteristics independently associated with having small injecting networks, using the combined RDS and pharmacy-based samples. In comparison with the pharmacy-recruited participants, RDS participants were almost 80% less likely to have small injecting networks, after adjusting for other variables. RDS participants were also more likely to have their injecting networks form a larger proportion of those in their social networks, and to have acquaintances as part of their injecting networks. Compared to those with larger injecting networks, individuals with small injecting networks were equally likely to engage in receptive sharing of injecting equipment, but less likely to have had contact with prevention services. These findings suggest that those with small injecting networks are an important group to recruit, and that RDS is less likely to capture these individuals.

  1. Missed opportunities in crystallography.

    Science.gov (United States)

    Dauter, Zbigniew; Jaskolski, Mariusz

    2014-09-01

    Scrutinized from the perspective of time, the giants in the history of crystallography more than once missed a nearly obvious chance to make another great discovery, or went in the wrong direction. This review analyzes such missed opportunities focusing on macromolecular crystallographers (using Perutz, Pauling, Franklin as examples), although cases of particular historical (Kepler), methodological (Laue, Patterson) or structural (Pauling, Ramachandran) relevance are also described. Linus Pauling, in particular, is presented several times in different circumstances, as a man of vision, oversight, or even blindness. His example underscores the simple truth that also in science incessant creativity is inevitably connected with some probability of fault. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  2. Miss World going deshi

    DEFF Research Database (Denmark)

    Wildermuth, Norbert

      In November 1996 the South Indian metropolis Bangalore hosted the annual Miss World show. The live event and its televisualisation became a prominent symbol for the India's economic liberalisation and for the immanent globalizing dimensions of this development. As such, the highly prestigious......, the pageant's contestation, which gave rise to a series of vehement protests and a broad public debate about the country's cultural alienation, marked a crucial point in time and trend towards the (re)localisation of the Indian television landscape. In consequence, the 1996 Miss World show and its...... their vision and politics of gender, nation and modernity on the larger Indian public, over the last two decades. Engaging the Indian population increasingly by way of the new electronic, c&s distributed media, competing discourses of gender and sexuality were projected, basically as a necessary, effective...

  3. The missed diagnosis

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    One of the questions that haunts the radiologist as he shuffles through piles of films is ''What am I missing?'' This same question takes on even more meaning when the radiologist is pressed for time, when he reluctantly checks the night work of the resident, when the patient left before more or better films could be obtained; or when the radiologist is involved in a subspecialty in which he is not properly trained. According to Dr. Berlin's survey, the missed diagnosis category accounted for the largest number of radiology malpractice cases. We all know that many diagnoses are more easily made using the ''retrospectoscope.'' But is the plaintiff attorney also adept at using this instrument? Just how knowledgeable must the radiologist be in the use of the ''prospectoscope''? A familiarity with cases that have already been tried should at least alert radiologists to the chances of their own involvement in litigation. While the missed diagnosis is by no means peculiar to the radiologist, it is one of the principal reasons that he may find himself in court

  4. Semiparametric Theory and Missing Data

    CERN Document Server

    Tsiatis, Anastasios A

    2006-01-01

    Missing data arise in almost all scientific disciplines. In many cases, missing data in an analysis is treated in a casual and ad-hoc manner, leading to invalid inferences and erroneous conclusions. This book summarizes knowledge regarding the theory of estimation for semiparametric models with missing data.

  5. Granisetron Injection

    Science.gov (United States)

    Granisetron immediate-release injection is used to prevent nausea and vomiting caused by cancer chemotherapy and to ... nausea and vomiting that may occur after surgery. Granisetron extended-release (long-acting) injection is used with ...

  6. Edaravone Injection

    Science.gov (United States)

    Edaravone injection is used to treat amyotrophic lateral sclerosis (ALS, Lou Gehrig's disease; a condition in which ... die, causing the muscles to shrink and weaken). Edaravone injection is in a class of medications called ...

  7. Meropenem Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria that cause infection.Antibiotics such as meropenem injection will not work for colds, flu, or other viral infections. Taking ...

  8. Chloramphenicol Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by stopping the growth of bacteria..Antibiotics such as chloramphenicol injection will not work for colds, flu, or other viral infections. Taking ...

  9. Colistimethate Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria.Antibiotics such as colistimethate injection will not work for colds, flu, or other viral infections. Using ...

  10. Defibrotide Injection

    Science.gov (United States)

    Defibrotide injection is used to treat adults and children with hepatic veno-occlusive disease (VOD; blocked blood ... the body and then returned to the body). Defibrotide injection is in a class of medications called ...

  11. Nalbuphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using nalbuphine injection, you may experience withdrawal symptoms including restlessness; teary eyes; runny nose; yawning; ...

  12. Facebook The Missing Manual

    CERN Document Server

    Veer, E

    2011-01-01

    Facebook's spreading about as far and fast as the Web itself: 500 million members and counting. But there's a world of fun packed into the site that most folks miss. With this bestselling guide, learn how to unlock Facebook's talents as personal website creator, souped-up address book, and bustling community forum. It's an eye-opening, timesaving tour, guaranteed to help you get the most out of your Facebook experience. Coverage includes: Get started, get connected. Signing up is easy, but the real payoff comes when you tap into networks of coworkers, classmates, and friends. Pick and choose

  13. Usuários de drogas injetáveis e terapia anti-retroviral: percepções das equipes de farmácia Injecting drug users and antiretroviral therapy: perceptions of pharmacy teams

    Directory of Open Access Journals (Sweden)

    Chizuru Minami Yokaichiya

    2007-12-01

    Full Text Available OBJETIVO: Compreender as percepções das equipes de farmácia sobre seu papel nos desafios assistenciais e adesão aos anti-retrovirais de usuários de drogas injetáveis vivendo com HIV/Aids. MÉTODOS: Estudo qualitativo por grupos focais e análise temática das falas produzidas com farmacêuticos, técnicos e auxiliares com experiência superior a seis meses na dispensação de medicamentos, de 15 unidades assistenciais de DST/Aids do município de São Paulo, em 2002. RESULTADOS: Formaram-se três grupos, totalizando 29 participantes, provenientes de 12 dos 15 serviços existentes, com 12 universitários e 17 profissionais de nível médio. Os grupos concluíram que a farmácia tem importante papel na dispensação de anti-retrovirais, o que se reflete na adesão ao tratamento, pois por meio de seus procedimentos podem ser construídas relações de confiança. Avaliam, porém, que tal construção não ocorra pela excessiva burocratização de suas atividades. Isso repercute negativamente para todos os pacientes, em especial sobre usuários de drogas injetáveis, concebidos como "pessoas difíceis". Tal concepção essencializa seus comportamentos: seriam confusos, com limites de compreensão e sem possibilidades de adesão ao tratamento. Os profissionais, porém, afirmam que tratam esses pacientes tal como os demais, igualando-os. Não percebem neste proceder, uma invisibilização das necessidades específicas dos usuários de drogas injetáveis no serviço, bem como a possibilidade de gerarem estereótipos estigmatizantes com barreira adicional ao trabalho da adesão. CONCLUSÕES: Embora a farmácia seja indicada como espaço potencialmente favorável para escuta e construção de vínculos com os usuários, os resultados mostram obstáculos objetivos e subjetivos para torná-la propícia para trabalhar a adesão.OBJECTIVE: To understand the perceptions of pharmacy teams about their role in the healthcare assistance challenges and

  14. Predictors of Missed Research Appointments in a Randomized Placebo-Controlled Trial

    Directory of Open Access Journals (Sweden)

    Stéphanie J.E. Becker

    2014-09-01

     Younger patients with no college education, who believe their health can be controlled, are more likely to miss a research appointment when enrolled in a randomized placebo injection-controlled trial. 

  15. Damage limits of accelerator equipment

    CERN Document Server

    Rosell, Gemma

    2014-01-01

    Beam losses occur in particle accelerators for various reasons. The effect of lost particles on accelerator equipment becomes more severe with the increasing energies and intensities. The present study is focused on the damage potential of the proton beam as a function of particle energy and beam size. Injection and extraction energies of different accelerators at CERN were considered.

  16. Missed opportunities for HPV immunization among young adult women

    Science.gov (United States)

    Oliveira, Carlos R.; Rock, Robert M.; Shapiro, Eugene D.; Xu, Xiao; Lundsberg, Lisbet; Zhang, Liye B.; Gariepy, Aileen; Illuzzi, Jessica L.; Sheth, Sangini S.

    2018-01-01

    BACKGROUND Despite the availability of a safe and efficacious vaccine against human papillomavirus, uptake of the vaccine in the United States is low. Missed clinical opportunities to recommend and to administer human papillomavirus vaccine are considered one of the most important reasons for its low uptake in adolescents; however, little is known about the frequency or characteristics of missed opportunities in the young adult (18–26 years of age) population. OBJECTIVE The objective of the study was to assess both the rates of and the factors associated with missed opportunities for human papillomavirus immunization among young adult women who attended an urban obstetrics and gynecology clinic. STUDY DESIGN In this cross-sectional study, medical records were reviewed for all women 18–26 years of age who were underimmunized (<3 doses) and who sought care from Feb. 1, 2013, to January 31, 2014, at an urban, hospital-based obstetrics and gynecology clinic. A missed opportunity for human papillomavirus immunization was defined as a clinic visit at which the patient was eligible to receive the vaccine and a dose was due but not administered. Multivariable logistic regression was used to test associations between sociodemographic variables and missed opportunities. RESULTS There were 1670 vaccine-eligible visits by 1241 underimmunized women, with a mean of 1.3 missed opportunities/person. During the study period, 833 of the vaccine eligible women (67.1%) had at least 1 missed opportunity. Overall, the most common types of visits during which a missed opportunity occurred were postpartum visits (17%) or visits for either sexually transmitted disease screening (21%) or contraception (33%). Of the patients with a missed opportunity, 26.5% had a visit at which an injectable medication or a different vaccine was administered. Women who identified their race as black had higher adjusted odds of having a missed opportunity compared with white women (adjusted odds ratio, 1

  17. New or ν missing energy

    DEFF Research Database (Denmark)

    Franzosi, Diogo Buarque; Frandsen, Mads T.; Shoemaker, Ian M.

    2016-01-01

    flavor structures. Monojet data alone can be used to infer the mass of the "missing particle" from the shape of the missing energy distribution. In particular, 13 TeV LHC data will have sensitivity to DM masses greater than $\\sim$ 1 TeV. In addition to the monojet channel, NSI can be probed in multi......Missing energy signals such as monojets are a possible signature of Dark Matter (DM) at colliders. However, neutrino interactions beyond the Standard Model may also produce missing energy signals. In order to conclude that new "missing particles" are observed the hypothesis of BSM neutrino......-lepton searches which we find to yield stronger limits at heavy mediator masses. The sensitivity offered by these multi-lepton channels provide a method to reject or confirm the DM hypothesis in missing energy searches....

  18. Wikipedia the missing manual

    CERN Document Server

    Broughton, John

    2008-01-01

    Want to be part of the largest group-writing project in human history? Learn how to contribute to Wikipedia, the user-generated online reference for the 21st century. Considered more popular than eBay, Microsoft.com, and Amazon.com, Wikipedia servers respond to approximately 30,000 requests per second, or about 2.5 billion per day. It's become the first point of reference for people the world over who need a fact fast.If you want to jump on board and add to the content, Wikipedia: The Missing Manual is your first-class ticket. Wikipedia has more than 9 million entries in 250 languages, over 2

  19. Flexible Imputation of Missing Data

    CERN Document Server

    van Buuren, Stef

    2012-01-01

    Missing data form a problem in every scientific discipline, yet the techniques required to handle them are complicated and often lacking. One of the great ideas in statistical science--multiple imputation--fills gaps in the data with plausible values, the uncertainty of which is coded in the data itself. It also solves other problems, many of which are missing data problems in disguise. Flexible Imputation of Missing Data is supported by many examples using real data taken from the author's vast experience of collaborative research, and presents a practical guide for handling missing data unde

  20. [Hydrotherapy equipment].

    Science.gov (United States)

    Tsibikov, V B; Ragozin, S I; Mikheeva, L V

    1985-01-01

    A flow-chart is developed demonstrating the relation between medical and prophylactic institutions within the organizational structure of the rehabilitation system and main types of rehabilitation procedures. In order to ascertain the priority in equipping rehabilitation services with adequate hardware the special priority criterion is introduced. The highest priority is assigned to balneotherapeutic and fangotherapeutic services. Based on the operation-by-operation analysis of clinical processes related to service and performance of balneologic procedures the preliminary set of clinical devices designed for baths, basins and showers in hospitals and rehabilitation departments is defined in a generalized form.

  1. Cryogenic equipment

    International Nuclear Information System (INIS)

    Leger, L.; Javellaud, J.; Caro, C.; Gilguy, R.; Testard, O.

    1966-06-01

    The cryostats presented here were built from standard parts; this makes it possible to construct a great variety of apparatus at minimum cost. The liquid nitrogen and helium reservoirs were designed so as to reduce losses to a minimum, and so as to make the cryostats as autonomous as possible. The experimental enclosure which is generally placed in the lower part of the apparatus requires a separate study in every case. Furthermore, complete assemblies such as transfer rods, isolated traps and high vacuum valves, were designed with a similar regard for the economic aspects and for the need for standardization. This equipment thus satisfies a great variety of experimental needs; it is readily adaptable and the consumptions of helium and liquid nitrogen are very low. (authors) [fr

  2. Subcutaneous Injections

    DEFF Research Database (Denmark)

    Thomsen, Maria

    This thesis is about visualization and characterization of the tissue-device interaction during subcutaneous injection. The tissue pressure build-up during subcutaneous injections was measured in humans. The insulin pen FlexTouchr (Novo Nordisk A/S) was used for the measurements and the pressure ...

  3. Hydromorphone Injection

    Science.gov (United States)

    ... anyone else to use your medication. Store hydromorphone injection in a safe place so that no one else can use it accidentally or on purpose. Keep track of how much medication is left so ... with hydromorphone injection may increase the risk that you will develop ...

  4. Ketorolac Injection

    Science.gov (United States)

    ... an older adult, you should know that ketorolac injection is not as safe as other medications that can be used to treat your condition. Your doctor may choose to prescribe a different medication ... to ketorolac injection.Your doctor or pharmacist will give you the ...

  5. Paclitaxel Injection

    Science.gov (United States)

    (pak'' li tax' el)Paclitaxel injection must be given in a hospital or medical facility under the supervision of a doctor who is experienced in giving chemotherapy medications for cancer.Paclitaxel injection may cause a large decrease in the number of white blood cells (a type of blood cell ...

  6. Missing money and missing markets: Reliability, capacity auctions and interconnectors

    International Nuclear Information System (INIS)

    Newbery, David

    2016-01-01

    In the energy trilemma of reliability, sustainability and affordability, politicians treat reliability as over-riding. The EU assumes the energy-only Target Electricity Model will deliver reliability but the UK argues that a capacity remuneration mechanism is needed. This paper argues that capacity auctions tend to over-procure capacity, exacerbating the missing money problem they were designed to address. The bias is further exacerbated by failing to address some of the missing market problems also neglected in the debate. It examines the case for, criticisms of, and outcome of the first GB capacity auction and problems of trading between different capacity markets. - Highlights: •Energy-only markets can work if they avoid missing money and missing market problems. •Policy makers over-estimate the cost of so-called “loss of load events”. •Policy makers tend to over-procure capacity, exacerbating the missing money problem. •Rectifying missing market problems simplifies trade between different capacity markets. •Addressing missing market problems makes under-procurement cheaper than over-procurement.

  7. Conversations with Miss Jane

    Directory of Open Access Journals (Sweden)

    Geneviève Fabre

    2006-05-01

    Full Text Available Considering the wide range of conversations in the autobiography, this essay will attempt to appraise the importance of these verbal exchanges in relation to the overall narrative structure of the book and to the prevalent oral tradition in Louisiana culture, as both an individual and communal expression. The variety of circumstances, the setting and staging, the interlocutors , and the complex intersection of time and place, of stories and History, will be examined; in these conversations with Miss Jane many actors participate, from  the interviewer-narrator, to most characters; even the reader becomes involved.Speaking, hearing, listening, keeping silent is an elaborate ritual that performs many functions; besides conveying news or rumors, it imparts information on the times and on the life of a “representative” woman whose existence - spanning a whole century- is both singular and emblematic. Most importantly this essay will analyse the resonance of an eventful and often dramatic era on her sensibility and conversely show how her evolving sensibility informs that history and draws attention to aspects that might have passed unnoticed or be forever silenced. Jane’s desire for liberty and justice is often challenged as she faces the possibilities of life or death.Conversations build up a complex, often contradictory, but compelling portrait: torn between silence and vehemence, between memories and the urge to meet the future, Jane summons body and mind to find her way through the maze of a fast changing world; self-willed and obstinate she claims her right to speak, to express with wit and wisdom her firm belief in the word, in the ability to express deep seated convictions and faith and a whole array of feelings and emotions.

  8. INJECTING EQUPMENT SHARING AND PERCEPTION OF HIV AND HEPATITIS RISK AMONG INJECTING DRUG USERS IN BUDAPEST

    Science.gov (United States)

    Gyarmathy, V. Anna; Neaigus, Alan; Ujhelyi, Eszter

    2008-01-01

    In Central European states, rates of HIV among IDUs have been low although HCV infection is widespread. The goal of our study was to assess HIV infection, risk perceptions and injecting equipment sharing among injection drug users in Budapest, Hungary. Altogether 150 IDUs were interviewed (121 structured between 1999-2000 and 29 ethnographic between 2003-2004). The majority of them injected heroin (52% and 79%) and many injected amphetamines (51% and 35%). One person tested positive for HIV. Two thirds (68% of 121) shared injecting equipment (syringes, cookers and filters). Some participants said they shared syringes because they were not carrying them for fear of police harassment, and that they reused filters as a backup drug supply. In multivariate analysis, sharing of injecting equipment was associated with higher perceived susceptibility to HIV/AIDS, lower self-efficacy for sterile equipment use, higher motivation to comply with peer pressure to use dirty injecting equipment, and with having a criminal record. The high levels of injecting risk behaviors found in this study are a cause for serious concern. HIV prevention interventions need to address not only sharing syringes but also sharing and reusing other injecting equipment and drug filters. PMID:17129858

  9. Temozolomide Injection

    Science.gov (United States)

    ... balance or coordination fainting dizziness hair loss insomnia memory problems pain, itching, swelling, or redness in the place where the medication was injected changes in vision Some side effects can be serious. If you ...

  10. Buprenorphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opiate partial agonists. It works to prevent withdrawal symptoms ... help. If the victim has collapsed, had a seizure, has trouble breathing, or can't be awakened, ...

  11. Risperidone Injection

    Science.gov (United States)

    ... release (long-acting) injection is used to treat schizophrenia (a mental illness that causes disturbed or unusual ... may help control your symptoms but will not cure your condition. Continue to keep appointments to receive ...

  12. Haloperidol Injection

    Science.gov (United States)

    ... haloperidol extended-release injection are used to treat schizophrenia (a mental illness that causes disturbed or unusual ... may help control your symptoms but will not cure your condition. Continue to keep appointments to receive ...

  13. Omalizumab Injection

    Science.gov (United States)

    ... injection is used to decrease the number of asthma attacks (sudden episodes of wheezing, shortness of breath, and ... about how to treat symptoms of a sudden asthma attack. If your asthma symptoms get worse or if ...

  14. Injection Tests

    CERN Document Server

    Kain, V

    2009-01-01

    The success of the start-up of the LHC on 10th of September was in part due to the preparation without beam and injection tests in 2008. The injection tests allowed debugging and improvement in appropriate portions to allow safe, efficient and state-of-the-art commissioning later on. The usefulness of such an approach for a successful start-up becomes obvious when looking at the problems we encountered before and during the injection tests and could solve during this period. The outline of the preparation and highlights of the different injection tests will be presented and the excellent performance of many tools discussed. A list of shortcomings will follow, leading to some planning for the preparation of the run in 2009.

  15. Cefotaxime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefotaxime injection will not work for colds, flu, or other viral infections. Using ...

  16. Cefuroxime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefuroxime injection will not work for colds, flu, or other viral infections. Using ...

  17. Doripenem Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as doripenem injection will not work for colds, flu, or other viral infections. Taking ...

  18. Daptomycin Injection

    Science.gov (United States)

    ... in a class of medications called cyclic lipopeptide antibiotics. It works by killing bacteria.Antibiotics such as daptomycin injection will not work for treating colds, flu, or other viral infections. ...

  19. Ceftaroline Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftaroline injection will not work for colds, flu, or other viral infections. Using ...

  20. Aztreonam Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as aztreonam injection will not work for colds, flu, or other viral infections. Taking ...

  1. Cefazolin Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefazolin injection will not work for colds, flu, or other viral infections. Taking ...

  2. Ceftazidime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftazidime injection will not work for colds, flu, or other viral infections. Using ...

  3. Cefotetan Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefotetan injection will not work for colds, flu, or other viral infections. Using ...

  4. Cefoxitin Injection

    Science.gov (United States)

    ... is in a class of medications called cephamycin antibiotics. It works by killing bacteria.Antibiotics such as cefoxitin injection will not work for colds, flu, or other viral infections. Taking ...

  5. Tigecycline Injection

    Science.gov (United States)

    ... is in a class of medications called tetracycline antibiotics. It works by killing bacteria that cause infection.Antibiotics such as tigecycline injection will not work for colds, flu, or other viral infections. Using ...

  6. Ertapenem Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as ertapenem injection will not work for colds, flu, or other viral infections. Taking ...

  7. Ceftriaxone Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftriaxone injection will not work for colds, flu, or other viral infections.Using ...

  8. Cefepime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefepime injection will not work for colds, flu, or other viral infections. Using ...

  9. Telavancin Injection

    Science.gov (United States)

    ... is in a class of medications called lipoglycopeptide antibiotics. It works by killing bacteria that cause infection.Antibiotics such as telavancin injection will not work for colds, flu, or other viral infections. Using ...

  10. Doxycycline Injection

    Science.gov (United States)

    ... is in a class of medications called tetracycline antibiotics. It works by killing bacteria that cause infections.Antibiotics such as doxycycline injection will not work for colds, flu, or other viral infections. Taking ...

  11. Vancomycin Injection

    Science.gov (United States)

    ... is in a class of medications called glycopeptide antibiotics. It works by killing bacteria that cause infections.Antibiotics such as vancomycin injection will not work for colds, flu, or other viral infections. Taking ...

  12. Octreotide Injection

    Science.gov (United States)

    ... carton and protect it from light. Dispose of multi-dose vials of the immediate-release injection 14 ... and immediately place the medication in a safe location – one that is up and away and out ...

  13. Moxifloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using moxifloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  14. Delafloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using delafloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  15. Levofloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using levofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  16. Ciprofloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using ciprofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  17. Alirocumab Injection

    Science.gov (United States)

    ... 9 (PCSK9) inhibitor monoclonal antibodies. It works by blocking the production of LDL cholesterol in the body ... hives difficulty breathing or swallowing swelling of the face, throat, tongue, lips, and eyes Alirocumab injection may ...

  18. Evolocumab Injection

    Science.gov (United States)

    ... 9 (PCSK9) inhibitor monoclonal antibody. It works by blocking the production of LDL cholesterol in the body ... hives difficulty breathing or swallowing swelling of the face, throat, tongue, lips, and eyes Evolocumab injection may ...

  19. Acyclovir Injection

    Science.gov (United States)

    ... It is also used to treat first-time genital herpes outbreaks (a herpes virus infection that causes sores ... in the body. Acyclovir injection will not cure genital herpes and may not stop the spread of genital ...

  20. Butorphanol Injection

    Science.gov (United States)

    ... Butorphanol is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using butorphanol injection, you may experience withdrawal symptoms such as nervousness, agitation, shakiness, diarrhea, chills, ...

  1. Medical Issues: Equipment

    Science.gov (United States)

    ... Information Packets Equipment Pool Living With SMA Medical Issues Palliative Breathing Orthopedics Nutrition Equipment Daily Life At ... curesma.org > support & care > living with sma > medical issues > equipment Equipment Individuals with SMA often require a ...

  2. Semiconductor Manufacturing equipment introduction

    International Nuclear Information System (INIS)

    Im, Jong Sun

    2001-02-01

    This book deals with semiconductor manufacturing equipment. It is comprised of nine chapters, which are manufacturing process of semiconductor device, history of semiconductor manufacturing equipment, kinds and role of semiconductor manufacturing equipment, construction and method of semiconductor manufacturing equipment, introduction of various semiconductor manufacturing equipment, spots of semiconductor manufacturing, technical elements of semiconductor manufacturing equipment, road map of technology of semiconductor manufacturing equipment and semiconductor manufacturing equipment in the 21st century.

  3. Injecting drug use: Gendered risk.

    Science.gov (United States)

    Zahnow, Renee; Winstock, Adam R; Maier, Larissa J; Levy, Jay; Ferris, Jason

    2018-06-01

    Research demonstrates gender related differences in drug-use practices and risk behaviours. Females' structural vulnerability stemming from traditional gender roles and gender-power relations may enhance their propensity to experience injecting related risk. In this paper we explore gender differences in injection practices at the initiation event, during the first year of injecting and in the most recent 12-month period, to inform more effective harm reduction strategies. Data used in this study were drawn from the Global Drug Survey 2015. The study employs chi-square and logistic regression to assess gender differences in injection behaviours in a sample of current injectors residing in six global regions: North-West Europe; Southern Eastern Europe; North America. South America and Oceania. Females were more likely than males to report being injected by an intimate partner at initiation (OR = 4.4, 95%CI: 2.2-8.8), during the first year of injecting (OR = 4.8, 95% CI: 2.4-9.3) and in the most recent 12-month period (OR = 2.5, 95%CI: 1.0-6.2). Females reported greater difficulties accessing sterile equipment (X 2 (2,N = 453) = 8.2, p = 0.02) and were more likely to share injecting equipment than males (X 2 (1,N = 463) = 3.9, p = 0.05). Our findings highlight females' continued dependence on their intimate partner to administer the injection into the first year of their injecting career. Females remained more likely than males to rely on intimate partners for injection during the most recent 12-month period. Females report greater difficulties in sourcing sterile equipment and are more likely to share injecting equipment. We suggest that these findings reflect the broader social structure in which females are disempowered through traditional gender roles and the lack of gender appropriate harm reduction services. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Ceramic injection molding

    International Nuclear Information System (INIS)

    Agueda, Horacio; Russo, Diego

    1988-01-01

    Interest in making complex net-shape ceramic parts with good surface finishing and sharp tolerances without machining is a driving force for studying the injection molding technique. This method consists of softhening the ceramic material by means of adding some plastic and heating in order to inject the mixture under pressure into a relatively cold mold where solidification takes place. Essentially, it is the same process used in thermoplastic industry but, in the present case, the ceramic powder load ranges between 80 to 90 wt.%. This work shows results obtained from the fabrication of pieces of different ceramic materials (alumina, barium titanate ferrites, etc.) in a small scale, using equipments developed and constructed in the laboratory. (Author) [es

  5. Teduglutide Injection

    Science.gov (United States)

    ... who need additional nutrition or fluids from intravenous (IV) therapy. Teduglutide injection is in a class of medications ... of the ingredients.tell your doctor and pharmacist what other prescription and nonprescription medications, vitamins, nutritional supplements, and herbal products you are taking ...

  6. Dexrazoxane Injection

    Science.gov (United States)

    ... are used to treat or prevent certain side effects that may be caused by chemotherapy medications. Dexrazoxane injection (Zinecard) is used to prevent or decrease heart damage caused by doxorubicin in women who are taking the medication to treat breast cancer that has spread to other parts of the ...

  7. Triptorelin Injection

    Science.gov (United States)

    ... puberty too soon, resulting in faster than normal bone growth and development of sexual characteristics) in children 2 years and older. Triptorelin injection is in a class of medications called gonadotropin-releasing hormone (GnRH) agonists. It works by decreasing the amount ...

  8. Missed hormonal contraceptives: new recommendations.

    Science.gov (United States)

    Guilbert, Edith; Black, Amanda; Dunn, Sheila; Senikas, Vyta

    2008-11-01

    To provide evidence-based guidance for women and their health care providers on the management of missed or delayed hormonal contraceptive doses in order to prevent unintended pregnancy. Medline, PubMed, and the Cochrane Database were searched for articles published in English, from 1974 to 2007, about hormonal contraceptive methods that are available in Canada and that may be missed or delayed. Relevant publications and position papers from appropriate reproductive health and family planning organizations were also reviewed. The quality of evidence is rated using the criteria developed by the Canadian Task Force on Preventive Health Care. This committee opinion will help health care providers offer clear information to women who have not been adherent in using hormonal contraception with the purpose of preventing unintended pregnancy. The Society of Obstetricians and Gynaecologists of Canada. SUMMARY STATEMENTS: 1. Instructions for what women should do when they miss hormonal contraception have been complex and women do not understand them correctly. (I) 2. The highest risk of ovulation occurs when the hormone-free interval is prolonged for more than seven days, either by delaying the start of combined hormonal contraceptives or by missing active hormone doses during the first or third weeks of combined oral contraceptives. (II) Ovulation rarely occurs after seven consecutive days of combined oral contraceptive use. (II) RECOMMENDATIONS: 1. Health care providers should give clear, simple instructions, both written and oral, on missed hormonal contraceptive pills as part of contraceptive counselling. (III-A) 2. Health care providers should provide women with telephone/electronic resources for reference in the event of missed or delayed hormonal contraceptives. (III-A) 3. In order to avoid an increased risk of unintended pregnancy, the hormone-free interval should not exceed seven days in combined hormonal contraceptive users. (II-A) 4. Back-up contraception should

  9. Selection of equipment for equipment qualification

    International Nuclear Information System (INIS)

    Torr, K.G.

    1989-01-01

    This report describes the methodology applied in selecting equipment in the special safety systems for equipment qualification in the CANDU 600 MW nuclear generating stations at Gentilly 2 and Point Lepreau. Included is an explanation of the selection procedure adopted and the rationale behind the criteria used in identifying the equipment. The equipment items on the list have been grouped into three priority categories as a planning aid to AECB staff for a review of the qualification status of the special safety systems

  10. Droid X The Missing Manual

    CERN Document Server

    Gralla, Preston

    2011-01-01

    Get the most from your Droid X right away with this entertaining Missing Manual. Veteran tech author Preston Gralla offers a guided tour of every feature, with lots of expert tips and tricks along the way. You'll learn how to use calling and texting features, take and share photos, enjoy streaming music and video, and much more. Packed with full-color illustrations, this engaging book covers everything from getting started to advanced features and troubleshooting. Unleash the power of Motorola's hot new device with Droid X: The Missing Manual. Get organized. Import your contacts and sync wit

  11. Motorola Xoom The Missing Manual

    CERN Document Server

    Gralla, Preston

    2011-01-01

    Motorola Xoom is the first tablet to rival the iPad, and no wonder with all of the great features packed into this device. But learning how to use everything can be tricky-and Xoom doesn't come with a printed guide. That's where this Missing Manual comes in. Gadget expert Preston Gralla helps you master your Xoom with step-by-step instructions and clear explanations. As with all Missing Manuals, this book offers refreshing, jargon-free prose and informative illustrations. Use your Xoom as an e-book reader, music player, camcorder, and phoneKeep in touch with email, video and text chat, and so

  12. Ventajas del uso de la inyección electrónica para vehículos diesel pesados en las condiciones de Cuba. // Advantages of electronic injection for diesel engines in heavy duty equipment.

    Directory of Open Access Journals (Sweden)

    J. Luis Reyes González

    2002-09-01

    Full Text Available Tomando en cuenta la importancia que tiene para Cuba el obtener una eficiencia energética elevada en los motores decombustión interna, al igual que el control de las emanaciones de gases tóxicos en los mismos, se realizó este trabajo dondese demuestran las ventajas tanto en el orden económico como ecológico de los motores diesel con mando electrónico paraequipos pesados empleados en la transportación de carga por camiones en la empresa Cubalse.Por medio de métodos experimentales y estadísticos, se obtuvo el consumo de combustible y la humosidad en motores coninyección electrónica (Detroit y en motores que utilizan los métodos tradicionales (Cummins. Los rresultadosdemostraron la superioridad en ambos aspectos de los motores con inyección electrónica.Se realizó una valoración del tiempo de amortización de la inversión inicial necesaria para utilizar en el parque existenteesta novedosa técnica de la inyección electrónica.Palabras claves: Eficiencia energética, inyección electrónica, consumo de combustible, motores de combustióninterna.__________________________________________________________________Abstract.Taking into consideration the importance of achieving a high efficiency in the internal combustion engines and emissioncontrol of the exhaust gases, this paper deals with economical and environmental advantages of the electronic controlleddiesel engines in heavy-duty trucks, which are used by Cubalse in the transportation. The fuel consumption and the sootemission in Detroit motors (with electronic injection system and Cummins (with traditional system, were studied usingstatistic and experimental methods, and the Detroit proved to be superior in both parameters. The pay back time for theinvestment needed to change the systems of all the existent trucks were calculatedKey words: Energetic efficiency, electronic injection, fuel consumption, internal combustion engine.

  13. Did you miss the eclipse?

    CERN Multimedia

    CERN Bulletin

    2015-01-01

    Not wanting to miss a moment of the beautiful celestial dance that played out on Friday, 20 March, Jens Roder of CERN’s PH group took to the Jura mountains, where he got several shots of the event. Here are a selection of his photos, which he was kind enough to share with the Bulletin and its readers.  

  14. Missing Boxes in Central Europe

    DEFF Research Database (Denmark)

    Prockl, Günter; Weibrecht Kristensen, Kirsten

    2015-01-01

    The Chinese New Year is an event that obviously happens every year. Every year however it also causes severe problems for the companies involved in the industry in form of missing containers throughout the chain but in particular in the European Hinterland. Illustrated on the symptoms of the Chin...

  15. Perfil de los usuarios de drogas por vía parenteral que mantienen conductas de riesgo relacionadas con la inyección en Cataluña Characteristics of intravenous drug users who share injection equipment in Catalonia (Spain

    Directory of Open Access Journals (Sweden)

    Cinta Folch

    2012-02-01

    between 2008 and 2009 in harm reduction centers. Behavioral data were collected using anonymous questionnaires administered by trained interviewers. Results: Of the 748 respondents, 31.5% had shared syringes at least once in the previous 6 months and 55.2% reported sharing injection paraphernalia (spoons, water, filters. A higher risk of syringe sharing was found among IDUs who injected daily (OR=1.5, injected cocaine (OR=1.6, had less than half their supply of syringes from a free source (OR=2.5, had an IDU sexual partner (OR=1.8 or who reported indirect sharing (OR=4.1. A higher risk of indirect sharing was found in respondents who had an illegal source of income (OR=1.5, injected daily (OR=1, 5, injected cocaine (OR=1.4, reported sharing syringes (OR=3.9, or who reported a previous overdose (OR=1.5. Conclusions: Despite the widespread use of harm reduction programs in Catalonia, a significant proportion of IDUs continue to practise injection-related risk behaviors. Further reductions in risk behaviors could be achieved by improving access to all sterile injecting equipment, especially among cocaine injectors and IDUs who inject frequently, and by including IDU sexual partners within the current network of harm reduction centers.

  16. Compressed air injection technique to standardize block injection pressures.

    Science.gov (United States)

    Tsui, Ban C H; Li, Lisa X Y; Pillay, Jennifer J

    2006-11-01

    Presently, no standardized technique exists to monitor injection pressures during peripheral nerve blocks. Our objective was to determine if a compressed air injection technique, using an in vitro model based on Boyle's law and typical regional anesthesia equipment, could consistently maintain injection pressures below a 1293 mmHg level associated with clinically significant nerve injury. Injection pressures for 20 and 30 mL syringes with various needle sizes (18G, 20G, 21G, 22G, and 24G) were measured in a closed system. A set volume of air was aspirated into a saline-filled syringe and then compressed and maintained at various percentages while pressure was measured. The needle was inserted into the injection port of a pressure sensor, which had attached extension tubing with an injection plug clamped "off". Using linear regression with all data points, the pressure value and 99% confidence interval (CI) at 50% air compression was estimated. The linearity of Boyle's law was demonstrated with a high correlation, r = 0.99, and a slope of 0.984 (99% CI: 0.967-1.001). The net pressure generated at 50% compression was estimated as 744.8 mmHg, with the 99% CI between 729.6 and 760.0 mmHg. The various syringe/needle combinations had similar results. By creating and maintaining syringe air compression at 50% or less, injection pressures will be substantially below the 1293 mmHg threshold considered to be an associated risk factor for clinically significant nerve injury. This technique may allow simple, real-time and objective monitoring during local anesthetic injections while inherently reducing injection speed.

  17. Miss Julie: A Psychoanalytic Study

    Directory of Open Access Journals (Sweden)

    Sonali Jain

    2015-10-01

    Full Text Available Sigmund Freud theorized that ‘the hero of the tragedy must suffer…to bear the burden of tragic guilt…(that lay in rebellion against some divine or human authority.’ August Strindberg, the Swedish poet, playwright, author and visual artist, like Shakespeare before him, portrayed insanity as the ultimate of tragic conflict. In this paper I seek to explore and reiterate the dynamics of human relationships that are as relevant today as they were in Strindberg’s time. I propose to examine Strindberg’s Miss Julie, a play set in nineteenth century Sweden, through a psychoanalytic lens. The play deals with bold themes of class and sexual identity politics. Notwithstanding the progress made in breaking down gender barriers, the inequalities inherent in a patriarchal system persist in modern society. Miss Julie highlights these imbalances. My analysis of the play deals with issues of culture and psyche, and draws on Freud, Melanie Klein, Lacan, Luce Irigaray and other contemporary feminists. Miss Julie is a discourse on hysteria, which is still pivotal to psychoanalysis. Prominent philosophers like Hegel and the psychoanalyst Jacques Lacan have written about the dialectic of the master and the slave – a relationship that is characterized by dependence, demand and cruelty. The history of human civilization shows beyond any doubt that there is an intimate connection between cruelty and the sexual instinct. An analysis of the text is carried out using the sado-masochistic dynamic as well the slave-master discourse. I argue that Miss Julie subverts the slave-master relationship. The struggle for dominance and power is closely linked with the theme of sexuality in the unconscious. To quote the English actor and director Alan Rickman, ‘Watching or working on the plays of Strindberg is like seeing the skin, flesh and bones of life separated from each other. Challenging and timeless.’

  18. Methods for Mediation Analysis with Missing Data

    Science.gov (United States)

    Zhang, Zhiyong; Wang, Lijuan

    2013-01-01

    Despite wide applications of both mediation models and missing data techniques, formal discussion of mediation analysis with missing data is still rare. We introduce and compare four approaches to dealing with missing data in mediation analysis including list wise deletion, pairwise deletion, multiple imputation (MI), and a two-stage maximum…

  19. Wrist arthrography: The value of the three compartment injection technique

    Energy Technology Data Exchange (ETDEWEB)

    Levinsohn, E.M.; Coren, A.B.; Palmer, A.K.; Zinberg, E.

    1987-10-01

    Arthrography of the wrist was performed on 50 consecutive patients with obscure post-traumatic wrist pain by injecting contrast separately into the radiocarpal joint, midcarpal compartment, and distal radioulnar joint. When distal radioulnar joint and midcarpal compartment injections were added to the standard radiocarpal injection, many significant unsuspected abnormalities were identified. Of the 25 triangular fibrocartilage complex abnormalities identified, six (24%) were found only with the distal radioulnar joint injection. Of the 29 abnormal communications between the midcarpal compartment and the radiocarpal joint, ten (35%) were found only with the midcarpal injection. Similarly, five of 29 (17%) of the abnormal radiocarpal-midcarpal communications would have been missed if a midcarpal injection alone had been performed. These findings indicate that separate injections into the radiocarpal joint, midcarpal compartment, and distal radioulnar joint are needed to identify a large number of abnormalities not seen with injections into one compartment alone.

  20. The 50 million missing women.

    Science.gov (United States)

    Allahbadia, Gautam N

    2002-09-01

    The epidemic of gender selection is ravaging countries like India & China. Approximately fifty million women are "missing" in the Indian population. Generally three principle causes are given: female infanticide, better food and health care for boys and maternal death at childbirth. Prenatal sex determination and the abortion of female fetuses threatens to skew the sex ratio to new highs. Estimates of the number of female fetuses being destroyed every year in India vary from two million to five million. This review from India attempts to summarize all the currently available methods of sex selection and also highlights the current medical practice regards the subject in south-east Asia.

