  1. Multiple unit root tests under uncertainty over the initial condition : some powerful modifications

    NARCIS (Netherlands)

    Hanck, C.

    We modify the union-of-rejection unit root test of Harvey et al. "Unit Root Testing in Practice: Dealing with Uncertainty over the Trend and Initial Condition" (Harvey, Econom Theory 25:587-636, 2009). This test rejects if either of two different unit root tests rejects but controls the inherent

  2. Ground Operations Demonstration Unit for Liquid Hydrogen Initial Test Results

    Science.gov (United States)

    Notardonato, W. U.; Johnson, W. L.; Swanger, A. M.; Tomsik, T.

    2015-01-01

    NASA operations for handling cryogens in ground support equipment have not changed substantially in 50 years, despite major technology advances in the field of cryogenics. NASA loses approximately 50% of the hydrogen purchased because of a continuous heat leak into ground and flight vessels, transient chill down of warm cryogenic equipment, liquid bleeds, and vent losses. NASA Kennedy Space Center (KSC) needs to develop energy-efficient cryogenic ground systems to minimize propellant losses, simplify operations, and reduce cost associated with hydrogen usage. The GODU LH2 project has designed, assembled, and started testing of a prototype storage and distribution system for liquid hydrogen that represents an advanced end-to-end cryogenic propellant system for a ground launch complex. The project has multiple objectives including zero loss storage and transfer, liquefaction of gaseous hydrogen, and densification of liquid hydrogen. The system is unique because it uses an integrated refrigeration and storage system (IRAS) to control the state of the fluid. This paper will present and discuss the results of the initial phase of testing of the GODU LH2 system.

  3. Initial closed operation of the CELSS Test Facility Engineering Development Unit

    Science.gov (United States)

    Kliss, M.; Blackwell, C.; Zografos, A.; Drews, M.; MacElroy, R.; McKenna, R.; Heyenga, A. G.

    2003-01-01

    As part of the NASA Advanced Life Support Flight Program, a Controlled Ecological Life Support System (CELSS) Test Facility Engineering Development Unit has been constructed and is undergoing initial operational testing at NASA Ames Research Center. The Engineering Development Unit (EDU) is a tightly closed, stringently controlled, ground-based testbed which provides a broad range of environmental conditions under which a variety of CELSS higher plant crops can be grown. Although the EDU was developed primarily to provide near-term engineering data and a realistic determination of the subsystem and system requirements necessary for the fabrication of a comparable flight unit, the EDU has also provided a means to evaluate plant crop productivity and physiology under controlled conditions. This paper describes the initial closed operational testing of the EDU, with emphasis on the hardware performance capabilities. Measured performance data during a 28-day closed operation period are compared with the specified functional requirements, and an example of inferring crop growth parameters from the test data is presented. Plans for future science and technology testing are also discussed. Published by Elsevier Science Ltd on behalf of COSPAR.

  4. Association Between Direct-to-Consumer Advertising and Testosterone Testing and Initiation in the United States, 2009-2013.

    Science.gov (United States)

    Layton, J Bradley; Kim, Yoonsang; Alexander, G Caleb; Emery, Sherry L

    2017-03-21

    Testosterone initiation increased substantially in the United States from 2000 to 2013, especially among men without clear indications. Direct-to-consumer advertising (DTCA) also increased during this time. To investigate associations between televised DTCA and testosterone testing and initiation in the United States. Ecologic study conducted in designated market areas (DMAs) in the United States. Monthly testosterone advertising ratings were linked to DMA-level testosterone use data from 2009-2013 derived from commercial insurance claims. Associations between DTCA and testosterone testing, initiation, and initiation without recent baseline tests were estimated using Poisson generalized estimating equations. Monthly Nielsen ratings for testosterone DTCA in the 75 largest DMAs. (1) Rates of new serum testosterone testing; (2) rates of testosterone initiation (in-office injection, surgical implant, or pharmacy dispensing) for all testosterone products combined and for specific brands; and (3) rates of testosterone initiation without recent serum testosterone testing. Of 17 228 599 commercially insured men in the 75 DMAs, 1 007 990 (mean age, 49.6 [SD, 11.5] years) had new serum testosterone tests and 283 317 (mean age, 51.8 [SD, 11.3] years) initiated testosterone treatment. Advertising intensity varied by geographic region and time, with the highest intensity seen in the southeastern United States and with months ranging from no ad exposures to a mean of 13.6 exposures per household. Nonbranded advertisements were common prior to 2012, with branded advertisements becoming more common during and after 2012. Each household advertisement exposure was associated with a monthly increase in rates of new testosterone testing (rate ratio [RR], 1.006; 95% CI, 1.004-1.008), initiation (RR, 1.007; 95% CI, 1.004-1.010), and initiation without a recent test (RR, 1.008; 95% CI, 1.002-1.013). Mean absolute rate increases were 0.14 tests (95% CI, 0.09-0.19), 0.05 new

  5. 40 CFR 63.9620 - On which units and by what date must I conduct performance tests or other initial compliance...

    Science.gov (United States)

    2010-07-01

    ... units and by what date must I conduct performance tests or other initial compliance demonstrations? (a... similar emission units together and conduct an initial compliance test on one representative emission unit... meet the criteria in paragraph (f) of this section. If you decide to test representative emission units...

  6. The Initial Test Programme Features for the Advanced Korean NPPs (Shin–Kori NPP Units 3&4)

    International Nuclear Information System (INIS)

    Sul, Y.S.

    2015-01-01

    Korea has developed the Advanced Power Reactor 1400 (APR1400), an evolutionary pressurised water reactor and has obtained the standard design approval in 2002. As of 2014, eight nuclear power plants (NPPs) are in preparation for operation or under construction, four in Korea (SKN 3&4, SUN 1&2) and four in UAE (BNPP 1, 2, 3&4), and four NPPs are in planning in Korea (SKN 5&6, SUN 3&4). Especially, SKN Units 3&4 are the first construction NPPs for the APR1400 and are currently in the final stage to get Operating Licence (OL). The initial test programme for NPPs begins as systems and components are turned over to the startup organization and ends with completion of the Power Ascension Tests (PATs). For SKN Unit 3, the Pre-core Hot Functional Testing has been successfully completed and the initial fuel loading would proceed after getting OL. The SKN Unit 4 is preparing for the CHT (Cold Hydrostatic Test). The SKN 3&4 has many new and advanced design features and so has developed the test programmes to demonstrate that those advanced design features can be safely operated and the performance levels can be maintained in accordance with approved safety requirements. Among those test programs, the examples of test programs, newly introduced ones compared to the previous NPPs are as follows; – SIT (Safety Injection Tank) Blowdown Test with FD (Fluidic Device) – IRWST (In-Containment Refueling Water Storage Tank) In-Plant Test – POSRV (Pilot Operated Safety Relief Valve) Test – Low Power Physics Testing and PAT considering FOAK (First Of A Kind) unit – Safe Shutdown Test with DCS (Distrubuted Control System) Fail and CMF (Common Mode Failure) for Safety Instrumentation and Control System. (author)

  7. Will initiatives to promote hydroelectricity consumption be effective? Evidence from univariate and panel LM unit root tests with structural breaks

    International Nuclear Information System (INIS)

    Lean, Hooi Hooi; Smyth, Russell

    2014-01-01

    This paper examines whether initiatives to promote hydroelectricity consumption are likely to be effective by applying univariate and panel Lagrange Multiplier (LM) unit root tests to hydroelectricity consumption in 55 countries over the period 1965–2011. We find that for the panel, as well as about four-fifths of individual countries, that hydroelectricity consumption is stationary. This result implies that shocks to hydroelectricity consumption in most countries will only result in temporary deviations from the long-run growth path. An important consequence of this finding is that initiatives designed to have permanent positive effects on hydroelectricity consumption, such as large-scale dam construction, are unlikely to be effective in increasing the share of hydroelectricity, relative to consumption of fossil fuels. - Highlights: • Applies unit root tests to hydroelectricity consumption. • Hydroelectricity consumption is stationary. • Shocks to hydroelectricity consumption result in temporary deviations from the long-run growth path

  8. Planter unit test stand

    Science.gov (United States)

    A planter test stand was developed to evaluate individual row-crop metering units in early 2013. This test stand provided the ability to quantify actual seed metering in terms of population, seed spacing, skips, and multiples over a range of meter RPMs and vacuum pressures. Preliminary data has been...

  9. Development of crack growth and crack initiation test units for stress corrosion cracking examinations in high-temperature water environments under neutron irradiation (1) (Contract research)

    International Nuclear Information System (INIS)

    Izumo, Hironobu; Ishida, Takuya; Kawamata, Kazuo; Inoue, Shuichi; Ide, Hiroshi; Saito, Takashi; Ishitsuka, Etsuo; Chimi, Yasuhiro; Ise, Hideo; Miwa, Yukio; Ugachi, Hirokazu; Nakano, Junichi; Kaji, Yoshiyuki; Tsukada, Takashi

    2009-04-01

    To evaluate integrity of irradiation-assisted stress corrosion cracking (IASCC) on in-core structural materials used in light water reactors (LWRs), useful knowledge regarding IASCC has been obtained mainly by post-irradiation examinations (PIEs). In the core of commercial LWRs, however, the actual IASCC occurs under the effects of irradiation on both materials and high-temperature water environment. Therefore, it is necessary to confirm the suitability of the knowledge by PIE with comparison to IASCC behaviors during in-core SCC tests. Fundamental techniques for in-core crack growth and crack initiation tests have been developed already at the Japan Materials Testing Reactor (JMTR) of the Japan Atomic Energy Agency (JAEA). For the in-core crack growth test technique, to evaluate the effects of neutron irradiation on stainless steels irradiated to low neutron fluences, it is indispensable to develop new loading technique which is applicable to compact tension (CT) specimens with thickness of 0.5 inch (0.5T), from the viewpoint of validity based on the fracture mechanics. Based on the present technical investigation for the in-core loading technique, it is expected that a target load of 7.6 kN approximately can apply to a 0.5T-CT specimen by adopting a loading unit of a lever type instead of the previous uni-axial tension type. For the in-core crack initiation test technique, moreover, construction of a loading unit adopting linear variable differential transformers (LVDTs) has been investigated and technical issues have examined. (author)

  10. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2

    Science.gov (United States)

    Platt, R.

    1999-01-01

    This is the Performance Verification Report, Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). The specification establishes the requirements for the Comprehensive Performance Test (CPT) and Limited Performance Test (LPT) of the Advanced Microwave Sounding, Unit-A2 (AMSU-A2), referred to herein as the unit. The unit is defined on Drawing 1331200. 1.2 Test procedure sequence. The sequence in which the several phases of this test procedure shall take place is shown in Figure 1, but the sequence can be in any order.

  11. State nuclear initiatives in the United States

    International Nuclear Information System (INIS)

    Strauss, P.L.; Stoiber, C.R.

    1977-01-01

    The paper deals with State nuclear initiatives regarding the role of nuclear power in the energy future of the United States. The question of whether and under what circumstances nuclear facilities should be used to generate electricity was put to the popular vote in several States in 1976. Some general principles of Federal-State relations are discussed with specific reference to nuclear regulations. The initiative mechanism itself is described as well as its legal form and background. The parallel developments in the State and Federal legislative consideration of nuclear issues is reviewed and the suggested reasons for the defeat of the proposals in the seven States concerned are discussed. Finally, the author draws some conclusions on the effects of the 1976 initiatives on future decision-making in the US on energy policy in general and nuclear power in particular. (NEA) [fr

  12. The United Nations Basic Space Science Initiative

    Science.gov (United States)

    Haubold, Hans; Balogh, Werner

    2014-05-01

    The basic space science initiative was a long-term effort for the development of astronomy and space science through regional and international cooperation in this field on a worldwide basis, particularly in developing nations. Basic space science workshops were co-sponsored and co-organized by ESA, JAXA, and NASA. A series of workshops on basic space science was held from 1991 to 2004 (India 1991, Costa Rica and Colombia 1992, Nigeria 1993, Egypt 1994, Sri Lanka 1995, Germany 1996, Honduras 1997, Jordan 1999, France 2000, Mauritius 2001, Argentina 2002, and China 2004; http://neutrino.aquaphoenix.com/un-esa/) and addressed the status of astronomy in Asia and the Pacific, Latin America and the Caribbean, Africa, and Western Asia. Through the lead of the National Astronomical Observatory Japan, astronomical telescope facilities were inaugurated in seven developing nations and planetariums were established in twenty developing nations based on the donation of respective equipment by Japan.Pursuant to resolutions of the Committee on the Peaceful Uses of Outer Space of the United Nations (COPUOS) and its Scientific and Technical Subcommittee, since 2005, these workshops focused on the preparations for and the follow-ups to the International Heliophysical Year 2007 (UAE 2005, India 2006, Japan 2007, Bulgaria 2008, South Korea 2009; www.unoosa.org/oosa/SAP/bss/ihy2007/index.html). IHY's legacy is the current operation of 16 worldwide instrument arrays with more than 1000 instruments recording data on solar-terrestrial interaction from coronal mass ejections to variations of the total electron content in the ionosphere (http://iswisecretariat.org/). Instruments are provided to hosting institutions by entities of Armenia, Brazil, France, Israel, Japan, Switzerland, and the United States. Starting in 2010, the workshops focused on the International Space Weather Initiative (ISWI) as mandated in a three-year-work plan as part of the deliberations of COPUOS. Workshops on ISWI

  13. Initial startup and operations of Yonggwang Units 3 and 4

    International Nuclear Information System (INIS)

    Collier, T.J.; Chari, D.R.; Kiraly, F.

    1996-01-01

    A significant milestone in the nuclear power industry was achieved in 1995, when Yonggwang (YGN) Units 3 and 4 were accepted into in commercial operation by Korea Electric Power Corporation (KEPCO). YGN Unit 3 was accepted into commercial operation on March 31, 1995, the original date established during project initiation. YGN Unit 4 was accepted into operation on January 1, 1996, 3 months ahead of schedule. Each YGN unit produces approximately 1,050 Mwe and supplies approximately ten percent of the total electric power demand in the Republic of Korea (ROK). The overall plant efficiency is approximately 37% which is at least 1% higher than most nuclear units. Since achieving commercial operation, YGN Unit 3 has operated at essentially full power which has resulted in an annual performance rate in excess of 85%. YGN Unit 3 is the first of six pressurized water reactors which are currently under design and construction in the ROK and serves as the reference design for the Korean Standard Nuclear Power Plant program. Both YGN Units 3 and 4 include a System 800 Nuclear Steam Supply System (NSSS). The NSSS is rated at 2,815 Mwth and is the ABB-CE standard design. The design includes numerous advanced design features which enhance plant safety, performance and operability. A well executed startup test program was successfully completed on both units prior to commercial operation. A summary of the YGN NSSS design features, the startup test program and selected test results demonstrating the performance of those features are presented in this paper

  14. United States policy initiatives in promoting the RERTR program

    International Nuclear Information System (INIS)

    Huizenga, David G.

    1996-01-01

    The Reduced Enrichment for Research and Test Reactors (RERTR) program has been successful in furthering efforts to reduce and eventually eliminate highly enriched uranium (HEU) from international commerce. Three key policy initiatives are underway to further promote the RERTR program. The first initiative is implementation of a new nuclear weapons nonproliferation policy concerning foreign research reactor spent nuclear fuel. Under this policy, the United States will accept over the next 13 years research reactor spent fuel from 41 countries that have converted or plan to convert to use LEU fuels. The second initiative is to pursue cooperative efforts to expand the RERTR program to new regions of the globe, including Russia and China. The third initiative is to restart the advanced LEU fuels development program at the Argonne National Laboratory in order to increase the number of reactors that can convert to use LEU without significant detriment to their performance

  15. Test set for initial value problem solvers

    NARCIS (Netherlands)

    W.M. Lioen (Walter); J.J.B. de Swart (Jacques)

    1998-01-01

    textabstractThe CWI test set for IVP solvers presents a collection of Initial Value Problems to test solvers for implicit differential equations. This test set can both decrease the effort for the code developer to test his software in a reliable way, and cross the bridge between the application

  16. Political initiative needed in the United States

    International Nuclear Information System (INIS)

    Hollister, K.

    1979-01-01

    The financing of nuclear power stations in the United States is in trouble mainly because of the long lead times caused by licensing. It will again become feasible when legislation reduces the construction time to eight years or less. The overriding need to protect the dollar by reducing oil imports, will lead the US Government to embrace nuclear power openly. (U.K.)

  17. The United Nations Basic Space Science Initiative

    Science.gov (United States)

    Haubold, H. J.

    2006-08-01

    Pursuant to recommendations of the United Nations Conference on the Exploration and Peaceful Uses of Outer Space (UNISPACE III) and deliberations of the United Nations Committee on the Peaceful Uses of Outer Space (UNCOPUOS), annual UN/ European Space Agency workshops on basic space science have been held around the world since 1991. These workshops contribute to the development of astrophysics and space science, particularly in developing nations. Following a process of prioritization, the workshops identified the following elements as particularly important for international cooperation in the field: (i) operation of astronomical telescope facilities implementing TRIPOD, (ii) virtual observatories, (iii) astrophysical data systems, (iv) concurrent design capabilities for the development of international space missions, and (v) theoretical astrophysics such as applications of nonextensive statistical mechanics. Beginning in 2005, the workshops focus on preparations for the International Heliophysical Year 2007 (IHY2007). The workshops continue to facilitate the establishment of astronomical telescope facilities as pursued by Japan and the development of low-cost, ground-based, world-wide instrument arrays as lead by the IHY secretariat. Wamsteker, W., Albrecht, R. and Haubold, H.J.: Developing Basic Space Science World-Wide: A Decade of UN/ESA Workshops. Kluwer Academic Publishers, Dordrecht 2004. http://ihy2007.org http://www.unoosa.org/oosa/en/SAP/bss/ihy2007/index.html http://www.cbpf.br/GrupPesq/StatisticalPhys/biblio.htm

  18. Multi-Unit Initiating Event Analysis for a Single-Unit Internal Events Level 1 PSA

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong San; Park, Jin Hee; Lim, Ho Gon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The Fukushima nuclear accident in 2011 highlighted the importance of considering the risks from multi-unit accidents at a site. The ASME/ANS probabilistic risk assessment (PRA) standard also includes some requirements related to multi-unit aspects, one of which (IE-B5) is as follows: 'For multi-unit sites with shared systems, DO NOT SUBSUME multi-unit initiating events if they impact mitigation capability [1].' However, the existing single-unit PSA models do not explicitly consider multi-unit initiating events and hence systems shared by multiple units (e.g., alternate AC diesel generator) are fully credited for the single unit and ignores the need for the shared systems by other units at the same site [2]. This paper describes the results of the multi-unit initiating event (IE) analysis performed as a part of the at-power internal events Level 1 probabilistic safety assessment (PSA) for an OPR1000 single unit ('reference unit'). In this study, a multi-unit initiating event analysis for a single-unit PSA was performed, and using the results, dual-unit LOOP initiating event was added to the existing PSA model for the reference unit (OPR1000 type). Event trees were developed for dual-unit LOOP and dual-unit SBO which can be transferred from dual- unit LOOP. Moreover, CCF basic events for 5 diesel generators were modelled. In case of simultaneous SBO occurrences in both units, this study compared two different assumptions on the availability of the AAC D/G. As a result, when dual-unit LOOP initiating event was added to the existing single-unit PSA model, the total CDF increased by 1∼ 2% depending on the probability that the AAC D/G is available to a specific unit in case of simultaneous SBO in both units.

  19. An intersection test for panel unit roots

    NARCIS (Netherlands)

    Hanck, C.

    2013-01-01

    This article proposes a new panel unit root test based on Simes' ( 1986) classical intersection test. The test is robust to general patterns of cross-sectional dependence and yet is straightforward to implement, only requiring p-values of time series unit root tests of the series in the panel, and

  20. UNIT TRUST FUND'S INITIAL SERVICE CHARGE AND ITS DETERMINANTS

    Directory of Open Access Journals (Sweden)

    Nur Adiana Hiau Abdullah

    2006-01-01

    Full Text Available This paper examines the variables that might explain the initial service charge (ISC imposed on unit-holders of Malaysian unit trust funds in the year 1999. By using 39 openend unit trust funds, customer service and board structure variables are found to have asignificant effect in explaining the variations of ISC. Financial performance variables do not seem to have any influence on the level of ISC charged to the unit-holders. Our results also showed that funds which charged higher ISC do not necessarily provide higher returns to investors. Furthermore, there are unit trust funds that are having an initial service charge beyond the maximum 10% level required by the Securities Commissions or did not fulfil the independent directors requirement.

  1. Testing of the structural evaluation test unit

    International Nuclear Information System (INIS)

    Ammerman, D.J.; Bobbe, J.G.

    1995-01-01

    In the evaluation of the safety of radioactive material transportation it is important to consider the response of Type B packages to environments more severe than that prescribed by the hypothetical accident sequence in Title 10 Part 71 of the Code of Federal Regulations (NRC 1995). The impact event in this sequence is a 9-meter drop onto an essentially unyielding target, resulting in an impact velocity of 13.4 m/s. The behavior of 9 packages when subjected to impacts more severe than this is not well known. It is the purpose of this program to evaluate the structural response of a test package to these environments. Several types of structural response are considered. Of primary importance is the behavior of the package containment boundary, including the bolted closure and 0-rings. Other areas of concern are loss of shielding capability due to lead slump and the deceleration loading of package contents, that may cause damage to them. This type of information is essential for conducting accurate risk assessments on the transportation of radioactive materials. Currently very conservative estimates of the loss of package protection are used in these assessments. This paper will summarize the results of a regulatory impact test and three extra-regulatory impact tests on a sample package

  2. Eddy current tube testing unit

    International Nuclear Information System (INIS)

    Dufayet, J.P.; Duret, G.

    1975-01-01

    The unit described can check a wide variety of tubes in quick succession and its modular design gives it a high degree of versability. Suitably defined working conditions and specific fittings enable most of the faults encountered in the manufacture of a tube to be detected. By appropriate means of selection based on signal amplitude, phase and frequency analyses it is possible to adapt selection criteria to the seriousness of the different categories of defect [fr

  3. Automation of unit for leakage test

    OpenAIRE

    LYCHKOVSKAYA V.S.; TSYGANKOV A.S.; GRINBERG G.M.; STANOVOVA O.A.

    2015-01-01

    Federal state educational standard requirements for training of university students have been considered. Leakage test procedures for components of aerospace vehicles have been described. Automation procedures of existing laboratory leakage test units have been outlined.

  4. AREVA Logistics Business Unit Transportation Risk Management Initiative

    International Nuclear Information System (INIS)

    Anne, C.

    2009-01-01

    A safe, secure and reliable transportation organization is a key component for the success of the nuclear industry. With the forecasted increase of radioactive material transport flows in future and the changing environment, AREVA Logistic Business Unit (L-BU) must ensure that safety and security risks are minimized but also ensure of the chain supply for its various facilities (mines, conversion, enrichment, fuel manufacturing, reprocessing, etc). AREVA L-BU Unit is implementing a transportation risk management initiative for the radioactive shipments of the AREVA group across all the Business Unit involved in shipments of radioactive and nuclear materials. The paper will present the four main components of the risk management. (authors)

  5. Proposal for a United Nations Basic Space Technology Initiative

    Science.gov (United States)

    Balogh, Werner

    Putting space technology and its applications to work for sustainable economic and social development is the primary objective of the United Nations Programme on Space Applications, launched in 1971. A specific goal for achieving this objective is to establish a sustainable national space capacity. The traditional line of thinking has supported a logical progression from building capacity in basic space science, to using space applications and finally - possibly - to establishing indigenous space technology capabilities. The experience in some countries suggests that such a strict line of progression does not necessarily hold true and that priority given to the establishment of early indigenous space technology capabilities may contribute to promoting the operational use of space applications in support of sustainable economic and social development. Based on these findings and on the experiences with the United Nations Basic Space Science Initiative (UNBSSI) as well as on a series of United Nations/International Academy of Astronautics Workshops on Small Satellites in the Service of Developing Countries, the United Nations Office for Outer Space Affairs (UNOOSA) is considering the launch of a dedicated United Nations Basic Space Technology Initiative (UNBSTI). The initiative would aim to contribute to capacity building in basic space technology and could include, among other relevant fields, activities related to the space and ground segments of small satellites and their applications. It would also provide an international framework for enhancing cooperation between all interested actors, facilitate the exchange of information on best practices, and contribute to standardization efforts. It is expected that these activities would advance the operational use of space technology and its applications in an increasing number of space-using countries and emerging space nations. The paper reports on these initial considerations and on the potential value-adding role

  6. OPSAID Initial Design and Testing Report.

    Energy Technology Data Exchange (ETDEWEB)

    Hurd, Steven A.; Stamp, Jason Edwin [Sandia National Laboratories, Albuquerque, NM; Chavez, Adrian R. [Sandia National Laboratories, Albuquerque, NM

    2007-11-01

    and inherently secure PCS in the future. All activities are closely linked to industry outreach and advisory efforts.Generally speaking, the OPSAID project is focused on providing comprehensive security functionality to PCS that communicate using IP. This is done through creating an interoperable PCS security architecture and developing a reference implementation, which is tested extensively for performance and reliability.This report first provides background on the PCS security problem and OPSAID, followed by goals and objectives of the project. The report also includes an overview of the results, including the OPSAID architecture and testing activities, along with results from industry outreach activities. Conclusion and recommendation sections follow. Finally, a series of appendices provide more detailed information regarding architecture and testing activities.Summarizing the project results, the OPSAID architecture was defined, which includes modular security functionality and corresponding component modules. The reference implementation, which includes the collection of component modules, was tested extensively and proved to provide more than acceptable performance in a variety of test scenarios. The primary challenge in implementation and testing was correcting initial configuration errors.OPSAID industry outreach efforts were very successful. A small group of industry partners were extensively involved in both the design and testing of OPSAID. Conference presentations resulted in creating a larger group of potential industry partners.Based upon experience implementing and testing OPSAID, as well as through collecting industry feedback, the OPSAID project has done well and is well received. Recommendations for future work include further development of advanced functionality, refinement of interoperability guidance, additional laboratory and field testing, and industry outreach that includes PCS owner education. 4 5 --This page intentionally left blank --

  7. Practical unit testing with JUnit and Mockito

    CERN Document Server

    Kaczanowski, Tomek

    2013-01-01

    This book explains in detail how to implement unit tests using two very popular open source Java technologies: JUnit and Mockito. It presents a range of techniques necessary to write high quality unit tests - e.g. mocks, parametrized tests and matchers. It also discusses trade-offs related to the choices we have to make when dealing with some real-life code issues. The book stresses the importance of writing readable and maintainable unit tests, and puts a lot of stress on code quality. It shows how to achieve testable code and to eliminate common mistakes by following the Test Driven Development approach. Every topic discussed in the book is illustrated with code examples, and each chapter is accompanied by some exercises. By reading this book you will: Grasp the role and purpose of unit tests Write high-quality, readable and maintainable unit tests Learn how to use JUnit and Mockito (but also other useful tools) Avoid common pitfalls when writing unit tests Recognize bad unit tests, a...

  8. A Nonparametric Test for Seasonal Unit Roots

    OpenAIRE

    Kunst, Robert M.

    2009-01-01

    Abstract: We consider a nonparametric test for the null of seasonal unit roots in quarterly time series that builds on the RUR (records unit root) test by Aparicio, Escribano, and Sipols. We find that the test concept is more promising than a formalization of visual aids such as plots by quarter. In order to cope with the sensitivity of the original RUR test to autocorrelation under its null of a unit root, we suggest an augmentation step by autoregression. We present some evidence on the siz...

  9. Unit Testing for Command and Control Systems

    Science.gov (United States)

    Alexander, Joshua

    2018-01-01

    Unit tests were created to evaluate the functionality of a Data Generation and Publication tool for a command and control system. These unit tests are developed to constantly evaluate the tool and ensure it functions properly as the command and control system grows in size and scope. Unit tests are a crucial part of testing any software project and are especially instrumental in the development of a command and control system. They save resources, time and costs associated with testing, and catch issues before they become increasingly difficult and costly. The unit tests produced for the Data Generation and Publication tool to be used in a command and control system assure the users and stakeholders of its functionality and offer assurances which are vital in the launching of spacecraft safely.

  10. Initial waste package interaction tests: status report

    International Nuclear Information System (INIS)

    Shade, J.W.; Bradley, D.J.

    1980-12-01

    This report describes the results of some initial investigations of the effects of rock media on the release of simulated fission products from a sngle waste form, PNL reference glass 76-68. All tests assemblies contained a minicanister prepared by pouring molten, U-doped 76-68 glass into a 2-cm-dia stanless steel tube closed at one end. The tubes were cut to 2.5 to 7.5 cm in length to expose a flat glass surface rimmed by the canister wall. A cylindrical, whole rock pellet, cut from one of the rock materials used, was placed on the glass surface then both the canister and rock pellet were packed in the same type of rock media ground to about 75 μm to complete the package. Rock materials used were a quartz monzonite basalt and bedded salt. These packages were run from 4 to 6 weeks in either 125 ml digestion bombs or 850 ml autoclaves capable of direct solution sampling, at either 250 or 150 0 C. Digestion bomb pressures were the vapor pressure of water, 600 psig at 250 0 C, and the autoclaves were pressurized at 2000 psig with an argon overpressure. In general, the solution chemistry of these initial package tests suggests that the rock media is the dominant controlling factor and that rock-water interaction may be similar to that observed in some geothermal areas. In no case was uranium observed in solution above 15 ppB. The observed leach rates of U glass not in contact with potential sinks (rock surfaces and alteration products) have been observed to be considerably higher. Thus the use of leach rates and U concentrations observed from binary leach experiments (waste-form water only) to ascertain long-term environmental consequences appear to be quite conservative compared to actual U release in the waste package experiments. Further evaluation, however, of fission product transport behavior and the role of alteration phases as fission product sinks is required

  11. The United States initiative for international radioactive source management (ISRM)

    International Nuclear Information System (INIS)

    Naraine, N.; Karhnak, J.

    1999-01-01

    The United States takes seriously the potential problems from uncontrolled radioactive sources. To address these problems, the United States Department of State is leading the development of an initiative for International Radioactive Source Management (ISRM). The Department of State, through a number of Federal and state agencies, regulatory bodies and private industry, will endeavor to provide coordinated support to the international community, particularly through IAEA, to assist in the development and implementation of risk-based clearance levels to support import/export of radioactive contaminated metals and the tracking, management, identification, remediation, and disposition of 'lost sources' entering nation states and targeted industries. The United States believes that the international control of radioactive sources is critical in avoiding wide-spread contamination of the world metal supply. Thus the initiative has four objectives: (1) Protect sources from becoming lost (Tracking management); (2) Identify primary locations where sources have been lost (Stop future losses); (3) Locate lost sources (monitor and retrieve); and (4) Educate and train (deploy knowledge and technology). A number of efforts already underway in the United States support the overall initiative. The EPA has provided a grant to the Conference of Radiation Program Control Directors (CRCPD) to develop a nation-wide program for the disposition of orphaned radioactive sources. This program now has internet visibility and a toll-free telephone number to call for assistance in the disposal of sources. The Nuclear Regulatory Commission (NRC), the Department of Energy (DOE), and other government agencies as well as private companies are assisting CRCPD in this program. The NRC has begun a program to improve control of radioactive sources in the United States, and also intends to promulgate a regulation defining conditions for the release of materials from licensed facilities. The DOE is

  12. Improving Size and Power in Unit Root Testing

    DEFF Research Database (Denmark)

    Haldrup, Niels; Jansson, Michael

    A frequent criticism of unit root tests concerns the poor power and size properties that many of such testsexhibit. However, the past decade or so intensive research has been conducted to alleviate these problems and great advances have been made. The present paper provides a selective survey...... of recent contributions to improve upon both size and power of unit root tests and in so doing the approach of using rigorous statistical optimality criteria in the development of such tests is stressed. In addition to presenting tests where improved size can be achieved by modifying the standard Dickey......-Fuller class of tests, the paper presents theory of optimal testing and the construction of power envelopes for unit root tests underdifferent conditions allowing for serial correlation, deterministic components, assumptions regarding the initial condition, non-Gaussian errors, and the use of covariates....

  13. Opinion poll tests support for democratic initiatives

    International Nuclear Information System (INIS)

    Burkhart, L.A.

    1993-01-01

    A national opinion poll designed to test public support for a position paper on energy policy for the Clinton Administration and the new Congress, was released February 9 at a Capitol Hill press conference sponsored by the Environmental and Energy Study Institute. The poll, conducted by the Democratic polling firm Greenberg/Lake and Republican pollster Lance Tarrance, found voters want energy efficiency, conservation, and renewable energy as top priorities for the nation's energy policy. It also found voters are willing to seek these policies with tough regulation, tax incentives, and their own behavior. Also, voters appear to support taxes on pollution and energy use, whether the income is used to decrease taxes on personal income, or to reduce the deficit. However, voters oppose gas taxes and are divided on taxes for fossil fuels. Support for energy taxes increases if revenues generated by them are dedicated to deficit reduction. The poll also revealed: the public's desire for less emphasis on polluting sources of energy such as oil and coal; low levels of support for nuclear power; support for government initiatives to increase the fuel efficiency of consumer goods such as appliances and automobiles; opposition to a substantial increase in the gasoline tax; and support for green taxes on polluting sources of energy use at the same time policy makers remove federal tax subsidies on fuels that pollute

  14. Electronic cigarette initiation among minority youth in the United States.

    Science.gov (United States)

    Hammig, Bart; Daniel-Dobbs, Page; Blunt-Vinti, Heather

    2017-05-01

    Electronic cigarettes (e-cigarette) use among youth is a pressing public health issue, with prevalence of use surpassing that of tobacco cigarettes. While research concerning e-cigarettes has proliferated in recent years, there is a dearth of information regarding those whose first exposure to tobacco products was an e-cigarette. To examine factors associated with e-cigarette initiation among minority youth in the United States. Data on minority students in middle and high schools in the United States derived from the 2014 National Youth Tobacco Survey (NYTS) were sampled (weighted N = 27,294,454). We examined e-cigarette initiation among minority youth using logistic regression models to identify related factors. In 2014, 736,158 minority youth were e-cigarette initiators. Odds of e-cigarette initiation was highest among Hispanic youth [adjusted odds ratio (AOR) = 2.70; 95% confidence interval (CI) = 1.60-4.56]. Exposure to e-cigarette advertising (AOR = 1.64; 95% CI = 1.07-2.50), perceptions of little to no harm (AOR = 7.08; 95% CI = 4.03-12.46), and believing e-cigarettes were less addictive than tobacco (AOR = 2.15; 95% CI = 1.52-3.02) were associated with e-cigarette initiation. Odds of initiating e-cigarette use was highest among Hispanic youth. Among minority youth, e-cigarette initiation was associated with perceptions of harm and addiction potential, as well as exposure to e-cigarette advertising. Therefore, prevention efforts targeting minority youth who are at risk of becoming e-cigarette initiators may benefit by incorporating these factors into prevention campaigns.

  15. Initial field testing definition of subsurface sealing and backfilling tests in unsaturated tuff

    International Nuclear Information System (INIS)

    Fernandez, J.A.; Case, J.B.; Tyburski, J.R.

    1993-05-01

    This report contains an initial definition of the field tests proposed for the Yucca Mountain Project repository sealing program. The tests are intended to resolve various performance and emplacement concerns. Examples of concerns to be addressed include achieving selected hydrologic and structural requirements for seals, removing portions of the shaft liner, excavating keyways, emplacing cementitious and earthen seals, reducing the impact of fines on the hydraulic conductivity of fractures, efficient grouting of fracture zones, sealing of exploratory boreholes, and controlling the flow of water by using engineered designs. Ten discrete tests are proposed to address these and other concerns. These tests are divided into two groups: Seal component tests and performance confirmation tests. The seal component tests are thorough small-scale in situ tests, the intermediate-scale borehole seal tests, the fracture grouting tests, the surface backfill tests, and the grouted rock mass tests. The seal system tests are the seepage control tests, the backfill tests, the bulkhead test in the Calico Hills unit, the large-scale shaft seal and shaft fill tests, and the remote borehole sealing tests. The tests are proposed to be performed in six discrete areas, including welded and non-welded environments, primarily located outside the potential repository area. The final selection of sealing tests will depend on the nature of the geologic and hydrologic conditions encountered during the development of the Exploratory Studies Facility and detailed numerical analyses. Tests are likely to be performed both before and after License Application

  16. COTRANSA simulation of Chinshan unit one generator load rejection test

    International Nuclear Information System (INIS)

    Wu, C.H.

    1984-01-01

    A simulation of the plant behavior during a BWR generator load rejection transient using Exxon Nuclear Company's COTRANSA code is presented in this paper. The results are compared to measurements obtained by Taiwan Power Company during a generator load rejection transient, initiated at full power condition, which was one of the Chinshan Unit 1 initial cycle startup tests. Good agreement between the COTRANSA predicted and the measured values, indicates that the COTRANSA code can simulate this transient satisfactorily

  17. Integrated corridor management initiative : demonstration phase evaluation, San Diego air quality test plan.

    Science.gov (United States)

    2012-08-01

    This report presents the test plan for conducting the Air Quality Analysis for the United States Department of Transportation (U.S. DOT) evaluation of the San Diego Integrated Corridor Management (ICM) Initiative Demonstration. The ICM projects being...

  18. Integrated corridor management initiative : demonstration phase evaluation, Dallas air quality test plan.

    Science.gov (United States)

    2012-08-01

    This report presents the test plan for conducting the Air Quality Analysis for the United States : Department of Transportation (U.S. DOT) evaluation of the Dallas U.S. 75 Integrated Corridor : Management (ICM) Initiative Demonstration. The ICM proje...

  19. Integrated corridor management initiative : demonstration phase evaluation - Dallas technical capability analysis test plan.

    Science.gov (United States)

    This report presents the test plan for conducting the Technical Capability Analysis for the United States : Department of Transportation (U.S. DOT) evaluation of the Dallas U.S. 75 Integrated Corridor : Management (ICM) Initiative Demonstration. The ...

  20. Integrated corridor management initiative : demonstration phase evaluation, San Diego technical capability analysis test plan.

    Science.gov (United States)

    2012-08-01

    This report presents the test plan for conducting the Technical Capability Analysis for the United States Department of Transportation (U.S. DOT) evaluation of the San Diego Integrated Corridor Management (ICM) Initiative Demonstration. The ICM proje...

  1. 29 CFR 1919.71 - Unit proof test and examination of cranes.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Unit proof test and examination of cranes. 1919.71 Section... § 1919.71 Unit proof test and examination of cranes. (a) Unit proof tests of cranes shall be carried out at the following times: (1) In the cases of new cranes, before initial use and every 4 years...

  2. Initial Burn Pan (JMTF) Testing Results

    Science.gov (United States)

    2016-03-01

    burn pan and one located high on the Ex-USS Shadwell. There were also a number of GoPro cameras (3-4) that were positioned to observe specific...locations around the test area. A remote control drone equipped with a GoPro camera was also used to video the third test. All recorded video and still

  3. Initiated Testing for HIV in Macha

    African Journals Online (AJOL)

    Esem

    In-depth interviews were translated and transcribed into computer ... Results: A total of 809 respondents and 12 (twelve) key .... of persons in the rural areas have no access to media. .... testing outweigh the social implications were more likely.

  4. CIT photoheliograph functional verification unit test program

    Science.gov (United States)

    1973-01-01

    Tests of the 2/3-meter photoheliograph functional verification unit FVU were performed with the FVU installed in its Big Bear Solar Observatory vacuum chamber. Interferometric tests were run both in Newtonian (f/3.85) and Gregorian (f/50) configurations. Tests were run in both configurations with optical axis horizontal, vertical, and at 45 deg to attempt to determine any gravity effects on the system. Gravity effects, if present, were masked by scatter in the data associated with the system wavefront error of 0.16 lambda rms ( = 6328A) apparently due to problems in the primary mirror. Tests showed that the redesigned secondary mirror assembly works well.

  5. Experiment data report for Test RIA 1-2 (Reactivity Initiated Accident Test Series)

    International Nuclear Information System (INIS)

    Zimmermann, C.L.; White, C.E.; Evans, R.P.

    1979-06-01

    Recorded test data are presented for the second of six planned tests in the Reactivity Initiated Accident (RIA) Test Series I, Test RIA 1-2. This test, conducted at the Power Burst Facility, had the following objectives: (1) characterize the response of preirradiated fuel rods during an RIA event conducted at boiling water reactor hot-startup conditions; and (2) evaluate the effect of rod internal pressure on preirradiated fuel rod response during an RIA event. The data from Test RIA 1-2 are graphed in engineering units and have been appraised for quality and validity. These uninterpreted data are presented for use in the nuclear fuel behavior research field before detailed analysis and interpretation have been completed

  6. Characteristic test of initial HTTR core

    International Nuclear Information System (INIS)

    Nojiri, Naoki; Shimakawa, Satoshi; Fujimoto, Nozomu; Goto, Minoru

    2004-01-01

    This paper describes the results of core physics test in start-up and power-up of the HTTR. The tests were conducted in order to ensure performance and safety of the high temperature gas cooled reactor, and was carried out to measure the critical approach, the excess reactivity, the shutdown margin, the control rod worth, the reactivity coefficient, the neutron flux distribution and the power distribution. The expected core performance and the required reactor safety characteristics were verified from the results of measurements and calculations

  7. Startup physics tests at Temelin NPP, Unit 1

    International Nuclear Information System (INIS)

    Sedlacek, M.; Minarcin, M.; Toth, L.; Elko, M.; Hascik, R.

    2002-01-01

    The objective, scope and proceedings of the physics tests of Temelin NPP, Unit 1 physical commissioning are given in this paper. Furthermore, some results of selected physics tests are presented: reactor initial criticality test, determination of reactor power range for physics testing, measurement of control rod cluster assembly group no. 10 reactivity worth in case of limitation system LS(a) actuation, control rod cluster assembly system reactivity worth measurement with single rod cluster assembly of greatest reactivity worth stuck in fully withdrawn position, measurement of differential reactivity worth of control rod cluster assembly group no. 9, boron 'endpoint' determination and measurement of power reactivity coefficient (Authors)

  8. Tests of an experimental slash ignition unit

    Science.gov (United States)

    James L. Murphy; Harry E. Schimke

    1965-01-01

    A prototype ignition package containing an incendiary powder and designed for slash and brush burning jobs showed some promise, but the unit tested was not superior to such conventional devices as fusees, diesel backpack type flamethrowers, Very pistols, and drip torches.

  9. Some pitfalls in unit root testing

    NARCIS (Netherlands)

    Bakker, B.B.; Koning, Ruud H.

    1991-01-01

    Testing for unit roots is now common practice for economists. The most popular procedure is the approach developed by Dickey and Fuller (1979, 1981), which only requires running appropriately specified regressions. However, application of the Dickey-Fuller procedure requires that the disturbance

  10. Testing for Unit Roots in Market Shares

    NARCIS (Netherlands)

    Franses, P.H.B.F.; Srinivasan, S.; Boswijk, H.P.

    2001-01-01

    A unique characteristic of marketing data sets is the logical consistency requirement in market share models that market shares are bounded by 0 and 1, and they sum to unity. To take account of this logical consistency requirement, we propose to test for unit roots in individual market share series

  11. Initial proto II pulsed power tests

    International Nuclear Information System (INIS)

    Johnson, D.L.

    1976-01-01

    The Proto II electron beam accelerator is being developed by Sandia Laboratories to study engineering and physics aspects of electron beam pellet fusion. Currently the Marx generator-water capacitor portion of Proto II is undergoing high voltage testing and timing measurements. Eight 112 kJ Marx generators form the primary energy storage system. Each Marx generator pulse charges two parallel 7.5 nF water capacitors to 3 MV. The water capacitors act as intermediate energy storage elements and will transfer their energy to the water insulated pulse-forming lines in 250 ns by means of eight SF 6 gas insulated, trigatron switches. Test data and design considerations of the trigger systems, Marx generators, water capacitors, and trigatron switches are presented

  12. The missing link? Testing a schema account of unitization.

    Science.gov (United States)

    Tibon, Roni; Greve, Andrea; Henson, Richard

    2018-05-09

    Unitization refers to the creation of a new unit from previously distinct items. The concept of unitization has been used to explain how novel pairings between items can be remembered without requiring recollection, by virtue of new, item-like representations that enable familiarity-based retrieval. We tested an alternative account of unitization - a schema account - which suggests that associations between items can be rapidly assimilated into a schema. We used a common operationalization of "unitization" as the difference between two unrelated words being linked by a definition, relative to two words being linked by a sentence, during an initial study phase. During the following relearning phase, a studied word was re-paired with a new word, either related or unrelated to the original associate from study. In a final test phase, memory for the relearned associations was tested. We hypothesized that, if unitized representations act like schemas, then we would observe some generalization to related words, such that memory would be better in the definition than sentence condition for related words, but not for unrelated words. Contrary to the schema hypothesis, evidence favored the null hypothesis of no difference between definition and sentence conditions for related words (Experiment 1), even when each cue was associated with multiple associates, indicating that the associations can be generalized (Experiment 2), or when the schematic information was explicitly re-activated during Relearning (Experiment 3). These results suggest that unitized associations do not generalize to accommodate new information, and therefore provide evidence against the schema account.

  13. Ductile crack initiation in the Charpy V-notch test

    International Nuclear Information System (INIS)

    Server, W.L.; Norris, D.M. Jr.; Prado, M.E.

    1978-01-01

    Initiation and growth of a crack in the Charpy V-notch test was investigated by performing both static and impact controlled deflection tests. Test specimens were deformed to various deflections, heat-tinted to mark crack extension and broken apart at low temperature to allow extension measurements. Measurement of the crack extension provided an estimate of crack initiation as defined by different criteria. Crack initiation starts well before maximum load, and is dependent on the definition of ''initiation''. Using a definition of first micro-initiation away from the ductile blunting, computer model predictions agreed favorably with the experimental results

  14. RESULTS OF INITIAL AMMONIA OXIDATION TESTING

    Energy Technology Data Exchange (ETDEWEB)

    Nash, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Fowley, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-12-30

    This memo presents an experimental survey of aqueous phase chemical processes to remove aqueous ammonia from waste process streams. Ammonia is generated in both the current Hanford waste flowsheet and in future waste processing. Much ammonia will be generated in the Low Activity Waste (LAW) melters.i Testing with simulants in glass melters at Catholic University has demonstrated the significant ammonia production.ii The primary reaction there is the reducing action of sugar on nitrate in the melter cold cap. Ammonia has been found to be a problem in secondary waste stabilization. Ammonia vapors are noxious and destruction of ammonia could reduce hazards to waste treatment process personnel. It is easily evolved especially when ammonia-bearing solutions are adjusted to high pH.

  15. Graphics processing units accelerated semiclassical initial value representation molecular dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Tamascelli, Dario; Dambrosio, Francesco Saverio [Dipartimento di Fisica, Università degli Studi di Milano, via Celoria 16, 20133 Milano (Italy); Conte, Riccardo [Department of Chemistry and Cherry L. Emerson Center for Scientific Computation, Emory University, Atlanta, Georgia 30322 (United States); Ceotto, Michele, E-mail: michele.ceotto@unimi.it [Dipartimento di Chimica, Università degli Studi di Milano, via Golgi 19, 20133 Milano (Italy)

    2014-05-07

    This paper presents a Graphics Processing Units (GPUs) implementation of the Semiclassical Initial Value Representation (SC-IVR) propagator for vibrational molecular spectroscopy calculations. The time-averaging formulation of the SC-IVR for power spectrum calculations is employed. Details about the GPU implementation of the semiclassical code are provided. Four molecules with an increasing number of atoms are considered and the GPU-calculated vibrational frequencies perfectly match the benchmark values. The computational time scaling of two GPUs (NVIDIA Tesla C2075 and Kepler K20), respectively, versus two CPUs (Intel Core i5 and Intel Xeon E5-2687W) and the critical issues related to the GPU implementation are discussed. The resulting reduction in computational time and power consumption is significant and semiclassical GPU calculations are shown to be environment friendly.

  16. SCC Initiation Testing of Alloy 600 in High Temperature Water

    Science.gov (United States)

    Etien, Robert A.; Richey, Edward; Morton, David S.; Eager, Julie

    Stress corrosion cracking (SCC) initiation tests have been conducted on Alloy 600 at temperatures from 304 to 367°C. Tests were conducted with in-situ monitored smooth tensile specimens under a constant load in hydrogenated environments. A reversing direct current electric potential drop (EPD) system was used for all of the tests to detect SCC initiation. Tests were conducted to examine the effects of stress (and strain), coolant hydrogen, and temperature on SCC initiation time. The thermal activation energy of SCC initiation was measured as 103 ± 18 kJ/mol in hydrogenated water, which is similar to the thermal activation energy for SCC growth. Results suggest that the fundamental mechanical parameter which controls SCC initiation is plastic strain not stress. SCC initiation was shown to have a different sensitivity than SCC growth to dissolved hydrogen level. Specifically, SCC initiation time appears to be relatively insensitive to hydrogen level in the nickel stability region.

  17. Digital tape unit test facility software

    Science.gov (United States)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  18. High Power Alternator Test Unit (ATU) Electrical System Test

    Science.gov (United States)

    Birchenough, Arthur; Hervol, David

    2007-01-01

    The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, OH was used to simulate the operating conditions and evaluate the performance of the ATU and it s interaction with various LPSF components in accordance with the JIMO AC Power System Requirements. The testing was carried out at the breadboard development level. Results of these tests will be used for the development and validation of analytical models for performance and lifetime prediction.

  19. Development and Initial Testing of the Tiltrotor Test Rig

    Science.gov (United States)

    Acree, C. W., Jr.; Sheikman, A. L.

    2018-01-01

    The NASA Tiltrotor Test Rig (TTR) is a new, large-scale proprotor test system, developed jointly with the U.S. Army and Air Force, to develop a new, large-scale proprotor test system for the National Full-Scale Aerodynamics Complex (NFAC). The TTR is designed to test advanced proprotors up to 26 feet in diameter at speeds up to 300 knots, and even larger rotors at lower airspeeds. This combination of size and speed is unprecedented and is necessary for research into 21st-century tiltrotors and other advanced rotorcraft concepts. The TTR will provide critical data for validation of state-of-the-art design and analysis tools.

  20. Eyeball test using abdominal ultrasound unit

    International Nuclear Information System (INIS)

    Choi, Chun Kyu; Lee, Yong Woo; Cheung, Hwan

    1984-01-01

    Ultrasonography is a wide diagnostic use for its desirable quality that it causes no radiation hazard to the patient and allows to test him without causing pains, while affording much valued diagnostic information. Since Mundt reported in 1955 that Ultrasonography can be used for testing the eyeball, it has widely been used for clinical purpose, but in Korea many difficulties are being exist in the sonographic evaluation of the eyeball due to storage of the exclusive Ultrasound units for eyeball diagnosis. This treatise describes eyeball test methods along with clinical instances observed by a compound scanner for abdomen scan mounted with an eyeball transducer of a frequency as high as 5 to 7.5MHz and using water bag

  1. Test Report Emission Test Program EPA Information Collection Request for Delayed Coking Units 736 Coker Unit

    Science.gov (United States)

    ARI Environmental, Inc. (ARI) was retained by Houston Refining LP (HRO) to conduct an emission test program at their refinery located in Houston, Texas. The testing was conducted on on the 736 Delayed Coking Unit (DCU) in response to EPA's ICR.

  2. A prototype tap test imaging system: Initial field test results

    Science.gov (United States)

    Peters, J. J.; Barnard, D. J.; Hudelson, N. A.; Simpson, T. S.; Hsu, D. K.

    2000-05-01

    This paper describes a simple, field-worthy tap test imaging system that gives quantitative information about the size, shape, and severity of defects and damages. The system consists of an accelerometer, electronic circuits for conditioning the signal and measuring the impact duration, a laptop PC and data acquisition and processing software. The images are generated manually by tapping on a grid printed on a plastic sheet laid over the part's surface. A mechanized scanner is currently under development. The prototype has produced images for a variety of aircraft composite and metal honeycomb structures containing flaws, damages, and repairs. Images of the local contact stiffness, deduced from the impact duration using a spring model, revealed quantitatively the stiffness reduction due to flaws and damages, as well as the stiffness enhancement due to substructures. The system has been field tested on commercial and military aircraft as well as rotor blades and engine decks on helicopters. Field test results will be shown and the operation of the system will be demonstrated.—This material is based upon work supported by the Federal Aviation Administration under Contract #DTFA03-98-D-00008, Delivery Order No. IA016 and performed at Iowa State University's Center for NDE as part of the Center for Aviation Systems Reliability program.

  3. Unit testing, model validation, and biological simulation.

    Science.gov (United States)

    Sarma, Gopal P; Jacobs, Travis W; Watts, Mark D; Ghayoomie, S Vahid; Larson, Stephen D; Gerkin, Richard C

    2016-01-01

    The growth of the software industry has gone hand in hand with the development of tools and cultural practices for ensuring the reliability of complex pieces of software. These tools and practices are now acknowledged to be essential to the management of modern software. As computational models and methods have become increasingly common in the biological sciences, it is important to examine how these practices can accelerate biological software development and improve research quality. In this article, we give a focused case study of our experience with the practices of unit testing and test-driven development in OpenWorm, an open-science project aimed at modeling Caenorhabditis elegans. We identify and discuss the challenges of incorporating test-driven development into a heterogeneous, data-driven project, as well as the role of model validation tests, a category of tests unique to software which expresses scientific models.

  4. Radioactive Acid Digestion Test Unit (RADTU), 1980

    International Nuclear Information System (INIS)

    Allen, C.R.

    1980-01-01

    The Radioactive Acid Digestion Test Unit (RADTU) was constructed at the Hanford Site, Richland, WA to demonstrate application of the acid digestion process for treating combustible transuranic wastes and scrap materials. Using its original tray digester vessel, RADTU recently completed a six-month campaign of processing potentially contaminated non-glovebox wastes from a Hanford plutonium facility. During the campaign, 2100 kg of largely cellulosic wastes were processed at an average sustained processing rate of 3 kg/h (limited by the acid-waste contact and the water boiloff rate from the acid feeds). On-line operating efficiency was nearly 50%, averaged over 12 hours/day, for five days/week. After shutdown, a new annular high-rate digester was installed for testing that demonstrated a sustained capacity of 8 kg/h to 10 kg/h with greatly improved contact between the digestion acid and the waste. The new unit began processing low-level waste from Hanford's z-Plant during June 1980. Plutonium levels in the waste processed will be increased gradually as operating experience has been gained. Processing recoverable scrap is expected to begin in the last quarter of CY 1980

  5. Aquifer test plan for the 100-HR-3 Operable Unit

    International Nuclear Information System (INIS)

    Swanson, L.C.; Hartman, M.J.

    1994-01-01

    This test plan directs hydrologic testing activities planned at three existing Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) wells in the 100-HR-3 Operable Unit of the Hanford Site. Three additional wells will be installed near these existing wells and used as additional testing arid observation points during the field activities. Figure 1 shows the locations of the three test sites. A primary objective of the testing program is to provide more detailed hydraulic characterization information for the unconfined aquifer and targeted test sites than provided by the initial reconnaissance-level slug testing of Vukelich. A second objective is to evaluate the applicability of slug interference and dipole flow tests for detailed hydraulic characterization in an unconfined aquifer. This aquifer testing program will also be useful for substantiating hydraulic conductivities reported from previous slug tests and evaluating the effects of filter pack volume/configuration on slug test data. Vukelich recommended additional testing to address the latter two issues

  6. Mixed-Initiative Control of Autonomous Unmanned Units Under Uncertainty

    National Research Council Canada - National Science Library

    Thrun, Sebvastian; Gordon, Geoffrey; Burstein, Mark; Diller, David; Fox, Dieter

    2006-01-01

    .... We developed this control model using Partially Observable Markov Decision Processes. The mixed-initiative interactions enabled users to describe constraints at multiple levels of the planning hierarchy...

  7. A procedure for empirical initialization of adaptive testing algorithms

    NARCIS (Netherlands)

    van der Linden, Willem J.

    1997-01-01

    In constrained adaptive testing, the numbers of constraints needed to control the content of the tests can easily run into the hundreds. Proper initialization of the algorithm becomes a requirement because the presence of large numbers of constraints slows down the convergence of the ability

  8. The digital ultrasonic test unit for automatic equipment

    International Nuclear Information System (INIS)

    Hiraoka, T.; Matsuyama, H.

    1976-01-01

    The operations and features of the ultrasonic test unit used and the digital data processing techniques employed are described. This unit is used for a few hundred multi-channel automatic ultrasonic test equipment

  9. 29 CFR 1919.30 - Examinations subsequent to unit tests.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Examinations subsequent to unit tests. 1919.30 Section 1919... Treatment; Competent Persons § 1919.30 Examinations subsequent to unit tests. (a) After satisfactory completion of the unit proof load tests required by §§ 1919.27 and 1919.28, the cargo gear and all component...

  10. Hanford tank initiative test facility site selection study

    International Nuclear Information System (INIS)

    Staehr, T.W.

    1997-01-01

    The Hanford Tanks Initiative (HTI) project is developing equipment for the removal of hard heel waste from the Hanford Site underground single-shell waste storage tanks. The HTI equipment will initially be installed in the 241-C-106 tank where its operation will be demonstrated. This study evaluates existing Hanford Site facilities and other sites for functional testing of the HTI equipment before it is installed into the 241-C-106 tank

  11. Test report: Electron-proton spectrometer qualification test unit, qualification test

    Science.gov (United States)

    Vincent, D. L.

    1972-01-01

    Qualification tests of the electron-proton spectrometer test unit are presented. The tests conducted were: (1) functional, (2) thermal/vacuum, (3) electromagnetic interference, (4) acoustic, (5) shock, (6) vibration, and (7) humidity. Results of each type of test are presented in the form of data sheets.

  12. The initial criticality and nuclear commissioning test program at HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choong-Sung; Seo, Chul-Gyo; Jun, Byung-Jin [Korea Atomic Energy Research Institute, Dukjin-Dong 150, Yusung-Ku, Taejon, 305-353 (Korea, Republic of)

    1995-07-01

    The construction of the Korea Multipurpose Research Reactor - HANARO of 3MW, developed by Korea Atomic Energy Research Institute, was completed at the beginning of this year. The first fuel loading began on February 2 1995, and initial criticality was achieved on February 8, when the core had four 18-element assemblies and thirteen 36-element assemblies. The critical control rod position was 600.8 mm which represents excess reactivity of 0.71 $. Currently the nuclear commissioning test is on going under the zero power range. This paper describes the initial criticality approach of the HANARO, and its nuclear commissioning test program. (author)

  13. Detection of ductile crack initiation by acoustic emission testing

    International Nuclear Information System (INIS)

    Richter, H.; Boehmert, J.; Viehrig, H.W.

    1998-08-01

    A Charpy impact test equipment is described permitting simultaneous measurement of impact force, crack tip opening, acoustic emissions and magnetic emissions. The core of the equipment is an inverted pendulum ram impact testing machine and the tests have been performed with laterally notched, pre-fatigue ISO-V specimens made of steels of various strength and toughness properties. The tests are intended to ascertain whether the acoustic emission method is suitable for detecting steady crack initiation in highly ductile steels. (orig./CB) [de

  14. Initial approach to hypertension in the hemodynamics unit: review article

    Directory of Open Access Journals (Sweden)

    Gustavo Teixeira Fulton Schimit

    2013-06-01

    Full Text Available Correct identification and early management of hypertensive disorders should be a part of the therapeutic repertoire of every professional working in hemodynamics units. Based on recent publications, this study aims to propose a practical approach to the identification and early management of these disorders in this type of service.

  15. Digital preservation initiatives in the United States: a summary

    OpenAIRE

    Marcum, Deanna

    2003-01-01

    General presentation on how digital preservation issues are being faced in the United States of America. Special reference to the National Digital Information Infrastructure and Preservation Program, that is found at the Library of Congress, and aims to implement a national strategy for the long-term preservation of digital content.

  16. Dynamic Testing of Signal Transduction Deregulation During Breast Cancer Initiation

    Science.gov (United States)

    2012-07-01

    Std. Z39.18 Victoria Seewaldt, M.D. Dynamic Testing of Signal Transduction Deregulation During Breast Cancer Initiation Duke University Durham...attomole- zeptomole range. Internal dilution curves insure a high-dynamic calibration range. DU -26 8L DU -26 6L DU -29 5R DU -22 9.2 L DU...3: Nanobiosensor technology is translated to test for pathway deregulation in RPFNA cytology obtained from 10 high-risk women with cytological

  17. Initial field testing definition of subsurface sealing and backfilling tests in unsaturated tuff; Yucca Mountain Site Characterization Project

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, J.A. [Sandia National Labs., Albuquerque, NM (United States); Case, J.B.; Tyburski, J.R. [I. T. Corp., Albuquerque, NM (United States)

    1993-05-01

    This report contains an initial definition of the field tests proposed for the Yucca Mountain Project repository sealing program. The tests are intended to resolve various performance and emplacement concerns. Examples of concerns to be addressed include achieving selected hydrologic and structural requirements for seals, removing portions of the shaft liner, excavating keyways, emplacing cementitious and earthen seals, reducing the impact of fines on the hydraulic conductivity of fractures, efficient grouting of fracture zones, sealing of exploratory boreholes, and controlling the flow of water by using engineered designs. Ten discrete tests are proposed to address these and other concerns. These tests are divided into two groups: Seal component tests and performance confirmation tests. The seal component tests are thorough small-scale in situ tests, the intermediate-scale borehole seal tests, the fracture grouting tests, the surface backfill tests, and the grouted rock mass tests. The seal system tests are the seepage control tests, the backfill tests, the bulkhead test in the Calico Hills unit, the large-scale shaft seal and shaft fill tests, and the remote borehole sealing tests. The tests are proposed to be performed in six discrete areas, including welded and non-welded environments, primarily located outside the potential repository area. The final selection of sealing tests will depend on the nature of the geologic and hydrologic conditions encountered during the development of the Exploratory Studies Facility and detailed numerical analyses. Tests are likely to be performed both before and after License Application.

  18. HIV Testing and Antiretroviral Therapy Initiation at Birth: Views from ...

    African Journals Online (AJOL)

    HIV Testing and Antiretroviral Therapy Initiation at Birth: Views from a Primary Care Setting in Khayelitsha. A Nelson, J Maritz, J Giddy, L Frigati, H Rabie, G van Cutsem, T Mutseyekwa, N Jange, J Bernheimer, M Cotton, V Cox ...

  19. The Florida State Initial Teacher Certification Test: A Case Study.

    Science.gov (United States)

    Dorn, Charles M.

    1989-01-01

    Describes the development of the art certification examination which was designed for the Florida State Initial Teacher Certification Test. Discusses problems of subjectivity, content, and question format. Suggests criteria which can guide the development of viable college art education programs that can adequately prepare teachers in the areas of…

  20. Nearly Efficient Likelihood Ratio Tests for Seasonal Unit Roots

    DEFF Research Database (Denmark)

    Jansson, Michael; Nielsen, Morten Ørregaard

    In an important generalization of zero frequency autore- gressive unit root tests, Hylleberg, Engle, Granger, and Yoo (1990) developed regression-based tests for unit roots at the seasonal frequencies in quarterly time series. We develop likelihood ratio tests for seasonal unit roots and show...... that these tests are "nearly efficient" in the sense of Elliott, Rothenberg, and Stock (1996), i.e. that their local asymptotic power functions are indistinguishable from the Gaussian power envelope. Currently available nearly efficient testing procedures for seasonal unit roots are regression-based and require...... the choice of a GLS detrending parameter, which our likelihood ratio tests do not....

  1. Effect of different photo-initiators and light curing units on degree of conversion of composites.

    Science.gov (United States)

    Brandt, William Cunha; Schneider, Luis Felipe Jochims; Frollini, Elisabete; Correr-Sobrinho, Lourenço; Sinhoreti, Mário Alexandre Coelho

    2010-01-01

    The aim of this study was to evaluate: (i) the absorption of photo-initiators and emission spectra of light curing units (LCUs); and (ii) the degree of conversion (DC) of experimental composites formulated with different photo-initiators when activated by different LCUs. Blends of BisGMA, UDMA, BisEMA and TEGDMA with camphorquinone (CQ) and/ or 1-phenyl-1,2-propanedione (PPD) were prepared. Dimethylaminoethyl methacrylate (DMAEMA) was used as co-initiator. Each mixture was loaded with 65 wt% of silanated filler particles. One quartz-tungsten-halogen - QTH (XL 2500, 3M/ESPE) and two lightemitting diode (LED) LCUs (UltraBlue IS, DMC and UltraLume LED 5, Ultradent) were used for activation procedures. Irradiance (mW/cm²) was calculated by the ratio of the output power by the area of the tip, and spectral distribution with a spectrometer (USB 2000). The absorption curve of each photo-initiator was determined using a spectrophotometer (Varian Cary 5G). DC was assessed by Fourier transformed infrared spectroscopy. Data were submitted to two-way ANOVA and Tukey's test (5%). No significant difference was found for DC values when using LED LCUs regardless of the photo-initiator type. However, PPD showed significantly lower DC values than composites with CQ when irradiated with QTH. PPD produced DC values similar to those of CQ, but it was dependent on the LCU type.

  2. Initial acceptance test experience with FFTF plant equipment

    International Nuclear Information System (INIS)

    Brown, R.K.; Coleman, K.A.; Mahaffey, M.K.; McCargar, C.G.; Young, M.W.

    1978-09-01

    The purpose of this paper is to examine the initial acceptance test experience of certain pieces of auxiliary equipment of the Fast Flux Test Facility (FFTF). The scope focuses on the DHX blowers and drive train, inert gas blowers, H and V containment isolation valves, and the Surveillance and In-service Inspection (SISI) transporter and trolley. For each type of equipment, the discussion includes a summary of the design and system function, installation history, preoperational acceptance testing procedures and results, and unusual events and resolutions

  3. HIV Testing in the United States

    Science.gov (United States)

    ... testing is offered at CDC-funded testing sites (accounting for more than 3 million tests) and in ... text Each state Medicaid program determines its own definition of medical necessity, although it generally refers to ...

  4. Drop performance test and evaluation for HANARO shutoff units

    International Nuclear Information System (INIS)

    Jung, Y. H.; Cho, Y. K.; Lee, J. H.; Choi, Y. S.; Woo, J. S.

    2004-01-01

    The function of the shutoff units of the HANARO is to rapidly insert the shutoff rod into the reactor core for safe shutdown of reactor. This paper describes drop performance test and evaluation for a shutoff unit for the technical verification of lifetime extension and localization of the HANARO shutoff units. We have performed preliminary drop performance tests for a shutoff unit at 1/2-core test loop and analyzed through the comparison with the test results performed during design verification test and the results of the periodic performance test in HANARO. It shows that the results of the local fabrication, installation and alignment for the shutoff unit meet the basic performance requirements, Furthermore, the performance evaluation method of the periodic drop test of the HANARO shutoff units is a conservative method comparing with the real drop time

  5. Testing the initial-final mass relationship of white dwarfs

    International Nuclear Information System (INIS)

    Catalan, S; Isern, J; Garcia-Berro, E; Ribas, I

    2009-01-01

    In this contribution we revisit the initial-final mass relationship of white dwarfs, which links the mass of a white dwarf with that of its progenitor in the main-sequence. Although this function is of paramount importance to several fields in modern astrophysics, it is still not well constrained either from the theoretical or the observational points of view. We present here a revision of the present semi-empirical initial-final mass relationship using all the available data and including our recent results obtained from studying white dwarfs in common proper motion pairs. We have also analyzed the results obtained so far to provide some clues on the dependence of this relationship on metallicity. Finally, we have also performed an indirect test of the initial-final mass relationship by studying its effect on the luminosity function and on the mass distribution of white dwarfs.

  6. Initial testing of a variable-stroke Stirling engine

    Science.gov (United States)

    Thieme, L. G.

    1985-01-01

    In support of the U.S. Department of Energy's Stirling Engine Highway Vehicle Systems Program, NASA Lewis Research Center is evaluating variable-stroke control for Stirling engines. The engine being tested is the Advenco Stirling engine; this engine was manufactured by Philips Research Laboratories of the Netherlands and uses a variable-angle swash-plate drive to achieve variable stroke operation. The engine is described, initial steady-state test data taken at Lewis are presented, a major drive system failure and subsequent modifications are described. Computer simulation results are presented to show potential part-load efficiency gains with variable-stroke control.

  7. Construction, testing, and initial operation of Fort St. Vrain PCRV

    International Nuclear Information System (INIS)

    Ople, F.S. Jr.; Neylan, A.J.

    1975-01-01

    The Fort St. Vrain (FSV) Nuclear Generating Station is the first station in the USA to use a prestressed concrete reactor vessel (PCRV). The PCRV was designed and constructed by General Atomic. Construction of the PCRV was completed in 1970; the pressure and leak tests were completed in 1971. The structural behavior of the PCRV has been monitored by installed instrumentation since start of construction. The highlights of the actual construction, testing, and initial operation of the PCRV, including a comparison of structural behavior, where possible, between observed data and analytical predictions. (U.S.)

  8. LWR aerosol containment experiments (LACE) program and initial test results

    International Nuclear Information System (INIS)

    Muhlestein, L.D.; Hilliard, R.K.; Bloom, G.R.; McCormack, J.D.; Rahn, F.J.

    1985-01-01

    The LWR aerosol containment experiments (LACE) program is described. The LACE program is being performed at the Hanford Engineer Development Laboratory (operated by Westinghouse Hanford Company) and the initial tests are sponsored by EPRI. The objectives of the LACE program are: to demonstrate, at large-scale, inherent radioactive aerosol retention behavior for postulated high consequence LWR accident situations; and to provide a data base to be used for aerosol behavior . Test results from the first phase of the LACE program are presented and discussed. Three large-scale scoping tests, simulating a containment bypass accident sequence, demonstrated the extent of agglomeration and deposition of aerosols occurring in the pipe pathway and vented auxiliary building under realistic accident conditions. Parameters varied during the scoping tests were aerosol type and steam condensation

  9. Unit testing of AngularJS : A look into writing tests for web application

    OpenAIRE

    Karttunen, Joel

    2016-01-01

    This task was assigned by Protacon Solutions Oy with the objective set to study and implement unit testing in AngularJS JavaScript framework as part of the development process of the customer’s application. The thesis focuses on studying the AngularJS framework and if and how its design philosophy complements the unit testing principles. The focus was on studying unit testing via developing unit tests iteratively onto the application created beforehand. The tests were created with Jas...

  10. A New Nonlinear Unit Root Test with Fourier Function

    OpenAIRE

    Güriş, Burak

    2017-01-01

    Traditional unit root tests display a tendency to be nonstationary in the case of structural breaks and nonlinearity. To eliminate this problem this paper proposes a new flexible Fourier form nonlinear unit root test. This test eliminates this problem to add structural breaks and nonlinearity together to the test procedure. In this test procedure, structural breaks are modeled by means of a Fourier function and nonlinear adjustment is modeled by means of an Exponential Smooth Threshold Autore...

  11. The United Nations development programme initiative for sustainable energy

    Energy Technology Data Exchange (ETDEWEB)

    Hurry, S.

    1997-12-01

    Energy is central to current concerns about sustainable human development, affecting economic and social development; economic growth, the local, national, regional, and global environment; the global climate; a host of social concerns, including poverty, population, and health, the balance of payments, and the prospects for peace. Energy is not an end in itself, but rather the means to achieve the goals of sustainable human development. The energy systems of most developing countries are in serious crisis involving insufficient levels of energy services, environmental degradation, inequity, poor technical and financial performance, and capital scarcity. Approximately 2.5 billion people in the developing countries have little access to commercial energy supplies. Yet the global demand for energy continues to grow: total primary energy is projected to grow from 378 exajoules (EJ) per year in 1990 to 571 EJ in 2020, and 832 EJ in 2050. If this increase occurs using conventional approaches and energy sources, already serious local (e.g., indoor and urban air pollution), regional (eg., acidification and land degradation), and global (e.g., climate change) environmental problems will be critically aggravated. There is likely to be inadequate capital available for the needed investments in conventional energy sources. Current approaches to energy are thus not sustainable and will, in fact, make energy a barrier to socio-economic development. What is needed now is a new approach in which energy becomes an instrument for sustainable development. The two major components of a sustainable energy strategy are (1) more efficient energy use, especially at the point of end-use, and (2) increased use of renewable sources of energy. The UNDP Initiative for Sustainable Energy (UNISE) is designed to harness opportunities in these areas to build upon UNDP`s existing energy activities to help move the world toward a more sustainable energy strategy by helping program countries.

  12. AGM-69A Joint Test Unit

    Science.gov (United States)

    1975-11-15

    that the JTU payload will reliably and effectively meet SAC test requirements. However, the inherent absence of a flight termination (command destruct...ubsequent post fuzing anomalies were observed at the Air Force Eastern Test Range ( AFETR ) on five of the six BULLET .BLITZ II missions. The severity of these...some effect on mission planning and trajectory positioning on the test range. With a severe tumble after fuzing, it is possible that the missile will

  13. Applicability of modified burst test data to reactivity initiated accident

    Energy Technology Data Exchange (ETDEWEB)

    Yueh, K., E-mail: yuehky@hotmail.com

    2017-05-15

    A comprehensive irradiated cladding mechanical property dataset was generated by a recently developed modified burst test (MBT) under reactivity initiated accident (RIA) loading conditions [1,2]. The test data contains a wide range of test conditions that could bridge the gap between fast transient test reactor data (short pulse and/or low temperature) and prototypical commercial reactor conditions. This paper documents an evaluation performed to demonstrate the applicability of the MBT data to fuel cladding performance under RIA conditions. The current effort includes a comparison of calculated fuel cladding failure/burst strain for tests conducted at the Japan Atomic Energy Agency's (JAEA) Nuclear Safety Research Reactor (NSRR) to the MBT dataset, and an evaluation of potential mechanisms on how some NSRR tests survived beyond the cladding loading capacity. A simple shell model, coupled with temperature output from the Falcon fuel performance code, was used to calculate the fuel pellet thermal expansion of NSRR tests at the point of failure. The calculated fuel pellet thermal expansion correlates well directly with the MBT data at similar loading conditions. A 3-dimensional (3D) finite element analysis (FEA) model was used to evaluate fuel movement potential during a RIA. The evaluation indicates fuel relocation into the pellet chamfer and later into the dish is possible once a temperature threshold is reached before cladding failure and thus could significantly increase the fuel rod energy absorption capacity in a RIA event.

  14. Temelin 1000 MW Units active testing stage - commissioning experience

    International Nuclear Information System (INIS)

    Ubra, O.; Riha, V.

    2003-01-01

    There were three basic stages of the NPP Temelin Units active testing stage- The zero and low power testing, The power ascension testing and Plant Performance Test. The main objective of the start- up process stages and the testing procedures including some operational experience are described in the paper. (author)

  15. A Unit-Test Framework for Database Applications

    DEFF Research Database (Denmark)

    Christensen, Claus Abildgaard; Gundersborg, Steen; de Linde, Kristian

    The outcome of a test of an application that stores data in a database naturally depends on the state of the database. It is therefore important that test developers are able to set up and tear down database states in a simple and efficient manner. In existing unit-test frameworks, setting up...... test can be minimized. In addition, the reuse between unit tests can speed up the execution of test suites. A performance test on a medium-size project shows a 40% speed up and an estimated 25% reduction in the number of lines of test code....

  16. Initial CGE Model Results Summary Exogenous and Endogenous Variables Tests

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, Brian Keith [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Boero, Riccardo [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rivera, Michael Kelly [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-07

    The following discussion presents initial results of tests of the most recent version of the National Infrastructure Simulation and Analysis Center Dynamic Computable General Equilibrium (CGE) model developed by Los Alamos National Laboratory (LANL). The intent of this is to test and assess the model’s behavioral properties. The test evaluated whether the predicted impacts are reasonable from a qualitative perspective. This issue is whether the predicted change, be it an increase or decrease in other model variables, is consistent with prior economic intuition and expectations about the predicted change. One of the purposes of this effort is to determine whether model changes are needed in order to improve its behavior qualitatively and quantitatively.

  17. SmartUnit: Empirical Evaluations for Automated Unit Testing of Embedded Software in Industry

    OpenAIRE

    Zhang, Chengyu; Yan, Yichen; Zhou, Hanru; Yao, Yinbo; Wu, Ke; Su, Ting; Miao, Weikai; Pu, Geguang

    2018-01-01

    In this paper, we aim at the automated unit coverage-based testing for embedded software. To achieve the goal, by analyzing the industrial requirements and our previous work on automated unit testing tool CAUT, we rebuild a new tool, SmartUnit, to solve the engineering requirements that take place in our partner companies. SmartUnit is a dynamic symbolic execution implementation, which supports statement, branch, boundary value and MC/DC coverage. SmartUnit has been used to test more than one...

  18. Mastering Unit testing using Mockito and JUnit

    CERN Document Server

    Acharya, Sujoy

    2014-01-01

    A practical and easy-to-follow, yet comprehensive, guide to learning advanced JUnit testing. Each topic is explained and placed in context, and for the more inquisitive, there are more details of the concepts used. This book is for you if you are a developer with some experience in Java application development as well as a basic knowledge of JUnit testing. But for those whose skill set is void of any prior experience with JUnit testing, the book also covers basic fundamentals to get you acquainted with the concepts before putting them into practise.

  19. Experimental data report for Test TS-2 reactivity initiated accident test in NSRR with pre-irradiated BWR fuel rod

    International Nuclear Information System (INIS)

    Nakamura, Takehiko; Yoshinaga, Makio; Sobajima, Makoto; Fujishiro, Toshio; Kobayashi, Shinsho; Yamahara, Takeshi; Sukegawa, Tomohide; Kikuchi, Teruo

    1993-02-01

    This report presents experimental data for Test TS-2 which was the second test in a series of Reactivity Initiated Accident (RIA) condition test using pre-irradiated BWR fuel rods, performed at the Nuclear Safety Research Reactor (NSRR) in February, 1990. Test fuel rod used in the Test TS-2 was a short sized BWR (7x7) type rod which was fabricated from a commercial rod irradiated at Tsuruga Unit 1 power reactor. The fuel had an initial enrichment of 2.79% and a burnup of 21.3Gwd/tU (bundle average). A pulse irradiation of the test fuel rod was performed under a cooling condition of stagnant water at atmospheric pressure and at ambient temperature which simulated a BWR's cold start-up RIA event. The energy deposition of the fuel rod in this test was evaluated to be 72±5cal/g·fuel (66±5cal/g·fuel in peak fuel enthalpy) and no fuel failure was observed. Descriptions on test conditions, test procedures, transient behavior of the test rod during the pulse irradiation, and, results of pre and post pulse irradiation examinations are described in this report. (author)

  20. Proton Testing of Advanced Stellar Compass Digital Processing Unit

    DEFF Research Database (Denmark)

    Thuesen, Gøsta; Denver, Troelz; Jørgensen, Finn E

    1999-01-01

    The Advanced Stellar Compass Digital Processing Unit was radiation tested with 300 MeV protons at Proton Irradiation Facility (PIF), Paul Scherrer Institute, Switzerland.......The Advanced Stellar Compass Digital Processing Unit was radiation tested with 300 MeV protons at Proton Irradiation Facility (PIF), Paul Scherrer Institute, Switzerland....

  1. Apollo telescope mount thermal systems unit thermal vacuum test

    Science.gov (United States)

    Trucks, H. F.; Hueter, U.; Wise, J. H.; Bachtel, F. D.

    1971-01-01

    The Apollo Telescope Mount's thermal systems unit was utilized to conduct a full-scale thermal vacuum test to verify the thermal design and the analytical techniques used to develop the thermal mathematical models. Thermal vacuum test philosophy, test objectives configuration, test monitoring, environment simulation, vehicle test performance, and data correlation are discussed. Emphasis is placed on planning and execution of the thermal vacuum test with particular attention on problems encountered in conducting a test of this maguitude.

  2. Genital Herpes - Initial Visits to Physicians' Offices, United States, 1966-2012

    Science.gov (United States)

    ... Archive Data & Statistics Sexually Transmitted Diseases Figure 48. Genital Herpes — Initial Visits to Physicians’ Offices, United States, 1966 – ... Statistics page . NOTE : The relative standard errors for genital herpes estimates of more than 100,000 range from ...

  3. Initial testing of the tritium systems at the Tokamak Fusion Test Reactor

    International Nuclear Information System (INIS)

    Anderson, J.L.; Sissingh, R.A.P.; Gentile, C.A.; Rossmassler, R.L.; Walters, R.T.; Voorhees, D.R.

    1993-01-01

    The Tokamak Fusion Test Reactor (TFTR) at Princeton will start its D-T experiments in late 1993, introducing and operating the tokamak with tritium in order to begin the study of burning plasma physics in D-T. Trace tritium injection experiments, using small amounts of tritium will begin in the fall of 1993. In preparation for these experiments, a series of tests with low concentrations of tritium inn deuterium have been performed as an initial qualification of the tritium systems. These tests began in April 1993. This paper describes the initial testing of the equipment in the TFTR tritium facility

  4. Initial Mechanical Testing of Superalloy Lattice Block Structures Conducted

    Science.gov (United States)

    Krause, David L.; Whittenberger, J. Daniel

    2002-01-01

    , which were not considered in the simplified computer models. The fatigue testing proved the value of redundancies since specimen strength was maintained even after the fracture of one or two ligaments. This ongoing test program is planned to continue through high-temperature testing. Also scheduled for testing are IN 718 lattice block panels with integral face sheets, as well as specimens cast from a higher temperature alloy. The initial testing suggests the value of this technology for large panels under low and moderate pressure loadings and for high-risk, damage-tolerant structures. Potential aeropropulsion uses for lattice blocks include turbine-engine actuated panels, exhaust nozzle flaps, and side panel structures.

  5. Technique for unit testing of safety software verification and validation

    International Nuclear Information System (INIS)

    Li Duo; Zhang Liangju; Feng Junting

    2008-01-01

    The key issue arising from digitalization of the reactor protection system for nuclear power plant is how to carry out verification and validation (V and V), to demonstrate and confirm the software that performs reactor safety functions is safe and reliable. One of the most important processes for software V and V is unit testing, which verifies and validates the software coding based on concept design for consistency, correctness and completeness during software development. The paper shows a preliminary study on the technique for unit testing of safety software V and V, focusing on such aspects as how to confirm test completeness, how to establish test platform, how to develop test cases and how to carry out unit testing. The technique discussed here was successfully used in the work of unit testing on safety software of a digital reactor protection system. (authors)

  6. Unit testing as a teaching tool in higher education

    Directory of Open Access Journals (Sweden)

    Peláez Canek

    2016-01-01

    Full Text Available Unit testing in the programming world has had a profound impact in the way modern complex systems are developed. Many Open Source and Free Software projects encourage (and in some cases, mandate the use of unit tests for new code submissions, and many software companies around the world have incorporated unit testing as part of their standard developing practices. And although not all software engineers use them, very few (if at all object their use. However, there is almost no research available pertaining the use of unit tests as a teaching tool in introductory programming courses. I have been teaching introductory programming courses in the Computer Sciences program at the Sciences Faculty in the National Autonomous University of Mexico for almost ten years, and since 2013 I have been using unit testing as a teaching tool in those courses. The intent of this paper is to discuss the results of this experience.

  7. Acute-Onset Panhypopituitarism Nearly Missed by Initial Cosyntropin Testing.

    Science.gov (United States)

    Blum, Claudine A; Schneeberger, Daniel; Lang, Matthias; Rakic, Janko; Michot, Marc Philippe; Müller, Beat

    2017-01-01

    Diagnosis of adrenal crisis and panhypopituitarism in patients with septic shock is difficult but crucial for outcome. A 66-year-old woman with metastasized breast cancer presented to the ED with respiratory insufficiency and septic shock after a 2-day history of the flu. After transfer to the ICU, corticosteroids were started in addition to antibiotics, as the patient was vasopressor-nonresponsive. Diabetes insipidus was diagnosed due to polyuria and treated with 4 mg desmopressin. Thereafter, norepinephrine could be tapered rapidly. On day 2, basal cortisol was 136 nmol/L with an increase to 579 nmol/L in low-dose cosyntropin testing. Polyuria had not developed again. Therefore, corticosteroids were stopped. On day 3, the patient developed again nausea, vomiting, and polyuria. Adrenal crisis and diabetes insipidus were postulated. Corticosteroids and desmopressin were restarted. Further testing confirmed panhypopituitarism. MRI showed a new sellar metastasis. After 2 weeks, stimulated cortisol in cosyntropin testing reached only 219 nmol/l, confirming adrenal insufficiency. The time course showed that the adrenal glands took 2 weeks to atrophy after loss of pituitary ACTH secretion. Therefore, a misleading result of the cosyntropin test in the initial phase with low basal cortisol and allegedly normal response to exogenous ACTH may be seen. Cosyntropin testing in the critically ill should be interpreted with caution and in the corresponding clinical setting.

  8. Scientific investigation plan for initial engineered barrier system field tests

    International Nuclear Information System (INIS)

    Wunan Lin.

    1993-02-01

    The purpose of this Scientific Investigation Plan (SIP) is to describe tests known as Initial Engineered Barrier System Field Tests (IEBSFT) and identified by Work Breakdown Structure as WBS 1.2.2.2.4. The IEBSFT are precursors to the Engineered Barrier System Field Test (EBSFT), WBS 1.2.2.2.4, to be conducted in the Exploratory Study Facility (ESF) at Yucca Mountain. The EBSFT and IEBSFT are designed to provide information on the interaction between waste packages (simulated by heated containers) and the surrounding rock mass, its vadose water, and infiltrated water. Heater assemblies will be installed in drifts or boreholes openings and heated to measure moisture movement during heat-up and subsequent cool-down of the rock mass. In some of the tests, infiltration of water into the heated rock mass will be studied. Throughout the heating and cooling cycle, instruments installed in the rock will monitor such parameters as temperature, moisture content, concentration of some chemical species, and stress and strain. Rock permeability measurements, rock and fluid (water and gas) sampling, and fracture pattern measurements will also be made before and after the test

  9. Acute-Onset Panhypopituitarism Nearly Missed by Initial Cosyntropin Testing

    Directory of Open Access Journals (Sweden)

    Claudine A. Blum

    2017-01-01

    Full Text Available Introduction. Diagnosis of adrenal crisis and panhypopituitarism in patients with septic shock is difficult but crucial for outcome. Case. A 66-year-old woman with metastasized breast cancer presented to the ED with respiratory insufficiency and septic shock after a 2-day history of the flu. After transfer to the ICU, corticosteroids were started in addition to antibiotics, as the patient was vasopressor-nonresponsive. Diabetes insipidus was diagnosed due to polyuria and treated with 4 mg desmopressin. Thereafter, norepinephrine could be tapered rapidly. On day 2, basal cortisol was 136 nmol/L with an increase to 579 nmol/L in low-dose cosyntropin testing. Polyuria had not developed again. Therefore, corticosteroids were stopped. On day 3, the patient developed again nausea, vomiting, and polyuria. Adrenal crisis and diabetes insipidus were postulated. Corticosteroids and desmopressin were restarted. Further testing confirmed panhypopituitarism. MRI showed a new sellar metastasis. After 2 weeks, stimulated cortisol in cosyntropin testing reached only 219 nmol/l, confirming adrenal insufficiency. Discussion. The time course showed that the adrenal glands took 2 weeks to atrophy after loss of pituitary ACTH secretion. Therefore, a misleading result of the cosyntropin test in the initial phase with low basal cortisol and allegedly normal response to exogenous ACTH may be seen. Cosyntropin testing in the critically ill should be interpreted with caution and in the corresponding clinical setting.

  10. Initial clinical test of a breast-PET scanner

    International Nuclear Information System (INIS)

    Raylman, Raymond R.; Koren, Courtney; Schreiman, Judith S.; Majewski, Stan; Marano, Gary D.; Abraham, Jame; Kurian, Sobha; Hazard, Hannah; Filburn, Shannon

    2011-01-01

    The goal of this initial clinical study was to test a new positron emission/tomography imager and biopsy system (PEM/PET) in a small group of selected subjects to assess its clinical imaging capabilities. Specifically, the main task of this study is to determine whether the new system can successfully be used to produce images of known breast cancer and compare them to those acquired by standard techniques. The PEM/PET system consists of two pairs of rotating radiation detectors located beneath a patient table. The scanner has a spatial resolution of ∼2 mm in all three dimensions. The subjects consisted of five patients diagnosed with locally advanced breast cancer ranging in age from 40 to 55 years old scheduled for pre-treatment, conventional whole body PET imaging with F-18 Fluorodeoxyglucose (FDG). The primary lesions were at least 2 cm in diameter. The images from the PEM/PET system demonstrated that this system is capable of identifying some lesions not visible in standard mammograms. Furthermore, while the relatively large lesions imaged in this study where all visualised by a standard whole body PET/CT scanner, some of the morphology of the tumours (ductal infiltration, for example) was better defined with the PEM/PET system. Significantly, these images were obtained immediately following a standard whole body PET scan. The initial testing of the new PEM/PET system demonstrated that the new system is capable of producing good quality breast-PET images compared standard methods.

  11. Safeguards First Principles Initiative at the Nevada Test Site

    International Nuclear Information System (INIS)

    Johnson, Geneva

    2007-01-01

    The Material Control and Accountability (MC and A) program at the Nevada Test Site (NTS) was selected as a test bed for the Safeguards First Principles Initiative (SFPI). The implementation of the SFPI is evaluated using the system effectiveness model and the program is managed under an approved MC and A Plan. The effectiveness model consists of an evaluation of the critical elements necessary to detect, deter, and/or prevent the theft or diversion of Special Nuclear Material (SNM). The modeled results indicate that the MC and A program established under this variance is still effective, without creating unacceptable risk. Extensive performance testing is conducted through the duration of the pilot to ensure the protection system is effective and no material is at an unacceptable risk. The pilot was conducted from January 1, 2007, through May 30, 2007. This paper will discuss the following activities in association with SFPI: (1) Development of Timeline; (2) Crosswalk of DOE Order and SFPI; (3) Peer Review; (4) Deviation; (5) MC and A Plan and Procedure changes; (6) Changes implemented at NTS; (7) Training; and (8) Performance Test

  12. Automatic TV X-ray unit for testing aluminium castings

    International Nuclear Information System (INIS)

    Morgunov, V.I.; Firstov, V.G.; Kisin, V.I.; Savostenok, M.I.

    1989-01-01

    The automatic TV X-ray unit for testing of aluminum alloy castings in a flow is described. The unit includes RAP-150/300 X-ray apparatus and PI-60TK TV X-ray device. The biological protection chamber and the common control board are the main functional units. The tests of the unit have shown that as regards its characteristics it is not worse than its foreign-made analogues, for example, devices of the DP-35 and DP-38 type of the 'Seifert' company

  13. The comparison of the unit test tools JUnit and TestNG

    OpenAIRE

    Šarkanj, Aleš

    2011-01-01

    Testing holds an important role in developing software. It is a process ensuring software works as expected. An important part of testing is unit testing as the basic testing level. The purpose of this thesis is comparing JUnit and TestNG, two of the most popular unit testing tools in Java. In the first part we will present testing and its purpose within software development. We will also present the basic terminology and levels of testing. Further on the area of unit testing will be pr...

  14. Experimental data report for Test TS-1 Reactivity Initiated Accident Test in NSRR with pre-irradiated BWR fuel rod

    International Nuclear Information System (INIS)

    Nakamura, Takehiko; Yoshinaga, Makio; Sobajima, Makoto; Fujishiro, Toshio; Horiki, Ohichiro; Yamahara, Takeshi; Ichihashi, Yoshinori; Kikuchi, Teruo

    1992-01-01

    This report presents experimental data for Test TS-1 which was the first in a series of tests, simulating Reactivity Initiated Accident (RIA) conditions using pre-irradiated BWR fuel rods, performed in the Nuclear Safety Research Reactor (NSRR) in October, 1989. Test fuel rod used in the Test TS-1 was a short-sized BWR (7 x 7) type rod which was fabricated from a commercial rod provided from Tsuruga Unit 1 power reactor. The fuel had an initial enrichment of 2.79 % and burnup of 21.3 GWd/t (bundle average). Pulse irradiation was performed at a condition of stagnant water cooling, atmospheric pressure and ambient temperature using a newly developed double container-type capsule. Energy deposition of the rod in this test was evaluated to be about 61 cal/g·fuel (55 cal/g·fuel in peak fuel enthalpy) and no fuel failure was observed. Descriptions on test conditions, test procedures, fuel burnup measurements, transient behavior of the test rod during pulse irradiation and results of post pulse irradiation examinations are contained in this report. (author)

  15. ACO-Initialized Wavelet Neural Network for Vibration Fault Diagnosis of Hydroturbine Generating Unit

    OpenAIRE

    Xiao, Zhihuai; He, Xinying; Fu, Xiangqian; Malik, O. P.

    2015-01-01

    Considering the drawbacks of traditional wavelet neural network, such as low convergence speed and high sensitivity to initial parameters, an ant colony optimization- (ACO-) initialized wavelet neural network is proposed in this paper for vibration fault diagnosis of a hydroturbine generating unit. In this method, parameters of the wavelet neural network are initialized by the ACO algorithm, and then the wavelet neural network is trained by the gradient descent algorithm. Amplitudes of the fr...

  16. Quick setup of test unit for accelerator control system

    International Nuclear Information System (INIS)

    Fu, W.; D'Ottavio, T.; Gassner, D.; Nemesure, S.; Morris, J.

    2011-01-01

    Testing a single hardware unit of an accelerator control system often requires the setup of a program with graphical user interface. Developing a dedicated application for a specific hardware unit test could be time consuming and the application may become obsolete after the unit tests. This paper documents a methodology for quick design and setup of an interface focused on performing unit tests of accelerator equipment with minimum programming work. The method has three components. The first is a generic accelerator device object (ADO) manager which can be used to setup, store, and log testing controls parameters for any unit testing system. The second involves the design of a TAPE (Tool for Automated Procedure Execution) sequence file that specifies and implements all te testing and control logic. The sting third is the design of a PET (parameter editing tool) page that provides the unit tester with all the necessary control parameters required for testing. This approach has been used for testing the horizontal plane of the Stochastic Cooling Motion Control System at RHIC.

  17. Phased Startup Initiative Phases 3 and 4 Test Plan and Test Specification (OCRWM)

    International Nuclear Information System (INIS)

    PITNER, A.L.

    2000-01-01

    Construction for the Spent Nuclear Fuel (SNF) Project facilities is continuing per the Level III Baseline Schedule, and installation of the Fuel Retrieval System (FRS) and Integrated Water Treatment System (IWTS) in K West Basin is now complete. In order to accelerate the project, a phased start up strategy to initiate testing of the FRS and IWTS early in the overall project schedule was proposed (Williams 1999). Wilkinson (1999) expands the definition of the original proposal into four functional testing phases of the Phased Startup Initiative (PSI). Phases 1 and 2 are based on performing functional tests using dummy fuel. These tests are described in separate planning documents. This test plan provides overall guidance for Phase 3 and 4 tests, which are performed using actual irradiated N fuel assemblies. The overall objective of the Phase 3 and 4 testing is to verify how the FRS and IWTS respond while processing actual fuel. Conducting these tests early in the project schedule will allow identification and resolution of equipment and process problems before they become activities on the start-up critical path. The specific objectives of this test plan are to: (1) Define the test scope for the FRS and IWTS; (2) Provide detailed test requirements that can be used to write the specific test procedures; (3) Define data required and measurements to be taken. Where existing methods to obtain these do not exist, enough detail will be provided to define required additional equipment; and (4) Define specific test objectives and acceptance criteria

  18. ACO-Initialized Wavelet Neural Network for Vibration Fault Diagnosis of Hydroturbine Generating Unit

    Directory of Open Access Journals (Sweden)

    Zhihuai Xiao

    2015-01-01

    Full Text Available Considering the drawbacks of traditional wavelet neural network, such as low convergence speed and high sensitivity to initial parameters, an ant colony optimization- (ACO- initialized wavelet neural network is proposed in this paper for vibration fault diagnosis of a hydroturbine generating unit. In this method, parameters of the wavelet neural network are initialized by the ACO algorithm, and then the wavelet neural network is trained by the gradient descent algorithm. Amplitudes of the frequency components of the hydroturbine generating unit vibration signals are used as feature vectors for wavelet neural network training to realize mapping relationship from vibration features to fault types. A real vibration fault diagnosis case result of a hydroturbine generating unit shows that the proposed method has faster convergence speed and stronger generalization ability than the traditional wavelet neural network and ACO wavelet neural network. Thus it can provide an effective solution for online vibration fault diagnosis of a hydroturbine generating unit.

  19. Phased Startup Initiative Phase 3 and 4 Test Procedure (OCRWM)

    International Nuclear Information System (INIS)

    PAJUNEN, A.L.

    2000-01-01

    necessary. The fuel canisters to be processed shall be listed in the Fuel Campaign Letter and are identified in HNF-4898, ''Phased Startup Initiative Phases 3 and 4 Test Plan and Test Specifications (OCRWM)''

  20. Phase Startup Initiative Phases 3 and 4 Test Plan and Test Specification (OCRWM)

    International Nuclear Information System (INIS)

    PAJUNEN, A.L.; LANGEVIN, M.J.

    2000-01-01

    Construction for the Spent Nuclear Fuel (SNF) Project facilities is continuing per the Level III Baseline Schedule, and installation of the Fuel Retrieval System (FRS) and Integrated Water Treatment System (IWTS) in K West Basin is now complete. In order to accelerate the project, a phased start up strategy to initiate testing of the FRS and IWTS early in the overall project schedule was proposed (Williams 1999). Wilkinson (1999) expands the definition of the original proposal into four functional testing phases of the Phased Startup Initiative (PSI). Phases 1 and 2 are based on performing functional tests using dummy fuel. This test plan provides overall guidance for Phase 3 and 4 tests, which are performed using actual irradiated N fuel assemblies. The overall objective of the Phase 3 and 4 testing is to verify how the FRS and IWTS respond while processing actual fuel. Conducting these tests early in the project schedule will allow identification and resolution of equipment and process problems before they become activities on the start-up critical path. The specific objectives of this test plan are to: Define the Phase 3 and 4 test scope for the FRS and IWTS; Provide detailed test requirements that can be used to write the specific test procedures; Define data required and measurements to be taken. Where existing methods to obtain these do not exist, enough detail will be provided to define required additional equipment; and Define specific test objectives and acceptance criteria

  1. Phase Startup Initiative Phases 3 and 4 Test Plan and Test Specification ( OCRWM)

    Energy Technology Data Exchange (ETDEWEB)

    PAJUNEN, A.L.; LANGEVIN, M.J.

    2000-08-07

    Construction for the Spent Nuclear Fuel (SNF) Project facilities is continuing per the Level III Baseline Schedule, and installation of the Fuel Retrieval System (FRS) and Integrated Water Treatment System (IWTS) in K West Basin is now complete. In order to accelerate the project, a phased start up strategy to initiate testing of the FRS and IWTS early in the overall project schedule was proposed (Williams 1999). Wilkinson (1999) expands the definition of the original proposal into four functional testing phases of the Phased Startup Initiative (PSI). Phases 1 and 2 are based on performing functional tests using dummy fuel. This test plan provides overall guidance for Phase 3 and 4 tests, which are performed using actual irradiated N fuel assemblies. The overall objective of the Phase 3 and 4 testing is to verify how the FRS and IWTS respond while processing actual fuel. Conducting these tests early in the project schedule will allow identification and resolution of equipment and process problems before they become activities on the start-up critical path. The specific objectives of this test plan are to: Define the Phase 3 and 4 test scope for the FRS and IWTS; Provide detailed test requirements that can be used to write the specific test procedures; Define data required and measurements to be taken. Where existing methods to obtain these do not exist, enough detail will be provided to define required additional equipment; and Define specific test objectives and acceptance criteria.

  2. CERN's PS Booster LLRF renovation : plans and initial beam tests

    CERN Document Server

    Angoletta, ME; Butterworth, A; Findlay, A; Leinonen, PM; Molendijk, JC; Pedersen, F; Sanchez-Quesada, J; Schokker, M

    2010-01-01

    In 2008 a project was started to renovate the CERN's PS Booster (PSB) low-level RF (LLRF). Required LLRF capabilities include frequency program, beam phase, radial and synchronization loops. The new LLRF will control the signals feeding the three RF cavities present in each ring; it will also shape the beam in a dual harmonic mode, operate a bunch splitting and create a longitudinal blow-up. The main benefits of this new LLRF are its full remote and cycle-to-cycle controllability, built-in observation capability and flexibility. The overall aim is to improve the robustness, maintainability and reliability of the PSB operation and to make it compatible with the injection from the future Linac4. This paper outlines the main characteristics of the software and hardware building blocks. Initial beam test results and hints on the main milestones and future work are also given.

  3. Local government units initiatives on coastal resource management in adjacent municipalities in Camarines Sur, Philippines

    Science.gov (United States)

    Faustino, A. Z.; Madela, H. L.

    2018-03-01

    This research was conducted to determine the local government units (LGUs) initiatives on coastal resource management (CRM) in adjacent municipalities in Camarines Sur, Philippines. The respondents of this study are 100 fisherfolk leaders in the municipalities of Calabanga, Tinambac and Siruma. Descriptive, comparative and evaluative methods of research were employed and a survey questionnaire was used as the primary tool in data gathering. On the test of difference, the computed F-value of 12.038 and p-value of .001 revealed a very high difference in the implementation of CRM initiatives in the adjacent municipalities. The respondents in this study live below the poverty threshold. The intrusion of commercial fishers and the use of active fishing gears inside the 15-km municipal waters significantly affect the marine habitat while fishpond conversion kills the natural cycle in the mangrove forests. However, the FOs membership in the Municipal Fisheries and Aquatic Resources Management Council empower them to engage in governance which can be a venue for them to recommend policies related to CRM. As a result of this study, a CRM monitoring and evaluation model was crafted to guide the LGUs in the review, revision and crafting of CRM programs.

  4. Integrated infrastructure initiatives for material testing reactor innovations

    International Nuclear Information System (INIS)

    Dekeyser, Jean; Vermeeren, Ludo; Iracane, Daniel

    2011-01-01

    Highlights: → The EU FP7 MTR+I3 project has initiated a durable cooperation between MTR operators. → Improvements in irradiation test device technology and instrumentation were achieved. → Professional training efforts were streamlined and best practices were exchanged. → A framework has been set up to coordinate and optimize the use of MTRs in the EU. - Abstract: The key goal of the European FP6 project MTR+I3 was to build a durable cooperation between Material Testing Reactor (MTR) operators and relevant laboratories that can maintain European leadership with updated capabilities and competences regarding reactor performances and irradiation technology. The MTR+I3 consortium was composed of 18 partners with a high level of expertise in irradiation-related services for all types of nuclear plants. This project covered activities that foster integration of the MTR community involved in designing, fabricating and operating irradiation devices through information exchange, know-how cross-fertilization, exchanges of interdisciplinary personnel, structuring of key-technology suppliers and professional training. The network produced best practice guidelines for selected irradiation activities. This project allowed to launch or to improve technical studies in various domains dealing with irradiation test device technology, experimental loop designs and instrumentation. Major results are illustrated in this paper. These concern in particular: on-line fuel power determination, neutron screen optimization, simulation of transmutation process, power transient systems, water chemistry and stress corrosion cracking, fission gas measurement, irradiation behaviour of electronic modules, mechanical loading under irradiation, high temperature gas loop technology, heavy liquid metal loop development and safety test instrumentation. One of the major benefits of this project is that, starting from a situation of fragmented resources in a strongly competitive sector, it has

  5. A simple nonstationary-volatility robust panel unit root test

    NARCIS (Netherlands)

    Demetrescu, Matei; Hanck, Christoph

    2012-01-01

    We propose an IV panel unit root test robust to nonstationary error volatility. Its finite-sample performance is convincing even for many units and strong cross-correlation. An application to GDP prices illustrates the inferential impact of nonstationary volatility. (C) 2012 Elsevier B.V. All rights

  6. A New Symmetrical Unit for Breakwater Armour : First Tests

    NARCIS (Netherlands)

    Salauddin, M.; Broere, A.; Van der Meer, J.W.; Verhagen, H.J.; Bijl, E.

    2015-01-01

    A new and symmetrical single layer armour unit, the crablock, has been designed in the UAE. One breakwater was reconstructed with crablock, but very limited testing had been performed. Just to become more acquainted with this new unit, pre-competitive research at a university has been performed,

  7. Integration testing through reusing representative unit test cases for high-confidence medical software.

    Science.gov (United States)

    Shin, Youngsul; Choi, Yunja; Lee, Woo Jin

    2013-06-01

    As medical software is getting larger-sized, complex, and connected with other devices, finding faults in integrated software modules gets more difficult and time consuming. Existing integration testing typically takes a black-box approach, which treats the target software as a black box and selects test cases without considering internal behavior of each software module. Though it could be cost-effective, this black-box approach cannot thoroughly test interaction behavior among integrated modules and might leave critical faults undetected, which should not happen in safety-critical systems such as medical software. This work anticipates that information on internal behavior is necessary even for integration testing to define thorough test cases for critical software and proposes a new integration testing method by reusing test cases used for unit testing. The goal is to provide a cost-effective method to detect subtle interaction faults at the integration testing phase by reusing the knowledge obtained from unit testing phase. The suggested approach notes that the test cases for the unit testing include knowledge on internal behavior of each unit and extracts test cases for the integration testing from the test cases for the unit testing for a given test criteria. The extracted representative test cases are connected with functions under test using the state domain and a single test sequence to cover the test cases is produced. By means of reusing unit test cases, the tester has effective test cases to examine diverse execution paths and find interaction faults without analyzing complex modules. The produced test sequence can have test coverage as high as the unit testing coverage and its length is close to the length of optimal test sequences. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Initial ACTR retrieval technology evaluation test material recommendations

    International Nuclear Information System (INIS)

    Powell, M.R.

    1996-04-01

    Millions of gallons of radiaoctive waste are contained in underground storage tanks at Hanford (SE Washington). Techniques for retrieving much of this waste from the storage tanks have been developed. Current baseline approach is to use sluice jets for single-shell tanks and mixer pumps for double-shell tanks. The Acquire Commercial Technology for Retrieval (ACTR) effort was initiated to identify potential improvements in or alternatives to the baseline waste retrieval methods. Communications with a variety of vendors are underway to identify improved methods that can be implemented at Hanford with little or no additional development. Commercially available retrieval methods will be evaluated by a combination of testing and system-level cost estimation. Current progress toward developing waste simulants for testing ACTR candidate methods is reported; the simulants are designed to model 4 different types of tank waste. Simulant recipes are given for wet sludge, hardpan/dried sludge,hard saltcake, and soft saltcake. Comparisons of the waste and simulant properties are documented in this report

  9. Nearly Efficient Likelihood Ratio Tests of the Unit Root Hypothesis

    DEFF Research Database (Denmark)

    Jansson, Michael; Nielsen, Morten Ørregaard

    Seemingly absent from the arsenal of currently available "nearly efficient" testing procedures for the unit root hypothesis, i.e. tests whose local asymptotic power functions are indistinguishable from the Gaussian power envelope, is a test admitting a (quasi-)likelihood ratio interpretation. We...... show that the likelihood ratio unit root test derived in a Gaussian AR(1) model with standard normal innovations is nearly efficient in that model. Moreover, these desirable properties carry over to more complicated models allowing for serially correlated and/or non-Gaussian innovations....

  10. Commercial landscape of noninvasive prenatal testing in the United States.

    Science.gov (United States)

    Agarwal, Ashwin; Sayres, Lauren C; Cho, Mildred K; Cook-Deegan, Robert; Chandrasekharan, Subhashini

    2013-06-01

    Cell-free fetal DNA-based noninvasive prenatal testing (NIPT) could significantly change the paradigm of prenatal testing and screening. Intellectual property (IP) and commercialization promise to be important components of the emerging debate about clinical implementation of these technologies. We have assembled information about types of testing, prices, turnaround times, and reimbursement of recently launched commercial tests in the United States from the trade press, news articles, and scientific, legal, and business publications. We also describe the patenting and licensing landscape of technologies underlying these tests and ongoing patent litigation in the United States. Finally, we discuss how IP issues may affect clinical translation of NIPT and their potential implications for stakeholders. Fetal medicine professionals (clinicians and researchers), genetic counselors, insurers, regulators, test developers, and patients may be able to use this information to make informed decisions about clinical implementation of current and emerging noninvasive prenatal tests. © 2013 John Wiley & Sons, Ltd.

  11. DART Core/Combustor-Noise Initial Test Results

    Science.gov (United States)

    Boyle, Devin K.; Henderson, Brenda S.; Hultgren, Lennart S.

    2017-01-01

    Contributions from the combustor to the overall propulsion noise of civilian transport aircraft are starting to become important due to turbofan design trends and advances in mitigation of other noise sources. Future propulsion systems for ultra-efficient commercial air vehicles are projected to be of increasingly higher bypass ratio from larger fans combined with much smaller cores, with ultra-clean burning fuel-flexible combustors. Unless effective noise-reduction strategies are developed, combustor noise is likely to become a prominent contributor to overall airport community noise in the future. The new NASA DGEN Aero0propulsion Research Turbofan (DART) is a cost-efficient testbed for the study of core-noise physics and mitigation. This presentation gives a brief description of the recently completed DART core combustor-noise baseline test in the NASA GRC Aero-Acoustic Propulsion Laboratory (AAPL). Acoustic data was simultaneously acquired using the AAPL overhead microphone array in the engine aft quadrant far field, a single midfield microphone, and two semi-infinite-tube unsteady pressure sensors at the core-nozzle exit. An initial assessment shows that the data is of high quality and compares well with results from a quick 2014 feasibility test. Combustor noise components of measured total-noise signatures were educed using a two-signal source-separation method an dare found to occur in the expected frequency range. The research described herein is aligned with the NASA Ultra-Efficient Commercial Transport strategic thrust and is supported by the NASA Advanced Air Vehicle Program, Advanced Air Transport Technology Project, under the Aircraft Noise Reduction Subproject.

  12. Charge-Control Unit for Testing Lithium-Ion Cells

    Science.gov (United States)

    Reid, Concha M.; Mazo, Michelle A.; Button, Robert M.

    2008-01-01

    A charge-control unit was developed as part of a program to validate Li-ion cells packaged together in batteries for aerospace use. The lithium-ion cell charge-control unit will be useful to anyone who performs testing of battery cells for aerospace and non-aerospace uses and to anyone who manufacturers battery test equipment. This technology reduces the quantity of costly power supplies and independent channels that are needed for test programs in which multiple cells are tested. Battery test equipment manufacturers can integrate the technology into their battery test equipment as a method to manage charging of multiple cells in series. The unit manages a complex scheme that is required for charging Li-ion cells electrically connected in series. The unit makes it possible to evaluate cells together as a pack using a single primary test channel, while also making it possible to charge each cell individually. Hence, inherent cell-to-cell variations in a series string of cells can be addressed, and yet the cost of testing is reduced substantially below the cost of testing each cell as a separate entity. The unit consists of electronic circuits and thermal-management devices housed in a common package. It also includes isolated annunciators to signal when the cells are being actively bypassed. These annunciators can be used by external charge managers or can be connected in series to signal that all cells have reached maximum charge. The charge-control circuitry for each cell amounts to regulator circuitry and is powered by that cell, eliminating the need for an external power source or controller. A 110-VAC source of electricity is required to power the thermal-management portion of the unit. A small direct-current source can be used to supply power for an annunciator signal, if desired.

  13. Initial tests of an 11.4 GHz magnicon amplifier

    International Nuclear Information System (INIS)

    Gold, S.H.; Sullivan, C.A.; Manheimer, W.M.; Hafizi, B.

    1994-01-01

    The magnicon, a scanning beam microwave amplifier related to the gyrocon, is a possible replacement for klystron amplifiers in future high-gradient linear accelerators. The magnicon circuit consists of a multicavity deflection system followed by an output cavity. The purpose of the deflection system is to spin up the electron beam phase-coherently to high transverse momentum. In order to do this, the deflection cavities employ rotating TM 11 modes, producing a gyrating electron beam whose centroid rotates about the cavity axis in synchronism with the advance in phase of the rf modes. The output cavity employs a cyclotron resonant mechanism to extract principally the transverse beam momentum. It employs an rf mode that rotates synchronously with the deflection cavity modes, and with the entry point of the electron beam into the output cavity, making possible a highly efficient interaction. The NRL magnicon uses a 100--200 A, 500 keV beam produced by a cold-cathode diode on the NRL Long-Pulse Accelerator Facility. The first cavity is externally driven at 5.7 GHz, while the output cavity is designed to produce megawatts of power at 11.4 GHz in the TM 210 mode. In this paper, the authors present a progress report on the NRL magnicon experiment. They will discuss the procedure used to cold test and calibrate the magnicon circuit, and present initial results from experimental operations

  14. The Road Side Unit for the A270 Test Site

    NARCIS (Netherlands)

    Passchier, I.; Driessen, B.J.F.; Heijligers, B.M.R.; Netten, B.D.; Schackmann, P.P.M.

    2011-01-01

    The design and implementation of the Road Side Unit for the A270 Test Site is presented. It consists of a sensor platform and V2I communication platform with full coverage of the test site. A service platform enables applications to make use of these facilities. The RSU will be used both for the

  15. Critical values for unit root tests in seasonal time series

    NARCIS (Netherlands)

    Ph.H.B.F. Franses (Philip Hans); B. Hobijn (Bart)

    1997-01-01

    textabstractIn this paper, we present tables with critical values for a variety of tests for seasonal and non-seasonal unit roots in seasonal time series. We consider (extensions of) the Hylleberg et al. and Osborn et al. test procedures. These extensions concern time series with increasing seasonal

  16. United States nuclear tests, July 1945 through September 1992

    Energy Technology Data Exchange (ETDEWEB)

    1994-12-01

    This document lists chronologically and alphabetically by name all nuclear tests and simultaneous detonations conducted by the United States from July 1945 through September 1992. Several tests conducted during Operation Dominic involved missile launches from Johnston Atoll. Several of these missile launches were aborted, resulting in the destruction of the missile and nuclear device either on the pad or in the air.

  17. Prototype radiographic system for emergency and intensive care units: Initial experience

    International Nuclear Information System (INIS)

    Mirvis, S.

    1986-01-01

    A prototype radiographic system has been developed for use in bedside examinations in multibed trauma or intensive care units and emergency rooms. The system features a single-phase, high-frequency 30-kW ceiling-mounted generator with an x-ray tube extending from a long counterbalanced arm. All movements are servo-assisted for ease of operation. Based on initial experience, the unit allows easier access to the patient around resuscitation and monitoring equipment, occupies less floor space, and yields better quality images than do standard mobile radiographic units

  18. Zeroing and testing units developed for Gerdien atmospheric ion detectors

    International Nuclear Information System (INIS)

    Kolarz, P.; Marinkovic, B.P.; Filipovic, D.M.

    2005-01-01

    Low current measurements in atmospheric ion detection using a Gerdien condenser are subjected to numerous sources of error. Zeroing and testing units described in this article, connected as modules to this type of detector, enable some of these errors to be found and eliminated. The zeroing unit provides digital compensation of the zero drift with a digital sample and hold circuit of 12-bit resolution. It overcomes difficulties related to zero drift and techniques used in the zero conductivity determination when the accelerating potential or airflow rate are zero. The testing unit is a current reference of nominally 10 -12 A intended for testing and correcting the system on current leakage and other measuring deviations due to changes in atmospheric parameters. This unit is an independent battery-powered module, which provides a charge of 10 -12 C per cycle (frequency of order 1 Hz) to the collecting electrode. The control of Gerdien devices is substantially simplified using the zeroing and testing units realized here. Both units are used during 'zero conductivity' regime only

  19. Shakedown Tests for Refurbished and Upgraded Frames and Initiation of Alloy 709 Creep Rupture Tests

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hong [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Moser, Jeremy L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hawkins, Charles S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lara-Curzio, Edgar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-09-01

    This report describes the shakedown tests conducted on the upgraded frames, and initiation of creep rupture tests on refurbished frames. SS316H, a reference material for Alloy 709, was used in shakedown tests, and the tests were conducted at 816 degree C under three stress levels to accumulate 1% creep strain. 1/4” gage diameter specimen design was used. The creep rupture tests on Alloy 709 were initiated at 600 degree C under 330 MPa to target 1,500 h rupture time. 12 specimens with 3/8” gage diameter were prepared from the materials with 6 heat treatment conditions, 2 from each. The required mechanical load under 330MPa was calculated to be 5,286 lb for the 3/8” gage diameter specimen. Among the ART frames, 7 frames are equipped with 10,000 lb load cell including #5 to 8 and #88 to 90, and can be used. 7 tests were thus started in this stage of project, and remaining 5 will be continued whenever any of the 7 tests is completed.

  20. Testing the efficiency of the wine market using unit root tests with sharp and smooth breaks

    Directory of Open Access Journals (Sweden)

    Elie Bouri

    2017-12-01

    Full Text Available This paper examines the efficient market hypothesis for the wine market using a novel unit root test while accounting for sharp shifts and smooth breaks in the monthly data. We find evidence of structural shifts and nonlinearity in the wine indices. Contrary to the results from conventional linear unit root tests, when we account for sharp shifts and smooth breaks, the unit root null for each of the wine indices has been rejected. Overall, our results suggest that the wine market is inefficient when we incorporate breaks. We provide some practical and policy implications of our findings. Keywords: Wine market, Efficiency, Sharp and smooth breaks, Unit root tests

  1. Initial fluid resuscitation of patients with septic shock in the intensive care unit

    DEFF Research Database (Denmark)

    Carlsen, Sarah; Perner, A

    2011-01-01

    Fluid is the mainstay of resuscitation of patients with septic shock, but the optimal composition and volume are unknown. Our aim was to evaluate the current initial fluid resuscitation practice in patients with septic shock in the intensive care unit (ICU) and patient characteristics and outcome...

  2. Polymer coating comprising 2-methoxyethyl acrylate units synthesized by surface-initiated atom transfer radical polymerization

    DEFF Research Database (Denmark)

    2011-01-01

    Source: US2012184029A The present invention relates to preparation of a polymer coating comprising or consisting of polymer chains comprising or consisting of units of 2-methoxyethyl acrylate synthesized by Surface-Initiated Atom Transfer Radical Polymerization (SI ATRP) such as ARGET SI ATRP...