  1. Measurement of Missing Tranverse Energy

    CERN Document Server

    The ATLAS Collaboration

    2009-01-01

    This note discusses the overall ATLAS detector performance for the reconstruction of the missing transverse energy, ETmiss. Two reconstruction algorithms are discussed and their performance is evaluated for a variety of simulated physics processes which probe different topologies and different total transverse energy regimes. In addition, effects of fake ETmiss, resulting from instrumental effects and from false reconstructions are investigated. Finally, studies with first data, corresponding to an integrated luminosity of 100 pb-1, are suggested which can be used to assess and calibrate the ETmiss performance at the startup of data taking.

  2. Bayes reconstruction of missing teeth

    DEFF Research Database (Denmark)

    Sporring, Jon; Jensen, Katrine Hommelhoff

    2008-01-01

    contains two major parts: A statistical model of a selection of tooth shapes and a reconstruction of missing data. We use a training set consisting of 3D scans of dental cast models obtained with a laser scanner, and we have build a model of the shape variability of the teeth, their neighbors...... or equivalently noise elimination and for data analysis. However for small sets of high dimensional data, the log-likelihood estimator for the covariance matrix is often far from convergence, and therefore reliable models must be obtained by use of prior information. We propose a natural and intrinsic...

  3. Windows 7 The Missing Manual

    CERN Document Server

    Pogue, David

    2010-01-01

    In early reviews, geeks raved about Windows 7. But if you're an ordinary mortal, learning what this new system is all about will be challenging. Fear not: David Pogue's Windows 7: The Missing Manual comes to the rescue. Like its predecessors, this book illuminates its subject with reader-friendly insight, plenty of wit, and hardnosed objectivity for beginners as well as veteran PC users. Windows 7 fixes many of Vista's most painful shortcomings. It's speedier, has fewer intrusive and nagging screens, and is more compatible with peripherals. Plus, Windows 7 introduces a slew of new features,

  4. Are there missing convective currents?

    International Nuclear Information System (INIS)

    Chen, C.Y.

    1992-01-01

    It is revealed in this letter that as far as distribution functions obtained from gyrokinetic equations are concerned, the standard formulae to evaluate currents in plasmas are not applicable due to the fact that those distribution functions are given in a moving coordinate frame and the moving is essentially related to perturbed fields. With heuristic and analytic approaches, appropriate formulae are obtained to evaluate several types of currents in plasmas of which some have been missing in previous approaches. (author). 6 refs, 1 fig

  5. What We’re Missing

    OpenAIRE

    Camille R. Whitney; Jing Liu

    2017-01-01

    For schools and teachers to help students develop knowledge and skills, students need to show up to class. Yet absenteeism is prevalent, especially in secondary schools. This study uses a rich data set tracking class attendance by day for over 50,000 middle and high school students from an urban district in academic years 2007–2008 through 2012–2013. Our results extend and modify the extant findings on absenteeism that have been based almost exclusively on full-day absenteeism, missing class-...

  6. Shipboard and laboratory equipment

    Digital Repository Service at National Institute of Oceanography (India)

    Shyamprasad, M.; Ramaswamy, V.

    The polymetallic nodules occur at an average depth of 4500 m. Adequate equipment and techniques are required for the exploration at such depths. Shipboard and various laboratory equipments for the sampling of polymetallic nodules is described...

  7. Remote handling equipment

    International Nuclear Information System (INIS)

    Clement, G.

    1984-01-01

    After a definition of intervention, problems encountered for working in an adverse environment are briefly analyzed for development of various remote handling equipments. Some examples of existing equipments are given [fr

  8. Exercise Equipment: Neutral Buoyancy

    Science.gov (United States)

    Shackelford, Linda; Valle, Paul

    2016-01-01

    Load Bearing Equipment for Neutral Buoyancy (LBE-NB) is an exercise frame that holds two exercising subjects in position as they apply counter forces to each other for lower extremity and spine loading resistance exercises. Resistance exercise prevents bone loss on ISS, but the ISS equipment is too massive for use in exploration craft. Integrating the human into the load directing, load generating, and motion control functions of the exercise equipment generates safe exercise loads with less equipment mass and volume.

  9. BP volume reduction equipment

    International Nuclear Information System (INIS)

    Kitamura, Yoshinori; Muroo, Yoji; Hamanaka, Isao

    2003-01-01

    A new type of burnable poison (BP) volume reduction system is currently being developed. Many BP rods, a subcomponent of spent fuel assemblies are discharged from nuclear power reactors. This new system reduces the overall volume of BP rods. The main system consists of BP rod cutting equipment, equipment for the recovery of BP cut pieces, and special transport equipment for the cut rods. The equipment is all operated by hydraulic press cylinders in water to reduce operator exposure to radioactivity. (author)

  10. Individual Information-Centered Approach for Handling Physical Activity Missing Data

    Science.gov (United States)

    Kang, Minsoo; Rowe, David A.; Barreira, Tiago V.; Robinson, Terrance S.; Mahar, Matthew T.

    2009-01-01

    The purpose of this study was to validate individual information (II)-centered methods for handling missing data, using data samples of 118 middle-aged adults and 91 older adults equipped with Yamax SW-200 pedometers and Actigraph accelerometers for 7 days. We used a semisimulation approach to create six data sets: three physical activity outcome…

  11. Missing mass of the Universe

    International Nuclear Information System (INIS)

    Mazure, A.

    1989-01-01

    The first evidence for missing mass or dark matter comes from the 30's. On one hand, Oort noted that in the solar neighbourhood the mass of the stars (inferred from count numbers) cannot account for their observed velocities. On the other hand, observation on the sky of various galaxy condensations like the Coma cluster let suppose that they are actual bound systems and not only statistical fluctuations. However, with such an assumption, Zwicky concluded that the velocity dispersion of galaxies in Coma required 100 times more mass than contained in galaxies. Since this period, refined observations, analyses and a reevaluation of the cosmic distance scale reduced this factor but the problem is still present. It is particularly striking for spiral galaxies where systematic observations of rotation curves lead to infer the presence of spherical massive halos. These dynamical evidences form the first missing mass problem. The second one appears with the development of Great Unified Theories for which the natural laboratory is the very early Universe. A consequence of these theories is that our Universe could be closed by exotic particles which interact only gravitationally [fr

  12. Electrical equipment qualification

    International Nuclear Information System (INIS)

    Farmer, W.S.

    1983-01-01

    Electrical equipment qualification research programs being carried out by CEA, JAERI, and Sandia Laboratories are discussed. Objectives of the program are: (1) assessment of accident simulation methods for electrical equipment qualification testing; lower coarse (2) evaluation of equipment aging and accelerated aging methods; (3) determine radiation dose spectrum to electrical equipment and assess simulation methods for qualification; (4) identify inadequacies in electrical equipment qualification procedures and standards and potential failure modes; and (5) provide data for verifying and improving standards, rules and regulatory guides

  13. Space Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.

    1998-01-01

    The performance evaluation of space heating equipment for a geothermal application is generally considered from either of two perspectives: (a) selecting equipment for installation in new construction, or (b) evaluating the performance and retrofit requirements of an existing system. With regard to new construction, the procedure is relatively straightforward. Once the heating requirements are determined, the process need only involve the selection of appropriately sized hot water heating equipment based on the available water temperature. It is important to remember that space heating equipment for geothermal applications is the same equipment used in non-geothermal applications. What makes geothermal applications unique is that the equipment is generally applied at temperatures and flow rates that depart significantly from traditional heating system design. This chapter presents general considerations for the performance of heating equipment at non-standard temperature and flow conditions, retrofit of existing systems, and aspects of domestic hot water heating.

  14. Renewal of radiological equipment.

    Science.gov (United States)

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a

  15. Time Series Forecasting with Missing Values

    OpenAIRE

    Shin-Fu Wu; Chia-Yung Chang; Shie-Jue Lee

    2015-01-01

    Time series prediction has become more popular in various kinds of applications such as weather prediction, control engineering, financial analysis, industrial monitoring, etc. To deal with real-world problems, we are often faced with missing values in the data due to sensor malfunctions or human errors. Traditionally, the missing values are simply omitted or replaced by means of imputation methods. However, omitting those missing values may cause temporal discontinuity. Imputation methods, o...

  16. HTML5 The Missing Manual

    CERN Document Server

    MacDonald, Matthew

    2011-01-01

    HTML5 is more than a markup language-it's a dozen independent web standards all rolled into one. Until now, all it's been missing is a manual. With this thorough, jargon-free guide, you'll learn how to build web apps that include video tools, dynamic drawings, geolocation, offline web apps, drag-and-drop, and many other features. HTML5 is the future of the Web, and with this book you'll reach it quickly. The important stuff you need to know: Structure web pages in a new way. Learn how HTML5 helps make web design tools and search engines work smarter.Add audio and video without plugins. Build

  17. Integrative missing value estimation for microarray data.

    Science.gov (United States)

    Hu, Jianjun; Li, Haifeng; Waterman, Michael S; Zhou, Xianghong Jasmine

    2006-10-12

    Missing value estimation is an important preprocessing step in microarray analysis. Although several methods have been developed to solve this problem, their performance is unsatisfactory for datasets with high rates of missing data, high measurement noise, or limited numbers of samples. In fact, more than 80% of the time-series datasets in Stanford Microarray Database contain less than eight samples. We present the integrative Missing Value Estimation method (iMISS) by incorporating information from multiple reference microarray datasets to improve missing value estimation. For each gene with missing data, we derive a consistent neighbor-gene list by taking reference data sets into consideration. To determine whether the given reference data sets are sufficiently informative for integration, we use a submatrix imputation approach. Our experiments showed that iMISS can significantly and consistently improve the accuracy of the state-of-the-art Local Least Square (LLS) imputation algorithm by up to 15% improvement in our benchmark tests. We demonstrated that the order-statistics-based integrative imputation algorithms can achieve significant improvements over the state-of-the-art missing value estimation approaches such as LLS and is especially good for imputing microarray datasets with a limited number of samples, high rates of missing data, or very noisy measurements. With the rapid accumulation of microarray datasets, the performance of our approach can be further improved by incorporating larger and more appropriate reference datasets.

  18. Integrative missing value estimation for microarray data

    Directory of Open Access Journals (Sweden)

    Zhou Xianghong

    2006-10-01

    Full Text Available Abstract Background Missing value estimation is an important preprocessing step in microarray analysis. Although several methods have been developed to solve this problem, their performance is unsatisfactory for datasets with high rates of missing data, high measurement noise, or limited numbers of samples. In fact, more than 80% of the time-series datasets in Stanford Microarray Database contain less than eight samples. Results We present the integrative Missing Value Estimation method (iMISS by incorporating information from multiple reference microarray datasets to improve missing value estimation. For each gene with missing data, we derive a consistent neighbor-gene list by taking reference data sets into consideration. To determine whether the given reference data sets are sufficiently informative for integration, we use a submatrix imputation approach. Our experiments showed that iMISS can significantly and consistently improve the accuracy of the state-of-the-art Local Least Square (LLS imputation algorithm by up to 15% improvement in our benchmark tests. Conclusion We demonstrated that the order-statistics-based integrative imputation algorithms can achieve significant improvements over the state-of-the-art missing value estimation approaches such as LLS and is especially good for imputing microarray datasets with a limited number of samples, high rates of missing data, or very noisy measurements. With the rapid accumulation of microarray datasets, the performance of our approach can be further improved by incorporating larger and more appropriate reference datasets.

  19. Injection Laryngoplasty Materials

    OpenAIRE

    Haldun Oðuz

    2013-01-01

    Injection laryngoplasty is one of the treatment options for voice problems. In the recent years, more safe and more biocompatible injection materials are available on the market. Long and short term injection materials are discussed in this review.

  20. Penicillin G Procaine Injection

    Science.gov (United States)

    Penicillin G procaine injection is used to treat certain infections caused by bacteria. Penicillin G procaine injection should not be used to ... early in the treatment of certain serious infections. Penicillin G procaine injection is in a class of ...

  1. RETRIEVAL EQUIPMENT DESCRIPTIONS

    International Nuclear Information System (INIS)

    J. Steinhoff

    1997-01-01

    The objective and the scope of this document are to list and briefly describe the major mobile equipment necessary for waste package (WP) retrieval from the proposed subsurface nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the equipment are explained and summarized in the individual subsections of this document. There are no quality assurance requirements or QA controls in this document. Retrieval under normal conditions is accomplished with the same fleet of equipment as is used for emplacement. Descriptions of equipment used for retrieval under normal conditions is found in Emplacement Equipment Descriptions, DI: BCAF00000-01717-5705-00002 (a document in progress). Equipment used for retrieval under abnormal conditions is addressed in this document and consists of the following: (1) Inclined Plane Hauler; (2) Bottom Lift Transporter; (3) Load Haul Dump (LHD) Loader; (4) Heavy Duty Forklift for Emplacement Drifts; (5) Covered Shuttle Car; (6) Multipurpose Vehicle; and (7) Scaler

  2. Medical equipment management

    CERN Document Server

    Willson, Keith; Tabakov, Slavik

    2013-01-01

    Know What to Expect When Managing Medical Equipment and Healthcare Technology in Your Organization As medical technology in clinical care becomes more complex, clinical professionals and support staff must know how to keep patients safe and equipment working in the clinical environment. Accessible to all healthcare professionals and managers, Medical Equipment Management presents an integrated approach to managing medical equipment in healthcare organizations. The book explains the underlying principles and requirements and raises awareness of what needs to be done and what questions to ask. I

  3. Data communication equipment

    International Nuclear Information System (INIS)

    Kim, Hak Seon; Lee, Sang Mok

    1998-02-01

    The contents of this book are introduction of data communication on definition, purpose and history, information terminal about data communication system and data transmission system, data transmit equipment of summary, transmission cable, data port, concentrator and front-end processor, audio communication equipment like phones, radio communication equipment of summary on foundation of electromagnetic waves, AM transmitter, AM receiver, FM receiver and FM transmitter, a satellite and mobile communication equipment such as earth station, TT and C and Cellular phone, video telephone and new media apparatus.

  4. A Review of Methods for Missing Data.

    Science.gov (United States)

    Pigott, Therese D.

    2001-01-01

    Reviews methods for handling missing data in a research study. Model-based methods, such as maximum likelihood using the EM algorithm and multiple imputation, hold more promise than ad hoc methods. Although model-based methods require more specialized computer programs and assumptions about the nature of missing data, these methods are appropriate…

  5. Methods for Handling Missing Secondary Respondent Data

    Science.gov (United States)

    Young, Rebekah; Johnson, David

    2013-01-01

    Secondary respondent data are underutilized because researchers avoid using these data in the presence of substantial missing data. The authors reviewed, evaluated, and tested solutions to this problem. Five strategies of dealing with missing partner data were reviewed: (a) complete case analysis, (b) inverse probability weighting, (c) correction…

  6. Student versus Faculty Perceptions of Missing Class.

    Science.gov (United States)

    Sleigh, Merry J.; Ritzer, Darren R.; Casey, Michael B.

    2002-01-01

    Examines and compares student and faculty attitudes towards students missing classes and class attendance. Surveys undergraduate students (n=231) in lower and upper level psychology courses and psychology faculty. Reports that students found more reasons acceptable for missing classes and that the amount of in-class material on the examinations…

  7. Methods to Minimize Zero-Missing Phenomenon

    DEFF Research Database (Denmark)

    da Silva, Filipe Miguel Faria; Bak, Claus Leth; Gudmundsdottir, Unnur Stella

    2010-01-01

    With the increasing use of high-voltage AC cables at transmission levels, phenomena such as current zero-missing start to appear more often in transmission systems. Zero-missing phenomenon can occur when energizing cable lines with shunt reactors. This may considerably delay the opening of the ci...

  8. HIV and Injection Drug Use PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    This 60 second public service announcement is based on the December 2016 CDC Vital Signs report. Sharing needles, syringes, and other injection equipment puts you at risk for getting HIV and other infections, including hepatitis. Learn how to reduce your HIV risk.

  9. Cooling of electronic equipment

    DEFF Research Database (Denmark)

    A. Kristensen, Anders Schmidt

    2003-01-01

    Cooling of electronic equipment is studied. The design size of electronic equipment decrease causing the thermal density to increase. This affect the cooling which can cause for example failures of critical components due to overheating or thermal induced stresses. Initially a pin fin heat sink...

  10. Capital Equipment Replacement Decisions

    OpenAIRE

    Batterham, Robert L.; Fraser, K.I.

    1995-01-01

    This paper reviews the literature on the optimal replacement of capital equipment, especially farm machinery. It also considers the influence of taxation and capital rationing on replacement decisions. It concludes that special taxation provisions such as accelerated depreciation and investment allowances are unlikely to greatly influence farmers' capital equipment replacement decisions in Australia.

  11. Missed opportunities in child healthcare

    Directory of Open Access Journals (Sweden)

    Linda Jonker

    2014-08-01

    Objectives: This article describes the experiences of mothers that utilised comprehensive child health services in the Cape Metropolitan area of South Africa. Services included treatment for diseases; preventative interventions such as immunisation; and promotive interventions, such as improvement in nutrition and promotion of breastfeeding. Method: A qualitative, descriptive phenomenological approach was applied to explore the experiences and perceptions of mothers and/or carers utilising child healthcare services. Thirty percent of the clinics were selected purposively from the total population. A convenience purposive non-probability sampling method was applied to select 17 mothers who met the criteria and gave written consent. Interviews were conducted and recorded digitally using an interview guide. The data analysis was done using Tesch’s eight step model. Results: Findings of the study indicated varied experiences. Not all mothers received information about the Road to Health book or card. According to the mothers, integrated child healthcare services were not practised. The consequences were missed opportunities in immunisation, provision of vitamin A, absence of growth monitoring, feeding assessment and provision of nutritional advice. Conclusion: There is a need for simple interventions such as oral rehydration, early recognition and treatment of diseases, immunisation, growth monitoring and appropriate nutrition advice. These services were not offered diligently. Such interventions could contribute to reducing the incidence of child morbidity and mortality.

  12. Layout considerations for the PSB H- injection system

    CERN Document Server

    Aiba, M; Carli, C; Chanel, M; Fowler, A; Goddard, B; Weterings, W

    2009-01-01

    The layout of the PSB H- injection system is described, including the arguments for the geometry and the required equipment performance parameters. The longitudinal positions of the main elements are specified, together with the injected and circulating beam axes. The assumptions used in determining the geometry are listed.

  13. Injection safety practices among nursing staff of mission hospitals in ...

    African Journals Online (AJOL)

    Vincent E. Omorogbe, Vivian O. Omuemu, Alphonsus R. Isara ... practice of injection safety by nurses in mission hospitals in Benin City, Nigeria. Materials and Methods: A descriptive cross-sectional study was carried out. .... alternatives, reuse of injection equipment, self ... health facilities in rendering healthcare services.

  14. Detailed modeling of common rail fuel injection process

    NARCIS (Netherlands)

    Seykens, X.L.J.; Somers, L.M.T.; Baert, R.S.G.

    2005-01-01

    Modeling of fuel injection equipment is a tool that is used increasingly for explaining or predicting the effect of advanced diesel injection strategies on combustion and emissions. This paper reports on the modeling of the high-pressure part of a research type Heavy Duty Common Rail (CR) fuel

  15. Missed opportunities in child healthcare

    Directory of Open Access Journals (Sweden)

    Linda Jonker

    2014-01-01

    Full Text Available Background: Various policies in health, such as Integrated Management of Childhood Illnesses, were introduced to enhance integrated service delivery in child healthcare. During clinical practice the researcher observed that integrated services may not be rendered.Objectives: This article describes the experiences of mothers that utilised comprehensive child health services in the Cape Metropolitan area of South Africa. Services included treatment for diseases; preventative interventions such as immunisation; and promotive interventions, such as improvement in nutrition and promotion of breastfeeding.Method: A qualitative, descriptive phenomenological approach was applied to explore the experiences and perceptions of mothers and/or carers utilising child healthcare services. Thirty percent of the clinics were selected purposively from the total population. A convenience purposive non-probability sampling method was applied to select 17 mothers who met the criteria and gave written consent. Interviews were conducted and recorded digitally using an interview guide. The data analysis was done using Tesch’s eight step model.Results: Findings of the study indicated varied experiences. Not all mothers received information about the Road to Health book or card. According to the mothers, integrated child healthcare services were not practised. The consequences were missed opportunities in immunisation, provision of vitamin A, absence of growth monitoring, feeding assessment and provision of nutritional advice.Conclusion: There is a need for simple interventions such as oral rehydration, early recognition and treatment of diseases, immunisation, growth monitoring and appropriate nutrition advice. These services were not offered diligently. Such interventions could contribute to reducing the incidence of child morbidity and mortality.

  16. Creating Web Sites The Missing Manual

    CERN Document Server

    MacDonald, Matthew

    2006-01-01

    Think you have to be a technical wizard to build a great web site? Think again. For anyone who wants to create an engaging web site--for either personal or business purposes--Creating Web Sites: The Missing Manual demystifies the process and provides tools, techniques, and expert guidance for developing a professional and reliable web presence. Like every Missing Manual, you can count on Creating Web Sites: The Missing Manual to be entertaining and insightful and complete with all the vital information, clear-headed advice, and detailed instructions you need to master the task at hand. Autho

  17. Scalable Tensor Factorizations with Missing Data

    DEFF Research Database (Denmark)

    Acar, Evrim; Dunlavy, Daniel M.; Kolda, Tamara G.

    2010-01-01

    of missing data, many important data sets will be discarded or improperly analyzed. Therefore, we need a robust and scalable approach for factorizing multi-way arrays (i.e., tensors) in the presence of missing data. We focus on one of the most well-known tensor factorizations, CANDECOMP/PARAFAC (CP...... is shown to successfully factor tensors with noise and up to 70% missing data. Moreover, our approach is significantly faster than the leading alternative and scales to larger problems. To show the real-world usefulness of CP-WOPT, we illustrate its applicability on a novel EEG (electroencephalogram...

  18. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... Background: Of the estimated 384,000 needle-stick injuries occurring in hospitals each year, 23% occur in surgical settings. This study was conducted to assess safe injection procedures, injection practices, and circumstances contributing to needlestick and sharps injures (NSSIs) in operating rooms.

  19. HVAC systems and equipment

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, S.T. (Linford Air and Refrigeration Company, Oakland, CA (US))

    1990-02-01

    The author discusses the section of the ASHRAE Standard 90.1-1989 which addresses HVAC systems and equipment. New features of HVAC systems mandatory general requirements are described. New prescriptive requirements are detailed.

  20. Personal Protective Equipment

    National Research Council Canada - National Science Library

    1998-01-01

    ... of personal protective equipment A safety program for new employees is a necessary part of any orientation program An on-going safety program should be used to motivate employees to continue to use...

  1. Electronic equipment packaging technology

    CERN Document Server

    Ginsberg, Gerald L

    1992-01-01

    The last twenty years have seen major advances in the electronics industry. Perhaps the most significant aspect of these advances has been the significant role that electronic equipment plays in almost all product markets. Even though electronic equipment is used in a broad base of applications, many future applications have yet to be conceived. This versatility of electron­ ics has been brought about primarily by the significant advances that have been made in integrated circuit technology. The electronic product user is rarely aware of the integrated circuits within the equipment. However, the user is often very aware of the size, weight, mod­ ularity, maintainability, aesthetics, and human interface features of the product. In fact, these are aspects of the products that often are instrumental in deter­ mining its success or failure in the marketplace. Optimizing these and other product features is the primary role of Electronic Equipment Packaging Technology. As the electronics industry continues to pr...

  2. CV equipment responsibilities

    CERN Document Server

    Pirollet, B

    2008-01-01

    This document describes the limits of the responsibilities of the TS/CV for fire fighting equipment at the LHC. The various interfaces, providers and users of the water supply systems and clean water raising systems are described.

  3. Equipment for hydraulic testing

    International Nuclear Information System (INIS)

    Jacobsson, L.; Norlander, H.

    1981-07-01

    Hydraulic testing in boreholes is one major task of the hydrogeological program in the Stripa Project. A new testing equipment for this purpose was constructed. It consists of a downhole part and a surface part. The downhole part consists of two packers enclosing two test-sections when inflated; one between the packers and one between the bottom packer and the bottom of the borehole. A probe for downhole electronics is also included in the downhole equipment together with electrical cable and nylon tubing. In order to perform shut-in and pulse tests with high accuracy a surface controlled downhole valve was constructed. The surface equipment consists of the data acquisition system, transducer amplifier and surface gauges. In the report detailed descriptions of each component in the whole testing equipment are given. (Auth.)

  4. The prevention and handling of the missing data

    OpenAIRE

    Kang, Hyun

    2013-01-01

    Even in a well-designed and controlled study, missing data occurs in almost all research. Missing data can reduce the statistical power of a study and can produce biased estimates, leading to invalid conclusions. This manuscript reviews the problems and types of missing data, along with the techniques for handling missing data. The mechanisms by which missing data occurs are illustrated, and the methods for handling the missing data are discussed. The paper concludes with recommendations for ...

  5. Maternal death and near miss measurement

    African Journals Online (AJOL)

    ABEOLUGBENGAS

    2008-05-26

    May 26, 2008 ... Maternal health services need to be accountable more than ever ... of maternal death and near miss audit, surveillance and review is ..... (d) A fundamental principle of these ..... quality assurance in obstetrics in Nigeria - a.

  6. Clustering with Missing Values: No Imputation Required

    Science.gov (United States)

    Wagstaff, Kiri

    2004-01-01

    Clustering algorithms can identify groups in large data sets, such as star catalogs and hyperspectral images. In general, clustering methods cannot analyze items that have missing data values. Common solutions either fill in the missing values (imputation) or ignore the missing data (marginalization). Imputed values are treated as just as reliable as the truly observed data, but they are only as good as the assumptions used to create them. In contrast, we present a method for encoding partially observed features as a set of supplemental soft constraints and introduce the KSC algorithm, which incorporates constraints into the clustering process. In experiments on artificial data and data from the Sloan Digital Sky Survey, we show that soft constraints are an effective way to enable clustering with missing values.

  7. Missed medical appointment among hypertensive and diabetic ...

    African Journals Online (AJOL)

    Keywords: Missed medical appointments, Hypertensive, Diabetic outpatients, Medication adherence, ... 12 weeks, at 95 % confidence level and 5 % error margin, 300 hypertensive ... monthly income and health insurance status of respondents ...

  8. Missed Radiation Therapy and Cancer Recurrence

    Science.gov (United States)

    Patients who miss radiation therapy sessions during cancer treatment have an increased risk of their disease returning, even if they eventually complete their course of radiation treatment, according to a new study.

  9. Bioinspired Computational Approach to Missing Value Estimation

    Directory of Open Access Journals (Sweden)

    Israel Edem Agbehadji

    2018-01-01

    Full Text Available Missing data occurs when values of variables in a dataset are not stored. Estimating these missing values is a significant step during the data cleansing phase of a big data management approach. The reason of missing data may be due to nonresponse or omitted entries. If these missing data are not handled properly, this may create inaccurate results during data analysis. Although a traditional method such as maximum likelihood method extrapolates missing values, this paper proposes a bioinspired method based on the behavior of birds, specifically the Kestrel bird. This paper describes the behavior and characteristics of the Kestrel bird, a bioinspired approach, in modeling an algorithm to estimate missing values. The proposed algorithm (KSA was compared with WSAMP, Firefly, and BAT algorithm. The results were evaluated using the mean of absolute error (MAE. A statistical test (Wilcoxon signed-rank test and Friedman test was conducted to test the performance of the algorithms. The results of Wilcoxon test indicate that time does not have a significant effect on the performance, and the quality of estimation between the paired algorithms was significant; the results of Friedman test ranked KSA as the best evolutionary algorithm.

  10. Sodium Ferric Gluconate Injection

    Science.gov (United States)

    Sodium ferric gluconate injection is used to treat iron-deficiency anemia (a lower than normal number of ... are also receiving the medication epoetin (Epogen, Procrit). Sodium ferric gluconate injection is in a class of ...

  11. Calcitonin Salmon Injection

    Science.gov (United States)

    Calcitonin salmon injection is used to treat osteoporosis in postmenopausal women. Osteoporosis is a disease that causes bones to weaken and break more easily. Calcitonin salmon injection is also used to treat Paget's disease ...

  12. Iron Dextran Injection

    Science.gov (United States)

    Iron dextran injection is used to treat iron-deficiency anemia (a lower than normal number of red blood cells ... treated with iron supplements taken by mouth. Iron dextran injection is in a class of medications called ...

  13. Aminocaproic Acid Injection

    Science.gov (United States)

    Aminocaproic acid injection is used to control bleeding that occurs when blood clots are broken down too quickly. This ... the baby is ready to be born). Aminocaproic acid injection is also used to control bleeding in ...

  14. Deoxycholic Acid Injection

    Science.gov (United States)

    Deoxycholic acid injection is used to improve the appearance and profile of moderate to severe submental fat ('double chin'; fatty tissue located under the chin). Deoxycholic acid injection is in a class of medications called ...

  15. Cluster beam injection

    International Nuclear Information System (INIS)

    Bottiglioni, F.; Coutant, J.; Fois, M.

    1978-01-01

    Areas of possible applications of cluster injection are discussed. The deposition inside the plasma of molecules, issued from the dissociation of the injected clusters, has been computed. Some empirical scaling laws for the penetration are given

  16. Antigen injection (image)

    Science.gov (United States)

    Leprosy is caused by the organism Mycobacterium leprae . The leprosy test involves injection of an antigen just under ... if your body has a current or recent leprosy infection. The injection site is labeled and examined ...

  17. Gender differences in sexual and injection risk behavior among active young injection drug users in San Francisco (the UFO Study).

    Science.gov (United States)

    Evans, Jennifer L; Hahn, Judith A; Page-Shafer, Kimberly; Lum, Paula J; Stein, Ellen S; Davidson, Peter J; Moss, Andrew R

    2003-03-01

    Female injection drug users (IDUs) represent a large proportion of persons infected with HIV in the United States, and women who inject drugs have a high incidence of hepatitis B virus (HBV) and hepatitis C virus (HCV) infection. Therefore, it is important to understand the role of gender in injection risk behavior and the transmission of blood-borne virus. In 2000-2002, 844 young (<30 years old) IDUs were surveyed in San Francisco. We compared self-reported risk behavior between 584 males and 260 female participants from cross-sectional baseline data. We used logistic regression to determine whether demographic, structural, and relationship variables explained increased needle borrowing, drug preparation equipment sharing, and being injected by another IDU among females compared to males. Females were significantly younger than males and were more likely to engage in needle borrowing, ancillary equipment sharing, and being injected by someone else. Females were more likely than males to report recent sexual intercourse and to have IDU sex partners. Females and males were not different with respect to education, race/ethnicity, or housing status. In logistic regression models for borrowing a used needle and sharing drug preparation equipment, increased risk in females was explained by having an injection partner who was also a sexual partner. Injecting risk was greater in the young female compared to male IDUs despite equivalent frequency of injecting. Overlapping sexual and injection partnerships were a key factor in explaining increased injection risk in females. Females were more likely to be injected by another IDU even after adjusting for years injecting, being in a relationship with another IDU, and other potential confounders. Interventions to reduce sexual and injection practices that put women at risk of contracting hepatitis and HIV are needed.

  18. Equipment abnormality monitoring device

    International Nuclear Information System (INIS)

    Ando, Yasumasa

    1991-01-01

    When an operator hears sounds in a plantsite, the operator compares normal sounds of equipment which he previously heard and remembered with sounds he actually hears, to judge if they are normal or abnormal. According to the method, there is a worry that abnormal conditions can not be appropriately judged in a case where the number of objective equipments is increased and in a case that the sounds are changed gradually slightly. Then, the device of the present invention comprises a plurality of monitors for monitoring the operation sound of equipments, a recording/reproducing device for recording and reproducing the signals, a selection device for selecting the reproducing signals among the recorded signals, an acoustic device for converting the signals to sounds, a switching device for switching the signals to be transmitted to the acoustic device between to signals of the monitor and the recording/reproducing signals. The abnormality of the equipments can be determined easily by comparing the sounds representing the operation conditions of equipments for controlling the plant operation and the sounds recorded in their normal conditions. (N.H.)

  19. Prioritizing equipment for replacement.

    Science.gov (United States)

    Capuano, Mike

    2010-01-01

    It is suggested that clinical engineers take the lead in formulating evaluation processes to recommend equipment replacement. Their skill, knowledge, and experience, combined with access to equipment databases, make them a logical choice. Based on ideas from Fennigkoh's scheme, elements such as age, vendor support, accumulated maintenance cost, and function/risk were used.6 Other more subjective criteria such as cost benefits and efficacy of newer technology were not used. The element of downtime was also omitted due to the data element not being available. The resulting Periop Master Equipment List and its rationale was presented to the Perioperative Services Program Council. They deemed the criteria to be robust and provided overwhelming acceptance of the list. It was quickly put to use to estimate required capital funding, justify items already thought to need replacement, and identify high-priority ranked items for replacement. Incorporating prioritization criteria into an existing equipment database would be ideal. Some commercially available systems do have the basic elements of this. Maintaining replacement data can be labor-intensive regardless of the method used. There is usually little time to perform the tasks necessary for prioritizing equipment. However, where appropriate, a clinical engineering department might be able to conduct such an exercise as shown in the following case study.

  20. Radioactive decontamination of equipment

    International Nuclear Information System (INIS)

    1982-03-01

    After a recall of some definitions relating to decontamination techniques and of the regulation into effect, the principles to be respected to arrange rationally work zones are quoted while insisting more particularly on the types of coatings which facilitate maintenance operations and the dismantling of these installations. Then, the processes and equipments to use in decontamination units for routine or particular operations are described; the list of recommended chemical products to decontaminate the equipment is given. The influence of these treatments on the state and the duration of life of equipments is studied, and some perfectible methods are quoted. In the appendix, are given: the limits of surface contamination accepted in the centers; a standard project which defines the criteria of admissible residual contamination in wastes considered as cold wastes; some remarks on the interest that certain special ventilation and air curtain devices for the protection of operators working on apparatus generating contaminated dusts [fr

  1. Equipment Operational Requirements

    Energy Technology Data Exchange (ETDEWEB)

    Greenwalt, B; Henderer, B; Hibbard, W; Mercer, M

    2009-06-11

    The Iraq Department of Border Enforcement is rich in personnel, but poor in equipment. An effective border control system must include detection, discrimination, decision, tracking and interdiction, capture, identification, and disposition. An equipment solution that addresses only a part of this will not succeed, likewise equipment by itself is not the answer without considering the personnel and how they would employ the equipment. The solution should take advantage of the existing in-place system and address all of the critical functions. The solutions are envisioned as being implemented in a phased manner, where Solution 1 is followed by Solution 2 and eventually by Solution 3. This allows adequate time for training and gaining operational experience for successively more complex equipment. Detailed descriptions of the components follow the solution descriptions. Solution 1 - This solution is based on changes to CONOPs, and does not have a technology component. It consists of observers at the forts and annexes, forward patrols along the swamp edge, in depth patrols approximately 10 kilometers inland from the swamp, and checkpoints on major roads. Solution 2 - This solution adds a ground sensor array to the Solution 1 system. Solution 3 - This solution is based around installing a radar/video camera system on each fort. It employs the CONOPS from Solution 1, but uses minimal ground sensors deployed only in areas with poor radar/video camera coverage (such as canals and streams shielded by vegetation), or by roads covered by radar but outside the range of the radar associated cameras. This document provides broad operational requirements for major equipment components along with sufficient operational details to allow the technical community to identify potential hardware candidates. Continuing analysis will develop quantities required and more detailed tactics, techniques, and procedures.

  2. Charging equipment. Ladegeraet

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, E

    1981-09-17

    The invention refers to a charging equipment, particularly on board charging equipment for charging traction batteries of an electric vehicle from the AC mains supply, consisting of a DC converter, which contains a controlled power transistor, a switching off unloading circuit and a power transmitter, where the secondary winding is connected in series with a rectifier diode, and a smoothing capacitor is connected in parallel with this series circuit. A converter module is provided, which consists of two DC voltage converters, whose power transistors are controlled by a control circuit in opposition with a phase displacement of 180/sup 0/.

  3. Lessons Learned from Missing Flooding Barriers Operating Experience

    International Nuclear Information System (INIS)

    Simic, Z.; Veira, M. P.

    2016-01-01

    Flooding hazard is highly significant for nuclear power plant safety because of its potential for common cause impact on safety related systems, and because operating experience reviews regularly identify flooding as a cause of concern. Source of the flooding could be external (location) or internal (plant design). The amount of flooding water could vary but even small amount might suffice to affect redundant trains of safety related systems for power supply and cooling. The protection from the flooding is related to the design-basis flood level (DBFL) and it consists of three elements: structural, organizational and accessibility. Determination of the DBFL is critical, as Fukushima Daiichi accident terribly proved. However, as the topic of flooding is very broad, the scope of this paper is focused only on the issues related to the missing flood barriers. Structural measures are physically preventing flooding water to reach or damage safety related system, and they could be permanent or temporary. For temporary measures it is important to have necessary material, equipment and organizational capacity for the timely implementation. Maintenance is important for permanent protection and periodical review is important for assuring readiness and feasibility of temporary flooding protection. Final flooding protection element is assured accessibility to safety related systems during the flooding. Appropriate flooding protection is based on the right implementation of design requirements, proper maintenance and periodic reviews. Operating experience is constantly proving how numerous water sources and systems interactions make flooding protection challenging. This paper is presenting recent related operating experience feedback involving equipment, procedures and analysis. Most frequent deficiencies are: inadequate, degraded or missing seals that would allow floodwaters into safety related spaces. Procedures are inadequate typically because they underestimate necessary

  4. MISSE PEACE Polymers Atomic Oxygen Erosion Results

    Science.gov (United States)

    deGroh, Kim, K.; Banks, Bruce A.; McCarthy, Catherine E.; Rucker, Rochelle N.; Roberts, Lily M.; Berger, Lauren A.

    2006-01-01

    Forty-one different polymer samples, collectively called the Polymer Erosion and Contamination Experiment (PEACE) Polymers, have been exposed to the low Earth orbit (LEO) environment on the exterior of the International Space Station (ISS) for nearly 4 years as part of Materials International Space Station Experiment 2 (MISSE 2). The objective of the PEACE Polymers experiment was to determine the atomic oxygen erosion yield of a wide variety of polymeric materials after long term exposure to the space environment. The polymers range from those commonly used for spacecraft applications, such as Teflon (DuPont) FEP, to more recently developed polymers, such as high temperature polyimide PMR (polymerization of monomer reactants). Additional polymers were included to explore erosion yield dependence upon chemical composition. The MISSE PEACE Polymers experiment was flown in MISSE Passive Experiment Carrier 2 (PEC 2), tray 1, on the exterior of the ISS Quest Airlock and was exposed to atomic oxygen along with solar and charged particle radiation. MISSE 2 was successfully retrieved during a space walk on July 30, 2005, during Discovery s STS-114 Return to Flight mission. Details on the specific polymers flown, flight sample fabrication, pre-flight and post-flight characterization techniques, and atomic oxygen fluence calculations are discussed along with a summary of the atomic oxygen erosion yield results. The MISSE 2 PEACE Polymers experiment is unique because it has the widest variety of polymers flown in LEO for a long duration and provides extremely valuable erosion yield data for spacecraft design purposes.

  5. Breast carcinomas: why are they missed?

    Science.gov (United States)

    Muttarak, M; Pojchamarnwiputh, S; Chaiwun, B

    2006-10-01

    Mammography has proven to be an effective modality for the detection of early breast carcinoma. However, 4-34 percent of breast cancers may be missed at mammography. Delayed diagnosis of breast carcinoma results in an unfavourable prognosis. The objective of this study was to determine the causes and characteristics of breast carcinomas missed by mammography at our institution, with the aim of reducing the rate of missed carcinoma. We reviewed the reports of 13,191 mammograms performed over a five-year period. Breast Imaging Reporting and Data Systems (BI-RADS) were used for the mammographical assessment, and reports were cross-referenced with the histological diagnosis of breast carcinoma. Causes of missed carcinomas were classified. Of 344 patients who had breast carcinoma and had mammograms done prior to surgery, 18 (5.2 percent) failed to be diagnosed by mammography. Of these, five were caused by dense breast parenchyma obscuring the lesions, 11 were due to perception and interpretation errors, and one each from unusual lesion characteristics and poor positioning. Several factors, including dense breast parenchyma obscuring a lesion, perception error, interpretation error, unusual lesion characteristics, and poor technique or positioning, are possible causes of missed breast cancers.

  6. Substituting missing data in compositional analysis

    Energy Technology Data Exchange (ETDEWEB)

    Real, Carlos, E-mail: carlos.real@usc.es [Area de Ecologia, Departamento de Biologia Celular y Ecologia, Escuela Politecnica Superior, Universidad de Santiago de Compostela, 27002 Lugo (Spain); Angel Fernandez, J.; Aboal, Jesus R.; Carballeira, Alejo [Area de Ecologia, Departamento de Biologia Celular y Ecologia, Facultad de Biologia, Universidad de Santiago de Compostela, 15782 Santiago de Compostela (Spain)

    2011-10-15

    Multivariate analysis of environmental data sets requires the absence of missing values or their substitution by small values. However, if the data is transformed logarithmically prior to the analysis, this solution cannot be applied because the logarithm of a small value might become an outlier. Several methods for substituting the missing values can be found in the literature although none of them guarantees that no distortion of the structure of the data set is produced. We propose a method for the assessment of these distortions which can be used for deciding whether to retain or not the samples or variables containing missing values and for the investigation of the performance of different substitution techniques. The method analyzes the structure of the distances among samples using Mantel tests. We present an application of the method to PCDD/F data measured in samples of terrestrial moss as part of a biomonitoring study. - Highlights: > Missing values in multivariate data sets must be substituted prior to analysis. > The substituted values can modify the structure of the data set. > We developed a method to estimate the magnitude of the alterations. > The method is simple and based on the Mantel test. > The method allowed the identification of problematic variables in a sample data set. - A method is presented for the assessment of the possible distortions in multivariate analysis caused by the substitution of missing values.

  7. Substituting missing data in compositional analysis

    International Nuclear Information System (INIS)

    Real, Carlos; Angel Fernandez, J.; Aboal, Jesus R.; Carballeira, Alejo

    2011-01-01

    Multivariate analysis of environmental data sets requires the absence of missing values or their substitution by small values. However, if the data is transformed logarithmically prior to the analysis, this solution cannot be applied because the logarithm of a small value might become an outlier. Several methods for substituting the missing values can be found in the literature although none of them guarantees that no distortion of the structure of the data set is produced. We propose a method for the assessment of these distortions which can be used for deciding whether to retain or not the samples or variables containing missing values and for the investigation of the performance of different substitution techniques. The method analyzes the structure of the distances among samples using Mantel tests. We present an application of the method to PCDD/F data measured in samples of terrestrial moss as part of a biomonitoring study. - Highlights: → Missing values in multivariate data sets must be substituted prior to analysis. → The substituted values can modify the structure of the data set. → We developed a method to estimate the magnitude of the alterations. → The method is simple and based on the Mantel test. → The method allowed the identification of problematic variables in a sample data set. - A method is presented for the assessment of the possible distortions in multivariate analysis caused by the substitution of missing values.

  8. Direct injection of high pressure gas : scaling properties of pulsed turbulent jets

    NARCIS (Netherlands)

    Baert, R.S.G.; Klaassen, A.; Doosje, E.

    2010-01-01

    Existing gasoline DI injection equipment has been modified to generate single hole pulsed gas jets. Injection experiments have been performed at combinations of 3 different pressure ratios (2 of which supercritical) respectively 3 different hole geometries (i.e. length to diameter ratios). Injection

  9. Long-term follow-up of high-pressure injection injuries to the hand

    NARCIS (Netherlands)

    Wieder, Anat; Lapid, Oren; Plakht, Ygal; Sagi, Amiram

    2006-01-01

    High-pressure injection injury is an injury caused by accidental injection of substances by industrial equipment. This injury may have devastating sequelae. The goal of this study was to assess the long-term outcome of high-pressure injection injury to the hand. In this historical prospective study,

  10. Analysis of Dynamic Characteristics of Water Injection Pump

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Myeong; Lee, Jeong Hoon; Ha, Jeong Min; Ahn, Byung Hyun; Kim, Won Cheol; Choi, Byeong Keun [Gyeongsang Nat' l Univ., Jinju (Korea, Republic of)

    2013-12-15

    Water injection pump outputs oil with high pressure during this process, seawater is injected into the well to recover the well pressure and maintain high productivity. A water injection pump has high productivity, and herefore, it serves as a key piece of equipment in marine plants. In this light, water injection pumps are being studied widely in industry. In this study, the rotor dynamics is analyzed to determine the natural frequency according to the bearing stiffness and operation speed change. This study aims to establish the pump reliability through critical speed, stability, and unbalance response analysis.

  11. Experimental equipment, ch. 6

    International Nuclear Information System (INIS)

    Boomstra, F.; Hoogenboom, A.M.; Prins, C.M.; Strasters, B.A.; Vermeer, A.; Wit, P. de; Zwol, N.A. van.

    1977-01-01

    The experimental equipment in use at Utrecht university is discussed. Attention is paid to the tandem Van de Graaff accelerator and the 4MV and 1MV accelerators. The detection systems for gamma-ray spectroscopy are reviewed with emphasis on the compton-suppression spectrometer. The data-handling system used for experiments with the tandem is also briefly discussed

  12. Equipment gift to Monaco

    International Nuclear Information System (INIS)

    1970-01-01

    Research work at the Agency's Laboratory of Marine Radioactivity in Monaco, including that concerned with pollution of the sea, has been made more effective by its latest acquisition of equipment. This is a spectrophotometer donated by the Federal Republic of Germany. (author)

  13. Lifetime of Mechanical Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Leland, K.

    1999-07-01

    The gas plant at Kaarstoe was built as part of the Statpipe gas transport system and went on stream in 1985. In 1993 another line was routed from the Sleipner field to carry condensate, and the plant was extended accordingly. Today heavy additional supply- and export lines are under construction, and the plant is extended more than ever. The main role of the factory is to separate the raw gas into commercial products and to pump or ship it to the markets. The site covers a large number of well-known mechanical equipment. This presentation deals with piping, mechanical and structural disciplines. The lifetime of mechanical equipment is often difficult to predict as it depends on many factors, and the subject is complex. Mechanical equipment has been kept in-house, which provides detailed knowledge of the stages from a new to a 14 years old plant. The production regularity has always been very high, as required. The standard of the equipment is well kept, support systems are efficient, and human improvisation is extremely valuable.

  14. Safeguards techniques and equipment

    International Nuclear Information System (INIS)

    1997-01-01

    The current booklet is intended to give a full and balanced description of the techniques and equipment used for both nuclear material accountancy and containment and surveillance measures, and for the new safeguards measure of environmental sampling. As new verification measures continue to be developed, the material in the booklet will be periodically reviewed and updated versions issued. (author)

  15. Equipping tomorrow's fire manager

    Science.gov (United States)

    Christopher A. Dicus

    2008-01-01

    Fire managers are challenged with an ever-increasing array of both responsibilities and critics. As in the past, fire managers must master the elements of fire behavior and ecology using the latest technologies. In addition, today’s managers must be equipped with the skills necessary to understand and liaise with a burgeoning group of vocal stakeholders while also...

  16. Electrical equipment design library

    International Nuclear Information System (INIS)

    1994-01-01

    This book guides the design supervision, construction order for electrical equipment. The contents of this library are let's use electricity like this, leading-in-pole and casual power, electric pole install below 300KVA, electric pole install below 301∼1000KVA, electric pole install exceed 1000KVA, rooftop install exceed 1000KVA, CUBICLE type, 154KV services. It adds an appendix.

  17. Orphee reactor experimental equipment

    International Nuclear Information System (INIS)

    1987-01-01

    Experimental equipment around the ORPHEE reactor is presented. The neutron source; and the spectrometers and sample environment (inelastic and quasi-elastic scattering, elastic scattering, spread scattering, small angle scattering) are described. An experiment proposal and reports guide is supplied [fr

  18. Seismic qualification of equipment

    International Nuclear Information System (INIS)

    Heidebrecht, A.C.; Tso, W.K.

    1983-03-01

    This report describes the results of an investigation into the seismic qualification of equipment located in CANDU nuclear power plants. It is particularly concerned with the evaluation of current seismic qualification requirements, the development of a suitable methodology for the seismic qualification of safety systems, and the evaluation of seismic qualification analysis and testing procedures

  19. Underground coal equipment

    Energy Technology Data Exchange (ETDEWEB)

    Chadwick, J.

    2002-12-01

    This paper reports on increasing automation and enhanced productivity on longwalls, new development cutting and bolting technologies and haulage systems. Amongst equipment discussed is DBT's Electra series EL3000 shearer, the Dosco LH1400 roadheader with onboard bolters, and Joy 12 CM30 continuous miners. 4 photos.

  20. Missing data imputation: focusing on single imputation.

    Science.gov (United States)

    Zhang, Zhongheng

    2016-01-01

    Complete case analysis is widely used for handling missing data, and it is the default method in many statistical packages. However, this method may introduce bias and some useful information will be omitted from analysis. Therefore, many imputation methods are developed to make gap end. The present article focuses on single imputation. Imputations with mean, median and mode are simple but, like complete case analysis, can introduce bias on mean and deviation. Furthermore, they ignore relationship with other variables. Regression imputation can preserve relationship between missing values and other variables. There are many sophisticated methods exist to handle missing values in longitudinal data. This article focuses primarily on how to implement R code to perform single imputation, while avoiding complex mathematical calculations.

  1. Time Series Forecasting with Missing Values

    Directory of Open Access Journals (Sweden)

    Shin-Fu Wu

    2015-11-01

    Full Text Available Time series prediction has become more popular in various kinds of applications such as weather prediction, control engineering, financial analysis, industrial monitoring, etc. To deal with real-world problems, we are often faced with missing values in the data due to sensor malfunctions or human errors. Traditionally, the missing values are simply omitted or replaced by means of imputation methods. However, omitting those missing values may cause temporal discontinuity. Imputation methods, on the other hand, may alter the original time series. In this study, we propose a novel forecasting method based on least squares support vector machine (LSSVM. We employ the input patterns with the temporal information which is defined as local time index (LTI. Time series data as well as local time indexes are fed to LSSVM for doing forecasting without imputation. We compare the forecasting performance of our method with other imputation methods. Experimental results show that the proposed method is promising and is worth further investigations.

  2. Collateral missing value imputation: a new robust missing value estimation algorithm for microarray data.

    Science.gov (United States)

    Sehgal, Muhammad Shoaib B; Gondal, Iqbal; Dooley, Laurence S

    2005-05-15

    Microarray data are used in a range of application areas in biology, although often it contains considerable numbers of missing values. These missing values can significantly affect subsequent statistical analysis and machine learning algorithms so there is a strong motivation to estimate these values as accurately as possible before using these algorithms. While many imputation algorithms have been proposed, more robust techniques need to be developed so that further analysis of biological data can be accurately undertaken. In this paper, an innovative missing value imputation algorithm called collateral missing value estimation (CMVE) is presented which uses multiple covariance-based imputation matrices for the final prediction of missing values. The matrices are computed and optimized using least square regression and linear programming methods. The new CMVE algorithm has been compared with existing estimation techniques including Bayesian principal component analysis imputation (BPCA), least square impute (LSImpute) and K-nearest neighbour (KNN). All these methods were rigorously tested to estimate missing values in three separate non-time series (ovarian cancer based) and one time series (yeast sporulation) dataset. Each method was quantitatively analyzed using the normalized root mean square (NRMS) error measure, covering a wide range of randomly introduced missing value probabilities from 0.01 to 0.2. Experiments were also undertaken on the yeast dataset, which comprised 1.7% actual missing values, to test the hypothesis that CMVE performed better not only for randomly occurring but also for a real distribution of missing values. The results confirmed that CMVE consistently demonstrated superior and robust estimation capability of missing values compared with other methods for both series types of data, for the same order of computational complexity. A concise theoretical framework has also been formulated to validate the improved performance of the CMVE

  3. Characteristics of pressure wave in common rail fuel injection system of high-speed direct injection diesel engines

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Herfatmanesh

    2016-05-01

    Full Text Available The latest generation of high-pressure common rail equipment now provides diesel engines possibility to apply as many as eight separate injection pulses within the engine cycle for reducing emissions and for smoothing combustion. With these complicated injection arrangements, optimizations of operating parameters for various driving conditions are considerably difficult, particularly when integrating fuel injection parameters with other operating parameters such as exhaust gas recirculation rate and boost pressure together for evaluating calibration results. Understanding the detailed effects of fuel injection parameters upon combustion characteristics and emission formation is therefore particularly critical. In this article, the results and discussion of experimental investigations on a high-speed direct injection light-duty diesel engine test bed are presented for evaluating and analyzing the effects of main adjustable parameters of the fuel injection system on all regulated emission gases and torque performance. Main injection timing, rail pressure, pilot amount, and particularly pilot timing have been examined. The results show that optimization of each of those adjustable parameters is beneficial for emission reduction and torque improvement under different operating conditions. By exploring the variation in the interval between the pilot injection and the main injection, it is found that the pressure wave in the common rail has a significant influence on the subsequent injection. This suggests that special attentions must be paid for adjusting pilot timing or any injection interval when multi-injection is used. With analyzing the fuel amount oscillation of the subsequent injections to pilot separation, it demonstrates that the frequency of regular oscillations of the actual fuel amount or the injection pulse width with the variation in pilot separation is always the same for a specified fuel injection system, regardless of engine speed

  4. HIV and Injection Drug Use PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2016-11-29

    This 60 second public service announcement is based on the December 2016 CDC Vital Signs report. Sharing needles, syringes, and other injection equipment puts you at risk for getting HIV and other infections, including hepatitis. Learn how to reduce your HIV risk.  Created: 11/29/2016 by National Center for HIV/AIDS, Viral Hepatitis, Sexual Transmitted Diseases and Tuberculosis Prevention (NCHHSTP).   Date Released: 11/29/2016.

  5. Digital Twin concept for smart injection molding

    Science.gov (United States)

    Liau, Y.; Lee, H.; Ryu, K.

    2018-03-01

    Injection molding industry has evolved over decades and became the most common method to manufacture plastic parts. Monitoring and improvement in the injection molding industry are usually performed separately in each stage, i.e. mold design, mold making and injection molding process. However, in order to make a breakthrough and survive in the industrial revolution, all the stages in injection molding need to be linked and communicated with each other. Any changes in one stage will cause a certain effect in other stage because there is a correlation between each other. Hence, the simulation should not only based on the input of historical data, but it also needs to include the current condition of equipment and prediction of future events in other stages to make the responsive decision. This can be achieved by implementing the concept of Digital Twin that models the entire process as a virtual model and enables bidirectional control with the physical process. This paper presented types of data and technology required to build the Digital Twin for the injection molding industry. The concept includes Digital Twin of each stage and integration of these Digital Twin model as a thoroughgoing model of the injection molding industry.

  6. Visual communication and terminal equipment

    International Nuclear Information System (INIS)

    Kang, Cheol Hui

    1988-06-01

    This book is divided two parts about visual communication and terminal equipment. The first part introduces visual communication, which deals with foundation of visual communication, technique of visual communication, equipment of visual communication, a facsimile and pictorial image system. The second part contains terminal equipment such as telephone, terminal equipment for data transmission on constitution and constituent of terminal equipment for data transmission, input device and output device, terminal device and up-to-date terminal device.

  7. Visual communication and terminal equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Cheol Hui

    1988-06-15

    This book is divided two parts about visual communication and terminal equipment. The first part introduces visual communication, which deals with foundation of visual communication, technique of visual communication, equipment of visual communication, a facsimile and pictorial image system. The second part contains terminal equipment such as telephone, terminal equipment for data transmission on constitution and constituent of terminal equipment for data transmission, input device and output device, terminal device and up-to-date terminal device.

  8. SQL injection detection system

    OpenAIRE

    Vargonas, Vytautas

    2017-01-01

    SQL injection detection system Programmers do not always ensure security of developed systems. That is why it is important to look for solutions outside being reliant on developers. In this work SQL injection detection system is proposed. The system analyzes HTTP request parameters and detects intrusions. It is based on unsupervised machine learning. Trained by regular request data system detects outlier user parameters. Since training is not reliant on previous knowledge of SQL injections, t...

  9. Equipment cost optimization

    International Nuclear Information System (INIS)

    Ribeiro, E.M.; Farias, M.A.; Dreyer, S.R.B.

    1995-01-01

    Considering the importance of the cost of material and equipment in the overall cost profile of an oil company, which in the case of Petrobras, represents approximately 23% of the total operational cost or 10% of the sales, an organization for the optimization of such costs has been established within Petrobras. Programs are developed aiming at: optimization of life-cycle cost of material and equipment; optimization of industrial processes costs through material development. This paper describes the methodology used in the management of the development programs and presents some examples of concluded and ongoing programs, which are conducted in permanent cooperation with suppliers, technical laboratories and research institutions and have been showing relevant results

  10. X-ray equipment

    International Nuclear Information System (INIS)

    Redmayne, I.G.B.

    1988-01-01

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.)

  11. X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Redmayne, I.G.B.

    1988-01-06

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.).

  12. Tube for irradiation equipment

    International Nuclear Information System (INIS)

    Goehrich, K.; Vogt, H.

    1979-01-01

    This patent describes a tube for irradiation equipment for limiting an emergent beam, with a baseplate, possessing a central aperture, intended for attaching to the equipment, as well as four carrier plates, each of which possesses a limiting edge and a sliding edge located at right angles thereto. The carrier plates are located parallel to the baseplate, the limiting edge of each carrier plate resting against the sliding edge of the adjacent carrier plate and each of the two mutually opposite pairs of carrier plates being displaceable, parallel to the direction of its sliding edges and symmetrically to the center of the transmission aperture, for the purpose of continuously varying the transmission aperture defined by the limiting edges, during which displacement each of the displaced carrier plates carries with it the carrier plate, resting against the limiting edge of the former plate, parallel to the direction of the limiting edge of the latter plate. 8 claims

  13. Equipment for isotope diagnostics

    International Nuclear Information System (INIS)

    Platz, W.

    1976-01-01

    The invention concerns an improvement of equipment for isotope diagnostics allowing to mark special intensity ranges of the recorded measurements by means of different colors. For undisturbed operation it is of advantage to avoid electric circuits between movable and unmovable parts of the color recorder. According to the invention, long gear wheels of glass fiber-reinforced polyamide are used for these connections. (ORU) [de

  14. Soviet equipment flies in

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    End of February 1977 a Soviet Ilyushin-76 heavy freight aircraft landed at Cointrin airport having on board fifty large wire proprtional chambers and associated apparatus, together weighing 10 tons, supplied by the Joint Institute for Nuclear Research, Dubna, USSR. The equipment was for the CERN- Dubna-Munich-Saclay experiment NA4 on deep inelastic muon scattering being set up in the North Area of SPS. See Weekly Bulletin 11/78.

  15. Labelling of equipment dispensers.

    Science.gov (United States)

    Gray, D C

    1993-01-01

    A new labelling system for use on medical equipment dispensers is tested. This system uses one of the objects stored in each unit of the dispenser as the 'label', by attaching it to the front of the dispenser with tape. The new system was compared to conventional written labelling by timing subjects asked to select items from two dispensers. The new system was 27% quicker than the conventional system. Images Fig. 1 PMID:8110335

  16. Piezoelectric Injection Systems

    Science.gov (United States)

    Mock, R.; Lubitz, K.

    The origin of direct injection can be doubtlessly attributed to Rudolf Diesel who used air assisted injection for fuel atomisation in his first self-ignition engine. Although it became apparent already at that time that direct injection leads to reduced specific fuel consumption compared to other methods of fuel injection, it was not used in passenger cars for the moment because of its disadvantageous noise generation as the requirements with regard to comfort were seen as more important than a reduced specific consumption.

  17. Urinary incontinence - injectable implant

    Science.gov (United States)

    ... repair; ISD repair; Injectable bulking agents for stress urinary incontinence ... and disorders: physiology of micturition, voiding dysfunction, urinary incontinence, urinary tract infections, and painful bladder syndrome. In: Lobo ...

  18. Equipment Obsolescence Management Program

    Energy Technology Data Exchange (ETDEWEB)

    Redmond, J.

    2014-07-01

    Nuclear Power Plant (NPP) Operators are challenged with securing reliable supply channels for safety related equipment due to equipment obsolescence. Many Original Equipment Manufacturers (OEMs) have terminated production of spare parts and product life-cycle support. The average component life cycles are much shorter than the NPP design life, which means that replacement components and parts for the original NPP systems are not available for the complete design life of the NPPs. The lack or scarcity of replacement parts adversely affects plant reliability and ultimately the profitability of the affected NPPs. This problem is further compounded when NPPs pursue license renewal and approval for plant-life extension. A reliable and predictable supply of replacement co components is necessary for NPPs to remain economically competitive and meet regulatory requirements and guidelines. Electrical and I and C components, in particular, have short product life cycles and obsolescence issues must be managed pro actively and not reactively in order to mitigate the risk to the NPP to ensure reliable and economic NPP operation. (Author)

  19. Personal protective equipment

    International Nuclear Information System (INIS)

    2004-01-01

    This Practical Radiation Technical Manual is one of a series that has been designed to provide guidance on radiological protection for employers, radiation protection officers, managers and other technically competent persons who have responsibility for ensuring the safety of employees working with ionizing radiation. The Manual may be used with the appropriate IAEA Practical Radiation Safety Manuals to provide training, instruction and information for all employees engaged in work with ionizing radiation. Personal protective equipment (PPE) includes clothing or other special equipment that is issued to individual workers to provide protection against actual or potential exposure to ionizing radiations. It is used to protect each worker against the prevailing risk of external or internal exposure in circumstances in which it is not reasonably practicable to provide complete protection by means of engineering controls or administrative methods. Adequate personal protection depends on PPE being correctly selected, fitted and maintained. Appropriate training for the users and arrangements to monitor usage are also necessary to ensure that PPE provides the intended degree of protection effectively. This Manual explains the principal types of PPE, including protective clothing and respiratory protective equipment (RPE). Examples of working procedures are also described to indicate how PPE should be used within a safe system of work. The Manual will be of most benefit if it forms part of a more comprehensive training programme or is supplemented by the advice of a qualified expert in radiation protection. Some of the RPE described in this Manual should be used under the guidance of a qualified expert

  20. Missing Strands? Dealing with Hair Loss

    Science.gov (United States)

    ... 2017 Print this issue Missing Strands? Dealing with Hair Loss En español Send us your comments Hair loss is often associated with men and aging, but ... or their treatments, and many other things cause hair loss. The most common type of hair loss is ...

  1. On testing the missing at random assumption

    DEFF Research Database (Denmark)

    Jaeger, Manfred

    2006-01-01

    Most approaches to learning from incomplete data are based on the assumption that unobserved values are missing at random (mar). While the mar assumption, as such, is not testable, it can become testable in the context of other distributional assumptions, e.g. the naive Bayes assumption...

  2. Missing mass from low-luminosity stars

    International Nuclear Information System (INIS)

    Hawkins, M.R.S.

    1986-01-01

    Results from a deep photometric survey for low-luminosity stars show a turnup to the luminosity function at faint magnitudes, and reopen the possibility that the missing mass in the solar neighbourhood is made up of stars after all. (author)

  3. Dealing with gene expression missing data.

    Science.gov (United States)

    Brás, L P; Menezes, J C

    2006-05-01

    Compared evaluation of different methods is presented for estimating missing values in microarray data: weighted K-nearest neighbours imputation (KNNimpute), regression-based methods such as local least squares imputation (LLSimpute) and partial least squares imputation (PLSimpute) and Bayesian principal component analysis (BPCA). The influence in prediction accuracy of some factors, such as methods' parameters, type of data relationships used in the estimation process (i.e. row-wise, column-wise or both), missing rate and pattern and type of experiment [time series (TS), non-time series (NTS) or mixed (MIX) experiments] is elucidated. Improvements based on the iterative use of data (iterative LLS and PLS imputation--ILLSimpute and IPLSimpute), the need to perform initial imputations (modified PLS and Helland PLS imputation--MPLSimpute and HPLSimpute) and the type of relationships employed (KNNarray, LLSarray, HPLSarray and alternating PLS--APLSimpute) are proposed. Overall, it is shown that data set properties (type of experiment, missing rate and pattern) affect the data similarity structure, therefore influencing the methods' performance. LLSimpute and ILLSimpute are preferable in the presence of data with a stronger similarity structure (TS and MIX experiments), whereas PLS-based methods (MPLSimpute, IPLSimpute and APLSimpute) are preferable when estimating NTS missing data.

  4. Missed opportunities and inappropriately given vaccines reduce ...

    African Journals Online (AJOL)

    Objectives: To quantify missed opportunities for immunisation, document reasons for their occurrence and evaluate the extent of inappropriately given vaccine doses. Design: A cross sectional study of children under two years of age attending health facilities. Setting: Six health facilities predominantly serving the slums of ...

  5. Determinants Of Missed Opportunities For Immunization Among ...

    African Journals Online (AJOL)

    Factors responsible for the missed opportunities included the attitude of the health worker, prolonged time of waiting to receive vaccine, immunization clashing with other schedules and transportation problem. Respondents' level ofknowledge on immunization and educational background were significantly associated with ...

  6. All hypertopologies are hit-and-miss

    Directory of Open Access Journals (Sweden)

    Somshekhar Naimpally

    2002-04-01

    Full Text Available We solve a long standing problem by showing that all known hypertopologies are hit-and-miss. Our solution is not merely of theoretical importance. This representation is useful in the study of comparison of the Hausdorff-Bourbaki or H-B uniform topologies and the Wijsman topologies among themselves and with others. Up to now some of these comparisons needed intricate manipulations. The H-B uniform topologies were the subject of intense activity in the 1960's in connection with the Isbell-Smith problem. We show that they are proximally locally finite topologies from which the solution to the above problem follows easily. It is known that the Wijsman topology on the hyperspace is the proximal ball (hit-and-miss topology in”nice” metric spaces including the normed linear spaces. With the introduction of a new far-miss topology we show that the Wijsman topology is hit-and-miss for all metric spaces. From this follows a natural generalization of the Wijsman topology to the hyperspace of any T1 space. Several existing results in the literature are easy consequences of our work.

  7. Flash CS4: The Missing Manual

    CERN Document Server

    Grover, Chris

    2008-01-01

    Unlock the power of Flash and bring gorgeous animations to life onscreen. Flash CS4: The Missing Manual includes a complete primer on animation, a guided tour of the program's tools and capabilities, lots of new illustrations, and more details on working with video. Beginners will learn to use the software in no time, and experienced Flash designers will improve their skills.

  8. What's Missing? Anti-Racist Sex Education!

    Science.gov (United States)

    Whitten, Amanda; Sethna, Christabelle

    2014-01-01

    Contemporary sexual health curricula in Canada include information about sexual diversity and queer identities, but what remains missing is any explicit discussion of anti-racist sex education. Although there exists federal and provincial support for multiculturalism and anti-racism in schools, contemporary Canadian sex education omits crucial…

  9. How efficient is estimation with missing data?

    DEFF Research Database (Denmark)

    Karadogan, Seliz; Marchegiani, Letizia; Hansen, Lars Kai

    2011-01-01

    percentages (MDP) using a missing completely at random (MCAR) scheme. We compare three MDTs: pairwise deletion (PW), mean imputation (MI) and a maximum likelihood method that we call complete expectation maximization (CEM). We use a synthetic dataset, the Iris dataset and the Pima Indians Diabetes dataset. We...

  10. Generalized canonical correlation analysis with missing values

    NARCIS (Netherlands)

    M. van de Velden (Michel); Y. Takane

    2009-01-01

    textabstractTwo new methods for dealing with missing values in generalized canonical correlation analysis are introduced. The first approach, which does not require iterations, is a generalization of the Test Equating method available for principal component analysis. In the second approach,

  11. Missed Distal Tracheal Foreign Body in Consecutive ...

    African Journals Online (AJOL)

    2017-05-18

    May 18, 2017 ... Since invention, bronchoscopy has become the gold standard in the diagnosis and extraction of airway FB.[4]. Foreign bodies may be missed at ... Since the discovery by Gustav Killian,[9] extraction of tracheobronchial FB has been accomplished with rigid bronchoscopy which is still considered as the gold.

  12. Missed isolated volar dislocation of the scaphoid

    DEFF Research Database (Denmark)

    Kolby, Lise; Larsen, Søren; Jørring, Stig

    2007-01-01

    A patient presented with volar dislocation of the scaphoid, the diagnosis of which had been missed for two weeks. He was treated with open reduction through a combined volar and dorsal approach with decompression of the median nerve, internal fixation, and a cast for eight weeks. One year postope...... postoperatively the functional result was good. A radiograph showed no sign of avascular necrosis....

  13. Missed opportunities for immunisation at Kasungu

    African Journals Online (AJOL)

    work. Some outreach and static clinics still concen- trate their EPI activities on infants and children and largely ignore the mothers who accompany them. Health workers ... sungu District Hospital (KDH) were surveyed. Six. Health Centres ... Table 2 Missed Dpponunities for Immunisation ofEPI Tat'get Gt'Oups at Kmungu ...

  14. Financial report on the investment and maintenance of the RA reactor and equipment, Annex 5

    International Nuclear Information System (INIS)

    2002-01-01

    For the purpose of maintenance of the RA reactor building and equipment, Serbian Ministry of science, technology and development has approved financial support for the following: purchase and installing 12 new battery cells in the reactor building, for purchase of the missing fire protection equipment, and purchasing the material for protection of the roof of the ventilation center. All the planned tasks were fulfilled [sr

  15. Missed retinal breaks in rhegmatogenous retinal detachment

    Directory of Open Access Journals (Sweden)

    Brijesh Takkar

    2016-12-01

    Full Text Available AIM: To evaluate the causes and associations of missed retinal breaks (MRBs and posterior vitreous detachment (PVD in patients with rhegmatogenous retinal detachment (RRD. METHODS: Case sheets of patients undergoing vitreo retinal surgery for RRD at a tertiary eye care centre were evaluated retrospectively. Out of the 378 records screened, 253 were included for analysis of MRBs and 191 patients were included for analysis of PVD, depending on the inclusion criteria. Features of RRD and retinal breaks noted on examination were compared to the status of MRBs and PVD detected during surgery for possible associations. RESULTS: Overall, 27% patients had MRBs. Retinal holes were commonly missed in patients with lattice degeneration while missed retinal tears were associated with presence of complete PVD. Patients operated for cataract surgery were significantly associated with MRBs (P=0.033 with the odds of missing a retinal break being 1.91 as compared to patients with natural lens. Advanced proliferative vitreo retinopathy (PVR and retinal bullae were the most common reasons for missing a retinal break during examination. PVD was present in 52% of the cases and was wrongly assessed in 16%. Retinal bullae, pseudophakia/aphakia, myopia, and horse shoe retinal tears were strongly associated with presence of PVD. Traumatic RRDs were rarely associated with PVD. CONCLUSION: Pseudophakic patients, and patients with retinal bullae or advanced PVR should be carefully screened for MRBs. Though Weiss ring is a good indicator of PVD, it may still be over diagnosed in some cases. PVD is associated with retinal bullae and pseudophakia, and inversely with traumatic RRD.

  16. INJECTION CARBON STRIPPING FOIL ISSUES IN THE SNS ACCUMULATOR RING

    International Nuclear Information System (INIS)

    BEEBE-WANG, J.; LEE, Y.Y.; RAPARIA, D.; WEI, J.

    2001-01-01

    We are reporting the results of studies on issues related to the injection stripping foil in the Spallation Neutron Source (SNS) accumulator ring. The problems related to foil heating and foil lifetime, such as current density distribution and temperature distribution in the foil, are investigated. The impact of injection errors on the beam losses at the foil is studied. The particle traversal rate and the beam losses due to scattering in the foil are summarized. Finally, SNS end-to-end simulation results of the foil-missing rate, the foil-hitting rate and the maximum foil temperature are presented

  17. Electron injection in microtron

    International Nuclear Information System (INIS)

    Axinescu, S.

    1977-01-01

    A review of the methods of injecting electrons in the microtron is presented. A special attention is paid to efficient injection systems developed by Wernholm and Kapitza. A comparison of advantages and disadvantages of both systems is made in relation to the purpose of the microtron. (author)

  18. Glenohumeral Joint Injections

    Science.gov (United States)

    Gross, Christopher; Dhawan, Aman; Harwood, Daniel; Gochanour, Eric; Romeo, Anthony

    2013-01-01

    Context: Intra-articular injections into the glenohumeral joint are commonly performed by musculoskeletal providers, including orthopaedic surgeons, family medicine physicians, rheumatologists, and physician assistants. Despite their frequent use, there is little guidance for injectable treatments to the glenohumeral joint for conditions such as osteoarthritis, adhesive capsulitis, and rheumatoid arthritis. Evidence Acquisition: We performed a comprehensive review of the available literature on glenohumeral injections to help clarify the current evidence-based practice and identify deficits in our understanding. We searched MEDLINE (1948 to December 2011 [week 1]) and EMBASE (1980 to 2011 [week 49]) using various permutations of intra-articular injections AND (corticosteroid OR hyaluronic acid) and (adhesive capsulitis OR arthritis). Results: We identified 1 and 7 studies that investigated intra-articular corticosteroid injections for the treatment of osteoarthritis and adhesive capsulitis, respectively. Two and 3 studies investigated the use of hyaluronic acid in osteoarthritis and adhesive capsulitis, respectively. One study compared corticosteroids and hyaluronic acid injections in the treatment of osteoarthritis, and another discussed adhesive capsulitis. Conclusion: Based on existing studies and their level of evidence, there is only expert opinion to guide corticosteroid injection for osteoarthritis as well as hyaluronic acid injection for osteoarthritis and adhesive capsulitis. PMID:24427384

  19. Dimethyl Ether Injection Studies

    DEFF Research Database (Denmark)

    Sorenson, Spencer C.; Glensvig, Michael; Abata, Duane L.

    1998-01-01

    A series of preliminary investigations has been performed in order to investigate the behavior of DME in a diesel injection environment. These studies have in-cluded visual observations of the spray penetration and angles for high pressure injection into Nitrogen using conventional jerk pump inje...

  20. Scientific Equipment Division - Overview

    International Nuclear Information System (INIS)

    Halik, J.

    2001-01-01

    Full text: The Scientific Equipment Division consists of the Design Group and the Mechanical Workshop. The activity of the Division includes the following: - designing of devices and equipment for experiments in physics, their mechanical construction and assembly. In particular, there are vacuum chambers and installations for HV and UHV; - maintenance and upgrading of the existing installations and equipment in our Institute; - participation of our engineers and technicians in design works, equipment assembly and maintenance for experiments in foreign laboratories. The Design Group is equipped with PC-computers and AutoCAD graphic software (release 2000 and Mechanical Desktop 4.0) and a AO plotter, what allows us to make drawings and 2- and 3-dimensional mechanical documentation to the world standards. The Mechanical Workshop can offer a wide range of machining and treatment methods with satisfactory tolerances and surface quality. It offers the following possibilities: - turning - cylindrical elements of a length up to 2000 mm and a diameter up to 400 mm, and also disc-type elements of a diameter up to 600 mm and a length not exceeding 300 mm; - milling - elements of length up to 1000 mm and gear wheels of diameter up to 300 mm; - grinding - flat surfaces of dimensions up to 300 mm x 1000 mm and cylindrical elements of a diameter up to 200 mm and a length up to 800 mm; - drilling - holes of a diameter up to 50 mm; - welding - electrical and gas welding, including TIG vacuum-tight welding; - soft and hard soldering; - mechanical works including precision engineering; - plastics treatment - machining and polishing using diamond milling, modelling, lamination of various shapes and materials, including plexiglas, scintillators and light-guides; - painting - paint spraying with possibility of using furnace-fred drier of internal dimensions of 800 mm x 800 mm x 800 mm. Our workshop posses CNC milling machine which can be used for machining of work-pieces up to 500 kg

  1. Coal ash monitoring equipment

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, C G; Wormald, M R

    1978-10-02

    The monitoring equipment is used to determine the remainder from combustion (ash slack) of coal in wagons designed for power stations. Next to the rails, a neutron source (252 Cf, 241 Am/Be) is situated, which irradiates the coal with neutrons at a known dose, which produces the reaction 27 Al (n ..gamma..) Al 28. The aluminium content is a measure of the remainder. The 1.78 MeV energy is measured downstream of the rail with a detector. The neutron source can only act in the working position of a loaded wagon.

  2. Management of Transportation Equipment.

    Science.gov (United States)

    1982-11-01

    Record% % %. "jP -M -. M LIh TRANSPORTATION MAENTKENAI4CE SHOP WORKLOAD CONTROL WORK CENTER SADR A-OR .a’* tLR 4.,R53 8114LM 0 o 251 50 75 100 125 ISO ...PDBP 06 7 4892 TRACTOR, WHEEL, INDUST, 14001-20000 PDBP 06 7 4893 TRACTOR, WHEEL, INDUST, 20001-27000 PDBP 06 7 4894 TRACTOR, WHEEL, INDUST, 27001 PDBP...27K TRACTOR, WHEEL, INDUST, 27001 PDBP & UP P-i LINE ITEM 07 LIGHTING AND POWER GENERATION EQUIPMENT 5110 T FLOODLIGHT ELEC FLOODLIGHT, ELEC, TRUCK

  3. Incomplete Early Childhood Immunization Series and Missing Fourth DTaP Immunizations; Missed Opportunities or Missed Visits?

    Science.gov (United States)

    Robison, Steve G

    2013-01-01

    The successful completion of early childhood immunizations is a proxy for overall quality of early care. Immunization statuses are usually assessed by up-to-date (UTD) rates covering combined series of different immunizations. However, series UTD rates often only bear on which single immunization is missing, rather than the success of all immunizations. In the US, most series UTD rates are limited by missing fourth DTaP-containing immunizations (diphtheria/tetanus/pertussis) due at 15 to 18 months of age. Missing 4th DTaP immunizations are associated either with a lack of visits at 15 to 18 months of age, or to visits without immunizations. Typical immunization data however cannot distinguish between these two reasons. This study compared immunization records from the Oregon ALERT IIS with medical encounter records for two-year olds in the Oregon Health Plan. Among those with 3 valid DTaPs by 9 months of age, 31.6% failed to receive a timely 4th DTaP; of those without a 4th DTaP, 42.1% did not have any provider visits from 15 through 18 months of age, while 57.9% had at least one provider visit. Those with a 4th DTaP averaged 2.45 encounters, while those with encounters but without 4th DTaPs averaged 2.23 encounters.

  4. Process Condition Monitoring of Micro Moulding Using a Two-plunger Micro Injection Moulding Machine

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Guerrier, Patrick

    2010-01-01

    The influence of micro injection moulding (µIM) process parameters (melt and mould temperature, piston injection speed and stoke length) on the injection pressure was investigated using Design of Experiments. Direct piston injection pressure measurements were performed and data collected using...... a micro injection moulding machine equipped with a two-pluger injection unit. Miniaturized dog-bone shaped speciments on polyoxymethylene (POM) were moulded over a wide range of processing cpnditions in order to characterize the process and assess its capability. Experimental results obtained under...

  5. Additional Equipment for Soil Biodegradation

    Science.gov (United States)

    Vondráčková, Terezie; Kraus, Michal; Šál, Jiří

    2017-12-01

    Intensification of industrial production, increasing citizens’ living standards, expanding the consumer assortment mean in the production - consumption cycle a constantly increasing occurrence of waste material, which by its very nature must be considered as a source of useful raw materials in all branches of human activity. In addition to strict legislative requirements, a number of circumstances characterize waste management. It is mainly extensive transport associated with the handling and storage of large volumes of substances with a large assortment of materials (substances of all possible physical and chemical properties) and high demands on reliability and time coordination of follow-up processes. Considerable differences in transport distances, a large number of sources, processors and customers, and not least seasonal fluctuations in waste and strong price pressures cannot be overlooked. This highlights the importance of logistics in waste management. Soils that are contaminated with oil and petroleum products are hazardous industrial waste. Methods of industrial waste disposal are landfilling, biological processes, thermal processes and physical and chemical methods. The paper focuses on the possibilities of degradation of oil pollution, in particular biodegradation by bacteria, which is relatively low-cost among technologies. It is necessary to win the fight with time so that no ground water is contaminated. We have developed two additional devices to help reduce oil accident of smaller ranges. In the case of such an oil accident, it is necessary to carry out the permeability test of contaminated soil in time and, on this basis, to choose the technology appropriate to the accident - either in-sit biodegradation - at the site of the accident, or on-sit - to remove the soil and biodegrade it on the designated deposits. A special injection drill was developed for in-sit biodegradation, tossing and aeration equipment of the extracted soil was developed for

  6. Californium-252 Program Equipment Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Chattin, Fred Rhea [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wilson, Kenton [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ezold, Julie G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-12-01

    To successfully continue the 252Cf production and meet the needs of the customers, a comprehensive evaluation of the Building 7920 processing equipment was requested to identify equipment critical to the operational continuity of the program.

  7. Comparative study of oxihydrogen injection in turbocharged compression ignition engines

    Science.gov (United States)

    Barna, L.; Lelea, D.

    2018-01-01

    This document proposes for analysis, comparative study of the turbocharged, compression-ignition engine, equipped with EGR valve, operation in case the injection in intake manifold thereof a maximum flow rate of 1l/min oxyhydrogen resulted of water electrolysis, at two different injection pressures, namely 100 Pa and 3000 Pa, from the point of view of flue gas opacity. We found a substantial reduction of flue gas opacity in both cases compared to conventional diesel operation, but in different proportions.