  3. STATIC TESTS OF UNCONVENTIONAL PROPULSION UNITS FOR ULTRALIGHT AIRPLANES

    Directory of Open Access Journals (Sweden)

    Martin Helmich

    2014-06-01

    Full Text Available This paper presents static tests of a new unconventional propulsion unit for small aviation airplanes. Our laboratory stand – a fan drive demonstrator – enables us to compare various design options. We performed experiments to verify the propulsion functionality and a measurement procedure to determine the available thrust of the propulsion unit and its dependence on engine speed. The results used for subsequent optimization include the operating parameters of the propulsion unit, and the temperature and velocity fields in parts of the air duct.

  4. Testing of motor unit synchronization model for localized muscle fatigue.

    Science.gov (United States)

    Naik, Ganesh R; Kumar, Dinesh K; Yadav, Vivek; Wheeler, Katherine; Arjunan, Sridhar

    2009-01-01

    Spectral compression of surface electromyogram (sEMG) is associated with onset of localized muscle fatigue. The spectral compression has been explained based on motor unit synchronization theory. According to this theory, motor units are pseudo randomly excited during muscle contraction, and with the onset of muscle fatigue the recruitment pattern changes such that motor unit firings become more synchronized. While this is widely accepted, there is little experimental proof of this phenomenon. This paper has used source dependence measures developed in research related to independent component analysis (ICA) to test this theory.

  5. Nondestructive test for assembly relationship of initiating explosive device

    International Nuclear Information System (INIS)

    Wang Xiangang; Zhang Chaozong; Guo Zhiping

    2009-01-01

    A 3D computed tomography (CT) method to inspect assembly relationship of initiating explosive device and to nondestructively evaluate assembly relationship by building geometric model from CT images was described. The experiment result proves that this method accurately inspects assembly relationship of initiating explosive device. (authors)

  6. Testing for Turkeys Faith-Based Community HIV Testing Initiative: An Update.

    Science.gov (United States)

    DeGrezia, Mary; Baker, Dorcas; McDowell, Ingrid

    2018-06-04

    Testing for Turkeys (TFT) HIV/hepatitis C virus (HCV) and sexually transmitted infection (STI) testing initiative is a joint effort between Older Women Embracing Life (OWEL), Inc., a nonprofit faith-based community HIV support and advocacy organization; the Johns Hopkins University Regional Partner MidAtlantic AIDS Education and Training Center (MAAETC); and the University of Maryland, Baltimore JACQUES Initiative (JI), and is now in its 11th year of providing HIV outreach, testing, and linkage to care. Since 2008, the annual TFT daylong community HIV testing and linkage to care initiative has been held 2 weeks before Thanksgiving at a faith-based center in Baltimore, Maryland, in a zip code where one in 26 adults and adolescents ages 13 years and older are living with HIV (Maryland Department of Health, Center for HIV Surveillance, Epidemiology, and Evaluation, 2017). TFT includes a health fair with vendors that supply an abundance of education information (handouts, videos, one-on-one counseling) and safer sex necessities, including male and female condoms, dental dams, and lube. Nutritious boxed lunches and beverages are provided to all attendees and volunteers. Everyone tested for HIV who stays to obtain their results is given a free frozen turkey as they exit. The Baltimore City Health Department is on hand with a confidential no-test list (persons in the state already known to have HIV) to diminish retesting of individuals previously diagnosed with HIV. However, linkage to care is available to everyone: newly diagnosed individuals and those previously diagnosed and currently out of care. Copyright © 2018 Association of Nurses in AIDS Care. Published by Elsevier Inc. All rights reserved.

  7. Unit Testing for the Application Control Language (ACL) Software

    Science.gov (United States)

    Heinich, Christina Marie

    2014-01-01

    In the software development process, code needs to be tested before it can be packaged for release in order to make sure the program actually does what it says is supposed to happen as well as to check how the program deals with errors and edge cases (such as negative or very large numbers). One of the major parts of the testing process is unit testing, where you test specific units of the code to make sure each individual part of the code works. This project is about unit testing many different components of the ACL software and fixing any errors encountered. To do this, mocks of other objects need to be created and every line of code needs to be exercised to make sure every case is accounted for. Mocks are important to make because it gives direct control of the environment the unit lives in instead of attempting to work with the entire program. This makes it easier to achieve the second goal of exercising every line of code.

  8. Reactivity initiated accident test series Test RIA 1-4 fuel behavior report

    International Nuclear Information System (INIS)

    Cook, B.A.; Martinson, Z.R.

    1984-09-01

    This report presents and discusses results from the final test in the Reactivity Initiated Accident (RIA) Test Series, Test RIA 1-4, conducted in the Power Burst Facility (PBF) at the Idaho National Engineering Laboratory. Nine preirradiated fuel rods in a 3 x 3 bundle configuration were subjected to a power burst while at boiling water reactor hot-startup system conditions. The test resulted in estimated axial peak, radial average fuel enthalpies of 234 cal/g UO 2 on the center rod, 255 cal/g UO 2 on the side rods, and 277 cal/g UO 2 on the corner rods. Test RIA 1-4 was conducted to investigate fuel coolability and channel blockage within a bundle of preirradiated rods near the present enthalpy limit of 280 cal/g UO 2 established by the US Nuclear Regulatory Commission. The test design and conduct are described, and the bundle and individual rod thermal and mechanical responses are evaluated. Conclusions from this final test and the entire PBF RIA Test Series are presented

  9. Treatability test plan for the 200-ZP-1 operable unit

    International Nuclear Information System (INIS)

    1994-07-01

    This document presents the treatability test plan for pilot-scale pump and treat testing at the 200-ZP-1 Operable Unit. The approach discussed in this treatability test plan is to conduct a pilot-scale pump and treat test for the contaminant plume associated with the 200-ZP-1 Operable Unit. The primary contaminants of concern are carbon tetrachloride, chloroform, and trichloroethylene (TCE). The pilot-scale treatability testing has as its primary purpose to assess the performance of aboveground treatment systems with respect to the ability to remove the primary contaminants present in groundwater withdrawn from the contaminant plume. The overall scope of this test plan includes: description of the pump and treat system to be tested, as well as the test performance objectives and data quality objectives (DQOs) that will be used to evaluate the effectiveness of the pilot-scale treatment system; discussion of the treatment technology to be tested and supporting development activities, including process flow and conceptual design descriptions and equipment, fabrication, utility, and system startup needs; description of pilot-scale treatment system performance, operating procedures, and operational controls, as well as anticipated monitoring activities, analytes, parameters, analytical procedures, and quality assurance protocols; summaries of other related treatability testing elements, including personnel and environmental health and safety controls, process and secondary waste management and disposition, schedule, and program organization

  10. THE MURMANSK INITIATIVE - RF: COMPLETING CONSTRUCTION AND START-UP TESTING

    International Nuclear Information System (INIS)

    CZAJKOWSKI, C.; BOWERMAN, B.S.; DYER, R.S.; SORLIE, A.A.; WESTER, D.

    1998-01-01

    The Murmansk Initiative - RF was instigated to address Russia's ability to meet the London Convention prohibiting ocean dumping of radioactive waste. The Initiative, under a trilateral agreement, will upgrade an existing low-level liquid radioactive waste treatment facility, increasing capacity from 1,200 m 3 /year to 5,000 m 3 /year, and expand the capability to treat liquids containing salt (up to 10 g/L). The three parties to the agreement, the Russian Federation, Norway, and the US, have split the costs for the project. All construction has been provided by Russia. Construction of mechanical systems (piping and valves, pumps, sorbent columns, settling tanks, surge tanks) is nearly complete, with instrumentation and control (I+C) systems the last to be installed. Delays to the I+C installation have occurred because changes in system specifications required some additional US-supplied computer control equipment to be purchased, and clearance through customs (both US and Russian) has been slow. Start-up testing has been limited to testing of some isolated sub-systems because of the delays in I+C installation. Final construction activities are also hampered by the current state of the Russian economy. The specific impact has been completion of the cementation unit, which was not funded under the trilateral agreement (but funded by the Russian government). Russian regulatory authorities have stated that final licensing for expanded capacity (5,000 m 3 /year) will not be given until the cementation unit is on-line

  11. Control room habitability Analysis and Testing for Wolsong Unit 1

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. B. [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    In response to this recommendation, KHNP has established CRH program and performed tracer gas in leakage tests. These activities are described herein including the emergency ventilation system analysis, acceptance criteria calculation for the test and Control Room Envelope (CRE) discrimination, and the results of the tracer gas tests are presented. CRH analysis including unfiltered in leakage tests according to the methodology in ASTM E741 was performed for Wolsong Unit 1. The results show that the integrity of the control room of Wolsong Unit 1 is in good condition to maintain the reactor in a safe condition under accident conditions, which complies with the US NRC regulatory guides 1.78, 1.196 and 1.197.

  12. Construction, commissioning and initial operation of 2400W refrigerator and cold test stand for CDM testing

    International Nuclear Information System (INIS)

    Dubbs, J.D.; Kreinbrink, K.

    1994-01-01

    Air Products and CVI collaborated to design, construct and commission a refrigerator, test stands and integrated control system for the General Dynamics Collider Dipole Magnet Cold Test Facility (CTF) in Hammond, LA. The original project schedule required the cold test facility to be operational within 17 months of the notice to proceed. Midway through the project, changes in General Dynamics magnet testing requirements necessitated doubling the plant capacity, but the on stream date for the initial capacity increment could not be relaxed. The Air Products/CVI team had to adapt the project execution strategy to mitigate the schedule impact of the expansion in a cost effective manner without impacting system functionality, quality or safety. An equally challenging aspect of the job was that the (CTF) was being designed while several major systems that would interface with the CTF were being engineered. General Dynamics, Air Products and CVI had to work very closely to manage the interface issues. The teams efforts were very successful. The Hammond refrigerator/liquifier was started up on schedule. The first two test stands are currently being commissioned and will be on stream just six weeks later than the pre-expansion schedule target and all four test stands will be operational in time to support General Dynamics magnet testing requirements

  13. 77 FR 36014 - Initial Test Program of Emergency Core Cooling Systems for Boiling-Water Reactors

    Science.gov (United States)

    2012-06-15

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0134] Initial Test Program of Emergency Core Cooling... for public comment draft regulatory guide (DG), DG-1277, ``Initial Test Program of Emergency Core..., entitled, ``Initial Test Program of Emergency Core Cooling Systems for Boiling-Water Reactors,'' is...

  14. Semiparametric Power Envelopes for Tests of the Unit Root Hypothesis

    DEFF Research Database (Denmark)

    Jansson, Michael

    This paper derives asymptotic power envelopes for tests of the unit root hypothesis in a zero-mean AR(1) model. The power envelopes are derived using the limits of experiments approach and are semiparametric in the sense that the underlying error distribution is treated as an unknown...

  15. Numerical distribution functions of fractional unit root and cointegration tests

    DEFF Research Database (Denmark)

    MacKinnon, James G.; Nielsen, Morten Ørregaard

    We calculate numerically the asymptotic distribution functions of likelihood ratio tests for fractional unit roots and cointegration rank. Because these distributions depend on a real-valued parameter, b, which must be estimated, simple tabulation is not feasible. Partly due to the presence...

  16. Unit Root Testing in Heteroscedastic Panels Using the Cauchy Estimator

    NARCIS (Netherlands)

    Demetrescu, Matei; Hanck, Christoph

    The Cauchy estimator of an autoregressive root uses the sign of the first lag as instrumental variable. The resulting IV t-type statistic follows a standard normal limiting distribution under a unit root case even under unconditional heteroscedasticity, if the series to be tested has no

  17. Stand tests of the grader unit AKD-2

    Energy Technology Data Exchange (ETDEWEB)

    Kocheskhov, S.M.; Bagley, A.V.; Shalkov, A.V.

    1982-01-01

    Results are presented of stand tests of a static operating grader designed for unmanned extraction of deep beds with programmed control of the unit AKD-2 according to hypsometry of the seam occurrence. Malfunctions in a number of grader assemblies are revealed and eliminated. Parameters are defined which characterize the kinematics and dynamics of the grader mechanism.

  18. Statistical modeling of dental unit water bacterial test kit performance.

    Science.gov (United States)

    Cohen, Mark E; Harte, Jennifer A; Stone, Mark E; O'Connor, Karen H; Coen, Michael L; Cullum, Malford E

    2007-01-01

    While it is important to monitor dental water quality, it is unclear whether in-office test kits provide bacterial counts comparable to the gold standard method (R2A). Studies were conducted on specimens with known bacterial concentrations, and from dental units, to evaluate test kit accuracy across a range of bacterial types and loads. Colony forming units (CFU) were counted for samples from each source, using R2A and two types of test kits, and conformity to Poisson distribution expectations was evaluated. Poisson regression was used to test for effects of source and device, and to estimate rate ratios for kits relative to R2A. For all devices, distributions were Poisson for low CFU/mL when only beige-pigmented bacteria were considered. For higher counts, R2A remained Poisson, but kits exhibited over-dispersion. Both kits undercounted relative to R2A, but the degree of undercounting was reasonably stable. Kits did not grow pink-pigmented bacteria from dental-unit water identified as Methylobacterium rhodesianum. Only one of the test kits provided results with adequate reliability at higher bacterial concentrations. Undercount bias could be estimated for this device and used to adjust test kit results. Insensitivity to methylobacteria spp. is problematic.

  19. Program of in-pile IASCC testing under the simulated actual plant condition. Development of technique for in-pile IASCC initiation test in JMTR

    International Nuclear Information System (INIS)

    Ugachi, Hirokazu; Tsukada, Takashi; Kaji, Yoshiyuki; Nagata, Nobuaki; Dozaki, Koji; Takiguchi, Hideki

    2003-01-01

    Irradiation assisted stress corrosion cracking (IASCC) is caused by the synergistic effects of neutron irradiation, stress and corrosion by high temperature water. It is, therefore, essential to perform in-pile SCC tests, which are material tests under the conditions simulating those of actual LWR operation, in order to clarify the precise mechanism of the phenomenon, though mainly out-of-pile SCC tests for irradiated materials have been carried out in this research field. There are, however, many difficulties to perform in-pile SCC tests. Performing in-pile SCC tests, essential key techniques must be developed. Hence as a part of development of the key techniques for in-pile SCC tests, we have embarked on development of the test technique which enables us to obtain the information concerning the effect of such parameters as applied stress level, water chemistry, irradiation conditions, etc. on the crack initiation behavior. Although it is difficult to detect the crack initiation in in-pile SCC tests, the crack initiation can be evaluated by the detection of specimen rupture if the cross section area of the specimen is small enough. Therefore, we adopted the uniaxial constant loading (UCL) test with small tensile specimens. This paper will describe the current status of the development of several techniques for in-pile SCC initiation tests in JMTR and the results of the performance tests of the designed testing unit using the out-of-pile loop facility. (author)

  20. Initial testing of coated limiters in ISX-B

    International Nuclear Information System (INIS)

    Langley, R.A.; Emerson, L.C.; Whitley, J.B.; Mullendore, A.W.

    1980-01-01

    Low-Z coatings on graphite substrates have been developed for testing as limiters in the Impurity Study Experiment (ISX-B) tokamak. Laboratory and tokamak testings have been accomplished. The laboratory tests included thermal shock experiments by means of pulsed e-beam irradiation, arcing experiments, and hydrogen and xenon ion erosion experiments. The tokamak testing consisted of ohmically heated plasma exposures with energy depositions up to 10 kJ/discharge on the limiters. The coatings, applied by chemical vapor deposition, consisted of TiB 2 and TiC deposited on POCO graphite substrates

  1. United Kingdom evidence on the behaviour of the beta or systematic risk of initial public offerings

    OpenAIRE

    Qian, Yi

    2012-01-01

    This study examines the beta or systematic risk of initial public offerings using a sample of newly issued stocks in the United Kingdom market. The findings are threefold. First, the beta risk estimation is found to decline over time. It corresponds with the differential information model which predicts that the risk of low information is high with uncertainty around it and will decline as the quantity of information increases. The quantity of information, in this case, is represented by time...

  2. The initial validation of a test of emergent literacy

    NARCIS (Netherlands)

    Gruhn, C.M.S.; Weideman, A.J.

    2017-01-01

    In addition to a large body of evidence supporting the relevance of the home environment for literacy development, tests of cognitive-based skills are commonly employed to predict literacy acquisition. The Test of Emergent Literacy (TEL) has been designed to account for the early interaction of

  3. Initial quantitative evaluation of computed radiography in an intensive care unit

    International Nuclear Information System (INIS)

    Hillis, D.J.; McDonald, I.G.; Kelly, W.J.

    1996-01-01

    The first computed radiography (CR) unit in Australia was installed at St Vincent's Hospital, Melbourne, in February 1994. An initial qualitative evaluation of the attitude of the intensive care unit (ICU) physicians to the CR unit was conducted by use of a survey. The results of the survey of ICU physicians indicated that images were available faster than under the previous system and that the use of the CR system was preferred to evaluate chest tubes and line placements. While it is recognized that a further detailed radiological evaluation of the CR system is required to establish the diagnostic performance of CR compared with conventional film, some comments on the implementation of the system and ICU physician attitudes to the CR system are put forward for consideration by other hospitals examining the possible use of CR systems. 11 refs., 1 tab

  4. International cooperative initiatives and the United Nations Framework Convention on Climate Change

    DEFF Research Database (Denmark)

    Bakhtiari, Fatemeh

    2017-01-01

    International cooperative initiatives (ICIs) are multi-country, multi-actor non-state actions that have the potential to reduce emissions of greenhouse gases. The article summarizes the literature on estimates of emission reduction potentials attributed to ICIs. This summary highlights three key ...... efforts under the UNFCCC is uncertain, but believed to be quite large. •The UNFCCC is arguably ill suited to coordinate and strengthen the accountability of international cooperative initiatives.......International cooperative initiatives (ICIs) are multi-country, multi-actor non-state actions that have the potential to reduce emissions of greenhouse gases. The article summarizes the literature on estimates of emission reduction potentials attributed to ICIs. This summary highlights three key...... transparent performance monitoring and reporting mechanisms. The article concludes with two considerations. Firstly, it advocates for the United Nations Environment Programme as one entity that could bring much-needed coordination among ICIs, and between ICIs and national government-led efforts to mitigate...

  5. Systematic Unit Testing in a Read-eval-print Loop

    DEFF Research Database (Denmark)

    Nørmark, Kurt

    2010-01-01

    .  The process of collecting the expressions and their results imposes only little extra work on the programmer.  The use of the tool provides for creation of test repositories, and it is intended to catalyze a much more systematic approach to unit testing in a read-eval-print loop.  In the paper we also discuss...... how to use a test repository for other purposes than testing.  As a concrete contribution we show how to use test cases as examples in library interface documentation.  It is hypothesized---but not yet validated---that the tool will motivate the Lisp programmer to take the transition from casual...

  6. Initial tests on in situ vitrification using electrode feeding techniques

    International Nuclear Information System (INIS)

    Farnsworth, R.K.; Oma, K.H.; Bigelow, C.E.

    1990-05-01

    This report summarizes the results of an engineering-scale in situ vitrification (ISV) test conducted to demonstrate the potential for electrode feeding in soils with a high concentration of metals. The engineering-scale test was part of a Pacific Northwest Laboratory (PNL) program to assist Idaho National Engineering Laboratory (INEL) in conducting treatability studies of the potential for applying ISV to the mixed transuranic waste buried at the INEL subsurface disposal area. The purpose of this test was to evaluate the effectiveness of both gravity fed and operator-controlled electrode feeding in reducing or eliminating many of the potential problems associated with fixed-electrode processing of soils with high concentrations of metal. Actual site soils from INEL were mixed with representative concentrations of carbon steel and stainless steel for this engineering-scale test. 18 refs., 14 figs., 3 tabs

  7. Results of initial nuclear tests on LWBR (LWBR Development Program)

    International Nuclear Information System (INIS)

    Sarber, W.K.

    1979-06-01

    This report presents and discusses the results of physics tests performed at beginning of life on the Light Water Breeder Reactor (LWBR). These tests have confirmed that movable seed assembly critical positions and reactivity worths, temperature coefficients, xenon transient characteristics, core symmetry, and core shutdown are within the range of values used in the design of the LWBR and its reactor protection analysis. Measured core physics parameters were found to be in good agreement with the calculated values

  8. Initial evaluation of an interactive test of sentence gist recognition.

    Science.gov (United States)

    Tye-Murray, N; Witt, S; Castelloe, J

    1996-12-01

    The laser videodisc-based Sentence Gist Recognition (SGR) test consists of sets of topically related sentences that are cued by short film clips. Clients respond to test items by selecting picture illustrations and may interact with the talker by using repair strategies when they do not recognize a test item. The two experiments, involving 40 and 35 adult subjects, respectively, indicated that the SGR may better predict subjective measures of speechreading and listening performance than more traditional audiologic sentence and nonsense syllable tests. Data from cochlear implant users indicated that the SGR accounted for a greater percentage of the variance for selected items of the Communication Profile for the Hearing-Impaired and the Speechreading Questionnaire for Cochlear-Implant Users than two other audiologic tests. As in previous work, subjects were most apt to ask the talker to repeat an utterance that they did not recognize than to ask the talker to restructure it. It is suggested that the SGR may reflect the interactive nature of conversation and provide a simulated real-world listening and/or speechreading task. The principles underlaying this test are consistent with the development of other computer technologies and concepts, such as compact discinteractive and virtual reality.

  9. Personal dosimetry performance testing in the United States

    International Nuclear Information System (INIS)

    Soares, Christopher G.

    2008-01-01

    The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11. Now in it's fourth edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Laboratory Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by U.S. Nuclear Regulatory Commission (NRC) regulations. The U.S. Department of Energy (DOE) also maintains a testing program for its laboratories and contractors, administered by the Department of Energy Laboratory Accreditation Program (DOELAP). One of the goals of this current revision was the modification of ANSI/HPS N13.11 to allow acceptance by both testing programs in order to bring harmonization to U.S. personal dosemeter performance testing. The testing philosophy of ANSI/HPS N13.11 has always combined elements of type testing and routine performance testing and is thus different from the testing philosophy used in the rest of the world. In this paper, the history of performance testing in the U.S. is briefly reviewed. Also described is the revision that produced the fourth edition of this standard, which has taken place over the last three years (2005-2008) by a working group representing national standards laboratories, government laboratories, the military, dosimetry vendors, universities and the nuclear power industry. (author)

  10. Experimental test accelerator: description and results of initial experiments

    International Nuclear Information System (INIS)

    Fessenden, T.; Birx, D.; Briggs, R.

    1980-01-01

    The ETA is a high current (10,000 Amp) linear induction accelerator that produces short (30 ns) pulses of electrons at 5 MeV twice per second or in bursts of 5 pulses separated by as little as one millisecond. At this time the machine has operated at 65% of its design current and 90% of the design voltage. This report contains a description of the accelerator and its diagnostics; the results of the initial year of operation; a comparison of design codes with experiments on beam transport; and a discussion of some of the special problems and their status

  11. Small-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, Garrett N.; Kurath, Dean E.; Buchmiller, William C.; Smith, Dennese M.; Blanchard, Jeremy; Song, Chen; Daniel, Richard C.; Wells, Beric E.; Tran, Diana N.; Burns, Carolyn A.

    2013-05-29

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and net generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of antifoam agents was assessed with most of the simulants. Orifices included round holes and

  12. Initiate test loop irradiations of ALSEP process solvent

    Energy Technology Data Exchange (ETDEWEB)

    Peterman, Dean R. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Olson, Lonnie G. [Idaho National Lab. (INL), Idaho Falls, ID (United States); McDowell, Rocklan G. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-09-01

    This report describes the initial results of the study of the impacts of gamma radiolysis upon the efficacy of the ALSEP process and is written in completion of milestone M3FT-14IN030202. Initial irradiations, up to 100 kGy absorbed dose, of the extraction section of the ALSEP process have been completed. The organic solvent used for these experiments contained 0.05 M TODGA and 0.75 M HEH[EHP] dissolved in n-dodecane. The ALSEP solvent was irradiated while in contact with 3 M nitric acid and the solutions were sparged with compressed air in order to maintain aerated conditions. The irradiated phases were used for the determination of americium and europium distribution ratios as a function of absorbed dose for the extraction and stripping conditions. Analysis of the irradiated phases in order to determine solvent composition as a function of absorbed dose is ongoing. Unfortunately, the failure of analytical equipment necessary for the analysis of the irradiated samples has made the consistent interpretation of the analytical results difficult. Continuing work will include study of the impacts of gamma radiolysis upon the extraction of actinides and lanthanides by the ALSEP solvent and the stripping of the extracted metals from the loaded solvent. The irradiated aqueous and organic phases will be analyzed in order to determine the variation in concentration of solvent components with absorbed gamma dose. Where possible, radiolysis degradation product will be identified.

  13. Maximum likelihood unit rooting test in the presence GARCH: A new test with increased power

    OpenAIRE

    Cook , Steve

    2008-01-01

    Abstract The literature on testing the unit root hypothesis in the presence of GARCH errors is extended. A new test based upon the combination of local-to-unity detrending and joint maximum likelihood estimation of the autoregressive parameter and GARCH process is presented. The finite sample distribution of the test is derived under alternative decisions regarding the deterministic terms employed. Using Monte Carlo simulation, the newly proposed ML t-test is shown to exhibit incre...

  14. Extra-regulatory impact tests and analyses of the structural evaluation test unit

    International Nuclear Information System (INIS)

    Ludwigsen, J.S.; Ammerman, D.J.

    1995-01-01

    The structural evaluation test unit is roughly equivalent to a 1/3 scale model of a high level waste rail cask. The test unit was designed to just meet the requirements of NRC Regulatory Guide 7.6 when subjected to a 9 m (30 ft) free drop resulting in an impact velocity of 13.4 m/s (30 mph) onto an unyielding target in the end-on orientation. The test unit was then subjected to impacts with higher velocities to determine the amount of built-in conservatism in this design approach. Test impacts of 13.4, 20.1 and 26.8 m/s (30, 45, and 60 mph) were performed. This paper will describe the design, testing, and comparison of measured strains and deformations to the equivalent analytical predictions

  15. Small-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, Garrett N.; Kurath, Dean E.; Buchmiller, William C.; Smith, Dennese M.; Blanchard, Jeremy; Song, Chen; Daniel, Richard C.; Wells, Beric E.; Tran, Diana N.; Burns, Carolyn A.

    2012-11-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents was assessed with most of the simulants. Orifices included round holes and

  16. HEAT ENGINEERING TESTING OF AIR COOLING UNIT OF HORIZONTAL TYPE

    OpenAIRE

    Rohachov, Valerii Andriiovych; Semeniako, Oleksandr Volodymyrovych; Лазоренко, Р. О.; Середа, Р. М.; Parafeinyk, Volodymyr Petrovych

    2018-01-01

    The results of the thermal tests of the section of air cooler, the heat-exchange surface of which is made up of chess package of bimetal finned tubes are presented. The methods of research are presented, the experimental stand is described, the measurement errors are given. The efficiency of the experimental stand and the accuracy of the experimental data on it are confirmed. Proposed to use the stand for researches of air cooling units with other types and sections of finned tubes.

  17. Initial Beam Test of the Prototype Strip Line BPM

    International Nuclear Information System (INIS)

    Kwon, Hyeok Jung; Kim, Han Sung; Seol, Kyung Tae; Ryu, Jin Yeong; Jang, Ji Ho; Cho, Yong Sub

    2011-01-01

    A beam position monitor (BPM) was developed which would be used for the Proton Engineering Frontier Project (PEFP) beam line. It is a strip line BPM which is commonly used one for the proton beam. The BPM cross section was designed with the SUPERFISH code and the matching section to the feed through was designed by the MWS code. The design parameters of the BPM are shown in Table 1. The designed BPM was fabricated to verify the manufacturing process and check its electrical performance. After the low power test at the test stand, the BPM was installed at the 20-MeV proton accelerator beam line as shown in Fig. 1

  18. History of personal dosimetry performance testing in the United States

    International Nuclear Information System (INIS)

    Soares, C. G.

    2007-01-01

    The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11 (2001). Now in its third edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by US Nuclear Regulatory Commission (NRC) regulations. The US Dept. of Energy (DOE) also maintains a testing program for its laboratories and contractors, administered by the Dept. of Energy Laboratory Accreditation Program (DOELAP). A focus in recent years has been the modification of ANSI/HPS N13.11 to allow acceptance by both testing programs in order to bring harmonisation to US personal dosemeter processing testing. Since there is no type testing program in the US for personal dosemeters, the testing philosophy of ANSI N13.11 has always combined elements of type testing and routine performance testing. This philosophy is explored in detail in this presentation, along with trends in the development of the document to its present state. In addition, a look will be taken at what the future holds for the next revision of the document, scheduled to begin in 2005. (authors)

  19. Personal dosimetry performance testing in the United States

    International Nuclear Information System (INIS)

    Soares, C.G.

    2005-01-01

    Full text: The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11 (2002). Now in its third edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by US Nuclear Regulatory Commission (NRC) regulations. The US Department of Energy (DOE) also maintains a testing program for its laboratories and contractors, administered by the Department of Energy Laboratory Accreditation Program (DOELAP). A focus in recent years has been the modification of ANSI/HPS N13.11 to allow acceptance by both testing programs in order to bring harmonization to US personal dosimeter processing testing. The testing philosophy of ANSI N13.11 has always combined elements of type testing and routine performance testing and is thus different from the testing philosophy used in the rest of the world. This unique philosophy is explored in detail in this presentation, along with trends in the development of the document to its present state. In addition, a look will be taken at what the future holds for the next revision of the document, scheduled to begin in 2005. (author)

  20. Large-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Schonewill, Philip P.; Gauglitz, Phillip A.; Bontha, Jagannadha R.; Daniel, Richard C.; Kurath, Dean E.; Adkins, Harold E.; Billing, Justin M.; Burns, Carolyn A.; Davis, James M.; Enderlin, Carl W.; Fischer, Christopher M.; Jenks, Jeromy WJ; Lukins, Craig D.; MacFarlan, Paul J.; Shutthanandan, Janani I.; Smith, Dennese M.

    2012-12-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents was assessed with most of the simulants. Orifices included round holes and

  1. Provider initiated HIV testing and counseling, acceptance and ...

    African Journals Online (AJOL)

    admin

    2007-11-29

    Nov 29, 2007 ... Methods: A facility-based cross-sectional quantitative survey was taken from December 1, 2010 to January 10, 2011 among 414 clients coming .... Debre Berhan Referral Hospital has implemented routine. HIV testing for all out .... (died of) HIV and thinking that they can get the virus showed no association ...

  2. Reevaluation of Kori Unit 4 Natural Circulation Test

    Energy Technology Data Exchange (ETDEWEB)

    Yassin, Nassir [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Woo, Sweng Woong [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2013-10-15

    The simulation results showed that the natural circulation flow developed by density difference was capable of removing decay heat from the fuel rod. The maximum pellet centerline temperature of the hot channel showed large margin to the pellet melting temperature. The maximum coolant temperature in the hot channel was well below the saturation temperature. If steam generators provide heat sink to the primary coolant system and thus natural circulation is maintained, the integrity of the fuel in the core can be sustained with large margin. Passive cooling of reactor is inevitable in case of failures in forced cooling system such as loss of electric power for cooling pumps. Fukushima accident showed the importance of the passive core cooling. During the commissioning test of PWRs, natural circulation test is performed to demonstrate the passive core cooling by natural convection. The driving force for coolant flow is developed by the density deference along the loop multiplied by the gravitation. Using the data from 'natural circulation test' and 'RCS flow coast down test' of Kori Unit 4, fuel behavior was reevaluated by FRAPTRAN code. RCS natural circulation test of Kori Unit 4 was reevaluated by FRAPTYRAN simulation to study the fuel behavior during the flow coast down transient and at the equilibrium condition in which decay heat transport and RCS flow were stabilized.

  3. Initial SVE Well Testing for the A-Area Miscellaneous Rubble Pile (ARP) Trenches Area

    International Nuclear Information System (INIS)

    RIHA, BRIAN

    2004-01-01

    The A-Area Miscellaneous Rubble Pile (ARP) is a 5.9 acre unit located at the southern end of A/M Area at the Savannah River Site (SRS). Disposal activities at ARP began in the early 1950s. The exact dates of operation and material disposed in the unit remain unknown. Within the ARP exists a smaller, approximately 2 acre, sub unit identified as the Trenches Area. The Trenches Area is dominated by a T-shaped trench (approximately 50 feet wide) containing 8 to 12 feet of ash material. This T-shaped trench will be referred to as the ARP Trench. Vegetation has been removed from the Trenches Area and a lower permeability earthen cover now covers the ARP Trench. The ARP active soil vapor extraction (ASVE) remediation system consists of seven extraction wells and twelve monitoring wells that were pushed into the vadose zone of the ARP Trench. The remediation system was designed based on the pre-design study conducted in 2002. The purpose of the initial soil vapor extraction (SVE) well testing was to verify the integrity and functionality of the nineteen wells installed in the ARP Trench. The well integrity was evaluated based on the flow rate, vacuum, and indication that soil gas and not surface air was pulled from the well. Soil gas was defined as gas with levels of carbon dioxide (CO2) above ambient concentrations (400-700 ppmv). Volatile organic compound (VOC) concentrations were measured at each well to determine the initial distribution of the contamination. In addition, the subsurface vacuum distribution was measured around each extraction well as a relative measure of the influence of each well

  4. An Initiating-Event Analysis for PSA of Hanul Units 3 and 4: Results and Insights

    International Nuclear Information System (INIS)

    Kim, Dong-San; Park, Jin Hee

    2015-01-01

    As a part of the PSA, an initiating-event (IE) analysis was newly performed by considering the current state of knowledge and the requirements of the ASME/ANS probabilistic risk assessment (PRA) standard related to IE analysis. This paper describes the methods of, results and some insights from the IE analysis for the PSA of the Hanul units 3 and 4. In this study, as a part of the PSA for the Hanul units 3 and 4, an initiating-event (IE) analysis was newly performed by considering the current state of knowledge and the requirements of the ASME/ANS probabilistic risk assessment (PRA) standard. In comparison with the previous IE analysis, this study performed a more systematic and detailed analysis to identify potential initiating events, and calculated the IE frequencies by using the state-of-the-art methods and the latest data. As a result, not a few IE frequencies are quite different from the previous frequencies, which can change the major accident sequences obtained from the quantification of the PSA model

  5. 24 CFR 245.417 - Initial submission of materials to HUD: Conversion of residential units to a nonresidential use...

    Science.gov (United States)

    2010-04-01

    ... HUD: Conversion of residential units to a nonresidential use, or to cooperative housing or... Covered Action § 245.417 Initial submission of materials to HUD: Conversion of residential units to a nonresidential use, or to cooperative housing or condominiums. In the case of a conversion of residential units...

  6. A clinical audit of provider-initiated HIV counselling and testing in a ...

    African Journals Online (AJOL)

    Background. Early initiation of antiretroviral therapy reduces transmission of HIV and prolongs life. Expansion of HIV testing is therefore pivotal in overcoming the HIV pandemic. Provider-initiated counselling and testing (PICT) at first clinical contact is one way of increasing the number of individuals tested. Our impression is ...

  7. Initial Tests on First Full-size Endcap Crystals

    CERN Document Server

    Davies, Gavin; Lecoq, Paul; Marcos, Roger; Schneegans, Marc; Sempere-Roldan, P

    1999-01-01

    At the end of last year the first full size ECAL endcap crystals were delivered to CERN.Thirty in number, they were produced to the final geometrical specifications; 220mm long with a rear square face of 30mm and a front square face of 28.6mm. All were de livered polished. The visual inspection, dimension, transmission, light yield and light yield uniformity tests carried out since are discussed, with particular emphasis on the light yield uniformity. The results are very encouraging.

  8. Operation of the radioactive acid digestion test unit

    International Nuclear Information System (INIS)

    Blasewitz, A.G.; Allen, C.R.; Lerch, R.E.; Ely, P.C.; Richardson, G.L.

    1980-01-01

    The Radioactive Acid Digestion Test Unit (RADTU) has been constructed at Hanford to demonstrate the application of the Acid Digestion Process for treating combustible transuranic wastes and scrap materials. The RADTU with its original tray digestion vessel has recently completed a six-month campaign processing potentially contaminated nonglovebox wastes from a Hanford plutonium facility. During this campaign, it processed 2100 kg of largely cellulosic wastes at an average sustained processing rate of 3 kg/h as limited by the water boiloff rate from the acid feeds. The on-line operating efficiency was nearly 50% on a twelve hour/day, five day/week basis. Following this campaign, a new annular high rate digester has been installed for testing. In preliminary tests with simulated wastes, the new digester demonstrated a sustained capacity of 10 kg/h with greatly improved intimacy of contact between the digestion acid and the waste. The new design also doubles the heat transfer surface, which with reduced heat loss area, is expected to provide at least three times the water boiloff rate of the previous tray digester design. Following shakedown testing with simulated and low-level wastes, the new unit will be used to process combustible plutonium scrap and waste from Hanford plutonium facilities for the purposes of volume reduction, plutonium recovery, and stabilization of the final waste form

  9. WTP Waste Feed Qualification: Glass Fabrication Unit Operation Testing Report

    Energy Technology Data Exchange (ETDEWEB)

    Stone, M. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Hanford Missions Programs; Newell, J. D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Process Technology Programs; Johnson, F. C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Engineering Process Development; Edwards, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL). Engineering Process Development

    2016-07-14

    The waste feed qualification program is being developed to protect the Hanford Tank Waste Treatment and Immobilization Plant (WTP) design, safety basis, and technical basis by assuring waste acceptance requirements are met for each staged waste feed campaign prior to transfer from the Tank Operations Contractor to the feed receipt vessels inside the Pretreatment Facility. The Waste Feed Qualification Program Plan describes the three components of waste feed qualification: 1. Demonstrate compliance with the waste acceptance criteria 2. Determine waste processability 3. Test unit operations at laboratory scale. The glass fabrication unit operation is the final step in the process demonstration portion of the waste feed qualification process. This unit operation generally consists of combining each of the waste feed streams (high-level waste (HLW) and low-activity waste (LAW)) with Glass Forming Chemicals (GFCs), fabricating glass coupons, performing chemical composition analysis before and after glass fabrication, measuring hydrogen generation rate either before or after glass former addition, measuring rheological properties before and after glass former addition, and visual observation of the resulting glass coupons. Critical aspects of this unit operation are mixing and sampling of the waste and melter feeds to ensure representative samples are obtained as well as ensuring the fabrication process for the glass coupon is adequate. Testing was performed using a range of simulants (LAW and HLW simulants), and these simulants were mixed with high and low bounding amounts of GFCs to evaluate the mixing, sampling, and glass preparation steps in shielded cells using laboratory techniques. The tests were performed with off-the-shelf equipment at the Savannah River National Laboratory (SRNL) that is similar to equipment used in the SRNL work during qualification of waste feed for the Defense Waste Processing Facility (DWPF) and other waste treatment facilities at the

  10. Phased Startup Initiative Phase 3 Test Procedure (OCRWM)

    International Nuclear Information System (INIS)

    PAJUNEN, A.L.

    2000-01-01

    The purpose of this test procedure is to safely operate the Fuel Retrieval System (FRS) and Integrated Water Treatment System (IWTS) with specific fuel canisters, and show that canisters containing fuel can be retrieved from the canister queue, decapped in the Canister Decapper, loaded into the Primary Clean Machine (PCM) for fuel cleaning, fuel sorted on the Process Table, then loaded back into fuel canisters and relocated in Basin Storage. Additional Data are collected during this test, beyond that collected during production operations. These data support qualifying the cleaning performance of the PCM, assessing the quantity of scrap generated during the cleaning, and evaluating the impact of fuel retrieval operations on the Basin water quality. The additional data collected primarily consist of weighing fuel and scrap at selected points in the operation, as well as photographing fuel and scrap as it is processed. The time to perform operations is also monitored for comparison with design predictions. Water quality data are collected to establish a base line to predict the effectiveness of equipment design for control of contamination and visibility during production operation

  11. Phased Startup Initiative Phase 3 and 4 Test Procedure (OCRWM)

    International Nuclear Information System (INIS)

    PAJUNEN, A.L.

    2000-01-01

    The purpose of this test procedure is to safely operate the Fuel Retrieval System (FRS) and Integrated Water Treatment System (IWTS) with specific fuel canisters, and show that canisters containing fuel can be retrieved from the canister queue, decapped in the Canister Decapper, and loaded into the Primary Clean Machine (PCM) for fuel cleaning; and that fuel can be sorted on the Process Table, then loaded back into fuel canisters and relocated in basin storage. An option is included to load selected elements into multi-canister overpack (MCO) Fuel Baskets. Additional Data are collected during this test, beyond that collected during production operations. These data support qualifying the cleaning performance of the PCM, assessing the quantity of scrap generated during the cleaning, and evaluating the impact of fuel retrieval operations on the Basin water quality. The additional data collected primarily consist of weighing fuel and scrap at selected points in the operation, as well as photographing fuel and scrap as it is processed. The time to perform operations is also monitored for comparison with design predictions. Water quality data are collected to establish a baseline to predict the effectiveness of equipment design for control of contamination and visibility during production operation

  12. Alien species recorded in the United Arab Emirates: an initial list of terrestrial and freshwater species

    Directory of Open Access Journals (Sweden)

    Pritpal Soorae

    2015-10-01

    Full Text Available Little is documented on the alien terrestrial and freshwater species in the United Arab Emirates. To address this, an assessment of terrestrial and freshwater alien species was conducted using various techniques such as a questionnaire, fieldwork data, networking with relevant people, and a detailed literature review. The results of the initial assessment show that there are 146 alien species recorded in the following seven major taxonomic groups: invertebrates 49 species, freshwater fish five species, amphibian one species, reptiles six species, birds 71 species, mammals six species and plants eight species. To inform decision makers a full list of the 146 species identified in this assessment is presented. 

  13. Reflood behavior at low initial clad temperature in Slab Core Test Facility Core-II

    International Nuclear Information System (INIS)

    Akimoto, Hajime; Sobajima, Makoto; Abe, Yutaka; Iwamura, Takamichi; Ohnuki, Akira; Okubo, Tsutomu; Murao, Yoshio; Okabe, Kazuharu; Adachi, Hiromichi.

    1990-07-01

    In order to study the reflood behavior with low initial clad temperature, a reflood test was performed using the Slab Core Test Facility (SCTF) with initial clad temperature of 573 K. The test conditions of the test are identical with those of SCTF base case test S2-SH1 (initial clad temperature 1073 K) except the initial clad temperature. Through the comparison of results from these two tests, the following conclusions were obtained. (1) The low initial clad temperature resulted in the low differential pressures through the primary loops due to smaller steam generation in the core. (2) The low initial clad temperature caused the accumulated mass in the core to be increased and the accumulated mass in the downcomer to be decreased in the period of the lower plenum injection with accumulator (before 50s). In the later period of the cold leg injection with LPCI (after 100s), the water accumulation rates in the core and the downcomer were almost the same between both tests. (3) The low initial clad temperature resulted in the increase of the core inlet mass flow rate in the lower plenum injection period. However, the core inlet mass flow rate was almost the same regardless of the initial clad temperature in the later period of the cold leg injection period. (4) The low initial clad temperature resulted in the low turnaround temperature, high temperature rise and fast bottom quench front propagation. (5) In the region apart from the quench front, low initial clad temperature resulted in the lower heat transfer. In the region near the quench front, almost the same heat transfer coefficient was observed between both tests. (6) No flow oscillation with a long period was observed in the SCTF test with low initial clad temperature of 573 K, while it was remarkable in the Cylindrical Core Test Facility (CCTF) test which was performed with the same initial clad temperature. (J.P.N.)

  14. Initial tests of a prototype MRI-compatible PET imager

    International Nuclear Information System (INIS)

    Raylman, Raymond R.; Majewski, Stan; Lemieux, Susan; Velan, S. Sendhil; Kross, Brain; Popov, Vladimir; Smith, Mark F.; Weisenberger, Andrew G.; Wojcik, Randy

    2006-01-01

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI, will allow the correlation of form with function. Our group (a collaboration of West Virginia University and Jefferson Lab) is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode with an active FOV of 5x5x4 cm 3 . Each MRI-PET detector module consists of an array of LSO detector elements (2.5x2.5x15 mm 3 ) coupled through a long fiber optic light guide to a single Hamamatsu flat panel PSPMT. The fiber optic light guide is made of a glued assembly of 2 mm diameter acrylic fibers with a total length of 2.5 m. The use of a light guides allows the PSPMTs to be positioned outside the bore of the 3 T General Electric MRI scanner used in the tests. Photon attenuation in the light guides resulted in an energy resolution of ∼60% FWHM, interaction of the magnetic field with PSPMT further reduced energy resolution to ∼85% FWHM. Despite this effect, excellent multi-plane PET and MRI images of a simple disk phantom were acquired simultaneously. Future work includes improved light guides, optimized magnetic shielding for the PSPMTs, construction of specialized coils to permit high-resolution MRI imaging, and use of the system to perform simultaneous PET and MRI or MR-spectroscopy

  15. Initial tests of a prototype MRI-compatible PET imager

    Energy Technology Data Exchange (ETDEWEB)

    Raylman, Raymond R. [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States)]. E-mail: rraylman@wvu.edu; Majewski, Stan [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Lemieux, Susan [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States); Velan, S. Sendhil [Center for Advanced Imaging, Department of Radiology, West Virginia University, HSB Box 9236, Morgantown, WV (United States); Kross, Brain [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Popov, Vladimir [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Smith, Mark F. [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Weisenberger, Andrew G. [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Wojcik, Randy [Detector Group, Physics Division, Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2006-12-20

    Multi-modality imaging is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET fused with anatomical structure images created by MRI, will allow the correlation of form with function. Our group (a collaboration of West Virginia University and Jefferson Lab) is developing a system to acquire MRI and PET images contemporaneously. The prototype device consists of two opposed detector heads, operating in coincidence mode with an active FOV of 5x5x4 cm{sup 3}. Each MRI-PET detector module consists of an array of LSO detector elements (2.5x2.5x15 mm{sup 3}) coupled through a long fiber optic light guide to a single Hamamatsu flat panel PSPMT. The fiber optic light guide is made of a glued assembly of 2 mm diameter acrylic fibers with a total length of 2.5 m. The use of a light guides allows the PSPMTs to be positioned outside the bore of the 3 T General Electric MRI scanner used in the tests. Photon attenuation in the light guides resulted in an energy resolution of {approx}60% FWHM, interaction of the magnetic field with PSPMT further reduced energy resolution to {approx}85% FWHM. Despite this effect, excellent multi-plane PET and MRI images of a simple disk phantom were acquired simultaneously. Future work includes improved light guides, optimized magnetic shielding for the PSPMTs, construction of specialized coils to permit high-resolution MRI imaging, and use of the system to perform simultaneous PET and MRI or MR-spectroscopy.

  16. Testing for purchasing power parity in 21 African countries using several unit root tests

    Science.gov (United States)

    Choji, Niri Martha; Sek, Siok Kun

    2017-04-01

    Purchasing power parity is used as a basis for international income and expenditure comparison through the exchange rate theory. However, empirical studies show disagreement on the validity of PPP. In this paper, we conduct the testing on the validity of PPP using panel data approach. We apply seven different panel unit root tests to test the validity of the purchasing power parity (PPP) hypothesis based on the quarterly data on real effective exchange rate for 21 African countries from the period 1971: Q1-2012: Q4. All the results of the seven tests rejected the hypothesis of stationarity meaning that absolute PPP does not hold in those African Countries. This result confirmed the claim from previous studies that standard panel unit tests fail to support the PPP hypothesis.

  17. Restart Testing Program for piping following steam generator replacement at North Anna Unit 1

    International Nuclear Information System (INIS)

    Bain, R.A.; Bayer, R.K.

    1993-01-01

    In order to provide assurance that the effects of performing steam generator replacement (SGR) at North Anna unit 1 had no adverse impact on plant piping systems, a cold functional verification restart testing program was developed. This restart testing program was implemented in lieu of a hot functional testing program normally used during the initial startup of a nuclear plant. A review of North Anna plant-specific and generic U.S. Nuclear Regulatory Commission requirements for restart testing was performed to ensure that no mandatory hot functional testing was required. This was determined to be the case, and the development of a cold functional test program was initiated. The cold functional test had inherent advantages as compared to the hot functional testing, while still providing assurance of piping system adequacy. The advantages of the cold verification program included reducing risk to personnel from hot piping, increasing the accuracy of measurements with the improvement in work conditions, eliminating engineering activities during the heatup process, and being able to record measurements as construction work was completed allowing for rework or repair of components if required. To ensure the effectiveness of the cold verification program, a project procedure was generated to identify the personnel, equipment, and measurement requirements. An engineering calculation was issued to document the scope of the restart test program, and an additional calculation was developed to provide acceptance criteria for the critical commodity measurements

  18. Sublimator Driven Coldplate Engineering Development Unit Test Results

    Science.gov (United States)

    Sheth, Rubik B.; Stephan, Ryan A.; Leimkuehler, Thomas O.

    2010-01-01

    The Sublimator Driven Coldplate (SDC) is a unique piece of thermal control hardware that has several advantages over a traditional thermal control scheme. The principal advantage is the possible elimination of a pumped fluid loop, potentially increasing reliability and reducing complexity while saving both mass and power. Because the SDC requires a consumable feedwater, it can only be used for short mission durations. Additionally, the SDC is ideal for a vehicle with small transport distances and low heat rejection requirements. An SDC Engineering Development Unit was designed and fabricated. Performance tests were performed in a vacuum chamber to quantify and assess the performance of the SDC. The test data was then used to develop correlated thermal math models. Nonetheless, an Integrated Sublimator Driven Coldplate (ISDC) concept is being developed. The ISDC couples a coolant loop with the previously described SDC hardware. This combination allows the SDC to be used as a traditional coldplate during long mission phases and provides for dissimilar system redundancy

  19. Initial evaluation of children admitted on the Paediatric Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Esperanza Arce Delgado

    2007-09-01

    Full Text Available The initial evaluation of the child, when admitted on the Paediatric Intensive Unit, is a essential tool and key piece as a starting point on the development of a specific Care Plan for each child. Therefore, it is necessary the existence of a protocol, according to a rigorous methodology, so that cares will have quality and thus, it will be avoided that each nursing professional will act in a different way, according to his intuition, beliefs or improvisation capacity.The initial evaluation of the child will allow us not only to coordinate the interventions, but also to give continuity to the cares.The initial evaluation of the child document is a nursing register that is part of the clinical register of the paediatric patient. Nursing registers turn to be the best approximation of what nowadays is our job’s practice, and they are, therefore, necessary for us to be judged by a professional perspective and to make it possible to classify the services we carry out to the society.

  20. Canada-United States-Mexico Trilateral Cooperation on Childhood Obesity Initiative

    Directory of Open Access Journals (Sweden)

    Cristina Rabadán-Diehl

    Full Text Available ABSTRACT Childhood obesity is an important public health problem that affects countries in the Americas. In 2014, Pan American Health Organization (PAHO Member States agreed on a Plan of Action for the Prevention of Obesity in Children and Adolescents in an effort to address the impact of this disorder in the Americas region. The interventions laid out in this regional plan are multi-faceted and require multi-sectoral partnerships. Building on a strong history of successful trilateral collaboration, Canada, Mexico, and the United States formed a partnership to address the growing epidemic of childhood obesity in the North American region. This collaborative effort, known as the Trilateral Cooperation on Childhood Obesity Initiative, is the first initiative in the region to address chronic noncommunicable diseases by bringing together technical and policy experts, with strong leadership and support from the secretaries and ministers of health. The Initiative’s goals include increasing levels of physical activity and reducing sedentary behavior through 1 increased social mobilization and citizen engagement, 2 community- based outreach, and 3 changes to the built (man-made environment. This article describes the background and development process of the Initiative; specific goals, activities, and actions achieved to date; and opportunities and next steps. This information may be useful for those forming other partnerships designed to address childhood obesity or other complex public health challenges in the region.

  1. Test procedures, AN/AIC-27 system and component units. [for space shuttle

    Science.gov (United States)

    Reiff, F. H.

    1975-01-01

    The AN/AIC-27 (v) intercommunication system is a 30-channel audio distribution which consists of: air crew station units, maintenance station units, and a central control unit. A test procedure for each of the above units and also a test procedure for the system are presented. The intent of the test is to provide data for use in shuttle audio subsystem design.

  2. 30 CFR 74.5 - Tests of coal mine dust personal sampler units.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests of coal mine dust personal sampler units... Personal Sampler Unit § 74.5 Tests of coal mine dust personal sampler units. (a) The National Institute for... tests and evaluations to determine whether the pump unit of a CMDPSU that is submitted for approval...

  3. An Investigation into the Cost of Unit Testing on an Embedded System

    OpenAIRE

    Qiu, Wensi

    2011-01-01

    The quality of embedded software is important, especially for life-critical and mission-critical embedded systems. And software testing is a key activity to ensure the quality of embedded software. Both system testing and unit testing are vital to test embedded software. Unit testing is probably more important to ensure there are no latent faults. System testing is almost invariably done on a target system, but unit testing is normally done on a host system, as standard test frame...

  4. Full scale dynamic testing of Kozloduy NPP unit 5 structures

    International Nuclear Information System (INIS)

    Da Rin, E.M.

    1999-01-01

    As described in this report, the Kozloduy NPP western site has been subjected to low level earthquake-like ground shaking - through appropriately devised underground explosions - and the resulting dynamic response of the NPP reactor Unit 5 important structures appropriately measured and digitally recorded. In-situ free-field response was measured concurrently more than 100 m aside the main structures of interest. The collected experimental data provide reference information on the actual dynamic characteristics of the Kozloduy NPPs main structures, as well as give some useful indications on the dynamic soil-structure interaction effects for the case of low level excitation. Performing the present full-scale dynamic structural testing activities took advantage of the experience gained by ISMES during similar tests, lately performed in Italy and abroad (in particular, at the Paks NPP in 1994). The IAEA promoted dynamic testing of the Kozloduy NPP Unit 5 by means of pertinently designed buried explosion-induced ground motions which has provided a large amount of data on the dynamic structural response of its major structures. In the present report, the conducted investigation is described and the acquired digital data presented. A series of preliminary analyses were undertaken for examining in detail the ground excitation levels that were produced by these weak earthquake simulation experiments, as well as for inferring some structural characteristics and behaviour information from the collected data. These analyses ascertained the high quality of the collected digital data. Presumably due to soil-structure dynamic interaction effects, reduced excitation levels were observed at the reactor building foundation raft level with respect to the concurrent free-field ground motions. measured at a 140 m distance from the reactor building centre. Further more detailed and systematic analyses are worthwhile to be performed for extracting more complete information about the

  5. Initial assessment of jaundice in otherwise healthy infants--a comparison of methods in two postnatal units.

    LENUS (Irish Health Repository)

    Allen, N M

    2012-02-01

    Transcutaneous bilirubin (TcB) has the potential to reduce total serum bilirubin (TS) sampling. The principal aim of this study was to determine and compare the number of initial TSB samples (TSBs) in two postnatal units (hospitals A & B) whereby hospital A used TcB and hospital B did not. A secondary aim was to determine the clinical factors that led to initial TSBs exceeding exchange transfusion level in both hospitals. Results demonstrated both hospitals had similar populations and patient numbers following selection criteria. 1645 neonates (10.4%) had one or more TSBs performed in hospital A, versus 2373 neonates (15.1%) in hospital B (p < 0.01). Fourteen neonates in hospital A and 3 neonates in hospital B had initial TSBs above exchange transfusion level. For neonates with TSBs above exchange, preventable factors related to earlier testing and follow up. In routine clinical practice, TcB is associated with a significantly reduced number of TSB measurements. TSB levels above exchange transfusion are linked to preventable factors, in otherwise healthy neonates.

  6. Healthy hospital food initiatives in the United States: time to ban sugar sweetened beverages to reduce childhood obesity

    OpenAIRE

    Wojcicki, Janet M

    2013-01-01

    While childhood obesity is a global problem, the extent and severity of the problem in United States, has resulted in a number of new initiatives, including recent hospital initiatives to limit the sale of sweetened beverages and other high calorie drinks in hospital vending machines and cafeterias. These proposed policy changes are not unique to United States, but are more comprehensive in the number of proposed hospitals that they will impact. Meanwhile, however, it is advised, that these i...

  7. Initiation and continuation of long-acting reversible contraception in the United States military healthcare system.

    Science.gov (United States)

    Chiles, Daniel P; Roberts, Timothy A; Klein, David A

    2016-09-01

    Long-acting reversible contraception is more effective for pregnancy prevention than shorter-acting contraceptive methods and has the potential to reduce healthcare disparities and costs. However, long-acting reversible contraception is underused in the United States. One population of interest is beneficiaries of the United States military healthcare system who have access to universal healthcare, including no-cost, no-copay contraception with unlimited method switching, and comprise a large, actual use cohort. Efforts to increase long-acting reversible contraception initiation and continuation in this population may improve health outcomes and mitigate the profound consequences of unintended or mistimed pregnancy on readiness and cost to the military. We aimed to determine long-acting reversible contraception initiation and continuation rates among the diverse population with universal healthcare who are enrolled in the US military healthcare system. This study is a retrospective cohort of >1.7 million women, aged 14-40 years, who were enrolled in the US military healthcare system, TRICARE Prime, between October 2009 and September 2014. Individuals were assessed for long-acting reversible contraception initiation and continuation with the use of medical billing records. Method continuation and factors that were associated with early method discontinuation were evaluated with the Kaplan-Meier estimator and Cox proportional hazard models. During the study dates, 188,533 women initiated long-acting reversible contraception. Of these, 74.6% women selected intrauterine contraceptives. Method initiation rates remained relatively stable (41.7-50.1/1000 women/year) for intrauterine methods, although the rate for subdermal implants increased from 6.1-23.0/1000 women/year. In analysis of women who selected intrauterine contraceptives, 61.2% continued their method at 36 months, and 48.8% continued at 60 months. Among women who selected the implant, 32.0% continued their

  8. Experimental data report for test TS-3 Reactivity Initiated Accident test in the NSRR with pre-irradiated BWR fuel rod

    International Nuclear Information System (INIS)

    Nakamura, Takehiko; Yoshinaga, Makio; Fujishiro, Toshio; Kobayashi, Shinsho; Yamahara, Takeshi; Sukegawa, Tomohide; Kikuchi, Teruo; Sobajima, Makoto.