  8. Computer control of the ISX-B neutral injection beamlines

    International Nuclear Information System (INIS)

    Hanna, P.C.

    1982-09-01

    A system of controls for the Impurity Study Experiment (ISX-B) neutral injection beamlines at the Oak Ridge National Laboratory is presented. The system uses standard CAMAC equipment interfaced to the actual beamline controls and driven by a PDP-11/34 mini-computer. It is designed to relieve the operator of most of the mundane tasks of beam injection and also to reduce the number of operators needed to monitor multiple beamlines

  9. Persulfate injection into a gasoline source zone.

    Science.gov (United States)

    Sra, Kanwartej S; Thomson, Neil R; Barker, Jim F

    2013-07-01

    One pore volume of unactivated sodium persulfate was delivered into an emplaced gasoline residual source zone at CFB Borden. Concentrations of inorganic species (S2O8(2-), SO4(2-), Na(+), dissolved inorganic carbon (DIC)) and selected gasoline compounds (benzene, toluene, ethylbenzene, xylenes, trimethylbenzenes and naphthalene) were monitored across a transect equipped with 90 multilevel sampling points for >10months post-injection. Mass loading (M˙) of compounds constructed from the transect data was used for assessment purposes. Breakthrough of inorganic species was observed when the injection slug crossed the monitoring transect. An increase in [Formula: see text] indicated persulfate consumption during oxidation of gasoline compounds or degradation due to the interaction with aquifer materials. M˙DIC increased by >100% suggesting some mineralization of gasoline compounds during treatment. Mass loading for all the monitored gasoline compounds reduced by 46 to 86% as the inorganic slug crossed the monitoring transect. The cumulative mass discharge across the monitoring transect was 19 to 58% lower than that expected without persulfate injection. After the inorganic injection slug was flushed from the source zone a partial rebound (40 to 80% of baseline levels) of mass discharge of the monitored gasoline compounds was observed. The ensemble of data collected provides insight into the fate and transport of the injected persulfate solution, and the accompanying treatment of a gasoline the source zone. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Persulfate injection into a gasoline source zone

    Science.gov (United States)

    Sra, Kanwartej S.; Thomson, Neil R.; Barker, Jim F.

    2013-07-01

    One pore volume of unactivated sodium persulfate was delivered into an emplaced gasoline residual source zone at CFB Borden. Concentrations of inorganic species (S2O82 -, SO42 -, Na+, dissolved inorganic carbon (DIC)) and selected gasoline compounds (benzene, toluene, ethylbenzene, xylenes, trimethylbenzenes and naphthalene) were monitored across a transect equipped with 90 multilevel sampling points for > 10 months post-injection. Mass loading (M˙) of compounds constructed from the transect data was used for assessment purposes. Breakthrough of inorganic species was observed when the injection slug crossed the monitoring transect. An increase in M indicated persulfate consumption during oxidation of gasoline compounds or degradation due to the interaction with aquifer materials. M increased by > 100% suggesting some mineralization of gasoline compounds during treatment. Mass loading for all the monitored gasoline compounds reduced by 46 to 86% as the inorganic slug crossed the monitoring transect. The cumulative mass discharge across the monitoring transect was 19 to 58% lower than that expected without persulfate injection. After the inorganic injection slug was flushed from the source zone a partial rebound (40 to 80% of baseline levels) of mass discharge of the monitored gasoline compounds was observed. The ensemble of data collected provides insight into the fate and transport of the injected persulfate solution, and the accompanying treatment of a gasoline the source zone.

  11. Congenitally missing mandibular second premolars: clinical options.

    Science.gov (United States)

    Kokich, Vincent G; Kokich, Vincent O

    2006-10-01

    Congenital absence of mandibular second premolars affects many orthodontic patients. The orthodontist must make the proper decision at the appropriate time regarding management of the edentulous space. These spaces can be closed or left open. If the space will be left open for an eventual restoration, the keys during orthodontic treatment are to create the correct amount of space and to leave the alveolar ridge in an ideal condition for a future restoration. If the space will be closed, the clinician must avoid any detrimental alterations to the occlusion and the facial profile. Some early decisions that the orthodontist makes for a patient whose mandibular second premolars are congenitally missing will affect his or her dental health for a lifetime. Therefore, the correct decision must be made at the appropriate time. In this article, we present and discuss various treatment alternatives for managing orthodontic patients with at least 1 congenitally missing mandibular second premolar.

  12. The case of the missing third.

    Science.gov (United States)

    Robertson, Robin

    2005-01-01

    How is it that form arises out of chaos? In attempting to deal with this primary question, time and again a "Missing Third" is posited that lies between extremes. The problem of the "Missing Third" can be traced through nearly the entire history of thought. The form it takes, the problems that arise from it, the solutions suggested for resolving it, are each representative of an age. This paper traces the issue from Plato and Parmenides in the 4th--5th centuries, B.C.; to Neoplatonism in the 3rd--5th centuries; to Locke and Descartes in the 17th century; on to Berkeley and Kant in the 18th century; Fechner and Wundt in the 19th century; to behaviorism and Gestalt psychology, Jung, early in the 20th century, ethology and cybernetics later in the 20th century, then culminates late in the 20th century, with chaos theory.

  13. iLife '05 The Missing Manual

    CERN Document Server

    Pogue, David

    2005-01-01

    The incomparable iLife '05 is the must-have multimedia suite for everyone who owns a Mac--and the envy of everyone who doesn't. iLife '05: The Missing Manual is the definitive iLife '05 book--and what should have come with the suite. There's no better guide to your iLife experience than the #1 bestselling Macintosh author and expert--and Missing Manual series creator--David Pogue. Totally objective and utterly in-the-know, Pogue highlights the newest features, changes, and improvements of iLife '05, covers the capabilities and limitations of each program within the suite, and delivers count

  14. Absence of missing mass in clusters

    Energy Technology Data Exchange (ETDEWEB)

    Fesenko, B.I.

    1981-01-01

    The evaluation of the radial-velocity dispersion in clusters of galaxies is considered by using order statistics to reduce the distortions introduced by foreground and background galaxies and by large errors in velocity measurement. For four nearby clusters of galaxies, including the Coma cluster, velocity dispersions are obtained which are approximately four times lower than previously reported values. It is found that more remote galaxies exhibit the same tendency to a reduction in missing mass. A detailed examination of the statistical properties of galaxies in the Virgo cluster reveals that the cluster might not actually exist, but may be just a large excess in the number density of bright galaxies, possibly the result of an increase in the visibility of objects in the appropriate directions. It is concluded that the presence of a large amount of missing mass in clusters of galaxies is yet to be proven.

  15. THE RHIC INJECTION SYSTEM.

    Energy Technology Data Exchange (ETDEWEB)

    FISCHER,W.; GLENN,J.W.; MACKAY,W.W.; PTITSIN,V.; ROBINSON,T.G.; TSOUPAS,N.

    1999-03-29

    The RHIC injection system has to transport beam from the AGS-to-RHIC transfer line onto the closed orbits of the RHIC Blue and Yellow rings. This task can be divided into three problems. First, the beam has to be injected into either ring. Second, once injected the beam needs to be transported around the ring for one turn. Third, the orbit must be closed and coherent beam oscillations around the closed orbit should be minimized. We describe our solutions for these problems and report on system tests conducted during the RHIC Sextant test performed in 1997. The system will be fully commissioned in 1999.

  16. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    2014-01-01

    We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used in an inject......We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used...

  17. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used in an inject......We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used...

  18. MOLDOVA: MISSED ADVANTAGES OF EURASIAN INTEGRATION

    Directory of Open Access Journals (Sweden)

    Ludmila Vasiljevna Fokina

    2015-01-01

    Full Text Available The article is devoted to potentially missed advantages of Eurasian integration (EAEU for Moldova. Special attention is given to the branches in which the country could get evident advantages including agriculture, power engineering, external trade ties with the EAEU countries. Possible positive effects of Eurasian integration in solution of the Transnistrian problem, in the sphere of labour migration and other fields are also shown.

  19. Photoshop Elements 6 The Missing Manual

    CERN Document Server

    Brundage, Barbara

    2009-01-01

    With Photoshop Elements 6, the most popular photo-editing program on Earth just keeps getting better. It's perfect for scrapbooking, email-ready slideshows, Web galleries, you name it. But knowing what to do and when is tricky. That's why our Missing Manual is the bestselling book on the topic. This fully revised guide explains not only how the tools and commands work, but when to use them.

  20. Missing level corrections using neutron spacings

    International Nuclear Information System (INIS)

    Mitchell, G.E.; Shriner, J.F. Jr.

    2009-11-01

    Nuclear level densities are very important for a wide variety of pure and applied neutron physics. Most of the relevant information is obtained from neutron resonance data. The key correction to the raw experimental data is for missing levels. All of the standard correction methods assume that the neutron resonances obey the predictions of the Gaussian Orthogonal Ensemble version of Random Matrix Theory (RMT) and utilize comparison with the Porter-Thomas distribution of reduced widths in order to determine the fraction of missing levels. Here we adopt an alternate approach, comparing the neutron data with the predictions of RMT for eigenvalue statistics. Since in RMT the widths and eigenvalues are independent, analysis of the eigenvalues provides an independent analysis of the same data set. We summarize recent work in this area using the nearest neighbour spacing distribution, and we also develop tests that utilize several other eigenvalue statistics to provide additional estimates of the missing fraction of levels. These additional statistics include the key test for long range order - the Dyson-Mehta Δ 3 statistic - as well as the thermodynamic energy (that arises from Dyson's Circular Orthogonal Ensemble), the linear correlation coefficient of adjacent spacings (a measure of short range anti-correlation), and a statistic related to the Q statistic defined by Dyson and Mehta in the early 1960s. Developed FORTRAN code is available at http://www-nds.iaea.org/missing-levels/. These tests are applied to the s-wave neutron resonances in n + 238 U and n + 232 Th. The results for 238 U are consistent with each other and raise some issues concerning data purity. For the 232 Th data, all of the tests are in excellent agreement. (author)

  1. iWork '09 The Missing Manual

    CERN Document Server

    Clark, Josh

    2009-01-01

    With iWork '09: The Missing Manual, you'll quickly learn everything you need to know about Apple's incredible productivity programs, including the Pages word-processor, the Numbers spreadsheet, and the Keynote presentation program that Al Gore and Steve Jobs made famous. This book gives you crystal-clear and jargon-free explanations of iWork's capabilities, advantages, and limitations to help you produce stunning documents and cinema-quality digital presentations in no time.

  2. Uncovering missing links with cold ends

    Science.gov (United States)

    Zhu, Yu-Xiao; Lü, Linyuan; Zhang, Qian-Ming; Zhou, Tao

    2012-11-01

    To evaluate the performance of prediction of missing links, the known data are randomly divided into two parts, the training set and the probe set. We argue that this straightforward and standard method may lead to terrible bias, since in real biological and information networks, missing links are more likely to be links connecting low-degree nodes. We therefore study how to uncover missing links with low-degree nodes, namely links in the probe set are of lower degree products than a random sampling. Experimental analysis on ten local similarity indices and four disparate real networks reveals a surprising result that the Leicht-Holme-Newman index [E.A. Leicht, P. Holme, M.E.J. Newman, Vertex similarity in networks, Phys. Rev. E 73 (2006) 026120] performs the best, although it was known to be one of the worst indices if the probe set is a random sampling of all links. We further propose an parameter-dependent index, which considerably improves the prediction accuracy. Finally, we show the relevance of the proposed index to three real sampling methods: acquaintance sampling, random-walk sampling and path-based sampling.

  3. MISSE 6 Polymer Film Tensile Experiment

    Science.gov (United States)

    Miller, Sharon K. R.; Dever, Joyce A.; Banks, Bruce A.; Waters, Deborah L.; Sechkar, Edward; Kline, Sara

    2010-01-01

    The Polymer Film Tensile Experiment (PFTE) was flown as part of Materials International Space Station Experiment 6 (MISSE 6). The purpose of the experiment was to expose a variety of polymer films to the low Earth orbital environment under both relaxed and tension conditions. The polymers selected are those commonly used for spacecraft thermal control and those under consideration for use in spacecraft applications such as sunshields, solar sails, and inflatable and deployable structures. The dog-bone shaped samples of polymers that were flown were exposed on both the side of the MISSE 6 Passive Experiment Container (PEC) that was facing into the ram direction (receiving atomic oxygen, ultraviolet (UV) radiation, ionizing radiation, and thermal cycling) and the wake facing side (which was supposed to have experienced predominantly the same environmental effects except for atomic oxygen which was present due to reorientation of the International Space Station). A few of the tensile samples were coated with vapor deposited aluminum on the back and wired to determine the point in the flight when the tensile sample broke as recorded by a change in voltage that was stored on battery powered data loggers for post flight retrieval and analysis. The data returned on the data loggers was not usable. However, post retrieval observation and analysis of the samples was performed. This paper describes the preliminary analysis and observations of the polymers exposed on the MISSE 6 PFTE.

  4. UV-visible digital imaging of split injection in a Gasoline Direct Injection engine

    Directory of Open Access Journals (Sweden)

    Merola Simona Silvia

    2015-01-01

    Full Text Available Ever tighter limits on pollutant emissions and the need to improve energy conversion efficiency have made the application of gasoline direct injection (GDI feasible for a much wider scale of spark ignition engines. Changing the way fuel is delivered to the engine has thus provided increased flexibility but also challenges, such as higher particulate emissions. Therefore, alternative injection control strategies need to be investigated in order to obtain optimum performance and reduced environmental impact. In this study, experiments were carried out on a single-cylinder GDI optical engine fuelled with commercial gasoline in lean-burn conditions. The single-cylinder was equipped with the head of a commercial turbocharged engine with similar geometrical specifications (bore, stroke, compression ratio and wall guided fuel injection. Optical accessibility was ensured through a conventional elongated hollow Bowditch piston and an optical crown, accommodating a fused-silica window. Experimental tests were performed at fixed engine speed and injection pressure, whereas the injection timing and the number of injections were adjusted to investigate their influence on combustion and emissions. UV-visible digital imaging was applied in order to follow the combustion process, from ignition to the late combustion phase. All the optical data were correlated with thermodynamic analysis and measurements of exhaust emissions. Split injection strategies (i.e. two injections per cycle with respect to single injection increased combustion efficiency and stability thanks to an improvement of fuel air mixing. As a consequence, significant reduction in soot formation and exhaust emission with acceptable penalty in terms of HC and NOx were measured.

  5. Characterization equipment essential drawing plan

    International Nuclear Information System (INIS)

    WILSON, G.W.

    1999-01-01

    The purpose of this document is to list the Characterization equipment drawings that are classified as Essential Drawings. Essential Drawings: Are those drawings identified by the facility staff as necessary to directly support the safe operation of the facility or equipment (HNF 1997a). The Characterization equipment drawings identified in this report are deemed essential drawings as defined in HNF-PRO-242, Engineering Drawing Requirements (HNF 1997a). These drawings will be prepared, revised, and maintained per HNF-PRO-440, Engineering Document Change Control (HNF 1997b). All other Characterization equipment drawings not identified in this document will be considered Support drawings until the Characterization Equipment Drawing Evaluation Report is completed

  6. Coal mining equipment

    International Nuclear Information System (INIS)

    Stein, R.R.; Martin, T.W.

    1991-01-01

    The word in longwall components is big, and these larger components have price tags to match. The logic behind the greater investment is that it will yield high production rates and good uptime statistics. This is true in most cases. More important than single-shift tonnage records, average shift production continues to climb upwards. This paper reports on the quality, and more significantly, the quantity of service supplied for long-wall equipment, which has reached levels that would have been seen as unachievable when longwall mining was first introduced in the U.S. The school of thought then was that longwall would increase productivity in part by reducing the number of production units and thus reducing the number of personnel employed underground. The expectation of fewer employees turned out to be unrealistic. That was probably one reason that some early attempts to install longwall system looked more like failures than vision of the future

  7. Reactor fuel charging equipment

    International Nuclear Information System (INIS)

    Wade, Elman.

    1977-01-01

    In many types of reactor fuel charging equipment, tongs or a grab, attached to a trolley, housed in a guide duct, can be used for withdrawing from the core a selected spent fuel assembly or to place a new fuel assembly in the core. In these facilities, the trolley may have wheels that roll on rails in the guide duct. This ensures the correct alignment of the grab, the trolley and fuel assembly when this fuel assembly is being moved. By raising or lowering such a fuel assembly, the trolley can be immerged in the coolant bath of the reactor, whereas at other times it can be at a certain level above the upper surface of the coolant bath. The main object of the invention is to create a fuel handling apparatus for a sodium cooled reactor with bearings lubricated by the sodium coolant and in which the contamination of these bearings is prevented [fr

  8. Planned Missing Data Designs in Educational Psychology Research

    NARCIS (Netherlands)

    Rhemtulla, M.; Hancock, G.R.

    2016-01-01

    Although missing data are often viewed as a challenge for applied researchers, in fact missing data can be highly beneficial. Specifically, when the amount of missing data on specific variables is carefully controlled, a balance can be struck between statistical power and research costs. This

  9. Process control and product evaluation in micro molding using a screwless/two-plunger injection unit

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Dormann, B.

    2010-01-01

    A newly developed μ-injection molding machine equipped with a screwless/two-plunger injection unit has been employed to mould miniaturized dog-bone shaped specimens on polyoxymethylene and its process capability and robustness have been analyzed. The influence of process parameters on μ-injection......A newly developed μ-injection molding machine equipped with a screwless/two-plunger injection unit has been employed to mould miniaturized dog-bone shaped specimens on polyoxymethylene and its process capability and robustness have been analyzed. The influence of process parameters on μ......-injection molding was investigated using the Design of Experiments technique. Injection pressure and piston stroke speed as well as part weight and dimensions were considered as quality factors over a wide range of process parameters. Experimental results obtained under different processing conditions were...

  10. Hip joint injection

    Science.gov (United States)

    ... medicine into the joint. The provider uses a real-time x-ray (fluoroscopy) to see where to place ... Wakefield RJ. Arthrocentesis and injection of joints and soft tissue. In: Firestein GS, Budd RC, Gabriel SE, ...

  11. Premixed direct injection disk

    Science.gov (United States)

    York, William David; Ziminsky, Willy Steve; Johnson, Thomas Edward; Lacy, Benjamin; Zuo, Baifang; Uhm, Jong Ho

    2013-04-23

    A fuel/air mixing disk for use in a fuel/air mixing combustor assembly is provided. The disk includes a first face, a second face, and at least one fuel plenum disposed therebetween. A plurality of fuel/air mixing tubes extend through the pre-mixing disk, each mixing tube including an outer tube wall extending axially along a tube axis and in fluid communication with the at least one fuel plenum. At least a portion of the plurality of fuel/air mixing tubes further includes at least one fuel injection hole have a fuel injection hole diameter extending through said outer tube wall, the fuel injection hole having an injection angle relative to the tube axis. The invention provides good fuel air mixing with low combustion generated NOx and low flow pressure loss translating to a high gas turbine efficiency, that is durable, and resistant to flame holding and flash back.

  12. Imipenem and Cilastatin Injection

    Science.gov (United States)

    Imipenem and cilastatin injection is used to treat certain serious infections that are caused by bacteria, including ... area), gynecological, blood, skin, bone, and joint infections. Imipenem is in a class of medications called carbapenem ...

  13. Quinupristin and Dalfopristin Injection

    Science.gov (United States)

    ... are in a class of medications called streptogramin antibiotics. They work by killing bacteria that cause infections.Antibiotics such as quinupristin and dalfopristin injection will not work for colds, flu, or other viral infections. Taking ...

  14. Botulinum toxin injection - larynx

    Science.gov (United States)

    Injection laryngoplasty; Botox - larynx: spasmodic dysphonia-BTX; Essential voice tremor (EVT)-btx; Glottic insufficiency; Percutaneous electromyography - guided botulinum toxin treatment; Percutaneous indirect laryngoscopy - guided botulinum toxin treatment; ...

  15. The PEP injection system

    International Nuclear Information System (INIS)

    Brown, K.L.; Avery, R.T.; Peterson, J.M.

    1988-01-01

    A system to transport 10-to-15-GeV electron and positron beams from the Stanford Linear Accelerator and to inject them into the PEP storage ring under a wide variety of lattice configurations has been designed. Optically, the transport line consists of three 360/degree/ phase-shift sections of FODO lattice, with bending magnets interspersed in such a way as to provide achromaticity, convenience in energy and emittance definition, and independent tuning of the various optical parameters for matching into the ring. The last 360/degree/ of phase shift has 88 milliradians of bend in a vertical plane and deposits the beam at the injection septum via a Lambertson magnet. Injection is accomplished by launching the beam with several centimeters of radial betatron amplitude in a fast bump provided by a triad of pulsed kicker magnets. Radiation damping reduces the collective amplitude quickly enough to allow injection at a high repetition rate

  16. Missing value imputation for epistatic MAPs

    LENUS (Irish Health Repository)

    Ryan, Colm

    2010-04-20

    Abstract Background Epistatic miniarray profiling (E-MAPs) is a high-throughput approach capable of quantifying aggravating or alleviating genetic interactions between gene pairs. The datasets resulting from E-MAP experiments typically take the form of a symmetric pairwise matrix of interaction scores. These datasets have a significant number of missing values - up to 35% - that can reduce the effectiveness of some data analysis techniques and prevent the use of others. An effective method for imputing interactions would therefore increase the types of possible analysis, as well as increase the potential to identify novel functional interactions between gene pairs. Several methods have been developed to handle missing values in microarray data, but it is unclear how applicable these methods are to E-MAP data because of their pairwise nature and the significantly larger number of missing values. Here we evaluate four alternative imputation strategies, three local (Nearest neighbor-based) and one global (PCA-based), that have been modified to work with symmetric pairwise data. Results We identify different categories for the missing data based on their underlying cause, and show that values from the largest category can be imputed effectively. We compare local and global imputation approaches across a variety of distinct E-MAP datasets, showing that both are competitive and preferable to filling in with zeros. In addition we show that these methods are effective in an E-MAP from a different species, suggesting that pairwise imputation techniques will be increasingly useful as analogous epistasis mapping techniques are developed in different species. We show that strongly alleviating interactions are significantly more difficult to predict than strongly aggravating interactions. Finally we show that imputed interactions, generated using nearest neighbor methods, are enriched for annotations in the same manner as measured interactions. Therefore our method potentially

  17. Critical incidents and near misses during anesthesia: A prospective audit

    Directory of Open Access Journals (Sweden)

    Pamela Onorame Agbamu

    2017-01-01

    Full Text Available Background: A critical incident is any preventable mishap associated with the administration of anesthesia and which leads to or could have led to an undesirable patients' outcome. Patients' safety can be improved by learning from reported critical incidents and near misses. Materials and Methods: All perioperative critical incidents (excluding obstetrics occurring over 5 months were voluntarily documented in a pro forma. Age of patient, urgency of surgery, grade of anesthetist, and patients' outcome was noted. Results: Seventy-three critical incidents were recorded in 42 patients (incidence 6.1% of 1188 procedures with complete recovery in 88.1% (n = 37 and mortality in 11.9% (n = 5. The highest incidents occurred during elective procedures (71.4%, which were all supervised by consultants, and in patients aged 0–10 years (40.1%. Critical incident categories documented were cardiovascular (41.1%, respiratory (23.25%, vascular access (15.1%, airway/intubation (6.85%, equipment errors (6.85%, difficult/failed regional technique (4.11%, and others (2.74%. The monitors available were: pulse oximetry (100%, precordial stethoscope (90.5%, sphygmomanometer (90.5%, capnography (54.8%, electrocardiogram (31%, and temperature (14.3%. The most probable cause of critical incident was patient factor (38.7% followed by human error (22.5%. Equipment error, pharmacological factor, and surgical factor accounted for 12.9%. Conclusion: Critical incidents can occur in the hands of the highly skilled and even in the presence of adequate monitoring. Protocols should be put in place to avoid errors. Critical incident reporting must be encouraged to improve patients' safety and reduce morbidity and mortality.

  18. Chapter 12. Space Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.

    1998-01-01

    The performance evaluation of space heating equipment for a geothermal application is generally considered from either of two perspectives: (a) selecting equipment for installation in new construction, or (b) evaluating the performance and retrofit requirements of an existing system. With regard to new construction, the procedure is relatively straightforward. Once the heating requirements are determined, the process need only involve the selection of appropriately sized hot water heating equipment based on the available water temperature. It is important to remember that space heating equipment for geothermal applications is the same equipment used in non-geothermal applications. What makes geothermal applications unique is that the equipment is generally applied at temperatures and flow rates that depart significantly from traditional heating system design. This chapter presents general considerations for the performance of heating equipment at non-standard temperature and flow conditions, retrofit of existing systems, and aspects of domestic hot water heating.

  19. A missing-bending-magnet scheme for PEP

    International Nuclear Information System (INIS)

    Liu, R.Z.; Winick, H.

    1988-01-01

    This article presents a missing-bending-magnet scheme for PEP as a modification that could be considered if PEP were available as a fully dedicated synchrotron radiation source. The scheme can be applied to one or more PEP sextants without changing the rest. By removing some bending magnets, rearranging the remaining magnets, and adding two quadrupoles, ten additional straight sections per sextant can be created, each 5 m or more in length, for insertion devices. Beam lines therefrom, plus possible beam lines from bending magnets would enter a continuous experimental hall instead of individual tunnels and halls for each beam line. This should result in construction cost savings and increased operations efficiency. The ideal beam orbit is unchanged at the two ends and the middle of the sextant. At the end of the curved part of the sextant the lattice functions match those of the long interaction region straight section in the low emittance configuration of PEP. The electron beam characteristics in the newly created straight sections are described, including the enlargement of the horizontal beam size due to the nonzero dispersion. Some disadvantages of the scheme are increased operations complexity due to the need for nine new quadrupole families, increased beam emittance (by 14.5% is one sextant is modified), and reduced dynamic aperture. However, the dynamic aperture is still about as large as the physical aperture and should be adequate for good beam lifetime and injection. (orig.)

  20. Risk Factors Associated with Unsafe Injection Practices at the First Injection Episode among Intravenous Drug Users in France: Results from PrimInject, an Internet Survey.

    Science.gov (United States)

    Guichard, Anne; Guignard, Romain; Lert, France; Roy, Elise

    2015-01-01

    Background. New drug use patterns may increase the risk of human immunodeficiency virus and hepatitis infections. In France, new injection patterns among youths with diverse social backgrounds have emerged, which may explain the persistently high rates of hepatitis C virus infection. This study explores factors associated with injection risk behaviours at first injection among users who began injecting in the post-2000 era. Methods. A cross-sectional study was conducted on the Internet from October 2010 to March 2011, through an online questionnaire. Multivariate logistic regression identified the independent correlates of needle sharing and equipment (cooker/cotton filter) sharing. Results. Among the 262 respondents (mean age 25 years), 65% were male. Both risk behaviours were positively associated with initiation before 18 years of age (aOR 3.7 CI 95% 1.3-10.6 and aOR 3.0 CI 95% 1.3-7.0) and being injected by another person (aOR 3.1 CI 95% 1.0-9.9 and aOR 3.0 CI 95% 1.3-7.1). Initiation at a party was an independent correlate of equipment sharing (aOR 2.6 95% CI 1.0-6.8). Results suggest a need for innovative harm reduction programmes targeting a variety of settings and populations, including youths and diverse party scenes. Education of current injectors to protect both themselves and those they might initiate into injection is critically important.

  1. Equipment repair in coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, S

    1982-01-01

    Most equipment in Chinese coal mines consists of machinery and equipment produced in the 1950s; the efficiency of 4-62, CTD-57 and 70B/sub 2/ ventilators is 15% lower than that of new ones; that of SSM and AYaP pumps, 10% lower than of modern ones. Equipment renovation is done in three ways: replacing obsolete equipment with new equipment of the same type; improving the performance of existing equipment by introducing efficiency and reconstruction; and replacing obsolete equipment with advanced equipment. It is indicated that the second way, for example, replacement of 4-62 ventilator blades with a maximum efficiency of 73% by 4-72 ventilator blades raises its efficiency to 90%. Replacing the 8DA-8x3 water pump, having a maximum efficiency of 63%, with the 200D 43x3 pump with a maximum efficiency of 78%, enables an electricity savings of 7000 yuan per year, which exceeds all replacement costs (600 yuan). The need to improve equipment maintenance and preventive work to increase equipment service life and to introduce new techniques and efficiency is noted.

  2. CDC Vital Signs–HIV and Injection Drug Use

    Centers for Disease Control (CDC) Podcasts

    This podcast is based on the December 2016 CDC Vital Signs report. Sharing needles, syringes, and other injection equipment puts you at risk for getting HIV and other infections, including hepatitis. Learn how to reduce your HIV risk.

  3. AUTOMATIC CLASSIFICATION OF VARIABLE STARS IN CATALOGS WITH MISSING DATA

    International Nuclear Information System (INIS)

    Pichara, Karim; Protopapas, Pavlos

    2013-01-01

    We present an automatic classification method for astronomical catalogs with missing data. We use Bayesian networks and a probabilistic graphical model that allows us to perform inference to predict missing values given observed data and dependency relationships between variables. To learn a Bayesian network from incomplete data, we use an iterative algorithm that utilizes sampling methods and expectation maximization to estimate the distributions and probabilistic dependencies of variables from data with missing values. To test our model, we use three catalogs with missing data (SAGE, Two Micron All Sky Survey, and UBVI) and one complete catalog (MACHO). We examine how classification accuracy changes when information from missing data catalogs is included, how our method compares to traditional missing data approaches, and at what computational cost. Integrating these catalogs with missing data, we find that classification of variable objects improves by a few percent and by 15% for quasar detection while keeping the computational cost the same

  4. AUTOMATIC CLASSIFICATION OF VARIABLE STARS IN CATALOGS WITH MISSING DATA

    Energy Technology Data Exchange (ETDEWEB)

    Pichara, Karim [Computer Science Department, Pontificia Universidad Católica de Chile, Santiago (Chile); Protopapas, Pavlos [Institute for Applied Computational Science, Harvard University, Cambridge, MA (United States)

    2013-11-10

    We present an automatic classification method for astronomical catalogs with missing data. We use Bayesian networks and a probabilistic graphical model that allows us to perform inference to predict missing values given observed data and dependency relationships between variables. To learn a Bayesian network from incomplete data, we use an iterative algorithm that utilizes sampling methods and expectation maximization to estimate the distributions and probabilistic dependencies of variables from data with missing values. To test our model, we use three catalogs with missing data (SAGE, Two Micron All Sky Survey, and UBVI) and one complete catalog (MACHO). We examine how classification accuracy changes when information from missing data catalogs is included, how our method compares to traditional missing data approaches, and at what computational cost. Integrating these catalogs with missing data, we find that classification of variable objects improves by a few percent and by 15% for quasar detection while keeping the computational cost the same.

  5. Missing value imputation: with application to handwriting data

    Science.gov (United States)

    Xu, Zhen; Srihari, Sargur N.

    2015-01-01

    Missing values make pattern analysis difficult, particularly with limited available data. In longitudinal research, missing values accumulate, thereby aggravating the problem. Here we consider how to deal with temporal data with missing values in handwriting analysis. In the task of studying development of individuality of handwriting, we encountered the fact that feature values are missing for several individuals at several time instances. Six algorithms, i.e., random imputation, mean imputation, most likely independent value imputation, and three methods based on Bayesian network (static Bayesian network, parameter EM, and structural EM), are compared with children's handwriting data. We evaluate the accuracy and robustness of the algorithms under different ratios of missing data and missing values, and useful conclusions are given. Specifically, static Bayesian network is used for our data which contain around 5% missing data to provide adequate accuracy and low computational cost.

  6. Are We Really Missing Small Galaxies?

    Science.gov (United States)

    Kohler, Susanna

    2018-02-01

    One long-standing astrophysical puzzle is that of so-called missing dwarf galaxies: the number of small dwarf galaxies that we observe is far fewer than that predicted by theory. New simulations, however, suggest that perhaps theres no mystery after all.Missing DwarfsDark-matter cosmological simulations predict many small galaxy halos for every large halo that forms. [The Via Lactea project]Models of a lambda-cold-dark-matter (CDM) universe predict the distribution of galaxy halo sizes throughout the universe, suggesting there should be many more small galaxies than large ones. In what has become known as the missing dwarf problem, however, we find that while we observe the expected numbers of galaxies at the larger end of the scale, we dont see nearly enough small galaxies to match the predictions.Are these galaxies actually missing? Are our predictions wrong? Or are the galaxies there and were just not spotting them? A recent study led by Alyson Brooks (Rutgers University) uses new simulations to explore whatscausing the difference between theory and observation.The fraction of detectable halos as a function of velocity, according to the authors simulations. Below 35 km/s, the detectability of the galaxies drops precipitously. [Brooks et al. 2017]Simulating Galactic VelocitiesBecause we cant weigh a galaxy directly, one proxy used for galaxy mass is its circular velocity; the more massive a galaxy, the faster gas and stars rotate around its center. The discrepancy between models and observations lies in whats known as the galaxy velocity function, which describes the number density of galaxies for a given circular velocity. While theory and observations agree for galaxies with circular velocities above 100 km/s, theory predicts far more dwarfs below this velocity than we observe.To investigate this problem, Brooks and collaborators ran a series of cosmological simulations based on our understanding of a CDM universe. Instead of exploring the result using only

  7. 21 CFR 866.4540 - Immunonephelometer equipment.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866.4540 Immunonephelometer equipment. (a) Identification. Immunonephelometer equipment for clinical use...

  8. 21 CFR 866.4520 - Immunofluorometer equipment.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866.4520 Immunofluorometer equipment. (a) Identification. Immunofluorometer equipment for clinical use with...

  9. Syringe injectable electronics

    Science.gov (United States)

    Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M.

    2015-01-01

    Seamless and minimally-invasive three-dimensional (3D) interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating syringe injection and subsequent unfolding of submicrometer-thick, centimeter-scale macroporous mesh electronics through needles with a diameter as small as 100 micrometers. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with > 90% device yield. We demonstrate several applications of syringe injectable electronics as a general approach for interpenetrating flexible electronics with 3D structures, including (i) monitoring of internal mechanical strains in polymer cavities, (ii) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (iii) in vivo multiplexed neural recording. Moreover, syringe injection enables delivery of flexible electronics through a rigid shell, delivery of large volume flexible electronics that can fill internal cavities and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics. PMID:26053995

  10. Syringe-injectable electronics.

    Science.gov (United States)

    Liu, Jia; Fu, Tian-Ming; Cheng, Zengguang; Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M

    2015-07-01

    Seamless and minimally invasive three-dimensional interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating the syringe injection (and subsequent unfolding) of sub-micrometre-thick, centimetre-scale macroporous mesh electronics through needles with a diameter as small as 100 μm. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with >90% device yield. We demonstrate several applications of syringe-injectable electronics as a general approach for interpenetrating flexible electronics with three-dimensional structures, including (1) monitoring internal mechanical strains in polymer cavities, (2) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (3) in vivo multiplexed neural recording. Moreover, syringe injection enables the delivery of flexible electronics through a rigid shell, the delivery of large-volume flexible electronics that can fill internal cavities, and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics.

  11. iPod the missing manual

    CERN Document Server

    Biersdorfer, J D

    2008-01-01

    With the tiny Shuffle, the Nano, the Classic, or the Touch, Apple's gotten the world hooked on portable music, pictures, videos -- and the iPod. One thing they haven't delivered is an easy guide for getting the most from this sleek entertainment center. iPod: The Missing Manual, 7th Edition gives you a no-nonsense view of the latest iPod line, with crystal-clear explanations, easy-to-follow color graphics, and guidance on the most useful things your iPod can do.

  12. Switching to the Mac The Missing Manual

    CERN Document Server

    Pogue, David

    2010-01-01

    Is Windows giving you pause? Ready to make the leap to the Mac instead? There has never been a better time to switch from Windows to Mac, and this incomparable guide will help you make a smooth transition. New York Times columnist and Missing Manuals creator David Pogue gets you past three challenges: transferring your stuff, assembling Mac programs so you can do what you did with Windows, and learning your way around Mac OS X. Learning to use a Mac is not a piece of cake, but once you do, the rewards are oh-so-much better. No viruses, worms, or spyware. No questionable firewalls, inefficien

  13. Dreamweaver CS55 The Missing Manual

    CERN Document Server

    McFarland, David

    2011-01-01

    Dreamweaver is the tool most widely used for designing and managing professional-looking websites, but it's a complex program. That's where Dreamweaver CS5.5: The Missing Manual comes in. With its jargon-free explanations, 13 hands-on tutorials, and savvy advice from Dreamweaver expert Dave McFarland, you'll master this versatile program with ease. Get A to Z guidance. Go from building your first web page to creating interactive, database-driven sites.Build skills as you learn. Apply your knowledge through tutorials and downloadable practice files.Create a state-of-the-art website. Use powerf

  14. Handling missing data in ranked set sampling

    CERN Document Server

    Bouza-Herrera, Carlos N

    2013-01-01

    The existence of missing observations is a very important aspect to be considered in the application of survey sampling, for example. In human populations they may be caused by a refusal of some interviewees to give the true value for the variable of interest. Traditionally, simple random sampling is used to select samples. Most statistical models are supported by the use of samples selected by means of this design. In recent decades, an alternative design has started being used, which, in many cases, shows an improvement in terms of accuracy compared with traditional sampling. It is called R

  15. Flash CS5 The Missing Manual

    CERN Document Server

    Grover, Chris

    2010-01-01

    Once you know how to use Flash, you can create everything from simple animations to high-end desktop applications, but it's a complex tool that can be difficult to master on your own-unless you have this Missing Manual. This book will help you learn all you need to know about Flash CS5 to create animations that bring your ideas to life. Learn animation basics. Find everything you need to know to get started with FlashMaster the Flash tools. Learn the animation and effects toolset, with clear explanations and hands-on examplesUse 3D effects. Rotate and put objects in motion in three dimensions

  16. Droid X2 The Missing Manual

    CERN Document Server

    Gralla, Preston

    2011-01-01

    Droid X2 has more power and better graphics than its predecessor, but it still doesn't offer a printed guide to its amazing features. This Missing Manual helps you dig deep into everything Droid X2 can do. Learn how to shop, keep in touch, play with photos, listen to music, and even do some work. Unleash the power of this popular device with expert advice. The important stuff you need to know: Get organized. Sync Droid X2 with Google Calendar, Exchange, and Outlook.Go online. Navigate the Web, use email, and tap into Facebook and Twitter.Listen to tunes. Play and manage music using Droid X2'

  17. Creating a Website The Missing Manual

    CERN Document Server

    MacDonald, Matthew

    2011-01-01

    Think you need an army of skilled programmers to build a website? Think again. With nothing more than an ordinary PC, some raw ambition, and this book, you'll learn how to create and maintain a professional-looking, visitor-friendly site. This Missing Manual gives you all the tools, techniques, and expert advice you need. Plan your site. Create web pages by learning the basics of HTML and HTML5.Control page design with CSS. Format text, images, links, tables, and other elements.Attract visitors. Ensure that people can find your site through popular search engines.Build a community. Add forums

  18. Creating a web site the missing manual

    CERN Document Server

    MacDonald, Matthew

    2008-01-01

    Think you have to be a technical wizard to build a great web site? Think again. If you want to create an engaging web site, this thoroughly revised, completely updated edition of Creating a Web Site: The Missing Manual demystifies the process and provides tools, techniques, and expert guidance for developing a professional and reliable web presence. Whether you want to build a personal web site, an e-commerce site, a blog, or a web site for a specific occasion or promotion, this book gives you detailed instructions and clear-headed advice for: Everything from planning to launching. From pi

  19. Windows Vista for Starters The Missing Manual

    CERN Document Server

    Pogue, David

    2010-01-01

    Fast-paced and easy to use, this concise book teaches you the basics of Windows Vista so you can start using this operating system right away. Written by "New York Times" columnist, bestselling author, Emmy-winning CBS News correspondent and Missing Manuals creator David Pogue, the book will help you: Navigate the desktop, including the fast, powerful and fully integrated desktop search functionUse the Media Center to record TV and radio, present photos, play music, and record all of these to a DVDBreeze across the Web with the vastly improved Internet Explorer 7 tabbed browserBecome familiar

  20. Equipment standards for interventional cardiology

    International Nuclear Information System (INIS)

    Dowling, A.; Gallagher, A.; Walsh, C.; Malone, J.