    1993-09-01

    This report presents experimental data for Test TS-3 which was the third test in a series of Reactivity Initiated Accident (RIA) tests using pre-irradiated BWR fuel rods, performed in the Nuclear Safety Research Reactor (NSRR) in September, 1990. Test fuel rod used in the Test TS-3 was a short-sized BWR (7 x 7) type rod which was re-fabricated from a commercial rod irradiated in the Tsuruga Unit 1 power reactor of Japan Atomic Power Co. The fuel had an initial enrichment of 2.79 % and a burnup of 26 Gwd/tU. A pulse irradiation of the test fuel rod was performed under a cooling condition of stagnant water at atmospheric pressure and at ambient temperature which simulated a BWR's cold start-up RIA event. The energy deposition of the fuel rod in this test was evaluated to be 94 ± 4 cal/g · fuel (88 ± 4 cal/g · fuel in peak fuel enthalpy) and no fuel failure was observed. Descriptions on test conditions, test procedures, transient behavior of the test rod during the pulse irradiation, and results of pre-pulse and post-pulse irradiation examinations are described in this report. (author)

  9. Red blood cell-derived microparticles isolated from blood units initiate and propagate thrombin generation.

    Science.gov (United States)

    Rubin, Olivier; Delobel, Julien; Prudent, Michel; Lion, Niels; Kohl, Kid; Tucker, Erik I; Tissot, Jean-Daniel; Angelillo-Scherrer, Anne

    2013-08-01

    Red blood cell-derived microparticles (RMPs) are small phospholipid vesicles shed from RBCs in blood units, where they accumulate during storage. Because microparticles are bioactive, it could be suggested that RMPs are mediators of posttransfusion complications or, on the contrary, constitute a potential hemostatic agent. This study was performed to establish the impact on coagulation of RMPs isolated from blood units. Using calibrated automated thrombography, we investigated whether RMPs affect thrombin generation (TG) in plasma. We found that RMPs were not only able to increase TG in plasma in the presence of a low exogenous tissue factor (TF) concentration, but also to initiate TG in plasma in absence of exogenous TF. TG induced by RMPs in the absence of exogenous TF was neither affected by the presence of blocking anti-TF nor by the absence of Factor (F)VII. It was significantly reduced in plasma deficient in FVIII or F IX and abolished in FII-, FV-, FX-, or FXI-deficient plasma. TG was also totally abolished when anti-XI 01A6 was added in the sample. Finally, neither Western blotting, flow cytometry, nor immunogold labeling allowed the detection of traces of TF antigen. In addition, RMPs did not comprise polyphosphate, an important modulator of coagulation. Taken together, our data show that RMPs have FXI-dependent procoagulant properties and are able to initiate and propagate TG. The anionic surface of RMPs might be the site of FXI-mediated TG amplification and intrinsic tenase and prothrombinase complex assembly. © 2012 American Association of Blood Banks.

  10. Fabrication and testing history prototypes and production units

    Energy Technology Data Exchange (ETDEWEB)

    1954-09-01

    From April, 1951 to Aug, 1954, New York Shipbuilding Corp. carried out a subcontract with E.I. du Pont de Nemours & Company that was without parallel in the shipyard`s history. The work, designated the NYX Project for reasons of security, was vital to the operations of the Savannah River Plant, Aiken, S.C., which was then being designed and constructed by du Pont for the Atomic Energy Commission. It consisted of three broad parts: developmental and experimental work; fabrication and testing of a prototype unit; fabrication of production units. Five production units were ultimately built, one of them converted from the prototype. All were fabricated from stainless steel, and involved welding techniques, control of thermal distortion and tolerances never previously attempted on assemblies of comparable size. Du Pont`s technical experience and the background of New York Ship in heavy construction, particularly in the fabrication of naval gun turrets, were combined from the outset to resolve the difficult fabrication problems that occurred almost daily. Representatives of both companies worked together as a team in the shops and at supervisory levels to an unprecedented extent. The report is intended primarily to summarize New York Ship`s part in the project, but also includes some of du Pont`s activities since the work of the two organizations was so interrelated. Because of the scope of the program, it will not always be possible to provide detailed information, but rather to record what happened in general terms. Where the reader desires more specific data, he should refer to original plans and records, including various reports compiled during the course of the project.

  11. 40 CFR Table 19 to Subpart Uuu of... - Initial Compliance With Organic HAP Emission Limits for Catalytic Reforming Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Initial Compliance With Organic HAP Emission Limits for Catalytic Reforming Units 19 Table 19 to Subpart UUU of Part 63 Protection of... HAP Emission Limits for Catalytic Reforming Units As stated in § 63.1566(b)(7), you shall meet each...

  12. 40 CFR Table 12 to Subpart Uuu of... - Initial Compliance With Organic HAP Emission Limits for Catalytic Cracking Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Initial Compliance With Organic HAP Emission Limits for Catalytic Cracking Units 12 Table 12 to Subpart UUU of Part 63 Protection of... HAP Emission Limits for Catalytic Cracking Units As stated in § 63.1565(b)(4), you shall meet each...

  13. Radioactive acid digestion test unit nonradioactive startup operations

    International Nuclear Information System (INIS)

    Allen, C.R.; Cowan, R.G.; Crippen, M.D.; Divine, J.R.

    1978-05-01

    The Radioactive Acid Digestion Test Unit (RADTU) will process 5 kg/hour of combustible solid waste and is designed to handle almost all solid combustible waste found in plutonium processing with plutonium contamination levels up to scrap. The RADTU is designed with special safety features to safely contain high masses of fissile materials and to safely handle unusual materials and reactive chemicals which may find their way into the waste. Nonradioactive operating experience to date has been very satisfactory. RADTU has been operated for extended runs on both a 24-hour per day basis as well as on a one shift per day basis. Some minor operating problems have been encountered as expected in a shakedown operation. In general, solutions to these have been readily found. 12 figures

  14. Initiation of depleted uranium oxide and spent fuel testing for the spent fuel sabotage aerosol ratio programme

    International Nuclear Information System (INIS)

    Molecke, M.A.; Gregson, M.W.; Sorenson, K.B.

    2004-01-01

    We provide a detailed overview of an on-going, multinational test programme that is developing aerosol data for some spent fuel sabotage scenarios on spent fuel transport and storage casks. Experiments are being performed to quantify the aerosolised materials plus volatilised fission products generated from actual spent fuel and surrogate material test rods, due to impact by a high-energy/density device. The programme participants in the United States plus Germany, France and the United Kingdom, part of the international Working Group for Sabotage Concerns of Transport and Storage Casks (WGSTSC) have strongly supported and coordinated this research programme. Sandia National Laboratories has the lead role for conducting this research programme; test programme support is provided by both the US Department of Energy and the US Nuclear Regulatory Commission. We provide a summary of the overall, multiphase test design and a description of all explosive containment and aerosol collection test components used. We focus on the recently initiated tests on 'surrogate' spent fuel, unirradiated depleted uranium oxide and forthcoming actual spent fuel tests. We briefly summarise similar results from completed surrogate tests that used non-radioactive, sintered cerium oxide ceramic pellets in test rods. (author)

  15. Sector activities and lessons learned around initial implementation of the United States national physical activity plan.

    Science.gov (United States)

    Evenson, Kelly R; Satinsky, Sara B

    2014-08-01

    National plans are increasingly common but infrequently evaluated. The 2010 United States National Physical Activity Plan (NPAP) provided strategies to increase population levels of physical activity. This paper describes (i) the initial accomplishments of the NPAP sector teams, and (ii) results from a process evaluation to determine how the sectors operated, their cross-sector collaboration, challenges encountered, and positive experiences. During 2011, a quarterly reporting system was developed to capture sector-level activities. A year-end interview derived more detailed information. Interviews with 12 sector leads were recorded, transcribed verbatim, and analyzed for common themes. The 6 sectors worked on goals from the implementation plan that focused broadly on education, promotion, intervention, policy, collaboration, and evaluation. Through year-end interviews, themes were generated around operations, goal setting, and cross-sector collaboration. Challenges to the NPAP work included lack of funding and time, the need for marketing and promotion, and organizational support. Positive experiences included collaboration, efficiency of work, enhanced community dynamic, and accomplishments toward NPAP goals. These initial results on the NPAP sector teams can be used as a baseline assessment for future monitoring. The lessons learned may be useful to other practitioners developing evaluations around state- or national-level plans.

  16. 40 CFR Table 5 to Subpart Uuu of... - Initial Compliance With Metal HAP Emission Limits for Catalytic Cracking Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Initial Compliance With Metal HAP Emission Limits for Catalytic Cracking Units 5 Table 5 to Subpart UUU of Part 63 Protection of Environment..., Subpt. UUU, Table 5 Table 5 to Subpart UUU of Part 63—Initial Compliance With Metal HAP Emission Limits...

  17. 40 CFR Table 33 to Subpart Uuu of... - Initial Compliance With HAP Emission Limits for Sulfur Recovery Units

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Initial Compliance With HAP Emission Limits for Sulfur Recovery Units 33 Table 33 to Subpart UUU of Part 63 Protection of Environment..., Subpt. UUU, Table 33 Table 33 to Subpart UUU of Part 63—Initial Compliance With HAP Emission Limits for...

  18. Smoking Initiation Among Young Adults in the United States and Canada, 1998-2010: A Systematic Review

    OpenAIRE

    Freedman, Kit S.; Nelson, Nanette M.; Feldman, Laura L.

    2011-01-01

    Introduction Young adults have the highest smoking rate of any age group in the United States and Canada, and recent data indicate that they often initiate smoking as young adults. The objective of this study was to systematically review peer-reviewed articles on cigarette smoking initiation and effective prevention efforts among young adults. Methods We searched 5 databases for research articles published in English between 1998 and 2010 on smoking initiation among young adults (aged 18-25) ...

  19. Advanced Motor Control Test Facility for NASA GRC Flywheel Energy Storage System Technology Development Unit

    Science.gov (United States)

    Kenny, Barbara H.; Kascak, Peter E.; Hofmann, Heath; Mackin, Michael; Santiago, Walter; Jansen, Ralph

    2001-01-01

    This paper describes the flywheel test facility developed at the NASA Glenn Research Center with particular emphasis on the motor drive components and control. A four-pole permanent magnet synchronous machine, suspended on magnetic bearings, is controlled with a field orientation algorithm. A discussion of the estimation of the rotor position and speed from a "once around signal" is given. The elimination of small dc currents by using a concurrent stationary frame current regulator is discussed and demonstrated. Initial experimental results are presented showing the successful operation and control of the unit at speeds up to 20,000 rpm.

  20. CFL Labeling Harmonization in the United States, China, Brazil andELI Member Countries: Specifications, Testing, and MutualRecognition

    Energy Technology Data Exchange (ETDEWEB)

    Fridley, David; Lin, Jiang; Denver, Andrea; Biermayer, Peter; Dillavou, Tyler

    2005-07-20

    This report examines critical differences among energy-efficient labeling programs for CFLs in Brazil, China, the United States, and the seven members of the international Efficient Lighting Initiative (ELI) in terms of technical specifications and test procedures, and review issues related to international harmonization of these standards.

  1. Working on a Standard Joint Unit: A pilot test.

    Science.gov (United States)

    Casajuana, Cristina; López-Pelayo, Hugo; Mercedes Balcells, María; Miquel, Laia; Teixidó, Lídia; Colom, Joan; Gual, Antoni

    2017-09-29

    Assessing cannabis consumption remains complex due to no reliable registration systems. We tested the likelihood of establishing a Standard Joint Unit (SJU) which considers the main cannabinoids with implication on health through a naturalistic approach.  Methodology. Pilot study with current cannabis users of four areas of Barcelona: universities, nightclubs, out-patient mental health service, and cannabis associations. We designed and administered a questionnaire on cannabis use-patterns and determined the willingness to donate a joint for analysis. Descriptive statistics were used to analyze the data. Forty volunteers answered the questionnaire (response rate 95%); most of them were men (72.5%) and young adults (median age 24.5 years; IQR 8.75 years) who consume daily or nearly daily (70%). Most participants consume marihuana (85%) and roll their joints with a median of 0.25 gr of marihuana. Two out of three (67.5%) stated they were willing to donate a joint. Obtaining an SJU with the planned methodology has proved to be feasible. Pre-testing resulted in an improvement of the questionnaire and retribution to incentivize donations. Establishing an SJU is essential to improve our knowledge on cannabis-related outcomes.

  2. Near Earth Asteroid Solar Sail Engineering Development Unit Test Program

    Science.gov (United States)

    Lockett, Tiffany Russell; Few, Alexander; Wilson, Richard

    2017-01-01

    The Near Earth Asteroid (NEA) Scout project is a 30x20x10cm (6U) cubesat reconnaissance mission to investigate a near Earth asteroid utilizing an 86m2 solar sail as the primary propulsion system. This will be the largest solar sail NASA will launch to date. NEA Scout is a secondary payload currently manifested on the maiden voyage of the Space Launch System in 2018. In development of the solar sail subsystem, design challenges were identified and investigated for packaging within a 6U form factor and deployment in cis-lunar space. Analysis furthered understanding of thermal, stress, and dynamics of the stowed system and matured an integrated sail membrane model for deployed flight dynamics. This paper will address design, fabrication, and lessons learned from the NEA Scout solar sail subsystem engineering development unit. From optical properties of the sail material to folding and spooling the single 86m2 sail, the team has developed a robust deployment system for the solar sail. This paper will also address expected and received test results from ascent vent, random vibration, and deployment tests.

  3. Fission Surface Power Technology Demonstration Unit Test Results

    Science.gov (United States)

    Briggs, Maxwell H.; Gibson, Marc A.; Geng, Steven M.; Sanzi, James L.

    2016-01-01

    The Fission Surface Power (FSP) Technology Demonstration Unit (TDU) is a system-level demonstration of fission power technology intended for use on manned missions to Mars. The Baseline FSP systems consists of a 190 kWt UO2 fast-spectrum reactor cooled by a primary pumped liquid metal loop. This liquid metal loop transfers heat to two intermediate liquid metal loops designed to isolate fission products in the primary loop from the balance of plant. The intermediate liquid metal loops transfer heat to four Stirling Power Conversion Units (PCU), each of which produce 12 kWe (48 kW total) and reject waste heat to two pumped water loops, which transfer the waste heat to titanium-water heat pipe radiators. The FSP TDU simulates a single leg of the baseline FSP system using an electrically heater core simulator, a single liquid metal loop, a single PCU, and a pumped water loop which rejects the waste heat to a Facility Cooling System (FCS). When operated at the nominal operating conditions (modified for low liquid metal flow) during TDU testing the PCU produced 8.9 kW of power at an efficiency of 21.7 percent resulting in a net system power of 8.1 kW and a system level efficiency of 17.2 percent. The reduction in PCU power from levels seen during electrically heated testing is the result of insufficient heat transfer from the NaK heater head to the Stirling acceptor, which could not be tested at Sunpower prior to delivery to the NASA Glenn Research Center (GRC). The maximum PCU power of 10.4 kW was achieved at the maximum liquid metal temperature of 875 K, minimum water temperature of 350 K, 1.1 kg/s liquid metal flow, 0.39 kg/s water flow, and 15.0 mm amplitude at an efficiency of 23.3 percent. This resulted in a system net power of 9.7 kW and a system efficiency of 18.7 percent.

  4. Potential impact on HIV incidence of higher HIV testing rates and earlier antiretroviral therapy initiation in MSM

    DEFF Research Database (Denmark)

    Phillips, Andrew N; Cambiano, Valentina; Miners, Alec

    2015-01-01

    count 350/μl. We investigated what would be required to reduce HIV incidence in MSM to below 1 per 1000 person-years (i.e. cost-effective. METHODS: A dynamic, individual-based simulation model was calibrated to multiple data sources...... with viral suppression to 80%, and it would be 90%, if ART is initiated at diagnosis. The scenarios required for such a policy to be cost-effective are presented. CONCLUSION: This analysis provides targets for the proportion of all HIV-positive MSM with viral suppression required to achieve substantial......BACKGROUND: Increased rates of testing, with early antiretroviral therapy (ART) initiation, represent a key potential HIV-prevention approach. Currently, in MSM in the United Kingdom, it is estimated that 36% are diagnosed by 1 year from infection, and the ART initiation threshold is at CD4 cell...

  5. A Test Set for stiff Initial Value Problem Solvers in the open source software R: Package deTestSet

    NARCIS (Netherlands)

    Mazzia, F.; Cash, J.R.; Soetaert, K.

    2012-01-01

    In this paper we present the R package deTestSet that includes challenging test problems written as ordinary differential equations (ODEs), differential algebraic equations (DAEs) of index up to 3 and implicit differential equations (IDES). In addition it includes 6 new codes to solve initial value

  6. 40 CFR 62.14720 - What information must I submit following my initial performance test?

    Science.gov (United States)

    2010-07-01

    ... report for the initial performance test results obtained under § 62.14660, as applicable. (b) The values... fabric filter to comply with the emission limitations, documentation that a bag leak detection system has...

  7. Plant Outage Time Savings Provided by Subcritical Physics Testing at Vogtle Unit 2

    International Nuclear Information System (INIS)

    Cupp, Philip; Heibel, M.D.

    2006-01-01

    The most recent core reload design verification physics testing done at Southern Nuclear Company's (SNC) Vogtle Unit 2, performed prior to initial power operations in operating cycle 12, was successfully completed while the reactor was at least 1% ΔK/K subcritical. The testing program used was the first application of the Subcritical Physics Testing (SPT) program developed by the Westinghouse Electric Company LLC. The SPT program centers on the application of the Westinghouse Subcritical Rod Worth Measurement (SRWM) methodology that was developed in cooperation with the Vogtle Reactor Engineering staff. The SRWM methodology received U. S. Nuclear Regulatory Commission (NRC) approval in August of 2005. The first application of the SPT program occurred at Vogtle Unit 2 in October of 2005. The results of the core design verification measurements obtained during the SPT program demonstrated excellent agreement with prediction, demonstrating that the predicted core characteristics were in excellent agreement with the actual operating characteristics of the core. This paper presents an overview of the SPT Program used at Vogtle Unit 2 during operating cycle 12, and a discussion of the critical path outage time savings the SPT program is capable of providing. (authors)

  8. Corrective Action Plan for Corrective Action Unit 543: Liquid Disposal Units, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    NSTec Environmental Restoration

    2006-01-01

    Corrective Action Unit (CAU) 543, Liquid Disposal Units, is listed in Appendix III of the Federal Facility Agreement and Consent Order of 1996. CAU 543 consists of seven Corrective Action Sites (CASs) located in Areas 6 and 15 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. CAU 543 consists of the following seven CASs: (sm b ullet) CAS 06-07-01, Decon Pad (sm b ullet) CAS 15-01-03, Aboveground Storage Tank (sm b ullet) CAS 15-04-01, Septic Tank (sm b ullet) CAS 15-05-01, Leachfield (sm b ullet) CAS 15-08-01, Liquid Manure Tank (sm b ullet) CAS 15-23-01, Underground Radioactive Material Area (sm b ullet) CAS 15-23-03, Contaminated Sump, Piping From January 24, 2005 through April 14, 2005, CAU 543 site characterization activities were conducted, and are reported in Appendix A of the CAU 543 Corrective Action Decision Document (CADD) (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2005). The recommended corrective action as stated in the approved CADD is No Further Action for five of the CAU 543 CASs, and Closure In Place for the remaining two CASs

  9. Closure Report for Corrective Action Unit 543: Liquid Disposal Units, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Environmental Restoration

    2008-01-01

    This Closure Report (CR) documents closure activities for Corrective Action Unit (CAU) 543, Liquid Disposal Units, according to the Federal Facility Agreement and Consent Order (FFACO, 1996) and the Corrective Action Plan (CAP) for CAU 543 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2007). CAU 543 is located at the Nevada Test Site (NTS), Nevada (Figure 1), and consists of the following seven Corrective Action Sites (CASs): CAS 06-07-01, Decon Pad; CAS 15-01-03, Aboveground Storage Tank; CAS 15-04-01, Septic Tank; CAS 15-05-01, Leachfield; CAS 15-08-01, Liquid Manure Tank; CAS 15-23-01, Underground Radioactive Material Area; CAS 15-23-03, Contaminated Sump, Piping; and CAS 06-07-01 is located at the Decontamination Facility in Area 6, adjacent to Yucca Lake. The remaining CASs are located at the former U.S. Environmental Protection Agency (EPA) Farm in Area 15. The purpose of this CR is to provide a summary of the completed closure activities, to document waste disposal, and to present analytical data confirming that the remediation goals were met. The closure alternatives consisted of closure in place for two of the CASs, and no further action with implementation of best management practices (BMPs) for the remaining five CASs.

  10. 29 CFR 1919.73 - Unit proof test and examination of derricks.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Unit proof test and examination of derricks. 1919.73 Section 1919.73 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... Devices § 1919.73 Unit proof test and examination of derricks. (a) Unit proof tests of derricks shall be...

  11. 200-BP-5 operable unit treatability test report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-01

    The 200-BP-5 Operable Unit was established in response to recommendations presented in the 200 East Groundwater Aggregate Area Management Study Report (AAMSR) (DOE-RL 1993a). Recognizing different approaches to remediation, the groundwater AAMSR recommended separating groundwater from source and vadose zone operable units and subdividing 200 East Area groundwater into two operable units. The division between the 200-BP-5 and 200-PO-1 Operable Units was based principally on source operable unit boundaries and distribution of groundwater plumes derived from either B Plant or Plutonium/Uranium Extraction (PUREX) Plant liquid waste disposal sites.

  12. 200-BP-5 operable unit treatability test report

    International Nuclear Information System (INIS)

    1996-04-01

    The 200-BP-5 Operable Unit was established in response to recommendations presented in the 200 East Groundwater Aggregate Area Management Study Report (AAMSR) (DOE-RL 1993a). Recognizing different approaches to remediation, the groundwater AAMSR recommended separating groundwater from source and vadose zone operable units and subdividing 200 East Area groundwater into two operable units. The division between the 200-BP-5 and 200-PO-1 Operable Units was based principally on source operable unit boundaries and distribution of groundwater plumes derived from either B Plant or Plutonium/Uranium Extraction (PUREX) Plant liquid waste disposal sites

  13. Smoking initiation among young adults in the United States and Canada, 1998-2010: a systematic review.

    Science.gov (United States)

    Freedman, Kit S; Nelson, Nanette M; Feldman, Laura L

    2012-01-01

    Young adults have the highest smoking rate of any age group in the United States and Canada, and recent data indicate that they often initiate smoking as young adults. The objective of this study was to systematically review peer-reviewed articles on cigarette smoking initiation and effective prevention efforts among young adults. We searched 5 databases for research articles published in English between 1998 and 2010 on smoking initiation among young adults (aged 18-25) living in the United States or Canada. We extracted the following data from each study selected: the measure of initiation used, age range of initiation, age range of study population, data source, target population, sampling method, and sample size. We summarized the primary findings of each study according to 3 research questions and categories of data (eg, sociodemographic) that emerged during the data extraction process. Of 1,072 identified studies, we found 27 articles that met our search criteria, but several included a larger age range of initiation (eg, 18-30, 18-36) than we initially intended to include. Disparities in young adult smoking initiation existed according to sex, race, and educational attainment. The use of alcohol and illegal drugs was associated with smoking initiation. The risk of smoking initiation among young adults increased under the following circumstances: exposure to smoking, boredom or stress while serving in the military, attending tobacco-sponsored social events while in college, and exposure to social norms and perceptions that encourage smoking. Effective prevention efforts include exposure to counter-marketing, denormalization campaigns, taxation, and the presence of smoke-free policies. Much remains to be learned about young adult smoking initiation, particularly among young adults in the straight-to-work population. Dissimilar measures of smoking initiation limit our knowledge about smoking initiation among young adults. We recommend developing a standardized

  14. United States position paper on sodium fires, design and testing

    International Nuclear Information System (INIS)

    Hilliard, R.K.; Johnson, R.P.

    1983-01-01

    The first Specialists' Meeting on sodium fire technology sponsored by the International Working Group on Fast Reactors (IWGFR) was held in Richland, Washington in 1972. The group concluded that the state-of-technology at that time was inadequate to support the growing LMFBR industry. During the second IWGFR Specialists' Meeting on sodium fires, held in Cadarache, France in 1978, a large quantity of technical information was exchanged and areas were identified where additional work was needed. Advances in several important areas of sodium fire technology have been made in the United States since that time, including improved computer codes, design of a sodium fire protection system for the CRBRP, measurement of water release from heated concrete, and testing and modeling of the sodium-concrete reaction. Research in the U.S. related to sodium fire technology is performed chiefly at the Energy Systems Group of Rockwell International (including Atomics International), the Hanford Engineering Development Laboratory (HEDL), and the Sandia National Laboratories (SNL). The work at the first two laboratories is sponsored by the U.S. Department of Energy, while that at the latter is sponsored by the U.S. Nuclear Regulatory Commission. Various aspects of sodium fire related work is also performed at several other laboratories. The current status of sodium fire technology in the U.S. is summarized in this report

  15. Results of zinc injection test for Hamaoka Unit-1

    International Nuclear Information System (INIS)

    Kani, K.; Masuda, H.; Hayashi, Y.; Sudo, S.; Yamazaki, K.

    1998-01-01

    A zinc injection test was preformed at Hamaoka Nuclear Power Station Unit-1 for suppressing radiation dose rate on primary coolant recirculation piping after the replacement of piping. Zinc ion was injected by using injection system where Depleted Zinc Oxide was dissolved in carbonated water. Controllability of the system was sufficient to maintain concentration of zinc in primary water. The concentration of zinc in the primary coolant was controlled from 1 ppb to 5 ppb gradually. The increasing trend of concentration of Co-60 in the coolant was suppressed at zinc concentration of 3 ppb. It is evaluated that the deposition coefficient of Co-60 onto the surface of primary coolant recirculation piping was suppressed to one-third of previous cycle in average, and one-fourth of that just before injection start at zinc concentration of 5 ppb. We concluded that zinc injection is effective for suppressing dose rate on the primary coolant piping and no adverse effect occurs by zinc injection up to 5 ppb in the primary coolant. (J.P.N.)

  16. HIPAA, HIPAA, Hooray?: Current Challenges and Initiatives in Health Informatics in the United States.

    Science.gov (United States)

    Joshi, Sanjaya

    2008-01-01

    A review of the current challenges, trends and initiatives around the various regulations as related to Health Informatics in the United States is presented. A summary of the functions in a workflow-based approach organized into the process and compliance for HIPAA, secure email and fax communications interfaces, e-prescriptions and patient safety and the health information technology savings claims versus costs follows: HIPAA compliance is complex; data interoperability and integration remains difficult.Email and faxing is possible with current over-the-shelf technologies within the purview of the HIPAA Security and Privacy rule.Integration of e-prescribing and NPI data is an area where health informatics can make a real difference.Medical errors remain high.There are no real savings yet from the usage of health information technologies; the costs for implementation remain high, and the business model has not evolved to meet the needs.Health Information Technology (Health IT) projects continue to have a significant failure rate; Open Source technologies are a viable alternative both for cost reduction and scalability. A discussion on the macro view of health informatics is also presented within the context of healthcare models and a comparison of the U.S. system against other countries.

  17. Initial Assessment of Parallelization of Monte Carlo Calculation using Graphics Processing Units

    International Nuclear Information System (INIS)

    Choi, Sung Hoon; Joo, Han Gyu

    2009-01-01

    Monte Carlo (MC) simulation is an effective tool for calculating neutron transports in complex geometry. However, because Monte Carlo simulates each neutron behavior one by one, it takes a very long computing time if enough neutrons are used for high precision of calculation. Accordingly, methods that reduce the computing time are required. In a Monte Carlo code, parallel calculation is well-suited since it simulates the behavior of each neutron independently and thus parallel computation is natural. The parallelization of the Monte Carlo codes, however, was done using multi CPUs. By the global demand for high quality 3D graphics, the Graphics Processing Unit (GPU) has developed into a highly parallel, multi-core processor. This parallel processing capability of GPUs can be available to engineering computing once a suitable interface is provided. Recently, NVIDIA introduced CUDATM, a general purpose parallel computing architecture. CUDA is a software environment that allows developers to manage GPU using C/C++ or other languages. In this work, a GPU-based Monte Carlo is developed and the initial assessment of it parallel performance is investigated

  18. Barriers and facilitators to implementing the Baby-Friendly hospital initiative in neonatal intensive care units.

    Science.gov (United States)

    Benoit, Britney; Semenic, Sonia

    2014-01-01

    To explore manager, educator, and clinical leader perceptions of barriers and facilitators to implementing Baby-Friendly practice in the neonatal intensive care unit (NICU). Qualitative, descriptive design. Two university-affiliated level-III NICUs in Canada. A purposive sample of 10 medical and nursing managers, nurse educators, lactation consultants, and neonatal nurse practitioners. In-depth, semistructured interviews transcribed and analyzed using qualitative content analysis. Participants valued breastfeeding and family-centered care yet identified numerous contextual barriers to Baby-Friendly care including infant health status, parent/infant separation, staff workloads and work patterns, gaps in staff knowledge and skills, and lack of continuity of breastfeeding support. Facilitators included breastfeeding education, breastfeeding champions, and interprofessional collaboration. Despite identifying numerous barriers, participants recognized the potential value of expanding the Baby-Friendly Hospital Initiative (BFHI) to the NICU setting. Recommendations include promoting BFHI as a facilitator of family-centered care, interdisciplinary staff education, increasing access to lactation consultants, and establishing a group of NICU champions dedicated to BFHI implementation. © 2014 AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses.

  19. HIPAA, HIPAA, Hooray? Current Challenges and Initiatives in Health Informatics in the United States

    Directory of Open Access Journals (Sweden)

    Sanjaya Joshi

    2008-01-01

    Full Text Available A review of the current challenges, trends and initiatives around the various regulations as related to Health Informatics in the United States is presented.A summary of the functions in a workflow-based approach organized into the process and compliance for HIPAA, secure email and fax communications interfaces, e-prescriptions and patient safety and the health information technology savings claims versus costs follows: * HIPAA compliance is complex; data interoperability and integration remains difficult. * Email and faxing is possible with current over-the-shelf technologies within the purview of the HIPAA Security and Privacy rule. * Integration of e-prescribing and NPI data is an area where health informatics can make a real difference. * Medical errors remain high. * There are no real savings yet from the usage of health information technologies; the costs for implementation remain high, and the business model has not evolved to meet the needs. * Health Information Technology (Health IT projects continue to have a significant failure rate; Open Source technologies are a viable alternative both for cost reduction and scalability.A discussion on the macro view of health informatics is also presented within the context of healthcare models and a comparison of the U.S. system against other countries.

  20. Corrective Action Plan for Corrective Action Unit 543: Liquid Disposal Units, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    NSTec Environmental Restoration

    2007-01-01

    Corrective Action Unit (CAU) 543: Liquid Disposal Units is listed in Appendix III of the ''Federal Facility Agreement and Consent Order'' (FFACO) which was agreed to by the state of Nevada, the U.S. Department of Energy (DOE), and the U.S. Department of Defense (FFACO, 1996). CAU 543 sites are located in Areas 6 and 15 of the Nevada Test Site (NTS), which is approximately 65 miles northwest of Las Vegas, Nevada. CAU 543 consists of the following seven Corrective Action Sites (CASs) (Figure 1): CAS 06-07-01, Decon Pad; CAS 15-01-03, Aboveground Storage Tank; CAS 15-04-01, Septic Tank; CAS 15-05-01, Leachfield; CAS 15-08-01, Liquid Manure Tank; CAS 15-23-01, Underground Radioactive Material Area; and CAS 15-23-03, Contaminated Sump, Piping. All Area 15 CASs are located at the former U.S. Environmental Protection Agency (EPA) Farm, which operated from 1963 to 1981 and was used to support animal experiments involving the uptake of radionuclides. Each of the Area 15 CASs, except CAS 15-23-01, is associated with the disposal of waste effluent from Building 15-06, which was the primary location of the various tests and experiments conducted onsite. Waste effluent disposal from Building 15-06 involved piping, sumps, outfalls, a septic tank with leachfield, underground storage tanks, and an aboveground storage tank (AST). CAS 15-23-01 was associated with decontamination activities of farm equipment potentially contaminated with radiological constituents, pesticides, and herbicides. While the building structures were removed before the investigation took place, all the original tanks, sumps, piping, and concrete building pads remain in place. The Area 6 CAS is located at the Decontamination Facility in Area 6, a facility which operated from 1971 to 2001 and was used to decontaminate vehicles, equipment, clothing, and other materials that had become contaminated during nuclear testing activities. The CAS includes the effluent collection and distribution systems for Buildings

  1. Moving the Barricades to Physical Activity: A Qualitative Analysis of Open Streets Initiatives Across the United States.

    Science.gov (United States)

    Eyler, Amy A; Hipp, J Aaron; Lokuta, Julie

    2015-01-01

    Ciclovía, or Open Streets initiatives, are events where streets are opened for physical activity and closed to motorized traffic. Although the initiatives are gaining popularity in the United States, little is known about planning and implementing them. The goals of this paper are to explore the development and implementation of Open Streets initiatives and make recommendations for increasing the capacity of organizers to enhance initiative success. Phenomenology with qualitative analysis of structured interviews was used. Study setting was urban and suburban communities in the United States. Study participants were organizers of Open Streets initiatives in U.S. cities. Using a list of 47 events held in 2011, 27 lead organizers were interviewed by telephone about planning, implementation, and lessons learned. The interviews were digitally recorded and transcribed. A phenomenologic approach was used, an initial coding tool was developed after reviewing a sample of transcripts, and constant comparative coding methodology was applied. Themes and subthemes were generated from codes. The most common reasons for initiation were to highlight or improve health and transportation. Most initiatives aimed to reach the general population, but some targeted families, children, or specific neighborhoods. Getting people to understand the concept of Open Streets was an important challenge. Other challenges included lack of funding and personnel, and complex logistics. These initiatives democratize public space for citizens while promoting physical activity, social connectedness, and other broad agendas. There are opportunities for the research community to contribute to the expanse and sustainability of Open Streets, particularly in evaluation and dissemination.

  2. Heat balance calculation and feasibility analysis for initial startup of Fuqing nuclear turbine unit with non-nuclear steam

    International Nuclear Information System (INIS)

    He Liu; Xiao Bo; Song Yumeng

    2014-01-01

    Non-nuclear steam run up compared with nuclear steam run up, can verify the design, manufacture, installation quality of the unit, at the same time shorten the follow-up duration of the entire group ready to start debugging time. In this paper, starting from the first law of thermodynamics, Analyzed Heat balance Calculation and Feasibility analysis for Initial startup of Fuqing nuclear Turbine unit with Non-nuclear steam, By the above calculation, to the system requirements and device status on the basis of technical specifications, confirmed the feasibility of Non-nuclear steam running up in theory. After the implementation of the Non-nuclear turn of Fuqing unit, confirmed the results fit with the actual process. In summary, the Initial startup of Fuqing turbine unit with Non-nuclear steam is feasible. (authors)

  3. Provider-initiated HIV counselling and testing (PICT) in the mentally ill

    African Journals Online (AJOL)

    This paper discusses provider-initiated HIV counselling and testing (PICT) and some of the ethical dilemmas associated with it, on the basis that PICT may be used to increase the number of mentally ill persons tested for HIV. The authors conclude that PICT should be promoted to all psychiatric admissions and mentally ill ...

  4. Learning From Tests: Facilitation of Delayed Recall by Initial Recognition Alternatives.

    Science.gov (United States)

    Whitten, William B., II; Leonard, Janet Mauriello

    1980-01-01

    Two experiments were designed to determine the effects of multiple-choice recognition test alternatives on subsequent memory for the correct answers. Results of both experiments are interpreted as demonstrations of the principle that long-term retention is facilitated such that memory evaluation occurs during initial recognition tests. (Author/RD)

  5. Novel Field test design and initial result for AC and DC characterization for PV-panels

    DEFF Research Database (Denmark)

    Thorsteinsson, Sune; Riedel, Nicholas; Santamaria Lancia, Adrian Alejo

    This work describes the design and initial test results of a field test for PV modules, where the PV modules the majority of the time operates to produce power at their maximum power point. Sequentially the individual modules are switched into a measurement circuitry for IV curves and impedance s...

  6. M109 Family of Vehicles, Paladin Integrated Management (PIM): Operational Assessment of the Initial Operational Test and Evaluation (IOT and E)

    Science.gov (United States)

    2017-01-01

    Director, Operational Test and Evaluation M109 Family of Vehicles, Paladin Integrated Management (PIM) Operational Assessment of the... operational suitability, test adequacy, and survivability of the M109 Family of Vehicles (FoV), known as Paladin Integrated Management (PIM) Self...prevent the M109A7 SPH-equipped unit from completing its mission. The Paladin Integrated Management (PIM) Initial Operational Test and Evaluation

  7. Analysis of the rock mechanics properties of volcanic tuff units from Yucca Mountain, Nevada Test Site

    International Nuclear Information System (INIS)

    Price, R.H.

    1983-08-01

    Over two hundred fifty mechanical experiments have been run on samples of tuff from Yucca Mountain, Nevada Test Site. Cores from the Topopah Spring, Calico Hills, Bullfrog and Tram tuff units were deformed to collect data for an initial evaluation of mechanical (elastic and strength) properties of the potential horizons for emplacement of commercial nuclear wastes. The experimental conditions ranged in sample saturation from room dry to fully saturated, confining pressure from 0.1 to 20 MPa, pore pressure from 0.1 to 5 MPa, temperature from 23 to 200 0 C, and strain rate from 10 -7 to 10 -2 s -1 . These test data have been analyzed for variations in elastic and strength properties with changes in test conditions, and to study the effects of bulk-rock characteristics on mechanical properties. In addition to the site-specific data on Yucca Mountain tuff, mechanical test results on silicic tuff from Rainier Mesa, Nevada Test Site, are also discussed. These data both overlap and augment the Yucca Mountain tuff data, allowing more definitive conclusions to be reached, as well as providing data at some test conditions not covered by the site-specific tests

  8. Groundwater Monitoring Report Central Nevada Test Area, Corrective Action Unit 443

    Energy Technology Data Exchange (ETDEWEB)

    None

    2008-04-01

    This report presents the 2007 groundwater monitoring results collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) for the Central Nevada Test Area (CNTA) Corrective Action Unit (CAU) 443. Responsibility for the environmental site restoration of the CNTA was transferred from the DOE Office of Environmental Management (DOE-EM) to DOE-LM on October 1, 2006. Requirements for CAU 443 are specified in the Federal Facility Agreement and Consent Order (FFACO 2005) entered into by DOE, the U.S. Department of Defense, and the State of Nevada and includes groundwater monitoring in support of site closure. This is the first groundwater monitoring report prepared by DOE-LM for the CNTA The CNTA is located north of U.S. Highway 6, approximately 30 miles north of Warm Springs in Nye County, Nevada (Figure 1). Three emplacement boreholes, UC-1, UC-3, and UC-4, were drilled at the CNTA for underground nuclear weapons testing. The initial underground nuclear test, Project Faultless, was conducted in borehole UC-1 at a depth of 3,199 feet (ft) (975 meters) below ground surface on January 19, 1968. The yield of the Project Faultless test was estimated to be 0.2 to 1 megaton (DOE 2004). The test resulted in a down-dropped fault block visible at land surface (Figure 2). No further testing was conducted at the CNTA, and the site was decommissioned as a testing facility in 1973.

  9. 10 CFR 430.24 - Units to be tested.

    Science.gov (United States)

    2010-01-01

    ... this section, for each basic model 1 of conventional cooking tops, conventional ovens and microwave...-registered professional engineer who is not an employee of the manufacturer. The registered professional... consumption of the unit(s). The manufacturer is to keep the registered professional engineer's certifications...

  10. THE GERMLINE STEM CELL NICHE UNIT IN MAMMALIAN TESTES

    Science.gov (United States)

    Oatley, Jon M.; Brinster, Ralph L.

    2014-01-01

    This review addresses current understanding of the germline stem cell niche unit in mammalian testes. Spermatogenesis is a classic model of tissue-specific stem cell function relying on self-renewal and differentiation of spermatogonial stem cells (SSCs). These fate decisions are influenced by a niche microenvironment composed of a growth factor milieu that is provided by several testis somatic support cell populations. Investigations over the last two decades have identified key determinants of the SSC niche including cytokines that regulate SSC functions and support cells providing these factors, adhesion molecules that influence SSC homing, and developmental heterogeneity of the niche during postnatal aging. Emerging evidence suggests that Sertoli cells are a key support cell population influencing the formation and function of niches by secreting soluble factors and possibly orchestrating contributions of other support cells. Investigations with mice have shown that niche influence on SSC proliferation differs during early postnatal development and adulthood. Moreover, there is mounting evidence of an age-related decline in niche function, which is likely influenced by systemic factors. Defining the attributes of stem cell niches is key to developing methods to utilize these cells for regenerative medicine. The SSC population and associated niche comprise a valuable model system for study that provides fundamental knowledge about the biology of tissue-specific stem cells and their capacity to sustain homeostasis of regenerating tissue lineages. While the stem cell is essential for maintenance of all self-renewing tissues and has received considerable attention, the role of niche cells is at least as important and may prove to be more receptive to modification in regenerative medicine. PMID:22535892

  11. Report on the Trilateral Initiative. IAEA verification of weapon-origin material in the Russian Federation and the United States

    International Nuclear Information System (INIS)

    Shea, Thomas E.

    2001-01-01

    Just over five years ago, the Trilateral Initiative was launched to investigate the technical, legal and financial issues associated with IAEA verification of weapon-origin fissile material in the Russian Federation and the United States. Since then, the Joint Working Group has developed concepts and equipment suitable for such a verification mission, anticipating that the States would submit classified forms of fissile material to IAEA verification under new agreements developed for this purpose. This article summarizes the accomplishments to date and identifies the future steps foreseen under the Trilateral Initiative. As there is no legal commitment on the Parties to this Initiative as yet, the issues considered are still changing. Since it was launched, the Initiative has been given a sense of importance and weight, raising the expectations of the international community. The Final Document of the 2000 Conference on the Treaty on the Non-Proliferation of Nuclear Weapons (NPT), for example, under the review of Article VI of the Treaty, includes the statement to 'complete and implement the Trilateral Initiative'. It was launched following independent statements by the President of the United States beginning in 1993, and by the President of the Russian Federation in 1996. It is an Initiative between the IAEA, the Russian Federation and the United States that is in the context of Article VI of the NPT. The intention is to examine the technical, legal and financial issues associated with IAEA verification of weapon origin and other fissile material released from defense programmes in those two countries

  12. Individual- and contextual-level factors associated with client-initiated HIV testing

    Directory of Open Access Journals (Sweden)

    Claudia Renata dos Santos Barros

    Full Text Available ABSTRACT: Background: Knowing the reasons for seeking HIV testing is central for HIV prevention. Despite the availability of free HIV counseling and testing in Brazil, coverage remains lacking. Methods: Survey of 4,760 respondents from urban areas was analyzed. Individual-level variables included sociodemographic characteristics; sexual and reproductive health; HIV/AIDS treatment knowledge and beliefs; being personally acquainted with a person with HIV/AIDS; and holding discriminatory ideas about people living with HIV. Contextual-level variables included the Human Development Index (HDI of the municipality; prevalence of HIV/AIDS; and availability of local HIV counseling and testing (CT services. The dependent variable was client-initiated testing. Multilevel Poisson regression models with random intercepts were used to assess associated factors. Results: Common individual-level variables among men and women included being personally acquainted with a person with HIV/AIDS and age; whereas discordant variables included those related to sexual and reproductive health and experiencing sexual violence. Among contextual-level factors, availability of CT services was variable associated with client-initiated testing among women only. The contextual-level variable “HDI of the municipality” was associated with client-initiated testing among women. Conclusion: Thus, marked gender differences in HIV testing were found, with a lack of HIV testing among married women and heterosexual men, groups that do not spontaneously seek testing.

  13. Technical progress report. Private sector initiatives between the United States and Japan. January 1992 - December 1992

    International Nuclear Information System (INIS)

    1993-01-01

    OAK A271 This annual report for calendar year 1992 describes the efforts performed under the Private Sector Initiatives contract. The report also describes those efforts that have continued with private funding after being initiated under this contract

  14. Technical progress report. Private sector initiatives between the United States and Japan. January 1990 - December 1990

    International Nuclear Information System (INIS)

    1993-01-01

    OAK A271 This annual report for calendar year 1990 describes the efforts performed under the Private Sector Initiatives contract. The report also describes those efforts that have continued with private funding after being initiated under this contract

  15. The Field Lysimeter Test Facility (FLTF) at the Hanford Site: Installation and initial tests

    International Nuclear Information System (INIS)

    Gee, G.W.; Kirkham, R.R.; Downs, J.L.; Campbell, M.D.

    1989-02-01

    The objectives of this program are to test barrier design concepts and to demonstrate a barrier design that meets established performance criteria for use in isolating wastes disposed of near-surface at the Hanford Site. Specifically, the program is designed to assess how well the barriers perform in controlling biointrusion, water infiltration, and erosion, as well as evaluating interactions between environmental variables and design factors of the barriers. To assess barrier performance and design with respect to infiltration control, field lysimeters and small- and large-scale field plots are planned to test the performance of specific barrier designs under actual and modified (enhanced precipitation) climatic conditions. The Field Lysimeter Test Facility (FLTF) is located in the 600 Area of the Hanford Site just east of the 200 West Area and adjacent to the Hanford Meteorological Station. The FLTF data will be used to assess the effectiveness of selected protective barrier configurations in controlling water infiltration. The facility consists of 14 drainage lysimeters (2 m dia x 3 m deep) and four precision weighing lysimeters (1.5 m x 1.5 m x 1.7 m deep). The lysimeters are buried at grade and aligned in a parallel configuration, with nine lysimeters on each side of an underground instrument chamber. The lysimeters were filled with materials to simulate a multilayer protective barrier system. Data gathered from the FLTF will be used to compare key barrier components and to calibrate and test models for predicting long-term barrier performance

  16. JTst - An Automated Unit Testing Tool for Java Program

    OpenAIRE

    Kamal Z.  Zamli; Nor A. M.  Isa

    2008-01-01

    Software testing is an integral part of software development lifecycle. Lack of testing can often lead to disastrous consequences including lost of data, fortunes, and even lives. Despite its importance, current software testing practice lacks automation, and is still primarily based on highly manual processes from the generation of test cases up to the actual execution of the test. Although the emergence of helpful automated testing tools in the market is blooming, their adoptions are lackin...

  17. 78 FR 38411 - Vogtle Electric Generating Plant, Unit 4; Inspections, Tests, Analyses, and Acceptance Criteria

    Science.gov (United States)

    2013-06-26

    ... Plant, Unit 4; Inspections, Tests, Analyses, and Acceptance Criteria AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria completion. SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) staff has determined that the inspections, tests...

  18. Canada-United States-Mexico Trilateral Cooperation on Childhood Obesity Initiative.

    Science.gov (United States)

    Rabadán-Diehl, Cristina; Safdie, Margarita; Rodin, Rachel

    2016-08-01

    Childhood obesity is an important public health problem that affects countries in the Americas. In 2014, Pan American Health Organization (PAHO) Member States agreed on a Plan of Action for the Prevention of Obesity in Children and Adolescents in an effort to address the impact of this disorder in the Americas region. The interventions laid out in this regional plan are multi-faceted and require multi-sectoral partnerships. Building on a strong history of successful trilateral collaboration, Canada, Mexico, and the United States formed a partnership to address the growing epidemic of childhood obesity in the North American region. This collaborative effort, known as the Trilateral Cooperation on Childhood Obesity Initiative, is the first initiative in the region to address chronic noncommunicable diseases by bringing together technical and policy experts, with strong leadership and support from the secretaries and ministers of health. The Initiative's goals include increasing levels of physical activity and reducing sedentary behavior through 1) increased social mobilization and citizen engagement, 2) community- based outreach, and 3) changes to the built (man-made) environment. This article describes the background and development process of the Initiative; specific goals, activities, and actions achieved to date; and opportunities and next steps. This information may be useful for those forming other partnerships designed to address childhood obesity or other complex public health challenges in the region. RESUMEN La obesidad infantil es un problema de salud pública importante que afecta a los países de las Américas. En el 2014, los Estados Miembros de la Organización Panamericana de la Salud (OPS) acordaron un Plan de acción para la prevención de la obesidad en la niñez y la adolescencia con el fin de hacer frente a las repercusiones de este trastorno en la Región de las Américas. Las intervenciones que componen este plan regional son multifacéticas y

  19. Reactivity Initiated Accident Test Series: Test RIA 1-2. Quick look report

    International Nuclear Information System (INIS)

    Martinson, Z.R.; Semken, R.S.; Smith, R.H.; Osetek, D.J.

    1978-12-01

    The primary objectives of Test RIA 1-2 were to (a) characterize the response of preirradiated fuel rods during an RIA event conducted at boiling water reactor (BWR) hot-startup conditions for an axial peak pellet surface energy of 200 cal/g UO 2 , and (b) evaluate the effect of internal rod pressure on preirradiated fuel rod response during an RIA event. The test consisted of four, individually shrouded, pressurized water reactor-type fuel rods previously irradiated to burnups of about 4800 MWd/t. In addition to the power calibration and preconditioning, the fuel rods were subjected to a single power burst that deposited a total pellet surface energy of approximately 200 cal/gm UO 2 at the axial peak power location (estimated using the core power chambers to relate steady state and transient powers). The test data indicate that the two irradiated fuel rods prepressurized to 2.41 MPa did not fail. FRAP-T4 calculations had predicted that prompt cladding rupture would occur for pellet surface energy depositions of 206 cal/g or greater. Although the two fuel rods prepressurized to 2.41 MPa did not fail, the data indicate that at least one of the two fuel rods prepressurized to 0.1 MPa did fail. Based on the core power chamber data, this rod failure indicates a threshold for the preirradiated fuel rods near or below 200 cal/g UO 2 total pellet surface energy at the axial flux peak

  20. Pilot scale test of a produced water-treatment system for initial removal of organic compounds

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, Enid J [Los Alamos National Laboratory; Kwon, Soondong [UT-AUSTIN; Katz, Lynn [UT-AUSTIN; Kinney, Kerry [UT-AUSTIN

    2008-01-01

    A pilot-scale test to remove polar and non-polar organics from produced water was performed at a disposal facility in Farmington NM. We used surfactant-modified zeolite (SMZ) adsorbent beds and a membrane bioreactor (MBR) in combination to reduce the organic carbon content of produced water prior to reverse osmosis (RO). Reduction of total influent organic carbon (TOC) to 5 mg/L or less is desirable for efficient RO system operation. Most water disposed at the facility is from coal-bed gas production, with oil production waters intermixed. Up to 20 gal/d of produced water was cycled through two SMZ adsorbent units to remove volatile organic compounds (BTEX, acetone) and semivolatile organic compounds (e.g., napthalene). Output water from the SMZ units was sent to the MBR for removal of the organic acid component of TOC. Removal of inorganic (Mn and Fe oxide) particulates by the SMZ system was observed. The SMZ columns removed up to 40% of the influent TOC (600 mg/L). BTEX concentrations were reduced from the initial input of 70 mg/L to 5 mg/L by the SMZ and to an average of 2 mg/L after the MBR. Removal rates of acetate (input 120-170 mg/L) and TOC (input up to 45 mg/L) were up to 100% and 92%, respectively. The water pH rose from 8.5 to 8.8 following organic acid removal in the MBR; this relatively high pH was likely responsible for observed scaling of the MBR internal membrane. Additional laboratory studies showed the scaling can be reduced by metered addition of acid to reduce the pH. Significantly, organic removal in the MBR was accomplished with a very low biomass concentration of 1 g/L throughout the field trial. An earlier engineering evaluation shows produced water treatment by the SMZ/MBR/RO system would cost from $0.13 to $0.20 per bbl at up to 40 gpm. Current estimated disposal costs for produced water are $1.75 to $4.91 per bbl when transportation costs are included, with even higher rates in some regions. Our results suggest that treatment by an SMZ

  1. A Nonlinear Unit Root Test in the Presence of an Unknown Break

    OpenAIRE

    Popp, Stephan

    2008-01-01

    The Perron test is the most commonly applied procedure to test for a unit root in the presence of a structural break of unknown timing in the trend function. Deriving the Perron-type test regression from an unobserved component model, it is shown that the test regression in fact is nonlinear in coefficient. Taking account of the nonlinearity leads to a test with properties that are exclusively assigned to Schmidt-Phillips LM-type unit root tests.

  2. Out-pile test plan for lifetime extension of shutoff units in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Joe, Y. G.; Lee, J. H.; Jeong, Y. H.; Woo, S. I.; Ryu, J. S.; Kim, Y. G.; Park, Y. C.; Kim, H. G.; Woo, J. S. [KAERI, Taejon (Korea, Republic of)

    2003-10-01

    It is estimated that the number of drops of shutoff rods in HANARO will reach the endurance verified numbers before the end of the reactor life. To resolve this situation, we have a plan to prepare of a new spare unit by the performance verification test for the local product, and extend the lifetime of shutoff units installed in the reactor by performing an additional endurance test in the out-pile test facility using an existing spare unit. This paper describes the overall situations and test plan for the out-pile test to extend the lifetime extension of shutoff unit.

  3. Metrology to enable high temperature erosion testing - A new european initiative

    DEFF Research Database (Denmark)

    Fry, A.T.; Gee, M.G.; Clausen, Sønnik

    2014-01-01

    is required. However, limitations in current measurement capability within this form of test prevent the advancement. A new European initiative, METROSION, on the development of high temperature solid particle erosion testing has a primary aim to develop this metrological framework. Several key parameters...... have been identified for measurement and control; these include temperature (of the sample, gas and particles), flow rate, size and shape of the erodent, angle of incidence of the particle stream and nozzle design. This paper outlines the aims and objectives of this new initiative. With a particular...

  4. Peripheral atherectomy practice patterns in the United States from the Vascular Quality Initiative.

    Science.gov (United States)

    Mohan, Sathish; Flahive, Julie M; Arous, Edward J; Judelson, Dejah R; Aiello, Francesco A; Schanzer, Andres; Simons, Jessica P

    2018-06-21

    Peripheral atherectomy has been shown to have technical success in single-arm studies, but clinical advantages over angioplasty and stenting have not been demonstrated, leaving its role unclear. We sought to describe patterns of atherectomy use in a real-world U.S. cohort to understand how it is currently being applied. The Vascular Quality Initiative was queried to identify all patients who underwent peripheral vascular intervention from January 2010 to September 2016. Descriptive statistics were performed to analyze demographics of the patients, comorbidities, indication, treatment modalities, and lesion characteristics. The intermittent claudication (IC) and critical limb ischemia (CLI) cohorts were analyzed separately. Of 85,605 limbs treated, treatment indication was IC in 51% (n = 43,506) and CLI in 49% (n = 42,099). Atherectomy was used in 15% (n = 13,092) of cases, equivalently for IC (15%; n = 6674) and CLI (15%; n = 6418). There was regional variation in use of atherectomy, ranging from a low of 0% in one region to a high of 32% in another region. During the study period, there was a significant increase in the proportion of cases that used atherectomy (11% in 2010 vs 18% in 2016; P < .0001). Compared with nonatherectomy cases, those with atherectomy use had higher incidence of prior peripheral vascular intervention (IC, 55% vs 43% [P < .0001]; CLI, 47% vs 41% [P < .0001]), greater mean number of arteries treated (IC, 1.8 vs 1.6 [P < .0001]; CLI, 2.1 vs 1.7 [P < .0001]), and lower proportion of prior leg bypass (IC, 10% vs 14% [P < .0001]; CLI, 11% vs 17% [P < .0001]). There was lower incidence of failure to cross the lesion (IC, 1% vs 4% [P < .0001]; CLI, 4% vs 7% [P < .0001]) but higher incidence of distal embolization (IC, 1.9% vs 0.8% [P < .0001]; CLI, 3.0% vs 1.4% [P < .0001]) and, in the CLI cohort, arterial perforation (1.4% vs 1.0%; P = .01). Despite a lack of evidence for atherectomy over angioplasty and stenting, its use has

  5. The Leapfrog initiative for intensive care unit physician staffing and its impact on intensive care unit performance: a narrative review.

    Science.gov (United States)

    Gasperino, James

    2011-10-01

    The field of critical care has changed markedly in recent years to accommodate a growing population of chronically critically ill patients. New administrative structures have evolved to include divisions, departments, and sections devoted exclusively to the practice of critical care medicine. On an individual level, the ability to manage complex multisystem critical illnesses and to introduce invasive monitoring devices defines the intensivist. On a systems level, critical care services managed by an intensivist-led multidisciplinary team are now recognized by their ability to efficiently utilize hospital resources and improve patient outcomes. Due to the numerous cost and quality issues related to the delivery of critical care medicine, intensive care unit physician staffing (IPS) has become a charged subject in recent years. Although the federal government has played a large role in regulating best practices by physicians, other third parties have entered the arena. Perhaps the most influential of these has been The Leapfrog Group, a consortium representing 130 employers and 65 Fortune 500 companies that purchase health care for their employees. This group has proposed specific regulatory guidelines for IPS that are purported to result in substantial cost containment and improved quality of care. This narrative review examines the impact of The Leapfrog Group's recommendations on critical care delivery in the United States. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. 14 CFR 33.96 - Engine tests in auxiliary power unit (APU) mode.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Engine tests in auxiliary power unit (APU... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.96 Engine tests in auxiliary power unit (APU) mode. If the engine is designed with a propeller brake which...

  7. Band of Brothers - Warrior Ethos, Unit Effectiveness and the Role of Initial Entry Training

    National Research Council Canada - National Science Library

    Sando, Donald

    2004-01-01

    .... Integral to continued professionalism of the Army is developing cultural attitudes beliefs and behaviors of a Warrior Ethos the culture of disciplined initiative teamwork determination sacrifice...

  8. General Atomic reprocessing pilot plant: description and results of initial testing

    International Nuclear Information System (INIS)

    1977-12-01

    In June 1976 General Atomic completed the construction of a reprocessing head-end cold pilot plant. In the year since then, each system within the head end has been used for experiments which have qualified the designs. This report describes the equipment in the plant and summarizes the results of the initial phase of reprocessing testing

  9. 77 FR 73056 - Initial Test Programs for Water-Cooled Nuclear Power Plants

    Science.gov (United States)

    2012-12-07

    ... Plants AGENCY: Nuclear Regulatory Commission. ACTION: Draft regulatory guide; request for comment... (DG), DG-1259, ``Initial Test Programs for Water-Cooled Nuclear Power Plants.'' This guide describes... (ITPs) for light water cooled nuclear power plants. DATES: Submit comments by January 31, 2013. Comments...

  10. Determination of the bonding strength in solid oxide fuel cells' interfaces by Schwickerath crack initiation test

    DEFF Research Database (Denmark)

    Boccaccini, D. N.; Sevecek, O.; Frandsen, Henrik Lund

    2017-01-01

    An adaptation of the Schwickerath crack initiation test (ISO 9693) was used to determine the bonding strength between an anode support and three different cathodes with a solid oxide fuel cell interconnect. Interfacial elemental characterization of the interfaces was carried out by SEM/EDS analys...

  11. Space and frequency-multiplexed optical linear algebra processor - Fabrication and initial tests

    Science.gov (United States)

    Casasent, D.; Jackson, J.

    1986-01-01

    A new optical linear algebra processor architecture is described. Space and frequency-multiplexing are used to accommodate bipolar and complex-valued data. A fabricated laboratory version of this processor is described, the electronic support system used is discussed, and initial test data obtained on it are presented.

  12. Brayton Power Conversion Unit Tested: Provides a Path to Future High-Power Electric Propulsion Missions

    Science.gov (United States)

    Mason, Lee S.