    2005-01-01

    Interventional radiology has seen rapid growth in cardiology and represents an alternative to hazardous surgery. Recently there has been a substantial growth in the number of procedures being performed and interventional cardiology (IC) procedures are the most common interventional procedures in Europe. Advances in imaging technology have facilitated the development of increasingly complex radiological IC equipment. Currently, the technology is developing at a rate ahead of supporting research, equipment standards and a regulatory framework. International standards play a key role in the design, manufacture and performance of radiological IC equipment. A survey of 12 IC systems (15 imaging chains) was conducted in Irish hospitals. The aim of the study was to assess the imbalance between rapidly advancing technology and existing standards and to propose recommendations for new IC equipment standards. The results demonstrate the need for definitive equipment requirements and standardisation in the design, manufacture, acceptance and maintenance of IC equipment. (authors)

  1. Knowledge, Attitude and Practice of Injection Safety among Benue ...

    African Journals Online (AJOL)

    adedamla

    syringes without sterilization. ... Injection safety as a concept includes all actions that ... access safe, affordable equipment to promote the ... Hospital. MATERIALS AND METHODS ... latitude 7043'N and longitude 8034'E. The hospital ... respondents personal experience of the consequences of .... facilities in Nigeria in 2004.

  2. Injection safety practices among resident doctors in a tertiary health ...

    African Journals Online (AJOL)

    2013-11-20

    Nov 20, 2013 ... E‑mail: drbecky4flex@yahoo.com. Introduction. Injection is one of ... materials, inadequate facilities for sterilization as well as an average of 4.9 .... protective equipment (PPE), safety boxes at strategic locations in the hospital ...

  3. Generation of equipment response spectrum considering equipment-structure interaction

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Yoo, Kwang Hoon

    2005-01-01

    Floor response spectra for dynamic response of subsystem such as equipment, or piping in nuclear power plant are usually generated without considering dynamic interaction between main structure and subsystem. Since the dynamic structural response generally has the narrow-banded shapes, the resulting floor response spectra developed for various locations in the structure usually have high spectral peak amplitudes in the narrow frequency bands corresponding to the natural frequencies of the structural system. The application of such spectra for design of subsystems often leads to excessive design conservatisms, especially when the equipment frequency and structure are at resonance condition. Thus, in order to provide a rational and realistic design input for dynamic analysis and design of equipment, dynamic equipment-structure interaction (ESI) should be considered in developing equipment response spectrum which is particularly important for equipment at the resonance condition. Many analytical methods have been proposed in the past for developing equipment response spectra considering ESI. However, most of these methods have not been adapted to the practical applications because of either the complexities or the lack of rigorousness of the methods. At one hand, mass ratio among the equipment and structure was used as an important parameter to obtain equipment response spectra. Similarly, Tseng has also proposed the analytical method for developing equipment response spectra using mass ratio in the frequency domain. This method is analytically rigorous and can be easily validated. It is based on the dynamic substructuring method as applied to the dynamic soil-structure interaction (SSI) analysis, and can relatively easily be implemented for practical applications without to change the current dynamic analysis and design practice for subsystems. The equipment response spectra derived in this study are also based on Tseng's proposed method

  4. Overall Equipment Effectiveness Implementation Criteria

    Science.gov (United States)

    Abramova, I. G.; Abramov, D. A.

    2018-01-01

    This article documents the methods applied in production control technics specifically focused on commonly used parameter OEE (Overall Equipment Effectiveness). The indicators of extensive and intensive use of equipment are considered. Their appointment this is comparison in the same type of production within the industry and comparison of single-type and / or different types of equipment in terms of capacity. However, it is shown that there is no possibility of revealing the reasons for the machine’s operation: productive / unproductive, with disturbances. Therefore, in the article reveals the approaches to calculating the indicator characterizing the direct operation of the equipment. The Machine Load coefficient is approaching closely to the indicator of the efficiency of the use of equipment. Methods analysis is proceeded through the historically applied techniques such as “Stopwatch” and “Motion” studies. Was performed the analysis of the efficiency index of OEE equipment using the comparable indexes performance of equipment in the Russian practice. An important indicator of OEE contains three components. The meaning of each of them reflects historically applicable indicators. The value of the availability of equipment indicator is close to the value of the equipment extensibility index. The value of the indicator of the efficiency of work can be compared with the characteristic of the capacity of the equipment and the indicator of the quality level can meet the requirements for compliance with the manufacturing technology. Shown that the sum of the values of the coefficient of “Availability” of the equipment and the value of the “Factor of compaction of working hours” are one. As well as the total value of the indicator “level of quality” and the coefficient of marriage given in the result unit. The measurability of the indicators makes it possible to make a prediction about efficiency of the equipment.

  5. Water injection profiling by nuclear logging

    International Nuclear Information System (INIS)

    Arnold, D.M.

    1980-01-01

    This invention relates to nuclear logging techniques for determining the volume flow rates and flow directions of injected water moving behind a wellbore casing. The apparatus includes a sonde equipped with a neutron source and dual radiation detectors. Oxygen in the neutron irradiated water is transmitted to 16 N and the resultant primary and Compton scattered gamma rays are detected in two energy windows by both detectors. Count rate data is analysed in terms of the windows to obtain linear flow velocities for water flow within and behind the casing. Volume flow rates are determined for upward and downward flow, and horizontal volume flow into the surrounding formation is calculated. A complete injection profile may thus be obtained. (U.K.)

  6. Information technology equipment cooling system

    Science.gov (United States)

    Schultz, Mark D.

    2014-06-10

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools warm air generated by the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat from the rack of information technology equipment.

  7. Management methodology for pressure equipment

    Science.gov (United States)

    Bletchly, P. J.

    Pressure equipment constitutes a significant investment in capital and a major proportion of potential high-risk plant in many operations and this is particularly so in an alumina refinery. In many jurisdictions pressure equipment is also subject to statutory regulation that imposes obligations on Owners of the equipment with respect to workplace safety. Most modern technical standards and industry codes of practice employ a risk-based approach to support better decision making with respect to pressure equipment. For a management system to be effective it must demonstrate that risk is being managed within acceptable limits.

  8. Strategies for replacement of obsolete equipment - including reverse engineering

    International Nuclear Information System (INIS)

    Irish, C.S.

    2000-01-01

    The presentation shall detail the challenges facing nuclear power plants with the replacement of obsolete equipment and the strategies used to overcome those challenges. The presentation will outline the common equipment types which are either obsolete or are becoming obsolete, with a focus on safety related components. The four options of the obsolete equipment replacement philosophy will be presented with replacement examples from each of the options shown for discussion purposes. Detailed examples from each of the four obsolete equipment replacement options of: commercially available equivalent component; modification of a commercial available component; reverse engineering of the original component; and finally, design changes using a new component, shall be presented to evaluate the advantages and disadvantages of each option. The presentation will include the technical challenges, cost and schedule concerns for each of the four options. Emphasis will be placed on the technological challenges associated with replacing old and obsolete equipment. The following is a bullet list of the challenges which will be discussed: Missing, misleading or no information on the original component; Acquiring information from the original equipment manufacturer and the plant; Using a sample component for the replacement evaluation and or reverse engineering; and Reverse engineering old equipment with newly available discrete components. The presentation will include the equivalency documentation using the EPRI guidelines when replacing an original component with a different yet form, fit and functional equivalent component. The presentation will conclude with a discussion of the advantages and disadvantages of the replacement of the obsolete component with a form, fit and functional equivalent component vs. the replacement of the original component with a new component with today's technology. (author)

  9. Strategies for replacement of obsolete equipment, including reverse engineering

    International Nuclear Information System (INIS)

    Irish, C.S.

    2003-01-01

    The presentation shall detail the challenges facing nuclear power plants with the replacement of obsolete equipment and the strategies used to overcome those challenges. The presentation will outline the common equipment types which are either obsolete or are becoming obsolete, with a focus on safety related components. The four options of the obsolete equipment replacement philosophy will be presented with replacement examples from each of the options shown for discussion purposes. Detailed examples from each of the four obsolete equipment replacement options of, (1) commercially available equivalent component, (2) modification of a commercial available component, (3) reverse engineering of the original component and finally (4) design changes using a new component, shall be presented to evaluate the advantages and disadvantages of each option. The presentation will include the technical challenges, cost and schedule concerns for each of the four options. Emphasis will be placed on the technological challenges associated with replacing old and obsolete equipment. The following is a bullet list of the challenges which will be discussed: 1) Missing, misleading or no information on the original component. 2) Acquiring information from the original equipment manufacturer and the plant. 3) Using a sample component for the replacement evaluation and or reverse engineering. 4) Reverse engineering old equipment with newly available discrete components. The presentation will include the equivalency documentation using the EPRI guidelines when replacing an original component with a different yet form, fit and functional equivalent component. The presentation will conclude with a discussion of the advantages and disadvantages of the replacement of the obsolete component with a form, fit and functional equivalent component vs. the replacement of the original component with a new component with today's technology. (author)

  10. Reactor water injection facility

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kazuhiro; Kinoshita, Shoichiro

    1997-05-02

    A steam turbine and an electric generator are connected by way of a speed convertor. The speed convertor is controlled so that the number of rotation of the electric generator is constant irrespective of the speed change of the steam turbine. A shaft coupler is disposed between the turbine and the electric generator or between the turbine and a water injection pump. With such a constitution, the steam turbine and the electric generator are connected by way of the speed convertor, and since the number of revolution of the electric generator is controlled to be constant, the change of the number of rotation of the turbine can be controlled irrespective of the change of the number of rotation of the electric generator. Accordingly, the flow rate of the injection water from the water injection pump to a reactor pressure vessel can be controlled freely thereby enabling to supply stable electric power. (T.M.)

  11. Cryogenic equipment; Materiel cryogenique

    Energy Technology Data Exchange (ETDEWEB)

    Leger, L; Javellaud, J; Caro, C; Gilguy, R; Testard, O

    1966-06-01

    The cryostats presented here were built from standard parts; this makes it possible to construct a great variety of apparatus at minimum cost. The liquid nitrogen and helium reservoirs were designed so as to reduce losses to a minimum, and so as to make the cryostats as autonomous as possible. The experimental enclosure which is generally placed in the lower part of the apparatus requires a separate study in every case. Furthermore, complete assemblies such as transfer rods, isolated traps and high vacuum valves, were designed with a similar regard for the economic aspects and for the need for standardization. This equipment thus satisfies a great variety of experimental needs; it is readily adaptable and the consumptions of helium and liquid nitrogen are very low. (authors) [French] De nombreuses experiences utilisant les basses temperatures, necessitent l'emploi d'un materiel cryogenique complexe n'existant pas dans le commerce. Les cryostats presentes ici ont ete realises a partir d'elements standard, ce qui permet, malgre la diversite des appareils, de realiser un ensemble a moindre frais. Les reservoirs d'azote et d'helium liquides ont ete concus de facon a limiter les pertes et a conferer au cryostat la plus grande autonomie possible. L'enceinte experimentale situee en general dans la partie inferieure de l'appareil necessite dans tous les cas une etude speciale. D'autre part des ensembles complets tels que les cannes de transfert, piege isole, robinet pour vide secondaire, ont ete concus dans le meme souci de rentabilite et de standardisation. Ce materiel peut donc repondre a un grand nombre d'exigences experimentales, il est facilement adaptable, et les consommations d'helium et d'azote liquide sont tres reduites. (auteurs)

  12. "Nudge" and the epidemic of missed appointments.

    Science.gov (United States)

    Aggarwal, Ajay; Davies, Joanna; Sullivan, Richard

    2016-06-20

    Purpose - Missed appointments constitute a significant problem in the UK National Health Service (NHS) and this remains an area where improvements could yield substantial efficiency savings. The purpose of this paper is to suggest that nudge policies based on behavioural theories may help target interventions to improve patient motivation to attend appointments. Design/methodology/approach - The authors propose two policies to reduce missed appointments. The first attempts to empower patients through making the appointment system more individualised to them and utilising their intrinsic feelings of social responsibility. The second policy utilises a financial commitment given by the patient at the time of booking. The different mechanisms of influencing patient behaviour are based on two different views of what motivates individuals' actions. The first policy is based on individuals being "knights". They are altruistic and have well-intentioned values. The second policy option is constructed on the premise that an individual is governed by self-interest, and they are in fact "knaves". Findings - A policy, which avoids the use of financial penalties is likely to be more culturally acceptable within the NHS. It could also prevent the phenomenon of "crowding out" whereby the desire to act dutifully gets displaced by the motivation to avoid incurring a monetary fine. Originality/value - Testing both strategies would provide insight into patient attitudes towards health care and society. This would help optimise behavioural strategies which may influence not only appointment attendances but also have wider implications for encouraging rational health care consumption.

  13. Missed lung cancer: when, where, and why?

    Science.gov (United States)

    del Ciello, Annemilia; Franchi, Paola; Contegiacomo, Andrea; Cicchetti, Giuseppe; Bonomo, Lorenzo; Larici, Anna Rita

    2017-01-01

    Missed lung cancer is a source of concern among radiologists and an important medicolegal challenge. In 90% of the cases, errors in diagnosis of lung cancer occur on chest radiographs. It may be challenging for radiologists to distinguish a lung lesion from bones, pulmonary vessels, mediastinal structures, and other complex anatomical structures on chest radiographs. Nevertheless, lung cancer can also be overlooked on computed tomography (CT) scans, regardless of the context, either if a clinical or radiologic suspect exists or for other reasons. Awareness of the possible causes of overlooking a pulmonary lesion can give radiologists a chance to reduce the occurrence of this eventuality. Various factors contribute to a misdiagnosis of lung cancer on chest radiographs and on CT, often very similar in nature to each other. Observer error is the most significant one and comprises scanning error, recognition error, decision-making error, and satisfaction of search. Tumor characteristics such as lesion size, conspicuity, and location are also crucial in this context. Even technical aspects can contribute to the probability of skipping lung cancer, including image quality and patient positioning and movement. Albeit it is hard to remove missed lung cancer completely, strategies to reduce observer error and methods to improve technique and automated detection may be valuable in reducing its likelihood. PMID:28206951

  14. Tidal Dwarf Galaxies and Missing Baryons

    Directory of Open Access Journals (Sweden)

    Frederic Bournaud

    2010-01-01

    Full Text Available Tidal dwarf galaxies form during the interaction, collision, or merger of massive spiral galaxies. They can resemble “normal” dwarf galaxies in terms of mass, size, and become dwarf satellites orbiting around their massive progenitor. They nevertheless keep some signatures from their origin, making them interesting targets for cosmological studies. In particular, they should be free from dark matter from a spheroidal halo. Flat rotation curves and high dynamical masses may then indicate the presence of an unseen component, and constrain the properties of the “missing baryons,” known to exist but not directly observed. The number of dwarf galaxies in the Universe is another cosmological problem for which it is important to ascertain if tidal dwarf galaxies formed frequently at high redshift, when the merger rate was high, and many of them survived until today. In this paper, “dark matter” is used to refer to the nonbaryonic matter, mostly located in large dark halos, that is, CDM in the standard paradigm, and “missing baryons” or “dark baryons” is used to refer to the baryons known to exist but hardly observed at redshift zero, and are a baryonic dark component that is additional to “dark matter”.

  15. Missing baryonic resonances in the Hagedorn spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Man Lo, Pok [University of Wroclaw, Institute of Theoretical Physics, Wroclaw (Poland); GSI, Extreme Matter Institute EMMI, Darmstadt (Germany); Marczenko, Michal; Sasaki, Chihiro [University of Wroclaw, Institute of Theoretical Physics, Wroclaw (Poland); Redlich, Krzysztof [University of Wroclaw, Institute of Theoretical Physics, Wroclaw (Poland); GSI, Extreme Matter Institute EMMI, Darmstadt (Germany); Duke University, Department of Physics, Durham, NC (United States)

    2016-08-15

    The hadronic medium of QCD is modeled as a gas of point-like hadrons, with its composition determined by the Hagedorn mass spectrum. The spectrum consists of a discrete and a continuous part. The former is determined by the experimentally confirmed resonances tabulated by the Particle Data Group (PDG), while the latter can be extracted from the existing lattice data. This formulation of the hadron resonance gas (HRG) provides a transparent framework to relate the fluctuation of conserved charges as calculated in the lattice QCD approach to the particle content of the medium. A comparison of the two approaches shows that the equation of state is well described by the standard HRG model, which includes only a discrete spectrum of known hadrons. The corresponding description in the strange sector, however, shows clear discrepancies, thus a continuous spectrum is added to incorporate the effect of missing resonances. We propose a method to extract the strange-baryon spectrum from the lattice data. The result is consistent with the trend set by the unconfirmed strange baryons resonances listed by the PDG, suggesting that most of the missing interaction strength for the strange baryons reside in the S = 1 sector. This scenario is also supported by recent lattice calculations, and might be important in the energy region covered by the NICA accelerator in Dubna, where in the heavy-ion collisions, baryons are the dominating degrees of freedom in the final state. (orig.)

  16. Missed pills: frequency, reasons, consequences and solutions.

    Science.gov (United States)

    Chabbert-Buffet, Nathalie; Jamin, Christian; Lete, Iñaki; Lobo, Paloma; Nappi, Rossella E; Pintiaux, Axelle; Häusler, Günther; Fiala, Christian

    2017-06-01

    Oral hormonal contraception is an effective contraceptive method as long as regular daily intake is maintained. However, a daily routine is a constraint for many women and can lead to missed pills, pill discontinuation and/or unintended pregnancy. This article describes the frequency of inconsistent use, the consequences, the risk factors and the possible solutions. The article comprises a narrative review of the literature. Forgetting one to three pills per cycle is a frequent problem among 15-51% of users, generally adolescents. The reasons for this are age, inability to establish a routine, pill unavailability, side effects, loss of motivation and lack of involvement in the initial decision to use oral contraceptives. The consequences are 'escape ovulations' and, possibly, unintended pregnancy. Solutions are either to use a long-acting method or, for women who prefer to take oral contraceptives, use a continuous or long-cycle regimen to reduce the risks of follicular development and thus the likelihood of ovulation and unintended pregnancy. A progestogen with a long half-life can increase ovarian suppression. For women deciding to use oral contraceptives, a shortened or eliminated hormone-free interval and a progestogen with a long half-life may be an option to reduce the negative consequences of missed oral contraceptive pills.

  17. Investigator's Guide to Missing Child Cases. For Law-Enforcement Officers Locating Missing Children. Second Edition.

    Science.gov (United States)

    Patterson, John C.

    This booklet provides guidance to law enforcement officers investigating missing children cases, whether through parental kidnappings, abductions by strangers, runaway or "throwaway" cases, and those in which the circumstances are unknown. The guide describes, step-by-step, the investigative process required for each of the four types of missing…

  18. 29 CFR 1926.952 - Mechanical equipment.

    Science.gov (United States)

    2010-07-01

    ... equipment that are not covered with insulating protective equipment. (c) Derrick trucks, cranes and other lifting equipment. (1) All derrick trucks, cranes and other lifting equipment shall comply with subpart N...

  19. 22 CFR 135.32 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  20. 21 CFR 1403.32 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  1. 45 CFR 602.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  2. 49 CFR 18.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  3. 34 CFR 80.32 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  4. 10 CFR 600.232 - Equipment.

    Science.gov (United States)

    2010-01-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  5. 45 CFR 1183.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  6. What's missing in missing data? Omissions in survey responses among parents of children with advanced cancer.

    Science.gov (United States)

    Rosenberg, Abby R; Dussel, Veronica; Orellana, Liliana; Kang, Tammy; Geyer, J Russel; Feudtner, Chris; Wolfe, Joanne

    2014-08-01

    Missing data is a common phenomenon with survey-based research; patterns of missing data may elucidate why participants decline to answer certain questions. To describe patterns of missing data in the Pediatric Quality of Life and Evaluation of Symptoms Technology (PediQUEST) study, and highlight challenges in asking sensitive research questions. Cross-sectional, survey-based study embedded within a randomized controlled trial. Three large children's hospitals: Dana-Farber/Boston Children's Cancer and Blood Disorders Center (DF/BCCDC); Children's Hospital of Philadelphia (CHOP); and Seattle Children's Hospital (SCH). At the time of their child's enrollment, parents completed the Survey about Caring for Children with Cancer (SCCC), including demographics, perceptions of prognosis, treatment goals, quality of life, and psychological distress. Eighty-six of 104 parents completed surveys (83% response). The proportion of missing data varied by question type. While 14 parents (16%) left demographic fields blank, over half (n=48; 56%) declined to answer at least one question about their child's prognosis, especially life expectancy. The presence of missing data was unrelated to the child's diagnosis, time from progression, time to death, or parent distress (p>0.3 for each). Written explanations in survey margins suggested that addressing a child's life expectancy is particularly challenging for parents. Parents of children with cancer commonly refrain from answering questions about their child's prognosis, however, they may be more likely to address general cure likelihood than explicit life expectancy. Understanding acceptability of sensitive questions in survey-based research will foster higher quality palliative care research.

  7. Food Service Equipment and Appurtenances.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI.

    Equipment design specifications are presented relating to tables of all kinds, counters, sinks and drainboards, bins, shelves, drawers, hoods and similar kitchen appurtenances, not including baking, roasting, toasting, broiling or frying equipment, food preparation machinery such as slicers, choppers, and cutters, mixers and grinders, steam…

  8. Increasing energy efficiency of a gasoline direct injection engine through optimal synchronization of single or double injection strategies

    International Nuclear Information System (INIS)

    Costa, Michela; Sorge, Ugo; Allocca, Luigi

    2012-01-01

    Highlights: ► Advantages of split injection in a GDI engine are studied through numerical simulation. ► At high load and speed, rich conditions, split injection does not improve engine performance. ► At moderate load and speed, lean conditions, double injection improves charge stratification. ► Optimal double injection increases work, reduces HC and increases NO. - Abstract: The greatest fuel efficiency advantages of gasoline direct injection (GDI) engines are achieved under the so-called mixed mode boosting, where mixture characteristics are properly adapted to the specific working condition. In particular, in the medium range of load and speed, overall lean mixtures are suitable of being used in the so-called direct injection stratified charge operation. Present paper reports the results of numerical optimization analyses aimed at increasing the energetic efficiency of a GDI engine equipped with a high pressure multi-hole injector under both single and double injection events. In moderate-load moderate-speed lean conditions, the single or double injection synchronization in the working cycle is effected through a procedure that couples a 3D numerical model of the in-cylinder processes with an optimization tool. The choice of both the start of the injection events and the time of spark advance is realized to maximize the engine work. The optimal double injection solution is shown to increase the engine energy efficiency with respect to the case injection is realized in one shot, thus confirming that split injections improve the quality of the charge stratification under lean operation. The effect on the major pollutants is also discussed.

  9. Oxygen injection facility

    International Nuclear Information System (INIS)

    Ota, Masamoto; Hirose, Yuki

    1998-01-01

    A compressor introduces air as a starting material and sends it to a dust removing device, a dehumidifying device and an adsorption/separation system disposed downstream. The facility of the present invention is disposed in the vicinity of an injection point and installed in a turbine building of a BWR type reactor having a pipeline of a feedwater system to be injected. The adsorbing/separation system comprises an adsorbing vessel and an automatic valve, and the adsorbing vessel is filled with an adsorbent for selectively adsorbing nitrogen. Zeolite is used as the adsorbent. Nitrogen in the air passing through the adsorbing vessel is adsorbed and removed under a pressurized condition, and a highly concentrated oxygen gas is formed. The direction of the steam of the adsorbed nitrogen is changed by an opening/closing switching operation of an automatic valve and released to the atmosphere (the pressure is released). Generated oxygen gas is stored under pressure in a tank, and injected to the pipeline of the feedwater system by an oxygen injection conduit by way of a flow rate control valve. In the adsorbing vessel, steps of adsorption, separation and storage under pressure are repeated successively. (I.N.)

  10. Water injection dredging

    NARCIS (Netherlands)

    Verhagen, H.J.

    2000-01-01

    Some twenty years ago WIS-dredging has been developed in the Netherlands. By injecting water into the mud layer, the water content of the mud becomes higher, it becomes fluid mud and will start to flow. The advantages of this system are that there is no need of transporting the mud in a hopper, and

  11. Botulinum Neurotoxin Injections

    Science.gov (United States)

    ... botulinum neurotoxin as much art as it is science. It is in your best interest to locate the most well-trained and experienced doctor you can find. Before making an appointment to receive botulinum neuro toxin injections, ask the office personnel which doctor ...

  12. Piperacillin and Tazobactam Injection

    Science.gov (United States)

    ... is in a class of medications called penicillin antibiotics. It works by killing bacteria that cause infection. Tazobactam is ... It works by preventing bacteria from destroying piperacillin.Antibiotics ... injection will not work for colds, flu, or other viral infections. Taking ...

  13. Meropenem and Vaborbactam Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria. Vaborbactam is in a class ... It works by preventing bacteria from destroying meropenem.Antibiotics such as meropenem and vaborbactam injection will not work for colds, flu, or other viral infections. Taking ...

  14. Cold water injection nozzles

    International Nuclear Information System (INIS)

    Kura, Masaaki; Maeda, Masamitsu; Endo, Takio.

    1979-01-01

    Purpose: To inject cold water in a reactor without applying heat cycles to a reactor container and to the inner wall of a feedwater nozzle by securing a perforated plate at the outlet of the cold water injection nozzle. Constitution: A disc-like cap is secured to the final end of a return nozzle of a control rod drive. The cap prevents the flow of a high temperature water flowing downward in the reactor from entering into the nozzle. The cap is perforated with a plurality of bore holes for injecting cold water into the reactor. The cap is made to about 100 mm in thickness so that the cold water passing through the bore holes is heated by the heat conduction in the cap. Accordingly, the flow of high temperature water flowing downwardly in the reactor is inhibited by the cap from backward flowing into the nozzle. Moreover, the flow of the cold water in the nozzle is controlled and rectified when passed through the bore holes in the cap and then injected into the reactor. (Yoshino, Y.)

  15. Pellet injection in WVIIA

    International Nuclear Information System (INIS)

    Renner, H.; Wuersohing, E.; Weller, A.; Jaeckel, H.; Hartfuss, H.; Hacker, H.; Ringler, H.; Buechl, K.

    1986-01-01

    The results of pellet injection experiments in the Wendelstein VII A stellarator are presented. The injector was a single shot pneumatic gun using deuterium pellets. Experiments were carried out in both ECRH and NI plasmas. Data is shown for plasma density, energy confinement, penetration depth and pellet ablation. Results are compared to a neutral gas shielding model

  16. Magnetron injection gun scaling

    International Nuclear Information System (INIS)

    Lawson, W.

    1988-01-01

    Existing analytic design equations for magnetron injection guns (MIG's) are approximated to obtain a set of scaling laws. The constraints are chosen to examine the maximum peak power capabilities of MIG's. The scaling laws are compared with exact solutions of the design equations and are supported by MIG simulations

  17. RHIC injection kicker impedance

    International Nuclear Information System (INIS)

    Mane, V.; Peggs, S.; Trbojevic, D.; Zhang, W.

    1995-01-01

    The longitudinal impedance of the RHIC injection kicker is measured using the wire method up to a frequency of 3 GHz. The mismatch between the 50 ohm cable and the wire and pipe system is calibrated using the TRL calibration algorithm. Various methods of reducing the impedance, such as coated ceramic pipe and copper strips are investigated

  18. SPS injection kicker magnet

    CERN Document Server

    1975-01-01

    One of the first-generation SPS injection kicker magnets. Lifting the tank-lid reveals the inner structure. For a more detailed description see 7502072X. See also 7502074X and Annual Report 1975, p.162. To the left: Roland Tröhler; to the right: Giacomo Busetta.

  19. Direct injection of a diesel-butane blend in a heavy duty engine

    NARCIS (Netherlands)

    Leermakers, C.A.J.; van den Berge, B.; Luijten, C.C.M.; Somers, L.M.T.; Jaasma, S.A.M.; Goey, de L.P.H.

    2011-01-01

    LPG (Liquefied Petroleum Gas) has for long been used in passenger cars. Presently, LPG sup-ply systems have also attracted considerable at-tention for heavy duty use. LPG can be applied in these engines combining port fuel injected LPG with a direct injection of diesel. These engines equipped with a

  20. Equipe de trabalho

    Directory of Open Access Journals (Sweden)

    Gabriel Gerber Hornink

    2014-08-01

    Full Text Available   Equipe de Trabalho 2014 1. Equipe editorial Editor-Chefe Bayardo Bapstista Torres, Instituto de Química - USP, Brasil Eduardo Galembeck, Departamento de Bioquímica Instituto de Biologia UNICAMP, Brasil   Editores Gabriel Gerber Hornink, Depto. Bioquímica, Instituto de Ciências Biomédicas, Universidade - Federal de Alfenas - Unifal-MG, Brasil Vera Maria Treis Trindade, Instituto de Ciências Básicas da Saúde, Departamento de Bioquímica, Universidade Federal do Rio Grande do Sul, Brasil   Corpo Editorial Adriana Cassina, Departamento de Bioquímica, Facultad de Medicina, Universidad de la República, Uruguai Angel Herráez, Departamento de Bioquímica y Biología molecular, Universidad de Alcalá de Henares, Madrid, Espanha André Amaral Gonçalves Bianco, Universidade Federal de São Paulo (Unifesp, Brasil Denise Vaz de Macedo, Departamento de Bioquímica, Instituto de Biologia, Universidade Estadual de Campinas - Unicamp, Brasil Eneida de Paula, Departamento de Bioquímica, Instituto de Biologia, Universidade Estadual de Campinas - Unicamp, Brasil Guilherme Andrade Marson, Instituto de Química - USP, Brasil Jose Antonio Martinez Oyanedel, Universidad de Concepción, Chile Josep Maria Fernández Novell, Dept. Bioquímica i Biologia Molecular Universitat de Barcelona, Espanha Leila Maria Beltramini, Instituto de Física de São Carlos, Universidade Estadual de São Paulo - USP, Brasil Manuel João da Costa, Escola de Ciências da Saúde, Universidade do Minho, Portugal Maria Lucia Bianconi, Instituto de Bioquímica Médica Universidade Federal do Rio de Janeiro (UFRJ, Brasil María Noel Alvarez, Departamento de Bioquímica, Facultad de Medicina, Universidad de la República, Uruguai Miguel Ángel Medina Torres, Department of Molecular Biology & Biochemistry Faculty of Sciences University of Málaga, Espanha Nelma Regina Segnini Bossolan, Instituto de Física de São Carlos, Universidade de São Paulo - USP, Brasil Paulo De Avila

  1. The History of Miss Jane Pittman

    Directory of Open Access Journals (Sweden)

    Christopher Mulvey

    2006-05-01

    Full Text Available This paper explores the ways in which Ernest J. Gaines uses fiction in The Autobiography of Miss Jane Pittman to write a history of the African American from 1861 to 1961. The “Introduction” sets the novel going, but its direction has already been given in the unusual dedication to his grandmother, stepfather and aunt “who did not walk a day in her life but who taught me the importance of standing” (Gaines iv. The significance for Gaines is that what happened a hundred years ago is part of his present-day lived life.The nineteenth-century novel was possessed by history, and white nineteenth-century novelists found their great subject in the war of European nations that was fought between 1799 and 1815. But that was not an American war nor was it an African American war. For Gaines, the war that makes the great turning point of a nation and a people is the American Civil War, fought from 1861 to 1865. It resulted in a moment of history after which life would not be the same. However, one of the main points that Gaines makes about that great turning point in history is that everything changed and nothing changed. And his main fictional device to establish that truth is to tell the history of the hundred years since Emancipation as the story of one woman. Her autobiography becomes an ethno-biography.The continuity forwards from 1861 is given through the life of one woman, but Gaines’s uses another device to provide a continuity backwards from 1861. The young man who wants to get Miss Jane Pittman’s story upsets her with his persistence: “What you want know about Miss Jane for?’ Mary said. ‘I teach history,’ I said. ‘I’m sure her life’s story can help me explain things to my students.’ ‘What’s wrong with them books you already got?’ Mary said. ‘Miss Jane is not in them,’ I said” (Gaines v. Ernest J. Gaines wrote at a time when historians finally began to recognize that they could get no true history of the

  2. Information technology equipment cooling method

    Science.gov (United States)

    Schultz, Mark D.

    2015-10-20

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools air utilized by the rack of information technology equipment to cool the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat generated by the rack of information technology equipment.

  3. Radiotracer injections through microfilters

    International Nuclear Information System (INIS)

    Huber, H.; Maschek, G.; Pichler, R.; Giesen, I.; Hatzl-Griesenhofer, M.; Maschek, W.

    2002-01-01

    Full text: Problems with the injection of radiotracers ( 99m Tc-HAMS, 99m Tc-DPD) to infants when administered through polar-filter-protected venous pathways caused us to get a closer look of what happens to a tracer in such a system. We simulated injections of the tracers mainly used at our institution in an in-vitro array and measured full and empty tracer syringes, filters (0.2 μm micropores) and the post-filter receptacle of the radioactivity. We calculated the percentage of filter-trapped activity and of activity in the receptacle. For several tracers we repeated this process with a neutral filter of the same pore size to get a comparison between the behavior in polarized and electrically inert filters. In general injection of a soluble radiotracer through a polar filter system means a dose loss in the filter of about 10 %, up to the tracer molecule size of IgG-antibodies. Suspended tracers, which consist of comparatively large particles, like RES- or pulmonary perfusion markers, are blocked by the filter, as can be foreseen with a particle size of >> 0.2 μm. DMSA and DPD (a biphosphonate), although both being soluble and rather small molecules, were blocked by the polar filter to a high extent, and by the neutral filter to a much lower, almost neglectable degree. The conclusions are: if possible avoid any use of a filter in your tracer injection pathway. Never use a filter with bone scan or DMSA applications. When doing uptake calculations you have to add the filter counts to the empty syringe value in the formula. If you cannot avoid to inject the radiotracer through a filter you have to replace the filter afterwards and treat the used filter as radioactive waste. The polarity of the filter material might severely affect retention of radiotracer in the filter. (author)

  4. Missing transverse energy performance of the CMS detector

    Energy Technology Data Exchange (ETDEWEB)

    Chatrchyan, Serguei [Yerevan Physics Inst. (Armenia); et al.

    2011-09-01

    During 2010 the LHC delivered pp collisions with a centre-of-mass energy of 7 TeV. In this paper, the results of comprehensive studies of missing transverse energy as measured by the CMS detector are presented. The results cover the measurements of the scale and resolution for missing transverse energy, and the effects of multiple pp interactions within the same bunch crossings on the scale and resolution. Anomalous measurements of missing transverse energy are studied, and algorithms for their identification are described. The performances of several reconstruction algorithms for calculating missing transverse energy are compared. An algorithm, called missing-transverse-energy significance, which estimates the compatibility of the reconstructed missing transverse energy with zero, is described, and its performance is demonstrated.

  5. Missing transverse energy performance of the CMS detector

    International Nuclear Information System (INIS)

    2011-01-01

    During 2010 the LHC delivered pp collisions with a centre-of-mass energy of 7 TeV. In this paper, the results of comprehensive studies of missing transverse energy as measured by the CMS detector are presented. The results cover the measurements of the scale and resolution for missing transverse energy, and the effects of multiple pp interactions within the same bunch crossings on the scale and resolution. Anomalous measurements of missing transverse energy are studied, and algorithms for their identification are described. The performance of several reconstruction algorithms for calculating missing transverse energy are compared. An algorithm, called missing-transverse-energy significance, which estimates the compatibility of the reconstructed missing transverse energy with zero, is described, and its performance is demonstrated.

  6. Reducing Competitive Cache Misses in Modern Processor Architectures

    OpenAIRE

    Prisagjanec, Milcho; Mitrevski, Pece

    2017-01-01

    The increasing number of threads inside the cores of a multicore processor, and competitive access to the shared cache memory, become the main reasons for an increased number of competitive cache misses and performance decline. Inevitably, the development of modern processor architectures leads to an increased number of cache misses. In this paper, we make an attempt to implement a technique for decreasing the number of competitive cache misses in the first level of cache memory. This tec...

  7. Impact of teamwork on missed care in four Australian hospitals.

    Science.gov (United States)

    Chapman, Rose; Rahman, Asheq; Courtney, Mary; Chalmers, Cheyne

    2017-01-01

    Investigate effects of teamwork on missed nursing care across a healthcare network in Australia. Missed care is universally used as an indicator of quality nursing care, however, little is known about mitigating effects of teamwork on these events. A descriptive exploratory study. Missed Care and Team Work surveys were completed by 334 nurses. Using Stata software, nursing staff demographic information and components of missed care and teamwork were compared across the healthcare network. Statistical tests were performed to identify predicting factors for missed care. The most commonly reported components of missed care were as follows: ambulation three times per day (43·3%), turning patient every two hours (29%) and mouth care (27·7%). The commonest reasons mentioned for missed care were as follows: inadequate labour resources (range 69·8-52·7%), followed by material resources (range 59·3-33·3%) and communication (range 39·3-27·2%). There were significant differences in missed care scores across units. Using the mean scores in regression correlation matrix, the negative relationship of missed care and teamwork was supported (r = -0·34, p teamwork alone accounted for about 9% of missed nursing care. Similar to previous international research findings, our results showed nursing teamwork significantly impacted on missed nursing care. Teamwork may be a mitigating factor to address missed care and future research is needed. These results may provide administrators, educators and clinicians with information to develop practices and policies to improve patient care internationally. © 2016 John Wiley & Sons Ltd.

  8. Injecting risk behavior among traveling young injection drug users: travel partner and city characteristics.

    Science.gov (United States)

    Montgomery, Martha E; Fatch, Robin S; Evans, Jennifer L; Yu, Michelle; Davidson, Peter J; Page, Kimberly; Hahn, Judith A

    2013-06-01

    Young injection drug users (IDUs), a highly mobile population, engage in high levels of injecting risk behavior, yet little is understood about how such risk behavior may vary by the characteristics of the cities to which they travel, including the existence of a syringe exchange program (SEP), as well as travel partner characteristics. In 2004-2005, we conducted a 6-month prospective study to investigate the risk behavior of 89 young IDUs as they traveled, with detailed information gathered about 350 city visits. In multivariable analyses, travel to larger urban cities with a population of 500,000-1,000,000 was significantly associated with injecting drugs (adjusted odds ratio (AOR) = 3.71; 95 % confidence interval (CI), 1.56-8.82), ancillary equipment sharing (AES; AOR = 7.05; 95 % CI, 2.25-22.06) and receptive needle sharing (RNS; AOR = 5.73; 95 % CI, 1.11-27.95), as compared with visits to smaller cities with populations below 50,000. Region of the country, and the existence of a SEP within the city visited, were not independently associated with injecting drugs, AES, or RNS during city visits. Traveling with more than one injecting partner was associated with injecting drugs during city visits (AOR = 2.77; 95 % CI, 1.46-5.27), when compared with traveling alone. Additionally, both non-daily and daily/almost daily alcohol use during city visits were associated with AES (AOR = 3.37; 95 % CI, 1.42-7.68; AOR = 3.03; 95 % CI, 1.32-6.97, respectively) as compared with no alcohol consumption. Traveling young IDUs are more likely to inject when traveling with other IDUs and to engage in higher risk injection behavior when they are in large cities. Risk behavior occurring in city visits, including equipment sharing and alcohol consumption, suggests further need for focused interventions to reduce risk for viral infection among this population.

  9. Patient compliance with extended low molecular weight heparin injections following hip and knee arthroplasty.

    Science.gov (United States)

    Deakin, Dan E; Mishreki, Andrew; Aslam, Nadim; Docker, Charles

    2010-01-01

    The use of extended duration thromboprophylaxis following hip and knee arthroplasty is becoming widespread. The aim of our study was to determine patient compliance with extended duration thromboprophylaxis using low molecular weight (LMWH) injections following hip and knee arthroplasty. 42 consecutive patients undergoing hip and knee arthroplasty were prospectively contacted during their fifth post operative week. A fully anonymised questionnaire was completed by each patient. All patients responded. One was excluded having been prescribed warfarin for pre existing atrial fibrillation. Twenty nine (71%) patients were discharged with the intention of self administering LMWH injections. Eight (20%) and four (9%) patients were discharged with the intention of administration by a relative or district nurse respectively. No patient required the person administering the injections to be changed after discharge from hospital. 90% (n=37) of patients reported not missing any doses. 10% (n=2) of patients missed one dose and 10% (n=2) missed two doses. Patient compliance with extended duration thromboprophylaxis using LMWH injections is extremely high. Oral thromboprophylaxis may be useful in the minority of patients requiring daily visits by a nurse to administer injections.