    2003-01-01

    Closed-Brayton-cycle conversion technology has been identified as an excellent candidate for nuclear electric propulsion (NEP) power conversion systems. Advantages include high efficiency, long life, and high power density for power levels from about 10 kWe to 1 MWe, and beyond. An additional benefit for Brayton is the potential for the alternator to deliver very high voltage as required by the electric thrusters, minimizing the mass and power losses associated with the power management and distribution (PMAD). To accelerate Brayton technology development for NEP, the NASA Glenn Research Center is developing a low-power NEP power systems testbed that utilizes an existing 2- kWe Brayton power conversion unit (PCU) from previous solar dynamic technology efforts. The PCU includes a turboalternator, a recuperator, and a gas cooler connected by gas ducts. The rotating assembly is supported by gas foil bearings and consists of a turbine, a compressor, a thrust rotor, and an alternator on a single shaft. The alternator produces alternating-current power that is rectified to 120-V direct-current power by the PMAD unit. The NEP power systems testbed will be utilized to conduct future investigations of operational control methods, high-voltage PMAD, electric thruster interactions, and advanced heat rejection techniques. The PCU was tested in Glenn s Vacuum Facility 6. The Brayton PCU was modified from its original solar dynamic configuration by the removal of the heat receiver and retrofitting of the electrical resistance gas heater to simulate the thermal input of a steady-state nuclear source. Then, the Brayton PCU was installed in the 3-m test port of Vacuum Facility 6, as shown. A series of tests were performed between June and August of 2002 that resulted in a total PCU operational time of about 24 hr. An initial test sequence on June 17 determined that the reconfigured unit was fully operational. Ensuing tests provided the operational data needed to characterize PCU

  13. Effects of zinc injection from hot functional test at Tomari Unit 3

    International Nuclear Information System (INIS)

    Hayakawa, Hitoshi; Mino, Yoshitaka; Nakahama, Satoshi; Aizawa, Yamato; Shimizu, Yuichi; Umehara, Ryuji; Kogawa, Noritaka

    2012-09-01

    At Tomari Nuclear Power Station unit 3 (hereafter Tomari unit 3, PWR, commercial operation from December 2009), the zinc injection for dose-rate reduction was started as early as at the Hot Functional Test (hereafter HFT) stage, for the first time in the world. The results of the Steam Generator (hereafter SG) insert plate analysis and the ambient dose-rate measurement till the end of the test operation reported heretofore, show the formation of the robust oxide film on the primary material surfaces and the associated corrosion suppression effect, and a considerable dose-rate reduction of about 40 to 60% lower than a reference plant. (*: Asian Water Chemistry Symposium in Nagoya on 2009 and NPC2010 in Canada). The material of SG tube is Alloy 690TT in Tomari unit 3. Generally, the dose-rates of the plants with Alloy 690TT SG are the highest at the 1. or 2. refueling outage (hereafter RFO), due to the effects of the Ni dissolution from the initial corrosion of Alloy 690TT. Therefore, the dose-rate of Tomari unit 3 at the 1. RFO is compared with those of the other Japanese PWR plants at their 1. RFO. As the result, the dose-rates inside the main components such as SG, Main Coolant Pipe (hereafter MCP) and Reactor Vessel (hereafter RV) are about 50% lower at the 1. RFO of Tomari unit 3 than those of a reference plant (a 3-Loop PWR plant in Japan). Therefore, an additional dose-rate reduction effects is expected by the Ni release rate reduction from Alloy 690TT and the effect of zinc injection. In this report, the actual dose-rates at the primary main components, the trends of the water chemistry and dose rates reduction effect with the zinc injection at the 1. RFO (offline in January 2011) of Tomari unit 3 are introduced. Also, a part of the experiences at the 2. RFO (offline in May 2012) is introduced. (authors)

  14. Importance Analysis of In-Service Testing Components for Ulchin Unit 3

    International Nuclear Information System (INIS)

    Dae-Il Kan; Kil-Yoo Kim; Jae-Joo Ha

    2002-01-01

    We performed an importance analysis of In-Service Testing (IST) components for Ulchin Unit 3 using the integrated evaluation method for categorizing component safety significance developed in this study. The importance analysis using the developed method is initiated by ranking the component importance using quantitative PSA information. The importance analysis of the IST components not modeled in the PSA is performed through the engineering judgment, based on the expertise of PSA, and the quantitative and qualitative information for the IST components. The PSA scope for importance analysis includes not only Level 1 and 2 internal PSA but also Level 1 external and shutdown/low power operation PSA. The importance analysis results of valves show that 167 (26.55%) of the 629 IST valves are HSSCs and 462 (73.45%) are LSSCs. Those of pumps also show that 28 (70%) of the 40 IST pumps are HSSCs and 12 (30%) are LSSCs. (authors)

  15. Assessment of Coping Capability of KORI Unit 1 under Extended Loss AC Power and Loss of Ultimate Heat Sink Initiated by Beyond Design Natural Disaster

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Hyun; Ha, Sang Jun [KHNP CRI, Daejeon (Korea, Republic of); Han, Kee Soo [Nuclear Engineering Service and Solution (NESS) Co. Ltd., Deajeon (Korea, Republic of); Park, Chan Eok [KEPCO Engineering and Constructd., Deajeon (Korea, Republic of)

    2016-10-15

    In Korea, the government and industry performed comprehensive safety inspection on all domestic nuclear power plants against beyond design basis external events and fifty action items have been issued. In addition to post- Fukushima action items, the stress tests for all domestic nuclear power plants are on the way to enhance the safety of domestic nuclear power plants through finding the vulnerabilities in intentional stress conditions initiated by beyond design natural disaster. This paper presents assessment results of coping capability of KORI Unit 1 under the simultaneous Extended Loss of AC Power (ELAP) and Loss of Ultimate Heat Sink (LUHS) which is a representative plant condition initiated by beyond design natural disaster. The assessment of the coping capability of KORI Unit 1 has been performed under simultaneous the extended loss of AC power and loss of ultimate heat sink initiated by beyond design natural disaster. It is concluded that KORI Unit 1 has the capability, in the event of loss of safety functions by beyond design natural disaster, to sufficiently cool down the reactor core without fuel damage, to keep pressure boundaries of the reactor coolant system in transient condition and to control containment and temperature to maintain the integrity of the containment buildings.

  16. Assessment of Coping Capability of KORI Unit 1 under Extended Loss AC Power and Loss of Ultimate Heat Sink Initiated by Beyond Design Natural Disaster

    International Nuclear Information System (INIS)

    Kim, Chang Hyun; Ha, Sang Jun; Han, Kee Soo; Park, Chan Eok

    2016-01-01

    In Korea, the government and industry performed comprehensive safety inspection on all domestic nuclear power plants against beyond design basis external events and fifty action items have been issued. In addition to post- Fukushima action items, the stress tests for all domestic nuclear power plants are on the way to enhance the safety of domestic nuclear power plants through finding the vulnerabilities in intentional stress conditions initiated by beyond design natural disaster. This paper presents assessment results of coping capability of KORI Unit 1 under the simultaneous Extended Loss of AC Power (ELAP) and Loss of Ultimate Heat Sink (LUHS) which is a representative plant condition initiated by beyond design natural disaster. The assessment of the coping capability of KORI Unit 1 has been performed under simultaneous the extended loss of AC power and loss of ultimate heat sink initiated by beyond design natural disaster. It is concluded that KORI Unit 1 has the capability, in the event of loss of safety functions by beyond design natural disaster, to sufficiently cool down the reactor core without fuel damage, to keep pressure boundaries of the reactor coolant system in transient condition and to control containment and temperature to maintain the integrity of the containment buildings

  17. Construction and Initial Tests of the Electrostatic Septa for MedAustron

    CERN Document Server

    Borburgh, J; Boucly, C; Kramer, T; Prost, A; Dorda, U; Stadlbauer, T

    2013-01-01

    For the MedAustron facility under construction in Wiener Neustadt/Austria, two electrostatic septa are built in collaboration with CERN. These septa will be used for the multi-turn injection of protons and ions, as well as for the slow extraction from the synchrotron. The power supplies are designed to combine the required precision with the capability to cycle sufficiently fast to keep up with the machine cycle. The septa are being assembled at CERN. Initial tests have been done on the remote displacement system to validate its precision and communication protocol with the MedAustron control system. Subsequently the septa are tested for vacuum performance and then HV conditioned. The construction of the septa, the requirements of the power supplies and the high voltage circuit will be described. Results of the initial laboratory tests, prior to installation in the accelerator, will be given.

  18. Initial Flight Test of the Production Support Flight Control Computers at NASA Dryden Flight Research Center

    Science.gov (United States)

    Carter, John; Stephenson, Mark

    1999-01-01

    The NASA Dryden Flight Research Center has completed the initial flight test of a modified set of F/A-18 flight control computers that gives the aircraft a research control law capability. The production support flight control computers (PSFCC) provide an increased capability for flight research in the control law, handling qualities, and flight systems areas. The PSFCC feature a research flight control processor that is "piggybacked" onto the baseline F/A-18 flight control system. This research processor allows for pilot selection of research control law operation in flight. To validate flight operation, a replication of a standard F/A-18 control law was programmed into the research processor and flight-tested over a limited envelope. This paper provides a brief description of the system, summarizes the initial flight test of the PSFCC, and describes future experiments for the PSFCC.

  19. Testing for seasonal unit roots in monthly panels of time series

    NARCIS (Netherlands)

    R.M. Kunst (Robert); Ph.H.B.F. Franses (Philip Hans)

    2009-01-01

    textabstractWe consider the problem of testing for seasonal unit roots in monthly panel data. To this aim, we generalize the quarterly CHEGY test to the monthly case. This parametric test is contrasted with a new nonparametric test, which is the panel counterpart to the univariate RURS test that

  20. Operational test procedure for SY tank farm replacement exhauster unit

    International Nuclear Information System (INIS)

    McClees, J.

    1995-01-01

    This operational test procedure will verify that the remaining functions not tested per WHC-SD-WM-ATP-080, or components disturbed during final installation, as well as interfaces with other tank farm equipment and remote monitoring stations are operating correctly

  1. Lumped Parameter Modeling for Rapid Vibration Response Prototyping and Test Correlation for Electronic Units

    Science.gov (United States)

    Van Dyke, Michael B.

    2013-01-01

    Present preliminary work using lumped parameter models to approximate dynamic response of electronic units to random vibration; Derive a general N-DOF model for application to electronic units; Illustrate parametric influence of model parameters; Implication of coupled dynamics for unit/board design; Demonstrate use of model to infer printed wiring board (PWB) dynamics from external chassis test measurement.

  2. 76 FR 82323 - Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units

    Science.gov (United States)

    2011-12-30

    ... Filtration and Adsorption Units AGENCY: Nuclear Regulatory Commission. ACTION: Draft regulatory guide... for Air Filtration and Adsorption Units of Postaccident Engineered-Safety-Feature Atmosphere Cleanup... testing of air filtration and iodine adsorption units of engineered-safety-feature (ESF) atmosphere...

  3. Anechoic Chamber test of the Electromagnetic Measurement System ground test unit

    Science.gov (United States)

    Stevenson, L. E.; Scott, L. D.; Oakes, E. T.

    1987-04-01

    The Electromagnetic Measurement System (EMMS) will acquire data on electromagnetic (EM) environments at key weapon locations on various aircraft certified for nuclear weapons. The high-frequency ground unit of the EMMS consists of an instrumented B61 bomb case that will measure (with current probes) the localized current density resulting from an applied EM field. For this portion of the EMMS, the first system test was performed in the Anechoic Chamber Facility at Sandia National Laboratories, Albuquerque, New Mexico. The EMMS pod was subjected to EM radiation at microwave frequencies of 1, 3, and 10 GHz. At each frequency, the EMMS pod was rotated at many positions relative to the microwave source so that the individual current probes were exposed to a direct line-of-sight illumination. The variations between the measured and calculated electric fields for the current probes with direct illumination by the EM source are within a few db. The results obtained from the anechoic test were better than expected and verify that the high frequency ground portion of the EMMS will accurately measure the EM environments for which it was designed.

  4. Rural-urban differences in breastfeeding initiation in the United States.

    Science.gov (United States)

    Sparks, P Johnelle

    2010-05-01

    Research has noted a rural disadvantage in breastfeeding initiation; however, most previous research has been based on nonrepresentative samples and has been limited in its ability to compare racial/ethnic differences in breastfeeding initiation based on residential location. This research fills this gap by examining a nationally representative sample of births using the Early Childhood Longitudinal Study-Birth Cohort (ECLS-B) to explore associations between rural-urban residence and maternal race/ethnicity on breastfeeding initiation. Results indicate that associations observed for rural-urban breastfeeding initiation differ based on maternal race/ethnicity and poverty status. These patterns likely reflect differences in economic resources, work environments, and social support among rural minority postpartum women.

  5. Incremental change or initial differences? Testing two models of marital deterioration.

    Science.gov (United States)

    Lavner, Justin A; Bradbury, Thomas N; Karney, Benjamin R

    2012-08-01

    Most couples begin marriage intent on maintaining a fulfilling relationship, but some newlyweds soon struggle, and others continue to experience high levels of satisfaction. Do these diverse outcomes result from an incremental process that unfolds over time, as prevailing models suggest, or are they a manifestation of initial differences that are largely evident at the start of the marriage? Using 8 waves of data collected over the first 4 years of marriage (N = 502 spouses, or 251 newlywed marriages), we tested these competing perspectives first by identifying 3 qualitatively distinct relationship satisfaction trajectory groups and then by determining the extent to which spouses in these groups were differentiated on the basis of (a) initial scores and (b) 4-year changes in a set of established predictor variables, including relationship problems, aggression, attributions, stress, and self-esteem. The majority of spouses exhibited high, stable satisfaction over the first 4 years of marriage, whereas declining satisfaction was isolated among couples with relatively low initial satisfaction. Across all predictor variables, initial values afforded stronger discrimination of outcome groups than did rates of change in these variables. Thus, readily measured initial differences are potent antecedents of relationship deterioration, and studies are now needed to clarify the specific ways in which initial indices of risk come to influence changes in spouses' judgments of relationship satisfaction. PsycINFO Database Record (c) 2012 APA, all rights reserved.

  6. 78 FR 53483 - Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3

    Science.gov (United States)

    2013-08-29

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 052-00025; NRC-2008-0252] Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3 AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria (ITAAC) completion...

  7. 78 FR 53484 - Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 4

    Science.gov (United States)

    2013-08-29

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 052-00026; NRC-2008-0252] Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 4 AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria (ITAAC) completion...

  8. 78 FR 65007 - Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3

    Science.gov (United States)

    2013-10-30

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 052-00026; NRC-2008-0252] Inspections, Tests, Analyses, and Acceptance Criteria; Vogtle Electric Generating Plant, Unit 3 AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria completion...

  9. A unit root test based on smooth transitions and nonlinear adjustment

    OpenAIRE

    Hepsag, Aycan

    2017-01-01

    In this paper, we develop a new unit root testing procedure which considers jointly for structural breaks and nonlinear adjustment. The structural breaks are modelled by means of a logistic smooth transition function and nonlinear adjustment is modelled by means of an ESTAR model. The empirical size of test is quite close to the nominal one and in terms of power; the new unit root test is generally superior to the alternative test. The new unit root test presents good size properties and does...

  10. The Power of Unit Root Tests Against Nonlinear Local Alternatives

    DEFF Research Database (Denmark)

    Demetrescu, Matei; Kruse, Robinson

    of Econometrics 112, 359-379) in comparison to the linear Dickey-Fuller test. To this end, we consider different adjustment schemes for deterministic terms. We provide asymptotic results which imply that the error variance has a severe impact on the behavior of the tests in the nonlinear case; the reason...... for such behavior is the interplay of nonstationarity and nonlinearity. In particular, we show that nonlinearity of the data generating process can be asymptotically negligible when the error variance is moderate or large (compared to the "amount of nonlinearity"), rendering the linear test more powerful than...

  11. Integrated Ground Operations Demonstration Units Testing Plans and Status

    Science.gov (United States)

    Johnson, Robert G.; Notardonato, William U.; Currin, Kelly M.; Orozco-Smith, Evelyn M.

    2012-01-01

    Cryogenic propellant loading operations with their associated flight and ground systems are some of the most complex, critical activities in launch operations. Consequently, these systems and operations account for a sizeable portion of the life cycle costs of any launch program. NASA operations for handling cryogens in ground support equipment have not changed substantially in 50 years, despite advances in cryogenics, system health management and command and control technologies. This project was developed to mature, integrate and demonstrate advancement in the current state of the art in these areas using two distinct integrated ground operations demonstration units (GODU): GODU Integrated Refrigeration and Storage (IRAS) and GODU Autonomous Control

  12. Initial Results from On-Orbit Testing of the Fram Memory Test Experiment on the Fastsat Micro-Satellite

    Science.gov (United States)

    MacLeond, Todd C.; Sims, W. Herb; Varnavas,Kosta A.; Ho, Fat D.

    2011-01-01

    The Memory Test Experiment is a space test of a ferroelectric memory device on a low Earth orbit satellite that launched in November 2010. The memory device being tested is a commercial Ramtron Inc. 512K memory device. The circuit was designed into the satellite avionics and is not used to control the satellite. The test consists of writing and reading data with the ferroelectric based memory device. Any errors are detected and are stored on board the satellite. The data is sent to the ground through telemetry once a day. Analysis of the data can determine the kind of error that was found and will lead to a better understanding of the effects of space radiation on memory systems. The test is one of the first flight demonstrations of ferroelectric memory in a near polar orbit which allows testing in a varied radiation environment. The initial data from the test is presented. This paper details the goals and purpose of this experiment as well as the development process. The process for analyzing the data to gain the maximum understanding of the performance of the ferroelectric memory device is detailed.

  13. Leak testing United States Nuclear Regulatory Commission type b packaging

    International Nuclear Information System (INIS)

    Lacy, K.A.

    1995-01-01

    The Waste Isolation Pilot Plant (WTPP) is a one of its kind research and development facility operated by the Department of Energy, Carlsbad Area Office. Located in southeastern New Mexico, the WTPP is designed to demonstrate the safe, permanent disposal of transuranic (TRU) radioactive nuclear waste, accumulated from 40 years of nuclear weapons production. Before the waste can be disposed of, it must first be safely transported from generator storage sites to the WIPP. To accomplish this, the TRUPACT-II was designed and fabricated. This double containment, non-vented waste packaging successfully completed a rigorous testing program, and in 1989 received a Certificate of Compliance (C of C) from the Nuclear Regulatory Commission (NRC). Currently, the TRUPACT-II is in use at Idaho National Engineering Laboratory to transport waste on site for characterization. The DOE/CAO is responsible for maintaining the TRUPACT-II C of C. The C of C requires performance of nondestructive examination (NDE), e.g., visual testing (VT), dimensional inspections, Liquid Dye Penetrant testing (PT), and Helium Leak Detection (HLD). The Waste Isolation Division (WID) uses HLD for verification of the containment integrity. The following HLD tests are performed on annual basis or when required, i.e. repairs or component replacement: (1) fabrication verification leak tests on both the outer containment vessel (OCV) and the inner containment vessel (ICV); (2) assembly verification leak tests on the OCV and ICV upper main o-rings; and (3) assembly verification leak tests on the OCV and the ICV vent port plugs. These tests are addressed in detail as part of this presentation

  14. Acceptance test for 900 MWe PWR unit replacement steam generators

    International Nuclear Information System (INIS)

    Gourguechon, B.

    1993-01-01

    During the first half of 1994, the Gravelines 1 steam generators will be replaced (SG replacement procedure). The new SG's differ from the former components notably by the alloy used for the tube bundle, in this case, the high chromium content Inconel 690. So, from this standpoint, they are to be considered as PWR 900 replacement SG first models and their thermal efficiency has consequently to be assessed. This will provide an opportunity of ensuring that the performance of the components delivered is in compliance with requirements and of making the necessary provisions if significant deviations are observed. The EFMT branch, which has been in charge of the instrumentation and acceptance of the different SG first models since the first PWR plants were commissioned, will be responsible for the acceptance tests and the ultimate validation of a performance assessment procedure applicable to the future replacement steam generators. The methods and tests proposed for SG expert appraisal are based on consideration of the importance of primary measurement quality for satisfactory SG assessment and of the new test facilities with which the 900 and 1 300 PWR plants are gradually being equipped. These facilities provide an on-site computer environment for tests compatible with the tools (PATTERN, etc.) used at EFMT and in other departments. This test is the first of this kind performed by EFMT and the test facility of a nuclear power plant. (author). 6 figs

  15. Crack initiation and propagation on the polymeric material ABS (Acrylonitrile Butadiene Styrene, under ultrasonic fatigue testing

    Directory of Open Access Journals (Sweden)

    G. M. Domínguez Almaraz

    2015-10-01

    Full Text Available Crack initiation and propagation have been investigated on the polymeric material ABS (Acrylonitrile Butadiene Styrene, under ultrasonic fatigue testing. Three controlled actions were implemented in order to carry out fatigue tests at very high frequency on this material of low thermal conductivity, they are: a The applying load was low to limit heat dissipation at the specimen neck section, b The dimensions of testing specimen were small (but fitting the resonance condition, in order to restraint the temperature gradient at the specimen narrow section, c Temperature at the specimen neck section was restrained by immersion in water or oil during ultrasonic fatigue testing. Experimental results are discussed on the basis of thermo-mechanical behaviour: the tail phenomenon at the initial stage of fatigue, initial shear yielding deformation, crazed development on the later stage, plastic strain on the fracture surface and the transition from low to high crack growth rate. In addition, a numerical analysis is developed to evaluate the J integral of energy dissipation and the stress intensity factor K, with the crack length

  16. On the asymptotic distribution of a unit root test against ESTAR alternatives

    NARCIS (Netherlands)

    Hanck, Christoph

    We derive the null distribution of the nonlinear unit root test proposed in Kapetanios et al. [Kapetanios, G., Shin, Y., Snell, A., 2003. Testing for a unit root in the nonlinear STAR framework, journal of Econometrics 112, 359-379] when nonzero means or both means and deterministic trends are

  17. 77 FR 30501 - Uncovered Innerspring Units From the People's Republic of China: Initiation of Anticircumvention...

    Science.gov (United States)

    2012-05-23

    ... Steel & Wire Spring Co., Ltd., and 164.75 percent on seven companies that qualified for separate rates... Malaysia'' and that ``{t{time} hese Chinese raw materials are further processed in Malaysia and combined with other materials into finished innerspring units and mattresses, for sale within Malaysia and for...

  18. Study of accelerated unit unloading mode initiated by turbine feed pump trip with TVSA fuel assemblies operation in WWER-1000

    International Nuclear Information System (INIS)

    Borysenko, V.I.; Kadenko, I.N.; Samoilenko, D.V.

    2012-01-01

    This paper provides the study results of accelerated unit unloading mode (AUU) initiated at WWER-1000 unit operated at 100 % power and its expediency in the event of single Turbo Feed Pump (TFP) failure. Modeling was performed using an advanced calculation code RELAP/SCDAPSIM/Mod3.4 and relevant model for KhNPP Unit No. 2. As the study shows, SCRAM cannot be prevented in case of failure of 3 main circulation pumps due to steam generators (SG) level drop. Based on the results obtained, it is reasonably justified to allow SCRAM signal instead of AUU activation in case of single TFP failure at power level more than 90 % of N n om. This will provide more sparing temperature modes for fuel assemblies and equipment, as well as prevent additional thermal cycling loads and violation of safe operation limits as SG water levels

  19. Electronic cigarette use and conventional cigarette smoking initiation among youth, United States, 2015-2016

    OpenAIRE

    Satomi Odani; Kristy Marynak; Brian Armour; Israel Agaku

    2018-01-01

    Background Electronic cigarettes (e-cigarettes) are the most commonly used tobacco product among U.S youth. We used cross-sectional, nationally representative data of U.S. middle and high school students to examine the association between e-cigarette use and cigarette smoking initiation. Methods Data were from the 2015 and 2016 National Youth Tobacco Surveys, a school-based survey of U.S. 6 th -12 th graders (pooled N=38,386). Questions on current age and age at initiation of dif...

  20. Acceptance test procedure for SY Tank Farm replacement exhauster unit

    Energy Technology Data Exchange (ETDEWEB)

    Becken, G.W.

    1994-12-16

    The proper functioning of a new 241-SY Tank Farm replacement exhauster will be acceptance tested, to establish operability and to provide an operational baseline for the equipment. During this test, a verification of all of the alarm and control circuits associated with the exhaust, which provide operating controls and/or signals to local and remote alarm/annunciator panels, shall be performed. Test signals for sensors that provide alarms, warnings, and/or interlocks will be applied to verify that alarm, warning, and interlock setpoints are correct. Alarm and warning lights, controls, and local and remote readouts for the exhauster will be verified to be adequate for proper operation of the exhauster. Testing per this procedure shall be conducted in two phases. The first phase of testing, to verify alarm, warning, and interlock setpoints primarily, will be performed in the MO-566 Fab Shop. The second phase of testing, to verify proper operation and acceptable interface with other tank farm systems, will be conducted after the exhauster and all associated support and monitoring equipment have been installed in the SY Tank Farm. The exhauster, which is mounted on a skid and which will eventually be located in the SY tank farm, receives input signals from a variety of sensors mounted on the skid and associated equipment. These sensors provide information such as: exhauster system inlet vacuum pressure; prefilter and HEPA filter differential pressures; exhaust stack sampler status; exhaust fan status; system status (running/shut down); and radiation monitoring systems status. The output of these sensors is transmitted to the exhauster annunciator panel where the signals are displayed and monitored for out-of-specification conditions.

  1. Exploring the initial steps of the testing process: frequency and nature of pre-preanalytic errors.

    Science.gov (United States)

    Carraro, Paolo; Zago, Tatiana; Plebani, Mario

    2012-03-01

    Few data are available on the nature of errors in the so-called pre-preanalytic phase, the initial steps of the testing process. We therefore sought to evaluate pre-preanalytic errors using a study design that enabled us to observe the initial procedures performed in the ward, from the physician's test request to the delivery of specimens in the clinical laboratory. After a 1-week direct observational phase designed to identify the operating procedures followed in 3 clinical wards, we recorded all nonconformities and errors occurring over a 6-month period. Overall, the study considered 8547 test requests, for which 15 917 blood sample tubes were collected and 52 982 tests undertaken. No significant differences in error rates were found between the observational phase and the overall study period, but underfilling of coagulation tubes was found to occur more frequently in the direct observational phase (P = 0.043). In the overall study period, the frequency of errors was found to be particularly high regarding order transmission [29 916 parts per million (ppm)] and hemolysed samples (2537 ppm). The frequency of patient misidentification was 352 ppm, and the most frequent nonconformities were test requests recorded in the diary without the patient's name and failure to check the patient's identity at the time of blood draw. The data collected in our study confirm the relative frequency of pre-preanalytic errors and underline the need to consensually prepare and adopt effective standard operating procedures in the initial steps of laboratory testing and to monitor compliance with these procedures over time.

  2. Centrifuge model tests of rainfall-induced slope failures for the investigation of the initiation conditions

    Science.gov (United States)

    Matziaris, Vasileios; Marshall, Alec; Yu, Hai-Sui

    2015-04-01

    Rainfall-induced landslides are very common natural disasters which cause damage to properties and infrastructure and may result in the loss of human lives. These phenomena often take place in unsaturated soil slopes and are triggered by the saturation of the soil profile, due to rain infiltration, which leads to a loss of shear strength. The aim of this study is to determine rainfall thresholds for the initiation of landslides under different initial conditions. Model tests of rainfall-induced landslides are conducted in the Nottingham Centre for Geomechanics 50g-T geotechnical centrifuge. Initially unsaturated plane-strain slope models made with fine silica sand are prepared at varying densities at 1g and accommodated within a climatic chamber which provides controlled environmental conditions. During the centrifuge flight at 60g, rainfall events of varying intensity and duration are applied to the slope models causing the initiation of slope failure. The impact of soil state properties and rainfall characteristics on the landslide initiation process are discussed. The variation of pore water pressures within the slope before, during and after simulated rainfall events is recorded using miniature pore pressure transducers buried in the soil model. Slope deformation is determined by using a high-speed camera and digital image analysis techniques.

  3. An external control unit implemented for stimulator ASIC testing ...

    African Journals Online (AJOL)

    ) for a stimulator ASIC testing purposes. The ECU consists of a graphical user interface (GUI) from the PC, a data transceiver and a power transmitter. The GUI was developed using MATLAB for stimulation data setup. The data transceiver was ...

  4. Measurements for testing of fluoroscopic screens, including the photofluorographic units

    International Nuclear Information System (INIS)

    Balfanz, R.

    1986-01-01

    Image quality control measurements for fluoroscopic screens and photofluorographs have shown that both types of equipment have a long operating life, so that constancy and technical performance tests are absolutely necessary. It is recommended to conclude in-service maintenance contracts with the manufacturers. (DG) [de

  5. RQ-21A Blackjack Small Tactical Unmanned Aircraft System (STUAS): Initial Operational Test and Evaluation Report

    Science.gov (United States)

    2015-06-29

    Evaluation Report June 2015 This report on the RQ-21A Blackjack Small Tactical Unmanned Aircraft System fulfills the provisions of Title 10...suitability of the RQ-21A Blackjack Small Tactical Unmanned Aircraft System (STUAS) during Initial Operational Test and Evaluation (IOT&E). The Navy’s...66.9 percent). The average service life of the propulsion modules was 48.9 hours, which does not meet the manufacturer’s stated 100-hour

  6. Precision closed bomb calorimeter for testing flame and gas producing initiators

    Science.gov (United States)

    Carpenter, D. R., Jr.; Taylor, A. C., Jr.

    1972-01-01

    A calorimeter has been developed under this study to help meet the needs of accurate performance monitoring of electrically or mechanically actuated flame and gas producing devices, such as squib-type initiators. A ten cubic centimeter closed bomb (closed volume) calorimeter was designed to provide a standard pressure trace and to measure a nominal 50 calorie output, using the basic components of a Parr Model 1411 calorimeter. Two prototype bombs were fabricated, pressure tested to 2600 psi, and extensively evaluated.

  7. Patterns of opioid initiation at first visits for pain in United States primary care settings.

    Science.gov (United States)

    Mundkur, Mallika L; Rough, Kathryn; Huybrechts, Krista F; Levin, Raisa; Gagne, Joshua J; Desai, Rishi J; Patorno, Elisabetta; Choudhry, Niteesh K; Bateman, Brian T

    2018-05-01

    The primary objective of this study was to characterize variation in patterns of opioid prescribing within primary care settings at first visits for pain, and to describe variation by condition, geography, and patient characteristics. 2014 healthcare utilization data from Optum's Clinformatics™ DataMart were used to evaluate individuals 18 years or older with an initial presentation to primary care for 1 of 10 common pain conditions. The main outcomes assessed were (1) the proportion of first visits for pain associated with an opioid prescription fill and (2) the proportion of opioid prescriptions with >7 days' supply. We identified 205 560 individuals who met inclusion criteria; 9.1% of all visits were associated with an opioid fill, ranging from 4.1% (headache) to 28.2% (dental pain). Approximately half (46%) of all opioid prescriptions supplied more than 7 days, and 10% of prescriptions supplied ≥30 days. We observed a 4-fold variation in rates of opioid initiation by state, with highest rates of prescribing in Alabama (16.6%) and lowest rates in New York (3.7%). In 2014, nearly half of all patients filling opioid prescriptions received more than 7 days' of opioids in an initial prescription. Policies limiting initial supplies have the potential to substantially impact opioid prescribing in the primary care setting. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Closure plan for the Test Area North-726 chromate water storage and Test Area North-726A chromate treatment units

    International Nuclear Information System (INIS)

    Smith, P.J.; Van Brunt, K.M.

    1992-11-01

    This document describes the proposed plan for closure of the Test Area North-726 chromate water storage and Test Area North-726A chromate treatment units at the Idaho National Engineering Laboratory in accordance with the Resource Conservation and Recovery Act interim status closure requirements. The location, size, capacity, and history of the units are described, and their current status is discussed. The units will be closed by treating remaining waste in storage, followed by thorough decontamination of the systems. Sufficient sampling and analysis, and documentation of all activities will be performed to demonstrate clean closure

  9. Out-of-pile test of zirconium cladding simulating reactivity initiated accident

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. H.; Lee, M. H.; Choi, B. K.; Bang, J. K.; Jung, Y. H. [KAERI, Taejon (Korea, Republic of)

    2004-07-01

    Mechanical properties of zirconium cladding such as Zircaloy-4 and advanced cladding were evaluated by ring tension test to simulate Reactivity-Initiated Accident (RIA) as an out-pile test. Cladding was hydrided by means of charging hydrogen up to 1000ppm to simulate high-burnup situation, finally fabricated to circumferential tensile specimen. Ring tension test was carried out from 0.01 to 1/sec to keep pace with actual RIA event. The results showed that mechanical strength of zirconium cladding increased at the value of 7.8% but ductility decreased at the 34% as applied strain rate and absorbed hydrogen increased. Further activities regarding out-of-pile testing plans for simulated high-burnup cladding were discussed in this paper.

  10. Measuring the initial earth pressure of granite using hydraulic fracturing test; Goseong and Yuseong areas

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byoung Yoon; Bae, Dae Seok; Kim, Chun Soo; Kim, Kyung Su; Koh, Young Kwon; Won, Kyung Sik [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-02-01

    This report provides the initial earth pressure of granitic rocks obtained from Deep Core Drilling Program which is carried out as part of the assessment of deep geological environmental condition. These data are obtained by hydraulic fracturing test in three boreholes drilled up to 350{approx}500 m depth at the Yuseong and Goseong sites. These sites were selected based on the result of preliminary site evaluation study. The boreholes are NX-size (76 mm) and vertical. The procedure of hydraulic fracturing test is as follows: - Selecting the testing positions by preliminary investigation using BHTV logging. - Performing the hydraulic fracturing test at each selected position with depth.- Estimating the shut-in pressure by the bilinear pressure-decay-rate method. - Estimating the fracture reopening pressure from the pressure-time curves.- Estimating the horizontal principal stresses and the direction of principal stresses. 65 refs., 39 figs., 12 tabs. (Author)

  11. An outlier robust unit root test with an application to the extended Nelson-Plosser data

    NARCIS (Netherlands)

    Lucas, André

    1995-01-01

    This paper considers unit root tests based on robust estimators with a high breakdown point and high efficiency. The asymptotic distribution of these tests is derived. Critical values for the test are obtained via simulation. It is found that the size of the classical OLS based Dickey-Fuller test

  12. Correlates of Human Papillomavirus (HPV) vaccination initiation and completion among 18-26 year olds in the United States.

    Science.gov (United States)

    Adjei Boakye, Eric; Lew, Daphne; Muthukrishnan, Meera; Tobo, Betelihem B; Rohde, Rebecca L; Varvares, Mark A; Osazuwa-Peters, Nosayaba

    2018-04-30

    To examine correlates of HPV vaccination uptake in a nationally representative sample of 18-26-year-old adults. Young adults aged 18-26 years were identified from the 2014 and 2015 National Health Interview Survey (n = 7588). Survey-weighted multivariable logistic regression models estimated sociodemographic factors associated with HPV vaccine initiation (≥1 dose) and completion (≥3 doses). Approximately 27% of study participants had initiated the HPV vaccine and 16% had completed the HPV vaccine. Participants were less likely to initiate the vaccine if they were men [(adjusted odds ratio) 0.19; (95% confidence interval) 0.16-0.23], had a high school diploma (0.40; 0.31-0.52) or less (0.46; 0.32-0.64) vs. college graduates, and were born outside the United States (0.52; 0.40-0.69). But, participants were more likely to initiate the HPV if they visited the doctor's office 1-5 times (2.09; 1.56-2.81), or ≥ 6 times (1.86; 1.48-2.34) within the last 12 months vs. no visits. Odds of completing HPV vaccine uptake followed the same pattern as initiation. And after stratifying the study population by gender and foreign-born status, these variables remained statistically significant. In our nationally representative study, only one out of six 18-26 year olds completed the required vaccine doses. Men, individuals with high school or less education, and those born outside the United States were less likely to initiate and complete the HPV vaccination. Our findings suggest that it may be useful to develop targeted interventions to promote HPV vaccination among those in the catch-up age range.

  13. Liquid Transfer Cryogenic Test Facility: Initial hydrogen and nitrogen no-vent fill data

    Science.gov (United States)

    Moran, Matthew E.; Nyland, Ted W.; Papell, S. Stephen

    1990-01-01

    The Liquid Transfer Cryogenic Test Facility is a versatile testbed for ground-based cryogenic fluid storage, handling, and transfer experimentation. The test rig contains two well instrumented tanks, and a third interchangeable tank, designed to accommodate liquid nitrogen or liquid hydrogen testing. The internal tank volumes are approx. 18, 5, and 1.2 cu. ft. Tank pressures can be varied from 2 to 30 psia. Preliminary no vent fill tests with nitrogen and hydrogen were successfully completed with the test rig. Initial results indicate that no vent fills of nitrogen above 90 percent full are achievable using this test configuration, in a 1-g environment, and with inlet liquid temperatures as high as 143 R, and an average tank wall temperature of nearly 300 R. This inlet temperature corresponds to a saturation pressure of 19 psia for nitrogen. Hydrogen proved considerably more difficult to transfer between tanks without venting. The highest temperature conditions resulting in a fill level greater than 90 percent were with an inlet liquid temperature of 34 R, and an estimated tank wall temperature of slightly more than 100 R. Saturation pressure for hydrogen at this inlet temperature is 10 psia. All preliminary no vent fill tests were performed with a top mounted full cone nozzle for liquid injection. The nozzle produces a 120 degree conical droplet spray at a differential pressure of 10 psi. Pressure in the receiving tank was held to less than 30 psia for all tests.

  14. Estimating Renewable Energy Economic Potential in the United States: Methodology and Initial Results

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Austin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Beiter, Philipp [National Renewable Energy Lab. (NREL), Golden, CO (United States); Heimiller, Donna [National Renewable Energy Lab. (NREL), Golden, CO (United States); Davidson, Carolyn [National Renewable Energy Lab. (NREL), Golden, CO (United States); Denholm, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States); Melius, Jennifer [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lopez, Anthony [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hettinger, Dylan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Mulcahy, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Porro, Gian [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-01

    The report describes a geospatial analysis method to estimate the economic potential of several renewable resources available for electricity generation in the United States. Economic potential, one measure of renewable generation potential, is defined in this report as the subset of the available resource technical potential where the cost required to generate the electricity (which determines the minimum revenue requirements for development of the resource) is below the revenue available in terms of displaced energy and displaced capacity.

  15. Results of testing the frontal AK-3 extraction unit

    Energy Technology Data Exchange (ETDEWEB)

    Yakovlev, N I; Dolinskii, A M; Kolesnikov, M A

    1978-10-01

    From August to November 1970, on site testing of a protype frontal AK excavating rig developed by Giprouglemesh for use on gentle sloping seams was conducted in the Novaya mine of the Kuzbass Ugol Consolidated. The AK-3 consists of a cutting assembly in the form of a ring frontal slicer with two drives, hydraulic operated sectionalized support timbers of the enclosed lift type, conjugated timbering with ventilation and conveyor shafts, personnel elevator and hydraulic and electrical ancillary equipment. The production capacity of the rig in longwalls is 2.2 times greater on the average than by using drillhole blasting methods. Tests demonstrated that the main advantage of the Ak-3 was the single operation, continuous flow mode of coal extraction and remote frontal movement of timber sections, which ensured high capacity loading at the face and the capability of automating all procedures and eliminating all workers from the extraction face.

  16. Corrective Action Plan for Corrective Action Unit 261: Area 25 Test Cell A Leachfield System, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    T. M. Fitzmaurice

    2000-08-01

    This Corrective Action Plan (CAP) has been prepared for the Corrective Action Unit (CAU)261 Area 25 Test Cell A Leachfield System in accordance with the Federal Facility and Consent Order (Nevada Division of Environmental Protection [NDEP] et al., 1996). This CAP provides the methodology for implementing the approved corrective action alternative as listed in the Corrective Action Decision Document (U.S. Department of Energy, Nevada Operations Office, 1999). Investigation of CAU 261 was conducted from February through May of 1999. There were no Constituents of Concern (COCs) identified at Corrective Action Site (CAS) 25-05-07 Acid Waste Leach Pit (AWLP). COCs identified at CAS 25-05-01 included diesel-range organics and radionuclides. The following closure actions will be implemented under this plan: Because COCs were not found at CAS 25-05-07 AWLP, no action is required; Removal of septage from the septic tank (CAS 25-05-01), the distribution box and the septic tank will be filled with grout; Removal of impacted soils identified near the initial outfall area; and Upon completion of this closure activity and approval of the Closure Report by NDEP, administrative controls, use restrictions, and site postings will be used to prevent intrusive activities at the site.

  17. Corrective Action Plan for Corrective Action Unit 261: Area 25 Test Cell A Leachfield System, Nevada Test Site, Nevada; TOPICAL

    International Nuclear Information System (INIS)

    T. M. Fitzmaurice

    2000-01-01

    This Corrective Action Plan (CAP) has been prepared for the Corrective Action Unit (CAU)261 Area 25 Test Cell A Leachfield System in accordance with the Federal Facility and Consent Order (Nevada Division of Environmental Protection[NDEP] et al., 1996). This CAP provides the methodology for implementing the approved corrective action alternative as listed in the Corrective Action Decision Document (U.S. Department of Energy, Nevada Operations Office, 1999). Investigation of CAU 261 was conducted from February through May of 1999. There were no Constituents of Concern (COCs) identified at Corrective Action Site (CAS) 25-05-07 Acid Waste Leach Pit (AWLP). COCs identified at CAS 25-05-01 included diesel-range organics and radionuclides. The following closure actions will be implemented under this plan: Because COCs were not found at CAS 25-05-07 AWLP, no action is required; Removal of septage from the septic tank (CAS 25-05-01), the distribution box and the septic tank will be filled with grout; Removal of impacted soils identified near the initial outfall area; and Upon completion of this closure activity and approval of the Closure Report by NDEP, administrative controls, use restrictions, and site postings will be used to prevent intrusive activities at the site

  18. Universal Physical Fitness Testing for United States Guardians Afloat

    Science.gov (United States)

    2016-06-10

    fitness tests assist with establishing a high retention rate and reducing absenteeism .”58 Robert Behn talks about measurements as an “overall...https://www.policeone.com/police- products /fitness-health-wellness/articles/ 1641504-Final-Word-Mandatory-Fitness-Standards-for-In-Service-Officers...30, 2016, http://static.e-publishing.af.mil/ production /1/af_a1/ publication/afi36-2905/afi36-2905.pdf. 95 Major Richard T. Gindhard Jr., “The Air

  19. Modal Testing of the NPSAT1 Engineering Development Unit

    Science.gov (United States)

    2012-07-01

    erkläre ich, dass die vorliegende Master Arbeit von mir selbstständig und nur unter Verwendung der angegebenen Quellen und Hilfsmittel angefertigt...logarithmic scale . As 5 Figure 2 shows, natural frequencies are indicated by large values of the first CMIF (peaks), and multiple modes can be detected by...structure’s behavior. Ewins even states, “that no large- scale modal test should be permitted to proceed until some preliminary SDOF analyses have

  20. Electronic cigarette use and conventional cigarette smoking initiation among youth, United States, 2015-2016

    Directory of Open Access Journals (Sweden)

    Satomi Odani

    2018-03-01

    Full Text Available Background Electronic cigarettes (e-cigarettes are the most commonly used tobacco product among U.S youth. We used cross-sectional, nationally representative data of U.S. middle and high school students to examine the association between e-cigarette use and cigarette smoking initiation. Methods Data were from the 2015 and 2016 National Youth Tobacco Surveys, a school-based survey of U.S. 6 th -12 th graders (pooled N=38,386. Questions on current age and age at initiation of different tobacco products were used to assess temporality. The study included 35,775 students who had never smoked conventional cigarettes five years before the survey (i.e., baseline, including never-smokers and those who first smoked < 5 years ago. Baseline never smokers were classified by e-cigarette use status into: (1 those who ever used e-cigarettes on/before or without ever smoking cigarettes; or (2 those who had never used e-cigarettes, or started only after initiating cigarette smoking. The outcome variables were cigarette smoking at pre-determined periods: any time within the past 5 years; past 1 year; past 6 months; past 30 days; and past 7 days. Adjusted odds ratios (AOR were calculated using multivariable logistic regression. The models controlled for socio-demographic characteristics and use of smokeless tobacco, cigars, and hookah on/before cigarette smoking initiation. Results Among baseline never cigarette smokers, 17.4% used e-cigarettes, and 16.7% initiated cigarette smoking within the past 5 years. Those who used e-cigarettes on/before ever smoking cigarettes had higher odds of smoking cigarettes than those who did not at all periods assessed: any time within the past 5 years (AOR=2.61; past 1 year (AOR=3.18, past 6 months (AOR=2.59, past 30 days (AOR=1.75, and past 7 days (AOR=1.38 (all p< 0.05. Conclusions These cross-sectional findings reveal that e-cigarette use was associated with conventional cigarette smoking initiation among U.S. youth

  1. Thermal desorption treatability test conducted with VAC*TRAX Unit

    International Nuclear Information System (INIS)

    1996-01-01

    In 1992, Congress passed the Federal Facilities Compliance Act, requiring the U.S. Department of Energy (DOE) to treat and dispose of its mixed waste in accordance with Resource Conservation and Recovery Act (RCRA) treatment standards. In response to the need for mixed-waste treatment capacity, where off-site commercial treatment facilities do not exist or cannot be used, the DOE Albuquerque Operations Office (DOE-AL) organized a Treatment Selection Team to match mixed waste with treatment options and develop a strategy for treatment of mixed waste. DOE-AL manages nine sites with mixed-waste inventories. The Treatment Selection Team determined a need to develop mobile treatment units (MTUs) to treat waste at the sites where the wastes are generated. Treatment processes used for mixed wastes must remove the hazardous component (i.e., meet RCRA treatment standards) and contain the radioactive component in a form that will protect the worker, public, and environment. On the basis of the recommendations of the Treatment Selection Team, DOE-AL assigned projects to the sites to bring mixed-waste treatment capacity on-line. The three technologies assigned to the DOE Grand Junction Projects Office (DOE-GJPO) include thermal desorption (TD), evaporative oxidation, and waste water evaporation

  2. Increases in Recent HIV Testing Among Men Who Have Sex With Men Coincide With the Centers for Disease Control and Prevention's Expanded Testing Initiative

    Science.gov (United States)

    Cooley, Laura A.; Wejnert, Cyprian; Rose, Charles E.; Paz-Bailey, Gabriela; Taussig, Jennifer; Gern, Robert; Hoyte, Tamika; Salazar, Laura; White, Jianglan; Todd, Jeff; Bautista, Greg; Flynn, Colin; Sifakis, Frangiscos; German, Danielle; Isenberg, Debbie; Driscoll, Maura; Hurwitz, Elizabeth; Doherty, Rose; Wittke, Chris; Prachand, Nikhil; Benbow, Nanette; Melville, Sharon; Pannala, Praveen; Yeager, Richard; Sayegh, Aaron; Dyer, Jim; Sheu, Shane; Novoa, Alicia; Thrun, Mark; Al-Tayyib, Alia; Wilmoth, Ralph; Higgins, Emily; Griffin, Vivian; Mokotoff, Eve; MacMaster, Karen; Wolverton, Marcia; Risser, Jan; Rehman, Hafeez; Padgett, Paige; Bingham, Trista; Sey, Ekow Kwa; LaLota, Marlene; Metsch, Lisa; Forrest, David; Beck, Dano; Cardenas, Gabriel; Nemeth, Chris; Anderson, Bridget J.; Watson, Carol-Ann; Smith, Lou; Robinson, William T.; Gruber, DeAnn; Barak, Narquis; Murrill, Chris; Neaigus, Alan; Jenness, Samuel; Hagan, Holly; Reilly, Kathleen H.; Wendel, Travis; Cross, Helene; Bolden, Barbara; D'Errico, Sally; Wogayehu, Afework; Godette, Henry; Brady, Kathleen A.; Kirkland, Althea; Sifferman, Andrea; Miguelino-Keasling, Vanessa; Velasco, Al; Tovar, Veronica; Raymond, H. Fisher; De León, Sandra Miranda; Rolón-Colón, Yadira; Marzan, Melissa; Courogen, Maria; Jaenicke, Tom; Thiede, Hanne; Burt, Richard; Jia, Yujiang; Opoku, Jenevieve; Sansone, Marie; West, Tiffany; Magnus, Manya; Kuo, Irene

    2015-01-01

    According to National HIV Behavioral Surveillance system data, human immunodeficiency virus (HIV) testing increased among gay, bisexual, and other men who have sex with men from 2008 to 2011 in cities funded by the Centers for Disease Control and Prevention's Expanded Testing Initiative, suggesting that focused HIV testing initiatives might have positive effects. PMID:25352589

  3. Safety review on unit testing of safety system software of nuclear power plant

    International Nuclear Information System (INIS)

    Liu Le; Zhang Qi

    2013-01-01

    Software unit testing has an important place in the testing of safety system software of nuclear power plants, and in the wider scope of the verification and validation. It is a comprehensive, systematic process, and its documentation shall meet the related requirements. When reviewing software unit testing, attention should be paid to the coverage of software safety requirements, the coverage of software internal structure, and the independence of the work. (authors)

  4. Standard test method for initial screening of corrosion inhibiting admixtures for steel in concrete

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers a procedure for determining the effects of chemical admixtures on the corrosion of metals in concrete. This test method can be used to evaluate materials intended to inhibit chloride-induced corrosion of steel in concrete. It can also be used to evaluate the corrosivity of admixtures by themselves or in a chloride environment. This test is not applicable for emulsions. 1.2 &solely-SI-units; 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Causes of several accidents in gamma radiography testing units

    International Nuclear Information System (INIS)

    Vykrocil, L.

    1979-01-01

    Three cases are described of radiation accidents in gamma flaw-detection work-places in the West Bohemian Region. The causes of the accidents stemmed from the unsatisfactory technical condition of the materials testing equipment used and nonobservance of regulations for work with radioactive sourr.es. It is necessary for precluding similar accident to improve preventive care of gamma flaw-detection equipment and to educate personnel who would be considered for coping with the situation when control over the radiation source is lost. (Ha)

  6. Closure Report for Corrective Action Unit 261: Area 25 Test Cell A Leachfield System, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    T. M. Fitzmaurice

    2001-04-01

    The purpose of this Closure Report (CR) is to provide documentation of the completed corrective action at the Test Cell A Leachfield System and to provide data confirming the corrective action. The Test Cell A Leachfield System is identified in the Federal Facility Agreement and Consent Order (FFACO) of 1996 as Corrective Action Unit (CAU) 261. Remediation of CAU 261 is required under the FFACO (1996). CAU 261 is located in Area 25 of the Nevada Test Site (NTS) which is approximately 140 kilometers (87 miles) northwest of Las Vegas, Nevada (Figure 1). CAU 261 consists of two Corrective Action Sites (CASS): CAS 25-05-01, Leachfield; and CAS 25-05-07, Acid Waste Leach Pit (AWLP) (Figures 2 and 3). Test Cell A was operated during the 1960s and 1970s to support the Nuclear Rocket Development Station. Various operations within Building 3124 at Test Cell A resulted in liquid waste releases to the Leachfield and the AWLP. The following existing site conditions were reported in the Corrective Action Decision Document (CADD) (U.S. Department of Energy, Nevada Operations Office [DOE/NV], 1999): Soil in the leachfield was found to exceed the Nevada Division of Environmental Protection (NDEP) Action Level for petroleum hydrocarbons, the U.S. Environmental Protection Agency (EPA) preliminary remediation goals for semi volatile organic compounds, and background concentrations for strontium-90; Soil below the sewer pipe and approximately 4.5 meters (m) (15 feet [ft]) downstream of the initial outfall was found to exceed background concentrations for cesium-137 and strontium-90; Sludge in the leachfield septic tank was found to exceed the NDEP Action Level for petroleum hydrocarbons and to contain americium-241, cesium-137, uranium-234, uranium-238, potassium-40, and strontium-90; No constituents of concern (COC) were identified at the AWLP. The NDEP-approved CADD (DOWNV, 1999) recommended Corrective Action Alternative 2, ''Closure of the Septic Tank and Distribution Box

  7. Analysis of crack initiation and growth in the high level vibration test at Tadotsu

    International Nuclear Information System (INIS)

    Kassir, M.K.; Hofmayer, C.H.; Bandyopadhyay, K.K.

    1991-01-01

    A High Level Vibration Test (HLVT) Program was carried out recently on the seismic table at the Tadotsu Engineering Laboratory of Nuclear Power Engineering Center (NUPEC) in Japan. The objective of the study being performed at Brookhaven National Laboratory is to use the HLVT data to assess the accuracy and usefulness of existing methods for predicting crack initiation and growth under complex, large amplitude loading. The work to be performed as part of this effort involves: (1) analysis of the stress/strain distribution in the vicinity of the crack, including the potential for residual stresses due to the weld repair; (2) analysis of the number of load cycles required for crack initiation, including estimates of the impact of the weld repair on the crack initiation behavior; (3) analysis of crack advance as a function of applied loading (classic fatigue versus cyclic tearing) taking into account the variable amplitude loading and the possible influence of the repair; and (4) material property testing to supplement the work performed as part of the HLVT, providing the materials data necessary to perform the analysis efforts. A summary of research progress for FY 1990 is presented. 2 refs

  8. Operation of the radioactive acid-digestion test unit (RADTU)

    International Nuclear Information System (INIS)

    Blasewitz, A.G.; Allen, C.R.; Lerch, R.E.; Ely, P.C.; Richardson, G.L.

    1981-01-01

    At the Karlsruhe Nuclear Research Center, research and development work concerned with the acid digestion of combustible waste with high plutonium content is being carried out. The main objectives are the reduction of the waste volume, the recovery of the plutonium and the transformation of the process residues into a product suitable for final disposal. For this purpose an inactive demonstration plant with a throughput of 1.5 kg/h has been constructed. In the first version, the reactor of this plant was a tray reactor of the HEDL type. During test operations the sedimentation of a residue was observed on the tray. The density of this residue was higher than that of the residue suspended in the reaction acid. Experiments using tantalum oxide (D=8.4 g/cm 3 ) to simulate the plutonium oxide (D=11.5 g/cm 3 ) have verified this observation. This means that in active operation a sedimentation of plutonium oxide on the tray is to be expected. With respect to these results a new reactor was developed where the settling of the residue is avoided by appropriate design and high circulation velocity of the reaction acid. The reactor consists of a tube 50-80 mm in diameter, which is curved to form a closed loop with an arm length of about 1x1 m. Since October 1979 this ring reactor has been under inactive test operation. Its behaviour is very stable. The velocity of the reaction acid in the heater is 0.5-1 m/s. A settling of residues or tantalum oxide has not been observed. The throughput attained is comparable to that of the tray reactor but the space requirement is three times smaller, and the volume of the reaction acid four times smaller. (author)

  9. The role of Clinical Trial Units in investigator- and industry-initiated research projects.

    Science.gov (United States)

    von Niederhäusern, Belinda; Fabbro, Thomas; Pauli-Magnus, Christiane

    2015-01-01

    Six multidisciplinary competence centres (Clinical Trial Units, CTUs) in Basel, Berne, Geneva, Lausanne, St. Gallen and Zurich provide professional support to clinical researchers in the planning, implementation, conduct and evaluation of clinical studies. Through their coordinated network, these units promote high-quality, nationally harmonised and internationally standardised clinical research conduct in Switzerland. We will describe why this network has been established, how it has been successful in stilling the growing need for clinical research support, which training and education opportunities it offers, and how it created national awareness for the still-existing hurdles towards clinical research excellence in Switzerland. Taking the CTU Basel as an example, we show that a considerable number (25%) of the studies submitted for regulatory approval in 2013 were supported by the CTU, decreasing the number of findings in ethics reviews by about one-third. We conclude that these achievements, together with a Swiss national funding model for clinical research, and improved national coordination, will be critical factors to successfully position Swiss clinical research at the international forefront.

  10. The United Nations Basic Space Science Initiative (UNBSSI): A Historical Introduction

    Science.gov (United States)

    Haubold, H. J.

    2006-11-01

    Pursuant to recommendations of the Third United Nations Conference on the Exploration and Peaceful Uses of Outer Space (UNISPACE III) and deliberations of the United Nations Committee on the Peaceful Uses of Outer Space (UNCOPUOS), annual UN/European Space Agency workshops on basic space science have been held around the world since 1991. These workshops contributed to the development of astrophysics and space science, particularly in developing nations. Following a process of prioritization, the workshops identified the following elements as particularly important for international cooperation in the field: (i) operation of astronomical telescope facilities implementing TRIPOD, (ii) virtual observatories, (iii) astrophysical data systems, (iv) con-current design capabilities for the development of international space missions, and (v) theoretical astrophysics such as applications of non-extensive statistical mechanics. Beginning in 2005, the workshops are focusing on preparations for the International Heliophysical Year 2007 (IHY2007). The workshops continue to facilitate the establishment of astronomical telescope facilities as pursued by Japan and the development of low-cost, ground-based, world- wide instrument arrays as led by the IHY secretariat. Wamsteker, W., Albrecht, R. and Haubold, H.J.: Developing Basic Space Science World-Wide: A Decade of UN/ESA Workshops: Kluwer Academic Publishers, Dordrecht 2004. http://ihy2007.org http://www.unoosa.org/oosa/en/SAP/bss/ihy2007/index.html http://www.cbpf.br/GrupPesq/StatisticalPhys/biblio.htm

  11. Estimating Renewable Energy Economic Potential in the United States. Methodology and Initial Results

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Austin; Beiter, Philipp; Heimiller, Donna; Davidson, Carolyn; Denholm, Paul; Melius, Jennifer; Lopez, Anthony; Hettinger, Dylan; Mulcahy, David; Porro, Gian

    2016-08-01

    This report describes a geospatial analysis method to estimate the economic potential of several renewable resources available for electricity generation in the United States. Economic potential, one measure of renewable generation potential, may be defined in several ways. For example, one definition might be expected revenues (based on local market prices) minus generation costs, considered over the expected lifetime of the generation asset. Another definition might be generation costs relative to a benchmark (e.g., a natural gas combined cycle plant) using assumptions of fuel prices, capital cost, and plant efficiency. Economic potential in this report is defined as the subset of the available resource technical potential where the cost required to generate the electricity (which determines the minimum revenue requirements for development of the resource) is below the revenue available in terms of displaced energy and displaced capacity. The assessment is conducted at a high geospatial resolution (more than 150,000 technology-specific sites in the continental United States) to capture the significant variation in local resource, costs, and revenue potential. This metric can be a useful screening factor for understanding the economic viability of renewable generation technologies at a specific location. In contrast to many common estimates of renewable energy potential, economic potential does not consider market dynamics, customer demand, or most policy drivers that may incent renewable energy generation.

  12. Initiatives of six-sigma in an automotive ancillary unit: A case study

    Directory of Open Access Journals (Sweden)

    Pardeep Rana

    2018-06-01

    Full Text Available It is a commonly visible scenario in todays’ market, especially in small and medium sized enterpris-es (SMEs, where the focus is on quantity rather than quality. This paper explains the common high rejection problem of a SME and how the productivity levels were enhanced after the successful implementation of Six-Sigma DMAIC methodology. Once the project completion industry was able to acquire many tangible and intangible benefits, this paper offers a systematic step by step illustration of DMAIC methodology to help the other firms start similar productivity improvement initiatives.