  10. iPod The Missing Manual

    CERN Document Server

    Biersdorfer, J D

    2010-01-01

    With iPod and iTunes, Apple's gotten the world hooked on portable music, pictures, and videos. One thing they haven't delivered, though, is an easy guide for getting the most from your sleek little entertainment center. Enter iPod: The Missing Manual, 5th Edition-a book as breathtaking and satisfying as its subject. Our latest edition thoroughly covers the redesigned iPod Nanos, the video iPod, the tiny Shuffle and the overhauled iTunes 7. Each custom-designed page sports easy-to-follow color graphics, crystal-clear explanations, and guidance on the most useful things your iPod can do. Topic

  11. Bladder injuries frequently missed in polytrauma patients

    Directory of Open Access Journals (Sweden)

    Tanweer Karim

    2010-05-01

    Full Text Available Tanweer Karim, Margaret Topno, Vinod Sharma, Raymond Picardo, Ankur HastirSurgery, MGM Medical College, Kamothe, Navi Mumbai, IndiaAbstract: Bladder injuries are very common in patients who have had road traffic accidents. The method of diagnosis and management of such injuries is well established and accepted. However, trauma to the bladder can be associated with other life-threatening injuries which are frequently missed, and often diagnosed during laparotomy for other reasons. The aim of this study was to diagnose bladder injury in polytrauma patients as early as possible, taking into consideration the fact that these patients are hemodynamically unstable and require rapid evaluation and management. In order to achieve our objective, we used bedside sonography with retrograde instillation of normal saline to diagnose bladder injury in addition to use of the conventional retrograde cystogram.Keywords: bladder injury, bladder rupture, retrograde cystogram

  12. iPad The Missing Manual

    CERN Document Server

    Biersdorfer, J

    2010-01-01

    The iPad 2 is faster, lighter, and more versatile than its predecessor, but there's still no printed guide to using its amazing features. That's where this full-color Missing Manual comes in. Learn how to stream HD video, make video calls, manage your email, surf the Web, listen to music, play games, and maybe even do a little iWork. This is the book that should have been in the box. Build your media library. Fill your iPad with music, movies, TV shows, eBooks, photos, and more.Share with others. Stream music, HD movies, TV shows, and more, to and from your iPad.Create your own media. Use the

  13. iPad 2 The Missing Manual

    CERN Document Server

    Biersdorfer, JD

    2011-01-01

    With iOS 5, Apple added more than 200 new features to the iPad 2, but there's still no printed guide to using all its amazing capabilities. That's where this full-color Missing Manual comes in. You'll learn how to stuff your iPad with media, organize your personal life, wirelessly stream content to and from your tablet, stay connected to friends, and much more. The important stuff you need to know: Build your media library. Fill your iPad with music, movies, TV shows, eBooks, eMagazines, photos, and more.Go wireless. Sync content between your computer and iPad-no wires needed.Get online. Con

  14. Missing IUD Despite Threads at the Cervix

    Directory of Open Access Journals (Sweden)

    Andrew L. Atkinson

    2014-01-01

    Full Text Available Today, the intrauterine device (IUD is by far the most popular form of long term reversible contraception in the world. Side effects from the IUD are minimal and complications are rare. Uterine perforation and migration of the IUD outside the uterine cavity are the most serious complications. Physician visualization and/or the patient feeling retrieval threads at the cervical os are confirmation that the IUD has not been expelled or migrated. We present a case of a perforated, intraperitoneal IUD with threads noted at the cervical os. Office removal was not possible using gentle traction on the threads. Multiple imaging and endoscopic modalities were used to try and locate the IUD including pelvic ultrasound, diagnostic hysteroscopy, cystoscopy, and pelvic magnetic resonance imaging (MRI. The studies gave conflicting results on location of the IUD. Ultimately, the missing IUD was removed via laparoscopy.

  15. iPod The Missing Manual

    CERN Document Server

    Biersdorfer, J D

    2011-01-01

    Apple's iPod still has the world hooked on portable music, pictures, videos, movies, and more, but one thing it doesn't have is a manual that helps you can get the most out this amazing device. That's where this book comes in. Get the complete scoop on the latest line of iPods and the latest version of iTunes with the guide that outshines them all-iPod: The Missing Manual. The 10th edition is as useful, satisfying, and reliable as its subject. Teeming with high-quality color graphics, each page helps you accomplish a specific task-everything from managing your media and installing and browsi

  16. The missing mass of the universe

    International Nuclear Information System (INIS)

    Lachieze-Rey, M.

    2002-01-01

    The existence of dark matter is suggested by 2 facts: 1) the real mass of matter inside galaxies must be 10 times greater than the observed mass to explain the values of the spinning velocity of galaxies around their centers. Furthermore the value of this velocity does not depend a lot on the distance to the center of the galaxy, this implies that the missing mass is uniformly distributed inside galaxies; 2) According to general relativity, massive celestial bodies produce a curvature of space-time that generates a deviation of light beams. These deviations have been studied and it appears that they require the presence of a far more important quantity of matter than the quantity reduced to visible matter. The missing mass issue arises 3 problems, the first problem comes from the existence of a great part of ordinary (baryonic) matter that is invisible: the global mass of stars represents only 10 % of the total baryonic mass of the universe. This invisible ordinary matter might exist in condensed form in black-hole, giant planets or brown dwarfs roaming the galaxies. The second problem arose when most scientists were convinced of the existence of huge quantity of non-baryonic matter, 10 times more abundant than the baryonic matter. The supersymmetric extension of the standard model allows the existence of particles that might be candidate for carrying this non-baryonic mass. The third problem appeared recently when measurement of the curvature of the space-time has shown that the 3 forms of matter: visible matter, invisible ordinary matter and non-baryonic matter contribute together to only one third of the total energy of the universe. (A.C.)

  17. Injecting drug use in prison: prevalence and implications for needle exchange policy.

    Science.gov (United States)

    Wright, Nat M J; Tompkins, Charlotte N E; Farragher, Tracey M

    2015-01-01

    The purpose of this paper is to explore prison drug injecting prevalence, identify any changes in injecting prevalence and practice during imprisonment and explore views on prison needle exchange. An empirical prospective cohort survey conducted between 2006 and 2008. The study involved a random sample of 267 remand and sentenced prisoners from a large male category B prison in England where no prison needle exchange operates. Questionnaires were administered with prisoners on reception and, where possible, at one, three and six months during their sentence. In total, 64 per cent were injecting until admission into prison. The majority intended to stop injecting in prison (93 per cent), almost a quarter due to the lack of needle exchange (23 per cent). Yet when hypothetically asked if they would continue injecting in prison if needle exchange was freely available, a third of participants (33 per cent) believed that they would. Injecting cessation happened on prison entry and appeared to be maintained during the sentence. Not providing sterile needles may increase risks associated with injecting for prisoners who continue to inject. However, providing such equipment may prolong injecting for other prisoners who currently cease injecting on account of needle exchange programmes (NEPs) not being provided in the UK prison setting. Practical implications - Not providing sterile needles may increase risks associated with injecting for prisoners who continue to inject. However, providing such equipment may prolong injecting for other prisoners who currently cease injecting on account of NEPs not being provided in the UK prison setting. This survey is the first to question specifically regarding the timing of injecting cessation amongst male prisoners and explore alongside intention to inject should needle exchange facilities be provided in prison.

  18. Missed Opportunities For Immunization In Children And Pregnant Women

    Directory of Open Access Journals (Sweden)

    Benjamin A I

    1990-01-01

    Full Text Available The role of immunization in reducing childhood mortality cannot be over-emphasised, yet many opportunities for immunization are missed when children and pregnant women visit a health facility. Reducing missed opportunities is the cheapest way to increase immunization coverage. The present study discusses the extent of the problem of missed opportunities for immunization in children and pregnant women and the factors contributing to the problem, in spatiality and community outreach clinics of Christian Medical College & Hospital, Ludhiana. Recommendations are made regarding ways and means of reducing missed opportunities.

  19. Social perspective: the missing element in mental health practice

    National Research Council Canada - National Science Library

    U'Ren, Richard C

    2011-01-01

    .... ________________________________________________________________ Library and Archives Canada Cataloguing in Publication U'Ren, Richard, 1939- Social perspective : the missing element in mental health practice / Richard U'Ren...

  20. Development of manufacturing equipment and QC equipment for DUPIC fuel

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Park, J.J.; Lee, J.W.; Kim, S.S.; Yim, S.P.; Kim, J.H.; Kim, K.H.; Na, S.H.; Kim, W.K.; Shin, J.M.; Lee, D.Y.; Cho, K.H.; Lee, Y.S.; Sohn, J.S.; Kim, M.J.

    1999-05-01

    In this study, DUPIC powder and pellet fabrication equipment, welding system, QC equipment, and fission gas treatment are developed to fabricate DUPIC fuel at IMEF M6 hot cell. The systems are improved to be suitable for remote operation and maintenance with the manipulator at hot cell. Powder and pellet fabrication equipment have been recently developed. The systems are under performance test to check remote operation and maintenance. Welding chamber and jigs are designed and developed to remotely weld DUPIC fuel rod with manipulators at hot cell. Remote quality control equipment are being tested for analysis and inspection of DUPIC fuel characteristics at hot cell. And trapping characteristics is analyzed for cesium and ruthenium released under oxidation/reduction and sintering processes. The design criteria and process flow diagram of fission gas treatment system are prepared incorporating the experimental results. The fission gas treatment system has been successfully manufactured. (Author). 33 refs., 14 tabs., 91 figs

  1. Predictors of injection drug use cessation and relapse in a prospective cohort of young injection drug users in San Francisco, CA (UFO Study).

    Science.gov (United States)

    Evans, Jennifer L; Hahn, Judith A; Lum, Paula J; Stein, Ellen S; Page, Kimberly

    2009-05-01

    Studies of injection drug use cessation have largely sampled adults in drug treatment settings. Little is known about injection cessation and relapse among young injection drug users (IDU) in the community. A total of 365 HCV-negative IDU under age 30 years were recruited by street outreach and interviewed quarterly for a prospective cohort between January 2000 and February 2008. Participants were followed for a total of 638 person-years and 1996 visits. We used survival analysis techniques to identify correlates of injection cessation (> or =3 months) and relapse to injection. 67% of subjects were male, median age was 22 years (interquartile range (IQR) 20-26) and median years injecting was 3.6 (IQR 1.3-6.5). 28.8% ceased injecting during the follow-up period. Among those that ceased injecting, nearly one-half resumed drug injection on subsequent visits, one-quarter maintained injecting cessation, and one-quarter were lost to follow-up. Participating in a drug treatment program in the last 3 months and injecting less than 30 times per month were associated with injection cessation. Injecting heroin or heroin mixed with other drugs, injecting the residue from previously used drug preparation equipment, drinking alcohol, and using benzodiazepines were negatively associated with cessation. Younger age was associated with relapse to injection. These results suggest that factors associated with stopping injecting involve multiple areas of intervention, including access to drug treatment and behavioral approaches to reduce injection and sustain cessation. The higher incidence of relapse in the younger subjects in this cohort underscores the need for earlier detection and treatment programs targeted to adolescents and transition-age youth.

  2. Injection-controlled laser resonator

    Science.gov (United States)

    Chang, J.J.

    1995-07-18

    A new injection-controlled laser resonator incorporates self-filtering and self-imaging characteristics with an efficient injection scheme. A low-divergence laser signal is injected into the resonator, which enables the injection signal to be converted to the desired resonator modes before the main laser pulse starts. This injection technique and resonator design enable the laser cavity to improve the quality of the injection signal through self-filtering before the main laser pulse starts. The self-imaging property of the present resonator reduces the cavity induced diffraction effects and, in turn, improves the laser beam quality. 5 figs.

  3. TRANSPORT AND EMPLACEMENT EQUIPMENT DESCRIPTIONS

    International Nuclear Information System (INIS)

    1997-01-01

    The objective and the scope of this document are to list and briefly describe the major mobile equipment necessary for waste package (WP) Transport and Emplacement in the proposed subsurface nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the equipment are explained and summarized in the individual subsections of this document. The Transport and Emplacement equipment described in this document consists of the following: (1) WP Transporter; (2) Reusable Rail Car; (3) Emplacement Gantry; (4) Gantry Carrier; and (5) Transport Locomotive

  4. Containment and Surveillance Equipment Compendium

    International Nuclear Information System (INIS)

    Luetters, F.O.

    1980-02-01

    The Containment and Surveillance Equipment Compendium contains information sections describing the application and status of seals, optical surveillance systems, and monitors for international safeguards systems. The Compendium is a collection of information on equipment in use (generally by the IAEA) or under development in the US in diverse programs being conducted at numerous facilities under different sponsors. The Compendium establishes a baseline for the status and applications of C/S equipment and is a tool to assist in the planning of future C/S hardware development activities. The Appendix contains design concepts which can be developed to meet future goals

  5. Gaseous poison injection device

    International Nuclear Information System (INIS)

    Kubota, Ryuji; Sugisaki, Toshihiko; Inada, Ikuo.

    1983-01-01

    Purpose: To rapidly control the chain reaction due to thermal neutrons in a reactor core by using gaseous poisons as back-up means for control rod drives. Constitution: Gaseous poisons having a large neutron absorption cross section are used as back-up means for control rod drives. Upon failure of control rod insertion, the gaseous poisons are injected into the lower portion of the reactor core to control the reactor power. As the gaseous poisons, vapors at a high temperature and a higher pressure than that of the coolants in the reactor core are injected to control the reactor power due to the void effects. Since the gaseous poisons thus employed rapidly reach the reactor core and form gas bubbles therein, the deccelerating effect of the thermal neutrons is decreased to reduce the chain reaction. (Moriyama, K.)

  6. SPEAR 3 INJECTION KICKER

    International Nuclear Information System (INIS)

    2002-01-01

    The design of the SPEAR 3 injection kicker system is presented. This system will include three kicker magnets and their associated pulsers. The magnet design is based on the DELTA kicker magnets, which present a low RF impedance to the beam, and are relatively straight-forward to construct. The pulsers use cascaded IGBT stages that are based on the modulator pulsers developed by a SLAC/LLNL collaboration for the NLC. Design considerations and the results of prototype tests will be discussed

  7. Gallium arsenide injection lasers

    International Nuclear Information System (INIS)

    Thompson, G.H.B.

    1975-01-01

    The semiconductor injection laser includes a thin inner GaAs p-n junction layer between two outer GaAlAs layers which are backed by further thin outer GaAlAs layers with a heavier doping of AlAs. This reduces optical losses. Optical energy is further confined within the inner layers and the lasing threshold reduced by added outer GaAs layers of low electrical and thermal resistivity

  8. [Missed lessons, missed opportunities: a role for public health services in medical absenteeism in young people].

    Science.gov (United States)

    Vanneste, Y T M; van de Goor, L A M; Feron, F J M

    2016-01-01

    Young people who often miss school for health reasons are not only missing education, but also the daily routine of school, and social intercourse with their classmates. Medical absenteeism among students merits greater attention. For a number of years, in various regions in the Netherlands, students with extensive medical absenteeism have been invited to see a youth healthcare specialist. The MASS intervention (Medical Advice of Students reported Sick; in Dutch: Medische Advisering van de Ziekgemelde Leerling, abbreviated as M@ZL) has been developed by the West Brabant Regional Public Health Service together with secondary schools to address school absenteeism due to reporting sick. In this paper we discuss the MASS intervention and explain why attention should be paid by public health services to the problem of school absenteeism, especially absenteeism on health grounds.

  9. Near misses and unsafe conditions reported in a Pediatric Emergency Research Network

    Science.gov (United States)

    Ruddy, Richard M; Chamberlain, James M; Mahajan, Prashant V; Funai, Tomohiko; O'Connell, Karen J; Blumberg, Stephen; Lichenstein, Richard; Gramse, Heather L; Shaw, Kathy N

    2015-01-01

    Objective Patient safety may be enhanced by using reports from front-line staff of near misses and unsafe conditions to identify latent safety events. We describe paediatric emergency department (ED) near-miss events and unsafe conditions from hospital reporting systems in a 1-year observational study from hospitals participating in the Pediatric Emergency Care Applied Research Network (PECARN). Design This is a secondary analysis of 1 year of incident reports (IRs) from 18 EDs in 2007–2008. Using a prior taxonomy and established method, this analysis is of all reports classified as near-miss (events not reaching the patient) or unsafe condition. Classification included type, severity, contributing factors and personnel involved. In-depth review of 20% of IRs was performed. Results 487 reports (16.8% of eligible IRs) are included. Most common were medication-related, followed by laboratory-related, radiology-related and process-related IRs. Human factors issues were related to 87% and equipment issues to 11%. Human factor issues related to non-compliance with procedures accounted for 66.4%, including 5.95% with no or incorrect ID. Handoff issues were important in 11.5%. Conclusions Medication and process-related issues are important causes of near miss and unsafe conditions in the network. Human factors issues were highly reported and non-compliance with established procedures was very common, and calculation issues, communications (ie, handoffs) and clinical judgment were also important. This work should enable us to help improve systems within the environment of the ED to enhance patient safety in the future. PMID:26338681

  10. Hydrogen pellet injection device

    International Nuclear Information System (INIS)

    Kanno, Masahiro.

    1992-01-01

    In a hydrogen pellet injection device, a nozzle block having a hydrogen gas supply channel is disposed at the inner side of a main cryogenic housing, and an electric resistor is attached to the block. Further, a nozzle block and a hydrogen gas introduction pipe are attached by way of a thermal insulating spacer. Electric current is supplied to the resistor to positively heat the nozzle block and melt remaining solid hydrogen in the hydrogen gas supply channel. Further, the effect of temperature elevation due to the resistor is prevented from reaching the side of the hydrogen gas introduction pipe by the thermal insulation spacer. That is, the temperature of the nozzle block is directly and positively elevated, to melt the solid hydrogen rapidly. Preparation operation from the injection of the hydrogen pellet to the next injection can be completed in a shorter period of time compared with a conventional case thereby enabling to make the test more efficient. Further, only the temperature of the nozzle block is elevated with no effect of temperature elevation due to the resistor to other components by the thermal insulation flange. (N.H.)

  11. STUDY ON MATERNAL MORTALITY AND NEAR MISS CASE

    Directory of Open Access Journals (Sweden)

    Ritanjali Behera

    2017-12-01

    Full Text Available BACKGROUND Maternal mortality traditionally has been the indicator of maternal health. More recently the review of cases of near miss obstetric event is found to be useful to investigate maternal mortality. Cases of near miss are those, where a woman nearly died but survived a complication that occur during pregnancy or child birth. Aim and Objective 1. To analyse near miss cases and maternal deaths. 2. To determine maternal near miss indicator and to analyse the cause and contributing factors for both of them. MATERIALS AND METHODS This prospective observational study conducted in M.K.C.G. medical college, Berhampur from 1st October 2015 to 30th September 2017. All the cases of maternal deaths and near miss cases defined by WHO criteria are taken. Information regarding demographic profile and reproductive parameters are collected and results are analysed using percentage and proportion. RESULTS Out of 17977 deliveries 201 were near miss cases and 116 were maternal deaths. MMR was 681, near miss incidence 1.18, maternal death to near miss ratio was 1:1.73. Hypertensive disorder of pregnancy (37.4% was the leading cause followed by haemorrhage (17.4%. For near miss cases 101 cases fulfilled clinical criteria, 61 laboratory criteria and 131 cases management based criteria. CONCLUSION Hypertensive disorder of pregnancy and haemorrhage are the leading cause of maternal death and for near miss cases most common organ system involved was cardiovascular system. All the near miss cases should be interpreted as opportunities to improve the health care services.

  12. Handling missing values in the MDS-UPDRS.

    Science.gov (United States)

    Goetz, Christopher G; Luo, Sheng; Wang, Lu; Tilley, Barbara C; LaPelle, Nancy R; Stebbins, Glenn T

    2015-10-01

    This study was undertaken to define the number of missing values permissible to render valid total scores for each Movement Disorder Society Unified Parkinson's Disease Rating Scale (MDS-UPDRS) part. To handle missing values, imputation strategies serve as guidelines to reject an incomplete rating or create a surrogate score. We tested a rigorous, scale-specific, data-based approach to handling missing values for the MDS-UPDRS. From two large MDS-UPDRS datasets, we sequentially deleted item scores, either consistently (same items) or randomly (different items) across all subjects. Lin's Concordance Correlation Coefficient (CCC) compared scores calculated without missing values with prorated scores based on sequentially increasing missing values. The maximal number of missing values retaining a CCC greater than 0.95 determined the threshold for rendering a valid prorated score. A second confirmatory sample was selected from the MDS-UPDRS international translation program. To provide valid part scores applicable across all Hoehn and Yahr (H&Y) stages when the same items are consistently missing, one missing item from Part I, one from Part II, three from Part III, but none from Part IV can be allowed. To provide valid part scores applicable across all H&Y stages when random item entries are missing, one missing item from Part I, two from Part II, seven from Part III, but none from Part IV can be allowed. All cutoff values were confirmed in the validation sample. These analyses are useful for constructing valid surrogate part scores for MDS-UPDRS when missing items fall within the identified threshold and give scientific justification for rejecting partially completed ratings that fall below the threshold. © 2015 International Parkinson and Movement Disorder Society.

  13. An interference account of the missing-VP effect

    Directory of Open Access Journals (Sweden)

    Markus eBader

    2015-06-01

    Full Text Available Sentences with doubly center-embedded relative clauses in which a verb phrase (VP is missing are sometimes perceived as grammatical, thus giving rise to an illusion of grammaticality. In this paper, we provide a new account of why missing-VP sentences, which are both complex and ungrammatical, lead to an illusion of grammaticality, the so-called missing-VP effect. We propose that the missing-VP effect in particular, and processing difficulties with multiply center-embedded clauses more generally, are best understood as resulting from interference during cue-based retrieval. When processing a sentence with double center-embedding, a retrieval error due to interference can cause the verb of an embedded clause to be erroneously attached into a higher clause. This can lead to an illusion of grammaticality in the case of missing-VP sentences and to processing complexity in the case of complete sentences with double center-embedding. Evidence for an interference account of the missing-VP effect comes from experiments that have investigated the missing-VP effect in German using a speeded grammaticality judgments procedure. We review this evidence and then present two new experiments that show that the missing VP effect can be found in German also with less restricting procedures. One experiment was a questionnaire study which required grammaticality judgments from participants but without imposing any time constraints. The second experiment used a self-paced reading procedure and did not require any judgments. Both experiments confirm the prior findings of missing-VP effects in German and also show that the missing-VP effect is subject to a primacy effect as known from the memory literature. Based on this evidence, we argue that an account of missing-VP effects in terms of interference during cue-based retrieval is superior to accounts in terms of limited memory resources or in terms of experience with embedded structures.

  14. Data Center Equipment Location and Monitoring System

    DEFF Research Database (Denmark)

    2013-01-01

    Abstract: Data center equipment location systems include hardware and software to provide information on the location, monitoring, and security of servers and other equipment in equipment racks. The systems provide a wired alternative to the wireless RFID tag system by using electronic ID tags...... connected to each piece of equipment, each electronic ID tag connected directly by wires to an equipment rack controller on the equipment rack. The equipment rack controllers link to a central control computer that provides an operator ...

  15. Assessment of the safety of injection practices and injection-related procedures in family health units and centers in Alexandria.

    Science.gov (United States)

    Elhoseeny, Taghareed A; Mourad, Juidan K

    2014-08-01

    The Safe Injection Global Network (SIGN) developed an intervention strategy for reducing overuse of injections and promoting the administration of safe injections. Tool C--Revised is designed to assess the safety of the most common procedures that puncture the skin within health services. The aim of the study was to assess injection safety within the primary healthcare facilities in Alexandria using Tool C--Revised. A total of 45 family health units and centers in Alexandria were selected by proportional allocation from the eight regions of Alexandria. The Tool C--Revised of the WHO was used for observation of the entire facility, injection practices and injection-related procedures, and sterilization practices. Interview of different health providers and immediate supervisor of injections was carried out. Indicators that reflect risk included: deficiency of alcohol-based hand rub for cleansing hands (13.3%), compliance with hand wash before preparing a procedure (56.9% before injection practices, 61.3% before phlebotomy, and 67.6% before lancet puncture), and wearing a new pair of gloves before new procedures (48.6% before injection practices, 9.7% for phlebotomy, 11.8% for lancet puncture, and 80% for both intravenous injections and infusions). Enough disposable equipment in all facilities for at least 2 weeks dependent on the statement of the average numbers of procedures per week was shown. Only 38% of the providers had received training regarding injection safety in the last 2 years and 62.5% had completed their three doses of hepatitis B vaccine. Only 42.2% of staffs who handled healthcare waste had access to heavy gloves. Indicators related to injection and injection-related practices that reflect risk to patients include deficiency of alcohol-based hand rub tools, nonadherence to hand hygiene before preparing an injection, and inadequate adherence to using a clean barrier when opening a glass ampule and use of gloves. Indicators that may reflect risk to

  16. EAS Equipment Authorization Grantee Registrations

    Data.gov (United States)

    Federal Communications Commission — EAS (Equipment Authorization System). Radio Frequency (RF) devices are required to be properly authorized under 47 CFR Part 2 prior to being marketed or imported...

  17. ENERGY STAR Certified Imaging Equipment

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 2.0 ENERGY STAR Program Requirements for Imaging Equipment that are effective as of...

  18. EMR Measurements on NDA Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Macdonell, Alexander Thomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Meierbachtol, Krista Cruse [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Evans, James Walter Jr. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mayo, Douglas R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-10

    Electromagnetic radiation (EMR) emission strength measurements were performed on a suite of passive non-destructive assay (NDA) radiation detection equipment. Data were collected from 9 kHz up to 6 GHz on each of the assembled systems.

  19. Mongolia - Vocational Education - Equipment Upgrades

    Data.gov (United States)

    Millennium Challenge Corporation — Evaluation design The impact evaluation sought to identify the causal impact of exposure to equipment upgrades on subsequent outcomes. Insofar as we were not able to...

  20. Origins of eponymous orthopaedic equipment.

    Science.gov (United States)

    Meals, Clifton; Wang, Jeffrey

    2010-06-01

    Orthopaedists make great use of eponymous equipment, however the origins of these tools are unknown to many users. This history enriches, enlightens, and enhances surgical education, and may inspire modern innovation. We explored the origins of common and eponymous orthopaedic equipment. We selected pieces of equipment named for their inventors and in the broadest use by modern orthopaedists. We do not describe specialized orthopaedic implants and instruments owing to the overwhelming number of these devices. The history of this equipment reflects the coevolution of orthopaedics and battlefield medicine. Additionally, these stories evidence the primacy of elegant design and suggest that innovation is often a process of revision and refinement rather than sudden inspiration. Their history exposes surgical innovators as brilliant, lucky, hardworking, and sometimes odd. These stories amuse, enlighten, and may inspire modern orthopaedists to develop creative solutions of their own. The rich history of the field's eponymous instruments informs an ongoing tradition of innovation in orthopaedics.

  1. Operation monitor for plant equipment

    International Nuclear Information System (INIS)

    Kondo, Tetsufumi; Kanemoto, Shigeru.

    1991-01-01

    In a nuclear power plant, states of each of equipment in the plant are monitored accurately even under such a operation condition that the power is changed. That is, the fundamental idea is based on a model comparison method. A deviation between an output signal upon normal plant state obtained in a forecasting model device and that of the objective equipment in the plant are compared with a predetermined value. The result of the comparison is inputted to an alarm device to alarm the abnormality of the states of the equipment to an operator. The device of the present invention thus constituted can monitor the abnormality of the operation of equipment accurately even under such a condition that a power level fluctuates. As a result, it can remarkably contribute to mitigate operator's monitoring operation under the condition such as during load following operation. (I.S.)

  2. Equipment improvements for performance enhancement

    International Nuclear Information System (INIS)

    Gaestel, P.; Guesnon, H.; Sauze, G.

    1994-01-01

    In order to enhance the reactor availability, several improvements on reactor equipment have been developed: design optimization for stator maintenance replacement in the main alternator; adjustment modification of stator coils in the main alternator for an easier maintenance; improvement of the fuel handling line (pole crane, transfer equipment, loading machine); development of a loose part trapping system in the steam generator secondary circuit. 1 tab

  3. Low level photoneutron detection equipment

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Yuqin; Li Yuansui

    1991-01-01

    A low level photoneutron detection equipment has been developed. The photoneutrons produced by interaction of 226 Ra gamma quanta and deutron (D) target are detected with n-n discrimination detector made up of 3 He proportional counter array. The D-content information in the target can be obtained from the measured photoneutron counts. The equipment developed is mainly used for nondestructive D-content measurement of D-devices

  4. FUSRAP equipment concept development study

    International Nuclear Information System (INIS)

    Hinerman, K.B.; Smith, R.E.

    1981-01-01

    Under DOE contract, Dalton-Dalton-Newport, Inc. is performing an engineering evaluation of three selected FUSRAP sites in an effort to generate equipment concepts to perform remedial action for retrieval, packaging, storing, and transporting contaminated soil and other debris. Along with this engineering evaluation, an analysis of state and Federal regulations was made which had significant impact on the selected equipment and costs for each remedial action concept

  5. Remotely operated replaceable process equipment

    International Nuclear Information System (INIS)

    Westendorf, H.

    1987-01-01

    The coupling process of pneumatic and electrical auxiliary lines of a pneumatic control pressure line in a large cell of the reprocessing plant is carried out, together with the coupling process of the connecting flange of the process equipment. The coupling places of the auxiliary lines, such as control or supply lines, are laid in the flange parts of the flanges to be connected. The pipe flange on the frame side remains flush with the connecting flange of the process equipment. (DG) [de

  6. Partners in qualified equipment supply

    International Nuclear Information System (INIS)

    Rygg, D.E.; O'Hare, G.J.

    1993-01-01

    Industry initiatives have been taken to improve procurement practices and commercial dedication programs, formation of procurement engineering groups, emphasis on product quality, and increased engineering involvement in procurement and maintenance of qualified equipment. This poses new challenges for many licensees in terms of resources, product knowledge, and access to information normally held proprietary by equipment suppliers. Alternative approaches to future licensee/Westinghouse relationships which will allow licensees to adapt to the changing environment are discussed. 2 figs

  7. Penicillin G (Potassium, Sodium) Injection

    Science.gov (United States)

    Penicillin G injection is used to treat and prevent certain infections caused by bacteria. Penicillin G injection is in a class of medications called penicillins. It works by killing bacteria that cause infections. ...

  8. Amphotericin B Lipid Complex Injection

    Science.gov (United States)

    Amphotericin B lipid complex injection is used to treat serious, possibly life-threatening fungal infections in people who did ... respond or are unable to tolerate conventional amphotericin B therapy. Amphotericin B lipid complex injection is in ...

  9. The Hunt for Missing Dwarf Galaxies

    Science.gov (United States)

    Kohler, Susanna

    2015-11-01

    Theories of galaxy formation and evolution predict that there should be significantly more dwarf galaxies than have been observed. Are our theories wrong? Or are dwarf galaxies just difficult to detect? Recent results from a survey of a galaxy cluster 62 million light-years away suggest there may be lots of undiscovered dwarf galaxies hiding throughout the universe!Hiding in FaintnessThe missing dwarf problem has had hints of a resolution with the recent discovery of Ultra-Diffuse Galaxies (UDGs) in the Coma and Virgo galaxy clusters. UDGs have low masses and large radii, resulting in a very low surface brightness that makes them extremely difficult to detect. If many dwarfs are UDGs, this could well explain why weve been missing them!But the Coma and Virgo galaxy clusters are similar in that theyre both very massive. Are there UDGs in other galaxy clusters as well? To answer this question, an international team of scientists is running the Next Generation Fornax Survey (NGFS), a survey searching for faint dwarf galaxies in the central 30 square degrees of the Fornax galaxy cluster.The NGFS uses near-UV and optical observations from the Dark Energy Camera mounted on the 4m Blanco Telescope in Chile. The survey is still underway, but in a recent publication led by Roberto P. Muoz (Institute of Astrophysics at the Pontifical Catholic University of Chile), the team has released an overview of the first results from only the central 3 square degrees of the NGFS field.Surprising DetectionGalaxy radii vs. their absolute i-band magnitudes, for the dwarfs found in NGFS as well as other stellar systems in the nearby universe. The NGFS dwarfs are similar to the ultra-diffuse dwarfs found in the Virgo and Coma clusters, but are several orders of magnitude fainter. [Muoz et al. 2015]In just this small central field, the team has found an astounding 284 low-surface-brightness dwarf galaxy candidates 158 of them previously undetected. At the bright end of this sample are dwarf

  10. 9 CFR 2.128 - Inspection for missing animals.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Inspection for missing animals. 2.128 Section 2.128 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE ANIMAL WELFARE REGULATIONS Miscellaneous § 2.128 Inspection for missing animals. Each dealer...

  11. Why Patients Miss Follow-Up Appointments: A Prospective Control ...

    African Journals Online (AJOL)

    Reasons include: transport (19 responses), ill-health (6) and financial constraints (5). State transport was unavailable to almost twothirds of the responders who cited transport as a problem. Conclusions: The 17% missed appointment rate is largely due to transport constraints. The commonest time for patients to miss ...

  12. 577 Missed opportunities for inununisation in Natal health facilities

    African Journals Online (AJOL)

    Wkly Epidemwl Rec 1984; 59: 117-119. 5. Expanded Programme on Immunization. Missed immunizacion opportunities and acceptability of immunization. Wkly Epidemiol Rec. 1989;64: 181-184. . . 6. Loevinsohn BP. Missed opportunities for immunization during visits for curative care: practical reasons for their occurrence.

  13. 40 CFR 75.37 - Missing data procedures for moisture.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Missing data procedures for moisture... data procedures for moisture. (a) The owner or operator of a unit with a continuous moisture monitoring system shall substitute for missing moisture data using the procedures of this section. (b) Where no...

  14. 40 CFR 98.405 - Procedures for estimating missing data.

    Science.gov (United States)

    2010-07-01

    ... meter malfunctions), a substitute data value for the missing quantity measurement must be used in the... period for any reason, the reporter shall use either its delivering pipeline measurements or the default... § 98.405 Procedures for estimating missing data. (a) Whenever a quality-assured value of the quantity...

  15. Incidence and Correlates of Maternal Near Miss in Southeast Iran

    Directory of Open Access Journals (Sweden)

    Tayebeh Naderi

    2015-01-01

    Full Text Available This prospective study aimed to estimate the incidence and associated factors of severe maternal morbidity in southeast Iran. During a 9-month period in 2013, all women referring to eight hospitals for termination of pregnancy as well as women admitted during 42 days after the termination of pregnancy were enrolled into the study. Maternal near miss conditions were defined based on Say et al.’s recommendations. Five hundred and one cases of maternal near miss and 19,908 live births occurred in the study period, yielding a maternal near miss ratio of 25.2 per 1000 live births. This rate was 7.5 and 105 per 1000 in private and tertiary care settings, respectively. The rate of maternal death in near miss cases was 0.40% with a case:fatality ratio of 250 : 1. The most prevalent causes of near miss were severe preeclampsia (27.3%, ectopic pregnancy (18.4%, and abruptio placentae (16.2%. Higher age, higher education, and being primiparous were associated with a higher risk of near miss. Considering the high rate of maternal near miss in referral hospitals, maternal near miss surveillance system should be set up in these hospitals to identify cases of severe maternal morbidity as soon as possible.

  16. 78 FR 37598 - Missing Participants in Individual Account Plans

    Science.gov (United States)

    2013-06-21

    ... information from the public to assist it in making decisions about implementing a new program to deal with... allocated to such participant's account.'' Before making decisions about implementing a missing participants... PENSION BENEFIT GUARANTY CORPORATION Missing Participants in Individual Account Plans AGENCY...

  17. Handling of incidents, near-misses

    International Nuclear Information System (INIS)

    Renborg, Bo; Jonsson, Klas; Broqvist, Kristoffer; Keski-Seppaelae, Sven

    2006-12-01

    This work has primarily been done as a study of available literature about reporting systems. The following items have also been considered: the participants' experience of safety work in general and reporting systems in particular, as well as correspondence with researchers and organisations that have experience from reporting systems in safety-critical applications. A number of definitions of the English term 'near-miss' have been found in the documentation about safety-critical systems. An important conclusion is that creating a precise definition in itself is not critical. The main objective is to persuade the individuals to report perceived risks as well as actual events or conditions. In this report, we have chosen to use the following definition of what should be reported: A condition or an incident with potential for more serious consequences. The reporting systems that have been evaluated have all data in the same system; they do not divide data into separate systems for incidents or 'near-misses'. The term incident in the literature is not used consistently, especially if both Swedish and English texts are considered. In a large portion of the documentation where the reporting system is mentioned, the focus lies more on analysis than on the problem with the willingness to report. Even when the focus is on reporting it is often dealing with the design of the actual report in order to enable the subsequent treatment of data. In some cases this has led to unnecessary complicated report forms. The cornerstone of a high willingness to report is the creation of a 'no-blame' culture. Based on experience it can be concluded that the question whether a report could lead to personal reprisals is crucial. Even a system that explicitly gives the reporter immunity is still brittle. The bare suspicion (that immunity may vanish) in the mind of the one reporting reduces the willingness to report dramatically. Meaning that the purpose of the analysis of reports must be to

  18. Frequent food insecurity among injection drug users: correlates and concerns

    Directory of Open Access Journals (Sweden)

    Strike Carol

    2012-12-01

    Full Text Available Abstract Background Food insecurity and nutrition are two topics that are under-researched among injection drug users (IDUs. Our study examined the extent and correlates of food insecurity among a sample of IDUs and explored whether there is an association between food insecurity and injection-related HIV risk. Methods A cross-sectional survey was conducted using interviewer-administered questionnaires. Data were collected at a needle exchange program in London, Ontario, Canada between September 2006 and January 2007. Participants included 144 English-speaking IDUs who had injected drugs in the past 30 days. Participants were asked about their socio-demographic characteristics, HIV risk behaviours, food insecurity, and health/social service use. Results In the past 6 months, 54.5% of participants reported that on a daily/weekly basis they did not have enough to eat because of a lack of money, while 22.1% reported this type of food insecurity on a monthly basis. Moreover, 60.4% and 24.3% reported that they did not eat the quality or quantity of food they wanted on a daily/weekly or a monthly basis, respectively. Participants reported re-using someone else’s injection equipment: 21% re-used a needle, 19% re-used water, and 37.3% re-used a cooker. The odds of sharing injection equipment were increased for food insecure individuals. Conclusions Findings show that IDUs have frequent and variable experiences of food insecurity and these experiences are strongly correlated with sharing of injection-related equipment. Such behaviours may increase the likelihood of HIV and HCV transmission in this population. Addressing food-related needs among IDUs is urgently needed.

  19. Missing transverse momentum in ATLAS: current and future performance

    CERN Document Server

    Schramm, S; The ATLAS collaboration

    2014-01-01

    During the Run-I data taking period, ATLAS has developed and refined several approaches for measuring missing transverse momentum in proton-proton collisions. Standard calorimeter-based $\\mathrm{E}_\\mathrm{T}^\\mathrm{miss}$ reconstruction techniques have been improved to obtain new levels of precision, while new track-based $\\mathrm{p}_\\mathrm{T}^\\mathrm{miss}$ methods provide for a way to have a second independent measurement of the momentum lost due to particles which do not leave tracks in the inner detectors. While both procedures are individually useful, preliminary studies have shown that combining information from both techniques leads to an improved understanding of missing transverse momentum. Data taking conditions during Run-I varied extensively, especially with respect to the amount of pileup activity present in each event, which provides unique challenges to calorimeter-based $\\mathrm{E}_\\mathrm{T}^\\mathrm{miss}$. Multiple solutions have been demonstrated, including methods which exploit both cal...

  20. MISSE in the Materials and Processes Technical Information System (MAPTIS )

    Science.gov (United States)

    Burns, DeWitt; Finckenor, Miria; Henrie, Ben

    2013-01-01

    Materials International Space Station Experiment (MISSE) data is now being collected and distributed through the Materials and Processes Technical Information System (MAPTIS) at Marshall Space Flight Center in Huntsville, Alabama. MISSE data has been instrumental in many programs and continues to be an important source of data for the space community. To facilitate great access to the MISSE data the International Space Station (ISS) program office and MAPTIS are working to gather this data into a central location. The MISSE database contains information about materials, samples, and flights along with pictures, pdfs, excel files, word documents, and other files types. Major capabilities of the system are: access control, browsing, searching, reports, and record comparison. The search capabilities will search within any searchable files so even if the desired meta-data has not been associated data can still be retrieved. Other functionality will continue to be added to the MISSE database as the Athena Platform is expanded

  1. 29 CFR 97.32 - Equipment.

    Science.gov (United States)

    2010-07-01

    ...) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be replaced as... equipment (including replacement equipment), whether acquired in whole or in part with grant funds, until... established to ensure the highest possible return. (e) Disposition. When original or replacement equipment...

  2. 44 CFR 13.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ...) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be replaced as... equipment (including replacement equipment), whether acquired in whole or in part with grant funds, until... established to ensure the highest possible return. (e) Disposition. When original or replacement equipment...