  13. Streamlined Approach for Environmental Restoration Work Plan for Corrective Action Unit 461: Joint Test Assembly Sites and Corrective Action Unit 495: Unconfirmed Joint Test Assembly Sites Tonopah Test Range, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Jeff Smith

    1998-08-01

    This Streamlined Approach for Environmental Restoration plan addresses the action necessary for the clean closure of Corrective Action Unit 461 (Test Area Joint Test Assembly Sites) and Corrective Action Unit 495 (Unconfirmed Joint Test Assembly Sites). The Corrective Action Units are located at the Tonopah Test Range in south central Nevada. Closure for these sites will be completed by excavating and evaluating the condition of each artillery round (if found); detonating the rounds (if necessary); excavating the impacted soil and debris; collecting verification samples; backfilling the excavations; disposing of the impacted soil and debris at an approved low-level waste repository at the Nevada Test Site

  14. Healthy hospital food initiatives in the United States: time to ban sugar sweetened beverages to reduce childhood obesity.

    Science.gov (United States)

    Wojcicki, Janet M

    2013-06-01

    While childhood obesity is a global problem, the extent and severity of the problem in United States, has resulted in a number of new initiatives, including recent hospital initiatives to limit the sale of sweetened beverages and other high calorie drinks in hospital vending machines and cafeterias. These proposed policy changes are not unique to United States, but are more comprehensive in the number of proposed hospitals that they will impact. Meanwhile, however, it is advised, that these initiatives should focus on banning sugar sweetened beverages, including sodas, 100% fruit juice and sports drinks, from hospital cafeterias and vending machines instead of limiting their presence, so as to ensure the success of these programs in reducing the prevalence of childhood obesity. If US hospitals comprehensively remove sugar sweetened beverages from their cafeterias and vending machines, these programs could subsequently become a model for efforts to address childhood obesity in other areas of the world. Hospitals should be a model for health care reform in their communities and removing sugar sweetened beverages is a necessary first step. ©2013 Foundation Acta Paediatrica. Published by Blackwell Publishing Ltd.

  15. Start-up test of Fukushima Daini Nuclear Power Station Unit No.3

    International Nuclear Information System (INIS)

    Inomata, Toshio; Umezu, Akira; Kajikawa, Makoto; Koibuchi, Hiroshi; Netsu, Nobuhiko.

    1986-01-01

    In Unit 3 of the Fukushima Nuclear Power Station II (daini), a BWR power plant of output 1,100 MW, commercial operation was started in June 1985. Its start-up test was finished successfully in about nine months. That is, new equipments introduced were demonstration tested. Though the items of testing are increased, the start-up test took short time, resulting in construction period only 54.7 months of the Unit 3, the shortest in the world. During the test, there was no scramming other than the planned. Described are the following: an outline of the Unit 3, the items of its improvement and standardization, including the new equipments, preparations for the start-up test, the start-up test and its evaluation. (Mori, K.)

  16. Reducing the social gradient in smoking: initiatives in the United Kingdom.

    Science.gov (United States)

    Murray, Rachael L; McNeill, Ann

    2012-07-01

    To describe initiatives aiming to reduce the social gradient of smoking in the UK. A description of government initiatives to support smokers from low socioeconomic and other key groups, including National Health Service Stop Smoking Services and how they are seeking to support smokers to quit. The UK is employing a number of strategies to reduce smoking prevalence and is currently top of the Tobacco Control Scale in Europe but the health gap does not yet appear to be decreasing (in relation to smoking prevalence in deprived and higher income groups). More recently, efforts have been made to target smokers in more deprived groups to draw more of these smokers into the quitting process. While Stop Smoking Services are a key part of the UK's comprehensive tobacco control strategy and are reaching smokers from low socioeconomic groups, wider population strategies, such as ensuring all contacts with health-care professionals include advice to stop and the prohibition of remaining channels of tobacco marketing, are required to maximise the impact on deprived smokers. While smoking prevalence decreases among the general population are important, reducing smoking among disadvantaged groups is imperative to reduce health inequalities. It is too soon to say whether the new measures recently adopted in the UK will help to achieve this. © 2012 Australasian Professional Society on Alcohol and other Drugs.

  17. Navigating recurrent abdominal pain through clinical clues, red flags, and initial testing.

    Science.gov (United States)

    Noe, Joshua D; Li, B U K

    2009-05-01

    Recurrent abdominal pain is a common chronic complaint that presents to your office. The constant challenge is one of detecting those with organic disease from the majority who have a functional pain disorder including functional dyspepsia, irritable bowel syndrome, functional abdominal pain, and abdominal migraine. Beginning with a detailed history and physical exam, you can: 1) apply the symptom-based Rome III criteria to positively identify a functional disorder, and 2) filter these findings through the diagnostic clues and red flags that point toward specific organic disease and/or further testing. Once a functional diagnosis has been made or an organic disease is suspected, you can initiate a self-limited empiric therapeutic trial. With this diagnostic approach, you should feel confident navigating through the initial evaluation, management, and consultation referral for a child or adolescent with recurrent abdominal pain.

  18. The effects of initial testing on false recall and false recognition in the social contagion of memory paradigm.

    Science.gov (United States)

    Huff, Mark J; Davis, Sara D; Meade, Michelle L

    2013-08-01

    In three experiments, participants studied photographs of common household scenes. Following study, participants completed a category-cued recall test without feedback (Exps. 1 and 3), a category-cued recall test with feedback (Exp. 2), or a filler task (no-test condition). Participants then viewed recall tests from fictitious previous participants that contained erroneous items presented either one or four times, and then completed final recall and source recognition tests. The participants in all conditions reported incorrect items during final testing (a social contagion effect), and across experiments, initial testing had no impact on false recall of erroneous items. However, on the final source-monitoring recognition test, initial testing had a protective effect against false source recognition: Participants who were initially tested with and without feedback on category-cued initial tests attributed fewer incorrect items to the original event on the final source-monitoring recognition test than did participants who were not initially tested. These data demonstrate that initial testing may protect individuals' memories from erroneous suggestions.

  19. Out-of pile mechanical test: simulating reactivity initiated accident (RIA) of zircaloy-4 cladding tube

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myung Ho; Kim, Jun Hwan; Choi, Byoung Kwon; Jeong, Young Hwan [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2004-07-01

    The ejection or drop of a control rod in a reactivity initiated accident (RIA) causes a sudden increase in reactor power and in turn deposits a large amount of energy into the fuel. In a RIA, cladding tubes bear thermal expansion due to sudden reactivity and may fail from the resulting mechanical damage. Thus, RIA can be one of the safety margin reducers because the oxide on the tubes makes their thickness to support the load less as well as hydrides from the corrosion reduce the ductility of the tubes. In a RIA, the peak of reactor power from reactivity change is about 0.1m second and the temperature of the cladding tubes increases up to 1000 .deg. C in several seconds. Although it is hard to fully simulate the situation, several attempts to measure the change of mechanical properties under a RIA situation has done using a reduction coil, ring tension tests with high speed. This research was done to see the effect of oxide on the change of circumferential strength and ductility of Zircaloy-4 tubes in a RIA. The ring stretch tensile tests were performed with the strain rate of 1/sec and 0.01/s to simulate a transient of the cladding tube under a RIA. Since the test results of the ring tensile test are very sensitive to the lubricant, the tests were also carried out to select a suitable lubricant before the test of oxided specimens.

  20. Digital scrapbooking as a standard of care in neonatal intensive care units: initial experience.

    Science.gov (United States)

    Subhani, Muhammad T; Kanwal, Ifrah

    2012-01-01

    In this article, we describe a digital photo scrapbooking project as a standard of care for the parents of infants admitted in a neonatal intensive care unit (NICU). Photographs were taken from birth until discharge or expiry at special moments during the infant's hospitalization and used to create a digital scrapbook with daily notes by the parents. The scrapbook and original photos were provided on a CD at discharge or at expiry. Parents and their families unanimously appreciated the photos and the opportunity to record their thoughts, and considered the CDs as a lifetime treasure. Digital photo journaling could be implemented as a standard of care at other institutions with a commitment from the nursing and ancillary staff of the NICU and labor and delivery department, with possible support from volunteers.

  1. The Scope and Impact of Workplace Diversity in the United Arab Emirates – An Initial Study

    Directory of Open Access Journals (Sweden)

    Badreya Al-Jenaibi

    2011-07-01

    Full Text Available Managing workplace diversity has become a priority concern among organizations in the United Arab Emirates (UAE today. The UAE has one of the world's largest net migration rates, and the number of workers from India, the Philippines, Indonesia, Australia, the USA, among other countries, has increased significantly in recent decades (Burns, 2005. The UAE's cross-border mobility has resulted in the interaction of people with diverse language, customs and ethnic backgrounds. Although diversity has been shown to have a number of benefits, including enhanced employee creativity and competence, this recognition is often found more in theory than actual practice. Diversity can also lead to miscommunication, dysfunctional adaptation behaviors and the creation of barriers that reduce the benefits diversity can bring to the organization. Due to the nature of the UAE workplace, which is dominated by a foreign workforce, this study critically analyzes the benefits and challenges organizations face in the diverse workplaces of the United Arab Emirates. The study used a multi-method approach combining survey data from 450 surveys of foreign workers with qualitative data from interviews with native officials of organizations. It is an attempt to compare the views of UAE workplace experience from two different groups—non-native workers and native officials. The research found a generally favorable view toward workplace diversity from the perspective of surveyed employees. However, when asked more detailed questions about company policy, a significant segment of respondents expressed reservations about their employer’s ability to implement successful intercultural communication and diversity practices.

  2. INITIAL TESTS AND ACCURACY ASSESMENT OF A COMPACT MOBILE LASER SCANNING SYSTEM

    Directory of Open Access Journals (Sweden)

    K. Julge

    2016-06-01

    Full Text Available Mobile laser scanning (MLS is a faster and cost-effective alternative to static laser scanning, even though there is a slight trade-off in accuracy. This contribution describes a compact mobile laser scanning system mounted on a vehicle. The technical parameters of the used system components, i.e. a small LIDAR sensor Velodyne VLP-16 and a dual antenna GNSS/INS system Advanced Navigation Spatial Dual, are reviewed, along with the integration of these components for spatial data acquisition. Calculation principles of 3D coordinates from the real-time data of all the involved sensors are discussed. The field tests were carried out in a controlled environment of a parking lot and at different velocities. Experiments were carried out to test the ability of the GNSS/INS system to cope with difficult conditions, e.g. sudden movements due to cornering or swerving. The accuracy of the resulting MLS point cloud is evaluated with respect to high-accuracy static terrestrial laser scanning data. Problems regarding combining LIDAR, GNSS and INS sensors are outlined, as well as the initial accuracy assessments. Initial tests revealed errors related to insufficient quality of inertial data and a need for the trajectory post-processing calculations. Although this study was carried out while the system was mounted on a car, there is potential for operating the system on an unmanned aerial vehicle, all-terrain vehicle or in a backpack mode due to its relatively compact size.

  3. Analysis of crack initiation and growth in the high level vibration test at Tadotsu

    International Nuclear Information System (INIS)

    Kassir, M.K.; Park, Y.J.; Hofmayer, C.H.; Bandyopadhyay, K.K.; Shteyngart, S.

    1993-08-01

    The High Level Vibration Test data are used to assess the accuracy and usefulness of current engineering methodologies for predicting crack initiation and growth in a cast stainless steel pipe elbow under complex, large amplitude loading. The data were obtained by testing at room temperature a large scale modified model of one loop of a PWR primary coolant system at the Tadotsu Engineering Laboratory in Japan. Fatigue crack initiation time is reasonably predicted by applying a modified local strain approach (Coffin-Mason-Goodman equation) in conjunction with Miner's rule of cumulative damage. Three fracture mechanics methodologies are applied to investigate the crack growth behavior observed in the hot leg of the model. These are: the ΔK methodology (Paris law), ΔJ concepts and a recently developed limit load stress-range criterion. The report includes a discussion on the pros and cons of the analysis involved in each of the methods, the role played by the key parameters influencing the formulation and a comparison of the results with the actual crack growth behavior observed in the vibration test program. Some conclusions and recommendations for improvement of the methodologies are also provided

  4. Initial Tests and Accuracy Assesment of a Compact Mobile Laser Scanning System

    Science.gov (United States)

    Julge, K.; Ellmann, A.; Vajakas, T.; Kolka, R.

    2016-06-01

    Mobile laser scanning (MLS) is a faster and cost-effective alternative to static laser scanning, even though there is a slight trade-off in accuracy. This contribution describes a compact mobile laser scanning system mounted on a vehicle. The technical parameters of the used system components, i.e. a small LIDAR sensor Velodyne VLP-16 and a dual antenna GNSS/INS system Advanced Navigation Spatial Dual, are reviewed, along with the integration of these components for spatial data acquisition. Calculation principles of 3D coordinates from the real-time data of all the involved sensors are discussed. The field tests were carried out in a controlled environment of a parking lot and at different velocities. Experiments were carried out to test the ability of the GNSS/INS system to cope with difficult conditions, e.g. sudden movements due to cornering or swerving. The accuracy of the resulting MLS point cloud is evaluated with respect to high-accuracy static terrestrial laser scanning data. Problems regarding combining LIDAR, GNSS and INS sensors are outlined, as well as the initial accuracy assessments. Initial tests revealed errors related to insufficient quality of inertial data and a need for the trajectory post-processing calculations. Although this study was carried out while the system was mounted on a car, there is potential for operating the system on an unmanned aerial vehicle, all-terrain vehicle or in a backpack mode due to its relatively compact size.

  5. Compact Multipurpose Mobile Laser Scanning System — Initial Tests and Results

    Directory of Open Access Journals (Sweden)

    Craig Glennie

    2013-01-01

    Full Text Available We describe a prototype compact mobile laser scanning system that may be operated from a backpack or unmanned aerial vehicle. The system is small, self-contained, relatively inexpensive, and easy to deploy. A description of system components is presented, along with the initial calibration of the multi-sensor platform. The first field tests of the system, both in backpack mode and mounted on a helium balloon for real-world applications are presented. For both field tests, the acquired kinematic LiDAR data are compared with highly accurate static terrestrial laser scanning point clouds. These initial results show that the vertical accuracy of the point cloud for the prototype system is approximately 4 cm (1σ in balloon mode, and 3 cm (1σ in backpack mode while horizontal accuracy was approximately 17 cm (1σ for the balloon tests. Results from selected study areas on the Sacramento River Delta and San Andreas Fault in California demonstrate system performance, deployment agility and flexibility, and potential for operational production of high density and highly accurate point cloud data. Cost and production rate trade-offs place this system in the niche between existing airborne and tripod mounted LiDAR systems.

  6. Hematologic, hepatic, renal, and lipid laboratory monitoring after initiation of combination antiretroviral therapy in the United States, 2000-2010.

    Science.gov (United States)

    Yanik, Elizabeth L; Napravnik, Sonia; Ryscavage, Patrick; Eron, Joseph J; Koletar, Susan L; Moore, Richard D; Zinski, Anne; Cole, Stephen R; Hunt, Peter; Crane, Heidi M; Kahn, James; Mathews, William C; Mayer, Kenneth H; Taiwo, Babafemi O

    2013-06-01

    We assessed laboratory monitoring after combination antiretroviral therapy initiation among 3678 patients in a large US multisite clinical cohort, censoring participants at last clinic visit, combination antiretroviral therapy change, or 3 years. Median days (interquartile range) to first hematologic, hepatic, renal, and lipid tests were 30 (18-53), 31 (19-56), 33 (20-59), and 350 (96-1106), respectively. At 1 year, approximately 80% received more than 2 hematologic, hepatic, and renal tests consistent with guidelines. However, only 40% received 1 or more lipid tests. Monitoring was more frequent in specific subgroups, likely reflecting better clinic attendance or clinician perception of higher susceptibility to toxicities.

  7. Is Malaysian Stock Market Efficient? Evidence from Threshold Unit Root Tests

    OpenAIRE

    Qaiser Munir; Kasim Mansur

    2009-01-01

    This paper investigates the behavior of Kuala Lumpur Stock Exchange Composite Index (KLCI) for the period from 1980:1 to 2008:8 using a two-regime threshold autoregressive (TAR) model with an autoregressive unit root developed by Caner and Hansen [Threshold autoregression with a unit roots, Econometrics 69 (6) (2001) 1555-1596] which allows testing nonlinearity and nonstationarity simultaneously. Our finding indicates that the KLCI is a nonlinear series that is characterized by a unit root pr...

  8. Hydrologic resources management program and underground test area operable unit fy 1997

    Energy Technology Data Exchange (ETDEWEB)

    Smith, D. F., LLNL

    1998-05-01

    This report present the results of FY 1997 technical studies conducted by the Lawrence Livermore National Laboratory (LLNL) as part of the Hydrology and Radionuclide Migration Program (HRMP) and Underground Test Area Operable Unit (UGTA). The HRMP is sponsored by the US Department of Energy to assess the environmental (radiochemical and hydrologic) consequences of underground nuclear weapons testing at the Nevada Test Site.

  9. On the stability of the unit root test | Atil | Afrika Statistika

    African Journals Online (AJOL)

    Abstract. We propose to study, by two different approaches, Bayesian and classical, the test of the hypothesis of stationary first order autoregressive model against the random walk model. Therefore, we are going to present the classical approach and the Bayesian approach of this test says the unit root test. The principal ...

  10. Initial virtual flight test for a dynamically similar aircraft model with control augmentation system

    Directory of Open Access Journals (Sweden)

    Linliang Guo

    2017-04-01

    Full Text Available To satisfy the validation requirements of flight control law for advanced aircraft, a wind tunnel based virtual flight testing has been implemented in a low speed wind tunnel. A 3-degree-of-freedom gimbal, ventrally installed in the model, was used in conjunction with an actively controlled dynamically similar model of aircraft, which was equipped with the inertial measurement unit, attitude and heading reference system, embedded computer and servo-actuators. The model, which could be rotated around its center of gravity freely by the aerodynamic moments, together with the flow field, operator and real time control system made up the closed-loop testing circuit. The model is statically unstable in longitudinal direction, and it can fly stably in wind tunnel with the function of control augmentation of the flight control laws. The experimental results indicate that the model responds well to the operator’s instructions. The response of the model in the tests shows reasonable agreement with the simulation results. The difference of response of angle of attack is less than 0.5°. The effect of stability augmentation and attitude control law was validated in the test, meanwhile the feasibility of virtual flight test technique treated as preliminary evaluation tool for advanced flight vehicle configuration research was also verified.

  11. [A unit for emergency psychiatry and crisis intervention--concepts, structure and initial experiences].

    Science.gov (United States)

    Feuerlein, W; Bronisch, T; Fürmaier, A

    1983-03-01

    The article reports on a ward with 12 beds which has been set up for emergency cases in psychiatry or for immediate intervention in case of a crisis experienced by a patient. In the theoretical part of this article, it is explained that crisis situations are present in most of the psychiatric emergency patients. The article then goes briefly into the fundamentals of therapeutic strategy in such patients: A therapy which helps to uncover hidden conflicts, the pros and cons of therapy focussed on conflict and on supportive measures; as well as a therapy which supports and promotes the ego. This is followed by a comparison of the ward with corresponding facilities in Germany and abroad and a description of their structure, their patients and their function within a psychiatric care system. The concluding part of the article is devoted to a description of the authors' initial experiences and impressions gained during their work with the ward patients, quoting several examples.

  12. Anonymous or confidential HIV counseling and voluntary testing in federally funded testing sites--United States, 1995-1997.

    Science.gov (United States)

    1999-06-25

    Human immunodeficiency virus (HIV) counseling and voluntary testing (CT) programs have been an important part of national HIV prevention efforts since the first HIV antibody tests became available in 1985. In 1995, these programs accounted for approximately 15% of annual HIV antibody testing in the United States, excluding testing for blood donation. CT opportunities are offered to persons at risk for HIV infection at approximately 11,000 sites, including dedicated HIV CT sites, sexually transmitted disease (STD) clinics, drug-treatment centers, hospitals, and prisons. In 39 states, testing can be obtained anonymously, where persons do not have to give their name to get tested. All states provide confidential testing (by name) and have confidentiality laws and regulations to protect this information. This report compares patterns of anonymous and confidential testing in all federally funded CT programs from 1995 through 1997 and documents the importance of both types of testing opportunities.

  13. Efficient Market Hypothesis in South Africa: Evidence from Linear and Nonlinear Unit Root Tests

    Directory of Open Access Journals (Sweden)

    Andrew Phiri

    2015-12-01

    Full Text Available This study investigates the weak form efficient market hypothesis (EMH for five generalized stock indices in the Johannesburg Stock Exchange (JSE using weekly data collected from 31st January 2000 to 16th December 2014. In particular, we test for weak form market efficiency using a battery of linear and nonlinear unit root testing procedures comprising of the classical augmented Dickey-Fuller (ADF tests, the two-regime threshold autoregressive (TAR unit root tests described in Enders and Granger (1998 as well as the three-regime unit root tests described in Bec, Salem, and Carrasco (2004. Based on our empirical analysis, we are able to demonstrate that whilst the linear unit root tests advocate for unit roots within the time series, the nonlinear unit root tests suggest that most stock indices are threshold stationary processes. These results bridge two opposing contentions obtained from previous studies by concluding that under a linear framework the JSE stock indices offer support in favour of weak form market efficiency whereas when nonlinearity is accounted for, a majority of the indices violate the weak form EMH.

  14. 29 CFR 1919.28 - Unit proof tests-cranes and gear accessory thereto.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Unit proof tests-cranes and gear accessory thereto. 1919.28... Loads; Heat Treatment; Competent Persons § 1919.28 Unit proof tests—cranes and gear accessory thereto. (a) Except as noted in paragraph (e) of this section, cranes and other hoisting machines, together...

  15. 77 FR 38857 - Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Normal...

    Science.gov (United States)

    2012-06-29

    ... Filtration and Adsorption Units of Normal Atmosphere Cleanup Systems in Light-Water- Cooled Nuclear Power... Criteria for Air Filtration and Adsorption Units of Normal Atmosphere Cleanup Systems in Light-Water-Cooled... draft regulatory guide (DG), DG-1280, ``Design, Inspection, and Testing Criteria for Air Filtration and...

  16. An analysis of unit tests of a flight software product line

    NARCIS (Netherlands)

    Ganesan, D.; Lindvall, M.; McComas, D.; Bartholomew, M.; Slegel, S.; Medina, B.; Krikhaar, R.; Verhoef, C.; Dharmalingam, G.; Montgomery, L.P.

    2013-01-01

    This paper presents an analysis of the unit testing approach developed and used by the Core Flight Software System (CFS) product line team at the NASA Goddard Space Flight Center (GSFC). The goal of the analysis is to understand, review, and recommend strategies for improving the CFS' existing unit

  17. "Individualized Science" Field Test Findings and Recommendations, the Hooke Unit. Appendix A.

    Science.gov (United States)

    Loue, William E., III

    This informal report contains the findings and recommendations resulting from the field test of the Hooke Unit of the "Individualized Science" program. Data were collected from three schools. Because of an unusual number of weaknesses ranging from formal inconsistencies to manipulative deficiencies, it was concluded that the Hooke Unit is somewhat…

  18. United States Nuclear Tests, July 1945 through September 1992, December 2000

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Nevada Operations Office

    2000-12-01

    This document list chronologically and alphabetically by name all nuclear tests and simultaneous detonations conducted by the United States from July 1945 through September 1992. Revision 15, dated December 2000.

  19. Description of work for 100-DR-2 Operable Unit Vadose Drilling/test pits

    International Nuclear Information System (INIS)

    Naiknimbalkar, N.

    1993-01-01

    This report describes the scope of work for the boreholes/test pits of the 100-DR-2 Operable Unit. Sampling and field activities include: Soil screening; geologic sampling; soil sampling (physical property); analytical sampling and depths; and geophysical logging

  20. United States Nuclear Tests, July 1945 through September 1992, September 2015

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2015-09-01

    This document lists chronologically and alphabetically by name all nuclear tests and simultaneous detonations conducted by the United States from July 1945 through September 1992. This is Revision 16, dated September 2015.

  1. The contribution to site core damage frequency from independent occurrences of initiators in two or more units: How low is it?

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong-San; Park, Jin Hee; Lim, Ho Gon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Stutzke estimated the site risk by summing the contribution from common cause initiators and the contribution from single-unit initiators. He considered some kinds of multi-unit accident sequences caused by single-unit initiators. However, the contribution from independent occurrences of initiators in two or more units at a site was not taken into account. The purpose of this study is to estimate the contribution to site core damage frequency (CDF) from simultaneous occurrences of independent initiators in two or more units at the same site. Some assumptions and methods used in this analysis are firstly described, and the results and conclusions of the analysis are described. In this study, the contribution to site core damage frequency (CDF) from simultaneous occurrences of independent initiators in two or more units at the same site was estimated. A Korean six-unit site was selected as the reference site and the at-power internal events Level 1 PSA model for an OPR1000 unit at the reference site was used as the base model, and was modified to deal with some major dependencies between units at the site. Specifically, the availability of the AAC D/G, dependencies between offsite power recovery actions in different unis, and inter-unit CCF modeling for risk-significant components such as diesel generators were taken into account. As a result, the sum of dual-unit CDF due to independent occurrences of initiators in two units at the reference site was estimated to be sufficiently low to be neglected.

  2. Mobile Landing Platform with Core Capability Set (MLP w/CCS): Combined Initial Operational Test and Evaluation and Live Fire Test and Evaluation Report

    Science.gov (United States)

    2015-07-01

    SUBTITLE Mobile Landing Platform with Core Capability Set (MLP w/CCS) Combined Initial Operational Test and Evaluation ( IOT &E) and Live Fire Test and...based on data from a series of integrated test events, a dedicated end-to-end Initial Operational Test and Evaluation ( IOT &E), and two Marine Corps...Internally Transportable Vehicles (ITVs).   ii the LMSR to anchor within a few miles of the shore. Using MLP (CCS), the equipment is transported ashore

  3. Methods for monitoring the initial load to critical in the fast test reactor

    International Nuclear Information System (INIS)

    Johnson, D.L.

    1975-08-01

    Conventional symmetric fuel loadings for the initial loading to critical of the Fast Test Reactor (FTR) are predicted to be more time consuming than asymmetric or trisector loadings. Potentially significant time savings can be realized by the latter, since adequate intermediate assessments of neutron multiplication can be made periodically without control rod reconnection in all trisectors. Experimental simulation of both loading schemes was carried out in the Reverse Approach to Critical (RAC) experiments in the Fast Test Reactor-Engineering Mockup Critical facility. Analyses of these experiments indicated that conventional source multiplication methods can be applied for monitoring either a symmetric or asymmetric fuel loading scheme equally well provided that detection efficiency corrections are employed. Methods for refining predictions of reactivity and count rates for the stages in a load to critical were also investigated. (auth)

  4. United States-Mexico cross-border health insurance initiatives: Salud Migrante and Medicare in Mexico.

    Science.gov (United States)

    Vargas Bustamante, Arturo; Laugesen, Miriam; Caban, Mabel; Rosenau, Pauline

    2012-01-01

    While U.S. health care reform will most likely reduce the overall number of uninsured Mexican-Americans, it does not address challenges related to health care coverage for undocumented Mexican immigrants, who will remain uninsured under the measures of the reform; documented low-income Mexican immigrants who have not met the five-year waiting period required for Medicaid benefits; or the growing number of retired U.S. citizens living in Mexico, who lack easy access to Medicare-supported services. This article reviews two promising binational initiatives that could help address these challenges-Salud Migrante and Medicare in Mexico; discusses their prospective applications within the context of U.S. health care reform; and identifies potential challenges to their implementation (legal, political, and regulatory), as well as the possible benefits, including coverage of uninsured Mexican immigrants, and their integration into the U.S. health care system (through Salud Migrante), and access to lower-cost Medicare-supported health care for U.S. retirees in Mexico (Medicare in Mexico).

  5. 78 FR 63516 - Initial Test Program of Emergency Core Cooling Systems for New Boiling-Water Reactors

    Science.gov (United States)

    2013-10-24

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0134] Initial Test Program of Emergency Core Cooling....79.1, ``Initial Test Program of Emergency Core Cooling Systems for New Boiling-Water Reactors.'' This... emergency core cooling systems (ECCSs) for boiling- water reactors (BWRs) whose licenses are issued after...

  6. 40 CFR 63.9915 - What test methods and other procedures must I use to demonstrate initial compliance with dioxin...

    Science.gov (United States)

    2010-07-01

    ... must I use to demonstrate initial compliance with dioxin/furan emission limits? 63.9915 Section 63.9915....9915 What test methods and other procedures must I use to demonstrate initial compliance with dioxin... limit for dioxins/furans in Table 1 to this subpart, you must follow the test methods and procedures...

  7. 40 CFR 63.7940 - By what date must I conduct performance tests or other initial compliance demonstrations?

    Science.gov (United States)

    2010-07-01

    ... compliance is not demonstrated using a performance test or design evaluation, you must demonstrate initial... performance tests or other initial compliance demonstrations? 63.7940 Section 63.7940 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS...

  8. Initial evaluation of the radioecological situation at the Semipalatinsk Test Site in the Republic of Kazakhstan

    Energy Technology Data Exchange (ETDEWEB)

    Voigt, G.; Semiochkina, N. [GSF - Forschungszentrum fuer Umwelt und Gesundheit Neuherberg GmbH, Oberschleissheim (Germany). Inst. fuer Strahlenschutz

    1998-12-31

    The Semipalatinsk Test Site (STS) located in the Republic of Kazakhstan (Figure 1.1) was one of the major nuclear weapon test sites of the former Soviet Union. At the site, four hundred fifty six nuclear explosions took place between 1949 and 1989 within the STS (Mikhailov et al. 1996; Dubasov et al. 1994a), resulting in radioactive contamination both within and around the STS. Incidences of radiation related illnesses in such areas may be higher than normal levels (Burkhart 1996). Published estimates of the resulting dose to the public vary according to the source, but an independent study (Grosche 1996) indicated that as many as 30,000-40,000 people could have been exposed to an average dose of 1.6 Sv (160 rem) or more (mainly due to short-lived radionuclides such as {sup 131}I). A detailed international assessment of the impact of these tests on the local population has not yet been undertaken. A current investigation under the acronym, RADTEST, includes an evaluation of Semipalatinsk as part of a broad review of internal and external doses to people arising from nuclear tests at many different sites in the world. In the context of the European Commission funded project RESTORE (Restoration Strategy for Radioactive Contaminated Ecosystems) an attempt is being made to assess the present radiolecological situation in the STS. This initial report collates currently available data published in Russian-language literature and internal CIS reports, reports from Europe and the USA, and other international literature. In this initial evaluation, only an overview of published data made available to the RESTORE project is provided and briefly discussed. In addition, further assessments including experimental work are suggested. Additional sources of data will be pursued and will be integrated with experimental results in the final evaluation report. (orig.)

  9. Initial evaluation of the radioecological situation at the Semipalatinsk Test Site in the Republic of Kazakhstan

    International Nuclear Information System (INIS)

    Voigt, G.; Semiochkina, N.

    1998-01-01

    The Semipalatinsk Test Site (STS) located in the Republic of Kazakhstan (Figure 1.1) was one of the major nuclear weapon test sites of the former Soviet Union. At the site, four hundred fifty six nuclear explosions took place between 1949 and 1989 within the STS (Mikhailov et al. 1996; Dubasov et al. 1994a), resulting in radioactive contamination both within and around the STS. Incidences of radiation related illnesses in such areas may be higher than normal levels (Burkhart 1996). Published estimates of the resulting dose to the public vary according to the source, but an independent study (Grosche 1996) indicated that as many as 30,000-40,000 people could have been exposed to an average dose of 1.6 Sv (160 rem) or more (mainly due to short-lived radionuclides such as 131 I). A detailed international assessment of the impact of these tests on the local population has not yet been undertaken. A current investigation under the acronym, RADTEST, includes an evaluation of Semipalatinsk as part of a broad review of internal and external doses to people arising from nuclear tests at many different sites in the world. In the context of the European Commission funded project RESTORE (Restoration Strategy for Radioactive Contaminated Ecosystems) an attempt is being made to assess the present radiolecological situation in the STS. This initial report collates currently available data published in Russian-language literature and internal CIS reports, reports from Europe and the USA, and other international literature. In this initial evaluation, only an overview of published data made available to the RESTORE project is provided and briefly discussed. In addition, further assessments including experimental work are suggested. Additional sources of data will be pursued and will be integrated with experimental results in the final evaluation report. (orig.)

  10. Providing Transthoracic Echocardiography Training for Intensive Care Unit Trainees: An Educational Improvement Initiative.

    Science.gov (United States)

    Kuza, Catherine M; Hanifi, M Tariq; Koç, Melissa; Stopfkuchen-Evans, Matthias

    2018-04-09

    Transthoracic echocardiography (TTE) is important in the management of critically ill patients, yet it has not been incorporated into many residency programs' curricula. Our objective is to determine if trainees undergoing a 60-minute training session on TTE have improved knowledge, ultrasound skills, and increases the utilization of TTE during their rotation in the intensive care unit (ICU). We will also compare the results of participants with prior TTE exposure to TTE-naïve trainees. Our hypothesis is that after the training, participants' will have improved knowledge and ultrasound skills compared to before training. Our secondary hypotheses are that TTE-naïve trainees will have greater improvements in knowledge scores compared to those who have had prior TTE experience and trainees will increase their use of TTE in the ICU. Single-center, prospective trial. Brigham and Women's Hospital (academic hospital). Residents and fellows rotating through the ICU, at any level of postgraduate training. Forty-two trainees participated in the study. Statistically significant improvement after training was observed for all multiple choice questions (MCQ) and practical assessments (p < 0.001). When assessing the differences in score improvement between TTE-experienced versus TTE-naïve users, mean score improvements were notably higher for TTE-naïve participants (MCQ: 28.2 ± 11.6; echo clinical: 48.6 ± 23.4) compared to TTE-experienced users (MCQ: 18.6 ± 13.5, p = 0.01; echo clinical: 38.3 ± 30.2, p = 0.04). A short didactic presentation on TTE use may be useful in teaching ICU trainees basic TTE skills and encouraging the use of bedside TTE in the ICU. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  11. Are Current Accounts of Asian Economies Mean-reverting?: Nonlinear Unit Root Test Approach

    Directory of Open Access Journals (Sweden)

    Bonghan Kim

    2005-12-01

    Full Text Available This paper tests the mean reverting property of current account in the financial crisis-affected 5 counties of southeast Asia using nonlinear unit root tests of Park and shintani(2004. Our approach is based on the idea that a conventional unit root test has lower power in detecting the nonlinear mean reverting behavior if the current account follows a nonlinear mean reversion process. We obtained following empirical results. First, for the pre-crisis period (1981Q1-1996Q4, the current accounts of Indonesia, Malaysia and Philippines are mean-reverting but those of Korea and Thailand are not mean-reverting. Second, for the full sample period (1981Q1-2003Q4, the ADF test fails to reject the unit root of the current account in all countries except Philippines. However, unit root is rejected in favor of nonlinear mean reversion except Thailand. This nonlinear unit root test result implies that crisis-affected Asian countries except Thailand have sustainable paths of current accounts. Third, when the current accounts of East Asian countries are nonlinear mean-reverting, the mean reverting process can be well described by the ESTAR model, instead of the DTAR or DLSTAR model. The nonlinear unit root test results imply smooth nonlinear mean-reversion behaviors of East Asian current accounts. Finally, the shape of estimated impulse response functions becomes steeper as the size of shock increases, which is the very characteristic of the nonlinear process.

  12. Testing iOS apps with HadoopUnit rapid distributed GUI testing

    CERN Document Server

    Tilley, Scott

    2014-01-01

    Smartphone users have come to expect high-quality apps. This has increased the importance of software testing in mobile software development. Unfortunately, testing apps-particularly the GUI-can be very time-consuming. Exercising every user interface element and verifying transitions between different views of the app under test quickly becomes problematic. For example, execution of iOS GUI test suites using Apple's UI Automation framework can take an hour or more if the app's interface is complicated. The longer it takes to run a test, the less frequently the test can be run, which in turn re

  13. Initial screening test for blunt cerebrovascular injury: Validity assessment of whole-body computed tomography.

    Science.gov (United States)

    Laser, Adriana; Kufera, Joseph A; Bruns, Brandon R; Sliker, Clint W; Tesoriero, Ronald B; Scalea, Thomas M; Stein, Deborah M

    2015-09-01

    grades (55% vs 13%, respectively; P < .001). Grading was upgraded 8% of the time and downgraded 25%. WBCT holds promise as a rapid screening test for BCVI in the patient with polytrauma to identify injuries in the early stage of the trauma evaluation, thus allowing more rapid initiation of treatment. In addition, in those patients with high risk for BCVI but whose WBCT results are negative for BCVI, neck CTA should be considered to more confidently exclude low-grade injuries. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Physician-initiated courtesy MODS testing for TB and MDR-TB diagnosis and patient management.

    Science.gov (United States)

    Nic Fhogartaigh, C J; Vargas-Prada, S; Huancaré, V; Lopez, S; Rodríguez, J; Moore, D A J

    2008-05-01

    Laboratorio de Investigación de Enfermedades Infecciosas, Universidad Peruana Cayetano Heredia (UPCH) and government health centres, Lima, Peru. To evaluate the contribution of unselected (courtesy) microscopic observation drug susceptibility (MODS) testing to the diagnosis and/or drug susceptibility testing (DST) of tuberculosis and their subsequent impact upon patient management. Retrospective database analysis and case note review of MODS culture-positive cases. Mycobacterium tuberculosis was isolated in 28.9% of 225 samples (209 patients); 22.2% of 63 positive cases were multidrug-resistant. In 58 MODS culture-positive cases with follow-up data available, MODS provided culture confirmation of diagnosis, DST or both in 82.8%, before any standard method. In 41.4%, this result should have prompted a modification in patient management. Delays between laboratory result and initiation or change of treatment, where applicable, took on average 42 and 64 days, respectively, of which a delay of respectively 17 and 48 days occurred after the receipt of results by the health facility. MODS provides important data for clinical management within a meaningful timeframe and should contribute positively to patient outcomes due to earlier initiation of appropriate therapy. Although clinicians may successfully select patients likely to benefit from MODS, ongoing work is required to identify optimal implementation of the assay and to reduce logistical and health system derived delays.

  15. Panel Unit Root Tests by Combining Dependent Values: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Xuguang Sheng

    2011-01-01

    Full Text Available We conduct a systematic comparison of the performance of four commonly used value combination methods applied to panel unit root tests: the original Fisher test, the modified inverse normal method, Simes test, and the modified truncated product method (TPM. Our simulation results show that under cross-section dependence the original Fisher test is severely oversized, but the other three tests exhibit good size properties. Simes test is powerful when the total evidence against the joint null hypothesis is concentrated in one or very few of the tests being combined, but the modified inverse normal method and the modified TPM have good performance when evidence against the joint null is spread among more than a small fraction of the panel units. These differences are further illustrated through one empirical example on testing purchasing power parity using a panel of OECD quarterly real exchange rates.

  16. On the non-existence of a Bartlett correction for unit root tests

    DEFF Research Database (Denmark)

    Jensen, Jens Ledet; Wood, Andrew T.A.

    1997-01-01

    There has been considerable recent interest in testing for a unit root in autoregressive models, especially in the context of cointegration models in econometrics. The likelihood ratio test for a unit root has non-standard asymptotic behaviour. In particular, when the errors are Gaussian, the lim...... for improved distributional approximations, and the question of whether W admits a Bartlett correction is of interest. In this note we establish that a Bartlett correction does not exist in the simplest unit root model. © 1997 Elsevier Science B.V....

  17. Indigenous unit for bending and twisting tests of ultra-thin films on a flexible substrate

    Science.gov (United States)

    D'souza, Slavia Deeksha; Hazarika, Pratim; Prakasarao, Ch Surya; Kovendhan, M.; Kumar, R. Arockia; Joseph, D. Paul

    2018-04-01

    An indigenous unit is designed to test the stability of thin films deposited on to a flexible substrate by inducing a required number of bending and twisting under specific conditions. The unit is designed using aluminum and automated by sending pulse width modulated signals to servo motors using ATmega328 microcontroller. We have tested the unit by imparting stress on to a commercial ITO film deposited on a PET substrate. After a definite number of bending and twisting cycles, the electrical and surface properties are studied and the results are discussed.

  18. Design, fabrication, and dynamic testing of a V-groove radiator mechanical development unit

    Science.gov (United States)

    Petrick, S. Walter; Bard, Steven

    1988-01-01

    This paper describes the design, fabrication, and dynamic testing of a V-groove radiator development unit. The intended goal was to survive the dynamic environment of the Mars Observer mission. The development unit was designed to achieve a temperature of 80 K with a heat load of about 80 milliwatts. An analysis was performed to predict the thermal performance of the development unit. The radiator with a mass mockup of a Gamma Ray Spectrometer detector, the most massive of the candidate Mars Observer instrument detectors (1.7 Kg), passed vibration and acoustic testing to the Mars Observer requirements in effect at that time.

  19. Documentation for initial testing and inspections of Beneficial Uses Shipping System (BUSS) Cask

    International Nuclear Information System (INIS)

    Lundeen, J.E.

    1994-01-01

    The purpose of this report is to compile data generated during the initial tests and inspections of the Beneficial Uses Shipping System (BUSS) Cask. In addition, this report will verify that the testing criteria identified in section 8.1 of the BUSS Cask Safety Analysis Report for Packaging (SARP) was met. The BUSS Cask Model R-1 is a type B shipping container used for shipment of radioactive cesium-137 and strontium-90 capsules to Waste Encapsulation and Storage Facility (WESF). The BUSS Cask body and lid are each one-piece forgings fabricated from ASTM A473, Type 304 stainless steel. The primary purpose of the BUSS Cask is to provide shielding and confinement as well as impact, puncture, and thermal protection for the capsules under both normal and accident conditions. Chapter 8 of the BUSS Cask SARP requires several acceptance tests and inspections, each intended to evaluate the performance of different components of the BUSS Cask system, to be performed before its first use. The results of the tests and inspections required are included in this document

  20. Provider-initiated HIV testing and counselling for TB patients and suspects in Nairobi, Kenya.

    Science.gov (United States)

    Odhiambo, J; Kizito, W; Njoroge, A; Wambua, N; Nganga, L; Mburu, M; Mansoer, J; Marum, L; Phillips, E; Chakaya, J; De Cock, K M

    2008-03-01

    Integrated tuberculosis (TB) and human immunodeficiency virus (HIV) services in a resource-constrained setting. Pilot provider-initiated HIV testing and counselling (PITC) for TB patients and suspects. Through partnerships, resources were mobilised to establish and support services. After community sensitisation and staff training, PITC was introduced to TB patients and then to TB suspects from December 2003 to December 2005. Of 5457 TB suspects who received PITC, 89% underwent HIV testing. Although not statistically significant, TB suspects with TB disease had an HIV prevalence of 61% compared to 63% for those without. Of the 614 suspects who declined HIV testing, 402 (65%) had TB disease. Of 2283 patients referred for cotrimoxazole prophylaxis, 1951 (86%) were enrolled, and of 1727 patients assessed for antiretroviral treatment (ART), 1618 (94%) were eligible and 1441 (83%) started treatment. PITC represents a paradigm shift and is feasible and acceptable to TB patients and TB suspects. Clear directives are nevertheless required to change practice. When offered to TB suspects, PITC identifies large numbers of persons requiring HIV care. Community sensitisation, staff training, multitasking and access to HIV care contributed to a high acceptance of HIV testing. Kenya is using this experience to inform national response and advocate wide PITC implementation in settings faced with the TB-HIV epidemic.

  1. Initial results for a 170 GHz high power ITER waveguide component test stand

    Science.gov (United States)

    Bigelow, Timothy; Barker, Alan; Dukes, Carl; Killough, Stephen; Kaufman, Michael; White, John; Bell, Gary; Hanson, Greg; Rasmussen, Dave

    2014-10-01

    A high power microwave test stand is being setup at ORNL to enable prototype testing of 170 GHz cw waveguide components being developed for the ITER ECH system. The ITER ECH system will utilize 63.5 mm diameter evacuated corrugated waveguide and will have 24 >150 m long runs. A 170 GHz 1 MW class gyrotron is being developed by Communications and Power Industries and is nearing completion. A HVDC power supply, water-cooling and control system has been partially tested in preparation for arrival of the gyrotron. The power supply and water-cooling system are being designed to operate for >3600 second pulses to simulate the operating conditions planned for the ITER ECH system. The gyrotron Gaussian beam output has a single mirror for focusing into a 63.5 mm corrugated waveguide in the vertical plane. The output beam and mirror are enclosed in an evacuated duct with absorber for stray radiation. Beam alignment with the waveguide is a critical task so a combination of mirror tilt adjustments and a bellows for offsets will be provided. Analysis of thermal patterns on thin witness plates will provide gyrotron mode purity and waveguide coupling efficiency data. Pre-prototype waveguide components and two dummy loads are available for initial operational testing of the gyrotron. ORNL is managed by UT-Battelle, LLC, for the U.S. Dept. of Energy under Contract DE-AC-05-00OR22725.

  2. INITIAL TEST WELL CONDITIONING AT NOPAL I URANIUM DEPOSIT, SIERRA PENA BLANCA, CHIHUAHUA, MEXICO

    Energy Technology Data Exchange (ETDEWEB)

    R.D. Oliver; J.C. Dinsmoor; S.J. Goldstein; I. Reyes; R. De La Garza

    2005-07-11

    Three test wells, PB-1, PB-2, and PB-3, were drilled at the Nopal I uranium deposit as part of a natural analogue study to evaluate radionuclide transport processes during March-April 2003. The initial pumping to condition the wells was completed during December 2003. The PB-1 well, drilled immediately adjacent to the Nopal I ore body, was continuously cored to a depth of 250 m, terminating 20 m below the top of the measured water level. The PB-2 and PB-3 wells, which were drilled on opposite sides of PB-1 at a radial distance of approximately 40 to 50 m outside of the remaining projected ore body, were also drilled to about 20 m below the top of the measured water level. Each test well was completed with 4-inch (10.2-cm) diameter PVC casing with a slotted liner below the water table. Initial conditioning of all three wells using a submersible pump at low pump rates [less than 1 gallon (3.8 1) per minute] resulted in measurable draw down and recoveries. The greatest drawdown ({approx}15 m) was observed in PB-2, whereas only minor (<1 m) drawdown occurred in PB-3. For PB-1 and PB-2, the water turbidity decreased as the wells were pumped and the pH values decreased, indicating that the contamination from the drilling fluid was reduced as the wells were conditioned. Test wells PB-1 and PB-2 showed increased inflow after several borehole volumes of fluid were removed, but their inflow rates remained less that the pumping rate. Test well PB-3 showed the smallest drawdown and least change in pH and conductivity during initial pumping and quickest recovery with a rise in measured water level after conditioning. The 195 gallons (750 l) of water pumped from PB-3 during conditioning was discharged through a household sponge. That sponge showed measurable gamma radiation, which decayed to background values in less than 12 hours. Preliminary interpretations include filtration of a radioisotope source with a short half-life or of a radioisotope that volatized as the sponge

  3. INITIAL TEST WELL CONDITIONING AT NOPAL I URANIUM DEPOSIT, SIERRA PENA BLANCA, CHIHUAHUA, MEXICO

    International Nuclear Information System (INIS)

    Oliver, R.D.; Dinsmoor, J.C.; Goldstein, S.J.; Reyes, I.; De La Garza, R.

    2005-01-01

    Three test wells, PB-1, PB-2, and PB-3, were drilled at the Nopal I uranium deposit as part of a natural analogue study to evaluate radionuclide transport processes during March-April 2003. The initial pumping to condition the wells was completed during December 2003. The PB-1 well, drilled immediately adjacent to the Nopal I ore body, was continuously cored to a depth of 250 m, terminating 20 m below the top of the measured water level. The PB-2 and PB-3 wells, which were drilled on opposite sides of PB-1 at a radial distance of approximately 40 to 50 m outside of the remaining projected ore body, were also drilled to about 20 m below the top of the measured water level. Each test well was completed with 4-inch (10.2-cm) diameter PVC casing with a slotted liner below the water table. Initial conditioning of all three wells using a submersible pump at low pump rates [less than 1 gallon (3.8 1) per minute] resulted in measurable draw down and recoveries. The greatest drawdown (∼15 m) was observed in PB-2, whereas only minor (<1 m) drawdown occurred in PB-3. For PB-1 and PB-2, the water turbidity decreased as the wells were pumped and the pH values decreased, indicating that the contamination from the drilling fluid was reduced as the wells were conditioned. Test wells PB-1 and PB-2 showed increased inflow after several borehole volumes of fluid were removed, but their inflow rates remained less that the pumping rate. Test well PB-3 showed the smallest drawdown and least change in pH and conductivity during initial pumping and quickest recovery with a rise in measured water level after conditioning. The 195 gallons (750 l) of water pumped from PB-3 during conditioning was discharged through a household sponge. That sponge showed measurable gamma radiation, which decayed to background values in less than 12 hours. Preliminary interpretations include filtration of a radioisotope source with a short half-life or of a radioisotope that volatized as the sponge dried

  4. A retrospective explanatory case study of the implementation of a bleeding management quality initiative, in an Australian cardiac surgery unit.

    Science.gov (United States)

    Pearse, Bronwyn Louise; Rickard, Claire M; Keogh, Samantha; Lin Fung, Yoke

    2018-03-09

    Bleeding management in cardiac surgery is challenging. Many guidelines exist to support bleeding management; however, literature demonstrates wide variation in practice. In 2012, a quality initiative was undertaken at The Prince Charles Hospital, Australia to improve bleeding management for cardiac surgery patients. The implementation of the quality initiative resulted in significant reductions in the incidence of blood transfusion, re-exploration for bleeding; superficial leg and chest wound infections; length of hospital stay, and cost. Given the success of the initiative, we sought to answer the question; "How and why was the process of implementing a bleeding management quality initiative in the cardiac surgery unit successful, and sustainable?" A retrospective explanatory case study design was chosen to explore the quality initiative. Analysis of the evidence was reviewed through phases of the 'Knowledgeto Action' planned change model. Data was derived from: (1) document analysis, (2) direct observation of the local environment, (3) clinical narratives from interviews, and analysed with a triangulation approach. The study period extended from 10/2011 to 6/2013. Results demonstrated the complexity of changing practice, as well as the significant amount of dedicated time and effort required to support individual, department and system wide change. Results suggest that while many clinicians were aware of the potential to apply improved practice, numerous barriers and challenges needed to be overcome to implement change across multiple disciplines and departments. The key successful components of the QI were revealed through the case study analysis as: (1) an appropriately skilled project manager to facilitate the implementation process; (2) tools to support changes in workflow and decision making including a bleeding management treatment algorithm with POCCTs; (3) strong clinical leadership from the multidisciplinary team and; (4) the evolution of the project

  5. Institutionalizing provider-initiated HIV testing and counselling for children: an observational case study from Zambia.

    Science.gov (United States)

    Mutanga, Jane N; Raymond, Juliette; Towle, Megan S; Mutembo, Simon; Fubisha, Robert Captain; Lule, Frank; Muhe, Lulu

    2012-01-01

    Provider-initiated testing and counselling (PITC) is a priority strategy for increasing access for HIV-exposed children to prevention measures, and infected children to treatment and care interventions. This article examines efforts to scale-up paediatric PITC at a second-level hospital located in Zambia's Southern Province, and serving a catchment area of 1.2 million people. Our retrospective case study examined best practices and enabling factors for rapid institutionalization of PITC in Livingstone General Hospital. Methods included clinical observations, key informant interviews with programme management, and a desk review of hospital management information systems (HMIS) uptake data following the introduction of PITC. After PITC roll-out, the hospital experienced considerably higher testing uptake. In a 36-month period following PITC institutionalization, of total inpatient children eligible for PITC (n = 5074), 98.5% of children were counselled, and 98.2% were tested. Of children tested (n = 4983), 15.5% were determined HIV-infected; 77.6% of these results were determined by DNA polymerase chain reaction (PCR) testing in children under the age of 18 months. Of children identified as HIV-infected in the hospital's inpatient and outpatient departments (n = 1342), 99.3% were enrolled in HIV care, including initiation on co-trimoxazole prophylaxis. A number of good operational practices and enabling factors in the Livingstone General Hospital experience can inform rapid PITC institutionalization for inpatient and outpatient children. These include the placement of full-time nurse counsellors at key areas of paediatric intake, who interface with patients immediately and conduct testing and counselling. They are reinforced through task-shifting to peer counsellors in the wards. Nurse counsellor capacity to draw specimen for DNA PCR for children under 18 months has significantly enhanced early infant diagnosis. The hospital's bolstered antiretroviral

  6. Institutionalizing provider-initiated HIV testing and counselling for children: an observational case study from Zambia.

    Directory of Open Access Journals (Sweden)

    Jane N Mutanga

    Full Text Available BACKGROUND: Provider-initiated testing and counselling (PITC is a priority strategy for increasing access for HIV-exposed children to prevention measures, and infected children to treatment and care interventions. This article examines efforts to scale-up paediatric PITC at a second-level hospital located in Zambia's Southern Province, and serving a catchment area of 1.2 million people. METHODS AND PRINCIPAL FINDINGS: Our retrospective case study examined best practices and enabling factors for rapid institutionalization of PITC in Livingstone General Hospital. Methods included clinical observations, key informant interviews with programme management, and a desk review of hospital management information systems (HMIS uptake data following the introduction of PITC. After PITC roll-out, the hospital experienced considerably higher testing uptake. In a 36-month period following PITC institutionalization, of total inpatient children eligible for PITC (n = 5074, 98.5% of children were counselled, and 98.2% were tested. Of children tested (n = 4983, 15.5% were determined HIV-infected; 77.6% of these results were determined by DNA polymerase chain reaction (PCR testing in children under the age of 18 months. Of children identified as HIV-infected in the hospital's inpatient and outpatient departments (n = 1342, 99.3% were enrolled in HIV care, including initiation on co-trimoxazole prophylaxis. A number of good operational practices and enabling factors in the Livingstone General Hospital experience can inform rapid PITC institutionalization for inpatient and outpatient children. These include the placement of full-time nurse counsellors at key areas of paediatric intake, who interface with patients immediately and conduct testing and counselling. They are reinforced through task-shifting to peer counsellors in the wards. Nurse counsellor capacity to draw specimen for DNA PCR for children under 18 months has significantly enhanced early

  7. Income and CO2 emissions: Evidence from panel unit root and cointegration tests

    International Nuclear Information System (INIS)

    Lee, C.-C.; Lee, J.-D.

    2009-01-01

    This paper re-investigates the stationarity properties of per capita carbon dioxide (CO 2 ) emissions and real Gross Domestic Product (GDP) per capita for 109 countries within seven regional panel sets covering 1971-2003. We apply the recent unit-root test of the panel seemingly unrelated regressions augmented Dickey-Fuller (SURADF) test developed by Breuer et al. [2001. Misleading inferences from panel unit-root tests with an illustration from purchasing power parity. Review of International Economics 9, 482-493; 2002. Series-specific unit-root tests with panel data, Oxford Bulletin of Economics and Statistics 64, 527-546]. The panel SURADF test accounts for the presence of cross-country correlations in the data, and the parameters in the panel specification vary across countries. More importantly, this test allows us to identify how many and which members of the panel contain a unit root. Overall, our empirical results illustrate that real GDP and CO 2 emissions in these countries are a mixture of I(0) and I(1) processes, and that the traditional panel unit-root tests could lead to misleading inferences as well as the conduct of cointegration analysis being perhaps inappropriate. The results of our analysis carry critical implications for the modeling of CO 2 emissions and GDP because of the different orders of integration for the two variables

  8. Well Completion Report for Corrective Action Unit 443 Central Nevada Test Area Nye County, Nevada

    International Nuclear Information System (INIS)

    2009-01-01

    The drilling program described in this report is part of a new corrective action strategy for Corrective Action Unit (CAU) 443 at the Central Nevada Test Area (CNTA). The drilling program included drilling two boreholes, geophysical well logging, construction of two monitoring/validation (MV) wells with piezometers (MV-4 and MV-5), development of monitor wells and piezometers, recompletion of two existing wells (HTH-1 and UC-1-P-1S), removal of pumps from existing wells (MV-1, MV-2, and MV-3), redevelopment of piezometers associated with existing wells (MV-1, MV-2, and MV-3), and installation of submersible pumps. The new corrective action strategy includes initiating a new 5-year proof-of-concept monitoring period to validate the compliance boundary at CNTA (DOE 2007). The new 5-year proof-of-concept monitoring period begins upon completion of the new monitor wells and collection of samples for laboratory analysis. The new strategy is described in the Corrective Action Decision Document/Corrective Action Plan addendum (DOE 2008a) that the Nevada Division of Environmental Protection approved (NDEP 2008)

  9. Well Completion Report for Corrective Action Unit 443 Central Nevada Test Area Nye County, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    None

    2009-12-01

    The drilling program described in this report is part of a new corrective action strategy for Corrective Action Unit (CAU) 443 at the Central Nevada Test Area (CNTA). The drilling program included drilling two boreholes, geophysical well logging, construction of two monitoring/validation (MV) wells with piezometers (MV-4 and MV-5), development of monitor wells and piezometers, recompletion of two existing wells (HTH-1 and UC-1-P-1S), removal of pumps from existing wells (MV-1, MV-2, and MV-3), redevelopment of piezometers associated with existing wells (MV-1, MV-2, and MV-3), and installation of submersible pumps. The new corrective action strategy includes initiating a new 5-year proof-of-concept monitoring period to validate the compliance boundary at CNTA (DOE 2007). The new 5-year proof-of-concept monitoring period begins upon completion of the new monitor wells and collection of samples for laboratory analysis. The new strategy is described in the Corrective Action Decision Document/Corrective Action Plan addendum (DOE 2008a) that the Nevada Division of Environmental Protection approved (NDEP 2008).

  10. Initial Efficacy Testing of an Autobiographical Memory Intervention on Advance Care Planning for Patients With Terminal Cancer.

    Science.gov (United States)

    Brohard, Cheryl

    2017-11-01

    To test the efficacy of a novel intervention to facilitate advance care planning.
. Exploratory, quasiexperimental pilot study with two independent groups.
. A large hospice located in the southwestern United States. 
. A convenience sample of 50 participants with terminal cancer enrolled in hospice.
. An autobiographical memory (ABM) intervention used the participants' experiences with cancer and end of life for the purpose of directing advance care planning.
. Two domains of advance care planning, decision making and communication, were measured in relation to 11 variables. The ABM intervention was nonthreatening, short in duration, and easily completed with participants as they recalled, without hesitation, specific personal memories of family and friends who had died and their advance care plans. The Mann-Whitney nonparametric test revealed that participants in the experimental group had a higher average rank than those in the control group for communicating the decision about antibiotics, as well as exhibited a trend toward significance for five other advance care planning variables.
. Findings showed that directive ABMs may be effective in influencing the decision making and communication of advance care planning for terminally ill patients with cancer.
. The current level of understanding about using the ABM intervention suggests that nurses can initiate an advance care planning conversation using this approach.