  3. 24 CFR 85.32 - Equipment.

    Science.gov (United States)

    2010-04-01

    ...) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be replaced as... equipment (including replacement equipment), whether acquired in whole or in part with grant funds, until... established to ensure the highest possible return. (e) Disposition. When original or replacement equipment...

  4. 41 CFR 105-71.132 - Equipment.

    Science.gov (United States)

    2010-07-01

    .... (4) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be... managing equipment (including replacement equipment), whether acquired in whole or in part with grant funds... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Equipment. 105-71.132...

  5. 43 CFR 12.72 - Equipment.

    Science.gov (United States)

    2010-10-01

    ...) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be replaced as... equipment (including replacement equipment), whether acquired in whole or in part with grant funds, until... established to ensure the highest possible return. (e) Disposition. When original or replacement equipment...

  6. 1968 Listing of Swimming Pool Equipment.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI. Testing Lab.

    An up-to-date listing of swimming pool equipment including--(1) companies authorized to display the National Sanitation Foundation seal of approval, (2) equipment listed as meeting NSF swimming pool equipment standards relating to diatomite type filters, (3) equipment listed as meeting NSF swimming pool equipment standard relating to sand type…

  7. Safeguards techniques and equipment. 2003 ed

    International Nuclear Information System (INIS)

    2003-01-01

    -destructive analysis (NDA) techniques, and compare their findings with the declared figures and the operator's records. The next level of verification has the aim of detecting whether a fraction of a declared amount is missing (partial defect) and may involve the weighing of items and measurements with NDA techniques such as neutron counting or gamma-ray spectrometry. For detecting bias defects, which would arise if small amounts of material were diverted over a protracted length of time, it is necessary to sample some of the items and to apply physical and chemical analysis techniques having the highest possible accuracy, typically less than one per cent. In order to apply these destructive analysis (DA) techniques, the IAEA requires access to laboratories which use such accurate techniques on a routine basis. Containment and surveillance (C/S) techniques, which are complementary to nuclear material accountancy techniques, are applied in order to maintain continuity of the knowledge gained through IAEA verification, by giving assurance that nuclear material follows predetermined routes, that the integrity of its containment remains unimpaired and that the material is accounted for at the correct measurement points. They also lead to savings in the safeguards inspection effort, e.g. by reducing the frequency of accountancy verification. A variety of C/S techniques are used, primarily optical surveillance and sealing. In remote monitoring, the unattended equipment transmits the data off-site. For unattended and remote monitoring, additional criteria must be met, including high reliability and authentication of the data source. Data communication costs have dropped dramatically in recent years. Data security is an important feature of unattended and remote monitoring systems. Environmental sampling, which allows detection of minute traces of nuclear material, was added to the IAEA's verification measures in the early 1990s as a powerful tool for detecting indications of undeclared

  8. Acupuncture Injection Combined with Electrokinetic Injection for Polydimethylsiloxane Microfluidic Devices

    Directory of Open Access Journals (Sweden)

    Ji Won Ha

    2017-01-01

    Full Text Available We recently reported acupuncture sample injection that leads to reproducible injection of nL-scale sample segments into a polydimethylsiloxane (PDMS microchannel for microchip capillary electrophoresis. The advantages of the acupuncture injection in microchip capillary electrophoresis include capability of minimizing sample loss and voltage control hardware and capability of introducing sample plugs into any desired position of a microchannel. However, the challenge in the previous study was to achieve reproducible, pL-scale sample injections into PDMS microchannels. In the present study, we introduce an acupuncture injection technique combined with electrokinetic injection (AICEI technique to inject pL-scale sample segments for microchip capillary electrophoresis. We carried out the capillary zone electrophoresis (CZE separation of FITC and fluorescein, and the mixture of 10 μM FITC and 10 μM fluorescein was separated completely by using the AICEI method.

  9. Maternal Near-Miss: A Multicenter Surveillance in Kathmandu Valley

    Directory of Open Access Journals (Sweden)

    Ashma Rana

    2013-06-01

    Full Text Available Introduction: Multicenter surveillance has been carried out on maternal near-miss in the hospitals with sentinel units. Near-miss is recognized as the predictor of level of care and maternal death. Reducing maternal mortality ratio is one of the challenges to achieve Millennium Development Goal. Objective was to determine the frequency and the nature of near-miss (severe acute maternal morbidity events and analysis of near-miss morbidities among pregnant women. Methods: Prospective surveillance was done for a year in 2012 in nine hospitals in Kathmandu valley. Cases eligible by definition recorded as a census based on WHO near-miss guideline. Similar questionnaire and dummy tables were used to present the result by non-inferential statistics. Results: Out of 157 cases identified with near-miss rate of 3.8, severe complications were PPH (40% and preeclampsia-eclampsia (17%. Blood transfusion (65%, ICU admission (54% and surgery (32% were the common critical intervention. Oxytocin was the main uterotonic used both prophylactically (86% and therapeutically (76%, and 19% arrived health facility after delivery or abortion. MgSO4 was used in all cases of eclampsia. All of the laparotomies were performed within 3 hours of arrival. Near-miss to mortality ratio was 6:1 and MMR 62. Conclusions: Study result yields similar pattern amongst developing countries and same near-miss conditions as the causes of maternal death reported by national statistics. Process indicators qualify the recommended standard of care. The near-miss event can be used as a surrogate marker of maternal death and a window for system level intervention. Keywords: abortion, eclampsia, hemorrhage, near-miss, surveillance

  10. The Mystery of the Missing Antimatter

    CERN Document Server

    Quinn, Helen R

    2008-01-01

    In the first fractions of a second after the Big Bang lingers a question at the heart of our very existence: why does the universe contain matter but almost no antimatter? The laws of physics tell us that equal amounts of matter and antimatter were produced in the early universe--but then, something odd happened. Matter won out over antimatter; had it not, the universe today would be dark and barren. But how and when did this occur? Helen Quinn and Yossi Nir guide readers into the very heart of this mystery--and along the way offer an exhilarating grand tour of cutting-edge physics. They explain both the history of antimatter and recent advances in particle physics and cosmology. And they discuss the enormous, high-precision experiments that particle physicists are undertaking to test the laws of physics at their most fundamental levels--and how their results reveal tantalizing new possibilities for solving this puzzle at the heart of the cosmos. The Mystery of the Missing Antimatter is at once a history of i...

  11. Why is microcalcification missed on mammography?

    International Nuclear Information System (INIS)

    Peters, Gudrun; Jones, Catherine M.; Daniels, Katie

    2013-01-01

    Ductal carcinoma in situ (DCIS) is often only mammographically evident as microcalcification. Although the overall percentage of screening cases with histologically proven DCIS microcalcification is small, the clinical relevance of missing this finding is significant. The current guidelines in Australia for breast screening departments are for double reading of mammograms to reduce both perceptive and interpretative error. This retrospective study identified patients from a state screening program with histologically proven DCIS whose mammograms showed microcalcification. The initial double reader results were documented according to the 5-point grading scale of BreastScreen Tasmania, and discrepancies between readers were noted. Mammographic factors such as breast density, lesion location, morphology, distribution, size and presence on previous imaging were assessed for significant influence on inter-reader discrepancy. Histological evidence of invasion and grade of malignancy were also analysed. Of 65 identified cases, 29 (45%) showed that one of the two readers had not flagged the microcalcification on the report. Analyses revealed no significant difference in reader discrepancy with any of the analysed factors including breast density, size of microcalcification or presence on previous imaging. Twenty-five of 29 (86%) cases of discrepancy were perceptive. Breast screening reading for microcalcification is poorly correlated to mammographic or histological features. The majority of errors were perceptive rather than interpretative. Double reading is advocated as standard practice to reduce perceptive error.

  12. Search for missing baryons through scintillation

    International Nuclear Information System (INIS)

    Habibi, F.

    2011-06-01

    Cool molecular hydrogen H 2 may be the ultimate possible constituent to the Milky-Way missing baryon. We describe a new way to search for such transparent matter in the Galactic disc and halo, through the diffractive and refractive effects on the light of background stars. By simulating the phase delay induced by a turbulent medium, we computed the corresponding illumination pattern on the earth for an extended source and a given passband. We show that in favorable cases, the light of a background star can be subjected to stochastic fluctuations of the order of a few percent at a characteristic time scale of a few minutes. We have searched for scintillation induced by molecular gas in visible dark nebulae as well as by hypothetical halo clumpuscules of cool molecular hydrogen (H 2 -He) during two nights, using the NTT telescope and the IR SOFI detector. Amongst a few thousands of monitored stars, we found one light-curve that is compatible with a strong scintillation effect through a turbulent structure in the B68 nebula. Because no candidate were found toward the SMC (Small Magellan Cloud), we are able to establish upper limits on the contribution of gas clumpuscules to the Galactic halo mass. We show that the short time-scale monitoring of a few 10 6 star*hour in the visible band with a >4 m telescope and a fast readout camera should allow one to interestingly quantify or constrain the contribution of turbulent molecular gas to the Galactic halo. (author)

  13. Paediatrics and psychoanalysis--Miss Anna Freud.

    Science.gov (United States)

    1983-01-01

    Miss Anna Freud died during the winter at the age of 86. She had been a pioneer in the understanding of children through psychoanalysis and a great champion of the rights of children. Her life began in Vienna as the youngest child of Sigmund Freud, and her early work with children was in Austria. In 1938, because of the Nazi régime and even though she was nursing her father during his terminal illness, she had to escape with him to London. Her work with homeless children and with those in residential nurseries in London during the second world war is well known, as is her work on child development and psychopathology in the postwar years. But one less well known aspect of her life that was of immense importance to a few fortunate British paediatricians was the 'paediatric group' that she ran for over a quarter of a century and which Dr Christine Cooper recalled at the memorial meeting in London earlier this year. PMID:6344806

  14. Water injection profiling

    International Nuclear Information System (INIS)

    Arnold, D.M.

    1982-01-01

    A method of neutron-gamma logging is described, in which water, injected in a cased well borehole with peforations, is irradiated with neutrons of 10 MeV or greater, and subsequent gamma radiation is detected by a pair of detectors along the borehole. Counting rates of detectors are analyzed in terms of two gamma ray energy windows. Linear flow velocity of fluid moving downward within the casing is used in conjunction with count rate data to determine volume flow rates of water moving in other directions. Apparatus includes a sonde with a neutron source and appropriate gamma sensors

  15. MKI UFOs at Injection

    CERN Document Server

    Baer, T; Bartmann, W; Bracco, C; Carlier, E; Chanavat, C; Drosdal, L; Garrel, N; Goddard, B; Kain, V; Mertens, V; Uythoven, J; Wenninger, J; Zerlauth, M

    2011-01-01

    During the MD, the production mechanism of UFOs at the injection kicker magnets (MKIs) was studied. This was done by pulsing the MKIs on a gap in the circulating beam, which led to an increased number of UFOs. In total 43 UFO type beam loss patterns at the MKIs were observed during the MD. The MD showed that pulsing the MKIs directly induces UFO type beam loss patterns. From the temporal characteristics of the loss profile, estimations about the dynamics of the UFOs are made.

  16. SQL Injection Defenses

    CERN Document Server

    Nystrom, Martin

    2007-01-01

    This Short Cut introduces you to how SQL injection vulnerabilities work, what makes applications vulnerable, and how to protect them. It helps you find your vulnerabilities with analysis and testing tools and describes simple approaches for fixing them in the most popular web-programming languages. This Short Cut also helps you protect your live applications by describing how to monitor for and block attacks before your data is stolen. Hacking is an increasingly criminal enterprise, and web applications are an attractive path to identity theft. If the applications you build, manage, or guar

  17. Augmented Reality-Guided Lumbar Facet Joint Injections.

    Science.gov (United States)

    Agten, Christoph A; Dennler, Cyrill; Rosskopf, Andrea B; Jaberg, Laurenz; Pfirrmann, Christian W A; Farshad, Mazda

    2018-05-08

    The aim of this study was to assess feasibility and accuracy of augmented reality-guided lumbar facet joint injections. A spine phantom completely embedded in hardened opaque agar with 3 ring markers was built. A 3-dimensional model of the phantom was uploaded to an augmented reality headset (Microsoft HoloLens). Two radiologists independently performed 20 augmented reality-guided and 20 computed tomography (CT)-guided facet joint injections each: for each augmented reality-guided injection, the hologram was manually aligned with the phantom container using the ring markers. The radiologists targeted the virtual facet joint and tried to place the needle tip in the holographic joint space. Computed tomography was performed after each needle placement to document final needle tip position. Time needed from grabbing the needle to final needle placement was measured for each simulated injection. An independent radiologist rated images of all needle placements in a randomized order blinded to modality (augmented reality vs CT) and performer as perfect, acceptable, incorrect, or unsafe. Accuracy and time to place needles were compared between augmented reality-guided and CT-guided facet joint injections. In total, 39/40 (97.5%) of augmented reality-guided needle placements were either perfect or acceptable compared with 40/40 (100%) CT-guided needle placements (P = 0.5). One augmented reality-guided injection missed the facet joint space by 2 mm. No unsafe needle placements occurred. Time to final needle placement was substantially faster with augmented reality guidance (mean 14 ± 6 seconds vs 39 ± 15 seconds, P Augmented reality-guided facet joint injections are feasible and accurate without potentially harmful needle placement in an experimental setting.

  18. Performance monitoring of safeguards equipment

    International Nuclear Information System (INIS)

    Sirisena, K.; Peltoranta, M.; Goussarov, V.; Vodrazka, P.

    1999-01-01

    SGTCS is responsible for monitoring and reporting the performance of the SG equipment. Performance monitoring (PM) has been implemented in most important safeguards equipment operating unattended in nuclear facilities. Inspectors acquire equipment performance data in facilities. After inspection, the data package is submitted to SGTCS for processing and analysis. The performance data is used for identification of systems or components, which should be changed in the field and for identification of modules which, should be diagnosed at HQ in order to determine the cause of failure. Moreover, the performance data is used for preventive maintenance and spares distribution planning, and to provide statistics for official reports and management decision making. An important part of the performance monitoring is reporting. Equipment performance reports contain information about equipment inventory, utilization, failure types, failure distribution, and reliability. Trends in performance are given in graphical form in cases, where past data is available. Reliability estimates such as expected times between failures are provided. The automated reporting tools are obtainable through EMIS database application. (author)

  19. AVM branch vibration test equipment

    International Nuclear Information System (INIS)

    Anne, J.P.

    1995-01-01

    An inventory of the test equipment of the AVM Branch ''Acoustic and Vibratory Mechanics Analysis Methods'' group has been undertaken. The purpose of this inventory is to enable better acquaintance with the technical characteristics of the equipment, providing an accurate definition of their functionalities, ad to inform potential users of the possibilities and equipment available in this field. The report first summarizes the various experimental surveys conduced. Then, using the AVM equipment database to draw up an exhaustive list of available equipment, it provides a full-scope picture of the vibration measurement systems (sensors, conditioners and exciters) and data processing resources commonly used on industrial sites and in laboratories. A definition is also given of a mobile test unit, called 'shelter', and a test bench used for the testing and performance rating of the experimental analysis methods developed by the group. The report concludes with a description of two fixed installations: - the calibration bench ensuring the requisite quality level for the vibration measurement systems ; - the training bench, whereby know-how acquired in the field in the field of measurement and experimental analysis processes is made available to others. (author). 27 refs., 15 figs., 2 appends

  20. 78 FR 25916 - Authorization of Radiofrequency Equipment

    Science.gov (United States)

    2013-05-03

    ...] Authorization of Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Proposed rule... bodies, and measurement procedures used to determine RF equipment compliance. The Commission believes... Commission is responsible for an equipment authorization program for radiofrequency (RF) devices under part 2...

  1. Efficient Spin Injection into Semiconductor

    International Nuclear Information System (INIS)

    Nahid, M.A.I.

    2010-06-01

    Spintronic research has made tremendous progress nowadays for making future devices obtain extra advantages of low power, and faster and higher scalability compared to present electronic devices. A spintronic device is based on the transport of an electron's spin instead of charge. Efficient spin injection is one of the very important requirements for future spintronic devices. However, the effective spin injection is an exceedingly difficult task. In this paper, the importance of spin injection, basics of spin current and the essential requirements of spin injection are illustrated. The experimental technique of electrical spin injection into semiconductor is also discussed based on the experimental experience. The electrical spin injection can easily be implemented for spin injection into any semiconductor. (author)

  2. Risk Factors Associated with Unsafe Injection Practices at the First Injection Episode among Intravenous Drug Users in France: Results from PrimInject, an Internet Survey

    Directory of Open Access Journals (Sweden)

    Anne Guichard

    2015-01-01

    Full Text Available Background. New drug use patterns may increase the risk of human immunodeficiency virus and hepatitis infections. In France, new injection patterns among youths with diverse social backgrounds have emerged, which may explain the persistently high rates of hepatitis C virus infection. This study explores factors associated with injection risk behaviours at first injection among users who began injecting in the post-2000 era. Methods. A cross-sectional study was conducted on the Internet from October 2010 to March 2011, through an online questionnaire. Multivariate logistic regression identified the independent correlates of needle sharing and equipment (cooker/cotton filter sharing. Results. Among the 262 respondents (mean age 25 years, 65% were male. Both risk behaviours were positively associated with initiation before 18 years of age (aOR 3.7 CI 95% 1.3–10.6 and aOR 3.0 CI 95% 1.3–7.0 and being injected by another person (aOR 3.1 CI 95% 1.0–9.9 and aOR 3.0 CI 95% 1.3–7.1. Initiation at a party was an independent correlate of equipment sharing (aOR 2.6 95% CI 1.0–6.8. Conclusions. Results suggest a need for innovative harm reduction programmes targeting a variety of settings and populations, including youths and diverse party scenes. Education of current injectors to protect both themselves and those they might initiate into injection is critically important.

  3. Another donation of computer equipment

    CERN Multimedia

    Anaïs Schaeffer

    2014-01-01

    On Thursday 27 February, CERN was pleased to donate computer equipment to a physics institute in the Philippines.   H.E. Leslie J. Baja and Rolf Heuer. Following donations of computer equipment to institutes in Morocco, Ghana, Bulgaria, Serbia and Egypt, CERN is to send 50 servers and 4 network switches to the National Institute of Physics at the University of the Philippines Diliman. CERN’s Director-General Rolf Heuer and the Ambassador of the Philippines to Switzerland and Lichtenstein, H.E. Leslie J. Baja, spoke of their enthusiasm for the project during an official ceremony. The equipment will be used for various high energy physics research programmes in the Philippines and for the University’s development of digital resources for science.

  4. Reduction of artefacts due to missing projections using OSEM

    International Nuclear Information System (INIS)

    Hutton, B.F.; Kyme, A.; Choong, K.

    2002-01-01

    Full text: It is well recognised that missing or corrupted projections can result in artefacts. This occasionally occurs due to errors in data transfer from acquisition memory to disk. A possible approach for reducing these artefacts was investigated, Using ordered subsets expectation maximization (OSEM) the iterative reconstruction proceeds by progressively including additional projections until a single iteration is complete. Clinically useful results can be obtained using a small subset size in a single iteration. Stopping prior to the complete iteration so as to avoid inclusion of missing or corrupted data should provide a 'partial' reconstruction with minimal artefacts. To test this hypothesis projections were selectively removed from a complete data set (2, 4, 8, 12 adjacent projections) and reconstructions were performed using both filtered back projection (FBP) and OSEM. To maintain a constant number of sub-iterations in OSEM an equal number of duplicate projections were substituted for the missing projections. Both 180 and 360 degrees reconstructions with missing data were compared with reconstruction for the complete data using sum of absolute differences. Results indicate that missing data causes artefacts for both FBP and OSEM however the severity of artefacts is significantly reduced using OSEM. The effect of missing data is generally greater for 180 degrees acquisition. OSEM is recommended for minimising reconstruction artefacts due to missing projections. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  5. Recurrent Neural Networks for Multivariate Time Series with Missing Values.

    Science.gov (United States)

    Che, Zhengping; Purushotham, Sanjay; Cho, Kyunghyun; Sontag, David; Liu, Yan

    2018-04-17

    Multivariate time series data in practical applications, such as health care, geoscience, and biology, are characterized by a variety of missing values. In time series prediction and other related tasks, it has been noted that missing values and their missing patterns are often correlated with the target labels, a.k.a., informative missingness. There is very limited work on exploiting the missing patterns for effective imputation and improving prediction performance. In this paper, we develop novel deep learning models, namely GRU-D, as one of the early attempts. GRU-D is based on Gated Recurrent Unit (GRU), a state-of-the-art recurrent neural network. It takes two representations of missing patterns, i.e., masking and time interval, and effectively incorporates them into a deep model architecture so that it not only captures the long-term temporal dependencies in time series, but also utilizes the missing patterns to achieve better prediction results. Experiments of time series classification tasks on real-world clinical datasets (MIMIC-III, PhysioNet) and synthetic datasets demonstrate that our models achieve state-of-the-art performance and provide useful insights for better understanding and utilization of missing values in time series analysis.

  6. Geochemical modelling: what phenomena are missing

    International Nuclear Information System (INIS)

    Jacquier, P.

    1989-12-01

    In the framework of safety assessment of radioactive waste disposal, retention phenomena are usually taken into account by the Kd concept. It is well recognized that this concept is not enough for safety assessment models, because of the several and strong assumptions which are involved in this kind of representation. One way to have a better representation of the retention phenomena, is to substitute for this Kd concept an explicit description of geochemical phenomena and then couple transport codes with geochemical codes in a fully or a two-step procedure. We use currently such codes, but the scope of this paper is to display the limits today of the geochemical modelling in connection with sites analysis for deep disposal. In this paper, we intend to give an overview of phenomena which are missing in the geochemical models, or which are not completely introduced in the models. We can distinguish, on one hand phenomena for which modelling concepts exist such as adsorption/desorption and, on the other hand, phenomena for which modelling concepts do not exist for the moment such as colloids, and complexation by polyelectrolyte solutions (organics). Moreover we have to take care of very low concentrations of radionuclides, which can be expected from the leaching processes in the repository. Under those conditions, some reactions may not occur. After a critical review of the involved phenomena, we intend to stress the main directions of the wishful evolution of the geochemical modelling. This evolution should improve substantially the quality of the above-mentioned site assessments

  7. China's "missing girls": prospects and policy.

    Science.gov (United States)

    Riley, N E

    1996-02-01

    Women's conditions in China are viewed as deteriorating. The reduction in government control over urban factories and other places of employment has resulted in fewer women being hired. This leaves women in positions with low wages, poor working conditions, and discrimination based on sex, age, and marital status. The shift from rural state-controlled agricultural collectives to patriarchal family controls resulted in land distribution that gave men preference. The rapid growth in the economy and higher standards of living placed women at risk. Although the pressures to kill girl babies have relaxed, there is growing interest in making money from abducting and selling women for prostitution, marriage, and slavery. Women gained in recent decades greater participation in the labor force and higher educational levels. Women's access to health care is better. Female life expectancy is 72 years compared to 69 years for men. Maternal mortality is 95 deaths per 100,000 live births. Yet women hold subordinate positions to men in their jobs, and women are segregated in the textile and service industries. Women in rural areas have primarily access to agricultural jobs, which can be combined with child care. Women are less likely to be promoted and are retired 5 years earlier than men. Women carry a double burden of domestic labor and paid or unpaid labor. Women still have higher illiteracy rates than men, and the gender gap in higher education has remained stable since the 1970s. The imbalanced sex ratio is increasing. In some provinces it is 114 males for every 100 females, when the normal ratio is 105-106 males per 100 females. An estimated 12% of females are unaccounted for each year. The reasons for the missing children are identified as sex-selective abortion, infanticide, or underreporting. The next five-year plan holds the hope for improvement in women's status and an end to abuses against women and children.

  8. The Mysterious Case of the Missing Filaments

    Science.gov (United States)

    Alden, C. R.

    2016-12-01

    Coronal Mass Ejections, or CMEs, are large solar eruptions that can have major debilitating impacts on society. Typically, these eruptions have the three following key structures: the leading edge, the empty chamber known as the cavity, and the filament which often is the brightest part of the CME. When we can see all three structures clearly with a coronagraph, it is called a classic three-part CME, also referred to as a 'lightbulb' CME. According to current knowledge, when a CME erupts, a filament should also erupt or lift off the Sun in order to have the bright center within the CME. However, we do not always see a filament erupt at the surface, and yet we still get a 'filament' within the coronagraph CME. To better understand what might be occurring with these missing filaments, we looked at three-part CMEs using the SOHO LASCO CME Catalog and filaments from the SDO AIA Filament Catalog in order to create a list of 50 CMEs without a listed filament erupting at the surface. For those CMEs without filaments in the list we closely inspected the AIA images for evidence of filament eruption. To ensure that there were no filaments past the limb of the Sun, we used data from the STEREO-A and STEREO-B spacecraft's to look at the Sun from other angles. We have found numerous events where no filament erupts from the surface, but we still see the classic three-part CME. We believe this may be due to an optical illusion occurring from the twisting of the flux rope.

  9. Waste Electrical and Electronic Equipment

    DEFF Research Database (Denmark)

    Bigum, Marianne Kristine Kjærgaard; Christensen, Thomas Højlund

    2011-01-01

    Waste electrical and electronic equipment (WEEE) is one of the fastest growing special waste types with an estimated growth of 3–5% per year (Cui and Forssberg, 2003). WEEE is a very heterogeneous waste type that contains many compounds that are considered to be harmful to both humans and the env......Waste electrical and electronic equipment (WEEE) is one of the fastest growing special waste types with an estimated growth of 3–5% per year (Cui and Forssberg, 2003). WEEE is a very heterogeneous waste type that contains many compounds that are considered to be harmful to both humans...

  10. The development of superconducting equipment

    CERN Document Server

    Ueda, T; Hiue, H

    2003-01-01

    Fuji Electric has been developing various types of superconducting equipment for over a quarter of a century. This paper describes the development results achieved for superconducting equipment and especially focuses on large-capacity current leads and superconducting transmission systems, the development of which is being promoted for application to the field of nuclear fusion. High temperature superconductor (HTS) is becoming the mainstream in the field of superconductivity, and the HTS floating coil and conduction-cooled HTS transformed are also introduced as recent developments for devices that utilize this technology. (author)

  11. Mechanical (turbines and auxiliary equipment)

    CERN Document Server

    Sherry, A; Cruddace, AE

    2013-01-01

    Modern Power Station Practice, Volume 3: Mechanical (Turbines and Auxiliary Equipment) focuses on the development of turbines and auxiliary equipment used in power stations in Great Britain. Topics covered include thermodynamics and steam turbine theory; turbine auxiliary systems such as lubrication systems, feed water heating systems, and the condenser and cooling water plants. Miscellaneous station services, and pipework in power plants are also described. This book is comprised of five chapters and begins with an overview of thermodynamics and steam turbine theory, paying particular attenti

  12. Maternal near-miss: a multicenter surveillance in Kathmandu Valley.

    Science.gov (United States)

    Rana, Ashma; Baral, Gehanath; Dangal, Ganesh

    2013-01-01

    Multicenter surveillance has been carried out on maternal near-miss in the hospitals with sentinel units. Near-miss is recognized as the predictor of level of care and maternal death. Reducing Maternal Mortality Ratio is one of the challenges to achieve Millennium Development Goal. The objective was to determine the frequency and the nature of near-miss events and to analyze the near-miss morbidities among pregnant women. A prospective surveillance was done for a year in 2012 at nine hospitals in Kathmandu valley. Cases eligible by definition were recorded as a census based on WHO near-miss guideline. Similar questionnaires and dummy tables were used to present the results by non-inferential statistics. Out of 157 cases identified with near-miss rate of 3.8 per 1000 live births, severe complications were postpartum hemorrhage 62 (40%) and preeclampsia-eclampsia 25 (17%). Blood transfusion 102 (65%), ICU admission 85 (54%) and surgery 53 (32%) were common critical interventions. Oxytocin was main uterotonic used both prophylactically and therapeutically at health facilities. Total of 30 (19%) cases arrived at health facility after delivery or abortion. MgSO4 was used in all cases of eclampsia. All laparotomies were performed within three hours of arrival. Near-miss to maternal death ratio was 6:1 and MMR was 62. Study result yielded similar pattern amongst developing countries and same near-miss conditions as the causes of maternal death reported by national statistics. Process indicators qualified the recommended standard of care. The near-miss event could be used as a surrogate marker of maternal death and a window for system level intervention.

  13. Missing and Spurious Level Corrections for Nuclear Resonances

    International Nuclear Information System (INIS)

    Mitchell, G E; Agvaanluvsan, U; Pato, M P; Shriner, J F

    2005-01-01

    Neutron and proton resonances provide detailed level density information. However, due to experimental limitations, some levels are missed and some are assigned incorrect quantum numbers. The standard method to correct for missing levels uses the experimental widths and the Porter-Thomas distribution. Analysis of the spacing distribution provides an independent determination of the fraction of missing levels. We have derived a general expression for such an imperfect spacing distribution using the maximum entropy principle and applied it to a variety of nuclear resonance data. The problem of spurious levels has not been extensively addressed

  14. Fear of repeated injections in children younger than 4 years receiving subcutaneous allergy immunotherapy.

    Science.gov (United States)

    de Vos, Gabriele; Shankar, Viswanathan; Nazari, Ramin; Kooragayalu, Shravan; Smith, Mitchell; Wiznia, Andrew; Rosenstreich, David

    2012-12-01

    Allergy immunotherapy during early childhood may have potential benefits for the prevention of asthma and allergy morbidity. However, subcutaneous immunotherapy has not yet been prospectively researched in children younger than 4 years, primarily because of safety concerns, including the fear and psychological distress young children may experience with repeated needle injections. To quantify fear in atopic children younger than 4 years with a history of wheezing who are receiving subcutaneous immunotherapy. Fear of injection was graded during a total of 788 immunotherapy injection visits in 18 children (age, 37 months; SD, 9 months) receiving subcutaneous allergy immunotherapy. The parent and the injection nurse assigned fear scores on a scale of 0 to 10 after each injection visit. At the time of analysis, children had a median of 49 injection visits (range, 12-88) during a median study period of 81.5 weeks (range, 15-165 weeks). Fifteen children (83%) lost their fear of injections during the study. A fear score of 0 was achieved after a mean of 8.4 visits (SD, 7.4). The more injection visits were missed, the more likely children were to retain fear of injections (hazard ratio, 0.13; 95% confidence interval, 0.02-1.02; P=.05). Age, adverse events, number of injections at each visit, and change of injection personnel were not associated with increased fear. Our analysis suggests that most children receiving weekly subcutaneous immunotherapy lose their fear of injections during the treatment course. Children with increased intervals between visits may be at higher risk of experiencing fear of injections. clinicaltrial.gov identifier NCT01028560. Copyright © 2012 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  15. Premixed direct injection nozzle

    Science.gov (United States)

    Zuo, Baifang [Simpsonville, SC; Johnson, Thomas Edward [Greer, SC; Lacy, Benjamin Paul [Greer, SC; Ziminsky, Willy Steve [Simpsonville, SC

    2011-02-15

    An injection nozzle having a main body portion with an outer peripheral wall is disclosed. The nozzle includes a plurality of fuel/air mixing tubes disposed within the main body portion and a fuel flow passage fluidly connected to the plurality of fuel/air mixing tubes. Fuel and air are partially premixed inside the plurality of the tubes. A second body portion, having an outer peripheral wall extending between a first end and an opposite second end, is connected to the main body portion. The partially premixed fuel and air mixture from the first body portion gets further mixed inside the second body portion. The second body portion converges from the first end toward said second end. The second body portion also includes cooling passages that extend along all the walls around the second body to provide thermal damage resistance for occasional flame flash back into the second body.

  16. ErythropoieSIS stimulating agent (ESA use is increased following missed dialysis sessions

    Directory of Open Access Journals (Sweden)

    T. Christopher Bond

    2012-06-01

    Missed session episodes result in significant increases in ESA utilization in the post-miss period, and also in total monthly ESA use. Such increases should be considered in any assessment of impact of missed sessions: both clinical and economic.

  17. Pocket dictionary of laboratory equipment

    International Nuclear Information System (INIS)

    Junge, H.D.

    1987-01-01

    This pocket dictionary contains the 2500 most common terms for scientific and technical equipment in chemical laboratories. It is a useful tool for those who are used to communicating in German and English, but have to learn the special terminology in this field. (orig.) [de

  18. Using Gaming Equipment to Teach

    Science.gov (United States)

    Curriculum Review, 2009

    2009-01-01

    Gaming equipment (such as Nintendo's Wii[TM]) is making its way to schools and classrooms. However, most of the discussion regarding how to use this technology and integrate it into lesson plans is happening in blogs on the Internet. An advocate of interactive media in the classroom, Dr. Dawn Hawkins, a faculty member for the Art Institute of…

  19. Isotope-equipped measuring instruments

    International Nuclear Information System (INIS)

    Miyagawa, Kazuo; Amano, Hiroshi

    1980-01-01

    In the steel industry, though the investment in isotope-equipped measuring instruments is small as compared with that in machinery, they play important role in the moisture measurement in sintering and blast furnaces, the thickness measurement in rolling process and others in automatic control systems. The economic aspect of the isotope-equipped measuring instruments is described on the basis of the practices in Kimitsu Works of Nippon Steel Corporation: distribution of such instruments, evaluation of economic effects, usefulness evaluation in view of raising the accuracy, and usefulness evaluation viewed from the failure of the isotope instruments. The evaluation of economic effects was made under the premise that the isotope-equipped measuring instruments are not employed. Then, the effects of raising the accuracy are evaluated for a γ-ray plate thickness gauge and a neutron moisture gauge for coke in a blast furnace. Finally, the usefulness was evaluated, assuming possible failure of the isotope-equipped measuring instruments. (J.P.N.)

  20. Hydraulic turbines and auxiliary equipment

    Energy Technology Data Exchange (ETDEWEB)

    Luo Gaorong [Organization of the United Nations, Beijing (China). International Centre of Small Hydroelectric Power Plants

    1995-07-01

    This document presents a general overview on hydraulic turbines and auxiliary equipment, emphasizing the turbine classification, in accordance with the different types of turbines, standard turbine series in China, turbine selection based on the basic data required for the preliminary design, general hill model curves, chart of turbine series and the arrangement of application for hydraulic turbines, hydraulic turbine testing, and speed regulating device.

  1. Reducing Misses and Near Misses Related to Multitasking on the Electronic Health Record: Observational Study and Qualitative Analysis.

    Science.gov (United States)

    Ratanawongsa, Neda; Matta, George Y; Bohsali, Fuad B; Chisolm, Margaret S

    2018-02-06

    Clinicians' use of electronic health record (EHR) systems while multitasking may increase the risk of making errors, but silent EHR system use may lower patient satisfaction. Delaying EHR system use until after patient visits may increase clinicians' EHR workload, stress, and burnout. We aimed to describe the perspectives of clinicians, educators, administrators, and researchers about misses and near misses that they felt were related to clinician multitasking while using EHR systems. This observational study was a thematic analysis of perspectives elicited from 63 continuing medical education (CME) participants during 2 workshops and 1 interactive lecture about challenges and strategies for relationship-centered communication during clinician EHR system use. The workshop elicited reflection about memorable times when multitasking EHR use was associated with "misses" (errors that were not caught at the time) or "near misses" (mistakes that were caught before leading to errors). We conducted qualitative analysis using an editing analysis style to identify codes and then select representative themes and quotes. All workshop participants shared stories of misses or near misses in EHR system ordering and documentation or patient-clinician communication, wondering about "misses we don't even know about." Risk factors included the computer's position, EHR system usability, note content and style, information overload, problematic workflows, systems issues, and provider and patient communication behaviors and expectations. Strategies to reduce multitasking EHR system misses included clinician transparency when needing silent EHR system use (eg, for prescribing), narrating EHR system use, patient activation during EHR system use, adapting visit organization and workflow, improving EHR system design, and improving team support and systems. CME participants shared numerous stories of errors and near misses in EHR tasks and communication that they felt related to EHR

  2. LHC Injection Beam Quality During LHC Run I

    CERN Document Server

    AUTHOR|(CDS)2079186; Kain, Verena; Stapnes, Steinar

    The LHC at CERN was designed to accelerate proton beams from 450 GeV to 7 TeV and collide them in four large experiments. The 450 GeV beam is extracted from the last pre-accelerator, the SPS, and injected into the LHC via two 3 km long transfer lines, TI 2 and TI 8. The injection process is critical in terms of preservation of beam quality and machine protection. During LHC Run I (2009-2013) the LHC was filled with twelve high intensity injections per ring, in batches of up to 144 bunches of 1.7*10^11 protons per bunch. The stored beam energy of such a batch is already an order of magnitude above the damage level of accelerator equipment. Strict quality and machine protection requirements at injection have a significant impact on operational efficiency. During the first years of LHC operation, the injection phase was identified as one of the limiting factors for fast LHC turnaround time. The LHC Injection Quality Check (IQC) software framework was developed as a part of this thesis to monitor the beam quality...

  3. Injection device-related risk management toward safe administration of medications: experience in a university teaching hospital in The People's Republic of China.

    Science.gov (United States)

    Zhu, Ling-Ling; Li, Wei; Song, Ping; Zhou, Quan

    2014-01-01

    The use of injection devices to administer intravenous or subcutaneous medications is common practice throughout a variety of health care settings. Studies suggest that one-half of all harmful medication errors originate during drug administration; of those errors, about two-thirds involve injectables. Therefore, injection device management is pivotal to safe administration of medications. In this article, the authors summarize the relevant experiences by retrospective analysis of injection device-related near misses and adverse events in the Second Affiliated Hospital of Zhejiang University, School of Medicine, Zhejiang University, People's Republic of China. Injection device-related near misses and adverse events comprised the following: 1) improper selection of needle diameter for subcutaneous injection, material of infusion sets, and pore size of in-line filter; 2) complications associated with vascular access; 3) incidents induced by absence of efficient electronic pump management and infusion tube management; and 4) liquid leakage of chemotherapeutic infusion around the syringe needle. Safe injection drug use was enhanced by multidisciplinary collaboration, especially among pharmacists and nurses; drafting of clinical pathways in selection of vascular access; application of approaches such as root cause analysis using a fishbone diagram; plan-do-check-act and quality control circle; and construction of a culture of spontaneous reporting of near misses and adverse events. Pharmacists must be professional in regards to medication management and use. The depth, breadth, and efficiency of cooperation between nurses and pharmacists are pivotal to injection safety.

  4. DWARF GALAXY CLUSTERING AND MISSING SATELLITES

    International Nuclear Information System (INIS)

    Carlberg, R. G.; Sullivan, M.; Le Borgne, D.

    2009-01-01

    At redshifts around 0.1 the Canada-France-Hawaii Telescope Legacy Survey Deep fields contain some 6 x 10 4 galaxies spanning the mass range from 10 5 to 10 12 M sun . We measure the stellar mass dependence of the two-point correlation using angular measurements to largely bypass the errors, approximately 0.02 in the median, of the photometric redshifts. Inverting the power-law fits with Limber's equation we find that the autocorrelation length increases from a very low 0.4 h -1 Mpc at 10 5.5 M sun to the conventional 4.5 h -1 Mpc at 10 10.5 M sun . The power-law fit to the correlation function has a slope which increases from γ ≅ 1.6 at high mass to γ ≅ 2.3 at low mass. The spatial cross-correlation of dwarf galaxies with more massive galaxies shows fairly similar trends, with a steeper radial dependence at low mass than predicted in numerical simulations of subhalos within galaxy halos. To examine the issue of 'missing satellites' we combine the cross-correlation measurements with our estimates of the low-mass galaxy number density. We find on the average there are 60 ± 20 dwarfs in subhalos with M(total)>10 7 M sun for a typical Local Group M(total)/M(stars) = 30, corresponding to M/L V ≅ 100 for a galaxy with no recent star formation. The number of dwarfs per galaxy is about a factor of 2 larger than currently found for the Milky Way. Nevertheless, the average dwarf counts are about a factor of 30 below lambda cold dark matter (LCDM) simulation results. The divergence from LCDM predictions is one of the slope of the relation, approximately dN/dln M ≅ -0.5 rather than the predicted -0.9, not sudden onset at some characteristic scale. The dwarf galaxy star formation rates span the range from passive to bursting, which suggests that there are few completely dark halos.

  5. Near-miss maternal morbidity from severe haemorrhage at ...

    African Journals Online (AJOL)

    ... at caesarean section: A process and structure audit of system deficiencies in South Africa. ... The Donabedian model assumes that clinical outcomes are influenced by ... Dominant risk factors for near misses were previous caesarean section ...

  6. The role of proxy information in missing data analysis.

    Science.gov (United States)

    Huang, Rong; Liang, Yuanyuan; Carrière, K C

    2005-10-01

    This article investigates the role of proxy data in dealing with the common problem of missing data in clinical trials using repeated measures designs. In an effort to avoid the missing data situation, some proxy information can be gathered. The question is how to treat proxy information, that is, is it always better to utilize proxy information when there are missing data? A model for repeated measures data with missing values is considered and a strategy for utilizing proxy information is developed. Then, simulations are used to compare the power of a test using proxy to simply utilizing all available data. It is concluded that using proxy information can be a useful alternative when such information is available. The implications for various clinical designs are also considered and a data collection strategy for efficiently estimating parameters is suggested.

  7. ATLAS event featuring two charm jets and missing energy

    CERN Multimedia

    ATLAS Collaboration

    2012-01-01

    Proton collision event in the ATLAS detector featuring two tagged charm jets and missing transverse energy. The zoomed view in the bottom right panel shows a displaced vertex of one of the c-tagged jets (marked in blue).

  8. Missing Links: Gender Equity in Science and Technology for ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Missing Links: Gender Equity in Science and Technology for Development. Book cover ... Gender Working Group of the United Nations Commission on Science and Technology for Development. Publisher(s): ... Knowledge. Innovation.

  9. 40 CFR 98.55 - Procedures for estimating missing data.

    Science.gov (United States)

    2010-07-01

    ... accounting purposes (such as sales records). (b) For missing values related to the performance test, including emission factors, production rate, and N2O concentration, you must conduct a new performance test...

  10. 40 CFR 98.225 - Procedures for estimating missing data.

    Science.gov (United States)

    2010-07-01

    ... accounting purposes (such as sales records). (b) For missing values related to the performance test, including emission factors, production rate, and N2O concentration, you must conduct a new performance test...

  11. Prevalence and Correlates of Missed First Appointments among ...

    African Journals Online (AJOL)

    quality of care, results in poor treatment outcomes and drains financial resources. In Nigeria, where mental .... and physical aggression. Each subscale has four .... missed first appointments observed in this study falls within the range of 17 and ...

  12. Missed injury – decreasing morbidity and mortality: A literature review

    African Journals Online (AJOL)

    Advanced Trauma Life Support®), although they may also be inju- ries identified after a defined .... highly recommended for practice quality assurance. ... when injuries are missed, continuous audit is essential in prevent- ing repeated errors!

  13. Estimating range of influence in case of missing spatial data

    DEFF Research Database (Denmark)

    Bihrmann, Kristine; Ersbøll, Annette Kjær

    2015-01-01

    BACKGROUND: The range of influence refers to the average distance between locations at which the observed outcome is no longer correlated. In many studies, missing data occur and a popular tool for handling missing data is multiple imputation. The objective of this study was to investigate how...... the estimated range of influence is affected when 1) the outcome is only observed at some of a given set of locations, and 2) multiple imputation is used to impute the outcome at the non-observed locations. METHODS: The study was based on the simulation of missing outcomes in a complete data set. The range...... of influence was estimated from a logistic regression model with a spatially structured random effect, modelled by a Gaussian field. Results were evaluated by comparing estimates obtained from complete, missing, and imputed data. RESULTS: In most simulation scenarios, the range estimates were consistent...

  14. Computerized Analysis and Detection of Missed Cancer in Screening Mammogram

    National Research Council Canada - National Science Library

    Li, Lihua

    2005-01-01

    This project is to explore an innovative CAD strategy for improving early detection of breast cancer in screening mammograms by focusing on computerized analysis and detection of cancers missed by radiologists...

  15. Computerized Analysis and Detection of Missed Cancer in Screening Mammogram

    National Research Council Canada - National Science Library

    Li, Lihua

    2004-01-01

    This project is to explore an innovative CAD strategy for improving early detection of breast cancer in screening mammograms by focusing on computerized analysis and detection of cancers missed by radiologists...

  16. Prevalence and Correlates of Missed First Appointments among ...

    African Journals Online (AJOL)

    In Nigeria, where mental health services are poorly organized, missed appointments and its resultant consequences may be burdensome. Aim: This ... However, having received previous treatment for a psychiatric illness (P = 0.02) and having ...

  17. missed opportunities for the diagnosis of pulmonary tuberculosis

    African Journals Online (AJOL)

    User

    MISSED OPPORTUNITIES FOR THE DIAGNOSIS OF. PULMONARY .... Data analysis. Data were pooled across all sites for analysis. .... tecting 70% of new smear positive cases by. 2005 (case ... False negative is one big factor with smear ...

  18. SQL Injection Attacks and Defense

    CERN Document Server

    Clarke, Justin

    2012-01-01

    SQL Injection Attacks and Defense, First Edition: Winner of the Best Book Bejtlich Read Award "SQL injection is probably the number one problem for any server-side application, and this book unequaled in its coverage." -Richard Bejtlich, Tao Security blog SQL injection represents one of the most dangerous and well-known, yet misunderstood, security vulnerabilities on the Internet, largely because there is no central repository of information available for penetration testers, IT security consultants and practitioners, and web/software developers to turn to for help. SQL Injection Att

  19. Injectable barriers for waste isolation

    International Nuclear Information System (INIS)

    Persoff, P.; Finsterle, S.; Moridis, G.J.; Apps, J.; Pruess, K.; Muller, S.J.

    1995-03-01

    In this paper the authors report laboratory work and numerical simulation done in support of development and demonstration of injectable barriers formed from either of two fluids: colloidal silica or polysiloxane. Two principal problems addressed here are control of gel time and control of plume emplacement in the vadose zone. Gel time must be controlled so that the viscosity of the barrier fluid remains low long enough to inject the barrier, but increases soon enough to gel the barrier in place. During injection, the viscosity must be low enough to avoid high injection pressures which could uplift or fracture the formation. To test the grout gel time in the soil, the injection pressure was monitored as grouts were injected into sandpacks. When grout is injected into the vadose zone, it slumps under the influence of gravity, and redistributes due to capillary forces as it gels. The authors have developed a new module for the reservoir simulator TOUGH2 to model grout injection into the vadose zone, taking into account the increase of liquid viscosity as a function of gel concentration and time. They have also developed a model to calculate soil properties after complete solidification of the grout. The numerical model has been used to design and analyze laboratory experiments and field pilot tests. The authors present the results of computer simulations of grout injection, redistribution, and solidification

  20. Safe Injection Practices in Primary Health Care Settings of Naxalbari Block, Darjeeling District, West Bengal.

    Science.gov (United States)

    Chaudhuri, Sudip Banik; Ray, Kuntala

    2016-01-01

    Unsafe injection can transmit many diseases to patients, injection providers and healthy people of community. To find out critical steps whether executed according to recommended best practice methods, availability of equipments in health facilities for safe injection practices and some important steps of waste disposal methods. This facility-based cross-sectional observational study was conducted among 30 Auxiliary nurse midwives (ANM) & 27 nursing staffs (NS) to assess certain aspects of their practice while administrating injection and disposal of the disposables. Health facilities were also observed to asses necessary equipments of safe injection and waste disposal methods. Among the health workers 93.3% ANM and 100% NS took sterile syringe from sterile unopened packet, all of the study subjects washed hand before giving injection, 13.3% of ANMs and 8% of NS are fully vaccinated against Hep B, 53.3% of ANM and all NS are practices non recapping. Only 13.33% sub centres along with PHC & BPHC had at least one puncture resistant leak proof container, 86.7% sub centres, PHC are free from loose needles. Transport for off side treatment is the method of waste disposal in case of 73.3% cases sub centres, PHC & BPHC. There is need to educate, train and motivate service providers in proper methods of giving injection along with improve the adequacy of supply of required equipments.

  1. Maternal near-miss in a rural hospital in Sudan

    Directory of Open Access Journals (Sweden)

    Adam Gamal K

    2011-06-01

    Full Text Available Abstract Background Investigation of maternal near-miss is a useful complement to the investigation of maternal mortality with the aim of meeting the United Nations' fifth Millennium Development Goal. The present study was conducted to investigate the frequency of near-miss events, to calculate the mortality index for each event and to compare the socio-demographic and obstetrical data (age, parity, gestational age, education and antenatal care of the near-miss cases with maternal deaths. Methods Near-miss cases and events (hemorrhage, infection, hypertensive disorders, anemia and dystocia, maternal deaths and their causes were retrospectively reviewed and the mortality index for each event was calculated in Kassala Hospital, eastern Sudan over a 2-year period, from January 2008 to December 2010. Disease-specific criteria were applied for these events. Results There were 9578 deliveries, 205 near-miss cases, 228 near-miss events and 40 maternal deaths. Maternal near-miss and maternal mortality ratio were 22.1/1000 live births and 432/100 000 live births, respectively. Hemorrhage accounted for the most common event (40.8%, followed by infection (21.5%, hypertensive disorders (18.0%, anemia (11.8% and dystocia (7.9%. The mortality index were 22.2%, 10.0%, 10.0%, 8.8% and 2.4% for infection, dystocia, anemia, hemorrhage and hypertensive disorders, respectively. Conclusion There is a high frequency of maternal morbidity and mortality at the level of this facility. Therefore maternal health policy needs to be concerned not only with averting the loss of life, but also with preventing or ameliorating maternal-near miss events (hemorrhage, infections, hypertension and anemia at all care levels including primary level.

  2. Diabetes or hypertension as risk indicators for missing teeth ...

    African Journals Online (AJOL)

    A negative binomial regression (NBR) model was generated. Results: Mean age was 50.7 ± 16.2 and 50.0% were women. Mean number of missing teeth was 4.98 ± 4.17. In the multivariate NBR model, we observed that individuals with T2DM had higher risk of more missing teeth (incidence rate ratios [IRRs] = 3.13; 95% ...

  3. Alternative Fuels Data Center: Biodiesel Equipment Options

    Science.gov (United States)

    Equipment Options to someone by E-mail Share Alternative Fuels Data Center: Biodiesel Equipment Options on Facebook Tweet about Alternative Fuels Data Center: Biodiesel Equipment Options on Twitter Bookmark Alternative Fuels Data Center: Biodiesel Equipment Options on Google Bookmark Alternative Fuels

  4. 40 CFR 792.61 - Equipment design.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Equipment design. 792.61 Section 792.61...) GOOD LABORATORY PRACTICE STANDARDS Equipment § 792.61 Equipment design. Equipment used in the... of appropriate design and adequate capacity to function according to the protocol and shall be...

  5. 40 CFR 160.61 - Equipment design.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Equipment design. 160.61 Section 160... LABORATORY PRACTICE STANDARDS Equipment § 160.61 Equipment design. Equipment used in the generation... appropriate design and adequate capacity to function according to the protocol and shall be suitably located...

  6. 21 CFR 58.61 - Equipment design.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Equipment design. 58.61 Section 58.61 Food and... PRACTICE FOR NONCLINICAL LABORATORY STUDIES Equipment § 58.61 Equipment design. Equipment used in the... of appropriate design and adequate capacity to function according to the protocol and shall be...

  7. 34 CFR 74.34 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... as program income. (e) When acquiring replacement equipment, the recipient may use the equipment to... replacement equipment subject to the approval of the Secretary. (f) The recipient's property management... 34 Education 1 2010-07-01 2010-07-01 false Equipment. 74.34 Section 74.34 Education Office of the...

  8. 20 CFR 437.32 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... contemplated by Federal statute. (4) When acquiring replacement equipment, the grantee or subgrantee may use.... Procedures for managing equipment (including replacement equipment), whether acquired in whole or in part... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Equipment. 437.32 Section 437.32 Employees...

  9. 45 CFR 2541.320 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... replacement equipment, the grantee or subgrantee may use the equipment to be replaced as a trade-in or sell... replacement equipment), whether acquired in whole or in part with grant funds, until disposition takes place... ensure the highest possible return. (e) Disposition. When original or replacement equipment acquired...

  10. 45 CFR 1174.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... contemplated by Federal statute. (4) When acquiring replacement equipment, the grantee or subgrantee may use... requirements. Procedures for managing equipment (including replacement equipment), whether acquired in whole or... original or replacement equipment acquired under a grant or subgrant is no longer needed for the original...

  11. 45 CFR 1157.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... contemplated by Federal statute. (4) When acquiring replacement equipment, the grantee or subgrantee may use... requirements. Procedures for managing equipment (including replacement equipment), whether acquired in whole or... original or replacement equipment acquired under a grant or subgrant is no longer needed for the original...

  12. The Cost of Maintaining Educational Communications Equipment.

    Science.gov (United States)

    Humphrey, David A.

    Tentative formulas for calculating the cost of maintaining educational communications equipment are proposed. The formulas are based on a survey of campuses of the State University of New York. The survey analyzed the types of equipment to be maintained, types of maintenance, who uses the equipment, who services the equipment, and the cost…

  13. The oil and gas equipment and services market in Nigeria

    International Nuclear Information System (INIS)

    2003-01-01

    The oil and gas market in Nigeria is being expanded by the Nigerian government over the 2003-2010 period through increased exploration and production (E and P) in new areas. Other measures being implemented are the improvements of structural flaws that hamper industry growth, the modernization of the weak downstream sector, and attempts to attract foreign investment and technologies required for petroleum development. In 2001, it was estimated that the market for oil and gas equipment in Nigeria was approximately 1.03 billion dollars, and is expected to reach 1.15 billion dollars in 2002. In deep-sea areas, major offshore E and P projects are being planned by large oil multinationals. The implementation of several gas-related E and P operations and major liquefied natural gas (LNG) and gas-to-liquid (GTL) projects are being supported by the government of Nigeria to develop the natural gas sector. Onshore and offshore exploration, surveying and geophysical prospecting, drilling equipment, facilities maintenance, deepwater E and P, equipment for LNG/GTL facilities, enhanced recovery equipment and services, gas re-injection technology, pipelines, and the refinery sector are all areas where Canadian equipment and service suppliers could benefit from opportunities in Nigeria. One of the most prominent foreign player in the Nigerian market is Royal Dutch Shell. As far as the offshore deepwater E and P sub-sector, the three major players are Shell, ChevronTexaco, and ExxonMobil. The Nigerian government advocate in upstream and downstream oil industries in the country is Nigeria National Petroleum Corporation (NNPC). The primary domestic end-users of oil and gas equipment and services are member companies of the Nigerian Association of Indigenous Petroleum Exploration Companies (NAIPEC). Canadian companies are encouraged to form joint venture partnerships in oil and gas projects, as foreign majors operating in Nigeria tend to rely on the skills and expertise of foreign

  14. Exoatmospheric intercepts using zero effort miss steering for midcourse guidance

    Science.gov (United States)

    Newman, Brett

    The suitability of proportional navigation, or an equivalent zero effort miss formulation, for exatmospheric intercepts during midcourse guidance, followed by a ballistic coast to the endgame, is addressed. The problem is formulated in terms of relative motion in a general, three dimensional framework. The proposed guidance law for the commanded thrust vector orientation consists of the sum of two terms: (1) along the line of sight unit direction and (2) along the zero effort miss component perpendicular to the line of sight and proportional to the miss itself and a guidance gain. If the guidance law is to be suitable for longer range targeting applications with significant ballistic coasting after burnout, determination of the zero effort miss must account for the different gravitational accelerations experienced by each vehicle. The proposed miss determination techniques employ approximations for the true differential gravity effect and thus, are less accurate than a direct numerical propagation of the governing equations, but more accurate than a baseline determination, which assumes equal accelerations for both vehicles. Approximations considered are constant, linear, quadratic, and linearized inverse square models. Theoretical results are applied to a numerical engagement scenario and the resulting performance is evaluated in terms of the miss distances determined from nonlinear simulation.

  15. Spacecraft intercept guidance using zero effort miss steering

    Science.gov (United States)

    Newman, Brett

    The suitability of proportional navigation, or an equivalent zero effort miss formulation, for spacecraft intercepts during midcourse guidance, followed by a ballistic coast to the endgame, is addressed. The problem is formulated in terms of relative motion in a general 3D framework. The proposed guidance law for the commanded thrust vector orientation consists of the sum of two terms: (1) along the line of sight unit direction and (2) along the zero effort miss component perpendicular to the line of sight and proportional to the miss itself and a guidance gain. If the guidance law is to be suitable for longer range targeting applications with significant ballistic coasting after burnout, determination of the zero effort miss must account for the different gravitational accelerations experienced by each vehicle. The proposed miss determination techniques employ approximations for the true differential gravity effect. Theoretical results are applied to a numerical engagement scenario and the resulting performance is evaluated in terms of the miss distances determined from nonlinear simulation.

  16. Bayesian Sensitivity Analysis of Statistical Models with Missing Data.

    Science.gov (United States)

    Zhu, Hongtu; Ibrahim, Joseph G; Tang, Niansheng

    2014-04-01

    Methods for handling missing data depend strongly on the mechanism that generated the missing values, such as missing completely at random (MCAR) or missing at random (MAR), as well as other distributional and modeling assumptions at various stages. It is well known that the resulting estimates and tests may be sensitive to these assumptions as well as to outlying observations. In this paper, we introduce various perturbations to modeling assumptions and individual observations, and then develop a formal sensitivity analysis to assess these perturbations in the Bayesian analysis of statistical models with missing data. We develop a geometric framework, called the Bayesian perturbation manifold, to characterize the intrinsic structure of these perturbations. We propose several intrinsic influence measures to perform sensitivity analysis and quantify the effect of various perturbations to statistical models. We use the proposed sensitivity analysis procedure to systematically investigate the tenability of the non-ignorable missing at random (NMAR) assumption. Simulation studies are conducted to evaluate our methods, and a dataset is analyzed to illustrate the use of our diagnostic measures.

  17. Software for handling and replacement of missing data

    Directory of Open Access Journals (Sweden)

    Mayer, Benjamin

    2009-10-01

    Full Text Available In medical research missing values often arise in the course of a data analysis. This fact constitutes a problem for different reasons, so e.g. standard methods for analyzing data lead to biased estimates and a loss of statistical power due to missing values, since those methods require complete data sets and therefore omit incomplete cases for the analyses. Furthermore missing values imply a certain loss of information for what reason the validity of results of a study with missing values has to be rated less than in a case where all data had been available. For years there are methods for replacement of missing values (Rubin, Schafer to tackle these problems and solve them in parts. Hence in this article we want to present the existing software to handle and replace missing values on the one hand and give an outline about the available options to get information on the other hand. The methodological aspects of the replacement strategies are delineated just briefly in this article.

  18. Posttraumatic stress disorder in women with war missing family members.

    Science.gov (United States)

    Baraković, Devla; Avdibegović, Esmina; Sinanović, Osman

    2014-12-01

    Research in crisis areas indicate that survivors' responses to the forced disappearance of family members are similar to reactions to other traumatic events. The aim of this study was to determine the presence of symptoms of posttraumatic stress disorder (PTSD) in women with war missing family members in Bosnia and Herzegovina 18 years after the war in this region (1992-1995). The study included 160 women aged 47.1±14.0 from three regions of Bosnia and Herzegovina. It was carried out in the period from April 2010 to May 2011. Of the 160 participants, 120 women had a war missing family member and 40 women had no war missing family members. The Harvard Trauma Questionnaire (HTQ), the Beck Depression Inventory (BDI) and the Hamilton Anxiety Rating Scale (HAMA) were used for data collection. Basic socio-demographic data and data concerning the missing family members were also collected. Women with war missing family members experienced significantly more traumatic war experiences (18.43±5.27 vs 6.57±4.34, pfamily members. Women with war missing family members showed significantly more severe PTSD symptoms. Based on the results of this study, it was determined that the forced disappearance of a family member is an ambiguous situation that can be characterized as a traumatic experience.

  19. Dentistry to the rescue of missing children: A review

    Science.gov (United States)

    Vij, Nitika; Kochhar, Gulsheen Kaur; Chachra, Sanjay; Kaur, Taranjot

    2016-01-01

    Today's society is becoming increasingly unsafe for children: we frequently hear about new incidents of missing children, which lead to emotional trauma for the loved ones and expose systemic failures of law and order. Parents can take extra precautions to ensure the safety of their children by educating them about ways to protect themselves and keep important records of the child such as updated color photographs, fingerprints, deoxyribonucleic acid (DNA) samples, etc., handy. However, in spite of all efforts, the problem of missing children still remains. Developments in the field of dentistry have empowered dentists with various tools and techniques to play a pivotal role in tracing a missing child. One such tool is Toothprints, a patented arch-shaped thermoplastic dental impression wafer developed by Dr. David Tesini, a paediatric dentist from Massachusetts. Toothprints enables a unique identification of the missing children not only through the bite impression but also through salivary DNA. Besides the use of Toothprints, a dentist can assist investigating agencies in identifying the missing children in multiple ways, including postmortem dental profiling, labeled dental fixtures, DNA extraction from teeth, and serial number engraving on the children's teeth. More importantly, all these tools cause minimal inconvenience to the individual, making a dentist's role in tracking a missing child even more significant. Thus, the simple discipline of maintaining timely dental records with the help of their dentists can save potential hassles for the parents in the future. PMID:27051216

  20. Imputation of missing data in time series for air pollutants

    Science.gov (United States)

    Junger, W. L.; Ponce de Leon, A.

    2015-02-01

    Missing data are major concerns in epidemiological studies of the health effects of environmental air pollutants. This article presents an imputation-based method that is suitable for multivariate time series data, which uses the EM algorithm under the assumption of normal distribution. Different approaches are considered for filtering the temporal component. A simulation study was performed to assess validity and performance of proposed method in comparison with some frequently used methods. Simulations showed that when the amount of missing data was as low as 5%, the complete data analysis yielded satisfactory results regardless of the generating mechanism of the missing data, whereas the validity began to degenerate when the proportion of missing values exceeded 10%. The proposed imputation method exhibited good accuracy and precision in different settings with respect to the patterns of missing observations. Most of the imputations obtained valid results, even under missing not at random. The methods proposed in this study are implemented as a package called mtsdi for the statistical software system R.

  1. Dentistry to the rescue of missing children: A review.

    Science.gov (United States)

    Vij, Nitika; Kochhar, Gulsheen Kaur; Chachra, Sanjay; Kaur, Taranjot

    2016-01-01

    Today's society is becoming increasingly unsafe for children: we frequently hear about new incidents of missing children, which lead to emotional trauma for the loved ones and expose systemic failures of law and order. Parents can take extra precautions to ensure the safety of their children by educating them about ways to protect themselves and keep important records of the child such as updated color photographs, fingerprints, deoxyribonucleic acid (DNA) samples, etc., handy. However, in spite of all efforts, the problem of missing children still remains. Developments in the field of dentistry have empowered dentists with various tools and techniques to play a pivotal role in tracing a missing child. One such tool is Toothprints, a patented arch-shaped thermoplastic dental impression wafer developed by Dr. David Tesini, a paediatric dentist from Massachusetts. Toothprints enables a unique identification of the missing children not only through the bite impression but also through salivary DNA. Besides the use of Toothprints, a dentist can assist investigating agencies in identifying the missing children in multiple ways, including postmortem dental profiling, labeled dental fixtures, DNA extraction from teeth, and serial number engraving on the children's teeth. More importantly, all these tools cause minimal inconvenience to the individual, making a dentist's role in tracking a missing child even more significant. Thus, the simple discipline of maintaining timely dental records with the help of their dentists can save potential hassles for the parents in the future.

  2. A comparison of molding procedures - Contact, injection and vacuum injection

    Science.gov (United States)

    Cathiard, G.

    1980-06-01

    The technical and economic aspects of the contact, injection and vacuum injection molding of reinforced plastic components are compared for the example of a tractor roof with a gel-coated surface. Consideration is given to the possibility of reinforcement, number of smooth faces, condition of the gel-coated surface, reliability, and labor and workplace requirements of the three processes, and advantages of molding between the mold and a countermold in smooth faces, reliability, labor requirements, working surface and industrial hygiene are pointed out. The times and labor requirements of each step in the molding cycles are examined, and material requirements and yields, investment costs, amortization and product cost prices of the processes are compared. It is concluded that, for the specific component examined, the processes of vacuum injection and injection molding appear very interesting, with injection molding processes resulting in lower cost prices than contact molding for any production volume.

  3. "Vivo para consumirla y la consumo para vivir" ["I live to inject and inject to live"]: high-risk injection behaviors in Tijuana, Mexico.

    Science.gov (United States)

    Strathdee, Steffanie A; Fraga, Wendy Davila; Case, Patricia; Firestone, Michelle; Brouwer, Kimberly C; Perez, Saida Gracia; Magis, Carlos; Fraga, Miguel Angel

    2005-09-01

    Injection drug use is a growing problem on the US-Mexico border, where Tijuana is situated. We studied the context of injection drug use among injection drug users (IDUs) in Tijuana to help guide future research and interventions. Guided in-depth interviews were conducted with 10 male and 10 female current IDUs in Tijuana. Topics included types of drug used, injection settings, access to sterile needles, and environmental influences. Interviews were taped, transcribed verbatim, and translated. Content analysis was conducted to identify themes. Of the 20 IDUs, median age and age at first injection were 30 and 18. Most reported injecting at least daily: heroin ("carga", "chiva", "negra"), methamphetamine ("crico", "cri-cri"), or both drugs combined. In sharp contrast to Western US cities, almost all regularly attended shooting galleries ("yongos" or "picaderos") because of the difficulties obtaining syringes and police oppression. Almost all shared needles/paraphernalia ["cuete" (syringe), "cacharros" (cookers), cotton from sweaters/socks (filters)]. Some reported obtaining syringes from the United States. Key themes included (1) pharmacies refusing to sell or charging higher prices to IDUs, (2) ample availability of used/rented syringes from "picaderos" (e.g., charging approximately 5 pesos or "10 drops" of drug), and (3) poor HIV/AIDS knowledge, such as beliefs that exposing syringes to air "kills germs." This qualitative study suggests that IDUs in Tijuana are at high risk of HIV and other blood-borne infections. Interventions are urgently needed to expand access to sterile injection equipment and offset the potential for a widespread HIV epidemic.

  4. Cooling water injection system

    International Nuclear Information System (INIS)

    Inai, Nobuhiko.

    1989-01-01

    In a BWR type reactor, ECCS system is constituted as a so-called stand-by system which is not used during usual operation and there is a significant discontinuity in relation with the usual system. It is extremely important that ECCS operates upon occurrence of accidents just as specified. In view of the above in the present invention, the stand-by system is disposed along the same line with the usual system. That is, a driving water supply pump for supplying driving water to a jet pump is driven by a driving mechanism. The driving mechanism drives continuously the driving water supply pump in a case if an expected accident such as loss of the function of the water supply pump, as well as during normal operation. That is, all of the water supply pump, jet pump, driving water supply pump and driving mechanism therefor are caused to operate also during normal operation. The operation of them are not initiated upon accident. Thus, the cooling water injection system can perform at high reliability to remarkably improve the plant safety. (K.M.)

  5. Upgrade of the LHC Injection Kicker Magnets

    CERN Document Server

    Barnes, M J; Baglin, V; Bregliozzi, G; Caspers, F; Calatroni, S; Day, H; Ducimetière, L; Garlaschè, M; Gomes Namora, V; Jimenez, J M; Magnin, N; Mertens, V; Métral, E; Salvant, B; Taborelli, M; Uythoven, J; Weterings, W

    2013-01-01

    Two LHC injection kicker systems, each comprising 4 magnets per ring, produce a kick of 1.3 T·m with a rise-time of less than 900 ns and a flattop ripple of less than ±0.5%. A beam screen is placed in the aperture of each magnet, to provide a path for the image current of the LHC beam and screen the ferrite yoke against wake fields. The screen consists of a ceramic tube with conductors in the inner wall. The initially implemented beam screen ensured a low rate of electrical breakdowns and an adequately low beam coupling impedance. Operation with increasingly higher intensity beams, stable for many hours at a time, has resulted in substantial heating of the ferrite yoke, sometimes requiring cool-down over several hours before the LHC can be refilled. During the long shutdown in 2013/2014 all eight kicker magnets will be upgraded with an improved beam screen and an increased emissivity of the vacuum tank. In addition equipment adjacent to the injection kickers and various vacuum components will be modified to...

  6. Steam injection to increase oil recovery

    Energy Technology Data Exchange (ETDEWEB)

    Leutwyler, K; Bigelow, H L

    1966-03-01

    Speculation is made as to the possibility that future reserves can be increased with steam energy from the first day of production. Boilers and auxilary equipment for this operation should be designed especially for free air operations. The appropriate treatment of the water used is critical in controlling certain problems. Since this operation has been planned for working at temperatures of approximately 315$C, one of the best downhole units for such an operation is found to be the Retrievable Thermal Seal Packer. Expansion joints solve the problem of temperature inhibiting movement causing permanent corkscrew deformity. Conventional sealing material on the tubing threads is not suitable at high temperatures. A band of Teflon does the job well but its use is unjustified by cost and personnel untrained in its use. However, an excellent sealing material has been developed that fills all requirements. General suggestions for the use of steam injection include the good cementing jobs; treatment of the entire system as an integral unit; use of asbestos to insulate is of doubtful value because of the subsequent problems it causes; starting of the steam injection conservatively allows the cement and tubing to heat together. It is believed that this procedure helps reduce the possibility of vertical fractures in the cement.

  7. Simulation and control of a HD diesel engine equipped with new EGR technology

    NARCIS (Netherlands)

    Dekker, H.J.; Sturm, W.L.

    1996-01-01

    A dynamic model of a Heavy Duty (HD) turbocharged and aftercooled diesel engine was developed. The engine was equipped with high pressure diesel injection, a Variable Geometry Turbine (VGT) and an Exhaust Gas Recirculation (EGR) system. This engine was targeted at meeting EURO4 emission

  8. Governance or Governing – the Missing Link?

    Directory of Open Access Journals (Sweden)

    Luminiţa Maria Crăciun

    2010-07-01

    , of giving a sense of responsibility to the public and private sectors, of imposing, observing and materializing a real commitment for preventing and fighting corruption, the risk of which may be a threat to national security. Human governance creates a favorable environment for human development and elimination of poverty. If the preoccupations of the governance institutions are centered on the interests, needs, and fundamental rights of the population, progress may be achieved in the fight against poverty. If a country tries to apply economic policies in order to promote a beneficial increase to the poor ones, along with programs meant to help reach the targeted goals, the effects may be attenuated or annulled, when the governance institutions are ineffective or passive. The conclusion is that the governance is the missing link between the efforts of struggle against poverty and reaching the objective of poverty reduction.

  9. Single-use autoinjector for once-weekly intramuscular injection of IFNβ-1a.

    Science.gov (United States)

    Limmroth, Volker; Gerbershagen, Kathrin

    2014-12-01

    IFNβ products and glatiramer acetate are established treatment first-line options in long-term disease-modifying therapy of multiple sclerosis (MS). These self-injectable medications are used once weekly to once daily. Injection-related issues are common patient-cited reasons for nonadherence. Autoinjectors have been shown to support long-term adherence to injectable medications. The ability to self-inject in MS patients has been associated with a reduced risk of missed injections and drug discontinuation, and a beneficial effect on patient independence. The recently introduced easy-to-use prefilled once-weekly pen is a safe and effective device for intramuscular (IM) IFNβ-1a application and provides a convenient method for self-injection. We reviewed the available published evidence on the characteristics of this device. The once-weekly pen facilitates self-injection and was preferred over prefilled syringes by patients in a prospective open-label, multicenter Phase IIIb trial in MS patients who had been using IM IFNβ-1a in prefilled syringes. The simple and safe handling, shielded short needle, single-use disposable design and virtually painless injection by the device may contribute to adherence, quality of life and independence in patients using IM IFNβ-1a.

  10. [Equipment and technology in robotics].

    Science.gov (United States)

    Murphy, Declan; Challacombe, Ben; Nedas, Tim; Elhage, Oussama; Althoefer, Kaspar; Seneviratne, Lakmal; Dasgupta, Prokar

    2007-05-01

    We review the evolution and current status of robotic equipment and technology in urology. We also describe future developments in the key areas of virtual reality simulation, mechatronics and nanorobotics. The history of robotic technology is reviewed and put into the context of current systems. Experts in the associated fields of nanorobotics, mechatronics and virtual reality simulation simulation review the important future developments in these areas.

  11. Remote handling equipment for SNS

    International Nuclear Information System (INIS)

    Poulten, B.H.

    1983-01-01

    This report gives information on the areas of the SNS, facility which become highly radioactive preventing hands-on maintenance. Levels of activity are sufficiently high in the Target Station Area of the SNS, especially under fault conditions, to warrant reactor technology to be used in the design of the water, drainage and ventilation systems. These problems, together with the type of remote handling equipment required in the SNS, are discussed

  12. Margins related to equipment design

    International Nuclear Information System (INIS)

    Devos, J.

    1994-01-01

    Safety margins related to design of reactor equipment are defined according to safety regulations. Advanced best estimate methods are proposed including some examples which were computed and compared to experimental results. Best estimate methods require greater computation effort and more material data but give better variable accuracy and need careful experimental validation. Simplified methods compared to the previous are less sensitive to material data, sometimes are more accurate but very long to elaborate

  13. Temperature radiation measuring equipment. Temperaturstrahlungsmessgeraet

    Energy Technology Data Exchange (ETDEWEB)

    Lotzer, W

    1981-01-22

    The invention is concerned with a temperature radiation measuring equipment for non-contact temperature measurement by the light intensity variation method, with a photoelectric resistance as the measuring element. By having a circuit with a transistor, the 'dark resistance' occurring in the course of time is compensated for and thus gives a genuine reading (ie. the voltage drop across the photoelectric resistance remains constant).

  14. Missing data in trauma registries: A systematic review.

    Science.gov (United States)

    Shivasabesan, Gowri; Mitra, Biswadev; O'Reilly, Gerard M

    2018-03-30

    Trauma registries play an integral role in trauma systems but their valid use hinges on data quality. The aim of this study was to determine, among contemporary publications using trauma registry data, the level of reporting of data completeness and the methods used to deal with missing data. A systematic review was conducted of all trauma registry-based manuscripts published from 01 January 2015 to current date (17 March 2017). Studies were identified by searching MEDLINE, EMBASE, and CINAHL using relevant subject headings and keywords. Included manuscripts were evaluated based on previously published recommendations regarding the reporting and discussion of missing data. Manuscripts were graded on their degree of characterization of such observations. In addition, the methods used to manage missing data were examined. There were 539 manuscripts that met inclusion criteria. Among these, 208 (38.6%) manuscripts did not mention data completeness and 88 (16.3%) mentioned missing data but did not quantify the extent. Only a handful (n = 26; 4.8%) quantified the 'missingness' of all variables. Most articles (n = 477; 88.5%) contained no details such as a comparison between patient characteristics in cohorts with and without missing data. Of the 331 articles which made at least some mention of data completeness, the method of managing missing data was unknown in 34 (10.3%). When method(s) to handle missing data were identified, 234 (78.8%) manuscripts used complete case analysis only, 18 (6.1%) used multiple imputation only and 34 (11.4%) used a combination of these. Most manuscripts using trauma registry data did not quantify the extent of missing data for any variables and contained minimal discussion regarding missingness. Out of the studies which identified a method of managing missing data, most used complete case analysis, a method that may bias results. The lack of standardization in the reporting and management of missing data questions the validity of

  15. H- charge exchange injection systems

    International Nuclear Information System (INIS)

    Ankenbrandt, C.; Curtis, C.; Hojvat, C.; Johnson, R.P.; Owen, C.; Schmidt, C.; Teng, L.; Webber, R.C.

    1980-01-01

    The techniques and components required for injection of protons into cyclic accelerators by means of H - charge exchange processes are reviewed, with emphasis on the experience at Fermilab. The advantages of the technique are described. The design and performance of the system of injection of H - ions into the Fermilab Booster are detailed. (Auth.)

  16. Injection and lessons for 2012

    International Nuclear Information System (INIS)

    Bracco, C.; Barnes, M.J.; Bartmann, W.; Cornelis, K.; Drosdal, L.N.; Goddard, B.; Kain, V.; Meddahi, M.; Mertens, V.; Uythoven, J.

    2012-01-01

    Injection of 144 bunches into the LHC became fully operational during the 2011 run and one nominal injection of 288 bunches was accomplished. Several mitigation solutions were put in place to minimise losses from the Transfer Line (TL) collimators and losses from kicking de-bunched beam during injection. Nevertheless, shot-by- shot and bunch-by-bunch trajectory variations, as well as long terms drifts, were observed and required a regular re-steering of the TL implying a non negligible amount of time spent for injection setup. Likely sources of instability have been identified (i.e. MKE and MSE ripples) and possible cures to optimise 2012 operation are presented. Well defined references for TL steering will be defined in a more rigorous way in order to allow a more straightforward and faster injection setup. Encountered and potential issues of the injection system, in particular the injection kickers MKI, are discussed also in view of injections with a higher number of bunches. (authors)

  17. Injection and lessons for 2012

    CERN Document Server

    Bracco, C; Bartmann, W; Cornelis, K; Drosdal, L N; Goddard, B; Kain, V; Meddahi, M; Mertens, V; Uythoven, J

    2012-01-01

    Injection of 144 bunches into the LHC became fully operational during the 2011 run and a nominal injection of 288 bunches was accomplished during MD time. Several mitigation solutions were put in place to minimise losses from the transfer line (TL) collimators and losses from kicking debunched beam during injection. Nevertheless, shot-by-shot and bunch-by-bunch trajectory variations, as well as long terms drifts, were observed and required a regular resteering of the TL implying a non negligible amount of time spent for injection setup. Likely sources of instability have been identified (i.e. MKE and MSE ripples) and possible cures to optimise 2012 operation are presented. Well defined references for TL steering will be defined in a more rigorous way in order to allow a more straightforward and faster injection setup. Encountered and potential issues of the injection system, in particular the injection kickers MKI, are discussed also in view of injections with a higher number of bunches.

  18. Towards spin injection into silicon

    Energy Technology Data Exchange (ETDEWEB)

    Dash, S.P.

    2007-08-15

    Si has been studied for the purpose of spin injection extensively in this thesis. Three different concepts for spin injection into Si have been addressed: (1) spin injection through a ferromagnet-Si Schottky contact, (2) spin injection using MgO tunnel barriers in between the ferromagnet and Si, and (3) spin injection from Mn-doped Si (DMS) as spin aligner. (1) FM-Si Schottky contact for spin injection: To be able to improve the interface qualities one needs to understand the atomic processes involved in the formation of silicide phases. In order to obtain more detailed insight into the formation of such phases the initial stages of growth of Co and Fe were studied in situ by HRBS with monolayer depth resolution.(2) MgO tunnel barrier for spin injection into Si: The fabrication and characterization of ultra-thin crystalline MgO tunnel barriers on Si (100) was presented. (3) Mn doped Si for spin injection: Si-based diluted magnetic semiconductor samples were prepared by doping Si with Mn by two different methods i) by Mn ion implantation and ii) by in-diffusion of Mn atoms (solid state growth). (orig.)

  19. CERN computing equipment for Senegal

    CERN Multimedia

    Anaïs Schaeffer

    2014-01-01

    On 26 May, CERN once again had the honour of donating computing equipment to a foreign institute.   This time, around 100 servers and five network hubs were sent to Senegal, making it the seventh country, after Morocco, Ghana, Bulgaria, Serbia, Egypt and the Philippines, to receive a donation of computing equipment from the Organization. The official ceremony was held at CERN on 26 May in the presence of the Director-General, Rolf Heuer, and Senegal's ambassador to Geneva, Fodé Seck, who both expressed their enthusiasm for the project. The equipment is intended for Cheikh Anta Diop University (UCAD) in Dakar and will be of particular use to students attending the African School of Fundamental Physics and its Applications (ASP 2014) taking place from 3 to 23 August, for which CERN is a partner. The ASP allows a large number of African students to hone their skills in high-energy physics and to forge professional links with fellow physicists in Africa and Europe. ...

  20. CT guided diagnostic foot injections

    International Nuclear Information System (INIS)

    Saifuddin, A.; Abdus-Samee, M.; Mann, C.; Singh, D.; Angel, J.C.

    2005-01-01

    AIM: To describe a CT technique for guiding diagnostic and therapeutic injections in the hind- and mid-foot. MATERIALS AND METHODS: Over a period of 50 months, 28 individuals were referred for diagnostic and therapeutic hind- and mid-foot injections before possible arthrodesis. A CT technique was developed that allowed entry into the various joints using a vertical approach. Numbers of joints injected were as follows: posterior subtalar, 21; talonavicular, 4; calcaneonavicular, calcaneocuboid, navicular-cuneiform and 5th metatarsocuboid joints, 1 each. RESULTS: All injections but one were technically successful. Significant relief of symptoms was noted by 16 participants, whereas for 9 there was no improvement and for 3 a partial response was achieved. CONCLUSION: CT is a simple and safe alternative to fluoroscopy for guiding diagnostic and therapeutic foot injections, and may be the technique of choice in cases of disordered anatomy