  11. Testing of an End-Point Control Unit Designed to Enable Precision Control of Manipulator-Coupled Spacecraft

    Science.gov (United States)

    Montgomery, Raymond C.; Ghosh, Dave; Tobbe, Patrick A.; Weathers, John M.; Manouchehri, Davoud; Lindsay, Thomas S.

    1994-01-01

    This paper presents an end-point control concept designed to enable precision telerobotic control of manipulator-coupled spacecraft. The concept employs a hardware unit (end-point control unit EPCU) that is positioned between the end-effector of the Space Shuttle Remote Manipulator System and the payload. Features of the unit are active compliance (control of the displacement between the end-effector and the payload), to allow precision control of payload motions, and inertial load relief, to prevent the transmission of loads between the end-effector and the payload. This paper presents the concept and studies the active compliance feature using a simulation and hardware. Results of the simulation show the effectiveness of the EPCU in smoothing the motion of the payload. Results are presented from initial, limited tests of a laboratory hardware unit on a robotic arm testbed at the l Space Flight Center. Tracking performance of the arm in a constant speed automated retraction and extension maneuver of a heavy payload with and without the unit active is compared for the design speed and higher speeds. Simultaneous load reduction and tracking performance are demonstrated using the EPCU.

  12. Reactor coolant system hydrostatic test and risk analysis for the first AP1000 unit

    International Nuclear Information System (INIS)

    Cao Hongjun; Yan Xiuping

    2013-01-01

    The cold hydrostatic test scheme of the primary coolant circuit, of the first AP1000 unit was described. Based on the up-stream design documents, standard specifications and design technical requirements, the select principle of test boundary was identified. The design requirements for water quality, pressure, temperature and temporary hydro-test pump were proposed. A reasonable argument for heating and pressurization rate, and cooling and depressurization rate was proposed. The possible problems and risks during the hydrostatic test were analyzed. This test scheme can provide guidance for the revisions and implementations of the follow-up test procedures. It is a good reference for hydrostatic tests of AP1000 units in the future in China. (authors)

  13. A cluster-randomized trial of provider-initiated (opt-out) HIV counseling and testing of tuberculosis patients in South Africa.

    Science.gov (United States)

    Pope, Diana S; Deluca, Andrea N; Kali, Paula; Hausler, Harry; Sheard, Carol; Hoosain, Ebrahim; Chaudhary, Mohammad A; Celentano, David D; Chaisson, Richard E

    2008-06-01

    To determine whether implementation of provider-initiated human immunodeficiency virus (HIV) counseling would increase the proportion of tuberculosis (TB) patients who received HIV counseling and testing. Cluster-randomized trial with clinic as the unit of randomization. Twenty, medium-sized primary care TB clinics in the Nelson Mandela Metropolitan Municipality, Port Elizabeth, Eastern Cape Province, South Africa. A total of 754 adults (18 years and older) newly registered as TB patients in the 20 study clinics. Implementation of provider-initiated HIV counseling and testing. Percentage of TB patients HIV counseled and tested. SECONDARY: Percentage of patients with HIV test positive, and percentage of those who received cotrimoxazole and who were referred for HIV care. : A total of 754 adults newly registered as TB patients were enrolled. In clinics randomly assigned to implement provider-initiated HIV counseling and testing, 20.7% (73/352) patients were counseled versus 7.7% (31/402) in the control clinics (P = 0.011), and 20.2% (n = 71) versus 6.5% (n = 26) underwent HIV testing (P = 0.009). Of those patients counseled, 97% in the intervention clinics accepted testing versus 79% in control clinics (P = 0.12). The proportion of patients identified as HIV infected in intervention clinics was 8.5% versus 2.5% in control clinics (P = 0.044). Fewer than 40% of patients with a positive HIV test were prescribed cotrimoxazole or referred for HIV care in either study arm. Provider-initiated HIV counseling significantly increased the proportion of adult TB patients who received HIV counseling and testing, but the magnitude of the effect was small. Additional interventions to optimize HIV testing for TB patients urgently need to be evaluated.

  14. A cluster randomized trial of provider-initiated (Opt-out) HIV counseling and testing of tuberculosis patients in South Africa

    Science.gov (United States)

    Pope, Diana S.; DeLuca, Andrea N.; Kali, Paula; Hausler, Harry; Sheard, Carol; Hoosain, Ebrahim; Chaudhary, Mohammed A.; Celentano, David D.; Chaisson, Richard E.

    2008-01-01

    Objective To determine whether implementation of provider-initiated HIV counseling would increase the proportion of tuberculosis patients that received HIV counseling and testing. Design Cluster-randomized trial with clinic as unit of randomization Setting Twenty, medium-sized primary care TB clinics in the Nelson Mandela Metropolitan Municipality, Port Elizabeth, Eastern Cape Province, South Africa Subjects A total of 754 adults (≥ 18 years) newly registered as tuberculosis patients the twenty study clinics Intervention Implementation of provider-initiated HIV counseling and testing. Main outcome measures Percentage of TB patients HIV counseled and tested. Secondary Percentage of patients HIV test positive and percentage of those that received cotrimoxazole and who were referred for HIV care. Results A total of 754 adults newly registered as tuberculosis patients were enrolled. In clinics randomly assigned to implement provider-initiated HIV counseling and testing, 20.7% (73/352) patients were counseled versus 7.7% (31/402) in the control clinics (p = 0.011), and 20.2 % (n = 71) versus 6.5% (n = 26) underwent HIV testing (p = 0.009). Of those patients counseled, 97% in the intervention clinics accepted testing versus 79% in control clinics (p =0.12). The proportion of patients identified as HIV-infected in intervention clinics was 8.5% versus 2.5% in control clinics (p=0.044). Fewer than 40% of patients with a positive HIV test were prescribed cotrimoxazole or referred for HIV care in either study arm. Conclusions Provider-initiated HIV counseling significantly increased the proportion of adult TB patients that received HIV counseling and testing, but the magnitude of the effect was small. Additional interventions to optimize HIV testing for TB patients urgently need to be evaluated. PMID:18520677

  15. Test Format and the Variation of Gender Achievement Gaps within the United States

    Science.gov (United States)

    Reardon, Sean; Fahle, Erin; Kalogrides, Demetra; Podolsky, Anne; Zarate, Rosalia

    2016-01-01

    Prior research demonstrates the existence of gender achievement gaps and the variation in the magnitude of these gaps across states. This paper characterizes the extent to which the variation of gender achievement gaps on standardized tests across the United States can be explained by differing state accountability test formats. A comprehensive…

  16. A Powerful Test of the Autoregressive Unit Root Hypothesis Based on a Tuning Parameter Free Statistic

    DEFF Research Database (Denmark)

    Nielsen, Morten Ørregaard

    This paper presents a family of simple nonparametric unit root tests indexed by one parameter, d, and containing Breitung's (2002) test as the special case d = 1. It is shown that (i) each member of the family with d > 0 is consistent, (ii) the asymptotic distribution depends on d, and thus refle...

  17. New multi-country evidence on purchasing power parity: multivariate unit root test results

    NARCIS (Netherlands)

    J.J.J. Groen (Jan)

    2000-01-01

    textabstractIn this paper a likelihood-based multivariate unit root testing framework is utilized to test whether the real exchange rates of G10 countries are non-stationary. The framework uses a likelihood ratio statistic which combines the information across all involved countries while retaining

  18. Unit-based functional IDDT testing for aging degradation monitoring in a VLIW processor

    NARCIS (Netherlands)

    Zhao, Yong; Kerkhoff, Hans G.

    2015-01-01

    In this paper, functional unit-based IDDT testing has been applied for a 90nm VLIW processor to monitor its aging degradation. This technique can provide health data for reliability evaluation as used in e.g. prognostic software for lifetime prediction. The test-program development based on the

  19. 40 CFR 63.8232 - What test methods and other procedures must I use to demonstrate initial compliance with the...

    Science.gov (United States)

    2010-07-01

    .... (e) During each test run for a by-product hydrogen stream and each test run for an end box... compliance with the emission limits? You must conduct a performance test for each by-product hydrogen stream, end box ventilation system vent, and mercury thermal recovery unit vent according to the requirements...

  20. Software Unit Testing during the Development of Digital Reactor Protection System of HTR-PM

    International Nuclear Information System (INIS)

    Guo Chao; Xiong Huasheng; Li Duo; Zhou Shuqiao; Li Jianghai

    2014-01-01

    Reactor Protection System (RPS) of High Temperature Gas-Cooled Reactor - Pebble bed Module (HTR-PM) is the first digital RPS designed and to be operated in the Nuclear Power Plant (NPP) of China, and its development process has receives a lot of concerns around the world. As a 1E-level safety system, the RPS has to be designed and developed following a series of nuclear laws and technical disciplines including software verification and validation (software V&V). Software V&V process demonstrates whether all stages during the software development are performed correctly, completely, accurately, and consistently, and the results of each stage are testable. Software testing is one of the most significant and time-consuming effort during software V&V. In this paper, we give a comprehensive introduction to the software unit testing during the development of RPS in HTR-PM. We first introduce the objective of the testing for our project in the aspects of static testing, black-box testing, and white-box testing. Then the testing techniques, including static testing and dynamic testing, are explained, and the testing strategy we employed is also introduced. We then introduce the principles of three kinds of coverage criteria we used including statement coverage, branch coverage, and the modified condition/decision coverage. As a 1E-level safety software, testing coverage needs to be up to 100% mandatorily. Then we talk the details of safety software testing during software development in HTR-PM, including the organization, methods and tools, testing stages, and testing report. The test result and experiences are shared and finally we draw a conclusion for the unit testing process. The introduction of this paper can contribute to improve the process of unit testing and software development for other digital instrumentation and control systems in NPPs. (author)

  1. Examining the Islamic stock market efficiency: Evidence from nonlinear ESTAR unit root tests

    Directory of Open Access Journals (Sweden)

    Rahmat Heru Setianto

    2015-04-01

    Full Text Available This paper empirically examines the efficient market hypothesis (EMH in the Islamic stock market namely Jakarta Islamic Index by emphasizing on the random walk behavior and nonlinearity. In the first step, we employ Brock et al. (1996 test to examine the presence of nonlinear behavior in Jakarta Islamic Index. The evidence of nonlinear behavior in the indices, motivate us to use nonlinear ESTAR unit root test procedure recently developed by Kapetanios et al. (2003 and Kruse (2011. The nonlinear unit root test procedure fail to rejects the null hypothesis of unit root for the indices, suggesting that Jakarta Islamic Index characterized by random walk process supporting the theory of efficient market hypothesis. In addition, Lumsdaine and Papel (LP test identified significant structural breaks in the index series.

  2. Initial high-power testing of the ATF [Advanced Toroidal Facility] ECH [electron cyclotron heating] system

    International Nuclear Information System (INIS)

    White, T.L.; Bigelow, T.S.; Kimrey, H.D. Jr.

    1987-01-01

    The Advanced Toroidal Facility (ATF) is a moderate aspect ratio torsatron that will utilize 53.2 GHz 200 kW Electron Cyclotron Heating (ECH) to produce nearly current-free target plasmas suitable for subsequent heating by strong neutral beam injection. The initial configuration of the ECH system from the gyrotron to ATF consists of an optical arc detector, three bellows, a waveguide mode analyzer, two TiO 2 mode absorbers, two 90 0 miter bends, two waveguide pumpouts, an insulating break, a gate valve, and miscellaneous straight waveguide sections feeding a launcher radiating in the TE 02 mode. Later, a focusing Vlasov launcher will be added to beam the ECH power to the saddle point in ATF magnetic geometry for optimum power deposition. The ECH system has several unique features; namely, the entire ECH system is evacuated, the ECH system is broadband, forward power is monitored by a newly developed waveguide mode analyzer, phase correcting miter bends will be employed, and the ECH system will be capable of operating short pulse to cw. Initial high-power tests show that the overall system efficiency is 87%. The waveguide mode analyzer shows that the gyrotron mode output consists of 13% TE 01 , 82.6% TE 02 , 2.5% TE 03 , and 1.9% TE 04 . 4 refs

  3. Initial test results of an ionization chamber shower detector for a LHC luminosity monitor

    International Nuclear Information System (INIS)

    Datte, P.; Beche, J.-F.; Haguenauer, M.; Manfredi, P.F.; Manghisoni, M.; Millaud, J.; Placidi, M.; Ratti, L.; Riot, V.; Schmickler, H.; Speziali, V.; Turner, W.

    2002-01-01

    A novel, segmented, multi-gap, pressurized gas ionization chamber is being developed for optimization of the luminosity of the LHC. The ionization chambers are to be installed in the front quadrupole and zero degree neutral particle absorbers in the high luminosity IRs and sample the energy deposited near the maxima of the hadronic/electromagnetic showers in these absorbers. The ionization chambers are instrumented with low noise, fast, pulse shaping electronics to be capable of resolving individual bunch crossings at 40 MHz. In this paper we report the initial results of our second test of this instrumentation in an SPS external proton beam. Single 300 GeV protons are used to simulate the hadronic/electromagnetic shower produced by the forward collision products from the interaction regions of the LHC. The capability of instrumentations to measure the luminosity of individual bunches in a 40 MHz bunch train is demonstrated

  4. Results of the initial test program for the Sandia Pulsed Reactor III (SPR III)

    International Nuclear Information System (INIS)

    Estes, B.F.; Reuscher, J.A.

    1976-08-01

    This document presents a detailed discussion of the reactor including the mechanical and nuclear design characteristics. Also presented are the complete results of the Initial Approach to Critical and the Zero-and-Low Power testing programs. Reactivity worth measurements are given for such parameters as control element integral worth, Safety Block integral worth, and various materials (polyethylene, copper, lead, etc) as a function of position relative to the core. Subcritical reactivity measurements made during the approach to critical generally proved to be in reasonably good agreement with design values due to the good source-fuel-detector geometry possible with a reactor of this type. Subsequent dynamic measurements for reactivity worths are shown to be in good agreement with calculated results

  5. Engineering, installation, testing, and initial operation of the DIII-D Advanced Divertor

    International Nuclear Information System (INIS)

    Andersen, P.M.; Baxi, C.B.; Reis, E.E.; Schaffer, M.J.; Smith, J.P.

    1990-09-01

    The Advanced Divertor (AD) for General Atomics tokamak, DIII-D, was installed in the summer of 1990. The AD has enabled two classes of physics experiments to be run: divertor biasing and divertor baffling. Both are new experiments for DIII-D. The AD has two principal components: (1) a continuous ring electrode; and (2) a toroidally symmetric baffle. The tokamak can be run in bias baffle or standard DIII-D divertor modes by accurate positioning of the outer divertor strike point through the use of the DIII-D control system. The paper covers design, analysis, fabrication, installation, instrumentation, testing, initial operation, and future plans for the Advanced Divertor from an engineering viewpoint. 2 refs., 5 figs

  6. Pilot-scale treatability test plan for the 200-UP-1 groundwater Operable Unit

    International Nuclear Information System (INIS)

    Wittreich, C.D.

    1994-05-01

    This document presents the treatability test plan for pilot-scale pump and treat testing at the 200-UP-1 Operable Unit. This treatability test plan has been prepared in response to an agreement between the US Department of Energy, the US Environmental Protection Agency, and the Washington State Department of Ecology, as documented in Hanford Federal Facility Agreement and Consent Order (Ecology et al. 1989a) Change Control Form M-13-93-03 (Ecology et al. 1994). The agreement also requires that, following completion of the activities described in this test plan, a 200-UP-1 Operable Unit interim remedial measure (IRM) proposed plan be developed for use in preparing an interim action record of decision (ROD). The IRM Proposed Plan will be supported by the results of the testing described in this treatability test plan, as well as by other 200-UP-1 Operable Unit activities (e.g., limited field investigation, development of a qualitative risk assessment). Once issued, the interim action ROD will specify the interim action for groundwater contamination at the 200-UP-1 Operable Unit. The approach discussed in this treatability test plan is to conduct a pilot-scale pump and treat test for the contaminant plume associated with the 200-UP-1 Operable Unit. Primary contaminants of concern are uranium and technetium-99; the secondary contaminant of concern is nitrate. The pilot-scale treatability testing presented in this test plan has as its primary purpose to assess the performance of aboveground treatment systems with respect to the ability to remove the primary contaminants in groundwater withdrawn from the contaminant plume

  7. Test Results from a Direct Drive Gas Reactor Simulator Coupled to a Brayton Power Conversion Unit

    Science.gov (United States)

    Hervol, David S.; Briggs, Maxwell H.; Owen, Albert K.; Bragg-Sitton, Shannon M.; Godfroy, Thomas J.

    2010-01-01

    Component level testing of power conversion units proposed for use in fission surface power systems has typically been done using relatively simple electric heaters for thermal input. These heaters do not adequately represent the geometry or response of proposed reactors. As testing of fission surface power systems transitions from the component level to the system level it becomes necessary to more accurately replicate these reactors using reactor simulators. The Direct Drive Gas-Brayton Power Conversion Unit test activity at the NASA Glenn Research Center integrates a reactor simulator with an existing Brayton test rig. The response of the reactor simulator to a change in Brayton shaft speed is shown as well as the response of the Brayton to an insertion of reactivity, corresponding to a drum reconfiguration. The lessons learned from these tests can be used to improve the design of future reactor simulators which can be used in system level fission surface power tests.

  8. Criteria for initiation of delamination in quasi-static punch-shear tests of a carbon-fiber composite material.

    Energy Technology Data Exchange (ETDEWEB)

    Chin, Eric Brian [Sandia National Lab. (SNL-CA), Livermore, CA (United States); English, Shawn Allen [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Briggs, Timothy [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2015-09-01

    V arious phenomenological delamination initiation criteria are analyzed in quasi - static punch - shear tests conducted on six different geometries. These six geometries are modeled and analyzed using elastic, large - deformation finite element analysis. Analysis output is post - processed to assess different delamination initiation criteria, and their applicability to each of the geometries. These criteria are compared to test results to assess whether or not they are appropriate based on what occurred in testing. Further, examinations of CT scans and ultrasonic images o f test specimens are conducted in the appendix to determine the sequence of failure in each test geometry.

  9. How does additional diagnostic testing influence the initial diagnosis in patients with cognitive complaints in a memory clinic setting?

    Science.gov (United States)

    Meijs, Anouk P; Claassen, Jurgen A H R; Rikkert, Marcel G M Olde; Schalk, Bianca W M; Meulenbroek, Olga; Kessels, Roy P C; Melis, René J F

    2015-01-01

    patients suspected of dementia frequently undergo additional diagnostic testing (e.g. brain imaging or neuropsychological assessment) after standard clinical assessment at a memory clinic. This study investigates the use of additional testing in an academic outpatient memory clinic and how it influences the initial diagnosis. the initial diagnosis after standard clinical assessment (history, laboratory tests, cognitive screening and physical and neurological examination) and the final diagnosis after additional testing of 752 memory clinic patients were collected. We specifically registered if, and what type of, additional testing was requested. additional testing was performed in 518 patients (69%), 67% of whom underwent magnetic resonance imaging, 45% had neuropsychological assessment, 14% had cerebrospinal fluid analysis and 49% had (combinations of) other tests. This led to a modification of the initial diagnosis in 17% of the patients. The frequency of change was highest in patients with an initial non-Alzheimer's disease (AD) dementia diagnosis (54%, compared with 11 and 14% in patients with AD and 'no dementia'; P testing 44% was diagnosed with AD, 9% with non-AD dementia and 47% with 'no dementia'. additional testing should especially be considered in non-AD patients. In the large group of patients with an initial AD or 'no dementia' diagnosis, additional tests have little diagnostic impact and may perhaps be used with more restraint. © The Author 2014. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Testing the system detection unit for measuring solid minerals bulk density

    Science.gov (United States)

    Voytyuk, I. N.; Kopteva, A. V.

    2017-10-01

    The paper provides a brief description of the system for measuring flux per volume of solid minerals via example of mineral coal. The paper discloses the operational principle of the detection unit. The paper provides full description of testing methodology, as well as practical implementation of the detection unit testing. This paper describes the removal of two data arrays via the channel of scattered anddirect radiation for the detection units of two generations. This paper describes Matlab software to determine the statistical characteristics of the studied objects. The mean value of pulses per cycles, and pulse counting inaccuracy relatively the mean value were determined for the calculation of the stability account of the detection units.

  11. Pilot-scale treatability test plan for the 200-BP-5 operable unit

    International Nuclear Information System (INIS)

    1994-08-01

    This document presents the treatability test plan for pilot-scale pump and treat testing at the 200-BP-5 Operable Unit. This treatability test plan has been prepared in response to an agreement between the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency (EPA), and the State of Washington Department of Ecology (Ecology), as documented in Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement, Ecology et al. 1989a) Change Control Form M-13-93-03 (Ecology et al. 1994) and a recent 200 NPL Agreement Change Control Form (Appendix A). The agreement also requires that, following completion of the activities described in this test plan, a 200-BP-5 Operable Unit Interim Remedial Measure (IRM) Proposed Plan be developed for use in preparing an Interim Action Record of Decision (ROD). The IRM Proposed Plan will be supported by the results of this treatability test plan, as well as by other 200-BP-5 Operable Unit activities (e.g., development of a qualitative risk assessment). Once issued, the Interim Action ROD will specify the interim action(s) for groundwater contamination at the 200-BP-5 Operable Unit. The treatability test approach is to conduct a pilot-scale pump and treat test for each of the two contaminant plumes associated with the 200-BP-5 Operable Unit. Primary contaminants of concern are 99 Tc and 60 Co for underwater affected by past discharges to the 216-BY Cribs, and 90 Sr, 239/240 Pu, and Cs for groundwater affected by past discharges to the 216-B-5 Reverse Well. The purpose of the pilot-scale treatability testing presented in this testplan is to provide the data basis for preparing an IRM Proposed Plan. To achieve this objective, treatability testing must: Assess the performance of groundwater pumping with respect to the ability to extract a significant amount of the primary contaminant mass present in the two contaminant plumes

  12. Test results of the signal processing and amplifier unit for the emittance measurement system

    International Nuclear Information System (INIS)

    Stawiszynski, L.; Schneider, S.

    1984-01-01

    The signal processing and amplifier unit for the emittance measurement system is the unit with which the beam current on the harp-wires and the slit is measured and converted to a digital output. Temperature effects are very critical at low currents and the purpose of the test measurements described in this report was mainly to establish the accuracy and repeatability of the measurements under the influence of temperature variations

  13. Initial development and testing of a novel foam-based pressure sensor for wearable sensing

    Directory of Open Access Journals (Sweden)

    Smyth Barry

    2005-03-01

    Full Text Available Abstract Background This paper provides an overview of initial research conducted in the development of pressure-sensitive foam and its application in wearable sensing. The foam sensor is composed of polypyrrole-coated polyurethane foam, which exhibits a piezo-resistive reaction when exposed to electrical current. The use of this polymer-coated foam is attractive for wearable sensing due to the sensor's retention of desirable mechanical properties similar to those exhibited by textile structures. Methods The development of the foam sensor is described, as well as the development of a prototype sensing garment with sensors in several areas on the torso to measure breathing, shoulder movement, neck movement, and scapula pressure. Sensor properties were characterized, and data from pilot tests was examined visually. Results The foam exhibits a positive linear conductance response to increased pressure. Torso tests show that it responds in a predictable and measurable manner to breathing, shoulder movement, neck movement, and scapula pressure. Conclusion The polypyrrole foam shows considerable promise as a sensor for medical, wearable, and ubiquitous computing applications. Further investigation of the foam's consistency of response, durability over time, and specificity of response is necessary.

  14. Forensic individual age estimation with DNA: From initial approaches to methylation tests.

    Science.gov (United States)

    Freire-Aradas, A; Phillips, C; Lareu, M V

    2017-07-01

    Individual age estimation is a key factor in forensic science analysis that can provide very useful information applicable to criminal, legal, and anthropological investigations. Forensic age inference was initially based on morphological inspection or radiography and only later began to adopt molecular approaches. However, a lack of accuracy or technical problems hampered the introduction of these DNA-based methodologies in casework analysis. A turning point occurred when the epigenetic signature of DNA methylation was observed to gradually change during an individual´s lifespan. In the last four years, the number of publications reporting DNA methylation age-correlated changes has gradually risen and the forensic community now has a range of age methylation tests applicable to forensic casework. Most forensic age predictor models have been developed based on blood DNA samples, but additional tissues are now also being explored. This review assesses the most widely adopted genes harboring methylation sites, detection technologies, statistical age-predictive analyses, and potential causes of variation in age estimates. Despite the need for further work to improve predictive accuracy and establishing a broader range of tissues for which tests can analyze the most appropriate methylation sites, several forensic age predictors have now been reported that provide consistency in their prediction accuracies (predictive error of ±4 years); this makes them compelling tools with the potential to contribute key information to help guide criminal investigations. Copyright © 2017 Central Police University.

  15. Using Controlled Landslide Initiation Experiments to Test Limit-Equilibrium Analyses of Slope Stability

    Science.gov (United States)

    Reid, M. E.; Iverson, R. M.; Brien, D. L.; Iverson, N. R.; Lahusen, R. G.; Logan, M.

    2004-12-01

    Most studies of landslide initiation employ limit equilibrium analyses of slope stability. Owing to a lack of detailed data, however, few studies have tested limit-equilibrium predictions against physical measurements of slope failure. We have conducted a series of field-scale, highly controlled landslide initiation experiments at the USGS debris-flow flume in Oregon; these experiments provide exceptional data to test limit equilibrium methods. In each of seven experiments, we attempted to induce failure in a 0.65m thick, 2m wide, 6m3 prism of loamy sand placed behind a retaining wall in the 31° sloping flume. We systematically investigated triggering of sliding by groundwater injection, by prolonged moderate-intensity sprinkling, and by bursts of high intensity sprinkling. We also used vibratory compaction to control soil porosity and thereby investigate differences in failure behavior of dense and loose soils. About 50 sensors were monitored at 20 Hz during the experiments, including nests of tiltmeters buried at 7 cm spacing to define subsurface failure geometry, and nests of tensiometers and pore-pressure sensors to define evolving pore-pressure fields. In addition, we performed ancillary laboratory tests to measure soil porosity, shear strength, hydraulic conductivity, and compressibility. In loose soils (porosity of 0.52 to 0.55), abrupt failure typically occurred along the flume bed after substantial soil deformation. In denser soils (porosity of 0.41 to 0.44), gradual failure occurred within the soil prism. All failure surfaces had a maximum length to depth ratio of about 7. In even denser soil (porosity of 0.39), we could not induce failure by sprinkling. The internal friction angle of the soils varied from 28° to 40° with decreasing porosity. We analyzed stability at failure, given the observed pore-pressure conditions just prior to large movement, using a 1-D infinite-slope method and a more complete 2-D Janbu method. Each method provides a static

  16. Construction and start-up tests for Unit No. 5 of Fukushima Daiichi Nuclear Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, T; Sunami, Y; Ishii, N; Yokojima, T [Toshiba Corp., Kawasaki, Kanagawa (Japan)

    1978-12-01

    This unit, with an output capacity of 874 MWe, was completed by Toshiba last April on the basis of the actual operation records of the units previously completed and the experience in construction. Since its completion it has continued very excellent operation, with no emergency stop. This article is a description of the Unit 5, about: (1) the design and major points of improvement; (2) the construction work and cleaning of the plant; and (3) the operation tests, the use of the first automatic fuel exchanger, and the plant management system including the rust-preventive measures for two years since the oil-crisis.

  17. Empirical investigation of purchasing power parity for Turkey: Evidence from recent nonlinear unit root tests

    Directory of Open Access Journals (Sweden)

    Dilem Yıldırım

    2017-06-01

    Full Text Available This study explores the empirical validity of the purchasing power parity (PPP hypothesis between Turkey and its four major trading partners, the European Union, Russia, China and the US. Accounting for the nonlinear nature of real exchange rates, we employ a battery of recently developed nonlinear unit root tests. Our empirical results reveal that nonlinear unit root tests deliver stronger evidence in favour of the PPP hypothesis when compared to the conventional unit root tests only if nonlinearities in real exchange rates are correctly specified. Furthermore, it emerges from our findings that the real exchange rates of the countries having a free trade agreement are more likely to behave as linear stationary processes.

  18. Fat Tail Model for Simulating Test Systems in Multiperiod Unit Commitment

    Directory of Open Access Journals (Sweden)

    J. A. Marmolejo

    2015-01-01

    Full Text Available This paper describes the use of Chambers-Mallows-Stuck method for simulating stable random variables in the generation of test systems for economic analysis in power systems. A study that focused on generating test electrical systems through fat tail model for unit commitment problem in electrical power systems is presented. Usually, the instances of test systems in Unit Commitment are generated using normal distribution, but in this work, simulations data are based on a new method. For simulating, we used three original systems to obtain the demand behavior and thermal production costs. The estimation of stable parameters for the simulation of stable random variables was based on three generally accepted methods: (a regression, (b quantiles, and (c maximum likelihood, choosing one that has the best fit of the tails of the distribution. Numerical results illustrate the applicability of the proposed method by solving several unit commitment problems.

  19. Long-term persistence of quality improvements for an intensive care unit communication initiative using the VALUE strategy.

    Science.gov (United States)

    Wysham, Nicholas G; Mularski, Richard A; Schmidt, David M; Nord, Shirley C; Louis, Deborah L; Shuster, Elizabeth; Curtis, J Randall; Mosen, David M

    2014-06-01

    Communication in the intensive care unit (ICU) is an important component of quality ICU care. In this report, we evaluate the long-term effects of a quality improvement (QI) initiative, based on the VALUE communication strategy, designed to improve communication with family members of critically ill patients. We implemented a multifaceted intervention to improve communication in the ICU and measured processes of care. Quality improvement components included posted VALUE placards, templated progress note inclusive of communication documentation, and a daily rounding checklist prompt. We evaluated care for all patients cared for by the intensivists during three separate 3 week periods, pre, post, and 3 years following the initial intervention. Care delivery was assessed in 38 patients and their families in the pre-intervention sample, 27 in the post-intervention period, and 41 in follow-up. Process measures of communication showed improvement across the evaluation periods, for example, daily updates increased from pre 62% to post 76% to current 84% of opportunities. Our evaluation of this quality improvement project suggests persistence and continued improvements in the delivery of measured aspects of ICU family communication. Maintenance with point-of-care-tools may account for some of the persistence and continued improvements. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Decontamination and decommissioning of the initial engine test facility and the IET two-inch hot-waste line

    International Nuclear Information System (INIS)

    Stoll, F.E.

    1987-04-01

    The Initial Engine Test Decommissioning Project is described in this report. The Initial Engine Test facility was constructed and operated at the National Reactor Testing Station, now known as the Idaho National Engineering Laboratory, to support the Aircraft Nuclear Propulsion Program and the Systems for Nuclear Auxiliary Power Transient test program, circa 1950 through 1960s. Due to the severe nature of these nuclear test programs, a significant amount of radioactive contamination was deposited in various portions of the Initial Engine Test Facility. Characterizations, decision analyses, and plans for decontamination and decommissioning were prepared from 1982 through 1985. Decontamination and decommissioning activities were performed in such a way that no radiological health or safety hazard to the public or to personnel at the Idaho National Engineering Laboratory remains. These decontamination and decommissioning activities began in 1985 and were completed in 1987. 13 figs

  1. Design of a Facility to Test the Advanced Stirling Radioisotope Generator Engineering Unit

    Science.gov (United States)

    Lewandowski, Edward J.; Schreiber, Jeffrey G.; Oriti, Salvatore M.; Meer, David W.; Brace, Michael H.; Dugala, Gina

    2009-01-01

    The Advanced Stirling Radioisotope Generator (ASRG) is being considered to power deep space missions. An engineering unit, the ASRG-EU, was designed and fabricated by Lockheed Martin under contract to the Department of Energy. This unit is currently on an extended operation test at NASA Glenn Research Center to generate performance data and validate the life and reliability predictions for the generator and the Stirling convertors. A special test facility was designed and built for testing the ASRG-EU. Details of the test facility design are discussed. The facility can operate the convertors under AC bus control or with the ASRG-EU controller. It can regulate input thermal power in either a fixed temperature or fixed power mode. An enclosure circulates cooled air around the ASRG-EU to remove heat rejected from the ASRG-EU by convection. A custom monitoring and data acquisition system supports the test. Various safety features, which allow 2417 unattended operation, are discussed.

  2. Soil washing physical separations test procedure - 300-FF-1 operable unit

    Energy Technology Data Exchange (ETDEWEB)

    Belden, R.D.

    1993-10-08

    This procedure provides the operations approach, a field sampling plan, and laboratory procedures for a soil washing test to be conducted by Alternative Remedial Technologies, Inc. (ART) in the 300-FF-1 area at the Hanford site. The {open_quotes}Quality Assurance Project Plan for the Soil Washing Physical Separations Test, 300-FF-1 Operable Unit,{close_quotes} Hanford, Washington, Alternative Remedial Technologies, Inc., February 1994 (QAPP) is provided in a separate document that presents the procedural and organizational guidelines for this test. This document describes specifications, responsibilities, and general procedures to be followed to conduct physical separation soil treatability tests in the North Process Pond of the 300-FF-1 Operable Unit (OU) at the Hanford Site. These procedures are based on the {open_quotes}300-FF-1 Physical Separations CERCLA Treatability Test Plan, DOE/RL 92-2l,{close_quotes} (DOE-RL 1993).

  3. Soil washing physical separations test procedure - 300-FF-1 operable unit

    International Nuclear Information System (INIS)

    Belden, R.D.

    1993-01-01

    This procedure provides the operations approach, a field sampling plan, and laboratory procedures for a soil washing test to be conducted by Alternative Remedial Technologies, Inc. (ART) in the 300-FF-1 area at the Hanford site. The open-quotes Quality Assurance Project Plan for the Soil Washing Physical Separations Test, 300-FF-1 Operable Unit,close quotes Hanford, Washington, Alternative Remedial Technologies, Inc., February 1994 (QAPP) is provided in a separate document that presents the procedural and organizational guidelines for this test. This document describes specifications, responsibilities, and general procedures to be followed to conduct physical separation soil treatability tests in the North Process Pond of the 300-FF-1 Operable Unit (OU) at the Hanford Site. These procedures are based on the open-quotes 300-FF-1 Physical Separations CERCLA Treatability Test Plan, DOE/RL 92-2l,close quotes (DOE-RL 1993)

  4. Initial testing of a pixelated silicon detector prototype in proton therapy.

    Science.gov (United States)

    Wroe, Andrew J; McAuley, Grant; Teran, Anthony V; Wong, Jeannie; Petasecca, Marco; Lerch, Michael; Slater, James M; Rozenfeld, Anatoly B

    2017-09-01

    As technology continues to develop, external beam radiation therapy is being employed, with increased conformity, to treat smaller targets. As this occurs, the dosimetry methods and tools employed to quantify these fields for treatment also have to evolve to provide increased spatial resolution. The team at the University of Wollongong has developed a pixelated silicon detector prototype known as the dose magnifying glass (DMG) for real-time small-field metrology. This device has been tested in photon fields and IMRT. The purpose of this work was to conduct the initial performance tests with proton radiation, using beam energies and modulations typically associated with proton radiosurgery. Depth dose and lateral beam profiles were measured and compared with those collected using a PTW parallel-plate ionization chamber, a PTW proton-specific dosimetry diode, EBT3 Gafchromic film, and Monte Carlo simulations. Measurements of the depth dose profile yielded good agreement when compared with Monte Carlo, diode and ionization chamber. Bragg peak location was measured accurately by the DMG by scanning along the depth dose profile, and the relative response of the DMG at the center of modulation was within 2.5% of that for the PTW dosimetry diode for all energy and modulation combinations tested. Real-time beam profile measurements of a 5 mm 127 MeV proton beam also yielded FWHM and FW90 within ±1 channel (0.1 mm) of the Monte Carlo and EBT3 film data across all depths tested. The DMG tested here proved to be a useful device at measuring depth dose profiles in proton therapy with a stable response across the entire proton spread-out Bragg peak. In addition, the linear array of small sensitive volumes allowed for accurate point and high spatial resolution one-dimensional profile measurements of small radiation fields in real time to be completed with minimal impact from partial volume averaging. © 2017 The Authors. Journal of Applied Clinical Medical Physics published

  5. Acute diverticulitis of the sigmoid colon: value of ultrasound as an initial diagnostic test

    International Nuclear Information System (INIS)

    Garcia-Aguayo, F. J.; Gil, P. M.

    2002-01-01

    To assess the value of ultrasound as an initial diagnostic method in cases of acute diverticulitis. Ultrasound was carried out in 76 patients with a clinical diagnosis of acute sigmoid diverticulitis. The final diagnosis was based on the clinical course in every case, as well as on computed tomography (CT; n=46), histopathological examination (n=10), colonoscopy (n=4) and barium enema (n=2). The diagnostic criteria established for ultrasound was a thickening of the sigmoid colon wall of >4 mm and the presence of a least one of the following features: diverticular, phlegmon or abscess. The CT diagnosis was based on two indispensable findings: thickening of the sigmoid colon of>4 mm and inflammation of pericolonic fat. The final diagnosis was acute diverticulitis in 52 patients, some other disease in 18 and undetermined in 6. The sensitivities of ultrasound and CT were 81% and 94%, respectively, and their specificities were 79% and 83%, respectively. Of the 10 false negatives on ultrasound, seven corresponded to cases of simple diverticulitis and three to cases of complicated diverticulitis (two in patients with abscess and one in a patient with pneumoperitoneum). CT provided the correct diagnosis in eight of these cases, and resulted in false negatives in two cases of mild diverticulitis. Ultrasound is a valid test in the initial diagnosis of acute diverticulitis of the sigmoid colon. CT should be performed when ultrasound fails to provide a diagnosis or in cases of negative results when there is a strong clinical suspicion of diverticulitis, as well as when the possibility of complicated diverticulitis exists. (Author) 14 refs

  6. Development of field simulator to test and qualify the gyrotron local control unit for ITER-India Gyrotron Test Facility

    International Nuclear Information System (INIS)

    Shah, Ronak; Mandge, Deepak; Rathod, Vipal; Parmar, Rajvi; Dilip, E. Sharan; Yadav, Amit; Sharma, Anjali; Rao, S.L.

    2017-01-01

    High power RF sources such as a Gyrotron system are operated at required output parameter by using various auxiliary power supplies, High voltage power supplies, auxiliary services and a dedicated Local Control Unit (LCU). These sub-systems must be operated in synchronous and safe way to control the gyrotron output parameters. The LCU performs remote, synchronous and safe operation of the all the gyrotron sub-systems. Broadly the LCU functions are operational control, data acquisition, protection and safety of the gyrotron system. At ITER-India gyrotron Test Facility (IIGTF) a local control unit (LCU) is being developed to operate the complete gyrotron system. This paper presents the design, development and various features of the field simulator. It also discuss LCU functionality test cases and results obtained using field simulator

  7. Testing the Birth Unit Design Spatial Evaluation Tool (BUDSET) in Australia: a pilot study.

    Science.gov (United States)

    Foureur, Maralyn J; Leap, Nicky; Davis, Deborah L; Forbes, Ian F; Homer, Caroline E S

    2011-01-01

    To pilot test the Birth Unit Design Spatial Evaluation Tool (BUDSET) in an Australian maternity care setting to determine whether such an instrument can measure the optimality of different birth settings. Optimally designed spaces to give birth are likely to influence a woman's ability to experience physiologically normal labor and birth. This is important in the current industrialized environment, where increased caesarean section rates are causing concerns. The measurement of an optimal birth space is currently impossible, because there are limited tools available. A quantitative study was undertaken to pilot test the discriminant ability of the BUDSET in eight maternity units in New South Wales, Australia. Five auditors trained in the use of the BUDSET assessed the birth units using the BUDSET, which is based on 18 design principles and is divided into four domains (Fear Cascade, Facility, Aesthetics, and Support) with three to eight assessable items in each. Data were independently collected in eight birth units. Values for each of the domains were aggregated to provide an overall Optimality Score for each birth unit. A range of Optimality Scores was derived for each of the birth units (from 51 to 77 out of a possible 100 points). The BUDSET identified units with low-scoring domains. Essentially these were older units and conventional labor ward settings. The BUDSET provides a way to assess the optimality of birth units and determine which domain areas may need improvement. There is potential for improvements to existing birth spaces, and considerable improvement can be made with simple low-cost modifications. Further research is needed to validate the tool.

  8. Test plan for the field evaluation and demonstration of the Contamination Control Unit

    International Nuclear Information System (INIS)

    Winberg, M.R.; Thompson, D.N.

    1993-06-01

    This report describes test details of a full demonstration of the Contamination Control Unit (CCU). The CCU is a mobile trailer capable of employing the use of soil fixatives, dust suppression agents, misting, and vacuum systems. These systems can perform a large number of contamination control functions to support the Office of Waste Technology Development (OTD) Buried Waste Integrated Demonstration (BWID) projects, transuranic (TRU) waste retrieval operations, and emergency response for hazardous and radioactive materials incidents. The demonstration will include both performance testing at the North Holmes Laboratory Facility (NHLF) and field testing in conjunction with the Remote Excavation System Demonstration at the Cold Test Pit. The NHLF will test operational parameters using water only, and the field demonstration at the Cold Test Pit involves full scale operation of vacuum, fixant, misting, and dust suppression systems. Test objectives, detailed experimental procedures, and data quality objectives necessary to perform the field demonstration are included in this test plan

  9. Bringing testing to the people - benefits of mobile unit HIV/syphilis testing in Lima, Peru, 2007-2009.

    Science.gov (United States)

    Lipsitz, Mindy C; Segura, Eddy R; Castro, José Luis; Smith, Edward; Medrano, Carlos; Clark, Jesse L; Lake, Jordan E; Cabello, Robinson

    2014-04-01

    Mobile unit (MU) HIV testing is an alternative method of providing healthcare access. We compared demographic and behavioural characteristics, HIV testing history and HIV prevalence between participants seeking testing at a MU vs. fixed clinic (FC) in Lima, Peru. Our analysis included men and transgender women (TW) in Lima aged ≥ 18 years old seeking HIV testing at their first visit to a community-based MU or FC from October 2007 to November 2009. HIV testing history, HIV serostatus and behavioural characteristics were analysed. A large percentage of MU attendees self-identified as transgender (13%) or heterosexual (41%). MU attendees were more likely to engage in transactional sex (24% MU vs. 10% FC, p < 0.001), use alcohol/drugs during their last sexual encounter (24% MU vs. 20% FC, p < 0.01) and/or be a first-time HIV tester (48% MU vs. 41% FC, p < 0.001). MU HIV prevalence was 9% overall and 5% among first-time testers (49% in TW and 11% in men who have sex with men [MSM] first-time testers). MU testing reached large numbers of at-risk (MSM/TW) populations engaged in unsafe sexual behaviours, making MU outreach a worthy complement to FC testing. Investigation into whether MU attendees would otherwise access HIV testing is warranted to determine the impact of MU testing.

  10. Corrective Action Investigation Plan for Corrective Action Unit 543: Liquid Disposal Units, Nevada Test Site, Nevada: Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office

    2004-05-03

    The general purpose of this Corrective Action Investigation Plan is to ensure that adequate data are collected to provide sufficient and reliable information to identify, evaluate, and select technically viable corrective action alternatives (CAAs) for Corrective Action Unit (CAU) 543: Liquid Disposal Units, Nevada Test Site (NTS), Nevada. Located in Areas 6 and 15 on the NTS, CAU 543 is comprised of a total of seven corrective action sites (CASs), one in Area 6 and six in Area 15. The CAS in Area 6 consists of a Decontamination Facility and its components which are associated with decontamination of equipment, vehicles, and materials related to nuclear testing. The six CASs in Area 15 are located at the U.S. Environmental Protection Agency Farm and are related to waste disposal activities at the farm. Sources of possible contamination at Area 6 include potentially contaminated process waste effluent discharged through a process waste system, a sanitary waste stream generated within buildings of the Decon Facility, and radiologically contaminated materials stored within a portion of the facility yard. At Area 15, sources of potential contamination are associated with the dairy operations and the animal tests and experiments involving radionuclide uptake. Identified contaminants of potential concern include volatile organic compounds, semivolatile organic compounds, petroleum hydrocarbons, pesticides, herbicides, polychlorinated biphenyls, metals, and radionuclides. Three corrective action closure alternatives - No Further Action, Close in Place, or Clean Closure - will be recommended for CAU 543 based on an evaluation of all the data quality objective-related data. Field work will be conducted following approval of the plan. The results of the field investigation will support a defensible evaluation of CAAs that will be presented in the Corrective Action Decision Document.

  11. 40 CFR 63.1571 - How and when do I conduct a performance test or other initial compliance demonstration?

    Science.gov (United States)

    2010-07-01

    ..., according to § 63.7(a)(2)(ix). (b) What are the general requirements for performance test and performance... according to the provisions in § 63.7(a)(2). If you are required to do a performance evaluation or test for a semi-regenerative catalytic reforming unit catalyst regenerator vent, you may do them at the first...

  12. X-ray scatter correction method for dedicated breast computed tomography: improvements and initial patient testing

    International Nuclear Information System (INIS)

    Ramamurthy, Senthil; D’Orsi, Carl J; Sechopoulos, Ioannis

    2016-01-01

    A previously proposed x-ray scatter correction method for dedicated breast computed tomography was further developed and implemented so as to allow for initial patient testing. The method involves the acquisition of a complete second set of breast CT projections covering 360° with a perforated tungsten plate in the path of the x-ray beam. To make patient testing feasible, a wirelessly controlled electronic positioner for the tungsten plate was designed and added to a breast CT system. Other improvements to the algorithm were implemented, including automated exclusion of non-valid primary estimate points and the use of a different approximation method to estimate the full scatter signal. To evaluate the effectiveness of the algorithm, evaluation of the resulting image quality was performed with a breast phantom and with nine patient images. The improvements in the algorithm resulted in the avoidance of introduction of artifacts, especially at the object borders, which was an issue in the previous implementation in some cases. Both contrast, in terms of signal difference and signal difference-to-noise ratio were improved with the proposed method, as opposed to with the correction algorithm incorporated in the system, which does not recover contrast. Patient image evaluation also showed enhanced contrast, better cupping correction, and more consistent voxel values for the different tissues. The algorithm also reduces artifacts present in reconstructions of non-regularly shaped breasts. With the implemented hardware and software improvements, the proposed method can be reliably used during patient breast CT imaging, resulting in improvement of image quality, no introduction of artifacts, and in some cases reduction of artifacts already present. The impact of the algorithm on actual clinical performance for detection, diagnosis and other clinical tasks in breast imaging remains to be evaluated. (paper)

  13. Health care resource utilization before and after perampanel initiation among patients with epilepsy in the United States.

    Science.gov (United States)

    Faught, Edward; Laliberté, François; Wang, Zhixiao; Barghout, Victoria; Haider, Batool; Lejeune, Dominique; Germain, Guillaume; Choi, Jiyoon; Wagh, Aneesha; Duh, Mei Sheng

    2017-10-01

    The purpose of this study was to evaluate changes in health care resource utilization following the initiation of perampanel for the treatment of epilepsy in the United States. Health care claims from Symphony Health's Integrated Dataverse database between December 2012 and November 2015 were analyzed. Patients newly initiated on perampanel, having ≥1 epilepsy (International Classification of Diseases, Ninth Revision, Clinical Modification [ICD-9-CM] code 345.xx, ICD-10-CM code G40.xxx) or nonfebrile convulsion (ICD-9-CM code 780.39, ICD-10-CM code R56.9) diagnosis, and having ≥6 months of baseline and observation periods were included. Patients <12 years old at perampanel initiation were excluded. Of the 2,508 perampanel patients included in the study, the mean [median] (±standard deviation [SD]) age was 35.8 [34] (±16.0) years and 56.2% were female. The mean [median] (±SD) observation duration was 459.8 [462] (±146.3) days in the postperampanel period. The postperampanel period was associated with significantly lower rates of all health care resource utilization outcomes than the pre-period. For the post- versus pre-period, perampanel users had 42.3 versus 53.8 overall hospitalizations per 100 person-years (rate ratio [RR] = 0.80, p < 0.001) and 1,240.2 versus 1,343.8 outpatient visits per 100 person-years (RR = 0.91, p < 0.001). Epilepsy-related hospitalizations and outpatient visits were 25.2 versus 33.6 per 100 person-years (RR = 0.76, p < 0.001) and 327.0 versus 389.0 per 100 person-years (RR = 0.84, p < 0.001), respectively. Additionally, a significantly lower rate of status epilepticus in the post-period (1.8 events per 100 person-years) was observed compared to the pre-period (4.4 events per 100 person-years; RR = 0.43, p < 0.001). The monthly time trend of hospitalizations showed an increasing trend leading up to the initiation of perampanel, after which the hospitalizations decreased steadily. Use of perampanel for the treatment of epilepsy was

  14. Initial results of tests of depth markers as a surface diagnostic for fusion devices

    Directory of Open Access Journals (Sweden)

    L.A. Kesler

    2017-08-01

    Full Text Available The Accelerator-Based In Situ Materials Surveillance (AIMS diagnostic was developed to perform in situ ion beam analysis (IBA on Alcator C-Mod in August 2012 to study divertor surfaces between shots. These results were limited to studying low-Z surface properties, because the Coulomb barrier precludes nuclear reactions between high-Z elements and the ∼1 MeV AIMS deuteron beam. In order to measure the high-Z erosion, a technique using deuteron-induced gamma emission and a low-Z depth marker is being developed. To determine the depth of the marker while eliminating some uncertainty due to beam and detector parameters, the energy dependence of the ratio of two gamma yields produced from the same depth marker will be used to determine the ion beam energy loss in the surface, and thus the thickness of the high-Z surface. This paper presents the results of initial trials of using an implanted depth marker layer with a deuteron beam and the method of ratios. First tests of a lithium depth marker proved unsuccessful due to the production of conflicting gamma peaks, among other issues. However, successful trials with a boron depth marker show that it is possible to measure the depth of the marker layer with the method of gamma yield ratios.

  15. Design and initial tests of beam current monitoring systems for the APS transport lines

    International Nuclear Information System (INIS)

    Wang, Xucheng.

    1992-01-01

    The non-intercepting beam current monitoring systems suitable for a wide, range of beam parameters have been developed for the Advanced Photon Source (APS) low energy transport lines and high energy transport line. The positron or electron beam pulse in the transport lines wig have peak beam currents ranging from 8 mA to 29 A with pulse widths varying from 120 ps to 30 ns and pulse repetition rates from 2 Hz to 60 Hz. The peak beam current or total beam charge is measured with the fast or integrating current transformer, respectively, manufactured by Bergoz. In-house high speed beam signal processing electronics provide a DC level output proportional to the peak current or total charge for the digitizer input. The prototype systems were tested on the linacs which have beam pulse structures similar to that of the APS transport lines. This paper describes the design of beam signal processing electronics and grounding and shielding methods for current transformers. The results of the initial operations are presented. A short introduction on the preliminary design of current monitoring systems for the APS rings is also included

  16. Implementation and Initial Testing of Advanced Processing and Analysis Algorithms for Correlated Neutron Counting

    Energy Technology Data Exchange (ETDEWEB)

    Santi, Peter Angelo [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Cutler, Theresa Elizabeth [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Favalli, Andrea [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Koehler, Katrina Elizabeth [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Henzl, Vladimir [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Henzlova, Daniela [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Parker, Robert Francis [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Croft, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-12-01

    In order to improve the accuracy and capabilities of neutron multiplicity counting, additional quantifiable information is needed in order to address the assumptions that are present in the point model. Extracting and utilizing higher order moments (Quads and Pents) from the neutron pulse train represents the most direct way of extracting additional information from the measurement data to allow for an improved determination of the physical properties of the item of interest. The extraction of higher order moments from a neutron pulse train required the development of advanced dead time correction algorithms which could correct for dead time effects in all of the measurement moments in a self-consistent manner. In addition, advanced analysis algorithms have been developed to address specific assumptions that are made within the current analysis model, namely that all neutrons are created at a single point within the item of interest, and that all neutrons that are produced within an item are created with the same energy distribution. This report will discuss the current status of implementation and initial testing of the advanced dead time correction and analysis algorithms that have been developed in an attempt to utilize higher order moments to improve the capabilities of correlated neutron measurement techniques.

  17. Operation of the tokamak fusion test reactor tritium systems during initial tritium experiments

    International Nuclear Information System (INIS)

    Anderson, J.L.; Gentile, C.; Kalish, M.; Kamperschroer, J.; Kozub, T.; LaMarche, P.; Murray, H.; Nagy, A.; Raftopoulos, S.; Rossmassler, R.; Sissingh, R.; Swanson, J.; Tulipano, F.; Viola, M.; Voorhees, D.; Walters, R.T.

    1995-01-01

    The high power D-T experiments on the tokamak fusion test reactor (TFTR) at the Princeton Plasma Physics Laboratory commenced in November 1993. During initial operation of the tritium systems a number of start-up problems surfaced and had to be corrected. These were corrected through a series of system modifications and upgrades and by repair of failed or inadequate components. Even as these operational concerns were being addressed, the tritium systems continued to support D-T operations on the tokamak. During the first six months of D-T operations more than 107kCi of tritium were processed successfully by the tritium systems. D-T experiments conducted at TFTR during this period provided significant new data. Fusion power in excess of 9MW was achieved in May 1994. This paper describes some of the early start-up issues, and reports on the operation of the tritium system and the tritium tracking and accounting system during the early phase of TFTR D-T experiments. (orig.)

  18. Pisgah Lava Cave Communication Test: Science Case Study for the Networked Constellations Initiative

    Science.gov (United States)

    Belov, K.; Ellison, D.; Fraeman, A.

    2017-01-01

    As part of the science case study for the Networked Constellations initiative, a team of JPL scientists explore the possibility of a mission to study the lava caves on Mars. Natural caves on Mars and the Moon present a unique opportunity to learn about the planetary geology and to provide a shelter for human explorers. Due to power and communication challenges, a network of assets has significant advantages over a single asset sent inside a cave. However, communication between the assets and the data downlink present significant difficulties due to the presence of rough walls, boulders, and other obstacles with unknown dielectric constant inside a typical cave, disturbing the propagation of the radio waves. A detailed study is needed to establish the limitations of the current communication technologies and to develop requirements for the new communication technology applicable to the cave environment. On May 4 of 2017, Konstantin Belov, Doug Ellison, and Abby Fraeman visited a lava cave in Pisgah, CA. The purpose of the visit was to build a 3D map of the cave, which could be used to create a model of radio wave propagation, and to conduct a series of communication tests using off-the-shelf equipment to verify the in-cave communication challenges. This experiment should be considered as a simple 'proof of concept' and is the subject of this report.

  19. Start-up tests of Kashiwazakikariwa Nuclear Power Station Unit No.2 and No.5

    International Nuclear Information System (INIS)

    Fueki, Kensuke; Aoki, Shiro; Tanaka, Yasuhisa; Yahagi, Kimitoshi

    1991-01-01

    The Kashiwazakikariwa Nuclear Power Station Units No.5 and No.2 started commercial operation on April 10 and September 28 of 1990 respectively. As the result of the application of the First and Second LWR Improvement and Standardization Program, the plants were designed aiming at improvement of reliability, operation, and maintenance while maintaining safety. Construction of the plants took 6.5 to 7 years for completion, during which period the last 10 months were spent for the start up tests program. Start up tests were carried out under deliberate management to assure that the plants can operate safely and steadily at the prescribed operating points, and the schedules and tests item modifications adopted in Unit No.2 and No.5 were verified under the start up tests program. (author)

  20. Testing of the Advanced Stirling Radioisotope Generator Engineering Unit at NASA Glenn Research Center

    Science.gov (United States)

    Lewandowski, Edward J.

    2013-01-01

    The Advanced Stirling Radioisotope Generator (ASRG) is a high-efficiency generator being developed for potential use on a Discovery 12 space mission. Lockheed Martin designed and fabricated the ASRG Engineering Unit (EU) under contract to the Department of Energy. This unit was delivered to NASA Glenn Research Center in 2008 and has been undergoing extended operation testing to generate long-term performance data for an integrated system. It has also been used for tests to characterize generator operation while varying control parameters and system inputs, both when controlled with an alternating current (AC) bus and with a digital controller. The ASRG EU currently has over 27,000 hours of operation. This paper summarizes all of the tests that have been conducted on the ASRG EU over the past 3 years and provides an overview of the test results and what was learned.

  1. The software testing of PPS for shin Ulchin nuclear power plant units 1 and 2

    International Nuclear Information System (INIS)

    Kang, Dong Pa; Park, Cheol Lak; Cho, Chang Hui; Sohn, Se Do; Baek, Seung Min

    2012-01-01

    The testing of software (S/W) is the process of analyzing a software item to detect the differences between existing and required conditions to evaluate the features of the software items. This paper introduces the S/W testing of Plant Protection System (PPS), as a safety system which actuate Reactor Trip (RT) and Engineered Safety Features (ESF) for Shin Ulchin Nuclear Power Plant Units 1 and 2 (SUN 1 and 2)

  2. Purchasing power parity in OECD countries: nonlinear unit root tests revisited

    OpenAIRE

    Juan Carlos Cuestas; Paulo José Regis

    2010-01-01

    The aim of this paper is to provide additional evidence on the purchasing power parity empirical fulfillment in a pool of OECD countries. We apply the Harvey et al. (2008) linearity test and the Kruse (2010) nonlinear unit root test. The results point to the fact that the purchasing power parity theory holds in a greater number of countries than has been reported in previous studies.

  3. The validity of PPP: evidence from Lagrange multiplier unit root tests for ASEAN countries

    OpenAIRE

    Alper ASLAN

    2010-01-01

    The univariate and panel Lagrange Multiplier (LM) unit root tests with one and two structural breaks proposed by Lee and Strazicich (2003, 2004) which are considerably more powerful than traditional tests are employed to investigate whether the purchasing power parity (PPP) theory holds true for ASEAN countries by using both black market and official exchange rates. We find strong evidence in favour of long-run PPP for six ASEAN countries namely, Indonesia, Malaysia, Myanmar, Philippines, Sin...

  4. Development and Evaluation of a Student-Initiated Test Preparation Program for the USMLE Step 1 Examination.

    Science.gov (United States)

    Schwartz, Lindsay F; Lineberry, Matthew; Park, Yoon Soo; Kamin, Carol S; Hyderi, Abbas A

    2018-01-01

    Studies have documented performance on the United States Medical Licensing Examination® (USMLE) Step 1 exam as an important factor that residency program directors consider when deciding which applicants to interview and rank. Therefore, success on this exam, though only one aspect of applicant evaluation, is important in determining future career prospects for medical students. Unfortunately, mean test scores at the University of Illinois College of Medicine at Chicago (UIC) have historically been below the national average. This retrospective and quasi-experimental mixed-methods study describes the development, evaluation, and effects of a student-initiated USMLE Step 1 preparatory program at UIC. The program provided second year students with First Aid for the USMLE Step 1 at the beginning of the academic year, as well as a six month subscription to the USMLE World question bank midyear. In addition, optional peer review sessions covering basic sciences and organ systems were taught by high-performing upperclassmen. The goals of the program were to raise mean USMLE Step 1 exam scores and increase the percentage of students passing the exam on their first time. The program premiered during the 2012-13 academic year. Data from this cohort as well as four others (N = 830; 2010-2014 examinees) were gathered. Performances between preintervention (2010-12 examinees) and postintervention (2013-14 examinees) cohorts of students were compared. Focus groups and interviews with staff and students were conducted, recorded, and analyzed to investigate the impact that the program had on student interactions and perceptions of the learning environment. There was a significant difference in exam performance pre- versus postintervention, with average USMLE Step 1 scores improving by 8.82 points following the implementation of the student-initiated program, t(5.61) = 828, p Step 1 (odds ratio = 3.08, SE = 1.07, p < .01). Students and staff commented on the sense of community and

  5. Field Tests of Wind Turbine Unit with Tandem Wind Rotors and Double Rotational Armatures

    Science.gov (United States)

    Galal, Ahmed Mohamed; Kanemoto, Toshiaki

    This paper discusses the field tests of the wind turbine unit, in which the front and the rear wind rotors drive the inner and the outer armatures of the synchronous generator. The wind rotors were designed conveniently by the traditional procedure for the single wind rotor, where the diameters of the front and the rear wind rotors are 2 m and 1.33 m. The tests were done on a pick-up type truck driven straightly at constant speed. The rotational torque of the unit is directly proportional to the induced electric current irrespective of the rotational speeds of the wind rotors, while the induced voltage is proportional to the relative rotational speed. The performance of the unit is significantly affected not only by the wind velocity, but also by the blade setting angles of both wind rotors and the applied load especially at lower wind velocity.

  6. Analogue particle identifier and test unit for automatic measuring of errors

    International Nuclear Information System (INIS)

    Boden, A.; Lauch, J.

    1979-04-01

    A high accuracy analogue particle identifier is described. The unit is used for particle identification or data correction of experimental based errors in magnetic spectrometers. Signals which are proportional to the energy, the time-of-flight or the position of absorption of the particles are supplied to an analogue computation circuit (multifunction converter). Three computation functions are available for different applications. The output of the identifier produces correction signals or pulses whose amplitudes are proportional to the mass of the particles. Particle identification and data correction can be optimized by the adjustment of variable parameters. An automatic test unit has been developed for adjustment and routine checking of particle identifiers. The computation functions can be tested by this unit with an accuracy of 1%. (orig.) [de

  7. Acoustic monitoring systems tests at Indian Point Unit 1. Final report

    International Nuclear Information System (INIS)

    Smith, J.R.; Rao, G.V.; Craig, J.

    1979-12-01

    This report describes the results of a program to test acoustic monitoring systems on Indian Point Unit No. 1 under actual plant operating conditions, less the reactor core. The two types of systems evaluated were the monitoring of acoustic emissions generated by growing flaws and the monitoring of acoustic signals from leaks

  8. Closure report for housekeeping category, Corrective Action Unit 349, Area 12, Nevada Test Site

    International Nuclear Information System (INIS)

    1998-01-01

    This Closure Report summarizes the corrective actions which were completed at the Corrective Action Sites within Corrective Action Unit 349 Area 12 at the Nevada Test Site. Current site descriptions, observations and identification of wastes removed are included on FFACO Corrective Action Site housekeeping closure verification forms

  9. Closure report for housekeeping category, Corrective Action Unit 349, Area 12, Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    This Closure Report summarizes the corrective actions which were completed at the Corrective Action Sites within Corrective Action Unit 349 Area 12 at the Nevada Test Site. Current site descriptions, observations and identification of wastes removed are included on FFACO Corrective Action Site housekeeping closure verification forms.

  10. Closure report for housekeeping category, Corrective Action Unit 348, Nevada Test Site

    International Nuclear Information System (INIS)

    1998-01-01

    This Closure Report summarizes the corrective actions which were completed at twelve Corrective Action Sites within Corrective Action Unit 348 at the Nevada Test Site. Current site descriptions, observations and identification of wastes removed are included on FFACO Corrective Action Site housekeeping closure verification forms

  11. Closure report for housekeeping category, Corrective Action Unit 347, Nevada Test Site

    International Nuclear Information System (INIS)

    1998-01-01

    This Closure Report summarizes the corrective actions which were completed at the Corrective Action Sites within Corrective Action Unit 347 at the Nevada Test Site. Current site descriptions, observations and identification of wastes removed are included on FFACO Corrective Action Site housekeeping closure verification forms

  12. Performance and Environmental Test Results of the High Voltage Hall Accelerator Engineering Development Unit

    Science.gov (United States)

    Kamhawi, Hani; Haag, Thomas; Huang, Wensheng; Shastry, Rohit; Pinero, Luis; Peterson, Todd; Mathers, Alex

    2012-01-01

    NASA Science Mission Directorate's In-Space Propulsion Technology Program is sponsoring the development of a 3.5 kW-class engineering development unit Hall thruster for implementation in NASA science and exploration missions. NASA Glenn and Aerojet are developing a high fidelity high voltage Hall accelerator that can achieve specific impulse magnitudes greater than 2,700 seconds and xenon throughput capability in excess of 300 kilograms. Performance, plume mappings, thermal characterization, and vibration tests of the high voltage Hall accelerator engineering development unit have been performed. Performance test results indicated that at 3.9 kW the thruster achieved a total thrust efficiency and specific impulse of 58%, and 2,700 sec, respectively. Thermal characterization tests indicated that the thruster component temperatures were within the prescribed material maximum operating temperature limits during full power thruster operation. Finally, thruster vibration tests indicated that the thruster survived the 3-axes qualification full-level random vibration test series. Pre and post-vibration test performance mappings indicated almost identical thruster performance. Finally, an update on the development progress of a power processing unit and a xenon feed system is provided.

  13. Pilot-scale treatability test plan for the 100-HR-3 operable unit

    International Nuclear Information System (INIS)

    1994-08-01

    This document presents the treatability test plan for pilot-scale pump-and-treat testing at the 100-HR-3 Operable Unit. The test will be conducted in fulfillment of interim Milestone M-15-06E to begin pilot-scale pump-and-treat operations by August 1994. The scope of the test was determined based on the results of lab/bench-scale tests (WHC 1993a) conducted in fulfillment of Milestone M-15-06B. These milestones were established per agreement between the U.S. Department of Energy (DOE), the Washington State Department of Ecology and the U.S. Environmental Protection Agency (EPA), and documented on Hanford Federal of Ecology Facility Agreement and Consent Order Change Control Form M-15-93-02. This test plan discusses a pilot-scale pump-and-treat test for the chromium plume associated with the D Reactor portion of the 100-HR-3 Operable Unit. Data will be collected during the pilot test to assess the effectiveness, operating parameters, and resource needs of the ion exchange (IX) pump-and-treat system. The test will provide information to assess the ability to remove contaminants by extracting groundwater from wells and treating extracted groundwater using IX. Bench-scale tests were conducted previously in which chromium VI was identified as the primary contaminant of concern in the 100-D reactor plume. The DOWEX 21K trademark resin was recommended for pilot-scale testing of an IX pump-and-treat system. The bench-scale test demonstrated that the system could remove chromium VI from groundwater to concentrations less than 50 ppb. The test also identified process parameters to monitor during pilot-scale testing. Water will be re-injected into the plume using wells outside the zone of influence and upgradient of the extraction well

  14. Parents' experiences with neonatal home care following initial care in the neonatal intensive care unit: a phenomenological hermeneutical interview study.

    Science.gov (United States)

    Dellenmark-Blom, Michaela; Wigert, Helena

    2014-03-01

    A descriptive study of parents' experiences with neonatal home care following initial care in the neonatal intensive care unit. As survival rates improve among premature and critically ill infants with an increased risk of morbidity, parents' responsibilities for neonatal care grow in scope and degree under the banner of family-centred care. Concurrent with medical advances, new questions arise about the role of parents and the experience of being provided neonatal care at home. An interview study with a phenomenological hermeneutic approach. Parents from a Swedish neonatal (n = 22) home care setting were extensively interviewed within one year of discharge. Data were collected during 2011-2012. The main theme of the findings is that parents experience neonatal home care as an inner emotional journey, from having a child to being a parent. This finding derives from three themes: the parents' experience of leaving the hospital milieu in favour of establishing independent parenthood, maturing as a parent and processing experiences during the period of neonatal intensive care. This study suggests that neonatal home care is experienced as a care structure adjusted to incorporate parents' needs following discharge from a neonatal intensive care unit. Neonatal home care appears to bridge the gap between hospital and home, supporting the family's adaptation to life in the home setting. Parents become empowered to be primary caregivers, having nurse consultants serving the needs of the whole family. Neonatal home care may therefore be understood as the implementation of family-centred care during the transition from NICU to home. © 2013 John Wiley & Sons Ltd.

  15. Feasibility and efficacy of sepsis management guidelines in a pediatric intensive care unit in Saudi Arabia: a quality improvement initiative.

    Science.gov (United States)

    Hasan, Gamal M; Al-Eyadhy, Ayman A; Temsah, Mohamed-Hani A; Al-Haboob, Ali A; Alkhateeb, Mohammad A; Al-Sohime, Fahad

    2018-04-25

    Evaluation of feasibility and effectiveness of Surviving Sepsis Campaign (SSC) Guidelines implementation at a Pediatric Intensive Care Unit (PICU) in Saudi Arabia to reduce severe sepsis associated mortality. Retrospective data analysis for a prospective quality improvement (QI) initiative. PICU at King Saud University Medical City, Saudi Arabia. Children ≤14 years of age admitted to the PICU from July 2010 to March 2011 with suspected or proven sepsis. Comparisons were made to a previously admitted group of patients with sepsis from October 2009 to June 2010. Adaptation and implementation of the Surviving Sepsis Campaign-Clinical Practice Guidelines (SSC-CPGs) through AGREE instrument and ADAPTE process. We reported pre- and post-implementation outcome of interest for this QI initiative, annual sepsis-related mortality rate. Furthermore, we reported follow-up of annual mortality rate until December 2016. Sixty-five patients was included in the study (42 in post-guidelines implementation group and 23 in pre-guidelines implementation group). Mortality was insignificantly lower in the post-implementation group (26.2% vs. 47.8%; P = 0.079). However, when adjusted for severity, identified by number of failing organs in the multivariate regression analysis, the mortality difference was favorable for the post-implementation group (P = 0.006). The lower sepsis-related mortality rate was also sustained, with an average mortality rate of 15.11% for the subsequent years (2012-16). Adaptation and implementation of SSC Guidelines in our setting support its feasibility and potential benefits. However, a larger study is recommended to explore detailed compliance rates.

  16. 40 CFR 63.5991 - By what date must I conduct an initial compliance demonstration or performance test?

    Science.gov (United States)

    2010-07-01

    ... compliance demonstration or performance test? 63.5991 Section 63.5991 Protection of Environment ENVIRONMENTAL... POLLUTANTS FOR SOURCE CATEGORIES National Emissions Standards for Hazardous Air Pollutants: Rubber Tire... initial compliance demonstration or performance test? (a) If you have a new or reconstructed affected...

  17. Thermionic system evaluation test (TSET) facility construction: A United States and Russian effort

    International Nuclear Information System (INIS)

    Wold, S.K.

    1993-01-01

    The Thermionic System Evaluation Test (TSET) is a ground test of an unfueled Russian TOPAZ-II in-core thermionic space reactor powered by electric heaters. The facility that will be used for testing of the TOPAZ-II systems is located at the New Mexico Engineering Research Institute (NMERI) complex in Albuquerque, NM. The reassembly of the Russian test equipment is the responsibility of International Scientific Products (ISP), a San Jose, CA, company and Inertek, a Russian corporation, with support provided by engineers and technicians from Phillips Laboratory (PL), Sandia National Laboratories (SNL), Los Alamos National Laboratory (LANL), and the University of New Mexico (UNM). This test is the first test to be performed under the New Mexico Strategic Alliance agreement. This alliance consists of the PL, SNL, LANL, and UNM. The testing is being funded by the Strategic Defense Initiative Organization (SDIO) with the PL responsible for project execution

  18. Does provider-initiated HIV testing and counselling lead to higher HIV testing rate and HIV case finding in Rwandan clinics?

    NARCIS (Netherlands)

    Kayigamba, Felix R.; van Santen, Daniëla; Bakker, Mirjam I.; Lammers, Judith; Mugisha, Veronicah; Bagiruwigize, Emmanuel; de Naeyer, Ludwig; Asiimwe, Anita; Schim van der Loeff, Maarten F.

    2016-01-01

    Provider-initiated HIV testing and counselling (PITC) is promoted as a means to increase HIV case finding. We assessed the effectiveness of PITC to increase HIV testing rate and HIV case finding among outpatients in Rwandan health facilities (HF). PITC was introduced in six HFs in 2009-2010. HIV

  19. Comparing Global Initiative for Asthma (GINA) criteria with the Childhood Asthma Control Test (C-ACT) and Asthma Control Test (ACT)

    NARCIS (Netherlands)

    Koolen, B.B.; Pijnenburg, M.W.; Brackel, H.J.; Landstra, A.M.; Berg, N.J. van den; Merkus, P.J.F.M.; Hop, W.C.J.; Vaessen-Verberne, A.A.

    2011-01-01

    Several tools are useful in detecting uncontrolled asthma in children. The aim of this study was to compare Global Initiative for Asthma (GINA) guidelines with the Childhood Asthma Control Test (C-ACT) and the Asthma Control Test (ACT) in detecting uncontrolled asthma in children. 145 children with

  20. 40 CFR Table 26 to Subpart Uuu of... - Initial Compliance With Inorganic HAP Emission Limits for Catalytic Reforming Units

    Science.gov (United States)

    2010-07-01

    ... Emission Limits for Catalytic Reforming Units 26 Table 26 to Subpart UUU of Part 63 Protection of... Pollutants for Petroleum Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery... HAP Emission Limits for Catalytic Reforming Units As stated in § 63.1567(b)(4), you shall meet each...

  1. Unit and integration testing of Lustre programs: a case study from the nuclear industry

    International Nuclear Information System (INIS)

    Thevenod-Fosse, P.

    1998-01-01

    LUSTRE belongs to the class of synchronous data flow languages which have been designed for programming reactive and real-time systems having safety-critical requirements. It is implemented in the SCADE tool. SCADE is a software development environment for real-time systems which consists of a graphical and textual editor, and a C code generator. In previous work, a testing approach specific to LUSTRE programs has been defined, which may be applied at either the unit or integration testing levels of a gradual testing process. The paper reports on an industrial case study we have performed to exemplify the feasibility of the testing strategy. The software module, called SRIC (Source Range Instrumentation channel), was developed by SCHNEIDER ELECTRIC in the SCADE environment. SRIC is extracted from a monitoring software system of a nuclear reactor: it approximates 2600 lines of C code automatically generated by SCADE. Section 2 outlines the testing strategy. Then, Section 3 presents the results related to the program SRIC, for which four testing levels were defined (unit testing followed by three successive integration testing levels). First conclusions and direction for future work are proposed in Section 4. (author)

  2. Unit Root Testing and Estimation in Nonlinear ESTAR Models with Normal and Non-Normal Errors.

    Directory of Open Access Journals (Sweden)

    Umair Khalil

    Full Text Available Exponential Smooth Transition Autoregressive (ESTAR models can capture non-linear adjustment of the deviations from equilibrium conditions which may explain the economic behavior of many variables that appear non stationary from a linear viewpoint. Many researchers employ the Kapetanios test which has a unit root as the null and a stationary nonlinear model as the alternative. However this test statistics is based on the assumption of normally distributed errors in the DGP. Cook has analyzed the size of the nonlinear unit root of this test in the presence of heavy-tailed innovation process and obtained the critical values for both finite variance and infinite variance cases. However the test statistics of Cook are oversized. It has been found by researchers that using conventional tests is dangerous though the best performance among these is a HCCME. The over sizing for LM tests can be reduced by employing fixed design wild bootstrap remedies which provide a valuable alternative to the conventional tests. In this paper the size of the Kapetanios test statistic employing hetroscedastic consistent covariance matrices has been derived and the results are reported for various sample sizes in which size distortion is reduced. The properties for estimates of ESTAR models have been investigated when errors are assumed non-normal. We compare the results obtained through the fitting of nonlinear least square with that of the quantile regression fitting in the presence of outliers and the error distribution was considered to be from t-distribution for various sample sizes.

  3. Nuclear waste transportation package testing: A review of selected programs in the United States and abroad

    International Nuclear Information System (INIS)

    Snedeker, D.F.

    1990-12-01

    This report provides an overview of some recent nuclear waste transportation package development programs. This information is intended to aid the State of Nevada in its review of US Department of Energy (DOE) nuclear waste transportation programs. This report addresses cask testing programs in the United Kingdom and selected 1/4 and full scale testing in the US. Facilities that can provide cask testing services, both in the US and to a limited extent abroad, are identified. The costs for different type test programs are identified as a means to estimate costs for future test programs. Not addressed is the public impact such testing might have in providing an increased sense of safety or confidence. The British test program was apparently quite successful in demonstrating safety to the public at the time. There is no US test effort that is similar in scope for direct comparison. Also addressed are lessons learned from testing programs and areas that may merit possible future integrated examination. Areas that may require further examination are both technical and institutional. This report provides information which, when combined with other sources of information will enable the State of Nevada to assess the following areas: feasibility of full scale testing; costs of full scale tests; potential benefits of testing; limits that full scale testing impose; and disadvantages of emphasis on testing vs analytical solutions. This assessment will then allow the state to comment on DOE Office of Civilian Radioactive Waste Management (OCRWM) plans for the development and licensing of new shipping cask designs. These plans currently expect contractors to perform engineering testing for materials development, quarter scale model testing to validate analytical assessments and full scale prototype testing of operational features. DOE currently plans no full scale or extra-regulatory destructive testing to aid in cask licensing. 1 tab

  4. Use of Ancillary Tests When Determining Brain Death in Pediatric Patients in the United States.

    Science.gov (United States)

    Lewis, Ariane; Adams, Nellie; Chopra, Arun; Kirschen, Matthew P

    2017-10-01

    Although pediatric brain death guidelines stipulate when ancillary testing should be used during brain death determination, little is known about the way these recommendations are implemented in clinical practice. We conducted a survey of pediatric intensivists and neurologists in the United States on the use of ancillary testing. Although most respondents noted they only performed an ancillary test if the clinical examination and apnea test could not be completed, 20% of 195 respondents performed an ancillary test for other reasons, including (1) to convince a family that objected to the brain death determination that a patient is truly dead (n = 21), (2) personal preference (n = 14), and (3) institutional requirement (n = 5). Our findings suggest that pediatricians use ancillary tests for a variety of reasons during brain death determination. Medical societies and governmental regulatory bodies must reinforce the need for homogeneity in practice.

  5. Integrated safeguards testing laboratories in support of the advanced fuel cycle initiative

    International Nuclear Information System (INIS)

    Santi, Peter A.; Demuth, Scott F.; Klasky, Kristen L.; Lee, Haeok; Miller, Michael C.; Sprinkle, James K.; Tobin, Stephen J.; Williams, Bradley

    2009-01-01

    A key enabler for advanced fuel cycle safeguards research and technology development for programs such as the Advanced Fuel Cycle Initiative (AFCI) is access to facilities and nuclear materials. This access is necessary in many cases in order to ensure that advanced safeguards techniques and technologies meet the measurement needs for which they were designed. One such crucial facility is a hot cell based laboratory which would allow developers from universities, national laboratories, and commercial companies to perform iterative research and development of advanced safeguards instrumentation under realistic operating conditions but not be subject to production schedule limitations. The need for such a facility arises from the requirement to accurately measure minor actinide and/or fission product bearing nuclear materials that cannot be adequately shielded in glove boxes. With the contraction of the DOE nuclear complex following the end of the cold war, many suitable facilities at DOE sites are increasingly costly to operate and are being evaluated for closure. A hot cell based laboratory that allowed developers to install and remove instrumentation from the hot cell would allow for both risk mitigation and performance optimization of the instrumentation prior to fielding equipment in facilities where maintenance and repair of the instrumentation is difficult or impossible. These benefits are accomplished by providing developers the opportunity to iterate between testing the performance of the instrumentation by measuring realistic types and amounts of nuclear material, and adjusting and refining the instrumentation based on the results of these measurements. In this paper, we review the requirements for such a facility using the Wing 9 hot cells in the Los Alamos National Laboratory's Chemistry and Metallurgy Research facility as a model for such a facility and describe recent use of these hot cells in support of AFCI.

  6. Parental feeding practices in Mexican American families: initial test of an expanded measure

    Science.gov (United States)

    2013-01-01

    Background Although obesity rates are high among Latino children, relatively few studies of parental feeding practices have examined Latino families as a separate group. Culturally-based approaches to measurement development can begin to identify parental feeding practices in specific cultural groups. This study used qualitative and quantitative methods to develop and test the Parental Feeding Practices (PFP) Questionnaire for use with Mexican American parents. Items reflected both parent’s use of control over child eating and child-centered feeding practices. Methods In the qualitative phase of the research, 35 Latino parents participated in focus groups. Items for the PFP were developed from focus group discussions, as well as adapted from existing parent feeding practice measures. Cognitive interviews were conducted with 37 adults to evaluate items. In the quantitative phase, mothers and fathers of 174 Mexican American children ages 8–10 completed the PFP and provided demographic information. Anthropometric measures were obtained on family members. Results Confirmatory factor analyses identified four parental feeding practice dimensions: positive involvement in child eating, pressure to eat, use of food to control behavior, and restriction of amount of food. Factorial invariance modeling suggested equivalent factor meaning and item response scaling across mothers and fathers. Mothers and fathers differed somewhat in their use of feeding practices. All four feeding practices were related to child body mass index (BMI) percentiles, for one or both parents. Mothers reporting more positive involvement had children with lower BMI percentiles. Parents using more pressure to eat had children with lower BMI percentiles, while parents using more restriction had children with higher BMI percentiles. Fathers using food to control behavior had children with lower BMI percentiles. Conclusions Results indicate good initial validity and reliability for the PFP. It can be

  7. Integrated safeguards testing laboratories in support of the advanced fuel cycle initiative

    Energy Technology Data Exchange (ETDEWEB)

    Santi, Peter A [Los Alamos National Laboratory; Demuth, Scott F [Los Alamos National Laboratory; Klasky, Kristen L [Los Alamos National Laboratory; Lee, Haeok [Los Alamos National Laboratory; Miller, Michael C [Los Alamos National Laboratory; Sprinkle, James K [Los Alamos National Laboratory; Tobin, Stephen J [Los Alamos National Laboratory; Williams, Bradley [DOE, NE

    2009-01-01

    A key enabler for advanced fuel cycle safeguards research and technology development for programs such as the Advanced Fuel Cycle Initiative (AFCI) is access to facilities and nuclear materials. This access is necessary in many cases in order to ensure that advanced safeguards techniques and technologies meet the measurement needs for which they were designed. One such crucial facility is a hot cell based laboratory which would allow developers from universities, national laboratories, and commercial companies to perform iterative research and development of advanced safeguards instrumentation under realistic operating conditions but not be subject to production schedule limitations. The need for such a facility arises from the requirement to accurately measure minor actinide and/or fission product bearing nuclear materials that cannot be adequately shielded in glove boxes. With the contraction of the DOE nuclear complex following the end of the cold war, many suitable facilities at DOE sites are increasingly costly to operate and are being evaluated for closure. A hot cell based laboratory that allowed developers to install and remove instrumentation from the hot cell would allow for both risk mitigation and performance optimization of the instrumentation prior to fielding equipment in facilities where maintenance and repair of the instrumentation is difficult or impossible. These benefits are accomplished by providing developers the opportunity to iterate between testing the performance of the instrumentation by measuring realistic types and amounts of nuclear material, and adjusting and refining the instrumentation based on the results of these measurements. In this paper, we review the requirements for such a facility using the Wing 9 hot cells in the Los Alamos National Laboratory's Chemistry and Metallurgy Research facility as a model for such a facility and describe recent use of these hot cells in support of AFCI.

  8. Parental feeding practices in Mexican American families: initial test of an expanded measure

    Directory of Open Access Journals (Sweden)

    Tschann Jeanne M

    2013-01-01

    Full Text Available Abstract Background Although obesity rates are high among Latino children, relatively few studies of parental feeding practices have examined Latino families as a separate group. Culturally-based approaches to measurement development can begin to identify parental feeding practices in specific cultural groups. This study used qualitative and quantitative methods to develop and test the Parental Feeding Practices (PFP Questionnaire for use with Mexican American parents. Items reflected both parent’s use of control over child eating and child-centered feeding practices. Methods In the qualitative phase of the research, 35 Latino parents participated in focus groups. Items for the PFP were developed from focus group discussions, as well as adapted from existing parent feeding practice measures. Cognitive interviews were conducted with 37 adults to evaluate items. In the quantitative phase, mothers and fathers of 174 Mexican American children ages 8–10 completed the PFP and provided demographic information. Anthropometric measures were obtained on family members. Results Confirmatory factor analyses identified four parental feeding practice dimensions: positive involvement in child eating, pressure to eat, use of food to control behavior, and restriction of amount of food. Factorial invariance modeling suggested equivalent factor meaning and item response scaling across mothers and fathers. Mothers and fathers differed somewhat in their use of feeding practices. All four feeding practices were related to child body mass index (BMI percentiles, for one or both parents. Mothers reporting more positive involvement had children with lower BMI percentiles. Parents using more pressure to eat had children with lower BMI percentiles, while parents using more restriction had children with higher BMI percentiles. Fathers using food to control behavior had children with lower BMI percentiles. Conclusions Results indicate good initial validity and

  9. A Mononuclear Iron-Dependent Methyltransferase Catalyzes Initial Steps in Assembly of the Apratoxin A Polyketide Starter Unit.

    Science.gov (United States)

    Skiba, Meredith A; Sikkema, Andrew P; Moss, Nathan A; Tran, Collin L; Sturgis, Rebecca M; Gerwick, Lena; Gerwick, William H; Sherman, David H; Smith, Janet L

    2017-12-15

    Natural product biosynthetic pathways contain a plethora of enzymatic tools to carry out difficult biosynthetic transformations. Here, we discover an unusual mononuclear iron-dependent methyltransferase that acts in the initiation steps of apratoxin A biosynthesis (AprA MT1). Fe 3+ -replete AprA MT1 catalyzes one or two methyl transfer reactions on the substrate malonyl-ACP (acyl carrier protein), whereas Co 2+ , Fe 2+ , Mn 2+ , and Ni 2+ support only a single methyl transfer. MT1 homologues exist within the "GNAT" (GCN5-related N-acetyltransferase) loading modules of several modular biosynthetic pathways with propionyl, isobutyryl, or pivaloyl starter units. GNAT domains are thought to catalyze decarboxylation of malonyl-CoA and acetyl transfer to a carrier protein. In AprA, the GNAT domain lacks both decarboxylation and acyl transfer activity. A crystal structure of the AprA MT1-GNAT di-domain with bound Mn 2+ , malonate, and the methyl donor S-adenosylmethionine (SAM) reveals that the malonyl substrate is a bidentate metal ligand, indicating that the metal acts as a Lewis acid to promote methylation of the malonyl α-carbon. The GNAT domain is truncated relative to functional homologues. These results afford an expanded understanding of MT1-GNAT structure and activity and permit the functional annotation of homologous GNAT loading modules both with and without methyltransferases, additionally revealing their rapid evolutionary adaptation in different biosynthetic contexts.

  10. MRP-227 Reactor vessel internals inspection planning and initial results at the Oconee nuclear station unit 2

    International Nuclear Information System (INIS)

    Davidsaver, S.B.; Fyfitch, S.; Whitaker, D.E.; Doss, R.L.

    2015-01-01

    The U.S. PWR industry has pro-actively developed generic inspection requirements and standards for reactor vessel (RV) internals. The Electric Power Research Institute (EPRI) Pressurized Water Reactor (PWR) Materials Reliability Program (MRP) has issued MRP-227-A and MRP-228 with mandatory and needed requirements based on the Nuclear Energy Institute (NEI) document NEI 03-08. The inspection and evaluation guidelines contained in MRP-227-A consider eight age-related degradation mechanisms: stress corrosion cracking (SCC), irradiation-assisted stress corrosion cracking (IASCC), wear, fatigue, thermal aging embrittlement, irradiation embrittlement, void swelling and irradiation growth, and thermal and irradiation-enhanced stress relaxation or irradiation-enhanced creep. This paper will discuss the decision planning efforts required for implementing the MRP-227-A and MRP-228 requirements and the results of these initial inspections at the Oconee Nuclear power station (ONS) units. Duke Energy and AREVA overcame a significant technology and NDE challenge by successfully completing the first-of-a-kind MRP-227-A scope requirements at ONS-1 in one outage below the estimated dose and with zero safety issues or events. This performance was repeated at ONS-2 a year later. The remote NDE tooling and processes developed to examine the MRP-227-A scope for ONS-1 and ONS-2 are transferable to other PWRs

  11. Transport processes associated with the initial elevated concentrations of Chernobyl radioactivity in surface air in the United States

    International Nuclear Information System (INIS)

    Larsen, R.J.; Haagenson, P.L.; Reiss, N.M.

    1989-01-01

    Elevated concentrations of radioactivity from the Chernobyl accident were encountered in the surface air over the United States along the east coast and in the north-west on 9 and 10 May 1986. The nearly simultaneous arrival of radioactive debris at widely separated locations resulted from different paths being taken by the debris released at different times during the course of the accident. Debris released during the explosion at the Chernobyl reactor was transported across the Arctic, within the lower troposphere, and zonally across Asia and the North Pacific Ocean, within the mid-troposphere. This debris descended into the planetary boundary layer along the east coast of the US. The descent was associated with a quasi-stationary cyclone located over the western North Atlantic Ocean. Debris that had a different composition of radioactivity was released from the damaged reactor during the week immediately following the initial explosion. This debris was then transported zonally across Asia and the North Pacific Ocean within the planetary boundary layer and lower troposphere and was swept into the north-western US. (author)

  12. The Trilateral Initiative: IAEA Verification of Weapon-Origin Plutonium in the Russian Federation and the United States

    International Nuclear Information System (INIS)

    Shea, T.E.

    2015-01-01

    One year following the indefinite extension of the NPT, the IAEA, the United States and the Russian Federation entered into a cooperative effort aimed at creating a verification system under which the IAEA could accept and monitor nuclear warheads or nuclear warhead components in relation to the Article VI commitments of both States. Over a six year period, through 98 trilateral events, substantial progress was made on verification arrangements and technologies that could enable the IAEA to carry out such a mission, without gaining access to design or manufacturing secrets associated with nuclear weapons. Substantial progress was made on defining the approaches at lead facilities in the two States. The Board of Governors was looking forward to having the Agency undertake such a mission, and the 2000 NPT Review Conference called for the completion and implementation of the Trilateral Initiative. Then elections changed the leadership in both States and the incoming Administrations decided to end the effort, call it a success, and walk away. This presentation will summarize the creation, history, accomplishments, unresolved issues, consider the legacy and suggest four steps that might now be taken. (author)

  13. Quality Improvement Initiative to Reduce Pediatric Intensive Care Unit Noise Pollution With the Use of a Pediatric Delirium Bundle.

    Science.gov (United States)

    Kawai, Yu; Weatherhead, Jeffrey R; Traube, Chani; Owens, Tonie A; Shaw, Brenda E; Fraser, Erin J; Scott, Annette M; Wojczynski, Melody R; Slaman, Kristen L; Cassidy, Patty M; Baker, Laura A; Shellhaas, Renee A; Dahmer, Mary K; Shever, Leah L; Malas, Nasuh M; Niedner, Matthew F

    2017-01-01

    Noise pollution in pediatric intensive care units (PICU) contributes to poor sleep and may increase risk of developing delirium. The Environmental Protection Agency (EPA) recommends noise pollution, to develop a delirium bundle targeted at reducing noise, and to assess the effect of the bundle on nocturnal noise pollution. This is a QI initiative at an academic PICU. Thirty-five sound sensors were installed in patient bed spaces, hallways, and common areas. The pediatric delirium bundle was implemented in 8 pilot patients (40 patient ICU days) while 108 non-pilot patients received usual care over a 28-day period. A total of 20,609 hourly dB readings were collected. Hourly minimum, average, and maximum dB of all occupied bed spaces demonstrated medians [interquartile range] of 48.0 [39.0-53.0], 52.8 [48.1-56.2] and 67.0 [63.5-70.5] dB, respectively. Bed spaces were louder during the day (10AM to 4PM) than at night (11PM to 5AM) (53.5 [49.0-56.8] vs. 51.3 [46.0-55.3] dB, P noise pollution exists in our PICU, and utilizing the pediatric delirium bundle led to a significant noise reduction that can be perceived as half the loudness with hourly nighttime average dB meeting the EPA standards when compliant with the bundle.

  14. Cosmo Cassette: A Microfluidic Microgravity Microbial System For Synthetic Biology Unit Tests and Satellite Missions

    Science.gov (United States)

    Berliner, Aaron J.

    2013-01-01

    Although methods in the design-build-test life cycle of the synthetic biology field have grown rapidly, the expansion has been non-uniform. The design and build stages in development have seen innovations in the form of biological CAD and more efficient means for building DNA, RNA, and other biological constructs. The testing phase of the cycle remains in need of innovation. Presented will be both a theoretical abstraction of biological measurement and a practical demonstration of a microfluidics-based platform for characterizing synthetic biological phenomena. Such a platform demonstrates a design of additive manufacturing (3D printing) for construction of a microbial fuel cell (MFC) to be used in experiments carried out in space. First, the biocompatibility of the polypropylene chassis will be demonstrated. The novel MFCs will be cheaper, and faster to make and iterate through designs. The novel design will contain a manifold switchingdistribution system and an integrated in-chip set of reagent reservoirs fabricated via 3D printing. The automated nature of the 3D printing yields itself to higher resolution switching valves and leads to smaller sized payloads, lower cost, reduced power and a standardized platform for synthetic biology unit tests on Earth and in space. It will be demonstrated that the application of unit testing in synthetic biology will lead to the automatic construction and validation of desired constructs. Unit testing methodologies offer benefits of preemptive problem identification, change of facility, simplicity of integration, ease of documentation, and separation of interface from implementation, and automated design.

  15. Convergence Hypothesis: Evidence from Panel Unit Root Test with Spatial Dependence

    Directory of Open Access Journals (Sweden)

    Lezheng Liu

    2006-10-01

    Full Text Available In this paper we test the convergence hypothesis by using a revised 4- step procedure of panel unit root test suggested by Evans and Karras (1996. We use data on output for 24 OECD countries over 40 years long. Whether the convergence, if any, is conditional or absolute is also examined. According to a proposition by Baltagi, Bresson, and Pirotte (2005, we incorporate spatial autoregressive error into a fixedeffect panel model to account for not only the heterogeneous panel structure, but also spatial dependence, which might induce lower statistical power of conventional panel unit root test. Our empirical results indicate that output is converging among OECD countries. However, convergence is characterized as conditional. The results also report a relatively lower convergent speed compared to conventional panel studies.

  16. Application tests of a new-type LNG rapid gasification unit

    Directory of Open Access Journals (Sweden)

    Ping Yan

    2017-01-01

    Full Text Available Liquefied natural gas (LNG is stored under low temperature and high pressure. It has to be gasified before it is used. Therefore, LNG gasification unit is essential and it is vital to the high-efficiency utilization of LNG. In this paper, a new-type LNG rapid gasification unit was developed. Adopted in this unit are some innovative technologies authorized with the national patent of invention, such as the umbrella-shape gas flow circle unit, the flue gas circulation system and the water feeding system, which help to guarantee its operation safety and increase its operation efficiency. After it was justified in lab test, the unit for industrial application was designed and manufactured and then tested to verify its design rationality. The results show that the new-type LNG rapid gasification unit meets the design requirements in the aspect of efficiency, exhaust gas loss, radiation loss and fuel gas consumption rate; at a load of 1800–2200 m3/h, its efficiency is over 95%; at a load of 1976.0 m3/h which is close to the design value of 2000 m3/h, its efficiency is 96.34% or even up to 2800 m3/h. This new-type LNG rapid gasification unit is adaptable to a large range of loads and can adapt to the rapid increase of external load. Its fuel gas consumption rate is only 1.5%, which is in the range of energy conservation. It presents the advantages of high heating efficiency, rapid startup, high gasification rate, compact structure, small land occupation and invulnerability to the environment, therefore, it is applicable to the middle and small independent regions which cannot be connected to the natural gas supply pipeline networks due to various reasons.

  17. Is Current Account of Turkey Sustainable ? Evidence from Nonlinear Unit Root Tests

    Directory of Open Access Journals (Sweden)

    Serkan Taştan

    2015-09-01

    Full Text Available In this paper, current account sustainability of Turkey is analyzed in a nonlinear framework. Various nonlinear unit root tests have been used to test for structural break, sign and size nonlinearity. We have tested structural break and size nonlinearity separately and structural break-sign and size-sign nonlinearities simultaneously. Only considering the size nonlinearity, we have found that the current account of Turkey is sustainable. Thus, the size nonlinearity, in other words the speed of reversion to equilibrium, is essential for the current account sustainability of Turkey. We have also found that the speed of adjustment towards equilibrium is symmetric, while considering size and sign nonlinearities simultaneously.

  18. Tests of the 30-MJ superconducting magnetic-energy storage unit

    International Nuclear Information System (INIS)

    Boenig, H.J.; Dean, J.W.; Rogers, J.D.; Schermer, R.I.; Hauer, J.F.

    1983-01-01

    A 30-MJ (8.4 kWh) superconducting magnetic energy storage (SMES) unit with a 10-MW converter was installed during the later months of 1982 at the Bonneville Power Administration (BPA) Tacoma substation in Tacoma, Washington. The unit, which is capable of absorbing and releasing up to 10 MJ of energy at a frequency of 0.35 Hz, was designed to damp the dominant power swing mode of the Pacific AC Intertie. Extensive tests were performed with the unit during the first half of 1983. This paper will review the major components of the storage unit and describe the startup and steady state operating experience with the coil, dewar, refrigerator and converter. The unit has absorbed power up to a level of 11.8 Mw. Real power was modulated following a sinusoidal power demand with frequencies from 0.1 to 1.2 Hz and a power level up to +- 8.3 MW. The unit has performed in accordance with design expectations and no major problems have developed

  19. CLOSURE REPORT FOR CORRECTIVE ACTION UNIT 204: STORAGE BUNKERS, NEVADA TEST SITE, NEVADA

    International Nuclear Information System (INIS)

    2006-01-01

    Corrective Action Unit (CAU) 330 consists of four Corrective Action Sites (CASs) located in Areas 6, 22, and 23 of the Nevada Test Site (NTS). The unit is listed in the Federal Facility Agreement and Consent Order (FFACO, 1996) as CAU 330: Areas 6, 22, and 23 Tanks and Spill Sites. CAU 330 consists of the following CASs: CAS 06-02-04, Underground Storage Tank (UST) and Piping CAS 22-99-06, Fuel Spill CAS 23-01-02, Large Aboveground Storage Tank (AST) Farm CAS 23-25-05, Asphalt Oil Spill/Tar Release

  20. Safety Assessment for transient event occurred during the ASTS test of Hanbit Unit 2

    International Nuclear Information System (INIS)

    Yang, Changkeun; Kim, Yohan; Ha, Sangjun

    2014-01-01

    Safety Injection has been actuated during the ASTS (Automatic Seismic Trip System) test of Hanbit Unit 2 on Feb. 28, 2014. It could be bad effect on system integrity. KHNP has been performed safety assessment of system for effect of Safety Injection (SI) actuation occurred during the ASTS test of hanbit Unit 2. Stable state of nuclear power plant system has been confirmed according to Safety Injection and reactor trip event occurred during the ASTS test of hanbit Unit 2. In the result of system safety assessment, major variables of nuclear power plant are located in optimal range and not exceed safety limit. It remains nuclear fuel and the integrity of the power plant is in a safe condition were conformed. After ASTS action, thermal elimination has been processed throughout the turbine until turbine signal occurrence because ASTS is connected to M-G set in the present hanbit Unit 2. Therefore, Safety Injection signal has been actuated by rapid reduction of Steam Generator pressure. In this paper, it is concluded that consideration of equipment and setpoint is needed for that Safety Injection has been not occurred under the unnecessary situation. Stable state of nuclear power plant system has been confirmed for Safety Injection and reactor trip event occurred during the ASTS test of hanbit Unit 2. In the result of system safety assessment, major variables of nuclear power plant are located in optimal range and not exceed safety limit. It remains nuclear fuel and the integrity of the plant is in a safe condition were conformed. It is concluded that consideration of equipment and setpoint is needed for that Safety Injection has been not occurred under the unnecessary situation

  1. Unit evaluation at Yucca Mountain, Nevada Test Site: summary report and recommendation

    International Nuclear Information System (INIS)

    Johnstone, J.K.; Peters, R.R.; Gnirk, P.F.

    1984-06-01

    Of the four potential repository units, identified at Yucca Mountain, two potential units the welded, devitrified portions of the Bullfrog and Tram Members of the Crater Flat Tuff are below the water table. The welded, devitrified Topopah Spring Member of the Paintbrush Tuff and the nonwelded, zeolitized Tuffaceous Beds of Calico Hills are above the water table. The results of a study of the four potential repository units are to provide a technical basis for selecting a single target repository unit for future test and evaluation. The unit evaluation studies compared the units rather than provided and absolute assessment. The four ranking evaluation criteria used were: radionuclide isolation time; allowable repository gross thermal loading; excavation stability; and relative economics. Considered the most important of the criteria as well as the most difficult, radionuclide isolation times were estimated using the limited existing data. The allowable repository gross thermal loadings determined from near-field calculations, were nearly the same for all four units. The gross thermal loading supported other criteria by providing the heat source for succeeding thermally related evaluation studies. A large number of studies evaluated excavation stability, including near-field mechanical and thermomechanical finite element code calculations studies. A large number of studies evaluated excavation stability, including near-field mechanical and thermomechanical finite element code calculations, rock matrix property evaluation, and rock mass classification. Relative economics, a minor criterion, did not play an explicit role in the final ranking. Based on all of the analyses, the final recommendation was that the Topopah Springs be selected as the target unit, followed, in order, by the Calico Hills, Bullfrog, and Tram

  2. Phase II Transport Model of Corrective Action Unit 98: Frenchman Flat, Nevada Test Site, Nye County, Nevada, Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Gregg Ruskuaff

    2010-01-01

    This document, the Phase II Frenchman Flat transport report, presents the results of radionuclide transport simulations that incorporate groundwater radionuclide transport model statistical and structural uncertainty, and lead to forecasts of the contaminant boundary (CB) for a set of representative models from an ensemble of possible models. This work, as described in the Federal Facility Agreement and Consent Order (FFACO) Underground Test Area (UGTA) strategy (FFACO, 1996; amended 2010), forms an essential part of the technical basis for subsequent negotiation of the compliance boundary of the Frenchman Flat corrective action unit (CAU) by Nevada Division of Environmental Protection (NDEP) and National Nuclear Security Administration Nevada Site Office (NNSA/NSO). Underground nuclear testing via deep vertical shafts was conducted at the Nevada Test Site (NTS) from 1951 until 1992. The Frenchman Flat area, the subject of this report, was used for seven years, with 10 underground nuclear tests being conducted. The U.S. Department of Energy (DOE), NNSA/NSO initiated the UGTA Project to assess and evaluate the effects of underground nuclear tests on groundwater at the NTS and vicinity through the FFACO (1996, amended 2010). The processes that will be used to complete UGTA corrective actions are described in the “Corrective Action Strategy” in the FFACO Appendix VI, Revision No. 2 (February 20, 2008).

  3. Revision report about the in-situ tests of 1000 MW unit 5 Kozloduy (Bulgaria)

    International Nuclear Information System (INIS)

    Muzzi, F.

    1995-01-01

    This report refers to the technical revision performed on the technical report about the in-situ tests performed on 1000 Unit 5 nuclear power station of Kozloduy (Bulgaria), within the frame of the IAEA benchmark study for the seismic analysis and testing of an existing Nuclear Power Plant. After a foreword to define the aims of the job and the identification of the scope of the work, a brief description of the plant is made. A brief description of the theory about the modal parameter determination and the soil-structure interaction analysis by experimental tests is made. The following chapters collect some comments about the tests carried out in Kozloduy, with special reference to the general correctness of testing procedure and to data special requirements for the seismic safety margin assessment procedures to be applied on the existing power station

  4. Report to the Attorney General on Body Armor Safety Initiative Testing and Activities

    National Research Council Canada - National Science Library

    2005-01-01

    On November 17, 2003, Attorney General John Ashcroft announced the U.S. Department of Justice's Body Armor Safety Initiative in response to concerns from the law enforcement community regarding the effectiveness of body armor in use...

  5. Interpreting the need for initial support to perform tandem stance tests of balance

    NARCIS (Netherlands)

    Hile, E.S.; Brach, J.S.; Perera, S.; Wert, D.M.; VanSwearingen, J.M.; Studenski, S.A.

    2012-01-01

    BACKGROUND: Geriatric rehabilitation reimbursement increasingly requires documented deficits on standardized measures. Tandem stance performance can characterize balance, but protocols are not standardized. Objective The purpose of this study was to explore the impact of: (1) initial support to

  6. Near Earth Asteroid Scout Solar Sail Engineering Development Unit Test Suite

    Science.gov (United States)

    Lockett, Tiffany Russell; Few, Alexander; Wilson, Richard

    2017-01-01

    The Near Earth Asteroid (NEA) Scout project is a 6U reconnaissance mission to investigate a near Earth asteroid utilizing an 86m(sub 2) solar sail as the primary propulsion system. This will be the largest solar sail NASA has launched to date. NEA Scout is currently manifested on the maiden voyage of the Space Launch System in 2018. In development of the solar sail subsystem, design challenges were identified and investigated for packaging within a 6U form factor and deployment in cis-lunar space. Analysis was able to capture understanding of thermal, stress, and dynamics of the stowed system as well as mature an integrated sail membrane model for deployed flight dynamics. Full scale system testing on the ground is the optimal way to demonstrate system robustness, repeatability, and overall performance on a compressed flight schedule. To physically test the system, the team developed a flight sized engineering development unit with design features as close to flight as possible. The test suite included ascent vent, random vibration, functional deployments, thermal vacuum, and full sail deployments. All of these tests contributed towards development of the final flight unit. This paper will address several of the design challenges and lessons learned from the NEA Scout solar sail subsystem engineering development unit. Testing on the component level all the way to the integrated subsystem level. From optical properties of the sail material to fold and spooling the single sail, the team has developed a robust deployment system for the solar sail. The team completed several deployments of the sail system in preparation for flight at half scale (4m) and full scale (6.8m): boom only, half scale sail deployment, and full scale sail deployment. This paper will also address expected and received test results from ascent vent, random vibration, and deployment tests.

  7. The FDA Unapproved Drugs Initiative: An Observational Study of the Consequences for Drug Prices and Shortages in the United States.

    Science.gov (United States)

    Gupta, Ravi; Dhruva, Sanket S; Fox, Erin R; Ross, Joseph S

    2017-10-01

    Hundreds of drug products are currently marketed in the United States without approval from the FDA. The 2006 Unapproved Drugs Initiative (UDI) requires manufacturers to remove these drug products from the market or obtain FDA approval by demonstrating evidence of safety and efficacy. Once the FDA acts against an unapproved drug, fewer manufacturers remain in the market, potentially enabling drug price increases and greater susceptibility to drug shortages. There is a need for systematic study of the UDI's effect on prices and shortages of all targeted drugs. To examine the clinical evidence for approval and association with prices and shortages of previously unapproved prescription drugs after being addressed by the UDI. Previously unapproved prescription drugs that faced UDI regulatory action or with at least 1 product that received FDA approval through manufacturers' voluntary compliance with the UDI between 2006 and 2015 were identified. The clinical evidence was categorized as either newly conducted clinical trials or use of previously published literature and/or bioequivalence studies to demonstrate safety and efficacy. We determined the change in average wholesale price, presence of shortage, and duration of shortage for each drug during the 2 years before and after UDI regulatory action or approval through voluntary compliance. Between 2006 and 2015, 34 previously unapproved prescription drugs were addressed by the UDI. Nearly 90% of those with a drug product that received FDA approval were supported by literature reviews or bioequivalence studies, not new clinical trial evidence. Among the 26 drugs with available pricing data, average wholesale price during the 2 years before and after voluntary approval or UDI action increased by a median of 37% (interquartile range [IQR] = 23%-204%; P Innovation; from the Blue Cross Blue Shield Association to better understand medical technology evidence generation; from the Centers for Medicare & Medicaid Services to

  8. Design and Implementation of the Control System of an Internal Combustion Engine Test Unit

    Directory of Open Access Journals (Sweden)

    Tufan Koç

    2014-02-01

    Full Text Available Accurate tests and performance analysis of engines are required to minimize measurement errors and so the use of the advanced test equipment is imperative. In other words, the reliable test results depend on the measurement of many parameters and recording the experimental data accurately which is depended on engine test unit. This study aims to design the control system of an internal combustion engine test unit. In the study, the performance parameters of an available internal combustion engine have been transferred to computer in real time. A data acquisition (DAQ card has been used to transfer the experimental data to the computer. Also, a user interface has been developed for performing the necessary procedures by using LabVIEW. The dynamometer load, the fuel consumption, and the desired speed can easily be adjusted precisely by using DAQ card and the user interface during the engine test. Load, fuel consumption, and temperature values (the engine inlet-outlet, exhaust inlet-outlet, oil, and environment can be seen on the interface and also these values can be recorded to the computer. It is expected that developed system will contribute both to the education of students and to the researchers’ studies and so it will eliminate a major lack.

  9. Local energy ownership in Europe. An exploratory study of local public initiatives in France, Germany and the United Kingdom

    International Nuclear Information System (INIS)

    Ruedinger, Andreas

    2017-06-01

    Across Europe, a growing number of local authorities are eager to regain control over energy systems on a wide range of scales and modalities. Through an exploratory study authored by Andreas Ruedinger and funded by the French Agency for Energy Management (ADEME), Energy Cities decided to shed light on the various nuances surrounding this phenomenon of local reclaim over energy systems and offer new perspectives to cities wishing to replicate successful initiatives. This European overview focuses mainly on three countries: Germany, which could almost be described as the cradle of re-municipalization, the United Kingdom and France. Local energy management can take many forms, and the study outlines and develops four specific processes: 1. re-municipalization, 2. Political decentralization, 3. Citizen projects, 4. Participatory governance. More and more cities are taking a leading role in driving the energy transition, not only as planning authorities but also as an operational actors, inspired in particular by examples of re-municipalization in the water sector. Whether it is through the creation of new integrated municipal companies such as Germany, public energy suppliers such as the UK, or local operators investing in renewable energy and energy efficiency projects. France, we see the outlines of a movement of re-appropriation of energy transition by local communities, the study finds. The reasons and opportunities that motivate local authorities to embark on re-municipalization projects are multiple: revitalizing the local economy, creating a close connection with citizens, managing local public services in a more integrated way, fostering cooperation and partnerships with other players, accessing new markets, etc. However, as the study points out, these endeavors can also come with some risks, such as the competitive pressure exerted by the private sector and the limited influence over national and European energy policies

  10. Local energy ownership in Europe. An exploratory study of local public initiatives in France, Germany and the United Kingdom

    International Nuclear Information System (INIS)

    Ruedinger, Andreas

    2017-06-01

    Across Europe, a growing number of local authorities are eager to regain control over energy systems on a wide range of scales and modalities. Through an exploratory study authored by Andreas Ruedinger and funded by the French Agency for Energy Management (ADEME), Energy Cities decided to shed light on the various nuances surrounding this phenomenon of local reclaim over energy systems and offer new perspectives to cities wishing to replicate successful initiatives. This European overview focuses mainly on three countries: Germany, which could almost be described as the cradle of re-municipalization, the United Kingdom and France. Local energy management can take many forms, and the study outlines and develops four specific processes: 1. Re-municipalization, 2. Political decentralization, 3. Citizen projects, 4. Participatory governance. More and more cities are taking a leading role in driving the energy transition, not only as planning authorities but also as an operational actors, inspired in particular by examples of re-municipalization in the water sector. Whether it is through the creation of new integrated municipal companies such as Germany, public energy suppliers such as the UK, or local operators investing in renewable energy and energy efficiency projects. France, we see the outlines of a movement of re-appropriation of energy transition by local communities, the study finds. The reasons and opportunities that motivate local authorities to embark on re-municipalization projects are multiple: revitalizing the local economy, creating a close connection with citizens, managing local public services in a more integrated way, fostering cooperation and partnerships with other players, accessing new markets, etc. However, as the study points out, these endeavors can also come with some risks, such as the competitive pressure exerted by the private sector and the limited influence over national and European energy policies

  11. Nuclear Facility Accident (NFAC) Unit Test Report For HPAC Version 6.3

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ronald W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Computational Sciences and Engineering Division; Morris, Robert W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Computational Sciences and Engineering Division; Sulfredge, Charles David [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Computational Sciences and Engineering Division

    2015-12-01

    This is a unit test report for the Nuclear Facility Accident (NFAC) model for the Hazard Prediction and Assessment Capability (HPAC) version 6.3. NFAC’s responsibility as an HPAC component is three-fold. First, it must present an interactive graphical user interface (GUI) by which users can view and edit the definition of an NFAC incident. Second, for each incident defined, NFAC must interact with RTH to create activity table inputs and associate them with pseudo materials to be transported via SCIPUFF. Third, NFAC must create SCIPUFF releases with the associated pseudo materials for transport and dispersion. The goal of NFAC unit testing is to verify that the inputs it produces are correct for the source term or model definition as specified by the user via the GUI.

  12. Nuclear Facility Accident (NFAC) Unit Test Report For HPAC Version 6.3

    International Nuclear Information System (INIS)

    Lee, Ronald W.; Morris, Robert W.; Sulfredge, Charles David

    2015-01-01

    This is a unit test report for the Nuclear Facility Accident (NFAC) model for the Hazard Prediction and Assessment Capability (HPAC) version 6.3. NFAC's responsibility as an HPAC component is three-fold. First, it must present an interactive graphical user interface (GUI) by which users can view and edit the definition of an NFAC incident. Second, for each incident defined, NFAC must interact with RTH to create activity table inputs and associate them with pseudo materials to be transported via SCIPUFF. Third, NFAC must create SCIPUFF releases with the associated pseudo materials for transport and dispersion. The goal of NFAC unit testing is to verify that the inputs it produces are correct for the source term or model definition as specified by the user via the GUI.

  13. Closure Report for Corrective Action Unit 134: Aboveground Storage Tanks, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    2009-01-01

    Corrective Action Unit (CAU) 134 is identified in the Federal Facility Agreement and Consent Order (FFACO) as 'Aboveground Storage Tanks' and consists of the following four Corrective Action Sites (CASs), located in Areas 3, 15, and 29 of the Nevada Test Site: (1) CAS 03-01-03, Aboveground Storage Tank; (2) CAS 03-01-04, Tank; (3) CAS 15-01-05, Aboveground Storage Tank; and (4) CAS 29-01-01, Hydrocarbon Stain

  14. A Bootstrap Neural Network Based Heterogeneous Panel Unit Root Test: Application to Exchange Rates

    OpenAIRE

    Christian de Peretti; Carole Siani; Mario Cerrato

    2010-01-01

    This paper proposes a bootstrap artificial neural network based panel unit root test in a dynamic heterogeneous panel context. An application to a panel of bilateral real exchange rate series with the US Dollar from the 20 major OECD countries is provided to investigate the Purchase Power Parity (PPP). The combination of neural network and bootstrapping significantly changes the findings of the economic study in favour of PPP.

  15. Commissioning tests at Bohunice NPP V1 unit 2 after reconstruction in 1998

    International Nuclear Information System (INIS)

    Pajtinka, A.; Tvaroska, V.; Wiening, K.-H.; Mueller, B.

    2000-01-01

    The last and the most extensive stage in the reconstruction project of the Bohunice NPP started in July 1998. The main activities performed during a 6-month scheduled unit 2 outage included: - Installation of a new emergency core cooling system with an increased capacity according to the defined broader break spectrum for LOCA; - Reconstruction of the existing confinement spray system and installation of a new confinement pressure suppression system; - Completion of upgrading measures to increase the reliability of emergency power supply systems (replacement of low voltage switchgear, installation of new cabling for all loads important to safety, installation of new motor-generators and rectifier sets); - Connection to the plant and commissioning of the new reactor protection system. Comprehensive tests and checks performed on completion of installation work on the modified mechanical, electrical and I and C systems were important reasons for the absence of major problems during restart of the unit after the several project implementation phases. Operating experience at unit 2 since its recommissioning in January 1999 has confirmed that the required safety standards have been met and that operational reliability has been substantially increased at the sometime. Periodic testing is being performed in accordance with the limits and conditions for safe operation of Bohunice NPP. To date all these tests were completed without significant problems. The functions implemented in the new technology met the test program criteria, which were approved with authority, in all essential areas. Through the close cooperation of the partners involved and through the combined efforts of the various engineering and operating disciplines, technical and scheduling problems could be immediately identified and quickly resolved. In general, these kinds of projects require optimum cooperation among the parties involved. Modernization of the NPP Bohunice V1 unit 2 has shown, that all

  16. Technical progress report. Private sector initiatives between the United States and Japan. January 1989 - December 1989; ANNUAL

    International Nuclear Information System (INIS)

    1990-01-01

    This annual report for calendar year 1989 describes the efforts performed under the Private Sector Initiatives contract. The report also describes those efforts that have continued with private funding after being initiated under this contract

  17. Technical progress report. Private sector initiatives between the United States and Japan. January 1991 - December 1991; ANNUAL

    International Nuclear Information System (INIS)

    1993-01-01

    This annual report for calendar year 1991 describes the efforts performed under the Private Sector Initiatives contract. The report also describes those efforts that have continued with private funding after being initiated under this contract

  18. Another Look at the Draft Mil-Std-1540E Unit Random Vibration Test Requirements

    Science.gov (United States)

    Perl, E.; Peterson, A. J..; Davis, D.

    2012-07-01

    The draft Mil-Std-1540E has been updated to reflect lessons learned since its publication as an SMC Standard in 2008, [1], and an earlier Aerospace Corporation Technical Report released in 2006, [2]. This paper discusses the technical rationale supporting some of the unit random vibration test requirements to provide better insight into their derivation and application to programs. It is intended that these requirements be tailored for each program to reflect the customer risk profile. Several tailoring options are provided and a two phase test strategy is discussed to highlight its applicability to utilizing heritage hardware in new applications.

  19. 49 CFR 232.205 - Class I brake test-initial terminal inspection.

    Science.gov (United States)

    2010-10-01

    ... per minute. (ii) Air Flow Method Test. When a locomotive is equipped with a 26-L brake valve or equivalent pressure maintaining locomotive brake valve, a railroad may use the Air Flow Method Test as an... air flow shall not exceed 60 cubic feet per minute (CFM). (i) Leakage Test. The brake pipe leakage...

  20. Counselor Hypothesis Testing Strategies: The Role of Initial Impressions and Self-Schema.

    Science.gov (United States)

    Strohmer, Douglas C.; Chiodo, Anthony L.

    1984-01-01

    Presents two experiments concerning confirmatory bias in the way counselors collect data to test their hypotheses. Counselors were asked either to develop their own clinical hypothesis or were given a hypothesis to test. Confirmatory bias in hypothesis testing was not supported in either experiment. (JAC)